WorldWideScience

Sample records for artificial hips

  1. Wear prediction of ceramic-on-ceramic hip artificial joints

    OpenAIRE

    Askari, E; Flores, Paulo; Dabirrahmani, D.; Appleyard, R.

    2015-01-01

    Wear can influence the lifetime and performance of implants and has been found to be a key factor in primary failure of artificial hip joints. The present study aims to present a spatial multibody dynamic model to predict wear in ceramic-on-ceramic hip implants. The problem was formulated by developing a spatial multibody dynamic model of a hip prosthesis taking three-dimensional physiological loading and motion of the human body into account. Then, the Archard wear model was inte...

  2. Magnetic suspension hip joint: an ideal design of an artificial joint

    Institute of Scientific and Technical Information of China (English)

    DAI Min; NIE Tao

    2010-01-01

    Background Artificial joints present certain problems such as osteal absorption and lysis induced by wear debris which leads to loosening of the prosthesis over a period of time. Here we propose a design of an artificial magnetic suspension joint that was prepared by integrating the medical theories of modern material science, magnetism, and medical physics.Methods According to clinical characteristic of biological and mechanical for hip joint, we designed the appearance and dimensions of magnetic suspension joint and placed neodymium-iron-boron permanent magnets in the prosthesis.As the same time, we performed mechanical and biological experiments using artificial magnetic suspension hip joints models.Results By simulated the human hip structure and the external load, we discovered the artificial magnetic suspension hip joints models had much lesser amount and size of wear debris than the ceramic/ceramic artificial hip joint prosthesis in friction wear tests. The force between the artificial joints with magnetic materials that we have calculated is feasible for application of artificial joint. The design of artificial magnetic suspension hip joints models was plausible technically and safe biologically.Conclusion Artificial magnetic suspension hip joints may effectively reduce the incidence of the loosening of prosthesis over a period of time.

  3. Tantalum as a buffer layer in diamond-like carbon coated artificial hip joints.

    Science.gov (United States)

    Kiuru, Mirjami; Alakoski, Esa; Tiainen, Veli-Matti; Lappalainen, Reijo; Anttila, Asko

    2003-07-15

    The acid resistance of tantalum coated and uncoated human hip joint prostheses was studied with commercial CrCoMo acetabular cups. The samples were exposed to 10% HCl solution and the quantities of dissolved Cr, Co, and Mo were measured with proton-induced X-ray emission (PIXE). The absolute quantities were obtained with the use of Cr and Se solution standards. Tantalum coatings (thicknesses 4-6 microm) were prepared in vacuum with magnetron sputtering. Tantalum coating decreased the corrosion rate by a factor of 10(6). As a spinoff from recent wear tests on artificial hip joints it was shown that tantalum has excellent mechanical properties as an intermediate layer of diamond-like carbon (DLC) coatings. When tantalum was tested together with DLC on three metal-on-metal hip joint pairs in a hip simulator, no observable defects occurred during 15 million walking cycles with a periodic 50-300-kg load (Paul curve). PMID:12808604

  4. Preparation for femur prosthesis of ceramic-metal combination artificial hip joint

    Institute of Scientific and Technical Information of China (English)

    王欣宇; 李世普; 陈晓明; 贺建华

    2002-01-01

    Al2O3 material was synthesized by using high purity alumina micro-powder and Mg-Zr-Y composite additives at temperature of 1600℃, which had good mechanics property of 416MPa bending strength and 5.46MPa*m1/2 fracture toughness. Femur head prosthesis of hip joint was prepared by using this material; Ti alloy femur handle was sprayed bioactive hydroxyapatite (HA) by plasma on surface, which improves the chemistry stability and biocompatibility of Ti alloy; ceramic-metal combination artificial hip joint femur prosthesis was made by combining Al2O3 femur head with Ti alloy femur handle, so the manufacturing process is improved and the property and application flexibility are advanced.

  5. Diamond-like carbon coatings deposited by vacuum arc in artificial hip joints

    OpenAIRE

    Ren, Ying

    2014-01-01

         For biomedical application in the field of artificial hip joints diamond-like carbon (DLC) coatings have been widely studied due to their excellent mechanical, tribological and biological properties. At present the lifetime of such joints is just about 15 years and some (10%) of patients require second replacementent. In consequence, it is currently an urgent need to extend the life expectancy especially for younger patients under 50 years old. As is well known, the wear particles as the...

  6. Hard-on-hard lubrication in the artificial hip under dynamic loading conditions.

    Directory of Open Access Journals (Sweden)

    Robert Sonntag

    Full Text Available The tribological performance of an artificial hip joint has a particularly strong influence on its success. The principle causes for failure are adverse short- and long-term reactions to wear debris and high frictional torque in the case of poor lubrication that may cause loosening of the implant. Therefore, using experimental and theoretical approaches models have been developed to evaluate lubrication under standardized conditions. A steady-state numerical model has been extended with dynamic experimental data for hard-on-hard bearings used in total hip replacements to verify the tribological relevance of the ISO 14242-1 gait cycle in comparison to experimental data from the Orthoload database and instrumented gait analysis for three additional loading conditions: normal walking, climbing stairs and descending stairs. Ceramic-on-ceramic bearing partners show superior lubrication potential compared to hard-on-hard bearings that work with at least one articulating metal component. Lubrication regimes during the investigated activities are shown to strongly depend on the kinematics and loading conditions. The outcome from the ISO gait is not fully confirmed by the normal walking data and more challenging conditions show evidence of inferior lubrication. These findings may help to explain the differences between the in vitro predictions using the ISO gait cycle and the clinical outcome of some hard-on-hard bearings, e.g., using metal-on-metal.

  7. Wear Debris Characterization and Corresponding Biological Response: Artificial Hip and Knee Joints

    Directory of Open Access Journals (Sweden)

    Md J. Nine

    2014-02-01

    Full Text Available Wear debris, of deferent sizes, shapes and quantities, generated in artificial hip and knees is largely confined to the bone and joint interface. This debris interacts with periprosthetic tissue and may cause aseptic loosening. The purpose of this review is to summarize and collate findings of the recent demonstrations on debris characterization and their biological response that influences the occurrence in implant migration. A systematic review of peer-reviewed literature is performed, based on inclusion and exclusion criteria addressing mainly debris isolation, characterization, and biologic responses. Results show that debris characterization largely depends on their appropriate and accurate isolation protocol. The particles are found to be non-uniform in size and non-homogeneously distributed into the periprosthetic tissues. In addition, the sizes, shapes, and volumes of the particles are influenced by the types of joints, bearing geometry, material combination, and lubricant. Phagocytosis of wear debris is size dependent; high doses of submicron-sized particles induce significant level of secretion of bone resorbing factors. However, articles on wear debris from engineered surfaces (patterned and coated are lacking. The findings suggest considering debris morphology as an important parameter to evaluate joint simulator and newly developed implant materials.

  8. Vibration transfer in the ball-stem contact interface of artificial hips.

    Science.gov (United States)

    Hothan, Arne; Lewerenz, Kathrin; Weiss, Cornelius; Hoffmann, Norbert; Morlock, Michael; Huber, Gerd

    2013-10-01

    Audible squeaking has put the reputation of ceramic bearings for total hip replacements into question. Inter-articular friction induces vibrations in the ceramic head which are transferred through the head-taper interface to the femoral stem. If excited to sufficient amplitudes, squeaking can be emitted by the stem. Hence, the damping and amplification properties of this interface have a crucial influence on stem vibrations. The aim of this study was to determine the vibration transfer behavior between the head and the taper of a femoral stem and its dependence on the assembly force, in order to assess its influence on the development of audible squeaking. A ceramic head was assembled on a titanium femoral stem taper with high and low forces. Frequency response functions characterizing the head-stem interface were determined experimentally. The interface demonstrated negligible influence on vibration transfer in the squeaking frequency range (1-5 kHz). However its damping effect in lower and higher frequency ranges was significant and some areas of amplification were also found. Although squeaking vibration was not influenced by the particular interface studied, the method established can be utilized to trace taper designs with dynamic properties that decrease the susceptibility to squeaking. PMID:23707143

  9. In vitro assessment of Function Graded (FG artificial Hip joint stem in terms of bone/cement stresses: 3D Finite Element (FE study

    Directory of Open Access Journals (Sweden)

    Al-Jassir Fawzi F

    2013-01-01

    Full Text Available Abstract Background Stress shielding in the cemented hip prosthesis occurs due to the mismatching in the mechanical properties of metallic stem and bone. This mismatching in properties is considered as one of the main reasons for implant loosening. Therefore, a new stem material in orthopedic surgery is still required. In the present study, 3D finite element modeling is used for evaluating the artificial hip joint stem that is made of Function Graded (FG material in terms of joint stress distributions and stem length. Method 3D finite element models of different stems made of two types of FG materials and traditional stems made of Cobalt Chromium alloy (CoCrMo and Titanium alloy (Ti were developed using the ANSYS Code. The effects on the total artificial hip joint stresses (Shear stress and Von Mises stresses at bone cement, Von Mises stresses at bone and stem due to using the proposed FG materials stems were investigated. The effects on the total artificial hip joint system stresses due to using different stem lengths were investigated. Results Using FG stem (with low stiffness at stem distal end and high stiffness at its proximal end resulted in a significant reduction in shear stress at the bone cement/stem interface. Also, the Von Mises stresses at the bone cement and stem decrease significantly when using FG material instead of CoCrMo and Ti alloy. The stresses’ distribution along the bone cement length when using FG material was found to be more uniform along the whole bone cement compared with other stem materials. These more uniform stresses will help in the reduction of the artificial hip joint loosening rate and improve its short and long term performance. Conclusion FE results showed that using FG stem increases the resultant stresses at the femur bone (reduces stress shielding compared to metallic stem. The results showed that the stem length has significant effects on the resultant shear and Von Mises stresses at bone, stem and

  10. Design of artificial hip joint prosthesis and analysis of interface stress%人工髋关节假体的设计及界面应力分析

    Institute of Scientific and Technical Information of China (English)

    安明勋

    2012-01-01

    背景:骨正确选择与宿主相容性良好的假体是保证全髋关节置换成功的重要因素,与置换后人工关节的生物力学性能和使用寿命有着密切的关系.目的:总结人工髋关节假体的研究进展,分析人工髋关节假体设计与界面力学对假体植入后生物相容的影响.方法:采用电子检索的方式在万方数据库中检索2000-01/2011-12有关髋关节假体材料及人工髋关节置换先关的研究,关键词为"髋关节、假体、置换、生物力学".排除重复研究、普通综述或Meta分析类文章.结果与结论:共纳入34篇文献进行评价.全髋关节置换后人工关节的生物力学性能与使用寿命有着密切的关系,假体受力可以分解为正应力和剪切应力两部分,正应力有益于假体的固定和力的传递,而剪切力会导致假体松动.假体周围骨质及骨量的变化,假体松动、脱位,假体周围骨折,材料磨损及假体周围感染是髋关节置换后影响中远期效果的常见并发症.目前还缺乏生物相容性好、生物力学相容性好的理想假体,人工髋关节设计、制造工艺、假体材料的耐磨性与界面应力等生物力学性能均有待于进一步提高,从而更好地适应宿主.%BACKGROUND: A correct prosthesis with good compatibility to the host is the key for the success of total hip arthroplasty, and it relates to the biomechanical properties and service life of artificial joint after replacement. OBJECTIVE: To summarize the research progress about artificial hip joint prosthesis and to analyze the effect of artificial hip joint prosthesis design and interface stress on the compatibility of clinically used metal hip joint. METHODS: An electronic retrieve was performed in Wanfang database from January 2000 to December 2011 for articles regarding the hip prosthesis materials and artificial hip replacement, key words were "hip joint, prosthesis, replacement, biomechanics" in Chinese. The

  11. Novel artificial hip joint: A layer of alumina on Ti-6Al-4V alloy formed by micro-arc oxidation.

    Science.gov (United States)

    Khanna, Rohit; Kokubo, Tadashi; Matsushita, Tomiharu; Nomura, Yuuji; Nose, Norihiro; Oomori, Yoshiyuki; Yoshida, Takuya; Wakita, Koichi; Takadama, Hiroaki

    2015-10-01

    In many hip replacement surgeries, monolithic alumina is used as a femoral head due to its high wear resistance. However, it is liable to fracture under load bearing operations in artificial joints. We propose a promising way to overcome this limitation by forming a dense alumina layer onto a relatively tough substrate such as Ti-6Al-4V alloy to obtain high wear resistance on a material that can sustain relatively high toughness. For this purpose, Al metal powders were deposited onto Ti-6Al-4V alloy by cold spraying in N2 atmosphere. Interfacial adhesion between Al and the Ti alloy was improved by the formation of a reaction layer of Al3Ti between them by heating at 640 °C for 1h in air. Subsequently, micro-arc oxidation treatment was performed to oxidize Al. The oxidized layer was composed of an outer porous layer of γ-alumina and inner-most dense layer of α-alumina. The α-alumina layer was almost fully densified and exhibited high Vickers hardness almost equal to that of alumina ceramics used as the femoral head. Thus, the newly developed dense alumina/Ti alloy can be potentially used to produce the reliable bearing surfaces of artificial hip joint. PMID:26117770

  12. Hip joint replacement

    Science.gov (United States)

    ... may have problems with infection, loosening, or even dislocation of the new hip joint. Over time the artificial ... Professor, Chief, Sports Medicine and Shoulder Service, UCSF Department of Orthopaedic Surgery, San Francisco, ...

  13. 髋关节强直人工关节置换术治疗分析%Experience of hip artificial joint replacement in the treatment of ankylosis of hip joint

    Institute of Scientific and Technical Information of China (English)

    冯国英; 王心宽; 张辉; 刘铁军

    2014-01-01

    Objective To investigate the clinical curative effect and the technique of hip artificial joint replacement in the treatment of ankylosis of hip joint.Methods A retrospective data of 19 patients with hip joint ankylosis operated by artificial joint replacement was reviewed between July 2010 and June 2013 in our hospital.The hipfusion due to ankylosing spondylitis was in 15 cases; congenital acetabular dysplasia and osteoarthritis were in 3 cases; ischemic necrosis of femoral head was in 1 case.The history of all the cases was 5-40 years in which 15 cases of hip joint was complete rigidity and no activity with hip 10 °-45 ° of adduction and flexion.The preoperative,intraoperative and postoperative data were summarized.Results Totally 19 cases were all followed up and the follow-up time was 0.5-3.5 years.All the patients had no complications after operation,such as nerve,vascular injury,acute pulmonary embolism,acute renal and heart failure,pulmonary infection and deep vein thrombosis.During the follow-up period,all the patients had no dislocation,loosening prosthesis and delayed infection.The postoperative activity of hip joint was significantly improved after operation.There were 3 cases (15.8%) of heterotopic ossification.Conclusions Artificial joint replacement is an ideal method in the treatment of hip joint ankylosis,which can significantly improve the joint function and the quality of life.Intraoperative technology directly affects the effect after operation.The lateral approach of hip joint has a lot of advantages and can effectively prevent the dislocation after artificial joint replacement.%目的 探讨髋关节强直人工关节置换手术的临床疗效和技术要点.方法 回顾性分析自2010年7月至2013年6月在北京市通州区中西医结合医院住院的19例髋关节强直患者经过人工关节置换手术后的临床资料.其中强直性脊柱炎髋关节融合15例,先天性髋臼发育不良伴骨性关节炎3

  14. Fabrication of dense α-alumina layer on Ti-6Al-4V alloy hybrid for bearing surfaces of artificial hip joint.

    Science.gov (United States)

    Khanna, Rohit; Kokubo, Tadashi; Matsushita, Tomiharu; Takadama, Hiroaki

    2016-12-01

    Recent advances in hip replacements are focused towards producing reliable bearing surfaces to enhance their longevity. In this perspective, progressive attempts have been made to improve the wear resistance of polyethylene to eliminate osteolysis and mechanical reliability of brittle alumina ceramics, but in vain. It is proposed that both high wear resistance and mechanical reliability can be retained if a thin layer of dense alumina is formed onto high toughness Ti-6Al-4V alloy. For this purpose, we devised a unique methodology in which a layer of Al metal was deposited onto the Ti alloy substrate by cold spraying (CS), followed by a heat treatment to form Al3Ti reaction layer at their interface to improve adhesion and subsequent micro-arc oxidation (MAO) treatment to transform Al to alumina layer. An optimal MAO treatment of cold sprayed Al formed an adherent and dense α-alumina layer with high Vickers hardness matching with that of sintered alumina used as a femoral head. Structure-phase-property relationships in dense α-alumina layer have been revealed and discussed in the light of our research findings. The designed alumina/Ti alloy hybrid might be a potential candidate for reliable bearing surfaces of artificial hip joint. PMID:27612821

  15. Hip Replacement

    Science.gov (United States)

    Hip replacement is surgery for people with severe hip damage. The most common cause of damage is ... therapy, pain medicines, and exercise haven't helped, hip replacement surgery might be an option for you. ...

  16. Hip instability.

    Science.gov (United States)

    Smith, Matthew V; Sekiya, Jon K

    2010-06-01

    Hip instability is becoming a more commonly recognized source of pain and disability in patients. Traumatic causes of hip instability are often clear. Appropriate treatment includes immediate reduction, early surgery for acetabular rim fractures greater than 25% or incarcerated fragments in the joint, and close follow-up to monitor for avascular necrosis. Late surgical intervention may be necessary for residual symptomatic hip instability. Atraumatic causes of hip instability include repetitive external rotation with axial loading, generalized ligamentous laxity, and collagen disorders like Ehlers-Danlos. Symptoms caused by atraumatic hip instability often have an insidious onset. Patients may have a wide array of hip symptoms while demonstrating only subtle findings suggestive of capsular laxity. Traction views of the affected hip can be helpful in diagnosing hip instability. Open and arthroscopic techniques can be used to treat capsular laxity. We describe an arthroscopic anterior hip capsular plication using a suture technique. PMID:20473129

  17. Hip Ultrasound

    Science.gov (United States)

    ... Infant ultrasound can be used to check the hips for developmental dysplasia of the hip (DDH), which in infants can range from a shallow cup (bony acetabular dysplasia), to complete dislocation with the ball of the ...

  18. Hip Revision

    Medline Plus

    Full Text Available Hip Revision Featuring the ZMR® Hip System Tapered Distal Stem Zimmer, Inc. Winfield, Illinois September 3, 2009 Welcome to this OR Live webcast presentation, brought to you by Zimmer. ...

  19. Hip Revision

    Medline Plus

    Full Text Available ... Revision Featuring the ZMR® Hip System Tapered Distal Stem Zimmer, Inc. Winfield, Illinois September 3, 2009 Welcome ... a hybrid hip arthroplasty with a cemented femoral stem and an acetabular shell. You can see the ...

  20. Biological characteristics and clinical application of artificial hip joint weight-bearing surface materials%人工髋关节负重面材料的生物特性及其临床应用

    Institute of Scientific and Technical Information of China (English)

    唐焜

    2012-01-01

    背景:人工髋关节假体材料对髋关节置换的成功率及对患者治愈率起到决定性作用.目的:评价不同组合方式髋关节负重面材料的性能及置入体内与机体的生物相容性.方法:以"全髋关节置换,人工髋关节,金属,陶瓷,聚乙烯,生物相容性,临床应用;total hip replacement,Artificialhip,prosthetic materials,Biocompatibility,clinical application"为关键词,应用计算机检索2001-01/2011-12 万方数据库、PubMed 数据库有关人工髋关节负重面生物材料与宿主生物相容性的文章.结果与结论:金属-超高分子量聚乙烯组合是目前常用的组合,也是衡量其他组合的金标准,但其磨损颗粒引起周围组织反应导致骨溶解和无菌性假体松动;金属-高交联聚乙烯、金属-金属、陶瓷-陶瓷和陶瓷-聚乙烯组合均在一定程度上减少了磨损,但金属离子毒性、陶瓷脆性、造价高等仍然是需要解决的问题.理想的负重面材料应具有良好生物相容、耐蚀性、耐磨性、耐疲劳性、强韧性好等特点,目前人工髋关节负重面组合材料各有优缺点.因此,临床医师针对不同的患者,采取个体化治疗原则,综合患者病情和经济状况等多方面因素,选择合适假体组合类型,以期达到最佳临床疗效.%BACKGROUND: Artificial hip prosthesis materials play a decisive role in the success rates of hip replacement and the recovery rate for patientsOBJECTIVE: To evaluate the properties of hip joint weight-bearing surface materials with different combinations, as well as the biocompatibihty of the materials and the host after implanted in vivoMETHODS: The keyword of "total hip replacement, artificial hip joint, metal, ceramic, polyethylene, biocompatibihty, clinical application" in Chinese and "total hip replacement, artificial hip, prosthetic materials, biocompatibihty, clinical application" in English were used to retrieve the articles published from January 2001 to

  1. 数字技术在人工全髋关节置换术中的应用研究%Research on application of digital technology in artificial total hip replacement

    Institute of Scientific and Technical Information of China (English)

    李世芳; 周道政; 张韶辉; 刘丽芳

    2012-01-01

    Objective To explore the digital technology applied in clinical artificial total hip replacement and provide a new way to choose suitable artificial hip joint prosthesis. Methods Six adult lesions hips, No. 42-56 acetabular prosthesis and No. 01-04 titanium femoral stem (Rectangle HA porous) were scanned by three-dimensional CT. The data were processed by the Mimics software. Three dimensional models of hip and prosthesis were established. These measurement results were analyzed with SPSS 17.0. The appropriate prosthesis was selected according to the result of the digital model. The operation was performed with preoperative choice of prosthesis. Harris's method was used to evaluate the curative effect 6 months after operation. The difference was compared with others statistically. Results The measurement results of 6 cases of 3D model data showed that acetabular anteversion, abduction angle and height, sex, age, side of the other factors had no significant differences. Femoral neck anteversion, neck shaft angle and the side of the gender, age and height had no significant difference. Conclusion The digital technology can be used as a guide in selecting more matching total hip prosthesis for patients, improving total hip arthroplasty short-term effect and providing a new approach for the total hip prosthesis selection before operation.%目的 探索把数字技术应用于人工全髋关节置换术,为临床选择更适配的人工全髋关节假体提供新的方法.方法 6例成人病变的髋关节和42-56号的髋臼假体和01-04号钛合金股骨柄(矩形,HA微孔)假体连续CT扫描,将CT扫描数据经Mimics软件处理,3D计算建立髋关节和假体的数字模型.将数据输入SPSS 17.0进行统计学分析.根据术前选择的假体施行手术,术后6个月根据Harris评分进行评价,并与同期6例行传统人工全髋关节置换术患者髋关节Harris 评分进行统计学比较.结果 6例骨盆三维模型数据测量结果分析:髋

  2. Analysis of the Effect of Artificial Hip Replacement in the Treatment of Acetabular Defect%髋臼缺损畸形的人工髋关节置换手术疗效分析

    Institute of Scientific and Technical Information of China (English)

    武豪杰

    2015-01-01

    Objective To study the acetabulum defect deformity treatment methods of artificial total hip replacement. Methods 30 cases of acetabular defects were selected in our hospital, including 13 cases of acetabulum hypoplasia, acetabulum fracture malunion after trauma in 5 cases, 6 patients with rheumatoid arthritis, ankylosing spondylitis hip lesions, 6 cases were performed total hip replacement, take the acetabulum deepening, double cone spiral acetabulum, autologous bone graft and structural methods such as titanium mesh and bone graft line true acetabular reconstruction, all patients preoperative CT three-dimensional reconstruction, with Harris scoring criteria. Results Followed up for 6~36 months, has not occurred during the follow-up period of artificial hip prosthesis loosening and fracture around, etc. Harris scoring (36±6.5) preoperatively, postoperative (93±5.2). Conclusion Deformity of total hip replacement for defects of acetabulum, through the acetabulum, Zweymulle double cone spiral acetabulum, grain pressure distribution, structural bone graft autologous bone graft and titanium mesh and bone graft and so on the many kinds of methods can be a very good reconstruction of acetabulum, restore good stability and the Harris score, can achieve very good effect.%目的探讨髋臼缺损畸形的人工全髋关节置换术的处理方法。方法选取我院收治存在髋臼缺损畸形患者30例,包括髋臼发育不良13例、髋臼创伤骨折后畸形愈合5例、类风湿性关节炎6例,强直性脊柱炎髋关节病变6例,均行全髋关节置换术,采取髋臼加深、双锥  面螺旋型髋臼、自体结构性植骨及钛网加植骨等多种方法行真臼重建,全部病例术前行 CT 三维重建,评分标准采用 Harris 评分。结果随访6~36个月,随访期间未发生人工髋关节假体松动、周围骨折等。Harris 评分术前(36±6.5),术后(93±5.2)。结论对于髋臼缺损畸形的全髋关节置

  3. Hip Revision

    Medline Plus

    Full Text Available ... radiograph, unfortunately, three years down the line, this patient was developing increasing hip pain. And you can ... you on the x-rays, this was a patient that had an infection; and we treated this ...

  4. Hip ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Martinoli, Carlo, E-mail: carlo.martinoli@libero.it [Radiologia, DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Garello, Isabella; Marchetti, Alessandra; Palmieri, Federigo; Altafini, Luisa [Radiologia, DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Valle, Maura [Radiologia, Gaslini Children Hospital, Genova (Italy); Tagliafico, Alberto [Radiologia, National Institute for Cancer Research, Genoa (Italy)

    2012-12-15

    In newborns, US has an established role in the detection and management of developmental dysplasia of the hip. Later in childhood, when the limping child is a major diagnostic dilemma, US is extremely helpful in the identification of the varied disease processes underlying this condition, as transient synovitis, septic arthritis, Perthes disease and slipped femoral capital epiphysis. In adolescent practicing sporting activities, US is an excellent means to identify apophyseal injures about the pelvic ring, especially when avulsions are undisplaced and difficult-to-see radiographically. Later on, in the adulthood, US is an effective modality to diagnose tendon and muscle injuries about the hip and pelvis, identify effusion or synovitis within the hip joint or its adjacent bursae and guide the treatment of these findings. The aim of this article is to provide a comprehensive review of the most common pathologic conditions about the hip, in which the contribution of US is relevant for the diagnostic work-up.

  5. Hip arthroscopy

    Directory of Open Access Journals (Sweden)

    Henrique Antônio Berwanger de Amorim Cabrita

    2015-06-01

    Full Text Available Hip arthroscopy is a safe method for treating a variety of pathological conditions that were unknown until a decade ago. Femoroacetabular impingement is the commonest of these pathological conditions and the one with the best results when treated early on. The instruments and surgical technique for hip arthroscopy continue to evolve. New indications for hip arthroscopy has been studied as the ligamentum teres injuries, capsular repair in instabilities, dissection of the sciatic nerve and repair of gluteal muscles tears (injuries to the hip rotator cuff, although still with debatable reproducibility. The complication rate is low, and ever-better results with fewer complications should be expected with the progression of the learning curve.

  6. Hip ultrasound.

    Science.gov (United States)

    Martinoli, Carlo; Garello, Isabella; Marchetti, Alessandra; Palmieri, Federigo; Altafini, Luisa; Valle, Maura; Tagliafico, Alberto

    2012-12-01

    In newborns, US has an established role in the detection and management of developmental dysplasia of the hip. Later in childhood, when the limping child is a major diagnostic dilemma, US is extremely helpful in the identification of the varied disease processes underlying this condition, as transient synovitis, septic arthritis, Perthes disease and slipped femoral capital epiphysis. In adolescent practicing sporting activities, US is an excellent means to identify apophyseal injures about the pelvic ring, especially when avulsions are undisplaced and difficult-to-see radiographically. Later on, in the adulthood, US is an effective modality to diagnose tendon and muscle injuries about the hip and pelvis, identify effusion or synovitis within the hip joint or its adjacent bursae and guide the treatment of these findings. The aim of this article is to provide a comprehensive review of the most common pathologic conditions about the hip, in which the contribution of US is relevant for the diagnostic work-up. PMID:21571471

  7. 'Hip' pain.

    Science.gov (United States)

    Zacher, Josef; Gursche, Angelika

    2003-02-01

    'Hip' pain is usually located in the groin, upper thigh or buttock and is a common complaint. Slipped capital femoral epiphysis, avascular femoral head necrosis and apophyseal avulsion are the most common diagnoses in childhood and adolescents. Strains and fractures are common in sport-active adults. Osteoarthritis occurs in middle-aged and older adults. Trauma may result in femoral head fracture or typical muscle and tendon sprains and bursitis. Septic or inflammatory arthritis can occur at every age. Septic arthritis, fractures and acute epiphyseal slipping are real emergency cases. Congenital dysplasia of the hip joint may lead to labral tears and early osteoarthritis. The most important hip problems in children, adolescents, adult and older people are discussed; these problems originate from intra-articular disorders and the surrounding extra-articular soft tissues. Medical history, clinical examination and additional tests, including imaging, will be demonstrated. Principles of treatment are given for specific disorders. PMID:12659822

  8. Hip Revision

    Medline Plus

    Full Text Available ... re going to initially look at Scott's preoperative x-rays and just kind of describe the situation that ... up to that time. Here's Scott's initial preoperative x-ray, where we see a hybrid hip arthroplasty with ...

  9. Life Estimation of Hip Joint Prosthesis

    Science.gov (United States)

    Desai, C.; Hirani, H.; Chawla, A.

    2014-11-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  10. Hip dysplasia and congenital hip dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Lingg, G.; Nebel, G.; von Torklus, D.

    1981-11-01

    In human genetics and orthopedics quite different answers have been given to the question of hereditary transmission and frequency of hip dysplasia in families of children with congenital hip dislocation. We therefore have made roentgenometric measurements of 110 parents of children with congenital hip dislocation. In 25% we found abnormal flat acetabulae, whereas 12% had pathologic deep hips. This may propose a new concept of morphology of congenital hip dysplasia.

  11. Hip replacement

    International Nuclear Information System (INIS)

    Patients with problems following implantation of cemented total hip prostheses must be clinically examined. This examination is followed by a series of diagnostic imaging procedures. These include X-ray diagnosis, 3-phase 99mTc-MDP bone scans, scientigraphy for inflammation, and arthrography, performed singly or as sequential studies. X-ray findings and scientigraphic patterns arousing or confirming a suspicion of aseptic (mechanical) or septic (infectious) loosening of the prosthesis are evaluated and discussed. (orig.)

  12. 人工髋关节翻修术的临床原因分析及假体的选择研究%Analysis on clinical causes of revision surgery of artificial hip and choice of prosthesis

    Institute of Scientific and Technical Information of China (English)

    朱正荣; 易洋

    2012-01-01

    目的 探讨人工髋关节置换术后翻修的临床原因及假体的选择.方法 共纳入50例人工髋关节置换术患者,按照距首次行置换术大子或小于5年分为早期组(30例)及晚期组(20例),并按照年龄是否大于50岁分为2组(各25例).均详细记录患者的病史及行翻修术的原因.结果 感染性松动、无菌性松动、假体的磨损、假体周围骨折、关节不稳定均是患者行翻修术的原因,但早期与晚期患者行翻修术的主要原因不同;早期行翻修术的主要原因是感染性松 动、假体周围骨折、关节不稳定,而晚期行翻修术的主要原因为无菌性松动、假体的磨损.对于老年患者选择骨水泥型假体较好,而对于更年轻点的患者选择生物型假体较好.结论 早期行翻修术与晚期行翻修术的主要原因不同,因根据具体情况治疗.对于老年患者选择骨水泥型假体较好,而对于更年轻点的患者选择生物型假体较好,临床可以根据研究对不同患者选用合适的假体.%OBJECTIVE The purpose of this study was to investigate clinical causes of revision surgery of artificial hip and choice of prosthesis. METHODS 50 hospitalized patients with revision of artificial hip were enrolled. According to time to the first replacement surgery longer or shorter than 5 years, the patients were divided into early group (30 cases) and advanced group (20 cases). And according to age whether older than 50 years, the patient were divided into two groups (25 cases in each group). Recorded the patients' case history and causes of revision procedures. RESULTS Infectious loosening, aseptic loosening and wear of false body, fractures around prosthesis, unstable joint were the causes of revision procedures, but patients in the early group and the advanced group had different causes of revision procedures; the main causes of patients in the early group were infectious loosening, fractures around prosthesis and unstable

  13. Bursitis of the Hip

    Science.gov (United States)

    MENU Return to Web version Bursitis of the Hip Overview What is bursitis? Bursitis (say: “burse-eye- ... bursitis is swelling affecting the bursae of the hip. Bursitis does not only happen in the hip. ...

  14. Hip fracture surgery

    Science.gov (United States)

    ... repair; Femoral neck fracture repair; Trochanteric fracture repair; Hip pinning surgery; Osteoarthritis-hip ... top of the bone) you may have a hip pinning procedure. During this surgery: You lie on ...

  15. Hip fracture - discharge

    Science.gov (United States)

    ... 2012:chap 55. Read More Broken bone Hip fracture surgery Hip pain Leg MRI scan Osteoporosis - overview Patient Instructions Getting your home ready - knee or hip surgery Osteomyelitis - discharge Update Date 11/ ...

  16. Ultrasound: Infant Hip

    Science.gov (United States)

    ... ultrasound when they suspect a problem called developmental dysplasia of the hip (DDH) . DDH is a hip deformity that can ... THIS TOPIC X-Ray Exam: Leg Length Developmental Dysplasia of the Hip X-Ray Exam: Hip Contact Us Print Resources ...

  17. Hip replacement - precautions

    Science.gov (United States)

    ... Barker KL, Dewey ME, Sackley CM. Effectiveness of physiotherapy exercise following hip arthroplasty for osteoarthritis: a systematic ... to ask your doctor Hip replacement - discharge Preventing falls - what to ask your doctor Update Date 11/ ...

  18. Taper Hip Prosthesis

    Medline Plus

    Full Text Available ... the minimally invasive anterial lateral approach to the right hip in this gentleman. We're going to ... the anterior superior at the spine of the right hip. And at this point we'll begin. ...

  19. Taper Hip Prosthesis

    Medline Plus

    Full Text Available ... OR Live" Webcast on the Kinectiv Total Hip System. At this time, let’s join Dr. Maltry in ... going to be installing the Zimmer Kinectiv Hip System today and we'll walk you through that. ...

  20. Hip Injuries and Disorders

    Science.gov (United States)

    Your hip is the joint where your thigh bone meets your pelvis bone. Hips are called ball-and-socket joints because the ... a cup-like space in your pelvis. Your hips are very stable. When they are healthy, it ...

  1. Hip supporting device

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to a device for limiting movements in one or more anatomical joints, such as a device for limiting movement in the human hip joint after hip replacement surgery. This is provided by a device for limiting movement in the human hip joint, said device comprising: at least...

  2. Hip arthroscopy in the setting of hip dysplasia

    OpenAIRE

    Yeung, M.; Kowalczuk, M.; Simunovic, N.; Ayeni, O. R.

    2016-01-01

    Objective Hip arthroscopy in the setting of hip dysplasia is controversial in the orthopaedic community, as the outcome literature has been variable and inconclusive. We hypothesise that outcomes of hip arthroscopy may be diminished in the setting of hip dysplasia, but outcomes may be acceptable in milder or borderline cases of hip dysplasia. Methods A systematic search was performed in duplicate for studies investigating the outcome of hip arthroscopy in the setting of hip dysplasia up to Ju...

  3. Do normal hips dislocate?

    Science.gov (United States)

    Alshameeri, Zeiad; Rehm, Andreas

    2014-11-01

    There have been a small number of case reports describing late normal-hip dislocations in children who were later diagnosed with developmental dysplasia of the hip. Here, we contest the assumption that normal hips can dislocate. We argue that (as in our case) the ultrasound scans in all published case reports on late dislocated normal hips did not show results that were entirely normal and therefore, so far, there has been no convincing evidence of a dislocation of a normal hip. We also want to highlight the importance of meticulous ultrasound and clinical assessments of high-risk children by an experienced orthopaedic surgeon. PMID:25144883

  4. The other hip in unilateral hip dysplasia

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Rømer, Lone; Søballe, Kjeld

    2006-01-01

    We reviewed transverse pelvic computed tomography scans of 197 consecutively referred adult patients with hip pain thought to be secondary to developmental dysplasia. A center-edge angle of 20 degrees or less was considered the upper normal value. Four groups were identified: 69 patients...... with apparently unilateral right developmental dysplasia (left hip center-edge angles greater than 20 degrees), 26 patients with apparently unilateral left developmental dysplasia (right hip center-edge angles greater than 20 degrees), 68 patients with bilateral developmental dysplasia, and 34 patients...... with bilateral borderline developmental dysplasia (bilateral center-edge angles less than or equal to 25 degrees). The pelvic computed tomography scans were compared with computed tomography scans of 41 control subjects with healthy hips. The joint anatomy of patients with developmental dysplasia differed from...

  5. Therapeutic Effect of Artificial Total Hip Arthroplasty for the Treatment of the Hip Lesions in the Patients with Ankylosing Spondylitis%人工全髋关节置换术治疗强直性脊柱炎髋关节病变的临床疗效

    Institute of Scientific and Technical Information of China (English)

    刘亮; 张星火; 于振山; 张亚奎; 赵峰; 刘喜波

    2012-01-01

    目的 观察人工全髋关节置换治疗强直性脊柱炎髋关节病变的手术方法和临床效果.方法 对2001年3月至2009年6月26例(31髋)强直性脊柱炎髋关节病变患者行人工全髋关节置换并随访,置换前患者日常活动均明显受限或者严重疼痛,Harris评分平均(43.2±5.8)分,髋关节活动度平均51.8°±9.7°.记录术后末次随访的Harris评分,X线检查结果,观察假体有无松动、脱位及异位骨化. 结果 所有病例得到随访,平均随访24.9(8 ~125)个月.末次随访患者均疼痛消失,步态正常.Harris评分平均(82.4±4.7)分;髋关节活动度平均148.6°±7.4°;髋关节Harris评分及关节活动度均显著高于置换前(P<0.05).2髋出现异位骨化,为Brooker分级Ⅰ、Ⅲ级.无脱位、骨折及假体松动下沉,无患者进行翻修. 结论 人工全髋关节置换是治疗强直性脊柱炎晚期髋关节病变的有效方法,可以恢复关节功能,缓解关节疼痛并改善患者生活质量.%Objective To investigate the operative methods and clinical outcomes of total hip arthroplas-ty (THA) in the treatment of patients with hip lesions due to ankylosing spondylitis (AS). Methods From March 2001 to June 2009, 26 patients (31 hips) with AS received THA. All the hips were severe pain and an-kylosed in average 51. 8° ± 9. 7° of flexion. Preoperative Harris hip score was (43. 2 ±5.8) points. Radio-graphic examination and last Harris score were performed completely at the last time of follow-up. Results All the patients were followed up for average 24.9(8 ~ 125) month. Postoperatively.all patient get pain free and normal gait. According to Brooker system, 2 hips appeared heterotopic ossification, one was of Brookers Class I and the other Class III. No loosening or subsidence occurred in all patients. Harris hip score at final follow-up was (82.4±4.7) points (P <0.05), range of motion of hip were average 148. 6° ±7.4°(P <0. 05). Conclusion THA is effective

  6. Painful Hip Prosthesis: Definition

    OpenAIRE

    Ferrata, P.; Carta, S.; Fortina, M.; Scipio, D.; Riva, A.; Di Giacinto, S.

    2010-01-01

    Pain is the main reason inducing patients to undergo surgery and persistence of pain after the operation is a major concern, both for the patient and the surgeon. Up to 10% of patients report pain five years after hip arthroplasty. An analysis of the literature reveals numerous causes of pain localised to the replacement hip. In assessing a painful hip it is fundamental to arrive at a definite diagnosis before starting any treatment. Intrinsic causes can be identified, such as unrecognised as...

  7. Imaging of hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T., E-mail: millertt@hss.edu [Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021 (United States)

    2012-12-15

    The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.

  8. Hip fracture - discharge

    Science.gov (United States)

    Inter-trochanteric fracture repair - discharge; Subtrochanteric fracture repair - discharge; Femoral neck fracture repair - discharge; Trochanteric fracture repair - discharge; Hip pinning surgery - discharge

  9. Hip Fractures among Older Adults

    Science.gov (United States)

    ... online training for health care providers. Learn More Hip Fractures Among Older Adults Recommend on Facebook Tweet ... get older. What You Can Do to Prevent Hip Fractures You can prevent hip fractures by taking ...

  10. CONSERVATIVE TREATMENT OF HIP DYSPLASIA

    OpenAIRE

    Mikhail Mikhailovich Kamosko; Mahmoud Stanislavovich Poznovich

    2014-01-01

    Hip dysplasia in children is the subject of careful study by specialists both in our country and abroad. There are three basic variants of hip dysplasia: congenital acetabular dysplasia, congenital subluxation of the hip and congenital dislocation of the hip. However, treatment of congenital dislocation of the hip, which is the most severe form of hip dysplasia in children, currently remains one of the topical problems of children’s orthopedics, despite the significant achievements of modern ...

  11. Taper Hip Prosthesis

    Medline Plus

    Full Text Available Zimmer M/L Taper Hip Prosthesis with Modular Neck Kinectiv® Technology March 12, 2009 7:00 PM EDT Welcome to this "OR Live" Webcast presentation ... an "OR Live" Webcast on the Kinectiv Total Hip System. At this time, let’s join Dr. Maltry ...

  12. Hip Problems in Infants

    Science.gov (United States)

    ... problems that can lead to dislocation of the hip bones. This is also called dysplasia (say: "diss-play-see-uh"). This means that ... problems later in life? Source Screening for Developmental Dysplasia of the Hip by LM French, M.D., and FR Dietz, ...

  13. TREATMENT OF HIP DYSPLASIA

    Directory of Open Access Journals (Sweden)

    Iulian ICLEANU

    2015-11-01

    Full Text Available In this thesis, our purpose is to show that using physiotherapy on patients with hip dysplasia from the very beginning, in the first months of life, helps treating them faster. Common literature proposes to use physiotherapy on patients with hip dysplasia either after their recovery or in the terminal phase of recovery, claiming that any earlier intervention will prolong the hip recovery. The effects of hip dysplasia reflect over the whole musculoskeletal system, while it hinders the knees (genu valgum, the ankles (ankle valgus, calcaneal valgus and the spine (scoliosis especially at the lumbar level. The most spectacular are at the hip level, that is why we made an analytical evaluation only for this joint. To show the importance of physiotherapy for children with hip dysplasia we started from the hypothesis: untimely treatment for children with hip dysplasia has improved results in functional recovery and in obtaining a better stability, without the necessity of orthopedics or surgical interventions. The research methods used in this study are: the observation method, the bibliographic study method, the experimental method, the graphics method and the statistical mathematical method to process the data and to represent the results graphically. In the end, the results obtained are significantly different from the initial evaluations and we came to the conclusion that starting an untimely analytical kinetic treatment and globally personalizing it to every patient improves stability and biomechanical parameters for the hip.

  14. Hip joint injection

    Science.gov (United States)

    ... cause of the pain. For some, it can last weeks or months. Alternative Names Cortisone shot - hip; Hip injection; Intra-articular steroid ... writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Contact ... Institutes of Health Page last updated: 23 August 2016

  15. Artificial intelligence

    CERN Document Server

    Hunt, Earl B

    1975-01-01

    Artificial Intelligence provides information pertinent to the fundamental aspects of artificial intelligence. This book presents the basic mathematical and computational approaches to problems in the artificial intelligence field.Organized into four parts encompassing 16 chapters, this book begins with an overview of the various fields of artificial intelligence. This text then attempts to connect artificial intelligence problems to some of the notions of computability and abstract computing devices. Other chapters consider the general notion of computability, with focus on the interaction bet

  16. Total Hip Arthroplasty for Hip Fractures

    Science.gov (United States)

    Monzón, Daniel Godoy; Iserson, Kenneth V.; Jauregui, José; Musso, Carlos; Piccaluga, Francisco; Buttaro, Martin

    2014-01-01

    Introduction: This study aimed to determine the dislocation and reoperation rate, functional outcomes, and the survival rate of the unique subset of very old but lucid and independent patients with hip fractures following a total hip arthroplasty (THA) and geriatric team-coordinated perioperative care. Method: Between 2000 and 2006, previously independent ambulatory patients ≥80 years old presenting with an intracapsular hip fracture were given THAs under the care of an integrated orthopedic surgery–geriatric service. Their fracture-related complications, ambulation, mental status, and survival were followed for 5 to 11 years postinjury. Results: Five years postinjury, 57 (61.3%) patients of the original study group were living. In all, 3 (3.2%) patients had postoperative hip dislocations (and 2 patients had dislocation twice) and 2 reoperations were needed within the first postoperative month. There were no hip dislocations or reoperations after the first year. Radiographs obtained on 88% of the surviving patients at 5 years postoperatively showed that all remained unchanged from their immediate postoperative images. Nearly half of the patients were still able to ambulate as they did preoperatively and their mixed-model equation was statistically unchanged. Conclusion: This study of patients >80 years old with previously good functional status demonstrates that with appropriate surgical (best prosthesis, good operating technique, and regional anesthesia) and geriatric (pre- and postoperative assessments, close follow-up, medication adjustments, and fall-prevention instruction) care, they have few hip dislocations and reoperations, survive postfracture at least as long as their noninjured contemporaries, and continue to function and ambulate as they did prior to their injury. PMID:24660092

  17. Formed HIP Can Processing

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, Kester Diederik [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-07-27

    The intent of this report is to document a procedure used at LANL for HIP bonding aluminum cladding to U-10Mo fuel foils using a formed HIP can for the Domestic Reactor Conversion program in the NNSA Office of Material, Management and Minimization, and provide some details that may not have been published elsewhere. The HIP process is based on the procedures that have been used to develop the formed HIP can process, including the baseline process developed at Idaho National Laboratory (INL). The HIP bonding cladding process development is summarized in the listed references. Further iterations with Babcock & Wilcox (B&W) to refine the process to meet production and facility requirements is expected.

  18. 优质护理对人工髋关节置换术患者功能锻炼依从性的影响%Effect of high quality nursing service on the patient compliance of functional exercise after artificial hip replacement

    Institute of Scientific and Technical Information of China (English)

    周泽慧; 林丽贤

    2013-01-01

    Objective:To investigate the effect of high quality nursing care on the patient compliance of functional exercise after artificial hip replacement .Methods:143 patients underwent artificial hip replacement in our hospital were divided into the observation group ( n=73) and the control group (n=70) in accordance with the time of admission.The patients in the control group were given preoperative and postoperative nursing care and received routine follow -up after discharge;the high quality nursing service was implemnted in the observa-tion group and the patients in this group were provided holistic nursing care ,inluding three level nursing round ,the responsibility system of nursing team leader ,stratified nursing management ,enabling bedside workstation ,the continuous and extended nursing care from admission to discharge provided by the bedside nurse .Results:The cognitive degree of the operation and functional exercise and compliance of func -tional exercise of the patients was significantly higher and better in the observation group than the control group ,the incidence of complica-tions was lower in the observation group than the control group (P<0.05).Conclusion:The high quality nursing service can improve the cognition level of the patients with artificial hip replacement ,enhance their compliance of functional exercise ,reduce the incidence of post-operative complications and promote their recovery .%目的:探讨优质护理服务对人工髋关节置换患者功能锻炼依从性的影响。方法:将143例在我院接受人工髋关节置换术的患者按照收治的时间段分为观察组73例和对照组70例,对照组遵医嘱按时完成各项治疗,按常规护理方法进行术前、术后护理,出院后常规随访;观察组通过开展优质护理服务,实行三级护理查房,采用护理组长责任制、分层级护理管理模式,启用床边工作站,由管床责任护士负责对患者提供从入院到出院、出

  19. CONSERVATIVE TREATMENT OF HIP DYSPLASIA

    Directory of Open Access Journals (Sweden)

    Михаил Михайлович Камоско

    2014-12-01

    Full Text Available Hip dysplasia in children is the subject of careful study by specialists both in our country and abroad. There are three basic variants of hip dysplasia: congenital acetabular dysplasia, congenital subluxation of the hip and congenital dislocation of the hip. However, treatment of congenital dislocation of the hip, which is the most severe form of hip dysplasia in children, currently remains one of the topical problems of children’s orthopedics, despite the significant achievements of modern medicine. In spite of the large amount of research in this field, treatment principles of hip dysplasia are still under discussion.

  20. Artificial Limbs

    Science.gov (United States)

    ... you are missing an arm or leg, an artificial limb can sometimes replace it. The device, which ... activities such as walking, eating, or dressing. Some artificial limbs let you function nearly as well as ...

  1. Hip arthroscopy in the setting of hip dysplasia

    Science.gov (United States)

    Yeung, M.; Kowalczuk, M.; Simunovic, N.

    2016-01-01

    Objective Hip arthroscopy in the setting of hip dysplasia is controversial in the orthopaedic community, as the outcome literature has been variable and inconclusive. We hypothesise that outcomes of hip arthroscopy may be diminished in the setting of hip dysplasia, but outcomes may be acceptable in milder or borderline cases of hip dysplasia. Methods A systematic search was performed in duplicate for studies investigating the outcome of hip arthroscopy in the setting of hip dysplasia up to July 2015. Study parameters including sample size, definition of dysplasia, outcomes measures, and re-operation rates were obtained. Furthermore, the levels of evidence of studies were collected and quality assessment was performed. Results The systematic review identified 18 studies investigating hip arthroscopy in the setting of hip dysplasia, with 889 included patients. Criteria used by the studies to diagnose hip dysplasia and borderline hip dysplasia included centre edge angle in 72% of studies but the range of angles were quite variable. Although 89% of studies reported improved post-operative outcome scores in the setting of hip dysplasia, revision rates were considerable (14.1%), with 9.6% requiring conversion to total hip arthroplasty. Conclusion The available orthopaedic literature suggests that although improved outcomes are seen in hip arthroscopy in the setting of hip dysplasia, there is a high rate of re-operation and conversion to total hip arthroplasty. Furthermore, the criteria used to define hip dysplasia vary considerably among published studies. Cite this article: M. Yeung, M. Kowalczuk, N. Simunovic, O. R. Ayeni. Hip arthroscopy in the setting of hip dysplasia: A systematic review. Bone Joint Res 2016;5:225–231. DOI: 10.1302/2046-3758.56.2000533. PMID:27313136

  2. Taper Hip Prosthesis

    Medline Plus

    Full Text Available ... L Taper Hip Prosthesis with Modular Neck Kinectiv® Technology March 12, 2009 7:00 PM EDT Welcome ... hopefully you will see the benefits and the advantages of the new Zimmer Kinectiv System. Thank you. ...

  3. Taper Hip Prosthesis

    Medline Plus

    Full Text Available ... on the Kinectiv Total Hip System. At this time, let’s join Dr. Maltry in the operating room. ... you show us that leg position one more time? Can we show his front view of how ...

  4. Imaging of hip arthroplasty

    International Nuclear Information System (INIS)

    Hip arthroplasty has become a common and still increasing procedure for the treatment of osteoarthritis, advanced head necrosis, post-inflammatory arthritis or rheumatoid arthritis.Radiography is the most important imaging modality for monitoring the normal, asymptomatic hip arthroplasty. Radiographs are obtained at the end of a surgical treatment, to exclude complications like fracture or component misplacement. In the follow-up radiographs are used for the diagnosis of loosening and infection of the hip arthroplasty as well as soft tissue ossification. Together with the history and clinical information, the analysis of morphological findings allows to find the grade of loosening. MRI has been advocated in the diagnosis of infection, in particular in the localisation of soft tissue involvement.Imaging, especially by radiographs, is used for the evaluation of the normal and complicated follow-up of hip arthroplasty. (orig.)

  5. Treatment of hip dysplasia.

    Science.gov (United States)

    Anderson, A

    2011-04-01

    Hip dysplasia is a common orthopaedic developmental disorder of dogs. This paper reviews the treatment options available for management of the condition in the skeletally immature and adult dog. PMID:21906059

  6. Taper Hip Prosthesis

    Medline Plus

    Full Text Available Zimmer M/L Taper Hip Prosthesis with Modular Neck Kinectiv® Technology March 12, 2009 7:00 PM EDT Welcome to this "OR Live" Webcast presentation brought to you by Zimmer. During ...

  7. Hip flexor strain - aftercare

    Science.gov (United States)

    ... such as sprinting, kicking, and changing direction while running or moving, can stretch and tear the hip flexors. Runners, people who do martial arts, and football, soccer, and hockey players are more likely to have ...

  8. HIP osteoarthritis and work.

    Science.gov (United States)

    Harris, E Clare; Coggon, David

    2015-06-01

    Epidemiological evidence points strongly to a hazard of hip osteoarthritis from heavy manual work. Harmful exposures may be reduced by the elimination or redesign of processes and the use of mechanical aids. Reducing obesity might help to protect workers whose need to perform heavy lifting cannot be eliminated. Particularly high relative risks have been reported in farmers, and hip osteoarthritis is a prescribed occupational disease in the UK for long-term employees in agriculture. Even where it is not attributable to employment, hip osteoarthritis impacts importantly on the capacity to work. Factors that may influence work participation include the severity of disease, the physical demands of the job, age and the size of the employer. Published research does not provide a strong guide to the timing of return to work following hip arthroplasty for osteoarthritis, and it is unclear whether patients should avoid heavy manual tasks in their future employment. PMID:26612242

  9. Arthroscopic hip labral repair.

    Science.gov (United States)

    Philippon, Marc J; Faucet, Scott C; Briggs, Karen K

    2013-05-01

    Labral tears in the hip may cause painful clicking or locking of the hip, reduced range of motion, and disruption to sports and daily activities. The acetabular labrum aids stabilization of the hip joint, particularly during hip motion. The fibrocartilaginous structure extends the acetabular rim and provides a suction seal around the femoroacetabular interface. Treatment options for labral tears include debridement, repair, and reconstruction. Repair of the labrum has been shown to have better results than debridement. Labral refixation is achieved with sutures anchored into the acetabular rim. The acetabular rim is trimmed either to correct pincer impingement or to provide a bleeding bed to improve healing. Labral repair has shown excellent short-term to midterm outcomes and allows patients to return to activities and sports. Arthroscopic rim trimming and labral refixation comprise an effective treatment for labral tears with an underlying diagnosis of femoroacetabular impingement and are supported by the peer-reviewed literature. PMID:23875153

  10. Hip fracture surgeries

    Science.gov (United States)

    ... nih.gov/pubmed/20837683 . Weinlein JC. Fractures and dislocations of the hip. In: Canale ST, Beaty JH, eds. Campbell's Operative ... Ma, MD, Assistant Professor, Chief, Sports Medicine and Shoulder Service, UCSF Department of Orthopaedic Surgery, San Francisco, ...

  11. HIP osteoarthritis and work

    OpenAIRE

    Harris, E C; Coggon, D.

    2015-01-01

    Epidemiological evidence points strongly to a hazard of hip osteoarthritis from heavy manual work. Harmful exposures may be reduced by the elimination or redesign of processes and the use of mechanical aids. Reducing obesity might help to protect workers whose need to perform heavy lifting cannot be eliminated. Particularly high relative risks have been reported in farmers, and hip osteoarthritis is a prescribed occupational disease in the UK for long-term employees in agriculture. Even where...

  12. Radiological Assessment of the Sacrofemoral Angle: A Novel Method to Measure the Range of Hip Joint Flexion

    OpenAIRE

    Xian-Zhao Wei; Xi-Ming Xu; Fei Wang; Ming Li; Zi-Min Wang

    2015-01-01

    Background: A quantitative and accurate measurement of the range of hip joint flexion (RHF) is necessarily required in the evaluation of disordered or artificial hip joint function. This study aimed to assess a novel method to measure RHF more accurately and objectively. Methods: Lateral radiographs were taken of 31 supine men with hip joints extended or flexed. Relevant angles were measured directly from the radiographs. The change in the sacrofemoral angle (SFA) (the angle formed between th...

  13. Experimental study on the pathogenesis of deep venous thrombosis in lower limbs following artificial total hip replacement%人工全髋关节置换术后下肢深静脉血栓形成原因的实验观察

    Institute of Scientific and Technical Information of China (English)

    杨景武; 史晓林

    2005-01-01

    不良事件及副反应:3例出血达1 000 mL.为充分暴露手术视野,用拉钩阻挡肌肉等组织,即造成血管的长期积压,血流迟缓.结论:人工全髋置换术易损伤髋臼血管内壁,从而导致血流减慢和血小板聚集,最终促使血栓形成.同时术中失血多,使血液黏稠导致血栓形成.根据易损伤区及安全区模式图可知,下肢深静脉血栓是可以减少的.%BACKGROUND:Deep venous thrombosis has already been recognized as an important serious postoperative complication because it can cause fatal pulmonary embolism and long-term deep venous dysfunction. With the constant development of artificial joint operation and the popularization of such surgery, much attention has been paid to the formation of deep venous thrombosis following artificial joint replacement.OBJECTIVE: To observe the anatomical property of acetabular surrounding arteries and veins, as well as their injury during total hip replacement,so as to explore the cause of deep venous thrombosis in lower limbs following artificial total hip replacement.DESIGN: Single sample observation and before-after self-control.SETTING: Gross anatomy was carried out in the anatomical laboratory of the Medical School of Huzhou Teachers' College; total hip replacement was carried out in the Orthopedic Department, Xinhua Hospital of Zhejiang Traditional Chinese Medicine College.PARTICIPANTS: Pelvic samples were collected from 60 normal adult corpuses (30 from men and 30 from women); meanwhile, 30 patients (18 males and 12 females) received total hip replacement in the Orthopedic Department of Xinhua Hospital, Zhejiang Traditional Chinese Medicine College, between March 2002 and August 2003.METHODS: Gross anatomy was carried out at the anatomical laboratory in the Medical School of Huzhou Teachers' College between March and May 2003. The running course of bilateral external iliac artery and vein, as well as the relationship between the branches of femoral artery and vein and acetabulum were

  14. Bipolar hip arthroplasty.

    Science.gov (United States)

    Chang, Qing; Liu, Shubing; Guan, Changyong; Yu, Fangyuan; Wu, Shenguang; Jiang, Changliang

    2011-12-01

    Our aim was to compare hip arthroplasty with internal screw fixation in the repair of intertrochanteric fractures in elderly patients with osteoporosis. Of 112 included patient, 70 (81.81 ± 4.88 years) received hip arthroplasty with a prosthesis specially designed for intertrochanteric fractures, and 42 (83.46 ± 5.11 years) underwent plate-screw fixation. The hip arthroplasty group had significantly longer operation time, intraoperative blood loss, and total volume of blood transfused but had shorter time to beginning weight-bearing (5.94 ± 2.76 vs 23.68 ± 22.01 days) and higher postoperative Harris hip score (91.37 ± 4.80 vs 86.14 ± 5.46). In the arthroplasty group, there were 2 dislocations; and in the plate-screw fixation group, there were 5 internal fixation failures. Hip arthroplasty is preferable to internal fixation in elderly patients (age >80 years) with osteoporosis. PMID:21530148

  15. X-Ray Exam: Hip

    Science.gov (United States)

    ... Tropical Delight: Melon Smoothie Pregnant? Your Baby's Growth X-Ray Exam: Hip KidsHealth > For Parents > X-Ray Exam: Hip Print A A A Text Size ... español Radiografía: cadera What It Is A hip X-ray is a safe and painless test that uses ...

  16. Artificial blood

    Directory of Open Access Journals (Sweden)

    Sarkar Suman

    2008-01-01

    Full Text Available Artificial blood is a product made to act as a substitute for red blood cells. While true blood serves many different functions, artificial blood is designed for the sole purpose of transporting oxygen and carbon dioxide throughout the body. Depending on the type of artificial blood, it can be produced in different ways using synthetic production, chemical isolation, or recombinant biochemical technology. Development of the first blood substitutes dates back to the early 1600s, and the search for the ideal blood substitute continues. Various manufacturers have products in clinical trials; however, no truly safe and effective artificial blood product is currently marketed. It is anticipated that when an artificial blood product is available, it will have annual sales of over $7.6 billion in the United States alone.

  17. Hip Arthroscopy: A Brief History.

    Science.gov (United States)

    Kandil, Abdurrahman; Safran, Marc R

    2016-07-01

    Hip arthroscopy is a fast-growing and evolving field. Like knee and shoulder arthroscopy, hip arthroscopy began as a diagnostic procedure and then progressed to biopsy and resection of abnormalities. Subsequently, it has evolved to repair of various tissues and treatment of underlying causes. As the understanding of the hip joint and its associated pathophysiology grows, indications will continue to expand for this diagnostic and therapeutic modality. This article outlines the historic developments of hip arthroscopy, including advancements in instrumentation and techniques from the days of the first hip arthroscopies to the present day. PMID:27343387

  18. The painful hip: new concepts

    Energy Technology Data Exchange (ETDEWEB)

    Blankenbaker, Donna G.; Tuite, Michael J. [University of Wisconsin Medical School, Department of Radiology, Division of Musculoskeletal Imaging, Madison, WI (United States)

    2006-06-15

    Hip pain is a common condition, and the work-up often includes imaging. This article reviews the normal MR anatomy of the hip and the imaging findings of internal derangements, snapping hip, and femoral acetabular impingement. We will describe the role of MR arthrography in evaluating the patient with suspected labral and articular cartilage abnormalities, as well as the pitfalls in interpretation. We will review the causes of a snapping hip, and the role of sonography in evaluating and guiding treatment of the snapping iliopsoas tendon. We will also review the radiographic and MRI signs of femoroacetabular impingement (FAI), a cause of early degenerative joint disease and hip pain. (orig.)

  19. The athlete's hip and groin.

    Science.gov (United States)

    Tammareddi, Kumar; Morelli, Vincent; Reyes, Miguel

    2013-06-01

    Groin and hip injuries are seen in athletes who perform quick directional changes and cutting movements. Because forces generated through athletic performance are transferred through the hip, injuries to these areas may limit athletes with mild pain or lead to career-ending injuries. The anatomy of the hip and groin is complex and symptoms often overlap. This article discusses some athletic causes, but other medical conditions may be associated with hip and groin pain as well. Updates in evaluation and treatment are discussed for adductor strains, hip osteoarthritis, femoroacetabular impingement, sports hernia, osteitis pubis, and obturator nerve entrapment. PMID:23668647

  20. Taper Hip Prosthesis

    Medline Plus

    Full Text Available Zimmer M/L Taper Hip Prosthesis with Modular Neck Kinectiv® Technology March 12, 2009 7:00 PM EDT Welcome to this "OR Live" Webcast presentation brought to ... approximately one centimeter to the shoulder of my prosthesis. And then I will simply use the prosthesis ...

  1. Massive Deposition and Accumulation of Hydroxyapatite Crystal after Total Hip Arthroplasty: A Case Report

    OpenAIRE

    Shin Yamada; Koji Nozaka; Hidetomo Saito; Hiroaki Kijima; Hiroshi Tazawa; Yasusi Takasaki; Yoichi Shimada

    2013-01-01

    We presented a case in which massive hydroxyapatite accumulation was observed around the artificial hip joint. A 66-year-old female showed a massive accumulation of fluid in and around the hip joint, and milk-like aspirate was obtained. Her aspirate culture was negative, and sediment analysis by X-ray diffraction showed that its component was hydroxyapatite. Since pain was mild, the patient was treated conservatively. To our knowledge, this is the first case in which liquid hydroxyapatite (mi...

  2. Artificial intelligence

    CERN Document Server

    Ennals, J R

    1987-01-01

    Artificial Intelligence: State of the Art Report is a two-part report consisting of the invited papers and the analysis. The editor first gives an introduction to the invited papers before presenting each paper and the analysis, and then concludes with the list of references related to the study. The invited papers explore the various aspects of artificial intelligence. The analysis part assesses the major advances in artificial intelligence and provides a balanced analysis of the state of the art in this field. The Bibliography compiles the most important published material on the subject of

  3. Artificial urushi.

    Science.gov (United States)

    Kobayashi, S; Uyama, H; Ikeda, R

    2001-11-19

    A new concept for the design and laccase-catalyzed preparation of "artificial urushi" from new urushiol analogues is described. The curing proceeded under mild reaction conditions to produce the very hard cross-linked film (artificial urushi) with a high gloss surface. A new cross-linkable polyphenol was synthesized by oxidative polymerization of cardanol, a phenol derivative from cashew-nut-shell liquid, by enzyme-related catalysts. The polyphenol was readily cured to produce the film (also artificial urushi) showing excellent dynamic viscoelasticity. PMID:11763444

  4. Artificial Reefs

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — An artificial reef is a human-made underwater structure, typically built to promote marine life in areas with a generally featureless bottom, control erosion, block...

  5. Natural - synthetic - artificial!

    DEFF Research Database (Denmark)

    Nielsen, Peter E

    2010-01-01

    The terms "natural," "synthetic" and "artificial" are discussed in relation to synthetic and artificial chromosomes and genomes, synthetic and artificial cells and artificial life.......The terms "natural," "synthetic" and "artificial" are discussed in relation to synthetic and artificial chromosomes and genomes, synthetic and artificial cells and artificial life....

  6. Total hip replacement in young adults with hip dysplasia

    OpenAIRE

    Engesæter, Ingvild Ø; Lehmann, Trude; Laborie, Lene B; Lie, Stein Atle; Rosendahl, Karen; Engesæter, Lars B

    2011-01-01

    Background and purpose Dysplasia of the hip increases the risk of secondary degenerative change and subsequent total hip replacement. Here we report on age at diagnosis of dysplasia, previous treatment, and quality of life for patients born after 1967 and registered with a total hip replacement due to dysplasia in the Norwegian Arthroplasty Register. We also used the medical records to validate the diagnosis reported by the orthopedic surgeon to the register. Methods Subjects born after Janua...

  7. Heterotopic ossification after hip arthroscopy.

    Science.gov (United States)

    Amar, Eyal; Sharfman, Zachary T; Rath, Ehud

    2015-12-01

    Heterotopic ossification (HO) after hip arthroscopy is the abnormal formation of mature lamellar bone within extra skeletal soft tissues. HO may lead to pain, impaired range of motion and possibly revision surgery. There has been a substantial amount of recent research on the pathophysiology, prophylaxis and treatment of HO associated with open and arthroscopic hip surgery. This article reviews the literature on the aforementioned topics with a focus on their application in hip arthroscopy. PMID:27011859

  8. Heterotopic ossification after hip arthroscopy

    OpenAIRE

    Amar, Eyal; Sharfman, Zachary T.; Rath, Ehud

    2015-01-01

    Heterotopic ossification (HO) after hip arthroscopy is the abnormal formation of mature lamellar bone within extra skeletal soft tissues. HO may lead to pain, impaired range of motion and possibly revision surgery. There has been a substantial amount of recent research on the pathophysiology, prophylaxis and treatment of HO associated with open and arthroscopic hip surgery. This article reviews the literature on the aforementioned topics with a focus on their application in hip arthroscopy.

  9. Infant hip sonography: current concepts.

    Science.gov (United States)

    Harcke, H T; Grissom, L E

    1994-08-01

    Sonography of the infant hip has gained wide acceptance in the decade since its introduction. The two principle techniques of Graf and Harcke have been combined with the proposal of a Dynamic Standard Minimum Examination. Whereas sonography is used increasingly to manage developmental dislocation and/or displasia of the hip, there is no agreement on the use of sonography for universal newborn screening. This article describes in detail the Dynamic Standard Minimum Sonographic Examination of the infant hip. In addition, this article reviews the classification and management of infant hip disorders. PMID:7946476

  10. Schizophrenia, antipsychotics and risk of hip fracture

    DEFF Research Database (Denmark)

    Sørensen, Holger J; Jensen, Signe O W; Nielsen, Jimmi

    2013-01-01

    (matched to 1:3 to schizophrenia controls without hip fracture), antipsychotic polypharmacy predicted hip fracture. Analyses among antipsychotic monotherapy patients showed no differential effect of individual antipsychotics. A dose-response relationship of hip fracture and lifetime antipsychotics...

  11. Artificial noses.

    Science.gov (United States)

    Stitzel, Shannon E; Aernecke, Matthew J; Walt, David R

    2011-08-15

    The mammalian olfactory system is able to detect many more odorants than the number of receptors it has by utilizing cross-reactive odorant receptors that generate unique response patterns for each odorant. Mimicking the mammalian system, artificial noses combine cross-reactive sensor arrays with pattern recognition algorithms to create robust odor-discrimination systems. The first artificial nose reported in 1982 utilized a tin-oxide sensor array. Since then, however, a wide range of sensor technologies have been developed and commercialized. This review highlights the most commonly employed sensor types in artificial noses: electrical, gravimetric, and optical sensors. The applications of nose systems are also reviewed, covering areas such as food and beverage quality control, chemical warfare agent detection, and medical diagnostics. A brief discussion of future trends for the technology is also provided. PMID:21417721

  12. Artificial intelligence

    International Nuclear Information System (INIS)

    A vivid example of the growing need for frontier physics experiments to make use of frontier technology is in the field of artificial intelligence and related themes. This was reflected in the second international workshop on 'Software Engineering, Artificial Intelligence and Expert Systems in High Energy and Nuclear Physics' which took place from 13-18 January at France Telecom's Agelonde site at La Londe des Maures, Provence. It was the second in a series, the first having been held at Lyon in 1990

  13. Artificial Intelligence

    CERN Document Server

    Warwick, Kevin

    2011-01-01

    if AI is outside your field, or you know something of the subject and would like to know more then Artificial Intelligence: The Basics is a brilliant primer.' - Nick Smith, Engineering and Technology Magazine November 2011 Artificial Intelligence: The Basics is a concise and cutting-edge introduction to the fast moving world of AI. The author Kevin Warwick, a pioneer in the field, examines issues of what it means to be man or machine and looks at advances in robotics which have blurred the boundaries. Topics covered include: how intelligence can be defined whether machines can 'think' sensory

  14. Development and Physical Control Research on Prototype Artificial Leg

    OpenAIRE

    Fei Li; Fuming Zhang; Hualong Xie

    2016-01-01

    To provide an ideal platform for research on intelligent bionic leg (IBL), this paper proposes a model of a biped robot with heterogeneous legs (BRHL). A prototype of an artificial leg is developed based on biological structure and motion principle analysis of human lower extremities. With regard to the driving sources, servomotors are chosen for the hip joint and ankle joint, while pneumatic muscle actuators (PMAs) are chosen for the knee joint. The control system of the bionic artificial le...

  15. Hip Hip Hurrah! Hip size inversely related to heart disease and total mortality

    DEFF Research Database (Denmark)

    Heitmann, B L; Lissner, L

    2011-01-01

    obesity and/or waist circumference. These studies have been remarkable in terms of their consistency, and in the unexpected finding of an adverse effect of small hip size, after statistically correcting for differences in general and abdominal size. The hazard related to a small hip size may be stronger......During the past decade a series of published reports have examined the value of studying the relation between hip circumferences and cardiovascular end points. Specifically, in a series of recent studies the independent effects of hip circumference have been studied after adjustment for general...

  16. Artificial sweeteners

    DEFF Research Database (Denmark)

    Raben, Anne Birgitte; Richelsen, Bjørn

    2012-01-01

    Artificial sweeteners can be a helpful tool to reduce energy intake and body weight and thereby risk for diabetes and cardiovascular diseases (CVD). Considering the prevailing diabesity (obesity and diabetes) epidemic, this can, therefore, be an important alternative to natural, calorie-containin...

  17. Artificial photosynthesis

    OpenAIRE

    Andrew C. Benniston; Anthony Harriman

    2008-01-01

    We raise here a series of critical issues regarding artificial photosynthesis with the intention of increasing awareness about what needs to be done to bring about a working prototype. Factors under consideration include energy and electron transfers, coupled redox reactions, repair mechanisms, and integrated photosystems.

  18. Hip-Hop Education Resources

    Science.gov (United States)

    Hall, Marcella Runell

    2009-01-01

    Hip-hop music and culture are often cited as being public pedagogy, meaning the music itself has intrinsic educational value. Non-profit organizations and individual educators have graciously taken the lead in utilizing hip-hop to educate. As the academy continues to debate its effectiveness, teachers and community organizers are moving forward.…

  19. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... and E-poly antioxidant-infused technology during a hip replacement through the anterior supine intramuscular approach. “OR- ... Dr. Keith Berend perform an anterior approach total hip replacement with the patient on a regular OR ...

  20. Hip sonography in the newborn

    International Nuclear Information System (INIS)

    The authors report the data relative to 1507 cases studied with clinical and US examinations, in the neonatal period, in order to exclude hip dysplasia dislocation. US examination was carried out according to Graf's technique and the newborns were classified according to US hip type, to clinical examination and to possible risk factors. The patients were included in a protocol including orthopedic and US controls. Seventeen treated infants were considered as pathologic. Ten of them had IIc or D hips ar birth; the other 7, with IIa hips at birth, presented a X-ray pathologic hip after the 4th months of life. At about one year of age all infants could normally walk, excpet for one who was being treated with herness. No statistically significant differences were observed between the number of pathologic infants in the risk group (1.7%) and that in the no-risk group (0.8%). Clinical examination of the newborn has low sensitivity in detecting pathologic hips. On the basis of their results, thw authors belive US examination of the newborn to be a valuable screening method to diagnose hip dysplasia/dislocation. Moreover, Graf's morphologic method is the best one for US screening of the hip in the neonatal period

  1. Social inequality and hip fracture

    DEFF Research Database (Denmark)

    Harvey, N. C.; Hansen, L.; Judge, A.;

    2015-01-01

    Social inequality appears to be increasing in many countries. We explored whether risk of hip fracture was associated with markers of inequality and whether these relationships changed with time, using data from Danish Health Registries. Methods: All patients 60 years or older with a primary hip...... fracture (ICD10: S720, S721, S722 and S729) were identified from 1 January 1995 to 31 December 2011. Hip fracture patients were matched 1:1 on age, gender and year of fracture to a non-hip fracture control. An individual's education attainment was defined as basic, secondary or higher, and their income was...... taken from their latest registered annual tax return (600,000 DKK). Poisson regression modeling was used to describe the association between income or education with rate of hip fracture, adjusting for confounders (smoking, alcohol, Charlson co-morbidity). Interactions were fitted between income and...

  2. Validation of computer models of an artificial hip joint

    Directory of Open Access Journals (Sweden)

    S. Ziemba

    2007-05-01

    Full Text Available Purpose: Problems of the modelling of the surgical cement behaviour during implantation have been presented in the paper. The purpose was to validate the FEM model describing the temperature fields in the bone during the surgery treatment.Design/methodology/approach: The physical laboratory modelling has been used to perform validation of the model that makes it possible to predict the temperature influence on the bone tissue during polymerization process.Findings: Due to its non-invasive nature, the computer models’ validation method applied in the study seems to be the right solution for the research on surgical procedures of endoprosthesis implantation. However, a particular emphasis should be placed on a correct selection of thermophysical properties of the designed laboratory models. Relying on the calculations and research results, similar local values of maximum temperatures were obtained. Practical implications: The computer modelling methods presented in the paper together with the analytical approach are of great importance to both forecasting the implants’ behaviour during a surgical procedure and in their operational conditions, as well as in the selection and modification process of surgical cements’ material properties. The analysis carried out makes it possible to determine the location of zones most threatened with an adverse effect of an elevated temperature. They are located in the vicinity of the top of the endoprosthesis stem.Originality/value: The work presents the own method of validation of the FEM model used for heat flow modelling.

  3. Artificial Intelligence.

    Science.gov (United States)

    Lawrence, David R; Palacios-González, César; Harris, John

    2016-04-01

    It seems natural to think that the same prudential and ethical reasons for mutual respect and tolerance that one has vis-à-vis other human persons would hold toward newly encountered paradigmatic but nonhuman biological persons. One also tends to think that they would have similar reasons for treating we humans as creatures that count morally in our own right. This line of thought transcends biological boundaries-namely, with regard to artificially (super)intelligent persons-but is this a safe assumption? The issue concerns ultimate moral significance: the significance possessed by human persons, persons from other planets, and hypothetical nonorganic persons in the form of artificial intelligence (AI). This article investigates why our possible relations to AI persons could be more complicated than they first might appear, given that they might possess a radically different nature to us, to the point that civilized or peaceful coexistence in a determinate geographical space could be impossible to achieve. PMID:26957450

  4. Artificial intelligence

    OpenAIRE

    Duda, Antonín

    2009-01-01

    Abstract : Issue of this work is to acquaint the reader with the history of artificial inteligence, esspecialy branch of chess computing. Main attention is given to progress from fifties to the present. The work also deals with fighting chess programs against each other, and against human opponents. The greatest attention is focused on 1997 and duel Garry Kasparov against chess program Deep Blue. The work is divided into chapters according to chronological order.

  5. Calculating the hip center of rotation using contralateral pelvic anatomy.

    Science.gov (United States)

    Durand-Hill, Matthieu; Henckel, Johann; Satchithananda, Keshthra; Sabah, Shiraz; Hua, Jia; Hothi, Harry; Langstaff, Ronald J; Skinner, John; Hart, Alister

    2016-06-01

    Failure to place an artificial hip in the optimal center of rotation results in poor hip function and costly complications. The aim of this study was to develop robust methodology to estimate hip center of rotation (hCoR) from preoperative computed tomography (CT) scans, using contralateral anatomy, in patients with unilateral diseased hips. Ten patients (five male, five female) with normal pelvic anatomy, and one patient with a unilateral dysplastic acetabulum were recruited from the London Implant Retrieval center image bank. 3D models of each pelvis were generated using commercial software. Two methods for estimation of hCoR were compared. Method 1 used a mirroring technique alone. Method 2 utilized mirroring and automatic alignment. Predicted versus actual hCoR co-ordinates were compared using intraclass correlation coefficients and paired T-tests. Both methods predicted hCoR with excellent agreement to original co-ordinates (>0.9) in all axes. Both techniques allowed prediction of the hCoR within ± 5 mm in all axes. Both techniques provided useful clinical information for planning acetabular reconstruction in patients with unilateral defects. Method 1 was less complex and is suitable for patients with developmental and degenerative pathologies. Method 2 may provide greater accuracy in a discrete group of patients with normal development prior to pathology (e.g., acetabular fractures). © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1077-1083, 2016. PMID:26630078

  6. Developmental Dislocation (Dysplasia) of the Hip (DDH)

    Science.gov (United States)

    .org Developmental Dislocation (Dysplasia) of the Hip (DDH) Page ( 1 ) The hip is a “ball-and-socket” joint. In a normal hip, the ball at the ... American Academy of Orthopaedic Surgeons. .org Developmental Dislocation (Dysplasia) of the Hip cont. • Family history of DDH (parents or siblings) • ...

  7. Hip complications following chemoradiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, P.J.; Sebag Montefiore, D.J.; Arnott, S.J. [Saint Bartholomew`s Hospital, London (United Kingdom)

    1995-12-01

    Chemoradiotherapy protocols are a recent development in the management of tumours where preservation of organ function is important. It is now recognized that such combined treatment may produce adverse effects below the accepted dose thresholds for either modality. This enhancement of toxicity is generally thought to reflect depletion of stem cells within the tissue concerned. We report four patients who have developed avascular necrosis or fractures of the hip following chemoradiotherapy for carcinoma of the vulva or anus. These complications developed after a radiation dose of 4500 cGy in 20 fractions. The possible role of cytotoxic agents in sensitizing bone to radiation damage is discussed, and a novel mechanism is proposed to account for this phenomenon. (author).

  8. Anterior hip pain.

    Science.gov (United States)

    O'Kane, J W

    1999-10-15

    Anterior hip pain is a common complaint with many possible causes. Apophyseal avulsion and slipped capital femoral epiphysis should not be overlooked in adolescents. Muscle and tendon strains are common in adults. Subsequent to accurate diagnosis, strains should improve with rest and directed conservative treatment. Osteoarthritis, which is diagnosed radiographically, generally occurs in middle-aged and older adults. Arthritis in younger adults should prompt consideration of an inflammatory cause. A possible femoral neck stress fracture should be evaluated urgently to prevent the potentially significant complications associated with displacement. Patients with osteitis pubis should be educated about the natural history of the condition and should undergo physical therapy to correct abnormal pelvic mechanics. "Sports hernias," nerve entrapments and labral pathologic conditions should be considered in athletic adults with characteristic presentations and chronic symptoms. Surgical intervention may allow resumption of pain-free athletic activity. PMID:10537384

  9. Traumatic injuries of the hip.

    LENUS (Irish Health Repository)

    Marshall, Nina

    2009-11-01

    Traumatic lesions of the hip in athletes may be clinically challenging because of the overlap in clinical presentation due to differing pathologies and the presence of multiple injuries. Imaging of the hip in the athlete has undergone a recent resurgence of interest and understanding related to the increasing accessibility and use of hip arthroscopy, which expands the treatment options available for intra-articular pathology. MR imaging and MR arthrography have a unique role in diagnosis of these pathologies, guiding the surgeon, arthroscopist, and referring clinician in their management of bony and soft tissue injury.

  10. Chronic infections in hip arthroplasties

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Thomsen, Reimar W; Søballe, Kjeld

    2012-01-01

    Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two-stage revisi......Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two......-stage revisions for chronic infection in hip arthroplasties....

  11. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... mild dysplasia with cystic changes and loss of joint space. No real significant osteophytes we’re going ... inclination to her hips and her slightly dysplastic joint; otherwise having excellent and relatively normal anatomy. Any ...

  12. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... Taperloc Microplasty stem and E-poly antioxidant-infused technology during a hip replacement through the anterior supine ... renewed interest at this time due to several advantages that it brings. The approach that is performed ...

  13. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... an anterior approach total hip replacement with the patient on a regular OR table supine. My name ... less invasive without being small incision surgery. Obese patients can be easier due to less distribution of ...

  14. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... about 36 cases, but that did not include five or six hip cadavers, many of which I ... I think that’s good. I think, you know, five to ten, you’re fairly comfortable with a ...

  15. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... don’t have a lot of subcutaneous adipose tissue in this layer in the front of their ... the hip and we’ll use the bipolar tissue sealing device. I know, Roger, you have used ...

  16. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... the benefits of the Taperloc Microplasty stem and E-poly antioxidant-infused technology during a hip replacement ... to your questions that you send in by e-mail. The e- mail button is at the ...

  17. Excess mortality following hip fracture

    DEFF Research Database (Denmark)

    Abrahamsen, B; van Staa, T; Ariely, R;

    2009-01-01

    Summary This systematic literature review has shown that patients experiencing hip fracture after low-impact trauma are at considerable excess risk for death compared with nonhip fracture/community control populations. The increased mortality risk may persist for several years thereafter......, highlighting the need for interventions to reduce this risk.Patients experiencing hip fracture after low-impact trauma are at considerable risk for subsequent osteoporotic fractures and premature death. We conducted a systematic review of the literature to identify all studies that reported unadjusted and...... excess mortality rates for hip fracture. Although a lack of consistent study design precluded any formal meta-analysis or pooled analysis of the data, we have shown that hip fracture is associated with excess mortality (over and above mortality rates in nonhip fracture/community control populations...

  18. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... means that I’m looking at using a Delta ceramic. So now we’re going to take ... out of bed and get to the commode. Delta ceramic hip, this is the next generation ceramic. ...

  19. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... we’re doing a right hip. She has mild dysplasia with cystic changes and loss of joint ... different. Yeah. But, you know, even with this mild dysplasia and slight anteversion. Yeah. The point here ...

  20. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... hip procedures. I would like to acknowledge the help and inspiration of Dr. Eric Dewitt, from Belgium, ... a little there as well, Roger. That will help us. I think these vessels are important to ...

  1. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... be. Yeah. There’s no bleeding you can’t control in this part of the hip. But occasionally ... on. My experience, these patients have full leg control in about 24 hours. Yeah. They can get ...

  2. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... of the hip and we’ll use the bipolar tissue sealing device. I know, Roger, you have ... Hurley that wants to know who makes the bipolar device. Okay. So we’re getting pretty close ...

  3. Getting your home ready - knee or hip surgery

    Science.gov (United States)

    ... Hip joint replacement Knee arthroscopy Knee joint replacement Knee microfracture surgery Patient Instructions ACL reconstruction - discharge Hip fracture - discharge Hip or knee replacement - after - what to ...

  4. Canine Hip Dysplasia: Breed Effects

    OpenAIRE

    Martin, S W; Kirby, K.; Pennock, P W

    1980-01-01

    This paper is a refinement of previous studies in that only suitably radiographed dogs were included in the data base. The rate of hip dysplasia varied widely by breed from five percent in siberian huskies to eighty-three percent in english bulldogs. There was a significant difference in the prevalence of dysplasia within at least two breeds; golden retrievers and old english sheepdogs. Physical size per se did not appear to be an important determinant of hip dysplasia.

  5. The hip in cerebral palsy.

    Science.gov (United States)

    Bleck, E E

    1980-01-01

    Orthopedic surgery can alleviate the hip flexion, adduction, and medial rotation deformities of the hip and improve the function and appearance of gait. To accomplish this, however, careful examination and prudence in the operative procedure to avoid overdoing and overcorrecting are important. Orthopedic surgery can prevent subluxation and dislocation of the hip before the age of seven years, and consequently repetitive radiographic examinations of the hip in children who have spastic paralysis of the hip musculature should be a routine procedure. Subluxation and dislocation of the hip, when established, can be successfully treated with orthopedic surgical procedures. Physicians must keep in mind that the spastic paralysis of cerebral palsy originates in the brain, and therefore the spasticity cannot be eliminated. The best that can be done is to weaken or remove some muscles as deforming forces and to achieve compromises for continued function. The goal should be optimal independence for the child and adolescent during development, and freedom from pain with deteriorating function due to degenerative arthritis in the adult. PMID:7360505

  6. Neonatal hip dysplasia: Differental diagnosis

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2010-01-01

    Full Text Available Introduction. Hip dysplasia is the elementary form of the developmental dysplasia of the hip (DDH. The diagnosis may be made by the ultrasound examination (types II a-, II b. Objective. The aim of the authors was to define the congenital structural neonatal hip dysplasia, and to differentiate hip hypoplasia, hip dysplasia and teratogenic anomalies. Methods. In all the cases, the uniform clinical and ultrasound tests were performed. All the patients were examined in the neonatal period of life (the first six weeks. The following clinical tests were used: Le Damany-Ortolany, Coleman-Barlow-Palmen and Weissman-Strinović. For the ultrasound examination, the Graph’s method was used. Results. The investigation was performed in the period 2007- 2008. 2,878 neonates were included. The distribution of the sonotypes, according to Graph, was as follows: Ia in 16.17%. Ib in 65.08%; IIa+ in 18.17%, IIc in 0.28%, IId in 0.19%; IIIa in 0.009%, IIIb in 0.02%; and IV in 0.01%. It was found that DDH was 8 times more frequent in girls; located more frequently at the left side than bilaterally. Conclusion. Hip sonoscreening has to be performed in all newborns in the first 72 hours. The suggested follow-up period is six weeks: for the diagnosis - the first three weeks, and for the prevention and treatment - all six weeks.

  7. Effects of different materials on stress distribution and biomechanics of bone interface of artificial hip joint%不同材料人工髋关节假体对骨界面应力分布及生物力学的影响

    Institute of Scientific and Technical Information of China (English)

    李宁远; 龚亚莉; 刘煊文; 周强

    2016-01-01

    BACKGROUND:During joint replacement, different materials of prosthesis can be used. Different prosthesis can produce different effects and the stress distribution of bone interface. OBJECTIVE:To explore the effects of different materials on the stress distribution and biomechanics of the bone interface of artificial hip joint. METHODS:The CT scan of the hip was carried out. The image data were saved in DICOM format and processed by MIMICS software. The 3D finite element model of the femur was obtained by ANSYS. A three dimensional finite element model of the femur was made with the material properties of the femur. Three kinds of different replacement prosthesis materials (Co Cr Mo aloy, titanium aloy and composite materials) were selected, and the specific requirements of the actual joint replacement were selected, and different types of prosthesis were designed in CAE software. In the STL format, the prosthesis model was imported into MIMICS, and the femur and prosthesis were assembled. The stress status of different prosthesis was analyzed, and the stress shielding rates of exterior and interior sides of middle and lower parts of the femur, right to and 30 mm below lesser trochanter and right to lesser trochanter of the proximal femur were calculated. RESULTS AND CONCLUSION:Through three-dimensional finite element analysis, a direct and accurate model of the femur and the three-dimensional model of the prosthesis were established. According to the actual situation, material assignment of the femoral three-dimensional finite element model was conducted to obtain the corresponding model. Thus, the properties of different materials of the femur were shown visualy. The femoral stress of cobalt chromium molybdenum aloy, titanium aloy, and composite material was simulated after replacement. Results found that the stress shielding rate can decrease in the middle and lower parts of the femur. After replacement, the femoral stress is higher than that of the intact femur

  8. Pathologic ligamentous constraint of the hip.

    Science.gov (United States)

    Crowninshield, R D; Johnston, R C; Brand, R A; Pedersen, D R

    1983-12-01

    A mathematic model of the hip capsule and lower extremity musculature was utilized to predict the forces present in the hip ligaments during locomotion. The results demonstrate principles and trends (rather than absolute results) in hip mechanics, the details of which are affected by the associated modeling assumptions. The active stretching of a hip joint capsule tightened by scarring or surgical transfer may appreciably increase the hip contact force. Capsular elements that prevent hip flexion and adduction play a major role in hip contact force exaggeration during common activities. The positive effect of maintaining the hip capsule to reduce total hip component dislocation contrasts with the potential negative effects of restricting joint motion and increasing the joint contact force. Increased joint loading due to capsular restriction may contribute to prosthetic component loosening. PMID:6641064

  9. Osteochondritis Dissecans of the Hip

    Energy Technology Data Exchange (ETDEWEB)

    Linden, B. [Hoeglands Hospital, Eksjoe (Sweden). Dept. of Orthopedic Surgery; Jonsson, K. [Univ. Hospital, Lund (Sweden). Center for Medical Imaging and Physiology; Redlund-Johnell, I. [Univ. Hospital, Malmoe (Sweden). Dept. of Diagnostic Radiology

    2003-03-01

    Purpose: To investigate the clinical and radiological characteristics of osteochondritis dissecans (OD) of the hip and the outcome of this condition after treatment. Material and Methods: Twelve male and 3 female patients with OD were retrospectively studied. Six patients had a history of Legg-Calve-Perthes disease (LCPD) and among them 2 also had had a trauma to the hip. A further 5 had had trauma and 1 a developmental dislocation of the hip (DDH). The remaining 3 patients had no history of previous hip disease or trauma. All patients were examined with plain radiography, 7 with MR, 3 with CT and 2 with hip arthrography. Results: All OD lesions were detected at plain radiography, and most of them were located near the fovea. At MR the lesions had low signal intensity at T1-weighted sequences, and 6/7 had edema or fluid collection in or adjacent to the lesion on T2-weighted sequences. The early treatment in 7 patients was surgery, 2 had had conservative treatment and 6 no treatment. At follow-up 12 years after radiological diagnosis, 5 patients had hip arthrosis, 4 of whom were treated with arthroplasty. All but 3 had reduced hip rotation and all but 2 (with arthroplasty) had load pain. Three of the patients with earlier surgery had not developed arthrosis. Conclusions: OD lesions are usually well seen with plain radiography. There is a great risk of developing early arthrosis and it seems that early surgery is connected with arthrosis development. Thus only symptomatic treatment is recommended.

  10. Osteochondritis Dissecans of the Hip

    International Nuclear Information System (INIS)

    Purpose: To investigate the clinical and radiological characteristics of osteochondritis dissecans (OD) of the hip and the outcome of this condition after treatment. Material and Methods: Twelve male and 3 female patients with OD were retrospectively studied. Six patients had a history of Legg-Calve-Perthes disease (LCPD) and among them 2 also had had a trauma to the hip. A further 5 had had trauma and 1 a developmental dislocation of the hip (DDH). The remaining 3 patients had no history of previous hip disease or trauma. All patients were examined with plain radiography, 7 with MR, 3 with CT and 2 with hip arthrography. Results: All OD lesions were detected at plain radiography, and most of them were located near the fovea. At MR the lesions had low signal intensity at T1-weighted sequences, and 6/7 had edema or fluid collection in or adjacent to the lesion on T2-weighted sequences. The early treatment in 7 patients was surgery, 2 had had conservative treatment and 6 no treatment. At follow-up 12 years after radiological diagnosis, 5 patients had hip arthrosis, 4 of whom were treated with arthroplasty. All but 3 had reduced hip rotation and all but 2 (with arthroplasty) had load pain. Three of the patients with earlier surgery had not developed arthrosis. Conclusions: OD lesions are usually well seen with plain radiography. There is a great risk of developing early arthrosis and it seems that early surgery is connected with arthrosis development. Thus only symptomatic treatment is recommended

  11. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... did you see there, is to minimize the bacteria on the skin. The irrigation of the wound, ... very much. So hip resurfacing. Hip resurfacing is similar but also different from hip -- standard hip replacement. ...

  12. Emerging topics on the hip: Ligamentum teres and hip microinstability

    International Nuclear Information System (INIS)

    Microinstability and ligament teres lesions are emergent topics on the hip pathology. These entities are an increasingly recognized cause of persistent hip pain and should be considered in the differential diagnosis of the patient with hip pain. Conventional (non-arthrographic) CT and MR have a very limited role in the evaluation of these entities. CTa and MRa have emerged as the modalities of choice for pre-operative imaging of ligamentum teres injuries and microinstability. To date, pre-operative imaging detection of these pathologies is not widespread but with appropriate imaging and a high index of suspicion, preoperative detection should improve. This article discusses current concepts regarding anatomy, biomechanics, clinical findings, diagnosis and treatment of ligament teres lesions and microinstability.

  13. Emerging topics on the hip: Ligamentum teres and hip microinstability

    Energy Technology Data Exchange (ETDEWEB)

    Cerezal, Luis, E-mail: lcerezal@gmail.com [Diagnóstico Médico Cantabria, C/Castilla 6, 39002 Santander (Spain); Arnaiz, Javier; Canga, Ana; Piedra, Tatiana [Valdecilla University Hospital, 39011 Santander (Spain); Altónaga, José R. [Leon University, 24071 Leon (Spain); Munafo, Ricardo [CETEA, Buenos Aires (Argentina); Pérez-Carro, Luis [Valdecilla University Hospital, 39011 Santander (Spain)

    2012-12-15

    Microinstability and ligament teres lesions are emergent topics on the hip pathology. These entities are an increasingly recognized cause of persistent hip pain and should be considered in the differential diagnosis of the patient with hip pain. Conventional (non-arthrographic) CT and MR have a very limited role in the evaluation of these entities. CTa and MRa have emerged as the modalities of choice for pre-operative imaging of ligamentum teres injuries and microinstability. To date, pre-operative imaging detection of these pathologies is not widespread but with appropriate imaging and a high index of suspicion, preoperative detection should improve. This article discusses current concepts regarding anatomy, biomechanics, clinical findings, diagnosis and treatment of ligament teres lesions and microinstability.

  14. Transient Osteoporosis of the Hip

    Directory of Open Access Journals (Sweden)

    Farideh Shahandeh

    2009-01-01

    Full Text Available   "nTransient osteoporosis of the hip as originally described in women, almost exclusively involved the left hip with the third trimester of pregnancy. It is now recognized as actually being more common in middle-aged men and affecting either hip. "nSymptoms include severe hip pain and decreased range of motion that resolves spontaneously in 6 to 12 months. The etiology is poorly understood, and the disease has been associated with a type of reflex sympathetic dystrophy syndrome. It may be migratory, with subsequent involvement of the opposite hip on an adjacent joint. Radiological changes may simulate indolent infection, osteonecrosis or infiltrative neoplasm. The underlying pathologic condition appears to be bone marrow reaction or edema. Current terminology may refer to this entity as transient bone marrow edema syndrome. Radiographs usually show osteopenia, and bone scan reveals intense activity locally within the femoral head – unlike A.V.N which often displays central photopenia. MRI demonstrates diffuse marrow abnormalities that usually extend from the subchondral femoral head to the inter trochanteric and sub trochanteric regions. There is low signal intensity on T1 weighted MR images and high signal intensity on T2 weighted sequences. The MRI changes reflect the nonspecific marrow reaction or edema that is present. Focal osteoporotic bone marrow defects in the subchondral region or subtle femoral head flattening should be searched for diligently on MR images. Unlike the case with A.V.N. , these defects are usually absent in transient osteoporosis.   

  15. Traumatic hip dislocations in children

    International Nuclear Information System (INIS)

    Objectives: To evaluate clinical features, treatment and relationship to the time period between dislocation, reduction and early complications of traumatic dislocation of hip in children. Methods: Case series conducted at Jinnah Post Graduate Medical Centre Karachi from July 2005 to August 2009. Children with traumatic hip dislocation up to fifteen years of age who presented in last four years were included in this study. Their clinical information, etiology, associated injuries, duration, method of reduction and early complications are evaluated through emergency room proforma and indoor record. Follow up of patient was updated in outpatient department. Results: We had eight patients, six boys and two girls. Youngest 2.4 years and eldest was 12 years with mean age of 6.2 +- 3.8 years. All presented with posterior hip dislocation. Etiology was road traffic accident in two and history of fall in remaining six patients. Average duration of time between dislocation and reduction was 19 hours range 3-72 hours. Dislocated hips were reduced under General Anaesthesia in two patients and under sedation analgesia in six patients. No complications were noted in eight cases with mean 18.75 +- 13.23 months follows up. Conclusion: Traumatic hip dislocation in children is not rare. Slight trauma causes dislocation in younger age and immediate closed reduction and Immobilization reduces complications. (author

  16. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... uncemented prosthesis. 888.3360 Section 888.3360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be...

  17. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3370 Section 888.3370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular metal cemented prosthesis is a device intended to be implanted to replace a portion of the hip...

  18. 21 CFR 888.3400 - Hip joint femoral (hemi-hip) metallic resurfacing prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3400 Section 888.3400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... femoral (hemi-hip) metallic resurfacing prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic resurfacing prosthesis is a device intended to be implanted to replace a portion of the hip...

  19. Exercise therapy may postpone total hip replacement surgery in patients with hip osteoarthritis

    DEFF Research Database (Denmark)

    Svege, Ida; Nordsletten, Lars; Fernandes, Linda; Risberg, May Arna

    2015-01-01

    Exercise treatment is recommended for all patients with hip osteoarthritis (OA), but its effect on the long-term need for total hip replacement (THR) is unknown.......Exercise treatment is recommended for all patients with hip osteoarthritis (OA), but its effect on the long-term need for total hip replacement (THR) is unknown....

  20. Aplicaciones en las Ciencias de lo artificial

    OpenAIRE

    Sáez Vacas, Fernando

    1980-01-01

    En esta ponencia se restringen las ciencias de lo artificial a los objetos o artefactos compuestos por elementos no vivientes o en los que esta característica se muestra con complejidad controlada. Si se hablase genéricamente de máquinas en lugar de artefactos, sería por referencia a máquinas artificiales, aún cuando en el diseño de éstas se intentase imitar las propiedades de las máquinas naturales (Atlan,79). Es ésta una Hipótesis para delimitar un terreno de trabajo, delimitación que bi...

  1. Artificial Economy

    Directory of Open Access Journals (Sweden)

    Alexandru JIVAN

    2011-08-01

    Full Text Available This paper proposes to eliminate, a routine in the economic thinking, claimed to be responsible for the negative essence of economic developments, from the point of view, of the ecological implications (employment in the planetary ecosystem. The methodological foundations start from the natural origins of the functionality of the human economic society according to the originary physiocrat liberalism, and from specific natural characteristics of the humankind. This paper begins with a comment-analysis of the difference between natural and artificial within the economy, and then explains some of the most serious diversions from the natural essence of economic liberalism. It shall be explained the original (heterodox interpretation of the Classical political economy (economics, by making calls to the Romanian economic thinking from aggravating past century. Highlighting the destructive impact of the economy - which, under the invoked doctrines, we call unnatural - allows an intuitive presentation of a logical extension of Marshall's market price, based on previous research. Besides the doctrinal arguments presented, the economic realities inventoried along the way (major deficiencies and effects, determined demonstrate the validity of the hypothesis of the unnatural character and therefore necessarily to be corrected, of the concept and of the mechanisms of the current economy.The results of this paper consist of original heterodox methodspresented, intuitive or developed that can be found conclusively within the key proposals for education and regulation.

  2. Developmental hip dysplasia in adolescence

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2009-01-01

    Full Text Available The authors define adolescence and developmental dysplasia of the hip (DDH. Special attention is paid to pathological findings characteristic of DDH in adolescence (unrecognized and untreated DDH; treated DDH, but non-terminated treatment; DDH diagnosed with delay, inadequately treated, with complications. The authors emphasise that DDH treatment has to be successfully terminated well before the adolescence; possibilities are explained on management modes at the time of adolescence, and possible persons guilty for the persistence of later hip problems are indicated. Based on the authors' experience and having in mind all surgical possibilities for the treatment (pelvic osteotomies, femoral osteotomies, trochanteroplasties, leg length equalization procedures the authors propose treatment protocols. The intention is to provide better treatment results and to prevent secondary hip arthrosis. Furthermore, how to improve the struggle against DDH is suggested.

  3. Cementless Hydroxyapatite Coated Hip Prostheses

    Directory of Open Access Journals (Sweden)

    Antonio Herrera

    2015-01-01

    Full Text Available More than twenty years ago, hydroxyapatite (HA, calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality.

  4. MRI of the hip joint

    International Nuclear Information System (INIS)

    Magnetic resonance imaging (MRI) is performed to diagnose many pathologic conditions affecting the hip joint. Either conventional MRI (without contrast enhancement of the joint cavity) or MR arthrography is used to detect and most accurately differentiate hip joint pathologies. Conventional MRI is performed in cases of bone marrow edema, necrosis, arthrosis and especially the so-called ''activated arthrosis'', as well as in inflammatory and tumorous entities. MR arthography, which has only recently become available for use, is excellently suited for diagnosing lesions of the acetabular labrum, cartilage lesions, and free articular bodies. This article provides an overview about MRI characteristics and their accuracy of hip joint diseases and the impact on the therapeutic procedure. (orig.)

  5. Computed tomography in abnormalities of the hip

    International Nuclear Information System (INIS)

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip join can be measured by means of computed tomography. (Auth.)

  6. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  7. TREATMENT OF NEUROLOGICAL CONGENITAL HIP LUXATION

    OpenAIRE

    Iulian ICLEANU; Mariana CORDUN

    2015-01-01

    Congenital hip luxation is a disorder which evolves in time. Teratological hip dislocation is a distinct form of hip luxation, which usually appears with other disorders. These hips are dislocated before birth. In this thesis we will try to elaborate a recovery program, through physical exercises, which will help us realize our treatment objectives: diminishing articular stiffness, increasing articular mobility, increasing muscle strength, recalibration of agonist and antagonist balances and ...

  8. Hip arthroscopy. The supine position.

    Science.gov (United States)

    Byrd, J W

    2001-10-01

    Hip arthroscopy is an effective technique. It can be performed successfully either supine or in the lateral position, but there appear to be modest advantages of the supine approach. Arthroscopy offers a less invasive alternative to arthrotomy for traditionally recognized forms of hip pathology, such as loose bodies or impinging osteophytes. Arthroscopy also offers a method of treatment for many conditions (including labral tears, acute articular injuries, and damage to the ligamentum teres) that previously went unrecognized and untreated. In the past, these patients were simply resigned to living within the constraints of their symptoms. Several dictums about hip arthroscopy must be acknowledged. First, the key to a successful outcome lies in proper patient selection. A technically well-executed procedure will fail when performed for the wrong reason, or when the outcome fails to meet the patient's expectations. Second, the patient must be properly positioned for the procedure to go well. Poor positioning will assure a difficult procedure. Third, simply gaining access to the hip joint is not an outstanding technical accomplishment. The paramount issue is accessing the joint in as atraumatic a fashion as possible. Due to its constrained architecture and dense soft tissue envelope, the potential for inadvertent iatrogenic scope trauma is significant and, perhaps unavoidable to some extent. Therefore, every reasonable step should be taken to keep this concern to a minimum. Perform the procedure as carefully as possible and be certain that it is being performed for the right reason. After accessing the joint, the techniques of operative arthroscopy for the hip employ existing strategies established in other joints. Because of the restraints imposed by the hip, however, technical deficiencies may be more apparent. PMID:11675882

  9. SENILE OSTEOPOROSIS AND HIP FRACTURE

    Institute of Scientific and Technical Information of China (English)

    戴力扬

    1995-01-01

    A randomized block design was used to compare the Singh index, the cortical index of the femoral neck and the lateral cortical width of the femur of a group of patients with femoral neck fracture, a group with intertrochanterie fracture, and a normal contrrol group among a total of 102 postmenopausal women. The three irtdiees in fracture grotlp were very significantly (P<0. 01) or significantly (P<0. 05) different from those in the normal control subjects. The importance of osteopomosis in hip fracture of the aged is con-firmed. Radiographic measurement of bone mass was found to have some predictive value for the risk of hip fracture.

  10. Hip-Hop and the Academic Canon

    Science.gov (United States)

    Abe, Daudi

    2009-01-01

    Over the last 30 years, the hip-hop movement has risen from the margins to become the preeminent force in US popular culture. In more recent times academics have begun to harness the power of hip-hop culture and use it as a means of infusing transformative knowledge into the mainstream academic discourse. On many college campuses, hip-hop's…

  11. Ultrasonography of the painful hip in childhood

    NARCIS (Netherlands)

    S.G.F. Robben (Simon)

    1999-01-01

    textabstractThere are many diseases in childhood that affect the hip joint. Some diseases are systemic in origin and initially may present themselves as hip disorders, such as rheumatoid arthritis. other diseases are localized specifically in the hip joint, such as transient synovitis and Perthes' d

  12. Hip osteoarthritis and dysplasia in Chinese men.

    OpenAIRE

    Lau, E. M.; Lin, F.; Lam, D; Silman, A.; Croft, P.

    1995-01-01

    OBJECTIVE--To estimate the prevalence of hip osteoarthritis (OA hip) and hip dysplasia in a sample of Hong Kong men who were unselected with respect to hip symptoms. METHODS--The postmicturition films of 999 men aged 60-75 years, consecutive attenders for intravenous urography between 1987 and 1990 at a regional hospital, were reviewed. OA hip was diagnosed as the occurrence of two or more features of OA using a modified version of the Kellgren and Lawrence scale, or a minimal joint space of ...

  13. Poor fixation of the Mittelmeier hip prosthesis

    International Nuclear Information System (INIS)

    We have evaluated 30 Mittelmeier hips on an average 3.3 years after the operation. Seven hips had been revised because of severe pain and mechanical loosening and one because of fracture of the threaded ceramic cup. Only five of the remaining 22 hips were asymptomatic. There was radiographic migration of the acetabular and femoral components in more than one third of the hips and increased scintimetric values around the femoral component in all but two hips. Unfavorable design of the Mittelmeier prosthesis may be an important etiologic factor contributing to poor component fixation and inferior clinical results. (author)

  14. [Congenital hip dysplasia, screening and therapy].

    Science.gov (United States)

    Kolb, A; Windhager, R; Chiari, C

    2015-11-01

    Congenital hip dysplasia and hip dislocation are relatively common pathological conditions of the musculoskeletal system in infants. An early and certain diagnosis can now be achieved by sonographic hip screening within the framework of screening examination programs. This early diagnostic procedure in infants is essential particularly for a conservative treatment strategy. Therefore, apart from possessing in-depth knowledge, training of the examiner in specialist courses is of central importance. This article presents an overview of the entity of congenital hip dysplasia and hip dislocation, the diagnostics and treatment with special emphasis on recent developments. PMID:26489825

  15. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... tonight. Dr. Berend, are you ready? Yes, sir. Let’s go. Great. Well, thanks, Roger, for that introduction, and ... got the left image now on the screen. Let’s go to the operative hip. Save that. Flip it ...

  16. Hip-Hop Pop Art

    Science.gov (United States)

    Talley, Clarence, Sr.

    2011-01-01

    Art has a way of helping students better understand and appreciate the world around them, particularly the things that are most important to them. Hip hop is one of those generational genres that capture the attention of young students like few other things do. Drawing on this genre to get students to create art is an excellent way to demonstrate…

  17. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... during a hip replacement through the anterior supine intramuscular approach. “OR-Live,” the vision of improving health. ... the approach are operating through an internervous and intramuscular anatomic interval. It’s not necessary to detach any ...

  18. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... of the Taperloc Microplasty stem and E-poly antioxidant-infused technology during a hip replacement through the ... a little diaper so we’re seeing less skin and more -- Here we go. Here’s what we’ ...

  19. Fracture After Total Hip Replacement

    Science.gov (United States)

    ... Della Valle CJ, Haidukewych GJ, Callaghan JJ: Periprosthetic fractures of the hip and knee: a problem on the rise but better solutions. ... weeks in a skilled nursing facility or a rehabilitation center in order to improve your ... can be serious. The most common complications include: • ...

  20. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... and I’m able to use a modern generation highly cross-linked, highly eradiated, and then vitamin ... commode. Delta ceramic hip, this is the next generation ceramic. 32 enlarger, there’s been no reported fractures. ...

  1. Imaging of hip joint arthroplasty

    International Nuclear Information System (INIS)

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.)

  2. Hip Imaging in Athletes: Sports Imaging Series.

    Science.gov (United States)

    Agten, Christoph A; Sutter, Reto; Buck, Florian M; Pfirrmann, Christian W A

    2016-08-01

    Hip or groin pain in athletes is common and clinical presentation is often nonspecific. Imaging is a very important diagnostic step in the work-up of athletes with hip pain. This review article provides an overview on hip biomechanics and discusses strategies for hip imaging modalities such as radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging (MR arthrography and traction MR arthrography). The authors explain current concepts of femoroacetabular impingement and the problem of high prevalence of cam- and pincer-type morphology in asymptomatic persons. With the main focus on MR imaging, the authors present abnormalities of the hip joint and the surrounding soft tissues that can occur in athletes: intraarticular and extraarticular hip impingement syndromes, labral and cartilage disease, microinstability of the hip, myotendinous injuries, and athletic pubalgia. (©) RSNA, 2016. PMID:27429142

  3. Techniques and results for open hip preservation

    Directory of Open Access Journals (Sweden)

    David eLevy

    2015-12-01

    Full Text Available While hip arthroscopy grows in popularity, there are still many circumstances under which open hip preservation is most appropriately indicated. This article specifically reviews open hip preservation procedures for a variety of hip conditions. Femoral acetabular impingement may be corrected using an open surgical hip dislocation. Acetabular dysplasia may be corrected using a periacetabular osteotomy. Acetabular protrusio may require surgical hip dislocation with rim trimming and a possible valgus intertrochanteric osteotomy. Legg-Calve ́-Perthes disease produces complex deformities that may be better served with osteotomies of the proximal femur and/ or acetabulum. Chronic slipped capital femoral epiphysis (SCFE may also benefit from a surgical hip dislocation and/or proximal femoral osteotomy.

  4. Eccentric hip abductor weakness in patients with symptomatic external snapping hip

    DEFF Research Database (Denmark)

    Jacobsen, Julie Sandell; Thorborg, Kristian; Søballe, K; Ulrich-Vinther, M

    2012-01-01

    Symptomatic external snapping hip can be a long-standing condition affecting physical function in younger people between 15-40 years. Gluteal weakness has been suggested to be associated with the condition. The aim of this study was to investigate whether eccentric hip abduction strength is...... decreased in patients with external snapping hip compared with healthy matched controls, and to examine isometric hip abduction, adduction, extension, flexion, internal rotation, and external rotation in patients with external snapping hip and matched controls. Thirteen patients with external snapping hip....... Eccentric hip abduction strength was 16% lower in patients with external snapping hip compared with healthy matched controls (1.50± 0.47 Nm/kg versus 1.82 ± 0.48 Nm/kg, P = 0.01). No other strength differences were measured between patients and controls (P > 0.05). Eccentric hip abductor weakness was...

  5. Hip dysplasia: a significant risk factor for the development of hip osteoarthritis. A cross-sectional survey

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig

    2005-01-01

    joint space width (JSW) /=60 yr of age. Of factors entered into logistic regression analyses, only age (P LT 0.001 for right hips and P LT 0.001 for left hips) and hip dysplasia (P LT 0.001 for right hips and P = 0.004 for left hips) were significantly associated with hip OA prevalence in women. In men......, only hip dysplasia was associated with hip OA prevalence, P LT 0.001 in right hips and P = 0.001 in left hips. CONCLUSIONS: Of the individual risk factors investigated in this study, only age and hip dysplasia were associated with the development of hip osteoarthritis.......OBJECTIVES: The aim of this cross-sectional survey of 2232 women and 1336 men (age range 20-91 yr) was to investigate individual risk factors for hip joint osteoarthritis (OA). METHODS: Standardized, weight-bearing pelvic radiographs were evaluated. Radiological hip joint OA was defined as minimum...

  6. Hip dysplasia: a significant risk factor for the development of hip osteoarthritis. A cross-sectional survey

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig

    2005-01-01

    OBJECTIVES: The aim of this cross-sectional survey of 2232 women and 1336 men (age range 20-91 yr) was to investigate individual risk factors for hip joint osteoarthritis (OA). METHODS: Standardized, weight-bearing pelvic radiographs were evaluated. Radiological hip joint OA was defined as minimum...... joint space width (JSW) /=60 yr of age. Of factors entered into logistic regression analyses, only age (P LT 0.001 for right hips and P LT 0.001 for left hips) and hip dysplasia (P LT 0.001 for right hips and P = 0.004 for left hips) were significantly associated with hip OA prevalence in women. In men......, only hip dysplasia was associated with hip OA prevalence, P LT 0.001 in right hips and P = 0.001 in left hips. CONCLUSIONS: Of the individual risk factors investigated in this study, only age and hip dysplasia were associated with the development of hip osteoarthritis....

  7. Economic viability of geriatric hip fracture centers.

    Science.gov (United States)

    Clement, R Carter; Ahn, Jaimo; Mehta, Samir; Bernstein, Joseph

    2013-12-01

    Management of geriatric hip fractures in a protocol-driven center can improve outcomes and reduce costs. Nonetheless, this approach has not spread as broadly as the effectiveness data would imply. One possible explanation is that operating such a center is not perceived as financially worthwhile. To assess the economic viability of dedicated hip fracture centers, the authors built a financial model to estimate profit as a function of costs, reimbursement, and patient volume in 3 settings: an average US hip fracture program, a highly efficient center, and an academic hospital without a specific hip fracture program. Results were tested with sensitivity analysis. A local market analysis was conducted to assess the feasibility of supporting profitable hip fracture centers. The results demonstrate that hip fracture treatment only becomes profitable when the annual caseload exceeds approximately 72, assuming costs characteristic of a typical US hip fracture program. The threshold of profitability is 49 cases per year for high-efficiency hip fracture centers and 151 for the urban academic hospital under review. The largest determinant of profit is reimbursement, followed by costs and volume. In the authors’ home market, 168 hospitals offer hip fracture care, yet 85% fall below the 72-case threshold. Hip fracture centers can be highly profitable through low costs and, especially, high revenues. However, most hospitals likely lose money by offering hip fracture care due to inadequate volume. Thus, both large and small facilities would benefit financially from the consolidation of hip fracture care at dedicated hip fracture centers. Typical US cities have adequate volume to support several such centers. PMID:24579222

  8. Cover Story: The Miseducation of Hip-Hop.

    Science.gov (United States)

    Evelyn, Jamilah

    2000-01-01

    Some higher education officials believe that hip-hop music is eating away at the morals, and ultimately the classroom experience, of today's college students. Discusses why the gap exists between student and faculty attitudes toward hip-hop, how hip-hop music represents blackness, how people perceive hip-hop youth, the positive side of hip-hop,…

  9. Artificial weathering of granite

    Directory of Open Access Journals (Sweden)

    Silva Hermo, B.

    2008-06-01

    Full Text Available This article summarizes a series of artificial weathering tests run on granite designed to: simulate the action of weathering agents on buildings and identify the underlying mechanisms, determine the salt resistance of different types of rock; evaluate consolidation and water-repellent treatment durability; and confirm hypotheses about the origin of salts such as gypsum that are often found in granite buildings. Salt crystallization tests were also conducted, using sodium chloride, sodium sulphate, calcium sulphate and seawater solutions. One of these tests was conducted in a chamber specifically designed to simulate salt spray weathering and another in an SO2 chamber to ascertain whether granite is subject to sulphation. The test results are analyzed and discussed, along with the shortcomings of each type of trial as a method for simulating the decay observed in monuments. The effect of factors such as wet-dry conditions, type of saline solution and the position of the planes of weakness on the type of decay is also addressed.En este trabajo se hace una síntesis de varios ensayos de alteración artificial realizados con rocas graníticas. Estos ensayos tenían distintos objetivos: reproducir las formas de alteración encontradas en los edificios para llegar a conocer los mecanismos que las generan, determinar la resistencia de las diferentes rocas a la acción de las sales, evaluar la durabilidad de tratamientos de consolidación e hidrofugación y constatar hipótesis acerca del origen de algunas sales, como el yeso, que aparecen frecuentemente en edificios graníticos. En los ensayos de cristalización de sales se utilizaron disoluciones de cloruro de sodio, sulfato de sodio, sulfato de calcio y agua de mar. Uno de estos ensayos se llevó a cabo en una cámara especialmente diseñada para reproducir la alteración por aerosol marino y otro se realizó en una cámara de SO2, con el objeto de comprobar si en rocas graníticas se puede producir

  10. Measurement outcomes from hip simulators.

    Science.gov (United States)

    de Villiers, Danielle; Shelton, Julia C

    2016-05-01

    Simulation of wear in total hip replacements has been recognised as an important factor in determining the likelihood of clinical success. However, accurate measurement of wear can be problematic with factors such as number and morphology of wear particles produced as well as ion release proving more important in the biological response to hip replacements than wear volume or wear rate alone. In this study, hard-on-hard (CoCr alloy, AgCrN coating) and hard-on-soft (CoCr alloy and CrN coating on vitamin E blended highly cross-linked polyethylene) bearing combinations were tested in an orbital hip simulator under standard and some adverse conditions. Gravimetric wear rates were determined for all bearings, with cobalt and where applicable, silver release determined throughout testing. Isolation of wear particles from the lubricating fluid was used to determine the influence of different bearing combinations and wear conditions on particle morphology. It was found that cobalt and silver could be measured in the lubricating fluid even when volumetric wear was not detectable. In hard-on-hard bearings, Pearson's correlation of 0.98 was established between metal release into the lubricating fluid and wear volume. In hard-on-soft bearings, coating the head did not influence the polyethylene wear rates measured under standard conditions but did influence the cobalt release; the diameter influenced both polyethylene wear and cobalt release, and the introduction of adverse testing generated smaller polyethylene particles. While hip simulators can be useful to assess the wear performance of a new material or design, measurement of other outcomes may yield greater insight into the clinical behaviour of the bearings in vivo. PMID:26888886

  11. Hip painful prosthesis: surgical view

    OpenAIRE

    SPINARELLI, ANTONIO; Patella, Vittorio; Conserva, Vito; Vicenti, Giovanni; Pesce, Vito; Patella, Silvio

    2011-01-01

    Painful hip prosthesis is the most feared immediate and remote complication of a primary implant and usually represents the failure of one or more therapeutic moments. In cases of aseptic implant failure, the causes invoked may be represented by an incorrect indication, the quality of materials, local and general condition of the patient and especially from a bad joint biomechanics. In cases of septic loosening, however, the cause of failure to be found in the location of pathogens within the...

  12. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain

    DEFF Research Database (Denmark)

    Rafn, Bolette S; Tang, Lars; Nielsen, Peter Martin;

    2016-01-01

    OBJECTIVE: To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. DESIGN: Cross-sectional study. SETTING: Clinical assessments at Sports Orthopaedic Research...... Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. PARTICIPANTS: Twenty-four male soccer players with unilateral long-standing hip and groin pain. INTERVENTIONS: The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion...... strength (Spearman rho = -0.44, P = 0.016). CONCLUSIONS: Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain....

  13. Artificial Inteligence and Law

    OpenAIRE

    Fuková, Kateřina

    2012-01-01

    Submitted diploma work Artificial Intelligence and Law deals with the rule of law and its position in the process of new advanced technologies in computer cybernetics and further scientific disciplines related with artificial intelligence and its creation. The first part of the work introduces the history of the first imagines about artificial intelligence and concerns with its birth. This chapter presents main theoretical knowledge and hypotheses defined artificial intelligence and progre...

  14. Artificial Skin in Robotics

    OpenAIRE

    Strohmayr, Michael

    2012-01-01

    Artificial Skin - A comprehensive interface for system-environment interaction - This thesis investigates a multifunctional artificial skin as touch sensitive whole-body cover for robotic systems. To further the evolution from tactile sensors to an implementable artificial skin a general concept for the design process is derived. A standard test procedure is proposed to evaluate the performance. The artificial skin contributes to a safe and intuitive physical human robot interaction.

  15. Influence of hip dysplasia on the development of osteoarthritis of the hip

    OpenAIRE

    Lievense, Annet; Bierma-zeinstra, Sita; Verhagen, Arianne; Verhaar, JAN; Koes, Bart

    2004-01-01

    textabstractBACKGROUND: It has been suggested that in some patients with primary hip osteoarthritis (OA), the disease occurs as a consequence of acetabular dysplasia or hip dysplasia (HD). OBJECTIVE: To carry out a systematic review to investigate the association between acetabular dysplasia and hip OA. METHODS: A database search of Medline, Embase, and the Cochrane library was carried out, and articles that aimed at studying the relationship between HD and hip OA were identified. The methodo...

  16. Resurfacing total hip replacement–a therapeutical approach in postmenopausal women with osteoporosis and hip arthrosis

    OpenAIRE

    Popescu, D.; Ene, R; Cirstoiu, C

    2011-01-01

    Aim: Patients with incipient hip arthrosis may benefit from a relatively new therapeutical approach using resurfacing total hip replacement, but in those with associated osteoporosis, this type of surgical intervention is contraindicated, given the poor quality of osteoporotic bones. We assessed the efficacy of the antiosteoporotic pharmacological therapy to improve bone quality and bone strength in postmenopausal women diagnosed with hip arthrosis and osteoporosis thus facilitating the hip s...

  17. Trusted Hosts in Host Identity Protocol (HIP)

    OpenAIRE

    K.C., Amir

    2012-01-01

    The goal of the project was to study the possibilities to establish trusted hosts in Host Identity Protocol (HIP) and implement certificate handling in HIP packets. The time complexity and performance while using certificates in HIP packets was also measured. The research project was carried out at Arcada University of Applied Sciences in collaboration with Helsinki University. The project aimed to implement standard x.509 certification of the public key used as HI (Host Identity) to deri...

  18. Hip and Spine in Cerebral Palsy

    OpenAIRE

    Persson-Bunke, Måns

    2015-01-01

    Abstract Background: Children with cerebral palsy (CP) have an increased risk of scoliosis, contractures including windswept hip deformity (WS), and hip dislocation. In 1994, a follow-up program and registry for children and adolescents with CP (CPUP) was initiated in Sweden to allow the early detection and prevention of hip dislocations and other musculoskeletal deformities. Purpose: To analyze the prevalence of scoliosis and WS in children with CP and to study the effect of CPUP. To e...

  19. Hip fractures. Epidemiology, risk factors, falls, energy absorption, hip protectors, and prevention

    DEFF Research Database (Denmark)

    Lauritzen, J B

    1997-01-01

    on the hip. Women with hip fractures have a lower body weight compared with controls, and they may also have less soft tissue covering the hip even when adjusted for body mass index, indicating a more android body habitus. Experimental studies show that the passive energy absorption in soft tissue...

  20. COMPLEX FUNCTIONAL ASSESSMENT OF THE HIP JOINT.

    Directory of Open Access Journals (Sweden)

    Maya S. Krastanova

    2015-09-01

    Full Text Available Introduction: In relation to the study reporting the effects of applying phased complex rehabilitation in patients with total hip arthroplasty, it has been concluded that the everyday clinical practice in Bulgaria does not apply complex examination, giving an objective picture about the extent of functional status of patients with trauma and diseases of the hip. Aim: The main goal of this report is to present a test which incorporates all known and routine research and in which the total number of points determines the functional status of patients with trauma and diseases of the hip. Material and Methods: Based on the Hip dysfunction and Osteoarthritis Outcome Score, the Harris Hip Score modified test, scale D’Aubigne and Postel and Iowa’s test for complex functional evaluation of the hip joint, we have developed a test including information about the degree of pain; goniometry and manual muscle testing of the hip; locomotor test – type of gait and adjuvants; test for Daily Activities of Life. The test has been developed on the basis of expert assessment by doctors and physiotherapists of the proposed indicators for evaluation and determination of the weighting factors’ contribution to the general condition of the patient. Conclusion: The developed and tested method of complex functional assessment of the hip joint enables our colleagues, dealing with trauma and diseases of the hip, to use it in various research and scientific projects, as well as in general medical practice.

  1. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... the femoral head which then leads to avascular necrosis of the hip. Just like the minimally invasive ... the hip and not rheumatoid arthritis or avascular necrosis, and who understand that the hip resurfacing is ...

  2. Surgical hip dislocation for treatment of cam femoroacetabular impingement

    Directory of Open Access Journals (Sweden)

    Milind M Chaudhary

    2015-01-01

    Conclusion: Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term.

  3. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... that are available for patients suffering from hip arthritis that we do here at Thomas Jefferson University ... or ceramic. But, not every patient who has arthritis of their hip needs a hip replacement. There ...

  4. The association between hip fracture and hip osteoarthritis: A case-control study

    Directory of Open Access Journals (Sweden)

    Englund Martin

    2010-11-01

    Full Text Available Abstract Background There have been reports both supporting and refuting an inverse relationship between hip fracture and hip osteoarthritis (OA. We explore this relationship using a case-control study design. Methods Exclusion criteria were previous hip fracture (same side or contralateral side, age younger than 60 years, foreign nationality, pathological fracture, rheumatoid arthritis and cases were radiographic examinations were not found in the archives. We studied all subjects with hip fracture that remained after the exclusion process that were treated at Akureyri University Hospital, Iceland 1990-2008, n = 562 (74% women. Hip fracture cases were compared with a cohort of subjects with colon radiographs, n = 803 (54% women to determine expected population prevalence of hip OA. Presence of radiographic hip OA was defined as a minimum joint space of 2.5 mm or less on an anteroposterior radiograph, or Kellgren and Lawrence grade 2 or higher. Possible causes of secondary osteoporosis were identified by review of medical records. Results The age-adjusted odds ratio (OR for subjects with hip fracture having radiographic hip OA was 0.30 (95% confidence interval [95% CI] 0.12-0.74 for men and 0.33 (95% CI 0.19-0.58 for women, compared to controls. The probability for subjects with hip fracture and hip OA having a secondary cause of osteoporosis was three times higher than for subjects with hip fracture without hip OA. Conclusion The results of our study support an inverse relationship between hip fractures and hip OA.

  5. Unilateral hip osteoarthritis: can we predict the outcome of the other hip?

    Energy Technology Data Exchange (ETDEWEB)

    Vossinakis, I.C. [General Hospital of Volos, Orthopaedic Department, Volos (Greece); Georgiades, G. [General Hospital of Tripoli, Tripoli Greece, Orthopaedic Department, Athens (Greece); Hartofilakidis, G. [University of Athens Medical School, Department of Orthopaedics, Athens (Greece); Kafidas, D.

    2008-10-15

    The objective of this study was to define, in unilateral hip osteoarthritis (OA), factors predicting the outcome of the other hip. We examined the anteroposterior radiographs of the pelvis of 95 white patients with unilateral idiopathic (56 patients) or secondary to congenital hip diseases (39 patients) OA. The other hip was free from symptoms (pain or limping) at the initial examination and without radiographic evidence of OA; it was what we call a ''normal'' hip. Two parameters were evaluated: (1) the type of osteoarthritis of the involved hip and (2) the range of four radiographic indices of the contralateral hip: the sourcil inclination (weight-bearing surface), the acetabular angle, the Wiberg's center-edge angle, and the neck-shaft angle. Follow-up radiographs for the hips that remained OA-free were available for 10 to 35 years and for those that developed OA, at the time of initial symptoms, range 2 to 31 years. Logistic regression analysis showed that the presence of idiopathic OA in one hip had a statistically significant effect on the development of OA on the other hip (p<0.001). Minor deviations of radiographic indices of the contralateral hip is not a predictive factor for its outcome. When the radiographic indices are examined together with the pathology of the involved hip, only WBS was shown to have a significant effect to the development of OA and its type (p < 0.001). The following conclusions can be drawn from this study: 1. Patient with idiopathic OA of one hip is at increased risk of developing OA in the other hip. 2. The outcome of the other hip cannot be predicted only on the basis of the evaluation of its radiographic indices. 3. Among the different indices, WBS seems to have a strong influence toward the development of OA. (orig.)

  6. Reconstruction of the Acetabulum in Developmental Dysplasia of the Hip in total hip replacement

    OpenAIRE

    Vasileios Sakellariou; Michael Christodoulou; Gregory Sasalos; George Babis

    2014-01-01

    Developmental dysplasia of the hip (DDH) or congenital hip dysplasia (CDH) is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DDH, 32.5 years for low dislocation, 31.2 years for high dislocation with a false acetabulum, and 46.4...

  7. The hip-spine connection: understanding its importance in the treatment of hip pathology.

    Science.gov (United States)

    Redmond, John M; Gupta, Asheesh; Nasser, Rima; Domb, Benjamin G

    2015-01-01

    EDUCATIONAL OBJECTIVES As a result of reading this article, physicians should be able to: 1. Discuss the kinematic relationship between the hip and lumbar spine. 2. Explain the innervation of the hip and lumbar spine and how they relate to one another. 3. Recognize the effect of hip disease on the lumbar spine in an athletic population, prior to the onset of degenerative changes. 4. Describe an algorithm for diagnosis and treatment of patients who present with concomitant hip and lumbar spine pain. The hip and lumbar spine are closely related and can create similar patterns of pain and dysfunction. Diagnosis and treatment of hip and spine-related conditions can be challenging due to symptom overlap. Successful evaluation and treatment of hip and lumbar spine conditions requires a thorough understanding the hip-spine connection. Historically the hip-spine connection has been considered in the context of arthrosis; however, the hip-spine connection also needs to be considered in a younger athletic population. The purpose of this review is to describe the hip-spine connection, discuss the clinical implications of this connection, and offer an approach to diagnosis and treatment. PMID:25611411

  8. Improving hip surgery patients’ outcomes:

    DEFF Research Database (Denmark)

    Bagger, Bettan; Poulsen, Dorthe Varning; Taylor Kelly, Hélène;

    2013-01-01

    competencies -the development of an e-health concept based upon new knowledge concerning rehabilitation aimed at patients, their families and health professionals -the development of new clinical practice guidelines The project integrates innovative public health services via e-based solutions.......This presentation focuses upon the improvement of hip surgery patients’ outcomes with respect to health promotion and rehabilitation. The overall aims of the EU financed orthopedic nursing project will be introduced. Speakers highlight the project’s contribution to: -the development of nurse...

  9. Radiology of total hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, H.J.; Lovelock, J.E.; McCollister Evarts, C.; Geyer, D.

    1984-06-01

    The radiology of total hip replacement (THR) and its complications is reviewed in conjunction with a long-term follow-up study on 402 patients with 501 prostheses. The indications, contraindications, biomechanics, and operative management of these patients is discussed. Clinical complications such as deep vein thrombosis, pulmonary embolism, and hemorrhage are mentioned. Postoperative infections including granulomatous pseudotumors, dislocations and fractures, true loosening of the prosthesis, and heterotopic bone formation (HBF) are discussed and illustrated. The importance of differentiating the lucent line from true loosening is stressed. Mechanical and other clinical complications which are largely ignored by radiologists are also discussed. The uses of arthrography and bone scanning are included.

  10. Biomechanics of the Hip Capsule and Capsule Management Strategies in Hip Arthroscopy.

    Science.gov (United States)

    Nepple, Jeffrey J; Smith, Matthew V

    2015-12-01

    Recent advances in our understanding of the function of the hip capsule have clarified its importance to normal hip function and kinematics. The iliofemoral ligament is the primary stabilizing structure for controlling anterior translation and external rotation of the hip, and is violated by the arthroscopic interportal capsulotomy. Microinstability of the hip occurring after surgical trauma remains a poorly defined clinical entity. In certain at-risk populations, capsular repair should be considered as part of an arthroscopic hip procedure to achieve optimal outcomes and avoid iatrogenic instability (dislocation or microinstability). Despite a lack of conclusive evidence-based indications, we recommend capsular repair in the settings of borderline hip dysplasia (or dysplastic variants such as increased femoral anteversion), hip hypermobility, connective tissue disorders, and traumatic or atraumatic instability. With careful attention to arthroscopic capsular management, adequate exposure can be achieved and reproducibly allow for an effective capsular repair when indicated. PMID:26524549

  11. Dilemmas in Uncemented Total Hip Arthroplasty

    NARCIS (Netherlands)

    Goosen, J.H.M.

    2009-01-01

    In this thesis, different aspects that are related to the survivorship and clinical outcome in uncemented total hip arthroplasty are analysed. In Chapter 2, the survival rate, Harris Hip score and radiographic features of a proximally hydroxyapatite coated titanium alloy femoral stem (Bi-Metric, Bio

  12. Revision Total Hip Replacement: A Case Report

    Directory of Open Access Journals (Sweden)

    Md Hafizur Rahman

    2013-07-01

    Full Text Available Total hip replacement is a reconstructive procedure that has improved the management of those diseases of the hip joint that have responded poorly to conventional medical therapy. Conventional, primary total hip replacement is a durable operation in the majority of patients. A hip replacement is a mechanical device with parts that are assembled before and during the operation. But the possible complications of total hip arthroplasty, and its clinical performance over time, is a challenging occasion to the surgeons, and such a challenge we faced with our presenting patient. A 68 year old lady with history of cemented bipolar hemiarthroplasty done in a tertiary care hospital, due to fracture neck of the left femur having the history of diabetes, chronic kidney disease, heart disease, anaemia, and mental disorders presented with loosened prosthesis, thinning of medial proximal cortex of the femur which had broken within few months after surgery. She complained of painful walking at left hip joint. There was also evidence of chronic infective and degenerative arthritis of acetabular component of the affected hip joint. Cemented revision total hip replacement surgery was performed with expert multidisciplinary involvement. On 2nd postoperative day the patient was allowed to walk on operated limb with the aid of walker. On 12th postoperative day all the stitches were removed and wound was found healthy.

  13. A new algorithm for hip fracture surgery

    DEFF Research Database (Denmark)

    Palm, Henrik; Krasheninnikoff, Michael; Holck, Kim; Lemser, Tom; Foss, Nicolai Bang; Jacobsen, Steffen; Kehlet, Henrik; Gebuhr, Peter

    2012-01-01

    Background and purpose Treatment of hip fracture patients is controversial. We implemented a new operative and supervision algorithm (the Hvidovre algorithm) for surgical treatment of all hip fractures, primarily based on own previously published results. Methods 2,000 consecutive patients over 5...

  14. Acute cognitive dysfunction after hip fracture

    DEFF Research Database (Denmark)

    Bitsch, M S; Foss, N B; Kristensen, B B;

    2006-01-01

    Patients undergoing hip fracture surgery often experience acute post-operative cognitive dysfunction (APOCD). The pathogenesis of APOCD is probably multifactorial, and no single intervention has been successful in its prevention. No studies have investigated the incidence of APOCD after hip...... fracture surgery in an optimized, multimodal, peri-operative rehabilitation regimen....

  15. Hip Arthroscopy: Tales From the Crypt.

    Science.gov (United States)

    Matsuda, Dean K; Philippon, Marc J; Safran, Marc R; Sampson, Thomas G

    2016-01-01

    Complications after hip arthroscopy vary in frequency and severity, even for experienced surgeons. It is important for surgeons to be aware of some of the more dramatic, often unusual, and always memorable (nightmarish) complications of hip arthroscopy and understand how they are caused, how they can be treated, and how they can be prevented. PMID:27049210

  16. TREATMENT OF NEUROLOGICAL CONGENITAL HIP LUXATION

    Directory of Open Access Journals (Sweden)

    Iulian ICLEANU

    2015-11-01

    Full Text Available Congenital hip luxation is a disorder which evolves in time. Teratological hip dislocation is a distinct form of hip luxation, which usually appears with other disorders. These hips are dislocated before birth. In this thesis we will try to elaborate a recovery program, through physical exercises, which will help us realize our treatment objectives: diminishing articular stiffness, increasing articular mobility, increasing muscle strength, recalibration of agonist and antagonist balances and reeducating gait. The specific objectives of the study consist of the particularization of the recovery programs based on age, illness stage (dysplasia or luxation and either surgical or non-surgical intervention. To show the importance of physiotherapy in gait rehabilitation of a child with hip dislocation we started from the hypothesis: using an adequate rehabilitation program after an individualized methodology, optimizes the functional recovery and ensures the gains of hip stability and the formation of an engram of gait as close as it could be to the normal one. We present a case of neurological congenital hip dislocation where the treatment initiated early is showing good results. Results obtained are significantly different and we came to the conclusion that starting an untimely analytical kinetic treatment and globally personalizing it to every patient has better biomechanical results for the hip.

  17. Hip-hop and urban studies

    NARCIS (Netherlands)

    R. Jaffe

    2014-01-01

    How can urban studies research engage fruitfully with hip-hop? This contribution responds to the essays by David Beer and Martin Lamotte on ‘street music’, urban ethnography and ghettoized communities. It discusses how a social science engagement with hip-hop texts might differ from cultural studies

  18. Simultaneous and staged bilateral total hip arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Joergensen, Christoffer Calov; Husted, Henrik;

    2013-01-01

    Bilateral total hip arthroplasty (BTHA) and bilateral simultaneous total hip arthroplasty (BSTHA) are done increasingly. Previous studies evaluating outcomes after bilateral procedures have found different results. The aim of this study was to investigate length of hospital stay (LOS), 30 days...

  19. Pertunjukan Teater Karo Hip Hop Kontemporer KAI

    Directory of Open Access Journals (Sweden)

    Silvia Anggreni Purba

    2013-11-01

    Full Text Available Pertunjukan ini berawal dari sebuah ide untuk mengkolaborasikan tradisi Karo dengan budaya populer. Dengan cara seperti ini pertunjukan bisa dinikmati tanpa batasan bahasa dan budaya. Proses menggabungkan dua budaya yang berbeda merupakan bentuk budaya hibrida dan terjadi akibat proses globalisasi. Melalui proses pengendapan pengamatan dan kesan yang kuat, pertunjukan ini dibawa ke dalam bentuk Hip Hop. Pertunjukan ini merupakan bagian dari sebuah tragedi modern dengan karakter destruktif, mengeksplorasi emosi dan menyampaikannya kepada penonton. Eksplorasi budaya Karo dan tari Hip Hop sebagai bahasa simbol mampu memperkuat kata-kata. Gerak tidak diungkapkan dengan kata lisan tetapi disajikan melalui gerak tari Hip Hop. Penafsiran legenda dan teks ke dalam gerak, melalui proses pelatihan di laboratorium sebagai proses pencarian dan eksperimentasi diwujudkan dengan mempertimbangkan unsur-unsur dasar dari Hip Hop, unsur budaya Karo dan tontonan. Karo Hip Hop diharapkan menjadi bentuk estetika teater modern yang diinginkan tanpa kehilangan tradisi.Kata kunci: Tari Karo kontemporer, Hip-hop, budaya hibridaABSTRACTPertunjukan Teater Karo Hip Hop Kontemporer KAI. The performance of Karo Theater collaborated with Hip Hop stems from a simple idea to collaborate Karo cultural traditions with popular culture. The performances can be enjoyed without having limitation on the language and culture. The process of combining two different cultures is a form of hybrid culture, and it may occur due to the globalization process. Through the process of deposition of the observations and strong impression, this performance is then brought into the form of Hip Hop as a preferred form which is energetic, personal and global. This performance is part of a modern tragedy with its destructive character which has explored the emotion and has presented it to the audiences. The exploration of Karo cultural tradition and Hip Hop dance as a language of symbols is able to

  20. Radiological Assessment of the Sacrofemoral Angle: A Novel Method to Measure the Range of Hip Joint Flexion

    Institute of Scientific and Technical Information of China (English)

    Xian-Zhao Wei; Xi-Ming Xu; Fei Wang; Ming Li; Zi-Min Wang

    2015-01-01

    Background:A quantitative and accurate measurement of the range of hip joint flexion (RHF) is necessarily required in the evaluation of disordered or artificial hip joint function.This study aimed to assess a novel method to measure RHF more accurately and objectively.Methods:Lateral radiographs were taken of 31 supine men with hip joints extended or flexed.Relevant angles were measured directly from the radiographs.The change in the sacrofemoral angle (SFA) (the angle formed between the axis of the femur and the line tangent to the upper endplate of S1) from hip joint extension to hip joint flexion,was proposed as the RHF.The validity of this method was assessed via concomitant measurements of changes in the femur-horizontal angle (between the axis of the femur and the horizontal line) and the sacrum-horizontal angle (SHA) (between the line tangent to the upper endplate of S l and the horizontal line),the difference of which should equal the change in the SFA.Results:The mean change in the SFA was 112.5 ± 7.4°,and was independent of participant age,height,weight,or body mass index.The mean changes in the femur-horizontal and SHAs were 123.0 ± 6.4° and 11.4 ±-3.0°,respectively.This confirmed that the change of SFA between hip joint extension and hip joint flexion was equal to the difference between the changes in the femur-horizontal and SHAs.Conclusions:Using the SFA,to evaluate RHF could prevent compromised measurements due to the movements of pelvis and lumbar spine during hip flexion,and is,therefore,a more accurate and objective method with reasonable reliability and validity.

  1. Minimally invasive medial hip approach.

    Science.gov (United States)

    Chiron, P; Murgier, J; Cavaignac, E; Pailhé, R; Reina, N

    2014-10-01

    The medial approach to the hip via the adductors, as described by Ludloff or Ferguson, provides restricted visualization and incurs a risk of neurovascular lesion. We describe a minimally invasive medial hip approach providing broader exposure of extra- and intra-articular elements in a space free of neurovascular structures. With the lower limb in a "frog-leg" position, the skin incision follows the adductor longus for 6cm and then the aponeurosis is incised. A slide plane between all the adductors and the aponeurosis is easily released by blunt dissection, with no interposed neurovascular elements. This gives access to the lesser trochanter, psoas tendon and inferior sides of the femoral neck and head, anterior wall of the acetabulum and labrum. We report a series of 56 cases, with no major complications: this approach allows treatment of iliopsoas muscle lesions and resection or filling of benign tumors of the cervical region and enables intra-articular surgery (arthrolysis, resection of osteophytes or foreign bodies, labral suture). PMID:25164350

  2. Quo Vadis, Artificial Intelligence?

    OpenAIRE

    Alfons Schuster; Daniel Berrar; Naoyuki Sato

    2010-01-01

    Since its conception in the mid 1950s, artificial intelligence with its great ambition to understand and emulate intelligence in natural and artificial environments alike is now a truly multidisciplinary field that reaches out and is inspired by a great diversity of other fields. Rapid advances in research and technology in various fields have created environments into which artificial intelligence could embed itself naturally and comfortably. Neuroscience with its desire to understand nervou...

  3. Anticipatory Artificial Autopoiesis

    OpenAIRE

    DuBois, Daniel; Holmberg, Stig C.

    2010-01-01

    In examining relationships between autopoiesis and anticipation in artificial life (Alife) systems it is demonstrated that anticipation may increase efficiency and viability in artificial autopoietic living systems. This paper, firstly, gives a review of the Varela et al [1974] automata algorithm of an autopoietic living cell. Some problems in this algorithm must be corrected. Secondly, a new and original anticipatory artificial autopoiesis algorithm for automata is presented. ...

  4. Artificial cognition architectures

    CERN Document Server

    Crowder, James A; Friess, Shelli A

    2013-01-01

    The goal of this book is to establish the foundation, principles, theory, and concepts that are the backbone of real, autonomous Artificial Intelligence. Presented here are some basic human intelligence concepts framed for Artificial Intelligence systems. These include concepts like Metacognition and Metamemory, along with architectural constructs for Artificial Intelligence versions of human brain functions like the prefrontal cortex. Also presented are possible hardware and software architectures that lend themselves to learning, reasoning, and self-evolution

  5. Doped Colloidal Artificial Ice

    OpenAIRE

    Libal, A.; Reichhardt, C. J. Olson; Reichhardt, C.

    2015-01-01

    We examine square and kagome artificial spin ice for colloids confined in arrays of double-well traps. Unlike magnetic artificial spin ices, colloidal and vortex artificial spin ice realizations allow creation of doping sites through double occupation of individual traps. We find that doping square and kagome ice geometries produces opposite effects. For square ice, doping creates local excitations in the ground state configuration that produce a local melting effect as the temperature is rai...

  6. Inteligencia artificial en vehiculo

    OpenAIRE

    Amador Díaz, Pedro

    2012-01-01

    Desarrollo de un robot seguidor de líneas, en el que se implementan diversas soluciones de las áreas de sistemas embebidos e inteligencia artificial. Desenvolupament d'un robot seguidor de línies, en el qual s'implementen diverses solucions de les àrees de sistemes encastats i intel·ligència artificial. Follower robot development of lines, in which various solutions are implemented in the areas of artificial intelligence embedded systems.

  7. Analysis of hip perfusion at early and reversible stages of aseptic hip necrosis

    International Nuclear Information System (INIS)

    Aim: A proper early diagnosis of aseptic hip necrosis is very important for further therapy.Since there has always been a question of the amount of perfusion in hips at different stages of aseptic hip necrosis we tried to impartially examine the perfusion in hips at early and reversible stages of aseptic hip necrosis. Material and Methods:Study included 143 patients with aseptic hip necrosis.The 550-740 MBq of Tc-99m-DPD were on bolus injected.All patients were subjected to 3-phase scintigraphy of hips and quantitative calculation of relative perfusion in the artery phase (3T) at early and repeated at reversible stages of aseptic hip necrosis. Results: At the early stage of aseptic hip necrosis the obtained 3T was decreased from 0.94-0.69 (3T=0.80).Scintigrams showed a moderate increase or diffuse accumulation. At the reversible stages we obtained 3T decreased from 0.92-0.71 (3T=0.79) thus evidencing hypoperfusion.Scintigrams showed an diffuse increased accumulation. Conclusion: With the aseptic hip necrosis quantitative analysis of perfusion in the artery phase-3T indicates that the perfusion is decreased at all stages of the process which however shows a significantly falling trend with the progress of the disease

  8. Reconstruction of the Acetabulum in Developmental Dysplasia of the Hip in Total Hip Replacement

    Directory of Open Access Journals (Sweden)

    Vasileios Sakellariou

    2014-09-01

    Full Text Available Developmental dysplasia of the hip (DDH or congenital hip dysplasia (CDH is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DDH, 32.5 years for low dislocation, 31.2 years for high dislocation with a false acetabulum, and 46.4 years for high dislocation without a false acetabulum. Thorough understanding of the bony and soft tissue deformities induced by dysplasia is crucial for the success of total hip arthroplasty. It is important to evaluate the existing acetabular deformity three-dimensionally, and customize the correction in accordance with the quantity and location of ace tabular deficiencies. Acetabular reconstruction in patients with DDH is hallenging. Interpretation of published data is difficult and should be done with caution because most series include patients with different types of hip disease. In general, the complication rate associated with THA is higher in patients with hip dysplasia than it is in patients with osteoarthritis. Overall, clinical and functional outcomes following THA in patients hip dysplasia (DDH differ from those treated for primary hip osteoarthritis, possibly due to the lower age and level of activity. Although function scores decline with age, the scores for pain and range of motion presented with a statistically significant improvement in the long-term.

  9. Estimation of appropriate lubricating film thickness in ceramic-on-ceramic hip prostheses

    Science.gov (United States)

    Tauviqirrahman, M.; Muchammad, Bayuseno, A. P.; Ismail, R.; Saputra, E.; Jamari, J.

    2016-04-01

    Artificial hip prostheses, consisting of femoral head and acetabular cup are widely used and have affected the lives of many people.However, the primary issue associated with the long term performance of hip prostheses is loosening induced by excessive wear during daily activity. Therefore, an effective lubrication is necessary to significantly decrease the wear. To help understand the lubricating performance of such typical hip joint prostheses, in the present paper a hydrodynamic lubrication model based on Reynolds equationwas introduced. The material pairs of ceramic acetabular cup against ceramic femoral head was investegated.The main aim of this study is to investigate of the effect of loading on the formation of lubricating film thickness.The model of a ball-in-socket configuration was considered assuming that the cup was stationary while the ball was to rotate at a steady angular velocityvarying loads.Based on simulation result, it was found that to promote fluid film lubrication and prevent the contacting components leading to wear, the film thickness of lubricant should be determined carefully based on the load applied. This finding may have useful implication in predicting the failure of lubricating synovial fluid film and wear generation in hip prostheses.

  10. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... resurfacing is similar but also different from hip -- standard hip replacement. If you saw the standard hip replacement video, we removed by using a ... techniques are similar -- actually, slightly larger than the standard small-incision hip. So in many respects it’s ...

  11. Mechanical Evaluation of Polymer Composite Hip Protectors

    Directory of Open Access Journals (Sweden)

    Jose Daniel Diniz Melo

    2010-01-01

    Full Text Available Hip fractures often result in serious health implications, particularly in the geriatric population, and have been related to long-term morbidity and death. In most cases, these fractures are caused by impact loads in the area of the greater trochanter, which are produced in a fall. This work is aimed at developing hip protectors using composite materials and evaluating their effectiveness in preventing hip fractures under high impact energy (120 J. The hip protectors were developed with an inner layer of energy absorbing soft material and an outer rigid shell of fiberglass-reinforced polymer composite. According to the experimental results, all tested configurations proved to be effective at reducing the impact load to below the average fracture threshold of proximal femur. Furthermore, an addition of Ethylene Vinyl Acetate (EVA to the impacted area of the composite shell proved to be beneficial to increase impact strength of the hip protectors. Thus, composite hip protectors proved to be a viable alternative for a mechanically efficient and cost-effective solution to prevent hip fractures.

  12. Artificial life and life artificialization in Tron

    Directory of Open Access Journals (Sweden)

    Carolina Dantas Figueiredo

    2012-12-01

    Full Text Available Cinema constantly shows the struggle between the men and artificial intelligences. Fiction, and more specifically fiction films, lends itself to explore possibilities asking “what if?”. “What if”, in this case, is related to the eventual rebellion of artificial intelligences, theme explored in the movies Tron (1982 and Tron Legacy (2010 trat portray the conflict between programs and users. The present paper examines these films, observing particularly the possibility programs empowering. Finally, is briefly mentioned the concept of cyborg as a possibility of response to human concerns.

  13. Traumatic inferior hip dislocation: a rare adult case with ipsilateral bifocal hip fracture

    Science.gov (United States)

    El Hajj Moussa, Majd; Tawk, Charbel; Hoyek, Fadi; Lahoud, Jean-Claude

    2016-01-01

    Inferior dislocation is a rare type of hip dislocation, especially in adults. Few cases have been reported; most of them were isolated. This is the case of a traumatic adult hip dislocation after a road traffic accident. Reduction was made under general anaesthesia; a CT-Scan after the reduction showed a bifocal non-displaced hip fracture. In this article, we present a small review of the literature and we discuss the possible mechanism of hip dislocation. We found through our case study that this condition is not exclusive to children and CT-Scan is mandatory after the reduction of hip dislocation to eliminate any associated injury. To our knowledge, a bifocal hip fracture has not previously been documented, in the English language literature. PMID:27141043

  14. Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

    LENUS (Irish Health Repository)

    Brennan, S A

    2009-04-01

    PURPOSE: To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS: 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent uncemented THA using the trident acetabular cup. Obese elderly women at risk of femoral neck fracture and patients with large subchondral pseudocysts or a history of avascular necrosis of the femoral head were assigned to uncemented THA. Acetabular reamings were collected; marginal osteophytes were not included. The reamings were dehydrated, defatted, and weighed. RESULTS: The mean weight of acetabular reamings was not significantly different between patients undergoing hip resurfacing and uncemented THA (p=0.57). CONCLUSION: In hip resurfacing, the use of an appropriately small femoral component avoids oversizing the acetabular component and removal of excessive bone stock.

  15. Pain in the hip joint

    Directory of Open Access Journals (Sweden)

    Yuri Aleksandrovich Olyunin

    2013-01-01

    Full Text Available Pathological changes that develop in the hip joints (HJ have different origins and mechanisms of development, but their main manifestation is pain. The nature of this pain cannot be well established on frequent occasions. The English-language medical literature currently classifies such disorders as greater trochanter pain syndrome (GTPS. Its major signs are chronic pain and local palpatory tenderness in the outer part of HJ. The development of GTPS may be associated with inflammation of the synovial bursae situated in the greater tronchanter, as well as with tendinitis, myorrhexis, iliotibial band syndrome, and other local changes in the adjacent tissues or with systemic diseases. So GTPS may be characterized as regional pain syndrome that frequently mimics pain induced by different diseases, including myofascial pain syndrome, osteoarthrosis, spinal diseases, etc.

  16. Complications after total hip replacement

    International Nuclear Information System (INIS)

    Complications seen after long-term follow-up examinations of total hip replacement should be treated immediately and completely. In the past decade a considerable increase in revisions has been noted. Radiographic assessment may be regarded as an effective means in diagnosing prosthetic complications from the surgeon's point of view. Examples are given. The difficulties in radiographic assessment of complications after cementless implanation or cemented prostheses without contrast media are mentioned. Prosthesis-related complications, such as mechanical loosening, infection with and without loosening, fatigue fractures and wear, fractures of the femur or pelvis, dislocations and surgical failures, are illustrated, as are clinical courses with gross loss of bone stock after repeated surgery and delayed revisions. Complications not related to the prosthesis such as periarticular ossification, muscle deficiencies, and nervous and vascular lesions are also explained using examples. (orig.)

  17. Pain in the hip joint

    Directory of Open Access Journals (Sweden)

    Yuri Aleksandrovich Olyunin

    2013-06-01

    Full Text Available Pathological changes that develop in the hip joints (HJ have different origins and mechanisms of development, but their main manifestation is pain. The nature of this pain cannot be well established on frequent occasions. The English-language medical literature currently classifies such disorders as greater trochanter pain syndrome (GTPS. Its major signs are chronic pain and local palpatory tenderness in the outer part of HJ. The development of GTPS may be associated with inflammation of the synovial bursae situated in the greater tronchanter, as well as with tendinitis, myorrhexis, iliotibial band syndrome, and other local changes in the adjacent tissues or with systemic diseases. So GTPS may be characterized as regional pain syndrome that frequently mimics pain induced by different diseases, including myofascial pain syndrome, osteoarthrosis, spinal diseases, etc.

  18. The hip abductors at MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, A., E-mail: adrienne.hoffmann@balgrist.ch [Department of Radiology, University Hospital Balgrist, Forchstrasse 340, CH-8008 Zürich (Switzerland); Pfirrmann, C.W.A., E-mail: christian.pfirrmann@balgrist.ch [Department of Radiology, University Hospital Balgrist, Forchstrasse 340, CH-8008 Zürich (Switzerland)

    2012-12-15

    Imaging of the hip abductors plays an increasing role for the evaluation of greater trochanteric pain in patients with and without total hip arthroplasty. This review article addresses the anatomy of the hip abductors and their intervening bursae. It highlights different possible imaging appearances such as tendinopathy or partial and full thickness tears of the gluteal tendons. Muscle atrophy or fatty degeneration of the gluteal muscles is an important reason for limping. Inflammatory diseases such as hydroxyapatite crystal deposition disease or spondylarthritis have to be considered. Knowledge of these different entities is important to achieve optimal treatment and outcomes.

  19. Artificial insemination in poultry

    Science.gov (United States)

    Artificial insemination is a relative simple yet powerful tool geneticists can employ for the propagation of economically important traits in livestock and poultry. In this chapter, we address the fundamental methods of the artificial insemination of poultry, including semen collection, semen evalu...

  20. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented or uncemented prosthesis. 888.3390 Section 888.3390 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a...

  1. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... metal/polyacetal cemented prosthesis. 888.3380 Section 888.3380 Food and Drugs FOOD AND DRUG... Devices § 888.3380 Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis is a...

  2. Hybrid SPECT/CT for the assessment of a painful hip after uncemented total hip arthroplasty

    OpenAIRE

    Dobrindt, Oliver; Amthauer, Holger; Krueger, Alexander; Ruf, Juri; Wissel, Heiko; Grosser, Oliver S.; Seidensticker, Max; Lohmann, Christoph H

    2015-01-01

    Background The diagnosis of hip pain after total hip replacement (THR) represents a highly challenging question that is of increasing concern to orthopedic surgeons. This retrospective study assesses bone scintigraphy with Hybrid SPECT/CT for the diagnosis of painful THR in a selected cohort of patients. Methods Bone SPECT/CT datasets of 23 patients (mean age 68.9 years) with a painful hip after THR were evaluated. Selection of the patients required an inconclusive radiograph, normal serum le...

  3. Metal on metal hip resurfacing versus uncemented custom total hip replacement - early results

    Directory of Open Access Journals (Sweden)

    Muirhead-Allwood Sarah K

    2010-02-01

    Full Text Available Abstract Introduction There is no current consensus on the most appropriate prosthesis for treating symptomatic osteoarthritis (OA of the hip in young, active patients. Modern metal on metal hip resurfacing arthroplasty (HR has gained popularity as it is theoretically more stable, bone conserving and easier to revise than total hip arthroplasty. Early results of metal on metal resurfacing have been encouraging. We have compared two well matched cohorts of patients with regard to function, pain relief and patient satisfaction. Methods This prospective study compares 2 cohorts of young, active patients treated with hip resurfacing (137 patients, 141 hips and custom uncemented (CADCAM stems (134 patients, 141 hips. All procedures were performed by a single surgeon. Outcome measures included Oxford, WOMAC and Harris hip scores as well as an activity score. Statistical analysis was performed using the unpaired student's t-test. Results One hundred and thirty four and 137 patients were included in the hip replacement and resurfacing groups respectively. The mean age of these patients was 54.6 years. The mean duration of follow up for the hip resurfacing group was 19.2 months compared to 13.4 months for the total hip replacement group. Pre operative oxford, Harris and WOMAC scores in the THA group were 41.1, 46.4 and 50.9 respectively while the post operative scores were 14.8, 95.8 and 5.0. In the HR group, pre- operative scores were 37.0, 54.1 and 45.9 respectively compared to 15.0, 96.8 and 6.1 post operatively. The degree of improvement was similar in both groups. Conclusion There was no significant clinical difference between the patients treated with hip resurfacing and total hip arthroplasty in the short term.

  4. UNCEMENTED PRIMARY TOTAL HIP ARTHROPLASTY FOR OSTEONECROSIS OF HIP WITH SECONDARY OSTEOARTHRITIS IN YOUNG ADULTS

    Directory of Open Access Journals (Sweden)

    Chatla

    2016-03-01

    Full Text Available BACKGROUND Osteonecrosis of the femoral head is a progressive disease that generally affects patients in the third through fifth decade of life, if left untreated. Currently, 18% of all Total Hip Arthroplasty performed in USA are done for Osteonecrosis.(1 The aetiology for the Osteonecrosis varies from idiopathic, alcohol intoxication, steroid abuse or due to childhood hip disorders and hip trauma. We have selected 40 patients suffering from advanced femoral head osteonecrosis with subchondral collapse leading to Osteoarthritis of hip in young adults, treated by uncemented primary total hip replacement. This study is aimed to suggest that uncemented total hip arthroplasty can be applied predictably to this younger, potentially more active patient population. MATERIAL AND METHODS We have done 54 uncemented primary hips in 40 cases with mean follow-up of 5.5 years. The average age of the patient at the time of surgery was 43 years. All the hips are clinically and radiologically examined both pre- and post-operatively. All the cases are operated through postero-lateral approach and have used the fully Hydroxyapatite coated femoral straight stem designed for press fit insertion and hemispherical HA-coated cup inserted with press fit and in few cases we used an HA-coated screw. The patients are under regular follow-up. RESULTS All the patients are reviewed at 6 weeks, 3 months, 6 months and yearly thereafter. The clinical and functional status was recorded using the Harris Hip Score and WOMAC Hip Score. The mean Harris score has improved from an average of 44 points to an average of 93 points postoperatively; 94% showed good-to-excellent results, 2% of cases had shortening, one case developed hip dislocation after two weeks due to unguarded physiotherapy. CONCLUSION The short-term results of cementless total hip arthroplasty in patients with Osteonecrosis of the femoral head were encouraging. We await further follow-up to see if these promising

  5. Hip dislocations after 2,734 elective unilateral fast-track total hip arthroplasties

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer C; Kjaersgaard-Andersen, Per; Solgaard, Søren; Kehlet, Henrik; Hansen, Torben Bæk

    2014-01-01

    STUDY DESIGN: Retrospective review of prospectively collected data. OBJECTIVE: To investigate the incidence of hip dislocation 90 days after total hip arthroplasty in relation to time after surgery, mechanism of dislocation and predisposing factors. METHODS: Prospective data on preoperative patient......-track total hip arthroplasty. Further studies including detailed information on patient and prosthesis characteristics, and activity restrictions are needed to reduce the risk of dislocation....

  6. Changes in walking and running in patients with hip dysplasia

    OpenAIRE

    Jacobsen, Julie S; Nielsen, Dennis B; Sørensen, Henrik; Søballe, Kjeld; Mechlenburg, Inger

    2013-01-01

    Background and purpose Earlier studies have suggested that the hip extension angle and the hip flexor moment in walking are affected by hip dysplasia, but to our knowledge there have been no reports on running or evaluations of self-reported health. We evaluated differences in walking, running, and self-reported health between young adults with symptomatic hip dysplasia and healthy controls. Patients and methods Walking and running in 32 patients with hip dysplasia, mean 34 (18–53) years old,...

  7. Hip and ankle range of motion and hip muscle strength in young female ballet dancersand controls

    OpenAIRE

    Bennell, K; Khan, K. M.; Matthews, B.; De Gruyter, M.; Cook, E; Holzer, K; Wark, J D

    1999-01-01

    OBJECTIVES: To compare the hip and ankle range of motion and hip muscle strength in 8-11 year old novice female ballet dancers and controls. METHODS: Subjects were 77 dancers and 49 controls (mean (SD) age 9.6 (0.8) and 9.6 (0.7) years respectively). Supine right active hip external rotation (ER) and internal rotation (IR) were measured using an inclinometer. A turnout protractor was used to assess standing active turnout range. The measure of ER achieved from below the hip during turno...

  8. Low revision rate after total hip arthroplasty in patients with pediatric hip diseases

    DEFF Research Database (Denmark)

    Engesæter, Lars B; Engesæter, Ingvild Ø; Fenstad, Anne Marie;

    2012-01-01

    Background The results of primary total hip arthroplasties (THAs) after pediatric hip diseases such as developmental dysplasia of the hip (DDH), slipped capital femoral epiphysis (SCFE), or Perthes' disease have been reported to be inferior to the results after primary osteoarthritis of the hip (OA.......9%) were operated due to pediatric hip diseases (3.1% for Denmark, 8.8% for Norway, and 1.9% for Sweden) and 288,435 THAs (77.8%) were operated due to OA. Unadjusted 10-year Kaplan-Meier survival of THAs after pediatric hip diseases (94.7% survival) was inferior to that after OA (96.6% survival......). Consequently, an increased risk of revision for hips with a previous pediatric hip disease was seen (risk ratio (RR) 1.4, 95% CI: 1.3-1.5). However, after adjustment for differences in sex and age of the patients, and in fixation of the prostheses, no difference in survival was found (93.6% after pediatric hip...

  9. Hip-hop, Onegin - pop! / Tatjana Aleksandrova

    Index Scriptorium Estoniae

    Aleksandrova, Tatjana, 1945-

    2004-01-01

    Erateatrikooli KS, mida juhib Svetlana Krassman, lavastus A. Pushkini poeemi "Jevgeni Onegin" motiividel. Noortelavastuse muusikalises seades kasutatakse klassikalise muusika aranzheeringuid ja räppi, kostüümidraamat koos hip-hop rõivastiiliga

  10. Total Hip Replacement (Arthroplasty) (Beyond the Basics)

    Science.gov (United States)

    ... stiffening caused by extra bone formation, also called heterotopic ossification, is a process in which some soft ... replacement (prosthetic) parts, with the goal of relieving pain and improving function. ● Most patients require total hip ...

  11. Microbial assisted High Impact Polystyrene (HIPS) degradation.

    Science.gov (United States)

    Mohan, Arya J; Sekhar, Vini C; Bhaskar, Thallada; Nampoothiri, K Madhavan

    2016-08-01

    The efficacy of newly isolated Pseudomonas and Bacillus strains to degrade brominated High Impact Polystyrene (HIPS) was investigated. Viability of these cultures while using e-plastic as sole carbon source was validated through Triphenyl Tetrazolium Chloride (TTC). Four days incubation of HIPS emulsion with Bacillus spp. showed 94% reduction in turbidity and was 97% with Pseudomonas spp. Confirmation of degradation was concluded by HPLC, NMR, FTIR, TGA and weight loss analysis. NMR spectra of the degraded film revealed the formation of aliphatic carbon chain with bromine and its release. FTIR analysis of the samples showed a reduction in CH, CO and CN groups. Surface changes in the brominated HIPS film was visualized through SEM analysis. Degradation with Bacillus spp showed a weight loss of 23% (w/w) of HIPS film in 30days. PMID:26993201

  12. Epidemiology of hip fracture: Worldwide geographic variation

    Directory of Open Access Journals (Sweden)

    Dinesh K Dhanwal

    2011-01-01

    Full Text Available Osteoporosis is a major health problem, especially in elderly populations, and is associated with fragility fractures at the hip, spine, and wrist. Hip fracture contributes to both morbidity and mortality in the elderly. The demographics of world populations are set to change, with more elderly living in developing countries, and it has been estimated that by 2050 half of hip fractures will occur in Asia. This review conducted using the PubMed database describes the incidence of hip fracture in different regions of the world and discusses the possible causes of this wide geographic variation. The analysis of data from different studies show a wide geographic variation across the world, with higher hip fracture incidence reported from industrialized countries as compared to developing countries. The highest hip fracture rates are seen in North Europe and the US and lowest in Latin America and Africa. Asian countries such as Kuwait, Iran, China, and Hong Kong show intermediate hip fracture rates. There is also a north-south gradient seen in European studies, and more fractures are seen in the north of the US than in the south. The factors responsible of this variation are population demographics (with more elderly living in countries with higher incidence rates and the influence of ethnicity, latitude, and environmental factors. The understanding of this changing geographic variation will help policy makers to develop strategies to reduce the burden of hip fractures in developing countries such as India, which will face the brunt of this problem over the coming decades.

  13. Osteoarthritis of the hip and acetabular dysplasia.

    OpenAIRE

    Croft, P.; Cooper, C.; Wickham, C; Coggon, D

    1991-01-01

    The relation between acetabular dysplasia and osteoarthritis of the hip was examined in a series of 1516 pelvic radiographs taken for non-skeletal indications. Osteoarthritis was assessed by measuring joint space, and dysplasia by the centre-edge angle and acetabular depth. In contrast with previous studies of patients with symptomatic osteoarthritis of the hip, no evidence that dysplasia predisposes to osteoarthritis was found. Possible reasons for the discrepancy are discussed. It was concl...

  14. Painful Spastic Hip Dislocation: Proximal Femoral Resection

    OpenAIRE

    Albiñana, Javier; Gonzalez-Moran, Gaspar

    2002-01-01

    The dislocated hip in a non-ambulatory child with spastic paresis tends to be a painful interference to sleep, sitting upright, and perineal care. Proximal femoral resection-interposition arthroplasty is one method of treatment for this condition. We reviewed eight hips, two bilateral cases, with a mean follow-up of 30 months. Clinical improvement was observed in all except one case, with respect to pain relief and sitting tolerance. Some proximal migration was observed in three cases, despit...

  15. Neurofibromatosis induced hip arthritis. An unusual presentation

    OpenAIRE

    Alrumaih, Husam; Ilyas, Imran; Kashif, Syed

    2014-01-01

    Patient: Male, 43 Final Diagnosis: Neurofibromatosis Symptoms: Hip pain Medication: — Clinical Procedure: — Specialty: Orthopedics and Traumatology Objective: Rare disease Background: Neurofibromatosis type 1 is a disease known for orthopedic manifestations such as spine deformities, congenital pseudarthrosis of the tibia and other bony dysplasias; joint dislocations are rare. Joint arthritis caused by neurofibromatosis, with a stable hip, has never been reported in the English literature bef...

  16. MR imaging of the hip

    International Nuclear Information System (INIS)

    Full text: MRI has been shown to gain increasing importance in recent years in the evaluation of disorders of the hip and pelvis. Nowadays, conventional or fast spin echo (T1, Turbo (Fast) T2 (or PD)) MR imaging sequences are used most commonly to examine the hip and pelvis. Three dimensional (3D) gradient echo (GE) imaging allows acquisition of very thin (1 mm) sections. MR imaging with fat suppression technique (STIR, TIRM, FAT SAT T2) represent an effective screening technique for the assessment of fluid, hemorrhage, pus, or tumor in the marrow, joint or soft tissues. These techniques increase the sensitivity for the detection of a variety of pathologic processes. Fat suppression MR imaging, when combined with intravenous (or intraarticular) administration of a gadolinium compound, also is effective and often is employed when evaluating neoplastic or infectious diseases (intravenous injection), abnormalities of articular cartilage or labrum, or possible intraarticular osteocartilaginous bodies (intraarticular injection). A lesion of the acetabular labrum based is one cause of chronic hip pain in patients with developmental dysplasia of the hips, as well as in patients with a history of hip trauma or femoroacetabular impingement. MR imaging and, in particular, MR arthrography, however, have been shown to be highly accurate in the detection of subtle intraarticular abnormalities such as labral lesion. Conventional MR imaging has shown poor accuracy in detecting labral lesions, due to its inability to depict small tears and the difficulty in determining if intralabral signal abnormalities extend to the surface of the labrum. MR arthrography, however has been shown to overcome these difficulties and to have excellent accuracy in detecting labral pathology. As labral abnormalities are believed to be a precursor of osteoarthritis, orthopedic surgeons believe that surgical intervention will be influenced substantially by the type, extension and location of labral

  17. Diagnosis of infection after total hip arthroplasty

    International Nuclear Information System (INIS)

    Forty-eight total hip arthroplasties for which revision surgery was performed were reviewed to determine the accuracy of laboratory tests, plain radiographs, hip aspiration, and technetium-99m MDP and gallium-67 scans in demonstrating the presence or absence of infection of the prosthesis. Six of the 48 hips were diagnosed as having an infection at the revision surgery. The erythrocyte sedimentation rate and the C-reactive protein levels were significantly higher in the patients with infected prostheses. The difference in the white blood cell count was not significant. There was no significant relationship between the presence of infection and the severity of loosening and instability of the implants diagnosed by plain radiographs. The accuracy of hip aspiration in diagnosing the infection was 83%, with a sensitivity of 40% and a specificity of 92%. The accuracy of technetium-99m MDP bone scan was 79%, with a sensitivity of 83%, and a specificity of 79%. Gallium-67 scan had an accuracy of 96%, a sensitivity of 67%, and a specificity of 100%. The findings in the present study indicated that diagnostic tests consisting of laboratory tests and plain radiography, followed by hip aspiration and sequential use of technetium-99m MDP and gallium-67 scintigraphies, are suitable for differentiation between mechanical loosening and infection of total hip arthroplasty. (author)

  18. Artificial ecosystem selection.

    Science.gov (United States)

    Swenson, W; Wilson, D S; Elias, R

    2000-08-01

    Artificial selection has been practiced for centuries to shape the properties of individual organisms, providing Darwin with a powerful argument for his theory of natural selection. We show that the properties of whole ecosystems can also be shaped by artificial selection procedures. Ecosystems initiated in the laboratory vary phenotypically and a proportion of the variation is heritable, despite the fact that the ecosystems initially are composed of thousands of species and millions of individuals. Artificial ecosystem selection can be used for practical purposes, illustrates an important role for complex interactions in evolution, and challenges a widespread belief that selection is most effective at lower levels of the biological hierarchy. PMID:10890915

  19. Developing Creativity: Artificial Barriers in Artificial Intelligence

    OpenAIRE

    Jennings, Kyle E.

    2010-01-01

    The greatest rhetorical challenge to developers of creative artificial intelligence systems is convincingly arguing that their software is more than just an extension of their own creativity. This paper suggests that “creative autonomy,” which exists when a system not only evaluates creations on its own, but also changes its standards without explicit direction, is a necessary condition for making this argument. Rather than requiring that the system be hermetically sealed to avoid perceptions...

  20. HIP HOP for HIV Awareness: Using Hip Hop Culture to Promote Community-Level HIV Prevention

    Science.gov (United States)

    Hill, Mandy J.; Hallmark, Camden J.; McNeese, Marlene; Blue, Nike; Ross, Michael W.

    2014-01-01

    The goal of this paper was to determine the effectiveness of the HIP HOP for HIV Awareness intervention, an innovative model utilising an exchange of an HIV test for a hip hop concert ticket, in a metropolitan city among African American youth and young adults. A subset of intervention participants participated in standardised testing, sex…

  1. Influence of hip dysplasia on the development of osteoarthritis of the hip

    NARCIS (Netherlands)

    A.M. Lievense (Annet); S.M. Bierma-Zeinstra (Sita); A.P. Verhagen (Arianne); J.A.N. Verhaar (Jan); B.W. Koes (Bart)

    2004-01-01

    textabstractBACKGROUND: It has been suggested that in some patients with primary hip osteoarthritis (OA), the disease occurs as a consequence of acetabular dysplasia or hip dysplasia (HD). OBJECTIVE: To carry out a systematic review to investigate the association between acetabular

  2. Hip Reconstruction Osteotomy by Ilizarov Method as a Salvage Option for Abnormal Hip Joints

    Directory of Open Access Journals (Sweden)

    Masood Umer

    2014-01-01

    Full Text Available Hip joint instability can be secondary to congenital hip pathologies like developmental dysplasia (DDH or acquired such as sequel of infective or neoplastic process. An unstable hip is usually associated with loss of bone from the proximal femur, proximal migration of the femur, lower-extremity length discrepancy, abnormal gait, and pain. In this case series of 37 patients coming to our institution between May 2005 and December 2011, we report our results in treatment of unstable hip joint by hip reconstruction osteotomy using the Ilizarov method and apparatus. This includes an acute valgus and extension osteotomy of the proximal femur combined with gradual varus and distraction (if required for realignment and lengthening at a second, more distal, femoral osteotomy. 18 males and 19 females participated in the study. There were 17 patients with DDH, 12 with sequelae of septic arthritis, 2 with tuberculous arthritis, 4 with posttraumatic arthritis, and 2 with focal proximal femoral deficiency. Outcomes were evaluated by using Harris Hip Scoring system. At the mean follow-up of 37 months, Harris Hip Score had significantly improved in all patients. To conclude, illizarov hip reconstruction can successfully improve Trendelenburg’s gait. It supports the pelvis and simultaneously restores knee alignment and corrects lower-extremity length discrepancy (LLD.

  3. Hip reconstruction osteotomy by Ilizarov method as a salvage option for abnormal hip joints.

    Science.gov (United States)

    Umer, Masood; Rashid, Haroon; Umer, Hafiz Muhammad; Raza, Hasnain

    2014-01-01

    Hip joint instability can be secondary to congenital hip pathologies like developmental dysplasia (DDH) or acquired such as sequel of infective or neoplastic process. An unstable hip is usually associated with loss of bone from the proximal femur, proximal migration of the femur, lower-extremity length discrepancy, abnormal gait, and pain. In this case series of 37 patients coming to our institution between May 2005 and December 2011, we report our results in treatment of unstable hip joint by hip reconstruction osteotomy using the Ilizarov method and apparatus. This includes an acute valgus and extension osteotomy of the proximal femur combined with gradual varus and distraction (if required) for realignment and lengthening at a second, more distal, femoral osteotomy. 18 males and 19 females participated in the study. There were 17 patients with DDH, 12 with sequelae of septic arthritis, 2 with tuberculous arthritis, 4 with posttraumatic arthritis, and 2 with focal proximal femoral deficiency. Outcomes were evaluated by using Harris Hip Scoring system. At the mean follow-up of 37 months, Harris Hip Score had significantly improved in all patients. To conclude, illizarov hip reconstruction can successfully improve Trendelenburg's gait. It supports the pelvis and simultaneously restores knee alignment and corrects lower-extremity length discrepancy (LLD). PMID:24895616

  4. Principles of artificial intelligence

    CERN Document Server

    Nilsson, Nils J

    1980-01-01

    A classic introduction to artificial intelligence intended to bridge the gap between theory and practice, Principles of Artificial Intelligence describes fundamental AI ideas that underlie applications such as natural language processing, automatic programming, robotics, machine vision, automatic theorem proving, and intelligent data retrieval. Rather than focusing on the subject matter of the applications, the book is organized around general computational concepts involving the kinds of data structures used, the types of operations performed on the data structures, and the properties of th

  5. Intelligence: Real or artificial?

    OpenAIRE

    Schlinger, Henry D

    1992-01-01

    Throughout the history of the artificial intelligence movement, researchers have strived to create computers that could simulate general human intelligence. This paper argues that workers in artificial intelligence have failed to achieve this goal because they adopted the wrong model of human behavior and intelligence, namely a cognitive essentialist model with origins in the traditional philosophies of natural intelligence. An analysis of the word “intelligence” suggests that it originally r...

  6. Artificial Personality and Disfluency

    OpenAIRE

    Wester, Mirjam; Aylett, Matthew; Tomalin, Marcus; Dall, Rasmus

    2015-01-01

    The focus of this paper is artificial voices with different personalities. Previous studies have shown links between an individual's use of disfluencies in their speech and their perceived personality. Here, filled pauses (uh and um) and discourse markers (like, you know, I mean) have been included in synthetic speech as a way of creating an artificial voice with different personalities. We discuss the automatic insertion of filled pauses and discourse markers (i.e., fillers) into otherwise f...

  7. The Artificial Anal Sphincter

    OpenAIRE

    Christiansen, John

    2000-01-01

    The artificial anal sphincter as treatment for end stage anal incontinence was first described in 1987. Published series concern a total of 42 patients, with a success rate of approximately 80%. Infection has been the most serious complication, but a number of technical complications related to the device have also occurred and required revisional procedures in 40% to 60% of the patients. The artificial anal sphincter may be used for the same indications as dynamic graciloplasty except in pat...

  8. ELIGIBILITY FOR THE HIP-RESURFACING ARTHROPLASTY PROCEDURE: AN EVALUATION ON 592 HIPS

    Science.gov (United States)

    Queiroz, Roberto Dantas; Faria, Rafael Salomon Silva; Duarte, David Marcelo; Takano, Marcelo Itiro; Sugiyama, Mauricio Morita

    2015-01-01

    Objective: To investigate the percentage of ideal patients who would be eligible for hip-resurfacing surgery at a reference service for hip arthroplasty. Methods: Out of all the cases of hip arthroplasty operated at Hospital do Servidor Público Estadual de São Paulo (HSPE) between January 2009 and December 2010, we assessed a total of 592 procedures that would fit the criteria for indication for resurfacing arthroplasty, after clinical and radiological evaluation according to the criteria established by the Food and Drug Administration (FDA) and by Seyler et al. Results: Among the total number of hip replacement arthroplasty cases, 5.74% of the patients were eligible. Among the patients who underwent primary arthroplasty, we found that 8.23% presented ideal conditions for this procedure. Conclusion: The study demonstrated that this type of surgery still has a limited role among hip surgery methods. PMID:27047851

  9. Isokinetic performance of hip muscles after revision total hip arthroplasty via previous anterolateral approach.

    Science.gov (United States)

    Cankaya, Deniz; Aydin, Cemal; Karakus, Dilek; Toprak, Ali; Ozkurt, Bulent; Tabak, Yalçın

    2015-09-01

    We investigated the isokinetic performance of hip muscles and clinical outcomes after revision total hip arthroplasty (THA) via same anterolateral approach used in primary surgery. Thirty patients who had undergone previous THA via an anterolateral approach underwent both acetabular and femoral component revision after aseptic loosening. The Harris Hip Score (HHS) was evaluated during a minimum 2-year follow-up. The isokinetic muscle strength of the operated and nonoperated hips was assessed 1 year after surgery. The HHS improved from 49.0 to 77.4. Operated and nonoperated hips exhibited similar isokinetic performance during all measurements (flexion, extension, and abduction) (p>0.05). This prospective study showed that the anterolateral approach preserves abductor strength after revision THA in aseptic cases with acceptable functional and clinical results. The main clinical relevance of this study is that the same anterolateral approach used in previous primary THA is also safe and viable for revision THA. PMID:26435233

  10. Artificial skin. Jinko hifu

    Energy Technology Data Exchange (ETDEWEB)

    Kifune, K. (Unitika Ltd., Osaka (Japan))

    1993-06-15

    In order to restore the human skin wounds, the transplantation is only one measure. The transplantation can take only when own skin is used, and there is no successful example by using other person's skin. When the own skin is not sufficient due to the too vast damage, the artificial skin, which can be regenerated as it is, is required. The artificial skin is said to be the most difficult organ among the artificial organs, even though its function is quite simple. Although there are the pig skin, the collagen membrane and the synthetic materials such as the polyurethane and so forth, as the materials similar to the artificial skin, they cover the wounds just until the cuticle is formed. Recently there is a cultivated skin. Firstly the normal skin with a size of the stamp is cut off, and then the cuticle cells are taken to pieces and cultivated, and consequently it is possible to increase the area by several 10 times. In addition, there is also a trial to make the artificial skin synthetically. Its upper layer is composed of the silicon, and the lower layer is the collagen membrane with a sponge structure. The silicon, membrane can be said to be an ideal artificial skin, because it detaches naturally. The chitin, which has recently appeared as the wound protection material, is also the promising material. 3 figs.

  11. RAZVOJ OBLAČIL V HIP HOP KULTURI

    OpenAIRE

    Marić, Sanja

    2010-01-01

    V diplomskem delu smo raziskovali, kako so se hip hop oblačila razvijala skozi obdobja v hip hop kulturi. V teoretičnem deli smo ugotavljali ozadje in dejavnike, ki so vplivali na razvoj hip hop kulture, v empiričnem delu diplomske naloge pa smo izvedli anketni vprašalnik z glavnimi akterji hip hop kulture na slovenski hip hop sceni. Rezultati, ki smo jih dobili, kažejo da so imela oblačila velik vpliv na prepoznavnost in razvoj hip hop kulture po celem svetu. K temu so največ pripomogli ustv...

  12. Magnetic resonance imaging of hip joint cartilage and labrum

    Directory of Open Access Journals (Sweden)

    Christoph Zilkens

    2011-09-01

    Full Text Available Hip joint instability and impingement are the most common biomechanical risk factors that put the hip joint at risk to develop premature osteoarthritis. Several surgical procedures like periacetabular osteotomy for hip dysplasia or hip arthroscopy or safe surgical hip dislocation for femoroacetabular impingement aim at restoring the hip anatomy. However, the success of joint preserving surgical procedures is limited by the amount of pre-existing cartilage damage. Biochemically sensitive MRI techniques like delayed Gadolinium Enhanced MRI of Cartilage (dGEMRIC might help to monitor the effect of surgical or non-surgical procedures in the effort to halt or even reverse joint damage.

  13. Arthroscopic management of an intraarticular osteochondroma of the hip

    Directory of Open Access Journals (Sweden)

    Brian T. Feeley

    2009-04-01

    Full Text Available The role of hip arthroscopy in the management of femoroacetabular impingement (FAI has been advancing rapidly. In this case report, we describe the use of hip arthroscopy to successfully treat a femoral neck osteochondroma that caused a symptomatic labral tear in a 37 year old woman. Hip arthroscopy offers several advantages to surgical dislocation of the hip in the management of intra articular pathology and FAI. Hip arthroscopy is minimally invasive without the significant trauma to hip musculature, is useful in treatment of labral tears generated by FAI, and can be used to resect small lesions on the femoral head.

  14. MR arthrography of the hip joint

    International Nuclear Information System (INIS)

    MR arthrography of the hip joint is usually performed after a conventional MRI has been obtained to rule out other pathologies of the hip joint as for instance bone marrow edema or osteonecrosis of the hip. MR arthrography is mainly performed as a very special investigation, and it is executed in most cases if the clinician asks for the diagnosis of a labral lesion. In very rare cases, MR arthrography of the hip is performed to image cartilage disease or osteochondrosis dissecans or free intraarticular bodies. In this paper, the indications, the technique, and the most important pathology of the hip joint - labral lesions - will be described as well as variants of the normal acetabular labrum. After a conventional MRI of the hip joint has been performed, a MR arthrography of the hip will be obtained to search for labral pathology or cartilage disease. MR arthrography is obtained after the intraarticular injection of 10-20 ml of a 0.1 mmol solution of gadopentate-dimeglumine has been performed. The intraarticular injection can either be fluoroscopic-guided or CT-guided or directly MR-guided. After the intraarticular injection, MR arthrography will be performed by the use of paracoronal and parasagittal T1-weighted spin echo or gradient echo sequences. In cases of labral lesions (degeneration, labral tear, labral detachment) or cartilage disease MR arthrography proved to be more sensitive as conventional MRI as shown in the literature. The sensitivity of MRI to detect labral pathology was reported to be about 65%, and that of MR arthrography was reported to be about 92-95% compared to surgical results. According to the current literature, MR arthrography is the most sensitive method to delineate these kind of pathologies. Therefore, the invasive technique of MR arthrography may be justified for the correct diagnosis of these kind of pathologies after other pathologic entities have been ruled out by conventional MRI. (orig.)

  15. The strength and function of hip abductors following anterolateral minimally invasive total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Tan Jixiang

    2014-04-01

    Full Text Available Objective: To analyze the extent of postoperative hip abductor insufficiency in primary total hip arthroplasty (THA patients undergoing anterolateral minimally invasive (ALMI approach, and to investigate whether the clinical outcomes are more favorable in femoral neck fracture (FNF patients than in non-femoral neck fracture (nFNF patients. Methods:A total of 48 patients were enrolled in this study. Each patient underwent a clinical examination preoperatively and 6, 12, 24 and 48 weeks postoperatively. The abductor torque, Trendelenburg's sign, gait velocity, Harris hip score, Oxford hip score, Westren Ontario and McMaster Universities (WOMAC score and visual analog scale pain score were recorded. Statistical evaluation was performed with SPSS software version 18.0. The significance level was set at P<0.05. Results:The abductor torque of the operated hip and the recovery ratio showed a gradual improving tendency from 6 weeks postoperatively until the last follow-up. Gait velocity, Harris hip score, Oxford hip score and WOMAC score improved significantly after the operation until 24 weeks postoperatively. In the FNF group, the abductor torque of the operated side and the recovery ratio were significantly higher than in nFNF group at 6 weeks postoperatively, however, as time passed, this trend tended to disappear. Conclusion:This study demonstrates that patients can obtain good abductor strength and function in the early postoperative period and the hip abductor function of patients who suffer from hip osteoarthritis, rheumatoid arthritis, avascular necrosis of the femoral head could be significantly improved following ALMI THA. Key words: Arthroplasty, replacement, hip; Surgical procedures, minimally invasive; Recovery of function

  16. Ability of lower teardrop edge to restore anatomical hip center height in total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    Lu Yufeng; Cheng Liming; Guo Wanshou; Yu Qingsheng; Gao Fuqiang; Zhang Qidong; Liu Zhaohui

    2014-01-01

    Background The acetabular teardrop is often used to guide acetabular component placement in total hip arthroplasty (THA).Placing the lower acetabular component aspect at the same level as the lower teardrop edge was assumed to restore the hip center of rotation.Here we radiographically analyzed the relationship between cup center and normal contralateral acetabulum center height on unilateral THA using this placement method.Methods A total of 106 unilateral THA cases with normal contralateral acetabula were reviewed and the vertical and horizontal distances in relation to the lower acetabular teardrop edge from both hip joint centers,cup inclination,and anteversion were measured radiographically.The paired t-test was used to compare left and right hip center heights.Scatter plots and Pearson's correlation coefficients were used to evaluate differences in hip center heights,cup anteversion,inclination angles,and medialized cup center distance compared to the contralateral hip joint.Results Cup center height was significantly greater (P <0.01) than contralateral hip joint center height (93.4% in the 0-5 mm range,6.6% >5 mm).There was a weak correlation between hip center height difference and inclination (r=0.376,P <0.01) and between difference and anteversion (r=0.310,P <0.01) but no correlation between difference and outer cup diameter (r=0.184,P=0.058) or difference and medialized cup center distance (r=-0.098,P=0.318).Conclusions Although this method did not exactly replicate anatomic hip center height,the clinical significance of cup center height and anatomic hip center height differences is negligible.This acetabular component placement method has high simplicity,reliability,and stability.

  17. "Doctor-nurse integration"management in the prevention of Deep Vein Thrombosis in patients underwent artificial total hip replacement%医护一体化管理降低人工髋关节置换术患者深静脉血栓发生率的实践

    Institute of Scientific and Technical Information of China (English)

    姜香云; 吴佳倩; 张亚珥; 冯志仙

    2014-01-01

    目的:探讨医护一体化管理降低人工髋关节置换术后深静脉血栓(DVT)发生率的成效。方法:成立医护一体化专项管理小组,制定医护一体化管理流程,分析人工髋关节置换术所致深静脉血栓发生原因并提出对策,医护人员共同参与培训学习,明确责任,共同监督、协作、反馈、持续改进。对比分析实施医护一体化管理前后人工髋关节置换术患者DV T的发生率。结果:实施前髋关节置换术患者DVT发生率为42.1%,经两轮持续质量改进,DVT发生率降低至17.3%,实施前后比较差异有统计学意义(P<0.01)。结论:医护一体化管理可降低人工髋关节置换术患者DVT的发生率,从而提升医疗护理质量。%Objective:To assess the efficacy of"doctor-nurse integration"management in the prevention of Deep Vein Thrombosis (DVT) in patients underwent total hip replacement (THA) surgery. Methods:A"doctor-nurse integration"team was established to investigate the incidence rate of DVT, the proper use of administration of anti-clotting drug, and the rate of intermittent pneumatic compression pump (IPCP) application in patients who underwent THA between January and March in 2013. The team analyzed possible causes of DVT to develop a standard process for the prevention of DVT after THA. The nurses and physicians were trained together to specify their own responsibilities, with substantial interactions, such as co-supervision, co-operation, and in time feedbacks. The pattern of"doctor-nurse integration"was carried out together with physical therapists. The incidence rate of DVT was measured before and after the application of"doctor-nurse integration"management for analysis. Results:After two-round improvements, the incidence rate of DVT in patients underwent THA decreased from 42.1%to 17.3%(P<0.01). Conclusion:The pattern of"doctor-nurse integration"could signiifcantly decrease the incidence of DVT in patients who had

  18. Development and Physical Control Research on Prototype Artificial Leg

    Directory of Open Access Journals (Sweden)

    Fei Li

    2016-03-01

    Full Text Available To provide an ideal platform for research on intelligent bionic leg (IBL, this paper proposes a model of a biped robot with heterogeneous legs (BRHL. A prototype of an artificial leg is developed based on biological structure and motion principle analysis of human lower extremities. With regard to the driving sources, servomotors are chosen for the hip joint and ankle joint, while pneumatic muscle actuators (PMAs are chosen for the knee joint. The control system of the bionic artificial leg is designed and a physical experimental platform is established. The physical control experiments are done based on proportional-integral-derivative (PID control strategy. The experimental results show that such a system can realize the expected goals.

  19. Short time-frame from first to second hip fracture in the Funen County Hip Fracture Study

    DEFF Research Database (Denmark)

    Nymark, T; Lauritsen, Jens; Ovesen, O; Röck, N D; Jeune, B

    2006-01-01

    Hip fracture patients represent a frail group of elderly with increased morbidity and mortality. The aim of this study was to evaluate the occurrence and distribution of a second hip fracture in the time interval between the first and the second hip fracture.......Hip fracture patients represent a frail group of elderly with increased morbidity and mortality. The aim of this study was to evaluate the occurrence and distribution of a second hip fracture in the time interval between the first and the second hip fracture....

  20. Instrumented hip implants: electric supply systems.

    Science.gov (United States)

    Soares dos Santos, Marco P; Ferreira, Jorge A F; Ramos, A; Simões, José A O; Morais, Raul; Silva, Nuno M; Santos, Paulo M; Reis, M J C S; Oliveira, T

    2013-10-18

    Instrumented hip implants were proposed as a method to monitor and predict the biomechanical and thermal environment surrounding such implants. Nowadays, they are being developed as active implants with the ability to prevent failures by loosening. The generation of electric energy to power active mechanisms of instrumented hip implants remains a question. Instrumented implants cannot be implemented without effective electric power systems. This paper surveys the power supply systems of seventeen implant architectures already implanted in-vivo, namely from instrumented hip joint replacements and instrumented fracture stabilizers. Only inductive power links and batteries were used in-vivo to power the implants. The energy harvesting systems, which were already designed to power instrumented hip implants, were also analyzed focusing their potential to overcome the disadvantages of both inductive-based and battery-based power supply systems. From comparative and critical analyses of the methods to power instrumented implants, one can conclude that: inductive powering and batteries constrain the full operation of instrumented implants; motion-driven electromagnetic energy harvesting is a promising method to power instrumented passive and active hip implants. PMID:24050511

  1. Screening for congenital dislocation of the hip

    International Nuclear Information System (INIS)

    Although the prevalence of (idiopathic) congenital dislocation of the hip (CDH) within the Member States of the European Community is not exactly known, it must be considered as a major problem of public health care and protection. By assessment of available data one can assume that between 1 and 2% of all newborns have dislocation or instability of one or both hips. There is a female predominance of 4:1 and some risk factors are known. The reasons of a higher prevalence in some areas are not yet well understood. Most of instable hips will spontaneously become stable within the first days or weeks of life. However, a considerable number of infants (less than 1%) will remain with instable hips which may dislocate. Dislocation either present at birth or as a result of persistent instability leads to subsequent hip deformation. This is a serious event for each affected individual, and is a heavy load on health care and social costs for the public. Treatment of CDH is easy and usually effective when started early, i.e. before the fourth month of life. The earlier treatment is started the easier, shorter, safer and less expensive it is and its impairment on child development and mother-child interaction can be held to a minimum. Screening for CDH is therefore the most important part of health protection in early infancy. However, this paper concludes that neither sonography nor X-ray examinations are appropriate for CDH screening

  2. Getting Active After Knee Replacement Might Raise Hip Fracture Risk

    Science.gov (United States)

    ... exact reason for the increase in hip and spine fractures isn't clear, it's most likely due "to ... Osteoporosis International . "The increasing risk for hip and vertebral fracture in the 10 years after knee replacement may ...

  3. After Hip Replacement, Therapy At Home May Be Enough

    Science.gov (United States)

    ... nih.gov/medlineplus/news/fullstory_157609.html After Hip Replacement, Therapy at Home May Be Enough Finding ... Surgeons often recommend outpatient physical therapy to help hip replacement patients get moving again, but researchers report ...

  4. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... to review: a small-incision hip replacement still uses the traditional high-speed hip replacement parts. The ... Austin. The -- it starts with the anesthesiologist. We use spinal anesthesia, which has been strongly demonstrated -- or, ...

  5. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... Jefferson University Hospital specializing in hip and knee joint replacement. And today with me I have Dr. ... bandaged up. The yellow material covers the hip joint. I’m standing there to the right on ...

  6. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... more slides, talking about some of the clinical issues. And again, the results of hip resurfacing have ... in the first three years. There are still issues of how long a hip resurfacing is going ...

  7. The prevalence of predisposing deformity in osteoarthritic hip joints

    DEFF Research Database (Denmark)

    Klit, Jakob; Gosvig, Kasper; Jacobsen, Steffen; Sonne-Holm, Stig; Troelsen, Anders

    2011-01-01

    population-based database of 4151 individuals, all of whom had a standard anteroposterior weight-bearing pelvic radiograph taken. Hip joints were classified according to type and degree of deformity. We defined hip osteoarthritis by a minimum joint space width of hips and 173 left hips) and 162 males (77 right hips and 85 left hips) with osteoarthritis. We found an overall prevalence of predisposing hip deformities in...... females of 62.4% and in males of 78.9%. Minor and major deformities showed the same prevalence. Both sexes had a comparable prevalence of minor and major hip joint deformity, except for pistol grip deformity, which was more prevalent in men. We concluded that 'idiopathic osteoarthritis' is uncommon, and...

  8. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... incision hip replacement still uses the traditional high-speed hip replacement parts. The metal stem is made ... a special instrument; here’s an instrument that has light attached to it. So there with my probe ...

  9. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... special beds. We compared this traditional hip precaution group to a group which did not require these hip precautions. We found, in fact, no significant difference between either group, and this has allowed us to scientifically do ...

  10. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... Thomas Jefferson University Hospital specializing in hip and knee joint replacement. And today with me I have ... University Hospital who also specializes in hip and knee replacement surgery. For our viewers, I would like ...

  11. Hip or knee replacement - after - what to ask your doctor

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000232.htm Hip or knee replacement - after - what to ask your doctor To ... had surgery to get a new hip or knee joint while you were in the hospital. Below ...

  12. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... them. Traditional total hip arthroplasty, in some people’s minds, does not provide enough for the patient; patients ... patients qualify for hip resurfacing, and would you mind recapping on again, who is a candidate for ...

  13. Hip or knee replacement - after - what to ask your doctor

    Science.gov (United States)

    ... Below are some questions you may want to ask your health care provider to help you take ... What to ask your doctor after hip or knee replacement; Hip replacement - after - what to ask your doctor; Knee replacement - after - ...

  14. HIP technologies for fusion reactor blankets fabrication

    International Nuclear Information System (INIS)

    The benefit of HIP techniques applied to the fabrication of fusion internal components for higher performances, reliability and cost savings are emphasized. To demonstrate the potential of the techniques, design of new blankets concepts and mock-ups fabrication are currently performed by CEA. A coiled tube concept that allows cooling arrangement flexibility, strong reduction of the machining and number of welds is proposed for ITER IAM. Medium size mock-ups according to the WCLL breeding blanket concept have been manufactured. The fabrication of a large size mock-up is under progress. These activities are supported by numerical calculations to predict the deformations of the parts during HIP'ing. Finally, several HIP techniques issues have been identified and are discussed

  15. [Hip ultrasound evaluation in infancy: comparison with normal results].

    Science.gov (United States)

    Russo, E M; Lusenti, A

    2003-01-01

    We have reviewed more than a decade of clinical-echographical research in the developmental displasia of the hip (D.D.H.). We have examined 2050 small patients aged less than three months, with normal hips, and evaluated a number of ultrasound parameters that, in our opinion, may be helpful to give a description of hips particularly precise. We clearly underline that a precise definition, as more as possible, is a starting point to study all the pathological hips. PMID:15070268

  16. Effect of increased pushoff during gait on hip joint forces

    OpenAIRE

    Lewis, Cara L.; Garibay, Erin J.

    2014-01-01

    Anterior acetabular labral tears and anterior hip pain may result from high anteriorly directed forces from the femur on the acetabulum. While providing more pushoff is known to decrease sagittal plane hip moments, it is unknown if this gait modification also decreases hip joint forces. The purpose of this study was to determine if increasing pushoff decreases hip joint forces. Nine healthy subjects walked on an instrumented force treadmill at 1.25 m/s under two walking conditi...

  17. Hip adduction and abduction strength profiles in elite soccer players

    DEFF Research Database (Denmark)

    Serner, Andreas; Petersen, Jesper; Madsen, Thomas Moller;

    2011-01-01

    An ipsilateral hip adduction/abduction strength ratio of more than 90%, and hip adduction strength equal to that of the contralateral side have been suggested to clinically represent adequate strength recovery of hip adduction strength in athletes after groin injury. However, to what extent side-......-to-side symmetry in isometric hip adduction and abduction strength can be assumed in soccer players remains uncertain....

  18. Frequency of Developmental Hip Dysplasia in a Training Hospital

    OpenAIRE

    Emrah Can; İlhan Asya Tanju; Cihan Meral

    2010-01-01

    Aim: We aimed to determine the frequency of cases with developmental hip dysplasia during the neonatal period and the associated risk factors. Methods: Hip ultrasound images of 258 full-term newborns aged one month were evaluated prospectively in conjunction with physical examination for developmental hip dysplasia in GATA well baby outpatient clinic. Results: The incidence of developmental hip dysplasia was 0.3% in one-month-old, healthy, full-term babies included in ...

  19. Rehabilitation following hip arthroscopy - A systematic review

    Directory of Open Access Journals (Sweden)

    Jeffrey S Grzybowski

    2015-05-01

    Full Text Available CONTEXT: Rehabilitation following hip arthroscopy is an integral component of the clinical outcome of the procedure. Given the increase in quantity, complexity, and diversity of procedures performed, a need exists to define the role of rehabilitation following hip arthroscopy.OBJECTIVES: 1 To determine the current rehabilitation protocols utilized following hip arthroscopy in the current literature, 2 to determine if clinical outcomes are significantly different based on different post-operative rehabilitation protocols; and 3 to propose the best-available evidence-based rehabilitation program following hip arthroscopy.DATA SOURCES: Per PRISMA guidelines and checklist, Medline, SciVerse Scopus, SportDiscus, and Cochrane Central Register of Controlled Trials were searched.STUDY SELECTION: Level I-IV evidence clinical studies with minimum two-year follow-up reporting outcomes of hip arthroscopy with post-operative rehabilitation protocols described were included. DATA EXTRACTION: All study, subject, and surgery parameters were collected. All elements of rehabilitation were extracted and analyzed. Descriptive statistics were calculated. Study methodological quality was analyzed using the Modified Coleman Methodology Score (MCMS.RESULTS: 18 studies were included (2,092 subjects; 52% male, mean age 35.1 +/- 10.6 years, mean follow-up 3.2 +/- 1.0 years. Labral tear and femoroacetabular impingement were the most common diagnoses treated and labral debridement and femoral/acetabular osteochondroplasty the most common surgical techniques performed. Rehabilitation protocol parameters (weight-bearing, motion, strengthening, and return-to-sport were poorly reported. Differences in clinical outcomes were unable to be assessed given heterogeneity in study reporting. Time-, phase-, goal-, and precaution-based guidelines were extracted and reported.CONCLUSIONS: The current literature of hip arthroscopy rehabilitation lacks high-quality evidence to support a

  20. Artificial intelligence in nanotechnology

    International Nuclear Information System (INIS)

    During the last decade there has been increasing use of artificial intelligence tools in nanotechnology research. In this paper we review some of these efforts in the context of interpreting scanning probe microscopy, the study of biological nanosystems, the classification of material properties at the nanoscale, theoretical approaches and simulations in nanoscience, and generally in the design of nanodevices. Current trends and future perspectives in the development of nanocomputing hardware that can boost artificial-intelligence-based applications are also discussed. Convergence between artificial intelligence and nanotechnology can shape the path for many technological developments in the field of information sciences that will rely on new computer architectures and data representations, hybrid technologies that use biological entities and nanotechnological devices, bioengineering, neuroscience and a large variety of related disciplines. (topical review)

  1. Do hip prosthesis related infection codes in administrative discharge registers correctly classify periprosthetic hip joint infection?

    DEFF Research Database (Denmark)

    Lange, Jeppe; Pedersen, Alma B; Troelsen, Anders;

    2015-01-01

    PURPOSE: Administrative discharge registers could be a valuable and easily accessible single-sources for research data on periprosthetic hip joint infection. The aim of this study was to estimate the positive predictive value of the International Classification of Disease 10th revision (ICD-10...... decreased to 82% (95% CI: 72-89). CONCLUSIONS: Misclassification must be expected and taken into consideration when using administrative discharge registers for epidemiological research on periprosthetic hip joint infection. We believe that the periprosthetic hip joint infection diagnosis code can be of use...... in future single-source register based studies, but preferably should be used in combination with alternate data sources to ensure higher validity....

  2. Persistently High Hip Circumference after Bariatric Surgery Is a Major Hurdle to Successful Hip Replacement

    OpenAIRE

    Menachem M. Meller; Courville, Amber B; Sumner, Anne E.

    2014-01-01

    The prevalence of class III obesity (BMI ≥ 40 kg/m2) in black women is 18%. As class III obesity leads to hip joint deterioration, black women frequently present for orthopedic care. Weight loss associated with bariatric surgery should lead to enhanced success of hip replacements. However, we present a case of a black woman who underwent Roux-en-Y gastric bypass with the expectation that weight loss would make her a better surgical candidate for hip replacement. Her gastric bypass was success...

  3. Total Hip Arthroplasty in Mucopolysaccharidosis Type IH

    Directory of Open Access Journals (Sweden)

    S. O'hEireamhoin

    2011-01-01

    Full Text Available Children affected by mucopolysaccharidosis (MPS type IH (Hurler Syndrome, an autosomal recessive metabolic disorder, are known to experience a range of musculoskeletal manifestations including spinal abnormalities, hand abnormalities, generalised joint stiffness, genu valgum, and hip dysplasia and avascular necrosis. Enzyme therapy, in the form of bone marrow transplantation, significantly increases life expectancy but does not prevent the development of the associated musculoskeletal disorders. We present the case of a 23-year-old woman with a diagnosis of Hurler syndrome with a satisfactory result following uncemented total hip arthroplasty.

  4. Preventable mortality in geriatric hip fracture inpatients

    OpenAIRE

    Tarrant, S. M.; Hardy, B. M.; Byth, P. L.; Brown, T L; Attia, J.; Balogh, Z. J.

    2014-01-01

    There is a high rate of mortality in elderly patients who sustain a fracture of the hip. We aimed to determine the rate of preventable mortality and errors during the management of these patients. A 12 month prospective study was performed on patients aged > 65 years who had sustained a fracture of the hip. This was conducted at a Level 1 Trauma Centre with no orthogeriatric service. A multidisciplinary review of the medical records by four specialists was performed to analyse errors of manag...

  5. Modes of lubrication in human hip joints.

    OpenAIRE

    Roberts, B J; Unsworth, A; Mian, N.

    1982-01-01

    Cadaveric hip joints were tested in a hip function simulator which subjected the femoral head to a cycle of loading and oscillation similar to that experienced during walking and measured the frictional torque transmitted to the acetabulum. Silicone fluids with viscosities from 10-2 Pa s (pascal second) to 30 Pa s were used as lubricants and the transition from mixed to full fluid film lubrication was observed around 5 x 10(-2) Pa s. Sodium carboxymethylcellulose solutions were also tested at...

  6. Vaginal mass following uncemented total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Young-Soo Shin

    2014-01-01

    Full Text Available A 53-year-old woman developed a vaginal mass following an uncemented total hip arthroplasty. The mass was in direct communication with the hip through an acetabular medial wall defect after loosening of the acetabular component. The mass formation was caused simultaneously by changes secondary to polyethylene wear, a tiny delamination of the porous titanium mesh coating and a broken antirotational tab on the acetabular cup, all of which may have served as sources of metal particles. A careful evaluation of the patient′s history, symptoms, X-ray findings and computed tomography scans should always be performed to ensure accurate diagnosis.

  7. Biomimetic Composite-Metal Hip Resurfacing Implant

    OpenAIRE

    Habiba Bougherara; Bureau, Martin N.

    2008-01-01

    Hip resurfacing technique is a conservative arthroplasty used in the young patient in which the femoral head is reshaped to accept metal cap with small guide stem. In the present investigation, a hybrid composite-metal resurfacing implant is proposed. The cup is made of carbon fiber/polyamide 12 (CF/PA12) covered with a thin layer of cobalt chrome (Co-Cr). Finite element (FE) method was applied to analyze and compare the biomechanical performances of the hybrid hip resurfacing (HHR) and the c...

  8. Vascular injuries during total hip revision

    International Nuclear Information System (INIS)

    Although most patients undergoing a revision total hip replacement (THR) will have an uneventful procedure, in others the potential of serous vascular injuries is real. Migrating prosthesis or excessive cement may be in compromising positions adjacent or adherent to vessels and pose a particular danger at surgery with inadvertent lacerations of vessels such as the internal and external iliac arteries. In out study of 20 patients with THR, CT with two-dimensional reconstructions is used to define vessel position. In eight of these patients, the hip prosthesis or displaced cement lies within 5 mm of major vessels. In patients with dislocation of the acetabular cup, the potential of vascular injury is highest

  9. Hip pain is more frequent in severe hip displacement: a population-based study of 77 children with cerebral palsy.

    Science.gov (United States)

    Ramstad, Kjersti; Terjesen, Terje

    2016-05-01

    The aim of this study was to assess whether hip pain was associated with radiographic hip displacement (migration percentage, MP) in a population-based cohort of children with cerebral palsy. Seventy-seven children, mean age 9.5 (SD 1.6) years and Gross Motor Function Classification System level III-V, were assessed. Caregivers responded to the Child Health Questionnaire pain questions and located recurrent pain on a body map. Hip pain was reported in 22 children (29%) and 27 hips (18%). Hip pain was significantly more frequent in hips with MP more than or equal to 50%, in children with spastic quadriplegia, and in those with Gross Motor Function Classification System level V. We conclude that severe hip displacement with MP more than or equal to 50% was associated with hip pain, whereas slight or moderate subluxation did not influence the occurrence of such pain. PMID:26895291

  10. The hip trial: psychosocial consequences for mothers of using ultrasound to manage infants with developmental hip dysplasia

    OpenAIRE

    Gardner, F; Dezateux, C; ELBOURNE, D.; Gray, A; King, A; Quinn, A; on, b

    2005-01-01

    Background: The hip trial aimed to assess clinical effectiveness, economic and psychosocial costs, and benefits of ultrasound imaging (US) compared with conventional clinical assessment alone to guide the management of infants with neonatal hip instability.

  11. Hip-Hopping across China: Intercultural Formulations of Local Identities

    Science.gov (United States)

    Barrett, Catrice

    2012-01-01

    The linguistic dimensions of globalized hip-hop cannot be understood simply as a byproduct of English as an American export. As hip-hop mobilizes, it is common (and arguably necessary) for global hip-hop communities to struggle through purposeful, semiotically rooted dialectics over what constitutes "authentic" and respectable forms of local…

  12. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... what might be the best choice for them. Traditional total hip arthroplasty, in some people’s minds, does ... a small-incision hip replacement still uses the traditional high-speed hip replacement parts. The metal stem ...

  13. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... OK, so hip replacement or resurfacing, Dr. Hozack -- what percentage of your patients qualify for hip resurfacing, and would you ... of the questions I might ask you is what sort of activity am I allowed to do after hip replacement? And is the degree -- is the type and the degree of activities I do different ...

  14. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... hip joint is replaced either with metal or plastic or ceramic. But, not every patient who has arthritis of their hip needs a hip replacement. There are patients in whom the degree of arthritis is not severe enough to require replacement surgery, and these patients are candidates for what we ...

  15. Degeneration in dysplastic hips. A computer tomography study

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Rømer, Lone; Søballe, Kjeld

    2005-01-01

    -referred younger patients with hip pain believed to be caused by hip dysplasia constituted the study cohort. The average age was 35.5 years (range, 15-61 years). They were examined by close-cut transverse pelvic and knee computed tomography and antero-posterior radiographs (CT). We identified 197 hips with...

  16. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... the left, is in the patients under the age of 55. Anybody over that age, the hip replacement -- the standard type -- has better ... standard hip replacement. If you’re over the age of 60, I think a standard hip replacement, ...

  17. Perceived loading and muscle activity during hip strengthening exercises

    DEFF Research Database (Denmark)

    Brandt, Mikkel; Jakobsen, Markus Due; Thorborg, Kristian;

    2013-01-01

    OBJECTIVE: Decreased hip muscle strength is frequently reported in patients with hip injury or pathology. Furthermore, soccer players suffering from groin injury show decreased strength of hip muscles. Estimating 10-repetition maximum can be time-consuming and difficult, thus, using the Borg cate...

  18. Hip adduction and abduction strength profiles in elite soccer players

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Serner, Andreas; Petersen, Jesper;

    2011-01-01

    An ipsilateral hip adduction/abduction strength ratio of more than 90%, and hip adduction strength equal to that of the contralateral side have been suggested to clinically represent adequate strength recovery of hip adduction strength in athletes after groin injury. However, to what extent side-...

  19. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... for hip replacement we present them with the risks and the benefits of surgery and allow the patients to decide for themselves ... bilateral hip replacement surgery. And bilateral hip replacement surgery has ... condition; good health, no associated medical problems, not too old. So ...

  20. [Juvenile hip dislocation and the Vojta neuro-physiotherapy].

    Science.gov (United States)

    Schütt, B

    1981-09-17

    Partial dislocation of the hip in case of cerebral palsy is a result of the disturbance of the neuromuscular system. Immobilization cannot improve the inadequate function the hip. A case of a girl is reported; stabilization of the hip after 3 years of neurophysio-therapy after Vojta could be achieved. PMID:7274945

  1. Transfusion practice in hip arthroplasty - a nationwide study

    DEFF Research Database (Denmark)

    Jans, Øivind; Kehlet, H; Hussain, Zubair Butt;

    2011-01-01

    Background and Objectives The optimal transfusion strategy in hip arthroplasty remains controversial despite existing guidelines. The aim of this study was to evaluate the transfusion practice in patients undergoing primary total hip arthroplasty (THA) or revision total hip arthroplasty (RTHA) in...

  2. Fixation method does not affect restoration of rotation center in hip replacements: A single-site retrospective study

    Directory of Open Access Journals (Sweden)

    Wegner Alexander

    2012-06-01

    Full Text Available Abstract Background Aseptic loosening is one of the greatest problems in hip replacement surgery. The rotation center of the hip is believed to influence the longevity of fixation. The aim of this study was to compare the influence of cemented and cementless cup fixation techniques on the position of the center of rotation because cemented cup fixation requires the removal of more bone for solid fixation than the cementless technique. Methods We retrospectively compared pre- and post-operative positions of the hip rotation center in 25 and 68 patients who underwent artificial hip replacements in our department in 2007 using cemented or cementless cup fixation, respectively, with digital radiographic image analysis. Results The mean horizontal and vertical distances between the rotation center and the acetabular teardrop were compared in radiographic images taken pre- and post-operatively. The mean horizontal difference was −2.63 mm (range: -11.00 mm to 10.46 mm, standard deviation 4.23 mm for patients who underwent cementless fixation, and −2.84 mm (range: -10.87 to 5.30 mm, standard deviation 4.59 mm for patients who underwent cemented fixation. The mean vertical difference was 0.60 mm (range: -20.15 mm to 10.00 mm, standard deviation 3.93 mm and 0.41 mm (range: -9.26 mm to 6.54 mm, standard deviation 3.58 mm for the cementless and cemented fixation groups, respectively. The two fixation techniques had no significant difference on the position of the hip rotation center in the 93 patients in this study. Conclusions The hip rotation center was similarly restored using either the cemented or cementless fixation techniques in this patient cohort, indicating that the fixation technique itself does not interfere with the position of the center of rotation. To completely answer this question further studies with more patients are needed.

  3. Artificial ionospheric turbulence (review)

    International Nuclear Information System (INIS)

    This study is an analysis of artificial ionospheric turbulence (AIT) arising near the level at which a powerful wave is reflected with ordinary polarization. AIT is an inhomogeneous structure in the ionosphere with a size on the order of centimeters or tens of kilometers and with characteristic frequencies from a fraction of a hertz (aperiodic inhomogeneity) to several megahertz (plasma waves). The authors are primarily concerned with small-scale artificial ionospheric turbulence (SAIT), i.e., with inhomogeneities that are greatly extended along the geomagnetic field with transverse dimensions that are less than the wavelengths of the perturbing waves - the pumping waves (PW) - in a vacuum

  4. 14-3-3/HIP-55 complex increases the stability of HIP-55%14-3-3/HIP-55复合体增强HIP-55蛋白稳定性

    Institute of Scientific and Technical Information of China (English)

    田爱炬; 李子健

    2015-01-01

    目的:用双分子荧光互补及免疫共沉淀技术验证HIP-55与14-3-3在HEK293细胞中存在相互作用,并进一步研究其生物学意义. 方法:利用GATEWAY系统构建PDEST-N-Venus-HIP-55WT(野生型),PDEST-N-Venus-HIP-55AA(突变体S269A/T291A),PDEST-GST-HIP-55WT及PDEST-C-Venus-14-3-3τ重组质粒,利用双分子荧光互补及免疫共沉淀技术检测两者的相互作用,同时应用14-3-3蛋白相互作用抑制肽R18和HIP-55蛋白突变体( HIP-55AA突变体S269A/T291A不能与14-3-3相互作用)作为工具研究两者结合后对嘌呤霉素诱导的HIP-55蛋白表达的影响. 结果:外源转入的Venus-HIP-55WT、Venus-HIP-55AA及Venus-14-3-3蛋白能够在HEK293细胞中表达;双分子荧光互补实验结果表明HIP-55与14-3-3存在相互作用,HIP-55蛋白的S269/T291位点介导HIP-55与14-3-3的相互作用;免疫共沉淀技术表明内源性HIP-55与14-3-3存在相互作用;进一步研究发现HIP-55与14-3-3复合体增强HIP-55蛋白的稳定性,保护HIP-55不被降解. 结论:14-3-3与HIP-55存在相互作用,14-3-3/HIP-55复合体可以促进HIP-55蛋白的稳定性.%Objective:To further demonstrate the interaction of a new 14-3-3 interaction protein hema-topoietic progenitor kinase 1 [ HPK1 ]-interacting protein ( HIP-55 ) and 14-3-3 proteins and its potential biological function in HEK293 cells. Methods:PDEST-N-Venus-HIP-55WT (wild type),PDEST-N-Ve-nus-HIP-55AA (mutants, S269A/T291A, abolishing the binding of HIP-55 to 14-3-3),PDEST-GST-HIP-55WT and PDEST-C-Venus-14-3-3τplasmids were constructed by gateway system. Their expressions were demonstrated by Western blotting method. Then we used Bimolecular Fluorescence Complementation ( BiFC) and co-immunoprecipitation ( co-IP) methods to demonstrate the interaction of HIP-55 and 14-3-3 in HEK293 cells. Moreover, the 14-3-3 antagonist peptide, R18 and HIP-55 protein mutant plasmid HIP-55 AA were used to detect the protein synthesis of HIP-55 at different time points

  5. Featherless Dinosaurs and the Hip-Hop Simulacrum: Reconsidering Hip-Hop's Appropriateness for the Music Classroom

    Science.gov (United States)

    Kruse, Adam J.

    2016-01-01

    This article offers considerations for music teachers interested in including hip-hop music in their classrooms but who might feel concerned with or overwhelmed by issues of appropriateness. Two concerns related to hip-hop music are examined: language and negative social themes. Commercial interests in hip-hop music have created a simulacrum (or…

  6. The Formation of "Hip-Hop Academicus"--How American Scholars Talk about the Academisation of Hip-Hop

    Science.gov (United States)

    Soderman, Johan

    2013-01-01

    Social activism and education have been associated with hip-hop since it emerged in New York City 38 years ago. Therefore, it might not be surprising that universities have become interested in hip-hop. This article aims to highlight this "hip-hop academisation" and analyse the discursive mechanisms that manifest in these academisation…

  7. 全髋关节置换术治疗27例髋关节发育不良合并骨性关节炎%Total Hip Arthroplasty for 27 Cases with Hip Dysplasia and Osteoarthritis

    Institute of Scientific and Technical Information of China (English)

    罗育润

    2014-01-01

    Objective To explore the clinical effect of total hip arthroplasty on 27 cases with hip dysplasia and osteoarthritis. Methods 27 patients (33 hips) with hip dysplasia and osteoarthritis admitted in our hospital including 9 patients with Crowe type IV (12 hips), 12 patients with Crowe type Ⅲ (15 hips), 6 patients with Crowe typeⅡ(6 hips), were given total hip arthroplasty. The surgery time, hip function and corrective recovery were counted and analyzed; all the patients were followed for 3 years. Results All the operations of the patients were conducted successfully. The operation time was 65~120min; the bilateral difference in leg length was 0.5~3cm after the operation; X-ray showed that artificial acetabulums were located in the true hip socket, no prosthesis loosening;the result of the last visit showed that Harris hip score was significantly higher than the preoperative score (preoperative score was 45.15 ± 8.81; the score at 36-month visit was 87.88 ± 6.33); the range of motion was improved to some extent and the patients were satisfied with the treatment effect. Conclusion Total hip arthroplasty is an effective way for treating hip dysplasia complicated by osteoarthritis, which can correct the joint deformities, improve the joint function, and is worthy of popularization and application.%目的:探讨全髋关节置换术对髋关节发育不良合并骨性关节炎的临床疗效。方法对该院27例(33髋)髋关节发育不良合并骨性关节炎的患者施行全髋关节置换术,其中Crowe IV型患者9例(12髋),Crowe Ⅲ型患者12例(15髋),CroweⅡ型患者6例(6髋),对手术时间、髋关节功能、矫正恢复情况进行统计分析,所有患者随访3年。结果患者全部顺利完成手术,手术时间在65~120 min,术后双侧下肢长度差在0.5~3 cm,X片示人工髋臼均位于真髋关节窝内,假体无松动移位,末次回访髋关节Harris评分明显高于术前评分[分别为术前评分(45.15±8.81);36

  8. MANAGEMENT OF INTERTROCHANTER FRACTURES OF HIP WITH DYNAMIC HIP SCREW : A CLINICAL STUDY

    Directory of Open Access Journals (Sweden)

    Nageshwara Rao

    2015-09-01

    Full Text Available BACKGROUND & OBJECTIVES: Fractures of proximal femur are the most commonly encountered fractures by orthopedic surgeon. Many management techniques are described in literature but internal fixation with Dynamic Hip Screw is the treatment of choice. This study analyzes the outcome of treatment of intertrochanteric fra cture with Dynamic Hip Screw. MATERIALS AND METHODS: Between April 2010 and May 2012, 40 patients with intertrochanteric fracture admitted in the department of Orthopedics, Government General Hospital, Kurnool were treated with internal fixation with Dynam ic Hip Screw and the results were evaluated using Kyle’s criteria. RESULTS : Incidence among both sexes was same. Average age of occurrence was 62.7 years, with level of osteoporosis Singh’s index 3 or 4. There were 25% excellent, 50% good, 15% fair, 10% po or results. CONCLUSION : Internal fixation with Dynamic Hip Screw is the treatment of choice for treatment of intertrochanteric fractures.

  9. Production of artificial radioelements

    International Nuclear Information System (INIS)

    The techniques used in the production of artificial radioelements are described, with special emphasis on the following points: - nuclear reactions and use of reactors; - chemical separation methods and methods for enriching the activity of preparations; - protection of personnel and handling methods. (author)

  10. Artificial Left Ventricle

    CERN Document Server

    Ranjbar, Saeed; Meybodi, Mahmood Emami

    2014-01-01

    This Artificial left ventricle is based on a simple conic assumption shape for left ventricle where its motion is made by attached compressed elastic tubes to its walls which are regarded to electrical points at each nodal .This compressed tubes are playing the role of myofibers in the myocardium of the left ventricle. These elastic tubes have helical shapes and are transacting on these helical bands dynamically. At this invention we give an algorithm of this artificial left ventricle construction that of course the effect of the blood flow in LV is observed with making beneficiary used of sensors to obtain this effecting, something like to lifegates problem. The main problem is to evaluate powers that are interacted between elastic body (left ventricle) and fluid (blood). The main goal of this invention is to show that artificial heart is not just a pump, but mechanical modeling of LV wall and its interaction with blood in it (blood movement modeling) can introduce an artificial heart closed to natural heart...

  11. Observations of artificial satellites

    Directory of Open Access Journals (Sweden)

    A. MAMMANO

    1964-06-01

    Full Text Available The following publication gives the results of photographic
    observations of artificial satellites made at Asiago during the second
    and third year of this programme. The fixed camera technique and that
    with moving film (the latter still in its experimental stage have been used.

  12. Artificial intelligence within AFSC

    Science.gov (United States)

    Gersh, Mark A.

    1990-01-01

    Information on artificial intelligence research in the Air Force Systems Command is given in viewgraph form. Specific research that is being conducted at the Rome Air Development Center, the Space Technology Center, the Human Resources Laboratory, the Armstrong Aerospace Medical Research Laboratory, the Armamant Laboratory, and the Wright Research and Development Center is noted.

  13. Terahertz Artificial Dielectric Lens

    Science.gov (United States)

    Mendis, Rajind; Nagai, Masaya; Wang, Yiqiu; Karl, Nicholas; Mittleman, Daniel M.

    2016-03-01

    We have designed, fabricated, and experimentally characterized a lens for the THz regime based on artificial dielectrics. These are man-made media that mimic properties of naturally occurring dielectric media, or even manifest properties that cannot generally occur in nature. For example, the well-known dielectric property, the refractive index, which usually has a value greater than unity, can have a value less than unity in an artificial dielectric. For our lens, the artificial-dielectric medium is made up of a parallel stack of 100 μm thick metal plates that form an array of parallel-plate waveguides. The convergent lens has a plano-concave geometry, in contrast to conventional dielectric lenses. Our results demonstrate that this lens is capable of focusing a 2 cm diameter beam to a spot size of 4 mm, at the design frequency of 0.17 THz. The results further demonstrate that the overall power transmission of the lens can be better than certain conventional dielectric lenses commonly used in the THz regime. Intriguingly, we also observe that under certain conditions, the lens boundary demarcated by the discontinuous plate edges actually resembles a smooth continuous surface. These results highlight the importance of this artificial-dielectric technology for the development of future THz-wave devices.

  14. Artificial Gravity Research Plan

    Science.gov (United States)

    Gilbert, Charlene

    2014-01-01

    This document describes the forward working plan to identify what countermeasure resources are needed for a vehicle with an artificial gravity module (intermittent centrifugation) and what Countermeasure Resources are needed for a rotating transit vehicle (continuous centrifugation) to minimize the effects of microgravity to Mars Exploration crewmembers.

  15. Spatially Resolved Artificial Chemistry

    DEFF Research Database (Denmark)

    Fellermann, Harold

    2009-01-01

    made a class of models accessible to the realms of artificial chemistry that represent reacting molecules in a coarse-grained fashion in continuous space. This chapter introduces the mathematical models of Brownian dynamics (BD) and dissipative particle dynamics (DPD) for molecular motion and reaction...

  16. Natural or Artificial Intelligence?

    Czech Academy of Sciences Publication Activity Database

    Havlík, Vladimír

    Plzeň: University of West Bohemia, 2013 - (Romportl, J.; Ircing, P.; Zackova, E.; Polak, M.; Schuster, R.), s. 15-27 ISBN 978-80-261-0275-5. [International Conference Beyond AI 2013. Plzeň (CZ), 12.11.2013-14.11.2013] Institutional support: RVO:67985955 Keywords : artificial intelligence * natural intelligence * artifact * natural process * intrinsic intentionality Subject RIV: AA - Philosophy ; Religion

  17. Artificial Intelligence and CALL.

    Science.gov (United States)

    Underwood, John H.

    The potential application of artificial intelligence (AI) to computer-assisted language learning (CALL) is explored. Two areas of AI that hold particular interest to those who deal with language meaning--knowledge representation and expert systems, and natural-language processing--are described and examples of each are presented. AI contribution…

  18. Micromachined Artificial Haircell

    Science.gov (United States)

    Liu, Chang (Inventor); Engel, Jonathan (Inventor); Chen, Nannan (Inventor); Chen, Jack (Inventor)

    2010-01-01

    A micromachined artificial sensor comprises a support coupled to and movable with respect to a substrate. A polymer, high-aspect ratio cilia-like structure is disposed on and extends out-of-plane from the support. A strain detector is disposed with respect to the support to detect movement of the support.

  19. Predicting discharge location of hip fracture patients; the new discharge of hip fracture patients score

    OpenAIRE

    Vochteloo, Anne; Tuinebreijer, Wim; Maier, Andrea; Nelissen, Rob; Bloem, Rolf; Pilot, Peter

    2012-01-01

    textabstractPurpose This paper reports on the development and validity of a new instrument, called the discharge of hip fracture patients score (DHP), that predicts at admission the discharge location in patients living in their own home prior to hip fracture surgery. Methods A total of 310 patients aged 50 years and above were included. Risk factors for discharge to an alternative location (DAL) were analysed with a multivariable regression analysis taking the admission variables into accoun...

  20. Total Hip Prosthesis in Coxarthrosis due to Congenital Dislocation or Subluxation of the Hip

    OpenAIRE

    Aritamur, Ayhan; Cakmak, Mehmet; Taser, Omer

    2004-01-01

    At our clinic, total hip prostheses were adapted in 4 cases with coxarthrosis accompanied by severe acetabular insufficiency due to congenital hip dislocation or Subluxation. For the reconstruction of acetabuler insufficiency, femoral head was employed as graft in compliance with the Harris technique. This technique was realized on the patient in between two stages with the purpose of avoding femoral resection, yet temporary neurologic symptoms appeared posfoperatively in this case of ours. O...

  1. Assessment of outcome after hip fracture: development of a universal assessment system for hip fractures

    OpenAIRE

    Bowers Thomas M.; Parker Martyn J.

    2016-01-01

    Background: The aim of the study was to refine current evaluation systems used to assess outcome after a hip fracture and to devise a simple and practical system to assess all hip fracture patients. Methods: Three continuous scales were defined for pain, mobility and functional independence. These were all found to have an acceptable degree of inter-observer agreement. The pre-fracture mobility and independence scores were related to the one-year mortality for a consecutive se...

  2. Heterotopic ossification after hip arthroplasty: a randomized double-blind multicenter study tenoxicam in 147 hips

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Sletgård, J; Dalsgård, J; Soelberg, M; Keisu, K; Hänninen, A; Crawford, M

    1996-01-01

    147 patients due to have a cemented total hip arthroplasty were randomized to 4 groups. They received either tenoxicam 20 mg or 40 mg, or placebo, for 5 days or morphine on the day of operation and placebo for 4 days. During the first 5 days 14 patients were excluded. The patients were followed for...... tenoxicam 20 mg for 5 days postoperatively can reduce heterotopic ossification after cemented total hip arthroplasty....

  3. Total Hip Arthroplasty in Mucopolysaccharidosis Type IH

    OpenAIRE

    S. O'hEireamhoin; Bayer, T.; Mulhall, K. J.

    2012-01-01

    Children affected by mucopolysaccharidosis (MPS) type IH (Hurler Syndrome), an autosomal recessive metabolic disorder, are known to experience a range of musculoskeletal manifestations including spinal abnormalities, hand abnormalities, generalised joint stiffness, genu valgum, and hip dysplasia and avascular necrosis. Enzyme therapy, in the form of bone marrow transplantation, significantly increases life expectancy but does not prevent the development of the associated musculoskeletal disor...

  4. Interactive segmentation of Hip Joint Cartilage

    Czech Academy of Sciences Publication Activity Database

    Dvořák, Pavel; Juráš, V.; Vogl, W.; Chytil, J.

    Cambridge: The Electromagnetics Academy, 2014, s. 2369-2372. ISBN 978-1-934142-28-8. [PIERS 2014. Progress In Electromagnetics Research Symposium /35./. Guangzhou (CN), 25.08.2014-28.08.2014] R&D Projects: GA ČR GAP102/12/1104 Institutional support: RVO:68081731 Keywords : hip joint * MRI * segmentation of cartilage Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  5. Screening for developmental dysplasia of the hip

    NARCIS (Netherlands)

    Boere-Boonekamp, Magda M.; Verkerk, Paul H.

    1998-01-01

    The success rates of screening programmes for Developmental Dysplasia of the Hip (DDH) vary widely. Studies on screening programmes for DDH based on a Medline search for the years 1966–1997 are reviewed. The percentage treated in most studies, especially those using ultrasound, are high and suggest

  6. The Rap on Hip-Hop

    Science.gov (United States)

    Piekarski, Bill

    2004-01-01

    From its humble origins some 30 years ago in New York's bombed-out, poverty-ravaged South Bronx, hip-hop has risen to become a dominant cultural force both here and abroad. Strictly defined, the term refers to the entire cultural constellation that accompanies rap music, which in 2001 surpassed country music as the most popular musical genre in…

  7. A Bilateral Traumatic Hip Obturator Dislocation

    Science.gov (United States)

    Karaarslan, Ahmet Adnan; Acar, Nihat; Karci, Tolga; Sesli, Erhan

    2016-01-01

    A case of a bilateral simultaneous traumatic obturator dislocation of both hip joints in an 18-year-old young man following a traffic accident is presented. We reduced the dislocated femoral heads immediately under general anesthesia followed by passive and active exercises and early full-weight bearing mobilization. After 5 years, the result was excellent. PMID:26977327

  8. Management of hip posture in cerebral palsy.

    OpenAIRE

    Clarke, A M; Redden, J. F.

    1992-01-01

    Seating arrangements for cerebral palsy children with total body involvement are often unsatisfactory and can pose considerable problems for the multi-disciplinary team. Hip joints at risk of dislocation must be kept in an abducted position in order to minimize pain. A new wheelchair with a barrel-shaped cylindrical seat has been developed which improves the femoral head location and alleviates pain.

  9. Hip and knee arthroplasty: quo vadis?

    NARCIS (Netherlands)

    Ho, J.; Meis, J.F.G.M.; Nabuurs-Franssen, M.H.; Voss, A.

    2015-01-01

    Despite of the steady decrease of surgical site infection (SSI) over the last two decades, the incidence of SSI after hip and knee arthroplasty has recently surged. This may be explained by technical changes that may result in an increased risk of SSI, such as the broad implementation of fast track

  10. Contralateral Total Hip Arthroplasty After Hindquarter Amputation

    Directory of Open Access Journals (Sweden)

    Scott M. M. Sommerville

    2006-01-01

    Full Text Available We describe the management and outcome of a 62-year old lady who developed severe osteoarthritis of the hip, nine years after a hindquarter amputation for radiation-induced sarcoma of the contralateral pelvis. The difficulties of stabilising the pelvis intraoperatively and the problems of postoperative rehabilitation are outlined. The operation successfully relieved her pain and restored limited mobility.

  11. Uudised : Ooper. Hip-hop. Madonna

    Index Scriptorium Estoniae

    2005-01-01

    Rumeenia sopran Nelly Miricioiu Vincenzo Bellini ooperi "Norma" nimiosas Nederlandse Operas Amsaterdamis 7.-28. märtsini. 4. märtsil Tallinna klubis Hollywood üritusel "Hip-Hop Café" New Yorgi duo Camp Lo. Ameerika poplaulja Madonna võttis vastu filmirolli

  12. The Philippine "Hip Hop Stick Dance"

    Science.gov (United States)

    Lewis, Lisa

    2012-01-01

    This article introduces a dance that blends the traditional cultural heritage of the Philippines with modern music and moves. "Hip Hop Stick Dance" incorporates Tinikling (the Philippine national dance) and Arnis (a Filipino style of martial arts) to create a contemporary combination of rhythm, dance, and fitness. It was designed to introduce…

  13. Influence of Hip Pop on American Teens

    Institute of Scientific and Technical Information of China (English)

    王昕苹

    2006-01-01

    Hip pop has become the mainstream music in American right now, not only because of its multi-musical style but also because of the lyrics has a historic background. Its popularity has great impact on American teens ,especially on the fashion and the lifestyle.

  14. Mortality analysis in hip fracture patients

    DEFF Research Database (Denmark)

    Foss, N B; Kehlet, H

    2005-01-01

    Patients with hip fractures are usually frail and elderly with a 30-day mortality in excess of 10% in European series. Perioperative morbidity is often multifactorial in nature, and unimodal interventions will not necessarily decrease mortality. The purpose of this prospective study was to analys...

  15. Preventable mortality in geriatric hip fracture inpatients

    Science.gov (United States)

    Tarrant, S. M.; Hardy, B. M.; Byth, P. L.; Brown, T. L.; Attia, J.; Balogh, Z. J.

    2014-01-01

    There is a high rate of mortality in elderly patients who sustain a fracture of the hip. We aimed to determine the rate of preventable mortality and errors during the management of these patients. A 12 month prospective study was performed on patients aged > 65 years who had sustained a fracture of the hip. This was conducted at a Level 1 Trauma Centre with no orthogeriatric service. A multidisciplinary review of the medical records by four specialists was performed to analyse errors of management and elements of preventable mortality. During 2011, there were 437 patients aged > 65 years admitted with a fracture of the hip (85 years (66 to 99)) and 20 died while in hospital (86.3 years (67 to 96)). A total of 152 errors were identified in the 80 individual reviews of the 20 deaths. A total of 99 errors (65%) were thought to have at least a moderate effect on death; 45 reviews considering death (57%) were thought to have potentially been preventable. Agreement between the panel of reviewers on the preventability of death was fair. A larger-scale assessment of preventable mortality in elderly patients who sustain a fracture of the hip is required. Multidisciplinary review panels could be considered as part of the quality assurance process in the management of these patients. Cite this article: Bone Joint J 2014;96-B:1178–84. PMID:25183587

  16. A Water Rehabilitation Program in Patients with Hip Osteoarthritis Before and After Total Hip Replacement.

    Science.gov (United States)

    Łyp, Marek; Kaczor, Ryszard; Cabak, Anna; Tederko, Piotr; Włostowska, Ewa; Stanisławska, Iwona; Szypuła, Jan; Tomaszewski, Wiesław

    2016-01-01

    BACKGROUND Pain associated with coxarthrosis, typically occurring in middle-aged and elderly patients, very commonly causes considerable limitation of motor fitness and dependence on pharmacotherapy. This article provides an assessment of a rehabilitation program with tailored water exercises in patients with osteoarthritis before and after total hip replacement. MATERIAL AND METHODS A total of 192 patients (the mean age 61.03±10.89) suffering from hip osteoarthritis (OA) were evaluated before and after total hip replacement (THR). The clinical study covered measurements of hip active ranges of motion (HAROM) and the forces generated by pelvis stabilizer muscles. Pain intensity was assessed according to analogue-visual scale of pain (VAS) and according to the Modified Laitinen Questionnaire. The patients were divided into 6 groups (4 treatment and 2 control). We compared 2 rehabilitation programs using kinesitherapy and low-frequency magnetic field. One of them also had specially designed exercises in the water. Statistical analysis was carried out at the significance level α=0.05. This was a cross-sectional study. RESULTS A positive effect of water exercises on a number of parameters was found in patients with OA both before and after total hip replacement surgery. We noted a significant reduction of pain (pwater exercises most significantly reduced pain in patients with OA before and after total hip replacement surgery. 2. Inclusion of water exercises in a rehabilitation program can reduce the use of medicines in patient with OA and after THR. PMID:27455419

  17. Introduction to Artificial Neural Networks

    DEFF Research Database (Denmark)

    Larsen, Jan

    1999-01-01

    The note addresses introduction to signal analysis and classification based on artificial feed-forward neural networks.......The note addresses introduction to signal analysis and classification based on artificial feed-forward neural networks....

  18. Inflatable artificial sphincter - series (image)

    Science.gov (United States)

    An artificial urinary sphincter is used to treat stress incontinence in men that is caused by urethral dysfunction such ... An artificial sphincter consists of three parts: a cuff that fits around the bladder neck a pressure regulating balloon ...

  19. Large strengthening effect of a hip-flexor training programme

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Bandholm, Thomas Quaade; Zebis, Mette; Andersen, Lars Louis; Jensen, Jesper; Hölmich, Per

    2015-01-01

    PURPOSE: To investigate the effect on hip-flexion strength of a 6-week hip-flexor training programme using elastic bands as resistance. We hypothesized that the training group, compared to a control group, would increase their hip-flexion strength more. METHODS: Thirty-three healthy subjects (45...... % females), 24(5) years of age, were included in a randomized controlled trial and allocated to heavy strength training of the hip-flexor muscles or to control (no strength training). Strength training of the hip-flexors (dominant leg) was performed three times 10 min per week for 6 weeks. The strength...... training group progressed from 15 repetition maximum (RM) (week 1) to 8 RM (week 6). Isometric hip-flexion strength (primary outcome) was measured by a blinded assessor using a reliable test procedure. RESULTS: In the strength training group, the isometric hip-flexion strength of the trained leg increased...

  20. Multimodal Analgesia in the Hip Fracture Patient.

    Science.gov (United States)

    Fabi, David W

    2016-05-01

    Hip fracture is one of the most common injuries among the elderly and, because the population is aging, it is expected to remain a major clinical challenge and public health problem for the foreseeable future. The clinical importance of early mobilization and prompt participation in physical therapy after hip fracture surgery is now widely recognized. Because postoperative pain can impair mobility and delay physical therapy, much attention is now being paid to finding more effective ways of controlling pain after hip fracture. Oversedation with opioid drugs inhibits communication between the patient and the health care team, can delay ambulation and rehabilitation therapy, and may increase the probability of the patient requiring a skilled nursing facility, which adds further cost to the overall health care system. Multiple pain pathways contribute to the perception of postoperative pain, and although opioids are highly effective in blocking nociceptive pain through inhibition of the mu receptors, they do not block other pain pathways. Multimodal analgesia involves the use of several anesthetic and analgesic modalities that are strategically combined to block pain perception at different sites in the peripheral and central nervous systems. This balanced, multifaceted approach provides more effective control of postoperative pain than opioid drugs alone, allows lower doses of opioids to be used as part of the multimodal regimen (thereby reducing the risk of opioid-related adverse events and complications), and may facilitate more rapid recovery and improve certain outcome measures related to recovery time. One prospective randomized study evaluating the clinical value of multimodal pain management in elderly patients undergoing bipolar hip hemiarthroplasty found that a multimodal regimen, including preemptive pain medication and intraoperative periarticular injections, reduced pain on postoperative days 1 and 4, and reduced overall opioid use. This article describes

  1. Center of Mass Compensation during Gait in Hip Arthroplasty Patients: Comparison between Large Diameter Head Total Hip Arthroplasty and Hip Resurfacing

    OpenAIRE

    Vicky Bouffard; Julie Nantel; Marc Therrien; Pascal-André Vendittoli; Martin Lavigne; François Prince

    2011-01-01

    Objective. To compare center of mass (COM) compensation in the frontal and sagittal plane during gait in patients with large diameter head total hip arthroplasty (LDH-THA) and hip resurfacing (HR). Design. Observational study. Setting. Outpatient biomechanical laboratory. Participants. Two groups of 12 patients with LDH-THA and HR recruited from a larger randomized study and 11 healthy controls. Interventions. Not applicable. Main Outcome Measures. To compare the distance between the hip pros...

  2. Greater Hip Extension but Not Hip Abduction Explosive Strength Is Associated With Lesser Hip Adduction and Knee Valgus Motion During a Single-Leg Jump-Cut

    OpenAIRE

    Cronin, Baker; Johnson, Samuel T; Chang, Eunwook; Pollard, Christine D.; Norcross, Marc F.

    2016-01-01

    Background: The relationships between hip abductor and extensor strength and frontal plane hip and knee motions that are associated with anterior cruciate ligament injury risk are equivocal. However, previous research on these relationships has evaluated relatively low-level movement tasks and peak torque rather than a time-critical strength measure such as the rate of torque development (RTD). Hypothesis: Females with greater hip abduction and extension RTD would exhibit lesser frontal plane...

  3. Artificial Intelligence and Information Retrieval.

    Science.gov (United States)

    Teodorescu, Ioana

    1987-01-01

    Compares artificial intelligence and information retrieval paradigms for natural language understanding, reviews progress to date, and outlines the applicability of artificial intelligence to question answering systems. A list of principal artificial intelligence software for database front end systems is appended. (CLB)

  4. Hip hop jako kulturní styl, jeho spicifika a vliv na teenagery

    OpenAIRE

    Pospíšil, Jan

    2008-01-01

    This thesis involves history of hip hop, its specifics and elements, it talks about influence of hip hip subculture on teenagers and points to positive and negative aspects connected to this culture style. In this way is work sectionalized into chapters. First part talks about history of hip hop, connection between religion and hip hop and also about Czech hip hop. Second part specifies on main elements of hip hop culture as DJing, MCing, breakdance, beatbox and graffiti. Last part focuses on...

  5. Theoretical and practical aspects in total uncemented hip arthroplasty by using short femoral stem prosthesis

    OpenAIRE

    Moga, M; Pogarasteanu, ME; Barbilian, A

    2015-01-01

    Hip arthrosis, primary or secondary, is an osteoarthritic degenerative process that affects the hip joint. Primary hip arthrosis has an unknown etiology, and secondary hip arthrosis has well defined causes; of these causes, some are known to lead to arthrosis of the hip in the young age patient. The surgical treatment aims either to preserve the patient’s hip joint, or to replace the joint. The most commonly used procedure at this time is the total hip arthroplasty. The femoral component may ...

  6. Greater Hip Extension but Not Hip Abduction Explosive Strength Is Associated With Lesser Hip Adduction and Knee Valgus Motion During a Single-Leg Jump-Cut

    Science.gov (United States)

    Cronin, Baker; Johnson, Samuel T.; Chang, Eunwook; Pollard, Christine D.; Norcross, Marc F.

    2016-01-01

    Background: The relationships between hip abductor and extensor strength and frontal plane hip and knee motions that are associated with anterior cruciate ligament injury risk are equivocal. However, previous research on these relationships has evaluated relatively low-level movement tasks and peak torque rather than a time-critical strength measure such as the rate of torque development (RTD). Hypothesis: Females with greater hip abduction and extension RTD would exhibit lesser frontal plane hip and knee motion during a single-leg jump-cutting task. Study Design: Descriptive laboratory study. Methods: Forty recreationally active females performed maximal isometric contractions and single-leg jump-cuts. From recorded torque data, hip extension and abduction RTD was calculated from torque onset to 200 ms after onset. Three-dimensional motion analysis was used to quantify frontal plane hip and knee kinematics during the movement task. For each RTD measure, jump-cut biomechanics were compared between participants in the highest (high) and lowest (low) RTD tertiles. Results: No differences in frontal plane hip and knee kinematics were identified between high and low hip abduction RTD groups. However, those in the high hip extension RTD group exhibited lower hip adduction (high, 3.8° ± 3.0°; low, 6.5° ± 3.0°; P = .019) and knee valgus (high, –2.5° ± 2.3°; low, –4.4° ± 3.2°; P = .046) displacements during the jump-cut. Conclusion: In movements such as cutting that are performed with the hip in a relatively abducted and flexed position, the ability of the gluteus medius to control hip adduction may be compromised. However, the gluteus maximus, functioning as a hip abductor, may take on a pivotal role in controlling hip adduction and knee valgus motion during these types of tasks. Clinical Relevance: Training with a specific emphasis on increasing explosive strength of the hip extensors may be a means through which to improve frontal plane hip and knee

  7. HIP10680/HIP10679: a visual binary in the $\\beta$ Pictoris Association with the fastest rotating member

    CERN Document Server

    Messina, Sergio; Zambelli, Roberto

    2015-01-01

    We present the results of a multi-filter photometric monitoring of the wide binary HIP10680/HIP10679. We found both component to be variable with amplitude up to $\\Delta$V = 0.03 mag in the case of HIP10680 and $\\Delta$V = 0.07 mag in the case of HIP10679. We could measure the rotation periods P = 0.2396d of the hotter F5V component HIP10680 and P = 0.777d of the cooler G5V component HIP10679. We found that the rotation axes of both components are aligned with an inclination $i$ = $\\sim$ 10$^{\\circ}$. Although the two components have a mass difference not larger than 15%, they exhibit a significant difference between their rotation periods. Such difference may arise either from different initial rotation periods or to different disc life times. For instance, the slower rotating component HIP 10679 hosts a well know debris disc.

  8. Neutron activation studies of the in-body corrosion of hip-joint prostheses made of Co-Cr alloys

    International Nuclear Information System (INIS)

    Using instrumental neutron activation analysis (INAA) the trace element composition of 18 elements was investigated in human tissues (articular capsule and fascia lata) of 36 persons after removal of hip-joint prostheses made of Co-Cr alloys. Normal trace element concentrations were determined studying a group of 26 patients before receiving their first artificial hip-joint. The tissues of patients with metal implants exhibited a heavy burdening by corrosion products (Co, Cr, Ni) from the prostheses as well as by Zr, Hf and Ba from the bone cements. Moreover, changes in the distribution of trace elements not contained in the steel were also observed. A comparison of the analytical results with those of model experiments of the corrosion of Co-Cr alloy in Ringer's solution demonstrates that the distribution pattern of corrosion products in the tissues are influenced by both, the biochemical properties as well as by selective dissolution of the alloy constituents. (author)

  9. Artificial Enzymes, "Chemzymes"

    DEFF Research Database (Denmark)

    Bjerre, Jeannette; Rousseau, Cyril Andre Raphaël; Pedersen, Lavinia Georgeta M;

    2008-01-01

    Enzymes have fascinated scientists since their discovery and, over some decades, one aim in organic chemistry has been the creation of molecules that mimic the active sites of enzymes and promote catalysis. Nevertheless, even today, there are relatively few examples of enzyme models that...... successfully perform Michaelis-Menten catalysis under enzymatic conditions (i.e., aqueous medium, neutral pH, ambient temperature) and for those that do, very high rate accelerations are seldomly seen. This review will provide a brief summary of the recent developments in artificial enzymes, so called...... "Chemzymes", based on cyclodextrins and other molecules. Only the chemzymes that have shown enzyme-like activity that has been quantified by different methods will be mentioned. This review will summarize the work done in the field of artificial glycosidases, oxidases, epoxidases, and esterases, as well as...

  10. The Hip Lag Sign--prospective blinded trial of a new clinical sign to predict hip abductor damage.

    Directory of Open Access Journals (Sweden)

    Alexander Kaltenborn

    Full Text Available This study introduces and validates the Hip Lag Sign, a new clinical parameter to determine hip abductor damage, which appears to be one major cause for greater trochanteric pain syndrome. 26 patients who underwent standardized MRI-examination were prospectively enrolledbetween October 2009 and March 2012. A standard physical examination of the hip was performed, including the Hip Lag Sign as it is defined for the first time in this work. Hip Lag Sign results were statistically compared toMR images, to pain levels measured with the visual analogue scale and to results of the modified Harris Hip Score as a universal and well established diagnostic tool for the hip. Chi2- and Mann-Whitney-U-analysis were applied. Diagnostic accuracy was tested with 2×2-table-calculations.Kappa statistics were used to analyze inter-observer variability. A positive Hip Lag Sign is significantly associated with MRI-proven hip abductor damage (p<0.001. The Hip Lag Sign has a sensitivity of 89.47% and a specificity of 96.55%. The positive and negative predictive values are 94.44%, resp. 93.33%. Its diagnostic Odds Ratio is 239.000 (p<0.001; 95%-CI: 20.031-2827.819. The number needed to diagnose was 1.16.Inter-observer consistency was 98.1% and kappa statistics for inter-observer variability were 0.911. The Hip Lag Sign is specific and sensitive, easy and fast to perform and allows a reliable assessment on the hip abductors' status, especially when there is no access to further diagnostic devices such as MRI for example due to restricted resources like in developing countries. Thus, we recommend the inclusion of the Hip Lag Sign into everyday hip examinations, especially dealing with patients suffering from greater trochanteric pain syndrome.

  11. Synovial plicae of the hip: evaluation using MR arthrography in patients with hip pain

    Energy Technology Data Exchange (ETDEWEB)

    Bencardino, Jenny T.; La Rocca Vieira, Renata [NYU Hospital for Joint Diseases, Department of Radiology, New York, NY (United States); Kassarjian, Ara [Corades, S.L., Majadahonda-Madrid (Spain); Schwartz, Richard [Longwood MRI Specialists, Brookline, MA (United States); Mellado, Jose M. [Hospital Reina Sofia, Department of Radiology, Tudela (Spain); Kocher, Mininder [Children' s Hospital of Boston, Department of Orthopedic Surgery, Boston, MA (United States)

    2011-04-15

    The appearance and distribution of the intra-articular plicae of the hip have been addressed in few reports in the anatomic and radiological literature. This study aims to determine the prevalence of visible synovial hip plicae using MR arthrography and to measure the association of visible synovial hip plicae with MR arthrographic diagnosis of labral tears, femoroacetabular impingement, and osteoarthritis. Following institutional review board approval, 63 direct MR arthrographic examinations of the hip in 61 patients with a clinical history of hip pain were retrospectively reviewed by two experienced musculoskeletal radiologists in consensus. The following variables were measured using a binary system (0 = absent; 1 = present): labral plica, neck plica, ligamental plica, labral tear, femoroacetabular impingement, and osteoarthritis. The surgical reports and arthroscopic images of 10 patients were reviewed. Statistical analysis was performed using the Fisher's exact test. In all 63 cases at least one plica was visualized on MR-arthrographic images. Labral, neck, and ligamental plicae were found with a prevalence of 76, 97, and 78%, respectively. There was no statistically significant association between the presence of labral tears, femoroacetabular impingement, and osteoarthritis among patients with visible labral, neck, and ligamental plicae. The prevalence of labral tears, femoroacetabular impingement, and osteoarthritis in our patient population was 79, 28, and 28%, respectively. The presence of intra-articular plicae was the only MR-arthrographic finding in 5 of our 63 symptomatic cases. Visible labral, neck, and/or ligamental plicae are highly prevalent on MR-arthrographic images of the hip performed in the setting of hip pain. There was no statistically significant association between the presence of labral tears, femoroacetabular impingement, and osteoarthritis and visible labral, neck, and ligamental plicae. (orig.)

  12. Synovial plicae of the hip: evaluation using MR arthrography in patients with hip pain

    International Nuclear Information System (INIS)

    The appearance and distribution of the intra-articular plicae of the hip have been addressed in few reports in the anatomic and radiological literature. This study aims to determine the prevalence of visible synovial hip plicae using MR arthrography and to measure the association of visible synovial hip plicae with MR arthrographic diagnosis of labral tears, femoroacetabular impingement, and osteoarthritis. Following institutional review board approval, 63 direct MR arthrographic examinations of the hip in 61 patients with a clinical history of hip pain were retrospectively reviewed by two experienced musculoskeletal radiologists in consensus. The following variables were measured using a binary system (0 = absent; 1 = present): labral plica, neck plica, ligamental plica, labral tear, femoroacetabular impingement, and osteoarthritis. The surgical reports and arthroscopic images of 10 patients were reviewed. Statistical analysis was performed using the Fisher's exact test. In all 63 cases at least one plica was visualized on MR-arthrographic images. Labral, neck, and ligamental plicae were found with a prevalence of 76, 97, and 78%, respectively. There was no statistically significant association between the presence of labral tears, femoroacetabular impingement, and osteoarthritis among patients with visible labral, neck, and ligamental plicae. The prevalence of labral tears, femoroacetabular impingement, and osteoarthritis in our patient population was 79, 28, and 28%, respectively. The presence of intra-articular plicae was the only MR-arthrographic finding in 5 of our 63 symptomatic cases. Visible labral, neck, and/or ligamental plicae are highly prevalent on MR-arthrographic images of the hip performed in the setting of hip pain. There was no statistically significant association between the presence of labral tears, femoroacetabular impingement, and osteoarthritis and visible labral, neck, and ligamental plicae. (orig.)

  13. Artificial organisms that sleep.

    OpenAIRE

    Mirolli, Marco; Parisi, Domenico

    2003-01-01

    Abstract Populations of artificial organisms live in an environment in which light is cyclically present (day) or absent (night). Since being active during night is non-adaptive (activity consumes energy which is not compensated by the food found at night) the organisms evolve a sleep/wake behavioral pattern of being active during daytime and sleeping during nighttime. When the population moves to a different environment that contains "caves", they have to get out of a cave although the dark ...

  14. Impacts of Artificial Intelligence

    OpenAIRE

    Trappl, R.

    1986-01-01

    This book, which is intended to serve as the first stage in an iterative process of detecting, predicting, and assessing the impacts of Artificial Intelligence opens with a short "one-hour course" in AI, which is intended to provide a nontechnical informative introduction to the material which follows. Next comes an overview chapter which is based on an extensive literature search, the position papers, and discussions. The next section of the book contains position papers whose richness...

  15. Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Kapil Nahar

    2012-12-01

    Full Text Available An artificial neural network is an information-processing paradigm that is inspired by the way biological nervous systems, such as the brain, process information. The key element of this paradigm is the novel structure of the information processing system. It is composed of a large number of highly interconnected processing elements (neurons working in unison to solve specific problems. Ann’s, like people, learn by example.

  16. Artificial Intelligence in Transition

    OpenAIRE

    Hart, Peter E.

    1984-01-01

    In the past fifteen years artificial intelligence has changed from being the preoccupation of a handful of scientists to a thriving enterprise that has captured the imagination of world leaders and ordinary citizens alike. While corporate and government officials organize new projects whose potential impact is widespread, to date few people have been more affected by the transition than those already in the field. I review here some aspects of this transition, and pose some issues that it rai...

  17. Artificial neural network modelling

    CERN Document Server

    Samarasinghe, Sandhya

    2016-01-01

    This book covers theoretical aspects as well as recent innovative applications of Artificial Neural networks (ANNs) in natural, environmental, biological, social, industrial and automated systems. It presents recent results of ANNs in modelling small, large and complex systems under three categories, namely, 1) Networks, Structure Optimisation, Robustness and Stochasticity 2) Advances in Modelling Biological and Environmental Systems and 3) Advances in Modelling Social and Economic Systems. The book aims at serving undergraduates, postgraduates and researchers in ANN computational modelling. .

  18. Intelligence, Artificial and Otherwise

    OpenAIRE

    Chace, William M.

    1984-01-01

    I rise now to speak with the assumption that all of you know very well what I am going to say. I am the humanist here, the professor of English. We humanists, when asked to speak on questions of science and technology, are notorious for offering an embarrassed and ignorant respect toward those matters, a respect, however, which can all too quickly degenerate into insolent condescension. Face to face with the reality of computer technology, say, or with "artificial intelligence," we humanists ...

  19. Artificial sweetener; Jinko kanmiryo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    The patents related to the artificial sweetener that it is introduced to the public in 3 years from 1996 until 1998 are 115 cases. The sugar quality which makes an oligosaccharide and sugar alcohol the subject is greatly over 28 cases of the non-sugar quality in the one by the kind as a general tendency of these patents at 73 cases in such cases as the Aspartame. The method of manufacture patent, which included new material around other peptides, the oligosaccharide and sugar alcohol isn`t inferior to 56 cases of the formation thing patent at 43 cases, and pays attention to the thing, which is many by the method of manufacture, formation. There is most improvement of the quality of sweetness with 31 cases in badness of the aftertaste which is characteristic of the artificial sweetener and so on, and much stability including the improvement in the flavor of food by the artificial sweetener, a long time and dissolution, fluid nature and productivity and improvement of the economy such as a cost are seen with effect on a purpose. (NEDO)

  20. CT findings of traumatic posterior hip dislocation after reduction

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sung Kyoung; Park, Ji Seon; Ryu, Kyung Nam; Jin, Wook [Kyung Hee University Medical Center, Seoul (Korea, Republic of); Jin Wook

    2008-06-15

    To evaluate the CT images of reduced hips after posterior hip dislocation and to propose specific diagnostic criteria based on the CT results. We retrospectively reviewed the CT findings on 18 reduced hips from 17 patients with radiographs and clinical histories of traumatic posterior hip dislocations by evaluating 18 corresponding CT scans for joint space asymmetry, intra-articular abnormalities (intra-articular fat obliteration, loose bodies, and joint effusion), changes in posterior soft tissue (capsule, muscles, and adjacent fat), the presence, and location of fractures (acetabulum and femoral head). All 18 hips (100%) showed posterior soft tissue changes. In total, 17 hips (94.4%) had intra-articular abnormalities and 15 hips (83.3%) had joint space asymmetries. In addition, 17 hips (94.4%) had fractures involving the acetabula (15 cases, 88.2%) the femoral head (13 cases, 76.5%), or on both sides (11 cases, 64.7%). The most frequent fracture location was in he posterior wall (13/15, 86.7%) of the acetabulum and in the anterior aspect (10/13, 76.9%) of the femoral head. Patients with a prior history of posterior hip dislocation showed specific CT findings after reduction, suggesting the possibility of previous posterior hip dislocations in patients.

  1. Differential diagnosis of pain around the hip joint.

    Science.gov (United States)

    Tibor, Lisa M; Sekiya, Jon K

    2008-12-01

    The differential diagnosis of hip pain is broad and includes intra-articular pathology, extra-articular pathology, and mimickers, including the joints of the pelvic ring. With the current advancements in hip arthroscopy, more patients are being evaluated for hip pain. In recent years, our understanding of the functional anatomy around the hip has improved. In addition, because of advancements in magnetic resonance imaging, the diagnosis of soft tissue causes of hip pain has improved. All of these advances have broadened the differential diagnosis of pain around the hip joint and improved the treatment of these problems. In this review, we discuss the causes of intra-articular hip pain that can be addressed arthroscopically: labral tears, loose bodies, femoroacetabular impingement, capsular laxity, tears of the ligamentum teres, and chondral damage. Extra-articular diagnoses that can be managed arthroscopically are also discussed, including: iliopsoas tendonitis, "internal" snapping hip, "external" snapping hip, iliotibial band and greater trochanteric bursitis, and gluteal tendon injury. Finally, we discuss extra-articular causes of hip pain that are often managed nonoperatively or in an open fashion: femoral neck stress fracture, adductor strain, piriformis syndrome, sacroiliac joint pain, athletic pubalgia, "sports hernia," "Gilmore's groin," and osteitis pubis. PMID:19038713

  2. Hip and pelvis diseases on lumbar AP radiographs including both hip joints

    International Nuclear Information System (INIS)

    To determine the frequency of diseases of the hip and pelvis, as seen of plain radiography of the lumbar spine in patients with suspicious lumbar disease, and to evaluate the methods used of lumbar spine radiography in Korea. Sixty university and training hospitals were randomly selected and asked to describe the projections, film size and radiographic techniques employed for routine radiography in patients with suspected disease of the lumbar spine. Plain radiographs of 1252 patients, taken using 14' x 17' film and depicting both hip joints and the lumbar region, were analysed between March 1999 and February 2000. In 15 patients (1.2%), the radiographs revealed hip or pelvic lesions, confirmed as follows: avascular necrosis of the femoral head (n=11, with bilateral lesions in four cases); sustained ankylosing spondylitis (n=2); acetabular dysplasia (n=1); and insufficiency fracture of the pubic rami secondary to osteoporosis (n=1). In 11 of the 20 hospitals which responded, 14' x 17' film was being used for lumbar radiography, while in the other nine, film size was smaller. Plain radiography of the lumbar spine including both hip joints, may be a useful was to simultaneously evaluate lesions not only of the lumbar spine but also of the hip and/or pelvis

  3. Influence of bone mineral density and hip geometry on the different types of hip fracture

    Directory of Open Access Journals (Sweden)

    Yizhong Li

    2016-01-01

    Full Text Available The aim of this study was to assess the influence of bone mineral density and hip geometry on the fragility fracture of femoral neck and trochanteric region. There were 95 menopausal females of age ≥ 50 years with fragility fracture of hip, including 55 cases of femoral neck fracture and 40 cases of trochanteric fracture. Another 63 non-fractured females with normal bone mineral density (BMD were chosen as control. BMD, hip axis length, neck-shaft angle and structural parameters including cross surface area, cortical thickness and buckling ratio were detected and compared. Compared with control group, the patients with femoral neck fracture or trochanteric fractures had significantly lower BMD of femoral neck, as well as lower cross surface area and cortical thickness and higher buckling ratio in femoral neck and trochanteric region. There were no significant differences of BMD and structural parameters in the femoral neck fracture group and intertrochanteric fracture group. Hip axis length and neck-shaft angle were not significantly different among three groups. The significant changes of BMD and proximal femur geometry were present in the fragility fracture of femoral neck and trochanteric region. The different types of hip fractures cannot be explained by these changes.

  4. Cartilage restoration technique of the hip.

    Science.gov (United States)

    Mardones, Rodrigo; Larrain, Catalina

    2016-04-01

    Hip cartilage lesions represent a diagnostic challenge and can be an elusive source of pain. Treatment may present difficulties due to localization and spherical form of the joint and is most commonly limited to excision, debridement, thermal chondroplasty and microfractures. This chapter will focus in new technologies to enhance the standard techniques. These new technologies are based in stem cells therapies; as intra-articular injections of expanded mesenchymal stem cells, mononuclear concentrate in a platelet-rich plasma matrix and expanded mesenchymal stem cells seeded in a collagen membrane. This review will discuss the bases, techniques and preliminary results obtained with the use of stem cells for the treatment of hip cartilage lesions. PMID:27026816

  5. An unusual pain in the hip

    Science.gov (United States)

    Bangera, Sachin; Dunkow, Paul; Weerasinghe, Suboda; Murugesan, Senthil V.

    2016-01-01

    A 68-year-old previously healthy man presented with increasing right hip pain of 6 months duration. On examination he was found to have a hard mass in the right hip arising from the pelvic bone. Imaging studies were in keeping with a sarcoma arising from the right iliac bone. However, biopsy of this bony lesion confirmed this to be a metastatic adenocarcinoma rather than a primary bone malignancy. Further imaging and a subsequent colonoscopy revealed the primary to be a colonic adenocarcinoma. The unique and unusual nature of this case was the presentation as a solitary bony metastasis from a colonic primary. There is no previously documented report in the literature of such a rare presentation of a colonic adenocarcinoma as a solitary bony lesion mimicking a primary sarcoma in the absence of other signs or symptoms.

  6. Biomimetic Composite-Metal Hip Resurfacing Implant

    Directory of Open Access Journals (Sweden)

    Habiba Bougherara

    2008-01-01

    Full Text Available Hip resurfacing technique is a conservative arthroplasty used in the young patient in which the femoral head is reshaped to accept metal cap with small guide stem. In the present investigation, a hybrid composite-metal resurfacing implant is proposed. The cup is made of carbon fiber/polyamide 12 (CF/PA12 covered with a thin layer of cobalt chrome (Co-Cr. Finite element (FE method was applied to analyze and compare the biomechanical performances of the hybrid hip resurfacing (HHR and the conventional Birmingham (BHR. Results of the finite element analysis showed that the composite implant leads to an increase in stresses in the cancellous bone by more than 15% than BHR, indicating a lower potential for stress shielding and bone fracture and higher potential for bone apposition with the HHR.

  7. Fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik

    2012-01-01

    Fast-track hip and knee arthroplasty aims at giving the patients the best available treatment at all times, being a dynamic entity. Fast-track combines evidence-based, clinical features with organizational optimization including a revision of traditions resulting in a streamlined pathway from...... clinical and organizational aspects of fast-track hip and knee arthroplasty (I–IX). A detailed description of the fast-track set-up and its components is provided. Major results include identification of patient characteristics to predict length of stay and satisfaction with different aspects of the...... hospital stay (I); how to optimize analgesia by using a compression bandage in total knee arthroplasty (II); the clinical and organizational set-up facilitating or acting as barriers for early discharge (III); safety aspects following fast-track in the form of few readmissions in general (IV) and few...

  8. A comparison of leg length and femoral offset discrepancies in hip resurfacing, large head metal-on- metal and conventional total hip replacement: a case series

    Directory of Open Access Journals (Sweden)

    Herman Katie A

    2011-12-01

    Full Text Available Abstract Background A discrepancy in leg length and femoral offset restoration is the leading cause of patient dissatisfaction in hip replacement surgery and has profound implications on patient quality of life. The aim of this study is to compare biomechanical hip reconstruction in hip resurfacing, large-diameter femoral head hip arthroplasty and conventional total hip replacement. Method Sixty patient's post-operative radiographs were reviewed; 20 patients had a hip resurfacing (HR, 20 patients had a Large Head Metal-on-metal (LHM hip replacement and 20 patients had a conventional small head Total Hip Replacement (THR. The leg length and femoral offset of the operated and unoperated hips were measured and compared. Results Hip resurfacing accurately restored hip biomechanics with no statistical difference in leg length (P = 0.07 or femoral offset (P = 0.95 between the operated and non-operative hips. Overall HR was superior for reducing femoral offset discrepancies where it had the smallest bilateral difference (-0.2%, P = 0.9. The traditional total hip replacement was least effective at restoring the hip anatomy. Conclusion The use of a larger-diameter femoral head in hip resurfacing does not fully account for the superior biomechanical restoration, as LHM did not restore femoral offset as accurately. We conclude that restoration of normal hip biomechanics is best achieved with hip resurfacing.

  9. Cartilage restoration technique of the hip

    OpenAIRE

    Mardones, Rodrigo; Larrain, Catalina

    2015-01-01

    Hip cartilage lesions represent a diagnostic challenge and can be an elusive source of pain. Treatment may present difficulties due to localization and spherical form of the joint and is most commonly limited to excision, debridement, thermal chondroplasty and microfractures. This chapter will focus in new technologies to enhance the standard techniques. These new technologies are based in stem cells therapies; as intra-articular injections of expanded mesenchymal stem cells, mononuclear conc...

  10. Pertunjukan Teater Karo Hip Hop Kontemporer KAI

    OpenAIRE

    Silvia Anggreni Purba

    2013-01-01

    Pertunjukan ini berawal dari sebuah ide untuk mengkolaborasikan tradisi Karo dengan budaya populer. Dengan cara seperti ini pertunjukan bisa dinikmati tanpa batasan bahasa dan budaya. Proses menggabungkan dua budaya yang berbeda merupakan bentuk budaya hibrida dan terjadi akibat proses globalisasi. Melalui proses pengendapan pengamatan dan kesan yang kuat, pertunjukan ini dibawa ke dalam bentuk Hip Hop. Pertunjukan ini merupakan bagian dari sebuah tragedi modern dengan karakter destruktif, me...

  11. Imaging of hip arthroplasty; Bildgebung bei Hueftprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, M.J. [Abteilung fuer Osteologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Klinische Abteilung fuer Radiodiagnostik chirurgischer Faecher, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Ludwig-Boltzmann-Institut fuer Radiologische Tumordiagnostik, Wien (Austria); Mayerhoefer, M. [Klinische Abteilung fuer Radiodiagnostik chirurgischer Faecher, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Gottsauner-Wolf, F. [Universitaetsklinik fuer Orthopaedie, Wien (Austria); Abteilung fuer Orthopaedie, Allgemeines oeffentliches KH, Krems (Austria); Krestan, C.; Imhof, H. [Abteilung fuer Osteologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Toma, C.D. [Universitaetsklinik fuer Orthopaedie, Wien (Austria)

    2002-06-01

    Hip arthroplasty has become a common and still increasing procedure for the treatment of osteoarthritis, advanced head necrosis, post-inflammatory arthritis or rheumatoid arthritis.Radiography is the most important imaging modality for monitoring the normal, asymptomatic hip arthroplasty. Radiographs are obtained at the end of a surgical treatment, to exclude complications like fracture or component misplacement. In the follow-up radiographs are used for the diagnosis of loosening and infection of the hip arthroplasty as well as soft tissue ossification. Together with the history and clinical information, the analysis of morphological findings allows to find the grade of loosening. MRI has been advocated in the diagnosis of infection, in particular in the localisation of soft tissue involvement.Imaging, especially by radiographs, is used for the evaluation of the normal and complicated follow-up of hip arthroplasty. (orig.) [German] Die Implantation einer Hueftgelenkprothese ist eine immer haeufiger verwendete medizinische Massnahme bei Erkrankungen des Hueftgelenks wie Koxarthrose, Hueftkopfnekrose, postentzuendliche Arthrose oder rheumatoide Arthritis.Von den bildgebenden Methoden ist das konventionelle Roentgen die wichtigste Untersuchung, um den normalen Behandlungsverlauf einer Hueftprothese zu monitieren. Das Roentgen kann fruehzeitige Komplikationen wie Fraktur oder Fehlposition intraoperativ oder eine Luxation postoperativ erfassen. Im laengerfristigen Verlauf ist das Roentgen zur Diagnose von Infektion, Prothesenlockerung und Weichteilverknoecherung geeignet. In Zusammenschau mit der Klinik ermoeglicht die Analyse morphologisch-radiologischer Details, die Wahrscheinlichkeit einer Lockerung abzuschaetzen. Bei Protheseninfektionen ermoeglicht die MRT die Lokalisation von Weichteilentzuendungen.Die Methoden der Bildgebung, besonders das Roentgen, haben in der Beurteilung des normalen und in der Diagnose des komplizierten Verlaufes einen hohen Stellenwert

  12. Fracture of femoral total hip replacement components

    International Nuclear Information System (INIS)

    The biomechanical factors responsible for fatigue fracture of femoral total hip component stems were studied by laboratory loading simulations using implants which were instrumented with strain gauges. Stress levels were low when the prosthesis was rigidly fixed in acrylic along its entire length. Significantly higher stresses were recorded in stems which were loose in the acrylic or which were fixed in their distal portion only

  13. Uudised : Pop-karneval. Hip-hop

    Index Scriptorium Estoniae

    2005-01-01

    Muusika- ja kunstikarnevalist "Beta Bubble" 1. apr. Tallinnas Von Krahlis. Pärnu taasühinenud hip-hop-bänd Noizmakaz (TommyBoy ja Alko) sõlmis lepingu plaadifirmaga Mindnote ja annab selle alt apr. keskel välja oma teise albumi "Valitud mõtted".1. apr. tuleb müügile Noizmakazi singel "Miski muu ei loe", debüüt "Social Poetry" ilmus aastal 2001

  14. Cementless isoelastic RM total hip prosthesis1

    OpenAIRE

    Bombelli, Renato; Mathys, Robert

    1982-01-01

    Some surgeons are beginning to doubt the reliability of bone cement in joint replacements. In 1967 Robert Mathys conceived the idea of an isoelastic prosthesis made of plastic, which would anchor into the bone without cement. He developed the idea by extensive tests in animals and, in 1973, the first human RM cementless hip prosthesis was inserted by E Morscher. In this paper the concept of the cementless isoelastic prosthesis is developed by Robery Mathys, and Professor Bombelli records his ...

  15. Medical images of the hip joint

    International Nuclear Information System (INIS)

    Up-to date techniques of sectional imaging of selected planes and ultrasonic methods have contributed considerably to improved diagnostic accuracy in the identification of hip joint anomalies in infants. Even though these innovations deserve to be valued highly the more conventional diagnostic methods are far from being superfluous and continue to be used on a routine basis in radiology. The relevant methods of focussing and ranges of use for standard and special projections are therefore surveyed in the following. (orig./GDG)

  16. The anatomy of the hip abductor muscles.

    Science.gov (United States)

    Flack, N A M S; Nicholson, H D; Woodley, S J

    2014-03-01

    The anatomy of the hip abductors has not been comprehensively examined, yet is important to understanding function and pathology in the gluteal region. For example, pathology of the hip abductor muscle-tendon complexes can cause greater trochanteric pain syndrome, and may be associated with gluteal atrophy and fatty infiltration. The purpose of this study was to investigate the detailed morphology of gluteus medius (GMed), gluteus minimus (GMin), and tensor fascia lata (TFL), and determine whether the muscles comprised anatomical compartments. The gluteal region from 12 cadavers was dissected and data collected on attachment sites, volume, fascicular and tendinous anatomy, and innervation. Three sites of GMed origin were identified (gluteal fossa, gluteal aponeurosis, and posteroinferior edge of the iliac crest) and the distal tendon had lateral and posterior parts. GMed was the largest in volume (27.6 ± 11.6 cm(3); GMin 14.1 ± 11.1 cm(3); TFL 1.8 ± 0.8 cm(3)). Fascicles of GMin originated from the gluteal fossa, inserting onto the deep surface of its distal tendon and the hip joint capsule. TFL was encapsulated in the fascia lata, having no bony attachment. Primary innervation patterns varied for GMed, with three or four branches supplying different regions of muscle. Distinct secondary nerve branches entered four regions of GMin; no differential innervation was observed for TFL. On the basis of architectural parameters and innervation, GMed, and GMin each comprise of four compartments but TFL is a homogenous muscle. It is anticipated that these data will be useful for future clinical and functional studies of the hip abductors. PMID:23625344

  17. Future Bearing Surfaces in Total Hip Arthroplasty

    OpenAIRE

    Chang, Jun-Dong

    2014-01-01

    One of the most important issues in the modern total hip arthroplasty (THA) is the bearing surface. Extensive research on bearing surfaces is being conducted to seek an ideal bearing surface for THA. The ideal bearing surface for THA should have superior wear characteristics and should be durable, bio-inert, cost-effective, and easy to implant. However, bearing surfaces that are currently being implemented do not completely fulfill these requirements, especially for young individuals for whom...

  18. Diagnostic value of bone scintigraphy with sup(99m)Tc-pyrophosphate for evaluation of complications after hip joint replacement

    International Nuclear Information System (INIS)

    For 102 patients with complaints after total hip replacement, bone scintigraphies with sup(99m)Tc have been made in addition to the usual examinations. 95 of these patients had to be operated once more, whereas the infected endoprosteses detected in the remaining 7 patients have been treated for the time being by non-surgical measures. In 68 patients, the examination revealed an aseptic loosening of the total endoprosthesis, including fracture of the diaphysis in 19 cases. In one case, a replacement of the prosthesis had been necessary in spite of the alloarthroplasty being firmly fixed in the right place. The bacterioscopic and bacteriologic investigations clearly revealed an infection of the environment of the prosthesis, in 27 patients, whereas the findings obtained on 6 other patients have not been as unambiguons. 85% of the patients with septic complications showed an increased E.S.R., however only 26% of the patients with aseptic complications. In only 47% of the patients with infection of the hip joint, bacteria have been found in the hip joint puncture fluid, whereas the bacteriological examination of tissue taken from the environment of the artificial hip joint during the operation revealed no increase in bacteria in only one case (5%). In 4 patients (20%), the bacterioscopic findings showed no signs of an acute infection, although saprophytic germs had been isolated from the environment of the prosthesis. 78% of the cases with loosening of the prosthesis and 11% of the infections have been detected by X-ray examination. The nuclear medical examination showed normal radionuclide accumulation in 30% of the cases with loosened prosthesis and in 4% of the infections, for 6% each of the two complications the scintigrams yielded no unambiguous results. In 4 patients (40%) with total hip joint replacement on both sides, enhanced radionuclide accumulation has been abserved even on the symptom-free side. (orig./AJ)

  19. Imaging of neuropathies about the hip

    International Nuclear Information System (INIS)

    Neuropathies about the hip may be cause of chronic pain and disability. In most cases, these conditions derive from mechanical or dynamic compression of a segment of a nerve within a narrow osteofibrous tunnel, an opening in a fibrous structure, or a passageway close to a ligament or a muscle. Although the evaluation of nerve disorders primarily relies on neurological examination and electrophysiology, diagnostic imaging is currently used as a complement to help define the site and aetiology of nerve compression and exclude other disease possibly underlying the patient’ symptoms. Diagnosis of entrapment neuropathies about the hip with US and MR imaging requires an in-depth knowledge of the normal imaging anatomy and awareness of the anatomic and pathologic factors that may predispose or cause a nerve injury. Accordingly, the aim of this article is to provide a comprehensive review of hip neuropathies with an emphasis on the relevant anatomy, aetiology, clinical presentation, and their imaging appearance. The lateral femoral cutaneous neuropathy (meiralgia paresthetica), femoral neuropathy, sciatic neuropathy, obturator neuropathy, superior and inferior gluteal neuropathies and pudendal neuropathy will be discussed

  20. Friction measurement in a hip wear simulator.

    Science.gov (United States)

    Saikko, Vesa

    2016-05-01

    A torque measurement system was added to a widely used hip wear simulator, the biaxial rocking motion device. With the rotary transducer, the frictional torque about the drive axis of the biaxial rocking motion mechanism was measured. The principle of measuring the torque about the vertical axis above the prosthetic joint, used earlier in commercial biaxial rocking motion simulators, was shown to sense only a minor part of the total frictional torque. With the present method, the total frictional torque of the prosthetic hip was measured. This was shown to consist of the torques about the vertical axis above the joint and about the leaning axis. Femoral heads made from different materials were run against conventional and crosslinked polyethylene acetabular cups in serum lubrication. Regarding the femoral head material and the type of polyethylene, there were no categorical differences in frictional torque with the exception of zirconia heads, with which the lowest values were obtained. Diamond-like carbon coating of the CoCr femoral head did not reduce friction. The friction factor was found to always decrease with increasing load. High wear could increase the frictional torque by 75%. With the present system, friction can be continuously recorded during long wear tests, so the effect of wear on friction with different prosthetic hips can be evaluated. PMID:27160557

  1. Imaging of neuropathies about the hip

    Energy Technology Data Exchange (ETDEWEB)

    Martinoli, Carlo, E-mail: carlo.martinoli@unige.it [Radiologia – DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Miguel-Perez, Maribel [Unit of Human Anatomy and Embryology, Department of Pathology and Experimental Therapy, Faculty of Medicine (C Bellvitge), University of Barcelona, Barcelona (Spain); Padua, Luca [Fondazione Don Gnocchi Onlus and Department of Neurology, Policlinico “A. Gemelli”, Università Cattolica del Sacro Cuore, Rome (Italy); Gandolfo, Nicola [IM2S – Institut Monégasque de Médecine and Chirurgie Sportive, Montecarlo (Monaco); Zicca, Anna [Radiologia – DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Tagliafico, Alberto [Radiologia – National Institute for Cancer Research, Genoa (Italy)

    2013-01-15

    Neuropathies about the hip may be cause of chronic pain and disability. In most cases, these conditions derive from mechanical or dynamic compression of a segment of a nerve within a narrow osteofibrous tunnel, an opening in a fibrous structure, or a passageway close to a ligament or a muscle. Although the evaluation of nerve disorders primarily relies on neurological examination and electrophysiology, diagnostic imaging is currently used as a complement to help define the site and aetiology of nerve compression and exclude other disease possibly underlying the patient’ symptoms. Diagnosis of entrapment neuropathies about the hip with US and MR imaging requires an in-depth knowledge of the normal imaging anatomy and awareness of the anatomic and pathologic factors that may predispose or cause a nerve injury. Accordingly, the aim of this article is to provide a comprehensive review of hip neuropathies with an emphasis on the relevant anatomy, aetiology, clinical presentation, and their imaging appearance. The lateral femoral cutaneous neuropathy (meiralgia paresthetica), femoral neuropathy, sciatic neuropathy, obturator neuropathy, superior and inferior gluteal neuropathies and pudendal neuropathy will be discussed.

  2. Plastazote abduction orthosis in the management of neonatal hip instability.

    Science.gov (United States)

    Eberle, Charles F

    2003-01-01

    Since 1987, 113 consecutive newborns with either Ortolani-positive or provocative-positive hip examinations in the newborn nursery have been treated with a Plastazote hip abduction orthosis when diagnosed and followed to determine if the method was safe, effective, and easy to use. Ortolani-positive hips often had bilateral abnormalities in the hip examination, were frequently associated with breech position, and were anatomically more dysplastic than those hips that were unstable by provocative testing. No patient developed ischemic necrosis during follow-up. Only two had additional treatment of their unstable hips. The rest had excellent results. Parents and caregivers found the device easy to use. The orthosis is recommended as the primary method for managing newborns with clinical instability to either the provocative or Ortolani test as being safe, effective, and easy to use across all skill levels. PMID:12960623

  3. Normative values of eccentric hip abduction strength in novice runners

    DEFF Research Database (Denmark)

    Ramskov, D; Pedersen, M B; Kastrup, K;

    2014-01-01

    PURPOSE: Low eccentric strength of the hip abductors, might increase the risk of patellofemoral pain syndrome and iliotibial band syndrome in runners. No normative values for maximal eccentric hip abduction strength have been established. Therefore the purpose of this study was to establish...... normative values of maximal eccentric hip abduction strength in novice runners. METHODS: Novice healthy runners (n = 831) were recruited through advertisements at a hospital and a university. Maximal eccentric hip abduction strength was measured with a hand-held dynamometer. The demographic variables...... associated with maximal eccentric hip abduction strength from a univariate analysis were included in a multivariate linear regression model. Based on the results from the regression model, a regression equation for normative hip abduction strength is presented. RESULTS: A SIGNIFICANT DIFFERENCE IN MAXIMAL...

  4. Evaluation of Two Total Hip Bearing Materials for Resistance to Wear Using a Hip Simulator

    Directory of Open Access Journals (Sweden)

    Kenneth R. St. John

    2015-06-01

    Full Text Available Electron beam crosslinked ultra high molecular weight polyethylene (UHMWPE 32 mm cups with cobalt alloy femoral heads were compared with gamma-irradiation sterilized 26 mm cups and zirconia ceramic heads in a hip wear simulator. The testing was performed for a total of ten million cycles with frequent stops for cleaning and measurement of mass losses due to wear. The results showed that the ceramic on UHMWPE bearing design exhibited higher early wear than the metal on highly crosslinked samples. Once a steady state wear rate was reached, the wear rates of the two types of hip bearing systems were similar with the ceramic on UHMPWE samples continuing to show a slightly higher rate of wear than the highly crosslinked samples. The wear rates of each of the tested systems appear to be consistent with the expectations for low rates of wear in improved hip replacement systems.

  5. Clinical and radiological evaluation of hybrid hip replacement in various disorders of hip

    Directory of Open Access Journals (Sweden)

    Dhaon B

    2005-01-01

    Full Text Available Background: High rates of loosening of cemented implants led to change in technique of fixation of the implant. Methods: Fifty-nine hips were operated in 42 patients with non-cemented acetabular and cemented femoral components between January 1999 and July 2003. The average age of the patient was 45.2 years in our study. Preoperative diagnosis was avascular necrosis (28, ankylosing spondylitis (18, fracture neck femur (9, rheumatoid arthritis (2 and osteoarthritis (2. Results: At an average follow up of 3.6 years (range 1.2-5.8 years excellent to good results were obtained 92% according to Harris hip criteria. No radiological loosening was noted in any femoral or acetabular component on follow up. One poor result was seen in a case of bilateral ankylosing spondylitis operated on one side. Conclusion: Hybrid THA provides a viable and highly acceptable method of treatment of diseases of hip in young patients.

  6. Artificial intelligence in hematology.

    Science.gov (United States)

    Zini, Gina

    2005-10-01

    Artificial intelligence (AI) is a computer based science which aims to simulate human brain faculties using a computational system. A brief history of this new science goes from the creation of the first artificial neuron in 1943 to the first artificial neural network application to genetic algorithms. The potential for a similar technology in medicine has immediately been identified by scientists and researchers. The possibility to store and process all medical knowledge has made this technology very attractive to assist or even surpass clinicians in reaching a diagnosis. Applications of AI in medicine include devices applied to clinical diagnosis in neurology and cardiopulmonary diseases, as well as the use of expert or knowledge-based systems in routine clinical use for diagnosis, therapeutic management and for prognostic evaluation. Biological applications include genome sequencing or DNA gene expression microarrays, modeling gene networks, analysis and clustering of gene expression data, pattern recognition in DNA and proteins, protein structure prediction. In the field of hematology the first devices based on AI have been applied to the routine laboratory data management. New tools concern the differential diagnosis in specific diseases such as anemias, thalassemias and leukemias, based on neural networks trained with data from peripheral blood analysis. A revolution in cancer diagnosis, including the diagnosis of hematological malignancies, has been the introduction of the first microarray based and bioinformatic approach for molecular diagnosis: a systematic approach based on the monitoring of simultaneous expression of thousands of genes using DNA microarray, independently of previous biological knowledge, analysed using AI devices. Using gene profiling, the traditional diagnostic pathways move from clinical to molecular based diagnostic systems. PMID:16203606

  7. Viscosupplementation in the hip: evaluation of hyaluronic acid formulations

    OpenAIRE

    van den Bekerom, M. P. J.; Rys, B.; Mulier, M.

    2007-01-01

    This study compares three different hyaluronate formulations and evaluates functionality, time of satisfactory pain relief and also the delay in performing a total hip arthroplasty. One hundred and twenty patients (126 hips) received viscosupplementation with one of the three hyaluronate formulations. All patients were candidate for surgical treatment with a total hip arthroplasty. Three different products were consecutively used: Adant®, Synocrom® or Synvisc®. Patients were assessed 6 weeks ...

  8. Outcome after osteosynthesis of hip fractures in nonagenarians

    OpenAIRE

    de Leur K; Vroemen JP; DI Vos; Elmans L; van der Laan L

    2013-01-01

    Kevin de Leur,1 Jos P A M Vroemen,1 Dagmar I Vos,1 Leon Elmans,2 Lijckle van der Laan1 1Department of Surgery, 2Orthopedics, Amphia Hospital, Breda, The Netherlands Background: Hip fractures in the elderly population are associated with high morbidity and mortality. However, there is still a lack of information on mortality and loss of independence in extremely elderly people with a hip fracture. Objective: To study functional outcomes and mortality after osteosynthesis of hip fractures in v...

  9. Component Alignment in Hip Resurfacing Using Computer Navigation

    OpenAIRE

    Bailey, Chris; Gul, Rehan; Falworth, Mark; Zadow, Steven; Oakeshott, Roger

    2008-01-01

    The use of computer navigation during hip resurfacing has been proposed to reduce the risk of a malaligned component and notching with subsequent postoperative femoral neck fracture. Femoral component malalignment and notching have been identified as the major factors associated with femoral neck fracture after hip resurfacing. We performed 37 hip resurfacing procedures using an imageless computer navigation system. Preoperatively, we generated a patient-specific computer model of the proxima...

  10. Muscle mass and function after total hip arthroplasty

    OpenAIRE

    Rasch, Anton

    2009-01-01

    Osteoarthritis (OA) of the hip is a common disease among elderly causing pain, joint stiffness and reduced mobility. Outcome studies have shown total hip arthroplasy (THA) to be a successful surgical procedure. Studies of muscle strength and function after THA are more scarce and results vary. It has been suggested that unloading of the OA limb due to pain, results in hip and thigh muscle weakness and atrophy causing an abnormal gait and impaired postural control. Muscle atr...

  11. Do pessimists report worse outcomes after total hip arthroplasty?

    OpenAIRE

    Singh, Jasvinder A; Colligan, Robert C.; O’Byrne, Megan M.; David G Lewallen

    2016-01-01

    Background Seligman’s theory of causal attribution predicts that patients with a pessimistic explanatory style will have less favorable health outcomes. We investigated this hypothesis using self-reported hip pain and hip function 2- years after total hip arthroplasty (THA). Methods Most THA patients had completed the Minnesota Multiphasic Personality Inventory (MMPI) during their usual clinical care long before THA (median, 14.7 to 16.6 years). Scores from the MMPI Optimism-Pessimism (PSM) s...

  12. Imaging of Sports-Related Hip and Groin Injuries

    OpenAIRE

    Lischuk, Andrew W.; Dorantes, Thomas M.; Wong, William; Haims, Andrew H.

    2010-01-01

    A normally functioning hip joint is imperative for athletes who use their lower extremities with running, jumping, or kicking activities. Sports-related injuries of the hip and groin are far less frequent than injuries to the more distal aspect of the extremity, accounting for less than 10% of lower extremity injuries. Despite the lower incidence, hip and groin injuries can lead to significant clinical and diagnostic challenges related to the complex anatomy and biomechanical considerations o...

  13. CONGENITAL DISLOCATION OF RIGHT HIP JOINT: IMPORTANCE OF DYNAMIC ASSESSMENT

    OpenAIRE

    Pranita viveki; R. G. Viveki

    2014-01-01

    Congenital Dislocation of Hip (CDH), is one of the most common congenital diseases in the orthopedic field. It is also known as Developmental Dysplasia of Hip. The condition can be diagnosed by clinical, ultrasonographic and radiological examination. Here we are reporting two days old male baby with congenital dislocation of right hip joint. The goal of treatment is to obtain a reduction to provide an optimal environment for femoral head and acetabular development. Early diagnosis is the mo...

  14. Differential Genetic Regulation of Canine Hip Dysplasia and Osteoarthritis

    OpenAIRE

    Zhengkui Zhou; Xihui Sheng; Zhiwu Zhang; Keyan Zhao; Lan Zhu; Gang Guo; Steve G Friedenberg; Hunter, Linda S.; Vandenberg-Foels, Wendy S.; Hornbuckle, William E.; Ursula Krotscheck; Elizabeth Corey; Moise, Nancy S.; Dykes, Nathan L.; Junya Li

    2010-01-01

    BACKGROUND: Canine hip dysplasia (HD) is a common polygenic trait characterized by hip malformation that results in osteoarthritis (OA). The condition in dogs is very similar to developmental dysplasia of the human hip which also leads to OA. METHODOLOGY/PRINCIPAL FINDINGS: A total of 721 dogs, including both an association and linkage population, were genotyped. The association population included 8 pure breeds (Labrador retriever, Greyhounds, German Shepherd, Newfoundland, Golden retriever,...

  15. The influence of heterotopic ossification on functional status of hip joint following total hip arthroplasty

    International Nuclear Information System (INIS)

    Purpose: The functional failure induced by heterotopic ossification (HO) following total hip arthroplasty (THA) was analyzed and correlated to the radiologic failure. Patients and methods: From July 1997 to July 2001, 315 patients (345 hips) received THA indicated by a hypertrophic osteoarthritis of higher degree (Kellgren grade III, IV). All patients were irradiated prophylactically for prevention of HO on the evening before surgery with a 7-Gy single fraction. The patients' median age was 66.3 years. Radiologic failure was assessed by comparison of pre- and postoperative hip X-rays (immediately and 6 months after surgery). Analysis of radiographs was performed according to the Brooker Score. Clinical failure was appraised by measurement of passive range of motion (ROM) of the hip joint with a standard goniometer. The t-test was used for statistical analysis. Results: 281 patients (81.5%) did not develop HO. HO of Brooker grade I or II was found in 58 patients (16.8%). Six patients (1.7%) developed HO Brooker grade III or IV. There was a significant negative correlation between the degree of radiologic and clinical failure. ROM differed significantly between patients with HO Brooker grade 0, I, II and patients with HO Brooker grade III, IV. Comparing the pre- and postoperative ROM, all patients with Brooker grade 0, I and II showed a significant improvement of flexion, internal and external rotation, abduction and adduction movement. Patients with HO Brooker grade III and IV showed no improvement of ROM in the postoperative follow-up. Conclusion: The development of HO following THA influences the physical function of the hip joint dependent on the degree of ossification. HO of lower degree (Brooker I, II) does not influence the clinical outcome, whereas HO of higher degree (Brooker III, IV) reduces the function of hip arthroplasty. Therefore, the purpose of a prophylactic therapy must be to reduce HO of higher degree. (orig.)

  16. A Water Rehabilitation Program in Patients with Hip Osteoarthritis Before and After Total Hip Replacement

    Science.gov (United States)

    Łyp, Marek; Kaczor, Ryszard; Cabak, Anna; Tederko, Piotr; Włostowska, Ewa; Stanisławska, Iwona; Szypuła, Jan; Tomaszewski, Wiesław

    2016-01-01

    Background Pain associated with coxarthrosis, typically occurring in middle-aged and elderly patients, very commonly causes considerable limitation of motor fitness and dependence on pharmacotherapy. This article provides an assessment of a rehabilitation program with tailored water exercises in patients with osteoarthritis before and after total hip replacement. Material/Methods A total of 192 patients (the mean age 61.03±10.89) suffering from hip osteoarthritis (OA) were evaluated before and after total hip replacement (THR). The clinical study covered measurements of hip active ranges of motion (HAROM) and the forces generated by pelvis stabilizer muscles. Pain intensity was assessed according to analogue-visual scale of pain (VAS) and according to the Modified Laitinen Questionnaire. The patients were divided into 6 groups (4 treatment and 2 control). We compared 2 rehabilitation programs using kinesitherapy and low-frequency magnetic field. One of them also had specially designed exercises in the water. Statistical analysis was carried out at the significance level α=0.05. This was a cross-sectional study. Results A positive effect of water exercises on a number of parameters was found in patients with OA both before and after total hip replacement surgery. We noted a significant reduction of pain (pdegree of degenerative deforming lesions and the effects of the treatment process (p<0.01). Conclusions 1. The rehabilitation program including water exercises most significantly reduced pain in patients with OA before and after total hip replacement surgery. 2. Inclusion of water exercises in a rehabilitation program can reduce the use of medicines in patient with OA and after THR. PMID:27455419

  17. Neurovascular lesion after total hip arthroplasty in congenital hip dysplasia: Case report

    Directory of Open Access Journals (Sweden)

    Stojković-Jovanović Tatjana

    2013-01-01

    Full Text Available Introduction. Nowadays, the total hip arthroplasty is a very frequent surgical intervention. In some cases, vascular and nerve injuries may happen around the hip with total hip arthroplasty. Although they are very rare, they may be very dangerous for the patient in some cases. This paper presents a case of a female patient, in whom the nervous fibularis lesion was detected after the total hip arthroplasty, and the occlusion of the iliac femoral artery was revealed later during physical therapy. Case Report. We described a case of a 32-year-old female patient, in whom the nervous fibularis lesion was detected after the total hip arthroplasty. The patient was referred to a ward for physical therapy. On the 19th postoperative day, she felt a vigorous ache and numbness on the left operated leg during stimulation of the paretic fibular musculature. Clinically weak inguinal arterial pulse was detected. After the examination, iliac-femoral occlusion was diagnosed. The patient was referred to the vascular surgeon. In the next few months, she was treated conservatively and eventually underwent surgery. The revascularization was achieved with a satisfactory effect. A year after the total hip replacement, the patient continued with rehabilitation and physical treatment, which lasted one and a half month and had an incomplete functional result - the patient walked with a walking stick and had weak fibular musculature of a severe degree. The vascular status of the leg was good. Conclusion. In this case, neurovascular lesions led to an incomplete functional recovery of the patient and compromised the expected treatment outcome. According to the scoring system used to assess the functionality, the result was marked as poor.

  18. Polymer artificial muscles

    Directory of Open Access Journals (Sweden)

    Tissaphern Mirfakhrai

    2007-04-01

    Full Text Available The various types of natural muscle are incredible material systems that enable the production of large deformations by repetitive molecular motions. Polymer artificial muscle technologies are being developed that produce similar strains and higher stresses using electrostatic forces, electrostriction, ion insertion, and molecular conformational changes. Materials used include elastomers, conducting polymers, ionically conducting polymers, and carbon nanotubes. The mechanisms, performance, and remaining challenges associated with these technologies are described. Initial applications are being developed, but further work by the materials community should help make these technologies applicable in a wide range of devices where muscle-like motion is desirable.

  19. Uncertainty in artificial intelligence

    CERN Document Server

    Kanal, LN

    1986-01-01

    How to deal with uncertainty is a subject of much controversy in Artificial Intelligence. This volume brings together a wide range of perspectives on uncertainty, many of the contributors being the principal proponents in the controversy.Some of the notable issues which emerge from these papers revolve around an interval-based calculus of uncertainty, the Dempster-Shafer Theory, and probability as the best numeric model for uncertainty. There remain strong dissenting opinions not only about probability but even about the utility of any numeric method in this context.

  20. Bayesian artificial intelligence

    CERN Document Server

    Korb, Kevin B

    2010-01-01

    Updated and expanded, Bayesian Artificial Intelligence, Second Edition provides a practical and accessible introduction to the main concepts, foundation, and applications of Bayesian networks. It focuses on both the causal discovery of networks and Bayesian inference procedures. Adopting a causal interpretation of Bayesian networks, the authors discuss the use of Bayesian networks for causal modeling. They also draw on their own applied research to illustrate various applications of the technology.New to the Second EditionNew chapter on Bayesian network classifiersNew section on object-oriente

  1. Mechanism of artificial heart

    CERN Document Server

    Yamane, Takashi

    2016-01-01

    This book first describes medical devices in relation to regenerative medicine before turning to a more specific topic: artificial heart technologies. Not only the pump mechanisms but also the bearing, motor mechanisms, and materials are described, including expert information. Design methods are described to enhance hemocompatibility: main concerns are reduction of blood cell damage and protein break, as well as prevention of blood clotting. Regulatory science from R&D to clinical trials is also discussed to verify the safety and efficacy of the devices.

  2. Results of hip resurfacing for developmental dysplasia of the hip of Crowe type Ⅰ and Ⅱ

    Institute of Scientific and Technical Information of China (English)

    XU Wei-dong; LI Jia; ZHOU Zhen-hua; WU Yue-song; LI Ming

    2008-01-01

    Background Recently, the new generation of metal-on-metal total hip resurfacing arthroplasty is well known for preserving the proximal femoral bone stock, minimizing the risk of postoperative dislocation using large femoral heads, and expecting low wear of metal-on-metal articulation for longer prosthesis survival. It also has the advantage in biomechanical loading in the proximal femur. The osteoarthritis secondary to developmental dysplasia of the hip (DDH) has been the most common reason for total hip arthroplasty. Most of the patients are young and active, who require improved range of motion of the hip besides relief of the pain, even expect to resume the ability to run and jump after the joint arthroplasty, thus to be allowed an active lifestyle. The objective of the current study was to evaluate the early outcome of resurfacing arthroplasty for the mild DDH cases (Crowe type Ⅰ and Ⅱ).Methods Between September 2005 and May 2007, twenty-one consecutive patients (twenty-six hips) with the diagnosis of osteoarthritis secondary to DDH underwent metal-on-metal resurfacing arthroplasty. The average age at the time of surgery was 46.5 years (range, 37-59 years). Six patients (28.6%) were male and fifteen (71.4%) were female. Clinical and radiographic results were observed. The follow-up was performed at 6 weeks, 3, 6, 9 months and then yearly.Results All patients were followed for a mean of 18 months (9-29 months). During the follow-up period no complications, such as dislocation of hip joints, infection or femoral neck fracture occurred. The clinical outcomes, as rated with the Harris hip score, improved significantly compared with the preoperative ratings. The mean postoperative Harris hip score was 90.7, compared to 35.5 preoperatively. The radiographic analysis showed that all prostheses were fixed with no radiolucencies. All of the patients who had equal limb lengths preoperatively had equal lengths postoperatively. Of the nine patients with preoperative

  3. MR findings of transient synovitis of the hip

    International Nuclear Information System (INIS)

    To evaluate the MR findings of transient synovitis of the hip in children. Between 1993 and 1997, MR imaging was performed in 30 children (male:female 22:8) in whom transient synovitis had been clinically diagnosed. In 20 of these 30 patients, Gd-enhanced study was also performed. The signal intensity of bone marrow of the femur, the synovial enhancement pattern and the amount of hip joint effusion in affected hips were evaluated; the last -mentioned was determined using the volume measurement method. In 29 patients (97%), no abnormal signal intensity was seen in bone marrow of the femur in affected hips. Gd-enhanced MR imaging revealed synovial enhancement of affected hip joints, as follows: minimal enhancement in eight patients (40%), moderate enhancement in eight (40%), and strong enhancement in four (20%). No abnormal enhancement was demonstrated in bone marrow of the femur or adjacent soft tissue. The mean amount of joint effusion of affected hips was 2.7±1.7 (range, 0.2-18.9)ml; statistically, this was much greater than that of contralateral hip (p less than 0.01). The MR findings of transient synovitis of the hip in children were normal bone marrow signal intensity of the femoral head, moderate or strong synovial enhancement, and asymmetric hip joint effusion. (author)

  4. Postoperative pain after hip fracture is procedure specific

    DEFF Research Database (Denmark)

    Foss, Nicolai; Palm, H; Kehlet, H; Foss, Nicolai Bang; Kristensen, Morten Tange; Palm, Henrik; Kehlet, Henrik

    2009-01-01

    . Patients were stratified into four groups according to surgical procedure: screws or pins, arthroplasty, dynamic hip screw (DHS), and intra-medullary hip screw (IMHS). RESULTS: Cumulated pain levels were significantly different between surgical procedures both for hip flexion (P=0.002) and for walking (P=0.......02) with highest dynamic pain levels for patients who had either DHSs or IMHSs compared with arthroplasty or parallel implants. There were significant negative correlations between ambulatory capacity assessed by the cumulated ambulation score and both the dynamic cumulated pain scores on hip flexion (r=-0...

  5. Traumatic hip dislocation with associated femoral head fracture

    DEFF Research Database (Denmark)

    Dortaj, H; Emamifar, A

    2015-01-01

    Dislocation of the hip is a critical injury that results from high-energy trauma. This paper describes a case of posterior dislocation of the right hip in a 35-year-old woman with associated ipsilateral femoral head fracture. Initial treatment included reduction of the right hip through posterior...... approach and fixation of the femoral head fracture with three absorbable screws. After 15-month follow-up, a full range of motion has been achieved and there are no signs of avascular necrosis, hip instability, or limping. The authors describe their method of surgery....

  6. Characteristics of children with hip displacement in cerebral palsy

    Directory of Open Access Journals (Sweden)

    Wagner Philippe

    2007-10-01

    Full Text Available Abstract Background Hip dislocation in children with cerebral palsy (CP is a common and severe problem. The dislocation can be avoided, by screening and preventive treatment of children with hips at risk. The aim of this study was to analyse the characteristics of children with CP who develop hip displacement, in order to optimise a hip surveillance programme. Methods In a total population of children with CP a standardised clinical and radiological follow-up of the hips was carried out as a part of a hip prevention programme. The present study is based on 212 children followed until 9–16 years of age. Results Of the 212 children, 38 (18% developed displacement with Migration Percentage (MP >40% and further 19 (9% MP between 33 and 39%. Mean age at first registration of hip displacement was 4 years, but some hips showed MP > 40% already at two years of age. The passive range of hip motion at the time of first registration of hip displacement did not differ significantly from the findings in hips without displacement. The risk of hip displacement varied according to CP-subtype, from 0% in children with pure ataxia to 79% in children with spastic tetraplegia. The risk of displacement (MP > 40% was directly related to the level of gross motor function, classified according to the gross motor function classification system, GMFCS, from 0% in children in GMFCS level I to 64% in GMFCS level V. Conclusion Hip displacement in CP often occurs already at 2–3 years of age. Range of motion is a poor indicator of hips at risk. Thus early identification and early radiographic examination of children at risk is of great importance. The risk of hip displacement varies according to both CP-subtype and GMFCS. It is sometimes not possible to determine subtype before 4 years of age, and at present several definitions and classification systems are used. GMFCS is valid and reliable from 2 years of age, and it is internationally accepted. We recommend a hip

  7. Comparison of three methods to diagnose hip dysplasia in dogs

    International Nuclear Information System (INIS)

    The present study was designed to compare the usefulness of goniometry, radiography and distraction index in diagnosis of hip dysplasia in dogs. During the study 25 clinical cases (50 joints) suspected for hip dysplasia were evaluated. Norberg angle was found to have a significant positive correlation with extension, flexion, abduction, and adduction angles and a significant negative correlation with distraction index (DI) measurements. It could be inferred that all the six parameters (NA, DI, extension, flexion, abduction, and adduction) were reliable indicators for early diagnosis of hip dysplasia.Goniometry could be used as a safe and easy method for preliminary suspicion of hip dysplasia

  8. Effects of Compliance on Trunk and Hip Integrative Neuromuscular Training on Hip Abductor Strength in Female Athletes

    OpenAIRE

    Sugimoto, Dai; Myer, Gregory D; Bush, Heather M.; Hewett, Timothy E.

    2014-01-01

    Sugimoto, D, Myer, GD, Bush, HM, and Hewett, TE. Effects of compliance on trunk and hip integrative neuromuscular training on hip abductor strength in female athletes. Recent studies demonstrate the link between reduced hip abductor strength and increased risk for knee injury such as patellofemoral pain syndrome in women athletes. Meta-analytic reports indicate that the efficacy of integrative neuromuscular training (INT) is associated with compliance to the prescribed programming. Thus, the ...

  9. Outcome of total hip arthroplasty as a salvage procedure for failed infected internal fixation of hip fractures

    OpenAIRE

    Shubhranshu S Mohanty; Agashe, Mandar V.; Sheth, Binoti A; Kumar K. Dash

    2013-01-01

    Background: Failed infected internal fixation produces significant pain and functional disability. In infected internal fixation of hip fractures with partial or complete head destruction, total hip arthroplasty (THA) can be technically challenging; however, it restores hip biomechanics. The present study is to evaluate the results and assess the complications of THA following failed infected internal fixation of these fractures. Materials and Methods: A retrospective review of prospectiv...

  10. Artificial organs: recent progress in artificial hearing and vision.

    Science.gov (United States)

    Ifukube, Tohru

    2009-01-01

    Artificial sensory organs are a prosthetic means of sending visual or auditory information to the brain by electrical stimulation of the optic or auditory nerves to assist visually impaired or hearing-impaired people. However, clinical application of artificial sensory organs, except for cochlear implants, is still a trial-and-error process. This is because how and where the information transmitted to the brain is processed is still unknown, and also because changes in brain function (plasticity) remain unknown, even though brain plasticity plays an important role in meaningful interpretation of new sensory stimuli. This article discusses some basic unresolved issues and potential solutions in the development of artificial sensory organs such as cochlear implants, brainstem implants, artificial vision, and artificial retinas. PMID:19330498

  11. Leg lengthening of more than 5 cm is a risk factor for sciatic nerve injury after total hip arthroplasty for adult hip dislocation

    OpenAIRE

    Higuchi, Yoshitoshi; Hasegawa, Yukiharu; Ishiguro, Naoki

    2015-01-01

    ABSTRACT Total hip arthroplasty (THA) in patients with high hip dislocation is challenging and technically demanding. Nerve injury is a problem associated with leg lengthening after THA. The purpose of this study was to identify the risk factors for sciatic nerve injury after THA in patients with high hip dislocation. Thirty-seven patients (41 THAs) with Crowe type IV hips were consecutively treated. The average leg lengthening (LL) was 3.2 cm. The average Harris hip score was improved from 5...

  12. Hip and pelvis diseases on lumbar AP radiographs including both hip joints

    International Nuclear Information System (INIS)

    To determine the frequency of disease, and to evaluate the methods used for lumbar spine radiography in Korea. Sixty university and training hospitals were randomly selected and asked to describe the projections, film size and radiographic techniques employed for routine radiography in patients with suspected disease of the lumbar spine. Plain radiographs of 1215 patients, taken using 14x17 inch film and depicting both hip joints and the lumbar region, were analysed between March 1999 and February 2000. In 15 patients (1.2%), the radiographs revealed hip or pelvic lesion, confirmed as follows: avascular necrosis of the femoral head (n=11, with bilateral lesion in four cases); sustained ankylosing spondylitis (n=2); acetabular dysplasia (n=1); and insufficiency fracture of the pubic rami secondary to osteoporosis (n=1). In 11 or the 20 hospitals which responded, 14x17film was being used for lumbar radiography, while in the other nine, film size was smaller. Plain radiography of the lumbar spine including both hip joints, may be a useful way to simultaneously evaluate lesions not only of the lumbar spine but also of the hip and/or pelvis

  13. Hip and pelvis diseases on lumbar AP radiographs including both hip joints

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyun Soo; Juhng, Seon Kwan; Kim, Eun A; Kim, Jeong Ho; Song, Ha Heon; Shim, Dae Moo [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2002-12-01

    To determine the frequency of disease, and to evaluate the methods used for lumbar spine radiography in Korea. Sixty university and training hospitals were randomly selected and asked to describe the projections, film size and radiographic techniques employed for routine radiography in patients with suspected disease of the lumbar spine. Plain radiographs of 1215 patients, taken using 14x17 inch film and depicting both hip joints and the lumbar region, were analysed between March 1999 and February 2000. In 15 patients (1.2%), the radiographs revealed hip or pelvic lesion, confirmed as follows: avascular necrosis of the femoral head (n=11, with bilateral lesion in four cases); sustained ankylosing spondylitis (n=2); acetabular dysplasia (n=1); and insufficiency fracture of the pubic rami secondary to osteoporosis (n=1). In 11 or the 20 hospitals which responded, 14{sup x}17{sup f}ilm was being used for lumbar radiography, while in the other nine, film size was smaller. Plain radiography of the lumbar spine including both hip joints, may be a useful way to simultaneously evaluate lesions not only of the lumbar spine but also of the hip and/or pelvis.

  14. Hip-Hop Is the Healer: Sense of Belonging and Diversity among Hip-Hop Collegians

    Science.gov (United States)

    Sulé, V. Thandi

    2016-01-01

    Sense of belonging is recognized as a factor contributing to persistence to graduation. Furthermore, interactional diversity is associated with learning and civic outcomes--touted higher education goals. Hip-hop culture, one of the most influential cultural creations of the mid-20th century, has succeeded in attracting devotees from diverse…

  15. Hip disability and osteoarthritis outcome score (HOOS)--validity and responsiveness in total hip replacement

    DEFF Research Database (Denmark)

    Nilsdotter, Anna K; Lohmander, L Stefan; Klässbo, Maria;

    2003-01-01

    The aim of the study was to evaluate if physical functions usually associated with a younger population were of importance for an older population, and to construct an outcome measure for hip osteoarthritis with improved responsiveness compared to the Western Ontario McMaster osteoarthritis score...

  16. Primary abductor hip contracture as diagnostic, prognostic and therapeutic problem in child hip pathology

    Directory of Open Access Journals (Sweden)

    Pajić Miloš

    2007-01-01

    Full Text Available Coxa obliqua represents a special functional entity in the pathology of the child hip. Authors have confirmed the results of S.L. Weissman and B. Strinovic which claimed that the abductor contracture of the hip was a primary congenital condition that developed as a result of intrauterine malposition, leading later to the contralateral adductor contracture. Critical period for the development of complications was between 6 and 8 month after birth, adductor contracture might keep persisting together with the development of acetabular dysplasia, and later on with ipsilateral subluxation. This malformation has usually been diagnosed within 3 and 6 months of age. It could be connected with some other signs of malposition, such as plagiocephaly, torticollis or infantile thoracic C scoliosis. For the diagnosis of coxa obliqua, the examination of hips in the prone position was very important and the ultrasonic and radiological examinations were crucial. The applied treatment used to be exclusively physical rehabilitation. Wide diapering has been contraindicated. In this study, we included 2,500 newborns, 1,300 boys and 1,200 girls (5,000 hips. In 22 cases of coxa obliqua (10‰, the excellent results were obtained in 96% of cases. In two unsuccessfully treated cases, a contralateral dysplasia developed, and in one untreated, subluxation. The authors are advocating a systematic and early detection and treatment of the primary coxa obliqua. .

  17. Inequalities in use of total hip arthroplasty for hip fracture: population based study

    Science.gov (United States)

    Metcalfe, David; Griffin, Xavier L; Costa, Matthew L

    2016-01-01

    Objectives To determine whether the use of total hip arthroplasty (THA) among individuals with a displaced intracapsular fracture of the femoral neck is based on national guidelines or if there are systematic inequalities. Design Observational cohort study using the National Hip Fracture Database (NHFD). Setting All hospitals that treat adults with hip fractures in England, Wales, and Northern Ireland. Participants Patients within the national database (all aged ≥60) who received operative treatment for a non-pathological displaced intracapsular hip fracture from 1 July 2011 to 31 April 2015. Main outcome measures Provision of THA to patients considered eligible under criteria published by the National Institute for Health and Care Excellence (NICE). Results 114 119 patients with hip fracture were included, 11 683 (10.2%) of whom underwent THA. Of those who satisfied the NICE criteria, 32% (6780)received a THA. Of patients who underwent THA, 42% (4903) did not satisfy the NICE criteria. A recursive partitioning algorithm found that the NICE eligibility criteria did not optimally explain which patients underwent THA. A model with superior explanatory power drew distinctions that are not supported by NICE, which were an age cut off at 76 and a different ambulation cut off. Among patients who satisfied the NICE eligibility, the use of THA was less likely with higher age (odds ratio 0.88, 95% confidence interval 0.87 to 0.88), worsening abbreviated mental test scores (0.49 (0.41 to 0.58) for normal cognition v borderline cognitive impairment)), worsening American Society of Anesthesiologists score (0.74, 0.66 to 0.84), male sex (0.85, 0.77 to 0.93), worsening ambulatory status (0.32, 0.28 to 0.35 for walking with a stick v independent ambulation), and fifths of worsening socioeconomic area deprivation (0.76 (0.66 to 0.88) for least v most deprived fifth). Patients receiving treatment during the working week were more likely to receive THA than at the

  18. Artificial sweeteners - a review.

    Science.gov (United States)

    Chattopadhyay, Sanchari; Raychaudhuri, Utpal; Chakraborty, Runu

    2014-04-01

    Now a days sugar free food are very much popular because of their less calorie content. So food industry uses various artificial sweeteners which are low in calorie content instead of high calorie sugar. U.S. Food and Drug Administration has approved aspartame, acesulfame-k, neotame, cyclamate and alitame for use as per acceptable daily intake (ADI) value. But till date, breakdown products of these sweeteners have controversial health and metabolic effects. On the other hand, rare sugars are monosaccharides and have no known health effects because it does not metabolize in our body, but shows same sweet taste and bulk property as sugar. Rare sugars have no such ADI value and are mainly produced by using bioreactor and so inspite of high demand, rare sugars cannot be produced in the desired quantities. PMID:24741154

  19. Artificial Immune Systems (2010)

    CERN Document Server

    Greensmith, Julie; Aickelin, Uwe

    2010-01-01

    The human immune system has numerous properties that make it ripe for exploitation in the computational domain, such as robustness and fault tolerance, and many different algorithms, collectively termed Artificial Immune Systems (AIS), have been inspired by it. Two generations of AIS are currently in use, with the first generation relying on simplified immune models and the second generation utilising interdisciplinary collaboration to develop a deeper understanding of the immune system and hence produce more complex models. Both generations of algorithms have been successfully applied to a variety of problems, including anomaly detection, pattern recognition, optimisation and robotics. In this chapter an overview of AIS is presented, its evolution is discussed, and it is shown that the diversification of the field is linked to the diversity of the immune system itself, leading to a number of algorithms as opposed to one archetypal system. Two case studies are also presented to help provide insight into the m...

  20. Return to Play Following Hip Arthroscopy.

    Science.gov (United States)

    Lee, Simon; Kuhn, Andrew; Draovitch, Pete; Bedi, Asheesh

    2016-10-01

    Femoroacetabular impingement may be particularly disabling to the high-demand athlete, especially those with significant cutting and pivoting requirements. If nonoperative treatment fails to adequately alleviate symptoms or sufficiently restore function in the athlete, hip arthroscopy can lead to improved pain, improved range of motion, and high rates of return to play with proper postoperative rehabilitation. The rate of return to previous level of competition is also high with accurate diagnosis and well-executed correction of deformity. A clear understanding of the etiology, diagnosis, management, and outcomes is essential for clinicians to optimally help patients to return to play. PMID:27543404

  1. Hip Instability: Current Concepts and Treatment Options.

    Science.gov (United States)

    Dumont, Guillaume D

    2016-07-01

    Instability of the hip can manifest in a wide range of settings, with presenting symptoms including subtle discomfort at end range of motion or more dramatic dislocation of the joint. It can result from traumatic injury with dislocation or subluxation; atraumatic capsular laxity; structural bony abnormality, such as acetabular dysplasia; and iatrogenic injury. Initial treatment of the concentrically reduced joint often begins with physical therapy to strengthen dynamic stabilizers and to allow time for resolution of acute symptoms. Surgical treatment is aimed at repairing injured soft tissue structures, including static stabilizers, and addressing underlying bony structural deficiencies. PMID:27343395

  2. Hip labral cyst caused by psoas impingement.

    Science.gov (United States)

    Tey, Marc; Alvarez, Sonia; Ríos, Jose L

    2012-08-01

    Hip labral impingement can cause labral tears and secondary paralabral cyst formation. Femoroacetabular impingement is the main cause of labral impingement, but other conditions such as iliopsoas tendon impingement are described. There is no description of labral cyst resulting from psoas impingement treated arthroscopically in the literature. We present the case of a young sportsman with groin pain caused by psoas impingement with a labral tear and secondary paralabral cyst who was treated arthroscopically by cyst debridement, psoas tenotomy, and labral repair. PMID:22840990

  3. Pemberton technique in congenital hip dislocation

    OpenAIRE

    Cakmak, Mehmet; Cabuk, Mustafa K.; Karamehmetoglu, Mahmut; Taser, Omer; Domanic, Unsal; Hamzaoglu, Azmi

    2004-01-01

    63 hips of 55 cases on when Pemberton osteotomy was performed because of acetabular dysplasia have been examined at the termination of a period of at least 6 months and at most 26 months, with an average of 8 months of following in the Department of Orthopaedics and Traumatology of the Istanbul Medical School. It has been concluded that with Pemberton osteotomy the acetabular index which was found to be 39.5 prior to surgery was reduced to 20.3, and that in 82.5% of cases good results in 12.6...

  4. Segmental blood pressure after total hip replacement

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Soelberg, M; Henriksen, Jens Henrik Sahl

    1992-01-01

    Twenty-nine patients due to have a total hip replacement had their systemic systolic and segmental blood pressures measured prior to operation and 1 and 6 weeks postoperatively. No patients had signs of ischemia. The segmental blood pressure was measured at the ankle and at the toes. A significant...... drop was found in all pressures 1 week postoperatively. The decrease followed the systemic pressure and was restored to normal after 6 weeks. In a group of six patients with preoperatively decreased ankle pressure, a significant transient further decrease in the ankle-toe gradient pressure was found...

  5. A Third Giant Planet Orbiting HIP 14810

    OpenAIRE

    Wright, J. T.; Fischer, D. A.; Ford, Eric B.; Veras, D.; Wang, J.; Henry, G. W.; Marcy, G. W.; Howard, A. W.; Johnson, John Asher

    2009-01-01

    We present new precision radial velocities and a three-planet Keplerian orbit fit for the V = 8.5, G5 V star HIP 14810. We began observing this star at Keck Observatory as part of the N2K Planet Search Project. Wright et al. announced the inner two planets to this system, and subsequent observations have revealed the outer planet and the proper orbital solution for the middle planet. The planets have minimum masses of 3.9, 1.3, and 0.6 M_(Jup) and orbital periods of 6.67, 147.7, and 952 day, ...

  6. A Third Planet Orbiting HIP 14810

    OpenAIRE

    Wright, Jason T.; Fischer, Debra A; Ford, Eric B.; Veras, Dimitri; Wang, Ji; Henry, Gregory W.; Marcy, Geoff W.; Howard, Andrew W.; Johnson, John Asher

    2009-01-01

    We present new precision radial velocities and a three-planet Keplerian orbit fit for the V = 8.5, G5 V star HIP 14810. We began observing this star at Keck Observatory as part of the N2K Planet Search Project. Wright et al. (2007) announced the inner two planets to this system, and subsequent observations have revealed the outer planet planet and the proper orbital solution for the middle planet. The planets have minimum masses of 3.9, 1.3, and 0.6 M_Jup and orbital periods of 6.67, 147.7, a...

  7. Hip and knee arthroplasty: quo vadis?

    OpenAIRE

    Ho, J; Meis, J. F. G. M.; Nabuurs-Franssen, M.H.; Voss, A.

    2015-01-01

    Despite of the steady decrease of surgical site infection (SSI) over the last two decades, the incidence of SSI after hip and knee arthroplasty has recently surged. This may be explained by technical changes that may result in an increased risk of SSI, such as the broad implementation of fast track programs, and/or early interventions on suspected SSI. By definition, early intervention may lead to a higher SSI score, even in the absence of a true SSI. In any case, the reverse trend of SSI war...

  8. A Primer on Artificial Intelligence.

    Science.gov (United States)

    Leal, Ralph A.

    A survey of literature on recent advances in the field of artificial intelligence provides a comprehensive introduction to this field for the non-technical reader. Important areas covered are: (1) definitions, (2) the brain and thinking, (3) heuristic search, and (4) programing languages used in the research of artificial intelligence. Some…

  9. Generalized Adaptive Artificial Neural Networks

    Science.gov (United States)

    Tawel, Raoul

    1993-01-01

    Mathematical model of supervised learning by artificial neural network provides for simultaneous adjustments of both temperatures of neurons and synaptic weights, and includes feedback as well as feedforward synaptic connections. Extension of mathematical model described in "Adaptive Neurons For Artificial Neural Networks" (NPO-17803). Dynamics of neural network represented in new model by less-restrictive continuous formalism.

  10. Sucrose compared with artificial sweeteners

    DEFF Research Database (Denmark)

    Sørensen, Lone Brinkmann; Vasilaras, Tatjana H; Astrup, Arne;

    2014-01-01

    There is a lack of appetite studies in free-living subjects supplying the habitual diet with either sucrose or artificially sweetened beverages and foods. Furthermore, the focus of artificial sweeteners has only been on the energy intake (EI) side of the energy-balance equation. The data are from a...

  11. A novel DXA-based hip failure index captures hip fragility independent of BMD.

    Science.gov (United States)

    Sievänen, H; Weynand, L S; Wacker, W K; Simonelli, C; Burke, P K; Ragi, S; Del Rio, L

    2008-01-01

    Capability of a novel dual-energy X-ray absorptiometry (DXA)-based hip failure index (HiFI) to discriminate between hip fracture cases and controls was evaluated. Given the constraints of planar DXA, the femoral neck was assumed a foam-filled ( approximately trabecular bone), thin-walled ( approximately cortical bone) sandwich structure, while HiFI estimated the critical force sufficient to buckle the wall of such a structure. Proximal femur DXA data from 1379 women aged 65yr and older, 268 with prior hip fracture were used. Comparison between standard areal bone mineral density (BMD), femur strength index (FSI), and HiFI was based on areas under receiver operatoring characteristic curves (AUC). The mean femoral neck BMD (SD) was 0.689 (0.109) g/cm(2) among the cases and 0.768 (0.119) g/cm(2) among the controls; the mean FSI 1.33 (0.36) and 1.54 (0.41), and the mean HiFI -0.28 (0.14) and -0.18 (0.15), respectively; all intergroup differences were highly significant (pHiFI remained significant (pHiFI. In conclusion, HiFI may capture structural traits that account for femoral neck fragility independently of BMD or FSI. Obviously, the use of actual geometric and structural information from three-dimensional imaging of the femoral neck would help diminish the crude assumptions of the present DXA approach and reveal the true potential of the HiFI approach to gauge hip fragility and identify at-risk individuals for hip fractures. PMID:18456529

  12. Hybrid SPECT/CT for the assessment of a painful hip after uncemented total hip arthroplasty

    International Nuclear Information System (INIS)

    The diagnosis of hip pain after total hip replacement (THR) represents a highly challenging question that is of increasing concern to orthopedic surgeons. This retrospective study assesses bone scintigraphy with Hybrid SPECT/CT for the diagnosis of painful THR in a selected cohort of patients. Bone SPECT/CT datasets of 23 patients (mean age 68.9 years) with a painful hip after THR were evaluated. Selection of the patients required an inconclusive radiograph, normal serum levels of inflammatory parameters (CRP and ESR) or a negative aspiration of the hip joint prior to the examination. The standard of reference was established by an interdisciplinary adjudication-panel using all imaging data and clinical follow-up data (>12 month). Pathological and physiological uptake patterns were defined and applied. The cause of pain in this study group could be determined in 18 out of 23 cases. Reasons were aseptic loosening (n = 5), spine-related (n = 5), heterotopic ossification (n = 5), neuronal (n = 1), septic loosening (n = 1) and periprosthetic stress fracture (n = 1). In (n = 5) cases the cause of hip pain could not be identified. SPECT/CT imaging correctly identified the cause of pain in (n = 13) cases, in which the integrated CT-information led to the correct diagnosis in (n = 4) cases, mainly through superior anatomic correlation. Loosening was correctly assessed in all cases with a definite diagnosis. SPECT/CT of THA reliably detects or rules out loosening and provides valuable information about heterotopic ossifications. Furthermore differential diagnoses may be detected with a whole-body scan and mechanical or osseous failure is covered by CT-imaging. SPECT/CT holds great potential for imaging-based assessment of painful prostheses

  13. Total hip arthroplasty with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis

    Institute of Scientific and Technical Information of China (English)

    吴立东; 金礼斌; 严世贵; 杨泉森; 戴雪松; 王祥华

    2004-01-01

    Objective:To evaluate the outcome of total hip arthroplasty (THA) with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis.Methods: Between 1995 and 2002, we implanted 23cementless cups and femoral head autografts in 20 patients with hip dysplasia and osteoarthritis. In this study, a retrospective study was made on 21 hips in 20 patients (18females and 2 males, aged 50 years on an average) with developmental hip dysplasia treated by THA with acementless cup and femoral head autograft. The acetabular cup was placed at the level of the true acetabuinm and all the patients required autogenous femoral head grafts due to acetabular deficiency. The average rate of the acetabular cup covered by the femoral head autograft was 31%(ranging from 10% to 45%). Eight hips had less than 25%cup coverage and thirteen between 25% and 50%. The average follow-up period was 4.7 years (range, 1-8 years).The replacing outcome was evaluated by modified Harris hip score. Preoperative and follow-up radiographs were made.Results: All the autografts were united to the host bones. No autograft was collapsed or no component from the hip was loosed in all the patients. According to the modified Harris hip score, the average hip score increased from 46 before operation to 89 at the final review. Before operation, the leg-length discrepancy was greater than 2 cm in all the patients except one with bilateral hip dysplasia.After operation, only 2 out of 20 patients had a leg-length discrepancy greater than 1 cm. Three hips showed minor bone resorption in the lateral portion of the graft, which did not support the cup. Three hips developed Grade 1Brooker heterotopic ossification and one developed Grade 2.Conclusions: THA with a cementless cup and a femoral head autograft for patients with osteoarthritis resulted from hip dysplasia can result in favorable outcomes. This method can provide reliable acetabular fixation and restore the acetabular bone stock in

  14. Development of HIP bonding procedure and mechanical properties of HIP bonded joints for reduced activation ferritic steel F-82H

    International Nuclear Information System (INIS)

    Structural materials of blanket components in fusion DEMO reactors will receive a neutron wall load more than 3-5MW/m2 as well as exposed by surface heat flux more than 0.5MW/m2. A reduced activation ferritic steel F-82H has been developed by JAERI in collaboration with NKK from viewpoints of resistance for high temperature and neutron loads and lower radioactivity. This study intends to obtain basic performance of F-82H to establish the fabrication procedure of the first wall and blanket box by using Hot Isostatic Pressing (HIP) bonding. Before HIP bonding tests, effects of heat treatment temperature and surface roughness on mechanical properties of joints were investigated in the heat treatment tests and diffusion bonding tests, respectively. From these results, the optimum HIP bonding conditions and the post heat treatment were selected. Using these conditions, the HIP bonding tests were carried out to evaluate HIP bondability and to obtain mechanical properties of the joints. Sufficient HIP bonding performance was obtained under the temperature of 1040degC, the compressive stress of 150MPa, the holding time of 2h, and the surface roughness ∼μ m. Mechanical properties of HIP bonded joints with these conditions were similar to those of as-received base metal. An oxide formation on the surface to be bonded would need to be avoided for sufficient bonding. The bonding ratio, Charpy impact value and fatigue performance of the joints strongly depended on the HIP conditions, especially temperature, while micro-structure, Vickers hardness and tensile properties had little dependence on the HIP temperature. The surface roughness strongly affected the bonding ratio and would be required to be in the level of a few μ m. In the HIP bonding test of the welded material, the once-melted surface could be jointed by the HIP bonding under the above-mentioned procedure. (J.P.N.)

  15. Artificial (Pu 90Sr, 241Am) and natural (U) isotopes in human bones from Poland

    International Nuclear Information System (INIS)

    In two papers we have presented results if analyses of artificial isotopes (238,239,240Pu, 241Am and 90Sr) content in human bones, using samples collected during hip joint replacement surgery. Since the patients were members of general population (not exposed in any particular form to artificial radionuclides) results can be treated as current background level for Poland and perhaps also whole central Europe. During this project the open question appeared - what is the level in human bones of natural alpha emitters like 238U-, 234U, for instance. Therefore about 30 human hip joint bone samples are being now analysed for the presence of uranium along with mentioned above artificial radionuclides. Samples are ashen and sequential radiochemical analyse is applied for separation of Pu, Sr and Am isotopes followed by separation of uranium using anion exchange resin. Measurements of plutonium, americium and uranium are performed using alpha spectrometry. That for 90Sr is done by LSC. Results will be presented during conference. Document available in abstract form only. (authors)

  16. Hip-Hop, the "Obama Effect," and Urban Science Education

    Science.gov (United States)

    Emdin, Christopher; Lee, Okhee

    2012-01-01

    Background/Context: With the ever increasing diversity of schools, and the persistent need to develop teaching strategies for the students who attend today's urban schools, hip-hop culture has been proposed to be a means through which urban youth can find success in school. As a result, studies of the role of hip-hop in urban education have grown…

  17. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... that’s hip resurfacing; let’s look at the PowerPoint one more time, just for a few more slides, talking about some of the clinical issues. And again, the results of hip resurfacing have been evaluated across the world, and many places are keeping lots of data. ...

  18. One step HIP canning of powder metallurgy composites

    Science.gov (United States)

    Juhas, John J. (Inventor)

    1990-01-01

    A single step is relied on in the canning process for hot isostatic pressing (HIP) powder metallurgy composites. The binders are totally removed while the HIP can of compatible refractory metal is sealed at high vacuum and temperature. This eliminates outgassing during hot isostatic pressing.

  19. Extreme Kinematics in Selected Hip Hop Dance Sequences.

    Science.gov (United States)

    Bronner, Shaw; Ojofeitimi, Sheyi; Woo, Helen

    2015-09-01

    Hip hop dance has many styles including breakdance (breaking), house, popping and locking, funk, streetdance, krumping, Memphis jookin', and voguing. These movements combine the complexity of dance choreography with the challenges of gymnastics and acrobatic movements. Despite high injury rates in hip hop dance, particularly in breakdance, to date there are no published biomechanical studies in this population. The purpose of this study was to compare representative hip hop steps found in breakdance (toprock and breaking) and house and provide descriptive statistics of the angular displacements that occurred in these sequences. Six expert female hip hop dancers performed three choreographed dance sequences, top rock, breaking, and house, to standardized music-based tempos. Hip, knee, and ankle kinematics were collected during sequences that were 18 to 30 sec long. Hip, knee, and ankle three-dimensional peak joint angles were compared in repeated measures ANOVAs with post hoc tests where appropriate (p<0.01). Peak angles of the breaking sequence, which included floorwork, exceeded the other two sequences in the majority of planes and joints. Hip hop maximal joint angles exceeded reported activities of daily living and high injury sports such as gymnastics. Hip hop dancers work at weight-bearing joint end ranges where muscles are at a functional disadvantage. These results may explain why lower extremity injury rates are high in this population. PMID:26395613

  20. Clinical recovery of two hip adductor longus ruptures

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Petersen, Jesper; Nielsen, Michael Bachmann;

    2013-01-01

    was evaluated using hip-strength assessments, self-report and ultrasonography until complete muscle-strength recovery of the hip adductors had occurred. The player was able to participate in a full soccer training session without experiencing pain 15 weeks after the first rupture, and 12 weeks after...

  1. Hip dysplasia in a 6-year-old Salz ram

    OpenAIRE

    Loste, Araceli; Ramos, Juan José; Sáez, Teófilo; Sever, Ramón; Marca, Carmen

    2003-01-01

    A 6-year old Salz ram was presented with a history of poor body condition, progressive gait abnormalities, pelvic limb lameness, and difficulty with copulation. Based on the history, clinical signs, hip palpation, and radiography, a diagnosis of hip dysplasia, previously unreported in sheep, was made.

  2. Normative values of eccentric hip abduction strength in novice runners

    DEFF Research Database (Denmark)

    Jørgensen, Daniel Ramskov; Pedersen, Mette Broen; Kastrup, Kristrian; Lønbro, Simon; Jacobsen, J S; Thorborg, K; Nielsen, R O; Rasmussen, S

    2014-01-01

    PURPOSE: Low eccentric strength of the hip abductors, might increase the risk of patellofemoral pain syndrome and iliotibial band syndrome in runners. No normative values for maximal eccentric hip abduction strength have been established. Therefore the purpose of this study was to establish norma...

  3. Hip Hop Is Now: An Evolving Youth Culture

    Science.gov (United States)

    Taylor, Carl; Taylor, Virgil

    2007-01-01

    Emerging from Rap music, Hip Hop has become a lifestyle to many modern youth around the world. Embodying both creativity and controversy, Hip Hop mirrors the values, violence, and hypocrisy of modern culture. The authors dispel some of the simplistic views that surround this evolving youth movement embraced by millions of young people who are…

  4. Chicano Hip-Hop as Interethnic Contact Zone

    Science.gov (United States)

    McFarland, Pancho

    2008-01-01

    The critical study of rap music and hip-hop culture has the potential to expand Americans understanding of race and culture in the United States. Hip-hop culture as a multiracial, multiethnic phenomenon reveals the ways in which race relations over the past thirty years have become increasingly complex. The theories and concepts that they use to…

  5. Hip arthroplasty for failed treatment of proximal femoral fractures.

    Science.gov (United States)

    D'Arrigo, Carmelo; Perugia, Dario; Carcangiu, Alessandro; Monaco, Edoardo; Speranza, Attilio; Ferretti, Andrea

    2010-10-01

    Failed treatment of an intertrochanteric fracture typically leads to profound functional disability and pain. Salvage treatment with hip arthroplasty may be considered. The aim of this study was to evaluate the results and complications of hip arthroplasty performed as a salvage procedure after the failed treatment of an intertrochanteric hip fracture. Twenty-one patients were treated in our hospital with hip arthroplasty for failed treatment of intertrochanteric hip fracture. There were sixteen women and five men with a mean age of 75.8 years (range 61-85 years). Fourteen patients had failure of a previous nail fixation procedure, five had failure of a plate fixation, one of hip screws fixation and one of Ender nail fixation. In 19 out of 21 patients we performed a total hip arthroplasty-14 cases used modular implants with long-stems and five cases used a standard straight stem. In 2 of 21 cases we used a bipolar hemiarthroplasty. A statistically significant improvement was found comparing pre and postoperative conditions (p < 0.05). Our experience confirms that total hip arthroplasty is a satisfactory salvage procedure after failed treatment of an intertrochanteric fracture in elderly patients with few serious orthopaedic complications and acceptable clinical outcomes. PMID:19572131

  6. HIP ROTATIONAL VELOCITIES DURING THE FULL GOLF SWING

    Directory of Open Access Journals (Sweden)

    Heather Gulgin

    2009-06-01

    Full Text Available Since labral pathology in professional golfers has been reported, and such pathology has been associated with internal/external hip rotation, quantifying the rotational velocity of the hips during the golf swing may be helpful in understanding the mechanism involved in labral injury. Thus, the purpose of this study was to determine the peak internal/external rotational velocities of the thigh relative to the pelvis during the golf swing. Fifteen female, collegiate golfers participated in the study. Data were acquired through high-speed three dimensional (3-D videography using a multi-segment bilateral marker set to define the segments, while the subjects completed multiple repetitions of a drive. The results indicated that the lead hip peak internal rotational velocity was significantly greater than that of the trail hip external rotational velocity (p = 0.003. It appears that the lead hip of a golfer experiences much higher rotational velocities during the downswing than that of the trail hip. In other structures, such as the shoulder, an increased risk of soft tissue injury has been associated with high levels of rotational velocity. This may indicate that, in golfers, the lead hip may be more susceptible to injury such as labral tears than that of the trailing hip

  7. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... can be done but should not be the only focus of the operation. So perhaps at this point -- I think the next step is to talk about another type of surgery that we perform at Thomas Jefferson University Hospital. It’s called hip resurfacing hip replacement and ...

  8. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... hip joint; that’s the acetabular bone you’re looking at. Again, up is the front of the ... a significantly larger incision. So if you’re looking for a small- incision hip replacement, the last ...

  9. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... hip replacement? And is the degree -- is the type and the degree of activities I do different if I had a traditional hip replacement versus resurfacing. Dr. Austin, do you want to take that question first? And then we’ll ask Dr. Hozack ...

  10. Hip Hop as Empowerment: Voices in El Alto, Bolivia

    Science.gov (United States)

    Tarifa, Ariana

    2012-01-01

    In response to neoliberal policies that have been in place since 1985, Bolivian young people have increasingly used hip hop music as a means of protest and to reclaim social and political participation. Hip hop in Latin America tells the story of the struggles that marginalized people have suffered, and speaks to the effects of international…

  11. Strain-stress analysis of pathological hip joint after osteotomy

    Czech Academy of Sciences Publication Activity Database

    Návrat, Tomáš; Florian, Z.; Vosynek, P.

    Prague : Czech Society of Biomechanics Charles Univerzity in Prague, 2008, s. 1-2. ISBN 978-80-01-04163-5. [Human Biomechanics 2008. Praha (CZ), 29.09.2008-01.10.2008] Institutional research plan: CEZ:AV0Z20760514 Keywords : biomechanics of human voice * healthy hip joint * pathological hip joint Subject RIV: BO - Biophysics

  12. Imaging of sports-related hip and groin injuries.

    Science.gov (United States)

    Lischuk, Andrew W; Dorantes, Thomas M; Wong, William; Haims, Andrew H

    2010-05-01

    A normally functioning hip joint is imperative for athletes who use their lower extremities with running, jumping, or kicking activities. Sports-related injuries of the hip and groin are far less frequent than injuries to the more distal aspect of the extremity, accounting for less than 10% of lower extremity injuries. Despite the lower incidence, hip and groin injuries can lead to significant clinical and diagnostic challenges related to the complex anatomy and biomechanical considerations of this region. Loads up to 8 times normal body weight have been documented in the joint in common daily activities, such as jogging, with significantly greater force expected during competitive athletics. Additionally, treatment for hip and groin injuries can obviate the participation of medical and surgical specialties, with a multidisciplinary approach frequently required. Delay in diagnosis and triage of these injuries may cause loss of time from competition and, potentially, early onset of degenerative changes. Magnetic resonance imaging (MRI) of the hip has proven to be the gold standard for the diagnosis of sports-related hip and groin injuries in the setting of negative radiographs. With its exquisite soft tissue contrast, multiplanar capabilities, and lack of ionizing radiation, MRI is unmatched in the noninvasive diagnosis of intra-articular and extra-articular pathology, as well as intraosseous processes. This review focuses on MRI of common athletic injuries of the hip and groin, including acetabular labral tears, femoral acetabular impingement syndrome, muscle injuries around the hip and groin (including athletic pubalgia), and athletic osseous injuries. PMID:23015946

  13. Feasibility of progressive strength training shortly after hip fracture surgery

    DEFF Research Database (Denmark)

    Overgaard, Jan; Kristensen, Morten T

    2013-01-01

    To investigate the feasibility of a 6-wk progressive strength-training programme commenced shortly after hip fracture surgery in community-dwelling patients.......To investigate the feasibility of a 6-wk progressive strength-training programme commenced shortly after hip fracture surgery in community-dwelling patients....

  14. Toward Hip-Hop Pedagogies for Music Education

    Science.gov (United States)

    Kruse, Adam J.

    2016-01-01

    Music education scholarship in the areas of popular, vernacular, and participatory musicianship has grown in the past decades; however, music education research concerned specifically with hip-hop has been relatively scarce. Because hip-hop music can differ tremendously from the traditional western genres with which many music educators are most…

  15. Paralytic dislocations of the hip in adolescence: Orthopaedic treatment

    Directory of Open Access Journals (Sweden)

    Čobeljić Goran

    2009-01-01

    Full Text Available Paralytic dislocation of the hip in adolescence is not typical, but presents a serious problem whether diagnosed primarily in adolescence or due to the lack of treatment or failed treatment in earlier age. It is characteristic of cerebral palsy and myelomeningocele. If the paralytic dislocation of the hip in adolescence is asymmetric, then pelvic obliquity, leg-length discrepancy, imbalance in sitting position, scoliosis and secondary spondylosis with all its consequences ensue. Complications like hip pains due to secondary arthrosis and walking ability impairment are frequent in ambulatory patients. The dislocation is the result of muscle imbalances in the hip region. The diagnosis is based on Illness history, clinical examination, neurological examination and radiography. Treatment is mostly operative, except in cases of pelvic symmetry and absence of difficulties. Pelvic and/or femoral osteotomy with or without open reduction of the hip is done in ambulatory patients with cerebral palsy. Soft-tissue surgery, hip flexors release and tenotomy of the hip adductors, are done in non-ambulatory patients with cerebral palsy. In patients with myelomeningocele soft-tissue surgery, hip flexors release and tractus iliotibialis resection on the lower side of the pelvis, are done regardless of the ability to walk. The same bone surgery procedures as in cerebral palsy are done only in ambulatory patients with unilateral dislocations if soft-tissue surgery failed.

  16. State-of-the-Art Hip Surgeries for Active Adults

    Medline Plus

    Full Text Available ... going to cover today hip surgery for active adults, and perhaps the best thing to do at this point would be to ... art surgical options for young and active older adults with hip disease from ... Internet broadcast represents the hospital’s ongoing efforts to bring ...

  17. Christian Hip Hop as Pedagogy: A South African Case Study

    Science.gov (United States)

    Abraham, Ibrahim

    2015-01-01

    Drawing on interviews with creators of Christian hip hop music in South Africa, this article demonstrates that this genre of popular music and youth culture is utilised as a form of pedagogy to transmit religious beliefs and values to contemporary youth. The pedagogical aspects of hip hop have been recognised in research on the topic, but the…

  18. Prevalence of hip osteoarthritis in chiropractic practice in denmark

    DEFF Research Database (Denmark)

    Poulsen, Erik; Christensen, Henrik W; Overgaard, Søren; Hartvigsen, Jan

    2012-01-01

    The purposes of this study were to measure the prevalence of clinical and radiographic hip osteoarthritis (OA) and first-time diagnosis of hip OA in consecutive patients presenting to chiropractic practices in Denmark and to report the components of the initial treatment rendered by the...

  19. Soft computing in artificial intelligence

    CERN Document Server

    Matson, Eric

    2014-01-01

    This book explores the concept of artificial intelligence based on knowledge-based algorithms. Given the current hardware and software technologies and artificial intelligence theories, we can think of how efficient to provide a solution, how best to implement a model and how successful to achieve it. This edition provides readers with the most recent progress and novel solutions in artificial intelligence. This book aims at presenting the research results and solutions of applications in relevance with artificial intelligence technologies. We propose to researchers and practitioners some methods to advance the intelligent systems and apply artificial intelligence to specific or general purpose. This book consists of 13 contributions that feature fuzzy (r, s)-minimal pre- and β-open sets, handling big coocurrence matrices, Xie-Beni-type fuzzy cluster validation, fuzzy c-regression models, combination of genetic algorithm and ant colony optimization, building expert system, fuzzy logic and neural network, ind...

  20. Beyond AI: Artificial Dreams Conference

    CERN Document Server

    Zackova, Eva; Kelemen, Jozef; Beyond Artificial Intelligence : The Disappearing Human-Machine Divide

    2015-01-01

    This book is an edited collection of chapters based on the papers presented at the conference “Beyond AI: Artificial Dreams” held in Pilsen in November 2012. The aim of the conference was to question deep-rooted ideas of artificial intelligence and cast critical reflection on methods standing at its foundations.  Artificial Dreams epitomize our controversial quest for non-biological intelligence, and therefore the contributors of this book tried to fully exploit such a controversy in their respective chapters, which resulted in an interdisciplinary dialogue between experts from engineering, natural sciences and humanities.   While pursuing the Artificial Dreams, it has become clear that it is still more and more difficult to draw a clear divide between human and machine. And therefore this book tries to portrait such an image of what lies beyond artificial intelligence: we can see the disappearing human-machine divide, a very important phenomenon of nowadays technological society, the phenomenon which i...

  1. Structural integrity evaluation for HIP bonded fusion DEMO reactor component

    International Nuclear Information System (INIS)

    HIP (Hot Isostatic Pressing) is applicable to fabrication technology for in-vessel components of fusion DEMO reactor, which has been fabricated by ferritic steel F82H. Verification of structural integrity of HIP bonded joint is one of the most important subjects on the development of fusion DEMO reactor component. Even now structural integrity evaluation method for HIP bonded joint is not enough estimated. This paper describes the results of low cycle fatigue test and inelastic analysis using HIP-element model under the bending load of fusion DEMO reactor. Low cycle fatigue strength and fracture/deformation mode has been obtained. SEM-observation was performed at the fracture surface of HIP-element model and the bonded joints between cooling tubes and plate were inspected. (author)

  2. Influence of anaesthesia on canine hip dysplasia score.

    Science.gov (United States)

    Genevois, J-P; Chanoit, G; Carozzo, C; Remy, D; Fau, D; Viguier, E

    2006-10-01

    Hip dysplasia (HD) scores, based on the five grades, as defined by the Fédération Cynologique Internationale, were compared between anaesthetized (group 1, n = 3839) and non-sedated non-anaesthetized dogs (group 2, n = 1517). Each dog was radiographed in the standard ventro-dorsal hip joint extended position. Each radiograph was evaluated by the same reader blinded regarding the dog's status of anaesthesia. Results showed that there was a significant difference in hip dysplasia prevalence between group 1 (22%) compared with group 2 (9%) (P < 0.005). This difference was the result of a lower rate of hip-joint laxity assessment and the measurement of Norberg-Olsson angle <105 degrees in group 2 compared with group 1. The acetabular and femoral morphologies were not significantly different between the groups. The data confirm that the scoring of dogs for HD on standard radiographs with the hip joints extended is influenced by anaesthesia. PMID:16970631

  3. Copenhagen hip and groin outcome score (HAGOS) in male soccer

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Branci, Sonia; Stensbirk, Frederik;

    2014-01-01

    BACKGROUND/AIM: Reference values are needed in order to interpret the Copenhagen Hip and Groin Outcome Score (HAGOS) in male soccer players with hip and groin pain. The aim of this study was to establish reference values for HAGOS in hip and groin injury-free male soccer players. METHODS: We...... included 444 groin injury-free soccer players from 40 clubs (divisions 1-4) in Eastern Denmark, mean age (SD) 23.6 (4.4), training soccer 3.4 (1) times per week. All players were hip and groin injury-free at the time of inclusion (beginning of season, 2011). RESULTS: Of the 444 hip and groin injury...... HAGOS subscales (psoccer players, with no pain in the previous or present season (n=301), are: pain: 80.1-100, symptoms: 64.3-100, activities of daily living: 80...

  4. Imaging of the hip and bony pelvis. Techniques and applications

    Energy Technology Data Exchange (ETDEWEB)

    Davies, A.M. [Royal Orthopaedic Hospital, Birmingham (United Kingdom). MRI Centre; Johnson, K.J. [Princess of Wales Birmingham Children' s Hospital (United Kingdom); Whitehouse, R.W. (eds.) [Manchester Royal Infirmary (United Kingdom). Dept. of Clinical Radiology

    2006-07-01

    This is a comprehensive textbook on imaging of the bony pelvis and hip joint that provides a detailed description of the techniques and imaging findings relevant to this complex anatomical region. In the first part of the book, the various techniques and procedures employed for imaging the pelvis and hip are discussed in detail. The second part of the book documents the application of these techniques to the diverse clinical problems and diseases encountered. Among the many topics addressed are congenital and developmental disorders including developmental dysplasia of the hip, irritable hip and septic arthritis, Perthes' disease and avascular necrosis, slipped upper femoral epiphysis, bony and soft tissue trauma, arthritis, tumours and hip prostheses. Each chapter is written by an acknowledged expert in the field, and a wealth of illustrative material is included. This book will be of great value to musculoskeletal and general radiologists, orthopaedic surgeons and rheumatologists. (orig.)

  5. The innervation of canine hip joint capsule: an anatomic study.

    Science.gov (United States)

    Huang, C H; Hou, S M; Yeh, L S

    2013-12-01

    To clarify the contributions of the nerves supplying the canine hip joint capsule for clinical application, cadaver study of six healthy mongrel dogs was performed. The pelvises and hindlimbs of cadavers were dissected and fixed in formaldehyde. Innervation of the joint capsule was investigated with the aid of an operative microscope. As a result, the canine hip joint capsule receives multiple innervations from articular branches of four nerves. They are articular nerve fibres of femoral, obturator, cranial gluteal and sciatic nerves from the cranioventral, caudoventral, craniolateral and dorsolateral directions of the joint, respectively. No branch originating from the caudal gluteal nerve was observed innervating the hip joint capsule. Our data provides useful information for research on the canine hip joint, including pain analysis with hip disorders and surgical nerve blockade to relieve pain. PMID:23410229

  6. Current Challenges in Pain Management in Hip Fracture Patients.

    Science.gov (United States)

    Sanzone, Anthony G

    2016-05-01

    The high incidence of hip fracture, together with considerable associated morbidity, mortality, and cost of care, makes this injury a major clinical challenge. Of particular importance is the pain associated with hip fracture, which can have potentially severe consequences and may lead to delayed recovery. The prevailing opioid-dependent model of analgesia, however, presents multiple drawbacks and risks that can compromise outcomes in the hip fracture population. The pain management process has essential preoperative, intraoperative, and postoperative components, yet data on the comparative effectiveness of different pain management interventions in patients undergoing surgery for hip fracture are not clear cut. A Cochrane database review that included 83 different pain management studies indicated that there are not enough well-designed studies to show unequivocally which pain management approaches work well after hip fracture surgery. Yet a growing body of data on certain interventions, such as nerve blocks and multimodal analgesia, supports consideration of these options. PMID:27101319

  7. Bernese periacetabular osteotomy for hip dysplasia: Surgical technique and indications.

    Science.gov (United States)

    Kamath, Atul F

    2016-05-18

    For young, active patients with healthy hip cartilage, pelvic osteotomy is a surgical option in to address hip pain and to improve mechanical loading conditions related to dysplasia. Hip dysplasia may lead to arthrosis at an early age due to poor coverage of the femoral head and abnormal loading of the joint articulation. In patients with symptomatic dysplasia and closed triradiate cartilage (generally over age 10), including adolescents and young adults (generally up to around age 40), the Bernese periacetabular osteotomy (PAO) is a durable technique for addressing underlying structural deformity. The PAO involves a modified Smith-Petersen approach. Advantages of the Bernese osteotomy include preservation of the weight-bearing posterior column of the hemi-pelvis, preservation of the acetabular blood supply, maintenance of the hip abductor musculature, and the ability to effect powerful deformity correction about an ideal center of rotation. There is an increasing body of evidence that preservation of the native hip can be improved through pelvic osteotomy. In contrast to hip osteotomy and joint preservation, the role of total hip arthroplasty in young, active patients with correctable hip deformity remains controversial. Moreover, the durability of hip replacement in young patients is inherently limited. Pelvic osteotomy should be considered the preferred method to address correctable structural deformity of the hip in the young, active patient with developmental dysplasia. The Bernese PAO is technically demanding, yet offers reproducible results with good long-term survivorship in carefully selected patients with preserved cartilage and the ability to meet the demands of rehabilitation. PMID:27190755

  8. Hip injuries in children and adolescents.

    Science.gov (United States)

    Craig, C L

    1980-10-01

    Hip injuries in children present a wide spectrum of problems. Frequently because of the severity of the trauma involved, other injuries may take precedence and may require modification of the usual approaches to treatment. However, certain precepts are essential to the successful treatment of these injuries and should be kept in mind regardless of the milieu in which they are found. In the child with a hip dislocation, the potential presence of an acetabular, femoral head, femoral shaft, patellar or tibial plateau fracture must always be considered. Specialized x-ray views are necessary for this evaluation. Laminography and arthrography may also be required. The essential feature of successful subsequent treatment is a gentle closed reduction performed within 24 hours of injury. Treatment of displaced fractures of the femoral neck remains an unresolved issue. Accurate reduction held with adequate internal fixation would appear to offer the best chance for a successful result. The possible complications of avascular necrosis, delayed union and non-union, coxa vara, premature closure of the epiphyseal plate, and shortening should be appreciated. Early institution of appropriate treatment may mitigate the ultimate effect of these potentially devastating problems. PMID:7454245

  9. Robot-assisted total hip arthroplasty.

    Science.gov (United States)

    Banerjee, Samik; Cherian, Jeffery J; Elmallah, Randa K; Pierce, Todd P; Jauregui, Julio J; Mont, Michael A

    2016-01-01

    Precise and accurate biomechanical reconstruction during total hip arthroplasty (THA) is essential for durable long-term survivorship. Accurate fit of cementless hip implants is also crucial to reduce micromotion between the bone-implant interfaces to allow for stable osseointegration. Robotic technology aims to minimize potential human errors and improve implant alignment and fit, and address persisting concerns with modern-day cementless THA. Although robotic THA dates back to the early 1990s, concerns with increased operating times, costs, and complications led to its withdrawal. However, semi-active systems have renewed interest in robot-assisted joint arthroplasty. We reviewed the current technology, its potential benefits, and the reported clinical and radiographic outcomes. Early evidence suggests that robotic use may lead to more accurate reconstruction of radiographic parameters, such as implant positioning, fit, center-of-rotation, and leg-length discrepancy. Further research is needed to determine if these will translate into better outcomes and improved implant longevity to justify increased costs. PMID:26592900

  10. Are Hip-Specific Items Useful in a Quality of Life Questionnaire for Patients with Hip Fractures?

    Science.gov (United States)

    Yao, Kai-Ping Grace; Lee, Hsin-Yi; Tsauo, Jau-Yih

    2009-01-01

    Researchers measure the significance of hip fracture by the patient's impairment. The patient's quality of life (QOL) is usually also substantially affected. However, there is no specific quality of life (QOL) questionnaire for patients with hip fractures. This study was designed to determine whether adding a new set of specific questions about…

  11. Hip Hop Culture's OGs: A Narrative Inquiry into the Intersection of Hip Hop Culture, Black Males and Their Schooling Experiences

    Science.gov (United States)

    Buchanan, Ian P.

    2013-01-01

    Using a critical race lens, this narrative study employs a focus group design to explore the intersections between black males, hip hop culture and schooling experiences. To provide a sociocultural grounding, this study first reviews the research literature around hip hop culture.s sociocultural development and its impact as a culture force that…

  12. Hip Ultrasonography in the Diagnosis of Developmental Dysplasia of the Hip: Bakırköy Experience

    Directory of Open Access Journals (Sweden)

    Altuğ Duramaz

    2014-12-01

    Full Text Available Aim: The purpose of the study was to determine the prevalence, incidence, and etiology as well as the risk factors for developmental dysplasia of the hip in newborns in whom we performed ultrasonography for screening using Graff’s method in our clinic. Methods: We retrospectively evaluated 2632 hip ultrasonography records of 1316 babies performed between 2008 and 2013. We analyzed the questionnaires of the Turkish Pediatric Orthopaedic Society which were filled by the physician during examination. The babies were divided into two groups according to ultrasonographic hip angles as pathological and normal. Results: The study is made on 1316 babies [680 girls (51.6%, 636 boys (48.4%]. The risk for developmental dysplasia of the hip was higher in girls, babies with a family history, babies with metatarsus adductus and those have been swaddled before. The mean gestational age and gestational weight was statistically significantly lower in the pathological group (p=0.0011. Conclusion: In our cross-sectional study, the incidence of developmental dysplasia of the hip was 0.5%. Female gender, positive family history of developmental dysplasia of the hip,metatarsus adductus and swaddling are still risk factors. Researching risk factors carefully, patient education and adding hip ultrasonograpy to newborn routine screening program are important measures in preventing developmental dysplasia of the hip.

  13. Red Flags Are Missed in the Prevention of Hip Fractures: Baseline Results of the Zurich Hip Fracture Trial

    Science.gov (United States)

    From January 2005 to December 2007, we recruited 173 patients age 65 and older with acute hip fracture and a Folstein mini mental score of at least 15 into an ongoing double-blind RCT with vitamin D. 69% of hip fracture patients were admitted from home and 31% from institutions, 79% were women. Mean...

  14. Hip-Hop Is My Passport! Using Hip-Hop and Digital Literacies to Understand Global Citizenship Education

    Science.gov (United States)

    Horton, Akesha Monique

    2013-01-01

    Hip-hop has exploded around the world among youth. It is not simply an American source of entertainment; it is a global cultural movement that provides a voice for youth worldwide who have not been able to express their "cultural world" through mainstream media. The emerging field of critical hip-hop pedagogy has produced little…

  15. Protocol of plain radiographs, hip ultrasound, and triple phase bone scans in the evaluation of the painful pediatric hip

    International Nuclear Information System (INIS)

    A useful protocol for the evaluation of hip pain in the pediatric patient, using a combination of plain radiographs, hip ultrasound (US), and triple phase radionuclide bone scans is presented. Patients with hip pain were initially evaluated by plain radiographs of the pelvis and hips. If no diagnosis was reached, the hips were studied for effusions by real-time hip ultrasonography. If an effusion was present, the joint was aspirated for diagnosis. If no effusion was present by US or if no diagnosis was reached by aspiration, triple phase radionuclide bone scans were performed. Fifty patients were evaluated by this prospective protocol, and the diagnosis was reached in 48 of the 50 cases (10 by plain radiographs, 16 by US, and aspiration of the joint, and 22 by triple phase bone scans). Hip effusions were found in 20 patients by US, with no false positives or false negatives. Previous studies for detecting effusions by US have emphasized absolute measurements of the capsular width, but we report a typical appearance of the hip capsule when fluid is present (a bulging convex capsule). When no effusion is present, the capsule is concave and parallels the long axis of the femoral neck

  16. Patient-reported outcome of hip resurfacing arthroplasty and standard total hip replacement after short-term follow-up

    DEFF Research Database (Denmark)

    Nissen, Tina Koerner; Douw, Karla; Overgaard, Søren

    2011-01-01

    The purpose of this study was to investigate patientreported outcome in terms of satisfaction in two study groups that had undergone hip resurfacing arthro-plasty (HRA) or total hip replacement (THR). The procedure consists of placing a hollow, mushroom-shaped metal cap over the femoral head while...

  17. Characterization of the Neural Anatomy in the Hip Joint to Optimize Periarticular Regional Anesthesia in Total Hip Arthroplasty.

    Science.gov (United States)

    Simons, Matthew J; Amin, Nirav H; Cushner, Fred D; Scuderi, Giles R

    2015-01-01

    The purpose of the current study was to identify and map the periarticular neural anatomy of the hip to optimize periarticular injection techniques in total hip arthroplasty. A literature review of common search engines was performed using terms associated with hip innervation and 17 met the inclusion criteria. The studies addressed both gross and microscopic neural anatomy of the human hip joint, and the findings summarize key areas of hip mechanoreceptors and free nerve endings to provide a framework for targeted periarticular hip infiltration. Grossly, the hip joint is supplied by the femoral, obturator, sciatic, and superior gluteal nerves, as well as the nerve to the quadratus femoris. The greatest concentration of sensory nerve endings and mechanoreceptors is found at the anterior hip capsule, especially superiorly. The labrum is most highly innervated from the 10 to 2 o'clock position. After the cup and liner are placed, periarticular injections should be infiltrated toward the remnant labrum from 10 to 2 o'clock. Before stem insertion, the visible periosteum may then be injected circumferentially about the femur. The anterior and superior capsular tissue, if retained, is routinely infiltrated at the time of capsular repair. Depending on surgical approach, the fascia and incised soft tissue are infiltrated before final closure. PMID:26731384

  18. The artificial leaf.

    Science.gov (United States)

    Nocera, Daniel G

    2012-05-15

    To convert the energy of sunlight into chemical energy, the leaf splits water via the photosynthetic process to produce molecular oxygen and hydrogen, which is in a form of separated protons and electrons. The primary steps of natural photosynthesis involve the absorption of sunlight and its conversion into spatially separated electron-hole pairs. The holes of this wireless current are captured by the oxygen evolving complex (OEC) of photosystem II (PSII) to oxidize water to oxygen. The electrons and protons produced as a byproduct of the OEC reaction are captured by ferrodoxin of photosystem I. With the aid of ferrodoxin-NADP(+) reductase, they are used to produce hydrogen in the form of NADPH. For a synthetic material to realize the solar energy conversion function of the leaf, the light-absorbing material must capture a solar photon to generate a wireless current that is harnessed by catalysts, which drive the four electron/hole fuel-forming water-splitting reaction under benign conditions and under 1 sun (100 mW/cm(2)) illumination. This Account describes the construction of an artificial leaf comprising earth-abundant elements by interfacing a triple junction, amorphous silicon photovoltaic with hydrogen- and oxygen-evolving catalysts made from a ternary alloy (NiMoZn) and a cobalt-phosphate cluster (Co-OEC), respectively. The latter captures the structural and functional attributes of the PSII-OEC. Similar to the PSII-OEC, the Co-OEC self-assembles upon oxidation of an earth-abundant metal ion from 2+ to 3+, may operate in natural water at room temperature, and is self-healing. The Co-OEC also activates H(2)O by a proton-coupled electron transfer mechanism in which the Co-OEC is increased by four hole equivalents akin to the S-state pumping of the Kok cycle of PSII. X-ray absorption spectroscopy studies have established that the Co-OEC is a structural relative of Mn(3)CaO(4)-Mn cubane of the PSII-OEC, where Co replaces Mn and the cubane is extended in a

  19. Application of uncemented Zweymüller hip prosthesis in adult patients with hip osteoarthritis secondary to developmental dysplasia

    Institute of Scientific and Technical Information of China (English)

    XU Yong-sheng; WANG Yan; LU Long; WEI Bao-gang

    2012-01-01

    Background Developmental dysplasia encompasses a wide spectrum of hip pathology ranging from a shallow acetabulum to a completely dislocated ‘high-riding' hip.It is a common cause of secondary osteoarthritis in young adults and is the underlying diagnosis in up to 48% of patients requiring total hip arthroplasty (THA) for coxarthrosis.The aim of this study was to evaluate efficiency and safety of THA using Zweymüller hip implant in the treatment of severe osteoarthritis secondary to developmental dysplasia of the hip (DDH) in adults.Methods From January 2000 to February 2008,35 patients (40 hips) with developmental dysplasia of the hip were included.Five were male and 30 were female,with ages ranging from 26 to 65 years and an average age of 45 years.According to Hartofilakidis classification,there were type Ⅰ in 5 hips,type Ⅱ in 20 hips,type Ⅲ in 15 hips.All the patients were performed the THA using the Zweymüller hip implant.The preoperative average Harris score was 44.The bilateral arthroplasty was performed in 5 patients and the unilateral arthroplasty in 30 patients.The patients mainly suffered from pain and claudication.Clinical and radiological results were analyzed.The Harris score was used for outcome measurement.Results Thirty five patients (40 hips) were followed and the mean follow-up period was 46 months (ranged from 24 months to 96 months).The latest follow-up average Harris score was 88.9 (97.1% of good rate).All the patients were pain-free and there was no sign of infection,aseptic loosening and subsidence.Conclusions In summary,THA using Zweymüller hip implant is a good treatment method for severe osteoarthritis secondary to DDH in adults.The key techniques for the total hip replacement are as follows:good preoperative plan,firmly placing the acetabular component in the true acetabulum,proper preparation of proximal femur,suitable femoral component choosing and improving the techniques of the bone graft.

  20. natural or artificial diets

    Directory of Open Access Journals (Sweden)

    A. O. Meyer-Willerer

    2005-01-01

    Full Text Available Se probaron alimentos artificiales y naturales con larva de camarón (Litopenaeus vannamei cultivados en diferentes recipientes. Estos fueron ocho frascos cónicos con 15L, ocho acuarios con 50L y como grupo control, seis tanques de fibra de vidrio con 1500L; todos con agua marina fresca y filtrada. La densidad inicial en todos los recipientes fue de 70 nauplios/L. Aquellos en frascos y acuarios recibieron ya sea dieta natural o artificial. El grupo control fue cultivado con dieta natural en los tanques grandes que utilizan los laboratorios para la producción masiva de postlarvas. El principal producto de excreción de larva de camarón es el ión amonio, que es tóxico cuando está presente en concentraciones elevadas. Se determinó diariamente con el método colorimétrico del indofenol. Los resultados muestran diferencias en la concentración del ión amonio y en la sobrevivencia de larvas entre las diferentes dietas y también entre los diferentes recipientes. En aquellos con volúmenes pequeños comparados con los grandes, se presentó mayor concentración de amonio (500 a 750µg/L, en aquellos con dietas naturales, debido a que este ión sirve de fertilizante a las algas adicionadas, necesitando efectuar recambios diarios de agua posteriores al noveno día de cultivo para mantener este ión a una concentración subletal. Se obtuvo una baja cosecha de postlarvas (menor a 15% con el alimento artificial larvario, debido a la presencia de protozoarios, alimentándose con el producto comercial precipitado en el fondo de los frascos o acuarios. Los acuarios con larvas alimentadas con dieta natural también mostraron concentraciones subletales de amonio al noveno día; sin embargo, la sobrevivencia fue cuatro veces mayor que con dietas artificiales. Los tanques control con dietas naturales presentaron tasas de sobrevivencia (70 ± 5% similares a la reportada por otros laboratorios.

  1. Artificial frustrated spin systems

    Science.gov (United States)

    Perrin, Y.; Chioar, I. A.; Nguyen, V. D.; Lacour, D.; Hehn, M.; Montaigne, F.; Canals, B.; Rougemaille, N.

    2015-09-01

    Complex architectures of nanostructures are routinely elaborated using bottom-up or nanofabrication processes. This technological capability allows scientists to engineer materials with properties that do not exist in nature, but also to manufacture model systems to explore fundamental issues in condensed matter physics. Two-dimensional frustrated arrays of magnetic nanostructures are one class of systems for which theoretical predictions can be tested experimentally. These systems have been the subject of intense research in the last few years and allowed the investigation of a rich physics and fascinating phenomena, such as the exploration of the extensively degenerate ground-state manifolds of spin ice systems, the evidence of new magnetic phases in purely two-dimensional lattices, and the observation of pseudoexcitations involving classical analogues of magnetic monopoles. We show here, experimentally and theoretically, that simple magnetic geometries can lead to unconventional, non-collinear spin textures. For example, kagome arrays of inplane magnetized nano-islands do not show magnetic order. Instead, these systems are characterized by spin textures with intriguing properties, such as chirality, coexistence of magnetic order and disorder, and charge crystallization. Magnetic frustration effects in lithographically patterned kagome arrays of nanomagnets with out-of-plane magnetization also lead to an unusal, and still unknown, magnetic ground state manifold. Besides the influence of the lattice geometry, the micromagnetic nature of the elements constituting the arrays introduce the concept of chiral magnetic monopoles, bringing additional complexity into the physics of artificial frustrated spin systems.

  2. Artificial Immune Systems Tutorial

    CERN Document Server

    Aickelin, Uwe

    2008-01-01

    The biological immune system is a robust, complex, adaptive system that defends the body from foreign pathogens. It is able to categorize all cells (or molecules) within the body as self-cells or non-self cells. It does this with the help of a distributed task force that has the intelligence to take action from a local and also a global perspective using its network of chemical messengers for communication. There are two major branches of the immune system. The innate immune system is an unchanging mechanism that detects and destroys certain invading organisms, whilst the adaptive immune system responds to previously unknown foreign cells and builds a response to them that can remain in the body over a long period of time. This remarkable information processing biological system has caught the attention of computer science in recent years. A novel computational intelligence technique, inspired by immunology, has emerged, called Artificial Immune Systems. Several concepts from the immune have been extracted an...

  3. Artificial Immune Systems

    CERN Document Server

    Aickelin, Uwe

    2009-01-01

    The biological immune system is a robust, complex, adaptive system that defends the body from foreign pathogens. It is able to categorize all cells (or molecules) within the body as self-cells or non-self cells. It does this with the help of a distributed task force that has the intelligence to take action from a local and also a global perspective using its network of chemical messengers for communication. There are two major branches of the immune system. The innate immune system is an unchanging mechanism that detects and destroys certain invading organisms, whilst the adaptive immune system responds to previously unknown foreign cells and builds a response to them that can remain in the body over a long period of time. This remarkable information processing biological system has caught the attention of computer science in recent years. A novel computational intelligence technique, inspired by immunology, has emerged, called Artificial Immune Systems. Several concepts from the immune have been extracted an...

  4. Probability and heritability estimates on primary osteoarthritis of the hip leading to total hip arthroplasty

    DEFF Research Database (Denmark)

    Skousgaard, Søren Glud; Hjelmborg, Jacob; Skytthe, Axel;

    2015-01-01

    additive genetic component of 47 % (12:79), a shared environmental component of 21 % (2:76) and a unique environment component of 32 % (21:41) accounted for the variation in population liability to total hip arthroplasty. The sex-adjusted proband-wise concordance and heritability on age indicated an...... significant and account for 68 % of the variation in the population liability to total hip arthroplasty; however, the genetic influence increases significantly from 60 years of age onwards....... for the period 1995 to 2010 were examined. Our main outcomes were the cumulative incidence, proband-wise concordance and heritability on age, within-pair correlations in monozygotic and dizygotic twin pairs, and the genetic and environmental influence estimated in models taking into account that...

  5. Let Me Blow Your Mind: Hip Hop Feminist Futures in Theory and Praxis

    Science.gov (United States)

    Lindsey, Treva B.

    2015-01-01

    This essay brings together key theoretical interventions in hip-hop feminism to explore the continued, but undervalued, significance of hip-hop feminism in urban education. More specifically, the essay challenges narrow conceptualizations of the "hip hop subject" as Black and male by using hip-hop feminist theory to incorporate the lived…

  6. Walking pattern in adults with congenital hip dysplasia: 14 women examined by inverse dynamics

    DEFF Research Database (Denmark)

    Pedersen, Eva Natalia G.; Simonsen, Erik B; Alkjaer, T;

    2004-01-01

    Knowledge of the gait dynamics in patients with hip dysplasia may help to understand the consequences of the mechanical changes in the hip.......Knowledge of the gait dynamics in patients with hip dysplasia may help to understand the consequences of the mechanical changes in the hip....

  7. Femoral component loosening after hip resurfacing arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Zustin, Jozef; Sauter, Guido [University Medical Centre Hamburg-Eppendorf, Institute of Pathology, Hamburg (Germany); Hahn, Michael [University Medical Centre Hamburg-Eppendorf, Center for Biomechanics and Skeletal Biology, Hamburg (Germany); Morlock, Michael M. [TUHH Hamburg University of Technology, Biomechanics Section, Hamburg (Germany); Ruether, Wolfgang [University Medical Centre Hamburg-Eppendorf, Department of Orthopaedics, Hamburg (Germany); Amling, Michael [University Medical Centre Hamburg-Eppendorf, Center for Biomechanics and Skeletal Biology, Hamburg (Germany); University Medical Centre Hamburg-Eppendorf, Department of Trauma, Hand and Reconstructive Surgery, Hamburg (Germany)

    2010-08-15

    Before the re-introduction of the current generation of total hip resurfacing arthroplasty, component loosening and osteolysis were of great concern to the orthopaedic community. Early, mid- and long-term clinical results are encouraging, but component loosening still exists. Macroscopic, contact radiographic and histopathological analyses after undecalcified preparation of bone tissue specimens were performed. To investigate the frequency and morphological patterns of the loosening of the femoral component, we analysed a series of 190 retrieved femoral remnants that were revised for aseptic failures. Thirty-five (18.4%) hips were revised for clinical and/or radiographic loosening of the femoral component. Pseudoarthrosis (n = 17; median in situ time: 16 weeks, interquartile range [IQR]: 9 to 34), collapsed osteonecrosis (n = 5; median in situ time: 79 weeks, IQR: 63 to 97), cement-socket debonding (n = 3; median in situ time: 89 weeks, IQR: 54 to 97) and at later follow-up bone-cement loosening (n = 10; median in situ time: 175 weeks; IQR 112 to 198; p =0.005) were distinct patterns of the femoral remnant-implant loosening. Fibrocartilaginous metaplasia of interface bone trabeculae (n = 38; median in situ time: 61 weeks, IQR: 32 to 138) was strongly associated with femoral component loosening (p = 0.009). Both the trabecular hyperosteoidosis (n = 32; median in situ time: 71 weeks, IQR 50 to 129) and excessive intraosseous lymphocyte infiltration (n = 12; median in situ time: 75 weeks, IQR 51 to 98) at the bone-cement interface correlated strongly with fibrocartilaginous metaplasia (p = 0.001 and p = 0.016 respectively) and all three lesions were associated with the female gender (p = 0.021, p = 0.009, and p = 0.051). Femoral component loosening at early follow-up was mostly caused by pathological changes of the femoral remnant bone tissue: pseudoarthrosis and collapsed osteonecrosis. Fibrocartilaginous metaplasia was frequently observed in hips with femoral

  8. External Snapping Hip Syndrome: Emphasis on the MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jung Eun; Lee, Bae Young [Catholic University St. Paul' s Hospital, Seoul (Korea, Republic of); Sung, Mi Sook; Lee, Ki Haeng; Yoo, Won Jong; Lim, Hyun Wook; Chung, Myung Hee [Catholic University Bucheon St. Mary' s Hospital, Bucheon (Korea, Republic of); Park, Jeong Mi [Catholic University St. Mary' s Hospital, Seoul (Korea, Republic of); Kim, Jee Young [Catholic University St. Vincent' s Hospital, Suwon (Korea, Republic of)

    2010-02-15

    The aim of this study is to evaluate the MR imaging features of patients with external snapping hip syndrome. We retrospectively reviewed 63 hip MR images. The images were analyzed according to the thickness and contour of the iliotibial band and the gluteus maximus, the presence of bone marrow edema, bursitis, joint effusion and other associated findings. The MR imaging of 22 hips with snapping hip syndrome depicted the causes of external snapping hip syndrome in twenty cases (90%). The MR imaging features of the snapping hip included thickening of the iliotibial band in twelve cases (55%) and/or thickening of the anterior band of the gluteus maximus in nineteen (86%), and a wavy contour of the iliotibial band or the anterior band of the gluteus maximus in ten cases (45%). These findings show a significant p value (<0.01). The majority of patients with snapping hip syndrome revealed thickening of the iliotibial band, thickening of the anterior band of the gluteus maximus and wavy contour of the those structures on MR imaging.

  9. Assessment of hip dysplasia and osteoarthritis: Variability of different methods

    Energy Technology Data Exchange (ETDEWEB)

    Troelsen, Anders; Elmengaard, Brian; Soeballe, Kjeld (Orthopedic Research Unit, Univ. Hospital of Aarhus, Aarhus (Denmark)), e-mail: a_troelsen@hotmail.com; Roemer, Lone (Dept. of Radiology, Univ. Hospital of Aarhus, Aarhus (Denmark)); Kring, Soeren (Dept. of Orthopedic Surgery, Aabenraa Hospital, Aabenraa (Denmark))

    2010-03-15

    Background: Reliable assessment of hip dysplasia and osteoarthritis is crucial in young adults who may benefit from joint-preserving surgery. Purpose: To investigate the variability of different methods for diagnostic assessment of hip dysplasia and osteoarthritis. Material and Methods: By each of four observers, two assessments were done by vision and two by angle construction. For both methods, the intra- and interobserver variability of center-edge and acetabular index angle assessment were analyzed. The observers' ability to diagnose hip dysplasia and osteoarthritis were assessed. All measures were compared to those made on computed tomography scan. Results: Intra- and interobserver variability of angle assessment was less when angles were drawn compared with assessment by vision, and the observers' ability to diagnose hip dysplasia improved when angles were drawn. Assessment of osteoarthritis in general showed poor agreement with findings on computed tomography scan. Conclusion: We recommend that angles always should be drawn for assessment of hip dysplasia on pelvic radiographs. Given the inherent variability of diagnostic assessment of hip dysplasia, a computed tomography scan could be considered in patients with relevant hip symptoms and a center-edge angle between 20 deg and 30 deg. Osteoarthritis should be assessed by measuring the joint space width or by classifying the Toennis grade as either 0-1 or 2-3

  10. Frequency of Developmental Hip Dysplasia in a Training Hospital

    Directory of Open Access Journals (Sweden)

    Emrah Can

    2010-09-01

    Full Text Available Aim: We aimed to determine the frequency of cases with developmental hip dysplasia during the neonatal period and the associated risk factors. Methods: Hip ultrasound images of 258 full-term newborns aged one month were evaluated prospectively in conjunction with physical examination for developmental hip dysplasia in GATA well baby outpatient clinic. Results: The incidence of developmental hip dysplasia was 0.3% in one-month-old, healthy, full-term babies included in the study. 44% of them were male and 56% were female. The mean birth weight was 3311.8±511.4 g. 48% of all births were spontaneous vaginal deliveries and 52% cesarean deliveries. A history of oligohydramniosis was present in 8% of cases, 1% had breech presentation, 7% had a family history of developmental dysplasia and 7% had been swaddled. Additional congenital anomaly and torticollis were not detected at the physical examination of the babies. The risk factors were determined to be twin birth and female gender in the only baby who had developmental hip dysplasia (Type 2a. Conclusion: Developmental hip displasia is a significant public health concern in developing countries. Physical examination performed in conjunction with hip ultrasonography routinely in the neonatal period may contribute to the early diagnosis and treatment. (The Medical Bulletin of Haseki 2010; 48: 99-102

  11. MR imaging of transient osteoporosis of the hip: An update on 155 hip joints

    International Nuclear Information System (INIS)

    Highlights: •Characteristics of TOH are described based on the largest series of patients in the literature. •The chance of regional migratory osteoporosis progression is estimated to be 19.4%. •The pattern of bone marrow edema with respect to symptom duration is described. •The prevalence of subchondral microfractures is high in TOH patients. •Microfractures are not complicated with avascular necrosis or articular collapse. -- Abstract: Purpose: Transient osteoporosis of the hip (TOH) presents with acute onset pain and bone marrow edema (BMe) on MR imaging. The purpose of this study is to revise the MR imaging characteristics of TOH by analyzing the data derived from 155 hip examinations. We also sought to explore the relationship between the duration of symptoms and the presence of sparing and subchondral fractures. Materials and methods: MR images of 155 hips (141 TOH patients) were retrospectively evaluated for the presence of insufficiency fractures and the morphology of BMe. Sparing of the medial bone marrow of the femoral head was recorded together with demographic and clinical data. Progression to regional migratory osteoporosis (RMO) and postpartum cases were also recorded. Results: Our population consisted of 76.4% male and 23.6% female patients. RMO progression was recorded in 19.4% and 4 postpartum cases displayed bilateral disease. Sparing of the medial bone marrow was present at 87.7% of patients and disappeared as the disease progressed (P = 0.005). BMe was restricted within the femoral head in 11.0%, extended to the femoral neck in 40% and to the femoral shaft in 49% of the cases studied. Subchondral fractures were present at 48.7% of the hips. Conclusion: This study describes TOH patient characteristics, the MR imaging findings (BMe pattern, microfractures), their association with symptom duration and the chance of progressing to RMO

  12. MR imaging of transient osteoporosis of the hip: An update on 155 hip joints

    Energy Technology Data Exchange (ETDEWEB)

    Klontzas, Michail E.; Vassalou, Evangelia E. [Department of Medical Imaging, University Hospital of Heraklion, Medical School, University of Crete (Greece); Zibis, Aristeidis H. [Department of Anatomy, University of Thessalia, Medical School, Larissa (Greece); Bintoudi, Antonia S. [Department of Radiology, “Papageorgiou” General Hospital of Thessaloniki (Greece); Karantanas, Apostolos H., E-mail: akarantanas@gmail.com [Department of Medical Imaging, University Hospital of Heraklion, Medical School, University of Crete (Greece)

    2015-03-15

    Highlights: •Characteristics of TOH are described based on the largest series of patients in the literature. •The chance of regional migratory osteoporosis progression is estimated to be 19.4%. •The pattern of bone marrow edema with respect to symptom duration is described. •The prevalence of subchondral microfractures is high in TOH patients. •Microfractures are not complicated with avascular necrosis or articular collapse. -- Abstract: Purpose: Transient osteoporosis of the hip (TOH) presents with acute onset pain and bone marrow edema (BMe) on MR imaging. The purpose of this study is to revise the MR imaging characteristics of TOH by analyzing the data derived from 155 hip examinations. We also sought to explore the relationship between the duration of symptoms and the presence of sparing and subchondral fractures. Materials and methods: MR images of 155 hips (141 TOH patients) were retrospectively evaluated for the presence of insufficiency fractures and the morphology of BMe. Sparing of the medial bone marrow of the femoral head was recorded together with demographic and clinical data. Progression to regional migratory osteoporosis (RMO) and postpartum cases were also recorded. Results: Our population consisted of 76.4% male and 23.6% female patients. RMO progression was recorded in 19.4% and 4 postpartum cases displayed bilateral disease. Sparing of the medial bone marrow was present at 87.7% of patients and disappeared as the disease progressed (P = 0.005). BMe was restricted within the femoral head in 11.0%, extended to the femoral neck in 40% and to the femoral shaft in 49% of the cases studied. Subchondral fractures were present at 48.7% of the hips. Conclusion: This study describes TOH patient characteristics, the MR imaging findings (BMe pattern, microfractures), their association with symptom duration and the chance of progressing to RMO.

  13. Artificial Life Meets Computational Creativity?

    OpenAIRE

    McMullin, Barry

    2009-01-01

    I (briefly) review the history of work in Artificial Life on the problem of the open-ended evolutionary growth of complexity in computational worlds. This is then put into the context of evolutionary epistemology and human creativity.

  14. Darwin, artificial selection, and poverty.

    Science.gov (United States)

    Sanchez, Luis

    2010-03-01

    This paper argues that the processes of evolutionary selection are becoming increasingly artificial, a trend that goes against the belief in a purely natural selection process claimed by Darwin's natural selection theory. Artificial selection is mentioned by Darwin, but it was ignored by Social Darwinists, and it is all but absent in neo-Darwinian thinking. This omission results in an underestimation of probable impacts of artificial selection upon assumed evolutionary processes, and has implications for the ideological uses of Darwin's language, particularly in relation to poverty and other social inequalities. The influence of artificial selection on genotypic and phenotypic adaptations arguably represents a substantial shift in the presumed path of evolution, a shift laden with both biological and political implications. PMID:20812798

  15. Artificial Reefs and Ocean Dumping.

    Science.gov (United States)

    Glueck, Richard D.

    1983-01-01

    Activities and instructional strategies for two multigrade lessons are provided. Activity objectives include describing an artificial reef (such as a sunken ocean liner) as an ecosystem, knowing animal types in the ecosystem, and describing a food web. (JN)

  16. Artificial Intelligence in Civil Engineering

    Directory of Open Access Journals (Sweden)

    Pengzhen Lu

    2012-01-01

    Full Text Available Artificial intelligence is a branch of computer science, involved in the research, design, and application of intelligent computer. Traditional methods for modeling and optimizing complex structure systems require huge amounts of computing resources, and artificial-intelligence-based solutions can often provide valuable alternatives for efficiently solving problems in the civil engineering. This paper summarizes recently developed methods and theories in the developing direction for applications of artificial intelligence in civil engineering, including evolutionary computation, neural networks, fuzzy systems, expert system, reasoning, classification, and learning, as well as others like chaos theory, cuckoo search, firefly algorithm, knowledge-based engineering, and simulated annealing. The main research trends are also pointed out in the end. The paper provides an overview of the advances of artificial intelligence applied in civil engineering.

  17. Comparison of radiographic and radionuclide hip arthrography in determination of femoral component loosening of hip arthroplasties

    International Nuclear Information System (INIS)

    Radiographic examination of a patient experiencing pain following total hip arthroplasty is an important step in the systematic approach to evaluating component loosening, even though the information yielded is often equivocal and nondiagnostic in assessing component loosening. The radiographic criteria for loosening are especially difficult to assess following revision surgery, for radiolucent lines frequently exist at the bone-cement interface immediately following implantation. The advent of noncemented hip prostheses poses another problem: the routinely noted disruption of bone-cement of prosthesis-cement interfaces is not present with uncemented prostheses. As the criteria for loosening of the noncemented prostheses are still evolving, plain radiographic examination is frequently nondiagnostic. Femoral component loosening is difficult to detect with standard contrast arthrography because the bone, metal, surrounding radiopaque cement and contrast agents have similar or identical radiographic appearances. In contrast arthrography, if the prosthesis is loose the injected agent opacifies the radiolucent zone encircling the prosthesis or cement mangle. Because of the similarity in the appearances of these agents and the surrounding structures on x-ray films, interpretation is difficult. The inclusion of subtraction techniques in routine contrast arthrography has improved its accuracy; however, these techniques require special equipment and demand precise patient positioning. The purpose of this study is to introduce a new form of hip arthrography using a radionuclide agent in place of the contrast agent. A comparison of the results using these two techniques is presented

  18. The handbook of artificial intelligence

    CERN Document Server

    Barr, Avron

    1982-01-01

    The Handbook of Artificial Intelligence, Volume II focuses on the improvements in artificial intelligence (AI) and its increasing applications, including programming languages, intelligent CAI systems, and the employment of AI in medicine, science, and education. The book first elaborates on programming languages for AI research and applications-oriented AI research. Discussions cover scientific applications, teiresias, applications in chemistry, dependencies and assumptions, AI programming-language features, and LISP. The manuscript then examines applications-oriented AI research in medicine

  19. Rewritable Artificial Magnetic Charge Ice

    OpenAIRE

    Wang, Yong-Lei; Xiao, Zhi-Li; Snezhko, Alexey; Xu, Jing; Ocola, Leonidas E.; Divan, Ralu; Pearson, John E.; Crabtree, George W.; Kwok, Wai-Kwong

    2016-01-01

    Artificial ices enable the study of geometrical frustration by design and through direct observation. However, it has proven difficult to achieve tailored long-range ordering of their diverse configurations, limiting both fundamental and applied research directions. We designed an artificial spin structure that produces a magnetic charge ice with tunable long-range ordering of eight different configurations. We also developed a technique to precisely manipulate the local magnetic charge state...

  20. Medical applications of artificial intelligence

    CERN Document Server

    Agah, Arvin

    2013-01-01

    Enhanced, more reliable, and better understood than in the past, artificial intelligence (AI) systems can make providing healthcare more accurate, affordable, accessible, consistent, and efficient. However, AI technologies have not been as well integrated into medicine as predicted. In order to succeed, medical and computational scientists must develop hybrid systems that can effectively and efficiently integrate the experience of medical care professionals with capabilities of AI systems. After providing a general overview of artificial intelligence concepts, tools, and techniques, Medical Ap