WorldWideScience

Sample records for arthroplasty replacement finger

  1. Joint Replacement (Finger and Wrist Joints)

    Science.gov (United States)

    ... Symptom Picker Hand and Arm Conditions Carpal Tunnel Ganglion Cysts Trigger Finger Arthritis Base of the Thumb See ... Symptom Picker Hand and Arm Conditions Carpal Tunnel Ganglion Cysts Trigger Finger Arthritis Base of the Thumb See ...

  2. Total Hip Replacement (Arthroplasty) (Beyond the Basics)

    Science.gov (United States)

    ... stiffening caused by extra bone formation, also called heterotopic ossification, is a process in which some soft ... replacement (prosthetic) parts, with the goal of relieving pain and improving function. ● Most patients require total hip ...

  3. Shoulder replacement - discharge

    Science.gov (United States)

    Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; ...

  4. Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state

    Directory of Open Access Journals (Sweden)

    Harvinder Singh

    2011-01-01

    Full Text Available Surface replacement arthroplasty for proximal interphalangeal joint and metacarpophalangeal joints are becoming popular. Low profile, anatomically designed implants limit the amount of bone removed but need preservation of the collateral ligaments. Pyrocarbon and cobalt-chrome stemmed unconstrained implants on ultra-high molecular weight polyethylene are the two commonly available bearing surfaces. The indications for small joint arthroplasty are degenerative, post-traumatic or rheumatoid arthritis. Early results are encouraging, primarily in patient satisfaction and pain relief, but are based on low numbers. The main concerns are progressive loss of range due to implant settling, dislocation, squeaking and poor osteo-integration with the appearance of a radiolucent line at the bone-implant interface. Our experience suggests that metacarpophalangeal joint replacements consistently give good results.

  5. Dabigatran Etexilate, A Novel Oral Direct Thrombin Inhibitor, for Preventing Thromboembolic Events After Knee Replacement Arthroplasty

    OpenAIRE

    Yegane A; Farahini H; Shahhoseini Gh; Moghtadaee M; Rajabpour S

    2012-01-01

    Background: Dabigatran etexilate is one of the few direct thrombin inhibitors with anti-coagulant activities and the following distinctive features: taken orally, no need to closely monitor for complications, and no need for regular dose adjustments. Relying on the above mentioned valuable advantages, dabigatran etexilate can be considered as a premier choice for the prevention of venous thromboembolism after knee replacement arthroplasty. Methods: Forty five patients undergoing 50 knee repla...

  6. A study on the usefulness of total hip replacement arthroplasty using fluoroscopy

    International Nuclear Information System (INIS)

    To make a comparative analysis for clinical application of total hip replacement arthroplasty (THRA) using fluoroscopy, we have performed total hip replacement arthroplasty making 30 patients an object with general radiography and fluoroscopy respectively. The results are follows: 1) reexamination rate was 80 percent of patients and mean 3.9 sheets in the general radiography, where as it was 46.7 percent and 0.37 sheets in the fluoroscopy (p < 0.01). 2) Add examination was 2 cases in the general radiography, but fluoroscopy was no add examination. 3) The total film sheet used was mean 10.16 in the general radiography and 6.73 in the fluoroscopy. 4) In the cause of reexamination and add examination, inaccurate position of patient accounted for 72.6 percent in the general radiography and poor exposure condition accounted for 45.5 percent in the fluoroscopy. Total hip replacement arthroplasty using the fluoroscopy decreased reexamination and add examination rate, for these reasons, this method was effective abatement of pain, exposure radiation dose, and the examination time and so on. (author)

  7. Total Knee Replacement Arthroplasty with Buechel and Pappas Knee: Minimum 2-Year Follow-up

    OpenAIRE

    Moon, Kyoung Ho; Hong, Seung Hyun; Hong, Taek Ho

    2015-01-01

    Background Clinical and radiologic evaluation and analyses of the surgeries using Buechel and Pappas (B-P) knee implants. Methods The study was conducted on 60 patients who underwent 94 total knee replacement arthroplasty with B-P knee implants from May 2009 to December 2010. The results were compared to the results of 41 patients who underwent 60 knee joint surgeries using NexGen-LPS implants from January 2008 to August 2009. Results The American Knee Society score of the B-P knee group incr...

  8. Patient-reported outcome of hip resurfacing arthroplasty and standard total hip replacement after short-term follow-up

    DEFF Research Database (Denmark)

    Nissen, Tina Koerner; Douw, Karla; Overgaard, Søren

    2011-01-01

    The purpose of this study was to investigate patientreported outcome in terms of satisfaction in two study groups that had undergone hip resurfacing arthro-plasty (HRA) or total hip replacement (THR). The procedure consists of placing a hollow, mushroom-shaped metal cap over the femoral head while...

  9. Efficient immunoglobulin gene disruption and targeted replacement in rabbit using zinc finger nucleases.

    Directory of Open Access Journals (Sweden)

    Tatiana Flisikowska

    Full Text Available Rabbits are widely used in biomedical research, yet techniques for their precise genetic modification are lacking. We demonstrate that zinc finger nucleases (ZFNs introduced into fertilized oocytes can inactivate a chosen gene by mutagenesis and also mediate precise homologous recombination with a DNA gene-targeting vector to achieve the first gene knockout and targeted sequence replacement in rabbits. Two ZFN pairs were designed that target the rabbit immunoglobulin M (IgM locus within exons 1 and 2. ZFN mRNAs were microinjected into pronuclear stage fertilized oocytes. Founder animals carrying distinct mutated IgM alleles were identified and bred to produce offspring. Functional knockout of the immunoglobulin heavy chain locus was confirmed by serum IgM and IgG deficiency and lack of IgM(+ and IgG(+ B lymphocytes. We then tested whether ZFN expression would enable efficient targeted sequence replacement in rabbit oocytes. ZFN mRNA was co-injected with a linear DNA vector designed to replace exon 1 of the IgM locus with ∼1.9 kb of novel sequence. Double strand break induced targeted replacement occurred in up to 17% of embryos and in 18% of fetuses analyzed. Two major goals have been achieved. First, inactivation of the endogenous IgM locus, which is an essential step for the production of therapeutic human polyclonal antibodies in the rabbit. Second, establishing efficient targeted gene manipulation and homologous recombination in a refractory animal species. ZFN mediated genetic engineering in the rabbit and other mammals opens new avenues of experimentation in immunology and many other research fields.

  10. A comprehensive joint replacement program for total knee arthroplasty: a descriptive study

    Directory of Open Access Journals (Sweden)

    Prefontaine Paul

    2008-11-01

    Full Text Available Abstract Background Total knee arthroplasty (TKA is a commonly performed surgical procedure in the US. It is important to have a comprehensive inpatient TKA program which maximizes outcomes while minimizing adverse events. The purpose of this study was to describe a TKA program – the Joint Replacement Program (JRP – and report post-surgical outcomes. Methods 74 candidates for a primary TKA were enrolled in the JRP. The JRP was designed to minimize complications and optimize patient-centered outcomes using a team approach including the patient, patient's family, and a multidisciplinary team of health professionals. The JRP consisted of a pre-operative class, standard pathways for medical care, comprehensive peri-operative pain management, aggressive physical therapy (PT, and proactive discharge planning. Measures included functional tests, knee range of motion (ROM, and medical record abstraction of patient demographics, length of stay, discharge disposition, and complications over a 6-month follow-up period. Results All patients achieved medical criteria for hospital discharge. The patients achieved the knee flexion ROM goal of 90° (91.7 ± 5.4°, but did not achieve the knee extension ROM goal of 0° (2.4 ± 2.6°. The length of hospital stay was two days for 53% of the patients, with 39% and 7% discharged in three and four days, respectively. All but three patients were discharged home with functional independence. 68% of these received outpatient physical therapy compared with 32% who received home physical therapy immediately after discharge. Two patients ( Conclusion The comprehensive JRP for TKA was associated with satisfactory clinical outcomes, short lengths of stay, a high percentage of patients discharged home with outpatient PT, and minimal complications. This JRP may represent an efficient, effective and safe protocol for providing care after a TKA.

  11. 99mTc-HMPAO-labelled leucocyte scintigraphy in the diagnosis of infection after total knee replacement arthroplasty

    International Nuclear Information System (INIS)

    This study was performed to evaluate the usefulness of 99mTc-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy. The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age: 65 years) who had total knee replacement arthroplasty. After injection of 99mTc-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection: Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positive, one false positive and three true negative in Group B, and six true negatives and two false positive in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively. 99mTc-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity

  12. Bryan total disc arthroplasty: a replacement disc for cervical disc disease

    OpenAIRE

    Wenger, Markus

    2010-01-01

    Markus Wenger1, Thomas-Marc Markwalder21Neurosurgery, Klinik Beau-Site and Salem-Spital, Berne, Switzerland; 2Attending Neurosurgeon FMH, Private Practice Spine Surgery, Berne-Muri, SwitzerlandAbstract: Total disc arthroplasty is a new option in the treatment of cervical degenerative disc disease. Several types of cervical disc prostheses currently challenge the gold-standard discectomy and fusion procedures. This review describes the Bryan Cervical Disc System and presents the Bryan prosthes...

  13. Medium-term evaluation of total knee arthroplasty without patellar replacement

    Directory of Open Access Journals (Sweden)

    José Wanderley Vasconcelos

    2013-06-01

    Full Text Available OBJECTIVE: To mid-term evaluate patients who were submitted to total knee arthroplasty without patellar resurfacing. METHODS: It was realized a retrospective cross-sectional study of patients who were submitted to total knee arthroplasty without patellar resurfacing. In all patients clinical examination was done based on the protocol of the Knee Society Scoring System, which assessed pain, range of motion, stability, contraction, knee alignment and function, and radiological evaluation. RESULTS: A total of 36 patients were evaluated. Of these, 07 were operated only on left knee, 12 only on right knee and 17 were operated bilaterally, totaling 53 knees. Ages ranged from 26 to 84 years. Of the 53 knees evaluated, 33 (62.26% had no pain. The maximum flexion range of motion averaged 104.7°. No knee had difficulty in active extension. As to the alignment for anatomical axis twelve knees (22.64% showed deviation between 0° and 4° varus. Thirty-nine (75.49% knees showed pace without restriction and the femorotibial angle ranged between 3° varus and 13° valgus with an average of 5° valgus. The patellar index ranged from 0.2 to 1.1. CONCLUSION: Total knee arthroplasty whitout patellar resurfacing provides good results in mid-term evaluation.

  14. Fracture of the Anterior Locking Flange of a Total Knee Arthroplasty Polyethylene Liner Presenting with Pain following Knee Replacement

    Science.gov (United States)

    Jeavons, Richard; Dowen, Daniel; Rushton, Paul; Ryan, Daniel; Gill, Peter

    2014-01-01

    Introduction: Fracture of the modern polyethylene insert of a total knee arthroplasty is rare. We describe the first case of a fractured anterior locking flange of the commonly used Depuy Press-fit Condylar (PFC) Sigma prosthesis. Case Report: The 80 year old Caucasian gentleman presented 8 years following previously uncomplicated and successful primary total knee replacement with pain, swelling and symptoms of instability of the knee. He was able to sublux his knee posteriorly using his hamstrings. Dissociation of the liner was evident on radiographs. He underwent revision of the polyethylene liner. It was evident during the revision that the anterior locking flange of the polyethylene liner had fractured allowing it to dissociate from the tibial tray. At 12 months following this revision he continues to do well and has similar range of movement and function to prior to the episode. This cause of the failure is not clear. Conclusion: Surgeons should be aware of this rare complication when assessing a painful or unstable total knee replacement. PMID:27298962

  15. Countrywise results of total hip replacement An analysis of 438,733 hips based on the Nordic Arthroplasty Register Association database

    DEFF Research Database (Denmark)

    Makela, K. T.; Matilainen, M.; Pulkkinen, P.;

    2014-01-01

    Background and purpose An earlier Nordic Arthroplasty Register Association (NARA) report on 280,201 total hip replacements (THRs) based on data from 1995-2006, from Sweden, Norway, and Denmark, was published in 2009. The present study assessed THR survival according to country, based on the NARA ...... (HR = 0.59, CI: 0.36-0.98) year of follow-up. Interpretation The differences in THR survival rates were considerable, with inferior results in Finland. Brand-level comparison of THRs in Nordic countries will be required.......Background and purpose An earlier Nordic Arthroplasty Register Association (NARA) report on 280,201 total hip replacements (THRs) based on data from 1995-2006, from Sweden, Norway, and Denmark, was published in 2009. The present study assessed THR survival according to country, based on the NARA...... 84% (CI: 82.9-84.1) in Finland. Revision risk for all THRs was less in Sweden than in the 3 other countries during the first 5 years. However, revision risk for uncemented THR was less in Denmark than in Sweden during the sixth (HR = 0.53, CI: 0.34-0.82), seventh (HR = 0.60, CI: 0.37-0.97), and ninth...

  16. Arthroplasty register for Germany

    OpenAIRE

    Hagen, Anja; Gorenoi, Vitali; Schönermark, Matthias P.

    2009-01-01

    Scientific background The annual number of joint replacement operations in Germany is high. The introduction of an arthroplasty register promises an important contribution to the improvement of the quality of patient's care. Research questions The presented report addresses the questions on organization and functioning, benefits and cost-benefits as well as on legal, ethical and social aspects of the arthroplasty registers. Methods A systematic literature search ...

  17. Total hip replacement in young adults with hip dysplasia. Age at diagnosis, previous treatment, quality of life, and validation of diagnoses reported to the Norwegian Arthroplasty Register between 1987 and 2007

    OpenAIRE

    Engesæter, Ingvild Øvstebø; Lehmann, Trude; Laborie, Lene Bjerke; Lie, Stein Atle; Rosendahl, Karen; Engesæter, Lars B

    2011-01-01

    Background and purpose: Dysplasia of the hip increases the risk of secondary degenerative change and subsequent total hip replacement. Here we report on age at diagnosis of dysplasia, previous treatment, and quality of life for patients born after 1967 and registered with a total hip replacement due to dysplasia in the Norwegian Arthroplasty Register. We also used the medical records to validate the diagnosis reported by the orthopedic surgeon to the register.Methods: Sub...

  18. CLINICAL STUDY ON PATELLAR REPLACEMENT IN TOTAL KNEE ARTHROPLASTY%人工全膝关节置换术中髌骨置换的临床研究

    Institute of Scientific and Technical Information of China (English)

    鲍亮; 高智慧; 施小强; 房晓敏; 金群华

    2013-01-01

    目的 通过与非髌骨置换比较,探讨髌骨置换对人工全膝关节置换术疗效的影响. 方法 将2010年9月-11月符合选择标准的63例(63膝)拟行人工全膝关节置换术的骨关节炎患者随机分为两组,其中32例关节置换术中行髌骨置换(置换组),31例不作置换(非置换组).两组患者性别、年龄、病程、骨关节炎分级、美国膝关节协会评分系统(KSS)标准临床评分及关节功能评分、髌骨评分、髌骨倾斜角、胫股角及髌韧带比值等一般资料比较,差异均无统计学意义(P>0.05),具有可比性.术后6周及3、6、12个月对疗效进行临床及影像学评定. 结果 两组患者术后切口均Ⅰ期愈合,置换组6例、非置换组8例出现下肢深静脉血栓形成.患者均获12个月随访.置换组术后3、6、12个月时膝前疼痛发生率均低于非置换组(P<0.05).两组术后各时间点KSS临床评分比较,差异无统计学意义(P>0.05);除术后6周及3个月,其余各时间点置换组关节功能评分明显高于非置换组(P<0.05).两组髌骨评分除术后12个月外,其余各时间点组间比较差异均无统计学意义(D>0.05).X线片复查示,两组均无髌骨骨折、髌骨脱位、髌骨不稳、假体松动及断裂发生;术后12个月两组股胫角、髌韧带比值、髌骨倾斜角比较,差异均无统计学意义(P> 0.05). 结论 人工全膝关节置换术中行髌骨置换可以一定程度改善膝关节功能评分、髌骨评分及降低术后膝前疼痛的发生率.%Objective To evaluate the influence of patellar replacement on total knee arthroplasty by comparing with non pattelar replacement. Methods Between September 2010 and November 2010, 63 patients (63 knees) with osteoarthritis who met the selection criteria and underwent total knee arthroplasty, were randomly divided into 2 groups: patellar replacement in 32 cases (replacement group), non patellar replacement in 31 cases (non pattelar

  19. Elbow replacement - discharge

    Science.gov (United States)

    Total elbow arthroplasty - discharge; Endoprosthetic elbow replacement - discharge ... You had surgery to replace your elbow joint with artificial joint parts (prosthetics). The surgeon made a cut (incision) in the back of your upper or lower arm and ...

  20. The efficacy of 99mTc-ciprofloxacin (infecton) imaging in suspected prosthetic infection following total knee replacement arthroplasty (pilot study)

    International Nuclear Information System (INIS)

    The aims of this study were 1) to increase the labelling efficiency of 99mTc-ciprofloxacin (infecton) and 2) to determine the value of infecton imaging in demonstrating infection following total knee replacement arthroplasty (TKRA). Five patients (4 female, 1 male: mean age 52.8±13.5 years, both TKRA in 3 pt) with suspected prosthetic infective conditions were included. In order to increase labelling efficiency, infection was labelled with stannous tartrate instead of previousely used formamidine sulfinic acid (FSA). Immediate perfusion, 5min blood pool, 1hr, 4hr and 24hr delayed images were perfomed. All images were blindly interpreted by two independent observers with visual findings being classified according to a four-grade scale(0.1.2.3). Images graded 0 and 1, and also those regions which showed faintly increase or unchanged uptake grade on late images as compared with early images, were classified as negative; grades 2 and 3 were classified as positive. The diagnosis was confirmed by intraoperative microbiological / histological findings or by the presence of gross purulence. Labelling efficiency increased up to over 98% with formation of radiocolloid less than 1%. All of four pt with prosthetic infection showed positive infecton images but one pt with sterile loosening of prosthesis showed negative infection images. The easy availability as well as new labelling technique make infecton imaging the better option for the detection of prosthetic orthopedic infection

  1. Risk of cancer following primary total hip replacement or primary resurfacing arthroplasty of the hip: a retrospective cohort study in Scotland

    OpenAIRE

    Brewster, D H; Stockton, D L; Reekie, A; Ashcroft, G. P.; Howie, C R; Porter, D E; Black, R. J.

    2013-01-01

    Background: Release and dispersion of particles arising from corrosion and wear of total hip arthroplasty (THA) components has raised concerns about a possible increased risk of cancer. Concerns have been heightened by a recent revival in the use of metal-on-metal (MoM) hip prostheses. Methods: From a linked database of hospital discharge, cancer registration, and mortality records, we selected a cohort of patients who underwent primary THA (1990–2009) or primary resurfacing arthroplasty (mai...

  2. Introduction of total knee arthroplasty in Lithuania

    OpenAIRE

    Tarasevicius, Sarunas; Stucinskas, Justinas; Robertsson, Otto; Wingstrand, Hans

    2009-01-01

    Background and purpose We have previously reported that the first 10 years of hip arthroplasty in Lithuania resulted in a higher cumulative revision rate than that observed in Sweden. We thus compared the corresponding results after introduaction of total knee replacement in Lithuania. Methods The 10-year revision rate for the first 595 primary ScanKnee arthroplasties inserted in Klaipeda, Lithuania, was compared to that for the first 1,280 ScanKnee primary arthroplasties inserted in Sweden. ...

  3. Clinical and radiologic comparison of dynamic cervical implant arthroplasty and cervical total disc replacement for single-level cervical degenerative disc disease.

    Science.gov (United States)

    Shichang, Liu; Yueming, Song; Limin, Liu; Lei, Wang; Zhongjie, Zhou; Chunguang, Zhou; Xi, Yang

    2016-05-01

    Anterior cervical discectomy and fusion, to date the most successful spine procedure for the surgical treatment of cervical radiculopathy, has limitations that have led to the development of non-fusion cervical procedures, such as cervical total disc replacement (TDR) and dynamic cervical implant (DCI) arthroplasty. We compared the clinical and radiological results of DCI and cervical TDR for the treatment of single-level cervical degenerative disc disease in Chinese patients. A retrospective review of 179 patients with cervical spondylotic myelopathy who underwent DCI or TDR between April 2010 and October 2012 was conducted, and 152 consecutive patients (67 patients single-level DCI and 85 single-level TDR) who completed at least 2years of follow-up were included. Clinical and radiological assessments were performed preoperatively and at 1week and 3, 6, 12, and 24months postoperatively. The most common operative level was C5/C6 (49.3%). The differences in blood loss, duration of surgery, and duration of hospitalization were not statistically significant. The Japanese Orthopaedic Association scale, Visual Analog Scale, Neck Disability Index, and Short Form-36 scores improved significantly after surgery in both the DCI and TDR groups (P<0.05), but the differences were not statistically significant at the final follow-up. The rate of occurrence of heterotopic ossification was 22.4% and 28.2% in the DCI and TDR groups, respectively. As an effective non-fusion technique, DCI is a more economical procedure. Further prospective, randomized studies with long-term follow-up periods are needed to determine the long-term effects. PMID:26928156

  4. Arthroplasty register for Germany

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2009-10-01

    Full Text Available Scientific background: The annual number of joint replacement operations in Germany is high. The introduction of an arthroplasty register promises an important contribution to the improvement of the quality of patient’s care. Research questions: The presented report addresses the questions on organization and functioning, benefits and cost-benefits as well as on legal, ethical and social aspects of the arthroplasty registers. Methods: A systematic literature search was conducted in September 2008 in the medical databases MEDLINE, EMBASE etc. and was complemented with a hand search. Documents describing arthroplasty registers and/or their relevance as well as papers on legal, ethical and social aspects of such registers were included in the evaluation. The most important information was extracted and analysed. Results: Data concerning 30 arthroplasty registers in 19 countries as well as one international arthroplasty register were identified. Most of the arthroplasty registers are maintained by national orthopedic societies, others by health authorities or by their cooperation. Mostly, registries are financially supported by governments and rarely by other sources.The participation of the orthopedists in the data collection process of the arthroplasty registry is voluntary in most countries. The consent of the patients is usually required. The unique patient identification is ensured in nearly all registers.Each data set consists of patient and clinic identification numbers, data on diagnosis, the performed intervention, the operation date and implanted prostheses. The use of clinical scores, patient-reported questionnaires and radiological documentation is rare. Methods for data documentation and transfer are paper form, electronic entry as well as scanning of the data using bar codes. The data are mostly being checked for their completeness and validity. Most registers offer results of the data evaluation to the treating orthopedists and

  5. Finger pain

    Science.gov (United States)

    Pain - finger ... Nearly everyone has had finger pain at some time. You may have: Tenderness Burning Stiffness Numbness Tingling Coldness Swelling Change in skin color Redness Many conditions, such ...

  6. Hip replacement - precautions

    Science.gov (United States)

    ... Barker KL, Dewey ME, Sackley CM. Effectiveness of physiotherapy exercise following hip arthroplasty for osteoarthritis: a systematic ... to ask your doctor Hip replacement - discharge Preventing falls - what to ask your doctor Update Date 11/ ...

  7. Postoperative radiologic imaging of joint arthroplasty

    International Nuclear Information System (INIS)

    With increased life expectancy in industrialised countries, improvement of implant design and operative technique, arthroplasty has become a routine procedure. The hip and knee joints are treated by arthroplasty most frequently. Nowadays joint replacement can be performed in many other joints. Radiologic imaging is an important tool for evaluation of the operative results and for detection of early and late complications. In the following article we describe the relevance of different imaging modalities as well as their systematic application in patients with joint arthroplasty. (orig.)

  8. Finger Stiffness

    OpenAIRE

    Oosterhoff, Thijs C.H.; Nota, Sjoerd P. F. T.; Ring, David

    2014-01-01

    Background Finger stiffness varies substantially in patients with hand and upper extremity illness and can be notably more than expected for a given pathophysiology. In prior studies, pain intensity and magnitude of disability consistently correlate with coping strategies such as catastrophic thinking and kinesiophobia, which can be characterized as overprotectiveness. In this retrospective study we address the primary research question whether patients with finger stiffness are more often ov...

  9. Finger Stiffness.

    Science.gov (United States)

    Oosterhoff, Thijs C H; Nota, Sjoerd P F T; Ring, David

    2015-06-01

    Background Finger stiffness varies substantially in patients with hand and upper extremity illness and can be notably more than expected for a given pathophysiology. In prior studies, pain intensity and magnitude of disability consistently correlate with coping strategies such as catastrophic thinking and kinesiophobia, which can be characterized as overprotectiveness. In this retrospective study we address the primary research question whether patients with finger stiffness are more often overprotective when the primary pathology is outside the hand (e.g. distal radius fracture) than when it is located within the hand. Methods In an orthopaedic hand surgery department 160 patients diagnosed with more finger stiffness than expected for a given pathophysiology or time point of recovery between December 2006 and September 2012 were analyzed to compare the proportion of patients characterized as overprotective for differences by site of pathology: (1) inside the hand, (2) outside the hand, and (3) psychiatric etiology (e.g. clenched fist). Results Among 160 subjects with more finger stiffness than expected, 132 (82 %) were characterized as overprotective including 88 of 108 (81 %) with pathology in the hand, 39 of 44 (89 %) with pathology outside the hand, and 5 of 8 (63 %) with psychiatric etiology. These differences were not significant. Conclusions Overprotectiveness is common in patients with more finger stiffness than expected regardless the site and type of primary pathology. It seems worthwhile to recognize and treat maladaptive coping strategies early during recovery to limit impairment, symptoms, and disability. PMID:26078497

  10. Finger pain

    Science.gov (United States)

    ... and bruises Broken finger bones Skier's thumb , an injury to the ligaments in your thumb, such as from a fall ... health care provider. Small fractures or tendon or ligament tears ... have Raynaud's, take steps to protect your hands from the cold.

  11. Mycobacterium smegmatis infection of a prosthetic total knee arthroplasty.

    Science.gov (United States)

    Saffo, Zaid; Ognjan, Anthony

    2016-01-01

    The most common organisms causing prosthetic knee joint infections are staphylococci. However, arthroplasty infections with atypical microbial pathogens, such as Mycobacteria can occur. Due to the rarity of mycobacterial prosthetic joint infections, diagnosis, treatment, and management of these atypical infections represent a clinical challenge. A 71-year old female post-operative day 40 after a left total knee arthroplasty was hospitalized secondary to left knee pain and suspected arthroplasty infection. She had failed outpatient oral antimicrobial treatment for superficial stitch abscess; and outpatient IV/Oral antimicrobials for a clinical postoperative septic bursitis. Ultimately, resection arthroplasty with operative tissue acid fast bacterial cultures demonstrated growth of the Mycobacterium smegmatis group. Post-operatively, she completed a combination course of oral doxycycline and levofloxacin and successfully completed a replacement arthroplasty with clinical and microbial resolution of the infection. To our knowledge, literature review demonstrates three case of knee arthroplasty infection caused by the Mycobacterium smegmatis group. Correspondingly, optimal surgical procedures and antimicrobial management including antimicrobial selection, treatment duration are not well defined. Presently, the best treatment options consists of two step surgical management including prosthesis hardware removal followed by extended antimicrobial therapy, followed by consideration for re-implantation arthroplasty. Our case illustrates importance of considering atypical mycobacterial infections in post-operative arthroplasty infections not responding to traditional surgical manipulations and antimicrobials. For an arthroplasty infection involving the atypical Mycobacterium smegmatis group, two step arthroplasty revision, including arthroplasty resection, with a combination of oral doxycycline and levofloxacin can lead to successful infection resolution, allowing for a

  12. Introduction of total knee arthroplasty in Lithuania

    Science.gov (United States)

    Stucinskas, Justinas; Robertsson, Otto; Wingstrand, Hans

    2009-01-01

    Background and purpose We have previously reported that the first 10 years of hip arthroplasty in Lithuania resulted in a higher cumulative revision rate than that observed in Sweden. We thus compared the corresponding results after introduaction of total knee replacement in Lithuania. Methods The 10-year revision rate for the first 595 primary ScanKnee arthroplasties inserted in Klaipeda, Lithuania, was compared to that for the first 1,280 ScanKnee primary arthroplasties inserted in Sweden. As in the hip replacement study, only patients with osteoarthritis (OA) were included. Primary knee arthroplasties without patellar resurfacing were included, and the endpoint was revision for any reason other than addition of a patellar component. Results We found that the cumulative revision rate was not statistically significantly different between the groups. The revision pattern was different, however, and we observed 24 isolated patellar component additions in Sweden, but none in Klaipeda. Interpretation Contrary to the results of our previous hip arthroplasty study, the cumulative revision rate after total knee arthroplasty was similar in the two groups. This suggests that compared to hip arthroplasty, the outcome of total knee arthroplasty was less dependent on surgical experience. The large difference regarding isolated patellar component additions may be explained by long-term accumulation of severe OA cases in Lithuania. To patients subject to a newly introduced surgical treatment offering great improvement in quality of life, patellofemoral pain may be a minor problem. Furthermore, patellar problems may not have seemed particularly relevant for the surgeons, considering the disability of other patients waiting to be treated. PMID:19297790

  13. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... you're talking about an arthroplasty, their pain relief is fairly rapid and early on. And the ... body and the arm, and have better pain relief. So, with the arthroplasty, it tends to be ...

  14. Artificial Cervical Disc Replacement Improves Mobility

    Medline Plus

    Full Text Available ... a total disc replacement arthroplasty on a young patient who has a herniated disc in her neck. ... way in, it’s, you know, I find that patients have very little pain after surgery. And just ...

  15. Imaging patellar complications after knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Melloni, Pietro [Unitat de Imatge d' Alta Tecnologia, Centre Diagnostic, Corporacio Parc Tauli, Universitat Autonoma de Barcelona, Sabadell (Barcelona) (Spain)], E-mail: pmelloni@cspt.es; Valls, Rafael; Veintemillas, Maite [Unitat de Imatge d' Alta Tecnologia, Centre Diagnostic, Corporacio Parc Tauli, Universitat Autonoma de Barcelona, Sabadell (Barcelona) (Spain)

    2008-03-15

    The purpose of this study is to describe complications affecting the patella in patients with total or partial knee arthroplasty. We respectively analysed plain-film radiographs, as well as ultrasound images when acquired, in a consecutive series of 1272 patients. The mean interval from knee replacement to patellar complications was 5 years and 7 months (range, 5 months to 14 years). The complications described include fracture, instability, dislocation or luxation, necrosis of the patella, infection of the patella, erosion of the patella, patellar impingement on the prosthesis and patellar or quadricipital tendon tear. We discuss the pathological imaging findings in the patella and their differential diagnosis after knee arthroplasty. Patellar complications after knee arthroplasty are uncommon but often potentially serious.

  16. Bicompartmental knee arthroplasty

    OpenAIRE

    Sabatini, Luigi; Giachino, Matteo; Risitano, Salvatore; Atzori, Francesco

    2016-01-01

    Total knee arthroplasty (TKA) is the most worldwide practiced surgery for knee osteoarthritis and its efficacy is mightily described by literature. Concerns about the invasiveness of TKA let the introduction of segmental resurfacing of the joint for younger patients with localized osteoarthritis. Bone stock sparing and ligaments preservation are the essence of both unicompartmental knee arthroplasty (UKA) and bicompartmental knee arthroplasty (BKA). Advantages related to BKA are the respect o...

  17. Total Knee Replacement (Arthroplasty) (Beyond the Basics)

    Science.gov (United States)

    ... demonstrate that 80 to 90 percent of total knees will last between 15 to 20 years, early failures may occur due to a variety of reasons. These include loosening of the implants, infection, fractures of the bone around the implants, and instability. ...

  18. Resurfacing shoulder arthroplasty for the treatment of severe rheumatoid arthritis

    DEFF Research Database (Denmark)

    Voorde, Pia C Ten; Rasmussen, Jeppe V; Olsen, Bo S; Brorson, Stig

    2015-01-01

    outcome was obtained 1-year postoperatively using the Western Ontario Osteoarthritis of the Shoulder index (WOOS), and rates of revision were calculated by checking revisions reported until December 2011. The patient-reported outcome of RHA was compared to that of SHA using regression analysis with......BACKGROUND AND PURPOSE: There is no consensus on which type of shoulder prosthesis should be used in patients with rheumatoid arthritis (RA). We describe patients with RA who were treated with shoulder replacement, regarding patient-reported outcome, prosthesis survival, and causes of revision, and...... we compare outcome after resurfacing hemi-arthroplasty (RHA) and stemmed hemi-arthroplasty (SHA). PATIENTS AND METHODS: We used data from the national Danish Shoulder Arthroplasty Registry and included patients with RA who underwent shoulder arthroplasty in Denmark between 2006 and 2010. Patient-reported...

  19. Reverse Shoulder Arthroplasty for Trauma: When, Where, and How.

    Science.gov (United States)

    Szerlip, Benjamin W; Morris, Brent J; Edwards, T Bradley

    2016-01-01

    Reverse shoulder arthroplasty has become increasingly popular for the treatment of complex shoulder injuries, including proximal humerus fractures and fixed glenohumeral dislocation, in the elderly population. The early to midterm results of reverse shoulder arthroplasty for the treatment of proximal humerus fractures are promising compared with the results of unconstrained humeral head replacement, and patients may have more predictable improvement with less dependence on bone healing and rehabilitation. However, long-term follow-up is needed, and surgeons must be familiar with various complications that are specific to reverse shoulder arthroplasty. To achieve optimal patient outcomes for the management of traumatic shoulder injuries, surgeons must have a comprehensive understanding of the current implant options, indications, and surgical techniques for reverse shoulder arthroplasty. PMID:27049189

  20. Trigger Finger (Stenosing Tenosynovitis)

    Science.gov (United States)

    ... Symptom Picker Hand and Arm Conditions Carpal Tunnel Ganglion Cysts Trigger Finger Arthritis Base of the Thumb See ... Symptom Picker Hand and Arm Conditions Carpal Tunnel Ganglion Cysts Trigger Finger Arthritis Base of the Thumb See ...

  1. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... stability and soft tissue envelope. In the early days of reverse arthroplasty, it used to be said ... often we'll drain these patients for a day to try to prevent hematoma formation, especially in ...

  2. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... to conventional arthroplasty, we often use a subscap soft tissue takedown, rather than an osteotomy because of concerns ... the tendon. We've learned that this anterior soft tissue repair is critical for the stability of the ...

  3. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... in the United States. The indications are a patient with painful arthritis, absent rotator cuff, a less ... reverse arthroplasty is indicated for that type of patient. In a younger patient with an intact cuff, ...

  4. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... reverse shoulder arthroplasty for cuff deficient arthritis. You should be aware that I helped design the system ... the delto- pectoral approach. The three features you should watch for in this video are the things ...

  5. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... that we can take them out at the time of antibiotic stoppage. Another question is, why such ... been with your patients? Well, most of the time when you're talking about an arthroplasty, their ...

  6. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... endo button for secure fixation, as well as #5 Ethibond Mason-Allen sutures around the lesser tuberosity ... hemi arthroplasty, or in an anatomic situation, is 5.3 centimeters from the top of the pectoralis ...

  7. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... a friction bite that if you try to work it around the corner, you can get an ... stability and soft tissue envelope. In the early days of reverse arthroplasty, it used to be said ...

  8. Imaging of hip arthroplasty

    International Nuclear Information System (INIS)

    Hip arthroplasty has become a common and still increasing procedure for the treatment of osteoarthritis, advanced head necrosis, post-inflammatory arthritis or rheumatoid arthritis.Radiography is the most important imaging modality for monitoring the normal, asymptomatic hip arthroplasty. Radiographs are obtained at the end of a surgical treatment, to exclude complications like fracture or component misplacement. In the follow-up radiographs are used for the diagnosis of loosening and infection of the hip arthroplasty as well as soft tissue ossification. Together with the history and clinical information, the analysis of morphological findings allows to find the grade of loosening. MRI has been advocated in the diagnosis of infection, in particular in the localisation of soft tissue involvement.Imaging, especially by radiographs, is used for the evaluation of the normal and complicated follow-up of hip arthroplasty. (orig.)

  9. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... to conventional arthroplasty, we often use a subscap soft tissue takedown, rather than an osteotomy because of ... and anteverted, and we worry about crushing that soft bone of the tuberosity later on. So you ...

  10. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... for sort of common cuff arthroplasty in an elderly thin patient where the head is already rising ... cement this case, because in the typical osteoporotic elderly patient with cuff arthropathy, we would do a ...

  11. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... case of reverse shoulder arthroplasty for cuff deficient arthritis. You should be aware that I helped design ... in the last decade for cuff deficient shoulder arthritis in the United States. The indications are a ...

  12. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... here in New York to bring you a video of a recent case of reverse shoulder arthroplasty ... helped design the system that's shown in this video, so I receive royalties and therefore have a ...

  13. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... residents and do receive compensation for that, as well. Now, reverse shoulder arthroplasty is a new option ... t see the neck of the humerus as well, but on the other hand, you have a ...

  14. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... their arm up but they can't do it actively. And the reverse arthroplasty is indicated for ... those. The advantage of a superior approach is it's especially useful if you've had previous open ...

  15. Imaging of hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T., E-mail: millertt@hss.edu [Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021 (United States)

    2012-12-15

    The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.

  16. Proximal humeral fractures treated with arthroplasty

    Institute of Scientific and Technical Information of China (English)

    QIAN Qi-rong; WU Hai-shan; ZHOU Wei-jiang; LI Xiao-hua; WU Yu-li

    2005-01-01

    Objective: To explore arthroplasty in treating 3- and 4-part fractures of the proximal humerus.Methods: A total of 132 patients with proximal humeral fractures were treated in our hospital from July 1997 to February 2003. According to Neer's classification, the fractures of 45 patients (14 males and 31 females, aged 31-78 years, 56.1 years±7.8 years on an average) belonged to 3- or 4-part fractures (10 patients with 4-part fracture and 35 with 3-part comminuted fracture) and they were treated with shoulder joint arthroplasty. Unipolar prosthesis replacement of the head of humerus was made in 28 cases, while bipolar prosthesis replacement in 2 cases and total shoulder joint replacement in 15 cases. Results: During the follow-up period (range: 12-72 months, mean: 37.3 months±4.1 months), among the 45 patients who suffered from fractures of the proximal humerus and underwent arthroplasty surgery, 44 patients (97.8%) had no postoperative pain and were satisfied with the active range of motion and with the whole treatment results. And radiography showed that the prostheses were at their good position. One patient had postoperative pain because he had so narrow medullary cavity that the humeral prosthesis could not be put deeply enough and the prosthesis head was a little higher over the anatomic level. He did not have good postoperative active range of motion, either. Then he received a review surgery and got satisfied results. Temporary shoulder stiffness was observed in one patient. Manual release of these adhesions improved the shoulder function. No evidence of nonunion of the fracture segments around the humeral prosthesis stem was found. Conclusions: Shoulder arthroplasty is a dependable method to restore the comfort and function of the should joints of the patients with 3- or 4-part fractures of the proximal humerus.

  17. Prevention of infection after knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2010-01-01

    expert opinions.The evidence of the effectiveness of intravenous prophylaxis with antibiotics in knee arthroplasty on a high level of evidence is also missing. The recommendations use evidence on the intravenous antibiotic prophylaxis transferred from RCT in hip arthroplasty to the arthroplasty of all joints including knee replacement. Moreover, no evidence is found for differences in the effectiveness between various antibiotics in knee arthroplasty. The presented report finds strong hints for the effectiveness of antibiotics in cement in addition to the intravenous prophylaxis; however, evidence of the effectiveness may be accepted only for operating rooms without clean-air measures. Discussion: The conclusiveness of the results from non-RCT and from studies for clinically non-relevant endpoints is relatively low. The determined evidence from studies for other clinical indications may be generally transferred to knee replacement operations. Conclusions: No proposal to change the recommendations of the Robert Koch Institute with respect to hygiene interventions and intravenous antibiotic prophylaxis can be made from the presented analysis. Also, no recommendations on the selection of certain antibiotic can be derived from the analysed data. The use of antibiotics in cement in addition to the intravenous prophylaxis may be generally recommended. The cost-effectiveness of different interventions to prevent infections in knee arthroplasty remains unclear. There are no signs for concern regarding any ethical, social and/or legal consequences in the use of interventions to prevent infections in knee arthroplasty.

  18. Heterotopic bone formation following total shoulder arthroplasty

    DEFF Research Database (Denmark)

    Kjaersgaard-Andersen, P.; Frich, Lars Henrik; Sjøbjerg, J.O.;

    1989-01-01

    the glenohumeral and/or the glenoacromial space. There was no correlation between shoulder pain and the development of ossification. Shoulders with grade III heterotopic bone formation had a limited range of active elevation compared with shoulders without or with only a milder lesion. Men and......The incidence and location of heterotopic bone formation following total shoulder arthroplasty were evaluated in 58 Neer Mark-II total shoulder replacements. One year after surgery, 45% had developed some ectopic ossification. In six shoulders (10%) the ossifications roentgenographically bridged...... patients with osteoarthritis of the shoulder joint were significantly disposed to the development of heterotopic bone. Heterotopic bone formation following total shoulder arthroplasty is frequent, but disabling heterotopic ossifications seem to be rare....

  19. Bipolar hip arthroplasty.

    Science.gov (United States)

    Chang, Qing; Liu, Shubing; Guan, Changyong; Yu, Fangyuan; Wu, Shenguang; Jiang, Changliang

    2011-12-01

    Our aim was to compare hip arthroplasty with internal screw fixation in the repair of intertrochanteric fractures in elderly patients with osteoporosis. Of 112 included patient, 70 (81.81 ± 4.88 years) received hip arthroplasty with a prosthesis specially designed for intertrochanteric fractures, and 42 (83.46 ± 5.11 years) underwent plate-screw fixation. The hip arthroplasty group had significantly longer operation time, intraoperative blood loss, and total volume of blood transfused but had shorter time to beginning weight-bearing (5.94 ± 2.76 vs 23.68 ± 22.01 days) and higher postoperative Harris hip score (91.37 ± 4.80 vs 86.14 ± 5.46). In the arthroplasty group, there were 2 dislocations; and in the plate-screw fixation group, there were 5 internal fixation failures. Hip arthroplasty is preferable to internal fixation in elderly patients (age >80 years) with osteoporosis. PMID:21530148

  20. Bicompartmental knee arthroplasty

    Science.gov (United States)

    Giachino, Matteo; Risitano, Salvatore; Atzori, Francesco

    2016-01-01

    Total knee arthroplasty (TKA) is the most worldwide practiced surgery for knee osteoarthritis and its efficacy is mightily described by literature. Concerns about the invasiveness of TKA let the introduction of segmental resurfacing of the joint for younger patients with localized osteoarthritis. Bone stock sparing and ligaments preservation are the essence of both unicompartmental knee arthroplasty (UKA) and bicompartmental knee arthroplasty (BKA). Advantages related to BKA are the respect of knee biomechanics, lower complications rates, shorter hospital stay, faster rehabilitation. Moreover, in case of failure of the first implant the conversion to TKA is undemanding and can be compared to a standard prosthesis. Our experience suggest that BKA is a reliable technique in selected cases and especially younger people with higher functional requests can favourably profit from it. Although those results are encouraging, we still need further prospective, randomized, long-term studies to finally assess BKA indications and outcomes. PMID:26855941

  1. Bicompartmental knee arthroplasty.

    Science.gov (United States)

    Sabatini, Luigi; Giachino, Matteo; Risitano, Salvatore; Atzori, Francesco

    2016-01-01

    Total knee arthroplasty (TKA) is the most worldwide practiced surgery for knee osteoarthritis and its efficacy is mightily described by literature. Concerns about the invasiveness of TKA let the introduction of segmental resurfacing of the joint for younger patients with localized osteoarthritis. Bone stock sparing and ligaments preservation are the essence of both unicompartmental knee arthroplasty (UKA) and bicompartmental knee arthroplasty (BKA). Advantages related to BKA are the respect of knee biomechanics, lower complications rates, shorter hospital stay, faster rehabilitation. Moreover, in case of failure of the first implant the conversion to TKA is undemanding and can be compared to a standard prosthesis. Our experience suggest that BKA is a reliable technique in selected cases and especially younger people with higher functional requests can favourably profit from it. Although those results are encouraging, we still need further prospective, randomized, long-term studies to finally assess BKA indications and outcomes. PMID:26855941

  2. ELIGIBILITY FOR THE HIP-RESURFACING ARTHROPLASTY PROCEDURE: AN EVALUATION ON 592 HIPS

    Science.gov (United States)

    Queiroz, Roberto Dantas; Faria, Rafael Salomon Silva; Duarte, David Marcelo; Takano, Marcelo Itiro; Sugiyama, Mauricio Morita

    2015-01-01

    Objective: To investigate the percentage of ideal patients who would be eligible for hip-resurfacing surgery at a reference service for hip arthroplasty. Methods: Out of all the cases of hip arthroplasty operated at Hospital do Servidor Público Estadual de São Paulo (HSPE) between January 2009 and December 2010, we assessed a total of 592 procedures that would fit the criteria for indication for resurfacing arthroplasty, after clinical and radiological evaluation according to the criteria established by the Food and Drug Administration (FDA) and by Seyler et al. Results: Among the total number of hip replacement arthroplasty cases, 5.74% of the patients were eligible. Among the patients who underwent primary arthroplasty, we found that 8.23% presented ideal conditions for this procedure. Conclusion: The study demonstrated that this type of surgery still has a limited role among hip surgery methods. PMID:27047851

  3. Rolling friction robot fingers

    Science.gov (United States)

    Vranish, John M.

    1992-06-01

    A low friction, object guidance, and gripping finger device for a robotic end effector on a robotic arm is disclosed, having a pair of robotic fingers each having a finger shaft slideably located on a gripper housing attached to the end effector. Each of the robotic fingers has a roller housing attached to the finger shaft. The roller housing has a ball bearing mounted centering roller located at the center, and a pair of ball bearing mounted clamping rollers located on either side of the centering roller. The object has a recess to engage the centering roller and a number of seating ramps for engaging the clamping rollers. The centering roller acts to position and hold the object symmetrically about the centering roller with respect to the X axis and the clamping rollers act to position and hold the object with respect to the Y and Z axis.

  4. Multiple Fingers - One Gestalt.

    Science.gov (United States)

    Lezkan, Alexandra; Manuel, Steven G; Colgate, J Edward; Klatzky, Roberta L; Peshkin, Michael A; Drewing, Knut

    2016-01-01

    The Gestalt theory of perception offered principles by which distributed visual sensations are combined into a structured experience ("Gestalt"). We demonstrate conditions whereby haptic sensations at two fingertips are integrated in the perception of a single object. When virtual bumps were presented simultaneously to the right hand's thumb and index finger during lateral arm movements, participants reported perceiving a single bump. A discrimination task measured the bump's perceived location and perceptual reliability (assessed by differential thresholds) for four finger configurations, which varied in their adherence to the Gestalt principles of proximity (small versus large finger separation) and synchrony (virtual spring to link movements of the two fingers versus no spring). According to models of integration, reliability should increase with the degree to which multi-finger cues integrate into a unified percept. Differential thresholds were smaller in the virtual-spring condition (synchrony) than when fingers were unlinked. Additionally, in the condition with reduced synchrony, greater proximity led to lower differential thresholds. Thus, with greater adherence to Gestalt principles, thresholds approached values predicted for optimal integration. We conclude that the Gestalt principles of synchrony and proximity apply to haptic perception of surface properties and that these principles can interact to promote multi-finger integration. PMID:26863671

  5. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available Reverse Shoulder Arthroplasty Zimmer, Inc. New York City, New York March 17, 2010 Welcome to this OR Live presentation, brought to you by Zimmer. Hi. I'm ... my partner, Brad Parsons. We're here in New York to bring you a video of a ...

  6. Shoulder arthroplasty. Part 1: Prosthesis terminology and classification

    Energy Technology Data Exchange (ETDEWEB)

    Sheridan, B.D., E-mail: bdsheridan@hotmail.com [Department of Orthopaedic Surgery, Bristol Royal Infirmary, Bristol (United Kingdom); Ahearn, N.; Tasker, A.; Wakeley, C.; Sarangi, P. [Department of Orthopaedic Surgery, Bristol Royal Infirmary, Bristol (United Kingdom)

    2012-07-15

    Shoulder arthroplasty is the third most common joint replacement procedure in the UK, and there are a number of different implant options available to surgeons to treat a variety of shoulder disorders. With an increasing burden placed on clinical follow-up, more patients are remaining under the care of their general practitioners and musculoskeletal triage assessment services and are not necessarily being seen by specialists. Referrals to orthopaedic specialists are therefore often prompted by radiological reports describing evidence of implant failure. This article is the first of two reviews on shoulder arthroplasty, concentrating on implant features and the indications for their use. The second article will address the modes of failure of shoulder arthroplasty and describe the relevant associated radiological features.

  7. Shoulder arthroplasty. Part 1: Prosthesis terminology and classification

    International Nuclear Information System (INIS)

    Shoulder arthroplasty is the third most common joint replacement procedure in the UK, and there are a number of different implant options available to surgeons to treat a variety of shoulder disorders. With an increasing burden placed on clinical follow-up, more patients are remaining under the care of their general practitioners and musculoskeletal triage assessment services and are not necessarily being seen by specialists. Referrals to orthopaedic specialists are therefore often prompted by radiological reports describing evidence of implant failure. This article is the first of two reviews on shoulder arthroplasty, concentrating on implant features and the indications for their use. The second article will address the modes of failure of shoulder arthroplasty and describe the relevant associated radiological features.

  8. Postoperative radiologic imaging of joint arthroplasty; Postoperative radiologische Beurteilung von Gelenkendoprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Aldinger, P.R. [Abt. Orthopaedie I, Orthopaedische Universitaetsklinik Heidelberg (Germany); Ludwig, K. [Sektion Diagnostische Radiologie, Orthopaedische Universitaetsklinik Heidelberg (Germany)

    2006-06-15

    With increased life expectancy in industrialised countries, improvement of implant design and operative technique, arthroplasty has become a routine procedure. The hip and knee joints are treated by arthroplasty most frequently. Nowadays joint replacement can be performed in many other joints. Radiologic imaging is an important tool for evaluation of the operative results and for detection of early and late complications. In the following article we describe the relevance of different imaging modalities as well as their systematic application in patients with joint arthroplasty. (orig.)

  9. Fingers that change color

    Science.gov (United States)

    ... cause fingers or toes to change color: Buerger disease Chilblains. Painful inflammation of small blood vessels. Cryoglobulinemia Frostbite Necrotizing vasculitis Peripheral artery disease Raynaud phenomenon. Sudden change in the ...

  10. Early clinical effect of patellar replacement on anterior knee pain in patients with knee osteoarthritis after total knee arthroplasty%全膝关节置换术中髌骨置换对骨性关节炎患者早期疗效及膝前痛的影响

    Institute of Scientific and Technical Information of China (English)

    朱伟民; 唐本森; 张涛; 周广福; 田晓滨

    2015-01-01

    目的:探讨全膝关节置换术中是否进行髌骨置换对骨性关节炎患者的临床疗效及术后疼痛的影响。方法笔者采用随机数字表法将骨科2011年5月~2013年7月收治的93例行人工全膝关节置换术患者分为髌骨置换组43例和未置换组50例,比较两组患者治疗前与治疗后不同时间的相关指标变化差异。结果术前髌骨置换组与非置换组的膝关节KSS(美国膝关节协会)评分、Feller评分差异不显著( P>0.05);术后第3、6、12个月髌骨置换组膝关节KSS评分、Feller评分显著高于非置换组(P<0.05);术前髌骨置换组与非置换组的膝关节视觉模拟评分(VAS)差异不显著(P>0.05);术后第3、6、12个月髌骨置换组膝关节VAS评分显著低于非置换组(P<0.05);两组患者术前、术后的胫股角,髌韧带比值,关节活动度ROM屈、伸值在两组间比较差异均不显著( P>0.05);术后第12个月两组患者的胫股角、髌韧带比值,关节活动度ROM屈、伸值较治疗前均显著好转( P<0.05)。结论全膝关节置换术中进行髌骨置换对改善膝关节功能评分、髌骨评分、术后疼痛评分均有显著的效果。%Objective To discuss the clinical efficacy and postoperative pain of patellar replacement in pa-tients with osteoarthritis in total knee arthroplasty.Methods A total of 93 cases with total knee arthroplasty in our hospital from May 2011 to Jul.2013 were randomly selected and divided into replacement group( n=43) and non-replacement group( n=50) by the stochastic indicator method.The differences of related indicators at different time points between the two groups were compared.Results The differences of KSS knee score and Feller score be-tween the preoperative replacement group and non-replacement group were not significant(P>0.05);3,6 and 12 months after the surgery,the KSS knee score and Feller score of the replacement

  11. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... the head is already rising up under the skin, and it's very natural to just bring it ... see we're making an incision in the skin creases. My long finger is on the coracoid, ...

  12. Genome Engineering With Zinc-Finger Nucleases

    OpenAIRE

    Carroll, Dana

    2011-01-01

    Zinc-finger nucleases (ZFNs) are targetable DNA cleavage reagents that have been adopted as gene-targeting tools. ZFN-induced double-strand breaks are subject to cellular DNA repair processes that lead to both targeted mutagenesis and targeted gene replacement at remarkably high frequencies. This article briefly reviews the history of ZFN development and summarizes applications that have been made to genome editing in many different organisms and situations. Considerable progress has been mad...

  13. The Danish Shoulder Arthroplasty Registry

    DEFF Research Database (Denmark)

    Rasmussen, Jeppe; Jakobsen, John; Brorson, Stig;

    2012-01-01

    The Danish Shoulder Arthroplasty Registry (DSR) was established in 2004. Data are reported electronically by the surgeons. Patient-reported outcome is collected 10-14 months postoperatively using the Western Ontario osteoarthritis of the shoulder index (WOOS). 2,137 primary shoulder arthroplasties...

  14. Narrow fingers in the Saffman-Taylor instability

    Science.gov (United States)

    Couder, Y.; Gerard, N.; Rabaud, M.

    1986-12-01

    Saffman-Taylor fingers with a relative width much smaller than the classical limit lambda = 0.5 are found when a small isolated bubble is located at their tip. These solutions are members of a family found by Saffman and Taylor (1958) neglecting superficial tension. Recent theories have shown that when capillary forces are taken into account an unphysical cusplike singularity would appear at the tip of all the fingers with lambda less than 0.5. Conversely, here the replacement of the tip by a small bubble makes these solutions possible. At large velocity these fingers show dendritic instability.

  15. The influence of knee function to patella replacement and patellar plasty in totle knee arthroplasty%全膝关节置换术中髌骨置换与髌骨成形对膝关节功能的影响

    Institute of Scientific and Technical Information of China (English)

    杨小春; 郝邵文; 马晓军; 金群华

    2013-01-01

    Objective To investigate the effects on knee function between patella plasty and patellar replacement in total knee arthroplasty.Methods From August 2010 to November 2010,48 patients (69 knees) of osteoarthritis performed TKA were covered in this study.All the patients were randomly assigned to the following two groups:one group contained 24 patients (34 knees) performed patella plasty,and the other group contained other 24 patients (35 knees) performed patellar replacement.There was no significant difference between the two groups in age,weight,height,BMI,patellar score and the American Knee Society Score (KSS).Every patient was followed up for 6 weeks,3 months,6 months,one year,and two years.All the results,which were used to compare the difference between the two groups,in KSS knee score,knee function score,patellar score,the incidence of anterior knee pain,and imaging findings.Results In this clinical study,20 patients (30 knees) in patellar replacement group and 20 patients (29 knees) in patella plasty group were followed up.No significant difference was found in the postoperative KSS knee score between 2 groups at each time point.The KSS knee function score in replacement group was significantly higher than that in arthroplasty group at 6,12 and 24 months after operation.The incidence of anterior knee pain after the surgery in replacement group was significant different from the plasty group at every time point after operation.There was no significant difference in tibiofemoral angle,patellar ligament ratio,patellar tilt angle,congruence angle and lateral patellar displacement between two groups at last follow-up.Conclusion Total knee arthroplasty with patella replacement can improve both knee function and patella function,and reduce the incidence of postoperative anterior knee pain.%目的 探讨髌骨置换与髌骨成形对全膝关节置换术后膝关节功能的影响.方法 对2010年8月至11月拟行全膝关节置换术的48例(69膝)膝关节骨

  16. Replantation (Finger, Hand, or Arm)

    Science.gov (United States)

    ... Symptom Picker Hand and Arm Conditions Carpal Tunnel Ganglion Cysts Trigger Finger Arthritis Base of the Thumb See ... Symptom Picker Hand and Arm Conditions Carpal Tunnel Ganglion Cysts Trigger Finger Arthritis Base of the Thumb See ...

  17. Factors Influencing Range of Motion after Total Knee Arthroplasty

    OpenAIRE

    H Farahini; Moghtadaei, M; Bagheri, A; Akbarian, E

    2012-01-01

    Background The range of motion after a total knee arthroplasty is an important clinical outcome affecting the life of the patient. The aim of this study was to determine the most important factors influencing the postoperative knee flexion in Tehran, Iran. Methods Between July 2007 and January 2009, on 95 cases of total knee joint replacement (89 patients), who were followed for 1 year postoperatively, the risk factors were assessed. Patient demographics (sex, age, body mass index, previous s...

  18. Knee Muscles Power Evolution in Patients with Total Knee Arthroplasty

    OpenAIRE

    Ileana Monica BORDA; IRSAY Laszlo; Rodica UNGUR; Viorela CIORTEA; Ioan ONAC; Alina SUSMAN; Liviu POP

    2012-01-01

    Purpose: To measure changes in muscle power from before to 6 months after total knee arthroplasty and to compare outcomes with those from a control group of healthy adults. Material and Methods: 26 patients who underwent a total knee replacement were compared with 12 healthy age-matched adults in a prospective cohort study. Patients’ assessment was performed preoperatively, as well as at 1, 2 and 6 months postoperatively, by the isokinetic method. Healthy adults were assessed once by the same...

  19. Spiral viscous fingering.

    Science.gov (United States)

    Nagatsu, Yuichiro; Hayashi, Atsushi; Kato, Yoshihito; Tada, Yutaka

    2006-11-01

    When a less-viscous fluid displaces a more-viscous fluid in a radial Hele-Shaw cell, viscous fingering pattern is believed to develop in a radial direction. We performed experiments on viscous fingering in a radial Hele-Shaw cell when a polymer solution, a sodium polyacrylate (SPA) solution is used as the more-viscous fluid and the trivalent iron (Fe^3+) solution is as the less-viscous fluid. The experiment was done by varying the concentration of Fe^3+, cFe3+. We have found that viscous fingering pattern develops spirally when cFe3+ is larger than a threshold value, while the pattern develops in a radial direction for small cFe3+. We confirmed from different experiments that an instantaneous chemical reaction takes place between SPA solution and Fe^3+ solution. The chemical reaction produces precipitation and significantly reduces the viscosity of the SPA solution. The quantity of the precipitation is increased with cFe3+. We will make a discussion on the relationship between the formation of spiral viscous fingering and the chemical reaction taking place between the two fluids.

  20. X-Ray Exam: Finger

    Science.gov (United States)

    ... Tropical Delight: Melon Smoothie Pregnant? Your Baby's Growth X-Ray Exam: Finger KidsHealth > For Parents > X-Ray Exam: Finger Print A A A Text Size ... español Radiografía: dedo What It Is A finger X-ray is a safe and painless test that uses ...

  1. Chronic infections in hip arthroplasties

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Thomsen, Reimar W; Søballe, Kjeld

    2012-01-01

    Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two-stage revisi......Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two......-stage revisions for chronic infection in hip arthroplasties....

  2. Minimally invasive total hip arthroplasty with the anterior approach

    Directory of Open Access Journals (Sweden)

    Bal B

    2008-01-01

    Full Text Available Background: Total hip athroplasty with the anterior surgical approach is advised because the dissection is entirely within intermuscular planes. In this report we describe a minimally invasive technique of anterior total hip arthroplasty, with the early outcomes. Materials and Methods: The technique of minimally invasive total hip arthroplasty with anterior approach (Smith-Petersen is described. We reviewed data on 100 consecutive patients who underwent anterior total hip arthroplasty with uncemented components. Mean patient age was 61 years (range 33-91. Mean patience BMI 29.8 (range 18.1-51.8. Results: Minumum follow up duration is 10 months. The mean duration of surgery was 53 min (range 34-87 with mean blood loss 185 cc (range 65-630, and the mean incision length was 10.4 cm. Clinical and radiographic outcomes were similar to historical outcomes of standard total hip arthroplasty. Conclusions: With proper surgeon training, minimally invasive total hip replacement with the anterior surgical interval is safe and efficacious.

  3. The Research of Artificial Cervical Disc Replacement

    Institute of Scientific and Technical Information of China (English)

    Zhao Zhua; Qiang Shenb

    2008-01-01

    Cervical arthroplasty after anterior decompression with insertion of a prosthetic total disc replacement has been suggested as an alternate to anterior cervical fusion. It develops quickly during recent years. Currently there are several cervical arthroplasty devices. Each device varies in terms of materials, range of motion and constraint. Early studies suggest that in the short term, the complication rate and efficacy is no worse than fusion surgery. Long-term results have not yet been reported. This review examines the current prostheses as well as discussing issues regarding indications and technique. It is hoped that an improvement of cervical arthroplasty occurs in terms of materials and design as spinal surgeons enter a new dines of the management of cervical spine disease.

  4. Souter arthroplasty for elbows with severe destruction.

    Science.gov (United States)

    Ikävalko, Mikko; Belt, Eero A; Kautiainen, Hannu; Lehto, Matti U K

    2004-04-01

    One hundred fifty-eight primary Souter elbow arthroplasties were done on 134 patients (121 women) with severe joint destruction (Larsen Grade 5) or large bone defects or both. Joint replacement operations were done at our institution from 1985-1997. The study group comprised 156 joints in 132 patients with rheumatoid arthritis or other variants of chronic inflammatory joint disease, one in a patient with osteoarthritis, and one patient with posttraumatic arthrosis. The mean age of the patients at the time of surgery was 57 years (range, 26-81 years) and the mean disease duration was 27 years (tinge, 2-70 years). Radiographically, severe bone defects were detected in 100 humeri and 134 ulnas. Retentive (snap-fit) ulnar components were implanted in 110 joints, and bone grafts were used on 26 humeri and 14 ulnas. Major complications led to five early and 16 late reoperations in 19 patients. Four reoperations were done because of dislocation and eight because of aseptic loosening. One reoperation was done because of early infection and five were done because of late infection. One patient had reoperation because of superficial infection in the bursa olecrani and one triceps tendon rupture also was repaired. One patient had wound repair because of marginal necrosis. In the survival analysis, the cumulative success rate without revision for aseptic loosening at 5 years followup was 97%. Despite the demanding nature of these arthroplasties, the primary results are encouraging. Technically, it is possible to do elbow replacement, even on elbows where the humeral condyles or olecranon or both are missing, if there is sufficient bone left on the diaphyseal areas for primary stem fixation. However, in these extreme cases, the poor general condition of the patient or the difficult soft tissue problems in the elbow region may prove to be a contraindication for joint replacement. PMID:15123937

  5. The Cruciate Ligaments in Total Knee Arthroplasty.

    Science.gov (United States)

    Parcells, Bertrand W; Tria, Alfred J

    2016-01-01

    The early knee replacements were hinge designs that ignored the ligaments of the knee and resurfaced the joint, allowing freedom of motion in a single plane. Advances in implant fixation paved the way for modern designs, including the posterior-stabilized (PS) total knee arthroplasty (TKA) that sacrifices both cruciate ligaments while substituting for the posterior cruciate ligament (PCL), and the cruciate-retaining (CR) TKA designs that sacrifice the anterior cruciate ligament but retain the PCL. The early bicruciate retaining (BCR) TKA designs suffered from loosening and early failures. Townley and Cartier designed BCR knees that had better clinical results but the surgical techniques were challenging.Kinematic studies suggest that normal motion relies on preservation of both cruciate ligaments. Unicompartmental knee arthroplasty retains all knee ligaments and closely matches normal motion, while PS and CR TKA deviate further from normal. The 15% to 20% dissatisfaction rate with current TKA has renewed interest in the BCR design. Replication of normal knee kinematics and proprioception may address some of the dissatisfaction. PMID:27327919

  6. Minimally Invasive Total Knee Arthroplasty

    Medline Plus

    Full Text Available ... Institute. We're going to be doing an MIS total knee arthroplasty with the Zimmer mobile bearing ... this point. And there is many recipes for MIS knee surgery as there are surgeons. What’s kind ...

  7. Directed evolution of improved zinc finger methyltransferases.

    Directory of Open Access Journals (Sweden)

    Brian Chaikind

    Full Text Available The ability to target DNA methylation toward a single, user-designated CpG site in vivo may have wide applicability for basic biological and biomedical research. A tool for targeting methylation toward single sites could be used to study the effects of individual methylation events on transcription, protein recruitment to DNA, and the dynamics of such epigenetic alterations. Although various tools for directing methylation to promoters exist, none offers the ability to localize methylation solely to a single CpG site. In our ongoing research to create such a tool, we have pursued a strategy employing artificially bifurcated DNA methyltransferases; each methyltransferase fragment is fused to zinc finger proteins with affinity for sequences flanking a targeted CpG site for methylation. We sought to improve the targeting of these enzymes by reducing the methyltransferase activity at non-targeted sites while maintaining high levels of activity at a targeted site. Here we demonstrate an in vitro directed evolution selection strategy to improve methyltransferase specificity and use it to optimize an engineered zinc finger methyltransferase derived from M.SssI. The unusual restriction enzyme McrBC is a key component of this strategy and is used to select against methyltransferases that methylate multiple sites on a plasmid. This strategy allowed us to quickly identify mutants with high levels of methylation at the target site (up to ∼80% and nearly unobservable levels of methylation at a off-target sites (<1%, as assessed in E. coli. We also demonstrate that replacing the zinc finger domains with new zinc fingers redirects the methylation to a new target CpG site flanked by the corresponding zinc finger binding sequences.

  8. Safe Finger Tourniquet-Ideas.

    Science.gov (United States)

    Wei, Lin-Gwei; Chen, Chieh-Feng; Hwang, Chun-Yuan; Chang, Chiung-Wen; Chiu, Wen-Kuan; Li, Chun-Chang; Wang, Hsian-Jenn

    2016-03-01

    Tourniquets are often needed for optimized phalangeal surgeries. However, few surgeons forget to remove them and caused ischemic injuries. We have a modified method to create a safe finger tourniquet for short duration finger surgeries, which can avoid such tragedy. It is done by donning a glove, cutting the tip of the glove over the finger of interest, and rolling the glove finger to the base. From 2010 to 2013, approximately 54 patients underwent digital surgical procedures with our safe finger tourniquet. Because the glove cannot be forgotten to be removed, the tourniquet must be released and removed. This is a simple and efficient way to apply a safe finger tourniquet by using hand rubber glove for a short-term bloodless finger surgery and can achieve an excellent surgical result. PMID:26855166

  9. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... replacement. There are two basic approaches you can use for reverse shoulder replacement. The standard delto-pectoral ... surgery or a deltoid defect because you can use the same incision and repair any deltoid defects ...

  10. Influence of navigation system updates on total knee arthroplasty

    OpenAIRE

    Inui, Hiroshi; Taketomi, Shuji; Nakamura, Kensuke; Takei, Seira; Takeda, Hideki; Tanaka, Sakae; NAKAGAWA, TAKUMI

    2013-01-01

    Background The purpose of this study was to evaluate the influence of image-free computer-assisted navigation system update on outcome in total knee arthroplasty. Methods Thirty-three knees were replaced using the Stryker 3.1 image-free navigation system and 49 knees were replaced using the Stryker 4.0 system. One surgeon took part in all procedures as chief surgeon or first assistant. All patients received the Stryker Scopio NRG CR total knee prosthesis. We compared the accuracy of component...

  11. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3210 Section 888.3210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/metal constrained cemented prosthesis. (a) Identification. A finger joint metal/metal constrained cemented prosthesis is a device intended to be implanted to replace a metacarpophalangeal (finger)...

  12. Single active finger IPMC microgripper

    International Nuclear Information System (INIS)

    This paper presents a new design for a single active finger ionic polymer metal composite (IPMC) microgripper. This design has one stationary finger and one actuating finger. The gripper is tested in comparison with a two fingered gripper (2FG) on its ability to perform pick and place operations. The grippers each use IPMC strips in three widths: 1.25 mm, 2.5 mm and 5.0 mm. The single fingered gripper shows success rates of 86.2%, 89.2%, and 75% respectively versus 78.5%, 93.9% and 75% for a 2FG. The single fingered gripper performance is nearly equivalent to that of a 2FG. Even though a single finger produces half the force, its ability to carry objects is as good as or better than a 2FG. In addition, the stationary finger is considerably stiffer than an active IPMC finger, which helps in positional accuracy. Using half the IPMC, the single fingered gripper is the economical choice. (paper)

  13. Viscous fingering patterns in ferrofluids

    OpenAIRE

    Widom, Michael; Miranda, Jose A.

    1998-01-01

    Viscous fingering occurs in the flow of two immiscible, viscous fluids between the plates of a Hele-Shaw cell. Due to pressure gradients or gravity, the initially planar interface separating the two fluids undergoes a Saffman-Taylor instability and develops finger-like structures. When one of the fluids is a ferrofluid and a perpendicular magnetic field is applied, the labyrinthine instability supplements the usual viscous fingering instability, resulting in visually striking, complex pattern...

  14. Finger Forces in Clarinet Playing

    Science.gov (United States)

    Hofmann, Alex; Goebl, Werner

    2016-01-01

    Clarinettists close and open multiple tone holes to alter the pitch of the tones. Their fingering technique must be fast, precise, and coordinated with the tongue articulation. In this empirical study, finger force profiles and tongue techniques of clarinet students (N = 17) and professional clarinettists (N = 6) were investigated under controlled performance conditions. First, in an expressive-performance task, eight selected excerpts from the first Weber Concerto were performed. These excerpts were chosen to fit in a 2 × 2 × 2 design (register: low–high; tempo: slow–fast, dynamics: soft–loud). There was an additional condition controlled by the experimenter, which determined the expression levels (low–high) of the performers. Second, a technical-exercise task, an isochronous 23-tone melody was designed that required different effectors to produce the sequence (finger-only, tongue-only, combined tongue-finger actions). The melody was performed in three tempo conditions (slow, medium, fast) in a synchronization-continuation paradigm. Participants played on a sensor-equipped Viennese clarinet, which tracked finger forces and reed oscillations simultaneously. From the data, average finger force (Fmean) and peak force (Fmax) were calculated. The overall finger forces were low (Fmean = 1.17 N, Fmax = 3.05 N) compared to those on other musical instruments (e.g., guitar). Participants applied the largest finger forces during the high expression level performance conditions (Fmean = 1.21 N). For the technical exercise task, timing and articulation information were extracted from the reed signal. Here, the timing precision of the fingers deteriorated the timing precision of the tongue for combined tongue-finger actions, especially for faster tempi. Although individual finger force profiles were overlapping, the group of professional players applied less finger force overall (Fmean = 0.54 N). Such sensor instruments provide useful insights into player

  15. Robotic Finger Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bridgwater, Lyndon (Inventor); Diftler, Myron A. (Inventor); Linn, Douglas Martin (Inventor); Platt, Robert J., Jr. (Inventor); Hargrave, Brian (Inventor); Askew, Scott R. (Inventor); Valvo, Michael C. (Inventor)

    2014-01-01

    A robotic hand includes a finger with first, second, and third phalanges. A first joint rotatably connects the first phalange to a base structure. A second joint rotatably connects the first phalange to the second phalange. A third joint rotatably connects the third phalange to the second phalange. The second joint and the third joint are kinematically linked such that the position of the third phalange with respect to the second phalange is determined by the position of the second phalange with respect to the first phalange.

  16. Complications Related to Metal-on-Metal Articulation in Trapeziometacarpal Joint Total Joint Arthroplasty

    DEFF Research Database (Denmark)

    Frølich, Christina; Hansen, Torben Bæk

    2015-01-01

    Adverse reactions to metal-on-metal (MoM) prostheses are well known from total hip joint resurfacing arthroplasty with elevated serum chrome or cobalt, pain and pseudo tumor formation. It may, however, also be seen after total joint replacement of the trapeziometacarpal joint using MoM articulation...

  17. Soft tissue balancing in total shoulder replacement

    OpenAIRE

    Mueller, Maike; Hoy, Gregory

    2014-01-01

    Total shoulder arthroplasty is now capable of recreating near anatomic reproduction of native bony shoulder anatomy, but the function and longevity of anatomic shoulder replacement is dependent on a competent soft tissue envelope and adequate motoring of all musculo-tendinous units about the shoulder. Balancing the soft tissues requires understanding of the anatomy and pathology, as well as technical skills. The advent of reverse shoulder biomechanics has brought with it special requirements ...

  18. A PROSPECTIVE STUDY OF PHARMACOLOGICAL PROPHYLAXIS OF DEEP VEIN THROMBOSIS IN ARTHROPLASTY

    OpenAIRE

    Gopalakrishna; Diwakar; Manjunath; Annappaswamy

    2014-01-01

    BACKGROUND: Joint replacement surgeries were associated with significant risk of deep vein thrombosis further leading to complications like pulmonary embolism, a need for prevention of complications by using DVT prophylaxis among Indian patients. OBJECTIVE: The risk of DVT & pulmonary embolism following joint replacement surgeries were largely studied in western countries whereas the same following arthroplasty was studied to a lesser extent in India. To find out the effic...

  19. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... March 17, 2010 Welcome to this OR Live presentation, brought to you by Zimmer. Hi. I'm ... learn about shoulder replacement. You can do a skills course at the learning center that the academy ...

  20. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... replacement. The standard delto-pectoral approach, or the superior approach, which we're going to show you ... shaft to remove those. The advantage of a superior approach is it's especially useful if you've ...

  1. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... with an intact cuff, we would consider a traditional shoulder replacement. There are two basic approaches you ... less limited with the superior reverse versus the traditional. And I assume the question means the approach: ...

  2. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... is tight, in terms of tension? What's your thinking on that? Well, when we originally started doing ... learn about shoulder replacement. You can do a skills course at the learning center that the academy ...

  3. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... you can use for reverse shoulder replacement. The standard delto-pectoral approach, or the superior approach, which ... that are different between a reverse and a standard total is, first of all, we don't ...

  4. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... demanding occupation or lifestyle and usually over the age of 70, and ideally who has pseudo paralysis ... conventional replacement. So this is a 72-year-old patient with cuff deficient arthritis. She had had ...

  5. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... dislocations, although it's also reported to have a higher rate of getting the components in not perfect ... about infection and other things. There is a higher rate of infection with reverse replacement, probably because ...

  6. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... learned that this anterior soft tissue repair is critical for the stability of the implant. And certainly, ... learn about shoulder replacement. You can do a skills course at the learning center that the academy ...

  7. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... 20 degrees of retroversion, rather than 20 to 40 degrees, as in a conventional replacement. So this ... good bone. We like to have at least 40 on the inferior screw and at least 30 ...

  8. Reverse Shoulder Arthroplasty

    Medline Plus

    Full Text Available ... will be in when they come out of anesthesia. You should know that we do most of ... joint replacements under regional block without using general anesthesia. Although if the patient's older or there's a ...

  9. Covering the Dorsal Finger Defect with Reverse Cross Finger Flap

    Directory of Open Access Journals (Sweden)

    Kaan Gurbuz

    2014-12-01

    Full Text Available Reconstruction of finger extensor zone defects with or without tendon gaps still remains a challenge for surgeons. Although surgical treatments may differ, and range from the use of local, regional, to free flaps, the outcomes for all cases are not satisfactory. In this case report, we present a case of a 3rd finger extensor side crush injury including a defect of Dd (Digit Dorsal 1, Dd2 and Dd3 defects of extensor zones with tendon gap. Tendon gap was reconstructed using m. palmaris longus tendon graft and the defect was covered with reversed cross-finger flap (random pattern with good cosmetic and excellent functional results.

  10. Outcome of total knee arthroplasty with insall burstein-11 prosthesis

    International Nuclear Information System (INIS)

    Patients with severe degenerative knee joint disease often require knee arthroplasty to reduce pain, improve stability and restore function. Insall Burstein II prosthesis is posteriorly stabilized condylar prosthesis, which provide posterior cruciate ligament substitution. It was designed to improve range of motion, stair climbing ability and to prevent posterior subluxation. Evaluate the functional outcome of total knee arthroplasty with IB II prosthesis and Evaluate the alignment of prosthetic components by radiological parameters and its correlation with functional outcome. Sixty knees of sixty patients were replaced by using Insall Burstein II prosthesis. Postoperative radiographs were evaluated for alignment of knee and prosthetic components by criteria selected from knee society roentogenographic evaluation system. Functional outcome was evaluated by rationale of knee society knee rating system. Prosthetic component was aligned in 93% and mal-alignment in 7% of the cases. There was significant improvement in functions core from mean score 33.83 +-15.5 to 59.5+-17.7 and knee score from 37 +- 12.5 to 76.4 +-2.2. Postoperative functional score was found correlated with alignment significantly. Conclusion: Total knee arthroplasty with I-B-II prosthesis is a safe durable and predictable procedure with proper surgical technique and expertise good alignment and satisfactory functional out come can be achieved. (author)

  11. Steadily translating parabolic dissolution fingers

    CERN Document Server

    Kondratiuk, Paweł

    2015-01-01

    Dissolution fingers (or wormholes) are formed during the dissolution of a porous rock as a result of nonlinear feedbacks between the flow, transport and chemical reactions at pore surfaces. We analyze the shapes and growth velocities of such fingers within the thin-front approximation, in which the reaction is assumed to take place instantaneously with the reactants fully consumed at the dissolution front. We concentrate on the case when the main flow is driven by the constant pressure gradient far from the finger, and the permeability contrast between the inside and the outside of the finger is finite. Using Ivantsov ansatz and conformal transformations we find the family of steadily translating fingers characterized by a parabolic shape. We derive the reactant concentration field and the pressure field inside and outside of the fingers and show that the flow within them is uniform. The advancement velocity of the finger is shown to be inversely proportional to its radius of curvature in the small P\\'{e}clet...

  12. Minimally Invasive Total Knee Arthroplasty

    Medline Plus

    Full Text Available ... the NexGen® LPS-Flex Mobile and LPS-Mobile Bearing Knees March 5, 2009 Welcome to this "OR ... MIS total knee arthroplasty with the Zimmer mobile bearing knee. We invite all of you who have ...

  13. Minimally Invasive Total Knee Arthroplasty

    Medline Plus

    Full Text Available ... NexGen® LPS-Flex Mobile and LPS-Mobile Bearing Knees March 5, 2009 Welcome to this "OR Live" ... re going to be doing an MIS total knee arthroplasty with the Zimmer mobile bearing knee. We ...

  14. Early catastrophic acetabular failure in Furlong total hip replacements

    OpenAIRE

    Knox, David; Hamilton, Steven W.; Wardlaw, Douglas; Gibson, Peter H.

    2009-01-01

    The use of uncemented hip arthroplasty prostheses with ceramic articulations are popular, especially in the young, because of a perceived reduction in wear. We highlight a complication of ceramic on polyethylene articulating couples not previously described in the Furlong replacement. Despite widespread metalosis and particulate debris, osteolysis was not initially seen. The contamination compromised subsequent revision.

  15. Early catastrophic acetabular failure in Furlong total hip replacements.

    Science.gov (United States)

    Knox, David; Hamilton, Steven W; Wardlaw, Douglas; Gibson, Peter H

    2009-03-01

    The use of uncemented hip arthroplasty prostheses with ceramic articulations are popular, especially in the young, because of a perceived reduction in wear. We highlight a complication of ceramic on polyethylene articulating couples not previously described in the Furlong replacement. Despite widespread metalosis and particulate debris, osteolysis was not initially seen. The contamination compromised subsequent revision. PMID:19384635

  16. Finger Forces in Clarinet Playing.

    Science.gov (United States)

    Hofmann, Alex; Goebl, Werner

    2016-01-01

    Clarinettists close and open multiple tone holes to alter the pitch of the tones. Their fingering technique must be fast, precise, and coordinated with the tongue articulation. In this empirical study, finger force profiles and tongue techniques of clarinet students (N = 17) and professional clarinettists (N = 6) were investigated under controlled performance conditions. First, in an expressive-performance task, eight selected excerpts from the first Weber Concerto were performed. These excerpts were chosen to fit in a 2 × 2 × 2 design (register: low-high; tempo: slow-fast, dynamics: soft-loud). There was an additional condition controlled by the experimenter, which determined the expression levels (low-high) of the performers. Second, a technical-exercise task, an isochronous 23-tone melody was designed that required different effectors to produce the sequence (finger-only, tongue-only, combined tongue-finger actions). The melody was performed in three tempo conditions (slow, medium, fast) in a synchronization-continuation paradigm. Participants played on a sensor-equipped Viennese clarinet, which tracked finger forces and reed oscillations simultaneously. From the data, average finger force (F mean ) and peak force (F max ) were calculated. The overall finger forces were low (F mean = 1.17 N, F max = 3.05 N) compared to those on other musical instruments (e.g., guitar). Participants applied the largest finger forces during the high expression level performance conditions (F mean = 1.21 N). For the technical exercise task, timing and articulation information were extracted from the reed signal. Here, the timing precision of the fingers deteriorated the timing precision of the tongue for combined tongue-finger actions, especially for faster tempi. Although individual finger force profiles were overlapping, the group of professional players applied less finger force overall (F mean = 0.54 N). Such sensor instruments provide useful insights into player

  17. Fingering Instabilities in Dewetting Nanofluids

    Science.gov (United States)

    Pauliac-Vaujour, E.; Stannard, A.; Martin, C. P.; Blunt, M. O.; Notingher, I.; Moriarty, P. J.; Vancea, I.; Thiele, U.

    2008-05-01

    The growth of fingering patterns in dewetting nanofluids (colloidal solutions of thiol-passivated gold nanoparticles) has been followed in real time using contrast-enhanced video microscopy. The fingering instability on which we focus here arises from evaporatively driven nucleation and growth in a nanoscopically thin precursor solvent film behind the macroscopic contact line. We find that well-developed isotropic fingering structures only form for a narrow range of experimental parameters. Numerical simulations, based on a modification of the Monte Carlo approach introduced by Rabani et al. [Nature (London)NATUAS0028-0836 426, 271 (2003)10.1038/nature02087], reproduce the patterns we observe experimentally.

  18. Hip Replacement

    Science.gov (United States)

    Hip replacement is surgery for people with severe hip damage. The most common cause of damage is ... therapy, pain medicines, and exercise haven't helped, hip replacement surgery might be an option for you. ...

  19. Revision of the Gunston polycentric knee arthroplasty with total knee arthroplasty.

    Science.gov (United States)

    Memişoğlu, Kaya; Müezzinoğlu, U Sefa; Kesemenli, Cumhur Cevdet

    2010-01-01

    The Gunston polycentric knee arthroplasty, first designed and performed by Frank Gunston in 1971, is the first prosthesis considering the natural knee biomechanics. Although the polycentric knee arthroplasty showed encouraging results to relieve pain and to preserve the preoperative range of motion and joint instability, the improvements in prosthesis design and arthroplasty technology rapidly made the polycentric knee prosthesis obsolete. Herein, we report a 58-year old male patient who had revision of the Gunston polycentric knee arthroplasty with total knee arthroplasty performed 32 years after the initial operation. PMID:21343693

  20. Mortality after shoulder arthroplasty

    DEFF Research Database (Denmark)

    Amundsen, Alexander; Rasmussen, Jeppe Vejlgaard; Olsen, Bo Sanderhoff;

    2016-01-01

    BACKGROUND: The primary aim was to quantify the 30-day, 90-day, and 1-year mortality rates after primary shoulder replacement. The secondary aims were to assess the association between mortality and diagnoses and to compare the mortality rate with that of the general population. METHODS: The stud...

  1. Total hip replacement in young adults with hip dysplasia

    OpenAIRE

    Engesæter, Ingvild Ø; Lehmann, Trude; Laborie, Lene B; Lie, Stein Atle; Rosendahl, Karen; Engesæter, Lars B

    2011-01-01

    Background and purpose Dysplasia of the hip increases the risk of secondary degenerative change and subsequent total hip replacement. Here we report on age at diagnosis of dysplasia, previous treatment, and quality of life for patients born after 1967 and registered with a total hip replacement due to dysplasia in the Norwegian Arthroplasty Register. We also used the medical records to validate the diagnosis reported by the orthopedic surgeon to the register. Methods Subjects born after Janua...

  2. Zinc finger proteins in cancer progression

    OpenAIRE

    Jen, Jayu; Wang, Yi-Ching

    2016-01-01

    Zinc finger proteins are the largest transcription factor family in human genome. The diverse combinations and functions of zinc finger motifs make zinc finger proteins versatile in biological processes, including development, differentiation, metabolism and autophagy. Over the last few decades, increasing evidence reveals the potential roles of zinc finger proteins in cancer progression. However, the underlying mechanisms of zinc finger proteins in cancer progression vary in different cancer...

  3. Imaging of hip joint arthroplasty

    International Nuclear Information System (INIS)

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.)

  4. Simultaneous and staged bilateral total hip arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Joergensen, Christoffer Calov; Husted, Henrik;

    2013-01-01

    Bilateral total hip arthroplasty (BTHA) and bilateral simultaneous total hip arthroplasty (BSTHA) are done increasingly. Previous studies evaluating outcomes after bilateral procedures have found different results. The aim of this study was to investigate length of hospital stay (LOS), 30 days...

  5. Interaction of finger enslaving and error compensation in multiple finger force production

    OpenAIRE

    Martin, Joel R.; Mark L. Latash; Zatsiorsky, Vladimir M.

    2008-01-01

    Previous studies have documented two patterns of finger interaction during multi-finger pressing tasks, enslaving and error compensation, which do not agree with each other. Enslaving is characterized by positive correlation between instructed (master) and non-instructed (slave) finger(s) while error compensation can be described as a pattern of negative correlation between master and slave fingers. We hypothesize that pattern of finger interaction, enslaving or compensation, depends on the i...

  6. Directed Replacement

    CERN Document Server

    Karttunen, L

    1996-01-01

    This paper introduces to the finite-state calculus a family of directed replace operators. In contrast to the simple replace expression, UPPER -> LOWER, defined in Karttunen (ACL-95), the new directed version, UPPER @-> LOWER, yields an unambiguous transducer if the lower language consists of a single string. It transduces the input string from left to right, making only the longest possible replacement at each point. A new type of replacement expression, UPPER @-> PREFIX ... SUFFIX, yields a transducer that inserts text around strings that are instances of UPPER. The symbol ... denotes the matching part of the input which itself remains unchanged. PREFIX and SUFFIX are regular expressions describing the insertions. Expressions of the type UPPER @-> PREFIX ... SUFFIX may be used to compose a deterministic parser for a ``local grammar'' in the sense of Gross (1989). Other useful applications of directed replacement include tokenization and filtering of text streams.

  7. Increased Long-Term Cardiovascular Risk After Total Hip Arthroplasty: A Nationwide Cohort Study.

    Science.gov (United States)

    Gordon, Max; Rysinska, Agata; Garland, Anne; Rolfson, Ola; Aspberg, Sara; Eisler, Thomas; Garellick, Göran; Stark, André; Hailer, Nils P; Sköldenberg, Olof

    2016-02-01

    Total hip arthroplasty is a common and important treatment for osteoarthritis patients. Long-term cardiovascular effects elicited by osteoarthritis or the implant itself remain unknown. The purpose of the present study was to determine if there is an increased risk of late cardiovascular mortality and morbidity after total hip arthroplasty surgery.A nationwide matched cohort study with data on 91,527 osteoarthritis patients operated on, obtained from the Swedish Hip Arthroplasty Register. A control cohort (n = 270,688) from the general Swedish population was matched 1:3 to each case by sex, age, and residence. Mean follow-up time was 10 years (range, 7-21).The exposure was presence of a hip replacement for more than 5 years. The primary outcome was cardiovascular mortality after 5 years. Secondary outcomes were total mortality and re-admissions due to cardiovascular events.During the first 5 to 9 years, the arthroplasty cohort had a lower cardiovascular mortality risk compared with the control cohort. However, the risk in the arthroplasty cohort increased over time and was higher than in controls after 8.8 years (95% confidence interval [CI] 7.0-10.5). Between 9 and 13 years postoperatively, the hazard ratio was 1.11 (95% CI 1.05-1.17). Arthroplasty patients were also more frequently admitted to hospital for cardiovascular reasons compared with controls, with a rate ratio of 1.08 (95% CI 1.06-1.11).Patients with surgically treated osteoarthritis of the hip have an increased risk of cardiovascular morbidity and mortality many years after the operation when compared with controls. PMID:26871792

  8. Mesofluidic controlled robotic or prosthetic finger

    Science.gov (United States)

    Lind, Randall F; Jansen, John F; Love, Lonnie J

    2013-11-19

    A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.

  9. The SABS finger ring service

    International Nuclear Information System (INIS)

    All radiation workers are required by law to wear personal dosimeters to measure the radiation dose they receive in the course of their work. However, there was a need to measure the radiation dose received by the fingers and hands, because they are much closer to the source of radiation than the rest of the body. In April 1982 a finger ring service was instituted on a routine basis. A thermoluminescent dosimeter (TLD) is used, which is suitable for both X-rays and gamma rays. Materials that are used for thermoluminescent dosimeters includes LiF:Mg, CaF2:Dy and CaSO4:Dy

  10. Femoral and obturator nerves palsy caused by pelvic cement extrusion after hip arthroplasty

    OpenAIRE

    Pawel Zwolak; Peer Eysel; Joern William-Patrick Michael

    2011-01-01

    Cement extrusion into the pelvis with subsequent palsy of the obturator and femoral nerves is a rare entity after hip replacement surgery. Cemented fixation of the acetabular cup has been considered as a safe and reliable standard procedure with very good long term results. We present a case of fifty year old female patient after hip arthroplasty procedure which suffered an obturator and femoral nerve palsy caused by extrusion of bone cement into the pelvis. Postoperative X-rays and CT-scan ...

  11. The Arthroscopic Ulnohumeral Arthroplasty: From Mini-Open to Arthroscopic Surgery

    OpenAIRE

    Ilse Degreef; Luc De Smet

    2011-01-01

    In cubarthritis—osteoarthritis of the elbow—surgical procedures may be considered to debride the elbow joint to reduce pain, to increase mobility, and to postpone joint replacement surgery. The ulnohumeral arthroplasty as described by Outerbridge and Kashiwagi was originally introduced to debride both anterior and posterior elbow compartments through a direct posterior mini-open approach. To achieve this, a distal humeral fenestration throughout the humeral fossa is performed. Although with a...

  12. Theoretical and practical aspects in total uncemented hip arthroplasty by using short femoral stem prosthesis

    OpenAIRE

    Moga, M; Pogarasteanu, ME; Barbilian, A

    2015-01-01

    Hip arthrosis, primary or secondary, is an osteoarthritic degenerative process that affects the hip joint. Primary hip arthrosis has an unknown etiology, and secondary hip arthrosis has well defined causes; of these causes, some are known to lead to arthrosis of the hip in the young age patient. The surgical treatment aims either to preserve the patient’s hip joint, or to replace the joint. The most commonly used procedure at this time is the total hip arthroplasty. The femoral component may ...

  13. Nucleus disc arthroplasty with the NUBAC™ device: 2-year clinical experience

    OpenAIRE

    Balsano, M.; Zachos, A.; Ruggiu, A.; Barca, F.; Tranquilli-Leali, P.; Doria, C.

    2011-01-01

    Low back pain (LBP) due to degenerative disc disease (DDD) is a common condition that can be treated along a continuum of care: from conservative therapies to several surgical choices. Nucleus arthroplasty is an emerging technology that could potentially fill part of the gap in the spine continuum of care. The introduction of recent technologies that allow the replacement of the degenerated disc nucleus using prosthetic devices may be considered an additional therapeutic tool that can be used...

  14. Revision of the Gunston polycentric knee arthroplasty with total knee arthroplasty

    OpenAIRE

    Memisoglu, Kaya; Muezzinoglu, U. Sefa; Kesemenli, Cumhur Cevdet

    2011-01-01

    The Gunston polycentric knee arthroplasty, first designed and performed by Frank Gunston in 1971, is the first prosthesis considering the natural knee biomechanics. Although the polycentric knee arthroplasty showed encouraging results to relieve pain and to preserve the preoperative range of motion and joint instability, the improvements in prosthesis design and arthroplasty technology rapidly made the polycentric knee prosthesis obsolete. Herein, we report a 58-year-old male patient who had ...

  15. 'Frozen finger' in anal fissures.

    Science.gov (United States)

    Chintamani; Tandon, Megha; Khandelwal, Rohan

    2009-10-01

    Acute anal fissures are usually managed by various invasive and non-invasive modalities ranging from simple lifestyle changes to chemical and surgical sphincterotomies. Frozen finger, prepared using a water-filled ordinary rubber glove, was successfully used in one hundred patients, thus providing a cost-effective and simple solution to the problem. PMID:19671780

  16. A PROSPECTIVE STUDY OF PHARMACOLOGICAL PROPHYLAXIS OF DEEP VEIN THROMBOSIS IN ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    Gopalakrishna

    2014-04-01

    Full Text Available BACKGROUND: Joint replacement surgeries were associated with significant risk of deep vein thrombosis further leading to complications like pulmonary embolism, a need for prevention of complications by using DVT prophylaxis among Indian patients. OBJECTIVE: The risk of DVT & pulmonary embolism following joint replacement surgeries were largely studied in western countries whereas the same following arthroplasty was studied to a lesser extent in India. To find out the efficacy of Pharmacological Prophylaxis against DVT (Deep Venous Thrombosis or PE (Pulmonary Embolism.To find out incidence of DVT (Deep Venous Thrombosis or PE (Pulmonary Embolism Despite prophylaxis. METHODS: prospective study of pharmacological prophylaxis of deep venous thrombosis in arthroplasty using low molecular weight heparin and aspirin .patients were investigated pre & post operatively with Doppler study for evidence of venous thrombosis. RESULTS: Distal DVT was found in two patients who underwent THR; there was no case of proximal DVT with THR and TKR. No DVT was detected in any patient who had undergone TKR preoperatively or postoperatively. CONCLUSION: We believe that though there is enough evidence in the Western literature to advocate routine thromboprophylaxis for patients undergoing total joint replacement and surgery for fractures of lower limb, there is not yet enough evidence to justify the same for Indian patients undergoing major lower limb surgery. A duplex sonography should be preferably carried out on all the elderly and high-risk patients undergoing total joint arthroplasty, Trials involving a larger number of patients in future are required.

  17. Total knee arthroplasty in vascular malformation

    Directory of Open Access Journals (Sweden)

    Harish Bhende

    2015-01-01

    Full Text Available In Klippel–Trenaunay syndrome, vascular malformations are not only in skin and superficial soft tissues but also in deep tissues like muscles bones and joints. It is well documemted that these recurrent intraarticular bleeds can cause early arthritis and joint pain. Performing arthroplasty in such patients is difficult and fraught with complications. We describe such a case where navigated total knee arthroplasty was performed with success to avoid the problems of intra medullary alignment used in the presence of intra medullary vascular malformations. We also suggest certain measures when knee arthroplasty is considered in such patients.

  18. Arthroplasty of the elbow in rheumatoid arthritis.

    Science.gov (United States)

    Kimura, C; Vainio, K

    1976-05-21

    The study consists of 208 elbow arthroplasties performed on rheumatoid arthritic patients. A straight resection of the joint was used in 53 cases and a modified Hass arthroplasty with skin interposition in 155 cases. The average postoperative range of motion in these groups was 100 degrees and 96 degrees respectively. Postoperatively the joint was painless in 81 and 67% of the elbows respectively. The Hass arthroplasty gave a better stability and extension power. The most common complications were paresthesias in the region of the ulnar nerve and bone resorption in the region of the ulnar nerve and bone resorption in the region of the olecranon fossa. PMID:779734

  19. Total Ankle Arthroplasty: An Imaging Overview

    Science.gov (United States)

    Kim, Da-Rae; Potter, Hollis G.; Li, Angela E.; Chun, Ka-Young; Jung, Yoon Young; Kim, Jin-Su; Young, Ki-Won

    2016-01-01

    With advances in implant technology, total ankle arthroplasty (TAA) has become an increasingly popular alternative to arthrodesis for the management of end-stage ankle arthritis. However, reports in the literature do not focus on the imaging features of TAA. Through a literature review, we demonstrate basic design features of the current ankle arthroplasty system, and the normal and abnormal postoperative imaging features associated with such devices. Pre- and postoperative evaluations of ankle arthroplasty mainly include radiography; in addition, computed tomography and magnetic resonance imaging provide further characterization of imaging abnormalities. Familiarization with multimodal imaging features of frequent procedural complications at various postoperative intervals is important in radiological practice. PMID:27134529

  20. 27 CFR 9.34 - Finger Lakes.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Finger Lakes. 9.34 Section... Lakes. (a) Name. The name of the viticultural area described in this section is “Finger Lakes.” (b) Approved maps. The appropriate maps for determining the boundaries of the Finger Lakes viticultural...

  1. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    Science.gov (United States)

    Ghanem, Mohamed; Glase, Almuth; Zajonz, Dirk; Roth, Andreas; Heyde, Christoph-E.; Josten, Christoph; von Salis-Soglio, Georg

    2016-01-01

    Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR) in multi-morbid patients. Patients and methods: During the period from January 1st 2007 to December 31st 2011 19 revision hip surgeries were performed in 19 patients, in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%). All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months). Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%. Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%). The most common complication encountered was the proximal migration of the bipolar head. The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%). Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as

  2. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2016-04-01

    Full Text Available Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR in multi-morbid patients.Patients and methods: During the period from January 1 2007 to December 31 2011 19 revision hip surgeries were performed in , in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%. All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months. Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%.Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%. The most common complication encountered was the proximal migration of the bipolar head.The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%. Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as well

  3. Direct anterior total hip arthroplasty: Literature review of variations in surgical technique.

    Science.gov (United States)

    Connolly, Keith P; Kamath, Atul F

    2016-01-18

    The direct anterior approach to the hip has been suggested to have several advantages compared to previously popular approaches through its use of an intra-muscular and intra-nervous interval between the tensor fasciae latae and sartorius muscles. Recent increased interest in tissue-sparing and minimally-invasive arthroplasty has given rise to a sharp increase in the utilization of direct anterior total hip arthroplasty. A number of variations of the procedure have been described and several authors have published their experiences and feedback to successfully accomplishing this procedure. Additionally, improved understanding of relevant soft tissue constraints and anatomic variants has provided improved margin of safety for patients. The procedure may be performed using specially-designed instruments and a fracture table, however many authors have also described equally efficacious performance using a regular table and standard arthroplasty tools. The capacity to utilize fluoroscopy intra-operatively for component positioning is a valuable asset to the approach and can be of particular benefit for surgeons gaining familiarity. Proper management of patient and limb positioning are vital to reducing risk of intra-operative complications. An understanding of its limitations and challenges are also critical to safe employment. This review summarizes the key features of the direct anterior approach for total hip arthroplasty as an aid to improving the understanding of this important and effective method for modern hip replacement surgeons. PMID:26807354

  4. Ulnar sided wrist pain and distal radioulnar joint osteoarthritis; is surgical arthroplasty enough?

    Directory of Open Access Journals (Sweden)

    Ronit Wollstein

    2012-05-01

    Full Text Available Distal radioulnar joint (DRUJ arthritis is a common cause of ulnar wrist pain in rheumatoid and osteoarthritis. Modified arthroplasty for the DRUJ is a minimally invasive procedure for the treatment of isolated DRUJ osteoarthritis. The purpose of this study was to evaluate the efficacy of the procedure and the incidence of related ulnar wrist pathology as well as the incidence of subsequent ulnar wrist surgeries. All patients having modified arthroplasty for the DRUJ between 1994-2008 were retrospectively reviewed. Measurements included range of motion, grip strength, and subjective status. Data regarding other wrist surgeries was recorded. There were 29 patients, 23 of which had a follow-up of over 8 weeks (average 16 months (SD=24. Fourteen patients had no to minimal pain, 6 had pain with heavier activities (2 severe, and 2 reported constant pain at the surgical site. Of the 4 more painful patients, three had additional surgery after the DRUJ arthroplasty. In all 96% of the patients had another procedure involving the ulnar- wrist complex either prior to surgery, at the time of surgery or following surgery for modified arthroplasty. We suggest that pathology involving the ulnar-wrist complex is often a syndrome consisting of multiple related diagnoses including but not limited to arthritis of the DRUJ. Multiple procedures may be needed, or a more aggressive approach such as ulnar head replacement may be indicated so that pathology at both the distal radioulnar and ulnocarpal joints is addressed concomitantly.

  5. Multi-finger interaction during involuntary and voluntary single finger force changes

    OpenAIRE

    J R Martin; Zatsiorsky, V.M.; Latash, M.L.

    2010-01-01

    Two types of finger interaction are characterized by positive co-variation (enslaving) or negative co-variation (error compensation) of finger forces. Enslaving reflects mechanical and neural connections among fingers, while error compensation results from synergic control of fingers to stabilize their net output. Involuntary and voluntary force changes by a finger were used to explore these patterns. We hypothesized that synergic mechanisms will dominate during involuntary force changes, whi...

  6. BIOLOGIC JOINT RECONSTRUCTION: ALTERNATIVES TO ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    Brian J. Cole

    2009-06-01

    Full Text Available A comprehensive source of information in the management of cartilage lesions of major joints using nonoperative or surgical techniques other than total joint replacement. The text also includes chapters in basic sciences, imaging and rehabilitation.The editors are aiming to provide a reference about the latest concepts and techniques in the treatment of cartilage lesions including future aspects by a comprehensive approach to the alternative joint restoration procedures such as biological, pharmacological and surgical techniques of cartilage repairing and partial resurfacing etc.Orthopedic surgeons in sports medicine, orthopedic surgeons performing joint replacements, orthopedic resident and fellows will be the main audiences.The text is 349 pages, divided into 34 chapters in 7 sections. Section I is "Background-articular cartilage and allograft processing" including chapters about pathology, patient evaluation, imaging and allograft processing. Section II is "Nonoperative treatment" including chapters about neutraceuticals, pharmacological treatment and rehabilitation. Section III is "Operative treatment-knee" including chapters about arthroscopic debridment, microfracture, osteochondral autograft transplantation, mosaicplasty, osteochondral autograft transfer, osteochondral allografts, autologous chondrocyte implantation, existing cell-based technologies, minimally invasive second-generation autologous chondrocyte implantation, future development in cartilage repair, meniscus transplantation, management of OCD, patellafemoral chondral disease, proximal tibial and distal femoral osteotomies, unicompartmental arthritis current techniques, unicompartmental knee replacement. Section IV is "Operative treatment-Hip" including chapters about hip arthroscopy and arthroscopic partial resurfacing, related osteotomies. Section V is "operative treatment-shoulder" including chapters about arthroscopic debridment and release, biologic resurfacing and

  7. Heterotopic Ossification Causing Radiculopathy after Lumbar Total Disc Arthroplasty.

    Science.gov (United States)

    Jackson, Keith L; Hire, Justin M; Jacobs, Jeremy M; Key, Charles C; DeVine, John G

    2015-06-01

    To date, no reports have presented radiculopathy secondary to heterotopic ossification following lumbar total disc arthroplasty. The authors present a previously unpublished complication of lumbar total disk arthroplasty (TDA) secondary to heterotopic ossification (HO) in the spinal canal, and they propose a modification to the McAfee classification of HO. The patient had undergone an L5/S1 lumbar TDA two years prior due to discogenic back pain. His preoperative back pain was significantly relieved, but he developed new, atraumatic onset radiculopathy. Radiographs and a computed tomography myelogram revealed an implant malposition posteriorly with heterotopic bone formation in the canal, causing an impingement of the traversing nerve root. Revision surgery was performed with implant extraction, L5/S1 anterior lumbar interbody fusion, supplemental posterior decompression, and pedicle screw fixation. The patient tolerated the procedure well, with complete resolution of the radicular leg pain. At a two-year follow up, the patient had a solid fusion without subsidence or recurrence of heterotopic bone. This case represents a novel pattern of heterotopic ossification, and it describes a previously unreported cause for implant failure in lumbar disc replacement surgery-reinforcing the importance of proper intraoperative component positioning. We propose a modification to the existing McAfee classification of HO after TDA with the addition of Class V and VI HO. PMID:26097664

  8. Gravity-driven fingering in unsaturated fractures

    International Nuclear Information System (INIS)

    Gravity-driven wetting-front instability is known to occur in both porous media and Hele-Shaw cells. A systematic investigative procedure for studying gravity-driven fingering in unsaturated, rough-walled fractures is described. As a first step toward understanding this system, experiments were performed in an analogue fracture consisting of two roughened glass plates held in close contact. Results from preliminary experiments in both initially dry and wet analogue fractures are presented, including measurements taken from individual fingers within a fully unstable flow field. For initially dry fractures, increasing the volume of fluid contained in the front leads to increases in both finger width and velocity. Finger velocity also was observed to increase with gravitational gradient. Once a finger structure develops in an initially dry fracture, the structure persists in subsequent infiltration events. In uniformly wet fractures, fingers are found to be more numerous and thinner and to have higher velocity than fingers formed in initially dry fractures

  9. Does finger sense predict addition performance?

    Science.gov (United States)

    Newman, Sharlene D

    2016-05-01

    The impact of fingers on numerical and mathematical cognition has received a great deal of attention recently. However, the precise role that fingers play in numerical cognition is unknown. The current study explores the relationship between finger sense, arithmetic and general cognitive ability. Seventy-six children between the ages of 5 and 12 participated in the study. The results of stepwise multiple regression analyses demonstrated that while general cognitive ability including language processing was a predictor of addition performance, finger sense was not. The impact of age on the relationship between finger sense, and addition was further examined. The participants were separated into two groups based on age. The results showed that finger gnosia score impacted addition performance in the older group but not the younger group. These results appear to support the hypothesis that fingers provide a scaffold for calculation and that if that scaffold is not properly built, it has continued differential consequences to mathematical cognition. PMID:26993292

  10. Patients’ decision making in total knee arthroplasty

    OpenAIRE

    Barlow, T.; Griffin, D.; Barlow, D; Realpe, A.

    2015-01-01

    Objectives A patient-centred approach, usually achieved through shared decision making, has the potential to help improve decision making around knee arthroplasty surgery. However, such an approach requires an understanding of the factors involved in patient decision making. This review’s objective is to systematically examine the qualitative literature surrounding patients’ decision making in knee arthroplasty. Methods A systematic literature review using Medline and Embase was conducted to ...

  11. Management of complications after total shoulder arthroplasty

    OpenAIRE

    Josef K Eichinger; Galvin, Joseph W.

    2015-01-01

    The outcomes of total shoulder arthroplasty (TSA) for painful arthritis of the glenohumeral joint are excellent with significant improvement in pain and function. Increased use of total shoulder arthroplasty over the past decade has led to identification of common complications. Although the complication rate is low, accurate and timely diagnosis, appropriate management, and implementation of methods for prevention are critical to a successful long-term outcome. The most common complications ...

  12. Polyethylene in knee arthroplasty: A review

    OpenAIRE

    Chakrabarty, Gautam; Vashishtha, Mayank; Leeder, Daniel

    2015-01-01

    Polyethylene (PE) has been used extensively in knee arthroplasty since the mid 20th century. Progress in material manufacturing and processing has led to newer polyethylenes over last few decades with different material properties. It has been established that PE wear in knee arthroplasty causes particle induced osteolysis which is the main reason for late failure and requires revision surgery. Although there are various causes of wear, the properties of PE have long been a matter of investig...

  13. Finger Indexed Sets: New Approaches

    CERN Document Server

    Sioutas, Spyros

    2008-01-01

    In the particular case we have insertions/deletions at the tail of a given set S of $n$ one-dimensional elements, we present a simpler and more concrete algorithm than that presented in [Anderson, 2007] achieving the same (but also amortized) upper bound of $O(\\sqrt{logd/loglogd})$ for finger searching queries, where $d$ is the number of sorted keys between the finger element and the target element we are looking for. Furthermore, in general case we have insertions/deletions anywhere we present a new randomized algorithm achieving the same expected time bounds. Even the new solutions achieve the optimal bounds in amortized or expected case, the advantage of simplicity is of great importance due to practical merits we gain.

  14. FINGER-VEIN RECOGNITION SYSTEMS

    Directory of Open Access Journals (Sweden)

    A.Haritha Deepthi

    2015-10-01

    Full Text Available As the Person‟s/Organization‟s Private information‟s are becoming very easy to access, the demand for a Simple, Convenient, Efficient, and a highly Securable Authentication System has been increased. In considering these requirements for data Protection, Biometrics, which uses human physiological or behavioral system for personal Identification has been found as a solution for these difficulties. However most of the biometric systems have high complexity in both time and space. So we are going to use a Real time Finger-Vein recognition System for authentication purposes. In this paper we had implemented the Finger Vein Recognition concept using MATLAB R2013a. The features used are Lacunarity Distance, Blanket Dimension distance. This has more accuracy when compared to conventional methods.

  15. Finger clubbing in cystic fibrosis.

    OpenAIRE

    Pitts-Tucker, T J; Miller, M G; Littlewood, J M

    1986-01-01

    Finger clubbing was measured in 73 of 105 patients with cystic fibrosis undergoing full assessment. The sign correlated well with the chest x ray score and indices of pulmonary function and infection but not with weight, height, age, liver function, or degree of fat malabsorption. The presence of clubbing suggests appreciable pulmonary involvement. Most probably its progression indicates a deterioration in pulmonary state. In both instances increased efforts should be made to treat the infect...

  16. Finger tremor in Parkinson's disease.

    OpenAIRE

    Lakie, M; Mutch, W J

    1989-01-01

    Finger tremor was investigated in 20 patients (age range 54-88 yr) diagnosed as suffering from idiopathic Parkinson's disease and six controls of a similar age and no known neurological abnormality. In nine of the patients tremor was not clinically obvious. When the tremor of these patients was recorded immediately after voluntary movement and subjected to instrumental analysis there were consistently observable differences from the controls. Such analysis may have diagnostic potential when t...

  17. Revision total elbow arthroplasty with the linked Coonrad-Morrey total elbow arthroplasty

    DEFF Research Database (Denmark)

    Plaschke, Hans Christian; Thillemann, Theis; Belling-Sørensen, Anne Kathrine; Olsen, Bo

    2013-01-01

    In this retrospective study we evaluated the short- to medium-term results after 20 Coonrad-Morrey revision total elbow arthroplasties (TEAs).......In this retrospective study we evaluated the short- to medium-term results after 20 Coonrad-Morrey revision total elbow arthroplasties (TEAs)....

  18. Joint Line Reconstruction in Navigated Total Knee Arthroplasty Revision

    Science.gov (United States)

    2012-05-16

    Revision Total Knee Arthroplasty Because of; Loosening; Instability; Impingement; or Other Reasons Accepted as Indications for TKA Exchange.; The Focus is to Determine the Precision of Joint Line Restoration in Navigated vs. Conventional Revision Total Knee Arthroplasty

  19. Ulnar Nerve Compression after Silastic Ulnar Head Replacement

    OpenAIRE

    El-Gammal, Tarek A.; Blair, William F.

    1991-01-01

    A patient with silastic radiocarpal and ulnar head replacement arthroplasty presented six years after the operation with symptoms of ulnar neuropathy. Bone resorption of the distal ulna resulted in volar subluxation of the ulnar head implant which compressed the ulnar nerve at its entrance into Guyon's canal. Removal of the implant and decompression of the nerve resulted in recovery of ulnar nerve funcions. Compression neuropathy of the ulnar nerve should be considered a potential complicatio...

  20. Declining needs for total joint replacements for rheumatoid arthritis

    OpenAIRE

    Khan, Nasim A; Sokka, Tuulikki

    2011-01-01

    This millennium brings new views to rheumatology. Total joint replacement surgery is needed less often as active treatment strategies combined with availability of new medications has led to more effective rheumatoid arthritis control. This was beautifully shown in a recent issue of Arthritis Research & Therapy by a Swedish study that uses data from national registers and compares incidence rates for total hip and knee arthroplasties before and after the establishment of biologic agents use f...

  1. Ninety day mortality and its predictors after primary shoulder arthroplasty: an analysis of 4,019 patients from 1976-2008

    Directory of Open Access Journals (Sweden)

    Singh Jasvinder A

    2011-10-01

    Full Text Available Abstract Background Examine 90-day postoperative mortality and its predictors following shoulder arthroplasty Methods We identified vital status of all adults who underwent primary shoulder arthroplasty (Total shoulder arthroplasty (TSA or humeral head replacement (HHR at the Mayo Clinic from 1976-2008, using the prospectively collected information from Total Joint Registry. We used univariate logistic regression models to assess the association of gender, age, body mass index, American Society of Anesthesiologist (ASA class, Deyo-Charlson comorbidity index, an underlying diagnosis and implant fixation with odds of 90-day mortality after TSA or HHR. Multivariable models additionally adjusted for the type of surgery (TSA versus HHR. Adjusted Odds ratio (OR with 95% confidence interval (CI were calculated. Results Twenty-eight of the 3, 480 patient operated died within 90-days of shoulder arthroplasty (0.8%. In multivariable-adjusted analyses, the following factors were associated with significantly higher odds of 90-day mortality: higher Deyo-Charlson index (OR, 1.54; 95% CI:1.39, 1.70; p Conclusions 90-day mortality following shoulder arthroplasty was low. An underlying diagnosis of tumor, higher comorbidity and higher ASA class were risk factors for higher 90-day mortality, while higher BMI was protective. Pre-operative comorbidity management may impact 90-day mortality following shoulder arthroplasty. A higher unadjusted mortality in patients undergoing TSA versus HHR may indicate the underlying differences in patients undergoing these procedures.

  2. Transfusion practice in hip arthroplasty - a nationwide study

    DEFF Research Database (Denmark)

    Jans, Øivind; Kehlet, H; Hussain, Zubair Butt;

    2011-01-01

    Background and Objectives The optimal transfusion strategy in hip arthroplasty remains controversial despite existing guidelines. The aim of this study was to evaluate the transfusion practice in patients undergoing primary total hip arthroplasty (THA) or revision total hip arthroplasty (RTHA) in...

  3. Anteroposterior glide versus rotating platform low contact stress (LCS knee arthroplasty: a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Wynn-Jones Charles

    2007-08-01

    Full Text Available Abstract Background Fifty thousand knee replacements are performed annually in the UK at an estimated cost of £150 million. Post-operative improvement depends on a number of factors including implant design and patient associated factors. To our knowledge there are no published study's comparing the results of AP glide and rotating platform designs of LCS knee arthroplasty. Therefore we feel that a study is required to investigate and compare the effects of two types of LCS total knee arthroplasty on joint proprioception and range of motion. Methods/Design Patients will be randomised to receive either a LCS AP glide or Rotating platform prosthesis. Clinical scores (Oxford knee score, American knee society score, EuroQol, range of motion and proprioception will be assessed prior to and at 3,6, 12 and 24 months after the operation. Proprioception will be assessed in terms of absolute error angle (mean difference between the target angle and the response angle. Knee angles will be measured in degrees using an electromagnetic tracking device, Polhemus 3Space Fastrak that detects positions of sensors placed on the test limb. Student's t-test will be used to compare the mean of two groups. Discussion Evidence is lacking concerning the best prosthesis to use for patients undergoing total knee replacement. This pragmatic randomised trial will test the null hypothesis that anteroposterior glide LCS knee arthroplasty does not result in better post operative knee motion and proprioception as compared to rotating platform LCS knee. Trial Registration ISRCTN52943804

  4. Outcome after total elbow arthroplasty

    DEFF Research Database (Denmark)

    Plaschke, Hans Christian; Thillemann, Theis M; Brorson, Stig;

    2015-01-01

    BACKGROUND: Total elbow arthroplasties (TEAs) are traditionally grouped into linked and unlinked design. The aim was to analyze the difference in clinical outcomes after TEA based on implant design and indication for surgery and to evaluate primary and revision TEAs. METHODS: A total of 167 TEAs...... (126 primary and 41 revision TEAs) in 141 patients were evaluated with patient-reported outcome measure by the Oxford Elbow Score (OES) and clinically assessed with the Mayo Elbow Performance Score (MEPS), range of motion (ROM), and standard radiographs. RESULTS: The mean follow-up was 10.5 years for...... primary and 7.5 years for revision TEAs. There was no difference in OES or MEPS between linked and unlinked primary TEAs. The OES score in the social-psychological domain was significantly lower in TEAs performed due to fracture (67) compared with rheumatoid arthritis (81; P = .025). ROM in extension...

  5. [Diagnosis in patients with a painful arthroplasty].

    Science.gov (United States)

    Carrega, Giuliana; Antonini, Andrea; Burastero, Giorgio; Casalino-Finocchio, Giorgetta; Ronca, Agostina; Salomone, Carlo; Riccio, Giovanni

    2015-06-01

    The differential diagnosis between asepting loosening or prosthetic joint infection is not always easy. Tc-99m-labelled leucocyte scans, frozen section and histology can help recognise doubtful cases. We report the experience of the Unit for Infectious Diseases and Septic Orthopaedics of the ASL-2 Liguria, Italy, with a Tc-99m-labelled leucocyte scan and intraoperative frozen section to choose the best therapeutic approach: one-stage or two-stage exchange or arthrodesis-arthroplastica. All cases underwent histology and intraoperative cultures to confirm the diagnosis, and the effectiveness of the approach was evaluated at follow up after 18 months. From January 2011 to December 2012, 36 patients were evaluated (21 hip and 15 knee arthroprosthesis). The Tc-99m-labelled leukocyte scan was positive in 31 and negative in 5 patients. Frozen section was negative in 7 patients. Five of them were patients with a negative Tc-99m-labelled leucocyte scan and were treated successfully with one-stage exchange, even if, in one of them, Enterococcus faecalis was isolated at replacement and suppressive antibiotic treatment was needed. The other 31 patients were treated with arthrodesis arthroplasty (3 patients) or a two-stage exchange. In this group the Tc-99m-labelled leucocyte scan was positive in all patients and the frozen section was positive in 29/31 cases with 6% false negative. Histology was positive in 27/31 with 13% of false negative. The sensitivity and specificity value was respectively 90% and 100% in the frozen section, 84% and 100% in histology. Cultures were positive in 23/31 cases. Patients subjected to two-stage exchange were evaluated again during prosthesis replacement but the results of the Tc-99m-labelled leucocyte scan and histology showed unclear results more frequently: the Tc-99m-labelled leucocyte scan was positive in two cases, the frozen section in three and histology in seven in spite of positive culture in three cases and one relapse in a patient

  6. Bilateral hip arthroplasty: is 1-week staging the optimum strategy?

    Directory of Open Access Journals (Sweden)

    Willis-Owen Charles A

    2010-11-01

    Full Text Available Abstract Seventy-nine patients underwent bilateral hip arthroplasty staged either at 1 week (Group 1 or after greater intervals (as suggested by the patients, mean 44 weeks, range 16-88 weeks (Group 2, over a five year period at one Institution. Sixty-eight patients (29 bilateral hip resurfacings and 39 total hip replacements completed questionnaires regarding their post-operative recovery, complications and overall satisfaction with the staging of their surgery. There was no significant age or ASA grade difference between the patient groups. Complication rates in the two groups were similar and overall satisfaction rates were 84% in Group 1 (n = 32 and 89% in Group 2 (n = 36. Cumulative hospital lengths of stay were significantly longer in Group 1 patients (11.9 days vs 9.1 days(p The mean time to return to part-time work was 16.4 weeks for Group 1, and a cumulative 17.2 weeks (8.8 and 8.4 weeks for Group 2. The time to return to full-time work was significantly shorter for Group 1 patients (21.0 weeks, compared with a cumulative 29.7 weeks for Group 2(p Hip resurfacing patients in Group 2 had significantly shorter durations of postoperative pain and were able to return to part-time and full time work sooner than total hip arthroplasty patients. There was a general trend towards a faster recovery and resumption of normal activities following the second operation in Group 2 patients, compared with the first operation. Bilateral hip arthroplasty staged at a 1-week interval resulted in an earlier resolution of hip pain, and an earlier return to full-time work (particularly following total hip replacement surgery, with high levels of patient satisfaction and no increased risk in complications; however the hospital length of stay was significantly longer. The decision for the timing of staged bilateral surgery should be made in conjunction with the patient, making adjustments to accommodate their occupational needs and functional demands.

  7. 21 CFR 888.3200 - Finger joint metal/metal constrained uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3200 Section 888.3200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/metal constrained uncemented prosthesis. (a) Identification. A finger joint metal/metal constrained uncemented prosthesis is a device intended to be implanted to replace a metacarpophalangeal...

  8. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3220 Section 888.3220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace a metacarpophalangeal...

  9. On the fly finger knuckle print authentication

    Science.gov (United States)

    Abe, Narishige; Shinzaki, Takashi

    2014-05-01

    Finger knuckle print authentication has been researched not only as a supplemental authentication modality to fingerprint recognition but also as a method for logging into a PC or entering a building. However, in previous works, some specific devices were necessary to capture a finger knuckle print and users had to keep their fingers perfectly still to capture their finger knuckle. In this paper, we propose a new on the fly finger knuckle print authentication system using a general web camera. In our proposed authentication system, users can input their finger knuckle prints without needing their hand to remain motionless during image capture. We also evaluate the authentication accuracy of the proposed system, achieving an 7% EER under best conditions.

  10. Application of autoradiography in finger print analysis

    International Nuclear Information System (INIS)

    In order to broaden the possibilities of developing latent finger prints a tracer technique has been developed using sup(110m)Ag and autoradiographic imaging. This method has been tested on glass, paper and certain plastics. On paper it is possible to visualize finger prints even after previous development using Ninhydrin. It is shown that usable finger prints may be obtained also from materials from which they cannot be obtained using classical methods, e.g., polyethylene and simulated leather. (author)

  11. Nodular fasciitis of the finger

    Energy Technology Data Exchange (ETDEWEB)

    Kijima, Hiroaki; Okada, Kyoji; Ito, Hiroki; Shimada, Yoichi; Itoi, Eiji [Akita University School of Medicine, Department of Orthopedic Surgery, Akita (Japan); Nanjo, Hiroshi [Akita University Hospital, Department of Clinical Pathology, Akita (Japan)

    2005-02-01

    Nodular fasciitis is a benign reactive lesion, often mistaken for a soft tissue sarcoma in clinical practice. Involvement of the finger is very rare and, as a result, in this location the lesion has sometimes been treated by ray amputation because of misdiagnosis. We report on the clinical and histological features of nodular fasciitis in a 30-year-old man who was treated by excisional biopsy. There has been no evidence of local recurrence at the recent follow-up 8 years after surgery. The importance of careful histological examination to avoid radical surgery should be emphasized because marginal excision can provide good results in the treatment of nodular fasciitis. (orig.)

  12. An unusual case of persistent groin pain after total hip arthroplasty: a case report

    Directory of Open Access Journals (Sweden)

    Friederich Niklaus F

    2011-02-01

    Full Text Available Abstract Introduction Arthroplasty is a well-established routine elective surgical procedure in orthopaedics. To a great extent, diagnosis, treatment and post-operative rehabilitation in these patients is standardised. In a busy clinic, surgeons from time to time tend to focus their attention on common causes of joint pain, but it may lead them to overlook sinister but less common pathologies. Here we report a case of a patient with groin pain due to pre-operatively undetected pelvic metastases from a pyeloureteral carcinoma who underwent total hip arthroplasty. There are several case reports which deal with primary or secondary tumours which were either discovered at the time of replacement surgery or developed at the site of prosthesis years after total hip or knee replacement. To the best of our knowledge, this is the first case report in which a metastatic cancer was missed pre-operatively and intra-operatively both by the radiologist and by the orthopaedic surgeon and should be reported so that surgeons are reminded to be careful when dealing with seemingly routine cases. Case presentation A 79-year-old Caucasian woman presented to the arthroplasty clinic with groin pain. Initial radiographs showed subtle bilateral abnormalities in the pelvis. Neither the radiologist nor the orthopaedic surgeon recognized it. A diagnosis of osteoarthritis of the hip was established, and she underwent total hip arthroplasty. Despite initial improvement, the patient came back with worsening hip pain three months later. Further radiological examination revealed multiple metastatic lesions throughout the pelvis due to a pyeloureteral carcinoma. Conclusions This case report emphasizes the importance of meticulous, unbiased pre-operative assessment of patients and their radiographs, even in so-called routine clinical cases. Often subtle radiological changes are classed as normal, especially if they are bilateral. Further radiological imaging should be recommended

  13. Ultrafast High-Resolution Mass Spectrometric Finger Pore Imaging in Latent Finger Prints

    OpenAIRE

    Christian Elsner; Bernd Abel

    2014-01-01

    Latent finger prints (LFPs) are deposits of sweat components in ridge and groove patterns, left after human fingers contact with a surface. Being important targets in biometry and forensic investigations they contain more information than topological patterns. With laser desorption mass spectrometry imaging (LD-MSI) we record ‘three-dimensional' finger prints with additional chemical information as the third dimension. Here we show the potential of fast finger pore imaging (FPI) in latent fin...

  14. Persistent non-specific FDG uptake on PET imaging following hip arthroplasty

    International Nuclear Information System (INIS)

    Hip arthroplasty is a common surgical procedure, but the diagnosis of infection associated with hip arthroplasty remains challenging. Fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) has been shown to be a promising imaging modality in settings where infection is suspected. However, inflammatory reaction to surgery can result in increased FDG uptake at various anatomic locations, which may erroneously be interpreted as sites of infection. The purpose of this study was to assess the patterns and time course of FDG accumulation following total hip replacement over an extended period of time. Firstly, in a prospective study nine patients with total hip replacement were investigated to determine the patterns of FDG uptake over time. Three FDG-PET scans were performed in each patient at about 3, 6 and 12 months post arthroplasty. Secondly, in a retrospective analysis, the medical and surgical history and FDG-PET imaging results of 710 patients who had undergone whole-body scans for the evaluation of possible malignant disorders were reviewed. The history of arthroplasty and FDG-PET findings in the hip region were reviewed for this study. Patients with symptomatic arthroplasties or related complaints during FDG-PET scanning were excluded from the analysis. During the entire study period, all nine patients enrolled in the prospective study were demonstrated to have increased FDG uptake around the femoral head or neck portion of the prosthesis that extended to the soft tissues surrounding the femur. Among the patients reviewed in the retrospective study, 18 patients with a history of 21 hip arthroplasties who were asymptomatic at the time of FDG-PET scan met the criteria for inclusion. The time interval between the hip arthroplasty and the FDG-PET study ranged from 3 months to 288 months (mean±SD: 80.4±86.2 months). In 81% (17 of 21) of these prostheses, increased FDG uptake could be noted around the femoral head or neck portion of the

  15. Fluid Mixing from Viscous Fingering

    CERN Document Server

    Jha, Birendra; Juanes, Ruben

    2010-01-01

    We study, by means of numerical simulation, the mixing of two fluids of different viscosities in advection-dominated flows in a porous medium. It is well known that when a less viscous fluid displaces a more viscous fluid, the displacement front is unstable and leads to the formation of a pattern known as viscous fingering. We present a high-resolution simulation approach that is stable for arbitrary viscosity ratios, and study mixing under different configurations with viscosity contrasts up to M = 400. We observe, in agreement with lab experiments, that for high-M displacements, the growth of new fingers follows the trace of previous ones. This channeling effect, which is a result of the nonlocal coupling through the pressure field, greatly reduces mixing. A two-equation mixing model using the scalar variance and its dissipation rate is derived from the advection-diffusion equation. It provides a measure of effective diffusivity due to convective and diffusive mixing processes. Our analysis predicts the opt...

  16. Reversed cross finger subcutaneous flap: A rapid way to cover finger defects

    Directory of Open Access Journals (Sweden)

    Fejjal Nawfal

    2008-01-01

    Full Text Available Adequate coverage of dorsal finger wounds is often a challenge. The reversed cross finger subcutaneous flap to cover defects on the dorsum of phalanx constitutes an excellent option for coverage of wounds over the middle and distal phalanges of the index, middle, ring, and small fingers. It′s an easy flap and represents our first choice to cover those defects.

  17. The instability of wrist joint and total wrist replacement.

    Science.gov (United States)

    Ma, Jin-Xing; Xu, Yong-Qing

    2016-02-01

    Total wrist arthroplasty are not used as widely as total knee and hip replacement. The functional hands are requiring surgeons to design a durable and functional satisfying prosthesis. This article will list the main reasons that cause the failure of the prosthesis. Some remarkable and representative prostheses are listed to show the devolvement of total wrist prosthesis and their individual special innovations to fix the problems. And the second part we will discuss the part that biomechanical elements act in the total wrist replacement (TWA). Summarize and find out what the real problem is and how we can find a way to fix it. PMID:27033274

  18. Fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik

    2012-01-01

    Fast-track hip and knee arthroplasty aims at giving the patients the best available treatment at all times, being a dynamic entity. Fast-track combines evidence-based, clinical features with organizational optimization including a revision of traditions resulting in a streamlined pathway from...... clinical and organizational aspects of fast-track hip and knee arthroplasty (I–IX). A detailed description of the fast-track set-up and its components is provided. Major results include identification of patient characteristics to predict length of stay and satisfaction with different aspects of the...... hospital stay (I); how to optimize analgesia by using a compression bandage in total knee arthroplasty (II); the clinical and organizational set-up facilitating or acting as barriers for early discharge (III); safety aspects following fast-track in the form of few readmissions in general (IV) and few...

  19. Intrusion Characteristics of Three Bone Cements for Tibial Component of Total Knee Arthroplasty in a Cadaveric Bone Model.

    Science.gov (United States)

    Walden, Justin K; Chong, Alexander C M; Dinh, Nam L; Adrian, Scott; Cusick, Robert; Wooley, Paul H

    2016-01-01

    The purpose of this study was to evaluate and compare the intrusion characteristics of Simplex-HV to Simplex-P and Palacos-R in cadaveric proximal tibial bone. Eighteen fresh-frozen cadaver proximal tibiae were examined with standard arthroplasty tibial cuts. Each tibia was randomly assigned to receive one of the three bone cements for use with finger packing technique. Sagittal sections were prepared and analyzed using digital photography and stereoscopic micrographs to evaluate cement intrusion characteristics. The cement penetration depth was measured from the tibial bone cut surface, which did not include the cement thickness under the tibial base plate. Significant differences were detected in the bone cement penetration between the three cements. Penetration was increased using the Simplex-HV (average, 2.7 mm; range, 2.0-3.0 mm) compared with Simplex-P (average, 2.2 mm) and Palacos-R (average, 1.8 mm). These depths approximate to 3.7, 3.2, and 2.8 mm of total cement penetration, respectively. The data suggest that high-viscosity bone cement may provide good fixation of the tibial component of a total knee arthroplasty when using the finger packing technique. PMID:27518289

  20. Surgical Treatment of Trigger Finger: Open Release

    Directory of Open Access Journals (Sweden)

    Firat Ozan

    2016-01-01

    Full Text Available In this study, open A1 pulley release results were evaluated in patients with a trigger finger diagnosis. 45 patients (29 females, 16 males, mean age 50.7 ± 11.9; range (24-79, 45 trigger fingers were released via open surgical technique. On the 25 of 45 cases were involved in the right hand and 16 of them were at the thumb, 2 at index, 6 at the middle and 1 at ring finger. Similarly, at the left hand, 15 of 20 cases were at the thumb, 1 at the index finger, 2 at middle finger and 2 at ring finger. Average follow-up time was 10.2 ± 2.7 (range, 6-15 months. Comorbidities in patients were; diabetes mellitus at 6 cases (13.3%, hypertension at 11 cases (24.4%, hyperthyroidism at 2 cases (4.4%, dyslipidemia at 2 cases (4.4% and lastly 2 cases had carpal tunnel syndrome operation. The mean time between the onset of symptoms to surgery was 6.9 ± 4.8 (range, 2-24 months. Patient satisfaction was very good in 34 cases (75.4% and good in 11 (24.6% patients. The distance between the pulpa of the operated finger and the palm was normal in every case postoperatively. We have not encountered any postoperative complications. We can recommend that; A1 pulley release via open incision is an effective and reliable method in trigger finger surgery.

  1. Axon reflexes in human cold exposed fingers

    NARCIS (Netherlands)

    Daanen, H.A.M.; Ducharme, M.B.

    2000-01-01

    Exposure of fingers to severe cold induces cold induced vasodilation (CIVD). The mechanism of CIVD is still debated. The original theory states that an axon reflex causes CIVD. To test this hypothesis, axon reflexes were evoked by electrical stimulation of the middle fingers of hands immersed in wat

  2. Revision of infected knee arthroplasties in Denmark

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Jørgensen, Christoffer C; Bagger, Jens;

    2016-01-01

    Background and purpose - The surgical treatment of periprosthetic knee infection is generally either a partial revision procedure (open debridement and exchange of the tibial insert) or a 2-stage exchange arthroplasty procedure. We describe the failure rates of these procedures on a nationwide...... basis. Patients and methods - 105 partial revisions (100 patients) and 215 potential 2-stage revision procedures (205 patients) performed due to infection from July 1, 2011 to June 30, 2013 were identified from the Danish Knee Arthroplasty Register (DKR). Failure was defined as surgically related death...

  3. LAXS investigation of finger phantoms

    International Nuclear Information System (INIS)

    Osteoporosis is a bone condition that is caused mainly by the degradation of trabecular and cortical bone resulting in the decrease of bone strength and eventually leads to bone fracture. A low angle X-ray scattering (LAXS) system that uses mainly the coherent scattering process for the characterisation of materials was constructed to study such bone conditions. Several finger phantoms were fabricated to simulate bone of varying densities. The LAXS method was able to identify the changes in bone density quite well by comparing energy dispersive X-ray diffraction patterns as well as the angular patterns. Quantitative information can be extracted from such patterns that relate to bone loss. Signature patterns at low exposure times were produced in order to reduce the dose received with reasonable identification power but at slightly higher statistical errors compared with long exposure patterns. Use of other parameters to increase the sensitivity was attempted

  4. A Case Report: An Acute Thrombus in the Femoral Artery following Total Hip Arthroplasty

    Science.gov (United States)

    GBS, Varun; N, Muralidhar; Bharathidasan, Kavya

    2016-01-01

    Introduction: Vascular complications post-operative to a total hip arthroplasty are a very rare phenomenon. Only a few isolated cases have been reported to date. Diagnosis of such a case in a timely manner so as to preserve the limb is also difficult due to the subtle signs with which the patient presents. We report a case of complete occlusion of the common femoral artery following total hip arthroplasty due to acute thrombus formation. Case Presentation: A 56 year old Indian male patient underwent a cemented total hip replacement. Three hours post-operatively, the patient’s left lower limb was found to be pale and pulseless. Angiography showed complete occlusion of the left common femoral artery. Thrombectomy was carried out immediately and the patient recovered well. Conclusion: Vascular injuries are highly unusual findings following a total hip arthroplasty. Careful pre-operative and immediate post-operative monitoring of the patient is essential. Signs such as limb ischemia, absence of pulses, etc. must be recognized as early as possible and the necessary investigations and procedures should be carried out without any delay. PMID:27299128

  5. Lower limb joint replacement in rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Clement Nicholas D

    2012-06-01

    Full Text Available Abstract Introduction There is limited literature regarding the peri-operative and surgical management of patients with rheumatoid disease undergoing lower limb arthroplasty. This review article summarises factors involved in the peri-operative management of major lower limb arthroplasty surgery for patients with rheumatoid arthritis. Methods We performed a search of the medical literature, using the PubMed search engine (http://www.pubmed.gov. We used the following terms: ‘rheumatoid’ ‘replacement’ ‘arthroplasty’ and ‘outcome’. Findings The patient should be optimised pre-operatively using a multidisciplinary approach. The continued use of methotrexate does not increase infection risk, and aids recovery. Biologic agents should be stopped pre-operatively due the increased infection rate. Patients should be made aware of the increased risk of infection and periprosthetic fracture rates associated with their disease. The surgical sequence is commonly hip, knee and then ankle. Cemented total hip replacement (THR and total knee replacement (TKR have superior survival rates over uncemented components. The evidence is not clear regarding a cruciate sacrificing versus retaining in TKR, but a cruciate sacrificing component limits the risk early instability and potential revision. Patella resurfacing as part of a TKR is associated with improved outcomes. The results of total ankle replacement remain inferior to THR and TKR. RA patients achieve equivalent pain relief, but their rehabilitation is slower and their functional outcome is not as good. However, the key to managing these complicated patients is to work as part of a multidisciplinary team to optimise their outcome.

  6. Dilemmas in Uncemented Total Hip Arthroplasty

    NARCIS (Netherlands)

    Goosen, J.H.M.

    2009-01-01

    In this thesis, different aspects that are related to the survivorship and clinical outcome in uncemented total hip arthroplasty are analysed. In Chapter 2, the survival rate, Harris Hip score and radiographic features of a proximally hydroxyapatite coated titanium alloy femoral stem (Bi-Metric, Bio

  7. Knee Arthroplasty: With or Without Patellar Component?

    Directory of Open Access Journals (Sweden)

    Árpád Sólyom

    2015-09-01

    Full Text Available Arthroplasty is used when there is irreversible damage to the articular cartilage of the knee. It involves implanting a bicompartimental (femoral and tibial components or a tricompartimental (femoral, tibial and patellar components prosthesis. It is a very invasive and costly operation, so our objective was to evaluate the necessity of the patellar component.

  8. Periprosthetic osteolysis after total wrist arthroplasty

    DEFF Research Database (Denmark)

    Boeckstyns, Michel E H; Herzberg, Guillaume

    2014-01-01

    Background and Literature Review Periprosthetic osteolysis (PPO) after second- or third-generation total wrist arthroplasty (TWA), with or without evident loosening of the implant components, has previously been reported in the literature, but rarely in a systematic way. Purpose The purpose of th...

  9. Hip and knee arthroplasty: quo vadis?

    NARCIS (Netherlands)

    Ho, J.; Meis, J.F.G.M.; Nabuurs-Franssen, M.H.; Voss, A.

    2015-01-01

    Despite of the steady decrease of surgical site infection (SSI) over the last two decades, the incidence of SSI after hip and knee arthroplasty has recently surged. This may be explained by technical changes that may result in an increased risk of SSI, such as the broad implementation of fast track

  10. Knee arthroplasty: are patients' expectations fulfilled?

    DEFF Research Database (Denmark)

    Nilsdotter, Anna K; Toksvig-Larsen, Sören; Roos, Ewa

    2009-01-01

    to pain and physical function after knee arthroplasty. PATIENTS AND METHODS: 102 patients (39 men) with knee osteoarthritis and who were assigned for TKR (mean age 71 (51-86) years) were investigated with KOOS, SF-36, and additional questions concerning physical activity level, expectations...

  11. Fast-track revision knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B;

    2011-01-01

    Abstract Background and purpose Fast-track surgery has reduced the length of hospital stay (LOS), morbidity, and convalescence in primary hip and knee arthroplasty (TKA). We assessed whether patients undergoing revision TKA for non-septic indications might also benefit from fast-track surgery...

  12. Neurovascular lesion after total hip arthroplasty in congenital hip dysplasia: Case report

    Directory of Open Access Journals (Sweden)

    Stojković-Jovanović Tatjana

    2013-01-01

    Full Text Available Introduction. Nowadays, the total hip arthroplasty is a very frequent surgical intervention. In some cases, vascular and nerve injuries may happen around the hip with total hip arthroplasty. Although they are very rare, they may be very dangerous for the patient in some cases. This paper presents a case of a female patient, in whom the nervous fibularis lesion was detected after the total hip arthroplasty, and the occlusion of the iliac femoral artery was revealed later during physical therapy. Case Report. We described a case of a 32-year-old female patient, in whom the nervous fibularis lesion was detected after the total hip arthroplasty. The patient was referred to a ward for physical therapy. On the 19th postoperative day, she felt a vigorous ache and numbness on the left operated leg during stimulation of the paretic fibular musculature. Clinically weak inguinal arterial pulse was detected. After the examination, iliac-femoral occlusion was diagnosed. The patient was referred to the vascular surgeon. In the next few months, she was treated conservatively and eventually underwent surgery. The revascularization was achieved with a satisfactory effect. A year after the total hip replacement, the patient continued with rehabilitation and physical treatment, which lasted one and a half month and had an incomplete functional result - the patient walked with a walking stick and had weak fibular musculature of a severe degree. The vascular status of the leg was good. Conclusion. In this case, neurovascular lesions led to an incomplete functional recovery of the patient and compromised the expected treatment outcome. According to the scoring system used to assess the functionality, the result was marked as poor.

  13. Synovial cutaneous fistula complicating a reverse total shoulder arthroplasty.

    Science.gov (United States)

    Letter, Haley P; Limback, Joseph; Wasyliw, Christopher; Bancroft, Laura; Scherer, Kurt

    2016-06-01

    Reverse total shoulder arthroplasty is becoming a common form of shoulder arthroplasty that is often performed in the setting of rotator cuff pathology. Infection is a rare complication but is more common in reverse total shoulder arthroplasty than in hemiarthroplasty or anatomic total shoulder arthroplasty. We present the case of a 69-year-old patient with a reverse total shoulder arthroplasty who presented with purulent drainage from the skin of his anterior shoulder. Computed tomography arthrogram confirmed the presence of a synovial cutaneous fistula. Synovial cutaneous fistula is a rare variant of periprosthetic infection that, to our knowledge, has not been described previously in the setting of a reverse total shoulder arthroplasty. Computed tomography arthrogram proved to be a reliable method for confirming the diagnosis and was used for operative planning to remove the hardware. PMID:27257460

  14. Complications Related to Metal-on-Metal Articulation in Trapeziometacarpal Joint Total Joint Arthroplasty

    OpenAIRE

    Christina Frølich; Torben Bæk Hansen

    2015-01-01

    Adverse reactions to metal-on-metal (MoM) prostheses are well known from total hip joint resurfacing arthroplasty with elevated serum chrome or cobalt, pain and pseudo tumor formation. It may, however, also be seen after total joint replacement of the trapeziometacarpal joint using MoM articulation, and we present two cases of failure of MoM prostheses due to elevated metal-serum levels in one case and pseudo tumor formation in another case. Furthermore, we suggest a diagnostic algorithm for ...

  15. Unfractionated heparin and mechanical thromboprophylaxis in hip arthroplasty

    OpenAIRE

    Garcia, Flávio Luís; Marins, Murilo Humberto Tobias; Raddi, Thiago Bortoletto; Picado, Celso Hermínio Ferraz

    2015-01-01

    OBJECTIVE: To evaluate the efficacy and safety of unfractionated heparin associated with mechanical prophylaxis as a method for preventing venous thromboembolism in hip arthroplasty. METHOD: We retrospectively reviewed the records of 181 hip arthroplasties out of 216 consecutive cases performed over a period of 39 months in our hospital. We excluded 35 cases due to non-adherence to the standardized method of thromboprophylaxis or loss to follow-up. All arthroplasties evaluated completed one-y...

  16. The Results of ulnohumeral arthroplasty in elbow osteoarthritis

    OpenAIRE

    Dehghani, M.; E. Rouzbahani

    2008-01-01

    AbstractBackground and Purpose: Osteoarthritis (OA) of elbow is not common but can be disabling, if it is not responding to non-operative methods. Several surgical methods are suggested (joint debridment, ulnohumeral arthroplasty, fusion and total elbow arthroplasty). In this study, we evaluated the result of ulnohumeral arthroplasty in seven patients.Materials and Methods: Seven patients (5 males and 2 females) mean age 46 years of age (56-43), during 1378-1385 were operated on with the same...

  17. Revision Total Hip Replacement: A Case Report

    Directory of Open Access Journals (Sweden)

    Md Hafizur Rahman

    2013-07-01

    Full Text Available Total hip replacement is a reconstructive procedure that has improved the management of those diseases of the hip joint that have responded poorly to conventional medical therapy. Conventional, primary total hip replacement is a durable operation in the majority of patients. A hip replacement is a mechanical device with parts that are assembled before and during the operation. But the possible complications of total hip arthroplasty, and its clinical performance over time, is a challenging occasion to the surgeons, and such a challenge we faced with our presenting patient. A 68 year old lady with history of cemented bipolar hemiarthroplasty done in a tertiary care hospital, due to fracture neck of the left femur having the history of diabetes, chronic kidney disease, heart disease, anaemia, and mental disorders presented with loosened prosthesis, thinning of medial proximal cortex of the femur which had broken within few months after surgery. She complained of painful walking at left hip joint. There was also evidence of chronic infective and degenerative arthritis of acetabular component of the affected hip joint. Cemented revision total hip replacement surgery was performed with expert multidisciplinary involvement. On 2nd postoperative day the patient was allowed to walk on operated limb with the aid of walker. On 12th postoperative day all the stitches were removed and wound was found healthy.

  18. Qualifying CT for wrist arthroplasty: extending techniques for total hip arthroplasty to total wrist arthroplasty

    Science.gov (United States)

    Alcala, Yvonne; Olivecrona, Henrik; Olivecrona, Lotta; Noz, Marilyn E.; Maguire, Gerald Q., Jr.; Zeleznik, Michael P.; Sollerman, Christer

    2005-04-01

    The purpose of this study was to extend previous work to detect migration of total wrist arthroplasty non-invasively, and with greater accuracy. Two human cadaverous arms, each with a cemented total wrist implant, were used in this study. In one of the arms, 1 mm tantalum balls were implanted, six in the carpal bones and five in the radius. Five CT scans of each arm were acquired, changing the position of the arm each time to mimic different positions patients might take on repeated examinations. Registration of CT volume data sets was performed using an extensively validated, 3D semi-automatic volume fusion tool in which co-homologous point pairs (landmarks) are chosen on each volume to be registered. Three sets of ten cases each were obtained by placing landmarks on 1) bone only (using only arm one), 2) tantalum implants only, and 3) bone and tantalum implants (both using only arm two). The accuracy of the match was assessed visually in 2D and 3D, and numerically by calculating the distance difference between the actual position of the transformed landmarks and their ideal position (i.e., the reference landmark positions). All cases were matched visually within one width of cortical bone and numerically within one half CT voxel (0.32 mm, p = 0.05). This method matched only the bone/arm and not the prosthetic component per se, thus making it possible to detect prosthetic movement and wear. This method was clinically used for one patient with pain. Loosening of the carpal prosthetic component was accurately detected and this was confirmed at surgery.

  19. Double dislocation of finger interphalangeal joints

    OpenAIRE

    Jahangiri, Saqib Aziz; Mestha, Prabhakar; McNally, Scarlett

    2012-01-01

    A 62-year-old, right-hand-dominant man who had dementia and lived in an Elderly Mentally Infirm (EMI) nursing home was admitted through Accident & Emergency (A&E) department following unwitnessed injury to the left little finger.

  20. Arthroplasty of the rheumatoid hand. Pre- and postoperative imaging with special consideration of biomechanical and pathobiomechanical aspects and its radiological evaluation

    International Nuclear Information System (INIS)

    Radiology plays a key role when the indications for arthroplasties of the hand and finger joints are determined and for the postoperative follow-up. On the one hand, the degree of inflammatory changes in all affected compartments is to be evaluated and graded; on the other hand, conventional radiograms allow for a first assessment of possible joint instability and impaired biomechanics. Both aspects influence the choice of the proper surgical therapeutic strategy. Osteolysis, deformity, fracture, prosthesis loosening or failure, heterotopic ossification, and foreign body-associated formation of granulation tissue are complications which can be detected on follow-up radiographs early on. (orig.)

  1. Stainless steel quadralatch finger test report

    International Nuclear Information System (INIS)

    The design of the quadralatch on the universal samplers was changed in response to flammable gas operating constraints. Additional redesign of the fingers was included to facilitate manufacturability. The new design was tested to assure satisfactory performance. It was shown that the fingers can hold a sampler in place with an upward force of at least 2200 N (500 pounds) and that the mechanical remote latch unit can release the quadralatch under this condition of maximum upward force

  2. Surface tension and dynamics of fingering patterns

    OpenAIRE

    Magdaleno, F. X.; Casademunt, J.

    1997-01-01

    We study the minimal class of exact solutions of the Saffman-Taylor problem with zero surface tension, which contains the physical fixed points of the regularized (non-zero surface tension) problem. New fixed points are found and the basin of attraction of the Saffman-Taylor finger is determined within that class. Specific features of the physics of finger competition are identified and quantitatively defined, which are absent in the zero surface tension case. This has dramatic consequences f...

  3. COMPARION OF GAP ARTHROPLASTY AND INTERPOSITIONAL GAP ARTHROPLASTY ON THE TEMPOROMANDIBULAR JOINT ANKYLOSIS

    Directory of Open Access Journals (Sweden)

    M. Ramezanian T. Yavary

    2006-11-01

    Full Text Available Temporomandibular joint ankylosis causes limitation in mouth opening and establishes severe deformity and asymmetry in patient’s face, especially in children. Surgery is the only treatment. This study was conducted to compare the effect of two surgical approaches, gap arthropasty and interpositional gap arthroplasty, on rate of maximum interincisal opening in temporomandibular joint ankylosis. We also evaluated the relapse rate of these two surgical approaches. A total of 48 patients were enrolled in this cross-sectional experimental study. Range of mouth opening was evaluated before and during and one year after surgery. All other related information was also recorded. Mean age of the study population was 19.5  8.9 years. Of those, 21 (41% were male and 27 (59% were female. For 26 patients (54.2% interpositional gap arthroplasty was accomplished and for 22 patients (45.8% gap arthropasty was performed. Mean range of mouth opening before and after surgery was 10.3  3.9 and 33.9  5.2 in interpositional gap arthroplasty, 8.7  4.9 and 32.1  7.8 in gap arthropasty, respectively. The results showed that the range of mouth opening significantly increases after ankylosis surgery in both surgical approaches but improvement was less in interpositional gap arthroplasty. In regards to recurrence, results of interpositional gap arthroplasty were superior to gap arthropasty.

  4. Finger Search in the Implicit Model

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Nielsen, Jesper Asbjørn Sindahl; Truelsen, Jakob

    2012-01-01

    We address the problem of creating a dictionary with the finger search property in the strict implicit model, where no information is stored between operations, except the array of elements. We show that for any implicit dictionary supporting finger searches in q(t) = Ω(logt) time, the time to move...... the finger to another element is Ω(q− 1(logn)), where t is the rank distance between the query element and the finger. We present an optimal implicit static structure matching this lower bound. We furthermore present a near optimal implicit dynamic structure supporting search, change-finger, insert......, and delete in times $\\mathcal{O}(q(t))$, $\\mathcal{O}(q^{-1}(\\log n)\\log n)$, $\\mathcal{O}(\\log n)$, and $\\mathcal{O}(\\log n)$, respectively, for any q(t) = Ω(logt). Finally we show that the search operation must take Ω(logn) time for the special case where the finger is always changed to the element...

  5. Finger multibiometric cryptosystems: fusion strategy and template security

    Science.gov (United States)

    Peng, Jialiang; Li, Qiong; Abd El-Latif, Ahmed A.; Niu, Xiamu

    2014-03-01

    We address two critical issues in the design of a finger multibiometric system, i.e., fusion strategy and template security. First, three fusion strategies (feature-level, score-level, and decision-level fusions) with the corresponding template protection technique are proposed as the finger multibiometric cryptosystems to protect multiple finger biometric templates of fingerprint, finger vein, finger knuckle print, and finger shape modalities. Second, we theoretically analyze different fusion strategies for finger multibiometric cryptosystems with respect to their impact on security and recognition accuracy. Finally, the performance of finger multibiometric cryptosystems at different fusion levels is investigated on a merged finger multimodal biometric database. The comparative results suggest that the proposed finger multibiometric cryptosystem at feature-level fusion outperforms other approaches in terms of verification performance and template security.

  6. Artificial cervical disc replacement: Principles, types and techniques

    Directory of Open Access Journals (Sweden)

    Sekhon L

    2005-01-01

    Full Text Available Cervical arthroplasty after anterior decompression with insertion of a prosthetic total disc replacement has been suggested as an alternate to anterior cervical fusion. Currently there are four cervical arthroplasty devices available on the market whose results in clinical use have been reported. Each device varies in terms of materials, range of motion, insertion technique and constraint. It is not known which device is ideal. Early studies suggest that in the short term, the complication rate and efficacy is no worse than fusion surgery. Long-term results have not yet been reported. This review examines the current prostheses available on the market as well as discussing issues regarding indications and technique. Pitfalls are discussed and early experiences reviewed. In time, it is hoped that a refinement of cervical arthroplasty occurs in terms of both materials and design as well as in terms of indications and clinical outcomes as spinal surgeons enter a new era of the management of cervical spine disease.

  7. Cervical motion segment replacement

    OpenAIRE

    Bryan, Vincent E.

    2002-01-01

    When symptoms bring to light a cervical spine degenerative disc process that requires surgical intervention, a symptom relieving procedure such as decompression, followed by functional restoration, arthroplasty, offers the benefit of prophylaxis of accelerated spondylosis at the operated level. In addition, by altering the biomechanical stress factors at adjacent levels, theoretically it should offer prophylactic benefit at these levels as well. The design requirements for a cervical disc pro...

  8. Cost Analysis in Shoulder Arthroplasty Surgery

    Directory of Open Access Journals (Sweden)

    Matthew J. Teusink

    2012-01-01

    Full Text Available Cost in shoulder surgery has taken on a new focus with passage of the Patient Protection and Affordable Care Act. As part of this law, there is a provision for Accountable Care Organizations (ACOs and the bundled payment initiative. In this model, one entity would receive a single payment for an episode of care and distribute funds to all other parties involved. Given its reproducible nature, shoulder arthroplasty is ideally situated to become a model for an episode of care. Currently, there is little research into cost in shoulder arthroplasty surgery. The current analyses do not provide surgeons with a method for determining the cost and outcomes of their interventions, which is necessary to the success of bundled payment. Surgeons are ideally positioned to become leaders in ACOs, but in order for them to do so a methodology must be developed where accurate costs and outcomes can be determined for the episode of care.

  9. Thromboembolism prophylaxis practices in orthopaedic arthroplasty patients.

    LENUS (Irish Health Repository)

    Cawley, D

    2010-10-01

    Thromboembolic events are a post-operative complication of arthroplasty surgery for up to 3 months. The incidence however, is not fully known. Some form of prophylaxis should be provided to all arthroplasty patients. Clinicians are wary of side effects, compliance profile and the associated cost. The objective of this study is to investigate practice patterns and their relevance to 3 risk groups. Ninety questionnaires were sent to orthopaedic surgeons with 3 hypothetical clinical scenarios and 10 prophylaxis regimes for thromboembolism across different risk groups. The response rate was 81\\/90 (90%). The most popular options in all 3 cases were early mobilisation, thrombo-embolism deterrant (TED) stockings and low molecular weight heparin (LMWH) (51\\/81, 62% of all cases). An inconsistent relationship exists between preferred practice and relevant guidelines. Preferred practice does not correlate with each level of risk.

  10. Fast-track revision knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B; Kehlet, Henrik

    2011-01-01

    Abstract Background and purpose Fast-track surgery has reduced the length of hospital stay (LOS), morbidity, and convalescence in primary hip and knee arthroplasty (TKA). We assessed whether patients undergoing revision TKA for non-septic indications might also benefit from fast-track surgery....... Methods 29 patients were operated with 30 revision arthroplasties. Median age was 67 (34-84) years. All patients followed a standardized fast-track set-up designed for primary TKA. We determined the outcome regarding LOS, morbidity, mortality, and satisfaction. Results Median LOS was 2 (1-4) days...... undergoing revision TKA for non-septic reasons may be included in fast-track protocols. Outcome appears to be similar to that of primary TKA regarding LOS, morbidity, and satisfaction. Our findings call for larger confirmatory studies and studies involving other indications (revision THA, 1-stage septic...

  11. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Directory of Open Access Journals (Sweden)

    Gavaskar Ashok S

    2012-12-01

    Full Text Available 【Abstract】Total hip arthroplasty (THA for an un-treated acetabular fracture is technically challenging and the long-term result is not so favorable. A 45-year-old fe-male patient with untreated column and comminuted poste-rior wall fracture of the acetabulum was treated in our insti-tution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior col-umn with cancellous grafting and cementless THA in a single stage. At 3 years’ follow-up, the patient was independently mobile without limb length discrepancy. Radiological evalu-ation showed well integrated components and bone grafts. No evidence of aseptic loosening or osteolysis was found. This report aims to emphasize that bony acetabular recon-struction allows the use of primary hip components, which improves prosthesis longevity and preserves bone stock for a future revision. Key words: Acetabulum; Fractures, bone; Hip dislocation; Arthroplasty, replacement, hip

  12. Imaging of hip arthroplasty; Bildgebung bei Hueftprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, M.J. [Abteilung fuer Osteologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Klinische Abteilung fuer Radiodiagnostik chirurgischer Faecher, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Ludwig-Boltzmann-Institut fuer Radiologische Tumordiagnostik, Wien (Austria); Mayerhoefer, M. [Klinische Abteilung fuer Radiodiagnostik chirurgischer Faecher, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Gottsauner-Wolf, F. [Universitaetsklinik fuer Orthopaedie, Wien (Austria); Abteilung fuer Orthopaedie, Allgemeines oeffentliches KH, Krems (Austria); Krestan, C.; Imhof, H. [Abteilung fuer Osteologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Toma, C.D. [Universitaetsklinik fuer Orthopaedie, Wien (Austria)

    2002-06-01

    Hip arthroplasty has become a common and still increasing procedure for the treatment of osteoarthritis, advanced head necrosis, post-inflammatory arthritis or rheumatoid arthritis.Radiography is the most important imaging modality for monitoring the normal, asymptomatic hip arthroplasty. Radiographs are obtained at the end of a surgical treatment, to exclude complications like fracture or component misplacement. In the follow-up radiographs are used for the diagnosis of loosening and infection of the hip arthroplasty as well as soft tissue ossification. Together with the history and clinical information, the analysis of morphological findings allows to find the grade of loosening. MRI has been advocated in the diagnosis of infection, in particular in the localisation of soft tissue involvement.Imaging, especially by radiographs, is used for the evaluation of the normal and complicated follow-up of hip arthroplasty. (orig.) [German] Die Implantation einer Hueftgelenkprothese ist eine immer haeufiger verwendete medizinische Massnahme bei Erkrankungen des Hueftgelenks wie Koxarthrose, Hueftkopfnekrose, postentzuendliche Arthrose oder rheumatoide Arthritis.Von den bildgebenden Methoden ist das konventionelle Roentgen die wichtigste Untersuchung, um den normalen Behandlungsverlauf einer Hueftprothese zu monitieren. Das Roentgen kann fruehzeitige Komplikationen wie Fraktur oder Fehlposition intraoperativ oder eine Luxation postoperativ erfassen. Im laengerfristigen Verlauf ist das Roentgen zur Diagnose von Infektion, Prothesenlockerung und Weichteilverknoecherung geeignet. In Zusammenschau mit der Klinik ermoeglicht die Analyse morphologisch-radiologischer Details, die Wahrscheinlichkeit einer Lockerung abzuschaetzen. Bei Protheseninfektionen ermoeglicht die MRT die Lokalisation von Weichteilentzuendungen.Die Methoden der Bildgebung, besonders das Roentgen, haben in der Beurteilung des normalen und in der Diagnose des komplizierten Verlaufes einen hohen Stellenwert

  13. Infected total knee arthroplasty treatment outcome analysis

    OpenAIRE

    Radoičić Dragan; Popović Zoran; Barjaktarović Radoslav; Marinković Jugoslav

    2012-01-01

    Background/Aim. Infected total knee arthroplasty (TKA) is a topic of great importance, because its diagnosing and treatment requires a lot of resources, and often has an unsatisfactory outcome. The aim of this study was to analyze the outcome of the treatment of infection developed following TKA. Methods. This retrospective study of infected TKAs was performed in the period from 1998 to 2008 in the Orthopedics & Traumatology Clinic of the Military Medical Academy (MMA) in Belgrade. ...

  14. Future Bearing Surfaces in Total Hip Arthroplasty

    OpenAIRE

    Chang, Jun-Dong

    2014-01-01

    One of the most important issues in the modern total hip arthroplasty (THA) is the bearing surface. Extensive research on bearing surfaces is being conducted to seek an ideal bearing surface for THA. The ideal bearing surface for THA should have superior wear characteristics and should be durable, bio-inert, cost-effective, and easy to implant. However, bearing surfaces that are currently being implemented do not completely fulfill these requirements, especially for young individuals for whom...

  15. Ultrafast High-Resolution Mass Spectrometric Finger Pore Imaging in Latent Finger Prints

    Science.gov (United States)

    Elsner, Christian; Abel, Bernd

    2014-11-01

    Latent finger prints (LFPs) are deposits of sweat components in ridge and groove patterns, left after human fingers contact with a surface. Being important targets in biometry and forensic investigations they contain more information than topological patterns. With laser desorption mass spectrometry imaging (LD-MSI) we record `three-dimensional' finger prints with additional chemical information as the third dimension. Here we show the potential of fast finger pore imaging (FPI) in latent finger prints employing LD-MSI without a classical matrix in a high- spatial resolution mode. Thin films of gold rapidly sputtered on top of the sample are used for desorption. FPI employing an optical image for rapid spatial orientation and guiding of the desorption laser enables the rapid analysis of individual finger pores, and the chemical composition of their excretions. With this approach we rapidly detect metabolites, drugs, and characteristic excretions from the inside of the human organism by a minimally-invasive strategy, and distinguish them from chemicals in contact with fingers without any labeling. The fast finger pore imaging, analysis, and screening approach opens the door for a vast number of novel applications in such different fields as forensics, doping and medication control, therapy, as well as rapid profiling of individuals.

  16. Postero-Lateral Disc Prosthesis Combined With a Unilateral Facet Replacement Device Maintains Quantity and Quality of Motion at a Single Lumbar Level

    OpenAIRE

    Nayak, Aniruddh N.; Doarn, Michael C.; Gaskins, Roger B.; James, Chris R.; Cabezas, Andres F.; Castellvi, Antonio E.; Santoni, Brandon G.

    2014-01-01

    Background Mechanically replacing one or more pain generating articulations in the functional spinal unit (FSU) may be a motion preservation alternative to arthrodesis at the affected level. Baseline biomechanical data elucidating the quantity and quality of motion in such arthroplasty constructs is non-existent. Purpose The purpose of the study was to quantify the motion-preserving effect of a posterior total disc replacement (PDR) combined with a unilateral facet replacement (FR) system at ...

  17. Clinical effects of applying a tourniquet in total knee arthroplasty on blood loss

    Institute of Scientific and Technical Information of China (English)

    ZHANG Fu-jiang; XIAO Yu; LIU Ya-bin; TIAN Xu; GAO Zhi-guo

    2010-01-01

    Background Tourniquets used during total knee arthroplasty may lead to many complications. The aim of this study was to determine perioperative blood loss and its clinical relevance in total knee replacement surgery after applying a tourniquet.Methods From June 2009 to October 2009, 60 consecutive patients who underwent routine total knee arthroplasty were randomly divided into two groups and were treated with or without a tourniquet (30 patients/group). There were no significant differences in patient baseline characteristics between the two groups. We compared the two groups of patients in terms of intra- and postoperative bleeding, invisible or visible bleeding, and total blood loss.Results None of the patients showed poor wound healing, lower extremity deep venous thrombosis or other complications. The amount of blood loss during surgery was lower in the tourniquet group than in the control group (P<0.01). However, postoperative visible bleeding (P <0.05) and occult bleeding (P <0.05) were significantly greater in the toumiquet group than in the control group. There was no significant difference in the total amount of blood loss between the two groups (P >0.05).Conclusions Tourniquet can reduce bleeding during total knee replacement surgery, but is associated with greater visible and invisible blood loss.

  18. Joint Replacement Surgery

    Science.gov (United States)

    ... a Clinical Trial Journal Articles Arthritis July 2014 Joint Replacement Surgery: Health Information Basics for You and Your Family What Is Joint Replacement Surgery? Joint replacement surgery is removing a ...

  19. MedlinePlus: Knee Replacement

    Science.gov (United States)

    ... Knee Pain and the Weekend Warriors (OR-Live) - Mercy Hospital, Miami, FL, 3/17/2009 Also in ... 2012 Small Incision Total Knee Arthroplasty (OR-Live) - Mercy Hospital, Miami, FL, 3/01/2011 Also in ...

  20. Saffman-Taylor fingers with kinetic undercooling

    KAUST Repository

    Gardiner, Bennett P. J.

    2015-02-23

    © 2015 American Physical Society. The mathematical model of a steadily propagating Saffman-Taylor finger in a Hele-Shaw channel has applications to two-dimensional interacting streamer discharges which are aligned in a periodic array. In the streamer context, the relevant regularization on the interface is not provided by surface tension but instead has been postulated to involve a mechanism equivalent to kinetic undercooling, which acts to penalize high velocities and prevent blow-up of the unregularized solution. Previous asymptotic results for the Hele-Shaw finger problem with kinetic undercooling suggest that for a given value of the kinetic undercooling parameter, there is a discrete set of possible finger shapes, each analytic at the nose and occupying a different fraction of the channel width. In the limit in which the kinetic undercooling parameter vanishes, the fraction for each family approaches 1/2, suggesting that this "selection" of 1/2 by kinetic undercooling is qualitatively similar to the well-known analog with surface tension. We treat the numerical problem of computing these Saffman-Taylor fingers with kinetic undercooling, which turns out to be more subtle than the analog with surface tension, since kinetic undercooling permits finger shapes which are corner-free but not analytic. We provide numerical evidence for the selection mechanism by setting up a problem with both kinetic undercooling and surface tension and numerically taking the limit that the surface tension vanishes.

  1. Perceiving fingers in single-digit arithmetic problems

    Directory of Open Access Journals (Sweden)

    Ilaria eBerteletti

    2015-03-01

    Full Text Available In this study, we investigate in children the neural underpinnings of finger representation and finger movement involved in single-digit arithmetic problems. Evidence suggests that finger representation and finger-based strategies play an important role in learning and understanding arithmetic. Because different operations rely on different networks, we compared activation for subtraction and multiplication problems in independently localized finger somatosensory and motor areas and tested whether activation was related to skill. Brain activations from children between 8 and 13 years of age revealed that only subtraction problems significantly activated finger motor areas, suggesting reliance on finger-based strategies. In addition, larger subtraction problems yielded greater somatosensory activation than smaller problems, suggesting a greater reliance on finger representation for larger numerical values. Interestingly, better performance in subtraction problems was associated with lower activation in the finger somatosensory area. Our results support the importance of fine-grained finger representation in arithmetical skill and are the first neurological evidence for a functional role of the somatosensory finger area in proficient arithmetical problem solving, in particular for those problems requiring quantity manipulation. From an educational perspective, these results encourage investigating whether different finger-based strategies facilitate arithmetical understanding and encourage educational practices aiming at integrating finger representation and finger-based strategies as a tool for instilling stronger numerical sense.

  2. Clostridium difficile-associated diarrhoea in primary joint arthroplasty in Aneurin Bevan University Health Board South.

    Science.gov (United States)

    Blocker, O; Abdulkadir, U; Roberts, P

    2016-03-01

    Introduction The choice of perioperative antibiotics to reduce the prevalence of infection after joint arthroplasty should be considered carefully to minimise the risk of nosocomial infections. Dramatic increases in the incidence and severity of healthcare-associated Clostridium difficile infection with Clostridium difficile-associated diarrhoea (CDAD) have occurred since 2000. Methods A retrospective audit of patients who underwent total hip and total knee replacement between 1 January 2005 and 31 December 2007 was undertaken in Aneurin Bevan University Health Board South (ABHBS). Stool samples from patients who had diarrhoea audit linked joint-replacement patients between 1 July 2010 and 26 June 2013 with infection control-records for CDAD-positive cases. Results In the first audit cycle, 1900 joint procedures were carried out in 1845 patients. There were 4 cases of CDAD audit period, 2591 joint procedures were undertaken in 2400 patients: no cases of CDAD financial savings in antibiotics and nursing hours. PMID:26836055

  3. A reverse flow cross finger pedicle skin flap from hemidorsum of finger.

    Science.gov (United States)

    Mishra, Satyanarayan; Manisundaram, S

    2010-04-01

    A reverse-flow cross-finger pedicle skin flap raised from the hemidorsum has been used, which is a modification of the distally based dorsal cross-finger flap. The flap is raised from the hemidorsum at a plane above the paratenon, the distal-most location of the base being at the level of the distal interphalangeal joint. Thirty-two flaps were used from as many fingers of as many patients. Of these, 31 (97%) flaps survived fully; there was stiffness of finger in one (3%) patient and the two-point discrimination was 4-8mm (n=14). Follow-up period was 2 months to 3 years, the median being 1 year and 3 months. The advantages of this flap are that there is less disruption of veins and less visible disfigurement of the dorsum of the finger when compared to other pedicled cross-finger skin flaps. The disadvantage of this flap is its restricted width. It is recommended as the cross-finger pedicle skin flap of choice when the defect is not wide. PMID:19386561

  4. Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties

    International Nuclear Information System (INIS)

    After implantation of a metal-on-metal total hip arthroplasty (MoM THA), a large incidence of pseudotumor formation has been described recently. Several centers have invited patients for follow-up in order to screen for pseudotumor formation. The spectrum of abnormalities found by CT in MoM THA patients can be unfamiliar to radiologists and orthopedic surgeons. Previously, a CT five-point grading scale has been published. In this paper, a simplification into a three-point classification system gives insight in the morphological distinction of abnormalities of the postoperative hip capsule in MoM implants in relation to the decision for revision. The reliability of this simplified classification regarding intra- and interrater reliability and its association with revision rate is investigated and discussed. All patients who underwent MoM THA in our hospital were invited for screening. Various clinical measures and CT scan were obtained in a cross-sectional fashion. A decision on revision surgery was made shortly after screening. CT scans were read in 582 patients, of which 82 patients were treated bilaterally. CT scans were independently single read by two board-certified radiologists and classified into categories I-V. In a second meeting, consensus was obtained. Categories were subsequently rubricated in class A (categories I and II), B (category III), and C (categories IV and V). Intra- and inter-radiologist agreement on MoM pathology was assessed by means of the weighted Cohen's kappa. Categorical data were presented as n (%), and tested by means of Fisher's exact test. Continuous data were presented as median (min-max) and tested by means of Mann-Whitney U test (two group comparison) or Kruskal-Wallis test (three group comparison). Logistic regression analysis was performed in order to study independence of CT class for association with revision surgery. Univariate statistically significant variables were entered in a multiple model. All statistical

  5. Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties

    Energy Technology Data Exchange (ETDEWEB)

    Boomsma, Martijn F.; Warringa, Niek [Isala Hospital, Department of Radiology, Zwolle (Netherlands); Edens, Mireille A. [Isala Hospital, Department of Innovation and Science, Zwolle (Netherlands); Lingen, Christiaan P. van; Ettema, Harmen B.; Verheyen, Cees C.P.M. [Isala Hospital, Department of Orthopaedics, Zwolle (Netherlands); Maas, Mario [AMC, Department of Radiology, Amsterdam (Netherlands)

    2015-08-15

    After implantation of a metal-on-metal total hip arthroplasty (MoM THA), a large incidence of pseudotumor formation has been described recently. Several centers have invited patients for follow-up in order to screen for pseudotumor formation. The spectrum of abnormalities found by CT in MoM THA patients can be unfamiliar to radiologists and orthopedic surgeons. Previously, a CT five-point grading scale has been published. In this paper, a simplification into a three-point classification system gives insight in the morphological distinction of abnormalities of the postoperative hip capsule in MoM implants in relation to the decision for revision. The reliability of this simplified classification regarding intra- and interrater reliability and its association with revision rate is investigated and discussed. All patients who underwent MoM THA in our hospital were invited for screening. Various clinical measures and CT scan were obtained in a cross-sectional fashion. A decision on revision surgery was made shortly after screening. CT scans were read in 582 patients, of which 82 patients were treated bilaterally. CT scans were independently single read by two board-certified radiologists and classified into categories I-V. In a second meeting, consensus was obtained. Categories were subsequently rubricated in class A (categories I and II), B (category III), and C (categories IV and V). Intra- and inter-radiologist agreement on MoM pathology was assessed by means of the weighted Cohen's kappa. Categorical data were presented as n (%), and tested by means of Fisher's exact test. Continuous data were presented as median (min-max) and tested by means of Mann-Whitney U test (two group comparison) or Kruskal-Wallis test (three group comparison). Logistic regression analysis was performed in order to study independence of CT class for association with revision surgery. Univariate statistically significant variables were entered in a multiple model. All statistical

  6. Autonomous control of multi-fingered hand

    Institute of Scientific and Technical Information of China (English)

    JIANG Li; LIU Hong

    2006-01-01

    This paper describes a novel autonomous control strategy of multi-fingered hand based on a modular control system of dexterous manipulation. A simple proportional-integral-derivative(PID) position control with friction compensation, which requires few friction parameters, is used to realize accurate and smooth trajectory tracking in pregrasp phase. In grasp and manipulation phases, an event-driven switcher is adopted to determine the switching between unconstrained position control and constrained torque control, and an improved explicit integral force control strategy is implemented to realize simultaneously stable contact transition and accurate force tracking. Experimental results have verified the effectiveness of the proposed autonomous control strategy of multi-fingered hand.

  7. Reliability and Validity of the Dutch Version of the International Physical Activity Questionnaire in Patients After Total Hip Arthroplasty or Total Knee Arthroplasty

    NARCIS (Netherlands)

    Blikman, Tim; Stevens, Martin; Bulstra, Sjoerd K.; van den Akker-Scheek, Inge; Reininga, Inge H. F.

    2013-01-01

    STUDY DESIGN: Psychometric assessment. OBJECTIVES: To determine test-retest reliability and concurrent validity of the International Physical Activity Questionnaire (IPAQ) in patients after total hip arthroplasty or total knee arthroplasty. BACKGROUND: Despite recognized benefits of regular physical

  8. Double-V block fingers with cruciform recess

    Science.gov (United States)

    Voellmer, George M.

    1993-01-01

    In a robot having a gripper including a pair of fingers and a drive motor for driving the fingers toward and away from one another while the fingers remain parallel to each other, the fingers consist of finger pads, which interface with a handle on an object to be grasped, and a shank, which attaches the fingers to the robot gripper. The double-V finger has two orthogonal V-grooves forming in the center of the finger pads and recessed cruciform. The double-V finger is used with a handle on the object to be grasped which is the negative of the finger pads. The handle face consists of V-shaped pads capped with a rectangular cruciform. As the gripper is brought into place near the handle, the finger pads are lined up facing the handle pads. When the finger pad and the handle pad are in proper alignment, the rectangular ridges on the handle fall inside the rectangular grooves on the finger, and the grip is complete.

  9. ANALYSIS WITH MSC ADAMS OF A 5-FINGER AND 3-PHALANX /FINGER UNDER-ACTUATEDMECHANICAL HAND

    Directory of Open Access Journals (Sweden)

    Gheorghe POPESCU

    2013-05-01

    Full Text Available This paper studies the analysis with MSC ADAMS of a 5-fingered and 3-phalanx/finger underactuatedmechanical hand, designed by the author to work on industrial robots. Moreover, in order to increasegrasping safety in the automated handling process, the author has fitted each finger with a locking sequence inthe final phase of grasping. Thus, the mechanism of mechanical hand is considered to be a mechanical systemand is treated like a set of rigid bodies connected by mechanical linkages and elastic elements. To model andsimulate this mechanism with MSC ADAMS programme, the author covered the following stages: constructionof the model, testing-simulation, validation, finishing, parameterization, and optimization

  10. Total disc replacement for chronic low back pain: background and a systematic review of the literature

    OpenAIRE

    de Kleuver, M.; F. Oner; W. Jacobs

    2002-01-01

    In this paper the rationale for total disc replacement is discussed, and the authors suggest seven requirements that should be met before the implantation of these devices can be accepted as regular procedures. In an attempt to answer the questions raised, a systematic literature search was performed. The search yielded no controlled trials and nine case series with a total of 564 arthroplasties in 411 patients. The devices used were SB Charité in eight and Acroflex in one study. The percenta...

  11. [Partial replacement of obsolete prosthetic implants].

    Science.gov (United States)

    Petit, R

    2005-10-01

    Thanks to better technique for cemented prostheses or to better osteointegration of porous coated implants, a long term survival can be expected for joint prostheses. Wear of the bearing surfaces resulting in osteolysis, metallosis and even rupture has become the main threat after several years. In such cases, revising all the parts of a stable and well fixed implant may cause fractures, loss of bone and thus need an extensive reconstruction. Revising only the worn out parts might be preferable, provided that they still are available. Data collected by the SFHG (French Hip and Knee Society) and AVIO group show that 45% of hip revisions and 16% of knee revisions are partial ones. The need for a total exchange instead of a partial one appeared in 6.4% of knee revisions and 2.8% of hip revisions, because parts were no longer available. These problems linked to a longer life expertancy of the patients and the increasing number of hip and knee arthroplasties will be met more and more often by orthopedic surgeons. When parts identical to the worn out ones are still on the market, there is no problem. When their production has been given up, but the company has kept their references and accepts to make a single element it may be possible to obtain the missing unit. The increased cost of such a fabrication, however is not nowadays supported by an appropriate price. But in a few remaining cases without enough industrial references, a custom-made part had to be done to allow partial replacement, with the benefit of an adapted price. Care must be taken to observe the regulations. The surgeon endorses full responsibility not only for the surgical procedure but also for the choice of the implanted device. For custom-made products he is responsible for the technical data given to the company. The patient must be thoroughly informed, and his opinion taken into account in the operative decision. As a revision arthroplasty aims at restoring a good function, the procedure should

  12. Outcomes of total hip arthroplasty, as a salvage procedure, following failed internal fixation of intracapsular fractures of the femoral neck:a systematic review and meta-analysis

    OpenAIRE

    Mahmoud, Samer; Pearse, Eyiyemi; Smith, Toby; Hing, Caroline

    2016-01-01

    The management of intracapsular femoral neck fractures in independently mobile patients remains controversial. Successful fixation obviates the limitations of arthroplasty for this group of patients, however with fixation failure rates as high as 30%, the outcome of revision surgery to salvage total hip replacement (THR) must be considered. We carried out this review to determine the outcome of salvage THR and how this compares to primary THR for fracture. We performed a PRISMA compliant syst...

  13. In vitro-analysis of kinematics and intradiscal pressures in cervical arthroplasty versus fusion – A biomechanical study in a sheep model with two semi-constrained prosthesis

    OpenAIRE

    Daentzer, Dorothea; Welke, Bastian; Hurschler, Christof; Husmann, Nathalie; Jansen, Christina; Flamme, Christian Heinrich; Richter, Berna Ida

    2015-01-01

    Background As an alternative technique to arthrodesis of the cervical spine, total disc replacement (TDR) has increasingly been used with the aim of restoration of the physiological function of the treated and adjacent motions segments. The purpose of this experimental study was to analyze the kinematics of the target level as well as of the adjacent segments, and to measure the pressures in the proximal and distal disc after arthrodesis as well as after arthroplasty with two different semi-c...

  14. Association between fixation technique and revision risk in total hip arthroplasty patients younger than 55 years of age. Results from the Nordic Arthroplasty Register Association

    DEFF Research Database (Denmark)

    Pedersen, A B; Mehnert, F; Havelin, L I;

    2014-01-01

    Objectives: To evaluate implant survival following primary total hip replacement (THR) in younger patients. To describe the diversity in use of cup-stem implant combinations. Design: 29,558 primary THRs osteoarthritis (OA) patients younger than 55 years of age performed from 1995 through 2011 were...... identified using the Nordic Arthroplasty Registry Association database. We estimated adjusted relative risk (aRR) of revision with 95% confidence interval (CI) using Cox regression. Results: In general, no difference was observed between uncemented and cemented implants in terms of risk of any revision...... uncemented and hybrid implants led to elevated risk of revision due to other causes, as well as elevated risk of revision due to any reason within 2 years. 183 different uncemented cup-stem implant combinations were registered in Denmark, of these, 172 were used in less than 100 operations which is similar...

  15. Testing of FTS fingers and interface using a passive compliant robot manipulator. [flight telerobot servicer

    Science.gov (United States)

    Nguyen, Charles C.; Antrazi, Sami S.

    1992-01-01

    This report deals with testing of a pair of robot fingers designed for the Flight Telerobotic Servicer (FTS) to grasp a cylinder type of Orbital Replaceable Unit (ORU) interface. The report first describes the objectives of the study and then the testbed consisting of a Stewart Platform-based manipulator equipped with a passive compliant platform which also serves as a force/torque sensor. Kinematic analysis is then performed to provide a closed-form solution for the force inverse kinematics and iterative solution for the force forward kinematics using the Newton's Raphson Method. Mathematical expressions are then derived to compute force/torques applied to the FTS fingers during the mating/demating with the interface. The report then presents the three parts of the experimental study on the feasibility and characteristics of the fingers. The first part obtains data of forces applied by the fingers to the interface under various misalignments, the second part determines the maximum allowable capture angles for mating, and the third part processes and interprets the obtained force/torque data.

  16. Acceleration Workspace of Cooperating Multi-Finger Robot Systems

    Institute of Scientific and Technical Information of China (English)

    Hyungwon Shim; Jihong Lee

    2008-01-01

    We present a mathematical method for acceleration workspace analysis of cooperating multi-finger robot systems using a model of point-contact with friction. A new unified formulation from dynamic equations of cooperating multi-finger robots is derived considering the force and acceleration relationships between the fingers and the object to be handled. From the dynamic equation, maximum translational and rotational acceleration bounds of an object are calculated under given constraints of contact conditions, configurations of fingers, and bounds on the torques of joint actuators for each finger. Here, the rotational acceleration bounds can be applied as an important manipulability index when the multi-finger robot grasps an object. To verify the proposed method, we used a set of case studies with a simple multi-finger mechanism system. The achievable acceleration boundary in task space can be obtained successfully with the proposed method and the acceleration boundary depends on the configurations of fingers.

  17. Effective Length Design of Humanoid Robot Fingers Using Biomimetic Optimization

    Directory of Open Access Journals (Sweden)

    Byoung-Ho Kim

    2015-10-01

    Full Text Available In this study, we propose an effective design method for the phalangeal parameters and the total size of humanoid robot fingers based on a biomimetic optimization. For the optimization, an interphalangeal joint coordination parameter and the length constraints inherent in human fingers are considered from a biomimetic perspective. A reasonable grasp formulation is also taken into account from the viewpoint of power grasping, where the grasp space of a humanoid robot finger is importantly considered to determine the phalangeal length parameters. The usefulness of the devised biomimetic optimization method is shown through the design examples of various humanoid robot fingers. In fact, the optimization-based finger design method enables us to determine effectively the proper phalangeal size of humanoid robot fingers for human-like object handling tasks. In addition, we discuss its contribution to the structural configuration and coordinated motion of a humanoid robot finger, and address its practical availability in terms of effective finger design.

  18. Evaluation of endothelial function using finger plethysmography

    OpenAIRE

    2009-01-01

    Evaluation of endothelial function using finger plethysmography A. K. Faizi, D. W. Kornmo and S. Agewall Department of Medicine, Aker University Hospital and Oslo University, Oslo, Norway Correspondence to Stefan Agewall, Department of Medicine, Aker University Hospital and Oslo University, 0514 Oslo, Norway E-mail: Copyright Journal compilation © 2009 Scandinavian Society of Clinical Physiology and Nuclear Medicine KEYWORDS endothelial functio...

  19. Finger cold-induced vasodilation : a review

    NARCIS (Netherlands)

    Daanen, H.A.M.

    2003-01-01

    Cold-induced vasodilation (CIVD) in the finger tips generally occurs 5-10 min after the start of local cold exposure of the extremities. This phenomenon is believed to reduce the risk of local cold injuries. However, CIVD is almost absent during hypothermia, when survival of the organism takes prece

  20. Zinc finger structure-function in Ikaros

    Institute of Scientific and Technical Information of China (English)

    Marvin; A; Payne

    2011-01-01

    The zinc finger motif was used as a vehicle for the initial discovery of Ikaros in the context of T-cell differentiation and has been central to all subsequent analyses of Ikaros function.The Ikaros gene is alternately spliced to produce several isoforms that confer diversity of function and consequently have complicated analysis of the function of Ikaros in vivo.Key features of Ikaros in vivo function are associated with six C2H2 zinc fingers;four of which are alternately incorporated in the production of the various Ikaros isoforms.Although no complete structures are available for the Ikaros protein or any of its family members,considerable evidence has accumulated about the structure of zinc fingers and the role that this structure plays in the functions of the Ikaros family of proteins.This review summarizes the structural aspects of Ikaros zinc fingers,individually,and in tandem to provide a structural context for Ikaros function and to provide a structural basis to inform the design of future experiments with Ikaros and its family members.

  1. Finger-jointed beams in bending

    DEFF Research Database (Denmark)

    Andreasen, Lotte; Hoffmeyer, Preben

    1997-01-01

    An investigation of the dynamic and static fatique of finger-jointed beams in bending was carried out. Results were obtained for five different frequencies from static loading to a load cycle period of two minutes. A total of seven series were long-term tested and five series were short-term tested...

  2. Clubbed fingers: the claws we lost?

    NARCIS (Netherlands)

    Brouwers, A.A.M.; Vermeij-Keers, C.; Zoelen, E.J.J. van; Gooren, L.J.G.

    2004-01-01

    Clubbed digits resemble the human embryonic fingers and toes, which took like the digits of a claw. Clubbed digits, thus, may represent the return of the embryonic claw and may even represent the claws man has lost during evolution, if ontogenesis realty recapitulates phylogenesis. We put forward th

  3. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  4. Total hip arthroplasty in a patient with congenital insensitivity to pain: a case report

    Directory of Open Access Journals (Sweden)

    Erdil Mehmet

    2012-07-01

    Full Text Available Abstract Introduction Congenital insensitivity to pain, a rare neurological entity, is characterized by varying degrees of sensory loss and autonomic dysfunction. Orthopedic manifestations of congenital insensitivity to pain include delayed diagnosis of fractures, nonunions, malunions, Charcot arthropathy, acro-osteolysis, avascular necrosis, osteomyelitis, heterotopic ossification and joint dislocations. We here report the case of a patient with congenital insensitivity to pain who had multiple lower extremity fractures at varying intervals, the most recent being a femoral neck fracture managed by total hip replacement. To the best of our knowledge, this is the first report of cementless hip arthroplasty in such a patient. Case presentation A 37-year-old Caucasian woman was admitted to our hospital complaining of painless swellings in her lower limb and limping. She had been diagnosed with multiple lower extremity fractures at different times. On physical examination, we found multiple perioral mucosal ulcers, shortening of her nails and acro-osteolysis, a prematurely aged facial appearance, undersized skeletal structure, Charcot arthropathy of her right ankle, anosmia, insensitivity to temperature differences and evidence of mild intellectual disability. A right subtrochanteric femur fracture was treated with an intramedullary nail. Eighteen months later, she presented with similar symptoms and we diagnosed a right femoral neck fracture. We removed the nail and performed cementless total right hip arthroplasty. Conclusions Congenital insensitivity to pain is a rare condition that is associated with severe orthopedic problems. This case report, which will be of particular interest to orthopedic surgeons, presents several difficulties in the management of patients with congenital insensitivity to pain and notes the importance of close follow-up and early recognition of complications. Cementless total hip arthroplasty may be a good therapeutic

  5. UNCEMENTED PRIMARY TOTAL HIP ARTHROPLASTY FOR OSTEONECROSIS OF HIP WITH SECONDARY OSTEOARTHRITIS IN YOUNG ADULTS

    Directory of Open Access Journals (Sweden)

    Chatla

    2016-03-01

    Full Text Available BACKGROUND Osteonecrosis of the femoral head is a progressive disease that generally affects patients in the third through fifth decade of life, if left untreated. Currently, 18% of all Total Hip Arthroplasty performed in USA are done for Osteonecrosis.(1 The aetiology for the Osteonecrosis varies from idiopathic, alcohol intoxication, steroid abuse or due to childhood hip disorders and hip trauma. We have selected 40 patients suffering from advanced femoral head osteonecrosis with subchondral collapse leading to Osteoarthritis of hip in young adults, treated by uncemented primary total hip replacement. This study is aimed to suggest that uncemented total hip arthroplasty can be applied predictably to this younger, potentially more active patient population. MATERIAL AND METHODS We have done 54 uncemented primary hips in 40 cases with mean follow-up of 5.5 years. The average age of the patient at the time of surgery was 43 years. All the hips are clinically and radiologically examined both pre- and post-operatively. All the cases are operated through postero-lateral approach and have used the fully Hydroxyapatite coated femoral straight stem designed for press fit insertion and hemispherical HA-coated cup inserted with press fit and in few cases we used an HA-coated screw. The patients are under regular follow-up. RESULTS All the patients are reviewed at 6 weeks, 3 months, 6 months and yearly thereafter. The clinical and functional status was recorded using the Harris Hip Score and WOMAC Hip Score. The mean Harris score has improved from an average of 44 points to an average of 93 points postoperatively; 94% showed good-to-excellent results, 2% of cases had shortening, one case developed hip dislocation after two weeks due to unguarded physiotherapy. CONCLUSION The short-term results of cementless total hip arthroplasty in patients with Osteonecrosis of the femoral head were encouraging. We await further follow-up to see if these promising

  6. Torque control of underactuated tendon-driven fingers

    OpenAIRE

    M. E. Abdallah; Wampler, C. W.

    2011-01-01

    Given an underactuated tendon-driven finger, the finger posture is underdetermined and can move freely ("flop") in a region of slack tendons. This work shows that such an underactuated finger can be operated in tendon force control (rather than position control) with effective performance. The force control eliminates the indeterminate slack while commanding a parameterized space of desired torques. The torque will either push the finger to the joint limits or wrap around an external object w...

  7. Ten Trigger Fingers in an Adult Man : A Case Report

    OpenAIRE

    Lee, Young-Keun; Kam, Byung-Sup; Lee, Kwang-Won; Kim, Whoan-Jeang; Choy, Won-Sik

    2007-01-01

    Trigger finger is a common disease particularly in the middle aged women. A very rare case in which an adult man had 10 trigger fingers was experienced. He was treated with local steroid injections in both thumbs, but trigger finger disease has been aggravated in every digit of both hands. We performed an early operative treatment. Three months after the operation, the patient could perform his work without discomfort in his hands and showed normal range of motion in all fingers.

  8. Total Hip Arthroplasty in Mucopolysaccharidosis Type IH

    Directory of Open Access Journals (Sweden)

    S. O'hEireamhoin

    2011-01-01

    Full Text Available Children affected by mucopolysaccharidosis (MPS type IH (Hurler Syndrome, an autosomal recessive metabolic disorder, are known to experience a range of musculoskeletal manifestations including spinal abnormalities, hand abnormalities, generalised joint stiffness, genu valgum, and hip dysplasia and avascular necrosis. Enzyme therapy, in the form of bone marrow transplantation, significantly increases life expectancy but does not prevent the development of the associated musculoskeletal disorders. We present the case of a 23-year-old woman with a diagnosis of Hurler syndrome with a satisfactory result following uncemented total hip arthroplasty.

  9. Navigated minimally invasive unicompartmental knee arthroplasty.

    Science.gov (United States)

    Jenny, Jean-Yves; Müller, Peter E; Weyer, R; John, Michael; Weber, Patrick; Ciobanu, Eugène; Schmitz, Andreas; Bacher, Thomas; Neumann, Wolfram; Jansson, Volkmar

    2006-10-01

    Unicompartmental knee arthroplasty (UKA) is an alternative procedure to high tibial osteotomy. This study assessed the procedure using computer navigation to improve implantation accuracy and presents early radiological results of a group of patients implanted with the univation UKA (B. Braun Aesculap, Tuttlingen, Germany) with navigation instrumentation and a minimally invasive approach. The authors concluded that navigated implantation of a UKA using a nonimage-based system improved radiologic accuracy implantation without significant inconvenience and minimal change in the conventional operating technique. PMID:17407935

  10. Vaginal mass following uncemented total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Young-Soo Shin

    2014-01-01

    Full Text Available A 53-year-old woman developed a vaginal mass following an uncemented total hip arthroplasty. The mass was in direct communication with the hip through an acetabular medial wall defect after loosening of the acetabular component. The mass formation was caused simultaneously by changes secondary to polyethylene wear, a tiny delamination of the porous titanium mesh coating and a broken antirotational tab on the acetabular cup, all of which may have served as sources of metal particles. A careful evaluation of the patient′s history, symptoms, X-ray findings and computed tomography scans should always be performed to ensure accurate diagnosis.

  11. Hip and knee arthroplasty: quo vadis?

    OpenAIRE

    Ho, J; Meis, J. F. G. M.; Nabuurs-Franssen, M.H.; Voss, A.

    2015-01-01

    Despite of the steady decrease of surgical site infection (SSI) over the last two decades, the incidence of SSI after hip and knee arthroplasty has recently surged. This may be explained by technical changes that may result in an increased risk of SSI, such as the broad implementation of fast track programs, and/or early interventions on suspected SSI. By definition, early intervention may lead to a higher SSI score, even in the absence of a true SSI. In any case, the reverse trend of SSI war...

  12. Snapping Pes Syndrome after Unicompartmental Knee Arthroplasty

    Science.gov (United States)

    Taketomi, Shuji; Yamagami, Ryota; Tahara, Keitaro; Tanaka, Sakae

    2016-01-01

    Snapping pes syndrome is defined as a snapping sensation in the medial knee caused by pes anserinus and rarely occurs. Snapping pes syndrome after unicompartmental knee arthroplasty (UKA) has not been reported yet. We experienced two cases with this syndrome after UKA. Conservative treatment was effective in one case, while surgical excision of the gracilis tendon was necessary to relieve painful snapping in the other case. The main cause of the first case might be posteromedial overhang of the tibial tray that reached up to 5 mm. The probable cause of the second case was posteromedial overhang of the mobile bearing.

  13. Error compensation during finger force production after oneand four-finger voluntarily fatiguing exercise

    OpenAIRE

    Kruger, Eric S.; Hoopes, Josh A.; Cordial, Rory J.; Li, Sheng

    2007-01-01

    The effect of muscle fatigue on error compensation strategies during multi-finger ramp force production tasks was investigated. Thirteen young, healthy subjects were instructed to produce a total force with four fingers of the right hand to accurately match a visually displayed template. The template consisted of a 3-s waiting period, a 3-s ramp force production (from 0 to 30% maximal voluntary contraction, MVC), and a 3-s constant force production. A series of twelve ramp trials was performe...

  14. Robot-assisted Guitar Hero for finger rehabilitation after stroke.

    Science.gov (United States)

    Taheri, Hossein; Rowe, Justin B; Gardner, David; Chan, Vicky; Reinkensmeyer, David J; Wolbrecht, Eric T

    2012-01-01

    This paper describes the design and testing of a robotic device for finger therapy after stroke: FINGER (Finger Individuating Grasp Exercise Robot). FINGER makes use of stacked single degree-of-freedom mechanisms to assist subjects in moving individual fingers in a naturalistic grasping pattern through much of their full range of motion. The device has a high bandwidth of control (-3dB at approximately 8 Hz) and is backdriveable. These characteristics make it capable of assisting in grasping tasks that require precise timing. We therefore used FINGER to assist individuals with a stroke (n= 8) and without impairment (n= 4) in playing a game similar to Guitar Hero©. The subjects attempted to move their fingers to target positions at times specified by notes that were graphically streamed to popular music. We show here that by automatically adjusting the robot gains, it is possible to use FINGER to modulate the subject's success rate at the game, across a range of impairment levels. Modulating success rates did not alter the stroke subject's effort, although the unimpaired subjects exerted more force when they were made less successful. We also present a novel measure of finger individuation that can be assessed as individuals play Guitar Hero with FINGER. The results demonstrate the ability of FINGER to provide controlled levels of assistance during an engaging computer game, and to quantify finger individuation after stroke. PMID:23366783

  15. The Replace Operator

    CERN Document Server

    Karttunen, L

    1995-01-01

    This paper introduces to the calculus of regular expressions a replace operator, ->, and defines a set of replacement expressions that concisely encode several alternate variations of the operation. The basic case is unconditional obligatory replacement: UPPER -> LOWER Conditional versions of replacement, such as, UPPER -> LOWER || LEFT _ RIGHT constrain the operation by left and right contexts. UPPER, LOWER, LEFT, and RIGHT may be regular expressions of any complexity. Replace expressions denote regular relations. The replace operator is defined in terms of other regular expression operators using techniques introduced by Ronald M. Kaplan and Martin Kay in "Regular Models of Phonological Rule Systems" (Computational Linguistics 20:3 331-378. 1994).

  16. Diagnosis of infection after total hip arthroplasty

    International Nuclear Information System (INIS)

    Forty-eight total hip arthroplasties for which revision surgery was performed were reviewed to determine the accuracy of laboratory tests, plain radiographs, hip aspiration, and technetium-99m MDP and gallium-67 scans in demonstrating the presence or absence of infection of the prosthesis. Six of the 48 hips were diagnosed as having an infection at the revision surgery. The erythrocyte sedimentation rate and the C-reactive protein levels were significantly higher in the patients with infected prostheses. The difference in the white blood cell count was not significant. There was no significant relationship between the presence of infection and the severity of loosening and instability of the implants diagnosed by plain radiographs. The accuracy of hip aspiration in diagnosing the infection was 83%, with a sensitivity of 40% and a specificity of 92%. The accuracy of technetium-99m MDP bone scan was 79%, with a sensitivity of 83%, and a specificity of 79%. Gallium-67 scan had an accuracy of 96%, a sensitivity of 67%, and a specificity of 100%. The findings in the present study indicated that diagnostic tests consisting of laboratory tests and plain radiography, followed by hip aspiration and sequential use of technetium-99m MDP and gallium-67 scintigraphies, are suitable for differentiation between mechanical loosening and infection of total hip arthroplasty. (author)

  17. Preoperative Planning in Primary Total Knee Arthroplasty.

    Science.gov (United States)

    Tanzer, Michael; Makhdom, Asim M

    2016-04-01

    Preoperative planning is of paramount importance in primary total knee arthroplasty. A thorough preoperative analysis helps the surgeon envision the operation, anticipate any potential issues, and minimize the risk of premature implant failure. Obtaining a thorough history is critical for appropriate patient selection. The physical examination should evaluate the integrity of the soft tissues, the neurovascular status, range of motion, limb deformity, and the status of the collateral ligaments to help determine the soft-tissue balancing and constraint strategy required. Standard radiographs, with a known magnification, should be obtained for preoperative total knee arthroplasty templating. Routine standing AP, lateral, and skyline radiographs of the knee can help the surgeon plan the bone cuts and tibial slope as well as the implant size and position at the time of surgery. In certain circumstances, such as severe coronal deformities, bone deficiencies, and/or extra-articular deformities, additional measures are frequently necessary to successfully reconstruct the knee. Constrained implants, metal augments, and bone graft must be part of the surgeon's armamentarium. PMID:26990712

  18. Robot-assisted total hip arthroplasty.

    Science.gov (United States)

    Banerjee, Samik; Cherian, Jeffery J; Elmallah, Randa K; Pierce, Todd P; Jauregui, Julio J; Mont, Michael A

    2016-01-01

    Precise and accurate biomechanical reconstruction during total hip arthroplasty (THA) is essential for durable long-term survivorship. Accurate fit of cementless hip implants is also crucial to reduce micromotion between the bone-implant interfaces to allow for stable osseointegration. Robotic technology aims to minimize potential human errors and improve implant alignment and fit, and address persisting concerns with modern-day cementless THA. Although robotic THA dates back to the early 1990s, concerns with increased operating times, costs, and complications led to its withdrawal. However, semi-active systems have renewed interest in robot-assisted joint arthroplasty. We reviewed the current technology, its potential benefits, and the reported clinical and radiographic outcomes. Early evidence suggests that robotic use may lead to more accurate reconstruction of radiographic parameters, such as implant positioning, fit, center-of-rotation, and leg-length discrepancy. Further research is needed to determine if these will translate into better outcomes and improved implant longevity to justify increased costs. PMID:26592900

  19. UnconStrained ShoUlder arthroplasty

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Objective: To evaluate the results of 36unconstrained shoulder arthroplasties. Methods: In the series, 24 total and 12 hemiarthroplasties of the shoulders were performed with unconstrained shoulder prostheses in 29 patients who suffered from glenohumeral degenerative arthritis, rheumatoid arthritis, avascular necrosis and proximal fracture of humerus, respectively. Follow-up averaged 6.2years. All patients were evaluated pre- and post-operatively using the rating system of the Society of American Shoulder and Elbow Surgeons which assesses the severity of pain,strength of muscles around shoulder, stability, range of motion and functional activities of daily living. Radiolucent line and migration of prostheses were observed postoperatively on X-rays. Results: Postoperatively, the rate of pain relief was 91.3%, and active range of motion increased by 47° inforward flexion, 43° in abduction , 30° in external rotation,and 4 segments in internal rotation. Preoperatively the average points of 6 functional activities patients could perform was 0.8, and postoperatively 3.1. On postoperative X-ray, proximal migration of the humerus was seen in 8 shoulders, 6 of which had either a torn or absent rotator cuff. Radiolucent lines were seen around 1humeral component and 9 glenoid components. Onehumeral and 2 glenoid components loosened. Conclusions: These results suggest that unconstrained shoulder arthroplasty is a satisfactory and safe technique.

  20. Robot-assisted unicompartmental knee arthroplasty.

    Science.gov (United States)

    Pearle, Andrew D; O'Loughlin, Padhraig F; Kendoff, Daniel O

    2010-02-01

    The outcomes of unicompartmental knee arthroplasties (UKAs) have demonstrated inconsistent long-term survival. We report the first clinical series of UKA using a semiactive robotic system for the implantation of an inlay unicondylar knee arthroplasty. Ten patients were selected for this study. Preoperative mechanical leg alignment values ranged from 0.3 degrees varus to 9.8 degrees varus. A haptic guidance system was used; a detailed description is given in the manuscript. The setup time for the robot was 41 minutes; intraoperative registration process, 7.5 minutes (6-13 minutes); skin incision, 8 cm; robot-assisted burring, 34.8 minutes (18-50 minutes); mean tourniquet time, 87.4 minutes (68-113 minutes); and overall operation time, 132 minutes (118-152 minutes). The planned and intraoperative tibiofemoral angle was within 1 degrees. The postoperative long leg axis radiographs were within 1.6 degrees. Haptic guidance in combination with a navigation module allows for precise planning and execution of both inlay components in UKA. PMID:19056227

  1. Femoral and obturator nerves palsy caused by pelvic cement extrusion after hip arthroplasty.

    Directory of Open Access Journals (Sweden)

    Pawel Zwolak

    2011-05-01

    Full Text Available Cement extrusion into the pelvis with subsequent palsy of the obturator and femoral nerves is a rare entity after hip replacement surgery. Cemented fixation of the acetabular cup has been considered as a safe and reliable standard procedure with very good long term results. We present a case of fifty year old female patient after hip arthroplasty procedure which suffered an obturator and femoral nerve palsy caused by extrusion of bone cement into the pelvis. Postoperative X-rays and CT-scan of the pelvis demonstrated a huge mass consisted of bone cement in close proximity of femoral and obturator nerves. The surgery charts reported shallow and weak bony substance in postero-superior aspect of the acetabulum. This weak bony acetabular substance may have caused extrusion of bone cement during press-fitting of the polyethylene cup into the acetabulum, and the following damage of the both nerves produced by polymerization of bone cement. The bone cement fragment has been surgically removed 3 weeks after arthroplasty. The female patient underwent intensive postoperative physical therapy and electro stimulation which resulted in full recovery of the patient to daily routine and almost normal electromyography results.

  2. A quantitative assessment of facial protection systems in elective hip arthroplasty.

    LENUS (Irish Health Repository)

    Hirpara, Kieran Michael

    2011-06-01

    We aimed to assess the risk to surgeons of blood splatter during total hip arthroplasty. Hoods from personal protection systems used in 34 consecutive total hip replacements were collected and the area of blood splatter was measured and compared to goggles and visors. Thirty one primary THA\\'s (13 cemented, 4 hybrid, 14 uncemented) and 3 revisions (1 hybrid, 2 uncemented) were collected. Splashes were detected on all of the masks with a mean of 034% cover. Splatter was greatest for the operating surgeon, followed by the first assistant, though the difference was not statistically significant. Operating personnel were at greater risk of contamination during uncemented arthroplasty (p < 0.0001; 95% CI). On average 50.60% and 45.40% of blood cover was outside the area protected by goggles and visors respectively. There was a significant difference between the Personal Protection Systems (PPS) and goggles (p = 0.0231; 95% CI) as well as between the PPS and visors (p = 0.0293; 95% CI).

  3. Is cold therapy really efficient after knee arthroplasty?

    Directory of Open Access Journals (Sweden)

    Ersin Kuyucu

    2015-12-01

    Conclusion: After knee arthroplasty, the preoperative and postoperative use of cryotherapy is effective in terms of the pain control and functional knee scores without a significant change in surgical blood loss.

  4. Total knee arthroplasty in patients with a previous patellectomy.

    Science.gov (United States)

    Maslow, Jed; Zuckerman, Joseph D; Immerman, Igor

    2013-01-01

    Post-patellectomy patients represent a specific subgroup of patients that may develop arthritis and persistent knee pain and potentially require treatment with total knee arthroplasty. This article reviews the treatment and functional outcomes following total knee arthroplasty in patients with prior patellectomy. A case report is presented as an example of the clinical management of a post-patellectomy patient with significant knee pain and disability treated with total knee arthroplasty. Emphasis will be placed in decision- making, specifically with the use of a posterior stabilized implant. In addition, postoperative strengthening of the quadriceps is essential to compensate for the lack of the patella and increase the success of total knee arthroplasty in this subgroup of patients. PMID:24151951

  5. Partial knee replacement - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100225.htm Partial knee replacement - series To use the sharing features on ... A.M. Editorial team. Related MedlinePlus Health Topics Knee Replacement A.D.A.M., Inc. is accredited ...

  6. Shoulder Joint Replacement

    Science.gov (United States)

    ... en because of implant loosening, wear, infection, and dislocation. When this occurs, a second joint replacement surgery — called a revision surgery — may be necessary. Is Shoulder Joint Replacement for You? The decision to have ...

  7. Assessment of changes in gait parameters and vertical ground reaction forces after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Bhargava P

    2007-01-01

    Full Text Available The principal objectives of arthroplasty are relief of pain and enhancement of range of motion. Currently, postoperative pain and functional capacity are assessed largely on the basis of subjective evaluation scores. Because of the lack of control inherent in this method it is often difficult to interpret data presented by different observers in the critical evaluation of surgical method, new components and modes of rehabilitation. Gait analysis is a rapid, simple and reliable method to assess functional outcome. This study was undertaken in an effort to evaluate the gait characteristics of patients who underwent arthroplasty, using an Ultraflex gait analyzer. Materials and Methods: The study was based on the assessment of gait and weight-bearing pattern of both hips in patients who underwent total hip replacement and its comparison with an age and sex-matched control group. Twenty subjects of total arthroplasty group having unilateral involvement, operated by posterior approach at our institution with a minimum six-month postoperative period were selected. Control group was age and sex-matched, randomly selected from the general population. Gait analysis was done using Ultraflex gait analyzer. Gait parameters and vertical ground reaction forces assessment was done by measuring the gait cycle properties, step time parameters and VGRF variables. Data of affected limb was compared with unaffected limb as well as control group to assess the weight-bearing pattern. Statistical analysis was done by′t′ test. Results: Frequency is reduced and gait cycle duration increased in total arthroplasty group as compared with control. Step time parameters including Step time, Stance time and Single support time are significantly reduced ( P value < .05 while Double support time and Single swing time are significantly increased ( P value < .05 in the THR group. Forces over each sensor are increased more on the unaffected limb of the THR group as compared to

  8. Association between trochanteric bursitis, osteoarthrosis and total hip arthroplasty,

    OpenAIRE

    Carlos Roberto Schwartsmann; Felipe Loss; Leandro de Freitas Spinelli; Roque Furian; Marcelo Faria Silva; Júlia Mazzuchello Zanatta; Leonardo Carbonera Boschin; Ramiro Zilles Gonçalves; Anthony Kerbes Yépez

    2014-01-01

    OBJECTIVE: this was an epidemiological study on trochanteric bursitis at the time of performing total hip arthroplasty.METHODS: sixty-two sequential patients who underwent total hip arthroplasty due to osteoarthrosis, without any previous history of trochanteric bursitis, were evaluated. The bursas were collected and evaluated histologically.RESULTS: there were 35 female patients (56.5%) and 27 male patients (43.5%), with a mean age of 65 years (±11). Trochanteric bursitis was conformed histo...

  9. TROCHANTERIC ARTHROPLASTY IN THE SEPTIC ARTHRITIC SEOUELA OF THE HIP

    OpenAIRE

    Cakmak, Mehmet; Karamehmetoglu, Mahmut; Taser, Omer; Alturfan, Aziz

    2004-01-01

    7 cases have been treated with trochanteric arthroplasty, in which femoral neads and necks were lost due to the septic arthritic sequela of the hip. These seven cases have been followed for 2,7 years with 1,5 being the youngest 4 the oldest made on the fact that in those cases in which heads and necks are lost in combination, the best solution can be obtained by trochanteric arthroplasty.

  10. Heterotopic Ossification Causing Radiculopathy after Lumbar Total Disc Arthroplasty

    OpenAIRE

    Jackson, Keith L.; Hire, Justin M; Jacobs, Jeremy M.; Key, Charles C.; DeVine, John G.

    2015-01-01

    To date, no reports have presented radiculopathy secondary to heterotopic ossification following lumbar total disc arthroplasty. The authors present a previously unpublished complication of lumbar total disk arthroplasty (TDA) secondary to heterotopic ossification (HO) in the spinal canal, and they propose a modification to the McAfee classification of HO. The patient had undergone an L5/S1 lumbar TDA two years prior due to discogenic back pain. His preoperative back pain was significantly re...

  11. Total Disc Arthroplasty for Treating Lumbar Degenerative Disc Disease

    OpenAIRE

    Mostofi, Keyvan

    2015-01-01

    Study Design Lumber disc arthroplasty is a technological advancement that has occurred in the last decade to treat lumbar degenerative disk diseases. Purpose The aim of this retrospective study was to establish the impact and outcomes of managing patients with lumbar degenerative disk disease who have been treated with lumbar total disc arthroplasty (TDA). Overview of Literature Several studies have shown promising results following this surgery. Methods We reviewed the files of 104 patients ...

  12. Candida glabrata infection following total hip arthroplasty: A case report

    OpenAIRE

    Zhu, Yun; Yue, Chen; Huang, Zeyu; Pei, Fuxing

    2013-01-01

    Candida glabrata infection following total hip arthroplasty is rare and, due to the insufficiency of standardized clinical and evidence-based guidelines, there is no appropriate therapeutic schedule. The present study reports the case of a 44-year-old patient with Candida glabrata infection following a total hip arthroplasty. The patient was successfully treated by administration of intravenous and oral voriconazole without removal of the prosthesis. This case illustrates the significance of ...

  13. Fungal prosthetic joint infection after total knee arthroplasty

    OpenAIRE

    Reddy, Kankanala J; Shah, Jay D; Rohit V Kale; T Jayakrishna Reddy

    2013-01-01

    Fungal prosthetic joint infection after total knee arthroplasty (TKA) is a rare complication. Lacunae exist in the management of this complication. 62 year old lady presented with pain and swelling in left knee and was diagnosed as Candida tropicalis fungal infection after TKA. She underwent debridement, resection arthroplasty and antifungal plus antibiotic loaded cement spacer insertion, antifungal therapy with fluconazole followed by delayed revision TKA and further fluconazole therapy. Tot...

  14. Compartment syndrome and popliteal vascular injury complicating unicompartmental knee arthroplasty

    OpenAIRE

    Kort, Nanne Pieter; Van Raay, Jos J. J. A. M.; van Horn, Jim R.

    2007-01-01

    Popliteal vascular injury and the compartment syndrome of the leg are rare but important complications of knee arthroplasties. Early diagnosis and treatment are of paramount importance in preventing the devastating complications of these conditions. To our knowledge, these complications have not been reported previously after unicompartmental knee arthroplasty in the literature. Low level of suspicion may delay the diagnosis, as popliteal vascular injury and compartment syndrome are not well ...

  15. Popliteal Artery Pseudoaneurysm Following Primary Total Knee Arthroplasty

    OpenAIRE

    Shin, Young-Soo; Hwang, Yeok-Gu; Savale, Abhijit Prakash; Han, Seung-Beom

    2014-01-01

    An early diagnosis of popliteal artery pseudoaneurysm-a sequela of popliteal artery trauma-is difficult owing to its late presentation following total knee arthroplasty. The incidence of a popliteal artery pseudoaneurysm with a hematoma presenting only a peripheral nerve injury after total knee arthroplasty is also uncommon in the absence of common diagnostic features such as a pulsatile swelling with an audible bruit on auscultation. In the present report, we describe popliteal artery pseudo...

  16. The association between metal allergy, total hip arthroplasty, and revision

    OpenAIRE

    Thyssen, Jacob Pontoppidan; Jakobsen, Stig Storgaard; Engkilde, Kåre; Johansen, Jeanne Duus; Søballe, Kjeld; Menné, Torkil

    2009-01-01

    Background and purpose It has been speculated that the prevalence of metal allergy may be higher in patients with implant failure. We compared the prevalence and cause of revisions following total hip arthroplasty (THA) in dermatitis patients suspected to have contact allergy and in patients in general with THA. Furthermore, we compared the prevalence of metal allergy in dermatitis patients with and without THA. Materials and methods The Danish Hip Arthroplasty Registry (DHAR) contained detai...

  17. Systematic review of patellar resurfacing in total knee arthroplasty

    OpenAIRE

    Li, Shuzhen; Chen, Yueping; Su, Wei; Zhao, Jinmin; He, Shunqing; Luo, Xiangping

    2010-01-01

    Controversies existing over resurfacing the patella in total knee arthroplasty remain in the literature. The purpose of this review was to evaluate the effectiveness of resurfacing versus nonresurfacing the patella in total knee arthroplasty. We searched the Cochrane Library, MEDLINE and EMBASE for published randomised clinical trials relevant to patellar resurfacing. The relative risk of reoperation was significantly lower for the patellar resurfacing group than for the nonresurfacing group ...

  18. MOBILE TIBIAL POLYETHYLENE BEARING IN TOTAL KNEE ARTHROPLASTY

    OpenAIRE

    de Araújo Barros Cobra, Hugo Alexandre; da Palma, Idemar Monteiro

    2015-01-01

    Debris of polyethylene tibial bearings have been recognized as a major cause for the onset of the cascade of biological events leading to osteolysis and loosening of prosthetic components after total knee arthroplasty. Since then, research has been focused on alternative bearing surfaces in order to minimize the amount and rate of polyethylene wear off and, in doing so, increasing the survivorship rate for knee arthroplasties. One such option is to have a mobile tibial bearing allowing more c...

  19. Dynamic analysis of C/C composite finger seal

    Institute of Scientific and Technical Information of China (English)

    Chen Guoding; Wang Li’na; Yu Qiangpeng; Su Hua

    2014-01-01

    A seal device as an important component of aeroengines has decisive influence on per-formance, reliability, and working life of aeroengines. With the development of aeroengines, demands on the performance characteristics of seal devices are made strictly. Finger seal as a novel kind of sealing device, recently attracts more and more attentions in academic circles and engineer-ing fields at home and abroad. Research on finger seals has been extensively developed, especially on leakage and wear performances under dynamic conditions. However, it is a pity that the work on finger seals has been limited with a single approach that is improving the performance by structural optimization;in addition, the technology of dynamic analysis on finger seals is weak. Aiming at the problems mentioned above, a distributed mass equivalent dynamic model of finger seals considering the coupling effect of overlaid laminates is established in the present paper, the dynamic perfor-mance of 2.5 dimension C/C composite finger seal is analyzed with the model, and then the effects of fiber bundle density and fiber bundle preparation direction on finger seal’s dynamic performance are discussed, as well as compared with those of Co-based alloy finger seal. The current work is about dynamic analysis of finger seals and application of C/C composite in this paper may have much academic significance and many engineering values for improving research level of finger seal dynamics and exploring feasibility of C/C composite being used for finger seals.

  20. Prediction of DNA-binding specificity in zinc finger proteins

    Indian Academy of Sciences (India)

    Sumedha Roy; Shayoni Dutta; Kanika Khanna; Shruti Singla; Durai Sundar

    2012-07-01

    Zinc finger proteins interact via their individual fingers to three base pair subsites on the target DNA. The four key residue positions −1, 2, 3 and 6 on the alpha-helix of the zinc fingers have hydrogen bond interactions with the DNA. Mutating these key residues enables generation of a plethora of combinatorial possibilities that can bind to any DNA stretch of interest. Exploiting the binding specificity and affinity of the interaction between the zinc fingers and the respective DNA can help to generate engineered zinc fingers for therapeutic purposes involving genome targeting. Exploring the structure–function relationships of the existing zinc finger–DNA complexes can aid in predicting the probable zinc fingers that could bind to any target DNA. Computational tools ease the prediction of such engineered zinc fingers by effectively utilizing information from the available experimental data. A study of literature reveals many approaches for predicting DNA-binding specificity in zinc finger proteins. However, an alternative approach that looks into the physico-chemical properties of these complexes would do away with the difficulties of designing unbiased zinc fingers with the desired affinity and specificity. We present a physico-chemical approach that exploits the relative strengths of hydrogen bonding between the target DNA and all combinatorially possible zinc fingers to select the most optimum zinc finger protein candidate.

  1. Dynamic analysis of C/C composite finger seal

    Directory of Open Access Journals (Sweden)

    Chen Guoding

    2014-06-01

    Full Text Available A seal device as an important component of aeroengines has decisive influence on performance, reliability, and working life of aeroengines. With the development of aeroengines, demands on the performance characteristics of seal devices are made strictly. Finger seal as a novel kind of sealing device, recently attracts more and more attentions in academic circles and engineering fields at home and abroad. Research on finger seals has been extensively developed, especially on leakage and wear performances under dynamic conditions. However, it is a pity that the work on finger seals has been limited with a single approach that is improving the performance by structural optimization; in addition, the technology of dynamic analysis on finger seals is weak. Aiming at the problems mentioned above, a distributed mass equivalent dynamic model of finger seals considering the coupling effect of overlaid laminates is established in the present paper, the dynamic performance of 2.5 dimension C/C composite finger seal is analyzed with the model, and then the effects of fiber bundle density and fiber bundle preparation direction on finger seal’s dynamic performance are discussed, as well as compared with those of Co-based alloy finger seal. The current work is about dynamic analysis of finger seals and application of C/C composite in this paper may have much academic significance and many engineering values for improving research level of finger seal dynamics and exploring feasibility of C/C composite being used for finger seals.

  2. COMPARION OF GAP ARTHROPLASTY AND INTERPOSITIONAL GAP ARTHROPLASTY ON THE TEMPOROMANDIBULAR JOINT ANKYLOSIS

    OpenAIRE

    M. Ramezanian T. Yavary

    2006-01-01

    Temporomandibular joint ankylosis causes limitation in mouth opening and establishes severe deformity and asymmetry in patient’s face, especially in children. Surgery is the only treatment. This study was conducted to compare the effect of two surgical approaches, gap arthropasty and interpositional gap arthroplasty, on rate of maximum interincisal opening in temporomandibular joint ankylosis. We also evaluated the relapse rate of these two surgical approaches. A total of 48 patients were enr...

  3. Nylon-muscle-actuated robotic finger

    Science.gov (United States)

    Wu, Lianjun; Jung de Andrade, Monica; Rome, Richard S.; Haines, Carter; Lima, Marcio D.; Baughman, Ray H.; Tadesse, Yonas

    2015-04-01

    This paper describes the design and experimental analysis of novel artificial muscles, made of twisted and coiled nylon fibers, for powering a biomimetic robotic hand. The design is based on circulating hot and cold water to actuate the artificial muscles and obtain fast finger movements. The actuation system consists of a spring and a coiled muscle within a compliant silicone tube. The silicone tube provides a watertight, expansible compartment within which the coiled muscle contracts when heated and expands when cooled. The fabrication and characterization of the actuating system are discussed in detail. The performance of the coiled muscle fiber in embedded conditions and the related characteristics of the actuated robotic finger are described.

  4. Erosion waves: transverse instabilities and fingering

    OpenAIRE

    Malloggi, F.; Lanuza, J.; Andreotti, B.; Clément, E.

    2005-01-01

    Two laboratory scale experiments of dry and under-water avalanches of non-cohesive granular materials are investigated. We trigger solitary waves and study the conditions under which the front is transversally stable. We show the existence of a linear instability followed by a coarsening dynamics and finally the onset of a fingering pattern. Due to the different operating conditions, both experiments strongly differ by the spatial and time scales involved. Nevertheless, the quantitative agree...

  5. A Color Based Touchless Finger Mouse

    OpenAIRE

    Kah-Meng Kwong; Chin-Poo Lee; Kian-Ming Lim; Siew-Chin Chong; Siti Fatimah Abdul Razak

    2012-01-01

    People work with computers almost anytime, everywhere  in the current trend. However, continuously controlling a computer with mouse for a long time might cause much strains to people’s wrist. This work proposes a touchless finger mouse using webcam. A marker with different colours representing different actions is used. The webcam will capture the information on the marker and trigger the associated actions. This prototype is proven to be able to perform most of the actions a normal mouser c...

  6. Viscous fingering in volatile thin films

    OpenAIRE

    Agam, Oded

    2008-01-01

    A thin water film on a cleaved mica substrate undergoes a first order phase transition between two values of film thickness. By inducing a finite evaporation rate of the water, the interface between the two phases develops a fingering instability similar to that observed in the Saffman-Taylor problem. We draw the connection between the two problems, and construct solutions describing the dynamics of evaporation in this system.

  7. Angiolipoma of index finger: A case report

    Directory of Open Access Journals (Sweden)

    Muzaffer Durmus

    2016-04-01

    Full Text Available Angiolipomas are usually found in the upper extremities, shoulder and back. They are seldom found in the hands, face and lower extremities. They usually occur as painful soft tissue masses or they may compress the neighboring structures (e.g. nerves depending on the size and location. In this report we present an angiolipoma case located in the finger and discuss related recent cases described in the literature. [Hand Microsurg 2016; 5(1.000: 22-25

  8. Angiolipoma of index finger: A case report

    OpenAIRE

    Muzaffer Durmus; Nuri Yigit; Abdul Kerim Yapici

    2016-01-01

    Angiolipomas are usually found in the upper extremities, shoulder and back. They are seldom found in the hands, face and lower extremities. They usually occur as painful soft tissue masses or they may compress the neighboring structures (e.g. nerves) depending on the size and location. In this report we present an angiolipoma case located in the finger and discuss related recent cases described in the literature. [Hand Microsurg 2016; 5(1.000): 22-25

  9. Ferritin, finger clubbing, and lung disease.

    OpenAIRE

    Shneerson, J M; Jones, B M

    1981-01-01

    The serum ferritin concentration has been determined by an immunoradiometric assay in 90 subjects with a variety of pulmonary diseases. No association between ferritin concentrations and finger clubbing has been found in any of the diseases studied. Ferritin levels were significantly raised in the subjects with bronchial carcinoma, but were not useful in monitoring recurrence of the tumour. Pulmonary artery and pulmonary vein ferritin concentrations were similar to systemic venous concentrati...

  10. Fracture of the neck of a femoral component in a total hip arthroplasty: a case report

    OpenAIRE

    Artime, V.; Ramos, J. C.; Fernandez-Medina, J. M.; de Luis, M. C.; Aguilera, L.

    1997-01-01

    Fracture of components of a total hip arthroplasty occur is a recognised complication. We report an unusual case in which the fracture occurred through the neck of a femoral component on a Lord type of total hip arthroplasty.

  11. Pacifier Use, Finger Sucking, and Infant Sleep.

    Science.gov (United States)

    Butler, Rachel; Moore, Melisa; Mindell, Jodi A

    2016-01-01

    Few studies to date have investigated the relationship between pacifier use or finger sucking and infant sleep. One hundred and four mothers of infants (ages 0-11 months) completed the Brief Infant Sleep Questionnaire (BISQ). Infants who engaged in finger sucking had fewer night wakings and longer stretches of nighttime sleep, although less daytime sleep. There were no significant differences in sleep patterns between pacifier users and infants who did not engage in nonnutritive sucking. Furthermore, no significant differences were found across groups for sleep ecology, including parental involvement at bedtime and following night wakings. Finally, infants were consistently able to retrieve their pacifiers independently by 7 months of age, although this did not appear to be associated with sleep outcomes. Results suggest that when parents are deciding whether to give their infant a pacifier, sleep may not be a critical factor. In contrast, parents of finger and thumb suckers should be reassured that this nonnutritive sucking is beneficial to sleep, at least in the first year of life. PMID:26548755

  12. Saffman-Taylor fingers with kinetic undercooling

    CERN Document Server

    Gardiner, Bennett P J; Dallaston, Michael C; Moroney, Timothy J

    2015-01-01

    The mathematical model of a steadily propagating Saffman-Taylor finger in a Hele-Shaw channel has applications to two-dimensional interacting streamer discharges which are aligned in a periodic array. In the streamer context, the relevant regularisation on the interface is not provided by surface tension, but instead has been postulated to involve a mechanism equivalent to kinetic undercooling, which acts to penalise high velocities and prevent blow-up of the unregularised solution. Previous asymptotic results for the Hele-Shaw finger problem with kinetic undercooling suggest that for a given value of the kinetic undercooling parameter, there is a discrete set of possible finger shapes, each analytic at the nose and occupying a different fraction of the channel width. In the limit in which the kinetic undercooling parameter vanishes, the fraction for each family approaches 1/2, suggesting that this 'selection' of 1/2 by kinetic undercooling is qualitatively similar to the well-known analogue with surface tens...

  13. Analysis of Femoral Components of Cemented Total Hip Arthroplasty

    Science.gov (United States)

    Singh, Shantanu; Harsha, A. P.

    2015-10-01

    There have been continuous on-going revisions in design of prosthesis in Total Hip Arthroplasty (THA) to improve the endurance of hip replacement. In the present work, Finite Element Analysis was performed on cemented THA with CoCrMo trapezoidal, CoCrMo circular, Ti6Al4V trapezoidal and Ti6Al4V circular stem. It was observed that cross section and material of femoral stem proved to be critical parameters for stress distribution in femoral components, distribution of interfacial stress and micro movements. In the first part of analysis, designs were investigated for micro movements and stress developed, for different stem materials. Later part of the analysis focused on investigations with respect to different stem cross sections. Femoral stem made of Titanium alloy (Ti6Al4V) resulted in larger debonding of stem at cement-stem interface and increased stress within the cement mantle in contrast to chromium alloy (CoCrMo) stem. Thus, CoCrMo proved to be a better choice for cemented THA. Comparison between CoCrMo femoral stem of trapezium and circular cross section showed that trapezoidal stem experiences lesser sliding and debonding at interfaces than circular cross section stem. Also, trapezium cross section generated lower peak stress in femoral stem and cortical femur. In present study, femur head with diameter of 36 mm was considered for the analysis in order to avoid dislocation of the stem. Also, metallic femur head was coupled with cross linked polyethylene liner as it experiences negligible wear compared to conventional polyethylene liner and unlike metallic liner it is non carcinogenic.

  14. The creation of the artificial RING finger from the cross-brace zinc finger by α-helical region substitution

    International Nuclear Information System (INIS)

    The creation of the artificial RING finger as ubiquitin-ligating enzyme (E3) has been demonstrated. In this study, by the α-helical region substitution between the EL5 RING finger and the Williams-Beuren syndrome transcription factor (WSTF) PHD finger, the artificial E3 (WSTF PHDRING finger) was newly created. The experiments of the chemical modification of residues Cys and the circular dichroism spectra revealed that the WSTF PHDRING finger binds two zinc atoms and adopts the zinc-dependent ordered-structure. In the substrate-independent ubiquitination assay, the WSTF PHDRING finger functions as E3 and was poly- or mono-ubiquitinated. The present strategy is very simple and convenient, and consequently it might be widely applicable to the creation of various artificial E3 RING fingers with the specific ubiquitin-conjugating enzyme (E2)-binding capability.

  15. Small-scale behavior of single gravity-driven fingers in an initially dry fracture

    International Nuclear Information System (INIS)

    Experiments investigating the behavior of individual, gravity-driven fingers in an initially dry, rough-walled analog fracture are presented. Fingers were initiated from constant flow to a point source. Finger structure is described in detail; specific phenomena observed include: desaturation behind the finger-tip, variation in finger path, intermittent flow structures, finger-tip bifurcation, and formation of dendritic sub-fingers. Measurements were made of finger-tip velocity, finger width, and finger-tip length. Non-dimensional forms of the measured variables are analyzed relative to the independent parameters, flow rate and gravitational gradient

  16. Neurologic injuries after primary total ankle arthroplasty: prevalence and effect on outcomes

    OpenAIRE

    Primadi, Andri; Xu, He-Xing; Yoon, Taek-Rim; Ryu, Je-Hwang; Lee, Keun-Bae

    2015-01-01

    Background Neurologic injuries are complications that can arise after total joint arthroplasty. However, no comprehensive study has been conducted on peripheral nerve injuries after total ankle arthroplasty. The purpose of the present study was to identify the prevalence of neurologic injury following primary total ankle arthroplasty, the predisposing factors, and evaluate the effect on clinical outcomes. Methods We retrospectively analyzed 150 consecutive primary total ankle arthroplasty usi...

  17. A mouse model of post-arthroplasty Staphylococcus aureus joint infection to evaluate in vivo the efficacy of antimicrobial implant coatings.

    Directory of Open Access Journals (Sweden)

    Nicholas M Bernthal

    Full Text Available BACKGROUND: Post-arthroplasty infections represent a devastating complication of total joint replacement surgery, resulting in multiple reoperations, prolonged antibiotic use, extended disability and worse clinical outcomes. As the number of arthroplasties in the U.S. will exceed 3.8 million surgeries per year by 2030, the number of post-arthroplasty infections is projected to increase to over 266,000 infections annually. The treatment of these infections will exhaust healthcare resources and dramatically increase medical costs. METHODOLOGY/PRINCIPAL FINDINGS: To evaluate novel preventative therapeutic strategies against post-arthroplasty infections, a mouse model was developed in which a bioluminescent Staphylococcus aureus strain was inoculated into a knee joint containing an orthopaedic implant and advanced in vivo imaging was used to measure the bacterial burden in real-time. Mice inoculated with 5x10(3 and 5x10(4 CFUs developed increased bacterial counts with marked swelling of the affected leg, consistent with an acute joint infection. In contrast, mice inoculated with 5x10(2 CFUs developed a low-grade infection, resembling a more chronic infection. Ex vivo bacterial counts highly correlated with in vivo bioluminescence signals and EGFP-neutrophil fluorescence of LysEGFP mice was used to measure the infection-induced inflammation. Furthermore, biofilm formation on the implants was visualized at 7 and 14 postoperative days by variable-pressure scanning electron microscopy (VP-SEM. Using this model, a minocycline/rifampin-impregnated bioresorbable polymer implant coating was effective in reducing the infection, decreasing inflammation and preventing biofilm formation. CONCLUSIONS/SIGNIFICANCE: Taken together, this mouse model may represent an alternative pre-clinical screening tool to evaluate novel in vivo therapeutic strategies before studies in larger animals and in human subjects. Furthermore, the antibiotic-polymer implant coating

  18. Clinical and Radiographic Mid-Term Outcomes After Total Shoulder Replacement: A Retrospective Study Protocol Including 400 Anatomical and Reverse Prosthetic Implants

    Science.gov (United States)

    Merolla, Giovanni; Tartarone, Antonio; Porcellini, Giuseppe

    2016-01-01

    Objectives: To obtain outcomes data on anatomical and reverse total shoulder arthroplasty by analysis of clinical scores and standard radiographs. Subject selection and enrollment: 400 consecutive series of patients replaced with anatomical and reverse total shoulder arthroplasty (minimum 3 years follow-up). Study Design: retrospective monocenter. Preoperative assessment: Demographics, clinical scores (Constant-Murley) as available, shoulder X-ray (AP, outlet and axillary views) . Last follow-up: Postoperative radiographhs and clinical scores. Adverse events and complications to be reported as occurred since implantation. Statistical analysis: Data collected will be summarized and analyzed for statistical significance. PMID:27326389

  19. Dislocation of primary total hip arthroplasty and the risk of redislocation.

    LENUS (Irish Health Repository)

    Brennan, Stephen A

    2012-09-01

    6554 primary total hip arthroplasties were reviewed. Risk factors for dislocation were analysed to assess which were important in terms of predicting recurrent instability. The patients risk of having a second dislocation was independently associated with the surgical approach adopted (p = 0.03) and the time to first dislocation from the primary hip replacement (p = 0.002). Early dislocators whose surgery was performed through an anterolateral approach had less recurrence than late dislocators through a posterior or transtrochanteric approach. None of the other risk factors including head size (p = 0.59), modularity (p = 0.54), mechanism of dislocation (p = 0.23), leg length discrepancy (p = 0.69) and acetabular inclination (p = 0.31) were influential. The use of an abduction brace was not useful in preventing a further dislocation with 69.2% of those braced re-dislocating compared to 68.5% who were not braced (p = 0.96).

  20. The role of fingers in number processing in young children

    Directory of Open Access Journals (Sweden)

    Anne eLafay

    2013-07-01

    Full Text Available The aim of the present study was to investigate the relationship between finger counting and numerical processing in 4- to 7-year-old children. Children were assessed on a variety of numerical tasks and we examined the correlations between their rates of success and their frequency of finger use in a counting task. We showed that children’s performance on finger pattern comparison and identification tasks did not correlate with the frequency of finger use. However, this last variable correlated with the percentages of correct responses in an enumeration task (i.e., Give-N task, even when the age of children was entered as a covariate in the analysis. Despite this correlation, we showed that some children who never used their fingers in the counting task were able to perform optimally in the enumeration task. Overall, our results support the conclusion that finger counting is useful but not necessary to develop accurate symbolic numerical skills. Moreover, our results suggest that the use of fingers in a counting task is related to the ability of children in a dynamic enumeration task but not to static tasks involving recognition or comparison of finger patterns. Therefore, it could be that the link between fingers and numbers remain circumscribed to counting tasks and do not extent to static finger montring situations.

  1. VISIONS FOR FOOTWEAR TIP SHAPE ACCORDING TO THE CONFIGURATION FINGER

    Directory of Open Access Journals (Sweden)

    MALCOCI Marina

    2015-05-01

    Full Text Available Compatibility between the consumer and the interior leg permanent footwear raises a number of issues. And any new form of footwear is time for a new silhouette last. Fashion is a factor in determining the shape of the last significant role. The most important influence on fashion in footwear that has at one time is found in peak shape. During registered a variety of forms leading to the last, for example, pointed, oval, round, square, asymmetrical, curved, trapezoidal, etc. Each has added a tip top recommended. The paper analyzes the morphofunctional characteristic, namely, finger configuration. The configuration of the fingers is determined from the positions of all the fingers of one another, as are six variants. Analysis of the shape and configuration of the arm fingers allow us to make the following recommendations to consumers: people showing finger configuration as in variant V and VI are advised not to wear pointy shoes because of the limited movement of the foot, which favors the diversion finger I exterior and deformed finger V; persons who fall within I-IV variant can procure pointy shoes; a round-tipped shoes, square, curved or asymmetric may be purchased by any consumer regardless of the configuration of the fingers; shoes with cut edge must be present only in garderopa people in variant I and II; consumers whose configuration is like finger-VI and III variants are awkwardly shaped fingers can buy shoes closed in the previous summer, but of different perforations or overlapping strips.

  2. Postoperative pain treatment after total hip arthroplasty

    DEFF Research Database (Denmark)

    Højer Karlsen, Anders Peder; Geisler, Anja; Petersen, Pernille Lykke;

    2015-01-01

    Treatment of postoperative pain should rely on results from randomized controlled trials and meta-analyses of high scientific quality. The efficacy of a particular intervention may depend on the type of surgical procedure, which supports the reporting of "procedure-specific" interventions. The aim...... of this systematic review was to document the procedure-specific evidence for analgesic interventions after total hip arthroplasty (THA). This PRISMA-compliant and PROSPERO-registered review includes randomized placebo-controlled trials (RCTs) of medication-based analgesic interventions after THA...... reporting of adverse events, considerable differences in supplemental analgesic consumption, and basic analgesic regimens generally characterized trials. Meta-analyses of non-steroidal anti-inflammatory drugs, local infiltration analgesia, intrathecal opioids, and lumbar plexus block provided a 24-hour...

  3. Resection arthroplasty for comminuted olecranon fractures.

    Science.gov (United States)

    Compton, R; Bucknell, A

    1989-02-01

    Five cases of comminuted olecranon fractures treated by resection of the proximal fragments are reviewed. The patients' average age was 56 years and all were radiographically osteopenic. The triceps was advanced and attached to the distal olecranon with the elbow flexed at 90 degrees. A standard postoperative regimen was used with immobilization for three weeks in plaster at 45 to 60 degrees of flexion followed by progression to cautious active range of motion exercises. Follow-up of from 18 to 54 months shows an average active range of motion of 10 degrees flexion to 120 degrees flexion. There were no complaints or clinical evidence of instability and minimal degenerative changes were seen on radiography. We conclude that resection arthroplasty of comminuted olecranon fractures yields excellent clinical and functional results in elderly patients. PMID:2927958

  4. Metaphyseal bone loss in revision knee arthroplasty.

    Science.gov (United States)

    Ponzio, Danielle Y; Austin, Matthew S

    2015-12-01

    The etiology of bone loss encountered during revision total knee arthroplasty (TKA) is often multifactorial and can include stress shielding, osteolysis, osteonecrosis, infection, mechanical loss due to a grossly loose implant, and iatrogenic loss at the time of implant resection. Selection of the reconstructive technique(s) to manage bone deficiency is determined by the location and magnitude of bone loss, ligament integrity, surgeon experience, and patient factors including the potential for additional revision, functional demand, and comorbidities. Smaller, contained defects are reliably managed with bone graft, cement augmented with screw fixation, or modular augments. Large metaphyseal defects require more extensive reconstruction such as impaction bone grafting with or without mesh augmentation, prosthetic augmentation, use of bulk structural allografts, or use of metaphyseal cones or sleeves. While each technique has advantages and disadvantages, the most optimal method for reconstruction of large metaphyseal bone defects during revision TKA is not clearly established. PMID:26362647

  5. Pain Management After Total Joint Arthroplasty.

    Science.gov (United States)

    McDonald, Lisa T; Corbiere, Nicole C; DeLisle, Jay A; Clark, Alexander Martin; Kuxhaus, Laurel

    2016-06-01

    Controlling pain after total joint arthroplasty (TJA) is critical to minimizing complications, decreasing costs, and expediting patients' return to function. We implemented a TJA multimodal pain management protocol at a Level III trauma center in a small, rural community in New York. We retrospectively reviewed 266 patient charts and collected patient demographics, pain management information, and discharge data. Our primary goals were to quantify the total number of narcotic medication doses used and length of hospital stay. The multimodal pain management protocol significantly reduced the number of narcotic doses used (P pain management after TJA can reduce narcotic use and hospital length of stay, thereby also reducing the incidence of side effects from narcotics. PMID:27234795

  6. Fracture Blisters After Primary Total Knee Arthroplasty.

    Science.gov (United States)

    Halawi, Mohamad J

    2015-08-01

    Fracture blisters are tense vesicles that arise on markedly swollen skin overlying traumatized soft tissue. While this relatively uncommon complication has been well described in the trauma literature, this article reports for the first time a case of fracture blisters after primary total knee arthroplasty. The fracture blisters developed within 36 hours of surgery and were associated with profound swelling and erythema. There was no evidence of vascular injury, compartment syndrome, iatrogenic fracture, or deep venous thrombosis. The patient was treated with leg elevation, loosely applied nonadhesive dressings, and a short course of oral antibiotics after skin desquamation. Blood-filled blisters required longer time to reepithelialization than fluid-filled blisters. Knee stiffness developed because of pain and fear of participation with physical therapy, but the patient was able to resume intensive rehabilitation after resolution of the blisters. Patient factors, surgical factors, and review of the literature are discussed. PMID:26251947

  7. Implant survival after total elbow arthroplasty

    DEFF Research Database (Denmark)

    Plaschke, Hans Christian; Thillemann, Theis M; Brorson, Stig;

    2014-01-01

    BACKGROUND: Total elbow arthroplasty (TEA) is an established treatment for late-stage arthritis of the elbow. Indications have expanded to osteoarthritis and nonunion in distal humeral fractures. Information on implant survival and risk factors for revision is still sparse. The aim of this study...... was to evaluate implant survival and risk factors for revision of TEAs inserted in patients in the eastern part of Denmark in the period from 1980 until 2008. MATERIAL AND METHODS: The Danish National Patient Register provided personal identification numbers for patients who underwent TEA procedures...... from 1980 until 2008. On the basis of a review of medical reports and linkage to the National Patient Register, we calculated revision rates and evaluated potential risk factors for revision, including, age, sex, period, indication for TEA, and implant design. RESULTS: We evaluated 324 primary TEA...

  8. Debridement arthroplasty for osteoarthritis of the elbow.

    Science.gov (United States)

    Oka, Y; Ohta, K; Saitoh, I

    1998-06-01

    For treatment of osteoarthritis of the elbow, the authors use debridement arthroplasty with a medial or lateral approach. Thirty-eight elbows in 36 patients treated with this procedure were examined. The age of the patients ranged from 20 to 71 years, with a mean age of 41.7 years. Cubital tunnel syndrome was present in 16 of the 38 (42%) elbows. The operations were performed through a lateral approach in four elbows, a lateral approach with medial skin incision for ulnar nerve neurolysis in 16 elbows, a medial approach in 10 elbows, and a medial plus a lateral approach in eight elbows. The followup ranged from 2 years to 12.1 years, with an average of 5.9 years. Complete pain relief or minimal elbow pain was reported in 95% of patients who had surgical treatment. The average gain in motion was 6 degrees extension and 18 degrees flexion. Results for the various surgical approaches did not show a statistically significant difference. Recurrence of bony spurs and ridges was analyzed additionally in 18 selected patients who could be observed more than 5 years after surgery (range, 5-12 years). Redevelopment of bony spurs on the coronoid process and olecranon tip occurred in all 18 patients, but those changes were graded as mild in 13 (74%) patients and moderate in five (16%) patients and were accompanied by no pain or slight pain. Elbow arthroplasty as used by the authors produces stable and reliable results for relief of pain, gains in range of motion, and the absence of recurrence of significant osteoarthritis. PMID:9646755

  9. Revision of infected knee arthroplasties in Denmark.

    Science.gov (United States)

    Lindberg-Larsen, Martin; Jørgensen, Christoffer C; Bagger, Jens; Schrøder, Henrik M; Kehlet, Henrik

    2016-08-01

    Background and purpose - The surgical treatment of periprosthetic knee infection is generally either a partial revision procedure (open debridement and exchange of the tibial insert) or a 2-stage exchange arthroplasty procedure. We describe the failure rates of these procedures on a nationwide basis. Patients and methods - 105 partial revisions (100 patients) and 215 potential 2-stage revision procedures (205 patients) performed due to infection from July 1, 2011 to June 30, 2013 were identified from the Danish Knee Arthroplasty Register (DKR). Failure was defined as surgically related death ≤ 90 days postoperatively, re-revision due to infection, or not reaching the second stage for a planned 2-stage procedure within a median follow-up period of 3.2 (2.2-4.2) years. Results - The failure rate of the partial revisions was 43%. 71 of the partial revisions (67%) were revisions of a primary prosthesis with a re-revision rate due to infection of 34%, as compared to 55% in revisions of a revision prosthesis (p = 0.05). The failure rate of the 2-stage revisions was 30%. Median time interval between stages was 84 (9-597) days. 117 (54%) of the 2-stage revisions were revisions of a primary prosthesis with a re-revision rate due to infection of 21%, as compared to 29% in revisions of a previously revised prosthesis (p = 0.1). Overall postoperative mortality was 0.6% in high-volume centers (> 30 procedures within 2 years) as opposed to 7% in the remaining centers (p = 0.003). Interpretation - The failure rates of 43% after the partial revision procedures and 30% after the 2-stage revisions in combination with the higher mortality outside high-volume centers call for centralization and reconsideration of surgical strategies. PMID:26900908

  10. Micro-separation in vitro produces clinically relevant wear of ceramic-ceramic total hip replacements

    Energy Technology Data Exchange (ETDEWEB)

    Nevelos, J.; Fisher, J. [Leeds Univ. (United Kingdom). School of Mechanical Engineering; Ingham, E. [Leeds Univ. (United Kingdom). Div. of Microbiology; Doyle, C. [Stryker Howmedica Osteonics, Newbury (United Kingdom); Streicher, R. [Stryker Howmedica Osteonics, Kilchberg (Switzerland); Nevelos, A. [Bradford Royal Infirmary, Bradford (United Kingdom)

    2001-07-01

    Typical clinical wear rates for well-positioned first generation ceramic-ceramic total hip arthroplasties (THAs) were of the order of 1-5 mm{sup 3}/year. This wear took the form of a 'stripe' of worn area on the heads with an Ra of approximately 0.1 {mu}m. As-manufactured unworn areas have an average Ra of 0.005 {mu}m Ra. This wear pattern has not been recorded following standard simulator testing with typical wear rates of less than 0.1 mm{sup 3} per million cycles. Therefore new material combinations for ceramic-ceramic total hip arthroplasty cannot be validated using standard hip simulator testing methods. However, recent fluoroscopy studies have shown that the head and cup of total hip replacements can separate during normal gait. This separation would lead to rim contact upon heel strike as shown in Figure 1. (orig.)

  11. Results of reconstruction for failed total elbow arthroplasty.

    Science.gov (United States)

    Figgie, M P; Inglis, A E; Mow, C S; Wolfe, S W; Sculco, T P; Figgie, H E

    1990-04-01

    Failure of total elbow arthroplasty leads to difficult and complicated surgical reconstruction. This study evaluates the results of reconstruction after implant removal with respect to pain, motion, and functional ability. Between 1978 and 1985, 11 patients required implant removal. Indications for removal were infection for seven, implant fracture for three, and recurrent dislocation for one. The original diagnosis was rheumatoid arthritis in six elbows and traumatic arthritis in five. The average length of the follow-up period was 5.5 years after implant removal (minimum, two years). Treatment consisted of implant removal and soft-tissue arthroplasty combined with external fixation in ten patients, and attempted arthrodesis with external fixation in one. There were four good, one fair, two poor, and four failed results. Satisfactory results were obtained in seven of the eight elbows in which an anatomic arthroplasty was achieved. This consisted of containment of the ulna by the humeral epicondylar remnants. All eight elbows were pain-free with an average arc of motion of 85 degrees (range, 55 degrees to 120 degrees). They had excellent elbow flexion power; however, triceps strength was often compromised. In the three elbows in which anatomic arthroplasty could not be achieved, one was flail, one was later converted to an arthrodesis with a customized plate, and the third required an immediate arthrodesis. All three were rated as failures. Fractures occurred in five of the 11 elbows. One occurred preoperatively, three occurred intraoperatively, and one occurred postoperatively. All healed satisfactorily during the course of immobilization. The importance of an anatomic arthroplasty when removing a total arthroplasty cannot be overemphasized. Retaining the epicondylar segments is important because satisfactory results were obtained in patients in whom entrapment of the olecranon within the epicondylar ridges was obtained. Such patients can achieve a satisfactory

  12. Torque Control of Underactuated Tendon-driven Robotic Fingers

    Science.gov (United States)

    Abdallah, Muhammad E. (Inventor); Ihrke, Chris A. (Inventor); Reiland, Matthew J. (Inventor); Wampler, Charles W. (Inventor); Diftler, Myron A. (Inventor); Platt, Robert (Inventor); Bridgwater, Lyndon (Inventor)

    2013-01-01

    A robotic system includes a robot having a total number of degrees of freedom (DOF) equal to at least n, an underactuated tendon-driven finger driven by n tendons and n DOF, the finger having at least two joints, being characterized by an asymmetrical joint radius in one embodiment. A controller is in communication with the robot, and controls actuation of the tendon-driven finger using force control. Operating the finger with force control on the tendons, rather than position control, eliminates the unconstrained slack-space that would have otherwise existed. The controller may utilize the asymmetrical joint radii to independently command joint torques. A method of controlling the finger includes commanding either independent or parameterized joint torques to the controller to actuate the fingers via force control on the tendons.

  13. [What can we learn in future from the data of the German Arthroplasty Registry (EPRD) in comparison to other registries?].

    Science.gov (United States)

    Jansson, V; Steinbrück, A; Hassenpflug, J

    2016-06-01

    The German Arthroplasty Registry (EPRD) was founded in 2010 and has been in full operation since 2014. Previous attempts at a systematic data collection of elective and non-elective knee and hip replacement in Germany failed mainly because of the long-term lack of funding. The EPRD is an interdisciplinary collaborative partnership between the German Association of Orthopedics and Orthopedic Surgery (DGOOC), all implant manufacturers of the German Medical Technology Association (BVMed), health insurers (AOK and the Association of Additional Healthcare Insurance) and hospitals (German Hospital Federation). As part of this cooperation a worldwide unique implant database has been set up, which includes all relevant components and a detailed description of implant specifications. This implant library enables a detailed evaluation of implant survival, revision rates and possible inferior implant performance of knee and hip replacements in Germany. At the end of 2015 the EPRD encompassed over 200,000 registered operations. Due to the high number of hip and knee arthroplasties in Germany with many different implants from different manufacturers there will be a rapid growth of data that are available for a national and also international comparison of the results. PMID:27160728

  14. Improving esthetics of finger prosthesis by glove silicone

    OpenAIRE

    Laxman Singh Kaira; Esha Dabral

    2014-01-01

    Finger and partial finger amputations are some of the most frequently encountered forms of partial hand loss. A high quality esthetic prosthesis with passive function can be helpful to the patient since loss or congenital absence or malformation have both a social and psychological impact on the patient. Prosthetics is an art and science, which provides lifelike appearance to the lost structures of the patient. This case report presents the fabrication of a silicone finger prosthesis, which h...

  15. Fingering instabilities in Newtonian and non-Newtonian fluids

    Science.gov (United States)

    Kennedy, Kristi E.

    Fingering has been studied in different fluid systems. Viscous fingering, which is driven by a difference in viscosity between fluids, has been studied by both experiments and numerical simulations. We used a single fluid with a temperature-dependent viscosity and studied the instability for a range of inlet pressures and viscosity ratios. The spreading and fingering of a fluid drop subjected to a centrifugal force, known as spin coating, has also been studied for a range of drop volumes and rotation speeds, both for a Newtonian and a non-Newtonian fluid. Experiments on viscous fingering with a single fluid, glycerine, show that an instability occurs at the boundary separating hot and cold fluid. The results indicate that the instability is similar to that which occurs between two miscible fluids. Fingering only occurs for high enough values of the inlet pressure and viscosity ratio. The wavelength of the fingering pattern is found to be proportional to the cell width for the two smallest cell widths used. The fingering patterns seen in the simulations are very similar to the experimental patterns, although there are some quantitative differences. In particular, the wavelength of the instability is seen to depend only weakly on the cell width. The spreading of silicone oil, a Newtonian fluid, during spin coating follows the time dependence predicted theoretically, although with a shift in the scaled time variable. Once the radius of the spreading silicone oil drop becomes large enough, fingers form around the perimeter of the drop for all experimental conditions studied. The number of fingers and the growth rate of the fingers are in agreement with theoretical predictions. Fingers are also observed to form for high enough drop volumes and rotation speeds during the spinning of a non-Newtonian fluid drop, Carbopol, which possesses a yield stress. In this case the fingering is a localized effect, occuring once the stress on the drop exceeds the yield stress, rather

  16. Effective Length Design of Humanoid Robot Fingers Using Biomimetic Optimization

    OpenAIRE

    Byoung-Ho Kim

    2015-01-01

    In this study, we propose an effective design method for the phalangeal parameters and the total size of humanoid robot fingers based on a biomimetic optimization. For the optimization, an interphalangeal joint coordination parameter and the length constraints inherent in human fingers are considered from a biomimetic perspective. A reasonable grasp formulation is also taken into account from the viewpoint of power grasping, where the grasp space of a humanoid robot finger is importantly cons...

  17. Forced ventilation increases variability of isometric finger forces

    OpenAIRE

    Li, Sheng; Yasuda, Nobuo

    2006-01-01

    The study aimed to assess the effects of forced ventilation on variability of the index finger force at the submaximal levels. Fourteen (6 men, 8 women) healthy subjects were instructed to perform self-initiated forced inspiration and forced expiration, the Valsalva maneuver and normal breathing while sustaining 15%, 30%, and 45% of maximal voluntary contraction (MVC) by the index finger. Standard deviation (S.D.) of finger forces increased significantly with the level of force. At each level...

  18. Finteraction : Finger Interaction with Mobile Phone

    OpenAIRE

    Jenabi, Mahsa; Reiterer, Harald

    2008-01-01

    Touch interaction with mobile phones enable users to have a more natural interaction with the device, since touch is a natural way of direct accessing an ob ject of interest. But one disadvantage is occlusion; i.e., the user loses a high percentage of information presented on the small screen of the mobile phone during the interaction using his big finger . On the other hand, interaction enhanced with accelerometers can react according to the device movements, e.g., while the user is tilting...

  19. A Color Based Touchless Finger Mouse

    Directory of Open Access Journals (Sweden)

    Kah-Meng Kwong

    2012-01-01

    Full Text Available People work with computers almost anytime, everywhere  in the current trend. However, continuously controlling a computer with mouse for a long time might cause much strains to people’s wrist. This work proposes a touchless finger mouse using webcam. A marker with different colours representing different actions is used. The webcam will capture the information on the marker and trigger the associated actions. This prototype is proven to be able to perform most of the actions a normal mouser can perform.

  20. Sciatic Nerve Palsy following Total Hip Replacement via Direct Anterior Approach after Recommencement of Warfarin for Prophylaxis in Atrial Fibrillation

    OpenAIRE

    Vipin Asopa; Shafic Al-Nammari; Tony Spriggins; Tony Menz; Adrian Bauze

    2014-01-01

    The occurrence of sciatic nerve palsy following posterior and anterolateral approaches to the hip has been well documented and is about 1-2%. To our knowledge, however, there are no reports of sciatic nerve palsy occurring secondary to the anterior approach to the hip for arthroplasty. We describe a case of sciatic nerve palsy secondary to haematoma formation following total hip replacement through the anterior approach. The recommencement of warfarin for prophylaxis against atrial fibrillati...

  1. Tetanus following replantation of an amputated finger: a case report

    Directory of Open Access Journals (Sweden)

    Hayashida Kenji

    2012-10-01

    Full Text Available Abstract Introduction Tetanus is an infectious disease caused by tetanus toxin produced by Clostridium tetani and induces severe neurological manifestations. We treated a patient who developed tetanus during hospitalization for replantation of an amputated finger. To the best of our knowledge, this is the first published case report of such an entity. Case presentation A 49-year-old Japanese man had an amputation of his right middle finger at the distal interphalangeal joint region in an accident at work. His middle finger was successfully replanted, but his fingertip was partially necrotized because of crushing and so additional reconstruction with a reverse digital arterial flap was performed 15 days after the injury. Tetanus developed 21 days after replantation of the middle finger, but symptoms remitted via rapid diagnosis and treatment. Conclusions In replantation after finger trauma with exposure of nerve and blood vessel bundles, concern over injuring nerves and blood vessels may prevent irrigation and debridement from being performed sufficiently; these treatments may have been insufficiently performed in this patient. It is likely that the replanted middle finger partially adhered, and Clostridium tetani colonized the partially necrotized region. Even when there is only limited soil contamination, administration of tetanus toxoid and anti-tetanus immunoglobulin is necessary when the fingers are injured outdoors and the finger nerves and blood vessels are exposed. The drugs should be administered just after replantation if the finger has been amputated. However, if clinicians pay attention to the possibility of tetanus development, treatment can be rapidly initiated.

  2. Effect of Finger Joint on Flexural Strength of Teak Wood

    Directory of Open Access Journals (Sweden)

    Bharatesh A. Danawade

    2014-01-01

    Full Text Available This paper presents the flexural properties of rectangular Burma teak wood beam without finger joint and with finger joint. Finger joints enable full utilization of wood. Finger jointing technique is also used to eliminate wood defects which weaken the strength of wood. This paper considers finger joint as defined defect and its effect on the flexural strength is determined. Teakwood is hard and heavy, seasons rapidly and has good durability. The specimens were studied under three point bending test. Both edge wise and flat wise tests were carried out. It is observed that Burma teakwood beam without finger joint is stronger than beams with finger joints. Because of finger jointing the flexural strength reduces. It can be concluded that the strength loss can improved upon by selecting suitable geometry of finger joint and a suitable adhesive. It is recognized that further studies are necessary on jointing techniques of wood and type of adhesive so as to equal the flexural strength properties of clear teak wood beams.

  3. The design and development of a finger joint simulator.

    Science.gov (United States)

    Joyce, Thomas J

    2016-05-01

    Artificial finger joints lack the long-term clinical success seen with hip and knee prostheses. In part, this can be explained by the challenges of rheumatoid arthritis, a progressive disease which attacks surrounding tissues as well as the joint itself. Therefore, the natural finger joints' biomechanics are adversely affected, and consequently, this imbalance due to subluxing forces further challenges any prosthesis. Many different designs of finger prosthesis have been offered over a period of greater than 50 years. Most of these designs have failed, and it is likely that many of these failures could have been identified had the prostheses been appropriately tested prior to implantation into patients. While finger joint simulators have been designed, arguably only those from a single centre have been able to reproduce clinical-type failures of the finger prostheses tested in them. This article describes the design and development of a finger simulator at Durham University, UK. It explains and justifies the engineering decisions made and thus the evolution of the finger simulator. In vitro results and their linkage to clinical-type failures are outlined to help to show the effectiveness of the simulator. Failures of finger implants in vivo continue to occur, and the need for appropriate in vitro testing of finger prostheses remains strong. PMID:26833697

  4. Extrinsic versus intrinsic hand muscle dominance in finger flexion.

    Science.gov (United States)

    Al-Sukaini, A; Singh, H P; Dias, J J

    2016-05-01

    This study aims to identify the patterns of dominance of extrinsic or intrinsic muscles in finger flexion during initiation of finger curl and mid-finger flexion. We recorded 82 hands of healthy individuals (18-74 years) while flexing their fingers and tracked the finger joint angles of the little finger using video motion tracking. A total of 57 hands (69.5%) were classified as extrinsic dominant, where the finger flexion was initiated and maintained at proximal interphalangeal and distal interphalangeal joints. A total of 25 (30.5%) were classified as intrinsic dominant, where the finger flexion was initiated and maintained at the metacarpophalangeal joint. The distribution of age, sex, dominance, handedness and body mass index was similar in the two groups. This knowledge may allow clinicians to develop more efficient rehabilitation regimes, since intrinsic dominant individuals would not initiate extrinsic muscle contraction till later in finger flexion, and might therefore be allowed limited early active motion. For extrinsic dominant individuals, by contrast, initial contraction of extrinsic muscles would place increased stress on the tendon repair site if early motion were permitted. PMID:26744509

  5. Infected primary knee arthroplasty: Risk factors for surgical treatment failure

    Directory of Open Access Journals (Sweden)

    Joao Gabriel Duarte Paes Pradella

    2013-09-01

    Full Text Available OBJECTIVE: To present epidemiological data and risk factors associated with surgical out-comes favorable or unfavorable for the treatment of infection in infected total knee arthroplasty. METHODS: We reviewed medical records of 48 patients who underwent treatment of primary total knee arthroplasty for infection between January 1994 and December 2008, in the Orthopedics and Traumatology Department of the Santa Casa de Misericórdia de São Paulo. The variables associated with favorable outcome of surgical treatment (debridement and retention or exchange arthroplasty in two days or unfavorable (arthrodesis or death infection. RESULTS: A total of 39 cases of infection after primary total knee arthroplasty, 22 progressed to 17 for a favorable outcome and unfavorable outcome. Early infections (OR: 14.0, 95% CI 1.5-133.2, p = 0.016 and diabetes (OR: 11.3, 95% CI 1.4-89.3, p = 0.032 were associated with arthrodesis joint and death respectively. CONCLUSION: Patients with early infection had a higher risk of developing surgical procedure with unfavorable outcome (arthrodesis and diabetics had higher odds of death after infection of primary knee arthroplasties.

  6. Hip arthroplasty for failed treatment of proximal femoral fractures.

    Science.gov (United States)

    D'Arrigo, Carmelo; Perugia, Dario; Carcangiu, Alessandro; Monaco, Edoardo; Speranza, Attilio; Ferretti, Andrea

    2010-10-01

    Failed treatment of an intertrochanteric fracture typically leads to profound functional disability and pain. Salvage treatment with hip arthroplasty may be considered. The aim of this study was to evaluate the results and complications of hip arthroplasty performed as a salvage procedure after the failed treatment of an intertrochanteric hip fracture. Twenty-one patients were treated in our hospital with hip arthroplasty for failed treatment of intertrochanteric hip fracture. There were sixteen women and five men with a mean age of 75.8 years (range 61-85 years). Fourteen patients had failure of a previous nail fixation procedure, five had failure of a plate fixation, one of hip screws fixation and one of Ender nail fixation. In 19 out of 21 patients we performed a total hip arthroplasty-14 cases used modular implants with long-stems and five cases used a standard straight stem. In 2 of 21 cases we used a bipolar hemiarthroplasty. A statistically significant improvement was found comparing pre and postoperative conditions (p < 0.05). Our experience confirms that total hip arthroplasty is a satisfactory salvage procedure after failed treatment of an intertrochanteric fracture in elderly patients with few serious orthopaedic complications and acceptable clinical outcomes. PMID:19572131

  7. The Results of ulnohumeral arthroplasty in elbow osteoarthritis

    Directory of Open Access Journals (Sweden)

    M. Dehghani

    2008-01-01

    Full Text Available AbstractBackground and Purpose: Osteoarthritis (OA of elbow is not common but can be disabling, if it is not responding to non-operative methods. Several surgical methods are suggested (joint debridment, ulnohumeral arthroplasty, fusion and total elbow arthroplasty. In this study, we evaluated the result of ulnohumeral arthroplasty in seven patients.Materials and Methods: Seven patients (5 males and 2 females mean age 46 years of age (56-43, during 1378-1385 were operated on with the same approach. Via posterior incision of elbow along with creation of a hole (17mm diameter all of coronoid and olecranon osteophyte were removed.Results: Mean follow-up was 18 months (12-38 months. Patients were evaluated by radiographic, clinical examination and MEPS criteria. Six patients (85% had relief from pain, and obtained good to excellent results, with an increased range of motion at about 53.5 degree. One patient had relative relief of pain and moderate MEPS. After a year, only in one patient osteophyt formation and reduction in range of motion was observed.Conclusion: Due to a good to excellent results of (85%, increased range of motion in the elbow, relief of pain against low cost and short time of hospitalization, ulnohumeral arthroplasty is a suitable method of surgery in osteoarthritis of elbow.Key words: Elbow, Ulnohumeral arthroplasty, OsteoarthritisJ Mazand Univ Med Sci 2008; 18(64: 86-90 (Persian

  8. Fretting and Corrosion in Modular Shoulder Arthroplasty: A Retrieval Analysis

    Science.gov (United States)

    Panzram, Benjamin

    2016-01-01

    Tribocorrosion in taper junctions of retrieved anatomic shoulder arthroplasty implants was evaluated. A comparison of the tribocorrosion between cobalt-chromium and titanium alloy stems was conducted and the observations were correlated with the individual's clinical data. Adverse effects caused by metal debris and subsequent elevated serum metal ion levels are frequently reported in total hip arthroplasty. In total shoulder arthroplasty, to date only a small number of retrieval analyses are available and even fewer address the issue of tribocorrosion at the taper junctions. A total of 36 retrieved hemiarthroplasties and total shoulder arthroplasties were assessed using the modified Goldberg score. The prevalence of fretting and corrosion was confirmed in this cohort. Titanium stems seem to be more susceptible to damage caused by tribocorrosion than cobalt-chromium stems. Furthermore, stemless designs offered less tribocorrosion at the taper junction than stemmed designs. A weak correlation between time to revision and increased levels of tribocorrosion was seen. Whether or not tribocorrosion can lead to adverse clinical reactions and causes failure of shoulder arthroplasties remains to be examined. PMID:27433471

  9. Knee joint replacement

    Science.gov (United States)

    Knee joint replacement is a surgery to replace a knee joint with a man-made joint. The artificial joint is called a prosthesis . ... cartilage and bone are removed from the knee joint. Man-made pieces are then placed in the ...

  10. Replacement nuclear steam generators

    International Nuclear Information System (INIS)

    This paper reviews past and current practices in the replacement of nuclear steam generators. Plants where steam generator replacement has occurred are reviewed to see what changes have been made, and how the evolving technology has significantly reduced outage time and man-rem exposures. Current preferences in design and material are reviewed. 3 refs., 3 tabs., 2 figs

  11. Radiation Source Replacement Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Jeffrey W.; Moran, Traci L.; Bond, Leonard J.

    2010-12-01

    This report summarizes a Radiation Source Replacement Workshop in Houston Texas on October 27-28, 2010, which provided a forum for industry and researchers to exchange information and to discuss the issues relating to replacement of AmBe, and potentially other isotope sources used in well logging.

  12. Asymptomatic deep venous thrombosis in the calf: accuracy and limitations of ultrasonography as a screening test after total knee arthroplasty.

    Science.gov (United States)

    Vanninen, R; Manninen, H; Soimakallio, S; Katila, T; Suomalainen, O

    1993-03-01

    Patients who have recently undergone total knee arthroplasty are at high risk of developing deep venous thrombosis (DVT) in the calf. The clinical diagnosis of DVT is difficult in these patients owing to recent operation. A combination of compression ultrasonography (US) and colour flow imaging was used as a screening method of asymptomatic DVT in 51 patients who had undergone total knee replacement surgery. Both limbs were examined by US from the common femoral vein to the ankle approximately 7 days after operation and the results were compared with bilateral venography. 12 patients (24%) developed infrapopliteal DVT on the operated side, in two cases the thrombosis extended to the lower part of popliteal vein. One patient had bilateral thrombosis. US showed sensitivity of 77%, specificity of 96% and overall accuracy of 93%. US seems to be a useful screening method for DVT after knee replacement operation. PMID:8472111

  13. "Possible TRALI" developed during bilateral total knee arthroplasty replacement -A case report-

    OpenAIRE

    Kim, Youn Jin; Heo, Seok

    2012-01-01

    Transfusion-related acute lung injury (TRALI) is one of the leading causes of transfusion-related morbidity and mortality. However, it is frequently not diagnosed and under-reported, which could result in inappropriate treatment. Diagnostic definition for TRALI consists of hypoxia and bilateral pulmonary edema occurring during or within 6 hours of a transfusion in the absence of cardiac failure or intravascular volume overload. Here, we report a fatal case, which resulted from under-recogniti...

  14. Dorso-palmar triangular finger flap-A new advancement flap for cover of finger amputations-A preliminary report

    Directory of Open Access Journals (Sweden)

    Mishra Satyanarayan

    2001-01-01

    Full Text Available A triangular V-Y type advancement flap on the finger has been designed, which advances skin from over the whole circumference of the finger, which includes both palmar and dorsal skin. The flap is sensate too. It is indicated for finger and thumb amputations proximal to the body of the nail. Six flaps were raised with five successes and one partial necrosis. This is a preliminary report on a new flap.

  15. Teleoperation of Robonaut Using Finger Tracking

    Science.gov (United States)

    Champoux, Rachel G.; Luo, Victor

    2012-01-01

    With the advent of new finger tracking systems, the idea of a more expressive and intuitive user interface is being explored and implemented. One practical application for this new kind of interface is that of teleoperating a robot. For humanoid robots, a finger tracking interface is required due to the level of complexity in a human-like hand, where a joystick isn't accurate. Moreover, for some tasks, using one's own hands allows the user to communicate their intentions more effectively than other input. The purpose of this project was to develop a natural user interface for someone to teleoperate a robot that is elsewhere. Specifically, this was designed to control Robonaut on the international space station to do tasks too dangerous and/or too trivial for human astronauts. This interface was developed by integrating and modifying 3Gear's software, which includes a library of gestures and the ability to track hands. The end result is an interface in which the user can manipulate objects in real time in the user interface. then, the information is relayed to a simulator, the stand in for Robonaut, at a slight delay.

  16. Lipid Gymnastics: Tethers and Fingers in membrane

    Science.gov (United States)

    Tayebi, Lobat; Miller, Gregory; Parikh, Atul

    2009-03-01

    A significant body of evidence now links local mesoscopic structure (e.g., shape and composition) of the cell membrane with its function; the mechanisms by which cellular membranes adopt the specific shapes remain poorly understood. Among all the different structures adopted by cellular membranes, the tubular shape is one of the most surprising one. While their formation is typically attributed to the reorganization of membrane cytoskeleton, many exceptions exist. We report the instantaneous formation of tubular membrane mesophases following the hydration under specific thermal conditions. The shapes emerge in a bimodal way where we have two distinct diameter ranges for tubes, ˜20μm and ˜1μm, namely fat fingers and narrow tethers. We study the roughening of hydrated drops of 3 lipids in 3 different spontaneous curvatures at various temp. and ionic strength to figure out the dominant effect in selection of tethers and fingers. Dynamics of the tubes are of particular interest where we observe four distinct steps of birth, coiling, uncoiling and retraction with different lifetime on different thermal condition. These dynamics appear to reflect interplay between membrane elasticity, surface adhesion, and thermal or hydrodynamic gradient.

  17. Cholinergic vasodilator mechanism in human fingers

    International Nuclear Information System (INIS)

    The effect of a cholinergic agonist and antagonist on finger blood flow (FBF) was studied in 10 normal subjects. Total finger blood flow was measured by venous occlusion, air plethysmography, and capillary blood flow (FCF) by the disappearance rate of a radio-isotope from a fingertip injection. Methacholine in doses of 10-80 μg/min was given by constant infusion via a brachial artery catheter. Average FBF and vascular resistance were not significantly affected. However, the half time (t/sub 1/2/) of the disappearance rate decreased from 50.8 +/- 13.4 to 11.1 +/- 1.5 min; a decrease occurred in all subjects. In seven subjects, atropine (0.2 mg) had no affect alone but inhibited the effect of methacholine on FCF and prevented the redness and sweating of the forearm and hand that occurs with this agent. This study demonstrates a muscarinic cholinergic vasodilator mechanism in the fingertip that uniquely increase capillary blood flow

  18. Cholinergic vasodilator mechanism in human fingers

    Energy Technology Data Exchange (ETDEWEB)

    Coffman, J.D.; Cohen, R.A.

    1987-03-01

    The effect of a cholinergic agonist and antagonist on finger blood flow (FBF) was studied in 10 normal subjects. Total finger blood flow was measured by venous occlusion, air plethysmography, and capillary blood flow (FCF) by the disappearance rate of a radio-isotope from a fingertip injection. Methacholine in doses of 10-80 ..mu..g/min was given by constant infusion via a brachial artery catheter. Average FBF and vascular resistance were not significantly affected. However, the half time (t/sub 1/2/) of the disappearance rate decreased from 50.8 +/- 13.4 to 11.1 +/- 1.5 min; a decrease occurred in all subjects. In seven subjects, atropine (0.2 mg) had no affect alone but inhibited the effect of methacholine on FCF and prevented the redness and sweating of the forearm and hand that occurs with this agent. This study demonstrates a muscarinic cholinergic vasodilator mechanism in the fingertip that uniquely increase capillary blood flow.

  19. Rehabilitation for bilateral amputation of fingers

    Science.gov (United States)

    Stapanian, Martin A.; Stapanian, Adrienne M.P.; Staley, Keith E.

    2010-01-01

    We describe reconstructive surgeries, therapy, prostheses, and adaptations for a patient who experienced bilateral amputation of all five fingers of both hands through the proximal phalanges in January 1992. The patient made considerable progress in the use of his hands in the 10 mo after amputation, including nearly a 120% increase in the active range of flexion of metacarpophalangeal joints. In late 1992 and early 1993, the patient had "on-top plasty" surgeries, in which the index finger remnants were transferred onto the thumb stumps, performed on both hands. The increased web space and functional pinch resulting from these procedures made many tasks much easier. The patient and occupational therapists set challenging goals at all times. Moreover, the patient was actively involved in the design and fabrication of all prostheses and adaptations or he developed them himself. Although he was discharged from occupational therapy in 1997, the patient continues to actively find new solutions for prehension and grip strength 18 yr after amputation.

  20. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

    OpenAIRE

    van Raaij Jos JAM; Bos Nanne; Zijlstra Wierd P

    2008-01-01

    Abstract Background Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: ...

  1. Finger-like voids induced by viscous fingering during phase inversion of alumina/PES/NMP suspensions

    KAUST Repository

    Wang, Bo

    2012-07-01

    The formation mechanism of phase-inversion ceramic hollow fibre membranes has not been well understood. In this paper, we report on the formation of finger-like macrovoids during non-solvent-induced phase inversion of alumina/PES/NMP suspensions. A membrane structure without such finger-like macrovoids was observed when the suspension was slowly immersed into pure ethanol or a mixture of 70. wt% NMP and 30. wt% water, whereas finger-like macrovoids occurred when the suspension was slid into the non-solvents at higher speeds. We found that the formation process of finger-like macrovoids could be fully or partially reversed when nascent membranes were taken out from water shortly after immersion, depending on the duration of the immersion. Splitting of the fingers during the formation of the macrovoids was also observed during the phase inversion of two alumina/PES/NMP suspensions. These experimental observations were not predicted by current theories of finger-like macrovoid formation in polymer membranes, but appear to mimic the well-known viscous fingering phenomenon. We therefore propose that in the phase inversion of ceramic suspensions, the viscous fingering phenomenon is an important mechanism in the formation of finger-like voids. © 2012 Elsevier B.V.

  2. Finger curvature movement recognition interface technique using SEMG signals

    Directory of Open Access Journals (Sweden)

    Y. Itoh

    2007-08-01

    Full Text Available Purpose: Until recently, keyboard has been used as the primary input method for machinery operation system. But in recent years, numerous methods related to direct input interface have been developed. One of them is to measure the surface electric potential that generates on the skin surface during muscle contraction. Based on this fact, hand finger operation can also be recognized with the help of the surface muscle electric potential. The purpose of this study is to identify the hand finger operation using surface electromyogram (SEMG during crookedness state of the finger.Design/methodology/approach: Two electrodes (Ag-AgCl electrode were sticked randomly on the forearm muscles and the intensity of EMG signals at different muscles were measured for each crooked finger. Then depending on the intensity of the obtained electric potentials, a position was located and considered to have participated most actively during the crookedness state of that finger. Thus five locations on the forearm muscles were identified for five different fingers. Moreover, four different types of crookedness states were considered for each finger.Findings: In this experimental study, the electric current that generates on the skin during muscle activity was measured for different hand finger operations. As a result, it is found that there is a specified position related to the maximum intensity of EMG signals for each finger. Practical implications: This paper cleared that the amount of crookedness of each finger can also be recognized with the help of surface EMG. It could be used as a machine interface technology in the field of welfare equipments, robot hand operation, virtual reality, etc.Originality/value: The objective of this research project was to develop the method of recognizing the hand finger operation and their crookedness states from surface electromyogram (SEMG.

  3. Association between trochanteric bursitis, osteoarthrosis and total hip arthroplasty,

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Schwartsmann

    2014-06-01

    Full Text Available OBJECTIVE: this was an epidemiological study on trochanteric bursitis at the time of performing total hip arthroplasty.METHODS: sixty-two sequential patients who underwent total hip arthroplasty due to osteoarthrosis, without any previous history of trochanteric bursitis, were evaluated. The bursas were collected and evaluated histologically.RESULTS: there were 35 female patients (56.5% and 27 male patients (43.5%, with a mean age of 65 years (±11. Trochanteric bursitis was conformed histologically in nine patients (14.5%, of whom six were female (66.7% and three were male (33.3%.CONCLUSIONS: 14.5% of the bursas analyzed presented inflammation at the time that the primary total hip arthroplasty due to osteoarthrosis was performed, and the majority of the cases of bursitis were detected in female patients.

  4. TMJ ANKYLOSIS: MANAGEMENT WITH RECONSTRUCTION AND INTERPOSITIONAL ARTHROPLASTY.

    Science.gov (United States)

    Madhumati, Singh; Shruthi, R; Mitul, Sojitra; Karan, Abhishek; Aziz, Abdul

    2015-01-01

    Temporomandibular joint (TMJ) ankylosis is a very desolating structural condition that involves fusion of the mandibular condyle to the base of the skull. It causes difficulty in mastication and breathing. Trauma and Infections are usually responsible. If trauma occurs in young age, it leads to disturbance in growth & facial asymmetry. Treatment of temporomandibular joint (TMJ) ankylosis usually requires adequate excision of the involved ankylotic block (arthroplasty) or interpositional arthroplasty using autogenous or alloplastic materials. Early mobilization, physiotherapy & strict follow up are essential to prevent postop adhesions. In our cases fascia lata was used as an interpositional grafting material. One case was treated by gap arthroplasty, second case by costochondral graft & third case was managed with titanium condylar prosthesis. PMID:27487617

  5. The association between metal allergy, total knee arthroplasty, and revision

    DEFF Research Database (Denmark)

    Münch, Henrik J; Jakobsen, Stig Storgaard; Olesen, Jens T; Menné, Torkil; Søballe, Kjeld; Johansen, Jeanne D; Thyssen, Jacob P

    2015-01-01

    Background and purpose - It is unclear whether delayed-type hypersensitivity reactions against implanted metals play a role in the etiopathogenesis of malfunctioning total knee arthroplasties. We therefore evaluated the association between metal allergy, defined as a positive patch test reaction to...... common metal allergens, and revision surgery in patients who underwent knee arthroplasty. Patients and methods - The nationwide Danish Knee Arthroplasty Register, including all knee-implanted patients and revisions in Denmark after 1997 (n = 46,407), was crosslinked with a contact allergy patch test...... database from the greater Copenhagen area (n = 27,020). Results - 327 patients were registered in both databases. The prevalence of contact allergy to nickel, chromium, and cobalt was comparable in patients with and without revision surgery. However, in patients with 2 or more episodes of revision surgery...

  6. Computer-Navigated Total Knee Arthroplasty Utilization.

    Science.gov (United States)

    Bala, Abiram; Penrose, Colin Thomas; Seyler, Thorsten Markus; Mather, Richard Chad; Wellman, Samuel Secord; Bolognesi, Michael Paul

    2016-07-01

    Computer-navigated total knee arthroplasty (CN-TKA) has been used to improve component alignment, though the evidence is currently mixed on whether there are clinically significant differences in long-term outcomes. Given the established increased costs and operative time, we hypothesized that the utilization rate of CN-TKA would be decreasing relative to standard TKA in the Medicare population given the current health care economic environment. We queried 1,914,514 primary TKAs performed in the entire Medicare database from 2005 to 2012. Current Procedural Terminology (CPT) and International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes were used to identify and separate CN-TKAs. Utilization of TKA was compared by year, gender, and region. Average change in cases per year and compound annual growth rate (CAGR) were used to evaluate trends in utilization of the procedure. We identified 30,773 CN-TKAs performed over this time period. There was an increase in utilization of CN-TKA per year from 984 to 5,352 (average = 572/year, R (2) = 0.85, CAGR = 23.58%) from 2005 to 2012. In contrast, there was a slight decrease in overall TKA utilization from 264,345 to 230,654 (average = 4297/year, R (2) = 0.74, CAGR = - 1.69%). When comparing proportion of CN-TKA to all TKAs, there was an increase from 0.37 to 2.32% (average 0.26%/year, R (2) = 0.88, CAGR = 25.70%). CN-TKA growth in males and females was comparable at 24.42 and 23.11%, respectively. The South region had the highest growth rate at 28.76%, whereas the Midwest had the lowest growth rate at 15.51%. The Midwest was the only region that peaked (2008) with a slow decline in utilization until 2012. Despite increased costs with unclear clinical benefit, CN-TKA is increasing in utilization among Medicare patients. Reasons could include patient preference, advertising, proper of coding the procedure, and increased publicly available information about

  7. Shoulder arthroplasty. Part 2: Normal and abnormal radiographic findings

    International Nuclear Information System (INIS)

    Frequently, the decision made by general practitioners or musculoskeletal triage assessment services to refer patients for specialist review is initiated by a radiological report. Following shoulder arthroplasty it is important to ensure that any patient with asymptomatic evidence of a failing prosthesis is referred for review so that revision surgery can be contemplated and planned before the situation becomes unsalvageable. The first paper in this series described the various types of shoulder arthroplasty and indications for each. This follow-up paper will concentrate on their modes of failure and the associated radiographic features, and is aimed at radiology trainees and non-musculoskeletal specialist radiologists.

  8. The triceps preserving approach to total elbow arthroplasty.

    Science.gov (United States)

    Pierce, T D; Herndon, J H

    1998-09-01

    Elbow arthroplasty most commonly is performed through a posterior approach by detaching or reflecting the triceps off the olecranon. Surgical approaches to the elbow joint that dissociate the triceps from the olecranon have distinct disadvantages. Triceps avulsion, triceps weakness, and wound healing problems have been reported. Such complications necessitate more surgery and predispose the joint to an infection. To avoid these complications a modified posterior approach to the elbow joint that preserves the triceps muscle insertion on the olecranon was used in 10 consecutive elbow arthroplasties. This method provides adequate exposure, allows early rehabilitation, and avoids triceps weakness. PMID:9755773

  9. Mid-Term Results of Oxford Medial Unicompartmental Knee Arthroplasty

    OpenAIRE

    Choy, Won-Sik; Kim, Kap Jung; Lee, Sang Ki; Yang, Dae Suk; Lee, Neung Ki

    2011-01-01

    Background This study examined the clinical and radiologic mid-term results of patients treated by Oxford minimally invasive unicompartmental knee arthroplasty. Methods One hundred and eighty-eight knees of unicompartmental knee arthroplasties with Oxford Uni® in 166 patients (16 males and 150 females), which were performed between 2002 and 2005, were reviewed. The mean age was 65.3 years (range, 44 to 82 years) and the mean follow-up period was 79.8 months (range, 56 to 103 months). The preo...

  10. Reverse shoulder arthroplasty: radiological and clinical short–term results

    OpenAIRE

    Atalar, Ata Can; Salduz, Ahmet; Cil, Hilal; Sungur, Mustafa; Celik, Derya; Demirhan, Mehmet

    2014-01-01

    Objective: The aim of this study was to examine the radiological and clinical short term results of the patients who underwent reverse shoulder arthroplasty for rotator cuff arthropathy. Methods: The study included 14 (2 male, 12 female) patients who underwent reverse shoulder arthroplasty for rotator cuff arthropathy between 2009 and 2010. The mean age of the patients was 74 (57–80) years and the mean follow–up period was 32 (21–40) months. Radiological methods as well as the range of mot...

  11. Shoulder arthroplasty. Part 2: Normal and abnormal radiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Sheridan, B.D., E-mail: bdsheridan@hotmail.com [Department of Orthopaedic Surgery, Bristol Royal Infirmary, Bristol (United Kingdom); Ahearn, N.; Tasker, A.; Wakeley, C.; Sarangi, P. [Department of Orthopaedic Surgery, Bristol Royal Infirmary, Bristol (United Kingdom)

    2012-07-15

    Frequently, the decision made by general practitioners or musculoskeletal triage assessment services to refer patients for specialist review is initiated by a radiological report. Following shoulder arthroplasty it is important to ensure that any patient with asymptomatic evidence of a failing prosthesis is referred for review so that revision surgery can be contemplated and planned before the situation becomes unsalvageable. The first paper in this series described the various types of shoulder arthroplasty and indications for each. This follow-up paper will concentrate on their modes of failure and the associated radiographic features, and is aimed at radiology trainees and non-musculoskeletal specialist radiologists.

  12. Wear particles and osteolysis in patients with total wrist arthroplasty

    DEFF Research Database (Denmark)

    Boeckstyns, Michel E H; Toxværd, Anders; Bansal, Manjula; Vadstrup, Lars Soelberg

    2014-01-01

    tissue, the level of chrome and cobalt ions in the blood, and the possible role of infectious or rheumatoid activity in the development of PPO. METHODS: Biopsies were taken from the implant-bone interphase in 13 consecutive patients with total wrist arthroplasty and with at least 3 years' follow...... of the radiolucent zone. The blood levels of chrome and cobalt ions were normal. There was no evidence of infectious or rheumatoid activity. CONCLUSIONS: Polyethylene wear has been accepted as a major cause of osteolysis in total hip arthroplasty, and metallic debris has also been cited to be an...

  13. The constraints on day-case total knee arthroplasty

    DEFF Research Database (Denmark)

    Thienpont, E; Lavand'homme, P; Kehlet, H

    2015-01-01

    Total knee arthroplasty (TKA) is a major orthopaedic intervention. The length of a patient's stay has been progressively reduced with the introduction of enhanced recovery protocols: day-case surgery has become the ultimate challenge. This narrative review shows the potential limitations of day...... in a limited group of patients. The younger, male patient without comorbidities and with an excellent social network around him might be a candidate. Demographic changes, effective recovery programmes and less invasive surgical techniques such as unicondylar knee arthroplasty, may increase the size...

  14. Detection of finger gesture using singular spectrum transformation

    International Nuclear Information System (INIS)

    The purpose of this study is to detect finger movement using a singular spectrum transformation method. Human gesture recognition is essential for realizing natural user interfaces. However, constructing a robust, easily installable interface is extremely difficult. Our proposed method uses singular spectrum transformation to classify finger movements. This method robustly classifies gestures and behavior

  15. Handedness and index finger movements performed on a small touchscreen.

    Science.gov (United States)

    Aoki, Tomoko; Rivlis, Gil; Schieber, Marc H

    2016-02-01

    Many studies of right/left differences in motor performance related to handedness have employed tasks that use arm movements or combined arm and hand movements rather than movements of the fingers per se, the well-known exception being rhythmic finger tapping. We therefore explored four simple tasks performed on a small touchscreen with relatively isolated movements of the index finger. Each task revealed a different right/left performance asymmetry. In a step-tracking Target Task, left-handed subjects showed greater accuracy with the index finger of the dominant left hand than with the nondominant right hand. In a Center-Out Task, right-handed subjects produced trajectories with the nondominant left hand that had greater curvature than those produced with the dominant right hand. In a continuous Circle Tracking Task, slips of the nondominant left index finger showed higher jerk than slips of the dominant right index finger. And in a continuous Complex Tracking Task, the nondominant left index finger showed shorter time lags in tracking the relatively unpredictable target than the dominant right index finger. Our findings are broadly consistent with previous studies indicating left hemisphere specialization for dynamic control and predictable situations vs. right hemisphere specialization for impedance control and unpredictable situations, the specialized contributions of the two hemispheres being combined to different degrees in the right vs. left hands of right-handed vs. left-handed individuals. PMID:26683065

  16. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint polymer constrained prosthesis. 888... constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended... generic type of device includes prostheses that consist of a single flexible across-the-joint...

  17. Melorheostosis of the index finger: a case report

    OpenAIRE

    Quarles, Ellen K.; Richardson, Michael L.

    2015-01-01

    We describe a case of melorheostosis involving multiple bones of the left index finger. This patient presented with a many-year history of a finger mass, and demonstrated the typical radiographic findings of melorheostosis on radiographs and computed tomography (CT) of the hand. Following excisional biopsy and bone grafting, this patient is doing well and undergoing physical therapy.

  18. Emerging technologies in arthroplasty: additive manufacturing.

    Science.gov (United States)

    Banerjee, Samik; Kulesha, Gene; Kester, Mark; Mont, Michael A

    2014-06-01

    Additive manufacturing is an industrial technology whereby three-dimensional visual computer models are fabricated into physical components by selectively curing, depositing, or consolidating various materials in consecutive layers. Although initially developed for production of simulated models, the technology has undergone vast improvements and is currently increasingly being used for the production of end-use components in various aerospace, automotive, and biomedical specialties. The ability of this technology to be used for the manufacture of solid-mesh-foam monolithic and coated components of complex geometries previously considered unmanufacturable has attracted the attention of implant manufacturers, bioengineers, and orthopedic surgeons. Currently, there is a paucity of reports describing this fabrication method in the orthopedic literature. Therefore, we aimed to briefly describe this technology, some of the applications in other orthopedic subspecialties, its present use in hip and knee arthroplasty, and concerns with the present form of the technology. As there are few reports of clinical trials presently available, the true benefits of this technology can only be realized when studies evaluating the clinical and radiographic outcomes of cementless implants manufactured with additive manufacturing report durable fixation, less stress shielding, and better implant survivorship. Nevertheless, the authors believe that this technology holds great promise and may potentially change the conventional methods of casting, machining, and tooling for implant manufacturing in the future. PMID:24764230

  19. Patient-reported outcome measures in arthroplasty registries Report of the Patient-Reported Outcome Measures Working Group of the International Society of Arthroplasty Registries Part II. Recommendations for selection, administration, and analysis.

    Science.gov (United States)

    Rolfson, Ola; Bohm, Eric; Franklin, Patricia; Lyman, Stephen; Denissen, Geke; Dawson, Jill; Dunn, Jennifer; Eresian Chenok, Kate; Dunbar, Michael; Overgaard, Søren; Garellick, Göran; Lübbeke, Anne

    2016-07-01

    - The International Society of Arthroplasty Registries (ISAR) Patient-Reported Outcome Measures (PROMs) Working Group have evaluated and recommended best practices in the selection, administration, and interpretation of PROMs for hip and knee arthroplasty registries. The 2 generic PROMs in common use are the Short Form health surveys (SF-36 or SF-12) and EuroQol 5-dimension (EQ-5D). The Working Group recommends that registries should choose specific PROMs that have been appropriately developed with good measurement properties for arthroplasty patients. The Working Group recommend the use of a 1-item pain question ("During the past 4 weeks, how would you describe the pain you usually have in your [right/left] [hip/knee]?"; response: none, very mild, mild, moderate, or severe) and a single-item satisfaction outcome ("How satisfied are you with your [right/left] [hip/knee] replacement?"; response: very unsatisfied, dissatisfied, neutral, satisfied, or very satisfied). Survey logistics include patient instructions, paper- and electronic-based data collection, reminders for follow-up, centralized as opposed to hospital-based follow-up, sample size, patient- or joint-specific evaluation, collection intervals, frequency of response, missing values, and factors in establishing a PROMs registry program. The Working Group recommends including age, sex, diagnosis at joint, general health status preoperatively, and joint pain and function score in case-mix adjustment models. Interpretation and statistical analysis should consider the absolute level of pain, function, and general health status as well as improvement, missing data, approaches to analysis and case-mix adjustment, minimal clinically important difference, and minimal detectable change. The Working Group recommends data collection immediately before and 1 year after surgery, a threshold of 60% for acceptable frequency of response, documentation of non-responders, and documentation of incomplete or missing data. PMID

  20. Total Knee Replacement

    Science.gov (United States)

    ... following total knee replacement include unlimited walking, swimming, golf, driving, light hiking, biking, ballroom dancing, and other ... to the final success of your surgery. To learn more about the full value of total knee ...

  1. Hormone Replacement Therapy

    Science.gov (United States)

    ... before and during menopause, the levels of female hormones can go up and down. This can cause ... hot flashes and vaginal dryness. Some women take hormone replacement therapy (HRT), also called menopausal hormone therapy, ...

  2. Knee joint replacement - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100088.htm Knee joint replacement - series To use the sharing features ... 4 out of 4 Normal anatomy Overview The knee is a complex joint. It contains the distal ...

  3. Effect of bending pattern on finger joint bending strength

    Directory of Open Access Journals (Sweden)

    Džinčić Igor

    2012-01-01

    Full Text Available Limited information is available on end gluing hardwoods in contrast to softwoods, which have been extensively investigated. The objective of this study was to examine the influence of bending patern on bending strength of finger jointed beech wood. In structural uses finger jointing is finally the major method to end joint timber for the production of glue-laminated elements. There are no bending strength experimental results for finger-jointed hardwoods for investigations conducted in Serbia. Two finger jointed profiles were studied in accordance with DIN68140. The finger joints were made by side and by face of beam. Length jointed samples were loaded at the side and in the face. The obtained results led to the conclusion that the direction of load, gluing surface and the position of joint influence on the strength of continued longitudinal beams.

  4. A new algorithmic approach for fingers detection and identification

    Science.gov (United States)

    Mubashar Khan, Arslan; Umar, Waqas; Choudhary, Taimoor; Hussain, Fawad; Haroon Yousaf, Muhammad

    2013-03-01

    Gesture recognition is concerned with the goal of interpreting human gestures through mathematical algorithms. Gestures can originate from any bodily motion or state but commonly originate from the face or hand. Hand gesture detection in a real time environment, where the time and memory are important issues, is a critical operation. Hand gesture recognition largely depends on the accurate detection of the fingers. This paper presents a new algorithmic approach to detect and identify fingers of human hand. The proposed algorithm does not depend upon the prior knowledge of the scene. It detects the active fingers and Metacarpophalangeal (MCP) of the inactive fingers from an already detected hand. Dynamic thresholding technique and connected component labeling scheme are employed for background elimination and hand detection respectively. Algorithm proposed a new approach for finger identification in real time environment keeping the memory and time constraint as low as possible.

  5. Geometric approach to viscous fingering on a cone

    International Nuclear Information System (INIS)

    We study fluid flow and the formation of viscous fingering patterns on a two-dimensional conical background space, defined as the conical Hele-Shaw cell. We approach the problem geometrically and study how the nontrivial topological structure of the conical cell affects the evolution of the interface separating two viscous fluids. We perform a perturbative weakly nonlinear analysis of the problem and derive a mode-coupling differential equation which describes fluid-fluid interface behaviour. Our nonlinear study predicts the formation of fingering structures in which fingers of different lengths compete and split at their tips. The shape of the emerging patterns show a significant sensitivity to variations in the cell's topological features, which can be monitored by changing the cone opening angle. We find that for increasingly larger values of the opening angle, finger competition is inhibited while finger tip-splitting is enhanced

  6. The replacement research reactor

    International Nuclear Information System (INIS)

    As a consequences of the government decision in September 1997. ANSTO established a replacement research reactor project to manage the procurement of the replacement reactor through the necessary approval, tendering and contract management stages This paper provides an update of the status of the project including the completion of the Environmental Impact Statement. Prequalification and Public Works Committee processes. The aims of the project, management organisation, reactor type and expected capabilities are also described

  7. Transcatheter Pulmonary Valve Replacement

    OpenAIRE

    Ghawi, Hani; Kenny, Damien; Hijazi, Ziyad M.

    2012-01-01

    Transcatheter pulmonary valve replacement (tPVR) has evolved into a viable alternative to surgical conduit or bioprosthetic valve replacement. This procedure has paved the way for a more advanced approach to congenital and structural interventional cardiology. Although many successes have been noted, there are still a number of challenges with this procedure, including large delivery systems, the need for a conduit or a bioprosthetic valve as a landing zone for the valve, optimal timing of th...

  8. Total elbow arthroplasty in patients who have juvenile rheumatoid arthritis.

    Science.gov (United States)

    Connor, P M; Morrey, B F

    1998-05-01

    Patients who have juvenile rheumatoid arthritis often are seen at a very young age because of severe stiffness and pain in several joints. While total elbow replacement may be indicated in these patients, this procedure is difficult to perform because of contracture of the soft tissues and the extremely small bones and intramedullary cavities in these patients. As there is little information in the literature regarding this procedure, we attempted to learn about the long-term results by evaluating nineteen patients (twenty-four elbows) with juvenile rheumatoid arthritis who had been managed with total elbow arthroplasty. At an average of 7.4 years (range, two to fourteen years) after the operation, there was an improvement in the average Mayo elbow performance score from 31 points (range, 5 to 55 points) preoperatively to 90 points (range, 55 to 100 points). Twenty-two (96 per cent) of the twenty-three elbows available at the most recent follow-up evaluation caused little or no pain, but the improvement in the range of motion was not as reliable. The average arc of flexion improved from only 63 degrees preoperatively to 90 degrees postoperatively; the average postoperative arc of flexion began at 35 degrees, with additional flexion to 125 degrees. Examination of the four elbows that had been ankylosed before the procedure revealed an average arc of 73 degrees after the operation, and evaluation of the twenty ipsilateral wrists that were not limited by disease revealed that pronation and supination had been maintained. The average functional score improved from 9 points (range, 0 to 25 points) preoperatively to 23 points (range, 15 to 25 points) postoperatively (p olecranon, subluxation of the prosthesis, stiffness of the elbow, and problems with wound-healing, led to an additional operative procedure but did not adversely affect the long-term outcome after appropriate diagnosis and treatment. Late complications (aseptic loosening, instability, and worn bushings

  9. Surface Tension and Fingering of Miscible Interfaces

    Science.gov (United States)

    Abib, Mohammed; Liu, Jian-Bang; Ronney, Paul D.

    1999-01-01

    Experiments on miscible, buoyantly unstable reaction-diffusion fronts and non-reacting displacement fronts in Hele-Shaw cells show a fingering-type instability whose wavelengths (lambda*) are consistent with an interfacial tension (sigma) at the front caused by the change in chemical composition, even though the solutions are miscible in all proportions. In conjunction with the Saffman-Taylor model, the relation sigma = K/tau, where tau is the interface thickness and K approximately equal 4 +/- 2 x 10(exp -6) dyne, enables prediction of our measured values of lambda* as well as results from prior experiments on miscible interfaces. These results indicate that even for miscible fluids, surface tension is generally a more significant factor than diffusion in interfacial stability and flow characteristics.

  10. Pain catastrophizing as a risk factor for chronic pain after total knee arthroplasty: a systematic review

    Directory of Open Access Journals (Sweden)

    Burns LC

    2015-01-01

    predictor of chronic pain persisting ≥3 months following TKA in five of the studies assessed. Limitations of studies included lack of large-scale data, absence of standardized pain measurements, inadequate multivariate adjustment, such as failure to control for analgesic use and other relevant covariates, and failure to report non-significant parameter estimates. Conclusion: This study provides moderate-level evidence for pain catastrophizing as an independent predictor of chronic pain post-TKA. Directions for future research include larger, well-controlled studies with standard pain outcomes, identification of clinically-relevant catastrophizing cut-offs that predict pain outcomes, investigation of other psychosocial risk factors, and assessment of interventions aimed to reduce pain catastrophizing on chronic pain outcomes following TKA surgery. Keywords: pain catastrophizing, total knee arthroplasty, total knee replacement, knee arthroplasty, risk factors, chronic pain

  11. Perioperative safety of two-team simultaneous bilateral total knee arthroplasty in the obese patient

    Directory of Open Access Journals (Sweden)

    Gaines Steven T

    2010-06-01

    Full Text Available Abstract Background Although the rates of perioperative morbidity and mortality with simultaneous bilateral total knee arthroplasty remain a concern, multiple studies have shown the procedure to be safe in selected patient populations. Evidence also remains mixed regarding the outcomes of total knee arthroplasty in obese patients. The purpose of this paper is to compare the rates of perioperative morbidity and mortality in consecutive obese patients undergoing two-team simultaneous bilateral total knee arthroplasty and unilateral total knee arthroplasty. Methods The records on all two-team simultaneous total knee arthroplasties and unilateral total knee arthroplasties from October 1997 to December 2007 were reviewed. A total of 151 patients with a body mass index (BMI >30 undergoing two-team simultaneous total knee arthroplasty and 148 patients with a BMI >30 undergoing unilateral total knee arthroplasty were retrospectively reviewed and analyzed to determine perioperative morbidity and mortality as well as one-year mortality rates. Results Preoperative patient characteristics did not show any significant differences between groups. The simultaneous bilateral group had significantly longer operative times (127.4 versus 112.7 minutes, p Conclusions Two-team simultaneous total knee arthroplasty appears to be safe in obese patients, with similar complication rates as compared to unilateral procedures. Two-team simultaneous total knee arthroplasty also appears to have potential benefits over a staged procedure in the obese patient, although more study is required regarding this topic.

  12. The Silent Language of Fingers and Hands-The Role of Finger and Hand Motions in Non-verbal Communication

    Institute of Scientific and Technical Information of China (English)

    周樱

    2013-01-01

    This paper engages in the discussion about nonverbal intercultural communication from the perspective of hand and finger gestures, probing into the functions of non-verbal cues in cross-cultural interaction, talking over two different attitudes to⁃ward gestures, and giving a detailed analysis about the silent language of some specific gestures with fingers and hands in different cultures.

  13. The strength and function of hip abductors following anterolateral minimally invasive total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Tan Jixiang

    2014-04-01

    Full Text Available Objective: To analyze the extent of postoperative hip abductor insufficiency in primary total hip arthroplasty (THA patients undergoing anterolateral minimally invasive (ALMI approach, and to investigate whether the clinical outcomes are more favorable in femoral neck fracture (FNF patients than in non-femoral neck fracture (nFNF patients. Methods:A total of 48 patients were enrolled in this study. Each patient underwent a clinical examination preoperatively and 6, 12, 24 and 48 weeks postoperatively. The abductor torque, Trendelenburg's sign, gait velocity, Harris hip score, Oxford hip score, Westren Ontario and McMaster Universities (WOMAC score and visual analog scale pain score were recorded. Statistical evaluation was performed with SPSS software version 18.0. The significance level was set at P<0.05. Results:The abductor torque of the operated hip and the recovery ratio showed a gradual improving tendency from 6 weeks postoperatively until the last follow-up. Gait velocity, Harris hip score, Oxford hip score and WOMAC score improved significantly after the operation until 24 weeks postoperatively. In the FNF group, the abductor torque of the operated side and the recovery ratio were significantly higher than in nFNF group at 6 weeks postoperatively, however, as time passed, this trend tended to disappear. Conclusion:This study demonstrates that patients can obtain good abductor strength and function in the early postoperative period and the hip abductor function of patients who suffer from hip osteoarthritis, rheumatoid arthritis, avascular necrosis of the femoral head could be significantly improved following ALMI THA. Key words: Arthroplasty, replacement, hip; Surgical procedures, minimally invasive; Recovery of function

  14. The Inflammatory Phenotype in Failed Metal-On-Metal Hip Arthroplasty Correlates with Blood Metal Concentrations.

    Directory of Open Access Journals (Sweden)

    Erja-Leena Paukkeri

    Full Text Available Hip arthroplasty is the standard treatment of a painful hip destruction. The use of modern metal-on-metal (MOM bearing surfaces gained popularity in total hip arthroplasties during the last decade. Recently, worrisome failures due to adverse reaction to metal debris (ARMD, including pseudotumor response, have been widely reported. However, the pathogenesis of this reaction remains poorly understood. The aim of the present study was to investigate the ARMD response by flow cytometry approach.Sixteen patients with a failed Articular Surface Replacement (ASR hip prosthesis were included in the study. Samples of pseudotumor tissues collected during revision surgery were degraded by enzyme digestion and cells were typed by flow cytometry. Whole blood chromium and cobalt concentrations were analyzed with mass spectrometry before revision surgery.Flow cytometry analysis showed that the peri-implant pseudotumor tissue expressed two principal phenotypes, namely macrophage-dominated and T-lymphocyte-dominated response; the average portions being 54% (macrophages and 25% (T-lymphocytes in macrophage-dominated inflammation and 20% (macrophages and 54% (T-lymphocytes in T-lymphocyte-dominated response. The percentages of B-lymphocytes and granulocytes were lower in both phenotypes. Interestingly, the levels of blood chromium and cobalt were significantly higher in patients with macrophage-dominated response.The results suggest that the adverse tissue reactions induced by MOM wear particles contain heterogeneous pathogeneses and that the metal levels are an important factor in the determination of the inflammatory phenotype. The present results support the hypothesis that higher metal levels cause cytotoxicity and tissue injury and macrophages are recruited to clear the necrotic debris. On the other hand, the adverse response developed in association with lower metal levels is T-lymphocyte-dominated and is likely to reflect hypersensitivity reaction.

  15. The Inflammatory Phenotype in Failed Metal-On-Metal Hip Arthroplasty Correlates with Blood Metal Concentrations

    Science.gov (United States)

    Paukkeri, Erja-Leena; Korhonen, Riku; Hämäläinen, Mari; Pesu, Marko; Eskelinen, Antti; Moilanen, Teemu; Moilanen, Eeva

    2016-01-01

    Introduction Hip arthroplasty is the standard treatment of a painful hip destruction. The use of modern metal-on-metal (MOM) bearing surfaces gained popularity in total hip arthroplasties during the last decade. Recently, worrisome failures due to adverse reaction to metal debris (ARMD), including pseudotumor response, have been widely reported. However, the pathogenesis of this reaction remains poorly understood. The aim of the present study was to investigate the ARMD response by flow cytometry approach. Methods Sixteen patients with a failed Articular Surface Replacement (ASR) hip prosthesis were included in the study. Samples of pseudotumor tissues collected during revision surgery were degraded by enzyme digestion and cells were typed by flow cytometry. Whole blood chromium and cobalt concentrations were analyzed with mass spectrometry before revision surgery. Results Flow cytometry analysis showed that the peri-implant pseudotumor tissue expressed two principal phenotypes, namely macrophage-dominated and T-lymphocyte-dominated response; the average portions being 54% (macrophages) and 25% (T-lymphocytes) in macrophage-dominated inflammation and 20% (macrophages) and 54% (T-lymphocytes) in T-lymphocyte-dominated response. The percentages of B-lymphocytes and granulocytes were lower in both phenotypes. Interestingly, the levels of blood chromium and cobalt were significantly higher in patients with macrophage-dominated response. Conclusions The results suggest that the adverse tissue reactions induced by MOM wear particles contain heterogeneous pathogeneses and that the metal levels are an important factor in the determination of the inflammatory phenotype. The present results support the hypothesis that higher metal levels cause cytotoxicity and tissue injury and macrophages are recruited to clear the necrotic debris. On the other hand, the adverse response developed in association with lower metal levels is T-lymphocyte-dominated and is likely to reflect

  16. Importance of Attenuating Quadriceps Activation Deficits after Total Knee Arthroplasty

    OpenAIRE

    Thomas, Abbey C.; Jennifer E Stevens-Lapsley

    2012-01-01

    Total knee arthroplasty (TKA) is associated with persistent quadriceps dysfunction. Since quadriceps dysfunction impairs functional performance, minimizing quadriceps dysfunction by attenuating central activation deficits early after surgery may improve function later in life. Rehabilitation strategies incorporating neuromuscular electrical stimulation and early, aggressive quadriceps strengthening may prove beneficial. Further, surgical approaches such as minimally invasive TKA may minimize ...

  17. Outcome Assessment after Aptis Distal Radioulnar Joint (DRUJ Implant Arthroplasty

    Directory of Open Access Journals (Sweden)

    Amir Reza Kachooei

    2014-09-01

    Distal radioulnar joint injuries are disabling and patients usually undergo one or more salvage surgeries prior to receiving an arthroplasty. The Scheker prosthesis has shown satisfactory results with 100% survival rate in all reports. The constrained design of this prosthesis gives enough stability to prevent painful subluxation.

  18. Traditions and myths in hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Gromov, Kirill; Malchau, Henrik;

    2014-01-01

    NSAIDs, early mobilization, allowing early travel, and a low hemoglobin trigger for transfusion. Interpretation - Revision of traditions and myths surrounding hip and knee arthroplasty towards more contemporary evidence-based principles can be expected to improve early functional recovery, thus reducing...

  19. Early morbidity after simultaneous and staged bilateral total knee arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Jørgensen, Christoffer Calov; Husted, Henrik;

    2015-01-01

    PURPOSE: The aim of this nationwide study was to investigate the early morbidity after bilateral simultaneous and staged total knee arthroplasty (TKA) in order to clarify potential benefits of a well-established fast-track regime. METHODS: The Danish National Patient Registry was searched for all...

  20. Periprosthetic fractures of the femur after total knee arthroplasty

    OpenAIRE

    McGraw, Phil; Kumar, Arun

    2010-01-01

    Periprosthetic fracture following total knee arthroplasty is a potentially serious complication. This injury can involve the distal femur, proximal tibia or the patella. This review article analyzes the prevalence, risk factors, classification and treatment options for periprosthetic fractures of the femur.

  1. Compartment syndrome and popliteal vascular injury complicating unicompartmental knee arthroplasty

    NARCIS (Netherlands)

    Kort, Nanne Pieter; Van Raay, Jos J. J. A. M.; van Horn, Jim R.

    2007-01-01

    Popliteal vascular injury and the compartment syndrome of the leg are rare but important complications of knee arthroplasties. Early diagnosis and treatment are of paramount importance in preventing the devastating complications of these conditions. To our knowledge, these complications have not bee

  2. The role of shoulder fusion in the era of arthroplasty

    OpenAIRE

    González-Díaz, R.; Rodríguez-Merchán, E. C.; Gilbert, M. S.

    1997-01-01

    The indications, surgical techniques, results and complications of shoulder fusion are described. The indications are bacterial infection, paralytic disorders in infancy, combined deltoid and rotator cuff paralysis, post-traumatic brachial plexus lesions, inflammatory arthritis with severe rotator cuff involvement, failed arthroplasty, recurrent dislocation, after resection of tumours, irreparable rotator cuff tear, painful arthritis in a patient whose activities requi...

  3. Low manipulation prevalence following fast-track total knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Jørgensen, Christoffer C.; Gromov, Kirill;

    2015-01-01

    Background and purpose - Postoperative joint stiffness following total knee arthroplasty (TKA) may compromise the outcome and necessitate manipulation. Previous studies have not been in a fast-track setting with optimized pain treatment, early mobilization, and short length of stay (LOS), which m...

  4. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty : design of a randomized controlled trial

    NARCIS (Netherlands)

    Zijlstra, Wierd P.; Bos, Nanne; van Raaij, Jos J. A. M.

    2008-01-01

    Background: Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyet

  5. Unilateral vs one stage bilateral total knee replacement in rheumatoid and osteoarthritis - A comparative study

    Directory of Open Access Journals (Sweden)

    Kiran E

    2005-01-01

    Full Text Available Background : A controversy exists regarding simultaneous or staged bilateral total knee replacement. Methods: Fifty patients undergoing simultaneous bilateral and 50 undergoing unilateral total knee arthroplasty were evaluated prospectively to compare the clinical, radiological results and complication rates. Eighty-four patients belonged to ASA category II or III preoperatively. The study included a high proportion of rheumatoid patients and osteoarthritis patients with severe deformities. Results: Bilateral group had greater blood loss and required more blood transfusion, but there was no difference in requirement of postoperative intensive care and the complication rates. Rheumatoid knees had lower pre and postoperative knee score and functional score as compared to osteoarthritic knees. Morbidity and mortality of one stage bilateral knee replacement was no greater than unilateral operation. Conclusion: Simultaneous bilateral knee replacement in younger patients with advanced rheumatoid arthritis is safe and effective

  6. Torque control of underactuated tendon-driven fingers

    Directory of Open Access Journals (Sweden)

    M. E. Abdallah

    2011-02-01

    Full Text Available Given an underactuated tendon-driven finger, the finger posture is underdetermined and can move freely ("flop" in a region of slack tendons. This work shows that such an underactuated finger can be operated in tendon force control (rather than position control with effective performance. The force control eliminates the indeterminate slack while commanding a parameterized space of desired torques. The torque will either push the finger to the joint limits or wrap around an external object with variable torque – behavior that is sufficient for primarily gripping fingers. In addition, introducing asymmetric joint radii to the design allows the finger to command an expanded range of joint torques and to scan an expanded set of external surfaces. This study is motivated by the design and control of the secondary fingers of the NASA-GM R2 humanoid hand.

    This paper was presented at the IFToMM/ASME International Workshop on Underactuated Grasping (UG2010, 19 August 2010, Montréal, Canada.

  7. EFFECT OF PROPRIOCEPTIVE EXERCISES IN OSTEOARTHRITIC AND REPLACED KNEES

    Directory of Open Access Journals (Sweden)

    Santosh Metgud

    2015-12-01

    Full Text Available Background: Osteoarthritis is a degenerative joint disease involving thinning or destruction of the smooth cartilage that covers the ends of bones and changes to the bone. Joint arthroplasty is an intervention for those patients who have severe disease, with severe pain and radiographic evidence. Objective: To compare the effect of proprioceptive exercises in osteoarthritic and total replaced knees using the Knee Society Score and Joint Position Sense. Design: A randomised clinical trial. Subjects: A total of 95 subjects were selected based on the inclusion and exclusion criteria. Intervention: Participants were divided into two groups; Group A comprised of the Total Knee Replacement and Group B was the osteoarthritic group. Group A was given exercises along with ambulation and static and resistance cycling and training of functional activities. Group B was given exercises and seven proprioceptive exercises followed by continuous short wave diathermy cross-fire method for 15 minutes. Outcome measure: Pain Intensity, Functional Outcome and Joint Position Sense (JPS were measured by using Visual Analog Scale (VAS, Knee Society Score (KSS and Absolute angle of error, respectively. Results: The results show a significant difference between the two groups using VAS and JPS whereas showed no significant difference between the two groups on using the KSS. Conclusion: Based on the results of this study, it was observed that proprioceptive exercises are beneficial in improving the joint position sense in patients with osteoarthritis as well as total knee replacements.

  8. Application of cervical arthroplasty with Bryan cervical disc:long-term X-ray and magnetic resonance imaging follow-up results

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yan-bin; SUN Yu; CHEN Zhong-qiang; LIU Zhong-jun

    2010-01-01

    Background Cervical disc arthroplasty is a new technique for treating degenerative cervical disease. Its goal is to avoid the degeneration of adjacent levels by preserving motion at the treated level. The aims of this study were to evaluate the radiologic outcomes of Bryan cervical disc replacement and the degenerative status of adjacent segments.Methods Twenty-two patients at a single center underwent discectomy and implantation of Bryan cervical disc. The mean follow-up period was 60 months (57-69 months). Twenty patients underwent single-level arthroplasty and two underwent arthroplasty at two levels. The levels of surgery included C3/4 (3 levels), C4/5 (2 levels), C5/6 (18 levels) and C6/7 (1 level). Radiographic evaluation included dynamic X-ray examination and magnetic resonance imaging (MRI) at baseline and at final follow-up.Results On X-ray examination, the range of motion (ROM) at the operated level was 7.2° (2.5°-13.0°) at baseline and 7.8° (1.0°-15.0°) at final follow-up (P >0.05). Heterotopic ossification around the prosthesis was observed in eight levels,and two levels showed loss of motion (ROM <2°). MRI showed worsening by a grade at the upper level in 2/22 patients,and worsening by a grade at the lower level in 3/22, according to Miyazaki's classification. No further impingement of the ligamentum flavum into the spinal canal was observed at adjacent levels, though the disc bulge was slightly increased at both the adjacent upper and lower levels at final follow-up.Conclusions Arthroplasty using Bryan cervical disc prosthesis resulted in favorable radiologic outcomes in this study.Disc degeneration at adjacent levels may be postponed by this technique.

  9. Periprosthetic fracture-dislocation in a loosened total knee replacement treated by knee arthrodesis

    International Nuclear Information System (INIS)

    We present a patient who was operated four years before performing a total knee replacement. She fell down resulting a periprosthetic femoral fracture and a prosthetic dislocation. After evaluating different treatments, we decided to do prosthetic removal and a knee arthrodesis using an intramedullar nail. The femoral fracture was fixed with wire cerclages. Knee arthrodesis is a procedure uses as a last option for the treatment of infected or loosed arthroplasties. In our case it was difficult to consider any other reconstructive procedure due to the association of fracture, dislocation and loosening. The evolution has been satisfactory with good functional result and without pain

  10. The patient's experience of temporary paralysis from spinal anaesthesia, a part of total knee replacement

    DEFF Research Database (Denmark)

    Bager, Louise; Konradsen, Hanne; Dreyer, Pia Sander

    the experience of spinal anaesthesia, as a part of having a total knee replacement. METHODS: Twelve patients were interviewed in March 2014 after undergoing an elective total knee arthroplasty under spinal anaesthesia. The interviews were analysed with a Ricoeur-inspired interpretation method. RESULTS......: Three themes were derived from the interviews: 'anaesthesia - an unavoidable necessity', 'an unrecognisable and incomprehensible body' and 'the body returns - joy and agony'. CONCLUSION: The results reveal that trust in the health care personnel and knowledge of the course of events play a key role in...

  11. Magnetic resonance imaging features of complications following hip replacement: A pictorial review

    Directory of Open Access Journals (Sweden)

    Khushboo Pilania

    2016-01-01

    Full Text Available Hip replacement surgery helps millions of people worldwide walk painlessly each year. With increasing life spans and decreased clinical threshold for surgery, this number will continue to rise. With the increase in the number of surgeries and the longevity of implants, the need for early and prompt diagnosis of complications is also rising. This essay underlines the fact that magnetic resonance imaging on a 1.5T scanner with specialized metal artefact reduction sequences is a viable technique to image the post-arthroplasty hip and has vast potential in the prompt and early diagnosis of complications in these patients.

  12. Total Hip Arthroplasty for Hip Fractures

    Science.gov (United States)

    Monzón, Daniel Godoy; Iserson, Kenneth V.; Jauregui, José; Musso, Carlos; Piccaluga, Francisco; Buttaro, Martin

    2014-01-01

    Introduction: This study aimed to determine the dislocation and reoperation rate, functional outcomes, and the survival rate of the unique subset of very old but lucid and independent patients with hip fractures following a total hip arthroplasty (THA) and geriatric team-coordinated perioperative care. Method: Between 2000 and 2006, previously independent ambulatory patients ≥80 years old presenting with an intracapsular hip fracture were given THAs under the care of an integrated orthopedic surgery–geriatric service. Their fracture-related complications, ambulation, mental status, and survival were followed for 5 to 11 years postinjury. Results: Five years postinjury, 57 (61.3%) patients of the original study group were living. In all, 3 (3.2%) patients had postoperative hip dislocations (and 2 patients had dislocation twice) and 2 reoperations were needed within the first postoperative month. There were no hip dislocations or reoperations after the first year. Radiographs obtained on 88% of the surviving patients at 5 years postoperatively showed that all remained unchanged from their immediate postoperative images. Nearly half of the patients were still able to ambulate as they did preoperatively and their mixed-model equation was statistically unchanged. Conclusion: This study of patients >80 years old with previously good functional status demonstrates that with appropriate surgical (best prosthesis, good operating technique, and regional anesthesia) and geriatric (pre- and postoperative assessments, close follow-up, medication adjustments, and fall-prevention instruction) care, they have few hip dislocations and reoperations, survive postfracture at least as long as their noninjured contemporaries, and continue to function and ambulate as they did prior to their injury. PMID:24660092

  13. Infected total knee arthroplasty treatment outcome analysis

    Directory of Open Access Journals (Sweden)

    Radoičić Dragan

    2012-01-01

    Full Text Available Background/Aim. Infected total knee arthroplasty (TKA is a topic of great importance, because its diagnosing and treatment requires a lot of resources, and often has an unsatisfactory outcome. The aim of this study was to analyze the outcome of the treatment of infection developed following TKA. Methods. This retrospective study of infected TKAs was performed in the period from 1998 to 2008 in the Orthopedics & Traumatology Clinic of the Military Medical Academy (MMA in Belgrade. A total of 654 primary and revised TKAs were performed in the said period. We registered and surgically treated 28 infected TKAs (primary TKAs: MMA - 22, other institutions - 6. The incidence of TKA infection in the MMA was 3.36%. The most common pathogens were: Staphylococcus aureus - 14 (50% cases, and Staph. epidermidis - 3 (10.7% cases. Other isolated pathogens were: Enterococcus faecalis, Klebsiella pneum., Klebsiella spp., Streptoccocus viridans, Seratia spp, Micrococcus luteus and Peptostreptococcus spp. In one case we had mixed anaerobic flora, and in 3 cases cultures were negative. We analyzed diagnostic challenges, risk factors (such as age and previous viscosupplementation and treatment outcomes in our series of infected TKAs. Results. In our series 2 infections healed after iv antibiotics and debridement, 1 patient responded to open debridement with component retention, 4 patients responded fully to one-stage reimplantation, 10 cases responded fully to two-stage reimplantation, 11 patients ended with arthrodesis and we had 1 patient with above knee amputation. Conclusion. Two-stage reimplantation remains gold standard for treatment of infected TKA, and we recommend it as treatment of choice for eradication of infection. The antibiotic loaded spacer prothesis concept in most cases allows infection eradication, good function and high patient satisfaction.

  14. Future bearing surfaces in total hip arthroplasty.

    Science.gov (United States)

    Chang, Jun-Dong

    2014-03-01

    One of the most important issues in the modern total hip arthroplasty (THA) is the bearing surface. Extensive research on bearing surfaces is being conducted to seek an ideal bearing surface for THA. The ideal bearing surface for THA should have superior wear characteristics and should be durable, bio-inert, cost-effective, and easy to implant. However, bearing surfaces that are currently being implemented do not completely fulfill these requirements, especially for young individuals for whom implant longevity is paramount. Even though various new bearing surfaces have been investigated, research is still ongoing, and only short-term results have been reported from clinical trials. Future bearing surfaces can be developed in the following ways: (1) change in design, (2) further improvement of polyethylene, (3) surface modification of the metal, (4) improvement in the ceramic, and (5) use of alternative, new materials. One way to reduce wear and impingement in THA is to make changes in its design by using a large femoral head, a monobloc metal shell with preassembled ceramic liner, dual mobility cups, a combination of different bearing surfaces, etc. Polyethylene has improved over time with the development of highly crosslinked polyethylene. Further improvements can be made by reinforcing it with vitamin E or multiwalled carbon nanotubes and by performing a surface modification with a biomembrane. Surface modifications with titanium nitride or titanium niobium nitride are implemented to try to improve the metal bearings. The advance to the fourth generation ceramics has shown relatively promising results, even in young patients. Nevertheless, further improvement is required to reduce fragility and squeaking. Alternative materials like diamond coatings on surfaces, carbon based composite materials, oxidized zirconium, silicon nitride, and sapphire are being sought. However, long-term studies are necessary to confirm the efficacy of these surfaces after enhancements

  15. Product Platform Replacements

    DEFF Research Database (Denmark)

    Sköld, Martin; Karlsson, Christer

    2012-01-01

    shed light on this unexplored and growing managerial concern, the purpose of this explorative study is to identify operational challenges to management when product platforms are replaced. Design/methodology/approach – The study uses a longitudinal field-study approach. Two companies, Gamma and Omega......Purpose – It is argued in this article that too little is known about product platforms and how to deal with them from a manager's point of view. Specifically, little information exists regarding when old established platforms are replaced by new generations in R&D and production environments. To...... distinguishing between platform replacement “height” and “width”. Seven groups of managerial measures for dealing with the issues are recommended. Originality/value – The study aims to contribute to the existing literature by taking a managers' perspective of product platform development. Its specific...

  16. Method and effect of total knee arthroplasty osteotomy and soft tissue release for serious knee joint space narrowing

    Directory of Open Access Journals (Sweden)

    Yulou Si

    2015-01-01

    Full Text Available To discuss the method and effect of total knee arthroplasty osteotomy and soft tissue release for serious knee joint space narrowing. Clinical data of 80 patients from October 2013 to December 2014 was selected with a retrospective method. All patients have undergone total knee arthroplasty. Then the X-rays plain film in weight loading was measured before and after operation and osteotomy was performed accurately according to the knee joint scores and the conditions of lower limb alignments. The average angle of tibial plateau osteotomy of postoperative patients was 4.3°, and the corrective angle of soft tissue balancing was 10.7°; the postoperative patients’ indicies including range of joint motion, knee joint HSS score, angle between articular surfaces, tibial angle, femoral-tibial angle and flexion contracture were distinctly better than the preoperative indicies (p<0.05 and the differences were statistically significant; the postoperative patients’ flexion contracture and range of joint motion were distinctly better than the preoperative indicies (p<0.05 and the differences were statistically significant. The effective release of the soft tissue of the posterior joint capsule under direct vision can avoid excess osteotomy and get satisfactory knee replacement space without influencing the patients’ joint recovery.

  17. Idiopathic Cardiomyopathy Following Metal-on-Metal Hip Arthroplasty: The New Face of “Beer Drinker’s Cardiomyopathy”

    Directory of Open Access Journals (Sweden)

    Erik O’Connell,

    2013-01-01

    Full Text Available In 1966, the “beer drinker’s cardiomyopathy” was described in Quebec City, Canada among heavy drinkers following the addition of cobalt by breweries for foam stabilisation. Almost half of those affected died. A similar process has been proposed for cardiovascular periprosthetic metallosis in patients receiving cobalt-containing hip prostheses. This case describes a young man with congenital osteonecrosis treated with cobalt containing prosthetic arthroplasty. Postoperatively, he developed pericardial effusion, dilated cardiomyopathy, polycythemia and lactic acidosis. His serum cobalt level was 156 mcg/L ( normal 0.1 – 0.4 mcg/L. Metal-on-metal hip implants have been associated with arthroprosthetic cobaltisim, a presentation indistinguishable from “beer drinker’s cardiomyopathy.” Up to 35% of hip replacements utilize metal-on-metal bearing surfaces, making this a potentially wide-spread and relatively underappreciated etiology of postoperative idiopathic cardiomyopathy. This clinical vignette emphasizes the importance of considering cobalt cardio- toxicity, or “beer drinker’s cardiomyopathy,” as a differential diagnosis of idiopathic cardiomyopathy following total hip arthroplasty.

  18. Incidence of Heterotopic Ossification after Surface and Conventional Total Hip Arthroplasty: A Comparative Study Using Anterolateral Approach and Indomethacin Prophylaxis

    Directory of Open Access Journals (Sweden)

    Dario Regis

    2013-01-01

    Full Text Available The incidence and severity of heterotopic ossification (HO in two homogeneous groups of patients that received surface replacement arthroplasty (SRA and conventional total hip arthroplasty (THA were evaluated retrospectively. Thirty-nine patients undergoing 42 hip resurfacing procedures and 41 primary cementless THAs through an anterolateral approach received a 10-day course of 150 mg/die of indomethacin postoperatively. The median surgical time was 190 minutes and 156 minutes, respectively (. At a minimum 1-year followup, the development of HO was assessed on standard X-ray using Brooker grading. Ectopic bone formation was detected in five cases (11.9%, two Brooker grade I and three grade II in the SRA group and in 14 hips (34.1%, 12 grade I and two grade II treated with conventional THA, but the difference was not significant (. No clinically relevant periprosthetic ossification (Brooker III or IV occurred in both groups. Although the difference was not statistically significant, the incidence of HO after SRA was lower than conventional THA. More extensive soft tissue trauma, bone debris, and longer operative time in hip resurfacing are not likely to be absolute risk factors for HO. Further investigations including larger patient populations are needed to confirm these findings.

  19. A reduced model for fingering instability in miscible displacement

    International Nuclear Information System (INIS)

    The classical problem of fingering instability in miscible displacement is revisited. The finger-forming dynamics is considered as a multiple-scale process involving a thin inter-diffusion layer and large-scale background flow affected by the viscosity and/or density stratification. Upon an appropriate separation of 'fast' and 'slow' variables one ends up with a reduced model dealing directly with the evolving displacement front. As an illustration, the new model is applied for description of fingering in a source-supported flow and in a flow within a vertical channel

  20. Dorsal finger texture recognition: Investigating fixed-length SURF

    DEFF Research Database (Denmark)

    Hartung, Daniel; Kückelhahn, Jesper

    2012-01-01

    We seek to create fixed-length features from dorsal finger skin images extracted by the SURF interest point detector to combine it in the privacy enhancing helper data scheme. The source of the biometric samples is the GUC45 database which features finger vein, fingerprint and dorsal finger skin...... images for modality fusion. First, the region of interest (ROI) is extracted, after which SURF features are extracted, and finally two different approaches for creating fixed length feature vectors are applied. SURF performance on the ROI is comparable to the PolyU database reported in the literature...

  1. A hierarchical classification method for finger knuckle print recognition

    Science.gov (United States)

    Kong, Tao; Yang, Gongping; Yang, Lu

    2014-12-01

    Finger knuckle print has recently been seen as an effective biometric technique. In this paper, we propose a hierarchical classification method for finger knuckle print recognition, which is rooted in traditional score-level fusion methods. In the proposed method, we firstly take Gabor feature as the basic feature for finger knuckle print recognition and then a new decision rule is defined based on the predefined threshold. Finally, the minor feature speeded-up robust feature is conducted for these users, who cannot be recognized by the basic feature. Extensive experiments are performed to evaluate the proposed method, and experimental results show that it can achieve a promising performance.

  2. Finger Movement Based Wearable Communication & Navigation Aid for partially disabled

    Directory of Open Access Journals (Sweden)

    Jobin Jose

    2016-02-01

    Full Text Available The FMBWCN Aid is a portable and wearable multi-purpose system for the partially disabled. The Aid is a glove-based system in which different trained finger movements leads to different modes of operation of the system such as APR Voice Module and Wheelchair Controller Module. The finger movements (bending movement leads to the flexion of the flex sensor attached to the glove. Flexion leads to change in resistance of the flex sensors, which will be recorded via a microcontroller (Arduino Uno and different sets of movement of the fingers will lead to different modules of operation as specified in the default settings of the FMBWCN Aid.

  3. Finger milling-cutter CNC generating hypoid pinion tooth surfaces based on modified-roll method and machining simulation

    Science.gov (United States)

    Li, Genggeng; Deng, Xiaozhong; Wei, Bingyang; Lei, Baozhen

    2011-05-01

    The two coordinate systems of cradle-type hypoid generator and free-form CNC machine tool by application disc milling-cutter to generate hypoid pinion tooth surfaces based on the modified-roll method were set up, respectively, and transformation principle and method for machine-tool settings between the two coordinate systems was studied. It was presented that finger milling-cutter was mounted on imagined disc milling-cutter and its motion was controlled directly by CNC shafts to replace disc milling-cutter blades effective cutting motion. Finger milling-cutter generation accomplished by ordered circular interpolation was determined, and interpolation center, starting and ending were worked out. Finally, a hypoid pinion was virtually machined by using CNC machining simulation software VERICUT.

  4. TOTAL KNEE ARTHROPLASTY IN A PATIENT WITH HOFFA FRACTURE PSEUDARTHROSIS: CASE REPORT

    OpenAIRE

    Rodrigo Pires e Albuquerque; Giordano, Vincenzo; Amaral, Ney Pecegueiro do; Carvalho, Antônio Carlos Pires; Barretto, João Maurício

    2015-01-01

    A rare occurrence of a case of Hoffa fracture pseudarthrosis in an alcoholic patient with genu valgum associated with venous insufficiency who underwent total knee arthroplasty is reported. The literature is reviewed and the main factors for surgical indication of total knee arthroplasty after a fracture of the knee are discussed. Total knee arthroplasty was a viable option in a 60-year-old patient with Hoffa fracture pseudarthrosis and comorbidities.

  5. Revision to reverse shoulder arthroplasty with retention of the humeral component

    OpenAIRE

    Werner, Birgit S.; Boehm, Dorota; Gohlke, Frank

    2013-01-01

    Background Revision in failed shoulder arthroplasty often requires removal of the humeral component with a significant risk of fracture and bone loss. Newer modular systems allow conversion from anatomic to reverse shoulder arthroplasty with retention of a well-fixed humeral stem. We report on a prospectively evaluated series of conversions from hemiarthroplasty to reverse shoulder arthroplasty. Methods In 14 cases of failed hemiarthroplasty due to rotator cuff deficiency and painful pseudopa...

  6. Atraumatic patellar prosthesis dislocation with patellar tendon injury following a total knee arthroplasty: a case report

    OpenAIRE

    Singh Alka; Singh Yashwant; Singh Pankaj; Singh Vinay; Javed Sadaf; Abdunabi Murad

    2010-01-01

    Abstract Introduction Total knee arthroplasty is a well-established procedure with gratifying results. There is no consensus in the literature whether to routinely resurface the patella while performing total knee arthroplasty or not. Although an extremely rare occurrence in clinical practice, patellar prosthesis dislocation is a possible complication resulting from total knee arthroplasty. Case presentation We report a rare case of atraumatic spontaneous dislocation of patellar prosthesis in...

  7. Replacing a Missing Tooth

    Science.gov (United States)

    ... the extra bulk and removable nature of the partial denture and report that it feels unnatural. This type of prosthesis is best as a temporary replacement as described above. The second option in a patient without a bone graft is a fixed bridge. The missing tooth is restored with an ...

  8. Fast track in total hip and knee arthroplasty--experiences from Hvidovre University Hospital, Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte

    2006-01-01

    This study investigated whether unselected patients operated on with total hip arthroplasty (THA) or total knee arthroplasty (TKA) could accomplish a self-developed accelerated track, ANORAK-HH, with a planned length of stay (LOS) of maximum 5 days and patient satisfaction at all parts of the track....... 307 patients who sustained 329 hip and knee arthroplasties were included in the study with the main material constituted from 243 primary unilateral THA and TKA arthroplasties. ANORAK-HH includes pre-operative patient clinic, patient motivation, dedicated staff, unchanged criteria for discharge and a...

  9. Finger Length Ratios in Serbian Transsexuals

    Science.gov (United States)

    Vujović, Svetlana; Popović, Srdjan; Mrvošević Marojević, Ljiljana; Ivović, Miomira; Tančić-Gajić, Milina; Stojanović, Miloš; Marina, Ljiljana V.; Barać, Marija; Barać, Branko; Kovačević, Milena; Duišin, Dragana; Barišić, Jasmina; Djordjević, Miroslav L.; Micić, Dragan

    2014-01-01

    Atypical prenatal hormone exposure could be a factor in the development of transsexualism. There is evidence that the 2nd and 4th digit ratio (2D : 4D) associates negatively with prenatal testosterone and positively with estrogens. The aim was to assess the difference in 2D : 4D between female to male transsexuals (FMT) and male to female transsexuals (MFT) and controls. We examined 42 MFT, 38 FMT, and 45 control males and 48 control females. Precise measurements were made by X-rays at the ventral surface of both hands from the basal crease of the digit to the tip using vernier calliper. Control male and female patients had larger 2D : 4D of the right hand when compared to the left hand. Control male's left hand ratio was lower than in control female's left hand. There was no difference in 2D : 4D between MFT and control males. MFT showed similar 2D : 4D of the right hand with control women indicating possible influencing factor in embryogenesis and consequently finger length changes. FMT showed the lowest 2D : 4D of the left hand when compared to the control males and females. Results of our study go in favour of the biological aetiology of transsexualism. PMID:24982993

  10. Online Credit Card Transaction Using Finger Print Recognition

    Directory of Open Access Journals (Sweden)

    S.Sivasubramanian

    2010-10-01

    Full Text Available Internet shopping, a strong alternative to traditional “go, see, touch and buy” shopping, has been one of the mostly used facilities of the Internet. Security in online payment systems has been a wide research area since the early days of the Internet and several approaches have been devised by various Organizations. But, none of the system overcome the weakness in those system. Several online shopping systems serve internet users all around the world and enable people to get the products they need with a small effort. This paper proposes a new solution that combines finger print recognition with online credit card transactions. Here the proposed system provides more security then existing system with finger print recognitionbecause of finger print is unique. Here no need to remember the more passwords, your finger is your password.

  11. Possible Gigantic Variations on the Width of Viscoelastic Fingers

    CERN Document Server

    Poire, E C; Poire, Eugenia Corvera

    2002-01-01

    We analyze the effect of frequency on the width of a single finger displacing a viscoelastic fluid. We derive a generalized Darcy's law in the frequency domain for a linear viscoelastic fluid flowing in a Hele Shaw cell. This leads to an analytic expression for the dynamic permeability that has maxima which are several orders of magnitude larger than the static permeability. We then follow an argument of de Gennes to obtain the smallest possible finger width when viscoelasticity is important. Using this, and a conservation law, we obtain a lowest bound for the width of a single finger displacing a viscoelastic fluid. Our results indicate that when a small amplitude signal of the frequency that maximizes the permeability is overimposed to a constant pressure drop, gigantic variations are obtained for the finger width.

  12. An analysis of issues in biometric finger identification

    Directory of Open Access Journals (Sweden)

    Nanda Kumar Veerasamy

    2014-06-01

    Full Text Available A Person's identity is an essential factor in this vastly connected society. Biometric Finger has wide acceptance as a genuine method for determining an individual’s identity. Biometric Finger authentication is reliable, since physical characteristics in humans are difficult to forge, harder to change or make copies. Biometric fingerprinting is one of the most popular and legally accepted biometrics used in person identification. Finger print authentication applications include Computer Applications, Network Access, Data Protection, Transaction Security, and Web Security. E-commerce and E-governments can carry out strong authentication rules. This paper analyzes issues related to Fingerprint identification to suggest viable alternatives. Keywords: Fingerprint Identification, Optical Sensors, Ultrasound Sensors, Issues in Finger Print Identification.

  13. Dose-response patterns for vibration-induced white finger

    OpenAIRE

    Griffin, M; Bovenzi, M.; Nelson, C

    2003-01-01

    Aims: To investigate alternative relations between cumulative exposures to hand-transmitted vibration (taking account of vibration magnitude, lifetime exposure duration, and frequency of vibration) and the development of white finger (Raynaud's phenomenon).

  14. Finger blood content, light transmission, and pulse oximetry errors.

    Science.gov (United States)

    Craft, T M; Lawson, R A; Young, J D

    1992-01-01

    The changes in light emitting diode current necessary to maintain a constant level of light incident upon a photodetector were measured in 20 volunteers at the two wavelengths employed by pulse oximeters. Three states of finger blood content were assessed; exsanguinated, hyperaemic, and normal. The changes in light emitting diode current with changes in finger blood content were small and are not thought to represent a significant source of error in saturation as measured by pulse oximetry. PMID:1536406

  15. Unveiling the Biometric Potential of Finger-Based ECG Signals

    OpenAIRE

    André Lourenço; Hugo Silva; Ana Fred

    2011-01-01

    The ECG signal has been shown to contain relevant information for human identification. Even though results validate the potential of these signals, data acquisition methods and apparatus explored so far compromise user acceptability, requiring the acquisition of ECG at the chest. In this paper, we propose a finger-based ECG biometric system, that uses signals collected at the fingers, through a minimally intrusive 1-lead ECG setup recurring to Ag/AgCl electrodes without gel as interface with...

  16. Viscous and Gravitational Fingering in Multiphase Compositional and Compressible Flow

    OpenAIRE

    Moortgat, Joachim

    2016-01-01

    Viscous and gravitational fingering refer to flow instabilities in porous media that are triggered by adverse mobility or density ratios, respectively. These instabilities have been studied extensively in the past for 1) single-phase flow (e.g., contaminant transport in groundwater, first-contact-miscible displacement of oil by gas in hydrocarbon production), and 2) multi-phase immiscible and incompressible flow (e.g., water-alternating-gas (WAG) injection in oil reservoirs). Fingering in mul...

  17. Dynamic analysis of C/C composite finger seal

    OpenAIRE

    Chen Guoding; Wang Li’na; Yu Qiangpeng; Su Hua

    2014-01-01

    A seal device as an important component of aeroengines has decisive influence on performance, reliability, and working life of aeroengines. With the development of aeroengines, demands on the performance characteristics of seal devices are made strictly. Finger seal as a novel kind of sealing device, recently attracts more and more attentions in academic circles and engineering fields at home and abroad. Research on finger seals has been extensively developed, especially on leakage and wear p...

  18. Finger avulsion injuries: A report of four cases

    Directory of Open Access Journals (Sweden)

    Fejjal N

    2008-01-01

    Full Text Available Injury that occurs to a finger wearing a ring though rare can have grave consequences. It is a preventable injury which has a peculiar mode of trauma that is usually occupational. Injury ranges from simple contusion to degloving of soft tissues to traumatic amputation. We hereby report our experience of four cases of finger avulsion injuries due to a ring and discuss their variable clinical presentation and individualized management.

  19. Prevalence of finger sucking at preschool children in Bitola

    OpenAIRE

    Domnika Rajchanovska; Beti Zafirova Ivanovska

    2014-01-01

    The aim of the study was to establish the prevalence of the habit,finger sucking at pre school children in Bitola. observational cross-sectional study conducted and 1607 children from 3 to 5 years old were included. The following methods were applied: psychological testing (Test of Chuturik), clinical pediatric examination, interview with the parents and survey Child Behavior Checklist-Achenbach, 1981. The results shows that the prevalence of the habit finger sucking at the examinees was 24...

  20. Speed-stability paradox in DNA-scanning by zinc-finger proteins

    OpenAIRE

    Iwahara, Junji; Levy, Yaakov

    2013-01-01

    Extensive contact with DNA via multiple zinc fingers allows highly specific DNA-binding of zinc-finger-class transcription factors, but can also slow the target search process. Here we introduce recent insights into how zinc-finger proteins can rapidly scan DNA. Potential application of the new knowledge to the zinc-finger-based technology is also discussed.

  1. Stress Distribution in Implant Retained Finger Prosthesis: A Finite Element Study

    OpenAIRE

    Amornvit, Pokpong; Rokaya, Dinesh; Keawcharoen, Konrawee; Thongpulsawasdi, Nimit

    2013-01-01

    Background: Finger amputation may result from congenital cause, trauma, infection and tumours. The finger amputation may be rehabilitated with dental implant-retained finger prosthesis. The success of implant-retained finger prosthesis is determined by the implant loading. The type of the force is a determining factor in implant loading.

  2. Femoral component loosening after hip resurfacing arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Zustin, Jozef; Sauter, Guido [University Medical Centre Hamburg-Eppendorf, Institute of Pathology, Hamburg (Germany); Hahn, Michael [University Medical Centre Hamburg-Eppendorf, Center for Biomechanics and Skeletal Biology, Hamburg (Germany); Morlock, Michael M. [TUHH Hamburg University of Technology, Biomechanics Section, Hamburg (Germany); Ruether, Wolfgang [University Medical Centre Hamburg-Eppendorf, Department of Orthopaedics, Hamburg (Germany); Amling, Michael [University Medical Centre Hamburg-Eppendorf, Center for Biomechanics and Skeletal Biology, Hamburg (Germany); University Medical Centre Hamburg-Eppendorf, Department of Trauma, Hand and Reconstructive Surgery, Hamburg (Germany)

    2010-08-15

    Before the re-introduction of the current generation of total hip resurfacing arthroplasty, component loosening and osteolysis were of great concern to the orthopaedic community. Early, mid- and long-term clinical results are encouraging, but component loosening still exists. Macroscopic, contact radiographic and histopathological analyses after undecalcified preparation of bone tissue specimens were performed. To investigate the frequency and morphological patterns of the loosening of the femoral component, we analysed a series of 190 retrieved femoral remnants that were revised for aseptic failures. Thirty-five (18.4%) hips were revised for clinical and/or radiographic loosening of the femoral component. Pseudoarthrosis (n = 17; median in situ time: 16 weeks, interquartile range [IQR]: 9 to 34), collapsed osteonecrosis (n = 5; median in situ time: 79 weeks, IQR: 63 to 97), cement-socket debonding (n = 3; median in situ time: 89 weeks, IQR: 54 to 97) and at later follow-up bone-cement loosening (n = 10; median in situ time: 175 weeks; IQR 112 to 198; p =0.005) were distinct patterns of the femoral remnant-implant loosening. Fibrocartilaginous metaplasia of interface bone trabeculae (n = 38; median in situ time: 61 weeks, IQR: 32 to 138) was strongly associated with femoral component loosening (p = 0.009). Both the trabecular hyperosteoidosis (n = 32; median in situ time: 71 weeks, IQR 50 to 129) and excessive intraosseous lymphocyte infiltration (n = 12; median in situ time: 75 weeks, IQR 51 to 98) at the bone-cement interface correlated strongly with fibrocartilaginous metaplasia (p = 0.001 and p = 0.016 respectively) and all three lesions were associated with the female gender (p = 0.021, p = 0.009, and p = 0.051). Femoral component loosening at early follow-up was mostly caused by pathological changes of the femoral remnant bone tissue: pseudoarthrosis and collapsed osteonecrosis. Fibrocartilaginous metaplasia was frequently observed in hips with femoral

  3. Elastic fingering in rotating Hele-Shaw flows

    KAUST Repository

    Carvalho, Gabriel D.

    2014-05-21

    The centrifugally driven viscous fingering problem arises when two immiscible fluids of different densities flow in a rotating Hele-Shaw cell. In this conventional setting an interplay between capillary and centrifugal forces makes the fluid-fluid interface unstable, leading to the formation of fingered structures that compete dynamically and reach different lengths. In this context, it is known that finger competition is very sensitive to changes in the viscosity contrast between the fluids. We study a variant of such a rotating flow problem where the fluids react and produce a gellike phase at their separating boundary. This interface is assumed to be elastic, presenting a curvature-dependent bending rigidity. A perturbative weakly nonlinear approach is used to investigate how the elastic nature of the interface affects finger competition events. Our results unveil a very different dynamic scenario, in which finger length variability is not regulated by the viscosity contrast, but rather determined by two controlling quantities: a characteristic radius and a rigidity fraction parameter. By properly tuning these quantities one can describe a whole range of finger competition behaviors even if the viscosity contrast is kept unchanged. © 2014 American Physical Society.

  4. Fluidic Channels Produced by Electro Hydrodynamic Viscous Fingering

    Science.gov (United States)

    Behler, Kristopher; Wetzel, Eric

    2010-03-01

    Viscous fingering is a term describing fingerlike extensions of liquid from a column of low viscosity liquid that has been injected into a more viscous liquid. The modification of viscous fingering, known as electro hydrodynamic viscous fingering (EHVF), utilizes large electrical potentials of 10-60 kV. The fingers see a reduction in size and increase in branching behavior due to the potential applied to the system. The resulting finely structured patterns are analogous to biological systems such as blood vessels and the lymphatic system. In this study silicone oils and water were studied in thin channel Hele-Shaw cells. The interfacial tension was optimized by altering the surfactant concentration in the silicone oils. EHVF of liquid filled packed beds consisting of beads and silicone oils showed retardation of the relaxation of the fingers after the voltage was turned off. Decreased relaxation provides a means to solidify patterns into a curable material, such as polydimethylsiloxane (PDMS). After the water is evacuated from the fingers, the cured materials then possess hollow channels that can be refilled and emptied, thus creating an artificial circulatory system.

  5. Fingering induced by a solid sphere impact to viscous fluid

    CERN Document Server

    Katsuragi, H

    2014-01-01

    The number of splashed fingers generated by a solid projectile's impact onto a viscous liquid layer is experimentally studied. A steel sphere is dropped onto a viscous liquid pool. Then, a fingering instability occurs around the crater's rim, depending on the experimental conditions such as projectile's inertia and the viscosity of the target liquid. When the impact inertia is not sufficient, any fingering structure cannot be observed. Contrastively, if the impact inertia is too much, the random splashing is induced and the counting of fingers becomes difficult. The clear fingering instability is observable in between these two regimes. The number of fingers $N$ is counted by using high-speed video data. The scaling of $N$ is discussed on the basis of dimensionless numbers. By assuming Rayleigh-Taylor instability, scaling laws for $N$ can be derived using Reynolds number $Re$, Weber number $We$, and Froude number $Fr$. Particularly, the scaling $N=(\\rho_r Fr)^{1/4}We^{1/2}/3^{3/4}$ is obtained for the gravity...

  6. Fingering induced by a solid sphere impact to viscous fluid

    Directory of Open Access Journals (Sweden)

    Katsuragi Hiroaki

    2015-01-01

    Full Text Available The number of splashed fingers generated by a solid projectile’s impact onto a viscous liquid layer is experimentally studied. A steel sphere is dropped onto a viscous liquid pool. Then, a fingering instability occurs around the crater’s rim, depending on the experimental conditions such as projectile’s inertia and the viscosity of the target liquid. When the impact inertia is not sufficient, any fingering structure cannot be observed. Contrastively, if the impact inertia is too much, the random splashing is induced and the counting of fingers becomes difficult. The clear fingering instability is observable in between these two regimes. The number of fingers N is counted by using high-speed video data. The scaling of N is discussed on the basis of dimensionless numbers. By assuming Rayleigh-Taylor instability, scaling laws for N can be derived using Reynolds number Re, Weber number We, and Froude number Fr. Particularly, the scaling N = (ρrFr1/4We1/2/33/4 is obtained for the gravity-dominant cratering regime, where ρr is the density ratio between a projectile and a target. Although the experimental data considerably scatters, the scaling law is consistent with the global trend of the data behavior. Using one of the scaling laws, planetary nano crater’s rim structure is also evaluated.

  7. Enhancement of finger motion range with compliant anthropomorphic joint design.

    Science.gov (United States)

    Çulha, Utku; Iida, Fumiya

    2016-04-01

    Robotic researchers have been greatly inspired by the human hand in the search to design and build adaptive robotic hands. Especially, joints have received a lot of attention upon their role in maintaining the passive compliance that gives the fingers flexibility and extendible motion ranges. Passive compliance, which is the tendency to be employed in motion under the influence of an external force, is the result of the stiffness and the geometrical constraints of the joints that define the direction of the motion. Based on its building elements, human finger joints have multi-directional passive compliance which means that they can move in multiple axis of motion under external force. However, due to their complex anatomy, only simplified biomechanical designs based on physiological analysis are preferred in present day robotics. To imitate the human joints, these designs either use fixed degree of freedom mechanisms which substantially limit the motion axes of compliance, or soft materials that can deform in many directions but hinder the fingers' force exertion capacities. In order to find a solution that lies between these two design approaches, we are using anatomically correct finger bones, elastic ligaments and antagonistic tendons to build anthropomorphic joints with multi-directional passive compliance and strong force exertion capabilities. We use interactions between an index finger and a thumb to show that our joints allow the extension of the range of motion of the fingers up to 245% and gripping size to 63% which can be beneficial for mechanical adaptation in gripping larger objects. PMID:26891473

  8. Biomechanical Analysis of Force Distribution in Human Finger Extensor Mechanisms

    Directory of Open Access Journals (Sweden)

    Dan Hu

    2014-01-01

    Full Text Available The complexities of the function and structure of human fingers have long been recognised. The in vivo forces in the human finger tendon network during different activities are critical information for clinical diagnosis, surgical treatment, prosthetic finger design, and biomimetic hand development. In this study, we propose a novel method for in vivo force estimation for the finger tendon network by combining a three-dimensional motion analysis technique and a novel biomechanical tendon network model. The extensor mechanism of a human index finger is represented by an interconnected tendinous network moving around the phalanx’s dorsum. A novel analytical approach based on the “Principle of Minimum Total Potential Energy” is used to calculate the forces and deformations throughout the tendon network of the extensor mechanism when subjected to an external load and with the finger posture defined by measurement data. The predicted deformations and forces in the tendon network are in broad agreement with the results obtained by previous experimental in vitro studies. The proposed methodology provides a promising tool for investigating the biomechanical function of complex interconnected tendon networks in vivo.

  9. Integrating optical finger motion tracking with surface touch events

    Directory of Open Access Journals (Sweden)

    Jennifer eMacRitchie

    2015-06-01

    Full Text Available This paper presents a method of integrating two contrasting sensor systems for studying human interaction with a mechanical system, using piano performance as the case study. Piano technique requires both precise small-scale motion of fingers on the key surfaces and planned large-scale movement of the hands and arms. Where studies of performance often focus on one of these scales in isolation, this paper investigates the relationship between them. Two sensor systems were installed on an acoustic grand piano: a monocular high-speed camera tracking the position of painted markers on the hands, and capacitive touch sensors attach to the key surfaces which measure the location of finger-key contacts. This paper highlights a method of fusing the data from these systems, including temporal and spatial alignment, segmentation into notes and automatic fingering annotation. Three case studies demonstrate the utility of the multi-sensor data: analysis of finger flexion or extension based on touch and camera marker location, timing analysis of finger-key contact preceding and following key presses, and characterisation of individual finger movements in the transitions between successive key presses. Piano performance is the focus of this paper, but the sensor method could equally apply to other fine motor control scenarios, with applications to human-computer interaction.

  10. Massive failure of TiNbN coating in surface engineered metal-on-metal hip arthroplasty: Retrieval analysis.

    Science.gov (United States)

    Łapaj, Łukasz; Markuszewski, Jacek; Wendland, Justyna; Mróz, Adrian; Wierusz-Kozłowska, Małgorzata

    2016-07-01

    This article presents examination of a failed total hip replacement with surface engineered metal-on-metal (MoM) articulation. The implant was coated with a thin TiNbN film (Physical Vapor Deposition), and at retrieval 53 months after implantation the coating was abraded on weight-bearing part of the head and acetabular component. Scanning electron microscopy of bearing surfaces demonstrated multifocal crack formation, delamination of small film fragments, and formation of aggregates containing nanometer sized wear debris. We also observed coating damage in third body mechanism. Complex failure mechanism of TiNbN coating demonstrated in this study suggests insufficient bonding strength between the coating and substrate alloy and raise concerns regarding the use of such coatings in total hip arthroplasty with MoM bearing. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1043-1049, 2016. PMID:25980456

  11. Automated FingerPrint Background removal: FPB

    Directory of Open Access Journals (Sweden)

    Morgante Michele

    2009-04-01

    Full Text Available Abstract Background The construction of a whole-genome physical map has been an essential component of numerous genome projects initiated since the inception of the Human Genome Project. Its usefulness has been proved for whole-genome shotgun projects as a post-assembly validation and recently it has also been used in the assembly step to constrain on BACs positions. Fingerprinting is usually the method of choice for construction of physical maps. A clone fingerprint is composed of true peaks representing real fragments and background peaks, mainly composed of E. coli genomic DNA, partial digestions, star activity by-products, and machine background. High-throughput fingerprinting leads to the production of thousands of BAC clone fingerprints per day. That is why background peaks removal has become an important issue and needs to be automatized, especially in capillary electrophoresis based fingerprints. Results At the moment, the only tools available for such a task are GenoProfiler and its descendant FPMiner. The large variation in the quality of fingerprints that is usually present in large fingerprinting projects represents a major difficulty in the correct removal of background peaks that has only been partially addressed by the methods so far adopted that all require a long manual optimization of parameters. Thus, we implemented a new data-independent tool, FPB (FingerPrint Background removal, suitable for large scale projects as well as mapping of few clones. Conclusion FPB is freely available at http://www.appliedgenomics.org/tools.php. FPB was used to remove the background from all fingerprints of three grapevine physical map projects. The first project consists of about 50,000 fingerprints, the second one consists of about 70,000 fingerprints, and the third one consists of about 45,000 fingerprints. In all cases a successful assembly was built.

  12. The replacement research reactor

    International Nuclear Information System (INIS)

    The contract for the design, construction and commissioning of the Replacement Research Reactor was signed in July 2000. This was followed by the completion of the detailed design and an application for a construction licence was made in May 2001. This paper will describe the main elements of the design and their relation to the proposed applications of the reactor. The future stages in the project leading to full operation are also described

  13. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A;

    2008-01-01

    BACKGROUND AND AIMS OF THE STUDY: Prompted by anecdotal evidence and observations by surgeons, an investigation was undertaken into the potential differences in implanted aortic valve prosthesis sizes, during aortic valve replacement (AVR) procedures, between northern and southern European countr...... southern European countries. Imbalances in the prevalence of rheumatic heart disease, health resource availability and variations in surgical practice throughout Europe might be possible etiological causes....

  14. Nanotechnology in joint replacement

    OpenAIRE

    Torrecillas, Ramón; J. S. MOYA; Díaz, L. A.; Bartolomé, J. F.; Fernández, Adolfo; Lopez-Esteban, S.

    2009-01-01

    This paper reviews the most relevant achievements and new developments in the field of nanomaterials and their possible impact on the fabrication of a new generation of reliable and longer lasting implants for joint replacement. Special emphasis is given to the role of nanocomposites with different microstructural designs: micro-nano composites, nano-nano composites, macro-micro-nano composites as well as bioinspired hierarchical composite materials. These nanostructured materials have opened...

  15. Renal Replacement Therapy

    OpenAIRE

    Zaccaria Ricci; Stefano Romagnoli; Claudio Ronco

    2016-01-01

    During the last few years, due to medical and surgical evolution, patients with increasingly severe diseases causing multiorgan dysfunction are frequently admitted to intensive care units. Therapeutic options, when organ failure occurs, are frequently nonspecific and mostly directed towards supporting vital function. In these scenarios, the kidneys are almost always involved and, therefore, renal replacement therapies have become a common routine practice in critically ill patients with acute...

  16. Prosthetic replacement in femoral neck fracture in the elderly: Results and review of the literature

    Directory of Open Access Journals (Sweden)

    Marya SKS

    2008-01-01

    Full Text Available Background: Intracapsular fractures of the proximal femur account for a major share of fractures in the elderly. The primary goal of treatment is to return the patient to his or her pre-fracture functional status. There are multiple internal fixation options (screws, dynamic hip screw plate or blade plates and hemi and total hip arthroplasty. Open reduction and internal fixation has been shown to have a high rate of revision surgery due to nonunion and avascular necrosis. Hip replacement arthroplasty (hemi or total is a viable treatment option. Materials and Methods: Eighty-four elderly patients (age> 70 years with a femoral neck fracture were treated over a five-year period (January 2001 to December 2006. Eighty of the 84 patients underwent some form of hip replacement after appropriate medical and anesthetic fitness. Results: We had good results in all the patients in terms of return to pre-fracture level of activity, independent ambulation and satisfaction with the procedure. Patients over the age of 80 years who underwent bipolar hemiarthroplasty all progressed well without any complication. Patients in their seventies underwent some form of total hip replacement and barring one case of deep infection, two cases of deep vein thrombosis and three cases of dislocation (which were managed conservatively, there were no real complications. Conclusion: Hip replacement (hemi or total is a successful procedure for the elderly population over 70 years with femoral neck fractures. Return to pre-morbid level of activity and independent functions occur very swiftly, avoiding the hazards of prolonged incumbency. We have proposed a treatment algorithm following the results of treatment of this fracture in our series. We have also reviewed the different contemporary treatment options used (conservative treatment, cancellous screw fixation, Dynamic Hip Screw (DHS fixation, hemi and total hip replacement used for treatment of an elderly patient with of

  17. Metal on metal hip resurfacing versus uncemented custom total hip replacement - early results

    Directory of Open Access Journals (Sweden)

    Muirhead-Allwood Sarah K

    2010-02-01

    Full Text Available Abstract Introduction There is no current consensus on the most appropriate prosthesis for treating symptomatic osteoarthritis (OA of the hip in young, active patients. Modern metal on metal hip resurfacing arthroplasty (HR has gained popularity as it is theoretically more stable, bone conserving and easier to revise than total hip arthroplasty. Early results of metal on metal resurfacing have been encouraging. We have compared two well matched cohorts of patients with regard to function, pain relief and patient satisfaction. Methods This prospective study compares 2 cohorts of young, active patients treated with hip resurfacing (137 patients, 141 hips and custom uncemented (CADCAM stems (134 patients, 141 hips. All procedures were performed by a single surgeon. Outcome measures included Oxford, WOMAC and Harris hip scores as well as an activity score. Statistical analysis was performed using the unpaired student's t-test. Results One hundred and thirty four and 137 patients were included in the hip replacement and resurfacing groups respectively. The mean age of these patients was 54.6 years. The mean duration of follow up for the hip resurfacing group was 19.2 months compared to 13.4 months for the total hip replacement group. Pre operative oxford, Harris and WOMAC scores in the THA group were 41.1, 46.4 and 50.9 respectively while the post operative scores were 14.8, 95.8 and 5.0. In the HR group, pre- operative scores were 37.0, 54.1 and 45.9 respectively compared to 15.0, 96.8 and 6.1 post operatively. The degree of improvement was similar in both groups. Conclusion There was no significant clinical difference between the patients treated with hip resurfacing and total hip arthroplasty in the short term.

  18. Renal Replacement Therapy.

    Science.gov (United States)

    Ricci, Zaccaria; Romagnoli, Stefano; Ronco, Claudio

    2016-01-01

    During the last few years, due to medical and surgical evolution, patients with increasingly severe diseases causing multiorgan dysfunction are frequently admitted to intensive care units. Therapeutic options, when organ failure occurs, are frequently nonspecific and mostly directed towards supporting vital function. In these scenarios, the kidneys are almost always involved and, therefore, renal replacement therapies have become a common routine practice in critically ill patients with acute kidney injury. Recent technological improvement has led to the production of safe, versatile and efficient dialysis machines. In addition, emerging evidence may allow better individualization of treatment with tailored prescription depending on the patients' clinical picture (e.g. sepsis, fluid overload, pediatric). The aim of the present review is to give a general overview of current practice in renal replacement therapies for critically ill patients. The main clinical aspects, including dose prescription, modality of dialysis delivery, anticoagulation strategies and timing will be addressed. In addition, some technical issues on physical principles governing blood purification, filters characteristics, and vascular access, will be covered. Finally, a section on current standard nomenclature of renal replacement therapy is devoted to clarify the "Tower of Babel" of critical care nephrology. PMID:26918174

  19. Evaluation of finger millet incorporated noodles for nutritive value and glycemic index

    OpenAIRE

    Shukla, Kamini; Srivastava, Sarita

    2011-01-01

    The present study was undertaken to develop finger millet incorporated noodles for diabetic patients. Finger millet variety VL-149 was taken. The finger millet flour and refined wheat flour (RWF) were evaluated for nutrient composition. The finger millet flour (FMF) was blended in various proportions (30 to 50%) in refined wheat flour and used for the preparation of noodles. Control consisted of RWF noodles. Sensory quality and nutrient composition of finger millet noodles was evaluated. The ...

  20. Analysis of Coordinated Motions of Humanoid Robot Fingers Using Interphalangeal Joint Coordination

    OpenAIRE

    Byoung-Ho Kim

    2014-01-01

    In this study, we analyse the coordinated motions of humanoid robot fingers using an interphalangeal joint coordination. For this purpose, four humanoid robot fingers with different sizes have been considered. A biomimetic interphalangeal joint coordination (IJC) formulation based on the grasp configuration of human fingers has been presented for humanoid robot fingers. The usefulness of the specified IJC formulation for human-like finger motion has been verified through comparative demonstra...

  1. Thermal stability improvement of a multiple finger power SiGe heterojunction bipolar transistor under different power dissipations using non-uniform finger spacing

    Institute of Scientific and Technical Information of China (English)

    Chen Liang; Zhang Wan-Rong; Jin Dong-Yue; Shen Pei; Xie Hong-Yun; Ding Chun-Bao; Xiaa Ying; Sun Bo-Tao; Wang Ren-Qing

    2011-01-01

    method of non-uniform finger spacing is proposed to enhance thermal stability of a multiple finger power SiGe hererojunction bipolar transistor under different power dissipations. Temperature distribution on the emitter fingers of a multi-finger SiGe heterojunction bipolar transistor is studied using a numerical electro-thermal model. The results show that the SiGe heterojunction bipolar transistor with non-uniform finger spacing has a small temperature difference between fingers compared with a traditional uniform finger spacing heterojunction bipolar transistor at the same power dissipation. What is most important is that the ability to improve temperature non-uniformity is not weakened as power dissipation increases. So the method of non-uniform finger spacing is very effective in enhancing the thermal stability and the power handing capability of power device. Experimental results verify our conclusious.

  2. Thermal stability improvement of a multiple finger power SiGe heterojunction bipolar transistor under different power dissipations using non-uniform finger spacing

    International Nuclear Information System (INIS)

    A method of non-uniform finger spacing is proposed to enhance thermal stability of a multiple finger power SiGe heterojunction bipolar transistor under different power dissipations. Temperature distribution on the emitter fingers of a multi-finger SiGe heterojunction bipolar transistor is studied using a numerical electro-thermal model. The results show that the SiGe heterojunction bipolar transistor with non-uniform finger spacing has a small temperature difference between fingers compared with a traditional uniform finger spacing heterojunction bipolar transistor at the same power dissipation. What is most important is that the ability to improve temperature non-uniformity is not weakened as power dissipation increases. So the method of non-uniform finger spacing is very effective in enhancing the thermal stability and the power handing capability of power device. Experimental results verify our conclusions. (interdisciplinary physics and related areas of science and technology)

  3. From convection rolls to finger convection in double-diffusive turbulence

    Science.gov (United States)

    Yang, Yantao; Verzicco, Roberto; Lohse, Detlef

    2015-11-01

    The double diffusive convection (DDC), where the fluid density depends on two scalar components with very different molecular diffusivities, is frequently encountered in oceanography, astrophysics, and electrochemistry. In this talk we report a systematic study of vertically bounded DDC for various control parameters. The flow is driven by an unstable salinity difference between two plates and stabilized by a temperature difference. As the relative strength of temperature difference becomes stronger, the flow transits from a state with large-scale convection rolls, which is similar to the Rayleigh-Bénard (RB) flow, to a state with well-organised salt fingers. When the temperature difference increases further, the flow breaks down to a purely conductive state. During this transit the velocity decreases monotonically. Counterintuitively, the salinity transfer can be enhanced when a stabilising temperature field is applied to the system. This happens when convection rolls are replaced by salt fingers. In addition, we show that the Grossmann-Lohse theory originally developed for RB flow can be directly applied to the current problem and accurately predicts the salinity transfer rate for a wide range of control parameters. Supported by Stichting FOM and the National Computing Facilities (NCF), both sponsored by NWO. The simulations were conducted on the Dutch supercomputer Cartesius at SURFsara.

  4. DESIGN AND IMPLEMENTATION OF ELCTRONIC VOTING SYSTEM USING FINGER PRINT AND ZIG-BEE

    Directory of Open Access Journals (Sweden)

    KRISHNA CHAITANYA

    2014-08-01

    Full Text Available Now-a-days voting process is exercised by using EVM (Electronic voting Machine. The very common problem, rigging which can be faced in every electoral procedure. One candidate can cast the vote of all members or of some other members in electoral list illegally. This results in the loss of votes for other contestants. There is some scope of work in EVM, because there is no way of identification by EVM whether the user is authentic or not. To replace this system, a novel approach is introduced i.e.., EVM added with a finger print verifier. By this way, a single person can vote only once and also bogus voting is eliminated since it is impossible to replicate the finger print of a person. In this paper, Zig-Bee technology is used for wireless sensor data communication. The results will be updated in Master device i.e. (personal computer through Zig-Bee.The Master device is operated by election officer.

  5. Radial Head Arthroplasty with A Modular Prosthesis – Initial Experience

    Directory of Open Access Journals (Sweden)

    Petrov V.

    2016-03-01

    Full Text Available The Mason type III and IV radial head fractures are severe injuries that lead to decreased range of motion, alteration in the kinematics, the load transfer and the stability of the elbow. They are often in conjunction with ligament injuries, anterior or posterior joint dislocations and fractures of the coronoid process, the humeral capitulum and the olecranon. The resection of the head leads to elbow instability, late complications and arthrosis of the elbow. The open reduction and internal fixation (ORIF in Mason type III and IV fractures is not able to restore and sustain the anatomical structure and function of the radiocapitellar joint. That is why these fractures require arthroplasty. The best results are reported with the use of metal bipolar prosthetics. We present our initial experience with radial head arthroplasty on three patients with mean follow up 18 months and a review of the English literature.

  6. Prediction of Wear in Crosslinked Polyethylene Unicompartmental Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Jonathan Netter

    2015-05-01

    Full Text Available Wear-related complications remain a major issue after unicompartmental arthroplasty. We used a computational model to predict knee wear generated in vitro under diverse conditions. Inverse finite element analysis of 2 different total knee arthroplasty designs was used to determine wear factors of standard and highly crosslinked polyethylene by matching predicted wear rates to measured wear rates. The computed wear factor was used to predict wear in unicompartmental components. The articular surface design and kinematic conditions of the unicompartmental and tricompartmental designs were different. Predicted wear rate (1.77 mg/million cycles was very close to experimental wear rate (1.84 mg/million cycles after testing in an AMTI knee wear simulator. Finite element analysis can predict experimental wear and may reduce the cost and time of preclinical testing.

  7. Modification of the total first metatarsophalangeal joint implant arthroplasty.

    Science.gov (United States)

    Corrigan, G; Kanat, I O

    1989-01-01

    The Swanson Silastic HP 100 Flexible Hinge Toe Implant (Dow Corning Wright, Arlington Tennessee) displays superior tensile, elongation and tear propagation strength in comparison to other silicone implant materials. It is, however, subject to many factors which may shorten its life-span. One reason for such failure has been attributed to the irregular contour of bone ends created after metatarsophalangeal joint arthroplasty, resulting in abrasion shards and shearing fractures of the implant stems and hinge. Titanium grommets were developed to alleviate this factor. This case report demonstrates a complication subsequent to total first metatarsophalangeal joint implant arthroplasty and the effectiveness of the Swanson Flexible Hinge Toe Joint Grommet. (Dow Corning Wright, Arlington, Tennessee). PMID:2794361

  8. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... where I’ll start my incision, and again, running about two centimeters or two finger breadths lateral ... pull. And what we do is a simple running suture. What’s in your big-ten cocktail? And ...

  9. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... When I dislocate a smaller head like a 32 or a 28 head, I am going to keep my finger over the top of the head to prevent it from jumping over the pelvis. There’s been reports with two incisions in particular, when you do ...

  10. PRIMARY CEMENTLESS TOTAL HIP ARTHROPLASTY IN ANKYLOSING SPONDYLITIS

    OpenAIRE

    Nageshwara Rao; Ravikumar

    2015-01-01

    INTRODUCTION Ankylosing Spondylitis (AS), family of Spondyloarthritides (SpAs), is a chronic inflammatory disease affecting the axial skeleton, the entheses and occasionally the peripheral joints. The shoulders and hips are considered axial joints and involvement occurs in up to 50% of patients and is more common than involvement of the more distal joints. Aim of our study is to evaluate outcome of Cementless Total Hip Arthroplasty (THA) in ankylosing spondylitis. MAT...

  11. Can pelvic tilting be ignored in total hip arthroplasty?

    Directory of Open Access Journals (Sweden)

    Won Yong Shon

    2014-01-01

    CONCLUSION: The sagittal position of pelvis is a key factor in impingement and dislocation after total hip arthroplasty. Pelvic tilting affects the position of acetabular component in the sagittal plane of the body as compared with its anatomic position in the pelvis. We suggest a preoperative lateral view of spine-pelvis, in upright and supine position for evaluation of a corrective adaptation of the acetabular cup accordingly with pelvic balance.

  12. Tibial stress fracture after computer-navigated total knee arthroplasty

    OpenAIRE

    Massai, F.; Conteduca, F.; Vadalà, A.; Iorio, R.; Basiglini, L.; Ferretti, A.

    2010-01-01

    A correct alignment of the tibial and femoral component is one of the most important factors determining favourable long-term results of a total knee arthroplasty (TKA). The accuracy provided by the use of the computer navigation systems has been widely described in the literature so that their use has become increasingly popular in recent years; however, unpredictable complications, such as displaced or stress femoral or tibial fractures, have been reported to occur a few weeks after the ope...

  13. Short-Term Results of Medial Unicondylar Knee Arthroplasty

    OpenAIRE

    Murat Yılmaz; Samed Ordu; Erhan Bayram; İbrahim Sungur; Ercan Çetinus

    2014-01-01

    Aim: This study aimed to determine the short-term clinical and radiologic results of medial unicondylar knee arthroplasty (UKA). Methods: We retrospectively evaluated hospital records of eight patients who have undergone Oxford phase-3 medial UKA between 2011 and 2013. We included seven patients (two males and five females) in the study. The mean age of the patients was 63 years and the mean follow-up period was 17 months. The patients underwent UKA with the Oxford phase 3 cemented mobile ...

  14. Total hip arthroplasty in very young bone marrow transplant patients.

    Science.gov (United States)

    Ledford, Cameron K; Vap, Alexander R; Bolognesi, Michael P; Wellman, Samuel S

    2015-01-01

    Concerns remain about total hip arthroplasty (THA) performed in very young patients, especially those with complex medical history such as allogeneic bone marrow transplantation (ABMT). This study retrospectively reviews the perioperative courses and functional outcomes of ABMT patients history of severe hematopoietic conditions requiring ABMT, these very young patients do appear to have improved pain and function following primary THA with short-term follow-up. PMID:25988690

  15. Vibroacoustography for the assessment of total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Hermes A.S. Kamimura

    2013-04-01

    Full Text Available OBJECTIVES: This paper proposes imaging with 3-dimensional vibroacoustography for postoperatively assessing the uncovered cup area after total hip arthroplasty as a quantitative criterion to evaluate implant fixation. METHODS: A phantom with a bone-like structure covered by a tissue-mimicking material was used to simulate a total hip arthroplasty case. Vibroacoustography images of the uncovered cup region were generated using a two-element confocal ultrasound transducer and a hydrophone inside a water tank. Topological correction based on the geometry of the implant was performed to generate a 3-dimensional representation of the vibroacoustography image and to accurately evaluate the surface. The 3-dimensional area obtained by the vibroacoustography approach was compared to the area evaluated by a 3-dimensional motion capture system. RESULTS: The vibroacoustography technique provided high-resolution, high-contrast, and speckle-free images with less sensitivity to the beam incidence. Using a 3-dimensional-topology correction of the image, we accurately estimated the uncovered area of the implant with a relative error of 8.1% in comparison with the motion capture system measurements. CONCLUSION: Measurement of the cup coverage after total hip arthroplasty has not been well established; however, the covered surface area of the acetabular component is one of the most important prognostic factors. The preliminary results of this study show that vibroacoustography is a 3-dimensional approach that can be used to postoperatively evaluate total hip arthroplasty. The favorable results also provide an impetus for exploring vibroacoustography in other bone or implant surface imaging applications.

  16. Patellofemoral Arthroplasty: A Systematic Review of the Literature

    OpenAIRE

    Tarassoli, Payam; Punwar, Shahid; Khan, Wasim; Johnstone, David

    2012-01-01

    Identification and management of patients with isolated patellofemoral osteoarthritis are challenging. Many of these patients present at a young age and it is important to distinguish degenerative change in the patellofemoral articulation from the other various causes of anterior knee pain. Once the diagnosis of isolated patellofemoral arthrosis has been made non-operative and conservative surgical techniques should be exhausted fully before prosthetic arthroplasty is considered. This review ...

  17. Do pessimists report worse outcomes after total hip arthroplasty?

    OpenAIRE

    Singh, Jasvinder A; Colligan, Robert C.; O’Byrne, Megan M.; David G Lewallen

    2016-01-01

    Background Seligman’s theory of causal attribution predicts that patients with a pessimistic explanatory style will have less favorable health outcomes. We investigated this hypothesis using self-reported hip pain and hip function 2- years after total hip arthroplasty (THA). Methods Most THA patients had completed the Minnesota Multiphasic Personality Inventory (MMPI) during their usual clinical care long before THA (median, 14.7 to 16.6 years). Scores from the MMPI Optimism-Pessimism (PSM) s...

  18. Patient-reported outcome measures after total knee arthroplasty

    OpenAIRE

    Ramkumar, P. N.; Harris, J D; Noble, P. C.

    2015-01-01

    Objectives A lack of connection between surgeons and patients in evaluating the outcome of total knee arthroplasty (TKA) has led to the search for the ideal patient-reported outcome measure (PROM) to evaluate these procedures. We hypothesised that the desired psychometric properties of the ideal outcome tool have not been uniformly addressed in studies describing TKA PROMS. Methods A systematic review was conducted investigating one or more facets of patient-reported scores for measuring prim...

  19. Spontaneous Knee Ankylosis through Heterotopic Ossification after Total Knee Arthroplasty

    OpenAIRE

    Samuel Boulezaz; Emmanuel Gibon; Philippe Loriaut; Laurent Casabianca; Romain Rousseau; Benjamin Dallaudiere; Hugues Pascal-Moussellard

    2016-01-01

    This paper reports on a case of total ankylosis of the knee after a cruciate-sacrificing cemented total knee arthroplasty (TKA). An 82-year-old female patient previously underwent primary TKA for osteoarthritis twenty years ago in our institution. She had recovered uneventfully and returned to her regular activities. There was no history of postsurgical trauma; however, she progressively lost knee range of motion. Radiographs revealed severe bridging heterotopic ossification.

  20. Management of failed metal-on-metal total hip arthroplasty

    OpenAIRE

    Griffin, Justin W.; D’Apuzzo, Michele; Browne, James A.

    2012-01-01

    The theoretical advantages of metal-on-metal (MOM) bearing couples in total hip arthroplasty (THA) have been recently balanced by concerns regarding adverse local and systemic effects. Higher than anticipated early revision rates have been reported by several joint registries. Failed MOM hips present with a spectrum of symptoms and findings and traditional methods of failure must be considered in addition to the failure modes that appear to be unique to the MOM bearing couple. Metal hypersens...

  1. Spontaneous Knee Ankylosis through Heterotopic Ossification after Total Knee Arthroplasty

    Science.gov (United States)

    Boulezaz, Samuel; Gibon, Emmanuel; Loriaut, Philippe; Casabianca, Laurent; Rousseau, Romain; Dallaudiere, Benjamin; Pascal-Moussellard, Hugues

    2016-01-01

    This paper reports on a case of total ankylosis of the knee after a cruciate-sacrificing cemented total knee arthroplasty (TKA). An 82-year-old female patient previously underwent primary TKA for osteoarthritis twenty years ago in our institution. She had recovered uneventfully and returned to her regular activities. There was no history of postsurgical trauma; however, she progressively lost knee range of motion. Radiographs revealed severe bridging heterotopic ossification. PMID:27119034

  2. Spontaneous arteriorrhexis in affected lower limb following total knee arthroplasty

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ya-feng; JIANG Qing; WANG Jun-fei

    2008-01-01

    @@ Total knee arthroplasty ( TKA) is now a standard treatment for serious osteoarthritis all over the world. Although it is a standard treatment, it has many complications, among which deep vein thrombosis ( DVT) is the exclusive blood vessel complication that has been reported.1,2 However, we found a new blood vessel complication of TKA in this study, which is spontaneous arteriorrhexis in the affected lower limb.

  3. Applications of porous tantalum in total hip arthroplasty.

    Science.gov (United States)

    Levine, Brett; Della Valle, Craig J; Jacobs, Joshua J

    2006-11-01

    Porous tantalum is an alternative metal for total joint arthroplasty components that offers several unique properties. Its high volumetric porosity (70% to 80%), low modulus of elasticity (3 MPa), and high frictional characteristics make it conducive to biologic fixation. Tantalum has excellent biocompatibility and is safe to use in vivo. The low modulus of elasticity allows for more physiologic load transfer and relative preservation of bone stock. Because of its bioactive nature and ingrowth properties, tantalum is used in primary as well as revision total hip arthroplasty components, with good to excellent early clinical results. In revision arthroplasty, standard and custom augments may serve as a structural bone graft substitute. Formation of a bone-like apatite coating in vivo affords strong fibrous ingrowth properties and allows for substantial soft-tissue attachment, indicating potential for use in cases requiring reattachment of muscles and tendons to a prosthesis. Development of modular components and femoral stems also is being evaluated. The initial clinical data and basic science studies support further investigation of porous tantalum as an alternative to traditional implant materials. PMID:17077337

  4. [Recovery from total knee arthroplasty through continuous passive motion].

    Science.gov (United States)

    Sánchez Mayo, B; Rodríguez-Mansilla, J; González Sánchez, B

    2015-01-01

    The purpose of this study was to know the effects of continuous passive mobilization in patients who underwent total knee arthroplasty. A search strategy was developed to retrieve all clinical trials, written in English and/or Spanish, published in the electronic search databases PubMed, Cochrane Library Plus, Dialnet, CSIC and PEDro. The inclusion criteria were: clinical trials published from January 2000 until November 2014 in English or Spanish. Out of 537 clinical trials that were potentially relevant, a total of 12 were included in this review. The evaluation of 1,153 patients shows that there is no significant difference in improving the range of the joint, pain, balance, motion, healing and hospital stay using continuous passive mobilization against the regular physiotherapy treatment for total knee arthroplasty. The application of continuous passive mobilization in the long-term does not provide any benefit in terms of the breadth of the range of the joint, pain and improvement of standing and motion in comparison with conventional postoperative physiotherapy treatment in total knee arthroplasty. In the short term an improvement is obtained in the range of joint motion in knee flexion. PMID:26486536

  5. Zinc-finger antiviral protein inhibits XMRV infection.

    Directory of Open Access Journals (Sweden)

    Xinlu Wang

    Full Text Available BACKGROUND: The zinc-finger antiviral protein (ZAP is a host factor that specifically inhibits the replication of certain viruses, including Moloney murine leukemia virus (MoMLV, HIV-1, and certain alphaviruses and filoviruses. ZAP binds to specific viral mRNAs and recruits cellular mRNA degradation machinery to degrade the target RNA. The common features of ZAP-responsive RNA sequences remain elusive and thus whether a virus is susceptible to ZAP can only be determined experimentally. Xenotropic murine leukemia virus-related virus (XMRV is a recently identified γ-retrovirus that was originally thought to be involved in prostate cancer and chronic fatigue syndrome but recently proved to be a laboratory artefact. Nonetheless, XMRV as a new retrovirus has been extensively studied. Since XMRV and MoMLV share only 67.9% sequence identity in the 3'UTRs, which is the target sequence of ZAP in MoMLV, whether XMRV is susceptible to ZAP remains to be determined. FINDINGS: We constructed an XMRV-luc vector, in which the coding sequences of Gag-Pol and part of Env were replaced with luciferase-coding sequence. Overexpression of ZAP potently inhibited the expression of XMRV-luc in a ZAP expression-level-dependent manner, while downregulation of endogenous ZAP rendered cells more sensitive to infection. Furthermore, ZAP inhibited the spreading of replication-competent XMRV. Consistent with the previously reported mechanisms by which ZAP inhibits viral infection, ZAP significantly inhibited the accumulation of XMRV-luc mRNA in the cytoplasm. The ZAP-responsive element in XMRV mRNA was mapped to the 3'UTR. CONCLUSIONS: ZAP inhibits XMRV replication by preventing the accumulation of viral mRNA in the cytoplasm. Documentation of ZAP inhibiting XMRV helps to broaden the spectrum of ZAP's antiviral activity. Comparison of the target sequences of ZAP in XMRV and MoMLV helps to better understand the features of ZAP-responsive elements.

  6. SPECT/CT in patients with painful knee arthroplasty - what is the evidence?

    Energy Technology Data Exchange (ETDEWEB)

    Hirschmann, Michael T. [Kantonsspital Baselland-Bruderholz, Department of Orthopaedic Surgery and Traumatology, Bruderholz (Switzerland); Henckel, Johann [Imperial College London, London (United Kingdom); Rasch, Helmut [Kantonsspital Baselland-Bruderholz, Institute for Radiology and Nuclear Medicine, Bruderholz (Switzerland)

    2013-09-15

    SPECT/CT is increasingly recognized as a promising imaging modality for the investigation of patients with a painful knee after knee arthroplasty. In this review article, we give an overview of the clinical value and current and future applications of SPECT/CT for patients with knee pain following joint arthroplasty. A detailed evidence-based literature review is performed and presented. (orig.)

  7. Small increase of actual physical activity 6 months after total hip or knee arthroplasty

    NARCIS (Netherlands)

    I.B. de Groot (Ingrid); J.B.J. Bussmann (Hans); H.J. Stam (Henk); J.A.N. Verhaar (Jan)

    2008-01-01

    textabstractLimitation in daily physical activity is one of the reasons for total hip arthroplasty (THA) or total knee arthroplasty (TKA). However, studies of the effects of THA or TKA generally do not determine actual daily activity as part of physical functioning. We determined the effect of THA o

  8. Minimally Invasive Total Hip and Knee Arthroplasty-Implications for the Elderly Patient

    NARCIS (Netherlands)

    Reininga, Inge H. F.; Stevens, Martin; Wagenmakers, Robert; Bulstra, Sjoerd K.; van den Akker-Scheek, Inge

    2012-01-01

    Total hip arthroplasty and total knee arthroplasty have proven to be effective surgical procedures for the treatment of hip and knee osteoarthritis. In recent decades, there have been considerable efforts to improve the component designs, modes of fixation, and surgical techniques. Minimally invasiv

  9. Loss of knee-extension strength is related to knee swelling after total knee arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten T; Bencke, Jesper;

    2010-01-01

    To examine whether changes in knee-extension strength and functional performance are related to knee swelling after total knee arthroplasty (TKA).......To examine whether changes in knee-extension strength and functional performance are related to knee swelling after total knee arthroplasty (TKA)....

  10. Care principles at four fast-track arthroplasty departments in Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Solgaard, Søren; Hansen, Torben Bæk;

    2010-01-01

    The goal of this study was to describe the logistic and clinical set-up at four Danish arthroplasty departments offering fast-track surgery.......The goal of this study was to describe the logistic and clinical set-up at four Danish arthroplasty departments offering fast-track surgery....

  11. Revision total knee arthroplasty with the use of trabecular metal cones

    DEFF Research Database (Denmark)

    Jensen, Claus L; Petersen, Michael Mygind; Schrøder, Henrik; Flivik, Gunnar; Lund, Bjarne

    2012-01-01

    "Trabecular Metal Cone" (TM Cone) (Zimmer, Inc, Warsaw, Ind) for reconstruction of bone loss in the proximal tibia during revision total knee arthroplasty is now optional. Forty patients were randomized to receive revision total knee arthroplasty with or without TM Cone (No TM Cone). The Anderson...

  12. ESOPHAGEAL REPLACEMENT IN CHILDREN

    Directory of Open Access Journals (Sweden)

    G. Giannotti

    2012-01-01

    Full Text Available Introduction: esophageal replacement in childhood, is indicated for intractable stenosis and long-gap atresia. When it is impossible to preserve the native esophagus we must create an appropriate conduit that should allow physiological oral feeding. Patients and Methods: we present two cases. The first patient, born with long gap esophageal atresia (AE, was submitted to ligation of fistula, gastrostomy and esophagostomy. When he was 1 years old came to our observation with two derivations. The radiological examination with contrast confirmed the large gap between the two oesophageal stumps. We decided to refer the patient to esophageal substitution with isoperistaltic jejunum through the posterior mediastinum. The second patient was born with AE type III and he was submitted to ligation of fistula, primary anastomosis, and 4 additional interventions of closure of recurrent fistula, esophageal resection and anti-reflux surgery. He came to our observation when he was 6 years old. The radiography showed esophageal dysmotility and dislocation of the stomach in the chest. We decided to subject the patient to esophageal replacement with stomach in toto. Results: Both patients had a good post-operative course. They began food orally in the first case in 18th day and in the second case in 7th. At follow-up after 1 year the children ate regularly, they don’t show respiratory symptoms or gastro-oesophageal reflux and they have a good growth. Conclusions: Esophageal replacement is a complex surgical procedure, which provides various options. Only a careful preoperative evaluation allows us a choice of organ to be used as esophageal substitute. The colon is the most widely used. There are other surgical options that may offer, in skilled hands, the same guarantees. Both our cases have a good long term follow-up with regular diet and weight-height growth. Our experience confirms the validity of the 2 techniques, which include preferably the use of

  13. ZFNGenome: A comprehensive resource for locating zinc finger nuclease target sites in model organisms

    Directory of Open Access Journals (Sweden)

    Voytas Daniel F

    2011-01-01

    Full Text Available Abstract Background Zinc Finger Nucleases (ZFNs have tremendous potential as tools to facilitate genomic modifications, such as precise gene knockouts or gene replacements by homologous recombination. ZFNs can be used to advance both basic research and clinical applications, including gene therapy. Recently, the ability to engineer ZFNs that target any desired genomic DNA sequence with high fidelity has improved significantly with the introduction of rapid, robust, and publicly available techniques for ZFN design such as the Oligomerized Pool ENgineering (OPEN method. The motivation for this study is to make resources for genome modifications using OPEN-generated ZFNs more accessible to researchers by creating a user-friendly interface that identifies and provides quality scores for all potential ZFN target sites in the complete genomes of several model organisms. Description ZFNGenome is a GBrowse-based tool for identifying and visualizing potential target sites for OPEN-generated ZFNs. ZFNGenome currently includes a total of more than 11.6 million potential ZFN target sites, mapped within the fully sequenced genomes of seven model organisms; S. cerevisiae, C. reinhardtii, A. thaliana, D. melanogaster, D. rerio, C. elegans, and H. sapiens and can be visualized within the flexible GBrowse environment. Additional model organisms will be included in future updates. ZFNGenome provides information about each potential ZFN target site, including its chromosomal location and position relative to transcription initiation site(s. Users can query ZFNGenome using several different criteria (e.g., gene ID, transcript ID, target site sequence. Tracks in ZFNGenome also provide "uniqueness" and ZiFOpT (Zinc Finger OPEN Targeter "confidence" scores that estimate the likelihood that a chosen ZFN target site will function in vivo. ZFNGenome is dynamically linked to ZiFDB, allowing users access to all available information about zinc finger reagents, such as the

  14. Immediate total tooth replacement.

    Science.gov (United States)

    Garber, D A; Salama, M A; Salama, H

    2001-03-01

    Successful implant placement at the time of extraction has been documented. Implant placement at the time of extraction was initially performed as a two-stage procedure often with barrier membranes and sophisticated second-stage surgical uncoverings. The authors describe the next generation of this technique, including atraumatic tooth removal with simultaneous root form, implant placement, and temporization at one appointment. This technique of "Immediate Total Tooth Replacement" allows for the maintenance of the bony housing and soft-tissue form that existed before extraction, while at the same time establishing a root form anchor in the bone for an esthetic restoration. PMID:11913258

  15. Magic Ring: A Finger-Worn Device for Multiple Appliances Control Using Static Finger Gestures

    Directory of Open Access Journals (Sweden)

    Tongjun Huang

    2012-05-01

    Full Text Available An ultimate goal for Ubiquitous Computing is to enable people to interact with the surrounding electrical devices using their habitual body gestures as they communicate with each other. The feasibility of such an idea is demonstrated through a wearable gestural device named Magic Ring (MR, which is an original compact wireless sensing mote in a ring shape that can recognize various finger gestures. A scenario of wireless multiple appliances control is selected as a case study to evaluate the usability of such a gestural interface. Experiments comparing the MR and a Remote Controller (RC were performed to evaluate the usability. From the results, only with 10 minutes practice, the proposed paradigm of gestural-based control can achieve a performance of completing about six tasks per minute, which is in the same level of the RC-based method.

  16. Quadriceps Tendon Rupture and Contralateral Patella Tendon Avulsion Post Primary Bilateral Total Knee Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Gaurav Sharma

    2016-07-01

    Full Text Available Background: Extensor mechanism failure secondary to knee replacement could be due to tibial tubercle avulsion, Patellar tendon rupture, patellar fracture or quadriceps tendon rupture. An incidence of Patella tendon rupture of 0.17% and Quadriceps tendon rupture of around 0.1% has been reported after Total knee arthroplasty. These are considered a devastating complication that substantially affects the clinical results and are challenging situations to treat with surgery being the mainstay of the treatment. Case Description: We report here an interesting case of a patellar tendon rupture of one knee and Quadriceps tendon rupture of the contralateral knee following simultaneous bilateral knee replacement in a case of inflammatory arthritis patient. End to end repair for Quadriceps tear and augmentation with Autologous Hamstring tendon graft was done for Patella tendon rupture. OUTCOME: Patient was followed up for a period of 1 year and there was no Extension lag with a flexion of 100 degrees in both the knees. DISCUSSION: The key learning points and important aspects of diagnosing these injuries early and the management techniques are described in this unique case of bilateral extensor mechanism disruption following knee replacements.

  17. Evaluation of electron beam irradiation for disinfection of turmeric fingers

    International Nuclear Information System (INIS)

    Turmeric finger as one of the most popular spices has been widely used for food manufacturing. However, it has also been a major cause of bacterial infestation of food materials especially in curry, ham and sausage manufacturing. In this study decontamination of bacteria in turmeric finger by electron beam irradiation was evaluated by comparing with several other decontamination methods: i.e., boiling, microwave irradiation, treatment by twin screw extruder and gamma-ray irradiation. By estimation of colony counting on nutrient agar plate, turmeric finger without any treatment gave total viable cell at 108/g. Turmeric finger which was irradiated by electron beam at 10kGy dose dramatically reduced thermotolerant cell population below self restriction level (<1000/g), which has been required by food hygiene law. The same level of sterilization effect was obtained only by gamma-ray irradiation at 10kGy and 20kGy. On the other hand, although treatment through twin screw extruder slightly reduced bacterial numbers, neither boiling nor microwave irradiation gave sufficient decontamination effect on turmeric fingers

  18. Evaluation of electron beam irradiation for disinfection of turmeric fingers

    International Nuclear Information System (INIS)

    Turmeric finger as one of the most popular spices has been widely used for food manufacturing. However, it has also been a major cause of bacterial infestation of food materials especially in curry, ham and sausage manufacturing. In this study decontamination of bacteria in turmeric finger by electron beam irradiation was evaluated by comparing with several other decontamination methods: i.e., boiling, microwave irradiation, treatment by twin screw extruder and gamma-ray irradiation. By estimation of colony counting on nutrient agar plate, turmeric finger without any treatment gave total viable cell at 108/g. Turmeric finger which was irradiated by electron beam at 10 kGy dose dramatically reduced thermotolerant cell population below self restriction level (<1000/g), which has been required by food hygiene law. The same level of sterilization effect was obtained only by gamma-ray irradiation at 10 kGy and 20 kGy. On the other hand, although treatment through twin screw extruder slightly reduced bacterial numbers, neither boiling nor microwave irradiation gave sufficient decontamination effect on turmeric fingers. (author)

  19. The biometric recognition on contactless multi-spectrum finger images

    Science.gov (United States)

    Kang, Wenxiong; Chen, Xiaopeng; Wu, Qiuxia

    2015-01-01

    This paper presents a novel multimodal biometric system based on contactless multi-spectrum finger images, which aims to deal with the limitations of unimodal biometrics. The chief merits of the system are the richness of the permissible texture and the ease of data access. We constructed a multi-spectrum instrument to simultaneously acquire three different types of biometrics from a finger: contactless fingerprint, finger vein, and knuckleprint. On the basis of the samples with these characteristics, a moderate database was built for the evaluation of our system. Considering the real-time requirements and the respective characteristics of the three biometrics, the block local binary patterns algorithm was used to extract features and match for the fingerprints and finger veins, while the Oriented FAST and Rotated BRIEF algorithm was applied for knuckleprints. Finally, score-level fusion was performed on the matching results from the aforementioned three types of biometrics. The experiments showed that our proposed multimodal biometric recognition system achieves an equal error rate of 0.109%, which is 88.9%, 94.6%, and 89.7% lower than the individual fingerprint, knuckleprint, and finger vein recognitions, respectively. Nevertheless, our proposed system also satisfies the real-time requirements of the applications.

  20. Evaluation of electron beam irradiation for disinfection of turmeric fingers

    Energy Technology Data Exchange (ETDEWEB)

    Yasumoto, Kyoden; Fujino, Masayuki; Supriyadi (Kyoto Univ., Uji (Japan). Research Inst. for Food Science); Suzuki, Tetsuya; Hayashi, Toru

    1991-08-01

    Turmeric finger as one of the most popular spices has been widely used for food manufacturing. However, it has also been a major cause of bacterial infestation of food materials especially in curry, ham and sausage manufacturing. In this study decontamination of bacteria in turmeric finger by electron beam irradiation was evaluated by comparing with several other decontamination methods: i.e., boiling, microwave irradiation, treatment by twin screw extruder and gamma-ray irradiation. By estimation of colony counting on nutrient agar plate, turmeric finger without any treatment gave total viable cell at 10{sup 8}/g. Turmeric finger which was irradiated by electron beam at 10 kGy dose dramatically reduced thermotolerant cell population below self restriction level (<1000/g), which has been required by food hygiene law. The same level of sterilization effect was obtained only by gamma-ray irradiation at 10 kGy and 20 kGy. On the other hand, although treatment through twin screw extruder slightly reduced bacterial numbers, neither boiling nor microwave irradiation gave sufficient decontamination effect on turmeric fingers. (author).

  1. Zinc Finger Nuclease-Mediated Gene Targeting in Plants

    International Nuclear Information System (INIS)

    Zinc finger nucleases were used to facilitate homology driven repair and site-specific transgene integration in transgenic tobacco cell cultures. A target DNA sequence containing a non-functional, partial 3' PAT gene sequence flanked by zinc finger binding sites was stably integrated into BY2 suspension cultures using Agrobacterium-mediated transformation. A transgenic event containing a single integrated copy of the target sequence was used for gene targeting through co-transformation with two different Agrobacterium strains containing: i) donor DNA sequences comprising the 5' partial DNA fragment necessary to correct the non-functional PAT gene flanked by sequences homologous to the pre-integrated target DNA and ii) DNA that encoded a zinc finger nuclease that specifically recognized binding sites within the pre-integrated target. Two gene targeting strategies differing with respect to the distance between the zinc finger binding site and the homologous sequences were used. Gene targeting was demonstrated for both strategies as evidenced by the re-constitution of a functional PAT gene and was confirmed via molecular and biochemical analyses. Sequencing of recombined DNA confirmed that PAT gene reconstitution resulted from homology-driven repair at the zinc finger nuclease cleavage site. However, imperfect recombination resulting from non-homologous processes was also observed. (author)

  2. Hybrid-Actuated Finger Prosthesis with Tactile Sensing

    Directory of Open Access Journals (Sweden)

    Cheng Yee Low

    2013-10-01

    Full Text Available Finger prostheses are devices developed to emulate the functionality of natural human fingers. On top of their aesthetic appearance in terms of shape, size and colour, such biomimetic devices require a high level of dexterity. They must be capable of gripping an object, and even manipulating it in the hand. This paper presents a biomimetic robotic finger actuated by a hybrid mechanism and integrated with a tactile sensor. The hybrid actuation mechanism comprises a DC micromotor and a Shape Memory Alloy (SMA wire. A customized test rig has been developed to measure the force and stroke produced by the SMA wire. In parallel with the actuator development, experimental investigations have been conducted on Quantum Tunnelling Composite (QTC and Pressure Conductive Rubber (PCR towards the development of a tactile sensor for the finger. The viability of using these materials for tactile sensing has been determined. Such a hybrid actuation approach aided with tactile sensing capability enables a finger design as an integral part of a prosthetic hand for applications up to the transradial amputation level.

  3. Conversion of ankle autofusion to total ankle replacement using the Salto XT revision prosthesis.

    Science.gov (United States)

    Williamson, Emilie R C; Demetracopoulos, Constantine A; Ellis, Scott J

    2016-09-01

    Few reports in the literature have described the conversion of a surgically fused ankle to a total ankle replacement. The takedown of an autofusion and conversion to a prosthesis has not been described. We report the case of a patient with severe rheumatoid arthritis with an ankle autofusion fixed in equinus and severe talonavicular arthritis that was converted to ankle replacement using the Salto XT revision system. We describe the reasons why the decision was made to perform total ankle arthroplasty while concomitantly fusing the talonavicular joint, and discuss the rationale of the various surgical treatment options considered. We describe the clinical and radiographic outcomes achieved in this case. At 12 months post-operatively the patient reported significant reduction of pain, increased FAOS scores and had increased ankle range of motion. PMID:27502236

  4. Prediction of contact forces of underactuated finger by adaptive neuro fuzzy approach

    Science.gov (United States)

    Petković, Dalibor; Shamshirband, Shahaboddin; Abbasi, Almas; Kiani, Kourosh; Al-Shammari, Eiman Tamah

    2015-12-01

    To obtain adaptive finger passive underactuation can be used. Underactuation principle can be used to adapt shapes of the fingers for grasping objects. The fingers with underactuation do not require control algorithm. In this study a kinetostatic model of the underactuated finger mechanism was analyzed. The underactuation is achieved by adding the compliance in every finger joint. Since the contact forces of the finger depend on contact position of the finger and object, it is suitable to make a prediction model for the contact forces in function of contact positions of the finger and grasping objects. In this study prediction of the contact forces was established by a soft computing approach. Adaptive neuro-fuzzy inference system (ANFIS) was applied as the soft computing method to perform the prediction of the finger contact forces.

  5. REPLACEMENT OF FRENCH CARDS

    CERN Multimedia

    HR/SOC

    2001-01-01

    The French Ministry of Foreign Affairs has informed the Organization that it is shortly to replace all diplomatic cards, special cards and employment permits ('attestations de fonctions') now held by members of the personnel and their families. Between 2 July and 31 December 2001, these cards are to be replaced by secure, computerized equivalents. The old cards may continue to be used until 31 December 2001. For the purposes of the handover, members of the personnel must go personally to the cards office (33/1-015), in order to fill in a 'fiche individuelle' form, taking the following documents for themselves and members of their families already in possession of a French card : A recent identity photograph in 4.5 cm x 3.5 cm format. The French card in their possession. An A4 photocopy of the same French card, certified by the cards office as being a true copy. Those members of the personnel whose cards (and/or cards belonging to members of their families) are shortly due to expire, or have recently done...

  6. REPLACEMENT OF FRENCH CARDS

    CERN Multimedia

    Human Resources Division; Cards.Service@cern.ch

    2001-01-01

    The French Ministry of Foreign Affairs is currently replacing all diplomatic cards, special cards and employment permits («attestations de fonctions») held by members of the personnel and their families. These cards are replaced by secure, computerized equivalents. The old cards may no longer be used after 31 December 2001. For the purposes of the handover, members of the personnel must go personally to the cards office (33/1-015) between 8h30 and 12h30, in order to fill in a «fiche individuelle» form, taking the following documents for themselves and members of their families already in possession of a French card : A recent identity photograph in 4.5 cm x 3.5 cm format, the French card in their possession, an A4 photocopy of the same French card, certified by the cards office as being a true copy. Those members of the personnel whose cards (and/or cards belonging to members of their families) are shortly due to expire, or have recently done so, are also requested...

  7. REPLACEMENT OF FRENCH CARDS

    CERN Multimedia

    Human Resources Division

    2001-01-01

    The French Ministry of Foreign Affairs has informed the Organization that it is shortly to replace all diplomatic cards, special cards and employment permits ('attestations de fonctions') now held by members of the personnel and their families. Between 2 July and 31 December 2001, these cards are to be replaced by secure, computerized equivalents. The old cards may continue to be used until 31 December 2001. For the purposes of the handover, members of the personnel are asked to go to the cards office (33/1-015), taking the following documents for themselves and members of their families already in possession of a French card : A recent identity photograph in 4.5 cm x 3.5 cm format, The French card in their possession, an A4 photocopy of the same French card, certified by the cards office as being a true copy. Those members of the personnel whose cards (and/or cards belonging to members of their families) are shortly due to expire, or have recently done so, are also requested to take these items to the c...

  8. REPLACEMENT OF FRENCH CARDS

    CERN Multimedia

    Human Resources Division

    2001-01-01

    The French Ministry of Foreign Affairs has informed the Organization that it is shortly to replace all diplomatic cards, special cards and employment permits ('attestations de fonctions') now held by members of the personnel and their families. Between 2 July and 31 December 2001, these cards are to be replaced by secure, computerized equivalents. A 'personnel office' stamped photocopy of the old cards may continue to be used until 31 December 2001. For the purposes of the handover, members of the personnel must go personally to the cards office (33/1-015), between 8:30 and 12:30, in order to fill a 'fiche individuelle' form (in black ink only), which has to be personally signed by themselves and another separately signed by members of their family, taking the following documents for themselves and members of their families already in possession of a French card : A recent identity photograph in 4.5 cm x 3.5 cm format (signed on the back) The French card in their possession an A4 photocopy of the same Fre...

  9. Total disc replacement.

    Science.gov (United States)

    Vital, J-M; Boissière, L

    2014-02-01

    Total disc replacement (TDR) (partial disc replacement will not be described) has been used in the lumbar spine since the 1980s, and more recently in the cervical spine. Although the biomechanical concepts are the same and both are inserted through an anterior approach, lumbar TDR is conventionally indicated for chronic low back pain, whereas cervical TDR is used for soft discal hernia resulting in cervicobrachial neuralgia. The insertion technique must be rigorous, with precise centering in the disc space, taking account of vascular anatomy, which is more complex in the lumbar region, particularly proximally to L5-S1. All of the numerous studies, including prospective randomized comparative trials, have demonstrated non-inferiority to fusion, or even short-term superiority regarding speed of improvement. The main implant-related complication is bridging heterotopic ossification with resulting loss of range of motion and increased rates of adjacent segment degeneration, although with an incidence lower than after arthrodesis. A sufficiently long follow-up, which has not yet been reached, will be necessary to establish definitively an advantage for TDR, particularly in the cervical spine. PMID:24412045

  10. Power Plant Replacement Study

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self-funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University’s aging and failing circa 1925 central steam production plant. Twenty-three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  11. Power Plant Replacement Study

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self-funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University's aging and failing circa 1925 central steam production plant. Twenty-three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  12. "Grand piano sign," a marker for proper femoral component rotation during total knee arthroplasty.

    Science.gov (United States)

    Moyad, Thomas F; Hughes, Richard E; Urquhart, Andrew

    2011-07-01

    A malpositioned femoral component is an established risk factor for patellar instability and pain after total knee arthroplasty (TKA). In the assessment of femoral rotation, several axes, including the transepicondylar axis, the posterior condylar axis, and the anteroposterior axis, are useful. However, these axes are not always easily applicable, particularly when significant deformity exists. An anecdotal method used by some surgeons involves assessing the shape of the anterior femoral surface osteotomy. Our observations from saw bone models and TKA led to our hypothesis that proper femoral component placement is indicated by a bimodal peak on the anterior femur, approximately twice as high on the lateral side than on the medial side. We use the term "grand piano sign" to describe the shape of the trochlea after the osteotomy is correctly completed. To our knowledge, this common observation has not been studied either in the laboratory or in vivo. Our cadaveric models demonstrated that the grand piano sign correlated with proper femoral rotation during TKA. Surgeons who are knowledgeable about this marker should find it helpful when orienting components during knee replacement surgery. PMID:22013571

  13. Charnley low-friction arthroplasty in teenage patients: the ultimate challenge.

    Science.gov (United States)

    Wroblewski, B M; Purbach, B; Siney, P D; Fleming, P A

    2010-04-01

    Increasing follow-up identifies the outcome in younger patients who have undergone total hip replacement (THR) and reveals the true potential for survival of the prosthesis. We identified 28 patients (39 THRs) who had undergone cemented Charnley low friction arthroplasty between 1969 and 2001. Their mean age at operation was 17.9 years (12 to 19) and the maximum follow-up was 34 years. Two patients (4 THRs) were lost to follow-up, 13 (16 THRs) were revised at a mean period of 19.1 years (8 to 34) and 13 (19 THRs) continue to attend regular follow-up at a mean of 12.6 years (2.3 to 29). In this surviving group one acetabular component was radiologically loose and all femoral components were secure. In all the patients the diameter of the femoral head was 22.225 mm with Charnley femoral components used in 29 hips and C-stem femoral components in ten. In young patients who require THR the acetabular bone stock is generally a limiting factor for the size of the component. Excellent long-term results can be obtained with a cemented polyethylene acetabular component and a femoral head of small diameter. PMID:20357322

  14. COMPUTERISED TOMOGRAPHIC STUDY OF HIP AND KNEE DIMENSIONS IN INDIAN FEMALES WITH ARTHROPLASTY PERSPECTIVE

    Directory of Open Access Journals (Sweden)

    Vinoth Kumar

    2014-10-01

    Full Text Available : INTRODUCTION: Hip and knee replacement surgeries have become one of the most commonly performed surgeries in India. Most of the arthroplasty implants are designed and manufactured based on western dimensions, which are not suited for some of the Indian females. In this study we measured the various dimensions of hip and knee using computerised tomography in 30 indian females. MATERIALS AND METHODS: We measured 8 parameters in the hip and 5 parameters in the knee with CT Scan in 30 females (30 hips,30 knees while maintaining a specified and fixed configuration while taking CT cuts.The parameters measured in the hip are Cup size, Cup version, Cup inclination, Head size, Neck shaft angle, Version of neck, Offset and diameter at the level of isthmus.The parameters measured in the knee are patellar thickness, Anteroposterior diameter of distal femur, Mediolateral diameter of distal femur, Anteroposterior diameter of proximal tibia, Mediolateral diameter of Proximal Tibia. RESULTS: We calculated the mean, median, range, standard error of the mean and subjected the values to KS test and P value test. The observations in different subjects are listed in the Tables. DISCUSSION: The measurements from these study are compared with the sizes of the smallest implant dimensions and recommendations for the implant sizing has been given.

  15. Complications of fixed infrared emitters in computer-assisted total knee arthroplasties

    Directory of Open Access Journals (Sweden)

    Suárez-Vázquez Abelardo

    2007-07-01

    Full Text Available Abstract Background The first stage in the implant of a total knee arthroplasty with computer-assisted surgery is to fasten the emitters to the femur and the tibia. These trackers must be hard-fixed to the bone. The objectives of our study are to evaluate the technical problems and complications of these tracker-pins, the necessary time to fix them to the bone and the possible advantages of a new femoral-fixed tracker-pin. Methods Three hundred and sixty seven tracker-pins were used in one hundred and fifty one computer-assisted total knee replacements. A bicortical screw was used to fix the tracker to the tibia in all cases; in the femur, however, a bicortical tracker was used in 112 cases, while a new device (OrthoLock with percutaneous fixation pins was employed in the remaining 39. Results Technical problems related to the fixing of the trackers appeared in nine cases (2.5%. The mean surgery time to fix the tracker pin to the tibia was 3 minutes (range 2–7, and 5 minutes in the case of the femoral pin (range: 4–11, although with the new tool it was only three minutes (range 2–4 (p Conclusion The incidence of problems and complications with the fixing systems used in knee navigation is very small. The use of a new device with percutaneous pins facilitates the fixing of femoral trackers and decreases the time needed to place them.

  16. The Arthroscopic Ulnohumeral Arthroplasty: From Mini-Open to Arthroscopic Surgery

    Directory of Open Access Journals (Sweden)

    Ilse Degreef

    2011-01-01

    Full Text Available In cubarthritis—osteoarthritis of the elbow—surgical procedures may be considered to debride the elbow joint to reduce pain, to increase mobility, and to postpone joint replacement surgery. The ulnohumeral arthroplasty as described by Outerbridge and Kashiwagi was originally introduced to debride both anterior and posterior elbow compartments through a direct posterior mini-open approach. To achieve this, a distal humeral fenestration throughout the humeral fossa is performed. Although with an elbow arthroscopy, a technique that was obviously developed later on, all compartments can be easily visualized. The arthroscopic fenestration of the humerus preserves its advantages, with good clinical results focused on pain relief and gaining mobility. On top, future elbow joint locking based on degenerative loose bodies can be prevented. Therefore, this surgery is often done in young, more active patients and even in sportsmen. These patients, however, need to be prompted to restrict loading on the elbow in the immediate postoperative period, because the elbow is biomechanically weakened and may be prone to a fracture. However, both outcome and postoperative rehabilitation are promising and the arthroscopic Outerbridge procedure is a reliable procedure with an easy rehabilitation. Therefore, the threshold is relatively low in early cubarthritis and recurrent locking of the elbow. In this paper, we present a literature review and the author's experience and own research on the Outerbridge procedure.

  17. The Patient’s Perspective of in-Home Telerehabilitation Physiotherapy Services Following Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    the Telage Researchers

    2013-08-01

    Full Text Available This study aimed at exploring patients’ perceptions regarding telerehabilitation services received post total knee replacement. In this qualitative embedded single case study, semi-structured interviews were conducted with five patients who had previously received in-home telerehabilitation post total knee arthroplasty. Participants were asked to reflect on their 8-week rehabilitation process and on their experience with the home telerehabilitation program. Interviews were transcribed and a qualitative thematic analysis was conducted. Six overarching themes emerged from the patients’ perceptions: (1 improving access to services with reduced need for transportation; (2 developing a strong therapeutic relationship with therapist while maintaining a sense of personal space; (3 complementing telerehabilitation with in-person visits; (4 providing standardized yet tailored and challenging exercise programs using telerehabilitation; (5 perceived ease-of-use of telerehabilitation equipment; and (6 feeling an ongoing sense of support. Gaining a better understating of the patient’s experience in telerehabilitation will be essential as programs continue to be developed and implemented.

  18. The Optimum Replacement of Weapon

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xiao; ZHANG Jin-chun

    2002-01-01

    The theory of LCC (Life Cycle Cost) is applied in this paper. The relation between the economic life of weapon and the optimum replacement is analyzed. The method to define the optimum replacement time of weapon is discussed.

  19. When to Replace a Prosthesis

    Science.gov (United States)

    ... to Replace a Prosthesis When to Replace a Prosthesis Web Development April 21, 2015 Fact Sheet Last ... workplace, they must be accurately fit with a prosthesis that matches their own anatomy; one that is ...

  20. Initial results of finger imaging using Photoacoustic Computed Tomography

    CERN Document Server

    van Es, Peter; Moens, Hein J Bernelot; Steenbergen, Wiendelt; Manohar, Srirang

    2014-01-01

    We present a photoacoustic computed tomography investigation on a healthy human finger, to image blood vessels with a focus on vascularity across the interphalangeal joints. The cross-sectional images were acquired using an imager specifically developed for this purpose. The images show rich detail of the digital blood vessels with diameters between 100 $\\mu$m and 1.5 mm in various orientations and at various depths. Different vascular layers in the skin including the subpapillary plexus could also be visualized. Acoustic reflections on the finger bone of photoacoustic signals from skin were visible in sequential slice images along the finger except at the location of the joint gaps. Not unexpectedly, the healthy synovial membrane at the joint gaps was not detected due to its small size and normal vascularization. Future research will concentrate on studying digits afflicted with rheumatoid arthritis to detect the inflamed synovium with its heightened vascularization, whose characteristics are potential marke...