WorldWideScience

Sample records for artificially elevated intraocular

  1. Visual functional changes during acute elevation of intraocular pressure

    Institute of Scientific and Technical Information of China (English)

    Tian-De SHOU

    2006-01-01

    Glaucoma is closely related to elevation of intraocular pressure (IOP). Many studies have done on the effect of chronic elevation of IOP on the retina and optic nerve, but less attention was paid to the effect of acute elevated IOP. Here we briefly review experimental studies on functional changes of the visual system from the retina to the visual cortex under acute elevated IOP condition, which is similar to that of acute primary angle-closure glaucoma.

  2. Use of betaxolol in the reduction of elevated intraocular pressure.

    Science.gov (United States)

    Radius, R L

    1983-06-01

    Forty eyes in 20 patients with elevated intraocular pressure were treated with either a 0.125% betaxolol ophthalmic solution or a placebo. After 2, 4, and 6 weeks of twice-daily therapy, the eyes receiving the betaxolol had a mean percent reduction in IOP greater than that in the eyes treated only with the drug vehicle (placebo). Both solutions were well tolerated.

  3. Refraction changes during elevation of intraocular pressure by suction cup, their reflection in the pattern visual evoked cortical potential and their compensation.

    Science.gov (United States)

    Bernd, A; Ulrich, W D; Teubel, H; Rohrwacher, F; Barth, T

    1993-01-01

    Visual evoked cortical potential studies using pattern stimuli with the intraocular pressure raised artificially by the suction cup method have been reported. Possible changes in the refraction of the eye due to the method employed and their influence on the pattern visual evoked cortical potential have not been considered. Changes in the refraction of the eye during artificial intraocular pressure elevation and the influence of such changes on pattern visual evoked cortical potentials were studied. The refraction changes were found to depend on the shape of the suction cup. They could be compensated for by employing properly shaped suction cups and contact lenses. The behavior of amplitude and latency of the pattern visual evoked cortical potential at artificially elevated intraocular pressure with compensation for refraction changes has been studied and found to depend in a characteristic manner on ocular perfusion pressure.

  4. An examination of the hypothesis that intraocular pressure elevation episodes can have prognostic significance in glaucoma suspects.

    Science.gov (United States)

    McMonnies, Charles

    2015-01-01

    The efficacy of intraocular pressure reduction in retarding the progression of glaucoma has been demonstrated. This review examines the potential for prognostic advantage for glaucoma suspects in reducing their optic nerve head exposure to elevated intraocular pressure associated with activities which have been shown to elevate intraocular pressure. In this observational study, patients examined at the Centre for Eye Health (University of New South Wales) with a diagnosis of glaucoma suspect were surveyed to determine their histories for participation in activities which are known to elevate intraocular pressure. The evidence regarding the pathological significance of these sources of elevation in susceptible patients was examined. Apart from the universality of sleep-related intraocular pressure elevations, the histories from 183 confirmed glaucoma suspects indicate a wide range and variation in frequency of participation in other intraocular pressure elevating activities. A reduction in exposure to elevated intraocular pressure may improve the prognosis for glaucoma suspects. Additional patient specific assessment of the results of this screening could provide an indication of the degree (frequency, intensity level and duration) of exposure to elevated intraocular pressure. Such information may provide the basis for improving a patient's prognosis by helping them to identify opportunities to reduce such exposure to elevated intraocular pressure. Any benefit of reduction of such exposure appears likely to be greater if activities which elevate intraocular pressure are of long duration, occur frequently, occur over a long period of time, and/or involve high levels of intraocular pressure elevation.

  5. Blood pressure modifies retinal susceptibility to intraocular pressure elevation.

    Directory of Open Access Journals (Sweden)

    Zheng He

    Full Text Available Primary open angle glaucoma affects more than 67 million people. Elevated intraocular pressure (IOP is a risk factor for glaucoma and may reduce nutrient availability by decreasing ocular perfusion pressure (OPP. An interaction between arterial blood pressure and IOP determines OPP; but the exact contribution that these factors have for retinal function is not fully understood. Here we sought to determine how acute modifications of arterial pressure will affect the susceptibility of neuronal function and blood flow to IOP challenge. Anaesthetized (ketamine:xylazine Long-Evan rats with low (∼60 mmHg, sodium nitroprusside infusion, moderate (∼100 mmHg, saline, or high levels (∼160 mmHg, angiotensin II of mean arterial pressure (MAP, n = 5-10 per group were subjected to IOP challenge (10-120 mmHg, 5 mmHg steps every 3 minutes. Electroretinograms were measured at each IOP step to assess bipolar cell (b-wave and inner retinal function (scotopic threshold response or STR. Ocular blood flow was measured using laser-Doppler flowmetry in groups with similar MAP level and the same IOP challenge protocol. Both b-wave and STR amplitudes decreased with IOP elevation. Retinal function was less susceptible to IOP challenge when MAP was high, whereas the converse was true for low MAP. Consistent with the effects on retinal function, higher IOP was needed to attenuated ocular blood flow in animals with higher MAP. The susceptibility of retinal function to IOP challenge can be ameliorated by acute high BP, and exacerbated by low BP. This is partially mediated by modifications in ocular blood flow.

  6. Clinical Analysis of Early and Mid-late Elevated Intraocular Pressure after Silicone Oil Injection

    Institute of Scientific and Technical Information of China (English)

    Lifei Wang; Jingjiang Liu; Tianxiang Lu

    2014-01-01

    Purpose:To discuss the incidence and clinical features of early and mid-late elevated intraocular pressure after pars plana vitrectomy and silicone oil injection, and to evaluate the clinical management of eyes with secondary glaucoma. Methods:.This was an observational consecutive case series of 691 eyes in 679 patients who were treated with pars plana vitrectomy and silicone injection...The diagnostic criteria of early elevated intraocular pressure after silicone oil injection was ≥21 mmHg two weeks after surgery, while mid-late ele-vated intraocular pressure was ≥21 mmHg after two weeks. The incidence and clinical management of elevated intraocular pressure were analyzed. Results: In total, 211 of 691 eyes (30.54%) developed ele-vated intraocular pressure two weeks after pars plana vitrecto my and silicone injection. Of the 211 eyes, 101 eyes (47.87%) had ocular inflammation, 64 eyes (30.33%) showed hyphema, 35 eyes(16.59%) had silicone oil in the anterior chamber, 6 eyes. (2.84% ).had excess silicone oil injected,.and 5 eyes (2.37%).had rubeosis irides. Eighty three of 691 eyes (12.01%). developed elevated intraocular pressure after two weeks..Of these 83 eyes, 25 eyes (30.12%) had rubeosis irides,.16 eyes (19.27%) had issues related to topic steroid therapy,.13 eyes . (15.66%).had a papillary block,.silicone oil in the anterior chamber,10 eyes (12.05%) had a silicone emulsion,.10 eyes (12.05% ).had peripheral anterior synchiae,.and 9 eyes (10.84%).had silicone oil in the anterior chamber..All eyes with elevated intraocular pressure were treated with antiglau-coma medications and surgeries. Conclusion:.The reasons for elevated intraocular pressure dif-fered between early and mid-late after pars plana vitrectomy and silicone oil injection. The elevated intraocular pressure can be controlled effectively by immediate diagnosis and proper treatment with medicine and operation.

  7. Mouse model of sustained elevation in intraocular pressure produced by episcleral vein occlusion.

    Science.gov (United States)

    Ruiz-Ederra, Javier; Verkman, A S

    2006-05-01

    We have developed an inducible mouse model of glaucoma based on episcleral vein cauterization (EVC). Intraocular pressure (IOP) elevation in adult mice was produced by cauterizing three episcleral veins. Serial IOP measurements were done by induction-impact tonometry. IOP was significantly elevated by 104+/-20% in 20 out of 23 mice (87%) within the first day after EVC, and remained elevated for 4 weeks, with mean IOP 94% higher in EVC-treated vs. contralateral control eyes. Aqueous outflow blockade was verified from the IOP response to pulsed fluid infusions into the anterior chamber. Retinal ganglion cell (RGC) loss, determined by retrograde labelling using Fluoro-Gold applied to the superior colliculous, was approximately 20% at 2 weeks after EVC. We conclude that episcleral vein occlusion in mice produces significant and sustained elevation in IOP associated with increased outflow resistance and RGC loss, and thus may be useful to model glaucoma in genetically modified and drug-treated mice.

  8. Combined transscleral fixation of an artificial iris prosthesis with an intraocular lens

    Directory of Open Access Journals (Sweden)

    Uzeyır Gunenc

    2016-02-01

    Full Text Available ABSTRACT Post-traumatic aniridia combined with aphakia may be seen after globe injury. Aside from esthetic aspects, partial or total loss of the iris tissue may also be related to various degrees of glare and photophobia. Such patients suffer from severe visual impairment secondary to aphakia. Herein we describe a novel surgical technique for the management of an aphakic eye with traumatic aniridia for a patient who underwent transscleral fixation of a custom-tailored artificial iris prosthesis combined with a rigid intraocular lens (IOL. Tight suturing of the IOL haptic eyelets on the silicone iris prosthesis and fixation of such a complex to the scleral wall may provide excellent cosmetic and functional outcomes in aphakic eyes with aniridia.

  9. Selective laser trabeculoplasty for elevated intraocular pressure following subtenon injection of triamcinolone acetonide

    Directory of Open Access Journals (Sweden)

    Kenya Yuki

    2010-03-01

    Full Text Available Kenya Yuki1, Makoto Inoue1,2, Daisuke Shiba1, Ryosuke Kawamura1, Susumu Ishida1, Yuichiro Ohtake11Department of Ophthalmology, Keio University School of Medicine, 2Kyorin Eye Center, Kyorin University School of Medicine, Mitaka, Tokyo, JapanPurpose: To report on the efficacy of selective laser trabeculoplasty (SLT for elevated intraocular pressure (IOP following subtenon injection of triamcinolone acetonide.Method: SLT was performed on four of 148 eyes in which IOP was elevated after a subtenon injection of triamcinolone acetonide and could not be maintained within normal limits by conventional medications. Postoperative IOP and relative reduction of IOP were evaluated.Results: IOP was reduced in three eyes to within the normal range without any medications six months after SLT alone, but trabeculotomy was performed on one eye. Percentage reduction in IOP after SLT was 21.6% at one month, 45.0% at three months, and 52.7% at nine months.Conclusion: SLT may be effective in reducing elevated IOP following subtenon injection of triamcinolone acetonide and should be considered before glaucoma surgery.Keywords: selective laser trabeculoplasty, steroid glaucoma, subtenon injection, triamcinolone acetonide

  10. Clinical Analysis of 106 Cases with Elevated Intraocular Pressure in Thyroid-associated Ophthalmopathy

    Institute of Scientific and Technical Information of China (English)

    Jianfeng He; Zhongyao Wu; Jianhua Yan; Huasheng Yang; Yuxiang Mao; Siming Ai; Zhicong Chen

    2004-01-01

    Purpose :To summarize the clinical manifestation of thyroid-associated ophthalmopathy (TAO) with elevated intraocular pressure (IOP), and to analyze the contributing factors.Methods: One hundred and six cases(188 eyes) of ocular hypertension in 339 cases(597eyes) with TAO were collected from 1994 to 2001 and their clinic manifestations were summarized and analyzed.Results:It was demonstrated that the incidence of ocular hypertension in TAO was 31.3%, and was more frequently found in the male than in the female. The elevated IOP in TAO was found to be partially related to compression of the eyeball by enlarged extraocular muscles, the elevated intraorbital pressure as result of the proliferation of intraorbital connective tissue and the enlargement as well as swelling of extraocular muscles. It was also related to the severity of TAO other than the course of TAO. The ocular hypertension in most cases can be controlled with reduction of IOP by methylprednisolone or orbital decompression.Conclusion: Specific clinical features were found in TAO patients with ocular hypertension. It should be differentiated with primary glaucoma. The IOP in most cases can be controlled by prompt and effective treatment of TAO. Eye Science 2004;20:10-14.

  11. Influence of different artificial lighting regimes on intraocular pressure circadian profile in the dog (Canis familiaris).

    Science.gov (United States)

    Piccione, Giuseppe; Giannetto, Claudia; Fazio, Francesco; Giudice, Elisabetta

    2010-01-01

    The present study was undertaken to determine the temporal variation in intraocular pressure (IOP) and if this variation is under circadian clock control. The authors exposed five female and five male Beagles to four different artificial lighting regimes: 12/12 light/dark (L/D) period, 12/12 D/L period, constant light, and constant darkness. IOP was measured at 3 h intervals over a 48-h period. Statistical analysis of the data was performed by multivariate ANOVA, one-way repeated measure ANOVA and by the single cosinor method. Results showed no statistical effect of gender, eye and photoperiod on IOP values. A significant effect of time for each gender and each eye during all lighting regimes was seen, except during constant light, and also robust daily rhythmicity of IOP values in all L/D periods, except during constant light. In conclusion IOP values in the dog show a circadian rhythm and this rhythm is driven by a central pacemaker.

  12. Haploinsufficient Bmp4 ocular phenotypes include anterior segment dysgenesis with elevated intraocular pressure

    Directory of Open Access Journals (Sweden)

    Nusinowitz Steven

    2001-11-01

    Full Text Available Abstract Background Glaucoma is a blinding disease usually associated with high intraocular pressure (IOP. In some families, abnormal anterior segment development contributes to glaucoma. The genes causing anterior segment dysgenesis and glaucoma in most of these families are not identified and the affected developmental processes are poorly understood. Bone morphogenetic proteins (BMPs participate in various developmental processes. We tested the importance of Bmp4 gene dosage for ocular development and developmental glaucoma. Results Bmp4+/- mice have anterior segment abnormalities including malformed, absent or blocked trabecular meshwork and Schlemm's canal drainage structures. Mice with severe drainage structure abnormalities, over 80% or more of their angle's extent, have elevated IOP. The penetrance and severity of abnormalities is strongly influenced by genetic background, being most severe on the C57BL/6J background and absent on some other backgrounds. On the C57BL/6J background there is also persistence of the hyaloid vasculature, diminished numbers of inner retinal cells, and absence of the optic nerve. Conclusions We demonstrate that heterozygous deficiency of BMP4 results in anterior segment dysgenesis and elevated IOP. The abnormalities are similar to those in human patients with developmental glaucoma. Thus, BMP4 is a strong candidate to contribute to Axenfeld-Rieger anomaly and other developmental conditions associated with human glaucoma. BMP4 also participates in posterior segment development and wild-type levels are usually critical for optic nerve development on the C57BL/6J background. Bmp4+/- mice are useful for studying various components of ocular development, and may allow identification of strain specific modifiers affecting a variety of ocular phenotypes.

  13. Ocular Decompression with Cotton Swabs Lowers Intraocular Pressure Elevation Following Intravitreal Injection

    Science.gov (United States)

    Gregori, Ninel Z.; Weiss, Matthew J.; Goldhardt, Raquel; Schiffman, Joyce C.; Vega, Edgardo; Mattis, Cherrie-Ann; Shi, Wei; Kelley, Linda; Hernandez, Vilma; Feuer, William J.

    2013-01-01

    Objective To determine the effect of pre-injection ocular decompression by cotton swabs on the immediate rise in intraocular pressure (IOP) after intravitreal injections. Methods Forty-eight patients receiving 0.05-ml ranibizumab injections in a retina clinic were randomized to two anesthetic methods in each eye on the same day (if bilateral disease) or on consecutive visits (if unilateral disease). One method utilized cotton swabs soaked in 4% lidocaine applied to the globe with moderate pressure and the other 3.5% lidocaine gel applied without pressure. IOPs were recorded at baseline (before injection) and at 0, 5, 10, and 15 minutes after the injection until the IOP was ≤30 mmHg. The IOP elevations from baseline were compared after the two anesthetic methods. Results The pre-injection mean IOP (SD, mmHg) was 15.5 (3.3) before the cotton swabs and 15.9 (3.0) before the gel (p=0.28). Mean IOP (SD, mmHg) change immediately after injection was 25.7 (9.2) after the cotton swabs and 30.9 (9.9) after the gel (P=0.001). Thirty-five percent of gel eyes had IOP ≥50 mmHg compared to only 10% of cotton swab eyes immediately after the injection (P<0.001). Conclusion Decompressing the eye with cotton swabs during anesthetic preparation prior to an intravitreal injection produces a significantly lower IOP spike after the injection. PMID:23632408

  14. Genetic context determines susceptibility to intraocular pressure elevation in a mouse pigmentary glaucoma

    Directory of Open Access Journals (Sweden)

    Cosma Ioan M

    2006-07-01

    Full Text Available Abstract Background DBA/2J (D2 mice develop an age-related form of glaucoma. Their eyes progressively develop iris pigment dispersion and iris atrophy followed by increased intraocular pressure (IOP and glaucomatous optic nerve damage. Mutant alleles of the Gpnmb and Tyrp1 genes are necessary for the iris disease, but it is unknown whether alleles of other D2 gene(s are necessary for the distinct later stages of disease. We initiated a study of congenic strains to further define the genetic requirements and disease mechanisms of the D2 glaucoma. Results To further understand D2 glaucoma, we created congenic strains of mice on the C57BL/6J (B6 genetic background. B6 double-congenic mice carrying D2-derived Gpnmb and Tyrp1 mutations develop a D2-like iris disease. B6 single-congenics with only the Gpnmb and Tyrp1 mutations develop milder forms of iris disease. Genetic epistasis experiments introducing a B6 tyrosinase mutation into the congenic strains demonstrated that both the single and double-congenic iris diseases are rescued by interruption of melanin synthesis. Importantly, our experiments analyzing mice at ages up to 27 months indicate that the B6 double-congenic mice are much less prone to IOP elevation and glaucoma than are D2 mice. Conclusion As demonstrated here, the Gpnmb and Tyrp1 iris phenotypes are both individually dependent on tyrosinase function. These results support involvement of abnormal melanosomal events in the diseases caused by each gene. In the context of the inbred D2 mouse strain, the glaucoma phenotype is clearly influenced by more genes than just Gpnmb and Tyrp1. Despite the outward similarity of pigment-dispersing iris disease between D2 and the B6 double-congenic mice, the congenic mice are much less susceptible to developing high IOP and glaucoma. These new congenic strains provide a valuable new resource for further studying the genetic and mechanistic complexity of this form of glaucoma.

  15. Tafluprost once daily for treatment of elevated intraocular pressure in patients with open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Liu Y

    2012-12-01

    Full Text Available Yang Liu, Weiming MaoDepartment of Cell Biology and Anatomy, North Texas Eye Research Institute, University of North Texas Health Science Center, Fort Worth, TXAbstract: Glaucoma is a leading cause of visual loss worldwide. Current antiglaucoma therapy focuses on lowering intraocular pressure to a safe level. In recent years, prostaglandin analogs have become the first-line agents for treating open angle glaucoma. Tafluprost, which was first reported in 2003, is a novel prostaglandin analog, and has been shown to be a potent ocular hypotensive agent in a number of preclinical and clinical studies. Also, its unique preservative-free formulation helps to decrease preservative-associated ocular disorders and improve patient compliance. In this review, studies from 2003 to 2012 focusing on the structure, metabolism, efficacy, and safety of tafluprost are summarized. These studies suggested that application of tafluprost once daily is a safe and effective treatment for patients with open angle glaucoma.Keywords: tafluprost, prostaglandin analog, glaucoma, intraocular pressure, preservative-free formulation

  16. The Management of a Patient with Elevated Intraocular Pressure Resistant to Medical Treatment: Anterior Chamber Irrigation

    Directory of Open Access Journals (Sweden)

    Abdullah Beyoğlu

    2014-10-01

    Full Text Available A 7-year-old male patient was medically treated in another center for hyphema which occurred after blunt trauma to his right eye. He was admitted to our clinic when his visual acuity decreased after being discharged. Biomicroscopic examination revealed total hyphema. Intraocular pressure (IOP was 48 mm Hg in the right eye with Goldmann applanation tonometry. Since IOP could not be managed by medical therapy and there was no regression in hyphema, anterior chamber was irrigated. As in our case, it should not be forgotten that re-hemorrhage may occur in the first week of hyphema during childhood. Moreover, surgical treatment should be considered when hemorrhage does not regress with medical treatment, increased IOP persists, and when there is a risk of corneal endothelial staining (corneal blood staining. (Turk J Ophthalmol 2014; 44: 400-2

  17. The effect of ageing on ocular blood flow, oxygen tension and retinal function during and after intraocular pressure elevation.

    Directory of Open Access Journals (Sweden)

    Jeremiah K H Lim

    Full Text Available PURPOSE: To investigate the effect of ageing on the recovery of ocular blood flow, intravitreal oxygen tension and retinal function during and after intraocular pressure (IOP elevation. METHODS: Long Evans rats (3- and 14-month-old underwent acute stepwise IOP elevation from 10 to 120 mmHg (5 mmHg steps each 3 minutes. IOP was then returned to baseline and recovery was monitored for 2 hours. Photopic electroretinograms (ERG were recorded at each IOP step during stress and at each minute during recovery. Ocular blood flow and vitreal oxygen tension (pO2 were assayed continuously and simultaneously using a combined laser Doppler flow meter (LDF and an oxygen sensitive fibre-optic probe, respectively. The combined sensor was placed in the vitreous chamber, proximal to the retina. Data were binned into 3 minute intervals during stress and 1 min intervals during recovery. Recovery data was described using a bi-logistic function. RESULTS: Rats of both ages showed similar susceptibility to IOP elevation, with pO2 showing a closer relationship to ERG than LDF. During recovery, both ages showed a distinctive two-phased recovery for all three measures with the exception of the LDF in 3-month-old rats, which showed only 1 phase. In all animals, LDF recovered fastest (1 hour. 14-month-old rats showed surprisingly faster and greater LDF recovery compared to the younger group, with similar levels of pO2 recovery. However, the ERG in these middle-aged animals did not fully recover after two hours, despite showing no difference in susceptibility to IOP during stress compared to the young group. CONCLUSIONS: Young and middle-aged eyes showed similar susceptibility to IOP elevation in terms of pO2, LDF and ERG. Despite this lack of difference during stress, older eyes did not completely recover function, suggesting a more subtle age-related susceptibility to IOP.

  18. Aspherical Lens Design Using Genetic Algorithm for Reducing Aberrations in Multifocal Artificial Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Chih-Ta Yen

    2015-09-01

    Full Text Available A complex intraocular lens (IOL design involving numerous uncertain variables is proposed. We integrated a genetic algorithm (GA with the commercial optical design software of (CODE V to design a multifocal IOL for the human eye. We mainly used an aspherical lens in the initial state to the crystalline type; therefore, we used the internal human eye model in the software. The proposed optimized algorithm employs a GA method for optimally simulating the focusing function of the human eye; in this method, the thickness and curvature of the anterior lens and the posterior part of the IOL were varied. A comparison of the proposed GA-designed IOLs and those designed using a CODE V built-in optimal algorithm for 550 degrees myopia and 175 degrees astigmatism conditions of the human eye for pupil size 6 mm showed that the proposed IOL design improved the spot size of root mean square (RMS, tangential coma (TCO and modulation transfer function (MTF at a spatial frequency of 30 with a pupil size of 6 mm by approximately 17%, 43% and 35%, respectively. However, the worst performance of spherical aberration (SA was lower than 46%, because the optical design involves a tradeoff between all aberrations. Compared with the traditional CODE V built-in optimal scheme, the proposed IOL design can efficiently improve the critical parameters, namely TCO, RMS, and MTF.

  19. Breakdown of the normal optic nerve head blood-brain barrier following acute elevation of intraocular pressure in experimental animals.

    Science.gov (United States)

    Radius, R L; Anderson, D R

    1980-03-01

    Five hours of elevated intraocular pressure produced evidence of an altered blood-brain barrier at the optic nerve head in 27 of 29 monkey eyes. The change in vascular permeability was documented by fluorescein angiography (18 of 21 eyes), by Evans blue fluorescence microscopy (21 of 23 eyes), or by both methods. Leakage occurred from major blood vessels as well as from microvasculature of the nerve head. In 22 eyes, rapid axonal transport was studied after intravitreal injection of tritiated leucine. In 18 of these 22 eyes, autoradiography demonstrated a local interruption of axonal transport. In 15 eyes examined by all three methods, leakage from microvasculature (as opposed to leakage from the major vessels) was loosely associated with severe and widespread blockade of axonal transport at the lamina cribrosa. Although cause-and-effect relationships are not proved, ischemia may be responsible both for the focal endothelial damage with breakdown of the normal blood-brain barrier and for the local abnormalities of axonal transport.

  20. Effect of elevated intraocular pressure on the thickness changes of cat laminar and prelaminar tissue using optical coherence tomography.

    Science.gov (United States)

    Zhao, Qiuyun; Qian, Xiuqing; Li, Lin; Sun, Weijian; Huang, Shan; Liu, Zhicheng

    2014-01-01

    The aim of this study was to examine shape the changes of the lamina cribrosa (LC) under different intraocular pressures (IOPs) with different periods. Images of the optic nerve head were obtained using enhanced depth imaging spectral domain optical coherence tomography (EDI SD-OCT). After an initial scan of the IOP at native pressure, subsequent scanning was taken when the IOP values reached 40, 60, 80 and 100 mm Hg. Then scans continued with the IOP maintained at 100 mm Hg for 1 hour, 2 hours, 3 hours and 4 hours. The thicknesses of the LC and prelaminar tissue were measured and the curvature of the LC was calculated. Our study found that as IOP increased, the thicknesses of both LC and prelaminar tissue decreased and the thickness variation of the LC correlated significantly with the increases of IOP when IOP was higher than 60 mm Hg. An exponential function was proposed to express the relationship between IOP and the thickness variations of LC and prelaminar tissue. Creep curves of the LC and prelaminar tissue was also obtained using the Prony model. In conclusion, both the thickness of the prelaminar tissue and LC thinned as the IOP elevated. The thickness of the LC also decreased after 4 hours of constant 100 mm Hg pressure.

  1. Changes in the retrobulbar arterial circulation after decrease of the elevated intraocular pressure in men and women with primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2013-01-01

    Full Text Available Introduction. An altered perfusion of the optic nerve head has been proposed as a pathogenic factor of glaucoma. Objective. The aim of this study was to evaluate the changes of the hemodynamic parameters in the retrobulbar arterial circulation after decrease of the elevated intraocular pressure (IOP in women and men with primary open angle glaucoma. Methods. The study included 60 patients (33 males and 27 females older than 50 years, with diagnosed and treated primary open angle glaucoma (77 eyes of 39 patients had increased IOP, >25 mm Hg. They were examined at the Clinic of Eye Diseases (complete ophthalmologic exam and Clinic of Neurology, Clinical Center of Serbia, Belgrade, from December 2009 to December 2010. Imaging of hemodynamic parameters of three retrobulbar arterial vessels: ophthalmic, central retinal and posterior ciliary arteries with color Doppler was performed. Results. Among women, hemodynamic arterial parameter of the peak-systolic velocity was increased in the central retinal artery and decreased in the ophthalmic artery and posterior ciliary arteries; end- diastolic velocity was increased in all three retrobulbar vascular levels; Pourcelot resistivity index was increased, but pulsatility index was decreased in all three vessels. Among men, peak-systolic velocity, end-diastolic velocity and pulsatility index were decreased in all three vessels; resistivity index was increased in the ophthalmic artery, but decreased in the central retinal artery and posterior ciliary arteries. There was a significant change of the ophthalmic artery pulsatility index in women, and the end-diastolic velocity of the ophthalmic artery in men. Conclusion. There was a difference of the retrobulbar arterial circulation between women and men with primary open angle glaucoma after decrease of the elevated intraocular pressure. The role of vascular factors in the supply of the optic disc neuroretinal rim is important.

  2. Elevating bioavailability of curcumin via encapsulation with a novel formulation of artificial oil bodies.

    Science.gov (United States)

    Chang, Ming-Tsung; Tsai, Tong-Rong; Lee, Chun-Yann; Wei, Yu-Sheng; Chen, Ying-Jie; Chen, Chun-Ren; Tzen, Jason T C

    2013-10-09

    Utilization of curcumin has been limited due to its poor oral bioavailability. Oral bioavailability of hydrophobic compounds might be elevated via encapsulation in artificial seed oil bodies. This study aimed to improve oral bioavailability of curcumin via this encapsulation. Unfortunately, curcumin was indissoluble in various seed oils. A mixed dissolvent formula was used to dissolve curcumin, and the admixture was successfully encapsulated in artificial oil bodies stabilized by recombinant sesame caleosin. The artificial oil bodies of relatively small sizes (150 nm) were stably solidified in the forms of powder and tablet. Oral bioavailability of curcumin with or without encapsulation in artificial oil bodies was assessed in Sprague-Dawley male rats. The results showed that encapsulation of curcumin significantly elevated its bioavailability and provided the highest maximum whole blood concentration (Cmax), 37 ± 28 ng/mL, in the experimental animals 45 ± 17 min (t(max)) after oral administration. Relative bioavailability calculated on the basis of the area under the plasma concentration-time curve (AUC) was increased by 47.7 times when curcumin was encapsulated in the artificial oil bodies. This novel formulation of artificial oil bodies seems to possess great potential to encapsulate hydrophobic drugs for oral administration.

  3. Mice Homozygous for a Deletion in the Glaucoma Susceptibility Locus INK4 Show Increased Vulnerability of Retinal Ganglion Cells to Elevated Intraocular Pressure.

    Science.gov (United States)

    Gao, Shan; Jakobs, Tatjana C

    2016-04-01

    A genomic region located on chromosome 9p21 is associated with primary open-angle glaucoma and normal tension glaucoma in genome-wide association studies. The genomic region contains the gene for a long noncoding RNA called CDKN2B-AS, two genes that code for cyclin-dependent kinase inhibitors 2A and 2B (CDKN2A/p16(INK4A) and CDKN2B/p15(INK4B)) and an additional protein (p14(ARF)). We used a transgenic mouse model in which 70 kb of murine chromosome 4, syntenic to human chromosome 9p21, are deleted to study whether this deletion leads to a discernible phenotype in ocular structures implicated in glaucoma. Homozygous mice of this strain were previously reported to show persistent hyperplastic primary vitreous. Fundus photography and optical coherence tomography confirmed that finding but showed no abnormalities for heterozygous mice. Optokinetic response, eletroretinogram, and histology indicated that the heterozygous and mutant retinas were normal functionally and morphologically, whereas glial cells were activated in the retina and optic nerve head of mutant eyes. In quantitative PCR, CDKN2B expression was reduced by approximately 50% in the heterozygous mice and by 90% in the homozygous mice, which suggested that the CDKN2B knock down had no deleterious consequences for the retina under normal conditions. However, compared with wild-type and heterozygous animals, the homozygous mice are more vulnerable to retinal ganglion cell loss in response to elevated intraocular pressure.

  4. 硅油注入后高眼压的治疗策略%Therapy for elevated intraocular pressure after silicone oil tamponade

    Institute of Scientific and Technical Information of China (English)

    张歆; 梁四妥; 杨艳; 赵华; 徐深

    2012-01-01

    Objective To analyze intraocular pressure (IOP) after silicone oil tamponade for one month.Methods This is a retrospective study.There were 46 cases (46 eyes) from 2004 to 2011 registered in our hospital who accepted vitrectomy and silicone oil tamponade,after one month later,who had elevated IOP.We compared the rate of elevated IOP between two types of silicon oil tamponade for one month,as well as the treatment for elevated IOP.x2 test was used to analyze the results.Result The time for light silicon oil removal was three months ( the rate is 68.8% ) after the operation,and after the second surgery the IOP could be normal.And the time for heavy silicon oil removal was two months (the rate is 64.3% ),then the IOP could be normal.The two results had no statistical differences.But the rate of glaucoma surgery after heavy silicone oil tamponade was higher than that of light silicone oil tamponade.And this result had statistical difference.Conclusion The rate of elevated IOP after light or heavy silicone oil tamponade after one month was the same.The rate of glaucoma surgery after heavy silicone oil tamponade was higher than that of light silicone oil tamponade.%目的 回顾性分析轻重硅油注入术后1个月高眼压的发生及其治疗策略.方法 玻切+轻/重硅油注入术后1个月发生高眼压共46例(46眼).对两种硅油注入术后1个月高眼压的发生率进行分析对比,且对高眼压的处理方式进行对比.结果用x2检验进行分析.结果 轻硅油注入术后取油的时机一般在3个月(68.8%)左右,取出后高眼压可以降至正常范围;重硅油在2个月左右取油(64.3%),取出后高眼压可以降至正常范围.二者没有统计学差异.但重硅油注入术后因高眼压行抗青光眼手术的比例较轻硅油者高,差异有统计学意义.结论 轻重硅油注入术后1个月高眼压的发生率没有统计学差异,但重硅油引起的高眼压最终行抗青光眼手术的比例较轻硅油者高.

  5. 优视胶囊对急性高眼压家兔眼压及神经节细胞的影响%Effects of Youshi capsule on the intraocular pressure(IOP) and retinal ganglion cells (RGC) of rabbits under artificial acute intraocular hypertension

    Institute of Scientific and Technical Information of China (English)

    张宗端; 段俊国

    2001-01-01

    目的:观察优视胶囊对急性高眼压兔眼压的影响及对视网膜视神经的保护作用。方法:采用自行设计的上巩膜静脉结扎法建立18只兔眼急性高眼压动物模型,于造模前1周至造模后3天共10天内给予具活血化瘀、开窍明目功效的优视胶囊灌胃,18只造模眼随机分为模型组、低剂量组和高剂量组,每组6眼,与18只正常眼进行对照。实验过程中测量眼压并行视网膜神经节细胞计数。结果:①造模后即可获得平均眼压高于6.83kPa并能持续3天以上的高眼压动物模型,优视胶囊高、低剂量组表现出轻微的降眼压作用。②持续性的高眼压可造成视网膜神经节细胞减少,但高、低剂量组经优视胶囊治疗后高眼压模型眼神经节细胞数高于模型组,提示优视胶囊具有保护或改善急性高眼压后兔眼视网膜神经节细胞的作用。结论:优视胶囊对急性高眼压兔眼视网膜视神经具有保护的作用。%Objective:To observe the effects of Youshi capsule on the intraocular pressure(IOP) and retinal ganglion cells(RGC) of rabbits under artificial acute intraocular hypertension.Methods:We used episcleral veins ligation on rabbit to establish an acute intraocular hypertension animal model devised by ourselves. Between one week before and 3 days after the models were induced, Youshi capsule was irrigated into the stomachs, having the function of promoting blood circulation and removing blood stasis,opening porus and improving vision. 18 model-established eyes were randomly divided into model group, high and low dosage group(6 eyes each group) and compared with other 18 normal eyes. Then examined IOP and counted RGC.Results:①Acute intraocular hypertension animal model was produced just after model was established and its average IOP above 6.83kPa could maintain 3 days. High and low dosage Youshi capsule showed slight effect on the reduction of IOP in intraocluar

  6. Role of prostaglandins and specific place in therapy of bimatoprost in the treatment of elevated intraocular pressure and ocular hypertension: A closer look at the agonist properties of bimatoprost and the prostamides

    Directory of Open Access Journals (Sweden)

    Scott D Smid

    2009-11-01

    Full Text Available Scott D SmidDiscipline of Pharmacology, School of Medical Sciences, Faculty of Health Sciences, University of Adelaide, Adelaide, SA, AustraliaAbstract: Bimatoprost is the only representative of a novel class of prostaglandin ethanolamide (prostamide compounds used therapeutically as an efficacious treatment for glaucoma. The pathways through which bimatoprost works to improve uveoscleral outflow to relieve elevated intraocular pressure are similar to those of the conventional prostaglandins used in glaucoma therapy, with some evidence of a preferential action at the trabecular meshwork. The pharmacology of bimatoprost is however, unclear. Pharmacological evidence supports a specific and distinct receptor-mediated agonist activity of bimatoprost at ‘prostamide’ receptors, which is selective to the prostamides as a class. However, other studies have reported either activity of bimatoprost at additional prostanoid and nonprostanoid receptors, or a conversion of bimatoprost to metabolites with agonist activity at prostaglandin FP receptors in the human eye. The formation of endogenous prostamides has been demonstrated in vivo, by a novel pathway involving the cyclooxygenase-2-mediated conversion of endogenous cannabinoid (endocannabinoid substrates. Irrespective of the pharmacology of bimatoprost and the prostamides in general, further studies are needed to determine the biological role and biochemical pathology of prostamides in the human eye, particularly in glaucoma. Such studies may improve our understanding of uveoscleral flow and may offer new treatments for controlling intraocular pressure.Keywords: bimatoprost, endocannabinoid, glaucoma, prostamides, trabecular meshwork

  7. Exploring the Role of Genetic Algorithms and Artificial Neural Networks for Interpolation of Elevation in Geoinformation Models

    Science.gov (United States)

    Bagheri, H.; Sadjadi, S. Y.; Sadeghian, S.

    2013-09-01

    One of the most significant tools to study many engineering projects is three-dimensional modelling of the Earth that has many applications in the Geospatial Information System (GIS), e.g. creating Digital Train Modelling (DTM). DTM has numerous applications in the fields of sciences, engineering, design and various project administrations. One of the most significant events in DTM technique is the interpolation of elevation to create a continuous surface. There are several methods for interpolation, which have shown many results due to the environmental conditions and input data. The usual methods of interpolation used in this study along with Genetic Algorithms (GA) have been optimised and consisting of polynomials and the Inverse Distance Weighting (IDW) method. In this paper, the Artificial Intelligent (AI) techniques such as GA and Neural Networks (NN) are used on the samples to optimise the interpolation methods and production of Digital Elevation Model (DEM). The aim of entire interpolation methods is to evaluate the accuracy of interpolation methods. Universal interpolation occurs in the entire neighbouring regions can be suggested for larger regions, which can be divided into smaller regions. The results obtained from applying GA and ANN individually, will be compared with the typical method of interpolation for creation of elevations. The resulting had performed that AI methods have a high potential in the interpolation of elevations. Using artificial networks algorithms for the interpolation and optimisation based on the IDW method with GA could be estimated the high precise elevations.

  8. 玻璃体切除联合硅油填充术后高眼压的病因%Cause analysis of intraocular pressure elevation after vitrectomy and silicone oil retinal tamponade

    Institute of Scientific and Technical Information of China (English)

    普建萍; 马嘉; 袁援生

    2013-01-01

    继发性高眼压是硅油填充术后较常见的并发症,其主要原因有:(1)硅油填充过多;(2)硅油乳化;(3)硅油进入前房;(4)硅油的慢性毒性作用;(5)联合其他手术;(6)眼外伤;(7)患者术前眼基础状况;(8)术后用药及术后体位等.本综述对玻璃体切除联合硅油填充术后继发高眼压的病因、治疗、预后等进行回顾性分析.%Secondary high intraocular pressure(IOL) is one of the most common complications after silicone oil tamponade.The mechanisms of elevated IOP secondary to silicone oil tamponade remains complex.Several factors could be involved such as:(1) excessive silicone oil tamponade ; (2) silicone oil emulsification ; (3) diffusion of silicone oil into the anterior chamber; (4) chronic toxic effects of silicone oil; (5) association with an other surgery ; (6) ocular traumatism ; (7) preoperative predisposing factors ;(8) postoperative medication and postoperative body position.This manuscript will review the different causes of IOP elevcotion after vitrectomy and silicone oil retinal tamponade.

  9. Bilateral Primary Intraocular Lymphoma

    Directory of Open Access Journals (Sweden)

    Mehrdad Karimi

    2011-01-01

    Full Text Available Purpose: To report a case of bilateral primary intraocular lymphoma. Case report: A 33-year-old man presented with bilateral blurred vision since two years ago. Examination revealed large keratic precipitates, anterior chamber reaction, posterior subcapsular cataracts, and vitreous infiltration. After a short trial of topical and periocular steroids, diagnostic 25-gauge pars plana vitrectomy was performed and cytologic evaluation of the aspirate confirmed a diagnosis of intraocular lymphoma. The patient was subsequently managed with intravitreal methotrexate in both eyes and responded favorably. Central nervous system workup for lymphoma was negative. Conclusion: Primary intraocular lymphoma should be considered in young adults suffering from chronic recalcitrant panuveitis.

  10. Pseudophakia and intraocular pressure.

    Science.gov (United States)

    Radius, R L; Schultz, K; Sobocinski, K; Schultz, R O; Easom, H

    1984-06-01

    We studied the change in intraocular pressure in 373 consecutive eyes undergoing cataract extraction with intraocular lens implantation between Jan. 1, 1981, and May 31, 1982. There was a mean increase in intraocular pressure of 0.1 mm Hg following this surgery. This increase, however, was not statistically significant (P greater than .5). There was a mean rise in pressure of 0.8 mm Hg in the eyes undergoing intracapsular surgery and a mean fall in pressure of 0.6 mm Hg in the eyes undergoing extracapsular surgery (P less than .05). The change in pressure was unrelated to age, surgeon, or lens type. The results of a separate analysis of 16 eyes with a preoperative diagnosis of glaucoma and eight eyes with ocular hypertension were similar.

  11. Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique.

    Science.gov (United States)

    Kelkar, Aditya; Shah, Rachana; Kelkar, Jai; Kelkar, Shreekant; Arora, Ekta

    2015-01-01

    Sutureless, glueless, scleral fixation of an intraocular lens is a known technique of fixing a lens in the scleral pockets. However, this technique is applied to single-piece and toric lenses instead of 3-piece lenses, allowing the advantage of the use of premium lenses in patients with poor capsular support. Favourable results without complications of pigment dispersion, iris transillumination defects, dysphotopsia, elevated intraocular pressure, intraocular hemorrhage and cystoid macular edema with a well-centered, stable intraocular lens have been observed in the 3-month postoperative period in both cases.

  12. Opaque intraocular lens implantation

    OpenAIRE

    Yusuf IH; Patel CK

    2013-01-01

    Imran H Yusuf, CK Patel The Oxford Eye Hospital, West Wing, John Radcliffe Hospital, Headley Way, Headington, Oxford, United KingdomWe read with great interest the recent article by Lee et al,1 who described their clinical experience with three patients who underwent primary implantation of Morcher (Stuttgart, Germany) occlusive intraocular lenses (IOLs) across a variety of neuro-ophthalmic indications. We hope to offer some further insight into these clinical observations in the context of o...

  13. claw intraocular lens

    OpenAIRE

    Gonnermann, Johannes

    2015-01-01

    There is a wide range of alternative fixation techniques of intraocular lenses in the absence of adequate capsular support, such as angle- or iris-supported anterior chamber lenses and intra- / transsclerally-fixated (suture, fibrin glue, etc.) and iris-supported posterior chamber lenses. All procedures have different advantages and disadvantages depending on the anatomical situation and integrity of the capsular bag complex and the neighboring structures such as the iris, sclera and corneal ...

  14. Phakic Intraocular lens- a review

    OpenAIRE

    Cruz, Francisco Miguel

    2015-01-01

    Introduction: Intraocular refractive procedures with the implantation of a Phakic Intraocular lens have become a safe efficient and predictable alternative for treating high ametropias when the use of corneal photoablative procedures is not possible. The implantation of Phakic intraocular lens preservs the accomodative function,is a reversable refractive procedure, with minimal induction of higher order aberrations compaed with corneal photoablative procedures. Methods: An analytical review o...

  15. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  16. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  17. How to measure intraocular pressure: applanation tonometry

    Directory of Open Access Journals (Sweden)

    Nick Astbury

    2012-01-01

    Full Text Available Unless there is a contraindication (e.g. trauma or corneal ulcer, all adults attending an eye unit should have their intraocular pressure (IOP measured. Many people with glaucoma have no symptoms and do not know they have the condition. All children who have had cataract surgery should also have their IOP measured at every follow-up visit, if possible. Finding glaucoma early allows treatment to be given which will preserve sight. Although elevated IOP is not the only sign of glaucoma, measuring it is simple and quick to do. Applanation tonometry, using a Goldmann tonometer at a slit lamp, is the preferred method (the ‘gold standard’.

  18. Professor Peter Choyce: an early pioneer of intraocular lenses and corneal/refractive surgery.

    Science.gov (United States)

    Pandey, Suresh K; Apple, David J

    2005-06-01

    Professor Peter Choyce, FRCS, DOMS, MS, was one of the pioneers of intraocular lens implant surgery. He developed an interest in artificial lens implantation following cataract surgery, a procedure that was widely criticized by the ophthalmic establishment in the UK, Europe, North America and other countries. Owing to the opposition to the intraocular lenses, Peter Choyce together with Sir Harold Ridley co-founded the International Intraocular Implant Club in 1966, which was responsible for the gradual acceptance of artificial lens implantation. Peter Choyce developed several models of intraocular lens, but did not patent the majority of them. The Choyce Mark IX, manufactured by Rayner Intraocular Lenses, became the first US Food and Drug Administration-approved intraocular lens in 1981. A review of Peter Choyce's record confirms a significant number of original innovations in the field of anterior segment surgery, including many procedures taken for granted today, but not associated with his name. These include early work on both kerato- and intraocular lens-refractive procedures, keratoprosthesis, pioneering paediatric implant procedures and others. Unfortunately his tenacious adherence to anterior chamber lens technology, while in general clinically sound, caused many to question his influence and hence he remained poorly understood even until after his death. He passed away on 8 August 2001 after a long fight with colon cancer. In this article, we provide evidence and elaborate Peter Choyce's accomplishments, which places him as one of the most innovative ophthalmologist in his surgical field in the twentieth century.

  19. The genetics of intraocular pressure.

    Science.gov (United States)

    Ojha, Pallavi; Wiggs, Janey L; Pasquale, Louis R

    2013-01-01

    Glaucoma is a leading cause of irreversible blindness. Intraocular pressure (IOP) is the only modifiable risk factor for glaucoma, yet there is little known about the molecular events that regulate IOP. Genetic and genomic studies have helped identify genes that influence IOP and could lead to the identification of biological pathways that serve as targets for novel pressure-modifying therapies. Genetic linkage studies resulted in the identification of several genes that cause Mendelian (autosomal dominant or autosomal recessive) forms of high-pressure glaucoma, including MYOC. PITX2, FOXC1, and CYP1B1. Classical twin studies suggest that IOP is a heritable trait. More recently, genome-wide association studies (GWAS) have shown that common genetic variants in the GAS7 and TMCO1 genomic regions are associated with elevated IOP. TMCO1 has also been associated with primary open-angle glaucoma in patients with advanced disease. A further study identifying additional genes contributing to IOP will be necessary to fully define the underlying genetic architecture of IOP.

  20. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Science.gov (United States)

    Jordana, M Isabel Canut; Formigó, Daniel Pérez; González, Rodrigo Abreu; Reus, Jeroni Nadal

    2010-01-01

    Aims We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Methods Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Results Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Conclusion Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively. PMID:21151331

  1. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials...

  2. Foldable micro coils for a transponder system measuring intraocular pressure

    Energy Technology Data Exchange (ETDEWEB)

    Ullerich, S.; Schnakenberg, U. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1; Mokwa, W. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1]|[Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany); Boegel, G. vom [Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany)

    2001-07-01

    A foldable transponder system consisting of a chip and a micro coil for measuring intraocular pressure continuously is presented. The system will be integrated in the haptic of a soft artificial intraocular lens. Calculations of planar micro coils with 6 mm and 10.3 mm in diameter show the limits for planar coils with an outer diameter of 6 mm. For the realisation of the transponder system a 20 {mu}m thick coil with an outer diameter of 10.3 mm, an inner diameter of 7.7 mm, 16 turns and a gap of 20 {mu}m between the windings was selected. Measurements show a good agreement between calculated and measured values. Wireless pressure measurements were carried out showing a linear behaviour of the output signal with respect to the applied pressure. (orig.)

  3. Study on Titanium Nitride Film Modified for Intraocular Lens

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective:To study the characteristics of the intraocular lens using ion beam sputtering depositing titanium nitride thin film on the intraocular lens(IOLs).Methods:To deposite titanium nitride thin film on the top of intraocular lens by ion beam sputtering depositing.We analyzed the surface morphology of intraocular lens through SEM and AFM.We detected intraocular lens resolution through the measurement of intraocular lens.Biocompatibility of intraocular lens is preliminary evaluated in this test.Results:T...

  4. Elevator group control dispatch algorithm based on artificial fish-swarm algorithm%基于鱼群算法的电梯群控调度算法

    Institute of Scientific and Technical Information of China (English)

    王瀚韬; 李强; 郑永康

    2013-01-01

    In order to improve the operating efficiency of elevator group control system (EGCS) and aiming at the deficiency in current EGCS scheduling algorithm at home and abroad,an intelligent scheduling algorithm was proposed,the number of people inside the elevator was taken as the scheduling factor,the average passenger waiting time,average riding time and energy consumption were considered.The artificial fish swarm algorithm (AFSA) theory was applied into practical elevator group scheduling problem,the discrete fish swarm algorithm parameters were optimized and the step length was improved in order that the scheduling algorithm was appropriate for the elevator group scheduling.The algorithm first initialized a shoal of fish,in which each fish's present state represented a viable scheduling scheme.Then,it optimized generally the foraging behavior,poly group behavior and the rear-end behavior in space scale after reduction of number scheduling factors in the lift box.Finally,this algorithm was compared with the minimum waiting time scheduling algorithm.The research results indicate that the average waiting time,average riding time and frequency of long-waiting of passengers are significantly reduced.%为了提高电梯群控系统(EGCS)运行效率,针对国内外电梯群控调度算法存在的问题,提出了一种将电梯轿厢内人数作为调度因素,综合考虑乘客平均等待时间、平均乘梯时间、电梯能耗的智能调度算法.将人工鱼群算法理论与实际的电梯群控调度问题相结合,通过对离散鱼群算法参数的优化、步长的改进,使其适用于电梯群控调度.该算法首先初始化一个鱼群,使鱼群中每条人工鱼当前的状态代表一种可行的调度方案,在经轿箱内人数调度因素缩小后的解空间范围内,让鱼群通过其觅食行为、聚群行为和追尾行为进行全局寻优.最后,把该算法与最小等待时间调度算法进行了比较.研究结果表明,乘客的平均

  5. MRI and intraocular tamponade media

    Energy Technology Data Exchange (ETDEWEB)

    Manfre, I. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy)); Fabbri, G. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy)); Avitabile, T. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Biondi, P. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Reibaldi, A. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Pero, G. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy))

    1993-05-01

    Thirteen patients who underwent surgery for retinal detachment and injection of intraocular tamponade media (silicone oil, flurosilicone oil, or perfluoro-carbon liquid) underwent magnetic resonance imaging (MRI), using spin-echo T1- and T2-weighted images. The ophthalmic tamponade media showed different signal intensity, according to their chemical structure. Unlike ophthalmoscopy or ultrasonography, MRI showed no oil-related artefact, making possible recognition of recurrent retinal detachment. (orig.)

  6. An artificial neural network to safely reduce the number of ambulance ECGs transmitted for physician assessment in a system with prehospital detection of ST elevation myocardial infarction

    Directory of Open Access Journals (Sweden)

    Forberg Jakob L

    2012-02-01

    Full Text Available Abstract Background Pre-hospital electrocardiogram (ECG transmission to an expert for interpretation and triage reduces time to acute percutaneous coronary intervention (PCI in patients with ST elevation Myocardial Infarction (STEMI. In order to detect all STEMI patients, the ECG should be transmitted in all cases of suspected acute cardiac ischemia. The aim of this study was to examine the ability of an artificial neural network (ANN to safely reduce the number of ECGs transmitted by identifying patients without STEMI and patients not needing acute PCI. Methods Five hundred and sixty ambulance ECGs transmitted to the coronary care unit (CCU in routine care were prospectively collected. The ECG interpretation by the ANN was compared with the diagnosis (STEMI or not and the need for an acute PCI (or not as determined from the Swedish coronary angiography and angioplasty register. The CCU physician's real time ECG interpretation (STEMI or not and triage decision (acute PCI or not were registered for comparison. Results The ANN sensitivity, specificity, positive and negative predictive values for STEMI was 95%, 68%, 18% and 99%, respectively, and for a need of acute PCI it was 97%, 68%, 17% and 100%. The area under the ANN's receiver operating characteristics curve for STEMI detection was 0.93 (95% CI 0.89-0.96 and for predicting the need of acute PCI 0.94 (95% CI 0.90-0.97. If ECGs where the ANN did not identify a STEMI or a need of acute PCI were theoretically to be withheld from transmission, the number of ECGs sent to the CCU could have been reduced by 64% without missing any case with STEMI or a need of immediate PCI. Conclusions Our ANN had an excellent ability to predict STEMI and the need of acute PCI in ambulance ECGs, and has a potential to safely reduce the number of ECG transmitted to the CCU by almost two thirds.

  7. Overlooked retained intraocular foreign body

    Directory of Open Access Journals (Sweden)

    Adžić-Zečević Antoaneta

    2015-01-01

    Full Text Available Introduction. The most common cause for litigation against ophthalmologists in a trauma case is a missed intraocular foreign body (IOFB. IOFBs cause internal eye damage, but some will come to rest in the posterior segment of the eye. Case report. We presented a 57-year-old male who was referred to the ophthalmologist due to decreased visual acuity in his left eye. Slit lamp examination of his left eye showed no pathological findings. Goldmann contact lens examination showed IOFB which was lying in the vitreous body in the inferior-temporal region. Retinal rupture was noticed at 7 o’clock. The optical coherence tomography (OCT examination was performed and it showed atrophic macular area as well as decreased peripapillar retinal fiber layers thickness. Ultrasound showed the IOFB in vitreous body cavity. History revealed that the patient had an accidental trauma, 48 years ago, when an old bomb from World War II (WWII exploded. Due to the decrease in visual acuity and fibrosis of the vitreous body surgical intervention was performed on his left eye (phacoemulsification with intraocular lens implantation, pars plana vitrectomy and instrumental extraction of foreign body. Conclusion. The intraocular foreign body (IOFB was asymptomatic for 48 years. Symptoms depend on material and localization of the foreign body and the type of injury.

  8. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  9. Spatiotemporal alterations of presynaptic elements in the retina after high intraocular pressure

    Institute of Scientific and Technical Information of China (English)

    Jufang Huang; Lihong Zhou; Hui Wang; Jia Luo; Kun Xiong; Leping Zeng; Dan Chen

    2012-01-01

    A rat model of acute high intraocular pressure was established by injecting saline into the anterior chamber of the left eye. Synaptophysin expression was increased in the inner plexiform layer at 2 hours following injury, and was widely distributed in the outer plexiform layer at 3–7 days, and then decreased to the normal level at 14 days. This suggests that expression of this presynaptic functional protein experienced spatiotemporal alterations after elevation of intraocular pressure. There was no significant change in the fluorescence intensity and distribution pattern for synapse-associated protein 102 following elevated intraocular pressure. Synapse-associated protein 102 immunoreactivity was confined to the outer plexiform layer, while synaptophysin immunoreactivity spread into the outer plexiform layer and the outer nuclear layer at 3 and 7 days following injury. These alterations in presynaptic elements were not accompanied by changes in postsynaptic components.

  10. Effect of pegaptanib sodium 0.3 mg intravitreal injections (Macugen) in intraocular pressure

    DEFF Research Database (Denmark)

    Boyer, David S; Goldbaum, Mauro; Leys, Anita M

    2014-01-01

    OBJECTIVE: To assess the rate of pegaptanib-associated sustained intraocular pressure (IOP) elevation. METHODS: A posthoc analysis was conducted on all IOP measurements, except the immediate 30-min postinjection, from all subjects randomised to pegaptanib 0.3 mg or sham injections continuously in...

  11. Intraocular lens with accommodation capacity

    OpenAIRE

    Dorronsoro, Carlos; Alejandre, Nicolás; Bekesi, Nandor; Marcos, Susana

    2014-01-01

    Intraocular lens with accommodation capacity comprising a first optical member (1) having a dynamic optical power, to which a second optical member (2) with a fixed optical power is affixed, in such a manner that at least a central part of each of one of one of the curved surfaces (2a, 2b) of the second optical member (2) and of at least one of the surfaces (1a, 1b) of the first optical member (1) are in contact with each other, the second optical member (2) and the first optical member (1) p...

  12. Applications of Artificial Intelligence Methods in Elevator Traffic Pattern Recognition%人工智能方法在电梯交通模式识别中的应用

    Institute of Scientific and Technical Information of China (English)

    郑高

    2014-01-01

    电梯交通模式识别是一项重要的工作,其准确性直接影响到电梯群控系统的整体性能。文章论述了近年来人工神经网络、模糊逻辑、支持向量机、粒子群算法等人工智能方法在电梯交通模式识别中的应用,并指出了未来的发展方向。%Elevator traffic pattern recognition is an important work, its accuracy directly affects the overall performance of an elevator group control system. Applications of artificial intelligence methods such as artificial neural network (ANN), fuzzy logic, support vector machine (SVM) and particle swarm optimization (PSO) algorithm in elevator traffic pattern recognition in recent years are discussed in this paper, and the future development direction is pointed out.

  13. Effects of phacoemulsification on the intraocular pressure and corneal endothelial cells of the patients with glaucoma

    Institute of Scientific and Technical Information of China (English)

    Ye Zhao; Zhi-Feng Liu

    2016-01-01

    Objective:To explore the intraocular pressure and corneal endothelial cells integrity changes in cataract phacoemulsification after anti-glaucoma surgery.Methods:Phacoemulsification was performed in 102 patients (118 eyes) with cataract after anti-glaucoma surgery and the intraocular pressure and corneal endothelial cell integrity changes of patients were observed at Day 1 and 3, first week and first month before and after surgery, including central corneal endothelial cell density, average cell area (AVE), cell area of coefficient of variation (CV) and central corneal thickness (CCT).Results:The intraocular pressure was elevated, the central endothelial cell density was reduced, the AVE, the CV and CTT thicken were increased at Day 1 and 3, first week and first month after surgery. The difference compared with preoperative was statistically significant. The intraocular pressure and CTT almost recovered to preoperative levels in 1 month after cataract phacoemulsification and the difference was not statistically significant; while the central endothelial cell density was still decreased and AVE and CV were still increased and the difference of these indexes and the coefficient of the patients was statistically significant compared with before surgery.Conclusions:For the patients with anti-glaucoma after cataract phacoemulsification, intraocular pressure and endothelial cell integrity change was initially observed at Day 1 after surgery, whereas they can almost return to the preoperative level in a month after surgery.

  14. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  15. Vitrectomy combined with intraocular tamponade postoperative intraocular pressure changes%玻璃体切除联合眼内填充术后眼压变化

    Institute of Scientific and Technical Information of China (English)

    吴娜; 张红

    2013-01-01

    Objective To observe the posterior vitrectomy combined with intraocular tamponade in early postoperative intraocular pressure changes and to explore the pathogenesis of early high intraocular pressure. Methods On 119 eyes of 132 patients in Ophthalmological Center of Tianjin Medical University line vitrectomy in patients with clinical data analysis of high intraocular pressure, the diagnostic criteria for non contact tonometer is greater than or equal to 24 mm Hg, analysis of vitrectomy combined with different intraocular tamponade postoperative intraocular high incidence and trend. Resuis In 50 eyes in the occurrence of postoperative early elevated intraocular pressure, incidence rates for37. 88%. The sili-cone oil tamponade group, C2F6group, C3F8Group filling filling and simple phaco group, its early postoperative intraocular high morbidity rates were48% ,41.18% ,57.14% ,11.76% , the group compare (χ2 = 14.395, r =3, P =0.002) .with statistical significance. Conclusion Early postoperative intraocular pressure elevation is posterior vitrectomy postoperative common complications, posterior vitrectomy combined with intraocular inert gas or silicone oil tamponade are increased intraocular hypertension risk factors.%目的 观察后部玻璃体切除(PPV)联合眼内填充物术后早期眼压变化规律并探讨早期高眼压的发病机制.方法 对119例(132只眼)在天津医科大学眼科中心行后部PPV患者的临床资料进行分析,高眼压的诊断标准为非接触式眼压计测量眼压≥24 mm Hg,分析了玻璃体切除联合不同眼内填充物术后高眼压的发病率及变化趋势.结果 有50只眼术后发生早期眼压升高,发病率为37.88%.其中硅油填充组、C2F6填充组、C3F8填充组及单纯玻切组,其术后早期高眼压的发病率分别为48%、41.18%、57.14%、11.76%,各组间比较(x2=14.395,r=3,P=0.002),有统计学意义.结论 术后早期高眼压是后部PPV术后常见的并发症,后部PPV联

  16. Intraocular cilia associated with perforating injury

    Directory of Open Access Journals (Sweden)

    Gopal Lingam

    2000-01-01

    Full Text Available Purpose: To report a case series of penetrating injury complicated by occurrence of intraocular cilia. Methods: Retrospective analysis of charts of 11 eyes of 11 patients with penetrating injury and intraocular cilia, presenting between September 1978 and November 1998. Ten eyes underwent surgery for trauma-related problems such as cataract, vitritis, retinal detachment etc., at which time intraocular cilia were removed. One eye did not have surgery and continues to harbour cilia at the posterior perforation site. Results: Metallic wire was responsible for injury in 6 of 11 eyes with intraocular cilia. Five eyes had significant intraocular inflammation. The cilia were located in the anterior segment in 4 eyes; in the posterior segment in 6 eyes and in both in one eye. At the last follow up, 72.7% had 6/18 or better vision. Poor vision in the rest was due to recurrent retinal detachment (2 eyes and macular scarring (1 eye. Conclusion: Intraocular cilia are more commonly associated with injury by a metallic wire. The presentation and management of an injured eye does not seem to be influenced by the presence of cilia in the eye.

  17. Elevating your elevator talk

    Science.gov (United States)

    An important and often overlooked item that every early career researcher needs to do is compose an elevator talk. The elevator talk, named because the talk should not last longer than an average elevator ride (30 to 60 seconds), is an effective method to present your research and yourself in a clea...

  18. Surface Modification of Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Qi Huang

    2016-01-01

    Full Text Available Objective: This paper aimed to review the current literature on the surface modification of intraocular lenses (IOLs. Data Sources: All articles about surface modification of IOLs published up to 2015 were identified through a literature search on both PubMed and ScienceDirect. Study Selection: The articles on the surface modification of IOLs were included, but those on design modification and surface coating were excluded. Results: Technology of surface modification included plasma, ion beam, layer-by-layer self-assembly, ultraviolet radiation, and ozone. The main molecules introduced into IOLs surface were poly (ethylene glycol, polyhedral oligomeric silsesquioxane, 2-methacryloyloxyethyl phosphorylcholine, TiO 2 , heparin, F-heparin, titanium, titanium nitride, vinyl pyrrolidone, and inhibitors of cytokines. The surface modification either resulted in a more hydrophobic lens, a more hydrophilic lens, or a lens with a hydrophilic anterior and hydrophobic posterior surface. Advances in research regarding surface modification of IOLs had led to a better biocompatibility in both in vitro and animal experiments. Conclusion: The surface modification is an efficient, convenient, economic and promising method to improve the biocompatibility of IOLs.

  19. Drug-Eluting Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Angel Concheiro

    2011-11-01

    Full Text Available Notable advances in materials science and in surgical techniques make the management of cataract by replacement of the opaque crystalline with an intraocular lens (IOL, one of the most cost-effective interventions in current healthcare. The usefulness and safety of IOLs can be enhanced if they are endowed with the ability to load and to sustain drug release in the implantation site. Drug-eluting IOLs can prevent infections and untoward reactions of eye tissues (which lead to opacification and also can act as drug depots for treatment of several other ocular pathologies. Such a myriad of therapeutic possibilities has prompted the design of drug-IOL combination products. Several approaches are under study, namely combination of the IOL with an insert in a single device, soaking in drug solutions, impregnation using supercritical fluids, coating with drug/polymer layers, and covalent grafting of the drug. The advantages/limitations of each technique are discussed in the present review on selected examples. Although more in vivo data are required, the information already available proves the interest of some approaches in ocular therapeutics.

  20. Biomechanics of Schlemm's canal endothelium and intraocular pressure reduction.

    Science.gov (United States)

    Stamer, W Daniel; Braakman, Sietse T; Zhou, Enhua H; Ethier, C Ross; Fredberg, Jeffrey J; Overby, Darryl R; Johnson, Mark

    2015-01-01

    Ocular hypertension in glaucoma develops due to age-related cellular dysfunction in the conventional outflow tract, resulting in increased resistance to aqueous humor outflow. Two cell types, trabecular meshwork (TM) and Schlemm's canal (SC) endothelia, interact in the juxtacanalicular tissue (JCT) region of the conventional outflow tract to regulate outflow resistance. Unlike endothelial cells lining the systemic vasculature, endothelial cells lining the inner wall of SC support a transcellular pressure gradient in the basal to apical direction, thus acting to push the cells off their basal lamina. The resulting biomechanical strain in SC cells is quite large and is likely to be an important determinant of endothelial barrier function, outflow resistance and intraocular pressure. This review summarizes recent work demonstrating how biomechanical properties of SC cells impact glaucoma. SC cells are highly contractile, and such contraction greatly increases cell stiffness. Elevated cell stiffness in glaucoma may reduce the strain experienced by SC cells, decrease the propensity of SC cells to form pores, and thus impair the egress of aqueous humor from the eye. Furthermore, SC cells are sensitive to the stiffness of their local mechanical microenvironment, altering their own cell stiffness and modulating gene expression in response. Significantly, glaucomatous SC cells appear to be hyper-responsive to substrate stiffness. Thus, evidence suggests that targeting the material properties of SC cells will have therapeutic benefits for lowering intraocular pressure in glaucoma.

  1. Triple procedure in posterior segment intraocular foreign body

    Directory of Open Access Journals (Sweden)

    Azad Rajvardhan

    1998-01-01

    Full Text Available Three patients with intraocular foreign bodies and traumatic cataracts underwent single stage pars plana lensectomy with anterior capsule preservation, vitrectomy, removal of the foreign body, and intraocular lens implantation. The preserved anterior capsule permitted support for the placement of an intraocular lens in the posterior chamber in the ciliary sulcus. The procedure enabled early visual rehabilitation. This procedure seems useful in the management of posterior segment intraocular foreign body associated with cataract.

  2. Late opacification of a hydrophilic acrylic intraocular lens

    Directory of Open Access Journals (Sweden)

    Al-Bdour Muawyah

    2008-01-01

    Full Text Available Cataract extraction and intraocular lens implantation is considered to be a safe procedure in most cases. However, the new advances in the surgical technique namely phacoemulsification and hence the increased use of foldable intraocular lenses have given rise to new complications including late opacification of intraocular lenses. In this case we report late opacification of a foldable hydrophilic acrylic intraocular lens and the surgical technique for its exchange.

  3. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    Directory of Open Access Journals (Sweden)

    Emre Güler

    2014-03-01

    Full Text Available Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalmol 2014; 44: 156-7

  4. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    OpenAIRE

    Emre Güler; Aylin Tenlik; Tuba Kara Akyüz

    2014-01-01

    Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalm...

  5. 21 CFR 886.4300 - Intraocular lens guide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens guide. 886.4300 Section 886.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device...

  6. 23-gauge Transconjunctival Sutureless Vitrectomy in Eyes with Posteriorly Dislocated Intraocular Lens after Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Fatih Horozo¤lu

    2011-08-01

    Full Text Available Purpose: To evaluate the outcomes of 23-gauge (23-G transconjunctival sutureless vitrectomy (TSV in eyes with posteriorly dislocated intraocular lens (IOL after cataract surgery. Material and Method: In this retrospective study, we evaluated 6 eyes of 6 consecutive cases with posteriorly dislocated intraocular lens after cataract surgery between April 2007 and November 2010. Visual acuity, intraocular pressure, detailed fundus examination and details of surgery were recorded. Results: The mean age of the patients was 64.7 years and the mean follow-up was 5.5 months (3-12 months. All eyes received 23-G TSV. Dislocated IOL was removed from the vitreous and implanted into ciliary sulcus in 2 eyes (33.3% with polymethylmetacrilate IOL and in 4 eyes (66.7% with 3-piece hydrophilic acrylic IOL. In 5 of the 6 eyes (83.7%, visual acuity improved postoperatively. In one eye (16.7%, elevation of intraocular pressure was observed postoperatively and controlled by topical treatment. Discussion: 23-G TSV surgery may be used in eyes with posteriorly IOLs after cataract surgery. Studies with a larger number of patients would better demonstrate the efficacy of this method. (Turk J Ophthalmol 2011; 41: 213-6

  7. Design of a Test Bench for Intraocular Lens Optical Characterization

    Science.gov (United States)

    Alba-Bueno, Francisco; Vega, Fidel; Millán, María S.

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  8. Design of a Test Bench for Intraocular Lens Optical Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Alba-Bueno, Francisco; Vega, Fidel; Millan, Maria S, E-mail: francisco.alba-bueno@upc.edu, E-mail: fvega@oo.upc.edu, E-mail: millan@oo.upc.edu [Departamento de Optica y Optometria, Universidad Politecnica de Cataluna, C/ Violinista Vellsola 37, 08222 Terrassa (Spain)

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  9. Associations with intraocular pressure across Europe

    DEFF Research Database (Denmark)

    Khawaja, Anthony P; Springelkamp, Henriët; Creuzot-Garcher, Catherine

    2016-01-01

    Raised intraocular pressure (IOP) is the most important risk factor for developing glaucoma, the second commonest cause of blindness globally. Understanding associations with IOP and variations in IOP between countries may teach us about mechanisms underlying glaucoma. We examined cross-sectional...

  10. Intraocular Silicone Oil Masquerading as Terson Syndrome

    Directory of Open Access Journals (Sweden)

    Navid Elmi Sadr

    2016-01-01

    Full Text Available Introduction. Terson syndrome is described as intraocular hemorrhage in association with any type of intracranial hemorrhage and is associated with higher mortality rate and vision loss. Intraocular hemorrhage in Terson syndrome may be diagnosed using computed tomography but there are false positive results. Silicone oil which is widely used for internal tamponade of complicated retinal detachments has high attenuation on computed tomography and hyperintensity on T1-weighted magnetic resonance imaging that can mimic intraocular hemorrhage. This report shows that silicone oil is another origin of false positive results in interpreting CT findings for detecting Terson syndrome. Case Report. A 71-year-old diabetic woman presented with loss of consciousness. Brain computed tomography revealed right cerebellar hemorrhage and ventricular hemorrhage and hyperdensity in vitreous cavity of the left eye that was initially interpreted as vitreous hemorrhage. Terson syndrome was the initial diagnosis but ophthalmoscopic examination and brain MRI showed that the left eye had silicone oil tamponade. Conclusion. Without knowing the history of previous vitreoretinal surgery, CT scan findings of intraocular silicone oil may be interpreted as vitreous hemorrhage. In patients with concomitant intracranial hemorrhage, it can masquerade as Terson syndrome.

  11. Intraocular lens in a fighter aircraft pilot.

    OpenAIRE

    Loewenstein, A; Geyer, O; Biger, Y; Bracha, R; Shochat, I; Lazar, M.

    1991-01-01

    A pseudophakic pilot of the Israeli air force flying an F-15 (Eagle) aircraft was followed up for three years. He experienced about 100 flying hours, 5% of the time under high g stress. The intraocular lens did not dislocate and no complications were observed. It seems that flying high performance fighter aircraft is not contraindicated in pseudophakic pilots.

  12. Closed intraocular microsurgery in ocular trauma.

    Science.gov (United States)

    Kanski, J J

    1978-04-01

    A series of 53 eyes that had suffered severe trauma was treated by closed intraocular microsurgery with vitreous cutters. The cases were divided into three categories: (a) anterior segment reconstruction for traumatic cataracts and post-traumatic pupillary membranes, (b) vitreous haemorrhage with and without retinal detachment, and (c) traumatically dislocated lenses.

  13. Characterizing intraocular tumors with photoacoustic imaging

    Science.gov (United States)

    Xu, Guan; Xue, Yafang; Gursel, Zeynep; Slimani, Naziha; Wang, Xueding; Demirci, Hakan

    2016-03-01

    Intraocular tumors are life-threatening conditions. Long-term mortality from uveal melanoma, which accounts for 80% of primary intraocular tumors, could be as high as 25% depending on the size, ciliary body involvement and extraocular extension. The treatments of intraocular tumors include eye-sparing approaches such as radiotherapy and thermotherapy, and the more aggressive enucleation. The accurate diagnosis of intraocular tumors is thereby critical in the management and follow-up of the patients. The diagnosis of intraocular tumors is usually based on clinical examination with acoustic backscattering based ultrasonography. By analyzing the high frequency fluctuations within the ultrasound (US) signals, microarchitecture information inside the tumor can be characterized. However, US cannot interrogate the histochemical components formulating the microarchitecture. One representative example is the inability of US imaging (and other contemporary imaging modalities as well) in differentiating nevoid and melanoma cells as the two types of cells possesses similar acoustic backscattering properties. Combining optical and US imaging, photoacoustic (PA) measurements encode both the microarchitecture and histochemical component information in biological tissue. This study attempts to characterize ocular tumors by analyzing the high frequency signal components in the multispectral PA images. Ex vivo human eye globes with melanoma and retinoblastoma tumors were scanned using less than 6 mJ per square centimeters laser energy with tunable range of 600-1700 nm. A PA-US parallel imaging system with US probes CL15-7 and L22-14 were used to acquire the high frequency PA signals in real time. Preliminary results show that the proposed method can identify uveal melanoma against retinoblastoma tumors.

  14. Avaliação comparativa do efeito dos colírios de apraclonidina e latanoprost na profilaxia da hipertensão ocular pós capsulotomia com YAG Laser em pacientes não glaucomatosos Profilatic use of apraclonidine and latanoprost to prevent intraocular pressure elevation following Nd:YAG laser posterior capsulotomy

    Directory of Open Access Journals (Sweden)

    Juliane de Freitas S. Paranhos

    1999-10-01

    Full Text Available Objetivo: Comparar a eficácia do latanoprost 0,005% e da apraclonidina 1% na prevenção da hipertensão ocular pós-capsulotomia posterior com YAG laser, em pacientes não- glaucomatosos. Método: Trinta e seis pacientes (36 olhos incluídos foram divididos em três grupos que usaram latanoprost 0,005%, apraclonidina 1% ou placebo. Foram realizadas medidas da pressão ocular antes da instilação de qualquer colírio, 30 minutos após a dilatação, 1 hora e 4 horas após o YAG laser. Resultados: Não houve diferença significativa entre os 3 grupos em relação à idade, pressão ocular inicial e pós-dilatação, assim como em quantidade de energia utilizada. Na primeira hora, tanto para a diferença absoluta quanto para o percentual de alteração da pressão intra-ocular, o grupo da apraclonidina apresentou redução estatisticamente maior em relação ao grupo controle (p 0,05. Na 4a. hora não houve diferença significativa entre os grupos (p > 0,05. As medidas de pressão nos 4 intervalos não apresentaram variação estatisticamente significativa (p > 0,05. A quantidade de energia utilizada não mostrou correlação significativa com o aumento da Po (p > 0,05. Conclusão: A apraclonidina 1% apresentou maior eficácia na profilaxia da hipertensão após capsulotomia posterior com YAG laser quando comparada com latanoprost 0,005%.Purpose: To compare the efficacy of 0.005% latanoprost and 1% apraclonidine in the prevention of an increase of intraocular pressure (IOP after Nd: YAG laser capsulotomy in nonglaucomatous patients. Methods: Thirty-six patients were included and divided in to three groups. Patients received 0.005% latanoprost. 1% apraclonidine or placebo. Four measurements of IOP were made: before instillation of any drug, 30 minutes after cycloplegia, 1 hour and 4 hours after laser. Results: No significant difference was found between the three groups regarding age, initial intraocular pressure, pressure 30 minutes after

  15. Experimental study on cyclosporine A drug delivery system in prevention of posterior capsule opacification after intraocular lens implantation in rabbits

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Objective To study the effect of cyclosporine A drug delivery system (CsA-DDS) on the prevention of posterior capsule opacification (PCO) after experimental intraocular lens implantation in rabbit eyes. Methods Twenty healthy New Zealand white rabbits, whose left eyes and right eyes were used respectively as experiment eyes and controls, were subjected to extracapsular lens extraction and artificial lens implantation. During the operation, CsA-DDS with poly (lactideco-glycolide) as carriers or empty DDS was...

  16. Two-photon absorption induced drug delivery from polymeric intraocular lenses

    Science.gov (United States)

    Hampp, Norbert A.; Kim, Hee-Cheol; Kreiling, Stefan; Hesse, Lutz; Greiner, Andreas

    2003-10-01

    Secondary cataracts are quite often observed after implantation of polymeric intraocular lenses. The reason for this complication is that lens epithelial cells remain in the capsular bag when the natural lens is removed. They begin proliferation and cause secondary cataracts. It is not desireable to add cell toxic agents at the time of the implantation because wound healing is negatively affected. We have developed polymeric intraocular lenses which are equipped with a drug depot which may be released non-invasively through photochemical treatment. In the example presented the drug is 5-fluoruracil (5FU) which is covalently bound to the polymer. Deliberation of 5FU from the polymer is done photochemically. Since light is transmitted permanently through the artificial intraocular lens and wearing of special glasses by the patient should be omitted conventional photochemistry is not a suitable tool for the drug release. The polymer-5FU linkage is designed in a way that it has a high two-photon absorption cross-section. Two-photon absorption is used to selectively release 5FU from the lens. The one-photon reaction is blocked since the cornea does absorb UV light. The principle shown here is not limited to 5FU but may be applied to other drugs also.

  17. Characteristics of Optic Nerve Damage Induced by Chronic Intraocular Hypertension in Rat

    Institute of Scientific and Technical Information of China (English)

    Jiantao Wang; Jian Ge; A.A. Sadun; T.T. Lam

    2004-01-01

    Purpose:To set up the Sharma's chronic intraocular hypertension model and investigate the intraocular pressure (lOP) as well as the optic nerve damage of this model in rat.Methods:The operations of the chronic intraocular hypertension model were performed as described by Sharma in 60 male Lewis albino rats. IOP was measured using the TonoPen XL immediately after surgery and then at 5 day, 2 week or 4 week intervals. Cresyl violet staining of whole-mounted retinas was used to label retinal ganglion cells (RGCs),then RGCs were counted. Paraphenylenediamine (PPD) staining was performed in the semi-thin cross sections of optic nerve of rat, in order to know whether the axons of optic nerve were degenerated or not. Results:There were 47 rats with higher IOP after the episcleral veins cauterized in 60rats. The ratio of elevated IOP was 78.3%. The IOPs were stable in 4 weeks. After cresyl violet staining, the RGCs loss was 11.0% and 11.3% was found in the central and peripheral retina respectively after 2 weeks of increased IOP. After 4 weeks of increased lOP, the loss of RGCs was 17% for the central retina and 24.6% for the peripheral retina. In the retinas without higher IOP, there was no loss of RGCs. PPD staining showed that optic nerve of rat with about 5.3% damage of axons located at the superior temporal region. Region of affected optic nerve 1 mm posterior to the globe by light microscope showed evidence of damaged axons with axonal swelling and myelin debris.Conclusion:Sharma's chronic intraocular hypertension model is a reproducible and effective glaucoma model, which mimics human glaucoma with chronically elevation IOP and induced RGCs loss and damage of optic nerve. Eye Science 2004;20:25-29.

  18. Artificial intelligence

    CERN Document Server

    Hunt, Earl B

    1975-01-01

    Artificial Intelligence provides information pertinent to the fundamental aspects of artificial intelligence. This book presents the basic mathematical and computational approaches to problems in the artificial intelligence field.Organized into four parts encompassing 16 chapters, this book begins with an overview of the various fields of artificial intelligence. This text then attempts to connect artificial intelligence problems to some of the notions of computability and abstract computing devices. Other chapters consider the general notion of computability, with focus on the interaction bet

  19. The Visual Effects of Intraocular Colored Filters

    Directory of Open Access Journals (Sweden)

    Billy R. Hammond

    2012-01-01

    Full Text Available Modern life is associated with a myriad of visual problems, most notably refractive conditions such as myopia. Human ingenuity has addressed such problems using strategies such as spectacle lenses or surgical correction. There are other visual problems, however, that have been present throughout our evolutionary history and are not as easily solved by simply correcting refractive error. These problems include issues like glare disability and discomfort arising from intraocular scatter, photostress with the associated transient loss in vision that arises from short intense light exposures, or the ability to see objects in the distance through a veil of atmospheric haze. One likely biological solution to these more long-standing problems has been the use of colored intraocular filters. Many species, especially diurnal, incorporate chromophores from numerous sources (e.g., often plant pigments called carotenoids into ocular tissues to improve visual performance outdoors. This review summarizes information on the utility of such filters focusing on chromatic filtering by humans.

  20. Intraocular foreign body removal: Case report

    Directory of Open Access Journals (Sweden)

    Kovačević Igor

    2013-01-01

    Full Text Available Introduction. An intraocular foreign body may traumatize the eye mechanically, introduce infection or exert other toxic effects on the intraocular structures. Removal of a metallic intraocular foreign bodies (IOFB use an internal (vitrectomy followed by forceps or internal magnet use or external approach (large electromagnet. Outline of Cases. A 51-year-old man sustained injury of the left eye by a metal foreign body. On admission visual acuity was normal (VOS=1.0 and intraocular tension was within normal limits (TOS=10 mmHg. Nasal scleral entry wound was noticed. Ultrasound of the left eye was done, which confirmed existence of IOFB laying nasally, next to the ciliary body. Extraction of IOFB with a big electric magnet was done. Visual acuity on discharge was the same (VOS=1.0. Another man, aged 30 years, came to the clinic after injury of the left eye by a foreign body. On admission visual acuity was VOS=L+P+ (light and projection, TOS=44 mmHg (higher, traumatic cataract, scleral entry wound, corneal edema, existence of IOFB and initial endophtalmitis. Lensectomia and vitrectomia via pars plana with IOFB extraction were done. Visual acuity on discharge was VOS=5/60 with +6.50 Dsph = 0.3-0.4; TOS=17 mmHg. Conclusion. Magnet removal is indicated in patients when IOFB is laying free in the vitreous body or stopped near the entry wound during injury without other complications. Internal approach - pars plana vitrectomy with forceps removal is used when IOFB is stuck either on the peripheral or posterior part of the retina or if there are some of aforementioned complications.

  1. Environmental standards for intraocular lens implantation.

    Science.gov (United States)

    Crawford, B A; Kaufman, D V

    1984-02-01

    Successful implantation of prosthetic devices depends upon their freedom from postoperative inflammation and infection. Techniques and lessons learned in orthopaedic and other implant surgery should be applied to intraocular lens implantation. The avoidance of contamination by particles and micro-organisms is one essential principle of the surgical procedure. Practical steps are described to reduce both types of contamination. These measures taken together are recommended for adoption as a standard of environmental safety for lens implantation.

  2. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    OpenAIRE

    Elena Bonafonte Marquez; Sergio Bonafonte Royo

    2015-01-01

    We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL) implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for i...

  3. Introduction to the development of intraocular lens

    Science.gov (United States)

    Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2013-08-01

    In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.

  4. [A universal laser for intraocular treatment].

    Science.gov (United States)

    Pomerantzeff, O; Vallat, M; Pankratov, M M; Pflibsen, K P; Schepens, C L

    1988-01-01

    The creation of a single apparatus incorporating the different lasers applicable to intraocular pathology derives from the idea of possessing the means, with one device, of objectively comparing the effects and parameters of various lasers in order to pursue a more precise line of treatment. This has led to our fabrication of the universal intraocular laser. The word universal means the ability of the machine to act on each kind of intraocular tissues with all of the various infrared or other-colored radiations, as well as with different modalities. The unit is transportable. It only requires a source of electric power (110 or 220 V) and includes an independent cooling system. The Nd: YAG laser has selectable operating parameters: pulsed or continuous excitation, Q-switched or mode-locked mode, mirror or fiber optic transmission. It is used also as the basic system of the coloured module. The colour module can provide the three clinically useful radiations: green, red, yellow. The green (532 nm) is obtained by transmission of the I.R. beam brought a birefringent crystal (KTP). Red (650 nm) and yellow (575 nm) come from two incorporated dye lasers excited by the green radiation.

  5. File list: DNS.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.50.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  6. File list: DNS.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.20.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  7. File list: DNS.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.05.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  8. File list: DNS.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.10.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  9. Evaluation of intraocular lens implant location in the eyeball basing on the Purkinje images

    Science.gov (United States)

    Jóźwik, A.; Siedlecki, D.; Zajac, M.

    2012-01-01

    Intraocular lens (IOL) is an artificial implant substituting natural crystalline lens which is non-transparent due to cataract. Incorrect location of the IOL in the eyeball (e.g. its shift or tilt) causes significant deterioration of patient's vision. The analysis of Purkinje images (i.e. reflections from successive refracting surfaces in the eye) enables to determine the real IOL location and thus helps in evaluating the retinal image quality. The experimental setup for Purkinje images recording consists of illuminator, composed of a number of infrared LEDs, telecentric lens and detector (CCD camera). Analysis of mutual position of particular reflections enables to evaluate the lens location in respect to the corneal axis. The actual measurements are realized on artificial eye model, what allows to estimate the precision of the algorithm applied in the calculations. In the future the experimental set-up will be adapted to measure the eyes of real patients.

  10. Artificial Intelligence.

    Science.gov (United States)

    Waltz, David L.

    1982-01-01

    Describes kinds of results achieved by computer programs in artificial intelligence. Topics discussed include heuristic searches, artificial intelligence/psychology, planning program, backward chaining, learning (focusing on Winograd's blocks to explore learning strategies), concept learning, constraint propagation, language understanding…

  11. Clinical Observation of 126 Cases of Sutureless Phacoemulsification with PMMA Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Yanshuang Yan; Zhengxing Mao

    2000-01-01

    Objective: To observe the safety and effect of sutureless phacoemulsification with PMMA intraocular lens (IOL) implantation.Methods: One-hundred and twenty-six cases (126 eyes) of sutureless phacoemulsification with PMMA intraocular lens (IOL) implantation were retrospected and evaluated. The surgeries were performed through a limbal tunnel incision. PMMA IOLs with 5.5mm or 6.0mm in diameter were implanted.Results: The follow-up was 3~20 months. Visual acuity of 0. 5 or better was obtained in 120 cases (95.2%), and that of 1.0 or better was obtained in 89 cases (70. 6% ).Intra-operative complications included posterior capsule rupture in 9 cases (7. 1% ) and iris injury in 7 cases(5.6% ). Postoperative complications included early corneal edema in 96 cases(76.2% ), transient intraocular pressure elevation in 5 cases(4. 3%),remnant of cortex in 1 case and leakage of incision in 1 case. M1 were properly managed with good results.Conclusion: Sutureless phacoemulsification with PMMA IOL implantation is safe even in grass-root hospitals where cataracts are harder.

  12. Intraocular lens power estimation by accurate ray tracing for eyes underwent previous refractive surgeries

    Science.gov (United States)

    Yang, Que; Wang, Shanshan; Wang, Kai; Zhang, Chunyu; Zhang, Lu; Meng, Qingyu; Zhu, Qiudong

    2015-08-01

    For normal eyes without history of any ocular surgery, traditional equations for calculating intraocular lens (IOL) power, such as SRK-T, Holladay, Higis, SRK-II, et al., all were relativley accurate. However, for eyes underwent refractive surgeries, such as LASIK, or eyes diagnosed as keratoconus, these equations may cause significant postoperative refractive error, which may cause poor satisfaction after cataract surgery. Although some methods have been carried out to solve this problem, such as Hagis-L equation[1], or using preoperative data (data before LASIK) to estimate K value[2], no precise equations were available for these eyes. Here, we introduced a novel intraocular lens power estimation method by accurate ray tracing with optical design software ZEMAX. Instead of using traditional regression formula, we adopted the exact measured corneal elevation distribution, central corneal thickness, anterior chamber depth, axial length, and estimated effective lens plane as the input parameters. The calculation of intraocular lens power for a patient with keratoconus and another LASIK postoperative patient met very well with their visual capacity after cataract surgery.

  13. Comparative Evaluation of Handheld Robot-Aided Intraocular Laser Surgery

    Science.gov (United States)

    Yang, Sungwook; MacLachlan, Robert A.; Martel, Joseph N.; Lobes, Louis A.; Riviere, Cameron N.

    2015-01-01

    This paper presents robot-aided intraocular laser surgery using a handheld robot known as Micron. The micromanipulator incorporated in Micron enables visual servoing of a laser probe, while maintaining a constant distance of the tool tip from the retinal surface. The comparative study was conducted with various control methods for evaluation of robot-aided intraocular laser surgery. PMID:27019653

  14. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  15. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    Directory of Open Access Journals (Sweden)

    Elena Bonafonte Marquez

    2015-01-01

    Full Text Available We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for it could be the only sign of secondary glaucoma.

  16. [Drug delivery systems for intraocular applications].

    Science.gov (United States)

    Bourges, J-L; Touchard, E; Kowalczuk, L; Berdugo, M; Thomas-Doyle, A; Bochot, A; Gomez, A; Azan, F; Gurny, R; Behar-Cohen, F

    2007-12-01

    Numerous drug delivery systems (DDSs) can be used as intraocular tools to provide a sustained and calibrated release for a specific drug. Great progress has been made on the design, biocompatibility, bioavailability, and efficacy of DDSs. Although several of them are undergoing clinical trials, a few are already on the market and could be of a routine use in clinical practice. Moreover, miniaturization of the implants makes them less and less traumatic for the eye tissues and some DDSs are now able to target certain cells or tissues specifically. An overview of ocular implants with therapeutic application potentials is provided.

  17. Out-of-the-bag intraocular lens dislocation: outcomes of posterior chamber intraocular lens exchange, risk factors, and prevention

    Institute of Scientific and Technical Information of China (English)

    ZHENG Dan-ying; CHEN Li-na; SUN Yi; SHAO Ying-feng; LIANG Jing-li; LIU Yi-zhi

    2010-01-01

    Background Dislocation of posterior chamber intraocular lens is one of the most common complications of intraocular lens implantation. Lens exchange is an effective solution to this unsatisfactory status. This study was conducted to analyze the possible predisposing factors for out-of-the-bag posterior chamber intraocular lens dislocation and to study the outcomes of lens exchange surgery.Methods Thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation who underwent posterior chamber intraocular lens exchange in Zhongshan Ophthalmic Center of Sun Yat-sen University (Guangdong,China) from January 2003 to October 2009 were included. A 6-month follow-up was completed. The causes for out-of-the-bag intraocular lens dislocation and visual outcomes of posterior chamber intraocular lens exchange were analyzed. The out-of-the-bag intraocular lens dislocation was diagnosed on the basis of the findings from slit-lamp microscope and B-ultrasound. The dislocated intraocular lens was explanted. Reimplantation of a new posterior chamber intraocular lens was performed in each case using standardized surgical procedures.Results In this study, a total of thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation underwent posterior chamber intraocular lens exchange surgery. Causes for out-of-the-bag intraocular lens dislocation included posterior capsule rupture during the initial cataract extraction procedure (23 eyes, 63.8%), trauma (5 eyes,13.9%), neodymium-doped yttrium aluminium garnet (Nd:YAG) laser-induced dislocation (2 eyes, 5.6%), the status after vitrectomy (2 eyes, 5.6%) and unidentifiable etiology (4 eyes, 11.1%). Symptoms of these patients mainly included decrease in visual acuity (17 cases, 47.2%), blurred vision (16 cases, 44.4%), glare (1 case, 2.8%), diplopia (1 case,2.8%), and halo (1 case, 2.8%). Intraocular lens dislocation into the posterior vitreous cavity (29 eyes, 80.5%), anterior chamber (1

  18. Prognostic Factor Analysis of Intraocular Pressure with Neovascular Glaucoma.

    Science.gov (United States)

    Nakano, Satoko; Nakamuro, Takako; Yokoyama, Katsuhiko; Kiyosaki, Kunihiro; Kubota, Toshiaki

    2016-01-01

    Purpose. To perform multivariate analysis for identifying independent predictors of elevated intraocular pressure (IOP) with neovascular glaucoma (NVG), including antivascular endothelial growth factor (VEGF) intravitreal injections. Methods. We retrospectively reviewed 142 NVG patients (181 eyes) with ischemic retinal diseases [proliferative diabetic retinopathy (PDR) in 134 eyes, retinal vein occlusion (RVO) in 29, and ocular ischemic syndrome in 18]. We analyzed age, gender, initial/final LogMAR VA, initial/final IOP, extent of iris and/or angle neovascularization, treatments, preexisting complications, concurrent medications, and follow-up duration. Results. The mean follow-up duration was 23.8 ± 18.8 months. At the final follow-up, 125 (72.3%) eyes had IOP ≤ 21 mmHg. NVG patients with RVO had a higher degree of angle closure and higher IOP. NVG with PDR had better IOP and LogMAR VA. Angle closure had the greatest impact on final IOP. Greater than 90% of patients treated with trabeculectomy with mitomycin C (LEC) had persistent declines in IOP (≤21 mmHg). Stand-alone and combination anti-VEGF therapies were not associated with improved long-term prognosis of IOP. Conclusions. Angle closure was found to have the greatest effect on NVG-IOP prognosis. When target IOP values are not obtained after adequate PRP with or without anti-VEGF, early LEC may improve the prognosis of IOP.

  19. Prognostic Factor Analysis of Intraocular Pressure with Neovascular Glaucoma

    Directory of Open Access Journals (Sweden)

    Satoko Nakano

    2016-01-01

    Full Text Available Purpose. To perform multivariate analysis for identifying independent predictors of elevated intraocular pressure (IOP with neovascular glaucoma (NVG, including antivascular endothelial growth factor (VEGF intravitreal injections. Methods. We retrospectively reviewed 142 NVG patients (181 eyes with ischemic retinal diseases [proliferative diabetic retinopathy (PDR in 134 eyes, retinal vein occlusion (RVO in 29, and ocular ischemic syndrome in 18]. We analyzed age, gender, initial/final LogMAR VA, initial/final IOP, extent of iris and/or angle neovascularization, treatments, preexisting complications, concurrent medications, and follow-up duration. Results. The mean follow-up duration was 23.8 ± 18.8 months. At the final follow-up, 125 (72.3% eyes had IOP ≤ 21 mmHg. NVG patients with RVO had a higher degree of angle closure and higher IOP. NVG with PDR had better IOP and LogMAR VA. Angle closure had the greatest impact on final IOP. Greater than 90% of patients treated with trabeculectomy with mitomycin C (LEC had persistent declines in IOP (≤21 mmHg. Stand-alone and combination anti-VEGF therapies were not associated with improved long-term prognosis of IOP. Conclusions. Angle closure was found to have the greatest effect on NVG-IOP prognosis. When target IOP values are not obtained after adequate PRP with or without anti-VEGF, early LEC may improve the prognosis of IOP.

  20. 不同坡位柳杉人工林夏季土壤动物群落特征%Soil fauna community structure in Cryptomeria fortunei artificial stands at different slope elevations in summer

    Institute of Scientific and Technical Information of China (English)

    肖玖金; 林宏贵; 周鑫; 尤花; 李云; 张健

    2016-01-01

    为研究柳杉Cryptomeria fortunei人工林不同坡位土壤动物群落结构特征,采用手捡法和干湿漏斗法在四川盆周西缘山地3个不同坡位(海拔分别为1088 m,987 m和830 m)的柳杉人工林设置样地(分别为样地Ⅰ,样地Ⅱ和样地Ⅲ)进行土壤动物群落调查。结果显示:试验所采集到的土壤动物平均密度为3.46×104只·m-2,隶属于5门13纲94类,其中,土壤动物密度和类群数均以样地Ⅲ最高,分别为6.53×104只·m-2和66类,以样地Ⅰ最低,分别为1.35×104只·m-2和38类,土壤动物密度和类群数呈现出随坡位高度增加而减少的趋势;从垂直分布来看,各土层土壤动物密度均随着坡位的上升而减少,各样地有大于43%的土壤动物个体分布在0~5 cm土层(凋落物层除外),有大于72%的土壤动物类群分布在凋落物层;除Simpson优势度指数(C)外,土壤动物多样性指数均以样地Ⅲ最高,同时,各样地间土壤动物群落Sorenson相似性系数较Morisita-Horn相似性系数波动更大,表明坡位对柳杉人工林下土壤动物群落各类群的相对数量影响较类群数的影响大。图3表5参20%Soil fauna, an important comp onent of soil ecosystems, plays an important role in decomposition of biological remains, affects soil properties, and enhances material recycling and energy conversion in the soil. Understanding the impacts of slope elevation on soil fauna is essential to achieve sustainable Cryptomeria for-tunei artificial stand management and biodiversity conservation; therefore, an investigation on soil fauna was carried out in Cryptomeria fortunei plantations. Three sample plots were set at three slope elevations (Plot Ⅰ-1 088 m, Plot Ⅱ-987 m, and Plot Ⅲ-830 m). Macrofauna samples (n=3) were picked up by hand in each sampled slope with the area of 50 cm × 50 cm (0.25 m2). After recording the types of soil fauna, the samples were put into

  1. [Iritis with destabilization of the intraocular pressure due to dislocation of a posterior chamber intraocular lens].

    Science.gov (United States)

    Handzel, D M

    2012-04-01

    This report concerns the case of a 67-year-old male patient who underwent uncomplicated phacoemulsification with implantation of a posterior chamber intraocular lens (IOL). After an interval of 2 months the patient developed iritis together with an uncontrollable increase in intraocular pressure. After a detailed examination a dislocated haptic of the IOL was identified as the cause of the symptoms. The dislocation had led to uveitis-glaucoma-hyphema syndrome although no hemorrhage was observed. In addition to this complication the haptic had arroded the zonular complex which made implantation of an anterior chamber lens necessary. Although improvements in operating techniques, lens materials and designs have been made uveitis-glaucoma-hyphema syndrome has to be kept in mind. Surgical intervention is the only therapeutic option.

  2. Lente intra-ocular multifocal difrativa apodizada: resultados Diffractive apodized multifocal intraocular lens: results

    Directory of Open Access Journals (Sweden)

    Virgilio Centurion

    2007-12-01

    Full Text Available OBJETIVO: Mostrar os resultados visuais e refracionais com lente intra-ocular multifocal difrativa apodizada. MÉTODOS: Estudo de 100 olhos de 50 pacientes com catarata, submetidos à facoemulsificação com implante bilateral de lente intra-ocular (LIO multifocal difrativa apodizada. Foi avaliada a acuidade visual binocular sem e com correção para longe e perto, a previsibilidade refracional e a freqüência de uso de óculos. RESULTADOS: A acuidade visual sem correção para longe foi de e " 20/30 em 97,56% dos olhos operados e e" J2 em 100%, sendo que 82% dos pacientes nunca usam óculos e 16% usam de forma esporádica. CONCLUSÃO: A LIO multifocal difrativa apodizada mostrou ser uma opção previsível, reproduzível e segura na correção dos vícios de refração para longe e perto durante a cirurgia da catarata, permitindo elevado índice de independência ao uso de óculos.OBJECTIVE: To show visual and refraction results using multifocal diffractive apodized intraocular lens. METHODS: The study of 100 eyes of 50 patients with cataract, submitted to phacoemulsification with bilateral implant of multifocal diffractive apodized intraocular lens (IOL. Binocular visual acuity was evaluated with and without correction for near and distance, and refraction previsibility and frequency of wearing glasses. RESULTS: Visual acuity without correction for distance was e" 20/30 in 97.56% of eyes operated on and e" J2 in 100%, of these 82% of patients never wear glasses and 16% wear glasses sporadically. CONCLUSION: Multifocal diffractive apodized IOL proved to be a foreseeable option, reproducible and safe in the correction of refraction errors for distance and near during cataract surgery, enabling a high rate of independence from the use of glasses.

  3. MicroRNA profiling in intraocular medulloepitheliomas.

    Directory of Open Access Journals (Sweden)

    Deepak P Edward

    Full Text Available To study the differential expression of microRNA (miRNA profiles between intraocular medulloepithelioma (ME and normal control tissue (CT.Total RNA was extracted from formalin fixed paraffin embedded (FFPE intraocular ME (n=7 and from age matched ciliary body controls (n=8. The clinical history and phenotype was recorded. MiRNA profiles were determined using the Affymetrix GeneChip miRNA Arrays analyzed using expression console 1.3 software. Validation of significantly dysregulated miRNA was confirmed by quantitative real-time PCR. The web-based DNA Intelligent Analysis (DIANA-miRPath v2.0 was used to perform enrichment analysis of differentially expressed (DE miRNA gene targets in Kyoto Encyclopedia of Genes and Genomes (KEGG pathway.The pathologic evaluation revealed one benign (benign non-teratoid, n=1 and six malignant tumors (malignant teratoid, n=2; malignant non-teratoid, n = 4. A total of 88 miRNAs were upregulated and 43 miRNAs were downregulated significantly (P<0.05 in the tumor specimens. Many of these significantly dysregulated miRNAs were known to play various roles in carcinogenesis and tumor behavior. RT-PCR validated three significantly upregulated miRNAs and three significantly downregulated miRNAs namely miR-217, miR-216a, miR-216b, miR-146a, miR-509-3p and miR-211. Many DE miRNAs that were significant in ME tumors showed dysregulation in retinoblastoma, glioblastoma, and precursor, normal and reactive human cartilage. Enriched pathway analysis suggested a significant association of upregulated miRNAs with 15 pathways involved in prion disease and several types of cancer. The pathways involving significantly downregulated miRNAs included the toll-like receptor (TLR (p<4.36E-16 and Nuclear Factor kappa B (NF-κB signaling pathways (p<9.00E-06.We report significantly dysregulated miRNAs in intraocular ME tumors, which exhibited abnormal profiles in other cancers as well such as retinoblastoma and glioblastoma. Pathway analysis

  4. Energy Efficiency of a New Trifocal Intraocular Lens

    Science.gov (United States)

    Vega, F.; Alba-Bueno, F.; Millán, M. S.

    2014-01-01

    The light distribution among the far, intermediate and near foci of a new trifocal intraocular lens (IOL) is experimentally determined, as a function of the pupil size, from image analysis. The concept of focus energy efficiency is introduced because, in addition to the theoretical diffraction efficiency of the focus, it accounts for other factors that are naturally presented in the human eye such as the level of spherical aberration (SA) upon the IOL, light scattering at the diffractive steps or the depth of focus. The trifocal IOL is tested in-vitro in two eye models: the aberration-free ISO model, and a so called modified-ISO one that uses an artificial cornea with positive spherical SA in instead. The SA upon the IOL is measured with a Hartmann-Shack sensor and compared to the values of theoretical eye models. The results show, for large pupils, a notorious reduction of the energy efficiency of the far and near foci of the trifocal IOL due to two facts: the level of SA upon the IOL is larger than the value the lens is able to compensate for and there is significant light scattering at the diffractive steps. On the other hand, the energy efficiency of the intermediate focus for small pupils is enhanced by the contribution of the extended depth of focus of the near and far foci. Thus, while IOLs manufacturers tend to provide just the theoretical diffraction efficiency of the foci to show which would be the performance of the lens in terms of light distribution among the foci, our results put into evidence that this is better described by using the energy efficiency of the foci.

  5. Intraocular lens employed for cataract surgery

    Science.gov (United States)

    Roszkowska, A. M.; Torrisi, L.

    2014-04-01

    The aim of this paper is to illustrate the techniques of cataract surgery with implantation of intraocular lenses and some physical properties of the used materials. The new technology, coupled with extensive experience and the studied cases, permits to increase the standardization and accuracy of the engravings, by reducing the use and handling of surgical instruments inside the eye. At present it is possible to replace the cataract with crystalline lenses based on biopolymers such as PMMA, silicone, acrylic hydrophilic and hydrophobic acrylic. These materials are increasingly able to replace the natural lens and to ensure the fully functional of the eye. The role of femtosecond lasers in cataract surgery, to assist or replace several aspects of the manual cataract surgery, are discussed.

  6. Primary orbital neuroblastoma with intraocular extension

    Directory of Open Access Journals (Sweden)

    Muthukrishnan Vallinayagam

    2015-01-01

    Full Text Available Neuroblastoma is an undifferentiated malignancy of primitive neuroblasts. Neuroblastoma is among the most common solid tumors of childhood. Orbital neuroblastoma is typically a metastatic tumor. In this case report, we describe a 2-year-old child with a rapidly progressing orbital tumor. Computed tomography revealed an orbital mass lesion with extraocular and intraocular components. An incisional biopsy was done, and a histopathological examination showed features suggestive of neuroblastoma. Systemic workup including ultrasonography of the abdomen, chest roentgenogram, whole body computed tomography, and bone scintigraphy showed no evidence of systemic involvement. The diagnosis of primary orbital neuroblastoma was made, and the child was subjected to chemotherapy followed by rapid melting of the tumor. Neuroblastoma should be considered in the differential diagnosis of childhood orbital tumors.

  7. Mechanical properties of intra-ocular lenses

    Science.gov (United States)

    Ehrmann, Klaus; Kim, Eon; Parel, Jean-Marie

    2008-02-01

    Cataract surgery usually involves the replacement of the natural crystalline lens with a rigid or foldable intraocular lens to restore clear vision for the patient. While great efforts have been placed on optimising the shape and optical characteristics of IOLs, little is know about the mechanical properties of these devices and how they interact with the capsular bag once implanted. Mechanical properties measurements were performed on 8 of the most commonly implanted IOLs using a custom build micro tensometer. Measurement data will be presented for the stiffness of the haptic elements, the buckling resistance of foldable IOLs, the dynamic behaviour of the different lens materials and the axial compressibility. The biggest difference between the lens types was found between one-piece and 3-piece lenses with respect to the flexibility of the haptic elements

  8. Artificial blood

    Directory of Open Access Journals (Sweden)

    Sarkar Suman

    2008-01-01

    Full Text Available Artificial blood is a product made to act as a substitute for red blood cells. While true blood serves many different functions, artificial blood is designed for the sole purpose of transporting oxygen and carbon dioxide throughout the body. Depending on the type of artificial blood, it can be produced in different ways using synthetic production, chemical isolation, or recombinant biochemical technology. Development of the first blood substitutes dates back to the early 1600s, and the search for the ideal blood substitute continues. Various manufacturers have products in clinical trials; however, no truly safe and effective artificial blood product is currently marketed. It is anticipated that when an artificial blood product is available, it will have annual sales of over $7.6 billion in the United States alone.

  9. Artificial blood.

    Science.gov (United States)

    Sarkar, Suman

    2008-07-01

    Artificial blood is a product made to act as a substitute for red blood cells. While true blood serves many different functions, artificial blood is designed for the sole purpose of transporting oxygen and carbon dioxide throughout the body. Depending on the type of artificial blood, it can be produced in different ways using synthetic production, chemical isolation, or recombinant biochemical technology. Development of the first blood substitutes dates back to the early 1600s, and the search for the ideal blood substitute continues. Various manufacturers have products in clinical trials; however, no truly safe and effective artificial blood product is currently marketed. It is anticipated that when an artificial blood product is available, it will have annual sales of over $7.6 billion in the United States alone.

  10. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  11. Intraocular pressure in Japanese diabetic patients

    Directory of Open Access Journals (Sweden)

    Matsuoka M

    2012-07-01

    Full Text Available Masato Matsuoka,1 Nahoko Ogata,2 Kayako Matsuyama,1 Tadanobu Yoshikawa,1 Kanji Takahashi31Department of Ophthalmology, Kansai Medical University, Takii Hospital, Osaka, 2Department of Ophthalmology, Nara Medical University, Nara, 3Department of Ophthalmology, Kansai Medical University, Hirakata Hospital, Osaka, JapanBackground: To determine whether the intraocular pressure (IOP in diabetic patients is significantly different from that in nondiabetic patients.Methods: The medical records of all patients who were initially examined in the Department of Ophthalmology, Kansai Medical University, Takii Hospital were reviewed. At the initial examination, patients had a detailed interview and underwent a comprehensive ophthalmic examinations. All patients were over 20 years of age and did not have glaucoma.Results: A total of 703 patients were evaluated. The mean (±standard error IOP of the diabetic patients was 15.5 ± 0.2 mmHg (n = 206, and was significantly higher than the 14.0 ± 0.1 mmHg (n = 497 in the nondiabetic patients (P < 0.0001. The IOP was negatively correlated with age (r = –0.202; P = 0.024 in the diabetic patients and was weakly but significantly correlated with the glycosylated hemoglobin (HbA1c level (r = 0.240; P = 0.015 in the group with diabetic retinopathy.Conclusion: The significantly higher IOP in diabetic patients and positive correlation of IOP with HbA1c levels in patients with diabetic retinopathy indicate that IOP in diabetic patients is higher, especially in those with poor control of diabetes.Keywords: diabetes mellitus, diabetic retinopathy, intraocular pressure, open-angle glaucoma

  12. Patient acceptability of the Tecnis® multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Sood P

    2011-03-01

    Full Text Available Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anterior prolate IOL with a diffractive multifocal lens design. The design aims to minimize spherical aberration and improve range of focus. The purpose of this review is to assess patient acceptability of the Tecnis® multifocal intraocular lens.Keywords: Tecnis®, intraocular lens, multifocal, presbyopia 

  13. Application of Foldable Intraocular Lens in Multiple Types of Cataract

    Institute of Scientific and Technical Information of China (English)

    Songtao Yuan; Qinghuai Liu; Qing Jiang; Nanrong Yuan

    2002-01-01

    Objective: To evaluate the clinical results of implantation of foldable intraocular lens inmultiple types of cataract.Methods: This retrospective study comprised 162 eyes of 148 patients undergoingphacoemulsification and implantation of foldable intraocular lens, some of whom under-went combined pars plana vitrectomy or trabeculectomy or silicone oil removal. Theperiod of follow-up was from 3 months to 17 months.Results: There is slight reaction postoperatively in all cases. The postoperative uncorrectedvisual acuites was from 0. 05 to 1.2, patient with 0.6 or above acuity were 70.98%. Aneodymium: YAG capsulotomy was required in 5 eyes. Posterior capsule ruptured in 1eyes, and a PMMA intraocular lens was implanted in ciliary sulcus. In one eye, a lenswas removed because of recurrence of retina detachment.Conclusions: The application of foldable intraocular lens in multiple types of cataract issafe, and there is a slight postoperative reaction. less complications , and fast visualacuity recovery.

  14. [Intraocular lens implantation in developmental lens disorders in children].

    Science.gov (United States)

    Kanigowska, Krystyna; Grałek, Mirosława; Kepa, Beata; Chipczyńska, Barbara

    2009-01-01

    The pediatric cataract surgery in eyes with developmental disorders, stay with still considerable challenge. At children, the lasting vision development extorts necessity quick settlement of refraction defect formed after operation. The intraocular lens old boy with cataract in microspherophakia and 12 years old boy with cataract in lens with coloboma. One-piece flexible and rigid PMMA intraocular lens was placed with success at posterior chamber without scleral fixations and without using capsular tension ring in this cases. After 3 years of observation there were no decentration or dislocation of intraocular lens in both children. Authors concluded that in some cases posterior chamber intraocular lens implantation despite defective zonular or capsular support, can make up the effective method of surgical treatment without risk of early dislocation.

  15. Aniseikonia for near vision with unilateral aphakia corrected by intraocular lenses.

    Science.gov (United States)

    Ivashina, A I

    1981-11-01

    1. Our methods for calculation of aniseikonia for near vision allow one to determine it in every patient with an intraocular lens. 2. With an eye with an artificial lens there is a correlation between the amount of accommodation used by the phakic eye and aniseikonia changes subject to the distance from the object. Calculations for aniseikonia for near vision in 43 patients showed that with accommodation used by the normal eye aniseikonia was increased by 3.0% to 7.8% as compared with aniseikonia for distance. With accommodation of the phakic eye lacking, aniseikonia for near vision did not differ much from its value for distance. 3. Calculations for aniseikonia for near vision showed the advantage of intraocular lens implantation for obtaining iso-iconia for distance or tolerable aniseikonia not more than 2.5% to 3.0%. 4. For obtaining iso-iconia for near vision it is necessary to correct the phakic eye to switch off its accommodation partially or completely (with emmetropia, correction +2.0D for near vision).

  16. Intraocular nematode with diffuse unilateral subacute neuroretinitis: case report

    OpenAIRE

    Zakariah Sakinah; Said Mariyani; Alwi Azma-Azalina; Yusoff Munira,; Ghani Zulkifli; Zunaina Embong

    2011-01-01

    Abstract Background Live intraocular nematode is a rare occurrence. Nematode can migrate actively within the eye, creating visual symptoms and damaging ocular tissue. Case presentation A 26-year old man presented with painless reduced vision of the left eye for one week duration. It was associated with floaters. Visual acuity on the left eye was hand movement. Anterior segment examination was normal with normal intra-ocular pressure. Fundus examination showed a live nematode lying subretinall...

  17. Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision

    OpenAIRE

    Ladan Espandar; Shameema Sikder; Majid Moshirfar

    2011-01-01

    Ladan Espandar1, Shameema Sikder2, Majid Moshirfar31Department of Ophthalmology, Tulane University, New Orleans, LA, USA; 2Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USA; 3John A Moran Eye Center, University of Utah, Salt Lake City, UT, USAAbstract: Intraocular lens development is driven by higher patient expectations for ideal visual outcomes. The recently US Food and Drug Administration-approved Softec HD™ lens is an aspheric, hydrophilic acrylic intraocular le...

  18. Patient acceptability of the Tecnis® multifocal intraocular lens

    OpenAIRE

    Woodward, Maria; Sood,Priyanka

    2011-01-01

    Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL) designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anter...

  19. Anterior segment intraocular metallic foreign body causing chronic hypopyon uveitis

    OpenAIRE

    Mete, Güler; Turgut, Yılmaz; Osman, Arslanhan; Gülşen, Ülkü; Hakan, Artaş

    2010-01-01

    Intraocular foreign body (IOFB) is a common association of penetrating ocular trauma. Early diagnosis and removal of IOFBs especially if they are metallic is very important to determine further management and the final result of treatment. Missed IOFB may present in different clinical aspects that may limit its detection and symptoms may only become apparent after a prolonged period of time. We report a case of a missed metallic intraocular foreign body in the anterior chamber over a 2-year p...

  20. Artificial intelligence

    CERN Document Server

    Ennals, J R

    1987-01-01

    Artificial Intelligence: State of the Art Report is a two-part report consisting of the invited papers and the analysis. The editor first gives an introduction to the invited papers before presenting each paper and the analysis, and then concludes with the list of references related to the study. The invited papers explore the various aspects of artificial intelligence. The analysis part assesses the major advances in artificial intelligence and provides a balanced analysis of the state of the art in this field. The Bibliography compiles the most important published material on the subject of

  1. Artificial urushi.

    Science.gov (United States)

    Kobayashi, S; Uyama, H; Ikeda, R

    2001-11-19

    A new concept for the design and laccase-catalyzed preparation of "artificial urushi" from new urushiol analogues is described. The curing proceeded under mild reaction conditions to produce the very hard cross-linked film (artificial urushi) with a high gloss surface. A new cross-linkable polyphenol was synthesized by oxidative polymerization of cardanol, a phenol derivative from cashew-nut-shell liquid, by enzyme-related catalysts. The polyphenol was readily cured to produce the film (also artificial urushi) showing excellent dynamic viscoelasticity.

  2. Relation between intraocular pressure and size of transverse sinuses

    Energy Technology Data Exchange (ETDEWEB)

    Kantarci, Mecit; Onbas, Omer; Alper, Fatih; Okur, Adnan [Atatuerk University, Department of Radiology, Medical Faculty, Erzurum (Turkey); Dane, Senol; Gumustekin, Kenan [Atatuerk University, Department of Physiology, Medical Faculty, Erzurum (Turkey); Aslankurt, Murat [Atatuerk University, Department of Ophtalmatology, Medical Faculty, Erzurum (Turkey); Yazici, Ahmet Taylan [Beyoglu Goez Egitim ve Arastirma Hastanesi, Istanbul (Turkey)

    2005-01-01

    There are asymmetries in the sizes of transverse sinus and intraocular pressure. The purpose of this study was to investigate possible relationships between the asymmetry of transverse sinuses in TOF MR venography and intraocular pressures of right and left eyes. In this study, subjects were 63 male and 42 female medical school students, aged 18-21 years (mean{+-}SD; 19.72{+-}0.67 years). Subjects with neurological and ophthalmologic disease, particularly dural sinus thrombosis, myopia, trauma and glaucoma, were excluded the study. Subjects were divided into five groups according to the magnitudes of the right- and left-transverse sinuses in MR venography results. There is a functional relation between intraocular pressures of the right and left eyes and asymmetry of the transverse sinus. If the transverse sinus on one side is larger and its venous drainage is greater, the intraocular pressure of the eye on this side is lower. It can be speculated that the transverse sinus size may be associated with pathogenesis of diseases with increased intraocular pressure such as glaucoma. We aim to determine the relation between the size and drainage of transverse sinuses in TOF MR venography and intraocular pressure in patients with open-angle glaucoma in our next study. (orig.)

  3. Artificial Reefs

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — An artificial reef is a human-made underwater structure, typically built to promote marine life in areas with a generally featureless bottom, control erosion, block...

  4. Artificial Limbs

    Science.gov (United States)

    ... diabetes. They may cause you to need an amputation. Traumatic injuries, including from traffic accidents and military combat Cancer Birth defects If you are missing an arm or leg, an artificial limb can sometimes replace it. The device, which is ...

  5. Natural - synthetic - artificial!

    DEFF Research Database (Denmark)

    Nielsen, Peter E

    2010-01-01

    The terms "natural," "synthetic" and "artificial" are discussed in relation to synthetic and artificial chromosomes and genomes, synthetic and artificial cells and artificial life.......The terms "natural," "synthetic" and "artificial" are discussed in relation to synthetic and artificial chromosomes and genomes, synthetic and artificial cells and artificial life....

  6. Primary Posterior Chamber Intraocular Lens Implantation in Traumatic Cataract With Posterior Capsule Breaks

    Institute of Scientific and Technical Information of China (English)

    YupingZou; WenhuiYang

    1995-01-01

    Background:In patients with incomplete posterior capsule support,posterior chamber intraocular lenses(PC-IOLs)were implanted with both haptics transs-cleral fixation.This causes more damage to the eye and may result in more com-plications,In patients with small posterior breaks,non-fixation or single haptic fixation may be adequate.Methods:Thiry-two consecutive patients of traumatic cataract with posterior capsule breaks caused by penetrating eye trauma were retospected.Posterior chamber intraocular lenses were implanted in all these patients with three tech-niques,ie,without fixation,with single haptic fixation and with both haptics fixation .The selection of the technique was based on the position and size of the posterior capsule.The follow-up period was 21days to 28months(mean,15.2months).Results:Intra-operative problems included ciliary body bleeding(Two patents,6.25%)and enlargement of posterior capsule breaks(2patients,6.25).Postoperative visual acuity was0.5or better(Corrected)in28case(87.5%)and 0.1-0.4in four patients(12.5%),Postoperative complications included hyphema(6eyes,18.8%),transient intraocular pressure elevation(6eyes,18.8%),transient hypotention(7eyes,21.8%).Postoperative IOL position were good except one case of IOL tilt.No pupillary capture or endophthalmitis was found.Conclusions:Not all PC-IOLs have to be fixed by two haptics.In patients with small posterior capsule breaks,PC-IOLmay not be fixed or fixed by only one haptics.Eye Science1995;11:140-142.

  7. Calcification of intraocular implant lens surfaces.

    Science.gov (United States)

    Wu, Wenju; Guan, Xiangying; Tang, Ruikang; Hook, Daniel; Yan, Wenyan; Grobe, George; Nancollas, George H

    2004-02-17

    Calcification of octacalcium phosphate [Ca8H2(PO4)6 x 5H2O, OCP] on differently packaged "Ultem" and "Surefold" intraocular implant lens surfaces has been studied in vitro in solutions supersaturated with respect to OCP at pH = 7.10 and 37 degrees C. No mineral deposition was observed on the lenses packaged in Ultem vials even after treatment with behenic acid, one of the fatty acids identified on explanted lenses. Following treatment with behenic acid, nucleation of OCP occurred on the lenses from Surefold vials, which incorporate silicone gaskets; induction periods preceding calcification were about 6 h. No mineralization was found on the lenses in vials with other gasket materials, including polytetrafluoroethylene, fluorocarbon elastomer, and polypropylene. The results of this study indicate that both silicone and fatty acids such as behenic acid play important roles in inducing the in vivo calcification of OCP on IOL lenses; all of the lens treatment steps were necessary for nucleation induction.

  8. A study of brachytherapy for intraocular tumor

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Yung Hoon; Lee, Dong Han; Ko, Kyung Hwan; Lee, Tae Won; Lee, Sung Koo; Choi, Moon Sik [Korea Cancer Center Hospital of Korea Atomic Energy Research Institute, Seoul (Korea, Republic of)

    1994-12-01

    Our purpose of this study is to perform brachytherapy for intraocular tumor. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere. Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within {+-}10% and distance deviations are within 0.4 mm. Maximum error is -11.3% and 0.8 mm, respectively. 7 figs, 2 tabs, 28 refs. (Author).

  9. Surgical management of intraocular lens dislocations

    Directory of Open Access Journals (Sweden)

    Adem Gul

    2015-10-01

    Full Text Available ABSTRACTPurpose:To report and compare the surgical, visual, and anatomical outcomes following treatment of dislocated intraocular lenses (IOLs.Methods:The medical records of 28 eyes of 28 patients were evaluated. Age, gender, pre-and postoperative best-corrected visual acuity (BCVA, surgical methods, and complications were recorded.Results:Pre-and postoperative BCVA ranged from counting fingers to 20/32 and from counting fingers to 20/25, respectively. Late-onset dislocations were the most frequently observed complication. The most frequent surgical method was IOL repositioning in 15 of 28 patients, followed by IOL exchange in 11 patients, and IOL removal in 2 patients. Only 1 patient required surgical re-intervention with IOL capture.Conclusions:Visual acuity improved following the use of either IOL repositioning or IOL exchange. No superiority of one method over the other was observed. In the present retrospective case series, management of dislocated IOLs with repositioning or exchange of the primary implant conferred comparable surgical and visual outcomes.

  10. The new factors defining variability of circadian’s rhythms of intraocular and perfusion pressure of glaucoma patients

    Directory of Open Access Journals (Sweden)

    N. A. Baranova

    2016-01-01

    Full Text Available Currently, the most scientifically based local risk and progressive factors are elevated levels of intraocular pressure and its instability during the day, caused by local hydromechanical disturbances. However, the other factors affecting the circadian changes of intraocular pressure levels are still evaluated. It was found that light is one of the most important factors affecting the intensity of the cyclical fluctuations of various biological processes, including, and fluctuations of intraocular pressure. At the same time, glaucoma can lead to a variety of sleep disorders, due to a mismatch between cycles «sleep-wake». One if this reason is the death of retinal ganglion cells and their axons. Such damage indirectly lead to a decrease in production of the pigment melanopsin, which is located in the retina. It is not involved in the visual process, but ensures the implementation of circadian rhythms «sleep-wake» and mediated suppression of epiphyseal melatonin. Most likely, melatonin plays a protective role in the occurrence and progression of glaucoma, protecting retinal cells against free radicals and has a direct impact on the intraocular pressure level. Several studies have shown that the circadian change in intraocular pressure levels, and in particular, its substantial reduction, is influenced by melatonin. In this regard, glaucoma is a disease in which the death of retinal cells, including producing melanopsin, a unique opportunity to study violations of cyclic rhythms. Melatonin acts on such established risk factors and progression of glaucoma as hypertension and diabetes. There are published results of the use of melatonin agonists in the experiment and clinical practice. So, in addition to local and systemic hypotensive action, normalizes sleep patients. Data about the melatonin’s effects on the direct and indirect reduction of intraocular pressure, neuroprotective effects and reducing symptoms of depression can

  11. Comparison of Trans-scleral Fixation of PMMA and Foldable Intraocular Lens in Children

    Institute of Scientific and Technical Information of China (English)

    Yuping Zou; Zhende Lin; Bo Feng; Shaozhen Li

    2001-01-01

    Purpose: To observe the difference of the effects of PMMA and foldable intraocular lenses (IOLs) trans-sclerally fixed in pediatric eyes. Methods: Thirty-two children (43 eyes) who had undergone trans-scleral fixation of IOL were retrospected, of whom 5 children were implanted PMMA IOL in both eyes, 6children were implanted PMMA IOL in one eye and foldable IOL in the other eye, 12children were implanted foldable IOL in one eye and 9 chilrden were implanted PMMA IOL in one eye. Mean age was 5.3 years ( range 2.5 ~ 12 years ). Twelve children had traumatic cataract and the others congenital cataract before lens extraction. Results: Foldable group (18 eyes ): Mean follow-up was 12.1 months. Visual acuity (VA): compared with the best corrected VA before IOL fixation, postoperative best corrected VA improved in 16 eyes, remained unchanged in 2 eyes. In 14 eyes, one or two stitches were needed to seal the incision. Complications: Severe anterior chamber reaction was seen in 3 eyes. Intraocular bleeding was found in 3 eyes. IOL decentration was detected in 1 eye. Iris capture of IOL was seen in one eye. PMMA group (25 eyes ):Mean follow-up was 20.3 months. Visual acuity (VA): compared with the best corrected VA before IOL fixation, postoperative best corrected VA improved in 19 eyes,remained unchanged in 5 eyes and got worse in one eye. In 24 eyes, one to three stitches were needed to seal the incision. Complications: Severe anterior chamber reaction was seen in 5 eyes. Intraocular bleeding was found in 4 eyes. IOL decentration was seen in one eye. Iris capture of IOL was seen in 3 eyes. Intraocular pressure elevated in one eye. Conclusion: Our study shows that trans-scleral fixation of IOL is a safe procedure in pediatric eyes. Foldable IOL showed similar effect compared with PMMA IOL in pediatric trans-scleral fixation. Eye Science 2001; 17:61 ~ 64.

  12. [Intraocular Pressure Sensor Based on a Contact Lens].

    Science.gov (United States)

    Guo, Xuhong; Pet, Weihua; Yao, Zhaolin; Chen, Yuanfang; Hu, Xiaohui; Chen, Hongda; Zhu, Jingyuan; Wu, Huijuan

    2016-02-01

    Intraocular pressure detection has a great significance for understanding the status of eye health, prevention and treatment of diseases such as glaucoma. Traditional intraocular pressure detection needs to be held in the hospital. It is not only time-consuming to doctors and patients, but also difficult to achieve 24 hour-continuous detection. Microminiaturization of the intraocular pressure sensor and wearing it as a contact lens, which is convenient, comfortable and noninvasive, can solve this problem because the soft contact lens with an embedded micro fabricated strain gauge allows the measurement of changes in corneal curvature to correlate to variations of intraocular pressure. We fabricated a strain gauge using micro-electron mechanical systems, and integrated with the contact lens made of polydimethylsiloxane (PDMS) using injection molding. The experimental results showed that the sensitivity was 100. 7 µV/µm. When attached to the corneal surface, the average sensitivity of sensor response of intraocular pressure can be 125.8 µV/mm Hg under the ideal condition.

  13. Effects of 2-alkynyladenosine derivatives on intraocular pressure in rabbits.

    Science.gov (United States)

    Konno, Takashi; Ohnuma, Shin-ya; Uemoto, Kazuhiro; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Endo, Kazuki; Hosokawa, Tomokazu; Nakahata, Norimichi

    2004-02-23

    We evaluated the activities of 2-alkynyladenosine derivatives, relatively selective adenosine A2 receptor agonists, in the intraocular pressure regulation in rabbits. An adenosine A2 receptor agonist 2-[p-(2-carboxyethyl)phenylethylamino]-5'-N-ethylcarboxamidoadenosine (CGS-21680) decreased intraocular pressure, while another A2 receptor agonist 2-(phenylamino)adenosine transiently increased it. The first group of 2-alkynyladenosine derivatives (1-hexyn-1-yl derivatives) caused a transient increase followed by decrease in intraocular pressure, while the second group (1-octyn-1-yl and 6-cyano-1-hexyn-1-yl derivatives) only decreased it. The second group is also effective in the ocular hypertensive models induced by water-loading and alpha-chymotrypsin. The outflow facility was increased by a 1-octyn-1-yl derivative. Both increase and decrease in intraocular pressure induced by 2-alkynyladenosine derivatives were inhibited by an adenosine A2 receptor antagonist 3,7-dimethyl-1-propargylxanthine, but not by an adenosine A1 receptor antagonist 8-cyclopentyl-1,3-dipropyl xanthine. These findings suggest that 2-alkynyladenosine derivatives may affect intraocular pressure via adenosine A2 receptor, and 2-alkynyladenosine derivative-induced ocular hypotension is due to the increase of outflow facility.

  14. Artificial Intelligence

    CERN Document Server

    Warwick, Kevin

    2011-01-01

    if AI is outside your field, or you know something of the subject and would like to know more then Artificial Intelligence: The Basics is a brilliant primer.' - Nick Smith, Engineering and Technology Magazine November 2011 Artificial Intelligence: The Basics is a concise and cutting-edge introduction to the fast moving world of AI. The author Kevin Warwick, a pioneer in the field, examines issues of what it means to be man or machine and looks at advances in robotics which have blurred the boundaries. Topics covered include: how intelligence can be defined whether machines can 'think' sensory

  15. Artificial sweeteners

    DEFF Research Database (Denmark)

    Raben, Anne Birgitte; Richelsen, Bjørn

    2012-01-01

    Artificial sweeteners can be a helpful tool to reduce energy intake and body weight and thereby risk for diabetes and cardiovascular diseases (CVD). Considering the prevailing diabesity (obesity and diabetes) epidemic, this can, therefore, be an important alternative to natural, calorie-containin......Artificial sweeteners can be a helpful tool to reduce energy intake and body weight and thereby risk for diabetes and cardiovascular diseases (CVD). Considering the prevailing diabesity (obesity and diabetes) epidemic, this can, therefore, be an important alternative to natural, calorie...

  16. New trends in intraocular lens imaging

    Science.gov (United States)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the

  17. Epithelial Downgrowth after Intraocular Surgery Treated with Intracameral 5-Fluorouracil

    Directory of Open Access Journals (Sweden)

    Nina Ni

    2015-01-01

    Full Text Available Purpose. To present the clinical and histopathologic correlation of two cases of epithelial downgrowth (EDG after prior intraocular surgery. Methods. Observational case reports. Results. We present two cases of EDG occurring after intraocular surgery. In both cases, after two anterior chamber injections of 5-fluorouracil (5FU, the area of EDG initially regressed. In Case 1, a limited area of EDG eventually recurred, and penetrating keratoplasty with cryotherapy was curative. In Case 2, subsequent corneal edema required Descemet-stripping automated endothelial keratoplasty, and the patient remained clinically free of EDG without further treatment. Conclusion. Intracameral 5FU may have a role in the treatment of EDG after intraocular surgery, though its precise utilization and impact remain to be defined.

  18. Penetrating Scleral Injury with Intraocular Foreign Body. A Case Report

    Directory of Open Access Journals (Sweden)

    Anay Martínez Díaz

    2014-04-01

    Full Text Available Ocular trauma is a health problem in the world today and a common cause of visual impairment leading to severe sequelae and psychological disorders. The case of a 46-year-old male patient who attended the Ophthalmology emergency services of the Dr. Gustavo Aldereguía Lima University General Hospital of Cienfuegos, recounting that while hammering iron on iron he felt that something entered his right eye, is presented. He suffered from pain, tearing, red eye and blurred vision. A penetrating scleral injury with an intraocular foreign body was diagnosed. Its study was conducted through biomicroscopy, orbital x-ray and ocular ultrasound. Surgical treatment by extracapsular lens extraction with intraocular lens implantation was performed using Blumenthal technique and pars plana approach for removal of the intraocular foreign body.

  19. File list: InP.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Oth.05.AllAg.Lenses,_Intraocular mm9 Input control Others Lenses, Intraocular S...RX957681,SRX957691,SRX957693 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  20. File list: Pol.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.05.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  1. File list: Oth.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.10.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  2. File list: Unc.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Oth.20.AllAg.Lenses,_Intraocular mm9 Unclassified Others Lenses, Intraocular SR...X1127448 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  3. File list: InP.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Oth.10.AllAg.Lenses,_Intraocular mm9 Input control Others Lenses, Intraocular S...RX957681,SRX957691,SRX957693 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  4. File list: Oth.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.05.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  5. File list: Pol.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.10.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  6. File list: Unc.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Oth.50.AllAg.Lenses,_Intraocular mm9 Unclassified Others Lenses, Intraocular SR...X1127448 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  7. File list: His.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Oth.50.AllAg.Lenses,_Intraocular mm9 Histone Others Lenses, Intraocular SRX9576...85,SRX957687,SRX957683,SRX957695 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  8. File list: Unc.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Oth.05.AllAg.Lenses,_Intraocular mm9 Unclassified Others Lenses, Intraocular SR...X1127448 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  9. File list: Pol.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.50.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  10. File list: NoD.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.10.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  11. File list: NoD.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.20.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  12. File list: Pol.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.20.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  13. File list: Oth.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.20.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  14. File list: His.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Oth.10.AllAg.Lenses,_Intraocular mm9 Histone Others Lenses, Intraocular SRX9576...85,SRX957687,SRX957695,SRX957683 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  15. File list: NoD.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.50.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  16. File list: NoD.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.05.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  17. File list: Oth.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.50.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  18. File list: His.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Oth.20.AllAg.Lenses,_Intraocular mm9 Histone Others Lenses, Intraocular SRX9576...85,SRX957687,SRX957695,SRX957683 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  19. File list: InP.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Oth.20.AllAg.Lenses,_Intraocular mm9 Input control Others Lenses, Intraocular S...RX957681,SRX957691,SRX957693 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  20. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-08-01

    Full Text Available Mun Yueh Faria,1–3 Nuno Pinto Ferreira,1–3 Joana Medeiros Pinto,1–3 David Cordeiro Sousa,1–3 Ines Leal,1–3 Eliana Neto,1–3 Carlos Marques-Neves1–3 1Centro de Estudos da Visão, Universidade de Lisboa, 2Department of Ophthalmology, Hospital de Santa Maria, 3Faculty of Medicine, University of Lisbon, Lisbon, Portugal Background: Nowadays, dislocated intraocular lenses (IOLs and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL.Methods: This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth.Results: The mean follow-up was 23 months (range: 6–48 months. The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1 retinal detachment was found in one patient, 2 corneal edema was found in three patients, 3 high intraocular pressure was observed in

  1. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Science.gov (United States)

    Faria, Mun Yueh; Ferreira, Nuno Pinto; Pinto, Joana Medeiros; Sousa, David Cordeiro; Leal, Ines; Neto, Eliana; Marques-Neves, Carlos

    2016-01-01

    Background Nowadays, dislocated intraocular lenses (IOLs) and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL) are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL. Methods This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth. Results The mean follow-up was 23 months (range: 6–48 months). The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1) retinal detachment was found in one patient, 2) corneal edema was found in three patients, 3) high intraocular pressure was observed in twelve patients, 4) subluxation of the IOL was observed in one patient, and 5) macular edema was found in three eyes. Conclusion The results demonstrate that retropupillary ICIOL is an easy and effective method for the correction of aphakia in patients not receiving capsule support. The safety of this procedure must be interpreted in the context

  2. Comparison of shape recovery ratios in various intraocular lens haptics.

    Science.gov (United States)

    Kimura, W; Kimura, T; Sawada, T; Kikuchi, T; Toda, H; Yamada, Y; Nagai, H

    1992-11-01

    Since understanding the mechanical properties of intraocular lens (IOL) haptic materials can minimize decentration after surgery, we have examined shape recovery ratios of various intraocular lens haptics (polypropylene [PP], polyvinylidene fluoride [PVDF], extruded poly(methyl methacrylate) [PMMA]) currently on the market under conditions that approximate clinical use. The results using various Ascon lens-holding forceps and compression tests, during which the lenses were held in a cylindrical holder for seven days, one month, and three months, indicated that PVDF haptics had better shape recovery capability than PP and extruded three-piece PMMA haptics.

  3. Polyvinylidene Flouride Polymer Applied in an Intraocular Pressure Sensor

    Science.gov (United States)

    González Morán, Carlos Omar; González Ballesteros, Rubén; Rodríguez Guzmán, Maria Dolores Alicia; Suaste Gómez, Ernesto

    2005-06-01

    An indentation intraocular pressure sensor (IIOPS) was designed and manufactured. It is based on piezoelectric polyvinylidene fluoride (PVDF) films. This sensor will help in the detection and diagnosis of intraocular pressure (IOP) in eye diseases like glaucoma. The pressure in the normal aqueous and vitreous phases is, on average, 15.5 mmHg and up of 21 mmHg when glaucoma exists. The proposed IIOPS offers a measurement range from 10-29 mmHg with a resolution of 1 mmHg and an accuracy of ± 0.025.

  4. The control of aniseikonia after intraocular lens implantation.

    Science.gov (United States)

    Hillman, J S; Hawkswell, A

    1985-01-01

    This paper reports a study of postoperative refraction and eikonometry of 50 patients who had unilateral cataract extraction with implantation of a pupil-supported intraocular lens. The mean postoperative aniseikonia (+/- SD) was 1.97 (+/- 1.82). A statistically significant relationship was shown between anisometropia and aniseikonia. Despite aniseikonia of up to 7.8 per cent there were no diplopia problems as the visual system exhibits a high degree of tolerance. It is concluded that aniseikonia can be controlled to within clinically acceptable limits by the simple calculation of intraocular lens power for isometropia.

  5. USE OF PRESERVATIVE CONTAINING VS PRESERVATIVE FREE INTRAOCULAR STEROID DURING VITRECTOMY

    Directory of Open Access Journals (Sweden)

    Nayana

    2014-12-01

    Full Text Available Triamcinolone is a corticosteroid that is used to treat many ophthalmic diseases . Recently, its use has been advocated to aid in visualization of transparent tissue in ophthalmic surgery. It can be used in anterior segment surgery to help manage vitreous loss during complicated cataract surgery. It has been used to visualize the posterior cortical vitreous during pars plana vitrectomy. In addition, it can be useful in the visualization and peeling of the internal limiting membrane. Triamcinolone has been advocated in surgical repair of proliferative vitreoretinopathy both for its visualizing properties and its anti-inflammatory properties. Overall, triamcinolone use in surgery is safe with low incidence of complications including elevated intraocular pressure, cataract and endophthalmitis.

  6. Artificial ribonucleases.

    Science.gov (United States)

    Morrow, J R

    1994-01-01

    Many inorganic and organic compounds promote the reactions catalyzed by RNase A. Both the transesterification step, where a 2',3'-cyclic phosphate is formed with concomitant cleavage of RNA, and the hydrolysis step, where the 2',3'-cyclic phosphate is converted to a phosphate monoester, may be mimicked with compounds that are readily synthesized in the laboratory. Electrophilic activation of the phosphate ester and charge neutralization are generally important means by which artificial RNases promote phosphate diester displacement reactions. Several artificial RNases operate by a bifunctional general acid/general base mechanism, as does RNase A. Provision of an intramolecular nucleophile appears to be an important pathway for metal complex promoted phosphate diester hydrolysis. In contrast to the successful design of compounds that promote the reactions catalyzed by RNase A, there are no artificial nucleases to date that will cleave the 3' P-O bond of RNA or hydrolyze an oligonucleotide of DNA. Artificial RNases based on both metal complexes and organic compounds have been described. Metal complexes may be particularly effective catalysts for both transesterification and hydrolysis reactions of phosphate diesters. Under physiological conditions (37 degrees C and neutral pH), several metal complexes catalyze the transesterification of RNA. Future work should involve the development of metal complexes which are inert to metal ion release but which maintain open coordination sites for catalytic activity. The design of compounds containing multiple amine or imidazole groups that may demonstrate bifunctional catalysis is a promising route to new artificial RNases. Further design of these compounds and careful placement of catalytic groups may yield new RNase mimics that operate under physiological conditions. The attachment of artificial RNases to recognition agents such as oligodeoxynucleotides to create new sequence-specific endoribonucleases is an exciting field of

  7. Intraocular lens alignment from an en face optical coherence tomography image Purkinje-like method

    Science.gov (United States)

    Sun, Mengchan; de Castro, Alberto; Ortiz, Sergio; Perez-Merino, Pablo; Birkenfeld, Judith; Marcos, Susana

    2014-06-01

    Measurement of intraocular lens (IOL) alignment implanted in patients in cataract surgery is important to understand their optical performance. We present a method to estimate tilt and decentration of IOLs based on optical coherence tomography (OCT) images. En face OCT images show Purkinje-like images that correspond to the specular reflections from the corneal and IOL surfaces. Unlike in standard Purkinje-imaging, the tomographic nature of OCT allows unequivocal association of the reflection with the corresponding surface. The locations of the Purkinje-like images are linear combinations of IOL tilt, IOL decentration, and eye rotation. The weighting coefficients depend on the individual anterior segment geometry, obtained from the same OCT datasets. The methodology was demonstrated on an artificial model eye with set amounts of lens tilt and decentration and five pseudophakic eyes. Measured tilt and decentration in the artificial eye differed by 3.7% and 0.9%, respectively, from nominal values. In patients, average IOL tilt and decentration from Purkinje were 3.30±4.68 deg and 0.16±0.16 mm, respectively, and differed on average by 0.5 deg and 0.09 mm, respectively, from direct measurements on distortion-corrected OCT images. Purkinje-based methodology from anterior segment en face OCT imaging provided, therefore, reliable measurements of IOL tilt and decentration.

  8. Artificial Intelligence.

    Science.gov (United States)

    Lawrence, David R; Palacios-González, César; Harris, John

    2016-04-01

    It seems natural to think that the same prudential and ethical reasons for mutual respect and tolerance that one has vis-à-vis other human persons would hold toward newly encountered paradigmatic but nonhuman biological persons. One also tends to think that they would have similar reasons for treating we humans as creatures that count morally in our own right. This line of thought transcends biological boundaries-namely, with regard to artificially (super)intelligent persons-but is this a safe assumption? The issue concerns ultimate moral significance: the significance possessed by human persons, persons from other planets, and hypothetical nonorganic persons in the form of artificial intelligence (AI). This article investigates why our possible relations to AI persons could be more complicated than they first might appear, given that they might possess a radically different nature to us, to the point that civilized or peaceful coexistence in a determinate geographical space could be impossible to achieve.

  9. Artificial blood.

    OpenAIRE

    1983-01-01

    #Blood substitutes have been developed for almost a century. The various type of artificial blood was continuously available on the market. The theme of this report is to identify the best substitute in emergency situation for some patients and science students. The definition of best is given; thus, as the vital part of the report, the comparison between them is described and discussed. Modified hemoglobin, bovine-based hemoglobin and PFCs are three basic types. In terms of the perfor...

  10. Artificial vision.

    Science.gov (United States)

    Zarbin, M; Montemagno, C; Leary, J; Ritch, R

    2011-09-01

    A number treatment options are emerging for patients with retinal degenerative disease, including gene therapy, trophic factor therapy, visual cycle inhibitors (e.g., for patients with Stargardt disease and allied conditions), and cell transplantation. A radically different approach, which will augment but not replace these options, is termed neural prosthetics ("artificial vision"). Although rewiring of inner retinal circuits and inner retinal neuronal degeneration occur in association with photoreceptor degeneration in retinitis pigmentosa (RP), it is possible to create visually useful percepts by stimulating retinal ganglion cells electrically. This fact has lead to the development of techniques to induce photosensitivity in cells that are not light sensitive normally as well as to the development of the bionic retina. Advances in artificial vision continue at a robust pace. These advances are based on the use of molecular engineering and nanotechnology to render cells light-sensitive, to target ion channels to the appropriate cell type (e.g., bipolar cell) and/or cell region (e.g., dendritic tree vs. soma), and on sophisticated image processing algorithms that take advantage of our knowledge of signal processing in the retina. Combined with advances in gene therapy, pathway-based therapy, and cell-based therapy, "artificial vision" technologies create a powerful armamentarium with which ophthalmologists will be able to treat blindness in patients who have a variety of degenerative retinal diseases.

  11. Effects of angiotensin, vasopressin and atrial natriuretic peptide on intraocular pressure in anesthetized rats

    Science.gov (United States)

    Palm, D. E.; Shue, S. G.; Keil, L. C.; Balaban, C. D.; Severs, W. B.

    1995-01-01

    The effects of atrial natriuretic peptide (ANP), vasopressin (AVP) and angiotensin (ANG) on blood and intraocular pressures of pentobarbital anesthetized rats were evaluated following intravenous, intracerebroventricular or anterior chamber routes of administration. Central injections did not affect intraocular pressure. Equipressor intravenous infusions of ANG raised, whereas AVP decreased, intraocular pressure. Direct infusions of a balanced salt solution (0.175 microliter/min) raised intraocular pressure between 30 and 60 min. Adding ANG or ANP slightly reduced this solvent effect but AVP was markedly inhibitory. An AVP-V1 receptor antagonist reversed the blunting of the solvent-induced rise by the peptide, indicating receptor specificity. Acetazolamide pretreatment lowered intraocular pressure, but the solvent-induced rise in intraocular pressure and inhibition by AVP still occurred without altering the temporal pattern. Thus, these effects appear unrelated to aqueous humor synthesis rate. The data support the possibility of intraocular pressure regulation by peptides acting from the blood and aqueous humor.

  12. Intraocular lens explantation or exchange: indications, postoperative interventions, and outcomes

    Directory of Open Access Journals (Sweden)

    Refik Oltulu

    2015-06-01

    Full Text Available ABSTRACT Purpose: To analyze the indications for explantation or exchange of intraocular lenses (IOLs, which were originally implanted for the correction of aphakia during cataract extraction. Methods: All cases that involved intraocular lens explantation or exchange in one institution between January 2008 and December 2014 were analyzed retrospectively. Results: In total, 93 eyes of 93 patients were analyzed. The median time interval between implantation and explantation of the anterior chamber intraocular lenses (AC IOL and posterior chamber intraocular lenses (PC IOL was 83.40 ± 83.14 months (range: 1-276 months and 55.14 ± 39.25 months (range: 1-168 months, respectively. Pseudophakic bullous keratopathy (17 eyes, 38.6% and persistent iritis (12 eyes, 27.8% in the AC IOL group and dislocation or decentration (30 eyes, 61.2% and incorrect IOL power (nine eyes, 18.4% in the PC IOL group were the most common indications for explantation of IOLs. The mean logMAR best corrected visual acuity (BCVA improved significantly from 1.30 preoperatively to 0.62 postoperatively in the PC IOL group (p<0.001 but did not improve significantly in the AC IOL group (p=0.186. Conclusions: The primary indication for IOL explantation or exchange was pseudophakic bullous keratopathy in the AC IOL group and was dislocation or decentration in the PC IOL group. PC IOL explantation or exchange is safe and improves visual acuity.

  13. Secondary implantation of a double intraocular lens after penetrating keratoplasty.

    Science.gov (United States)

    Gayton, J L

    1998-02-01

    Penetrating keratoplasty (PKP) patients often have severe, visually disabling refractive errors. Astigmatism can be addressed by refractive surgery; however, correcting hyperopia is more problematic. Although pseudophakic PKP patients can have a lens exchange, it can be traumatic in this population. In this pseudophakic PKP patient, I added a second posterior chamber intraocular lens, correcting the hyperopia and resolving visual complaints.

  14. Development of a ciliary muscle-driven accommodating intraocular lens

    NARCIS (Netherlands)

    Hermans, Erik A.; Terwee, Thom T.; Koopmans, Steven A.; Dubbelman, Michiel; van der Heijde, Rob G. L.; Heethaar, Rob M.

    2008-01-01

    PURPOSE: To develop a ciliary muscle-driven accommodating intraocular lens (IOL) that has a large and predictable range of variable power as a step toward spectacle independence. SETTING: Department of Physics and Medical Technology, VU University Medical Center, Amsterdam, The Netherlands. METHODS:

  15. Unexplained heterochromia. Intraocular foreign body demonstrated by computed tomography.

    Science.gov (United States)

    Barr, C C; Vine, A K; Martonyi, C L

    1984-01-01

    Standard radiographic techniques are often inadequate in demonstrating the presence and location of intraocular foreign bodies. Computerized axial tomography was used to confirm the presence of a metallic foreign body in a patient with heterochromia iridis and suspected ocular siderosis in whom no foreign material was found by conventional examination methods.

  16. Liquid-crystal intraocular adaptive lens with wireless control

    NARCIS (Netherlands)

    Simonov, A.N.; Vdovine, G.V.; Loktev, M.

    2007-01-01

    We present a prototype of an adaptive intraocular lens based on a modal liquid-crystal spatial phase modulator with wireless control. The modal corrector consists of a nematic liquid-crystal layer sandwiched between two glass substrates with transparent low- and high-ohmic electrodes, respectively.

  17. Trabeculectomy for traumatic hyphema with increased intraocular pressure.

    Science.gov (United States)

    Graul, T A; Ruttum, M S; Lloyd, M A; Radius, R L; Hyndiuk, R A

    1994-02-15

    We reviewed the medical records of 11 consecutive patients who underwent trabeculectomy with anterior chamber washout and peripheral iridectomy as the primary surgical treatment for traumatic hyphema that was unresponsive to medical management. The mean intraocular pressure before surgery was 48 mm Hg. In ten of the patients the intraocular pressure was lowered to 21 mm Hg or lower after surgery and remained below that level up to the most recent follow-up visit, which ranged from eight to 97 months. One patient required a topical beta-blocker and oral acetazolamide to lower pressure to this level after surgery. Eight patients had visual acuity of 20/60 or better at last follow-up. Corneal blood staining occurred in eight patients. Compared with other techniques for surgical management of traumatic hyphema, trabeculectomy provides a means to keep intraocular pressure lowered while the remaining blood is clearing from the anterior chamber. Trabeculectomy with anterior chamber washout and peripheral iridectomy appears to be a safe and reliable procedure in the management of traumatic hyphemas in which medical management fails to control intraocular pressure.

  18. NEW MATERIAL FOR LOW-COST INTRAOCULAR LENSES

    NARCIS (Netherlands)

    JONGEBLOED, WL; VANDERVEEN, G; KALICHARAN, D; VANANDEL, MV; BARTMAN, G; WORST, JGF

    1994-01-01

    A UV-hardening lacquer material based on polyurethane, used in Philips compact disc lens systems, was tested as suitable material for low-cost intraocular lenses (IOLs). A slightly changed composition (code number I-0.5A) came out as the best and was subsequenly tested, with reference to poly(methyl

  19. Combined aniridic intraocular lens implantation and vitreoretinal surgery

    Directory of Open Access Journals (Sweden)

    Mehta Hitendra

    2007-01-01

    Full Text Available A 45-year-old man presented with post-traumatic aniridia. We describe the combined surgery done to treat both aniridia and epiretinal membrane simultaneously. A combined aniridia intraocular lens and vitreoretinal surgery was done. The case report highlights the advantage of combined surgery in terms of cost factor and surgical time.

  20. Microscopic and spectroscopic investigation of an explanted opacified intraocular lens

    Energy Technology Data Exchange (ETDEWEB)

    Simon, V., E-mail: viosimon@phys.ubbcluj.ro [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Radu, T.; Vulpoi, A. [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Rosca, C. [Optilens Clinic of Ophthalmology, 400604 Cluj-Napoca (Romania); Eniu, D. [Iuliu Haţieganu University of Medicine and Pharmacy, Department of Molecular Sciences, 400349 Cluj-Napoca (Romania)

    2015-01-15

    Highlights: • Changes on intraocular lens (IOL) surface after implantation. • Partial opacification of IOL central area. • Elemental composition on IOL surface prior to and after implantation. • First XPS depth profiling examination of the opacifying deposits. • Cell-mediated hydroxyapatite structuring. - Abstract: The investigated polymethylmethacrylate intraocular lens explanted an year after implantation presented a fine granularity consisting of ring-like grains of about 15 μm in diameter. In order to evidence the changes occurred on intraocular lens relative to morphology, elemental composition and atomic environments, microscopic and spectroscopic analyses were carried out using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), energy-dispersive X-ray (EDS), and X-ray photoelectron (XPS) spectroscopies. The results revealed that the grains contain hydroxyapatite mineral phase. A protein layer covers the lens both in opacified and transparent zones. The amide II band is like in basal epithelial cells. The shape and size of the grains, and the XPS depth profiling results indicate the possibility of a cell-mediated process involving lens epithelial cells which fagocitated apoptotic epithelial cells, and in which the debris derived from cell necrosis were calcified. To the best of our knowledge, this is the first investigation on explanted intraocular lenses using XPS depth profiling in order to examine the inside of the opacifying deposits.

  1. Controversies in intraocular lens implantation in pediatric uveitis.

    Science.gov (United States)

    Phatak, Sumita; Lowder, Careen; Pavesio, Carlos

    2016-12-01

    Cataract is one of the most common and visually debilitating complications of pediatric uveitis. It develops as a consequence of chronic inflammation and steroid use and is seen most often in juvenile idiopathic arthritis (JIA)-associated uveitis. Cataract extraction with intraocular lens (IOL) insertion has been carried out with a measure of success in non-uveitic pediatric eyes, but in cases of uveitis, multiple factors affect the final outcome. Chronic inflammation and its sequelae such as band keratopathy, posterior synechiae, and cyclitic membranes make surgical intervention more challenging and outcome less certain. Postoperative complications like increased inflammation, glaucoma, posterior capsular opacification, retrolental membranes, and hypotony may compromise the visual outcome. Early refractive correction is imperative in pediatric eyes to prevent amblyopia. The use of contact lenses and intraocular lenses in pediatric uveitic eyes were fraught with complications in the past. Surgical interventions such as vitreo-lensectomy followed by contact lens fitting and small incision cataract surgery followed by different types of intraocular lenses have been utilized, and many reports have been published, albeit in small patient groups. This review analyzes and discusses the existing literature on intraocular lens implantation in cases of pediatric uveitic cataract surgery.

  2. Cerebral migration of intraocular silicone oil: an MRI study

    DEFF Research Database (Denmark)

    Kiilgaard, Jens Folke; Milea, Dan; Løgager, Vibeke;

    2011-01-01

    for retinal detachment. Methods: Nineteen patients included in this study were referred for silicone oil removal after uncomplicated retinal detachment surgery using internal silicone oil tamponade. Patients with a previous history of intraocular silicone oil, glaucoma or optic pit were excluded. After...

  3. Intraocular inflammation following endotamponade with high-density silicone oil.

    NARCIS (Netherlands)

    Theelen, T.; Tilanus, M.A.D.; Klevering, B.J.

    2004-01-01

    BACKGROUND: The use of a mixture of silicone oil and partially fluorinated alkanes (high-density silicone oil) has recently been suggested as intraocular tamponade in complicated retinal detachment of the inferior quadrants. We describe a series of patients who developed a clinical picture resemblin

  4. Effect of chymase on intraocular pressure in rabbits.

    Science.gov (United States)

    Konno, Takashi; Maruichi, Midori; Takai, Shinji; Oku, Hidehiro; Sugiyama, Tetsuya; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Ikeda, Tsunehiko; Miyazaki, Mizuo

    2005-11-01

    Chymase is a chymotrypsin-like serine protease that is stored exclusively in the secretory granules of mast cells and converts big endothelins to endothelin-1 (1-31). The aim of this study was to evaluate the effect of chymase on intraocular pressure in rabbits. Chymase injection (3 and 10 mU) resulted in a trend toward increased intraocular pressure and a significant increase in intraocular pressure at a dose of 10 mU compared with the control. A specific chymase inhibitor, Suc-Val-Pro-Phe(P)(OPh)(2), attenuated the ocular hypertension induced by chymase. Endothelin-1 (1-31) also caused ocular hypertension, which was inhibited by a selective endothelin ET(A) receptor antagonist, cyclo(D-Asp-Pro-D-Val-Leu-D-Trp) (BQ-123). Moreover, chymase-induced ocular hypertension was inhibited by BQ-123. These results suggest that chymase influences the regulation of intraocular pressure, and it is likely that the formation of endothelin-1 (1-31) and subsequent activation of endothelin ET(A) receptors are involved in the development of ocular hypertension induced by chymase.

  5. Effect of alpha-2-agonist premedication on intraocular pressure after selective laser trabeculoplasty

    Directory of Open Access Journals (Sweden)

    Julius T Oatts

    2015-01-01

    Full Text Available Aim: To determine the effect of alpha-2-agonist (AA premedication (PM on intraocular pressure (IOP following selective laser trabeculoplasty (SLT. Methods: Retrospective cohort study of all patients undergoing 360° SLT at an institution with two prevalent practice patterns consisting of SLT performed with PM and without premedication (NPM with AA. The association between pre- and post-operative IOP was evaluated using a linear regression model in 49 (59% PM and 34 (41% NPM eyes. Results: The prevalence of IOP elevations up to 5 mmHg 1 h postoperatively was similar in both groups, occurring in 18% of PM and in 15% of NPM. Elevations above 5 mmHg were seen in 4% of PM and 8% of NPM (P = 0.732. After correcting for age, gender, diagnosis, number of medications, and preoperative IOP, the presence or absence of AA PM had no significant association with any postoperative IOP (P > 0.5. Conclusion: The practice of using AAs before SLT and measuring IOP at 1 h has not been validated yet adds to expenses and workflow burden. Our retrospective study showed no significant correlation between PM and postoperative or longer-term IOP. IOP at 1 h should be measured in patients who cannot tolerate transient pressure elevations. Further studies are needed to elucidate this relationship.

  6. Impact of intraocular pressure on changes of blood flow in the retina, choroid, and optic nerve head in rats investigated by optical microangiography

    OpenAIRE

    Zhi, Zhongwei; Cepurna, William O.; Johnson, Elaine C.; Morrison, John C.; Wang, Ruikang K.

    2012-01-01

    In this paper, we demonstrate the use of optical coherence tomography/optical microangiography (OCT/OMAG) to image and measure the effects of acute intraocular pressure (IOP) elevation on retinal, choroidal and optic nerve head (ONH) perfusion in the rat eye. In the experiments, IOP was elevated from 10 to 100 mmHg in 10 mmHg increments. At each IOP level, three-dimensional data volumes were captured using an ultrahigh sensitive (UHS) OMAG scanning protocol for 3D volumetric perfusion imaging...

  7. Comparison of a new-generation sectorial addition multifocal intraocular lens and a diffractive apodized multifocal intraocular lens.

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Velthoven, M. van; Meulen, I. van der; Nieuwendaal, C.; Mourits, M.; Lapid-Gortzak, R.

    2012-01-01

    PURPOSE: To compare visual, refractive, and satisfactory outcomes between a new-generation sectorial addition multifocal intraocular lens (IOL) (Lentis Mplus LS-312; study group) and a diffractive apodized multifocal IOL (Restor SN6AD1; control group). SETTING: Private practice, Driebergen, and Depa

  8. Experimental study on cyclosporine A drug delivery system in prevention of posterior capsule opacification after intraocular lens implantation in rabbits

    Institute of Scientific and Technical Information of China (English)

    Pei Cheng; Sun Naixue

    2008-01-01

    Objective To study the effect of cyclosporine A drug delivery system (CsA-DDS) on the prevention of posterior capsule opacification (PCO) after experimental intraocular lens implantation in rabbit eyes. Methods Twenty healthy New Zealand white rabbits, whose left eyes and right eyes were used respectively as experiment eyes and controls, were subjected to extracapsular lens extraction and artificial lens implantation. During the operation, CsA-DDS with poly (lactideco-glycolide) as carriers or empty DDS was implanted in the capsular bag for the experimental eyes and controls respectively. After the operation, anterior chamber reaction, intraocular pressure (IOP) and CsA concentration were monitored and twelve weeks after the operation, the eyes were extracted for histopathological and morphological examinations. Results There were no differences between the two groups in conjunctival congestion,IOP change and anterior chamber reaction. PCO was less severe in the experimental eyes than in the controls. Light microscopy revealed that posterior capsular membrane in the experimental eyes was slick, with no obvious proliferation,whereas in the controls, there were lens epithelial cell proliferation and cortex regeneration of different degrees.Morphological examination with electron microscope showed that in the experimental eyes, lens epithelial cells did not function actively and apoptosis occurred, whereas in the controls, epithelial cells presented active function. No marked ultrastructural changes were found in either group. Conclusion Cs-DDS can inhibit PCO after intraocular lens implantation in rabbit eyes and does not have toxic effects on the surrounding ocular tissues. Therefore, it has a good potential for clinical use in prevention of PCO.

  9. Bucket elevator

    OpenAIRE

    2016-01-01

    Cílem této bakalářské práce je návrh svislého korečkového elevátoru, který má sloužit k dopravě obilovin s dopravní výškou 19 m a dopravovaným množstvím 100 t/hod. Práce se skládá z popisu korečkového elevátoru a jeho hlavních částí, zmiňující se v úvodní rešerši. Tato práce je zaměřena na funkční a kapacitní výpočet, určení pohonu a napínacího zařízení. Další výpočet je kontrolní, skládající se z pevnostní kontroly hnacího hřídele, výpočtu pera, životnosti ložisek a výpočtu napínacího zaříze...

  10. Gauge Transconjunctival Sutureless Vitrectomy in Eyes with Posteriorly Dislocated Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Hüseyin Dündar

    2013-04-01

    Full Text Available Pur po se: To evaluate the efficacy and safety of 23-gauge (23G pars plana vitrectomy (PPV in dislocated intraocular lens (IOL cases: In early- and late-term follow-up. Ma te ri al and Met hod: In this retrospective study, the medical records of 17 patients who underwent 23 G PPV treatment for dislocated IOL between January 2009 and June 2011 were analyzed. Detailed ophthalmologic examination was performed in all patients; intraoperative and postoperative complications were recorded. Re sults: In this study, mean follow-up time was 9.0 (4-22 months and mean age was 60.8 (8-82 years. Mean time after cataract surgery was variable (mean of 28.3 (0-80 months. Four patients had trauma history, five patients had pseudoexfoliation syndrome, and two patients had pathologic myopia. Dislocated IOL was placed into the sulcus in nine patients (52.9%. In two cases (11.7%, the IOLs were removed, and the patients were left aphakic. In two cases out of other 6 (11.7%, the dislocated IOL was changed with scleral fixation lens, whereas in the other four cases (23.5%, IOL was changed with iris claw lens. One patient (5.8% remained at the same level of vision, while twelve (70.5% cases increased two or more lines in BCVA. The vision was decreased in two cases. Intraocular pressure elevation controlled by medication was observed in one case. For two days, hypotony was observed in one patient. Dis cus si on: 23 G PPV technique is an effective and safe method for removing and repositioning of dislocated IOL in the vitreous. (Turk J Ophthalmol 2013; 43: 99-102

  11. Characteristics of Reversal Optic Cupping in Adults Glaucoma after Reduction of Intraocular Pressure

    Institute of Scientific and Technical Information of China (English)

    LiangXu; LeiLiu

    1995-01-01

    Purpose:According to Quigley's hypothesis the dense of connective tissue is the least and the pores of the lamina cribrosa are the largest at the superior and infe-rior poles of the lamina cribrosa,therefore they are the most vulnerable location to be involved in the characteristic glaucomatous optic nerve damage,To get clin-ical evidence for the hypltheses,the reversal of optic cup in adults glaucoma after reduction of intraocular pressure(IOP)was examined.Methods:The stereoscopic flicker comparison on with computerized image sys-tem was used to monitor the optic cup's changing,2 serial superposed stereo pairs were displayed alternatively and rapidly and the changing parts appeared moving Under the stereoscopic observation ,hthe changes of 3-dimention optic cup could be seen and the false positive phenomena caused by photographic angle variation,vascular pulsation could be differentiated from the characteristic change of the cup.Stereo fundus photographs were taken from 31eyes with hy-pertension glaucoma before and after treatment of reduction of IOPs which was either diamox administration or trabeculectomy.Results:the result showed that the reversal of optic cups after reduction of IOPs were mostly asymmetrical,especially at the inferior and/or superior poles.By multiple stepwise regression.it is known that the amount of the change is only correlated with the initial elevated IOP.Conclusions:The study indicated that it was the distortion and deformity of the lamina cribrosa leading to shearing stress that results in glaucomatous character-istic damage in structure and function.The individul tolerance of the lamina cribrosa to the high intraocular pressure and the locations of indivdual vulnerable at he optic nerve head are various.Eye Science1995;11:155-160.

  12. Aquaporin deletion in mice reduces intraocular pressure and aqueous fluid production.

    Science.gov (United States)

    Zhang, Duo; Vetrivel, L; Verkman, A S

    2002-06-01

    Aquaporin (AQP) water channels are expressed in the eye at sites of aqueous fluid production and outflow: AQP1 and AQP4 in nonpigmented ciliary epithelium, and AQP1 in trabecular meshwork endothelium. Novel methods were developed to compare aqueous fluid dynamics in wild-type mice versus mice lacking AQP1 and/or AQP4. Aqueous fluid production was measured by in vivo confocal microscopy after transcorneal iontophoretic introduction of fluorescein. Intraocular pressure (IOP), outflow, and anterior chamber compliance were determined from pressure measurements in response to fluid infusions using micropipettes. Aqueous fluid volume and [Cl(-)] were assayed in samples withdrawn by micropipettes. In wild-type mice (CD1 genetic background, age 4-6 wk), IOP was 16.0 +/- 0.4 mmHg (SE), aqueous fluid volume 7.2 +/- 0.3 microl, fluid production 3.6 +/- 0.2 microl/h, fluid outflow 0.36 +/- 0.06 microl/h/mmHg, and compliance 0.036 +/- 0.006 microl/mmHg. IOP was significantly decreased by up to 1.8 mmHg (P fluid production by up to 0.9 microl/h in age/litter-matched mice lacking AQP1 and/or AQP4 (outbred CD1 and inbred C57/bl6 genetic backgrounds). However, AQP deletion did not significantly affect outflow, [Cl(-)], volume, or compliance. These results provide evidence for the involvement of AQPs in intraocular pressure regulation by facilitating aqueous fluid secretion across the ciliary epithelium. AQP inhibition may thus provide a novel approach for the treatment of elevated IOP.

  13. Misdiagnosis induced intraocular lens dislocation in anterior megalophthalmos

    Institute of Scientific and Technical Information of China (English)

    WANG Qi-wei; XU Wen; ZHU Ya-nan; LI Jin-yu; ZHANG Li; YAO Ke

    2012-01-01

    Anterior megalophthalmos (AM) is an uncommon developmental anomaly of the anterior segment of the eye with a constellation of findings that includes enlarged cornea,deep anterior chamber,posterior positioning of the iris and lens,iris stroma atrophy,hypoplasia of iris dilator,pupil displacement,large capsular bag,lens subluxation,prematurely cataract and the tendency to retinal detachment.AM,especially when symptoms are mild,is not an easy disease to diagnose.We present 3 AM cases that were misdiagnosed as congenital cataract with weak zonule and megalocornea.Intraocular lenses (IOLs) dislocated after standard cataract surgeries and subsequent surgery (replacing the dislocated IOLs with iris-claw intraocular lenses) achieved satisfactory outcome.Although rare,AM should be included in the differential diagnosis of enlarged cornea and we recommend implanting Artisan lens in AM patients.

  14. Intraocular lens exchange-removing the optic intact

    Science.gov (United States)

    Lee, Matthew Hao; Webster, Diane Lesley

    2016-01-01

    Current practice for intraocular lens (IOL) exchange is to cut the optic of the posterior chamber intraocular lens (PCIOL) prior to removing it. Great care must be taken during this maneuver to avoid a posterior capsular tear. Removing the haptics from the fibrosed capsule can also be hazardous, as it may result in zonular stress and dehiscence. A technique is described for performing foldable (one-piece acrylic) IOL removal without cutting the optic. Careful visco-dissection of the haptics with a low viscosity ophthalmic viscosurgical device (OVD) in the fibrosed peripheral capsular tunnel avoids zonular or capsular stress. Internal wound enlargement permits foldable IOL removal in one piece, whilst preserving a self-sealing sutureless corneal wound. This technique may enhance the safety and efficacy of foldable IOL exchange. PMID:27366699

  15. Intraocular lens exchange-removing the optic intact.

    Science.gov (United States)

    Lee, Matthew Hao; Webster, Diane Lesley

    2016-01-01

    Current practice for intraocular lens (IOL) exchange is to cut the optic of the posterior chamber intraocular lens (PCIOL) prior to removing it. Great care must be taken during this maneuver to avoid a posterior capsular tear. Removing the haptics from the fibrosed capsule can also be hazardous, as it may result in zonular stress and dehiscence. A technique is described for performing foldable (one-piece acrylic) IOL removal without cutting the optic. Careful visco-dissection of the haptics with a low viscosity ophthalmic viscosurgical device (OVD) in the fibrosed peripheral capsular tunnel avoids zonular or capsular stress. Internal wound enlargement permits foldable IOL removal in one piece, whilst preserving a self-sealing sutureless corneal wound. This technique may enhance the safety and efficacy of foldable IOL exchange.

  16. [Treatment of primary retinal detachment. Minimal extraocular or intraocular?].

    Science.gov (United States)

    Kreissig, I

    2002-06-01

    The developments in treatment modalities for a primary retinal detachment over the last 70 years have been reviewed. There was a change from a surgery limited to the area of the break to a form of prophylactic surgery including the extent of the detachment. In between Rosengren had limited the treatment to the break with an intraocular gas bubble. A change was brought about by Custodis in 1953 who limited surgery to the break and omitted drainage. This procedure had serious postoperative complications which were eliminated by Lincoff by developing the cryosurgical detachment operation which was subsequently refined to extraocular minimal surgery. The ultimate realization of a minimal extraocular approach was the operation with a temporary balloon. Two additional intraocular procedures evolved, pneumatic retinopexy and primary vitrectomy, following one or the other pattern of treatment. With all four methods reattachment can result in 94-99% of the cases but differences can be seen in the morbidity and rate of reoperations.

  17. Early-onset Pseudoexfoliation Syndrome following Multiple Intraocular Procedures

    Directory of Open Access Journals (Sweden)

    Heydar Amini

    2012-01-01

    Full Text Available Purpose: To present early-onset ocular manifestations of pseudoexfoliation syndrome in young patients who had undergone multiple intraocular procedures. Methods: This is an observational case series, introducing four cases with histories of multiple intraocular procedures for glaucoma. Results: All reported cases demonstrated typical manifestations of pseudoexfoliation unilaterally in the eye that had undergone multiple surgeries. The diagnosis of pseudoexfoliation was made prior to the age of 50 in all subjects and the earliest manifestation was at the age of 18 in a case with primary congenital glaucoma Conclusion: The role of multiple surgical procedures, in addition to genetic predisposition, should be further investigated as a possible inciting factor predisposing to pseudoexfoliation in younger individuals.

  18. [The artificial lens: the folly of yesterday, the standard of today].

    Science.gov (United States)

    Meur, G

    1999-01-01

    Traditional cataract operation (dislocation of the crystalline lens into the vitreous body by external pressure or by needling) is nearly as old as mankind. The idea of implanting an artificial lenticulus is not new but this was only performed for the first time in 1949. In the last 50 years, a better knowledge of corneal and retinal physiology, as well as the improvements of intraocular lens material and design, have led to very safe routine surgery.

  19. A CLINICAL STUDY OF INTRAOCULAR PRESSURE CHANGES WITH VECURONIUM BROMIDE AND PANCURONIUM BROMIDE

    Directory of Open Access Journals (Sweden)

    Nagaraja

    2014-04-01

    Full Text Available BACKGROUND: The maintenance of intraocular pressure forms the mainstay of anesthetic management of intraocular surgery. It is desirable to achieve a normal or reduced intraocular pressure before the eye is opened to avoid expulsive hemorrhage and ocular disruption at the time of incision. Therefore the ideal anesthetic technique for intraocular surgery should produce a moderate reduction in intraocular pressure, or maintain intraocular pressure at near normal values and avoid marked fluctuations during surgery (George et al, 1979. The use of suxamethonium is associated with significant rise in intraocular pressure with a peak increase between 2 and 4 minutes following administration and return to base line value after 6 minutes. The outcome of eye surgery, particularly when there is globe injury depends to a large extent on good control of intraocular pressure not only during maintenance, but also at induction of anesthesia. This is usually achieved by use of non-depolarizing muscle relaxant. Pancuronium when used in relatively larger doses is known to have a faster onset of action and also the block may be prolonged. Vecuronium is intermediate acting and free of cardiovascular and other side effects even when used in larger doses. ABACKGROUND: The maintenance of intraocular pressure forms the mainstay of anesthetic management of intraocular surgery. It is desirable to achieve a normal or reduced intraocular pressure before the eye is opened to avoid expulsive hemorrhage and ocular disruption at the time of incision. Therefore the ideal anesthetic technique for intraocular surgery should produce a moderate reduction in intraocular pressure, or maintain intraocular pressure at near normal values and avoid marked fluctuations during surgery (George et al, 1979. The use of suxamethonium is associated with significant rise in intraocular pressure with a peak increase between 2 and 4 minutes following administration and return to base line value

  20. Applications of polymers in intraocular drug delivery systems

    Science.gov (United States)

    Alhalafi, Ali Mohammed

    2017-01-01

    We are entering a new era of ophthalmic pharmacology where new drugs are rapidly being developed for the treatment of anterior and posterior segment of the eye disease. The pharmacokinetics of drug delivery to the eye remains a very active area of ophthalmic research. Intraocular drug delivery systems allow the release of the drug, bypassing the blood-ocular barrier. The main advantage of these preparations is that they can release the drug over a long time with one single administration. These pharmaceutical systems are of great important in the treatment of the posterior segment diseases, and they can be prepared from biodegradable or nonbiodegradable polymers. Biodegradable polymers have the advantage of disappearing from the site of action after releasing the drug. The majority of intraocular devices are prepared from nonbiodegradable polymers, and they can release controlled amounts of drugs for months. Nonbiodegradable polymers include silicone, polyvinyl alcohol, and ethylene-vinyl acetate. The polymers usually employed to prepare nanoparticles for the topical ophthalmic route are poly (acrylic acid) derivatives (polyalquilcyanocrylates), albumin, poly-ε-caprolactone, and chitosan. Dendrimers are a recent class of polymeric materials with unique nanostructure which has been studied to discover their role in the delivery of therapeutics and imaging agents. Hydrogels are polymers that can swell in aqueous solvent system, and they hold the solvents in a swollen cross-linked gel for delivery. This review exhibits the current literature regarding applications of polymers in ophthalmic drug delivery systems including pharmacokinetics, advantages, disadvantages, and indications aimed to obtain successful eye therapy. Method of Literature Search: A systematic literature review was performed using PubMed databases into two steps. The first step was oriented to classification of intraocular polymers implants focusing on their advantages and disadvantages. The second

  1. Quantification of intraocular surgery motions with an electromagnetic tracking system.

    Science.gov (United States)

    Son, Ji; Bourges, Jean-Louis; Culjat, Martin O; Nistor, Vasile; Dutson, Erik P; Carman, Gregory P; Hubschman, Jean Pierre

    2009-01-01

    Motion tracking was performed during a combined phacoemulsification (PKE) and pars plana vitrectomy (PPV) procedure on a pig eyeball. The UCLA Laparoscopic Training System (UCLA-LTS), which consists of electromagnetic sensors attached to the surgical tools to measure three-dimensional spatial vectors, was modified to enable quantification of intraocular surgery motions. The range of motion and time taken to complete the given task were successfully recorded.

  2. Applications of polymers in intraocular drug delivery systems

    Directory of Open Access Journals (Sweden)

    Ali Mohammed Alhalafi

    2017-01-01

    Full Text Available We are entering a new era of ophthalmic pharmacology where new drugs are rapidly being developed for the treatment of anterior and posterior segment of the eye disease. The pharmacokinetics of drug delivery to the eye remains a very active area of ophthalmic research. Intraocular drug delivery systems allow the release of the drug, bypassing the blood–ocular barrier. The main advantage of these preparations is that they can release the drug over a long time with one single administration. These pharmaceutical systems are of great important in the treatment of the posterior segment diseases, and they can be prepared from biodegradable or nonbiodegradable polymers. Biodegradable polymers have the advantage of disappearing from the site of action after releasing the drug. The majority of intraocular devices are prepared from nonbiodegradable polymers, and they can release controlled amounts of drugs for months. Nonbiodegradable polymers include silicone, polyvinyl alcohol, and ethylene-vinyl acetate. The polymers usually employed to prepare nanoparticles for the topical ophthalmic route are poly (acrylic acid derivatives (polyalquilcyanocrylates, albumin, poly-μ-caprolactone, and chitosan. Dendrimers are a recent class of polymeric materials with unique nanostructure which has been studied to discover their role in the delivery of therapeutics and imaging agents. Hydrogels are polymers that can swell in aqueous solvent system, and they hold the solvents in a swollen cross-linked gel for delivery. This review exhibits the current literature regarding applications of polymers in ophthalmic drug delivery systems including pharmacokinetics, advantages, disadvantages, and indications aimed to obtain successful eye therapy. Method of Literature Search: A systematic literature review was performed using PubMed databases into two steps. The first step was oriented to classification of intraocular polymers implants focusing on their advantages and

  3. Composition of intraocular foreign bodies: experimental study of ultrasonographic presentation

    Directory of Open Access Journals (Sweden)

    Márcio Augusto Nogueira Costa

    2013-02-01

    Full Text Available PURPOSE: To investigate the reliability of ultrasound in determining the size and identify the sonographic features and artifacts generated by intraocular foreign bodies of different materials. METHODS: Experimental study using 36 enucleated porcine eyes. Fragments of nine different compositions (wood, glass, plastic, cardboard, iron, aluminum, lead, powder and concrete and similar dimensions (4 mm were implanted via scleral incision into the vitreous cavity of 36 porcine eyes, four eyes were used for each material. Ultrasound examination was performed in all eyes using the contact technique, conductive gel and 10-MHz transducer (EZScan, Sonomed. RESULTS: Considering the material fragments of gunpowder, lead, concrete, aluminum, wood and glass, the size determined by ultrasound was considered statistically similar to the actual size. The material iron presented ultrasound-determined dimension statistically smaller than its actual size. Cardboard and plastic materials showed ultrasound-determined measurements far greater than the actual. All fragments of intraocular foreign bodies demonstrated hyper-reflective interfaces, irrespective of their composition. Whereas the artifacts generated by different materials, it was found that the materials iron, aluminum and lead showed reverberation of great extent. The material wood showed no reverberation. The length of the reverberation artifact for the materials iron, glass, aluminum and cardboard was lower when compared to other materials. All materials presented posterior shadowing artifact, with the exception of aluminum. CONCLUSION: Ultrasonography was considered a reliable technique to determine the size of intraocular foreign bodies in pigs, with little influence caused by its composition. Ultrasound artifacts generated were considered material-dependent and can assist the examiner to identify the nature of a foreign body of unknown etiology. Ultrasonography aided the surgeon to identify, locate and

  4. Validation of sensor for postoperative positioning with intraocular gas

    Directory of Open Access Journals (Sweden)

    Brodie FL

    2016-05-01

    Full Text Available Frank L Brodie,1 Kelly Y Woo,2 Ashwin Balakrishna,2 Hyuck Choo,2 Robert H Grubbs2 1Department of Ophthalmology, University of California San Francisco, San Francisco, 2Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA Purpose: Surgical repair of retinal attachment or macular hole frequently requires intraocular gas. This necessitates specific postoperative positioning to improve outcomes and avoid complications. However, patients struggle with correct positioning. We have developed a novel sensor to detect the position of the gas bubble in the eye and provide feedback to patients in real time. In this paper, we determine the specificity and sensitivity of our sensor in vitro using a model eye. Methods: We assessed the reliability of our sensor to detect when a gas bubble has deviated off a model retinal break in a model eye. Various bubble sizes representing the intraocular kinetics of sulfur hexafluoride gas and varying degrees of deviation from the correct position were tested using the sensor attached to a mannequin head with a model eye. Results: We recorded 36 data points. The sensor acted appropriately in 33 (91.7% of them. The sensor triggered the alarm every time the bubble deviated off the break (n=15, sensitivity =100%. However, it triggered the alarm (falsely 3/21 times when the bubble was correctly positioned over the retinal break (specificity =86%. Conclusion: Our device shows excellent sensitivity (100% and specificity (86% in detecting whether intraocular gas is tamponading a retinal break in a model eye. Keywords: postoperative positioning, intraocular gas, vitrectomy, retinal detachment, macular hole, pneumatic retinopexy

  5. Intraocular gnathostomiasis: A rare case report from Central India

    Science.gov (United States)

    Rawat, Preeti; Gautam, Manushree; Jain, Nikhila C; Jain, Rajdeep

    2016-01-01

    We report the first case of intraocular gnathostomiasis from Central India. A 29-year-old male from Indore, Madhya Pradesh, presented with pain and redness of the right eye since 1 month. Slit lamp examination revealed anterior uveitis, multiple iris atrophic patches, and a live worm hooked on iris. The worm was removed through a small sclerocorneal tunnel. Microscopy confirmed Gnathostoma spinigerum. The patient was treated with oral albendazole and steroids. The case is reported because of its rarity. PMID:27146938

  6. Metabolic syndrome: a risk factor for high intraocular pressure in the Israeli population

    Institute of Scientific and Technical Information of China (English)

    Tamara; Wygnanski-Jaffe; Itzhak; Bieran; Dorit; Tekes-Manova; Yair; Morad; Isaac; Ashkenazi; Eedy; Mezer

    2015-01-01

    AIM: To evaluate the association among elevated intraocular pressure(IOP), the metabolic syndrome(Met S), body mass index(BMI), and some of their components in the Israeli population.METHODS: We retrospectively reviewed the charts of12 747 soldiers of the Israeli Defense Forces, aged 35 y or older, who underwent a routine periodical medical examination between 1991 and 2004. None of the subjects received medical treatment for either glaucoma or ocular hypertension. High IOP(>21 mm Hg) was correlated with age, sex, arterial blood pressure, total blood cholesterol levels, triglyceride levels, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, smoking, BMI and Met S.RESULTS: A statistically significant difference was found between the IOP of subjects with a low risk and higher risk for the development of Met S(P <0.0001 for males, P =0.0026 for females). A statistically significant positive correlation was found in male subjects between high BMI and elevated IOP(r =0.11677, P <0.0001).CONCLUSION: Met S and BMI were significantly more prevalent in subjects with increased IOP levels. We suggest that both should be taken into consideration in the assessment of glaucoma suspects.

  7. Comparison of visual performance of multifocal intraocular lenses with same material monofocal intraocular lenses.

    Directory of Open Access Journals (Sweden)

    Tomofusa Yamauchi

    Full Text Available PURPOSE: To compare the visual performance of multifocal intraocular lenses (IOLs and monofocal IOLs made of the same material. METHODS: The subjects included patients implanted with either Tecnis® monofocal IOLs (ZA9003 or ZCB00 or Tecnis® multifocal IOLs (ZMA00 or ZMB00 bilaterally. We conducted a retrospective study comparing the two types of IOLs. The multifocal group included 46 patients who were implanted with Tecnis® multifocal IOLs bilaterally. The monofocal group was an age- and sex-matched control group, and included 85 patients who were implanted with Tecnis® monofocal IOLs bilaterally. Lens opacity grading, the radius of corneal curvature, corneal astigmatism, axial length and the refractive status were measured preoperatively. Pupil size, ocular aberrometry, distance, intermediate and near visual acuity, contrast sensitivity with and without glare and the responses to a quality-of-vision questionnaire were evaluated pre- and postoperatively. RESULTS: The uncorrected near visual acuity was significantly better in the multifocal group, whereas both the corrected intermediate and near visual acuity were better in the monofocal group. Contrast sensitivity (with and without glare was significantly better in the monofocal group. The rate of spectacle dependency was significantly lower in the multifocal group. There were no significant differences between the two groups regarding most items of the postoperative quality-of-vision questionnaire (VFQ-25, with the exception that the patients in the monofocal group reported fewer problems with nighttime driving. CONCLUSIONS: The multifocal IOLs used in this study reduced spectacle dependency more so than monofocal IOLs and did not compromise the subjective visual function, with the exception of nighttime driving.

  8. [The efficacy of treating patients with intraocular hemorrhages with emoxypin].

    Science.gov (United States)

    Mokhammad, I; Cherkasov, I S

    1990-01-01

    Emoxipin, a home-made preparation approved by the Pharmacological Committee for clinical usage in 1986, is a retinal protector. Its usage is indicated for treatment of chorioretinitis, diabetic retinopathy, thrombosis of retinal vessels as well as to protects the retina from a damaging action of light of high intensity. In order to study therapeutic effectiveness of emoxipin in intraocular hemorrhages of different genesis, the preparation was used subconjunctivally, 0.5 ml of a 1% solution daily for 10-15 days. Emoxipin was used in 29 patients (29 eyes) with intraocular hemorrhages, of them, due to contusion of the eye--in 19, hypertonic disease--in 6, thrombosis of the central retinal vein--in 2, after intraocular operations--in 2 patients. As a result of the treatment, partial or almost total resolution of hemorrhages and a rise of visual acuity of different degree were recorded in all patients. Before treatment, visual acuity was from light perception to 0.04 in 26 eyes, from 0.09 to 0.3 in 3 eyes. After treatment, it rose to 0.1-0.2 in 12 eyes, to 0.3-1.0--in 17 eyes.

  9. Removal of Intralenticular Magnetic Foreign Bodies with Intraocular Magnet

    Institute of Scientific and Technical Information of China (English)

    Yiwen Luo; Zhenfang Wang; Xiaofeng Lin; Shuying Hu

    2003-01-01

    Purpose: To investigate the possibility of conservation of the lens after removal of intralenticular magnetic foreign bodies with intraocular magnet.Methods: Intralenticular magnetic foreign bodies of 15 patients were removed by using an intraocular magnet. The lens of each injury eye was conserved. Follow-up observation of these cases ranged from one to four years.Results: The intralenticular magnetic foreign bodies of 15 patients were successfully removed.The lens of each injury eye was conserved and the transparence of the lens was properly maintained. Sizes of these foreign bodies were measured, ranging from 0.3 mm to 3mm in diameter. The follow-up observation showed that the corrected visual acuity of 14 cases was not changed after operation.Conclusions: The intraocular magnet is very helpful for removal of magnetic foreign bodies from the transparent lens. This magnet allows removing of the foreign body by the surgeon and no damage to the lens was induced during the operation. Thus, maintenance of visual acuity of most of the patients can be achieved.

  10. Intraocular nematode with diffuse unilateral subacute neuroretinitis: case report

    Directory of Open Access Journals (Sweden)

    Zakariah Sakinah

    2011-06-01

    Full Text Available Abstract Background Live intraocular nematode is a rare occurrence. Nematode can migrate actively within the eye, creating visual symptoms and damaging ocular tissue. Case presentation A 26-year old man presented with painless reduced vision of the left eye for one week duration. It was associated with floaters. Visual acuity on the left eye was hand movement. Anterior segment examination was normal with normal intra-ocular pressure. Fundus examination showed a live nematode lying subretinally at the macular area with macular oedema and multifocal chorioretinal lesions at peripheral retina. There was no vitritis, vasculitis or any retinal hemorrhage. Systemic examination revealed normal findings and laboratory studies only showed leucocytosis with normal eosinophil count and negative serum toxocara antibody. The diagnosis of introcular nematode with diffuse unilateral subacute neuroretinitis was made. He was treated with oral anti-helminths and a course of oral steroid at a reducing dose. The nematode had died evidenced by its immobility during the treatment and finally disintegrated, leaving macular oedema with mottling appearance and mild hyperpigmentation. Multifocal chorioretinal lesions had also resolved. However despite treatment his visual acuity during follow-up had remained poor. Conclusions Cases of intraocular nematode, though not commonly encountered, continue to present the ophthalmologist with the problem of diagnosis and management and hence poorer prognosis to the patient.

  11. Microscopic and spectroscopic investigation of an explanted opacified intraocular lens

    Science.gov (United States)

    Simon, V.; Radu, T.; Vulpoi, A.; Rosca, C.; Eniu, D.

    2015-01-01

    The investigated polymethylmethacrylate intraocular lens explanted an year after implantation presented a fine granularity consisting of ring-like grains of about 15 μm in diameter. In order to evidence the changes occurred on intraocular lens relative to morphology, elemental composition and atomic environments, microscopic and spectroscopic analyses were carried out using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), energy-dispersive X-ray (EDS), and X-ray photoelectron (XPS) spectroscopies. The results revealed that the grains contain hydroxyapatite mineral phase. A protein layer covers the lens both in opacified and transparent zones. The amide II band is like in basal epithelial cells. The shape and size of the grains, and the XPS depth profiling results indicate the possibility of a cell-mediated process involving lens epithelial cells which fagocitated apoptotic epithelial cells, and in which the debris derived from cell necrosis were calcified. To the best of our knowledge, this is the first investigation on explanted intraocular lenses using XPS depth profiling in order to examine the inside of the opacifying deposits.

  12. Posterior chamber phakic intraocular lens implantation for high myopia

    Institute of Scientific and Technical Information of China (English)

    沈晔; 杜持新; 顾扬顺; 王竞

    2003-01-01

    Objective To evaluate the efficacy, safety and stability of posterior chamber phakic intraocular lens (PIOLs) implantation for the correction of high myopia.Methods Thirty-nine eyes of twenty patients with high myopia (between-11.75 and-25.75 diopters) had a posterior chamber PIOL (Staar ICL) implanted. During 6-48 months' follow-up, visual acuity, refraction, intraocular pressure (IOP), corneal reaction and space between crystal lens and intraocular lens (IOLs) were tested.Results Successful implantation was achieved in all patients. Visual acuity without correction greater than 0.5 was found in 34 eyes at 1 day and 3 months postoperatively. Thirty-five eyes maintained a low negative power of refraction (-1.42±1.32 doipters), which did not prevent the patients from most of their daily activities. During 3-48 months' follow-up, refraction was stable and no cornea edema and glaucoma was found. Two eyes of one patient had corticosteroid glaucoma and another eye showed cataractogenesis under anterior capsular membrane.Conclusion Posterior chamber PIOL implantation is predictable, safe, and effective in the correction of high myopia, and its indications should be carefully selected.

  13. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  14. Coculture with intraocular lens material-activated macrophages induces an inflammatory phenotype in lens epithelial cells.

    Science.gov (United States)

    Pintwala, Robert; Postnikoff, Cameron; Molladavoodi, Sara; Gorbet, Maud

    2015-03-01

    Cataracts are the leading cause of blindness worldwide, requiring surgical implantation of an intraocular lens. Despite evidence of leukocyte ingress into the postoperative lens, few studies have investigated the leukocyte response to intraocular lens materials. A novel coculture model was developed to examine macrophage activation by hydrophilic acrylic (poly(2-hydroxyethyl methacrylate)) and hydrophobic acrylic (polymethylmethacrylate) commercial intraocular lens. The human monocytic cell line THP-1 was differentiated into macrophages and cocultured with human lens epithelial cell line (HLE-B3) with or without an intraocular lens for one, two, four, or six days. Using flow cytometry and confocal microscopy, expression of the macrophage activation marker CD54 (intercellular adhesion molecule-1) and production of reactive oxygen species via the fluorogenic probe 2',7'-dichlorodihydrofluorescein diacetate were examined in macrophages. α-Smooth muscle actin, a transdifferentiation marker, was characterized in lens epithelial cells. The poly(2-hydroxyethyl methacrylate) intraocular lens prevented adhesion but induced significant macrophage activation (p intraocular lens), while the polymethylmethacrylate intraocular lens enabled adhesion and multinucleated fusion, but induced no significant activation. Coculture with either intraocular lens increased reactive oxygen species production in macrophages after one day (p intraocular lens, with hydrophilic surfaces inducing higher activation than hydrophobic surfaces. These findings provide a new method of inquiry into uveal biocompatibility, specifically through the quantification of cell-surface markers of leukocyte activation.

  15. Artificial Economy

    Directory of Open Access Journals (Sweden)

    Alexandru JIVAN

    2011-08-01

    Full Text Available This paper proposes to eliminate, a routine in the economic thinking, claimed to be responsible for the negative essence of economic developments, from the point of view, of the ecological implications (employment in the planetary ecosystem. The methodological foundations start from the natural origins of the functionality of the human economic society according to the originary physiocrat liberalism, and from specific natural characteristics of the humankind. This paper begins with a comment-analysis of the difference between natural and artificial within the economy, and then explains some of the most serious diversions from the natural essence of economic liberalism. It shall be explained the original (heterodox interpretation of the Classical political economy (economics, by making calls to the Romanian economic thinking from aggravating past century. Highlighting the destructive impact of the economy - which, under the invoked doctrines, we call unnatural - allows an intuitive presentation of a logical extension of Marshall's market price, based on previous research. Besides the doctrinal arguments presented, the economic realities inventoried along the way (major deficiencies and effects, determined demonstrate the validity of the hypothesis of the unnatural character and therefore necessarily to be corrected, of the concept and of the mechanisms of the current economy.The results of this paper consist of original heterodox methodspresented, intuitive or developed that can be found conclusively within the key proposals for education and regulation.

  16. Experimental intraocular infection of exotic cockerels with field strain of velogenic Newcastle disease virus in Nigeria

    Directory of Open Access Journals (Sweden)

    Samaila Jonathan Badau

    2015-12-01

    Full Text Available Experimental intraocular (conjunctival infection of exotic cockerels with a new field strain of viscerotropic velogenic Newcastle Disease Virus (NDV was conducted to explore the concurrence of some pathological changes with humoral immune responses. After the NDV infection of 4-week-old cockerels, pathologic changes and antibody responses were observed. The clinical signs observed after the artificial inoculation included inappetence, depression, diarrhea, dyspnea, wing and leg paralysis, torticollis and weight loss. Morbidity due to the NDV was 100%, but mortality was 80% by day 18-21 post-infection. Early hyperthermia followed by terminal hypothermia, decreased packed cell volume (PCV, and 231.4 folds peak-antibody response were observed. Necrotic and/or inflammatory lesions were present in the proventriculus, intestine, liver, spleen, kidney and brain. Neurologic and digestive tract perturbations occurred in 10% and 85% of cases, respectively. The disease consistently caused stunted growth, decreased PCV, and necro-inflammatroy lesions concurrent with antibody response, suggesting probable involvement of immune-mediated mechanisms and cell membrane desialylation by viral neuraminidase in the pathogenesis.

  17. Determination of Tear Production and Intraocular Pressure With Rebound Tonometry in Wild Humboldt Penguins ( Spheniscus humboldti ).

    Science.gov (United States)

    Sheldon, Julie D; Adkesson, Michael J; Allender, Matthew C; Jankowski, Gwen; Langan, Jennifer; Cardeña, Marco; Cárdenas-Alayza, Susana

    2017-03-01

    Tear production and intraocular pressures (IOPs) were determined in 38 and 102 wild Humboldt penguins (Spheniscus humboldti), respectively, from the Punta San Juan Marine Protected Area in Ica, Peru. Tear production was measured by Schirmer tear test, and IOP was measured with a TonoVet rebound tonometer. Adult (n = 90) and chick (n = 12) penguins were sampled from 2 different beaches (north and south facing) during 2 sampling years (2010 and 2011). Results showed a mean ± SD (range) of 9 ± 4 (2-20) mm/min for tear production and 28 ± 9 (3-49) mm Hg for IOP. Tear production in penguins differed between beach and sex, whereas IOP differed between age, year, and beach. The IOPs were negatively correlated with packed cell volume. Tear production and IOP values had greater variation in this population than it has in other avian species. Previous investigations of IOP and tear production in Spheniscus species were conducted with birds housed under professional care in artificial marine and freshwater environments. This is the first study, to our knowledge, investigating tear production and IOP in wild penguins and establishes valuable reference intervals for this species.

  18. Preoperative automatic visual behavioural analysis as a tool for intraocular lens choice in cataract surgery

    Directory of Open Access Journals (Sweden)

    Heloisa Neumann Nogueira

    2015-04-01

    Full Text Available Purpose: Cataract is the main cause of blindness, affecting 18 million people worldwide, with the highest incidence in the population above 50 years of age. Low visual acuity caused by cataract may have a negative impact on patient quality of life. The current treatment is surgery in order to replace the natural lens with an artificial intraocular lens (IOL, which can be mono- or multifocal. However, due to potential side effects, IOLs must be carefully chosen to ensure higher patient satisfaction. Thus, studies on the visual behavior of these patients may be an important tool to determine the best type of IOL implantation. This study proposed an anamnestic add-on for optimizing the choice of IOL. Methods: We used a camera that automatically takes pictures, documenting the patient’s visual routine in order to obtain additional information about the frequency of distant, intermediate, and near sights. Results: The results indicated an estimated frequency percentage, suggesting that visual analysis of routine photographic records of a patient with cataract may be useful for understanding behavioural gaze and for choosing visual management strategy after cataract surgery, simultaneously stimulating interest for customized IOL manufacturing according to individual needs.

  19. Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens

    Science.gov (United States)

    Lee, Shinwook; Choi, Myoung; Xu, Zaiwei; Zhao, Zeyu; Alexander, Elsinore; Liu, Yueai

    2016-01-01

    Purpose The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. Methods The optical characteristics of AcrySof® IQ PanOptix™ (PanOptix) and AcrySof® IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal images, simulated headlight images, and modulation transfer function (MTF) measurements which determine resolution, photic phenomena, and image quality. Through-focus Badal images of an Early Treatment of Diabetic Retinopathy Study chart were recorded at both photopic and mesopic pupil sizes. Simulated headlight images were taken on an MTF bench with a 50-μm pinhole target and a 5.0 mm pupil at the distance focus of the IOL. MTF curves were measured with a 3.0 mm pupil, and spatial frequencies equivalent to 20/40 and 20/20 visual acuities were recorded to illustrate the through-focus MTF curves. Far-, intermediate-, and near-focus MTF values were obtained. Results Bench Badal image testing and MTF measurements showed that PanOptix has a near focus at a distance of 42 cm and an additional intermediate focus at a distance of about 60 cm. The near focus for ReSTOR +3.0 D is at 45 cm. PanOptix and ReSTOR +3.0 D have comparable photopic distances and near MTF values. Additionally, PanOptix provided a substantial continuous range of vision from distance to intermediate and to near compared with ReSTOR +3.0 D. The halo propensity for PanOptix was slightly higher than that for ReSTOR +3.0 D. Conclusion Laboratory-based in vitro simulations showed that PanOptix trifocal IOL has comparable resolution and image quality performance in distance and near foci compared with ReSTOR +3.0 D IOL. PanOptix showed better resolution and image quality performance at the intermediate focus than ReSTOR +3.0 D IOL. PMID:27330273

  20. Muscular and intraocular pressure responses among ocular-hypertensive subjects: is there a rationale for biofeedback?

    Science.gov (United States)

    Raczynski, J M; Mason, D A; Wilson, R P; Silvia, E S; Kleinstein, R N

    1985-12-01

    Several animal and human investigations have indicated that intraocular pressure (IOP) levels may be associated with extreme drug-induced changes in the extraocular muscles. Further, recent data suggest that, among individuals with normal IOP level, moderate increases in facial muscle (EMG) activity around the eye while the eye is open are associated with increases in IOP. To investigate further the relationship between facial EMG activity and IOP levels and to examine a group of individuals with elevated IOP levels, subjects were recruited from outpatients at an optometry clinic. Three groups of subjects were selected: a group of ocular hypertensive subjects who showed elevated pressures at the optometry clinic and upon the day of testing, a group of labile ocular hypertensive subjects who evinced elevated pressures during their visit to the optometry clinic but lower pressures on the day of testing, and a group of normal IOP subjects who showed normal pressures both during their optometry clinic visit and on the day of testing. To investigate anxiety differences, subjects were administered the State-Trait Anxiety Inventory, but subsequent analysis revealed no group differences. To evaluate the role of stress upon muscle (EMG) functioning around the eye, subjects were subjected to imagery and standardized mental arithmetic stressors; analyses of these results also revealed no significant group differences. Finally, subjects were given EMG biofeedback for muscle activity around the eye while IOP was assessed during five alternating periods in which they made decreases and increases in EMG activity. Results revealed significant group, period, and group by period interaction effects. The pattern of results is interpreted as implicating EMG activity in IOP fluctuations; the implications of these data for potential biofeedback and stress management treatments are discussed.

  1. Extracapsular cataract extraction : the fate of retained lens material and intraocular lenses

    NARCIS (Netherlands)

    J.P. Kappelhof (Johan)

    1987-01-01

    textabstractThe aim of this study was to examine the fate of the lens material that remains in the eye after an extracapsular cataract extraction both with and without insertion of an intraocular lens. Apart from this, the development of precipitates on the intraocular lenses was morphologically inv

  2. Vitreoretinal Surgery for Intraocular Lens Dislocated into the Vitreous Cavity

    Directory of Open Access Journals (Sweden)

    Dilek Özçelik Soba

    2015-04-01

    Full Text Available Objectives: To investigate the sex, age, accompanying eye examination findings, and the outcomes of vitreoretinal surgery (VRS for intraocular lens (IOL dislocated into the vitreous cavity. Materials and Methods: The medical records of 30 patients who underwent VRS for IOL dislocation into the vitreous cavity were retrospectively analyzed in this study. Preoperative and postoperative visual acuity, intraocular pressure, biomicroscopic, and posterior segment examination findings were assessed. Results: The average age of the patients was 63.1 (range: 38-83 years. Twenty-one patients were male (70% and 9 patients were female (30%. As etiologic causes, 18 cases (60% had late spontaneous dislocation, 5 cases (16.6% had dislocation after phacoemulsification surgery, 4 cases (13.3% had trauma, 2 cases (6.6% had previously undergone vitrectomy, and 1 case (3.3% had undergone YAG laser capsulotomy. VRS including 23-gauge triamcinolone-assisted pars plana vitrectomy, intraocular lens extraction, posterior hyaloid membrane removing, endolaser photocoagulation, and fluid-air exchange was performed. Posterior chamber IOL implantation on to the anterior capsule in 13 cases (43.3%, anterior chamber IOL implantation in 10 cases (33.3%, and scleral fixated posterior IOL implantation in 4 cases (13.3% were performed. The corrected visual acuity recorded at the last follow-up was better than the first visit in 23 cases (76.6%, the same in 5 eyes (16.6%, and worse in 2 eyes (6.6%. Conclusion: VRS combined IOL implantation is a successful surgery method for IOL dislocated into the vitreous cavity and can avoid poor visual outcomes. (Turk J Ophthalmol 2015; 45: 56-9

  3. Clinical analysis of suprachoroidal hemorrhage complicated by intraocular surgery

    Directory of Open Access Journals (Sweden)

    Man-Hong Li

    2017-02-01

    Full Text Available AIM:To explore clinical characteristics of supracho-roidal hemorrhage(SCHcomplicated by intraocular surgery and to observe visual prognosis. METHODS:A total of 13 eyes(13 caseswith SCH related to intraocular surgery from June 2005 to June 2015 were included and respectively studied. The age of our cases ranged from 22 to 76. Of all, 4 eyes(31%were concomitant with hypertension, 6 eyes(46%with high myopia and 6 eyes(46%with oculi hypertonia, respectively. Intraoperative expulsive SCH occurred in 8 eyes, while postoperative delayed SCH in 5 eyes. The most SCH(7 eyeshappened during the surgery of removing silicone oil, 4 eyes with SCH were related to extracapsular cataract extraction(ECCE, 1 SCH eye was complicated by ECCE combined with trabeculectomy and 1 SCH eye by lensectomy and vitrectomy. As for treatment, 5 eyes took medication alone, 4 eyes were performed drainage sclerotomy and gas tamponade, while the other 4 eyes were accomplished vitrectomy with adjunctive perfluoro-carbon liquids and silicone oil tamponade. RESULTS:At the 10-month of follow-up, all eyes with SCH were resolved. Except 1 eye with no light perception owing to abandoning treatment, the sights of the other 12 eyes were between light perception and 0.4. CONCLUSION:SCH complicated by intraocular surgery was rare but with devastating outcome. Aged patients, hypertension, high myopia and oculi hypertonia may be risk factors. In addition, surgical methods in the early years were likely correlated to the occurrence of SCH. Certain sight of the patients with SCH may be maintained after positive treatment.

  4. UV solid state laser ablation of intraocular lenses

    Science.gov (United States)

    Apostolopoulos, A.; Lagiou, D. P.; Evangelatos, Ch.; Spyratou, E.; Bacharis, C.; Makropoulou, M.; Serafetinides, A. A.

    2013-06-01

    Commercially available intraocular lenses (IOLs) are manufactured from silicone and acrylic, both rigid (e.g. PMMA) and foldable (hydrophobic or hydrophilic acrylic biomaterials), behaving different mechanical and optical properties. Recently, the use of apodizing technology to design new diffractive-refractive multifocals improved the refractive outcome of these intraocular lenses, providing good distant and near vision. There is also a major ongoing effort to refine laser refractive surgery to correct other defects besides conventional refractive errors. Using phakic IOLs to treat high myopia potentially provides better predictability and optical quality than corneal-based refractive surgery. The aim of this work was to investigate the effect of laser ablation on IOL surface shaping, by drilling circular arrays of holes, with a homemade motorized rotation stage, and scattered holes on the polymer surface. In material science, the most popular lasers used for polymer machining are the UV lasers, and, therefore, we tried in this work the 3rd and the 5th harmonic of a Q-switched Nd:YAG laser (λ=355 nm and λ=213 nm respectively). The morphology of the ablated IOL surface was examined with a scanning electron microscope (SEM, Fei - Innova Nanoscope) at various laser parameters. Quantitative measurements were performed with a contact profilometer (Dektak-150), in which a mechanical stylus scanned across the surface of gold-coated IOLs (after SEM imaging) to measure variations in surface height and, finally, the ablation rates were also mathematically simulated for depicting the possible laser ablation mechanism(s). The experimental results and the theoretical modelling of UV laser interaction with polymeric IOLs are discussed in relation with the physical (optical, mechanical and thermal) properties of the material, in addition to laser radiation parameters (laser energy fluence, number of pulses). The qualitative aspects of laser ablation at λ=213 nm reveal a

  5. First reported case of intraocular Gnathostoma spinigerum in Cambodia.

    Science.gov (United States)

    Hem, S; Tarantola, A; Chheang, R; Nop, P; Kerléguer, A

    2015-12-01

    A live intraocular nematode was identified from a 37 year-old man presented with iritis, pain, redness, lacrimation, swelling, vision loss and intermittent blindness during many hours per day of the left eye. By using slit lamp examination, a worm was removed from iris in an ophthalmology outpatient department setting and sent to the Medical Microbiology Laboratory, Institut Pasteur du Cambodge. Gnathostoma spinigerum was identified, based on its typical morphology via microscopic examination. Based on our diagnosis, the patient was treated by oral albendazole and responded well to this therapy.

  6. Repositioning a decentered intraocular lens with 4 haptics.

    Science.gov (United States)

    Liu, Jiewei; Liu, Wenjie; Jia, Yading; Al-Mohtaseb, Zaina N; Wang, Li

    2016-03-01

    We describe a technique to reposition a decentered 4-haptic intraocular lens (IOL). Using an ophthalmic viscosurgical device, the haptic with the worst distortion is dissected from the capsular bag and pulled outside the bag. The opposite haptic (180 degrees away) is also dissected and placed in front of the anterior capsule. The remaining 2 haptics are left in the capsular bag. With this repositioning, the 2 haptics in the bag limit the IOL movement, the 2 haptics outside the bag are no longer distorted, and the IOL is centered. We present 2 cases in which this technique was used to reposition decentered 4-haptic IOLs.

  7. Effect of transscleral neodymium: YAG cyclophotocoagulation on intraocular lenses

    Energy Technology Data Exchange (ETDEWEB)

    Blomquist, P.H.; Gross, R.L.; Koch, D.D. (Baylor College of Medicine, Houston, TX (USA))

    1990-03-01

    A neodymium: YAG laser operating in the thermal mode was used to irradiate isolated intraocular lenses (IOLs) and to perform transscleral cyclophotocoagulation on pseudophakic autopsy eyes to investigate the potential damage to IOL haptics such irradiation may cause. In the isolated IOLs, 70 mJ of energy deformed and partially melted both polymethylmethacrylate (PMMA) and polypropylene haptics. One of the capsular-fixated PC-IOL haptics in an autopsy eye partially melted when irradiated with the maximum energy level (8.8 J), with the aiming beam focused 1 mm posterior to the limbus and maximal posterior focus offset.

  8. Delayed Hyphema after Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    A56-year-old man with senile cataract in the left eye underwent extracapsularcataract extraction(ECCE)and posteriorchamber intraocular lens(IOL)implanta-tion on December 19,1988.A 13D J-loopplannar lens was inserted in the ciliary sul-cus.The operation was successful with mildpostoperative response.His corrected visionwas 20/20. He had a follow-up examination onMarch 20,1989.No complication was notedand his vision retained 20/20.In theevening of the same day,the patient sud-denly felt discomfortable and...

  9. Akreos Adapt AO Intraocular Lens Opacification: A Case Report

    Directory of Open Access Journals (Sweden)

    Matteo Forlini

    2013-09-01

    Full Text Available A 79-year-old hyperglycemic patient was referred to the ‘Santa Maria delle Croci' Hospital, Ravenna, Italy. He presented with visual impairment in the right eye. Four years ago, he had had an uneventful cataract surgery in the right eye. We observed an opacification of the intraocular lens (IOL causing significant visual disturbance. The IOL was exchanged. Unfortunately, pathologic analysis was not performed. Patient-related factors such as hyperglycemia and hypertension might have been responsible for the opacification. To our knowledge, there is only one previous report of opacification of the Akreos Adapt AO IOL.

  10. Technology needs for the development of the accommodative intraocular lens

    Science.gov (United States)

    Nishi, Okihiro

    2010-02-01

    Refilling the lens capsule while preserving capsular integrity offers the potential to restore ocular accommodation. There are two persisting problems in capsular bag refilling for possible clinical application: Leakage of the injectable material through the capsular opening and capsular opacification. Numerous attempts for solving these cardinal problems have not been proven to be clinically applicable. Recently, we developed a novel capsular bag refilling procedure using a novel accommodative intraocular lens that serves as an optic as well as a plug for sealing the capsular opening. The procedure and the results of monkey experiments will be presented.

  11. Unilateral Crystalline Vitreoretinopathy: A Rare Entity Associated with Intraocular Inflammation

    Directory of Open Access Journals (Sweden)

    Kaustubh B. Harshey

    2015-01-01

    Full Text Available A 31-year-old Indian male presented with floaters and diminution of vision in the right eye. Ocular examination showed features of old anterior uveitis with posterior subcapsular cataract and fine, refractile crystals in the vitreous cavity and on the retinal surface. A thorough workup for all known causes of crystalline retinopathy was inconclusive. Unilateral crystalline retinopathy has been sparingly reported. This is the first report of unilateral, crystalline vitreoretinopathy in the absence of any demonstrable and known cause for intraocular crystals.

  12. How to measure intraocular pressure: Schiötz tonometry

    Directory of Open Access Journals (Sweden)

    Sue Stevens

    2008-06-01

    Full Text Available If glaucoma is diagnosed early, treatment can then be given that may preserve vision. Although raised intraocular pressure (IOP is not the only sign of glaucoma, the IOP should be checked routinely on all adults attending eye care facilities. Applanation tonometry (as described in Issue 64, December 2007 is the most accurate method to measure IOP, but Schiötz tonometry is also a useful screening test. If Schiötz tonometry reveals a high IOP, this result should be checked and confirmed by applanation tonometry and the patient referred to the senior clinician at the eye clinic.

  13. Risk factors for intraocular penetration of caterpillar hair in Ophthalmia Nodosa: A retrospective analysis

    Directory of Open Access Journals (Sweden)

    Sengupta Sabyasachi

    2010-01-01

    Full Text Available We report risk factors associated with intraocular penetration of caterpillar hair seen at our institute from January 2005 to December 2007. Records of all patients with caterpillar hair induced ophthalmitis (CHIO were retrospectively reviewed for clinical characteristics, anatomic location of lodgment of the caterpillar hair, treatment methods, and outcomes. Out of a total of 544 cases of CHIO, 19 eyes (seven in the anterior chamber and 12 in the posterior segment experienced intraocular penetration (3.5%. The presence of deep intracorneal hair (80 cases, 14.7% was found to be the only risk factor for intraocular penetration ( P < 0.001. The removal of intracorneal hair was possible in only 29 out of 80 eyes (36% and this was associated with a significantly reduced risk of intraocular penetration ( P = 0.022. Patients with retained intracorneal hairs should be counseled regarding risk of intraocular penetration and closely followed up for at least six months.

  14. Intraocular and systemic levels of vascular endothelial growth factor in advanced cases of retinopathy of prematurity

    Science.gov (United States)

    Velez-Montoya, Raul; Clapp, Carmen; Rivera, Jose Carlos; Garcia-Aguirre, Gerardo; Morales-Cantón, Virgilio; Fromow-Guerra, Jans; Guerrero-Naranjo, Jose Luis; Quiroz-Mercado, Hugo

    2010-01-01

    Purpose: To measure vitreous, aqueous, subretinal fluid and plasma levels of vascular endothelial growth factor in late stages of retinopathy of prematurity. Methods: Interventional study. We enrolled patients with clinical diagnoses of bilateral stage V retinopathy of prematurity, confirmed by b-scan ultrasound and programmed for vitrectomy. During surgery we took samples from blood, aqueous, vitreous, and subretinal fluids. The vascular endothelial growth factor concentration in each sample was measured by ELISA reaction. A control sample of aqueous, vitreous and blood was taken from patients with congenital cataract programmed for phacoemulsification. For statistical analysis, a Mann–Whitney and a Wilcoxon W test was done with a significant P value of 0.05. Results: We took samples of 16 consecutive patients who met the inclusion criteria. The vascular endothelial growth factor levels in the study group were: aqueous, 76.81 ± 61.89 pg/mL; vitreous, 118.53 ± 65.87 pg/mL; subretinal fluid, 1636.58 ± 356.47 pg/mL; and plasma, 74.64 ± 43.94 pg/mL. There was a statistical difference between the study and the control group (P < 0.001) in the aqueous and vitreous samples. Conclusion: Stage 5 retinopathy of prematurity has elevated intraocular levels of vascular endothelial growth factor, which remains high despite severe retinal lesion. There was no statistical difference in plasma levels of the molecule between the control and study group. PMID:20856587

  15. Screening of intraocular pressure before routine pupil dilation for retinal photography: Clinical case report

    Directory of Open Access Journals (Sweden)

    Lap-kin Chiang

    2016-12-01

    Full Text Available Introduction: Pharmacologic dilation of the pupil results in twice the sensitivity of detection of diabetic retinopathy compared with undilated retinal examination. The potential risk of acute angle-closure glaucoma after pupil dilation has been hypothesized to be higher in Asian patients with diabetes mellitus. Clinical case: A 61-year-old man with diabetes mellitus and hypertension was incidentally found to have elevated intraocular pressure (IOP before routine retinal photography. He was asymptomatic and the visual acuity was 0.67 for both eyes. An ophthalmologist later found he had anatomical narrow-angle borderline glaucoma. Topical administration of pilocarpine and oral administration of acetazolamide were initiated, and laser iridotomy was later performed. IOP screening: Among 1736 diabetic and/or hypertensive patients who underwent IOP screening, 31 patients (1.8% had IOP of any eye persistently higher than 21 mm Hg on at least two occasions. The mean (standard deviation IOP of the right eye was 24.1 (2.1 mm Hg, while that of the left eye was 24.6 (2.5 mm Hg. Four patients (12.9% were found to have glaucoma, and treatment was initiated by an ophthalmologist. Therefore further study should be conducted to evaluate the cost-effectiveness of IOP screening among this group of patients.

  16. Mirtogenol® potentiates latanoprost in lowering intraocular pressure and improves ocular blood flow in asymptomatic subjects

    Directory of Open Access Journals (Sweden)

    Robert D Steigerwalt Jr

    2010-05-01

    Full Text Available Robert D Steigerwalt Jr1, Gianni Belcaro1, Paolo Morazzoni2, Ezio Bombardelli2, Carolina Burki3, Frank Schönlau4 1Department of Biomedical Sciences, University of Chieti-Pescara, San Valentino, Italy; 2Indena S.p.A. Scientific Department, Milan, Italy; 3Horphag Research (UK Ltd., Geneva, Switzerland; 4Horphag Research (UK Ltd. South Kensington, London UKPurpose: The dietary supplement Mirtogenol® was previously shown to lower elevated intraocular pressure (IOP. We here present the effects of this supplement on IOP in comparison as well as in combination with latanoprost eye drops. Methods: Seventy-nine patients with asymptomatic ocular hypertension were randomly assigned to three groups receiving either the supplement, or latanoprost eye drops, or both in combination. Intraocular pressure and retinal blood flow were investigated in monthly intervals over 24 weeks.Results: Mirtogenol alone lowered IOP from baseline 38.1 to 29.0 mmHg after 16 weeks, with little further improvement during the following eight weeks. Latanoprost rapidly lowered IOP from baseline 37.7 to 27.2 mmHg within four weeks, without further effects thereafter. The combination of the supplement and latanoprost lowered IOP from 38.0 to 27.3 mmHg after four weeks, and further decreased IOP to 24.2 mmHg after six weeks. After 24 weeks IOP with the combination treatment (23.0 mmHg was significantly lower than with latanoprost alone (27.2 mmHg. Mirtogenol and latanoprost individually showed comparable effects for gradually increasing central artery blood flow with treatment duration. Combination treatment showed higher systolic blood flow velocity throughout the trial period. The diastolic blood flow velocity gradually increased with treatment duration in all three groups. From twelve weeks onwards, the diastolic component with combination treatment was higher than with individual treatments.Conclusions: Mirtogenol lowered elevated IOP in patients almost as effectively as

  17. Ultrasound Biomicroscopy of Iris-claw Phakic Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Ayong Yu; Zhende Lin; Xiaoyu Cai; Xiuqi Chen; Shuke Luo; Yonghua Li

    2006-01-01

    Purpose: To study in situ the intraocular position of iris-claw phakic intraocular lens (ICPIOL) in myopic eyes using ultrasound biomicroscopy (UBM).Methods: UBM echograms of the anterior segment were taken preoperatively and 62to 115 days postoperatively in 6 eyes implanted with the Verisys ICPIOL (AMO). The echograms were assessed for the effect of the ICPIOL on iris tissue.Results: The preoperative distance between the corneal endothelium and the lens ranged from 2.96 to 3.09 mm, and the postoperative distance between the ICPIOL and the corneal endothelium, from 1.86 to 2.03 mm. The distance between the lens and the posterior surface of the ICPIOL ranged from 0.61 to 0.76 mm. The distance between the superior, inferior optic edge and the iris ranged from 0.49 to 1.00 mm,0.21 to 0.51 mm respectively. The shortest distance between the ICPIOL haptics and the angle of anterior chamber ranged from 1.25 to 1.65 mm. The indentation of iris tissue by the ICPIOL haptics without pigmentary dispersion and distortion of posterior curvature of iris was observed.Conclusion: Adequate space is maintained between the Verisyse myopic ICPIOL and the corneal endothelium, angle, and crystalline lens. Haptic indentation of the iris without pigment erosion and distortion of iris curvature is noted. The ICPIOL implanted in phakic eyes is a safe alternative for treatment of high myopia.

  18. Intraocular lenses and clinical treatment in paediatric cataract

    Directory of Open Access Journals (Sweden)

    Camila Ribeiro Koch Pena

    2015-06-01

    Full Text Available Pediatric cataract is the most common treatable cause of blindness in children. Prevalence, etiology and morphology vary with the socioeconomic development. The treatment goal is to reduce amblyopia, being difficult management especially in unilateral cases. The decision on aphakia or primary intraocular lens should be individualized as well as correction with contact lens or spectacles. The intraocular lens single-piece hydrophobic acrylic are the most implanted in children and the preferably is in the capsular bag. The Sanders-Retzlaff-Kraff theoretic (SRK/T stressing that is described as more predictable, following Holladay I and SRK II and the recommendation is to under correction +6.0 or +8.0 dioptrias expecting the growth of the eye. The posterior capsule opacity is the most frequent complication and varies with the material choice of the lens. Glaucoma is the most serious postoperative complication and depends on the timing of the surgery, primary lens implantation and time of post surgical follow-up. The adherence to occlusion therapy with patching is critical to the visual prognosis and is determined by the child’s age and laterality of the cataract. There was significant improvement in the surgery and in IOLs, however the final visual prognosis is still not desirable.

  19. Posterior Iris Fixated Intraocular Lens for Pediatric Traumatic Cataract

    Science.gov (United States)

    Kavitha, V.; Balasubramanian, Preethi; Heralgi, Mallikarjun M.

    2016-01-01

    Purpose: To evaluate the postoperative visual outcomes and complications of posterior iris fixated intraocular lens (IFIOL) implantation for pediatric traumatic cataract. Methods: A retrospective clinical audit was performed of all the pediatric traumatic cataract patients who underwent lens removal and iris fixated lens implantation due to inadequate capsular support with or without corneal tear repair between January 2009 and December 2013. Data were collected and analyzed on the preoperative and postoperative visual outcomes and complications. Results: Twenty-five children (25 eyes; 21 males and 4 females) were enrolled with the mean age of 11 ± 4.0 years. There were 72% of eyes that underwent primary cataract removal with IFIOL implantation. Twenty-eight percent of eyes underwent corneal tear repair prior to intraocular lens (IOL) implantation. Preoperative best corrected visual acuity (BCVA) was hand motion in 32% eyes, counting fingers in 24%, and perception of light in 44%. Postoperative BCVA of 0-0.2 logarithm of minimum angle of resolution was reported in the 64% of eyes. One eye developed secondary glaucoma, one eye underwent re-enclavation, and none developed retinal complications. Conclusion: Posterior IFIOL implantation resulted in an improved visual outcome, low incidence of postoperative complications, and is a good alternative to other IOL, in the cases of pediatric traumatic cataract without adequate capsular support. PMID:27162456

  20. Analyses of ERG in a patient with intraocular lymphoma

    Directory of Open Access Journals (Sweden)

    Chieko Yasuda

    2010-04-01

    Full Text Available Chieko Yasuda, Shinji Ueno, Mineo Kondo, Nagako Kondo, Chang-Hua Piao, Hiroko TerasakiDepartment of Ophthalmology, Nagoya University School of Medicine, Nagoya, JapanPurpose: To follow the changes in the electroretinograms (ERGs in a patient with primary intraocular lymphoma (PIOL who had a complete remission after chemotherapy. Methods: ERGs were recorded in a 41-year-old woman with PIOL during and after complete remission with chemotherapy. The patient was diagnosed with PIOL from both the ocular signs and the medical history of cranial lymphoma.Results: The ERGs were depressed in the subject. The amplitudes of the bright white flash b-waves were smaller than the a-waves, resulting in a “negative type” ERG. Six weeks after the beginning of chemotherapy, the ocular changes had resolved, and the ERGs, although not of the “negative type”, still showed signs that the amplitude had not returned to normal levels.Conclusion: The negative type ERGs indicated that the inner retina had been damaged to a greater extent than the outer retina. In the convalescent stage, when the ocular manifestations were resolved, the ERGs were still not fully recovered. Although only one case was studied, we suggest that ERGs can be used to evaluate and follow patients with a PIOL.Keywords: electroretinogram, primary intraocular lymphoma, uveitis masquerade syndrome

  1. Multifocal Toric Intraocular Lens for Traumatic Cataract in a Child

    Directory of Open Access Journals (Sweden)

    Yanfeng Zeng

    2016-10-01

    Full Text Available A child suffering from traumatic cataract and corneal astigmatism of 2.14 D had a phacoemulsification operation and implantation of a ReSTOR Toric intraocular lens (IOL to correct the astigmatism. The primary outcome measurements were the uncorrected distance visual acuity (UDVA, uncorrected near vision at 40 cm, intraocular pressure, spherical equivalent refraction, residual astigmatism, corneal astigmatism, presence of unusual optical phenomena, and use of spectacles. At 7 months postoperatively, UDVA was maintained between 16/20 and 24/20, near vision was between J1 and J3, residual spherical refraction was 0–0.37 D, and residual refractive cylinder was between 0 and 0.67 D. A multifocal toric IOL can provide the possibility of satisfactory vision for both distant and near conditions without the use of spectacles to meet children’s needs when studying and doing sports. Additionally, binocular vision can be reconstructed. This intervention, therefore, seems to be a satisfactory alternative.

  2. INTRAOCULAR PRESSURE ASYMMETRY: AN INDICATOR FOR GLAUCOMA DIAGNOSIS

    Directory of Open Access Journals (Sweden)

    Rekha R.

    2016-05-01

    Full Text Available AIM To investigate the amount of intraocular pressure asymmetry between fellow eyes in patients with and without primary open angle glaucoma. MATERIALS AND METHODS This was a retrospective case control study conducted at a tertiary care hospital of Central India. A single pre-treatment IOP of the primary open angle glaucoma patients was recorded from the Glaucoma Clinic data from Jan 2013 to Dec 2013. The inter-eye IOP asymmetry of these cases was compared with normal subjects without primary open angle glaucoma (POAG. RESULTS There were 84 (POAG glaucoma patients and 168 control subjects in the study. It was observed that 23.8% patients suffering from glaucoma had an asymmetry of 2 mmHg while 20.23% had no asymmetry. Asymmetry as high as >20 mmHg was also seen in glaucomatous patients. Intraocular pressure asymmetry was a significant factor for having glaucoma (Odds ratio, 18.89%; P<0.001. CONCLUSION Inter-eye asymmetry of IOP is a common finding in patients with POAG. There is a direct relationship between the amount of IOP asymmetry between the fellow eyes and the likelihood of having glaucoma.

  3. Diffractive multifocal intraocular lens interferes with intraoperative view

    Directory of Open Access Journals (Sweden)

    Mami Yoshino

    2010-05-01

    Full Text Available Mami Yoshino1, Makoto Inoue1,2, Nae Kitamura1, Hiroko Bissen-Miyajima11Department of Ophthalmology, Tokyo Dental College Suidobashi Hospital, Tokyo, Japan; 2Kyorin Eye Center, Kyorin University School of Medicine, Tokyo, JapanAbstract: We report an unusual finding during vitreous surgery in an eye implanted with a diffractive multifocal intraocular lens (IOL. A 70-year-old woman reported gradual visual deterioration to 20/40 in the left eye two and a half years after uneventful cataract surgery with implantation of a diffractive multifocal IOL. Funduscopic examination showed an epiretinal membrane (ERM in the left eye. Increased macular traction was believed to cause the visual deterioration. Vitreous surgery with removal of the ERM was performed and triamcinolone acetonide (TA was injected intravitreally to visualize the residual vitreous cortex. Although the ERM was peeled successfully, the ability to focus on the vitreoretinal interface through the IOL required great effort with decreased contrast sensitivity and ghost images of the intravitreal TA crystals. The vision improved to 20/25 4 months postoperatively. Macular surgery can be performed in an eye with a diffractive multifocal IOL; however, decreased contrast sensitivity and ghost images may interfere with the intraoperative view through the diffractive IOL in complicated cases.Keywords: diffractive multifocal intraocular lens, intraoperative view

  4. Elevated Liver Enzymes

    Science.gov (United States)

    Symptoms Elevated liver enzymes By Mayo Clinic Staff Elevated liver enzymes may indicate inflammation or damage to cells in the liver. Inflamed or ... than normal amounts of certain chemicals, including liver enzymes, into the bloodstream, which can result in elevated ...

  5. National Elevation Dataset (NED)

    Data.gov (United States)

    Kansas Data Access and Support Center — The U.S. Geological Survey has developed a National Elevation Database (NED). The NED is a seamless mosaic of best-available elevation data. The 7.5-minute elevation...

  6. Trends in Artificial Intelligence.

    Science.gov (United States)

    Hayes, Patrick

    1978-01-01

    Discusses the foundations of artificial intelligence as a science and the types of answers that may be given to the question, "What is intelligence?" The paradigms of artificial intelligence and general systems theory are compared. (Author/VT)

  7. EVOLUTION THE CONCEPTS OF ROLE OF INTRAOCULAR PRESSURE IN GLAUCOMA PROGRESSION (REVIEW

    Directory of Open Access Journals (Sweden)

    N. I. Kurysheva

    2016-01-01

    Full Text Available The role of elevated intraocular pressure (IOP in the progression of glaucoma optical neuropathy has emphasized repeatedly. The question about the role of elevated IOP as the underlying cause of glaucoma arose in the early 1960s. However, epidemiological studies have questioned the role of IOP as a diagnostic criterion for glaucoma, due to the relatively rare detection the disease among those with ocular hypertension and frequent detection of glaucoma with normal IOP. Multicenter studies determining the role of antihypertensive therapy in the treatment of glaucoma, have shown the importance of reducing IOP: decricing IOP at 1 mm Hg reduced the risk of developing glaucoma on 10-19%. In addition, it was found that the rate of glaucoma progression is very variable. It depends not only on the form of glaucoma, but also on other factors such as the stage of disease and therapy. Swedish study shown normal-tension glaucoma often progressed among the patients with more aggressive treatment such as argon laser trabeculoplasty or trabeculectomies. According to the study’s data, age is the most important risk factor for the progression of normal-tension glaucoma. Such questions as fluctuations in IOP, reduction of retrobulbar blood flow, antihypertensive treatment on the progression of glaucoma are still discussed. Despite the fact that the latter UKGTS multicenter study (2014 showed a decrease in the rate of progression of glaucoma in patients treated with latanoprost, a high percentage of non-treated patients didn’t have disease’s progression. In this regard, the role of IOP as main starting factor in glaucoma pathogenesis is still open.

  8. Artificiality in Social Sciences

    OpenAIRE

    Rennard, Jean-Philippe

    2007-01-01

    This text provides with an introduction to the modern approach of artificiality and simulation in social sciences. It presents the relationship between complexity and artificiality, before introducing the field of artificial societies which greatly benefited from the computer power fast increase, gifting social sciences with formalization and experimentation tools previously owned by "hard" sciences alone. It shows that as "a new way of doing social sciences", artificial societies should undo...

  9. Artificial life and Piaget.

    Science.gov (United States)

    Mueller, Ulrich; Grobman, K H.

    2003-04-01

    Artificial life provides important theoretical and methodological tools for the investigation of Piaget's developmental theory. This new method uses artificial neural networks to simulate living phenomena in a computer. A recent study by Parisi and Schlesinger suggests that artificial life might reinvigorate the Piagetian framework. We contrast artificial life with traditional cognitivist approaches, discuss the role of innateness in development, and examine the relation between physiological and psychological explanations of intelligent behaviour.

  10. Survey of Intraocular Antibiotics Prophylaxis Practice after Open Globe Injury in China.

    Directory of Open Access Journals (Sweden)

    Bingsheng Lou

    Full Text Available To elucidate the Chinese practice of intraocular antibiotics administration for prophylaxis after open globe injury.A cross-sectional questionnaire survey was performed online by scanning a Quickmark (QR code with smartphones at the 20th Chinese National Conference of Ocular Trauma in November 2014.A total of 153 (30.6% of all participators at the conference responded. Of the respondents, 20.9% were routinely administered with prophylactic intraocular injection of antibiotics at the conclusion of the primary eye repair, and 56.9% were used only in cases with high risk of endophthalmitis development. The intraocular route of delivery was mainly included with intracameral injection (47.9% and intravitreal injection (42.0%. Cephalosporins (53.8% and vancomycin (42.0% were the main choices of antibiotic agents, followed by fluoroquinolones (24.3%, and aminoglycosides (13.4%. Only 21.9% preferred a combination of two or more two drugs routinely. In addition, significantly more respondents from the referral eye hospital (92.7% replied using intraocular antibiotics injection for prophylaxis compared to those respondents from the primary hospital (69.4% (p = 0.001, Fisher's exact test.Intraocular antibiotics injection for post-traumatic endophthalmitis prophylaxis is widely used in China. However, the choice of antibiotic agents and the intraocular route of delivery vary. A well-designed clinical trial is needed to establish a standardized protocol of intraocular antibiotics administration for post-traumatic endophthalmitis prophylaxis.

  11. Immediate effect of intravitreal injection of bevacizumab on intraocular pressure

    Directory of Open Access Journals (Sweden)

    Lemos-Reis R

    2014-07-01

    Full Text Available Ricardo Lemos-Reis,1 Nuno Moreira-Gonçalves,1 António B Melo,1 Ângela M Carneiro,1,2 Fernando M Falcão-Reis1,2 1Department of Ophthalmology of Hospital de São João, Porto, Portugal; 2Department of Sense Organs, Faculty of Medicine, University of Porto, Porto, Portugal Purpose: To investigate the immediate effect of intravitreal injection of bevacizumab on intraocular pressure (IOP. Methods: This was a prospective and nonrandomized study. A total of 291 eyes with macular edema or active choroidal neovascularization were submitted to a single 1.25 mg (0.05 mL bevacizumab intravitreal injection. Intraocular pressure was measured with an Icare® tonometer immediately before and after injection in a seated position. The presence of subconjunctival reflux was recorded. The fellow eye served as the control.Results: Mean preoperative IOP was 18.0±5.9 mmHg in the treated eye versus 16.9±6.0 mmHg in the fellow eye. Mean postoperative IOP was 42.1±14.5 mmHg in the treated eye versus 17.5±6.0 mmHg in the fellow eye. The IOP variation was statistically significant in both cases and controls (P<0.001 and P=0.003, respectively, and this increase was higher in cases than in controls (P<0.001. Postoperative IOPs higher than 50 mmHg were achieved in 32.0% of the eyes. Subconjunctival reflux was present in 21.3% and determined a lower IOP rise (P<0.001. Tested variables (glaucoma, phakic status, and sex did not have a statistically significant effect on IOP rise or subconjunctival reflux. Conclusion: IOP increases with intravitreal bevacizumab injection, reaching 50 mmHg or more in about one third of patients. A higher IOP is expected if no subconjunctival reflux occurs. The baseline IOP does not influence the incidence of subconjunctival reflux. The clinical relevance of these facts has yet to be clarified. Keywords: bevacizumab, intraocular pressure, intravitreal injection, Icare®

  12. Results of Iris-Claw Intraocular Lens Implantation in Aphakia

    Directory of Open Access Journals (Sweden)

    Mehmet Tahir Şam

    2014-12-01

    Full Text Available Objectives: To evaluate the visual outcomes and complications of iris-claw intraocular lenses (ICIOL implanted in cases of aphakia or in cataract surgery with insufficient capsule support. Material and Method: In this retrospective study, we reviewed the medical records of 34 eyes of 34 patients who had undergone ICIOL implantation with a minimum follow-up of 12 months in Bucak State Hospital and in a private hospital between November 2007 and November 2012. Results: Twenty-one eyes with complicated cataract accompanied by zonular deficiency, 8 eyes with aphakia, and 5 eyes with dislocated IOL were operated and ICIOL implanted. Mean preoperative BCVA was 1.46±1.05 LogMAR and postoperative BCVA was 0.20±0.21 LogMAR. There was an improvement in visual acuity in 31 eyes of the 34 patients, and 29 of them had a visual acuity better than 6/12 postoperatively. Mean postoperative spherical equivalent (SE was -0.76±0.94 D, and deviation from estimated SE was -0.26±0.94 D. Mean preoperative astigmatism was -1.36±0.77 Cyl D and mean postoperative astigmatism was -0.98±0.82 Cyl D. In second postoperative month, one case had a pupillary block glaucoma due to the closure of peripheral iridotomy, and after ND-YAG laser treatment, intraocular pressure return to normal value. One eye had iris pigment precipitates on the ICIOL in early postoperative period, and in one case, there was a pupillary ovalization. Three months after a cataract surgery, retinal detachment developed in one eye of a patient who had a history of severe ocular trauma; anterior vitrectomy and ICIOL implantation were performed. Visual acuity remained unchanged after a successful pars plana vitrectomy operation. Conclusion: Iris-claw lenses provide fairly good visual outcomes in aphakic eyes without capsular support and in challenging cataract cases with zonular deficiency. They are safe regarding complications when compared to other alternative intraocular lens implantation methods

  13. Optical quality of toric intraocular lens implantation in cataract surgery

    Institute of Scientific and Technical Information of China (English)

    Xian-Wen; Xiao; Jing; Hao; Hong; Zhang; Fang; Tian

    2015-01-01

    AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of Acry Sof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes,T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), residual refractive cylinder and intraocular lens(IOL) axis rotation.Objective optical quality were measured using optical quality analysis system(OQAS Ⅱ, Visiometrics, Spain),included the cutoff frequency of modulation transfer function(MTFcutoff), objective scattering index(OSI),Strehl ratio, optical quality analysis system value(OV)100%, OV 20% and OV 9% [the optical quality analysis system(OQAS) values at contrasts of 100%, 20%, and 9%].RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18 ±0.11 and 0.07 ±0.08 log MAR; the mean residual refractive cylinder was 0.50 ±0.29 D; the mean toric IOL axis rotation was 3.62 ±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV9% were 22.862 ±5.584, 1.80 ±0.84, 0.155 ±0.038, 0.76 ±0.18,0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%,OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different(P >0.05), except the residual refractive cylinder(P <0.05).CONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of Acry Sof toric IOL implantation. Implantation of an Acry Sof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery.

  14. Intraocular inflammation as the main manifestation of Rickettsia conorii infection

    Directory of Open Access Journals (Sweden)

    Orduña A

    2011-09-01

    Full Text Available Archimedes LD Agahan1,3, Jenice Torres1, Graciana Fuentes-Páez1, Hernan Martínez-Osorio1, Antonio Orduña2, Margarita Calonge11Ocular Immunology and Uveitis Unit, Institute of Applied Ophthalmobiology (IOBA, 2Microbiology Department, University of Valladolid, Valladolid, Spain; 3Department of Ophthalmology and Visual Sciences, University of the Philippines, Philippine General Hospital, Manila, PhilippinesObjective: To report the clinical features and management of seven cases of intraocular inflammation caused by Rickettsia infection and review published literature.Methods: Rickettsia conorii or Rickettsia spp. infection was diagnosed based on the following criteria: (1 positive serology according to the European Guidelines, (2 titer normalization after specific treatment, and (3 complete resolution of ophthalmic disease and accompanying symptoms after antibiotic therapy.Results: Seven patients were referred for uveitis of unknown etiology. All came from regions where Mediterranean spotted fever is prevalent. One patient met the European guidelines criteria for Rickettsia spp. infection, while the other six cases met the criteria for R. conorii infection. The main symptoms were visual loss, floaters, eye redness, photophobia, and ocular pain. Predominant ophthalmic signs included vasculitis, choroiditis, vitritis, and macular edema. All patients required antibiotic treatment that resulted in the remission of the infection. Doxycycline was the first choice and the only antibiotic used to treat four patients. One patient needed ciprofloxacin as a second antibiotic after not responding to doxycycline. Two patients had doxycycline as a second antibiotic after not responding primarily to sulfonamides (which had been given after 2–3 days of doxycycline gastric intolerance; one of these patients needed ciprofloxacin as a third antibiotic.Conclusion: Intraocular inflammation can occur as the main manifestation of Rickettsia conorii or Rickettsia spp

  15. Magnetic resonance imaging diagnosis of intraocular lenses. Die kernspintomographische Diagnostik der Hinterkammerlinse

    Energy Technology Data Exchange (ETDEWEB)

    Tosch, U. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany)); Bleckmann, H. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany)); Kaczmarek, U. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany))

    1994-09-01

    Intraocular lenses were investigated by MRI to obtain information about the quality of this method. In experimental studies, seven lenses of between 0 and 30 diopters were visualized. By MRI it was possible to differentiate the various diameters of lenses. It was not possible to discriminate the material of the intraocular lenses. After these first studies the eyes of two corpses and eight patients were investigated. Because of the resolution of MRI it was possible to tell the diopter of implanted lenses. However, by use of MRI in the regular position, a tilting or decentration of the intraocular lens was demonstrated. (orig.)

  16. Bionic intraocular lens with variable focus and integrated structure

    Science.gov (United States)

    Liang, Dan; Wang, Xuan-Yin; Du, Jia-Wei; Xiang, Ke

    2015-10-01

    This paper proposes a bionic accommodating intraocular lens (IOL) for ophthalmic surgery. The designed lens has a solid-liquid mixed integrated structure, which mainly consists of a support ring, elastic membrane, rigid lens, and optical liquid. The lens focus can be adjusted through the deformation of the lens front surface when compressed. The integrated structure of the IOL is presented, as well as a detailed description of the lens materials and fabrication process. Images under different radial pressures are captured, and the lens deformation process, accommodating range, density, and optical property are analyzed. The designed lens achieves a 14.6 D accommodating range under a radial pressure of 51.4 mN and a 0.24 mm alteration of the lens outer radius. The deformation property of the lens matches well with the characteristic of the eye and shows the potential to help patients fully recover their vision accommodation ability after the cataract surgery.

  17. The accute effects of resistance exercise on intraocular pressure

    Directory of Open Access Journals (Sweden)

    Vieira Geraldo Magela

    2003-01-01

    Full Text Available PURPOSE: To study intraocular pressure (IOP variations in healthy volunteers after weight lifting, in the supine position. METHODS: A descriptive study was designed. Thirty-four individuals were preselected for this study, and a group of 25 volunteers fulfilled the inclusion criteria for joining the initial phase of this research. All of them were healthy without glaucoma. They were asked to lift an 85% top load in the supine position for 8 times. IOP was measured before and after the exercise. Student's t test was used to analyze the IOP variations. RESULTS: A small, but significant IOP decrease (1.61 mmHg was obtained after exposing 25 individuals (49 eyes to a specific physical effort. CONCLUSIONS: After a session of weight lifting in the supine position with 85% top load for 8 repetitions, there is a small, but significant IOP decrease.

  18. Opacificação tardia de lente intra-ocular de polimetilmetacrilato (PMMA: relato de caso Late opacification of a polymethylmethacrylate (PMMA intraocular lens: case report

    Directory of Open Access Journals (Sweden)

    Otacílio de Oliveira Maia Júnior

    2005-10-01

    Full Text Available O implante das lentes intra-oculares foi grande avanço na reabilitação visual de pacientes submetidos à cirurgia de extração da catarata. Contudo, os materiais utilizados na fabricação destas lentes, apesar de terem boa biocompatibilidade, são passíveis de alterações posteriores ao implante. No presente estudo, os autores relatam um caso raro de opacificação tardia de lente de polimetilmetacrilato, material inerte e bem tolerado intra-ocularmente, discutindo aspectos importantes no manejo desta complicação, bem como indicação de explante e substituição da lente.The use of intraocular lenses was a great advance in visual recovery after cataract surgery. Although usually with good biocompatibility, some alterations in the intraocular lens material may occur after implantation. Polymethylmethacrylate was the first intraocular lens material to be used on a large scale and assumed to be inert and well-tolerated. We present a rare case of late opacification of a polymethylmethacrylate lens, discussing important aspects of its management such as the indication for intraocular lens exchange.

  19. Intraocular penetration of sequentially instilled topical moxifloxacin, gatifloxacin, and levofloxacin

    Directory of Open Access Journals (Sweden)

    Koji Sugioka

    2009-10-01

    Full Text Available Koji Sugioka1, Masahiko Fukuda1, Shohei Komoto1, Motoki Itahashi1, Masakazu Yamada2, Yoshikazu Shimomura11Department of Ophthalmology, Kinki University School of Medicine, Osaka-Sayama City, Osaka, Japan; 2Division for Vision Research, National Institute of Sensory Organs, National Tokyo Medical Center, Tokyo, JapanPurpose: The objective of the study was to compare the intraocular penetration levels of the newer fluoroquinolones, moxifloxacin, gatifloxacin, and levofloxacin in the rabbit’s cornea, aqueous humor, and conjunctiva after topical instillation.Methods: 0.5% moxifloxacin, 0.3% gatifloxacin, and 0.5% levofloxacin were instilled in random sequence in both eyes of nine New Zealand White rabbits at two-minute intervals. Instillation was repeated every 15 minutes for a total of three drops of each fluoroquinolone per eye. Three additional animals had only moxifloxacin instilled bilaterally using the same schedule. Sixty minutes after the final instillation, the rabbits were sacrificed for determination of corneal, aqueous humor, and conjunctival fluoroquinolone concentrations using highperformance liquid chromatography.Results: Moxifloxacin achieved significantly higher concentrations than levofloxacin and gatifloxacin in the cornea (P = 0.0102 and P = 0.0006, respectively, aqueous humor (P = 0.0015 and P < 0.0001, respectively, and conjunctiva (P = 0.0191 and P = 0.0236, respectively. Conclusions: 0.5% moxifloxacin eyedrops provided superior intraocular penetration in rabbits’ eyes compared with the two other fluoroquinolones, 0.5% levofloxacin and 0.3% gatifloxacin.Keywords: fluoroquinolone, gatifloxacin, levofloxacin, moxifloxacin, penetration, rabbit

  20. A previsibilidade biométrica nas lentes intra-oculares multifocais Biometric predictability in multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Augusto Cézar Lacava

    2007-08-01

    Full Text Available OBJETIVO: Apresentar a previsibilidade biométrica, avaliando a refração pós-operatória e acuidade visual (AV, em olhos submetidos a implante de lente intra-ocular multifocal. MÉTODOS: Estudo retrospectivo em 88 olhos de 50 pacientes, submetidos à facoemulsificação com implante de lentes multifocais, de três marcas comerciais ReSTOR, ReZoom e Tecnis. No exame biométrico foram utilizados a biometria óptica ou biometria por interferometria de baixa coerência, associada ao uso de tomógrafo de segmento anterior e à fórmula biométrica Holladay II. Com a refração pós-operatória, acuidade visual e a dioptria da LIO implantada, segundo a fórmula Holladay II, calculamos o valor da lente intra-ocular (LIO a ser implantada caso utilizássemos as fórmulas SRKT e Haigis. Os resultados foram avaliados por métodos estatísticos. RESULTADOS: Todos os olhos obtiveram AV igual ou maior a 20/40 e J3 sem correção. As fórmulas Holladay II, SRKT e Haigis apresentaram performance semelhante em todos os grupos de olhos. CONCLUSÃO: A utilização de novas tecnologias, como a biometria óptica e fórmulas de última geração, favorecem a obtenção do resultado refracional almejado com grande previsibilidade.PURPOSE: To present biometric predictability, evaluating postoperative refraction and visual acuity in eyes submitted to multifocal intraocular lens implantation. METHODS: Retrospective study in 88 eyes of 50 patients, submitted to phacoemulsification with multifocal lens implant of three commercial brands: ReSTOR, ReZoom and Tecnis. For biometric examination were used: optic biometry associated to the use of tomography of anterior segment and Holladay II biometric formula. With postoperative refraction, visual acuity and implanted IOL, according to Holladay II formula, we calculated the value of IOL to be implanted in case we used SRKT and Haigis formulas. The results were evaluated according to statistical methods. RESULTS: All eyes

  1. Posterior Segment Intraocular Foreign Body: Extraction Surgical Techniques, Timing, and Indications for Vitrectomy

    Directory of Open Access Journals (Sweden)

    Dante A. Guevara-Villarreal

    2016-01-01

    Full Text Available Ocular penetrating injury with Intraocular Foreign Body (IOFB is a common form of ocular injury. Several techniques to remove IOFB have been reported by different authors. The aim of this publication is to review different timing and surgical techniques related to the extraction of IOFB. Material and Methods. A PubMed search on “Extraction of Intraocular Foreign Body,” “Timing for Surgery Intraocular Foreign Body,” and “Surgical Technique Intraocular Foreign Body” was made. Results. Potential advantages of immediate and delayed IOFB removal have been reported with different results. Several techniques to remove IOFB have been reported by different authors with good results. Conclusion. The most important factor at the time to perform IOFB extraction is the experience of the surgeon.

  2. The Experimental Study on Implantation of Intraocular Lens in Different Animals

    Institute of Scientific and Technical Information of China (English)

    WANGGui-qin; PENGXiu-jun; GUHan-qing

    2004-01-01

    To prevent the complications in cataract surgeries, the eyes of rabbits and monkeys were implanted with intraocular lens for 360 days. Methods: The eyes of the rabbits were performed with phacoemulsification and soft intraocular lens implantation. The eyes of the monkeys were performed with extracapsular cataract extraction and hard intraocular lens implantation. Results: The postoperative reactions included corneal edema, anterior chamber exudation, posterior capsule opacification and so on. The complications in the eyes of the rabbits were more than that in the eyes of the monkeys. Conclusion: The different postoperative reactions happened in different animals. In clinical the choice of the operative method and intraocular lens depended on the case in order to acquire the best sight.

  3. New Management of Malignant Glaucoma by Phacoemulsification with Posterior Chamber Foldable Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    GeJian; GuoY

    1999-01-01

    Objective:To investigate the feasibility of phacoemulsification with posterior chamber foldable intraocular lens implantation in the management of malignant glaucoma. Patients and Methods:Fourteen patients with malignant glaucoma diagnosed in the Department of Glaucoma were enrolled in the study.12 patients developed malignant glaucoma after filtration surgery.1 developed after peripheral iridectomy.1 patient developed malignant glaucoma without any clear cause.Cataract phacoemulsification was performed.Posterior chamber intraocular foldable lens was implanted in 10 cases of patients.Results:All 14 patients were cured wiht normal intraocular pressure,normal anterior chamber depth and increased visual acuity.Conclusion:Phacoemulsification with posterior chamber foldable intraocular lens implantation is a good alternative in treating malignant glaucoma.

  4. Intraocular Foreign Body. A Case Presentation Cuerpo extraño intraocular. Presentación de un caso

    Directory of Open Access Journals (Sweden)

    Inés Zamora Galindo

    2012-05-01

    Full Text Available

    Eye trauma is a common cause of visual impairment, mainly of monocular blindness in 33 to 40% of cases. The case of a 40 years old female patient of rural origin, who attended Ophthalmology consultation at the Dr. Gustavo Aldereguía Lima General University Hospital because of blurry vision in her right eye three months after a trauma, is presented. An accurate medical record, ophthalmologic examination and appropriate diagnostic methods allowed identifying an intraocular foreign body. The patient underwent surgery and evolved favorably. Her best corrected visual acuity is 0.7 in the right eye and 1.0 in the left eye.

    Los traumatismos oculares son una causa común de deficiencia visual, principalmente de ceguera monocular en el 33 al 40 % de los casos. Se presenta el caso de un paciente de 40 años y procedencia rural, que acudió a consulta de Oftalmología del Hospital General Universitario Dr. Gustavo Aldereguía Lima por presentar visión borrosa del ojo derecho, tres meses después de haber sufrido un traumatismo. Una correcta anamnesis, examen oftalmológico y métodos diagnósticos adecuados lograron la identificación de un cuerpo extraño intraocular. El paciente fue sometido a cirugía y evolucionó favorablemente; su agudeza visual mejor corregida es de 0,7 en el ojo derecho y de 1,0 en el izquierdo.

  5. Implanting two posterior chamber intraocular lenses in a case of microphthalmos.

    Science.gov (United States)

    Gayton, J L; Sanders, V N

    1993-11-01

    A 31-year-old male with bilateral microphthalmos and a history of severe refractive amblyopia presented with early nuclear sclerosis. Intraocular lens calculations determined the patient would need about a 46.0 diopter power intraocular lens in both eyes to achieve satisfactory vision postoperatively. When no manufacturer could or was willing to make such a high-power lens, we chose to implant two lenses in each eye. The patient is satisfied with his postoperative vision and overall outcome.

  6. New two-point scleral-fixation technique for foldable intraocular lenses with four hollow haptics.

    Science.gov (United States)

    Liu, He-Ting; Jiang, Zheng-Xuan; Tao, Li-Ming

    2016-01-01

    The study was to report a new two-point scleral-fixation technique for foldable intraocular lenses with four haptics. Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera flaps at two opposite points. The postoperative best-corrected visual acuities (BCVAs) of all patients were significantly better than their preoperative BCVA. The results demonstrate that two-point, scleral fixations of foldable, intraocular lenses might be practicable and effective.

  7. Influence of untreated chronic plastic iridocyclitis on intraocular pressure in leprosy patients.

    OpenAIRE

    Karaçorlu, M A; Cakiner, T; Saylan, T

    1991-01-01

    The intraocular pressures of a total of 286 eyes of patients with lepromatous and borderline lepromatous leprosy who never had regular ophthalmological care or local eye treatment were measured. The patients were categorised according to the type of leprosy they had, and the eyes were categorised as without or with chronic plastic iridocyclitis. In patients with lepromatous and borderline lepromatous types of leprosy the intraocular pressure was significantly lower in eyes with chronic plasti...

  8. Implante de lente intra-ocular dobrável acrílica em crianças Acrylic foldable intraocular lens implantation in children

    Directory of Open Access Journals (Sweden)

    Antonio Jordão Jr.

    2000-04-01

    Full Text Available Objetivos: Avaliar o uso de lentes intra-oculares dobráveis de acrílico na correção da afacia infantil. Métodos: Dez olhos de 10 pacientes com idades entre 3 e 9 anos portadores de catarata infantil foram operados e receberam o implante de lente intra-ocular dobrável de acrílico. Os pacientes foram acompanhados por um período que variou de 6 a 20 meses. Resultados: Após a medida da acuidade visual de todos no último retorno, encontramos uma melhora significativa em cinco pacientes. Em nenhum dos casos houve opacificação da cápsula posterior no período observado ou qualquer outra complicação pós-operatória. Conclusão: Apesar da pequena casuística, os resultados sugerem que o uso de lentes intra-oculares acrílicas proporciona a manutenção da transparência do eixo visual a curto e médio prazos.Purpose: To evaluate the results of the implantation of acrylic foldable intraocular lenses in children. Methods: Ten eyes from 10 children aged 3 to 9 years with infantile cataracts were operated and received an acrylic intraocular lens implantation. Follow-up ranged from 6 to 20 months after surgery. Results: The patients had their visual acuity measured at the last visit and a significant improvement in all but one patient was found. There was no posterior capsule opacification or any other surgical complication in this period. Conclusions: Although the number of cases is small, the results suggest that the use of acrylic intraocular lens provides a very good transparency of the visual axis in the short and medium term after surgery.

  9. A case of Alagille syndrome complicated by intraocular lens subluxation and rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Fukumoto M

    2013-07-01

    Full Text Available Masanori Fukumoto, Tsunehiko Ikeda, Tetsuya Sugiyama, Mari Ueki, Takaki Sato, Eisuke Ishizaki Department of Ophthalmology, Osaka Medical College, Takatsuki City, Japan Abstract: This case report describes a case of Alagille syndrome with developing intraocular lens subluxation and rhegmatogenous retinal detachment 4 years after cataract surgery. A 15-year-old female patient with Alagille syndrome-associated cataracts in both eyes underwent phacoemulsification aspiration and intraocular lens implantation. Four years postoperative, intraocular lens subluxation developed in her left eye. For treatment, extraction of the dislocated intraocular lens, anterior vitrectomy, and intraocular lens fixation was performed. Three weeks later, the patient developed rhegmatogenous retinal detachment, which was well-treated by pars plana vitrectomy. Cataract surgery needs to be performed carefully in patients with Alagille syndrome due to the weakness of the zonule of Zinn. Careful postoperative observation is necessary for patients with Alagille syndrome who have undergone intraocular surgery in order to facilitate early detection of a possible rhegmatogenous retinal detachment. Keywords: Alagille syndrome, cataract, retina, surgery

  10. Effect of phacoemulsification, intraocular lens implantation, and trabeculectomy on angle-closure glaucoma merged with cataract

    Institute of Scientific and Technical Information of China (English)

    Qun Wu; Li-Li Hao; Wen-Xuan Tao; Chun-Xiang Liu

    2016-01-01

    Objective:To explore the clinical effect of phacoemulsification, intraocular lens implantation, and trabeculectomy in the treatment of angle-closure glaucoma merged with cataract. Methods:A total of 80 patients with angle-closure glaucoma merged with cataract who were admitted in our hospital from May, 2015 to May, 2016 were included in the study and randomized into the observation group and the control group. The patients in the control group were given phacoemulsification and intraocular lens implantation. On this basis, the patients in the observation group were given trabeculectomy. The vision, intraocular pressure, central anterior chamber depth, and visual field before operation, 1 week, 1 month, and 3 months after operation in the two groups were detected.Results: In the control group, 1 month after operation, while in the observation group, 1 week after operation, the vision was significantly improved, the intraocular pressure was significantly reduced, the central anterior chamber depth was significantly increased, and the average visual field defect value and average standard deviation value were significantly improved when compared with before operation (P<0.05); moreover, the improved degree in the observation group was significantly superior to that in the control group (P<0.05).Conclusions:Phacoemulsification, intraocular lens implantation, and trabeculectomy in the treatment of angle-closure glaucoma merged with cataract can effectively increase the central anterior chamber depth, reduce the intraocular pressure, and improve the vision; therefore, it deserves to be widely recommended in the clinic.

  11. Intraocular pressure variations during zygomatic fracture reduction and fixation: a clinical study.

    LENUS (Irish Health Repository)

    Murray, Dylan J

    2012-02-03

    BACKGROUND: The reduction of midface fractures has been associated with the rare but devastating complication of blindness. An increase in intraocular pressure is important in the mechanism of blindness in this setting. In this study, the authors assessed the intraocular pressure in patients who underwent zygomatic fracture reduction (with or without fixation). METHODS: Using applanation tonometry, 29 patients underwent intraocular pressure measurements before, during, and after fracture fixation. The contralateral pressures were measured and used as the control. RESULTS: There were 29 patients with a mean age of 35 years, and the mean time to surgery was 5 days. Preoperatively, all patients had normal intraocular pressures and normal visual acuity. All patients underwent a Gillies lift and 18 patients required open reduction and fixation of the frontozygomatic suture (n = 4) or the infraorbital margin (n = 2), and the remainder (n = 12) required fixation of both points. There was no statistically significant increase in the intraocular pressures following the reduction of uncomplicated zygomatic fractures. Statistically significant pressure reductions were noted immediately after reduction and fixation. CONCLUSIONS: The surgical reduction of uncomplicated zygomatic fractures has no adverse effect on the intraocular pressure. It is the authors\\' opinion that adjunctive measures to reduce the pressures are unnecessary.

  12. Effect of lateral temporal corneal incision for intraocular pressure and tear film stability in cataract patients

    Directory of Open Access Journals (Sweden)

    Ying Wang

    2017-02-01

    Full Text Available AIM: To investigate therapeutic effect of lateral temporal corneal incision phacoemulsification combined with intraocular lens(IOLon cataract and its effect on intraocular pressure(IOPand tear film. METHODS: The clinical data of patients with cataract who received treatment in our hospital from March 2014 to December 2015 were retrospectively analyzed. According to the location of the incision, they were divided into temporal corneal incision group and upper corneal incision group. We observed the incidence of complications of the two groups, compared the intraocular pressure, visual acuity, refraction and tear film break-up time of the two groups before and after surgery. RESULTS: The operation time and postoperative pain score of the two groups had no significant difference(P>0.05. The IOP and visual acuity between the two groups before operation had no significant difference(P>0.05. At the intraocular pressure of the two groups was lower than that before operation, and the visual acuity was higher than before operation, and the changes of the anterior lateral incision group were more obvious(PPCONCLUSION: The temporal corneal incision phacoemulsification combined with intraocular lens implantation has a good therapeutic effect on cataract patients, can effectively improve the intraocular pressure and tear film stability, improve eye function, promote the recovery of the body after surgery.

  13. Artificial cognition architectures

    CERN Document Server

    Crowder, James A; Friess, Shelli A

    2013-01-01

    The goal of this book is to establish the foundation, principles, theory, and concepts that are the backbone of real, autonomous Artificial Intelligence. Presented here are some basic human intelligence concepts framed for Artificial Intelligence systems. These include concepts like Metacognition and Metamemory, along with architectural constructs for Artificial Intelligence versions of human brain functions like the prefrontal cortex. Also presented are possible hardware and software architectures that lend themselves to learning, reasoning, and self-evolution

  14. Iowa Bedrock Surface Elevation

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — This Digital Elevation Model (DEM) of the bedrock surface elevation in Iowa was compiled using all available data, principally information from GEOSAM, supplemented...

  15. Posture change and intraocular pressure fluctuation%体位与眼压

    Institute of Scientific and Technical Information of China (English)

    刘伟; 邢小丽; 季健

    2015-01-01

    Although the pathogenesis of glaucoma is complicated and multifactorial,elevated intraocular pressure (IOP) remains the most important known risk factor.The higher the IOP and the larger the IOP fluctuation,the more damage to the optic nerve.IOP fluctuation can be affected by many factors,such as emotion,exercise and circadian rhythm,etc.Recently,the effects of postural change on IOP fluctuation are receiving more and more attention.This article reviews the effects of different body positions on IOP fluctuation,the effects of surgery,medications and aging on posture-induced IOP fluctuation and the effects of postural change on IOP fluctuation of certain special groups.The possible mechanisms of postureinduced IOP fluctuation are also discussed in this article.%青光眼的发病机制复杂,而眼压是已知的最重要的危险因素.眼压越高,眼压波动越大,青光眼性视神经损害越严重.眼压波动会受到多重因素的影响,如情绪、运动、昼夜节律等.近些年来,体位变化对眼压波动的影响得到越来越多的关注.本文主要综述各种不同体位对眼压的影响,药物和手术、年龄对眼压随体位变化的影响,体位变化对几类特殊人群眼压的影响,并对眼压随体位变化的机制进行了分析探讨.

  16. Identifying the critical factors that influence intraocular pressure using an automated regression tree

    Directory of Open Access Journals (Sweden)

    Nishanee Rampersad

    2017-01-01

    Full Text Available Background: Assessment of intraocular pressure (IOP is an important test in glaucoma. In addition, anterior segment variables may be useful in screening for glaucoma risk. Studies have investigated the associations between IOP and anterior segment variables using traditional statistical methods. The classification and regression tree (CART method provides another dimension to detect important variables in a relationship automatically.Aim: To identify the critical factors that influence IOP using a regression tree.Methods: A quantitative cross-sectional research design was used. Anterior segment variables were measured in 700 participants using the iVue100 optical coherence tomographer, Oculus Keratograph and Nidek US-500 ultrasonographer. A Goldmann applanation tonometer was used to measure IOP. Data from only the right eyes were analysed because of high levels of interocular symmetry. A regression tree model was generated with the CART method and Pearson’s correlation coefficients were used to assess the relationships between the ocular variables.Results: The mean IOP for the entire sample was 14.63 mmHg ± 2.40 mmHg. The CART method selected three anterior segment variables in the regression tree model. Central corneal thickness was the most important variable with a cut-off value of 527 µm. The other important variables included average paracentral corneal thickness and axial anterior chamber depth. Corneal thickness measurements increased towards the periphery and were significantly correlated with IOP (r ≥ 0.50, p ≤ 0.001.Conclusion: The CART method identified the anterior segment variables that influenced IOP. Understanding the relationship between IOP and anterior segment variables may help to clinically identify patients with ocular risk factors associated with elevated IOPs.

  17. ARHGEF12 influences the risk of glaucoma by increasing intraocular pressure.

    Science.gov (United States)

    Springelkamp, Henriët; Iglesias, Adriana I; Cuellar-Partida, Gabriel; Amin, Najaf; Burdon, Kathryn P; van Leeuwen, Elisabeth M; Gharahkhani, Puya; Mishra, Aniket; van der Lee, Sven J; Hewitt, Alex W; Rivadeneira, Fernando; Viswanathan, Ananth C; Wolfs, Roger C W; Martin, Nicholas G; Ramdas, Wishal D; van Koolwijk, Leonieke M; Pennell, Craig E; Vingerling, Johannes R; Mountain, Jenny E; Uitterlinden, André G; Hofman, Albert; Mitchell, Paul; Lemij, Hans G; Wang, Jie Jin; Klaver, Caroline C W; Mackey, David A; Craig, Jamie E; van Duijn, Cornelia M; MacGregor, Stuart

    2015-05-01

    Primary open-angle glaucoma (POAG) is a blinding disease. Two important risk factors for this disease are a positive family history and elevated intraocular pressure (IOP), which is also highly heritable. Genes found to date associated with IOP and POAG are ABCA1, CAV1/CAV2, GAS7 and TMCO1. However, these genes explain only a small part of the heritability of IOP and POAG. We performed a genome-wide association study of IOP in the population-based Rotterdam Study I and Rotterdam Study II using single nucleotide polymorphisms (SNPs) imputed to 1000 Genomes. In this discovery cohort (n = 8105), we identified a new locus associated with IOP. The most significantly associated SNP was rs58073046 (β = 0.44, P-value = 1.87 × 10(-8), minor allele frequency = 0.12), within the gene ARHGEF12. Independent replication in five population-based studies (n = 7471) resulted in an effect size in the same direction that was significantly associated (β = 0.16, P-value = 0.04). The SNP was also significantly associated with POAG in two independent case-control studies [n = 1225 cases and n = 4117 controls; odds ratio (OR) = 1.53, P-value = 1.99 × 10(-8)], especially with high-tension glaucoma (OR = 1.66, P-value = 2.81 × 10(-9); for normal-tension glaucoma OR = 1.29, P-value = 4.23 × 10(-2)). ARHGEF12 plays an important role in the RhoA/RhoA kinase pathway, which has been implicated in IOP regulation. Furthermore, it binds to ABCA1 and links the ABCA1, CAV1/CAV2 and GAS7 pathway to Mendelian POAG genes (MYOC, OPTN, WDR36). In conclusion, this study identified a novel association between IOP and ARHGEF12.

  18. Phase-Contrast Micro-Computed Tomography Measurements of the Intraocular Pressure-Induced Deformation of the Porcine Lamina Cribrosa.

    Science.gov (United States)

    Coudrillier, Baptiste; Geraldes, Diogo M; Vo, Nghia T; Atwood, Robert; Reinhard, Christina; Campbell, Ian C; Raji, Yazdan; Albon, Julie; Abel, Richard L; Ethier, C Ross

    2016-04-01

    The lamina cribrosa (LC) is a complex mesh-like tissue in the posterior eye. Its biomechanical environment is thought to play a major role in glaucoma, the second most common cause of blindness. Due to its small size and relative inaccessibility, high-resolution measurements of LC deformation, important in characterizing LC biomechanics, are challenging. Here we present a novel noninvasive imaging method, which enables measurement of the three-dimensional deformation of the LC caused by acute elevation of intraocular pressure (IOP). Posterior segments of porcine eyes were imaged using synchrotron radiation phase contrast micro-computed tomography (PC μCT) at IOPs between 6 and 37 mmHg. The complex trabecular architecture of the LC was reconstructed with an isotropic spatial resolution of 3.2 μm. Scans acquired at different IOPs were analyzed with digital volume correlation (DVC) to compute full-field deformation within the LC. IOP elevation caused substantial tensile, shearing and compressive devformation within the LC, with maximum tensile strains at 30 mmHg averaging 5.5%, and compressive strains reaching 20%. We conclude that PC μCT provides a novel high-resolution method for imaging the LC, and when combined with DVC, allows for full-field 3D measurement of ex vivo LC biomechanics at high spatial resolution.

  19. Classification of intraocular lens and its intraocular biocompatibility%人工晶体分类及其在眼内的生物相容性

    Institute of Scientific and Technical Information of China (English)

    胡莉群

    2009-01-01

    目的:通过手术摘除自身浑浊晶体,植入人工晶体是治疗白内障的惟一有效措施.文章总结人工晶体材料的研究进展,为今后的临床应用和研究提供参考.方法:应用计算机检索1997/2009 Medline数据库、中国期刊网和万方数据库、SpringerLink数据库和ScienceDirect数据库.结果:共有25篇文章符合纳入标准.文章主要从人工晶体的发展现状、分类、生物相容性、人工晶体的并发症和发展趋势进行阐述.人工晶体按照硬度,可以分为硬质人工晶体和软性人工晶体.丙烯酸人工晶体比硅凝胶人工晶体的生物相容性更好.人工晶状体脱位是白内障摘除联合人工晶状体植入术后较常见的并发症之一.注入式人工晶体材料是今后研究的方向.结论:人工晶体植入眼内作为一种异物,机体对此产生反应是机体正常的防御现象.人工晶体材料和设计应充分的考虑人工晶体的生物相容性、术后视功能、调节功能、光保护等方面性能.保证术后的疗效和减少并发症的发生,使白内障患者获得更高质量的视力康复.%OBJECTIVE: The sole effective measure for cataract is replaced the epinephelos lens with intraocular lens. So, in this paper, we summarize the research process of intraocular lens, which can provide a reference for further study. METHODS: Medline, China Journal Net, Wanfang Data, SpringerLink, and ScienceDirect database were computer retrieved from 1997 to 2009. RESULTS: A total of 25 papers were included. All the papers were explained intraocular lens from the aspect of current situation, complication following implantation, and develop tendency. According to hardness, intraocular lens can be divided into hard intraocular lens and soft intraocular lens. Acrylic intraocular lenses showed better biocompatibility than the silicone intraocular lenses. In addition, the common complication following implantation was dislocation of lens. Therefore

  20. Clinical study of customized aspherical intraocular lens implants

    Institute of Scientific and Technical Information of China (English)

    Lie-Xi; Jia; Zhao-Hui; Li

    2014-01-01

    AIM:To compare if there is an improvement in visual functions with age-related cataracts between patients receiving a aspherical intraocular lens(IOL) based on corneal wavefront aberration and patients randomly assigned lenses.METHODS:A total of 124 eyes of 124 patients with age-related cataracts were placed in experimental group and a group receiving randomly assigned(RA) lenses.The experimental group was undergone Pentacam corneal spherical aberration measurement before surgery; the targeted range for residual total spherical aberration after surgery was set to 0-0.3 μm. Patients with a corneal spherical aberration <0.3 μm were implanted with a zero-spherical aberration advanced optics(AO) aspherical IOL and patients with an aberration ≥0.3 μm received a Tecnis Z9003 aspherical lens in experimental group. RA patients were randomly implanted with an AO lens or a Tecnis Z9003 lens. Three months after surgery total spherical aberration, photopic/mesopic contrast sensitivities, photopic/mesopic with glare contrast sensitivities, and logMAR vision were measured.RESULTS:Statistical analysis on logMAR vision showed no significant difference between two groups(P =0.413). The post-surgical total spherical aberration was 0.126 ±0.097 μm and 0.152 ±0.151 μm in the experimental and RA groups, respectively(P =0.12). The mesopic contrast sensitivities at spatial frequencies of 6,12 and 18 c/d in the experimental group were significantly higher than of the RA group(P =0.00; P =0.04;P =0.02). The mesopic with glare contrast sensitivity in the experimental group at a spatial frequency of 18 c/d was also significantly higher vs the RA group(P =0.01).CONCLUSION:Pre-surgical corneal spherical aberration measurement in cataract patients followed bycustomized selection of aspherical IOL implants improved mesopic contrast sensitivities at high spatial frequencies, and thus is a superior strategy compared to the random selection of aspherical intraocular lens implants.

  1. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-01-01

    Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = −0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type

  2. Functionalised polysiloxanes as injectable, in situ curable accommodating intraocular lenses.

    Science.gov (United States)

    Hao, Xiaojuan; Jeffery, Justine L; Wilkie, John S; Meijs, Gordon F; Clayton, Anthony B; Watling, Jason D; Ho, Arthur; Fernandez, Viviana; Acosta, Carolina; Yamamoto, Hideo; Aly, Mohamed G M; Parel, Jean-Marie; Hughes, Timothy C

    2010-11-01

    The aged eye's ability to change focus (accommodation) may be restored by replacing the hardened natural lens with a soft gel. Functionalised polysiloxane macromonomers, designed for application as an injectable, in situ curable accommodating intraocular lens (A-IOL), were prepared via a two-step synthesis. Prepolymers were synthesised via ring opening polymerisation (ROP) of octamethylcyclotetrasiloxane (D(4)) and 2,4,6,8-tetramethylcyclotetrasiloxane (D(4)(H)) in toluene using trifluoromethanesulfonic acid (TfOH) as catalyst. Hexaethyldisiloxane (HEDS) was used as the end group to control the molecular weight of the prepolymers, which were then converted to macromonomers by hydrosilylation of the SiH groups with allyl methacrylate (AM) to introduce polymerisable groups. The resulting macromonomers had an injectable consistency and thus, were able to be injected into and refill the empty lens capsular bag. The macromonomers also contained a low ratio of polymerisable groups so that they may be cured on demand, in situ, under irradiation of blue light, in the presence of a photo-initiator, to form a soft polysiloxane gel (an intraocular lens) in the eye. The pre-cure viscosity and post-cure modulus of the polysiloxanes, which are crucial factors for an injectable, in situ curable A-IOL application, were controlled by adjusting the end group and D(4)(H) concentrations, respectively, in the ROP. The macromonomers were fully cured within 5 min under light irradiation, as shown by the rapid change in modulus monitored by photo-rheology. Ex vivo primate lens stretching experiments on an Ex Vivo Accommodation Simulator (EVAS) showed that the polysiloxane gel refilled lenses achieved over 60% of the accommodation amplitude of the natural lens. An in vivo biocompatibility study in rabbits using the lens refilling (Phaco-Ersatz) procedure demonstrated that the soft gels had good biocompatibility with the ocular tissue. The polysiloxane macromonomers meet the targeted

  3. Artificial life and life artificialization in Tron

    Directory of Open Access Journals (Sweden)

    Carolina Dantas Figueiredo

    2012-12-01

    Full Text Available Cinema constantly shows the struggle between the men and artificial intelligences. Fiction, and more specifically fiction films, lends itself to explore possibilities asking “what if?”. “What if”, in this case, is related to the eventual rebellion of artificial intelligences, theme explored in the movies Tron (1982 and Tron Legacy (2010 trat portray the conflict between programs and users. The present paper examines these films, observing particularly the possibility programs empowering. Finally, is briefly mentioned the concept of cyborg as a possibility of response to human concerns.

  4. Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report

    Directory of Open Access Journals (Sweden)

    Kamiya Kazutaka

    2012-04-01

    Full Text Available Abstract Introduction We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. Case presentation A 53-year-old woman had undergone toric implantable collamer lens implantation three years earlier. After informed consent was obtained, we performed simultaneous toric implantable collamer lens removal and phacoemulsification with toric intraocular lens implantation. Preoperatively, the manifest refraction was 0, -0.5 × 15, with an uncorrected visual acuity of 0.7 and a best spectacle-corrected visual acuity of 0.8. Postoperatively, the manifest refraction was improved to 0, -0.5 × 180, with an uncorrected visual acuity of 1.2 and a best spectacle-corrected visual acuity of 1.5. No vision-threatening complications were observed. Conclusion Toric intraocular lens implantation may be a good surgical option for the correction of spherical and cylindrical errors in eyes with implantable collamer lens-induced cataract and astigmatism.

  5. Onion artificial muscles

    Science.gov (United States)

    Chen, Chien-Chun; Shih, Wen-Pin; Chang, Pei-Zen; Lai, Hsi-Mei; Chang, Shing-Yun; Huang, Pin-Chun; Jeng, Huai-An

    2015-05-01

    Artificial muscles are soft actuators with the capability of either bending or contraction/elongation subjected to external stimulation. However, there are currently no artificial muscles that can accomplish these actions simultaneously. We found that the single layered, latticed microstructure of onion epidermal cells after acid treatment became elastic and could simultaneously stretch and bend when an electric field was applied. By modulating the magnitude of the voltage, the artificial muscle made of onion epidermal cells would deflect in opposing directions while either contracting or elongating. At voltages of 0-50 V, the artificial muscle elongated and had a maximum deflection of -30 μm; at voltages of 50-1000 V, the artificial muscle contracted and deflected 1.0 mm. The maximum force response is 20 μN at 1000 V.

  6. Effect of four different intraocular lenses on posterior capsule opacification

    Institute of Scientific and Technical Information of China (English)

    Rahmi; Duman; Fatih; Karel; Pelin; ?zyol; Can; Ates

    2015-01-01

    AIM: To evaluate the impact of 4 different intraocular lenses(IOLs) on posterior capsule opacification(PCO) by comparing the neodymium: yttrium-aluminum-garnet(Nd:YAG) laser capsulotomy rates.METHODS: This retrospective study included 4970 eyes of 4013 cataract patients who underwent phacoemulsification and IOL implantation between January 2000 and January 2008 by the same surgeon at one clinic. Four different IOLs were assessed. The outcome parameter was the incidence of Nd:YAG laser posterior capsulotomies.· RESULTS: An Nd:YAG laser posterior capsulotomy was performed in 153(3.07%) of the 4970 eyes. The mean follow-up time was 84 mo for all of the IOL groups. The percentage of eyes developing PCO was significantly greater for the acrylic hydrophilic IOLs than for the hydrophobic IOLs, although eyes with acrylic hydrophilic IOLs did not require Nd:YAG laser capsulotomy as soon as eyes with acrylic hydrophobic IOLs. There was no difference between the long-term PCO rates when 1-and 3-piece acrylic hydrophobic IOLs were compared or when IOLs made of the same material but with different haptic angles were compared.· CONCLUSION: In this study, eyes with acrylic hydrophilic IOLs were more likely to develop PCO than those with acrylic hydrophobic IOLs. The lens design(1-piece versus 3-piece and varying haptic angles) did not affect the PCO rate.

  7. Sulcus Fixation of Foldable Intraocular Lenses Guided by Ultrasound Biomicroscopy

    Directory of Open Access Journals (Sweden)

    Shasha Gao

    2015-01-01

    Full Text Available Background. To evaluate the clinical efficacy of suture fixation of foldable intraocular lens (IOL in ciliary sulcus guided by ultrasound biomicroscopy (UBM. Methods. Thirty-five eyes of 32 cases needing suture fixation of foldable IOL in ciliary sulcus in our hospital were collected and divided into two groups: group A and group B. In group A, UBM was performed on 19 eyes of 17 cases before surgery to locate the projection position of ciliary sulcus in iris surface. In group B, the traditional sulcus fixation of IOL was performed on 16 eyes of 15 cases. The inserting position of needles, the haptics position of IOL and the IOL tilt, and decentration were observed by UBM examination 3 months after the surgery. Meanwhile, the vision and contrast sensitivity were analysed. Results. The differences in inserting position of the needle, the IOL tilt and decentration, the ratio of IOL haptics in sulcus, and uncorrected visual acuity were statistically significant (P0.05. Conclusions. Sulcus fixation of foldable IOL aided by UBM can increase the accuracy of IOL haptics implanted into ciliary sulcus and reduce the IOL tilt and decentration.

  8. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Oriel Spierer

    2016-05-01

    Full Text Available A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  9. Reverse Optic Capture to Stabilize a Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Howard V. Gimbel

    2013-09-01

    Full Text Available Purpose: To describe a technique for stabilizing a rotationally unstable toric intraocular lens (IOL. Method: Case report and literature review. Results: Surgical technique and long-term follow-up for a patient who underwent repositioning and stabilization of a mobile 1-piece acrylic toric IOL using reverse optic capture (ROC are described. This patient presented with early, more than 70° off-axis rotation. The IOL was repositioned but was very mobile within the bag and tended to rotate off-axis; hence, it was stabilized in the desired position by capturing the optic through the anterior continuous curvilinear capsulorhexis, leaving the haptics in the bag. The immediate and 2-year postoperative follow-up revealed a stable and on-axis IOL with no visual, refractive or ocular complications. Conclusions: ROC is a useful and safe technique to address the problem of toric IOLs that tend to rotate at the time of surgery or are not stable postoperatively.

  10. Aerobic exercise and intraocular pressure in normotensive and glaucoma patients

    Directory of Open Access Journals (Sweden)

    Chatzibalis Theodosios

    2009-08-01

    Full Text Available Abstract Background With the increasing number of people participating in physical aerobic exercise, jogging in particular, we considered that it would be worth knowing if there are should be limits to the exercise with regard to the intraocular pressure (IOP of the eyes. The purpose of this study is to check IOP in healthy and primary glaucoma patients after aerobic exercise. Methods 145 individuals were subdivided into seven groups: normotensives who exercised regularly (Group A; normotensives in whose right eye (RE timolol maleate 0.5% (Group B, latanoprost 0.005% (Group C, or brimonidine tartrate 0.2% (Group D was instilled; and primary glaucoma patients under monotherapy with β-blockers (Group E, prostaglandin analogues (Group F or combined antiglaucoma treatment (Group G instilled in both eyes. The IOP of both eyes was measured before and after exercise. Results A statistically significant decrease was found in IOP during jogging. The aerobic exercise reduces the IOP in those eyes where a b-blocker, a prostaglandin analogue or an α-agonist was previously instilled. The IOP is also decreased in glaucoma patients who are already under antiglaucoma treatment. Conclusion There is no ocular restriction for simple glaucoma patients in performing aerobic physical activity.

  11. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P.

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful. PMID:27462251

  12. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens.

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  13. Sulcus Fixation of Foldable Intraocular Lenses Guided by Ultrasound Biomicroscopy.

    Science.gov (United States)

    Gao, Shasha; Qin, Tingyu; Wang, Shengnan; Lu, Yong

    2015-01-01

    Background. To evaluate the clinical efficacy of suture fixation of foldable intraocular lens (IOL) in ciliary sulcus guided by ultrasound biomicroscopy (UBM). Methods. Thirty-five eyes of 32 cases needing suture fixation of foldable IOL in ciliary sulcus in our hospital were collected and divided into two groups: group A and group B. In group A, UBM was performed on 19 eyes of 17 cases before surgery to locate the projection position of ciliary sulcus in iris surface. In group B, the traditional sulcus fixation of IOL was performed on 16 eyes of 15 cases. The inserting position of needles, the haptics position of IOL and the IOL tilt, and decentration were observed by UBM examination 3 months after the surgery. Meanwhile, the vision and contrast sensitivity were analysed. Results. The differences in inserting position of the needle, the IOL tilt and decentration, the ratio of IOL haptics in sulcus, and uncorrected visual acuity were statistically significant (P 0.05). Conclusions. Sulcus fixation of foldable IOL aided by UBM can increase the accuracy of IOL haptics implanted into ciliary sulcus and reduce the IOL tilt and decentration.

  14. Soft wearable contact lens sensor for continuous intraocular pressure monitoring.

    Science.gov (United States)

    Chen, Guo-Zhen; Chan, Ion-Seng; Leung, Leo K K; Lam, David C C

    2014-09-01

    Intraocular pressure (IOP) is a primary indicator of glaucoma, but measurements from a single visit to the clinic miss the peak IOP that may occur at night during sleep. A soft chipless contact lens sensor that allows the IOP to be monitored throughout the day and at night is developed in this study. A resonance circuit composed of a thin film capacitor coupled with a sensing coil that can sense corneal curvature deformation is designed, fabricated and embedded into a soft contact lens. The resonance frequency of the sensor is designed to vary with the lens curvature as it changes with the IOP. The frequency responses and the ability of the sensor to track IOP cycles were tested using a silicone rubber model eye. The results showed that the sensor has excellent linearity with a frequency response of ∼8 kHz/mmHg, and the sensor can accurately track fluctuating IOP. These results showed that the chipless contact lens sensor can potentially be used to monitor IOP to improve diagnosis accuracy and treatment of glaucoma.

  15. Intraocular Implants for the Treatment of Autoimmune Uveitis

    Directory of Open Access Journals (Sweden)

    Darren J. Lee

    2015-07-01

    Full Text Available Uveitis is the third leading cause of blindness in developed countries. Currently, the most widely used treatment of non-infectious uveitis is corticosteroids. Posterior uveitis and macular edema can be treated with intraocular injection of corticosteroids, however, this is problematic in chronic cases because of the need for repeat injections. Another option is systemic immunosuppressive therapies that have their own undesirable side effects. These systemic therapies result in a widespread suppression of the entire immune system, leaving the patient susceptible to infection. Therefore, an effective localized treatment option is preferred. With the recent advances in bioengineering, biodegradable polymers that allow for a slow sustained-release of a medication. These advances have culminated in drug delivery implants that are food and drug administration (FDA approved for the treatment of non-infectious uveitis. In this review, we discuss the types of ocular implants available and some of the polymers used, implants used for the treatment of non-infectious uveitis, and bioengineered alternatives that are on the horizon.

  16. Customized computer models of eyes with intraocular lenses

    Science.gov (United States)

    Rosales, P.; Marcos, S.

    2007-03-01

    We compared experimental wave aberrations in pseudophakic eyes with aspheric intraocular lenses (IOLs) to simulate aberrations from numerical ray tracing on customized computer eye models using corneal topography, angle λ, ocular biometry, IOL geometry, and IOL tilt and decentration measured on the same eyes. We found high correlations between real and simulated aberrations even for the eye with only the cornea, and these increased on average when the IOL geometry and position were included. Relevant individual aberrations were well predicted by the complete eye model. Corneal spherical aberration and horizontal coma were compensated by the IOL, and in 58.3% of the cases IOL tilt and decentration contributed to compensation of horizontal coma. We conclude that customized computer eye models are a good representation of real eyes with IOLs and allow understanding of the relative contribution of optical, geometrical and surgically-related factors to image quality. Corneal spherical aberration is reduced by aspheric IOLs, although other corneal high order aberrations are still a major contributor to total aberrations in pseudophakic eyes. Tilt and decentration of the IOLs represent a relatively minor contribution of the overall optical quality of the eye.

  17. Determination of scattering in intraocular lenses by spectrophotometric measurements.

    Science.gov (United States)

    Artigas, José M; Felipe, Adelina; Navea, Amparo; García-Domene, M Carmen; Pons, Álvaro; Mataix, Jorge

    2014-12-01

    This study presents a method for measuring scattering in explanted intraocular lenses (IOLs). Currently, determining scattering in IOLs is usually performed by Scheimpflug cameras and the results are expressed in the units used by this apparatus. The method we propose uses a spectrophotometer and this makes it possible to measure the total transmission of the IOL by using an integrating sphere; the direct transmission is determined by the double-beam mode. The difference between these two transmissions gives a value of the scattering in percentage values of light lost. In addition, by obtaining the spectral transmission curve, information about the most scattered wavelengths is also obtained. The IOL power introduces errors when directly measured, particularly with high powers. This problem can be overcome if a tailor-made cuvette is used that shortens the distance between the IOL and the condensing lens of the spectrophotometer when the IOL powers are below 24 diopters. We checked the effectiveness of this method by measuring the scattering of three explanted IOLs from cornea donors. This method, however, does not make it possible to ascertain whether the scattering measured is caused by surface light scattering or internal light scattering.

  18. Photoacoustic imaging features of intraocular tumors: Retinoblastoma and uveal melanoma

    Science.gov (United States)

    Xu, Guan; Xue, Yafang; Özkurt, Zeynep Gürsel; Slimani, Naziha; Hu, Zizhong; Wang, Xueding; Xia, Kewen; Ma, Teng; Zhou, Qifa; Demirci, Hakan

    2017-01-01

    The purpose of this study is to examine the capability of photoacoustic (PA) imaging (PAI) in assessing the unique molecular and architectural features in ocular tumors. A real-time PA and ultrasonography (US) parallel imaging system based on a research US platform was developed to examine retinoblastoma in mice in vivo and human retinoblastoma and uveal melanoma ex vivo. PA signals were generated by optical illumination at 720, 750, 800, 850, 900 and 950 nm delivered through a fiber optical bundle. The optical absorption spectra of the tumors were derived from the PA images. The optical absorption spectrum of each tumor was quantified by fitting to a polynomial model. The microscopic architectures of the tumors were quantified by frequency domain analysis of the PA signals. Both the optical spectral and architectural features agree with the histological findings of the tumors. The mouse and human retinoblastoma showed comparable total optical absorption spectra at a correlation of 0.95 (p<0.005). The quantitative PAI features of human retinoblastoma and uveal melanoma have shown statistically significant difference in two tailed t-tests (p<0.05). Fully compatible with the concurrent procedures, PAI could be a potential tool complementary to other diagnostic modalities for characterizing intraocular tumors. PMID:28231293

  19. Hypobaric Hypoxia: Effects on Intraocular Pressure and Corneal Thickness

    Directory of Open Access Journals (Sweden)

    Marcella Nebbioso

    2014-01-01

    Full Text Available Objective. The purpose of this study focused on understanding the mechanisms underlying ocular hydrodynamics and the changes which occur in the eyes of subjects exposed to hypobaric hypoxia (HH to permit the achievement of more detailed knowledge in glaucomatous disease. Methods. Twenty male subjects, aged 32±5 years, attending the Italian Air Force, were enrolled for this study. The research derived from hypobaric chamber, using helmet and mask supplied to jet pilotes connected to oxygen cylinder and equipped with a preset automatic mixer. Results. The baseline values of intraocular pressure (IOP, recorded at T1, showed a mean of 16±2.23 mmHg, while climbing up to 18,000 feet the mean value was 13.7±4.17 mmHg, recorded at T2. The last assessment was performed returning to sea level (T4 where the mean IOP value was 12.8±2.57 mmHg, with a significant change (P<0.05 compared to T1. Pachymetry values related to corneal thickness in conditions of hypobarism revealed a statistically significant increase (P<0.05. Conclusions. The data collected in this research seem to confirm the increasing outflow of aqueous humor (AH in the trabecular meshwork (TM under conditions of HH.

  20. Macroglobulinemia de Waldenström com hemorragia intra-ocular Waldenström's macroglobulinaemia with intraocular hemorrhage

    Directory of Open Access Journals (Sweden)

    João J. Nassaralla Júnior

    2006-12-01

    Full Text Available O objetivo deste trabalho é relatar um caso de macroglobulinemia de Waldenström com envolvimento retiniano e da circulação coroidiana, com boa resposta ao tratamento. O desenho é um caso controle intervencional. Um homem de 47 anos foi encaminhado para o serviço de hematologia para avaliação de anemia e linfadenopatia inguinal. O diagnóstico de macroglobulinemia de Waldenström foi feito com base nos achados clínicos e laboratoriais. O paciente desenvolveu hemorragia intra-ocular sem associação com hipertensão e com fatores de coagulação normais. Exame fundoscópico revelou retardamento na circulação coriorretiniana, microaneurismas, e telangiectasias no pólo posterior. Angiografia fluorescente demonstrou o prolongamento do tempo da circulação coroidiana, tempo de trânsito arteriovenoso também prolongado, e áreas de não perfusão capilar. Estes resultados foram acompanhados por uma elevação acentuada da IgM. A maioria dos achados oculares foi revertida com a plasmaférese. A macroglobulinemia de Waldenström pode envolver a retina e a circulação coroidiana, porém pode ser reversível com o tratamento apropriado.The aim of this work is to report a case of Waldenström's Macroglobulinaemia involving both retinal and choroidal circulation that resolved after treatment. The design is an interventional case report. A 47-year old male was admitted for evaluation of anaemia, and groin lymphadenopathy. A diagnosis of Waldenström's macroglobulinaemia was made based on clinical and laboratory findings. The patient developed intraocular hemorrhage without associated hypertension and with normal coagulation profile. A funduscopic examination revealed marked dilation and beading of the venous system, microaneurysms, and telangiectatic capillary beds in the posterior pole. A fluorescein angiography showed delayed choroidal filling, prolonged arteriovenous transit time and areas of capillary non-perfusion. These findings were

  1. Artificial intelligence in medicine.

    Science.gov (United States)

    Ramesh, A. N.; Kambhampati, C.; Monson, J. R. T.; Drew, P. J.

    2004-01-01

    INTRODUCTION: Artificial intelligence is a branch of computer science capable of analysing complex medical data. Their potential to exploit meaningful relationship with in a data set can be used in the diagnosis, treatment and predicting outcome in many clinical scenarios. METHODS: Medline and internet searches were carried out using the keywords 'artificial intelligence' and 'neural networks (computer)'. Further references were obtained by cross-referencing from key articles. An overview of different artificial intelligent techniques is presented in this paper along with the review of important clinical applications. RESULTS: The proficiency of artificial intelligent techniques has been explored in almost every field of medicine. Artificial neural network was the most commonly used analytical tool whilst other artificial intelligent techniques such as fuzzy expert systems, evolutionary computation and hybrid intelligent systems have all been used in different clinical settings. DISCUSSION: Artificial intelligence techniques have the potential to be applied in almost every field of medicine. There is need for further clinical trials which are appropriately designed before these emergent techniques find application in the real clinical setting. PMID:15333167

  2. Electrochemical lysis at the stage of endoresection for large posterior intraocular tumors

    Directory of Open Access Journals (Sweden)

    Yu. A. Belyy

    2012-01-01

    Full Text Available Purpose: to design the new combined technique of endoresection with intraoperative intraocular electrochemical lysis at the tumor destruction stage for large posterior intraocular tumors.Methods: 3 patients (3 eyes with large choroidal melanomas t3N0M0 (tumor thickness — 8-10 mm, base diameter — 13-15 mm, juxtapapillary localization. Mean age was 55.4 years old. Endoresection with intraoperational intraocular electrochemical lysis of the tumor was performed. Electrochemical lysis was performed with use of the technical unit ECU 300 (Soering, Germany and the original method of combined intratumoral positioning of two platinum electrodes: anode and cathode.Results: the tumor was removal completely in all 3 cases. the anatomical retinal reattachment was reached in all patients. Sclera was safe in all 3 cases. Visual acuity was not changed (NLP. At the place of the removal tumor a surgical choroidal coloboma without pigmentation all over scleral bed and periphery was shown in all cases in distant postoperative period (from 1.5 to 3 years. No local recurrences or metastasis were revealed in all patients.Conclusion: Further investigations in clinical group are necessarily to determinate the real possibilities of the combined method and the indications for endoresection with intraoperative intraocular electrochemical lysis for large intraocular tumors. 

  3. De stille elever

    DEFF Research Database (Denmark)

    Winther-Lindqvist, Ditte Alexandra

    2012-01-01

    Det er blevet en afgørende samværskompetence i uddannelsessystemet at stå aktivt frem og deltage verbalt i skoleklassens liv både fagligt og socialt. Men ikke alle elever deltager lige villigt verbalt i plenum. Artiklen handler om de stille elever og konsekvenserne af stillehed i skolen. Det...... foreslås at skolesystemet sanktionerer ældre elever hårdere for stillehed end yngre elever og det forklares med at skolelivet også er en kultivering henimod elevhed som social identitet og denne er der forventning om at eleverne mestrer i udskolingen....

  4. Effect of lens status on intraocular pressure in siliconized eyes

    Directory of Open Access Journals (Sweden)

    Mohalhal AA ,El Shazly MI ,Ghalwash DA

    2012-02-01

    Full Text Available Ahmed A Mohalhal, Malak I El Shazly, Dalia A GhalwashKasr El Aini Hospital, Cairo University, Cairo, EgyptPurpose: To evaluate the effect of lens status on intraocular pressure (IOP in siliconized eyes and also on the emulsification of silicone oil.Patients and methods: A total of 31 eyes of 31 patients with retinal detachment were operated on with pars plana vitrectomy and silicone oil injection: 16 phakic (Group A and 15 pseudophakic (Group B. During the 6-month follow-up period, IOP was measured: 1 day postoperative, then at 1 week, 1 month, 2 months, 3 months, and 6 months postoperative. At the end of the follow-up period, gonioscopy was carried out to check emulsified silicone at the anterior chamber angle and also the presence of emulsified silicone on the back of the cornea when the patient was lying down.Results: There was no significant difference between both groups until the first week (P value = 0.15. Starting from the first month, the difference was statistically significant, with mean IOPs in Groups A and B of 14.9 mmHg and 18.2 mmHg, respectively, up to the sixth month (P value = 0.002, with a mean IOP in Groups A and B of 14.4 mmHg and 19.4 mmHg, respectively. Emulsified silicone was clinically stated in twelve cases (80% in Group B and in three cases (19% in Group A.Conclusion: There is a higher incidence of increased IOP and emulsification of silicone oil in pseudophakic eyes than in phakic eyes.Keywords: vitrectomy, siliconized eyes, emulsification, lens status

  5. Psychophysical Vision Simulation of Diffractive Bifocal and Trifocal Intraocular Lenses

    Science.gov (United States)

    Brezna, Wolfgang; Lux, Kirsten; Dragostinoff, Nikolaus; Krutzler, Christian; Plank, Nicole; Tobisch, Rainer; Boltz, Agnes; Garhöfer, Gerhard; Told, Reinhard; Witkowska, Katarzyna; Schmetterer, Leopold

    2016-01-01

    Purpose The visual performance of monofocal, bifocal, and trifocal intraocular lenses was evaluated by human individuals using a vision simulator device. This allowed investigation of the visual impression after cataract surgery, without the need actually to implant the lenses. Methods The randomized, double-masked, three-way cross-over study was conducted on 60 healthy male and female subjects aged between 18 and 35 years. Visual acuity (Early Treatment Diabetic Retinopathy Study; ETDRS) and contrast sensitivity tests (Pelli-Robson) under different lighting conditions (luminosities from 0.14–55 cd/m2, mesopic to photopic) were performed at different distances. Results Visual acuity tests showed no difference for corrected distance visual acuity data of bi- and trifocal lens prototypes (P = 0.851), but better results for the trifocal than for the bifocal lenses at distance corrected intermediate (P = 0.021) and distance corrected near visual acuity (P = 0.044). Contrast sensitivity showed no differences between bifocal and trifocal lenses at the distant (P = 0.984) and at the near position (P = 0.925), but better results for the trifocal lens at the intermediate position (P = 0.043). Visual acuity and contrast sensitivity showed a strong dependence on luminosity (P < 0.001). Conclusions At all investigated distances and all lighting conditions, the trifocal lens prototype often performed better, but never worse than the bifocal lens prototype. Translational Relevance The vision simulator can fill the gap between preclinical lens development and implantation studies by providing information of the perceived vision quality after cataract surgery without implantation. This can reduce implantation risks and promotes the development of new lens concepts due to the cost effective test procedure. PMID:27777828

  6. Early clinical outcome with a new monofocal microincision intraocular lens.

    Science.gov (United States)

    Toygar, Baha; Yabas Kiziloglu, Ozge; Toygar, Okan; Hacimustafaoglu, Ali Murat

    2016-10-01

    The purpose of this study was to evaluate the early visual and refractive outcomes of a new aspheric monofocal microincision intraocular lens (IOL). This retrospective case series included eyes of patients who underwent implantation of a microincision IOL following 1.8 mm manual coaxial microincision cataract surgery and who attended regular postoperative follow-up visits on the first week and first, third, and sixth months. The postoperative uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), refraction and predictability, intraoperative and postoperative complications, posterior capsule opacification (PCO), IOL centration, and surgically induced astigmatism (SIA) were evaluated. Sixty-three eyes of 38 patients ranging in age from 51 to 86 were included in the study. The mean preoperative BCVA was 0.52 ± 0.42 logMAR. At the postoperative sixth month, the mean postoperative UCVA and BCVA were 0.12 ± 0.11 and 0.01 ± 0.03 logMAR, respectively. The mean postoperative spherical equivalent refraction (SER) was -0.30 ± 0.49 D. The SER was within ± 1.00 D of the attempted correction in 95.2 % of the eyes. The mean SIA measured with vector analysis was 0.45 ± 0.28 D. Mild PCO was observed in 9 eyes (14.7 %) with none requiring Nd:Yag laser capsulotomy. On centration analysis, the IOL was found to be 0.26 mm on average to the supero-nasal position. The aspheric microincision IOL was safely implanted and provided satisfactory visual and refractive outcomes in the early postoperative period.

  7. Retreatments after multifocal intraocular lens implantation: an analysis

    Science.gov (United States)

    Gundersen, Kjell Gunnar; Makari, Sarah; Ostenstad, Steffen; Potvin, Rick

    2016-01-01

    Purpose To determine the incidence and etiology of required retreatment after multifocal intraocular lens (IOL) implantation and to evaluate the methods and clinical outcomes of retreatment. Patients and methods A retrospective chart review of 416 eyes of 209 patients from one site that underwent uncomplicated cataract surgery with multifocal IOL implantation. Biometry, the IOL, and refractive data were recorded after the original implantation, with the same data recorded after retreatment. Comments related to vision were obtained both before and after retreatment for retreated patients. Results The multifocal retreatment rate was 10.8% (45/416 eyes). The eyes that required retreatment had significantly higher residual refractive astigmatism compared with those who did not require retreatment (1.21±0.51 D vs 0.51±0.39 D, P<0.01). The retreatment rate for the two most commonly implanted primary IOLs, blended bifocal (10.5%, 16/152) and bilateral trifocal (6.9%, 14/202) IOLs, was not statistically significantly different (P=0.12). In those requiring retreatment, refractive-related complaints were most common. Retreatment with refractive corneal surgery, in 11% of the eyes, and piggyback IOLs, in 89% of the eyes, was similarly successful, improving patient complaints 78% of the time. Conclusion Complaints related to ametropia were the main reasons for retreatment. Residual astigmatism appears to be an important determinant of retreatment rate after multifocal IOL implantation. Retreatment can improve symptoms for a high percentage of patients; a piggyback IOL is a viable retreatment option. PMID:27041983

  8. Intraocular lens exchange for high myopia in pseudophakic children.

    Science.gov (United States)

    Kraus, C L; Trivedi, R H; Wilson, M E

    2016-09-01

    PurposeThe purpose of this study was to examine the preoperative factors and postoperative outcomes following intraocular lens (IOL) exchange for high myopia in pseudophakic children.MethodsThe medical records of all patients undergoing IOL exchange for high myopia were retrospectively reviewed.ResultsA total of 15 eyes were identified that had undergone an IOL exchange for myopic shift. Average age of cataract extraction (CE) was 5.4 months. In all, 10/15 had a unilateral cataract. IOL exchange usually occurred at an average of 6 years following cataract surgery. The average spherical equivalent (SE) of the refractive error at that time was -9.6 D. Following IOL exchange, SE was -1.3 D. A two-line reduction in best-corrected visual acuity was observed in 1/13 of our patients for whom pre- and post-exchange data were available. The average axial length (AL) of the eye undergoing the IOL exchange was 24.0 mm, average AL in the non-operative eye was 22.1 mm. On average, the operative eyes grew 4.4 mm and the non-operative eyes 3.02 mm. No adverse events were seen in the operative eyes.ConclusionYounger age at the time of CE creates a greater likelihood of AL elongation and predisposes a child to myopic shift. IOL exchange should be considered an option to reduce anisometropia and associated aniseikonia to improve visual outcomes. Successful visual rehabilitation and predictable post-exchange refractions were seen with our patients.

  9. Long-term heavy silicone oil intraocular tamponade.

    Science.gov (United States)

    Dooley, Ian J; Duignan, Emma S; Kilmartin, Dara J

    2016-02-01

    Heavy silicone oil tamponade is intended to be temporary, but may occasionally be indefinite in patients who refuse, or are deemed unsuitable for, further surgery. The aim of this study is to compare the outcomes of patients with temporary versus indefinite heavy silicone oil intraocular tamponade. This retrospective, comparative case series identified 75 patients who underwent heavy silicone oil instillation (Oxane HD) over a 6 year period (2006-2012) in one institution. Thirty-nine patients had temporary heavy oil tamponade and 36 patients had indefinite tamponade. The majority (68 %) of patients had a history of previous vitreoretinal surgery prior to oil instillation and 66.7 % had pre-existing proliferative vitreoretinopathy (PVR). The mean final logMAR best corrected visual acuity (BCVA) was significantly better in the temporary tamponade group (1.34 ± 0.66) than the indefinite tamponade group 1.82 ± 0.64 (p = 0.003). Ambulatory BCVA (≥ 4/200) was retained in 76.3 % of temporary tamponade patients versus 54.3 % of indefinite tamponade patients (p = 0.093). Successful retinal reattachment was significantly more likely in temporary tamponade patients (92.3 %) than indefinite tamponade patients (75 %; p = 0.04). Complications in the patients with indefinite heavy silicone oil tamponade included redetachment (38.9 %), corneal pathology (13.8 %), secondary glaucoma (11.1 %) and anterior segment emulsification (8.3 %).While temporary tamponade patients had better outcomes than those with indefinite tamponade, the majority of indefinite tamponade patients still retained ambulatory vision in the affected eye. Indefinite heavy silicone oil tamponade remains a viable option for those who cannot undergo removal of oil surgery.

  10. Effects of fasting on intraocular pressure in a black population

    Directory of Open Access Journals (Sweden)

    Mustapha B Hassan

    2014-01-01

    Full Text Available Introduction: There is a dearth of literature available on the effects of fasting on Intraocular pressure (IOP among all races and worldwide. Objectives : To determine the effects of fasting on IOP in a black African population. Materials and Methods: A population-based survey utilizing multistage random sampling techniques was carried out among healthy adult Muslims who were examined before and during Ramadan fast in Osogbo, Nigeria. Demographics were obtained, visual acuities, clinical examination of both eyes, and IOPs were done. Weights and waist circumference were measured. Data were analyzed using Statistical Package for Social Sciences ( SPSS Version 16. Analysis generated frequencies and cross tabulations, whereas statistical significant values were derived using paired sample t-test and P < 0.05. Results: A total of 60 subjects with 120 eyes were examined. Mean age was 42.3 years standard deviation (SD 16.7, and the male to female ratio was 3:2. Majority were professionals (33.3%. Only 18.3% had less than secondary school education. Over 90% had normal vision (6/5-6/18. Before and during fasting, the mean weights were 65.92 kg SD 12.98 and 65.29 kg SD 12.41 with a reduction of 0.63 kg SD 3.82 (P = 0.214, 95% confidence interval (CI: 0.372-1.626; and the mean waist circumference was 87.20 cm SD 12.39 and 81.78 cm SD 11.65 (P = 0.000, 95% CI 4.128-6.720, respectively. Mean IOPs were 15.98 mmHg SD 3.11 and 14.08 mmHg SD 2.71 before and during fasting, respectively (P = 0.000, 95% CI 0.98558-2.82798. Conclusions: The study shows that fasting significantly reduced IOP in an ocularly healthy black African population.

  11. Intraocular caspofungin: in vitro safety profile for human ocular cells.

    Science.gov (United States)

    Kernt, M; Kampik, A

    2011-07-01

    Endogenous Candida endophthalmitis is sight-threatening, difficult to treat and sometimes leads to loss of the eye. Only a few therapeutic agents are available for its treatment. Caspofungin is the first of a new class of antifungal drugs (echinocandins) with a high activity against Candida species, the most common pathogens found in endogenous endophthalmitis. This study investigates the safety profile of caspofungin for intraocular application in a cell-culture model. Endothelial toxicity of caspofungin was evaluated in cultured human corneas. Possible toxic effects of caspofungin (5-300 μg ml(-1)) in corneal endothelial cells (CEC), primary human trabecular meshwork cells (TMC) and primary human retinal pigment epithelium (RPE) cells were evaluated after 24 h and under conditions of inflammatory stress by treatment with tumour necrosis factor-alpha (TNF-α), lipopolysaccharides (LPS) or interleukin-6 (IL-6) and hydrogen peroxide (H(2)O(2)). Toxicity was evaluated by tetrazolium dye-reduction assay; cell viability was quantified by a microscopic live-dead assay. No corneal endothelial toxicity could be detected after 30 days of treatment with 75 μg ml(-1) of caspofungin. Concentrations up to 75 μg ml(-1) had no influence on CEC, TMC or RPE cell proliferation, or on cell viability when administered for 24 h. Exposure to H(2)O(2) did not increase cellular toxicity of caspofungin at concentrations of 5-50 μg ml(-1). After preincubation with TNF-α, LPS or IL-6 for 24 h followed by treatment with caspofungin for 24 h, no significant decrease in cell proliferation or viability was observed. This study showed no significant toxicity for caspofungin on CEC, TMC or RPE cells, or human corneal endothelium when administered in therapeutic concentrations up to 50 μg ml(-1).

  12. Intraocular lens implantation for the treatment of astigmatism%人工晶状体植入术矫正散光

    Institute of Scientific and Technical Information of China (English)

    施俊廷; 徐雯

    2013-01-01

    Refractive intraocular lens surgery can be used for the treatment of moderate and high regular astigmatism.Refractive intraocular lens surgery includes aphakic intraocular lens surgery and phakic intraocular lens surgery.In phakic intraocular lens surgery two types of intraocular lenses are used:iris-claw intraocular lens and posterior chamber intraocular lens.The purpose of this article is to review current knowledge of surgical treatments of astigmatism with a particular focus on toric implantable collamer lenses.%人工晶状体(IOL)植入术能矫正中、高度规则散光.矫正散光的IOL植入术可分为无晶状体眼及有晶状体眼的环曲面IOL植入两类,其中有晶状体眼的环曲面IOL又可分为虹膜夹持型及后房型.本文旨在介绍IOL矫正散光的手术治疗方法,并着重介绍有晶状体眼植入后房型IOL矫正屈光不正合并散光的治疗技术.

  13. Artificial Neural Networks

    OpenAIRE

    Chung-Ming Kuan

    2006-01-01

    Artificial neural networks (ANNs) constitute a class of flexible nonlinear models designed to mimic biological neural systems. In this entry, we introduce ANN using familiar econometric terminology and provide an overview of ANN modeling approach and its implementation methods.

  14. Introduction to artificial intelligence

    Science.gov (United States)

    Cheeseman, P.; Gevarter, W.

    1986-01-01

    This paper presents an introductory view of Artificial Intelligence (AI). In addition to defining AI, it discusses the foundations on which it rests, research in the field, and current and potential applications.

  15. [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

    Science.gov (United States)

    Kohnen, T; Baumeister, M; Cichocki, M

    2005-10-01

    In this overview, the current status of intraocular lens surgery to correct refractive error is reviewed. The interventions are divided into additive surgery with intraocular lens implantation without extraction of the crystalline lens (phakic intraocular lens, PIOL) or the removal of the crystalline lens with implantation of an IOL (refractive lens exchange, RLE). Phakic IOLs are constructed as angle-supported or iris-fixated anterior chamber lenses and posterior chamber lenses that are fixated in the ciliary sulcus. The implantation of phakic IOLs has been demonstrated to be an effective, safe, predictable and stable procedure to correct higher refractive errors. Complications are rare and differ for the three types of PIOL; for anterior chamber lenses these are mainly pupil ovalization and endothelial cell loss.

  16. Influence of untreated chronic plastic iridocyclitis on intraocular pressure in leprosy patients.

    Science.gov (United States)

    Karaçorlu, M A; Cakiner, T; Saylan, T

    1991-02-01

    The intraocular pressures of a total of 286 eyes of patients with lepromatous and borderline lepromatous leprosy who never had regular ophthalmological care or local eye treatment were measured. The patients were categorised according to the type of leprosy they had, and the eyes were categorised as without or with chronic plastic iridocyclitis. In patients with lepromatous and borderline lepromatous types of leprosy the intraocular pressure was significantly lower in eyes with chronic plastic iridocylitis 10.1 (3.6) mmHg than in both unaffected eyes 11.0 (3.2) mmHg and control eyes 13.5 (2.5) mmHg. It has been shown that chronic plastic iridocyclitis which remains untreated for years results in a lower intraocular pressure than normal.

  17. Laser-triggered intraocular implant to induce photodynamic therapy for posterior capsule opacification prevention.

    Science.gov (United States)

    Zhang, Zhaoguo; Huang, Wenyong; Lei, Ming; He, Yuanfeng; Yan, Mina; Zhang, Xuefei; Zhao, Chunshun

    2016-02-10

    Posterior capsule opacification (PCO) is one of the main reasons for loss of vision again after cataract surgery. In this study, intraocular lenses were modified with indocyanine green (ICG) and sealed up with PLGA to form long-term intraocular implants (ICG-IOL). When triggered by laser, ICG-IOL would induce photodynamic therapy (PDT). In-vitro cell viability assay and scratch wound healing assay demonstrated that ICG-IOL could effectively inhibit HLEpiC proliferation and migration without causing damage to the cells far away from it. Laser attenuation test indicated that ICG-IOL could be applied in vivo. In-vivo pharmacodynamics and safety study showed that ICG-IOL could significantly prevent the occurrence of PCO and was safe for intraocular normal tissue. All these results suggested that ICG-IOL would be a very promising candidate for PCO prevention.

  18. Modified Scleral Flap Incision to Reduce Corneal Astigmatisn after Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    YizhiLiu; ShaozhenLi

    1995-01-01

    Purpose:To investigate a simple method during extracapsular cataract extraction with posteior chamber intraocular lens implantation in order to reduce surgically induced corneal astig-matism.Methods:A modified scleral flap incision was used in the extracapsular cataract extraction with intraocular lens implantation and the postoperative changes in conreal astigmatism was observed.Results:The peak value of postoperative corneal astigmatism was3.60D,and the corneal astigmatism regression was 2.11D,surgically induced astigmatism was less significant in modified scleral flap incision group than that in convention-al limbal incison group(P<0.05).Conclusions:The modified scleral flap inciston is an ideal incision for cataract ex-traction with intraocular lens implantation when phacoemulsifier is not avaliable.Eye Science1995;11:136-139.

  19. Principles of artificial intelligence

    CERN Document Server

    Nilsson, Nils J

    1980-01-01

    A classic introduction to artificial intelligence intended to bridge the gap between theory and practice, Principles of Artificial Intelligence describes fundamental AI ideas that underlie applications such as natural language processing, automatic programming, robotics, machine vision, automatic theorem proving, and intelligent data retrieval. Rather than focusing on the subject matter of the applications, the book is organized around general computational concepts involving the kinds of data structures used, the types of operations performed on the data structures, and the properties of th

  20. Physics of Artificial Gravity

    Science.gov (United States)

    Bukley, Angie; Paloski, William; Clement, Gilles

    2006-01-01

    This chapter discusses potential technologies for achieving artificial gravity in a space vehicle. We begin with a series of definitions and a general description of the rotational dynamics behind the forces ultimately exerted on the human body during centrifugation, such as gravity level, gravity gradient, and Coriolis force. Human factors considerations and comfort limits associated with a rotating environment are then discussed. Finally, engineering options for designing space vehicles with artificial gravity are presented.

  1. Heidegger and artificial intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, G.

    1987-01-01

    The discipline of Artificial Intelligence, in its quest for machine intelligence, showed great promise as long as its areas of application were limited to problems of a scientific and situation neutral nature. The attempts to move beyond these problems to a full simulation of man's intelligence has faltered and slowed it progress, largely because of the inability of Artificial Intelligence to deal with human characteristic, such as feelings, goals, and desires. This dissertation takes the position that an impasse has resulted because Artificial Intelligence has never been properly defined as a science: its objects and methods have never been identified. The following study undertakes to provide such a definition, i.e., the required ground for Artificial Intelligence. The procedure and methods employed in this study are based on Heidegger's philosophy and techniques of analysis as developed in Being and Time. Results of this study show that both the discipline of Artificial Intelligence and the concerns of Heidegger in Being and Time have the same object; fundamental ontology. The application of Heidegger's conclusions concerning fundamental ontology unites the various aspects of Artificial Intelligence and provides the articulation which shows the parts of this discipline and how they are related.

  2. Undervisning af tosprogede elever

    DEFF Research Database (Denmark)

    Horst, Christian

    2003-01-01

    Artiklen fremdrager hovedresultaterne fra Virginia P. Collier's og Wayne P. Thomas's længdeundersøgelser af tosprogede elever i USA, som formentlig er de mest omfattende undersøgelser af undervisningen af tosprogede elever overhovedet. Resultaterne diskuteres i relation til udviklingen af en...

  3. Role of interferon-γ and cytotoxic T lymphocytes in intraocular tumor rejection.

    Science.gov (United States)

    Ligocki, Ann J; Brown, Joseph R; Niederkorn, Jerry Y

    2016-05-01

    The eye is normally an immunosuppressive environment. This condition is better known as immune privilege and protects the eye from immune-mediated inflammation of tissues that cannot regenerate. However, immune privilege creates a dilemma for the eye when intraocular neoplasms arise. In some cases, immune privilege is suspended, resulting in the immune rejection of intraocular tumors. This study employed a mouse model in which interferon-γ-dependent intraocular tumor rejection occurs. We tested the hypothesis that this rejection requires interferon-γ for the generation and functional capacity of cytotoxic T lymphocyte-mediated rejection of intraocular tumors. Tumors grew progressively in the eyes of interferon-γ knockout mice, even though the mice generated tumor-specific cytotoxic T lymphocyte responses in the periphery. However, interferon-γ knockout mice rejected tumors that were introduced into extraocular sites. Subcutaneous tumor immunization before intraocular challenge led to tumor rejection and preservation of the eye in wild-type mice. By contrast, tumors grew progressively in the eyes of interferon-γ knockout mice despite their ability to generate peripheral tumor-specific cytotoxic T lymphocytes as well as the capacity of CD8(+) T cells to enter the eye as shown by the presence of CD8 and perforin message and CD3(+)CD8(+) leukocytes within the tumor-bearing eye. We found that cytotoxic T lymphocytes generated in wild-type mice and adoptively transferred into interferon-γ knockout mice mediated the rejection of intraocular tumors in interferon-γ knockout hosts. The results indicate that interferon-γ is critical for the initial priming and differentiation of cytotoxic T lymphocytes residing in the periphery to produce the most effect antitumor function within the eye.

  4. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses

    Directory of Open Access Journals (Sweden)

    Wei Ching-Kuo

    2012-10-01

    Full Text Available Abstract Background The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients’ decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. Methods This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one’s own expense, overall patient satisfaction and postoperative visual clarity. Results The results showed that the patient’s gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Conclusions Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.

  5. Elevator and hydraulics; Elevator to yuatsu

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, I. [Hitachi, Ltd., Tokyo (Japan)

    1994-07-15

    A hydraulic type elevator is installed in relatively lower buildings as compared with a rope type elevator, but the ratio in the number of installation of the former elevator is increasing. This paper explains from its construction and features to especially various control systems for the riding comfort and safety. A direct push-up system with hydraulic jacks arranged beneath a car, and an indirect push-up system that has hydraulic jacks arranged on flank of a car and transmits the movement of a plunger via a rope are available. The latter system eliminates the need of large holes to embed hydraulic jacks. While the speed is controlled by controlling flow rates of high-pressure oil, the speed, position, acceleration and even time differential calculus of the acceleration must be controlled severely. The system uses two-step control for the through-speed and the landing speed. Different systems that have been realized may include compensation for temperatures in flow rate control valves, load pressures, and oil viscosity, from learning control to fuzzy control for psychological effects, or control of inverters in motors. 13 refs., 12 figs., 1 tab.

  6. Ophthalmic viscosurgical device backflow into cartridge during intraocular lens insertion using injectors

    Directory of Open Access Journals (Sweden)

    Matsuura K

    2014-01-01

    Full Text Available Kazuki Matsuura,1 Yoshitsugu Inoue2 1Nojima Hospital, 2Tottori University, Kurayoshi City, Tottori, Japan Background: The purpose of this study was to assess the risk of intraocular contamination caused by intraocular lens (IOL insertion with injectors by observing the dynamics of an ophthalmic viscosurgical device (OVD. Methods: Each type of injector was equipped with a colored OVD and IOL, and a 2 mm length from the tip of the cartridge was replaced with a colored OVD. The various combinations of IOLs and injectors used were: a three-piece shaped IOL, VA60BBR + TypeE1 (HOYA incision size 2.5 mm; group A, n=5; a single-piece IOL, 251+ iSert micro, preloaded (HOYA, incision size 2.2 mm; group G, n=5; and a single-piece IOL, SN6CWS preloaded (Alcon, incision size 2.7 mm; group C, n=5. Results: In group A, the intraocular OVD instantly flowed backward into the injector, whereas the colored OVD was pushed backward deep inside the cartridge without flowing into the eye. In group B, the backflow of the intraocular OVD into the injector was limited, resulting in the influx of a large amount of the colored OVD into the eye along with the IOL. In group C, as in group A, a large amount of the intraocular OVD flowed backward into the injector. Consequently, a small amount of the colored OVD flowed into the eye. Conclusion: The tip of the injector and OVD could be contaminated because the surgical field cannot be completely sterile, even after preoperative disinfection. Our experiments revealed that OVD backflow into the injector cavity occurs during IOL insertion, and this phenomenon may have minimized intraocular contamination. However, small-diameter cartridges along with plate-type haptics allow insufficient OVD backflow, resulting in intraocular influx of the contaminated OVD. Surgeons have to be notified that intraoperative bacterial contamination can occur even after IOL insertion using injectors. Keywords: intraocular lens insertion

  7. Symbolic algebra approach to the calculation of intraocular lens power following cataract surgery

    Science.gov (United States)

    Hjelmstad, David P.; Sayegh, Samir I.

    2013-03-01

    We present a symbolic approach based on matrix methods that allows for the analysis and computation of intraocular lens power following cataract surgery. We extend the basic matrix approach corresponding to paraxial optics to include astigmatism and other aberrations. The symbolic approach allows for a refined analysis of the potential sources of errors ("refractive surprises"). We demonstrate the computation of lens powers including toric lenses that correct for both defocus (myopia, hyperopia) and astigmatism. A specific implementation in Mathematica allows an elegant and powerful method for the design and analysis of these intraocular lenses.

  8. Comparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens

    Science.gov (United States)

    Gundersen, Kjell Gunnar; Potvin, Rick

    2016-01-01

    Purpose The aim of this study was to compare a new diffractive trifocal toric lens with an apodized diffractive bifocal toric lens in terms of refractive and visual acuity (VA) outcomes, including low-contrast VA (LCVA), as well as the patient’s visual function 3 months after implantation. Patients and methods This is a randomized prospective study involving bilateral implantation of a trifocal toric or a bifocal toric lens. At 3 months postoperatively, the subject’s vision was tested both uncorrected and with his/her best distance correction at: distance (4 m), intermediate (63 cm), and near (40 cm). Binocular defocus curves were measured with no correction and with the subject’s best distance correction in place. Quality of vision was measured using the National Eye Institute Visual Function Questionnaire. Results A total of 22 patients were enrolled (eleven in each group). There was no statistically significant difference in the absolute change in measured rotation between 1 month and 3 months postoperatively between the two intraocular lens (IOL) groups (P=0.98). At 3 months, the postoperative refraction and distance VA by eye were similar between groups. There was no statistically significant difference in the measured LCVA between groups (P=0.39). The defocus curve showed that at 67 cm, the trifocal toric lens had statistically significantly better VA when compared to the bifocal toric lens. There were no statistically significant differences by group for any of the National Eye Institute Visual Function Questionnaire scores (P>0.26 in all cases). Conclusion The trifocal toric IOL improved the intermediate vision without negatively impacting visual function and distance, near, or low-contrast VA when compared to a bifocal toric IOL. The toric component of the trifocal lens effectively reduced astigmatism and provided good rotational stability. PMID:27051269

  9. Sensitivity of the corneal-plane refractive compensation to change in power and axial position of an intraocular lens

    Directory of Open Access Journals (Sweden)

    W. F. Harris

    2009-12-01

    Full Text Available If an intraocular lens is displaced or if its power is changed what are the consequences for the refractive compensation of the eye?  Gaussian optics is used to obtain explicit formulae for the sensitivityof the corneal-plane refractive compensation (also called the refraction, refractive state, etc to change in power and axial displacement of a thin intraocular lens implanted in a simple eye.  In particular, for a pseudophakic Gullstrand simplified eye with intraocular lens placed 5 mm behind the cornea the sensitivity to errors in the power of the intraocular lens is about  71 . 0 − 71 for an intraocular lens of power   for an intraocular lens of power 20 D, that is, the refractive compensation decreases by about 0.71 dioptres per dioptre increase in the power of the intraocular lens.  More generally the sensitivity is approximately  ( m   0037 . 0 63 . 0 F − − 0.63 ( 003 . 0 63 . 0 − − (0.0037mF where FI is the power of the intraocular lens.  Also for Gullstrand’s simplified eye the sensitivity of refractive compensation to axial displacement of the intraocular lens is approximately linear in FI about  (64D FI, in fact.  That is, for each dioptre of the power of the intraocular lens the refractive compensation increases by about 0.064 dioptres per millimetre of axial displacement towards the retina. 

  10. Pregnenolone sulfate decreases intraocular pressure and changes expression of sigma receptor in a model of chronic ocular hypertension.

    Science.gov (United States)

    Sun, Xian; Cheng, Fang; Meng, Bo; Yang, Binbin; Song, Wulian; Yuan, Huiping

    2012-06-01

    Sigma receptors are Ca(2+)-sensitive, ligand-operated receptor chaperones at the mitochondrion-associated endoplasmic reticulum membrane. This study describes the effect of the sigma receptor 1 agonist pregnenolone sulfate on intraocular pressure (IOP) and sigma receptor 1 expression in rat retinas after chronic ocular hypertension. Chronic ocular hypertension was induced by occlusion of episcleral veins. Retinal histological sections were obtained to determine inner plexiform layer thickness and the number of cell bodies in the ganglion cell layer. Sigma receptor expression in rat retinas was analyzed by RT-PCR and Western blotting. Cauterization caused IOP to increase >73%, and the pressure was maintained for 2 months. A time-dependent loss of ganglion cells and retinal thickness occurred at elevated IOP. High IOP decreased sigma receptor 1 expression during the first week, but expression was increased at 8 weeks. Injected pregnenolone significantly decreased IOP, prevented ganglion cell loss, protected inner plexiform layer thickness, and increased sigma receptor 1 expression in episcleral vein-cauterized rats. Sigma receptors appear to be neuroprotective and potential targets for glaucoma therapeutics.

  11. Genome-wide analysis of multi-ancestry cohorts identifies new loci influencing intraocular pressure and susceptibility to glaucoma.

    Science.gov (United States)

    Hysi, Pirro G; Cheng, Ching-Yu; Springelkamp, Henriët; Macgregor, Stuart; Bailey, Jessica N Cooke; Wojciechowski, Robert; Vitart, Veronique; Nag, Abhishek; Hewitt, Alex W; Höhn, René; Venturini, Cristina; Mirshahi, Alireza; Ramdas, Wishal D; Thorleifsson, Gudmar; Vithana, Eranga; Khor, Chiea-Chuen; Stefansson, Arni B; Liao, Jiemin; Haines, Jonathan L; Amin, Najaf; Wang, Ya Xing; Wild, Philipp S; Ozel, Ayse B; Li, Jun Z; Fleck, Brian W; Zeller, Tanja; Staffieri, Sandra E; Teo, Yik-Ying; Cuellar-Partida, Gabriel; Luo, Xiaoyan; Allingham, R Rand; Richards, Julia E; Senft, Andrea; Karssen, Lennart C; Zheng, Yingfeng; Bellenguez, Céline; Xu, Liang; Iglesias, Adriana I; Wilson, James F; Kang, Jae H; van Leeuwen, Elisabeth M; Jonsson, Vesteinn; Thorsteinsdottir, Unnur; Despriet, Dominiek D G; Ennis, Sarah; Moroi, Sayoko E; Martin, Nicholas G; Jansonius, Nomdo M; Yazar, Seyhan; Tai, E-Shyong; Amouyel, Philippe; Kirwan, James; van Koolwijk, Leonieke M E; Hauser, Michael A; Jonasson, Fridbert; Leo, Paul; Loomis, Stephanie J; Fogarty, Rhys; Rivadeneira, Fernando; Kearns, Lisa; Lackner, Karl J; de Jong, Paulus T V M; Simpson, Claire L; Pennell, Craig E; Oostra, Ben A; Uitterlinden, André G; Saw, Seang-Mei; Lotery, Andrew J; Bailey-Wilson, Joan E; Hofman, Albert; Vingerling, Johannes R; Maubaret, Cécilia; Pfeiffer, Norbert; Wolfs, Roger C W; Lemij, Hans G; Young, Terri L; Pasquale, Louis R; Delcourt, Cécile; Spector, Timothy D; Klaver, Caroline C W; Small, Kerrin S; Burdon, Kathryn P; Stefansson, Kari; Wong, Tien-Yin; Viswanathan, Ananth; Mackey, David A; Craig, Jamie E; Wiggs, Janey L; van Duijn, Cornelia M; Hammond, Christopher J; Aung, Tin

    2014-10-01

    Elevated intraocular pressure (IOP) is an important risk factor in developing glaucoma, and variability in IOP might herald glaucomatous development or progression. We report the results of a genome-wide association study meta-analysis of 18 population cohorts from the International Glaucoma Genetics Consortium (IGGC), comprising 35,296 multi-ancestry participants for IOP. We confirm genetic association of known loci for IOP and primary open-angle glaucoma (POAG) and identify four new IOP-associated loci located on chromosome 3q25.31 within the FNDC3B gene (P = 4.19 × 10(-8) for rs6445055), two on chromosome 9 (P = 2.80 × 10(-11) for rs2472493 near ABCA1 and P = 6.39 × 10(-11) for rs8176693 within ABO) and one on chromosome 11p11.2 (best P = 1.04 × 10(-11) for rs747782). Separate meta-analyses of 4 independent POAG cohorts, totaling 4,284 cases and 95,560 controls, showed that 3 of these loci for IOP were also associated with POAG.

  12. Comparison of two optical biometers in intraocular lens power calculation

    Directory of Open Access Journals (Sweden)

    Sheng Hui

    2014-01-01

    Full Text Available Aims: To compare the consistency and accuracy in ocular biometric measurements and intraocular lens (IOL power calculations using the new optical low-coherence reflectometry and partial coherence interferometry. Subjects and Methods: The clinical data of 122 eyes of 72 cataract patients were analyzed retrospectively. All patients were measured with a new optical low-coherence reflectometry system, using the LENSTAR LS 900 (Haag Streit AG/ALLEGRO BioGraph biometer (Wavelight., AG, and partial coherence interferometry (IOLMaster V.5.4 [Carl Zeiss., Meditec, AG] before phacoemulsification and IOL implantation. Repeated measurements, as recommended by the manufacturers, were performed by the same examiner with both devices. Using the parameters of axial length (AL, corneal refractive power (K1 and K2, and anterior chamber depth (ACD, power calculations for AcrySof SA60AT IOL were compared between the two devices using five formulas. The target was emmetropia. Statistical analysis was performed using Statistical Package for the Social Sciences software (SPSS 13.0 with t-test as well as linear regression. A P value < 0.05 was considered to be statistically significant. Results: The mean age of 72 cataract patients was 64.6 years ± 13.4 [standard deviation]. Of the biometry parameters, K1, K2 and [K1 + K2]/2 values were significantly different between the two devices (mean difference, K1: −0.05 ± 0.21 D; K2: −0.12 ± 0.20 D; [K1 + K2]/2: −0.08 ± 0.14 D. P <0.05. There was no statistically significant difference in AL and ACD between the two devices. The correlations of AL, K1, K2, and ACD between the two devices were high. The mean differences in IOL power calculations using the five formulas were not statistically significant between the two devices. Conclusions: New optical low-coherence reflectometry provides measurements that correlate well to those of partial coherence interferometry, thus it is a precise device that can be used for the

  13. Toric intraocular lens orientation and residual refractive astigmatism: an analysis

    Directory of Open Access Journals (Sweden)

    Potvin R

    2016-09-01

    Full Text Available Rick Potvin,1 Brent A Kramer,2 David R Hardten,3 John P Berdahl4 1Science in Vision, Akron, NY, 2University of Iowa Carver College of Medicine, Iowa City, IA, 3Minnesota Eye Consultants, Minnetonka, MN, 4Vance Thompson Vision, Sioux Falls, SD, USA Purpose: To analyze intraocular lens (IOL orientation data from an online toric back-calculator (astigmatismfix.com for determining if differences were apparent by lens type.Methods: A retrospective review of astigmatismfix.com toric back-calculations that included IOL identification and intended orientation axis.Results: Of 12,812 total validated calculation records, 8,229 included intended orientation and lens identification data. Of the latter, 5,674 calculations (69% involved lenses oriented 5° or more from their intended position. Using estimated toric lens usage data, the percentage of lenses with orientation ≥5° from intended was 0.89% overall, but the percentage varied significantly between specific toric lens brands (P<0.05. The percentage of back-calculations related to lenses that were not oriented as intended was also statistically significantly different by lens brand (P<0.05. When IOLs were misoriented, they were significantly more likely to be misoriented in a counterclockwise direction (P<0.05. This was found to be due to a bias toward counterclockwise orientation observed with one specific brand, a bias that was not observed with the other three brands analyzed here.Conclusion: The percentage of eyes with lens orientation ≥5° from intended in the Toric Results Analyzer data set was <1% of toric IOLs in general, with the relative percentage of Tecnis® Toric IOLs significantly higher than AcrySof® Toric IOLs. Both of these had higher rates than the Staar® Toric and Trulign® Toric lenses, with the availability of higher Tecnis and AcrySof cylinder powers a likely contributing factor. The AcrySof Toric IOL appears to be less likely than the Tecnis Toric IOL to cause residual

  14. The impact of intraocular pressure on elastic wave velocity estimates in the crystalline lens

    Science.gov (United States)

    Park, Suhyun; Yoon, Heechul; Larin, Kirill V.; Emelianov, Stanislav Y.; Aglyamov, Salavat R.

    2017-02-01

    Intraocular pressure (IOP) is believed to influence the mechanical properties of ocular tissues including cornea and sclera. The elastic properties of the crystalline lens have been mainly investigated with regard to presbyopia, the age-related loss of accommodation power of the eye. However, the relationship between the elastic properties of the lens and IOP remains to be established. The objective of this study is to measure the elastic wave velocity, which represents the mechanical properties of tissue, in the crystalline lens ex vivo in response to changes in IOP. The elastic wave velocities in the cornea and lens from seven enucleated bovine globe samples were estimated using ultrasound shear wave elasticity imaging. To generate and then image the elastic wave propagation, an ultrasound imaging system was used to transmit a 600 µs pushing pulse at 4.5 MHz center frequency and to acquire ultrasound tracking frames at 6 kHz frame rate. The pushing beams were separately applied to the cornea and lens. IOP in the eyeballs was varied from 5 to 50 mmHg. The results indicate that while the elastic wave velocity in the cornea increased from 0.96  ±  0.30 m s-1 to 6.27  ±  0.75 m s-1 as IOP was elevated from 5 to 50 mmHg, there were insignificant changes in the elastic wave velocity in the crystalline lens with the minimum and the maximum speeds of 1.44  ±  0.27 m s-1 and 2.03  ±  0.46 m s-1, respectively. This study shows that ultrasound shear wave elasticity imaging can be used to assess the biomechanical properties of the crystalline lens noninvasively. Also, it was observed that the dependency of the crystalline lens stiffness on the IOP was significantly lower in comparison with that of cornea.

  15. Intraocular and systemic levels of vascular endothelial growth factor in advanced cases of retinopathy of prematurity

    Directory of Open Access Journals (Sweden)

    Raul Velez-Montoya

    2010-08-01

    Full Text Available Raul Velez-Montoya1, Carmen Clapp2, Jose Carlos Rivera2, Gerardo Garcia-Aguirre1, Virgilio Morales-Cantón1, Jans Fromow-Guerra1, Jose Luis Guerrero-Naranjo1, Hugo Quiroz-Mercado31Retina Department Asociación para Evitar la Ceguera en México IAP, México City, México; 2Department of Cellular and Molecular Neurobiology, Universidad Nacional Autónoma de México, Querétaro, México; 3Department of Ophthalmology, Denver Health Medical Center, University of Colorado School of Medicine, Colorado, USAPurpose: To measure vitreous, aqueous, subretinal fluid and plasma levels of vascular ­endothelial growth factor in late stages of retinopathy of prematurity.Methods: Interventional study. We enrolled patients with clinical diagnoses of bilateral stage V retinopathy of prematurity, confirmed by b-scan ultrasound and programmed for vitrectomy. During surgery we took samples from blood, aqueous, vitreous, and subretinal fluids. The vascular endothelial growth factor concentration in each sample was measured by ELISA reaction. A control sample of aqueous, vitreous and blood was taken from patients with congenital cataract programmed for phacoemulsification. For statistical analysis, a Mann–Whitney and a Wilcoxon W test was done with a significant P value of 0.05.Results: We took samples of 16 consecutive patients who met the inclusion criteria. The vascular endothelial growth factor levels in the study group were: aqueous, 76.81 ± 61.89 pg/mL; vitreous, 118.53 ± 65.87 pg/mL; subretinal fluid, 1636.58 ± 356.47 pg/mL; and plasma, 74.64 ± 43.94 pg/mL. There was a statistical difference between the study and the control group (P < 0.001 in the aqueous and vitreous samples.Conclusion: Stage 5 retinopathy of prematurity has elevated intraocular levels of vascular endothelial growth factor, which remains high despite severe retinal lesion. There was no ­statistical difference in plasma levels of the molecule between the control and study group

  16. Visual quality of multifocal, accommodative and monofocal intraocular lens: a comparative study of 139 eyes%多焦点、可调节和单焦点人工晶状体临床视觉质量的观察

    Institute of Scientific and Technical Information of China (English)

    郑登易; 叶剑; 谭薇

    2012-01-01

    concurrent control trial was carried out in 95 patients (139 eyes) with age-related cataract who receiving phacoemulsification and implantation of artificial intraocular lens in our department during September 2010 to April 2011. Forty-three eyes of 30 patients underwent phacoemulsification and implantation of ZMA00, and another 33 age- and sex-matched patients (49 eyes) and 32 patients (47 eyes) had the same surgery but implantated with FLEX and AKROS respectively. All patients were assessed for visual acuity, accommodation amplitude and contrast sensitivity visual acuity in 1 d, 1 and 3 months after operation. Results During the follow-up time, the patients in the ZMAOO and FLEX groups had better vision acuity than the AKROS group in uncorrected distance vision acuity ( UDVA) , but no significant difference was found (P > 0. 05). And the patients in the ZMA00 and FLEX groups had better corrected intermediate vision acuity (CIVA) than the AKROS group (P 0. 05). There were 86. 7% patients of the ZMA00 group, 63.6% of the FLEX group, and 18. 8% of the AKROS group achieving total spectacle independence. Conclusion Three kinds of artificial lens can get better distance vision, but multifocal and accommodative intraocular lens possesses far better, and the higher rate of spectacle independence. Aspheric multifocal intraocular lens have no loss in contrast sensitivity, and take greater advantages than accommodating intraocular lensin near vision, and pseudo-conditioning capability.

  17. Artificial vision workbench.

    Science.gov (United States)

    Frenger, P

    1997-01-01

    Machine vision is an important component of medical systems engineering. Inexpensive miniature solid state cameras are now available. This paper describes how these devices can be used as artificial retinas, to take snapshots and moving pictures in monochrome or color. Used in pairs, they produce a stereoscopic field of vision and enable depth perception. Macular and peripheral vision can be simulated electronically. This paper also presents the author's design of an artificial orbit for this synthetic eye. The orbit supports the eye, protects it, and provides attachment points for the ocular motion control system. Convergence and image fusion can be produced, and saccades simulated, along with the other ocular motions. The use of lenses, filters, irises and focusing mechanisms are also discussed. Typical camera-computer interfaces are described, including the use of "frame grabbers" and analog-to-digital image conversion. Software programs for eye positioning, image manipulation, feature extraction and object recognition are discussed, including the application of artificial neural networks.

  18. Artificial intelligence in nanotechnology.

    Science.gov (United States)

    Sacha, G M; Varona, P

    2013-11-15

    During the last decade there has been increasing use of artificial intelligence tools in nanotechnology research. In this paper we review some of these efforts in the context of interpreting scanning probe microscopy, the study of biological nanosystems, the classification of material properties at the nanoscale, theoretical approaches and simulations in nanoscience, and generally in the design of nanodevices. Current trends and future perspectives in the development of nanocomputing hardware that can boost artificial-intelligence-based applications are also discussed. Convergence between artificial intelligence and nanotechnology can shape the path for many technological developments in the field of information sciences that will rely on new computer architectures and data representations, hybrid technologies that use biological entities and nanotechnological devices, bioengineering, neuroscience and a large variety of related disciplines.

  19. Artificial muscles on heat

    Science.gov (United States)

    McKay, Thomas G.; Shin, Dong Ki; Percy, Steven; Knight, Chris; McGarry, Scott; Anderson, Iain A.

    2014-03-01

    Many devices and processes produce low grade waste heat. Some of these include combustion engines, electrical circuits, biological processes and industrial processes. To harvest this heat energy thermoelectric devices, using the Seebeck effect, are commonly used. However, these devices have limitations in efficiency, and usable voltage. This paper investigates the viability of a Stirling engine coupled to an artificial muscle energy harvester to efficiently convert heat energy into electrical energy. The results present the testing of the prototype generator which produced 200 μW when operating at 75°C. Pathways for improved performance are discussed which include optimising the electronic control of the artificial muscle, adjusting the mechanical properties of the artificial muscle to work optimally with the remainder of the system, good sealing, and tuning the resonance of the displacer to minimise the power required to drive it.

  20. Artificial intelligence in nanotechnology

    Science.gov (United States)

    Sacha, G. M.; Varona, P.

    2013-11-01

    During the last decade there has been increasing use of artificial intelligence tools in nanotechnology research. In this paper we review some of these efforts in the context of interpreting scanning probe microscopy, the study of biological nanosystems, the classification of material properties at the nanoscale, theoretical approaches and simulations in nanoscience, and generally in the design of nanodevices. Current trends and future perspectives in the development of nanocomputing hardware that can boost artificial-intelligence-based applications are also discussed. Convergence between artificial intelligence and nanotechnology can shape the path for many technological developments in the field of information sciences that will rely on new computer architectures and data representations, hybrid technologies that use biological entities and nanotechnological devices, bioengineering, neuroscience and a large variety of related disciplines.

  1. Artificial organ engineering

    CERN Document Server

    Annesini, Maria Cristina; Piemonte, Vincenzo; Turchetti, Luca

    2017-01-01

    Artificial organs may be considered as small-scale process plants, in which heat, mass and momentum transfer operations and, possibly, chemical transformations are carried out. This book proposes a novel analysis of artificial organs based on the typical bottom-up approach used in process engineering. Starting from a description of the fundamental physico-chemical phenomena involved in the process, the whole system is rebuilt as an interconnected ensemble of elemental unit operations. Each artificial organ is presented with a short introduction provided by expert clinicians. Devices commonly used in clinical practice are reviewed and their performance is assessed and compared by using a mathematical model based approach. Whilst mathematical modelling is a fundamental tool for quantitative descriptions of clinical devices, models are kept simple to remain focused on the essential features of each process. Postgraduate students and researchers in the field of chemical and biomedical engineering will find that t...

  2. Endophthalmitis due to an intra-ocular linear foreign body in a cat

    Directory of Open Access Journals (Sweden)

    Esmeralda Delgado

    2015-05-01

    Full Text Available Case summary An unusual case of an intraocular linear foreign body that migrated from the oral cavity, causing a severe endophthalmitis, in a cat is described. A 2-year-old female domestic shorthair cat presented with signs of infection from the left eye that had begun 2 weeks previously. Despite having been prescribed oral and topical antibiotics, there was a progressive worsening of the clinical signs. On ophthalmic examination the cat presented with severe endophthalmitis, secondary glaucoma and exposure keratitis of the left eye. Radiography demonstrated the presence of an intraocular linear metallic foreign body compatible with a sewing needle. During enucleation, when the globe was extracted, the sewing needle stayed in the orbit. When the needle was pulled away, a piece of thread was also retrieved, which demonstrated that the linear foreign body had migrated retrogradely from the oral cavity to the orbit through the pterygopalatine fossa. Surgical recovery was uneventful. Relevance and novel information Intraocular foreign bodies may present in a variety of ways, which may hinder their clinical detection. The management and prognosis depend on the composition and location of the foreign body, as well as the possible presence of secondary infection. To the author’s knowledge, this is the first time that a case of severe endophthalmitis following retrograde intraocular migration of a linear foreign body from the oral cavity to the orbit through the pterygopalatine fossa in a cat has been reported.

  3. Intraocular and extraocular hemorrhage associated with ligature release of non-valved glaucoma drainage implant

    Directory of Open Access Journals (Sweden)

    Michelle Go

    2017-04-01

    Conclusions: and importance: This is the first report of a rare occurrence of intraocular and extraocular hemorrhage associated following spontaneous release of ligature of a non-valved glaucoma drainage implant. The presumed mechanism was sudden shallowing of the anterior chamber resulting in the tube irritating uveal vasculature. We do not have an explanation for the extraocular blood.

  4. CORRECTION OF HIGH MYOPIA WITH THE WORST MYOPIA CLAW INTRAOCULAR-LENS

    NARCIS (Netherlands)

    LANDESZ, M; WORST, JGF; SIERTSEMA, JV; VANRIJ, G

    1995-01-01

    BACKGROUND: Phakic anterior chamber lenses is one of the modalities used to correct high myopia, We report the initial results of our prospective study on the Worst myopia claw intraocular lens (IOL) that is fixated to the anterior iris, METHODS: We studied 35 eyes in 18 patients with a preoperative

  5. Bilateral transient pupil closure after iris supported intraocular lens implantation in a case with Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Necip Kara

    2012-01-01

    Full Text Available A 16-year-old woman presented with Marfan syndrome and bilateral ectopia lentis. The surgical treatment including removal of the crystalline lens and implantation of an iris-supported intraocular lens in both eyes at a week interval. Postoperatively, the biomicroscopic examination showed total pupil closure bilaterally. After the topical tropicamide treatment, the pupil returned to normal shape.

  6. Implantation of Artisan toric phakic intraocular lens following Intacs in a patient with keratoconus.

    Science.gov (United States)

    Kamburoğlu, Günhal; Ertan, Aylin; Bahadir, Mehmet

    2007-03-01

    We report a 24-year-old man with bilateral keratoconus in whom Intacs (Addition Technology, Inc.) were implanted in both eyes. The procedure was followed by Artisan toric phakic intraocular lens (Ophtec) implantation to correct the residual myopic and astigmatic refractive error.

  7. An Intraocular Camera for Retinal Prostheses: Restoring Sight to the Blind

    Science.gov (United States)

    Stiles, Noelle R. B.; McIntosh, Benjamin P.; Nasiatka, Patrick J.; Hauer, Michelle C.; Weiland, James D.; Humayun, Mark S.; Tanguay, Armand R., Jr.

    Implantation of an intraocular retinal prosthesis represents one possible approach to the restoration of sight in those with minimal light perception due to photoreceptor degenerating diseases such as retinitis pigmentosa and age-related macular degeneration. In such an intraocular retinal prosthesis, a microstimulator array attached to the retina is used to electrically stimulate still-viable retinal ganglion cells that transmit retinotopic image information to the visual cortex by means of the optic nerve, thereby creating an image percept. We describe herein an intraocular camera that is designed to be implanted in the crystalline lens sac and connected to the microstimulator array. Replacement of an extraocular (head-mounted) camera with the intraocular camera restores the natural coupling of head and eye motion associated with foveation, thereby enhancing visual acquisition, navigation, and mobility tasks. This research is in no small part inspired by the unique scientific style and research methodologies that many of us have learned from Prof. Richard K. Chang of Yale University, and is included herein as an example of the extent and breadth of his impact and legacy.

  8. Uveitis in Thailand : emphasis on clinical patterns and novel developments in diagnostics using intraocular fluid analysis

    NARCIS (Netherlands)

    Pathanapitoon, K.

    2010-01-01

    In this thesis, we report on the so far unknown causes of uveitis in Thailand and describe their clinical manifestations. We found out that intraocular infections were the second most common cause of blindness and low vision in a tertiary center in northern Thailand. These infections predominantly c

  9. Iris-fixated anterior chamber phakic intraocular lens for myopia moves posteriorly with mydriasis.

    NARCIS (Netherlands)

    Cruysberg, L.P.J.; Doors, M.; Berendschot, T.T.; Brabander, J. De; Webers, C.A.; Nuijts, R.M.

    2009-01-01

    PURPOSE: To elucidate the physiological characteristics of eyes implanted with iris-fixated anterior chamber phakic intraocular lenses (pIOLs), which are increasingly being used for the correction of higher myopic and hyperopic refractive errors. METHODS: In a case series of 20 patients (39 eyes), t

  10. Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Ugur Unsal

    2016-01-01

    Full Text Available Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed. Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later. Results. The corrected and uncorrected distance visual acuity were the same between both groups (p=0.50 and p=0.509, resp.. The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p=0.049, p=0.005, and p=0.001, resp. and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p=0.001. The patient satisfactions of both groups were similar. Conclusion. The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities, whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading.

  11. Fifty-year follow-up and Strampelli anterior chamber intraocular lens.

    Science.gov (United States)

    Oakley, Carmen L; Nigro, Matthew A; Vote, Brendan J

    2015-01-01

    The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era. The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era.

  12. A rapid method for measuring intraocular lens power in vitro with a focimeter.

    Science.gov (United States)

    García-Domene, Mari Carmen; Díez-Ajenjo, María Amparo; Peris-Martínez, Cristina; Navea, Amparo; Artigas, José María

    2015-11-01

    In this paper we describe a new method for measuring the intraocular lens (IOL) power using a focimeter, a negative ophthalmic lens and a saline solution (0.9% NaCl). To test this we measured the power of 58 different IOLs and we compared them with the power stated by the manufacturer. Despite the limitations, the results show a good correlation.

  13. Case of late-onset corneal decompensation after iris-fixated phakic intraocular lens implantation.

    NARCIS (Netherlands)

    Eijden, R. van; Vries, N.E. de; Cruysberg, L.P.J.; Webers, C.A.; Berenschot, T.; Nuijts, R.M.

    2009-01-01

    A 48-year-old myopic patient with bilateral anterior chamber depth of 3.1 mm and endothelial cell density (ECD) of 2525 cells/mm(2) and 2638 cells/mm(2) preoperatively had bilateral implantation of an Artisan iris-fixated phakic intraocular lens (pIOL). Five years postoperatively, unilateral corneal

  14. Comparison of ocular straylight after implantation of multifocal intraocular lenses

    NARCIS (Netherlands)

    Łabuz, Grzegorz; Reus, Nicolaas J; van den Berg, Thomas J T P

    2016-01-01

    UNLABELLED: A comprehensive review of the effect of multifocal intraocular lens (IOL) designs on postoperative ocular straylight was performed. Studies reporting straylight values obtained with the natural pupil using the C-Quant device after uneventful multifocal IOL implantation were included. The

  15. Comparison of a hydrophilic and a hydrophobic apodized diffractive multifocal intraocular lens.

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2013-01-01

    To compare outcomes between a new design apodized diffractive hydrophilic multifocal intraocular lens (IOL) (Seelens MF; study group), and a well-known apodized diffractive hydrophobic multifocal IOL (SN6AD1; control group). A comparative case series comparing refractive and visual outcomes at dista

  16. Clinical comparison of the optical performance of aspheric and spherical intraocular lenses

    NARCIS (Netherlands)

    van Gaalen, Kim W.; Koopmans, Steven A.; Jansonius, Nomdo M.; Kooijman, Aart C.

    2010-01-01

    PURPOSE: To compare the optical performance of aspheric Tecnis ZA9003 and spherical Sensar AR40e intraocular lenses (IOLs). SETTING: Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. METHODS: An aspheric IOL was implan

  17. Common Genetic Determinants of Intraocular Pressure and Primary Open-Angle Glaucoma

    NARCIS (Netherlands)

    van Koolwijk, Leonieke M. E.; Ramdas, Wishal D.; Ikram, M. Kamran; Jansonius, Nomdo M.; Pasutto, Francesca; Hysi, Pirro G.; Macgregor, Stuart; Janssen, Sarah F.; Hewitt, Alex W.; Viswanathan, Ananth C.; ten Brink, Jacoline B.; Hosseini, S. Mohsen; Amin, Najaf; Despriet, Dominiek D. G.; Willemse-Assink, Jacqueline J. M.; Kramer, Rogier; Rivadeneira, Fernando; Struchalin, Maksim; Aulchenko, Yurii S.; Weisschuh, Nicole; Zenkel, Matthias; Mardin, Christian Y.; Gramer, Eugen; Welge-Luessen, Ulrich; Montgomery, Grant W.; Carbonaro, Francis; Young, Terri L.; Bellenguez, Celine; McGuffin, Peter; Foster, Paul J.; Topouzis, Fotis; Mitchell, Paul; Wang, Jie Jin; Wong, Tien Y.; Czudowska, Monika A.; Hofman, Albert; Uitterlinden, Andre G.; Wolfs, Roger C. W.; de Jong, Paulus T. V. M.; Oostra, Ben A.; Paterson, Andrew D.; Mackey, David A.; Bergen, Arthur A. B.; Reis, Andre; Hammond, Christopher J.; Vingerling, Johannes R.; Lemij, Hans G.; Klaver, Caroline C. W.; van Duijn, Cornelia M.

    2012-01-01

    Intraocular pressure (IOP) is a highly heritable risk factor for primary open-angle glaucoma and is the only target for current glaucoma therapy. The genetic factors which determine IOP are largely unknown. We performed a genome-wide association study for IOP in 11,972 participants from 4 independen

  18. Comparative evaluation of intraocular pressure changes subsequent to insertion of laryngeal mask airway and endotracheal tube.

    Directory of Open Access Journals (Sweden)

    Ghai B

    2001-07-01

    Full Text Available AIMS: To evaluate the intraocular pressure and haemodynamic changes subsequent to insertion of laryngeal mask airway and endotracheal tube. SUBJECTS AND METHODS: The study was conducted in 50 adult patients. A standard general anaesthesia was administered to all the patients. After 3 minutes of induction of anaesthesia baseline measurements of heart rate, non-invasive blood pressure and intraocular pressure were taken following which patients were divided into two groups: laryngeal mask airway was inserted in group 1 and tracheal tube in group 2. These measurements were repeated at 15-30 second, every minute thereafter up to 5 minutes after airway instrumentation. RESULTS: A statistically significant rise in heart rate, systolic blood pressure, diastolic blood pressure and intraocular pressure was seen in both the groups subsequent to insertion of laryngeal mask airway or endotracheal tube. Mean maximum increase was statistically more after endotracheal intubation than after laryngeal mask airway insertion. The duration of statistically significant pressure responses was also longer after endotracheal intubation. CONCLUSION: Laryngeal mask airway is an acceptable alternative technique for ocular surgeries, offering advantages in terms of intraocular pressure and cardiovascular stability compared to tracheal intubation.

  19. The case for intraocular delivery of PPAR agonists in the treatment of diabetic retinopathy.

    LENUS (Irish Health Repository)

    Treacy, Maxwell P

    2012-09-01

    Systemic therapeutics targeting the peroxisome proliferator-activated receptors have been found to be beneficial in the treatment of diabetic retinopathy. In this paper, we provide a rationale for the use of these therapeutics as intraocular agents. In addition, we introduce the peroxisome proliferator-activated receptors and describe their functions in response to the drugs.

  20. Associations with intraocular pressure across Europe: The European Eye Epidemiology (E3) Consortium

    NARCIS (Netherlands)

    A.P. Khawaja (Anthony); H. Springelkamp (Henriët); Creuzot-Garcher, C. (Catherine); C. Delcourt (Cécile); Hofman, A. (Albert); R. Höhn (René); O. Iglesias (Oriol); R.C.W. Wolfs (Roger); J.-F. Korobelnik (Jean-François); Silva, R. (Rufino); F. Topouzis (Fotis); K.M. Williams (Katie M.); A. Bron (Alain); G.H.S. Buitendijk (Gabrielle); Cachulo, M.L. (Maria da Luz); A. Cougnard-Grégoire (Audrey); J.-F. Dartigues; C.J. Hammond (Christopher J.); A.F.H. Pfeiffer (Andreas); Salonikiou, A. (Angeliki); van Duijn, C.M. (Cornelia M.); J.R. Vingerling (Hans); R.N. Luben (Robert); Mirshahi, A. (Alireza); Lamparter, J. (Julia); C.C.W. Klaver (Caroline); Jansonius, N.M. (Nomdo M.); P.J. Foster (Paul); On behalf of the European Eye Epidemiology (E³) Consortium,; Acar, N. (Niyazi); Anastosopoulos, E. (Eleftherios); Azuara-Blanco, A. (Augusto); A.A.B. Bergen (Arthur); G. Bertelsen (Geir); Binquet, C. (Christine); Bird, A. (Alan); L. Bretillon (Lionel); Bron, A. (Alain); Buitendijk, G. (Gabrielle); U. Chakravarthy (Usha); Chakravarthy, U. (Usha); Chan, M. (Michelle); Chang, P. (Petrus); Colijn, A. (Annemarie); Cougnard-Grégoire, A. (Audrey); C. Creuzot-Garcher (Catherine); Cumberland, P. (Philippa); Cunha-Vaz, J. (José); V. Daien (Vincent); G. Deak (Gabor); C. Delcourt (Cécile); Delyfer, M.-N. (Marie-Noëlle); Hollander, A. (Anneke den); Dietzel, M. (Martha); M.G. Erke (Maja Gran); S. Fauser (Sascha); Finger, R. (Robert); A.E. Fletcher (Astrid E.); P.J. Foster (Paul J.); Founti, P. (Panayiota); Göbel, A. (Arno); T.G.M.F. Gorgels (Theo); J. Grauslund (Jakob); Grus, F. (Franz); C.J. Hammond (Christopher); C. Helmer (Catherine); H.-W. Hense (Hans-Werner); Hermann, M. (Manuel); R. Hogg (Ruth); Hogg, R. (Ruth); Holz, F. (Frank); C. Hoyng (Carel); N.M. Jansonius (Nomdo); S.F. Janssen (Sarah); A.P. Khawaja (Anthony P.); Klaver, C. (Caroline); J.-F. Korobelnik (Jean-François); Lamparter, J. (Julia); Le Goff, M. (Mélanie); Leal, S. (Sergio); Lechanteur, Y. (Yara); T. Lehtimäki (Terho); A.J. Lotery (Andrew); Leung, I. (Irene); Mauschitz, M. (Matthias); Merle, B. (Bénédicte); E. Midena (Edoardo); Midena, E. (Edoardo); Miotto, S. (Stefania); A. Mirshahi (Alireza); Mohan-Saïd, S. (Sadek); Muldrew, A. (Alyson); Mueller, M. (Michael); Nunes, S. (Sandrina); K. Oexle (Konrad); T. Peto (Tünde); S. Piermarocchi (Stefano); E. Prokofyeva (Elena); J.S. Rahi (Jugnoo); O. Raitakari (Olli); Ribeiro, L. (Luisa); Rougier, M.-B. (Marie-Bénédicte); Sahel, J. (José); Salonikiou, A. (Aggeliki); Sanchez, C. (Clarisa); S. Schmitz-Valckenberg (Steffen); C.M.C. Schweitzer (C. M C); Segato, T. (Tatiana); Shehata, J. (Jasmin); Silva, R. (Rufino); Silvestri, G. (Giuliana); Simader, C. (Christian); E.H. Souied (Eric); Springelkamp, H. (Henriet); Tapp, R. (Robyn); Topouzis, F. (Fotis); V.J.M. Verhoeven (Virginie); Von Hanno, T. (Therese); Vujosevic, S. (Stela); K.M. Williams (Katie M.); C. Wolfram (Christian); Yip, J. (Jennifer); Zerbib, J. (Jennyfer); Zwiener, I. (Isabella)

    2016-01-01

    textabstractRaised intraocular pressure (IOP) is the most important risk factor for developing glaucoma, the second commonest cause of blindness globally. Understanding associations with IOP and variations in IOP between countries may teach us about mechanisms underlying glaucoma. We examined cross-

  1. Reference intervals for intraocular pressure measured by rebound tonometry in ten raptor species and factors affecting the intraocular pressure.

    Science.gov (United States)

    Reuter, Anne; Müller, Kerstin; Arndt, Gisela; Eule, Johanna Corinna

    2011-09-01

    Intraocular pressure (IOP) was measured with the TonoVet rebound tonometer in 10 raptor species, and possible factors affecting IOP were investigated. A complete ophthalmic examination was performed, and IOP was assessed in 2 positions, upright and dorsal recumbency, in 237 birds belonging to the families Accipitridae, Falconidae, Strigidae, and Tytonidae. Mean IOP values of healthy eyes were calculated for each species, and differences between families, species, age, sex, left and right eye, as well as the 2 body positions were evaluated. Physiologic fluctuations of IOP were assessed by measuring IOP serially for 5 days at the same time of day in 15 birds of 3 species. Results showed IOP values varied by family and species, with the following mean IOP values (mm Hg +/- SD) determined: white-tailed sea eagle (Haliaeetus albicilla), 26.9 +/- 5.8; red kite (Milvus milvus), 13.0 +/- 5.5; northern goshawk (Accipiter gentilis), 18.3 +/- 3.8; Eurasian sparrowhawk (Accipiter nisus), 15.5 +/- 2.5; common buzzard (Buteo buteo), 26.9 +/- 7.0; common kestrel (Falco tinnunculus), 9.8 +/- 2.5; peregrine falcon, (Falco peregrinus), 12.7 +/- 5.8; tawny owl (Strix aluco), 9.4 +/- 4.1; long-eared owl (Asio otus), 7.8 +/- 3.2; and barn owl (Tyto alba), 10.8 +/- 3.8. No significant differences were found between sexes or between left and right eyes. In goshawks, common buzzards, and common kestrels, mean IOP was significantly lower in juvenile birds than it was in adult birds. Mean IOP differed significantly by body position in tawny owls (P = .01) and common buzzards (P = .04). By measuring IOP over several days, mean physiologic variations of +/- 2 mm Hg were detected. Differences in IOP between species and age groups should be considered when interpreting tonometric results. Physiologic fluctuations of IOP may occur and should not be misinterpreted. These results show that rebound tonometry is a useful diagnostic tool in measuring IOP in birds of prey because it provides rapid

  2. Bayesian artificial intelligence

    CERN Document Server

    Korb, Kevin B

    2003-01-01

    As the power of Bayesian techniques has become more fully realized, the field of artificial intelligence has embraced Bayesian methodology and integrated it to the point where an introduction to Bayesian techniques is now a core course in many computer science programs. Unlike other books on the subject, Bayesian Artificial Intelligence keeps mathematical detail to a minimum and covers a broad range of topics. The authors integrate all of Bayesian net technology and learning Bayesian net technology and apply them both to knowledge engineering. They emphasize understanding and intuition but also provide the algorithms and technical background needed for applications. Software, exercises, and solutions are available on the authors' website.

  3. Artificial human vision.

    Science.gov (United States)

    Dowling, Jason

    2005-01-01

    Can vision be restored to the blind? As early as 1929 it was discovered that stimulating the visual cortex of an individual led to the perception of spots of light, known as phosphenes [1] . The aim of artificial human vision systems is to attempt to utilize the perception of phosphenes to provide a useful substitute for normal vision. Currently, four locations for electrical stimulation are being investigated; behind the retina (subretinal), in front of the retina (epiretinal), the optic nerve and the visual cortex (using intra- and surface electrodes). This review discusses artificial human vision technology and requirements, and reviews the current development projects.

  4. Spatially Resolved Artificial Chemistry

    DEFF Research Database (Denmark)

    Fellermann, Harold

    2009-01-01

    Although spatial structures can play a crucial role in chemical systems and can drastically alter the outcome of reactions, the traditional framework of artificial chemistry is a well-stirred tank reactor with no spatial representation in mind. Advanced method development in physical chemistry has...... made a class of models accessible to the realms of artificial chemistry that represent reacting molecules in a coarse-grained fashion in continuous space. This chapter introduces the mathematical models of Brownian dynamics (BD) and dissipative particle dynamics (DPD) for molecular motion and reaction...

  5. General artificial neuron

    Science.gov (United States)

    Degeratu, Vasile; Schiopu, Paul; Degeratu, Stefania

    2007-05-01

    In this paper the authors present a model of artificial neuron named the general artificial neuron. Depending on application this neuron can change self number of inputs, the type of inputs (from excitatory in inhibitory or vice versa), the synaptic weights, the threshold, the type of intensifying functions. It is achieved into optoelectronic technology. Also, into optoelectronic technology a model of general McCulloch-Pitts neuron is showed. The advantages of these neurons are very high because we have to solve different applications with the same neural network, achieved from these neurons, named general neural network.

  6. Intraocular pressure-lowering effect of oral paracetamol and its in vitro corneal penetration properties

    Directory of Open Access Journals (Sweden)

    Mohamed N

    2013-01-01

    Full Text Available Nabiel Mohamed, David MeyerDivision of Ophthalmology, Faculty of Medicine and Health Sciences, University of Stellenbosch, Cape Town, South AfricaBackground: Several studies have confirmed the ability of cannabinoids to reduce intraocular pressure. Experimental data recently demonstrated unequivocally that the analgesic effect of paracetamol is due to its indirect action on cannabinoid receptors. The question then arises as to whether paracetamol can reduce intraocular pressure via its effect on intraocular cannabinoid receptors.Methods: A 2-week, prospective, randomized, controlled, single-center, parallel-group pilot study was carried out to determine the efficacy and safety of paracetamol 1 g orally administered every 6 hours in adult patients with primary or secondary open angle glaucoma as compared with topical levobunolol 0.5% twice a day. Patient well-being was closely monitored throughout the study and focused on hepatic safety in accordance with Drug-Induced Liver Injury Network criteria. The in vitro diffusion kinetics of acetaminophen in a phosphate-buffered solution in rabbit and human corneas was also investigated, with the view to a topical application.Results: Eighteen adult patients were enrolled in the study, with nine in the topical levobunolol group and nine in the oral paracetamol group. In the levobunolol group, the mean reduction in intraocular pressure at day 7 was 7.5 mmHg (P < 0.008 and at day 14 was 9.1 mmHg (P < 0.005, from a mean baseline intraocular pressure of 29.6 mmHg. The corresponding figures for the paracetamol group were 8.8 mmHg (P < 0.0004 at day 7 and 6.5 mmHg (P < 0.004 at day 14, from a mean baseline intraocular pressure of 29.4 mmHg. Both study regimens were well tolerated. No serious treatment-related adverse events were reported in either of the treatment groups. Liver function tests, systolic/diastolic blood pressure, or heart rate remained unchanged in both groups during the 2 weeks of the study. In

  7. Hyperbaric oxygen treatment for experimental intraocular hypertension in rats: An electroretinogram detection

    Institute of Scientific and Technical Information of China (English)

    Junhui Yi; Zhengrong Peng; Qiuli Liu; Zhongqi Wu

    2007-01-01

    BACKGROUND: Hyperbaric oxygen (HBO) is used for treating glaucoma, and affirmative curative effect has been obtained. HBO can sensitively reflect the obviously heightened b wave of electroretinogram (ERG)of injured tissue.OBJECTIVE: To observe the effect of HBO treatment on retinal function of rats with acute experimental intraocular hypertension with ERG.DESIGN: Randomized controlled experiment.SETTING: Department of Ophthalmology, Third Xiangya Hospital, Central South University; Department of Hyperbaric Oxygen, Xiangya Hospital, Central South University; Department of Anatomy, Xiangya Hospital, Central South University.MATERIALS: Eighteen adult healthy Wistar rats, of either gender, weighing from 150 to 250 g, were provided by the Animal Room of Central South University. Type YLCO. 5/Ⅰ A baby hyperbaric oxygen chamber, type LMS-2A two-channel physiological recorder, type BG-1 retina exposure system, Jiangwan type Ⅰ stereotaxis instrument.METHODS: This experiment was carried out in the Central South University between March and September 2006. Eighteen healthy Wistar rats were made into models of acute experimental intraocular hypertension. Then, they were divided into two groups: model group and HBO treatment group, with 9 in each group. Following 7 days of HBO treatment, the rats in HBO treatment group were placed in Type YLCO. 5/Ⅰ A baby hyperbaric oxygen chamber, which was pressurized with pure oxygen( volume fraction 0.825 ± 0.025).The treatment pressure was 0.2 MPa. The rats in HBO treatment group daily inhaled HBO for 80 minutes within 7 days; Rats in the model group were untouched. The performance of eyes was observed under the status of intraocular hypertension. ERG was recorded before, during and 7 days after modeling,meanwhile, the recovery rate of b wave from ERG was calculated. Recovery rate of b wave from ERG=(amplitude of b wave 7 days after modeling/amplitude of b wave before modeling)× 100%.MAIN OUTCOME MEASURES: ① Performance of eyes

  8. Immediate Postoperative Intraocular Pressure Adjustment Reduces Risk of Cystoid Macular Edema after Uncomplicated Micro Incision Coaxial Phacoemulsification Cataract Surgery

    Science.gov (United States)

    Jarstad, Allison R.; Chung, Gary W.; Tester, Robert A.; Day, Linda E.

    2017-01-01

    Purpose To determine the accuracy of visual estimation of immediate postoperative intraocular pressure (IOP) following microincision cataract surgery (MICS) and the effect of immediate postoperative IOP adjustment on prevention of cystoid macular edema (CME). Setting Ambulatory surgical center. Methods Prospective, randomized analysis of 170 eyes in 135 patients with MICS, performed in a Medicare approved outpatient ambulatory surgery center. Surgical parameters included a keratome incision of 1.5 mm to 2.8 mm, topical anesthetic, case completion IOP estimation by palpation and patient visualization of light, and IOP adjustment before exiting the operating theater. IOPs were classified into three groups: low (21 to 30 mmHg). IOP measurements were repeated 1 day after surgery. Optical coherence tomography (Stratus OCT, Zeiss) was measured at 2 weeks. An increase in foveal thickness greater than 15 µm was used to indicate CME. Statistical analysis was performed using one- and two-tailed Student's t-tests. Results Mean minimal foveal thickness averaged 207.15 µm in the low pressure group, 205.14 µm in the normal IOP group, and 210.48 µm in the elevated IOP group 2 weeks following surgery. CME occurred in 14 of 170 eyes (8.2%) at 2 weeks (low IOP, 35.7%; normal IOP, 14.2%; elevated IOP, 50.0%). Change in IOP from the operating theater to 1 day after surgery was within +/−5 mmHg in 54 eyes (31.7%), elevated by 6 to 15 mmHg in 22 eyes (12.9%), and elevated more than 15 mmHg in four eyes (2.3%). IOP was reduced by 6 mmHg to 15 mmHg in 39 eyes (22.9%) and reduced by more than 15 mmHg in nine eyes (5.3%). Conclusions Immediate postoperative adjustment of IOP may prevent CME in MICS. Physicians can improve their ability to estimate postoperative IOP with experience in tonometry to verify immediate postoperative IOP. There are patient safety and economic benefits to immediate IOP adjustment in the operating theater. Synopsis Immediate postoperative IOP adjustment

  9. Experimental differentiation of intraocular masses using ultrahigh-field magnetic resonance imaging--a case series.

    Directory of Open Access Journals (Sweden)

    Karen Falke

    Full Text Available PURPOSE: The case reports presented here were compiled to demonstrate the potential for improved diagnosis and monitoring of disease progress of intraocular lesions using ultrahigh-field magnetic resonance microscopy (MRM at 7.1 Tesla. METHODS: High-resolution ex vivo ocular magnetic resonance (MR images were acquired on an ultrahigh-field MR system (7.1 Tesla, ClinScan, Bruker BioScan, Germany using a 2-channel coil with 4 coil elements and T2-weighted turbo spin echo (TSE sequences of human eyes enucleated because of different intraocular lesions. Imaging parameters were: 40×40 mm field of view, 512×512 matrix, and 700 µm slice thickness. The results were correlated with in vivo ultrasound and histology of the enucleated eyes. RESULTS: Imaging was performed in enucleated eyes with choroidal melanoma, malignant melanoma of iris and ciliary body with scleral perforation, ciliary body melanoma, intraocular metastasis of esophageal cancer, subretinal bleeding in the presence of perforated corneal ulcer, hemorrhagic choroidal detachment, and premature retinopathy with phthisis and ossification of bulbar structures. MR imaging allowed differentiation between solid and cystic tumor components. In case of hemorrhage, fluid-fluid levels were identified. Melanin and calcifications caused significant hypointensity. Microstructural features of eye lesions identified by MRM were confirmed by histology. CONCLUSION: This study demonstrates the potential of MRM for the visualization and differential diagnosis of intraocular lesions. At present, the narrow bore of the magnet still limits the use of this technology in humans in vivo. Further advances in ultrahigh-field MR imaging will permit visualization of tumor extent and evaluation of nonclassified intraocular structures in the near future.

  10. Bartonella and intraocular inflammation: a series of cases and review of literature

    Directory of Open Access Journals (Sweden)

    Kalogeropoulos C

    2011-06-01

    Full Text Available Chris Kalogeropoulos1, Ioannis Koumpoulis1, Andreas Mentis2, Chrisavgi Pappa1, Paraskevas Zafeiropoulos1, Miltiadis Aspiotis11Department of Ophthalmology, Medical School, University of Ioannina, Greece; 2Laboratory of Medical Microbiology, Hellenic Pasteur Institute, Athens, GreecePurpose: To present various forms of uveitis and/or retinal vasculitis attributed to Bartonella infection and review the impact of this microorganism in patients with uveitis.Methods: Retrospective case series study. Review of clinical records of patients diagnosed with Bartonella henselae and Bartonella quintana intraocular inflammation from 2001 to 2010 in the Ocular Inflammation Department of the University Eye Clinic, Ioannina, Greece. Presentation of epidemiological and clinical data concerning Bartonella infection was provided by the international literature.Results: Eight patients with the diagnosis of Bartonella henselae and two patients with B. quintana intraocular inflammation were identified. Since four patients experienced bilateral involvement, the affected eyes totaled 14. The mean age was 36.6 years (range 12–62. Uveitic clinical entities that we found included intermediate uveitis in seven eyes (50%, vitritis in two eyes (14.2%, neuroretinitis in one eye (7.1%, focal retinochoroiditis in one eye (7.1%, branch retinal vein occlusion (BRVO due to vasculitis in one eye (7.1%, disc edema with peripapillary serous retinal detachment in one eye (7.1%, and iridocyclitis in one eye (7.1%. Most of the patients (70% did not experience systemic symptoms preceding the intraocular inflammation. Antimicrobial treatment was efficient in all cases with the exception of the case with neuroretinitis complicated by anterior ischemic optic neuropathy and tubulointerstitial nephritis.Conclusion: Intraocular involvement caused not only by B. henselae but also by B. quintana is being diagnosed with increasing frequency. A high index of suspicion is needed because the

  11. Micromachined Artificial Haircell

    Science.gov (United States)

    Liu, Chang (Inventor); Engel, Jonathan (Inventor); Chen, Nannan (Inventor); Chen, Jack (Inventor)

    2010-01-01

    A micromachined artificial sensor comprises a support coupled to and movable with respect to a substrate. A polymer, high-aspect ratio cilia-like structure is disposed on and extends out-of-plane from the support. A strain detector is disposed with respect to the support to detect movement of the support.

  12. Artificial Gravity Research Plan

    Science.gov (United States)

    Gilbert, Charlene

    2014-01-01

    This document describes the forward working plan to identify what countermeasure resources are needed for a vehicle with an artificial gravity module (intermittent centrifugation) and what Countermeasure Resources are needed for a rotating transit vehicle (continuous centrifugation) to minimize the effects of microgravity to Mars Exploration crewmembers.

  13. Artificial Left Ventricle

    CERN Document Server

    Ranjbar, Saeed; Meybodi, Mahmood Emami

    2014-01-01

    This Artificial left ventricle is based on a simple conic assumption shape for left ventricle where its motion is made by attached compressed elastic tubes to its walls which are regarded to electrical points at each nodal .This compressed tubes are playing the role of myofibers in the myocardium of the left ventricle. These elastic tubes have helical shapes and are transacting on these helical bands dynamically. At this invention we give an algorithm of this artificial left ventricle construction that of course the effect of the blood flow in LV is observed with making beneficiary used of sensors to obtain this effecting, something like to lifegates problem. The main problem is to evaluate powers that are interacted between elastic body (left ventricle) and fluid (blood). The main goal of this invention is to show that artificial heart is not just a pump, but mechanical modeling of LV wall and its interaction with blood in it (blood movement modeling) can introduce an artificial heart closed to natural heart...

  14. Artificial intelligence and psychiatry.

    Science.gov (United States)

    Servan-Schreiber, D

    1986-04-01

    This paper provides a brief historical introduction to the new field of artificial intelligence and describes some applications to psychiatry. It focuses on two successful programs: a model of paranoid processes and an expert system for the pharmacological management of depressive disorders. Finally, it reviews evidence in favor of computerized psychotherapy and offers speculations on the future development of research in this area.

  15. Observations of artificial satellites

    Directory of Open Access Journals (Sweden)

    A. MAMMANO

    1964-06-01

    Full Text Available The following publication gives the results of photographic
    observations of artificial satellites made at Asiago during the second
    and third year of this programme. The fixed camera technique and that
    with moving film (the latter still in its experimental stage have been used.

  16. Artificial intelligence within AFSC

    Science.gov (United States)

    Gersh, Mark A.

    1990-01-01

    Information on artificial intelligence research in the Air Force Systems Command is given in viewgraph form. Specific research that is being conducted at the Rome Air Development Center, the Space Technology Center, the Human Resources Laboratory, the Armstrong Aerospace Medical Research Laboratory, the Armamant Laboratory, and the Wright Research and Development Center is noted.

  17. Clinical observation on cataract with lens subluxation treated by phacoemulsification combined with intraocular lens implanta-tion%晶状体不全脱位白内障超声乳化手术临床观察

    Institute of Scientific and Technical Information of China (English)

    原文新; 曲端; 郭哲锋

    2013-01-01

    目的:观察超声乳化白内障吸出联合人工晶体植入术治疗晶状体不全脱位白内障的疗效及安全性。方法对56例(60眼)晶状体不全脱位白内障患者采用超声乳化白内障吸出术,人工晶状体固定方式采用睫状沟缝线固定或囊袋内植入,观察术后视力及并发症等情况。结果56例(60眼)病例脱位晶状体均顺利取出,并植入人工晶状体,视力均有不同程度提高。结论超声乳化白内障吸出联合人工晶状体植入术治疗晶状体不全脱位白内障是安全有效的。%Objective To observe the efficacy and safety of phacoe-mulsification combined with intraocular lens implantation for the treatment of cataract with lens subluxation. Methods 56cases (60eyes) cataract with lens subluxation were operated by phacoemulsification,intraocular lens were fixed in ciliary sulcus with sutures or implanted in the capsular bag. The visual acuity and the postoperative complications were observed and analyzed. Results 56 cases (60 eyes) cases of dislocated lens were removed successfully,with implantation of artificial lens,visual acuity was improved in different degree. Conclusion Phacoemulsifi-cation combined with intraocular lens implantation for the treatment of dislocated lens cataract is safe and effective.

  18. Introduction to Artificial Neural Networks

    DEFF Research Database (Denmark)

    Larsen, Jan

    1999-01-01

    The note addresses introduction to signal analysis and classification based on artificial feed-forward neural networks.......The note addresses introduction to signal analysis and classification based on artificial feed-forward neural networks....

  19. Placement of a collagen glaucoma drainage device to control intraocular pressure and chronic iritis secondary to juvenile rheumatoid arthritis.

    Science.gov (United States)

    Price, Francis W; Ziemba, Steven L

    2002-01-01

    A patient with juvenile rheumatoid arthritis and chronic iritis is reported with intraocular pressure near 30 mm Hg and previous episodes of intraocular pressure as high as 50 mm Hg despite maximally tolerated medical therapy. Because of the potential risk involved with a full-thickness filtration procedure, it was decided that a nonpenetrating deep sclerectomy would be appropriate, followed by placement of a collagen glaucoma drainage device to maintain aqueous outflow. Immediately postoperatively, intraocular pressure was stabilized. At 24 months postoperatively, intraocular pressure was well controlled at 15 mm Hg with patient receiving only Lotemax. No significant complications were noted at any point in the postoperative course. Because of the patient's predisposition for serious complications frequently associated with trabeculectomy, nonpenetrating deep sclerectomy with the collagen glaucoma drainage device was an effective alternative for this patient.

  20. [The effect of crystalline lens extraction on intraocular pressure in patients with primary open-angle glaucoma].

    Science.gov (United States)

    Macarie, S; Macarie, Daniela

    2013-01-01

    This issue presents the results of a study on patients with cataract and primary open angle glaucoma who suffered lens extraction for cataract. We analise the effects of the lens extraction on the level of intraocular pressure at this patients.

  1. Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Ya-wen Guo

    2014-01-01

    Full Text Available Purpose. To investigate the intraocular straylight value after cataract surgery. Methods. In this study, 76 eyes from 62 patients were subdivided into three groups. A hydrophobic acrylic, a hydrophilic acrylic, and a PMMA IOL were respectively, implanted in 24 eyes, 28 eyes, and 24 eyes. Straylight was measured using C-Quant at 1 week and 1 month postoperatively in natural and dilated pupils. Results. The hydrophilic acrylic IOLs showed significantly lower straylight values than those of the hydrophobic acrylic IOLs in dilated pupils at 1 week and 1 month after surgery (P0.05. Moreover, no significant difference was found in straylight between natural and dilated pupils in each group at 1 week and 1 month postoperatively (P>0.05. Conclusions. Although the hydrophobic acrylic IOL induced more intraocular straylight, straylight differences among the 3 IOLs were minimal. Pupil size showed no effect on intraocular straylight; the intraocular straylight was stable 1 week after surgery.

  2. Interaktive tavler - interaktive elever

    DEFF Research Database (Denmark)

    Reusch, Charlotte F.; Otzen, Elsebeth

    2012-01-01

    Abstract, Poster-præsentation 13.-14. juni 2012, Pilotprojekt: Interaktive tavler – interaktive elever Lektor, cand. pæd., Elsebeth Otzen og Lektor, cand. mag., Charlotte Reusch, Institut for Skole og Læring, Læreruddannelsen, Professionshøjskolen Metropol, København Hvordan motiverer en interaktiv...... tavle lærere og elever? Hvad sker der mellem elev, stof og lærer, når læreren bliver i stand til at billedliggøre og dynamisere sine oplæg på tavlen? Bliver læreroplæg prioriteret? Bliver eleverne aktive, eller ender den interaktive tavle med blot at understøtte lærerens envejskommunikation til klassen......? Og hvad sker der mellem eleverne? Disse spørgsmål var igangsættende for arbejdet med pilotprojektet Interaktive tavler – interaktive elever, som blev afviklet i skoleåret 2010-2011. Projektet blev udført af en tværfaglig gruppe, bestående af lektorer i matematik, biologi og dansk i læreruddannelsen...

  3. Interaktive tavler - interaktive elever

    DEFF Research Database (Denmark)

    Reusch, Charlotte; Otzen, Elsebeth

    2012-01-01

    Abstract, Poster-præsentation 13.-14. juni 2012, Pilotprojekt: Interaktive tavler ? interaktive elever Lektor, cand. pæd., Elsebeth Otzen og Lektor, cand. mag., Charlotte Reusch, Institut for Skole og Læring, Læreruddannelsen, Professionshøjskolen Metropol, København Hvordan motiverer en interaktiv...... tavle lærere og elever? Hvad sker der mellem elev, stof og lærer, når læreren bliver i stand til at billedliggøre og dynamisere sine oplæg på tavlen? Bliver læreroplæg prioriteret? Bliver eleverne aktive, eller ender den interaktive tavle med blot at understøtte lærerens envejskommunikation til klassen......? Og hvad sker der mellem eleverne? Disse spørgsmål var igangsættende for arbejdet med pilotprojektet Interaktive tavler ? interaktive elever, som blev afviklet i skoleåret 2010-2011. Projektet blev udført af en tværfaglig gruppe, bestående af lektorer i matematik, biologi og dansk i læreruddannelsen...

  4. Udeskole og elevers handlekompetence

    DEFF Research Database (Denmark)

    Breiting, Søren

    2011-01-01

    Elever elsker at komme væk fra undervisningen i skolen. Er det positivt eller negativt? Og hvad har betydning for, at eleverne får mest muligt ud af oplevelserne uden for skolen? Forskellige former for udeskole giver nogle oplagte muligheder, så eleverne udvikler sig som engagerede borgere i et...

  5. Thinning in artificially regenerated young beech stands

    Directory of Open Access Journals (Sweden)

    Novák Jiří

    2015-12-01

    Full Text Available Although beech stands are usually regenerated naturally, an area of up to 5,000 ha year−1 is artificially regenerated by beech in the Czech Republic annually. Unfortunately, these stands often showed insufficient stand density and, consequently, lower quality of stems. Therefore, thinning methods developed for naturally regenerated beech stands are applicable with difficulties. The paper evaluates the data from two thinning experiments established in young artificially regenerated beech stands located in different growing conditions. In both experiments, thinning resulted in the lower amount of salvage cut in following years. Positive effect of thinning on periodic stand basal area increment and on periodic diameter increment of dominant trees was found in the beech stand located at middle elevations. On the other hand, thinning effects in mountain conditions were negligible. Thinning focusing on future stand quality cannot be commonly applied in artificially regenerated beech stands because of their worse initial quality and lower density. However, these stands show good growth and response to thinning, hence their management can be focused on maximising beech wood production.

  6. INTRAOCULAR TRANSMISSIBLE VENEREAL TUMOR IN A DOG TUMOR VENÉREO TRANSMISSÍVEL INTRA-OCULAR EM CÃO

    Directory of Open Access Journals (Sweden)

    Geórgia Nadalini Rodrigues

    2001-02-01

    Full Text Available Canine transmissible venereal tumor (TVT is a round cell neoplasm occurring on the external genital mucosa of male and female dogs. Transmission is by cell implantation during coitus, licking, or other interaction between an affected dog and a susceptible host. Metastasis of the tumor rarely occurs. This report describes an unusual presentation of TVT with intraocular involvement and inguinal lymph nodes metastasis. The subject was a six-year-old, intact, male, Brazilian Terrier dog with a history of abnormal masses in the right eye, penis and several subcutaneous nodules in the inguinal area. Histopathological examination of the eye specimens as well as cytologic examination of penile mass and subcutaneous nodules revealed similar findings. The examination revealed round cells containing a large nuclei with prominent, central located nucleoli and a pale cytoplasm containing few small, clear round vacuoles. Histologically, the subcutaneous nodules in the inguinal area were lymph nodes. The diagnosis of TVT with intraocular involvement and lymph nodes metastasis was based on clinical, cytologic and histopathologic findings.Tumor venéreo transmissível (TVT é uma neoplasia de células redondas que acomete a mucosa genital externa de cães, machos e fêmeas. A transmissão decorre da implantação de células tumorais durante o coito, brigas ou interações entre animais portadores e susceptíveis. Existem relatos referindo-se a localizações atípicas do TVT, mas metástases raramente ocorrem. O presente relato descreve um caso incomum de TVT, com acometimento intra-ocular e metástases nos linfonodos ingüinais, num cão Terrier Brasileiro, com seis anos de idade. O animal apresentava massas anormais de tecido no olho direito, extremidade do pênis e aumento de volume de linfonodos da região ingüinal. A histopatologia do globo ocular e as citologias da massa peniana e dos nódulos subcutâneos evidenciaram aspectos citológicos semelhantes

  7. Combined Surgical Approach of Pars Plana Vitrectomy, Phacoemulsification, and Intraocular Lens Implantation for the Management of Cataract and Posterior Segment Pathologies

    Directory of Open Access Journals (Sweden)

    Cem Özgönül

    2014-03-01

    Full Text Available Objectives: To evaluate the indications, intra- and post-operative complications, and visual results of combined cataract surgery and pars plana vitrectomy. Materials and Methods: Medical records of patients who underwent combined surgery between January 2008 and January 2011 were retrospectively evaluated. Indications for surgery, complications, pre-operative and post-operative visual acuities were recorded. Results: Sixty-four eyes of 64 patients were included in the study. Thirty-five (55% of the patients were men and 29 (45% were women; mean age was 53±21 (6-88 years. Mean follow-up time was 13±12 (1-51 months. The main indications for combined surgery were intravitreal hemorrhage in 19 patients (29.7%, epiretinal membrane in 12 (18.8%, intraocular foreign body in 11 (17.2%, retinal detachment in 9 (14.1%, and macular edema in 7 (11% patients. Posterior capsule rupture in 3 cases and corneal edema in 2 cases were the complications encountered during surgery. Postoperatively, hypotonia occurred in 5 cases and corneal edema in 1. Intraocular pressure elevation was observed in 1 silicon-injected case and 1 propane gas-injected case. The average preoperative visual acuity was 1.90±1.9 (0.22 to 3.10 LogMAR. The average postoperative visual acuity at the last visit was 1.1±1.0 (0.00 to 4.00 LogMAR. The visual acuity increase was statistically significant (p<0.001. Conclusion: Combined surgery is a feasible option for patients with vitreoretinal diseases and cataract. Visual results and complications depend primarily on the underlying posterior segment pathology. (Turk J Ophthalmol 2014; 44: 98-101

  8. Aderência in vitro do Staphylococcus epidermidis e da Pseudomonas alcaligenes em lentes intra-oculares In vitro adherence of Staphylococcus epidermidis and Pseudomonas alcaligenes to intraocular lenses

    Directory of Open Access Journals (Sweden)

    Patrícia Ioschpe Gus

    2006-06-01

    Full Text Available OBJETIVO: Quantificar e comparar a aderência in vitro das bactérias Staphylococcus epidermidis e Pseudomonas alcaligenes em diferentes tipos de lentes intra-oculares (LIOs. MÉTODOS: Quatorze lentes intra-oculares foram usadas no experimento. Quatro de polimetilmetacrilato (PMMA, quatro de silicone, quatro de hidrogel e duas de acrílico. Oito lentes intra-oculares foram colocadas em oito tubos de ensaio contendo 4 ml de suspensão de Pseudomonas alcaligenes, e seis lentes intra-oculares foram colocadas em seis tubos de ensaio contendo 4 ml de suspensão de Staphylococcus epidermidis. A concentração do caldo utilizada para o teste de aderência foi de 10(8 unidades formadoras de colônias por mililitro (CFU/mL que corresponde a 0,5 na escala de McFarland. As lentes foram incubadas a 37° por duas horas. Após, foram removidas dos caldos e enxaguadas em água destilada estéril por duas vezes. As lentes foram cultivadas em placas de ágar-sangue a 35-37° e evaliadas a cada 24h por um período de 72h. Nas amostras que tiveram crescimento bacteriano, foram contadas as colônias utilizando os métodos convencionais de laboratório. Todos os ensaios foram executados em duplicata. RESULTADOS: A aderência do Staphylococcus epidermidis nas lentes de PMMA foi menor se comparada com as de silicone e de hidrogel. A aderência daPseudomonas alcaligenes nas lentes de hidrogel foi menor se comparada com as de silicone, PMMA e acrílico. CONCLUSÃO: Os resultados sugerem que a aderência do Staphylococcus epidermidis e da Pseudomonas alcaligenes nas lentes intra-oculares é influenciada pelo tipo de material da lente e pela espécie do microorganismo. A aderência bacteriana pode ter papel importante na patogenicidade da endoftalmite pós-cirurgia de catarata.PURPOSE: To quantify and compare the in vitro adherence of Staphylococcus epidermidis and Pseudomonas alcaligenes to different intraocular lenses (IOLs. METHODS: Fourteen intraocular lenses were

  9. Artificial Enzymes, "Chemzymes"

    DEFF Research Database (Denmark)

    Bjerre, Jeannette; Rousseau, Cyril Andre Raphaël; Pedersen, Lavinia Georgeta M;

    2008-01-01

    Enzymes have fascinated scientists since their discovery and, over some decades, one aim in organic chemistry has been the creation of molecules that mimic the active sites of enzymes and promote catalysis. Nevertheless, even today, there are relatively few examples of enzyme models...... that successfully perform Michaelis-Menten catalysis under enzymatic conditions (i.e., aqueous medium, neutral pH, ambient temperature) and for those that do, very high rate accelerations are seldomly seen. This review will provide a brief summary of the recent developments in artificial enzymes, so called...... "Chemzymes", based on cyclodextrins and other molecules. Only the chemzymes that have shown enzyme-like activity that has been quantified by different methods will be mentioned. This review will summarize the work done in the field of artificial glycosidases, oxidases, epoxidases, and esterases, as well...

  10. Artificial neural network modelling

    CERN Document Server

    Samarasinghe, Sandhya

    2016-01-01

    This book covers theoretical aspects as well as recent innovative applications of Artificial Neural networks (ANNs) in natural, environmental, biological, social, industrial and automated systems. It presents recent results of ANNs in modelling small, large and complex systems under three categories, namely, 1) Networks, Structure Optimisation, Robustness and Stochasticity 2) Advances in Modelling Biological and Environmental Systems and 3) Advances in Modelling Social and Economic Systems. The book aims at serving undergraduates, postgraduates and researchers in ANN computational modelling. .

  11. Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Kapil Nahar

    2012-12-01

    Full Text Available An artificial neural network is an information-processing paradigm that is inspired by the way biological nervous systems, such as the brain, process information.The key element of this paradigm is the novel structure of the information processing system. It is composed of a large number of highly interconnected processing elements (neurons working in unison to solve specific problems.Ann’s, like people, learn by example.

  12. Essentials of artificial intelligence

    CERN Document Server

    Ginsberg, Matt

    1993-01-01

    Since its publication, Essentials of Artificial Intelligence has beenadopted at numerous universities and colleges offering introductory AIcourses at the graduate and undergraduate levels. Based on the author'scourse at Stanford University, the book is an integrated, cohesiveintroduction to the field. The author has a fresh, entertaining writingstyle that combines clear presentations with humor and AI anecdotes. At thesame time, as an active AI researcher, he presents the materialauthoritatively and with insight that reflects a contemporary, first hand

  13. Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Kapil Nahar

    2012-12-01

    Full Text Available An artificial neural network is an information-processing paradigm that is inspired by the way biological nervous systems, such as the brain, process information. The key element of this paradigm is the novel structure of the information processing system. It is composed of a large number of highly interconnected processing elements (neurons working in unison to solve specific problems. Ann’s, like people, learn by example.

  14. Artificial sweetener; Jinko kanmiryo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    The patents related to the artificial sweetener that it is introduced to the public in 3 years from 1996 until 1998 are 115 cases. The sugar quality which makes an oligosaccharide and sugar alcohol the subject is greatly over 28 cases of the non-sugar quality in the one by the kind as a general tendency of these patents at 73 cases in such cases as the Aspartame. The method of manufacture patent, which included new material around other peptides, the oligosaccharide and sugar alcohol isn`t inferior to 56 cases of the formation thing patent at 43 cases, and pays attention to the thing, which is many by the method of manufacture, formation. There is most improvement of the quality of sweetness with 31 cases in badness of the aftertaste which is characteristic of the artificial sweetener and so on, and much stability including the improvement in the flavor of food by the artificial sweetener, a long time and dissolution, fluid nature and productivity and improvement of the economy such as a cost are seen with effect on a purpose. (NEDO)

  15. ARTIFICIAL INSEMINATION IN BOVINE

    Directory of Open Access Journals (Sweden)

    A. L. M Marinho

    2016-02-01

    Full Text Available This literature review aims to show the main scientific advances achieved in the area of Artificial Insemination (AI within animal reproduction and how these can improve reproductive efficiency and productive of the Brazilian cattle herd. With knowledge of the mechanisms involved in the control of reproductive physiology, in levels endocrine, cellular and molecular, it was possible the development of reproductive biotechnologies, standing out the IA, It has been used on a large scale, by allow the multiplication of animals superior genetically , increase the birthrate and be particularly effective in adjusting the breeding season in cattle. Artificial insemination has an important role in animal genetic improvement; it is the main and more viable middle of spread of genes worldwide when compared to other methods how technologies of embryos and the natural breeding. There are several advantages in using artificial insemination in herd both of cutting as milkman, as herd genetic improvement in lesser time and at a low cost through the use of semen of demonstrably superior sires for production, well as in the control and decrease of diseases which entail reproductive losses and consequently productive, by allowing the creator The crossing of zebuine females with bulls of European breeds and vice-versa, through the use of semen, increasing the number of progeny of a reproducer superior

  16. Bottom-up fabrication of zwitterionic polymer brushes on intraocular lens for improved biocompatibility

    Science.gov (United States)

    Han, Yuemei; Xu, Xu; Tang, Junmei; Shen, Chenghui; Lin, Quankui; Chen, Hao

    2017-01-01

    Intraocular lens (IOL) is an efficient implantable device commonly used for treating cataracts. However, bioadhesion of bacteria or residual lens epithelial cells on the IOL surface after surgery causes postoperative complications, such as endophthalmitis or posterior capsular opacification, and leads to loss of sight again. In the present study, zwitterionic polymer brushes were fabricated on the IOL surface via bottom-up grafting procedure. The attenuated total reflection-Fourier transform infrared and contact angle measurements indicated successful surface modification, as well as excellent hydrophilicity. The coating of hydrophilic zwitterionic polymer effectively decreased the bioadhesion of lens epithelial cells or bacteria. In vivo intraocular implantation results showed good in vivo biocompatibility of zwitterionic IOL and its effectiveness against postoperative complications. PMID:28053528

  17. Cluster headache: interictal asymmetric increment in intraocular pressure elicited by Valsalva manoeuvre.

    Science.gov (United States)

    Barriga, F J; Sánchez-del-Río, M; Barón, M; Dobato, J l; Gili, P; Yangüela, J; Bueno, A; Pareja, J A

    2004-03-01

    Changes in intraocular pressure (IOP) elicited by a Valsalva manoeuvre were studied in 11 male patients (mean age 39.8 years) suffering from episodic cluster headache (CH), and 12 healthy male controls (mean age 39.9 years). The tests were performed at rest and while exhaling hard through a mouthpiece connected to a mercury manometer. In the CH group, during symptomatic periods, between attacks, Valsalva manoeuvre elicited an asymmetric increase in IOP with significantly higher values on the symptomatic side (P = 0011), whereas no asymmetric increments in IOP were found during asymptomatic periods. Outside the cluster period the IOP values both baseline and with Valsalva manoeuvre did not differ from controls. The increment in IOP took place within a few seconds, as in spontaneous CH attacks, thus pointing to a rapid increase in intraocular blood volume or vasodilatation. These findings may reflect a latent increased vascular reactivity of the symptomatic orbit during CH period.

  18. Closure of a persistent cyclodialysis cleft using the haptics of a normal-sized intraocular lens.

    Science.gov (United States)

    Shentu, Xingchao; Zhu, Yanan; Tang, Yelei

    2011-11-01

    A 50-year-old man suffering from hypotony in the right eye caused by a traumatic cyclodialysis and complicated by a choroidal detachment and cataract was treated in our clinic. After an unsuccessful direct cyclopexy, phacoemulsification was performed and a normal-sized single-piece polymethyl methacrylate posterior chamber intraocular lens (PMMA PCIOL) was inserted into the ciliary sulcus, with the haptic rotated toward the cyclodialysis cleft. Postoperatively, the corrected visual acuity improved to 20/20, and the intraocular pressure returned to normal. Ultrasound biomicroscopy showed the closure of the cleft. Phacoemulsification with a normal-sized PMMA PCIOL inserted into the ciliary sulcus is a safe, effective and technically simple surgical treatment for small cyclodialysis induced hypotony complicated by cataract. Internal compression of the cleft by the haptic of a normal sized IOL along with postoperative inflammation led to scarring and closure of the cleft.

  19. Effects of intraocular mescaline and LSD on visual-evoked responses in the rat.

    Science.gov (United States)

    Eells, J T; Wilkison, D M

    1989-01-01

    The effects of mescaline and LSD on the flash-evoked cortical potential (FEP) were determined in unrestrained rats with chronically-implanted electrodes. Systemic administration of mescaline or LSD significantly attenuated the primary component of the FEP at three stimulus intensities with the greatest effect observed 60-90 minutes following drug administration. The magnitude and specificity of the effects of these agents on the primary response suggest that they produce deficits in conduction through the retino-geniculato-cortical system. The serotonin receptor antagonists, cyproheptadine and methysergide, antagonized the mescaline-induced depression of the FEP in accordance with neurochemical and behavioral evidence that mescaline acts as a partial agonist on serotonin receptors. Topical or intraocular administration of atropine antagonized the actions of systemically-administered mescaline. In addition, intraocular administration of mescaline or LSD attenuated the FEP indicative of an action of these hallucinogens on visual processing in the retina which is modulated by muscarinic receptor activity.

  20. Implantation of iris-claw Artisan intraocular lens for aphakia in Fuchs′ heterochromic iridocyclitis

    Directory of Open Access Journals (Sweden)

    Ahmad Kheirkhah

    2014-01-01

    Full Text Available Implantation of iris-claw Artisan intraocular lens (IOL is a surgical option for correction of aphakia; however, these IOLs have not been used in eyes with uveitis including Fuchs′ heterochromic iridocyclitis (FHI due to possible risk of severe postoperative intraocular inflammation. In the case reported here, we secondarily implanted an Artisan IOL in a 28-year-old man with FHI who had aphakia with no capsular support due to a previous complicated cataract surgery. Enclavation was easily performed and no intraoperative complication was noted. Postoperative course was uneventful with no significant anterior chamber inflammation during 12 months of follow-up. Although there were few deposits on the IOL surface, the patient achieved a best-corrected visual acuity of 20/20 without developing glaucoma or other complications. Therefore, Artisan IOL may be considered for correction of aphakia in patients with FHI. However, studies on large number of patients are required to evaluate safety of the procedure.

  1. Delivery of Intraocular Triamcinolone Acetonide in the Treatment of Macular Edema

    Directory of Open Access Journals (Sweden)

    Brent Siesky

    2012-03-01

    Full Text Available Macular edema (ME is one of the eventual outcomes of various intraocular and systemic pathologies. The pathogenesis for ME is not yet entirely understood; however, some of the common risk factors for its development have been identified. While this investigation will not discuss the numerous etiologies of ME in detail, it appraises the two most widely studied delivery modalities of intraocular corticosteroids in the treatment of ME—intravitreal injection (IVI and sub-Tenon’s infusion (STI. A thorough review of the medical literature was conducted to identify the efficacy and safety of IVI and STI, specifically for the administration of triamcinolone acetonide (TA, in the setting of ME in an attempt to elucidate a preferred steroid delivery modality for treatment of ME.

  2. The Changes of Quality of Life in the Patients after Phacoemulsification with Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Jiewei Liu; Jingjing Xu; Mingguang He

    2004-01-01

    Purpose: To investigate the improvement and maintenance of the quality of life in the patients after phacoemulsification with intraocular lens implantation.Methods :The study population consisted of 116 patients receiving phacoemulsification with intraocular lens implantation. They were interviewed using the quality of life questionnaire, and the clinical outcomes were evaluated before surgery and at 1 week, 1month, 3 months, 6 months after surgery respectively.Results:Patients reported similar scores of quality of life and all the four subscales among 1-week, 1-month , 3-month and 6-month follow-up visit after surgery, all of which were higher than the scores before surgery.Conclusion: Patients receiving phacoemulsification reported rapid improvement in quality of life after surgery, and the quality of life scores were not changed significantly from 1week to 6 months after surgery.

  3. Biocompatibility of intraocular lens materials%人工晶体材料的生物相容性特征★

    Institute of Scientific and Technical Information of China (English)

    王洋; 韩宏光

    2013-01-01

      BACKGROUND: The visual recovery and complications of the cataract patients are various after different intraocular lens materials implantation, so the selection of appropriate intraocular lens materials is the key of the research. OBJECTIVE: To investigate the properties and biocompatibility of intraocular lens materials. METHODS: The materials were classified according to the hardness and location of the intraocular lens after implantation in order to analyze the pros and cons of the intraocular lens thus guiding the patients to select the appropriate intraocular lens for implantation. The properties and biocompatibility of the commonly used intraocular lens materials were evaluated. RESUTLS AND CONCLUSION: Polymethylmethacrylate intraocular lens is the first choice of rigid material, but it cannot tolerate autoclaving. Acrylic intraocular lens is the soft and foldable intraocular lens that has the similar optical and biological properties with polymethylmethacrylate intraocular lens, and it can improve the visual acuity after implantation with less complications. Posterior capsular opacification is the most important indicator for biocompatibility evaluation which is related with the material and design of intraocular lens. The stability of intraocular lens in the capsular bag is also the indicator to evaluate the biocompatibility. The material properties, biocompatibility, and visual function should be taking into consideration in the design and selection of intraocular lens materials. Guarantee the efficacy after intraocular lens implantation and reduce the incidence of complications, so that to get vision rehabilitation for the cataract patients.%  背景:白内障患者植入不同材料人工晶体治疗后的视力恢复情况和并发症有所不同,选择适宜的人工晶体材料是研究的关键。目的:探讨人工晶体材料的特征和生物相容性。方法:按人工晶体的硬度和植入后不同位置将材料进行分类

  4. Artificial sweeteners--do they bear a carcinogenic risk?

    Science.gov (United States)

    Weihrauch, M R; Diehl, V

    2004-10-01

    Artificial sweeteners are added to a wide variety of food, drinks, drugs and hygiene products. Since their introduction, the mass media have reported about potential cancer risks, which has contributed to undermine the public's sense of security. It can be assumed that every citizen of Western countries uses artificial sweeteners, knowingly or not. A cancer-inducing activity of one of these substances would mean a health risk to an entire population. We performed several PubMed searches of the National Library of Medicine for articles in English about artificial sweeteners. These articles included 'first generation' sweeteners such as saccharin, cyclamate and aspartame, as well as 'new generation' sweeteners such as acesulfame-K, sucralose, alitame and neotame. Epidemiological studies in humans did not find the bladder cancer-inducing effects of saccharin and cyclamate that had been reported from animal studies in rats. Despite some rather unscientific assumptions, there is no evidence that aspartame is carcinogenic. Case-control studies showed an elevated relative risk of 1.3 for heavy artificial sweetener use (no specific substances specified) of >1.7 g/day. For new generation sweeteners, it is too early to establish any epidemiological evidence about possible carcinogenic risks. As many artificial sweeteners are combined in today's products, the carcinogenic risk of a single substance is difficult to assess. However, according to the current literature, the possible risk of artificial sweeteners to induce cancer seems to be negligible.

  5. Management of posteriorly dislocated endocapsular tension ring and intraocular lens complex.

    Science.gov (United States)

    Deka, Satyen; Deka, Amarendra; Bhattacharjee, Harsha

    2006-05-01

    We report a case of late posteriorly dislocated endocapsular tension ring (ECR) and intraocular lens (IOL) complex into the vitreous cavity that behaved as a single 13 mm disc. A 3-port pars plana vitrectomy was performed, and perfluorocarbon liquid was used to retrieve the ECR-IOL complex to the retropupillary area. A 3-point scleral fixation was performed to reposition the inseparable ECR-IOL complex.

  6. Changes in intraocular pressure following administration of suxamethonium and endotracheal intubation: Influence of dexmedetomidine premedication

    OpenAIRE

    Chandan Kumar Pal; Manjushree Ray; Anjana Sen; Bimal Hajra; Dipankar Mukherjee; Anil Kumar Ghanta

    2011-01-01

    Background: Use of suxamethonium is associated with an increase in intraocular pressure (IOP) and may be harmful for patients with penetrating eye injuries. The purpose of our study was to observe the efficacy of dexmedetomidine for prevention of rise in IOP associated with the administration of suxamethonium and endotracheal intubation. Methods: Sixty-six American Society of Anaesthesiologists I or II patients undergoing general anaesthesia for non-ophthalmic surgery were included in this ra...

  7. Evaluation of in vitro glistening formation in hydrophobic acrylic intraocular lenses

    OpenAIRE

    Thomes BE; Callaghan TA

    2013-01-01

    Brett E Thomes, Thomas A CallaghanAlcon Research Ltd (A Novartis Company), Fort Worth, TX, USAPurpose: To evaluate the impact of continuous manufacturing process improvements on glistening formation in AcrySof hydrophobic acrylic intraocular lenses (IOLs) by comparing lenses manufactured in 2003 with lenses manufactured in 2012.Methods: Glistenings were experimentally created as aqueous-filled microvacuoles utilizing an accelerated laboratory method by immersing the lens in water at 45&de...

  8. Correlation of the intraocular pressure with increased intracranial pressure in rabbits

    Directory of Open Access Journals (Sweden)

    Eskandari H

    2000-08-01

    Full Text Available Although measurement of intracranial pressure by noninvasive methods has been suggested, but mainly invasive methods are used for this purpose-Increase in episcleral venous pressure can be expected to result in a linear increase in intraocular pressure. Congested oculat veins with capillary leakage and hemorrhage are seen when the ICP is increased, thus theoretically measurement of intraocular pressure can be a procedure for estimation of the ICP. This study was performed to find whether there is andy relationship between intraocular pressure and ICP, so we used 12 albino rabbits in two divided groups. Our study was not designed to elucidate the mechanism of change but merely to record any changes observed. All measures except an increase in ICP were applied on the test group as well as on the control group. After general anesthesia with the combination of ketamin, rampune, and pentobarbital a burr hole was made in the lambda region of the skull and a cannula was placed in the subdural space. The ICP in the test group increased up to 15 mmHg and was constant throughout the experiment. Intraocular pressure was measured by Schiotz tonometers afte general anesthesia, after cannulation of the skull, and immediately after increasing the ICP which was repated in 15 minutes interval for 4 hours. There was no statistical difference between the two groups (P:0.997 . results show that neither cannulation nor general anesthesia for 4 hours produce alteration in IOP in the control group nor increasing of the ICP to level of 15 mmHg produces any alteration in IOP on the test group.

  9. [Iris suture fixation of posterior-chamber elastic intraocular lens in ligament apparatus laxity].

    Science.gov (United States)

    Pashtaev, N P; Bat'kov, E N; Zotov, V V

    2010-01-01

    An original MIOL-23 multifocal elastic intraocular lens (IOL) was used to operate 5 eyes with acquired lens dislocation and traumatic cataract. By making self-sealing tunnel incision, ILO was implanted into the capsular sac and sutured to the iris. MIOL-23 implantation caused an increase in mean visual acuity. The IOL took up a correct position. Elastic IOL implantation with iris suture fixation is an efficient and safe mode of additional ILO support.

  10. Congenital cataract surgery with intraocular lens implantation in microphthalmic eyes: visual outcomes and complications

    Directory of Open Access Journals (Sweden)

    Marcelo Carvalho Ventura

    2013-08-01

    Full Text Available PURPOSE: To report the visual outcomes and complications of congenital cataract surgery with primary intraocular lens implantation in microphthalmic eyes of children younger than 4 years of age. METHODS:This retrospective interventional case series included 14 microphthalmic eyes from 10 children who underwent congenital cataract surgery with primary intraocular lens implantation younger than 4 years of age. Seven patients had bilateral cataracts (11 eyes met the study's inclusion criteria and 3 patients had unilateral cataract. Patients' medical charts were reviewed to obtain information regarding the preoperative and postoperative ophthalmological examination. Main outcome measures were intraocular pressure (IOP, best-corrected visual acuity, and intraoperative and postoperative complications. RESULTS: Mean age at the time of surgery was 21.7 ± 2.9 months. Mean ocular axial length was 19.2 ± 0.9 mm. Mean preoperative IOP was 9.7 ± 1.7 mmHg and 10.3 ± 3.1 mmHg on final follow-up (P=0.18. There were no intraoperative complications. Two (15.4% eyes developed secondary visual axis opacification, of which only one needed to be reoperated due to significantly decreased vision (0.5 logMAR. Preoperative and postoperative best-corrected visual acuity was 2.09 ± 0.97 logMAR and 0.38 ± 0.08 logMAR in bilateral cases and 1.83 ± 1.04 logMAR and 0.42 ± 0.13 logMAR in unilateral cases, respectively. CONCLUSION: Primary intraocular lens implantation in congenital cataract surgery in microphthalmic eyes resulted in a significant best-corrected visual acuity improvement with no intraoperative complications and minimal postoperative complications.

  11. Surgical management of spontaneous in-the-bag intraocular lens and capsular tension ring complex dislocation

    Directory of Open Access Journals (Sweden)

    Uzeyir Gunenc

    2014-01-01

    Full Text Available We describe a technique to manage late spontaneous intraocular lens (IOL and capsular tension ring (CTR dislocation within the intact capsular bag. The subluxated IOL and CTR complex can be positioned in a closed chamber and fixed to the pars plana at both 3 and 9 o′clock quadrants with the presented ab externo direct scleral suturation technique which provides an easy, safe and effective surgical option for such cases.

  12. Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK

    Directory of Open Access Journals (Sweden)

    Benjamin Botsford

    Full Text Available ABSTRACT Purpose: To compare the effect of 20% sulfur hexafluoride (SF6 with that of air on graft detachment rates for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK. Methods: Forty-two eyes of patients who underwent DMEK by a single surgeon (A.S.J. at Wilmer Eye Institute between January 2012 and 2014 were identified; 21 received air for intraocular tamponade and the next consecutive 21 received SF6. The main outcome measure was the graft detachment rate; univariate and multivariate analyses were performed. Results: The graft detachment rate was 67% in the air group and 19% in the SF6 group (p<0.05. No complete graft detachments occurred, and all partial detachments underwent intervention with injection of intraocular air. The percentages of eyes with 20/25 or better vision were not different between the groups (67% vs. 71%. Univariate analysis showed significantly higher detachment rates with air tamponade (OR, 8.50; p<0.005 and larger donor graft size (OR, 14.96; p<0.05. Multivariate analysis with gas but not graft size included showed that gas was an independent statistically significant predictor of outcome (OR, 6.65; p<0.05. When graft size was included as a covariate, gas was no longer a statistically significant predictor of detachment but maintained OR of 7.81 (p=0.063 similar to the results of univariate and multivariate analyses without graft size. Conclusion: In comparison with air, graft detachment rates for intraocular tamponade in DMEK were significantly reduced by 20% SF6.

  13. New Management of Angle-closure Glaucoma by Phacoemulsification with Foldable Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Jian Ge; Yan Guo; Yizhi Liu; Mingkai Lin; Yehong Zhuo; Bing Chen; Xiuqi Chen

    2000-01-01

    Objective: To investigate the management of angle-closure glaucoma by phacoemulsification with foldable posterior chamber intraocular lens (PC-IOL) implantation. Design: Retrospective, noncontrolled interventional case series.Participants: In 36 eyes with angle-closure glaucoma (ACG), there were 18 eyes with primary acute angle-closure glaucoma (PACG), 14 eyes with primary chronic angle-closure glaucoma (PCCG), 3 eyes with secondary acute angle-closure glaucoma (SACG) and 1 eye with secondary chronic angle-closure glaucoma (SCCG).Intervention: Phacoemulsification with posterior chamber intraocular lens implantation.Main Outcome Measures: Postoperative visual acuity, IOP, axial anterior chamber depth.Results: After a mean postoperative follow-up time of 8.81 ± 7.45 months, intraocular pressure was reduced from a preoperative mean of 23.81 ± 17.84 mmHg to a postoperative mean of 12.54 ± 4. 73 mmHg ( P = 0. 001 ). Mean anterior chamber depth was 1.75 ± 0.48 mm preoperatively and 2.29 ± 0.38 mm postoperatively ( P = 0. 000).Best spectacle-corrected visual acuity in 36 eyes ranged from 0. 01 to 0. 7 (20/200 to 20/30) postoperatively, which was better than preoperative VA ranging from hand movement to 0.4 (20/50) ( P= 0. 000).Conclusion: Phacoemulsification with posterior chamber foldable intraocular lens implantation can be a good alternative in treating angle-closure glaucoma. Eye Science 2000; 16:22 ~ 28.

  14. New Management of Angle-closure Glaucoma by Phacoemulsification with Folable Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    JianGE; YanGuo; 等

    2002-01-01

    Objective:To investigate the management of angle-closure glaucoma by phacoemulsification with foldable posterior chamber intraocular lens (PC-IOIL)implantation.Design:Retrospective,noncontrolled interventional case series.Participants:In 36 eyes with angle -closure glaucoma(ACG).there were 18eyes with primary acute angle-closure glaucoma(PACG),14 eyes with primary chonic angle -closure glaucoma(PCCG),3 eyes with secondary acute angle-closure glaucoma (SACG) and 1 eye with secondary chronic angle -closure glaucoma(SCCG).Intervention:Phacoemulsification with posterior chamber intraocular lens implantation.Main Outcome Measures:Postoperative visual acuity,IOP,axial anterior chamber depth.Results:After a mean postoperative follow -time of 8.81±7.45 months,intraocular pressure was reduced from a preoperative mean of 23.81±17.84 mmHg to a postoperative mean of 12.54±4.73mmHg(P=0.001).Mean anterior chamber depth was 1.75±0.48 mm preoiperatively and 2.29±0.38mm postoperatively(P-0.000).Best spectacle-corrected visual acuity in 36 eyes ranged from 0.01 to 0.7(20/200 to 20/30)postoperatively,which was better than preoperative VA ranging from hand movement to 0.4(20/50)(P=0.000).Conclusion:Phacoemulsification with posterior chamber foldable intraocular lens implantation can be a good alternative in treating angle-closure glaucoma.Eye Science2000;16:22-28.

  15. Skuldertesten "Kombineret Elevation"

    DEFF Research Database (Denmark)

    Clausen, Mikkel Bek; Overkær, Brian

    2010-01-01

    Formål: At udarbejde en testprotokol for testen Kombineret Elevation (KE) og undersøge test-retest variationen ved test af elite svømmere, samt diskutere testens relevans og validitet. Materiale og Metode: 9 elite og 10 sub-elite svømmere, heraf var 11 mænd og 8 kvinder, gennemførte testen KE 2...

  16. Clinical utility and differential effects of prostaglandin analogs in the management of raised intraocular pressure and ocular hypertension

    Directory of Open Access Journals (Sweden)

    Anne J Lee

    2010-07-01

    Full Text Available Anne J Lee1,2, Peter McCluskey2,31Manchester Royal Eye Hospital, Manchester, UK; 2University of Sydney, Sydney, Australia; 3Sydney Eye Hospital, Sydney, AustraliaAbstract: Prostaglandin analogs (PGA are powerful topical ocular hypotensive agents available for the treatment of elevated intraocular pressure (IOP. Latanoprost 0.005% and travoprost 0.004% are prodrugs and analogs of prostaglandin F2a. Bimatoprost 0.03% is regarded as a prostamide, and debate continues as to whether it is a prodrug. The free acids of all 3 PGAs reduce IOP by enhancing uveoscleral and trabecular outflow via direct effects on ciliary muscle relaxation and remodeling of extracellular matrix. The vast majority of clinical trials demonstrate IOP-lowering superiority of latanoprost, bimatoprost and travoprost compared with timolol 0.5%, brimonidine 0.2%, or dorzolamide 2% monotherapy. Bimatoprost appears to be more efficacious in IOP-lowering compared with latanoprost, with weighted mean difference in IOP reduction documented in one meta-analysis of 2.59% to 5.60% from 1- to 6-months study duration. PGAs reduce IOP further when used as adjunctive therapy. Fixed combinations of latanoprost, bimatoprost or travoprost formulated with timolol 0.5% and administered once daily are superior to monotherapy of its constituent parts. PGA have near absence of systemic side effects, although do have other commonly encountered ocular adverse effects. The adverse effects of PGA, and also those found more frequently with bimatoprost use include ocular hyperemia, eyelash growth, and peri-ocular pigmentary changes. Iris pigmentary change is unique to PGA treatment. Once daily administration and near absence of systemic side effects enhances tolerance and compliance. PGAs are often prescribed as first-line treatment for ocular hypertension and open-angle glaucoma.Keywords: prostaglandin analog, glaucoma, ocular hypertension, latanoprost, bimatoprost, travoprost

  17. EFFECT OF AEROBIC EXERCISE OF MODERATE INTENSITY AND SHORT DURATION ON INTRAOCULAR PRESSURE IN YOUNG INDIVIDUALS

    Directory of Open Access Journals (Sweden)

    Syamala Devi

    2014-08-01

    Full Text Available Intra-ocular pressure (IOP in normal individuals varies throughout the night and day. The diurnal variation for normal eyes is between 3 and 6mmHg and the variation may increase in glaucomatous eyes. Hence, the present effort is to investigate the effect of moderate exercise on intraocular pressure changes. IOP was measured before and after exercise in 100 subjects (50M, 50F with no ocular abnormality with ages ranging from 18-21 years by using Schiotz tonometer. Weight, height and body mass index, were recorded. The results obtained were compared between before-and-after-exercise of the subjects. The data were presented as the mean ± SD, Student’s t-test was used to calculate significance between means. The IOP showed a statistically significant fall following moderate exercise. The mean IOP significantly decreased (p0.05 decreased after 60 minutes of aerobic exercise. Gender wise comparison of intraocular pressure both before and after exercise did not reveal much significance. Physical exercise, such as jogging, walking and bicycle riding, could be suggested as a complimentary therapy in addition to the pharmaceutical and surgical therapies available for glaucoma patients, even though the mechanism for lowering IOP is not clear enough.

  18. Two cases of uveitis masquerade syndrome caused by bilateral intraocular large B-cell lymphoma

    Directory of Open Access Journals (Sweden)

    Jovanović Svetlana

    2013-01-01

    Full Text Available Introduction. Sometimes it is not easy to clinically recognize subtle differences between intraocular lymphoma and noninfectious uveitis. The most common lymphoma subtype involving the eye is B-cell lymphoma. Case report. We presented two patients aged 59 and 58 years with infiltration of the subretinal space with a large B-cell non-Hodgkin intraocular lymphoma. The patients originally had clinically masked syndrome in the form of intermediate uveitis. As it was a corticosteroid-resistant uveitis, we focused on the possible diagnosis of neoplastic causes of this syndrome. During hospitalization, the neurological symptoms emerged and multiple subretinal changes accompanied by yellowish white patches of retinal pigment epithelium with signs of vitritis, which made us suspect the intraocular lymphoma. Endocranial magnetic resonance imaging established tumorous infiltration in the region of the left hemisphere of the cerebellum. The histopathological finding confirmed the diagnosis of large B-cell non-Hodgkin lymphoma of risk moderate degree, immunoblast - centroblast cytological type. The other patient had clinical chronic uveitis accompanied by yellowish shaped white echographic changes of the retina and localized changes in the level of the subretina. The diagnosis of lymphoma was made by brain biopsy. Conclusion. Uveitis masquerade syndrome should be considered in all patients over 40 years with idiopathic steroid-resistant uveitis. Treatment begun on time can affect the course and improve the prognosis of uveitis masquerade syndrome (UMS and systemic disease.

  19. Retropupillary Fixation of Iris-Claw Intraocular Lens for Aphakic Eyes in Children.

    Directory of Open Access Journals (Sweden)

    Martina Brandner

    Full Text Available To report outcome, complications and safety of retropupillary fixated iris-claw intraocular lenses in a pediatric population.Retrospective study.Ten consecutive pediatric patients (15 eyes underwent placement of retropupillary fixated iris-claw intraocular lenses between October 2007 and July 2013 at the Department of Ophthalmology, Medical University Graz and General Hospital Klagenfurt, Austria. Postoperative visual acuity and complications were analyzed.Median final best-corrected visual acuity improved by 0.12 logMAR from preoperative baseline. Mean postoperative spherical equivalent was -0.05 ± 1.76 D. No serious complications were observed intra- or postoperatively during the entire follow-up period of up to 40 months. One patient experienced a haptic disenclavation with IOL subluxation immediately after a car accident.Our study demonstrates that iris-claw intraocular lens implantation behind the iris is safe in children with lack of capsular support and yields excellent visual outcome with low complication rate.

  20. Stereoselectivity of satropane, a novel tropane analog, on iris muscarinic receptor activation and intraocular hypotension

    Institute of Scientific and Technical Information of China (English)

    Liang ZHU; Hong-zhuan CHEN; Li-min YANG; Yong-yao CUI; Pei-li ZHENG; Yin-yao NIU; Hao WANG; Yang LU; Qiu-shi REN; Pi-jing WEI

    2008-01-01

    Aim: To study the stereoselectivity of satropane (3-paramethylbenzene sulfonyloxy-6-acetoxy tropane), a novel tropane analog, on iris muscarinic receptor activation and intraocular hypotension. Methods: The assays for radioligand-receptor binding, the contractile responses of isolated iris muscle, the miosis response, and the intraocular hypotension of the enantiomers of satropane were investigated. Results: In the binding analysis, S(-)satropane (lesatropane) completely com-peted against the [3H]quinuclydinyl benzilate-labeled ligand at muscarinic recep-tors in the iris muscle, whereas R(+)satropane failed to completely compete. In an isolated iris contractile assay, R,S(±)satropane and S(-)satropane produced a concentration-dependent contractile response with similar efficacy and potency to that of carbachol. R(+)satropane did not induce any contractile response. In the pupil diameter measurement assay in vivo, S(-)satropane induced miosis much more effectively than pilocarpine, while R(+)satropane failed to produce any miosis. In the water loading-induced and methylcellulose-induced ocular hypertensive models, S(-)satropane, but not R(+)satropane, significantly suppressed intraocu-lar pressure at a much lower concentration than pilocarpine. Conclusion: The ago-nistic and hypotensive properties of satropane on rabbit eyes are stereoselective, with the S(-)isomer being its active form.

  1. Acute Central Retinal Artery Occlusion Associated with Intraocular Silicone Oil Tamponade

    Directory of Open Access Journals (Sweden)

    Mehmet Yasin Teke

    2012-05-01

    Full Text Available Many systemic and ocular factors may cause acute central retinal artery occlusion (CRAO. Herein, we aimed to describe a case of CRAO due to intraocular silicone oil (SO tamponade. To the best of our knowledge, a case like our has not been reported previously. A 58-yearold male patient had undergone combined pars plana vitrectomy-lensectomy and intraocular SO for lens luxation and vitreus hemorrhage associated with a blunt ocular trauma in his right eye. Two weeks after the surgery, he presented with acute vision loss in the same eye. He was diagnosed with acute CRAO and it should be related with mechanical press or raised intraocular pressure (IOP associated with SO. He was treated by partial removal of SO immediately. In spite of the regression of retina edema, his visual acuity did not improve due to optic atrophy. SO may cause CRAO due to raised IOP and/or its mechanical pressure and this complication must be kept in mind. (Turk J Oph thal mol 2012; 42: 238-40

  2. Optical aberrations of intraocular lenses measured in vivo and in vitro

    Science.gov (United States)

    Barbero, Sergio; Marcos, Susana; Jiménez-Alfaro, Ignacio

    2003-10-01

    Corneal and ocular aberrations were measured in a group of eyes before and after cataract surgery with spherical intraocular lens (IOL) implantation by use of well-tested techniques developed in our laboratory. By subtraction of corneal from total aberration maps, we also estimated the optical quality of the intraocular lens in vivo. We found that aberrations in pseudophakic eyes are not significantly different from aberrations in eyes before cataract surgery or from previously reported aberrations in healthy eyes of the same age. However, aberrations in pseudophakic eyes are significantly higher than in young eyes. We found a slight increase of corneal aberrations after surgery. The aberrations of the IOL and the lack of balance of the corneal spherical aberrations by the spherical aberrations of the intraocular lens also degraded the optical quality in pseudophakic eyes. We also measured the aberrations of the IOL in vitro, using an eye cell model, and simulated the aberrations of the IOL on the basis of the IOL's physical parameters. We found a good agreement among in vivo, in vitro, and simulated measures of spherical aberration: Unlike the spherical aberration of the young crystalline lens, which tends to be negative, the spherical aberration of the IOL is positive and increases with lens power. Computer simulations and in vitro measurements show that tilts and decentrations might be contributors to the increased third-order aberrations in vivo in comparison with in vitro measurements.

  3. Lente intra-ocular opaca em diplopia intratável: relato de caso Opaque intraocular lens in intractable diplopia: case report

    Directory of Open Access Journals (Sweden)

    Fernanda Teixeira Krieger

    2006-08-01

    Full Text Available Diplopia intratável tem sido descrita em várias situações. Métodos convencionais como prismas e correção cirúrgica do estrabismo falham em neutralizá-la. O objetivo do trabalho é documentar o caso de uma paciente com estrabismo de longa data, cuja diplopia deteriorou-se ao longo dos anos, e não foi possível resolução com cirurgia, prisma, e oclusão com óculos e lente de contato com pupila opaca. A paciente foi então submetida à facoemulsificação com implante de lente intra-ocular opaca que atingiu o objetivo desejado.Intractable diplopia has been described in many situations but poor results are the rule with standard treatment modalities. The authors report a case of a woman with long-standing strabismus and diplopia who failed to improve following surgery, prism, and occlusive spectacles or contact lenses. Then, she was submitted to phacoemulsification and opaque intraocular lens implantation, which successfully neutralized diplopia.

  4. Artificial intelligence in hematology.

    Science.gov (United States)

    Zini, Gina

    2005-10-01

    Artificial intelligence (AI) is a computer based science which aims to simulate human brain faculties using a computational system. A brief history of this new science goes from the creation of the first artificial neuron in 1943 to the first artificial neural network application to genetic algorithms. The potential for a similar technology in medicine has immediately been identified by scientists and researchers. The possibility to store and process all medical knowledge has made this technology very attractive to assist or even surpass clinicians in reaching a diagnosis. Applications of AI in medicine include devices applied to clinical diagnosis in neurology and cardiopulmonary diseases, as well as the use of expert or knowledge-based systems in routine clinical use for diagnosis, therapeutic management and for prognostic evaluation. Biological applications include genome sequencing or DNA gene expression microarrays, modeling gene networks, analysis and clustering of gene expression data, pattern recognition in DNA and proteins, protein structure prediction. In the field of hematology the first devices based on AI have been applied to the routine laboratory data management. New tools concern the differential diagnosis in specific diseases such as anemias, thalassemias and leukemias, based on neural networks trained with data from peripheral blood analysis. A revolution in cancer diagnosis, including the diagnosis of hematological malignancies, has been the introduction of the first microarray based and bioinformatic approach for molecular diagnosis: a systematic approach based on the monitoring of simultaneous expression of thousands of genes using DNA microarray, independently of previous biological knowledge, analysed using AI devices. Using gene profiling, the traditional diagnostic pathways move from clinical to molecular based diagnostic systems.

  5. Polymer artificial muscles

    Directory of Open Access Journals (Sweden)

    Tissaphern Mirfakhrai

    2007-04-01

    Full Text Available The various types of natural muscle are incredible material systems that enable the production of large deformations by repetitive molecular motions. Polymer artificial muscle technologies are being developed that produce similar strains and higher stresses using electrostatic forces, electrostriction, ion insertion, and molecular conformational changes. Materials used include elastomers, conducting polymers, ionically conducting polymers, and carbon nanotubes. The mechanisms, performance, and remaining challenges associated with these technologies are described. Initial applications are being developed, but further work by the materials community should help make these technologies applicable in a wide range of devices where muscle-like motion is desirable.

  6. Mechanism of artificial heart

    CERN Document Server

    Yamane, Takashi

    2016-01-01

    This book first describes medical devices in relation to regenerative medicine before turning to a more specific topic: artificial heart technologies. Not only the pump mechanisms but also the bearing, motor mechanisms, and materials are described, including expert information. Design methods are described to enhance hemocompatibility: main concerns are reduction of blood cell damage and protein break, as well as prevention of blood clotting. Regulatory science from R&D to clinical trials is also discussed to verify the safety and efficacy of the devices.

  7. Uncertainty in artificial intelligence

    CERN Document Server

    Kanal, LN

    1986-01-01

    How to deal with uncertainty is a subject of much controversy in Artificial Intelligence. This volume brings together a wide range of perspectives on uncertainty, many of the contributors being the principal proponents in the controversy.Some of the notable issues which emerge from these papers revolve around an interval-based calculus of uncertainty, the Dempster-Shafer Theory, and probability as the best numeric model for uncertainty. There remain strong dissenting opinions not only about probability but even about the utility of any numeric method in this context.

  8. Bayesian artificial intelligence

    CERN Document Server

    Korb, Kevin B

    2010-01-01

    Updated and expanded, Bayesian Artificial Intelligence, Second Edition provides a practical and accessible introduction to the main concepts, foundation, and applications of Bayesian networks. It focuses on both the causal discovery of networks and Bayesian inference procedures. Adopting a causal interpretation of Bayesian networks, the authors discuss the use of Bayesian networks for causal modeling. They also draw on their own applied research to illustrate various applications of the technology.New to the Second EditionNew chapter on Bayesian network classifiersNew section on object-oriente

  9. Visual performance after the implantation of a new trifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Vryghem JC

    2013-10-01

    Full Text Available Jérôme C Vryghem,1,2 Steven Heireman1,21Brussels Eye Doctors, Brussels, Belgium; 2Clinique Saint-Jean, Brussels, BelgiumPurpose: To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens.Methods: A new trifocal diffractive intraocular lens was designed combining two superimposed diffractive profiles: one with +1.75 diopters (D addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that were operated on by one surgeon are included in this study. The uncorrected and best distance-corrected monocular and binocular, near, intermediate, and distance visual acuities, contrast sensitivity, and defocus curves were measured 6 months postoperatively. In addition to the standard clinical follow-up, a questionnaire evaluating individual satisfaction and quality of life was submitted to the patients.Results: The mean age of patients at the time of surgery was 70 ± 10 years. The mean uncorrected and corrected monocular distance visual acuity (VA were LogMAR 0.06 ± 0.10 and LogMAR 0.00 ± 0.08, respectively. The outcomes for the binocular uncorrected distance visual acuity were almost the same (LogMAR −0.04 ± 0.09. LogMAR −010 ± 0.15 and 0.02 ± 0.06 were measured for the binocular uncorrected intermediate and near VA, respectively. The distance-corrected visual acuity was maintained in mesopic conditions. The contrast sensitivity was similar to that obtained after implantation of a bifocal intraocular lens and did not decrease in mesopic conditions. The binocular defocus curve confirms good VA even in the intermediate distance range, with a moderate decrease of less than LogMAR 0.2 at −1.5 D, with respect to the best distance VA at 0 D defocus. Patient satisfaction was high. No discrepancy between the objective and subjective outcomes was evidenced.Conclusion: The introduction of a third focus in diffractive multifocal

  10. The relationship between cytokine level and nitric oxide content in aqueous humor after intraocular lens implantation

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    AIM: To investigate the relationship between cytokine level and nitric oxide (NO) content in aqueous humor after intraocular lens implantation. METHODS: All New Zealand rabbits were divided randomly into three groups: (1) control group, (2) extracapsular cataract extraction group (ECCE), (3) extracapsular cataract extraction and posterior chamber intraocular lens implantation group (ECCE+IOL). The inflammation of all experimental rabbit eyes, including cornea edema and anterior chamber exudation were observed via zoom-photo slitlamp microscope 1,3,7,14,30 d postoperation. Meanwhile, aqueous humor was drawn for white blood cell (WBC) counting and classifying, and for NO-2/NO-3 and cytokine assay, including interleukin-2(IL-2), tumour necrosis factor-α(TNF-α). Statistics were taken by SPSS softwear. RESULTS: (1) Total WBC in aqueous humor were higher and anterior chamber exudation were more severe in ECCE+IOL group than that in ECCE group and control group. (2) The level of IL-2 and TNF-α and the content of NO-2/NO-3 in aqueous humor of ECCE+IOL group were higher than that in ECCE group and control group 1-14 d postoperation respectively, and it increased to peak value at 3-7 d postoperation and decreased gradually after two weeks postoperation. (3) The change regularity of IL-2, TNF-α and NO-2/NO-3 in each group were basically similar, i.e. when the level of cytokine (IL-2 and TNF-α) was normal, the content of NO-2/NO-3 was normal too, when the level of cytokine (IL-2 and TNF-α) increased, the content of NO-2/NO-3 increased too. CONCLUSION: The intraocular inflammation after ECCE+IOL was more severe than that after simple ECCE. NO, IL-2 and TNF-α play an important role in intraocular inflammation after intraocular lens implantation. The changes of IL-2 and TNF-α level was closely related with NO content in aqueous humor.

  11. Artificial Intelligence in Space Platforms.

    Science.gov (United States)

    1984-12-01

    computer algorithms, there still appears to be a need for Artificial Inteligence techniques in the navigation area. The reason is that navigaion, in...RD-RI32 679 ARTIFICIAL INTELLIGENCE IN SPACE PLRTFORNSMU AIR FORCE 1/𔃼 INST OF TECH WRIGHT-PRTTERSON AFB OH SCHOOL OF ENGINEERING M A WRIGHT DEC 94...i4 Preface The purpose of this study was to analyze the feasibility of implementing Artificial Intelligence techniques to increase autonomy for

  12. Trimaran Resistance Artificial Neural Network

    Science.gov (United States)

    2011-01-01

    11th International Conference on Fast Sea Transportation FAST 2011, Honolulu, Hawaii, USA, September 2011 Trimaran Resistance Artificial Neural Network Richard...Trimaran Resistance Artificial Neural Network 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e... Artificial Neural Network and is restricted to the center and side-hull configurations tested. The value in the parametric model is that it is able to

  13. Parallel artificial liquid membrane extraction

    DEFF Research Database (Denmark)

    Gjelstad, Astrid; Rasmussen, Knut Einar; Parmer, Marthe Petrine

    2013-01-01

    This paper reports development of a new approach towards analytical liquid-liquid-liquid membrane extraction termed parallel artificial liquid membrane extraction. A donor plate and acceptor plate create a sandwich, in which each sample (human plasma) and acceptor solution is separated by an arti...... by an artificial liquid membrane. Parallel artificial liquid membrane extraction is a modification of hollow-fiber liquid-phase microextraction, where the hollow fibers are replaced by flat membranes in a 96-well plate format....

  14. How to teach artificial organs.

    Science.gov (United States)

    Zapanta, Conrad M; Borovetz, Harvey S; Lysaght, Michael J; Manning, Keefe B

    2011-01-01

    Artificial organs education is often an overlooked field for many bioengineering and biomedical engineering students. The purpose of this article is to describe three different approaches to teaching artificial organs. This article can serve as a reference for those who wish to offer a similar course at their own institutions or incorporate these ideas into existing courses. Artificial organ classes typically fulfill several ABET (Accreditation Board for Engineering and Technology) criteria, including those specific to bioengineering and biomedical engineering programs.

  15. [Artificial neural networks in Neurosciences].

    Science.gov (United States)

    Porras Chavarino, Carmen; Salinas Martínez de Lecea, José María

    2011-11-01

    This article shows that artificial neural networks are used for confirming the relationships between physiological and cognitive changes. Specifically, we explore the influence of a decrease of neurotransmitters on the behaviour of old people in recognition tasks. This artificial neural network recognizes learned patterns. When we change the threshold of activation in some units, the artificial neural network simulates the experimental results of old people in recognition tasks. However, the main contributions of this paper are the design of an artificial neural network and its operation inspired by the nervous system and the way the inputs are coded and the process of orthogonalization of patterns.

  16. Development of artificial empathy.

    Science.gov (United States)

    Asada, Minoru

    2015-01-01

    We have been advocating cognitive developmental robotics to obtain new insight into the development of human cognitive functions by utilizing synthetic and constructive approaches. Among the different emotional functions, empathy is difficult to model, but essential for robots to be social agents in our society. In my previous review on artificial empathy (Asada, 2014b), I proposed a conceptual model for empathy development beginning with emotional contagion to envy/schadenfreude along with self/other differentiation. In this article, the focus is on two aspects of this developmental process, emotional contagion in relation to motor mimicry, and cognitive/affective aspects of the empathy. It begins with a summary of the previous review (Asada, 2014b) and an introduction to affective developmental robotics as a part of cognitive developmental robotics focusing on the affective aspects. This is followed by a review and discussion on several approaches for two focused aspects of affective developmental robotics. Finally, future issues involved in the development of a more authentic form of artificial empathy are discussed.

  17. Creating an Artificial Muscle

    Science.gov (United States)

    Bohon, Katherine; Krause, Sonja

    1997-03-01

    Striated skeletal muscle responds to a nerve impulse in less than 100 ms. In the past, polymeric gels and conducting polymers have been investigated for use as artificial muscle. However, the main problem with these materials is their relatively slow response (>3 seconds). On the other hand, electrorheological (ER) fluids are materials that change from a liquid to a solid upon application of an electric field. These fluids have a response on the order of a millisecond. A novel approach to artificial muscle utilizing the fast time response of ER fluids and the elasticity of polymeric gels has been investigated. A commercial sample of a two-part poly(dimethyl siloxane) (PDMS) dielectric gel was used. The PDMS was cured around two flexible electrodes 5 mm apart while a mixture of PDMS with solvent was cured between the electrodes. The solvents were either silicone oil or an ER fluid composed of crosslinked poly(ethylene oxide) (PEO) particles in silicone oil. The mixtures investigated were 90/10, 60/40, 50/50, 40/60, 10/90 PDMS/solvent. Upon application of a 6.2 kV/cm DC electric field the gel was reversibly compressed. The time response of the gel was actuator has been created using the 60/40 PDMS/ER fluid mixture.

  18. The total artificial heart.

    Science.gov (United States)

    Cook, Jason A; Shah, Keyur B; Quader, Mohammed A; Cooke, Richard H; Kasirajan, Vigneshwar; Rao, Kris K; Smallfield, Melissa C; Tchoukina, Inna; Tang, Daniel G

    2015-12-01

    The total artificial heart (TAH) is a form of mechanical circulatory support in which the patient's native ventricles and valves are explanted and replaced by a pneumatically powered artificial heart. Currently, the TAH is approved for use in end-stage biventricular heart failure as a bridge to heart transplantation. However, with an increasing global burden of cardiovascular disease and congestive heart failure, the number of patients with end-stage heart failure awaiting heart transplantation now far exceeds the number of available hearts. As a result, the use of mechanical circulatory support, including the TAH and left ventricular assist device (LVAD), is growing exponentially. The LVAD is already widely used as destination therapy, and destination therapy for the TAH is under investigation. While most patients requiring mechanical circulatory support are effectively treated with LVADs, there is a subset of patients with concurrent right ventricular failure or major structural barriers to LVAD placement in whom TAH may be more appropriate. The history, indications, surgical implantation, post device management, outcomes, complications, and future direction of the TAH are discussed in this review.

  19. Prótese intra-ocular de resina acrílica em cães e gatos Acrylic resin intraocular prosthesis in dogs and cats

    Directory of Open Access Journals (Sweden)

    S.C. Rahal

    2000-08-01

    Full Text Available Foram atendidos no Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Unesp - Campus de Botucatu, 11 animais (oito cães e três gatos, com alterações oftálmicas unilaterais graves que levaram à perda total da função ocular (protrusão de globo com injúria nervosa e estrutural, perfurações de córnea com perda de conteúdo intra-ocular e endoftalmites, entre outras. Os animais, com idades entre dois meses e 10 anos, foram submetidos à evisceração e posterior inclusão de esfera de resina acrílica (metilmetacrilato na capa córneo-escleral ou escleral. As esferas foram previamente confeccionadas e esterilizadas por autoclavagem. No pós-operatório foram utilizados antiinflamatórios e antibioticoterapia tópica combinada ou não a sistêmica. O período de observação variou de 2 meses a 3 anos e os aspectos avaliados foram secreção ocular, blefarospasmo, sinais de desconforto e estética. Obtiveram-se resultados satisfatórios em oito casos. Concluiu-se que a resina acrílica pode ser uma alternativa para uso como inclusão em cavidade anoftálmica.Eleven animals (eight dogs and three cats, aged between two months and ten years were referred to the Veterinary Hospital of Faculty of Veterinary Medicine and Animal Science - Unesp, Botucatu, Brazil. These animals presented severe unilateral ophthalmic changes that lead to a total loss of ocular function, such as prolapsed eyes with nervous and structural injury, corneal damage with loss of intraocular contents or endophthalmitis among others. They were submitted to evisceration followed by the insertion of an acrylic resin prosthesis (methylmethacrylate in the corneoscleral or scleral shell. The spheres were previously made and sterilized by autoclave. The postoperative medical therapy included topical and systemic broad-spectrum antibiotics for seven days and anti-inflammatory drugs. The follow-up time varied from two months to three years. The evaluated

  20. Generative Artificial Intelligence : Philosophy and Theory of Artificial Intelligence

    NARCIS (Netherlands)

    van der Zant, Tijn; Kouw, Matthijs; Schomaker, Lambertus; Mueller, Vincent C.

    2013-01-01

    The closed systems of contemporary Artificial Intelligence do not seem to lead to intelligent machines in the near future. What is needed are open-ended systems with non-linear properties in order to create interesting properties for the scaffolding of an artificial mind. Using post-structuralistic

  1. Specific features of measuring the optical power of artificial refractive and diffractive-refractive eye lenses

    Science.gov (United States)

    Lenkova, G. A.

    2016-08-01

    Methods for monitoring the optical power of artificial refractive eye lenses (intraocular lenses) based on measuring focal lengths in air and in medium are analyzed. The methods for determining the refraction of diffractive-refractive lenses (in particular, of MIOL-Akkord type), with allowance for the specific features of the diffractive structure, are considered. A computer simulation of the measurement of the focal length of MIOL-Akkord lenses is performed. The effective optical power of the diffractive component of these lenses is shown to depend on the diaphragm diameter. The optimal diaphragm diameter, at which spherical aberrations do not affect the position of foci, is found to be 3 mm. Possible errors in measuring the focal lengths are analyzed, and the necessary corrections that must be introduced into measurement results and calculations of refractions are determined.

  2. Aderência bacteriana in vitro a lentes intra-oculares de polimetilmetacrilato e de silicone In vitro bacterial adherence to silicone and polymetylmethacrylate intraocular lenses

    Directory of Open Access Journals (Sweden)

    Claudete Inês Locatelli

    2004-04-01

    Full Text Available OBJETIVOS: Verificar a aderência bacteriana a lentes intra-oculares de silicone e de polimetilmetacrilato como possível fator de risco no desenvolvimento de endoftalmite pós-operatória, utilizando-se um modelo in vitro com três microrganismos potencialmente patogênicos. MÉTODOS: As análises foram realizadas com cepas de Staphylococcus aureus ATCC 29213, Staphylococcus epidermidis (amostra clínica e Pseudomonas aeruginosa ATCC 27853 incluindo a determinação de curvas de crescimento, testes para verificação de produção de cápsula, avaliação da hidrofobicidade, testes de aderência a diferentes materiais, microscopia óptica, microscopia eletrônica de varredura e microscopia de força atômica. RESULTADOS: A produção de cápsula e a aderência das três diferentes cepas não mostraram qualquer relação com a quantidade de microrganismos; em relação às lentes intra-oculares de polimetilmetacrilato e de silicone, não houve diferença estatisticamente significativa na aderência de S. aureus e S. epidermidis; P. aeruginosa foi o microrganismo mais aderente a ambos os materiais. A microscopia eletrônica de varredura confirmou estes achados em relação à aderência, ao peso que a microscopia de força atômica evidenciou a produção de biofilme pelas cepas de S. aureus, S. epidermidis e P. aeruginosa. CONCLUSÕES: Constatou-se, in vitro, que os materiais analisados não diferiram com relação à taxa de aderência bacteriana, porém, P. aeruginosa apresentou maior eficiência de adesão entre as bactérias testadas. Todas as cepas produziram biofilme. Silicone foi o material mais hidrofóbico, quando comparado ao polimetilmetacrilato.PURPOSE: To evaluate bacterial adherence to silicone and polymetylmethacrylate (PMMA intraocular lenses as a risk factor for postsurgery endophthalmitis by using an in vitro model with three potentially pathogenic microorganisms. METHODS: In vitro experiments were carried out with the

  3. Artificial Diets for Mosquitoes

    Directory of Open Access Journals (Sweden)

    Kristina K. Gonzales

    2016-12-01

    Full Text Available Mosquito-borne diseases are responsible for more than a million human deaths every year. Modern mosquito control strategies such as sterile insect technique (SIT, release of insects carrying a dominant lethal (RIDL, population replacement strategies (PR, and Wolbachia-based strategies require the rearing of large numbers of mosquitoes in culture for continuous release over an extended period of time. Anautogenous mosquitoes require essential nutrients for egg production, which they obtain through the acquisition and digestion of a protein-rich blood meal. Therefore, mosquito mass production in laboratories and other facilities relies on vertebrate blood from live animal hosts. However, vertebrate blood is expensive to acquire and hard to store for longer times especially under field conditions. This review discusses older and recent studies that were aimed at the development of artificial diets for mosquitoes in order to replace vertebrate blood.

  4. Artificial Immune Systems (2010)

    CERN Document Server

    Greensmith, Julie; Aickelin, Uwe

    2010-01-01

    The human immune system has numerous properties that make it ripe for exploitation in the computational domain, such as robustness and fault tolerance, and many different algorithms, collectively termed Artificial Immune Systems (AIS), have been inspired by it. Two generations of AIS are currently in use, with the first generation relying on simplified immune models and the second generation utilising interdisciplinary collaboration to develop a deeper understanding of the immune system and hence produce more complex models. Both generations of algorithms have been successfully applied to a variety of problems, including anomaly detection, pattern recognition, optimisation and robotics. In this chapter an overview of AIS is presented, its evolution is discussed, and it is shown that the diversification of the field is linked to the diversity of the immune system itself, leading to a number of algorithms as opposed to one archetypal system. Two case studies are also presented to help provide insight into the m...

  5. Sucrose compared with artificial sweeteners

    DEFF Research Database (Denmark)

    Sørensen, Lone Brinkmann; Vasilaras, Tatjana H; Astrup, Arne;

    2014-01-01

    There is a lack of appetite studies in free-living subjects supplying the habitual diet with either sucrose or artificially sweetened beverages and foods. Furthermore, the focus of artificial sweeteners has only been on the energy intake (EI) side of the energy-balance equation. The data are from...

  6. Instructional Applications of Artificial Intelligence.

    Science.gov (United States)

    Halff, Henry M.

    1986-01-01

    Surveys artificial intelligence and the development of computer-based tutors and speculates on the future of artificial intelligence in education. Includes discussion of the definitions of knowledge, expert systems (computer systems that solve tough technical problems), intelligent tutoring systems (ITS), and specific ITSs such as GUIDON, MYCIN,…

  7. A Primer on Artificial Intelligence.

    Science.gov (United States)

    Leal, Ralph A.

    A survey of literature on recent advances in the field of artificial intelligence provides a comprehensive introduction to this field for the non-technical reader. Important areas covered are: (1) definitions, (2) the brain and thinking, (3) heuristic search, and (4) programing languages used in the research of artificial intelligence. Some…

  8. Generalized Adaptive Artificial Neural Networks

    Science.gov (United States)

    Tawel, Raoul

    1993-01-01

    Mathematical model of supervised learning by artificial neural network provides for simultaneous adjustments of both temperatures of neurons and synaptic weights, and includes feedback as well as feedforward synaptic connections. Extension of mathematical model described in "Adaptive Neurons For Artificial Neural Networks" (NPO-17803). Dynamics of neural network represented in new model by less-restrictive continuous formalism.

  9. Artificial Ligaments: Promise or Panacea?

    Science.gov (United States)

    Lubell, Adele

    1987-01-01

    The Food and Drug Administration has approved a prosthetic ligament for limited use in persons with damaged anterior cruciate ligaments (ACL). This article addresses ligament repair, ACL tears, current treatment, development of the Gore-Tex artificial ligament, other artificial ligaments in process, and arguments for and against their use.…

  10. Environmental and health impacts of artificial turf: a review.

    Science.gov (United States)

    Cheng, Hefa; Hu, Yuanan; Reinhard, Martin

    2014-02-18

    With significant water savings and low maintenance requirements, artificial turf is increasingly promoted as a replacement for natural grass on athletic fields and lawns. However, there remains the question of whether it is an environmentally friendly alternative to natural grass. The major concerns stem from the infill material that is typically derived from scrap tires. Tire rubber crumb contains a range of organic contaminants and heavy metals that can volatilize into the air and/or leach into the percolating rainwater, thereby posing a potential risk to the environment and human health. A limited number of studies have shown that the concentrations of volatile and semivolatile organic compounds in the air above artificial turf fields were typically not higher than the local background, while the concentrations of heavy metals and organic contaminants in the field drainages were generally below the respective regulatory limits. Health risk assessment studies suggested that users of artificial turf fields, even professional athletes, were not exposed to elevated risks. Preliminary life cycle assessment suggested that the environmental impacts of artificial turf fields were lower than equivalent grass fields. Areas that need further research to better understand and mitigate the potential negative environmental impacts of artificial turf are identified.

  11. Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties Correlação entre a variação diurna da pressão intraocular, amplitude de pulso e propriedades estruturais corneanas

    Directory of Open Access Journals (Sweden)

    Flávia Silva Villas-Bôas

    2009-06-01

    Full Text Available PURPOSE: The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, central corneal thickness, mean central corneal curvature and ocular pulse amplitude. METHODS: A total of 12 controls (24 eyes and 21 patients (38 eyes with open-angle glaucoma were recruited. Intraocular pressure measured by Goldmann applanation tonometry, dynamic contour tonometry and corneal compensated non-contact tonometry, ocular pulse amplitude, central corneal curvature and thickness, corneal hysteresis, and resistance factor were obtained at intervals of 2 hours, between 9 AM and 5 PM. RESULTS: Intraocular pressure fluctuated significantly throughout the day in controls and glaucoma individuals with all tonometers (POBJETIVO: Avaliar a flutuação das medidas da pressão intraocular obtidas pela tonometria de aplanação de Goldmann, tonometria de contorno dinâmico e pela tonometria de não-contato com compensação corneana durante o período ambulatorial, em participantes com glaucoma e saudáveis. Esse estudo também correlacionou as flutuações da pressão intraocular com as flutuações da histerese corneana, espessura corneana central, média da curvatura corneana central e amplitude de pulso ocular. MÉTODOS: Um total de 12 controles (24 olhos e 21 pacientes com glaucoma de ângulo aberto (38 olhos foram selecionados. A pressão intraocular medida pela tonometria de aplanação de Goldmann, tonometria de contorno dinâmico e tonometria de não-contato com compensação corneana, amplitude de pulso ocular, a curvatura central e espessura corneanas, a histerese corneana e o fator de resistência foram medidos em intervalos de 2 horas, entre 9

  12. Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report Implante invertido da lente intraocular Tecnis ZM900 multifocal: relato de caso

    Directory of Open Access Journals (Sweden)

    Wilson Takashi Hida

    2012-12-01

    Full Text Available A 51-year-old woman with age-related cataract had an uneventful phacoemulsification and a Tecnis ZM900 multifocal intraocular lens (IOL implantation in both eyes. During IOL implantation in the left eye, the optic was unintentionally reversed in the bag and left that way. The refraction surprise was not significant and six months postoperatively the corrected distance visual acuity in both eyes was 20/20 and neither complained of visual discomfort. In conclusion, we found that a reversed-optic Tecnis multifocal IOL in the present case resulted in good final visual acuity without significant differences in aberrations compared to the other eye, and a conservative management can be taken as a safe option.Paciente de 51 anos, sexo feminino, apresentando catarata foi submetida a cirurgia de facoemulsificação com implante de lente intraocular (LIO multifocal Tecnis ZM900 em ambos os olhos (AO. Durante a implantação da LIO no olho esquerdo, a lente foi inadvertidamente implantada invertida e deixada dessa maneira. Seis meses pós-operatório a surpresa refracional não se mostrou significativa e a acuidade visual corrigida era de 20/20 em AO, sem nenhuma queixa de desconforto visual. Em conclusão, no presente caso, o implante de uma LIO Tecnis multifocal invertida resultou em boa acuidade visual final e sem diferenças significativas na aberrometria em comparação ao olho contralateral, tendo sido possível conduzir o caso de maneira conservadora.

  13. Soft computing in artificial intelligence

    CERN Document Server

    Matson, Eric

    2014-01-01

    This book explores the concept of artificial intelligence based on knowledge-based algorithms. Given the current hardware and software technologies and artificial intelligence theories, we can think of how efficient to provide a solution, how best to implement a model and how successful to achieve it. This edition provides readers with the most recent progress and novel solutions in artificial intelligence. This book aims at presenting the research results and solutions of applications in relevance with artificial intelligence technologies. We propose to researchers and practitioners some methods to advance the intelligent systems and apply artificial intelligence to specific or general purpose. This book consists of 13 contributions that feature fuzzy (r, s)-minimal pre- and β-open sets, handling big coocurrence matrices, Xie-Beni-type fuzzy cluster validation, fuzzy c-regression models, combination of genetic algorithm and ant colony optimization, building expert system, fuzzy logic and neural network, ind...

  14. Beyond AI: Artificial Dreams Conference

    CERN Document Server

    Zackova, Eva; Kelemen, Jozef; Beyond Artificial Intelligence : The Disappearing Human-Machine Divide

    2015-01-01

    This book is an edited collection of chapters based on the papers presented at the conference “Beyond AI: Artificial Dreams” held in Pilsen in November 2012. The aim of the conference was to question deep-rooted ideas of artificial intelligence and cast critical reflection on methods standing at its foundations.  Artificial Dreams epitomize our controversial quest for non-biological intelligence, and therefore the contributors of this book tried to fully exploit such a controversy in their respective chapters, which resulted in an interdisciplinary dialogue between experts from engineering, natural sciences and humanities.   While pursuing the Artificial Dreams, it has become clear that it is still more and more difficult to draw a clear divide between human and machine. And therefore this book tries to portrait such an image of what lies beyond artificial intelligence: we can see the disappearing human-machine divide, a very important phenomenon of nowadays technological society, the phenomenon which i...

  15. What Is a Total Artificial Heart?

    Science.gov (United States)

    ... the NHLBI on Twitter. What Is a Total Artificial Heart? A total artificial heart (TAH) is a device ... outside power source. Normal Heart and CardioWest Total Artificial Heart Figure A shows the normal structure and location ...

  16. Iris Claw versus Scleral Fixation Intraocular Lens Implantation during Pars Plana Vitrectomy

    Directory of Open Access Journals (Sweden)

    Fereydoun Farrahi

    2012-01-01

    Full Text Available Purpose: To compare the outcomes of iris claw anterior chamber intraocular lens (ICACIOL with that of scleral fixation posterior chamber intraocular lens (SF-PCIOL implantation during pars plana vitrectomy (PPV as initial surgery to correct aphakia. Methods: Twelve patients with complicated cataract surgery or trauma who had suffered nucleus, whole crystalline lens or intraocular lens (IOL drop into the vitreous cavity, and undergone PPV with IC-ACIOL implantation over a period of one year were evaluated for the purpose of this study. Uncorrected visual acuity (UCVA, best corrected visual acuity (BCVA, central corneal thickness (CCT, spherical equivalent (SE refractive error, astigmatism and complications were recorded. The results were compared to outcomes of another group of 13 patients who had previously undergone PPV with SF-PCIOL implantation. Results: Mean improvement of UCVA was greater in IC-ACIOL eyes as compared to the SF-PCIOL group (-1.17±0.28 versus -0.89±0.21 logMAR, P=0.01, corresponding values for postoperative BCVA were 0.24±0.17 and 0.44±0.22 logMAR (P=0.041, respectively. Average postoperative SE was comparable in the IC-ACIOL and SFPCIOL groups at 0.6±1.03 and 0.56±1.23 diopters, respectively (P=0.290. However, 10 (83.3% IC-ACIOL eyes versus 6 (46.1% SF-PCIOL eyes had SE within 1 diopter of emmetropia (P=0.048. Mean postoperative increase in CCT was comaparble between the study groups (P=0.126. Conclusion: In the absence of sufficient capsular support, the use of an IC-ACIOL for correction of aphakia during PPV can be a good alternative and seems to entail better visual outcomes as compared to SF-PCIOL.

  17. Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses

    Directory of Open Access Journals (Sweden)

    Gibbons A

    2016-10-01

    Full Text Available Allister Gibbons, Tayyeba K Ali, Daniel P Waren, Kendall E Donaldson Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA Purpose: The purpose of this study was to assess the causes and possible solutions for patient dissatisfaction after the implantation of presbyopia-correcting intraocular lenses (IOLs. Methods: This study was a retrospective review of clinical records. All patients who were seen between January 2009 and December 2013 whose primary reason for consultation was dissatisfaction with visual performance after presbyopia-correcting IOL implantation were included in the study. A single treating physician, who determined the most probable cause of dissatisfaction, decided which interventions to pursue following the initial consultation. Results: Data from 74 eyes of 49 patients were analyzed. The most common cause for complaint was blurry or foggy vision both for distance and near (68%. Complaints were most frequently attributed to residual refractive error (57% and dry eye (35%. The most common interventions pursued were treatment of refractive error with glasses or contact lenses (46% and treatment for dry eye (24%. Corneal laser vision correction was done in 8% of eyes; 7% required an IOL exchange. After the interventions, 45% of patients had completed resolution of symptoms, 23% of patients were partially satisfied with the results, and 32% remained completely dissatisfied with the final results. Conclusion: The most identifiable causes of dissatisfaction after presbyopia-correcting IOL implantation are residual refractive error and dry eye. Most patients can be managed with conservative treatment, though a significant number of patients remained unsatisfied despite multiple measures. Keywords: intraocular lens, cataract, presbyopia, multifocal intraocular lens

  18. Toric markers-assisted implantation of the scleral-fixated intraocular lens

    Science.gov (United States)

    Song, Hu-Ping; Tian, Bing-Yu; Peng, Jing

    2016-01-01

    AIM To evaluate the efficacy of toric intraocular lens markers-assisted implantation of the scleral-fixated intraocular lens (SFIOL). METHODS From October 2010 to December 2013, all patients who had undergone secondary SFIOL implantation were assigned to group 1 and 2, in group 1 SFIOL was performed with the assist of radial keratotomy (RK)-marker, and in group 2 SFIOL was performed with the assisted of toric intraocular lens markers (T-and axis markers). Patients' demographic data and information on baseline preoperative visual acuity, indication for surgery and latest postoperative visual acuity were collected and analyzed. The haptic and optic positions were determined by ultrasound biomicroscopy. The optic tilt angle and decentration distance were measured. RESULTS The study evaluated 43 eyes of 43 patients ranging in age from 3 to 66y. Group 1 comprised 24 eyes (24 patients) and group 2, 19 eyes (19 patients). Uncorrected reoperative acuity was improved on all the eyes postoperatively. The improved postoperative acuity was significantly more in group 2 than that in group 1 (1.11±0.38 vs 0.82±0.45 logMAR; F=4.85, P=0.03). Ultrasonic biomicrograph examination showed that the rate of haptic asymmetry was significantly higher in group 1 (42%, 10/24) than that in group 2 (11%; 2/19) (Chi square=3.68, P=0.04). The mean tilted degree in group 1 was significantly higher than that in group 2 (P=0.04). Mean decentration distance in group 1 was greater than that in group 2 (P=0.03). CONCLUSION During SFIOL the toric markers help the surgeon identify the placement of fixation more precisely than that with the use of RK marker. PMID:27672593

  19. Evaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting

    Directory of Open Access Journals (Sweden)

    Gonen Baser

    2016-12-01

    Full Text Available Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP, body weights, as well as systolic and diastolic blood pressures (SBP, DBP of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m. in the Ramadan of 2014 and two weeks after it. The data were analyzed using paired Student’s t-test and Pearson correlation analysis. Results: As the results demonstrated, the mean diurnal IOP differences of IOP, SBP, DBP, and weight were 2.67±1.33 mmHg, 9.44±8.02 mmHg, 3.33±5.94 mmHg, and 0.90±0.46 kg during the fasting period, respectively. In addition, the mean diurnal IOP differences of IOP, SBP, DBP, and weight were -0.33±1.4 mmHg (P=0.001, 0.55±7.25mmHg (P=0.003, -3.33±5.94 mmHg (P=0.001, and 0.12±0.45 kg (P=0.001 during the control period, respectively. There was a moderate correlation between the diurnal IOP and SBP differences (r=0.517, P=0.028. Conclusion: Based on the findings of the current study, the total fluid volume might have a more dominant effect on IOP peaks than the sympathetic system activity. Furthermore, the SBP was found to correlate with the IOP.

  20. Effect of phacoemulsification combined with intraocular lens implantation on diabetic cataract treatment

    Institute of Scientific and Technical Information of China (English)

    Wei Gao; Chao Zhang; Li Jia; Hong Tang

    2016-01-01

    Objective:To observe the effect of phacoemulsification combined with intraocular lens implantation on inflammatory factors, oxidative stress reaction and the hemorheology in patients with diabetic cataract, for helping clinical treatment of patients with diabetic cataract. Methods: A total of 160 diabetic cataract patients in our hospital were selected and randomly divided into observation group and control group, each group were 80 cases, control group was treated with conventional therapy, observation group was treated with phacoemulsification combined with intraocular lens implantation based on conventional therapy, the changes of inflammatory factors, oxidative stress reaction and the hemorheology were detected before and after treatment.Results: The difference of inflammatory factors, oxidative stress reaction and the hemorheology in the two groups before treatment was not statistically significant (P>0.05). Inflammatory factors (IL-2, IL-6, hs-CRP and TNF-α), MDA in both groups after treatment significantly increased compared with that before treatment.; oxidative stress reaction parameters (CAT, SOD, GSH-Px), hemorheology parameters (WHV, WLV, PV) in both groups after treatment significantly decreased compared with that before treatment. Changes in PCV and FIB in two groups after treatment was not statistically significant compared with that before treatment (P>0.05). MDA, Inflammatory factors (IL-2, IL-6, , hs-CRP and TNF-α) and hemorheology parameters (WHV, WLV, PV) in observation group after treatment decreased more significantly than that in control group (P0.05). Conclusions:Phacoemulsification combined with intraocular lens implantation could improve inflammatory factors, oxidative stress reaction parameters and hemorheology parameters in diabetic cataract patients, and help clinical treatment of diabetic cataract patients.

  1. Treatment of cytomegalovirus retinitis with an intraocular sustained-release ganciclovir implant

    Directory of Open Access Journals (Sweden)

    Muccioli C.

    2000-01-01

    Full Text Available The objective of this prospective study was to evaluate the efficacy and complications of the use of an intraocular sustained-release ganciclovir implant for the treatment of active cytomegalovirus (CMV retinitis in AIDS patients. Thirty-nine eyes of 26 patients were submitted to ocular surgery. All patients underwent complete ocular examination before and after surgery. The surgical procedure was always done under local anesthesia using the same technique. The mean time for the surgical procedure was 20 min (range, 15 to 30 min. The average follow-up period was 3.7 months. Of all patient, only 4 presented recurrence of retinitis after 8, 8, 9 and 2 months, respectively. Three of them received a successful second implant. All 39 eyes of the 26 patients presented healing of retinitis as shown by clinical improvement evaluated by indirect binocular ophthalmoscopy and retinography. Retinitis healed within a period of 4 to 6 weeks in all patients, with clinical regression signs from the third week on. Six (15.4% eyes developed retinal detachment. None of the patients developed CMV retinitis in the contralateral eye. The intraocular implant proved to be effective in controlling the progression of retinitis for a period of up to 8 months even in patients for whom systemic therapy with either ganciclovir or foscarnet or both had failed. The intraocular sustained-release ganciclovir implant proved to be a safe new procedure for the treatment of CMV retinitis, avoiding the systemic side effects caused by the intravenous medications and improving the quality of life of the patients.

  2. Densiron® 68 as an intraocular tamponade for complex inferior retinal detachments

    Directory of Open Access Journals (Sweden)

    Hussain RN

    2011-05-01

    Full Text Available Rumana N Hussain, Somnath BanerjeeLeicester Royal Infirmary, Leicester, UKIntroduction: Densiron® 68 is a high-density liquid used to tamponade inferior retinal detachments. We present a case series of 12 patients treated with Densiron as an intraocular tamponade agent.Methods: A retrospective analysis of 12 eyes in 12 patients was carried out. The primary endpoint was anatomic reattachment of the retina following removal of Densiron oil.Results: All patients had inferior detachments; 33% had associated proliferative vitreoretinopathy (PVR. Densiron was utilized as a primary agent in five patients (42%; the remaining patients had prior unsuccessful surgery for retinal reattachment, including pars plana vitrectomy, cryotherapy, laser, encirclement, gas (C3F8 or C2F6, or silicone oil. Eleven patients (91% had successful reattachment of the retina at 3 months following removal of Densiron; one patient had extensive PVR, total retinal detachment, preretinal macula fibrosis, and chronic hypotony, and surgical intervention was unsuccessful. Six patients (50% had raised intraocular pressure (IOP, resolving in the majority of cases following Densiron removal; two patients had long-term raised IOP requiring topical or surgical therapy. Of the six phakic patients, 50% developed significant cataract in the operated eye. Of those with successful retinal reattachment, visual outcome was variable, with 36% patients gaining two to four lines on Snellen, 27% remaining objectively the same, and 36% losing one to two lines.Conclusion: The anatomic success rate is high (91% in patients requiring Densiron tamponade for inferior retinal detachments with or without evidence of PVR either as a primary or secondary intervention. A common complication is raised IOP; however, this most often resolves following removal of the oil.Keywords: intraocular tamponade, silicone oil, retinal detachment, retinal reattachments

  3. A time-delay calibrated method for cornea hysteresis and intraocular pressure measurement

    Science.gov (United States)

    Wang, Kuo-Jen; Tsai, Che-Liang; Wang, Wai; Hsu, Long; Hsu, Ken-Yuh

    2016-04-01

    The presence of cornea hysteresis (CH) in characterizing the intraocular pressure (IOP) of a human eye deteriorates the accuracy of IOP. To suppress CH, the pressure gauge of a tonometer must be located as close as possible to the cornea. However, this arrangement is unpractical because appropriate working distance to the cornea is required. In this paper, a time-delay calibrated (TDC) method is proposed to counteract the undesired effect of CH in characterizing the IOP. Employing this TDC method, the CH approaches to zero for most eyes measured.

  4. Estudio de la supervivencia de pacientes con Melanoma Uveal de Una Unidad Referencial de tumores Intraoculares

    OpenAIRE

    2013-01-01

    El melanoma uveal es el tumor intraocular primario maligno más frecuente en el adulto con supervivencia aproximada del 50% a los 10 años. El pronóstico está influenciado por características raciales y geográficas y son muy escasas las publicaciones de series del sur de Europa por lo que es posible que la supervivencia es estas poblaciones sea diferente. * Objetivos: Estudiar las características epidemiológicas, y la supervivencia de una serie de pacientes con melanoma uveal en una unidad de r...

  5. Pars plana cicatrization of sewn-in posterior chamber intraocular lens haptics.

    Science.gov (United States)

    McDermott, M L; Puklin, J E

    1997-03-01

    The authors describe the unexpected finding of cicatrization of posterior chamber lens haptics to the pars plana. This was found during removal of a secondary, transscleral sewn-in pseudophakos during a retinal reattachment procedure. Ophthalmic history and intraoperative photography revealed pars plana cicatrization of haptics. Despite removal of trans-scleral prolene fixation sutures and application of gentle traction, the posterior chamber lens haptics remained firmly adherent to pars plana retina. The haptics were amputated to prevent significant chorioretinal damage. The conventional belief that all sewn-in posterior chamber intraocular lenses cause little or no scarring response around the haptics may be unfounded.

  6. The Comprehensive Control of Astigmatism during and Following Intraocular Lens Implantation.

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    The operating corneoloscope and Terry operative keratometer were used respectively in 29 and 34 eyes during the intraocular lens implantation to measure the corneal astigmatism qualitatively or quantitatively,so that the tension of incision closure could be adjusted. The surgically induced astigmatism in qualitative group two weeks after the operation was 3. 5 ± 1. 70 D and that in quantitative group was 2. 56±1. 60 D. There were 55.17% and 38. 24% of the eyes with over 2. 00 D corneal astigmatism in qu...

  7. An investigation on dysphotopsia of a sigma-edged intraocular lens

    Institute of Scientific and Technical Information of China (English)

    Zhishan Gao; Meimei Kong; Xinhua Li; Lei Chen; Rihong Zhu

    2006-01-01

    @@ A sigma-edged design of intraocular lens (IOL) is proposed to minimize the reflected glare images associated with the edge. The optimal sigma inverse edge is investigated when pupil diameter is 5.0 mm by the established Escudero-Sanz's wide angle model. The non-sequential ray tracing program of Zemax-EE (Zemax Development Corp., San Diego, USA) is used to investigate the sigma edge of reducing the potential for edge glare phenomena. The results show that sigma-edged design can significantly reduce the reflected glare intensity on retina if the angle of its inverse edge is taken from 20 to 70 degrees.

  8. Intraocular lens confusions: a preventable "never event" - The Royal Victorian Eye and Ear Hospital protocol.

    Science.gov (United States)

    Zamir, Ehud; Beresova-Creese, Katarina; Miln, Linda

    2012-09-01

    Intraocular lens (IOL) confusions and errors are among the most common postoperative adverse events. Errors may occur at any stage from the decision to operate to the insertion of the IOL. The most common errors occur during IOL selection pre-operative preparation (anaesthesia given before recognition that the intended IOL is not available), or intraoperatively (wrong IOL implanted because of confusion in the operating room). We review the mechanisms of errors reported in the literature and describe the experience at The Royal Victorian Eye and Ear Hospital. We also describe the implementation of an error-detection protocol and provide qualitative data on its performance.

  9. Retropupillary iris-claw intraocular lens in ectopia lentis in Marfan syndrome

    Science.gov (United States)

    Faria, Mun Yueh; Ferreira, Nuno; Neto, Eliana

    2016-01-01

    Objective To report visual outcomes, complication rate, and safety of retropupillary iris-claw intraocular lens (ICIOL) in ectopia lentis in Marfan syndrome (MFS). Design Retrospective study. Methods Six eyes of three MFS patients with ectopia lentis underwent surgery for subluxation lens and retropupillary ICIOL implantation from October 2014 to October 2015 at the Department of Ophthalmology, Santa Maria Hospital in Lisbon, Portugal. Demographics, preoperative and postoperative best-corrected visual acuity (BCVA), and intraocular pressure were evaluated. Endothelium cell count was assessed using specular microscopy; anterior chamber depth was measured using Pentacam postoperatively; and intraocular lens position was viewed by ultrasound biomicroscopy. All patients were female; mean age was 20±14.264 years (range: 7–38 years). Results The average follow-up period was 6.66 months (range: 4–16 months). Preoperative BCVA was 0.568±0.149 logMAR units, and postoperative BCVA was 0.066±0.121 logMAR units. The mean BCVA gain was −0.502±0.221 on the logMAR scale. Postoperative average astigmatism and intraocular pressure were 1.292±0.697 mmHg (range: 0.5–2.25 mmHg) and 16 mmHg (range: 12–18 mmHg), respectively. The average endothelial cell density decreased from 3,121±178 cells/mm2 before surgery to 2,835±533 cells/mm2 after surgery (measured at last follow-up visit) and in the last follow-up, representing an average endothelial cell loss of 9.16%. Mean anterior chamber depth was 4.01 mm (±0.77 mm), as measured by Pentacam. No complications were found intra- or postoperatively in any of the six studied eyes. Conclusion Retropupillary ICIOL implantation is a safe and effective procedure in the treatment of aphakia in MFS eyes, without capsular support after surgery for ectopia lens. The six eyes that underwent lensectomy and retropupillary ICIOL implantation have had excellent visual outcomes with no complications so far. PMID:27382335

  10. Fungal endophthalmitis caused by Paecilomyces variotii, in an immunocompetent patient, following intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Anita K

    2010-01-01

    Full Text Available We report the case of a 70-year-old man who was admitted for anterior endophthalmitis following an intraocular lens implantation. He had developed a fluffy growth resembling a fungal mass on the iris of the right eye. The mass was removed and sent for fungal studies to our department. Direct microscopy revealed hyphae. Further studies helped identify the fungus to belong to genus Paecilomyces. This is a rare case of fungal endophthalmitis caused by Paecilomyces variotii in an immunocompetent person.

  11. Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Lucien A. M. van Philips

    2011-01-01

    Full Text Available Toxic anterior segment syndrome (TASS developed in four cases after uneventful implantation of a foldable iris-fixated phakic intraocular lens (pIOL. Two cases occurred sequentially in one patient. The TASS subsided without complications in all cases after intensive topical steroid treatment. A multitude of possible causes is considered for the occurrence of these TASS cases. From the sterilization and cleaning of surgical instruments to the possibility of endotoxines in ophthalmic viscosurgical devices (OVD. These rare cases should alert the surgeon to the possibility of TASS after pIOL implantation.

  12. Experimentally observe the effect of spherical aberration on diffractive intraocular lens using adaptive optics

    Science.gov (United States)

    Guo, Huanqing; DeLestrange, Elie

    2015-03-01

    We first investigated the similarity in optical quality of a batch of diffractive intraocular lenses (DIOLs), providing experimental evidence for one DIOL as representative of a batch. Using adaptive optics, we then evaluated one DIOL under different levels of Zernike spherical aberration (SA) by applying both a point spread function test and a psychophysical visual acuity test. We found that for small aperture size SA has the effect of shifting the through-focus curve of DIOL. Also, for a relatively large aperture size, it has different effects on the distant and near foci.

  13. Influence of ocular longitudinal chromatic aberration on the selection of aspheric intraocular lenses.

    Science.gov (United States)

    Hong, Xin; Choi, Myoung

    2010-12-06

    Polychromatic defocus could affect the optimal residual spherical aberration that could yield the best image quality for patients with intraocular lenses (IOLs). Modulation transfer functions (MTFs) were generated using a model that included polychromatic defocus. The maximum MTF volume occurred at + 0.05 μm of overall ocular spherical aberration. For 3 case studies, the optimal overall ocular spherical aberration was ~0.05 μm more positive with the contribution of polychromatic defocus than without it. Overall, the model indicated that image quality was usually best when IOLs allowed overall ocular spherical aberration that was slightly positive, rather than strongly positive, zero, or negative.

  14. Carbachol as miotic agent in intra-ocular lens implant surgery

    Directory of Open Access Journals (Sweden)

    Agarwal Jitendra

    1988-01-01

    Full Text Available The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens im-plant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:

  15. Twenty-four-hour intraocular pressure patterns in a symptomatic patient after ab interno trabeculotomy surgery

    Directory of Open Access Journals (Sweden)

    Mansouri K

    2014-11-01

    Full Text Available Kaweh Mansouri,1 Felipe A Medeiros,2 Robert N Weinreb2 1Glaucoma Sector, Department of Ophthalmology, Geneva University Hospitals, Geneva, Switzerland; 2Hamilton Glaucoma Center and Department of Ophthalmology, University of California, San Diego, La Jolla, CA, USA Abstract: We report the results of repeated ambulatory continuous 24-hour intraocular pressure (IOP monitoring with a contact lens sensor (CLS in a glaucoma patient with ocular pain after ab interno trabeculotomy (Trabectome™ surgery. Our findings show that a combined prostaglandin–pilocarpine treatment reduced nighttime IOP peaks and relieved the patient’s symptoms. Keywords: 24-hour, Trabectome contact lens sensor, prostaglandin–pilocarpine treatment

  16. Residual aniseikonia among patients fitted with one or two intraocular lenses (pseudophakic corrections)

    Science.gov (United States)

    Lakshminarayanan, V; Enoch, J M; Knowles, R A

    1993-02-01

    In the presence of one or two intraocular lenses (IOL's; pseudophakic corrections) or in the presence of naturally occurring or developmental anisometropia (due to a tumescent cataract) some induced or residual refractive aniseikonia is usually encountered. We wish to call this problem to the attention of the optometric practitioner. We provide a discussion of the resultant aniseikonia and simple rules of thumb for management of such patients with refractive aniseikonia. Aniseikonia in these patients may be less important than once had been suggested, but certainly it is more significant than it is currently being considered. Use of personal computers to calculate this aniseikonia makes appropriate correction relatively easy and readily applicable.

  17. Diseño y evaluación de perfiles de lentes intraoculares

    OpenAIRE

    2012-01-01

    El uso de lentes intraoculares (LIOs) monofocales, bifocales y acomodativas es una estrategia para restaurar el poder refractivo en los ojos tratados de las cataratas. Con el fin de comprender y mejorar la percepción visual de las escenas tridimensionales, abordamos el estudio de los diseños de las LIOs y evaluamos in vitro su desempeño. Inicialmente, proponemos dos diseños alternativos que compensan la falta de la acomodación, expandiendo la profundidad de foco del ojo. Los diseños se basan ...

  18. Innovative confocal laser method for exact dioptric power measurement of intraocular lens implants Invited Paper

    Institute of Scientific and Technical Information of China (English)

    Ilko K. Ilev; Robert W. Faaland; Do-Hyun Kim; Robert H. James; Don Calogero

    2008-01-01

    We present a novel confocal laser method (CLM) for precise testing of the dioptric power of both positive and negative intraocular lens (IOL) implants. The CLM principle is based on a simple fiber-optic confocal laser design including a single-mode fiber coupler that serves simultaneously as a point light source used for formation of a collimated Gaussian laser beam, and as a highly sensitive confocal point receiver. The CLM approach provides an accurate, repeatable, objective, and fast method for IOL dioptric power measurement over the range from 0 D to greater than =t=30 D under both dry and in-situ simulated conditions.

  19. Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Tendal, Britta

    2016-01-01

    TOPIC: We performed a systematic review and meta-analysis to evaluate the benefit and harms associated with implantation of toric intraocular lenses (IOLs) during cataract surgery. Outcomes were postoperative uncorrected distance visual acuity (UCDVA) and distance spectacle independence. Harms were...... literature search in the Embase, PubMed, and CENTRAL databases within the Cochrane Library. We included randomized clinical trials (RCTs) if they compared toric with non-toric IOL implantation (± relaxing incision) in patients with regular corneal astigmatism and age-related cataracts. We assessed the risk...

  20. The Clinical Analysis of Secondary Glaucoma Following Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    We present 14 patients with secondary gluacoma following the implantation of a posterior chamber intraocular lens (lOLs). All patients were u-nilateral gluacoma , which developed within 1 month following the IOL implantation in 10 cases, and from 1 to 3 years in 4 cases. The angle of anterior chamber was open in 8 patients, and close in 6 ones. Seven patients required treatment of antiglaucomatous medicine; 4 patients underwent laser indecto-my and 3 patients required antiglaucoma surgery. The results s...

  1. Unusual intraocular foreign bodies after an explosion: patient's hand bone fragments.

    Science.gov (United States)

    Sonmez, Murat; Duzgun, E; Yildirim, Y; Ayata, A; Unal, M H

    2016-04-01

    A 26-year-old Turkish Army soldier underwent full ophthalmoscopic examination after a penetrating ocular injury in the left eye due to the accidental explosion of a detonating fuse during handling. Visual acuity of the left eye was hand motion level. Funduscopy revealed foreign bodies suspended in the vitreous gel and accompanying vitreous haemorrhage. B-scan ultrasonography, CT of the orbits and microscopic examination of the intraocular foreign bodies (IOFBs) were performed prior to removal of bone fragments and pars plana vitrectomy. The IOFBs were fragments of the patients' bone tissue. Bone fragments from victim's body may cause IOFBs after an explosion in military personnel.

  2. 玻璃体切割硅油填塞术后眼压变化分析%Changes of intraocular pressure following silicone oil tamponade for vitrectomy

    Institute of Scientific and Technical Information of China (English)

    徐建敏; 张士胜; 张琼; 周颖明; 朱彩红; 葛健; 王玲

    2011-01-01

    目的 观察玻璃体切割硅油填塞术后的眼压变化,并探讨其可能原因.方法 对45例(45眼)玻璃体切割硅油填塞术后患者的临床资料进行回顾性分析,高眼压标准为术后眼压≥24 mmHg(1 mmHg=0.133 kPa).结果 22例(48.9%)患者出现高眼压,以术后早期(术后2周内)为多(17/22,77.3%).所有患者经降眼压药物治疗及调整激素用量或停用激素处理后,眼压均控制在正常范围.高眼压组与非高眼压组性别、年龄、病程、屈光度及硅油填充量比较差异均无统计学意义(P>0.∞).结论 高眼压是玻璃体切割硅油填充术后常见的并发症,术后眼内组织水肿、葡萄膜炎反应和频繁使用激素类滴眼液等可能是引起高眼压的主要原因.%Objective To observe the changes of intraocular pressure (IOP) following silicone oil tamponade for vitrectomy, and explore the possible causes. Methods The clinical data of 45 patients (45 eyes) undergoing silicone oil tamponade for vitrectomy were retrospectively analysed, and I0P elevation was defined as I0P of 24 mmHg ( 1 mmHg =0. 133 kPa) or higher. Results Postoperative IOP elevation occurred in 22 patients ( 48.9% ), especially in the early period after operation (2 weeks after operation) ( 17/22, 77.3% ). After using lOP-lowering drugs and adjusting or cessation of glucocorticoid eyedrops, the elevated lOP in all patients was controlled within normal limits. There was no significant difference in gender, age, course of disease, refractive diopters and volume of silicone oil tamponade between patients with and without elevated lOP ( P > 0.05 for all). Conclusion IOP elevation is a common complication following silicone oil tamponade for vitrectomy, and postoperative intraocular tissue edema, uveitis reaction and frequent use of glucocorticoid eyedrops may be the main causes.

  3. The heritability of glaucoma-related traits corneal hysteresis, central corneal thickness, intraocular pressure, and choroidal blood flow pulsatility.

    Directory of Open Access Journals (Sweden)

    Ellen E Freeman

    Full Text Available PURPOSE: The purpose of this work was to investigate the heritability of potential glaucoma endophenotypes. We estimated for the first time the heritability of the pulsatility of choroidal blood flow. We also sought to confirm the heritability of corneal hysteresis, central corneal thickness, and 3 ways of measuring intraocular pressure. METHODS: Measurements were performed on 96 first-degree relatives recruited from Maisonneuve-Rosemont Hospital in Montreal. Corneal hysteresis was determined using the Reichert Ocular Response Analyser. Central corneal thickness was measured with an ultrasound pachymeter. Three measures of intraocular pressure were obtained: Goldmann-correlated and corneal compensated intraocular pressure using the Ocular Response Analyser, and Pascal intraocular pressure using the Pascal Dynamic Contour Tonometer. The pulsatility of choroidal blood velocity and flow were measured in the sub-foveolar choroid using single-point laser Doppler flowmetry (Oculix. We estimated heritability using maximum-likelihood variance components methods implemented in the SOLAR software. RESULTS: No significant heritability was detected for the pulsatility of choroidal blood flow or velocity. The Goldman-correlated, corneal compensated, and Pascal measures of intraocular pressure measures were all significantly heritable at 0.94, 0.79, and 0.53 after age and sex adjustment (p = 0.0003, p = 0.0023, p = 0.0239. Central corneal thickness was significantly heritable at 0.68 (p = 0.0078. Corneal hysteresis was highly heritable but the estimate was at the upper boundary of 1.00 preventing us from giving a precise estimate. CONCLUSION: Corneal hysteresis, central corneal thickness, and intraocular pressure are all heritable and may be suitable as glaucoma endophenotypes. The pulsatility of choroidal blood flow and blood velocity were not significantly heritable in this sample.

  4. The artificial leaf.

    Science.gov (United States)

    Nocera, Daniel G

    2012-05-15

    To convert the energy of sunlight into chemical energy, the leaf splits water via the photosynthetic process to produce molecular oxygen and hydrogen, which is in a form of separated protons and electrons. The primary steps of natural photosynthesis involve the absorption of sunlight and its conversion into spatially separated electron-hole pairs. The holes of this wireless current are captured by the oxygen evolving complex (OEC) of photosystem II (PSII) to oxidize water to oxygen. The electrons and protons produced as a byproduct of the OEC reaction are captured by ferrodoxin of photosystem I. With the aid of ferrodoxin-NADP(+) reductase, they are used to produce hydrogen in the form of NADPH. For a synthetic material to realize the solar energy conversion function of the leaf, the light-absorbing material must capture a solar photon to generate a wireless current that is harnessed by catalysts, which drive the four electron/hole fuel-forming water-splitting reaction under benign conditions and under 1 sun (100 mW/cm(2)) illumination. This Account describes the construction of an artificial leaf comprising earth-abundant elements by interfacing a triple junction, amorphous silicon photovoltaic with hydrogen- and oxygen-evolving catalysts made from a ternary alloy (NiMoZn) and a cobalt-phosphate cluster (Co-OEC), respectively. The latter captures the structural and functional attributes of the PSII-OEC. Similar to the PSII-OEC, the Co-OEC self-assembles upon oxidation of an earth-abundant metal ion from 2+ to 3+, may operate in natural water at room temperature, and is self-healing. The Co-OEC also activates H(2)O by a proton-coupled electron transfer mechanism in which the Co-OEC is increased by four hole equivalents akin to the S-state pumping of the Kok cycle of PSII. X-ray absorption spectroscopy studies have established that the Co-OEC is a structural relative of Mn(3)CaO(4)-Mn cubane of the PSII-OEC, where Co replaces Mn and the cubane is extended in a

  5. [Research and development of artificial retina material].

    Science.gov (United States)

    Hu, Ning; Yang, Jun; Peng, Chenglin; Wang, Xing; Zhang, Sijie; Zhang, Ying; Zheng, Erxin

    2008-04-01

    The application of artificial retina was introduced. The principal characteristics of artificial retina material were reviewed in particular. Moreover, the recent research development and application prospect were discussed.

  6. Implante de lente intra-ocular dobrável acrílica em crianças

    OpenAIRE

    Jordão Jr.,Antonio; Romão,Erasmo

    2000-01-01

    Objetivos: Avaliar o uso de lentes intra-oculares dobráveis de acrílico na correção da afacia infantil. Métodos: Dez olhos de 10 pacientes com idades entre 3 e 9 anos portadores de catarata infantil foram operados e receberam o implante de lente intra-ocular dobrável de acrílico. Os pacientes foram acompanhados por um período que variou de 6 a 20 meses. Resultados: Após a medida da acuidade visual de todos no último retorno, encontramos uma melhora significativa em cinco pacientes. Em nenhum ...

  7. Influencia de las medidas queratométricas en el cálculo de la potencia de lentes intraoculares

    OpenAIRE

    Mateo Pérez, Verónica; Camps Sanchis, Vicente Jesús; Piñero Llorens, David Pablo; Fez Saiz, Dolores de

    2011-01-01

    PROPÓSITO: Determinar la influencia del error cometido en el cálculo de la potencia corneal queratométrica en el cálculo de la potencia de una lente intraocular. MÉTODO: Se analiza el error que se comete cuando se calcula la potencia de la lente intraocular utilizando la potencia corneal calculada por el método de Gauss ó por medio de un índice queratométrico (nk), y se analiza las dependencias con los radios de la cara anterior (r1c) y posterior (r2c) de la cornea, de la razón k, del modelo ...

  8. CATARACT SURGERY AND INTRAOCULAR LENS POWER CALCULATION IN A PATIENT WITH ANTERIOR MEGALOPHTHALMOS WITH NORMAL SIZED CRYSTALLINE LENS; CASE REPORT

    Directory of Open Access Journals (Sweden)

    Glišić Selimir

    2015-12-01

    Full Text Available Cataract surgery and intraocular lens power calculation is challenging in patients with anterior megalophthalmos and cataract, with postoperative refractive surprise frequently reported. Deep anterior chamber in these patients substantially influence effective lens position. To minimize possibility of refractive surprise, we used Haigis formula that takes into account anterior chamber depth in the lens power calculation for our patient. Cataract was managed by phakoemulsification with standard intraocular lens implanted in the capsular bag. Postoperatively, satisfying refractive result was achieved and refractive surprise was avoided.

  9. natural or artificial diets

    Directory of Open Access Journals (Sweden)

    A. O. Meyer-Willerer

    2005-01-01

    Full Text Available Se probaron alimentos artificiales y naturales con larva de camarón (Litopenaeus vannamei cultivados en diferentes recipientes. Estos fueron ocho frascos cónicos con 15L, ocho acuarios con 50L y como grupo control, seis tanques de fibra de vidrio con 1500L; todos con agua marina fresca y filtrada. La densidad inicial en todos los recipientes fue de 70 nauplios/L. Aquellos en frascos y acuarios recibieron ya sea dieta natural o artificial. El grupo control fue cultivado con dieta natural en los tanques grandes que utilizan los laboratorios para la producción masiva de postlarvas. El principal producto de excreción de larva de camarón es el ión amonio, que es tóxico cuando está presente en concentraciones elevadas. Se determinó diariamente con el método colorimétrico del indofenol. Los resultados muestran diferencias en la concentración del ión amonio y en la sobrevivencia de larvas entre las diferentes dietas y también entre los diferentes recipientes. En aquellos con volúmenes pequeños comparados con los grandes, se presentó mayor concentración de amonio (500 a 750µg/L, en aquellos con dietas naturales, debido a que este ión sirve de fertilizante a las algas adicionadas, necesitando efectuar recambios diarios de agua posteriores al noveno día de cultivo para mantener este ión a una concentración subletal. Se obtuvo una baja cosecha de postlarvas (menor a 15% con el alimento artificial larvario, debido a la presencia de protozoarios, alimentándose con el producto comercial precipitado en el fondo de los frascos o acuarios. Los acuarios con larvas alimentadas con dieta natural también mostraron concentraciones subletales de amonio al noveno día; sin embargo, la sobrevivencia fue cuatro veces mayor que con dietas artificiales. Los tanques control con dietas naturales presentaron tasas de sobrevivencia (70 ± 5% similares a la reportada por otros laboratorios.

  10. Artificial Neural Network Analysis System

    Science.gov (United States)

    2007-11-02

    Contract No. DASG60-00-M-0201 Purchase request no.: Foot in the Door-01 Title Name: Artificial Neural Network Analysis System Company: Atlantic... Artificial Neural Network Analysis System 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Powell, Bruce C 5d. PROJECT NUMBER 5e. TASK NUMBER...34) 27-02-2001 Report Type N/A Dates Covered (from... to) ("DD MON YYYY") 28-10-2000 27-02-2001 Title and Subtitle Artificial Neural Network Analysis

  11. Bioengineering of Artificial Lymphoid Organs.

    Science.gov (United States)

    Nosenko, M A; Drutskaya, M S; Moisenovich, M M; Nedospasov, S A

    2016-01-01

    This review addresses the issue of bioengineering of artificial lymphoid organs.Progress in this field may help to better understand the nature of the structure-function relations that exist in immune organs. Artifical lymphoid organs may also be advantageous in the therapy or correction of immunodefficiencies, autoimmune diseases, and cancer. The structural organization, development, and function of lymphoid tissue are analyzed with a focus on the role of intercellular contacts and on the cytokine signaling pathways regulating these processes. We describe various polymeric materials, as scaffolds, for artificial tissue engineering. Finally, published studies in which artificial lymphoid organs were generated are reviewed and possible future directions in the field are discussed.

  12. Artificial intelligence in medicine.

    Science.gov (United States)

    Hamet, Pavel; Tremblay, Johanne

    2017-04-01

    Artificial Intelligence (AI) is a general term that implies the use of a computer to model intelligent behavior with minimal human intervention. AI is generally accepted as having started with the invention of robots. The term derives from the Czech word robota, meaning biosynthetic machines used as forced labor. In this field, Leonardo Da Vinci's lasting heritage is today's burgeoning use of robotic-assisted surgery, named after him, for complex urologic and gynecologic procedures. Da Vinci's sketchbooks of robots helped set the stage for this innovation. AI, described as the science and engineering of making intelligent machines, was officially born in 1956. The term is applicable to a broad range of items in medicine such as robotics, medical diagnosis, medical statistics, and human biology-up to and including today's "omics". AI in medicine, which is the focus of this review, has two main branches: virtual and physical. The virtual branch includes informatics approaches from deep learning information management to control of health management systems, including electronic health records, and active guidance of physicians in their treatment decisions. The physical branch is best represented by robots used to assist the elderly patient or the attending surgeon. Also embodied in this branch are targeted nanorobots, a unique new drug delivery system. The societal and ethical complexities of these applications require further reflection, proof of their medical utility, economic value, and development of interdisciplinary strategies for their wider application.

  13. Artificial Immune Systems Tutorial

    CERN Document Server

    Aickelin, Uwe

    2008-01-01

    The biological immune system is a robust, complex, adaptive system that defends the body from foreign pathogens. It is able to categorize all cells (or molecules) within the body as self-cells or non-self cells. It does this with the help of a distributed task force that has the intelligence to take action from a local and also a global perspective using its network of chemical messengers for communication. There are two major branches of the immune system. The innate immune system is an unchanging mechanism that detects and destroys certain invading organisms, whilst the adaptive immune system responds to previously unknown foreign cells and builds a response to them that can remain in the body over a long period of time. This remarkable information processing biological system has caught the attention of computer science in recent years. A novel computational intelligence technique, inspired by immunology, has emerged, called Artificial Immune Systems. Several concepts from the immune have been extracted an...

  14. Artificial Immune Systems

    CERN Document Server

    Aickelin, Uwe

    2009-01-01

    The biological immune system is a robust, complex, adaptive system that defends the body from foreign pathogens. It is able to categorize all cells (or molecules) within the body as self-cells or non-self cells. It does this with the help of a distributed task force that has the intelligence to take action from a local and also a global perspective using its network of chemical messengers for communication. There are two major branches of the immune system. The innate immune system is an unchanging mechanism that detects and destroys certain invading organisms, whilst the adaptive immune system responds to previously unknown foreign cells and builds a response to them that can remain in the body over a long period of time. This remarkable information processing biological system has caught the attention of computer science in recent years. A novel computational intelligence technique, inspired by immunology, has emerged, called Artificial Immune Systems. Several concepts from the immune have been extracted an...

  15. Programmable artificial phototactic microswimmer

    Science.gov (United States)

    Dai, Baohu; Wang, Jizhuang; Xiong, Ze; Zhan, Xiaojun; Dai, Wei; Li, Chien-Cheng; Feng, Shien-Ping; Tang, Jinyao

    2016-12-01

    Phototaxis is commonly observed in motile photosynthetic microorganisms. For example, green algae are capable of swimming towards a light source (positive phototaxis) to receive more energy for photosynthesis, or away from a light source (negative phototaxis) to avoid radiation damage or to hide from predators. Recently, with the aim of applying nanoscale machinery to biomedical applications, various inorganic nanomotors based on different propulsion mechanisms have been demonstrated. The only method to control the direction of motion of these self-propelled micro/nanomotors is to incorporate a ferromagnetic material into their structure and use an external magnetic field for steering. Here, we show an artificial microswimmer that can sense and orient to the illumination direction of an external light source. Our microswimmer is a Janus nanotree containing a nanostructured photocathode and photoanode at opposite ends that release cations and anions, respectively, propelling the microswimmer by self-electrophoresis. Using chemical modifications, we can control the zeta potential of the photoanode and program the microswimmer to exhibit either positive or negative phototaxis. Finally, we show that a school of microswimmers mimics the collective phototactic behaviour of green algae in solution.

  16. Meta analysis on effect of caffeine on intraocular pressure in patients with glaucoma%咖啡因对青光眼患者眼压影响的Meta分析

    Institute of Scientific and Technical Information of China (English)

    熊海波; 易虹; 刘鑫; 代喻兵

    2015-01-01

    目的:评价咖啡因对青光眼患者眼压的影响。方法通过计算机检索 The Cochrane Library、PubMed、Embase、中国期刊全文数据库(CNKI)、中国科技期刊全文数据库(VIP)、万方数据库、中国生物医学文献数据库(CBM)从建库至2014年9月的相关文献,纳入口服咖啡因咖啡的随机对照试验(RCT),用RevMan5.2软件对咖啡因对青光眼患者眼压的影响进行M eta分析。结果共纳入3个研究,均为交叉试验。M eta分析结果显示,青光眼患者口服咖啡因咖啡后1 h (W M D1.58,95% C I 0.70~2.47)及1.5 h (W M D1.46,95% C I 1.20~1.72)眼压均有升高。结论咖啡因有升高青光眼患者眼压的作用。%Objective To evaluate the effect of caffeine on intraocular pressure in the patients with glaucoma . Methods The related literatures in the Cochrane Library ,PubMed ,Embase ,CNKI ,VIP ,Wan Fang database and CBM from the establishment to September 2014 were retrieved ,then the included randomized controlled trial(RCT) on the effect of caffeine on intraocular pressure in patients with glaucoma were performed the Meta analysis by using RevMan 5 .2 software .Results A total of 3 crossover trials were included .The results of Meta analysis showed that the intraocular pressure(IOP) was elevated at 1 h (WMD 1 .58 ,95% CI 0 .70 -2 .47) ,1 .5 h (WMD 1 .46 ,95% CI 1 .20-1 .72) after orally taking caffeine in glaucoma patients .Conclusion The caffeine has the effect for elevating IOP in the patients with glaucoma .

  17. Lærer-elev-relationer

    DEFF Research Database (Denmark)

    Laursen, Per Fibæk; Nielsen, Anne Maj

    2015-01-01

    I kapitlet belyser vi relationskompetence i forholdet mellem lærer og elever og hvordan læreren kan arbejde med forhold til elever og med sin opmærksomhed på relationsarbejdet. Afslutningsvis ser vi på hvordan lærere fortsat kan udvikle deres relationskompetence.......I kapitlet belyser vi relationskompetence i forholdet mellem lærer og elever og hvordan læreren kan arbejde med forhold til elever og med sin opmærksomhed på relationsarbejdet. Afslutningsvis ser vi på hvordan lærere fortsat kan udvikle deres relationskompetence....

  18. A Case of Intraocular Erosion and Intrusion by an Arruga Suture

    Directory of Open Access Journals (Sweden)

    Takakuni Kitagaki

    2016-03-01

    Full Text Available Purpose: To report a case of intraocular erosion and intrusion by an Arruga suture. Case Report: This study involved a 62-year-old male who had undergone scleral buckling surgery 40 or more years ago at another hospital for rhegmatogenous retinal detachment, as well as trabeculectomy 20 years ago for primary open-angle glaucoma, in his left eye at the same hospital. However, he recently became aware of blurred vision in that eye. Upon examination, iritis was observed in the anterior portion of his left eye, as well as a great number of pigment cell keratoprecipitates on the posterior surface of the cornea. In the ocular fundus, extensive atrophy of the retinal pigment epithelium and partial hyperpigmentation was observed, accompanied by subretinal strands, yet the retina remained attached. Around the entire peripheral area of the retina we observed a ring-shaped protrusion, but we also saw a shiny, filamentous material in the vitreous cavity that penetrated the sclera and choroid, completely extending from the 4- to 8-o'clock position of the scleral buckle protrusion. To treat the iritis in the patient's left eye, we began to administrate low-concentration steroid eye drops, after which the inflammation disappeared. Conclusion: In this study, we experienced a case of intraocular erosion and intrusion by an Arruga suture, and opted to treat the patient with steroid eye drops and conservative follow-up observations unless retinal redetachment and/or vitreous hemorrhage occurs.

  19. A Case of Intraocular Erosion and Intrusion by an Arruga Suture

    Science.gov (United States)

    Kitagaki, Takakuni; Morishita, Seita; Kohmoto, Ryohsuke; Fukumoto, Masanori; Suzuki, Hiroyuki; Sato, Takaki; Kobayashi, Takatoshi; Kida, Teruyo; Nakajima, Masayuki; Ikeda, Tsunehiko

    2016-01-01

    Purpose To report a case of intraocular erosion and intrusion by an Arruga suture. Case Report This study involved a 62-year-old male who had undergone scleral buckling surgery 40 or more years ago at another hospital for rhegmatogenous retinal detachment, as well as trabeculectomy 20 years ago for primary open-angle glaucoma, in his left eye at the same hospital. However, he recently became aware of blurred vision in that eye. Upon examination, iritis was observed in the anterior portion of his left eye, as well as a great number of pigment cell keratoprecipitates on the posterior surface of the cornea. In the ocular fundus, extensive atrophy of the retinal pigment epithelium and partial hyperpigmentation was observed, accompanied by subretinal strands, yet the retina remained attached. Around the entire peripheral area of the retina we observed a ring-shaped protrusion, but we also saw a shiny, filamentous material in the vitreous cavity that penetrated the sclera and choroid, completely extending from the 4- to 8-o'clock position of the scleral buckle protrusion. To treat the iritis in the patient's left eye, we began to administrate low-concentration steroid eye drops, after which the inflammation disappeared. Conclusion In this study, we experienced a case of intraocular erosion and intrusion by an Arruga suture, and opted to treat the patient with steroid eye drops and conservative follow-up observations unless retinal redetachment and/or vitreous hemorrhage occurs. PMID:27099609

  20. Dosimetry and treatment planning of Occu-Prosta I-125 seeds for intraocular lesions

    Directory of Open Access Journals (Sweden)

    Chaudhari Suresh

    2008-01-01

    Full Text Available Intraocular malignant lesions are frequently encountered in clinical practice. Plaque brachytherapy represents an effective means of treatment for intraocular lesions. Recently Radiopharmaceutical Division, BARC, Mumbai, has indigenously fabricated reasonable-cost I-125 sources. Here we are presenting the preliminary experience of dosimetry of sources, configuration of treatment planning system (TPS and quality assurance (QA for eye plaque therapy with Occu-Prosta I-125 seeds, treated in our hospital, for a patient with ocular lesions. I-125 seeds were calibrated using well-type chamber. BrachyVision TPS was configured with Monte Carlo computed radial dose functions and anisotropy functions for I-125 sources. Dose calculated by TPS at different points in central axis and off axis was compared with manually calculated dose. Eye plaque was fabricated of 17 karat pure gold, locally. The seeds were arranged in an outer ring near the edge of the plaque and in concentric rings throughout the plaque. The sources were manually digitized on the TPS, and dose distribution was calculated in three dimensions. Measured activity using cross-calibrated well-type chamber was within ±10% of the activity specified by the supplier. Difference in TPS-calculated dose and manually calculated dose was within 5%. Treatment time calculated by TPS was in concordance with published data for similar plaque arrangement.