WorldWideScience

Sample records for artificially elevated intraocular

  1. Visual functional changes during acute elevation of intraocular pressure

    Institute of Scientific and Technical Information of China (English)

    Tian-De SHOU

    2006-01-01

    Glaucoma is closely related to elevation of intraocular pressure (IOP). Many studies have done on the effect of chronic elevation of IOP on the retina and optic nerve, but less attention was paid to the effect of acute elevated IOP. Here we briefly review experimental studies on functional changes of the visual system from the retina to the visual cortex under acute elevated IOP condition, which is similar to that of acute primary angle-closure glaucoma.

  2. Blood pressure modifies retinal susceptibility to intraocular pressure elevation.

    Directory of Open Access Journals (Sweden)

    Zheng He

    Full Text Available Primary open angle glaucoma affects more than 67 million people. Elevated intraocular pressure (IOP is a risk factor for glaucoma and may reduce nutrient availability by decreasing ocular perfusion pressure (OPP. An interaction between arterial blood pressure and IOP determines OPP; but the exact contribution that these factors have for retinal function is not fully understood. Here we sought to determine how acute modifications of arterial pressure will affect the susceptibility of neuronal function and blood flow to IOP challenge. Anaesthetized (ketamine:xylazine Long-Evan rats with low (∼60 mmHg, sodium nitroprusside infusion, moderate (∼100 mmHg, saline, or high levels (∼160 mmHg, angiotensin II of mean arterial pressure (MAP, n = 5-10 per group were subjected to IOP challenge (10-120 mmHg, 5 mmHg steps every 3 minutes. Electroretinograms were measured at each IOP step to assess bipolar cell (b-wave and inner retinal function (scotopic threshold response or STR. Ocular blood flow was measured using laser-Doppler flowmetry in groups with similar MAP level and the same IOP challenge protocol. Both b-wave and STR amplitudes decreased with IOP elevation. Retinal function was less susceptible to IOP challenge when MAP was high, whereas the converse was true for low MAP. Consistent with the effects on retinal function, higher IOP was needed to attenuated ocular blood flow in animals with higher MAP. The susceptibility of retinal function to IOP challenge can be ameliorated by acute high BP, and exacerbated by low BP. This is partially mediated by modifications in ocular blood flow.

  3. Metabolic Syndrome as a Risk Factor for Elevated Intraocular Pressure

    OpenAIRE

    Sahinoglu-Keskek, Nedime; Keskek, Sakir Ozgur; Cevher, Selim; Kirim, Sinan; Kayiklik, Asim; Ortoglu, Gulay; Saler, Tayyibe

    2014-01-01

    Objective: The aim of this study was to investigate the association between intraocular pressure and metabolic syndrome by comparing central corneal thicknesses. Methods: One hundred sixty-two subjects were enrolled in this cross-sectional study, with 89 subjects in a metabolic syndrome group and 73 subjects in a control group. Ophthalmological examinations, including intraocular pressure and central corneal thickness measurements, were performed on each subject. Serum fasting glucose, trigly...

  4. Clinical Analysis of Early and Mid-late Elevated Intraocular Pressure after Silicone Oil Injection

    Institute of Scientific and Technical Information of China (English)

    Lifei Wang; Jingjiang Liu; Tianxiang Lu

    2014-01-01

    Purpose:To discuss the incidence and clinical features of early and mid-late elevated intraocular pressure after pars plana vitrectomy and silicone oil injection, and to evaluate the clinical management of eyes with secondary glaucoma. Methods:.This was an observational consecutive case series of 691 eyes in 679 patients who were treated with pars plana vitrectomy and silicone injection...The diagnostic criteria of early elevated intraocular pressure after silicone oil injection was ≥21 mmHg two weeks after surgery, while mid-late ele-vated intraocular pressure was ≥21 mmHg after two weeks. The incidence and clinical management of elevated intraocular pressure were analyzed. Results: In total, 211 of 691 eyes (30.54%) developed ele-vated intraocular pressure two weeks after pars plana vitrecto my and silicone injection. Of the 211 eyes, 101 eyes (47.87%) had ocular inflammation, 64 eyes (30.33%) showed hyphema, 35 eyes(16.59%) had silicone oil in the anterior chamber, 6 eyes. (2.84% ).had excess silicone oil injected,.and 5 eyes (2.37%).had rubeosis irides. Eighty three of 691 eyes (12.01%). developed elevated intraocular pressure after two weeks..Of these 83 eyes, 25 eyes (30.12%) had rubeosis irides,.16 eyes (19.27%) had issues related to topic steroid therapy,.13 eyes . (15.66%).had a papillary block,.silicone oil in the anterior chamber,10 eyes (12.05%) had a silicone emulsion,.10 eyes (12.05% ).had peripheral anterior synchiae,.and 9 eyes (10.84%).had silicone oil in the anterior chamber..All eyes with elevated intraocular pressure were treated with antiglau-coma medications and surgeries. Conclusion:.The reasons for elevated intraocular pressure dif-fered between early and mid-late after pars plana vitrectomy and silicone oil injection. The elevated intraocular pressure can be controlled effectively by immediate diagnosis and proper treatment with medicine and operation.

  5. Using the Electroretinogram to Understand How Intraocular Pressure Elevation Affects the Rat Retina

    Directory of Open Access Journals (Sweden)

    Bang V. Bui

    2013-01-01

    Full Text Available Intraocular pressure (IOP elevation is a key risk factor for glaucoma. Our understanding of the effect that IOP elevation has on the eye has been greatly enhanced by the application of the electroretinogram (ERG. In this paper, we describe how the ERG in the rodent eye is affected by changes in IOP magnitude, duration, and number of spikes. We consider how the variables of blood pressure and age can modify the effect of IOP elevation on the ERG. Finally, we contrast the effects that acute and chronic IOP elevation can have on the rodent ERG.

  6. Evaulation of Incidence and Risk Factors for Intraocular Pressure Elevation After Intravitreal Triamcinolone Acetonide Injection

    Directory of Open Access Journals (Sweden)

    Didar Uçar

    2015-05-01

    Full Text Available Objectives: To investigate the effect of intravitreal triamcinolone acetonide (IVTA used for the macular edema on intraocular pressure (IOP and to determine the risk factors for IOP elevation. Materials and Methods: This retrospective study included 93 eyes of 85 patients who had 4 mg intravitreal triamcinolone injection. Of the 85 patients, 56 (65.8% had diabetic macular edema, 22 (25.8% had branch retinal, and 7 (8.2% had central retinal vein occlusion. IOP changes after injection as well as the relation between IOP elevation and age, sex, lens status, etiology of macular edema, baseline IOP were evaluated. Results: Fourty-six male and 39 female patients with mean age 61.58±9.5 years were evaluated. IOP was recorded to be >24 mmHg in 30 eyes (32.2% at follow-up visit after an average of 7.5 weeks. Normalization of IOP with medication was achieved in all IOP elevated eyes. Fifteen of 29 eyes (51.7% with vein occlusion and 15 of 64 eyes (23.3% with diabetic macula edema had IOP elevation (p=0.01. Twenty-six of 73 phakic (35.6% and 4 of 20 pseudophakic eyes (20% had IOP >24 mmHg (p=0.16. There was no association between IOP elevation and sex (p=0.33. Baseline IOP was 16.47±2.8 mmHg in eyes which had elevated IOP and 14.78±2.4 mmHg in the remaining. There was significant relation between IOP elevation and baseline IOP level (p=0.01. Conclusion: Elevated IOP is common side effect after IVTA, but normalization is usually achieved by topical medication. Patients with baseline IOP ≥15 mmHg and vein occlusion have higher risk for IOP elevation. (Turk J Ophthalmol 2015; 45: 86-91

  7. Brinzolamide nanocrystal formulations for ophthalmic delivery: reduction of elevated intraocular pressure in vivo.

    Science.gov (United States)

    Tuomela, Annika; Liu, Peng; Puranen, Jooseppi; Rönkkö, Seppo; Laaksonen, Timo; Kalesnykas, Giedrius; Oksala, Olli; Ilkka, Jukka; Laru, Johanna; Järvinen, Kristiina; Hirvonen, Jouni; Peltonen, Leena

    2014-06-01

    Nanocrystal-based drug delivery systems provide important tools for ocular formulation development, especially when considering poorly soluble drugs. The objective of the study was to formulate ophthalmic, intraocular pressure (IOP) reducing, nanocrystal suspensions from a poorly soluble drug, brinzolamide (BRA), using a rapid wet milling technique, and to investigate their IOP reducing effect in vivo. Different stabilizers for the nanocrystals were screened (hydroxypropyl methylcellulose (HPMC), poloxamer F127 and F68, polysorbate 80) and HPMC was found to be the only successful stabilizer. In order to investigate both the effect of an added absorption enhancer (polysorbate 80) and the impact of the free drug in the nanocrystal suspension, formulations in phosphate buffered saline (PBS) at pH 7.4 and pH 4.5 were prepared. Particle size, polydispersity (PI), solid state (DSC), morphology (SEM) as well as dissolution behavior and the uniformity of the formulations were characterized. There was rapid dissolution of BRA (in PBS pH 7.4) from all the nanocrystal formulations; after 1 min 100% of the drug was fully dissolved. The effect was significantly pronounced at pH 4.5, where the dissolved fraction of drug was the highest. The cytotoxicity of nanocrystal formulations to human corneal epithelial cell (HCE-T) viability was tested. The effects of the nanocrystal formulations and the commercial product on the cell viability were comparable. The intraocular pressure (IOP) lowering effect was investigated in vivo using a modern rat ocular hypertensive model and elevated IOP reduction was seen in vivo with all the formulations. Notably, the reduction achieved in experimentally elevated IOP was comparable to that obtained with a marketed product. In conclusion, various BRA nanocrystal formulations, which all showed advantageous dissolution and absorption behavior, were successfully formulated. PMID:24680962

  8. Clinical Analysis of 106 Cases with Elevated Intraocular Pressure in Thyroid-associated Ophthalmopathy

    Institute of Scientific and Technical Information of China (English)

    Jianfeng He; Zhongyao Wu; Jianhua Yan; Huasheng Yang; Yuxiang Mao; Siming Ai; Zhicong Chen

    2004-01-01

    Purpose :To summarize the clinical manifestation of thyroid-associated ophthalmopathy (TAO) with elevated intraocular pressure (IOP), and to analyze the contributing factors.Methods: One hundred and six cases(188 eyes) of ocular hypertension in 339 cases(597eyes) with TAO were collected from 1994 to 2001 and their clinic manifestations were summarized and analyzed.Results:It was demonstrated that the incidence of ocular hypertension in TAO was 31.3%, and was more frequently found in the male than in the female. The elevated IOP in TAO was found to be partially related to compression of the eyeball by enlarged extraocular muscles, the elevated intraorbital pressure as result of the proliferation of intraorbital connective tissue and the enlargement as well as swelling of extraocular muscles. It was also related to the severity of TAO other than the course of TAO. The ocular hypertension in most cases can be controlled with reduction of IOP by methylprednisolone or orbital decompression.Conclusion: Specific clinical features were found in TAO patients with ocular hypertension. It should be differentiated with primary glaucoma. The IOP in most cases can be controlled by prompt and effective treatment of TAO. Eye Science 2004;20:10-14.

  9. Modelling survival after treatment of intraocular melanoma using artificial neural networks and Bayes theorem

    International Nuclear Information System (INIS)

    This paper describes the development of an artificial intelligence (AI) system for survival prediction from intraocular melanoma. The system used artificial neural networks (ANNs) with five input parameters: coronal and sagittal tumour location, anterior tumour margin, largest basal tumour diameter and the cell type. After excluding records with missing data, 2331 patients were included in the study. These were split randomly into training and test sets. Date censorship was applied to the records to deal with patients who were lost to follow-up and patients who died from general causes. Bayes theorem was then applied to the ANN output to construct survival probability curves. A validation set with 34 patients unseen to both training and test sets was used to compare the AI system with Cox's regression (CR) and Kaplan-Meier (KM) analyses. Results showed large differences in the mean 5 year survival probability figures when the number of records with matching characteristics was small. However, as the number of matches increased to >100 the system tended to agree with CR and KM. The validation set was also used to compare the system with a clinical expert in predicting time to metastatic death. The rms error was 3.7 years for the system and 4.3 years for the clinical expert for 15 years survival. For <10 years survival, these figures were 2.7 and 4.2, respectively. We concluded that the AI system can match if not better the clinical expert's prediction. There were significant differences with CR and KM analyses when the number of records was small, but it was not known which model is more accurate

  10. Managing elevated intraocular pressure in a patient with optic nerve hypoplasia

    Directory of Open Access Journals (Sweden)

    Karina Marcovitch

    2009-10-01

    Full Text Available Karina Marcovitch, Joseph SowkaNova Southeastern University, College of Optometry, Davie, FL, USABackground: Optic nerve hypoplasia (ONH is a congenital optic disc anomaly, often manifesting with visual deficits.Case: A 51-year-old woman with a history of bilateral amblyopia was referred for glaucoma evaluation due to elevated intraocular pressure. The patient demonstrated the classic nerve head appearance of bilateral ONH with “double ring sign” and indistinguishable cupping. Despite demonstrating functional and structural measurements consistent with glaucomatous optic neuropathy, it was felt that these deficits were more likely longstanding and secondary to ONH. Additionally, in the absence of any amblyogenic factors, it was also concluded that the patient’s bilateral “amblyopia” was the result of ONH. In that the patient presented with a significant and modifiable risk factor for glaucomatous development and pre-existing retinal nerve fiber layer and visual field defects, the patient was treated with topical glaucoma medications. Conclusion: Diagnosing glaucoma in patients with concurrent anomalies is a clinical conundrum. This report provides a review of ONH with emphasis on the common misdiagnosis of amblyopia in these patients as well as presenting a strategy for diagnosing and managing glaucoma in patients with preexisting, confounding conditions. Keywords: optic nerve hypoplasia, glaucoma, visual field loss, scanning laser polarimetry, threshold automated perimetry

  11. Safety and tolerability of tafluprost in treatment of elevated intraocular pressure in open-angle glaucoma and ocular hypertension

    OpenAIRE

    Dorota Pozarowska

    2010-01-01

    Dorota PozarowskaDepartment of Ophthalmology, Medical University, Lublin, PolandAbstract: Glaucoma is one of the most common neuropathies of the optic nerve. An elevated intraocular pressure (IOP) is a well documented risk factor for the development and progression of this disease. Until now, IOP reduction is the only well documented successful method of glaucoma treatment. Among the many hypotensive drugs, prostaglandin analogs are proved to be the most potent antiglaucoma agents, with very ...

  12. Safety and efficacy of travoprost solution for the treatment of elevated intraocular pressure

    Directory of Open Access Journals (Sweden)

    Quaranta L

    2015-04-01

    Full Text Available Luciano Quaranta,1,* Ivano Riva,1,* Andreas Katsanos,2 Irene Floriani,3 Marco Centofanti,4,† Anastasios G P Konstas51Centre for the Study of Glaucoma, University of Brescia, Brescia, Italy; 2Ophthalmology Department, University of Ioannina, Ioannina, Greece; 3Laboratory of Clinical Research, IRCCS, Istituto di Ricerche Farmacologiche Mario Negri, Milan, Italy; 4DSCMT, University of Tor Vergata, Rome, Italy; 5Glaucoma Unit, 1st University Department of Ophthalmology, AHEPA Hospital, Thessaloniki, Greece*These authors contributed equally to this work; †Dr Centofanti passed away on 1 March 2015Abstract: Travoprost is a prostaglandin analogue widely used for reducing intraocular pressure (IOP in patients affected with glaucoma and ocular hypertension. It exerts its ocular hypotensive effect through the prostaglandin FP receptors, located in the ciliary muscle and the trabecular meshwork. Several studies have shown that topical administration of travoprost induces a mean IOP reduction ranging from 25% to 32%, and sustained throughout the 24-hour cycle. When compared with timolol, travoprost is more effective at reducing IOP, while generally no difference has been found in the head-to-head comparison with other prostaglandin analogues. The fixed combination of travoprost and timolol has demonstrated a hypotensive efficacy comparable to the concomitant administration of the two drugs. Recently, a new preservative-free formulation of travoprost 0.004% has been marketed for reducing tolerability-related problems in subjects affected with ocular surface disease. Low rates of topical and systemic adverse reactions, strong ocular hypotensive efficacy, and once-a-day dosing make travoprost a first-line treatment for patients affected with elevated IOP.Keywords: prostaglandin analogue, glaucoma, ocular hypertension

  13. Genetic context determines susceptibility to intraocular pressure elevation in a mouse pigmentary glaucoma

    Directory of Open Access Journals (Sweden)

    Cosma Ioan M

    2006-07-01

    Full Text Available Abstract Background DBA/2J (D2 mice develop an age-related form of glaucoma. Their eyes progressively develop iris pigment dispersion and iris atrophy followed by increased intraocular pressure (IOP and glaucomatous optic nerve damage. Mutant alleles of the Gpnmb and Tyrp1 genes are necessary for the iris disease, but it is unknown whether alleles of other D2 gene(s are necessary for the distinct later stages of disease. We initiated a study of congenic strains to further define the genetic requirements and disease mechanisms of the D2 glaucoma. Results To further understand D2 glaucoma, we created congenic strains of mice on the C57BL/6J (B6 genetic background. B6 double-congenic mice carrying D2-derived Gpnmb and Tyrp1 mutations develop a D2-like iris disease. B6 single-congenics with only the Gpnmb and Tyrp1 mutations develop milder forms of iris disease. Genetic epistasis experiments introducing a B6 tyrosinase mutation into the congenic strains demonstrated that both the single and double-congenic iris diseases are rescued by interruption of melanin synthesis. Importantly, our experiments analyzing mice at ages up to 27 months indicate that the B6 double-congenic mice are much less prone to IOP elevation and glaucoma than are D2 mice. Conclusion As demonstrated here, the Gpnmb and Tyrp1 iris phenotypes are both individually dependent on tyrosinase function. These results support involvement of abnormal melanosomal events in the diseases caused by each gene. In the context of the inbred D2 mouse strain, the glaucoma phenotype is clearly influenced by more genes than just Gpnmb and Tyrp1. Despite the outward similarity of pigment-dispersing iris disease between D2 and the B6 double-congenic mice, the congenic mice are much less susceptible to developing high IOP and glaucoma. These new congenic strains provide a valuable new resource for further studying the genetic and mechanistic complexity of this form of glaucoma.

  14. The Management of a Patient with Elevated Intraocular Pressure Resistant to Medical Treatment: Anterior Chamber Irrigation

    Directory of Open Access Journals (Sweden)

    Abdullah Beyoğlu

    2014-10-01

    Full Text Available A 7-year-old male patient was medically treated in another center for hyphema which occurred after blunt trauma to his right eye. He was admitted to our clinic when his visual acuity decreased after being discharged. Biomicroscopic examination revealed total hyphema. Intraocular pressure (IOP was 48 mm Hg in the right eye with Goldmann applanation tonometry. Since IOP could not be managed by medical therapy and there was no regression in hyphema, anterior chamber was irrigated. As in our case, it should not be forgotten that re-hemorrhage may occur in the first week of hyphema during childhood. Moreover, surgical treatment should be considered when hemorrhage does not regress with medical treatment, increased IOP persists, and when there is a risk of corneal endothelial staining (corneal blood staining. (Turk J Ophthalmol 2014; 44: 400-2

  15. Aspherical Lens Design Using Genetic Algorithm for Reducing Aberrations in Multifocal Artificial Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Chih-Ta Yen

    2015-09-01

    Full Text Available A complex intraocular lens (IOL design involving numerous uncertain variables is proposed. We integrated a genetic algorithm (GA with the commercial optical design software of (CODE V to design a multifocal IOL for the human eye. We mainly used an aspherical lens in the initial state to the crystalline type; therefore, we used the internal human eye model in the software. The proposed optimized algorithm employs a GA method for optimally simulating the focusing function of the human eye; in this method, the thickness and curvature of the anterior lens and the posterior part of the IOL were varied. A comparison of the proposed GA-designed IOLs and those designed using a CODE V built-in optimal algorithm for 550 degrees myopia and 175 degrees astigmatism conditions of the human eye for pupil size 6 mm showed that the proposed IOL design improved the spot size of root mean square (RMS, tangential coma (TCO and modulation transfer function (MTF at a spatial frequency of 30 with a pupil size of 6 mm by approximately 17%, 43% and 35%, respectively. However, the worst performance of spherical aberration (SA was lower than 46%, because the optical design involves a tradeoff between all aberrations. Compared with the traditional CODE V built-in optimal scheme, the proposed IOL design can efficiently improve the critical parameters, namely TCO, RMS, and MTF.

  16. Artificial neural networks application in duplex/triplex elevator group control system:

    OpenAIRE

    Imrak, C. Erdem

    2008-01-01

    Artificial neural networks can offer the better solution to the passenger call distribution problem when compared to the conventional elevator control systems. Therefore, the application of neural networks in elevator group control system is discussed. The significance of introducing artificial neural networks is presented. Elevator group control systems with neural networks can predict the next stopping floors to stop by considering what has been learnt by processing the changes in passenger...

  17. 超声乳化+人工晶体植入术及整体护理应用%Phacoemulsification + artificial intraocular lens implantation and application of holistic nursing

    Institute of Scientific and Technical Information of China (English)

    薛佩琴

    2011-01-01

    Objective To implement advanced phacoemulsification + artificial intraocular lens implantation, improving the cure rate of cataract surgery. Methods Holistic nursing was implemented in the preoperative, intraoperative and postoperative process, so as to organically integrate phacoemulsification and artificial intraocular lens implantation in cataract surgery. The surgery procedures and its relevant nursing have been made specific and operational, fully embodying the principle of patient - centered and holistic nursing which highlighted the principle of "putting people first". Results The application of holistic nursing effectively alleviated the fear and anxiety of patients. After surgery, visual recovery rate of 893 patients was above 97% . Conclusion The integration of phacoemulsification + artificial intraocular lens implantation in cataract surgery and holistic nursing can have better effects, higher cure ate and increased satisfaction of medical staff. It is worthy of wider clinical application in eye surgery.%目的 开展先进的超声乳化+人工人工晶体植入术,提高白内障手术的治愈率.方法 运用整体护理于手术的术前、术中、术后全过程,使白内障超声乳化+人工晶体植入术与整体护理有机结合,将手术及护理范围扩展并细化,充分体现一切“以患者为中心”,处处体现以人为本的整体护理.结果 整体护理的运用有效地缓解了患者的恐惧紧张心理,893例患者术后视力恢复良好率达97%以上.结论 白内障超声乳化+人工晶体植入术与整体护理的运用,手术效果好,治愈率高,患者欢迎,医护人员满意,是眼科手术临床运用的好方法.

  18. Changes in the retrobulbar arterial circulation after decrease of the elevated intraocular pressure in men and women with primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2013-01-01

    Full Text Available Introduction. An altered perfusion of the optic nerve head has been proposed as a pathogenic factor of glaucoma. Objective. The aim of this study was to evaluate the changes of the hemodynamic parameters in the retrobulbar arterial circulation after decrease of the elevated intraocular pressure (IOP in women and men with primary open angle glaucoma. Methods. The study included 60 patients (33 males and 27 females older than 50 years, with diagnosed and treated primary open angle glaucoma (77 eyes of 39 patients had increased IOP, >25 mm Hg. They were examined at the Clinic of Eye Diseases (complete ophthalmologic exam and Clinic of Neurology, Clinical Center of Serbia, Belgrade, from December 2009 to December 2010. Imaging of hemodynamic parameters of three retrobulbar arterial vessels: ophthalmic, central retinal and posterior ciliary arteries with color Doppler was performed. Results. Among women, hemodynamic arterial parameter of the peak-systolic velocity was increased in the central retinal artery and decreased in the ophthalmic artery and posterior ciliary arteries; end- diastolic velocity was increased in all three retrobulbar vascular levels; Pourcelot resistivity index was increased, but pulsatility index was decreased in all three vessels. Among men, peak-systolic velocity, end-diastolic velocity and pulsatility index were decreased in all three vessels; resistivity index was increased in the ophthalmic artery, but decreased in the central retinal artery and posterior ciliary arteries. There was a significant change of the ophthalmic artery pulsatility index in women, and the end-diastolic velocity of the ophthalmic artery in men. Conclusion. There was a difference of the retrobulbar arterial circulation between women and men with primary open angle glaucoma after decrease of the elevated intraocular pressure. The role of vascular factors in the supply of the optic disc neuroretinal rim is important.

  19. Relationship between the magnitude of intraocular pressure during an episode of acute elevation and retinal damage four weeks later in rats.

    Directory of Open Access Journals (Sweden)

    Bang V Bui

    Full Text Available PURPOSE: To determine relationship between the magnitude of intraocular pressure (IOP during a fixed-duration episode of acute elevation and the loss of retinal function and structure 4 weeks later in rats. METHODS: Unilateral elevation of IOP (105 minutes was achieved manometrically in adult Brown Norway rats (9 groups; n = 4 to 8 each, 10-100 mm Hg and sham control. Full-field ERGs were recorded simultaneously from treated and control eyes 4 weeks after IOP elevation. Scotopic ERG stimuli were white flashes (-6.04 to 2.72 log cd.s.m(-2. Photopic ERGs were recorded (1.22 to 2.72 log cd.s.m(-2 after 15 min of light adaptation (150 cd/m(2. Relative amplitude (treated/control, % of ERG components versus IOP was described with a cummulative normal function. Retinal ganglion cell (RGC layer density was determined post mortem by histology. RESULTS: All ERG components failed to recover completely normal amplitudes by 4 weeks after the insult if IOP was 70 mmHg or greater during the episode. There was no ERG recovery at all if IOP was 100 mmHg. Outer retinal (photoreceptor function demonstrated the least sensitivity to prior acute IOP elevation. ERG components reflecting inner retinal function were correlated with post mortem RGC layer density. CONCLUSIONS: Retinal function recovers after IOP normalization, such that it requires a level of acute IOP elevation approximately 10 mmHg higher to cause a pattern of permanent dysfunction similar to that observed during the acute event. There is a 'threshold' for permanent retinal functional loss in the rat at an IOP between 60 and 70 mmHg if sustained for 105 minutes or more.

  20. A Case of Sustained Intraocular Pressure Elevation after Multiple Intravitreal Injection of Ranibizumab and Aflibercept for Neovascular Age-Related Macular Degeneration

    Science.gov (United States)

    Matsubara, Hisashi; Miyata, Ryohei; Kobayashi, Maki; Tsukitome, Hideyuki; Ikesugi, Kengo; Kondo, Mineo

    2016-01-01

    Intravitreal injections of anti-vascular endothelial growth factor (VEGF) agents are widely used to treat neovascular age-related macular degeneration (nAMD). Although these treatments are effective, multiple injections have recently been recommended to ensure that there is a good long-term prognosis. However, sustained intraocular pressure (IOP) elevations have been reported to develop after multiple injections of anti-VEGF agents. We present our findings of a case of uncontrolled and persistent IOP elevation after switching from intravitreal ranibizumab injections to intravitreal aflibercept injections. A 74-year-old Japanese man without a history of glaucoma underwent 22 ranibizumab injections for nAMD and suddenly developed an elevated IOP after the 22nd injection. Although the subsequent medical treatment led to normalization of his IOP, the subretinal fluid under the central fovea remained even after the 25th injection of ranibizumab. Thus, ranibizumab treatment was switched to bimonthly intravitreal aflibercept injections in conjunction with glaucoma medications. His IOP recovered to within the normal range; however, after the 11th aflibercept injection, there was a sudden elevation of his IOP in spite of the continued glaucoma medications. Due to this sustained IOP elevation, his aflibercept injections were suspended for 16 weeks. Because his IOP could not be normalized by a full glaucoma medication regimen, the patient underwent trabeculotomy, which resulted in a lowering of the IOP to normal levels. We conclude that patients who receive serial intravitreal injections of anti-VEGF agents need to be closely monitored because severe and sustained ocular hypertension can develop.

  1. Roles of PI3K and JAK pathways in viability of retinal ganglion cells after acute elevation of intraocular pressure in rats with different autoimmune backgrounds

    Directory of Open Access Journals (Sweden)

    Wang Ningli

    2008-08-01

    Full Text Available Abstract Background We recently showed that whereas inhibition of PI3K/akt or JAK/STAT pathway promoted retinal ganglion cell (RGC survival after optic nerve (ON injury in Fischer 344 (F344 rats, the same inhibition resulted in aggravated RGC loss after acute intraocular pressure (IOP elevation in Sprague Dawley (SPD rats. In addition, the responses of macrophages to ON injury and acute IOP elevation were different between F344 and Lewis rats, i.e., different autoimmune profiles. Using an acute IOP elevation paradigm in this study, we investigated 1 whether autoimmune background influences PI3K/akt and JAK/STAT functions by examining the effect of PI3K/akt and JAK/STAT pathway inhibition on RGC survival in F344 and Lewis rats, and 2 whether differential actions of macrophages occur in PI3K/akt and JAK/STAT pathways-dependent modulation of RGC survival. IOP elevation was performed at 110 mmHg for 2 hours. PI3K/akt and JAK/STAT pathway inhibitors were applied intravitreally to block their respective pathway signaling transduction. Because macrophage invasion was seen in the eye after the pathway inhibition, to examine the role of these pathways independent of macrophages, macrophages in the retina were removed by intravitreal application of clodronate liposomes. Viable RGCs were retrogradely labelled by FluoroGold 40 hours before animal sacrifice. Results Similar to what was previously observed, significantly more RGCs were lost in Lewis than F344 rats 3 weeks after acute IOP elevation. As in SPD rats, inhibition of the PI3K/akt or JAK/STAT pathway increased the loss of RGCs in both F344 and Lewis rats. Removal of macrophages in the eye by clodronate liposomes reduced RGC loss due to pathway inhibition in both strains. Conclusion This study demonstrates that following acute IOP elevation 1 PI3K/akt and JAK/STAT pathways mediate RGC survival in both F344 and Lewis rats, 2 autoimmune responses do not influence the functions of these two pathways

  2. 硅油注入后高眼压的治疗策略%Therapy for elevated intraocular pressure after silicone oil tamponade

    Institute of Scientific and Technical Information of China (English)

    张歆; 梁四妥; 杨艳; 赵华; 徐深

    2012-01-01

    Objective To analyze intraocular pressure (IOP) after silicone oil tamponade for one month.Methods This is a retrospective study.There were 46 cases (46 eyes) from 2004 to 2011 registered in our hospital who accepted vitrectomy and silicone oil tamponade,after one month later,who had elevated IOP.We compared the rate of elevated IOP between two types of silicon oil tamponade for one month,as well as the treatment for elevated IOP.x2 test was used to analyze the results.Result The time for light silicon oil removal was three months ( the rate is 68.8% ) after the operation,and after the second surgery the IOP could be normal.And the time for heavy silicon oil removal was two months (the rate is 64.3% ),then the IOP could be normal.The two results had no statistical differences.But the rate of glaucoma surgery after heavy silicone oil tamponade was higher than that of light silicone oil tamponade.And this result had statistical difference.Conclusion The rate of elevated IOP after light or heavy silicone oil tamponade after one month was the same.The rate of glaucoma surgery after heavy silicone oil tamponade was higher than that of light silicone oil tamponade.%目的 回顾性分析轻重硅油注入术后1个月高眼压的发生及其治疗策略.方法 玻切+轻/重硅油注入术后1个月发生高眼压共46例(46眼).对两种硅油注入术后1个月高眼压的发生率进行分析对比,且对高眼压的处理方式进行对比.结果用x2检验进行分析.结果 轻硅油注入术后取油的时机一般在3个月(68.8%)左右,取出后高眼压可以降至正常范围;重硅油在2个月左右取油(64.3%),取出后高眼压可以降至正常范围.二者没有统计学差异.但重硅油注入术后因高眼压行抗青光眼手术的比例较轻硅油者高,差异有统计学意义.结论 轻重硅油注入术后1个月高眼压的发生率没有统计学差异,但重硅油引起的高眼压最终行抗青光眼手术的比例较轻硅油者高.

  3. 优视胶囊对急性高眼压家兔眼压及神经节细胞的影响%Effects of Youshi capsule on the intraocular pressure(IOP) and retinal ganglion cells (RGC) of rabbits under artificial acute intraocular hypertension

    Institute of Scientific and Technical Information of China (English)

    张宗端; 段俊国

    2001-01-01

    目的:观察优视胶囊对急性高眼压兔眼压的影响及对视网膜视神经的保护作用。方法:采用自行设计的上巩膜静脉结扎法建立18只兔眼急性高眼压动物模型,于造模前1周至造模后3天共10天内给予具活血化瘀、开窍明目功效的优视胶囊灌胃,18只造模眼随机分为模型组、低剂量组和高剂量组,每组6眼,与18只正常眼进行对照。实验过程中测量眼压并行视网膜神经节细胞计数。结果:①造模后即可获得平均眼压高于6.83kPa并能持续3天以上的高眼压动物模型,优视胶囊高、低剂量组表现出轻微的降眼压作用。②持续性的高眼压可造成视网膜神经节细胞减少,但高、低剂量组经优视胶囊治疗后高眼压模型眼神经节细胞数高于模型组,提示优视胶囊具有保护或改善急性高眼压后兔眼视网膜神经节细胞的作用。结论:优视胶囊对急性高眼压兔眼视网膜视神经具有保护的作用。%Objective:To observe the effects of Youshi capsule on the intraocular pressure(IOP) and retinal ganglion cells(RGC) of rabbits under artificial acute intraocular hypertension.Methods:We used episcleral veins ligation on rabbit to establish an acute intraocular hypertension animal model devised by ourselves. Between one week before and 3 days after the models were induced, Youshi capsule was irrigated into the stomachs, having the function of promoting blood circulation and removing blood stasis,opening porus and improving vision. 18 model-established eyes were randomly divided into model group, high and low dosage group(6 eyes each group) and compared with other 18 normal eyes. Then examined IOP and counted RGC.Results:①Acute intraocular hypertension animal model was produced just after model was established and its average IOP above 6.83kPa could maintain 3 days. High and low dosage Youshi capsule showed slight effect on the reduction of IOP in intraocluar

  4. Comparison of the efficacy and safety of 2% dorzolamide and 0.5% betaxolol in the treatment of elevated intraocular pressure. Dorzolamide Comparison Study Group.

    Science.gov (United States)

    Rusk, C; Sharpe, E; Laurence, J; Polis, A; Adamsons, I

    1998-01-01

    A multicenter, parallel-design, randomized, double-masked study was conducted to compare the efficacy and safety of 2% dorzolamide with those of 0.5% betaxolol in the treatment of elevated intraocular pressure (i.o.p). A total of 311 adults with ocular hypertension or open-angle glaucoma were randomly allocated to receive either 2% dorzolamide administered topically TID or 0.5% betaxolol administered topically BID plus placebo administered topically QD for 12 weeks. After the washout of previous ocular hypotensive drugs, patients with IOP > or = 23 mm Hg in at least one eye at 10 AM or 4 PM on study day 1 were randomly allocated to receive one of the study treatments. Throughout the study, IOP was measured 2 and 8 hours after instillation of study medication for the morning peak effect (hour 2) and afternoon trough effect (hour 8). After 12 weeks of therapy, the mean change in IOP was not significantly different between the dorzolamide and betaxolol treatment groups at hour 8 (-3.6 mm Hg in both groups) or hour 2 (-5.4 vs -5.3 mm Hg, respectively). The differences between treatments (and 95% CIs associated with these differences) in mean IOP changes from baseline were 0.02 mm Hg (-0.870 to 0.901) for hour 8 and -0.14 mm Hg (-0.959 to 0.685) for hour 2. The ocular adverse experience (AE) most frequently reported by patients was ocular burning and/or stinging, and the most frequently reported nonocular AEs were taste perversion, upper respiratory infection, and headache. Only the incidence of taste perversion was significantly different between treatment groups (14.6% for the dorzolamide group and 0.0% for the betaxolol group). Two percent of patients in each treatment group discontinued the study due to AEs. This study confirmed the similar IOP-lowering effect of 2% dorzolamide and 0.5% betaxolol. Both treatments were generally well tolerated, and their safety profiles were similar. PMID:9663361

  5. Role of fixed-combination brinzolamide 1%/timolol 0.5% in the treatment of elevated intraocular pressure in open-angle glaucoma and ocular hypertension

    OpenAIRE

    Beckers, Henny

    2009-01-01

    Henny JM Beckers, Jan SAG Schouten, Carroll AB WebersUniversity Eye Clinic, Maastricht, The NetherlandsAbstract: Brinzolamide 1%/timolol 0.5% is a new fixed-combination for the treatment of open-angle glaucoma or ocular hypertension. Brinzolamide/timolol has a favorable safety profile, with an incidence of ocular burning and stinging <5%. Published data show that brinzolamide 1%/timolol 0.5% and dorzolamide 2%/timolol 0.5% have similar efficacies for lowering intraocular pressure (IOP)...

  6. Role of prostaglandins and specific place in therapy of bimatoprost in the treatment of elevated intraocular pressure and ocular hypertension: A closer look at the agonist properties of bimatoprost and the prostamides

    Directory of Open Access Journals (Sweden)

    Scott D Smid

    2009-11-01

    Full Text Available Scott D SmidDiscipline of Pharmacology, School of Medical Sciences, Faculty of Health Sciences, University of Adelaide, Adelaide, SA, AustraliaAbstract: Bimatoprost is the only representative of a novel class of prostaglandin ethanolamide (prostamide compounds used therapeutically as an efficacious treatment for glaucoma. The pathways through which bimatoprost works to improve uveoscleral outflow to relieve elevated intraocular pressure are similar to those of the conventional prostaglandins used in glaucoma therapy, with some evidence of a preferential action at the trabecular meshwork. The pharmacology of bimatoprost is however, unclear. Pharmacological evidence supports a specific and distinct receptor-mediated agonist activity of bimatoprost at ‘prostamide’ receptors, which is selective to the prostamides as a class. However, other studies have reported either activity of bimatoprost at additional prostanoid and nonprostanoid receptors, or a conversion of bimatoprost to metabolites with agonist activity at prostaglandin FP receptors in the human eye. The formation of endogenous prostamides has been demonstrated in vivo, by a novel pathway involving the cyclooxygenase-2-mediated conversion of endogenous cannabinoid (endocannabinoid substrates. Irrespective of the pharmacology of bimatoprost and the prostamides in general, further studies are needed to determine the biological role and biochemical pathology of prostamides in the human eye, particularly in glaucoma. Such studies may improve our understanding of uveoscleral flow and may offer new treatments for controlling intraocular pressure.Keywords: bimatoprost, endocannabinoid, glaucoma, prostamides, trabecular meshwork

  7. Role of fixed-combination brinzolamide 1%/timolol 0.5% in the treatment of elevated intraocular pressure in open-angle glaucoma and ocular hypertension

    Directory of Open Access Journals (Sweden)

    Henny JM Beckers

    2009-10-01

    Full Text Available Henny JM Beckers, Jan SAG Schouten, Carroll AB WebersUniversity Eye Clinic, Maastricht, The NetherlandsAbstract: Brinzolamide 1%/timolol 0.5% is a new fixed-combination for the treatment of open-angle glaucoma or ocular hypertension. Brinzolamide/timolol has a favorable safety profile, with an incidence of ocular burning and stinging <5%. Published data show that brinzolamide 1%/timolol 0.5% and dorzolamide 2%/timolol 0.5% have similar efficacies for lowering intraocular pressure (IOP. There is some evidence that brinzolamide/timolol may be more comfortable. Although patients receiving brinzolamide/timolol may experience more blurred vision on instillation, some data show a preference for brinzolamide/timolol over dorzolamide/timolol. Although available data to assess the role of brinzolamide/timolol in daily clinical practice are still limited, these first results suggest the agent to be a reasonable alternative for patients who do not reach target IOP with monotherapy.

  8. 玻璃体切除硅油填充术后高眼压临床分析%Clinical analysis of intraocular pressure(IOP) elevation after vitrectomy and silicon oil tamponade

    Institute of Scientific and Technical Information of China (English)

    黄庆; 张军军

    2012-01-01

    Objective To investigate the causes and measurements of intraocular pressure (IOP) elevation after vitrectomy. Methods To retrospectively analyze clinical data of thirty-one eyes out of one hundred and sixty patients (one hundred and seventy-eight eyes) which had IOP elevation in early period after vitrectomy from January,2010 to December, 2010. Results The causes of postoperative IOP elevation ate uveitic inflammation (eighteen eyes, 58. 1% ), aphakia (four eyes, 12.9%), steroids ((our eyes, 12.9%), silicon oil tamponade excess (three eyes, 9.7%) and endoph-thalmitis (two eyes, 6.5%). After various treatments such as IOP-lowering medication, stop using of steroids, taken-out part of silicon oil, paracentesis of anterior chamber and change to hign-grade antibiotics, the IOP of all eyes returned to normal. Conclusion The incidence of IOP elevation after vitrectomy is 17.4% and uveitic inflammation is the common cause. Timely prevention and proper measurement can reduce visual damage.%目的 探讨玻璃体切除硅油填充术后高眼压的原因及处理.方法 回顾性分析2010年1月到2010年12月本院160例(178只眼)玻璃体切除硅油填充术后早期发生高眼压31例(31只眼)的临床资料.结果 术后高眼压发生原因如下:葡萄膜炎症反应(18只眼,58.1%)、无晶状体眼(4只眼,12.9%)、激素引发(4只眼,129%)、硅油填充过量(3只眼,9.7%)、眼内炎(2只眼,6.5%).给予降眼压药物、停用激素类药物、硅油部分取出、前房穿刺或换用敏感抗生素等治疗后,眼压均降至正常.结论 玻璃体切除硅油填充术后高眼压在本研究的发生率为17.4%,术后葡萄膜炎症反应为常见原因,及时的预防和处理能减少视功能的损害.

  9. Bilateral Primary Intraocular Lymphoma

    Directory of Open Access Journals (Sweden)

    Mehrdad Karimi

    2011-01-01

    Full Text Available Purpose: To report a case of bilateral primary intraocular lymphoma. Case report: A 33-year-old man presented with bilateral blurred vision since two years ago. Examination revealed large keratic precipitates, anterior chamber reaction, posterior subcapsular cataracts, and vitreous infiltration. After a short trial of topical and periocular steroids, diagnostic 25-gauge pars plana vitrectomy was performed and cytologic evaluation of the aspirate confirmed a diagnosis of intraocular lymphoma. The patient was subsequently managed with intravitreal methotrexate in both eyes and responded favorably. Central nervous system workup for lymphoma was negative. Conclusion: Primary intraocular lymphoma should be considered in young adults suffering from chronic recalcitrant panuveitis.

  10. Bilateral Primary Intraocular Lymphoma

    OpenAIRE

    Mehrdad Karimi; Masoud Soheilian; Mozhgan Rezaei Kanavi

    2011-01-01

    Purpose: To report a case of bilateral primary intraocular lymphoma. Case report: A 33-year-old man presented with bilateral blurred vision since two years ago. Examination revealed large keratic precipitates, anterior chamber reaction, posterior subcapsular cataracts, and vitreous infiltration. After a short trial of topical and periocular steroids, diagnostic 25-gauge pars plana vitrectomy was performed and cytologic evaluation of the aspirate confirmed a diagnosis of intraocular lympho...

  11. Bilateral intraocular dirofilariasis

    Directory of Open Access Journals (Sweden)

    Viney Gupta

    2014-01-01

    Full Text Available Ocular dirofilariasis mostly presents as a subconjunctival or eyelid lesion. [1] Intraocular dirofilarial infestation is rare. [2],[3] We report a case of a young woman who was accidentally detected to have a live motile worm in the anterior segment in one eye and a cystic lesion on the optic disc in the other eye. To our knowledge, bilateral intraocular dirofilariasis has never been reported.

  12. Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique.

    Science.gov (United States)

    Kelkar, Aditya; Shah, Rachana; Kelkar, Jai; Kelkar, Shreekant; Arora, Ekta

    2015-01-01

    Sutureless, glueless, scleral fixation of an intraocular lens is a known technique of fixing a lens in the scleral pockets. However, this technique is applied to single-piece and toric lenses instead of 3-piece lenses, allowing the advantage of the use of premium lenses in patients with poor capsular support. Favourable results without complications of pigment dispersion, iris transillumination defects, dysphotopsia, elevated intraocular pressure, intraocular hemorrhage and cystoid macular edema with a well-centered, stable intraocular lens have been observed in the 3-month postoperative period in both cases.

  13. Opaque intraocular lens implantation

    OpenAIRE

    Yusuf IH; Patel CK

    2013-01-01

    Imran H Yusuf, CK Patel The Oxford Eye Hospital, West Wing, John Radcliffe Hospital, Headley Way, Headington, Oxford, United KingdomWe read with great interest the recent article by Lee et al,1 who described their clinical experience with three patients who underwent primary implantation of Morcher (Stuttgart, Germany) occlusive intraocular lenses (IOLs) across a variety of neuro-ophthalmic indications. We hope to offer some further insight into these clinical observations in the context of o...

  14. claw intraocular lens

    OpenAIRE

    Gonnermann, Johannes

    2015-01-01

    There is a wide range of alternative fixation techniques of intraocular lenses in the absence of adequate capsular support, such as angle- or iris-supported anterior chamber lenses and intra- / transsclerally-fixated (suture, fibrin glue, etc.) and iris-supported posterior chamber lenses. All procedures have different advantages and disadvantages depending on the anatomical situation and integrity of the capsular bag complex and the neighboring structures such as the iris, sclera and corneal ...

  15. Phakic Intraocular lens- a review

    OpenAIRE

    Cruz, Francisco Miguel

    2015-01-01

    Introduction: Intraocular refractive procedures with the implantation of a Phakic Intraocular lens have become a safe efficient and predictable alternative for treating high ametropias when the use of corneal photoablative procedures is not possible. The implantation of Phakic intraocular lens preservs the accomodative function,is a reversable refractive procedure, with minimal induction of higher order aberrations compaed with corneal photoablative procedures. Methods: An analytical review o...

  16. How to measure intraocular pressure: applanation tonometry

    Directory of Open Access Journals (Sweden)

    Nick Astbury

    2012-01-01

    Full Text Available Unless there is a contraindication (e.g. trauma or corneal ulcer, all adults attending an eye unit should have their intraocular pressure (IOP measured. Many people with glaucoma have no symptoms and do not know they have the condition. All children who have had cataract surgery should also have their IOP measured at every follow-up visit, if possible. Finding glaucoma early allows treatment to be given which will preserve sight. Although elevated IOP is not the only sign of glaucoma, measuring it is simple and quick to do. Applanation tonometry, using a Goldmann tonometer at a slit lamp, is the preferred method (the ‘gold standard’.

  17. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  18. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  19. Professor Peter Choyce: an early pioneer of intraocular lenses and corneal/refractive surgery.

    Science.gov (United States)

    Pandey, Suresh K; Apple, David J

    2005-06-01

    Professor Peter Choyce, FRCS, DOMS, MS, was one of the pioneers of intraocular lens implant surgery. He developed an interest in artificial lens implantation following cataract surgery, a procedure that was widely criticized by the ophthalmic establishment in the UK, Europe, North America and other countries. Owing to the opposition to the intraocular lenses, Peter Choyce together with Sir Harold Ridley co-founded the International Intraocular Implant Club in 1966, which was responsible for the gradual acceptance of artificial lens implantation. Peter Choyce developed several models of intraocular lens, but did not patent the majority of them. The Choyce Mark IX, manufactured by Rayner Intraocular Lenses, became the first US Food and Drug Administration-approved intraocular lens in 1981. A review of Peter Choyce's record confirms a significant number of original innovations in the field of anterior segment surgery, including many procedures taken for granted today, but not associated with his name. These include early work on both kerato- and intraocular lens-refractive procedures, keratoprosthesis, pioneering paediatric implant procedures and others. Unfortunately his tenacious adherence to anterior chamber lens technology, while in general clinically sound, caused many to question his influence and hence he remained poorly understood even until after his death. He passed away on 8 August 2001 after a long fight with colon cancer. In this article, we provide evidence and elaborate Peter Choyce's accomplishments, which places him as one of the most innovative ophthalmologist in his surgical field in the twentieth century.

  20. Intraocular coenurosis: a case report.

    OpenAIRE

    Ibechukwu, B. I.; Onwukeme, K. E.

    1991-01-01

    A case of intraocular coenurosis was clinically diagnosed and treated with praziquantel. The drug destroyed the coenurus, but vision was lost through toxic endophthalmitis and retinal detachment. There were no systemic side effects.

  1. Mechanisms for vasopressin effects on intraocular pressure in anesthetized rats

    Science.gov (United States)

    Balaban, C. D.; Palm, D. E.; Shikher, V.; Searles, R. V.; Keil, L. C.; Severs, W. B.

    1997-01-01

    Continuous intracameral infusions of a balanced salt solution (0.175 microliter min-1) have been reported to raise intraocular pressure (IOP) in anesthetized rats. Palm et al. (1995) previously reported that this effect was attenuated significantly by inclusion of arginine-vasopressin (AVP, 10 ng 0.175 microliter-1) in the infusate. This study used experimental and computer simulation methods to investigate factors underlying these changes in IOP. First, constant intracameral infusions of artificial cerebrospinal fluid (aCSF) at different fixed rates (0.049-0.35 microliter min-1) were used to estimate the outflow resistance. Secondly, IOP responses were measured during an 2 hr intracameral infusion of either aCSF or AVP that was the sum of a small constant component (0.05 microliter min-1) and a larger periodic component (0.25 microliter min-1, cycling for 4 min on, then 4 min off); the mean infusion rate was 0.175 microliter min-1. As shown previously for 0.175 microliter min-1 constant infusions, the periodic aCSF infusion induced a significant rise in IOP that was attenuated by AVP administration. Complex demodulation analysis and the estimated gain parameter of a second order transfer function fit to the periodic responses indicated that outflow resistance increased significantly during the infusions in both aCSF and AVP groups, but that the indices of resistance did not differ significantly between aCSF and AVP infused eyes. This finding implies that changes in outflow resistance do not explain the difference in IOP responses to intracameral aCSF and AVP. The two responses differed significantly, though, in damping factors, such that the aCSF responses were considerably more underdamped than the AVP responses. It is hypothesized that aCSF-induced increase in IOP reflects both (1) a small component reflecting increased outflow resistance and (2) a larger non-resistive component. Since the non-resistive component is insensitive to pretreatment with acetazolamide

  2. Short-term intraocular pressure changes after intravitreal injection of bevacizumab in diabetic retinopathy patients

    OpenAIRE

    Farhood, Qasim

    2014-01-01

    Qasim Kadhim Farhood,1 Sinan Mohammad Twfeeq21College of Medicine, Babylon University, Babylon; 2Al-Jumhori teaching hospital, Mosul, IraqBackground: This study examined the changes in short-term intraocular pressure (IOP) in a prospective series of patients undergoing intravitreal bevacizumab injection. The aim was to evaluate the frequency and predictive factors related to intraocular pressure (IOP) elevation in patients receiving intravitreal bevacizumab.Patients and methods: This study in...

  3. Do elevations in temperature, CO2, and nutrient availability modify belowground carbon gain and root morphology in artificially defoliated silver birch seedlings?

    Science.gov (United States)

    Huttunen, Liisa; Saravesi, Karita; Markkola, Annamari; Niemelä, Pekka

    2013-09-01

    Climate warming increases the risk of insect defoliation in boreal forests. Losses in photosynthetically active surfaces cause reduction in net primary productivity and often compromise carbon reserves of trees. The concurrent effects of climate change and removal of foliage on root growth responses and carbohydrate dynamics are poorly understood, especially in tree seedlings. We investigated if exposures to different combinations of elevated temperature, CO2, and nutrient availability modify belowground carbon gain and root morphology in artificially defoliated 1-year-old silver birches (Betula pendula). We quantified nonstructural carbohydrates (insoluble starch as a storage compound; soluble sucrose, fructose, and glucose) singly and in combination in fine roots of plants under winter dormancy. Also the total mass, fine root proportion, water content, and length of roots were defined. We hypothesized that the measured properties are lower in defoliated birch seedlings that grow with ample resources than with scarce resources. On average, fertilization markedly decreased both the proportion and the carbohydrate concentrations of fine roots in all seedlings, whereas the effect of fertilization on root water content and dry mass was the opposite. However, defoliation mitigated the effect of fertilization on the root water content, as well as on the proportion of fine roots and their carbohydrate concentrations by reversing the outcomes. Elevation in temperature decreased and elevation in CO2 increased the absolute contents of total nonstructural carbohydrates, whereas fertilization alleviated both these effects. Also the root length and mass increased by CO2 elevation. This confirms that surplus carbon in birch tissues is used as a substrate for storage compounds and for cell wall synthesis. To conclude, our results indicate that some, but not all elements of climate change alter belowground carbon gain and root morphology in defoliated silver birch seedlings.

  4. Increased Intraocular Pressure after Extensive Conjunctival Removal: A Case Report

    OpenAIRE

    Lee, Young Rok; Na, Jung Hwa; Kim, Jae Yong; Sung, Kyung Rim

    2013-01-01

    A 50-year-old woman, who had undergone extensive removal of conjunctiva on the right eye for cosmetic purposes at a local clinic 8 months prior to presentation, was referred for uncontrolled intraocular pressure (IOP) elevation (up to 38 mmHg) despite maximal medical treatment. The superior and inferior conjunctival and episcleral vessels were severely engorged and the nasal and temporal bulbar conjunctival areas were covered with an avascular epithelium. Gonioscopic examination revealed an o...

  5. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials...

  6. Foldable micro coils for a transponder system measuring intraocular pressure

    Energy Technology Data Exchange (ETDEWEB)

    Ullerich, S.; Schnakenberg, U. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1; Mokwa, W. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1]|[Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany); Boegel, G. vom [Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany)

    2001-07-01

    A foldable transponder system consisting of a chip and a micro coil for measuring intraocular pressure continuously is presented. The system will be integrated in the haptic of a soft artificial intraocular lens. Calculations of planar micro coils with 6 mm and 10.3 mm in diameter show the limits for planar coils with an outer diameter of 6 mm. For the realisation of the transponder system a 20 {mu}m thick coil with an outer diameter of 10.3 mm, an inner diameter of 7.7 mm, 16 turns and a gap of 20 {mu}m between the windings was selected. Measurements show a good agreement between calculated and measured values. Wireless pressure measurements were carried out showing a linear behaviour of the output signal with respect to the applied pressure. (orig.)

  7. Study on Titanium Nitride Film Modified for Intraocular Lens

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective:To study the characteristics of the intraocular lens using ion beam sputtering depositing titanium nitride thin film on the intraocular lens(IOLs).Methods:To deposite titanium nitride thin film on the top of intraocular lens by ion beam sputtering depositing.We analyzed the surface morphology of intraocular lens through SEM and AFM.We detected intraocular lens resolution through the measurement of intraocular lens.Biocompatibility of intraocular lens is preliminary evaluated in this test.Results:T...

  8. [Intraocular Inflammation: Autoimmune or Infectious?].

    Science.gov (United States)

    Auw-Hädrich, C; Heinzelmann, S; Coupland, S

    2016-07-01

    Presentation of 3 cases of intraocular inflammation: 1. 47-year old female patient with severe necrotising scleritis and uveitis with underlying granulomatous polyangiitis (formerly known as Wegener granulomatosis, in honour of the German pathologist Friedrich Wegener), known for 10 years. 2. 48-year old male patient with longstanding bilateral uveitis and granulomatous polyangiitis for 2 years. In the histopathological examination of the enucleation specimen, a retrolental tumour turned out to be a granuloma. 3. 57-year old male patient in status post renal transplantation with intraocular cellular infiltration suspicious for lymphoma, which surprisingly proved to be Toxoplasma gondii-associated uveitis. The clinical course and characteristic histological signs and therapeutic options are discussed. PMID:27468098

  9. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  10. An artificial neural network to safely reduce the number of ambulance ECGs transmitted for physician assessment in a system with prehospital detection of ST elevation myocardial infarction

    Directory of Open Access Journals (Sweden)

    Forberg Jakob L

    2012-02-01

    Full Text Available Abstract Background Pre-hospital electrocardiogram (ECG transmission to an expert for interpretation and triage reduces time to acute percutaneous coronary intervention (PCI in patients with ST elevation Myocardial Infarction (STEMI. In order to detect all STEMI patients, the ECG should be transmitted in all cases of suspected acute cardiac ischemia. The aim of this study was to examine the ability of an artificial neural network (ANN to safely reduce the number of ECGs transmitted by identifying patients without STEMI and patients not needing acute PCI. Methods Five hundred and sixty ambulance ECGs transmitted to the coronary care unit (CCU in routine care were prospectively collected. The ECG interpretation by the ANN was compared with the diagnosis (STEMI or not and the need for an acute PCI (or not as determined from the Swedish coronary angiography and angioplasty register. The CCU physician's real time ECG interpretation (STEMI or not and triage decision (acute PCI or not were registered for comparison. Results The ANN sensitivity, specificity, positive and negative predictive values for STEMI was 95%, 68%, 18% and 99%, respectively, and for a need of acute PCI it was 97%, 68%, 17% and 100%. The area under the ANN's receiver operating characteristics curve for STEMI detection was 0.93 (95% CI 0.89-0.96 and for predicting the need of acute PCI 0.94 (95% CI 0.90-0.97. If ECGs where the ANN did not identify a STEMI or a need of acute PCI were theoretically to be withheld from transmission, the number of ECGs sent to the CCU could have been reduced by 64% without missing any case with STEMI or a need of immediate PCI. Conclusions Our ANN had an excellent ability to predict STEMI and the need of acute PCI in ambulance ECGs, and has a potential to safely reduce the number of ECG transmitted to the CCU by almost two thirds.

  11. Intraocular lens with accommodation capacity

    OpenAIRE

    Dorronsoro, Carlos; Alejandre, Nicolás; Bekesi, Nandor; Marcos, Susana

    2014-01-01

    Intraocular lens with accommodation capacity comprising a first optical member (1) having a dynamic optical power, to which a second optical member (2) with a fixed optical power is affixed, in such a manner that at least a central part of each of one of one of the curved surfaces (2a, 2b) of the second optical member (2) and of at least one of the surfaces (1a, 1b) of the first optical member (1) are in contact with each other, the second optical member (2) and the first optical member (1) p...

  12. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  13. Cytomegalovirus retinitis mimicking intraocular lymphoma

    Directory of Open Access Journals (Sweden)

    Patrick Gooi

    2008-12-01

    Full Text Available Patrick Gooi1, James Farmer2, Bernard Hurley3, Elliott Brodbaker41Department of Ophthalmology, University of Calgary, Calgary, Alberta, Canada; 2Department of Pathology and Lab Medicine University of Ottawa and The Ottawa Hospital, Ottawa, Ontario, Canada; 3Department of Ophthalmology, University of Ottawa Eye Institute and The Ottawa Hospital, Ottawa, Ontario, Canada; 4Faculty of Medicine, University of Ottawa, Ottawa, Ontario, CanadaAbstract: We present a case of an unusual retinal infiltrate requiring retinal biopsy for definitive diagnosis. A 62-year-old man with treated lymphoma presented with decreased vision in the right eye associated with a white retinal lesion, which extended inferonasally from an edematous disc. Intraocular lymphoma was considered as a diagnosis; thus, the patient was managed with vitrectomy and retinal biopsy. Cytological analysis of the vitreous aspirate could not rule out a lymphoproliferative disorder. The microbial analysis was negative. Histology of the lesion showed extensive necrosis and large cells with prominent nucleoli. To rule out lymphoma, a battery of immunostains was performed and all were negative. However the limited amount of tissue was exhausted in the process. Subsequently, a hematoxylin and eosin (H/E slide was destained, on which a CMV immunostain was performed. This revealed positivity in the nuclei and intranuclear inclusions within the large atypical cells. A diagnosis of CMV retinitis was made. Retinal biopsy may provide a definitive diagnosis and direct patient care toward intravenous gancyclovir in the case of CMV or toward radiation and chemotherapy for intraocular lymphoma. When faced with a limited amount of tissue, destaining regular H/E slides is a possible avenue to performing additional immunohistochemical studies.Keywords: CMV retinitis, retinal biopsy, immunohistochemistry, destaining

  14. Intraocular cilia associated with perforating injury

    Directory of Open Access Journals (Sweden)

    Gopal Lingam

    2000-01-01

    Full Text Available Purpose: To report a case series of penetrating injury complicated by occurrence of intraocular cilia. Methods: Retrospective analysis of charts of 11 eyes of 11 patients with penetrating injury and intraocular cilia, presenting between September 1978 and November 1998. Ten eyes underwent surgery for trauma-related problems such as cataract, vitritis, retinal detachment etc., at which time intraocular cilia were removed. One eye did not have surgery and continues to harbour cilia at the posterior perforation site. Results: Metallic wire was responsible for injury in 6 of 11 eyes with intraocular cilia. Five eyes had significant intraocular inflammation. The cilia were located in the anterior segment in 4 eyes; in the posterior segment in 6 eyes and in both in one eye. At the last follow up, 72.7% had 6/18 or better vision. Poor vision in the rest was due to recurrent retinal detachment (2 eyes and macular scarring (1 eye. Conclusion: Intraocular cilia are more commonly associated with injury by a metallic wire. The presentation and management of an injured eye does not seem to be influenced by the presence of cilia in the eye.

  15. Effect of osteotomies during rhinoplasty on intraocular pressure

    Directory of Open Access Journals (Sweden)

    Amr N. Rabie

    2016-07-01

    Full Text Available Objective: To investigate whether rhinoplasty with osteotomies for the treatment of deformed nose induces changes in intraocular pressure (IOP. Design: Prospective, nonrandomized study. Setting: University-affiliated medical center. Patients: Thirty patients who underwent rhinoplasty with osteotomies for the nose were prospectively enrolled in this study. Fifteen patients had lateral osteotomies with the external perforating technique, and fifteen with an internal continuous technique with periosteal elevation. We excluded patients with diabetes mellitus, hypertension, glaucoma, previous ocular trauma, history of ocular surgery, and previous use of topical corticosteroid eye drops. Main outcome measures: The intraocular pressure (IOP in each patient was measured by Goldmann tonometry preoperatively and postoperatively on days 1, 2, and 7. Results: 23 women and 7 men with a mean age of 27 years were enrolled in the study. The mean ± SD IOP of the eye was 15.69 ± 2.37 mmHg preoperatively. Postoperatively, the mean ± SD IOPs were 15.96 ± 1.92 mmHg on day 1, 15.45 ± 2.55 mmHg on day 2, and 15.72 ± 2.86 mmHg on day 7 (P = .863. Conclusions: Although osteotomes during rhinoplasty caused variations in the IOP compartment, the changes in IOP were not statistically significant. Therefore, rhinoplasty should be a safe surgical procedure with respect to ocular physiological function, however monitoring IOP peri-operatively is advised. To our best knowledge, this is the first clinical trial to determine the effect of rhinoplasty with osteotomy on intraocular pressure.

  16. Elevating your elevator talk

    Science.gov (United States)

    An important and often overlooked item that every early career researcher needs to do is compose an elevator talk. The elevator talk, named because the talk should not last longer than an average elevator ride (30 to 60 seconds), is an effective method to present your research and yourself in a clea...

  17. Drug-Eluting Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Angel Concheiro

    2011-11-01

    Full Text Available Notable advances in materials science and in surgical techniques make the management of cataract by replacement of the opaque crystalline with an intraocular lens (IOL, one of the most cost-effective interventions in current healthcare. The usefulness and safety of IOLs can be enhanced if they are endowed with the ability to load and to sustain drug release in the implantation site. Drug-eluting IOLs can prevent infections and untoward reactions of eye tissues (which lead to opacification and also can act as drug depots for treatment of several other ocular pathologies. Such a myriad of therapeutic possibilities has prompted the design of drug-IOL combination products. Several approaches are under study, namely combination of the IOL with an insert in a single device, soaking in drug solutions, impregnation using supercritical fluids, coating with drug/polymer layers, and covalent grafting of the drug. The advantages/limitations of each technique are discussed in the present review on selected examples. Although more in vivo data are required, the information already available proves the interest of some approaches in ocular therapeutics.

  18. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  19. Biopsy techniques for intraocular tumors.

    Science.gov (United States)

    Rishi, Pukhraj; Dhami, Abhinav; Biswas, Jyotirmay

    2016-06-01

    Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB) to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous), suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies. PMID:27488148

  20. Surface Modification of Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Qi Huang

    2016-01-01

    Full Text Available Objective: This paper aimed to review the current literature on the surface modification of intraocular lenses (IOLs. Data Sources: All articles about surface modification of IOLs published up to 2015 were identified through a literature search on both PubMed and ScienceDirect. Study Selection: The articles on the surface modification of IOLs were included, but those on design modification and surface coating were excluded. Results: Technology of surface modification included plasma, ion beam, layer-by-layer self-assembly, ultraviolet radiation, and ozone. The main molecules introduced into IOLs surface were poly (ethylene glycol, polyhedral oligomeric silsesquioxane, 2-methacryloyloxyethyl phosphorylcholine, TiO 2 , heparin, F-heparin, titanium, titanium nitride, vinyl pyrrolidone, and inhibitors of cytokines. The surface modification either resulted in a more hydrophobic lens, a more hydrophilic lens, or a lens with a hydrophilic anterior and hydrophobic posterior surface. Advances in research regarding surface modification of IOLs had led to a better biocompatibility in both in vitro and animal experiments. Conclusion: The surface modification is an efficient, convenient, economic and promising method to improve the biocompatibility of IOLs.

  1. Surface Modification of Intraocular Lenses

    Institute of Scientific and Technical Information of China (English)

    Qi Huang; George Pak-Man Cheng; Kin Chiu; Gui-Qin Wang

    2016-01-01

    Objective:This paper aimed to review the current literature on the surface modification of intraocular lenses (IOLs).Data Sources:All articles about surface modification of IOLs published up to 2015 were identified through a literature search on both PubMed and ScienceDirect.Study Selection:The articles on the surface modification of IOLs were included,but those on design modification and surface coating were excluded.Results:Technology of surface modification included plasma,ion beam,layer-by-layer self-assembly,ultraviolet radiation,and ozone.The main molecules introduced into IOLs surface were poly (ethylene glycol),polyhedral oligomeric silsesquioxane,2-methacryloyloxyethyl phosphorylcholine,TiO2,heparin,F-heparin,titanium,titanium nitride,vinyl pyrrolidone,and inhibitors of cytokines.The surface modification either resulted in a more hydrophobic lens,a more hydrophilic lens,or a lens with a hydrophilic anterior and hydrophobic posterior surface.Advances in research regarding surface modification of IOLs had led to a better biocompatibility in both in vitro and animal experiments.Conclusion:The surface modification is an efficient,convenient,economic and promising method to improve the biocompatibility ofIOLs.

  2. Genome-wide analysis of multi-ancestry cohorts identifies new loci influencing intraocular pressure and susceptibility to glaucoma

    NARCIS (Netherlands)

    P.G. Hysi (Pirro); C-Y. Cheng (Ching-Yu); H. Springelkamp (Henriët); S. MacGregor (Stuart); J.N.C. Bailey (Jessica N. Cooke); R. Wojciechowski (Robert); V. Vitart (Veronique); A. Nag (Abhishek); A.W. Hewit (Alex); R. Höhn (René); C. Venturini (Cristina); A. Mirshahi (Alireza); W.D. Ramdas (Wishal); G. Thorleifsson (Gudmar); E.N. Vithana (Eranga); C.C. Khor; A.B. Stefansson (Arni B.); J. Liao (Jie); J.L. Haines (Jonathan); N. Amin (Najaf); Y. Wang (Ying); P.S. Wild (Philipp S.); A.B. Ozel (Ayse B.); J. Li; B.W. Fleck (Brian W.); T. Zeller (Tanja); S.E. Staffieri (Sandra E.); Y.Y. Teo (Yik Ying); G. Cuellar-Partida (Gabriel); X. Luo (Xiaoyan); R.R. Allingham (R Rand); J.E. Richards (Julia); A. Senft (Andrea); L.C. Karssen (Lennart); Y. Zheng (Yingfeng); C. Bellenguez (Céline); L. Xu (Liang); O. Iglesias (Oriol); J.F. Wilson (James F); J.H. Kang (Jae H.); E.M. van Leeuwen (Elisa); V. Jonsson (Vesteinn); U. Thorsteinsdottir (Unnur); D.D.G. Despriet (Dominique); S. Ennis (Sarah); S.E. Moroi (Sayoko); N.G. Martin (Nicholas); N.M. Jansonius (Nomdo); S. Yazar (Seyhan); E.S. Tai (Shyong); P. Amouyel (Philippe); J. Kirwan (James); L.M.E. van Koolwijk (Leonieke); M.A. Hauser (Michael); F. Jonasson (Fridbert); P.J. Leo (Paul); S.J. Loomis (Stephanie J.); R. Fogarty (Rhys); F. Rivadeneira Ramirez (Fernando); L.S. Kearns (Lisa S.); K.J. Lackner (Karl); P.T.V.M. de Jong (Paulus); C.L. Simpson (Claire); C.E. Pennell (Craig); B.A. Oostra (Ben); A.G. Uitterlinden (André); S-M. Saw (Seang-Mei); A.J. Lotery (Andrew); J.E. Bailey-Wilson (Joan E.); A. Hofman (Albert); J.R. Vingerling (Hans); C. Maubaret (Cécilia); A.F.H. Pfeiffer (Andreas); R.C.W. Wolfs (Roger); H.G. Lemij (Hans); T.L. Young (Terri); L.R. Pasquale (Louis); C. Delcourt (Cécile); T.D. Spector (Timothy); C.C.W. Klaver (Caroline); K.S. Small (Kerrin); K.P. Burdon (Kathryn); J-A. Zwart (John-Anker); T.Y. Wong (Tien); A.C. Viswanathan (Ananth); D.A. Mackey (David); J.E. Craig (Jamie); J.L. Wiggs (Janey); C.M. van Duijn (Cock); C.J. Hammond (Christopher); T. Aung (Tin)

    2014-01-01

    textabstractElevated intraocular pressure (IOP) is an important risk factor in developing glaucoma, and variability in IOP might herald glaucomatous development or progression. We report the results of a genome-wide association study meta-analysis of 18 population cohorts from the International Glau

  3. Late opacification of a hydrophilic acrylic intraocular lens

    Directory of Open Access Journals (Sweden)

    Al-Bdour Muawyah

    2008-01-01

    Full Text Available Cataract extraction and intraocular lens implantation is considered to be a safe procedure in most cases. However, the new advances in the surgical technique namely phacoemulsification and hence the increased use of foldable intraocular lenses have given rise to new complications including late opacification of intraocular lenses. In this case we report late opacification of a foldable hydrophilic acrylic intraocular lens and the surgical technique for its exchange.

  4. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    Directory of Open Access Journals (Sweden)

    Emre Güler

    2014-03-01

    Full Text Available Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalmol 2014; 44: 156-7

  5. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    OpenAIRE

    Emre Güler; Aylin Tenlik; Tuba Kara Akyüz

    2014-01-01

    Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalm...

  6. 新型目的层预约的人工免疫电梯群控策略%Elevator Group Control Policy with New Destination Registration Based on Artificial Immune Algorithm

    Institute of Scientific and Technical Information of China (English)

    朱盐; 刘跃敏

    2012-01-01

    电梯群控系统中轿厢内人数大多用称重装置和监视器进行估算,很难得到准确值,提出一种采集所有乘客信息,个性化派梯的新型目的层预约电梯群控系统,可以实时掌握电梯拥挤度,更为合理地进行派梯调度.人工免疫算法多样性好、鲁棒性强、隐含并行性等,但是其收敛速度相对较慢,提出一种加入扰动选择算子的改进人工免疫算法加快其后期收敛速度,将两种算法应用于目的层预约电梯群控系统中进行派梯,仿真结果表明:与标准免疫算法对比,改进算法在层间均衡交通流和上、下高峰交通流下均有一定程度的提高,高峰交通流下提高显著.%In elevator group control system, the passengers number of elevator is estimated always by the weighing device and monitor, it's hard to get the accurate value, so a elevator group control policy with new destination registration was presented which can collect all passengers information and perform a personalized dispatching program, this algorithm can obtain the elevator congestion level real-time, so go on dispatching more reasonably. Artificial immune algorithm has some advantages in diversity, robustness, implicit parallelism and so on, but its convergence rate is slowly relatively, then proposed an improved artificial immune algorithm with disturbance selection operator so as to speed up the convergence rate in late, and put these two algorithms into elevator group control system with destination registration for dispatching. Simulation results show that comparing the standard immune algorithm, the improved algorithm has increased a lot in the balanced traffic flow between floors, the traffic flow at upper or lower peak to some extent, and increased significantly at the peak traffic flow.

  7. Impact of the Topical Ophthalmic Corticosteroid Loteprednol Etabonate on Intraocular Pressure

    OpenAIRE

    Sheppard, John D.; Timothy L Comstock; Cavet, Megan E.

    2016-01-01

    Corticosteroids are a mainstay therapeutic option for the treatment of ocular inflammation. However, safety remains a concern for clinicians, particularly with long-term use. Though highly effective at suppressing inflammatory and allergic responses, topical ophthalmic corticosteroids carry an inherent risk of side effects, including elevated intraocular pressure (IOP), a risk factor for the development of glaucoma. The corticosteroid loteprednol etabonate (LE) contains an ester rather than a...

  8. 21 CFR 886.4300 - Intraocular lens guide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens guide. 886.4300 Section 886.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device...

  9. 23-gauge Transconjunctival Sutureless Vitrectomy in Eyes with Posteriorly Dislocated Intraocular Lens after Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Fatih Horozo¤lu

    2011-08-01

    Full Text Available Purpose: To evaluate the outcomes of 23-gauge (23-G transconjunctival sutureless vitrectomy (TSV in eyes with posteriorly dislocated intraocular lens (IOL after cataract surgery. Material and Method: In this retrospective study, we evaluated 6 eyes of 6 consecutive cases with posteriorly dislocated intraocular lens after cataract surgery between April 2007 and November 2010. Visual acuity, intraocular pressure, detailed fundus examination and details of surgery were recorded. Results: The mean age of the patients was 64.7 years and the mean follow-up was 5.5 months (3-12 months. All eyes received 23-G TSV. Dislocated IOL was removed from the vitreous and implanted into ciliary sulcus in 2 eyes (33.3% with polymethylmetacrilate IOL and in 4 eyes (66.7% with 3-piece hydrophilic acrylic IOL. In 5 of the 6 eyes (83.7%, visual acuity improved postoperatively. In one eye (16.7%, elevation of intraocular pressure was observed postoperatively and controlled by topical treatment. Discussion: 23-G TSV surgery may be used in eyes with posteriorly IOLs after cataract surgery. Studies with a larger number of patients would better demonstrate the efficacy of this method. (Turk J Ophthalmol 2011; 41: 213-6

  10. Design of a Test Bench for Intraocular Lens Optical Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Alba-Bueno, Francisco; Vega, Fidel; Millan, Maria S, E-mail: francisco.alba-bueno@upc.edu, E-mail: fvega@oo.upc.edu, E-mail: millan@oo.upc.edu [Departamento de Optica y Optometria, Universidad Politecnica de Cataluna, C/ Violinista Vellsola 37, 08222 Terrassa (Spain)

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  11. Design of a Test Bench for Intraocular Lens Optical Characterization

    Science.gov (United States)

    Alba-Bueno, Francisco; Vega, Fidel; Millán, María S.

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  12. Closed intraocular microsurgery in ocular trauma.

    Science.gov (United States)

    Kanski, J J

    1978-04-01

    A series of 53 eyes that had suffered severe trauma was treated by closed intraocular microsurgery with vitreous cutters. The cases were divided into three categories: (a) anterior segment reconstruction for traumatic cataracts and post-traumatic pupillary membranes, (b) vitreous haemorrhage with and without retinal detachment, and (c) traumatically dislocated lenses.

  13. Associations with intraocular pressure across Europe

    DEFF Research Database (Denmark)

    Khawaja, Anthony P; Springelkamp, Henriët; Creuzot-Garcher, Catherine;

    2016-01-01

    Raised intraocular pressure (IOP) is the most important risk factor for developing glaucoma, the second commonest cause of blindness globally. Understanding associations with IOP and variations in IOP between countries may teach us about mechanisms underlying glaucoma. We examined cross-sectional...

  14. Clinical analysis of long-term artificial lens dislocation after phakic irisfixated intraocular lens implantation%有晶状体眼虹膜固定型人工晶状体植入术后远期人工晶状体脱位临床分析

    Institute of Scientific and Technical Information of China (English)

    张莹; 谭少建; 李霞; 刘彩娟; 梁皓

    2015-01-01

    目的 探讨有晶状体眼虹膜固定型有晶状体眼人工晶状体(phakic intraocular lens,PIOL)植入术后远期人工晶状体脱位、移位情况及原因分析.方法 对我中心2005至2013年开展的Verisyse PIOL植入术矫正高度近视患者52例(104眼)进行术后平均6.5a随访性研究,对其中发生PIOL脱位、移位患者的临床资料进行回顾性分析.结果 104眼中8眼发生PIOL不全脱位,其中1眼是因为拳头打伤颞侧晶状体袢脱落,2眼因皮球打伤眼睛致一侧晶状体袢脱落,1眼因撞击后出现鼻侧晶状体袢脱落,2眼是搬动重物一侧晶状体袢脱落,1眼是自然分娩后出现双侧晶状体袢脱落并PIOL脱落入前房,1眼是夹持虹膜部位退行性改变致晶状体脱位.7眼发生PIOL下移,下移程度>0.5 mm,其中晶状体袢单侧下移2眼,双侧下移5眼.8眼PIOL脱位中6眼行PIOL再固定术,2眼行PIOL取出术.结论 PIOL脱位与术后眼部外力及外伤、眼压波动、手术时固定虹膜组织的程度不够、所夹取的虹膜组织发生脱色素和退行性变有关,PIOL本身有自身的重量,长期作用会发生向下移位或襻脱离.%Objective To explore the long-term postoperative dislocation and displacement of intraocular lens after Verisyse phakic intraocular lens (Verisyse PIOL) implantation,and analyze the reasons of dislocation and displacement of intraocular lens.Methods Based on the random survey carried out on 52 cases who have received Verisyse PIOL implantation for correction of high myopia in our center from 2005 to 2013,the follow-up time averaged 6.5 years,the cases of dislocation and displacement of intraocular lens were retrospectively analyzed.Results In 104 eyes,PIOL in 8 eyes appeared incomplete dislocations,including 1 eye with temporal crystal loop loss resulted from punching,2 eyes with side crystal loop losses induced by ball-beating,1 eye with nasal crystal loop loss due to impact,2 eyes with side crystal loop losses

  15. Effect of pegaptanib sodium 0.3 mg intravitreal injections (Macugen) in intraocular pressure

    DEFF Research Database (Denmark)

    Boyer, David S; Goldbaum, Mauro; Leys, Anita M;

    2014-01-01

    OBJECTIVE: To assess the rate of pegaptanib-associated sustained intraocular pressure (IOP) elevation. METHODS: A posthoc analysis was conducted on all IOP measurements, except the immediate 30-min postinjection, from all subjects randomised to pegaptanib 0.3 mg or sham injections continuously in...... lowering medication added during the course of the study. No subject required glaucoma surgery. CONCLUSIONS: In V.I.S.I.O.N., after 2 years, there was no evidence of sustained IOP elevation associated with pegaptanib 0.3 mg use. TRIAL REGISTRATION NUMBER: NCT00321997....

  16. Characterizing intraocular tumors with photoacoustic imaging

    Science.gov (United States)

    Xu, Guan; Xue, Yafang; Gursel, Zeynep; Slimani, Naziha; Wang, Xueding; Demirci, Hakan

    2016-03-01

    Intraocular tumors are life-threatening conditions. Long-term mortality from uveal melanoma, which accounts for 80% of primary intraocular tumors, could be as high as 25% depending on the size, ciliary body involvement and extraocular extension. The treatments of intraocular tumors include eye-sparing approaches such as radiotherapy and thermotherapy, and the more aggressive enucleation. The accurate diagnosis of intraocular tumors is thereby critical in the management and follow-up of the patients. The diagnosis of intraocular tumors is usually based on clinical examination with acoustic backscattering based ultrasonography. By analyzing the high frequency fluctuations within the ultrasound (US) signals, microarchitecture information inside the tumor can be characterized. However, US cannot interrogate the histochemical components formulating the microarchitecture. One representative example is the inability of US imaging (and other contemporary imaging modalities as well) in differentiating nevoid and melanoma cells as the two types of cells possesses similar acoustic backscattering properties. Combining optical and US imaging, photoacoustic (PA) measurements encode both the microarchitecture and histochemical component information in biological tissue. This study attempts to characterize ocular tumors by analyzing the high frequency signal components in the multispectral PA images. Ex vivo human eye globes with melanoma and retinoblastoma tumors were scanned using less than 6 mJ per square centimeters laser energy with tunable range of 600-1700 nm. A PA-US parallel imaging system with US probes CL15-7 and L22-14 were used to acquire the high frequency PA signals in real time. Preliminary results show that the proposed method can identify uveal melanoma against retinoblastoma tumors.

  17. Experimental study on cyclosporine A drug delivery system in prevention of posterior capsule opacification after intraocular lens implantation in rabbits

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Objective To study the effect of cyclosporine A drug delivery system (CsA-DDS) on the prevention of posterior capsule opacification (PCO) after experimental intraocular lens implantation in rabbit eyes. Methods Twenty healthy New Zealand white rabbits, whose left eyes and right eyes were used respectively as experiment eyes and controls, were subjected to extracapsular lens extraction and artificial lens implantation. During the operation, CsA-DDS with poly (lactideco-glycolide) as carriers or empty DDS was...

  18. Avaliação comparativa do efeito dos colírios de apraclonidina e latanoprost na profilaxia da hipertensão ocular pós capsulotomia com YAG Laser em pacientes não glaucomatosos Profilatic use of apraclonidine and latanoprost to prevent intraocular pressure elevation following Nd:YAG laser posterior capsulotomy

    Directory of Open Access Journals (Sweden)

    Juliane de Freitas S. Paranhos

    1999-10-01

    Full Text Available Objetivo: Comparar a eficácia do latanoprost 0,005% e da apraclonidina 1% na prevenção da hipertensão ocular pós-capsulotomia posterior com YAG laser, em pacientes não- glaucomatosos. Método: Trinta e seis pacientes (36 olhos incluídos foram divididos em três grupos que usaram latanoprost 0,005%, apraclonidina 1% ou placebo. Foram realizadas medidas da pressão ocular antes da instilação de qualquer colírio, 30 minutos após a dilatação, 1 hora e 4 horas após o YAG laser. Resultados: Não houve diferença significativa entre os 3 grupos em relação à idade, pressão ocular inicial e pós-dilatação, assim como em quantidade de energia utilizada. Na primeira hora, tanto para a diferença absoluta quanto para o percentual de alteração da pressão intra-ocular, o grupo da apraclonidina apresentou redução estatisticamente maior em relação ao grupo controle (p 0,05. Na 4a. hora não houve diferença significativa entre os grupos (p > 0,05. As medidas de pressão nos 4 intervalos não apresentaram variação estatisticamente significativa (p > 0,05. A quantidade de energia utilizada não mostrou correlação significativa com o aumento da Po (p > 0,05. Conclusão: A apraclonidina 1% apresentou maior eficácia na profilaxia da hipertensão após capsulotomia posterior com YAG laser quando comparada com latanoprost 0,005%.Purpose: To compare the efficacy of 0.005% latanoprost and 1% apraclonidine in the prevention of an increase of intraocular pressure (IOP after Nd: YAG laser capsulotomy in nonglaucomatous patients. Methods: Thirty-six patients were included and divided in to three groups. Patients received 0.005% latanoprost. 1% apraclonidine or placebo. Four measurements of IOP were made: before instillation of any drug, 30 minutes after cycloplegia, 1 hour and 4 hours after laser. Results: No significant difference was found between the three groups regarding age, initial intraocular pressure, pressure 30 minutes after

  19. Management of dislocated intraocular implants.

    Science.gov (United States)

    Chan, C K; Agarwal, A; Agarwal, S; Agarwal, A

    2001-12-01

    Implant dislocation may occur in the absence of appropriate capsular or zonular support (PCIOL) (11,35,53) or following traumatic injury to anterior ocular tissues (ACIOL). (11,19,20) Other factors (e.g., advanced patient age, high myopia, previous vitrectomy, pseudoexfoliation syndrome, and certain connective tissue disorders) also may predispose implant dislocation. (9,52) Although reported for all types of IOLs, implant dislocation is becoming more manageable because of the advancement of surgical techniques. A dislocated ACIOL or PCIOL may be explanted, exchanged, or repositioned. (11,48,71) Repositioning the dislocated PCIOL in the ciliary sulcus with modern vitreoretinal techniques provides an optimal environment for visual recovery. (11,71) Implant repositioning techniques generally may be categorized into the external or the internal approaches. (8,11) The former involves external suturing methods for a primary or secondary implant in the absence of adequate capsular or zonular support (15,16,31,42,56,60,61,64,66,73,76) and the latter is achieved through modern pars plana techniques. 8,11,62,69) Recently, several implant repositioning methods gaining increasing acceptance include the scleral loop fixation, (45) the snare approach, (43) the use of the 25-gauge implant forceps, (13) temporary haptic externalization, (8,11,36,71) and the use of perfluorocarbon liquids. (1,28,40,41,44) The temporary haptic externalization method combines the best features of the external and the internal approaches, avoids complex intraocular maneuvers, and allows precise scleral fixation of the dislocated IOL on a consistent basis. (8,11,71) Endoscopy provides the surgeon with optimal viewing of the anterior retropupillary anatomy that is often difficult to appreciate (e.g., capsular-zonular complex, ciliary sulcus, anterior retina, and vitreous base). (6,11) As a result, precise haptic placement is possible during the repositioning process. (6,11) However, a three

  20. [Results of intraocular lens implantation in cataract complicated by medium and high myopia].

    Science.gov (United States)

    Plotnikova, Iu A; Chuprov, A D; Volkov, D V

    2001-01-01

    Results of surgical treatment of cataract complicated by medium and high myopia are analyzed. The main group consisted of 90 patients (96 eyes) subjected to extracapsular cataract extraction with implantation of posterior-chamber intraocular lenses and the reference group of 128 patients in whom cataract was extracted without implantation of artificial lens. The study included creation of a mathematical model of myopic eye with estimation of pressure fluctuations in various zones of the eye, developing during transposition of the vitreous during patient's movements (head movements, jumps, falling) and the damping effect of the lens in the ocular system. It was proven by mathematical calculations that transpositions of jelly fractions of the vitreous decreased by 70% in an eye with the lens in comparison with their transposition in aphakia. Clinical studies demonstrated the efficiency of intraocular correction of aphakia in high myopia: implantation of an intraocular lens decreases the risk of detachment of the retina during the postoperative period and helps attain the desired refraction. PMID:11765458

  1. Characteristics of Optic Nerve Damage Induced by Chronic Intraocular Hypertension in Rat

    Institute of Scientific and Technical Information of China (English)

    Jiantao Wang; Jian Ge; A.A. Sadun; T.T. Lam

    2004-01-01

    Purpose:To set up the Sharma's chronic intraocular hypertension model and investigate the intraocular pressure (lOP) as well as the optic nerve damage of this model in rat.Methods:The operations of the chronic intraocular hypertension model were performed as described by Sharma in 60 male Lewis albino rats. IOP was measured using the TonoPen XL immediately after surgery and then at 5 day, 2 week or 4 week intervals. Cresyl violet staining of whole-mounted retinas was used to label retinal ganglion cells (RGCs),then RGCs were counted. Paraphenylenediamine (PPD) staining was performed in the semi-thin cross sections of optic nerve of rat, in order to know whether the axons of optic nerve were degenerated or not. Results:There were 47 rats with higher IOP after the episcleral veins cauterized in 60rats. The ratio of elevated IOP was 78.3%. The IOPs were stable in 4 weeks. After cresyl violet staining, the RGCs loss was 11.0% and 11.3% was found in the central and peripheral retina respectively after 2 weeks of increased IOP. After 4 weeks of increased lOP, the loss of RGCs was 17% for the central retina and 24.6% for the peripheral retina. In the retinas without higher IOP, there was no loss of RGCs. PPD staining showed that optic nerve of rat with about 5.3% damage of axons located at the superior temporal region. Region of affected optic nerve 1 mm posterior to the globe by light microscope showed evidence of damaged axons with axonal swelling and myelin debris.Conclusion:Sharma's chronic intraocular hypertension model is a reproducible and effective glaucoma model, which mimics human glaucoma with chronically elevation IOP and induced RGCs loss and damage of optic nerve. Eye Science 2004;20:25-29.

  2. The Visual Effects of Intraocular Colored Filters

    Directory of Open Access Journals (Sweden)

    Billy R. Hammond

    2012-01-01

    Full Text Available Modern life is associated with a myriad of visual problems, most notably refractive conditions such as myopia. Human ingenuity has addressed such problems using strategies such as spectacle lenses or surgical correction. There are other visual problems, however, that have been present throughout our evolutionary history and are not as easily solved by simply correcting refractive error. These problems include issues like glare disability and discomfort arising from intraocular scatter, photostress with the associated transient loss in vision that arises from short intense light exposures, or the ability to see objects in the distance through a veil of atmospheric haze. One likely biological solution to these more long-standing problems has been the use of colored intraocular filters. Many species, especially diurnal, incorporate chromophores from numerous sources (e.g., often plant pigments called carotenoids into ocular tissues to improve visual performance outdoors. This review summarizes information on the utility of such filters focusing on chromatic filtering by humans.

  3. Intraocular pressure in Japanese diabetic patients

    OpenAIRE

    Matsuoka M; Ogata N.; Matsuyama K; Yoshikawa T.; Takahashi K.

    2012-01-01

    Masato Matsuoka,1 Nahoko Ogata,2 Kayako Matsuyama,1 Tadanobu Yoshikawa,1 Kanji Takahashi31Department of Ophthalmology, Kansai Medical University, Takii Hospital, Osaka, 2Department of Ophthalmology, Nara Medical University, Nara, 3Department of Ophthalmology, Kansai Medical University, Hirakata Hospital, Osaka, JapanBackground: To determine whether the intraocular pressure (IOP) in diabetic patients is significantly different from that in nondiabetic patients.Methods: The medical records of a...

  4. Environmental standards for intraocular lens implantation.

    Science.gov (United States)

    Crawford, B A; Kaufman, D V

    1984-02-01

    Successful implantation of prosthetic devices depends upon their freedom from postoperative inflammation and infection. Techniques and lessons learned in orthopaedic and other implant surgery should be applied to intraocular lens implantation. The avoidance of contamination by particles and micro-organisms is one essential principle of the surgical procedure. Practical steps are described to reduce both types of contamination. These measures taken together are recommended for adoption as a standard of environmental safety for lens implantation.

  5. Adherence of Staphylococcus epidermidis to intraocular lenses.

    OpenAIRE

    Griffiths, P G; Elliot, T. S.; McTaggart, L

    1989-01-01

    We have demonstrated, with an in vitro model, that Staphylococcus epidermidis is able to colonise intraocular lenses. Adherent organisms were quantitated by light microscopy, scanning electron microscopy, and viable counting. Bacterial adherence was associated with production of a polysaccharide glycocalyx. Organisms which were attached to the lenses were resistant to apparently bactericidal concentrations of antibiotics, as determined by conventional testing. We speculate on the role of colo...

  6. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    OpenAIRE

    Elena Bonafonte Marquez; Sergio Bonafonte Royo

    2015-01-01

    We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL) implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for i...

  7. Introduction to the development of intraocular lens

    Science.gov (United States)

    Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2013-08-01

    In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.

  8. File list: DNS.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.20.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  9. File list: DNS.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.10.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  10. File list: DNS.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.50.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  11. File list: DNS.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.05.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  12. Artificial intelligence

    CERN Document Server

    Hunt, Earl B

    1975-01-01

    Artificial Intelligence provides information pertinent to the fundamental aspects of artificial intelligence. This book presents the basic mathematical and computational approaches to problems in the artificial intelligence field.Organized into four parts encompassing 16 chapters, this book begins with an overview of the various fields of artificial intelligence. This text then attempts to connect artificial intelligence problems to some of the notions of computability and abstract computing devices. Other chapters consider the general notion of computability, with focus on the interaction bet

  13. Quality of vision through diffractive bifocal intraocular lenses.

    OpenAIRE

    Jay, J L; Chakrabarti, H S; Morrison, J D

    1991-01-01

    Two elderly women have each received a monofocal intraocular lens in one eye and a 3M diffractive bifocal intraocular lens in the other eye. Both eyes were shown to have equivalent retinal/neural function by measuring contrast sensitivity to laser interference fringes which bypassed refractive and other defects of the ocular media. The eyes with a bifocal intraocular lens displayed a much greater depth of focus, though at the expense of diminished contrast sensitivity compared with the normal...

  14. Effect of a tight necktie on intraocular pressure

    OpenAIRE

    Božić Marija; Hentova-Senćanin Paraskeva; Branković Aleksandra; Marjanović Ivan; Jocić Đorđević Jasmina; Senćanin Ivan

    2012-01-01

    Introduction. Any factor causing constriction of the neck may lead to an increase in intraocular pressure. A tight necktie may result in increasing intraocular pressure, which could lead to an erroneous diagnosis and treatment of ocular hypertension or even glaucoma. This study was aimed at evaluating the effect of a tight necktie on intraocular pressure measurement using Goldmann applanation tonometry. Material and Methods. This study included forty eyes of 20 patients with primary ope...

  15. Clinical Observation of 126 Cases of Sutureless Phacoemulsification with PMMA Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Yanshuang Yan; Zhengxing Mao

    2000-01-01

    Objective: To observe the safety and effect of sutureless phacoemulsification with PMMA intraocular lens (IOL) implantation.Methods: One-hundred and twenty-six cases (126 eyes) of sutureless phacoemulsification with PMMA intraocular lens (IOL) implantation were retrospected and evaluated. The surgeries were performed through a limbal tunnel incision. PMMA IOLs with 5.5mm or 6.0mm in diameter were implanted.Results: The follow-up was 3~20 months. Visual acuity of 0. 5 or better was obtained in 120 cases (95.2%), and that of 1.0 or better was obtained in 89 cases (70. 6% ).Intra-operative complications included posterior capsule rupture in 9 cases (7. 1% ) and iris injury in 7 cases(5.6% ). Postoperative complications included early corneal edema in 96 cases(76.2% ), transient intraocular pressure elevation in 5 cases(4. 3%),remnant of cortex in 1 case and leakage of incision in 1 case. M1 were properly managed with good results.Conclusion: Sutureless phacoemulsification with PMMA IOL implantation is safe even in grass-root hospitals where cataracts are harder.

  16. Intraocular lens power estimation by accurate ray tracing for eyes underwent previous refractive surgeries

    Science.gov (United States)

    Yang, Que; Wang, Shanshan; Wang, Kai; Zhang, Chunyu; Zhang, Lu; Meng, Qingyu; Zhu, Qiudong

    2015-08-01

    For normal eyes without history of any ocular surgery, traditional equations for calculating intraocular lens (IOL) power, such as SRK-T, Holladay, Higis, SRK-II, et al., all were relativley accurate. However, for eyes underwent refractive surgeries, such as LASIK, or eyes diagnosed as keratoconus, these equations may cause significant postoperative refractive error, which may cause poor satisfaction after cataract surgery. Although some methods have been carried out to solve this problem, such as Hagis-L equation[1], or using preoperative data (data before LASIK) to estimate K value[2], no precise equations were available for these eyes. Here, we introduced a novel intraocular lens power estimation method by accurate ray tracing with optical design software ZEMAX. Instead of using traditional regression formula, we adopted the exact measured corneal elevation distribution, central corneal thickness, anterior chamber depth, axial length, and estimated effective lens plane as the input parameters. The calculation of intraocular lens power for a patient with keratoconus and another LASIK postoperative patient met very well with their visual capacity after cataract surgery.

  17. Evaluation of intraocular lens implant location in the eyeball basing on the Purkinje images

    Science.gov (United States)

    Jóźwik, A.; Siedlecki, D.; Zajac, M.

    2012-01-01

    Intraocular lens (IOL) is an artificial implant substituting natural crystalline lens which is non-transparent due to cataract. Incorrect location of the IOL in the eyeball (e.g. its shift or tilt) causes significant deterioration of patient's vision. The analysis of Purkinje images (i.e. reflections from successive refracting surfaces in the eye) enables to determine the real IOL location and thus helps in evaluating the retinal image quality. The experimental setup for Purkinje images recording consists of illuminator, composed of a number of infrared LEDs, telecentric lens and detector (CCD camera). Analysis of mutual position of particular reflections enables to evaluate the lens location in respect to the corneal axis. The actual measurements are realized on artificial eye model, what allows to estimate the precision of the algorithm applied in the calculations. In the future the experimental set-up will be adapted to measure the eyes of real patients.

  18. Artificial Limbs

    Science.gov (United States)

    ... you are missing an arm or leg, an artificial limb can sometimes replace it. The device, which ... activities such as walking, eating, or dressing. Some artificial limbs let you function nearly as well as ...

  19. Mirtogenol® potentiates latanoprost in lowering intraocular pressure and improves ocular blood flow in asymptomatic subjects

    OpenAIRE

    Schonlau, Frank

    2010-01-01

    Robert D Steigerwalt Jr1, Gianni Belcaro1, Paolo Morazzoni2, Ezio Bombardelli2, Carolina Burki3, Frank Schönlau4 1Department of Biomedical Sciences, University of Chieti-Pescara, San Valentino, Italy; 2Indena S.p.A. Scientific Department, Milan, Italy; 3Horphag Research (UK) Ltd., Geneva, Switzerland; 4Horphag Research (UK) Ltd. South Kensington, London UKPurpose: The dietary supplement Mirtogenol® was previously shown to lower elevated intraocular pressure (IOP). We here pre...

  20. Intraocular lymphoma after cardiac transplantation: Magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yi Kyung; Kim, Hyung Jin; Woo, Kyung In; Kim, Yoon Duck [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2013-01-15

    We report a case of intraocular lymphoma in a 65-year-old man, 15 months after cardiac transplantation. On Magnetic Resonance (MR) images, the iris and the anterior chamber of the right eye were found to be involved with an enhancing soft-tissue lesion. To our knowledge, this is the first case of post-transplantation intraocular lymphoma evaluated with MR imaging.

  1. Out-of-the-bag intraocular lens dislocation: outcomes of posterior chamber intraocular lens exchange, risk factors, and prevention

    Institute of Scientific and Technical Information of China (English)

    ZHENG Dan-ying; CHEN Li-na; SUN Yi; SHAO Ying-feng; LIANG Jing-li; LIU Yi-zhi

    2010-01-01

    Background Dislocation of posterior chamber intraocular lens is one of the most common complications of intraocular lens implantation. Lens exchange is an effective solution to this unsatisfactory status. This study was conducted to analyze the possible predisposing factors for out-of-the-bag posterior chamber intraocular lens dislocation and to study the outcomes of lens exchange surgery.Methods Thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation who underwent posterior chamber intraocular lens exchange in Zhongshan Ophthalmic Center of Sun Yat-sen University (Guangdong,China) from January 2003 to October 2009 were included. A 6-month follow-up was completed. The causes for out-of-the-bag intraocular lens dislocation and visual outcomes of posterior chamber intraocular lens exchange were analyzed. The out-of-the-bag intraocular lens dislocation was diagnosed on the basis of the findings from slit-lamp microscope and B-ultrasound. The dislocated intraocular lens was explanted. Reimplantation of a new posterior chamber intraocular lens was performed in each case using standardized surgical procedures.Results In this study, a total of thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation underwent posterior chamber intraocular lens exchange surgery. Causes for out-of-the-bag intraocular lens dislocation included posterior capsule rupture during the initial cataract extraction procedure (23 eyes, 63.8%), trauma (5 eyes,13.9%), neodymium-doped yttrium aluminium garnet (Nd:YAG) laser-induced dislocation (2 eyes, 5.6%), the status after vitrectomy (2 eyes, 5.6%) and unidentifiable etiology (4 eyes, 11.1%). Symptoms of these patients mainly included decrease in visual acuity (17 cases, 47.2%), blurred vision (16 cases, 44.4%), glare (1 case, 2.8%), diplopia (1 case,2.8%), and halo (1 case, 2.8%). Intraocular lens dislocation into the posterior vitreous cavity (29 eyes, 80.5%), anterior chamber (1

  2. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    Directory of Open Access Journals (Sweden)

    Elena Bonafonte Marquez

    2015-01-01

    Full Text Available We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for it could be the only sign of secondary glaucoma.

  3. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  4. Effect of a tight necktie on intraocular pressure

    Directory of Open Access Journals (Sweden)

    Božić Marija

    2012-01-01

    Full Text Available Introduction. Any factor causing constriction of the neck may lead to an increase in intraocular pressure. A tight necktie may result in increasing intraocular pressure, which could lead to an erroneous diagnosis and treatment of ocular hypertension or even glaucoma. This study was aimed at evaluating the effect of a tight necktie on intraocular pressure measurement using Goldmann applanation tonometry. Material and Methods. This study included forty eyes of 20 patients with primary open angle glaucoma and 20 healthy controls (all male. Intraocular pressure was measured without a necktie, 3 minutes after placing a tight necktie and 3 minutes after loosening it. Student’s t-test was used to analyze the data between two groups. The intraocular pressure measurements were subjected to paired t - test. The value p < 0.05 was considered statistically significant. A possible correlation between the age of subjects and intraocular pressure values was analyzed using linear regression (Pearson′. Results. A statistically significant difference was found in intraocular pressure readings in all three measurements between two tested groups (p<0.05. When analyzed within groups, statistical significance in intraocular pressure readings was found after loosening the necktie (<0.05. No correlation between the age of subjects and increased intraocular pressure was found in either tested group of subjects after the necktie had been tightened (r2=0.006, p=0.70 for primary open angle patients, r2=0.07, p=0.22 for healthy controls. Conclusion. Wearing a tight necktie for a limited period of time during the day could be considered as a possible risk factor for glaucoma development.

  5. Lente intra-ocular multifocal difrativa apodizada: resultados Diffractive apodized multifocal intraocular lens: results

    Directory of Open Access Journals (Sweden)

    Virgilio Centurion

    2007-12-01

    Full Text Available OBJETIVO: Mostrar os resultados visuais e refracionais com lente intra-ocular multifocal difrativa apodizada. MÉTODOS: Estudo de 100 olhos de 50 pacientes com catarata, submetidos à facoemulsificação com implante bilateral de lente intra-ocular (LIO multifocal difrativa apodizada. Foi avaliada a acuidade visual binocular sem e com correção para longe e perto, a previsibilidade refracional e a freqüência de uso de óculos. RESULTADOS: A acuidade visual sem correção para longe foi de e " 20/30 em 97,56% dos olhos operados e e" J2 em 100%, sendo que 82% dos pacientes nunca usam óculos e 16% usam de forma esporádica. CONCLUSÃO: A LIO multifocal difrativa apodizada mostrou ser uma opção previsível, reproduzível e segura na correção dos vícios de refração para longe e perto durante a cirurgia da catarata, permitindo elevado índice de independência ao uso de óculos.OBJECTIVE: To show visual and refraction results using multifocal diffractive apodized intraocular lens. METHODS: The study of 100 eyes of 50 patients with cataract, submitted to phacoemulsification with bilateral implant of multifocal diffractive apodized intraocular lens (IOL. Binocular visual acuity was evaluated with and without correction for near and distance, and refraction previsibility and frequency of wearing glasses. RESULTS: Visual acuity without correction for distance was e" 20/30 in 97.56% of eyes operated on and e" J2 in 100%, of these 82% of patients never wear glasses and 16% wear glasses sporadically. CONCLUSION: Multifocal diffractive apodized IOL proved to be a foreseeable option, reproducible and safe in the correction of refraction errors for distance and near during cataract surgery, enabling a high rate of independence from the use of glasses.

  6. MicroRNA profiling in intraocular medulloepitheliomas.

    Directory of Open Access Journals (Sweden)

    Deepak P Edward

    Full Text Available To study the differential expression of microRNA (miRNA profiles between intraocular medulloepithelioma (ME and normal control tissue (CT.Total RNA was extracted from formalin fixed paraffin embedded (FFPE intraocular ME (n=7 and from age matched ciliary body controls (n=8. The clinical history and phenotype was recorded. MiRNA profiles were determined using the Affymetrix GeneChip miRNA Arrays analyzed using expression console 1.3 software. Validation of significantly dysregulated miRNA was confirmed by quantitative real-time PCR. The web-based DNA Intelligent Analysis (DIANA-miRPath v2.0 was used to perform enrichment analysis of differentially expressed (DE miRNA gene targets in Kyoto Encyclopedia of Genes and Genomes (KEGG pathway.The pathologic evaluation revealed one benign (benign non-teratoid, n=1 and six malignant tumors (malignant teratoid, n=2; malignant non-teratoid, n = 4. A total of 88 miRNAs were upregulated and 43 miRNAs were downregulated significantly (P<0.05 in the tumor specimens. Many of these significantly dysregulated miRNAs were known to play various roles in carcinogenesis and tumor behavior. RT-PCR validated three significantly upregulated miRNAs and three significantly downregulated miRNAs namely miR-217, miR-216a, miR-216b, miR-146a, miR-509-3p and miR-211. Many DE miRNAs that were significant in ME tumors showed dysregulation in retinoblastoma, glioblastoma, and precursor, normal and reactive human cartilage. Enriched pathway analysis suggested a significant association of upregulated miRNAs with 15 pathways involved in prion disease and several types of cancer. The pathways involving significantly downregulated miRNAs included the toll-like receptor (TLR (p<4.36E-16 and Nuclear Factor kappa B (NF-κB signaling pathways (p<9.00E-06.We report significantly dysregulated miRNAs in intraocular ME tumors, which exhibited abnormal profiles in other cancers as well such as retinoblastoma and glioblastoma. Pathway analysis

  7. Energy Efficiency of a New Trifocal Intraocular Lens

    Science.gov (United States)

    Vega, F.; Alba-Bueno, F.; Millán, M. S.

    2014-01-01

    The light distribution among the far, intermediate and near foci of a new trifocal intraocular lens (IOL) is experimentally determined, as a function of the pupil size, from image analysis. The concept of focus energy efficiency is introduced because, in addition to the theoretical diffraction efficiency of the focus, it accounts for other factors that are naturally presented in the human eye such as the level of spherical aberration (SA) upon the IOL, light scattering at the diffractive steps or the depth of focus. The trifocal IOL is tested in-vitro in two eye models: the aberration-free ISO model, and a so called modified-ISO one that uses an artificial cornea with positive spherical SA in instead. The SA upon the IOL is measured with a Hartmann-Shack sensor and compared to the values of theoretical eye models. The results show, for large pupils, a notorious reduction of the energy efficiency of the far and near foci of the trifocal IOL due to two facts: the level of SA upon the IOL is larger than the value the lens is able to compensate for and there is significant light scattering at the diffractive steps. On the other hand, the energy efficiency of the intermediate focus for small pupils is enhanced by the contribution of the extended depth of focus of the near and far foci. Thus, while IOLs manufacturers tend to provide just the theoretical diffraction efficiency of the foci to show which would be the performance of the lens in terms of light distribution among the foci, our results put into evidence that this is better described by using the energy efficiency of the foci.

  8. Intraocular lens employed for cataract surgery

    International Nuclear Information System (INIS)

    The aim of this paper is to illustrate the techniques of cataract surgery with implantation of intraocular lenses and some physical properties of the used materials. The new technology, coupled with extensive experience and the studied cases, permits to increase the standardization and accuracy of the engravings, by reducing the use and handling of surgical instruments inside the eye. At present it is possible to replace the cataract with crystalline lenses based on biopolymers such as PMMA, silicone, acrylic hydrophilic and hydrophobic acrylic. These materials are increasingly able to replace the natural lens and to ensure the fully functional of the eye. The role of femtosecond lasers in cataract surgery, to assist or replace several aspects of the manual cataract surgery, are discussed.

  9. Mechanical properties of intra-ocular lenses

    Science.gov (United States)

    Ehrmann, Klaus; Kim, Eon; Parel, Jean-Marie

    2008-02-01

    Cataract surgery usually involves the replacement of the natural crystalline lens with a rigid or foldable intraocular lens to restore clear vision for the patient. While great efforts have been placed on optimising the shape and optical characteristics of IOLs, little is know about the mechanical properties of these devices and how they interact with the capsular bag once implanted. Mechanical properties measurements were performed on 8 of the most commonly implanted IOLs using a custom build micro tensometer. Measurement data will be presented for the stiffness of the haptic elements, the buckling resistance of foldable IOLs, the dynamic behaviour of the different lens materials and the axial compressibility. The biggest difference between the lens types was found between one-piece and 3-piece lenses with respect to the flexibility of the haptic elements

  10. Primary orbital neuroblastoma with intraocular extension

    Directory of Open Access Journals (Sweden)

    Muthukrishnan Vallinayagam

    2015-01-01

    Full Text Available Neuroblastoma is an undifferentiated malignancy of primitive neuroblasts. Neuroblastoma is among the most common solid tumors of childhood. Orbital neuroblastoma is typically a metastatic tumor. In this case report, we describe a 2-year-old child with a rapidly progressing orbital tumor. Computed tomography revealed an orbital mass lesion with extraocular and intraocular components. An incisional biopsy was done, and a histopathological examination showed features suggestive of neuroblastoma. Systemic workup including ultrasonography of the abdomen, chest roentgenogram, whole body computed tomography, and bone scintigraphy showed no evidence of systemic involvement. The diagnosis of primary orbital neuroblastoma was made, and the child was subjected to chemotherapy followed by rapid melting of the tumor. Neuroblastoma should be considered in the differential diagnosis of childhood orbital tumors.

  11. Intraocular lens employed for cataract surgery

    Science.gov (United States)

    Roszkowska, A. M.; Torrisi, L.

    2014-04-01

    The aim of this paper is to illustrate the techniques of cataract surgery with implantation of intraocular lenses and some physical properties of the used materials. The new technology, coupled with extensive experience and the studied cases, permits to increase the standardization and accuracy of the engravings, by reducing the use and handling of surgical instruments inside the eye. At present it is possible to replace the cataract with crystalline lenses based on biopolymers such as PMMA, silicone, acrylic hydrophilic and hydrophobic acrylic. These materials are increasingly able to replace the natural lens and to ensure the fully functional of the eye. The role of femtosecond lasers in cataract surgery, to assist or replace several aspects of the manual cataract surgery, are discussed.

  12. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  13. Intraocular pressure in Japanese diabetic patients

    Directory of Open Access Journals (Sweden)

    Matsuoka M

    2012-07-01

    Full Text Available Masato Matsuoka,1 Nahoko Ogata,2 Kayako Matsuyama,1 Tadanobu Yoshikawa,1 Kanji Takahashi31Department of Ophthalmology, Kansai Medical University, Takii Hospital, Osaka, 2Department of Ophthalmology, Nara Medical University, Nara, 3Department of Ophthalmology, Kansai Medical University, Hirakata Hospital, Osaka, JapanBackground: To determine whether the intraocular pressure (IOP in diabetic patients is significantly different from that in nondiabetic patients.Methods: The medical records of all patients who were initially examined in the Department of Ophthalmology, Kansai Medical University, Takii Hospital were reviewed. At the initial examination, patients had a detailed interview and underwent a comprehensive ophthalmic examinations. All patients were over 20 years of age and did not have glaucoma.Results: A total of 703 patients were evaluated. The mean (±standard error IOP of the diabetic patients was 15.5 ± 0.2 mmHg (n = 206, and was significantly higher than the 14.0 ± 0.1 mmHg (n = 497 in the nondiabetic patients (P < 0.0001. The IOP was negatively correlated with age (r = –0.202; P = 0.024 in the diabetic patients and was weakly but significantly correlated with the glycosylated hemoglobin (HbA1c level (r = 0.240; P = 0.015 in the group with diabetic retinopathy.Conclusion: The significantly higher IOP in diabetic patients and positive correlation of IOP with HbA1c levels in patients with diabetic retinopathy indicate that IOP in diabetic patients is higher, especially in those with poor control of diabetes.Keywords: diabetes mellitus, diabetic retinopathy, intraocular pressure, open-angle glaucoma

  14. Computational modeling of intraocular gas dynamics

    Science.gov (United States)

    Noohi, P.; Abdekhodaie, M. J.; Cheng, Y. L.

    2015-12-01

    The purpose of this study was to develop a computational model to simulate the dynamics of intraocular gas behavior in pneumatic retinopexy (PR) procedure. The presented model predicted intraocular gas volume at any time and determined the tolerance angle within which a patient can maneuver and still gas completely covers the tear(s). Computational fluid dynamics calculations were conducted to describe PR procedure. The geometrical model was constructed based on the rabbit and human eye dimensions. SF6 in the form of pure and diluted with air was considered as the injected gas. The presented results indicated that the composition of the injected gas affected the gas absorption rate and gas volume. After injection of pure SF6, the bubble expanded to 2.3 times of its initial volume during the first 23 h, but when diluted SF6 was used, no significant expansion was observed. Also, head positioning for the treatment of retinal tear influenced the rate of gas absorption. Moreover, the determined tolerance angle depended on the bubble and tear size. More bubble expansion and smaller retinal tear caused greater tolerance angle. For example, after 23 h, for the tear size of 2 mm the tolerance angle of using pure SF6 is 1.4 times more than that of using diluted SF6 with 80% air. Composition of the injected gas and conditions of the tear in PR may dramatically affect the gas absorption rate and gas volume. Quantifying these effects helps to predict the tolerance angle and improve treatment efficiency.

  15. Application of Foldable Intraocular Lens in Multiple Types of Cataract

    Institute of Scientific and Technical Information of China (English)

    Songtao Yuan; Qinghuai Liu; Qing Jiang; Nanrong Yuan

    2002-01-01

    Objective: To evaluate the clinical results of implantation of foldable intraocular lens inmultiple types of cataract.Methods: This retrospective study comprised 162 eyes of 148 patients undergoingphacoemulsification and implantation of foldable intraocular lens, some of whom under-went combined pars plana vitrectomy or trabeculectomy or silicone oil removal. Theperiod of follow-up was from 3 months to 17 months.Results: There is slight reaction postoperatively in all cases. The postoperative uncorrectedvisual acuites was from 0. 05 to 1.2, patient with 0.6 or above acuity were 70.98%. Aneodymium: YAG capsulotomy was required in 5 eyes. Posterior capsule ruptured in 1eyes, and a PMMA intraocular lens was implanted in ciliary sulcus. In one eye, a lenswas removed because of recurrence of retina detachment.Conclusions: The application of foldable intraocular lens in multiple types of cataract issafe, and there is a slight postoperative reaction. less complications , and fast visualacuity recovery.

  16. Patient acceptability of the Tecnis® multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Sood P

    2011-03-01

    Full Text Available Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anterior prolate IOL with a diffractive multifocal lens design. The design aims to minimize spherical aberration and improve range of focus. The purpose of this review is to assess patient acceptability of the Tecnis® multifocal intraocular lens.Keywords: Tecnis®, intraocular lens, multifocal, presbyopia 

  17. Artificial blood

    Directory of Open Access Journals (Sweden)

    Sarkar Suman

    2008-01-01

    Full Text Available Artificial blood is a product made to act as a substitute for red blood cells. While true blood serves many different functions, artificial blood is designed for the sole purpose of transporting oxygen and carbon dioxide throughout the body. Depending on the type of artificial blood, it can be produced in different ways using synthetic production, chemical isolation, or recombinant biochemical technology. Development of the first blood substitutes dates back to the early 1600s, and the search for the ideal blood substitute continues. Various manufacturers have products in clinical trials; however, no truly safe and effective artificial blood product is currently marketed. It is anticipated that when an artificial blood product is available, it will have annual sales of over $7.6 billion in the United States alone.

  18. Intraocular Gnathostomiasis: Report of a Case and Review of Literature

    OpenAIRE

    Pillai, Gopal S.; Kumar, Anil; Radhakrishnan, Natasha; Maniyelil, Jayasree; Shafi, Tufela; Dinesh, Kavitha R.; Karim, Shamsul

    2012-01-01

    Intraocular gnathostomiasis is a rare parasitic infection caused by the third-stage larvae of spiruroid nematode Gnanthostoma spp. seen mostly in tropical and subtropical regions. It is a food-borne zoonosis caused by ingestion of raw or undercooked freshwater fish, amphibians, reptiles, birds, and mammals, all of which are known to harbor advanced third-stage larvae of Gnanthostoma spp. To date, 74 cases of intraocular gnathostomiasis have been reported from 12 different countries. Only four...

  19. Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision

    OpenAIRE

    Ladan Espandar; Shameema Sikder; Majid Moshirfar

    2011-01-01

    Ladan Espandar1, Shameema Sikder2, Majid Moshirfar31Department of Ophthalmology, Tulane University, New Orleans, LA, USA; 2Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USA; 3John A Moran Eye Center, University of Utah, Salt Lake City, UT, USAAbstract: Intraocular lens development is driven by higher patient expectations for ideal visual outcomes. The recently US Food and Drug Administration-approved Softec HD™ lens is an aspheric, hydrophilic acrylic intraocular le...

  20. Patient acceptability of the Tecnis® multifocal intraocular lens

    OpenAIRE

    Woodward, Maria; Sood,Priyanka

    2011-01-01

    Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL) designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anter...

  1. Relation between intraocular pressure and size of transverse sinuses.

    Science.gov (United States)

    Kantarci, Mecit; Dane, Senol; Gumustekin, Kenan; Onbas, Omer; Alper, Fatih; Okur, Adnan; Aslankurt, Murat; Yazici, Ahmet Taylan

    2005-01-01

    There are asymmetries in the sizes of transverse sinus and intraocular pressure. The purpose of this study was to investigate possible relationships between the asymmetry of transverse sinuses in TOF MR venography and intraocular pressures of right and left eyes. In this study, subjects were 63 male and 42 female medical school students, aged 18-21 years (mean+/-SD; 19.72+/-0.67 years). Subjects with neurological and ophthalmologic disease, particularly dural sinus thrombosis, myopia, trauma and glaucoma, were excluded the study. Subjects were divided into five groups according to the magnitudes of the right- and left-transverse sinuses in MR venography results. There is a functional relation between intraocular pressures of the right and left eyes and asymmetry of the transverse sinus. If the transverse sinus on one side is larger and its venous drainage is greater, the intraocular pressure of the eye on this side is lower. It can be speculated that the transverse sinus size may be associated with pathogenesis of diseases with increased intraocular pressure such as glaucoma. We aim to determine the relation between the size and drainage of transverse sinuses in TOF MR venography and intraocular pressure in patients with open-angle glaucoma in our next study. PMID:15647949

  2. Relation between intraocular pressure and size of transverse sinuses

    Energy Technology Data Exchange (ETDEWEB)

    Kantarci, Mecit; Onbas, Omer; Alper, Fatih; Okur, Adnan [Atatuerk University, Department of Radiology, Medical Faculty, Erzurum (Turkey); Dane, Senol; Gumustekin, Kenan [Atatuerk University, Department of Physiology, Medical Faculty, Erzurum (Turkey); Aslankurt, Murat [Atatuerk University, Department of Ophtalmatology, Medical Faculty, Erzurum (Turkey); Yazici, Ahmet Taylan [Beyoglu Goez Egitim ve Arastirma Hastanesi, Istanbul (Turkey)

    2005-01-01

    There are asymmetries in the sizes of transverse sinus and intraocular pressure. The purpose of this study was to investigate possible relationships between the asymmetry of transverse sinuses in TOF MR venography and intraocular pressures of right and left eyes. In this study, subjects were 63 male and 42 female medical school students, aged 18-21 years (mean{+-}SD; 19.72{+-}0.67 years). Subjects with neurological and ophthalmologic disease, particularly dural sinus thrombosis, myopia, trauma and glaucoma, were excluded the study. Subjects were divided into five groups according to the magnitudes of the right- and left-transverse sinuses in MR venography results. There is a functional relation between intraocular pressures of the right and left eyes and asymmetry of the transverse sinus. If the transverse sinus on one side is larger and its venous drainage is greater, the intraocular pressure of the eye on this side is lower. It can be speculated that the transverse sinus size may be associated with pathogenesis of diseases with increased intraocular pressure such as glaucoma. We aim to determine the relation between the size and drainage of transverse sinuses in TOF MR venography and intraocular pressure in patients with open-angle glaucoma in our next study. (orig.)

  3. Artificial urushi.

    Science.gov (United States)

    Kobayashi, S; Uyama, H; Ikeda, R

    2001-11-19

    A new concept for the design and laccase-catalyzed preparation of "artificial urushi" from new urushiol analogues is described. The curing proceeded under mild reaction conditions to produce the very hard cross-linked film (artificial urushi) with a high gloss surface. A new cross-linkable polyphenol was synthesized by oxidative polymerization of cardanol, a phenol derivative from cashew-nut-shell liquid, by enzyme-related catalysts. The polyphenol was readily cured to produce the film (also artificial urushi) showing excellent dynamic viscoelasticity. PMID:11763444

  4. Artificial intelligence

    CERN Document Server

    Ennals, J R

    1987-01-01

    Artificial Intelligence: State of the Art Report is a two-part report consisting of the invited papers and the analysis. The editor first gives an introduction to the invited papers before presenting each paper and the analysis, and then concludes with the list of references related to the study. The invited papers explore the various aspects of artificial intelligence. The analysis part assesses the major advances in artificial intelligence and provides a balanced analysis of the state of the art in this field. The Bibliography compiles the most important published material on the subject of

  5. Primary Posterior Chamber Intraocular Lens Implantation in Traumatic Cataract With Posterior Capsule Breaks

    Institute of Scientific and Technical Information of China (English)

    YupingZou; WenhuiYang

    1995-01-01

    Background:In patients with incomplete posterior capsule support,posterior chamber intraocular lenses(PC-IOLs)were implanted with both haptics transs-cleral fixation.This causes more damage to the eye and may result in more com-plications,In patients with small posterior breaks,non-fixation or single haptic fixation may be adequate.Methods:Thiry-two consecutive patients of traumatic cataract with posterior capsule breaks caused by penetrating eye trauma were retospected.Posterior chamber intraocular lenses were implanted in all these patients with three tech-niques,ie,without fixation,with single haptic fixation and with both haptics fixation .The selection of the technique was based on the position and size of the posterior capsule.The follow-up period was 21days to 28months(mean,15.2months).Results:Intra-operative problems included ciliary body bleeding(Two patents,6.25%)and enlargement of posterior capsule breaks(2patients,6.25).Postoperative visual acuity was0.5or better(Corrected)in28case(87.5%)and 0.1-0.4in four patients(12.5%),Postoperative complications included hyphema(6eyes,18.8%),transient intraocular pressure elevation(6eyes,18.8%),transient hypotention(7eyes,21.8%).Postoperative IOL position were good except one case of IOL tilt.No pupillary capture or endophthalmitis was found.Conclusions:Not all PC-IOLs have to be fixed by two haptics.In patients with small posterior capsule breaks,PC-IOLmay not be fixed or fixed by only one haptics.Eye Science1995;11:140-142.

  6. Artificial Reefs

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — An artificial reef is a human-made underwater structure, typically built to promote marine life in areas with a generally featureless bottom, control erosion, block...

  7. A study of brachytherapy for intraocular tumor

    International Nuclear Information System (INIS)

    Our purpose of this study is to perform brachytherapy for intraocular tumor. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere. Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm. Maximum error is -11.3% and 0.8 mm, respectively. 7 figs, 2 tabs, 28 refs. (Author)

  8. Surgical management of intraocular lens dislocations

    Directory of Open Access Journals (Sweden)

    Adem Gul

    2015-10-01

    Full Text Available ABSTRACTPurpose:To report and compare the surgical, visual, and anatomical outcomes following treatment of dislocated intraocular lenses (IOLs.Methods:The medical records of 28 eyes of 28 patients were evaluated. Age, gender, pre-and postoperative best-corrected visual acuity (BCVA, surgical methods, and complications were recorded.Results:Pre-and postoperative BCVA ranged from counting fingers to 20/32 and from counting fingers to 20/25, respectively. Late-onset dislocations were the most frequently observed complication. The most frequent surgical method was IOL repositioning in 15 of 28 patients, followed by IOL exchange in 11 patients, and IOL removal in 2 patients. Only 1 patient required surgical re-intervention with IOL capture.Conclusions:Visual acuity improved following the use of either IOL repositioning or IOL exchange. No superiority of one method over the other was observed. In the present retrospective case series, management of dislocated IOLs with repositioning or exchange of the primary implant conferred comparable surgical and visual outcomes.

  9. The new factors defining variability of circadian’s rhythms of intraocular and perfusion pressure of glaucoma patients

    Directory of Open Access Journals (Sweden)

    N. A. Baranova

    2016-01-01

    Full Text Available Currently, the most scientifically based local risk and progressive factors are elevated levels of intraocular pressure and its instability during the day, caused by local hydromechanical disturbances. However, the other factors affecting the circadian changes of intraocular pressure levels are still evaluated. It was found that light is one of the most important factors affecting the intensity of the cyclical fluctuations of various biological processes, including, and fluctuations of intraocular pressure. At the same time, glaucoma can lead to a variety of sleep disorders, due to a mismatch between cycles «sleep-wake». One if this reason is the death of retinal ganglion cells and their axons. Such damage indirectly lead to a decrease in production of the pigment melanopsin, which is located in the retina. It is not involved in the visual process, but ensures the implementation of circadian rhythms «sleep-wake» and mediated suppression of epiphyseal melatonin. Most likely, melatonin plays a protective role in the occurrence and progression of glaucoma, protecting retinal cells against free radicals and has a direct impact on the intraocular pressure level. Several studies have shown that the circadian change in intraocular pressure levels, and in particular, its substantial reduction, is influenced by melatonin. In this regard, glaucoma is a disease in which the death of retinal cells, including producing melanopsin, a unique opportunity to study violations of cyclic rhythms. Melatonin acts on such established risk factors and progression of glaucoma as hypertension and diabetes. There are published results of the use of melatonin agonists in the experiment and clinical practice. So, in addition to local and systemic hypotensive action, normalizes sleep patients. Data about the melatonin’s effects on the direct and indirect reduction of intraocular pressure, neuroprotective effects and reducing symptoms of depression can

  10. Comparison of Trans-scleral Fixation of PMMA and Foldable Intraocular Lens in Children

    Institute of Scientific and Technical Information of China (English)

    Yuping Zou; Zhende Lin; Bo Feng; Shaozhen Li

    2001-01-01

    Purpose: To observe the difference of the effects of PMMA and foldable intraocular lenses (IOLs) trans-sclerally fixed in pediatric eyes. Methods: Thirty-two children (43 eyes) who had undergone trans-scleral fixation of IOL were retrospected, of whom 5 children were implanted PMMA IOL in both eyes, 6children were implanted PMMA IOL in one eye and foldable IOL in the other eye, 12children were implanted foldable IOL in one eye and 9 chilrden were implanted PMMA IOL in one eye. Mean age was 5.3 years ( range 2.5 ~ 12 years ). Twelve children had traumatic cataract and the others congenital cataract before lens extraction. Results: Foldable group (18 eyes ): Mean follow-up was 12.1 months. Visual acuity (VA): compared with the best corrected VA before IOL fixation, postoperative best corrected VA improved in 16 eyes, remained unchanged in 2 eyes. In 14 eyes, one or two stitches were needed to seal the incision. Complications: Severe anterior chamber reaction was seen in 3 eyes. Intraocular bleeding was found in 3 eyes. IOL decentration was detected in 1 eye. Iris capture of IOL was seen in one eye. PMMA group (25 eyes ):Mean follow-up was 20.3 months. Visual acuity (VA): compared with the best corrected VA before IOL fixation, postoperative best corrected VA improved in 19 eyes,remained unchanged in 5 eyes and got worse in one eye. In 24 eyes, one to three stitches were needed to seal the incision. Complications: Severe anterior chamber reaction was seen in 5 eyes. Intraocular bleeding was found in 4 eyes. IOL decentration was seen in one eye. Iris capture of IOL was seen in 3 eyes. Intraocular pressure elevated in one eye. Conclusion: Our study shows that trans-scleral fixation of IOL is a safe procedure in pediatric eyes. Foldable IOL showed similar effect compared with PMMA IOL in pediatric trans-scleral fixation. Eye Science 2001; 17:61 ~ 64.

  11. Bucket elevator

    OpenAIRE

    Sklenář, Adam

    2016-01-01

    The aim of this thesis is a design of a vertical bucket elevator which is to be used to transport cereal. The transport height is nineteen meters and transport capacity one hundred tons per hour. This thesis consists of a description of the vertical bucket elevator and its main parts which are mentioned in the introductory list. The thesis deals with functional and capacitive calculations, determining a drive and a tensioning device. Another calculation has the function of control a drive sha...

  12. [Intraocular Pressure Sensor Based on a Contact Lens].

    Science.gov (United States)

    Guo, Xuhong; Pet, Weihua; Yao, Zhaolin; Chen, Yuanfang; Hu, Xiaohui; Chen, Hongda; Zhu, Jingyuan; Wu, Huijuan

    2016-02-01

    Intraocular pressure detection has a great significance for understanding the status of eye health, prevention and treatment of diseases such as glaucoma. Traditional intraocular pressure detection needs to be held in the hospital. It is not only time-consuming to doctors and patients, but also difficult to achieve 24 hour-continuous detection. Microminiaturization of the intraocular pressure sensor and wearing it as a contact lens, which is convenient, comfortable and noninvasive, can solve this problem because the soft contact lens with an embedded micro fabricated strain gauge allows the measurement of changes in corneal curvature to correlate to variations of intraocular pressure. We fabricated a strain gauge using micro-electron mechanical systems, and integrated with the contact lens made of polydimethylsiloxane (PDMS) using injection molding. The experimental results showed that the sensitivity was 100. 7 µV/µm. When attached to the corneal surface, the average sensitivity of sensor response of intraocular pressure can be 125.8 µV/mm Hg under the ideal condition. PMID:27382734

  13. Effects of 2-alkynyladenosine derivatives on intraocular pressure in rabbits.

    Science.gov (United States)

    Konno, Takashi; Ohnuma, Shin-ya; Uemoto, Kazuhiro; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Endo, Kazuki; Hosokawa, Tomokazu; Nakahata, Norimichi

    2004-02-23

    We evaluated the activities of 2-alkynyladenosine derivatives, relatively selective adenosine A2 receptor agonists, in the intraocular pressure regulation in rabbits. An adenosine A2 receptor agonist 2-[p-(2-carboxyethyl)phenylethylamino]-5'-N-ethylcarboxamidoadenosine (CGS-21680) decreased intraocular pressure, while another A2 receptor agonist 2-(phenylamino)adenosine transiently increased it. The first group of 2-alkynyladenosine derivatives (1-hexyn-1-yl derivatives) caused a transient increase followed by decrease in intraocular pressure, while the second group (1-octyn-1-yl and 6-cyano-1-hexyn-1-yl derivatives) only decreased it. The second group is also effective in the ocular hypertensive models induced by water-loading and alpha-chymotrypsin. The outflow facility was increased by a 1-octyn-1-yl derivative. Both increase and decrease in intraocular pressure induced by 2-alkynyladenosine derivatives were inhibited by an adenosine A2 receptor antagonist 3,7-dimethyl-1-propargylxanthine, but not by an adenosine A1 receptor antagonist 8-cyclopentyl-1,3-dipropyl xanthine. These findings suggest that 2-alkynyladenosine derivatives may affect intraocular pressure via adenosine A2 receptor, and 2-alkynyladenosine derivative-induced ocular hypotension is due to the increase of outflow facility.

  14. Effects of 2-alkynyladenosine derivatives on intraocular pressure in rabbits.

    Science.gov (United States)

    Konno, Takashi; Ohnuma, Shin-ya; Uemoto, Kazuhiro; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Endo, Kazuki; Hosokawa, Tomokazu; Nakahata, Norimichi

    2004-02-23

    We evaluated the activities of 2-alkynyladenosine derivatives, relatively selective adenosine A2 receptor agonists, in the intraocular pressure regulation in rabbits. An adenosine A2 receptor agonist 2-[p-(2-carboxyethyl)phenylethylamino]-5'-N-ethylcarboxamidoadenosine (CGS-21680) decreased intraocular pressure, while another A2 receptor agonist 2-(phenylamino)adenosine transiently increased it. The first group of 2-alkynyladenosine derivatives (1-hexyn-1-yl derivatives) caused a transient increase followed by decrease in intraocular pressure, while the second group (1-octyn-1-yl and 6-cyano-1-hexyn-1-yl derivatives) only decreased it. The second group is also effective in the ocular hypertensive models induced by water-loading and alpha-chymotrypsin. The outflow facility was increased by a 1-octyn-1-yl derivative. Both increase and decrease in intraocular pressure induced by 2-alkynyladenosine derivatives were inhibited by an adenosine A2 receptor antagonist 3,7-dimethyl-1-propargylxanthine, but not by an adenosine A1 receptor antagonist 8-cyclopentyl-1,3-dipropyl xanthine. These findings suggest that 2-alkynyladenosine derivatives may affect intraocular pressure via adenosine A2 receptor, and 2-alkynyladenosine derivative-induced ocular hypotension is due to the increase of outflow facility. PMID:14985053

  15. [Intraocular Pressure Sensor Based on a Contact Lens].

    Science.gov (United States)

    Guo, Xuhong; Pet, Weihua; Yao, Zhaolin; Chen, Yuanfang; Hu, Xiaohui; Chen, Hongda; Zhu, Jingyuan; Wu, Huijuan

    2016-02-01

    Intraocular pressure detection has a great significance for understanding the status of eye health, prevention and treatment of diseases such as glaucoma. Traditional intraocular pressure detection needs to be held in the hospital. It is not only time-consuming to doctors and patients, but also difficult to achieve 24 hour-continuous detection. Microminiaturization of the intraocular pressure sensor and wearing it as a contact lens, which is convenient, comfortable and noninvasive, can solve this problem because the soft contact lens with an embedded micro fabricated strain gauge allows the measurement of changes in corneal curvature to correlate to variations of intraocular pressure. We fabricated a strain gauge using micro-electron mechanical systems, and integrated with the contact lens made of polydimethylsiloxane (PDMS) using injection molding. The experimental results showed that the sensitivity was 100. 7 µV/µm. When attached to the corneal surface, the average sensitivity of sensor response of intraocular pressure can be 125.8 µV/mm Hg under the ideal condition.

  16. Monocular Elevation Deficiency - Double Elevator Palsy

    Science.gov (United States)

    ... Español Condiciones Chinese Conditions Monocular Elevation Deficiency/ Double Elevator Palsy En Español Read in Chinese What is monocular elevation deficiency (Double Elevator Palsy)? Monocular Elevation Deficiency, also known by the ...

  17. Artificial intelligence

    International Nuclear Information System (INIS)

    A vivid example of the growing need for frontier physics experiments to make use of frontier technology is in the field of artificial intelligence and related themes. This was reflected in the second international workshop on 'Software Engineering, Artificial Intelligence and Expert Systems in High Energy and Nuclear Physics' which took place from 13-18 January at France Telecom's Agelonde site at La Londe des Maures, Provence. It was the second in a series, the first having been held at Lyon in 1990

  18. Artificial Intelligence

    CERN Document Server

    Warwick, Kevin

    2011-01-01

    if AI is outside your field, or you know something of the subject and would like to know more then Artificial Intelligence: The Basics is a brilliant primer.' - Nick Smith, Engineering and Technology Magazine November 2011 Artificial Intelligence: The Basics is a concise and cutting-edge introduction to the fast moving world of AI. The author Kevin Warwick, a pioneer in the field, examines issues of what it means to be man or machine and looks at advances in robotics which have blurred the boundaries. Topics covered include: how intelligence can be defined whether machines can 'think' sensory

  19. New trends in intraocular lens imaging

    Science.gov (United States)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the

  20. File list: Oth.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.50.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  1. File list: NoD.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.05.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  2. File list: Pol.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.20.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  3. File list: Pol.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.05.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  4. File list: InP.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Oth.20.AllAg.Lenses,_Intraocular mm9 Input control Others Lenses, Intraocular S...RX957681,SRX957691,SRX957693 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  5. File list: His.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Oth.10.AllAg.Lenses,_Intraocular mm9 Histone Others Lenses, Intraocular SRX9576...85,SRX957687,SRX957695,SRX957683 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  6. File list: NoD.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.10.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  7. File list: InP.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Oth.05.AllAg.Lenses,_Intraocular mm9 Input control Others Lenses, Intraocular S...RX957681,SRX957691,SRX957693 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  8. File list: Unc.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Oth.50.AllAg.Lenses,_Intraocular mm9 Unclassified Others Lenses, Intraocular SR...X1127448 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  9. File list: His.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Oth.20.AllAg.Lenses,_Intraocular mm9 Histone Others Lenses, Intraocular SRX9576...85,SRX957687,SRX957695,SRX957683 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  10. File list: Pol.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.50.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  11. File list: His.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Oth.50.AllAg.Lenses,_Intraocular mm9 Histone Others Lenses, Intraocular SRX9576...85,SRX957687,SRX957683,SRX957695 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  12. File list: Oth.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.05.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  13. File list: NoD.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.20.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  14. File list: Unc.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Oth.20.AllAg.Lenses,_Intraocular mm9 Unclassified Others Lenses, Intraocular SR...X1127448 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  15. File list: Oth.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.20.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  16. File list: NoD.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.50.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  17. File list: Unc.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Oth.05.AllAg.Lenses,_Intraocular mm9 Unclassified Others Lenses, Intraocular SR...X1127448 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  18. File list: Pol.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.10.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  19. File list: Oth.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.10.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  20. File list: InP.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Oth.10.AllAg.Lenses,_Intraocular mm9 Input control Others Lenses, Intraocular S...RX957681,SRX957691,SRX957693 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  1. Penetrating Scleral Injury with Intraocular Foreign Body. A Case Report

    Directory of Open Access Journals (Sweden)

    Anay Martínez Díaz

    2014-04-01

    Full Text Available Ocular trauma is a health problem in the world today and a common cause of visual impairment leading to severe sequelae and psychological disorders. The case of a 46-year-old male patient who attended the Ophthalmology emergency services of the Dr. Gustavo Aldereguía Lima University General Hospital of Cienfuegos, recounting that while hammering iron on iron he felt that something entered his right eye, is presented. He suffered from pain, tearing, red eye and blurred vision. A penetrating scleral injury with an intraocular foreign body was diagnosed. Its study was conducted through biomicroscopy, orbital x-ray and ocular ultrasound. Surgical treatment by extracapsular lens extraction with intraocular lens implantation was performed using Blumenthal technique and pars plana approach for removal of the intraocular foreign body.

  2. Epithelial Downgrowth after Intraocular Surgery Treated with Intracameral 5-Fluorouracil

    Directory of Open Access Journals (Sweden)

    Nina Ni

    2015-01-01

    Full Text Available Purpose. To present the clinical and histopathologic correlation of two cases of epithelial downgrowth (EDG after prior intraocular surgery. Methods. Observational case reports. Results. We present two cases of EDG occurring after intraocular surgery. In both cases, after two anterior chamber injections of 5-fluorouracil (5FU, the area of EDG initially regressed. In Case 1, a limited area of EDG eventually recurred, and penetrating keratoplasty with cryotherapy was curative. In Case 2, subsequent corneal edema required Descemet-stripping automated endothelial keratoplasty, and the patient remained clinically free of EDG without further treatment. Conclusion. Intracameral 5FU may have a role in the treatment of EDG after intraocular surgery, though its precise utilization and impact remain to be defined.

  3. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Science.gov (United States)

    Faria, Mun Yueh; Ferreira, Nuno Pinto; Pinto, Joana Medeiros; Sousa, David Cordeiro; Leal, Ines; Neto, Eliana; Marques-Neves, Carlos

    2016-01-01

    Background Nowadays, dislocated intraocular lenses (IOLs) and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL) are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL. Methods This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth. Results The mean follow-up was 23 months (range: 6–48 months). The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1) retinal detachment was found in one patient, 2) corneal edema was found in three patients, 3) high intraocular pressure was observed in twelve patients, 4) subluxation of the IOL was observed in one patient, and 5) macular edema was found in three eyes. Conclusion The results demonstrate that retropupillary ICIOL is an easy and effective method for the correction of aphakia in patients not receiving capsule support. The safety of this procedure must be interpreted in the context

  4. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-08-01

    Full Text Available Mun Yueh Faria,1–3 Nuno Pinto Ferreira,1–3 Joana Medeiros Pinto,1–3 David Cordeiro Sousa,1–3 Ines Leal,1–3 Eliana Neto,1–3 Carlos Marques-Neves1–3 1Centro de Estudos da Visão, Universidade de Lisboa, 2Department of Ophthalmology, Hospital de Santa Maria, 3Faculty of Medicine, University of Lisbon, Lisbon, Portugal Background: Nowadays, dislocated intraocular lenses (IOLs and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL.Methods: This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth.Results: The mean follow-up was 23 months (range: 6–48 months. The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1 retinal detachment was found in one patient, 2 corneal edema was found in three patients, 3 high intraocular pressure was observed in

  5. Abnormal increase of intraocular pressure in fellow eye after severe ocular trauma

    Science.gov (United States)

    Vaajanen, Anu; Tuulonen, Anja

    2016-01-01

    Abstract Background: An ocular injury can lead to secondary glaucoma in the traumatized eye in 3% to 20% of cases. Literature on the risk of developing elevated intraocular pressure in the nontraumatized fellow eye is scant. Clinicians treating ocular traumas should also bear in mind sympathetic ophthalmia, a rare bilateral granulomatous panuveitis following accidental or surgical trauma to 1 eye. Case report: We report a case of high-pressure glaucoma of the fellow eye without any signs of uveitis. The left eye of a 24-year-old man was injured in an inadvertent movement during a free-time table-tennis match. The eye was severely crushed, leading to blindness. His right eye developed medically uncontrolled high-pressure glaucoma only 1 month after the injury. Conclusion: To the best of our knowledge, there are no previous reports of post-traumatic glaucoma in the nontraumatized eye after open-globe injury. PMID:27495058

  6. Polyvinylidene Flouride Polymer Applied in an Intraocular Pressure Sensor

    Science.gov (United States)

    González Morán, Carlos Omar; González Ballesteros, Rubén; Rodríguez Guzmán, Maria Dolores Alicia; Suaste Gómez, Ernesto

    2005-06-01

    An indentation intraocular pressure sensor (IIOPS) was designed and manufactured. It is based on piezoelectric polyvinylidene fluoride (PVDF) films. This sensor will help in the detection and diagnosis of intraocular pressure (IOP) in eye diseases like glaucoma. The pressure in the normal aqueous and vitreous phases is, on average, 15.5 mmHg and up of 21 mmHg when glaucoma exists. The proposed IIOPS offers a measurement range from 10-29 mmHg with a resolution of 1 mmHg and an accuracy of ± 0.025.

  7. Comparison of shape recovery ratios in various intraocular lens haptics.

    Science.gov (United States)

    Kimura, W; Kimura, T; Sawada, T; Kikuchi, T; Toda, H; Yamada, Y; Nagai, H

    1992-11-01

    Since understanding the mechanical properties of intraocular lens (IOL) haptic materials can minimize decentration after surgery, we have examined shape recovery ratios of various intraocular lens haptics (polypropylene [PP], polyvinylidene fluoride [PVDF], extruded poly(methyl methacrylate) [PMMA]) currently on the market under conditions that approximate clinical use. The results using various Ascon lens-holding forceps and compression tests, during which the lenses were held in a cylindrical holder for seven days, one month, and three months, indicated that PVDF haptics had better shape recovery capability than PP and extruded three-piece PMMA haptics.

  8. Development and experimental verification of an intraocular scattering model

    Science.gov (United States)

    Jiang, Chong-Jhih; Jhong, Tian-Siang; Chen, Yi-Chun; Sun, Ching-Cherng

    2011-10-01

    An intraocular scattering model was constructed in human eye model and experimentally verified. According to the biometric data, the volumetric scattering in crystalline lens and diffusion at retina fundus were developed. The scattering parameters of cornea, including particle size and obscuration ratio, were varied to make the veiling luminance of the eye model matching the CIE disability glare general formula. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated and compared with that of transparent lenses. The MTF of the intraocular scattering model showed nice correspondence with the data measured by a double-pass experiment.

  9. Artificial sweeteners

    DEFF Research Database (Denmark)

    Raben, Anne Birgitte; Richelsen, Bjørn

    2012-01-01

    Artificial sweeteners can be a helpful tool to reduce energy intake and body weight and thereby risk for diabetes and cardiovascular diseases (CVD). Considering the prevailing diabesity (obesity and diabetes) epidemic, this can, therefore, be an important alternative to natural, calorie-containin...

  10. Intraocular lens alignment from an en face optical coherence tomography image Purkinje-like method

    Science.gov (United States)

    Sun, Mengchan; de Castro, Alberto; Ortiz, Sergio; Perez-Merino, Pablo; Birkenfeld, Judith; Marcos, Susana

    2014-06-01

    Measurement of intraocular lens (IOL) alignment implanted in patients in cataract surgery is important to understand their optical performance. We present a method to estimate tilt and decentration of IOLs based on optical coherence tomography (OCT) images. En face OCT images show Purkinje-like images that correspond to the specular reflections from the corneal and IOL surfaces. Unlike in standard Purkinje-imaging, the tomographic nature of OCT allows unequivocal association of the reflection with the corresponding surface. The locations of the Purkinje-like images are linear combinations of IOL tilt, IOL decentration, and eye rotation. The weighting coefficients depend on the individual anterior segment geometry, obtained from the same OCT datasets. The methodology was demonstrated on an artificial model eye with set amounts of lens tilt and decentration and five pseudophakic eyes. Measured tilt and decentration in the artificial eye differed by 3.7% and 0.9%, respectively, from nominal values. In patients, average IOL tilt and decentration from Purkinje were 3.30±4.68 deg and 0.16±0.16 mm, respectively, and differed on average by 0.5 deg and 0.09 mm, respectively, from direct measurements on distortion-corrected OCT images. Purkinje-based methodology from anterior segment en face OCT imaging provided, therefore, reliable measurements of IOL tilt and decentration.

  11. Artificial Intelligence.

    Science.gov (United States)

    Lawrence, David R; Palacios-González, César; Harris, John

    2016-04-01

    It seems natural to think that the same prudential and ethical reasons for mutual respect and tolerance that one has vis-à-vis other human persons would hold toward newly encountered paradigmatic but nonhuman biological persons. One also tends to think that they would have similar reasons for treating we humans as creatures that count morally in our own right. This line of thought transcends biological boundaries-namely, with regard to artificially (super)intelligent persons-but is this a safe assumption? The issue concerns ultimate moral significance: the significance possessed by human persons, persons from other planets, and hypothetical nonorganic persons in the form of artificial intelligence (AI). This article investigates why our possible relations to AI persons could be more complicated than they first might appear, given that they might possess a radically different nature to us, to the point that civilized or peaceful coexistence in a determinate geographical space could be impossible to achieve.

  12. Controversies in intraocular lens implantation in pediatric uveitis.

    Science.gov (United States)

    Phatak, Sumita; Lowder, Careen; Pavesio, Carlos

    2016-12-01

    Cataract is one of the most common and visually debilitating complications of pediatric uveitis. It develops as a consequence of chronic inflammation and steroid use and is seen most often in juvenile idiopathic arthritis (JIA)-associated uveitis. Cataract extraction with intraocular lens (IOL) insertion has been carried out with a measure of success in non-uveitic pediatric eyes, but in cases of uveitis, multiple factors affect the final outcome. Chronic inflammation and its sequelae such as band keratopathy, posterior synechiae, and cyclitic membranes make surgical intervention more challenging and outcome less certain. Postoperative complications like increased inflammation, glaucoma, posterior capsular opacification, retrolental membranes, and hypotony may compromise the visual outcome. Early refractive correction is imperative in pediatric eyes to prevent amblyopia. The use of contact lenses and intraocular lenses in pediatric uveitic eyes were fraught with complications in the past. Surgical interventions such as vitreo-lensectomy followed by contact lens fitting and small incision cataract surgery followed by different types of intraocular lenses have been utilized, and many reports have been published, albeit in small patient groups. This review analyzes and discusses the existing literature on intraocular lens implantation in cases of pediatric uveitic cataract surgery. PMID:27009616

  13. Effect of chymase on intraocular pressure in rabbits.

    Science.gov (United States)

    Konno, Takashi; Maruichi, Midori; Takai, Shinji; Oku, Hidehiro; Sugiyama, Tetsuya; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Ikeda, Tsunehiko; Miyazaki, Mizuo

    2005-11-01

    Chymase is a chymotrypsin-like serine protease that is stored exclusively in the secretory granules of mast cells and converts big endothelins to endothelin-1 (1-31). The aim of this study was to evaluate the effect of chymase on intraocular pressure in rabbits. Chymase injection (3 and 10 mU) resulted in a trend toward increased intraocular pressure and a significant increase in intraocular pressure at a dose of 10 mU compared with the control. A specific chymase inhibitor, Suc-Val-Pro-Phe(P)(OPh)(2), attenuated the ocular hypertension induced by chymase. Endothelin-1 (1-31) also caused ocular hypertension, which was inhibited by a selective endothelin ET(A) receptor antagonist, cyclo(D-Asp-Pro-D-Val-Leu-D-Trp) (BQ-123). Moreover, chymase-induced ocular hypertension was inhibited by BQ-123. These results suggest that chymase influences the regulation of intraocular pressure, and it is likely that the formation of endothelin-1 (1-31) and subsequent activation of endothelin ET(A) receptors are involved in the development of ocular hypertension induced by chymase.

  14. Intraocular inflammation following endotamponade with high-density silicone oil.

    NARCIS (Netherlands)

    Theelen, T.; Tilanus, M.A.D.; Klevering, B.J.

    2004-01-01

    BACKGROUND: The use of a mixture of silicone oil and partially fluorinated alkanes (high-density silicone oil) has recently been suggested as intraocular tamponade in complicated retinal detachment of the inferior quadrants. We describe a series of patients who developed a clinical picture resemblin

  15. Hematoporphyrin derivative photoradiation therapy for the treatment of intraocular tumors

    International Nuclear Information System (INIS)

    Hematoporphyrin derivative (HpD) photoradiation therapy (PRT) is currently being examined for the treatment of intraocular tumors (retinoblastoma and uveal melanoma). HpD is preferentially retained in malignant tissue and tumorcidal action can be induced when HpD is activated with visible red light. Preclinical studies have been conducted using pigmented rabbits having transplanted intraocular tumors. A dye laser system has been used to generate red light (630 nm) for localized irradiation of ocular tissue following I.V. administration of HpD. The authors have previously reported that acute toxicity to normal retina (in the form of retinal necrosis) can be induced by HpD PRT, and that this damage can be limited to the treatment field. The results of current preclinical studies related to long term ocular toxicity, HpD distribution in ocular tissue and intraocular tumor tissue response following HpD PRT are presented. In addition, initial clinical results of intraocular HpD PRT are described

  16. Combined aniridic intraocular lens implantation and vitreoretinal surgery

    Science.gov (United States)

    Mehta, Hijab; Jayadev, Chaitra; Natarajan, S

    2007-01-01

    A 45-year-old man presented with post-traumatic aniridia. We describe the combined surgery done to treat both aniridia and epiretinal membrane simultaneously. A combined aniridia intraocular lens and vitreoretinal surgery was done. The case report highlights the advantage of combined surgery in terms of cost factor and surgical time. PMID:17699956

  17. Combined aniridic intraocular lens implantation and vitreoretinal surgery

    OpenAIRE

    Mehta Hitendra; Mehta Hijab; Jayadev Chaitra; Natarajan S

    2007-01-01

    A 45-year-old man presented with post-traumatic aniridia. We describe the combined surgery done to treat both aniridia and epiretinal membrane simultaneously. A combined aniridia intraocular lens and vitreoretinal surgery was done. The case report highlights the advantage of combined surgery in terms of cost factor and surgical time.

  18. Method for in vitro assessment of straylight from intraocular lenses

    NARCIS (Netherlands)

    Łabuz, Grzegorz; Vargas-Martín, Fernando; van den Berg, Thomas J T P; López-Gil, Norberto

    2015-01-01

    Ocular straylight has been measured by means of psychophysical methods over the years. This approach gives a functional parameter yielding a straight comparison with optically defined light scattering, and the point-spread-function. This is of particular importance when the effect of intraocular len

  19. Development of a ciliary muscle-driven accommodating intraocular lens

    NARCIS (Netherlands)

    Hermans, Erik A.; Terwee, Thom T.; Koopmans, Steven A.; Dubbelman, Michiel; van der Heijde, Rob G. L.; Heethaar, Rob M.

    2008-01-01

    PURPOSE: To develop a ciliary muscle-driven accommodating intraocular lens (IOL) that has a large and predictable range of variable power as a step toward spectacle independence. SETTING: Department of Physics and Medical Technology, VU University Medical Center, Amsterdam, The Netherlands. METHODS:

  20. Effect of chymase on intraocular pressure in rabbits.

    Science.gov (United States)

    Konno, Takashi; Maruichi, Midori; Takai, Shinji; Oku, Hidehiro; Sugiyama, Tetsuya; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Ikeda, Tsunehiko; Miyazaki, Mizuo

    2005-11-01

    Chymase is a chymotrypsin-like serine protease that is stored exclusively in the secretory granules of mast cells and converts big endothelins to endothelin-1 (1-31). The aim of this study was to evaluate the effect of chymase on intraocular pressure in rabbits. Chymase injection (3 and 10 mU) resulted in a trend toward increased intraocular pressure and a significant increase in intraocular pressure at a dose of 10 mU compared with the control. A specific chymase inhibitor, Suc-Val-Pro-Phe(P)(OPh)(2), attenuated the ocular hypertension induced by chymase. Endothelin-1 (1-31) also caused ocular hypertension, which was inhibited by a selective endothelin ET(A) receptor antagonist, cyclo(D-Asp-Pro-D-Val-Leu-D-Trp) (BQ-123). Moreover, chymase-induced ocular hypertension was inhibited by BQ-123. These results suggest that chymase influences the regulation of intraocular pressure, and it is likely that the formation of endothelin-1 (1-31) and subsequent activation of endothelin ET(A) receptors are involved in the development of ocular hypertension induced by chymase. PMID:16253233

  1. Impact factors on intraocular pressure measurements in healthy subjects.

    NARCIS (Netherlands)

    Theelen, T.; Meulendijks, C.F.M.; Geurts, D.; Leeuwen, A.M. van; Voet, N.B.; Deutman, A.F.

    2004-01-01

    AIM: To evaluate whether intraocular pressure (IOP) calculation by applanation tonometry is determined more essentially by the subject's neck position or by neck constriction. METHODS: 23 right eyes of 23 healthy subjects (12 male, 11 female) were included. IOP was measured by applanation tonometry

  2. NEW MATERIAL FOR LOW-COST INTRAOCULAR LENSES

    NARCIS (Netherlands)

    JONGEBLOED, WL; VANDERVEEN, G; KALICHARAN, D; VANANDEL, MV; BARTMAN, G; WORST, JGF

    1994-01-01

    A UV-hardening lacquer material based on polyurethane, used in Philips compact disc lens systems, was tested as suitable material for low-cost intraocular lenses (IOLs). A slightly changed composition (code number I-0.5A) came out as the best and was subsequenly tested, with reference to poly(methyl

  3. Combined aniridic intraocular lens implantation and vitreoretinal surgery

    Directory of Open Access Journals (Sweden)

    Mehta Hitendra

    2007-01-01

    Full Text Available A 45-year-old man presented with post-traumatic aniridia. We describe the combined surgery done to treat both aniridia and epiretinal membrane simultaneously. A combined aniridia intraocular lens and vitreoretinal surgery was done. The case report highlights the advantage of combined surgery in terms of cost factor and surgical time.

  4. Microscopic and spectroscopic investigation of an explanted opacified intraocular lens

    Energy Technology Data Exchange (ETDEWEB)

    Simon, V., E-mail: viosimon@phys.ubbcluj.ro [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Radu, T.; Vulpoi, A. [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Rosca, C. [Optilens Clinic of Ophthalmology, 400604 Cluj-Napoca (Romania); Eniu, D. [Iuliu Haţieganu University of Medicine and Pharmacy, Department of Molecular Sciences, 400349 Cluj-Napoca (Romania)

    2015-01-15

    Highlights: • Changes on intraocular lens (IOL) surface after implantation. • Partial opacification of IOL central area. • Elemental composition on IOL surface prior to and after implantation. • First XPS depth profiling examination of the opacifying deposits. • Cell-mediated hydroxyapatite structuring. - Abstract: The investigated polymethylmethacrylate intraocular lens explanted an year after implantation presented a fine granularity consisting of ring-like grains of about 15 μm in diameter. In order to evidence the changes occurred on intraocular lens relative to morphology, elemental composition and atomic environments, microscopic and spectroscopic analyses were carried out using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), energy-dispersive X-ray (EDS), and X-ray photoelectron (XPS) spectroscopies. The results revealed that the grains contain hydroxyapatite mineral phase. A protein layer covers the lens both in opacified and transparent zones. The amide II band is like in basal epithelial cells. The shape and size of the grains, and the XPS depth profiling results indicate the possibility of a cell-mediated process involving lens epithelial cells which fagocitated apoptotic epithelial cells, and in which the debris derived from cell necrosis were calcified. To the best of our knowledge, this is the first investigation on explanted intraocular lenses using XPS depth profiling in order to examine the inside of the opacifying deposits.

  5. Liquid-crystal intraocular adaptive lens with wireless control

    NARCIS (Netherlands)

    Simonov, A.N.; Vdovine, G.V.; Loktev, M.

    2007-01-01

    We present a prototype of an adaptive intraocular lens based on a modal liquid-crystal spatial phase modulator with wireless control. The modal corrector consists of a nematic liquid-crystal layer sandwiched between two glass substrates with transparent low- and high-ohmic electrodes, respectively.

  6. Controversies in intraocular lens implantation in pediatric uveitis.

    Science.gov (United States)

    Phatak, Sumita; Lowder, Careen; Pavesio, Carlos

    2016-12-01

    Cataract is one of the most common and visually debilitating complications of pediatric uveitis. It develops as a consequence of chronic inflammation and steroid use and is seen most often in juvenile idiopathic arthritis (JIA)-associated uveitis. Cataract extraction with intraocular lens (IOL) insertion has been carried out with a measure of success in non-uveitic pediatric eyes, but in cases of uveitis, multiple factors affect the final outcome. Chronic inflammation and its sequelae such as band keratopathy, posterior synechiae, and cyclitic membranes make surgical intervention more challenging and outcome less certain. Postoperative complications like increased inflammation, glaucoma, posterior capsular opacification, retrolental membranes, and hypotony may compromise the visual outcome. Early refractive correction is imperative in pediatric eyes to prevent amblyopia. The use of contact lenses and intraocular lenses in pediatric uveitic eyes were fraught with complications in the past. Surgical interventions such as vitreo-lensectomy followed by contact lens fitting and small incision cataract surgery followed by different types of intraocular lenses have been utilized, and many reports have been published, albeit in small patient groups. This review analyzes and discusses the existing literature on intraocular lens implantation in cases of pediatric uveitic cataract surgery.

  7. Artificial intelligence

    OpenAIRE

    Duda, Antonín

    2009-01-01

    Abstract : Issue of this work is to acquaint the reader with the history of artificial inteligence, esspecialy branch of chess computing. Main attention is given to progress from fifties to the present. The work also deals with fighting chess programs against each other, and against human opponents. The greatest attention is focused on 1997 and duel Garry Kasparov against chess program Deep Blue. The work is divided into chapters according to chronological order.

  8. Artificial vision.

    Science.gov (United States)

    Zarbin, M; Montemagno, C; Leary, J; Ritch, R

    2011-09-01

    A number treatment options are emerging for patients with retinal degenerative disease, including gene therapy, trophic factor therapy, visual cycle inhibitors (e.g., for patients with Stargardt disease and allied conditions), and cell transplantation. A radically different approach, which will augment but not replace these options, is termed neural prosthetics ("artificial vision"). Although rewiring of inner retinal circuits and inner retinal neuronal degeneration occur in association with photoreceptor degeneration in retinitis pigmentosa (RP), it is possible to create visually useful percepts by stimulating retinal ganglion cells electrically. This fact has lead to the development of techniques to induce photosensitivity in cells that are not light sensitive normally as well as to the development of the bionic retina. Advances in artificial vision continue at a robust pace. These advances are based on the use of molecular engineering and nanotechnology to render cells light-sensitive, to target ion channels to the appropriate cell type (e.g., bipolar cell) and/or cell region (e.g., dendritic tree vs. soma), and on sophisticated image processing algorithms that take advantage of our knowledge of signal processing in the retina. Combined with advances in gene therapy, pathway-based therapy, and cell-based therapy, "artificial vision" technologies create a powerful armamentarium with which ophthalmologists will be able to treat blindness in patients who have a variety of degenerative retinal diseases.

  9. Effect of alpha-2-agonist premedication on intraocular pressure after selective laser trabeculoplasty

    Directory of Open Access Journals (Sweden)

    Julius T Oatts

    2015-01-01

    Full Text Available Aim: To determine the effect of alpha-2-agonist (AA premedication (PM on intraocular pressure (IOP following selective laser trabeculoplasty (SLT. Methods: Retrospective cohort study of all patients undergoing 360° SLT at an institution with two prevalent practice patterns consisting of SLT performed with PM and without premedication (NPM with AA. The association between pre- and post-operative IOP was evaluated using a linear regression model in 49 (59% PM and 34 (41% NPM eyes. Results: The prevalence of IOP elevations up to 5 mmHg 1 h postoperatively was similar in both groups, occurring in 18% of PM and in 15% of NPM. Elevations above 5 mmHg were seen in 4% of PM and 8% of NPM (P = 0.732. After correcting for age, gender, diagnosis, number of medications, and preoperative IOP, the presence or absence of AA PM had no significant association with any postoperative IOP (P > 0.5. Conclusion: The practice of using AAs before SLT and measuring IOP at 1 h has not been validated yet adds to expenses and workflow burden. Our retrospective study showed no significant correlation between PM and postoperative or longer-term IOP. IOP at 1 h should be measured in patients who cannot tolerate transient pressure elevations. Further studies are needed to elucidate this relationship.

  10. Comparison of a new-generation sectorial addition multifocal intraocular lens and a diffractive apodized multifocal intraocular lens.

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Velthoven, M. van; Meulen, I. van der; Nieuwendaal, C.; Mourits, M.; Lapid-Gortzak, R.

    2012-01-01

    PURPOSE: To compare visual, refractive, and satisfactory outcomes between a new-generation sectorial addition multifocal intraocular lens (IOL) (Lentis Mplus LS-312; study group) and a diffractive apodized multifocal IOL (Restor SN6AD1; control group). SETTING: Private practice, Driebergen, and Depa

  11. 港珠澳大桥岛隧工程东西人工岛精密跨海高程传递测量%Precision sea- crossing elevation transfer survey between east and west artificial islands for Hongkong- Zhuhai- Macao Bridge

    Institute of Scientific and Technical Information of China (English)

    成益品; 张超

    2016-01-01

    以港珠澳大桥岛隧工程东、西人工岛之间精密高程传递测量为例,介绍经纬仪倾角法在精密高程传递测量的网点设计、觇板制作、外业观测、精度分析等各环节,制定出消除或减弱影响海上测量精度的细则。经工程实践验证,该方法可以达到二等跨河水准的精度,满足长距离精密跨海高程传递测量的需要。%Based on the precision elevation transfer survey between the east and west artificial islands for Hongkong-zhuhai-Macao Bridge, the paper introduces the theodolite angle method in precise elevation transfer measurement network design, sighting board production, field observation and precision analysis. Detailed rules were worked out for the elimination or weakening of factors influencing the precision of offshore survey. The engineering practice shows that this method can reach second order river crossing leveling accuracy and meet the needs of the long distance cross sea elevation transmission measurement.

  12. Experimental study on cyclosporine A drug delivery system in prevention of posterior capsule opacification after intraocular lens implantation in rabbits

    Institute of Scientific and Technical Information of China (English)

    Pei Cheng; Sun Naixue

    2008-01-01

    Objective To study the effect of cyclosporine A drug delivery system (CsA-DDS) on the prevention of posterior capsule opacification (PCO) after experimental intraocular lens implantation in rabbit eyes. Methods Twenty healthy New Zealand white rabbits, whose left eyes and right eyes were used respectively as experiment eyes and controls, were subjected to extracapsular lens extraction and artificial lens implantation. During the operation, CsA-DDS with poly (lactideco-glycolide) as carriers or empty DDS was implanted in the capsular bag for the experimental eyes and controls respectively. After the operation, anterior chamber reaction, intraocular pressure (IOP) and CsA concentration were monitored and twelve weeks after the operation, the eyes were extracted for histopathological and morphological examinations. Results There were no differences between the two groups in conjunctival congestion,IOP change and anterior chamber reaction. PCO was less severe in the experimental eyes than in the controls. Light microscopy revealed that posterior capsular membrane in the experimental eyes was slick, with no obvious proliferation,whereas in the controls, there were lens epithelial cell proliferation and cortex regeneration of different degrees.Morphological examination with electron microscope showed that in the experimental eyes, lens epithelial cells did not function actively and apoptosis occurred, whereas in the controls, epithelial cells presented active function. No marked ultrastructural changes were found in either group. Conclusion Cs-DDS can inhibit PCO after intraocular lens implantation in rabbit eyes and does not have toxic effects on the surrounding ocular tissues. Therefore, it has a good potential for clinical use in prevention of PCO.

  13. Impact of the Topical Ophthalmic Corticosteroid Loteprednol Etabonate on Intraocular Pressure.

    Science.gov (United States)

    Sheppard, John D; Comstock, Timothy L; Cavet, Megan E

    2016-04-01

    Corticosteroids are a mainstay therapeutic option for the treatment of ocular inflammation. However, safety remains a concern for clinicians, particularly with long-term use. Though highly effective at suppressing inflammatory and allergic responses, topical ophthalmic corticosteroids carry an inherent risk of side effects, including elevated intraocular pressure (IOP), a risk factor for the development of glaucoma. The corticosteroid loteprednol etabonate (LE) contains an ester rather than a ketone at the C-20 position, minimizing the potential for side effects, including IOP elevation. In early pivotal clinical trials of LE ophthalmic suspension for conjunctivitis (allergic, giant papillary), anterior uveitis, and post-operative inflammation, LE had minimal impact on IOP over short-term (gel, an ointment, and a suspension of LE in combination with tobramycin-have become commercially available. Multiple studies evaluating the safety and efficacy of LE for inflammatory conditions have been reported, including those requiring longer-term treatment such as photorefractive keratectomy, corneal transplantation, and dry eye disease. We review the available published data on the effect of LE on IOP and report on the cumulative incidence of clinically significant IOP elevations (≥10 mm Hg from baseline) with short-term and long-term LE use. In all studies, LE consistently demonstrated a low propensity to elevate IOP, regardless of formulation, dosage regimen, or treatment duration, including in known steroid responders. The cumulative proportion of patients exhibiting clinically significant IOP increases was 0.8% (14/1725 subjects) in studies evaluating short-term LE treatment and 1.5% (21/1386 subjects) in long-term studies. Furthermore, use of LE was associated with significantly lower rates of IOP elevation ≥10 mm Hg as compared to prednisolone acetate or dexamethasone (when used in combination with tobramycin). The cumulative data to date substantiates a

  14. Gauge Transconjunctival Sutureless Vitrectomy in Eyes with Posteriorly Dislocated Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Hüseyin Dündar

    2013-04-01

    Full Text Available Pur po se: To evaluate the efficacy and safety of 23-gauge (23G pars plana vitrectomy (PPV in dislocated intraocular lens (IOL cases: In early- and late-term follow-up. Ma te ri al and Met hod: In this retrospective study, the medical records of 17 patients who underwent 23 G PPV treatment for dislocated IOL between January 2009 and June 2011 were analyzed. Detailed ophthalmologic examination was performed in all patients; intraoperative and postoperative complications were recorded. Re sults: In this study, mean follow-up time was 9.0 (4-22 months and mean age was 60.8 (8-82 years. Mean time after cataract surgery was variable (mean of 28.3 (0-80 months. Four patients had trauma history, five patients had pseudoexfoliation syndrome, and two patients had pathologic myopia. Dislocated IOL was placed into the sulcus in nine patients (52.9%. In two cases (11.7%, the IOLs were removed, and the patients were left aphakic. In two cases out of other 6 (11.7%, the dislocated IOL was changed with scleral fixation lens, whereas in the other four cases (23.5%, IOL was changed with iris claw lens. One patient (5.8% remained at the same level of vision, while twelve (70.5% cases increased two or more lines in BCVA. The vision was decreased in two cases. Intraocular pressure elevation controlled by medication was observed in one case. For two days, hypotony was observed in one patient. Dis cus si on: 23 G PPV technique is an effective and safe method for removing and repositioning of dislocated IOL in the vitreous. (Turk J Ophthalmol 2013; 43: 99-102

  15. Intraocular lens exchange-removing the optic intact

    Science.gov (United States)

    Lee, Matthew Hao; Webster, Diane Lesley

    2016-01-01

    Current practice for intraocular lens (IOL) exchange is to cut the optic of the posterior chamber intraocular lens (PCIOL) prior to removing it. Great care must be taken during this maneuver to avoid a posterior capsular tear. Removing the haptics from the fibrosed capsule can also be hazardous, as it may result in zonular stress and dehiscence. A technique is described for performing foldable (one-piece acrylic) IOL removal without cutting the optic. Careful visco-dissection of the haptics with a low viscosity ophthalmic viscosurgical device (OVD) in the fibrosed peripheral capsular tunnel avoids zonular or capsular stress. Internal wound enlargement permits foldable IOL removal in one piece, whilst preserving a self-sealing sutureless corneal wound. This technique may enhance the safety and efficacy of foldable IOL exchange. PMID:27366699

  16. Misdiagnosis induced intraocular lens dislocation in anterior megalophthalmos

    Institute of Scientific and Technical Information of China (English)

    WANG Qi-wei; XU Wen; ZHU Ya-nan; LI Jin-yu; ZHANG Li; YAO Ke

    2012-01-01

    Anterior megalophthalmos (AM) is an uncommon developmental anomaly of the anterior segment of the eye with a constellation of findings that includes enlarged cornea,deep anterior chamber,posterior positioning of the iris and lens,iris stroma atrophy,hypoplasia of iris dilator,pupil displacement,large capsular bag,lens subluxation,prematurely cataract and the tendency to retinal detachment.AM,especially when symptoms are mild,is not an easy disease to diagnose.We present 3 AM cases that were misdiagnosed as congenital cataract with weak zonule and megalocornea.Intraocular lenses (IOLs) dislocated after standard cataract surgeries and subsequent surgery (replacing the dislocated IOLs with iris-claw intraocular lenses) achieved satisfactory outcome.Although rare,AM should be included in the differential diagnosis of enlarged cornea and we recommend implanting Artisan lens in AM patients.

  17. Intraocular lens exchange-removing the optic intact.

    Science.gov (United States)

    Lee, Matthew Hao; Webster, Diane Lesley

    2016-01-01

    Current practice for intraocular lens (IOL) exchange is to cut the optic of the posterior chamber intraocular lens (PCIOL) prior to removing it. Great care must be taken during this maneuver to avoid a posterior capsular tear. Removing the haptics from the fibrosed capsule can also be hazardous, as it may result in zonular stress and dehiscence. A technique is described for performing foldable (one-piece acrylic) IOL removal without cutting the optic. Careful visco-dissection of the haptics with a low viscosity ophthalmic viscosurgical device (OVD) in the fibrosed peripheral capsular tunnel avoids zonular or capsular stress. Internal wound enlargement permits foldable IOL removal in one piece, whilst preserving a self-sealing sutureless corneal wound. This technique may enhance the safety and efficacy of foldable IOL exchange.

  18. A CLINICAL STUDY OF INTRAOCULAR PRESSURE CHANGES WITH VECURONIUM BROMIDE AND PANCURONIUM BROMIDE

    Directory of Open Access Journals (Sweden)

    Nagaraja

    2014-04-01

    Full Text Available BACKGROUND: The maintenance of intraocular pressure forms the mainstay of anesthetic management of intraocular surgery. It is desirable to achieve a normal or reduced intraocular pressure before the eye is opened to avoid expulsive hemorrhage and ocular disruption at the time of incision. Therefore the ideal anesthetic technique for intraocular surgery should produce a moderate reduction in intraocular pressure, or maintain intraocular pressure at near normal values and avoid marked fluctuations during surgery (George et al, 1979. The use of suxamethonium is associated with significant rise in intraocular pressure with a peak increase between 2 and 4 minutes following administration and return to base line value after 6 minutes. The outcome of eye surgery, particularly when there is globe injury depends to a large extent on good control of intraocular pressure not only during maintenance, but also at induction of anesthesia. This is usually achieved by use of non-depolarizing muscle relaxant. Pancuronium when used in relatively larger doses is known to have a faster onset of action and also the block may be prolonged. Vecuronium is intermediate acting and free of cardiovascular and other side effects even when used in larger doses. ABACKGROUND: The maintenance of intraocular pressure forms the mainstay of anesthetic management of intraocular surgery. It is desirable to achieve a normal or reduced intraocular pressure before the eye is opened to avoid expulsive hemorrhage and ocular disruption at the time of incision. Therefore the ideal anesthetic technique for intraocular surgery should produce a moderate reduction in intraocular pressure, or maintain intraocular pressure at near normal values and avoid marked fluctuations during surgery (George et al, 1979. The use of suxamethonium is associated with significant rise in intraocular pressure with a peak increase between 2 and 4 minutes following administration and return to base line value

  19. [The artificial lens: the folly of yesterday, the standard of today].

    Science.gov (United States)

    Meur, G

    1999-01-01

    Traditional cataract operation (dislocation of the crystalline lens into the vitreous body by external pressure or by needling) is nearly as old as mankind. The idea of implanting an artificial lenticulus is not new but this was only performed for the first time in 1949. In the last 50 years, a better knowledge of corneal and retinal physiology, as well as the improvements of intraocular lens material and design, have led to very safe routine surgery.

  20. Intraocular Pressure Following Intravitreal Injection of Triamcinolone Acetonide§

    OpenAIRE

    Ansari, Ejaz A; Ali, N

    2008-01-01

    Background: To investigate the intraocular pressure (IOP) response following intravitreal injection of triamcinolone acetonide. Methods: This retrospective consecutive non-comparative case series study included 41 patients (52 eyes) (19 male, 22 female, mean age 64.1 ± 13.44; range 22 – 85 years) with progressive exudative ARMD (n = 10 eyes) or diffuse diabetic macular oedema (42 eyes), who received one or more intravitreal injection(s) of 4 mg triamcinolone acetonide. Results: IOP increased ...

  1. NANOTECHNOLOGY IN THE TREATMENT AND DETECTION OF INTRAOCULAR CANCERS

    OpenAIRE

    Nair, Ashwin; Thevenot, Paul; Hu, Wenjing; Tang, Liping

    2008-01-01

    Tremendous progress in nanotechnology has lead to the development of nanometer-sized objects as medical implants or devices. Many of these nanodevices have recently been tested in many cancer diagnostic and therapeutic applications, such as leukemia, melanoma, breast tumor, prostate tumor, and brain cancer. Despite the increasing importance of nanotechnology in cancer, the potential of these nanodevices in diagnosing and treating intraocular cancers has not been systematically evaluated. This...

  2. Intraocular Pressure And Its Determinants In Tehran Population

    OpenAIRE

    Kashi AH; Fotouhil A; Hashemi H.; Mohammadl K

    2005-01-01

    Background: The aim of this study was to provide data, on the distribution or intraocular pressure (IOP) in Tehran population. Materials and Methods: Through a population-based, cross-sectional study, a total of 4565 Tehran citizens were studied in the Tehran Eye Study. The findings of the participants (n=3834) 10 years and older free of glaucoma diagnosis or suspicion who had undergone applanation tonometry examination are presented. All participants received a standardized protocol included...

  3. Black intraocular lens: another cosmetic approach to leukocoria

    OpenAIRE

    Pedrosa, C; Pina, S.; Azevedo, A.; Pêgo, P; Feijóo, B; Prieto, I

    2012-01-01

    Purpose – To present a case report of a black intraocular lens implantation for cosmetic improvement of a blind eye with leukocoria. Setting – Ophthalmology Department - Professor Dr. Fernando Fonseca Hospital, EPE - Amadora, Lisboa, Portugal Methods – We report a 32-year-old woman who was evaluated because of the undesired cosmetic appearance of her amblyopic left eye with exotropia and leukocoria due to traumatic cataract and total retinal detachment during childhood. The Examination ...

  4. Intraocular gnathostomiasis: A rare case report from Central India

    Science.gov (United States)

    Rawat, Preeti; Gautam, Manushree; Jain, Nikhila C; Jain, Rajdeep

    2016-01-01

    We report the first case of intraocular gnathostomiasis from Central India. A 29-year-old male from Indore, Madhya Pradesh, presented with pain and redness of the right eye since 1 month. Slit lamp examination revealed anterior uveitis, multiple iris atrophic patches, and a live worm hooked on iris. The worm was removed through a small sclerocorneal tunnel. Microscopy confirmed Gnathostoma spinigerum. The patient was treated with oral albendazole and steroids. The case is reported because of its rarity. PMID:27146938

  5. Metabolic syndrome: a risk factor for high intraocular pressure in the Israeli population

    Institute of Scientific and Technical Information of China (English)

    Tamara; Wygnanski-Jaffe; Itzhak; Bieran; Dorit; Tekes-Manova; Yair; Morad; Isaac; Ashkenazi; Eedy; Mezer

    2015-01-01

    AIM: To evaluate the association among elevated intraocular pressure(IOP), the metabolic syndrome(Met S), body mass index(BMI), and some of their components in the Israeli population.METHODS: We retrospectively reviewed the charts of12 747 soldiers of the Israeli Defense Forces, aged 35 y or older, who underwent a routine periodical medical examination between 1991 and 2004. None of the subjects received medical treatment for either glaucoma or ocular hypertension. High IOP(>21 mm Hg) was correlated with age, sex, arterial blood pressure, total blood cholesterol levels, triglyceride levels, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, smoking, BMI and Met S.RESULTS: A statistically significant difference was found between the IOP of subjects with a low risk and higher risk for the development of Met S(P <0.0001 for males, P =0.0026 for females). A statistically significant positive correlation was found in male subjects between high BMI and elevated IOP(r =0.11677, P <0.0001).CONCLUSION: Met S and BMI were significantly more prevalent in subjects with increased IOP levels. We suggest that both should be taken into consideration in the assessment of glaucoma suspects.

  6. Successful Removal of Large Intraocular Foreign Body by 25-Gauge Microincision Vitrectomy Surgery

    OpenAIRE

    Hiroshi Kunikata; Megumi Uematsu; Toru Nakazawa; Nobuo Fuse

    2011-01-01

    We describe a new technique for removing a large intraocular foreign body by 25-gauge microincision vitrectomy surgery (25G-MIVS). Noncomparative interventional case series were performed at a single centre. Two patients with a long smooth intraocular vitreal foreign body underwent phacoemulsification and aspiration, intraocular lens implantation, 25G-MIVS, and extraction of the foreign body. The foreign body was removed through a posterior capsulorhexis, anterior continuous curvilinear capsu...

  7. Effects of Mirtogenol® on ocular blood flow and intraocular hypertension in asymptomatic subjects

    OpenAIRE

    Steigerwalt, Robert D; Gianni, Belcaro; Paolo, Morazzoni; Bombardelli, Ezio; Burki, Carolina; Schönlau, Frank

    2008-01-01

    Purpose The most important variable risk factor for developing glaucoma is intraocular hypertension. Timely lowering of high intraocular pressure (IOP) significantly lowers the likelihood of developing glaucoma. The aim of this study was to evaluate the effects of the food supplement Mirtogenol® (Mirtoselect® and Pycnogenol®) on IOP and ocular blood flow in a product evaluation study. Methods Thirty-eight asymptomatic subjects with intraocular hypertension were either given Mirtogenol® (20 su...

  8. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  9. Posterior chamber phakic intraocular lens implantation for high myopia

    Institute of Scientific and Technical Information of China (English)

    沈晔; 杜持新; 顾扬顺; 王竞

    2003-01-01

    Objective To evaluate the efficacy, safety and stability of posterior chamber phakic intraocular lens (PIOLs) implantation for the correction of high myopia.Methods Thirty-nine eyes of twenty patients with high myopia (between-11.75 and-25.75 diopters) had a posterior chamber PIOL (Staar ICL) implanted. During 6-48 months' follow-up, visual acuity, refraction, intraocular pressure (IOP), corneal reaction and space between crystal lens and intraocular lens (IOLs) were tested.Results Successful implantation was achieved in all patients. Visual acuity without correction greater than 0.5 was found in 34 eyes at 1 day and 3 months postoperatively. Thirty-five eyes maintained a low negative power of refraction (-1.42±1.32 doipters), which did not prevent the patients from most of their daily activities. During 3-48 months' follow-up, refraction was stable and no cornea edema and glaucoma was found. Two eyes of one patient had corticosteroid glaucoma and another eye showed cataractogenesis under anterior capsular membrane.Conclusion Posterior chamber PIOL implantation is predictable, safe, and effective in the correction of high myopia, and its indications should be carefully selected.

  10. Removal of Intralenticular Magnetic Foreign Bodies with Intraocular Magnet

    Institute of Scientific and Technical Information of China (English)

    Yiwen Luo; Zhenfang Wang; Xiaofeng Lin; Shuying Hu

    2003-01-01

    Purpose: To investigate the possibility of conservation of the lens after removal of intralenticular magnetic foreign bodies with intraocular magnet.Methods: Intralenticular magnetic foreign bodies of 15 patients were removed by using an intraocular magnet. The lens of each injury eye was conserved. Follow-up observation of these cases ranged from one to four years.Results: The intralenticular magnetic foreign bodies of 15 patients were successfully removed.The lens of each injury eye was conserved and the transparence of the lens was properly maintained. Sizes of these foreign bodies were measured, ranging from 0.3 mm to 3mm in diameter. The follow-up observation showed that the corrected visual acuity of 14 cases was not changed after operation.Conclusions: The intraocular magnet is very helpful for removal of magnetic foreign bodies from the transparent lens. This magnet allows removing of the foreign body by the surgeon and no damage to the lens was induced during the operation. Thus, maintenance of visual acuity of most of the patients can be achieved.

  11. Microscopic and spectroscopic investigation of an explanted opacified intraocular lens

    Science.gov (United States)

    Simon, V.; Radu, T.; Vulpoi, A.; Rosca, C.; Eniu, D.

    2015-01-01

    The investigated polymethylmethacrylate intraocular lens explanted an year after implantation presented a fine granularity consisting of ring-like grains of about 15 μm in diameter. In order to evidence the changes occurred on intraocular lens relative to morphology, elemental composition and atomic environments, microscopic and spectroscopic analyses were carried out using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), energy-dispersive X-ray (EDS), and X-ray photoelectron (XPS) spectroscopies. The results revealed that the grains contain hydroxyapatite mineral phase. A protein layer covers the lens both in opacified and transparent zones. The amide II band is like in basal epithelial cells. The shape and size of the grains, and the XPS depth profiling results indicate the possibility of a cell-mediated process involving lens epithelial cells which fagocitated apoptotic epithelial cells, and in which the debris derived from cell necrosis were calcified. To the best of our knowledge, this is the first investigation on explanted intraocular lenses using XPS depth profiling in order to examine the inside of the opacifying deposits.

  12. Comparison of visual performance of multifocal intraocular lenses with same material monofocal intraocular lenses.

    Directory of Open Access Journals (Sweden)

    Tomofusa Yamauchi

    Full Text Available PURPOSE: To compare the visual performance of multifocal intraocular lenses (IOLs and monofocal IOLs made of the same material. METHODS: The subjects included patients implanted with either Tecnis® monofocal IOLs (ZA9003 or ZCB00 or Tecnis® multifocal IOLs (ZMA00 or ZMB00 bilaterally. We conducted a retrospective study comparing the two types of IOLs. The multifocal group included 46 patients who were implanted with Tecnis® multifocal IOLs bilaterally. The monofocal group was an age- and sex-matched control group, and included 85 patients who were implanted with Tecnis® monofocal IOLs bilaterally. Lens opacity grading, the radius of corneal curvature, corneal astigmatism, axial length and the refractive status were measured preoperatively. Pupil size, ocular aberrometry, distance, intermediate and near visual acuity, contrast sensitivity with and without glare and the responses to a quality-of-vision questionnaire were evaluated pre- and postoperatively. RESULTS: The uncorrected near visual acuity was significantly better in the multifocal group, whereas both the corrected intermediate and near visual acuity were better in the monofocal group. Contrast sensitivity (with and without glare was significantly better in the monofocal group. The rate of spectacle dependency was significantly lower in the multifocal group. There were no significant differences between the two groups regarding most items of the postoperative quality-of-vision questionnaire (VFQ-25, with the exception that the patients in the monofocal group reported fewer problems with nighttime driving. CONCLUSIONS: The multifocal IOLs used in this study reduced spectacle dependency more so than monofocal IOLs and did not compromise the subjective visual function, with the exception of nighttime driving.

  13. Keeping an eye on dialysis: the association of hemodialysis with intraocular hypertension.

    Science.gov (United States)

    William, Jeffrey H; Gilbert, Aubrey L; Rosas, Sylvia E

    2015-11-01

    Intraocular hypertension is common during hemodialysis. Dialysis disequilibrium syndrome and intraocular hypertension occur via similar pathophysiologic mechanisms. These mechanisms may contribute to the development of glaucoma and cataracts in a patient population already at high risk for ocular abnormalities, given the common risk factors for chronic kidney disease and impaired aqueous humor outflow. We describe a patient with complicated diabetes mellitus, end-stage renal disease, and recent cataract surgery who developed severe intraocular hypertension during hemodialysis. We recommend increased awareness of the symptoms of intraocular hypertension and subsequent ophthalmologic surveillance in order to prevent long-term visual complications. PMID:26042412

  14. Coculture with intraocular lens material-activated macrophages induces an inflammatory phenotype in lens epithelial cells.

    Science.gov (United States)

    Pintwala, Robert; Postnikoff, Cameron; Molladavoodi, Sara; Gorbet, Maud

    2015-03-01

    Cataracts are the leading cause of blindness worldwide, requiring surgical implantation of an intraocular lens. Despite evidence of leukocyte ingress into the postoperative lens, few studies have investigated the leukocyte response to intraocular lens materials. A novel coculture model was developed to examine macrophage activation by hydrophilic acrylic (poly(2-hydroxyethyl methacrylate)) and hydrophobic acrylic (polymethylmethacrylate) commercial intraocular lens. The human monocytic cell line THP-1 was differentiated into macrophages and cocultured with human lens epithelial cell line (HLE-B3) with or without an intraocular lens for one, two, four, or six days. Using flow cytometry and confocal microscopy, expression of the macrophage activation marker CD54 (intercellular adhesion molecule-1) and production of reactive oxygen species via the fluorogenic probe 2',7'-dichlorodihydrofluorescein diacetate were examined in macrophages. α-Smooth muscle actin, a transdifferentiation marker, was characterized in lens epithelial cells. The poly(2-hydroxyethyl methacrylate) intraocular lens prevented adhesion but induced significant macrophage activation (p intraocular lens), while the polymethylmethacrylate intraocular lens enabled adhesion and multinucleated fusion, but induced no significant activation. Coculture with either intraocular lens increased reactive oxygen species production in macrophages after one day (p intraocular lens, with hydrophilic surfaces inducing higher activation than hydrophobic surfaces. These findings provide a new method of inquiry into uveal biocompatibility, specifically through the quantification of cell-surface markers of leukocyte activation.

  15. The Effect of Phacoemulsification with Posterior Chamber Intraocular Lens Implantation on Intraocular Pressure and Anterior Chamber Depth

    Directory of Open Access Journals (Sweden)

    Mohammad Javad Mohamadi

    2013-12-01

    Full Text Available Purpose: To evaluate intraocular pressure (IOP and anterior chamber depth (ACD change after phacoemulsification with posterior chamber intraocular lens implantation Methods: In this quasi-experimental study, 84 patients with senile cataract were included. All patients had normal IOP. Patients with traumatic and complicated cataract, any history of uveitis, glaucoma, or other ocular disease or surgery were excluded. Patients underwent phacoemulsification and intraocular lens implantation by the same surgeon. IOP, ACD, and lens thickness were measured and recorded before surgery. IOP was measured at 4, 8 and 12 postoperative weeks and ACD was measured 12 weeks after surgery. Results: The mean preoperative ACD significantly increased from 2.93 mm to 3.54 mm postoperatively (p<0.0001. Mean preoperative IOP was 16.06 mmHg which decreased to 12.01 IOP mmHg, 12.57 mmHg and 12.90 mmHg at 4 weeks, 8 weeks and 12 weeks postoperatively, respectively (all p-values<0.0001. There was a correlation between lens thickness and changes of and ACD after the surgery. There was also a positive correlation between preoperative IOP and IOP reduction after the surgery. Conclusion: Phacoemulsification decreases IOP specially in eyes with higher preoperative IOP and thicker lenses.

  16. A capacitor-based sensor and a contact lens sensing system for intraocular pressure monitoring

    Science.gov (United States)

    Chiou, Jin-Chern; Huang, Yu-Chieh; Yeh, Guan-Ting

    2016-01-01

    This study proposes a capacitor-based sensor on a soft contact lens for the measurement of intraocular pressure (IOP). The sensor was designed and fabricated via microelectromechanical system fabrication technologies. The soft contact lens is designed to be worn on a cornea such that the curvature of the contact lens corresponds substantially to that of the cornea. In addition, the contact lens was fabricated via a cast-molding method using poly-2-hydroxyethyl methacrylate to achieve a lens with high oxygen permeability, which can be worn comfortably for a long time. An IOP sensor prototype was implemented, which exhibited 1.2239 pF mmHg-1 (13,171 ppm mmHg-1) sensitivity during measurements of an artificial anterior chamber at pressures between 18 and 30 mmHg. The results indicate that the developed capacitor-based IOP sensor exhibited high stability and reproducibility in a series of measurements performed under various pressures. The capacitance of the proposed IOP sensor can successfully be converted into a digital value via a capacitor-to-digital converter and be transmitted via a commercial wireless telemetry system in this study.

  17. Experimental intraocular infection of exotic cockerels with field strain of velogenic Newcastle disease virus in Nigeria

    Directory of Open Access Journals (Sweden)

    Samaila Jonathan Badau

    2015-12-01

    Full Text Available Experimental intraocular (conjunctival infection of exotic cockerels with a new field strain of viscerotropic velogenic Newcastle Disease Virus (NDV was conducted to explore the concurrence of some pathological changes with humoral immune responses. After the NDV infection of 4-week-old cockerels, pathologic changes and antibody responses were observed. The clinical signs observed after the artificial inoculation included inappetence, depression, diarrhea, dyspnea, wing and leg paralysis, torticollis and weight loss. Morbidity due to the NDV was 100%, but mortality was 80% by day 18-21 post-infection. Early hyperthermia followed by terminal hypothermia, decreased packed cell volume (PCV, and 231.4 folds peak-antibody response were observed. Necrotic and/or inflammatory lesions were present in the proventriculus, intestine, liver, spleen, kidney and brain. Neurologic and digestive tract perturbations occurred in 10% and 85% of cases, respectively. The disease consistently caused stunted growth, decreased PCV, and necro-inflammatroy lesions concurrent with antibody response, suggesting probable involvement of immune-mediated mechanisms and cell membrane desialylation by viral neuraminidase in the pathogenesis.

  18. Preoperative automatic visual behavioural analysis as a tool for intraocular lens choice in cataract surgery

    Directory of Open Access Journals (Sweden)

    Heloisa Neumann Nogueira

    2015-04-01

    Full Text Available Purpose: Cataract is the main cause of blindness, affecting 18 million people worldwide, with the highest incidence in the population above 50 years of age. Low visual acuity caused by cataract may have a negative impact on patient quality of life. The current treatment is surgery in order to replace the natural lens with an artificial intraocular lens (IOL, which can be mono- or multifocal. However, due to potential side effects, IOLs must be carefully chosen to ensure higher patient satisfaction. Thus, studies on the visual behavior of these patients may be an important tool to determine the best type of IOL implantation. This study proposed an anamnestic add-on for optimizing the choice of IOL. Methods: We used a camera that automatically takes pictures, documenting the patient’s visual routine in order to obtain additional information about the frequency of distant, intermediate, and near sights. Results: The results indicated an estimated frequency percentage, suggesting that visual analysis of routine photographic records of a patient with cataract may be useful for understanding behavioural gaze and for choosing visual management strategy after cataract surgery, simultaneously stimulating interest for customized IOL manufacturing according to individual needs.

  19. Artificial Economy

    Directory of Open Access Journals (Sweden)

    Alexandru JIVAN

    2011-08-01

    Full Text Available This paper proposes to eliminate, a routine in the economic thinking, claimed to be responsible for the negative essence of economic developments, from the point of view, of the ecological implications (employment in the planetary ecosystem. The methodological foundations start from the natural origins of the functionality of the human economic society according to the originary physiocrat liberalism, and from specific natural characteristics of the humankind. This paper begins with a comment-analysis of the difference between natural and artificial within the economy, and then explains some of the most serious diversions from the natural essence of economic liberalism. It shall be explained the original (heterodox interpretation of the Classical political economy (economics, by making calls to the Romanian economic thinking from aggravating past century. Highlighting the destructive impact of the economy - which, under the invoked doctrines, we call unnatural - allows an intuitive presentation of a logical extension of Marshall's market price, based on previous research. Besides the doctrinal arguments presented, the economic realities inventoried along the way (major deficiencies and effects, determined demonstrate the validity of the hypothesis of the unnatural character and therefore necessarily to be corrected, of the concept and of the mechanisms of the current economy.The results of this paper consist of original heterodox methodspresented, intuitive or developed that can be found conclusively within the key proposals for education and regulation.

  20. Linfoma intra-ocular primário de células tipo B: relato de caso Primary intraocular B-cell lymphoma: case report

    OpenAIRE

    Marcela Cypel; Rubens Belfort Jr; Nilva Moraes; Cristina Muccioli

    2007-01-01

    O linfoma não-Hodgkin primariamente intra-ocular é raro, e caracterizado por uma forma extranodal que pode envolver retina, espaço sub-retiniano, vítreo e nervo óptico. Ocorre independente ou associado ao linfoma do sistema nervoso central e freqüentemente na forma de uveíte de difícil tratamento. Esta forma de linfoma é um dos tumores intra-oculares mais desafiantes de se diagnosticar. Relatamos um caso de linfoma não-Hodgkin intra-ocular difuso de células grandes tipo B numa paciente de 47 ...

  1. Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens

    Science.gov (United States)

    Lee, Shinwook; Choi, Myoung; Xu, Zaiwei; Zhao, Zeyu; Alexander, Elsinore; Liu, Yueai

    2016-01-01

    Purpose The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. Methods The optical characteristics of AcrySof® IQ PanOptix™ (PanOptix) and AcrySof® IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal images, simulated headlight images, and modulation transfer function (MTF) measurements which determine resolution, photic phenomena, and image quality. Through-focus Badal images of an Early Treatment of Diabetic Retinopathy Study chart were recorded at both photopic and mesopic pupil sizes. Simulated headlight images were taken on an MTF bench with a 50-μm pinhole target and a 5.0 mm pupil at the distance focus of the IOL. MTF curves were measured with a 3.0 mm pupil, and spatial frequencies equivalent to 20/40 and 20/20 visual acuities were recorded to illustrate the through-focus MTF curves. Far-, intermediate-, and near-focus MTF values were obtained. Results Bench Badal image testing and MTF measurements showed that PanOptix has a near focus at a distance of 42 cm and an additional intermediate focus at a distance of about 60 cm. The near focus for ReSTOR +3.0 D is at 45 cm. PanOptix and ReSTOR +3.0 D have comparable photopic distances and near MTF values. Additionally, PanOptix provided a substantial continuous range of vision from distance to intermediate and to near compared with ReSTOR +3.0 D. The halo propensity for PanOptix was slightly higher than that for ReSTOR +3.0 D. Conclusion Laboratory-based in vitro simulations showed that PanOptix trifocal IOL has comparable resolution and image quality performance in distance and near foci compared with ReSTOR +3.0 D IOL. PanOptix showed better resolution and image quality performance at the intermediate focus than ReSTOR +3.0 D IOL. PMID:27330273

  2. INTRAOCULAR AND SERUM LEVELS OF VASCULAR ENDOTHELIAL GROWTH FACTOR IN ACUTE RETINAL NECROSIS AND OCULAR TOXOPLASMOSIS

    NARCIS (Netherlands)

    Wiertz, Karin; De Visser, Lenneke; Rijkers, Ger; De Groot-Mijnes, Jolanda; Los, Leonie; Rothova, Aniki

    2010-01-01

    Purpose: To determine the intraocular and serum vascular endothelial growth factor (VEGF) levels in patients with acute retinal necrosis (ARN) and compare those with VEGF levels found in patients with ocular toxoplasmosis (OT). Methods: Paired intraocular fluid and serum samples of 17 patients with

  3. Extracapsular cataract extraction : the fate of retained lens material and intraocular lenses

    NARCIS (Netherlands)

    J.P. Kappelhof (Johan)

    1987-01-01

    textabstractThe aim of this study was to examine the fate of the lens material that remains in the eye after an extracapsular cataract extraction both with and without insertion of an intraocular lens. Apart from this, the development of precipitates on the intraocular lenses was morphologically inv

  4. Repositioning a decentered intraocular lens with 4 haptics.

    Science.gov (United States)

    Liu, Jiewei; Liu, Wenjie; Jia, Yading; Al-Mohtaseb, Zaina N; Wang, Li

    2016-03-01

    We describe a technique to reposition a decentered 4-haptic intraocular lens (IOL). Using an ophthalmic viscosurgical device, the haptic with the worst distortion is dissected from the capsular bag and pulled outside the bag. The opposite haptic (180 degrees away) is also dissected and placed in front of the anterior capsule. The remaining 2 haptics are left in the capsular bag. With this repositioning, the 2 haptics in the bag limit the IOL movement, the 2 haptics outside the bag are no longer distorted, and the IOL is centered. We present 2 cases in which this technique was used to reposition decentered 4-haptic IOLs.

  5. Effect of transscleral neodymium: YAG cyclophotocoagulation on intraocular lenses

    Energy Technology Data Exchange (ETDEWEB)

    Blomquist, P.H.; Gross, R.L.; Koch, D.D. (Baylor College of Medicine, Houston, TX (USA))

    1990-03-01

    A neodymium: YAG laser operating in the thermal mode was used to irradiate isolated intraocular lenses (IOLs) and to perform transscleral cyclophotocoagulation on pseudophakic autopsy eyes to investigate the potential damage to IOL haptics such irradiation may cause. In the isolated IOLs, 70 mJ of energy deformed and partially melted both polymethylmethacrylate (PMMA) and polypropylene haptics. One of the capsular-fixated PC-IOL haptics in an autopsy eye partially melted when irradiated with the maximum energy level (8.8 J), with the aiming beam focused 1 mm posterior to the limbus and maximal posterior focus offset.

  6. Cerebral migration of intraocular silicone oil: an MRI study

    DEFF Research Database (Denmark)

    Kiilgaard, Jens Folke; Milea, Dan; Løgager, Vibeke;

    2011-01-01

    for retinal detachment. Methods: Nineteen patients included in this study were referred for silicone oil removal after uncomplicated retinal detachment surgery using internal silicone oil tamponade. Patients with a previous history of intraocular silicone oil, glaucoma or optic pit were excluded. After...... informed consent, the patients underwent magnetic resonance imaging (MRI). Fat saturation as well as short T1 inversion recovery (STIR) sequences combined with water saturation allowed silicone oil to be easily detectable. Results: The mean delay between the silicone oil injection and the MRI procedure...

  7. Delayed Hyphema after Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    A56-year-old man with senile cataract in the left eye underwent extracapsularcataract extraction(ECCE)and posteriorchamber intraocular lens(IOL)implanta-tion on December 19,1988.A 13D J-loopplannar lens was inserted in the ciliary sul-cus.The operation was successful with mildpostoperative response.His corrected visionwas 20/20. He had a follow-up examination onMarch 20,1989.No complication was notedand his vision retained 20/20.In theevening of the same day,the patient sud-denly felt discomfortable and...

  8. Akreos Adapt AO Intraocular Lens Opacification: A Case Report

    Directory of Open Access Journals (Sweden)

    Matteo Forlini

    2013-09-01

    Full Text Available A 79-year-old hyperglycemic patient was referred to the ‘Santa Maria delle Croci' Hospital, Ravenna, Italy. He presented with visual impairment in the right eye. Four years ago, he had had an uneventful cataract surgery in the right eye. We observed an opacification of the intraocular lens (IOL causing significant visual disturbance. The IOL was exchanged. Unfortunately, pathologic analysis was not performed. Patient-related factors such as hyperglycemia and hypertension might have been responsible for the opacification. To our knowledge, there is only one previous report of opacification of the Akreos Adapt AO IOL.

  9. Technology needs for the development of the accommodative intraocular lens

    Science.gov (United States)

    Nishi, Okihiro

    2010-02-01

    Refilling the lens capsule while preserving capsular integrity offers the potential to restore ocular accommodation. There are two persisting problems in capsular bag refilling for possible clinical application: Leakage of the injectable material through the capsular opening and capsular opacification. Numerous attempts for solving these cardinal problems have not been proven to be clinically applicable. Recently, we developed a novel capsular bag refilling procedure using a novel accommodative intraocular lens that serves as an optic as well as a plug for sealing the capsular opening. The procedure and the results of monkey experiments will be presented.

  10. Intraocular pressure in very low birth weight preterm infants and its association with postconceptional age

    Directory of Open Access Journals (Sweden)

    Rodrigo L. Lindenmeyer

    2012-11-01

    Full Text Available OBJECTIVE: To evaluate intraocular pressure in very low birth weight preterm infants and correlate it with postconceptional age. METHODS: The intraocular pressure in a prospective cohort of very low birth weight premature infants (defined as a birth weight <1,500 g and gestational age <32 weeks admitted to Hospital de Clínicas de Porto Alegre , Brazil was evaluated weekly. The evaluated outcome was the variation in the intraocular pressure following changes in the postconceptional age (defined as the gestational age at birth plus the age in weeks at the time of examination in the weeks following preterm birth. Mixed-effects models were used for the statistical analysis to determine the intraocular pressure variation according to postconceptional age, and means and 10th and 90th percentiles were calculated for the intraocular pressure values. RESULTS: Fifty preterm infants with a mean gestational age of 29.7 ± 1.6 weeks and a mean birth weight of 1,127.7 ± 222.7 g were evaluated. The mean intraocular pressure for the entire cohort considering both eyes was 14.9 ± 4.5 mmHg, and 13.5% of all recorded intraocular pressure values were greater than 20 mmHg. The analysis revealed a mean reduction in the intraocular pressure of 0.29 mmHg for each increase in postconceptional age (p = 0.047; 95% CI: -0.58 to -0.0035. The mean intraocular pressure (P10-P90 decreased from 16.3 mmHg (10.5222.16 at 26.3 weeks to 13.1 mmHg (7.28-18.92 at 37.6 weeks of postconceptional age. CONCLUSIONS: The mean intraocular pressure in very low birth weight preterm infants was 14.9 ± 4.5 mmHg. This value decreased 0.29 mmHg per week as the postconceptional age increased.

  11. Mirtogenol® potentiates latanoprost in lowering intraocular pressure and improves ocular blood flow in asymptomatic subjects

    Directory of Open Access Journals (Sweden)

    Robert D Steigerwalt Jr

    2010-05-01

    Full Text Available Robert D Steigerwalt Jr1, Gianni Belcaro1, Paolo Morazzoni2, Ezio Bombardelli2, Carolina Burki3, Frank Schönlau4 1Department of Biomedical Sciences, University of Chieti-Pescara, San Valentino, Italy; 2Indena S.p.A. Scientific Department, Milan, Italy; 3Horphag Research (UK Ltd., Geneva, Switzerland; 4Horphag Research (UK Ltd. South Kensington, London UKPurpose: The dietary supplement Mirtogenol® was previously shown to lower elevated intraocular pressure (IOP. We here present the effects of this supplement on IOP in comparison as well as in combination with latanoprost eye drops. Methods: Seventy-nine patients with asymptomatic ocular hypertension were randomly assigned to three groups receiving either the supplement, or latanoprost eye drops, or both in combination. Intraocular pressure and retinal blood flow were investigated in monthly intervals over 24 weeks.Results: Mirtogenol alone lowered IOP from baseline 38.1 to 29.0 mmHg after 16 weeks, with little further improvement during the following eight weeks. Latanoprost rapidly lowered IOP from baseline 37.7 to 27.2 mmHg within four weeks, without further effects thereafter. The combination of the supplement and latanoprost lowered IOP from 38.0 to 27.3 mmHg after four weeks, and further decreased IOP to 24.2 mmHg after six weeks. After 24 weeks IOP with the combination treatment (23.0 mmHg was significantly lower than with latanoprost alone (27.2 mmHg. Mirtogenol and latanoprost individually showed comparable effects for gradually increasing central artery blood flow with treatment duration. Combination treatment showed higher systolic blood flow velocity throughout the trial period. The diastolic blood flow velocity gradually increased with treatment duration in all three groups. From twelve weeks onwards, the diastolic component with combination treatment was higher than with individual treatments.Conclusions: Mirtogenol lowered elevated IOP in patients almost as effectively as

  12. Effect of phacoemulsification and intraocular lens implantation combined with vitrectomy on the dynamic changes of intraocular pressure%超声乳化人工晶体植入术联合玻璃体切除术对眼内压动态变化的影响

    Institute of Scientific and Technical Information of China (English)

    王晓鹏

    2012-01-01

    Objective To investigate the effect of phacoemulsification and intraocular lens implantation combined with vitrectomy on the dynamic changes of intraocular pressure.Methods A sample of 73 eyes of 70 patients was divided into two groups according to the operation method.Phacoemulsification and intraocular lens combined with vitrectomy implantation performed on 38 eyes of 37 patients (study group) were compared with vitrectomy alone performed on 35 eyes of 33 patients (control group).The dynamic changes of intraocular pressure 1,2,3 days,1,3 weeks,1,2,3 months after surgery were observed.Results The intraocular pressure was peaked on the 1st day after surgery in control group from ( 13.7 ± 2.2)mm Hg ( 1 mm Hg =0.133 kPa) preoperatively to ( 18.5 ± 6.9) mm Hg postoperatively,and recovered the preoperative level on the 3rd day after surgery.The intraocular pressure was peaked on the 1st day after surgery in study group from ( 12.9 ± 2.4) mm Hg preoperatively to (23.4 ± 8.0) mm Hg postoperatively,and recovered the preoperative level on the 3rd week after surgery.The intraocular pressure in both groups displayed an significant elevation on postoperative days,although degree of intraocular pressure elevation in study group was higher than that in control group (P <0.05).The correlation analysis showed:diabetic retinopathy,and combined with cataract extraction and lens implantation were independent risk factors of intraocular pressure surge (the intraocular pressure ≥10 mm Hg) after vitrectomy. Conclusions Phacovitrectomy and intraocular lens implantation increases the risk of transient intraocular pressure elevation in early postoperative stage than vitrectomy alone.The patients who are vulnerable to intraocular pressure fluctuations when performed a combined surgery should be paid more attention.%目的 探讨超声乳化人工晶体植入术联合玻璃体切除术(PPV)对患者眼内压动态变化的影响.方法 选择需行PPV治疗患者70例(73眼)为研

  13. Analyses of ERG in a patient with intraocular lymphoma

    Directory of Open Access Journals (Sweden)

    Chieko Yasuda

    2010-04-01

    Full Text Available Chieko Yasuda, Shinji Ueno, Mineo Kondo, Nagako Kondo, Chang-Hua Piao, Hiroko TerasakiDepartment of Ophthalmology, Nagoya University School of Medicine, Nagoya, JapanPurpose: To follow the changes in the electroretinograms (ERGs in a patient with primary intraocular lymphoma (PIOL who had a complete remission after chemotherapy. Methods: ERGs were recorded in a 41-year-old woman with PIOL during and after complete remission with chemotherapy. The patient was diagnosed with PIOL from both the ocular signs and the medical history of cranial lymphoma.Results: The ERGs were depressed in the subject. The amplitudes of the bright white flash b-waves were smaller than the a-waves, resulting in a “negative type” ERG. Six weeks after the beginning of chemotherapy, the ocular changes had resolved, and the ERGs, although not of the “negative type”, still showed signs that the amplitude had not returned to normal levels.Conclusion: The negative type ERGs indicated that the inner retina had been damaged to a greater extent than the outer retina. In the convalescent stage, when the ocular manifestations were resolved, the ERGs were still not fully recovered. Although only one case was studied, we suggest that ERGs can be used to evaluate and follow patients with a PIOL.Keywords: electroretinogram, primary intraocular lymphoma, uveitis masquerade syndrome

  14. Ultrasound Biomicroscopy of Iris-claw Phakic Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Ayong Yu; Zhende Lin; Xiaoyu Cai; Xiuqi Chen; Shuke Luo; Yonghua Li

    2006-01-01

    Purpose: To study in situ the intraocular position of iris-claw phakic intraocular lens (ICPIOL) in myopic eyes using ultrasound biomicroscopy (UBM).Methods: UBM echograms of the anterior segment were taken preoperatively and 62to 115 days postoperatively in 6 eyes implanted with the Verisys ICPIOL (AMO). The echograms were assessed for the effect of the ICPIOL on iris tissue.Results: The preoperative distance between the corneal endothelium and the lens ranged from 2.96 to 3.09 mm, and the postoperative distance between the ICPIOL and the corneal endothelium, from 1.86 to 2.03 mm. The distance between the lens and the posterior surface of the ICPIOL ranged from 0.61 to 0.76 mm. The distance between the superior, inferior optic edge and the iris ranged from 0.49 to 1.00 mm,0.21 to 0.51 mm respectively. The shortest distance between the ICPIOL haptics and the angle of anterior chamber ranged from 1.25 to 1.65 mm. The indentation of iris tissue by the ICPIOL haptics without pigmentary dispersion and distortion of posterior curvature of iris was observed.Conclusion: Adequate space is maintained between the Verisyse myopic ICPIOL and the corneal endothelium, angle, and crystalline lens. Haptic indentation of the iris without pigment erosion and distortion of iris curvature is noted. The ICPIOL implanted in phakic eyes is a safe alternative for treatment of high myopia.

  15. Multifocal Toric Intraocular Lens for Traumatic Cataract in a Child

    Directory of Open Access Journals (Sweden)

    Yanfeng Zeng

    2016-10-01

    Full Text Available A child suffering from traumatic cataract and corneal astigmatism of 2.14 D had a phacoemulsification operation and implantation of a ReSTOR Toric intraocular lens (IOL to correct the astigmatism. The primary outcome measurements were the uncorrected distance visual acuity (UDVA, uncorrected near vision at 40 cm, intraocular pressure, spherical equivalent refraction, residual astigmatism, corneal astigmatism, presence of unusual optical phenomena, and use of spectacles. At 7 months postoperatively, UDVA was maintained between 16/20 and 24/20, near vision was between J1 and J3, residual spherical refraction was 0–0.37 D, and residual refractive cylinder was between 0 and 0.67 D. A multifocal toric IOL can provide the possibility of satisfactory vision for both distant and near conditions without the use of spectacles to meet children’s needs when studying and doing sports. Additionally, binocular vision can be reconstructed. This intervention, therefore, seems to be a satisfactory alternative.

  16. Intraocular lenses and clinical treatment in paediatric cataract

    Directory of Open Access Journals (Sweden)

    Camila Ribeiro Koch Pena

    2015-06-01

    Full Text Available Pediatric cataract is the most common treatable cause of blindness in children. Prevalence, etiology and morphology vary with the socioeconomic development. The treatment goal is to reduce amblyopia, being difficult management especially in unilateral cases. The decision on aphakia or primary intraocular lens should be individualized as well as correction with contact lens or spectacles. The intraocular lens single-piece hydrophobic acrylic are the most implanted in children and the preferably is in the capsular bag. The Sanders-Retzlaff-Kraff theoretic (SRK/T stressing that is described as more predictable, following Holladay I and SRK II and the recommendation is to under correction +6.0 or +8.0 dioptrias expecting the growth of the eye. The posterior capsule opacity is the most frequent complication and varies with the material choice of the lens. Glaucoma is the most serious postoperative complication and depends on the timing of the surgery, primary lens implantation and time of post surgical follow-up. The adherence to occlusion therapy with patching is critical to the visual prognosis and is determined by the child’s age and laterality of the cataract. There was significant improvement in the surgery and in IOLs, however the final visual prognosis is still not desirable.

  17. Diffractive multifocal intraocular lens interferes with intraoperative view

    Directory of Open Access Journals (Sweden)

    Mami Yoshino

    2010-05-01

    Full Text Available Mami Yoshino1, Makoto Inoue1,2, Nae Kitamura1, Hiroko Bissen-Miyajima11Department of Ophthalmology, Tokyo Dental College Suidobashi Hospital, Tokyo, Japan; 2Kyorin Eye Center, Kyorin University School of Medicine, Tokyo, JapanAbstract: We report an unusual finding during vitreous surgery in an eye implanted with a diffractive multifocal intraocular lens (IOL. A 70-year-old woman reported gradual visual deterioration to 20/40 in the left eye two and a half years after uneventful cataract surgery with implantation of a diffractive multifocal IOL. Funduscopic examination showed an epiretinal membrane (ERM in the left eye. Increased macular traction was believed to cause the visual deterioration. Vitreous surgery with removal of the ERM was performed and triamcinolone acetonide (TA was injected intravitreally to visualize the residual vitreous cortex. Although the ERM was peeled successfully, the ability to focus on the vitreoretinal interface through the IOL required great effort with decreased contrast sensitivity and ghost images of the intravitreal TA crystals. The vision improved to 20/25 4 months postoperatively. Macular surgery can be performed in an eye with a diffractive multifocal IOL; however, decreased contrast sensitivity and ghost images may interfere with the intraoperative view through the diffractive IOL in complicated cases.Keywords: diffractive multifocal intraocular lens, intraoperative view

  18. Posterior Iris Fixated Intraocular Lens for Pediatric Traumatic Cataract

    Science.gov (United States)

    Kavitha, V.; Balasubramanian, Preethi; Heralgi, Mallikarjun M.

    2016-01-01

    Purpose: To evaluate the postoperative visual outcomes and complications of posterior iris fixated intraocular lens (IFIOL) implantation for pediatric traumatic cataract. Methods: A retrospective clinical audit was performed of all the pediatric traumatic cataract patients who underwent lens removal and iris fixated lens implantation due to inadequate capsular support with or without corneal tear repair between January 2009 and December 2013. Data were collected and analyzed on the preoperative and postoperative visual outcomes and complications. Results: Twenty-five children (25 eyes; 21 males and 4 females) were enrolled with the mean age of 11 ± 4.0 years. There were 72% of eyes that underwent primary cataract removal with IFIOL implantation. Twenty-eight percent of eyes underwent corneal tear repair prior to intraocular lens (IOL) implantation. Preoperative best corrected visual acuity (BCVA) was hand motion in 32% eyes, counting fingers in 24%, and perception of light in 44%. Postoperative BCVA of 0-0.2 logarithm of minimum angle of resolution was reported in the 64% of eyes. One eye developed secondary glaucoma, one eye underwent re-enclavation, and none developed retinal complications. Conclusion: Posterior IFIOL implantation resulted in an improved visual outcome, low incidence of postoperative complications, and is a good alternative to other IOL, in the cases of pediatric traumatic cataract without adequate capsular support. PMID:27162456

  19. Survey of Intraocular Antibiotics Prophylaxis Practice after Open Globe Injury in China

    Science.gov (United States)

    Tan, Junlian; Yang, Yao; Yuan, Zhaohui; Lin, Xiaofeng

    2016-01-01

    Purpose To elucidate the Chinese practice of intraocular antibiotics administration for prophylaxis after open globe injury. Methods A cross-sectional questionnaire survey was performed online by scanning a Quickmark (QR) code with smartphones at the 20th Chinese National Conference of Ocular Trauma in November 2014. Results A total of 153 (30.6%) of all participators at the conference responded. Of the respondents, 20.9% were routinely administered with prophylactic intraocular injection of antibiotics at the conclusion of the primary eye repair, and 56.9% were used only in cases with high risk of endophthalmitis development. The intraocular route of delivery was mainly included with intracameral injection (47.9%) and intravitreal injection (42.0%). Cephalosporins (53.8%) and vancomycin (42.0%) were the main choices of antibiotic agents, followed by fluoroquinolones (24.3%), and aminoglycosides (13.4%). Only 21.9% preferred a combination of two or more two drugs routinely. In addition, significantly more respondents from the referral eye hospital (92.7%) replied using intraocular antibiotics injection for prophylaxis compared to those respondents from the primary hospital (69.4%) (p = 0.001, Fisher’s exact test). Conclusions Intraocular antibiotics injection for post-traumatic endophthalmitis prophylaxis is widely used in China. However, the choice of antibiotic agents and the intraocular route of delivery vary. A well-designed clinical trial is needed to establish a standardized protocol of intraocular antibiotics administration for post-traumatic endophthalmitis prophylaxis. PMID:27275777

  20. Survey of Intraocular Antibiotics Prophylaxis Practice after Open Globe Injury in China.

    Directory of Open Access Journals (Sweden)

    Bingsheng Lou

    Full Text Available To elucidate the Chinese practice of intraocular antibiotics administration for prophylaxis after open globe injury.A cross-sectional questionnaire survey was performed online by scanning a Quickmark (QR code with smartphones at the 20th Chinese National Conference of Ocular Trauma in November 2014.A total of 153 (30.6% of all participators at the conference responded. Of the respondents, 20.9% were routinely administered with prophylactic intraocular injection of antibiotics at the conclusion of the primary eye repair, and 56.9% were used only in cases with high risk of endophthalmitis development. The intraocular route of delivery was mainly included with intracameral injection (47.9% and intravitreal injection (42.0%. Cephalosporins (53.8% and vancomycin (42.0% were the main choices of antibiotic agents, followed by fluoroquinolones (24.3%, and aminoglycosides (13.4%. Only 21.9% preferred a combination of two or more two drugs routinely. In addition, significantly more respondents from the referral eye hospital (92.7% replied using intraocular antibiotics injection for prophylaxis compared to those respondents from the primary hospital (69.4% (p = 0.001, Fisher's exact test.Intraocular antibiotics injection for post-traumatic endophthalmitis prophylaxis is widely used in China. However, the choice of antibiotic agents and the intraocular route of delivery vary. A well-designed clinical trial is needed to establish a standardized protocol of intraocular antibiotics administration for post-traumatic endophthalmitis prophylaxis.

  1. A new device to noninvasively estimate the intraocular pressure produced during ocular compression

    Directory of Open Access Journals (Sweden)

    Korenfeld MS

    2016-01-01

    Full Text Available Michael S Korenfeld,1,2 David K Dueker3 1Comprehensive Eye Care, Ltd., 2Department of Ophthalmology and Visual Sciences, Washington University, Washington, MO, USA; 3Hamad Medical Corporation, Doha, Qatar Purpose: To describe a noninvasive instrument that estimates intraocular pressure during episodes of external globe compression and to demonstrate the accuracy and reliability of this device by comparing it to the intraocular pressures simultaneously and manometrically measured in cannulated eyes. Methods: A thin fluid-filled bladder was constructed from flexible and inelastic plastic sheeting and was connected to a pressure transducer with high pressure tubing. The output of the pressure transducer was sent to an amplifier and recorded. This device was validated by measuring induced pressure in the fluid-filled bladder while digital pressure was applied to one surface, and the other surface was placed directly against a human cadaver eye or in vivo pig eye. The human cadaver and in vivo pig eyes were each cannulated to provide a manometric intraocular pressure control. Results: The measurements obtained with the newly described device were within ~5% of simultaneously measured manometric intraocular pressures in both a human cadaver and in vivo pig eye model for a pressure range of ~15–100 mmHg. Conclusion: This novel noninvasive device is useful for estimating the intraocular pressure transients induced during any form of external globe compression; this is a clinical setting where no other devices can be used to estimate intraocular pressure. Keywords: glaucoma, intraocular pressure, tonometer, ocular compression

  2. Trends in Artificial Intelligence.

    Science.gov (United States)

    Hayes, Patrick

    1978-01-01

    Discusses the foundations of artificial intelligence as a science and the types of answers that may be given to the question, "What is intelligence?" The paradigms of artificial intelligence and general systems theory are compared. (Author/VT)

  3. Artificial Inteligence and Law

    OpenAIRE

    Fuková, Kateřina

    2012-01-01

    Submitted diploma work Artificial Intelligence and Law deals with the rule of law and its position in the process of new advanced technologies in computer cybernetics and further scientific disciplines related with artificial intelligence and its creation. The first part of the work introduces the history of the first imagines about artificial intelligence and concerns with its birth. This chapter presents main theoretical knowledge and hypotheses defined artificial intelligence and progre...

  4. Magnetic resonance imaging diagnosis of intraocular lenses. Die kernspintomographische Diagnostik der Hinterkammerlinse

    Energy Technology Data Exchange (ETDEWEB)

    Tosch, U. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany)); Bleckmann, H. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany)); Kaczmarek, U. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany))

    1994-09-01

    Intraocular lenses were investigated by MRI to obtain information about the quality of this method. In experimental studies, seven lenses of between 0 and 30 diopters were visualized. By MRI it was possible to differentiate the various diameters of lenses. It was not possible to discriminate the material of the intraocular lenses. After these first studies the eyes of two corpses and eight patients were investigated. Because of the resolution of MRI it was possible to tell the diopter of implanted lenses. However, by use of MRI in the regular position, a tilting or decentration of the intraocular lens was demonstrated. (orig.)

  5. Optical quality of toric intraocular lens implantation in cataract surgery

    Institute of Scientific and Technical Information of China (English)

    Xian-Wen; Xiao; Jing; Hao; Hong; Zhang; Fang; Tian

    2015-01-01

    AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of Acry Sof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes,T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), residual refractive cylinder and intraocular lens(IOL) axis rotation.Objective optical quality were measured using optical quality analysis system(OQAS Ⅱ, Visiometrics, Spain),included the cutoff frequency of modulation transfer function(MTFcutoff), objective scattering index(OSI),Strehl ratio, optical quality analysis system value(OV)100%, OV 20% and OV 9% [the optical quality analysis system(OQAS) values at contrasts of 100%, 20%, and 9%].RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18 ±0.11 and 0.07 ±0.08 log MAR; the mean residual refractive cylinder was 0.50 ±0.29 D; the mean toric IOL axis rotation was 3.62 ±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV9% were 22.862 ±5.584, 1.80 ±0.84, 0.155 ±0.038, 0.76 ±0.18,0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%,OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different(P >0.05), except the residual refractive cylinder(P <0.05).CONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of Acry Sof toric IOL implantation. Implantation of an Acry Sof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery.

  6. Change in Intraocular Pressure During Point-of-Care Ultrasound

    Directory of Open Access Journals (Sweden)

    Berg, Cameron

    2015-03-01

    Full Text Available Introduction: Point-of-care ocular ultrasound (US is a valuable tool for the evaluation of traumatic ocular injuries. Conventionally, any maneuver that may increase intraocular pressure (IOP is relatively contraindicated in the setting of globe rupture. Some authors have cautioned against the use of US in these scenarios because of a theoretical concern that an US examination may cause or exacerbate the extrusion of intraocular contents. This study set out to investigate whether ocular US affects IOP. The secondary objective was to validate the intraocular pressure measurements obtained with the Diaton® as compared with standard applanation techniques (the Tono-Pen®.   Methods: We enrolled a convenience sample of healthy adult volunteers. We obtained the baseline IOP for each patient by using a transpalpebral tonometer. Ocular US was then performed on each subject using a high-frequency linear array transducer, and a second IOP was obtained during the US examination. A third IOP measurement was obtained following the completion of the US examination. To validate transpalpebral measurement, a subset of subjects also underwent traditional transcorneal applanation tonometry prior to the US examination as a baseline measurement. In a subset of 10 patients, we obtained baseline pre-ultrasound IOP measurements with the Diaton® and Tono-Pen®, and then compared them.   Results: The study included 40 subjects. IOP values during ocular US examination were slightly greater than baseline (average +1.8mmHg, p=0.01. Post-US examination IOP values were not significantly different than baseline (average -0.15mmHg, p=0.42. In a subset of 10 subjects, IOP values were not significantly different between transpalpebral and transcorneal tonometry (average +0.03mmHg, p=0.07.   Conclusion: In healthy volunteer subjects, point-of-care ocular US causes a small and transient increase in IOP. We also showed no difference between the Diaton® and Tono-Pen® methods

  7. Tilt and decentration tolerance of intraocular lenses: measurements with an improved mechanical model eye

    Science.gov (United States)

    Traxler, Lukas; Reutterer, Bernd; Bayer, Natascha; Rank, Elisabet; Krause, Sylvio; Beckert, Erik; Drauschke, Andreas

    2016-03-01

    Cataract, a clouding of the crystalline eye lens, is the leading cause of blindness. It can effectively be treated by cataract surgery, where the clouded lens is replaced by an artificial intraocular lens (IOL). Postoperative healing processes can cause a displacement of the IOL, which further leads to the fact that the quality of vision is deteriorated. Studies have shown that the imaging quality of high sophisticated IOL designs is more sensitive to lens displacements than simpler designs. The effects of IOL displacements are not well represented and tested within the current IOL test standard ISO 11979-2. This fact leads to the necessity to develope new test standards for novel and more sophisticated IOL designs. In this paper we present an improved model eye, which extends the current standard in three main aspects: First, the eye-model is very close to the physiology of the human eye. Second, electromechanic drives allow an automatic and precise simulation of postoperative lens tilts and decentrations, and finally in addition to standard conform MTF analysis, in the proposed setup also wavefront aberrations are measured. The latter reveals specific image aberrations caused by lens displacements. The model eye allows to objectively analyze the displacement tolerance of various IOL designs. The functionality of this novel setup is tested by measuring a spherical and an aspheric IOL design. Additionally, for comparison, IOLs that were already investigated with a previous version of the presented model eye are used for analysis. Measurements results reveal improvements compared to the previous version of the model eye and a functional prototype for wavefront measurement.

  8. Opacificação tardia de lente intra-ocular de polimetilmetacrilato (PMMA: relato de caso Late opacification of a polymethylmethacrylate (PMMA intraocular lens: case report

    Directory of Open Access Journals (Sweden)

    Otacílio de Oliveira Maia Júnior

    2005-10-01

    Full Text Available O implante das lentes intra-oculares foi grande avanço na reabilitação visual de pacientes submetidos à cirurgia de extração da catarata. Contudo, os materiais utilizados na fabricação destas lentes, apesar de terem boa biocompatibilidade, são passíveis de alterações posteriores ao implante. No presente estudo, os autores relatam um caso raro de opacificação tardia de lente de polimetilmetacrilato, material inerte e bem tolerado intra-ocularmente, discutindo aspectos importantes no manejo desta complicação, bem como indicação de explante e substituição da lente.The use of intraocular lenses was a great advance in visual recovery after cataract surgery. Although usually with good biocompatibility, some alterations in the intraocular lens material may occur after implantation. Polymethylmethacrylate was the first intraocular lens material to be used on a large scale and assumed to be inert and well-tolerated. We present a rare case of late opacification of a polymethylmethacrylate lens, discussing important aspects of its management such as the indication for intraocular lens exchange.

  9. Intraocular electro-optic lens with ciliary muscle controlled accommodation.

    Science.gov (United States)

    Doornaert, Dries; Glorieux, Christ; De Gersem, Herbert; Puers, Robert; Spileers, Werner; Blanckaert, Johan

    2013-01-01

    In this paper a concept is proposed of an intraocular lens implant with electro-optic accommodation of a variable-focus hybrid liquid-crystal-based lens. The dioptric strength of the lens is electronically controlled by a signal that is derived from the change of inductance of a sensing coil due to a marker implanted in the nearby contracting or decontracting ciliary muscle. Analytical, numerical and experimental results are reported on the dependency of the frequency of a Colpitts oscillator circuit on the location of a nearby conductive marker. A concept is also reported on the use as an electro-optic lens of a device based on a liquid crystal in planar alignment, which is held between a flat and a curved window coated with optically transparent and electrically conductive layers. PMID:24110406

  10. Laboratory analyses of two explanted hydrophobic acrylic intraocular lenses

    Directory of Open Access Journals (Sweden)

    Yunhai Dai

    2014-01-01

    Full Text Available Two three-piece hydrophobic acrylic intraocular lenses (IOLs were explanted from two patients at 7 and 9 years, respectively, after implantation, because of poor fundus visualisation and/or a clinically significant decrease in visual acuity related to their opacified IOLs. In addition to light microscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy, confocal laser scanning microscopy was used for the first time to observe the explanted IOLs. The clinical aspect seemed to correspond to the phenomenon of surface light scattering, while laboratory analyses showed dense glistenings in the central layer of the IOL optic, which had no change next to the surface. Further studies on these phenomena are needed.

  11. Ectopic intraocular lens: An unusual complication of cataract surgery

    Directory of Open Access Journals (Sweden)

    Mehul A Shah

    2014-01-01

    Full Text Available We wish to report an unusual complication of intraocular lens (IOL insertion following uneventful phacoemulsification. After successful phacoemulsification surgery, a hydrophobic acrylic IOL was loaded in the injector for insertion into the capsular bag. During insertion, the IOL inadvertently extended into the corneal stromal lamella. The complication was recognized at a late stage, and the foldable acrylic lens was retrieved and reinserted correctly in the bag. The anterior chamber was made viscoelastically taut and was maintained in this state for 10 min, followed by a routine viscoelastic wash and air bubble injection. Cornea was slightly edematous with stromal haze, and the corneal thickness was 908 μm. At the 1-month follow-up visit, the patient′s vision was 20/40, the stromal haze had subsided, the corneal thickness was 572 μm, and the patient was comfortable. Though it was unknown complication, following proper management patient recovered satisfactorily.

  12. Central corneal thickness and intraocular pressure in premature infants.

    Science.gov (United States)

    Sekeroglu, Mehmet Ali; Hekimoglu, Emre; Petricli, İkbal Seza; Karakaya, Jale; Ozcan, Beyza; Yucel, Husniye; Kavurt, Aysen Sumru; Bas, Ahmet Yagmur

    2015-12-01

    To evaluate the central corneal thickness (CCT) and intraocular pressure (IOP) of premature infants and to document correlation of them with gestational age, chronological age, and birth weight of infants. Using a hand-held applanation tonometer and a portable pachymeter, IOP and CCT of 170 premature infants were measured just before initial retinopathy of prematurity screening examination and re-measured 4 weeks after the first visit. The CCT and IOP were positively correlated during the first (r = 0.616, p premature infants with a smaller gestational age were found to be higher (p Premature infants with smaller gestational age have higher CCT and IOP values when compared to older infants. These values tend to become lower 4 weeks after the first examination as infants become older. The CCT and IOP were positively correlated with each other and both were negatively correlated with gestational age, chronological age, and birth weight during first and second visits. PMID:26286757

  13. Bionic intraocular lens with variable focus and integrated structure

    Science.gov (United States)

    Liang, Dan; Wang, Xuan-Yin; Du, Jia-Wei; Xiang, Ke

    2015-10-01

    This paper proposes a bionic accommodating intraocular lens (IOL) for ophthalmic surgery. The designed lens has a solid-liquid mixed integrated structure, which mainly consists of a support ring, elastic membrane, rigid lens, and optical liquid. The lens focus can be adjusted through the deformation of the lens front surface when compressed. The integrated structure of the IOL is presented, as well as a detailed description of the lens materials and fabrication process. Images under different radial pressures are captured, and the lens deformation process, accommodating range, density, and optical property are analyzed. The designed lens achieves a 14.6 D accommodating range under a radial pressure of 51.4 mN and a 0.24 mm alteration of the lens outer radius. The deformation property of the lens matches well with the characteristic of the eye and shows the potential to help patients fully recover their vision accommodation ability after the cataract surgery.

  14. [To guard against mistakes in selection of intraocular lenses].

    Science.gov (United States)

    He, Shou-zhi

    2008-04-01

    Development of different kinds of new intraocular lenses (IOL) provide more selections to meet various clinical requirements, which may plays an active role in making cataract surgery more perfectible. But there are many misunderstandings about how to select the proper IOL. For example, "the expensive one is the best one", "new product is absolutely perfect", and so on. Some surgeons prefer more practice and ignore the summary of the experiences. Someone unilaterally exaggerates some special function of IOL When selecting the IOL, it is a common challenge for us to fully consider the patients needs, and properly manage the relationship between the basic need and special need, and to avoid fanaticism, and provide the best benefits to the patients. PMID:18844010

  15. The accute effects of resistance exercise on intraocular pressure

    Directory of Open Access Journals (Sweden)

    Vieira Geraldo Magela

    2003-01-01

    Full Text Available PURPOSE: To study intraocular pressure (IOP variations in healthy volunteers after weight lifting, in the supine position. METHODS: A descriptive study was designed. Thirty-four individuals were preselected for this study, and a group of 25 volunteers fulfilled the inclusion criteria for joining the initial phase of this research. All of them were healthy without glaucoma. They were asked to lift an 85% top load in the supine position for 8 times. IOP was measured before and after the exercise. Student's t test was used to analyze the IOP variations. RESULTS: A small, but significant IOP decrease (1.61 mmHg was obtained after exposing 25 individuals (49 eyes to a specific physical effort. CONCLUSIONS: After a session of weight lifting in the supine position with 85% top load for 8 repetitions, there is a small, but significant IOP decrease.

  16. Intraocular penetration of sequentially instilled topical moxifloxacin, gatifloxacin, and levofloxacin

    Directory of Open Access Journals (Sweden)

    Koji Sugioka

    2009-10-01

    Full Text Available Koji Sugioka1, Masahiko Fukuda1, Shohei Komoto1, Motoki Itahashi1, Masakazu Yamada2, Yoshikazu Shimomura11Department of Ophthalmology, Kinki University School of Medicine, Osaka-Sayama City, Osaka, Japan; 2Division for Vision Research, National Institute of Sensory Organs, National Tokyo Medical Center, Tokyo, JapanPurpose: The objective of the study was to compare the intraocular penetration levels of the newer fluoroquinolones, moxifloxacin, gatifloxacin, and levofloxacin in the rabbit’s cornea, aqueous humor, and conjunctiva after topical instillation.Methods: 0.5% moxifloxacin, 0.3% gatifloxacin, and 0.5% levofloxacin were instilled in random sequence in both eyes of nine New Zealand White rabbits at two-minute intervals. Instillation was repeated every 15 minutes for a total of three drops of each fluoroquinolone per eye. Three additional animals had only moxifloxacin instilled bilaterally using the same schedule. Sixty minutes after the final instillation, the rabbits were sacrificed for determination of corneal, aqueous humor, and conjunctival fluoroquinolone concentrations using highperformance liquid chromatography.Results: Moxifloxacin achieved significantly higher concentrations than levofloxacin and gatifloxacin in the cornea (P = 0.0102 and P = 0.0006, respectively, aqueous humor (P = 0.0015 and P < 0.0001, respectively, and conjunctiva (P = 0.0191 and P = 0.0236, respectively. Conclusions: 0.5% moxifloxacin eyedrops provided superior intraocular penetration in rabbits’ eyes compared with the two other fluoroquinolones, 0.5% levofloxacin and 0.3% gatifloxacin.Keywords: fluoroquinolone, gatifloxacin, levofloxacin, moxifloxacin, penetration, rabbit

  17. A previsibilidade biométrica nas lentes intra-oculares multifocais Biometric predictability in multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Augusto Cézar Lacava

    2007-08-01

    Full Text Available OBJETIVO: Apresentar a previsibilidade biométrica, avaliando a refração pós-operatória e acuidade visual (AV, em olhos submetidos a implante de lente intra-ocular multifocal. MÉTODOS: Estudo retrospectivo em 88 olhos de 50 pacientes, submetidos à facoemulsificação com implante de lentes multifocais, de três marcas comerciais ReSTOR, ReZoom e Tecnis. No exame biométrico foram utilizados a biometria óptica ou biometria por interferometria de baixa coerência, associada ao uso de tomógrafo de segmento anterior e à fórmula biométrica Holladay II. Com a refração pós-operatória, acuidade visual e a dioptria da LIO implantada, segundo a fórmula Holladay II, calculamos o valor da lente intra-ocular (LIO a ser implantada caso utilizássemos as fórmulas SRKT e Haigis. Os resultados foram avaliados por métodos estatísticos. RESULTADOS: Todos os olhos obtiveram AV igual ou maior a 20/40 e J3 sem correção. As fórmulas Holladay II, SRKT e Haigis apresentaram performance semelhante em todos os grupos de olhos. CONCLUSÃO: A utilização de novas tecnologias, como a biometria óptica e fórmulas de última geração, favorecem a obtenção do resultado refracional almejado com grande previsibilidade.PURPOSE: To present biometric predictability, evaluating postoperative refraction and visual acuity in eyes submitted to multifocal intraocular lens implantation. METHODS: Retrospective study in 88 eyes of 50 patients, submitted to phacoemulsification with multifocal lens implant of three commercial brands: ReSTOR, ReZoom and Tecnis. For biometric examination were used: optic biometry associated to the use of tomography of anterior segment and Holladay II biometric formula. With postoperative refraction, visual acuity and implanted IOL, according to Holladay II formula, we calculated the value of IOL to be implanted in case we used SRKT and Haigis formulas. The results were evaluated according to statistical methods. RESULTS: All eyes

  18. New Management of Malignant Glaucoma by Phacoemulsification with Posterior Chamber Foldable Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    GeJian; GuoY

    1999-01-01

    Objective:To investigate the feasibility of phacoemulsification with posterior chamber foldable intraocular lens implantation in the management of malignant glaucoma. Patients and Methods:Fourteen patients with malignant glaucoma diagnosed in the Department of Glaucoma were enrolled in the study.12 patients developed malignant glaucoma after filtration surgery.1 developed after peripheral iridectomy.1 patient developed malignant glaucoma without any clear cause.Cataract phacoemulsification was performed.Posterior chamber intraocular foldable lens was implanted in 10 cases of patients.Results:All 14 patients were cured wiht normal intraocular pressure,normal anterior chamber depth and increased visual acuity.Conclusion:Phacoemulsification with posterior chamber foldable intraocular lens implantation is a good alternative in treating malignant glaucoma.

  19. The Experimental Study on Implantation of Intraocular Lens in Different Animals

    Institute of Scientific and Technical Information of China (English)

    WANGGui-qin; PENGXiu-jun; GUHan-qing

    2004-01-01

    To prevent the complications in cataract surgeries, the eyes of rabbits and monkeys were implanted with intraocular lens for 360 days. Methods: The eyes of the rabbits were performed with phacoemulsification and soft intraocular lens implantation. The eyes of the monkeys were performed with extracapsular cataract extraction and hard intraocular lens implantation. Results: The postoperative reactions included corneal edema, anterior chamber exudation, posterior capsule opacification and so on. The complications in the eyes of the rabbits were more than that in the eyes of the monkeys. Conclusion: The different postoperative reactions happened in different animals. In clinical the choice of the operative method and intraocular lens depended on the case in order to acquire the best sight.

  20. Intraocular pressure-lowering effect of oral paracetamol and its in vitro corneal penetration properties

    OpenAIRE

    Mohamed N; Meyer D

    2013-01-01

    Nabiel Mohamed, David MeyerDivision of Ophthalmology, Faculty of Medicine and Health Sciences, University of Stellenbosch, Cape Town, South AfricaBackground: Several studies have confirmed the ability of cannabinoids to reduce intraocular pressure. Experimental data recently demonstrated unequivocally that the analgesic effect of paracetamol is due to its indirect action on cannabinoid receptors. The question then arises as to whether paracetamol can reduce intraocular pressure via its effect...

  1. New two-point scleral-fixation technique for foldable intraocular lenses with four hollow haptics.

    Science.gov (United States)

    Liu, He-Ting; Jiang, Zheng-Xuan; Tao, Li-Ming

    2016-01-01

    The study was to report a new two-point scleral-fixation technique for foldable intraocular lenses with four haptics. Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera flaps at two opposite points. The postoperative best-corrected visual acuities (BCVAs) of all patients were significantly better than their preoperative BCVA. The results demonstrate that two-point, scleral fixations of foldable, intraocular lenses might be practicable and effective.

  2. Followup of a Dog with an Intraocular Silicone Prosthesis Combined with an Extraocular Glass Prosthesis

    OpenAIRE

    Gwendolyna Romkes; Johanna Corinna Eule

    2012-01-01

    Because of unpredictable corneal changes, evisceration and implantation of a silicone prosthesis does not always lead to a satisfying cosmetic result. This paper describes the use of an intraocular silicone prosthesis in combination with an extraocular glass prosthesis and shows a followup of two and a half years in a nonexperimental study. An intraocular silicone prosthesis was implanted after evisceration of the left eye in a five-month-old Bernese mountain dog. A glass prosthesis was fitte...

  3. A new device to noninvasively estimate the intraocular pressure produced during ocular compression

    OpenAIRE

    Korenfeld MS; Dueker DK

    2016-01-01

    Michael S Korenfeld,1,2 David K Dueker3 1Comprehensive Eye Care, Ltd., 2Department of Ophthalmology and Visual Sciences, Washington University, Washington, MO, USA; 3Hamad Medical Corporation, Doha, Qatar Purpose: To describe a noninvasive instrument that estimates intraocular pressure during episodes of external globe compression and to demonstrate the accuracy and reliability of this device by comparing it to the intraocular pressures simultaneously and manometrically measured in cannulat...

  4. Intraocular Foreign Body. A Case Presentation Cuerpo extraño intraocular. Presentación de un caso

    Directory of Open Access Journals (Sweden)

    Inés Zamora Galindo

    2012-05-01

    Full Text Available

    Eye trauma is a common cause of visual impairment, mainly of monocular blindness in 33 to 40% of cases. The case of a 40 years old female patient of rural origin, who attended Ophthalmology consultation at the Dr. Gustavo Aldereguía Lima General University Hospital because of blurry vision in her right eye three months after a trauma, is presented. An accurate medical record, ophthalmologic examination and appropriate diagnostic methods allowed identifying an intraocular foreign body. The patient underwent surgery and evolved favorably. Her best corrected visual acuity is 0.7 in the right eye and 1.0 in the left eye.

    Los traumatismos oculares son una causa común de deficiencia visual, principalmente de ceguera monocular en el 33 al 40 % de los casos. Se presenta el caso de un paciente de 40 años y procedencia rural, que acudió a consulta de Oftalmología del Hospital General Universitario Dr. Gustavo Aldereguía Lima por presentar visión borrosa del ojo derecho, tres meses después de haber sufrido un traumatismo. Una correcta anamnesis, examen oftalmológico y métodos diagnósticos adecuados lograron la identificación de un cuerpo extraño intraocular. El paciente fue sometido a cirugía y evolucionó favorablemente; su agudeza visual mejor corregida es de 0,7 en el ojo derecho y de 1,0 en el izquierdo.

  5. Intraocular pressure variations during zygomatic fracture reduction and fixation: a clinical study.

    LENUS (Irish Health Repository)

    Murray, Dylan J

    2012-02-03

    BACKGROUND: The reduction of midface fractures has been associated with the rare but devastating complication of blindness. An increase in intraocular pressure is important in the mechanism of blindness in this setting. In this study, the authors assessed the intraocular pressure in patients who underwent zygomatic fracture reduction (with or without fixation). METHODS: Using applanation tonometry, 29 patients underwent intraocular pressure measurements before, during, and after fracture fixation. The contralateral pressures were measured and used as the control. RESULTS: There were 29 patients with a mean age of 35 years, and the mean time to surgery was 5 days. Preoperatively, all patients had normal intraocular pressures and normal visual acuity. All patients underwent a Gillies lift and 18 patients required open reduction and fixation of the frontozygomatic suture (n = 4) or the infraorbital margin (n = 2), and the remainder (n = 12) required fixation of both points. There was no statistically significant increase in the intraocular pressures following the reduction of uncomplicated zygomatic fractures. Statistically significant pressure reductions were noted immediately after reduction and fixation. CONCLUSIONS: The surgical reduction of uncomplicated zygomatic fractures has no adverse effect on the intraocular pressure. It is the authors\\' opinion that adjunctive measures to reduce the pressures are unnecessary.

  6. A case of Alagille syndrome complicated by intraocular lens subluxation and rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Fukumoto M

    2013-07-01

    Full Text Available Masanori Fukumoto, Tsunehiko Ikeda, Tetsuya Sugiyama, Mari Ueki, Takaki Sato, Eisuke Ishizaki Department of Ophthalmology, Osaka Medical College, Takatsuki City, Japan Abstract: This case report describes a case of Alagille syndrome with developing intraocular lens subluxation and rhegmatogenous retinal detachment 4 years after cataract surgery. A 15-year-old female patient with Alagille syndrome-associated cataracts in both eyes underwent phacoemulsification aspiration and intraocular lens implantation. Four years postoperative, intraocular lens subluxation developed in her left eye. For treatment, extraction of the dislocated intraocular lens, anterior vitrectomy, and intraocular lens fixation was performed. Three weeks later, the patient developed rhegmatogenous retinal detachment, which was well-treated by pars plana vitrectomy. Cataract surgery needs to be performed carefully in patients with Alagille syndrome due to the weakness of the zonule of Zinn. Careful postoperative observation is necessary for patients with Alagille syndrome who have undergone intraocular surgery in order to facilitate early detection of a possible rhegmatogenous retinal detachment. Keywords: Alagille syndrome, cataract, retina, surgery

  7. Activation of autophagy in a rat model of retinal ischemia following high intraocular pressure.

    Directory of Open Access Journals (Sweden)

    Antonio Piras

    Full Text Available Acute primary open angle glaucoma is an optic neuropathy characterized by the elevation of intraocular pressure, which causes retinal ischemia and neuronal death. Rat ischemia/reperfusion enhances endocytosis of both horseradish peroxidase (HRP or fluorescent dextran into ganglion cell layer (GCL neurons 24 h after the insult. We investigated the activation of autophagy in GCL-neurons following ischemia/reperfusion, using acid phosphatase (AP histochemistry and immunofluorescence against LC3 and LAMP1. Retinal I/R lead to the appearance of AP-positive granules and LAMP1-positive vesicles 12 and 24 h after the insult, and LC3 labelling at 24 h, and induced a consistent retinal neuron death. At 48 h the retina was negative for autophagic markers. In addition, Western Blot analysis revealed an increase of LC3 levels after damage: the increase in the conjugated, LC3-II isoform is suggestive of autophagic activity. Inhibition of autophagy by 3-methyladenine partially prevented death of neurons and reduces apoptotic markers, 24 h post-lesion. The number of neurons in the GCL decreased significantly following I/R (I/R 12.21±1.13 vs controls 19.23±1.12 cells/500 µm; this decrease was partially prevented by 3-methyladenine (17.08±1.42 cells/500 µm, which potently inhibits maturation of autophagosomes. Treatment also prevented the increase in glial fibrillary acid protein immunoreactivity elicited by I/R. Therefore, targeting autophagy could represent a novel and promising treatment for glaucoma and retinal ischemia.

  8. Classification of intraocular lens and its intraocular biocompatibility%人工晶体分类及其在眼内的生物相容性

    Institute of Scientific and Technical Information of China (English)

    胡莉群

    2009-01-01

    目的:通过手术摘除自身浑浊晶体,植入人工晶体是治疗白内障的惟一有效措施.文章总结人工晶体材料的研究进展,为今后的临床应用和研究提供参考.方法:应用计算机检索1997/2009 Medline数据库、中国期刊网和万方数据库、SpringerLink数据库和ScienceDirect数据库.结果:共有25篇文章符合纳入标准.文章主要从人工晶体的发展现状、分类、生物相容性、人工晶体的并发症和发展趋势进行阐述.人工晶体按照硬度,可以分为硬质人工晶体和软性人工晶体.丙烯酸人工晶体比硅凝胶人工晶体的生物相容性更好.人工晶状体脱位是白内障摘除联合人工晶状体植入术后较常见的并发症之一.注入式人工晶体材料是今后研究的方向.结论:人工晶体植入眼内作为一种异物,机体对此产生反应是机体正常的防御现象.人工晶体材料和设计应充分的考虑人工晶体的生物相容性、术后视功能、调节功能、光保护等方面性能.保证术后的疗效和减少并发症的发生,使白内障患者获得更高质量的视力康复.%OBJECTIVE: The sole effective measure for cataract is replaced the epinephelos lens with intraocular lens. So, in this paper, we summarize the research process of intraocular lens, which can provide a reference for further study. METHODS: Medline, China Journal Net, Wanfang Data, SpringerLink, and ScienceDirect database were computer retrieved from 1997 to 2009. RESULTS: A total of 25 papers were included. All the papers were explained intraocular lens from the aspect of current situation, complication following implantation, and develop tendency. According to hardness, intraocular lens can be divided into hard intraocular lens and soft intraocular lens. Acrylic intraocular lenses showed better biocompatibility than the silicone intraocular lenses. In addition, the common complication following implantation was dislocation of lens. Therefore

  9. Comparison of dose calculation methods for brachytherapy of intraocular tumors

    Energy Technology Data Exchange (ETDEWEB)

    Rivard, Mark J.; Chiu-Tsao, Sou-Tung; Finger, Paul T.; Meigooni, Ali S.; Melhus, Christopher S.; Mourtada, Firas; Napolitano, Mary E.; Rogers, D. W. O.; Thomson, Rowan M.; Nath, Ravinder [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Quality MediPhys LLC, Denville, New Jersey 07834 (United States); New York Eye Cancer Center, New York, New York 10065 (United States); Department of Radiation Oncology, Comprehensive Cancer Center of Nevada, Las Vegas, Nevada 89169 (United States); Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Department of Radiation Physics, University of Texas, M.D. Anderson Cancer Center, Houston, Texas 77030 (United States) and Department of Experimental Diagnostic Imaging, University of Texas, M.D. Anderson Cancer Center, Houston, Texas 77030 (United States); Physics, Elekta Inc., Norcross, Georgia 30092 (United States); Department of Physics, Carleton University, Ottawa, Ontario K1S 5B6 (Canada); Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 06520 (United States)

    2011-01-15

    Purpose: To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using {sup 125}I or {sup 103}Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). Methods: Three clinical brachytherapy TPS capable of intraocular brachytherapy treatment planning and two MC codes were compared. The TPS investigated were Pinnacle v8.0dp1, BrachyVision v8.1, and Plaque Simulator v5.3.9, all of which use the AAPM TG-43 formalism in water. The Plaque Simulator software can also handle some correction factors from MC simulations. The MC codes used are MCNP5 v1.40 and BrachyDose/EGSnrc. Using these TPS and MC codes, three types of calculations were performed: homogeneous medium with point sources (for the TPS only, using the 1D TG-43 dose calculation formalism); homogeneous medium with line sources (TPS with 2D TG-43 dose calculation formalism and MC codes); and plaque heterogeneity-corrected line sources (Plaque Simulator with modified 2D TG-43 dose calculation formalism and MC codes). Comparisons were made of doses calculated at points-of-interest on the plaque central-axis and at off-axis points of clinical interest within a standardized model of the right eye. Results: For the homogeneous water medium case, agreement was within {approx}2% for the point- and line-source models when comparing between TPS and between TPS and MC codes, respectively. For the heterogeneous medium case, dose differences (as calculated using the MC codes and Plaque Simulator) differ by up to 37% on the central-axis in comparison to the homogeneous water calculations. A prescription dose of 85 Gy at 5 mm depth based on calculations in a homogeneous medium delivers 76 Gy and 67 Gy for specific {sup 125}I and {sup 103}Pd sources, respectively, when accounting for COMS-plaque heterogeneities. For off

  10. Anticipatory Artificial Autopoiesis

    OpenAIRE

    DuBois, Daniel; Holmberg, Stig C.

    2010-01-01

    In examining relationships between autopoiesis and anticipation in artificial life (Alife) systems it is demonstrated that anticipation may increase efficiency and viability in artificial autopoietic living systems. This paper, firstly, gives a review of the Varela et al [1974] automata algorithm of an autopoietic living cell. Some problems in this algorithm must be corrected. Secondly, a new and original anticipatory artificial autopoiesis algorithm for automata is presented. ...

  11. Inteligencia artificial en vehiculo

    OpenAIRE

    Amador Díaz, Pedro

    2012-01-01

    Desarrollo de un robot seguidor de líneas, en el que se implementan diversas soluciones de las áreas de sistemas embebidos e inteligencia artificial. Desenvolupament d'un robot seguidor de línies, en el qual s'implementen diverses solucions de les àrees de sistemes encastats i intel·ligència artificial. Follower robot development of lines, in which various solutions are implemented in the areas of artificial intelligence embedded systems.

  12. Artificial cognition architectures

    CERN Document Server

    Crowder, James A; Friess, Shelli A

    2013-01-01

    The goal of this book is to establish the foundation, principles, theory, and concepts that are the backbone of real, autonomous Artificial Intelligence. Presented here are some basic human intelligence concepts framed for Artificial Intelligence systems. These include concepts like Metacognition and Metamemory, along with architectural constructs for Artificial Intelligence versions of human brain functions like the prefrontal cortex. Also presented are possible hardware and software architectures that lend themselves to learning, reasoning, and self-evolution

  13. National Elevation Dataset (NED)

    Data.gov (United States)

    Kansas Data Access and Support Center — The U.S. Geological Survey has developed a National Elevation Database (NED). The NED is a seamless mosaic of best-available elevation data. The 7.5-minute...

  14. Iowa Bedrock Surface Elevation

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — This Digital Elevation Model (DEM) of the bedrock surface elevation in Iowa was compiled using all available data, principally information from GEOSAM, supplemented...

  15. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Directory of Open Access Journals (Sweden)

    Paschalis EI

    2014-01-01

    Full Text Available Eleftherios I Paschalis,* Fabiano Cade,* Samir Melki, Louis R Pasquale, Claes H Dohlman, Joseph B CiolinoMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA*These authors contributed equally to this workPurpose: To present an autonomous intraocular pressure (IOP measurement technique using a wireless implantable transducer (WIT and a motion sensor.Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline IOP.Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg and mean vehicle IOP (13.27±2.1 mmHg (P=0.45, suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001, and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001. Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001. Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute, during which the IOP is not expected to change.Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.Keywords: IOP, pressure transducer, wireless, MEMS, implant, intraocular

  16. Clinical study of customized aspherical intraocular lens implants

    Institute of Scientific and Technical Information of China (English)

    Lie-Xi; Jia; Zhao-Hui; Li

    2014-01-01

    AIM:To compare if there is an improvement in visual functions with age-related cataracts between patients receiving a aspherical intraocular lens(IOL) based on corneal wavefront aberration and patients randomly assigned lenses.METHODS:A total of 124 eyes of 124 patients with age-related cataracts were placed in experimental group and a group receiving randomly assigned(RA) lenses.The experimental group was undergone Pentacam corneal spherical aberration measurement before surgery; the targeted range for residual total spherical aberration after surgery was set to 0-0.3 μm. Patients with a corneal spherical aberration <0.3 μm were implanted with a zero-spherical aberration advanced optics(AO) aspherical IOL and patients with an aberration ≥0.3 μm received a Tecnis Z9003 aspherical lens in experimental group. RA patients were randomly implanted with an AO lens or a Tecnis Z9003 lens. Three months after surgery total spherical aberration, photopic/mesopic contrast sensitivities, photopic/mesopic with glare contrast sensitivities, and logMAR vision were measured.RESULTS:Statistical analysis on logMAR vision showed no significant difference between two groups(P =0.413). The post-surgical total spherical aberration was 0.126 ±0.097 μm and 0.152 ±0.151 μm in the experimental and RA groups, respectively(P =0.12). The mesopic contrast sensitivities at spatial frequencies of 6,12 and 18 c/d in the experimental group were significantly higher than of the RA group(P =0.00; P =0.04;P =0.02). The mesopic with glare contrast sensitivity in the experimental group at a spatial frequency of 18 c/d was also significantly higher vs the RA group(P =0.01).CONCLUSION:Pre-surgical corneal spherical aberration measurement in cataract patients followed bycustomized selection of aspherical IOL implants improved mesopic contrast sensitivities at high spatial frequencies, and thus is a superior strategy compared to the random selection of aspherical intraocular lens implants.

  17. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-01-01

    Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = −0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type

  18. Resultados da troca de lente intra-ocular de hidrogel opacificada

    Directory of Open Access Journals (Sweden)

    Salera Cristina Moreira

    2004-01-01

    Full Text Available OBJETIVO: Avaliar os resultados da explantação e substituição das lentes intra-oculares (LIO de hidrogel opacificadas. MÉTODOS: Foram analisados retrospectivamente os prontuários de 12 pacientes (15 olhos submetidos à explantação e substituição das lentes intra-oculares de hidrogel opacificadas. RESULTADOS: A opacificação das lentes intra-oculares de hidrogel causou perdas de linhas de visão em 13 olhos (86,7%. A troca das lentes intra-oculares opacificadas promoveu o ganho de linhas de visão em 11 olhos (73,3%. As complicações peroperatórias ocorreram em três olhos (20% e foram as seguintes: perda de óleo de silicone, ruptura total de zônula com perda do saco capsular e ruptura parcial de zônula. Durante a explantação das lentes intra-oculares foi necessária a realização de incisões relaxantes na borda da capsulorrexe anterior em três olhos (20% e em dois olhos (13,3% os hápticos foram cortados sendo retirada somente a zona óptica das lentes intra-oculares. CONCLUSÃO: A cirurgia para explantação e substituição das lentes intra-oculares opacificadas mostrou-se eficaz naqueles pacientes com perdas de linhas de visão (p > 0,05.

  19. Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report

    Directory of Open Access Journals (Sweden)

    Kamiya Kazutaka

    2012-04-01

    Full Text Available Abstract Introduction We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. Case presentation A 53-year-old woman had undergone toric implantable collamer lens implantation three years earlier. After informed consent was obtained, we performed simultaneous toric implantable collamer lens removal and phacoemulsification with toric intraocular lens implantation. Preoperatively, the manifest refraction was 0, -0.5 × 15, with an uncorrected visual acuity of 0.7 and a best spectacle-corrected visual acuity of 0.8. Postoperatively, the manifest refraction was improved to 0, -0.5 × 180, with an uncorrected visual acuity of 1.2 and a best spectacle-corrected visual acuity of 1.5. No vision-threatening complications were observed. Conclusion Toric intraocular lens implantation may be a good surgical option for the correction of spherical and cylindrical errors in eyes with implantable collamer lens-induced cataract and astigmatism.

  20. Artificial life and life artificialization in Tron

    Directory of Open Access Journals (Sweden)

    Carolina Dantas Figueiredo

    2012-12-01

    Full Text Available Cinema constantly shows the struggle between the men and artificial intelligences. Fiction, and more specifically fiction films, lends itself to explore possibilities asking “what if?”. “What if”, in this case, is related to the eventual rebellion of artificial intelligences, theme explored in the movies Tron (1982 and Tron Legacy (2010 trat portray the conflict between programs and users. The present paper examines these films, observing particularly the possibility programs empowering. Finally, is briefly mentioned the concept of cyborg as a possibility of response to human concerns.

  1. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P.

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  2. Sulcus Fixation of Foldable Intraocular Lenses Guided by Ultrasound Biomicroscopy.

    Science.gov (United States)

    Gao, Shasha; Qin, Tingyu; Wang, Shengnan; Lu, Yong

    2015-01-01

    Background. To evaluate the clinical efficacy of suture fixation of foldable intraocular lens (IOL) in ciliary sulcus guided by ultrasound biomicroscopy (UBM). Methods. Thirty-five eyes of 32 cases needing suture fixation of foldable IOL in ciliary sulcus in our hospital were collected and divided into two groups: group A and group B. In group A, UBM was performed on 19 eyes of 17 cases before surgery to locate the projection position of ciliary sulcus in iris surface. In group B, the traditional sulcus fixation of IOL was performed on 16 eyes of 15 cases. The inserting position of needles, the haptics position of IOL and the IOL tilt, and decentration were observed by UBM examination 3 months after the surgery. Meanwhile, the vision and contrast sensitivity were analysed. Results. The differences in inserting position of the needle, the IOL tilt and decentration, the ratio of IOL haptics in sulcus, and uncorrected visual acuity were statistically significant (P 0.05). Conclusions. Sulcus fixation of foldable IOL aided by UBM can increase the accuracy of IOL haptics implanted into ciliary sulcus and reduce the IOL tilt and decentration.

  3. Aerobic exercise and intraocular pressure in normotensive and glaucoma patients

    Directory of Open Access Journals (Sweden)

    Chatzibalis Theodosios

    2009-08-01

    Full Text Available Abstract Background With the increasing number of people participating in physical aerobic exercise, jogging in particular, we considered that it would be worth knowing if there are should be limits to the exercise with regard to the intraocular pressure (IOP of the eyes. The purpose of this study is to check IOP in healthy and primary glaucoma patients after aerobic exercise. Methods 145 individuals were subdivided into seven groups: normotensives who exercised regularly (Group A; normotensives in whose right eye (RE timolol maleate 0.5% (Group B, latanoprost 0.005% (Group C, or brimonidine tartrate 0.2% (Group D was instilled; and primary glaucoma patients under monotherapy with β-blockers (Group E, prostaglandin analogues (Group F or combined antiglaucoma treatment (Group G instilled in both eyes. The IOP of both eyes was measured before and after exercise. Results A statistically significant decrease was found in IOP during jogging. The aerobic exercise reduces the IOP in those eyes where a b-blocker, a prostaglandin analogue or an α-agonist was previously instilled. The IOP is also decreased in glaucoma patients who are already under antiglaucoma treatment. Conclusion There is no ocular restriction for simple glaucoma patients in performing aerobic physical activity.

  4. Stem Cells in the Trabecular Meshwork for Regulating Intraocular Pressure.

    Science.gov (United States)

    Yun, Hongmin; Zhou, Yi; Wills, Andrew; Du, Yiqin

    2016-06-01

    Intraocular pressure (IOP) is still the main treatment target for glaucoma. Outflow resistance mainly exists at the trabecular meshwork (TM) outflow pathway, which is responsible for IOP regulation. Changes of TM cellularity and TM extracellular matrix turnover may play important roles in IOP regulation. In this article, we review basic anatomy and physiology of the outflow pathway and TM stem cell characteristics regarding the location, isolation, identification and function. TM stem cells are localized at the insert region of the TM and are label-retaining in vivo. They can be isolated by side-population cell sorting, cloning culture, or sphere culture. TM stem cells are multipotent with the ability to home to the TM region and differentiate into TM cells in vivo. Other stem cell types, such as adipose-derived stem cells, mesenchymal stem cells and induced pluripotent stem cells have been discovered for TM cell differentiation and TM regeneration. We also review glaucomatous animal models, which are suitable to study stem cell-based therapies for TM regeneration. PMID:27183473

  5. Effect of four different intraocular lenses on posterior capsule opacification

    Institute of Scientific and Technical Information of China (English)

    Rahmi; Duman; Fatih; Karel; Pelin; ?zyol; Can; Ates

    2015-01-01

    AIM: To evaluate the impact of 4 different intraocular lenses(IOLs) on posterior capsule opacification(PCO) by comparing the neodymium: yttrium-aluminum-garnet(Nd:YAG) laser capsulotomy rates.METHODS: This retrospective study included 4970 eyes of 4013 cataract patients who underwent phacoemulsification and IOL implantation between January 2000 and January 2008 by the same surgeon at one clinic. Four different IOLs were assessed. The outcome parameter was the incidence of Nd:YAG laser posterior capsulotomies.· RESULTS: An Nd:YAG laser posterior capsulotomy was performed in 153(3.07%) of the 4970 eyes. The mean follow-up time was 84 mo for all of the IOL groups. The percentage of eyes developing PCO was significantly greater for the acrylic hydrophilic IOLs than for the hydrophobic IOLs, although eyes with acrylic hydrophilic IOLs did not require Nd:YAG laser capsulotomy as soon as eyes with acrylic hydrophobic IOLs. There was no difference between the long-term PCO rates when 1-and 3-piece acrylic hydrophobic IOLs were compared or when IOLs made of the same material but with different haptic angles were compared.· CONCLUSION: In this study, eyes with acrylic hydrophilic IOLs were more likely to develop PCO than those with acrylic hydrophobic IOLs. The lens design(1-piece versus 3-piece and varying haptic angles) did not affect the PCO rate.

  6. Sulcus Fixation of Foldable Intraocular Lenses Guided by Ultrasound Biomicroscopy

    Directory of Open Access Journals (Sweden)

    Shasha Gao

    2015-01-01

    Full Text Available Background. To evaluate the clinical efficacy of suture fixation of foldable intraocular lens (IOL in ciliary sulcus guided by ultrasound biomicroscopy (UBM. Methods. Thirty-five eyes of 32 cases needing suture fixation of foldable IOL in ciliary sulcus in our hospital were collected and divided into two groups: group A and group B. In group A, UBM was performed on 19 eyes of 17 cases before surgery to locate the projection position of ciliary sulcus in iris surface. In group B, the traditional sulcus fixation of IOL was performed on 16 eyes of 15 cases. The inserting position of needles, the haptics position of IOL and the IOL tilt, and decentration were observed by UBM examination 3 months after the surgery. Meanwhile, the vision and contrast sensitivity were analysed. Results. The differences in inserting position of the needle, the IOL tilt and decentration, the ratio of IOL haptics in sulcus, and uncorrected visual acuity were statistically significant (P0.05. Conclusions. Sulcus fixation of foldable IOL aided by UBM can increase the accuracy of IOL haptics implanted into ciliary sulcus and reduce the IOL tilt and decentration.

  7. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Oriel Spierer

    2016-05-01

    Full Text Available A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  8. Reverse Optic Capture to Stabilize a Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Howard V. Gimbel

    2013-09-01

    Full Text Available Purpose: To describe a technique for stabilizing a rotationally unstable toric intraocular lens (IOL. Method: Case report and literature review. Results: Surgical technique and long-term follow-up for a patient who underwent repositioning and stabilization of a mobile 1-piece acrylic toric IOL using reverse optic capture (ROC are described. This patient presented with early, more than 70° off-axis rotation. The IOL was repositioned but was very mobile within the bag and tended to rotate off-axis; hence, it was stabilized in the desired position by capturing the optic through the anterior continuous curvilinear capsulorhexis, leaving the haptics in the bag. The immediate and 2-year postoperative follow-up revealed a stable and on-axis IOL with no visual, refractive or ocular complications. Conclusions: ROC is a useful and safe technique to address the problem of toric IOLs that tend to rotate at the time of surgery or are not stable postoperatively.

  9. Intraocular Implants for the Treatment of Autoimmune Uveitis

    Directory of Open Access Journals (Sweden)

    Darren J. Lee

    2015-07-01

    Full Text Available Uveitis is the third leading cause of blindness in developed countries. Currently, the most widely used treatment of non-infectious uveitis is corticosteroids. Posterior uveitis and macular edema can be treated with intraocular injection of corticosteroids, however, this is problematic in chronic cases because of the need for repeat injections. Another option is systemic immunosuppressive therapies that have their own undesirable side effects. These systemic therapies result in a widespread suppression of the entire immune system, leaving the patient susceptible to infection. Therefore, an effective localized treatment option is preferred. With the recent advances in bioengineering, biodegradable polymers that allow for a slow sustained-release of a medication. These advances have culminated in drug delivery implants that are food and drug administration (FDA approved for the treatment of non-infectious uveitis. In this review, we discuss the types of ocular implants available and some of the polymers used, implants used for the treatment of non-infectious uveitis, and bioengineered alternatives that are on the horizon.

  10. Soft wearable contact lens sensor for continuous intraocular pressure monitoring.

    Science.gov (United States)

    Chen, Guo-Zhen; Chan, Ion-Seng; Leung, Leo K K; Lam, David C C

    2014-09-01

    Intraocular pressure (IOP) is a primary indicator of glaucoma, but measurements from a single visit to the clinic miss the peak IOP that may occur at night during sleep. A soft chipless contact lens sensor that allows the IOP to be monitored throughout the day and at night is developed in this study. A resonance circuit composed of a thin film capacitor coupled with a sensing coil that can sense corneal curvature deformation is designed, fabricated and embedded into a soft contact lens. The resonance frequency of the sensor is designed to vary with the lens curvature as it changes with the IOP. The frequency responses and the ability of the sensor to track IOP cycles were tested using a silicone rubber model eye. The results showed that the sensor has excellent linearity with a frequency response of ∼8 kHz/mmHg, and the sensor can accurately track fluctuating IOP. These results showed that the chipless contact lens sensor can potentially be used to monitor IOP to improve diagnosis accuracy and treatment of glaucoma.

  11. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P.

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful. PMID:27462251

  12. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens.

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  13. Surgical management of astigmatism with toric intraocular lenses

    Directory of Open Access Journals (Sweden)

    Bruna V. Ventura

    2014-04-01

    Full Text Available Correction of corneal astigmatism is a key element of cataract surgery, since post-surgical residual astigmatism can compromise the patient's uncorrected visual acuity. Toric intraocular lenses (IOLs compensate for corneal astigmatism at the time of surgery, correcting ocular astigmatism. They are a predictable treatment. However, accurate measurement of corneal astigmatism is mandatory for choosing the correct toric IOL power and for planning optimal alignment. When calculating the power of toric IOLs, it is important to consider anterior and posterior corneal astigmatism, along with the surgically induced astigmatism. Accurate toric lens alignment along the calculated meridian is also crucial to achieve effective astigmatism correction. There are several techniques to guide IOL alignment, including the traditional manual marking technique and automated systems based on anatomic and topographic landmarks. The aim of this review is to provide an overview on astigmatism management with toric IOLs, including relevant patient selection criteria, corneal astigmatism measurement, toric IOL power calculation, toric IOL alignment, clinical outcomes and complications.

  14. Surface modification of intraocular lenses to reduce corneal endothelial damage.

    Science.gov (United States)

    Knight, P M; Link, W J

    1979-04-01

    Two methods of surface modification of PMMA, permanent and temporary, were investigated for use on intraocular lenses to reduce corneal endothelial damage due to corneal-IOL touch. Monomer grafting using gamma irradiation was found to produce permanently hydrophilic surfaces. Temporary surface modifications developed and tested were peelable and dissolvable coatings. Test samples were touched to freshly excised rabbit corneas to evaluate the effectiveness of the various surface modifications in reducing endothelial cell damage. This touch testing was performed using static testing in which the test sample was touched to the cornea without movement and dynamic testing in which there was relative movement between the cornea and the test sample. While unmodified PMMA did significant cell damage in both static and dynamic tests perpamently modified (hydrophilic grafted) surfaces were found to perform well in the static, but not in the dynamic tests. Dissolvable coatings performed well in both tests, even with very thin coatings. There was little differentiation between the various water-soluble coatings tested. Due to its characteristics and rate of dissolution, polyvinyl alcohol appears to be an optimum material for coating IOLs. A series of in vitro and in vivo tests performed to assess its safety indicate that PVA is nontoxic and safe in animal eyes. PMID:479004

  15. Measurement of Intraocular Pressure after LASIK by Dynamic Contour Tonometry

    Institute of Scientific and Technical Information of China (English)

    LIU Lei; LEI Cheng; LI Xinyu; Dong Jieyu

    2006-01-01

    Changes of corneal properties induced by laser in situ keratomileusis (LASIK) results in low inaccurate intraocular pressure (IOP) readings by Goldmann applanation tonometry (GAT).Before and after LASIK, the applied value of IOP, measured by dynamic contour tonometry (DCT)in comparison to GAT, was evaluated. Before and 1, 4 weeks after LASIK, the IOP in 30 cases (60 eyes) was measured by GAT and DCT respectively. The obtained results were statistically processed by SPSS11. 5 statistical software. The results showed that central corneal thickness (CCT)could affect GAT measurements but not DCT measurements. The comparison of IOP one and 4 weeks after LASIK revealed that the readings from GAT was separately decreased by 5.00±1.12 and 5.45±1. 13 mmHg as compared with those before LASIK, while those from DCT had no significant difference. It was concluded that LASIK-induced changes of CCT could influence the accuracy of GAT measurements, but had no influence on those from DCT. DCT was more beneficial to the measurements of IOP in normal eyes and those subject to LASIK surgery.

  16. Hypobaric Hypoxia: Effects on Intraocular Pressure and Corneal Thickness

    Directory of Open Access Journals (Sweden)

    Marcella Nebbioso

    2014-01-01

    Full Text Available Objective. The purpose of this study focused on understanding the mechanisms underlying ocular hydrodynamics and the changes which occur in the eyes of subjects exposed to hypobaric hypoxia (HH to permit the achievement of more detailed knowledge in glaucomatous disease. Methods. Twenty male subjects, aged 32±5 years, attending the Italian Air Force, were enrolled for this study. The research derived from hypobaric chamber, using helmet and mask supplied to jet pilotes connected to oxygen cylinder and equipped with a preset automatic mixer. Results. The baseline values of intraocular pressure (IOP, recorded at T1, showed a mean of 16±2.23 mmHg, while climbing up to 18,000 feet the mean value was 13.7±4.17 mmHg, recorded at T2. The last assessment was performed returning to sea level (T4 where the mean IOP value was 12.8±2.57 mmHg, with a significant change (P<0.05 compared to T1. Pachymetry values related to corneal thickness in conditions of hypobarism revealed a statistically significant increase (P<0.05. Conclusions. The data collected in this research seem to confirm the increasing outflow of aqueous humor (AH in the trabecular meshwork (TM under conditions of HH.

  17. Macroglobulinemia de Waldenström com hemorragia intra-ocular Waldenström's macroglobulinaemia with intraocular hemorrhage

    Directory of Open Access Journals (Sweden)

    João J. Nassaralla Júnior

    2006-12-01

    Full Text Available O objetivo deste trabalho é relatar um caso de macroglobulinemia de Waldenström com envolvimento retiniano e da circulação coroidiana, com boa resposta ao tratamento. O desenho é um caso controle intervencional. Um homem de 47 anos foi encaminhado para o serviço de hematologia para avaliação de anemia e linfadenopatia inguinal. O diagnóstico de macroglobulinemia de Waldenström foi feito com base nos achados clínicos e laboratoriais. O paciente desenvolveu hemorragia intra-ocular sem associação com hipertensão e com fatores de coagulação normais. Exame fundoscópico revelou retardamento na circulação coriorretiniana, microaneurismas, e telangiectasias no pólo posterior. Angiografia fluorescente demonstrou o prolongamento do tempo da circulação coroidiana, tempo de trânsito arteriovenoso também prolongado, e áreas de não perfusão capilar. Estes resultados foram acompanhados por uma elevação acentuada da IgM. A maioria dos achados oculares foi revertida com a plasmaférese. A macroglobulinemia de Waldenström pode envolver a retina e a circulação coroidiana, porém pode ser reversível com o tratamento apropriado.The aim of this work is to report a case of Waldenström's Macroglobulinaemia involving both retinal and choroidal circulation that resolved after treatment. The design is an interventional case report. A 47-year old male was admitted for evaluation of anaemia, and groin lymphadenopathy. A diagnosis of Waldenström's macroglobulinaemia was made based on clinical and laboratory findings. The patient developed intraocular hemorrhage without associated hypertension and with normal coagulation profile. A funduscopic examination revealed marked dilation and beading of the venous system, microaneurysms, and telangiectatic capillary beds in the posterior pole. A fluorescein angiography showed delayed choroidal filling, prolonged arteriovenous transit time and areas of capillary non-perfusion. These findings were

  18. Artificial insemination in poultry

    Science.gov (United States)

    Artificial insemination is a relative simple yet powerful tool geneticists can employ for the propagation of economically important traits in livestock and poultry. In this chapter, we address the fundamental methods of the artificial insemination of poultry, including semen collection, semen evalu...

  19. Onion artificial muscles

    Science.gov (United States)

    Chen, Chien-Chun; Shih, Wen-Pin; Chang, Pei-Zen; Lai, Hsi-Mei; Chang, Shing-Yun; Huang, Pin-Chun; Jeng, Huai-An

    2015-05-01

    Artificial muscles are soft actuators with the capability of either bending or contraction/elongation subjected to external stimulation. However, there are currently no artificial muscles that can accomplish these actions simultaneously. We found that the single layered, latticed microstructure of onion epidermal cells after acid treatment became elastic and could simultaneously stretch and bend when an electric field was applied. By modulating the magnitude of the voltage, the artificial muscle made of onion epidermal cells would deflect in opposing directions while either contracting or elongating. At voltages of 0-50 V, the artificial muscle elongated and had a maximum deflection of -30 μm; at voltages of 50-1000 V, the artificial muscle contracted and deflected 1.0 mm. The maximum force response is 20 μN at 1000 V.

  20. Electrochemical lysis at the stage of endoresection for large posterior intraocular tumors

    Directory of Open Access Journals (Sweden)

    Yu. A. Belyy

    2012-01-01

    Full Text Available Purpose: to design the new combined technique of endoresection with intraoperative intraocular electrochemical lysis at the tumor destruction stage for large posterior intraocular tumors.Methods: 3 patients (3 eyes with large choroidal melanomas t3N0M0 (tumor thickness — 8-10 mm, base diameter — 13-15 mm, juxtapapillary localization. Mean age was 55.4 years old. Endoresection with intraoperational intraocular electrochemical lysis of the tumor was performed. Electrochemical lysis was performed with use of the technical unit ECU 300 (Soering, Germany and the original method of combined intratumoral positioning of two platinum electrodes: anode and cathode.Results: the tumor was removal completely in all 3 cases. the anatomical retinal reattachment was reached in all patients. Sclera was safe in all 3 cases. Visual acuity was not changed (NLP. At the place of the removal tumor a surgical choroidal coloboma without pigmentation all over scleral bed and periphery was shown in all cases in distant postoperative period (from 1.5 to 3 years. No local recurrences or metastasis were revealed in all patients.Conclusion: Further investigations in clinical group are necessarily to determinate the real possibilities of the combined method and the indications for endoresection with intraoperative intraocular electrochemical lysis for large intraocular tumors. 

  1. Artificial intelligence in medicine.

    Science.gov (United States)

    Ramesh, A. N.; Kambhampati, C.; Monson, J. R. T.; Drew, P. J.

    2004-01-01

    INTRODUCTION: Artificial intelligence is a branch of computer science capable of analysing complex medical data. Their potential to exploit meaningful relationship with in a data set can be used in the diagnosis, treatment and predicting outcome in many clinical scenarios. METHODS: Medline and internet searches were carried out using the keywords 'artificial intelligence' and 'neural networks (computer)'. Further references were obtained by cross-referencing from key articles. An overview of different artificial intelligent techniques is presented in this paper along with the review of important clinical applications. RESULTS: The proficiency of artificial intelligent techniques has been explored in almost every field of medicine. Artificial neural network was the most commonly used analytical tool whilst other artificial intelligent techniques such as fuzzy expert systems, evolutionary computation and hybrid intelligent systems have all been used in different clinical settings. DISCUSSION: Artificial intelligence techniques have the potential to be applied in almost every field of medicine. There is need for further clinical trials which are appropriately designed before these emergent techniques find application in the real clinical setting. PMID:15333167

  2. Intraocular lens implantation for the treatment of astigmatism%人工晶状体植入术矫正散光

    Institute of Scientific and Technical Information of China (English)

    施俊廷; 徐雯

    2013-01-01

    Refractive intraocular lens surgery can be used for the treatment of moderate and high regular astigmatism.Refractive intraocular lens surgery includes aphakic intraocular lens surgery and phakic intraocular lens surgery.In phakic intraocular lens surgery two types of intraocular lenses are used:iris-claw intraocular lens and posterior chamber intraocular lens.The purpose of this article is to review current knowledge of surgical treatments of astigmatism with a particular focus on toric implantable collamer lenses.%人工晶状体(IOL)植入术能矫正中、高度规则散光.矫正散光的IOL植入术可分为无晶状体眼及有晶状体眼的环曲面IOL植入两类,其中有晶状体眼的环曲面IOL又可分为虹膜夹持型及后房型.本文旨在介绍IOL矫正散光的手术治疗方法,并着重介绍有晶状体眼植入后房型IOL矫正屈光不正合并散光的治疗技术.

  3. Intraocular lens power calculation in eyes with short axial length

    Directory of Open Access Journals (Sweden)

    Marilita M Moschos

    2014-01-01

    Full Text Available Aim: To evaluate and compare the predictive capacity of four intraocular lens (IOL power calculation formulas (SRK/T, Hoffer Q, Holladay 1, and Haigis in eyes shorter than 22.0 mm. Setting and Design: Observational study. Materials and Methods: Participants in our study were 69 consecutive patients with a preoperative axial length (AL of less than 22.0 mm in one or both eyes. All patients underwent phacoemulsification with IOL implantation and postoperative target of refraction was analyzed. Specifically, the differences in the mean absolute estimation error (AE for the four formulas were analyzed. Furthermore, the percentage of eyes with AE within ±0.5 and ±1.0 D for each formula was estimated, as well as the correlation coefficient (r between the AL and estimation error (E for each formula. The Mann-Whitney U test was used to compare differences in the AEs of the formulas. A statistically significant difference was defined as P < 0.05. Results: The Haigis formula had statistically significant smaller mean AE in comparison to Holladay 1, Hoffer Q, and SRK/T. The Haigis formula predicted more eyes with E within ±0.5 and ±1.0 D of predicted spherical equivalent compared to other formulas. Correlation between AL and AE revealed a negative r value and P < 0.05 for all formulas. Conclusions: Haigis formula provides more accurate results concerning the postoperative target of refraction in eyes with AL less than 22.0 mm. Hoffer Q could be also used as an alternative.

  4. Psychophysical Vision Simulation of Diffractive Bifocal and Trifocal Intraocular Lenses

    Science.gov (United States)

    Brezna, Wolfgang; Lux, Kirsten; Dragostinoff, Nikolaus; Krutzler, Christian; Plank, Nicole; Tobisch, Rainer; Boltz, Agnes; Garhöfer, Gerhard; Told, Reinhard; Witkowska, Katarzyna; Schmetterer, Leopold

    2016-01-01

    Purpose The visual performance of monofocal, bifocal, and trifocal intraocular lenses was evaluated by human individuals using a vision simulator device. This allowed investigation of the visual impression after cataract surgery, without the need actually to implant the lenses. Methods The randomized, double-masked, three-way cross-over study was conducted on 60 healthy male and female subjects aged between 18 and 35 years. Visual acuity (Early Treatment Diabetic Retinopathy Study; ETDRS) and contrast sensitivity tests (Pelli-Robson) under different lighting conditions (luminosities from 0.14–55 cd/m2, mesopic to photopic) were performed at different distances. Results Visual acuity tests showed no difference for corrected distance visual acuity data of bi- and trifocal lens prototypes (P = 0.851), but better results for the trifocal than for the bifocal lenses at distance corrected intermediate (P = 0.021) and distance corrected near visual acuity (P = 0.044). Contrast sensitivity showed no differences between bifocal and trifocal lenses at the distant (P = 0.984) and at the near position (P = 0.925), but better results for the trifocal lens at the intermediate position (P = 0.043). Visual acuity and contrast sensitivity showed a strong dependence on luminosity (P < 0.001). Conclusions At all investigated distances and all lighting conditions, the trifocal lens prototype often performed better, but never worse than the bifocal lens prototype. Translational Relevance The vision simulator can fill the gap between preclinical lens development and implantation studies by providing information of the perceived vision quality after cataract surgery without implantation. This can reduce implantation risks and promotes the development of new lens concepts due to the cost effective test procedure. PMID:27777828

  5. Computerized invasive measurement of time-dependent intraocular pressure

    Directory of Open Access Journals (Sweden)

    T.V.O. Campos

    2006-09-01

    Full Text Available Several methods have been described to measure intraocular pressure (IOP in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.

  6. Driving time modulates accommodative response and intraocular pressure.

    Science.gov (United States)

    Vera, Jesús; Diaz-Piedra, Carolina; Jiménez, Raimundo; Morales, José M; Catena, Andrés; Cardenas, David; Di Stasi, Leandro L

    2016-10-01

    Driving is a task mainly reliant on the visual system. Most of the time, while driving, our eyes are constantly focusing and refocusing between the road and the dashboard or near and far traffic. Thus, prolonged driving time should produce visual fatigue. Here, for the first time, we investigated the effects of driving time, a common inducer of driver fatigue, on two ocular parameters: the accommodative response (AR) and the intraocular pressure (IOP). A pre/post-test design has been used to assess the impact of driving time on both indices. Twelve participants (out of 17 recruited) completed the study (5 women, 24.42±2.84years old). The participants were healthy and active drivers with no visual impairment or pathology. They drove for 2h in a virtual driving environment. We assessed AR and IOP before and after the driving session, and also collected subjective measures of arousal and fatigue. We found that IOP and AR decreased (i.e., the accommodative lag increased) after the driving session (p=0.03 and p<0.001, respectively). Moreover, the nearest distances tested (20cm, 25cm, and 33cm) induced the highest decreases in AR (corrected p-values<0.05). Consistent with these findings, the subjective levels of arousal decreased and levels of fatigue increased after the driving session (all p-values<0.001). These results represent an innovative step towards an objective, valid, and reliable assessment of fatigue-impaired driving based on visual fatigue signs. PMID:27235337

  7. Early clinical outcome with a new monofocal microincision intraocular lens.

    Science.gov (United States)

    Toygar, Baha; Yabas Kiziloglu, Ozge; Toygar, Okan; Hacimustafaoglu, Ali Murat

    2016-10-01

    The purpose of this study was to evaluate the early visual and refractive outcomes of a new aspheric monofocal microincision intraocular lens (IOL). This retrospective case series included eyes of patients who underwent implantation of a microincision IOL following 1.8 mm manual coaxial microincision cataract surgery and who attended regular postoperative follow-up visits on the first week and first, third, and sixth months. The postoperative uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), refraction and predictability, intraoperative and postoperative complications, posterior capsule opacification (PCO), IOL centration, and surgically induced astigmatism (SIA) were evaluated. Sixty-three eyes of 38 patients ranging in age from 51 to 86 were included in the study. The mean preoperative BCVA was 0.52 ± 0.42 logMAR. At the postoperative sixth month, the mean postoperative UCVA and BCVA were 0.12 ± 0.11 and 0.01 ± 0.03 logMAR, respectively. The mean postoperative spherical equivalent refraction (SER) was -0.30 ± 0.49 D. The SER was within ± 1.00 D of the attempted correction in 95.2 % of the eyes. The mean SIA measured with vector analysis was 0.45 ± 0.28 D. Mild PCO was observed in 9 eyes (14.7 %) with none requiring Nd:Yag laser capsulotomy. On centration analysis, the IOL was found to be 0.26 mm on average to the supero-nasal position. The aspheric microincision IOL was safely implanted and provided satisfactory visual and refractive outcomes in the early postoperative period.

  8. Retreatments after multifocal intraocular lens implantation: an analysis

    Science.gov (United States)

    Gundersen, Kjell Gunnar; Makari, Sarah; Ostenstad, Steffen; Potvin, Rick

    2016-01-01

    Purpose To determine the incidence and etiology of required retreatment after multifocal intraocular lens (IOL) implantation and to evaluate the methods and clinical outcomes of retreatment. Patients and methods A retrospective chart review of 416 eyes of 209 patients from one site that underwent uncomplicated cataract surgery with multifocal IOL implantation. Biometry, the IOL, and refractive data were recorded after the original implantation, with the same data recorded after retreatment. Comments related to vision were obtained both before and after retreatment for retreated patients. Results The multifocal retreatment rate was 10.8% (45/416 eyes). The eyes that required retreatment had significantly higher residual refractive astigmatism compared with those who did not require retreatment (1.21±0.51 D vs 0.51±0.39 D, P<0.01). The retreatment rate for the two most commonly implanted primary IOLs, blended bifocal (10.5%, 16/152) and bilateral trifocal (6.9%, 14/202) IOLs, was not statistically significantly different (P=0.12). In those requiring retreatment, refractive-related complaints were most common. Retreatment with refractive corneal surgery, in 11% of the eyes, and piggyback IOLs, in 89% of the eyes, was similarly successful, improving patient complaints 78% of the time. Conclusion Complaints related to ametropia were the main reasons for retreatment. Residual astigmatism appears to be an important determinant of retreatment rate after multifocal IOL implantation. Retreatment can improve symptoms for a high percentage of patients; a piggyback IOL is a viable retreatment option. PMID:27041983

  9. Intraocular lens exchange for high myopia in pseudophakic children.

    Science.gov (United States)

    Kraus, C L; Trivedi, R H; Wilson, M E

    2016-09-01

    PurposeThe purpose of this study was to examine the preoperative factors and postoperative outcomes following intraocular lens (IOL) exchange for high myopia in pseudophakic children.MethodsThe medical records of all patients undergoing IOL exchange for high myopia were retrospectively reviewed.ResultsA total of 15 eyes were identified that had undergone an IOL exchange for myopic shift. Average age of cataract extraction (CE) was 5.4 months. In all, 10/15 had a unilateral cataract. IOL exchange usually occurred at an average of 6 years following cataract surgery. The average spherical equivalent (SE) of the refractive error at that time was -9.6 D. Following IOL exchange, SE was -1.3 D. A two-line reduction in best-corrected visual acuity was observed in 1/13 of our patients for whom pre- and post-exchange data were available. The average axial length (AL) of the eye undergoing the IOL exchange was 24.0 mm, average AL in the non-operative eye was 22.1 mm. On average, the operative eyes grew 4.4 mm and the non-operative eyes 3.02 mm. No adverse events were seen in the operative eyes.ConclusionYounger age at the time of CE creates a greater likelihood of AL elongation and predisposes a child to myopic shift. IOL exchange should be considered an option to reduce anisometropia and associated aniseikonia to improve visual outcomes. Successful visual rehabilitation and predictable post-exchange refractions were seen with our patients.

  10. Design of hillside elevator

    OpenAIRE

    Jaroš, Tomáš

    2014-01-01

    This Bachelor´s Thesis presents a structural proposal of a hillside elevator to a house on the slope used to carry goods and people. The elevator is designed in a total length of 40 meters with a capacity of 400 kilograms and slope of 25 degrees. The main focus aims at the drive of the machine and its safety. The elevator fulfills prescribed safety terms according to the 127/2004 directive. A 3D model of the elevator, a design drawing and drawings of its individual components are included.

  11. De stille elever

    DEFF Research Database (Denmark)

    Winther-Lindqvist, Ditte Alexandra

    2012-01-01

    Det er blevet en afgørende samværskompetence i uddannelsessystemet at stå aktivt frem og deltage verbalt i skoleklassens liv både fagligt og socialt. Men ikke alle elever deltager lige villigt verbalt i plenum. Artiklen handler om de stille elever og konsekvenserne af stillehed i skolen. Det...... foreslås at skolesystemet sanktionerer ældre elever hårdere for stillehed end yngre elever og det forklares med at skolelivet også er en kultivering henimod elevhed som social identitet og denne er der forventning om at eleverne mestrer i udskolingen....

  12. Modified Scleral Flap Incision to Reduce Corneal Astigmatisn after Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    YizhiLiu; ShaozhenLi

    1995-01-01

    Purpose:To investigate a simple method during extracapsular cataract extraction with posteior chamber intraocular lens implantation in order to reduce surgically induced corneal astig-matism.Methods:A modified scleral flap incision was used in the extracapsular cataract extraction with intraocular lens implantation and the postoperative changes in conreal astigmatism was observed.Results:The peak value of postoperative corneal astigmatism was3.60D,and the corneal astigmatism regression was 2.11D,surgically induced astigmatism was less significant in modified scleral flap incision group than that in convention-al limbal incison group(P<0.05).Conclusions:The modified scleral flap inciston is an ideal incision for cataract ex-traction with intraocular lens implantation when phacoemulsifier is not avaliable.Eye Science1995;11:136-139.

  13. Laser-triggered intraocular implant to induce photodynamic therapy for posterior capsule opacification prevention.

    Science.gov (United States)

    Zhang, Zhaoguo; Huang, Wenyong; Lei, Ming; He, Yuanfeng; Yan, Mina; Zhang, Xuefei; Zhao, Chunshun

    2016-02-10

    Posterior capsule opacification (PCO) is one of the main reasons for loss of vision again after cataract surgery. In this study, intraocular lenses were modified with indocyanine green (ICG) and sealed up with PLGA to form long-term intraocular implants (ICG-IOL). When triggered by laser, ICG-IOL would induce photodynamic therapy (PDT). In-vitro cell viability assay and scratch wound healing assay demonstrated that ICG-IOL could effectively inhibit HLEpiC proliferation and migration without causing damage to the cells far away from it. Laser attenuation test indicated that ICG-IOL could be applied in vivo. In-vivo pharmacodynamics and safety study showed that ICG-IOL could significantly prevent the occurrence of PCO and was safe for intraocular normal tissue. All these results suggested that ICG-IOL would be a very promising candidate for PCO prevention.

  14. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses

    Directory of Open Access Journals (Sweden)

    Wei Ching-Kuo

    2012-10-01

    Full Text Available Abstract Background The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients’ decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. Methods This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one’s own expense, overall patient satisfaction and postoperative visual clarity. Results The results showed that the patient’s gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Conclusions Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.

  15. Role of interferon-γ and cytotoxic T lymphocytes in intraocular tumor rejection.

    Science.gov (United States)

    Ligocki, Ann J; Brown, Joseph R; Niederkorn, Jerry Y

    2016-05-01

    The eye is normally an immunosuppressive environment. This condition is better known as immune privilege and protects the eye from immune-mediated inflammation of tissues that cannot regenerate. However, immune privilege creates a dilemma for the eye when intraocular neoplasms arise. In some cases, immune privilege is suspended, resulting in the immune rejection of intraocular tumors. This study employed a mouse model in which interferon-γ-dependent intraocular tumor rejection occurs. We tested the hypothesis that this rejection requires interferon-γ for the generation and functional capacity of cytotoxic T lymphocyte-mediated rejection of intraocular tumors. Tumors grew progressively in the eyes of interferon-γ knockout mice, even though the mice generated tumor-specific cytotoxic T lymphocyte responses in the periphery. However, interferon-γ knockout mice rejected tumors that were introduced into extraocular sites. Subcutaneous tumor immunization before intraocular challenge led to tumor rejection and preservation of the eye in wild-type mice. By contrast, tumors grew progressively in the eyes of interferon-γ knockout mice despite their ability to generate peripheral tumor-specific cytotoxic T lymphocytes as well as the capacity of CD8(+) T cells to enter the eye as shown by the presence of CD8 and perforin message and CD3(+)CD8(+) leukocytes within the tumor-bearing eye. We found that cytotoxic T lymphocytes generated in wild-type mice and adoptively transferred into interferon-γ knockout mice mediated the rejection of intraocular tumors in interferon-γ knockout hosts. The results indicate that interferon-γ is critical for the initial priming and differentiation of cytotoxic T lymphocytes residing in the periphery to produce the most effect antitumor function within the eye.

  16. Immediate retinal adhesion by CO2 laser irradiation using a fiberoptic intraocular probe.

    Science.gov (United States)

    DeRowe, A; Bartov, E; Treister, G; Belkin, M; Katzir, A

    1992-01-01

    Using an experimental fiberoptically guided CO2 laser system, we produced lesions on fresh bovine retinas. These lesions were shown to achieve immediate measurable chorioretinal adhesion. This model provides preliminary data on the use of a fiberoptic CO2 laser probe to produce chorioretinal lesions and possible future use in intraocular surgery for retinal detachment. The advantages of using CO2 laser energy are minimal damage surrounding desired lesion and its versatility as a coagulator and cutter. With modifications, CO2 endolaser may have a role in intraocular surgery. PMID:1453861

  17. Ophthalmic viscosurgical device backflow into cartridge during intraocular lens insertion using injectors

    Directory of Open Access Journals (Sweden)

    Matsuura K

    2014-01-01

    Full Text Available Kazuki Matsuura,1 Yoshitsugu Inoue2 1Nojima Hospital, 2Tottori University, Kurayoshi City, Tottori, Japan Background: The purpose of this study was to assess the risk of intraocular contamination caused by intraocular lens (IOL insertion with injectors by observing the dynamics of an ophthalmic viscosurgical device (OVD. Methods: Each type of injector was equipped with a colored OVD and IOL, and a 2 mm length from the tip of the cartridge was replaced with a colored OVD. The various combinations of IOLs and injectors used were: a three-piece shaped IOL, VA60BBR + TypeE1 (HOYA incision size 2.5 mm; group A, n=5; a single-piece IOL, 251+ iSert micro, preloaded (HOYA, incision size 2.2 mm; group G, n=5; and a single-piece IOL, SN6CWS preloaded (Alcon, incision size 2.7 mm; group C, n=5. Results: In group A, the intraocular OVD instantly flowed backward into the injector, whereas the colored OVD was pushed backward deep inside the cartridge without flowing into the eye. In group B, the backflow of the intraocular OVD into the injector was limited, resulting in the influx of a large amount of the colored OVD into the eye along with the IOL. In group C, as in group A, a large amount of the intraocular OVD flowed backward into the injector. Consequently, a small amount of the colored OVD flowed into the eye. Conclusion: The tip of the injector and OVD could be contaminated because the surgical field cannot be completely sterile, even after preoperative disinfection. Our experiments revealed that OVD backflow into the injector cavity occurs during IOL insertion, and this phenomenon may have minimized intraocular contamination. However, small-diameter cartridges along with plate-type haptics allow insufficient OVD backflow, resulting in intraocular influx of the contaminated OVD. Surgeons have to be notified that intraoperative bacterial contamination can occur even after IOL insertion using injectors. Keywords: intraocular lens insertion

  18. Intraocular/Intracranial pressure mismatch hypothesis for visual impairment syndrome in space.

    Science.gov (United States)

    Zhang, Li-Fan; Hargens, Alan R

    2014-01-01

    Visual impairment intracranial pressure syndrome (VIIP) is considered a major risk for future human spaceflight. Loss of hydrostatic pressure gradients in vascular and cerebrospinal fluid systems due to the removal of gravity associated with subsequent intracranial and intraocular fluid shifts and the resulting intraocular/intracranial pressure mismatch might be important etiology factors causingVIIP syndrome. Acclimation changes in the ocular and cerebral circulation and the two fluid systems during chronic microgravity exposure and their underlying mechanisms need further elucidation. Relevant findings may help to validate the pressure differential hypothesis for VlIP syndrome and to evaluate whether a gravity based countermeasure is needed. PMID:24479265

  19. Symbolic algebra approach to the calculation of intraocular lens power following cataract surgery

    Science.gov (United States)

    Hjelmstad, David P.; Sayegh, Samir I.

    2013-03-01

    We present a symbolic approach based on matrix methods that allows for the analysis and computation of intraocular lens power following cataract surgery. We extend the basic matrix approach corresponding to paraxial optics to include astigmatism and other aberrations. The symbolic approach allows for a refined analysis of the potential sources of errors ("refractive surprises"). We demonstrate the computation of lens powers including toric lenses that correct for both defocus (myopia, hyperopia) and astigmatism. A specific implementation in Mathematica allows an elegant and powerful method for the design and analysis of these intraocular lenses.

  20. Sensitivity of the corneal-plane refractive compensation to change in power and axial position of an intraocular lens

    Directory of Open Access Journals (Sweden)

    W. F. Harris

    2009-12-01

    Full Text Available If an intraocular lens is displaced or if its power is changed what are the consequences for the refractive compensation of the eye?  Gaussian optics is used to obtain explicit formulae for the sensitivityof the corneal-plane refractive compensation (also called the refraction, refractive state, etc to change in power and axial displacement of a thin intraocular lens implanted in a simple eye.  In particular, for a pseudophakic Gullstrand simplified eye with intraocular lens placed 5 mm behind the cornea the sensitivity to errors in the power of the intraocular lens is about  71 . 0 − 71 for an intraocular lens of power   for an intraocular lens of power 20 D, that is, the refractive compensation decreases by about 0.71 dioptres per dioptre increase in the power of the intraocular lens.  More generally the sensitivity is approximately  ( m   0037 . 0 63 . 0 F − − 0.63 ( 003 . 0 63 . 0 − − (0.0037mF where FI is the power of the intraocular lens.  Also for Gullstrand’s simplified eye the sensitivity of refractive compensation to axial displacement of the intraocular lens is approximately linear in FI about  (64D FI, in fact.  That is, for each dioptre of the power of the intraocular lens the refractive compensation increases by about 0.064 dioptres per millimetre of axial displacement towards the retina. 

  1. Principles of artificial intelligence

    CERN Document Server

    Nilsson, Nils J

    1980-01-01

    A classic introduction to artificial intelligence intended to bridge the gap between theory and practice, Principles of Artificial Intelligence describes fundamental AI ideas that underlie applications such as natural language processing, automatic programming, robotics, machine vision, automatic theorem proving, and intelligent data retrieval. Rather than focusing on the subject matter of the applications, the book is organized around general computational concepts involving the kinds of data structures used, the types of operations performed on the data structures, and the properties of th

  2. The Artificial Anal Sphincter

    OpenAIRE

    Christiansen, John

    2000-01-01

    The artificial anal sphincter as treatment for end stage anal incontinence was first described in 1987. Published series concern a total of 42 patients, with a success rate of approximately 80%. Infection has been the most serious complication, but a number of technical complications related to the device have also occurred and required revisional procedures in 40% to 60% of the patients. The artificial anal sphincter may be used for the same indications as dynamic graciloplasty except in pat...

  3. Comparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens

    Science.gov (United States)

    Gundersen, Kjell Gunnar; Potvin, Rick

    2016-01-01

    Purpose The aim of this study was to compare a new diffractive trifocal toric lens with an apodized diffractive bifocal toric lens in terms of refractive and visual acuity (VA) outcomes, including low-contrast VA (LCVA), as well as the patient’s visual function 3 months after implantation. Patients and methods This is a randomized prospective study involving bilateral implantation of a trifocal toric or a bifocal toric lens. At 3 months postoperatively, the subject’s vision was tested both uncorrected and with his/her best distance correction at: distance (4 m), intermediate (63 cm), and near (40 cm). Binocular defocus curves were measured with no correction and with the subject’s best distance correction in place. Quality of vision was measured using the National Eye Institute Visual Function Questionnaire. Results A total of 22 patients were enrolled (eleven in each group). There was no statistically significant difference in the absolute change in measured rotation between 1 month and 3 months postoperatively between the two intraocular lens (IOL) groups (P=0.98). At 3 months, the postoperative refraction and distance VA by eye were similar between groups. There was no statistically significant difference in the measured LCVA between groups (P=0.39). The defocus curve showed that at 67 cm, the trifocal toric lens had statistically significantly better VA when compared to the bifocal toric lens. There were no statistically significant differences by group for any of the National Eye Institute Visual Function Questionnaire scores (P>0.26 in all cases). Conclusion The trifocal toric IOL improved the intermediate vision without negatively impacting visual function and distance, near, or low-contrast VA when compared to a bifocal toric IOL. The toric component of the trifocal lens effectively reduced astigmatism and provided good rotational stability. PMID:27051269

  4. Undervisning af tosprogede elever

    DEFF Research Database (Denmark)

    Horst, Christian

    2003-01-01

    Artiklen fremdrager hovedresultaterne fra Virginia P. Collier's og Wayne P. Thomas's længdeundersøgelser af tosprogede elever i USA, som formentlig er de mest omfattende undersøgelser af undervisningen af tosprogede elever overhovedet. Resultaterne diskuteres i relation til udviklingen af en...

  5. Time Course of Age-dependent Changes in Intraocular Pressure and Retinal Ganglion Cell Death in DBA/2J Mouse

    Institute of Scientific and Technical Information of China (English)

    Xiulan Zhang; Mei Zhang; Marcel Y. Avila; Jian Ge; Alan M. Laties

    2006-01-01

    Purpose: To characterizes the progression of glaucoma in DBA/2J mice by measuring intraocular pressure (IOP) and retinal ganglion cells (RGCs) numbers in mice of various ages.Methods: A quantitative assessment of the pathophysiology of the DBA/2J mice was performed and the C57/BL6 mice was used as control. The IOP was measured by the servo-null micropipette system; the regional patterns of the loss of RGCs were determined by cell count of retrogradely-labeled RGCs.Results: The baseline IOP for DBA/2J mice at 7 weeks was (16.6 ± 1.2)mm Hg.Then IOP increased extend to 12 months, with the peak of (25.2 ± 1.2)mm Hg at 6 months of age. Retinal ganglion cell numbers did not decrease relative to control until 12 months of age (P=0.006), when the loss was proportionally higher in peripheral regions (P<0.05).Conclusion: The elevation in IOP precedes the loss of RGCs by several months.RGCs cell loss occurs particularly in peripheral regions of the retina. These findings expand our understanding of the changes in DBA/2J mice and provide information for experiments design when they are used as a glaucoma model for future studies of RGCs degeneration in glaucoma.

  6. Interface Fluid Syndrome Induced by Uncontrolled Intraocular Pressure Without Triggering Factors After LASIK in a Glaucoma Patient: A Case Report.

    Science.gov (United States)

    Shoji, Nobuyuki; Ishida, Akira; Haruki, Takahiro; Matsumura, Kazuhiro; Kasahara, Masayuki; Shimizu, Kimiya

    2015-09-01

    This study sought to describe a glaucoma patient with interface fluid syndrome (IFS) induced by uncontrolled intraocular pressure (IOP) without triggering factors after laser in situ keratomileusis (LASIK). Case report and review of the literature. A 23-year-old man with open-angle glaucoma underwent bilateral LASIK for myopia in 2009. Two years later, the patient reported sudden vision loss. The IOP in the right eye was not measurable using Goldmann applanation tonometry (GAT), but was determined to be 33.7 mm Hg using a noncontact tonometer. IFS was diagnosed based on the presence of space-occupying interface fluid on anterior segment optical coherence tomography images. After a trabeculectomy was performed, the IOP decreased to 10 mm Hg, and GAT measurement became possible. However, the corneal fold remained visible in the flap interface. Six months later, the IOP in the left eye increased, and a trabeculectomy was performed during the early stages of this increase in IOP. Following this procedure, the IOP decreased, and visual acuity remained stable. In glaucoma cases that involve a prior increase in IOP, IOP can continue to increase during the disease course even if temporary control of IOP has been achieved. If LASIK is performed in such cases, the treatment of glaucoma becomes insufficient because of underestimation of the typical IOP. In fact, the measurement of IOP can become difficult because of high-IOP levels. Therefore, LASIK should not be performed on patients with glaucoma who are at high risk of elevated IOP. PMID:26426645

  7. Intraocular and systemic levels of vascular endothelial growth factor in advanced cases of retinopathy of prematurity

    Directory of Open Access Journals (Sweden)

    Raul Velez-Montoya

    2010-08-01

    Full Text Available Raul Velez-Montoya1, Carmen Clapp2, Jose Carlos Rivera2, Gerardo Garcia-Aguirre1, Virgilio Morales-Cantón1, Jans Fromow-Guerra1, Jose Luis Guerrero-Naranjo1, Hugo Quiroz-Mercado31Retina Department Asociación para Evitar la Ceguera en México IAP, México City, México; 2Department of Cellular and Molecular Neurobiology, Universidad Nacional Autónoma de México, Querétaro, México; 3Department of Ophthalmology, Denver Health Medical Center, University of Colorado School of Medicine, Colorado, USAPurpose: To measure vitreous, aqueous, subretinal fluid and plasma levels of vascular ­endothelial growth factor in late stages of retinopathy of prematurity.Methods: Interventional study. We enrolled patients with clinical diagnoses of bilateral stage V retinopathy of prematurity, confirmed by b-scan ultrasound and programmed for vitrectomy. During surgery we took samples from blood, aqueous, vitreous, and subretinal fluids. The vascular endothelial growth factor concentration in each sample was measured by ELISA reaction. A control sample of aqueous, vitreous and blood was taken from patients with congenital cataract programmed for phacoemulsification. For statistical analysis, a Mann–Whitney and a Wilcoxon W test was done with a significant P value of 0.05.Results: We took samples of 16 consecutive patients who met the inclusion criteria. The vascular endothelial growth factor levels in the study group were: aqueous, 76.81 ± 61.89 pg/mL; vitreous, 118.53 ± 65.87 pg/mL; subretinal fluid, 1636.58 ± 356.47 pg/mL; and plasma, 74.64 ± 43.94 pg/mL. There was a statistical difference between the study and the control group (P < 0.001 in the aqueous and vitreous samples.Conclusion: Stage 5 retinopathy of prematurity has elevated intraocular levels of vascular endothelial growth factor, which remains high despite severe retinal lesion. There was no ­statistical difference in plasma levels of the molecule between the control and study group

  8. Visual quality of multifocal, accommodative and monofocal intraocular lens: a comparative study of 139 eyes%多焦点、可调节和单焦点人工晶状体临床视觉质量的观察

    Institute of Scientific and Technical Information of China (English)

    郑登易; 叶剑; 谭薇

    2012-01-01

    concurrent control trial was carried out in 95 patients (139 eyes) with age-related cataract who receiving phacoemulsification and implantation of artificial intraocular lens in our department during September 2010 to April 2011. Forty-three eyes of 30 patients underwent phacoemulsification and implantation of ZMA00, and another 33 age- and sex-matched patients (49 eyes) and 32 patients (47 eyes) had the same surgery but implantated with FLEX and AKROS respectively. All patients were assessed for visual acuity, accommodation amplitude and contrast sensitivity visual acuity in 1 d, 1 and 3 months after operation. Results During the follow-up time, the patients in the ZMAOO and FLEX groups had better vision acuity than the AKROS group in uncorrected distance vision acuity ( UDVA) , but no significant difference was found (P > 0. 05). And the patients in the ZMA00 and FLEX groups had better corrected intermediate vision acuity (CIVA) than the AKROS group (P 0. 05). There were 86. 7% patients of the ZMA00 group, 63.6% of the FLEX group, and 18. 8% of the AKROS group achieving total spectacle independence. Conclusion Three kinds of artificial lens can get better distance vision, but multifocal and accommodative intraocular lens possesses far better, and the higher rate of spectacle independence. Aspheric multifocal intraocular lens have no loss in contrast sensitivity, and take greater advantages than accommodating intraocular lensin near vision, and pseudo-conditioning capability.

  9. Drug loading of foldable commercial intraocular lenses using supercritical impregnation.

    Science.gov (United States)

    Bouledjouidja, A; Masmoudi, Y; Sergent, M; Trivedi, V; Meniai, A; Badens, E

    2016-03-16

    The drug delivery through intraocular lenses (IOLs) allows the combination of cataract surgery act and postoperative treatment in a single procedure. In order to prepare such systems, "clean" supercritical CO2 processes are studied for loading commercial IOLs with ophthalmic drugs. Ciprofloxacin (CIP, an antibiotic) and dexamethasone 21-phosphate disodium (DXP, an anti-inflammatory drug) were impregnated into foldable IOLs made from poly-2-hydroxyethyl methacrylate (P-HEMA). A first pre-treatment step was conducted in order to remove absorbed conditioning physiological solution. Supercritical impregnations were then performed by varying the experimental conditions. In order to obtain transparent IOLs and avoid the appearance of undesirable foaming, it was necessary to couple slow pressurization and depressurization phases during supercritical treatments. The impregnation yields were determined through drug release studies. For both drugs, release studies show deep and reproducible impregnation for different diopters. For the system P-HEMA/CIP, a series of impregnations was performed to delimit the experimental range at two pressures (80 and 200 bar) in the presence or absence of ethanol as a co-solvent for two diopters (+5.0 D and +21.0 D). Increase in pressure in the absence of a co-solvent resulted in improved CIP impregnation. The addition of ethanol (5 mol%) produced impregnation yields comparable to those obtained at 200 bar without co-solvent. A response surface methodology based on experimental designs was used to study the influence of operating conditions on impregnation of IOLs (+21.0 D) in the absence of co-solvent. Two input variables with 5 levels each were considered; the pressure (80-200 bar) and the impregnation duration (30-240 min). CIP impregnation yields ranging between 0.92 and 3.83 μg CIP/mg IOL were obtained from these experiments and response surface indicated the pressure as a key factor in the process. The DXP impregnation in P-HEMA was

  10. Intraocular infections in the neonatal intensive care unit

    Directory of Open Access Journals (Sweden)

    Sisk RA

    2012-05-01

    Full Text Available Hassan A Aziz1, Audina M Berrocal1,2, Robert A Sisk1, Kristin Hartley1, Magaly Diaz-Barbosa2, Rose A Johnson2, Ditte Hess1, Sander R Dubovy1, Timothy G Murray1, Harry W Flynn Jr11Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, 2Jackson Memorial Hospital, Miami, FL, USABackground: The purpose of this study was to report on the incidence and treatment outcomes of endogenous endophthalmitis among newborns in the neonatal intensive care unit (NICU of a single medical center.Methods: This was a noncomparative, retrospective case series of endogenous endophthalmitis among infants at the Jackson Memorial Hospital NICU treated between March 1, 2002 and March 1, 2007.Results: Of 4323 infants admitted to the NICU, seven eyes of six (0.139% infants (two males, four females were diagnosed with endophthalmitis during the study period. Four patients were born prematurely with a mean gestational age of 27.5 weeks and a mean birth weight of 1153 g. Retinopathy of prematurity was reported in two of the six patients. Mean follow-up was 3.5 years. The diagnosis was confirmed by positive cultures or polymerase chain reaction testing at a median age of 34 postnatal days. Positive cultures included Candida albicans (n = 4, Pseudomonas aeruginosa (n = 1, and Herpes simplex type 2 (n = 1. All patients received systemic treatment and five received adjunctive ophthalmic interventions, including intravitreal antibiotics in five eyes of four patients and vitrectomy with pars plana lensectomy in three eyes. One patient underwent primary enucleation and another had delayed evisceration. In the remaining five eyes, there was a normal appearing posterior segment and normal intraocular pressures at last follow-up.Conclusion: Endogenous endophthalmitis is a rare complication in infants in the NICU, but may occur in patients with candidemia, bacteremia, retinopathy of prematurity, and low birth weight. Despite early and

  11. Toric intraocular lens orientation and residual refractive astigmatism: an analysis

    Directory of Open Access Journals (Sweden)

    Potvin R

    2016-09-01

    Full Text Available Rick Potvin,1 Brent A Kramer,2 David R Hardten,3 John P Berdahl4 1Science in Vision, Akron, NY, 2University of Iowa Carver College of Medicine, Iowa City, IA, 3Minnesota Eye Consultants, Minnetonka, MN, 4Vance Thompson Vision, Sioux Falls, SD, USA Purpose: To analyze intraocular lens (IOL orientation data from an online toric back-calculator (astigmatismfix.com for determining if differences were apparent by lens type.Methods: A retrospective review of astigmatismfix.com toric back-calculations that included IOL identification and intended orientation axis.Results: Of 12,812 total validated calculation records, 8,229 included intended orientation and lens identification data. Of the latter, 5,674 calculations (69% involved lenses oriented 5° or more from their intended position. Using estimated toric lens usage data, the percentage of lenses with orientation ≥5° from intended was 0.89% overall, but the percentage varied significantly between specific toric lens brands (P<0.05. The percentage of back-calculations related to lenses that were not oriented as intended was also statistically significantly different by lens brand (P<0.05. When IOLs were misoriented, they were significantly more likely to be misoriented in a counterclockwise direction (P<0.05. This was found to be due to a bias toward counterclockwise orientation observed with one specific brand, a bias that was not observed with the other three brands analyzed here.Conclusion: The percentage of eyes with lens orientation ≥5° from intended in the Toric Results Analyzer data set was <1% of toric IOLs in general, with the relative percentage of Tecnis® Toric IOLs significantly higher than AcrySof® Toric IOLs. Both of these had higher rates than the Staar® Toric and Trulign® Toric lenses, with the availability of higher Tecnis and AcrySof cylinder powers a likely contributing factor. The AcrySof Toric IOL appears to be less likely than the Tecnis Toric IOL to cause residual

  12. Comparison of two optical biometers in intraocular lens power calculation

    Directory of Open Access Journals (Sweden)

    Sheng Hui

    2014-01-01

    Full Text Available Aims: To compare the consistency and accuracy in ocular biometric measurements and intraocular lens (IOL power calculations using the new optical low-coherence reflectometry and partial coherence interferometry. Subjects and Methods: The clinical data of 122 eyes of 72 cataract patients were analyzed retrospectively. All patients were measured with a new optical low-coherence reflectometry system, using the LENSTAR LS 900 (Haag Streit AG/ALLEGRO BioGraph biometer (Wavelight., AG, and partial coherence interferometry (IOLMaster V.5.4 [Carl Zeiss., Meditec, AG] before phacoemulsification and IOL implantation. Repeated measurements, as recommended by the manufacturers, were performed by the same examiner with both devices. Using the parameters of axial length (AL, corneal refractive power (K1 and K2, and anterior chamber depth (ACD, power calculations for AcrySof SA60AT IOL were compared between the two devices using five formulas. The target was emmetropia. Statistical analysis was performed using Statistical Package for the Social Sciences software (SPSS 13.0 with t-test as well as linear regression. A P value < 0.05 was considered to be statistically significant. Results: The mean age of 72 cataract patients was 64.6 years ± 13.4 [standard deviation]. Of the biometry parameters, K1, K2 and [K1 + K2]/2 values were significantly different between the two devices (mean difference, K1: −0.05 ± 0.21 D; K2: −0.12 ± 0.20 D; [K1 + K2]/2: −0.08 ± 0.14 D. P <0.05. There was no statistically significant difference in AL and ACD between the two devices. The correlations of AL, K1, K2, and ACD between the two devices were high. The mean differences in IOL power calculations using the five formulas were not statistically significant between the two devices. Conclusions: New optical low-coherence reflectometry provides measurements that correlate well to those of partial coherence interferometry, thus it is a precise device that can be used for the

  13. Investigations of the ionospheric using radio signals from artificial satellites

    Science.gov (United States)

    Titheridge, J. E.

    1973-01-01

    The occurrence and characteristics of ionospheric irregularities in medium latitudes and in polar regions were measured using radio signals from artificial satellites. Ionospheric changes during quiet and disturbed conditions were also measured. Electron density, elevation angle, and amplitude and frequency of these high frequency signals were determined as well as the direction of their arrival.

  14. Comparative evaluation of intraocular pressure changes subsequent to insertion of laryngeal mask airway and endotracheal tube.

    Directory of Open Access Journals (Sweden)

    Ghai B

    2001-07-01

    Full Text Available AIMS: To evaluate the intraocular pressure and haemodynamic changes subsequent to insertion of laryngeal mask airway and endotracheal tube. SUBJECTS AND METHODS: The study was conducted in 50 adult patients. A standard general anaesthesia was administered to all the patients. After 3 minutes of induction of anaesthesia baseline measurements of heart rate, non-invasive blood pressure and intraocular pressure were taken following which patients were divided into two groups: laryngeal mask airway was inserted in group 1 and tracheal tube in group 2. These measurements were repeated at 15-30 second, every minute thereafter up to 5 minutes after airway instrumentation. RESULTS: A statistically significant rise in heart rate, systolic blood pressure, diastolic blood pressure and intraocular pressure was seen in both the groups subsequent to insertion of laryngeal mask airway or endotracheal tube. Mean maximum increase was statistically more after endotracheal intubation than after laryngeal mask airway insertion. The duration of statistically significant pressure responses was also longer after endotracheal intubation. CONCLUSION: Laryngeal mask airway is an acceptable alternative technique for ocular surgeries, offering advantages in terms of intraocular pressure and cardiovascular stability compared to tracheal intubation.

  15. Comparison of a hydrophilic and a hydrophobic apodized diffractive multifocal intraocular lens.

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2013-01-01

    To compare outcomes between a new design apodized diffractive hydrophilic multifocal intraocular lens (IOL) (Seelens MF; study group), and a well-known apodized diffractive hydrophobic multifocal IOL (SN6AD1; control group). A comparative case series comparing refractive and visual outcomes at dista

  16. Clinical comparison of the optical performance of aspheric and spherical intraocular lenses

    NARCIS (Netherlands)

    van Gaalen, Kim W.; Koopmans, Steven A.; Jansonius, Nomdo M.; Kooijman, Aart C.

    2010-01-01

    PURPOSE: To compare the optical performance of aspheric Tecnis ZA9003 and spherical Sensar AR40e intraocular lenses (IOLs). SETTING: Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. METHODS: An aspheric IOL was implan

  17. Uveitis in Thailand : emphasis on clinical patterns and novel developments in diagnostics using intraocular fluid analysis

    NARCIS (Netherlands)

    Pathanapitoon, K.

    2010-01-01

    In this thesis, we report on the so far unknown causes of uveitis in Thailand and describe their clinical manifestations. We found out that intraocular infections were the second most common cause of blindness and low vision in a tertiary center in northern Thailand. These infections predominantly c

  18. The case for intraocular delivery of PPAR agonists in the treatment of diabetic retinopathy.

    LENUS (Irish Health Repository)

    Treacy, Maxwell P

    2012-09-01

    Systemic therapeutics targeting the peroxisome proliferator-activated receptors have been found to be beneficial in the treatment of diabetic retinopathy. In this paper, we provide a rationale for the use of these therapeutics as intraocular agents. In addition, we introduce the peroxisome proliferator-activated receptors and describe their functions in response to the drugs.

  19. Endophthalmitis due to an intra-ocular linear foreign body in a cat

    Directory of Open Access Journals (Sweden)

    Esmeralda Delgado

    2015-05-01

    Full Text Available Case summary An unusual case of an intraocular linear foreign body that migrated from the oral cavity, causing a severe endophthalmitis, in a cat is described. A 2-year-old female domestic shorthair cat presented with signs of infection from the left eye that had begun 2 weeks previously. Despite having been prescribed oral and topical antibiotics, there was a progressive worsening of the clinical signs. On ophthalmic examination the cat presented with severe endophthalmitis, secondary glaucoma and exposure keratitis of the left eye. Radiography demonstrated the presence of an intraocular linear metallic foreign body compatible with a sewing needle. During enucleation, when the globe was extracted, the sewing needle stayed in the orbit. When the needle was pulled away, a piece of thread was also retrieved, which demonstrated that the linear foreign body had migrated retrogradely from the oral cavity to the orbit through the pterygopalatine fossa. Surgical recovery was uneventful. Relevance and novel information Intraocular foreign bodies may present in a variety of ways, which may hinder their clinical detection. The management and prognosis depend on the composition and location of the foreign body, as well as the possible presence of secondary infection. To the author’s knowledge, this is the first time that a case of severe endophthalmitis following retrograde intraocular migration of a linear foreign body from the oral cavity to the orbit through the pterygopalatine fossa in a cat has been reported.

  20. Comparison of ocular straylight after implantation of multifocal intraocular lenses

    NARCIS (Netherlands)

    Łabuz, Grzegorz; Reus, Nicolaas J; van den Berg, Thomas J T P

    2016-01-01

    UNLABELLED: A comprehensive review of the effect of multifocal intraocular lens (IOL) designs on postoperative ocular straylight was performed. Studies reporting straylight values obtained with the natural pupil using the C-Quant device after uneventful multifocal IOL implantation were included. The

  1. X-ray diffraction enhanced imaging study of intraocular tumors in human beings

    International Nuclear Information System (INIS)

    Diffraction enhanced imaging (DEI) with edge enhancement is suitable for the observation of weakly absorbing objects. The potential ability of the DEI was explored for displaying the microanatomy and pathology of human eyeball in this work. The images of surgical specimens from malignant intraocular tumor of hospitalized patients were taken using the hard X-rays from the topography station of Beamline 4W1A at Beijing Synchrotron Radiation Facility (BSRF). The obtained radiographic images were analyzed in correlation with those of pathology. The results show that the anatomic and pathologic details of intraocular tumors in human beings can be observed clearly by DEI for the first time, with good visualization of the microscopic details of eyeball ring such as sclera, choroid and other details of intraocular organelles. And the best resolution of DEI images reaches up to the magnitude of several tens of μm. The results suggest that it is capable of exhibiting clearly the details of intraocular tumor using DEI method. (authors)

  2. Bilateral transient pupil closure after iris supported intraocular lens implantation in a case with Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Necip Kara

    2012-01-01

    Full Text Available A 16-year-old woman presented with Marfan syndrome and bilateral ectopia lentis. The surgical treatment including removal of the crystalline lens and implantation of an iris-supported intraocular lens in both eyes at a week interval. Postoperatively, the biomicroscopic examination showed total pupil closure bilaterally. After the topical tropicamide treatment, the pupil returned to normal shape.

  3. Iris-fixated anterior chamber phakic intraocular lens for myopia moves posteriorly with mydriasis.

    NARCIS (Netherlands)

    Cruysberg, L.P.J.; Doors, M.; Berendschot, T.T.; Brabander, J. De; Webers, C.A.; Nuijts, R.M.

    2009-01-01

    PURPOSE: To elucidate the physiological characteristics of eyes implanted with iris-fixated anterior chamber phakic intraocular lenses (pIOLs), which are increasingly being used for the correction of higher myopic and hyperopic refractive errors. METHODS: In a case series of 20 patients (39 eyes), t

  4. Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Ugur Unsal

    2016-01-01

    Full Text Available Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed. Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later. Results. The corrected and uncorrected distance visual acuity were the same between both groups (p=0.50 and p=0.509, resp.. The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p=0.049, p=0.005, and p=0.001, resp. and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p=0.001. The patient satisfactions of both groups were similar. Conclusion. The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities, whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading.

  5. Fifty-year follow-up and Strampelli anterior chamber intraocular lens.

    Science.gov (United States)

    Oakley, Carmen L; Nigro, Matthew A; Vote, Brendan J

    2015-01-01

    The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era. The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era.

  6. A rapid method for measuring intraocular lens power in vitro with a focimeter.

    Science.gov (United States)

    García-Domene, Mari Carmen; Díez-Ajenjo, María Amparo; Peris-Martínez, Cristina; Navea, Amparo; Artigas, José María

    2015-11-01

    In this paper we describe a new method for measuring the intraocular lens (IOL) power using a focimeter, a negative ophthalmic lens and a saline solution (0.9% NaCl). To test this we measured the power of 58 different IOLs and we compared them with the power stated by the manufacturer. Despite the limitations, the results show a good correlation.

  7. CORRECTION OF HIGH MYOPIA WITH THE WORST MYOPIA CLAW INTRAOCULAR-LENS

    NARCIS (Netherlands)

    LANDESZ, M; WORST, JGF; SIERTSEMA, JV; VANRIJ, G

    1995-01-01

    BACKGROUND: Phakic anterior chamber lenses is one of the modalities used to correct high myopia, We report the initial results of our prospective study on the Worst myopia claw intraocular lens (IOL) that is fixated to the anterior iris, METHODS: We studied 35 eyes in 18 patients with a preoperative

  8. Case of late-onset corneal decompensation after iris-fixated phakic intraocular lens implantation.

    NARCIS (Netherlands)

    Eijden, R. van; Vries, N.E. de; Cruysberg, L.P.J.; Webers, C.A.; Berenschot, T.; Nuijts, R.M.

    2009-01-01

    A 48-year-old myopic patient with bilateral anterior chamber depth of 3.1 mm and endothelial cell density (ECD) of 2525 cells/mm(2) and 2638 cells/mm(2) preoperatively had bilateral implantation of an Artisan iris-fixated phakic intraocular lens (pIOL). Five years postoperatively, unilateral corneal

  9. Intraocular pressure-lowering effect of oral paracetamol and its in vitro corneal penetration properties

    Directory of Open Access Journals (Sweden)

    Mohamed N

    2013-01-01

    Full Text Available Nabiel Mohamed, David MeyerDivision of Ophthalmology, Faculty of Medicine and Health Sciences, University of Stellenbosch, Cape Town, South AfricaBackground: Several studies have confirmed the ability of cannabinoids to reduce intraocular pressure. Experimental data recently demonstrated unequivocally that the analgesic effect of paracetamol is due to its indirect action on cannabinoid receptors. The question then arises as to whether paracetamol can reduce intraocular pressure via its effect on intraocular cannabinoid receptors.Methods: A 2-week, prospective, randomized, controlled, single-center, parallel-group pilot study was carried out to determine the efficacy and safety of paracetamol 1 g orally administered every 6 hours in adult patients with primary or secondary open angle glaucoma as compared with topical levobunolol 0.5% twice a day. Patient well-being was closely monitored throughout the study and focused on hepatic safety in accordance with Drug-Induced Liver Injury Network criteria. The in vitro diffusion kinetics of acetaminophen in a phosphate-buffered solution in rabbit and human corneas was also investigated, with the view to a topical application.Results: Eighteen adult patients were enrolled in the study, with nine in the topical levobunolol group and nine in the oral paracetamol group. In the levobunolol group, the mean reduction in intraocular pressure at day 7 was 7.5 mmHg (P < 0.008 and at day 14 was 9.1 mmHg (P < 0.005, from a mean baseline intraocular pressure of 29.6 mmHg. The corresponding figures for the paracetamol group were 8.8 mmHg (P < 0.0004 at day 7 and 6.5 mmHg (P < 0.004 at day 14, from a mean baseline intraocular pressure of 29.4 mmHg. Both study regimens were well tolerated. No serious treatment-related adverse events were reported in either of the treatment groups. Liver function tests, systolic/diastolic blood pressure, or heart rate remained unchanged in both groups during the 2 weeks of the study. In

  10. ElevationDEM_CCLIDARDEM

    Data.gov (United States)

    Vermont Center for Geographic Information — Digital Elevation Model (DEM) derived from the 2004 Chittenden bare earth LiDAR data. The pixel size of this layer is 3.2m, equal to the spacing of the filtered...

  11. Elevator Control Strategies

    OpenAIRE

    Ceder, Frederick; Nordin, Alexandra

    2013-01-01

    This paper investigates the efficiency of known elevator control strategies by simulating these in an own made apartment simulator. Efficiency will be determined by the lowest product of the energy consumption (Watt/second), average waiting time, average transfer time and the maximum waiting time of a passenger, which is the output by the simulator. The apartment simulator will simulate the elevator behavior, according to a respective control strategy, and the passenger flow on each respectiv...

  12. Interaktive tavler - interaktive elever

    DEFF Research Database (Denmark)

    Otzen, Elsebeth; Reusch, Charlotte

    Abstract, Poster-præsentation 13.-14. juni 2012, Pilotprojekt: Interaktive tavler ? interaktive elever Hvordan motiverer en interaktiv tavle lærere og elever? Hvad sker der mellem elev, stof og lærer, når læreren bliver i stand til at billedliggøre og dynamisere sine oplæg på tavlen? Bliver...... læreroplæg prioriteret? Bliver eleverne aktive, eller ender den interaktive tavle med blot at understøtte lærerens envejskommunikation til klassen? Og hvad sker der mellem eleverne? Disse spørgsmål var igangsættende for arbejdet med pilotprojektet Interaktive tavler ? interaktive elever, som blev afviklet i...... klasserumsobservation og kvalitative interviews med lærere og elever på en skole i København. To hypoteser: Den interaktive tavle påkalder sig opmærksomheden og kan derfor motivere elever til at gøre en ekstra indsats i skolearbejde. Den interaktive tavle vil få læreren til at vægte egne oplæg foran tavlen i...

  13. Artificial muscles on heat

    Science.gov (United States)

    McKay, Thomas G.; Shin, Dong Ki; Percy, Steven; Knight, Chris; McGarry, Scott; Anderson, Iain A.

    2014-03-01

    Many devices and processes produce low grade waste heat. Some of these include combustion engines, electrical circuits, biological processes and industrial processes. To harvest this heat energy thermoelectric devices, using the Seebeck effect, are commonly used. However, these devices have limitations in efficiency, and usable voltage. This paper investigates the viability of a Stirling engine coupled to an artificial muscle energy harvester to efficiently convert heat energy into electrical energy. The results present the testing of the prototype generator which produced 200 μW when operating at 75°C. Pathways for improved performance are discussed which include optimising the electronic control of the artificial muscle, adjusting the mechanical properties of the artificial muscle to work optimally with the remainder of the system, good sealing, and tuning the resonance of the displacer to minimise the power required to drive it.

  14. Artificial vision workbench.

    Science.gov (United States)

    Frenger, P

    1997-01-01

    Machine vision is an important component of medical systems engineering. Inexpensive miniature solid state cameras are now available. This paper describes how these devices can be used as artificial retinas, to take snapshots and moving pictures in monochrome or color. Used in pairs, they produce a stereoscopic field of vision and enable depth perception. Macular and peripheral vision can be simulated electronically. This paper also presents the author's design of an artificial orbit for this synthetic eye. The orbit supports the eye, protects it, and provides attachment points for the ocular motion control system. Convergence and image fusion can be produced, and saccades simulated, along with the other ocular motions. The use of lenses, filters, irises and focusing mechanisms are also discussed. Typical camera-computer interfaces are described, including the use of "frame grabbers" and analog-to-digital image conversion. Software programs for eye positioning, image manipulation, feature extraction and object recognition are discussed, including the application of artificial neural networks.

  15. Artificial intelligence in nanotechnology.

    Science.gov (United States)

    Sacha, G M; Varona, P

    2013-11-15

    During the last decade there has been increasing use of artificial intelligence tools in nanotechnology research. In this paper we review some of these efforts in the context of interpreting scanning probe microscopy, the study of biological nanosystems, the classification of material properties at the nanoscale, theoretical approaches and simulations in nanoscience, and generally in the design of nanodevices. Current trends and future perspectives in the development of nanocomputing hardware that can boost artificial-intelligence-based applications are also discussed. Convergence between artificial intelligence and nanotechnology can shape the path for many technological developments in the field of information sciences that will rely on new computer architectures and data representations, hybrid technologies that use biological entities and nanotechnological devices, bioengineering, neuroscience and a large variety of related disciplines.

  16. Artificial intelligence in nanotechnology

    International Nuclear Information System (INIS)

    During the last decade there has been increasing use of artificial intelligence tools in nanotechnology research. In this paper we review some of these efforts in the context of interpreting scanning probe microscopy, the study of biological nanosystems, the classification of material properties at the nanoscale, theoretical approaches and simulations in nanoscience, and generally in the design of nanodevices. Current trends and future perspectives in the development of nanocomputing hardware that can boost artificial-intelligence-based applications are also discussed. Convergence between artificial intelligence and nanotechnology can shape the path for many technological developments in the field of information sciences that will rely on new computer architectures and data representations, hybrid technologies that use biological entities and nanotechnological devices, bioengineering, neuroscience and a large variety of related disciplines. (topical review)

  17. Artificial intelligence in nanotechnology

    Science.gov (United States)

    Sacha, G. M.; Varona, P.

    2013-11-01

    During the last decade there has been increasing use of artificial intelligence tools in nanotechnology research. In this paper we review some of these efforts in the context of interpreting scanning probe microscopy, the study of biological nanosystems, the classification of material properties at the nanoscale, theoretical approaches and simulations in nanoscience, and generally in the design of nanodevices. Current trends and future perspectives in the development of nanocomputing hardware that can boost artificial-intelligence-based applications are also discussed. Convergence between artificial intelligence and nanotechnology can shape the path for many technological developments in the field of information sciences that will rely on new computer architectures and data representations, hybrid technologies that use biological entities and nanotechnological devices, bioengineering, neuroscience and a large variety of related disciplines.

  18. Experimental differentiation of intraocular masses using ultrahigh-field magnetic resonance imaging--a case series.

    Directory of Open Access Journals (Sweden)

    Karen Falke

    Full Text Available PURPOSE: The case reports presented here were compiled to demonstrate the potential for improved diagnosis and monitoring of disease progress of intraocular lesions using ultrahigh-field magnetic resonance microscopy (MRM at 7.1 Tesla. METHODS: High-resolution ex vivo ocular magnetic resonance (MR images were acquired on an ultrahigh-field MR system (7.1 Tesla, ClinScan, Bruker BioScan, Germany using a 2-channel coil with 4 coil elements and T2-weighted turbo spin echo (TSE sequences of human eyes enucleated because of different intraocular lesions. Imaging parameters were: 40×40 mm field of view, 512×512 matrix, and 700 µm slice thickness. The results were correlated with in vivo ultrasound and histology of the enucleated eyes. RESULTS: Imaging was performed in enucleated eyes with choroidal melanoma, malignant melanoma of iris and ciliary body with scleral perforation, ciliary body melanoma, intraocular metastasis of esophageal cancer, subretinal bleeding in the presence of perforated corneal ulcer, hemorrhagic choroidal detachment, and premature retinopathy with phthisis and ossification of bulbar structures. MR imaging allowed differentiation between solid and cystic tumor components. In case of hemorrhage, fluid-fluid levels were identified. Melanin and calcifications caused significant hypointensity. Microstructural features of eye lesions identified by MRM were confirmed by histology. CONCLUSION: This study demonstrates the potential of MRM for the visualization and differential diagnosis of intraocular lesions. At present, the narrow bore of the magnet still limits the use of this technology in humans in vivo. Further advances in ultrahigh-field MR imaging will permit visualization of tumor extent and evaluation of nonclassified intraocular structures in the near future.

  19. Artificial human vision.

    Science.gov (United States)

    Dowling, Jason

    2005-01-01

    Can vision be restored to the blind? As early as 1929 it was discovered that stimulating the visual cortex of an individual led to the perception of spots of light, known as phosphenes [1] . The aim of artificial human vision systems is to attempt to utilize the perception of phosphenes to provide a useful substitute for normal vision. Currently, four locations for electrical stimulation are being investigated; behind the retina (subretinal), in front of the retina (epiretinal), the optic nerve and the visual cortex (using intra- and surface electrodes). This review discusses artificial human vision technology and requirements, and reviews the current development projects.

  20. Spatially Resolved Artificial Chemistry

    DEFF Research Database (Denmark)

    Fellermann, Harold

    2009-01-01

    Although spatial structures can play a crucial role in chemical systems and can drastically alter the outcome of reactions, the traditional framework of artificial chemistry is a well-stirred tank reactor with no spatial representation in mind. Advanced method development in physical chemistry has...... made a class of models accessible to the realms of artificial chemistry that represent reacting molecules in a coarse-grained fashion in continuous space. This chapter introduces the mathematical models of Brownian dynamics (BD) and dissipative particle dynamics (DPD) for molecular motion and reaction...

  1. Bayesian artificial intelligence

    CERN Document Server

    Korb, Kevin B

    2003-01-01

    As the power of Bayesian techniques has become more fully realized, the field of artificial intelligence has embraced Bayesian methodology and integrated it to the point where an introduction to Bayesian techniques is now a core course in many computer science programs. Unlike other books on the subject, Bayesian Artificial Intelligence keeps mathematical detail to a minimum and covers a broad range of topics. The authors integrate all of Bayesian net technology and learning Bayesian net technology and apply them both to knowledge engineering. They emphasize understanding and intuition but also provide the algorithms and technical background needed for applications. Software, exercises, and solutions are available on the authors' website.

  2. Clinical observation on cataract with lens subluxation treated by phacoemulsification combined with intraocular lens implanta-tion%晶状体不全脱位白内障超声乳化手术临床观察

    Institute of Scientific and Technical Information of China (English)

    原文新; 曲端; 郭哲锋

    2013-01-01

    目的:观察超声乳化白内障吸出联合人工晶体植入术治疗晶状体不全脱位白内障的疗效及安全性。方法对56例(60眼)晶状体不全脱位白内障患者采用超声乳化白内障吸出术,人工晶状体固定方式采用睫状沟缝线固定或囊袋内植入,观察术后视力及并发症等情况。结果56例(60眼)病例脱位晶状体均顺利取出,并植入人工晶状体,视力均有不同程度提高。结论超声乳化白内障吸出联合人工晶状体植入术治疗晶状体不全脱位白内障是安全有效的。%Objective To observe the efficacy and safety of phacoe-mulsification combined with intraocular lens implantation for the treatment of cataract with lens subluxation. Methods 56cases (60eyes) cataract with lens subluxation were operated by phacoemulsification,intraocular lens were fixed in ciliary sulcus with sutures or implanted in the capsular bag. The visual acuity and the postoperative complications were observed and analyzed. Results 56 cases (60 eyes) cases of dislocated lens were removed successfully,with implantation of artificial lens,visual acuity was improved in different degree. Conclusion Phacoemulsifi-cation combined with intraocular lens implantation for the treatment of dislocated lens cataract is safe and effective.

  3. Artificial intelligence within AFSC

    Science.gov (United States)

    Gersh, Mark A.

    1990-01-01

    Information on artificial intelligence research in the Air Force Systems Command is given in viewgraph form. Specific research that is being conducted at the Rome Air Development Center, the Space Technology Center, the Human Resources Laboratory, the Armstrong Aerospace Medical Research Laboratory, the Armamant Laboratory, and the Wright Research and Development Center is noted.

  4. Artificial Left Ventricle

    CERN Document Server

    Ranjbar, Saeed; Meybodi, Mahmood Emami

    2014-01-01

    This Artificial left ventricle is based on a simple conic assumption shape for left ventricle where its motion is made by attached compressed elastic tubes to its walls which are regarded to electrical points at each nodal .This compressed tubes are playing the role of myofibers in the myocardium of the left ventricle. These elastic tubes have helical shapes and are transacting on these helical bands dynamically. At this invention we give an algorithm of this artificial left ventricle construction that of course the effect of the blood flow in LV is observed with making beneficiary used of sensors to obtain this effecting, something like to lifegates problem. The main problem is to evaluate powers that are interacted between elastic body (left ventricle) and fluid (blood). The main goal of this invention is to show that artificial heart is not just a pump, but mechanical modeling of LV wall and its interaction with blood in it (blood movement modeling) can introduce an artificial heart closed to natural heart...

  5. Artificial Gravity Research Plan

    Science.gov (United States)

    Gilbert, Charlene

    2014-01-01

    This document describes the forward working plan to identify what countermeasure resources are needed for a vehicle with an artificial gravity module (intermittent centrifugation) and what Countermeasure Resources are needed for a rotating transit vehicle (continuous centrifugation) to minimize the effects of microgravity to Mars Exploration crewmembers.

  6. Micromachined Artificial Haircell

    Science.gov (United States)

    Liu, Chang (Inventor); Engel, Jonathan (Inventor); Chen, Nannan (Inventor); Chen, Jack (Inventor)

    2010-01-01

    A micromachined artificial sensor comprises a support coupled to and movable with respect to a substrate. A polymer, high-aspect ratio cilia-like structure is disposed on and extends out-of-plane from the support. A strain detector is disposed with respect to the support to detect movement of the support.

  7. Terahertz Artificial Dielectric Lens

    Science.gov (United States)

    Mendis, Rajind; Nagai, Masaya; Wang, Yiqiu; Karl, Nicholas; Mittleman, Daniel M.

    2016-03-01

    We have designed, fabricated, and experimentally characterized a lens for the THz regime based on artificial dielectrics. These are man-made media that mimic properties of naturally occurring dielectric media, or even manifest properties that cannot generally occur in nature. For example, the well-known dielectric property, the refractive index, which usually has a value greater than unity, can have a value less than unity in an artificial dielectric. For our lens, the artificial-dielectric medium is made up of a parallel stack of 100 μm thick metal plates that form an array of parallel-plate waveguides. The convergent lens has a plano-concave geometry, in contrast to conventional dielectric lenses. Our results demonstrate that this lens is capable of focusing a 2 cm diameter beam to a spot size of 4 mm, at the design frequency of 0.17 THz. The results further demonstrate that the overall power transmission of the lens can be better than certain conventional dielectric lenses commonly used in the THz regime. Intriguingly, we also observe that under certain conditions, the lens boundary demarcated by the discontinuous plate edges actually resembles a smooth continuous surface. These results highlight the importance of this artificial-dielectric technology for the development of future THz-wave devices.

  8. Observations of artificial satellites

    Directory of Open Access Journals (Sweden)

    A. MAMMANO

    1964-06-01

    Full Text Available The following publication gives the results of photographic
    observations of artificial satellites made at Asiago during the second
    and third year of this programme. The fixed camera technique and that
    with moving film (the latter still in its experimental stage have been used.

  9. Effects of short-term IOP elevation on receptive field properties of cat LGN cells

    Institute of Scientific and Technical Information of China (English)

    TAO Liming; ZHANG Nan; YE Xiang; ZHOU Yifeng

    2004-01-01

    To investigate the effects of short-term intraocular pressure (IOP) elevation on the receptive field properties of lateral geniculate nucleus (LGN) cells, responses of the LGN cells to annulus, disc and drifting gratings with high or low spatial frequencies have been recorded extracellularly in the cat with the retinal perfusion pressure kept stable (30mmHg). Our results indicated that the responses of the X and Y type LGN cells were significantly weakened during IOP elevation. And the responses varied with the different mechanisms of receptive fields. Specifically, while using annulus and disc as stimuli, the responses of Y cells were more tolerant than X cells to IOP elevation. The surround area of the receptive field was more sensitive to IOP elevation than the center. The mean responses during IOP elevation decreased more than the peak responses did. IOP elevation has more influence on the responses of X cells than on the response of Y cells to the drifting gratings with high spatial frequency. These results may reflect different degrees of ischemia on corresponding retinal structures caused by IOP elevation.

  10. Introduction to Artificial Neural Networks

    DEFF Research Database (Denmark)

    Larsen, Jan

    1999-01-01

    The note addresses introduction to signal analysis and classification based on artificial feed-forward neural networks.......The note addresses introduction to signal analysis and classification based on artificial feed-forward neural networks....

  11. [The effect of crystalline lens extraction on intraocular pressure in patients with primary open-angle glaucoma].

    Science.gov (United States)

    Macarie, S; Macarie, Daniela

    2013-01-01

    This issue presents the results of a study on patients with cataract and primary open angle glaucoma who suffered lens extraction for cataract. We analise the effects of the lens extraction on the level of intraocular pressure at this patients.

  12. Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Ya-wen Guo

    2014-01-01

    Full Text Available Purpose. To investigate the intraocular straylight value after cataract surgery. Methods. In this study, 76 eyes from 62 patients were subdivided into three groups. A hydrophobic acrylic, a hydrophilic acrylic, and a PMMA IOL were respectively, implanted in 24 eyes, 28 eyes, and 24 eyes. Straylight was measured using C-Quant at 1 week and 1 month postoperatively in natural and dilated pupils. Results. The hydrophilic acrylic IOLs showed significantly lower straylight values than those of the hydrophobic acrylic IOLs in dilated pupils at 1 week and 1 month after surgery (P0.05. Moreover, no significant difference was found in straylight between natural and dilated pupils in each group at 1 week and 1 month postoperatively (P>0.05. Conclusions. Although the hydrophobic acrylic IOL induced more intraocular straylight, straylight differences among the 3 IOLs were minimal. Pupil size showed no effect on intraocular straylight; the intraocular straylight was stable 1 week after surgery.

  13. Combined Surgical Approach of Pars Plana Vitrectomy, Phacoemulsification, and Intraocular Lens Implantation for the Management of Cataract and Posterior Segment Pathologies

    Directory of Open Access Journals (Sweden)

    Cem Özgönül

    2014-03-01

    Full Text Available Objectives: To evaluate the indications, intra- and post-operative complications, and visual results of combined cataract surgery and pars plana vitrectomy. Materials and Methods: Medical records of patients who underwent combined surgery between January 2008 and January 2011 were retrospectively evaluated. Indications for surgery, complications, pre-operative and post-operative visual acuities were recorded. Results: Sixty-four eyes of 64 patients were included in the study. Thirty-five (55% of the patients were men and 29 (45% were women; mean age was 53±21 (6-88 years. Mean follow-up time was 13±12 (1-51 months. The main indications for combined surgery were intravitreal hemorrhage in 19 patients (29.7%, epiretinal membrane in 12 (18.8%, intraocular foreign body in 11 (17.2%, retinal detachment in 9 (14.1%, and macular edema in 7 (11% patients. Posterior capsule rupture in 3 cases and corneal edema in 2 cases were the complications encountered during surgery. Postoperatively, hypotonia occurred in 5 cases and corneal edema in 1. Intraocular pressure elevation was observed in 1 silicon-injected case and 1 propane gas-injected case. The average preoperative visual acuity was 1.90±1.9 (0.22 to 3.10 LogMAR. The average postoperative visual acuity at the last visit was 1.1±1.0 (0.00 to 4.00 LogMAR. The visual acuity increase was statistically significant (p<0.001. Conclusion: Combined surgery is a feasible option for patients with vitreoretinal diseases and cataract. Visual results and complications depend primarily on the underlying posterior segment pathology. (Turk J Ophthalmol 2014; 44: 98-101

  14. Linfoma intra-ocular primário de células tipo B: relato de caso Primary intraocular B-cell lymphoma: case report

    Directory of Open Access Journals (Sweden)

    Marcela Cypel

    2007-08-01

    Full Text Available O linfoma não-Hodgkin primariamente intra-ocular é raro, e caracterizado por uma forma extranodal que pode envolver retina, espaço sub-retiniano, vítreo e nervo óptico. Ocorre independente ou associado ao linfoma do sistema nervoso central e freqüentemente na forma de uveíte de difícil tratamento. Esta forma de linfoma é um dos tumores intra-oculares mais desafiantes de se diagnosticar. Relatamos um caso de linfoma não-Hodgkin intra-ocular difuso de células grandes tipo B numa paciente de 47 anos e cuja manifestação inicial foi uma uveíte posterior; enfatizamos a importância de investigação detalhada e da avaliação sistêmica; pois esta é a forma mais freqüente de acometimento ocular. Com esse relato esperamos abordar os principais aspectos desde quadro clínico até diagnóstico chamando a atenção para essa doença que muitas vezes aparece inicialmente com sintomas vagos e inespecíficos.Ocular non-Hodgkin's lymphoma is a rare condition that can involve the retina, the vitreous and the optic nerve. It can occur alone or can be associated with lymphoma of the central nervous system and a frequent manifestation is a posterior uveitis of difficult treatment. This kind of ocular tumor is difficult and a challenge to diagnosis. We describe a case of non-Hodgkin's intraocular B-cell lymphoma in a 47-year-old woman who had a posterior uveitis as the first manifestation. We emphasize the importance of a careful investigation and of the general clinical examination since this is the most common type in the eye. We expect to call the attention to this disease that many times appears in an unspecific form with unspecific symptoms.

  15. INTRAOCULAR TRANSMISSIBLE VENEREAL TUMOR IN A DOG TUMOR VENÉREO TRANSMISSÍVEL INTRA-OCULAR EM CÃO

    Directory of Open Access Journals (Sweden)

    Geórgia Nadalini Rodrigues

    2001-02-01

    Full Text Available Canine transmissible venereal tumor (TVT is a round cell neoplasm occurring on the external genital mucosa of male and female dogs. Transmission is by cell implantation during coitus, licking, or other interaction between an affected dog and a susceptible host. Metastasis of the tumor rarely occurs. This report describes an unusual presentation of TVT with intraocular involvement and inguinal lymph nodes metastasis. The subject was a six-year-old, intact, male, Brazilian Terrier dog with a history of abnormal masses in the right eye, penis and several subcutaneous nodules in the inguinal area. Histopathological examination of the eye specimens as well as cytologic examination of penile mass and subcutaneous nodules revealed similar findings. The examination revealed round cells containing a large nuclei with prominent, central located nucleoli and a pale cytoplasm containing few small, clear round vacuoles. Histologically, the subcutaneous nodules in the inguinal area were lymph nodes. The diagnosis of TVT with intraocular involvement and lymph nodes metastasis was based on clinical, cytologic and histopathologic findings.Tumor venéreo transmissível (TVT é uma neoplasia de células redondas que acomete a mucosa genital externa de cães, machos e fêmeas. A transmissão decorre da implantação de células tumorais durante o coito, brigas ou interações entre animais portadores e susceptíveis. Existem relatos referindo-se a localizações atípicas do TVT, mas metástases raramente ocorrem. O presente relato descreve um caso incomum de TVT, com acometimento intra-ocular e metástases nos linfonodos ingüinais, num cão Terrier Brasileiro, com seis anos de idade. O animal apresentava massas anormais de tecido no olho direito, extremidade do pênis e aumento de volume de linfonodos da região ingüinal. A histopatologia do globo ocular e as citologias da massa peniana e dos nódulos subcutâneos evidenciaram aspectos citológicos semelhantes

  16. Interaktive tavler - interaktive elever

    DEFF Research Database (Denmark)

    Reusch, Charlotte F.; Otzen, Elsebeth

    2012-01-01

    Abstract, Poster-præsentation 13.-14. juni 2012, Pilotprojekt: Interaktive tavler – interaktive elever Lektor, cand. pæd., Elsebeth Otzen og Lektor, cand. mag., Charlotte Reusch, Institut for Skole og Læring, Læreruddannelsen, Professionshøjskolen Metropol, København Hvordan motiverer en interaktiv...... tavle lærere og elever? Hvad sker der mellem elev, stof og lærer, når læreren bliver i stand til at billedliggøre og dynamisere sine oplæg på tavlen? Bliver læreroplæg prioriteret? Bliver eleverne aktive, eller ender den interaktive tavle med blot at understøtte lærerens envejskommunikation til klassen......? Og hvad sker der mellem eleverne? Disse spørgsmål var igangsættende for arbejdet med pilotprojektet Interaktive tavler – interaktive elever, som blev afviklet i skoleåret 2010-2011. Projektet blev udført af en tværfaglig gruppe, bestående af lektorer i matematik, biologi og dansk i læreruddannelsen...

  17. Interaktive tavler - interaktive elever

    DEFF Research Database (Denmark)

    Reusch, Charlotte; Otzen, Elsebeth

    2012-01-01

    Abstract, Poster-præsentation 13.-14. juni 2012, Pilotprojekt: Interaktive tavler ? interaktive elever Lektor, cand. pæd., Elsebeth Otzen og Lektor, cand. mag., Charlotte Reusch, Institut for Skole og Læring, Læreruddannelsen, Professionshøjskolen Metropol, København Hvordan motiverer en interaktiv...... tavle lærere og elever? Hvad sker der mellem elev, stof og lærer, når læreren bliver i stand til at billedliggøre og dynamisere sine oplæg på tavlen? Bliver læreroplæg prioriteret? Bliver eleverne aktive, eller ender den interaktive tavle med blot at understøtte lærerens envejskommunikation til klassen......? Og hvad sker der mellem eleverne? Disse spørgsmål var igangsættende for arbejdet med pilotprojektet Interaktive tavler ? interaktive elever, som blev afviklet i skoleåret 2010-2011. Projektet blev udført af en tværfaglig gruppe, bestående af lektorer i matematik, biologi og dansk i læreruddannelsen...

  18. Udeskole og elevers handlekompetence

    DEFF Research Database (Denmark)

    Breiting, Søren

    2011-01-01

    Elever elsker at komme væk fra undervisningen i skolen. Er det positivt eller negativt? Og hvad har betydning for, at eleverne får mest muligt ud af oplevelserne uden for skolen? Forskellige former for udeskole giver nogle oplagte muligheder, så eleverne udvikler sig som engagerede borgere i et...

  19. Thinning in artificially regenerated young beech stands

    Directory of Open Access Journals (Sweden)

    Novák Jiří

    2015-12-01

    Full Text Available Although beech stands are usually regenerated naturally, an area of up to 5,000 ha year−1 is artificially regenerated by beech in the Czech Republic annually. Unfortunately, these stands often showed insufficient stand density and, consequently, lower quality of stems. Therefore, thinning methods developed for naturally regenerated beech stands are applicable with difficulties. The paper evaluates the data from two thinning experiments established in young artificially regenerated beech stands located in different growing conditions. In both experiments, thinning resulted in the lower amount of salvage cut in following years. Positive effect of thinning on periodic stand basal area increment and on periodic diameter increment of dominant trees was found in the beech stand located at middle elevations. On the other hand, thinning effects in mountain conditions were negligible. Thinning focusing on future stand quality cannot be commonly applied in artificially regenerated beech stands because of their worse initial quality and lower density. However, these stands show good growth and response to thinning, hence their management can be focused on maximising beech wood production.

  20. Biocompatibility of intraocular lens materials%人工晶体材料的生物相容性特征★

    Institute of Scientific and Technical Information of China (English)

    王洋; 韩宏光

    2013-01-01

      BACKGROUND: The visual recovery and complications of the cataract patients are various after different intraocular lens materials implantation, so the selection of appropriate intraocular lens materials is the key of the research. OBJECTIVE: To investigate the properties and biocompatibility of intraocular lens materials. METHODS: The materials were classified according to the hardness and location of the intraocular lens after implantation in order to analyze the pros and cons of the intraocular lens thus guiding the patients to select the appropriate intraocular lens for implantation. The properties and biocompatibility of the commonly used intraocular lens materials were evaluated. RESUTLS AND CONCLUSION: Polymethylmethacrylate intraocular lens is the first choice of rigid material, but it cannot tolerate autoclaving. Acrylic intraocular lens is the soft and foldable intraocular lens that has the similar optical and biological properties with polymethylmethacrylate intraocular lens, and it can improve the visual acuity after implantation with less complications. Posterior capsular opacification is the most important indicator for biocompatibility evaluation which is related with the material and design of intraocular lens. The stability of intraocular lens in the capsular bag is also the indicator to evaluate the biocompatibility. The material properties, biocompatibility, and visual function should be taking into consideration in the design and selection of intraocular lens materials. Guarantee the efficacy after intraocular lens implantation and reduce the incidence of complications, so that to get vision rehabilitation for the cataract patients.%  背景:白内障患者植入不同材料人工晶体治疗后的视力恢复情况和并发症有所不同,选择适宜的人工晶体材料是研究的关键。目的:探讨人工晶体材料的特征和生物相容性。方法:按人工晶体的硬度和植入后不同位置将材料进行分类

  1. Development of a hydrophobic polymer composition with improved biocompatibility for making foldable intraocular lenses

    Science.gov (United States)

    Haldar, R. S.; Chauhan, R.; Kapoor, K.; Niyogi, U. K.

    2014-05-01

    A hydrophobic composition for foldable intraocular lenses was developed by copolymerizing phenyl ethyl acrylate, phenyl ethyl methacrylate and butanediol diacrylate by gamma irradiation. Aqueous solution of heparin, a biocompatibilizer absorbed in hydroxyethyl methacrylate was added to the monomer mixture before irradiation to impart desired level of hydrophilicity and improved biocompatibility to the hydrophobic composition. Ketorolac tromethamine, an anti-inflammatory agent and L-glutathione, an antioxidant were added to the composition as functional additive for exhibiting improved performance while in use. Concentrations of monomers, biocompatibilizer and functional additives were optimized to develop an advanced material for foldable intraocular lenses. Transmittance, refractive index, Abbe number, hardness, tensile strength, flexibility and foldability were studied on the final composition. Scanning electron microscopic study, differential scanning calorimetric analysis, leachability and viscometry confirmed the permanent incorporation of additives into the polymer. Results of haemocompatibility, tissue implantation and cytotoxicity confirm that the biocompatibility of the base polymer was improved by incorporation of heparin.

  2. "Effect of topical timolol on intraocular pressure in the presence of systemic indomethacin in normal subjects"

    Directory of Open Access Journals (Sweden)

    Sud R

    1988-01-01

    Full Text Available In the present study on 60 normal subjects, the effect of 0.5% timolol eye drops on intraocular tension was assessed in the presence of oral indomethacin. The subjects were categorized in four groups for comparing the results. Also the side effects of timolol maleate were noted. The following conclusions were made:- 1. In cases in whom indomethacin was given along with timolol drops, average fall in intraocular tension was almost identical with those in whom timolol alone was used. 2. The ocular hypotensive effect of timolol maleate eve drops is not attenuated by indomethacin given orally; but before we can conclude that the simultaneous administration of timolol maleate eye drops and indomethacin is entirely without risk of attenuation. We must study the effect of combined administration in patients with glaucoma.

  3. Closure of a persistent cyclodialysis cleft using the haptics of a normal-sized intraocular lens.

    Science.gov (United States)

    Shentu, Xingchao; Zhu, Yanan; Tang, Yelei

    2011-11-01

    A 50-year-old man suffering from hypotony in the right eye caused by a traumatic cyclodialysis and complicated by a choroidal detachment and cataract was treated in our clinic. After an unsuccessful direct cyclopexy, phacoemulsification was performed and a normal-sized single-piece polymethyl methacrylate posterior chamber intraocular lens (PMMA PCIOL) was inserted into the ciliary sulcus, with the haptic rotated toward the cyclodialysis cleft. Postoperatively, the corrected visual acuity improved to 20/20, and the intraocular pressure returned to normal. Ultrasound biomicroscopy showed the closure of the cleft. Phacoemulsification with a normal-sized PMMA PCIOL inserted into the ciliary sulcus is a safe, effective and technically simple surgical treatment for small cyclodialysis induced hypotony complicated by cataract. Internal compression of the cleft by the haptic of a normal sized IOL along with postoperative inflammation led to scarring and closure of the cleft.

  4. Effects of intraocular mescaline and LSD on visual-evoked responses in the rat.

    Science.gov (United States)

    Eells, J T; Wilkison, D M

    1989-01-01

    The effects of mescaline and LSD on the flash-evoked cortical potential (FEP) were determined in unrestrained rats with chronically-implanted electrodes. Systemic administration of mescaline or LSD significantly attenuated the primary component of the FEP at three stimulus intensities with the greatest effect observed 60-90 minutes following drug administration. The magnitude and specificity of the effects of these agents on the primary response suggest that they produce deficits in conduction through the retino-geniculato-cortical system. The serotonin receptor antagonists, cyproheptadine and methysergide, antagonized the mescaline-induced depression of the FEP in accordance with neurochemical and behavioral evidence that mescaline acts as a partial agonist on serotonin receptors. Topical or intraocular administration of atropine antagonized the actions of systemically-administered mescaline. In addition, intraocular administration of mescaline or LSD attenuated the FEP indicative of an action of these hallucinogens on visual processing in the retina which is modulated by muscarinic receptor activity.

  5. Delivery of Intraocular Triamcinolone Acetonide in the Treatment of Macular Edema

    Directory of Open Access Journals (Sweden)

    Brent Siesky

    2012-03-01

    Full Text Available Macular edema (ME is one of the eventual outcomes of various intraocular and systemic pathologies. The pathogenesis for ME is not yet entirely understood; however, some of the common risk factors for its development have been identified. While this investigation will not discuss the numerous etiologies of ME in detail, it appraises the two most widely studied delivery modalities of intraocular corticosteroids in the treatment of ME—intravitreal injection (IVI and sub-Tenon’s infusion (STI. A thorough review of the medical literature was conducted to identify the efficacy and safety of IVI and STI, specifically for the administration of triamcinolone acetonide (TA, in the setting of ME in an attempt to elucidate a preferred steroid delivery modality for treatment of ME.

  6. The Changes of Quality of Life in the Patients after Phacoemulsification with Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Jiewei Liu; Jingjing Xu; Mingguang He

    2004-01-01

    Purpose: To investigate the improvement and maintenance of the quality of life in the patients after phacoemulsification with intraocular lens implantation.Methods :The study population consisted of 116 patients receiving phacoemulsification with intraocular lens implantation. They were interviewed using the quality of life questionnaire, and the clinical outcomes were evaluated before surgery and at 1 week, 1month, 3 months, 6 months after surgery respectively.Results:Patients reported similar scores of quality of life and all the four subscales among 1-week, 1-month , 3-month and 6-month follow-up visit after surgery, all of which were higher than the scores before surgery.Conclusion: Patients receiving phacoemulsification reported rapid improvement in quality of life after surgery, and the quality of life scores were not changed significantly from 1week to 6 months after surgery.

  7. Implantation of iris-claw Artisan intraocular lens for aphakia in Fuchs′ heterochromic iridocyclitis

    Directory of Open Access Journals (Sweden)

    Ahmad Kheirkhah

    2014-01-01

    Full Text Available Implantation of iris-claw Artisan intraocular lens (IOL is a surgical option for correction of aphakia; however, these IOLs have not been used in eyes with uveitis including Fuchs′ heterochromic iridocyclitis (FHI due to possible risk of severe postoperative intraocular inflammation. In the case reported here, we secondarily implanted an Artisan IOL in a 28-year-old man with FHI who had aphakia with no capsular support due to a previous complicated cataract surgery. Enclavation was easily performed and no intraoperative complication was noted. Postoperative course was uneventful with no significant anterior chamber inflammation during 12 months of follow-up. Although there were few deposits on the IOL surface, the patient achieved a best-corrected visual acuity of 20/20 without developing glaucoma or other complications. Therefore, Artisan IOL may be considered for correction of aphakia in patients with FHI. However, studies on large number of patients are required to evaluate safety of the procedure.

  8. Corneal thickness and daily curve of intraocular pressure in suspected and glaucomatous patients Espessura corneana e curva diária de pressão intra-ocular em pacientes suspeitos e glaucomatosos

    Directory of Open Access Journals (Sweden)

    Sebastião Cronemberger

    2005-04-01

    Full Text Available PURPOSE: To evaluate in suspected and glaucomatous patients the correlation between central corneal thickness (CCT and intraocular pressure (IOP, measured during the daily curve of intraocular pressure (DCPo, including CCT and IOP measurements in bed at 6 am. The ocular axial length was also compared. METHODS: 114 eyes from 73 patients, 30 eyes suspected of glaucoma (group I and 84 eyes with chronic open-angle glaucoma (group II were prospectively studied. Both groups were subjected to DCPo with measurements of IOP at 9 am, 12 pm, 6 pm, 10:30 pm and on the next day at 6 am in bed and in darkness before the patient gets up. Using the ultrasonic DGH 5100® device, CCT measurements were performed at 9 am, 6 pm, 10:30 pm and the next day at 6 am in bed before the patient gets up. The ocular axial length was also measured. RESULTS: In the total sample and, separately in each group, the mean IOP was more elevated in bed at 6 am. There were no significant CCT changes during the day within each group or between both groups. No statistically significant difference was found between the mean ocular axial length of both groups. CONCLUSIONS: In suspected and glaucomatous patients, there were no statistically significant CCT variations during the day; therefore, only one CCT measurement is sufficient. Also, there was no statistically significant difference between ocular axial length of both groups.OBJETIVO: Verificar em pacientes suspeitos de glaucoma e glaucomatosos se existe correlação entre a espessura corneana central (ECC e a pressão intra-ocular (Po, medidos durante a curva diária de pressão intra-ocular (CDPo, incluindo-se as medidas da ECC e da Po às 6:00 horas da manhã no leito. Avaliar também comparativamente o diâmetro axial ântero-posterior (Diâm. axial em ambos os grupos. MÉTODOS: 114 olhos de 73 pacientes selecionados no Serviço de Glaucoma do Hospital São Geraldo, foram divididos em dois grupos: grupo I - pacientes suspeitos de

  9. Artificial organisms that sleep.

    OpenAIRE

    Mirolli, Marco; Parisi, Domenico

    2003-01-01

    Abstract Populations of artificial organisms live in an environment in which light is cyclically present (day) or absent (night). Since being active during night is non-adaptive (activity consumes energy which is not compensated by the food found at night) the organisms evolve a sleep/wake behavioral pattern of being active during daytime and sleeping during nighttime. When the population moves to a different environment that contains "caves", they have to get out of a cave although the dark ...

  10. Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Kapil Nahar

    2012-12-01

    Full Text Available An artificial neural network is an information-processing paradigm that is inspired by the way biological nervous systems, such as the brain, process information. The key element of this paradigm is the novel structure of the information processing system. It is composed of a large number of highly interconnected processing elements (neurons working in unison to solve specific problems. Ann’s, like people, learn by example.

  11. Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Kapil Nahar

    2012-12-01

    Full Text Available An artificial neural network is an information-processing paradigm that is inspired by the way biological nervous systems, such as the brain, process information.The key element of this paradigm is the novel structure of the information processing system. It is composed of a large number of highly interconnected processing elements (neurons working in unison to solve specific problems.Ann’s, like people, learn by example.

  12. Artificial neural network modelling

    CERN Document Server

    Samarasinghe, Sandhya

    2016-01-01

    This book covers theoretical aspects as well as recent innovative applications of Artificial Neural networks (ANNs) in natural, environmental, biological, social, industrial and automated systems. It presents recent results of ANNs in modelling small, large and complex systems under three categories, namely, 1) Networks, Structure Optimisation, Robustness and Stochasticity 2) Advances in Modelling Biological and Environmental Systems and 3) Advances in Modelling Social and Economic Systems. The book aims at serving undergraduates, postgraduates and researchers in ANN computational modelling. .

  13. Artificial sweetener; Jinko kanmiryo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    The patents related to the artificial sweetener that it is introduced to the public in 3 years from 1996 until 1998 are 115 cases. The sugar quality which makes an oligosaccharide and sugar alcohol the subject is greatly over 28 cases of the non-sugar quality in the one by the kind as a general tendency of these patents at 73 cases in such cases as the Aspartame. The method of manufacture patent, which included new material around other peptides, the oligosaccharide and sugar alcohol isn`t inferior to 56 cases of the formation thing patent at 43 cases, and pays attention to the thing, which is many by the method of manufacture, formation. There is most improvement of the quality of sweetness with 31 cases in badness of the aftertaste which is characteristic of the artificial sweetener and so on, and much stability including the improvement in the flavor of food by the artificial sweetener, a long time and dissolution, fluid nature and productivity and improvement of the economy such as a cost are seen with effect on a purpose. (NEDO)

  14. Intraocular lens power calculation by measuring axial length with partial optical coherence and ultrasonic biometry

    OpenAIRE

    Beatriz Machado Fontes; Bruno Machado Fontes; Elaine Castro

    2011-01-01

    PURPOSE: To compare the achieved refractive outcomes of patients undergoing cataract surgery with intraocular lens (IOL) power calculation performed by conventional immersion ultrasound (US) or partial coherence interferometry (PCI). METHODS: Prospective, comparative case series. Patients undergoing cataract surgery were randomly divided in two groups with regard to the IOL power calculation method. Group 1 had calculations performed by PCI (IOL Master; Carl Zeiss Meditec), while US was used ...

  15. Intraocular Pressure in Eyes Receiving Intravitreal Antivascular Endothelial Growth Factor Injections

    OpenAIRE

    Lemos, V; Cabugueira, A; de Noronha, M; Abegão Pinto, L; Reina, M.; Branco, J; Gomes, T

    2015-01-01

    PURPOSE: The aim of the this study was to determine the effect of intravitreal antivascular endothelial growth factor injections on intraocular pressure (IOP) and identify possible risk factors for the development of increased IOP. MATERIALS AND METHODS: This prospective study included a total of 106 eyes receiving intravitreal injection of bevacizumab as treatment for macular edema or active choroidal neovascularization. IOP was measured by Goldmann applanation tonometry immediately be...

  16. [Iris suture fixation of posterior-chamber elastic intraocular lens in ligament apparatus laxity].

    Science.gov (United States)

    Pashtaev, N P; Bat'kov, E N; Zotov, V V

    2010-01-01

    An original MIOL-23 multifocal elastic intraocular lens (IOL) was used to operate 5 eyes with acquired lens dislocation and traumatic cataract. By making self-sealing tunnel incision, ILO was implanted into the capsular sac and sutured to the iris. MIOL-23 implantation caused an increase in mean visual acuity. The IOL took up a correct position. Elastic IOL implantation with iris suture fixation is an efficient and safe mode of additional ILO support. PMID:20645577

  17. Surgical management of spontaneous in-the-bag intraocular lens and capsular tension ring complex dislocation

    Directory of Open Access Journals (Sweden)

    Uzeyir Gunenc

    2014-01-01

    Full Text Available We describe a technique to manage late spontaneous intraocular lens (IOL and capsular tension ring (CTR dislocation within the intact capsular bag. The subluxated IOL and CTR complex can be positioned in a closed chamber and fixed to the pars plana at both 3 and 9 o′clock quadrants with the presented ab externo direct scleral suturation technique which provides an easy, safe and effective surgical option for such cases.

  18. Correlation of the intraocular pressure with increased intracranial pressure in rabbits

    Directory of Open Access Journals (Sweden)

    Eskandari H

    2000-08-01

    Full Text Available Although measurement of intracranial pressure by noninvasive methods has been suggested, but mainly invasive methods are used for this purpose-Increase in episcleral venous pressure can be expected to result in a linear increase in intraocular pressure. Congested oculat veins with capillary leakage and hemorrhage are seen when the ICP is increased, thus theoretically measurement of intraocular pressure can be a procedure for estimation of the ICP. This study was performed to find whether there is andy relationship between intraocular pressure and ICP, so we used 12 albino rabbits in two divided groups. Our study was not designed to elucidate the mechanism of change but merely to record any changes observed. All measures except an increase in ICP were applied on the test group as well as on the control group. After general anesthesia with the combination of ketamin, rampune, and pentobarbital a burr hole was made in the lambda region of the skull and a cannula was placed in the subdural space. The ICP in the test group increased up to 15 mmHg and was constant throughout the experiment. Intraocular pressure was measured by Schiotz tonometers afte general anesthesia, after cannulation of the skull, and immediately after increasing the ICP which was repated in 15 minutes interval for 4 hours. There was no statistical difference between the two groups (P:0.997 . results show that neither cannulation nor general anesthesia for 4 hours produce alteration in IOP in the control group nor increasing of the ICP to level of 15 mmHg produces any alteration in IOP on the test group.

  19. Treatment of dystrophic calcification on a silicone intraocular lens with pars plana vitrectomy

    OpenAIRE

    Mehta N; Goldberg RA; Shah CP

    2014-01-01

    Nitish Mehta,1 Roger A Goldberg,2 Chirag P Shah21University of Massachusetts Medical School, Worcester, MA, USA; 2Department of Retina, Ophthalmic Consultants of Boston, Boston, Massachusetts, USAPurpose: Dense, vision-obscuring calcification on the posterior aspect of silicone intraocular lenses (IOLs) is often not amenable to neodymium:yttrium-aluminum-garnet capsulotomy, and, in prior reports, has required IOL exchange. We report the successful removal of dense calcium deposition on the po...

  20. Scleral Fixation of Posteriorly Dislocated Intraocular Lenses by 23-Gauge Vitrectomy without Anterior Segment Approach

    OpenAIRE

    Jeroni Nadal; Bachar Kudsieh; Ricardo P. Casaroli-Marano

    2015-01-01

    Background. To evaluate visual outcomes, corneal changes, intraocular lens (IOL) stability, and complications after repositioning posteriorly dislocated IOLs and sulcus fixation with polyester sutures. Design. Prospective consecutive case series. Setting. Institut Universitari Barraquer. Participants. 25 eyes of 25 patients with posteriorly dislocated IOL. Methods. The patients underwent 23-gauge vitrectomy via the sulcus to rescue dislocated IOLs and fix them to the scleral wall with a ...

  1. Intraocular lens dislocation and tube shunt in the posterior chamber: a case report

    OpenAIRE

    Moreno-Montañés, Javier; Velázquez-Villoria, Alvaro; Sabater, Alfonso L.; Salinas-Alamán, Angel

    2015-01-01

    Background To describe management of a case of intraocular lens (IOL) and capsular bag (CB) dislocation in an eye with an Ahmed glaucoma valve in the posterior chamber. Case presentation A 75-year-old pseudophakic man with open-angle glaucoma and diabetic retinopathy developed neovascular glaucoma. After two intravitreous injections of bevacizumab and panretinal photocoagulation were administered, the new vessels regressed. However, goniosynechiae were observed over 360° of the angle. An Ahme...

  2. Risk Factors for Endophthalmitis and Retinal Detachment with Retained Intraocular Foreign Bodies

    OpenAIRE

    D. Wilkin Parke; Avinash Pathengay; Flynn, Harry W; Thomas Albini; Schwartz, Stephen G

    2012-01-01

    Purpose. To analyze risk factors for endophthalmitis and retinal detachment (RD) in patients with retained intraocular foreign bodies (IOFBs). Design. A retrospective, interventional, consecutive case series. Participants. All patients treated at Bascom Palmer Eye Institute for traumatic IOFBs between 1999 and 2008. Methods. Analysis of visual outcome, mechanism of injury, management, and postoperative course. Results. 108 eyes with IOFBs were identified. Endophthalmitis occurred in 7 eyes (...

  3. Risk Factors for Endophthalmitis and Retinal Detachment with Retained Intraocular Foreign Bodies

    OpenAIRE

    Parke, D. WilkinIII; Pathengay, Avinash; Flynn, Harry W.Jr.; Albini, Thomas; Schwartz, Stephen G

    2012-01-01

    Purpose. To analyze risk factors for endophthalmitis and retinal detachment (RD) in patients with retained intraocular foreign bodies (IOFBs). Design. A retrospective, interventional, consecutive case series. Participants. All patients treated at Bascom Palmer Eye Institute for traumatic IOFBs between 1999 and 2008. Methods. Analysis of visual outcome, mechanism of injury, management, and postoperative course. Results. 108 eyes with IOFBs were identified. Endophthalmitis occurred in 7 eyes (6...

  4. New Management of Angle-closure Glaucoma by Phacoemulsification with Foldable Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Jian Ge; Yan Guo; Yizhi Liu; Mingkai Lin; Yehong Zhuo; Bing Chen; Xiuqi Chen

    2000-01-01

    Objective: To investigate the management of angle-closure glaucoma by phacoemulsification with foldable posterior chamber intraocular lens (PC-IOL) implantation. Design: Retrospective, noncontrolled interventional case series.Participants: In 36 eyes with angle-closure glaucoma (ACG), there were 18 eyes with primary acute angle-closure glaucoma (PACG), 14 eyes with primary chronic angle-closure glaucoma (PCCG), 3 eyes with secondary acute angle-closure glaucoma (SACG) and 1 eye with secondary chronic angle-closure glaucoma (SCCG).Intervention: Phacoemulsification with posterior chamber intraocular lens implantation.Main Outcome Measures: Postoperative visual acuity, IOP, axial anterior chamber depth.Results: After a mean postoperative follow-up time of 8.81 ± 7.45 months, intraocular pressure was reduced from a preoperative mean of 23.81 ± 17.84 mmHg to a postoperative mean of 12.54 ± 4. 73 mmHg ( P = 0. 001 ). Mean anterior chamber depth was 1.75 ± 0.48 mm preoperatively and 2.29 ± 0.38 mm postoperatively ( P = 0. 000).Best spectacle-corrected visual acuity in 36 eyes ranged from 0. 01 to 0. 7 (20/200 to 20/30) postoperatively, which was better than preoperative VA ranging from hand movement to 0.4 (20/50) ( P= 0. 000).Conclusion: Phacoemulsification with posterior chamber foldable intraocular lens implantation can be a good alternative in treating angle-closure glaucoma. Eye Science 2000; 16:22 ~ 28.

  5. New Management of Angle-closure Glaucoma by Phacoemulsification with Folable Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    JianGE; YanGuo; 等

    2002-01-01

    Objective:To investigate the management of angle-closure glaucoma by phacoemulsification with foldable posterior chamber intraocular lens (PC-IOIL)implantation.Design:Retrospective,noncontrolled interventional case series.Participants:In 36 eyes with angle -closure glaucoma(ACG).there were 18eyes with primary acute angle-closure glaucoma(PACG),14 eyes with primary chonic angle -closure glaucoma(PCCG),3 eyes with secondary acute angle-closure glaucoma (SACG) and 1 eye with secondary chronic angle -closure glaucoma(SCCG).Intervention:Phacoemulsification with posterior chamber intraocular lens implantation.Main Outcome Measures:Postoperative visual acuity,IOP,axial anterior chamber depth.Results:After a mean postoperative follow -time of 8.81±7.45 months,intraocular pressure was reduced from a preoperative mean of 23.81±17.84 mmHg to a postoperative mean of 12.54±4.73mmHg(P=0.001).Mean anterior chamber depth was 1.75±0.48 mm preoiperatively and 2.29±0.38mm postoperatively(P-0.000).Best spectacle-corrected visual acuity in 36 eyes ranged from 0.01 to 0.7(20/200 to 20/30)postoperatively,which was better than preoperative VA ranging from hand movement to 0.4(20/50)(P=0.000).Conclusion:Phacoemulsification with posterior chamber foldable intraocular lens implantation can be a good alternative in treating angle-closure glaucoma.Eye Science2000;16:22-28.

  6. Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses

    OpenAIRE

    Nishi T.; Taketani F; Ueda T; Ogata N.

    2013-01-01

    Tomo Nishi, Futoshi Taketani, Tetsuo Ueda, Nahoko Ogata Department of Ophthalmology, Nara Medical University, Kashihara City, Nara, Japan Purpose: To determine the amplitude of pseudoaccommodation and higher-order aberrations with three types of implanted monofocal intraocular lenses (IOLs): aspheric yellow (IQ); spheric yellow (NT); and spheric clear (AT). Setting: Department of Ophthalmology, Nara Medical University, Nara, Japan. Methods: We studied 60 patients who underwent small incision...

  7. Use of hydroxypropylmethylcellulose 2% for removing adherent silicone oil from silicone intraocular lenses

    OpenAIRE

    Wong, S Chien; Ramkissoon, Yashin D; Lopez, Mauricio; Page, Kristopher; Ivan P. Parkin; Sullivan, Paul M

    2009-01-01

    Abstract Background / aims: To investigate the effect of hydroxypropylmethylcellulose (HPMC) on the physical interaction (contact angle) between silicone oil and a silicone intraocular lens (IOL). Methods: In vitro experiments were performed, to determine the effect of HPMC (0.5%, 1% or 2%), with or without an additional simple mechanical manoeuvre, on the contact angle of silicone oil at the surface of both silicone and acrylic (control) IOLs. A balanced salt solu...

  8. Effects of glaucoma medications on the cardiorespiratory and intraocular pressure status of newly diagnosed glaucoma patients

    OpenAIRE

    WALDOCK, A; Snape, J; Graham, C

    2000-01-01

    AIMS—To evaluate the short term cardiovascular, respiratory, and intraocular pressure (IOP) effects of four glaucoma medications in newly diagnosed glaucoma patients.
METHODS—141 newly diagnosed glaucoma patients were recruited and underwent a full ocular, cardiovascular, and respiratory examination, including an electrocardiogram (ECG) and spirometry. They were prescribed one of four topical glaucoma medications and reviewed 3 months later. One eye of each patient was randomly chosen for ana...

  9. Assessment of the central corneal thickness and intraocular pressure in premature and full-term newborns

    OpenAIRE

    Muslubas, Isil Bahar Sayman; Oral, Ayse Yesim Aydın; Cabi, Cemalettin; Caliskan, Sinan

    2014-01-01

    Purpose: To assess the central corneal thickness (CCT) and intraocular pressure (IOP) in premature and full-term newborns. Materials and Methods: In this study, we evaluated measurements of CCT and IOP in 45 premature and 45 full-term newborns. IOP was determined with topical anesthesia using a Tono-Pen AVIA, applanation tonometer and a wire lid retractor in premature newborns undergoing screening for retinopathy. Full-term newborns were used as a control group. CCT was determined with a port...

  10. Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible-Coiled LC Sensor Implant

    OpenAIRE

    Chen, Po-Jui; Saati, Saloomeh; Varma, Rohit; Humayun, Mark S.; Tai, Yu-Chong

    2010-01-01

    This paper presents an implant-based wireless pressure sensing paradigm for long-range continuous intraocular pressure (IOP) monitoring of glaucoma patients. An implantable parylene-based pressure sensor has been developed, featuring an electrical LC-tank resonant circuit for passive wireless sensing without power consumption on the implanted site. The sensor is microfabricated with the use of parylene C (poly-chlorop- xylylene) to create a flexible coil substrate that ca...

  11. The Impact of Multifocal Intraocular Lens in Retinal Imaging with Optical Coherence Tomography

    OpenAIRE

    Dias-Santos, A; Costa, L; Lemos, V; Anjos, R.; Vicente, A.(IFPA, Dep. AGO, Université de Liège, Bat B5, Sart-Tilman, B-4000, Liège 1, Belgium); Ferreira, J; Cunha, JP

    2015-01-01

    Multifocal intraocular lenses (MF IOLs) have concentric optical zones with different dioptric power, enabling patients to have good visual acuity at multiple focal points. However, several optical limitations have been attributed to this particular design. The purpose of this study is to access the effect of MF IOLs design on the accuracy of retinal optical coherence tomography (OCT). Cross-sectional study conducted at the Refractive Surgery Department of Central Lisbon Hospital Center. Twent...

  12. Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye

    OpenAIRE

    Fujikado, Takashi

    2014-01-01

    Takashi Fujikado,1 Makoto Saika2 1Department of Applied Visual Science, Osaka University Graduate School of Medicine, Osaka, Japan; 2Research and Development Department of Topcon Corporation, Tokyo, Japan Purpose: To examine the effect of misalignment (decentration and tilt) of intraocular lenses (IOLs) on retinal image quality using a water-immersed model eye with corneal spherical aberration adjusted to the values found in normal human eyes (spherical aberration 0.25 µm; pupil d...

  13. Comparison of retinal image quality with spherical and customized aspheric intraocular lenses

    OpenAIRE

    Guo, Huanqing; Goncharov, Alexander V.; Dainty, Chris

    2012-01-01

    We hypothesize that an intraocular lens (IOL) with higher-order aspheric surfaces customized for an individual eye provides improved retinal image quality, despite the misalignments that accompany cataract surgery. To test this hypothesis, ray-tracing eye models were used to investigate 10 designs of mono-focal single lens IOLs with rotationally symmetric spherical, aspheric, and customized surfaces. Retinal image quality of pseudo-phakic eyes using these IOLs together with individual variati...

  14. Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Tendal, Britta;

    2016-01-01

    TOPIC: We performed a systematic review and meta-analysis to evaluate the benefit and harms associated with implantation of toric intraocular lenses (IOLs) during cataract surgery. Outcomes were postoperative uncorrected distance visual acuity (UCDVA) and distance spectacle independence. Harms were...... evaluated as surgical complications and residual astigmatism. CLINICAL RELEVANCE: Postoperative astigmatism is an important cause of suboptimal UCDVA and need for distance spectacles. Toric IOLs may correct for preexisting corneal astigmatism at the time of surgery. METHODS: We performed a systematic...

  15. Intraocular pressure and influencing systemic health parameters in a Korean population

    OpenAIRE

    Young Sang Han; Ji Woong Lee; Jong Soo Lee

    2014-01-01

    Aim: To evaluate the relationship between intraocular pressure (IOP) and systemic health parameters such as age, gender, body mass index (BMI), total cholesterol, high density lipoprotein (HDL), and triglyceride (TG) in a Korean population. Materials and Methods: A total of 30,893 healthy subjects underwent automated multiphasic tests, including non-contact tonometry, automated perimetry, fundus photography, and blood samplings for total cholesterol, HDL, and TG. Seven age groups were divided...

  16. Evaluation of in vitro glistening formation in hydrophobic acrylic intraocular lenses

    OpenAIRE

    Thomes BE; Callaghan TA

    2013-01-01

    Brett E Thomes, Thomas A CallaghanAlcon Research Ltd (A Novartis Company), Fort Worth, TX, USAPurpose: To evaluate the impact of continuous manufacturing process improvements on glistening formation in AcrySof hydrophobic acrylic intraocular lenses (IOLs) by comparing lenses manufactured in 2003 with lenses manufactured in 2012.Methods: Glistenings were experimentally created as aqueous-filled microvacuoles utilizing an accelerated laboratory method by immersing the lens in water at 45&de...

  17. Toric intraocular lenses for correction of astigmatism in keratoconus and after corneal surgery

    OpenAIRE

    Mol, Ilse

    2016-01-01

    Ilse EMA Mol,1,2 Bart TH Van Dooren1,2 1Department of Ophthalmology, Amphia Hospital, Breda, 2Department of Ophthalmology, Erasmus Medical Center, Rotterdam, the Netherlands Purpose: To describe the results of cataract extraction with toric intraocular lens (IOL) implantation in patients with preexisting astigmatism from three corneal conditions (keratoconus, postkeratoplasty, and postpterygium surgery).Methods: Cataract patients with topographically stable, fairly regular (although sometim...

  18. Changes in intraocular pressures during laparoscopy: a comparison of propofol total intravenous anesthesia to desflurane-thiopental anesthesia.

    Science.gov (United States)

    Asuman, Arslan Onuk; Baris, Arslan; Bilge, Karsli; Bozkurt, Selen; Nurullah, Bülbüler; Meliha, Kahraman; Umit, Celik

    2013-02-01

    The aim of the study was to examine intraocular pressure (IOP) changes during laparoscopic cholecystectomy performed under either desflurane-thiopental anesthesia or propofol total intravenous anesthesia (TIVA). 36 patients who will undergo elective laparoscopic cholecystectomy were enrolled in the study. The patients were randomly divided into one of two groups: desflurane (Group D, n=18) or propofol (Group P, n=18). All patients received fentanyl 2 micro/kg IV, and then breathed 100% oxygen for 3 minutes prior to induction of anesthesia. Anesthesia was induced by using thiopental 5 mg/kg IV in Group D and 2 mg/kg IV propofol in group P. Neuromuscular block was achieved with rocuronium 0.6 mg/kg IV. Anesthesia was maintained with desflurane 3-6% in group D and propofol infusion 5-10 mg/kg/h in group P. Desflurane and propofol concentrations were adjusted to maintain mean arterial pressure witihin 20% of the preinduction value. During anaesthesia, fractionated doses of fentanyl 0.5-1 micro g /kg IV and maintenance doses of muscle relaxants were used. In both groups, the the mixture 60% nitrous oxide and 40% oxygen was administered used. Arterial pressure, heart rate, ETCO2, SpO2 and IOP were recorded at the predefined time points. Creation of pneumoperitoneum resulted in a significant increase in IOP which remained elevated throughout the operation in both groups. Also, we recorded a similar IOP changes with both techniques except at five minutes after pneumoperitoneum in 15 degrees reverse Trendelenburg position during desflurane-thiopental anesthesia. In c6nclusion, desflurane-thiopental anesthesia maintains the IOP at least at similar levels compared to propofol TIVA anesthesia.

  19. Clinical utility and differential effects of prostaglandin analogs in the management of raised intraocular pressure and ocular hypertension

    Directory of Open Access Journals (Sweden)

    Anne J Lee

    2010-07-01

    Full Text Available Anne J Lee1,2, Peter McCluskey2,31Manchester Royal Eye Hospital, Manchester, UK; 2University of Sydney, Sydney, Australia; 3Sydney Eye Hospital, Sydney, AustraliaAbstract: Prostaglandin analogs (PGA are powerful topical ocular hypotensive agents available for the treatment of elevated intraocular pressure (IOP. Latanoprost 0.005% and travoprost 0.004% are prodrugs and analogs of prostaglandin F2a. Bimatoprost 0.03% is regarded as a prostamide, and debate continues as to whether it is a prodrug. The free acids of all 3 PGAs reduce IOP by enhancing uveoscleral and trabecular outflow via direct effects on ciliary muscle relaxation and remodeling of extracellular matrix. The vast majority of clinical trials demonstrate IOP-lowering superiority of latanoprost, bimatoprost and travoprost compared with timolol 0.5%, brimonidine 0.2%, or dorzolamide 2% monotherapy. Bimatoprost appears to be more efficacious in IOP-lowering compared with latanoprost, with weighted mean difference in IOP reduction documented in one meta-analysis of 2.59% to 5.60% from 1- to 6-months study duration. PGAs reduce IOP further when used as adjunctive therapy. Fixed combinations of latanoprost, bimatoprost or travoprost formulated with timolol 0.5% and administered once daily are superior to monotherapy of its constituent parts. PGA have near absence of systemic side effects, although do have other commonly encountered ocular adverse effects. The adverse effects of PGA, and also those found more frequently with bimatoprost use include ocular hyperemia, eyelash growth, and peri-ocular pigmentary changes. Iris pigmentary change is unique to PGA treatment. Once daily administration and near absence of systemic side effects enhances tolerance and compliance. PGAs are often prescribed as first-line treatment for ocular hypertension and open-angle glaucoma.Keywords: prostaglandin analog, glaucoma, ocular hypertension, latanoprost, bimatoprost, travoprost

  20. Two cases of uveitis masquerade syndrome caused by bilateral intraocular large B-cell lymphoma

    Directory of Open Access Journals (Sweden)

    Jovanović Svetlana

    2013-01-01

    Full Text Available Introduction. Sometimes it is not easy to clinically recognize subtle differences between intraocular lymphoma and noninfectious uveitis. The most common lymphoma subtype involving the eye is B-cell lymphoma. Case report. We presented two patients aged 59 and 58 years with infiltration of the subretinal space with a large B-cell non-Hodgkin intraocular lymphoma. The patients originally had clinically masked syndrome in the form of intermediate uveitis. As it was a corticosteroid-resistant uveitis, we focused on the possible diagnosis of neoplastic causes of this syndrome. During hospitalization, the neurological symptoms emerged and multiple subretinal changes accompanied by yellowish white patches of retinal pigment epithelium with signs of vitritis, which made us suspect the intraocular lymphoma. Endocranial magnetic resonance imaging established tumorous infiltration in the region of the left hemisphere of the cerebellum. The histopathological finding confirmed the diagnosis of large B-cell non-Hodgkin lymphoma of risk moderate degree, immunoblast - centroblast cytological type. The other patient had clinical chronic uveitis accompanied by yellowish shaped white echographic changes of the retina and localized changes in the level of the subretina. The diagnosis of lymphoma was made by brain biopsy. Conclusion. Uveitis masquerade syndrome should be considered in all patients over 40 years with idiopathic steroid-resistant uveitis. Treatment begun on time can affect the course and improve the prognosis of uveitis masquerade syndrome (UMS and systemic disease.

  1. Successful Removal of Large Intraocular Foreign Body by 25-Gauge Microincision Vitrectomy Surgery

    Directory of Open Access Journals (Sweden)

    Hiroshi Kunikata

    2011-01-01

    Full Text Available We describe a new technique for removing a large intraocular foreign body by 25-gauge microincision vitrectomy surgery (25G-MIVS. Noncomparative interventional case series were performed at a single centre. Two patients with a long smooth intraocular vitreal foreign body underwent phacoemulsification and aspiration, intraocular lens implantation, 25G-MIVS, and extraction of the foreign body. The foreign body was removed through a posterior capsulorhexis, anterior continuous curvilinear capsulorhexis, and a corneal incision. In both cases, the foreign body was safely removed through the corneal incision, and IOL was implanted and well positioned. The surgical incision did not require suturing. No postoperative complications associated with this technique were found. The corneal endothelial cell density was maintained over 2000 cells/mm2 in both cases during recent follow-up examinations. Our findings indicate that 25G-MIVS with this technique can be used to extract a long slender smooth foreign body. It is safe, without complications, and can be performed without enlarging the 25-gauge sclerotomy.

  2. Acute Central Retinal Artery Occlusion Associated with Intraocular Silicone Oil Tamponade

    Directory of Open Access Journals (Sweden)

    Mehmet Yasin Teke

    2012-05-01

    Full Text Available Many systemic and ocular factors may cause acute central retinal artery occlusion (CRAO. Herein, we aimed to describe a case of CRAO due to intraocular silicone oil (SO tamponade. To the best of our knowledge, a case like our has not been reported previously. A 58-yearold male patient had undergone combined pars plana vitrectomy-lensectomy and intraocular SO for lens luxation and vitreus hemorrhage associated with a blunt ocular trauma in his right eye. Two weeks after the surgery, he presented with acute vision loss in the same eye. He was diagnosed with acute CRAO and it should be related with mechanical press or raised intraocular pressure (IOP associated with SO. He was treated by partial removal of SO immediately. In spite of the regression of retina edema, his visual acuity did not improve due to optic atrophy. SO may cause CRAO due to raised IOP and/or its mechanical pressure and this complication must be kept in mind. (Turk J Oph thal mol 2012; 42: 238-40

  3. Optical aberrations of intraocular lenses measured in vivo and in vitro

    Science.gov (United States)

    Barbero, Sergio; Marcos, Susana; Jiménez-Alfaro, Ignacio

    2003-10-01

    Corneal and ocular aberrations were measured in a group of eyes before and after cataract surgery with spherical intraocular lens (IOL) implantation by use of well-tested techniques developed in our laboratory. By subtraction of corneal from total aberration maps, we also estimated the optical quality of the intraocular lens in vivo. We found that aberrations in pseudophakic eyes are not significantly different from aberrations in eyes before cataract surgery or from previously reported aberrations in healthy eyes of the same age. However, aberrations in pseudophakic eyes are significantly higher than in young eyes. We found a slight increase of corneal aberrations after surgery. The aberrations of the IOL and the lack of balance of the corneal spherical aberrations by the spherical aberrations of the intraocular lens also degraded the optical quality in pseudophakic eyes. We also measured the aberrations of the IOL in vitro, using an eye cell model, and simulated the aberrations of the IOL on the basis of the IOL's physical parameters. We found a good agreement among in vivo, in vitro, and simulated measures of spherical aberration: Unlike the spherical aberration of the young crystalline lens, which tends to be negative, the spherical aberration of the IOL is positive and increases with lens power. Computer simulations and in vitro measurements show that tilts and decentrations might be contributors to the increased third-order aberrations in vivo in comparison with in vitro measurements.

  4. Stereoselectivity of satropane, a novel tropane analog, on iris muscarinic receptor activation and intraocular hypotension

    Institute of Scientific and Technical Information of China (English)

    Liang ZHU; Hong-zhuan CHEN; Li-min YANG; Yong-yao CUI; Pei-li ZHENG; Yin-yao NIU; Hao WANG; Yang LU; Qiu-shi REN; Pi-jing WEI

    2008-01-01

    Aim: To study the stereoselectivity of satropane (3-paramethylbenzene sulfonyloxy-6-acetoxy tropane), a novel tropane analog, on iris muscarinic receptor activation and intraocular hypotension. Methods: The assays for radioligand-receptor binding, the contractile responses of isolated iris muscle, the miosis response, and the intraocular hypotension of the enantiomers of satropane were investigated. Results: In the binding analysis, S(-)satropane (lesatropane) completely com-peted against the [3H]quinuclydinyl benzilate-labeled ligand at muscarinic recep-tors in the iris muscle, whereas R(+)satropane failed to completely compete. In an isolated iris contractile assay, R,S(±)satropane and S(-)satropane produced a concentration-dependent contractile response with similar efficacy and potency to that of carbachol. R(+)satropane did not induce any contractile response. In the pupil diameter measurement assay in vivo, S(-)satropane induced miosis much more effectively than pilocarpine, while R(+)satropane failed to produce any miosis. In the water loading-induced and methylcellulose-induced ocular hypertensive models, S(-)satropane, but not R(+)satropane, significantly suppressed intraocu-lar pressure at a much lower concentration than pilocarpine. Conclusion: The ago-nistic and hypotensive properties of satropane on rabbit eyes are stereoselective, with the S(-)isomer being its active form.

  5. Retropupillary Fixation of Iris-Claw Intraocular Lens for Aphakic Eyes in Children.

    Directory of Open Access Journals (Sweden)

    Martina Brandner

    Full Text Available To report outcome, complications and safety of retropupillary fixated iris-claw intraocular lenses in a pediatric population.Retrospective study.Ten consecutive pediatric patients (15 eyes underwent placement of retropupillary fixated iris-claw intraocular lenses between October 2007 and July 2013 at the Department of Ophthalmology, Medical University Graz and General Hospital Klagenfurt, Austria. Postoperative visual acuity and complications were analyzed.Median final best-corrected visual acuity improved by 0.12 logMAR from preoperative baseline. Mean postoperative spherical equivalent was -0.05 ± 1.76 D. No serious complications were observed intra- or postoperatively during the entire follow-up period of up to 40 months. One patient experienced a haptic disenclavation with IOL subluxation immediately after a car accident.Our study demonstrates that iris-claw intraocular lens implantation behind the iris is safe in children with lack of capsular support and yields excellent visual outcome with low complication rate.

  6. Artificial sweeteners--do they bear a carcinogenic risk?

    Science.gov (United States)

    Weihrauch, M R; Diehl, V

    2004-10-01

    Artificial sweeteners are added to a wide variety of food, drinks, drugs and hygiene products. Since their introduction, the mass media have reported about potential cancer risks, which has contributed to undermine the public's sense of security. It can be assumed that every citizen of Western countries uses artificial sweeteners, knowingly or not. A cancer-inducing activity of one of these substances would mean a health risk to an entire population. We performed several PubMed searches of the National Library of Medicine for articles in English about artificial sweeteners. These articles included 'first generation' sweeteners such as saccharin, cyclamate and aspartame, as well as 'new generation' sweeteners such as acesulfame-K, sucralose, alitame and neotame. Epidemiological studies in humans did not find the bladder cancer-inducing effects of saccharin and cyclamate that had been reported from animal studies in rats. Despite some rather unscientific assumptions, there is no evidence that aspartame is carcinogenic. Case-control studies showed an elevated relative risk of 1.3 for heavy artificial sweetener use (no specific substances specified) of >1.7 g/day. For new generation sweeteners, it is too early to establish any epidemiological evidence about possible carcinogenic risks. As many artificial sweeteners are combined in today's products, the carcinogenic risk of a single substance is difficult to assess. However, according to the current literature, the possible risk of artificial sweeteners to induce cancer seems to be negligible. PMID:15367404

  7. Effect of persistent high intraocular pressure on microstructure and hydraulic permeability of trabecular meshwork

    Science.gov (United States)

    Mei, Xi; Ren, Lin; Xu, Qiang; Zheng, Wei; Liu, Zhi-Cheng

    2015-05-01

    As the aqueous humor leaves the eye, it first passes through the trabecular meshwork (TM). Increased flow resistance in this region causes elevation of intraocular pressure (IOP), which leads to the occurrence of glaucoma. To quantitatively evaluate the effect of high IOP on the configuration and hydraulic permeability of the TM, second harmonic generation (SHG) microscopy was used to image the microstructures of the TM and adjacent tissues in control (normal) and high IOP conditions. Enucleated rabbit eyes were perfused at a pressure of 60 mmHg to achieve the high IOP. Through the anterior chamber of the eye, in situ images were obtained from different depths beneath the surface of the TM. Porosity and specific surface area of the TM in control and high IOP conditions were then calculated to estimate the effect of the high pressure on the permeability of tissue in different depths. We further photographed the histological sections of the TM and compared the in situ images. The following results were obtained in the control condition, where the region of depth was less than 55 μm with crossed branching beams and large pores in the superficial TM. The deeper meshwork is a silk-like tissue with abundant fluorescence separating the small size of pores. The total thickness of pathway tissues composed of TM and juxtacanalicular (JCT) is more than 100 μm. After putting a high pressure on the inner wall of the eye, the TM region progressively collapses and decreases to be less than 40 μm. Fibers of the TM became dense, and the porosity at 34 μm in the high IOP condition is comparable to that at 105 μm in the control condition. As a consequent result, the permeability of the superficial TM decreases rapidly from 120 μm2 to 49.6 μm2 and that of deeper TM decreases from 1.66 μm2 to 0.57 μm2. Heterogeneity reflected by descent in permeability reduces from 12.4 μm of the control condition to 3.74 μm of the high IOP condition. The persistently high IOP makes the TM

  8. Skuldertesten "Kombineret Elevation"

    DEFF Research Database (Denmark)

    Clausen, Mikkel Bek; Overkær, Brian

    2010-01-01

    Formål: At udarbejde en testprotokol for testen Kombineret Elevation (KE) og undersøge test-retest variationen ved test af elite svømmere, samt diskutere testens relevans og validitet. Materiale og Metode: 9 elite og 10 sub-elite svømmere, heraf var 11 mænd og 8 kvinder, gennemførte testen KE 2...

  9. The relationship between cytokine level and nitric oxide content in aqueous humor after intraocular lens implantation

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    AIM: To investigate the relationship between cytokine level and nitric oxide (NO) content in aqueous humor after intraocular lens implantation. METHODS: All New Zealand rabbits were divided randomly into three groups: (1) control group, (2) extracapsular cataract extraction group (ECCE), (3) extracapsular cataract extraction and posterior chamber intraocular lens implantation group (ECCE+IOL). The inflammation of all experimental rabbit eyes, including cornea edema and anterior chamber exudation were observed via zoom-photo slitlamp microscope 1,3,7,14,30 d postoperation. Meanwhile, aqueous humor was drawn for white blood cell (WBC) counting and classifying, and for NO-2/NO-3 and cytokine assay, including interleukin-2(IL-2), tumour necrosis factor-α(TNF-α). Statistics were taken by SPSS softwear. RESULTS: (1) Total WBC in aqueous humor were higher and anterior chamber exudation were more severe in ECCE+IOL group than that in ECCE group and control group. (2) The level of IL-2 and TNF-α and the content of NO-2/NO-3 in aqueous humor of ECCE+IOL group were higher than that in ECCE group and control group 1-14 d postoperation respectively, and it increased to peak value at 3-7 d postoperation and decreased gradually after two weeks postoperation. (3) The change regularity of IL-2, TNF-α and NO-2/NO-3 in each group were basically similar, i.e. when the level of cytokine (IL-2 and TNF-α) was normal, the content of NO-2/NO-3 was normal too, when the level of cytokine (IL-2 and TNF-α) increased, the content of NO-2/NO-3 increased too. CONCLUSION: The intraocular inflammation after ECCE+IOL was more severe than that after simple ECCE. NO, IL-2 and TNF-α play an important role in intraocular inflammation after intraocular lens implantation. The changes of IL-2 and TNF-α level was closely related with NO content in aqueous humor.

  10. Visual performance after the implantation of a new trifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Vryghem JC

    2013-10-01

    Full Text Available Jérôme C Vryghem,1,2 Steven Heireman1,21Brussels Eye Doctors, Brussels, Belgium; 2Clinique Saint-Jean, Brussels, BelgiumPurpose: To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens.Methods: A new trifocal diffractive intraocular lens was designed combining two superimposed diffractive profiles: one with +1.75 diopters (D addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that were operated on by one surgeon are included in this study. The uncorrected and best distance-corrected monocular and binocular, near, intermediate, and distance visual acuities, contrast sensitivity, and defocus curves were measured 6 months postoperatively. In addition to the standard clinical follow-up, a questionnaire evaluating individual satisfaction and quality of life was submitted to the patients.Results: The mean age of patients at the time of surgery was 70 ± 10 years. The mean uncorrected and corrected monocular distance visual acuity (VA were LogMAR 0.06 ± 0.10 and LogMAR 0.00 ± 0.08, respectively. The outcomes for the binocular uncorrected distance visual acuity were almost the same (LogMAR −0.04 ± 0.09. LogMAR −010 ± 0.15 and 0.02 ± 0.06 were measured for the binocular uncorrected intermediate and near VA, respectively. The distance-corrected visual acuity was maintained in mesopic conditions. The contrast sensitivity was similar to that obtained after implantation of a bifocal intraocular lens and did not decrease in mesopic conditions. The binocular defocus curve confirms good VA even in the intermediate distance range, with a moderate decrease of less than LogMAR 0.2 at −1.5 D, with respect to the best distance VA at 0 D defocus. Patient satisfaction was high. No discrepancy between the objective and subjective outcomes was evidenced.Conclusion: The introduction of a third focus in diffractive multifocal

  11. Prostaglandin E2-Glyceryl Ester: In Vivo Evidence for a Distinct Pharmacological Identity from Intraocular Pressure Studies.

    Science.gov (United States)

    Woodward, David F; Poloso, Neil J; Wang, Jenny W

    2016-08-01

    Prostaglandin E2 (PGE2)-2-glyceryl ester is a cyclo-oxygenase 2 product of the endocannabinoid 2-arachidonyl glycerol. It is claimed as pharmacologically novel, but this is complicated by rapid and irreversible isomerization to the 1(3) ester. For ocular studies, enzymatic hydrolysis of the ester moiety creates an additional complication. PG-glyceryl esters were stabilized to isomerization and hydrolysis by replacing the noncarbonyl O with NH, to form the serinolamide and propanediolamide as stable analogs of PG-2-glyceryl and PG-2-1(3) glyceryl esters, respectively. Intraocular pressure was measured in conscious dogs and conscious laser-induced ocular hypertensive monkeys. Pharmacological studies involved stable transfectants for each of the human recombinant prostanoid receptors and the isolated feline iris for prostamide activity. PGE2-serinolamide and PGE2- propanediolamide were essentially inactive at all receptors except the EP3 receptor (EC50, ∼500 nM). This obliged elucidation of EP3 receptor involvement in the intraocular pressure response to these PGE2-glycyerl ester analogs. Since the EP3 receptor agonists sulprostone and GR 63799 did not lower monkey intraocular pressure, a role for EP3 receptors in mediating the effects of PGE2-serinolamide and PGE2-propanediolamide is not indicated. PGE2-glyceryl ester (0.01% and 0.1%) substantially lowered intraocular pressure in monkeys. PGE2-propanediolamide was more efficacious than PGE2-serinolamide in lowering intraocular pressure in monkey eyes, but both appeared equieffective in dog eyes. PGE2-serinolamide dose-dependently (0.01- 0.1%) lowered intraocular pressure in both species, but PGF2 α-serinolamide was inactive. In conclusion, stable PGE2-glyceryl ester analogs lowered intraocular pressure. These findings are consistent with the presence of a PGE2-glyceryl ester-specific recognition site in the eye. PMID:27217589

  12. Mechanism of artificial heart

    CERN Document Server

    Yamane, Takashi

    2016-01-01

    This book first describes medical devices in relation to regenerative medicine before turning to a more specific topic: artificial heart technologies. Not only the pump mechanisms but also the bearing, motor mechanisms, and materials are described, including expert information. Design methods are described to enhance hemocompatibility: main concerns are reduction of blood cell damage and protein break, as well as prevention of blood clotting. Regulatory science from R&D to clinical trials is also discussed to verify the safety and efficacy of the devices.

  13. Polymer artificial muscles

    Directory of Open Access Journals (Sweden)

    Tissaphern Mirfakhrai

    2007-04-01

    Full Text Available The various types of natural muscle are incredible material systems that enable the production of large deformations by repetitive molecular motions. Polymer artificial muscle technologies are being developed that produce similar strains and higher stresses using electrostatic forces, electrostriction, ion insertion, and molecular conformational changes. Materials used include elastomers, conducting polymers, ionically conducting polymers, and carbon nanotubes. The mechanisms, performance, and remaining challenges associated with these technologies are described. Initial applications are being developed, but further work by the materials community should help make these technologies applicable in a wide range of devices where muscle-like motion is desirable.

  14. Uncertainty in artificial intelligence

    CERN Document Server

    Kanal, LN

    1986-01-01

    How to deal with uncertainty is a subject of much controversy in Artificial Intelligence. This volume brings together a wide range of perspectives on uncertainty, many of the contributors being the principal proponents in the controversy.Some of the notable issues which emerge from these papers revolve around an interval-based calculus of uncertainty, the Dempster-Shafer Theory, and probability as the best numeric model for uncertainty. There remain strong dissenting opinions not only about probability but even about the utility of any numeric method in this context.

  15. Bayesian artificial intelligence

    CERN Document Server

    Korb, Kevin B

    2010-01-01

    Updated and expanded, Bayesian Artificial Intelligence, Second Edition provides a practical and accessible introduction to the main concepts, foundation, and applications of Bayesian networks. It focuses on both the causal discovery of networks and Bayesian inference procedures. Adopting a causal interpretation of Bayesian networks, the authors discuss the use of Bayesian networks for causal modeling. They also draw on their own applied research to illustrate various applications of the technology.New to the Second EditionNew chapter on Bayesian network classifiersNew section on object-oriente

  16. Assessment of elevator rope using Hall Sensor

    International Nuclear Information System (INIS)

    Defect detection of wire rope for an elevator was investigated through the measurement of magnetic flux leakage. The types of defect usually found in wire rope categorized such as inner and outer wire breakage and wear. The specimens that has artificial defects were magnetized via permanent magnet, and measurement of magnetic flux leakage on the defects was performed with Hall sensor. In wire broken model, a defect smaller than 0.4 mm and 1 mm in depth on outer and inner wire rope, respectively, could be detected well. In wear model, smaller defect could not be detected clearly, however, appearance of changing of total magnetic flux during magnetic pole of the sensor passing through a defect 0.2 mm in depth at 4 mm or above width could make possible to detect it. From the results, the measurement via Hall sensor might be useful tool for defect detection of wire rope.

  17. Assesment of elevator rope using hall sensor

    International Nuclear Information System (INIS)

    Defect detection of wire rope for an elevator was investigated through the measurement of magnetic flux leakage. The types of defect usually found in wire rope categorized such as inner and outer wire breakage and wear. The specimens that has artificial defects were magnetized via permanent magnet, and measurement of magnetic flux leakage on the defects was performed with Hall sensor. In wire broken model, a defect smaller than 0.4mm and 1mm in depth on outer and inner wire rope, respectively, could be detected well. In wear model, smaller defect could not be detected clearly, however, appearance of changing of total magnetic flux during magnetic pole of the sensor passing through a defect 0.2mm in depth at 4mm or above width could make possible to detect it. From the results, the measurement via Hall sensor might be useful tool for defect detection of wire rope.

  18. How to teach artificial organs.

    Science.gov (United States)

    Zapanta, Conrad M; Borovetz, Harvey S; Lysaght, Michael J; Manning, Keefe B

    2011-01-01

    Artificial organs education is often an overlooked field for many bioengineering and biomedical engineering students. The purpose of this article is to describe three different approaches to teaching artificial organs. This article can serve as a reference for those who wish to offer a similar course at their own institutions or incorporate these ideas into existing courses. Artificial organ classes typically fulfill several ABET (Accreditation Board for Engineering and Technology) criteria, including those specific to bioengineering and biomedical engineering programs.

  19. Prótese intra-ocular de resina acrílica em cães e gatos Acrylic resin intraocular prosthesis in dogs and cats

    Directory of Open Access Journals (Sweden)

    S.C. Rahal

    2000-08-01

    Full Text Available Foram atendidos no Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Unesp - Campus de Botucatu, 11 animais (oito cães e três gatos, com alterações oftálmicas unilaterais graves que levaram à perda total da função ocular (protrusão de globo com injúria nervosa e estrutural, perfurações de córnea com perda de conteúdo intra-ocular e endoftalmites, entre outras. Os animais, com idades entre dois meses e 10 anos, foram submetidos à evisceração e posterior inclusão de esfera de resina acrílica (metilmetacrilato na capa córneo-escleral ou escleral. As esferas foram previamente confeccionadas e esterilizadas por autoclavagem. No pós-operatório foram utilizados antiinflamatórios e antibioticoterapia tópica combinada ou não a sistêmica. O período de observação variou de 2 meses a 3 anos e os aspectos avaliados foram secreção ocular, blefarospasmo, sinais de desconforto e estética. Obtiveram-se resultados satisfatórios em oito casos. Concluiu-se que a resina acrílica pode ser uma alternativa para uso como inclusão em cavidade anoftálmica.Eleven animals (eight dogs and three cats, aged between two months and ten years were referred to the Veterinary Hospital of Faculty of Veterinary Medicine and Animal Science - Unesp, Botucatu, Brazil. These animals presented severe unilateral ophthalmic changes that lead to a total loss of ocular function, such as prolapsed eyes with nervous and structural injury, corneal damage with loss of intraocular contents or endophthalmitis among others. They were submitted to evisceration followed by the insertion of an acrylic resin prosthesis (methylmethacrylate in the corneoscleral or scleral shell. The spheres were previously made and sterilized by autoclave. The postoperative medical therapy included topical and systemic broad-spectrum antibiotics for seven days and anti-inflammatory drugs. The follow-up time varied from two months to three years. The evaluated

  20. Development of artificial empathy.

    Science.gov (United States)

    Asada, Minoru

    2015-01-01

    We have been advocating cognitive developmental robotics to obtain new insight into the development of human cognitive functions by utilizing synthetic and constructive approaches. Among the different emotional functions, empathy is difficult to model, but essential for robots to be social agents in our society. In my previous review on artificial empathy (Asada, 2014b), I proposed a conceptual model for empathy development beginning with emotional contagion to envy/schadenfreude along with self/other differentiation. In this article, the focus is on two aspects of this developmental process, emotional contagion in relation to motor mimicry, and cognitive/affective aspects of the empathy. It begins with a summary of the previous review (Asada, 2014b) and an introduction to affective developmental robotics as a part of cognitive developmental robotics focusing on the affective aspects. This is followed by a review and discussion on several approaches for two focused aspects of affective developmental robotics. Finally, future issues involved in the development of a more authentic form of artificial empathy are discussed.

  1. Generative Artificial Intelligence : Philosophy and Theory of Artificial Intelligence

    NARCIS (Netherlands)

    van der Zant, Tijn; Kouw, Matthijs; Schomaker, Lambertus; Mueller, Vincent C.

    2013-01-01

    The closed systems of contemporary Artificial Intelligence do not seem to lead to intelligent machines in the near future. What is needed are open-ended systems with non-linear properties in order to create interesting properties for the scaffolding of an artificial mind. Using post-structuralistic

  2. Specific features of measuring the optical power of artificial refractive and diffractive-refractive eye lenses

    Science.gov (United States)

    Lenkova, G. A.

    2016-08-01

    Methods for monitoring the optical power of artificial refractive eye lenses (intraocular lenses) based on measuring focal lengths in air and in medium are analyzed. The methods for determining the refraction of diffractive-refractive lenses (in particular, of MIOL-Akkord type), with allowance for the specific features of the diffractive structure, are considered. A computer simulation of the measurement of the focal length of MIOL-Akkord lenses is performed. The effective optical power of the diffractive component of these lenses is shown to depend on the diaphragm diameter. The optimal diaphragm diameter, at which spherical aberrations do not affect the position of foci, is found to be 3 mm. Possible errors in measuring the focal lengths are analyzed, and the necessary corrections that must be introduced into measurement results and calculations of refractions are determined.

  3. Aderência bacteriana in vitro a lentes intra-oculares de polimetilmetacrilato e de silicone In vitro bacterial adherence to silicone and polymetylmethacrylate intraocular lenses

    Directory of Open Access Journals (Sweden)

    Claudete Inês Locatelli

    2004-04-01

    Full Text Available OBJETIVOS: Verificar a aderência bacteriana a lentes intra-oculares de silicone e de polimetilmetacrilato como possível fator de risco no desenvolvimento de endoftalmite pós-operatória, utilizando-se um modelo in vitro com três microrganismos potencialmente patogênicos. MÉTODOS: As análises foram realizadas com cepas de Staphylococcus aureus ATCC 29213, Staphylococcus epidermidis (amostra clínica e Pseudomonas aeruginosa ATCC 27853 incluindo a determinação de curvas de crescimento, testes para verificação de produção de cápsula, avaliação da hidrofobicidade, testes de aderência a diferentes materiais, microscopia óptica, microscopia eletrônica de varredura e microscopia de força atômica. RESULTADOS: A produção de cápsula e a aderência das três diferentes cepas não mostraram qualquer relação com a quantidade de microrganismos; em relação às lentes intra-oculares de polimetilmetacrilato e de silicone, não houve diferença estatisticamente significativa na aderência de S. aureus e S. epidermidis; P. aeruginosa foi o microrganismo mais aderente a ambos os materiais. A microscopia eletrônica de varredura confirmou estes achados em relação à aderência, ao peso que a microscopia de força atômica evidenciou a produção de biofilme pelas cepas de S. aureus, S. epidermidis e P. aeruginosa. CONCLUSÕES: Constatou-se, in vitro, que os materiais analisados não diferiram com relação à taxa de aderência bacteriana, porém, P. aeruginosa apresentou maior eficiência de adesão entre as bactérias testadas. Todas as cepas produziram biofilme. Silicone foi o material mais hidrofóbico, quando comparado ao polimetilmetacrilato.PURPOSE: To evaluate bacterial adherence to silicone and polymetylmethacrylate (PMMA intraocular lenses as a risk factor for postsurgery endophthalmitis by using an in vitro model with three potentially pathogenic microorganisms. METHODS: In vitro experiments were carried out with the

  4. Artificial organs: recent progress in artificial hearing and vision.

    Science.gov (United States)

    Ifukube, Tohru

    2009-01-01

    Artificial sensory organs are a prosthetic means of sending visual or auditory information to the brain by electrical stimulation of the optic or auditory nerves to assist visually impaired or hearing-impaired people. However, clinical application of artificial sensory organs, except for cochlear implants, is still a trial-and-error process. This is because how and where the information transmitted to the brain is processed is still unknown, and also because changes in brain function (plasticity) remain unknown, even though brain plasticity plays an important role in meaningful interpretation of new sensory stimuli. This article discusses some basic unresolved issues and potential solutions in the development of artificial sensory organs such as cochlear implants, brainstem implants, artificial vision, and artificial retinas. PMID:19330498

  5. A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery

    OpenAIRE

    Bikramjit Das; Rajiv Kumar Samal; Arup Ghosh; Ratul Kundu

    2016-01-01

    BACKGROUND: We compared intraocular pressure changes following laryngoscopy and intubation with conventional Macintosh blade and Airtraq optical laryngoscope. METHODS: Ninety adult patients were randomly assigned to study group or control group. Study group (n = 45) - Airtraq laryngoscope was used for laryngoscopy. Control group (n = 45) - conventional Macintosh laryngoscope was used for laryngoscopy. Preoperative baseline intraocular pressure was measured with Schiotz tonometer. Laryngosc...

  6. Artificial sweeteners - a review.

    Science.gov (United States)

    Chattopadhyay, Sanchari; Raychaudhuri, Utpal; Chakraborty, Runu

    2014-04-01

    Now a days sugar free food are very much popular because of their less calorie content. So food industry uses various artificial sweeteners which are low in calorie content instead of high calorie sugar. U.S. Food and Drug Administration has approved aspartame, acesulfame-k, neotame, cyclamate and alitame for use as per acceptable daily intake (ADI) value. But till date, breakdown products of these sweeteners have controversial health and metabolic effects. On the other hand, rare sugars are monosaccharides and have no known health effects because it does not metabolize in our body, but shows same sweet taste and bulk property as sugar. Rare sugars have no such ADI value and are mainly produced by using bioreactor and so inspite of high demand, rare sugars cannot be produced in the desired quantities. PMID:24741154

  7. Artificial Immune Systems (2010)

    CERN Document Server

    Greensmith, Julie; Aickelin, Uwe

    2010-01-01

    The human immune system has numerous properties that make it ripe for exploitation in the computational domain, such as robustness and fault tolerance, and many different algorithms, collectively termed Artificial Immune Systems (AIS), have been inspired by it. Two generations of AIS are currently in use, with the first generation relying on simplified immune models and the second generation utilising interdisciplinary collaboration to develop a deeper understanding of the immune system and hence produce more complex models. Both generations of algorithms have been successfully applied to a variety of problems, including anomaly detection, pattern recognition, optimisation and robotics. In this chapter an overview of AIS is presented, its evolution is discussed, and it is shown that the diversification of the field is linked to the diversity of the immune system itself, leading to a number of algorithms as opposed to one archetypal system. Two case studies are also presented to help provide insight into the m...

  8. Artificial Enzymes, "Chemzymes"

    DEFF Research Database (Denmark)

    Bjerre, Jeannette; Rousseau, Cyril Andre Raphaël; Pedersen, Lavinia Georgeta M;

    2008-01-01

    "Chemzymes", based on cyclodextrins and other molecules. Only the chemzymes that have shown enzyme-like activity that has been quantified by different methods will be mentioned. This review will summarize the work done in the field of artificial glycosidases, oxidases, epoxidases, and esterases, as well...... as chemzymes that catalyze conjugate additions, cycloadditions, and self-replicating processes. The focus will be mainly on cyclodextrin-based chemzymes since they have shown to be good candidate structures to base an enzyme model skeleton on. In addition hereto, other molecules that encompass binding......Enzymes have fascinated scientists since their discovery and, over some decades, one aim in organic chemistry has been the creation of molecules that mimic the active sites of enzymes and promote catalysis. Nevertheless, even today, there are relatively few examples of enzyme models...

  9. Elevated temperature crack growth

    Science.gov (United States)

    Kim, K. S.; Vanstone, R. H.

    1992-01-01

    The purpose of this program was to extend the work performed in the base program (CR 182247) into the regime of time-dependent crack growth under isothermal and thermal mechanical fatigue (TMF) loading, where creep deformation also influences the crack growth behavior. The investigation was performed in a two-year, six-task, combined experimental and analytical program. The path-independent integrals for application to time-dependent crack growth were critically reviewed. The crack growth was simulated using a finite element method. The path-independent integrals were computed from the results of finite-element analyses. The ability of these integrals to correlate experimental crack growth data were evaluated under various loading and temperature conditions. The results indicate that some of these integrals are viable parameters for crack growth prediction at elevated temperatures.

  10. Instructional Applications of Artificial Intelligence.

    Science.gov (United States)

    Halff, Henry M.

    1986-01-01

    Surveys artificial intelligence and the development of computer-based tutors and speculates on the future of artificial intelligence in education. Includes discussion of the definitions of knowledge, expert systems (computer systems that solve tough technical problems), intelligent tutoring systems (ITS), and specific ITSs such as GUIDON, MYCIN,…

  11. Sucrose compared with artificial sweeteners

    DEFF Research Database (Denmark)

    Sørensen, Lone Brinkmann; Vasilaras, Tatjana H; Astrup, Arne;

    2014-01-01

    There is a lack of appetite studies in free-living subjects supplying the habitual diet with either sucrose or artificially sweetened beverages and foods. Furthermore, the focus of artificial sweeteners has only been on the energy intake (EI) side of the energy-balance equation. The data are from...

  12. Artificial Ligaments: Promise or Panacea?

    Science.gov (United States)

    Lubell, Adele

    1987-01-01

    The Food and Drug Administration has approved a prosthetic ligament for limited use in persons with damaged anterior cruciate ligaments (ACL). This article addresses ligament repair, ACL tears, current treatment, development of the Gore-Tex artificial ligament, other artificial ligaments in process, and arguments for and against their use.…

  13. Iris Claw versus Scleral Fixation Intraocular Lens Implantation during Pars Plana Vitrectomy

    Directory of Open Access Journals (Sweden)

    Fereydoun Farrahi

    2012-01-01

    Full Text Available Purpose: To compare the outcomes of iris claw anterior chamber intraocular lens (ICACIOL with that of scleral fixation posterior chamber intraocular lens (SF-PCIOL implantation during pars plana vitrectomy (PPV as initial surgery to correct aphakia. Methods: Twelve patients with complicated cataract surgery or trauma who had suffered nucleus, whole crystalline lens or intraocular lens (IOL drop into the vitreous cavity, and undergone PPV with IC-ACIOL implantation over a period of one year were evaluated for the purpose of this study. Uncorrected visual acuity (UCVA, best corrected visual acuity (BCVA, central corneal thickness (CCT, spherical equivalent (SE refractive error, astigmatism and complications were recorded. The results were compared to outcomes of another group of 13 patients who had previously undergone PPV with SF-PCIOL implantation. Results: Mean improvement of UCVA was greater in IC-ACIOL eyes as compared to the SF-PCIOL group (-1.17±0.28 versus -0.89±0.21 logMAR, P=0.01, corresponding values for postoperative BCVA were 0.24±0.17 and 0.44±0.22 logMAR (P=0.041, respectively. Average postoperative SE was comparable in the IC-ACIOL and SFPCIOL groups at 0.6±1.03 and 0.56±1.23 diopters, respectively (P=0.290. However, 10 (83.3% IC-ACIOL eyes versus 6 (46.1% SF-PCIOL eyes had SE within 1 diopter of emmetropia (P=0.048. Mean postoperative increase in CCT was comaparble between the study groups (P=0.126. Conclusion: In the absence of sufficient capsular support, the use of an IC-ACIOL for correction of aphakia during PPV can be a good alternative and seems to entail better visual outcomes as compared to SF-PCIOL.

  14. Densiron® 68 as an intraocular tamponade for complex inferior retinal detachments

    Directory of Open Access Journals (Sweden)

    Hussain RN

    2011-05-01

    Full Text Available Rumana N Hussain, Somnath BanerjeeLeicester Royal Infirmary, Leicester, UKIntroduction: Densiron® 68 is a high-density liquid used to tamponade inferior retinal detachments. We present a case series of 12 patients treated with Densiron as an intraocular tamponade agent.Methods: A retrospective analysis of 12 eyes in 12 patients was carried out. The primary endpoint was anatomic reattachment of the retina following removal of Densiron oil.Results: All patients had inferior detachments; 33% had associated proliferative vitreoretinopathy (PVR. Densiron was utilized as a primary agent in five patients (42%; the remaining patients had prior unsuccessful surgery for retinal reattachment, including pars plana vitrectomy, cryotherapy, laser, encirclement, gas (C3F8 or C2F6, or silicone oil. Eleven patients (91% had successful reattachment of the retina at 3 months following removal of Densiron; one patient had extensive PVR, total retinal detachment, preretinal macula fibrosis, and chronic hypotony, and surgical intervention was unsuccessful. Six patients (50% had raised intraocular pressure (IOP, resolving in the majority of cases following Densiron removal; two patients had long-term raised IOP requiring topical or surgical therapy. Of the six phakic patients, 50% developed significant cataract in the operated eye. Of those with successful retinal reattachment, visual outcome was variable, with 36% patients gaining two to four lines on Snellen, 27% remaining objectively the same, and 36% losing one to two lines.Conclusion: The anatomic success rate is high (91% in patients requiring Densiron tamponade for inferior retinal detachments with or without evidence of PVR either as a primary or secondary intervention. A common complication is raised IOP; however, this most often resolves following removal of the oil.Keywords: intraocular tamponade, silicone oil, retinal detachment, retinal reattachments

  15. Treatment of cytomegalovirus retinitis with an intraocular sustained-release ganciclovir implant

    Directory of Open Access Journals (Sweden)

    Muccioli C.

    2000-01-01

    Full Text Available The objective of this prospective study was to evaluate the efficacy and complications of the use of an intraocular sustained-release ganciclovir implant for the treatment of active cytomegalovirus (CMV retinitis in AIDS patients. Thirty-nine eyes of 26 patients were submitted to ocular surgery. All patients underwent complete ocular examination before and after surgery. The surgical procedure was always done under local anesthesia using the same technique. The mean time for the surgical procedure was 20 min (range, 15 to 30 min. The average follow-up period was 3.7 months. Of all patient, only 4 presented recurrence of retinitis after 8, 8, 9 and 2 months, respectively. Three of them received a successful second implant. All 39 eyes of the 26 patients presented healing of retinitis as shown by clinical improvement evaluated by indirect binocular ophthalmoscopy and retinography. Retinitis healed within a period of 4 to 6 weeks in all patients, with clinical regression signs from the third week on. Six (15.4% eyes developed retinal detachment. None of the patients developed CMV retinitis in the contralateral eye. The intraocular implant proved to be effective in controlling the progression of retinitis for a period of up to 8 months even in patients for whom systemic therapy with either ganciclovir or foscarnet or both had failed. The intraocular sustained-release ganciclovir implant proved to be a safe new procedure for the treatment of CMV retinitis, avoiding the systemic side effects caused by the intravenous medications and improving the quality of life of the patients.

  16. Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

    Directory of Open Access Journals (Sweden)

    Mi Tian

    Full Text Available To evaluate intra- and intersession repeatability of objective optical quality and intraocular scattering measurements with a double-pass system in children.Forty-two eyes of 42 children were included in the study. An optical quality analysis system (OQAS was used to measure optical quality parameters, including modulation transfer function cutoff frequency (MTFcutoff, Strehl ratio (SR, OQAS values (OV at 3 different contrasts and objective scatter index (OSI. Three measurement sessions with 10-min intervals were operated by the same technician, and in each session four consecutive measurements were obtained.Mean values for MTFcutoff, SR and OSI were 46.85 ± 7.45cpd, 0.27 ± 0.06 and 0.34 ± 0.22 respectively. 1 The intraclass correlation coefficients were ranged from 0.89 to 0.97 and coefficients of variation from 0.06 to 0.16 for all the parameters in the first session; the relative repeatability were 11.1% (MTFcutoff, 22.5% (SR, 10.9% (OV100%, 16.6% (OV2%, 22.4% (OV9% and 56.3% (OSI. Similar results were found in the second and third sessions. 2 Bland-Altman analysis showed that narrow 95% confidence intervals (compared between the first and second sessions ranged from -5.42 to 5.28 (MTFcutoff, -0.05 to 0.07 (SR, -0.18 to 0.18 (OV100%, -0.26 to 0.29 (OV20%, -0.33 to 0.39 (OV9% and -0.11 to 0.09 (OSI; the comparison between any two of the three sessions showed similar results.Measurements of optical quality and intraocular scattering in children by the double-pass system showed good intra- and intersession repeatability. Retinal image quality is high and intraocular scattering is low in children.

  17. Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses

    Directory of Open Access Journals (Sweden)

    Gibbons A

    2016-10-01

    Full Text Available Allister Gibbons, Tayyeba K Ali, Daniel P Waren, Kendall E Donaldson Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA Purpose: The purpose of this study was to assess the causes and possible solutions for patient dissatisfaction after the implantation of presbyopia-correcting intraocular lenses (IOLs. Methods: This study was a retrospective review of clinical records. All patients who were seen between January 2009 and December 2013 whose primary reason for consultation was dissatisfaction with visual performance after presbyopia-correcting IOL implantation were included in the study. A single treating physician, who determined the most probable cause of dissatisfaction, decided which interventions to pursue following the initial consultation. Results: Data from 74 eyes of 49 patients were analyzed. The most common cause for complaint was blurry or foggy vision both for distance and near (68%. Complaints were most frequently attributed to residual refractive error (57% and dry eye (35%. The most common interventions pursued were treatment of refractive error with glasses or contact lenses (46% and treatment for dry eye (24%. Corneal laser vision correction was done in 8% of eyes; 7% required an IOL exchange. After the interventions, 45% of patients had completed resolution of symptoms, 23% of patients were partially satisfied with the results, and 32% remained completely dissatisfied with the final results. Conclusion: The most identifiable causes of dissatisfaction after presbyopia-correcting IOL implantation are residual refractive error and dry eye. Most patients can be managed with conservative treatment, though a significant number of patients remained unsatisfied despite multiple measures. Keywords: intraocular lens, cataract, presbyopia, multifocal intraocular lens

  18. Toric markers-assisted implantation of the scleral-fixated intraocular lens

    Science.gov (United States)

    Song, Hu-Ping; Tian, Bing-Yu; Peng, Jing

    2016-01-01

    AIM To evaluate the efficacy of toric intraocular lens markers-assisted implantation of the scleral-fixated intraocular lens (SFIOL). METHODS From October 2010 to December 2013, all patients who had undergone secondary SFIOL implantation were assigned to group 1 and 2, in group 1 SFIOL was performed with the assist of radial keratotomy (RK)-marker, and in group 2 SFIOL was performed with the assisted of toric intraocular lens markers (T-and axis markers). Patients' demographic data and information on baseline preoperative visual acuity, indication for surgery and latest postoperative visual acuity were collected and analyzed. The haptic and optic positions were determined by ultrasound biomicroscopy. The optic tilt angle and decentration distance were measured. RESULTS The study evaluated 43 eyes of 43 patients ranging in age from 3 to 66y. Group 1 comprised 24 eyes (24 patients) and group 2, 19 eyes (19 patients). Uncorrected reoperative acuity was improved on all the eyes postoperatively. The improved postoperative acuity was significantly more in group 2 than that in group 1 (1.11±0.38 vs 0.82±0.45 logMAR; F=4.85, P=0.03). Ultrasonic biomicrograph examination showed that the rate of haptic asymmetry was significantly higher in group 1 (42%, 10/24) than that in group 2 (11%; 2/19) (Chi square=3.68, P=0.04). The mean tilted degree in group 1 was significantly higher than that in group 2 (P=0.04). Mean decentration distance in group 1 was greater than that in group 2 (P=0.03). CONCLUSION During SFIOL the toric markers help the surgeon identify the placement of fixation more precisely than that with the use of RK marker. PMID:27672593

  19. Environmental and health impacts of artificial turf: a review.

    Science.gov (United States)

    Cheng, Hefa; Hu, Yuanan; Reinhard, Martin

    2014-02-18

    With significant water savings and low maintenance requirements, artificial turf is increasingly promoted as a replacement for natural grass on athletic fields and lawns. However, there remains the question of whether it is an environmentally friendly alternative to natural grass. The major concerns stem from the infill material that is typically derived from scrap tires. Tire rubber crumb contains a range of organic contaminants and heavy metals that can volatilize into the air and/or leach into the percolating rainwater, thereby posing a potential risk to the environment and human health. A limited number of studies have shown that the concentrations of volatile and semivolatile organic compounds in the air above artificial turf fields were typically not higher than the local background, while the concentrations of heavy metals and organic contaminants in the field drainages were generally below the respective regulatory limits. Health risk assessment studies suggested that users of artificial turf fields, even professional athletes, were not exposed to elevated risks. Preliminary life cycle assessment suggested that the environmental impacts of artificial turf fields were lower than equivalent grass fields. Areas that need further research to better understand and mitigate the potential negative environmental impacts of artificial turf are identified. PMID:24467230

  20. Soft computing in artificial intelligence

    CERN Document Server

    Matson, Eric

    2014-01-01

    This book explores the concept of artificial intelligence based on knowledge-based algorithms. Given the current hardware and software technologies and artificial intelligence theories, we can think of how efficient to provide a solution, how best to implement a model and how successful to achieve it. This edition provides readers with the most recent progress and novel solutions in artificial intelligence. This book aims at presenting the research results and solutions of applications in relevance with artificial intelligence technologies. We propose to researchers and practitioners some methods to advance the intelligent systems and apply artificial intelligence to specific or general purpose. This book consists of 13 contributions that feature fuzzy (r, s)-minimal pre- and β-open sets, handling big coocurrence matrices, Xie-Beni-type fuzzy cluster validation, fuzzy c-regression models, combination of genetic algorithm and ant colony optimization, building expert system, fuzzy logic and neural network, ind...

  1. Beyond AI: Artificial Dreams Conference

    CERN Document Server

    Zackova, Eva; Kelemen, Jozef; Beyond Artificial Intelligence : The Disappearing Human-Machine Divide

    2015-01-01

    This book is an edited collection of chapters based on the papers presented at the conference “Beyond AI: Artificial Dreams” held in Pilsen in November 2012. The aim of the conference was to question deep-rooted ideas of artificial intelligence and cast critical reflection on methods standing at its foundations.  Artificial Dreams epitomize our controversial quest for non-biological intelligence, and therefore the contributors of this book tried to fully exploit such a controversy in their respective chapters, which resulted in an interdisciplinary dialogue between experts from engineering, natural sciences and humanities.   While pursuing the Artificial Dreams, it has become clear that it is still more and more difficult to draw a clear divide between human and machine. And therefore this book tries to portrait such an image of what lies beyond artificial intelligence: we can see the disappearing human-machine divide, a very important phenomenon of nowadays technological society, the phenomenon which i...

  2. Intra-operative assessment of toric intra-ocular lens implantation

    Directory of Open Access Journals (Sweden)

    Tsinopoulos Ioannis

    2011-01-01

    Full Text Available We report a new procedure for intra-operative toric intra-ocular lens (IOL axis assessment in order to achieve optimal implantation. IOL implantation procedure was directly recorded. An assessor estimated the angle formed by the marked 0-180 axis and the toric IOL axis after implantation with the use of the appropriate software. If IOL implantation was assessed to be inaccurate, the surgeon was advised to correct IOL positioning by rotating the IOL clockwise. The assessment procedure was repeated until accurate IOL positioning was achieved.

  3. A slide rule for calculating the power of an intraocular lens.

    Science.gov (United States)

    Wang, G J; Pomerantzeff, O; Miao, T Y

    1983-01-01

    We have designed a slide rule to calculate the emmetropizing and iseikonizing power of an intraocular lens (IOL). Like the dial biometer currently used for these calculations, the slide rule is inexpensive, easy to use, simple, and a compact pocket size. It can, however, also be used to calculate postoperative refractive error, corneal power when various keratometers are used, and conversion of refractive correction at the spectacle frame to that at the cornea, or vice versa. All the calculated data are within the accuracy suitable for clinical work. PMID:6630016

  4. Innovative confocal laser method for exact dioptric power measurement of intraocular lens implants Invited Paper

    Institute of Scientific and Technical Information of China (English)

    Ilko K. Ilev; Robert W. Faaland; Do-Hyun Kim; Robert H. James; Don Calogero

    2008-01-01

    We present a novel confocal laser method (CLM) for precise testing of the dioptric power of both positive and negative intraocular lens (IOL) implants. The CLM principle is based on a simple fiber-optic confocal laser design including a single-mode fiber coupler that serves simultaneously as a point light source used for formation of a collimated Gaussian laser beam, and as a highly sensitive confocal point receiver. The CLM approach provides an accurate, repeatable, objective, and fast method for IOL dioptric power measurement over the range from 0 D to greater than =t=30 D under both dry and in-situ simulated conditions.

  5. Pars plana cicatrization of sewn-in posterior chamber intraocular lens haptics.

    Science.gov (United States)

    McDermott, M L; Puklin, J E

    1997-03-01

    The authors describe the unexpected finding of cicatrization of posterior chamber lens haptics to the pars plana. This was found during removal of a secondary, transscleral sewn-in pseudophakos during a retinal reattachment procedure. Ophthalmic history and intraoperative photography revealed pars plana cicatrization of haptics. Despite removal of trans-scleral prolene fixation sutures and application of gentle traction, the posterior chamber lens haptics remained firmly adherent to pars plana retina. The haptics were amputated to prevent significant chorioretinal damage. The conventional belief that all sewn-in posterior chamber intraocular lenses cause little or no scarring response around the haptics may be unfounded.

  6. Influence of various anesthetic drugs on the intraocular pressure of cats.

    Science.gov (United States)

    Hahnenberger, R W

    1976-04-14

    Cats with one normal eye and one eye with experimental glaucoma were trained to tolerate tonometry while conscious. They were then given the general anesthetic agents pentobarbital, ketamine, and CI-744 in the lowest and twice the lowest dosages which permitted tonometry in untrained cats. Pentobarbital lowered intraocular pressure (IOP) by 20-50%. Ketamine raised IOP by about 10%. CI-744 had essentially no effect on IOP. The two conpoments of CI-744, tiletamine (CI-634) and zolazepam (CI-716) were given individually in the doses in which they had been given as part of CI-744. Tiletamine had no effect on IOP, while zolazepam lowered IOP by about 10%. PMID:1083696

  7. Carbachol as miotic agent in intra-ocular lens implant surgery

    Directory of Open Access Journals (Sweden)

    Agarwal Jitendra

    1988-01-01

    Full Text Available The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens im-plant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:

  8. Twenty-four-hour intraocular pressure patterns in a symptomatic patient after ab interno trabeculotomy surgery

    Directory of Open Access Journals (Sweden)

    Mansouri K

    2014-11-01

    Full Text Available Kaweh Mansouri,1 Felipe A Medeiros,2 Robert N Weinreb2 1Glaucoma Sector, Department of Ophthalmology, Geneva University Hospitals, Geneva, Switzerland; 2Hamilton Glaucoma Center and Department of Ophthalmology, University of California, San Diego, La Jolla, CA, USA Abstract: We report the results of repeated ambulatory continuous 24-hour intraocular pressure (IOP monitoring with a contact lens sensor (CLS in a glaucoma patient with ocular pain after ab interno trabeculotomy (Trabectome™ surgery. Our findings show that a combined prostaglandin–pilocarpine treatment reduced nighttime IOP peaks and relieved the patient’s symptoms. Keywords: 24-hour, Trabectome contact lens sensor, prostaglandin–pilocarpine treatment

  9. The Comprehensive Control of Astigmatism during and Following Intraocular Lens Implantation.

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    The operating corneoloscope and Terry operative keratometer were used respectively in 29 and 34 eyes during the intraocular lens implantation to measure the corneal astigmatism qualitatively or quantitatively,so that the tension of incision closure could be adjusted. The surgically induced astigmatism in qualitative group two weeks after the operation was 3. 5 ± 1. 70 D and that in quantitative group was 2. 56±1. 60 D. There were 55.17% and 38. 24% of the eyes with over 2. 00 D corneal astigmatism in qu...

  10. The Clinical Analysis of Secondary Glaucoma Following Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    We present 14 patients with secondary gluacoma following the implantation of a posterior chamber intraocular lens (lOLs). All patients were u-nilateral gluacoma , which developed within 1 month following the IOL implantation in 10 cases, and from 1 to 3 years in 4 cases. The angle of anterior chamber was open in 8 patients, and close in 6 ones. Seven patients required treatment of antiglaucomatous medicine; 4 patients underwent laser indecto-my and 3 patients required antiglaucoma surgery. The results s...

  11. An investigation on dysphotopsia of a sigma-edged intraocular lens

    Institute of Scientific and Technical Information of China (English)

    Zhishan Gao; Meimei Kong; Xinhua Li; Lei Chen; Rihong Zhu

    2006-01-01

    @@ A sigma-edged design of intraocular lens (IOL) is proposed to minimize the reflected glare images associated with the edge. The optimal sigma inverse edge is investigated when pupil diameter is 5.0 mm by the established Escudero-Sanz's wide angle model. The non-sequential ray tracing program of Zemax-EE (Zemax Development Corp., San Diego, USA) is used to investigate the sigma edge of reducing the potential for edge glare phenomena. The results show that sigma-edged design can significantly reduce the reflected glare intensity on retina if the angle of its inverse edge is taken from 20 to 70 degrees.

  12. Recent decreasing frequency of enucleation for intraocular retinoblastoma in Upper Egypt

    International Nuclear Information System (INIS)

    To evaluate the efficacy of combined systematic chemotherapy (chemoreduction) and local ophthalmic therapy (LT) is preventing or delaying external beam radiotherapy (EBRT) and enucleation in patients with intraocular retinoblastoma. This was a prospective, nonrandomized, single-institution, clinical study. Twenty-eight patients (37 eyes) with newly diagnosed intraocular retinoblastoma were included in this study. Primary enucleation was performed for 7 eyes with advanced intraocular retinoblastoma at presentation before starting chemoreduction. Using Reese-Ellsworth (RE) staging for RB, the remaining 30 eyes were as follows: Two in group I, 3 in group II, 8 in group III, 7 in group IV, and 9 in group V. All the 30 eyes were initially treated with 6 cycles of chemoredution using vincristine, etoposide and carboplatin, repeated every three weeks. After total of 6 cycles, each tumor was re-evaluated decide on the next mode of therapy. In cases where the tumor was reduced enough, LT (Thermotherapy, or cryotherapy, but plaque radiotherapy was unavailable) was applied. In cases where the tumor was reduced but insufficient for LT, we added another 3 cycles of same regimen in some patients; or we performed chemotherapy (CTT) for others, according to size of the residual tumor. Eyes failed to respond to tochemorduction and LT, received EBRT or were enucleated. Following 6 cycles of chemoreduction, all tumors showed an initial regression, and all vitreous and subretinal seeds showed calcification or disappearance of most of them. Among the 30 eyes, 12 eyes achieved complete response (CR), and 18 eyes achieved partial response (PR). Only 7 eyes (stage I to III) showed sufficient reduction of tumor size for the LT to be applied for, for which, TTT (4 eyes), and cryotherapy (3 eyes) were performed. Chemotherapy (CTT) was performed for 9 patients (13 eyes, 15 tumors). At the end of follow-up period, 14 of the total 30 eyes (46.7%) could not be salvaged with chemoreduction and LT

  13. A Rapid and Convenient Procedure to Evaluate Optical Performance of Intraocular Lenses

    OpenAIRE

    Frank Schaeffel; Hakan Kaymak

    2014-01-01

    A new portable lens scanner was developed and tested for measuring focal lengths and relative contrast transfer of mono- and multifocal intraocular lenses (IOLs). A photograph of a natural scene was imaged in white light through an IOL in a water-filled cuvette, with their +21D base power largely neutralized by a −20D trial lens, using a USB monochrome video camera that could be focused via a laptop-controlled stepping motor from −8.5 to + 8.0D. The output of 10000 ON-OFF antagonistic “recept...

  14. Retropupillary iris-claw intraocular lens in ectopia lentis in Marfan syndrome

    Science.gov (United States)

    Faria, Mun Yueh; Ferreira, Nuno; Neto, Eliana

    2016-01-01

    Objective To report visual outcomes, complication rate, and safety of retropupillary iris-claw intraocular lens (ICIOL) in ectopia lentis in Marfan syndrome (MFS). Design Retrospective study. Methods Six eyes of three MFS patients with ectopia lentis underwent surgery for subluxation lens and retropupillary ICIOL implantation from October 2014 to October 2015 at the Department of Ophthalmology, Santa Maria Hospital in Lisbon, Portugal. Demographics, preoperative and postoperative best-corrected visual acuity (BCVA), and intraocular pressure were evaluated. Endothelium cell count was assessed using specular microscopy; anterior chamber depth was measured using Pentacam postoperatively; and intraocular lens position was viewed by ultrasound biomicroscopy. All patients were female; mean age was 20±14.264 years (range: 7–38 years). Results The average follow-up period was 6.66 months (range: 4–16 months). Preoperative BCVA was 0.568±0.149 logMAR units, and postoperative BCVA was 0.066±0.121 logMAR units. The mean BCVA gain was −0.502±0.221 on the logMAR scale. Postoperative average astigmatism and intraocular pressure were 1.292±0.697 mmHg (range: 0.5–2.25 mmHg) and 16 mmHg (range: 12–18 mmHg), respectively. The average endothelial cell density decreased from 3,121±178 cells/mm2 before surgery to 2,835±533 cells/mm2 after surgery (measured at last follow-up visit) and in the last follow-up, representing an average endothelial cell loss of 9.16%. Mean anterior chamber depth was 4.01 mm (±0.77 mm), as measured by Pentacam. No complications were found intra- or postoperatively in any of the six studied eyes. Conclusion Retropupillary ICIOL implantation is a safe and effective procedure in the treatment of aphakia in MFS eyes, without capsular support after surgery for ectopia lens. The six eyes that underwent lensectomy and retropupillary ICIOL implantation have had excellent visual outcomes with no complications so far. PMID:27382335

  15. Fungal endophthalmitis caused by Paecilomyces variotii, in an immunocompetent patient, following intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Anita K

    2010-01-01

    Full Text Available We report the case of a 70-year-old man who was admitted for anterior endophthalmitis following an intraocular lens implantation. He had developed a fluffy growth resembling a fungal mass on the iris of the right eye. The mass was removed and sent for fungal studies to our department. Direct microscopy revealed hyphae. Further studies helped identify the fungus to belong to genus Paecilomyces. This is a rare case of fungal endophthalmitis caused by Paecilomyces variotii in an immunocompetent person.

  16. Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Lucien A. M. van Philips

    2011-01-01

    Full Text Available Toxic anterior segment syndrome (TASS developed in four cases after uneventful implantation of a foldable iris-fixated phakic intraocular lens (pIOL. Two cases occurred sequentially in one patient. The TASS subsided without complications in all cases after intensive topical steroid treatment. A multitude of possible causes is considered for the occurrence of these TASS cases. From the sterilization and cleaning of surgical instruments to the possibility of endotoxines in ophthalmic viscosurgical devices (OVD. These rare cases should alert the surgeon to the possibility of TASS after pIOL implantation.

  17. Experimentally observe the effect of spherical aberration on diffractive intraocular lens using adaptive optics

    Science.gov (United States)

    Guo, Huanqing; DeLestrange, Elie

    2015-03-01

    We first investigated the similarity in optical quality of a batch of diffractive intraocular lenses (DIOLs), providing experimental evidence for one DIOL as representative of a batch. Using adaptive optics, we then evaluated one DIOL under different levels of Zernike spherical aberration (SA) by applying both a point spread function test and a psychophysical visual acuity test. We found that for small aperture size SA has the effect of shifting the through-focus curve of DIOL. Also, for a relatively large aperture size, it has different effects on the distant and near foci.

  18. Measurement of intraocular distances in human eyes by using Fourier domain low-coherence interferometry

    Science.gov (United States)

    Feng, Liang; Zhu, Lida; Li, Qinghua; Ma, Zhenhe; Wang, Bo; Wang, Yi

    2016-03-01

    We introduce a system for rapidly measuring the intraocular distances of human eyes in vivo with high sensitivity by using Fourier domain low-coherence interferometry. The system mainly consisting of a rapid focus displacement unit and a reference arm which has a variable optical path length. This system is capable of providing a complete biometrical assessment of a human eye in a single measurement procedure, including cornea thickness, anterior chamber depth, lens thickness, and axial length. The system is experimentally verified by measuring the four parameters of a human eye in vivo.

  19. A time-delay calibrated method for cornea hysteresis and intraocular pressure measurement

    Science.gov (United States)

    Wang, Kuo-Jen; Tsai, Che-Liang; Wang, Wai; Hsu, Long; Hsu, Ken-Yuh

    2016-04-01

    The presence of cornea hysteresis (CH) in characterizing the intraocular pressure (IOP) of a human eye deteriorates the accuracy of IOP. To suppress CH, the pressure gauge of a tonometer must be located as close as possible to the cornea. However, this arrangement is unpractical because appropriate working distance to the cornea is required. In this paper, a time-delay calibrated (TDC) method is proposed to counteract the undesired effect of CH in characterizing the IOP. Employing this TDC method, the CH approaches to zero for most eyes measured.

  20. Design, synthesis, and evaluation of NO-donor containing carbonic anhydrase inhibitors to lower intraocular pressure.

    Science.gov (United States)

    Huang, Qinhua; Rui, Eugene Y; Cobbs, Morena; Dinh, Dac M; Gukasyan, Hovhannes J; Lafontaine, Jennifer A; Mehta, Saurabh; Patterson, Brian D; Rewolinski, David A; Richardson, Paul F; Edwards, Martin P

    2015-03-26

    The antiglaucoma drugs dorzolamide (1) and brinzolamide (2) lower intraocular pressure (IOP) by inhibiting the carbonic anhydrase (CA) enzyme to reduce aqueous humor production. The introduction of a nitric oxide (NO) donor into the alkyl side chain of dorzolamide (1) and brinzolamide (2) has led to the discovery of NO-dorzolamide 3a and NO-brinzolamide 4a, which could lower IOP through two mechanisms: CA inhibition to decrease aqueous humor secretion (reduce inflow) and NO release to increase aqueous humor drainage (increase outflow). Compounds 3a and 4a have shown improved efficacy of lowering IOP in both rabbits and monkeys compared to brinzolamide (2). PMID:25728019

  1. Additive Effect of Brinzolamide on Diurnal Changes in Intraocular Pressure in Latanoprost-treated Eyes

    OpenAIRE

    Abe, Keitetsu; Kashiwagi, Kenji

    2008-01-01

    To investigate the effect of brinzolamide on diurnal fluctuations in the intraocular pressure (IOP) in patients on latanoprost ophthalmic solution prospectively was aimed. Eleven patients with primary open angle glaucoma were enrolled in this study. The subjects were admitted to the hospital and had their IOPs measured over 24 hours (10 AM, noon, 2 PM, 4 PM, 6 PM, 8 PM, 10 PM, midnight, 3 AM, 6 AM, and 8AM). After topical administration of brinzolamide twice daily for 4-8 weeks for one eye, t...

  2. Genome-wide association study of intraocular pressure identifies the GLCCI1/ICA1 region as a glaucoma susceptibility locus.

    OpenAIRE

    Blue Mountains Eye Study (BMES); Wellcome Trust Case Control Consortium; Strange, A; Bellenguez, C; Freeman, C.; Pirinen, M.; Su, Z.; Band, G.; Pearson, R; Vukcevic, D.; Rautanen, A; Spencer, CC; Donnelly, P

    2013-01-01

    To discover quantitative trait loci for intraocular pressure, a major risk factor for glaucoma and the only modifiable one, we performed a genome-wide association study on a discovery cohort of 2175 individuals from Sydney, Australia. We found a novel association between intraocular pressure and a common variant at 7p21 near to GLCCI1 and ICA1. The findings in this region were confirmed through two UK replication cohorts totalling 4866 individuals (rs59072263, P(combined) = 1.10 × 10(-8)). A ...

  3. natural or artificial diets

    Directory of Open Access Journals (Sweden)

    A. O. Meyer-Willerer

    2005-01-01

    Full Text Available Se probaron alimentos artificiales y naturales con larva de camarón (Litopenaeus vannamei cultivados en diferentes recipientes. Estos fueron ocho frascos cónicos con 15L, ocho acuarios con 50L y como grupo control, seis tanques de fibra de vidrio con 1500L; todos con agua marina fresca y filtrada. La densidad inicial en todos los recipientes fue de 70 nauplios/L. Aquellos en frascos y acuarios recibieron ya sea dieta natural o artificial. El grupo control fue cultivado con dieta natural en los tanques grandes que utilizan los laboratorios para la producción masiva de postlarvas. El principal producto de excreción de larva de camarón es el ión amonio, que es tóxico cuando está presente en concentraciones elevadas. Se determinó diariamente con el método colorimétrico del indofenol. Los resultados muestran diferencias en la concentración del ión amonio y en la sobrevivencia de larvas entre las diferentes dietas y también entre los diferentes recipientes. En aquellos con volúmenes pequeños comparados con los grandes, se presentó mayor concentración de amonio (500 a 750µg/L, en aquellos con dietas naturales, debido a que este ión sirve de fertilizante a las algas adicionadas, necesitando efectuar recambios diarios de agua posteriores al noveno día de cultivo para mantener este ión a una concentración subletal. Se obtuvo una baja cosecha de postlarvas (menor a 15% con el alimento artificial larvario, debido a la presencia de protozoarios, alimentándose con el producto comercial precipitado en el fondo de los frascos o acuarios. Los acuarios con larvas alimentadas con dieta natural también mostraron concentraciones subletales de amonio al noveno día; sin embargo, la sobrevivencia fue cuatro veces mayor que con dietas artificiales. Los tanques control con dietas naturales presentaron tasas de sobrevivencia (70 ± 5% similares a la reportada por otros laboratorios.

  4. An ACO model for a non-stationary formulation of the single elevator problem

    OpenAIRE

    Molina, Silvia; Leguizamón, Mario Guillermo; Alba Torres, Enrique

    2007-01-01

    The Ant Colony Optimization (ACO) metaheuristic is a bio-inspired approach for hard combinatorial optimization problems for stationary and non-stationary environments. In the ACO metaheuristic, a colony of artificial ants cooperate for finding high quality solutions in a reasonable time. An interesting example of a non-stationary combinatorial optimization problem is the Multiple Elevators Problem (MEP) which consists in finding a sequence of movements for each elevator to perform in a buildi...

  5. Meta analysis on effect of caffeine on intraocular pressure in patients with glaucoma%咖啡因对青光眼患者眼压影响的Meta分析

    Institute of Scientific and Technical Information of China (English)

    熊海波; 易虹; 刘鑫; 代喻兵

    2015-01-01

    目的:评价咖啡因对青光眼患者眼压的影响。方法通过计算机检索 The Cochrane Library、PubMed、Embase、中国期刊全文数据库(CNKI)、中国科技期刊全文数据库(VIP)、万方数据库、中国生物医学文献数据库(CBM)从建库至2014年9月的相关文献,纳入口服咖啡因咖啡的随机对照试验(RCT),用RevMan5.2软件对咖啡因对青光眼患者眼压的影响进行M eta分析。结果共纳入3个研究,均为交叉试验。M eta分析结果显示,青光眼患者口服咖啡因咖啡后1 h (W M D1.58,95% C I 0.70~2.47)及1.5 h (W M D1.46,95% C I 1.20~1.72)眼压均有升高。结论咖啡因有升高青光眼患者眼压的作用。%Objective To evaluate the effect of caffeine on intraocular pressure in the patients with glaucoma . Methods The related literatures in the Cochrane Library ,PubMed ,Embase ,CNKI ,VIP ,Wan Fang database and CBM from the establishment to September 2014 were retrieved ,then the included randomized controlled trial(RCT) on the effect of caffeine on intraocular pressure in patients with glaucoma were performed the Meta analysis by using RevMan 5 .2 software .Results A total of 3 crossover trials were included .The results of Meta analysis showed that the intraocular pressure(IOP) was elevated at 1 h (WMD 1 .58 ,95% CI 0 .70 -2 .47) ,1 .5 h (WMD 1 .46 ,95% CI 1 .20-1 .72) after orally taking caffeine in glaucoma patients .Conclusion The caffeine has the effect for elevating IOP in the patients with glaucoma .

  6. [Research and development of artificial retina material].

    Science.gov (United States)

    Hu, Ning; Yang, Jun; Peng, Chenglin; Wang, Xing; Zhang, Sijie; Zhang, Ying; Zheng, Erxin

    2008-04-01

    The application of artificial retina was introduced. The principal characteristics of artificial retina material were reviewed in particular. Moreover, the recent research development and application prospect were discussed.

  7. The Relation of the Location of Haptics of Posterior Chamber Intraocular Lenses and Peripheral Anterior Synechia

    Institute of Scientific and Technical Information of China (English)

    RuiduanLiao; ShaozhenLi

    1995-01-01

    Purpose:To investigate the occurrence,outcome and influencial factors of the pe-ripheral anterior synechia(PAS)following implantation of posterior chamber in-traocular lenses for finding a way to reduce thePAS.Subjects;40 eyes of 38senile cataract patients with normal chamber angle and in-traocular pressue(IOP)preoperatively were examined.Methods:Extracapsular cataract extraction was performed under microscope with insertion of a posterior chamber lens implant vaulted anteriorly by 10°.Go-nioscopy and slit-lamp examination and photography of the operated eyes were performed 3to 6months postoperatively.Results:PAS were found in 20(50%)of the 40eyes.Among the 20eyes with PAS the locations of 23haptics in17eyes corresponded with those of the PAS.PAS were seen more frequently with vertically sulcus-fixated haptics than with the horizontally capsular-fixated haptics.showing a significant difference(P<0.05).88%of the eyes withPAS had pupillary edformation,but their visual acuities and IOP were not affected.Conclusions:PAS is more likely to occur with vertically sulcus-fixated IOL.Rotat-ing the capsular-fixated haptics to the horizontal position may reduce the inci-dence of PAS.Gonioscopy should be a routine follow-up examination.

  8. Intraocular pressure determination in clinically normal red-footed tortoise (Geochelone carbonaria).

    Science.gov (United States)

    Selmi, André L; Mendes, Guilherme M; McManus, Concepta; Arrais, Patrícia

    2002-03-01

    Intraocular pressure (IOP) reflects a balance between aqueous humor production and outflow and is often an essential ophthalmic diagnostic procedure in animals. The objective of this study was to estimate IOP in clinically normal red-footed tortoises (Geochelone carbonaria) of various sizes by using applanation tonometry. Intraocular pressures were estimated for 25 captive red-footed tortoises (10 males, 10 females, and 5 animals of unknown sex) by using an applanation tonometer after topical anesthesia. Body length ranged from 5.1 to 54.9 cm, measured from nuchal to anal scutes. Five measurements from each eye were obtained by a single observer in an ambient temperature of approximately 30 degrees C. Observer's reliability was good (intraclass r = 0.75), and IOP did not change over the ordered sequence of five replicate measurements. For individual tortoises the correlation for IOP between the left and right eyes was low (r = 0.20). The paired t-test did not show any statistical effect (P = 0.426) for the difference in IOP between the left and right eyes. Mean IOP determined for 10 confirmed males and 10 confirmed females did not differ between sexes (P = 0.244). The mean IOP of five small tortoises ( 10 cm long). In red-footed tortoises there does not appear to be any relation between carapace length and IOP. PMID:12216794

  9. Laser flare photometry: a noninvasive, objective, and quantitative method to measure intraocular inflammation.

    Science.gov (United States)

    Tugal-Tutkun, Ilknur; Herbort, Carl P

    2010-10-01

    Aqueous flare and cells are the two inflammatory parameters of anterior chamber inflammation resulting from disruption of the blood-ocular barriers. When examined with the slit lamp, measurement of intraocular inflammation remains subjective with considerable intra- and interobserver variations. Laser flare cell photometry is an objective quantitative method that enables accurate measurement of these parameters with very high reproducibility. Laser flare photometry allows detection of subclinical alterations in the blood-ocular barriers, identifying subtle pathological changes that could not have been recorded otherwise. With the use of this method, it has been possible to compare the effect of different surgical techniques, surgical adjuncts, and anti-inflammatory medications on intraocular inflammation. Clinical studies of uveitis patients have shown that flare measurements by laser flare photometry allowed precise monitoring of well-defined uveitic entities and prediction of disease relapse. Relationships of laser flare photometry values with complications of uveitis and visual loss further indicate that flare measurement by laser flare photometry should be included in the routine follow-up of patients with uveitis. PMID:19430730

  10. Transconjunctival sutureless intrascleral intraocular lens fixation using intrascleral tunnels guided with catheter and 30-gauge needles.

    Science.gov (United States)

    Takayama, Kohei; Akimoto, Masayuki; Taguchi, Hogara; Nakagawa, Satoko; Hiroi, Kano

    2015-11-01

    We invented a new method for fixing an intraocular lens (IOL) in the scleral tunnel without using a wide conjunctival incision. Modified bent catheter needles were used to penetrate the IOL haptics through the sclerotomy sites. The IOL haptics were inserted into 30-guage (G) scleral tunnels guided by double 30-G needles piercing the sclera. All procedures were performed through the conjunctiva without wide incision. The procedure does not require special forceps, trocars or fibrin glue, only catheter and 30-G needles. The aid of an assistant was not required to support the IOL haptic. The procedures were easily learnt based on our previous method. As with other transconjunctival sutureless surgeries, patients feel less discomfort and the conjunctiva can be conserved for future glaucoma surgery. Complications included two cases of vitreous haemorrhage (16.7%), and one case each of postoperative hypotony, and iris capture (8.3%). Astigmatism induced by intraocular aberration was the same as we reported previously. Our method for fixing the IOL into the scleral tunnel is innovative, less expensive, less invasive and quick. This modified method is a good alternative for fixing IOL haptics into the sclera.

  11. Spectral analysis and comparison of mineral deposits forming in opacified intraocular lens and senile cataractous lens

    Science.gov (United States)

    Lin, Shan-Yang; Chen, Ko-Hwa; Lin, Chih-Cheng; Cheng, Wen-Ting; Li, Mei-Jane

    2010-10-01

    This preliminary report was attempted to compare the chemical components of mineral deposits on the surfaces of an opacified intraocular lens (IOL) and a calcified senile cataractous lens (SCL) by vibrational spectral diagnosis. An opacified intraocular lens (IOL) was obtained from a 65-year-old male patient who had a significant decrease in visual acuity 2-years after an ocular IOL implantation. Another SCL with grayish white calcified plaque on the subcapsular cortex was isolated from a 79-year-old male patient with complicated cataract after cataract surgery. Optical light microscope was used to observe both samples and gross pictures were taken. Fourier transform infrared (FT-IR) and Raman microspectroscopic techniques were employed to analyze the calcified deposits. The curve-fitting algorithm using the Gaussian function was also used to quantitatively estimate the chemical components in each deposit. The preliminary results of spectral diagnosis indicate that the opacified IOL mainly consisted of the poorly crystalline, immature non-stoichiometric hydroxyapatite (HA) with higher content of type B carbonated apatites. However, the calcified plaque deposited on the SCL was comprised of a mature crystalline stoichiometric HA having higher contents of type A and type B carbonate apatites. More case studies should be examined in future.

  12. Study on intra-ocular lens aberration measurement in-air

    Science.gov (United States)

    Wang, Yuanyuan; Chen, Jiaojie; Fen, Haihua; Hu, Chuan; Li, Yiyi

    2010-10-01

    In clinical ophthalmology, the wavefront aberration of human eyes is expressed by Zernike polynomial after cataract surgery and intraocular lens implantation, the human eyes aberration will change. The problem of objective evaluation of wavefront aberration introduced by the Intra-ocular (IOL) in-vivo remains unsolved. This paper introduced the measurement principal of IOL wavefront aberration with expression by Zernike polynominal in air. A Hartmann-Shack wavefront sensor system was constructed to measure the wavefront of IOL and to get the corresponding grid patterns. After a series of computer image processing steps, 7th order with 35 items Zernike coefficients was obtained. The IOL of 20.0D power was measured 5 times by this system to get the spherical aberration about 6.73+/-0.02μm, demonstrating the good repeatability of the system. Ten IOLs with the same 20.0D power but difference in surface curvature were chosen for measurement. The spherical aberration observed were in the range of 2.74μm-11.26μm. These results are valuable for the optical design of IOLs and the aberration analysis of human eyes post-operation.

  13. Sutureless intrascleral intraocular lens fixation with lamellar dissection of scleral tunnel

    Directory of Open Access Journals (Sweden)

    Kawaji T

    2016-01-01

    Full Text Available Takahiro Kawaji,1,2 Tomoki Sato,2 Hidenobu Tanihara11Department of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Chuo-ku, 2Sato Eye & Internal Medicine Clinic, Kumamoto, JapanPurpose: To report the results of sutureless scleral fixation of a posterior chamber intraocular lens (IOL by using our developed simple technique.Methods: We retrospectively reviewed the medical records of 48 eyes of 47 patients who underwent sutureless intrascleral IOL fixation by using our modified technique. A 25-gauge microvitreoretinal knife was used to perform sclerotomies and create limbus-parallel scleral tunnels with lamellar dissection in which the haptics were fixed.Results: The IOLs were fixed and centered well. The mean follow-up period was 26.7 months. Postoperative complications included smooth vitreous hemorrhage in four eyes (8.3%, cystoid macular edema in two eyes (4.2%, and iris capture of the IOL in two eyes (4.2%. No other complications, such as breakage of the IOL, spontaneous IOL dislocation, or retinal detachment, were detected during the follow-up period.Conclusion: The lamellar dissection of the limbus-parallel scleral tunnel can simplify the forceps-assisted introduction of the haptics into the scleral tunnel, and this technique seemed to be safe.Keywords: intraocular lenses, ophthalmologic surgical procedures, intrascleral fixation, sutureless fixation

  14. Solid Lipid Nanoparticles Improve the Diclofenac Availability in Vitreous after Intraocular Injection

    Science.gov (United States)

    Abrishami, Majid; Vakili Ahrari Roodi, Mohammad

    2016-01-01

    Purpose. In order to improve the drug availability after intravitreal administration, solid lipid nanoparticles (SLNs) containing diclofenac were prepared. Methods. In this experimental study, 18 albino rabbits were included. In right and left eyes of all rabbits, SLNs containing diclofenac and commercial form of diclofenac (0.3 mg drug) were intravitreally injected, respectively. One, four, twelve, twenty-four, and forty-eight hours after injection, vitreous and aqueous humor samples were obtained in all cases. Then, the concentration of diclofenac sodium was evaluated in all samples. Results. Size of nanoparticles was around 170 nm after preparation. Drug concentration in eyes injected with SLNs was significantly higher than left eyes injected with commercial formulation up to 4 hours after intravitreal injection (p < 0.05). Diclofenac was quantified in samples up to 48 hours after intraocular injection. Four hours after intravitreal injection, the concentration of diclofenac in vitreous and aqueous humor of eyes receiving SLNs was, respectively, 2.5 and 6.5 times higher than eyes injected with commercial form of drug. Conclusions. Here, we demonstrate the potential of SLNs as a carrier of diclofenac for intraocular injection in order to prevent the systemic effects of the drug, increase the injection intervals, and improve the patient compliance.

  15. A retrospective analysis of the first Indian experience on Artisan phakic intraocular lens

    Directory of Open Access Journals (Sweden)

    Senthil Sirisha

    2006-01-01

    Full Text Available Purpose: To evaluate the efficacy, safety, predictability and stability of implanting a polymethylmethacrylate phakic intraocular lens (PIOL in high myopia. Materials and Methods: A retrospective analysis of the data of patients who underwent Artisan phakic IOL implantation between 2002 and 2003 with a follow-up of at least 24 months. Results: An Artisan myopia lens was implanted in 60 eyes of 36 patients with preoperative myopia ranging from -5.0 to -24.0 D. Mean patient age was 22.6 years. Mean spherical equivalent of manifest refraction stabilized by the first postoperative week. At three months follow-up, 54 eyes (90% had a postoperative refraction within ± 1D emmetropia and 45 eyes (75% had uncorrected visual acuity of 20/40 or better. Seven eyes (11.6% had loss of one Snellen line and none had loss of two Snellen lines or more at three months. The mean endothelial cell loss was 3.8% at three months, 5.2% at six months, 5.25% at 12 months and 6.38% at two years, which was not significant. Postoperative complications included anterior chamber reaction in two eyes (3.3%, rise in intraocular pressure in six eyes (10% and dislocation of PIOL in two eyes (3.3%. Conclusion: Implantation of Artisan myopia lens to correct high myopia resulted in a stable and fairly predictable refractive outcome with few complications. Significant endothelial damage was not detected in two years of follow-up.

  16. Customized toric intraocular lens implantation for correction of extreme corneal astigmatism due to corneal scarring

    Directory of Open Access Journals (Sweden)

    R Bassily

    2010-03-01

    Full Text Available R Bassily, J LuckOphthalmology Department, Royal United Hospital, Combe Park, Bath, UKAbstract: A 76-year-old woman presented with decreased visual function due to cataract formation. Twenty-five years prior she developed right sided corneal ulceration that left her with 10.8 diopters (D of irregular astigmatism at 71.8° (steep axis. Her uncorrected visual acuity was 6/24 and could only ever wear a balanced lens due to the high cylindrical error. Cataract surgery was planned with a custom designed toric intraocular lens (IOL with +16.0 D sphere inserted via a wound at the steep axis of corneal astigmatism. Postoperative refraction was -0.75/+1.50 × 177° with a visual acuity of 6/9 that has remained unchanged at six-week follow-up with no IOL rotation. This case demonstrates the value of high power toric IOLs for the correction of pathological corneal astigmatism.Keywords: intraocular lens, corneal ulceration, visual acuity, scarring

  17. Iris-claw intraocular lens implantation: Anterior chamber versus retropupillary implantation

    Science.gov (United States)

    Helvacı, Sezer; Demirdüzen, Selahaddin; Öksüz, Hüseyin

    2016-01-01

    Purpose: To compare the outcomes of anterior chamber and retropupillary implantation of iris-claw Artisan intraocular lenses (IOL). Design: Prospective, randomized, single-blinded study. Patients and Methods: Forty eyes of forty aphakic patients were enrolled. Patients were randomized into two groups. Each group includes twenty patients. Group 1 received anterior chamber Artisan IOL implantation. Group 2 received retropupillary Artisan IOL implantation. Preoperative and postoperative corrected distance visual acuity (CDVA), intraocular pressure (IOP), and all complications were noted and compared at 6 months follow-up. Results: Each two groups obtained a significant improvement in CDVA (P < 0.05). Four patients in Group 1 and five patients in Group 2 had significant but nonpermanent increase at IOP values. There were one and two pupillary irregularity in Group 1 and Group 2, respectively. In one patient, a shallow and inferior located retinal detachment were encountered in anterior chamber group. Conclusions: The results were not significantly different between the two fixation techniques for iris-claw lens. The surgery procedure is dependent to surgeon experience and eye's conditions. PMID:26953023

  18. Hydrophilic Acrylic Intraocular Lens Opacification after Descemet Stripping Automated Endothelial Keratoplasty

    Science.gov (United States)

    Norouzpour, Amir; Zarei-Ghanavati, Siamak

    2016-01-01

    Purpose: To report hydrophilic acylic intraocular lens (IOL) opacification after Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in an eye with multiple prior intraocular surgeries and iatrogenic aniridia. Case Report: A 34-year-old woman with history of penetrating keratoplasty (PKP) for advanced keratoconus and subsequent Urrets-Zavalia Syndrome (UZS) underwent phacoemulsification and hydrophilic acrylic IOL implantation for her cataract. In order to control post-PKP glaucoma, multiple glaucoma surgeries including two glaucoma drainage implants were performed. As the original corneal graft failed, the patient subsequently underwent re-PKP. Four years later, she underwent DSAEK for treatment of the second graft failure. Ten months after DSAEK, a double semi-circular pattern of IOL opacification was observed on the anterior surface of the IOL. The patient did not report any complaints and we decided not to exchange the IOL. Conclusion: In an eye with UZS and iatrogenic aniridia, IOL opacification may result from direct contact between the IOL surface and exogenous air. Aniridia can be a risk factor for development of IOL opacification after DSAEK. Further studies are required to confirm this hypothesis. PMID:27413506

  19. Bioengineering of Artificial Lymphoid Organs.

    Science.gov (United States)

    Nosenko, M A; Drutskaya, M S; Moisenovich, M M; Nedospasov, S A

    2016-01-01

    This review addresses the issue of bioengineering of artificial lymphoid organs.Progress in this field may help to better understand the nature of the structure-function relations that exist in immune organs. Artifical lymphoid organs may also be advantageous in the therapy or correction of immunodefficiencies, autoimmune diseases, and cancer. The structural organization, development, and function of lymphoid tissue are analyzed with a focus on the role of intercellular contacts and on the cytokine signaling pathways regulating these processes. We describe various polymeric materials, as scaffolds, for artificial tissue engineering. Finally, published studies in which artificial lymphoid organs were generated are reviewed and possible future directions in the field are discussed.

  20. Artificial Immune Systems Tutorial

    CERN Document Server

    Aickelin, Uwe

    2008-01-01

    The biological immune system is a robust, complex, adaptive system that defends the body from foreign pathogens. It is able to categorize all cells (or molecules) within the body as self-cells or non-self cells. It does this with the help of a distributed task force that has the intelligence to take action from a local and also a global perspective using its network of chemical messengers for communication. There are two major branches of the immune system. The innate immune system is an unchanging mechanism that detects and destroys certain invading organisms, whilst the adaptive immune system responds to previously unknown foreign cells and builds a response to them that can remain in the body over a long period of time. This remarkable information processing biological system has caught the attention of computer science in recent years. A novel computational intelligence technique, inspired by immunology, has emerged, called Artificial Immune Systems. Several concepts from the immune have been extracted an...