WorldWideScience

Sample records for asce standardized reference

  1. High-resolution global grids of revised Priestley-Taylor and Hargreaves-Samani coefficients for assessing ASCE-standardized reference crop evapotranspiration and solar radiation

    Science.gov (United States)

    Aschonitis, Vassilis G.; Papamichail, Dimitris; Demertzi, Kleoniki; Colombani, Nicolo; Mastrocicco, Micol; Ghirardini, Andrea; Castaldelli, Giuseppe; Fano, Elisa-Anna

    2017-08-01

    The objective of the study is to provide global grids (0.5°) of revised annual coefficients for the Priestley-Taylor (P-T) and Hargreaves-Samani (H-S) evapotranspiration methods after calibration based on the ASCE (American Society of Civil Engineers)-standardized Penman-Monteith method (the ASCE method includes two reference crops: short-clipped grass and tall alfalfa). The analysis also includes the development of a global grid of revised annual coefficients for solar radiation (Rs) estimations using the respective Rs formula of H-S. The analysis was based on global gridded climatic data of the period 1950-2000. The method for deriving annual coefficients of the P-T and H-S methods was based on partial weighted averages (PWAs) of their mean monthly values. This method estimates the annual values considering the amplitude of the parameter under investigation (ETo and Rs) giving more weight to the monthly coefficients of the months with higher ETo values (or Rs values for the case of the H-S radiation formula). The method also eliminates the effect of unreasonably high or low monthly coefficients that may occur during periods where ETo and Rs fall below a specific threshold. The new coefficients were validated based on data from 140 stations located in various climatic zones of the USA and Australia with expanded observations up to 2016. The validation procedure for ETo estimations of the short reference crop showed that the P-T and H-S methods with the new revised coefficients outperformed the standard methods reducing the estimated root mean square error (RMSE) in ETo values by 40 and 25 %, respectively. The estimations of Rs using the H-S formula with revised coefficients reduced the RMSE by 28 % in comparison to the standard H-S formula. Finally, a raster database was built consisting of (a) global maps for the mean monthly ETo values estimated by ASCE-standardized method for both reference crops, (b) global maps for the revised annual coefficients of the P

  2. Comparison of lysimeter based and calculated ASCE reference evapotranspiration in a subhumid climate

    Science.gov (United States)

    Nolz, Reinhard; Cepuder, Peter; Eitzinger, Josef

    2016-04-01

    The standardized form of the well-known FAO Penman-Monteith equation, published by the Environmental and Water Resources Institute of the American Society of Civil Engineers (ASCE-EWRI), is recommended as a standard procedure for calculating reference evapotranspiration (ET ref) and subsequently plant water requirements. Applied and validated under different climatic conditions it generally achieved good results compared to other methods. However, several studies documented deviations between measured and calculated reference evapotranspiration depending on environmental and weather conditions. Therefore, it seems generally advisable to evaluate the model under local environmental conditions. In this study, reference evapotranspiration was determined at a subhumid site in northeastern Austria from 2005 to 2010 using a large weighing lysimeter (ET lys). The measured data were compared with ET ref calculations. Daily values differed slightly during a year, at which ET ref was generally overestimated at small values, whereas it was rather underestimated when ET was large, which is supported also by other studies. In our case, advection of sensible heat proved to have an impact, but it could not explain the differences exclusively. Obviously, there were also other influences, such as seasonal varying surface resistance or albedo. Generally, the ASCE-EWRI equation for daily time steps performed best at average weather conditions. The outcomes should help to correctly interpret ET ref data in the region and in similar environments and improve knowledge on the dynamics of influencing factors causing deviations.

  3. A Comparison of ASCE and FAO56 Reference Evapotranspiration at Different Subdaily Timescales: a Numerical Study

    Directory of Open Access Journals (Sweden)

    Farzin Parchami-Araghi

    2017-01-01

    Full Text Available Introduction: Subdaily estimates of reference evapotranspiration (ETo are needed in many applications such as dynamic agro-hydrological modeling. The ASCE and FAO56 Penman–Monteith models (ASCE-PM and FAO56-PM, respectively has received favorable acceptance and application over much of the world, including the United States, for establishing a reference evapotranspiration (ETo index as a function of weather parameters. In the past several years various studies have evaluated ASCE-PM and FAO56-PM models for calculating the commonest hourly or 15-min ETo either by comparing them with lysimetric measurements or by comparison with one another (2, 3, 5, 9, 10, 11, 16, 17, 19. In this study, sub-daily ET o estimates made by the ASCE-PM and FAO56-PM models at different timescales (1-360 min were compared through conduction of a computational experiment, using a daily to sub-daily disaggregation framework developed by Parchami-Araghi et al. (14. Materials and Methods: Daily and sub-daily weather data at different timescales (1-360 min were generated via a daily-to-sub-daily weather data disaggregation framework developed by Parchami-Araghi et al. (14, using long-term (59 years daily weather data obtained from Abadan synoptic weather station. Daily/sub-daily net long wave radiation (Rnl was estimated through 6 different approaches, including using two different criteria for identifying the daytime/nighttime periods : 1 the standard criteria implemented in both ASCE-PM and FAO56-PM models and 2 criterion of actual time of sunset and sunrise in combination with 1 estimation of clear-sky radiation (Rso based on the standard approach implemented in both ASCE-PM and FAO56-PM models (1st and 2nd Rnl estimation approaches, respectively, 2 integral of the Rso estimates derived via a physically based solar radiation model developed by Yang et al. (25, YNG model, for one-second time-steps (3rd and 4th Rnl estimation approaches, respectively, and 3 integral of

  4. Standard Reference Tables -

    Data.gov (United States)

    Department of Transportation — The Standard Reference Tables (SRT) provide consistent reference data for the various applications that support Flight Standards Service (AFS) business processes and...

  5. Ozone Standard Reference Photometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Standard Reference Photometer (SRP) Program began in the early 1980s as collaboration between NIST and the U.S. Environmental Protection Agency (EPA) to design,...

  6. ASC-1

    DEFF Research Database (Denmark)

    Jakimoski, Goce; Khajuria, Samant

    2011-01-01

    uses leak extraction from diÆerent AES rounds to compute the key material that is XOR-ed with the message to compute the ciphertext. Unlike LEX, the ASC-1 operates in a CFB fashion to compute an authentication tag over the encrypted message. We argue that ASC-1 is secure by reducingits (IND-CCA , INT......The goal of the modes of operation for authenticated encryption is to achieve faster encryption and message authentication by performing both the encryption and the message authentication in a single pass as opposed to the traditional encrypt-then-mac approach, which requires two passes....... Unfortunately, the use of a block cipher as a building block limits the performance of the authenticated encryption schemes to at most one message block per block cipher evaluation. In this paper, we propose the authenticated encryption scheme ASC-1 (Authenticating Stream Cipher One). Similarly to LEX, ASC-1...

  7. Authenticated Secure Container System (ASCS)

    International Nuclear Information System (INIS)

    1991-01-01

    Sandia National Laboratories developed an Authenticated Secure Container System (ASCS) for the International Atomic Energy Agency (IAEA). Agency standard weights and safeguards samples can be stored in the ASCS to provide continuity of knowledge. The ASCS consists of an optically clear cover, a base containing the Authenticated Item Monitoring System (AIMS) transmitter, and the AIMS receiver unit for data collection. The ASCS will provide the Inspector with information concerning the status of the system, during a surveillance period, such as state of health, tampering attempts, and movement of the container system. The secure container is located inside a Glove Box with the receiver located remotely from the Glove Box. AIMS technology uses rf transmission from the secure container to the receiver to provide a record of state of health and tampering. The data is stored in the receiver for analysis by the Inspector during a future inspection visit. 2 refs

  8. Performance Measurement of Advanced Stirling Convertors (ASC-E3)

    Science.gov (United States)

    Oriti, Salvatore M.

    2013-01-01

    NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing data of the Advanced Stirling Convertor (ASC). The latest version of the ASC (ASC-E3, to represent the third cycle of engineering model test hardware) is of a design identical to the forthcoming flight convertors. For this generation of hardware, a joint Sunpower and GRC effort was initiated to improve and standardize the test support hardware. After this effort was completed, the first pair of ASC-E3 units was produced by Sunpower and then delivered to GRC in December 2012. GRC has begun operation of these units. This process included performance verification, which examined the data from various tests to validate the convertor performance to the product specification. Other tests included detailed performance mapping that encompassed the wide range of operating conditions that will exist during a mission. These convertors were then transferred to Lockheed Martin for controller checkout testing. The results of this latest convertor performance verification activity are summarized here.

  9. Revision of ASCE 4

    International Nuclear Information System (INIS)

    Nelson, T.A.; Murray, R.C.; Short, S.A.

    1995-01-01

    The original version of ASCE Standard 4, ''Seismic Analysis of Safety-Related Nuclear Structures'' was published in September 1986. It is ASCE policy to update its standards on a five year interval and the Working Group on Seismic Analysis of Safety Related Nuclear Structures was reconvened to formulate the revisions. The goal in updating the standard is to make sure that it is still relevant and that it incorporates the state of the practice in seismic engineering or, in some cases, where it has been demonstrated that state-of-the-art improvements need to be made to standard practice; new improvements are included. The contents of the new standard cover the same areas as the original version, with some additions. The contents are as follows: Input - response spectra and time histories; modeling of structures; analysis of structures; soil-structure interaction; input for subsystem analysis; special structures - buried pipes and conduits, earth-retaining walls, above-ground vertical tanks, raceways, and base-isolated structures; and an appendix providing seismic probabilistic risk assessment and margin assessment

  10. ASTM reference radiologic digital image standards

    International Nuclear Information System (INIS)

    Wysnewski, R.; Wysnewski, D.

    1996-01-01

    ASTM Reference Radiographs have been essential in defining industry's material defect grade levels for many years. ASTM Reference Radiographs are used extensively as even the American Society for Metals Nondestructive Inspection and Quality Control Metals Handbook, Volume 11, eighth edition refers to ASTM Standard Reference Radiographs. The recently published E 1648 Standard Reference Radiographs for Examination of Aluminum Fusion Welds is a prime example of the on-going need for these references. To date, 14 Standard Reference Radiographs have been published to characterize material defects. Standard Reference Radiographs do not adequately address film-less radiologic methods. There are differences in mediums to content with. On a computer CRT defect indications appear differently when compared to indications viewed in a radiograph on a view box. Industry that uses non-film radiologic methods of inspection can be burdened with additional time and money developing internal standard reference radiologic images. These references may be deemed necessary for grading levels of product defects. Because there are no ASTM Standard Reference Radiologic data files for addressing this need in the industry, the authors of this paper suggested implementing a method for their creation under ASTM supervision. ASTM can assure continuity to those users making the transition from analog radiographic images to digital image data by swiftly addressing the requirements for reference digital image standards. The current status and possible future activities regarding a method to create digital data files is presented in this paper summary

  11. Stellar aberration correction and thermoelastic compensation of Swarm μASC attitude observations: A comment to the Express Letter “Mysterious misalignments between geomagnetic and stellar reference frames seen in CHAMP and Swarm satellite measurements”, by Stefan Maus

    DEFF Research Database (Denmark)

    Herceg, M.; Jørgensen, P. S.; Jørgensen, J. L.

    2017-01-01

    . However, comparison of the Inter Boresight Angle shows a relative attitude variation between the μASC Camera Head Units. These misalignments between Camera Head Units and a geomagnetic reference frame cannot be explained by incorrect aberration correction (as theorized by Maus). Herceg et al. found them...... and clean from any variation caused by thermoelastic effects....

  12. Modification of Displacement Coefficient Method in Estimation of Target Displacement for Regular Concrete Bridges Based on ASCE 41-06 Standard

    Directory of Open Access Journals (Sweden)

    Seyed Bahram Beheshti-Aval

    2015-06-01

    Full Text Available Displacement Coefficient Method (DCM stipulated in the ASCE 41-06 standard is becoming the preferred method for seismic rehabilitation of buildings in many high-seismic-hazard countries. Applications of the method for non-building constructions such as bridges are beyond the scope of this standard. Thus its application to this kind of structure should be approached with care. Target displacement has reasonable accuracy for buildings with strong columns and weak beams, where there is the development of plastic hinges. Due to high stiffness and strength of the deck relative to the piers in most bridges, this mechanism does not occur, and it is necessary to evaluate the accuracy of DCM for such structures. In this research, an attempt is made to evaluate the credibility of DCM in the ASCE/SEI 41-06 standard for estimating target drifts in concrete regular bridges under strong ground motions. To apply the extension of the method to bridge structures, the definition of new correction factor CB, which should be multiplied to previous coefficients, is required. This novel coefficient can improve the accuracy of the mentioned method in accessing seismic displacement demands. The coefficient is presented for soil types A to D based on NEHRP soil classification. The validity of the modified DCM is examined for several bridges with use of nonlinear dynamic analysis. Good correlation is found between both procedures.

  13. Standard digital reference images for titanium castings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The digital reference images provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in titanium castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct digital reference images, which illustrate the discontinuity types and severity levels. They are intended to provide the following: 1.1.1 A guide enabling recognition of titanium casting discontinuities and their differentiation both as to type and degree through digital radiographic examination. 1.1.2 Example digital radiographic illustrations of discontinuities and a nomenclature for reference in acceptance standards, specifications and drawings. 1.2 The digital reference images consist of seventeen digital files each illustrating eight grades of increasing severity. The files illustrate seven common discontinuity types representing casting sections up to 1-in. (25.4-mm). 1.3 The reference radiographs were developed for casting sections up to 1...

  14. Development of standard reference samples for diffractometry

    International Nuclear Information System (INIS)

    Galvao, Antonio de Sant'Ana

    2011-01-01

    In this work, samples of standard reference materials for diffractometry of polycrystals were developed. High-purity materials were submitted to mechanical and thermal treatments in order to present the adequate properties to be used as high-quality standard reference materials for powder diffraction, comparable to the internationally recognized produced by the USA National Institute of Standards and Technology NIST, but at lower costs. The characterization of the standard materials was performed by measurements in conventional X-ray diffraction diffractometers, high resolution neutron diffraction and high-resolution synchrotron diffraction. The lattice parameters were calculated by extrapolation of the values obtained from each X-ray reflection against cos 2 θ by the Least-Squares Method. The adjustments were compared to the values obtained by the Rietveld Method, using program GSAS. The materials thus obtained were the α-alumina, yttrium oxide, silicon, cerium oxide, lanthanum hexaboride and lithium fluoride. The standard reference materials produced present quality similar or, in some cases, superior to the standard reference materials produced and commercialized by the NIST. (author)

  15. 15 CFR 230.3 - New Standard Reference Materials.

    Science.gov (United States)

    2010-01-01

    ... NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE STANDARD REFERENCE MATERIALS STANDARD REFERENCE MATERIALS General Information § 230.3 New Standard Reference Materials. When new SRM's... scientific and trade journals. ...

  16. Practical reference - radiation standards in Canada

    International Nuclear Information System (INIS)

    1983-07-01

    In developing a policy that will require licensees to calibrate their radiation dose measuring devices and trace such calibrations to approved reference standards, the AECB has consulted recognized experts. This document presents the experts' reports and recommendations which will be considered in finalizing the policy

  17. The development of the brake system of the BMW 850i including ABS and ASC. Entwicklung des Bremssystems des BMW 850i einschliesslich ABS und ASC

    Energy Technology Data Exchange (ETDEWEB)

    Kraft, H.J.; Leffler, H.

    1990-02-01

    The brake system of the new BMW 850i is described in the following. The brake actuation takes place via an hydraulic brake booster. The disc brakes at front and rear axle are arranged in diagnonal brake split. The 4-channel ABS is fitted as standard equipment. The ABS control unit also incorporates the algorithm for the Automatic Stability Control System ASC or ASC+T. The ASC+T shows improved traction compared with the pure stability system ASC and is standard in the BMW 850i with manual gear box. The automatic gear box equipped BMW 850i are supplied with ASC, the ASC+T is available as an option. Both systems, the ASC and the ASC+T are described with special view on the electronical and hydraulical network in the car. A performance comparison of the ASC-systems completes the description. (orig.).

  18. Strategies for building reference standards for autoantibodies

    Directory of Open Access Journals (Sweden)

    Joanna eSheldon

    2015-04-01

    Full Text Available Producing robust, certified, traceable reference material for autoantibody testing is a vital element in maintaining the validity of results that are generated in the daily clinical laboratory routine. This is a huge challenge because of the high number of variables involved in the detection and measurement of the autoantibodies. The production of such materials is time consuming and needs rigorous attention to detail; this is best achieved by an overarching independent body who will oversee the process in a not for profit manner.Much effort has been made to build international standards for quantitative and qualitative assays based on monoclonal antibodies, obtained from affinity purification and plasmapheresis. The big challenge is to respect individual differences in immune response to the same antigen. A promising ongoing initiative is the construction of pools with monospecific samples from different individuals.

  19. Electrothermal frequency references in standard CMOS

    CERN Document Server

    Kashmiri, S Mahdi

    2013-01-01

    This book describes an alternative method of accurate on-chip frequency generation in standard CMOS IC processes. This method exploits the thermal-diffusivity of silicon, the rate at which heat diffuses through a silicon substrate.  This is the first book describing thermal-diffusivity-based frequency references, including the complete theoretical methodology supported by practical realizations that prove the feasibility of the method.  Coverage also includes several circuit and system-level solutions for the analog electronic circuit design challenges faced.   ·         Surveys the state-of-the-art in all-silicon frequency references; ·         Examines the thermal properties of silicon as a solution for the challenge of on-chip accurate frequency generation; ·         Uses simplified modeling approaches that allow an electronics engineer easily to simulate the electrothermal elements; ·         Follows a top-down methodology in circuit design, in which system-level des...

  20. Prevalence of cervical intraepithelial neoplasia grades II/III and cervical cancer in patients with cytological diagnosis of atypical squamous cells when high-grade intraepithelial lesions (ASC-H cannot be ruled out

    Directory of Open Access Journals (Sweden)

    Andréa Cytryn

    Full Text Available CONTEXT AND OBJECTIVE: The latest update of the Bethesda System divided the category of atypical squamous cells of undetermined significance (ASCUS into ASC-US (undetermined significance and ASC-H (high-grade intraepithelial lesion cannot be ruled out. The aims here were to measure the prevalence of pre-invasive lesions (cervical intraepithelial neoplasia, CIN II/III and cervical cancer among patients referred to Instituto Fernandes Figueira (IFF with ASC-H cytology, and compare them with ASC-US cases. DESIGN AND SETTING: Cross-sectional study with retrospective data collection, at the IFF Cervical Pathology outpatient clinic. METHODS: ASCUS cases referred to IFF from November 1997 to September 2007 were reviewed according to the 2001 Bethesda System to reach cytological consensus. The resulting ASC-H and ASC-US cases, along with new cases, were analyzed relative to the outcome of interest. The histological diagnosis (or cytocolposcopic follow-up in cases without such diagnosis was taken as the gold standard. RESULTS: The prevalence of CIN II/III in cases with ASC-H cytology was 19.29% (95% confidence interval, CI, 9.05-29.55% and the risk of these lesions was greater among patients with ASC-H than with ASC-US cytology (prevalence ratio, PR, 10.42; 95% CI, 2.39-45.47; P = 0.0000764. Pre-invasive lesions were more frequently found in patients under 50 years of age with ASC-H cytology (PR, 2.67; 95% CI, 0.38-18.83; P = 0.2786998. There were no uterine cervical cancer cases. CONCLUSION: The prevalence of CIN II/III in patients with ASC-H cytology was significantly higher than with ASC-US, and division into ASC diagnostic subcategories had good capacity for discriminating the presence of pre-invasive lesions.

  1. Prevalence of cervical intraepithelial neoplasia grades II/III and cervical cancer in patients with cytological diagnosis of atypical squamous cells when high-grade intraepithelial lesions (ASC-H) cannot be ruled out.

    Science.gov (United States)

    Cytryn, Andréa; Russomano, Fábio Bastos; Camargo, Maria José de; Zardo, Lucília Maria Gama; Horta, Nilza Maria Sobral Rebelo; Fonseca, Rachel de Carvalho Silveira de Paula; Tristão, Maria Aparecida; Monteiro, Aparecida Cristina Sampaio

    2009-09-01

    The latest update of the Bethesda System divided the category of atypical squamous cells of undetermined significance (ASCUS) into ASC-US (undetermined significance) and ASC-H (high-grade intraepithelial lesion cannot be ruled out). The aims here were to measure the prevalence of pre-invasive lesions (cervical intraepithelial neoplasia, CIN II/III) and cervical cancer among patients referred to Instituto Fernandes Figueira (IFF) with ASC-H cytology, and compare them with ASC-US cases. Cross-sectional study with retrospective data collection, at the IFF Cervical Pathology outpatient clinic. ASCUS cases referred to IFF from November 1997 to September 2007 were reviewed according to the 2001 Bethesda System to reach cytological consensus. The resulting ASC-H and ASC-US cases, along with new cases, were analyzed relative to the outcome of interest. The histological diagnosis (or cytocolposcopic follow-up in cases without such diagnosis) was taken as the gold standard. The prevalence of CIN II/III in cases with ASC-H cytology was 19.29% (95% confidence interval, CI, 9.05-29.55%) and the risk of these lesions was greater among patients with ASC-H than with ASC-US cytology (prevalence ratio, PR, 10.42; 95% CI, 2.39-45.47; P = 0.0000764). Pre-invasive lesions were more frequently found in patients under 50 years of age with ASC-H cytology (PR, 2.67; 95% CI, 0.38-18.83); P = 0.2786998). There were no uterine cervical cancer cases. The prevalence of CIN II/III in patients with ASC-H cytology was significantly higher than with ASC-US, and division into ASC diagnostic subcategories had good capacity for discriminating the presence of pre-invasive lesions.

  2. Generation of gaseous methanol reference standards

    International Nuclear Information System (INIS)

    Geib, R.C.

    1991-01-01

    Methanol has been proposed as an automotive fuel component. Reliable, accurate methanol standards are essential to support widespread monitoring programs. The monitoring programs may include quantification of methanol from tailpipe emissions, evaporative emissions, plus ambient air methanol measurements. This paper will present approaches and results in the author's investigation to develop high accuracy methanol standards. The variables upon which the authors will report results are as follows: (1) stability of methanol gas standards, the studies will focus on preparation requirements and stability results from 10 to 1,000 ppmv; (2) cylinder to instrument delivery system components and purge technique, these studies have dealt with materials in contact with the sample stream plus static versus flow injection; (3) optimization of gas chromatographic analytical system will be discussed; (4) gas chromatography and process analyzer results and utility for methanol analysis will be presented; (5) the accuracy of the methanol standards will be qualified using data from multiple studies including: (a) gravimetric preparation; (b) linearity studies; (c) independent standards sources such as low pressure containers and diffusion tubes. The accuracy will be provided as a propagation of error from multiple sources. The methanol target concentrations will be 10 to 500 ppmv

  3. Standards for reference reactor physics measurements

    International Nuclear Information System (INIS)

    Harris, D.R.; Cokinos, D.M.; Uotinen, V.

    1990-01-01

    Reactor physics analysis methods require experimental testing and confirmation over the range of practical reactor configurations and states. This range is somewhat limited by practical fuel types such as actinide oxides or carbides enclosed in metal cladding. On the other hand, this range continues to broaden because of the trend of using higher enrichment, if only slightly enriched, electric utility fuel. The need for experimental testing of the reactor physics analysis methods arises in part because of the continual broadening of the range of core designs, and in part because of the nature of the analysis methods. Reactor physics analyses are directed primarily at the determination of core reactivities and reaction rates, the former largely for reasons of reactor control, and the latter largely to ensure that material limitations are not violated. Errors in these analyses can be regarded as being from numerics, from the data base, and from human factors. For numerical, data base, and human factor reasons, then, it is prudent and customary to qualify reactor physical analysis methods against experiments. These experiments can be treated as being at low power or at high power, and each of these types is subject to an American National Standards Institute standard. The purpose of these standards is to aid in improving and maintaining adequate quality in reactor physics methods, and it is from this point of view that the standards are examined here

  4. 15 CFR 200.105 - Standard reference data.

    Science.gov (United States)

    2010-01-01

    ... for application in energy, environment and health, industrial process design, materials durability... application in research, development, engineering design, and commerce. The Office of Standard Reference Data...

  5. Structure of AscE and Induced Burial Regions in AscE and AscG upon Formation of the Chaperone Needle-subunit Complex of Type III Secretion System in Aeromonas Hydrophila

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Y.; Yu, H; Leung, K; Sivaraman, J; Mok, Y

    2008-01-01

    In the type III secretion system (T3SS) of Aeromonas hydrophila, the putative needle complex subunit AscF requires both putative chaperones AscE and AscG for formation of a ternary complex to avoid premature assembly. Here we report the crystal structure of AscE at 2.7 A resolution and the mapping of buried regions of AscE, AscG, and AscF in the AscEG and AscEFG complexes using limited protease digestion. The dimeric AscE is comprised of two helix-turn-helix monomers packed in an antiparallel fashion. The N-terminal 13 residues of AscE are buried only upon binding with AscG, but this region is found to be nonessential for the interaction. AscE functions as a monomer and can be coexpressed with AscG or with both AscG and AscF to form soluble complexes. The AscE binding region of AscG in the AscEG complex is identified to be within the N-terminal 61 residues of AscG. The exposed C-terminal substrate-binding region of AscG in the AscEG complex is induced to be buried only upon binding to AscF. However, the N-terminal 52 residues of AscF remain exposed even in the ternary AscEFG complex. On the other hand, the 35-residue C-terminal region of AscF in the complex is resistant to protease digestion in the AscEFG complex. Site-directed mutagenesis showed that two C-terminal hydrophobic residues, Ile83 and Leu84, of AscF are essential for chaperone binding.

  6. ENAA of iodine in standard reference material lyophilized human urine

    International Nuclear Information System (INIS)

    Zhang Yongbao; Wang Ke; Wang Ganfeng

    1997-01-01

    The contents of iodine in two kinds of standard reference materials lyophilized human urine are determined by ENAA. The sensitivity of this method is ten times higher than that of TNAA, and the relative standard deviations of ten measurements are 2.9% and 3.3%, respectively. Two certificated reference samples are used for verification of the analysis. The analytical results are in agreement with the recommended values, and the relative error is less than 3%

  7. Thermal-Diffusivity-Based Frequency References in Standard CMOS

    NARCIS (Netherlands)

    Kashmiri, S.M.

    2012-01-01

    In recent years, a lot of research has been devoted to the realization of accurate integrated frequency references. A thermal-diffusivity-based (TD) frequency reference provides an alternative method of on-chip frequency generation in standard CMOS technology. A frequency-locked loop locks the

  8. Fabricating defensible reference standards for the NDA lab

    Energy Technology Data Exchange (ETDEWEB)

    Ceo, R.N.; May, P.K. [Oak Ridge Y-12 Plant, TN (United States)

    1997-11-01

    Nondestructive analysis (NDA) is performed at the Oak Ridge Y-12 Plant in support of the enriched uranium operations. Process materials are analyzed using gamma ray- and neutron-based instruments including segmented gamma scanners, solution assay systems, and an active well coincidence counter. Process wastes are also discarded based on results of these measurements. Good analytical practice, as well as applicable regulations, mandates that these analytical methods be calibrated using reference materials traceable to the national standards base. Reference standards for NDA instruments are not commercially available owing to the large quantities of special nuclear materials involved. Instead, representative materials are selected from each process stream, then thoroughly characterized by methods that are traceable to the national standards base. This paper discusses the process materials to be analyzed, reference materials selected for calibrating each NDA instrument, and details of their characterization and fabrication into working calibrations standards. Example calibration curves are also presented. 4 figs.

  9. Fabricating defensible reference standards for the NDA lab

    International Nuclear Information System (INIS)

    Ceo, R.N.; May, P.K.

    1997-01-01

    Nondestructive analysis (NDA) is performed at the Oak Ridge Y-12 Plant in support of the enriched uranium operations. Process materials are analyzed using gamma ray- and neutron-based instruments including segmented gamma scanners, solution assay systems, and an active well coincidence counter. Process wastes are also discarded based on results of these measurements. Good analytical practice, as well as applicable regulations, mandates that these analytical methods be calibrated using reference materials traceable to the national standards base. Reference standards for NDA instruments are not commercially available owing to the large quantities of special nuclear materials involved. Instead, representative materials are selected from each process stream, then thoroughly characterized by methods that are traceable to the national standards base. This paper discusses the process materials to be analyzed, reference materials selected for calibrating each NDA instrument, and details of their characterization and fabrication into working calibrations standards. Example calibration curves are also presented. 4 figs

  10. Bibliographic Citations With Special Reference Indian Bibliographic Standard

    Directory of Open Access Journals (Sweden)

    Reshmi Sarkar

    2015-08-01

    Full Text Available Bibliographic citation is playing an important role today to ensure the completeness of all research activities. They occupy an integral part as a reference in all types of resources need. The author while writing a paper takes the references from a number of documents and finally quotes them with its bibliographic details to recognize the work of earlier authors in the same field of study. With the virtually exponential growth in the research literatures throughout the 20th century it has become clear that the larger the literature the more difficult are the problems caused by poorly crafted bibliographic references. Scholarly societies like publishers of research journals have either produced their own or have endorsed common bibliographic style manuals or standards. In this study we have studied several style manuals and standards for bibliographic referencing and several editorial guidelines for this purpose to compare them. Indian bibliographic standard gets special attention.

  11. On criteria for examining analysis quality with standard reference material

    International Nuclear Information System (INIS)

    Yang Huating

    1997-01-01

    The advantages and disadvantages and applicability of some criteria for examining analysis quality with standard reference material are discussed. The combination of the uncertainties of the instrument examined and the reference material should be determined on the basis of specific situations. Without the data of the instrument's uncertainty, it would be applicable to substitute the standard deviation multiplied by certain times for the uncertainty. The result of the examining should not result in more error reported in routine measurements than it really is. Over strict examining should also be avoided

  12. Advanced Stirling Convertor (ASC) Technology Maturation

    Science.gov (United States)

    Wong, Wayne A.; Wilson, Scott; Collins, Josh; Wilson, Kyle

    2016-01-01

    The Advanced Stirling Convertor (ASC) development effort was initiated by NASA Glenn Research Center with contractor Sunpower, Inc., to develop high-efficiency thermal-to-electric power conversion technology for NASA Radioisotope Power Systems (RPSs). Early successful performance demonstrations led to the expansion of the project as well as adoption of the technology by the Department of Energy (DOE) and system integration contractor Lockheed Martin Space Systems Company as part of the Advanced Stirling Radioisotope Generator (ASRG) flight project. The ASRG integrates a pair of ASCs to convert the heat from a pair of General Purpose Heat Source (GPHS) modules into electrical power. The expanded NASA ASC effort included development of several generations of ASC prototypes or engineering units to help prepare the ASC technology and Sunpower for flight implementation. Sunpower later had two parallel contracts allowing the last of the NASA engineering units called ASC-E3 to serve as pathfinders for the ASC-F flight convertors being built for DOE. The ASC-E3 convertors utilized the ASC-F flight specifications and were built using the ASC-F design and process documentation. Shortly after the first ASC-F pair achieved initial operation, due to budget constraints, the DOE ASRG flight development contract was terminated. NASA continues to invest in the development of Stirling RPS technology including continued production of the ASC-E3 convertors, seven of which have been delivered with one additional unit in production. Starting in fiscal year 2015, Stirling Convertor Technology Maturation has been reorganized as an element of the RPS Stirling Cycle Technology Development (SCTD) Project and long-term plans for continued Stirling technology advancement are in reformulation. This paper provides a status on the ASC project, an overview of advancements made in the design and production of the ASC at Sunpower, and a summary of acceptance tests, reliability tests, and tactical

  13. Newly developed standard reference materials for organic contaminant analysis

    Energy Technology Data Exchange (ETDEWEB)

    Poster, D.; Kucklick, J.; Schantz, M.; Porter, B.; Wise, S. [National Inst. of Stand. and Technol., Gaithersburg, MD (USA). Center for Anal. Chem.

    2004-09-15

    The National Institute of Standards and Technology (NIST) has issued a number of Standard Reference Materials (SRM) for specified analytes. The SRMs are biota and biological related materials, sediments and particle related SRMs. The certified compounds for analysis are polychlorinated biphenyls (PCB), polycylic aromatic hydrocarbons (PAH) and their nitro-analogues, chlorinated pesticides, methylmercury, organic tin compounds, fatty acids, polybrominated biphenyl ethers (PBDE). The authors report on origin of materials and analytic methods. (uke)

  14. Standard digital reference images for inspection of aluminum castings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These digital reference images illustrate the types and degrees of discontinuities that may be found in aluminum-alloy castings. The castings illustrated are in thicknesses of 1/ 4 in. [6.35 mm] and 3/4 in. [19.1mm]. 1.2 All areas of this standard may be open to agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization. These items should be addressed in the purchase order or the contract. 1.3 The values stated in inch-pound units are to be regarded as standard. 1.4 These digital reference images are not intended to illustrate the types and degrees of discontinuities found in aluminum-alloy castings when performing film radiography. If performing film radiography of aluminum-alloy castings, refer to Reference Radiographs E 155. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and he...

  15. Halogens determination in vegetable NBS standard reference materials

    International Nuclear Information System (INIS)

    Stella, R.; Genova, N.; Di Casa, M.

    1977-01-01

    Levels of all four halogens in Orchard Leaves, Pine Needles and Tomato Leaves NBS reference standards were determined. For fluorine a spiking isotope dilution method was used followed by HF absorption on glass beads. Instrumental nuclear activation analysis was adopted for chlorine and bromine determination. Radiochemical separation by a distillation procedure was necessary for iodine nuclear activation analysis after irradiation. Activation parameters of Cl, Br and I are reported. Results of five determinations for each halogen in Orchard Leaves, Pine Needles and Tomato Leaves NBS Standard Materials and Standard deviations of the mean are reported. (T.I.)

  16. Ambulatory Surgical Center (ASC) Payment System

    Data.gov (United States)

    U.S. Department of Health & Human Services — This file contains a summary of service utilization by ASC supplier and is derived from 2011 ASC line item level data, updated through June 2012, that is, line items...

  17. Determination of polybrominated diphenyl ethers in environmental standard reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, Heather M.; Schantz, Michele M.; Wise, Stephen A. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); Keller, Jennifer M.; Kucklick, John R. [National Institute of Standards and Technology, Analytical Chemistry Division, Hollings Marine Laboratory, Charleston, SC (United States); Leigh, Stefan D. [National Institute of Standards and Technology, Statistical Engineering Division, Gaithersburg, MD (United States)

    2007-04-15

    Standard reference materials (SRMs) are valuable tools in developing and validating analytical methods to improve quality assurance standards. The National Institute of Standards and Technology (NIST) has a long history of providing environmental SRMs with certified concentrations of organic and inorganic contaminants. Here we report on new certified and reference concentrations for 27 polybrominated diphenyl ether (PBDE) congeners in seven different SRMs: cod-liver oil, whale blubber, fish tissue (two materials), mussel tissue and sediment (two materials). PBDEs were measured in these SRMs, with the lowest concentrations measured in mussel tissue (SRM 1974b) and the highest in sediment collected from the New York/New Jersey Waterway (SRM 1944). Comparing the relative PBDE congener concentrations within the samples, we found the biota SRMs contained primarily tetrabrominated and pentabrominated diphenyl ethers, whereas the sediment SRMs contained primarily decabromodiphenyl ether (BDE 209). The cod-liver oil (SRM 1588b) and whale blubber (SRM 1945) materials were also found to contain measurable concentrations of two methoxylated PBDEs (MeO-BDEs). Certified and reference concentrations are reported for 12 PBDE congeners measured in the biota SRMs and reference values are available for two MeO-BDEs. Results from a sediment interlaboratory comparison PBDE exercise are available for the two sediment SRMs (1941b and 1944). (orig.)

  18. Advanced Stirling Convertor (ASC-E2) Characterization Testing

    Science.gov (United States)

    Williams, Zachary D.; Oriti, Salvatore M.

    2012-01-01

    Testing has been conducted on Advanced Stirling Convertors (ASCs)-E2 at NASA Glenn Research Center in support of the Advanced Stirling Radioisotope Generator (ASRG) project. This testing has been conducted to understand sensitivities of convertor parameters due to environmental and operational changes during operation of the ASRG in missions to space. This paper summarizes test results and explains the operation of the ASRG during space missions

  19. A routine chromium determination in biological materials; application to various reference materials and standard reference materials

    International Nuclear Information System (INIS)

    Tjioe, P.S.; Goeij, J.J.M. de; Volkers, K.J.

    1979-01-01

    The determination limit under standard working conditions of chromium in biological materials is discussed. Neutron activation analysis and atomic spectrometry have been described for some analytical experiences with NBS SRM 1577 reference material. The chromium determination is a part of a larger multi-element scheme for the determination of 12 elements in biological materials

  20. Consensus values for NIST biological and environmental Standard Reference Materials

    International Nuclear Information System (INIS)

    Roelandts, I.; Gladney, E.S.

    1998-01-01

    The National Institute of Standards and Technology (NIST, formerly the National Bureau of Standards or NBS) has produced numerous Standard Reference Materials (SRM) for use in biological and environmental analytical chemistry. The value listed on the ''NIST Certificate of Analysis'' is the present best estimate of the ''true'' concentration of that element and is not expected to deviate from that concentration by more than the stated uncertainty. However, NIST does not certify the elemental concentration of every constituent and the number of elements reported in the NIST programs tends to be limited.Numerous analysts have published concentration data on these reference materials. Major journals in analytical chemistry, books, proceedings and ''technical reports'' have been surveyed to collect these available literature values. A standard statistical approach has been employed to evaluate the compiled data. Our methodology has been developed in a series of previous papers. Some subjective criteria are first used to reject aberrant data. Following these eliminations, an initial arithmetic mean and standard deviation (S.D.) are computed from remaining data for each element. All data now outside two S.D. from the initial mean are dropped and a second mean and S.D. recalculated. These final means and associated S.D. are reported as ''consensus values'' in our tables. (orig.)

  1. 77 FR 25168 - Appraisal Subcommittee (ASC); ASC Rules of Operation; Amended

    Science.gov (United States)

    2012-04-27

    ... heads of the Bureau of Consumer Financial Protection and the Federal Housing Finance Agency. The ASC Rules of Operation serve as corporate bylaws outlining the ASC's purpose, functions, authority... Title XI. The ASC Rules of Operation serve as corporate bylaws outlining the ASC's purpose, functions...

  2. Characterization of the NIST shellfish Standard Reference Material 4358

    International Nuclear Information System (INIS)

    Nour, S.; Inn, K.G.W.; Filliben, J.; Gaast van der, H.; Men, L.C.; Calmet, D.; Altzitzoglou, T.; Povinec, P.; Takata, Y.; Wisdom, M.

    2013-01-01

    A new shellfish Standard Reference Material 4358 was developed by the National Institute of Standards and Technology through an international interlaboratory comparison that involved twelve laboratories-participants from nine countries. The results from the participants were statistically evaluated, and the most robust certified values were based on the median of laboratories’ reported means and the uncertainties derived using the bootstrap method. Massic activity certified values were established for fourteen radionuclides, five activity ratios, and informational massic activity values for eight more radionuclides and two activity ratios. (author)

  3. Positive animal welfare states and reference standards for welfare assessment.

    Science.gov (United States)

    Mellor, D J

    2015-01-01

    Developments in affective neuroscience and behavioural science during the last 10-15 years have together made it increasingly apparent that sentient animals are potentially much more sensitive to their environmental and social circumstances than was previously thought to be the case. It therefore seems likely that both the range and magnitude of welfare trade-offs that occur when animals are managed for human purposes have been underestimated even when minimalistic but arguably well-intentioned attempts have been made to maintain high levels of welfare. In light of these neuroscience-supported behaviour-based insights, the present review considers the extent to which the use of currently available reference standards might draw attention to these previously neglected areas of concern. It is concluded that the natural living orientation cannot provide an all-embracing or definitive welfare benchmark because of its primary focus on behavioural freedom. However assessments of this type, supported by neuroscience insights into behavioural motivation, may now carry greater weight when used to identify management practices that should be avoided, discontinued or substantially modified. Using currently accepted baseline standards as welfare reference points may result in small changes being accorded greater significance than would be the case if they were compared with higher standards, and this could slow the progress towards better levels of welfare. On the other hand, using "what animals want" as a reference standard has the appeal of focusing on the specific resources or conditions the animals would choose themselves and can potentially improve their welfare more quickly than the approach of making small increments above baseline standards. It is concluded that the cautious use of these approaches in different combinations could lead to recommendations that would more effectively promote positive welfare states in hitherto neglected areas of concern.

  4. 78 FR 13243 - Updates to Standards Incorporated by Reference; Reapproved ASTM Standards; Technical Amendment

    Science.gov (United States)

    2013-02-27

    ... Characteristics of Plastic Film 2009)[egr]1. and Sheeting. Standard Specification for F682-82a F682-82a 46 56.01-2... (Reapproved Standard Test Method for Determining Gas 2009)[egr]1. Permeability Characteristics of Plastic Film... Permeability Characteristics of Plastic Film and Sheeting (approved May 1, 2009), incorporation by reference...

  5. Determination of trace elements in standard reference materials by the ko-standardization method

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Stegnar, P.; Jovanovic, S.

    1990-01-01

    The k o -standardization method is suitable for routine multielement determinations by reactor neutron activation analysis (NAA). Investigation of NIST standard reference materials SRM 1571 Orchard Leaves, SRM 1572 Citrus leaves, and SRM 1573 Tomato Leaves showed the systematic error of 12 certified elements determined to be less than 8%. Thirty-four elements were determined in NIST proposed SRM 1515 Apple Leaves

  6. A reference standard-based quality assurance program for radiology.

    Science.gov (United States)

    Liu, Patrick T; Johnson, C Daniel; Miranda, Rafael; Patel, Maitray D; Phillips, Carrie J

    2010-01-01

    The authors have developed a comprehensive radiology quality assurance (QA) program that evaluates radiology interpretations and procedures by comparing them with reference standards. Performance metrics are calculated and then compared with benchmarks or goals on the basis of published multicenter data and meta-analyses. Additional workload for physicians is kept to a minimum by having trained allied health staff members perform the comparisons of radiology reports with the reference standards. The performance metrics tracked by the QA program include the accuracy of CT colonography for detecting polyps, the false-negative rate for mammographic detection of breast cancer, the accuracy of CT angiography detection of coronary artery stenosis, the accuracy of meniscal tear detection on MRI, the accuracy of carotid artery stenosis detection on MR angiography, the accuracy of parathyroid adenoma detection by parathyroid scintigraphy, the success rate for obtaining cortical tissue on ultrasound-guided core biopsies of pelvic renal transplants, and the technical success rate for peripheral arterial angioplasty procedures. In contrast with peer-review programs, this reference standard-based QA program minimizes the possibilities of reviewer bias and erroneous second reviewer interpretations. The more objective assessment of performance afforded by the QA program will provide data that can easily be used for education and management conferences, research projects, and multicenter evaluations. Additionally, such performance data could be used by radiology departments to demonstrate their value over nonradiology competitors to referring clinicians, hospitals, patients, and third-party payers. Copyright 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Quality of Standard Reference Materials for Short Time Activation Analysis

    International Nuclear Information System (INIS)

    Ismail, S.S.; Oberleitner, W.

    2003-01-01

    Some environmental reference materials (CFA-1633 b, IAEA-SL-1, SARM-1,BCR-176, Coal-1635, IAEA-SL-3, BCR-146, and SRAM-5) were analysed by short-time activation analysis. The results show that these materials can be classified in three groups, according to their activities after irradiation. The obtained results were compared in order to create a quality index for determination of short-lived nuclides at high count rates. It was found that Cfta is not a suitable standard for determining very short-lived nuclides (half-lives<1 min) because the activity it produces is 15-fold higher than that SL-3. Biological reference materials, such as SRM-1571, SRM-1573, SRM-1575, SRM-1577, IAEA-392, and IAEA-393, were also investigated by a higher counting efficiency system. The quality of this system and its well-type detector for investigating short-lived nuclides was discussed

  8. Physical fitness reference standards in European children: the IDEFICS study.

    Science.gov (United States)

    De Miguel-Etayo, P; Gracia-Marco, L; Ortega, F B; Intemann, T; Foraita, R; Lissner, L; Oja, L; Barba, G; Michels, N; Tornaritis, M; Molnár, D; Pitsiladis, Y; Ahrens, W; Moreno, L A

    2014-09-01

    A low fitness status during childhood and adolescence is associated with important health-related outcomes, such as increased future risk for obesity and cardiovascular diseases, impaired skeletal health, reduced quality of life and poor mental health. Fitness reference values for adolescents from different countries have been published, but there is a scarcity of reference values for pre-pubertal children in Europe, using harmonised measures of fitness in the literature. The IDEFICS study offers a good opportunity to establish normative values of a large set of fitness components from eight European countries using common and well-standardised methods in a large sample of children. Therefore, the aim of this study is to report sex- and age-specific fitness reference standards in European children. Children (10,302) aged 6-10.9 years (50.7% girls) were examined. The test battery included: the flamingo balance test, back-saver sit-and-reach test (flexibility), handgrip strength test, standing long jump test (lower-limb explosive strength) and 40-m sprint test (speed). Moreover, cardiorespiratory fitness was assessed by a 20-m shuttle run test. Percentile curves for the 1st, 3rd, 10th, 25th, 50th, 75th, 90th, 97th and 99th percentiles were calculated using the General Additive Model for Location Scale and Shape (GAMLSS). Our results show that boys performed better than girls in speed, lower- and upper-limb strength and cardiorespiratory fitness, and girls performed better in balance and flexibility. Older children performed better than younger children, except for cardiorespiratory fitness in boys and flexibility in girls. Our results provide for the first time sex- and age-specific physical fitness reference standards in European children aged 6-10.9 years.

  9. Neutron activation analysis for certification of standard reference materials

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Zayas, G.; Hernandez Rivero, A.; Ribeiro Guevara, S.

    1996-01-01

    Neutron activation analysis is used extensively as one of the analytical techniques in the certification of standard reference materials. Characteristics of neutron activation analysis which make it valuable in this role are: accuracy multielemental capability to asses homogeneity, high sensitivity for many elements, and essentially non-destructive method. This paper report the concentrations of 30 elements (major, minor and trace elements) in four Cuban samples. The samples were irradiated in a thermal neutron flux of 10 12- 10 13 n.cm 2. s -1. The gamma ray spectra were measured by HPGe detectors and were analyzed using ACTAN program development in Center of Applied Studies for Nuclear Development

  10. Certification of standard reference materials employing neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Hernandez Rivero, A.; Molina Insfran, J.; Ribeiro Guevara, S.; Santana Encinosa, C.; Perez Zayas, G.

    1997-01-01

    Neutron activation analysis (Naa) is used extensively as one of the analytical techniques in the certification of standard reference materials (Srm). Characteristics of Naa which make it valuable in this role are: accuracy; multielemental capability; ability to assess homogeneity; high sensitivity for many elements, and essentially non-destructive method. This paper reports the concentrations of thirty elements (major, minor and trace elements) in four Cuban Srm's. The samples were irradiated in a thermal neutron flux of 10 12 -10 13 neutrons.cm -2 .s -1 . The gamma-ray spectra were measured by HPGe detectors and were analysed using ACTAN program, developed in CEADEN. (author) [es

  11. Japanese tea leaves: a possible biological standard reference material

    International Nuclear Information System (INIS)

    Fuwa, Keiichiro; Notsu, Kenji; Tsunoda, Kin-ichi; Kato, Hideaki; Yamamoto, Yuko.

    1978-01-01

    Japanese Tea Leaves, prepared by pulverizing with an agate ball mill and sieving with a Saran fiber sieve (50 mesh) were assessed as a possible biological standard reference material for elemental analysis. The metal content of the tea leaves was determined independently at two laboratories using atomic absorption and flame emission spectrometry. Neutron activation analysis was also performed to determine the content (21 elements) of Tea Leaves. For some elements the result from the various methods were compared. The characteristics of Tea Leaves are discussed and the elemental composition is compared to that of Orchard Leaves (NBS SRM, 1571). The most significant characteristic of Tea Leaves was the high manganese content. (auth.)

  12. Standard reference materials analysis for MINT Radiocarbon Laboratory

    International Nuclear Information System (INIS)

    Noraishah Othman; Kamisah Alias; Nasasni Nasrul

    2004-01-01

    As a follow-up to the setting up of the MINT Radiocarbon Dating facility. an exercise on the IAEA standard reference materials was carried out. Radiocarbon laboratories frequently used these 8 natural samples to verify their systems. The materials were either pretreated or analysed directly to determine the activity of 14 C isotopes of the five samples expressed in % Modern (pMC) terms and to make recommendations on further use of these materials. We present the results of the five materials and discuss the analyses that were undertaken. (Author)

  13. The Quality Control of Reference Standards in Metrology Dosimetry

    International Nuclear Information System (INIS)

    Lazarevic, Dj.; Ciraj Bjelac, O.; Kovacevic, M.; Vukcevic, M.

    2008-01-01

    This works presents the quality control tests applied to two types of ionization chambers with suitable electrometers. Measuring assemblies were tested in order to assess their performance and adequacy for use as reference standards in ionising radiation metrology laboratory for calibrations in the field of radiotherapy and radiation protection. Two types of ionizing chambers (Farmer type, 0.6 cm 3 and spherical ionizing chamber, 1 l) with suitable electrometers were tested. Following test were performed: repeatability, long term stability, polarity and leakage current measurement. All tested measuring assemblies demonstrated proper performance, correctness and high reliance of measurements, since all implemented quality control test results were within acceptable limits. (author)

  14. Development of the NBS beryllium isotopic standard reference material

    International Nuclear Information System (INIS)

    Inn, K.G.W; Fassett, J.D.; Coursey, B.M.; Walker, R.L.; Raman, S.

    1987-01-01

    The National Bureau of Standards, in conjunction with the Oak Ridge National Laboratory and the Accelerator Mass Spectrometry community, is in the process of developing a beryllium isotopic solution Standard Reference Material. The master 10 Be/ 9 Be solution was characterized isotopically by resonance-ionization and secondary-ion mass-spectrometric-based techniques, and radioactivity measurements were by liquid scintillation counting. The master solution was gravimetrically diluted with 9 Be to a final 10 Be/ 9 Be atomic ratio of 3 x 10 -11 . The preliminary data indicate a half life for 10 Be of 1.3 million years, and AMS measurements are within 10% of the known beryllium isotopic ratio

  15. New Carbonate Standard Reference Materials for Boron Isotope Geochemistry

    Science.gov (United States)

    Stewart, J.; Christopher, S. J.; Day, R. D.

    2015-12-01

    The isotopic composition of boron (δ11B) in marine carbonates is well established as a proxy for past ocean pH. Yet, before palaeoceanographic interpretation can be made, rigorous assessment of analytical uncertainty of δ11B data is required; particularly in light of recent interlaboratory comparison studies that reported significant measurement disagreement between laboratories [1]. Well characterised boron standard reference materials (SRMs) in a carbonate matrix are needed to assess the accuracy and precision of carbonate δ11B measurements throughout the entire procedural chemistry; from sample cleaning, to ionic separation of boron from the carbonate matrix, and final δ11B measurement by multi-collector inductively coupled plasma mass spectrometry. To date only two carbonate reference materials exist that have been value-assigned by the boron isotope measurement community [2]; JCp-1 (porites coral) and JCt-1 (Giant Clam) [3]. The National Institute of Standards and Technology (NIST) will supplement these existing standards with new solution based inorganic carbonate boron SRMs that replicate typical foraminiferal and coral B/Ca ratios and δ11B values. These new SRMs will not only ensure quality control of full procedural chemistry between laboratories, but have the added benefits of being both in abundant supply and free from any restrictions associated with shipment of biogenic samples derived from protected species. Here we present in-house δ11B measurements of these new boron carbonate SRM solutions. These preliminary data will feed into an interlaboratory comparison study to establish certified values for these new NIST SRMs. 1. Foster, G.L., et al., Chemical Geology, 2013. 358(0): p. 1-14. 2. Gutjahr, M., et al., Boron Isotope Intercomparison Project (BIIP): Development of a new carbonate standard for stable isotopic analyses. Geophysical Research Abstracts, EGU General Assembly 2014, 2014. 16(EGU2014-5028-1). 3. Inoue, M., et al., Geostandards and

  16. Determination of sampling constants in NBS geochemical standard reference materials

    International Nuclear Information System (INIS)

    Filby, R.H.; Bragg, A.E.; Grimm, C.A.

    1986-01-01

    Recently Filby et al. showed that, for several elements, National Bureau of Standards (NBS) Fly Ash standard reference material (SRM) 1633a was a suitable reference material for microanalysis (sample weights 2 , and the mean sample weight, W vector, K/sub s/ = (S/sub s/%) 2 W vector, could not be determined from these data because it was not possible to quantitate other sources of error in the experimental variances. K/sub s/ values for certified elements in geochemical SRMs provide important homogeneity information for microanalysis. For mineralogically homogeneous SRMs (i.e., small K/sub s/ values for associated elements) such as the proposed clays, it is necessary to determine K/sub s/ by analysis of very small sample aliquots to maximize the subsampling variance relative to other sources of error. This source of error and the blank correction for the sample container can be eliminated by determining K/sub s/ from radionuclide activities of weighed subsamples of a preirradiated SRM

  17. Pathfinding the Flight Advanced Stirling Convertor Design with the ASC-E3

    Science.gov (United States)

    Wong, Wayne A.; Wilson, Kyle; Smith, Eddie; Collins, Josh

    2012-01-01

    The Advanced Stirling Convertor (ASC) was initially developed by Sunpower, Inc. under contract to NASA Glenn Research Center (GRC) as a technology development project. The ASC technology fulfills NASA's need for high efficiency power convertors for future Radioisotope Power Systems (RPS). Early successful technology demonstrations between 2003 to 2005 eventually led to the expansion of the project including the decision in 2006 to use the ASC technology on the Advanced Stirling Radioisotope Generator (ASRG). Sunpower has delivered 22 ASC convertors of progressively mature designs to date to GRC. Currently, Sunpower with support from GRC, Lockheed Martin Space System Company (LMSSC), and the Department of Energy (DOE) is developing the flight ASC-F in parallel with the ASC-E3 pathfinders. Sunpower will deliver four pairs of ASC-E3 convertors to GRC which will be used for extended operation reliability assessment, independent validation and verification testing, system interaction tests, and to support LMSSC controller verification. The ASC-E3 and -F convertors are being built to the same design and processing documentation and the same product specification. The initial two pairs of ASC-E3 are built before the flight units and will validate design and processing changes prior to implementation on the ASC-F flight convertors. This paper provides a summary on development of the ASC technology and the status of the ASC-E3 build and how they serve the vital pathfinder role ahead of the flight build for ASRG. The ASRG is part of two of the three candidate missions being considered for selection for the Discovery 12 mission.

  18. Nuclear microprobe analysis of the standard reference materials

    International Nuclear Information System (INIS)

    Jaksic, M.; Fazinic, S.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    Most of the presently existing Standard Reference Materials (SRM) for nuclear analytical methods are certified for the analyzed mass of the order of few hundred mg. Typical mass of sample which is analyzed by PIXE or XRF methods is very often below 1 mg. By the development of focused proton or x-ray beams, masses which can be typically analyzed go down to μg or even ng level. It is difficult to make biological or environmental SRMs which can give desired homogeneity at such low scale. However, use of fundamental parameter quantitative evaluation procedures (absolute method), minimize needs for SRMs. In PIXE and micro PIXE setup at our Institute, fundamental parameter approach is used. For exact calibration of the quantitative analysis procedure just one standard sample is needed. In our case glass standards which showed homogeneity down to micron scale were used. Of course, it is desirable to use SRMs for quality assurance, and therefore need for homogenous materials can be justified even for micro PIXE method. In this presentation, brief overview of PIXE setup calibration is given, along with some recent results of tests of several SRMs

  19. International Longitudinal Paediatric Reference Standards for Bone Mineral Content

    Science.gov (United States)

    Baxter-Jones, Adam DG; McKay, Heather; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don

    2014-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women’s Health Study (n=112) and Stanford’s Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement in predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (P accrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. Similar findings were found for PF and FN. Female models for all sites were similar with age, height and weight all independent significant predictors of BMC accrual (P accounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in paediatrics we recommend standards that are sex, age, size and ethnic specific. PMID:19854308

  20. International longitudinal pediatric reference standards for bone mineral content.

    Science.gov (United States)

    Baxter-Jones, Adam D G; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don; McKay, Heather

    2010-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site-specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women's Health Study (n=112) and Stanford's Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement between predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (Paccrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. We report similar findings for the PF and FN. Models for females for all sites were similar with age, height and weight as independent significant predictors of BMC accrual (Paccounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in pediatrics we recommend standards that are sex, age, size and ethnic specific. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  1. Universal Reference RNA as a standard for microarray experiments

    Directory of Open Access Journals (Sweden)

    Fero Michael

    2004-03-01

    Full Text Available Abstract Background Obtaining reliable and reproducible two-color microarray gene expression data is critically important for understanding the biological significance of perturbations made on a cellular system. Microarray design, RNA preparation and labeling, hybridization conditions and data acquisition and analysis are variables difficult to simultaneously control. A useful tool for monitoring and controlling intra- and inter-experimental variation is Universal Reference RNA (URR, developed with the goal of providing hybridization signal at each microarray probe location (spot. Measuring signal at each spot as the ratio of experimental RNA to reference RNA targets, rather than relying on absolute signal intensity, decreases variability by normalizing signal output in any two-color hybridization experiment. Results Human, mouse and rat URR (UHRR, UMRR and URRR, respectively were prepared from pools of RNA derived from individual cell lines representing different tissues. A variety of microarrays were used to determine percentage of spots hybridizing with URR and producing signal above a user defined threshold (microarray coverage. Microarray coverage was consistently greater than 80% for all arrays tested. We confirmed that individual cell lines contribute their own unique set of genes to URR, arguing for a pool of RNA from several cell lines as a better configuration for URR as opposed to a single cell line source for URR. Microarray coverage comparing two separately prepared batches each of UHRR, UMRR and URRR were highly correlated (Pearson's correlation coefficients of 0.97. Conclusion Results of this study demonstrate that large quantities of pooled RNA from individual cell lines are reproducibly prepared and possess diverse gene representation. This type of reference provides a standard for reducing variation in microarray experiments and allows more reliable comparison of gene expression data within and between experiments and

  2. 75 FR 80813 - Appraisal Subcommittee (ASC); ASC Rules of Operation; Amended

    Science.gov (United States)

    2010-12-23

    ... name and must rely on the General Services Administration (GSA) for the procurement of office space by... administration, procurement, and other services, consistent with directives of the ASC. In executing this... Conduct Section 11.01. Ethics Provision. The ASC members of the ASC and its officers and employees shall...

  3. Reference standard for serum bile acids in pregnancy.

    LENUS (Irish Health Repository)

    2012-01-31

    Please cite this paper as: Egan N, Bartels A, Khashan A, Broadhurst D, Joyce C, O\\'Mullane J, O\\'Donoghue K. Reference standard for serum bile acids in pregnancy. BJOG 2012;00:000-000. DOI: 10.1111\\/j.1471-0528.2011.03245.x. Objective Obstetric cholestasis (OC) is a liver disorder characterised by pruritus and elevated serum bile acids (SBA) that affects one in 200 pregnant women. It is associated with adverse perinatal outcomes such as premature delivery and stillbirth. Mild OC is defined as SBA levels of 10-39 mumol\\/l, and severe OC is defined by levels >40 mumol\\/l. SBA levels in normal pregnancy have not been investigated. We aimed to establish reference values for SBA in healthy pregnant women across different trimesters of pregnancy. Design Cross-sectional analysis of SBA levels. Setting A large tertiary referral university teaching maternity hospital. Population Healthy pregnant women with a singleton pregnancy and a body mass index (BMI) < 40, excluding women with significant alcohol intake, history of liver disease, prior cholecystectomy and OC. Methods Cross-sectional analysis of SBA levels at 12, 20, 28 and 36 weeks of gestation, and on days 1-3 postpartum. Main outcome measures SBA levels in mumol\\/l. Results A total of 219 women attending for antenatal care were recruited, and SBA levels were assayed at 12, 20, 28 and 36 weeks of gestation, and up to 72 hours postpartum (n = 44-49 cases at each stage). The majority were white European women, with a median age of 30 years (range 17-46 years) and median BMI of 25 (range 18-38). Values of SBA ranged from 0.3 to 9.8 mumol\\/l in 216 women, with only three measurements outside this range. There were no significant changes throughout pregnancy. Conclusions SBA values in uncomplicated pregnancies are consistent, regardless of gestation, and are not elevated in pregnancy. The current reference values for the diagnosis of OC appear to be appropriate.

  4. Value assignment of nutrient concentrations in five standard reference materials and six reference materials.

    Science.gov (United States)

    Sharpless, K E; Gill, L M

    2000-01-01

    A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of

  5. 76 FR 8989 - Federal Acquisition Regulation; Updated Financial Accounting Standards Board Accounting References

    Science.gov (United States)

    2011-02-16

    ... Acquisition Regulation; Updated Financial Accounting Standards Board Accounting References AGENCIES... Acquisition Regulation (FAR) to update references to authoritative accounting standards owing to the Financial... Accounting Principles (GAAP) (``Codification of GAAP''). DATES: Interested parties should submit written...

  6. 78 FR 37696 - Federal Acquisition Regulation; Updated Postretirement Benefit (PRB) References

    Science.gov (United States)

    2013-06-21

    ... that were deleted in the Financial Accounting Standards Board's (FASB's) Accounting Standards Codification (ASC) of Generally Accepted Accounting Principles (GAAP). The references no longer exist in the..., 2012, to replace the obsolete references to paragraphs 110, 112, and 113 of Financial Accounting...

  7. Standard Reference Development of nuclear material for Tensile and Hardness Test Properties

    International Nuclear Information System (INIS)

    Choo, Y. S.; Kim, D. S.; Yoo, B. O.; Ahn, S. B.; Baik, S. J.; Chun, Y. B.; Kim, K. H.; Hong, K. P.; Ryu, W. S.

    2007-12-01

    Standard reference is a official approved data such a coefficient of physics, approved material properties, and etc., which should be analyzed and evaluated by scientific method to acquire official approval for accuracy and credibility of measured data and information. So it could be used broadly and continuously by various fields of nation and society. It is classified to effective standard reference, verified standard reference, and certified standard reference. There are sixteen fields in designated standard references such a physical chemistry field, material field, metal field, and the others. The standard reference of neutron irradiated nuclear structural material is classified to metal field. This report summarized the whole processes about data collection, data production, data evaluation and the suggestion of details evaluation technical standard for tensile and hardness properties, which were achieved by carry out the project 'nuclear material standard reference development' as a result

  8. Standard Reference Development of nuclear material for Tensile and Hardness Test Properties

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Y. S.; Kim, D. S.; Yoo, B. O.; Ahn, S. B.; Baik, S. J.; Chun, Y. B.; Kim, K. H.; Hong, K. P.; Ryu, W. S

    2007-12-15

    Standard reference is a official approved data such a coefficient of physics, approved material properties, and etc., which should be analyzed and evaluated by scientific method to acquire official approval for accuracy and credibility of measured data and information. So it could be used broadly and continuously by various fields of nation and society. It is classified to effective standard reference, verified standard reference, and certified standard reference. There are sixteen fields in designated standard references such a physical chemistry field, material field, metal field, and the others. The standard reference of neutron irradiated nuclear structural material is classified to metal field. This report summarized the whole processes about data collection, data production, data evaluation and the suggestion of details evaluation technical standard for tensile and hardness properties, which were achieved by carry out the project 'nuclear material standard reference development' as a result.

  9. Validity and Reliability of a Glucometer Against Industry Reference Standards.

    Science.gov (United States)

    Salacinski, Amanda J; Alford, Micah; Drevets, Kathryn; Hart, Sarah; Hunt, Brian E

    2014-01-01

    As an appealing alternative to reference glucose analyzers, portable glucometers are recommended for self-monitoring at home, in the field, and in research settings. The purpose was to characterize the accuracy and precision, and bias of glucometers in biomedical research. Fifteen young (20-36 years; mean = 24.5), moderately to highly active men (n = 10) and women (n = 5), defined by exercising 2 to 3 times a week for the past 6 months, were given an oral glucose tolerance test (OGTT) after an overnight fast. Participants ingested 50, 75, or 150 grams of glucose over a 5-minute period. The glucometer was compared to a reference instrument. The glucometer had 39% of values within 15% of measurements made using the reference instrument ranging from 45.05 to 169.37 mg/dl. There was both a proportional (-0.45 to -0.39) and small fixed (5.06 and 0.90 mg/dl) bias. Results of the present study suggest that the glucometer provided poor validity and reliability results compared to the results provided by the reference laboratory analyzer. The portable glucometers should be used for patient management, but not for diagnosis, treatment, or research purposes. © 2014 Diabetes Technology Society.

  10. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  11. Standard Relativistic Reference Systems and the IAU Framework

    Science.gov (United States)

    Soffel, Michael H.

    2009-05-01

    The classical post-Newtonian (PN) framework is formulated in one single reference system. In a series of papers Damour, Soffel and Xu laid the foundations for a new improved PN framework dealing with the celestial mechanical problem of N gravitationally interacting rotating bodies of arbitrary shape and the problem of astronomical reference systems. In the DSX-framework a total of N+1 reference systems with corresponding coordinates is introduced in the N-body problem: a global one covering the entire model manifold where the translational equations of motion are formulated and one local system attached to each of the N bodies that is co-moving with the body under consideration. In each of these systems the metric tensor is assumed to be of a special form determined by two potentials: a scalar and a vector potential. Theorems are given for the transformations between local and global coordinates and metric potentials. In each of the local systems outside the local body the metric potentials are expressed in terms of Blanchet-Damour mass- and spin-multipole moments. The talk first introduces the original DSX formalism and then concentrates on IAU resolutions related with it. Finally, the formalism is extended to include also effects from the cosmic expansion. The influence of the Hubble expansion on the dynamics of the solar system is explicitly discussed in some detail.

  12. [Application of traditional Chinese medicine reference standards in quality control of Chinese herbal pieces].

    Science.gov (United States)

    Lu, Tu-Lin; Li, Jin-Ci; Yu, Jiang-Yong; Cai, Bao-Chang; Mao, Chun-Qin; Yin, Fang-Zhou

    2014-01-01

    Traditional Chinese medicine (TCM) reference standards plays an important role in the quality control of Chinese herbal pieces. This paper overviewed the development of TCM reference standards. By analyzing the 2010 edition of Chinese pharmacopoeia, the application of TCM reference standards in the quality control of Chinese herbal pieces was summarized, and the problems exiting in the system were put forward. In the process of improving the quality control level of Chinese herbal pieces, various kinds of advanced methods and technology should be used to research the characteristic reference standards of Chinese herbal pieces, more and more reasonable reference standards should be introduced in the quality control system of Chinese herbal pieces. This article discussed the solutions in the aspect of TCM reference standards, and future development of quality control on Chinese herbal pieces is prospected.

  13. New International Reference Standards of Voltage and Resistance.

    Science.gov (United States)

    Sirvastava, V. P.

    1991-01-01

    The introduction of the quantum standards of resistance and voltage, based on the Quantum Hall Effect (QHE) and the Josephson Effect, can be used to establish highly reproducible and uniform representations of the ohm and volt worldwide. Discussed are the QHE and the Josephson Effect. (KR)

  14. Sensitivity analysis of reference evapotranspiration to sensor accuracy

    Science.gov (United States)

    Meteorological sensor networks are often used across agricultural regions to calculate the ASCE Standardized Reference ET Equation, and inaccuracies in individual sensors can lead to inaccuracies in ET estimates. Multiyear datasets from the semi-arid Colorado Agricultural Meteorological (CoAgMet) an...

  15. Iodine in different food articles and standard reference materials

    International Nuclear Information System (INIS)

    Dermelj, M.; Slejkovec, Z.; Byrne, A.R.; Stegnar, P.; Stibilj, V.; Rossbach, M.

    1990-01-01

    The greater part of essential iodine enters living organisms via the food chain. Nevertheless, quantitative data on its concentration in diets, food articles and also in available SRMs are very poor and scarce. This and WHO recommendations on daily allowances of iodine for man via food articles caused an added demand for accurate and reliable determination of iodine in these samples. From this point of view the purpose of the present was to analyse and to establish the concentration levels of total iodine in some food articles, diets, SRMs and candidate reference materials by the use of rapid radiochemical separation, developed in our laboratory. The results were checked by the analysis of SRMs with available certified values for iodine and good agreement is evident. (orig.)

  16. A Standardized Reference Data Set for Vertebrate Taxon Name Resolution.

    Science.gov (United States)

    Zermoglio, Paula F; Guralnick, Robert P; Wieczorek, John R

    2016-01-01

    Taxonomic names associated with digitized biocollections labels have flooded into repositories such as GBIF, iDigBio and VertNet. The names on these labels are often misspelled, out of date, or present other problems, as they were often captured only once during accessioning of specimens, or have a history of label changes without clear provenance. Before records are reliably usable in research, it is critical that these issues be addressed. However, still missing is an assessment of the scope of the problem, the effort needed to solve it, and a way to improve effectiveness of tools developed to aid the process. We present a carefully human-vetted analysis of 1000 verbatim scientific names taken at random from those published via the data aggregator VertNet, providing the first rigorously reviewed, reference validation data set. In addition to characterizing formatting problems, human vetting focused on detecting misspelling, synonymy, and the incorrect use of Darwin Core. Our results reveal a sobering view of the challenge ahead, as less than 47% of name strings were found to be currently valid. More optimistically, nearly 97% of name combinations could be resolved to a currently valid name, suggesting that computer-aided approaches may provide feasible means to improve digitized content. Finally, we associated names back to biocollections records and fit logistic models to test potential drivers of issues. A set of candidate variables (geographic region, year collected, higher-level clade, and the institutional digitally accessible data volume) and their 2-way interactions all predict the probability of records having taxon name issues, based on model selection approaches. We strongly encourage further experiments to use this reference data set as a means to compare automated or computer-aided taxon name tools for their ability to resolve and improve the existing wealth of legacy data.

  17. A Standardized Reference Data Set for Vertebrate Taxon Name Resolution.

    Directory of Open Access Journals (Sweden)

    Paula F Zermoglio

    Full Text Available Taxonomic names associated with digitized biocollections labels have flooded into repositories such as GBIF, iDigBio and VertNet. The names on these labels are often misspelled, out of date, or present other problems, as they were often captured only once during accessioning of specimens, or have a history of label changes without clear provenance. Before records are reliably usable in research, it is critical that these issues be addressed. However, still missing is an assessment of the scope of the problem, the effort needed to solve it, and a way to improve effectiveness of tools developed to aid the process. We present a carefully human-vetted analysis of 1000 verbatim scientific names taken at random from those published via the data aggregator VertNet, providing the first rigorously reviewed, reference validation data set. In addition to characterizing formatting problems, human vetting focused on detecting misspelling, synonymy, and the incorrect use of Darwin Core. Our results reveal a sobering view of the challenge ahead, as less than 47% of name strings were found to be currently valid. More optimistically, nearly 97% of name combinations could be resolved to a currently valid name, suggesting that computer-aided approaches may provide feasible means to improve digitized content. Finally, we associated names back to biocollections records and fit logistic models to test potential drivers of issues. A set of candidate variables (geographic region, year collected, higher-level clade, and the institutional digitally accessible data volume and their 2-way interactions all predict the probability of records having taxon name issues, based on model selection approaches. We strongly encourage further experiments to use this reference data set as a means to compare automated or computer-aided taxon name tools for their ability to resolve and improve the existing wealth of legacy data.

  18. ASC-PROBA Interface Control Document

    DEFF Research Database (Denmark)

    Betto, Maurizio; Jørgensen, John Leif; Jørgensen, Finn E

    1999-01-01

    of Automation of the Technical University of Denmark. The document is structured as follows. First we present the ASC - heritage, system description, performance - then we address more specifically the environmental properties, like the EMC compatibility and thermal characteristics, and the design...... and reliability issues. Section 6 deals with the testing and the calibration procedures and in section 7 the mechanical and electrical interfaces are given. In section 8 and 9 we address issues like manufacturing, transportation and storage and to conclude we review the ASC specifications against the PROBA...

  19. Physical Fitness Reference Standards in French Youth: The BOUGE Program.

    Science.gov (United States)

    Vanhelst, Jérémy; Labreuche, Julien; Béghin, Laurent; Drumez, Elodie; Fardy, Paul S; Chapelot, Didier; Mikulovic, Jacques; Ulmer, Zékya

    2017-06-01

    The aim of this study was to establish sex- and age-specific physical fitness percentiles in French youth. A sample of 11,186 children and adolescents (5,546 boys and 5,640 girls), aged between 10 and 15 years, was assessed in the French national BOUGE study. Participants were tested for their cardiorespiratory fitness, muscular endurance, speed, flexibility, and agility using the following tests: 20-m shuttle run tests, curl-ups test, 50-m sprint test, back-saver sit and reach test, and 10 × 5-m shuttle run test. Percentile values were estimated for French youth as a function of age stratified by sex using the generalized additive model for location, scale, and shape (GAMLSS). In general, physical fitness was better in boys than in girls, except for the back-saver sit and reach test, in which girls performed better. Except for the back-saver sit and reach test and 10 × 5-m shuttle run test, physical fitness performance was significantly associated with age. Sex- and age-specific normative values for physical fitness tests in French youth expressed as percentiles from the fifth to the 95th are provided. Reference values provide normative data for French youth. The data are useful in identifying special needs for appropriate intervention programs.

  20. Semi-automatic construction of reference standards for evaluation of image registration

    NARCIS (Netherlands)

    Murphy, K.; Ginneken, van B.; Klein, S.; Staring, M.; Hoop, de B.J.; Viergever, M.A.; Pluim, J.P.W.

    2011-01-01

    Quantitative evaluation of image registration algorithms is a difficult and under-addressed issue due to the lack of a reference standard in most registration problems. In this work a method is presented whereby detailed reference standard data may be constructed in an efficient semi-automatic

  1. Reference design for the standard mirror hybrid reactor

    Energy Technology Data Exchange (ETDEWEB)

    Bender, D.J.; Fink, J.H.; Galloway, T.R.; Kastenberg, W.E.; Lee, J.D.; Devoto, R.S.; Neef, W.S. Jr.; Schultz, K.R.; Culver, D.W.; Rao, S.B.; Rao, S.R.

    1978-05-22

    This report describes the results of a two-year study by Lawrence Livermore Laboratory and General Atomic Co. to develop a conceptual design for the standard (minimum-B) mirror hybrid reactor. The reactor parameters have been chosen to minimize the cost of producing nuclear fuel (/sup 239/Pu) for consumption in fission power reactors (light water reactors). The deuterium-tritium plasma produces approximately 400 MW of fusion power with a plasma Q of 0.64. The fast-fission blanket, which is fueled with depleted uranium and lithium, generates sufficient tritium to run the reactor, has a blanket energy multiplication of M = 10.4, and has a net fissile breeding ratio of Pu/n = 1.51. The reactor has a net electrical output of 600 MWe, a fissile production of 2000 kg of plutonium per year (at a capacity factor of 0.74), and a net plant efficiency of 0.18. The plasma-containment field is generated by a Yin-Yang magnet using NbTi superconductor, and the neutral beam system uses positive-ion acceleration with beam direct conversion. The spherical blanket is based on gas-cooled fast reactor technology. The fusion components, blanket, and primary heat-transfer loop components are all contained within a prestressed-concrete reactor vessel, which provides magnet restraint and supports the primary heat-transfer loop and the blanket.

  2. Reference design for the standard mirror hybrid reactor

    International Nuclear Information System (INIS)

    Bender, D.J.; Fink, J.H.; Galloway, T.R.; Kastenberg, W.E.; Lee, J.D.; Devoto, R.S.; Neef, W.S. Jr.; Schultz, K.R.; Culver, D.W.; Rao, S.B.; Rao, S.R.

    1978-01-01

    This report describes the results of a two-year study by Lawrence Livermore Laboratory and General Atomic Co. to develop a conceptual design for the standard (minimum-B) mirror hybrid reactor. The reactor parameters have been chosen to minimize the cost of producing nuclear fuel ( 239 Pu) for consumption in fission power reactors (light water reactors). The deuterium-tritium plasma produces approximately 400 MW of fusion power with a plasma Q of 0.64. The fast-fission blanket, which is fueled with depleted uranium and lithium, generates sufficient tritium to run the reactor, has a blanket energy multiplication of M = 10.4, and has a net fissile breeding ratio of Pu/n = 1.51. The reactor has a net electrical output of 600 MWe, a fissile production of 2000 kg of plutonium per year (at a capacity factor of 0.74), and a net plant efficiency of 0.18. The plasma-containment field is generated by a Yin-Yang magnet using NbTi superconductor, and the neutral beam system uses positive-ion acceleration with beam direct conversion. The spherical blanket is based on gas-cooled fast reactor technology. The fusion components, blanket, and primary heat-transfer loop components are all contained within a prestressed-concrete reactor vessel, which provides magnet restraint and supports the primary heat-transfer loop and the blanket

  3. The AscSimulationMode command

    DEFF Research Database (Denmark)

    Jørgensen, John Leif

    1998-01-01

    Complex instruments like the ASC may be quite difficult to test in closed loops. This problem is augmented by the fact, that no direct stimulation of the CHU is possible that will render the full performance, noise-spectrum and real-timeliness with high fidelity. In order to circumvent this impasse...

  4. Comparison Between a Reference Torque Standard Machine and a Deadweight Torque Standard Machine to BE Used in Torque Calibration

    Science.gov (United States)

    Meng, Feng; Zhang, Zhimin; Lin, Jing

    The paper describes the reference torque standard machine with high accuracy and multifunction, developed by our institute, and introduces the structure and working principle of this machine. It has three main functions. The first function is the hydraulic torque wrench calibration function. The second function is torque multiply calibration function. The third function is reference torque standard machine function. We can calibrate the torque multipliers, hydraulic wrenches and transducers by this machine. A comparison experiment has been done between this machine and a deadweight torque standard machine. The consistency between the 30 kNm reference torque machine and the 2000 Nm dead-weight torque standard machine under the claimed uncertainties was verified.

  5. 18 CFR 1300.101 - Cross references to employee ethical conduct standards and other applicable regulations.

    Science.gov (United States)

    2010-04-01

    ... employee ethical conduct standards and other applicable regulations. 1300.101 Section 1300.101 Conservation... TENNESSEE VALLEY AUTHORITY § 1300.101 Cross references to employee ethical conduct standards and other...-wide standards of ethical conduct at 5 CFR part 2635 and to the TVA regulations at 5 CFR part 7901...

  6. Advanced Stirling Convertor (ASC) Development for NASA RPS

    Science.gov (United States)

    Wong, Wayne A.; Wilson, Scott; Collins, Josh

    2014-01-01

    Sunpower's Advanced Stirling Convertor (ASC) initiated development under contract to the NASA Glenn Research Center (GRC) and after a series of successful demonstrations, the ASC began transitioning from a technology development project to flight development project. The ASC has very high power conversion efficiency making it attractive for future Radioisotope Power Systems (RPS) in order to make best use of the low plutonium-238 fuel inventory in the U.S. In recent years, the ASC became part of the NASA-Department of Energy Advanced Stirling Radioisotope Generator (ASRG) Integrated Project. Sunpower held two parallel contracts to produce ASC convertors, one with the Department of Energy/Lockheed Martin to produce the ASC-F flight convertors, and one with NASA GRC for the production of ASC-E3 engineering units, the initial units of which served as production pathfinders. The integrated ASC technical team successfully overcame various technical challenges that led to the completion and delivery of the first two pairs of flight-like ASC-E3 by 2013. However, in late Fall 2013, the DOE initiated termination of the Lockheed Martin ASRG flight development contract driven primarily by budget constraints. NASA continues to recognize the importance of high efficiency ASC power conversion for RPS and continues investment in the technology including the continuation of ASC-E3 production at Sunpower and the assembly of the ASRG Engineering Unit #2. This paper provides a summary of ASC technical accomplishments, overview of tests at GRC, plans for continued ASC production at Sunpower, and status of Stirling technology development.

  7. Setting the standard: The IAEA safety standards set the global reference

    International Nuclear Information System (INIS)

    Williams, L.

    2003-01-01

    For the IAEA, setting and promoting standards for nuclear radiation, waste, and transport safety have been priorities from the start, rooted in the Agency's 1957 Statute. Today, a corpus of international standards are in place that national regulators and industries in many countries are applying, and more are being encouraged and assisted to follow them. Considerable work is done to keep safety standards updated and authoritative. They cover five main areas: the safety of nuclear facilities; radiation protection and safety of radiation sources; safe management of radioactive waste; safe transport of radioactive material; and thematic safety areas, such as emergency preparedness or legal infrastructures. Overall, the safety standards reflect an international consensus on what constitutes a high level of safety for protecting people and the environment. All IAEA Member States can nominate experts for the Agency standards committees and provide comments on draft standards. Through this ongoing cycle of review and feedback, the standards are refined, updated, and extended where needed

  8. A Comparative Study of Standardized Infinity Reference and Average Reference for EEG of Three Typical Brain States

    Directory of Open Access Journals (Sweden)

    Gaoxing Zheng

    2018-03-01

    Full Text Available The choice of different reference electrodes plays an important role in deciphering the functional meaning of electroencephalography (EEG signals. In recent years, the infinity zero reference using the reference electrode standard technique (REST has been increasingly applied, while the average reference (AR was generally advocated as the best available reference option in previous classical EEG studies. Here, we designed EEG experiments and performed a direct comparison between the influences of REST and AR on EEG-revealed brain activity features for three typical brain behavior states (eyes-closed, eyes-open and music-listening. The analysis results revealed the following observations: (1 there is no significant difference in the alpha-wave-blocking effect during the eyes-open state compared with the eyes-closed state for both REST and AR references; (2 there was clear frontal EEG asymmetry during the resting state, and the degree of lateralization under REST was higher than that under AR; (3 the global brain functional connectivity density (FCD and local FCD have higher values for REST than for AR under different behavior states; and (4 the value of the small-world network characteristic in the eyes-closed state is significantly (in full, alpha, beta and gamma frequency bands higher than that in the eyes-open state, and the small-world effect under the REST reference is higher than that under AR. In addition, the music-listening state has a higher small-world network effect than the eyes-closed state. The above results suggest that typical EEG features might be more clearly presented by applying the REST reference than by applying AR when using a 64-channel recording.

  9. From plastic to gold: a unified classification scheme for reference standards in medical image processing

    Science.gov (United States)

    Lehmann, Thomas M.

    2002-05-01

    Reliable evaluation of medical image processing is of major importance for routine applications. Nonetheless, evaluation is often omitted or methodically defective when novel approaches or algorithms are introduced. Adopted from medical diagnosis, we define the following criteria to classify reference standards: 1. Reliance, if the generation or capturing of test images for evaluation follows an exactly determined and reproducible protocol. 2. Equivalence, if the image material or relationships considered within an algorithmic reference standard equal real-life data with respect to structure, noise, or other parameters of importance. 3. Independence, if any reference standard relies on a different procedure than that to be evaluated, or on other images or image modalities than that used routinely. This criterion bans the simultaneous use of one image for both, training and test phase. 4. Relevance, if the algorithm to be evaluated is self-reproducible. If random parameters or optimization strategies are applied, reliability of the algorithm must be shown before the reference standard is applied for evaluation. 5. Significance, if the number of reference standard images that are used for evaluation is sufficient large to enable statistically founded analysis. We demand that a true gold standard must satisfy the Criteria 1 to 3. Any standard only satisfying two criteria, i.e., Criterion 1 and Criterion 2 or Criterion 1 and Criterion 3, is referred to as silver standard. Other standards are termed to be from plastic. Before exhaustive evaluation based on gold or silver standards is performed, its relevance must be shown (Criterion 4) and sufficient tests must be carried out to found statistical analysis (Criterion 5). In this paper, examples are given for each class of reference standards.

  10. Spatial variability in sensitivity of reference crop ET to accuracy of climate data in the Texas High Plains

    Science.gov (United States)

    A detailed sensitivity analysis was conducted to determine the relative effects of measurement errors in climate data input parameters on the accuracy of calculated reference crop evapotranspiration (ET) using the ASCE-EWRI Standardized Reference ET Equation. Data for the period of 1995 to 2008, fro...

  11. The ASC Sequoia Programming Model

    Energy Technology Data Exchange (ETDEWEB)

    Seager, M

    2008-08-06

    developed with multiple 'cores' in them and called Symmetric Multi-Processor or Shared Memory Processor (SMP) systems. The parallel revolution had begun. The Laboratory started a small 'parallel processing project' in 1983 to study the new technology and its application to scientific computing with four people: Tim Axelrod, Pete Eltgroth, Paul Dubois and Mark Seager. Two years later, Eugene Brooks joined the team. This team focused on Unix and 'killer micro' SMPs. Indeed, Eugene Brooks was credited with coming up with the 'Killer Micro' term. After several generations of SMP platforms (e.g., Sequent Balance 8000 with 8 33MHz MC32032s, Allian FX8 with 8 MC68020 and FPGA based Vector Units and finally the BB&N Butterfly with 128 cores), it became apparent to us that the killer micro revolution would indeed take over Crays and that we definitely needed a new programming and systems model. The model developed by Mark Seager and Dale Nielsen focused on both the system aspects (Slide 3) and the code development aspects (Slide 4). Although now succinctly captured in two attached slides, at the time there was tremendous ferment in the research community as to what parallel programming model would emerge, dominate and survive. In addition, we wanted a model that would provide portability between platforms of a single generation but also longevity over multiple--and hopefully--many generations. Only after we developed the 'Livermore Model' and worked it out in considerable detail did it become obvious that what we came up with was the right approach. In a nutshell, the applications programming model of the Livermore Model posited that SMP parallelism would ultimately not scale indefinitely and one would have to bite the bullet and implement MPI parallelism within the Integrated Design Code (IDC). We also had a major emphasis on doing everything in a completely standards based, portable methodology with POSIX/Unix as the target

  12. Improving the efficiency of quantitative (1)H NMR: an innovative external standard-internal reference approach.

    Science.gov (United States)

    Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V

    2014-01-01

    The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. 78 FR 21850 - Federal Motor Vehicle Safety Standards; Matters Incorporated by Reference

    Science.gov (United States)

    2013-04-12

    ... to the 1985 Annual Book of ASTM Standards, Vol. 05.04, ``Test Methods for Rating Motor, Diesel... for Rating Motor, Diesel, Aviation Fuels, A2. Reference Materials and Blending Accessories, (``ASTM... [Docket No. NHTSA-2011-0185] RIN 2127-AL25 Federal Motor Vehicle Safety Standards; Matters Incorporated by...

  14. Referring to IAEA system to improve Chinese standards system on nuclear and radiation safety

    International Nuclear Information System (INIS)

    Shang Zhaorong; Wang Wenhai

    2010-01-01

    Referring to the standards system of IAEA, to build and improve the Chinese standards system of nuclear and radiation safety is a long term infrastructure work and an assurance to keep sustainable development of nuclear industry and nuclear technology application in China. The paper analyses the current main problem, and gives some suggestions on developing and improving the system. (authors)

  15. Compilation of elemental concentration data for NBS Biological and Environmental Standard Reference Materials

    International Nuclear Information System (INIS)

    Gladney, E.S.

    1980-07-01

    Concentration data on up to 76 elementals in 19 NBS Standard Reference Materials have been collected from 325 journal articles and technical reports. These data are summarized into mean +- one standard deviation values and compared with available data from NBS and other review articles. Data are presented on the analytical procedures employed and all raw data are presented in appendixes

  16. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  17. Characterization of reference standards for dirt by Laser Ablation Induced Photoacoustics (LAIP)

    International Nuclear Information System (INIS)

    Orzi, D J O; Bilmes, G M; Morel, E N; Torga, J R; Roviglione, A N

    2010-01-01

    Measurements of surface cleanliness and dirt characterization are important problems in a wide range of processes in industry and production. Standard methods are in most cases cumbersome laboratory procedures that must be performed out of the production lines. Instruments and methods for cleanliness determination and dirt characterization require reference standards for calibration. For that purpose we built a possible dirt reference standard (DRS) made by films of graphite grease subjected to heat treatment for mechanical stabilization. The DRS characterization was performed by Laser Ablation Induced Photoacoustics (LAIP). The measurement of the thickness of the films was made by low-coherence interferometry.

  18. Neutron activation analysis of reference materials by the k sub 0 standardization and relative methods

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, M C; Martinho, E [LNETI/ICEN, Sacavem (Portugal)

    1989-04-15

    Instrumental neutron activation analysis with the k{sub o}-standardization method was applied to eight geological, environmental and biological reference materials, including leaves, blood, fish, sediments, soils and limestone. To a first approximation, the results were normally distributed around the certified values with a standard deviation of 10%. Results obtained by using the relative method based on well characterized multi-element standards for IAEA CRM Soil-7 are reported.

  19. ASC deficiency suppresses proliferation and prevents medulloblastoma incidence.

    Science.gov (United States)

    Knight, E R W; Patel, E Y; Flowers, C A; Crowther, A J; Ting, J P; Miller, C R; Gershon, T R; Deshmukh, M

    2015-01-15

    Apoptosis-associated speck-like protein containing a caspase recruitment domain (ASC) is silenced by promoter methylation in many types of tumors, yet ASC's role in most cancers remains unknown. Here, we show that ASC is highly expressed in a model of medulloblastoma, the most common malignant pediatric brain cancer; ASC is also expressed in human medulloblastomas. Importantly, while ASC deficiency did not affect normal cerebellar development, ASC knockout mice on the Smoothened (ND2:SmoA1) transgenic model of medulloblastoma exhibited a profound reduction in medulloblastoma incidence and a delayed tumor onset. A similar decrease in tumorigenesis with ASC deficiency was also seen in the hGFAP-Cre:SmoM2 mouse model of medulloblastoma. Interestingly, hyperproliferation of the external granule layer (EGL) was comparable at P20 in both wild-type and ASC-deficient SmoA1 mice. However, while the apoptosis and differentiation markers remained unchanged at this age, proliferation makers were decreased, and the EGL was reduced in thickness and area by P60. This reduction in proliferation with ASC deficiency was also seen in isolated SmoA1 cerebellar granule precursor cells in vitro, indicating that the effect of ASC deletion on proliferation was cell autonomous. Interestingly, ASC-deficient SmoA1 cerebella exhibited disrupted expression of genes in the transforming growth factor-β pathway and increased level of nuclear Smad3. Taken together, these results demonstrate an unexpected role for ASC in Sonic hedgehog-driven medulloblastoma tumorigenesis, thus identifying ASC as a promising novel target for antitumor therapy.

  20. Determination of multielement in optical waveguide and standard reference materials by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Kobayashi, K.; Kudo, K.

    1979-01-01

    Trace amounts of transition elements (Co, Cr, Cu, Fe, Mn and V) and other seven elements in optical waveguide samples were determined by INAA. The contents of impurities in ultre-pure materials are less than those of high-purity materials and of G.R. grade. The increase of contamination of trace transition elements and iridium from furnace or crucible are observed in the production of optical glass fibers. Up to seventeen elements were determined in five NBS biological standard reference materials: Oyster Tissue: SRM-1566, Brewers Yeast: SRM-1569, Spinach: SRM-1570, Orchard Leaves: SRM-1571 and Tuna Fish, and in four Japanese biological standard reference materials: Tea Leaves B and C, Pepperbush and Shark Meat. The analytical results in NBS and Japanese standard reference materials are in good agreement with published values and certified values by NBS. (author)

  1. Measurement of the depth of narrow slotted sections in eddy current reference standards

    Science.gov (United States)

    Kim, Young-Joo; Kim, Young-gil; Ahn, Bongyoung; Yoon, Dong-Jin

    2007-02-01

    The dimensions of the slots in eddy current (EC) reference standards are too narrow to be measured by general depth measurement methods such as the optical (laser) or stylus methods. However, measurement of the dimensions of the machined slots is a prerequisite to using the blocks as references. The present paper suggests a measurement method for the slotted section using an ultrasonic test. The width and depth of the slots measured in our study are roughly 0.1 mm and 0.5 mm, respectively. The time of flight (TOF) of the ultrasonic wave was measured precisely. The ultrasonic velocity in the material of the EC reference standard was calculated with the measured values of the TOF and its thickness. Reflected waves from the tip of the slot and the bottom surface of the EC standard were successfully classified. Using this method we have successfully determined the depth of the slotted section.

  2. Standard digital reference images for investment steel castings for aerospace applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The digital reference images provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in thin-wall steel investment castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct digital reference images which illustrate the discontinuity types and severity levels. They are intended to provide the following: 1.1.1 A guide enabling recognition of thin-wall steel casting discontinuities and their differentiation both as to type and degree through digital radiographic examination. 1.1.2 Example digital radiographic illustrations of discontinuities and a nomenclature for reference in acceptance standards, specifications and drawings. 1.2 Two illustration categories are covered as follows: 1.2.1 Graded—Six common discontinuity types each illustrated in eight degrees of progressively increasing severity. 1.2.2 Ungraded—Twelve single illustrations of additional discontinuity types and of patterns and imper...

  3. The use of high accuracy NAA for the certification of NIST botanical standard reference materials

    International Nuclear Information System (INIS)

    Becker, D.A.; Greenberg, R.R.; Stone, S.F.

    1992-01-01

    Neutron activation analysis is one of many analytical techniques used at the National Institute of Standards and Technology (NIST) for the certification of NIST Standard Reference Materials (SRMs). NAA competes favorably with all other techniques because of it's unique capabilities for high accuracy even at very low concentrations for many elements. In this paper, instrumental and radiochemical NAA results are described for 25 elements in two new NIST SRMs, SRM 1515 (Apple Leaves) and SRM 1547 (Peach Leaves), and are compared to the certified values for 19 elements in these two new botanical reference materials. (author) 7 refs.; 4 tabs

  4. ASC Trilab L2 Codesign Milestone 2015

    Energy Technology Data Exchange (ETDEWEB)

    Trott, Christian Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hammond, Simon David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dinge, Dennis [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lin, Paul T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vaughan, Courtenay T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Cook, Jeanine [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Edwards, Harold C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rajan, Mahesh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hoekstra, Robert J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    For the FY15 ASC L2 Trilab Codesign milestone Sandia National Laboratories performed two main studies. The first study investigated three topics (performance, cross-platform portability and programmer productivity) when using OpenMP directives and the RAJA and Kokkos programming models available from LLNL and SNL respectively. The focus of this first study was the LULESH mini-application developed and maintained by LLNL. In the coming sections of the report the reader will find performance comparisons (and a demonstration of portability) for a variety of mini-application implementations produced during this study with varying levels of optimization. Of note is that the implementations utilized including optimizations across a number of programming models to help ensure claims that Kokkos can provide native-class application performance are valid. The second study performed during FY15 is a performance assessment of the MiniAero mini-application developed by Sandia. This mini-application was developed by the SIERRA Thermal-Fluid team at Sandia for the purposes of learning the Kokkos programming model and so is available in only a single implementation. For this report we studied its performance and scaling on a number of machines with the intent of providing insight into potential performance issues that may be experienced when similar algorithms are deployed on the forthcoming Trinity ASC ATS platform.

  5. Initial testing of a neutron activation analysis system by analysing standard reference materials

    International Nuclear Information System (INIS)

    Suhaimi Hamzah; Roslan Idris; Abdul Khalik Haji Wood; Che Seman Mahmood; Abdul Rahim Mohamad Noor.

    1983-01-01

    This paper describes the data acquisition and processing system in our laboratories (ND6600), the methods of activation analysis and the results obtained from our analysis of IAEA standard reference material (SL-l lake sediments and NBS coal ash 1632a). These standards were analysed in order to check the capability of the system, which was designed in such a way as to enable the user to independently collect and process data from multiple radiation detectors. (author)

  6. Evaluation of a new 10 mA DC current reference standard

    CERN Document Server

    Fernqvist, G; Power, F

    2002-01-01

    A new DC current reference standard has been developed as a component in a Current calibration hierarchy in the LHC project at CERN. The standard provides 10 mA DC current with an accuracy less than 0.5 ppm, drift less than 2 ppm/year and compliance error less than 0.1 ppm for 0-10 V. The paper gives the results from two years evaluation of a series of 5 units.

  7. Advanced Stirling Convertor (ASC) Technology Maturation in Preparation for Flight

    Science.gov (United States)

    Wong, Wayne A.; Cornell, Peggy A.

    2012-01-01

    The Advanced Stirling Convertor (ASC) is being developed by an integrated team of Sunpower and National Aeronautics and Space Administration s (NASA s) Glenn Research Center (GRC). The ASC development, funded by NASA s Science Mission Directorate, started as a technology development effort in 2003 and has since evolved through progressive convertor builds and successful testing to demonstrate high conversion efficiency, low mass, and capability to meet long-life Radioisotope Power System (RPS) requirements. The technology has been adopted by the Department of Energy and Lockheed Martin Space Systems Company s Advanced Stirling Radioisotope Generator (ASRG), which has been selected for potential flight demonstration on Discovery 12. This paper provides an overview of the status of ASC development including the most recent ASC-E2 convertors that have been delivered to GRC and an introduction to the ASC-E3 and ASC flight convertors that Sunpower will build next. The paper also describes the technology maturation and support tasks being conducted at GRC to support ASC and ASRG development in the areas of convertor and generator extended operation, high-temperature materials, heater head life assessment, organics, nondestructive inspection, spring fatigue testing, and other reliability verification tasks.

  8. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  9. Measurement standards and the general problem of reference points in chemical analysis

    International Nuclear Information System (INIS)

    Richter, W.; Dube, G.

    2002-01-01

    Besides the measurement standards available in general metrology in the form of the realisations of the units of measurement, measurement standards of chemical composition are needed for the vast field of chemical measurement (measurements of the chemical composition), because it is the main aim of such measurements to quantify non-isolated substances, often in complicated matrices, to which the 'classical' measurement standards and their lower- level derivatives are not directly applicable. At present, material artefacts as well as standard measurement devices serve as chemical measurement standards. These are measurement standards in the full metrological sense only, however, if they are firmly linked to the SI unit in which the composition represented by the standard is expressed. This requirement has the consequence that only a very restricted number of really reliable chemical measurement standards exist at present. Since it is very difficult and time consuming to increase this number substantially and, on the other hand, reliable reference points are increasingly needed for all kinds of chemical measurements, primary methods of measurement and high-level reference measurements will play an increasingly important role for the establishment of worldwide comparability and hence mutual acceptance of chemical measurement results. (author)

  10. Standard reference data for the air-liquid and vapor-liquid surface tension of benzene

    Czech Academy of Sciences Publication Activity Database

    Součková, Monika; Klomfar, Jaroslav; Pátek, Jaroslav

    2013-01-01

    Roč. 356, October (2013), s. 329-337 ISSN 0378-3812 R&D Projects: GA ČR GA101/09/0010 Institutional support: RVO:61388998 Keywords : benzene * surface tension * experimental data * standard reference data Subject RIV: BJ - Thermodynamics Impact factor: 2.241, year: 2013 http://www.sciencedirect.com/science/article/pii/S0378381213004196

  11. Body Parameters of Czech Breastfed Children Compared to the Czech References and WHO Growth Standards

    Czech Academy of Sciences Publication Activity Database

    Riedlová, J.; Vignerová, J.; Paulová, M.; Musil, V.; Brabec, Marek; Schneidrová, D.

    2017-01-01

    Roč. 44, č. 7 (2017), s. 593-599 ISSN 0301-4460 Grant - others:GA MZd(CZ) NS9974 Institutional support: RVO:67985807 Keywords : breastfed children * Czech reference * Growth charts * WHO growth standards Subject RIV: BB - Applied Statistics, Operational Research OBOR OECD: Statistics and probability Impact factor: 1.240, year: 2016

  12. 78 FR 57293 - Distribution of Reference Biological Standards and Biological Preparations

    Science.gov (United States)

    2013-09-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES 42 CFR Part 7 [Docket No. CDC-2013-0013] RIN 0920-AA52 Distribution of Reference Biological Standards and Biological Preparations AGENCY: Centers for Disease Control and Prevention (HHS/CDC), Department of Health and Human Services (HHS). ACTION: Confirmation of...

  13. 78 FR 47319 - Fee Schedule for Reference Biological Standards and Biological Preparations

    Science.gov (United States)

    2013-08-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Fee Schedule for Reference Biological Standards and Biological Preparations AGENCY: Centers for Disease Control and... for Disease Control and Prevention (CDC), located within the Department of Health and Human Services...

  14. Probability-Based Design Criteria of the ASCE 7 Tsunami Loads and Effects Provisions (Invited)

    Science.gov (United States)

    Chock, G.

    2013-12-01

    Mitigation of tsunami risk requires a combination of emergency preparedness for evacuation in addition to providing structural resilience of critical facilities, infrastructure, and key resources necessary for immediate response and economic and social recovery. Critical facilities would include emergency response, medical, tsunami refuges and shelters, ports and harbors, lifelines, transportation, telecommunications, power, financial institutions, and major industrial/commercial facilities. The Tsunami Loads and Effects Subcommittee of the ASCE/SEI 7 Standards Committee is developing a proposed new Chapter 6 - Tsunami Loads and Effects for the 2016 edition of the ASCE 7 Standard. ASCE 7 provides the minimum design loads and requirements for structures subject to building codes such as the International Building Code utilized in the USA. In this paper we will provide a review emphasizing the intent of these new code provisions and explain the design methodology. The ASCE 7 provisions for Tsunami Loads and Effects enables a set of analysis and design methodologies that are consistent with performance-based engineering based on probabilistic criteria. . The ASCE 7 Tsunami Loads and Effects chapter will be initially applicable only to the states of Alaska, Washington, Oregon, California, and Hawaii. Ground shaking effects and subsidence from a preceding local offshore Maximum Considered Earthquake will also be considered prior to tsunami arrival for Alaska and states in the Pacific Northwest regions governed by nearby offshore subduction earthquakes. For national tsunami design provisions to achieve a consistent reliability standard of structural performance for community resilience, a new generation of tsunami inundation hazard maps for design is required. The lesson of recent tsunami is that historical records alone do not provide a sufficient measure of the potential heights of future tsunamis. Engineering design must consider the occurrence of events greater than

  15. Design and evaluation of a 10-mA DC current reference standard

    CERN Document Server

    Fernqvist, G; Pickering, J; Power, F

    2003-01-01

    A new DC current reference standard has been developed for high- current power converter calibration in the large hadron collider (LHC) project at the European Organization for Nuclear Research (CERN). This standard provides a near ideal 10-mA DC current with long-term drift of one part in 10/sup 6/ per year. The paper describes the requirements and the detailed design and evaluation of the unit. Since similar 10-V standards are commercially available, the paper concentrates on the unique current output capability of this device. (4 refs).

  16. ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eley, Charles [Eley and Associates, Hobe Sound, FL (United States)

    2017-09-29

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

  17. ASC FY17 Implementation Plan, Rev. 1

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, P. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-06-14

    The Stockpile Stewardship Program (SSP) is an integrated technical program for maintaining the safety, surety, and reliability of the U.S. nuclear stockpile. The SSP uses nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. It includes stockpile surveillance, experimental research, development and engineering programs, and an appropriately scaled production capability to support stockpile requirements. This integrated national program requires the continued use of experimental facilities and programs, and the computational capabilities to support these programs. The Advanced Simulation and Computing Program (ASC) is a cornerstone of the SSP, providing simulation capabilities and computational resources that support annual stockpile assessment and certification, study advanced nuclear weapons design and manufacturing processes, analyze accident scenarios and weapons aging, and provide the tools to enable stockpile Life Extension Programs (LEPs) and the resolution of Significant Finding Investigations (SFIs). This requires a balance of resources, including technical staff, hardware, simulation software, and computer science solutions.

  18. How many records should be used in ASCE/SEI-7 ground motion scaling procedure?

    Science.gov (United States)

    Reyes, Juan C.; Kalkan, Erol

    2012-01-01

    U.S. national building codes refer to the ASCE/SEI-7 provisions for selecting and scaling ground motions for use in nonlinear response history analysis of structures. Because the limiting values for the number of records in the ASCE/SEI-7 are based on engineering experience, this study examines the required number of records statistically, such that the scaled records provide accurate, efficient, and consistent estimates of “true” structural responses. Based on elastic–perfectly plastic and bilinear single-degree-of-freedom systems, the ASCE/SEI-7 scaling procedure is applied to 480 sets of ground motions; the number of records in these sets varies from three to ten. As compared to benchmark responses, it is demonstrated that the ASCE/SEI-7 scaling procedure is conservative if fewer than seven ground motions are employed. Utilizing seven or more randomly selected records provides more accurate estimate of the responses. Selecting records based on their spectral shape and design spectral acceleration increases the accuracy and efficiency of the procedure.

  19. 45 CFR 680.10 - Definitions; cross-references to employee ethical conduct standards and financial disclosure...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Definitions; cross-references to employee ethical... Foundation § 680.10 Definitions; cross-references to employee ethical conduct standards and financial...-references to employee ethical conduct standards and financial disclosure regulations. Members of the...

  20. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  1. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    International Nuclear Information System (INIS)

    Williams, R.W.; Gaffney, A.M.; Kristo, M.J.; Hutcheon, I.D.

    2009-01-01

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the 230 Th- 234 U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial 230 Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U 3 O 8 ) may be assumed with confidence. We present here 230 Th- 234 U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history

  2. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    Energy Technology Data Exchange (ETDEWEB)

    Williams, R W; Gaffney, A M; Kristo, M J; Hutcheon, I D

    2009-05-28

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.

  3. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-01

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

  4. Test Hardware Design for Flightlike Operation of Advanced Stirling Convertors (ASC-E3)

    Science.gov (United States)

    Oriti, Salvatore M.

    2012-01-01

    NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, the Thermal Energy Conversion branch at GRC has been conducting extended operation of a multitude of free-piston Stirling convertors. The goal of this effort is to generate long-term performance data (tens of thousands of hours) simultaneously on multiple units to build a life and reliability database. The test hardware for operation of these convertors was designed to permit in-air investigative testing, such as performance mapping over a range of environmental conditions. With this, there was no requirement to accurately emulate the flight hardware. For the upcoming ASC-E3 units, the decision has been made to assemble the convertors into a flight-like configuration. This means the convertors will be arranged in the dual-opposed configuration in a housing that represents the fit, form, and thermal function of the ASRG. The goal of this effort is to enable system level tests that could not be performed with the traditional test hardware at GRC. This offers the opportunity to perform these system-level tests much earlier in the ASRG flight development, as they would normally not be performed until fabrication of the qualification unit. This paper discusses the requirements, process, and results of this flight-like hardware design activity.

  5. Measuring the activity of BioBrick promoters using an in vivo reference standard

    Directory of Open Access Journals (Sweden)

    Kelly Jason R

    2009-03-01

    Full Text Available Abstract Background The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick™ standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories. Results We found that the absolute activity of BioBrick promoters varies across experimental conditions and measurement instruments. We choose one promoter (BBa_J23101 to serve as an in vivo reference standard for promoter activity. We demonstrated that, by measuring the activity of promoters relative to BBa_J23101, we could reduce variation in reported promoter activity due to differences in test conditions and measurement instruments by ~50%. We defined a Relative Promoter Unit (RPU in order to report promoter characterization data in compatible units and developed a measurement kit so that researchers might more easily adopt RPU as a standard unit for reporting promoter activity. We distributed a set of test promoters to multiple labs and found good agreement in the reported relative activities of promoters so measured. We also characterized the relative activities of a reference collection of BioBrick promoters in order to further support adoption of RPU-based measurement standards. Conclusion Relative activity measurements based on an in vivoreference standard enables improved measurement of promoter activity given variation in measurement

  6. 18 CFR 38.2 - Incorporation by reference of North American Energy Standards Board Wholesale Electric Quadrant...

    Science.gov (United States)

    2010-04-01

    ... reference of North American Energy Standards Board Wholesale Electric Quadrant standards. 38.2 Section 38.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY... UTILITIES § 38.2 Incorporation by reference of North American Energy Standards Board Wholesale Electric...

  7. Platinum stable isotope analysis of geological standard reference materials by double-spike MC-ICPMS

    DEFF Research Database (Denmark)

    Creech, John Benjamin; Baker, J. A.; Handler, M. R.

    2014-01-01

    . Double-spiking of samples was carried out prior to digestion and chemical separation to correct for any mass-dependent fractionation that may occur due to incomplete recovery of Pt. Samples were digested using a NiS fire assay method, which pre-concentrates Pt into a metallic bead that is readily...... metal standard solution doped with a range of synthetic matrices and results in Pt yields of ≥90% with purity of ≥95%. Using this chemical separation technique, we have separated Pt from 11 international geological standard reference materials comprising of PGE ores, mantle rocks, igneous rocks and one...

  8. Stability of Working Reference Standards for Hybrid K-Edge Densitometer Quality Assurance

    International Nuclear Information System (INIS)

    Guzzardo, T.; Pickett, C.A.; McElroy, R.; Croft, S.; Garrison, J.; Venkataraman, R.

    2015-01-01

    The relatively short working life of aqueous solution standards of actinides for the calibration and quality control of Hybrid K-Edge Densitometer (HKED) measurements necessitates the development of a stable matrix material less susceptible to degradation. Degradation in the form of evaporation, radiolysis, settling, sloshing, and sediment formation can all reduce the reliability and working life of an aqueous standard. These factors make aqueous solutions inadequate for long-term quality assurance measurements designed to detect weak or subtle trends in system performance. Epoxy, studied here, is an alternative matrix material that may be less vulnerable to degradation. An additional benefit of epoxy is that standards can easily be characterized as sealed sources which allows for simplified administrative controls during shipping and storage. The stability of working reference standards consisting of U 3 O 8 in an epoxy matrix for use in the HKED has been tracked for over three years through repeated X-ray Fluorescence (XRF) and K-Edge (KED) measurements. A set of six epoxy standards ranging in concentration from 1 g/l to 76 g/l uranium were determined to be stable, within the expected accuracy of the system, over the period of analysis. During this time, no effort was made to enhance the stability of the epoxy standards; the radial measurement position was not controlled and in the middle of the analysis period the HKED system and standards were shipped from the vendor's factory to the customer. Epoxy standards afford numerous benefits over those created from aqueous solutions and should be considered when developing HKED standards for quality assurance measurements. The stability of the epoxy allows the development of working standards of a stability and robustness sufficient for use in a proposed international round-robin exercise based on the exchange of such standards. (author)

  9. Anthropometry as a tool for measuring malnutrition: impact of the new WHO growth standards and reference.

    Science.gov (United States)

    Duggan, M B

    2010-01-01

    Anthropometry is a useful tool, both for monitoring growth and for nutritional assessment. The publication by WHO of internationally agreed growth standards in 1983 facilitated comparative nutritional assessment and the grading of childhood malnutrition. New growth standards for children under 5 years and growth reference for children aged 5-19 years have recently (2006 and 2007) been published by WHO. Growth of children growth reference study involving children from six countries, selected for optimal child-rearing practices (breastfeeding, non-smoking mothers). They therefore constitute a growth standard. Growth data for older children were drawn from existing US studies, and upward skewing was avoided by excluding overweight subjects. These constitute a reference. More indicators are now included to describe optimal early childhood growth and development, e.g. BMI for age and MUAC for age. The growth reference for older children (2007) focuses on linear growth and BMI; weight-for-age data are age-limited and weight-for-height is omitted. Differences in the 2006 growth pattern from the previous reference for children toddler. The spread of values for height and weight for height is narrower in the 2006 dataset, such that the lower limit of the normal range for both indices is set higher than in the previous dataset. This means that a child will be identified as moderately or severely underweight for height (severe acute malnutrition) at a greater weight for height than previously. The implications for services for malnourished children have been recognised and strategies devised. The emphasis on BMI-for-age as the indicator for thinness and obesity in older children is discussed. The complexity of calculations for health cadres without mathematical backgrounds or access to calculation software is also an issue. It is possible that the required charts and tables may not be accessible to those working in traditional health/nutrition services which are often poorly

  10. A new large-volume metal reference standard for radioactive waste management.

    Science.gov (United States)

    Tzika, F; Hult, M; Stroh, H; Marissens, G; Arnold, D; Burda, O; Kovář, P; Suran, J; Listkowska, A; Tyminski, Z

    2016-03-01

    A new large-volume metal reference standard has been developed. The intended use is for calibration of free-release radioactivity measurement systems and is made up of cast iron tubes placed inside a box of the size of a Euro-pallet (80 × 120 cm). The tubes contain certified activity concentrations of (60)Co (0.290 ± 0.006 Bq g(-1)) and (110m)Ag (3.05 ± 0.09 Bq g(-1)) (reference date: 30 September 2013). They were produced using centrifugal casting from a smelt into which (60)Co was first added and then one piece of neutron irradiated silver wire was progressively diluted. The iron castings were machined to the desirable dimensions. The final material consists of 12 iron tubes of 20 cm outer diameter, 17.6 cm inner diameter, 40 cm length/height and 245.9 kg total mass. This paper describes the reference standard and the process of determining the reference activity values. © The Author 2015. Published by Oxford University Press.

  11. Measurement of polybrominated diphenyl ethers in environmental matrix standard reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, H.; Schantz, M.; Wise, S. (National Institute of Standards and Technology)

    2004-09-15

    Polybrominated diphenyl ethers (PBDEs) are a class of emerging contaminants of concern as many studies have now demonstrated that these compounds are bioaccumulative, persistent and increasing in concentration in the environment. PBDEs are being detected in almost every environmental sample examined, and they have even been measured in samples collected in the Arctic, further demonstrating their persistence and potential for long range transport. More and more studies are continuing to examine the fate and transport of these flame retardant compounds in environmental samples and as such, reference materials are needed to provide quality control on these measurements. The National Institute of Standards and Technology (NIST) supports a national Standard Reference Material (SRM) program for measurement of organic contaminants such as PCBs, PAHs and chlorinated pesticides in environmental matrices. This current study was undertaken to provide reference measurements for PBDEs in selected SRMs that are currently used by various laboratories throughout the United States. These SRMs include matrices such as marine mammal blubber, lake trout tissue, mussel tissue, sediment, house dust and human serum. We report here reference values for 22 PBDE congeners that have been quantified in these seven types of SRMs.

  12. Procedure and reference standard to determine the structural resolution in coordinate metrology

    Science.gov (United States)

    Illemann, Jens; Bartscher, Markus; Jusko, Otto; Härtig, Frank; Neuschaefer-Rube, Ulrich; Wendt, Klaus

    2014-06-01

    A new procedure and reference standards for specifying the structural resolution in coordinate metrology traceable to the SI unit the metre are proposed. With the definition of the structural resolution, a significant gap will be closed to complete ‘acceptance and verification tests’ of the coordinate measuring systems (CMSs) which are specified in the ISO 10360 series dealing with tactile sensors, optical sensors, and x-ray computed tomography measurement systems (CTs). The proposed new procedure uses reference standards with circular rounded edges. The idea is to measure the radius of curvature on a calibrated round edge structure. From the deviation between the measured and the calibrated radius, an analogue Gaussian broadening of the measurement system is determined. This value is a well-defined and easy-to-apply measure to define the structural resolution for dimensional measurements. It is applicable to CMSs which are based on different sensing principles, e.g. tactile, optical and CT systems. On the other hand, it has a physical meaning similar to the classical optical point-spread function. It makes it possible to predict which smallest details the CMS is capable of measuring reliably for an arbitrary object shape. The theoretical background of the new procedure is given, an appropriate reference standard is described and comparative, quantitative measurement data of CMSs featuring different sensors are shown.

  13. MATLAB Toolboxes for Reference Electrode Standardization Technique (REST) of Scalp EEG.

    Science.gov (United States)

    Dong, Li; Li, Fali; Liu, Qiang; Wen, Xin; Lai, Yongxiu; Xu, Peng; Yao, Dezhong

    2017-01-01

    Reference electrode standardization technique (REST) has been increasingly acknowledged and applied as a re-reference technique to transform an actual multi-channels recordings to approximately zero reference ones in electroencephalography/event-related potentials (EEG/ERPs) community around the world in recent years. However, a more easy-to-use toolbox for re-referencing scalp EEG data to zero reference is still lacking. Here, we have therefore developed two open-source MATLAB toolboxes for REST of scalp EEG. One version of REST is closely integrated into EEGLAB, which is a popular MATLAB toolbox for processing the EEG data; and another is a batch version to make it more convenient and efficient for experienced users. Both of them are designed to provide an easy-to-use for novice researchers and flexibility for experienced researchers. All versions of the REST toolboxes can be freely downloaded at http://www.neuro.uestc.edu.cn/rest/Down.html, and the detailed information including publications, comments and documents on REST can also be found from this website. An example of usage is given with comparative results of REST and average reference. We hope these user-friendly REST toolboxes could make the relatively novel technique of REST easier to study, especially for applications in various EEG studies.

  14. Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure. 1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions. 1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution. 1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest. 1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this s...

  15. Standard Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers an experimental procedure for checking experimental technique and instrumentation. If followed, this test method will provide repeatable potentiostatic and potentiodynamic anodic polarization measurements that will reproduce data determined by others at other times and in other laboratories provided all laboratories are testing reference samples from the same lot of Type 430 stainless steel. 1.2 Values stated in SI units are to be regarded as the standard. Inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Thermal Expansion and Density Data of UO2 and Simulated Fuel for Standard Reference

    International Nuclear Information System (INIS)

    Yang, Jae Hwan; Na, S. H.; Lee, J. W.; Kang, K. H.

    2010-01-01

    Standard Reference Data (SRD) is the scientific, technical data whose reliability and accuracy are evaluated by scientist group. Since SRD has a great impact on the improvement of national competitiveness by stirring up technological innovation in every sector of industries, many countries are making great efforts on establishing SRD in various areas. Data center for nuclear fuel material in Korea Atomic Energy Research Institute plays a role to providing property data of nuclear fuel material at high temperature, pressure, and radiation which are essential for the safety evaluation of nuclear power. In this study, standardization of data on thermal expansion and density of UO 2 were carried out in the temperature range from 300 K to 3100 K via uncertainty evaluation of indirectly produced data. Besides, standardization of data on thermal expansion and density of simulated fuel were also done in the temperature range from 350 K to 1750 K via uncertainty evaluation of directly produced data

  17. Calibrating NIST SRM 683 as A New International Reference Standard for Zn Isotopes

    Science.gov (United States)

    Yang, Y.; Zhang, X.; Yu, H.; Huang, F.

    2017-12-01

    Zinc isotopes have been widely applied in the cosmochemical, geochemical, and environmental studies (Moynier et al. 2017). Obtaining precise Zn isotopic data for inter-laboratory comparison is a prerequisite to these applications. Currently, the JMC3-0749L is the primary reference standard for Zn isotopes (Albarède 2004), but it is not commercially available now. Thus, it is necessary to calibrate a new international primary reference standard for Zn isotopic analysis. Chen et al. (2016) showed that NIST SRM 683 (a pure Zn metal nugget of 140 grams) has a δ66ZnJMC of 0.12‰, which is falling within the range of natural Zn isotopic compositions, and it may a good candidate for the next generation of international reference standard (Chen et al. 2016). In order to further examine whether NIST SRM 683 has a homogeneous Zn isotopic composition, we measured more NIST SRM 683 by double-spike methods using MC-ICPMS (Conway et al. 2013). The metal nuggets of NIST SRM 683 were intensively sampled by micro-drilling. Zinc isotope analyses for two nuggets show that they have δ66Zn of 0.14 ± 0.02‰ (2SD, N = 32) and 0.13 ± 0.02‰ (2SD, N = 33), respectively. These values are similar to those of two Zn metal nuggets (0.11 ± 0.02‰ vs. 0.12 ± 0.02‰) reported previously by Chen et al. (2016). We fully dissolved one nugget, producing pure Zn solution with identical Zn isotopic composition with the drilling samples. All results strongly support that NIST SRM 683 is homogeneous in Zn isotopic compositions which could be an ideal candidate for the next reference for Zn isotopes. Tests on more metal nuggets will be performed in a few months for further confirming the Zn isotope compositions and homogeneity. Reference: Albarède et al., 2004. 'The stable isotope geochemistry of copper and zinc', Reviews in Mineralogy and Geochemistry, 55: 409-27. Chen et al., 2016. 'Zinc Isotopic Compositions of NIST SRM 683 and Whole-Rock Reference Materials', Geostandards and

  18. 13 CFR 105.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... ethical conduct standards and financial disclosure regulations. 105.101 Section 105.101 Business Credit... RESPONSIBILITIES Standards of Conduct § 105.101 Cross-reference to employee ethical conduct standards and financial... to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635 and the...

  19. 18 CFR 3c.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... employee ethical conduct standards and financial disclosure regulations. 3c.1 Section 3c.1 Conservation of... STANDARDS OF CONDUCT § 3c.1 Cross-reference to employee ethical conduct standards and financial disclosure... branch-wide financial disclosure regulations at 5 CFR part 2634, the Standards of Ethical Conduct for...

  20. Standard Specification for Physical Characteristics of Nonconcentrator Terrestrial Photovoltaic Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This specification describes the physical requirements for primary and secondary terrestrial nonconcentrator photovoltaic reference cells. A reference cell is defined as a device that meets the requirements of this specification and is calibrated in accordance with Test Method E1125 or Test Method E1362. 1.2 Reference cells are used in the determination of the electrical performance of photovoltaic devices, as stated in Test Methods E948 and E1036. 1.3 Two reference cell physical specifications are described: 1.3.1 Small-Cell Package Design—A small, durable package with a low thermal mass, wide optical field-of-view, and standardized dimensions intended for photovoltaic devices up to 20 by 20 mm, and 1.3.2 Module-Package Design—A package intended to simulate the optical and thermal properties of a photovoltaic module design, but electric connections are made to only one photovoltaic cell in order to eliminate problems with calibrating series and parallel connections of cells. Physical dimensions ...

  1. Austenitic chromium nickel steel as standard reference material in measurement of thermal and temperature conductivity

    International Nuclear Information System (INIS)

    Binkele, L.

    1990-01-01

    A niobium-stabilized CrNi steel with the NBS designation SRM 735 is introduced as WLF standard reference material in a report by Hust and Giarratano, for the temperature range 300-1200 K and for thermal conductivities around 20 W/mk. However, its specification does not show it to be a direct member of the DIN family of CrNi steels. This report should be regarded as a continuation and supplement to the above-mentioned efforts in America. On the one hand, a solution of a possibly too-narrow specification is aimed at for the reference material, where it is important how sensitive the thermal conductivity is to changes in the chemical composition and changes of the manufacturing parameters and what accuracy can be reached for the reference values with the best measurement techniques. On the other hand, the data base should be expanded and the accuracy of the reference curve should be improved if possible. (orig./MM) [de

  2. Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standards.

    Science.gov (United States)

    Halvorsen, Ken; Agris, Paul F

    2014-11-15

    Measuring interactions between biological molecules is vitally important to both basic and applied research as well as development of pharmaceuticals. Although a wide and growing range of techniques is available to measure various kinetic and thermodynamic properties of interacting biomolecules, it can be difficult to compare data across techniques of different laboratories and personnel or even across different instruments using the same technique. Here we evaluate relevant biological interactions based on complementary DNA and RNA oligonucleotides that could be used as reference standards for many experimental systems. We measured thermodynamics of duplex formation using isothermal titration calorimetry, differential scanning calorimetry, and ultraviolet-visible (UV-vis) monitored denaturation/renaturation. These standards can be used to validate results, compare data from disparate techniques, act as a teaching tool for laboratory classes, or potentially to calibrate instruments. The RNA and DNA standards have many attractive features, including low cost, high purity, easily measurable concentrations, and minimal handling concerns, making them ideal for use as a reference material. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

    Directory of Open Access Journals (Sweden)

    Azmil Haizam Ahmad Tarmizi

    2008-01-01

    Full Text Available This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 ° C in palm oil, 22.7 ± 0.4 ° C in palm olein and 53.4 ± 0.2 ° C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of -20 ° C, 0 ° C, 6 ° C and 24 ° C upon storage for one year.

  4. Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards.

    Science.gov (United States)

    Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric

    2008-09-01

    Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.

  5. Function of microRNAs in the Osteogenic Differentiation and Therapeutic Application of Adipose-Derived Stem Cells (ASCs

    Directory of Open Access Journals (Sweden)

    Walter M. Hodges

    2017-12-01

    Full Text Available Traumatic wounds with segmental bone defects represent substantial reconstructive challenges. Autologous bone grafting is considered the gold standard for surgical treatment in many cases, but donor site morbidity and associated post-operative complications remain a concern. Advances in regenerative techniques utilizing mesenchymal stem cell populations from bone and adipose tissue have opened the door to improving bone repair in the limbs, spine, and craniofacial skeleton. The widespread availability, ease of extraction, and lack of immunogenicity have made adipose-derived stem cells (ASCs particularly attractive as a stem cell source for regenerative strategies. Recently it has been shown that small, non-coding miRNAs are involved in the osteogenic differentiation of ASCs. Specifically, microRNAs such as miR-17, miR-23a, and miR-31 are expressed during the osteogenic differentiation of ASCs, and appear to play a role in inhibiting various steps in bone morphogenetic protein-2 (BMP2 mediated osteogenesis. Importantly, a number of microRNAs including miR-17 and miR-31 that act to attenuate the osteogenic differentiation of ASCs are themselves stimulated by transforming growth factor β-1 (TGFβ-1. In addition, transforming growth factor β-1 is also known to suppress the expression of microRNAs involved in myogenic differentiation. These data suggest that preconditioning strategies to reduce TGFβ-1 activity in ASCs may improve the therapeutic potential of ASCs for musculoskeletal application. Moreover, these findings support the isolation of ASCs from subcutaneous fat depots that tend to have low endogenous levels of TGFβ-1 expression.

  6. Platinum stable isotope analysis of geological standard reference materials by double-spike MC-ICPMS.

    Science.gov (United States)

    Creech, J B; Baker, J A; Handler, M R; Bizzarro, M

    2014-01-10

    We report a method for the chemical purification of Pt from geological materials by ion-exchange chromatography for subsequent Pt stable isotope analysis by multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) using a 196 Pt- 198 Pt double-spike to correct for instrumental mass bias. Double-spiking of samples was carried out prior to digestion and chemical separation to correct for any mass-dependent fractionation that may occur due to incomplete recovery of Pt. Samples were digested using a NiS fire assay method, which pre-concentrates Pt into a metallic bead that is readily dissolved in acid in preparation for anion-exchange chemistry. Pt was recovered from anion-exchange resin in concentrated HNO 3 acid after elution of matrix elements, including the other platinum group elements (PGE), in dilute HCl and HNO 3 acids. The separation method has been calibrated using a precious metal standard solution doped with a range of synthetic matrices and results in Pt yields of ≥90% with purity of ≥95%. Using this chemical separation technique, we have separated Pt from 11 international geological standard reference materials comprising of PGE ores, mantle rocks, igneous rocks and one sample from the Cretaceous-Paleogene boundary layer. Pt concentrations in these samples range from ca. 5 ng g -1 to 4 μg g -1 . This analytical method has been shown to have an external reproducibility on δ 198 Pt (permil difference in the 198 Pt/ 194 Pt ratio from the IRMM-010 standard) of ±0.040 (2 sd) on Pt solution standards (Creech et al., 2013, J. Anal. At. Spectrom. 28, 853-865). The reproducibility in natural samples is evaluated by processing multiple replicates of four standard reference materials, and is conservatively taken to be ca. ±0.088 (2 sd). Pt stable isotope data for the full set of reference materials have a range of δ 198 Pt values with offsets of up to 0.4‰ from the IRMM-010 standard, which are readily resolved with this technique. These

  7. Bias in the absorption coefficient determination of a fluorescent dye, standard reference material 1932 fluorescein solution

    International Nuclear Information System (INIS)

    DeRose, Paul C.; Kramer, Gary W.

    2005-01-01

    The absorption coefficient of standard reference material[registered] (SRM[registered]) 1932, fluorescein in a borate buffer solution (pH=9.5) has been determined at λ=488.0, 490.0, 490.5 and 491.0 nm using the US national reference UV/visible spectrophotometer. The purity of the fluorescein was determined to be 97.6% as part of the certification of SRM 1932. The solution measured was prepared gravimetrically by diluting SRM 1932 with additional borate buffer. The value of the absorption coefficient was corrected for bias due to fluorescence that reaches the detector and for dye purity. Bias due to fluorescence was found to be on the order of -1% for both monochromatic and polychromatic (e.g., diode-array based) spectrophotometers

  8. Age and gender leucocytes variances and references values generated using the standardized ONE-Study protocol

    DEFF Research Database (Denmark)

    Kverneland, Anders H.; Streitz, Mathias; Geissler, Edward

    2016-01-01

    blood flow cytometry. The performance of our protocols was challenged here by profiling samples from healthy volunteers to reveal age- and gender-dependent differences and to establish a standardized reference cohort for use in clinical trials. Whole blood samples from two different cohorts were...... analyzed (first cohort: n = 52, second cohort: n = 46, both 20–84 years with equal gender distribution). The second cohort was run as a validation cohort by a different operator. The “ONE Study” panels were applied to analyze expression of >30 different surface markers to enumerate proportional...... cohort. Thus, we have proven the utility of our strategy and generated reproducible reference ranges accounting for age- and gender-dependent differences, which are crucial for a better patient monitoring and individualized therapy....

  9. Standard reference material certification: contribution of NAA with a TRIGA reactor

    International Nuclear Information System (INIS)

    Orvini, E.; Speziali, M.; Salvini, A.; Herborg, C.

    2002-01-01

    Pavia has cooperative links with the major international agencies devoted to the certification of SRMs or CRMs as the Bureau Communautaire de Reference (BCR), the European Institute for Reference Materials and Measurement (IRMM), the USA National Institute of Standards and Technology (NIST) and the International Atomic Energy Agency (IAEA). During these cooperative works, a large amount of analytical data obtained with NAA has been compared, and meaningful methodological information achieved with respect to accuracy and precision in the analysis of several elements at different concentrations in various matrices. Analytical data on As, Cd, Cr, Co, Cu, Cs, Fe, Zn, K, Sc, U, Th, Al, Sb, Mn, V, Hg, Sr, Rb, Se,Pt, all the Rare Earths and halogens Br, Cl, I, have been obtained and contributed for the final certification

  10. Characterization of standard reference material 2944, Bi-ion-doped glass, spectral correction standard for red fluorescence

    International Nuclear Information System (INIS)

    DeRose, Paul C.; Smith, Melody V.; Anderson, Jeffrey R.; Kramer, Gary W.

    2013-01-01

    Standard Reference Material (SRM) 2944 is a cuvette-shaped, Bi-ion-doped glass, recommended for optimal use for relative spectral correction of emission from 590 nm to 805 nm and day-to-day performance verification of steady-state fluorescence spectrometers. Properties of this standard that influence its effective use or contribute to the uncertainty in its certified emission spectrum were explored here. These properties include its photostability, absorbance, dissolution rate in water, anisotropy and temperature coefficient of fluorescence intensity. The expanded uncertainties (k=2) in the certified spectrum are about 4% around the nominal peak maximum at 704 nm and increase to about 6% at the wings, using an excitation wavelength of 515 nm. -- Highlights: ► The fluorescence emission spectrum of SRM 2944 was determined for spectral correction. ► This Bi-ion-doped glass has been certified in the fluorescence region from 530 nm to 830 nm. ► Fluorescence properties of the glass were determined, e.g., anisotropy, lifetime. ► SRM 2944 is photostable under common visible lamp excitation, when UV light is not present

  11. 29 CFR 2703.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards and...-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees... of Ethical Conduct at 5 CFR part 2635; the Commission's regulations at 5 CFR part 8401, which...

  12. 12 CFR 264.101 - Cross-reference to employees' ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Cross-reference to employees' ethical conduct... § 264.101 Cross-reference to employees' ethical conduct standards and financial disclosure regulations... branch-wide standards of ethical conduct at 5 CFR part 2635 and the Board's regulation at 5 CFR part 6801...

  13. 12 CFR 336.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Cross-reference to employee ethical conduct... and Conduct § 336.1 Cross-reference to employee ethical conduct standards and financial disclosure... Branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Corporation regulation at 5 CFR part...

  14. 45 CFR 1105.1 - Cross-reference to employee ethical conduct standards and financial disclosure and financial...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Cross-reference to employee ethical conduct... STANDARDS OF CONDUCT FOR EMPLOYEES § 1105.1 Cross-reference to employee ethical conduct standards and... ethical conduct at 5 CFR part 2635; the executive branch employees responsibilities and conduct...

  15. 49 CFR 99.735-1 - Cross-reference to ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Cross-reference to ethical conduct standards and... Transportation EMPLOYEE RESPONSIBILITIES AND CONDUCT General § 99.735-1 Cross-reference to ethical conduct... the executive branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Department of...

  16. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct standards... ENERGY (GENERAL PROVISIONS) CONDUCT OF EMPLOYEES § 1010.102 Cross-references to employee ethical conduct... Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635, the DOE regulation at...

  17. 22 CFR 705.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-reference to employee ethical conduct... INVESTMENT CORPORATION ADMINISTRATIVE PROVISIONS EMPLOYEE ETHICAL CONDUCT STANDARDS AND FINANCIAL DISCLOSURE REGULATIONS § 705.101 Cross-reference to employee ethical conduct standards and financial disclosure...

  18. 39 CFR 3000.735-101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct... employee ethical conduct standards and financial disclosure regulations. Employees of the Postal Regulatory Commission (Commission) are subject and should refer to the executive branch-wide Standards of Ethical...

  19. 5 CFR 1300.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Cross-reference to employees ethical conduct standards and financial disclosure regulations. 1300.1 Section 1300.1 Administrative Personnel OFFICE OF MANAGEMENT AND BUDGET ADMINISTRATIVE PROCEDURES STANDARDS OF CONDUCT § 1300.1 Cross-reference...

  20. 16 CFR 1030.101 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... PRODUCT SAFETY COMMISSION GENERAL EMPLOYEE STANDARDS OF CONDUCT General § 1030.101 Cross-references to employee ethical conduct standards and financial disclosure regulations. Employees of the Consumer Product... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct...

  1. Development of saw palmetto (Serenoa repens) fruit and extract standard reference materials.

    Science.gov (United States)

    Schantz, Michele M; Bedner, Mary; Long, Stephen E; Molloy, John L; Murphy, Karen E; Porter, Barbara J; Putzbach, Karsten; Rimmer, Catherine A; Sander, Lane C; Sharpless, Katherine E; Thomas, Jeanice B; Wise, Stephen A; Wood, Laura J; Yen, James H; Yarita, Takashi; NguyenPho, Agnes; Sorenson, Wendy R; Betz, Joseph M

    2008-10-01

    As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.

  2. The stability of uranium microspheres for future application as reference standard in analytical measurements

    Energy Technology Data Exchange (ETDEWEB)

    Middendorp, R.; Duerr, M.; Bosbach, D. [Forschungszentrum Juelich GmbH, IEK-6, 52428 Juelich (Germany)

    2016-07-01

    The monitoring of fuel-cycle facilities provides a tool to confirm the compliant operation, for example with respect to emissions into the environment or to supervise non-proliferation commitments. Hereby, anomalous situations can be detected in a timely manner and responsive action can be initiated to prevent an escalation into an event of severe consequence to society. In order to verify non-nuclear weapon states' compliance with the non-proliferation treaty (NPT), international authorities such as the International Atomic Energy Agency (IAEA) conduct inspections at facilities dealing with fissile or fertile nuclear materials. One measure consists of collection of swipe samples through inspectors for later analysis of collected nuclear material traces in the laboratory. Highly sensitive mass spectrometric methods provide a means to detect traces from nuclear material handling activities that provide indication of undeclared use of the facility. There are, however, no relevant (certified) reference materials available that can be used as calibration or quality control standards. Therefore, an aerosol-generation based process was established at Forschungszentrum Juelich for the production of spherical, mono-disperse uranium oxide micro-particles with accurately characterized isotopic compositions and amounts of uranium in the pico-gram range. The synthesized particles are studied with respect to their suitability as (certified) reference material in ultra-trace analysis. Several options for preparation and stabilization of the particles are available, where preparation of particles in suspension offers the possibility to produces specific particle mixtures. In order to assess the stability of particles, dissolution behavior and isotope exchange effects of particles in liquid suspension is studied on the bulk of suspended particles and also via micro-analytical methods applied for single particle characterization. The insights gained within these studies will

  3. 22 CFR 1001.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-references to employee ethical conduct... FOUNDATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1001.1 Cross-references to employee ethical conduct... Foundation should refer to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR...

  4. SITE SPECIFIC REFERENCE PERSON PARAMETERS AND DERIVED CONCENTRATION STANDARDS FOR THE SAVANNAH RIVER SITE

    Energy Technology Data Exchange (ETDEWEB)

    Jannik, T.

    2013-03-14

    The purpose of this report is twofold. The first is to develop a set of behavioral parameters for a reference person specific for the Savannah River Site (SRS) such that the parameters can be used to determine dose to members of the public in compliance with Department of Energy (DOE) Order 458.1 “Radiation Protection of the Public and the Environment.” A reference person is a hypothetical, gender and age aggregation of human physical and physiological characteristics arrived at by international consensus for the purpose of standardizing radiation dose calculations. DOE O 458.1 states that compliance with the annual dose limit of 100 mrem (1 mSv) to a member of the public may be demonstrated by calculating the dose to the maximally exposed individual (MEI) or to a representative person. Historically, for dose compliance, SRS has used the MEI concept, which uses adult dose coefficients and adult male usage parameters. Beginning with the 2012 annual site environmental report, SRS will be using the representative person concept for dose compliance. The dose to a representative person will be based on 1) the SRS-specific reference person usage parameters at the 95th percentile of appropriate national or regional data, which are documented in this report, 2) the reference person (gender and age averaged) ingestion and inhalation dose coefficients provided in DOE Derived Concentration Technical Standard (DOE-STD-1196-2011), and 3) the external dose coefficients provided in the DC_PAK3 toolbox. The second purpose of this report is to develop SRS-specific derived concentration standards (DCSs) for all applicable food ingestion pathways, ground shine, and water submersion. The DCS is the concentration of a particular radionuclide in water, in air, or on the ground that results in a member of the public receiving 100 mrem (1 mSv) effective dose following continuous exposure for one year. In DOE-STD-1196-2011, DCSs were developed for the ingestion of water, inhalation of

  5. ASC Addresses Unit Commanders' Concerns through LBE and Reset Programs

    National Research Council Canada - National Science Library

    Young, Mark E

    2008-01-01

    .... Army Sustainment Command (ASC), part of the U.S. Army Materiel Command (AMC) team, is available to assist, identify, and resolve equipment and maintenance problems as well as materiel readiness issues for combatant commanders...

  6. USDA-ASCS 1936-1939 Air Photos

    Data.gov (United States)

    Minnesota Department of Natural Resources — This data set is a digital version of aerial photographs taken during the 1936-1939 time frame for the USDA-ASCS. These photos were originally recorded at a scale of...

  7. The American Satellite Company (ASC) satellite deployed from payload bay

    Science.gov (United States)

    1985-01-01

    The American Satellite Company (ASC) communications satellite is deployed from the payload bay of the Shuttle Discovery. A portion of the cloudy surface of the earth can be seen to the left of the frame.

  8. A Framework for Establishing Standard Reference Scale of Texture by Multivariate Statistical Analysis Based on Instrumental Measurement and Sensory Evaluation.

    Science.gov (United States)

    Zhi, Ruicong; Zhao, Lei; Xie, Nan; Wang, Houyin; Shi, Bolin; Shi, Jingye

    2016-01-13

    A framework of establishing standard reference scale (texture) is proposed by multivariate statistical analysis according to instrumental measurement and sensory evaluation. Multivariate statistical analysis is conducted to rapidly select typical reference samples with characteristics of universality, representativeness, stability, substitutability, and traceability. The reasonableness of the framework method is verified by establishing standard reference scale of texture attribute (hardness) with Chinese well-known food. More than 100 food products in 16 categories were tested using instrumental measurement (TPA test), and the result was analyzed with clustering analysis, principal component analysis, relative standard deviation, and analysis of variance. As a result, nine kinds of foods were determined to construct the hardness standard reference scale. The results indicate that the regression coefficient between the estimated sensory value and the instrumentally measured value is significant (R(2) = 0.9765), which fits well with Stevens's theory. The research provides reliable a theoretical basis and practical guide for quantitative standard reference scale establishment on food texture characteristics.

  9. Validation of IRDFF in 252Cf Standard and IRDF-2002 Reference Neutron Fields

    Directory of Open Access Journals (Sweden)

    Simakov Stanislav

    2016-01-01

    Full Text Available The results of validation of the latest release of International Reactor Dosimetry and Fusion File, IRDFF-1.03, in the standard 252Cf(s.f. and reference 235U(nth,f neutron benchmark fields are presented. The spectrum-averaged cross sections were shown to confirm IRDFF-1.03 in the 252Cf standard spontaneous fission spectrum; that was not the case for the current recommended spectra for 235U(nth,f. IRDFF was also validated in the spectra of the research reactor facilities ISNF, Sigma-Sigma and YAYOI, which are available in the IRDF-2002 collection. The ISNF facility was re-simulated to remove unphysical oscillations in the spectrum. IRDFF-1.03 was shown to reproduce reasonably well the spectrum-averaged data measured in these fields except for the case of YAYOI.

  10. IAEA nuclear data for applications: Cross section standards and the reference input parameter library (RIPL)

    International Nuclear Information System (INIS)

    Capote Noy, Roberto; Nichols, Alan L.; Pronyaev, Vladimir G.

    2003-01-01

    An integral part of the activities of the IAEA Nuclear Data Section involves the development of nuclear data for a wide range of user applications. When considering low-energy nuclear reactions induced by neutrons, photons and charged particles, a detailed knowledge is required of the production cross sections over a wide energy range, spectra of emitted particles and their angular distributions. Two highly relevant IAEA data development projects are considered in this paper. Neutron reaction cross-section standards represent the basic quantities needed in nuclear reaction cross-section measurements and evaluations. These standards and the covariance matrices of their uncertainties were previously evaluated and released in 1987. However, the derived uncertainties were subsequently considered to be unrealistic low due to the effect of the low uncertainties obtained in fitting the light element standards to the R-matrix model; as a result, evaluators were forced to scale up the uncertainties to 'expected values'. An IAEA Coordinated Research Project (CRP) entitled 'Improvement of the Standard Cross Sections for Light Elements' was initiated in 2002 to improve the evaluation methodology for the covariance matrix of uncertainty in the R-matrix model fits, and to produce R-matrix evaluations of the important light element standards. The scope of this CRP has been substantially extended to include the preparation of a full set of evaluated standard reactions and covariance matrices of their uncertainties. While almost all requests for nuclear data were originally addressed through measurement programmes, our theoretical understanding of nuclear phenomena has reached a reasonable degree of reliability and nuclear modeling has become standard practice in nuclear data evaluations (with measurements remaining crucial for data testing and benchmarking). Since nuclear model codes require a considerable amount of numerical input, the IAEA has instigated extensive efforts to

  11. Quantitative micro x-ray fluorescence analyses without reference standard material; Referenzprobenfreie quantitative Mikro-Roentgenfluoreszenzanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, Timo

    2009-07-15

    X-ray fluorescence analysis (XRF) is a standard method for non-destructive investigations. Due to the development of polycapillary optics and SDDdetectors requiring no cooling with liquid nitrogen, XRF becomes a suitable method for a large number of applications, e. g. for the analysis of objects in arts and archaeology. Spectrometers developed for those purposes allow investigations outside of laboratories und provide excitation areas with diameters of 10-70 {mu}m. In most applications, quantification of XRF data is realized by the usage of standard reference materials. Due to absorption processes in the samples the accuracy of the results depends strongly on the similarity of the sample and the reference standard. In cases where no suitable references are available, quantification can be done based on the ''fundamental parameter (fp) method''. This quantification procedure is based on a set of equations describing the fluorescence production and detection mathematical. The cross sections for the interaction of x-rays with matter can be taken from different databases. During an iteration process the element concentrations can be determined. Quantitative XRF based on fundamental parameters requires an accurate knowledge of the excitation spectrum. In case of a conventional setup this spectrum is given by the X-ray tube spectrum and can be calculated. The use of polycapillary optics in micro-XRF spectrometers changes the spectral distribution of the excitation radiation. For this reason it is necessary to access the transmission function of the used optic. The aim of this work is to find a procedure to describe this function for routine quantification based on fundamental parameters. Most of the measurements have been carried out using a commercial spectrometer developed for applications in arts and archaeology. On the one hand the parameters of the lens, used in the spectrometer, have been investigated by different experimental characterization

  12. Catalog of NBS standard reference materials, 1975--76 edition. Special pub

    International Nuclear Information System (INIS)

    Seward, R.W.

    1975-06-01

    This Catalog lists and describes the Standard Reference Materials (SRM's), Research Materials (RM's), and General Materials (GM's) currently distributed by the National Bureau of Standards, as well as many of the materials currently in preparation. SRM's are used to calibrate measurement systems and to provide a central basis for uniformity and accuracy of measurement. The unit and quantity, the type, and the certified characterization are listed for each SRM, as well as directions for ordering. The RM's are not certified, but are issued to meet the needs of scientists engaged in materials research. RM's are issued with a 'Report of Investigation', the sole authority of which is the author of the report. The GM's are standardized by some agency other than NBS. NBS acts only as a distribution point and does not participate in the standardization of these materials. Announcements of new and renewal SRM's, RM's and GM's are made in the semi-annual supplements of this Catalog, SRM Price List, and in scientific and trade journals

  13. Standardization of reference radiation field of beta for 85Kr using extrapolation chamber

    International Nuclear Information System (INIS)

    Nazaroh; Fendinugroho

    2013-01-01

    Standardization of reference radiation field of beta for 85 Kr in PTKMR-BATAN Laboratory has been performed at the SDD's 30 cm by using extrapolation chamber detector, coupled with Uni dose electrometer. The result was : (8.98±3 %) mGy/h, at 95 % confidence level. The aim of standardization of reference radiation field is to support radiation protection and safety program, provided by the International Atomic Energy Agency to its Member States, included BATAN-Indonesia, especially, PTKMR. The aim of radiation protection program and safety program is to promote an internationally harmonized approach for radiation measurement in protection level, besides for calibration of radiation measuring instrument, which users spread across Indonesia, with the number of about 795 firms in the year of 2012. These benefits can be felt by workers, communities and the environment, because by calibration, measurement survey meter, pocket dosimeter and TLD to be more accurate so that the radiation dose received by radiation workers is accurate and can be ascertained in a specified period, not to exceed a predetermined NBD by BAPETEN. The aim of this calibration is appropriate with the primary objective of calibration on IAEA/TRS16:2000. (author)

  14. The Astrobiology in Secondary Classrooms (ASC) curriculum: focusing upon diverse students and teachers.

    Science.gov (United States)

    Arino de la Rubia, Leigh S

    2012-09-01

    The Minority Institution Astrobiology Collaborative (MIAC) began working with the NASA Goddard Center for Astrobiology in 2003 to develop curriculum materials for high school chemistry and Earth science classes based on astrobiology concepts. The Astrobiology in Secondary Classrooms (ASC) modules emphasize interdisciplinary connections in astronomy, biology, chemistry, geoscience, physics, mathematics, and ethics through hands-on activities that address national educational standards. Field-testing of the Astrobiology in Secondary Classrooms materials occurred over three years in eight U.S. locations, each with populations that are underrepresented in the career fields of science, technology, engineering, and mathematics. Analysis of the educational research upon the high school students participating in the ASC project showed statistically significant increases in students' perceived knowledge and science reasoning. The curriculum is in its final stages, preparing for review to become a NASA educational product.

  15. Validity Study of a Jump Mat Compared to the Reference Standard Force Plate.

    Science.gov (United States)

    Rogan, Slavko; Radlinger, Lorenz; Imhasly, Caroline; Kneubuehler, Andrea; Hilfiker, Roger

    2015-12-01

    In the field of vertical jump diagnostics, force plates (FP) are the reference standard. Recently, despite a lack of evidence, jump mats have been used increasingly. Important factors in favor of jumping mats are their low cost and portability. This validity study compared the Haynl-Elektronik jump mat (HE jump mat) with the reference standard force plate. Ten healthy volunteers participated and each participant completed three series of five drop jumps (DJ). The parameters ground contact time (GCT) and vertical jump height (VJH) from the HE jump mat and the FP were used to evaluate the concurrent validity. The following statistical calculations were performed: Pearson's correlation (r), Bland-Altman plots (standard and for adjusted trend), and regression equations. The Bland-Altman plots suggest that the HE jump mat measures shorter contact times and higher jump heights than the FP. The trend-adjusted Bland-Altman plot shows higher mean differences and wider wing-spreads of confidence limits during longer GCT. During the VJH the mean differences and the wing-spreads of the confidence limits throughout the range present as relatively constant. The following regression equations were created, as close as possible to the true value: GCT = 5.920385 + 1.072293 × [value HE jump mat] and VJH = -1.73777 + 1.011156 × [value HE jump mat]. The HE jump mat can be recommended in relation to the validity of constraints. In this study, only a part of the quality criteria were examined. For the final recommendation it is advised to examine the HE jump mat on the other quality criteria (test-retest reliability, sensitivity change).

  16. Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

    Directory of Open Access Journals (Sweden)

    Azmil Haizam Ahmad Tarmizi

    2008-01-01

    Full Text Available This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of –20 °C, 0 °C, 6 °C and 24 °C upon storage for one year.

  17. Sandia National Laboratories Advanced Simulation and Computing (ASC) software quality plan : ASC software quality engineering practices Version 3.0.

    Energy Technology Data Exchange (ETDEWEB)

    Turgeon, Jennifer L.; Minana, Molly A.; Hackney, Patricia; Pilch, Martin M.

    2009-01-01

    The purpose of the Sandia National Laboratories (SNL) Advanced Simulation and Computing (ASC) Software Quality Plan is to clearly identify the practices that are the basis for continually improving the quality of ASC software products. Quality is defined in the US Department of Energy/National Nuclear Security Agency (DOE/NNSA) Quality Criteria, Revision 10 (QC-1) as 'conformance to customer requirements and expectations'. This quality plan defines the SNL ASC Program software quality engineering (SQE) practices and provides a mapping of these practices to the SNL Corporate Process Requirement (CPR) 001.3.6; 'Corporate Software Engineering Excellence'. This plan also identifies ASC management's and the software project teams responsibilities in implementing the software quality practices and in assessing progress towards achieving their software quality goals. This SNL ASC Software Quality Plan establishes the signatories commitments to improving software products by applying cost-effective SQE practices. This plan enumerates the SQE practices that comprise the development of SNL ASC's software products and explains the project teams opportunities for tailoring and implementing the practices.

  18. 41 CFR 105-735.1 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Science.gov (United States)

    2010-07-01

    ... employee ethical conduct standards, financial disclosure regulations, and other regulations. 105-735.1... CONDUCT § 105-735.1 Cross-references to employee ethical conduct standards, financial disclosure... executive branch-wide standards of ethical conduct at 5 CFR part 2635, GSA's regulations at 5 CFR part 6701...

  19. 36 CFR 400.1 - Cross-references to employees' ethical conduct standards, financial disclosure regulations and...

    Science.gov (United States)

    2010-07-01

    ...' ethical conduct standards, financial disclosure regulations and other conduct rules. 400.1 Section 400.1... CONDUCT § 400.1 Cross-references to employees' ethical conduct standards, financial disclosure regulations... executive branch-wide standards of ethical conduct and financial disclosure regulations at 5 CFR parts 2634...

  20. 29 CFR 1600.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards and... to employee ethical conduct standards and financial disclosure regulations. Employees of the Equal Employment Opportunity Commission (EEOC) are subject to the executive branch-wide Standards of Ethical...

  1. 36 CFR 811.1 - Cross-references to employees' ethical conduct standards, financial disclosure and financial...

    Science.gov (United States)

    2010-07-01

    ...' ethical conduct standards, financial disclosure and financial interests regulations and other conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 811.1 Cross-references to employees' ethical conduct standards... Council on Historic Preservation are subject to the executive branch-wide standards of ethical conduct...

  2. 24 CFR 0.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... ethical conduct standards and financial disclosure regulations. 0.1 Section 0.1 Housing and Urban... Cross-reference to employees ethical conduct standards and financial disclosure regulations. Employees...-wide standards of ethical conduct at 5 CFR part 2635, the Department's regulation at 5 CFR part 7501...

  3. Atypical squamous cells, cannot exclude high grade squamous intraepithelial (ASC-H in HIV-positive women

    Directory of Open Access Journals (Sweden)

    Michelow Pam

    2010-01-01

    Full Text Available Objective: South Africa has very high rates of both HIV infection and cervical pathology. The management of ASC-H is colposcopy and directed biopsy, but with so many women diagnosed with HSIL and a dearth of colposcopy centres in South Africa, women with cytologic diagnosis of ASC-H may not be prioritized for colposcopy. The aim of this study was to determine if HIV-positive women with a cytologic diagnosis of ASC-H should undergo immediate colposcopy or whether colposcopy can be delayed, within the context of an underfunded health care setting with so many competing health needs. Materials and Methods: A computer database search was performed from the archives of an NGO-administered clinic that offers comprehensive HIV care. All women with a cytologic diagnosis of ASC-H on cervical smears from September 2005 until August 2009 were identified. Histologic follow up was sought in all patients. Results: A total of 2111 cervical smears were performed and 41 diagnosed as ASC-H (1.94%. No histologic follow up data was available in 15 cases. Follow up histologic results were as follows: three negative (11.5%, five koilocytosis and/ or CIN1 (19.2%, ten CIN2 (38.5% and eight CIN3 (30.8%. There were no cases of invasive carcinoma on follow up. Conclusion: The current appropriate management of HIV-positive women in low-resource settings with a diagnosis of ASC-H on cervical smear is colposcopy, despite the costs involved. In the future and if cost-effective in developing nations, use of novel markers may help select which HIV-positive women can be managed conservatively and which ones referred for more active treatment. More research in this regard is warranted.

  4. Standard Test Method for Calibration of Non-Concentrator Photovoltaic Secondary Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers calibration and characterization of secondary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device. 1.2 Secondary reference cells are calibrated indoors using simulated sunlight or outdoors in natural sunlight by reference to a primary reference cell previously calibrated to the same desired reference spectral irradiance distribution. 1.3 Secondary reference cells calibrated according to this test method will have the same radiometric traceability as the of the primary reference cell used for the calibration. Therefore, if the primary reference cell is traceable to the World Radiometric Reference (WRR, see Test Method E816), the resulting secondary reference cell will also be traceable to the WRR. 1.4 This test method appli...

  5. Preparation and certification of trace mercury in water standard reference materials

    International Nuclear Information System (INIS)

    Moody, J.R.; Paulsen, P.J.; Rains, T.C.; Rook, H.L.

    1976-01-01

    The study of mercury in natural water supplies requires a Standard Reference Material (SRM) with a certified concentration at the 1 ng/g level. NBS SRM's have been prepared with nominal mercury concentrations of 1.5 μg/g and 1.2 ng/g. Confirmation of these values was obtained by neutron activation, atomic absorption, and isotope dilution-spark source mass spectrometry (IDSSMS). Nitric acid and trace amounts of gold were added to achieve a stable mercury concentration. The precautions observed for cleaning the glass and Teflon containers, preparation of mercury solutions, and the packaging of the SRM's are given. As an example of the care needed in the analysis of mercury at these levels, specific details are presented for the chemistry required to prepare samples for the spark source mass spectrometer

  6. Crystal structure of isopropyl 2-hydroxy-2-phenylacetate: a pharmacopoeia reference standard

    Directory of Open Access Journals (Sweden)

    Ivan Isaiev

    2017-05-01

    Full Text Available The title compound, C11H14O3, is used as a pharmacopoeia reference standard for determining impurities in the drug Pregabalin, used for the treatment of epilepsy and diabetic neuropathic pain. The molecule is far from being planar, with the dihedral angle between the planes of the aromatic ring and the carboxyl fragment (O—C=O being 76.1 (6°. The isopropyl substituent is located in a synperiplanar position relative to the C=O bond and is turned so that the C—O—C—H torsion angle is −43.7°. In the crystal, bifurcated O—H...(O,O hydrogen bonds, enclosing R12(5 ring motifs, lead to the formation of chains propagating along the c-axis direction. Inversion-related chains are linked by the C—H...O hydrogen bonds, forming undulating layers lying parallel to the bc plane.

  7. Establishing the traceability of a uranyl nitrate solution to a standard reference material

    International Nuclear Information System (INIS)

    Jackson, C.H.; Clark, J.P.

    1978-01-01

    A uranyl nitrate solution for use as a Working Calibration and Test Material (WCTM) was characterized, using a statistically designed procedure to document traceability to National Bureau of Standards Reference Material (SPM-960). A Reference Calibration and Test Material (PCTM) was prepared from SRM-960 uranium metal to approximate the acid and uranium concentration of the WCTM. This solution was used in the characterization procedure. Details of preparing, handling, and packaging these solutions are covered. Two outside laboratories, each having measurement expertise using a different analytical method, were selected to measure both solutions according to the procedure for characterizing the WCTM. Two different methods were also used for the in-house characterization work. All analytical results were tested for statistical agreement before the WCTM concentration and limit of error values were calculated. A concentration value was determined with a relative limit of error (RLE) of approximately 0.03% which was better than the target RLE of 0.08%. The use of this working material eliminates the expense of using SRMs to fulfill traceability requirements for uranium measurements on this type material. Several years' supply of uranyl nitrate solution with NBS traceability was produced. The cost of this material was less than 10% of an equal quantity of SRM-960 uranium metal

  8. Simultaneous Determination of Four Anthraquinones in Polygoni Multiflori Radix with Single Reference Standard by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Hua Yang

    2015-07-01

    Full Text Available Objective: To establish a rapid, accurate and reliable analytical method for the simultaneous determination of four major anthraquinones in Polygoni Multiflori Radix (PMR using single reference standard.

  9. The NIST natural-matrix radionuclide standard reference material program for ocean studies

    International Nuclear Information System (INIS)

    Inn, K.G.W.; Zhichao Lin; Zhongyu Wu; MacMahon, C.; Filliben, J.J.; Krey, P.; Feiner, M.; Harvey, J.

    2001-01-01

    In 1997, the Low-level Working Group of the International Committee on Radionuclide Metrology met in Boston, MA (USA) to define the characteristics of a new set of environmental radioactivity reference materials. These reference materials were to provide the radiochemist with the same analytical challenges faced when assaying environmental samples. It was decided that radionuclide bearing natural materials should be collected from sites where there had been sufficient time for natural processes to redistribute the various chemically different species of the radionuclides. Over the succeeding years, the National Institute of Standards and Technology (NIST), in cooperation with other highly experienced laboratories, certified and issued a number of these as low-level radioactivity Standard Reference Materials (SRMs) for fission and activation product and actinide concentrations. The experience of certifying these SRMs has given NIST the opportunity to compare radioanalytical methods and learn of their limitations. NIST convened an international workshop in 1994 to define the natural-matrix radionuclide SRM needs for ocean studies. The highest priorities proposed at the workshop were for sediment, shellfish, seaweed, fish flesh and water matrix SRMs certified for mBq per sample concentrations of 90 Sr, 137 Cs and 239 Pu + 240 Pu. The most recent low-level environmental radionuclide SRM issued by NIST, Ocean Sediment (SRM 4357) has certified and uncertified values for the following 22 radionuclides: 40 K, 90 Sr, 129 I, 137 Cs, 155 Eu, 210 Pb, 210 Po, 212 Pb, 214 Bi, 226 Ra, 228 Ra, 228 Th, 230 Th, 232 Th, 234 U, 235 U, 237 Np, 238 U, 238 Pu, 239 Pu + 240 Pu, and 241 Am. The uncertainties for a number of the certified radionuclides are non-symmetrical and relatively large because of the non-normal distribution of reported values. NIST is continuing its efforts to provide the ocean studies community with additional natural matrix radionuclide SRMs. The freeze

  10. The use of high accuracy NAA for the certification of NIST Standard Reference Materials

    International Nuclear Information System (INIS)

    Becker, D.A.; Greenberg, R.R.; Stone, S.

    1991-01-01

    Neutron activation analysis (NAA) is only one of many analytical techniques used at the National Institute of Standards and Technology (NIST) for the certification of NIST Standard Reference Materials (SRMs). We compete daily against all of the other available analytical techniques in terms of accuracy, precision, and the cost required to obtain that requisite accuracy and precision. Over the years, the authors have found that NAA can and does compete favorably with these other techniques because of its' unique capabilities for redundancy and quality assurance. Good examples are the two new NIST leaf SRMs, Apple Leaves (SRM 1515) and Peach Leaves (SRM 1547). INAA was used to measure the homogeneity of 12 elements in 15 samples of each material at the 100 mg sample size. In addition, instrumental and radiochemical NAA combined for 27 elemental determinations, out of a total of 54 elemental determinations made on each material with all NIST techniques combined. This paper describes the NIST NAA procedures used in these analyses, the quality assurance techniques employed, and the analytical results for the 24 elements determined by NAA in these new botanical SRMs. The NAA results are also compared to the final certified values for these SRMs

  11. Determination of 25 elements in biological standard reference materials by neutron activation analysis

    International Nuclear Information System (INIS)

    Guzzi, G.; Pietra, R.; Sabbioni, E.

    1974-12-01

    Standard and Certified Reference Materials programme of the JRC includes the determination of trace elements in complex biological samples delivered by the U.S. National Bureau of Standards: Bovine liver (NBS SRM 1577), Orchard Leaves (NBS SRM 1571) and Tomato Leaves. The study has been performed by the use of neutron activation analysis. Due to the very low concentration of some elements, radiochemical groups or elemental separation procedures were necessary. The paper describes the techniques used to analyse 25 elements. Computer assisted instrumental neutron activation analysis with high resolution Ge(Li) spectrometry was considerably advantageous in the determination of Na, K, Cl, Mn, Fe, Rb and Co and in some cases of Ca, Zn, Cs, Sc, and Cr. For low contents of Ca, Mg, Ni and Si special chemical separation schemes, followed by Cerenkov counting have been developped. Two other separation procedures allowing the determination of As, Cd, Ga, Hg, Mo, Cu, Sr Se, Ba and P have been set up. The first, the simplified one involves the use of high resolution Ge(Li) detectors, the second, the more complete one involves a larger number of shorter measurements performed by simpler and more sensitive techniques, such as NaI(Tl) scintillation spectrometry and Cerenkov counting. The results obtained are presented and discussed

  12. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    Science.gov (United States)

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  13. [Classification of Colombian children with malnutrition according to NCHS reference or WHO standard].

    Science.gov (United States)

    Velásquez, Claudia; Bermúdez, Juliana; Echeverri, Claudia; Estrada, Alejandro

    2011-12-01

    A descriptive study was conducted to evaluate the concordance of National Center for Health Statistics reference (NCHS) used to classify undernourished children from Colombia with the WHO Child Growth Standards. We used data from children aged 6 to 59 months with acute malnutrition (Z Infantil" nutrition program in Colombia. Indicators height-for-age, weight for-height were analyzed when they were admitted to the hospital and weight for-height leaving the hospital. A statistical method used to compare means was T-student. Correlation coefficient intraclass (CCI) and Kappa index evaluated the concordance between NCHS and OMS; McNemar method evaluated the changes on the nutritional classification for children according to growth devices used. Of the total number of children classified as normal by NCHS, 10.4% were classified as stunted by WHO. 64% of the children admitted to the hospital presented acute malnutrition according to NCHS, of these 44,8% presented severe emaciation according to OMS, indeed severe emaciation increased of 36,0% to 63,3% using OMS. 5% of children leaving the hospital could need to stay more days if they had been evaluated with OMS. Growth devices shown high concordance in height-for-age (CCI = 0,988; k= 0,866) and weight for-height (CCI = 0,901; k = 0,578). Concluded that OMS growth standards classified more malnourished children and more severe states, in addition more malnourished children could be hospitalized and they could stay more days.

  14. Implementation of Dietary Reference Intake Standards in Preschool Menus in Poland.

    Science.gov (United States)

    Myszkowska-Ryciak, Joanna; Harton, Anna

    2018-05-10

    Although the nutritional value of preschool menus largely determines the proper nutrition of attending children, their nutrient composition often does not meet the standards. The purpose of the study was to assess the nutritional value of menus served in preschools throughout Poland. We analyzed a sample of 10 daily menus and inventory reports reflecting foods and beverages served in 270 full-board government-sponsored preschools. Nutrient content was calculated per child per day, and compared with 70% of dietary reference intake (DRI) for children aged 1⁻3 and 4⁻6. The content of energy, protein, fat, and carbohydrates generally exceeded 70% of DRI. The amount of vitamins was correct, with the exception of vitamin D (100% of daycare centers (DCCs) were below the recommendations); in ≤3% of preschools vitamin E, folate, and niacin were below DRI. Calcium was too low in 63% of preschools for children aged 1⁻3 years and in 99% for 4⁻6-year-olds. A shortage of iodine, iron, and potassium (especially for 4⁻6-year-olds) was observed in a small number of preschools. Our study highlights the need for uniform legal standards of nutrition in childcare centers, based on the current recommendations for the age group.

  15. New birth weight reference standards customised to birth order and sex of babies from South India.

    Science.gov (United States)

    Kumar, Velusamy Saravana; Jeyaseelan, Lakshmanan; Sebastian, Tunny; Regi, Annie; Mathew, Jiji; Jose, Ruby

    2013-02-14

    The foetal growth standards for Indian children which are available today suffer due to methodological problems. These are, for example, not adhering to the WHO recommendation to base gestational age on the number of completed weeks and secondly, not excluding mothers with risk factors. This study has addressed both the above issues and in addition provides birthweight reference ranges with regard to sex of the baby and maternal parity. Data from the labour room register from 1996 to 2010 was obtained. A rotational sampling scheme was used i.e. the 12 months of the year were divided into 4 quadrants. All deliveries in January were considered to represent the first quadrant. Similarly all deliveries in April, July and October were considered to represent 2nd, 3rd and 4th quadrants. In each successive year different months were included in each quadrant. Only those mothers aged 20-39 years and delivered between 24 to 42 weeks gestational age were considered. Those mothers with obstetric risk factors were excluded. The reference standards were fitted using the Generalized Additive Models for Location Scale and Shape (GAMLSS) method for Box-Cox t distribution with cubic spline smoothing. There were 41,055 deliveries considered. When women with risk factors were excluded 19,501 deliveries could be included in the final analysis. The male babies of term firstborn were found to be 45 g heavier than female babies. The mean birthweights were 2934 g and 2889.5 g respectively. Similarly, among the preterm babies, the first born male babies weighed 152 g more than the female babies. The mean birthweights were 1996 g and 1844 g respectively.In the case of later born babies, the term male babies weighed 116 grams more than the females. The mean birth weights were 3085 grams and 2969 grams respectively. When considering later born preterm babies, the males outweighed the female babies by 111 grams. The mean birthweights were 2089 grams and 1978 grams

  16. New birth weight reference standards customised to birth order and sex of babies from South India

    Directory of Open Access Journals (Sweden)

    Kumar Velusamy Saravana

    2013-02-01

    Full Text Available Abstract Background The foetal growth standards for Indian children which are available today suffer due to methodological problems. These are, for example, not adhering to the WHO recommendation to base gestational age on the number of completed weeks and secondly, not excluding mothers with risk factors. This study has addressed both the above issues and in addition provides birthweight reference ranges with regard to sex of the baby and maternal parity. Methods Data from the labour room register from 1996 to 2010 was obtained. A rotational sampling scheme was used i.e. the 12 months of the year were divided into 4 quadrants. All deliveries in January were considered to represent the first quadrant. Similarly all deliveries in April, July and October were considered to represent 2nd, 3rd and 4th quadrants. In each successive year different months were included in each quadrant. Only those mothers aged 20–39 years and delivered between 24 to 42 weeks gestational age were considered. Those mothers with obstetric risk factors were excluded. The reference standards were fitted using the Generalized Additive Models for Location Scale and Shape (GAMLSS method for Box – Cox t distribution with cubic spline smoothing. Results There were 41,055 deliveries considered. When women with risk factors were excluded 19,501 deliveries could be included in the final analysis. The male babies of term firstborn were found to be 45 g heavier than female babies. The mean birthweights were 2934 g and 2889.5 g respectively. Similarly, among the preterm babies, the first born male babies weighed 152 g more than the female babies. The mean birthweights were 1996 g and 1844 g respectively. In the case of later born babies, the term male babies weighed 116grams more than the females. The mean birth weights were 3085 grams and 2969 grams respectively. When considering later born preterm babies, the males outweighed the female babies by 111 grams. The

  17. 12 CFR 1401.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct... INSURANCE CORPORATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1401.1 Cross-references to employee ethical... the Farm Credit System Insurance Corporation are subject to the Standards of Ethical Conduct for...

  18. 22 CFR 1504.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-references to employee ethical conduct... FOUNDATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1504.1 Cross-references to employee ethical conduct... Foundation are subject to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR...

  19. 22 CFR 1100.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-references to employee ethical conduct... STATES SECTION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1100.1 Cross-references to employee ethical... executive branch standards of ethical conduct contained in 5 CFR part 2635, the executive branch financial...

  20. 12 CFR 400.101 - Cross-reference to employee financial disclosure and ethical conduct standards regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Cross-reference to employee financial disclosure and ethical conduct standards regulations. 400.101 Section 400.101 Banks and Banking EXPORT-IMPORT.... Employees of the Export-Import Bank of the United States (Bank) should refer to: (a) The executive branch...

  1. New reference charts for testicular volume in Dutch children and adolescents allow the calculation of standard deviation scores

    NARCIS (Netherlands)

    Joustra, S.D.; Plas, E.M. van der; Goede, J.; Oostdijk, W.; Delemarre-van de Waal, H.A.; Hack, W.W.M.; Buuren, S. van; Wit, J.M.

    2015-01-01

    Aim Accurate calculations of testicular volume standard deviation (SD) scores are not currently available. We constructed LMS-smoothed age-reference charts for testicular volume in healthy boys. Methods The LMS method was used to calculate reference data, based on testicular volumes from

  2. 45 CFR 706.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Cross-references to employee ethical conduct... 706.1 Public Welfare Regulations Relating to Public Welfare (Continued) COMMISSION ON CIVIL RIGHTS EMPLOYEE RESPONSIBILITIES AND CONDUCT § 706.1 Cross-references to employee ethical conduct standards...

  3. 77 FR 202 - Federal Acquisition Regulation; Updated Financial Accounting Standards Board Accounting References

    Science.gov (United States)

    2012-01-03

    ... 9000-AM00 Federal Acquisition Regulation; Updated Financial Accounting Standards Board Accounting... accounting standards owing to the Financial Accounting Standards Board's Accounting Standards Codification of Generally Accepted Accounting Principles. DATES: Effective Date: February 2, 2012. FOR FURTHER INFORMATION...

  4. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Mingyue, Hu; Hongliao, He [National Research Center for Geoanalysis, Beijing (China)

    2005-10-15

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  5. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    International Nuclear Information System (INIS)

    Hu Mingyue; He Hongliao

    2005-01-01

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  6. Review of neutron activation analysis in the standardization and study of reference materials, including its application to radionuclide reference materials

    International Nuclear Information System (INIS)

    Byrne, A.R.

    1993-01-01

    Neutron activation analysis (NAA) plays a very important role in the certification of reference materials (RMs) and their characterization, including homogeneity testing. The features of the method are briefly reviewed, particularly aspects relating to its completely independent nuclear basis, its virtual freedom from blank problems, and its capacity for self-verification. This last aspect, arising from the essentially isotopic character of NAA, can be exploited by using different nuclear reactions and induced nuclides, and the possibility of employing two modes, one instrumental (nondestructive), the other radiochemical (destructive). This enables the derivation of essentially independent analytical information and the unique capacity of NAA for selfvalidation. The application of NAA to quantify natural or man-made radionuclides such as uranium, thorium, 237 Np, 129 I and 230 Th is discussed, including its advantages over conventional radiometric methods and its usefulness in providing independent data for nuclides where other confirmatory analyses are impossible, or are only recently becoming available through newer 'atom counting' techniques. Certain additional, prospective uses of NAA in the study of RMs and potential RMs are mentioned, including transmutation reactions, creation of endogenously radiolabelled matrices for production and study of RMs (such as dissolution and leaching tests, use as incorporated radiotracers for chemical recovery correction), and the possibility of molecular activation analysis for specification. (orig.)

  7. Agreement between diagnoses reached by clinical examination and available reference standards: a prospective study of 216 patients with lumbopelvic pain

    Directory of Open Access Journals (Sweden)

    Tropp Hans

    2005-06-01

    Full Text Available Abstract Background The tissue origin of low back pain (LBP or referred lower extremity symptoms (LES may be identified in about 70% of cases using advanced imaging, discography and facet or sacroiliac joint blocks. These techniques are invasive and availability varies. A clinical examination is non-invasive and widely available but its validity is questioned. Diagnostic studies usually examine single tests in relation to single reference standards, yet in clinical practice, clinicians use multiple tests and select from a range of possible diagnoses. There is a need for studies that evaluate the diagnostic performance of clinical diagnoses against available reference standards. Methods We compared blinded clinical diagnoses with diagnoses based on available reference standards for known causes of LBP or LES such as discography, facet, sacroiliac or hip joint blocks, epidurals injections, advanced imaging studies or any combination of these tests. A prospective, blinded validity design was employed. Physiotherapists examined consecutive patients with chronic lumbopelvic pain and/or referred LES scheduled to receive the reference standard examinations. When diagnoses were in complete agreement regardless of complexity, "exact" agreement was recorded. When the clinical diagnosis was included within the reference standard diagnoses, "clinical agreement" was recorded. The proportional chance criterion (PCC statistic was used to estimate agreement on multiple diagnostic possibilities because it accounts for the prevalence of individual categories in the sample. The kappa statistic was used to estimate agreement on six pathoanatomic diagnoses. Results In a sample of chronic LBP patients (n = 216 with high levels of disability and distress, 67% received a patho-anatomic diagnosis based on available reference standards, and 10% had more than one tissue origin of pain identified. For 27 diagnostic categories and combinations, chance clinical agreement

  8. Reference standard of penile size and prevalence of buried penis in Japanese newborn male infants.

    Science.gov (United States)

    Matsuo, Nobutake; Ishii, Tomohiro; Takayama, John I; Miwa, Masayuki; Hasegawa, Tomonobu

    2014-01-01

    The present study set forth the reference values for penile size and determined the prevalence of buried penis in Japanese full-term newborns. The stretched penile length was measured and the presence of buried penis was assessed at 1-7 days of age in 547 Japanese full-term newborn infants born between 2008 and 2012 in Tokyo. The stretched penile lengths were compared at 1-12 hours and 1-7 days of age in 63 infants and by two observers in 73 infants to estimate postnatal changes and interobserver variation, respectively. The mean stretched penile length was 3.06 cm (SD, 0.26; 95% confidence interval [CI], 3.04-3.08) and the mean ratio of penile length to body length was 6.24 × 100(-1) (SD, 0.55 × 100(-1)), both of which were significantly smaller than those in Caucasian newborn infants. Buried penis was identified in 20 of 547 infants (3.7%; 95% CI, 2.1-5.2%). The first measurements of penile length at 1-12 hours were significantly smaller than the next measurements at 1-7 days (95% CI of the difference, 0.22-0.34). The 95% CI for the limits of agreement in the penile lengths measured by the two observers was -0.58 to -0.40 for the lower limit and 0.33 to 0.51 for the upper limit. These findings indicate that the penile length should be assessed after 24 hours of age by the reference standard of the same ethnicity for identifying micropenis and that buried penis is not uncommon in Japanese full-term newborns.

  9. An Adaptive Filter for the Removal of Drifting Sinusoidal Noise Without a Reference.

    Science.gov (United States)

    Kelly, John W; Siewiorek, Daniel P; Smailagic, Asim; Wang, Wei

    2016-01-01

    This paper presents a method for filtering sinusoidal noise with a variable bandwidth filter that is capable of tracking a sinusoid's drifting frequency. The method, which is based on the adaptive noise canceling (ANC) technique, will be referred to here as the adaptive sinusoid canceler (ASC). The ASC eliminates sinusoidal contamination by tracking its frequency and achieving a narrower bandwidth than typical notch filters. The detected frequency is used to digitally generate an internal reference instead of relying on an external one as ANC filters typically do. The filter's bandwidth adjusts to achieve faster and more accurate convergence. In this paper, the focus of the discussion and the data is physiological signals, specifically electrocorticographic (ECoG) neural data contaminated with power line noise, but the presented technique could be applicable to other recordings as well. On simulated data, the ASC was able to reliably track the noise's frequency, properly adjust its bandwidth, and outperform comparative methods including standard notch filters and an adaptive line enhancer. These results were reinforced by visual results obtained from real ECoG data. The ASC showed that it could be an effective method for increasing signal to noise ratio in the presence of drifting sinusoidal noise, which is of significant interest for biomedical applications.

  10. 5 CFR 1900.100 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Cross-references to employee ethical... ethical conduct standards and financial disclosure regulations. Officers and employees of the Appalachian Regional Commission Federal Staff are subject to the Standards of Ethical Conduct for Employees of the...

  11. 12 CFR 601.100 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct... employee ethical conduct standards and financial disclosure regulations. Board members, officers, and other employees of the Farm Credit Administration are subject to the Standards of Ethical Conduct for Employees of...

  12. 5 CFR 1633.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Cross-reference to employee ethical... ethical conduct standards and financial disclosure regulations. Employees of the Federal Retirement Thrift Investment Board (Board) are subject to the executive branch-wide Standards of Ethical conduct at 5 CFR part...

  13. 29 CFR 0.735-1 - Cross-references to employee ethical conduct standards, financial disclosure regulations and...

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Cross-references to employee ethical conduct standards, financial disclosure regulations and other ethics regulations. 0.735-1 Section 0.735-1 Labor Office of the Secretary of Labor ETHICS AND CONDUCT OF DEPARTMENT OF LABOR EMPLOYEES Standards of Conduct for Current...

  14. Determination of non-ortho polychlorinated biphenyls in environmental Standard Reference Materials.

    Science.gov (United States)

    Brubaker, W W; Schantz, M M; Wise, S A

    2000-07-01

    The concentrations of three non-ortho ("coplanar") polychlorinated biphenyls, 3,3',4,4'-tetrachlorobiphenyl (IUPAC PCB 77), 3,3',4,4',5-pentachlorobiphenyl (IUPAC PCB 126), and 3,3',4,4',5,5'-hexachlorobiphenyl (IUPAC PCB 169), were determined in five NIST Standard Reference Materials (SRMs) of environmental and biological interest. The measured levels were approximately between (0.2 to 1.3) ng/g in SRM 1588a (Organics in Cod Liver Oil), (0.3 to 9) ng/g in SRM 1944 (New York/New Jersey Waterway Sediment), (0.2 to 0.4) ng/g in SRM 1945 (Organics in Whale Blubber), (1 to 18) ng/g in SRM 2974 (Organics in Freeze-dried Mussel Tissue [Mytilus edulis]), and (0.1 to 0.4) ng/g in candidate SRM 1946 (Lake Superior Fish Tissue). PCB 169 was present at < 0.1 ng/g in SRMs 1944 and 2974.

  15. Standard test method for determination of reference temperature, to, for ferritic steels in the transition range

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of a reference temperature, To, which characterizes the fracture toughness of ferritic steels that experience onset of cleavage cracking at elastic, or elastic-plastic KJc instabilities, or both. The specific types of ferritic steels (3.2.1) covered are those with yield strengths ranging from 275 to 825 MPa (40 to 120 ksi) and weld metals, after stress-relief annealing, that have 10 % or less strength mismatch relative to that of the base metal. 1.2 The specimens covered are fatigue precracked single-edge notched bend bars, SE(B), and standard or disk-shaped compact tension specimens, C(T) or DC(T). A range of specimen sizes with proportional dimensions is recommended. The dimension on which the proportionality is based is specimen thickness. 1.3 Median KJc values tend to vary with the specimen type at a given test temperature, presumably due to constraint differences among the allowable test specimens in 1.2. The degree of KJc variability among specimen types i...

  16. 24 CFR Appendix A to Part 200 - Standards Incorporated by Reference in the Minimum Property Standards for Housing (HUD Handbook...

    Science.gov (United States)

    2010-04-01

    ... 19103, Telephone (215) 299-5400. ASTM C 12-91 Standard Practice for Installing Vitrified Clay Pipe Lines... C 216-91c Standard Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) ASTM.../78 77a Cast Iron Sanitary Drainage System with Hubless Pipe and Fittings—3/28/80 78 Polyethylene (PE...

  17. Re-evaluation and extension of the scope of elements in US Geological Survey Standard Reference Water Samples

    Science.gov (United States)

    Peart, D.B.; Antweiler, Ronald C.; Taylor, Howard E.; Roth, D.A.; Brinton, T.I.

    1998-01-01

    More than 100 US Geological Survey (USGS) Standard Reference Water Samples (SRWSs) were analyzed for numerous trace constituents, including Al, As, B, Ba, Be, Bi, Br, Cd, Cr, Co, Cu, I, Fe, Pb, Li, Mn, Mo, Ni, Rb, Sb, Se, Sr, Te, Tl, U, V, Zn and major elements (Ca, Mg, Na, SiO2, SO4, Cl) by inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry. In addition, 15 USGS SRWSs and National Institute of Standards and Technology (NIST) standard reference material (SRM) 1641b were analyzed for mercury using cold vapor atomic fluorescence spectrometry. Also USGS SRWS Hg-7 was analyzed using isotope dilution-inductively coupled plasma mass spectrometry. The results were compared with the reported certified values of the following standard reference materials: NIST SRM 1643a, 1643b, 1643c and 1643d and National Research Council of Canada Riverine Water Reference Materials for Trace Metals SLRS-1, SLRS-2 and SLRS-3. New concentration values for trace and major elements in the SRWSs, traceable to the certified standards, are reported. Additional concentration values are reported for elements that were neither previously published for the SRWSs nor traceable to the certified reference materials. Robust statistical procedures were used that were insensitive to outliers. These data can be used for quality assurance/quality control purposes in analytical laboratories.

  18. A simple preparation of calibration curve standards of 134Cs and 137Cs by serial dilution of a standard reference material

    International Nuclear Information System (INIS)

    Labrecque, J.J.; Rosales, P.A.

    1990-01-01

    Two sets of calibration standards for 134 Cs and 137 Cs were prepared by small serial dilution of a natural matrix standard reference material, IAEA-154 whey powder. The first set was intended to screen imported milk powders which were suspected to be contaminated with 134 Cs and 137 Cs. Their concentration ranged from 40 to 400 Bq/kg. The other set of calibration standards was prepared to measure the environmental levels of 137 Cs in commercial Venezuelan milk powders. Their concentration ranged from 3 to 10 Bq/kg of 137 Cs. The accuracy of these calibration curves was checked by IAEA-152 and A-14 milk powders. Their measured values were in good agreement with their certified values. Finally, it is shown that these preparation techniques using serial dilution of a standard reference material were simple, rapid, precise, accurate and cost-effective. (author) 5 refs.; 5 figs.; 3 tabs

  19. Reference value standards and primary standards for pH measurements in D2O and aqueous-organic solvent mixtures: new accessions and assessments

    International Nuclear Information System (INIS)

    Mussini, P.R.; Mussini, T.; Rondinini, S.

    1997-01-01

    Recommended Reference Value Standards based on the potassium hydro-genphthalate buffer at various temperatures are reported for pH measurements in various binary solvent mixtures of water with eight organic solvents: methanol, ethanol, 2-propanol, 1,2-ethanediol, 2-methoxyethanol (''methylcellosolve''), acetonitrile, 1,4-dioxane, and dimethyl sulfoxide, together with Reference Value Standard based on the potassium deuterium phthalate buffer for pD measurements in D 2 O. In addition are reported Primary Standards for pH based on numerous buffers in various binary solvent mixtures of water with methanol, ethanol, and dimethyl sulfoxide, together with Primary Standards for pD in D 2 O based on the citrate, phosphate and carbonate buffers. (author)

  20. Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements

    Science.gov (United States)

    Zarr, Robert R; Heckert, N Alan; Leigh, Stefan D

    2014-01-01

    Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg·m−3 to 180 kg·m−3, and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: λ(ρ,T)=a0+a1ρ+a2T+a3T3+a4e−(T−a5a6)2where λ(ρ,T) is the predicted thermal conductivity (W·m−1·K−1), ρ is the bulk density (kg·m−3), T is the mean temperature (K) and ai (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. λ(ρ,T)=a0+a1ρ+a2T One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs. PMID:26601034

  1. Determination of polychlorinated dibenzo-p-dioxin and dibenzofuran congeners in air particulate and marine sediment standard reference materials (SRMs).

    Science.gov (United States)

    Chiu, C H; Turle, R; Poole, G; Thibert, B; Brubaker, W W; Schantz, M M; Wise, S A

    2001-02-01

    Due to the limited number of environmental matrix certified reference materials (CRMs) with assigned values for natural levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), an interlaboratory study was undertaken by the National Institute of Standards and Technology (NIST) and Environment Canada to establish reference concentration values for selected PCDD/Fs in two well-characterized NIST Standard Reference Materials (SRMs): SRM 1649a (Urban Dust) and SRM 1944 (New York/New Jersey Waterway Sediment). Results from 14 laboratories were used to provide reference values for the seventeen 2, 3, 7, 8-substituted PCDD/F congeners, the totals for individual tetra- through hepta-substituted PCDD/F homologues, and the total amount of tetra- through hepta-substituted PCDD/Fs. The mass fractions for the individual 2, 3, 7, 8-substituted congeners range from approximately 0.01 microg/kg to 7 microg/kg dry mass.

  2. MRI of the normal appendix in children: data toward a new reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Swenson, David W. [Alpert Medical School of Brown University and Rhode Island Hospital, Department of Diagnostic Imaging, Providence, RI (United States); Schooler, Gary R. [Duke University Medical Center, Department of Radiology, Durham, NC (United States); Stamoulis, Catherine; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-06-15

    Magnetic resonance imaging (MRI) might prove useful in the diagnostic evaluation of pediatric appendicitis in the effort to avoid exposing children to the ionizing radiation of CT, yet there is a paucity of literature describing the normal range of appearances of the pediatric appendix on MRI. To investigate MRI characteristics of the normal appendix to aid in establishing a reference standard in the pediatric population. We conducted a retrospective study of children and young adults (≤18 years of age) who underwent lumbar spine or pelvis MRI between Jan. 1, 2013, and Dec. 31, 2013, for indications unrelated to appendicitis. Two board-certified radiologists independently reviewed all patients' MRI examinations for appendix visualization, diameter, intraluminal content signal, and presence of periappendiceal inflammation or free fluid. We used the Cohen kappa statistic and Spearman correlation coefficient to assess reader agreement on qualitative and quantitative data, respectively. Three hundred forty-six patients met inclusion criteria. Both readers visualized the appendix in 192/346 (55.5%) patients (kappa = 0.88, P < 0.0001). Estimated median appendix diameter was 5 mm for reader 1 and 6 mm for reader 2 ([25th, 75th] quartiles = [5, 6] mm; range, 2-11 mm; r = 0.81, P < 0.0001). Appendix intraluminal signal characteristics were variable. Periappendiceal inflammation was present in 0/192 (0%) and free fluid in 6/192 (3.1%) MRI examinations (kappa = 1.0). The normal appendix was seen on MRI in approximately half of pediatric patients, with a mean diameter of ∝5-6 mm, variable intraluminal signal characteristics, no adjacent inflammatory changes, and rare surrounding free fluid. (orig.)

  3. Standard and reference materials for environmental science. Part 1. Technical memo

    Energy Technology Data Exchange (ETDEWEB)

    Cantillo, A.Y.

    1995-11-01

    This is the fourth edition of the catalog of reference materials suited for use in environmental science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists more than 1200 reference materials from 28 producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds.

  4. Standard and reference materials for environmental science. Part 2. Technical memo

    Energy Technology Data Exchange (ETDEWEB)

    Cantillo, A.Y.

    1995-11-01

    This is the fourth edition of the catalog of reference materials suited for use in environmental science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists more than 1200 reference materials from 28 producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds.

  5. A Reference Implementation of the OGC CSW EO Standard for the ESA HMA-T project

    Science.gov (United States)

    Bigagli, Lorenzo; Boldrini, Enrico; Papeschi, Fabrizio; Vitale, Fabrizio

    2010-05-01

    This work was developed in the context of the ESA Heterogeneous Missions Accessibility (HMA) project, whose main objective is to involve the stakeholders, namely National space agencies, satellite or mission owners and operators, in an harmonization and standardization process of their ground segment services and related interfaces. Among HMA objectives was the specification, conformance testing, and experimentation of two Extension Packages (EPs) of the ebRIM Application Profile (AP) of the OGC Catalog Service for the Web (CSW) specification: the Earth Observation Products (EO) EP (OGC 06-131) and the Cataloguing of ISO Metadata (CIM) EP (OGC 07-038). Our contributions have included the development and deployment of Reference Implementations (RIs) for both the above specifications, and their integration with the ESA Service Support Environment (SSE). The RIs are based on the GI-cat framework, an implementation of a distributed catalog service, able to query disparate Earth and Space Science data sources (e.g. OGC Web Services, Unidata THREDDS) and to expose several standard interfaces for data discovery (e.g. OGC CSW ISO AP). Following our initial planning, the GI-cat framework has been extended in order to expose the CSW.ebRIM-CIM and CSW.ebRIM-EO interfaces, and to distribute queries to CSW.ebRIM-CIM and CSW.ebRIM-EO data sources. We expected that a mapping strategy would suffice for accommodating CIM, but this proved to be unpractical during implementation. Hence, a model extension strategy was eventually implemented for both the CIM and EO EPs, and the GI-cat federal model was enhanced in order to support the underlying ebRIM AP. This work has provided us with new insights into the different data models for geospatial data, and the technologies for their implementation. The extension is used by suitable CIM and EO profilers (front-end mediator components) and accessors (back-end mediator components), that relate ISO 19115 concepts to EO and CIM ones. Moreover

  6. Quantification of the predominant monomeric catechins in baking chocolate standard reference material by LC/APCI-MS.

    Science.gov (United States)

    Nelson, Bryant C; Sharpless, Katherine E

    2003-01-29

    Catechins are polyphenolic plant compounds (flavonoids) that may offer significant health benefits to humans. These benefits stem largely from their anticarcinogenic, antioxidant, and antimutagenic properties. Recent epidemiological studies suggest that the consumption of flavonoid-containing foods is associated with reduced risk of cardiovascular disease. Chocolate is a natural cocoa bean-based product that reportedly contains high levels of monomeric, oligomeric, and polymeric catechins. We have applied solid-liquid extraction and liquid chromatography coupled with atmospheric pressure chemical ionization-mass spectrometry to the identification and determination of the predominant monomeric catechins, (+)-catechin and (-)-epicatechin, in a baking chocolate Standard Reference Material (NIST Standard Reference Material 2384). (+)-Catechin and (-)-epicatechin are detected and quantified in chocolate extracts on the basis of selected-ion monitoring of their protonated [M + H](+) molecular ions. Tryptophan methyl ester is used as an internal standard. The developed method has the capacity to accurately quantify as little as 0.1 microg/mL (0.01 mg of catechin/g of chocolate) of either catechin in chocolate extracts, and the method has additionally been used to certify (+)-catechin and (-)-epicatechin levels in the baking chocolate Standard Reference Material. This is the first reported use of liquid chromatography/mass spectrometry for the quantitative determination of monomeric catechins in chocolate and the only report certifying monomeric catechin levels in a food-based Standard Reference Material.

  7. Measurement of susceptibility artifacts with histogram-based reference value on magnetic resonance images according to standard ASTM F2119.

    Science.gov (United States)

    Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V

    2015-12-01

    The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.

  8. Sliding and Rocking of Unanchored Components and Structures: Chapter 7.6 ASCE 4 Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    S. R. Jensen

    2011-04-01

    Chapter 7.6 of ASCE 4-Rev 2, Seismic Analysis of Safety-Related Nuclear Structures: Standard and Commentary, provides updated guidance for analysis of rocking and sliding of unanchored structures and components subjected to seismic load. This guidance includes provisions both for simplified approximate energy-based approaches, and for detailed probabilistic time history analysis using nonlinear methods. Factors to be applied to the analytical results are also provided with the intent of ensuring achievement of the 80% non-exceedence probability target of the standard. The present paper surveys the published literature supporting these provisions. The results of available testing and analysis are compared to results produced by both simplified and probabilistic approaches. In addition, adequacy of the standard's provisions for analysis methods and factors is assessed. A comparison is made between the achieved level of conservatism and the standard's non-exceedence probability target.

  9. Determination of technetium-99 in environmental standard reference materials by ICP-MS

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Technetium-99 is an artificial radionuclide which is produced in the fission of 235 U or 239 Pu with a relatively high fission yield of ca. 6%. Because of its long half-life of 2.1 x 10 5 y, 99 Tc has been accumulating in the environment, and thus, is considered to present a potential risk for humans. It is important for dose assessments to identify the behavior of the nuclide in the environment. Analysis data of global fallout 99 Tc in environmental samples would give useful information for predicting the nuclide's behavior; however, due to its low concentration and analytical difficulties, not much data are available. Besides, no environmental standard reference material (SRM) for 99 Tc is available. If we could get suitable SRMs for 99 Tc analysis, it would be easier to determine the concentration of 99 Tc in environmental samples. The purpose of this study was to investigate the possibility of several SRMs to be used as references for low-level 99 Tc. For this, ICP-MS was used for 99 Tc determination. In recent years, ICP-MS has been used for 99 Tc measurements instead of radioactivity counting methods. The samples used were as follows: A) IAEA-373 (a grass sample collected on grassland near Chernobyl Nuclear Power Reactor, Ukraine), B) IAEA-375 (a soil sample collected on a field near Chernobyl Nuclear Power Reactor, Russia), C) IAEA-135 (a sea sediment sample affected by Sellafield, UK), D) five seaweed samples of which the concentration levels are different from each other (collected around the coast near Sellafield, UK). Throughout the chemical separation, 95m Tc was used as a yield monitor. The sample was incinerated for at least 2 h at 450degC. After 99 Tc extraction from the sample at 90degC for 3 h with 4M HNO 3 , the sample was filtered and the residue on the filter was washed with deionized water. The solution was diluted to ca. 0.1M HNO 3 then passed through TEVA resin column (EIChroM Industries, Inc.) to extract Tc onto the resin. Then Tc was

  10. Quine's Double Standard: Undermining the Indispensability Argument via the Indeterminacy of Reference

    Directory of Open Access Journals (Sweden)

    Otávio Bueno

    2003-12-01

    Full Text Available Quine has famously put forward the indispensability argument to force belief in the existence of mathematical objects (such as classes due to their indispensability to our best theories of the world (Quine 1960. Quine has also advocated the indeterminacy of reference argument, according to which reference is dramatically indeterminate: given a language, there’s no unique reference relation for that language (see Quine 1969a. In this paper, I argue that these two arguments are in conflict with each other. Whereas the indispensability argument supports realism about mathematics, the indeterminacy of reference argument, when applied to mathematics, provides a powerful strategy in support of mathematical anti-realism. I conclude the paper by indicating why the indeterminacy of reference phenomenon should be preferred over the considerations regarding indispensability. In the end, even the Quinean shouldn’t be a realist (platonist about mathematics.

  11. 46 CFR 164.023-3 - Specifications and standards incorporated by reference.

    Science.gov (United States)

    2010-10-01

    ... are: Federal Standards and Test Method Standards The following test methods in Federal Test Method Standard No. 191A, Textile Test Methods, July 20, 1978: (1) Method 4010, Length-Weight Relation; Thread..., Polyester Core: Cotton-, Rayon-, or Polyester-Covered, September 30, 1986—164.023-5. (7) MIL-T-43624A—Thread...

  12. Standard and reference materials for marine science. Third edition. Technical memo

    International Nuclear Information System (INIS)

    Cantillo, A.Y.

    1992-08-01

    The third edition of the catalog of reference materials suited for use in marine science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists close to 2,000 reference materials from sixteen producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds. The catalog is being published independently by both NOAA and IOC/UNEP and is available from NOAA/NOS/ORCA in electronic form

  13. Element concentrations in candidate biological and environmental reference materials by k0-standardized INAA

    International Nuclear Information System (INIS)

    Freitas, M.C.

    1993-01-01

    K 0 -Based Neutron Activation Analysis (k 0 INAA) was used to analyze the candidate reference materials Apple Leaves and Peach Leaves, and Oriental Tobacco Leaves and Virginia Tobacco Leaves. Concentration values for 27 elements were measured. The accuracy was ascertained by analysis of two certified reference materials. NIST 1572 Citrus Leaves and 1573 Tomato Leaves. The homogeneity test of the IAEA Evernia prunastri candidate reference material in aliquots ≥ 100 mg is extended to the elements Sc, Cr, Fe, Co, Zn, Rb, Sb, Cs, Ba, Ce and Th. (orig.)

  14. Implementation of a reference standard and proficiency testing programme by the World Wide Antimalarial Resistance Network (WWARN

    Directory of Open Access Journals (Sweden)

    Barnes Karen I

    2010-12-01

    Full Text Available Abstract Background The Worldwide Antimalarial Resistance Network (WWARN is a global collaboration to support the objective that anyone affected by malaria receives effective and safe drug treatment. The Pharmacology module aims to inform optimal anti-malarial drug selection. There is an urgent need to define the drug exposure - effect relationship for most anti-malarial drugs. Few anti-malarials have had their therapeutic blood concentration levels defined. One of the main challenges in assessing safety and efficacy data in relation to drug concentrations is the comparability of data generated from different laboratories. To explain differences in anti-malarial pharmacokinetics in studies with different measurement laboratories it is necessary to confirm the accuracy of the assay methods. This requires the establishment of an external quality assurance process to assure results that can be compared. This paper describes this process. Methods The pharmacology module of WWARN has established a quality assurance/quality control (QA/QC programme consisting of two separate components: 1. A proficiency testing programme where blank human plasma spiked with certified reference material (CRM in different concentrations is sent out to participating bioanalytical laboratories. 2. A certified reference standard programme where accurately weighed amounts of certified anti-malarial reference standards, metabolites, and internal standards are sent to participating bioanalytical and in vitro laboratories. Conclusion The proficiency testing programme is designed as a cooperative effort to help participating laboratories assess their ability to carry out drug analysis, resolve any potential problem areas and to improve their results - and, in so doing, to improve the quality of anti-malarial pharmacokinetic data published and shared with WWARN. By utilizing the same source of standards for all laboratories, it is possible to minimize bias arising from poor

  15. Characterization of human lymphoid cell lines GM9947 and GM9948 as intra- and interlaboratory reference standards for DNA typing

    Energy Technology Data Exchange (ETDEWEB)

    Fregeau, C.J.; Elliott, J.C.; Fourney, R.M. [RCMP Central Forensic Laboratory, Ottawa, Ontario (Canada)] [and others

    1995-07-20

    The incorporation of reference DNA is crucial to the validation of any DNA typing protocol. Currently, reference DNA standards are restricted to molecular size DNA ladders and/or tumor cell line DNA. Either of these, however, presents some limitations. We have rigorously characterized two Epstein-Barr virus (EBV)-immortalized human lymphoid cell lines-GM9947 (female) and GM9948 (male)-to determine their suitability as alternative in-line standards for three widely employed allele profiling strategies. Twenty-one highly polymorphic VNTR-based allelic systems (7 RFLPs, 2 AmpFLPs, and 12 STRs) distributed over 12 chromosomes were scrutinized along with 3 gender-based discriminatory systems. The genetic stability of each locus was confirmed over a period of 225 in vitro population doublings. Allele size estimates and degree of informativeness for each of the 21 VNTR systems were compiled. The reproducibility of allele scoring by traditional RFLP analyses, using both cell lines as reference standards, was also verified by an interlaboratory validation study involving 13 analysts from two geographically distinct forensic laboratories. Taken together, our data indicate that GM9947 and GM9948 genomic DNAs could be adopted as reliable reference standards for DNA typing. 82 refs., 3 figs., 8 tabs.

  16. A NEW APPROACH FOR CULTURING LEMNA MINOR (DUCKWEED) AND STANDARDIZED METHOD FOR USING ATRAZINE AS A REFERENCE TOXICANT

    Science.gov (United States)

    Lemna minor (Duckweed) is commonly used in aquatic toxicity investigations. Methods for culturing and testing with reference toxicants, such as atrazine, are somewhat variable among researchers. Our goal was to develop standardized methods of culturing and testing for use with L....

  17. A preliminary comparative study on the content of cesium, thorium and uranium in IAEA standard reference material

    International Nuclear Information System (INIS)

    Zhang Jing; Liu Husheng; Wang Xiaoyan; Wang Naifen

    2000-01-01

    This paper presents the detection of Cs, Th and U in 6 standard reference materials provided by IAEA, using the ICP-MS method. The bismuth (Bi) was selected as internal standard element for the range compensation of matrix inhibitory effect and flow of the sensibility. The detection limit of the 3 elements was limited in the range of 0.0006∼2ng/ml, 0.4∼0.5g sample was taken and digested by acid, and detected directly by ICP-MS. The recovery of standard addition was 82.1∼100.1%

  18. Standardized Semantic Markup for Reference Terminologies, Thesauri and Coding Systems: Benefits for distributed E-Health Applications.

    Science.gov (United States)

    Hoelzer, Simon; Schweiger, Ralf K; Liu, Raymond; Rudolf, Dirk; Rieger, Joerg; Dudeck, Joachim

    2005-01-01

    With the introduction of the ICD-10 as the standard for diagnosis, the development of an electronic representation of its complete content, inherent semantics and coding rules is necessary. Our concept refers to current efforts of the CEN/TC 251 to establish a European standard for hierarchical classification systems in healthcare. We have developed an electronic representation of the ICD-10 with the extensible Markup Language (XML) that facilitates the integration in current information systems or coding software taking into account different languages and versions. In this context, XML offers a complete framework of related technologies and standard tools for processing that helps to develop interoperable applications.

  19. Sandia National Laboratories Advanced Simulation and Computing (ASC) software quality plan. Part 1: ASC software quality engineering practices, Version 2.0.

    Energy Technology Data Exchange (ETDEWEB)

    Sturtevant, Judith E.; Heaphy, Robert; Hodges, Ann Louise; Boucheron, Edward A.; Drake, Richard Roy; Minana, Molly A.; Hackney, Patricia; Forsythe, Christi A.; Schofield, Joseph Richard, Jr. (,; .); Pavlakos, Constantine James; Williamson, Charles Michael; Edwards, Harold Carter

    2006-09-01

    The purpose of the Sandia National Laboratories Advanced Simulation and Computing (ASC) Software Quality Plan is to clearly identify the practices that are the basis for continually improving the quality of ASC software products. The plan defines the ASC program software quality practices and provides mappings of these practices to Sandia Corporate Requirements CPR 1.3.2 and 1.3.6 and to a Department of Energy document, ASCI Software Quality Engineering: Goals, Principles, and Guidelines. This document also identifies ASC management and software project teams responsibilities in implementing the software quality practices and in assessing progress towards achieving their software quality goals.

  20. Construction of a new growth references for China based on urban Chinese children: comparison with the WHO growth standards.

    Science.gov (United States)

    Zong, Xin-Nan; Li, Hui

    2013-01-01

    Growth references for Chinese children should be updated due to the positive secular growth trends and the progress of the smoothing techniques. Human growth differs among the various ethnic groups, so comparison of the China references with the WHO standards helps to understand such differences. The China references, including weight, length/height, head circumference, weight-for-length/height and body mass index (BMI) aged 0-18 years, were constructed based on 69,760 urban infants and preschool children under 7 years and 24,542 urban school children aged 6-20 years derived from two cross-sectional national surveys. The Cole's LMS method is employed for smoothing the growth curves. The merged data sets resulted in a smooth transition at age 6-7 years and continuity of curves from 0 to 18 years. Varying differences were found on the empirical standard deviation (SD) curves in each indicator at nearly all ages between China and WHO. The most noticeable differences occurred in genders, final height and boundary centiles curves. Chinese boys' weight is strikingly heavier than that of the WHO at age 6-10 years. The height is taller than that of the WHO for boys below 15 years and for girls below 13, but is significantly lower when boys over 15 years and girls over 13. BMI is generally higher than that of the WHO for boys at age 6-16 years but appreciably lower for girls at 3-18 years. The differences between China and WHO are mainly caused by the reference populations of different ethnic backgrounds. For practitioners, the choices of the standards/references depend on the population to be assessed and the purpose of the study. The new China references could be applied to facilitate the standardization assessment of growth and nutrition for Chinese children and adolescents in clinical pediatric and public health.

  1. Comparison of US Birth Weight References and the International Fetal and Newborn Growth Consortium for the 21st Century Standard

    DEFF Research Database (Denmark)

    Kozuki, Naoko; Katz, Joanne; Christian, Parul

    2015-01-01

    ) status. OBJECTIVES: To compare the birth weight distributions of the INTERGROWTH-21st international standard to commonly used US references and examine the differences in the prevalence and neonatal mortality risk of SGA status (below the 10th percentile of a population reference). DESIGN, SETTING...... variance. MAIN OUTCOMES AND MEASURES: We examine neonatal mortality (death within the first 28 days after birth) as the main outcome measure. RESULTS: The pooled SGA prevalence was 23.7% (95% CI, 16.5%-31.0%) using the INTERGROWTH-21st standard compared with 36.0% (95% CI, 27.0%-45.0%) with the US 2000...... and no significant change in the associated neonatal mortality risk, resulting in a decrease in the percentage of neonatal death attributable to SGA. Our study sheds light on how previously published studies on SGA status may be reinterpreted with the introduction of this new birth weight standard....

  2. Completion Report for Multi-Site Incentive MRT 2779 Implement ASC Tripod Initiative by 30SEP08

    Energy Technology Data Exchange (ETDEWEB)

    East, D; Cerutti, J; Noe, J; Cupps, K; Loncaric, J; Sturtevant, J

    2008-09-22

    This report provides documentation and evidence for the completion of the deployment of the Tripod common operating system (TripodOS, also known as and generally referred to below as TOSS). Background documents for TOSS are provided in Appendices A and B, including the initial TOSS proposal accepted by ASC HQ and Executives in July 2007 and a Governance Model defined by a Tri-Lab working group in September 2007. Appendix C contains a document that clarifies the intent and requirements for the completion criteria associated with MRT 2779. The deployment of TOSS is a Multi-Site Incentive from the ASC FY08-09 Implementation Plan due at the end of Quarter 4 in FY08.

  3. Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the electrical performance of photovoltaic modules and arrays under natural or simulated sunlight using a calibrated reference cell. 1.1.1 These test methods allow a reference module to be used instead of a reference cell provided the reference module has been calibrated using these test methods against a calibrated reference cell. 1.2 Measurements under a variety of conditions are allowed; results are reported under a select set of reporting conditions (RC) to facilitate comparison of results. 1.3 These test methods apply only to nonconcentrator terrestrial modules and arrays. 1.4 The performance parameters determined by these test methods apply only at the time of the test, and imply no past or future performance level. 1.5 These test methods apply to photovoltaic modules and arrays that do not contain series-connected photovoltaic multijunction devices; such module and arrays should be tested according to Test Methods E 2236. 1.6 The values stated in SI units are to be re...

  4. Polycyclic aromatic hydrocarbons (PAHs) in a coal tar standard reference material - SRM 1597a updated

    Energy Technology Data Exchange (ETDEWEB)

    Wise, Stephen A.; Poster, Dianne L.; Rimmer, Catherine A.; Schubert, Patricia; Sander, Lane C.; Schantz, Michele M. [National Institute of Standards and Technology (NIST), Analytical Chemistry Division, Gaithersburg, MD (United States); Leigh, Stefan D. [National Institute of Standards and Technology (NIST), Statistical Engineering Division, Gaithersburg, MD (United States); Moessner, Stephanie [National Institute of Standards and Technology (NIST), Analytical Chemistry Division, Gaithersburg, MD (United States); GMP/Comparator Labs, Werthenstein Chemie AG, Industrie Nord, Schachen (Switzerland)

    2010-09-15

    SRM 1597 Complex Mixture of Polycyclic Aromatic Hydrocarbons from Coal Tar, originally issued in 1987, was recently reanalyzed and reissued as SRM 1597a with 34 certified, 46 reference, and 12 information concentrations (as mass fractions) for polycyclic aromatic hydrocarbons (PAHs) and polycyclic aromatic sulfur heterocycles (PASHs) including methyl-substituted PAHs and PASHs. The certified and reference concentrations (as mass fractions) were based on results of analyses of the coal tar material using multiple analytical techniques including gas chromatography/mass spectrometry on four different stationary phases and reversed-phase liquid chromatography. SRM 1597a is currently the most extensively characterized SRM for PAHs and PASHs. (orig.)

  5. Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers a procedure for the determination of a spectral mismatch parameter used in performance testing of photovoltaic devices. 1.2 The spectral mismatch parameter is a measure of the error, introduced in the testing of a photovoltaic device, caused by mismatch between the spectral responses of the photovoltaic device and the photovoltaic reference cell, as well as mismatch between the test light source and the reference spectral irradiance distribution to which the photovoltaic reference cell was calibrated. Examples of reference spectral irradiance distributions are Tables E490 or G173. 1.3 The spectral mismatch parameter can be used to correct photovoltaic performance data for spectral mismatch error. 1.4 This test method is intended for use with linear photovoltaic devices. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, a...

  6. Determining the normal range for IGF-I, IGFBP-3, and ALS: new reference data based on current internal standards.

    Science.gov (United States)

    Ertl, Diana-Alexandra; Gleiss, Andreas; Sagmeister, Susanne; Haeusler, Gabriele

    2014-09-01

    The measurement of insulin-like growth factors (IGF-I) and insulin-like growth factor-binding protein (IGFBP-3) often serves as first-line testing in children with growth disorders. The role of acid-labile subunit (ALS) as a screening parameter for homozygous or heterozygous mutations of the ALS gene still has to be determined. IGF-I, IGFBP-3, and ALS were measured in 252 samples from children and adolescents. Reference curves were fitted using generalized additive model for location, scale and shape (GAMLSS) models and SD-Scores were calculated. Bootstrap analysis was used to quantify the uncertainty of the estimated percentiles. Bland-Altman plots were used to investigate the discrepancy between our newly estimated standard deviation scores (SDS) and SDS calculated on the basis of previous reference data. We present reference data for enzyme-linked immunosorbent assay (ELISA) measurements based on recommended internal standard for IGF-I, IGFBP-3, and ALS suitable for calculation of SD-scores. The Bland-Altman plot shows a rough agreement between the previous SDS calculation and our new one only for SDS around 1; for SDS at -2, an average difference of 0.83 SD was noticed. Our IGF-I reference values for the interval of interest in diagnosing growth hormone deficiency (GHD) (prepubertal age) are solid as proved by bootstrap analysis. The difference in calculated SD scores by using data provided previously highlights the importance of using labor and method specific reference data.

  7. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference.

    Directory of Open Access Journals (Sweden)

    Helen L Storey

    Full Text Available Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates.

  8. Development and testing of standardized procedures and reference data for LWR surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.

    1979-02-01

    The resources and talents of many national and international organizations and laboratories, both governmental and industrial, are being used to establish analysis methods for predicting the embrittlement condition of light water reactor (LWR) primary systems. The exact interrelationships and responsibilities between those developing, understanding, combining, and applying state-of-the-art technology in dosimetry, metallurgy, and fracture mechanics for reactor systems analysis are being carefully reviewed and studied. This has resulted in a more comprehensive definition of the scope of new and updated ASTM standards required for the analysis and interpretation of LWR pressure vessel surveillance results. Fifteen new and updated ASTM standards have now been identified, together with a restructuring of the main interfaces between the individual standard practices, guides, and methods. The paper briefly discusses these standards and the initial results of multi-laboratory research work involved in their validation and calibration

  9. Fathead minnows (Pimephales promelas) and goldfish (Carassius auratus) as standard fish in bioassays and their reaction to potential reference toxicants

    Energy Technology Data Exchange (ETDEWEB)

    Adelman, I.R.; Smith, L.L. Jr.

    1976-02-01

    Fathead minnows (Pimephales promelas) and goldfish (Carassius auratus) were compared for their suitability as standard bioassay fish. Both species showed the same variability of bioassay results when tested with four toxicants. Fathead minnows are recommended on the basis of their small size and on their capability for use in complete life cycle tests. On the basis of minimum variability of bioassay results, sodium chloride was superior for use as a reference toxicant. Both sodium chloride and pentachlorophenol seemed capable of detecting abnormal fish. On the basis of seven listed criteria either sodium chloride or pentachlorophenol would be acceptable as a reference toxicant.

  10. Assessing reference evapotranspiration in a subhumid climate in NE Austria

    Science.gov (United States)

    Nolz, Reinhard; Eitzinger, Josef; Cepuder, Peter

    2015-04-01

    Computing reference evapotranspiration and multiplying it with a specific crop coefficient as recommended by the Food and Agriculture Organization of the United Nations (FAO) is the most widely accepted approach to estimate plant water requirements. The standardized form of the well-known FAO Penman-Monteith equation, published by the Environmental and Water Resources Institute of the American Society of Civil Engineers (ASCE-EWRI), is recommended as a standard procedure for calculating reference evapotranspiration. Applied and validated under different climatic conditions it generally achieved good results compared to other methods. However, several studies documented deviations between measured and calculated reference evapotranspiration depending on local environmental conditions. Consequently, it seems advisable to evaluate the model under local environmental conditions. Evapotranspiration was determined at a subhumid site in Austria (48°12'N, 16°34'E; 157 m asl) using a large weighing lysimeter operated at (limited) reference conditions and compared with calculations according to ASCE-EWRI. The lysimeter had an inner diameter of 1.9 m and a hemispherical bottom with a maximum depth of 2.5 m. Seepage water was measured at a free draining outlet using a tipping bucket. Lysimeter mass changes were sensed by a weighing facility with an accuracy of ±0.1 mm. Both rainfall and evapotranspiration were determined directly from lysimeter data using a simple water balance equation. Meteorological data for the ASCE-EWRI model were obtained from a weather station of the Central Institute for Meteorology and Geodynamics, Austria (ZAMG). The study period was from 2005 to 2010, analyses were based upon daily time steps. Daily calculated reference evapotranspiration was generally overestimated at small values, whereas it was rather underestimated when evapotranspiration was large, which is supported also by other studies. In the given case, advection of sensible heat proved

  11. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme.

    Science.gov (United States)

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2016-11-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R 2  = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R 2  = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.

  12. Uncertainty Analysis of Spectral Irradiance Reference Standards Used for NREL Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Habte, A.; Andreas, A.; Reda, I.; Campanelli, M.; Stoffel, T.

    2013-05-01

    Spectral irradiance produced by lamp standards such as the National Institute of Standards and Technology (NIST) FEL-type tungsten halogen lamps are used to calibrate spectroradiometers at the National Renewable Energy Laboratory. Spectroradiometers are often used to characterize spectral irradiance of solar simulators, which in turn are used to characterize photovoltaic device performance, e.g., power output and spectral response. Therefore, quantifying the calibration uncertainty of spectroradiometers is critical to understanding photovoltaic system performance. In this study, we attempted to reproduce the NIST-reported input variables, including the calibration uncertainty in spectral irradiance for a standard NIST lamp, and quantify uncertainty for measurement setup at the Optical Metrology Laboratory at the National Renewable Energy Laboratory.

  13. NASA/NBS (National Aeronautics and Space Administration/National Bureau of Standards) standard reference model for telerobot control system architecture (NASREM)

    Science.gov (United States)

    Albus, James S.; Mccain, Harry G.; Lumia, Ronald

    1989-01-01

    The document describes the NASA Standard Reference Model (NASREM) Architecture for the Space Station Telerobot Control System. It defines the functional requirements and high level specifications of the control system for the NASA space Station document for the functional specification, and a guideline for the development of the control system architecture, of the 10C Flight Telerobot Servicer. The NASREM telerobot control system architecture defines a set of standard modules and interfaces which facilitates software design, development, validation, and test, and make possible the integration of telerobotics software from a wide variety of sources. Standard interfaces also provide the software hooks necessary to incrementally upgrade future Flight Telerobot Systems as new capabilities develop in computer science, robotics, and autonomous system control.

  14. The development and certification of Standard Reference Materials (SRMs) to assess and ensure accurate measurement of Pb in the environment.

    Science.gov (United States)

    Fassett, J D; MacDonald, B S

    2001-08-01

    The National Institute of Standards and Technology (NIST) has had a major quality-assurance role in the federal effort to reduce lead poisoning of children in the United States through its mission of ensuring the accuracy of chemical measurements. NIST certifies reference materials (standard reference materials--SRMs) that are used to benchmark measurements by secondary and field methods of analysis--to ensure that decisions of great health and economic impact are soundly based on good measurement science. Over the past 10 years, in cooperation with the US Environmental Protection Agency (EPA), US Department of Housing and Urban Development (HUD), and the United States Geological Survey (USGS), NIST has prepared and certified SRMs for lead content in soil, indoor dust, and paint. The role of these materials in meeting regulatory and abatement needs is described and their certified values are summarized.

  15. Thermal conductivity and electrical resistivity standard reference materials: tungsten SRM's 730 and 799, from 4 to 30000K. Final report

    International Nuclear Information System (INIS)

    Hust, J.G.; Giarratano, P.J.

    1975-09-01

    A historical review of the development of thermophysical Standard Reference Materials, SRM's, is given and selection criteria of SRM's are listed. Thermal conductivity and electrical resistivity data for arc cast and sintered tungsten are compiled, analyzed, and correlated. Recommended values of thermal conductivity (SRM 730) and electrical resistivity (SRM 799) for these lots of tungsten are presented for the range 4 to 3000 0 K

  16. Safety evaluation report related to the preliminary design of the Standard Reference System, RESAR-414

    International Nuclear Information System (INIS)

    1978-11-01

    The safety evaluation for the Westinghouse Standard Reactor includes information on general reactor characteristics; design criteria for systems and components; reactor coolant system; engineered safety systems; instrumentation and controls; electric power systems; auxiliary systems; steam and power conversion system; radioactive waste management; radiation protection; conduct of operations; accident analyses; and quality assurance

  17. 77 FR 751 - Federal Motor Vehicle Safety Standards; Matters Incorporated by Reference

    Science.gov (United States)

    2012-01-06

    ... Recommended Practice J1133, ``School Bus Stop Arm,'' revised April 1984, into Sec. 571.131. (45) SAE Standard... constriction requirement of S5.3.1 after having been subjected to a temperature of 248 degrees Fahrenheit (120... mandatory requirements. * * * * * S6.4.5 School bus signal lamp aiming. Each school bus signal lamp must be...

  18. 75 FR 48593 - Pipeline Safety: Periodic Updates of Regulatory References to Technical Standards and...

    Science.gov (United States)

    2010-08-11

    ... (ASTM): ASTM A53/A53M-07 (2007), ``Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless'' (September 1, 2007). Replaces IBR: 2004 edition; Referenced in 49 CFR 192...), we clarify that cast iron, malleable iron, or ductile iron may be used in the valve ball or plug...

  19. Determinants of teenage smoking, with special reference to non-standard family background.

    Science.gov (United States)

    Isohanni, M; Moilanen, I; Rantakallio, P

    1991-04-01

    The prevalence of teenage smoking in a cohort of 12,058 subjects born in northern Finland in 1966 is discussed in terms of its social and family determinants, especially in "non-standard" families (with one or more of the parents absent for at least part of the child's upbringing). The prevalence of experimental or daily smoking was 67.4%, the rate being 65.5% in the standard, two-parent families and 75.5% in the non-standard families, the difference being statistically significant (p less than 0.001). The corresponding prevalence of daily smoking was 6.4%, but the rate was 5.1% in standard families and 12.1% in non-standard families (p less than 0.001). An elevated risk of smoking existed among adolescents who had experienced death of their father or divorce of their parents and among girls who had experienced death of their mother. Maternal smoking during pregnancy and maternal age under 20 years at the time of delivery increased the risk, while being the first-born child reduced it. Among family factors existing in 1980, paternal smoking increased the risk for both sexes, while more than three siblings, mother's unemployment or gainful employment (i.e. not a housewife) were associated with smoking by the boys as was urban living, and for the girls migration by the family to a town. The results suggest that juvenile smoking may be a kind of indicator of possible problems experienced by the parents and/or the adolescents themselves with respect to parenthood and family development.

  20. Standard reference radiographs for steel castings up to 2 in. (50.8 mm) in thickness

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes accepted procedures for and factors that influence laboratory immersion corrosion tests, particularly mass loss tests. These factors include specimen preparation, apparatus, test conditions, methods of cleaning specimens, evaluation of results, and calculation and reporting of corrosion rates. This practice also emphasizes the importance of recording all pertinent data and provides a checklist for reporting test data. Other ASTM procedures for laboratory corrosion tests are tabulated in the Appendix. (Warning-In many cases the corrosion product on the reactive metals titanium and zirconium is a hard and tightly bonded oxide that defies removal by chemical or ordinary mechanical means. In many such cases, corrosion rates are established by mass gain rather than mass loss.) 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, assoc...

  1. Reference Material Properties and Standard Problems to Verify the Fuel Performance Models Ver 1.0

    International Nuclear Information System (INIS)

    Yang, Yong Sik; Kim, Jae Yong; Koo, Yang Hyun

    2010-12-01

    All fuel performance models must be validated by in-pile and out-pile tests. However, the model validation requires much efforts and times to confirm its exactness. In many fields, new performance models and codes are confirmed by code-to-code benchmarking process under simplified standard problem analysis. At present, the DUOS, which is the steady state fuel performance analysis code for dual cooled annular fuel, development project is progressing and new FEM module is developed to analyze the fuel performance during transient period. In addition, the verification process is planning to examine the new models and module's rightness by comparing with commercial finite element analysis such as a ADINA, ABAQUS and ANSYS. This reports contains the result of unification of material properties and establishment of standard problem to verify the newly developed models with commercial FEM code

  2. Determinations of silicon and phosphorus in Pepperbush standard reference material by neutron activation and x-ray fluorescence methods

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Nishio, Hirofumi; Hayashi, Takeshi; Kusakabe, Toshio; Iwata, Shiro.

    1987-01-01

    Silicon and phosphorus contents in Pepperbush standard reference material were determined by neutron activation and X-ray fluorescence methods. In neutron activation analysis, β-ray spectra of 32 P produced by 31 P(n,γ) 32 P reaction on Pepperbush and standard samples were measured by a low background β-ray spectrometer. In X-ray fluorescence analysis, the standard samples were prepared by mixing the Pepperbush powder with silicon dioxide and diammonium hydrogenphosphate. Characteristic X-rays from the samples were analyzed by a wavelength dispersive X-ray fluorescence spectrometer. From the β and X-ray intensities, silicon and phosphorus contents in Pepperbush were determined to be 1840 ± 80 and 1200 ± 50 μg g -1 , respectively. (author)

  3. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    Science.gov (United States)

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  4. The uncertainty of reference standards--a guide to understanding factors impacting uncertainty, uncertainty calculations, and vendor certifications.

    Science.gov (United States)

    Gates, Kevin; Chang, Ning; Dilek, Isil; Jian, Huahua; Pogue, Sherri; Sreenivasan, Uma

    2009-10-01

    Certified solution standards are widely used in forensic toxicological, clinical/diagnostic, and environmental testing. Typically, these standards are purchased as ampouled solutions with a certified concentration. Vendors present concentration and uncertainty differently on their Certificates of Analysis. Understanding the factors that impact uncertainty and which factors have been considered in the vendor's assignment of uncertainty are critical to understanding the accuracy of the standard and the impact on testing results. Understanding these variables is also important for laboratories seeking to comply with ISO/IEC 17025 requirements and for those preparing reference solutions from neat materials at the bench. The impact of uncertainty associated with the neat material purity (including residual water, residual solvent, and inorganic content), mass measurement (weighing techniques), and solvent addition (solution density) on the overall uncertainty of the certified concentration is described along with uncertainty calculations.

  5. Direct calibration of GC/MS systems using SRM (Standard Reference Material) gas cylinders. Project report, January 1984-August 1985

    International Nuclear Information System (INIS)

    Byrd, G.D.; Richie, K.L.; Sniegoski, L.T.; White, E.

    1985-10-01

    A cryogenic trapping system has been developed for use in calibrating GC/MS systems for the analysis of volatile organic compounds. This system provides for direct Standard Reference Material (SRM) traceability on data generated on gaseous samples. The cryogenic trap is a coil of stainless steel tubing immersed in a cryogen to trap and preconcentrate organic species present in a gaseous sample. The trap also contains a heated injection port for the addition of isotopically labeled compounds for use in isotope dilution measurements. The first part of this research is concerned with the development of IDMS as an independent method for the quantification of analytes in gaseous samples to be used as standards. Results are presented for the determination of bromobenzene in nitrogen at nominal concentrations of 1 and 25 ppb. In the second part of the research, a calibration curve method was developed for using these standards in auditing the performance of GC/MS systems

  6. Determinations of elements in pepperbush standard reference material by neutron activation and X-ray fluorescence analyses

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Okada, Takayuki; Tatsumi, Toshiya; Kusakabe, Toshio; Katsurayama, Kousuke; Iwata, Shiro.

    1988-01-01

    Elemental contents in Pepperbush standard reference material have been determined by neutron activation and X-ray fluorescence analyses. The standard samples of orchard leaves, tomato leaves, pine needles and Kale are used for the experiment. In the neutron activation analysis, gamma-ray spectra of nuclei produced by (n,γ) reaction on Pepperbush and standard samples are measured with Ge detectors. In the X-ray fluorescence analysis, the samples are excited with X-rays from X-ray tube with rhodium anode, and the characteristic X-rays from samples are measured with a proportional counter or NaI(Tl) detector. From the gamma- and X-ray intensities, the elemental contents in Pepperbush are determined. As a result, the contents of seventeen elements, such as sodium, calcium, iron, etc., in Pepperbush are determined. (author)

  7. Development of a standard reference material containing 22 chlorinated hydrocarbon gases at 1 μmol/mol in nitrogen.

    Science.gov (United States)

    Li, Ning; Du, Jian; Yang, Jing; Fan, Qiang; Tian, Wen

    2017-11-01

    A gas standard mixture containing 22 chlorinated hydrocarbons in high purity nitrogen was prepared using a two-step weighing method and a gasifying apparatus developed in-house. The concentration of each component was determined using a gas chromatograph with flame ionization detection (GC/FID). Linear regression analysis of every component was performed using the gas standard mixture with concentrations ranging from 1 to 10 μmol/mol, showing the complete gasification of volatile organic compound (VOCs) species in a selected cylinder. Repeatability was also examined to ensure the reliability of the preparation method. In addition, no significant difference was observed between domestic treated and imported treated cylinders, which were conducive to reduction of the cost of raw materials. Moreover, the results of stability testing at different pressures and long-term stability tests indicated that the gas standard at 1 μmol/mol level with relative expanded uncertainties of 5% was stable above 2 MPa for a minimum of 12 months. Finally, a quantity comparison was conducted between the gas standard and a commercial gas standard from Scott Specialty Gases (now Air Liquide America Specialty Gases). The excellent agreement of every species suggested the favorable accuracy of our gas standard. Therefore, this reference material can be applied to routine observation of VOCs and for other purposes.

  8. A contemporary Colombian skeletal reference collection: A resource for the development of population specific standards.

    Science.gov (United States)

    Sanabria-Medina, Cesar; González-Colmenares, Gretel; Restrepo, Hadaluz Osorio; Rodríguez, Juan Manuel Guerrero

    2016-09-01

    Several authors who have discussed human variability and its impact on the forensic identification of bodies pose the need for regional studies documenting the global variation of the attributes analyzed osteological characteristics that aid in establishing biological profile (sex, ancestry, biological age and height). This is primarily accomplished by studying documented human skeletal collections in order to investigate secular trends in skeletal development and aging, among others in the Colombian population. The purpose of this paper is to disclose the details of the new "Contemporary Colombian Skeletal Reference Collection" that currently comprises 600 identified skeletons of both sexes, who died between 2005 and 2008; and which contain information about their cause of death. This collection has infinite potential for research, open to the national and international community, and still has pending opportunities to address a variety of topics such as studies on osteopathology, bone trauma and taphonomic studies. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Impact of a product-specific reference standard for the measurement of a PEGylated rFVIII activity: the Swiss Multicentre Field Study.

    Science.gov (United States)

    Bulla, O; Poncet, A; Alberio, L; Asmis, L M; Gähler, A; Graf, L; Nagler, M; Studt, J-D; Tsakiris, D A; Fontana, P

    2017-07-01

    Measuring factor VIII (FVIII) activity can be challenging when it has been modified, such as when FVIII is pegylated to increase its circulating half-life. Use of a product-specific reference standard may help avoid this issue. Evaluate the impact of using a product-specific reference standard for measuring the FVIII activity of BAX 855 - a pegylated FVIII - in eight of Switzerland's main laboratories. Factor VIII-deficient plasma, spiked with five different concentrations of BAX 855, plus a control FVIII sample, was sent to the participating laboratories. They measured FVIII activity by using either with a one-stage (OSA) or the chromogenic assay (CA) against their local or a product-specific reference standard. When using a local reference standard, there was an overestimation of BAX 855 activity compared to the target concentrations, both with the OSA and CA. The use of a product-specific reference standard reduced this effect: mean recovery ranged from 127.7% to 213.5% using the OSA with local reference standards, compared to 110% to 183.8% with a product-specific reference standard, and from 146.3% to 182.4% using the CA with local reference standards compared to 72.7% to 103.7% with a product-specific reference standard. In this in vitro study, the type of reference standard had a major impact on the measurement of BAX 855 activity. Evaluation was more accurate and precise when using a product-specific reference standard. © 2017 John Wiley & Sons Ltd.

  10. Design and realization of the high-precision weighing systems as the gravimetric references in PTB's national water flow standard

    International Nuclear Information System (INIS)

    Engel, Rainer; Beyer, Karlheinz; Baade, Hans-Joachim

    2012-01-01

    PTB's ‘Hydrodynamic Test Field’, which represents a high-accuracy water flow calibration facility, serves as the national primary standard for liquid flow measurands. As the core reference device of this flow facility, a gravimetric standard has been incorporated, which comprises three special-design weighing systems: 300 kg, 3 tons and 30 tons. These gravimetric references were realized as a combination of a strain-gauge-based and an electromagnetic-force-compensation load-cell-based balance, each. Special emphasis had to be placed upon the dynamics design of the whole weighing system, due to the high measurement resolution and the dynamic behavior of the weighing systems, which are dynamically affected by mechanical vibrations caused by environmental impacts, flow machinery operation, flow noise in the pipework and induced wave motions in the weigh tanks. Taking into account all the above boundary conditions, the design work for the gravimetric reference resulted in a concrete foundation ‘rock’ of some 300 tons that rests on a number of vibration isolators. In addition to these passively operating vibration isolators, the vibration damping effect is enhanced by applying an electronic level regulation device. (paper)

  11. Body mass index in Saudi Arabian children and adolescents: A national reference and comparison with international standards

    International Nuclear Information System (INIS)

    Al Herbish, Abdullah S; ElMouzan, Mohammed I; AlSalloum, Abdullah A; AlQureshi, Mansour M; AlOmar, Ahmed A; Fster, Peter J; Kecojevic, Tatjana

    2009-01-01

    Because there are no reference standards for body mass index (BMI) in Saudi children, we established BMI reference percentiles for normal Saudi Arabian children and adolescents and compared them with international standards. Data from a stratified multistage probability sample were collected from the 13 health regions in Saudi Arabia, as part of a nationwide health profile survey of Saudi Arabian children and adolescents conducted to establish normal physical growth references. Selected households were visited by a trained team. Weight and length/height were measured and recorded following the WHO recommended procedures using the same equipment, which were subjected to both calibration and intra/interobserver variations. Survey of 11 874 eligible households yielded 35 275 full-term and healthy children and adolescents who were subjected to anthropometric measurements. Four BMI curves were produced, from birth to 36 months and 2 to 19 years for girls and boys. The 3rd, 5th, 10th ,25th , 5oth , 75th ,85th , 90th , 95th , and 97th percentiles were produced and compared with the WHO and CDC BMI charts. In the higher percentiles, the Saudi children differed from Western counterparts, indicating that Saudi children have equal or higher BMIs. The BMI curves reflect statistically representative BMI values for Saudi Arabian children and adolescents. (author)

  12. A Proposal of New Reference System for the Standard Axial, Sagittal, Coronal Planes of Brain Based on the Serially-Sectioned Images

    Science.gov (United States)

    Park, Jin Seo; Park, Hyo Seok; Shin, Dong Sun; Har, Dong-Hwan; Cho, Zang-Hee; Kim, Young-Bo; Han, Jae-Yong; Chi, Je-Geun

    2010-01-01

    Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes. PMID:20052359

  13. Mercury Trapped Ion Frequency Standard for Ultra-Stable Reference Applications

    Science.gov (United States)

    Burt, Eric A. (Inventor); Hamell, Robert L. (Inventor); Tucker, Blake C. (Inventor); Larsen, Kameron (Inventor); Tjoelker, Robert L. (Inventor)

    2017-01-01

    An atomic clock including an ion trap assembly, a C-field coil positioned for generating a first magnetic field in the interrogation region of the ion trap assembly, a compensation coil positioned for generating a second magnetic field in the interrogation region, wherein the combination of the first and second magnetic fields produces an ion number-dependent second order Zeeman shift (Zeeman shift) in the resonance frequency that is opposite in sign to an ion number-dependent second order Doppler shift (Doppler shift) in the resonance frequency, the C-field coil has a radius selected using data indicating how changes in the radius affect an ion-number-dependent shift in the resonance frequency, such that a difference in magnitude between the Doppler shift and the Zeeman shift is controlled or reduced, and the resonance frequency, including the adjustment by the Zeeman shift, is used to obtain the frequency standard.

  14. Effective thermal conductivity of glass-fiber board and blanket standard reference materials

    International Nuclear Information System (INIS)

    Smith, D.R.; Hust, J.G.

    1983-01-01

    This chapter reports on measurements of effective thermal conductivity performed on a series of specimens of glass-fiber board and glass-fiber blanket. Explains that measurements of thermal conductivity were conducted as a function of temperature from 85 to 360 K, of temperature difference with T=10 to 100 K, of bulk density from 11 to 148 kg/m 3 and for nitrogen, argon, and helium inter-fiber fill gases at pressures from atmospheric to high vacuum. Analyzes and compares results with values from the published literature and National Bureau of Standards (NBS) certification data for similar material. Gives polynomial expressions for the functional relation between conductivity, temperature, and density for board and for blanket

  15. Event-specific qualitative and quantitative detection of five genetically modified rice events using a single standard reference molecule.

    Science.gov (United States)

    Kim, Jae-Hwan; Park, Saet-Byul; Roh, Hyo-Jeong; Shin, Min-Ki; Moon, Gui-Im; Hong, Jin-Hwan; Kim, Hae-Yeong

    2017-07-01

    One novel standard reference plasmid, namely pUC-RICE5, was constructed as a positive control and calibrator for event-specific qualitative and quantitative detection of genetically modified (GM) rice (Bt63, Kemingdao1, Kefeng6, Kefeng8, and LLRice62). pUC-RICE5 contained fragments of a rice-specific endogenous reference gene (sucrose phosphate synthase) as well as the five GM rice events. An existing qualitative PCR assay approach was modified using pUC-RICE5 to create a quantitative method with limits of detection correlating to approximately 1-10 copies of rice haploid genomes. In this quantitative PCR assay, the square regression coefficients ranged from 0.993 to 1.000. The standard deviation and relative standard deviation values for repeatability ranged from 0.02 to 0.22 and 0.10% to 0.67%, respectively. The Ministry of Food and Drug Safety (Korea) validated the method and the results suggest it could be used routinely to identify five GM rice events. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. [Personalizing the reference level: gold standard to evaluate the quality of service perceived].

    Science.gov (United States)

    Rodrigo-Rincón, I; Reyes-Pérez, M; Martínez-Lozano, M E

    2014-01-01

    To know the cutoff point at which in-house Nuclear Medicine Department (MND) customers consider that the quality of service is good (personalized cutoff). We conducted a survey of the professionals who had requested at least 5 tests to the Nuclear Medicine Department. A total of 71 doctors responded (response rate: 30%). A question was added to the questionnaire for the user to establish a cutoff point for which they would consider the quality of service as good. The quality non-conformities, areas of improvement and strong points of the six questions measuring the quality of service (Likert scale 0 to 10) were compared with two different thresholds: personalized cutoff and one proposed by the service itself a priori. Test statistics: binomial and Student's t-test for paired data. A cutoff value of 7 was proposed by the service as a reference while 68.1% of respondents suggested a cutoff above 7 points (mean 7.9 points). The 6 elements of perceived quality were considered strong points with the cutoff proposed by the MND, while there were 3 detected with the personalized threshold. Thirteen percent of the answers were nonconformities with the service cutoff versus 19.2% with the personalized one, the differences being statistically significant (difference 95% CI 6.44%:0,83-12.06). The final image of the perceived quality of an in-house customer is different when using the cutoff established by the Department versus the personalized cutoff given by the respondent. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  17. Occupational hazard: radiation exposure for the urologist: developing a reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Seth A.; Rangarajan, Sriram S.; Chen, Tony; Palazzi, Kerrin L.; Langford, J. Scott; Sur, Roger L., E-mail: rlsur@ucsd.edu [Department of Surgery and Division of Urology, U C San Diego Health Science System, San Diego, CA (United States)

    2013-03-15

    Introduction: to date, there is a paucity of literature offering practicing urologists a reference for the amount of radiation exposure received while surgically managing urolithiasis. This study examines the cumulative radiation exposure of an urologist over 9 months. Materials and methods: We present a case series of fluoroscopic exposures of an experienced stone surgeon operating at an academic comprehensive stone center between April and December 2011. Radiation exposure measurements were determined by a thermoluminescent dosimeter worn on the outside of the surgeon's thyroid shield. Estimations of radiation exposure (mrem) per month were charted with fluoroscopy times, using scatter plots to estimate Spearman's rank correlation coefficients. Results: the total 9-month radiation exposure was 87 mrems for deep dose equivalent (DDE), 293 mrem for lens dose equivalent (LDE), and 282 mrem for shallow dose equivalent (SDE). Total fluoroscopy time was 252.44 minutes for 64 ureteroscopies (URSs), 29 percutaneous nephrolithtomies (PNLs), 20 cystoscopies with ureteral stent placements, 9 shock wave ithotripsies (SWLs), 9 retrograde pyelograms (RPGs), 2 endoureterotomies, and 1 ureteral balloon dilation. Spearman's rank correlation coefficients examining the association between fluoroscopy time and radiation exposure were not significant for DDE (p = 0.6, Spearman's rho = 0.2), LDE (p = 0.6, Spearman's rho = 0.2), or SDE (p = 0.6, Spearman's rho = 0.2). Conclusions: Over a 9-month period, total radiation exposures were well below annual accepted limits (DDE 5000 mrem, LDE 15,000 mrem and SDE 50,000 mrem). Although fluoroscopy time did not correlate with radiation exposure, future prospective studies can account for co-variates such as patient obesity and urologist distance from radiation source. (author)

  18. The standardisation of trace elements in international biological standard reference materials with neutron activation analysis and atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Pieterse, H.

    1981-12-01

    An investigation was undertaken into the analytical procedures and the identification of problem areas, for the certification of a new biological standard reference material supplied by the International Atomic Energy Agency, namely, a human hair sample designated as HH-I. The analyses comprised the determination of the elements As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Sb, Se, and Zn in the hair sample by using two analytical techniques, namely, Instrumental Neutron Activation Analysis and Atomic Absorption. Three other certified biological reference materials, namely, Orchard Leaves (ORCH-L), Sea Plant Material (SPM-I) and Copepod (MAA-I) were used as control standards. Determinations were made of the moisture content of the samples, using varying conditions of drying, and the necessary corrections were applied to all analytical results so that the final elemental values related to dry weight of samples. Attention was also given to the possible loss of specific elements during ashing of the samples prior to the actual instrumental analysis. The results obtained for the hair sample by the two techniques were in good agreement for the elements Co, Fe, Mn, and Zn, but did not agree for the elements Cr and Sb. As, Hg and Se could only be determined with Instrumental Neutron Activation Analysis, and Cd, Cu and Ni only with Atomic Absorption. Most of the results obtained for the three control standard reference materials were within the ranges specified for the individual elements in each sample. The analytical procedures used for determining Cd, Cr, Cu, Ni and Sb with Instrumental Neutron Activation Analysis and As, Cr, Sb and Se with Atomic Absorption, need further investigation. The measurement of the moisture content and the ashing of samples also require further investigation with a view to improving accuracy

  19. Validation of a motor activity system by a robotically controlled vehicle and using standard reference compounds.

    Science.gov (United States)

    Patterson, John P; Markgraf, Carrie G; Cirino, Maria; Bass, Alan S

    2005-01-01

    A series of experiments were undertaken to evaluate the accuracy, precision, specificity, and sensitivity of an automated, infrared photo beam-based open field motor activity system, the MotorMonitor v. 4.01, Hamilton-Kinder, LLC, for use in a good laboratory practices (GLP) Safety Pharmacology laboratory. This evaluation consisted of two phases: (1) system validation, employing known inputs using the EM-100 Controller Photo Beam Validation System, a robotically controlled vehicle representing a rodent and (2) biologic validation, employing groups of rats treated with the standard pharmacologic agents diazepam or D-amphetamine. The MotorMonitor's parameters that described the open-field activity of a subject were: basic movements, total distance, fine movements, x/y horizontal ambulations, rearing, and total rest time. These measurements were evaluated over a number of zones within each enclosure. System validation with the EM-100 Controller Photo Beam Validation System showed that all the parameters accurately and precisely measured what they were intended to measure, with the exception of fine movements and x/y ambulations. Biologic validation using the central nervous system depressant diazepam at 1, 2, or 5 mg/kg, i.p. produced the expected dose-dependent reduction in rat motor activity. In contrast, the central nervous system stimulant D-amphetamine produced the expected increases in rat motor activity at 0.1 and 1 mg/kg, i.p, demonstrating the specificity and sensitivity of the system. Taken together, these studies of the accuracy, precision, specificity, and sensitivity show the importance of both system and biologic validation in the evaluation of an automated open field motor activity system for use in a GLP compliant laboratory.

  20. Reference and standard benchmark field consensus fission yields for U.S. reactor dosimetry programs

    International Nuclear Information System (INIS)

    Gilliam, D.M.; Helmer, R.G.; Greenwood, R.C.; Rogers, J.W.; Heinrich, R.R.; Popek, R.J.; Kellogg, L.S.; Lippincott, E.P.; Hansen, G.E.; Zimmer, W.H.

    1977-01-01

    Measured fission product yields are reported for three benchmark neutron fields--the BIG-10 fast critical assembly at Los Alamos, the CFRMF fast neutron cavity at INEL, and the thermal column of the NBS Research Reactor. These measurements were carried out by participants in the Interlaboratory LMFBR Reaction Rates (ILRR) program. Fission product generation rates were determined by post-irradiation analysis of gamma-ray emission from fission activation foils. The gamma counting was performed by Ge(Li) spectrometry at INEL, ANL, and HEDL; the sample sent to INEL was also analyzed by NaI(Tl) spectrometry for Ba-140 content. The fission rates were determined by means of the NBS Double Fission Ionization Chamber using thin deposits of each of the fissionable isotopes. Four fissionable isotopes were included in the fast neutron field measurements; these were U-235, U-238, Pu-239, and Np-237. Only U-235 was included in the thermal neutron yield measurements. For the fast neutron fields, consensus yields were determined for three fission product isotopes--Zr-95, Ru-103, and Ba-140. For these fission product isotopes, a separately activated foil was analyzed by each of the three gamma counting laboratories. The experimental standard deviation of the three independent results was typically +- 1.5%. For the thermal neutron field, a consensus value for the Cs-137 yield was also obtained. Subsidiary fission yields are also reported for other isotopes which were studied less intensively (usually by only one of the participating laboratories). Comparisons with EBR-II fast reactor yields from destructive analysis and with ENDF/B recommended values are given

  1. Sandia National Laboratories Advanced Simulation and Computing (ASC) software quality plan part 2 mappings for the ASC software quality engineering practices, version 2.0.

    Energy Technology Data Exchange (ETDEWEB)

    Heaphy, Robert; Sturtevant, Judith E.; Hodges, Ann Louise; Boucheron, Edward A.; Drake, Richard Roy; Minana, Molly A.; Hackney, Patricia; Forsythe, Christi A.; Schofield, Joseph Richard, Jr. (,; .); Pavlakos, Constantine James; Williamson, Charles Michael; Edwards, Harold Carter

    2006-09-01

    The purpose of the Sandia National Laboratories Advanced Simulation and Computing (ASC) Software Quality Plan is to clearly identify the practices that are the basis for continually improving the quality of ASC software products. The plan defines the ASC program software quality practices and provides mappings of these practices to Sandia Corporate Requirements CPR001.3.2 and CPR001.3.6 and to a Department of Energy document, ''ASCI Software Quality Engineering: Goals, Principles, and Guidelines''. This document also identifies ASC management and software project teams' responsibilities in implementing the software quality practices and in assessing progress towards achieving their software quality goals.

  2. Biomass-burning derived aromatic acids in NIST standard reference material 1649b and the environmental implications

    Science.gov (United States)

    Gao, Shaopeng; Xu, Baiqing; Dong, Xueling; Zheng, Xiaoyan; Wan, Xin; Kang, Shichang; Song, Qiuyin; Kawamura, Kimitaka; Cong, Zhiyuan

    2018-07-01

    Biomass burning is a serious problem in the environment and climate system. However, the source identification of biomass-burning aerosols was somewhat impeded, partly due to the difficulty in quantification of relevant molecular markers. In this study, we present reference values for five aromatic acids (including p-hydroxybenzoic, vanillic, dehydroabietic, syringic and p-coumaric acids) in the NIST Standard Reference Material (SRM) 1649b. The concentration of levoglucosan was also revisited. Notable positive matrix effect was found for vanillic, dehydroabietic, syringic and coumaric acid. Using the standard addition method, the average value of p-hydroxybenzoic, vanillic, syringic, dehydroabietic and p-coumaric acids in SRM 1649b were found to be 26.9, 9.53, 1.13, 7.60 and 1.66 μg g-1, respectively. The analytical method developed in this study was also applied to the PM10 samples from Beijing and PM2.5 samples from South Asia (Godavari, Nepal). The ratios of vanillic to p-hydroxybenzoic acid and syringic to vanillic acid further suggested that their biomass-burning types are mainly related to hard wood and herbaceous species (i.e., agricultural residues).

  3. New reference charts for testicular volume in Dutch children and adolescents allow the calculation of standard deviation scores.

    Science.gov (United States)

    Joustra, Sjoerd D; van der Plas, Evelyn M; Goede, Joery; Oostdijk, Wilma; Delemarre-van de Waal, Henriette A; Hack, Wilfried W M; van Buuren, Stef; Wit, Jan M

    2015-06-01

    Accurate calculations of testicular volume standard deviation (SD) scores are not currently available. We constructed LMS-smoothed age-reference charts for testicular volume in healthy boys. The LMS method was used to calculate reference data, based on testicular volumes from ultrasonography and Prader orchidometer of 769 healthy Dutch boys aged 6 months to 19 years. We also explored the association between testicular growth and pubic hair development, and data were compared to orchidometric testicular volumes from the 1997 Dutch nationwide growth study. The LMS-smoothed reference charts showed that no revision of the definition of normal onset of male puberty - from nine to 14 years of age - was warranted. In healthy boys, the pubic hair stage SD scores corresponded with testicular volume SD scores (r = 0.394). However, testes were relatively small for pubic hair stage in Klinefelter's syndrome and relatively large in immunoglobulin superfamily member 1 deficiency syndrome. The age-corrected SD scores for testicular volume will aid in the diagnosis and follow-up of abnormalities in the timing and progression of male puberty and in research evaluations. The SD scores can be compared with pubic hair SD scores to identify discrepancies between cell functions that result in relative microorchidism or macroorchidism. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  4. Consequences of new reference climate years according to the Dutch standard NEN 5060; Gevolgen nieuwe referentieklimaatjaren volgens NEN 5060

    Energy Technology Data Exchange (ETDEWEB)

    Hooft, E.N. ' t [Grontmij, Amersfoort (Netherlands)

    2009-02-15

    Because of the climate changes the reference year 1964-1965 is a topic of discussion as on appropriate climate file for the design of climate installations. Therefor, in the Netherlands, new climate reference years are developed for temperature and energy calculations, outlined in the Dutch standard NEN 5060 (Hygrothermal properties of buildings. Reference climate data). This article shows for a nursing home the consequences on the design, energy consumption and energy costs of the climate installation. [Dutch] Vanwege de klimaatveranderingen, die een duidelijke trend naar warmere jaren laat zien, staat het referentiejaar 1964-1965 ter discussie als geschikt klimaatbestand voor bet ontwerp van klimaatinstallaties. Om die reden zijn voor Nederland nieuwe referentieklimaatjaren ontwikkeld voor temperatuur- en energieberekeningen, die zijn opgenomen in NEN 5060 (Hygro-thermische eigenschappen van gebouwen. Referentieklimaatgegevens), die als definitieve versie is verschenen. Dit artikel laat aan de hand van een rekenstudie aan een referentiegebouw in de gezondheidszorg (verpleeghuis) zien wat de consequenties zijn van de nieuw ontwikkelde referentieklimaatjaren op bet ontwerp, het energiegebruik en de energiekosten van de klimaatinstallatie.

  5. Sandia National Laboratories Advanced Simulation and Computing (ASC) software quality plan. Part 1 : ASC software quality engineering practices version 1.0.

    Energy Technology Data Exchange (ETDEWEB)

    Minana, Molly A.; Sturtevant, Judith E.; Heaphy, Robert; Hodges, Ann Louise; Boucheron, Edward A.; Drake, Richard Roy; Forsythe, Christi A.; Schofield, Joseph Richard, Jr.; Pavlakos, Constantine James; Williamson, Charles Michael; Edwards, Harold Carter

    2005-01-01

    The purpose of the Sandia National Laboratories (SNL) Advanced Simulation and Computing (ASC) Software Quality Plan is to clearly identify the practices that are the basis for continually improving the quality of ASC software products. Quality is defined in DOE/AL Quality Criteria (QC-1) as conformance to customer requirements and expectations. This quality plan defines the ASC program software quality practices and provides mappings of these practices to the SNL Corporate Process Requirements (CPR 1.3.2 and CPR 1.3.6) and the Department of Energy (DOE) document, ASCI Software Quality Engineering: Goals, Principles, and Guidelines (GP&G). This quality plan identifies ASC management and software project teams' responsibilities for cost-effective software engineering quality practices. The SNL ASC Software Quality Plan establishes the signatories commitment to improving software products by applying cost-effective software engineering quality practices. This document explains the project teams opportunities for tailoring and implementing the practices; enumerates the practices that compose the development of SNL ASC's software products; and includes a sample assessment checklist that was developed based upon the practices in this document.

  6. FY17 ASC CSSE L2 Milestone 6018: Power Usage Characteristics of Workloads Running on Trinity.

    Energy Technology Data Exchange (ETDEWEB)

    Pedretti, Kevin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-09-01

    The overall goal of this work was to utilize the Advanced Power Management (APM) capabilities of the ATS-1 Trinity platform to understand the power usage behavior of ASC workloads running on Trinity and gain insight into the potential for utilizing power management techniques on future ASC platforms.

  7. Determination of caffeine, theobromine, and theophylline in standard reference material 2384, baking chocolate, using reversed-phase liquid chromatography.

    Science.gov (United States)

    Thomas, Jeanice Brown; Yen, James H; Schantz, Michele M; Porter, Barbara J; Sharpless, Katherine E

    2004-06-02

    A rapid and selective isocratic reversed-phase liquid chromatographic method has been developed at the National Institute of Standards and Technology to simultaneously measure caffeine, theobromine, and theophylline in a food-matrix standard reference material (SRM) 2384, Baking Chocolate. The method uses isocratic elution with a mobile phase composition (volume fractions) of 10% acetronitrile/90% water (pH adjusted to 2.5 using acetic acid) at a flow rate of 1.5 mL/min with ultraviolet absorbance detection (274 nm). Total elution time for these analytes is less than 15 min. Concentration levels of caffeine, theobromine, and theophylline were measured in single 1-g samples taken from each of eight bars of chocolate over an eight-day period. Samples were defatted with hexane, and beta-hydroxyethyltheophylline was added as the internal standard. The repeatability for the caffeine, theobromine, and theophylline measurements was 5.1, 2.3, and 1.9%, respectively. The limit of quantitation for all analytes was theobromine, and theophylline in SRM 2384.

  8. NEURO-SYSTEM OF AIMING AND STABILIZING WITH A REGULATOR ON THE BASIS OF STANDARD MODEL MODEL REFERENCE CONTROLLER

    Directory of Open Access Journals (Sweden)

    B.I. Kuznetsov

    2015-08-01

    Full Text Available The aim of this work is the synthesis of neural network aiming and stabilization system for the special equipment of moving objects with neuro-controller on the basis of standard model and performance comparison of the neural network system with the neural network predictive control. Build a block diagram of the neural network aiming and stabilization system, based on the subject control principle with PD-regulator in the position loop and with neuro-controller on the basis of standard model in the in the velocity loop. The neuro-controller on the basis of standard model Model Reference Controller is synthesized in the MATLAB Neural Network Toolbox and system simulation is performed. The studies show that the transient state variables of the system are oscillatory. Therefore, the neuro-controller with the prediction NN Predictive Controller should be used for aiming and stabilizing system to provide high dynamic characteristics achieved at the cost of higher complexity and computational cost.

  9. Benefits of a Pharmacology Antimalarial Reference Standard and Proficiency Testing Program Provided by the Worldwide Antimalarial Resistance Network (WWARN)

    Science.gov (United States)

    Lourens, Chris; Lindegardh, Niklas; Barnes, Karen I.; Guerin, Philippe J.; Sibley, Carol H.; White, Nicholas J.

    2014-01-01

    Comprehensive assessment of antimalarial drug resistance should include measurements of antimalarial blood or plasma concentrations in clinical trials and in individual assessments of treatment failure so that true resistance can be differentiated from inadequate drug exposure. Pharmacometric modeling is necessary to assess pharmacokinetic-pharmacodynamic relationships in different populations to optimize dosing. To accomplish both effectively and to allow comparison of data from different laboratories, it is essential that drug concentration measurement is accurate. Proficiency testing (PT) of laboratory procedures is necessary for verification of assay results. Within the Worldwide Antimalarial Resistance Network (WWARN), the goal of the quality assurance/quality control (QA/QC) program is to facilitate and sustain high-quality antimalarial assays. The QA/QC program consists of an international PT program for pharmacology laboratories and a reference material (RM) program for the provision of antimalarial drug standards, metabolites, and internal standards for laboratory use. The RM program currently distributes accurately weighed quantities of antimalarial drug standards, metabolites, and internal standards to 44 pharmacology, in vitro, and drug quality testing laboratories. The pharmacology PT program has sent samples to eight laboratories in four rounds of testing. WWARN technical experts have provided advice for correcting identified problems to improve performance of subsequent analysis and ultimately improved the quality of data. Many participants have demonstrated substantial improvements over subsequent rounds of PT. The WWARN QA/QC program has improved the quality and value of antimalarial drug measurement in laboratories globally. It is a model that has potential to be applied to strengthening laboratories more widely and improving the therapeutics of other infectious diseases. PMID:24777099

  10. Practical utilization of recombinant AAV vector reference standards: focus on vector genomes titration by free ITR qPCR

    Directory of Open Access Journals (Sweden)

    Susan D'Costa

    2016-01-01

    Full Text Available Clinical trials using recombinant adeno-associated virus (rAAV vectors have demonstrated efficacy and a good safety profile. Although the field is advancing quickly, vector analytics and harmonization of dosage units are still a limitation for commercialization. AAV reference standard materials (RSMs can help ensure product safety by controlling the consistency of assays used to characterize rAAV stocks. The most widely utilized unit of vector dosing is based on the encapsidated vector genome. Quantitative polymerase chain reaction (qPCR is now the most common method to titer vector genomes (vg; however, significant inter- and intralaboratory variations have been documented using this technique. Here, RSMs and rAAV stocks were titered on the basis of an inverted terminal repeats (ITRs sequence-specific qPCR and we found an artificial increase in vg titers using a widely utilized approach. The PCR error was introduced by using single-cut linearized plasmid as the standard curve. This bias was eliminated using plasmid standards linearized just outside the ITR region on each end to facilitate the melting of the palindromic ITR sequences during PCR. This new “Free-ITR” qPCR delivers vg titers that are consistent with titers obtained with transgene-specific qPCR and could be used to normalize in-house product-specific AAV vector standards and controls to the rAAV RSMs. The free-ITR method, including well-characterized controls, will help to calibrate doses to compare preclinical and clinical data in the field.

  11. Practical utilization of recombinant AAV vector reference standards: focus on vector genomes titration by free ITR qPCR.

    Science.gov (United States)

    D'Costa, Susan; Blouin, Veronique; Broucque, Frederic; Penaud-Budloo, Magalie; François, Achille; Perez, Irene C; Le Bec, Christine; Moullier, Philippe; Snyder, Richard O; Ayuso, Eduard

    2016-01-01

    Clinical trials using recombinant adeno-associated virus (rAAV) vectors have demonstrated efficacy and a good safety profile. Although the field is advancing quickly, vector analytics and harmonization of dosage units are still a limitation for commercialization. AAV reference standard materials (RSMs) can help ensure product safety by controlling the consistency of assays used to characterize rAAV stocks. The most widely utilized unit of vector dosing is based on the encapsidated vector genome. Quantitative polymerase chain reaction (qPCR) is now the most common method to titer vector genomes (vg); however, significant inter- and intralaboratory variations have been documented using this technique. Here, RSMs and rAAV stocks were titered on the basis of an inverted terminal repeats (ITRs) sequence-specific qPCR and we found an artificial increase in vg titers using a widely utilized approach. The PCR error was introduced by using single-cut linearized plasmid as the standard curve. This bias was eliminated using plasmid standards linearized just outside the ITR region on each end to facilitate the melting of the palindromic ITR sequences during PCR. This new "Free-ITR" qPCR delivers vg titers that are consistent with titers obtained with transgene-specific qPCR and could be used to normalize in-house product-specific AAV vector standards and controls to the rAAV RSMs. The free-ITR method, including well-characterized controls, will help to calibrate doses to compare preclinical and clinical data in the field.

  12. An open source, 3D printed preclinical MRI phantom for repeated measures of contrast agents and reference standards.

    Science.gov (United States)

    Cox, B L; Ludwig, K D; Adamson, E B; Eliceiri, K W; Fain, S B

    2018-03-01

    In medical imaging, clinicians, researchers and technicians have begun to use 3D printing to create specialized phantoms to replace commercial ones due to their customizable and iterative nature. Presented here is the design of a 3D printed open source, reusable magnetic resonance imaging (MRI) phantom, capable of flood-filling, with removable samples for measurements of contrast agent solutions and reference standards, and for use in evaluating acquisition techniques and image reconstruction performance. The phantom was designed using SolidWorks, a computer-aided design software package. The phantom consists of custom and off-the-shelf parts and incorporates an air hole and Luer Lock system to aid in flood filling, a marker for orientation of samples in the filled mode and bolt and tube holes for assembly. The cost of construction for all materials is under $90. All design files are open-source and available for download. To demonstrate utility, B 0 field mapping was performed using a series of gadolinium concentrations in both the unfilled and flood-filled mode. An excellent linear agreement (R 2 >0.998) was observed between measured relaxation rates (R 1 /R 2 ) and gadolinium concentration. The phantom provides a reliable setup to test data acquisition and reconstruction methods and verify physical alignment in alternative nuclei MRI techniques (e.g. carbon-13 and fluorine-19 MRI). A cost-effective, open-source MRI phantom design for repeated quantitative measurement of contrast agents and reference standards in preclinical research is presented. Specifically, the work is an example of how the emerging technology of 3D printing improves flexibility and access for custom phantom design.

  13. Evaluation of new geological reference materials for uranium-series measurements: Chinese Geological Standard Glasses (CGSG) and macusanite obsidian.

    Science.gov (United States)

    Denton, J S; Murrell, M T; Goldstein, S J; Nunn, A J; Amato, R S; Hinrichs, K A

    2013-10-15

    Recent advances in high-resolution, rapid, in situ microanalytical techniques present numerous opportunities for the analytical community, provided accurately characterized reference materials are available. Here, we present multicollector thermal ionization mass spectrometry (MC-TIMS) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) uranium and thorium concentration and isotopic data obtained by isotope dilution for a suite of newly available Chinese Geological Standard Glasses (CGSG) designed for microanalysis. These glasses exhibit a range of compositions including basalt, syenite, andesite, and a soil. Uranium concentrations for these glasses range from ∼2 to 14 μg g(-1), Th/U weight ratios range from ∼4 to 6, (234)U/(238)U activity ratios range from 0.93 to 1.02, and (230)Th/(238)U activity ratios range from 0.98 to 1.12. Uranium and thorium concentration and isotopic data are also presented for a rhyolitic obsidian from Macusani, SE Peru (macusanite). This glass can also be used as a rhyolitic reference material, has a very low Th/U weight ratio (around 0.077), and is approximately in (238)U-(234)U-(230)Th secular equilibrium. The U-Th concentration data agree with but are significantly more precise than those previously measured. U-Th concentration and isotopic data agree within estimated errors for the two measurement techniques, providing validation of the two methods. The large (238)U-(234)U-(230)Th disequilibria for some of the glasses, along with the wide range in their chemical compositions and Th/U ratios should provide useful reference points for the U-series analytical community.

  14. Development of the neutron reference calibration field using a {sup 252}Cf standard source surrounded with PMMA moderators

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, T.; Kanai, K.; Tsujimura, N. [Japan Nuclear Cycle Development Institute, Ibaraki-ken (Japan)

    2002-07-01

    The authors developed the neutron reference calibration fields using a {sup 252} Cf standard source surrounded with PMMA moderators at the Japan Nuclear Cycle Development (JNC), Tokai Works. The moderators are co-axial, hollow cylinders made of lead-contained PMMA with a thickness of 13.5, 35.0, 59.5 and 77.0mm, and the {sup 252} Cf source is guided to the geometric center of moderators by the pneumatic system. These fields can provide the moderated neutron spectra very similar to those encountered around the globe-boxes of the fabrication process of MOX (PuO{sub 2}-UO{sub 2} mixed oxide) fuel. The neutron energy spectrum at the reference calibration point was evaluated from the calculations by MCNP4B and the measurements by the INS-type Bonner multi-sphere spectrometer and the hydrogen-filled proportional counters. The calculated neutron spectra were in good agreements with the measured ones. These fields were characterized in terms of the neutron fluence rate, spectral composition and ambient dose equivalent rate, and have served for the response-characterization of various neutron survey instruments.

  15. Development of the neutron reference calibration field using a 252Cf standard source surrounded with PMMA moderators

    International Nuclear Information System (INIS)

    Yoshida, T.; Kanai, K.; Tsujimura, N.

    2002-01-01

    The authors developed the neutron reference calibration fields using a 252 Cf standard source surrounded with PMMA moderators at the Japan Nuclear Cycle Development (JNC), Tokai Works. The moderators are co-axial, hollow cylinders made of lead-contained PMMA with a thickness of 13.5, 35.0, 59.5 and 77.0mm, and the 252 Cf source is guided to the geometric center of moderators by the pneumatic system. These fields can provide the moderated neutron spectra very similar to those encountered around the globe-boxes of the fabrication process of MOX (PuO 2 -UO 2 mixed oxide) fuel. The neutron energy spectrum at the reference calibration point was evaluated from the calculations by MCNP4B and the measurements by the INS-type Bonner multi-sphere spectrometer and the hydrogen-filled proportional counters. The calculated neutron spectra were in good agreements with the measured ones. These fields were characterized in terms of the neutron fluence rate, spectral composition and ambient dose equivalent rate, and have served for the response-characterization of various neutron survey instruments

  16. Standardization of glycohemoglobin results and reference values in whole blood studied in 103 laboratories using 20 methods.

    Science.gov (United States)

    Weykamp, C W; Penders, T J; Miedema, K; Muskiet, F A; van der Slik, W

    1995-01-01

    We investigated the effect of calibration with lyophilized calibrators on whole-blood glycohemoglobin (glyHb) results. One hundred three laboratories, using 20 different methods, determined glyHb in two lyophilized calibrators and two whole-blood samples. For whole-blood samples with low (5%) and high (9%) glyHb percentages, respectively, calibration decreased overall interlaboratory variation (CV) from 16% to 9% and from 11% to 6% and decreased intermethod variation from 14% to 6% and from 12% to 5%. Forty-seven laboratories, using 14 different methods, determined mean glyHb percentages in self-selected groups of 10 nondiabetic volunteers each. With calibration their overall mean (2SD) was 5.0% (0.5%), very close to the 5.0% (0.3%) derived from the reference method used in the Diabetes Control and Complications Trial. In both experiments the Abbott IMx and Vision showed deviating results. We conclude that, irrespective of the analytical method used, calibration enables standardization of glyHb results, reference values, and interpretation criteria.

  17. Solid phase speciation of arsenic by sequential extraction in standard reference materials and industrially contaminated soil samples

    International Nuclear Information System (INIS)

    Herreweghe, Samuel van; Swennen, Rudy; Vandecasteele, Carlo; Cappuyns, Valerie

    2003-01-01

    Leaching experiments, a mineralogical survey and larger samples are preferred when arsenic is present as discrete mineral phases. - Availability, mobility, (phyto)toxicity and potential risk of contaminants is strongly affected by the manner of appearance of elements, the so-called speciation. Operational fractionation methods like sequential extractions have been applied for a long time to determine the solid phase speciation of heavy metals since direct determination of specific chemical compounds can not always be easily achieved. The three-step sequential extraction scheme recommended by the BCR and two extraction schemes based on the phosphorus-like protocol proposed by Manful (1992, Occurrence and Ecochemical Behaviours of Arsenic in a Goldsmelter Impacted Area in Ghana, PhD dissertation, at the RUG) were applied to four standard reference materials (SRM) and to a batch of samples from industrially contaminated sites, heavily contaminated with arsenic and heavy metals. The SRM 2710 (Montana soil) was found to be the most useful reference material for metal (Mn, Cu, Zn, As, Cd and Pb) fractionation using the BCR sequential extraction procedure. Two sequential extraction schemes were developed and compared for arsenic with the aim to establish a better fractionation and recovery rate than the BCR-scheme for this element in the SRM samples. The major part of arsenic was released from the heavily contaminated samples after NaOH-extraction. Inferior extraction variability and recovery in the heavily contaminated samples compared to SRMs could be mainly contributed to subsample heterogeneity

  18. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the PTB and the BIPM

    International Nuclear Information System (INIS)

    Kessler, C.; Allisy-Roberts, P.J.; Selbach, H.J.

    2015-01-01

    An indirect comparison of the standards for reference air kerma rate (RAKR) for 192 Ir high dose rate (HDR) brachytherapy sources of the Physikalisch-Technische Bundesanstalt (PTB), Germany, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the PTB in September 2011. The comparison result, based on the calibration coefficients for a transfer standard and expressed as a ratio of the PTB and the BIPM standards for reference air kerma rate, is 1.0003 with a combined standard uncertainty of 0.0099. (authors)

  19. Differential splicing of the apoptosis-associated speck like protein containing a caspase recruitment domain (ASC regulates inflammasomes

    Directory of Open Access Journals (Sweden)

    Rojanasakul Yon

    2010-05-01

    Full Text Available Abstract Background The apoptotic speck-like protein containing a caspase recruitment domain (ASC is the essential adaptor protein for caspase 1 mediated interleukin (IL-1β and IL-18 processing in inflammasomes. It bridges activated Nod like receptors (NLRs, which are a family of cytosolic pattern recognition receptors of the innate immune system, with caspase 1, resulting in caspase 1 activation and subsequent processing of caspase 1 substrates. Hence, macrophages from ASC deficient mice are impaired in their ability to produce bioactive IL-1β. Furthermore, we recently showed that ASC translocates from the nucleus to the cytosol in response to inflammatory stimulation in order to promote an inflammasome response, which triggers IL-1β processing and secretion. However, the precise regulation of inflammasomes at the level of ASC is still not completely understood. In this study we identified and characterized three novel ASC isoforms for their ability to function as an inflammasome adaptor. Methods To establish the ability of ASC and ASC isoforms as functional inflammasome adaptors, IL-1β processing and secretion was investigated by ELISA in inflammasome reconstitution assays, stable expression in THP-1 and J774A1 cells, and by restoring the lack of endogenous ASC in mouse RAW264.7 macrophages. In addition, the localization of ASC and ASC isoforms was determined by immunofluorescence staining. Results The three novel ASC isoforms, ASC-b, ASC-c and ASC-d display unique and distinct capabilities to each other and to full length ASC in respect to their function as an inflammasome adaptor, with one of the isoforms even showing an inhibitory effect. Consistently, only the activating isoforms of ASC, ASC and ASC-b, co-localized with NLRP3 and caspase 1, while the inhibitory isoform ASC-c, co-localized only with caspase 1, but not with NLRP3. ASC-d did not co-localize with NLRP3 or with caspase 1 and consistently lacked the ability to function as an

  20. Reference News Release: U.S. Files Complaint, Announces Settlement to Address Alleged Renewable Fuel Standard Violations by NGL Crude Logistics and Western Dubuque Biodiesel

    Science.gov (United States)

    Reference news release on the complaint against NGL Crude Logistics, LLC and Western Dubuque Biodiesel, LLC and a settlement with Western Dubuque to address alleged violations of the Renewable Fuel Standard.

  1. Global panel of HIV-1 Env reference strains for standardized assessments of vaccine-elicited neutralizing antibodies.

    Science.gov (United States)

    deCamp, Allan; Hraber, Peter; Bailer, Robert T; Seaman, Michael S; Ochsenbauer, Christina; Kappes, John; Gottardo, Raphael; Edlefsen, Paul; Self, Steve; Tang, Haili; Greene, Kelli; Gao, Hongmei; Daniell, Xiaoju; Sarzotti-Kelsoe, Marcella; Gorny, Miroslaw K; Zolla-Pazner, Susan; LaBranche, Celia C; Mascola, John R; Korber, Bette T; Montefiori, David C

    2014-03-01

    Standardized assessments of HIV-1 vaccine-elicited neutralizing antibody responses are complicated by the genetic and antigenic variability of the viral envelope glycoproteins (Envs). To address these issues, suitable reference strains are needed that are representative of the global epidemic. Several panels have been recommended previously, but no clear answers have been available on how many and which strains are best suited for this purpose. We used a statistical model selection method to identify a global panel of reference Env clones from among 219 Env-pseudotyped viruses assayed in TZM-bl cells with sera from 205 HIV-1-infected individuals. The Envs and sera were sampled globally from diverse geographic locations and represented all major genetic subtypes and circulating recombinant forms of the virus. Assays with a panel size of only nine viruses adequately represented the spectrum of HIV-1 serum neutralizing activity seen with the larger panel of 219 viruses. An optimal panel of nine viruses was selected and augmented with three additional viruses for greater genetic and antigenic coverage. The spectrum of HIV-1 serum neutralizing activity seen with the final 12-virus panel closely approximated the activity seen with subtype-matched viruses. Moreover, the final panel was highly sensitive for detection of many of the known broadly neutralizing antibodies. For broader assay applications, all 12 Env clones were converted to infectious molecular clones using a proviral backbone carrying a Renilla luciferase reporter gene (Env.IMC.LucR viruses). This global panel should facilitate highly standardized assessments of vaccine-elicited neutralizing antibodies across multiple HIV-1 vaccine platforms in different parts of the world. An effective HIV-1 vaccine will need to overcome the extraordinary genetic variability of the virus, where most variation occurs in the viral envelope glycoproteins that are the sole targets for neutralizing antibodies. Efforts to elicit

  2. Characterization of the Defense Waste Processing Facility (DWPF) Environmental Assessment (EA) glass Standard Reference Material. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Crawford, C.L.; Pickett, M.A.

    1993-06-01

    Liquid high-level nuclear waste at the Savannah River Site (SRS) will be immobilized by vitrification in borosilicate glass. The glass will be produced and poured into stainless steel canisters in the Defense Waste Processing Facility (DWPF). Other waste form producers, such as West Valley Nuclear Services (WVNS) and the Hanford Waste Vitrification Project (HWVP), will also immobilize high-level radioactive waste in borosilicate glass. The canistered waste will be stored temporarily at each facility for eventual permanent disposal in a geologic repository. The Department of Energy has defined a set of requirements for the canistered waste forms, the Waste Acceptance Product Specifications (WAPS). The current Waste Acceptance Primary Specification (WAPS) 1.3, the product consistency specification, requires the waste form producers to demonstrate control of the consistency of the final waste form using a crushed glass durability test, the Product Consistency Test (PCI). In order to be acceptable, a waste glass must be more durable during PCT analysis than the waste glass identified in the DWPF Environmental Assessment (EA). In order to supply all the waste form producers with the same standard benchmark glass, 1000 pounds of the EA glass was fabricated. The chemical analyses and characterization of the benchmark EA glass are reported. This material is now available to act as a durability and/or redox Standard Reference Material (SRM) for all waste form producers.

  3. Dimorfismo de ascósporos em Glomerella cingulata f.sp. phaseoli

    OpenAIRE

    Castro, Renata A.; Mendes-Costa, Maria C.; Souza, Elaine A.

    2006-01-01

    O objetivo deste trabalho foi caracterizar linhagens de Glomerella cingulata f. sp. phaseoli quanto ao crescimento micelial, formação de peritécio e dimorfismo de ascósporos. Foram avaliadas quatro linhagens nos meios de cultura de folhas de feijoeiro e meio M3 e em condições com e sem fotoperíodo. O comprimento dos ascósporos da linhagem normal e da mutante foi determinado. Houve diferença significativa quanto ao crescimento micelial e tamanho dos ascósporos. Constatou-se, pela primeira vez,...

  4. New Normative Database of Inner Macular Layer Thickness Measured by Spectralis OCT Used as Reference Standard for Glaucoma Detection.

    Science.gov (United States)

    Nieves-Moreno, María; Martínez-de-la-Casa, José M; Bambo, María P; Morales-Fernández, Laura; Van Keer, Karel; Vandewalle, Evelien; Stalmans, Ingeborg; García-Feijoó, Julián

    2018-02-01

    This study examines the capacity to detect glaucoma of inner macular layer thickness measured by spectral-domain optical coherence tomography (SD-OCT) using a new normative database as the reference standard. Participants ( N = 148) were recruited from Leuven (Belgium) and Zaragoza (Spain): 74 patients with early/moderate glaucoma and 74 age-matched healthy controls. One eye was randomly selected for a macular scan using the Spectralis SD-OCT. The variables measured with the instrument's segmentation software were: macular nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) volume and thickness along with circumpapillary RNFL thickness (cpRNFL). The new normative database of macular variables was used to define the cutoff of normality as the fifth percentile by age group. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of each macular measurement and of cpRNFL were used to distinguish between patients and controls. Overall sensitivity and specificity to detect early-moderate glaucoma were 42.2% and 88.9% for mRNFL, 42.4% and 95.6% for GCL, 42.2% and 94.5% for IPL, and 53% and 94.6% for RNFL, respectively. The best macular variable to discriminate between the two groups of subjects was outer temporal GCL thickness as indicated by an AUROC of 0.903. This variable performed similarly to mean cpRNFL thickness (AUROC = 0.845; P = 0.29). Using our normative database as reference, the diagnostic power of inner macular layer thickness proved comparable to that of peripapillary RNFL thickness. Spectralis SD-OCT, cpRNFL thickness, and individual macular inner layer thicknesses show comparable diagnostic capacity for glaucoma and RNFL, GCL, and IPL thickness may be useful as an alternative diagnostic test when the measure of cpRNFL shows artifacts.

  5. Ambulatory Blood Pressure Monitoring (ABPM) as the reference standard for diagnosis of hypertension and assessment of vascular risk in adults.

    Science.gov (United States)

    Hermida, Ramón C; Smolensky, Michael H; Ayala, Diana E; Portaluppi, Francesco

    2015-01-01

    New information has become available since the ISC, AAMCC, and SECAC released their first extensive guidedelines to improve the diagnosis and treatment of adult arterial hypertension. A critical assessment of evidence and a comparison of what international guidelines now propose are the basis for the following statements, which update the recommendations first issued in 2013. Office blood pressure (BP) measurements should no longer be considered to be the "gold standard" for the diagnosis of hypertension and assessment of cardiovascular risk. Relying on office BP, even when supplemented with at-home wake-time self-measurements, to identify high-risk individuals, disregarding circadian BP patterning and asleep BP level, leads to potential misclassification of 50% of all evaluated persons. Accordingly, ambulatory BP monitoring is the recommended reference standard for the diagnosis of true hypertension and accurate assessment of cardiovascular risk in all adults ≥18 yrs of age, regardless of whether office BP is normal or elevated. Asleep systolic BP mean is the most significant independent predictor of cardiovascular events. The sleep-time relative SBP decline adds prognostic value to the statistical model that already includes the asleep systolic BP mean and corrected for relevant confounding variables. Accordingly, the asleep systolic BP mean is the recommended protocol to diagnose hypertension, assess cardiovascular risk, and predict cardiovascular event-free interval. In men, and in the absence of compelling clinical conditions, reference thresholds for diagnosing hypertension are 120/70 mmHg for the asleep systolic/diastolic BP means derived from ambulatory BP monitoring. However, in women, in the absence of complicating co-morbidities, the same thresholds are lower by 10/5 mmHg, i.e., 110/65 mmHg for the asleep means. In high-risk patients, including those diagnosed with diabetes or chronic kidney disease, and/or those having experienced past

  6. Recent applications of nuclear analytical methods to the certification of elemental content in NIST standard reference materials

    International Nuclear Information System (INIS)

    Greenberg, R.R.; Zeisler, R.; Mackey, E.A.

    2006-01-01

    Well-characterized, certified reference materials (CRMs) play an essential role in assuring the quality of analytical measurements. NIST has been producing CRMs, currently called NIST Standard Reference Materials (SRMs), to validate analytical measurements for nearly one hundred years. The predominant mode of certifying inorganic constituents in complex-matrix SRMs is through the use of two critically evaluated, independent analytical techniques at NIST. These techniques should have no significant sources of error in common. The use of nuclear analytical methods in combination with one of the chemically based analytical method at NIST eliminates the possibility of any significant, common error source. The inherent characteristics of the various forms of nuclear analytical methods make them extremely valuable for SRM certification. Instrumental NAA is nondestructive, which eliminates the possibility of any dissolution problems, and often provides homogeneity information. Radiochemical NAA typically provides nearly blank-free determinations of some highly important, but difficult elements at very low levels. Prompt-gamma NAA complements INAA, and provides independent determinations of some key elements. In addition, all significant uncertainty components can be evaluated for these techniques, and we believe these methods can meet all the requirements of a primary method of measurement as defined by ISO and the CCQM. NIST has certified several SRMs using INAA and RNAA as primary methods. In addition, NIST has compared measurements by INAA and PGAA with other primary methods as part of the CCQM intercomparisons of national metrology institutes. Some significant SRMs recently certified for inorganic constituents with contributions from the nuclear analytical methods include: Toxic Substances in Urine (SRM 2670a), Lake Superior Fish Tissue (SRM 1946), Air Particulate on Filter Media (SRM 2783), Inorganics in Marine Sediment (SRM 2702), Sediment for Solid Sampling (Small

  7. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    Science.gov (United States)

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  8. KoVariome: Korean National Standard Reference Variome database of whole genomes with comprehensive SNV, indel, CNV, and SV analyses.

    Science.gov (United States)

    Kim, Jungeun; Weber, Jessica A; Jho, Sungwoong; Jang, Jinho; Jun, JeHoon; Cho, Yun Sung; Kim, Hak-Min; Kim, Hyunho; Kim, Yumi; Chung, OkSung; Kim, Chang Geun; Lee, HyeJin; Kim, Byung Chul; Han, Kyudong; Koh, InSong; Chae, Kyun Shik; Lee, Semin; Edwards, Jeremy S; Bhak, Jong

    2018-04-04

    High-coverage whole-genome sequencing data of a single ethnicity can provide a useful catalogue of population-specific genetic variations, and provides a critical resource that can be used to more accurately identify pathogenic genetic variants. We report a comprehensive analysis of the Korean population, and present the Korean National Standard Reference Variome (KoVariome). As a part of the Korean Personal Genome Project (KPGP), we constructed the KoVariome database using 5.5 terabases of whole genome sequence data from 50 healthy Korean individuals in order to characterize the benign ethnicity-relevant genetic variation present in the Korean population. In total, KoVariome includes 12.7M single-nucleotide variants (SNVs), 1.7M short insertions and deletions (indels), 4K structural variations (SVs), and 3.6K copy number variations (CNVs). Among them, 2.4M (19%) SNVs and 0.4M (24%) indels were identified as novel. We also discovered selective enrichment of 3.8M SNVs and 0.5M indels in Korean individuals, which were used to filter out 1,271 coding-SNVs not originally removed from the 1,000 Genomes Project when prioritizing disease-causing variants. KoVariome health records were used to identify novel disease-causing variants in the Korean population, demonstrating the value of high-quality ethnic variation databases for the accurate interpretation of individual genomes and the precise characterization of genetic variations.

  9. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Maijers, M.C.; Ritt, M.J.P.F. [VU University Medical Centre, Department of Plastic, Reconstructive and Hand Surgery, De Boelelaan 1117, PO Box 7057, Amsterdam (Netherlands); Niessen, F.B. [VU University Medical Centre, Department of Plastic, Reconstructive and Hand Surgery, De Boelelaan 1117, PO Box 7057, Amsterdam (Netherlands); Jan van Goyen Clinic, Department of Plastic Surgery, Amsterdam (Netherlands); Veldhuizen, J.F.H. [MRI Centre, Amsterdam (Netherlands); Manoliu, R.A. [MRI Centre, Amsterdam (Netherlands); VU University Medical Centre, Department of Radiology, Amsterdam (Netherlands)

    2014-06-15

    The recall of Poly Implant Prothese (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. (orig.)

  10. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

    International Nuclear Information System (INIS)

    Maijers, M.C.; Ritt, M.J.P.F.; Niessen, F.B.; Veldhuizen, J.F.H.; Manoliu, R.A.

    2014-01-01

    The recall of Poly Implant Prothese (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. (orig.)

  11. Relation of structure to function for the US reference standard endotoxin after exposure to 60Co radiation

    International Nuclear Information System (INIS)

    Csako, G.; Suba, E.A.; Ahlgren, A.; Tsai, C.M.; Elin, R.J.

    1986-01-01

    The structure and function of the highly purified US reference standard endotoxin (RSE) were studied after exposure to ionizing radiation from a 60 Co source. With increasing doses of radiation, the trilaminar ribbon-like structure of untreated endotoxin exhibited focal swelling, after which only spherical particles were seen by electron microscopy. These morphological changes were paralleled by the respective loss of O-side chain repeating units and pieces of the R-core from the lipopolysaccharide molecules, as demonstrated by electrophoresis. The biologic function of the irradiated endotoxin was assessed with a variety of tests. At higher doses of radiation, a direct relation was observed between the degradation of the molecular and supramolecular structure and the loss of biologic function. At lower doses of radiation, however, there was variability among the functional assays in their rate of change with progressive irradiation of the RSE. The results suggest that the carbohydrate moiety plays an important role both in determining the supramolecular structure and in modulating certain biologic activities of bacterial endotoxins

  12. Lung function in North American Indian children: reference standards for spirometry, maximal expiratory flow volume curves, and peak expiratory flow.

    Science.gov (United States)

    Wall, M A; Olson, D; Bonn, B A; Creelman, T; Buist, A S

    1982-02-01

    Reference standards of lung function was determined in 176 healthy North American Indian children (94 girls, 82 boys) 7 to 18 yr of age. Spirometry, maximal expiratory flow volume curves, and peak expiratory flow rate were measured using techniques and equipment recommended by the American Thoracic Society. Standing height was found to be an accurate predictor of lung function, and prediction equations for each lung function variable are presented using standing height as the independent variable. Lung volumes and expiratory flow rates in North American Indian children were similar to those previously reported for white and Mexican-American children but were greater than those in black children. In both boys and girls, lung function increased in a curvilinear fashion. Volume-adjusted maximal expiratory flow rates after expiring 50 or 75% of FVC tended to decrease in both sexes as age and height increased. Our maximal expiratory flow volume curve data suggest that as North American Indian children grow, lung volume increases at a slightly faster rate than airway size does.

  13. Determination of reference intervals and comparison of venous blood gas parameters using standard and non-standard collection methods in 24 cats.

    Science.gov (United States)

    Bachmann, Karin; Kutter, Annette Pn; Schefer, Rahel Jud; Marly-Voquer, Charlotte; Sigrist, Nadja

    2017-08-01

    Objectives The aim of this study was to determine in-house reference intervals (RIs) for venous blood analysis with the RAPIDPoint 500 blood gas analyser using blood gas syringes (BGSs) and to determine whether immediate analysis of venous blood collected into lithium heparin (LH) tubes can replace anaerobic blood sampling into BGSs. Methods Venous blood was collected from 24 healthy cats and directly transferred into a BGS and an LH tube. The BGS was immediately analysed on the RAPIDPoint 500 followed by the LH tube. The BGSs and LH tubes were compared using paired t-test or Wilcoxon matched-pairs signed-rank test, Bland-Altman and Passing-Bablok analysis. To assess clinical relevance, bias or percentage bias between BGSs and LH tubes was compared with the allowable total error (TEa) recommended for the respective parameter. Results Based on the values obtained from the BGSs, RIs were calculated for the evaluated parameters, including blood gases, electrolytes, glucose and lactate. Values derived from LH tubes showed no significant difference for standard bicarbonate, whole blood base excess, haematocrit, total haemoglobin, sodium, potassium, chloride, glucose and lactate, while pH, partial pressure of carbon dioxide and oxygen, actual bicarbonate, extracellular base excess, ionised calcium and anion gap were significantly different to the samples collected in BGSs ( P glucose and lactate can be made based on blood collected in LH tubes and analysed within 5 mins. For pH, partial pressure of carbon dioxide and oxygen, extracellular base excess, anion gap and ionised calcium the clinically relevant alterations have to be considered if analysed in LH tubes.

  14. Factors Affecting Innovation Within Aeronautical Systems Center (ASC) Organizations - An inductive Study

    National Research Council Canada - National Science Library

    Feil, Eric

    2003-01-01

    .... This thesis analyzed data collected during the 2002 Chief of Staff of the Air Force Organizational Climate Survey to identify factors that affect innovation within Aeronautical Systems Center (ASC) organizations...

  15. Aeroacoustics research in Europe : the CEAS-ASC report on 2007 highlights

    NARCIS (Netherlands)

    Brouwer, H.H.; Rienstra, S.W.

    2008-01-01

    The Council of European Aerospace Societies (CEAS) Aeroacoustics Specialists Committee (ASC) supports and promotes the interests of the scientific and industrial aeroacoustics community on a European scale and European aeronautics activities internationally. In this context, "aeroacoustics"

  16. Standard Test Method for Calibration of Primary Non-Concentrator Terrestrial Photovoltaic Reference Cells Using a Tabular Spectrum

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method is intended to be used for calibration and characterization of primary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution, such as Tables G173. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of photovoltaic devices. 1.2 Primary photovoltaic reference cells are calibrated in natural sunlight using the relative spectral response of the cell, the relative spectral distribution of the sunlight, and a tabulated reference spectral irradiance distribution. 1.3 This test method requires the use of a pyrheliometer that is calibrated according to Test Method E816, which requires the use of a pyrheliometer that is traceable to the World Radiometric Reference (WRR). Therefore, reference cells calibrated according to this test method are traceable to the WRR. 1.4 This test method is a technique that may be used ...

  17. Absence of the inflammasome adaptor ASC reduces hypoxia-induced pulmonary hypertension in mice.

    Science.gov (United States)

    Cero, Fadila Telarevic; Hillestad, Vigdis; Sjaastad, Ivar; Yndestad, Arne; Aukrust, Pål; Ranheim, Trine; Lunde, Ida Gjervold; Olsen, Maria Belland; Lien, Egil; Zhang, Lili; Haugstad, Solveig Bjærum; Løberg, Else Marit; Christensen, Geir; Larsen, Karl-Otto; Skjønsberg, Ole Henning

    2015-08-15

    Pulmonary hypertension is a serious condition that can lead to premature death. The mechanisms involved are incompletely understood although a role for the immune system has been suggested. Inflammasomes are part of the innate immune system and consist of the effector caspase-1 and a receptor, where nucleotide-binding oligomerization domain-like receptor pyrin domain-containing 3 (NLRP3) is the best characterized and interacts with the adaptor protein apoptosis-associated speck-like protein containing a caspase-recruitment domain (ASC). To investigate whether ASC and NLRP3 inflammasome components are involved in hypoxia-induced pulmonary hypertension, we utilized mice deficient in ASC and NLRP3. Active caspase-1, IL-18, and IL-1β, which are regulated by inflammasomes, were measured in lung homogenates in wild-type (WT), ASC(-/-), and NLRP3(-/-) mice, and phenotypical changes related to pulmonary hypertension and right ventricular remodeling were characterized after hypoxic exposure. Right ventricular systolic pressure (RVSP) of ASC(-/-) mice was significantly lower than in WT exposed to hypoxia (40.8 ± 1.5 mmHg vs. 55.8 ± 2.4 mmHg, P right ventricular remodeling. RVSP of NLRP3(-/-) mice exposed to hypoxia was not significantly altered compared with WT hypoxia. Whereas hypoxia increased protein levels of caspase-1, IL-18, and IL-1β in WT and NLRP3(-/-) mice, this response was absent in ASC(-/-) mice. Moreover, ASC(-/-) mice displayed reduced muscularization and collagen deposition around arteries. In conclusion, hypoxia-induced elevated right ventricular pressure and remodeling were attenuated in mice lacking the inflammasome adaptor protein ASC, suggesting that inflammasomes play an important role in the pathogenesis of pulmonary hypertension. Copyright © 2015 the American Physiological Society.

  18. Catalogue of EDF`s technical specifications (HN reference). Centre of standardization; Catalogue des specifications techniques EDF (reference HN). Centre de normalisation

    Energy Technology Data Exchange (ETDEWEB)

    1998-12-31

    This document edited by Electricite de France (EdF), is a catalogue of the French standard documents relative to any type of electrical material and equipment and which contain the technical specifications of these materials and equipments. A brief description of these specifications is given for each type of material or equipment listed. (J.S.)

  19. Diagnostic accuracy of direct ophthalmoscopy for detection of diabetic retinopathy using fundus photographs as a reference standard.

    Science.gov (United States)

    Ahsan, Shahid; Basit, Abdul; Ahmed, Kazi Rumana; Ali, Liaquat; Shaheen, Fariha; Ulhaque, Muhammad Saif; Fawwad, Asher

    2014-01-01

    To determine the diagnostic accuracy of direct ophthalmoscopy for the presence and severity of diabetic retinopathy (DR) using fundus photographs as a reference standard. Patients with type 2 diabetes attending the outpatient department (OPD) of a tertiary care diabetes center, from October 2009 to March 2010 were recruited in the study after obtaining signed informed consent. Patients with type 1 diabetes and gestational diabetes or having eye problems were excluded. After checking visual acuity, direct ophthalmoscopy of each eye was done by diabetologist, followed by photography of two fields of retina by fundus camera. DR was graded by a retinal specialist, according to International Diabetic Retinopathy Disease Severity Scale. According to severity, patients with DR were grouped into non-sight threatening diabetic retinopathy (NSTDR) and sight threatening diabetic retinopathy (STDR). Sensitivity and specificity of direct ophthalmoscopy for detection of any retinopathy, NSTDR and STDR was calculated. A total of 728 eyes were examined by direct ophthalmoscopy as well as fundus photography. Sensitivity (95% CI) of direct ophthalmoscopy for any retinopathy, NSTDR and STDR was found to be 55.67% (50.58-60.78), 37.63% (32.67-42.59) and 68.25% (63.48-73.02) respectively. Whereas, specificity of direct ophthalmoscopy was found to be 76.78% (72.45-81.11), 71.27% (CI: 66.63-75.91) and 90.0% (86.93-93.07) for any retinopathy, NSTDR and STDR respectively. The sensitivity and specificity of direct ophthalmoscopy performed by the diabetologist for the presence and severity of DR was lower compared to the recommended level of sensitivity and specificity of a screening test of DR. Copyright © 2014 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  20. A laboratory study on formation of oil-SPM aggregates using the NIST standard reference material 1941b. Volume 1

    International Nuclear Information System (INIS)

    Khelifa, A.; Fieldhouse, B.; Wang, Z.; Yang, C.; Landriault, M.; Fingas, M.; Brown, C.E.; Gamble, L.; Pjontek, D.

    2007-01-01

    The dispersion of spilled oil in water can be enhanced by a natural process in which suspended particulate matter (SPM) combines with oil droplets to form Oil-SPM aggregates (OSA). A laboratory setup and procedure were developed in this study to examine the formation of OSAs in which the sediment (Standard Reference Material 1941b) was mixed with Arabian Medium, Alaska North Slope and South Louisiana crudes at concentrations varying from 25 to 300 mg/L. The OSAs were separated from the bulk water using a newly developed procedure. Gas chromatography combined with flame ionization analysis was used to measure the oil trapped in the OSAs. The sediment trapped in the sinking OSAs was then isolated for gravimetric quantification. This procedure has the potential to isolate sinking OSAs with minimum alteration with dispersed oil. Oil mass of less than 2 mg trapped in OSAs was measured with 0.8 mg uncertainty at a 95 per cent confidence level. This setup was capable of imaging droplets of 0.1 μg and up in size. The study showed that formation of sinking OSAs reaches maximum efficiency at an optimum oil to sediment ratio that decreases from 0.5 to approximately 0.1 when the ratio between oil density and the water density increases from 0.84 to 0.97. The percentage of oil trapped in sinking OSAs increases quickly from approximately 0.5 per cent to 30 per cent of the initial oil mass when sediment concentration increases from 25 to 100 mg/l. The highest trapping efficiency was found to decrease exponentially with oil density. 33 refs., 2 tabs., 12 figs

  1. A comparative uncertainty study of the calibration of macrolide antibiotic reference standards using quantitative nuclear magnetic resonance and mass balance methods

    International Nuclear Information System (INIS)

    Liu Shuyu; Hu Changqin

    2007-01-01

    This study introduces the general method of quantitative nuclear magnetic resonance (qNMR) for the calibration of reference standards of macrolide antibiotics. Several qNMR experimental conditions were optimized including delay, which is an important parameter of quantification. Three kinds of macrolide antibiotics were used to validate the accuracy of the qNMR method by comparison with the results obtained by the high performance liquid chromatography (HPLC) method. The purities of five common reference standards of macrolide antibiotics were measured by the 1 H qNMR method and the mass balance method, respectively. The analysis results of the two methods were compared. The qNMR is quick and simple to use. In a new medicine research and development process, qNMR provides a new and reliable method for purity analysis of the reference standard

  2. Immunocytoexpression profile of ProExC in smears interpreted as ASC-US, ASC-H, and cervical intraepithelial lesion

    Directory of Open Access Journals (Sweden)

    Zeynep Tosuner

    2017-01-01

    Full Text Available Aims: We aimed to investigate the immunocytoexpression profiles of a novel assay ProEx C for topoisomerase II alpha (TOP2A and minichromosome maintenance protein 2 (MCM2 in abnormal interpreted smears. Settings and Design: Screening programs with Papanicolaou smear and high risk group human papilloma virus testing have yielded a dramatic reduction of cervical cancer incidence. However, both of these tests have limited specificity for the detection of clinically significant cervical high grade lesions. ProEx C for topoisomerase II alpha (TOP2A and minichromosome maintenance protein 2 (MCM2 has been considered to have tight association with high grade intraepithelial lesions. Materials and Methods: A total number of 54 SurePath cervical cytology specimens of patients previously interpreted as atypical squamous cells-undetermined significance (ASC-US, atypical squamous cells-cannot exclude high grade squamous intraepithelial lesion (ASC-H, low grade squamous intraepithelial lesion (LSIL, and high grade squamous intraepithelial lesion (HSIL were included in our study. Results and Conclusions: ProEx C was positive in 14 of HSILs (100%, 3 of 19 LSILs (16%, 2 of 4 ASC-Hs, and none of ASC-USs (0%. The ProEx C test showed very intense nuclear staining in all cytologically abnormal cells. Further studies are indicated to evaluate the diagnostic role of ProEx C.

  3. BATING A REFERENCE INSTALLATION BASED ON CONTROLLED-POTENTIAL COULOMETRY METOD IN THE FRAME OF IMPROVING THE STATE PRIMARY STANDARD GET 176 AND ITS MEASUREMENT CAPABILITIES

    Directory of Open Access Journals (Sweden)

    V. M. Zyskin

    2016-01-01

    Full Text Available The results of developing of reference installation, based on a controlled-potential coulometry, in the frame of improving the State primary standard of the units of mass (molar fraction and mass (molar concentration of a component in the liquid and solid substances and materials GET 176 are presented. The physical principles of controlled-potential coulometry, content and metrological characteristics of the developed installation are considered. Measurement results of copper, iron and lead contents in the certified reference materials of metals' solutions and CRM of brass produced by BAM, Germany, obtained using reference installation are given.

  4. Measurement of the fluorine content of three NBS standard reference materials by use of the /sup 19/F(p, p'. gamma. )/sup 19/F reaction

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, A L; Kraner, H W; Shroy, R E; Jones, K W [Brookhaven National Lab., Upton, NY (USA)

    1984-08-01

    The fluorine contents of National Bureau of Standards (NBS) Standard Reference Materials (SRM) 91, opal glass; 120b, phosphate rock; and 2671a, freeze-dried urine; have been measured using the /sup 19/F(p,p'..gamma..)/sup 19/F reaction at a proton energy of 3.1 MeV. The results are in good agreement with the values certified by the NBS.

  5. Acute stress among adolescents and female rape victims measured by ASC-Kids: a pilot study.

    Science.gov (United States)

    Nilsson, Doris; Nordenstam, Carin; Green, Sara; Wetterhall, Annika; Lundin, Tom; Svedin, Carl Göran

    2015-01-01

    Rape is considered a stressful trauma and often with durable consequences. How the aftermath of rape is for young adolescents' girls considering acute stress is an overlooked field and remains to be studied. In this study, we wanted to investigate acute stress among adolescent victims of rape and the psychometric properties of the Acute Stress Checklist for Children (ASC-Kids). A clinical sample (n = 79) of raped girls, 13-17 years old who had turned to a special rape victim unit for treatment, answered the ASC-Kids. ASC-Kids was also given to a group of minor stressed, non-raped adolescents in the same age range (n = 154) together with the University of California at Los Angeles Post-traumatic Stress Disorder Reaction Index (UCLA PTSD RI), and the Sense of Coherence Scale 13 (SOC-13). The scores from the groups were compared and showed significant differences in mean values on all the diagnostic criteria of acute stress disorder. In the clinical group, 36.7% obtained full ASD criteria. ASC-Kids could discriminate well between groups. Cronbach's alpha was found to be excellent, and the correlation between the UCLA PTSD RI and ASC-Kids found to be good; both ASC-Kids and UCLA PTSD RI had a good and moderate negative correlation with SOC-13. Adolescent female rape victims were shown to have a very high level of acute stress, and the ASC-Kids was found to have sound psychometrics and can be a valuable screening instrument to support clinicians in their assessments of an indication of adolescents after potentially stressful events such as rape.

  6. 38 CFR 0.735-10 - Cross-reference to employee ethical and other conduct standards and financial disclosure...

    Science.gov (United States)

    2010-07-01

    ... employee ethical and other conduct standards and financial disclosure regulations. 0.735-10 Section 0.735-10 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS STANDARDS OF ETHICAL CONDUCT AND RELATED RESPONSIBILITIES Standards of Ethical Conduct and Related Responsibilities of...

  7. Official ERS technical standards: Global Lung Function Initiative reference values for the carbon monoxide transfer factor for Caucasians.

    Science.gov (United States)

    Stanojevic, Sanja; Graham, Brian L; Cooper, Brendan G; Thompson, Bruce R; Carter, Kim W; Francis, Richard W; Hall, Graham L

    2017-09-01

    There are numerous reference equations available for the single-breath transfer factor of the lung for carbon monoxide ( T  LCO ); however, it is not always clear which reference set should be used in clinical practice. The aim of the study was to develop the Global Lung Function Initiative (GLI) all-age reference values for T  LCO Data from 19 centres in 14 countries were collected to define T  LCO reference values. Similar to the GLI spirometry project, reference values were derived using the LMS (lambda, mu, sigma) method and the GAMLSS (generalised additive models for location, scale and shape) programme in R.12 660 T  LCO measurements from asymptomatic, lifetime nonsmokers were submitted; 85% of the submitted data were from Caucasians. All data were uncorrected for haemoglobin concentration. Following adjustments for elevation above sea level, gas concentration and assumptions used for calculating the anatomic dead space volume, there was a high degree of overlap between the datasets. Reference values for Caucasians aged 5-85 years were derived for T  LCO , transfer coefficient of the lung for carbon monoxide and alveolar volume.This is the largest collection of normative T  LCO data, and the first global reference values available for T  LCO . Copyright ©ERS 2017.

  8. The determination, by instrumental neutron-activation analysis, of some elements in the NIMROC standard reference materials

    International Nuclear Information System (INIS)

    Eddy, B.T.; Pearton, D.C.G.; Bibby, D.M.

    1975-01-01

    Instrumental neutron-activation analysis was used for the determination of sixteen trace and minor elements in the six NIMROC reference materials. Six reference rock materials prepared by the U.S. Geological Survey were also analysed, and the results were compared with the recommended, average, or magnitude values given for these rocks by Flanagan. The agreement between the two sets of results was found to be generally good, indicating that INAA is an acceptable technique for the determination of most of these elements. The values found for the NIMROC samples represent a significant contribution to the evaluation of the trace elements in these reference materials [af

  9. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    Science.gov (United States)

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  10. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the VSL and the BIPM

    DEFF Research Database (Denmark)

    Alvarez, J.T.; De Pooter, J.A.; Andersen, Claus E.

    2014-01-01

    An indirect comparison of the standards for reference air kerma rate for 192Ir high dose rate brachytherapy sources of the Dutch Metrology Institute (VSL), The Netherlands, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the VSL in November 2009. The comparison resu...

  11. [Studies on the identification of psychotropic substances. VIII. Preparation and various analytical data of reference standard of some stimulants, amfepramone, cathinone, N-ethylamphetamine, fenethylline, fenproporex and mefenorex].

    Science.gov (United States)

    Shimamine, M; Takahashi, K; Nakahara, Y

    1992-01-01

    The Reference Standards for amfepramone, cathinone, N-ethylamphetamine, fenethylline, fenproporex and mefenorex were prepared. Their purities determined by HPLC were more than 99.5%. For the identification and determination of these six drugs, their analytical data were measured and discussed by TLC, UV, IR, HPLC, GC/MS and NMR.

  12. Single-Molecule Fluorescence Reveals the Oligomerization and Folding Steps Driving the Prion-like Behavior of ASC.

    Science.gov (United States)

    Gambin, Yann; Giles, Nichole; O'Carroll, Ailís; Polinkovsky, Mark; Hunter, Dominic; Sierecki, Emma

    2018-02-16

    Single-molecule fluorescence has the unique ability to quantify small oligomers and track conformational changes at a single-protein level. Here we tackled one of the most extreme protein behaviors, found recently in an inflammation pathway. Upon danger recognition in the cytosol, NLRP3 recruits its signaling adaptor, ASC. ASC start polymerizing in a prion-like manner and the system goes in "overdrive" by producing a single micron-sized "speck." By precisely controlling protein expression levels in an in vitro translation system, we could trigger the polymerization of ASC and mimic formation of specks in the absence of inflammasome nucleators. We utilized single-molecule spectroscopy to fully characterize prion-like behaviors and self-propagation of ASC fibrils. We next used our controlled system to monitor the conformational changes of ASC upon fibrillation. Indeed, ASC consists of a PYD and CARD domains, separated by a flexible linker. Individually, both domains have been found to form fibrils, but the structure of the polymers formed by the full-length ASC proteins remains elusive. For the first time, using single-molecule Förster resonance energy transfer, we studied the relative positions of the CARD and PYD domains of full-length ASC. An unexpectedly large conformational change occurred upon ASC fibrillation, suggesting that the CARD domain folds back onto the PYD domain. However, contradicting current models, the "prion-like" conformer was not initiated by binding of ASC to the NLRP3 platform. Rather, using a new method, hybrid between Photon Counting Histogram and Number and Brightness analysis, we showed that NLRP3 forms hexamers with self-binding affinities around 300nM. Overall our data suggest a new mechanism, where NLRP3 can initiate ASC polymerization simply by increasing the local concentration of ASC above a supercritical level. Copyright © 2017. Published by Elsevier Ltd.

  13. Comparison of Simulated Microgravity and Hydrostatic Pressure for Chondrogenesis of hASC.

    Science.gov (United States)

    Mellor, Liliana F; Steward, Andrew J; Nordberg, Rachel C; Taylor, Michael A; Loboa, Elizabeth G

    2017-04-01

    Cartilage tissue engineering is a growing field due to the lack of regenerative capacity of native tissue. The use of bioreactors for cartilage tissue engineering is common, but the results are controversial. Some studies suggest that microgravity bioreactors are ideal for chondrogenesis, while others show that mimicking hydrostatic pressure is crucial for cartilage formation. A parallel study comparing the effects of loading and unloading on chondrogenesis has not been performed. The goal of this study was to evaluate chondrogenesis of human adipose-derived stem cells (hASC) under two different mechanical stimuli relative to static culture: microgravity and cyclic hydrostatic pressure (CHP). Pellets of hASC were cultured for 14 d under simulated microgravity using a rotating wall vessel bioreactor or under CHP (7.5 MPa, 1 Hz, 4 h · d-1) using a hydrostatic pressure vessel. We found that CHP increased mRNA expression of Aggrecan, Sox9, and Collagen II, caused a threefold increase in sulfated glycosaminoglycan production, and resulted in stronger vimentin staining intensity and organization relative to microgravity. In addition, Wnt-signaling patterns were altered in a manner that suggests that simulated microgravity decreases chondrogenic differentiation when compared to CHP. Our goal was to compare chondrogenic differentiation of hASC using a microgravity bioreactor and a hydrostatic pressure vessel, two commonly used bioreactors in cartilage tissue engineering. Our results indicate that CHP promotes hASC chondrogenesis and that microgravity may inhibit hASC chondrogenesis. Our findings further suggest that cartilage formation and regeneration might be compromised in space due to the lack of mechanical loading.Mellor LF, Steward AJ, Nordberg RC, Taylor MA, Loboa EG. Comparison of simulated microgravity and hydrostatic pressure for chondrogenesis of hASC. Aerosp Med Hum Perform. 2017; 88(4):377-384.

  14. Prediction of cervical intraepithelial neoplasia grade 2+ (CIN2+ using HPV DNA testing after a diagnosis of atypical squamous cell of undetermined significance (ASC-US in Catalonia, Spain

    Directory of Open Access Journals (Sweden)

    Ibáñez Raquel

    2012-01-01

    Full Text Available Abstract Background A protocol for cervical cancer screening among sexually active women 25 to 65 years of age was introduced in 2006 in Catalonia, Spain to increase coverage and to recommend a 3-year-interval between screening cytology. In addition, Human Papillomavirus (HPV was offered as a triage test for women with a diagnosis of atypical squamous cells of undetermined significance (ASC-US. HPV testing was recommended within 3 months of ASC-US diagnosis. According to protocol, HPV negative women were referred to regular screening including a cytological exam every 3 years while HPV positive women were referred to colposcopy and closer follow-up. We evaluated the implementation of the protocol and the prediction of HPV testing as a triage tool for cervical intraepithelial lesions grade two or worse (CIN2+ in women with a cytological diagnosis of ASC-US. Methods During 2007-08 a total of 611 women from five reference laboratories in Catalonia with a novel diagnosis of ASC-US were referred for high risk HPV (hrHPV triage using high risk Hybrid Capture version 2. Using routine record linkage data, women were followed for 3 years to evaluate hrHPV testing efficacy for predicting CIN2+ cases. Logistic regression analysis was used to estimate the odds ratio for CIN2 +. Results Among the 611 women diagnosed with ASC-US, 493 (80.7% had at least one follow-up visit during the study period. hrHPV was detected in 48.3% of the women at study entry (mean age 35.2 years. hrHPV positivity decreased with increasing age from 72.6% among women younger than 25 years to 31.6% in women older than 54 years (p At the end of the 3 years follow-up period, 37 women with a diagnosis of CIN2+ (18 CIN2, 16 CIN3, 2 cancers, and 1 with high squamous intraepithelial lesions -HSIL were identified and all but one had a hrHPV positive test at study entry. Sensitivity to detect CIN2+ of hrHPV was 97.2% (95%confidence interval (CI = 85.5-99.9 and specificity was 68.3% (95%CI

  15. Prediction of cervical intraepithelial neoplasia grade 2+ (CIN2+) using HPV DNA testing after a diagnosis of atypical squamous cell of undetermined significance (ASC-US) in Catalonia, Spain.

    Science.gov (United States)

    Ibáñez, Raquel; Moreno-Crespi, Judit; Sardà, Montserrat; Autonell, Josefina; Fibla, Montserrat; Gutiérrez, Cristina; Lloveras, Belen; Alejo, María; Català, Isabel; Alameda, Francesc; Casas, Miquel; Bosch, F Xavier; de Sanjosé, Silvia

    2012-01-26

    A protocol for cervical cancer screening among sexually active women 25 to 65 years of age was introduced in 2006 in Catalonia, Spain to increase coverage and to recommend a 3-year-interval between screening cytology. In addition, Human Papillomavirus (HPV) was offered as a triage test for women with a diagnosis of atypical squamous cells of undetermined significance (ASC-US). HPV testing was recommended within 3 months of ASC-US diagnosis. According to protocol, HPV negative women were referred to regular screening including a cytological exam every 3 years while HPV positive women were referred to colposcopy and closer follow-up. We evaluated the implementation of the protocol and the prediction of HPV testing as a triage tool for cervical intraepithelial lesions grade two or worse (CIN2+) in women with a cytological diagnosis of ASC-US. During 2007-08 a total of 611 women from five reference laboratories in Catalonia with a novel diagnosis of ASC-US were referred for high risk HPV (hrHPV) triage using high risk Hybrid Capture version 2. Using routine record linkage data, women were followed for 3 years to evaluate hrHPV testing efficacy for predicting CIN2+ cases. Logistic regression analysis was used to estimate the odds ratio for CIN2 +. Among the 611 women diagnosed with ASC-US, 493 (80.7%) had at least one follow-up visit during the study period. hrHPV was detected in 48.3% of the women at study entry (mean age 35.2 years). hrHPV positivity decreased with increasing age from 72.6% among women younger than 25 years to 31.6% in women older than 54 years (p < 0.01). At the end of the 3 years follow-up period, 37 women with a diagnosis of CIN2+ (18 CIN2, 16 CIN3, 2 cancers, and 1 with high squamous intraepithelial lesions--HSIL) were identified and all but one had a hrHPV positive test at study entry. Sensitivity to detect CIN2+ of hrHPV was 97.2% (95%confidence interval (CI) = 85.5-99.9) and specificity was 68.3% (95%CI = 63.1-73.2). The odds ratio for CIN2

  16. MicroASC instrument onboard Juno spacecraft utilizing inertially controlled imaging

    DEFF Research Database (Denmark)

    Pedersen, David Arge Klevang; Jørgensen, Andreas Härstedt; Benn, Mathias

    2016-01-01

    This contribution describes the post-processing of the raw image data acquired by the microASC instrument during the Earth-fly-by of the Juno spacecraft. The images show a unique view of the Earth and Moon system as seen from afar. The procedure utilizes attitude measurements and inter......-calibration of the Camera Head Units of the microASC system to trigger the image capturing. The triggering is synchronized with the inertial attitude and rotational phase of the sensor acquiring the images. This is essentially works as inertially controlled imaging facilitating image acquisition from unexplored...

  17. Fundamentals of civil engineering an introduction to the ASCE body of knowledge

    CERN Document Server

    McCuen, Richard H; Wong, Melanie K

    2011-01-01

    While the ASCE Body of Knowledge (BOK2) is the codified source for all technical and non-technical information necessary for those seeking to attain licensure in civil engineering, recent graduates have notoriously been lacking in the non-technical aspects even as they excel in the technical. Fundamentals of Civil Engineering: An Introduction to the ASCE Body of Knowledge addresses this shortfall and helps budding engineers develop the knowledge, skills, and attitudes suggested and implied by the BOK2. Written as a resource for all of the non-technical outcomes not specifically covered in the

  18. Required number of records for ASCE/SEI 7 ground-motion scaling procedure

    Science.gov (United States)

    Reyes, Juan C.; Kalkan, Erol

    2011-01-01

    The procedures and criteria in 2006 IBC (International Council of Building Officials, 2006) and 2007 CBC (International Council of Building Officials, 2007) for the selection and scaling ground-motions for use in nonlinear response history analysis (RHA) of structures are based on ASCE/SEI 7 provisions (ASCE, 2005, 2010). According to ASCE/SEI 7, earthquake records should be selected from events of magnitudes, fault distance, and source mechanisms that comply with the maximum considered earthquake, and then scaled so that the average value of the 5-percent-damped response spectra for the set of scaled records is not less than the design response spectrum over the period range from 0.2Tn to 1.5Tn sec (where Tn is the fundamental vibration period of the structure). If at least seven ground-motions are analyzed, the design values of engineering demand parameters (EDPs) are taken as the average of the EDPs determined from the analyses. If fewer than seven ground-motions are analyzed, the design values of EDPs are taken as the maximum values of the EDPs. ASCE/SEI 7 requires a minimum of three ground-motions. These limits on the number of records in the ASCE/SEI 7 procedure are based on engineering experience, rather than on a comprehensive evaluation. This study statistically examines the required number of records for the ASCE/SEI 7 procedure, such that the scaled records provide accurate, efficient, and consistent estimates of" true" structural responses. Based on elastic-perfectly-plastic and bilinear single-degree-of-freedom systems, the ASCE/SEI 7 scaling procedure is applied to 480 sets of ground-motions. The number of records in these sets varies from three to ten. The records in each set were selected either (i) randomly, (ii) considering their spectral shapes, or (iii) considering their spectral shapes and design spectral-acceleration value, A(Tn). As compared to benchmark (that is, "true") responses from unscaled records using a larger catalog of ground

  19. [Reference values of apolipoproteins A1 and B. Contribution of international standardization. Travail collaboratif entre la SFBC, l'Arcol et le SFRL].

    Science.gov (United States)

    Steinmetz, J; Caces, E; Couderc, R; Beucler, I; Legrand, A; Henny, J

    1997-01-01

    The utilization of two WHO reference materials, liquid and lyophilized, permitted international standardization of apolipoprotein measurements. We report here the results of a collaborative study between Arcol, SFBC and SFRL in order to establish reference ranges for apo A1 and B on nine standardized systems. A population of 1027 men and women supposed healthy, 4 to 60 year old, have been selected in two Centers for Preventive Medicine. The serum samples were aliquoted frozen at -20 degrees C the day of sampling and analysed by the manufacturers with IFCC standardized calibrants. A specific quality control was performed using a frozen pool of sera. For apo A1, the centile 2.5 of the reference population varies from 1.04 to 1.16 g/l. The range values for the centile 97.5 varies from 1.87 to 2.24 g/l. For apoB, the centile 2.5 varies from 0.43 to 0.57 g/l, and the centile 97.5 from 1.30 to 1.39 g/l. Only one system has a problem of dispersion with an upper limit equal to 1.20 g/l. These results improve that international standardization allowed actually a good comparability of the results, especially for apoB.

  20. Absolute Salinity, ''Density Salinity'' and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    Science.gov (United States)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2011-01-01

    Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models. First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. However, the Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies. Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol SAdens; it stands out as the most appropriate representation of salinity for use in dynamical physical

  1. Absolute Salinity, "Density Salinity" and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    Science.gov (United States)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2010-08-01

    Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models. First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. The Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies. Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol SAdens; it stands out as the most appropriate representation of salinity for use in dynamical physical

  2. Absolute Salinity, ''Density Salinity'' and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    Directory of Open Access Journals (Sweden)

    D. G. Wright

    2011-01-01

    Full Text Available Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models.

    First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. However, the Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies.

    Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol

  3. Non-destructive alpha-particle activation analysis of P, Cl, K and Ca in marine macro-alga samples using synthetic multielement reference material as comparative standard

    International Nuclear Information System (INIS)

    Iwata, Y.; Naitoh, H.; Suzuki, N.

    1992-01-01

    A Synthetic Reference Material (SyRM) composed with accurately known amounts of 12 elements has been prepared. The elemental composition of the SyRM is closely similar to that of marine macro-algae sample. The elemental composition of the SyRM was regulated by the starting materials used for the synthesis. The SyRM was used as a comparative standard for non-destructive alpha-particle activation analysis of marine macro-alga samples. P, Cl, K and Ca were determined simultaneously without correction for alpha range due to difference in the elemental composition between the analytical samples and the comparative standard. (author) 19 refs.; 4 tabs

  4. An administrative data validation study of the accuracy of algorithms for identifying rheumatoid arthritis: the influence of the reference standard on algorithm performance.

    Science.gov (United States)

    Widdifield, Jessica; Bombardier, Claire; Bernatsky, Sasha; Paterson, J Michael; Green, Diane; Young, Jacqueline; Ivers, Noah; Butt, Debra A; Jaakkimainen, R Liisa; Thorne, J Carter; Tu, Karen

    2014-06-23

    We have previously validated administrative data algorithms to identify patients with rheumatoid arthritis (RA) using rheumatology clinic records as the reference standard. Here we reassessed the accuracy of the algorithms using primary care records as the reference standard. We performed a retrospective chart abstraction study using a random sample of 7500 adult patients under the care of 83 family physicians contributing to the Electronic Medical Record Administrative data Linked Database (EMRALD) in Ontario, Canada. Using physician-reported diagnoses as the reference standard, we computed and compared the sensitivity, specificity, and predictive values for over 100 administrative data algorithms for RA case ascertainment. We identified 69 patients with RA for a lifetime RA prevalence of 0.9%. All algorithms had excellent specificity (>97%). However, sensitivity varied (75-90%) among physician billing algorithms. Despite the low prevalence of RA, most algorithms had adequate positive predictive value (PPV; 51-83%). The algorithm of "[1 hospitalization RA diagnosis code] or [3 physician RA diagnosis codes with ≥1 by a specialist over 2 years]" had a sensitivity of 78% (95% CI 69-88), specificity of 100% (95% CI 100-100), PPV of 78% (95% CI 69-88) and NPV of 100% (95% CI 100-100). Administrative data algorithms for detecting RA patients achieved a high degree of accuracy amongst the general population. However, results varied slightly from our previous report, which can be attributed to differences in the reference standards with respect to disease prevalence, spectrum of disease, and type of comparator group.

  5. Standard reference and other important nuclear data. Supplement 1 to the report BNL-NCS-51123 (Dec. 1979) = ENDF-300 = IAEA-NDS-15/300 (microfiche)

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, M R [ed.

    1981-03-01

    The document contains inserts to be added to the report `Standard Reference and Other Important Nuclear Data` (BNL-NCS-51123, ENDF-300), including the following two articles: Fast Neutron Capture in {sup 238}U and {sup 232}Th by W.P. Poentiz (ANL), and {sup 239}Pu Decay Power Discrepancy by T.R. England and P.G. Young (LANL) Refs, figs

  6. A medical-legal review regarding the standard of care for epidural injections, with particular reference to a closed case.

    Science.gov (United States)

    Helm, Standiford; Glaser, Scott; Falco, Frank; Henry, Brian

    2010-01-01

    Interventional pain management is an evolving field, with a primary focus on the safety of the patient. One major source of risk to patients is intraarterial or intraneural injections. Interventional pain physicians have considerable interest in identifying techniques which avoid these complications. A recent article has reviewed complications associated with interventional procedures and concluded that the complications were due to deviation from a specific prescribed protocol. One of the cases reviewed went to jury trial and the record of that case is in the public domain. Two of the authors of the recent review were expert witnesses in the trial. They provided conflicting testimony as to alleged violations of the standard of care. Their criticisms also differed from a third criticism contained in the article as well as the protocol being advocated in the article, thus contravening the claim that there is one prescribed protocol which must be followed. The definition of standard of care varies amongst jurisdictions, but is generally defined as either that care which a reasonably well-trained physician in that specialty would provide under similar circumstances or as what would constitute reasonable medical care under the circumstances presented. Analysis of the case which went to trial indicates that there is not one prescribed protocol which must be followed; the definition of standard of care is broader than that. Interventional pain management is an evolving field and the standard of care is broadly defined.

  7. Profiling Autism Symptomatology: An Exploration of the Q-ASC Parental Report Scale in Capturing Sex Differences in Autism

    Science.gov (United States)

    Ormond, Sarah; Brownlow, Charlotte; Garnett, Michelle Sarah; Rynkiewicz, Agnieszka; Attwood, Tony

    2018-01-01

    The Questionnaire for Autism Spectrum Conditions (Q-ASC) was developed by Attwood et al. (2011) to identify gender-sensitive profiles of autism symptomatology; prioritise and adjust the direction of clinical interventions; and support positive psychosocial outcomes and prognosis into adulthood. The current research piloted the Q-ASC with parents…

  8. Structure and assembly of the mouse ASC inflammasome by combined NMR spectroscopy and cryo-electron microscopy

    Science.gov (United States)

    Sborgi, Lorenzo; Ravotti, Francesco; Dandey, Venkata P.; Dick, Mathias S.; Mazur, Adam; Reckel, Sina; Chami, Mohamed; Scherer, Sebastian; Huber, Matthias; Böckmann, Anja; Egelman, Edward H.; Stahlberg, Henning; Broz, Petr; Meier, Beat H.; Hiller, Sebastian

    2015-01-01

    Inflammasomes are multiprotein complexes that control the innate immune response by activating caspase-1, thus promoting the secretion of cytokines in response to invading pathogens and endogenous triggers. Assembly of inflammasomes is induced by activation of a receptor protein. Many inflammasome receptors require the adapter protein ASC [apoptosis-associated speck-like protein containing a caspase-recruitment domain (CARD)], which consists of two domains, the N-terminal pyrin domain (PYD) and the C-terminal CARD. Upon activation, ASC forms large oligomeric filaments, which facilitate procaspase-1 recruitment. Here, we characterize the structure and filament formation of mouse ASC in vitro at atomic resolution. Information from cryo-electron microscopy and solid-state NMR spectroscopy is combined in a single structure calculation to obtain the atomic-resolution structure of the ASC filament. Perturbations of NMR resonances upon filament formation monitor the specific binding interfaces of ASC-PYD association. Importantly, NMR experiments show the rigidity of the PYD forming the core of the filament as well as the high mobility of the CARD relative to this core. The findings are validated by structure-based mutagenesis experiments in cultured macrophages. The 3D structure of the mouse ASC-PYD filament is highly similar to the recently determined human ASC-PYD filament, suggesting evolutionary conservation of ASC-dependent inflammasome mechanisms. PMID:26464513

  9. Simultaneous determination of theobromine, (+)-catechin, caffeine, and (-)-epicatechin in standard reference material baking chocolate 2384, cocoa, cocoa beans, and cocoa butter.

    Science.gov (United States)

    Risner, Charles H

    2008-01-01

    A reverse-phase liquid chromatography analysis is used to access the quantity of theobromine, (+)-catechin, caffeine, and (-)-epicatechin in Standard Reference Material 2384 Baking Chocolate, cocoa, cocoa beans, and cocoa butter using water or a portion of the mobile phase as the extract. The procedure requires minimal sample preparation. Theobromine, (+)-catechin, caffeine, and (-)-epicatechin are detected by UV absorption at 273 nm after separation using a 0.3% acetic acid-methanol gradient (volume fractions) and quantified using external standards. The limit of detection for theobromine, (+)-catechin, caffeine, and (-)-epicatechin averages 0.08, 0.06, 0.06, and 0.06 microg/mL, respectively. The method when applied to Standard Reference Material 2384 Baking Chocolate; baking chocolate reference material yields results that compare to two different, separate procedures. Theobromine ranges from 26000 mg/kg in cocoa to 140 mg/kg in cocoa butter; (+)-catechin from 1800 mg/kg in cocoa to below detection limits of theobromine, 100.0 +/- 0.6 for (+)-catechin, 96.2 +/- 2.1 for caffeine, and 106.2 +/- 1.7 for (-)-epicatechin.

  10. 18 CFR Appendix 1 to Part 301 - ASC Utility Filing Template

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false ASC Utility Filing Template 1 Appendix 1 to Part 301 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS FOR FEDERAL POWER MARKETING ADMINISTRATIONS AVERAGE SYSTEM COST...

  11. Aeroacoustics research in Europe : the CEAS-ASC report on 1997 highlights

    NARCIS (Netherlands)

    Rienstra, S.W.

    1998-01-01

    This paper is a report on the highlights of aeroacoustics research and development in Europe in 1997, compiled from information provided in the CEAS Aeroacoustics Specialists Committee (ASC). The Confederation of European Aerospace Societies (CEAS) comprises the national Aerospace Societies of

  12. Accelerating the deployment of supply chain strategies through the adoption of standard operations reference model for supply chains producing capacity

    Energy Technology Data Exchange (ETDEWEB)

    Toews, A. [Project Plato Inc., Calgary, AB (Canada)

    2004-07-01

    This PowerPoint presentation provided information on how to build a procurement organization in the energy sector with reference to aligning supply chain management with corporate objectives to enhance response time in transactions with suppliers and customers. The paper examined the degree to which procurement functions are centralized versus decentralized and which combinations work best. It also examined how e-commerce can improve the efficiency and effectiveness of the procurement function and add value to an organization. The author emphasized the importance of a multi-functional team to create a successful sourcing strategy and develop strong purchasing capabilities within the organization. tabs., figs.

  13. Improving rehabilitation standards to meet changing community concerns: A history of uranium mine rehabilitation with particular reference to Northern Australia

    International Nuclear Information System (INIS)

    Waggitt, P.W.; Zapantis, A.

    2002-01-01

    Rehabilitation of land after mining is an issue that society has been wrestling with for at least 400 years. The issue is made even more emotive when the mineral extracted has been uranium. Over the past 50 years or so society has become ever more aware of the environment and the level of concern for proper environmental management has also increased. Today the community expects that mining in general, and uranium mining in particular, will be undertaken in an environmentally sensitive manner. As a consequence the expectations and standards for rehabilitation demanded by the community and regulators have been increasing and improving over time. Today the rehabilitation process is driven by issues of sustainable development, stakeholder involvement and consultation, inter-and intragenerational equity and a strong desire for environmental protection to be of the highest order. The paper describes this progressive improvement in rehabilitation standards using the uranium mines of northern Australia as case histories. (author)

  14. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    Science.gov (United States)

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  15. Quality assessment of Chrysanthemum indicum Flower by simultaneous quantification of six major ingredients using a single reference standard combined with HPLC fingerprint analysis

    Directory of Open Access Journals (Sweden)

    Jiao He

    2016-04-01

    Full Text Available Chrysanthemum indicum Flower is usually consumed as functional food. This paper described an improved total quality assessment method for Chrysanthemum indicum Flower by simultaneous quantitation using a single standard to determine multi-components method combined with high performance liquid chromatography fingerprint analysis. Six main components of Chrysanthemum indicum Flower including two flavonoids and four phenolic acids were simultaneously quantified using linarin as the internal reference standard. The method was fully validated with respect to linearity, precision, accuracy, robustness and stability. The validated method was successfully applied to the analysis of thirty three batches of Chrysanthemum indicum Flower samples. Under the same chromatographic conditions, fingerprint analysis in combination with Similarity analysis and principal component analysis was performed to identify the samples from different regions. In general, an effective assessment using a single standard to determinate multi-components method combined with fingerprint analysis make the reliable qualitation and quantitation analysis of Chrysanthemum indicum Flower available.

  16. PRELIMINARY RESULTS OF THE COMPARISON OF SATELLITE IMAGERS USING TUZ GÖLÜ AS A REFERENCE STANDARD

    Directory of Open Access Journals (Sweden)

    H. Özen

    2012-07-01

    Full Text Available Earth surfaces, such as deserts, salt lakes, and playas, have been widely used in the vicarious radiometric calibration of optical earth observation satellites. In 2009, the Infrared and Visible Optical Sensors (IVOS sub-group of the Committee of Earth Observation Satellites (CEOS Working Group on Calibration and Validation (WGCV designated eight LANDNET reference sites to focus international efforts, facilitate traceability and enable the establishment of measurement "best practices." With support from the European Space Agency (ESA, one of the LANDNET sites, the Tuz Gölü salt lake located in central Turkey, was selected to host a cross-comparison of measurement instrumentation and methodologies conducted by 11 different ground teams across the globe. This paper provides an overview of the preliminary results of the cross-comparison of the ground-based spectral measurements made during the CEOS Land Comparison 13-27 August, 2010 with the simultaneous satellite image data acquisitions of the same site.

  17. Test imf kursus - Referred Pain and Sensations Evoked by Standardized Palpation of the Masseter Muscle in Healthy Participants

    DEFF Research Database (Denmark)

    Masuda, Manabu; Iida, Takashi; Exposto, Fernando G

    2018-01-01

    , Tukey post hoc, and McNemar's tests with a 5% level of significance. RESULTS: Referred pain/sensations were most commonly evoked with the 2.0-kg stimulus (34.4% of participants; P significant effects of stimulus intensity on NRS...... scores for pain and unpleasantness, as well as for aftersensation (P significant effects on NRS scores for pain and unpleasantness for the 1.0- and 2.0-kg stimuli (P 2.0-kg stimulus (P .... The right masseter muscle was divided into 15 test sites. Mechanical sensitivity of the masseter was assessed with three mechanical stimuli (0.5 kg, 1.0 kg, or 2.0 kg) applied by palpometers to the 15 test sites for 5 seconds each site. Participants scored the perceived intensity of pain and unpleasantness...

  18. Technical Note: Modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies

    International Nuclear Information System (INIS)

    Konstantinidis, Anastasios C.; Olivo, Alessandro; Speller, Robert D.

    2011-01-01

    Purpose: The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (FPN) to avoid contamination from nonstochastic processes. The ''gold standard'' method used for the reduction of the FPN (i.e., the different gain between pixels) in linear x-ray detectors is based on normalization with an average reference flat-field. However, the noise in the corrected image depends on the number of flat frames used for the average flat image. The aim of this study is to modify the standard gain correction algorithm to make it independent on the used reference flat frames. Methods: Many publications suggest the use of 10-16 reference flat frames, while other studies use higher numbers (e.g., 48 frames) to reduce the propagated noise from the average flat image. This study quantifies experimentally the effect of the number of used reference flat frames on the NPS and DQE values and appropriately modifies the gain correction algorithm to compensate for this effect. Results: It is shown that using the suggested gain correction algorithm a minimum number of reference flat frames (i.e., down to one frame) can be used to eliminate the FPN from the raw flat image. This saves computer memory and time during the x-ray performance evaluation. Conclusions: The authors show that the method presented in the study (a) leads to the maximum DQE value that one would have by using the conventional method and very large number of frames and (b) has been compared to an independent gain correction method based on the subtraction of flat-field images, leading to identical DQE values. They believe this provides robust validation of the proposed method.

  19. Certification of a reference material for determination of total cyanide in soil to support implementation of the International Standard ISO 11262:2011.

    Science.gov (United States)

    Scharf, Holger; Bremser, Wolfram

    2015-04-01

    Cyanides are among the most important inorganic pollutants to be tested and monitored in environmental compartments. They can be distinguished and determined as free cyanide, weak acid dissociable cyanide or as total cyanide. However, in any case obtained, measurement results are operationally defined referring to the applied analytical method. In 2011, the International Standard ISO 11262 has been published which specifies a normative analytical method for the determination of total cyanide in soil. The objective of the project described in this paper was to provide the first soil reference material (CRM) certified for its mass fraction of total cyanide on the basis of this standard. A total of 12 German laboratories with proven experience in the determination of cyanides in environmental samples participated in the certification study. Measurement results were evaluated in full compliance with the requirements of ISO Guide 35. Taking into account the results of the inter-laboratory comparison as well as the outcome of the homogeneity and stability studies, a certified mass fraction of total cyanide of 21.1 mg/kg and an expanded uncertainty (k = 2) of 1.3 mg/kg were assigned to the material. The reference material has been issued as CRM BAM-U114.

  20. Reference Data for Standardized Quality of Life Questionnaires in Indian Patients with Brain Metastases from Non-small Cell Lung Cancer: Results from a Prospective Study.

    Science.gov (United States)

    Aggarwal, Jaiprakash; Chakraborty, Santam; Ghosh Laskar, Sarbani; Patil, Vijay M; Prabhash, Kumar; Bhattacharya, Atanu; Noronha, Vanita; Purandare, Nilendu C; Joshi, Amit; Mummudi, Naveen; Arora, Jitendra; Badhe, Rupali

    2017-04-10

    Reference data for European Organization for Research and Treatment of Cancer (EORTC) quality of life questionnaires do not include studies from the Indian subcontinent. The objective of the current study was to establish a reference dataset for Indian patients of non-small cell lung cancer (NSCLC) presenting with brain metastases (BM). One hundred forty patients with NSCLC with BM treated between 2012-2015 were registered in a prospective cohort study (CTRI/2013/01/003299). The baseline quality of life was evaluated using the EORTC general quality of life questionnaire QLQ-C30 and lung cancer specific module LC13. Minimum important difference (MID) scores for individual domains of the EORTC QLQ-C30 and LC13 questionnaires were derived (MID = 0.2 x standard deviation) from the reference data for patients with recurrent/metastatic lung cancers. In addition, a systematic review was conducted to identify studies reporting baseline quality of life scores for recurrent/metastatic NSCLC. Scores of several functional as well as symptom scales in the current NSCLC population differed by more than the MID from the baseline mean scores in the reference EORTC population as well as that reported from other studies. Differences in mean score from the EORTC reference data ranged from 6.2 and 9.4 points for the role functioning and cognitive functioning domains. In the symptom scales, the largest differences were observed for the financial difficulties (23.9) scores for the QLQ-C30 and peripheral neuropathy (21.7) for LC13 questionnaires. The current study demonstrates that baseline reference scores need to be established for patients from the Indian subcontinent. The findings from the current study have important implications for studies employing quality of life (QOL) assessment in the Indian NSCLC patient population.

  1. Using Florida Keys Reference Sites As a Standard for Restoration of Forest Structure in Everglades Tree Islands

    International Nuclear Information System (INIS)

    Ross, M.S.; Sah, J.P.; Ruiz, P.L.; Ross, M.S.; Ogurcak, D.E.

    2010-01-01

    In south Florida, tropical hardwood forests (hammocks) occur in Everglades tree islands and as more extensive forests in coastal settings in the nearby Florida Keys. Keys hammocks have been less disturbed by humans, and many qualify as old-growth, while Everglades hammocks have received much heavier use. With improvement of tree island condition an important element in Everglades restoration efforts, we examined stand structure in 23 Keys hammocks and 69 Everglades tree islands. Based on Stand Density Index and tree diameter distributions, many Everglades hammocks were characterized by low stocking and under-representation in the smaller size classes. In contrast, most Keys forests had the dense canopies and open under stories usually associated with old-growth hardwood hammocks. Subject to the same caveats that apply to off-site references elsewhere, structural information from mature Keys hammocks can be helpful in planning and implementing forest restoration in Everglades tree islands. In many of these islands, such restoration might involve supplementing tree stocking by planting native trees to produce more complete site utilization and a more open under story.

  2. High accuracy determination of trace elements in NIST standard reference materials by isotope dilution ICP-MS

    International Nuclear Information System (INIS)

    Paulsen, P.J.; Beary, E.S.

    1996-01-01

    At NIST (National Institute of Standards and Technology), ICP-MS ID (inductively coupled mass spectrometry isotope dilution) has been used to certify a wide range of elements in a variety of materials with high accuracy. Both the chemical preparation and instrumental procedures are simpler than with other ID mass spectrometric techniques. The ICP-MS has picogram/ml detection limits for most elements using fixed operating parameters. Chemical separations are required only to remove an interference (from molecular ions as well as isobaric atoms), or to pre-concentrate the analyte. For example, chemical separations were required for the analysis of SRM 2711, Montana II Soil, but not for boron in peach leaves, SRM 1547.(3 refs., 3 tabs., 2 figs

  3. MRI-tracking of transplanted human ASC in a SCID mouse model

    Energy Technology Data Exchange (ETDEWEB)

    Siegmund, Birte J.; Kasten, Annika [Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, Rostock University Medical Center (Germany); Kühn, Jens-Peter [Institute of Diagnostic Radiology and Neuroradiology, Greifswald University Medical Center (Germany); Winter, Karsten [Institute of Anatomy, Faculty of Medicine, University of Leipzig (Germany); Grüttner, Cordula [Micromod Partikeltechnologie GmbH, Rostock (Germany); Frerich, Bernhard, E-mail: bernhard.frerich@med.uni-rostock.de [Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, Rostock University Medical Center (Germany)

    2017-04-01

    Background: Regarding strategies improving the efficacy of stem cell transplantation in adipose tissue engineering, cell tracking might be useful. Here we report the in vivo tracking of adipose tissue derived stem cells (ASC) by means of nanoparticle labeling and magnetic resonance imaging (MRI). Here we report the in vivo tracking of adipose tissue derived stromal cells (ASC) by means of nanoparticle labeling and magnetic resonance imaging (MRI). Materials and methods: Human ASC were amplified and labeled with two types of magnetic nanoparticles (MNP), BNF starch and nanomag®-D-spio. Adipose tissue constructs were fabricated by seeding collagen scaffolds with labeled and unlabeled ASCs. Constructs were implanted subcutaneously in the back of severe combined immunodeficient (SCID) mice (n =69, group 1: control with cells w/o label, group 2: BNF starch labeled cells, group 3: nanomag®-D-spio labeled cells). MRI scans were performed at 24 hours, four, twelve and 28 days and four months in a 7.1 T animal device. Explanted constructs were analyzed histomorphometrically. Results: MRI scans showed high contrast of the labeled cells in t2-tse-sequence compared to unlabeled controls. Loss of volume of the implants was observed over time due to partial loss for transplanted cells without significant difference (level of significance p<0.017). Compared to histomorphometry, there was found a positiv correlations in measurement of implant size with a significant at day four (correlation coefficient =0.643; p=0.024) and day twelve (correlation coefficient =0.687; p=0.010). Additional Prussian blue stain showed iron in all implants. Significant differences between the three groups (significance level p<0.017) were found after twelve days between control group and group 3 (p=0.008) and after 28 days between control group and group 2 and 3 (p=0.011). Conclusion: Both MNPs might be suitable for tracking of ASC in vivo and show long term stability over 4 months. - Highlights:

  4. Antidepressant-Like Effects of Central BDNF Administration in Mice of Antidepressant Sensitive Catalepsy (ASC) Strain.

    Science.gov (United States)

    Tikhonova, Maria; Kulikov, Alexander V

    2012-08-31

    Although numerous data evidence the implication of brain-derived neurotrophic factor (BDNF) in the pathophysiology of depression, the potential for BDNF to correct genetically defined depressive-like states is poorly studied. This study was aimed to reveal antidepressant-like effects of BDNF (300 ng, 2×, i.c.v.) on behavior and mRNA expression of genes associated with depression-like state in the brain in mice of antidepressant sensitive catalepsy (ASC) strain characterized by high hereditary predisposition to catalepsy and depressive-like features. Behavioral tests were held on the 7th-16th days after the first (4th-13th after the second) BDNF injection. Results showed that BDNF normalized impaired sexual motivation in the ASC males, and this BDNF effect differed, with advantageous effects, from that of widely used antidepressants. The anticataleptic effect of two BDNF injections was enhanced compared with a single administration. A tendency to decrease the immobility duration in tail-suspension test was observed in BDNF-treated ASC mice. The effects on catalepsy and sexual motivation were specific since BDNF did not alter locomotor and exploratory activity or social interest in the ASC mice. Along with behavioral antidepressant-like effects on the ASC mice, BDNF increased hippocampal mRNA levels of Bdnf and Creb1 (cAMP response element-binding protein gene). BDNF also augmented mRNA levels of Arc gene encoding Arc (Activity-regulated cytoskeleton-associated) protein involved in BDNF-induced processes of neuronal and synaptic plasticity in hippocampus and prefrontal cortex. The data suggest that: [1] BDNF is effective in the treatment of some genetically defined behavioral disturbances; [2] BDNF influences sexually-motivated behavior; [3] Arc mRNA levels may serve as a molecular marker of BDNF physiological activity associated with its long-lasting behavioral effects; [4] ASC mouse strain can be used as a suitable model to study mechanisms of BDNF effects on

  5. [Effects of chronic fluoxetine treatment on manifestation of sexual motivation and social behavior in mice of ASC line].

    Science.gov (United States)

    Tikhonova, M A; Otroshchenko, E A; Kulikov, A V

    2010-02-01

    Sexual dysfunctions are the typical symptoms accompanying depressive disorders. However antidepressants which improve general state of the patients have no effect on sexual disorders. Mice of ASC (Antidepressant Sensitive Catalepsy) line with high hereditary predisposition to catalepsy were proposed as a model of genetically associated depressive-like condition. The work was aimed at comparison of behavioral indices of sexual motivation and social interest of ASC mice with those of mice of parental inbred AKR and CBA strains, and at the study of the effects of chronic fluoxetine treatment in doses of 10 and 20 mg/kg on these parameters in ASC mice. ASC males demonstrated reduced sexual motivation which was not corrected by fluoxetine. ASC mice did not differ in the expression of social interest and aggression towards juvenile intruder from mice of parental strains. Fluoxetine failed to alter social behavior of ASC mice in social interaction test but its higher dose decreased percentage of aggressors. ASC mouse line seems to be a perspective model to study genetic mechanisms of sexual dysfunctions associated with depressive conditions.

  6. In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter.

    Science.gov (United States)

    Malusek, A; Helmrot, E; Sandborg, M; Grindborg, J-E; Carlsson, G Alm

    2014-12-07

    The air kerma-area product (KAP) is used for settings of diagnostic reference levels. The International Atomic Energy Agency (IAEA) recommends that doses in diagnostic radiology (including the KAP values) be estimated with an accuracy of at least ± 7% (k = 2). Industry standards defined by the International Electrotechnical Commission (IEC) specify that the uncertainty of KAP meter measurements should be less than ± 25% (k = 2). Medical physicists willing to comply with the IAEA's recommendation need to apply correction factors to KAP values reported by x-ray units. The aim of this work is to present and evaluate a calibration method for built-in KAP meters on clinical x-ray units. The method is based on (i) a tandem calibration method, which uses a reference KAP meter calibrated to measure the incident radiation, (ii) measurements using an energy-independent ionization chamber to correct for the energy dependence of the reference KAP meter, and (iii) Monte Carlo simulations of the beam quality correction factors that correct for differences between beam qualities at a standard laboratory and the clinic. The method was applied to the KAP meter in a Siemens Aristos FX plus unit. It was found that values reported by the built-in KAP meter differed from the more accurate values measured by the reference KAP meter by more than 25% for high tube voltages (more than 140 kV) and heavily filtered beams (0.3 mm Cu). Associated uncertainties were too high to claim that the IEC's limit of 25% was exceeded. Nevertheless the differences were high enough to justify the need for a more accurate calibration of built-in KAP meters.

  7. Agreement between gastrointestinal panel testing and standard microbiology methods for detecting pathogens in suspected infectious gastroenteritis: Test evaluation and meta-analysis in the absence of a reference standard.

    Science.gov (United States)

    Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James

    2017-01-01

    Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.

  8. Anti-allergic activity of standardized extract of Albizia lebbeck with reference to catechin as a phytomarker.

    Science.gov (United States)

    Venkatesh, Pichairajan; Mukherjee, Pulok K; Kumar, Nanjappan Satheesh; Bandyopadhyay, Arun; Fukui, Hiroyuki; Mizuguchi, Hiroyuki; Islam, Nurul

    2010-06-01

    The major groups of phytonutrients found in plants include polyphenols, flavonoids, terpenes, amines, etc., all of which are observed to have potential anti-allergic activity. In this study, we evaluated the anti-allergic activity of the standardized extract of Albizia lebbeck with respect to the catechin, a polyphenolic phytomarker. The percentage of catechin in the ethanolic extract was found to be 14.72 mg/g. We administered Albizia lebbeck (50-300 mg/kg) and 50 mg/kg of catechin to mice to evaluate the mast cell stabilization and estimation of histamine elevation in the plasma. Results support the conclusion that Albizia lebbeck at different concentrations has got potent mast cell stabilizing property and the IC(50) value of Albizia lebbeck was found to be 85 microg/ml. This inhibitory potential of catechin from Albizia lebbeck is perhaps due to modulation of two important effector's functions, histamine release and cytokine expression of antigen -IgE activated mast cells.

  9. NBS SRM 1569 Brewer's Yeast: Is it an adequate standard reference material for testing a chromium determination in biological materials tion in biological materials

    International Nuclear Information System (INIS)

    Goeij, J.J.M. de; Volkers, K.J.; Tjioe, P.S.; Kroon, J.J.

    1978-01-01

    Some analytical experiences with NBS SRM 1569 Brewer's Yeast are presented. Against this background the adequacy of this standard reference material for the determination of chromium in biological materials is discussed. Authors have three main objections. Due to its high content of insoluble chromium-containing particles, SRM 1569 is not typical for biological materials, possibly not even for Brewer's Yeast. The chromium level of SRM 1569 is not typical for the chromium levels normally encountered in pure biological materials. The major fraction (69 +- 3 percent) of the chromium is present in a form which is insoluble under the conditions used in Author's analysis. (T.I.)

  10. HYGIEN AND TECHNOLOGY OF SMOKED SALMON’S PRODUCTION: COMPARISON BETWEEN STANDARD HEALTLY REFERENCE OF EUROPEAN LEGISLATION AND AN EXTRACOMUNITY ONE

    Directory of Open Access Journals (Sweden)

    E.M. Mannocchi

    2013-02-01

    Full Text Available The work makes a comparison between European and Switzerland legislation through an inspection in an artisan producing smoked salmon factory. The analysis of HACCP plan, technology and microbiological characteristic of finished product, as enshrined in Switzerland law, allow to categorize the business risk level respect the European reference. The criticalities detected are: Listeria monocytogenes and Anisakis spp.. A plain was developed for improving the hygienic characteristic of the production to ensure the alignment of structure to the standards specified by the European requirements and allow to the factory send his products inside the European market.

  11. Assessment of stability of trace elements in two natural matrix environmental standard reference materials. NIST-SRM 1547 Peach leaves and NIST-SRM 1566a Oyster Tissue

    International Nuclear Information System (INIS)

    Mackey, E.A.; Spatz, R.O.

    2009-01-01

    The NIST program for environmental Standard Reference Materials (SRM) includes materials covering a range of matrices, mass fraction values and analytes. For many SRMs, mass fraction data are accumulated, incidentally, over time, as these are used routinely for quality assurance purposes. Although these are not formal stability studies, data generated may be useful in assessing stability. To evaluate the potential for assessing material stability from incidental use of SRMs, results of neutron activation analysis performed from 1992 through 2008 were compiled for SRM 1547 Peach Leaves and SRM 1566a Oyster Tissue. Results indicate that incidental use of SRMs yields useful information on SRM stability. (author)

  12. Over-expression, purification and characterization of an Asc-1 homologue from Gloeobacter violaceus

    DEFF Research Database (Denmark)

    Wang, Xiaole; Hald, Helle; Ernst, Heidi Asschenfeldt

    2010-01-01

    The human alanine-serine-cysteine transporter 1 (Asc-1) belongs to the slc7a family of solute carrier transporters. Asc-1 mediates the uptake of D-serine in an exchanger-type fashion, coupling the process to the release of alanine and cysteine. Among the bacterial Asc-1 homologues, one transporter...... of auto-induction was crucial for obtaining high yields and purity of the transporter. The transporter was purified with yields in the range of 0.2-0.4 mg per L culture and eluted in a single peak from a size-exclusion column. The circular dichroism spectrum revealed a folded and apparently all...

  13. Development of a certified reference material for composition of high-purity copper as a transfer standard within GET 176-2013

    Directory of Open Access Journals (Sweden)

    Veniamin M. Zyskin

    2017-01-01

    Full Text Available Introduction. The paper gives information on the development of a certified reference material (CRM for composition of high-purity copper (Cu CRM UNIIM. The CRM is included as the transfer standard into the State primary standard of the mass (molar fraction and mass (molar concentration of the component in liquid and solid substances and materials based on coulometry GET 176-2013.Materials and methods. The CRM represents pieces of oxygen-free copper wire rod, brand KMB, produced according to GOST R 53803-2010, weighing from 0.5 to 1g. The CRM is packed in plastic vials with the capacity of 30 or 50 cm3. The certified characteristic of the CRM is copper mass fraction in copper wire rod, expressed in percentages. The certified value for copper mass fraction was established by the primary method of controlled-potential coulometry using the State primary standard GET 176-2013.Results. The permitted interval of the certified value for copper mass fraction in the CRM is from 99,950 % to 100,000 %. The relative expanded uncertainty (k=2 of the certified value for copper mass fraction does not exceed 0,030 %; the relative standard uncertainty due to inhomogeneity does not exceed 0.010 %; the relative standard uncertainty due to instability does not exceed 0.010 %. The shelf life of the developed CRM is 10 years provided that standard storage conditions are ensured.Discussion and conclusions. The developed CRM is included into the State register of type approved RMs under the number GSO 10800-2016. The CRM of high-purity copper (Cu CRM UNIIM as a transfer standard is intended for reproduction, storage and transfer of the copper mass fraction unit to other reference materials and chemical reagents by the method of comparison using a comparator and by conducting direct measurements. This CRM may also be used:– for verification of measuring instruments (MIs according to the state verification schedule described in GOST R 8.735.0-2014,– for calibration

  14. ASC Tri-lab Co-design Level 2 Milestone Report 2015

    Energy Technology Data Exchange (ETDEWEB)

    Hornung, Rich [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Jones, Holger [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Keasler, Jeff [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Neely, Rob [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pearce, Olga [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hammond, Si [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Trott, Christian [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lin, Paul [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vaughan, Courtenay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Cook, Jeanine [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hoekstra, Rob [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bergen, Ben [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Payne, Josh [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Womeldorff, Geoff [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-09-23

    In 2015, the three Department of Energy (DOE) National Laboratories that make up the Advanced Sci- enti c Computing (ASC) Program (Sandia, Lawrence Livermore, and Los Alamos) collaboratively explored performance portability programming environments in the context of several ASC co-design proxy applica- tions as part of a tri-lab L2 milestone executed by the co-design teams at each laboratory. The programming environments that were studied included Kokkos (developed at Sandia), RAJA (LLNL), and Legion (Stan- ford University). The proxy apps studied included: miniAero, LULESH, CoMD, Kripke, and SNAP. These programming models and proxy-apps are described herein. Each lab focused on a particular combination of abstractions and proxy apps, with the goal of assessing performance portability using those. Performance portability was determined by: a) the ability to run a single application source code on multiple advanced architectures, b) comparing runtime performance between \

  15. Effects of Metal Micro and Nano-Particles on hASCs: An In Vitro Model

    OpenAIRE

    Palombella, Silvia; Pirrone, Cristina; Rossi, Federica; Armenia, Ilaria; Cherubino, Mario; Valdatta, Luigi; Raspanti, Mario; Bernardini, Giovanni; Gornati, Rosalba

    2017-01-01

    As the knowledge about the interferences of nanomaterials on human staminal cells are scarce and contradictory, we undertook a comparative multidisciplinary study based on the size effect of zero-valent iron, cobalt, and nickel microparticles (MPs) and nanoparticles (NPs) using human adipose stem cells (hASCs) as a model, and evaluating cytotoxicity, morphology, cellular uptake, and gene expression. Our results suggested that the medium did not influence the cell sensitivity but, surprisingly...

  16. Intracellular invasion of Orientia tsutsugamushi activates inflammasome in asc-dependent manner.

    Directory of Open Access Journals (Sweden)

    Jung-Eun Koo

    Full Text Available Orientia tsutsugamushi, a causative agent of scrub typhus, is an obligate intracellular bacterium, which escapes from the endo/phagosome and replicates in the host cytoplasm. O. tsutsugamushi infection induces production of pro-inflammatory mediators including interleukin-1β (IL-1β, which is secreted mainly from macrophages upon cytosolic stimuli by activating cysteine protease caspase-1 within a complex called the inflammasome, and is a key player in initiating and maintaining the inflammatory response. However, the mechanism for IL-1β maturation upon O. tsutsugamushi infection has not been identified. In this study, we show that IL-1 receptor signaling is required for efficient host protection from O. tsutsugamushi infection. Live Orientia, but not heat- or UV-inactivated Orientia, activates the inflammasome through active bacterial uptake and endo/phagosomal maturation. Furthermore, Orientia-stimulated secretion of IL-1β and activation of caspase-1 are ASC- and caspase-1- dependent since IL-1β production was impaired in Asc- and caspase-1-deficient macrophages but not in Nlrp3-, Nlrc4- and Aim2-deficient macrophages. Therefore, live O. tsutsugamushi triggers ASC inflammasome activation leading to IL-1β production, which is a critical innate immune response for effective host defense.

  17. Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) with Standard Reference Line for the Analysis of Stainless Steel.

    Science.gov (United States)

    Fu, Hongbo; Dong, Fengzhong; Wang, Huadong; Jia, Junwei; Ni, Zhibo

    2017-08-01

    In this work, calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is used to analyze a certified stainless steel sample. Due to self-absorption of the spectral lines from the major element Fe and the sparse lines of trace elements, it is usually not easy to construct the Boltzmann plots of all species. A standard reference line method is proposed here to solve this difficulty under the assumption of local thermodynamic equilibrium so that the same temperature value for all elements present into the plasma can be considered. Based on the concentration and rich spectral lines of Fe, the Stark broadening of Fe(I) 381.584 nm and Saha-Boltzmann plots of this element are used to calculate the electron density and the plasma temperature, respectively. In order to determine the plasma temperature accurately, which is seriously affected by self-absorption, a pre-selection procedure for eliminating those spectral lines with strong self-absorption is employed. Then, one spectral line of each element is selected to calculate its corresponding concentration. The results from the standard reference lines with and without self-absorption of Fe are compared. This method allows us to measure trace element content and effectively avoid the adverse effects due to self-absorption.

  18. Effect of polytetrafluoroethylene (PTFE) phase transition at 19°C on the use of Spectralon as a reference standard for reflectance.

    Science.gov (United States)

    Ball, Christopher P; Levick, Andrew P; Woolliams, Emma R; Green, Paul D; Dury, Martin R; Winkler, Rainer; Deadman, Andrew J; Fox, Nigel P; King, Martin D

    2013-07-10

    Sintered polytetrafluoroethylene (PTFE) is highly reflective and is widely used as a reference standard in remote sensing, radiometry, and spectroscopy. The relative change in output flux from a PTFE integrating sphere over the room temperature phase transition at 19°C has been measured at a monochromatic wavelength of 633 nm as 1.82±0.21%. The change in output flux was attributed to a small change of 0.09±0.02% in the total hemispherical reflectance of PTFE, caused by a change in its material density as a result of the phase transition. For the majority of users, this small change measured in total hemispherical reflectance is unlikely to impact significantly the accuracy of PTFE flat panel reflectors used as reference standards. However, owing to the multiple reflections that occur inside an integrating sphere cavity, the effect is multiplied and remedial action should be applied, either via a mathematical correction or through temperature stabilization of the integrating sphere when high accuracy (PTFE-based integrating spheres at temperatures close to the phase transition at 19°C.

  19. A novel strategy with standardized reference extract qualification and single compound quantitative evaluation for quality control of Panax notoginseng used as a functional food.

    Science.gov (United States)

    Li, S P; Qiao, C F; Chen, Y W; Zhao, J; Cui, X M; Zhang, Q W; Liu, X M; Hu, D J

    2013-10-25

    Root of Panax notoginseng (Burk.) F.H. Chen (Sanqi in Chinese) is one of traditional Chinese medicines (TCMs) based functional food. Saponins are the major bioactive components. The shortage of reference compounds or chemical standards is one of the main bottlenecks for quality control of TCMs. A novel strategy, i.e. standardized reference extract based qualification and single calibrated components directly quantitative estimation of multiple analytes, was proposed to easily and effectively control the quality of natural functional foods such as Sanqi. The feasibility and credibility of this methodology were also assessed with a developed fast HPLC method. Five saponins, including ginsenoside Rg1, Re, Rb1, Rd and notoginsenoside R1 were rapidly separated using a conventional HPLC in 20 min. The quantification method was also compared with individual calibration curve method. The strategy is feasible and credible, which is easily and effectively adapted for improving the quality control of natural functional foods such as Sanqi. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Revision of the SNPforID 34-plex forensic ancestry test: Assay enhancements, standard reference sample genotypes and extended population studies.

    Science.gov (United States)

    Fondevila, M; Phillips, C; Santos, C; Freire Aradas, A; Vallone, P M; Butler, J M; Lareu, M V; Carracedo, A

    2013-01-01

    A revision of an established 34 SNP forensic ancestry test has been made by swapping the under-performing rs727811 component SNP with the highly informative rs3827760 that shows a near-fixed East Asian specific allele. We collated SNP variability data for the revised SNP set in 66 reference populations from 1000 Genomes and HGDP-CEPH panels and used this as reference data to analyse four U.S. populations showing a range of admixture patterns. The U.S. Hispanics sample in particular displayed heterogeneous values of co-ancestry between European, Native American and African contributors, likely to reflect in part, the way this disparate group is defined using cultural as well as population genetic parameters. The genotyping of over 700 U.S. population samples also provided the opportunity to thoroughly gauge peak mobility variation and peak height ratios observed from routine use of the single base extension chemistry of the 34-plex test. Finally, the genotyping of the widely used DNA profiling Standard Reference Material samples plus other control DNAs completes the audit of the 34-plex assay to allow forensic practitioners to apply this test more readily in their own laboratories. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Comparing the role of standard references on the prevalence of Iranian children and adolescents' overweight and obesity: A systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Saeed Ghanbari

    2016-01-01

    Full Text Available Background: Obesity is a major risk factor for chronic diseases and has a role on high blood pressure, diabetes type II, etc., This review assesses the prevalence of Iranian children obesity and overweight for different age categories and compares the three standard definitions of obesity. Materials and Methods: To retrieve desirable studies concerning childhood anthropometric data from different area of Iran, the MEDLINE, Scopus, and different local databases such as Scientific Information database were used. The studies reported the prevalence of obesity or overweight of children < 6, 6–12, and 12–20 years old, despite differences between definitions of childhood obesity, were included in the study. We combined the reported prevalence of the overweight and obesity with regard to age and gender, and also by the different standard references which are the Centers for Disease Control and Prevention (CDC, the World Health Organization (WHO definition, and the International Obesity Task Force (IOTF references. The analysis was carried out using STATA software. Results: Our review covered 75 articles reported the prevalence of overweight or obesity among children and adolescents for different age groups in Iran. Our meta-regression analysis showed that the prevalence of obesity and overweight did not vary significantly in gender and age categories, but different definitions provide different prevalence of overweight and obesity. Conclusion: The effective factors on obesity and overweight included administration policy and organizational, interpersonal, intrapersonal, and social factors. CDC and WHO references intended in monitoring children's growth and the IOTF cutoffs would rather provide a common set of definitions that researchers and policymakers could use for descriptive and comparative purposes.

  2. Repair of Achilles tendon defect with autologous ASCs engineered tendon in a rabbit model.

    Science.gov (United States)

    Deng, Dan; Wang, Wenbo; Wang, Bin; Zhang, Peihua; Zhou, Guangdong; Zhang, Wen Jie; Cao, Yilin; Liu, Wei

    2014-10-01

    Adipose derived stem cells (ASCs) are an important cell source for tissue regeneration and have been demonstrated the potential of tenogenic differentiation in vitro. This study explored the feasibility of using ASCs for engineered tendon repair in vivo in a rabbit Achilles tendon model. Total 30 rabbits were involved in this study. A composite tendon scaffold composed of an inner part of polyglycolic acid (PGA) unwoven fibers and an outer part of a net knitted with PGA/PLA (polylactic acid) fibers was used to provide mechanical strength. Autologous ASCs were harvested from nuchal subcutaneous adipose tissues and in vitro expanded. The expanded ASCs were harvested and resuspended in culture medium and evenly seeded onto the scaffold in the experimental group, whereas cell-free scaffolds served as the control group. The constructs of both groups were cultured inside a bioreactor under dynamic stretch for 5 weeks. In each of 30 rabbits, a 2 cm defect was created on right side of Achilles tendon followed by the transplantation of a 3 cm cell-seeded scaffold in the experimental group of 15 rabbits, or by the transplantation of a 3 cm cell-free scaffold in the control group of 15 rabbits. Animals were sacrificed at 12, 21 and 45 weeks post-surgery for gross view, histology, and mechanical analysis. The results showed that short term in vitro culture enabled ASCs to produce matrix on the PGA fibers and the constructs showed tensile strength around 50 MPa in both groups (p > 0.05). With the increase of implantation time, cell-seeded constructs gradually form neo-tendon and became more mature at 45 weeks with histological structure similar to that of native tendon and with the presence of bipolar pattern and D-periodic structure of formed collagen fibrils. Additionally, both collagen fibril diameters and tensile strength increased continuously with significant difference among different time points (p tendon tissue with fibril structure observable only at 45 weeks

  3. Detection of heart rate and rhythm with a smartphone-based electrocardiograph versus a reference standard electrocardiograph in dogs and cats.

    Science.gov (United States)

    Kraus, Marc S; Gelzer, Anna R; Rishniw, Mark

    2016-07-15

    OBJECTIVE To evaluate the diagnostic utility of ECGs acquired with a smartphone-based device, compared with reference 6-lead ECGs, for identification of heart rate and rhythm in dogs and cats. DESIGN Prospective study. ANIMALS 51 client-owned dogs and 27 client-owned cats. PROCEDURES Patients examined by a small animal referral cardiology service between April 2012 and January 2013 were enrolled consecutively. In each patient, a 30-second ECG was simultaneously acquired with a smartphone-based device (a bipolar, single-lead recorder coupled to a smartphone with an ECG application) and a standard 6-lead ECG machine. Recordings were evaluated by 3 board-certified cardiologists, and intra- and interobserver agreement were evaluated for both rhythm diagnosis and QRS polarity identification. RESULTS Values for instantaneous and mean heart rates for the smartphone-acquired and reference ECGs were within 1 beat of each other when mean heart rates were calculated. Intraobserver agreement for rhythm assessment was very high, with maximum disagreement for any observer for only 2 of 51 dogs and only 4 of 27 cats. There was minimal disagreement in the polarity of depolarization between the smartphone-acquired and reference ECGs in dogs but frequent disagreement in cats. Interobserver agreement for smartphone-acquired ECGs was similar to that for reference ECGs. with all 3 observers agreeing on the rhythm analysis and minimal disagreement on polarity. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that ECGs acquired with the smartphone-based device accurately identified heart rate and rhythm in dogs and cats. Thus, the device may allow veterinarians to evaluate and manage cardiac arrhythmias relatively inexpensively at the cage side and could also allow clinicians to rapidly share information via email for further consultation, potentially enhancing patient care.

  4. Recent references

    International Nuclear Information System (INIS)

    Ramavataram, S.

    1991-01-01

    In support of a continuing program of systematic evaluation of nuclear structure data, the National Nuclear Data Center maintains a complete computer file of references to the nuclear physics literature. Each reference is tagged by a keyword string, which indicates the kinds of data contained in the article. This master file of Nuclear Structure References (NSR) contains complete keyword indexes to literature published since 1969, with partial indexing of older references. Any reader who finds errors in the keyword descriptions is urged to report them to the National Nuclear Data Center so that the master NSR file can be corrected. In 1966, the first collection of Recent References was published as a separate issue of Nuclear Data Sheets. Every four months since 1970, a similar indexed bibliography to new nuclear experiments has been prepared from additions to the NSR file and published. Beginning in 1978, Recent References was cumulated annually, with the third issue completely superseding the two issues previously published during a given year. Due to publication policy changes, cumulation of Recent Reference was discontinued in 1986. The volume and issue number of all the cumulative issues published to date are given. NNDC will continue to respond to individual requests for special bibliographies on nuclear physics topics, in addition to those easily obtained from Recent References. If the required information is available from the keyword string, a reference list can be prepared automatically from the computer files. This service can be provided on request, in exchange for the timely communication of new nuclear physics results (e.g., preprints). A current copy of the NSR file may also be obtained in a standard format on magnetic tape from NNDC. Requests for special searches of the NSR file may also be directed to the National Nuclear Data Center

  5. Standard Reference Line Combined with One-Point Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) to Quantitatively Analyze Stainless and Heat Resistant Steel.

    Science.gov (United States)

    Fu, Hongbo; Wang, Huadong; Jia, Junwei; Ni, Zhibo; Dong, Fengzhong

    2018-01-01

    Due to the influence of major elements' self-absorption, scarce observable spectral lines of trace elements, and relative efficiency correction of experimental system, accurate quantitative analysis with calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is in fact not easy. In order to overcome these difficulties, standard reference line (SRL) combined with one-point calibration (OPC) is used to analyze six elements in three stainless-steel and five heat-resistant steel samples. The Stark broadening and Saha - Boltzmann plot of Fe are used to calculate the electron density and the plasma temperature, respectively. In the present work, we tested the original SRL method, the SRL with the OPC method, and intercept with the OPC method. The final calculation results show that the latter two methods can effectively improve the overall accuracy of quantitative analysis and the detection limits of trace elements.

  6. Substoichiometric isotope dilution analysis of arsenic in biological and environmental standard reference materials by solvent extraction using toluene-3,4-dithiol in benzene

    International Nuclear Information System (INIS)

    Chutke, N.L.; Ambulkar, Ms.M.N.; Weginwar, R.G.; Garg, A.N.

    1994-01-01

    A radiochemical solvent extraction procedure has been developed for the determination of As(III) using 76 As tracer. It is based on the complexation of As(III) with toluene-3,4-dithiol (TDT) at pH 2 and subsequent extraction in benzene. The effect of various parameters such as pH, time of equilibration, nature of solvent, quantitative character and interferences have been studied. The method has been further developed into substoichiometric isotope dilution analysis for the determination of As at < 1μg level and employed for the analysis of several environmental and biological standard Reference Materials from NIST (USA), IAEA (Vienna) and NIES (Japan). (author) 39 refs.; 4 figs.; 4 tabs

  7. Reference standards for quantitative trace analysis of PCB's by GC. Technical PCB formulations for the calibration of ECD and MSD responses

    Energy Technology Data Exchange (ETDEWEB)

    Krupcik, J. (Slovak Technical Univ., Department of Analytical Chemistry, Bratislava (Slovakia)); Kocan, A. (Institute of Preventive Medicine, Bratislava (Slovakia)); Petrik, J. (Institute of Preventive Medicine, Bratislava (Slovakia)); Leclercq, P.A. (Eindhoven University of Technology, Dept. of Chemical Engineering, Lab. of Instrumental Analysis (Netherlands)); Ballschmiter, K. (University of Ulm, Dept. of Analytical and Environmental Chemistry (Germany))

    1993-04-01

    The composition of any technical PCB formulation can be determined directly by analyzing the PCB sample by gas chromatography with a flame ionization detector (GC-FID), provided the relative molecular masses of the components are known. The response of electron capture and selected-ion monitoring, mass-spectra detectors can then be calibrated for individual PCB congeners by correlation of the chromatographic patterns with those of concentrated PCB samples obtained by GC-FID. This procedure, which uses a given technical PCB formulation as a secondary reference standard mixture, is to be preferred over existing calibration methods, when results with [+-]10% errors are acceptable because commercial PCB formulations cover the whole range of chlorination products. (orig.)

  8. Added value of cardiac computed tomography for evaluation of mechanical aortic valve: Emphasis on evaluation of pannus with surgical findings as standard reference.

    Science.gov (United States)

    Suh, Young Joo; Lee, Sak; Im, Dong Jin; Chang, Suyon; Hong, Yoo Jin; Lee, Hye-Jeong; Hur, Jin; Choi, Byoung Wook; Chang, Byung-Chul; Shim, Chi Young; Hong, Geu-Ru; Kim, Young Jin

    2016-07-01

    The added value of cardiac computed tomography (CT) with transesophageal echocardiography (TEE) for evaluating mechanical aortic valve (AV) dysfunction has not yet been investigated. The purposes of this study were to investigate the added value of cardiac CT for evaluation of mechanical AVs and diagnoses of pannus compared to TEE, with surgical findings of redo-aortic valve replacement (AVR) used as a standard reference. 25 patients who underwent redo-AVR due to mechanical AV dysfunction and cardiac CT before redo-AVR were included. The presence of pannus, encroachment ratio by pannus, and limitation of motion (LOM) were evaluated on CT. The diagnostic performance of pannus detection was compared using TEE, CT, and CT+TEE, with surgical findings as a standard reference. The added value of CT for diagnosing the cause of mechanical AV dysfunction was assessed compared to TTE+TEE. In two patients, CT analysis was not feasible due to severe metallic artifacts. On CT, pannus and LOM were found in 100% (23/23) and 60.9% (14/23). TEE identified pannus in 48.0% of patients (12/25). CT, TEE, and CT+TEE correctly identified pannus with sensitivity of 92.0%, 48.0%, and 92.0%, respectively (P=0.002 for CT vs. TEE). In 11 of 13 cases (84.6%) with inconclusive or negative TEE results for pannus, CT detected the pannus. Among 13 inconclusive cases of TTE+TEE for the cause of mechanical AV dysfunction, CT suggested 6 prosthetic valve obstruction (PVO) by pannus, 4 low-flow low-gradient PVO, and one LOM without significant PVO. Cardiac CT showed added diagnostic value with TEE in the detection of pannus as the cause of mechanical AV dysfunction. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Quantification of pneumothorax volume on chest radiographs: comparison between the collins' and the axel's methods with three-dimensional CT as the standard of reference

    International Nuclear Information System (INIS)

    Lee, Chang Keun; Kim, Hyung Jin; Lee, Kyung Hee; Kim, Joung Taek; Kim, Kwang Ho; Suh, Chang Hae; Han, Heon

    1999-01-01

    The purpose of this study was twofold. In a preliminary study, we evaluated the accuracy of 3-D (three-dimensional) CT for the estimation of pneumothorax volume and for providing the optimal postprocessing method for clinical study. In the clinical study, we determined which of the two methods, Collins' and Axel's, was more accurate for the estimation of pneumothorax volume, as seen on chest radiographs, using 3-D CT as the standard of reference. In the preliminary study, 3-D CT was applied to phantoms and to four patients with pneumothorax using two different postprocessing methods, manual contour delineation and thresholding. In the clinical study, 3-D CT was performed in 13 patients with pneumothorax. For the purpose of evaluating conventional radiographs, a localizer scan was used for comparing the accuracy of Collins' method with that of Axel's method, with 3-D CT as the standard of reference. The preliminary study revealed that 3-D CT estimated pneumothorax volume with great accuracy and that manual contour delineation and thresholding measured volume equally well. Because of the shorter postprocessing time required with thresholding than with manual contour delineation (5 min versus 30 min), the former was used during clinical study. The results of this indicated close correlation between the measurements obtained using Collins' method on chest radiographs and those obtained by 3-D CT(r=0.95, p 0.05). 3-D CT can estimate pneumothorax volume with great accuracy. Collins' method is superior to Axel's method for the quantification of pneumothorax volume as seen on chest radiographs

  10. Use of fat mass and fat free mass standard deviation scores obtained using simple measurement methods in healthy children and patients: comparison with the reference 4-component model.

    Science.gov (United States)

    Atherton, Rachel R; Williams, Jane E; Wells, Jonathan C K; Fewtrell, Mary S

    2013-01-01

    Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2)/Z)) in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients). DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (± 0.62); FFM SDS -0.04 (± 0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.

  11. Use of fat mass and fat free mass standard deviation scores obtained using simple measurement methods in healthy children and patients: comparison with the reference 4-component model.

    Directory of Open Access Journals (Sweden)

    Rachel R Atherton

    Full Text Available BACKGROUND: Clinical application of body composition (BC measurements for individual children has been limited by lack of appropriate reference data. OBJECTIVES: (1 To compare fat mass (FM and fat free mass (FFM standard deviation scores (SDS generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C model; (2 To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. DESIGN: FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy, BMI and skinfold thicknesses (SFT; and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2/Z in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients. RESULTS: DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement FM SDS 0.03 (± 0.62; FFM SDS -0.04 (± 0.72, and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2. BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. CONCLUSIONS: DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.

  12. Antropometria de atletas culturistas em relação à referência populacional Anthropometry of body builders in relation to the population standard

    Directory of Open Access Journals (Sweden)

    Naílza MAESTÁ

    2000-08-01

    Full Text Available Atletas de culturismo têm como alvo de treinamento a hipertrofia muscular e a redução da adiposidade. A falta de referências antropométricas apropriadas pode levar esses indivíduos a serem erroneamente considerados em situação de sobrepeso ou desnutrição. Portanto, objetivamos comparar a composição corporal de atletas de culturismo com os padrões populacionais. Foram avaliados 36 atletas, de ambos os sexos, 26 do sexo masculino (27,2 ± 7,2 anos e 10 do sexo feminino (30,0 ± 6,1 anos, por ocasião da competição nacional, quanto aos indicadores antropométricos de peso, estatura, índice de massa corpórea, pregas cutâneas, adiposidade corpórea e circunferência muscular do braço. Os resultados foram referidos quanto à posição percentual ou de desvios-padrão (pelo escore Z tendo como referências padrões populacionais locais. Como resultado, encontramos que os indicadores com menor contraste com os padrões adotados foram peso e estatura e os maiores contrastes foram encontrados na circunferência muscular do braço para os homens, e pregas cutâneas tricipital para as mulheres. Pelo indicador muscular todos foram classificados como obesos ou sobrepeso, enquanto que pela prega cutânea tricipital e adiposidade corpórea, a desnutrição esteve presente em 100,0% das mulheres e 88,5% dos homens. Fica evidenciada a inadequação da utilização do padrão antropométrico populacional para a classificação nutricional de atletas de força, em particular culturistas, sendo assim necessário o estabelecimento de padrões próprios para esse tipo de treinamento (modalidade.Body builders have as their training goals the maximum muscle hypertrophy with minimum adiposity. However, the scarcity of specific standards implies often in framing wrongly those athletes either as overweight (by their BMI or energy malnourished (by their fat stores. The objective of this study was to compare the body composition of body builders with

  13. ['Gold standard', not 'golden standard'

    NARCIS (Netherlands)

    Claassen, J.A.H.R.

    2005-01-01

    In medical literature, both 'gold standard' and 'golden standard' are employed to describe a reference test used for comparison with a novel method. The term 'gold standard' in its current sense in medical research was coined by Rudd in 1979, in reference to the monetary gold standard. In the same

  14. The Clinical Utility of ASRS-v1.1 for Identifying ADHD in Alcoholics Using PRISM as the Reference Standard.

    Science.gov (United States)

    Reyes, Maria M; Schneekloth, Terry D; Hitschfeld, Mario J; Geske, Jennifer R; Atkinson, David L; Karpyak, Victor M

    2016-05-02

    The objective was to assess the clinical utility of the Adult ADHD Self-Report Scale (ASRS-v1.1) in identifying ADHD in alcoholics using the Psychiatric Research Interview for Substance and Mental Disorders (PRISM) as the diagnostic "gold standard." We performed a secondary analysis of data from 379 treatment-seeking alcoholics who completed the ASRS-v1.1 and the ADHD module of the PRISM. Data analysis included descriptive statistics. The prevalence of ADHD was 7.7% (95% CI = [5.4, 10.8]). The positive predictive value (PPV) of the ASRS-v1.1 was 18.1% (95% CI = [12.4, 25.7]) and the negative predictive value (NPV) was 97.6% (95% CI = [94.9, 98.9]). The ASRS-v1.1 demonstrated a sensitivity of 79.3% (95% CI = [61.6, 90.2]) and a specificity of 70.3% (95% CI = [65.3, 74.8]). The ASRS-v1.1 demonstrated acceptable sensitivity and specificity in a sample of treatment-seeking alcoholics when compared with the PRISM as the reference standard for ADHD diagnosis. © The Author(s) 2016.

  15. Isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS) for the certification of lead and cadmium in environmental standard reference materials.

    Science.gov (United States)

    Murphy, K E; Beary, E S; Rearick, M S; Vocke, R D

    2000-10-01

    Lead (Pb) and cadmium (Cd) have been determined in six new environmental standard reference materials (SRMs) using isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS). The SRMs are the following: SRM 1944, New York-New Jersey Waterway Sediment, SRMs 2583 and 2584, Trace Elements in Indoor Dust, Nominal 90 mg/kg and 10,000 mg/kg Lead, respectively, SRMs 2586 and 2587, Trace Elements in Soil Containing Lead from Paint, Nominal 500 mg/kg and 3,000 mg/kg Lead, respectively, and SRM 2782, Industrial Sludge. The capabilities of ID ICP-MS for the certification of Pb and Cd in these materials are assessed. Sample preparation and ratio measurement uncertainties have been evaluated. Reproducibility and accuracy of the established procedures are demonstrated by determination of gravimetrically prepared primary standard solutions and by comparison with isotope dilution thermal ionization mass spectrometry (ID TIMS). Material heterogeneity was readily demonstrated to be the dominant source of uncertainty in the certified values.

  16. Bayesian modeling and inference for diagnostic accuracy and probability of disease based on multiple diagnostic biomarkers with and without a perfect reference standard.

    Science.gov (United States)

    Jafarzadeh, S Reza; Johnson, Wesley O; Gardner, Ian A

    2016-03-15

    The area under the receiver operating characteristic (ROC) curve (AUC) is used as a performance metric for quantitative tests. Although multiple biomarkers may be available for diagnostic or screening purposes, diagnostic accuracy is often assessed individually rather than in combination. In this paper, we consider the interesting problem of combining multiple biomarkers for use in a single diagnostic criterion with the goal of improving the diagnostic accuracy above that of an individual biomarker. The diagnostic criterion created from multiple biomarkers is based on the predictive probability of disease, conditional on given multiple biomarker outcomes. If the computed predictive probability exceeds a specified cutoff, the corresponding subject is allocated as 'diseased'. This defines a standard diagnostic criterion that has its own ROC curve, namely, the combined ROC (cROC). The AUC metric for cROC, namely, the combined AUC (cAUC), is used to compare the predictive criterion based on multiple biomarkers to one based on fewer biomarkers. A multivariate random-effects model is proposed for modeling multiple normally distributed dependent scores. Bayesian methods for estimating ROC curves and corresponding (marginal) AUCs are developed when a perfect reference standard is not available. In addition, cAUCs are computed to compare the accuracy of different combinations of biomarkers for diagnosis. The methods are evaluated using simulations and are applied to data for Johne's disease (paratuberculosis) in cattle. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Microwave-assisted versus conventional decomposition procedures applied to a ceramic potsherd standard reference material by inductively coupled plasma atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulou, D.N.; Zachariadis, G.A.; Anthemidis, A.N.; Tsirliganis, N.C.; Stratis, J.A

    2004-03-03

    Inductively coupled plasma atomic emission spectrometry (ICP-AES) is a powerful, sensitive analytical technique with numerous applications in chemical characterization including that of ancient pottery, mainly due to its multi-element character, and the relatively short time required for the analysis. A critical step in characterization studies of ancient pottery is the selection of a suitable decomposition procedure for the ceramic matrix. The current work presents the results of a comparative study of six decomposition procedures applied on a standard ceramic potsherd reference material, SARM 69. The investigated decomposition procedures included three microwave-assisted decomposition procedures, one wet decomposition (WD) procedure by conventional heating, one combined microwave-assisted and conventional heating WD procedure, and one fusion procedure. Chemical analysis was carried out by ICP-AES. Five major (Si, Al, Fe, Ca, Mg), three minor (Mn, Ba, Ti) and two trace (Cu, Co) elements were determined and compared with their certified values. Quantitation was performed at two different spectral lines for each element and multi-element matrix-matched calibration standards were used. The recovery values for the six decomposition procedures ranged between 75 and 110% with a few notable exceptions. Data were processed statistically in order to evaluate the investigated decomposition procedures in terms of recovery, accuracy and precision, and eventually select the most appropriate one for ancient pottery analysis.

  18. Antiproliferative effect of ASC-J9 delivered by PLGA nanoparticles against estrogen-dependent breast cancer cells.

    Science.gov (United States)

    Verderio, Paolo; Pandolfi, Laura; Mazzucchelli, Serena; Marinozzi, Maria Rosaria; Vanna, Renzo; Gramatica, Furio; Corsi, Fabio; Colombo, Miriam; Morasso, Carlo; Prosperi, Davide

    2014-08-04

    Among polymeric nanoparticles designed for cancer therapy, PLGA nanoparticles have become one of the most popular polymeric devices for chemotherapeutic-based nanoformulations against several kinds of malignant diseases. Promising properties, including long-circulation time, enhanced tumor localization, interference with "multidrug" resistance effects, and environmental biodegradability, often result in an improvement of the drug bioavailability and effectiveness. In the present work, we have synthesized 1,7-bis(3,4-dimethoxyphenyl)-5-hydroxyhepta-1,4,6-trien-3-one (ASC-J9) and developed uniform ASC-J9-loaded PLGA nanoparticles of about 120 nm, which have been prepared by a single-emulsion process. Structural and morphological features of the nanoformulation were analyzed, followed by an accurate evaluation of the in vitro drug release kinetics, which exhibited Fickian law diffusion over 10 days. The intracellular degradation of ASC-J9-bearing nanoparticles within estrogen-dependent MCF-7 breast cancer cells was correlated to a time- and dose-dependent activity of the released drug. A cellular growth inhibition associated with a specific cell cycle G2/M blocking effect caused by ASC-J9 release inside the cytosol allowed us to put forward a hypothesis on the action mechanism of this nanosystem, which led to the final cell apoptosis. Our study was accomplished using Annexin V-based cell death analysis, MTT assessment of proliferation, radical scavenging activity, and intracellular ROS evaluation. Moreover, the intracellular localization of nanoformulated ASC-J9 was confirmed by a Raman optical imaging experiment designed ad hoc. PLGA nanoparticles and ASC-J9 proved also to be safe for a healthy embryo fibroblast cell line (3T3-L1), suggesting a possible clinical translation of this potential nanochemotherapeutic to expand the inherently poor bioavailability of hydrophobic ASC-J9 that could be proposed for the treatment of malignant breast cancer.

  19. NLRP3 and ASC suppress lupus-like autoimmunity by driving the immunosuppressive effects of TGF-β receptor signalling.

    Science.gov (United States)

    Lech, Maciej; Lorenz, Georg; Kulkarni, Onkar P; Grosser, Marian O O; Stigrot, Nora; Darisipudi, Murthy N; Günthner, Roman; Wintergerst, Maximilian W M; Anz, David; Susanti, Heni Eka; Anders, Hans-Joachim

    2015-12-01

    The NLRP3/ASC inflammasome drives host defence and autoinflammatory disorders by activating caspase-1 to trigger the secretion of mature interleukin (IL)-1β/IL-18, but its potential role in autoimmunity is speculative. We generated and phenotyped Nlrp3-deficient, Asc-deficient, Il-1r-deficient and Il-18-deficient C57BL/6-lpr/lpr mice, the latter being a mild model of spontaneous lupus-like autoimmunity. While lack of IL-1R or IL-18 did not affect the C57BL/6-lpr/lpr phenotype, lack of NLRP3 or ASC triggered massive lymphoproliferation, lung T cell infiltrates and severe proliferative lupus nephritis within 6 months, which were all absent in age-matched C57BL/6-lpr/lpr controls. Lack of NLRP3 or ASC increased dendritic cell and macrophage activation, the expression of numerous proinflammatory mediators, lymphocyte necrosis and the expansion of most T cell and B cell subsets. In contrast, plasma cells and autoantibody production were hardly affected. This unexpected immunosuppressive effect of NLRP3 and ASC may relate to their known role in SMAD2/3 phosphorylation during tumour growth factor (TGF)-β receptor signalling, for example, Nlrp3-deficiency and Asc-deficiency significantly suppressed the expression of numerous TGF-β target genes in C57BL/6-lpr/lpr mice and partially recapitulated the known autoimmune phenotype of Tgf-β1-deficient mice. These data identify a novel non-canonical immunoregulatory function of NLRP3 and ASC in autoimmunity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Certification of total arsenic in blood and urine standard reference materials by radiochemical neutron activation analysis and inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Paul, R.L.; Clay Davis, W.; Lee Yu; Murphy, K.E.; Bryan, C.E.; Vetter, T.W.; Guthrie, W.F.; Leber, D.D.; Gulchekhra Shakirova; Graylin Mitchell

    2014-01-01

    Radiochemical neutron activation analysis (RNAA) was used to measure arsenic at four levels in standard reference material (SRM) 955c Toxic Elements in Caprine Blood and at two levels in SRM 2668 Toxic Elements in Frozen Human Urine for the purpose of providing mass concentration values for certification. Samples were freeze-dried prior to analysis followed by neutron irradiation for 3 h at a fluence rate of 1 × 10 14 cm -2 s -1 . After sample dissolution in perchloric and nitric acids, arsenic was separated from the matrix either by retention on hydrated manganese dioxide (urine) or by extraction into zinc diethyldithiocarbamate in chloroform (blood). 76 As was quantified by gamma-ray spectroscopy. Differences in chemical yield and counting geometry between samples and standards were monitored by measuring the count rate of a 77 As tracer added before sample dissolution. RNAA results were combined with inductively coupled plasma-mass spectrometry values from National Institute of Standards and Technology and collaborating laboratories to provide certified values of 10.81 ± 0.54 and 213.1 ± 0.73 μg/L for SRM 2668 Levels I and II, and certified values of 21.66 ± 0.73, 52.7 ± 1.1, and 78.8 ± 4.9 μg/L for SRM 955c Levels II-IV, respectively. Because of discrepancies between values obtained by different methods for SRM 955c Level I, an information value of <5 μg/L was assigned for this material. (author)

  1. The IPEM code of practice for determination of the reference air kerma rate for HDR 192Ir brachytherapy sources based on the NPL air kerma standard

    International Nuclear Information System (INIS)

    Bidmead, A M; Sander, T; Nutbrown, R F; Locks, S M; Lee, C D; Aird, E G A; Flynn, A

    2010-01-01

    This paper contains the recommendations of the high dose rate (HDR) brachytherapy working party of the UK Institute of Physics and Engineering in Medicine (IPEM). The recommendations consist of a Code of Practice (COP) for the UK for measuring the reference air kerma rate (RAKR) of HDR 192 Ir brachytherapy sources. In 2004, the National Physical Laboratory (NPL) commissioned a primary standard for the realization of RAKR of HDR 192 Ir brachytherapy sources. This has meant that it is now possible to calibrate ionization chambers directly traceable to an air kerma standard using an 192 Ir source (Sander and Nutbrown 2006 NPL Report DQL-RD 004 (Teddington: NPL) http://publications.npl.co.uk). In order to use the source specification in terms of either RAKR, .K R (ICRU 1985 ICRU Report No 38 (Washington, DC: ICRU); ICRU 1997 ICRU Report No 58 (Bethesda, MD: ICRU)), or air kerma strength, S K (Nath et al 1995 Med. Phys. 22 209-34), it has been necessary to develop algorithms that can calculate the dose at any point around brachytherapy sources within the patient tissues. The AAPM TG-43 protocol (Nath et al 1995 Med. Phys. 22 209-34) and the 2004 update TG-43U1 (Rivard et al 2004 Med. Phys. 31 633-74) have been developed more fully than any other protocol and are widely used in commercial treatment planning systems. Since the TG-43 formalism uses the quantity air kerma strength, whereas this COP uses RAKR, a unit conversion from RAKR to air kerma strength was included in the appendix to this COP. It is recommended that the measured RAKR determined with a calibrated well chamber traceable to the NPL 192 Ir primary standard is used in the treatment planning system. The measurement uncertainty in the source calibration based on the system described in this COP has been reduced considerably compared to other methods based on interpolation techniques.

  2. Reference sources for the calibration of surface contamination monitors - Beta-emitters (maximum beta energy greater than MeV) and alpha-emitters (International Standard Publication ISO 8769:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    This International Standard specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters and to beta-emitters of maximum beta energy greater than 0,15 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC Publication 325 and other documents. This International Standard specifies reference radiations for the calibration of surface contamination monitors which take the form of adequately characterized large area sources specified, without exception, in terms of activity and surface emission rate, the evaluation of these quantities being traceable to national standards

  3. Optimizing the ASC WAN: evaluating network performance tools for comparing transport protocols.

    Energy Technology Data Exchange (ETDEWEB)

    Lydick, Christopher L.

    2007-07-01

    The Advanced Simulation & Computing Wide Area Network (ASC WAN), which is a high delay-bandwidth network connection between US Department of Energy National Laboratories, is constantly being examined and evaluated for efficiency. One of the current transport-layer protocols which is used, TCP, was developed for traffic demands which are different from that on the ASC WAN. The Stream Control Transport Protocol (SCTP), on the other hand, has shown characteristics which make it more appealing to networks such as these. Most important, before considering a replacement for TCP on any network, a testing tool that performs well against certain criteria needs to be found. In order to try to find such a tool, two popular networking tools (Netperf v.2.4.3 & v.2.4.6 (OpenSS7 STREAMS), and Iperf v.2.0.6) were tested. These tools implement both TCP and SCTP and were evaluated using four metrics: (1) How effectively can the tool reach a throughput near the bandwidth? (2) How much of the CPU does the tool utilize during operation? (3) Is the tool freely and widely available? And, (4) Is the tool actively developed? Following the analysis of those tools, this paper goes further into explaining some recommendations and ideas for future work.

  4. Clinical significance of HPV DNA cotesting in Korean women with ASCUS or ASC-H.

    Science.gov (United States)

    Lee, Sanghoon; Kim, Jae Won; Hong, Jin Hwa; Song, Jae Yun; Lee, Jae Kwan; Kim, In Sun; Lee, Nak Woo

    2014-12-01

    The purpose of this study was to evaluate the clinical significance of Human papillomavirus (HPV) DNA cotesting in Korean women with abnormal Papanicolaou (Pap) smear results based on colposcopic pathology. A total of 1012 women underwent liquid-based Pap smears and hybrid capture II HPV DNA tests followed by colposcopy at the Korea University Hospital from January 2007 to May 2012. Of these women, 832 women were included in this retrospective study. The mean patient age was 45.4 ± 13.7 years (range:15-80). The distribution of Pap smear results was normal (4.7%), atypical squamous cells of uncertain significance (ASCUS) (42.1%), low-grade squamous intraepithelial lesion (26.8%), ASC-H (7.0%), and high-grade squamous intraepithelial lesion (HSIL) (19.5%). In women with ASCUS, none of the 87 HPV-negative had ≥cervical intraepithelial neoplasia (CIN2) (P age groups: ASCUS and ASC-H furnish healthcare providers with informative data. There is a lower proportion of ≥CIN2 in HPV-negative women and a higher proportion of ≥CIN2 in HPV-positive. When HPV data were further evaluated by age group, the risk of ≥CIN2 was lower in HPV-negative women, especially in women ≥30. © 2014 Wiley Periodicals, Inc.

  5. Effects of Metal Micro and Nano-Particles on hASCs: An In Vitro Model.

    Science.gov (United States)

    Palombella, Silvia; Pirrone, Cristina; Rossi, Federica; Armenia, Ilaria; Cherubino, Mario; Valdatta, Luigi; Raspanti, Mario; Bernardini, Giovanni; Gornati, Rosalba

    2017-08-03

    As the knowledge about the interferences of nanomaterials on human staminal cells are scarce and contradictory, we undertook a comparative multidisciplinary study based on the size effect of zero-valent iron, cobalt, and nickel microparticles (MPs) and nanoparticles (NPs) using human adipose stem cells (hASCs) as a model, and evaluating cytotoxicity, morphology, cellular uptake, and gene expression. Our results suggested that the medium did not influence the cell sensitivity but, surprisingly, the iron microparticles (FeMPs) resulted in being toxic. These data were supported by modifications in mRNA expression of some genes implicated in the inflammatory response. Microscopic analysis confirmed that NPs, mainly internalized by endocytosis, persist in the vesicles without any apparent cell damage. Conversely, MPs are not internalized, and the effects on hASCs have to be ascribed to the release of ions in the culture medium, or to the reduced oxygen and nutrient exchange efficiency due to the presence of MP agglomerating around the cells. Notwithstanding the results depicting a heterogeneous scene that does not allow drawing a general conclusion, this work reiterates the importance of comparative investigations on MPs, NPs, and corresponding ions, and the need to continue the thorough verification of NP and MP innocuousness to ensure unaffected stem cell physiology and differentiation.

  6. The role of colposcopy and typization of human papillomavirus in further diagnostic proceedings in patients with ASC-US cytological finding of the uterine cervix

    Directory of Open Access Journals (Sweden)

    Živadinović Radomir

    2009-01-01

    Full Text Available Background/Aim. Bethesda system of classification of cytological findings was introduced in 2001 two subcategories in the category of atypical squamous cells (ASC findings: ASC of undetermined significance (ASC-US and ASC which cannot exclude high-grade intraepithelial lesions (ASC-H. The aim of our study was to assess a possible association of these two subcategories with pathologic biopsy finding and to find out the best further diagnostic proceedings. Methods. At the Clinic of Gynecology and Obstetrics, Niš 130 patients with ASC findings were analyzed. Colposcopy was performed in all study participants. Patients with pathological colposcopic findings underwent cervical biopsy. In 10 patients with pathologic histologic and 15 with benign findings human papilloma virus (HPV typization was done using the Hybrid Capture method. Results. Patients with ASC-H finding had significantly more pathologic biopsies compared with patients with ASC-US finding (57.84: 20.72. Conclusion. Colposcopy was exhibited somewhat higher sensitivity compared to HPV typization (94.7 : 90, but lower sensitivity (79.27 : 86.6. The usage of HPV typization in the triage of patients with ASC cytologic smear induces statistically significant reduction of unnecessary percentage of cervical biopsies.

  7. Diagnostic performance of in vivo 3-T MRI for articular cartilage abnormalities in human osteoarthritic knees using histology as standard of reference

    International Nuclear Information System (INIS)

    Saadat, Ehsan; Jobke, Bjoern; Chu, Bill; Lu, Ying; Cheng, Jonathan; Li, Xiaojuan; Majumdar, Sharmila; Link, Thomas M.; Ries, Michael D.

    2008-01-01

    The purpose of this study was (1) to evaluate the sensitivity, specificity and accuracy of sagittal in vivo 3-T intermediate-weighted fast spin-echo (iwFSE) sequences in the assessment of knee cartilage pathologies using histology as the reference standard in patients undergoing total knee replacement, and (2) to correlate MR imaging findings typically associated with osteoarthritis such as bone marrow edema pattern (BMEP) and cartilage swelling with histological findings. Tibial plateaus and femoral condyles of eight knees of seven patients were resected during surgery, and sagittal histological sections were prepared for histology. Preoperative MRI findings were compared to the corresponding region in histological sections for thickness, surface integrity and signal pattern of cartilage, and histological findings in areas of BMEP and swelling were documented. The overall sensitivity, specificity and accuracy were 72%, 69% and 70% for thickness, 69%, 74% and 73% for surface and 36%, 62% and 45% for intracartilaginous signal pattern. For all cases of BMEP on MRI subchondral ingrowth of fibrovascular tissue and increased bone remodeling were observed. MRI using fat-saturated iwFSE sequences showed good performance in assessing cartilage thickness and surface lesions, while signal changes of cartilage were not suited to characterize the severity of cartilage degeneration as validated by histology. (orig.)

  8. Determination of trace elements in human blood serum and in the standard reference material ''Bovine Liver'' by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Behne, D.; Juergensen, H.

    1978-01-01

    Ag, Br, Co, Cr, Cs, Fe, Na, Rb, Sb, Se and Zn were determined in biological materials by gamma-spectrometry of long-lived radionuclides after long-time irradiation with thermal neutrons. Blood was taken from a vein in the arm of the test person via an indwelling plastic cannula. The serum was separated from other blood components by centrifugation and stored at a temperature of -20 deg C. Ampoules of high purity silica quartz were chosen as irradiation containers. The vials were cleaned by etching with 40% hydrofluoric acid. For the analysis 300 μl of serum were taken. The ampoules were irradiated for 10 days at a thermal neutron flux density of 5.10 13 n.cm -2 .sec -1 . They were then cleaned by etching for 5 min with hydrofluoric acid. The gamma-ray spectra of the irradiated samples were measured twice. From the first spectra, which were obtained 10 days after irradiation, the concentrations of Br and Na were calculated. From the gamma-peaks after a decay time of 3 months Ag, Co, Cr, Cs, Fe, Rb, Sc, Se and Zn were determined. The accuracy and precision of the procedure were tested, using the standard reference material ''Bovine Liver'' and identical serum samples. In the case of blood serum the method proved to be suitable for the determination of Br, Cs, Fe, Na, Rb, Se and Zn. By analysing samples from several subjects information about element levels in human serum was obtained. (T.G.)

  9. Renal Artery Stenosis Evaluated with 3D-Gd-Magnetic Resonance Angiography Using Transstenotic Pressure Gradient as the Standard of Reference. A Multireader Study

    International Nuclear Information System (INIS)

    Ekloef, H.; Ahlstrom, H.; Bostrom, A.; Bergqvist, D.; Andren, B.; Karacagil, S.; Nyman, R.

    2005-01-01

    Purpose: To evaluate 3D-Gd-magnetic resonance angiography (MRA) in detecting hemodynamically significant renal artery stenosis (RAS). Material and Methods: Thirty patients evaluated for atherosclerotic RAS by MRA and digital subtraction angiography (DSA) were retrospectively included. Standard of reference for hemodynamically significant RAS was a transstenotic gradient of 15 mmHg. DSA visualized 60 main renal arteries and 9 accessory arteries. Pressure gradient measurement (PGM) was available from 61 arteries. Three radiologists evaluated all examinations independently in a blinded fashion. Results: RAS was present in 26 arteries. On MRA, each reader identified 4 of 9 accessory renal arteries, a detection rate of 44%. The three readers correctly classified 22/25/22 of the 26 vessels with a significant gradient as >60% RAS and 31/25/32 of the 35 with a significant gradient as <60% RAS on MRA. Interobserver agreement was substantial. MRA image quality was adequate for RAS evaluations in all patients. ROC curves indicated that MRA is an adequate method for evaluating RAS. When screening for RAS, a 50% diameter reduction cut-off is better than 60%. RAS with 40-80% diameter reductions accounted for 65% of discrepancies. Conclusion: MRA is an adequate method for evaluating RAS limited mainly by poor detection rate for accessory renal arteries

  10. Accuracy of CT chest without oral contrast for ruling out esophageal perforation using fluoroscopic esophagography as reference standard: a retrospective study.

    Science.gov (United States)

    Awais, Muhammad; Qamar, Saqib; Rehman, Abdul; Baloch, Noor Ul-Ain; Shafqat, Gulnaz

    2018-02-26

    Esophageal perforation has a high mortality rate. Fluoroscopic esophagography (FE) is the procedure of choice for diagnosing esophageal perforation. However, FE can be difficult to perform in seriously ill patients. We retrospectively reviewed charts and scans of all patients who had undergone thoracic CT (TCT) without oral contrast and FE for suspicion of esophageal perforation at our hospital between October, 2010 and December, 2015. Scans were interpreted by a single consultant radiologist having > 5 years of relevant experience. Statistical analysis was performed using SPSS version 20. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TCT were computed using FE as reference standard. Of 122 subjects, 106 (83%) were male and their median age was 42 [inter-quartile range (IQR) 29-53] years. Esophageal perforation was evident on FE in 15 (8%) cases. Sensitivity, specificity, PPV and NPV of TCT for detecting esophageal perforation were 100, 54.6, 23.4 and 100%, respectively. When TCT was negative (n = 107), an alternative diagnosis was evident in 65 cases. Thoracic computed tomography (TCT) had 100% sensitivity and negative predictive value for excluding esophageal perforation. FE may be omitted in patients who have no evidence of mediastinal collection, pneumomediastinum or esophageal wall defect on TCT. However, in the presence of any of these features, FE is still necessary to confirm or exclude the presence of an esophageal perforation.

  11. Diagnostic performance of in vivo 3-T MRI for articular cartilage abnormalities in human osteoarthritic knees using histology as standard of reference

    Energy Technology Data Exchange (ETDEWEB)

    Saadat, Ehsan [University of California San Francisco, School of Medicine and Department of Radiology, San Francisco, CA (United States); Jobke, Bjoern; Chu, Bill; Lu, Ying; Cheng, Jonathan; Li, Xiaojuan; Majumdar, Sharmila; Link, Thomas M. [University of California San Francisco, Department of Radiology, San Francisco, CA (United States); Ries, Michael D. [University of California San Francisco, Department of Orthopaedic Surgery, San Francisco, CA (United States)

    2008-10-15

    The purpose of this study was (1) to evaluate the sensitivity, specificity and accuracy of sagittal in vivo 3-T intermediate-weighted fast spin-echo (iwFSE) sequences in the assessment of knee cartilage pathologies using histology as the reference standard in patients undergoing total knee replacement, and (2) to correlate MR imaging findings typically associated with osteoarthritis such as bone marrow edema pattern (BMEP) and cartilage swelling with histological findings. Tibial plateaus and femoral condyles of eight knees of seven patients were resected during surgery, and sagittal histological sections were prepared for histology. Preoperative MRI findings were compared to the corresponding region in histological sections for thickness, surface integrity and signal pattern of cartilage, and histological findings in areas of BMEP and swelling were documented. The overall sensitivity, specificity and accuracy were 72%, 69% and 70% for thickness, 69%, 74% and 73% for surface and 36%, 62% and 45% for intracartilaginous signal pattern. For all cases of BMEP on MRI subchondral ingrowth of fibrovascular tissue and increased bone remodeling were observed. MRI using fat-saturated iwFSE sequences showed good performance in assessing cartilage thickness and surface lesions, while signal changes of cartilage were not suited to characterize the severity of cartilage degeneration as validated by histology. (orig.)

  12. Simultaneous determination of four active components in Alisma orientale (Sam. Juz. by HPLC–DAD using a single reference standard

    Directory of Open Access Journals (Sweden)

    Yao-Wen Zhang

    2015-04-01

    Full Text Available A rapid, simple and practical high-performance liquid chromatography method coupled with diode array detector (HPLC–DAD was developed to evaluate the quality of Alisma orientale (Sam. Juz. through a simultaneous determination of four major active triterpenes using a single standard to determine the multi-components (SSDMCs. Alisol B 23-acetate was selected as the reference compound for calculating the relative response factors. All calibration curves showed good linearity (R2>0.9998 within test ranges. RSDs for intra- and inter-day of four analytes were less than 3.6% and 2.3%; the overall recovery was 92.1–110.2% (SSDMC. The proposed method was successfully applied to quantify the four components in 20 samples from different localities in China. Moreover, significant variations were demonstrated in the content of these compounds. In addition, hierarchical clustering analysis (HCA and principal components analysis (PCA were performed to differentiate and classify the samples based on the contents of Alisol C 23-acetate, Alisol A, Alisol A 24-acetate and Alisol B 23-acetate. This simple, rapid, low-cost and reliable HPLC–DAD method using SSDMC is suitable for routine quantitative analysis and quality control of A. orientale (Sam. Juz. Keywords: SSDMC, Alisma orientale (Sam. Juz, Quality control, HCA, PCA

  13. Comparison of the permeability of metoprolol and labetalol in rat, mouse, and Caco-2 cells: use as a reference standard for BCS classification.

    Science.gov (United States)

    Incecayir, Tuba; Tsume, Yasuhiro; Amidon, Gordon L

    2013-03-04

    The purpose of this study was to investigate labetalol as a potential high permeability reference standard for the application of Biopharmaceutics Classification Systems (BCS). Permeabilities of labetalol and metoprolol were investigated in animal intestinal perfusion models and Caco-2 cell monolayers. After isolating specific intestinal segments, in situ single-pass intestinal perfusions (SPIP) were performed in rats and mice. The effective permeabilities (Peff) of labetalol and metoprolol, an FDA standard for the low/high Peff class boundary, were investigated in two different segments of rat intestine (proximal jejunum and distal ileum) and in the proximal jejunum of mouse. No significant difference was found between Peff of metoprolol and labetalol in the jejunum and ileum of rat (0.33 ± 0.11 × 10(-4) vs 0.38 ± 0.06 × 10(-4) and 0.57 ± 0.17 × 10(-4) vs 0.64 ± 0.30 × 10(-4) cm/s, respectively) and in the jejunum of mouse (0.55 ± 0.05 × 10(-4) vs 0.59 ± 0.13 × 10(-4) cm/s). However, Peff of metoprolol and labetalol were 1.7 and 1.6 times higher in the jejunum of mouse, compared to the jejunum of rat, respectively. Metoprolol and labetalol showed segmental-dependent permeability through the rat intestine, with increased Peff in the distal ileum in comparison to the proximal jejunum. Most significantly, Peff of labetalol was found to be concentration-dependent. Decreasing concentrations of labetalol in the perfusate resulted in decreased Peff compared to Peff of metoprolol. The intestinal epithelial permeability of labetalol was lower than that of metoprolol in Caco-2 cells at both apical pH 6.5 and 7.5 (5.96 ± 1.96 × 10(-6) vs 9.44 ± 3.44 × 10(-6) and 15.9 ± 2.2 × 10(-6) vs 23.2 ± 7.1 × 10(-6) cm/s, respectively). Labetalol exhibited higher permeability in basolateral to apical (BL-AP) compared to AP-BL direction in Caco-2 cells at 0.1 times the highest dose strength (HDS) (46.7 ± 6.5 × 10(-6) vs 14.2 ± 1.5 × 10(-6) cm/s). The P

  14. Visualization on supercomputing platform level II ASC milestone (3537-1B) results from Sandia.

    Energy Technology Data Exchange (ETDEWEB)

    Geveci, Berk (Kitware, Inc., Clifton Park, NY); Fabian, Nathan; Marion, Patrick (Kitware, Inc., Clifton Park, NY); Moreland, Kenneth D.

    2010-09-01

    This report provides documentation for the completion of the Sandia portion of the ASC Level II Visualization on the platform milestone. This ASC Level II milestone is a joint milestone between Sandia National Laboratories and Los Alamos National Laboratories. This milestone contains functionality required for performing visualization directly on a supercomputing platform, which is necessary for peta-scale visualization. Sandia's contribution concerns in-situ visualization, running a visualization in tandem with a solver. Visualization and analysis of petascale data is limited by several factors which must be addressed as ACES delivers the Cielo platform. Two primary difficulties are: (1) Performance of interactive rendering, which is most computationally intensive portion of the visualization process. For terascale platforms, commodity clusters with graphics processors(GPUs) have been used for interactive rendering. For petascale platforms, visualization and rendering may be able to run efficiently on the supercomputer platform itself. (2) I/O bandwidth, which limits how much information can be written to disk. If we simply analyze the sparse information that is saved to disk we miss the opportunity to analyze the rich information produced every timestep by the simulation. For the first issue, we are pursuing in-situ analysis, in which simulations are coupled directly with analysis libraries at runtime. This milestone will evaluate the visualization and rendering performance of current and next generation supercomputers in contrast to GPU-based visualization clusters, and evaluate the performance of common analysis libraries coupled with the simulation that analyze and write data to disk during a running simulation. This milestone will explore, evaluate and advance the maturity level of these technologies and their applicability to problems of interest to the ASC program. Scientific simulation on parallel supercomputers is traditionally performed in four

  15. Evaluation and Validation of Organic Materials for Advanced Stirling Convertors (ASCs): Overview

    Science.gov (United States)

    Shin, Euy-Sik Eugene

    2015-01-01

    Various organic materials are used as essential parts in Stirling Convertors for their unique properties and functionalities such as bonding, potting, sealing, thread locking, insulation, and lubrication. More efficient Advanced Stirling Convertors (ASC) are being developed for future space applications especially with a long mission cycle, sometimes up to 17 years, such as deep space exploration or lunar surface power or Mars rovers, and others. Thus, performance, durability, and reliability of those organics should be critically evaluated in every possible material-process-fabrication-service environment relations based on their mission specifications. In general, thermal stability, radiation hardness, outgassing, and material compatibility of the selected organics have been systematically evaluated while their process and fabrication conditions and procedures were being optimized. Service environment-simulated long term aging tests up to 4 years were performed as a function of temperature for durability assessment of the most critical organic material systems.

  16. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    International Nuclear Information System (INIS)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun; Kim, Tae Kyoung; Khalili, Korosh; Bae, Mi Hyun; Lee, Joo Yeon; Lee, Sung-Gyu; Yu, Eun Sil

    2010-01-01

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ( pre L-S) and contrast-enhanced ( post L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ( post L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for pre L-S, post L-S and post L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of pre L-S and post L-S did not differ (P ≥ 0.054), despite a trend towards a lower accuracy with post L-S. post L-B yielded higher accuracy than pre L-S at threshold levels of 5% and 10% (P ≤ 0.002) and similar accuracy to pre L-S at the other threshold levels (P ≥ 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  17. Fluorescence optical imaging and 3T-MRI for detection of synovitis in patients with rheumatoid arthritis in comparison to a composite standard of reference.

    Science.gov (United States)

    Thuermel, Klaus; Neumann, Jan; Jungmann, Pia M; Schäffeler, Christoph; Waldt, Simone; Heinze, Alexander; Beckmann, Alexander; Hauser, Christine; Hasenau, Anna-Lena; Wildgruber, Moritz; Clotten, Sigrun; Sievert, Matti; Haller, Bernhard; Woertler, Klaus; Harasser, Norbert; Rummeny, Ernst J; Meier, Reinhard

    2017-05-01

    To address whether Indocyanine Green (ICG) enhanced fluorescence optical imaging (FOI) is more sensitive than magnetic resonance imaging (MRI) in the detection of synovitis of the wrist and finger joints in rheumatoid arthritis and to analyze the performance of FOI depending on the grade of synovitis. Twenty patients with highly active rheumatoid arthritis (mean DAS28-ESR 5.25±1.0) and thirteen healthy volunteers underwent clinical examination, FOI and contrast-enhanced 3T-MRI. Joints were rated by three independent readers semiquantitatively (grade 0-3: no, low, moderate and high grade synovitis) and compared to a semiquantitative composite standard of reference (cSOR, grade 0-3) that incorporated clinical parameters, FOI and MRI results. 2.868 evaluations in 956 joints were performed. FOI had an overall sensitivity of 57.3% and a specificity of 92.1%, whereas MRI had a sensitivity of 89.2% and a specificity of 92.6%. The sensitivity of FOI increased with the degree of synovitis to 65.0% for moderate and severe synovitis (specificity 88.1%) and 76,3% for severe synovitis (specificity 80.5%). The performance of FOI decreased with the degree of synovitis with false negative results predominantly for mild (156/343, 45.5%) and moderate (160/343, 46.6%) synovitis and false positive FOI evaluations predominantly based on weak (grade 1) signals (133/163, 81,6%). FOI has a lower sensitivity than 3T-MRI in the detection of synovitis of the hand and finger joints. The diagnostic performance of FOI decreases with the degree of synovitis and with the strength of FOI signals. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Interpreting Mobile and Handheld Air Sensor Readings in Relation to Air Quality Standards and Health Effect Reference Values: Tackling the Challenges

    Directory of Open Access Journals (Sweden)

    George M. Woodall

    2017-09-01

    Full Text Available The US Environmental Protection Agency (EPA and other federal agencies face a number of challenges in interpreting and reconciling short-duration (seconds to minutes readings from mobile and handheld air sensors with the longer duration averages (hours to days associated with the National Ambient Air Quality Standards (NAAQS for the criteria pollutants-particulate matter (PM, ozone, carbon monoxide, lead, nitrogen oxides, and sulfur oxides. Similar issues are equally relevant to the hazardous air pollutants (HAPs where chemical-specific health effect reference values are the best indicators of exposure limits; values which are often based on a lifetime of continuous exposure. A multi-agency, staff-level Air Sensors Health Group (ASHG was convened in 2013. ASHG represents a multi-institutional collaboration of Federal agencies devoted to discovery and discussion of sensor technologies, interpretation of sensor data, defining the state of sensor-related science across each institution, and provides consultation on how sensors might effectively be used to meet a wide range of research and decision support needs. ASHG focuses on several fronts: improving the understanding of what hand-held sensor technologies may be able to deliver; communicating what hand-held sensor readings can provide to a number of audiences; the challenges of how to integrate data generated by multiple entities using new and unproven technologies; and defining best practices in communicating health-related messages to various audiences. This review summarizes the challenges, successes, and promising tools of those initial ASHG efforts and Federal agency progress on crafting similar products for use with other NAAQS pollutants and the HAPs. NOTE: The opinions expressed are those of the authors and do not necessary represent the opinions of their Federal Agencies or the US Government. Mention of product names does not constitute endorsement.

  19. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Kim, Tae Kyoung; Khalili, Korosh [University of Toronto, Department of Medical Imaging, University Health Network, Toronto, ON (Canada); Bae, Mi Hyun; Lee, Joo Yeon [University of Ulsan College of Medicine, Seoul (Korea); Lee, Sung-Gyu [University of Ulsan College of Medicine, Asan Medical Center, Division of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, Seoul (Korea); Yu, Eun Sil [University of Ulsan College of Medicine, Asan Medical Center, Department of Diagnostic Pathology, Seoul (Korea)

    2010-02-15

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ({sub pre} L-S) and contrast-enhanced ({sub post} L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ({sub post} L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for{sub pre} L-S,{sub post} L-S and{sub post} L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of{sub pre} L-S and{sub post} L-S did not differ (P {>=} 0.054), despite a trend towards a lower accuracy with{sub post} L-S.{sub post} L-B yielded higher accuracy than{sub pre} L-S at threshold levels of 5% and 10% (P {<=} 0.002) and similar accuracy to{sub pre} L-S at the other threshold levels (P {>=} 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  20. STL pocket reference

    CERN Document Server

    Lischner, Ray

    2003-01-01

    The STL Pocket Reference describes the functions, classes, and templates in that part of the C++ standard library often referred to as the Standard Template Library (STL). The STL encompasses containers, iterators, algorithms, and function objects, which collectively represent one of the most important and widely used subsets of standard library functionality. The C++ standard library, even the subset known as the STL, is vast. It's next to impossible to work with the STL without some sort of reference at your side to remind you of template parameters, function invocations, return types--ind

  1. Genetic and physical analysis of a YAC contig spanning the fungal disease resistance locus Asc of tomato (Lycopersicon esculentum)

    NARCIS (Netherlands)

    Mesbah, L.A.; Kneppers, T.J.A.; Takken, F.L.W.; Laurent, P.; Hille, J.; Nijkamp, H.J.J.

    1998-01-01

    The Alternaria stem canker disease of tomato is caused by the necrotrophic fungal pathogen Alternaria alternata f. sp. lycopersici (AAL). The fungus produces AAL toxins that kill the plant tissue. Resistance to the fungus segregates as a single locus, called Asc, and has been genetically mapped on

  2. Genetic and physical analysis of a YAC contig spannig the fungal disease resistance locus Asc of tomato (Lycopersicon esculentum)

    NARCIS (Netherlands)

    Mesbah, L.A.; Kneppers, T.J.A.; Takken, F.L.W.; Laurent, P.J.F.; Hille, J.; Nijkamp, H.J.J.

    1999-01-01

    The Alternaria in stem canker disease of tomato is caused by the necrotrophic fungal pathogen Alternaria alternata f. sp. lycopersici (AAL). The fungus produces AAL toxins that kill the plant tissue. Resistance to the fungus segregates as a single locus, called Asc, and has been genetically mapped

  3. Characterization of a novel variant of amino acid transport system asc in erythrocytes from Przewalski's horse (Equus przewalskii).

    Science.gov (United States)

    Fincham, D A; Ellory, J C; Young, J D

    1992-08-01

    In thoroughbred horses, red blood cell amino acid transport activity is Na(+)-independent and controlled by three codominant genetic alleles (h, l, s), coding for high-affinity system asc1 (L-alanine apparent Km for influx at 37 degrees C congruent to 0.35 mM), low-affinity system asc2 (L-alanine Km congruent to 14 mM), and transport deficiency, respectively. The present study investigated amino acid transport mechanisms in red cells from four wild species: Przewalski's horse (Equus przewalskii), Hartmann's zebra (Zebra hartmannae), Grevy's zebra (Zebra grevyi), and onager (Equus hemonius). Red blood cell samples from different Przewalski's horses exhibited uniformly high rates of L-alanine uptake, mediated by a high-affinity asc1-type transport system. Mean apparent Km and Vmax values (+/- SE) for L-alanine influx at 37 degrees C in red cells from 10 individual animals were 0.373 +/- 0.068 mM and 2.27 +/- 0.11 mmol (L cells.h), respectively. As in thoroughbreds, the Przewalski's horse transporter interacted with dibasic as well as neutral amino acids. However, the Przewalski asc1 isoform transported L-lysine with a substantially (6.4-fold) higher apparent affinity than its thoroughbred counterpart (Km for influx 1.4 mM at 37 degrees C) and was also less prone to trans-stimulation effects. The novel high apparent affinity of the Przewalski's horse transporter for L-lysine provides additional key evidence of functional and possible structural similarities between asc and the classical Na(+)-dependent system ASC and between these systems and the Na(+)-independent dibasic amino acid transport system y+. Unlike Przewalski's horse, zebra red cells were polymorphic with respect to L-alanine transport activity, showing high-affinity or low-affinity saturable mechanisms of L-alanine uptake. Onager red cells transported this amino acid with intermediate affinity (apparent Km for influx 3.0 mM at 37 degrees C). Radiation inactivation analysis was used to estimate the target

  4. International reference reagents: antihuman globulin. An ISBT/ICSH joint working party report. International Society of Blood Transfusion. International Committee for Standardization in Haematology.

    Science.gov (United States)

    Case, J; Ford, D S; Chung, A; Collins, R; Kochman, S; Mazda, T; Overbeeke, M; Perera, R; Sakuldamrongpanich, T; Scott, M; Voak, D; Zupańska, B

    1999-01-01

    An international working party has conducted a study designed to select a suitable reference reagent for antihuman globulin, to replace those first made available in 1987. The chosen preparation contains levels of anti-IgG and anti-C3 (anti-C3c and anti-C3d) potency that are considered suitable to serve for reference when evaluating either polyspecific antihuman globulin reagents or those containing their separate monospecific components. The reference material is available in 2-ml freeze-dried aliquots from seven assigned distribution centres.

  5. The dosimetric standards for low and medium energy X-rays; Les references dosimetriques pour les rayons X de basses et moyennes energies

    Energy Technology Data Exchange (ETDEWEB)

    Ksouri, W.; Denoziere, M.; Lecerf, N.; Leroy, E.

    2009-07-01

    The Laboratoire national Henri Becquerel (LNE-LNHB) has developed national dosimetric standards for x-rays of low and medium energies. This article describes these standards which are aimed at applications of radiation protection of workers and patients in the fields of medical diagnosis and industrial x-ray radiation. Developments for contact radiotherapy are also discussed. (author)

  6. The Role of Wellbeing and Wellness: A Positive Psychological Model in Supporting Young People With ASCs

    Directory of Open Access Journals (Sweden)

    Irina Roncaglia

    2017-04-01

    Full Text Available In the last 10 years sport psychology expanded its applicability in a variety of fields which have helped to address some of the challenges related to high level performance and sport competition. When we talk about performance in its wider sense, sport psychology is able to help develop a better understanding on how strategies can be adopted in improving general human performance levels. This includes increasing the knowledge of key concepts such as motivation, self-confidence and resilience. Furthermore performance in its wider sense helps in the understanding of the impact of stress and arousal and how these can affect both positively and negatively performance levels including appreciating individual differences as well as dynamics between groups of individuals. In this paper performance rather than solely be related to the field of competitive or professional sport has been discussed in people with ASCs and aims to explore how by adopting a positive psychological model in the formulation of individual assessments and subsequent interventions have led to improvement in individual skills, participation, engagement and ultimately quality of life. Positive psychological principles, such as the role of wellbeing and wellness, the PERMA Model has increased our understanding of human potentials, performance and wellbeing. The aim of this paper is to present and reflect on the applicability and benefits of adopting sport psychology models, the PERMA model and positive psychological principles in special education and care settings with the presentation and discussion of their theoretical and some practical implementation in two case studies.

  7. Tipo de respuesta según el genotipado del virus del papiloma humano según cobas 4800 en las lesiones asc-us HPV positivas

    OpenAIRE

    Kanjou Augé, Nadwa

    2016-01-01

    Objetivos: Evaluar el riesgo de patología subyacente en las pacientes ASC-US HPV positivas de nuestra área de influencia analizadas por el método COBAS 4800. Se estudió el riesgo de CIN2+ en el momento del diagnóstico de las mujeres ASC-US HPV positivas según el genotipo del virus del papiloma: HPV16, HPV18 ( ambos incluyendo coinfecciones) u otros HPV de alto riesgo (HR-HPV). El objetivo es detectar aquellas mujeres con citologías ASC-US HPV positivo con un mayor riesgo de progresión y por l...

  8. Comparison of Centers for Disease Control and Prevention and World Health Organization references/standards for height in contemporary Australian children: analyses of the Raine Study and Australian National Children's Nutrition and Physical Activity cohorts.

    Science.gov (United States)

    Hughes, Ian; Harris, Mark; Cotterill, Andrew; Garnett, Sarah; Bannink, Ellen; Pennell, Craig; Sly, Peter; Leong, Gary M; Cowell, Chris; Ambler, Geoff; Werther, George; Hofman, Paul; Cutfield, Wayne; Choong, Catherine S

    2014-11-01

    (i) To compare the Centers for Disease Control and Prevention (CDC) reference and World Health Organization (WHO) standard/reference for height, particularly with respect to short stature and eligibility for growth hormone (GH) treatment by applying them to contemporary Australian children; (ii) To examine the implications for identifying short stature and eligibility for GH treatment. Children from the longitudinal Raine Study were serially measured for height from 1991 to 2005 (2-15-year-old girls (660) and boys (702) from Western Australia). In the cross-sectional Australian National Children's Nutrition and Physical Activity survey (2-16-year-old boys (2415) and girls (2379) from all states), height was measured in 2007. Heights were converted to standard deviation scores (SDSs) based on CDC and WHO. Means and standard deviations of height-SDS varied between CDC and WHO definitions and with age and gender within each definition. However, both identified similar frequencies of short stature (standard/reference for height. © 2014 The Authors. Journal of Paediatrics and Child Health © 2014 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  9. Is PCR the Next Reference Standard for the Diagnosis of Schistosoma in Stool? A Comparison with Microscopy in Senegal and Kenya.

    NARCIS (Netherlands)

    Meurs, L.; Brienen, E.; Mbow, M.; Ochola, E.A,; Mboup, S.; Karanja, D.M.; Secor, W.E.; Polman, K.; Lieshout, L.

    2015-01-01

    Background The current reference test for the detection of S. mansoni in endemic areas is stool microscopy based on one or more Kato-Katz stool smears. However, stool microscopy has several shortcomings that greatly affect the efficacy of current schistosomiasis control programs. A highly specific

  10. Hg0 and HgCl2 Reference Gas Standards: NIST Traceability and Comparability (And EPA ALT Methods for Hg and HCl )

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the tru...

  11. Development of Automated Procedures to Generate Reference Building Models for ASHRAE Standard 90.1 and India’s Building Energy Code and Implementation in OpenStudio

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Andrew [National Renewable Energy Lab. (NREL), Golden, CO (United States); Haves, Philip [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Jegi, Subhash [International Institute of Information Technology, Hyderabad (India); Garg, Vishal [International Institute of Information Technology, Hyderabad (India); Ravache, Baptiste [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-09-14

    This paper describes a software system for automatically generating a reference (baseline) building energy model from the proposed (as-designed) building energy model. This system is built using the OpenStudio Software Development Kit (SDK) and is designed to operate on building energy models in the OpenStudio file format.

  12. Estabilidade de ácido ascórbico em sucos de frutas frescos sob diferentes formas de armazenamento

    OpenAIRE

    Cunha, Kelly Damasceno; Silva, Priscila Ribeiro da; Costa, Ana Lígia Faria e Silva da Fonseca; Teodoro, Anderson Junger; Koblitz, Maria Gabriela Bello

    2014-01-01

    O ácido ascórbico é uma vitamina hidrossolúvel de importância nutricional há muito estabelecida, por sua atuação como cofator em diversos processos fisiológicos e como antioxidante. O ser humano depende da ingestão diária desse micronutriente, cujas principais fontes são as frutas e hortaliças. Por ser um nutriente menos estável, o ácido ascórbico sofre perdas no processamento e no armazenamento, influenciadas por diversos fatores, como pH, temperatura, presença de íons, etc. A literatura apr...

  13. Differential regulation of caspase-1 activation, pyroptosis, and autophagy via Ipaf and ASC in Shigella-infected macrophages.

    Directory of Open Access Journals (Sweden)

    Toshihiko Suzuki

    2007-08-01

    Full Text Available Shigella infection, the cause of bacillary dysentery, induces caspase-1 activation and cell death in macrophages, but the precise mechanisms of this activation remain poorly understood. We demonstrate here that caspase-1 activation and IL-1beta processing induced by Shigella are mediated through Ipaf, a cytosolic pattern-recognition receptor of the nucleotide-binding oligomerization domain (NOD-like receptor (NLR family, and the adaptor protein apoptosis-associated speck-like protein containing a C-terminal caspase recruitment domain (ASC. We also show that Ipaf was critical for pyroptosis, a specialized form of caspase-1-dependent cell death induced in macrophages by bacterial infection, whereas ASC was dispensable. Unlike that observed in Salmonella and Legionella, caspase-1 activation induced by Shigella infection was independent of flagellin. Notably, infection of macrophages with Shigella induced autophagy, which was dramatically increased by the absence of caspase-1 or Ipaf, but not ASC. Autophagy induced by Shigella required an intact bacterial type III secretion system but not VirG protein, a bacterial factor required for autophagy in epithelial-infected cells. Treatment of macrophages with 3-methyladenine, an inhibitor of autophagy, enhanced pyroptosis induced by Shigella infection, suggesting that autophagy protects infected macrophages from pyroptosis. Thus, Ipaf plays a critical role in caspase-1 activation induced by Shigella independently of flagellin. Furthermore, the absence of Ipaf or caspase-1, but not ASC, regulates pyroptosis and the induction of autophagy in Shigella-infected macrophages, providing a novel function for NLR proteins in bacterial-host interactions.

  14. Budget-impact model for colonoscopy cost calculation and comparison between 2 litre PEG+ASC and sodium picosulphate with magnesium citrate or sodium phosphate oral bowel cleansing agents.

    Science.gov (United States)

    Gruss, H-J; Cockett, A; Leicester, R J

    2012-01-01

    With the availability of several bowel cleansing agents, physicians and hospitals performing colonoscopies will often base their choice of cleansing agent purely on acquisition cost. Therefore, an easy to use budget impact model has been developed and established as a tool to compare total colon preparation costs between different established bowel cleansing agents. The model was programmed in Excel and designed as a questionnaire evaluating information on treatment costs for a range of established bowel cleansing products. The sum of costs is based on National Health Service reference costs for bowel cleansing products. Estimations are made for savings achievable when using a 2-litre polyethylene glycol with ascorbate components solution (PEG+ASC) in place of other bowel cleansing solutions. Test data were entered into the model to confirm validity and sensitivity. The model was then applied to a set of audit cost data from a major hospital colonoscopy unit in the UK. Descriptive analysis of the test data showed that the main cost drivers in the colonoscopy process are the procedure costs and costs for bed days rather than drug acquisition costs, irrespective of the cleansing agent. Audit data from a colonoscopy unit in the UK confirmed the finding with a saving of £107,000 per year in favour of PEG+ASC when compared to sodium picosulphate with magnesium citrate solution (NaPic+MgCit). For every patient group the model calculated overall cost savings. This was irrespective of the higher drug expenditure associated with the use of PEG+ASC for bowel preparation. Savings were mainly realized through reduced costs for repeat colonoscopy procedures and associated costs, such as inpatient length of stay. The budget impact model demonstrated that the primary cost driver was the procedure cost for colonoscopy. Savings can be realized through the use of PEG+ASC despite higher drug acquisition costs relative to the comparator products. From a global hospital funding

  15. 45 CFR 162.1302 - Standards for referral certification and authorization transaction.

    Science.gov (United States)

    2010-10-01

    ... Standards for Electronic Data Interchange Technical Report Type 3, April 2008, ASC X12N/005010X217E1... authorization. The NCPDP Telecommunication Standard Implementation Guide, Version 5, Release 1 (Version 5.1... (Version 1.1), January 2000, supporting Telecommunications Standard Implementation Guide, Version 5...

  16. 45 CFR 162.1202 - Standards for eligibility for a health plan transaction.

    Science.gov (United States)

    2010-10-01

    ... benefit inquiry and response. The ASC X12 Standards for Electronic Data Interchange Technical Report Type... Telecommunication Standard Implementation Guide, Version 5, Release 1 (Version 5.1), September 1999, and equivalent... supporting Telecommunications Standard Implementation Guide, Version 5, Release 1 (Version 5.1) for the NCPDP...

  17. ASCS online fault detection and isolation based on an improved MPCA

    Science.gov (United States)

    Peng, Jianxin; Liu, Haiou; Hu, Yuhui; Xi, Junqiang; Chen, Huiyan

    2014-09-01

    Multi-way principal component analysis (MPCA) has received considerable attention and been widely used in process monitoring. A traditional MPCA algorithm unfolds multiple batches of historical data into a two-dimensional matrix and cut the matrix along the time axis to form subspaces. However, low efficiency of subspaces and difficult fault isolation are the common disadvantages for the principal component model. This paper presents a new subspace construction method based on kernel density estimation function that can effectively reduce the storage amount of the subspace information. The MPCA model and the knowledge base are built based on the new subspace. Then, fault detection and isolation with the squared prediction error (SPE) statistic and the Hotelling ( T 2) statistic are also realized in process monitoring. When a fault occurs, fault isolation based on the SPE statistic is achieved by residual contribution analysis of different variables. For fault isolation of subspace based on the T 2 statistic, the relationship between the statistic indicator and state variables is constructed, and the constraint conditions are presented to check the validity of fault isolation. Then, to improve the robustness of fault isolation to unexpected disturbances, the statistic method is adopted to set the relation between single subspace and multiple subspaces to increase the corrective rate of fault isolation. Finally fault detection and isolation based on the improved MPCA is used to monitor the automatic shift control system (ASCS) to prove the correctness and effectiveness of the algorithm. The research proposes a new subspace construction method to reduce the required storage capacity and to prove the robustness of the principal component model, and sets the relationship between the state variables and fault detection indicators for fault isolation.

  18. An Alternative Optimization Model and Robust Experimental Design for the Assignment Scheduling Capability for Unmanned Aerial Vehicles (ASC-U) Simulation

    National Research Council Canada - National Science Library

    Oliver, Derek M

    2007-01-01

    .... TRAC selected ASC-U to provide insight into the programmatic decisions addressed in the U.S. Army UAV-Mix Analysis that directly affects future development and fielding of UAVs to include the Future Combat System...

  19. Growth references

    NARCIS (Netherlands)

    Buuren, S. van

    2007-01-01

    A growth reference describes the variation of an anthropometric measurement within a group of individuals. A reference is a tool for grouping and analyzing data and provides a common basis for comparing populations.1 A well known type of reference is the age-conditional growth diagram. The

  20. A study of HPV typing for the management of HPV-positive ASC-US cervical cytologic results.

    Science.gov (United States)

    Schiffman, Mark; Vaughan, Laurence M; Raine-Bennett, Tina R; Castle, Philip E; Katki, Hormuzd A; Gage, Julia C; Fetterman, Barbara; Befano, Brian; Wentzensen, Nicolas

    2015-09-01

    In US cervical screening, immediate colposcopy is recommended for women with HPV-positive ASC-US (equivocal) cytology. We evaluated whether partial typing by Onclarity™ (BD) might identify HPV-positive women with low enough CIN3+ risk to permit 1-year follow-up instead. The NCI-Kaiser Permanente Northern California Persistence and Progression cohort includes a subset of 13,890 women aged 21+ with HC2 (Qiagen)-positive ASC-US at enrollment; current median follow-up is 3.0years. Using stratified random sampling, we typed 2079 archived enrollment specimens including 329 women subsequently diagnosed with CIN3+, 563 with CIN2, and 1187 with ASC-US was 5.2%; this establishes the "benchmark" risk for colposcopic referral. Hierarchically, 3-year cumulative risks for each typing channel were 16.0% for HPV16, 7.4% for HPV18, 7.0% for HPV31, 7.1% for grouped HPV33/58, 4.3% for HPV52, 3.9% for HPV45, 2.7% for HPV51, 1.6% for HPV39/68/35, and 1.3% for HPV59/56/66. ASC-US linked to HPV16, HPV18, HPV31, or HPV33/58 warrants immediate colposcopy. Optimal management of women with HPV52 or HPV45 is uncertain. Risk of women with only HPV51, HPV39/68/35, or HPV59/56/66 might be low enough to recommend 1-year retesting permitting viral clearance. This strategy would defer colposcopy for 40% of women with HPV-positive ASC-US, half of whom would be cotest-negative at 1-year return. Approximately 10% of those with CIN3 diagnosable at enrollment would be delayed 1year instead. Cost-effectiveness analyses are needed. Published by Elsevier Inc.

  1. Digital Dilemma: Intellectual Property [and] The ERCIM Technical Reference Digital Library [and] International Information Gateway Collaboration [and] The Standards Fora for Online Education.

    Science.gov (United States)

    Gladney, Henry M.; Andreoni, Antonella; Baldacci, Maria Bruna; Biagioni, Stefania; Carlesi, Carlo; Castelli, Donatella; Pagano, Pasquale; Peters, Carol; Pisani, Serena; Dempsey, Lorcan; Gardner, Tracy; Day, Michael; van der Werf, Titia; Bacsich, Paul; Heath, Andy; Lefrere, Paul; Miller, Paul; Riley, Kevin

    1999-01-01

    Includes four articles that discuss the impact of the emerging digital information infrastructure on intellectual property; the implementation of a digital library for a European consortium of national research institutions; an international information gateway collaboration; and developing standards for the description and sharing of educational…

  2. Experience of Approbation and Target Reference Points of Introduction of the Professional Standard "Pedagogue-Psychologist (Educational psychologist" in Sverdlovsk Region

    Directory of Open Access Journals (Sweden)

    Vasyagina N.N.

    2017-11-01

    Full Text Available The experience of application of the professional standard "Pedagogue-psychologist (educational psychologist" in the Sverdlovsk region is described. A regional model for the application of the professional standard developed on the basis of the principles of unity of centralization and decentralization, interdepartmental and network interaction developed by the authors is presented. The main forms and methods of work on the application of a professional standard in the region are disclosed; the results of the Sverdlovsk region internship site are described, including mechanisms for identifying personnel shortages and development of personalized trajectories of the professional development of psychology teachers in the region. The following are highlighted as priority areas: the development of regional normative legal acts regulating the professional activity of pedagogue-psychologists, the application of the professional standard of the pedagogue-psychologist in the formation of the personnel policy in the field of education, and the modernization of the system of vocational training and additional vocational education of psychologists.

  3. Assessing factors that influence deviations between measured and calculated reference evapotranspiration

    Science.gov (United States)

    Rodny, Marek; Nolz, Reinhard

    2017-04-01

    Evapotranspiration (ET) is a fundamental component of the hydrological cycle, but challenging to be quantified. Lysimeter facilities, for example, can be installed and operated to determine ET, but they are costly and represent only point measurements. Therefore, lysimeter data are traditionally used to develop, calibrate, and validate models that allow calculating reference evapotranspiration (ET0) based on meteorological data, which can be measured more easily. The standardized form of the well-known FAO Penman-Monteith equation (ASCE-EWRI) is recommended as a standard procedure for estimating ET0 and subsequently plant water requirements. Applied and validated under different climatic conditions, the Penman-Monteith equation is generally known to deliver proper results. On the other hand, several studies documented deviations between measured and calculated ET0 depending on environmental conditions. Potential reasons are, for example, differing or varying surface characteristics of the lysimeter and the location where the weather instruments are placed. Advection of sensible heat (transport of dry and hot air from surrounding areas) might be another reason for deviating ET-values. However, elaborating causal processes is complex and requires comprehensive data of high quality and specific analysis techniques. In order to assess influencing factors, we correlated differences between measured and calculated ET0 with pre-selected meteorological parameters and related system parameters. Basic data were hourly ET0-values from a weighing lysimeter (ET0_lys) with a surface area of 2.85 m2 (reference crop: frequently irrigated grass), weather data (air and soil temperature, relative humidity, air pressure, wind velocity, and solar radiation), and soil water content in different depths. ET0_ref was calculated in hourly time steps according to the standardized procedure after ASCE-EWRI (2005). Deviations between both datasets were calculated as ET0_lys-ET0_ref and

  4. PFGE standard operating procedures for Listeria monocytogenes: harmonizing the typing of food and clinical strains in Europe.

    Science.gov (United States)

    Michelon, Damien; Félix, Benjamin; Vingadassalon, Noemie; Mariet, Jean-François; Larsson, Jonas T; Møller-Nielsen, Eva; Roussel, Sophie

    2015-03-01

    Listeria monocytogenes is a foodborne pathogen responsible for a severe disease known as listeriosis. The European Centre for Disease Prevention and Control (ECDC) coordinates a network of national public health laboratories (NPHLs) in charge of typing clinical strains. In food, it is the European Union Reference Laboratory for L. monocytogenes (EURL Lm), which manages a network of National Reference Laboratories (NRLs). A pulsed-field gel electrophoresis (PFGE) standard operating procedure (EURL SOP) has been used routinely at the EURL Lm since 2007. The EURL Lm has recommended that NRLs use the EURL SOP, whereas the Statens Serum Institut (SSI), under contract for ECDC, requested that NPHLs use Halpins' SOP (HSOP) published in 2010 for the PulseNet USA network. An update of Halpins' SOP (uHSOP) was published in 2013. To facilitate the exchange of profiles among human and food European reference laboratories, it is crucial to ensure that the PFGE profiles obtained with these different SOPs are comparable. The aim here was to compare the EURL SOP with HSOP and uHSOP. The panel comprised 114 well-characterized SSI/EURL strains. All were characterized at the EURL using both the EURL SOP and uHSOP. Seventy of the 114 strains were also characterized at the SSI using HSOP. The EURL SOP and uHSOP produced indistinguishable combined (ApaI/AscI) profiles for the 114 strains tested. The EURL SOP and HSOP produced indistinguishable combined profiles for 69 of the 70 strains tested. One strain displayed for the AscI profile an additional low-intensity band at 184 kbp with HSOP. For this strain, SSI and EUR Lm had already observed the same profile from NPHLs and NRLs. However, this deviation is minor as it accounted for about 1% of all the 114 combined profiles. This study should facilitate the exchange of reproducible PFGE profiles among human and food reference laboratories.

  5. Reference standards to assess physical fitness of children and adolescents of Brazil: an approach to the students of the Lake Itaipú region—Brazil

    Directory of Open Access Journals (Sweden)

    Edilson Hobold

    2017-11-01

    Full Text Available Background The importance of assessing body fat variables and physical fitness tests plays an important role in monitoring the level of activity and physical fitness of the general population. The objective of this study was to develop reference norms to evaluate the physical fitness aptitudes of children and adolescents based on age and sex from the lake region of Itaipú, Brazil. Methods A descriptive cross-sectional study was carried out with 5,962 students (2,938 males and 3,024 females with an age range of 6.0 and 17.9 years. Weight (kg, height (cm, and triceps (mm, and sub-scapular skinfolds (mm were measured. Body Mass Index (BMI kg/m2 was calculated. To evaluate the four physical fitness aptitude dimensions (morphological, muscular strength, flexibility, and cardio-respiratory, the following physical education tests were given to the students: sit-and-reach (cm, push-ups (rep, standing long jump (cm, and 20-m shuttle run (m. Results and Discussion Females showed greater flexibility in the sit-and-reach test and greater body fat than the males. No differences were found in BMI. Percentiles were created for the four components for the physical fitness aptitudes, BMI, and skinfolds by using the LMS method based on age and sex. The proposed reference values may be used for detecting talents and promoting health in children and adolescents.

  6. Actual survey of dose evaluation method for standardization of radiation therapy techniques. With special reference to display method of radiation doses

    International Nuclear Information System (INIS)

    Kumagai, Kozo; Yoshiura, Takao; Izumi, Takashi; Araki, Fujio; Takada, Takuo; Jingu, Kenichi.

    1994-01-01

    This report presents the results of questionnaire survey for actual conditions of radiation therapy, which was conducted with the aim of establishing the standardization of radiation therapy techniques. Questionnaires were sent to 100 facilities in Japan, and 86 of these answered, consisting of 62 university hospitals, 2 national hospitals, 14 cancer centers, 4 prefectural or municipal hospitals, and 4 other hospitals. In addition to electron beam therapy, the following typical diseases for radiation therapy were selected as standard irradiation models: cancers of the larynx, esophagus, breast, and uterine cervix, and malignant lymphomas. According to these models, questionnaire results are analyzed in terms of the following four items: (1) irradiation procedures, (2) energy used for radiotherapy, (3) the depth for calculating target absorption doses, and (4) points for displaying target absorption doses. (N.K.)

  7. Determination of blood leukocyte concentration with constant volume acquisition on a flow cytometer is comparable to individualized single platform testing with beads as internal reference standard

    DEFF Research Database (Denmark)

    Hansen, Susan; Dahl, Ronald; Hoffmann, Hans Jürgen

    2008-01-01

    at a high rate has a median of 163 microl (IQR 156-170) with TruCount tubes. Leukocyte concentrations of 26 healthy volunteers were measured twice on up to four occasions with a Bürker-Türk chamber, by single platform technology (SPT) with TruCount tubes and on the same data set using CVA. Total leukocyte...... concentrations determined by CVA correlated better with measurements in a Bürker-Türk (BT) chamber than with SPT. Concentrations determined with CVA were 1.86% higher than with BT whereas SPT data were 5.35% higher than BT (p...LeukoGating can be established using microscopy as a reference, and is comparable to BT chamber and SPT determination. Leukocyte concentrations can be measured with CVA on flow cytometers in research and clinical settings....

  8. Optimization algorithm that generates the lowest ΔEab values to a reference standard based on spectral measurements of solid inks in offset lithography

    DEFF Research Database (Denmark)

    Jensen, Søren Tapdrup

    2014-01-01

    ISO 12647-2 specifies CIELAB values for primary and secondary colors, but only tolerances for the primary solid colors. Press operators in lithography still favor density measurements for process control to assure quality and reproducibility during a production run. Since there is no direct...... relationship between density and CIELAB measurements, there is a gap between what the standard specifies and what the industry is actually doing. This research investigates the possibility of using the tolerances specified for the primary colors to achieve a better conformance of the secondary colors...

  9. Safety-evaluation report related to the final design of the Standard Nuclear Steam Supply Reference System - CESSAR System 80. Docket No. STN 50-470

    International Nuclear Information System (INIS)

    1983-03-01

    Supplement No. 1 to the Safety Evaluation Report for the application filed by Combustion Engineering, Inc. for a Final Design Approval for the Combustion Engineering Standard Safety Analysis Report (STN 50-470) has been prepared by the Office of Nuclear Reactor Regulation of the Nuclear Regulatory Commission. The purpose of this supplement is to update the Safety Evaluation by providing: (1) the evaluation of additional information submitted by the applicant since the Safety Evaluation Report was issued, (2) the evaluation of the matters the staff had under review when the Safety Evaluation Report was issued, and (3) the response to comments made by the Advisory Committee on Reactor Safeguards

  10. [Reference citation].

    Science.gov (United States)

    Brkić, Silvija

    2013-01-01

    Scientific and professional papers represent the information basis for scientific research and professional work. References important for the paper should be cited within the text, and listed at the end of the paper. This paper deals with different styles of reference citation. Special emphasis was placed on the Vancouver Style for reference citation in biomedical journals established by the International Committee of Medical Journal Editors. It includes original samples for citing various types of articles, both printed and electronic, as well as recommendations related to reference citation in accordance with the methodology and ethics of scientific research and guidelines for preparing manuscripts for publication.

  11. World Health Organization 2006 child growth standards and 2007 growth reference charts: A discussion paper by the committee on Nutrition of the European Society for Pediatric Gastroenterology, Hepatology, and Nutrition.

    Science.gov (United States)

    Turck, Dominique; Michaelsen, Kim F; Shamir, Raanan; Braegger, Christian; Campoy, Cristina; Colomb, Virginie; Decsi, Tamás; Domellöf, Magnus; Fewtrell, Mary; Kolacek, Sanja; Mihatsch, Walter; Moreno, Luis A; van Goudoever, Johannes

    2013-08-01

    Growth charts are essential for evaluating children's health including their nutrition; however, the evaluation of child growth trajectories and consequently the decision to intervene are highly dependent on the growth charts used. The aim of this discussion paper of the European Society for Paediatric Gastroenterology, Hepatology, and Nutrition Committee on Nutrition is to provide information on the background and rationale of the World Health Organization (WHO) 2006 child growth standards and WHO 2007 growth reference charts, describe their development, outline their main innovative aspects, discuss potential limitations, and make recommendations. WHO 2006 child growth standards (0-5 years) are based on prospectively collected data describing the growth of healthy infants who were breast-fed according to WHO recommendations, showing a pattern of linear growth, which is remarkably consistent between different countries and ethnic groups. WHO 2007 growth reference charts (5-19 years) are based mainly on a re-analysis of National Centre for Health Statistics data from 1977, without information on feeding. European Society for Paediatric Gastroenterology, Hepatology, and Nutrition Committee on Nutrition recommends that WHO child growth standards should be used to monitor growth in all children in the age range 0 to 2 years in Europe, whether breast- or formula-fed, and that they should be considered to be used in the age range 2 to 5 years. Implementation of the WHO child growth standards should be preceded by evaluation of the implication of their use on national healthcare policies. Health professionals should be guided on their use and interpretation and an adequate communication strategy should be available locally to ensure that parents receive clear and consistent advice. The decision on whether to implement the WHO growth references (5-19 years) should be made by national bodies because the growth pattern during the 5- to 19-year period differs between

  12. Reference Assessment

    Science.gov (United States)

    Bivens-Tatum, Wayne

    2006-01-01

    This article presents interesting articles that explore several different areas of reference assessment, including practical case studies and theoretical articles that address a range of issues such as librarian behavior, patron satisfaction, virtual reference, or evaluation design. They include: (1) "Evaluating the Quality of a Chat Service"…

  13. Safety evaluation report related to the preliminary design of the Standard Nuclear Steam Supply Reference System, RESAR SP/90 (Docket No. STN 50-601)

    International Nuclear Information System (INIS)

    1991-04-01

    On October 24, 1983, the Westinghouse Electric Corporation tendered its application for a preliminary design approval of the advanced pressurized-water reactor design for the SP/90 reactor. The Westinghouse Reference Safety Analysis Report (RESAR SP/90, Docket No. STN 50-601), describing the design of the facility, was submitted from October 24, 1983 through March 9, 1987. Staff of the US Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation, has prepared this safety evaluation report of the RESAR SP/90 on the basis of its review. Because of the stage of the design, there are open issues that have not been resolved. These issues are discussed in detail throughout this report, and a summary is provided in Section 1.6 of this report. The applicant will be required to address these and any additional such concerns that may be raised during the course of the staff's review of advanced light-water reactors in support of a final design approval application. This report shall not constitute a commitment to issue a permit or license or in any way affect the authority of the Commission, its adjudicatory boards, and other presiding officers in any proceeding under Subpart G of Title 10 of the Code of Federal Regulations, Part 2

  14. Elaboration of standards referred to human exposure to electromagnetic fields in the range of 9kHz to 300GHz in the National System of Health, Brazil

    International Nuclear Information System (INIS)

    Souza, Joao Henrique Campos de; Giacomet, Andrea Fatima; Cunha, Tarcisio; Drumond, Ivens; Sa, Fabiana O.; Mendes, Paula

    2005-01-01

    The Portaria of the Ministry of Health no. 279 (Ordinance 279), of February 22, 2005, establishes a Working Group-GT with the purpose to elaborate standards relating to human exposure to electromagnetic fields in the range of 9 kHz to 300 GHz in the Sistema Unico de Saude (National System of Health), Brazil. Since then, we have conducted several studies on the biological effects of radiation exposure in this spectral range. The GT proposes the use of the geographical instruments coupled information systems to define an alternative pattern of surveillance, based on the determination of Areas of Risks. Each source of electromagnetic radiation is associated with territorial boundaries that surround it using progressively larger distances, thus determining areas of influence whose intensity is attenuated as the distance to the source increases. This paper presents the main results obtained by the Working Group

  15. [Definition and specification requirements for PAC-systems (picture archiving and communication system). A performance index with reference to the standard "IEEE Recommended Practice for Software Requirement Specifications"].

    Science.gov (United States)

    König, H; Klose, K J

    1999-04-01

    The formulation of requirements is necessary to control the goals of a PACS project. Furthermore, in this way, the scope of functionality necessary to support radiological working processes becomes clear. Definitions of requirements and specification are formulated independently of systems according to the IEEE standard "Recommended Practice for Software Requirements Specifications". Definitions are given in the Request for Information, specifications in the Request for Proposal. Functional and non-functional requirements are distinguished. The solutions are rated with respect to scope, appropriateness and quality of implementation. A PACS checklist was created according to the methods described above. It is published on the homepage of the "Arbeitsgemeinschaft Informationstechnologie" (AGIT) within the "Deutsche Röntgengesellschaft" (DRG) (http://www.uni-marburg.de/mzr/agit). The checklist provides a discussion forum which should contribute to an agreement on accepted basic PACS functionalities.

  16. Certification of selected polynuclear aromatic hydrocarbons in standard reference material 1580, 'Organics in Shale Oil'. Final report

    Energy Technology Data Exchange (ETDEWEB)

    May, W.E.; Brown-Thomas, J.M.; Hilpert, L.R.; Wise, S.A.

    1981-01-01

    Two independent analytical methods were developed and used to certify the concentrations of five polynuclear aromatic hydrocarbons (PAH) in a shale oil sample (SRM 1580). In the sequential high-performance liquid chromatographic method, PAH are isolated from the matrix by chromatography on an aminosilane column. The individual analyte species were separated, identified, and quantified by chromatography on an octadecylsilane column with spectrofluorimetric detection. Dilution of the sample in methylene chloride was the only sample preparation step necessary prior to analysis by gas chromatography/mass spectrometry (GC/MS). The GC/MS determinations were performed using selected ion monitoring (SIM) and a standard addition technique for quantification. The polynuclear aromatic hydrocarbons of interest were separated on a 30 m SE-52 wall coated open tubular column interfaced to a quadrupole mass spectrometer through a 25 cm length of Pt/Ir tubing (0.15 mm i.d.). Excellent agreement was observed between the data obtained from these methods.

  17. MRI of the temporo-mandibular joint: which sequence is best suited to assess the cortical bone of the mandibular condyle? A cadaveric study using micro-CT as the standard of reference

    International Nuclear Information System (INIS)

    Karlo, Christoph A.; Patcas, Raphael; Signorelli, Luca; Mueller, Lukas; Kau, Thomas; Watzal, Helmut; Kellenberger, Christian J.; Ullrich, Oliver; Luder, Hans-Ulrich

    2012-01-01

    To determine the best suited sagittal MRI sequence out of a standard temporo-mandibular joint (TMJ) imaging protocol for the assessment of the cortical bone of the mandibular condyles of cadaveric specimens using micro-CT as the standard of reference. Sixteen TMJs in 8 human cadaveric heads (mean age, 81 years) were examined by MRI. Upon all sagittal sequences, two observers measured the cortical bone thickness (CBT) of the anterior, superior and posterior portions of the mandibular condyles (i.e. objective analysis), and assessed for the presence of cortical bone thinning, erosions or surface irregularities as well as subcortical bone cysts and anterior osteophytes (i.e. subjective analysis). Micro-CT of the condyles was performed to serve as the standard of reference for statistical analysis. Inter-observer agreements for objective (r = 0.83-0.99, P < 0.01) and subjective (κ = 0.67-0.88) analyses were very good. Mean CBT measurements were most accurate, and cortical bone thinning, erosions, surface irregularities and subcortical bone cysts were best depicted on the 3D fast spoiled gradient echo recalled sequence (3D FSPGR). The most reliable MRI sequence to assess the cortical bone of the mandibular condyles on sagittal imaging planes is the 3D FSPGR sequence. (orig.)

  18. MRI of the temporo-mandibular joint: which sequence is best suited to assess the cortical bone of the mandibular condyle? A cadaveric study using micro-CT as the standard of reference

    Energy Technology Data Exchange (ETDEWEB)

    Karlo, Christoph A. [University Hospital Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland); Patcas, Raphael; Signorelli, Luca; Mueller, Lukas [University of Zurich, Clinic for Orthodontics and Pediatric Dentistry, Center of Dental Medicine, Zurich (Switzerland); Kau, Thomas; Watzal, Helmut; Kellenberger, Christian J. [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland); Ullrich, Oliver [University of Zurich, Institute of Anatomy, Faculty of Medicine, Zurich (Switzerland); Luder, Hans-Ulrich [University of Zurich, Section of Orofacial Structures and Development, Center of Dental Medicine, Zurich (Switzerland)

    2012-07-15

    To determine the best suited sagittal MRI sequence out of a standard temporo-mandibular joint (TMJ) imaging protocol for the assessment of the cortical bone of the mandibular condyles of cadaveric specimens using micro-CT as the standard of reference. Sixteen TMJs in 8 human cadaveric heads (mean age, 81 years) were examined by MRI. Upon all sagittal sequences, two observers measured the cortical bone thickness (CBT) of the anterior, superior and posterior portions of the mandibular condyles (i.e. objective analysis), and assessed for the presence of cortical bone thinning, erosions or surface irregularities as well as subcortical bone cysts and anterior osteophytes (i.e. subjective analysis). Micro-CT of the condyles was performed to serve as the standard of reference for statistical analysis. Inter-observer agreements for objective (r = 0.83-0.99, P < 0.01) and subjective ({kappa} = 0.67-0.88) analyses were very good. Mean CBT measurements were most accurate, and cortical bone thinning, erosions, surface irregularities and subcortical bone cysts were best depicted on the 3D fast spoiled gradient echo recalled sequence (3D FSPGR). The most reliable MRI sequence to assess the cortical bone of the mandibular condyles on sagittal imaging planes is the 3D FSPGR sequence. (orig.)

  19. MRI of the temporo-mandibular joint: which sequence is best suited to assess the cortical bone of the mandibular condyle? A cadaveric study using micro-CT as the standard of reference.

    Science.gov (United States)

    Karlo, Christoph A; Patcas, Raphael; Kau, Thomas; Watzal, Helmut; Signorelli, Luca; Müller, Lukas; Ullrich, Oliver; Luder, Hans-Ulrich; Kellenberger, Christian J

    2012-07-01

    To determine the best suited sagittal MRI sequence out of a standard temporo-mandibular joint (TMJ) imaging protocol for the assessment of the cortical bone of the mandibular condyles of cadaveric specimens using micro-CT as the standard of reference. Sixteen TMJs in 8 human cadaveric heads (mean age, 81 years) were examined by MRI. Upon all sagittal sequences, two observers measured the cortical bone thickness (CBT) of the anterior, superior and posterior portions of the mandibular condyles (i.e. objective analysis), and assessed for the presence of cortical bone thinning, erosions or surface irregularities as well as subcortical bone cysts and anterior osteophytes (i.e. subjective analysis). Micro-CT of the condyles was performed to serve as the standard of reference for statistical analysis. Inter-observer agreements for objective (r = 0.83-0.99, P < 0.01) and subjective (κ = 0.67-0.88) analyses were very good. Mean CBT measurements were most accurate, and cortical bone thinning, erosions, surface irregularities and subcortical bone cysts were best depicted on the 3D fast spoiled gradient echo recalled sequence (3D FSPGR). The most reliable MRI sequence to assess the cortical bone of the mandibular condyles on sagittal imaging planes is the 3D FSPGR sequence. MRI may be used to assess the cortical bone of the TMJ. • Depiction of cortical bone is best on 3D FSPGR sequences. • MRI can assess treatment response in patients with TMJ abnormalities.

  20. Androgen receptor (AR) degradation enhancer ASC-J9® in an FDA-approved formulated solution suppresses castration resistant prostate cancer cell growth.

    Science.gov (United States)

    Cheng, Max A; Chou, Fu-Ju; Wang, Keliang; Yang, Rachel; Ding, Jie; Zhang, Qiaoxia; Li, Gonghui; Yeh, Shuyuan; Xu, Defeng; Chang, Chawnshang

    2018-03-28

    ASC-J9 ® is a recently-developed androgen receptor (AR)-degradation enhancer that effectively suppresses castration resistant prostate cancer (PCa) cell proliferation and invasion. The optimal half maximum inhibitory concentrations (IC 50 ) of ASC-J9 ® at various PCa cell confluences (20%, 50%, and 100%) were assessed via both short-term MTT growth assays and long-term clonogenic proliferation assays. Our results indicate that the IC 50 values for ASC-J9 ® increased with increasing cell confluency. The IC 50 values were significantly decreased in PCa AR-positive cells compared to PCa AR-negative cells or in normal prostate cells. This suggests that ASC-J9 ® may function mainly via targeting the AR-positive PCa cells with limited unwanted side-effects to suppress the surrounding normal prostate cells. Mechanism dissection indicated that ASC-J9 ® might function via altering the apoptosis signals to suppress the PCa AR-negative PC-3 cells. Preclinical studies using multiple in vitro PCa cell lines and an in vivo mouse model with xenografted castration-resistant PCa CWR22Rv1 cells demonstrated that ASC-J9 ® has similar AR degradation effects when dissolved in FDA-approved solvents, including DMSO, PEG-400:Tween-80 (95:5), DMA:Labrasol:Tween-80 (10:45:45), and DMA:Labrasol:Tween-20 (10:45:45). Together, results from preclinical studies suggest a potential new therapy with AR-degradation enhancer ASC-J9 ® may potentially be ready to be used in human clinical trials in order to better suppress PCa at later castration resistant stages. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Human adipose stem cell and ASC-derived cardiac progenitor cellular therapy improves outcomes in a murine model of myocardial infarction

    Directory of Open Access Journals (Sweden)

    Davy PMC

    2015-10-01

    Full Text Available Philip MC Davy,1 Kevin D Lye,2,3 Juanita Mathews,1 Jesse B Owens,1 Alice Y Chow,1 Livingston Wong,2 Stefan Moisyadi,1 Richard C Allsopp1 1Institute for Biogenesis Research, 2John A. Burns School of Medicine, University of Hawaii at Mānoa, 3Tissue Genesis, Inc., Honolulu, HI, USA Background: Adipose tissue is an abundant and potent source of adult stem cells for transplant therapy. In this study, we present our findings on the potential application of adipose-derived stem cells (ASCs as well as induced cardiac-like progenitors (iCPs derived from ASCs for the treatment of myocardial infarction. Methods and results: Human bone marrow (BM-derived stem cells, ASCs, and iCPs generated from ASCs using three defined cardiac lineage transcription factors were assessed in an immune-compromised mouse myocardial infarction model. Analysis of iCP prior to transplant confirmed changes in gene and protein expression consistent with a cardiac phenotype. Endpoint analysis was performed 1 month posttransplant. Significantly increased endpoint fractional shortening, as well as reduction in the infarct area at risk, was observed in recipients of iCPs as compared to the other recipient cohorts. Both recipients of iCPs and ASCs presented higher myocardial capillary densities than either recipients of BM-derived stem cells or the control cohort. Furthermore, mice receiving iCPs had a significantly higher cardiac retention of transplanted cells than all other groups. Conclusion: Overall, iCPs generated from ASCs outperform BM-derived stem cells and ASCs in facilitating recovery from induced myocardial infarction in mice. Keywords: adipose stem cells, myocardial infarction, cellular reprogramming, cellular therapy, piggyBac, induced cardiac-like progenitors

  2. Standardization of clinical enzyme analysis using frozen human serum pools with values assigned by the International Federation of Clinical Chemistry and Laboratory Medicine reference measurement procedures.

    Science.gov (United States)

    Tong, Qing; Chen, Baorong; Zhang, Rui; Zuo, Chang

    Variation in clinical enzyme analysis, particularly across different measuring systems and laboratories, represents a critical but long-lasting problem in diagnosis. Calibrators with traceability and commutability are imminently needed to harmonize analysis in laboratory medicine. Fresh frozen human serum pools were assigned values for alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma-glutamyltransferase (GGT), creatine kinase (CK) and lactate dehydrogenase (LDH) by six laboratories with established International Federation of Clinical Chemistry and Laboratory Medicine reference measurement procedures. These serum pools were then used across 76 laboratories as a calibrator in the analysis of five enzymes. Bias and imprecision in the measurement of the five enzymes tested were significantly reduced by using the value-assigned serum in analytical systems with open and single-point calibration. The median (interquartile range) of the relative biases of ALT, AST, GGT, CK and LDH were 2.0% (0.6-3.4%), 0.8% (-0.8-2.3%), 1.0% (-0.5-2.0%), 0.2% (-0.3-1.0%) and 0.2% (-0.9-1.1%), respectively. Before calibration, the interlaboratory coefficients of variation (CVs) in the analysis of patient serum samples were 8.0-8.2%, 7.3-8.5%, 8.1-8.7%, 5.1-5.9% and 5.8-6.4% for ALT, AST, GGT, CK and LDH, respectively; after calibration, the CVs decreased to 2.7-3.3%, 3.0-3.6%, 1.6-2.1%, 1.8-1.9% and 3.3-3.5%, respectively. The results suggest that the use of fresh frozen serum pools significantly improved the comparability of test results in analytical systems with open and single-point calibration.

  3. Determination of trace sulfur in biodiesel and diesel standard reference materials by isotope dilution sector field inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Amais, Renata S. [Group of Applied Instrumental Analysis, Department of Chemistry, Federal University of São Carlos, São Carlos, SP (Brazil); Long, Stephen E. [Chemical Sciences Division, National Institute of Standards and Technology, Charleston, SC (United States); Nóbrega, Joaquim A. [Group of Applied Instrumental Analysis, Department of Chemistry, Federal University of São Carlos, São Carlos, SP (Brazil); Christopher, Steven J., E-mail: steven.christopher@nist.gov [Chemical Sciences Division, National Institute of Standards and Technology, Charleston, SC (United States)

    2014-01-02

    Graphical abstract: -- Highlights: •Sulfur mass fractions are measured below 10 mg kg{sup −1} in diesel fuel materials. •SF-ICP-MS resolves molecular interferences, including oxygen and sulfur hydrides. •A detection limit of 0.7 mg kg{sup −1} (in the fuel sample) was obtained. -- Abstract: A method is described for quantification of sulfur at low concentrations on the order of mg kg{sup −1} in biodiesel and diesel fuels using isotope dilution and sector field inductively coupled plasma mass spectrometry (ID-SF-ICP-MS). Closed vessel microwave-assisted digestion was employed using a diluted nitric acid and hydrogen peroxide decomposition medium to reduce sample dilution volumes. Medium resolution mode was employed to eliminate isobaric interferences at {sup 32}S and {sup 34}S related to polyatomic phosphorus and oxygen species, and sulfur hydride species. The method outlined yielded respective limits of detection (LOD) and limits of quantification (LOQ) of 0.7 mg kg{sup −1} S and 2.5 mg kg{sup −1} S (in the sample). The LOD was constrained by instrument background counts at {sup 32}S but was sufficient to facilitate value assignment of total S mass fraction in NIST SRM 2723b Sulfur in Diesel Fuel Oil at 9.06 ± 0.13 mg kg{sup −1}. No statistically significant difference at a 95% confidence level was observed between the measured and certified values for certified reference materials NIST SRM 2773 B100 Biodiesel (Animal-Based), CENAM DRM 272b and NIST SRM 2723a Sulfur in Diesel Fuel Oil, validating method accuracy.

  4. Estimating prevalence and diagnostic test characteristics of bovine cysticercosis in Belgium in the absence of a 'gold standard' reference test using a Bayesian approach.

    Science.gov (United States)

    Jansen, Famke; Dorny, Pierre; Gabriël, Sarah; Eichenberger, Ramon Marc; Berkvens, Dirk

    2018-04-30

    A Bayesian model was developed to estimate values for the prevalence and diagnostic test characteristics of bovine cysticercosis (Taenia saginata) by combining results of four imperfect tests. Samples of 612 bovine carcases that were found negative for cysticercosis during routine meat inspection collected at three Belgian slaughterhouses, underwent enhanced meat inspection (additional incisions in the heart), dissection of the predilection sites, B158/B60 Ag-ELISA and ES Ab-ELISA. This Bayesian approach allows for the combination of prior expert opinion with experimental data to estimate the true prevalence of bovine cysticercosis in the absence of a gold standard test. A first model (based on a multinomial distribution and including all possible interactions between the individual tests) required estimation of 31 parameters, while only allowing for 15 parameters to be estimated. Including prior expert information about specificity and sensitivity resulted in an optimal model with a reduction of the number of parameters to be estimated to 8. The estimated bovine cysticercosis prevalence was 33.9% (95% credibility interval: 27.7-44.4%), while apparent prevalence based on meat inspection is only 0.23%. The test performances were estimated as follows (sensitivity (Se) - specificity (Sp)): enhanced meat inspection (Se 2.87% - Sp 100%), dissection of predilection sites (Se 69.8% - Sp 100%), Ag-ELISA (Se 26.9% - Sp 99.4%), Ab-ELISA (Se 13.8% - Sp 92.9%). Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Comparability of reference values

    International Nuclear Information System (INIS)

    Rossbach, M.; Stoeppler, M.

    1993-01-01

    Harmonization of certified values in Reference Materials (RMs) can be carried out by applying nuclear analytical techniques to RMs of various matrix types and concentration levels. Although RMs generally should not be used as primary standards the cross evaluation of concentrations in RMs leads to better compatibility of reference values and thus to a greater agreement between analytical results from different laboratories using these RMs for instrument calibration and quality assurance. (orig.)

  6. Low-frequency, low-magnitude vibrations (LFLM enhances chondrogenic differentiation potential of human adipose derived mesenchymal stromal stem cells (hASCs

    Directory of Open Access Journals (Sweden)

    Krzysztof Marycz

    2016-02-01

    Full Text Available The aim of this study was to evaluate if low-frequency, low-magnitude vibrations (LFLM could enhance chondrogenic differentiation potential of human adipose derived mesenchymal stem cells (hASCs with simultaneous inhibition of their adipogenic properties for biomedical purposes. We developed a prototype device that induces low-magnitude (0.3 g low-frequency vibrations with the following frequencies: 25, 35 and 45 Hz. Afterwards, we used human adipose derived mesenchymal stem cell (hASCS, to investigate their cellular response to the mechanical signals. We have also evaluated hASCs morphological and proliferative activity changes in response to each frequency. Induction of chondrogenesis in hASCs, under the influence of a 35 Hz signal leads to most effective and stable cartilaginous tissue formation through highest secretion of Bone Morphogenetic Protein 2 (BMP-2, and Collagen type II, with low concentration of Collagen type I. These results correlated well with appropriate gene expression level. Simultaneously, we observed significant up-regulation of α3, α4, β1 and β3 integrins in chondroblast progenitor cells treated with 35 Hz vibrations, as well as Sox-9. Interestingly, we noticed that application of 35 Hz frequencies significantly inhibited adipogenesis of hASCs. The obtained results suggest that application of LFLM vibrations together with stem cell therapy might be a promising tool in cartilage regeneration.

  7. Comparison study for the CCME reference method for determination of PHC in soil by using internal and external standard methods and by using silica gel column cleanup and in-situ silica gel cleanup methods

    International Nuclear Information System (INIS)

    Wang, Z.; Fingas, M.; Sigouin, L.; Yang, C.; Hollebone, B.

    2003-01-01

    The assessment, cleanup, and remediation of hydrocarbon contaminated sites is covered in the Reference Method for Canada-Wide Standard for Petroleum Hydrocarbons-Tier 1 Method. It replaces several analytical methods used in the past by some laboratories and jurisdictions in Canada. The authors conducted two comparative evaluations to validate the Tier 1 Analytical Method. The first compared the Internal and External Standard Methods, and the second compared the Silica Gel Column Cleanup Method with the In-situ Silica Gel Cleanup Method. The Canadian Council of Ministers of the Environment (CCME) Tier 1 Method recommends and requires the External Standard Method to determine petroleum hydrocarbons (PHC) in soil samples. The Internal Method is widely used to quantify various organic and inorganic pollutants in environmental samples. The Tier 1 Method offers two options for the same extract cleanup. They are: Option A - In-situ Silica Gel Cleanup, and Option B - Silica Gel Column Cleanup. Linearity, precision, and PHC quantification results were the parameters considered for diesel and motor oil solutions, for diesel spiked soil samples, and for motor oil spiked soil samples. It was concluded that both the External and Internal Standard Methods for gas chromatograph (GC) determination of PHC in soil possess their own advantages. The PHC results obtained using the In-Situ Silica Gel Cleanup Method were lower than those obtained with the Silica Gel Column Cleanup Methods. The more efficient and effective sample cleanup method proved to be the Silica Gel Column Method. 13 refs., 7 tabs., 7 figs

  8. Mejora de la calidad de las medidas de ozono mediante un fotómetro UV de referencia Improvement of the quality of the ozone measurements by means of a standard reference photometer

    Directory of Open Access Journals (Sweden)

    R. Fernández Patier

    2001-11-01

    Full Text Available La Directiva 92/72/CE hace referencia al método de análisis descrito en la UNE 77-221:2000 y a que los analizadores de ozono se deben calibrar con un fotómetro UV de referencia o con un patrón transferido.De la necesidad de desarrollar un procedimiento que asegure la calidad y la trazabilidad de las mediciones en España, el Área de Contaminación Atmosférica ha decidido implantar un fotómetro UV de referencia NIST como patrón de ozono.Teniendo en cuenta los procedimientos empleados por EPA y NIST, se ha desarrollado un procedimiento de verificación consistente en la realización de 6 comparaciones del Patrón Transferido frente al Fotómetro UV de Referencia NIST, en días diferentes, analizándose, como mínimo, 5 concentraciones de ozono diferentes. Cada comparación se inicia y se finaliza siempre con una concentración de 0 ppb de O3. De cada comparación se obtiene una regresión lineal.Una vez realizadas las 6 comparaciones se obtiene la Recta de calibración y se calcula la incertidumbre asociada al patrón transferido.Se ha realizado la verificación de 17 patrones transferidos de los que 11 son fotómetros UV, 2 son generadores de ozono y 4 son generadores de ozono de bancos de dilución.De los resultados se concluye que las incertidumbres de los generadores de ozono, en general, son mayores que las de los fotómetros UV, recomendándose estos últimos como patrones transferidos.Destacar que mediante la utilización de los patrones transferidos para la calibración de analizadores de ozono se garantiza tanto la calidad como la trazabilidad de los datos generados.The Directive 92/72/CE makes reference to the analysis method described in the UNE 77-221:2000 and to the fact that the ozone analyzers shall be calibrated with a UV reference photometer or with a transfer standard.From the need of developing a procedure that assure the quality and the trazability of the measurements in Spain, the Atmospheric Pollution Area has decided

  9. Hepatic fat quantification: a prospective comparison of magnetic resonance spectroscopy and analysis methods for chemical-shift gradient echo magnetic resonance imaging with histologic assessment as the reference standard.

    Science.gov (United States)

    Kang, Bo-Kyeong; Yu, Eun Sil; Lee, Seung Soo; Lee, Youngjoo; Kim, Namkug; Sirlin, Claude B; Cho, Eun Yoon; Yeom, Suk Keu; Byun, Jae Ho; Park, Seong Ho; Lee, Moon-Gyu

    2012-06-01

    The aims of this study were to assess the confounding effects of hepatic iron deposition, inflammation, and fibrosis on hepatic steatosis (HS) evaluation by magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) and to assess the accuracies of MRI and MRS for HS evaluation, using histology as the reference standard. In this institutional review board-approved prospective study, 56 patients gave informed consents and underwent chemical-shift MRI and MRS of the liver on a 1.5-T magnetic resonance scanner. To estimate MRI fat fraction (FF), 4 analysis methods were used (dual-echo, triple-echo, multiecho, and multi-interference), and MRS FF was calculated with T2 correction. Degrees of HS, iron deposition, inflammation, and fibrosis were analyzed in liver resection (n = 37) and biopsy (n = 19) specimens. The confounding effects of histology on fat quantification were assessed by multiple linear regression analysis. Using the histologic degree of HS as the reference standard, the accuracies of each method in estimating HS and diagnosing an HS of 5% or greater were determined by linear regression and receiver operating characteristic analyses. Iron deposition significantly confounded estimations of FF by the dual-echo (P hepatic fat, with coexisting histologic abnormalities having no confounding effects.

  10. Performance evaluation of working standard NE2581 in comparison with reference standard NE2561 in the determination of absorbed dose to water using IAEA, HPA, NACP, AAPM, NCRP and ICRU protocols

    International Nuclear Information System (INIS)

    Dolah, M.T.; Supian Samat; Taiman Kadni

    2001-01-01

    The aim of this study was to evaluate the performance of NE 2581 in comparison with NE 2561 in the determination of the absorbed dose to water in a γ-ray beam using IAEA, HPA, NACP, AAPM, NCRP and ICRU protocols. 13 exposures of the γ-ray beams were used. This number of exposures yielded 26 chamber rate readings for NE 2581 (N=13) and for NE 2561 (N=13). From the 13 NE 2581 readings, 78 absorbed dose to water values were calculated for the IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. Similarly, from the 13 NE 2561 readings, 78 absorbed dose to water values were calculated for IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. From these 156 (=78 x 2) absorbed dose to water values, 78 percentage deviations between the NE 2581 and NE 2561 results were calculated for IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. For a single protocol, the mean μ and standard error σ+s+e of the percentage deviations (N=13) were calculated. results obtained in terms of [protocol, μ ± σ se ] were [IAEA,1.55 ± 0.12], [HPA, 0.98 ± 0.12], [NACP, 1.93 ± 0.12], [AAPM, -0.06 ± 0.12], [NCRP, 0.97 ± 0.12], [ICRU, 0.97 ± 0.12]. It can be seen that the range of percentage deviations is from -0.06 to 1.93. As the quoted IAEA acceptable limit of deviation is ± 3.0%, it was concluded that the working standard NE 2581 chamber has shown acceptable performance. In addition, the use of the AAPM protocol has enable NE 2581 to show a performance that is very similar like NE 2561. (Author)

  11. Interferência do ácido ascórbico na dosagem glicêmica - doi: 10.5102/ucs.v6i2.722

    OpenAIRE

    Aline Cardoso Barbosa; Tania Cristina Andrade

    2009-01-01

    Sabe-se que exames laboratoriais estão sujeitos a fatores interferentes. A literatura científica cita interferência do ácido ascórbico em dosagens que envolvam oxirredução, como a glicêmica. Devido a isto, buscou-se avaliar o efeito do ácido ascórbico sobre a dosagem glicêmica em dois tipos de soro controle submetidos a diferentes concentrações de ácido ascórbico, variando de 2,5 a 100 mg/dL. Utilizou-se um soro controle com valores normais de glicemia e outro com valores patológicos. Observo...

  12. Observaciones histopatologicas de juveniles penaeus vannamei sometidos a dietas artificiales con diferentes concentraciones de una sal de ácido ascórbico (vitamina c)

    OpenAIRE

    Vera Muñoz, L.

    1995-01-01

    Observaciones histopatologicas de juveniles Penaeus Vannamei sometidos a dietas artificiales con diferentes concentraciones de una sal de ácido ascórbico (vitamina C) Se realizaron análisis histológicos y comprobación mediante métodos histoquímicos de la presencia de melanina, a juveniles Penaeus vannamei sometidos a cinco dietas experimentales con diferentes concentraciones de una sal de L-Ascorbato-2-Fosfato de Mg (APM) usada como fuente de ácido ascórbico (AA).

  13. Inflammasome components ASC and AIM2 modulate the acute phase of biomaterial implant-induced foreign body responses

    Science.gov (United States)

    Christo, Susan N.; Diener, Kerrilyn R.; Manavis, Jim; Grimbaldeston, Michele A.; Bachhuka, Akash; Vasilev, Krasimir; Hayball, John D.

    2016-01-01

    Detailing the inflammatory mechanisms of biomaterial-implant induced foreign body responses (FBR) has implications for revealing targetable pathways that may reduce leukocyte activation and fibrotic encapsulation of the implant. We have adapted a model of poly(methylmethacrylate) (PMMA) bead injection to perform an assessment of the mechanistic role of the ASC-dependent inflammasome in this process. We first demonstrate that ASC−/− mice subjected to PMMA bead injections had reduced cell infiltration and altered collagen deposition, suggesting a role for the inflammasome in the FBR. We next investigated the NLRP3 and AIM2 sensors because of their known contributions in recognising damaged and apoptotic cells. We found that NLRP3 was dispensable for the fibrotic encapsulation; however AIM2 expression influenced leukocyte infiltration and controlled collagen deposition, suggesting a previously unexplored link between AIM2 and biomaterial-induced FBR. PMID:26860464

  14. Uranium reference materials

    International Nuclear Information System (INIS)

    Donivan, S.; Chessmore, R.

    1987-07-01

    The Technical Measurements Center has prepared uranium mill tailings reference materials for use by remedial action contractors and cognizant federal and state agencies. Four materials were prepared with varying concentrations of radionuclides, using three tailings materials and a river-bottom soil diluent. All materials were ground, dried, and blended thoroughly to ensure homogeneity. The analyses on which the recommended values for nuclides in the reference materials are based were performed, using independent methods, by the UNC Geotech (UNC) Chemistry Laboratory, Grand Junction, Colorado, and by C.W. Sill (Sill), Idaho National Engineering Laboratory, Idaho Falls, Idaho. Several statistical tests were performed on the analytical data to characterize the reference materials. Results of these tests reveal that the four reference materials are homogeneous and that no large systematic bias exists between the analytical methods used by Sill and those used by TMC. The average values for radionuclides of the two data sets, representing an unbiased estimate, were used as the recommended values for concentrations of nuclides in the reference materials. The recommended concentrations of radionuclides in the four reference materials are provided. Use of these reference materials will aid in providing uniform standardization among measurements made by remedial action contractors. 11 refs., 9 tabs

  15. World Health Organization 2006 Child Growth Standards and 2007 Growth Reference Charts: A Discussion Paper by the Committee on Nutrition of the European Society for Pediatric Gastroenterology, Hepatology, and Nutrition

    DEFF Research Database (Denmark)

    Turck, Dominique; Michaelsen, Kim F.; Shamir, Raanan

    2013-01-01

    Growth charts are essential for evaluating children’s health including their nutrition; however, the evaluation of child growth trajectories and consequently the decision to intervene are highly dependent on the growth charts used. The aim of this discussion paper of the European Society for Paed......Growth charts are essential for evaluating children’s health including their nutrition; however, the evaluation of child growth trajectories and consequently the decision to intervene are highly dependent on the growth charts used. The aim of this discussion paper of the European Society...... for Paediatric Gastroenterology, Hepatology, and Nutrition Committee on Nutrition is to provide information on the background and rationale of the World Health Organization (WHO) 2006 child growth standards and WHO 2007 growth reference charts, describe their development, outline their main innovative aspects...... between different countries and ethnic groups. WHO 2007 growth reference charts (5–19 years) are based mainly on a re-analysis of National Centre for Health Statistics data from 1977, without information on feeding. European Society for Paediatric Gastroenterology, Hepatology, and Nutrition Committee...

  16. Pangasius in the EU market; Prospects for the position of (ASC-certified) pangasius in the EU retail and food service sector

    NARCIS (Netherlands)

    Beukers, R.; Pijl, van der W.; Duijn, van A.P.

    2014-01-01

    The objective of this market study is to investigate the potential short- and long-term benefits for investors to invest in the production of pangasius with a trademark based on ASC certification, for the retail and food service market segments in the EU market.

  17. HTML & XHTML Pocket Reference

    CERN Document Server

    Robbins, Jennifer

    2010-01-01

    After years of using spacer GIFs, layers of nested tables, and other improvised solutions for building your web sites, getting used to the more stringent standards-compliant design can be intimidating. HTML and XHTML Pocket Reference is the perfect little book when you need answers immediately. Jennifer Niederst-Robbins, author Web Design in a Nutshell, has revised and updated the fourth edition of this pocket guide by taking the top 20% of vital reference information from her Nutshell book, augmenting it judiciously, cross-referencing everything, and organizing it according to the most com

  18. Reference values for electrooculography

    International Nuclear Information System (INIS)

    Barrientos Castanno, Alberto; Herrera Mora, Maritza; Garcia Baez, Obel

    2012-01-01

    Obtain electrooculographic reference values based on the patterns set by the Standardization Committee of the International Society for Clinical Electrophysiology of Vision (ISCEV). the lowest amplitude values of the potential ranged between 388 and 882 μv in the dark phase. The light peak was obtained between 9 and 10 minutes, and during this phase the potential reached an amplitude ranging between 808 and 1 963 μv. This amplitude variability may be related to the fact that the test was conducted without pupillary mydriasis. The reference value obtained for Arden index was 1,55 to 2,87

  19. Dehydroepiandrosterone sulfate quantification in serum using high-performance liquid chromatography/mass spectrometry and a deuterated internal standard: a technique suitable for routine use or as a reference method

    International Nuclear Information System (INIS)

    Shackleton, C.H.; Kletke, C.; Wudy, S.; Pratt, J.H.

    1990-01-01

    A thermospray high-performance liquid chromatography/mass spectrometry method for determination of serum dehydroepiandrosterone sulfate is described. The steroid was measured intact using [7,7-2H2]dehydroepiandrosterone sulfate as internal standard. The analysis was carried out in the negative ion mode by determining the peak height ratio of the molecular anions of the analyte and internal standard. The method was used to determine the steroid in serum from 15 male and female normal adults and the following values were obtained: males, 272 +/- 45 micrograms/dl (range, 197 to 331 micrograms/dl) and females, 215 +/- 67 micrograms/dl (range, 107 to 347 micrograms/dl). In addition, dehydroepiandrosterone sulfate was measured by high-performance liquid chromatography/mass spectrometry and radioimmunoassay (a commercial kit) on 25 individuals of all age groups. There was strong correlation between the values obtained, but the radioimmunoassay values were generally double those obtained by high-performance liquid chromatography/mass spectrometry. Three other steroid sulfates, androsterone sulfate, epiandrosterone sulfate, and androst-5-ene-3 beta, 17 beta-diol sulfate, were also assayed. In males, these had mean values of 112, 44, and 13 micrograms/dl and, in females, they had mean values of 84, 25, and 6 micrograms/dl, respectively. Radioimmunoassay cross-reactivity measurement for these steroids (as reference compounds) showed that they were unlikely to contribute greatly to the discrepancy between radioimmunoassay and high-performance liquid chromatography/mass spectrometry values

  20. The effect of magnetic stimulation on the osteogenic and chondrogenic differentiation of human stem cells derived from the adipose tissue (hASCs)

    Energy Technology Data Exchange (ETDEWEB)

    Lima, João; Gonçalves, Ana I.; Rodrigues, Márcia T.; Reis, Rui L. [3Bs Research Group–Biomaterials, Biodegradables and Biomimetics, University of Minho, Guimarães (Portugal); ICVS/3Bs–PT Government Associate Laboratory, Braga/Guimarães (Portugal); Gomes, Manuela E., E-mail: megomes@dep.uminho.pt [3Bs Research Group–Biomaterials, Biodegradables and Biomimetics, University of Minho, Guimarães (Portugal); ICVS/3Bs–PT Government Associate Laboratory, Braga/Guimarães (Portugal)

    2015-11-01

    The use of magnetic nanoparticles (MNPs) towards the musculoskeletal tissues has been the focus of many studies, regarding MNPs ability to promote and direct cellular stimulation and orient tissue responses. This is thought to be mainly achieved by mechano-responsive pathways, which can induce changes in cell behavior, including the processes of proliferation and differentiation, in response to external mechanical stimuli. Thus, the application of MNP-based strategies in tissue engineering may hold potential to propose novel solutions for cell therapy on bone and cartilage strategies to accomplish tissue regeneration. The present work aims at studying the influence of MNPs on the osteogenic and chondrogenic differentiation of human adipose derived stem cells (hASCs). MNPs were incorporated in hASCs and cultured in medium supplemented for osteogenic and chondrogenic differentiation. Cultures were maintained up to 28 days with/without an external magnetic stimulus provided by a magnetic bioreactor, to determine if the MNPs alone could affect the osteogenic or chondrogenic phenotype of the hASCs. Results indicate that the incorporation of MNPs does not negatively affect the viability nor the proliferation of hASCs. Furthermore, Alizarin Red staining evidences an enhancement in extracellular (ECM) mineralization under the influence of an external magnetic field. Although not as evident as for osteogenic differentiation, Toluidine blue and Safranin-O stainings also suggest the presence of a cartilage-like ECM with glycosaminoglycans and proteoglycans under the magnetic stimulus provided. Thus, MNPs incorporated in hASCs under the influence of an external magnetic field have the potential to induce differentiation towards the osteogenic and chondrogenic lineages. - Highlights: • Cellular viability was not negatively influenced by the nanoparticles. • Chondrogenic medium influences more the synthesis of cartilage-like ECM than MNPs. • Synergetic effect among

  1. Genomic presence of gadD1 glutamate decarboxylase correlates with the organization of ascB-dapE internalin cluster in Listeria monocytogenes.

    Science.gov (United States)

    Chen, Jianshun; Fang, Chun; Zheng, Tianlun; Zhu, Ningyu; Bei, Yijiang; Fang, Weihuan

    2012-02-01

    The ability to survive and proliferate in acidic environments is a prerequisite for the infection of Listeria monocytogenes. The glutamate decarboxylase (GAD) system is responsible for acid resistance, and three GAD homologs have been identified in L. monocytogenes: gadD1, gadD2, and gadD3. To examine whether GAD genes are specific to lineage, serovar, or certain subpopulation, we performed a systematic investigation on the prevalence of GAD genes in 164 L. monocytogenes. In contrast to gadD2 and gadD3 conserved in all L. monocytogenes strains, gadD1 was identified in 36.6% (60/164) of L. monocytogenes strains, including all serovar 1/2c and 68.5% (37/54) of serovar 1/2a strains, as well as a small fraction of serovar 1/2b (3.4%, 1/29) and lineage III (13.8%, 4/29) strains. All serovar 4b and lineage IV strains lacked this gene. According to the ascB-dapE structure, L. monocytogenes strains were classified into four subpopulations, carrying inlC2DE, inlGC2DE, inlGHE, or no internalin cluster, respectively. All L. monocytogenes strains with inlGC2DE or inlGHE pattern harbored gadD1, whereas those bearing inlC2DE or no internalin cluster between ascB and dapE lacked gadD1. In addition, other five non-monocytogenes Listeria species lacking ascB-dapE internalin cluster were gadD1-negative. Overall, the presence of gadD1 is not fully dependent on lineages or serovars but correlates with ascB-dapE internalin profiles, suggesting gadD1 might have co-evolved with the ascB-dapE internalin cluster in the primitive L. monocytogenes before divergence of serovars.

  2. The effect of magnetic stimulation on the osteogenic and chondrogenic differentiation of human stem cells derived from the adipose tissue (hASCs)

    International Nuclear Information System (INIS)

    Lima, João; Gonçalves, Ana I.; Rodrigues, Márcia T.; Reis, Rui L.; Gomes, Manuela E.

    2015-01-01

    The use of magnetic nanoparticles (MNPs) towards the musculoskeletal tissues has been the focus of many studies, regarding MNPs ability to promote and direct cellular stimulation and orient tissue responses. This is thought to be mainly achieved by mechano-responsive pathways, which can induce changes in cell behavior, including the processes of proliferation and differentiation, in response to external mechanical stimuli. Thus, the application of MNP-based strategies in tissue engineering may hold potential to propose novel solutions for cell therapy on bone and cartilage strategies to accomplish tissue regeneration. The present work aims at studying the influence of MNPs on the osteogenic and chondrogenic differentiation of human adipose derived stem cells (hASCs). MNPs were incorporated in hASCs and cultured in medium supplemented for osteogenic and chondrogenic differentiation. Cultures were maintained up to 28 days with/without an external magnetic stimulus provided by a magnetic bioreactor, to determine if the MNPs alone could affect the osteogenic or chondrogenic phenotype of the hASCs. Results indicate that the incorporation of MNPs does not negatively affect the viability nor the proliferation of hASCs. Furthermore, Alizarin Red staining evidences an enhancement in extracellular (ECM) mineralization under the influence of an external magnetic field. Although not as evident as for osteogenic differentiation, Toluidine blue and Safranin-O stainings also suggest the presence of a cartilage-like ECM with glycosaminoglycans and proteoglycans under the magnetic stimulus provided. Thus, MNPs incorporated in hASCs under the influence of an external magnetic field have the potential to induce differentiation towards the osteogenic and chondrogenic lineages. - Highlights: • Cellular viability was not negatively influenced by the nanoparticles. • Chondrogenic medium influences more the synthesis of cartilage-like ECM than MNPs. • Synergetic effect among

  3. The effect of magnetic stimulation on the osteogenic and chondrogenic differentiation of human stem cells derived from the adipose tissue (hASCs)

    Science.gov (United States)

    Lima, João; Gonçalves, Ana I.; Rodrigues, Márcia T.; Reis, Rui L.; Gomes, Manuela E.

    2015-11-01

    The use of magnetic nanoparticles (MNPs) towards the musculoskeletal tissues has been the focus of many studies, regarding MNPs ability to promote and direct cellular stimulation and orient tissue responses. This is thought to be mainly achieved by mechano-responsive pathways, which can induce changes in cell behavior, including the processes of proliferation and differentiation, in response to external mechanical stimuli. Thus, the application of MNP-based strategies in tissue engineering may hold potential to propose novel solutions for cell therapy on bone and cartilage strategies to accomplish tissue regeneration. The present work aims at studying the influence of MNPs on the osteogenic and chondrogenic differentiation of human adipose derived stem cells (hASCs). MNPs were incorporated in hASCs and cultured in medium supplemented for osteogenic and chondrogenic differentiation. Cultures were maintained up to 28 days with/without an external magnetic stimulus provided by a magnetic bioreactor, to determine if the MNPs alone could affect the osteogenic or chondrogenic phenotype of the hASCs. Results indicate that the incorporation of MNPs does not negatively affect the viability nor the proliferation of hASCs. Furthermore, Alizarin Red staining evidences an enhancement in extracellular (ECM) mineralization under the influence of an external magnetic field. Although not as evident as for osteogenic differentiation, Toluidine blue and Safranin-O stainings also suggest the presence of a cartilage-like ECM with glycosaminoglycans and proteoglycans under the magnetic stimulus provided. Thus, MNPs incorporated in hASCs under the influence of an external magnetic field have the potential to induce differentiation towards the osteogenic and chondrogenic lineages.

  4. Code Verification Capabilities and Assessments in Support of ASC V&V Level 2 Milestone #6035

    Energy Technology Data Exchange (ETDEWEB)

    Doebling, Scott William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Budzien, Joanne Louise [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ferguson, Jim Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Harwell, Megan Louise [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hickmann, Kyle Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Israel, Daniel M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Magrogan, William Richard III [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Singleton, Jr., Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Srinivasan, Gowri [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Walter, Jr, John William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woods, Charles Nathan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-26

    This document provides a summary of the code verification activities supporting the FY17 Level 2 V&V milestone entitled “Deliver a Capability for V&V Assessments of Code Implementations of Physics Models and Numerical Algorithms in Support of Future Predictive Capability Framework Pegposts.” The physics validation activities supporting this milestone are documented separately. The objectives of this portion of the milestone are: 1) Develop software tools to support code verification analysis; 2) Document standard definitions of code verification test problems; and 3) Perform code verification assessments (focusing on error behavior of algorithms). This report and a set of additional standalone documents serve as the compilation of results demonstrating accomplishment of these objectives.

  5. The deoxyhypusine synthase mutant dys1-1 reveals the association of eIF5A and Asc1 with cell wall integrity.

    Directory of Open Access Journals (Sweden)

    Fabio Carrilho Galvão

    Full Text Available The putative eukaryotic translation initiation factor 5A (eIF5A is a highly conserved protein among archaea and eukaryotes that has recently been implicated in the elongation step of translation. eIF5A undergoes an essential and conserved posttranslational modification at a specific lysine to generate the residue hypusine. The enzymes deoxyhypusine synthase (Dys1 and deoxyhypusine hydroxylase (Lia1 catalyze this two-step modification process. Although several Saccharomyces cerevisiae eIF5A mutants have importantly contributed to the study of eIF5A function, no conditional mutant of Dys1 has been described so far. In this study, we generated and characterized the dys1-1 mutant, which showed a strong depletion of mutated Dys1 protein, resulting in more than 2-fold decrease in hypusine levels relative to the wild type. The dys1-1 mutant demonstrated a defect in total protein synthesis, a defect in polysome profile indicative of a translation elongation defect and a reduced association of eIF5A with polysomes. The growth phenotype of dys1-1 mutant is severe, growing only in the presence of 1 M sorbitol, an osmotic stabilizer. Although this phenotype is characteristic of Pkc1 cell wall integrity mutants, the sorbitol requirement from dys1-1 is not associated with cell lysis. We observed that the dys1-1 genetically interacts with the sole yeast protein kinase C (Pkc1 and Asc1, a component of the 40S ribosomal subunit. The dys1-1 mutant was synthetically lethal in combination with asc1Δ and overexpression of TIF51A (eIF5A or DYS1 is toxic for an asc1Δ strain. Moreover, eIF5A is more associated with translating ribosomes in the absence of Asc1 in the cell. Finally, analysis of the sensitivity to cell wall-perturbing compounds revealed a more similar behavior of the dys1-1 and asc1Δ mutants in comparison with the pkc1Δ mutant. These data suggest a correlated role for eIF5A and Asc1 in coordinating the translational control of a subset of m

  6. Instant standard concept for data standards development

    NARCIS (Netherlands)

    Folmer, Erwin Johan Albert; Kulcsor, Istvan Zsolt; Roes, Jasper

    2013-01-01

    This paper presents the current results of an ongoing research about a new data standards development concept. The concept is called Instant Standard referring to the pressure that is generated by shrinking the length of the standardization process. Based on this concept it is estimated that the

  7. Engineering anatomically shaped vascularized bone grafts with hASCs and 3D-printed PCL scaffolds.

    Science.gov (United States)

    Temple, Joshua P; Hutton, Daphne L; Hung, Ben P; Huri, Pinar Yilgor; Cook, Colin A; Kondragunta, Renu; Jia, Xiaofeng; Grayson, Warren L

    2014-12-01

    The treatment of large craniomaxillofacial bone defects is clinically challenging due to the limited availability of transplantable autologous bone grafts and the complex geometry of the bones. The ability to regenerate new bone tissues that faithfully replicate the anatomy would revolutionize treatment options. Advances in the field of bone tissue engineering over the past few decades offer promising new treatment alternatives using biocompatible scaffold materials and autologous cells. This approach combined with recent advances in three-dimensional (3D) printing technologies may soon allow the generation of large, bioartificial bone grafts with custom, patient-specific architecture. In this study, we use a custom-built 3D printer to develop anatomically shaped polycaprolactone (PCL) scaffolds with varying internal porosities. These scaffolds are assessed for their ability to support induction of human adipose-derived stem cells (hASCs) to form vasculature and bone, two essential components of functional bone tissue. The development of functional tissues is assessed in vitro and in vivo. Finally, we demonstrate the ability to print large mandibular and maxillary bone scaffolds that replicate fine details extracted from patient's computed tomography scans. The findings of this study illustrate the capabilities and potential of 3D printed scaffolds to be used for engineering autologous, anatomically shaped, vascularized bone grafts. © 2014 Wiley Periodicals, Inc.

  8. ASCE application guide for recommended practice for fiber-reinforced polymer products for overhead utility line structures

    Energy Technology Data Exchange (ETDEWEB)

    Gnandt, E. [T and D High Voltage Consulting, Vancouver, BC (Canada)

    2002-07-01

    The participants to the American Society of Civil Engineers (ASCE) prepared an application guide to provide guidelines to utilities and manufacturers on topics ranging from design to manufacture, testing and installation of fiber-reinforced polymer (FRP) products. The intent was also to help utilities with a possible replacement material for wood, steel and pre-stressed concrete. FRP products are constructed from fiber and resin and offer several advantages such as light weight and high strength-to-weight ratio, low maintenance, dimensional stability, resistance to rot, corrosion, chemicals and pest damage. FRP products can be used for lighting poles, ladders and grating, transformer pads, pole line hardware and crossarms, and other applications. There are five structural configurations: (1) cantilevered structures (single pole), (2) guyed structures, framed structures (H-Frame), (4) a combination of (1), (2), and (3), and (5) lattice structures (transmission class). The author listed some of the initial considerations: physical characteristics, guying and grounding, deflection and load testing, attached items, and durability to name only a few. The materials and manufacturing processes were briefly explained, namely the pultrusion method, the filament winding method, and the centrifugal casting method. Design loads considerations are discussed, as are performance-based criteria such as mechanical, coating durability and electrical. Quality control, assembly erection and storage, and in-service considerations are also discussed. The author concluded the presentation with a section dealing with field inspections. figs.

  9. Transcriptional signature of human adipose tissue-derived stem cells (hASCs) preconditioned for chondrogenesis in hypoxic conditions

    International Nuclear Information System (INIS)

    Pilgaard, L.; Lund, P.; Duroux, M.; Lockstone, H.; Taylor, J.; Emmersen, J.; Fink, T.; Ragoussis, J.; Zachar, V.

    2009-01-01

    Hypoxia is an important factor involved in the control of stem cells. To obtain a better insight into the phenotypical changes brought about by hypoxic preconditioning prior to chondrogenic differentiation; we have investigated growth, colony-forming and chondrogenic capacity, and global transcriptional responses of six adipose tissue-derived stem cell lines expanded at oxygen concentrations ranging from ambient to 1%. The assessment of cell proliferation and colony-forming potential revealed that the hypoxic conditions corresponding to 1% oxygen played a major role. The chondrogenic inducibility, examined by high-density pellet model, however, did not improve on hypoxic preconditioning. While the microarray analysis revealed a distinctive inter-donor variability, the exposure to 1% hypoxia superseded the biological variability and produced a specific expression profile with 2581 significantly regulated genes and substantial functional enrichment in the pathways of cell proliferation and apoptosis. Additionally, exposure to 1% oxygen resulted in upregulation of factors related to angiogenesis and cell growth. In particular, leptin (LEP), the key regulator of body weight and food intake was found to be highly upregulated. In conclusion, the results of this investigation demonstrate the significance of donor demographics and the importance of further studies into the use of regulated oxygen tension as a tool for preparation of ASCs in order to exploit their full potential.

  10. Consumo de ácido ascórbico y niveles séricos en hombres adultos fumadores y no fumadores de la CD. de Hermosillo, Sonora, México

    OpenAIRE

    Méndez E, Rosa Olivia; Wyatt, C. Jane; Saavedra, Javier; Ornelas, Alicia

    2002-01-01

    El ácido ascórbico es uno de las antioxidantes más importantes a nivel extracelular, sin embargo su papel preventivo de enfermedades degenerativas se puede comprometer al disminuir sus niveles séricos. Bajos valores de ácido ascórbico sérico se han reportado en hombres fumadores. En el presente estudio se estimó la ingestión de ácido ascórbico en 25 hombres adultos sanos de Hermosillo, Sonora, México, divididos en dos grupos: fumadores y no fumadores; se compararon los niveles séricos de ácid...

  11. Genetic diversity of internalin genes in the ascB-dapE locus among Listeria monocytogenes lineages III and IV strains.

    Science.gov (United States)

    Chen, Jianshun; Cheng, Changyong; Lv, Yonghui; Fang, Weihuan

    2013-09-01

    Listeria monocytogenes is an important foodborne pathogen encompassing four phylogenetic lineages. Lineages III and IV are rare, but have been reported to show considerable biodiversity, providing important clues for the evolutionary history in Listeria. In this study, analysis of the ascB-dapE locus reveals genetic diversity in lineages III and IV, and is consistent with the classification of sublineages. Four of the six genetic patterns (two of sublineage IIIC and two of lineage IV) are specific to these two lineages. The ascB-dapE locus suggests a hot spot for genome diversification, and serves as an attractive molecular marker for better understanding of the biodiversity and population structure of lineages III and IV strains. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Network protocol changes can improve DisCom WAN performance : evaluating TCP modifications and SCTP in the ASC tri-lab environment.

    Energy Technology Data Exchange (ETDEWEB)

    Tolendino, Lawrence F.; Hu, Tan Chang

    2005-06-01

    The Advanced Simulation and Computing (ASC) Distance Computing (DisCom) Wide Area Network (WAN) is a high performance, long distance network environment that is based on the ubiquitous TCP/IP protocol set. However, the Transmission Control Protocol (TCP) and the algorithms that govern its operation were defined almost two decades ago for a network environment vastly different from the DisCom WAN. In this paper we explore and evaluate possible modifications to TCP that purport to improve TCP performance in environments like the DisCom WAN. We also examine a much newer protocol, SCTP (Stream Control Transmission Protocol) that claims to provide reliable network transport while also implementing multi-streaming, multi-homing capabilities that are appealing in the DisCom high performance network environment. We provide performance comparisons and recommendations for continued development that will lead to network communications protocol implementations capable of supporting the coming ASC Petaflop computing environments.

  13. ASC-J9 Suppresses Castration-Resistant Prostate Cancer Growth through Degradation of Full-length and Splice Variant Androgen Receptors

    Directory of Open Access Journals (Sweden)

    Shinichi Yamashita

    2012-01-01

    Full Text Available Early studies suggested androgen receptor (AR splice variants might contribute to the progression of prostate cancer (PCa into castration resistance. However, the therapeutic strategy to target these AR splice variants still remains unresolved. Through tissue survey of tumors from the same patients before and after castration resistance, we found that the expression of AR3, a major AR splice variant that lacks the AR ligand-binding domain, was substantially increased after castration resistance development. The currently used antiandrogen, Casodex, showed little growth suppression in CWR22Rv1 cells. Importantly, we found that AR degradation enhancer ASC-J9 could degrade both full-length (fAR and AR3 in CWR22Rv1 cells as well as in C4-2 and C81 cells with addition of AR3. The consequences of such degradation of both fAR and AR3 might then result in the inhibition of AR transcriptional activity and cell growth in vitro. More importantly, suppression of AR3 specifically by short-hairpin AR3 or degradation of AR3 by ASC-J9 resulted in suppression of AR transcriptional activity and cell growth in CWR22Rv1-fARKD (fAR knockdown cells in which DHT failed to induce, suggesting the importance of targeting AR3. Finally, we demonstrated the in vivo therapeutic effects of ASC-J9 by showing the inhibition of PCa growth using the xenografted model of CWR22Rv1 cells orthotopically implanted into castrated nude mice with undetectable serum testosterone. These results suggested that targeting both fAR- and AR3-mediated PCa growth by ASC-J9 may represent the novel therapeutic approach to suppress castration-resistant PCa. Successful clinical trials targeting both fAR and AR3 may help us to battle castration-resistant PCa in the future.

  14. ASC ATDM Level 2 Milestone #5325: Asynchronous Many-Task Runtime System Analysis and Assessment for Next Generation Platforms.

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Gavin Matthew; Bettencourt, Matthew Tyler; Bova, Steven W.; Franko, Ken; Gamell, Marc; Grant, Ryan; Hammond, Simon David; Hollman, David S; Knight, Samuel; Kolla, Hemanth; Lin, Paul; Olivier, Stephen Lecler; Sjaardema, Gregory D.; Slattengren, Nicole Lemaster; Teranishi, Keita; Wilke, Jeremiah J; Bennett, Janine Camille; Clay, Robert L.; Kale, Laxkimant; Jain, Nikhil; Mikida, Eric; Aiken, Alex; Bauer, Michael; Lee, Wonchan; Slaughter, Elliott; Treichler, Sean; Berzins, Martin; Harman, Todd; Humphreys, Alan; Schmidt, John; Sunderland, Dan; Mccormick, Pat; Gutierrez, Samuel; Shulz, Martin; Gamblin, Todd; Bremer, Peer-Timo

    2015-09-01

    This report provides in-depth information and analysis to help create a technical road map for developing next- generation Orogramming mocleN and runtime systemsl that support Advanced Simulation and Computing (ASC) work- load requirements. The focus herein is on 4synchronous many-task (AMT) model and runtime systems, which are of great interest in the context of "Oriascale7 computing, as they hold the promise to address key issues associated with future extreme-scale computer architectures. This report includes a thorough qualitative and quantitative examination of three best-of-class AIM] runtime systemsHCharm-HE, Legion, and Uintah, all of which are in use as part of the Centers. The studies focus on each of the runtimes' programmability, performance, and mutability. Through the experiments and analysis presented, several overarching Predictive Science Academic Alliance Program II (PSAAP-II) Ascl findings emerge. From a performance perspective, AIVT11runtimes show tremendous potential for addressing extreme- scale challenges. Empirical studies show an AM11 runtime can mitigate performance heterogeneity inherent to the machine itself and that Message Passing Interface (MP1) and AM11runtimes perform comparably under balanced con- ditions. From a programmability and mutability perspective however, none of the runtimes in this study are currently ready for use in developing production-ready Sandia ASCIapplications. The report concludes by recommending a co- design path forward, wherein application, programming model, and runtime system developers work together to define requirements and solutions. Such a requirements-driven co-design approach benefits the community as a whole, with widespread community engagement mitigating risk for both application developers developers. and high-performance computing inntime systein

  15. Report of experiments and evidence for ASC L2 milestone 4467 : demonstration of a legacy application's path to exascale.

    Energy Technology Data Exchange (ETDEWEB)

    Curry, Matthew L.; Ferreira, Kurt Brian; Pedretti, Kevin Thomas Tauke; Leung, Vitus Joseph; Moreland, Kenneth D.; Lofstead, Gerald Fredrick, II; Gentile, Ann C. (Sandia National Laboratories, Livermore, CA); Klundt, Ruth Ann; Ward, H. Lee; Laros, James H., III; Hemmert, Karl Scott; Fabian, Nathan D.; Levenhagen, Michael J.; Barrett, Brian W.; Brightwell, Ronald Brian; Barrett, Richard; Wheeler, Kyle Bruce; Kelly, Suzanne Marie; Rodrigues, Arun F.; Brandt, James M. (Sandia National Laboratories, Livermore, CA); Thompson, David (Sandia National Laboratories, Livermore, CA); VanDyke, John P.; Oldfield, Ron A.; Tucker, Thomas (Open Grid Computing, Inc., Austin, TX); Vaughan, Courtenay Thomas

    2012-03-01

    This report documents thirteen of Sandia's contributions to the Computational Systems and Software Environment (CSSE) within the Advanced Simulation and Computing (ASC) program between fiscal years 2009 and 2012. It describes their impact on ASC applications. Most contributions are implemented in lower software levels allowing for application improvement without source code changes. Improvements are identified in such areas as reduced run time, characterizing power usage, and Input/Output (I/O). Other experiments are more forward looking, demonstrating potential bottlenecks using mini-application versions of the legacy codes and simulating their network activity on Exascale-class hardware. The purpose of this report is to prove that the team has completed milestone 4467-Demonstration of a Legacy Application's Path to Exascale. Cielo is expected to be the last capability system on which existing ASC codes can run without significant modifications. This assertion will be tested to determine where the breaking point is for an existing highly scalable application. The goal is to stretch the performance boundaries of the application by applying recent CSSE RD in areas such as resilience, power, I/O, visualization services, SMARTMAP, lightweight LWKs, virtualization, simulation, and feedback loops. Dedicated system time reservations and/or CCC allocations will be used to quantify the impact of system-level changes to extend the life and performance of the ASC code base. Finally, a simulation of anticipated exascale-class hardware will be performed using SST to supplement the calculations. Determine where the breaking point is for an existing highly scalable application: Chapter 15 presented the CSSE work that sought to identify the breaking point in two ASC legacy applications-Charon and CTH. Their mini-app versions were also employed to complete the task. There is no single breaking point as more than one issue was found with the two codes. The results were

  16. A reference tristimulus colorimeter

    Science.gov (United States)

    Eppeldauer, George P.

    2002-06-01

    A reference tristimulus colorimeter has been developed at NIST with a transmission-type silicon trap detector (1) and four temperature-controlled filter packages to realize the Commission Internationale de l'Eclairage (CIE) x(λ), y(λ) and z(λ) color matching functions (2). Instead of lamp standards, high accuracy detector standards are used for the colorimeter calibration. A detector-based calibration procedure is being suggested for tristimulus colorimeters wehre the absolute spectral responsivity of the tristimulus channels is determined. Then, color (spectral) correct and peak (amplitude) normalization are applied to minimize uncertainties caused by the imperfect realizations of the CIE functions. As a result of the corrections, the chromaticity coordinates of stable light sources with different spectral power distributions can be measured with uncertainties less than 0.0005 (k=1).

  17. ASC Weekly News Notes

    Energy Technology Data Exchange (ETDEWEB)

    Womble, David E.

    2016-05-01

    Unified collision operator demonstrated for both radiation transport and PIC-DSMC. A side-by-side comparison between the DSMC method and the radiation transport method was conducted for photon attenuation in the atmosphere over 2 kilometers in physical distance with a reduction of photon density of six orders of magnitude. Both DSMC and traditional radiation transport agreed with theory to two digits. This indicates that PIC-DSMC operators can be unified with the radiation transport collision operators into a single code base and that physics kernels can remain unique to the actual collision pairs. This simulation example provides an initial validation of the unified collision theory approach that will later be implemented into EMPIRE.

  18. Martian Chemical and Isotopic Reference Standards in Earth-based Laboratories — An Invitation for Geochemical, Astrobiological, and Engineering Dialog on Considering a Weathered Chondrite for Mars Sample Return.

    Science.gov (United States)

    Ashley, J. W.; Tait, A. W.; Velbel, M. A.; Boston, P. J.; Carrier, B. L.; Cohen, B. A.; Schröder, C.; Bland, P.

    2017-12-01

    Exogenic rocks (meteorites) found on Mars 1) have unweathered counterparts on Earth; 2) weather differently than indigenous rocks; and 3) may be ideal habitats for putative microorganisms and subsequent biosignature preservation. These attributes show the potential of meteorites for addressing hypothesis-driven science. They raise the question of whether chondritic meteorites, of sufficient weathering intensity, might be considered as candidates for sample return in a potential future mission. Pursuant to this discussion are the following questions. A) Is there anything to be learned from the laboratory study of a martian chondrite that cannot be learned from indigenous materials; and if so, B) is the science value high enough to justify recovery? If both A and B answer affirmatively, then C) what are the engineering constraints for sample collection for Mars 2020 and potential follow-on missions; and finally D) what is the likelihood of finding a favorable sample? Observations relevant to these questions include: i) Since 2005, 24 candidate and confirmed meteorites have been identified on Mars at three rover landing sites, demonstrating their ubiquity and setting expectations for future finds. All have been heavily altered by a variety of physical and chemical processes. While the majority of these are irons (not suitable for recovery), several are weathered stony meteorites. ii) Exogenic reference materials provide the only chemical/isotope standards on Mars, permitting quantification of alteration rates if residence ages can be attained; and possibly enabling the removal of Late Amazonian weathering overprints from other returned samples. iii) Recent studies have established the habitability of chondritic meteorites with terrestrial microorganisms, recommending their consideration when exploring astrobiological questions. High reactivity, organic content, and permeability show stony meteorites to be more attractive for colonization and subsequent biosignature

  19. Efeitos do ácido ascórbico nos biomarcadores de estresse oxidativo em nadadores de elite

    Directory of Open Access Journals (Sweden)

    Monike Garlipp-Picchi

    2013-12-01

    Full Text Available OBJETIVO: O objetivo do estudo foi verificar os efeitos da oferta de vitamina C através de um suplemento alimentar e dieta rica em ácido ascórbico (AA no estresse oxidativo induzido pelo exercício. MÉTODOS: A amostra foi composta por 13 nadadores de elite (seis homens e sete mulheres com idades entre 18 e 26 anos. Os mesmos atletas foram submetidos a sessão de exercício agudo em três fases, com diferentes tratamentos: controle (C, dieta rica em AA (D e suplemento de AA (S, nas quais amostras de sangue foram colhidas antes, imediatamente após e 24 horas depois do exercício. Para comparação entre as fases e etapas foi utilizado o modelo de regressão linear com efeitos mistos. RESULTADOS: O consumo alimentar habitual de antioxidantes não foi diferente entre as fases, apenas a ingestão de AA foi maior na fase D e S em relação à fase C. O uso de dieta rica em AA favoreceu uma menor peroxidação lipídica, devido aos menores valores de hidroperóxidos lipídicos (FOX, diminuição da peroxidação após exercício, pela diminuição de substâncias reativas ao ácido tiobarbitúrico (TBARS e aumento dos níveis de vitamina C logo após o exercício. O uso de suplemento de AA também conteve a peroxidação lipídica após exercício e aumentou o poder antioxidante, devido aos maiores níveis de glutationa reduzida (GSH. Sem adição de AA os nadadores tiveram um maior dano hepático, pois apresentaram maiores níveis de transaminase-glutâmico-oxalacética (TGO, menores níveis de antioxidantes (vitamina C e GSH e aumento do ácido úrico. CONCLUSÃO: Assim, as mudanças observadas com a adição de AA à dieta de nadadores sugerem um importante papel deste micronutriente na defesa contra o estresse oxidativo induzido pelo exercício.

  20. Antocianinas, ácido ascórbico, polifenoles totales y actividad antioxidante, en la cáscara de camu-camu (Myrciaria dubia (H.B.K McVaugh Antocianinas, ácido ascórbico, polifenóis totais e atividade antioxidante na casca do camu-camu (Myrciaria dubia (H.B.K McVaugh

    Directory of Open Access Journals (Sweden)

    Juan Edson Villanueva-Tiburcio

    2010-05-01

    Full Text Available Este trabajo fue realizado en la UNAS, Tingo María, Perú. Los objetivos fueron evaluar el contenido de antocianinas, ácido ascórbico, y polifenoles totales, en la cáscara fresca y seca de camu-camu (Myrciaria dubia (H.B.K McVaugh en diferentes estados de madurez; evaluar la actividad antioxidante en la cáscara seca, usando diferentes tipos de radicales (DPPH, ABTS+ y Peroxilo y correlacionar el valor de ácido ascórbico y polifenoles totales con la actividad antioxidante. La extracción fue realizada en medio acuoso, y los resultados de las evaluaciones de cada experimento fueron analizados por un diseño completamente al azar (DCA, según la prueba de t-student (p A pesquisa foi realizada na UNAS em Tingo Maria, Peru, teve como objetivos: avaliar o teor de antocianinas, ácido ascórbico e polifenóis totais, na casca fresca e na casca seca do camu-camu (Myrciaria dubia (HBK McVaugh em diferentes tempos de maturação; avaliar a atividade antioxidante na casca seca utilizando diferentes tipos de radicais (DPPH, ABTS+ e Peroxilo e correlacionar o teor de ácido ascórbico e polifenóis totais com a atividade antioxidante. A extraç��o foi realizada em meio aquoso, os resultados das avaliações de cada experiência são analisados no delineamento inteiramente casualizado (DIC, pelo teste de t-student (p < 0,05. O extrato da casca da amostra madura fresca apresentou as concentrações mais elevadas de ácido ascórbico e de antocianinas em relação a meio madura e verde, com 21,95 mg.g-1 de casca e 46,42 mg.L-1 de cianidin-3-glucosídeo, respectivamente, enquanto que o extrato da casca seca meio madura apresentou o maior teor de ácido ascórbico em relação a madura e verde (53,49 mg.g-1 e de polifenóis totais: 7,70 mg Ác. Gálico/g. A maior atividade antioxidante foi encontrada no extrato da casca seca da amostra meio madura com IC50 = 46,20; 20,25 e 8,30 μg.mL-1, em comparação com DPPH radical, ABTS+ e Perox