WorldWideScience

Sample records for arthritis magnetic resonance

  1. Can magnetic resonance imaging differentiate undifferentiated arthritis?

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Duer, Anne; Hørslev-Petersen, K

    2005-01-01

    A high sensitivity for the detection of inflammatory and destructive changes in inflammatory joint diseases makes magnetic resonance imaging potentially useful for assigning specific diagnoses, such as rheumatoid arthritis and psoriatic arthritis in arthritides, that remain undifferentiated after...... conventional clinical, biochemical and radiographic examinations. With recent data as the starting point, the present paper describes the current knowledge on magnetic resonance imaging in the differential diagnosis of undifferentiated arthritis....

  2. Bone edema on magnetic resonance imaging is an independent predictor of rheumatoid arthritis development in patients with early undifferentiated arthritis

    DEFF Research Database (Denmark)

    Duer-Jensen, Anne; Hørslev-Petersen, Kim; Hetland, Merete Lund;

    2011-01-01

    To study magnetic resonance imaging (MRI) as a tool for early diagnosis of rheumatoid arthritis (RA) in patients with early undifferentiated arthritis (UA).......To study magnetic resonance imaging (MRI) as a tool for early diagnosis of rheumatoid arthritis (RA) in patients with early undifferentiated arthritis (UA)....

  3. Magnetic resonance imaging in rheumatoid arthritis advances and research priorities

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; McQueen, FM; Bird, P;

    2005-01-01

    Magnetic resonance imaging (MRI) has now been used extensively in cross-sectional and observational studies as well as in controlled clinical trials to assess disease activity and joint damage in rheumatoid arthritis (RA). MRI measurements or scores for erosions, bone edema, and synovitis have been...

  4. Ultrasound versus high field magnetic resonance imaging in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Tan, York Kiat; Østergaard, Mikkel; Bird, Paul;

    2014-01-01

    Over the past decade there have been significant advances in the field of musculoskeletal imaging, especially in the application of ultrasound (US) and magnetic resonance imaging (MRI) to the management of rheumatoid arthritis (RA). Both modalities offer significant advantages over the previous...

  5. Magnetic resonance imaging findings in horses with septic arthritis.

    Science.gov (United States)

    Easley, Jeremiah T; Brokken, Matthew T; Zubrod, Chad J; Morton, Alison J; Garrett, Katherine S; Holmes, Shannon P

    2011-01-01

    Fourteen horses with septic arthritis underwent high-field (1.5 T) magnetic resonance imaging (MRI). Septic arthritis was diagnosed based on results from historical and clinical findings, synovial fluid analyses and culture, and radiographic, ultrasonographic, arthroscopic, and histopathologic findings. MR findings included diffuse hyperintensity within bone and extracapsular tissue on fat-suppressed images in 14/14 horses (100%), joint effusion, synovial proliferation, and capsular thickening in 13/14 horses (93%), bone sclerosis in 11/14 horses (79%), and evidence of cartilage and subchondral bone damage in 8/14 horses (57%). Intravenous gadolinium was administered to five of the 14 horses and fibrin deposition was noted in all horses. Other findings after gadolinium administration included synovial enhancement in 4/5 (80%) horses, and bone enhancement in 1/5 (20%) horses. The MR findings of septic arthritis in horses were consistent with those reported in people. MRI may allow earlier and more accurate diagnosis of septic arthritis in horses as compared with other imaging modalities, especially when the clinical diagnosis is challenging. It also provides additional information not afforded by other methods that may influence and enhance treatment.

  6. Magnetic resonance imaging in rheumatoid arthritis advances and research priorities

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; McQueen, FM; Bird, P;

    2005-01-01

    Magnetic resonance imaging (MRI) has now been used extensively in cross-sectional and observational studies as well as in controlled clinical trials to assess disease activity and joint damage in rheumatoid arthritis (RA). MRI measurements or scores for erosions, bone edema, and synovitis have been......, and financial context of the study in question. We review the extent to which MRI assessments of joint erosion, bone edema, and synovitis fulfil these criteria, particularly as they relate to proof-of-concept RA clinical trials....

  7. Magnetic resonance imaging of the peripheral joints in psoriatic arthritis

    Directory of Open Access Journals (Sweden)

    M.A. Cimmino

    2011-09-01

    Full Text Available Objective: Magnetic resonance imaging (MRI has been widely used for the evaluation of rheumatoid arthritis (RA, with only a minority of studies considering other types of arthritis. This review is concerned with an evaluation of the MRI appearance of peripheral joints in psoriatic arthritis (PsA. Methods: A Medline search was performed to identify all publications from the years 1985 to 2006 concerning MRI of the peripheral joints and PsA. Additional papers were retrieved by scanning the references to the Medline-listed articles. Articles written in English, French, German, and Italian were included. Results: Most papers studied the hand and wrist, and only few of them were concerned with the knee, foot, temporomandibular joint, and elbow. Patients with PsA showed often, but not always, a pattern of joint inflammation which extended beyond the capsule into the extraarticular tissue. Bone oedema and erosions were less frequent than in RA. In particular, bone oedema at the entheseal junction was seen, especially in the knee. The degree of synovitis, assessed by dynamic MRI, was similar in PsA and RA. Discussion: Data on MRI of the peripheral joints in PsA are scanty. Only few studies were specifically designed to evaluate the pattern of arthritis in PsA, with most information deriving from papers where different types of arthritis were considered together. An enthesis-related origin of PsA has been proposed in contrast to the primarily synovial inflammation of RA. This pathogenic interpretation is likely to be true, but does not explain all cases of PsA, and needs to be confirmed by further studies.

  8. Magnetic resonance imaging in psoriatic arthritis: a review of the literature

    DEFF Research Database (Denmark)

    McQueen, F.M.; Lassere, M.; Østergaard, Mikkel

    2006-01-01

    of the disease process that cannot be gained using other imaging modalities. This review focuses on the literature on MRI in psoriatic arthritis published from 1996 to July 2005. The MRI features discussed include synovitis, tendonitis, dactylitis, bone oedema, bone erosions, soft tissue oedema, spondylitis....../sacroiliitis and subclinical arthropathy. Comparisons have been drawn with the more extensive literature describing the MRI features of rheumatoid arthritis and ankylosing spondylitis.......Psoriatic arthritis is a diverse condition that may be characterized by peripheral inflammatory arthritis, axial involvement, dactylitis and enthesitis. Magnetic resonance imaging (MRI) allows visualization of soft tissue, articular and entheseal lesions, and provides a unique picture...

  9. Significance of magnetic resonance imaging for early rheumatoid arthritis activity

    Directory of Open Access Journals (Sweden)

    E Y Pogozeva

    2009-01-01

    Full Text Available Objective. To assess possibility of magnetic resonance image (MRI application for rheu- matoid arthritis (RA activity and severity assessment.Material and methods. 100 pts with RA who fulfilled the 1987 ACR criteria with disease duration less than 12 months were included. Standard clinical examination with evaluation of tender and swollen joint counts, acute phase markers, hand and foot X-ray and hand MRI with 0,2 T Artoscan apparatus (ESAOTE Biomedica, Italy were performed.Results. MRI showed hand joint synovitis in 94,5%, erosions – in 67,3% of cases. X-ray examination revealed erosions in only 20,8% of pts. Localization of erosions revealed by X-ray and MRI coincided in 36,4% of cases and in 61,8% of pts erosions were detected only by MRI. MRI confirmed clinical conclusion about presence or absence of metacarpophalangeal and wrist joint synovitis in 64,5% and 74,5% of cases respectively. In8,2% and 21,8% MRI revealed signs of synovitis in clinically intact joints. MRI synovitis score correlated with clinical and laboratory measures of disease activity – DAS 28 (r=0,37, p=0,001, CRP(r=0,30, p=0,001, ESR (r=0,42, p=0,001, HAQ (r=0,24, p=0,001. Weak correlation was revealed between ESR and presence of erosions (r=0,29, CRP, ESR and MRI signs of bone marrow edema (r=0,27, p=0,005 and r=0,29, p=0,002 respectively. Relationship between laboratory and clinical features was weaker and referred only to CRP level and swollen joint count (p=0,05.Conclusion. MRI signs may be used as additional and independent measures of inflammatory activity (particularly synovitis score and severity of RA

  10. Developing a magnetic resonance imaging scoring system for peripheral psoriatic arthritis

    DEFF Research Database (Denmark)

    McQueen, Fiona; Lassere, Marissa; Bird, Paul;

    2007-01-01

    We describe the first steps in developing an OMERACT magnetic resonance imaging (MRI) scoring system for peripheral psoriatic arthritis (PsA). A preexisting MRI dataset (finger joints) from 10 patients with PsA was scored by 4 readers for bone erosion, bone edema, synovitis, tendinopathy, and ext......We describe the first steps in developing an OMERACT magnetic resonance imaging (MRI) scoring system for peripheral psoriatic arthritis (PsA). A preexisting MRI dataset (finger joints) from 10 patients with PsA was scored by 4 readers for bone erosion, bone edema, synovitis, tendinopathy...

  11. Magnetic resonance imaging of the shoulder in patients with rheumatoid arthritis.

    OpenAIRE

    Kieft, G. J.; Dijkmans, B A; Bloem, J. L.; Kroon, H.M.

    1990-01-01

    To evaluate the ability of magnetic resonance imaging (MRI) to detect shoulder abnormalities 18 patients (36 shoulders) with rheumatoid arthritis (RA) and shoulder complaints were studied. Osseous abnormalities of the glenoid and humeral head were readily detected with MRI. The imaging planes used were not suitable for the evaluation of acromioclavicular joint involvement. Magnetic resonance imaging depicted soft tissue abnormalities that were not clearly visualised by plain film radiography,...

  12. Developing a magnetic resonance imaging scoring system for peripheral psoriatic arthritis

    DEFF Research Database (Denmark)

    McQueen, Fiona; Lassere, Marissa; Bird, Paul;

    2007-01-01

    We describe the first steps in developing an OMERACT magnetic resonance imaging (MRI) scoring system for peripheral psoriatic arthritis (PsA). A preexisting MRI dataset (finger joints) from 10 patients with PsA was scored by 4 readers for bone erosion, bone edema, synovitis, tendinopathy, and...

  13. The OMERACT-RAMRIS Rheumatoid Arthritis Magnetic Resonance Imaging Joint Space Narrowing Score

    DEFF Research Database (Denmark)

    Møller Døhn, Uffe; Conaghan, Philip G; Eshed, Iris;

    2014-01-01

    To test the intrareader and interreader reliability of assessment of joint space narrowing (JSN) in rheumatoid arthritis (RA) wrist and metacarpophalangeal (MCP) joints on magnetic resonance imaging (MRI) and computed tomography (CT) using the newly proposed OMERACT-RAMRIS JSN scoring method, and...... to compare JSN assessment on MRI, CT, and radiography....

  14. OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Summary of OMERACT 6 MR Imaging Module

    DEFF Research Database (Denmark)

    McQueen, F; Lassere, M; Edmonds, J;

    2003-01-01

    Magnetic resonance image (MRI) scanning is a new method for imaging and quantifying joint inflammation and damage in rheumatoid arthritis (RA). Over the past 4 years, the OMERACT MR Imaging Group has been developing and testing the RA-MRI scoring system (RAMRIS) for use in RA. The OMERACT filter...

  15. The OMERACT Magnetic Resonance Imaging Inflammatory Arthritis Group - advances and priorities

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; McQueen, Fiona; Bird, Paul;

    2007-01-01

    This article updates the work and research priorities of the OMERACT working group on magnetic resonance imaging (MRI) in inflammatory arthritis, as presented to the OMERACT 8 meeting in Malta in May 2006. This work focused on testing the reliability of dedicated extremity MRI in rheumatoid arthr...

  16. Magnetic resonance imaging for diagnosing, monitoring and prognostication in psoriatic arthritis

    DEFF Research Database (Denmark)

    Poggenborg, René Panduro; Sørensen, Inge Juul; Pedersen, Susanne Juhl;

    2015-01-01

    Psoriatic arthritis (PsA) is a chronic systemic, inflammatory disease associated with skin psoriasis. PsA may be difficult to assess with clinical examination and blood tests because of its complex and multifaceted clinical presentation. Magnetic resonance imaging (MRI) can visualise all peripheral...

  17. The OMERACT Magnetic Resonance Imaging Inflammatory Arthritis Group - advances and priorities

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; McQueen, Fiona; Bird, Paul;

    2007-01-01

    This article updates the work and research priorities of the OMERACT working group on magnetic resonance imaging (MRI) in inflammatory arthritis, as presented to the OMERACT 8 meeting in Malta in May 2006. This work focused on testing the reliability of dedicated extremity MRI in rheumatoid...

  18. Low-cost, low-field dedicated extremity magnetic resonance imaging in early rheumatoid arthritis

    DEFF Research Database (Denmark)

    Lindegaard, H M; Vallø, J; Hørslev-Petersen, K;

    2006-01-01

    OBJECTIVE: To study the ability of low-cost low-field dedicated extremity magnetic resonance imaging (E-MRI) to assess and predict erosive joint damage in the wrist and metacarpophalangeal (MCP) joints of patients with early rheumatoid arthritis. METHODS: 24 previously untreated patients with...... rheumatoid arthritis with joint symptoms for <1 year were evaluated at the time of diagnosis and after 6 and 12 months of methotrexate treatment with conventional clinical or biochemical examinations, x rays of both hands and wrists, and E-MRI of the dominant wrist and MCP joints. RESULTS: At baseline, all...... arthritis who were treated uniformly, baseline E-MRI erosions in MCP or wrist bones markedly increased the risk of x ray erosions at the 1-year follow-up. Low-cost, low-field dedicated extremity MRI is promising for assessment and prognostication of early rheumatoid arthritis....

  19. Magnetic resonance imaging and bone scintigraphy in the differential diagnosis of unclassified arthritis

    DEFF Research Database (Denmark)

    Duer, Anne; Østergaard, M; Hørslev-Petersen, K;

    2008-01-01

    OBJECTIVES: To investigate the value in clinical practice of hand magnetic resonance imaging (MRI) and whole body bone scintigraphy in the differential diagnosis of patients with unclassified arthritis. METHODS: 41 patients with arthritis (> or = 2 swollen joints, > 6 months' duration) which...... joints of the most symptomatic hand and whole body bone scintigraphy were performed. Two rheumatologists agreed on the most likely diagnosis and the patients were treated accordingly. A final diagnosis was made by another specialist review 2 years later. RESULTS: Tentative diagnoses after MRI and bone...

  20. Magnetic resonance imaging of the wrist in early rheumatoid arthritis: a pictorial essay

    International Nuclear Information System (INIS)

    This pictorial essay describes the changes seen in the wrist in early rheumatoid arthritis (RA) on MRI. Magnetic resonance imaging can demonstrate bone erosions, bone marrow signal changes, synovitis and tenosynovitis in early rheumatoid arthritis. Magnetic resonance imaging of the wrist can identify erosions in RA earlier than plain radiographs and can detect more erosions. Common sites include the capitate, lunate and scaphoid. Bone marrow signal changes occur frequently and are most common in the capitate, lunate and triquetrum. Synovial thickening and enhancement are clearly demonstrated with MRI and are most commonly seen in the radiocarpal joint (RCJ). Tenosynovitis can be seen in the wrist in more than half of patients presenting with RA. This most commonly involves the extensor carpi ulnaris tendon and is seen as sheath fluid, thickening and enhancement. Copyright (2001) Blackwell Science Pty Ltd

  1. OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Exercise 3: an international multicenter reliability study using the RA-MRI Score

    DEFF Research Database (Denmark)

    Lassere, M; McQueen, F; Østergaard, Mikkel;

    2003-01-01

    We examined inter-reader agreement of the revised OMERACT 5 Rheumatoid Arthritis MRI Score (RAMRIS v3). Magnetic resonance (MR) images of 10 sets of metacarpophalangeal (MCP) joints 2-5 and 8 sets of rheumatoid arthritis (RA) wrists [1.5 T, coronal and axial T1 and T2 spin-echo, +/- fat saturation...

  2. Magnetic resonance imaging in psoriatic arthritis -- update on current status and future perspectives

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Poggenborg, René Panduro

    2012-01-01

    The potential of magnetic resonance imaging (MRI) for use in clinical practice and research has gained increasing interest over the last decade. International collaborative initiatives from GRAPPA (Group for Research and Assessment of Psoriasis and Psoriatic Arthritis) and/or OMERACT (Outcome...... Measures in Rheumatology) may contribute to facilitating research, identifying appropriate areas for use, and reaching consensus on the optimal examination technique. Accordingly, GRAPPA, a primary driver of international research in psoriasis and psoriatic arthritis (PsA), has focused on the current use...... and future development of MRI and other modern imaging modalities in PsA. This review, presented at the GRAPPA 2010 annual meeting, describes the current status of MRI in PsA, with a focus on its use in diagnosis, monitoring, and prediction of the disease course and treatment response. Important areas...

  3. Imaging in early rheumatoid arthritis: roles of magnetic resonance imaging, ultrasonography, conventional radiography and computed tomography

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Ejbjerg, Bo; Szkudlarek, Marcin

    2005-01-01

    Efficient methods for diagnosis, monitoring and prognostication are essential in early rheumatoid arthritis (RA). While conventional X-rays only visualize the late signs of preceding disease activity, there is evidence for magnetic resonance imaging (MRI) and ultrasonography being highly sensitive...... for early inflammatory and destructive changes in RA joints, and for MRI findings being sensitive to change and of predictive value for future progressive X-ray damage. Reviewing the data on X-ray, computed tomography, MRI and ultrasonography in RA, this paper discusses current and future roles...

  4. Development and preliminary validation of a magnetic resonance imaging joint space narrowing score for use in rheumatoid arthritis: potential adjunct to the OMERACT RA MRI scoring system

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Bøyesen, Pernille; Eshed, Iris;

    2011-01-01

    To develop and validate a magnetic resonance imaging (MRI) method of assessment of joint space narrowing (JSN) in rheumatoid arthritis (RA).......To develop and validate a magnetic resonance imaging (MRI) method of assessment of joint space narrowing (JSN) in rheumatoid arthritis (RA)....

  5. A multicenter reliability study of extremity-magnetic resonance imaging in the longitudinal evaluation of rheumatoid arthritis

    DEFF Research Database (Denmark)

    Conaghan, Philip G; Ejbjerg, Bo; Lassere, Marissa;

    2007-01-01

    There are limited data on the reliability of extremity magnetic resonance imaging (E-MRI) in the longitudinal evaluation of rheumatoid arthritis (RA). Our aim was to assess the interreader reliability of the OMERACT RA MRI score in the assessment of change in disease activity and bone erosion sco...

  6. OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Exercise 5: an international multicenter reliability study using computerized MRI erosion volume measurements

    DEFF Research Database (Denmark)

    Bird, P; Ejbjerg, B; McQueen, F;

    2003-01-01

    Scoring erosions on magnetic resonance imaging (MRI) is one method of estimating damage in patients with rheumatoid arthritis (RA), but it has limitations. The aim of this pilot study was to assess the feasibility and inter-reader reliability of computer assisted erosion volume estimation...

  7. [Magnetic resonance imaging in juvenile idiopathic arthritis: peculiarities of imaging children].

    Science.gov (United States)

    Navallas, M; Rebollo Polo, M; Riaza, L; Muchart López, J; Maristany, T

    2013-09-01

    The term juvenile idiopathic arthritis (JIA) encompasses a heterogeneous group of arthritides with no known cause that begin before the age of 16 years and persist for at least 6 weeks. In recent decades, imaging techniques have acquired a fundamental role in the diagnosis and follow-up of JIA, owing to the unification of the different criteria for classification, which has strengthened the research in this field, and to the development of disease-modifying antirheumatic drugs. In this article, we briefly explain what JIA is. Moreover, we describe the role and limitations of plain-film radiography, ultrasonography, and magnetic resonance imaging (MRI). Finally, we review the MRI protocol and findings, and we comment on the differential diagnosis.

  8. Magnetic resonance imaging of soft tissue changes in rheumatoid arthritis wrist joints

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Szkudlarek, Marcin

    2001-01-01

    , tendonitis, enthesitis, joint effusions, and ligament and tendon tears, can be visualized. Unfortunately, the image resolution in most clinically available MR units is insufficient for evaluation of wrist joint cartilage. Preliminary data suggest that MRI is a valuable tool in the diagnosis and......An increasingly aggressive therapeutic strategy, improved treatment options, and encouraging preliminary results have attracted growing attention to the potential of magnetic resonance imaging (MRI) in the diagnosis, prognostication, and monitoring of rheumatoid arthritis (RA). MRI offers...... prognostication of RA. The superior sensitivity of MRI may be of major significance in both clinical trials and practice. In trials, MRI may allow reductions in the trial size and length because of its more sensitive separation of responders from nonresponders. Thus, although thorough validation is awaited...

  9. OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Summary of OMERACT 6 MR Imaging Module

    DEFF Research Database (Denmark)

    McQueen, F; Lassere, M; Edmonds, J;

    2003-01-01

    Magnetic resonance image (MRI) scanning is a new method for imaging and quantifying joint inflammation and damage in rheumatoid arthritis (RA). Over the past 4 years, the OMERACT MR Imaging Group has been developing and testing the RA-MRI scoring system (RAMRIS) for use in RA. The OMERACT filter...... correlates closely with histological evidence and work continues on validating MR erosions with reference to radiographic techniques. The RAMRIS has demonstrated good reliability for bone erosion and synovitis at the wrists and metacarpophalangeal joints subject to reader training, with slightly lower levels...... of reader agreement for bone edema. Reliability was less satisfactory in discriminating between 2 time points, and further work is required if the score is to be used to monitor change. Feasibility also needs to be considered for the practical application of the score, including the time taken for scanning...

  10. Determining a Magnetic Resonance Imaging Inflammatory Activity Acceptable State Without Subsequent Radiographic Progression in Rheumatoid Arthritis

    DEFF Research Database (Denmark)

    Gandjbakhch, Frédérique; Haavardsholm, Espen A; Conaghan, Philip G;

    2014-01-01

    OBJECTIVE: To assess the predictive value of magnetic resonance imaging (MRI)-detected subclinical inflammation for subsequent radiographic progression in a longitudinal study of patients with rheumatoid arthritis (RA) in clinical remission or low disease activity (LDA), and to determine cutoffs...... for an MRI inflammatory activity acceptable state in RA in which radiographic progression rarely occurs. METHODS: Patients with RA in clinical remission [28-joint Disease Activity Score-C-reactive protein (DAS28-CRP) LDA state (2.6 ≤ DAS28-CRP ....4 (95% CI 1.72-11.4) for radiographic progression. CONCLUSION: High MRI synovitis score predicts radiographic progression in patients in clinical remission/LDA. A cutoff point for determining an MRI inflammatory activity acceptable state based on the RAMRIS synovitis score was established. Incorporating...

  11. Reliability and responsiveness of dynamic contrast-enhanced magnetic resonance imaging in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Axelsen, M.B.; Poggenborg, R.P.; Stoltenberg, M.;

    2013-01-01

    Objectives: To investigate the responsiveness to treatment and the reliability of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in rheumatoid arthritis (RA) knee joints. Methods: DCE-MRI was performed in 12 clinically active RA knee joints before and 1, 7, 30, and 180 days after...... semi-automatic software is a reliable and responsive tool for assessing treatment in RA knees joints. Rough manual delineation of the joint to omit enhancement artefacts is necessary....... clinical remission of the knee was achieved at day 7. All DCE-MRI parameters decreased from day 0 to day 7. Using the Quick and Precise ROI methods, respectively, IRE decreased by 63% and 69%, ME decreased by 11% and 11%, Nvoxel decreased by 55% and 57%, and IRE Nvoxel decreased by 84% and 85%. The intra...

  12. The OMERACT psoriatic arthritis magnetic resonance imaging scoring system (PsAMRIS): definitions of key pathologies, suggested MRI sequences, and preliminary scoring system for PsA Hands

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; McQueen, Fiona; Wiell, Charlotte;

    2009-01-01

    This article describes a preliminary OMERACT psoriatic arthritis magnetic resonance image scoring system (PsAMRIS) for evaluation of inflammatory and destructive changes in PsA hands, which was developed by the international OMERACT MRI in inflammatory arthritis group. MRI definitions of importan...... pathologies in peripheral PsA and suggestions concerning appropriate MRI sequences for use in PsA hands are also provided.......This article describes a preliminary OMERACT psoriatic arthritis magnetic resonance image scoring system (PsAMRIS) for evaluation of inflammatory and destructive changes in PsA hands, which was developed by the international OMERACT MRI in inflammatory arthritis group. MRI definitions of important...

  13. MAGNETIC RESONANCE IMAGING OF THE SACROILIAC JOINT IN DIFFERENTIAL DIAGNOSIS OF EARLY POLYARTICULAR PSORIATIC AND RHEUMATOID ARTHRITIS (STUDY DATA REMARKA)

    OpenAIRE

    Elena Yu Loginova; T. V. Korotaeva; E L Luchihina; Smirnov, A. V.; A A Glazkov; D E Karateev

    2014-01-01

    Diagnosis of lesions of the spine and sacroiliac joints may be helpful in discrimination between early psoriatic arthritis (ePsA) and early rheumatoid arthritis (eRA).Objective. To assess the significance of inflammatory back pain (IBP), HLA-B27, and active sacroiliitis (ASI) confirmed by magnetic resonance imaging (MRI) for differential diagnosis of polyarticular ePsA and eRA.Materials and Methods. The study included 29 patients with ePsA (13 males and 16 females, mean age 36.52 ± 11.27 year...

  14. Power Doppler ultrasonography for assessment of synovitis in the metacarpophalangeal joints of patients with rheumatoid arthritis: a comparison with dynamic magnetic resonance imaging

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, M; Strandberg, C;

    2001-01-01

    OBJECTIVE: To evaluate the effectiveness of power Doppler ultrasonography (PDUS) for assessing inflammatory activity in the metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA), using dynamic magnetic resonance imaging (MRI) as a reference method. METHODS: PDUS and dynamic...

  15. Patterns of magnetic resonance imaging bone erosion in rheumatoid arthritis--which bones are most frequently involved and show the most change?

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Møller Døhn, Uffe; Duer-Jensen, A;

    2011-01-01

    To investigate by magnetic resonance imaging (MRI) which bones in wrists and metacarpophalangeal (MCP) joints most frequently show bone erosions, and which most frequently demonstrate erosive progression, in early and established rheumatoid arthritis (RA).......To investigate by magnetic resonance imaging (MRI) which bones in wrists and metacarpophalangeal (MCP) joints most frequently show bone erosions, and which most frequently demonstrate erosive progression, in early and established rheumatoid arthritis (RA)....

  16. Patterns of magnetic resonance imaging bone erosion in rheumatoid arthritis - which bones are most frequently involved and show the most change?

    DEFF Research Database (Denmark)

    Ostergaard, Mikkel; Møller Døhn, Uffe; Duer-Jensen, Anne;

    2011-01-01

    To investigate by magnetic resonance imaging (MRI) which bones in wrists and metacarpophalangeal (MCP) joints most frequently show bone erosions, and which most frequently demonstrate erosive progression, in early and established rheumatoid arthritis (RA).......To investigate by magnetic resonance imaging (MRI) which bones in wrists and metacarpophalangeal (MCP) joints most frequently show bone erosions, and which most frequently demonstrate erosive progression, in early and established rheumatoid arthritis (RA)....

  17. Dynamic contrast-enhanced magnetic resonance imaging of the wrist in early arthritis

    Directory of Open Access Journals (Sweden)

    M.A. Cimmino

    2011-09-01

    Full Text Available Objectives: MRI has been proposed as the imaging method of choice to evaluate the long-term outcome in patients with early arthritis. The role of dynamic MRI, performed at presentation, in predicting the outcome of patients with early arthritis has been addressed in the present study. Methods: 39 patients with early arthritis, involving at least one wrist, were studied with clinical visits and laboratory investigations, every 3 months. Dynamic MRI was performed with a low-field (0.2T, extremity-dedicated machine (Artoscan, Esaote, Genova, Italy equipped with a permanent magnet and with a dedicated hand and wrist coil. During the intravenous injection of Gd-DTPA, twenty consecutive fast images of 3 slices of the wrist were acquired. The synovial contrast enhancement ratio was calculated both as rate of early enhancement (REE per second during the first 55” and as relative enhancement (RE at t seconds. Results: In our cohort of patients, REE and RE were significantly lower than those observed in a historical cohort of 36 patients with active rheumatoid arthritis. In univariate analysis, low RE predicted complete remission of arthritis. In multivariate analysis, fulfillment of RA criteria during follow-up was predicted by high RE. The need for immunosuppressive treatment at the end of follow-up was predicted by both low RE and high REE. Conclusions: Dynamic MRI may be used to predict several outcomes of early arthritis involving the wrist

  18. The early magnetic resonance imaging features of the knee in juvenile idiopathic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Karl; Wittkop, Berndt; Haigh, Fiona; Ryder, Clive; Gardner-Medwin, Janet M

    2002-06-01

    AIMS: Early diagnosis of juvenile idiopathic arthritis (JIA) facilitates earlier more aggressive therapy, and improved outcome. Recognition of the features of early, untreated JIA on magnetic resonance imaging (MRI) will improve disease detection and expedite treatment. This study aims to highlight the relevant MRI features. METHODS: MRI examinations of the knee joint were performed on 11 children with clinically confirmed, early, untreated JIA. The MRI images were obtained at a mean of 2 months after symptom onset and independently evaluated by two consultant paediatric radiologists. RESULTS: Abnormalities were found on all MRI examinations. Synovial hypertrophy, joint effusions, popliteal lymph nodes and soft tissue swelling were present in all patients. Gadolinium DTPA enhancement improved the detection of synovial hyperplasia. Metaphyseal splaying and condylar overgrowth were seen in five cases (41%), oedema of the lateral collateral ligament in two cases (18%) and superficial cartilage thinning in one case. Bony erosions and deep cartilage destruction were not demonstrated. CONCLUSION: MRI of the knee joint identifies early joint changes which are distinct from those in later disease. The presence of these features should alert the radiologist to the possible diagnosis of JIA and post gadolinium DTPA sequences should be performed. Gadolinium DPTA enhancement increases the sensitivity for the detection of inflammatory changes in JIA. Johnson, K. et al. (2002)

  19. Temporomandibular joint involvement in juvenile idiopathic arthritis: clinical predictors of magnetic resonance imaging signs

    Energy Technology Data Exchange (ETDEWEB)

    Argyropoulou, Maria I.; Margariti, Persefoni N.; Astrakas, Loukas; Kosta, Paraskevi [Medical School University of Ioannina, Department of Radiology, Ioannina (Greece); Karali, Aikaterini; Alfandaki, Sapfo; Siamopoulou, Antigoni [University of Ioannina, Department of Child Health, Medical School, Ioannina (Greece)

    2009-03-15

    The aim of the study was to define clinical predictors of magnetic resonance imaging (MRI) findings of temporomandibular joint (TMJ) involvement in juvenile idiopathic arthritis (JIA). Forty-six patients, aged 2.08-36.7 years, with JIA (oligoartitular 18, polyarticular 17, systemic type 11) were examined with standard plain and contrast-enhanced sequences. Of 88 TMJs examined, an abnormal condyle was observed in 32%, flattened articular eminence in 27%, flattened articular disk in 17%, intra-articular fluid in 10%, enhancing pannus in 45% and restricted condylar motion in 9%. Logistic regression analysis revealed that for abnormal condyle and flattened articular eminence, independent predictors were type of JIA (P < 0.015), age at onset (P < 0.038), and duration of disease activity (P < 0.001). Plots of the logistic regression models showed that TMJ involvement approached certainty for systemic sooner than for the other JIA types. Pannus was present with probability >0.5 when the disease started before 4 years of age. In conclusion, the systemic type of JIA, young age at onset and long duration of activity are risk factors for TMJ damage. MRI of the TMJ should be performed in patients who are less than 4 years of age at the onset of JIA, and in those with the systemic type, whatever the age of onset. (orig.)

  20. Evaluation of rheumatoid arthritis using a scoring system devised from magnetic resonance imaging of rheumatoid knees

    International Nuclear Information System (INIS)

    We studied the magnetic resonance imaging (MRI) of 120 knees in 86 rheumatoid arthritis (RA) patients and of 14 unaffected knees in 12 control cases. We also developed a scoring system as a quantitative analysis method. We divided the MRI into 10 items, and classified the severity of the symptoms into 4 grades (score 0 to 3). The average total score increased according to the radiographic grade. Soft tissue lesions were clearly detected, even in the early stages of RA. Items such as synovial proliferation showed a high score even in the early stages, suggesting that it was the initial symptom of RA. The score also showed a correlation with the inflammatory signs. These results suggest that this scoring system is very sensitive and yields a good reflection of RA activity. We demonstrated that this system is simple and convenient for routine diagnostic use. We further demonstrated that it is useful for following the advancement of RA and for evaluating the response to treatment. (author)

  1. Detection of bone erosions in rheumatoid arthritis wrist joints with magnetic resonance imaging, computed tomography and radiography

    DEFF Research Database (Denmark)

    Døhn, Uffe Møller; Ejbjerg, Bo J; Hasselquist, Maria;

    2008-01-01

    BACKGROUND: The objectives of the present study were, with multidetector computed tomography (CT) as the reference method, to determine the performance of magnetic resonance imaging (MRI) and radiography for the detection of bone erosions in rheumatoid arthritis wrist bones, and to test whether...... measuring volumes of erosions on CT and MRI is reproducible and correlated to semiquantitative assessments (scores) of erosions on CT, MRI and radiography. METHODS: Seventeen patients with rheumatoid arthritis and four healthy control individuals underwent CT, MRI and radiography of one wrist, performed on...... the same day. CT was performed on a Philips Mx8000IDT unit (voxel size 0.4 mm x 0.4 mm x 1 mm) and MRI was performed on a Philips Panorama 0.6T unit (voxel size 0.4 mm x 0.4 mm x 0.4 mm). Images were evaluated separately for erosions in all wrist bones and were scored according to the principles of...

  2. Reliability and sensitivity to change of the OMERACT rheumatoid arthritis magnetic resonance imaging score in a multireader, longitudinal setting

    DEFF Research Database (Denmark)

    Haavardsholm, ea; Østergaard, Mikkel; Kvan, NP;

    2005-01-01

    OBJECTIVE: To assess the intra- and interreader reliability and the sensitivity to change of the Outcome Measures in Rheumatology Clinical Trials (OMERACT) Rheumatoid Arthritis Magnetic Resonance Imaging Score (RAMRIS) system on digital images of the wrist joints of patients with early or...... established rheumatoid arthritis (RA). METHODS: Ten sets of baseline and 1-year followup MR images of the wrists of patients with progressive changes on conventional hand radiographs were scored independently by 4 readers on 2 consecutive days, preceded by reader training and calibration. The MR images were...... acquired and scored according to the recommendations from the OMERACT MRI group. The intra- and interreader agreement (evaluated by intraclass correlation coefficients [ICCs]) and the sensitivity to change (evaluated by the smallest detectable difference [SDD]) were determined for scores of synovitis...

  3. Introduction of a novel magnetic resonance imaging tenosynovitis score for rheumatoid arthritis: reliability in a multireader longitudinal study

    DEFF Research Database (Denmark)

    Haavardsholm, Espen A; Østergaard, Mikkel; Ejbjerg, Bo J;

    2007-01-01

    OBJECTIVES: To describe a novel scoring system for the assessment of tenosynovitis by magnetic resonance imaging (MRI) in patients with rheumatoid arthritis, and assess its intra- and inter-reader reliability in a multireader, longitudinal setting. METHODS: Flexor and extensor tenosynovitis were...... evaluated at the level of the wrist in 10 different anatomical areas, graded semi-quantitatively from grade 0 to 3 (total score 0-30), based on the maximum width of post-contrast enhancement within each anatomical area on axial T1-weighted MR images. Ten sets of baseline and 1-year follow-up MR images of...... the wrists of patients with rheumatoid arthritis with early and established disease were scored independently by four readers twice on 2 consecutive days. Intra- and inter-reader agreements were evaluated....

  4. Dynamic magnetic resonance imaging of the metacarpophalangeal joints in rheumatoid arthritis, early unclassified polyarthritis, and healthy controls

    DEFF Research Database (Denmark)

    Klarlund, Mette; Østergaard, Mikkel; Rostrup, Egill;

    2000-01-01

    OBJECTIVE: To introduce dynamic magnetic resonance imaging (MRI) as an indicator of inflammatory activity in the metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA) or early unclassified polyarthritis, and to compare the results with a healthy control group. MATERIALS...... AND METHODS: We examined 42 RA and 23 early unclassified polyarthritis patients, and 12 healthy controls in a cross-sectional study. Dynamic MRI (repeated FLASH-MR images after injection of a contrast agent) was performed through the 2nd to the 5th MCP joint. Two methods for identification of the enhancing...

  5. Magnetic resonance imaging findings in 84 patients with early rheumatoid arthritis: bone marrow oedema predicts erosive progression

    DEFF Research Database (Denmark)

    Haavardsholm, E.A.; Boyesen, P.; Østergaard, Morten;

    2008-01-01

    images were scored according to the OMERACT rheumatoid arthritis magnetic resonance imaging score (RAMRIS), and conventional radiographs according to the van der Heijde modified Sharp score. RESULTS: MRI findings reflecting inflammation (synovitis, bone marrow oedema and tenosynovitis) decreased during...... (odds ratio = 2.77 (95% confidence interval (CI) 1.06 to 7.21)) and MRI erosive progression (B = 0.21 (95% CI 0.08 to 0.34)). CONCLUSIONS: MRI findings were common in early RA, and MRI bone marrow oedema was an independent predictor of radiographic damage. These results suggest that MRI scans...

  6. Dynamic magnetic resonance imaging of the metacarpophalangeal joints in rheumatoid arthritis, early unclassified polyarthritis, and healthy controls

    DEFF Research Database (Denmark)

    Klarlund, Mette; Østergaard, Mikkel; Rostrup, Egill;

    2000-01-01

    AND METHODS: We examined 42 RA and 23 early unclassified polyarthritis patients, and 12 healthy controls in a cross-sectional study. Dynamic MRI (repeated FLASH-MR images after injection of a contrast agent) was performed through the 2nd to the 5th MCP joint. Two methods for identification of the enhancing......OBJECTIVE: To introduce dynamic magnetic resonance imaging (MRI) as an indicator of inflammatory activity in the metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA) or early unclassified polyarthritis, and to compare the results with a healthy control group. MATERIALS...

  7. Introduction of a novel magnetic resonance imaging tenosynovitis score for rheumatoid arthritis: reliability in a multireader longitudinal study

    DEFF Research Database (Denmark)

    Haavardsholm, Espen A; Østergaard, Mikkel; Ejbjerg, Bo J;

    2007-01-01

    OBJECTIVES: To describe a novel scoring system for the assessment of tenosynovitis by magnetic resonance imaging (MRI) in patients with rheumatoid arthritis, and assess its intra- and inter-reader reliability in a multireader, longitudinal setting. METHODS: Flexor and extensor tenosynovitis were...... evaluated at the level of the wrist in 10 different anatomical areas, graded semi-quantitatively from grade 0 to 3 (total score 0-30), based on the maximum width of post-contrast enhancement within each anatomical area on axial T1-weighted MR images. Ten sets of baseline and 1-year follow-up MR images...

  8. Significant improvement in synovitis, osteitis, and bone erosion following golimumab and methotrexate combination therapy as compared with methotrexate alone: A magnetic resonance imaging study of 318 methotrexate-naive rheumatoid arthritis patients

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Emery, Paul; Conaghan, Philip G;

    2011-01-01

    To evaluate the effects of golimumab on inflammation/structural damage detected by magnetic resonance imaging (MRI) in patients with rheumatoid arthritis (RA).......To evaluate the effects of golimumab on inflammation/structural damage detected by magnetic resonance imaging (MRI) in patients with rheumatoid arthritis (RA)....

  9. OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Core set of MRI acquisitions, joint pathology definitions, and the OMERACT RA-MRI scoring system

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Peterfy, C; Conaghan, P;

    2003-01-01

    This article describes the 2002 OMERACT rheumatoid arthritis magnetic resonance image scoring system (RAMRIS) for evaluation of inflammatory and destructive changes in RA hands and wrists, which was developed by an international MRI-OMERACT group. MRI definitions of important RA joint pathologies......, and a 'core set' of basic MRI sequences for use in RA are also suggested......This article describes the 2002 OMERACT rheumatoid arthritis magnetic resonance image scoring system (RAMRIS) for evaluation of inflammatory and destructive changes in RA hands and wrists, which was developed by an international MRI-OMERACT group. MRI definitions of important RA joint pathologies...

  10. Golimumab therapy-induced indicators of X-ray inflammation progression and magnitude according to magnetic resonance imaging evidence in patients with rheumatoid arthritis, ankylosing spondylitis, or psoriatic arthritis

    Directory of Open Access Journals (Sweden)

    Aleksandr Viktorovich Smirnov

    2013-01-01

    Full Text Available The paper gives data on the progression of X-ray and magnetic resonance imaging changes in the hand and foot joints of patients with rheumatoid arthritis and psoriatic arthropathy and in the axial skeleton of those with ankylosing spondylitis when golimumab is used. Golimumab therapy is shown to retard the progression of structural changes in the peripheral joints and vertebral column. There is a significant correlation between magnetic resonance imaging evidence and blood C-reactive protein concentrations.

  11. Radiological imaging in early diagnosis of rheumatoid arthritis. The role of ultrasound and magnetic resonance imaging; Radiologische Fruehdiagnostik der rheumatoiden Arthritis. Stellenwert von Ultraschall und Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Platzgummer, H.; Schueller-Weidekamm, C. [AKH, Medizinische Universitaet Wien, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria)

    2012-02-15

    For optimal therapy management of patients with rheumatoid arthritis (RA) specific and sensitive diagnostic methods are essential for assessment of disease activity. In addition to projection radiography, imaging techniques, in particular magnetic resonance imaging (MRI) and ultrasound (US) are becoming increasingly more important for the early diagnosis of RA. The MRI and US techniques play a key role in the early imaging diagnostics of RA. Measurement of inflammation activity represents the basis of therapeutic decision-making and can be quantitatively and qualitatively determined with MRI and US. Synovitis and bone marrow edema are predictors of erosion. (orig.) [German] Fuer das optimale Therapiemanagement bei Patienten mit rheumatoider Arthritis (RA) sind spezifische und sensible diagnostische Methoden zur Beurteilung der Krankheitsaktivitaet unerlaesslich. Neben der Projektionsradiographie gewinnen die bildgebenden Methoden zur Fruehdiagnostik der RA, insbesondere die Magnetresonanztomographie (MRT) und der Ultraschall (US), zunehmend an Bedeutung. MRT und US spielen eine Schluesselrolle in der bildgebenden Fruehdiagnostik der RA. Die Messung der Entzuendungsaktivitaet stellt die Basis fuer die Therapieentscheidung dar. Sie kann mit dem US und der MRT quantitativ und semiquantitativ bestimmt werden. Synovialitis und Knochenmarkoedem sind Praediktoren fuer Erosionen. (orig.)

  12. Interreader agreement in the assessment of magnetic resonance images of rheumatoid arthritis wrist and finger joints--an international multicenter study

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Klarlund, Mette; Lassere, M;

    2001-01-01

    Magnetic resonance imaging (MRI) allows direct visualization of inflammation and destruction in rheumatoid arthritis (RA) joints. However, MRI scoring methods have not yet been standardized or appropriately validated. Our aim was to examine interreader agreement for a simple system of scoring RA ...

  13. Magnetic resonance imaging-determined synovial membrane and joint effusion volumes in rheumatoid arthritis and osteoarthritis: comparison with the macroscopic and microscopic appearance of the synovium

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Stoltenberg, M; Løvgreen-Nielsen, P;

    1997-01-01

    OBJECTIVE: To evaluate the relationship between synovial membrane and joint effusion volumes determined by magnetic resonance imaging (MRI) and macroscopic and microscopic synovial pathologic findings in patients with rheumatoid arthritis (RA) and osteoarthritis (OA). METHODS: Synovial biopsies...... membrane and effusion volumes may be sensitive markers and/or predictors of disease activity and treatment outcome in RA....

  14. A multireader reliability study comparing conventional high-field magnetic resonance imaging with extremity low-field MRI in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Bird, Paul; Ejbjerg, Bo; Lassere, Marissa;

    2007-01-01

    The use of extremity low-field magnetic resonance imaging (E-MRI) is increasing, but relatively few data exist on its reproducibility and accuracy in comparison with high-field MRI, especially for multiple readers. The aim of this multireader exercise of rheumatoid arthritis wrist and metacarpoph...

  15. OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Core set of MRI acquisitions, joint pathology definitions, and the OMERACT RA-MRI scoring system

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Peterfy, C; Conaghan, P;

    2003-01-01

    This article describes the 2002 OMERACT rheumatoid arthritis magnetic resonance image scoring system (RAMRIS) for evaluation of inflammatory and destructive changes in RA hands and wrists, which was developed by an international MRI-OMERACT group. MRI definitions of important RA joint pathologies......, and a 'core set' of basic MRI sequences for use in RA are also suggested...

  16. A multireader reliability study comparing conventional high-field magnetic resonance imaging with extremity low-field MRI in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Bird, Paul; Ejbjerg, Bo; Lassere, Marissa;

    2007-01-01

    The use of extremity low-field magnetic resonance imaging (E-MRI) is increasing, but relatively few data exist on its reproducibility and accuracy in comparison with high-field MRI, especially for multiple readers. The aim of this multireader exercise of rheumatoid arthritis wrist...

  17. Validation of the OMERACT Psoriatic Arthritis Magnetic Resonance Imaging Score (PsAMRIS) for the Hand and Foot in a Randomized Placebo-controlled Trial

    DEFF Research Database (Denmark)

    Glinatsi, Daniel; Bird, Paul; Gandjbakhch, Frederique;

    2015-01-01

    Objective. To assess changes following treatment and the reliability and responsiveness to change of the Outcome Measures in Rheumatology (OMERACT) Psoriatic Arthritis Magnetic Resonance Imaging Score (PsAMRIS) in a randomized controlled trial. Methods. Forty patients with PsA randomized to either...

  18. Magnetic resonance imaging, radiography, and scintigraphy of the finger joints: one year follow up of patients with early arthritis. The TIRA Group

    DEFF Research Database (Denmark)

    Klarlund, Mette; Østergaard, Mikkel; Jensen, K E;

    2000-01-01

    OBJECTIVES: To evaluate synovial membrane hypertrophy, tenosynovitis, and erosion development of the 2nd to 5th metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints by magnetic resonance imaging in a group of patients with rheumatoid arthritis (RA) or suspected RA followed up for one...

  19. OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Exercise 5: an international multicenter reliability study using computerized MRI erosion volume measurements

    DEFF Research Database (Denmark)

    Bird, P; Ejbjerg, B; McQueen, F;

    2003-01-01

    Scoring erosions on magnetic resonance imaging (MRI) is one method of estimating damage in patients with rheumatoid arthritis (RA), but it has limitations. The aim of this pilot study was to assess the feasibility and inter-reader reliability of computer assisted erosion volume estimation in...... patients with RA. Intra-reader and inter-occasion reliability was also assessed, and different slice thicknesses were compared in terms of erosion volume estimation. A 3 mm slice thickness 3D gradient-echo sequence followed by a 1 mm sequence was performed at baseline and repeated within 24 h with...... volume estimation method was more time consuming, taking roughly 5 times as long as the scoring method. Computerized MRI erosion volume measurements are feasible, with high intra-observer and inter-occasion reliabilities. Despite high ICC, the inter-observer reliability is not sufficient for multicenter...

  20. Differentiation between early rheumatoid arthritis patients and healthy persons by conventional and dynamic contrast-enhanced magnetic resonance imaging

    DEFF Research Database (Denmark)

    Axelsen, Mette Bjørndal; Ejbjerg, B J; Hetland, M L;

    2014-01-01

    OBJECTIVES: To identify the magnetic resonance imaging (MRI) parameter that best differentiates healthy persons and patients with early rheumatoid arthritis (RA), and to investigated responsiveness to treatment of various MRI parameters. METHOD: Conventional MRI and dynamic contrast-enhanced (DCE)-MRI...... of the hand were performed once for 26 healthy persons, and before and after 6 and 12 months of disease-modifying anti-rheumatic drug (DMARD) treatment for 14 early RA patients, using a 1.0-T MRI unit. One-slice DCE-MRI was analysed using Dynamika version 4.2. The number of enhancing voxels (Nvoxel......), the initial rate of enhancement (IRE), the maximum enhancement (ME), ME×Nvoxel, and IRE×Nvoxel were calculated for wrist and 2nd-5th metacarpophalangeal (MCP) joints. Conventional MR images were evaluated using the RA MRI scoring system (RAMRIS) synovitis score. RESULTS: Using DCE-MRI, enhancement...

  1. A multicenter reliability study of extremity-magnetic resonance imaging in the longitudinal evaluation of rheumatoid arthritis

    DEFF Research Database (Denmark)

    Conaghan, Philip G; Ejbjerg, Bo; Lassere, Marissa;

    2007-01-01

    scores using 0.2 T E-MRI hand and wrist images from 2 timepoints, evaluated by 3 readers at different international centers. The intraclass correlation coefficients and smallest detectable difference results for the change scores were generally good for erosions and synovitis, but were not acceptable for......There are limited data on the reliability of extremity magnetic resonance imaging (E-MRI) in the longitudinal evaluation of rheumatoid arthritis (RA). Our aim was to assess the interreader reliability of the OMERACT RA MRI score in the assessment of change in disease activity and bone erosion...... bone edema. Overall, E-MRI demonstrated ability to detect change comparable to that reported for high-field MRI for erosion and synovitis....

  2. Reliability and sensitivity to change of the OMERACT rheumatoid arthritis magnetic resonance imaging score in a multireader, longitudinal setting

    DEFF Research Database (Denmark)

    Haavardsholm, ea; Østergaard, Mikkel; Kvan, NP;

    2005-01-01

    OBJECTIVE: To assess the intra- and interreader reliability and the sensitivity to change of the Outcome Measures in Rheumatology Clinical Trials (OMERACT) Rheumatoid Arthritis Magnetic Resonance Imaging Score (RAMRIS) system on digital images of the wrist joints of patients with early...... acquired and scored according to the recommendations from the OMERACT MRI group. The intra- and interreader agreement (evaluated by intraclass correlation coefficients [ICCs]) and the sensitivity to change (evaluated by the smallest detectable difference [SDD]) were determined for scores of synovitis...... 0.74 for synovitis, 0.67 for erosion, and 0.95 for edema). The average-measure ICCs were > or =0.94 for all components of both the status scores and change scores. CONCLUSION: The RAMRIS showed very good intrareader reliability, good interreader reliability, and a high level of sensitivity to change...

  3. OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Exercise 3: an international multicenter reliability study using the RA-MRI Score

    DEFF Research Database (Denmark)

    Lassere, M; McQueen, F; Østergaard, Mikkel;

    2003-01-01

    We examined inter-reader agreement of the revised OMERACT 5 Rheumatoid Arthritis MRI Score (RAMRIS v3). Magnetic resonance (MR) images of 10 sets of metacarpophalangeal (MCP) joints 2-5 and 8 sets of rheumatoid arthritis (RA) wrists [1.5 T, coronal and axial T1 and T2 spin-echo, +/- fat saturation......ICC 0.58, avICC 0.89, %SDD +/- 27), wrist bone erosion scores (0.72, 0.94, +/- 31%), the wrist synovitis global (0.74, 0.94, +/- 32%), and synovial maximal thickness (0.6, 0.94, +/- 32%) met these conditions. MCP joint synovitis global (0.76, 0.95, +/-35%), MCP joint bone edema (0.63, 0.91, +/- 34......%), and wrist bone edema (0.78, 0.95, +/- 38%) performed marginally less well. Bone defects performed poorly (MCP joint 0.18, 0.46, +/- 56%; wrist 0.06, 0.24, +/- 55%). The revised OMERACT 5 RAMRIS has acceptable inter-reader reliability for measures of disease activity (synovitis global and bone edema...

  4. Low-cost, low-field dedicated extremity magnetic resonance imaging in early rheumatoid arthritis: a 1-year follow-up study

    DEFF Research Database (Denmark)

    Lindegaard, H.M.; Vallø, J.; Hørslev-Petersen, K.;

    2006-01-01

    OBJECTIVE: To study the ability of low-cost low-field dedicated extremity magnetic resonance imaging (E-MRI) to assess and predict erosive joint damage in the wrist and metacarpophalangeal (MCP) joints of patients with early rheumatoid arthritis. METHODS: 24 previously untreated patients with...... rheumatoid arthritis with joint symptoms for <1 year were evaluated at the time of diagnosis and after 6 and 12 months of methotrexate treatment with conventional clinical or biochemical examinations, x rays of both hands and wrists, and E-MRI of the dominant wrist and MCP joints. RESULTS: At baseline, all...... arthritis who were treated uniformly, baseline E-MRI erosions in MCP or wrist bones markedly increased the risk of x ray erosions at the 1-year follow-up. Low-cost, low-field dedicated extremity MRI is promising for assessment and prognostication of early rheumatoid arthritis. Udgivelsesdato: 2006-Sep...

  5. Ultrasonography and magnetic resonance imaging in early rheumatoid arthritis: recent advances

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Døhn, Uffe M; Ejbjerg, Bo J;

    2006-01-01

    Efficient methods for diagnosis, monitoring, and prognostication are essential in early rheumatoid arthritis. Data on the value of ultrasonography and MRI are accumulating rapidly, fueling their increasing use in early rheumatoid arthritis. This review focuses on recent advances in the clinical...

  6. Ultrasonography and magnetic resonance imaging in early rheumatoid arthritis: recent advances

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Døhn, Uffe M; Ejbjerg, Bo J;

    2006-01-01

    Efficient methods for diagnosis, monitoring, and prognostication are essential in early rheumatoid arthritis. Data on the value of ultrasonography and MRI are accumulating rapidly, fueling their increasing use in early rheumatoid arthritis. This review focuses on recent advances in the clinical a...... applications of these imaging modalities. Udgivelsesdato: 2006-Oct...

  7. Combination of 18F-fluorodeoxyglucose positron emission tomography/computed tomography and magnetic resonance imaging is an optimal way to evaluate rheumatoid arthritis in rats dynamically

    Institute of Scientific and Technical Information of China (English)

    ZHANG Wei-tao; DU Xiang-ke; HUO Tian-long; WEI Zheng-mao; HAO Chuan-xi; AN Bei

    2013-01-01

    Background Rheumatoid arthritis (RA) is a chronic,systemic autoimmune inflammatory disorder.Many methods have been used to observe the progress of RA.The purpose of this study was to observe the progress of RA in rats with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT),magnetic resonance (MR) imaging and arthritis score,and analyze the relationships among different methods in evaluation of RA.Methods Sixteen healthy Sprague Dawley (SD) rats about 8-week old were randomly assigned to a RA group and a control group.Bovine type Ⅱ emulsified incomplete Freud's adjuvant was used to induce arthritis in the RA group.Arthritis score of the rats in two groups were recorded,and 18F-FDG PET/CT,MR imaging were performed both on the corresponding rats every 3 days.All the rats were sacrificed at week 5,and histopathological examination was performed on rat knees stained with haematoxylin and eosin.Results The arthritis score and the standard uptake value (SUV) of knee joints in RA rats increased with the progression of arthritis gradually.Both peaks of arthritis score and SUV appeared at 21 days after the first immune injection,then the arthritis score and SUV of knee joints decreased slowly.The arthritis scores of knee joints in RA rats were positively correlated with their SUV changes.The MR images were confirmed by the histopathological studies.Conclusion PET/CT can detect the earliest molecular metabolism changes of RA,and MR imaging can follow up the dynamical anatomical changes of RA,all of which indicated that PET/CT and MR imaging may be applied as useful tools to monitor the progress of RA.

  8. Magnetic resonance imaging findings in 84 patients with early rheumatoid arthritis: bone marrow oedema predicts erosive progression

    DEFF Research Database (Denmark)

    Haavardsholm, Espen A; Bøyesen, Pernille; Ostergaard, Mikkel;

    2008-01-01

    consecutive patients with RA with disease duration <1 year were enrolled. Patients were treated according to standard clinical practice, and evaluated at baseline, 3, 6 and 12 months by core measures of disease activity, conventional radiographs of both hands and wrists and MRI of the dominant wrist. MR......Objectives: To examine the spectrum and severity of magnetic resonance imaging (MRI) findings in patients with early rheumatoid arthritis (RA), and to investigate the predictive value of MRI findings for subsequent development of conventional radiographic (CR) damage and MRI erosions. Methods: 84...... images were scored according to the OMERACT rheumatoid arthritis magnetic resonance imaging score (RAMRIS), and conventional radiographs according to the van der Heijde modified Sharp score. Results: MRI findings reflecting inflammation (synovitis, bone marrow oedema and tenosynovitis) decreased during...

  9. Secondary frozen shoulder following septic arthritis – An unusual complication of magnetic resonance arthrogram

    Directory of Open Access Journals (Sweden)

    Aysha Rajeev

    2015-01-01

    Conclusion: Septic arthritis is a recognised and rare complication of MR arthrogram. Early and prompt diagnosis with arthroscopic washout and debridement combined with intravenous antibiotics helps to eradicate the infection. Secondary frozen shoulder is a late complication of sepsis in the joint.

  10. Magnetic resonance imaging in the assessment of synovial inflammation of the hindfoot in patients with rheumatoid arthritis and other polyarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Maillefert, Jean Francis E-mail: jean-francis.maillefert@chu-dijon.fr; Dardel, Pascal; Cherasse, Anne; Mistrih, Rami; Krause, Denis; Tavernier, Christian

    2003-07-01

    Objectives: To describe the localisation of synovitis and tenosynovitis of the hindfoot observed on magnetic resonance imaging (MRI) in patients with chronic polyarthritis, and to correlate the findings of physical examination and MRI. Methods: Patients with chronic polyarthritis, and one or two painful hindfoot were included. On physical examination and on MRI, the tibio-talar, talo-calcaneal, and talo-navicular and calcaneo-cuboidal joints were adjudged to have or not synovitis, and the tibialis anterior and posterior, the peroneus longus and brevis, the flector digitorum and hallucis longus tendons to have or not tenosynovitis. Criteria for synovitis and tenosynovitis were a high signal intensity on T2-weighted images, a low signal intensity on T1-weighted images, and enhancement after Gd-DTPA injection, in the joint area, and around the tendon, respectively. The correlation between the findings of physical examination and those of MRI were evaluated using the Kappa statistics. Results: 12 patients (three men, nine women, mean age of 55.5 years{+-}11.4 S.D.) with chronic polyarthritis (rheumatoid arthritis (RA): nine, ankylosing spondylitis: one; psoriatic arthritis: one, unclassified: one) were included. All presented with one (7 patients) or two (5 patients) painful hindfeet (and swelling for 16 out of 17 hindfeet). On physical examination, 25 joints and eight tendons were adjudged to have synovitis and tenosynovitis. MRI showed synovitis in 12 out of 25 of these joints (48%), and tenosynovotis in three out of eight of these tendons (37.5%). Moreover, MRI showed ten and seven clinically unsuspected synovitis and tenosynovitis, respectively. The proportion of agreements between physical examination and MRI were 54.9% (kappa=0.1) and 88.2% (kappa=0.27) for synovitis and tenosynovitis, respectively. Conclusion: A weak correlation was observed between the findings of physical examination and MRI in patients with chronic polyarthritis and a painful hindfoot. MRI

  11. Are temporomandibular joint signs and symptoms associated with magnetic resonance imaging findings in juvenile idiopathic arthritis patients? A longitudinal study.

    Science.gov (United States)

    Zwir, Liete M L Figueiredo; Terreri, Maria Teresa R A; Sousa, Soraia Ale; Fernandes, Artur Rocha Corrêa; Guimarães, Antônio Sérgio; Hilário, Maria Odete E

    2015-12-01

    The aims of this longitudinal study were to perform a comprehensive clinical evaluation of temporomandibular joint (TMJ) and to investigate the association between the clinical and magnetic resonance imaging (MRI) findings in the TMJs of patients with juvenile idiopathic arthritis (JIA). Seventy-five patients with JIA participated in this study. All patients underwent a rheumatological examination performed by a paediatric rheumatologist, a TMJ examination performed by a single dentist and an MRI with contrast of the TMJs. These examinations were scheduled on the same date. The patients were examined again 1 year later. Twenty-eight (37.3 %) patients reported symptoms at the first evaluation and 11 (14.7 %) patients at the second evaluation. In relation to signs, 35 (46.7 %) of the patients presented at least one sign at the first evaluation and 29 (38.7 %) at the second. Intense contrast enhancement of TMJ was significantly associated with disease activity (p < 0.001) at the first evaluation and a trend to significance was observed at the second (p = 0.056), with poly/systemic subtypes (p = 0.028 and p = 0.049, respectively), with restricted mouth opening capacity (p = 0.013 and p = 0.001, respectively), with the presence of erosions at both evaluations (p = 0.0001 and p < 0.0001, respectively) and with altered condylar shape at the second evaluation (p = 0.0005). TMJ involvement is highly prevalent in JIA patients, with asymptomatic children presenting severe structural alterations of the TMJ. The TMJ should always be evaluated in JIA patients, even in the absence of signs and symptoms.

  12. MAGNETIC RESONANCE IMAGING OF THE SACROILIAC JOINT IN DIFFERENTIAL DIAGNOSIS OF EARLY POLYARTICULAR PSORIATIC AND RHEUMATOID ARTHRITIS (STUDY DATA REMARKA

    Directory of Open Access Journals (Sweden)

    Elena Yu Loginova

    2014-01-01

    Full Text Available Diagnosis of lesions of the spine and sacroiliac joints may be helpful in discrimination between early psoriatic arthritis (ePsA and early rheumatoid arthritis (eRA.Objective. To assess the significance of inflammatory back pain (IBP, HLA-B27, and active sacroiliitis (ASI confirmed by magnetic resonance imaging (MRI for differential diagnosis of polyarticular ePsA and eRA.Materials and Methods. The study included 29 patients with ePsA (13 males and 16 females, mean age 36.52 ± 11.27 years, average duration of the disease 13.03 ± 9.77 months and 25 patients with eRA (7 males and 18 females, mean age 52.68 ± 14.7 years, average duration of the disease 4.0 ± 1.72 months. Presence of IBP (according to the ASAS criteria and HLA-B27 were assessed (in 27 patients with PsA and in 20 patients with RA; ASI signs were assessed based on the MRI data (bone marrow edema/osteitis. DAS, DAS28, M ± SD, Fisher's exact test, t-test, χ2, the Yule coefficients of association (Q: level from -1 to +1 and Phi were calculated; differences were considered to be statistically significant at p <0.05.Results. In patients with ePsA, ASI was detected by MRI significantly more frequently than in patients with eRA (41.4% and 12% of cases respectively, p < 0.016. No correlation between the presence of ASI and DAS28 was observed in both groups. In the ePsA group, IBP was detected in 17 patients (58.6%; it was long-term in 10 (58.8% of the patients and episodic – in 7 (41.2% patients. Back pain with mechanical rhythm was observed in 3 (12% patients with eRA. HLA-B27 was detected in 9 (33.3% of 27 patients with ePsA and in 3 (15% of 20 patients with eRA (p < 0.014. In patients with ePsA, a very high level of association between ASI and IBP (Q = 0.91, Phi = 0.56; p < 0.003 and a high level of association between ASI and HLA-B27 (Q = 0.75, Phi = 0.56; p < 0.039 were detected. MRI showed no association between the presence of HLA-B27 and ASI signs in patients with RA

  13. New radiographic bone erosions in the wrists of patients with rheumatoid arthritis are detectable with magnetic resonance imaging a median of two years earlier

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Hansen, Michael; Stoltenberg, Michael;

    2003-01-01

    OBJECTIVE: In a 5-year followup study, we investigated the temporal relationship between development of wrist joint erosions as visualized by magnetic resonance imaging (MRI) versus conventional radiography (CR), in patients with rheumatoid arthritis. We also evaluated the risk of erosive...... progression on CR associated with the presence of MRI erosions. METHODS: In 10 patients with rheumatoid arthritis, MRI and CR of the dominant wrist were performed annually for 5 years. In each image set, each wrist bone (metacarpal bases, carpal bones, radius, and ulna) was assessed for the absence or...... presence of bone erosions. RESULTS: Nine bones showed radiographic erosions at baseline. Twenty-seven new radiographic erosions developed during the 5-year followup period. Of these 27 new erosions, 21 were detected 1-5 years earlier by MRI than by CR, 3 were simultaneously detected by both methods, 2 were...

  14. Magnetic resonance imaging of the hip in rheumatoid arthritis patients: a descriptive study; A ressonancia magnetica do quadril na avaliacao de pacientes com artrite reumatoide: estudo descritivo

    Energy Technology Data Exchange (ETDEWEB)

    Caldana, Wanda Chiyoko Iwakami; Fernandes, Artur da Rocha Correa [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. de Diagnostico por Imagem]. E-mail: wiwakami@ig.com.br; Ciconelli, Rozana Mesquita [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil); Juliano, Yara [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. de Epidemiologia e Bioestatistica

    2005-07-15

    Objective: To assess the usefulness of MRI as a diagnostic method in patients with rheumatoid arthritis, and to evaluate the frequency of changes in the hip in symptomatic and asymptomatic patients. Materials and methods: Forty patients (17 symptomatic and 23 asymptomatic) were evaluated by 1.5 T magnetic resonance imaging (MRI) after intravenous contrast media injection. MRI findings were divided in inflammatory, degenerative, combined (inflammatory and degenerative) and extra-articular changes. Results: The most frequent findings seen were degenerative and extra-articular changes (22.5% each). Inflammatory changes were seen in only five (12.5%) symptomatic patients, four of them with degenerative findings associated (10%). Conclusion: The use of MRI of the hip allowed the evaluation of the main articular abnormalities seen in patients with rheumatoid arthritis. The most frequent findings were degenerative and extra-articular changes. Inflammatory findings were seen in only five patients, four of them with degenerative changes associated. (author)

  15. Magnetic resonance imaging findings in 84 patients with early rheumatoid arthritis: bone marrow oedema predicts erosive progression

    DEFF Research Database (Denmark)

    Haavardsholm, Espen A; Bøyesen, Pernille; Ostergaard, Mikkel;

    2008-01-01

    images were scored according to the OMERACT rheumatoid arthritis magnetic resonance imaging score (RAMRIS), and conventional radiographs according to the van der Heijde modified Sharp score. Results: MRI findings reflecting inflammation (synovitis, bone marrow oedema and tenosynovitis) decreased during...... (odds ratio = 2.77 (95% confidence interval (CI) 1.06 to 7.21)) and MRI erosive progression (B = 0.21 (95% CI 0.08 to 0.34)). Conclusions: MRI findings were common in early RA, and MRI bone marrow oedema was an independent predictor of radiographic damage. These results suggest that MRI scans...

  16. Power Doppler ultrasonography for assessment of synovitis in the metacarpophalangeal joints of patients with rheumatoid arthritis: a comparison with dynamic magnetic resonance imaging

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, M; Strandberg, C;

    2001-01-01

    OBJECTIVE: To evaluate the effectiveness of power Doppler ultrasonography (PDUS) for assessing inflammatory activity in the metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA), using dynamic magnetic resonance imaging (MRI) as a reference method. METHODS: PDUS and dynamic...... MRI were performed on 54 MCP joints of 15 patients with active RA and on 12 MCP joints of 3 healthy controls. PDUS was performed with a LOGIQ 500 unit by means of a 7-13-MHz linear array transducer. Later the same day, MRI was performed with a 1.0T MR unit. A series of 24 coronal T1-weighted images...

  17. Imagens de ressonância magnética na artrite reumatoide Magnetic resonance imaging in rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Wilson Campos Tavares Junior

    2011-12-01

    Full Text Available A artrite reumatoide (AR é uma poliartrite inflamatória crônica que frequentemente causa progressiva destruição articular. O tratamento e o manejo da AR têm se baseado na identificação e na intervenção precoce da doença com medicamentos modificadores da doença (DMARDs. As alterações no tratamento têm resultado em melhora significativa para os pacientes, incluindo redução dos sintomas e dos sinais da doença, preservação articular e redução da progressão de lesões. Métodos de avaliação de resposta ao tratamento e predição do curso da doença são necessários. Em relação ao diagnóstico precoce da AR, estudos longitudinais demonstraram que a imagem por ressonância magnética (IRM é mais sensível que a radiografia (RX para demonstrar presença e progressão de erosões ósseas. Por outro lado, muitos fatores de pior prognóstico têm sido relacionados à AR, incluindo fatores demográficos, genéticos, clínicos, imunológicos e radiográficos. Este artigo apresenta a IRM na AR em relação ao seu valor no diagnóstico, no monitoramento e no prognóstico da doença.Rheumatoid arthritis (RA is a chronic inflammatory polyarthritis that often leads to progressive joint destruction and disability. The treatment and management of RA has been based on early identification of the disease and intervention with disease-modifying antirheumatic drugs (DMARDs. Changes in management have resulted in significant improvements for patients with RA, including reduction of signs and symptoms of disease, joint preservation, and reduction of structural damage progression. In addition, sensitive methods to assess treatment response and predict the course of disease are required. Regarding early diagnosis of RA, longitudinal studies have demonstrated that magnetic resonance imaging (MRI is more sensitive than X-rays to demonstrate the presence and progression of bone erosions. On the other hand, many factors of poor prognostics have

  18. Validity of ultrasonography and measures of adult shoulder function and reliability of ultrasonography in detecting shoulder synovitis in patients with rheumatoid arthritis using magnetic resonance imaging as a gold standard.

    LENUS (Irish Health Repository)

    Bruyn, G A W

    2010-08-01

    To assess the intra- and interobserver reproducibility of musculoskeletal ultrasonography (US) in detecting inflammatory shoulder changes in patients with rheumatoid arthritis, and to determine the agreement between US and the Shoulder Pain and Disability Index (SPADI) and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire, using magnetic resonance imaging (MRI) as a gold standard.

  19. Magnetic resonance imaging of wrist and finger joints in healthy subjects occasionally shows changes resembling erosions and synovitis as seen in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Ejbjerg, Bo; Narvestad, Eva; Rostrup, Egill;

    2004-01-01

    OBJECTIVE: To explore the presence of changes resembling rheumatoid arthritis erosions and synovitis in metacarpophalangeal (MCP) and wrist joints of healthy individuals on magnetic resonance imaging (MRI) and to compare the MRI findings with conventional radiographic, clinical, and biochemical...... findings. METHODS: Twenty-eight healthy individuals were studied. Contrast-enhanced MRI and conventional radiography of the dominant wrist and second through fifth MCP joints were performed, coupled with standard clinical assessments and biochemical analyses. MR images were evaluated according to the...... latest OMERACT (Outcome Measures in Rheumatology Clinical Trials) recommendations with respect to synovitis, erosions, and bone marrow edema. RESULTS: Conventional radiography revealed erosion-like changes in 1 of 224 MCP joint bones (0.4%) and in 1 of 420 wrist joint bones (0.2%). MRI depicted low...

  20. Dynamic gadolinium-enhanced magnetic resonance imaging allows accurate assessment of the synovial inflammatory activity in rheumatoid arthritis knee joints: a comparison with synovial histology

    DEFF Research Database (Denmark)

    Axelsen, Mette Bjørndal; Stoltenberg, M.; Poggenborg, R.;

    2012-01-01

    Objective: To determine whether dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) evaluated using semi-automatic image processing software can accurately assess synovial inflammation in rheumatoid arthritis (RA) knee joints. Methods: In 17 RA patients undergoing knee surgery...... capsule of the knee joint (Precise ROI). Intra- and interreader agreement was assessed using the intra-class correlation coefficient (ICC). Results: The IRE from the Quick ROI and the Precise ROI revealed high correlations to the grade of histological inflammation (Spearman's correlation coefficient (rho...... (IRE), were generated by the software in three different areas: (I) the entire slice (Whole slice); (II) a manually outlined region of interest (ROI) drawn quickly around the joint, omitting large artefacts such as blood vessels (Quick ROI); and (III) a manually outlined ROI following the synovial...

  1. Comparison of magnetic resonance imaging signs and clinical findings in follow-up examinations in children and juveniles with temporomandibular joint involvement in juvenile idiopathic arthritis

    International Nuclear Information System (INIS)

    The aim of this study was to analyze the extent to which pathological findings of temporomandibular joint (TMJ) in magnetic resonance imaging (MRI) follow-up examinations are correlated with clinical symptoms in patients with TMJ involvement in juvenile ideopathic arthritis (JIA) over time. Data from 34 patients with TMJ involvement in JIA was retrospectively examined. Shortly after two clinical examinations, the first MRI and the follow-up MRI were performed. The MRI examinations took place with 1.5 T MRI. In both MRI examinations alterations on the condyle (MRI1: 88 %, MRT2: 91 %) and contrast enhancement (MRT1: 76 %, MRT2 65 %) were found most frequently. TMJ pain (65 %) and lower mouth opening capacity (65 %) were the number one finding in the first clinical examination. A statistically significant correlation was found between the alterations on the condyle and TMJ pain (p = 0.025) and between the alterations on the condyle and lower mouth opening capacity (p = 0.019). By comparing the results of the first MRI with the results of the follow-up MRI, we identified a trend towards a progression of TMJ arthritis, while the clinical follow-up showed an improvement in most patients. We found a discrepancy between the progressive or stable trends of pathological findings in follow-up MRI and the decrease in clinical symptoms over time. Therefore, follow-up examination by MRI shows important information for correct evaluation about the stage of TMJ arthritis and about the need for treatment. Consequently, follow-up examination by MRI is an appropriate addition to clinical examination in the therapeutic concept. (orig.)

  2. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options ... 8 MB) Also available in Other Language versions . Magnetic Resonance Imaging (MRI) is a medical imaging procedure for making ...

  3. Magnetic resonance angiography

    Science.gov (United States)

    MRA; Angiography - magnetic resonance ... Kwong RY. Cardiovascular Magnetic Resonance Imaging. In: Bonow RO, Mann DL, Zipes DP, Libby P, eds. Braunwald's Heart Disease: A Textbook of Cardiovascular Medicine . ...

  4. [The temporomandibular joint in juvenile idiopathic arthritis: what radiologists need to look for on magnetic resonance imaging].

    Science.gov (United States)

    De La Hoz Polo, M; Navallas, M

    2014-01-01

    The term "juvenile idiopathic arthritis" (JIA) encompasses a group of arthritis of unknown cause with onset before the age of 16 years that last for at least 6 weeks. The prevalence of temporomandibular joint involvement in published series ranges from 17% to 87%. Temporomandibular joint involvement is difficult to detect clinically, so imaging plays a key role in diagnosis and monitoring treatment. MRI is the technique of choice for the study of arthritis of the temporomandibular joint because it is the most sensitive technique for detecting acute synovitis and bone edema. Power Doppler ultrasonography can also detect active synovitis by showing the hypervascularization of the inflamed synovial membrane, but it cannot identify bone edema. This article describes the MRI technique for evaluating the temporomandibular joint in patients with juvenile idiopathic arthritis, defines the parameters to look for, and illustrates the main findings.

  5. Magnetic resonance imaging-determined synovial membrane volume as a marker of disease activity and a predictor of progressive joint destruction in the wrists of patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Hansen, M; Stoltenberg, M;

    1999-01-01

    OBJECTIVE: To evaluate the synovial membrane volume, determined by magnetic resonance imaging (MRI), as a marker of joint disease activity and a predictor of progressive joint destruction in rheumatoid arthritis (RA). METHODS: Twenty-six patients with RA, randomized to receive disease-modifying a......OBJECTIVE: To evaluate the synovial membrane volume, determined by magnetic resonance imaging (MRI), as a marker of joint disease activity and a predictor of progressive joint destruction in rheumatoid arthritis (RA). METHODS: Twenty-six patients with RA, randomized to receive disease......-Pratt analysis). The rate of erosive progression on MRI was highly correlated with baseline scores and, particularly, with area under the curve (AUC) values of synovial membrane volume (Spearman's sigma = 0.69, P < 0.001), but not with baseline or AUC values of local or global clinical or biochemical parameters...

  6. Feasibility of diffusion-weighted magnetic resonance imaging in patients with juvenile idiopathic arthritis on 1.0-T open-bore MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barendregt, Anouk M.; Nusman, Charlotte M. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Hemke, Robert; Lavini, Cristina; Maas, Mario [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Amiras, Dimitri [Imperial College Healthcare NHS Trust, Radiology Department, St. Mary' s Hospital, Paddington, London (United Kingdom); Kuijpers, Taco W. [University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands)

    2015-12-15

    To evaluate the feasibility of non-invasive diffusion-weighted imaging (DWI) of the knee of children with juvenile idiopathic arthritis (JIA) and, further, to analyze the apparent diffusion coefficient (ADC) levels to distinguish synovium from effusion. Standard magnetic resonance imaging of the knee including post-contrast imaging was obtained in eight patients (mean age, 12 years 8 months, five females) using an open-bore magnetic resonance imaging system (1.0 T). In addition, axially acquired echo-planar DWI datasets (b-values 0, 50, and 600) were prospectively obtained and the diffusion images were post-processed into ADC{sub 50-600} maps. Two independent observers selected a region of interest (ROI) for both synovium and effusion using aligned post-contrast images as landmarks. Mann-Whitney U test was performed to compare ADC synovium and ADC effusion. DWI was successfully obtained in all patients. When data of both observers was combined, ADC synovium was lower than ADC effusion in the ROI in seven out of eight patients (median, 1.92 x 10{sup -3} mm{sup 2}/s vs. 2.40 x 10{sup -3} mm{sup 2}/s, p = 0.006, respectively). Similar results were obtained when the two observers were analyzed separately (observer 1: p = 0.006, observer 2: p = 0.04). In this pilot study, on a patient-friendly 1.0-T open-bore MRI, we demonstrated that DWI may potentially be a feasible non-invasive imaging technique in children with JIA. We could differentiate synovium from effusion in seven out of eight patients based on the ADC of synovium and effusion. However, to select synovium and effusion on DWI, post-contrast images were still a necessity. (orig.)

  7. Feasibility of diffusion-weighted magnetic resonance imaging in patients with juvenile idiopathic arthritis on 1.0-T open-bore MRI

    International Nuclear Information System (INIS)

    To evaluate the feasibility of non-invasive diffusion-weighted imaging (DWI) of the knee of children with juvenile idiopathic arthritis (JIA) and, further, to analyze the apparent diffusion coefficient (ADC) levels to distinguish synovium from effusion. Standard magnetic resonance imaging of the knee including post-contrast imaging was obtained in eight patients (mean age, 12 years 8 months, five females) using an open-bore magnetic resonance imaging system (1.0 T). In addition, axially acquired echo-planar DWI datasets (b-values 0, 50, and 600) were prospectively obtained and the diffusion images were post-processed into ADC50-600 maps. Two independent observers selected a region of interest (ROI) for both synovium and effusion using aligned post-contrast images as landmarks. Mann-Whitney U test was performed to compare ADC synovium and ADC effusion. DWI was successfully obtained in all patients. When data of both observers was combined, ADC synovium was lower than ADC effusion in the ROI in seven out of eight patients (median, 1.92 x 10-3 mm2/s vs. 2.40 x 10-3 mm2/s, p = 0.006, respectively). Similar results were obtained when the two observers were analyzed separately (observer 1: p = 0.006, observer 2: p = 0.04). In this pilot study, on a patient-friendly 1.0-T open-bore MRI, we demonstrated that DWI may potentially be a feasible non-invasive imaging technique in children with JIA. We could differentiate synovium from effusion in seven out of eight patients based on the ADC of synovium and effusion. However, to select synovium and effusion on DWI, post-contrast images were still a necessity. (orig.)

  8. Monitoring anti-interleukin 6 receptor antibody treatment for rheumatoid arthritis by quantitative magnetic resonance imaging of the hand and power Doppler ultrasonography of the finger

    Energy Technology Data Exchange (ETDEWEB)

    Kamishima, Tamotsu; Terae, Satoshi [Hokkaido University Hospital, Department of Radiology, Sapporo (Japan); Tanimura, Kazuhide; Shimizu, Masato; Matsuhashi, Megumi; Fukae, Jun; Hagiwara, Hiromi; Narita, Akihiro; Aoki, Yuko [Hokkaido Medical Center for Rheumatic Diseases, Sapporo (Japan); Kon, Yujiro [St Thomas' Hospital, London (United Kingdom); Kosaka, Naoki [Tokeidai Memorial Hospital, Sapporo (Japan); Atsumi, Tatsuya [Hokkaido University Graduate School of Medicine, Department of Medicine, Sapporo (Japan); Shirato, Hiroki [Hokkaido University Graduate School of Medicine, Department of Radiology, Sapporo (Japan)

    2011-06-15

    To compare quantitative magnetic resonance imaging (MRI) and power Doppler ultrasonography (PDUS) with conventional measures of disease activity in rheumatoid arthritis (RA) patients treated with the anti-interleukin 6 (anti-IL 6) receptor antibody tocilizumab in terms of responsiveness at a few months to disease activity and ability to predict structural damage at 1 year. A cohort of patients with RA (n = 29) was evaluated clinically including disease activity score 28 (DAS28) and by semiquantitative (SQ-) and quantitative (Q-) PDUS (bilateral metacarpophalangeal joints) and MRI (one hand and wrist) at initiation of treatment with anti-IL 6 receptor antibody agents and after 2 and 5 months. Conventional radiography for both hands and wrists was performed at baseline and at 12 months. Responsiveness was assessed by standardized response means (SRM). Areas under the curve (AUC) for measures at baseline, 2 and 5 months were correlated with structural damage at 1 year. Among the laboratory and clinical parameters, DAS28-ESR was the most responsive with a large effect size of SRM. Structural damage progressions for radiography and MR erosion were correlated with AUC of MR bone erosion and Q-PDUS, respectively. In the evaluation of disease activity in RA patients in the first few months after starting anti-IL 6 receptor antibody tocilizumab treatment, the semiquantitative MR bone erosion score of the hand and quantitative value for power Doppler signal in the finger joint were both responsive and predictive of structural damage progression at 1 year. (orig.)

  9. Interreader agreement in the assessment of magnetic resonance images of rheumatoid arthritis wrist and finger joints--an international multicenter study

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Klarlund, Mette; Lassere, M;

    2001-01-01

    Magnetic resonance imaging (MRI) allows direct visualization of inflammation and destruction in rheumatoid arthritis (RA) joints. However, MRI scoring methods have not yet been standardized or appropriately validated. Our aim was to examine interreader agreement for a simple system of scoring RA...... spin-echo, -/+ fat saturation (FS), -/+ iv gadolinium (Gd)] were scored for synovitis (score 0-3) and bone lesions (0-3). In substudy 2, we evaluated 19 sets of 2nd-5th MCP joints [10 sets from UK (Technique A) and 9 sets from the US (Technique B: 1.5 T; coronal T1 spin-echo and T2* gradient-echo + FS......, no Gd)] and 19 wrist joints [9 from the US (Technique B) and 10 from Denmark (Technique C: 1.0 T; coronal and axial T1 spin-echo, no FS, -/+ Gd)]. Synovitis (0-3), bone lesions (0-3), and joint space narrowing (JSN, 0-3) were scored in each MCP joint and in 3 different regions of the wrist. Bone...

  10. Magnetic Resonance Imaging (MRI)

    Science.gov (United States)

    ... How Can I Help a Friend Who Cuts? Magnetic Resonance Imaging (MRI) KidsHealth > For Teens > Magnetic Resonance Imaging (MRI) Print A A A Text Size What's ... Exam Safety Getting Your Results What Is MRI? Magnetic resonance imaging (MRI) is a type of safe, painless testing ...

  11. Quantification of synovitis in the cranio-cervical region: Dynamic contrast enhanced and diffusion weighted magnetic resonance imaging in early rheumatoid arthritis-A feasibility follow up study

    Energy Technology Data Exchange (ETDEWEB)

    Jeromel, M., E-mail: miran.jeromel@gmail.com [Institute of Radiology, Department for Neuroradiology, University Medical Centre Ljubljana, Zaloska cesta 2, 1000 Ljubljana (Slovenia); Jevtic, V., E-mail: vladimir.jevtic@mf.uni-lj.si [Medical Faculty Ljubljana, Vrazov trg 2, 1104 Ljubljana (Slovenia); Sersa, I., E-mail: igor.sersa@ijs.si [Jozef Stefan Institute, Jamova cesta 39, 1000 Ljubljana (Slovenia); Ambrozic, A., E-mail: ales.ambrozic@mf.uni-lj.si [Department of Rheumatology, University Medical Centre Ljubljana, Vodnikova 62, 1000 Ljubljana (Slovenia); Tomsic, M., E-mail: matija.tomsic@kclj.si [Department of Rheumatology, University Medical Centre Ljubljana, Vodnikova 62, 1000 Ljubljana (Slovenia)

    2012-11-15

    Objective: To test the feasibility of dynamic contrast enhanced (DCEI) and diffusion weighted (DWI) magnetic resonance imaging (MRI) for quantifying synovitis of the cranio-cervical (C-C) region in patients with early rheumatoid arthritis (RA) and neck pain at the beginning and at a six month follow up. Methods: 27 patients with duration of RA of less than 24 months and neck pain were studied with standard qualitative MRI evaluation and two quantitative MRI methods (DCEI and DWI) at the level of atlantoaxial joints. Rate of early enhancement (REE), enhancement gradient (Genh) and apparent diffusion coefficient (ADC) were extracted from DCEI and DWI data. MRI was coupled with clinical assessment and radiographic imaging. Results: Using standard qualitative MRI evaluation, unequivocal active synovitis (grade 2 or 3 contrast enhancement) was proved in 16 (59%) patients at baseline and 14 (54%) at follow up. DCEI and DWI measurements confirmed active synovitis in 25 (93%) patients at baseline and 24 (92%) at follow up. Average REE, Genh and ADC values decreased during follow up, however the difference was not statistically significant (p > 0.05). Both qualitative and quantitative MRI methods confirmed active inflammatory disease in the C-C region following therapy although all clinical criteria showed signs of improvement of the peripheral disease. Conclusions: The study proved the feasibility of DCEI and DWI MRI for quantifying synovitis of the C-C region in patients with early RA and neck pain. Both techniques can be used as additional method for evaluation of synovitis of the C-C region in RA.

  12. Assessment of aortic stiffness among patients with systemic lupus erythematosus and rheumatoid arthritis by magnetic resonance imaging.

    Science.gov (United States)

    Karp, Galia; Wolak, Arik; Baumfeld, Yael; Bar-Am, Nina; Novack, Victor; Wolak, Talya; Fuchs, Lior; Shalev, Aryeh; Shelef, Ilan; Abu-Shakra, Mahmoud

    2016-06-01

    To evaluate aortic stiffness by MRI in female patients with systemic lupus erythematosus (SLE) or rheumatoid arthritis (RA) in comparison to controls. We measured aortic strain, distensibility and pulse wave velocity (PWV) by MRI in 30 SLE patients, 31 RA patients and 53 matched controls. Mean PWV in SLE and RA patients were higher in comparison to controls (9.2 ± 4.4 vs. 7.6 ± 3.0 m/s, p = 0.04) and (6.2 ± 2.3 vs. 5.4 ± 1.7, p = 0.04) respectively. Aortic distensibility among RA patients was significantly lower in comparison to controls (4.4 ± 4.6 vs. 5.8 ± 4.9 kPa(-1) × 10(-3), p = 0.04). A significant correlation was found between PWV and age (r = 0.67, p < 0.001), Framingham risk score (r = 0.61, p < 0.001), waist to hip ratio (r = 0.45, p < 0.001), systolic blood pressure (r = 0.37, p = 0.01), diabetes (r = 0.32, p = 0.001) and dyslipidemia (r = 0.32, p = 0.001). In multivariate analysis for the prediction of PWV, variables which were found significant included: RA (p = 0.01), age (p < 0.001) and hypertension (p = 0.01) for patients with RA and SLE (p = 0.02), waist to hip ratio (p < 0.001) and total cholesterol (p < 0.001) for patients with SLE. Arterial stiffness, characterized by metrics of aortic distensibility and pulse wave velocity derived from MRI, is increased in SLE and RA female patients.

  13. Reducing invasiveness, duration, and cost of magnetic resonance imaging in rheumatoid arthritis by omitting intravenous contrast injection -- Does it change the assessment of inflammatory and destructive joint changes by the OMERACT RAMRIS?

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Ostergaard, Mikkel; Conaghan, Philip G;

    2009-01-01

    OBJECTIVE: Gadolinium (Gd)-enhanced magnetic resonance imaging (MRI) provides highly sensitive assessment of inflammatory and destructive changes in rheumatoid arthritis (RA) joints, but intravenous (IV) Gd injection prolongs examination time and increases cost, invasiveness, and patient discomfort...... to high agreement concerning assessment of synovitis, and omitting the post-Gd acquisitions increased the interreader variation on synovitis scores. Low-field (0.2 T) E-MRI in these exercises provided a lower sensitivity of unenhanced imaging for synovitis than MRI using higher-field strengths. CONCLUSION...

  14. Magnetic Resonance Imaging and Magnetic Resonance Spectroscopy in Dementias

    OpenAIRE

    Hsu, Yuan-Yu; Du, An-Tao; Schuff, Norbert; Weiner, Michael W.

    2001-01-01

    This article reviews recent studies of magnetic resonance imaging and magnetic resonance spectroscopy in dementia, including Alzheimer's disease, frontotemporal dementia, dementia with Lewy bodies, idiopathic Parkinson's disease, Huntington's disease, and vascular dementia. Magnetic resonance imaging and magnetic resonance spectroscopy can detect structural alteration and biochemical abnormalities in the brain of demented subjects and may help in the differential diagnosis and early detection...

  15. Magnetic resonance imaging of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Mink, J.H.; Reicher, M.A.; Crues, J.V.

    1987-01-01

    Introducing a comprehensive, practical guide to the use of magnetic resonance imaging (MRI) in detecting and evaluating knee disorders and planning arthroscopic surgery) This book integrates MRI findings with pertinent anatomy, physiology, and clinical signs to assist radiologists in selecting imaging protocols and interpreting scans. Detailed chapters focus on magnetic resonance imaging of the menisci and ligaments and evaluation of osteonecrosis, osteochondrosis, and osteochondritis. The authors demonstrate the potential of MRI for diagnosing various knee disorders such as arthritis, fractures, popliteal cysts, synovial disease, plicae, popliteal artery aneurysms, tumors, and bone marrow disorders.

  16. Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Robert H. Morris

    2014-11-01

    Full Text Available Magnetic Resonance finds countless applications, from spectroscopy to imaging, routinely in almost all research and medical institutions across the globe. It is also becoming more frequently used for specific applications in which the whole instrument and system is designed for a dedicated application. With beginnings in borehole logging for the petro-chemical industry Magnetic Resonance sensors have been applied to fields as varied as online process monitoring for food manufacture and medical point of care diagnostics. This great diversity is seeing exciting developments in magnetic resonance sensing technology published in application specific journals where they are often not seen by the wider sensor community. It is clear that there is enormous interest in magnetic resonance sensors which represents a significant growth area. The aim of this special edition of Sensors was to address the wide distribution of relevant articles by providing a forum to disseminate cutting edge research in this field in a single open source publication.[...

  17. Dynamic contrast-enhanced magnetic resonance imaging of articular and extraarticular synovial structures of the hands in patients with psoriatic arthritis

    DEFF Research Database (Denmark)

    Cimmino, Marco Amedeo; Barbieri, Francesca; Boesen, Mikael;

    2012-01-01

    Dynamic, contrast-enhanced magnetic resonance imaging (DCE-MRI), the quantification of enhancement within the synovial membrane and bone by extracting curves using fast T1-weighted sequences during intravenous administration of contrast agent, evaluates synovitis and bone marrow edema in psoriatic...

  18. Efficient isotropic magnetic resonators

    OpenAIRE

    Martin, O. J. F.; Gay-Balmaz, P.

    2002-01-01

    We study experimentally and numerically a novel three-dimensional magnetic resonator structure with high isotropy. It is formed by crossed split-ring resonators and has a response independent of the illumination direction in a specific plane. The utilization of such elements to build a finite left-handed medium is discussed. (C) 2002 American Institute of Physics.

  19. Change in CD3 positive T-cell expression in psoriatic arthritis synovium correlates with change in DAS28 and magnetic resonance imaging synovitis scores following initiation of biologic therapy--a single centre, open-label study.

    LENUS (Irish Health Repository)

    Pontifex, Eliza K

    2011-01-01

    With the development of increasing numbers of potential therapeutic agents in inflammatory disease comes the need for effective biomarkers to help screen for drug efficacy and optimal dosing regimens early in the clinical trial process. This need has been recognized by the Outcome Measures in Rheumatology Clinical Trials (OMERACT) group, which has established guidelines for biomarker validation. To seek a candidate synovial biomarker of treatment response in psoriatic arthritis (PsA), we determined whether changes in immunohistochemical markers of synovial inflammation correlate with changes in disease activity scores assessing 28 joints (ΔDAS28) or magnetic resonance imaging synovitis scores (ΔMRI) in patients with PsA treated with a biologic agent.

  20. Magnetic resonance imaging-determined synovial membrane volume as a marker of disease activity and a predictor of progressive joint destruction in the wrists of patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Hansen, M; Stoltenberg, M;

    1999-01-01

    -modifying antirheumatic drug (DMARD) therapy alone (11 patients) or DMARDs in combination with oral prednisolone (15 patients), were followed up for 1 year with contrast-enhanced MRI of the dominant wrist (months 0, 3, 6, and 12), conventional radiography (months 0 and 12), and clinical and biochemical examinations. Bone......, or with prednisolone treatment. In none of 5 wrists with baseline volumes <5 cm3, but in 8 of 10 wrists with baseline volumes > or =10 cm3, erosive progression was found by MRI and/or radiography, indicating a predictive value of synovial membrane volumes. MRI was more sensitive than radiography for......OBJECTIVE: To evaluate the synovial membrane volume, determined by magnetic resonance imaging (MRI), as a marker of joint disease activity and a predictor of progressive joint destruction in rheumatoid arthritis (RA). METHODS: Twenty-six patients with RA, randomized to receive disease...

  1. Advances in magnetic resonance 10

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 10, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters that examine superoperators in magnetic resonance; ultrasonically modulated paramagnetic resonance; and the utility of electron paramagnetic resonance (EPR) and electron-nuclear double-resonance (ENDOR) techniques for studying low-frequency modes of atomic fluctuations and their significance for understanding the mechanism of structural phase transitions in solids.

  2. Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  3. Single spin magnetic resonance

    Science.gov (United States)

    Wrachtrup, Jörg; Finkler, Amit

    2016-08-01

    Different approaches have improved the sensitivity of either electron or nuclear magnetic resonance to the single spin level. For optical detection it has essentially become routine to observe a single electron spin or nuclear spin. Typically, the systems in use are carefully designed to allow for single spin detection and manipulation, and of those systems, diamond spin defects rank very high, being so robust that they can be addressed, read out and coherently controlled even under ambient conditions and in a versatile set of nanostructures. This renders them as a new type of sensor, which has been shown to detect single electron and nuclear spins among other quantities like force, pressure and temperature. Adapting pulse sequences from classic NMR and EPR, and combined with high resolution optical microscopy, proximity to the target sample and nanoscale size, the diamond sensors have the potential to constitute a new class of magnetic resonance detectors with single spin sensitivity. As diamond sensors can be operated under ambient conditions, they offer potential application across a multitude of disciplines. Here we review the different existing techniques for magnetic resonance, with a focus on diamond defect spin sensors, showing their potential as versatile sensors for ultra-sensitive magnetic resonance with nanoscale spatial resolution.

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) ... conditions such as: brain tumors stroke infections developmental anomalies hydrocephalus — dilatation of fluid spaces within the brain ( ...

  5. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how does ... What is MRI and how does it work? Magnetic resonance imaging, or MRI, is a way of obtaining very ...

  6. Resonant magnetic vortices

    International Nuclear Information System (INIS)

    By using the complex angular momentum method, we provide a semiclassical analysis of electron scattering by a magnetic vortex of Aharonov-Bohm type. Regge poles of the S matrix are associated with surface waves orbiting around the vortex and supported by a magnetic field discontinuity. Rapid variations of sharp characteristic shapes can be observed on scattering cross sections. They correspond to quasibound states which are Breit-Wigner-type resonances associated with surface waves and which can be considered as quantum analogues of acoustic whispering-gallery modes. Such a resonant magnetic vortex could provide a different kind of artificial atom while the semiclassical approach developed here could be profitably extended in various areas of the physics of vortices

  7. Magnetic resonance of phase transitions

    CERN Document Server

    Owens, Frank J; Farach, Horacio A

    1979-01-01

    Magnetic Resonance of Phase Transitions shows how the effects of phase transitions are manifested in the magnetic resonance data. The book discusses the basic concepts of structural phase and magnetic resonance; various types of magnetic resonances and their underlying principles; and the radiofrequency methods of nuclear magnetic resonance. The text also describes quadrupole methods; the microwave technique of electron spin resonance; and the Mössbauer effect. Phase transitions in various systems such as fluids, liquid crystals, and crystals, including paramagnets and ferroelectrics, are also

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head ... limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  11. Ultrasonography of the metacarpophalangeal and proximal interphalangeal joints in rheumatoid arthritis: a comparison with magnetic resonance imaging, conventional radiography and clinical examination

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Klarlund, Mette; Narvestad, E.;

    2006-01-01

    .96, respectively; they were 0.42, 0.99 and 0.95 for radiography. The sensitivity, specificity and accuracy of ultrasonography, with signs of inflammation on T1-weighted MRI sequences as the reference method, were 0.70, 0.78 and 0.76, respectively; they were 0.40, 0.85 and 0.72 for the clinical examination. With...... ultrasonography can provide information on signs of inflammation and destruction in RA finger joints that are not available with conventional radiography and clinical examination, and comparable to the information provided by magnetic resonance imaging (MRI). The second to fifth metacarpophalangeal and proximal...... interphalangeal joints of 40 RA patients and 20 control persons were assessed with ultrasonography, clinical examination, radiography and MRI. With MRI as the reference method, the sensitivity, specificity and accuracy of ultrasonography in detecting bone erosions in the finger joints were 0.59, 0.98 and 0...

  12. New radiographic bone erosions in the wrists of patients with rheumatoid arthritis are detectable with magnetic resonance imaging a median of two years earlier

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Hansen, Michael; Stoltenberg, Michael;

    2003-01-01

    progression on CR associated with the presence of MRI erosions. METHODS: In 10 patients with rheumatoid arthritis, MRI and CR of the dominant wrist were performed annually for 5 years. In each image set, each wrist bone (metacarpal bases, carpal bones, radius, and ulna) was assessed for the absence...

  13. Magnetic Resonance Facility (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2012-03-01

    This fact sheet provides information about Magnetic Resonance Facility capabilities and applications at NREL's National Bioenergy Center. Liquid and solid-state analysis capability for a variety of biomass, photovoltaic, and materials characterization applications across NREL. NREL scientists analyze solid and liquid samples on three nuclear magnetic resonance (NMR) spectrometers as well as an electron paramagnetic resonance (EPR) spectrometer.

  14. Magnetic resonance imaging, radiography, and scintigraphy of the finger joints

    DEFF Research Database (Denmark)

    Klarlund, M; Ostergaard, M; Jensen, K E;

    2000-01-01

    To evaluate synovial membrane hypertrophy, tenosynovitis, and erosion development of the 2nd to 5th metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints by magnetic resonance imaging in a group of patients with rheumatoid arthritis (RA) or suspected RA followed up for one year...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  16. Dental magnetic resonance imaging

    International Nuclear Information System (INIS)

    Growing distribution and utilization of digital volume tomography (DVT) extend the spectrum of clinical dental imaging. Additional diagnostic value, however, comes along with an increasing amount of radiation. In contrast, magnetic resonance imaging is a radiation free imaging technique. Furthermore, it offers a high soft tissue contrast. Morphological and numerical dental anomalies, differentiation of periapical lesions and exclusion of complications of dental diseases are field of applications for dental MRI. In addition, detection of caries and periodontal lesions and injury of inferior alveolar nerve are promising application areas in the future.

  17. Cranial magnetic resonance imaging

    International Nuclear Information System (INIS)

    Cranial Magnetic Resonance Imaging is comprehensive, well structured, and well written. The material is current and well referenced. The illustrations are good and complement the text well. The overall quality of publication is above average. The greatest attribute of the book is its readability. The author demonstrates ample skill in making complex subjects, such as MR physics and imaging of cerebral hemorrhage, easy to understand. The book closes with a detailed atlas on the anatomic appearance of the brain on MR images in the axial, coronal, and sagittal planes

  18. Magnetic Resonance Imaging Duodenoscope.

    Science.gov (United States)

    Syms, Richard R A; Young, Ian R; Wadsworth, Christopher A; Taylor-Robinson, Simon D; Rea, Marc

    2013-12-01

    A side-viewing duodenoscope capable of both optical and magnetic resonance imaging (MRI) is described. The instrument is constructed from MR-compatible materials and combines a coherent fiber bundle for optical imaging, an irrigation channel and a side-opening biopsy channel for the passage of catheter tools with a tip saddle coil for radio-frequency signal reception. The receiver coil is magnetically coupled to an internal pickup coil to provide intrinsic safety. Impedance matching is achieved using a mechanically variable mutual inductance, and active decoupling by PIN-diode switching. (1)H MRI of phantoms and ex vivo porcine liver specimens was carried out at 1.5 T. An MRI field-of-view appropriate for use during endoscopic retrograde cholangiopancreatography (ERCP) was obtained, with limited artefacts, and a signal-to-noise ratio advantage over a surface array coil was demonstrated. PMID:23807423

  19. Magnetic resonance imaging equipments

    International Nuclear Information System (INIS)

    Magnetic resonance imaging (MRI) is a new examination technique used in diagnostic medicine. Its use has increased notably during the last few years in Finland, too. The biological effects of electromagnetic fields used in MRI are quite different from the effects of x-rays. This report introduces the physics and the techniques of MRI; the biological effects of magnetic fields and the hazards associated with the use of MRI systems are briefly discussed. The major national and international recommendations are summarized, too. Furthermore, a description is given how safety aspects are considered in Finnish MRI units. Finally, recommendations are given to restrict the exposure caused by MRI and to ensure the safe use of MRI. Diagnostic applications and clinical or economic aspects fall outside the scope of this report. (orig.)

  20. Impact of a magnetic resonance imaging-guided treat-to-target strategy on disease activity and progression in patients with rheumatoid arthritis (the IMAGINE-RA trial)

    DEFF Research Database (Denmark)

    Møller-Bisgaard, Signe; Hørslev-Petersen, Kim; Ejbjerg, Bo Jannik;

    2015-01-01

    BACKGROUND: Rheumatoid arthritis (RA) is a chronic, progressive joint disease, which frequently leads to irreversible joint deformity and severe functional impairment. Although patients are treated according to existing guidelines and reach clinical remission, erosive progression still occurs...... for Southern Denmark, S-20110109. Dissemination will occur through presentations and publication in international peer-reviewed journals. TRIAL REGISTRATION: The study is registered in http://www.ClinicalTrials.gov identifier: NCT01656278 (5 July 2012)....

  1. Cardiovascular Magnetic Resonance Imaging

    Science.gov (United States)

    Pelc, Norbert

    2000-03-01

    Cardiovascular diseases are a major source of morbidity and mortality in the United States. Early detection of disease can often be used to improved outcomes, either through direct interventions (e.g. surgical corrections) or by causing the patient to modify his or her behavior (e.g. smoking cessation or dietary changes). Ideally, the detection process should be noninvasive (i.e. it should not be associated with significant risk). Magnetic Resonance Imaging (MRI) refers to the formation of images by localizing NMR signals, typically from protons in the body. As in other applications of NMR, a homogeneous static magnetic field ( ~0.5 to 4 T) is used to create ``longitudinal" magnetization. A magnetic field rotating at the Larmor frequency (proportional to the static field) excites spins, converting longitudinal magnetization to ``transverse" magnetization and generating a signal. Localization is performed using pulsed gradients in the static field. MRI can produce images of 2-D slices, 3-D volumes, time-resolved images of pseudo-periodic phenomena such as heart function, and even real-time imaging. It is also possible to acquire spatially localized NMR spectra. MRI has a number of advantages, but perhaps the most fundamental is the richness of the contrast mechanisms. Tissues can be differentiated by differences in proton density, NMR properties, and even flow or motion. We also have the ability to introduce substances that alter NMR signals. These contrast agents can be used to enhance vascular structures and measure perfusion. Cardiovascular MRI allows the reliable diagnosis of important conditions. It is possible to image the blood vessel tree, quantitate flow and perfusion, and image cardiac contraction. Fundamentally, the power of MRI as a diagnostic tool stems from the richness of the contrast mechanisms and the flexibility in control of imaging parameters.

  2. Advances in magnetic resonance 11

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 11, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters and begins with a discussion of the principles and applications of dynamic nuclear polarization, with emphasis on molecular motions and collisions, intermolecular couplings, and chemical interactions. Subsequent chapters focus on the assessment of a proposed broadband decoupling method and studies of time-domain (or Fourier transform) multiple-quantum nuclear magnetic resonance.

  3. Advances in magnetic resonance 6

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 6 focuses on the theoretical and practical aspects of applying magnetic resonance methods to various problems in physical chemistry, emphasizing the different aspects of the exegesis of these problems. This book discusses the gas phase magnetic resonance of electronically excited molecules; techniques for observing excited electronic states; NMR studies in liquids at high pressure; and effect of pressure on self-diffusion in liquids. The nuclear magnetic resonance investigations of organic free radicals; measurement of proton coupling constants by NMR; an

  4. Magnetic resonance in neuroborreliosis

    International Nuclear Information System (INIS)

    Magnetic resonance (MR) is commonly used in diagnosing infections of the central nervous system. The aim of the study is to evaluate central nervous system changes in neuroborreliosis patients. MR examinations were performed in 44 patients with clinical symptoms, epidemiology and laboratory tests results of neuroborreliosis. Abnormalities were detected in 22 patients. Most of them presented cortico-subcortical atrophy (86%). In 9 cases foci of increased signal in T2-weighted and FLAIR images were observed in white matter. They were single or multiple, located subcorticaly and paraventriculary. In 2 subjects areas of increased signal were found in the brain stem. Central nervous system abnormalities detected with MR are not specific for Lyme disease. They can suggest demyelinating lesions and/or gliosis observed in many nervous system disorders (SM, ADEM, lacunar infarcts). (author)

  5. Advances in magnetic resonance 12

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 12, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains six chapters and begins with a discussion of diffusion and self-diffusion measurements by nuclear magnetic resonance. This is followed by separate chapters on spin-lattice relaxation time in hydrogen isotope mixtures; the principles of optical detection of nuclear spin alignment and nuclear quadropole resonance; and the spin-1 behavior, including the relaxation of the quasi-invariants of the motion of a system of pairs of dipolar coupled spin-1/2 nu

  6. Four cases of Japanese patients with psoriatic arthritis in whom effective treatments by anti-tumor necrosis factor-α drugs were evaluated by magnetic resonance imaging together with improvement of skin lesions.

    Science.gov (United States)

    Yonenaga, Takenori; Saeki, Hidehisa; Nakagawa, Hidemi; Fukuchi, Osamu; Umezawa, Yoshinori; Hayashi, Mitsuha; Ito, Toshihiro; Yanaba, Koichi; Tojyo, Shinjiro; Fukuda, Kunihiko

    2015-01-01

    Because psoriatic skin lesions of psoriatic arthritis (PsA) usually precede the onset of joint symptom, dermatologists are in an ideal position to screen and find individuals with PsA early in the disease course. There have been no reports from the dermatology field evaluating the effect of anti-tumor necrosis factor (TNF)-α drugs on joint disorders using magnetic resonance imaging (MRI) in PsA patients. The purpose of this study was to elucidate the effectiveness of MRI in the evaluation of anti-TNF-α drugs on joint disease of Japanese PsA patients. Data were collected from four adult Japanese male PsA patients. MRI of the affected hand was performed at baseline and 1-7 months after infliximab or adalimumab treatment. T1 -weighted gadolinium-enhanced images with fat suppression were acquired in the coronal, sagittal and/or axial planes. We determined the apparent improvement of synovitis, periarticular inflammation, tenosynovitis and/or bone marrow edema by MRI after anti-TNF-α treatments in all the patients together with the improvement of skin lesions. We also determined in one patient that these symptoms detected by MRI before treatment were alleviated within 1 month and had disappeared 6 months after treatment, suggesting the potentially early detection of the effect of anti-TNF-α drugs on joint disease. We present four cases of Japanese patients with PsA in whom effective treatments by anti-TNF-α drugs were evaluated by contrast-enhanced MRI. This imaging enables dermatologists and radiologists to assess and monitor early inflammatory changes, and to grant PsA patients earlier access to modern treatment such as biologics.

  7. Advances in magnetic resonance 1

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 1, discusses developments in various areas of magnetic resonance. The subject matter ranges from original theoretical contributions through syntheses of points of view toward series of phenomena to critical and painstaking tabulations of experimental data. The book contains six chapters and begins with a discussion of the theory of relaxation processes. This is followed by separate chapters on the development of magnetic resonance techniques for studying rate processes in chemistry and the application of these techniques to various problems; the geometri

  8. Advances in magnetic resonance 9

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 9 describes the magnetic resonance in split constants and dipolar relaxation. This book discusses the temperature-dependent splitting constants in the ESR spectra of organic free radicals; temperature-dependent splittings in ion pairs; and magnetic resonance induced by electrons. The electron impact excitation of atoms and molecules; intramolecular dipolar relaxation in multi-spin systems; and dipolar cross-correlation problem are also elaborated. This text likewise covers the NMR studies of molecules oriented in thermotropic liquid crystals and diffusion

  9. Functional magnetic resonance imaging.

    Science.gov (United States)

    Buchbinder, Bradley R

    2016-01-01

    Functional magnetic resonance imaging (fMRI) maps the spatiotemporal distribution of neural activity in the brain under varying cognitive conditions. Since its inception in 1991, blood oxygen level-dependent (BOLD) fMRI has rapidly become a vital methodology in basic and applied neuroscience research. In the clinical realm, it has become an established tool for presurgical functional brain mapping. This chapter has three principal aims. First, we review key physiologic, biophysical, and methodologic principles that underlie BOLD fMRI, regardless of its particular area of application. These principles inform a nuanced interpretation of the BOLD fMRI signal, along with its neurophysiologic significance and pitfalls. Second, we illustrate the clinical application of task-based fMRI to presurgical motor, language, and memory mapping in patients with lesions near eloquent brain areas. Integration of BOLD fMRI and diffusion tensor white-matter tractography provides a road map for presurgical planning and intraoperative navigation that helps to maximize the extent of lesion resection while minimizing the risk of postoperative neurologic deficits. Finally, we highlight several basic principles of resting-state fMRI and its emerging translational clinical applications. Resting-state fMRI represents an important paradigm shift, focusing attention on functional connectivity within intrinsic cognitive networks. PMID:27432660

  10. Magnetic resonance energy and topological resonance energy.

    Science.gov (United States)

    Aihara, Jun-Ichi

    2016-04-28

    Ring-current diamagnetism of a polycyclic π-system is closely associated with thermodynamic stability due to the individual circuits. Magnetic resonance energy (MRE), derived from the ring-current diamagnetic susceptibility, was explored in conjunction with graph-theoretically defined topological resonance energy (TRE). For many aromatic molecules, MRE is highly correlative with TRE with a correlation coefficient of 0.996. For all π-systems studied, MRE has the same sign as TRE. The only trouble with MRE may be that some antiaromatic and non-alternant species exhibit unusually large MRE-to-TRE ratios. This kind of difficulty can in principle be overcome by prior geometry-optimisation or by changing spin multiplicity. Apart from the semi-empirical resonance-theory resonance energy, MRE is considered as the first aromatic stabilisation energy (ASE) defined without referring to any hypothetical polyene reference.

  11. Pre-treatment whole blood gene expression is associated with 14-week response assessed by dynamic contrast enhanced magnetic resonance imaging in infliximab-treated rheumatoid arthritis patients.

    Directory of Open Access Journals (Sweden)

    Kenzie D MacIsaac

    Full Text Available Approximately 30% of rheumatoid arthritis patients achieve inadequate response to anti-TNF biologics. Attempts to identify molecular biomarkers predicting response have met with mixed success. This may be attributable, in part, to the variable and subjective disease assessment endpoints with large placebo effects typically used to classify patient response. Sixty-one patients with active RA despite methotrexate treatment, and with MRI-documented synovitis, were randomized to receive infliximab or placebo. Blood was collected at baseline and genome-wide transcription in whole blood was measured using microarrays. The primary endpoint in this study was determined by measuring the transfer rate constant (Ktrans of a gadolinium-based contrast agent from plasma to synovium using MRI. Secondary endpoints included repeated clinical assessments with DAS28(CRP, and assessments of osteitis and synovitis by the RAMRIS method. Infliximab showed greater decrease from baseline in DCE-MRI Ktrans of wrist and MCP at all visits compared with placebo (P<0.001. Statistical analysis was performed to identify genes associated with treatment-specific 14-week change in Ktrans. The 256 genes identified were used to derive a gene signature score by averaging their log expression within each patient. The resulting score correlated with improvement of Ktrans in infliximab-treated patients and with deterioration of Ktrans in placebo-treated subjects. Poor responders showed high expression of activated B-cell genes whereas good responders exhibited a gene expression pattern consistent with mobilization of neutrophils and monocytes and high levels of reticulated platelets. This gene signature was significantly associated with clinical response in two previously published whole blood gene expression studies using anti-TNF therapies. These data provide support for the hypothesis that anti-TNF inadequate responders comprise a distinct molecular subtype of RA characterized by

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose and treat ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - ...

  14. Magnetic resonance imaging the basics

    CERN Document Server

    Constantinides, Christakis

    2014-01-01

    Magnetic resonance imaging (MRI) is a rapidly developing field in basic applied science and clinical practice. Research efforts in this area have already been recognized with five Nobel prizes awarded to seven Nobel laureates in the past 70 years. Based on courses taught at The Johns Hopkins University, Magnetic Resonance Imaging: The Basics provides a solid introduction to this powerful technology. The book begins with a general description of the phenomenon of magnetic resonance and a brief summary of Fourier transformations in two dimensions. It examines the fundamental principles of physics for nuclear magnetic resonance (NMR) signal formation and image construction and provides a detailed explanation of the mathematical formulation of MRI. Numerous image quantitative indices are discussed, including (among others) signal, noise, signal-to-noise, contrast, and resolution. The second part of the book examines the hardware and electronics of an MRI scanner and the typical measurements and simulations of m...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose and treat medical ... CD. Currently, MRI is the most sensitive imaging test of the head (particularly the brain) in routine ...

  16. Advances in magnetic resonance 2

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 2, features a mixture of experimental and theoretical contributions. The book contains four chapters and begins with an ambitious and general treatment of the problem of signal-to-noise ratio in magnetic resonance. This is followed by separate chapters on the interpretation of nuclear relaxation in fluids, with special reference to hydrogen; and various aspects of molecular theory of importance in NMR.

  17. Advances in magnetic resonance 4

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 4 deals with the relaxation, irradiation, and other dynamical effects that is specific to systems having resolved structure in their magnetic resonance spectra. This book discusses the anisotropic rotation of molecules in liquids by NMR quadrupolar relaxation; rotational diffusion constants; alternating linewidth effect; and theoretical formulations of the problem. The line shapes in high-resolution NMR; matrix representations of the equations of motion; matrix representations of the equations of motion; and intramolecular hydrogen bonds are also delibera

  18. Intraoperative magnetic resonance imaging.

    Science.gov (United States)

    Hall, Walter A; Truwit, Charles L

    2011-01-01

    Neurosurgeons have become reliant on image-guidance to perform safe and successful surgery both time-efficiently and cost-effectively. Neuronavigation typically involves either rigid (frame-based) or skull-mounted (frameless) stereotactic guidance derived from computed tomography (CT) or magnetic resonance imaging (MRI) that is obtained days or immediately before the planned surgical procedure. These systems do not accommodate for brain shift that is unavoidable once the cranium is opened and cerebrospinal fluid is lost. Intraoperative MRI (ioMRI) systems ranging in strength from 0.12 to 3 Tesla (T) have been developed in part because they afford neurosurgeons the opportunity to accommodate for brain shift during surgery. Other distinct advantages of ioMRI include the excellent soft tissue discrimination, the ability to view the surgical site in three dimensions, and the ability to "see" tumor beyond the surface visualization of the surgeon's eye, either with or without a surgical microscope. The enhanced ability to view the tumor being biopsied or resected allows the surgeon to choose a safe surgical corridor that avoids critical structures, maximizes the extent of the tumor resection, and confirms that an intraoperative hemorrhage has not resulted from surgery. Although all ioMRI systems allow for basic T1- and T2-weighted imaging, only high-field (>1.5 T) MRI systems are capable of MR spectroscopy (MRS), MR angiography (MRA), MR venography (MRV), diffusion-weighted imaging (DWI), and brain activation studies. By identifying vascular structures with MRA and MRV, it may be possible to prevent their inadvertent injury during surgery. Biopsying those areas of elevated phosphocholine on MRS may improve the diagnostic yield for brain biopsy. Mapping out eloquent brain function may influence the surgical path to a tumor being resected or biopsied. The optimal field strength for an ioMRI-guided surgical system and the best configuration for that system are as yet

  19. Magnetic Resonance Imaging of Thoracic Aortic Dissections

    OpenAIRE

    Sax, Steven L.

    1990-01-01

    Magnetic resonance imaging is an excellent noninvasive method for evaluating thoracic aortic dissections. A variety of magnetic resonance scans of aortic dissections are shown, documenting the ability of magnetic resonance to image the true lumen, the false channel, and the intimal septum. Detail is provided on magnetic resonance imaging techniques and findings. (Texas Heart Institute Journal 1990;17:262-70)

  20. Advances in magnetic resonance 5

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 5 deals with the interpretation of ESR spectra and provides descriptions of experimental apparatus. This book discusses the halogen hyperfine interactions; organic radicals in single crystals; pulsed-Fourier-transform nuclear magnetic resonance spectrometer; and inhomogenizer and decoupler. The spectrometers for multiple-pulse NMR; weak collision theory of relaxation in the rotating frame; and spin Hamiltonian for the electron spin resonance of irradiated organic single crystals are also deliberated. This text likewise covers the NMR in helium three and m

  1. Change in CD3 positive T-cell expression in psoriatic arthritis synovium correlates with change in DAS28 and magnetic resonance imaging synovitis scores following initiation of biologic therapy - a single centre, open-label study

    LENUS (Irish Health Repository)

    Pontifex, Eliza K

    2011-01-27

    Abstract Introduction With the development of increasing numbers of potential therapeutic agents in inflammatory disease comes the need for effective biomarkers to help screen for drug efficacy and optimal dosing regimens early in the clinical trial process. This need has been recognized by the Outcome Measures in Rheumatology Clinical Trials (OMERACT) group, which has established guidelines for biomarker validation. To seek a candidate synovial biomarker of treatment response in psoriatic arthritis (PsA), we determined whether changes in immunohistochemical markers of synovial inflammation correlate with changes in disease activity scores assessing 28 joints (ΔDAS28) or magnetic resonance imaging synovitis scores (ΔMRI) in patients with PsA treated with a biologic agent. Methods Twenty-five consecutive patients with PsA underwent arthroscopic synovial biopsies and MRI scans of an inflamed knee joint at baseline and 12 weeks after starting treatment with either anakinra (first 10 patients) or etanercept (subsequent 15 patients) in two sequential studies of identical design. DAS28 scores were measured at both time points. Immunohistochemical staining for CD3, CD68 and Factor VIII (FVIII) was performed on synovial samples and scored by digital image analysis (DIA). MRI scans performed at baseline and at 12 weeks were scored for synovitis semi-quantitatively. The ΔDAS28 of the European League Against Rheumatism good response definition (>1.2) was chosen to divide patients into responder and non-responder groups. Differences between groups (Mann Whitney U test) and correlations between ΔDAS28 with change in immunohistochemical and MRI synovitis scores (Spearman\\'s rho test) were calculated. Results Paired synovial samples and MRI scans were available for 21 patients (8 anakinra, 13 etanercept) and 23 patients (8 anakinra, 15 etanercept) respectively. Change in CD3 (ΔCD3) and CD68 expression in the synovial sublining layer (ΔCD68sl) was significantly greater in

  2. GHz nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Cross, T.A.; Drobny, G.; Trewhella, J.

    1994-12-01

    For the past dozen years, 500- and 600-MHz spectrometers have become available in many laboratories. The first 600-MHz NMR spectrometer (at Carnegie Mellon University) was commissioned more than 15 years ago and, until 1994, represented the highest field available for high-resolution NMR. This year, we have witnessed unprecedented progress in the development of very high field magnets for NMR spectroscopy, including the delivery of the first commercial 750-MHz NMR spectrometers. In addition, NMR signals have been obtained from 20-Tesla magnets (850 MHz for {sup 1}H`s) at both Los Alamos National Laboratory and Florida State University in the NHMFL (National High Magnetic Field Laboratory). These preliminary experiments have been performed in magnets with 100-ppm homogeneity, but a 20-Tesla magnet developed for the NHMFL will be brought to field this year with a projected homogeneity of 0.1 ppm over a 1-cm-diam spherical volume.

  3. magnetic resonance imaging,etc.

    Institute of Scientific and Technical Information of China (English)

    张福基

    1998-01-01

    magnetic resonance imaging n.[1984] a noninvasive diagnostic technique that produces computerized images of internal body tissues and is based on nuclear magnetic resonance of atoms within he body induced by the application of radio waves磁共振成像(指一种非侵害 性诊断技术,能生成内部身体组织的计算机化影像,其依据是应用无线电波 感生体内原子并使之产磁共振)

  4. Recommendations concerning magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    In medicine the technique of nuclear magnetic resonance (NMR) is applied in the form of in vivo nuclear magnetic resonance spectroscopy (MRS). In vivo MRS can be carried out non-invasively. The committee of the Dutch Health Council briefly discusses the qualities and potentialities of the nuclei that will probably be used in future clinical spectroscopy: 31P, 13C, 1H (and possibly 19F and 23Na). The committee discusses several possibilities of combining imaging and spectroscopy. The imaging of nuclei other than protons is also possible with MRS. Potential applications are considered in oncology, cardiology, neurology and hepatology. (Auth.)

  5. Advances in magnetic resonance 8

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 8 describes the magnetic resonance in spin polarization and saturation transfer. This book discusses the theory of chemically induced dynamic spin polarization; basic results for the radical-pair mechanism; and optical spin polarization in molecular crystals. The theory of optical electronic polarization (OEP); NMR in flowing systems; and applications of NMR in a flowing liquid are also elaborated. This text likewise covers the saturation transfer spectroscopy; studies of spin labels in the intermediate and fast motion regions; and spin-density matrix and

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  7. Advances in magnetic and optical resonance

    CERN Document Server

    Warren, Warren S

    1997-01-01

    Since 1965, Advances in Magnetic and Optical Resonance has provided researchers with timely expositions of fundamental new developments in the theory of, experimentation with, and application of magnetic and optical resonance.

  8. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Science.gov (United States)

    ... produced by: Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  9. Magnetometer of nuclear magnetic resonance

    International Nuclear Information System (INIS)

    We present a nuclear magnetic resonance magnetometer that measures magnetic fields, between 2,500 gauss and 5,000 gauss, with an accuracy of a few parts per million. The circuit of the magnetometer, based on a marginal oscillator, permits a continuous tunning in the frequency range comprised between 10.0 MHz, with a signal to noise ratio of about 20. The radiofrequency amplifier is of the cascode type in integrated circuit and it operates with two 9V batteries. The modulation is at 35 Hz and it is provided by an external oscillator. The instrument is compact, inexpensive and easy to operate; it can also be used for didactic purposes to show the phenomenon of magnetic nuclear resonance and its main characteristics. (author)

  10. Optically detected magnetic resonance imaging

    International Nuclear Information System (INIS)

    Optically detected magnetic resonance provides ultrasensitive means to detect and image a small number of electron and nuclear spins, down to the single spin level with nanoscale resolution. Despite the significant recent progress in this field, it has never been combined with the power of pulsed magnetic resonance imaging techniques. Here, we demonstrate how these two methodologies can be integrated using short pulsed magnetic field gradients to spatially encode the sample. This result in what we denote as an 'optically detected magnetic resonance imaging' technique. It offers the advantage that the image is acquired in parallel from all parts of the sample, with well-defined three-dimensional point-spread function, and without any loss of spectroscopic information. In addition, this approach may be used in the future for parallel but yet spatially selective efficient addressing and manipulation of the spins in the sample. Such capabilities are of fundamental importance in the field of quantum spin-based devices and sensors

  11. Pediatric Body Magnetic Resonance Imaging.

    Science.gov (United States)

    Kandasamy, Devasenathipathy; Goyal, Ankur; Sharma, Raju; Gupta, Arun Kumar

    2016-09-01

    Magnetic resonance imaging (MRI) is a radiation-free imaging modality with excellent contrast resolution and multiplanar capabilities. Since ionizing radiation is an important concern in the pediatric population, MRI serves as a useful alternative to computed tomography (CT) and also provides additional clues to diagnosis, not discernible on other investigations. Magnetic resonance cholangiopancreatography (MRCP), urography, angiography, enterography, dynamic multiphasic imaging and diffusion-weighted imaging provide wealth of information. The main limitations include, long scan time, need for sedation/anesthesia, cost and lack of widespread availability. With the emergence of newer sequences and variety of contrast agents, MRI has become a robust modality and may serve as a one-stop shop for both anatomical and functional information. PMID:26916887

  12. Evanescent Waves Nuclear Magnetic Resonance

    DEFF Research Database (Denmark)

    Halidi, El Mohamed; Nativel, Eric; Akel, Mohamad;

    2016-01-01

    Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order to char...... a new road to a better understanding of the evanescent waves component in NMR with the opportunity to perform localized spectroscopy and imaging....

  13. Ultra-high frequency magnetic resonance imaging

    OpenAIRE

    Magill, Arthur W.

    2007-01-01

    This thesis addresses the problem of radiofrequency probe design for Ultra High Frequency Magnetic Resonance Imaging (7T). The signal-to-noise ratio available in Magnetic Resonance Imaging (MRI) is determined by the static magnetic field strength, causing a continued drive toward higher fields to enable faster image acquisition at finer spatial resolution. The resonant frequency increases linearly with static field strength. At 7T the proton resonant frequency is 300MHz, with a wavelength...

  14. Magnetic Resonance Imaging in Pediatric Elbow Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Pudas, T.; Hurme, T.; Mattila, K.; Svedstroem, E. [Univ. of Turku, (Finland). Depts. of Radiology and Pediatric Surgery

    2005-10-01

    Purpose: Magnetic resonance imaging (MRI) evaluation of pediatric elbow trauma with or without a visible fracture on radiography. Material and Methods: MRI was performed in the acute phase in 25 children with an elbow injury. Nine patients with an elbow effusion only on radiographs and 16 with a fracture or luxation seen on radiographs underwent subsequent MRI. No sedation was used. Results: MRI revealed eight occult fractures (89%) in seven out of nine patients who had only an effusion on radiographs. Based on MRI findings, septic arthritis was suspected in one patient. Two patients out of five with a supracondylar fracture on the radiograph had a cartilage lesion in the humerus. MRI depicted a 3-mm gap on the articular surface in two patients with a lateral condyle fracture, a more accurate fracture location in two patients than the radiographs, and an additional occult fracture in two patients. MRI showed a fracture not seen on radiographs in two of three patients with prior luxation. Conclusion: MRI is a sensitive and accurate method in the diagnosis of pediatric elbow injuries, especially when only an effusion is present on radiographs. Occult fractures are more common in pediatric patients with elbow injury than reported earlier.

  15. Application of magnetic resonance imaging in cervical spondylotic myelopathy

    Institute of Scientific and Technical Information of China (English)

    Chuan; Zhang; Sushant; K; Das; Dong-Jun; Yang; Han-Feng; Yang

    2014-01-01

    Cervical spondylotic myelopathy(CSM) is the most common cause of spinal cord dysfunction and is caused by static or dynamic repeated compression of the spinal cord resulting from degenerative arthritis of the cervical spine and some biological injuries to the cervical spine. The T2 signal change on conventional magnetic resonance imaging(MRI) is most commonly associated with neurological deficits. Diffusion tensor imaging and MR spectroscopy show altered microstructure and biochemistry that reflect patient-specific pathogenesis and can be used to predict neurological outcome and response to intervention. Functional MRI can help to assess the neurological functional recovery after decompression surgery for CSM.

  16. Fast magnetization reversal of nanoclusters in resonator

    OpenAIRE

    Yukalov, V. I.; Yukalova, E. P.

    2012-01-01

    An effective method for ultrafast magnetization reversal of nanoclusters is suggested. The method is based on coupling a nanocluster to a resonant electric circuit. This coupling causes the appearance of a magnetic feedback field acting on the cluster, which drastically shortens the magnetization reversal time. The influence of the resonator properties, nanocluster parameters, and external fields on the magnetization dynamics and reversal time is analyzed. The magnetization reversal time can ...

  17. Wide-range nuclear magnetic resonance detector

    Science.gov (United States)

    Sturman, J. C.; Jirberg, R. J.

    1972-01-01

    Compact and easy to use solid state nuclear magnetic resonance detector is designed for measuring field strength to 20 teslas in cryogenically cooled magnets. Extremely low noise and high sensitivity make detector applicable to nearly all types of analytical nuclear magnetic resonance measurements and can be used in high temperature and radiation environments.

  18. Comparison of magnetic resonance imaging signs and clinical findings in follow-up examinations in children and juveniles with temporomandibular joint involvement in juvenile idiopathic arthritis; Vergleich magnetresonanztomografischer und klinischer Befunde von Follow-up-Untersuchungen bei Kindern und Jugendlichen mit rheumatischer Temporomandibulararthritis

    Energy Technology Data Exchange (ETDEWEB)

    Mussler, A.; Schroeder, R.J. [Charite Berlin (Germany). Radiologie; Allozy, B. [Martin-Gropius-Krankenhaus, Eberswalde (Germany). Klinik fuer Kinder- und Jugendpsychiatrie; Landau, H. [Charite Berlin (Germany). Inst. fuer Kieferorthopaedie, Orthodontie und Kinderzahnmedizin; Kallinich, T. [Charite Berlin (Germany). Centrum fuer Frauen-, Kinder- und Jugendmedizin; Trauzeddel, R. [HELIOS Klinikum Berlin-Buch (Germany). Klinik fuer Kinder- und Jugendmedizin

    2010-01-15

    The aim of this study was to analyze the extent to which pathological findings of temporomandibular joint (TMJ) in magnetic resonance imaging (MRI) follow-up examinations are correlated with clinical symptoms in patients with TMJ involvement in juvenile ideopathic arthritis (JIA) over time. Data from 34 patients with TMJ involvement in JIA was retrospectively examined. Shortly after two clinical examinations, the first MRI and the follow-up MRI were performed. The MRI examinations took place with 1.5 T MRI. In both MRI examinations alterations on the condyle (MRI1: 88 %, MRT2: 91 %) and contrast enhancement (MRT1: 76 %, MRT2 65 %) were found most frequently. TMJ pain (65 %) and lower mouth opening capacity (65 %) were the number one finding in the first clinical examination. A statistically significant correlation was found between the alterations on the condyle and TMJ pain (p = 0.025) and between the alterations on the condyle and lower mouth opening capacity (p = 0.019). By comparing the results of the first MRI with the results of the follow-up MRI, we identified a trend towards a progression of TMJ arthritis, while the clinical follow-up showed an improvement in most patients. We found a discrepancy between the progressive or stable trends of pathological findings in follow-up MRI and the decrease in clinical symptoms over time. Therefore, follow-up examination by MRI shows important information for correct evaluation about the stage of TMJ arthritis and about the need for treatment. Consequently, follow-up examination by MRI is an appropriate addition to clinical examination in the therapeutic concept. (orig.)

  19. Advances in magnetic resonance 3

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 3, describes a number of important developments which are finding increasing application by chemists. The book contains five chapters and begins with a discussion of how the properties of random molecular rotations reflect themselves in NMR and how they show up, often differently, in other kinds of experiments. This is followed by separate chapters on the Kubo method, showing its equivalence to the Redfield approach in the cases of most general interest; the current state of dynamic nuclear polarization measurements in solutions and what they tell us abou

  20. Hyperpolarized Renal Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Laustsen, Christoffer

    2016-01-01

    The introduction of dissolution dynamic nuclear polarization (d-DNP) technology has enabled a new paradigm for renal imaging investigations. It allows standard magnetic resonance imaging complementary renal metabolic and functional fingerprints within seconds without the use of ionizing radiation....... Increasing evidence supports its utility in preclinical research in which the real-time interrogation of metabolic turnover can aid the physiological and pathophysiological metabolic and functional effects in ex vivo and in vivo models. The method has already been translated to humans, although the clinical...

  1. Evanescent Waves Nuclear Magnetic Resonance.

    Science.gov (United States)

    Halidi, El Mohamed; Nativel, Eric; Akel, Mohamad; Kenouche, Samir; Coillot, Christophe; Alibert, Eric; Jabakhanji, Bilal; Schimpf, Remy; Zanca, Michel; Stein, Paul; Goze-Bac, Christophe

    2016-01-01

    Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order to characterize and model evanescent electromagnetic fields originating from NMR phenomenon. We report that in this experimental configuration the available NMR signal is one order of magnitude larger and follows an exponential decay inversely proportional to the size of the emitters. Those investigations open a new road to a better understanding of the evanescent waves component in NMR with the opportunity to perform localized spectroscopy and imaging.

  2. Introduction to Nuclear Magnetic Resonance

    Science.gov (United States)

    Manatt, Stanley L.

    1985-01-01

    The purpose of this paper is to try to give a short overview of what the status is on nuclear magnetic resonance (NMR). It's a subject where one really has to spend some time to look at the physics in detail to develop a proper working understanding. I feel it's not appropriate to present to you density matrices, Hamiltonians of all sorts, and differential equations representing the motion of spins. I'm really going to present some history and status, and show a few very simple concepts involved in NMR. It is a form of radio frequency spectroscopy and there are a great number of nuclei that can be studied very usefully with the technique. NMR requires a magnet, a r.f. transmitter/receiver system, and a data acquisition system.

  3. Diagnostic value of magnetic resonance imaging in early rheumatoid arthritis%磁共振成像在早期类风湿性关节炎诊断中的价值

    Institute of Scientific and Technical Information of China (English)

    刘悌; 陈基明

    2014-01-01

    Objective:To assess the diagnostic value of magnetic resonance imaging(MRI) for rheumatoid arthritis(RA) in its early stage.Methods:Thirty-two cases confirmed as early RA by follow-up were included.The total cases underwent conventional examination of the wrist joint by X-ray plain film and plain MRI,and 15 were given additional dynamic contrast enhanced(DCE-MRI).The results were determined concerning abnormal X-ray and MRI manifestation,time-intensity curve (TIC) and the thickness of synovial membrane measured on DCE-MRI,on which basis the bone erosion was summed up and calculated.Results:X-ray plain film only exposed respectively the bone erosion in 3 and osteoporosis in 1of 32 patients with early RA. Abnormal MRI findings for the early RA included thickened synovia and synovitis in the total 32 cases,hydrarthrosis in 18,bone marrow edema in 17,bone erosion in 15 and tenosynovitis in 21,respectively.MRI enhancement to a certain extend was observed pertaining to synovial thickening,synovitis,bone marrow edema,bone erosion and tenosynovitis.TIC in DCE-MRI for the 15 cases showed that 2 were I-type curve ( rapid increase );12 Ⅱ-type curve (platform type);and 1,Ⅲ-type curve (delayed elevation).The synovial membrane thickening was(3.5 ±0.4)mm on average,and MRI led to higher detection rate in bone destruction than conventional X-ray plain film.Conclusion:MRI examination may reveal pathologic process for early RA ,and is su-perior to conventional X-ray in diagnosis of this entity.In addition,combined use of contrast-enhanced MRI and DEC-MRI may lead to evaluation of RA ac-tivity in its early stage.%目的:探讨MRI在早期类风湿性关节炎( RA)诊断中的价值。方法:随访至明确诊断为早期RA患者32例纳入研究。所有病例均进行腕关节X线平片和MRI平扫+增强检查,其中15例行MRI动态增强扫描检查,分析X线平片异常征象及MRI异常征象、时间-信号强度曲线( TIC),测量滑膜厚度,并

  4. Tunable Magnetic Resonance in Microwave Spintronics Devices

    Science.gov (United States)

    Chen, Yunpeng; Fan, Xin; Xie, Yunsong; Zhou, Yang; Wang, Tao; Wilson, Jeffrey D.; Simons, Rainee N.; Chui, Sui-Tat; Xiao, John Q.

    2015-01-01

    Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe based tunable microwave spintronics devices, which is 10X higher than conventional methods.

  5. Magnetic resonance imaging of hemochromatosis arthropathy

    International Nuclear Information System (INIS)

    This study was undertaken to compare plain film radiography and magnetic resonance imaging in the assessment of hemochromatosis arthropathy of the knees of ten patients with a biopsy-proven diagnosis. Both modalities enabled visualisation of bony degenerative changes; magnetic resonance imaging enabled additional visualization of deformity of both cartilage and menisci. Magnetic resonance imaging failed reliably to confirm the presence of intra-articular iron in the patients studied. No correlation was observed between synovial fluid magnetic resonance signal values, corresponding serum ferritin levels, or the severity of the observed degenerative changes. (orig.)

  6. Magnetic resonance imaging of hemochromatosis arthropathy

    Energy Technology Data Exchange (ETDEWEB)

    Eustace, S. [Dept. of Radiology, Deaconess Hospital and Harvard Medical School, Boston, MA (United States); Buff, B. [Dept. of Radiology, Deaconess Hospital and Harvard Medical School, Boston, MA (United States); McCarthy, C. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland); MacMathuana, P. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland); Gilligan, P. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland); Ennis, J.T. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland)

    1994-10-01

    This study was undertaken to compare plain film radiography and magnetic resonance imaging in the assessment of hemochromatosis arthropathy of the knees of ten patients with a biopsy-proven diagnosis. Both modalities enabled visualisation of bony degenerative changes; magnetic resonance imaging enabled additional visualization of deformity of both cartilage and menisci. Magnetic resonance imaging failed reliably to confirm the presence of intra-articular iron in the patients studied. No correlation was observed between synovial fluid magnetic resonance signal values, corresponding serum ferritin levels, or the severity of the observed degenerative changes. (orig.)

  7. Society for Cardiovascular Magnetic Resonance guidelines for reporting cardiovascular magnetic resonance examinations

    OpenAIRE

    van Rossum Albert C; Raman Subha V; McConnell Michael V; Lawson Mark A; Higgins Charles B; Friedrich Matthias G; Bogaert Jan G; Bluemke David; Hundley W Gregory; Flamm Scott; Kramer Christopher M; Nagel Eike; Neubauer Stefan

    2009-01-01

    Abstract These reporting guidelines are recommended by the Society for Cardiovascular Magnetic Resonance (SCMR) to provide a framework for healthcare delivery systems to disseminate cardiac and vascular imaging findings related to the performance of cardiovascular magnetic resonance (CMR) examinations.

  8. Validity of Ultrasonography and Measures of Adult Shoulder Function and Reliability of Ultrasonography in Detecting Shoulder Synovitis in Patients With Rheumatoid Arthritis Using Magnetic Resonance Imaging as a Gold Standard

    NARCIS (Netherlands)

    Bruyn, G. A. W.; Pineda, C.; Hernandez-Diaz, C.; Ventura-Rios, L.; Moya, C.; Garrido, J.; Groen, H.; Pena, A.; Espinosa, R.; Moeller, I.; Filippucci, E.; Iagnocco, A.; Balint, P. V.; Kane, D.; D'Agostino, M-A; Angulo, M.; Ponte, R.; Fernandez-Gallardo, J. M.; Naredo, E.; Moller, I.

    2010-01-01

    Objective. To assess the intra- and interobserver reproducibility of musculoskeletal ultrasonography (US) in detecting inflammatory shoulder changes in patients with rheumatoid arthritis, and to determine the agreement between US and the Shoulder Pain and Disability Index (SPADI) and the Disabilitie

  9. Fetal abdominal magnetic resonance imaging

    International Nuclear Information System (INIS)

    This review deals with the in vivo magnetic resonance imaging (MRI) appearance of the human fetal abdomen. Imaging findings are correlated with current knowledge of human fetal anatomy and physiology, which are crucial to understand and interpret fetal abdominal MRI scans. As fetal MRI covers a period of more than 20 weeks, which is characterized not only by organ growth, but also by changes and maturation of organ function, a different MR appearance of the fetal abdomen results. This not only applies to the fetal intestines, but also to the fetal liver, spleen, and adrenal glands. Choosing the appropriate sequences, various aspects of age-related and organ-specific function can be visualized with fetal MRI, as these are mirrored by changes in signal intensities. Knowledge of normal development is essential to delineate normal from pathological findings in the respective developmental stages

  10. Magnetic Resonance Imaging of Neurosarcoidosis

    Directory of Open Access Journals (Sweden)

    Daniel T Ginat

    2011-01-01

    Full Text Available Neurosarcoidosis is an uncommon condition with protean manifestations. Magnetic resonance imaging (MRI is often used in the diagnostic evaluation and follow-up of patients with neurosarcoidosis. Therefore, familiarity with the variety of MRI appearances is important. In this pictorial essay, the range of possible patterns of involvement in neurosarcoidosis are depicted and discussed. These include intracranial and spine leptomeningeal involvement, cortical and cerebral white matter lesions, corpus callosum involvement, sellar and suprasellar involvement, periventricular involvement, cranial nerve involvement, cavernous sinus involvement, hydrocephalus, dural involvement, ischemic lesions, perivascular involvement, orbit lesions, osseous involvement, nerve root involvement, and spinal cord intramedullary involvement. Differential diagnoses for each pattern of involvement of neurosarcoidosis are also provided.

  11. Chemical Principles Revisited. Proton Magnetic Resonance Spectroscopy.

    Science.gov (United States)

    McQuarrie, Donald A.

    1988-01-01

    Discusses how to interpret nuclear magnetic resonance (NMR) spectra and how to use them to determine molecular structures. This discussion is limited to spectra that are a result of observation of only the protons in a molecule. This type is called proton magnetic resonance (PMR) spectra. (CW)

  12. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C;

    1987-01-01

    Magnetic resonance imaging offers new possibilities in the investigation of the prostate. The current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be of value in the staging of carcinoma of the prostate....

  13. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C;

    1988-01-01

    Magnetic resonance imaging offers new possibilities in investigation of the prostate gland. Current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be useful in the staging of carcinoma of the prostate....

  14. Functional Magnetic Resonance Imaging and Pediatric Anxiety

    Science.gov (United States)

    Pine, Daniel S.; Guyer, Amanda E.; Leibenluft, Ellen; Peterson, Bradley S.; Gerber, Andrew

    2008-01-01

    The use of functional magnetic resonance imaging in investigating pediatric anxiety disorders is studied. Functional magnetic resonance imaging can be utilized in demonstrating parallels between the neural architecture of difference in anxiety of humans and the neural architecture of attention-orienting behavior in nonhuman primates or rodents.…

  15. Contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    The origine of nuclear magnetic resonance signal is reminded and different ways for contrast enhancement in magnetic resonance imaging are presented, especially, modifications of tissus relaxation times. Investigations have focused on development of agents incorporating either paramagnetic ions or stable free radicals. Pharmacological and toxicological aspects are developed. The diagnostic potential of these substances is illustrated by the example of gadolinium complexes

  16. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... produced by: Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  17. Nuclear magnetic resonance studies of erythrocyte membranes

    NARCIS (Netherlands)

    Chapman, D.; Kamat, V.B.; Gier, J. de; Penkett, S.A.

    1968-01-01

    The use of nuclear magnetic resonance spectroscopy for studying molecular interactions in biological membranes has been investigated using erythrocyte membrane fragments. Sonic dispersion of these fragments produces a sharp and well-defined high-resolution nuclear magnetic resonance spectrum. The sp

  18. Magnetic non-collinear neutron wave resonator

    CERN Document Server

    Khaidukov, Yu N

    2009-01-01

    The expression are received for amplitude of neutron reflection from layered magnetic non-collinear structure (neutron wave resonator (NWR)). It is showed the magnetic non-collinear NWR is characterized by the system of pairs of resonances for the spin flipped neutrons. The conditions are defined at which amplifying of spin-flipped neutron flux in wave resonator is multiple increased in comparison with amplifying of neutron absorption.

  19. Early rheumatoid arthritis and its differentiation from other joint abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Boutry, Nathalie [Department of Musculoskeletal Radiology (France)], E-mail: nboutry@chru-lille.fr; Carmo, Clarissa Canella Moraes do [Department of Musculoskeletal Radiology (France); Flipo, Rene-Marc [Department of Rheumatology (France); Cotten, Anne [Department of Musculoskeletal Radiology (France)

    2009-08-15

    The introduction of disease-modifying antirheumatic drugs has created new demands on imaging to early identify patients with rheumatoid arthritis and opened new prospects in therapeutic management of patients with aggressive disease. Therefore, new imaging modalities such as magnetic resonance imaging and ultrasound have developed during the past few years in this field. In some cases, both magnetic resonance imaging and ultrasound may be also useful in making the distinction between early rheumatoid arthritis and other joints abnormalities, including early psoriatic arthritis. This article will review key aspects of important advances in imaging in rheumatoid arthritis, particularly focusing on magnetic resonance imaging and ultrasound.

  20. Stepped Impedance Resonators for High Field Magnetic Resonance Imaging

    OpenAIRE

    Akgun, Can E.; DelaBarre, Lance; Yoo, Hyoungsuk; Sohn, Sung-Min; Snyder, Carl J.; Adriany, Gregor; Ugurbil, Kamil; Gopinath, Anand; Vaughan, J. Thomas

    2014-01-01

    Multi-element volume radio-frequency (RF) coils are an integral aspect of the growing field of high field magnetic resonance imaging (MRI). In these systems, a popular volume coil of choice has become the transverse electromagnetic (TEM) multi-element transceiver coil consisting of microstrip resonators. In this paper, to further advance this design approach, a new microstrip resonator strategy in which the transmission line is segmented into alternating impedance sections referred to as step...

  1. Interaction of magnetic resonators studied by the magnetic field enhancement

    OpenAIRE

    Yumin Hou

    2013-01-01

    It is the first time that the magnetic field enhancement (MFE) is used to study the interaction of magnetic resonators (MRs), which is more sensitive than previous parameters–shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE osci...

  2. Arthritis

    Science.gov (United States)

    ... training for muscle tone. Your provider may suggest physical therapy. This might include: Heat or ice Splints or ... American College of Rheumatology guidelines for management of gout. Part 2: therapy and anti-inflammatory prophylaxis of acute gouty arthritis. ...

  3. Magnetic resonance imaging in mucopolysaccharidosis

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Seijun; Tanaka, Akemi; Kawawaki, Hisashi; Hattori, Hideji; Matsuoka, Osamu; Murata, Ryosuke; Isshiki, Gen; Inoue, Yuichi

    1988-11-01

    Magnetic resonance (MR) images in six patients with mucopolysaccharidosis (MPS), two with type I S, one with type II A, two with type III B, and one with type VI MPS, were reviewed and compared with reported pathological findings and with CT scans. We used a Picker International MR imager with a 0.5-tesla superconducting magnet. The pulse sequences involved the inversion recovery technique (TR, 2,100 msec ; TI, 600 msec ; TE, 40 msec) for the T/sub 1/-weighted images and spin echo technique (TR, 1,800 msec ; TE, 120 msec) for the T/sub 2/-weighted images. The TC scanner was a Somatom 2 or DR3. In the patients with type II A and type VI MPS, there were multi-focal lesions of various sizes that showed prolonged T/sub 1/ and T/sub 2/ in the white matter. These lesions, which were not detected by CT, seemed to be correlated with the pathological findings of cavitation and dilated periadventitial space with viscous fluid. In the patients with type II A and type III B MPS, the T/sub 2/-weighted images showed a reduced contrast between gray and white matters, which may be related to the deposition of glycolipids and mucopolysaccharides in the lysosomes of the neurons and astrocytes of the gray and white matters. These findings seemed to be correlated with the clinical finding of mental retardation. In the patient of type II A MPS, there were lesions that showed prolonged T/sub 2/ of the periventricular white matter, suggesting periventricular edema. But CT hardly detected these lesions. In the patients with type I S MPS, no abnormal findings were found in MR imaging. It was concluded that MR imaging was far more sensitive for the detection of MPS lesions than CT, and was a useful method for differential diagnosis in MPS.

  4. Magnetic resonance imaging in mucopolysaccharidosis

    International Nuclear Information System (INIS)

    Magnetic resonance (MR) images in six patients with mucopolysaccharidosis (MPS), two with type I S, one with type II A, two with type III B, and one with type VI MPS, were reviewed and compared with reported pathological findings and with CT scans. We used a Picker International MR imager with a 0.5-tesla superconducting magnet. The pulse sequences involved the inversion recovery technique (TR, 2,100 msec ; TI, 600 msec ; TE, 40 msec) for the T1-weighted images and spin echo technique (TR, 1,800 msec ; TE, 120 msec) for the T2-weighted images. The TC scanner was a Somatom 2 or DR3. In the patients with type II A and type VI MPS, there were multi-focal lesions of various sizes that showed prolonged T1 and T2 in the white matter. These lesions, which were not detected by CT, seemed to be correlated with the pathological findings of cavitation and dilated periadventitial space with viscous fluid. In the patients with type II A and type III B MPS, the T2-weighted images showed a reduced contrast between gray and white matters, which may be related to the deposition of glycolipids and mucopolysaccharides in the lysosomes of the neurons and astrocytes of the gray and white matters. These findings seemed to be correlated with the clinical finding of mental retardation. In the patient of type II A MPS, there were lesions that showed prolonged T2 of the periventricular white matter, suggesting periventricular edema. But CT hardly detected these lesions. In the patients with type I S MPS, no abnormal findings were found in MR imaging. It was concluded that MR imaging was far more sensitive for the detection of MPS lesions than CT, and was a useful method for differential diagnosis in MPS. (author)

  5. Functional magnetic resonance imaging by visual stimulation

    International Nuclear Information System (INIS)

    We evaluated functional magnetic resonance images obtained in 8 healthy subjects in response to visual stimulation using a conventional clinical magnetic resonance imaging system with multi-slice spin-echo echo planar imaging. Activation in the visual cortex was clearly demonstrated by the multi-slice experiment with a task-related change in signal intensity. In addition to the primary visual cortex, other areas were also activated by a complicated visual task. Multi-slice spin-echo echo planar imaging offers high temporal resolution and allows the three-dimensional analysis of brain function. Functional magnetic resonance imaging provides a useful noninvasive method of mapping brain function. (author)

  6. Magnetic resonance in multiple sclerosis

    International Nuclear Information System (INIS)

    Magnetic Resonance Imaging was performed in more than 200 patients with clinical suspicion or knowledge of Multiple Sclerosis. One hundred and forty-seven (60 males and 87 females) had MR evidence of multiple sclerosis lesions. The MR signal of demyelinating plaques characteristically has prolonged T1 and T2 relaxation times and the T2-weighted spin-echo sequences are generally superior to the T1-weighted images because the lesions are better visualized as areas of increased signal intensity. MR is also able to detect plaques in the brainstem, cerebellum and within the cervical spinal cord. MR appears to be an important, non-invasive method for the diagnosis of Multiple Sclerosis and has proven to be diagnostically superior to CT, evoked potentials (EP) and CSF examination. In a selected group of 30 patients, with the whole battery of the relevant MS studies, MR was positive in 100%, CT in 33,3%, EP in 56% and CSF examination in 60%. In patients clinically presenting only with signs of spinal cord involvement or optic neuritis or when the clinical presentation is uncertain MR has proven to be a very useful diagnostic tool for diagnosis of MS by demonstrating unsuspected lesions in the cerebral hemispheres. (orig.)

  7. A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph

    Directory of Open Access Journals (Sweden)

    K. Bartušek

    2003-01-01

    Full Text Available This paper describes a method for measuring of the gradient magnetic field in Nuclear Magnetic Resonance (NMR tomography, which is one of the modern medical diagnostic methods. A very important prerequisite for high quality imaging is a gradient magnetic field in the instrument with exactly defined properties. Nuclear magnetic resonance enables us to measure the pulse gradient magnetic field characteristics with high accuracy. These interesting precise methods were designed, realised, and tested at the Institute of Scientific Instruments (ISI of the Academy of Sciences of the Czech Republic. The first of them was the Instantaneous Frequency (IF method, which was developed into the Instantaneous Frequency of Spin Echo (IFSE and the Instantaneous Frequency of Spin Echo Series (IFSES methods. The above named methods are described in this paper and their a comparison is also presented.

  8. Enhancement of artificial magnetism via resonant bianisotropy

    Science.gov (United States)

    Markovich, Dmitry; Baryshnikova, Kseniia; Shalin, Alexander; Samusev, Anton; Krasnok, Alexander; Belov, Pavel; Ginzburg, Pavel

    2016-03-01

    All-dielectric “magnetic light” nanophotonics based on high refractive index nanoparticles allows controlling magnetic component of light at nanoscale without having high dissipative losses. The artificial magnetic optical response of such nanoparticles originates from circular displacement currents excited inside those structures and strongly depends on geometry and dispersion of optical materials. Here an approach for enhancing of magnetic response via resonant bianisotropy effect is proposed and analyzed. The key mechanism of enhancement is based on electric-magnetic interaction between two electrically and magnetically resonant nanoparticles of all-dielectric dimer. It was shown that proper geometrical arrangement of the dimer in respect to the incident illumination direction allows flexible control over all vectorial components of the magnetic moment, tailoring the latter in the dynamical range of 100% and delivering enhancement up to 36% relative to performances of standalone spherical particles. The proposed approach provides pathways for designs of all-dielectric metamaterials and metasurfaces with strong magnetic responses.

  9. Reducing Field Distortion in Magnetic Resonance Imaging

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  10. Contribution to nuclear magnetic resonance imager using permanent magnets

    International Nuclear Information System (INIS)

    After some recalls of nuclear magnetic resonance, ways to get a stable and homogeneous magnetic field are studied with permanent magnets. Development of correction coils on integrated circuits has been particularly stressed. Gradient coil specific systems have been studied taking in account ferromagnetic material presence. Antenna system has been improved and possibility of image obtention with the prototype realized has been shown

  11. International Society for Magnetic Resonance in Medicine

    Science.gov (United States)

    ... Join the ISMRM Journals History & Mission Central Office Society Award Winners Strategic Plan Policies Corporate Members Contact ... E-Library Virtual Meetings Connect With Us International Society for Magnetic Resonance in Medicine 2300 Clayton Road, ...

  12. Magnetic moment of the Roper resonance

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, T. [Institut fuer Kernphysik, Johannes Gutenberg-Universitaet, D-55099 Mainz (Germany); Gegelia, J., E-mail: gegelia@kph.uni-mainz.de [Institut fuer Kernphysik, Johannes Gutenberg-Universitaet, D-55099 Mainz (Germany); Institut fuer Theoretische Physik II, Ruhr-Universitaet Bochum, 44780 Bochum (Germany); High Energy Physics Institute of TSU, 0186 Tbilisi, Georgia (United States); Scherer, S. [Institut fuer Kernphysik, Johannes Gutenberg-Universitaet, D-55099 Mainz (Germany)

    2012-08-29

    The magnetic moment of the Roper resonance is calculated in the framework of a low-energy effective field theory of the strong interactions. A systematic power-counting procedure is implemented by applying the complex-mass scheme.

  13. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Pediatric Ultrasound Video: Angioplasty & vascular stenting Video: Arthrography Radiology and You About this Site RadiologyInfo.org is ... Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot ...

  14. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... this Site RadiologyInfo.org is produced by: Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) ... Recently posted: Focused Ultrasound for Uterine Fibroids Dementia Video: General Ultrasound Video: Pediatric Nuclear Medicine Radiology and ...

  15. Magnetic moment of the Roper resonance

    OpenAIRE

    Bauer, T.; Gegelia, J.; Scherer, S.

    2012-01-01

    The magnetic moment of the Roper resonance is calculated in the framework of a low-energy effective field theory of the strong interactions. A systematic power-counting procedure is implemented by applying the complex-mass scheme.

  16. Advanced magnetic resonance spectroscopy techniques and applications

    OpenAIRE

    Cao, Peng; 曹鹏

    2013-01-01

    Magnetic resonance (MR) is a well-known non-invasive technique that provides spectra (by MR spectroscopy, MRS) and images (by magnetic resonance imaging, MRI) of the examined tissue with detailed metabolic, structural, and functional information. This doctoral work is focused on advanced methodologies and applications of MRS for probing cellular and molecular changes in vivo. A single-voxel diffusion-weighted (DW) MRS method was first developed for monitoring the size changes of intramyocellu...

  17. Nuclear Magnetic Resonance Imaging: Current Capabilities

    OpenAIRE

    Davis, Peter L.; Crooks, Lawrence E.; Margulis, Alexander R.; Kaufman, Leon

    1982-01-01

    Nuclear magnetic resonance imaging can produce tomographic images of the body without ionizing radiation. Images of the head, chest, abdomen, pelvis and extremities have been obtained and normal structures and pathology have been identified. Soft tissue contrast with this method is superior to that with x-ray computerized tomography and its spatial resolution is approaching that of x-ray computerized tomography. In addition, nuclear magnetic resonance imaging enables us to image along the sag...

  18. Magnetic Resonance Imaging with a Dielectric Lens

    OpenAIRE

    Vazquez, F.; Marrufo, O.; MARTIN,R; Rodriguez, A. O.

    2009-01-01

    Recently, metamaterials have been introduced to improve the signal-to-noise ratio (SNR) of magnetic resonance images with very promising results. However, the use polymers in the generation of high quality images in magnetic resonance imaging has not been fully been investigated. These investigations explored the use of a dielectric periodical array as a lens to improve the image SNR generated with single surface coils. Commercial polycarbonate glazing sheets were used together with a circula...

  19. Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

    Science.gov (United States)

    Lang, P.; Genant, H. K.; Jergesen, H. E.; Murray, W. R.

    1992-01-01

    The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

  20. Enhancement of artificial magnetism via resonant bianisotropy

    CERN Document Server

    Markovich, Dmitry; Shalin, Alexander; Samusev, Anton; Krasnok, Alexander; Belov, Pavel; Ginzburg, Pavel

    2015-01-01

    All-dielectric "magnetic light" nanophotonics based on high refractive index nanoparticles allows controlling magnetic component of light at nanoscale without having high dissipative losses. The artificial magnetic optical response of such nanoparticles originates from circular displacement currents excited inside those structures and strongly depends on geometry and dispersion of optical materials. Here a new approach for increasing magnetic response via resonant bianisotropy effect is proposed and analyzed. The key mechanism of enhancement is based on electric-magnetic interaction between two electrically and magnetically resonant nanoparticles of all-dielectric dimer nanoantenna. It was shown that proper geometrical arrangement of the dimer in respect to the incident illumination direction allows flexible control over all vectorial components of magnetic polarizability, tailoring the later in the dynamical range of 100 % and enhancement up to 36 % relative to performances of standalone spherical particles....

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  2. Magnetic resonance imaging in children with acute hip pain

    Energy Technology Data Exchange (ETDEWEB)

    Ranner, G.; Ebner, F.; Fotter, R.; Justich, E. (Graz Univ. (Austria). Radiologische Klinik); Linhart, W. (Graz Univ. (Austria). Kinderklinik)

    1989-11-01

    45 children presenting with acute hip pain were prospectively evaluated with conventional radiography, radioisotope bone scan, and magnetic resonance imaging (MRI). The final diagnoses were transient synovitis (n=17), septic arthritis (n=2), Legg-Calve-Perthes disease (LCPD, n=13), epiphyseal dysplasia (n=2), other conditions (n=4), and normal findings (n=7). In the work-up MRI provided more morphologic information than other techniques and enlarged the diagnostic possibilities. It was the only imaging technique able to give an early indication of bone marrow involvement in systemic diseases. For the early diagnosis of LCPD, MRI was as sensitive as isotope bone scan and more precise than conventional radiography. In the follow-up of LCPD patients MRI was not able to indicate the start of revascularisation of the necrotic area, which bone scans showed reliably in six patients: But MRI provided excellent evaluation of the position, form and size of the femoral head and the surrounding soft tissues. (orig.).

  3. Magnetic resonance imaging in spondyloarthritis--how to quantify findings and measure response

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Poggenborg, René Panduro; Axelsen, Mette Bjørndal;

    2010-01-01

    Sensitive and reliable tools for monitoring disease activity and damage, and for prognostication, are essential in the management of patients with spondyloarthritis, including ankylosing spondylitis and psoriatic arthritis. Magnetic resonance imaging (MRI) allows direct visualisation...... and clinical practice. The present article reviews key aspects of the status and recent important advances in MRI in spondyloarthritis, focussing on available MRI tools for assessing activity and damage in peripheral and, particularly, axial joints....

  4. Coherence of magnetic resonators in a metamaterial

    Directory of Open Access Journals (Sweden)

    Yumin Hou

    2013-12-01

    Full Text Available The coherence of periodic magnetic resonators (MRs under oblique incidence is studied using simulations. The correlated phase of interaction including both the retardation effect and relative phase difference between two MRs is defined, and it plays a key role in the MR interaction. The correlated phase is anisotropic, as is the coherence condition. The coherence condition is the same as the Wood's anomaly and verified by the Fano resonance. This study shows that the applications of the Fano resonance of periodic MRs will become widespread owing to achieving the Fano resonance simply by tuning the incident angle.

  5. Society for Cardiovascular Magnetic Resonance guidelines for reporting cardiovascular magnetic resonance examinations

    Directory of Open Access Journals (Sweden)

    van Rossum Albert C

    2009-03-01

    Full Text Available Abstract These reporting guidelines are recommended by the Society for Cardiovascular Magnetic Resonance (SCMR to provide a framework for healthcare delivery systems to disseminate cardiac and vascular imaging findings related to the performance of cardiovascular magnetic resonance (CMR examinations.

  6. 170 Nanometer Nuclear Magnetic Resonance Imaging using Magnetic Resonance Force Microscopy

    CERN Document Server

    Thurber, K R; Smith, D D; Thurber, Kent R.; Harrell, Lee E.; Smith, Doran D.

    2003-01-01

    We demonstrate one-dimensional nuclear magnetic resonance imaging of the semiconductor GaAs with 170 nanometer slice separation and resolve two regions of reduced nuclear spin polarization density separated by only 500 nanometers. This is achieved by force detection of the magnetic resonance, Magnetic Resonance Force Microscopy (MRFM), in combination with optical pumping to increase the nuclear spin polarization. Optical pumping of the GaAs creates spin polarization up to 12 times larger than the thermal nuclear spin polarization at 5 K and 4 T. The experiment is sensitive to sample volumes containing $\\sim 4 \\times 10^{11}$ $^{71}$Ga$/\\sqrt{Hz}$. These results demonstrate the ability of force-detected magnetic resonance to apply magnetic resonance imaging to semiconductor devices and other nanostructures.

  7. Magnetic resonance imaging of iliotibial band syndrome.

    Science.gov (United States)

    Ekman, E F; Pope, T; Martin, D F; Curl, W W

    1994-01-01

    Seven cases of iliotibial band syndrome and the pathoanatomic findings of each, as demonstrated by magnetic resonance imaging, are presented. These findings were compared with magnetic resonance imaging scans of 10 age- and sex-matched control knees without evidence of lateral knee pain. Magnetic resonance imaging signal consistent with fluid was seen deep to the iliotibial band in the region of the lateral femoral epicondyle in five of the seven cases. Additionally, when compared with the control group, patients with iliotibial band syndrome demonstrated a significantly thicker iliotibial band over the lateral femoral epicondyle (P iliotibial band in the disease group was 5.49 +/- 2.12 mm, as opposed to 2.52 +/- 1.56 mm in the control group. Cadaveric dissections were performed on 10 normal knees to further elucidate the exact nature of the area under the iliotibial band. A potential space, i.e., a bursa, was found between the iliotibial band and the knee capsule. This series suggests that magnetic resonance imaging demonstrates objective evidence of iliotibial band syndrome and can be helpful when a definitive diagnosis is essential. Furthermore, correlated with anatomic dissection, magnetic resonance imaging identifies this as a problem within a bursa beneath the iliotibial band and not a problem within the knee joint.

  8. Generation of nuclear magnetic resonance images

    International Nuclear Information System (INIS)

    Two generation techniques of nuclear magnetic resonance images, the retro-projection and the direct transformation method are studied these techniques are based on the acquisition of NMR signals which phases and frequency components are codified in space by application of magnetic field gradients. The construction of magnet coils is discussed, in particular a suitable magnet geometry with polar pieces and air gap. The obtention of image contrast by T1 and T2 relaxation times reconstructed from generated signals using sequences such as spin-echo, inversion-recovery and stimulated echo, is discussed. The mathematical formalism of matrix solution for Bloch equations is also presented. (M.C.K.)

  9. Magnetic resonance of magnetic fluid and magnetoliposome preparations

    Energy Technology Data Exchange (ETDEWEB)

    Morais, Paulo C. [Universidade de Brasilia, Instituto de Fisica, Nucleo de Fisica Aplicada, 70919-970 Brasilia-DF (Brazil)]. E-mail: pcmor@unb.br; Santos, Judes G. [Universidade de Brasilia, Instituto de Fisica, Nucleo de Fisica Aplicada, 70919-970 Brasilia-DF (Brazil); Skeff Neto, K. [Universidade de Brasilia, Instituto de Fisica, Nucleo de Fisica Aplicada, 70919-970 Brasilia-DF (Brazil); Pelegrini, Fernando [Universidade Federal de Goias, Instituto de Fisica, 74001-970 Goiania-GO (Brazil); Cuyper, Marcel de [Katholieke Universiteit Leuven, Campus Kortrijk, Interdisciplinary Research Centre, B-8500 Kortrijk (Belgium)

    2005-05-15

    In this study, magnetic resonance was used to investigate lauric acid-coated magnetite-based magnetic fluid particles and particles which are surrounded by a double layer of phospholipid molecules (magnetoliposomes). The data reveal the presence of monomers and dimers in both samples. Whereas evidence for a thermally induced disruption of dimers is found in the magnetic fluid, apparently, the bilayer phospholipid envelop prevents the dissociation in the magnetoliposome samples.

  10. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  11. Magnetic resonance imaging of the body

    Energy Technology Data Exchange (ETDEWEB)

    Higgins, C.B.; Hricak, H.

    1987-01-01

    This text provides reference to magnetic resonance imaging (MRI) of the body. Beginning with explanatory chapters on the physics, instrumentation, and interpretation of MRI, it proceeds to the normal anatomy of the neck, thorax, abdomen, and pelvis. Other chapters cover magnetic resonance imaging of blood flow, the larynx, the lymph nodes, and the spine, as well as MRI in obstetrics. The text features detailed coverage of magnetic resonance imaging of numerous disorders and disease states, including neck disease, thoracic disease; breast disease; congenital and acquired heart disease; vascular disease; diseases of the liver, pancreas, and spleen; diseases of the kidney, adrenals, and retroperitoneum; diseases of the male and female pelvis; and musculoskeletal diseases. Chapters on the biological and environmental hazards of MRI, the current clinical status of MRI in comparison to other imaging modalities, and economic considerations are also included.

  12. Tutte polynomial in functional magnetic resonance imaging

    Science.gov (United States)

    García-Castillón, Marlly V.

    2015-09-01

    Methods of graph theory are applied to the processing of functional magnetic resonance images. Specifically the Tutte polynomial is used to analyze such kind of images. Functional Magnetic Resonance Imaging provide us connectivity networks in the brain which are represented by graphs and the Tutte polynomial will be applied. The problem of computing the Tutte polynomial for a given graph is #P-hard even for planar graphs. For a practical application the maple packages "GraphTheory" and "SpecialGraphs" will be used. We will consider certain diagram which is depicting functional connectivity, specifically between frontal and posterior areas, in autism during an inferential text comprehension task. The Tutte polynomial for the resulting neural networks will be computed and some numerical invariants for such network will be obtained. Our results show that the Tutte polynomial is a powerful tool to analyze and characterize the networks obtained from functional magnetic resonance imaging.

  13. MAGNETIC RESONANCE SEMIOTICS OF BREAST CANCER

    Directory of Open Access Journals (Sweden)

    S. V. Serebryakova

    2009-01-01

    Full Text Available Breast cancer (BC that is the most common malignancy in women presents an indubitable threat to their life and health. The basis for this investigation was magnetic resonance imaging (MRI data of 203 women with histologically verified malignan- cies. The patients' mean age was 53±10.2 years. The paper describes the magnetic resonance semiotics of BC; the authors have developed criteria for dynamic contrast-enhanced magnetic resonance mammography used in the differential diagnosis of nodules.Due to high soft-tissue contrast, the use of thin sections, and the possibility of examining in any projection, MRI allows one not only to accurately visualize a pathological mass as compared with X-ray mammography or ultrasound study, but also to characterize its vascularization, which is a major criteria for the differential diagnosis of benign and malignant breast nodules.

  14. Magnetic resonance signal moment determination using the Earth's magnetic field

    KAUST Repository

    Fridjonsson, Einar Orn

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth\\'s magnetic field system.

  15. Magnetic resonance signal moment determination using the Earth's magnetic field

    Science.gov (United States)

    Fridjonsson, E. O.; Creber, S. A.; Vrouwenvelder, J. S.; Johns, M. L.

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth's magnetic field system.

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no risk, ... magnetic field is not harmful in itself, implanted medical devices that contain metal may malfunction or cause problems ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if you have asthma. The contrast material ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by a circular magnet. ... still during imaging. A person who is very large may not fit into the opening of certain ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI centers allow a friend or parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... allergies and whether there’s a possibility you are pregnant. The magnetic field is not harmful, but it ... if there is any possibility that they are pregnant. MRI has been used for scanning patients since ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... pregnant. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... number of abrupt onset or long-standing symptoms. It can help diagnose conditions such as: brain tumors ...

  4. Magnetic force microscopy using tip magnetization modulated by ferromagnetic resonance

    International Nuclear Information System (INIS)

    In magnetic force microscopy (MFM), the tip–sample distance should be reduced to analyze the microscopic magnetic domain structure with high spatial resolution. However, achieving a small tip–sample distance has been difficult because of superimposition of interaction forces such as van der Waals and electrostatic forces induced by the sample surface. In this study, we propose a new method of MFM using ferromagnetic resonance (FMR) to extract only the magnetic field near the sample surface. In this method, the magnetization of a magnetic cantilever is modulated by FMR to separate the magnetic field and topographic structure. We demonstrate the modulation of the magnetization of the cantilever and the identification of the polarities of a perpendicular magnetic medium. (paper)

  5. Progress in nuclear magnetic resonance spectroscopy

    CERN Document Server

    Emsley, J W; Sutcliffe, L H

    2013-01-01

    Progress in Nuclear Magnetic Resonance Spectroscopy, Part 1 is a two-chapter text that reviews significant developments in nuclear magnetic resonance (NMR) applications.The first chapter discusses NMR studies of molecules physisorbed on homogeneous surfaces. This chapter also describes the phase changes in the adsorbed layer detected by following the variation in the NMR parameters. The second chapter examines the process to obtain a plotted, data reduced Fourier transform NMR spectrum. This chapter highlights the pitfalls that can cause a decrease in information content in a NMR spectrum. The

  6. Magnetic Resonance Imaging with a Dielectric Lens

    CERN Document Server

    Vazquez, F; Martin, R; Rodriguez, A O

    2009-01-01

    Recently, metamaterials have been introduced to improve the signal-to-noise ratio (SNR) of magnetic resonance images with very promising results. However, the use polymers in the generation of high quality images in magnetic resonance imaging has not been fully been investigated. These investigations explored the use of a dielectric periodical array as a lens to improve the image SNR generated with single surface coils. Commercial polycarbonate glazing sheets were used together with a circular coil to generate phantom images at 3 Tesla on a clinical MR imager.

  7. The progress of coronary magnetic resonance imaging

    International Nuclear Information System (INIS)

    Coronary heart disease (CHD) is a kind of disease with high morbidity and mortality. The early detection and treatment has important significance to patient. With the features of noninvasive, no radiation, good soft tissue contrast and multi parameter, and displaying anatomy in arbitrary plane, magnetic resonance imaging (MRI) was gradually applied in coronary artery imaging. In this paper, the main sequence and scanning technology of coronary MRI were reviewed, factors that affecting the quality of coronary magnetic resonance imaging were summarized, and the main advantages and disadvantages were concluded. (authors)

  8. Nuclear magnetic resonance of thermally oriented nuclei

    International Nuclear Information System (INIS)

    The more recent developments in the spectroscopy of Nuclear Magnetic Resonance on Oriented Nuclei (NMRON) are reviewed; both theoretical and experimental advances are summarised with applications to On-Line and Off-Line determination of magnetic dipole and electric quadrupole hyperfine parameters. Some emphasis is provided on solid state considerations with indications of where likely enhancements in technique will lead in conventional hyperfine studies. (orig.)

  9. Multi-dimensionally encoded magnetic resonance imaging

    OpenAIRE

    Lin, Fa-Hsuan

    2012-01-01

    Magnetic resonance imaging typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image...

  10. Magnetic Resonance Imaging in Biomedical Engineering

    Science.gov (United States)

    Kaśpar, Jan; Hána, Karel; Smrčka, Pavel; Brada, Jiří; Beneš, Jiří; Šunka, Pavel

    2007-11-01

    The basic principles of magnetic resonance imaging covering physical principles and basic imaging techniques will be presented as a strong tool in biomedical engineering. Several applications of MRI in biomedical research practiced at the MRI laboratory of the FBMI CTU including other laboratory instruments and activities are introduced.

  11. Interactive Real-time Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Brix, Lau

    Real-time acquisition, reconstruction and interactively changing the slice position using magnetic resonance imaging (MRI) have been possible for years. However, the current clinical use of interactive real-time MRI is limited due to an inherent low spatial and temporal resolution. This PhD proje...

  12. Intralabyrinthine schwannoma shown by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Saeed, S.R. (Univ. Dept. of Otolaryngology, Manchester Royal Infirmary (United Kingdom)); Birzgalis, A.R. (Univ. Dept. of Otolaryngology, Manchester Royal Infirmary (United Kingdom)); Ramsden, R.T. (Univ. Dept. of Otolaryngology, Manchester Royal Infirmary (United Kingdom))

    1994-01-01

    Intralabyrinthine schwannomas are rare benign tumours which present with progressive or fluctuant audiovestibular symptoms and may mimic Menieres disease. The size and position of these lesions make preoperative diagnosis unusual and most are discovered incidentally at labyrinthectomy. A case is reported which was diagnosed on magnetic resonance imaging and confirmed at surgery. (orig.)

  13. Breast magnetic resonance imaging guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Bo La; Kim, Sun Mi; Jang, Mi Jung [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Cho, Nariya; Moon, Woo Kyung [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Hak Hee [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2016-06-15

    Despite the high sensitivity of breast magnetic resonance imaging (MRI), pathologic confirmation by biopsy is essential because of limited specificity. MRI-guided biopsy is required in patients with lesions only seen on MRI. We review preprocedural considerations and the technique of MRI-guided biopsy, challenging situations and trouble-shooting, and correlation of radiologic and pathologic findings.

  14. Sports health magnetic resonance imaging challenge.

    Science.gov (United States)

    Howell, Gary A; Stadnick, Michael E; Awh, Mark H

    2010-11-01

    Injuries to the Lisfranc ligament complex are often suspected, particularly in the setting of midfoot pain without radiographic abnormality. Knowledge of the anatomy and magnetic resonance imaging findings of injuries to this region is helpful for the diagnosing and treating physicians.

  15. Evaluation of nuclear magnetic resonance spectroscopy variability

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, Felipe Rodrigues; Salmon, Carlos Ernesto Garrido, E-mail: garrido@ffclrp.usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Filisofia, Ciencias e Letras; Otaduy, Maria Concepcion Garcia [Universidade de Sao Paulo (FAMUS/USP), Sao Paulo, SP (Brazil). Fac. de Medicina. Departamento de Radiologia

    2014-11-01

    Introduction: the intrinsically high sensitivity of Magnetic Resonance Spectroscopy (MRS) causes considerable variability in metabolite quantification. In this study, we evaluated the variability of MRS in two research centers using the same model of magnetic resonance image scanner. Methods: two metabolic phantoms were created to simulate magnetic resonance spectra from in vivo hippocampus. The phantoms were filled with the same basic solution containing the following metabolites: N-acetyl-aspartate, creatine, choline, glutamate, glutamine and inositol. Spectra were acquired over 15 months on 26 acquisition dates, resulting in a total of 130 spectra per center. Results: the phantoms did not undergo any physical changes during the 15-month period. Temporal analysis from both centers showed mean metabolic variations of 3.7% in acquisitions on the same day and of 8.7% over the 15-month period. Conclusion: The low deviations demonstrated here, combined with the high specificity of Magnetic Resonance Spectroscopy, confirm that it is feasible to use this technique in multicenter studies in neuroscience research. (author)

  16. Brain Morphometry Using Anatomical Magnetic Resonance Imaging

    Science.gov (United States)

    Bansal, Ravi; Gerber, Andrew J.; Peterson, Bradley S.

    2008-01-01

    The efficacy of anatomical magnetic resonance imaging (MRI) in studying the morphological features of various regions of the brain is described, also providing the steps used in the processing and studying of the images. The ability to correlate these features with several clinical and psychological measures can help in using anatomical MRI to…

  17. Use of Magnetic Resonance in Pancreaticobiliary Emergencies.

    Science.gov (United States)

    Bates, David D B; LeBedis, Christina A; Soto, Jorge A; Gupta, Avneesh

    2016-05-01

    This article presents the magnetic resonance protocols, imaging features, diagnostic criteria, and complications of commonly encountered emergencies in pancreaticobiliary imaging. Pancreatic trauma, bile leak, acute cholecystitis, biliary obstruction, and pancreatitis are discussed. Various classifications and complications that can arise with these conditions, as well as artifacts that may mimic pathology, are also included. PMID:27150328

  18. Magnetic resonance imaging in acute tendon ruptures

    Energy Technology Data Exchange (ETDEWEB)

    Daffner, R.H.; Lupetin, A.R.; Dash, N.; Riemer, B.L.

    1986-11-01

    The diagnosis of acute tendon ruptures of the extensor mechanism of the knee or the Achilles tendon of the ankle may usually be made by clinical means. Massive soft tissue swelling accompanying these injuries often obscures the findings, however. Magnetic resonance imaging (MRI) can rapidly demonstrate these tendon ruptures. Examples of the use of MRI for quadriceps tendon, and Achilles tendon rupture are presented.

  19. Nuclear Magnetic Resonance Technology for Medical Studies.

    Science.gov (United States)

    Budinger, Thomas F.; Lauterbur, Paul C.

    1984-01-01

    Reports on the status of nuclear magnetic resonance (NMR) from theoretical and clinical perspectives, reviewing NMR theory and relaxation parameters relevant to NMR imaging. Also reviews literature related to modern imaging strategies, signal-to-noise ratio, contrast agents, in vivo spectroscopy, spectroscopic imaging, clinical applications, and…

  20. Magnetic Resonance Lithography with Nanometer Resolution

    Directory of Open Access Journals (Sweden)

    Fahad AlGhannam

    2016-04-01

    Full Text Available We propose an approach for super-resolution optical lithography which is based on the inverse of magnetic resonance imaging (MRI. The technique uses atomic coherence in an ensemble of spin systems whose final state population can be optically detected. In principle, our method is capable of producing arbitrary one and two dimensional high-resolution patterns with high contrast.

  1. Evaluation of nuclear magnetic resonance spectroscopy variability

    International Nuclear Information System (INIS)

    Introduction: the intrinsically high sensitivity of Magnetic Resonance Spectroscopy (MRS) causes considerable variability in metabolite quantification. In this study, we evaluated the variability of MRS in two research centers using the same model of magnetic resonance image scanner. Methods: two metabolic phantoms were created to simulate magnetic resonance spectra from in vivo hippocampus. The phantoms were filled with the same basic solution containing the following metabolites: N-acetyl-aspartate, creatine, choline, glutamate, glutamine and inositol. Spectra were acquired over 15 months on 26 acquisition dates, resulting in a total of 130 spectra per center. Results: the phantoms did not undergo any physical changes during the 15-month period. Temporal analysis from both centers showed mean metabolic variations of 3.7% in acquisitions on the same day and of 8.7% over the 15-month period. Conclusion: The low deviations demonstrated here, combined with the high specificity of Magnetic Resonance Spectroscopy, confirm that it is feasible to use this technique in multicenter studies in neuroscience research. (author)

  2. Magnetic resonance imaging in radiotherapy treatment planning

    NARCIS (Netherlands)

    Moerland, Marinus Adriaan

    2001-01-01

    From its inception in the early 1970's up to the present, magnetic resonance imaging (MRI) has evolved into a sophisticated technique, which has aroused considerable interest in var- ious subelds of medicine including radiotherapy. MRI is capable of imaging in any plane and does not use ionizing rad

  3. Numerical methods in electron magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Soernes, A.R

    1998-07-01

    The focal point of the thesis is the development and use of numerical methods in the analysis, simulation and interpretation of Electron Magnetic Resonance experiments on free radicals in solids to uncover the structure, the dynamics and the environment of the system.

  4. Imaging Intelligence with Proton Magnetic Resonance Spectroscopy

    Science.gov (United States)

    Jung, Rex E.; Gasparovic, Charles; Chavez, Robert S.; Caprihan, Arvind; Barrow, Ranee; Yeo, Ronald A.

    2009-01-01

    Proton magnetic resonance spectroscopy ([to the first power]H-MRS) is a technique for the assay of brain neurochemistry "in vivo." N-acetylaspartate (NAA), the most prominent metabolite visible within the [to the first power]H-MRS spectrum, is found primarily within neurons. The current study was designed to further elucidate NAA-cognition…

  5. Cardiovascular magnetic resonance in systemic hypertension

    OpenAIRE

    Maceira Alicia M; Mohiaddin Raad H

    2012-01-01

    Abstract Systemic hypertension is a highly prevalent potentially modifiable cardiovascular risk factor. Imaging plays an important role in the diagnosis of underlying causes for hypertension, in assessing cardiovascular complications of hypertension, and in understanding the pathophysiology of the disease process. Cardiovascular magnetic resonance (CMR) provides accurate and reproducible measures of ventricular volumes, mass, function and haemodynamics as well as uniquely allowing tissue char...

  6. Interaction of magnetic resonators studied by the magnetic field enhancement

    Science.gov (United States)

    Hou, Yumin

    2013-12-01

    It is the first time that the magnetic field enhancement (MFE) is used to study the interaction of magnetic resonators (MRs), which is more sensitive than previous parameters-shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  7. Interaction of magnetic resonators studied by the magnetic field enhancement

    Directory of Open Access Journals (Sweden)

    Yumin Hou

    2013-12-01

    Full Text Available It is the first time that the magnetic field enhancement (MFE is used to study the interaction of magnetic resonators (MRs, which is more sensitive than previous parameters–shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  8. Interaction of magnetic resonators studied by the magnetic field enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Yumin, E-mail: ymhou@pku.edu.cn [State Key Laboratory for Mesoscopic Physics, School of Physics, Peking University, Beijing 100871 (China)

    2013-12-15

    It is the first time that the magnetic field enhancement (MFE) is used to study the interaction of magnetic resonators (MRs), which is more sensitive than previous parameters–shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  9. Quantification of synovistis by MRI: correlation between dynamic and static gadolinium-enhanced magnetic resonance imaging and microscopic and macroscopic signs of synovial inflammation

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Stoltenberg, M; Løvgreen-Nielsen, P;

    1998-01-01

    Dynamic and static gadolinium-diethylenetriaminepentaacetic acid(Gd-DTPA)-enhanced magnetic resonance imaging (MRI) were evaluated as measures of joint inflammation in arthritis, by a comparison with macroscopic and microscopic signs of synovitis. Furthermore, the importance of the size of the ev......Dynamic and static gadolinium-diethylenetriaminepentaacetic acid(Gd-DTPA)-enhanced magnetic resonance imaging (MRI) were evaluated as measures of joint inflammation in arthritis, by a comparison with macroscopic and microscopic signs of synovitis. Furthermore, the importance of the size...

  10. Magnetic resonance imaging of infectious myositis

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha [The Catholic Univ., College of Medicine, Suwon (Korea, Republic of)

    1998-09-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  11. The working principle of magnetic resonance therapy

    CERN Document Server

    Brizhik, Larissa; Fermi, Enrico

    2015-01-01

    In this paper we describe briefly the basic aspects of magnetic resonance therapy, registered as TMR therapy. Clinical studies have shown that application of this therapy significantly accelerates wound healing and, in particular, healing of the diabetic foot disease. To understand the working principle of this therapy, we analyze relevant to it biological effects produced by magnetic fields. Based on these data, we show that there is a hierarchy of the possible physical mechanisms, which can produce such effects. The mutual interplay between the mechanisms can lead to a synergetic outcome delayed in time, which can affect the physiological state of the organism. In particular, we show that soliton mediated charge transport during the redox processes in living organisms is sensitive to magnetic fields, so that such fields can facilitate redox processes in particular, and can stimulate the healing effect of the organism in general. This and other non-thermal resonant mechanisms of the biological effects of mag...

  12. Nuclear magnetic resonance properties of lunar samples.

    Science.gov (United States)

    Kline, D.; Weeks, R. A.

    1972-01-01

    Nuclear magnetic resonance spectra of Na-23, Al-27, and P-31 in fines samples 10084,60 and 14163,168 and in crystalline rock samples 12021,55 and 14321,166, have been recorded over a range of frequencies up to 20 MHz. A shift in the field at which maximum absorption occurs for all of the spectra relative to the field at which maximum absorption occurs for terrestrial analogues is attributed to a sample-dependent magnetic field at the Na, Al, and P sites opposing the laboratory field. The magnitude of these fields internal to the samples is sample dependent and varies from 5 to 10 G. These fields do not correlate with the iron content of the samples. However, the presence of single-domain particles of iron distributed throughout the plagioclase fraction that contains the principal fraction of Na and Al is inferred from electron magnetic resonance spectra shapes.

  13. Magnetic Earth Ionosphere Resonant Frequencies

    Science.gov (United States)

    Spaniol, Craig

    1994-01-01

    The Community College Division is pleased to report progress of NASA funded research at West Virginia State College. During this reporting period, the project research group has continued with activities to develop instrumentation capability designed to monitor resonant cavity frequencies in the atmospheric region between the Earth's surface and the ionosphere. In addition, the project's principal investigator, Dr. Craig Spaniol, and NASA technical officer, Dr. John Sutton, have written and published technical papers intended to expand the scientific and technical framework needed for project research. This research continues to provide an excellent example of government and education working together to provide significant research in the college environment. This cooperative effort has provided many students with technical project work which compliments their education.

  14. Magnetic resonance imaging by using nano-magnetic particles

    Energy Technology Data Exchange (ETDEWEB)

    Shokrollahi, H., E-mail: Shokrollahi@sutech.ac.ir [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Khorramdin, A. [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Isapour, Gh. [Department of Materials and Engineering, Hakim Sabzevari University (Iran, Islamic Republic of)

    2014-11-15

    Magnetism and magnetic materials play a major role in various biological applications, such as magnetic bioseparation, magnetic resonance imaging (MRI), hyperthermia treatment of cancer and drug delivery. Among these techniques, MRI is a powerful method not only for diagnostic radiology but also for therapeutic medicine that utilizes a magnetic field and radio waves. Recently, this technique has contributed greatly to the promotion of the human quality life. Thus, this paper presents a short review of the physical principles and recent advances of MRI, as well as providing a summary of the synthesis methods and properties of contrast agents, like different core materials and surfactants. - Highlights: • This paper studies the physics of MRI as a powerful diagnostic technique. • MRI uses the differentiation between healthy and pathological tissues. • The relaxation times can be shortened by the use of a magnetic contrast agent. • The magnetic nanoparticles act as contrast agents, helping to increase the resolution. • Different synthesis methods can influence the magnetic resonance behavior.

  15. Nuclear magnetic resonance (NMR): principles and applications

    International Nuclear Information System (INIS)

    The basis for the phenomenon of nuclear magnetic resonance (NMR) is the ability of certain nuclei possessing both intrinsic angular momentum or ''spin'' I and magnetic moment to absorb electromagnetic energy in the radio frequency range. In principle, there are approximately 200 nuclei which may be investigated using the NMR technique. The NMR spectrum consists of intensity peaks along an axis calibrated in terms of the steady magnetic field or the frequency of the radiofrequency electromagnetic radiation. Analysis of the number, spacing, position and intensity of the lines in an NMR spectrum consists of intensity peaks along an axis calibrated in terms of the steady magnetic field or the frequency of the radiofrequency electromagnetic radiation. Analysis of the number, spacing, position and intensity of the lines in an NMR spectrum provides a variety of qualitative and quantitative analytical applications. The most obvious applications consist of the measurements of nuclear properties, such as spin number and nuclear magnetic moment. In liquids, the fine structure of resonance spectra provides a tool for chemical identification and molecular structure analysis. Other applications include the measurements of self-diffusion coefficients, magnetic fields and field homogeneity, inter-nuclear distances, and, in some cases, the water content of biological materials. (author)

  16. 21 CFR 892.1000 - Magnetic resonance diagnostic device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Magnetic resonance diagnostic device. 892.1000... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1000 Magnetic resonance diagnostic device. (a) Identification. A magnetic resonance diagnostic device is intended for general diagnostic...

  17. Advances in magnetic and optical resonance

    CERN Document Server

    Warren, Warren S

    2013-01-01

    Advances in Magnetic and Optical Resonance contains three articles which review quite fundamentally different aspects of coherent spectroscopy. An enormous variety of effects can be observed when optical and spin resonances are coupled, usually by a combination of radio frequency and laser irradiation. The first article reviews these effects and pays particular attention to developing a theoretical framework which is as similar as possible for the optical and spin cases. Subsequent articles examine deuterium relaxation in molecular solids, and the spatiotemporal growth of multiple spin coheren

  18. Validation of the OMERACT Magnetic Resonance Imaging Joint Space Narrowing Score for the Wrist in a Multireader Longitudinal Trial

    DEFF Research Database (Denmark)

    Glinatsi, Daniel; Lillegraven, Siri; Haavardsholm, Espen A;

    2015-01-01

    OBJECTIVE: To assess the intrareader and interreader agreement and sensitivity to change of the Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis Magnetic Resonance Imaging Joint Space Narrowing (RAMRIS-JSN) score in the rheumatoid arthritis (RA) wrist in a longitudinal multireader...... exercise. METHODS: Coronal T1-weighted MR image sets of 1 wrist from 20 patients with early RA were assessed twice for JSN at 17 sites at baseline and after 36 or 60 months by 4 readers blinded to patient data but not time order. The joints were scored 0-4 according to the OMERACT RAMRIS-JSN score...

  19. A hyperpolarized equilibrium for magnetic resonance

    Science.gov (United States)

    Hövener, Jan-Bernd; Schwaderlapp, Niels; Lickert, Thomas; Duckett, Simon B.; Mewis, Ryan E.; Highton, Louise A. R.; Kenny, Stephen M.; Green, Gary G. R.; Leibfritz, Dieter; Korvink, Jan G.; Hennig, Jürgen; von Elverfeldt, Dominik

    2013-12-01

    Nuclear magnetic resonance spectroscopy and imaging (MRI) play an indispensable role in science and healthcare but use only a tiny fraction of their potential. No more than ≈10 p.p.m. of all 1H nuclei are effectively detected in a 3-Tesla clinical MRI system. Thus, a vast array of new applications lays dormant, awaiting improved sensitivity. Here we demonstrate the continuous polarization of small molecules in solution to a level that cannot be achieved in a viable magnet. The magnetization does not decay and is effectively reinitialized within seconds after being measured. This effect depends on the long-lived, entangled spin-order of parahydrogen and an exchange reaction in a low magnetic field of 10-3 Tesla. We demonstrate the potential of this method by fast MRI and envision the catalysis of new applications such as cancer screening or indeed low-field MRI for routine use and remote application.

  20. Thin layer and nuclear magnetic resonance magnetometers

    International Nuclear Information System (INIS)

    In the first part of this text, magnetometers with sensitive elements in the form of thin cylindrical ferromagnetic layers are described. These layers are anisotropic, uniaxial, C orientated and single domains. In the second part of the text, the principles of the nuclear magnetic resonance magnetometer realized at the LETI are presented. This instrument is accurate, of high efficiency, and isotropic. Very small variations in magnetic field intensity (10-7 oersteds) can be detected with a 1Hz pass band at zero frequency

  1. Magnetic resonance semiotics of breast fibroadenomas

    Directory of Open Access Journals (Sweden)

    S. V. Serebryakova

    2010-01-01

    Full Text Available Various benign breast abnormalities are diagnosed in 60% of women in Russia today. This is associated with failure of preoperative recognition of the histological class of an identified nodular mass – its detection is an indication for surgical treatment. By using 67 histologically verified breast fibroadenomas (FA as an example, the authors describe their magnetic resonance semiotics and present the differential diagnostic criteria used during dynamic contrast-enhanced magnetic resonance mammography. FAs are characterized by well-defined uniform outlines, homogeneous internal structure, centrifugal and homogeneous accumulation of contrast media through- out the study, without deforming the breast vasculature around. One of the criteria that permit differential diagnosis of FA with malignan- cies is their estimated vascularization.

  2. Sensorineural hearing loss after magnetic resonance imaging

    DEFF Research Database (Denmark)

    Mollasadeghi, Abolfazl; Mehrparvar, Amir Houshang; Atighechi, Saeid;

    2013-01-01

    Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus)......). In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient's hearing loss was accompanied with tinnitus and was not improved after 3 months of followup.......Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus...

  3. Contribution of magnetic resonance imaging in rheumatology

    Energy Technology Data Exchange (ETDEWEB)

    Lavieille, J.; Amalric, R.; Stanoyevitch, J.F.; Hopf, M.A.; Antipoff, G.M.; Roux, H.

    1986-11-01

    The authors report their experience with magnetic resonance imaging in rheumatology, established on more than 250 examinations. The method seems interesting for the study of discal and somatic spine diseases, and especially for the evaluation of tumor extension, the diagnosis of herniated disc, the diagnosis of spondylodiscitis, the exploration of the cervico-occipital joint. As compared to tomodensitometry, this method presents at the same time advantages and drawbacks. Peripherally, magnetic resonance imaging is useful for the exploration of bony tumors and evaluation of their extension. It gives excellent images of the knees and the hips where it seems to improve the results of tomodensitometry and bony scintigraphy in the diagnosis of osteonecrosis. It is likely that advances will broaden the scope of the indications and capabilities of this method.

  4. Magnetic resonance imaging findings in tuberculous meningoencephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Pui, M.H.; Memon, W.A. [Aga Khan Univ. Hospital, Dept. of Radiology, Karachi (Pakistan)

    2001-02-01

    To evaluate the efficacy of magnetic resonance imaging (MRI) for distinguishing tuberculosis from other types of meningoencephalitis. MRIs of 100 patients with tuberculous (50), pyogenic (33), viral (14), or fungal (3) meningoencephalitis were analyzed independently by 2 radiologists. Number, size, location, signal characteristics, surrounding edema, and contrast enhancement pattern of nodular lesions; location and pattern of meningeal enhancement; extent of infarct or encephalitis and hydrocephalus were evaluated. Contrast-enhancing nodular lesions were detected in patients with tuberculous (43 of 50 patients), pyogenic (9 of 33), and fungal (3 of 3) infections. No nodules were detected in patients with viral meningoencephalitis. Using the criteria of 1 or more solid rim or homogeneously enhancing nodules smaller than 2 cm, the sensitivity, specificity and accuracy for diagnosing tuberculous meningitis were 86.0%, 90.0% and 88.0%, respectively. Magnetic resonance imaging is useful in distinguishing tuberculous from pyogenic, viral and fungal meningoencephalitis. (author)

  5. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.;

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper review...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8......Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...

  6. High speed functional magnetic resonance imaging

    CERN Document Server

    Gibson, A M

    2002-01-01

    The work in this thesis has been undertaken by the except where indicated by reference, within the Magnetic Resonance Centre at the University of Nottingham during the period from October 1998 to October 2001. This thesis documents the implementation and application of a novel high-speed imaging technique, the multi-slice, echo shifted, echo planar imaging technique. This was implemented on the Nottingham 3 T imaging system, for functional magnetic resonance imaging. The technique uses echo shifting over the slices in a multi-slice echo planar imaging acquisition scheme, making the echo time longer than the repetition time per slice. This allows for rapid volumar sampling of the blood oxygen level dependent effect in the human brain. The new high-speed technique was used to investigate the variability of measuring the timing differences between haemodynamic responses, at the same cortical location, to simple cued motor tasks. The technique was also used in an investigation into motor cortex functional connect...

  7. Female pelvic anatomy: magnetic resonance study

    International Nuclear Information System (INIS)

    The potential of magnetic resonance imaging was evaluated in this study. Conventional imaging methods like sonography and X-ray computerised tomography generally provide accurate data. Magnetic resonance imaging appears to be very suitable for studying the pelvis because it has the capacity to produce direct multidirectional images. By recording alterations in T1 and T2 values, it provides a wide range of information. A 1.5 T imaging system was used. Pulse sequences used always included T1 and T2 weighted spin-echo scans. The T2 scan was performed in the best plane for the organ of interest. The comparison between these different acquisitions provides good tissue differentiation. Results of 73 studies are exposed

  8. Magnetic resonance imaging for acute pancreatitis

    OpenAIRE

    Xiao, Bo; Zhang, Xiao-Ming

    2010-01-01

    Acute pancreatitis is characterized by acute chemical injury of the pancreatic parenchyma and peripancreatic tissue. The increased frequency of death in acute pancreatitis is directly correlated with the degree and progress of pancreatic necrosis. Moreover, the occurrence of some local complications in acute pancreatitis, such as pancreatic hemorrhage, peripancreatic abscess or large pseudocyst, and pseudoaneurysm, could influence the choice of treatment for these patients. Magnetic resonance...

  9. Perfusion magnetic resonance imaging of the liver

    Institute of Scientific and Technical Information of China (English)

    Choon; Hua; Thng; Tong; San; Koh; David; J; Collins; Dow; Mu; Koh

    2010-01-01

    Perfusion magnetic resonance imaging (MRI) studies quantify the microcirculatory status of liver parenchyma and liver lesions, and can be used for the detection of liver metastases, assessing the effectiveness of antiangiogenic therapy, evaluating tumor viability after anticancer therapy or ablation, and diagnosis of liver cirrhosis and its severity. In this review, we discuss the basic concepts of perfusion MRI using tracer kinetic modeling, the common kinetic models applied for analyses, the MR scanning t...

  10. "PALPATION BY IMAGING": MAGNETIC RESONANCE ELASTOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    Lei Xu; Pei-yi Gao

    2006-01-01

    Elasticity is an important physical property of human tissues.There is a tremendous difference in elasticity between normal and pathological tissues.Noninvasive evaluation of the elasticity of human tissues would be valuable for clinical practice.Magnetic resonance elastography(MRE)is a recently developed noninvasive imaging technique that can directly visualize and quantitatively measure tissue elasticity.This article reviewed the MRE technique and its current status.

  11. Magnetic Resonance Elastography: Inversions in Bounded Media

    OpenAIRE

    Kolipaka, Arunark; McGee, Kiaran P.; Manduca, Armando; Romano, Anthony J; Glaser, Kevin J.; Araoz, Philip A; Ehman, Richard L.

    2009-01-01

    Magnetic resonance elastography (MRE) is a noninvasive imaging technique capable of quantifying and spatially resolving the shear stiffness of soft tissues by visualization of synchronized mechanical wave displacement fields. However, MRE inversions generally assume that the measured tissue motion consists primarily of shear waves propagating in a uniform, infinite medium. This assumption is not valid in organs such as the heart, eye, bladder, skin, fascia, bone and spinal cord in which the s...

  12. Magnetic resonance imaging of pancreatitis: An update

    OpenAIRE

    Manikkavasakar, Sriluxayini; AlObaidy, Mamdoh; Busireddy, Kiran K; Ramalho, Miguel; Nilmini, Viragi; Alagiyawanna, Madhavi; Semelka, Richard C

    2014-01-01

    Magnetic resonance (MR) imaging plays an important role in the diagnosis and staging of acute and chronic pancreatitis and may represent the best imaging technique in the setting of pancreatitis due to its unmatched soft tissue contrast resolution as well as non-ionizing nature and higher safety profile of intravascular contrast media, making it particularly valuable in radiosensitive populations such as pregnant patients, and patients with recurrent pancreatitis requiring multiple follow-up ...

  13. Cardiovascular magnetic resonance in carotid atherosclerotic disease

    OpenAIRE

    Chen Huijun; Wang Jinnan; Li Rui; Ferguson Marina S; Kerwin William S; Dong Li; Canton Gador; Hatsukami Thomas S; Yuan Chun

    2009-01-01

    Abstract Atherosclerosis is a chronic, progressive, inflammatory disease affecting many vascular beds. Disease progression leads to acute cardiovascular events such as myocardial infarction, stroke and death. The diseased carotid alone is responsible for one third of the 700,000 new or recurrent strokes occurring yearly in the United States. Imaging plays an important role in the management of atherosclerosis, and cardiovascular magnetic resonance (CMR) of the carotid vessel wall is one promi...

  14. Myocardial tissue tagging with cardiovascular magnetic resonance

    OpenAIRE

    Bluemke David A; Osman Nael F; Cheng Susan; Shehata Monda L; Lima João AC

    2009-01-01

    Abstract Cardiovascular magnetic resonance (CMR) is currently the gold standard for assessing both global and regional myocardial function. New tools for quantifying regional function have been recently developed to characterize early myocardial dysfunction in order to improve the identification and management of individuals at risk for heart failure. Of particular interest is CMR myocardial tagging, a non-invasive technique for assessing regional function that provides a detailed and compreh...

  15. Cardiovascular magnetic resonance in pulmonary hypertension

    OpenAIRE

    Bradlow William M; R Gibbs J Simon; Mohiaddin Raad H

    2012-01-01

    Abstract Pulmonary hypertension represents a group of conditions characterized by higher than normal pulmonary artery pressures. Despite improved treatments, outcomes in many instances remain poor. In recent years, there has been growing interest in the use of Cardiovascular Magnetic Resonance (CMR) in patients with pulmonary hypertension. This technique offers certain advantages over other imaging modalities since it is well suited to the assessment of the right ventricle and the proximal pu...

  16. Quantitative cardiovascular magnetic resonance for molecular imaging

    OpenAIRE

    Lanza Gregory M; Caruthers Shelton D; Winter Patrick M; Wickline Samuel A

    2010-01-01

    Abstract Cardiovascular magnetic resonance (CMR) molecular imaging aims to identify and map the expression of important biomarkers on a cellular scale utilizing contrast agents that are specifically targeted to the biochemical signatures of disease and are capable of generating sufficient image contrast. In some cases, the contrast agents may be designed to carry a drug payload or to be sensitive to important physiological factors, such as pH, temperature or oxygenation. In this review, examp...

  17. Functional magnetic resonance imaging in schizophrenia

    OpenAIRE

    Gur, Raquel E.; Gur, Ruben C.

    2010-01-01

    The integration of functional magnetic resonance imaging (fMRI) with cognitive and affective neuroscience paradigms enables examination of the brain systems underlying the behavioral deficits manifested in schizophrenia; there have been a remarkable increase in the number of studies that apply fMRI in neurobiological studies of this disease. This article summarizes features of fMRI methodology and highlights its application in neurobehavioral studies in schizophrenia. Such work has helped elu...

  18. Cardiovascular magnetic resonance imaging - a pictorial review

    OpenAIRE

    Vijay Dahya; Spottiswoode, Bruce S.

    2010-01-01

    Cardiovascular magnetic resonance imaging (CMR) is a powerful problem-solving tool and arguably offers the most comprehensive assessment of cardiac morphology and function, as well as the opportunity of rebuilding the bridge between cardiologists and radiologists. The role of CMR-trained imaging physicists is also valuable, and many CMR centres harmoniously incorporate these three sub-specialty fields. This paper comprises an overview of several CMR techniques, outlining both the strengths...

  19. Cardiovascular magnetic resonance imaging - a pictorial review

    Directory of Open Access Journals (Sweden)

    Vijay Dahya

    2010-12-01

    Full Text Available Cardiovascular magnetic resonance imaging (CMR is a powerful problem-solving tool and arguably offers the most comprehensive assessment of cardiac morphology and function, as well as the opportunity of rebuilding the bridge between cardiologists and radiologists. The role of CMR-trained imaging physicists is also valuable, and many CMR centres harmoniously incorporate these three sub-specialty fields. This paper comprises an overview of several CMR techniques, outlining both the strengths and limitations of the modality.

  20. Waveguide volume probe for magnetic resonance imaging and spectroscopy

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to a probe for use within the field of nuclear magnetic resonance, such as magnetic resonance imaging (MRI), and magnetic resonance spectroscopy (MRS)). One embodiment relates to an RF probe for magnetic resonance imaging and/or spectroscopy comprising a conductive...... non-magnetic hollow waveguide having an internal volume and at least one open end, one or more capacitors and at least a first conductive non-magnetic wire, wherein said first conductive wire connects at least one of said one or more capacitors to opposite walls of one open end of the waveguide...

  1. Significance of anti-cyclic citrullinated peptide antibody and magnetic resonance imaging of metacarpophalangeal joints and wrist in early rheumatoid arthritis%抗环瓜氨酸肽抗体和关节磁共振成像对早期类风湿关节炎的意义

    Institute of Scientific and Technical Information of China (English)

    岳涛; 程鹏; 范晓蕾; 孙红梅; 周嘉陵; 何东仪; 陈继红; 张湛明

    2011-01-01

    目的 研究抗环瓜氨酸肽抗体(抗CCP)和核磁共振成像(MRI)对早期类风湿关节炎(RA)的诊断价值.方法 2007年1月至2009年6月上海光华医院对早期RA组 94例、不典型单关节炎组24例及对照组35例行掌指关节及腕关节MR扫描.同时搜集患者的临床资料及抗CCP抗体、类风湿因子(RF-IgM)等实验室指标.统计并分析MRI征象及OMERACT评分同临床检查之间的关系.结果 抗CCP抗体在早期RA中敏感性55.3%,特异性88.6%.根据MRI所示,滑膜增生对早期RA的敏感性和特异性分别为100%、71.4%;骨髓水肿为25.5%、94.3%;骨侵蚀为88.3%、65.7%.其中骨髓水肿的特异性最高,表现出骨髓水肿与抗CCP抗体阳性有一定关联.关节MRI对于早期RA有很高的诊断价值,对于骨破坏及滑膜炎的的敏感性远高于传统X线检查.与掌指关节相比,腕关节的MRI骨破坏更明显.结论 早期RA的腕骨骨髓水肿与抗CCP抗体阳性相关,抗CCP抗体和MRI对于早期RA的特异性均较高,分别优于RF与X线平片,有利于RA的早期诊断.二者联合检查能减少早期RA的漏诊率.%Objective To study the diagnostic value of anti-cyclic citrullinated peptide antibody (anti-CCP) and magnetic resonance imaging (MRI) of metacarpophalangeal joints(MCP)and wrist in early rheumatoid arthritis(RA).Methods MRI of MCP and wrist joint, laboratory indices of anti-CCP and rheumatic factor (RF) were performed and recorded in the 94 early-stage RA patients, 24 non-typical monoarthritis and 35 other arthritis.The MRI findings and OMERACT (outcome measures in rheumatoid arthritis clinical trials) score were analyzed in comparison with their clinical and laboratory indices.Results The sensitivity of anti-CCP, synonitis, bone erosion and bone erosion was 55.3%, 100%, 25.5% and 88.3% respectively in early-stage RA patients.The specificity was 88.6%, 71.4%, 94.3% and 65.7% respectively.There was significant difference between early-stage RA group and other

  2. Electro-Mechanical Resonant Magnetic Field Sensor

    CERN Document Server

    Temnykh, A B; Temnykh, Alexander B.; Lovelace, Richard V. E.

    2002-01-01

    We describe a new type of magnetic field sensor which is termed an Electro-Mechanical Resonant Sensor (EMRS). The key part of this sensor is a small conductive elastic element with low damping rate and therefore a high Q fundamental mode of frequency $f_1$. An AC current is driven through the elastic element which, in the presence of a magnetic field, causes an AC force on the element. When the frequency of the AC current matches the resonant frequency of the element, maximum vibration of the element occurs and this can be measured precisely by optical means. We have built and tested a model sensor of this type using for the elastic element a length of copper wire of diameter 0.030 mm formed into a loop shape. The wire motion was measured using a light emitting diode photo-transistor assembly. This sensor demonstrated a sensitivity better than 0.001G for an applied magnetic field of $ \\sim 1$G and a good selectivity for the magnetic field direction. The sensitivity can be easily improved by a factor of $\\sim ...

  3. The diagnostic value of magnetic resonance imaging combined with anti-cyclic citrullinated peptide antibody in early rheumatoid arthritis%磁共振成像联合抗环瓜氨酸肽抗体对早期类风湿关节炎的诊断价值

    Institute of Scientific and Technical Information of China (English)

    范智斌; 张建新; 王峻; 温鸿雁

    2012-01-01

    Objective To investigate the diagnostic value of magnetic resonance imaging (MRI) combined with anti-cyclic citrullinated peptide (CCP) antibody for early rheumatoid arthritis (RA). Methods Eighty-three patients with polyarthritis (male: n=12, female: n=71) underwent MR scanning of the hands and wrists. All MR imaging was performed using spin echo (SE) and short time inversion recovery (STIR) sequences. Anti-CCP serum levels of patients were determined by ELISA. Results During the first visit and the regular checkups, 69 patients met the diagnostic criteria of ACR and were confirmed with RA. Notably, 51 patients (74%) with positive anti-CCP antibody. MRI showed 43 RA patients with synovitis. Notably, there were 38 cases of bone marrow edema and 29 cases of bone destruction in the synovitis group. Conclusion MRI scanning combined with detection of anti-CCP antibody may be helpful in the early diagnosis of RA.%目的 结合血清抗环瓜氨酸肽(CCP)抗体的水平研究磁共振成像(MRI)对类风湿关节炎(RA)手关节病变的诊断价值.方法 收集符合多关节肿痛患者83例,男12例,女71例,行双手及双腕关节MRI扫描,均采用自旋回波(SE)、短时反转恢复(STIR)序列.采用酶联免疫吸附试验(ELISA)测定患者血清抗CCP抗体的水平.结果 初诊及随诊中病情进展达到美国风湿病学会(ACR)RA诊断标准可确诊的患者69例,其中抗CCP抗体阳性者51例,阳性率为74%.43例RA患者MRI显示滑膜炎,其中,滑膜炎组38例有骨髓水肿,29例有骨质破坏.结论 MRI扫描结合抗CCP抗体检测有助于RA的早期诊断.

  4. Magnetic resonance imaging of the joints: a revolution for the practicing rheumatologist

    Directory of Open Access Journals (Sweden)

    M.A. Cimmino

    2011-09-01

    Full Text Available In the last 15 years, new imaging techniques have changed the life of practicing rheumatologists in terms of both diagnostic approach and knowledge of disease mechanisms. Clinical symptoms, disease signs and the results of physical examination have been more closely related to their anatomical basis. In particular, magnetic resonance imaging allow diagnosis of disease in its early phase and its follow-up with a previously unknown sensitivity. Novel imaging studies have contributed to elucidate several pathogenetic mechanisms in musculoskeletal diseases, such as rheumatoid arthritis, psoriatic arthritis, ankylosing spondylitis, polymyalgia rheumatica and osteoarthritis; allow evaluation of the real degree of joint inflammation, which is often uncoupled from clinical signs; and possibly reduce the need for large clinical trials. In conclusion, new imaging techniques and refinements of the established techniques have opened exciting perspectives in our understanding and treatment of many rheumatic diseases. Much attention should be paid to the training of new generations of rheumatologists in this field.

  5. Compact low field magnetic resonance imaging magnet: Design and optimization

    Science.gov (United States)

    Sciandrone, M.; Placidi, G.; Testa, L.; Sotgiu, A.

    2000-03-01

    Magnetic resonance imaging (MRI) is performed with a very large instrument that allows the patient to be inserted into a region of uniform magnetic field. The field is generated either by an electromagnet (resistive or superconductive) or by a permanent magnet. Electromagnets are designed as air cored solenoids of cylindrical symmetry, with an inner bore of 80-100 cm in diameter. In clinical analysis of peripheral regions of the body (legs, arms, foot, knee, etc.) it would be better to adopt much less expensive magnets leaving the most expensive instruments to applications that require the insertion of the patient in the magnet (head, thorax, abdomen, etc.). These "dedicated" apparati could be smaller and based on resistive magnets that are manufactured and operated at very low cost, particularly if they utilize an iron yoke to reduce power requirements. In order to obtain good field uniformity without the use of a set of shimming coils, we propose both particular construction of a dedicated magnet, using four independently controlled pairs of coils, and an optimization-based strategy for computing, a posteriori, the optimal current values. The optimization phase could be viewed as a low-cost shimming procedure for obtaining the desired magnetic field configuration. Some experimental measurements, confirming the effectiveness of the proposed approach (construction and optimization), have also been reported. In particular, it has been shown that the adoption of the proposed optimization based strategy has allowed the achievement of good uniformity of the magnetic field in about one fourth of the magnet length and about one half of its bore. On the basis of the good experimental results, the dedicated magnet can be used for MRI of peripheral regions of the body and for animal experimentation at very low cost.

  6. First national meeting of magnetic resonance and hyperfine interactions

    International Nuclear Information System (INIS)

    Works performed at CNEA's: Magnetic Resonance Division; Moessbauer Spectroscopy; Solid State Physics Division; Nuclear magnetic Resonance Laboratory and Theoretical Physics Group; Mossbauer Spectroscopy Group; Nuclear Quadrupole Resonance; Physics and Materials Group; Perturbed Angular Correlation and Moessbauer Spectroscopy and Physics Department. (M.E.L.)

  7. Effect of intraarticular osmic acid on synovial membrane volume and inflammation, determined by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Stoltenberg, M; Gideon, P;

    1995-01-01

    The changes in MR-determined synovial membrane volume, early synovial enhancement, and cartilage and bone erosions after osmic acid knee synovectomy were studied. Gadolinium-DTPA enhanced magnetic resonance imaging (MRI) of 18 knees with persistent arthritis was performed before and 1 month after...... treatment. The synovial membrane volume was significantly reduced (median -52%) in all 9 patients brought into clinical remission (p < 0.01), while no significant change was found in patients with clinical relapse. The early synovial enhancement was not significantly changed. MRI revealed progressive...

  8. Nuclear magnetic resonance imaging in brain tumors

    International Nuclear Information System (INIS)

    Full text: Magnetic resonance imaging (MRI) is a non-invasive imaging method based on the detecting signal from hydrogen nuclei of water molecules and fat. Performances of MRI are continuously increasing, and its domains of investigation of the human body are growing in both morphological and functional study. MRI also allows It also performing advanced management of tumours especially in the brain, by combining anatomical information (morphological MRI), functional (diffusion, perfusion and BOLD contrast) and metabolic (tissue composition in magnetic resonance spectroscopy (MRS)). The MRI techniques have an important role in cancerology. These techniques allow essential information for the diagnosis and answering therapist's questions before, during or after the treatment. The MR allows clarifying the localization of expanding processes, the differential diagnosis between brain tumour and a lesion confined by another structural aspect, the diagnosis of the tumoral aspect of a lesion, the histological ranking in case of glial tumour and the extension of its localization as well as the therapeutic follow-up (pre-therapeutic and post-therapeutics assessments). A better combination between the morphological, functional and metabolic studies, as well as integrating new technical developments, especially while using a multichannel bird cage coils the 3T magnet and suitable computing software, would allow significant improvements of the exploration strategies and management of brain tumors.

  9. Magnetic resonance imaging of valvular heart disease

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Ståhlberg, F; Thomsen, C

    1999-01-01

    The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used...... in an integrated approach to gain qualitative and quantitative information on valvular heart disease as well as ventricular dimensions and functions. Thus, MRI may be advantageous to the established diagnostic tools in assessing the severity of valvular heart disease as well as monitoring the lesion and predicting...... the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638....

  10. Nanodiamond graphitization: a magnetic resonance study

    International Nuclear Information System (INIS)

    We report on the first nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR) study of the high-temperature nanodiamond-to-onion transformation. 1H, 13C NMR and EPR spectra of the initial nanodiamond samples and those annealed at 600, 700, 800 and 1800 ° C were measured. For the samples annealed at 600 to 800 ° C, our NMR data reveal the early stages of the surface modification, as well as a progressive increase in sp2 carbon content with increased annealing temperature. Such quantitative experimental data were recorded for the first time. These findings correlate with EPR data on the sensitivity of the dangling bond EPR line width to air content, progressing with rising annealing temperature, that evidences consequent graphitization of the external layers of the diamond core. The sample annealed at 1800 ° C shows complete conversion of nanodiamond particles into carbon onions. (paper)

  11. Molecular structure and motion in zero field magnetic resonance

    International Nuclear Information System (INIS)

    Zero field magnetic resonance is well suited for the determination of molecular structure and the study of motion in disordered materials. Experiments performed in zero applied magnetic field avoid the anisotropic broadening in high field nuclear magnetic resonance (NMR) experiments. As a result, molecular structure and subtle effects of motion are more readily observed

  12. Magnetic Field Gradient Calibration as an Experiment to Illustrate Magnetic Resonance Imaging

    Science.gov (United States)

    Seedhouse, Steven J.; Hoffmann, Markus M.

    2008-01-01

    A nuclear magnetic resonance (NMR) spectroscopy experiment for the undergraduate physical chemistry laboratory is described that encompasses both qualitative and quantitative pedagogical goals. Qualitatively, the experiment illustrates how images are obtained in magnetic resonance imaging (MRI). Quantitatively, students experience the…

  13. Cardiovascular magnetic resonance in systemic hypertension

    Directory of Open Access Journals (Sweden)

    Maceira Alicia M

    2012-06-01

    Full Text Available Abstract Systemic hypertension is a highly prevalent potentially modifiable cardiovascular risk factor. Imaging plays an important role in the diagnosis of underlying causes for hypertension, in assessing cardiovascular complications of hypertension, and in understanding the pathophysiology of the disease process. Cardiovascular magnetic resonance (CMR provides accurate and reproducible measures of ventricular volumes, mass, function and haemodynamics as well as uniquely allowing tissue characterization of diffuse and focal fibrosis. In addition, CMR is well suited for exclusion of common secondary causes for hypertension. We review the current and emerging clinical and research applications of CMR in hypertension.

  14. Nuclear magnetic resonance common laboratory, quadrennial report

    International Nuclear Information System (INIS)

    This quadrennial report of the nuclear magnetic resonance common laboratory gives an overview of the main activities. Among the different described activities, only one is interesting for the INIS database: it concerns the Solid NMR of cements used for radioactive wastes storage. In this case, the NMR is used to characterize the structure of the material and the composition, structure and kinetics of formation of the alteration layer which is formed at the surface of concrete during water leaching conditions. The NMR methodology is given. (O.M.)

  15. Cardiac magnetic resonance in clinical cardiology

    Institute of Scientific and Technical Information of China (English)

    Andreas; Kumar; Rodrigo; Bagur

    2015-01-01

    Over the last decades, cardiac magnetic resonance(CMR) has transformed from a research tool to a widely used diagnostic method in clinical cardiology. This method can now make useful, unique contributions to the work-up of patients with ischemic and non-ischemic heart disease. Advantages of CMR, compared to other imaging methods, include very high resolution imaging with a spatial resolution up to 0.5 mm × 0.5 mm in plane, a large array of different imaging sequences to provide in vivo tissue characterization, and radiationfree imaging. The present manuscript highlights the relevance of CMR in the current clinical practice and new perspectives in cardiology.

  16. Developments in boron magnetic resonance imaging (MRI)

    Energy Technology Data Exchange (ETDEWEB)

    Schweizer, M.

    1995-11-01

    This report summarizes progress during the past year on maturing Boron-11 magnetic resonance imaging (MRI) methodology for noninvasive determination of BNCT agents (BSH) spatially in time. Three major areas are excerpted: (1) Boron-11 MRI of BSH distributions in a canine intracranial tumor model and the first human glioblastoma patient, (2) whole body Boron-11 MRI of BSH pharmacokinetics in a rat flank tumor model, and (3) penetration of gadolinium salts through the BBB as a function of tumor growth in the canine brain.

  17. Fetal magnetic resonance imaging and human genetics

    Energy Technology Data Exchange (ETDEWEB)

    Hengstschlaeger, Markus [Medical Genetics, Obstetrics and Gynecology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)]. E-mail: markus.hengstschlaeger@meduniwien.ac.at

    2006-02-15

    The use of fetal magnetic resonance imaging (MRI), in addition to prenatal genetic testing and sonography, has the potential to improve prenatal diagnosis of genetic disorders. MRI plays an important role in the evaluation of fetal abnormalities and malformations. Fetal MRI often enables a differential diagnosis, a determination of the extent of the disorder, the prognosis, and an improvement in therapeutic management. For counseling of parents, as well as to basically understand how genetic aberrations affect fetal development, it is of great importance to correlate different genotypes with fetal MRI data.

  18. Magnetic resonance imaging findings in Kimura's disease

    International Nuclear Information System (INIS)

    Although early diagnosis of Kimura's disease, a rare chronic inflammatory disorder most commonly presenting with asymmetric swelling in the head and neck region, is helpful in avoiding unnecessary diagnostic tests and starting prompt treatment, only a few reports emphasized radiological findings in detail. Magnetic resonance imaging findings showing the infiltrative nature of the disease and diffuse loss of fat tissue even in nonpalpable normally appearing regions of the head and neck in a young man with Kimura's disease are presented in this report. (orig.)

  19. Magnetic resonance imaging of cervical myelopathy

    Energy Technology Data Exchange (ETDEWEB)

    Chosa, Hirofumi; Yamano, Kouichirou; Ihara, Fumitoshi; Ueda, Yoshiaki; Maekawa, Masayuki; Tokuhisa, Ginichirou; Kuwano, Tadashi; Kamo, Yoshi; Nomura, Shigeharu (Kyushu Rosai Hospital, Fukuoka (Japan))

    1990-03-01

    Forty-three patients operated for cervical myelopathy were examined with a 1.5 T magnetic resonance imaging. Cord compression was demonstrated directly on the sagittal image in cases of cervical disc herniation, cervical spondylosis and O.P. L.L. Herniated disc material was seen positive on axial image. But factors of cord compression in cases of cervical spondylosis and O.P. L.L. were not clearly confirmed, so additional examinations such as myelogram, tomogram and CT was needed. (author).

  20. Nuclear Magnetic Resonance in Liquids and Solids

    International Nuclear Information System (INIS)

    The paper outlines the basic principles of nuclear magnetic resonance, trying wherever possible to compare and contrast the method with that of slow neutron scattering as a technique for studying the properties of condensed phases and especially of molecular and atomic motions. It is emphasized that this is not a review of nmr for an expert audience but has a pedagogical aim. It is hoped to give persons with a main interest in neutron scattering some appreciation of the scope and limitations of the nmr method. This is illustrated by recent results on one substance which covers many but by no means all of the important points. (author)

  1. Structural magnetic resonance imaging in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Deblaere, Karel [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium); Ghent University Hospital, MR Department - 1K12, Ghent (Belgium); Achten, Eric [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium)

    2008-01-15

    Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance of adequate imaging in patients with focal epilepsy is highlighted. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics depicted. Imaging focus will be on the diagnosis of hippocampal sclerosis and malformations of cortical development, two major causes of medically intractable focal epilepsy. (orig.)

  2. Structural magnetic resonance imaging in epilepsy

    International Nuclear Information System (INIS)

    Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance of adequate imaging in patients with focal epilepsy is highlighted. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics depicted. Imaging focus will be on the diagnosis of hippocampal sclerosis and malformations of cortical development, two major causes of medically intractable focal epilepsy. (orig.)

  3. Magnetic Resonance of Pelvic and Gastrointestinal Emergencies.

    Science.gov (United States)

    Wongwaisayawan, Sirote; Kaewlai, Rathachai; Dattwyler, Matthew; Abujudeh, Hani H; Singh, Ajay K

    2016-05-01

    Magnetic resonance (MR) imaging is gaining increased acceptance in the emergency setting despite the continued dominance of computed tomography. MR has the advantages of more precise tissue characterization, superior soft tissue contrast, and a lack of ionizing radiation. Traditional barriers to emergent MR are being overcome by streamlined imaging protocols and newer rapid-acquisition sequences. As the utilization of MR imaging in the emergency department increases, a strong working knowledge of the MR appearance of the most commonly encountered abdominopelvic pathologies is essential. In this article, MR imaging protocols and findings of acute pelvic, scrotal, and gastrointestinal pathologies are discussed. PMID:27150327

  4. Magnetic resonance spectroscopy studies in migraine

    Energy Technology Data Exchange (ETDEWEB)

    Montagna, P.; Cortelli, P.; Barbiroli, B. (Inst. of Medical Pathology, Univ. of Bologna (Italy))

    1994-06-01

    The authors describe the method of [sup 31]phosphorus magnetic resonance spectroscopy and review the results when it is applied to the study of brain and muscle energy metabolism in migraine subjects. Brain energy metabolism appears to be abnormal in all major subtypes of migraine when measured both during and between attacks. Impaired energy metabolism is also documented in skeletal muscle. It is suggested that migraine is associated with a generalized disorder of mitochondrial oxidative phosphorylation and that this may constitute a threshold for the triggering of migraine attacks. 47 refs., 10 figs., 3 tabs.

  5. Magnetic resonance imaging in rheumatology. An overview.

    Science.gov (United States)

    Nissenbaum, M A; Adamis, M K

    1994-05-01

    Magnetic resonance (MR) imaging has revolutionized the assessment of pathology involving the musculoskeletal system. The soft tissue contrast, superb resolution, multiplanar acquisition potential, and the ability to monitor physiologic processes combine the best features of other imaging modalities. The sensitivity and specificity of MR imaging for a wide range of disease processes matches or supersedes conventional radiology, nuclear medicine, and clinical examination. This article provides a brief overview of the use of MR imaging for some of the more common clinical situations confronting the rheumatologist.

  6. Magnetic resonance imaging of acoustic neuroma

    Energy Technology Data Exchange (ETDEWEB)

    Kashihara, Kengo; Murata, Hideaki; Ito, Haruhide; Onishi, Hiroaki; Kadoya, Masumi; Suzuki, Masayuki.

    1989-03-01

    Thirteen patients with acoustic neuroma were studied on a 1.5T superconductive magnetic resonance (MR) imager. Acoustic neuromas appeared as lower signal intensity than the surrounding brain stem on T1 weighted image (W.I.), and as higher signal intensity on T2 W.I.. Axial and coronal sections of T1 W.I. were very useful in observing the tumor in the auditory canal and in investigating the anatomical relations of the tumor and the surrounding structures. MR imaging is very excellent examination to make early diagnosis of the acoustic neuroma and preoperative anatomical evaluation.

  7. Magnetic resonance-guided prostate interventions.

    Science.gov (United States)

    Haker, Steven J; Mulkern, Robert V; Roebuck, Joseph R; Barnes, Agnieska Szot; Dimaio, Simon; Hata, Nobuhiko; Tempany, Clare M C

    2005-10-01

    We review our experience using an open 0.5-T magnetic resonance (MR) interventional unit to guide procedures in the prostate. This system allows access to the patient and real-time MR imaging simultaneously and has made it possible to perform prostate biopsy and brachytherapy under MR guidance. We review MR imaging of the prostate and its use in targeted therapy, and describe our use of image processing methods such as image registration to further facilitate precise targeting. We describe current developments with a robot assist system being developed to aid radioactive seed placement. PMID:16924169

  8. MRCP. Magnetic resonance cholangiopancreatography; MRCP. Magnetresonanzcholangiopankreatografie

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [Wisconsin-Madison Univ., Madison, WI (United States). Dept. of Radiology; Lauenstein, Thomas [Evangelisches Krankenhaus Duesseldorf (Germany). Radiologie

    2016-06-15

    Magnetic resonance cholangiopancreatography (MRCP) is a special MR technique to display and analyze the biliary tract and pancreatic ducts. MRCP sequences are equivalent to endoscopic retrograde cholangiopancreatography (ERCP) for diagnostic purposes due to technical developments of the classical T2 weighted MRCP sequences and the availability of contrast enhanced T1 weighted sequences. Therefore, MRCP plays a fundamental role in the diagnoses of hepatobliary and pancreatic diseases, which are presented in this review article as are technical details of sequence acquisitions and the underlying anatomy.

  9. In vivo nuclear magnetic resonance imaging

    Science.gov (United States)

    Leblanc, A.

    1986-01-01

    During the past year the Woodlands Baylor Magnetic Resonance Imaging (MRI) facility became fully operational. A detailed description of this facility is given. One significant instrument addition this year was the 100 MHz, 40cm bore superconducting imaging spectrometer. This instrument gives researchers the capability to acquire high energy phosphate spectra. This will be used to investigate ATP, phosphocreatinine and inorganic phosphate changes in normal and atrophied muscle before, during and after exercise. An exercise device for use within the bore of the imaging magnet is under design/construction. The results of a study of T sub 1 and T sub 2 changes in atrophied muscle in animals and human subjects are given. The imaging and analysis of the lower leg of 15 research subjects before and after 5 weeks of complete bedrest was completed. A compilation of these results are attached.

  10. Contrast Agent in Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Vu-Quang, Hieu

    2015-01-01

    for chemotherapy. The nanoparticles were 150 nm in size with spherical shape, which contained PFOB in the inner core and Dox and ICG in the polymeric shell. More importantly, they could target folate receptor expressing cancer cells, which provide positive in vitro and in vivo NIR and 19F MRI results. In project......Nanoparticles have been employed as contrast agent in magnetic resonance imaging (MRI) in order to improve sensitivity and accuracy in diagnosis. In addition, these contrast agents are potentially combined with other therapeutic compounds or near infrared bio-imaging (NIR) fluorophores to obtain...... theranostic or dual imaging purposes, respectively. There were two main types of MRI contrast agent that were synthesized during this PhD project including fluorine containing nanoparticles and magnetic nanoparticles. In regard of fluorine containing nanoparticles, there were two types contrast agent...

  11. Enhancement of magnetic resonance imaging with metasurfaces

    CERN Document Server

    Slobozhanyuk, A P; Raaijmakers, A J E; Berg, C A T van den; Kozachenko, A V; Dubrovina, I A; Melchakova, I V; Kivshar, Yu S; Belov, P A

    2015-01-01

    Magnetic resonance imaging (MRI) is the cornerstone technique for diagnostic medicine, biology, and neuroscience. This imaging method is highly innovative, noninvasive and its impact continues to grow. It can be used for measuring changes in the brain after enhanced neural activity, detecting early cancerous cells in tissue, as well as for imaging nanoscale biological structures, and controlling fluid dynamics, and it can be beneficial for cardiovascular imaging. The MRI performance is characterized by a signal-to-noise ratio, however the spatial resolution and image contrast depend strongly on the scanner design. Here, we reveal how to exploit effectively the unique properties of metasurfaces for the substantial improvement of MRI efficiency. We employ a metasurface created by an array of wires placed inside the MRI scanner under an object, and demonstrate a giant enhancement of the magnetic field by means of subwavelength near-field manipulation with the metasurface, thus strongly increasing the scanner sen...

  12. Magnetic levitation of metamaterial bodies enhanced with magnetostatic surface resonances

    CERN Document Server

    Urzhumov, Yaroslav; Bingham, Chris; Padilla, Willie; Smith, David R

    2011-01-01

    We propose that macroscopic objects built from negative-permeability metamaterials may experience resonantly enhanced magnetic force in low-frequency magnetic fields. Resonant enhancement of the time-averaged force originates from magnetostatic surface resonances (MSR) which are analogous to the electrostatic resonances of negative-permittivity particles, well known as surface plasmon resonances in optics. We generalize the classical problem of MSR of a homogeneous object to include anisotropic metamaterials, and consider the most extreme case of anisotropy where the permeability is negative in one direction but positive in the others. It is shown that deeply subwavelength objects made of such indefinite (hyperbolic) media exhibit a pronounced magnetic dipole resonance that couples strongly to uniform or weakly inhomogeneous magnetic field and provides strong enhancement of the magnetic force, enabling applications such as enhanced magnetic levitation.

  13. Magnetic resonance imaging of the central nervous system

    Energy Technology Data Exchange (ETDEWEB)

    Brant-Zawadzki, M.; Norman, D.

    1987-01-01

    This book presents the papers on technological advancement and diagnostic uses g magnetic resonance imaging. A comparative evaluation with computerized tomography is presented. Topics covered are imaging principles g magnetic resonance;instrumentation of magnetic resonance (MR);pathophysiology;quality and limitations g images;NMR imaging of brain and spinal cord;MR spectroscopy and its applications;neuroanatomy;Congenital malformations of brain and MR imaging;planning g MR imaging of spine and head and neck imaging.

  14. Clinical application of functional magnetic resonance imaging

    CERN Document Server

    Alwatban, A Z W

    2002-01-01

    The work described in this thesis was carried out at the Magnetic Resonance Centre of the University of Nottingham during the time from May 1998 to April 2001, and is the work of the except where indicated by reference. The main source of signal changes in functional magnetic resonance imaging (fMRJ) is the fluctuation of paramagnetic deoxyhaemoglobin in the venous blood during different states of functional performance. For the work of this thesis, fMRI studies were carried out using a 3 T MR system with an echo planar imaging (EPI) pulse sequence. Hearing research utilising fMRI has been previously reported in normal subjects. Hearing fMRI is normally performed by stimulating the auditory cortex via an acoustic task presentation such as music, tone, etc. However, performing the same research on deaf subjects requires special equipment to be designed to allow direct stimulation of the auditory nerve. In this thesis, a new method of direct electrical stimulation of the auditory nerve is described that uses a ...

  15. Magnetic Resonance Microscopy of the Lung

    Science.gov (United States)

    Johnson, G. Allan

    1999-11-01

    The lung presents both challenges and opportunities for study by magnetic resonance imaging (MRI). The technical challenges arise from respiratory and cardiac motion, limited signal from the tissues, and unique physical structure of the lung. These challenges are heightened in magnetic resonance microscopy (MRM) where the spatial resolution may be up to a million times higher than that of conventional MRI. The development of successful techniques for MRM of the lung present enormous opportunities for basic studies of lung structure and function, toxicology, environmental stress, and drug discovery by permitting investigators to study this most essential organ nondestructively in the live animal. Over the last 15 years, scientists at the Duke Center for In Vivo Microscopy have developed techniques for MRM in the live animal through an interdisciplinary program of biology, physics, chemistry, electrical engineering, and computer science. This talk will focus on the development of specialized radiofrequency coils for lung imaging, projection encoding methods to limit susceptibility losses, specialized support structures to control and monitor physiologic motion, and the most recent development of hyperpolarized gas imaging with ^3He and ^129Xe.

  16. Magnetic Resonance Imaging Evaluation of Cardiac Masses

    Energy Technology Data Exchange (ETDEWEB)

    Braggion-Santos, Maria Fernanda, E-mail: ferbraggion@yahoo.com.br [Divisão de Cardiologia do Departamento de Clínica Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Hospital Universitário - Universidade de Heidelberg, Heidelberg (Germany); Koenigkam-Santos, Marcel [Centro de Ciências das Imagens e Física Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Hospital Universitário - Universidade de Heidelberg, Heidelberg (Germany); Teixeira, Sara Reis [Centro de Ciências das Imagens e Física Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Volpe, Gustavo Jardim [Divisão de Cardiologia do Departamento de Clínica Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Divisão de Cardiologia - Universidade Johns Hopkins, Baltimore (United States); Trad, Henrique Simão [Centro de Ciências das Imagens e Física Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Schmidt, André [Divisão de Cardiologia do Departamento de Clínica Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-09-15

    Cardiac tumors are extremely rare; however, when there is clinical suspicion, proper diagnostic evaluation is necessary to plan the most appropriate treatment. In this context, cardiovascular magnetic resonance imaging (CMRI) plays an important role, allowing a comprehensive characterization of such lesions. To review cases referred to a CMRI Department for investigation of cardiac and paracardiac masses. To describe the positive case series with a brief review of the literature for each type of lesion and the role of cardiovascular magnetic resonance imaging in evaluation. Between August 2008 and December 2011, all cases referred for CMRI with suspicion of tumor involving the heart were reviewed. Cases with positive histopathological diagnosis, clinical evolution or therapeutic response compatible with the clinical suspicion and imaging findings were selected. Among the 13 cases included in our study, eight (62%) had histopathological confirmation. We describe five benign tumors (myxomas, rhabdomyoma and fibromas), five malignancies (sarcoma, lymphoma, Richter syndrome involving the heart and metastatic disease) and three non-neoplastic lesions (pericardial cyst, intracardiac thrombus and infectious vegetation). CMRI plays an important role in the evaluation of cardiac masses of non-neoplastic and neoplastic origin, contributing to a more accurate diagnosis in a noninvasive manner and assisting in treatment planning, allowing safe clinical follow-up with good reproducibility.

  17. Magnetic resonance spectroscopy: clinical application in neuroradiology

    International Nuclear Information System (INIS)

    Full text: Magnetic Resonance Spectroscopy (MRS) provides a non-invasive method of studying metabolism in vivo. Magnetic resonance spectroscopy (MRS) defines neuro chemistry on a regional basis by acquiring a radiofrequency signal with chemical shift from one or many voxels or volumes previously selected on MRI. The tissue's chemical environment determines the frequency of a metabolite peak in an MRS spectrum. Candidates for MRS include: 1H, 31P, 13C, 23Na, 7Li, 19F, 14N, 15N, 17O, 39K The most commonly studied nuclei are 1H and 31P. This lecture is focused on Proton (1H) Spectroscopy. Proton MRS can be added on to conventional MR imaging protocols. It can be used to serially monitor biochemical changes in tumors, stroke, epilepsy, metabolic disorders, infections, and neurodegenerative diseases.The MR spectra do not come labeled with diagnoses. They require interpretation and should always be correlated with the MR images before making a final diagnosis. As a general rule, the single voxel, short TE technique is used to make the initial diagnosis, because the signal-to-noise is high and all metabolites are represented. Multi-voxel, long TE techniques are used to further characterize different regions of a mass and to assess brain parenchyma around or adjacent to the mass. Multi-voxel, long TE techniques are also used to assess response to therapy and to search for tumor recurrence. Each metabolite appears at a specific ppm, and each one reflects specific cellular and biochemical processes

  18. Magnetic resonance imaging findings in adnexial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Trindade, Ronald Meira Castro; Quadros, Marianne Siquara de [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Instituto de Ensino e Pesquisa], e-mail: rtrindade@einstein.br; Baroni, Ronaldo Hueb; Rosemberg, Michelle; Racy, Marcelo de Castro Jorge; Tachibana, Adriano [Hospital Albert Einstein, Sao Paulo, SP (Brazil); Funari, Marcelo Buarque de Gusmao [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Imaging Service

    2010-01-15

    Adnexial torsion is an unusual event, but a major cause of abdominal pain in women. It is often associated with ovarian tumor or cyst, but can occur in normal ovaries, especially in children. The twisting of adnexial structures may involve the ovary or tube, but frequently affects both. In most cases, it is unilateral, with slight predilection for the right size. In imaging findings, increased ovarian volume and adnexial masses are observed, with reduced or absent vascularisation. In cases of undiagnosed or untreated complete twist, hemorrhagic necrosis may occur leading to complications; in that, peritonitis is the most frequent. Early diagnosis helps preventing irreversible damage with conservative treatment, thereby saving the ovary. Limitations in performing physical examination, possible inconclusive results in ultrasound and exposure to radiation in computed tomography makes magnetic resonance imaging a valuable tool in emergency assessment of gynecological diseases. The objective of this study was to report two confirmed cases of adnexial twist, emphasizing the contribution of magnetic resonance imaging in the diagnosis of this condition. (author)

  19. General review of magnetic resonance elastography.

    Science.gov (United States)

    Low, Gavin; Kruse, Scott A; Lomas, David J

    2016-01-28

    Magnetic resonance elastography (MRE) is an innovative imaging technique for the non-invasive quantification of the biomechanical properties of soft tissues via the direct visualization of propagating shear waves in vivo using a modified phase-contrast magnetic resonance imaging (MRI) sequence. Fundamentally, MRE employs the same physical property that physicians utilize when performing manual palpation - that healthy and diseased tissues can be differentiated on the basis of widely differing mechanical stiffness. By performing "virtual palpation", MRE is able to provide information that is beyond the capabilities of conventional morphologic imaging modalities. In an era of increasing adoption of multi-parametric imaging approaches for solving complex problems, MRE can be seamlessly incorporated into a standard MRI examination to provide a rapid, reliable and comprehensive imaging evaluation at a single patient appointment. Originally described by the Mayo Clinic in 1995, the technique represents the most accurate non-invasive method for the detection and staging of liver fibrosis and is currently performed in more than 100 centers worldwide. In this general review, the mechanical properties of soft tissues, principles of MRE, clinical applications of MRE in the liver and beyond, and limitations and future directions of this discipline -are discussed. Selected diagrams and images are provided for illustration. PMID:26834944

  20. Magnetic resonance imaging of the bone marrow

    Energy Technology Data Exchange (ETDEWEB)

    Baur-Melnyk, Andrea (ed.) [Klinikum der Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2013-08-01

    The first book devoted to MRI of the bone marrow. Describes the MRI appearances of normal bone marrows and the full range of bone marrow disorders. Discusses the role of advanced MRI techniques and contrast enhancement. On account of its unrivalled imaging capabilities and sensitivity, magnetic resonance imaging (MRI) is considered the modality of choice for the investigation of physiologic and pathologic processes affecting the bone marrow. This book describes the MRI appearances of both the normal bone marrow, including variants, and the full range of bone marrow disorders. Detailed discussion is devoted to malignancies, including multiple myeloma, lymphoma, chronic myeloproliferative disorders, leukemia, and bone metastases. Among the other conditions covered are benign and malignant compression fractures, osteonecrosis, hemolytic anemia, Gaucher's disease, bone marrow edema syndrome, trauma, and infective and non-infective inflammatory disease. Further chapters address the role of MRI in assessing treatment response, the use of contrast media, and advanced MRI techniques. Magnetic Resonance Imaging of the Bone Marrow represents an ideal reference for both novice and experienced practitioners.

  1. Magnetic resonance imaging of congenital cardiac abnormalities

    International Nuclear Information System (INIS)

    Magnetic resonance imaging will not replace echocardiography as the simplest and most definitive method of establishing a noninvasive diagnosis in young patients with congenital cardiac malformations, nor will it replace radionuclide angiography for relatively noninvasive detection and quantitation of cardiac shunts. Magnetic resonance imaging is a complementary noninvasive imaging procedure that can answer some questions left in doubt by echocardiography (mainly extracardiac artery and vein assessments) or radionuclide angiography and used as a preferred follow-up imaging method in certain clinical circumstances. In addition, MRI can be a first-line modality for cardiovascular imaging in older patients in whom adequate echo windows are not available. Angiocardiography remains necessary to provide vital physiological data, i.e., chamber pressures, shunt volumes, oxygen saturations, and pulmonary vascular resistance; however, MRI could negate some follow-up catheterizations in appropriate clinical circumstances. High-resolution proton MRI tomography should ultimately permit the accurate evaluation of ventricular volumes, myocardial mass, and the assessment of regional wall motion and ejection fractions. Paramagnetic substances such as manganese ion may ultimately provide a basis for myocardial perfusion imaging. The potential for MRI evaluation of tissue characterization, noninvasive blood-flow measurements, and myocardial metabolism assessment in intriguing and awaits clinical evaluation

  2. Resonances and dipole moments in dielectric, magnetic, and magnetodielectric cylinders

    DEFF Research Database (Denmark)

    Dirksen, A.; Arslanagic, Samel; Breinbjerg, Olav

    2011-01-01

    An eigenfunction solution to the problem of plane wave scattering by dielectric, magnetic, and magnetodielectric cylinders is used for a systematic investigation of their resonances. An overview of the resonances with electric and magnetic dipole moments, needed in, e.g., the synthesis of metamat......An eigenfunction solution to the problem of plane wave scattering by dielectric, magnetic, and magnetodielectric cylinders is used for a systematic investigation of their resonances. An overview of the resonances with electric and magnetic dipole moments, needed in, e.g., the synthesis...

  3. Ultra-high-field magnetic resonance: Why and when?

    OpenAIRE

    Moser, Ewald

    2010-01-01

    This paper briefly summarizes the development of magnetic resonance imaging and spectroscopy in medicine. Aspects of magnetic resonancephysics and -technology relevant at ultra-high magnetic fields as well as current limitations are highlighted. Based on the first promising studies, potential clinical applications at 7 Tesla are suggested. Other aims are to stimulate awareness of the potential of ultra-high field magnetic resonance and to stimulate active participation in much needed basic or...

  4. Purely electric and magnetic dipole resonances in metamaterial dielectric resonators through perturbation theory inspired geometries

    CERN Document Server

    Campione, Salvatore; Warne, Larry K; Sinclair, Michael B

    2014-01-01

    In this paper we describe a methodology for tailoring the design of metamaterial dielectric resonators, which represent a promising path toward low-loss metamaterials at optical frequencies. We first describe a procedure to decompose the far field scattered by subwavelength resonators in terms of multipolar field components, providing explicit expressions for the multipolar far fields. We apply this formulation to confirm that an isolated high-permittivity cube resonator possesses frequency separated electric and magnetic dipole resonances, as well as a magnetic quadrupole resonance in close proximity to the electric dipole resonance. We then introduce multiple dielectric gaps to the resonator geometry in a manner suggested by perturbation theory, and demonstrate the ability to overlap the electric and magnetic dipole resonances, thereby enabling directional scattering by satisfying the first Kerker condition. We further demonstrate the ability to push the quadrupole resonance away from the degenerate dipole ...

  5. Spatial localization in nuclear magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Keevil, Stephen F [Department of Medical Physics, Guy' s and St Thomas' NHS Foundation Trust, Guy' s Hospital, London, SE1 9RT (United Kingdom); Division of Imaging Sciences, King' s College London, Guy' s Campus, London, SE1 9RT (United Kingdom)

    2006-08-21

    The ability to select a discrete region within the body for signal acquisition is a fundamental requirement of in vivo NMR spectroscopy. Ideally, it should be possible to tailor the selected volume to coincide exactly with the lesion or tissue of interest, without loss of signal from within this volume or contamination with extraneous signals. Many techniques have been developed over the past 25 years employing a combination of RF coil properties, static magnetic field gradients and pulse sequence design in an attempt to meet these goals. This review presents a comprehensive survey of these techniques, their various advantages and disadvantages, and implications for clinical applications. Particular emphasis is placed on the reliability of the techniques in terms of signal loss, contamination and the effect of nuclear relaxation and J-coupling. The survey includes techniques based on RF coil and pulse design alone, those using static magnetic field gradients, and magnetic resonance spectroscopic imaging. Although there is an emphasis on techniques currently in widespread use (PRESS, STEAM, ISIS and MRSI), the review also includes earlier techniques, in order to provide historical context, and techniques that are promising for future use in clinical and biomedical applications. (topical review)

  6. Magnetic resonance tracking of fluorescent nanodiamond fabrication

    International Nuclear Information System (INIS)

    Magnetic resonance techniques (electron paramagnetic resonance (EPR) and nuclear magnetic resonance (NMR)) are used for tracking the multi-stage process of the fabrication of fluorescent nanodiamonds (NDs) produced by high-energy electron irradiation, annealing, and subsequent nano-milling. Pristine commercial high pressure and high temperature microdiamonds (MDs) with mean size 150 μm contain ∼5  ×  1018 spins/g of singlet (S = 1/2) substitutional nitrogen defects P1, as well as sp3 C–C dangling bonds in the crystalline lattice. The half-field X-band EPR clearly shows (by the appearance of the intense ‘forbidden’ g = 4.26 line) that high-energy electron irradiation and annealing of MDs induce a large amount (∼5  ×  1017 spins/g) of triplet (S = 1) magnetic centers, which are identified as negatively charged nitrogen vacancy defects (NV−). This is supported by EPR observations of the ‘allowed’ transitions between Zeeman sublevels of the triplet state. After progressive milling of the fluorescent MDs down to an ultrasubmicron scale (≤100 nm), the relative abundance of EPR active NV− defects in the resulting fluorescent NDs (FND) substantially decreases and, vice versa, the content of C-inherited singlet defects correlatively increases. In the fraction of the finest FNDs (mean particle size <20 nm), which are contained in the dried supernatant of ultracentrifuged aqueous dispersion of FNDs, the NV− content is found to be reduced by one order of magnitude whereas the singlet defects content increases up to ∼2  ×  1019 spins/g. In addition, another triplet-type defect, which is characterized by the g = 4.00 ‘forbidden’ line, appears. On reduction of the particle size below the 20 nm limit, the ‘allowed’ EPR lines become practically unobservable, whereas the ‘forbidden’ lines remain as a reliable fingerprint of the presence of NV− centers in small ND systems. The same size reduction causes the

  7. [Septic arthritis of thoracic facet joint].

    Science.gov (United States)

    Ben Abdelghani, K; Gérard-Dran, D; Combe, B

    2009-08-01

    Septic arthritis of the facet joint is a rare condition. We report a case of septic arthritis of both a thoracic facet joint and a wrist. Clinical manifestations were consistent with a spondylodiscitis. Magnetic resonance imaging of the spine demonstrated infection of facet joints of T1 and T2. A surgical biopsy of the wrist isolated a type B streptococcus. The same organism was found in urine culture. The patient had an uneventful recovery on antibiotics.

  8. 类风湿性关节炎手腕关节MRI弥散加权成像与滑膜病理相关性分析%Magnetic resonance diffusion-weighted imaging of hand and wrist joints in rheumatoid arthritis:correlated with synovial pathology

    Institute of Scientific and Technical Information of China (English)

    陈悦熙; 张芳; 沈君

    2012-01-01

    目的 分析类风湿性关节炎手腕部MRI及弥散加权成像(DWI)表现,并与临床滑膜病理指标作相关性分析,探讨MRI对评估双手、腕类风湿关节炎的严重程度及临床活动性的价值.方法 对15例确诊RA患者行双手MRI检查,并与临床症状和实验室检查进行相关性分析,测量DWI上滑膜ADC值,与滑膜穿刺活检的病理学指标进行相关性分析.结果 MRI滑膜炎评分、骨侵蚀评分、骨髓水肿评分及总分均与C反应蛋白(CRP)、可视化量表(VAS)有相关性;DWI的ADC值与滑膜病理评分具有负相关.结论 MRI能清楚显示RA手腕部小关节的病理改变.MRI可对RA的滑膜炎、骨侵蚀、骨髓水肿进行半定量化分级评分,MRI评分与临床指标有一定相关性,对双手、腕类风湿关节炎的活动性评估具有重要价值.DWI结合ADC值测量,可更加直接地反映病变关节的活动程度.%Objective To analyze magnetic resonance imaging and diffusion-weighted imaging of hand and wrist joints in rheumatoid arthritis ( RA) patients to investigate the value of MR imaging in the evaluation the disease severity and activity by correlating the MR findings with clinical and synovium histological features. Methods Fifteen patients with RA were enrolled. All patients underwent MR examination on both wrists and the 2th to 5th metacarpophalangeals( MCP) . The clinical and laboratory parameters of each patient were record and correlated with MR parameters. On DWI, the ADC of involved joints were measured and correlated with the histological parameters that were observed on the histological examination from synovial biopsy. Results Synovitis score of MRI, bone erosion score, bone marrow edema score and the total score were correlated with CRP and VAS. ADC value measured on DWI was negatively correlated with histological synovitis score. Conclusions MRI can clearly display the pathological changes of the hand and wrist joints in RA patients. MRI can be used

  9. Basic concepts from magnetic resonance imaging

    International Nuclear Information System (INIS)

    The use of magnetic resonance imaging (MRI) has grown exponentially, due in part to excellent anatomic and pathologic detail provided by the modality, as recent technological advances that have led to more rapid acquisition times. Radiology residents in different parts of the world now receive training in MR images from their first year of residence, included the pulse sequences training spin-echo, gradient-echo, inversion-recovery, echo-planar image and MR angiographic sequences, commonly used in medical imaging. However, to optimize the use of this type of study, it has been necessary to understand the basic concepts of physics, included the concepts of recovery T1, degradation T2* and T2, repetition time, echo time, and the effects of chemical shift. Additionally, it has been important to understand the contrast weighting for better representation of specific tissues and thus perform an appropriate differential diagnosis of various pathological processes. (author)

  10. Valuation for magnetic resonance of neuro tuberculosis

    International Nuclear Information System (INIS)

    The increased incidence of neuro tuberculosis (NTB), due to the world epidemic of resistant strains and AIDS, has made of magnetic resonance (MR) imaging the study of choice for the early detection of lesions that lead the clinicians to an effective treatment. We present our experience with six cases of NTB, with meningoencephalic (4 cases), spinal, (1 case) and epidural (1 case) involvement. We identified basal arachnoiditis that was also seen on CT. Two cases demonstrated non-classifying tuberculomas, the spinal lesion consisted of casseifying tuberculoma that responded to treatment and disappeared on a follow up MR study. Epidural involvement consisted of Pott's disease with displacement and edema of the spinal cord. The differential diagnosis of these lesions includes mycoses, cysticercosis, sarcoidosis and leptomeningeal metastases

  11. Functional Magnetic Resonance Imaging in Consumer Research

    DEFF Research Database (Denmark)

    Reimann, Martin; Schilke, Oliver; Weber, Bernd;

    2011-01-01

    of prior fMRI research related to consumer behavior and highlights the features that make fMRI an attractive method for consumer and marketing research. The authors discuss advantages and limitations and illustrate the proposed procedures with an applied study, which investigates loss aversion when buying......Although the field of psychology is undergoing an immense shift toward the use of functional magnetic resonance imaging (fMRI), the application of this methodology to consumer research is relatively new. To assist consumer researchers in understanding fMRI, this paper elaborates on the findings...... and selling a common product. Results reveal a significantly stronger activation in the amygdala while consumers estimate selling prices versus buying prices, suggesting that loss aversion is associated with the processing of negative emotion. © 2011 Wiley Periodicals, Inc....

  12. Pulsed nuclear-electronic magnetic resonance

    CERN Document Server

    Morley, Gavin W; Mohammady, M Hamed; Aeppli, Gabriel; Kay, Christopher W M; Jeschke, Gunnar; Monteiro, Tania S

    2011-01-01

    Pulsed magnetic resonance is a wide-reaching technology allowing the quantum state of electronic and nuclear spins to be controlled on the timescale of nanoseconds and microseconds respectively. The time required to flip either dilute electronic or nuclear spins is orders of magnitude shorter than their decoherence times, leading to several schemes for quantum information processing with spin qubits. We investigate instead the novel regime where the eigenstates approximate 50:50 superpositions of the electronic and nuclear spin states forming "nuclear-electronic" qubits. Here we demonstrate quantum control of these states, using bismuth-doped silicon, in just 32 ns: orders of magnitude shorter than previous experiments where pure nuclear states were used. The coherence times of our states are over four orders of magnitude longer, being 1 ms or more at 8 K, and are limited by the naturally-occurring 29Si nuclear spin impurities. There is quantitative agreement between our experiments and no-free-parameter anal...

  13. Magnetic resonance imaging in patients with panhypopituitarism

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Mucelli, R.S. [Ist. di Radiologia, Univ. di Trieste, Ospedale di Cattinara (Italy); Frezza, F. [Ist. di Radiologia, Univ. di Trieste, Ospedale di Cattinara (Italy); Magnaldi, S. [Ist. di Radiologia, Univ. di Trieste, Ospedale di Cattinara (Italy); Proto, G. [Servizio di Endocrinologia, Ospedale Civile di Udine (Italy)

    1992-02-01

    Primary panhypopituitarism consists of functional deficiency of the anterior pituitary lobe, which appears during infancy or adolescence. The magnetic resonance findings in 10 patients with a history of primary hypopituitarism are presented. The findings include: reduced pituitary size in all cases; partially (8 cases) or totally (2 cases) empty sella; thin (4 cases), partially visible (3 cases) or absent (2 cases) pituitary stalk; absence of the posterior lobe in 9 cases; bright spot corresponding to an ectopic posterior lobe in 8 cases. These findings are similar to those already reported in pituitary dwarfism and may help understanding of the pathogenesis of the disease, which seems to be related to a pituitary stalk lesion. (orig.)

  14. Magnetic resonance imaging after exposure to microgravity

    Science.gov (United States)

    Leblanc, Adrian

    1993-01-01

    A number of physiological changes were demonstrated in bone, muscle, and blood from exposure of humans and animals to microgravity. Determining mechanisms and the development of effective countermeasures for long-duration space missions is an important NASA goal. Historically, NASA has had to rely on tape measures, x-ray, and metabolic balance studies with collection of excreta and blood specimens to obtain this information. The development of magnetic resonance imaging (MRI) offers the possibility of greatly extending these early studies in ways not previously possible; MRI is also non-invasive and safe; i.e., no radiation exposure. MRI provides both superb anatomical images for volume measurements of individual structures and quantification of chemical/physical changes induced in the examined tissues. This investigation will apply MRI technology to measure muscle, intervertebral disc, and bone marrow changes resulting from exposure to microgravity.

  15. Cardiovascular magnetic resonance in carotid atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Chen Huijun

    2009-12-01

    Full Text Available Abstract Atherosclerosis is a chronic, progressive, inflammatory disease affecting many vascular beds. Disease progression leads to acute cardiovascular events such as myocardial infarction, stroke and death. The diseased carotid alone is responsible for one third of the 700,000 new or recurrent strokes occurring yearly in the United States. Imaging plays an important role in the management of atherosclerosis, and cardiovascular magnetic resonance (CMR of the carotid vessel wall is one promising modality in the evaluation of patients with carotid atherosclerotic disease. Advances in carotid vessel wall CMR allow comprehensive assessment of morphology inside the wall, contributing substantial disease-specific information beyond luminal stenosis. Although carotid vessel wall CMR has not been widely used to screen for carotid atherosclerotic disease, many trials support its potential for this indication. This review summarizes the current state of knowledge regarding carotid vessel wall CMR and its potential clinical application for management of carotid atherosclerotic disease.

  16. Magnetic resonance imaging of brain death

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D.H.; Nathanson, J.A.; Fox, A.J.; Pelz, D.M.; Lownie, S.P.

    1995-06-01

    In order to demonstrate the magnetic resonance imaging (MRI) appearance of the brain in patients with clinical brain death, high-field MRI was performed on 5 patients using conventional T1-weighted and T2-weighted imaging. The study showed MRI exhibited similar features for all of the patients, features which were not found in MRI of comatose patients who were not clinically brain dead. It was stated that up to now the most important limitation in MRI of patients with suspected brain death has been the extreme difficulty of moving them out of the intensive care setting. If this problem can be overcome, and it appears possible with with the advent of MRI-compatible ventilators and noninvasive monitoring, MRI could become an excellent alternative for confirming clinical diagnosis of brain death for such patients. 15 refs., 3 figs.

  17. Magnetic Earth Ionosphere Resonant Frequencies (MEIRF) project

    Science.gov (United States)

    Spaniol, Craig

    1993-01-01

    The West Virginia State College Community College Division NASA Magnetic Earth Ionosphere Resonant Frequencies (MEIRF) study is described. During this contract period, the two most significant and professionally rewarding events were the presentation of the research activity at the Sir Isaac Newton Conference in St. Petersburg, Russia, and the second Day of Discovery Conference, focusing on economic recovery in West Virginia. An active antenna concept utilizing a signal feedback principle similar to regenerative receivers used in early radio was studied. The device has potential for ELF research and other commercial applications for improved signal reception. Finally, work continues to progress on the development of a prototype monitoring station. Signal monitoring, data display, and data storage are major areas of activity. In addition, we plan to continue our dissemination of research activity through presentations at seminars and other universities.

  18. Magnetic resonance imaging of the heart.

    Science.gov (United States)

    Tscholakoff, D; Higgins, C B

    1985-01-01

    Magnetic resonance imaging (MRI) is a completely noninvasive technique for the evaluation of the cardiovascular system. With a multi-section technique and the spin echo pulse sequence the entire heart can be examined within six to ten minutes. All our cardiac MR studies were performed with electrocardiographic (ECG) gating, to obtain adequate resolution of the cardiac structures. With this technique, patients and animals with a variety of cardiac abnormalities were studied. The examined pathologic conditions included acute and chronic myocardial infarctions and their complications, hypertrophic and congestive cardiomyopathies, congenital heart diseases and pericardial diseases. MRI offers an enormous potential for cardiovascular diagnosis, even beyond the demonstration of pathoanatomy, because of the capability for direct tissue characterization and blood flow measurements.

  19. Magnetic resonance imaging of optic nerve

    Directory of Open Access Journals (Sweden)

    Foram Gala

    2015-01-01

    Full Text Available Optic nerves are the second pair of cranial nerves and are unique as they represent an extension of the central nervous system. Apart from clinical and ophthalmoscopic evaluation, imaging, especially magnetic resonance imaging (MRI, plays an important role in the complete evaluation of optic nerve and the entire visual pathway. In this pictorial essay, the authors describe segmental anatomy of the optic nerve and review the imaging findings of various conditions affecting the optic nerves. MRI allows excellent depiction of the intricate anatomy of optic nerves due to its excellent soft tissue contrast without exposure to ionizing radiation, better delineation of the entire visual pathway, and accurate evaluation of associated intracranial pathologies.

  20. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...... is based on determination of the left-ventricular endocardial and epicardial borders. Since manual border detection is laborious, automated segmentation is highly desirable as a fast, objective and reproducible alternative. Automated segmentation will thus enhance comparability between and within cardiac...... studies and increase accuracy by allowing acquisition of thinner MRI-slices. This abstract demonstrates that statistical models of shape and appearance, namely the deformable models: Active Appearance Models, can successfully segment cardiac MRIs....

  1. Magnetic Resonance Imaging in occult spinal dysraphism

    International Nuclear Information System (INIS)

    A prospective study was carried out in 100 cases of suspected occult spinal dysraphic anomalies with Magnetic Resonance Imaging (MRI) in order to determine its diagnostic efficacy as the initial imaging modality. MR imaging provided accurate preoperative information in 91 out of 92 cases (98.9%). Some of the unusual and interesting findings in the series were: presence of intrinsic cord abnormality in 19 out of 21 cases (90.4%) with a normal plain radiography, 4 cases of diastematomyelia with a dermoid in the dorsal and lumbar region associated with syringohydromyelia, intradural fibrous/glial bands, syringo-hydromyelia/myelomalacia of the conus with tethered cord syndrome having a normally paced conus, and myelocystocele. It is concluded that MRI is an excellent primary diagnostic tool, together with a plain radiography, for complete preoperative evaluation of mid-line spinal anomalies. 14 refs., 3 tabs., 7 figs

  2. Safety of magnetic resonance contrast media.

    Science.gov (United States)

    Runge, V M

    2001-08-01

    Intravenous contrast media, specifically the gadolinium chelates, are well accepted for use in the clinical practice of magnetic resonance imaging. The gadolinium chelates are considered to be very safe and lack (in intravenous use) the nephrotoxicity found with iodinated contrast media. Minor adverse reactions, including nausea and hives, occur in a low percentage of cases. The four agents currently available in the United States cannot be differentiated on the basis of these adverse reactions. Severe anaphylactoid reactions are also known to occur with all agents, although these are uncommon. This review discusses the safety issues involved with intravenous administration of the gadolinium chelates and off-label use. The latter is common in clinical practice and permits broader application of these agents. PMID:11687717

  3. Quantum information processing and nuclear magnetic resonance

    CERN Document Server

    Cummins, H K

    2001-01-01

    as spectrometer pulse sequence programs. Quantum computers are information processing devices which operate by and exploit the laws of quantum mechanics, potentially allowing them to solve problems which are intractable using classical computers. This dissertation considers the practical issues involved in one of the more successful implementations to date, nuclear magnetic resonance (NMR). Techniques for dealing with systematic errors are presented, and a quantum protocol is implemented. Chapter 1 is a brief introduction to quantum computation. The physical basis of its efficiency and issues involved in its implementation are discussed. NMR quantum information processing is reviewed in more detail in Chapter 2. Chapter 3 considers some of the errors that may be introduced in the process of implementing an algorithm, and high-level ways of reducing the impact of these errors by using composite rotations. Novel general expressions for stabilising composite rotations are presented in Chapter 4 and a new class o...

  4. Magnetic resonance imaging of intervertebral disc degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Hiroshi; Noguchi, Masao (Kitakyushu City Yahata Hospital, Fukuoka (Japan)); Kira, Hideaki; Fujiki, Hiroshi; Shimokawa, Isao; Hinoue, Kaichi

    1993-02-01

    The aim of this study was to correlate the degree of lumbar intervertebral disc degeneration with findings of magnetic resonance imaging (MRI). Seventeen autopsied (from 7 patients) and 21 surgical (from 20 patients) intervertebral discs were used as specimens for histopathological examination. In addition, 21 intervertebral discs were examined on T2-weighted images. Histopathological findings from both autopsied and surgical specimens were well correlated with MRI findings. In particular, T2-weighted images reflected increased collagen fibers and rupture within the fibrous ring accurately. However, when severely degenerated intervertebral discs and hernia protruding the posterior longitudinal ligament existed, histological findings were not concordant well with T2-weighted images. Morphological appearances of autopsy specimens, divided into four on T2-weighted images, were well consistent with histological degeneration. This morphological classification, as shown on T2-weighted images, could also be used in the evaluation of intervertebral disc degeneration. (N.K.).

  5. Monitoring angiogenesis using magnetic resonance methods

    DEFF Research Database (Denmark)

    Holm, David Alberg

    2008-01-01

    -angiogenic treatment is presented in the first manuscript. In the second and third manuscript, two separate methods of quantifying perfusion, blood volume and vessel permeability are presented. The methods are used to show that drug delivery to a xenografted tumor is plausible and to show possible vascular maturation......When a tumor reaches a certain size it can no longer rely on passive perfusion for nutrition. The tumor therefore emits signaling molecules which stimulating surrounding vessels to divide and grow towards the tumor, a process known as angiogenesis. Very little angiogenesis is present in healthy...... and the involved signaling molecules. Subsequently, a short review of contrast agents and perfusion measurements is given. Finally, methods for monitoring angiogenesis using magnetic resonance imaging are reviewed. A method for monitoring early stages of angiogenesis as well as the effect of anti...

  6. Magnetic resonance imaging of pancreatitis: an update.

    Science.gov (United States)

    Manikkavasakar, Sriluxayini; AlObaidy, Mamdoh; Busireddy, Kiran K; Ramalho, Miguel; Nilmini, Viragi; Alagiyawanna, Madhavi; Semelka, Richard C

    2014-10-28

    Magnetic resonance (MR) imaging plays an important role in the diagnosis and staging of acute and chronic pancreatitis and may represent the best imaging technique in the setting of pancreatitis due to its unmatched soft tissue contrast resolution as well as non-ionizing nature and higher safety profile of intravascular contrast media, making it particularly valuable in radiosensitive populations such as pregnant patients, and patients with recurrent pancreatitis requiring multiple follow-up examinations. Additional advantages include the ability to detect early forms of chronic pancreatitis and to better differentiate adenocarcinoma from focal chronic pancreatitis. This review addresses new trends in clinical pancreatic MR imaging emphasizing its role in imaging all types of acute and chronic pancreatitis, pancreatitis complications and other important differential diagnoses that mimic pancreatitis. PMID:25356038

  7. Chest magnetic resonance imaging: a protocol suggestion

    Directory of Open Access Journals (Sweden)

    Bruno Hochhegger

    2015-12-01

    Full Text Available Abstract In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation.

  8. Cardiovascular magnetic resonance in hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Shiozaki, Afonso Akio; Parga, Jose Rodrigues; Arteaga, Edmundo; Rochitte, Carlos Eduardo [Sao Paulo Univ. (USP), SP (Brazil). Instituto do Coracao. Setor de Tomografia Computarizada e Ressonancia Magnetica Cardiovascular]. E-mail: rochitte@incor.usp.br; Kim, Raymond J. [Duke Cardiovascular Magnetic Resonance Center, Durham, NC (United States); Tassi, Eduardo Marinho [Diagnosticos da America S.A., Rio de Janeiro, RJ (Brazil). Sector of Cardiovascular Magnetic Resonance and Computed Tomography

    2007-03-15

    Hypertrophic cardiomyopathy (HCM) is the most frequent genetic cardiac disease that causes sudden death in young people, with an incidence of 1:500 adults. The routinely used criteria for worst prognosis have limited sensitivity and specificity. Thus, the estimated risk of evolving to dilated cardiomyopathy or sudden death is somewhat inaccurate, leading to management uncertainty of HCM patients. Therefore, an accurate noninvasive method for the diagnosis of HCM with prognostic value is of great importance. In the last years, Cardiovascular Magnetic Resonance (CMR) emerged not only as a diagnostic tool, but also as a study with prognostic values, by characterizing myocardial fibrosis with great accuracy in HCM patients. Additionally, CMR identifies the types of hypertrophy, analyses the ventricular function, estimates the intraventricular gradient and allows the determination of differential diagnosis. Moreover, CMR can uniquely access myocardial fibrosis in HCM. (author)

  9. Two-dimensional nuclear magnetic resonance petrophysics.

    Science.gov (United States)

    Sun, Boqin; Dunn, Keh-Jim

    2005-02-01

    Two-dimensional nuclear magnetic resonance (2D NMR) opens a wide area for exploration in petrophysics and has significant impact to petroleum logging technology. When there are multiple fluids with different diffusion coefficients saturated in a porous medium, this information can be extracted and clearly delineated from CPMG measurements of such a system either using regular pulsing sequences or modified two window sequences. The 2D NMR plot with independent variables of T2 relaxation time and diffusion coefficient allows clear separation of oil and water signals in the rocks. This 2D concept can be extended to general studies of fluid-saturated porous media involving other combinations of two or more independent variables, such as chemical shift and T1/T2 relaxation time (reflecting pore size), proton population and diffusion contrast, etc. PMID:15833623

  10. Magnetic resonance imaging of cerebrotendinous xanthomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Tai, K.S.; Brockwell, J.; Chan, F.L.; Janus, E.D.; Lam, K.S.L.

    1995-02-01

    Cerebrotendinous xanthomatosis (CTX) is a rare genetic disorder in which cholestanol and cholesterol accumulate in the nervous system and other tissues. It has an autosomal recessive mode of inheritance. Most patients are of low intelligence with poor school performance. Specific clinical manifestations include xanthomas of the tendons. Furthermore, patients develop cataracts and a slowly progressive cerebellar ataxia. There is slight mental deterioration. Death usually occurs in the sixth or seventh decade and is often due to unrelated causes. Plasma cholesterol levels are normal or only moderately elevated. The pattern of serum lipids is normal, and only serum cholestanol is significantly increased. Radiological features of the disease are infrequently described in the literature. We report a case of CTX in which magnetic resonance imaging (MRI) was used to image the brain, lumbar spine and the tendinous xanthomas of the lower limbs. 15 refs., 5 figs.

  11. Computed tomography and magnetic resonance findings in lipoid pneumonia.

    OpenAIRE

    Bréchot, J M; Buy, J N; Laaban, J P; Rochemaure, J

    1991-01-01

    A case of exogenous lipoid pneumonia was documented by computed tomography and magnetic resonance imaging. Although strongly suggesting the presence of fat on T1 weighted images, magnetic resonance does not produce images specific for this condition. Computed tomography is the best imaging modality for its diagnosis.

  12. Magnetic resonance imaging of the saccular otolithic mass.

    OpenAIRE

    Sbarbati, A; Leclercq, F; Antonakis, K; Osculati, F.

    1992-01-01

    The frog's inner ear was studied in vivo by high spatial resolution magnetic resonance imaging at 7 Tesla. The vestibule, the internal acoustic meatus, and the auditory tube have been identified. The large otolithic mass contained in the vestibule showed a virtual absence of magnetic resonance signal probably due to its composition of closely packed otoconia.

  13. Parametric resonance in vircator with applied magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Grigoryev, V.P.; Koval, T.V. [Inst. of Nuclear Physics, Tomsk (Russian Federation)

    1995-11-01

    The investigation of electromagnetic oscillations excitation in the vircator with an external magnetic field is carried out. The conditions of producing of cyclotron wave parametric resonance with virtual cathode oscillations harmonics have been obtained where the radiation power resonance character depends on the magnetic field value.

  14. Magnetic Resonance Studies of Energy Storage Materials

    Science.gov (United States)

    Vazquez Reina, Rafael

    In today's society there is high demand to have access to energy for portable devices in different forms. Capacitors with high performance in small package to achieve high charge/discharge rates, and batteries with their ability to store electricity and make energy mobile are part of this demand. The types of internal dielectric material strongly affect the characteristics of a capacitor, and its applications. In a battery, the choice of the electrolyte plays an important role in the Solid Electrolyte Interphase (SEI) formation, and the cathode material for high output voltage. Electron Paramagnetic Resonance (EPR) and Nuclear Magnetic Resonance (NMR) spectroscopy are research techniques that exploit the magnetic properties of the electron and certain atomic nuclei to determine physical and chemical properties of the atoms or molecules in which they are contained. Both EPR and NMR spectroscopy technique can yield meaningful structural and dynamic information. Three different projects are discussed in this dissertation. First, High energy density capacitors where EPR measurements described herein provide an insight into structural and chemical differences in the dielectric material of a capacitor. Next, as the second project, Electrolyte solutions where an oxygen-17 NMR study has been employed to assess the degree of preferential solvation of Li+ ions in binary mixtures of EC (ethylene carbonate) and DMC (dimethyl carbonate) containing LiPF6 (lithium hexafluo-rophosphate) which may be ultimately related to the SEI formation mechanism. The third project was to study Bismuth fluoride as cathode material for rechargeable batteries. The objective was to study 19F and 7Li MAS NMR of some nanocomposite cathode materials as a conversion reaction occurring during lithiation and delithation of the BiF3/C nanocomposite.

  15. Rotating-frame gradient fields for magnetic resonance imaging and nuclear magnetic resonance in low fields

    Science.gov (United States)

    Bouchard, Louis-Serge; Pines, Alexander; Demas, Vasiliki

    2014-01-21

    A system and method for Fourier encoding a nuclear magnetic resonance (NMR) signal is disclosed. A static magnetic field B.sub.0 is provided along a first direction. An NMR signal from the sample is Fourier encoded by applying a rotating-frame gradient field B.sub.G superimposed on the B.sub.0, where the B.sub.G comprises a vector component rotating in a plane perpendicular to the first direction at an angular frequency .omega.in a laboratory frame. The Fourier-encoded NMR signal is detected.

  16. Compact electrically detected magnetic resonance setup

    International Nuclear Information System (INIS)

    Electrically detected magnetic resonance (EDMR) is a commonly used technique for the study of spin-dependent transport processes in semiconductor materials and electro-optical devices. Here, we present the design and implementation of a compact setup to measure EDMR, which is based on a commercially available benchtop electron paramagnetic resonance (EPR) spectrometer. The electrical detection part uses mostly off-the-shelf electrical components and is thus highly customizable. We present a characterization and calibration procedure for the instrument that allowed us to quantitatively reproduce results obtained on a silicon-based reference sample with a “large-scale” state-of-the-art instrument. This shows that EDMR can be used in novel contexts relevant for semiconductor device fabrication like clean room environments and even glove boxes. As an application example, we present data on a class of environment-sensitive objects new to EDMR, semiconducting organic microcrystals, and discuss similarities and differences to data obtained for thin-film devices of the same molecule

  17. Effects of magnetic fields on dissolution of arthritis causing crystals

    Science.gov (United States)

    Takeuchi, Y.; Iwasaka, M.

    2015-05-01

    The number of gout patients has rapidly increased because of excess alcohol and salt intake. The agent responsible for gout is the monosodium urate (MSU) crystal. MSU crystals are found in blood and consist of uric acid and sodium. As a substitute for drug dosing or excessive water intake, physical stimulation by magnetic fields represents a new medical treatment for gout. In this study, we investigated the effects of a magnetic field on the dissolution of a MSU crystal suspension. The white MSU crystal suspension was dissolved in an alkaline solution. We measured the light transmission of the MSU crystal suspension by a transmitted light measuring system. The magnetic field was generated by a horizontal electromagnet (maximum field strength was 500 mT). The MSU crystal suspension that dissolved during the application of a magnetic field of 500 mT clearly had a higher dissolution rate when compared with the control sample. We postulate that the alkali solution promoted penetration upon diamagnetic rotation and this magnetic field orienting is because of the pronounced diamagnetic susceptibility anisotropy of the MSU crystal. The results indicate that magnetic fields represent an effective gout treatment approach.

  18. Magnetic resonance imaging in clinically-definite multiple sclerosis

    International Nuclear Information System (INIS)

    Forty-two patients with clinically-definite multiple sclerosis were examined by magnetic resonance imaging using a 1.5-T instrument. Magnetic resonance imaging detected an abnormality in 90% of patients. In four patients, no lesions were demonstrated. The number, size and site of the lesions by magnetic resonance imaging were compared with the patients' clinical status and other variables. The Kurtzke disability status scale score increased in patients with corpus callosum atrophy, brainstem and basal ganglia lesions, and correlated with the total number of lesions. No correlation was shown between the findings of magnetic resonance imaging and disease duration, age, sex or pattern-reversal visual-evoked potentials. The variety of magnetic resonance images that could be obtained in patients with clinically-definite multiple sclerosis is highlighted. 24 refs., 8 figs., 1 tab

  19. Magnetic resonance spectroscopy as a diagnostic modality for carcinoma thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Nikhil [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India)], E-mail: nikhil_ms26@yahoo.co.in; Kakar, Arun K. [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India); Chowdhury, Veena [Department of Radiodiagnosis, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India); Gulati, Praveen [MR Centre, A-23 Green Park, New Delhi (India); Shankar, L. Ravi [Department of Radioiodine Uptake and Imaging, Institute of Nucler Medicine and Allied Sciences (INMAS), Timarpur, New Delhi (India); Vindal, Anubhav [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India)

    2007-12-15

    Aim: The aim of this study was to observe the findings of magnetic resonance spectroscopy of solitary thyroid nodules and its correlation with histopathology. Materials and methods: In this study, magnetic resonance spectroscopy was carried out on 26 patients having solitary thyroid nodules. Magnetic resonance spectroscopy (MRS) was performed on a 1.5 T super conductive system with gradient strength of 33 mTs. Fine needle aspiration cytology was done after MRS. All 26 patients underwent surgery either because of cytopathologically proven malignancy or because of cosmetic reasons. Findings of magnetic resonance spectroscopy were compared with histopathology of thyroid specimens. Results and conclusion: It was seen that presence or absence of choline peak correlates very well with presence or absence of malignant foci with in the nodule (sensitivity = 100%; specificity = 88.88%). These results indicate that magnetic resonance spectroscopy may prove to be an useful diagnostic modality for carcinoma thyroid.

  20. Travelling Wave Magnetic Resonance Imaging at 3 Tesla

    OpenAIRE

    Vazquez, F; Martin, R.; Marrufo, O.; Rodriguez, A. O.

    2013-01-01

    Waveguides have been successfully used to generate magnetic resonance images at 7 T with whole-body systems. The bore limits the magnetic resonance signal transmitted because its specific cut-off frequency is greater than the majority of resonant frequencies. This restriction can be overcome by using a parallel-plate waveguide whose cut-off frequency is zero for the transversal electric modes and it can propagate any frequency. To investigate the potential benefits for whole-body imaging at 3...

  1. Electric and magnetic dipole couplings in split ring resonator metamaterials

    Institute of Scientific and Technical Information of China (English)

    Fan Jing; Sun Guang-Yong; and Zhu Wei-Ren

    2011-01-01

    In this paper,the electric and the magnetic dipole couplings between the outer and the inner rings of a single split ring resonator (SRR) are investigated.We numerically demonstrate that the magnetic resonance frequency can be substantially modified by changing the couplings of the electric and magnetic dipoles,and give a theoretical expression of the magnetic resonance frequency.The results in this work are expected to be conducive to a deeper understanding of the SRR and other similar metamaterials,and provide new guidance for complex metamaterials design with a tailored electromagnetic response.

  2. Characterization of human breast disease using phosphorus magnetic resonance spectroscopy and proton magnetic resonance imaging

    International Nuclear Information System (INIS)

    This thesis provides the fundamental characterization and differentiation of breast tissues using in vivo and ex vivo MR techniques in the hope that these techniques and experimental findings will be used on a larger scale and in a predictive manner in order to improve the specificity of diagnosis and treatment of breast cancer. In this dissertation, clinical studies were performed using proton magnetic resonance imaging and phosphorus magnetic resonance spectro-scopy (31P MRS) to characterize and differentiate malignant breast tumors, benign breast tumors and normal breast tissues in vivo. These studies were carried out following the methodical characterization of chemical extracts of malignant breast tumor, benign breast tumor and normal breast parenchymal surgical tissue specimens using high resolution 31P MRS. Alterations in breast tissue metabolism, as a result of pathological processes, were postulated to be responsible for measurable differences between malignant breast tumors, benign breast tumors and normal breast tissues using magnetic resonance techniques. (author). 365 refs.; 37 figs.; 25 tabs

  3. Experiments in Nuclear Magnetic Resonance Microscopy

    Science.gov (United States)

    Lee, Yong; Lu, Wei; Choi, J.-H.; Chia, H. J.; Mirsaidov, U. M.; Guchhait, S.; Cambou, A. D.; Cardenas, R.; Park, K.; Markert, J. T.

    2006-03-01

    We report our group's effort in the construction of an 8-T, ^3 He cryostat based nuclear magnetic resonance force microscope (NMRFM). The probe has two independent 3-D of piezoelectric x-y-z positioners for precise positioning of a fiber optic interferometer and a sample/gradient-producing magnet with respect to a micro-cantilever. The piezoelectric positioners have a very uniform controllable step size with virtually no backlash. A novel RF tuning circuit board design is implemented which allows us to simply swap out one RF component board with another for experiments involving different nuclear species. We successfully fabricated and are characterizing 50μm x50μm x0.2μm double torsional oscillators. We have also been characterizing ultrasoft cantilevers whose spring constant is on the order of 10-4 N/m. We also report NMRFM data for ammonium dihydrogen phosphate(ADP) at room temperature using our 1.2-T system. Observed features include the correct shift of the NMR peak with carrier frequency, increases in signal amplitude with both RF field strength and frequency modulation amplitude, and signal oscillation (spin nutation) as a function of tipping RF pulse length. Experiments in progress on NH4MgF3 (at 1.2 T) and MgB2 (at 8.1 T) will also be briefly reviewed. Robert A. Welch Foundation grant No.F-1191 and the National Science Foundation grant No. DMR-0210383.

  4. Italian registry of cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Francone, Marco [Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome (Italy); Di Cesare, Ernesto, E-mail: ernesto.dicesare@cc.univaq.it [Dipartimento di Scienze Cliniche Applicate e Biotecnologie, Università di L’Aquila (Italy); Cademartiri, Filippo [Cardio-Vascular Imaging Unit, Giovanni XXIII Hospital, Monastier di Treviso, TV (Italy); Erasmus Medical Center University, Rotterdam (Netherlands); Pontone, Gianluca [IRCCS Centro Cardiologico Monzino (Italy); Lovato, Luigi [Policlinico S. Orsola Bologna (Italy); Matta, Gildo [Azienda ospedaliera G Brotzu Cagliari (Italy); Secchi, Francesco [IRCCS Policlinico San Donato, Radiology Unit, Milan (Italy); Maffei, Erica [Cardio-Vascular Imaging Unit, Giovanni XXIII Hospital, Monastier di Treviso, TV (Italy); Erasmus Medical Center University, Rotterdam (Netherlands); Pradella, Silvia [Azienda Ospedaliera Universitaria Careggi (Italy); Carbone, Iacopo [Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome (Italy); Marano, Riccardo [Policlinico Gemelli, Università Cattolica Roma (Italy); Bacigalupo, Lorenzo [Ospedale Galliera, Genova (Italy); Chiodi, Elisabetta [Ospedale S. Anna Ferrara (Italy); Donato, Rocco [Azienda Ospedaliera Universitaria G. Martino, Me (Italy); Sbarbati, Stefano [Ospedale Madre Giuseppina Vannini, Roma (Italy); De Cobelli, Francesco [IRCCS S. Raffaele, Università Vita Salute, Milano (Italy); Di Renzi, Paolo [Fate Bene Fratelli Isola tiberina, Roma (Italy); Ligabue, Guido; Mancini, Andrea [Azienda Ospedaliera-Universitaria Policlinico di Modena (Italy); Palmieri, Francesco [Diparimento di Diagnostica per immagini e radiologia interventistica, Ospedale S. Maria delle Grazie, Pozzuoli, Napoli (Italy); and others

    2014-01-15

    Objectives: Forty sites were involved in this multicenter and multivendor registry, which sought to evaluate indications, spectrum of protocols, impact on clinical decision making and safety profile of cardiac magnetic resonance (CMR). Materials and methods: Data were prospectively collected on a 6-month period and included 3376 patients (47.2 ± 19 years; range 1–92 years). Recruited centers were asked to complete a preliminary general report followed by a single form/patient. Referral physicians were not required to exhibit any specific certificate of competency in CMR imaging. Results: Exams were performed with 1.5 T scanners in 96% of cases followed by 3 T (3%) and 1 T (1%) magnets and contrast was administered in 84% of cases. The majority of cases were performed for the workup of inflammatory heart disease/cardiomyopathies representing overall 55.7% of exams followed by the assessment of myocardial viability and acute infarction (respectively 6.9% and 5.9% of patients). In 49% of cases the final diagnosis provided was considered relevant and with impact on patient's clinical/therapeutic management. Safety evaluation revealed 30 (0.88%) clinical events, most of which due to patient's preexisting conditions. Radiological reporting was recorded in 73% of exams. Conclusions: CMR is performed in a large number of centers in Italy with relevant impact on clinical decision making and high safety profile.

  5. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.)

  6. Clinical application of functional magnetic resonance imaging

    International Nuclear Information System (INIS)

    The work described in this thesis was carried out at the Magnetic Resonance Centre of the University of Nottingham during the time from May 1998 to April 2001, and is the work of the author except where indicated by reference. The main source of signal changes in functional magnetic resonance imaging (fMRJ) is the fluctuation of paramagnetic deoxyhaemoglobin in the venous blood during different states of functional performance. For the work of this thesis, fMRI studies were carried out using a 3 T MR system with an echo planar imaging (EPI) pulse sequence. Hearing research utilising fMRI has been previously reported in normal subjects. Hearing fMRI is normally performed by stimulating the auditory cortex via an acoustic task presentation such as music, tone, etc. However, performing the same research on deaf subjects requires special equipment to be designed to allow direct stimulation of the auditory nerve. In this thesis, a new method of direct electrical stimulation of the auditory nerve is described that uses a transtympanic electrode implanted onto the surface of the cochlea. This approach would however, result in electromotive forces (EMFs) being induced by the time varying magnetic field, which would lead to current flow and heating, as well as deflection of the metallic electrode within the static magnetic field, and image distortion due to the magnetic susceptibility difference. A gold-plated tungsten electrode with a zero magnetic susceptibility was developed to avoid image distortion. Used with carbon leads and a carbon reference pad, it enabled safe, distortion-free fMRI studies of deaf subjects. The study revealed activation of the primary auditory cortex. This fMRI procedure can be used to demonstrate whether the auditory pathway is fully intact, and may provide a useful method for pre-operative assessment of candidates for cochlear implantation. Glucose is the energy source on which the function of the human brain is entirely dependent. Failure to

  7. Clinical application of functional magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Alwatban, Adnan Z.W

    2002-07-01

    The work described in this thesis was carried out at the Magnetic Resonance Centre of the University of Nottingham during the time from May 1998 to April 2001, and is the work of the author except where indicated by reference. The main source of signal changes in functional magnetic resonance imaging (fMRJ) is the fluctuation of paramagnetic deoxyhaemoglobin in the venous blood during different states of functional performance. For the work of this thesis, fMRI studies were carried out using a 3 T MR system with an echo planar imaging (EPI) pulse sequence. Hearing research utilising fMRI has been previously reported in normal subjects. Hearing fMRI is normally performed by stimulating the auditory cortex via an acoustic task presentation such as music, tone, etc. However, performing the same research on deaf subjects requires special equipment to be designed to allow direct stimulation of the auditory nerve. In this thesis, a new method of direct electrical stimulation of the auditory nerve is described that uses a transtympanic electrode implanted onto the surface of the cochlea. This approach would however, result in electromotive forces (EMFs) being induced by the time varying magnetic field, which would lead to current flow and heating, as well as deflection of the metallic electrode within the static magnetic field, and image distortion due to the magnetic susceptibility difference. A gold-plated tungsten electrode with a zero magnetic susceptibility was developed to avoid image distortion. Used with carbon leads and a carbon reference pad, it enabled safe, distortion-free fMRI studies of deaf subjects. The study revealed activation of the primary auditory cortex. This fMRI procedure can be used to demonstrate whether the auditory pathway is fully intact, and may provide a useful method for pre-operative assessment of candidates for cochlear implantation. Glucose is the energy source on which the function of the human brain is entirely dependent. Failure to

  8. Controlling interactions between highly-magnetic atoms with Feshbach resonances

    CERN Document Server

    Kotochigova, Svetlana

    2014-01-01

    This paper reviews current experimental and theoretical progress in the study of dipolar quantum gases of ground and meta-stable atoms with a large magnetic moment. We emphasize the anisotropic nature of Feshbach resonances due to coupling to fast-rotating resonant molecular states in ultracold s-wave collisions between magnetic atoms in external magnetic fields. The dramatic differences in the distribution of resonances of magnetic $^7$S$_3$ chromium and magnetic lanthanide atoms with a submerged 4f shell and non-zero electron angular momentum is analyzed. We focus on Dysprosium and Erbium as important experimental advances have been recently made to cool and create quantum-degenerate gases for these atoms. Finally, we describe progress in locating resonances in collisions of meta-stable magnetic atoms in electronic P states with ground-state atoms, where an interplay between collisional anisotropies and spin-orbit coupling exists.

  9. Resonant modes of vortex structures in soft-magnetic nanodiscs

    International Nuclear Information System (INIS)

    We present micromagnetic finite-element simulations on the dynamic response of a soft-magnetic disc exposed to an oscillatory field applied in the disc plane. The disc is magnetized in a vortex state. At lower frequencies (about 200 MHz in our example) we find a motion of the vortex core on an elliptical orbit as a resonant mode. At higher frequencies, the out-of-plane component of the magnetization becomes resonant by the excitation of standing magnetostatic waves

  10. Quantifying mixing using magnetic resonance imaging.

    Science.gov (United States)

    Tozzi, Emilio J; McCarthy, Kathryn L; Bacca, Lori A; Hartt, William H; McCarthy, Michael J

    2012-01-25

    Mixing is a unit operation that combines two or more components into a homogeneous mixture. This work involves mixing two viscous liquid streams using an in-line static mixer. The mixer is a split-and-recombine design that employs shear and extensional flow to increase the interfacial contact between the components. A prototype split-and-recombine (SAR) mixer was constructed by aligning a series of thin laser-cut Poly (methyl methacrylate) (PMMA) plates held in place in a PVC pipe. Mixing in this device is illustrated in the photograph in Fig. 1. Red dye was added to a portion of the test fluid and used as the minor component being mixed into the major (undyed) component. At the inlet of the mixer, the injected layer of tracer fluid is split into two layers as it flows through the mixing section. On each subsequent mixing section, the number of horizontal layers is duplicated. Ultimately, the single stream of dye is uniformly dispersed throughout the cross section of the device. Using a non-Newtonian test fluid of 0.2% Carbopol and a doped tracer fluid of similar composition, mixing in the unit is visualized using magnetic resonance imaging (MRI). MRI is a very powerful experimental probe of molecular chemical and physical environment as well as sample structure on the length scales from microns to centimeters. This sensitivity has resulted in broad application of these techniques to characterize physical, chemical and/or biological properties of materials ranging from humans to foods to porous media (1, 2). The equipment and conditions used here are suitable for imaging liquids containing substantial amounts of NMR mobile (1)H such as ordinary water and organic liquids including oils. Traditionally MRI has utilized super conducting magnets which are not suitable for industrial environments and not portable within a laboratory (Fig. 2). Recent advances in magnet technology have permitted the construction of large volume industrially compatible magnets suitable for

  11. Quantifying mixing using magnetic resonance imaging.

    Science.gov (United States)

    Tozzi, Emilio J; McCarthy, Kathryn L; Bacca, Lori A; Hartt, William H; McCarthy, Michael J

    2012-01-01

    Mixing is a unit operation that combines two or more components into a homogeneous mixture. This work involves mixing two viscous liquid streams using an in-line static mixer. The mixer is a split-and-recombine design that employs shear and extensional flow to increase the interfacial contact between the components. A prototype split-and-recombine (SAR) mixer was constructed by aligning a series of thin laser-cut Poly (methyl methacrylate) (PMMA) plates held in place in a PVC pipe. Mixing in this device is illustrated in the photograph in Fig. 1. Red dye was added to a portion of the test fluid and used as the minor component being mixed into the major (undyed) component. At the inlet of the mixer, the injected layer of tracer fluid is split into two layers as it flows through the mixing section. On each subsequent mixing section, the number of horizontal layers is duplicated. Ultimately, the single stream of dye is uniformly dispersed throughout the cross section of the device. Using a non-Newtonian test fluid of 0.2% Carbopol and a doped tracer fluid of similar composition, mixing in the unit is visualized using magnetic resonance imaging (MRI). MRI is a very powerful experimental probe of molecular chemical and physical environment as well as sample structure on the length scales from microns to centimeters. This sensitivity has resulted in broad application of these techniques to characterize physical, chemical and/or biological properties of materials ranging from humans to foods to porous media (1, 2). The equipment and conditions used here are suitable for imaging liquids containing substantial amounts of NMR mobile (1)H such as ordinary water and organic liquids including oils. Traditionally MRI has utilized super conducting magnets which are not suitable for industrial environments and not portable within a laboratory (Fig. 2). Recent advances in magnet technology have permitted the construction of large volume industrially compatible magnets suitable for

  12. Non-resonant magnetic braking on JET and TEXTOR

    DEFF Research Database (Denmark)

    Sun, Y.; Liang, Y.; Shaing, K.C.;

    2012-01-01

    The non-resonant magnetic braking effect induced by a non-axisymmetric magnetic perturbation is investigated on JET and TEXTOR. The collisionality dependence of the torque induced by the n = 1, where n is the toroidal mode number, magnetic perturbation generated by the error field correction coil...

  13. [Rheumatoid arthritis].

    Science.gov (United States)

    Strunk, J; Lange, U; Müller-Ladner, U

    2005-07-29

    The development of novel anti-rheumatic drugs revolutionizes currently therapeutic strategies and diagnostic management of patients with rheumatoid arthritis, facilitating the goal of true remission instead of only symptomatic treatment as in former years. Since early treatment is known to be crucial for the longterm outcome, imaging modalities such as magnetic resonance imaging and high-frequency ultrasonography including Doppler sonography, which allow direct visualization of very early pathologic alterations of synovitis, or even initial destruction, become increasingly important. Besides the established therapy with methotrexate, new drugs such as leflunomide or the use of various combination therapies have been successfully introduced into the therapeutic armamentarium. Especially the introduction of cytokine-antagonists such as TNF-a inhibitors target the aim of remission. In addition, the upcoming therapeutic agents, which influence very effectively the inflammatory and destructive process need also to be integrated into the concert of different therapeutic strategies in the management of patients with rheumatoid arthritis, which includes the mandatory complementary factors such as physiotherapy, ergotherapy and orthopedic surgery.

  14. [Rheumatoid arthritis].

    Science.gov (United States)

    Strunk, J; Lange, U; Müller-Ladner, U

    2005-07-29

    The development of novel anti-rheumatic drugs revolutionizes currently therapeutic strategies and diagnostic management of patients with rheumatoid arthritis, facilitating the goal of true remission instead of only symptomatic treatment as in former years. Since early treatment is known to be crucial for the longterm outcome, imaging modalities such as magnetic resonance imaging and high-frequency ultrasonography including Doppler sonography, which allow direct visualization of very early pathologic alterations of synovitis, or even initial destruction, become increasingly important. Besides the established therapy with methotrexate, new drugs such as leflunomide or the use of various combination therapies have been successfully introduced into the therapeutic armamentarium. Especially the introduction of cytokine-antagonists such as TNF-a inhibitors target the aim of remission. In addition, the upcoming therapeutic agents, which influence very effectively the inflammatory and destructive process need also to be integrated into the concert of different therapeutic strategies in the management of patients with rheumatoid arthritis, which includes the mandatory complementary factors such as physiotherapy, ergotherapy and orthopedic surgery. PMID:16049881

  15. Resonant Mode Reduction in Radiofrequency Volume Coils for Ultrahigh Field Magnetic Resonance Imaging

    OpenAIRE

    Xiaoliang Zhang; Daniel Vigneron; Ye Li; Duan Xu; Yong Pang; Zhentian Xie

    2011-01-01

    In a multimodal volume coil, only one mode can generate homogeneous Radiofrequency (RF) field for Magnetic Resonance Imaging. The existence of other modes may increase the volume coil design difficulties and potentially decreases coil performance. In this study, we introduce common-mode resonator technique to high and ultrahigh field volume coil designs to reduce the resonant mode while maintain the homogeneity of the RF field. To investigate the design method, the common-mode resonator was r...

  16. Advances in cardiac magnetic resonance imaging of congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Driessen, Mieke M.P. [University of Utrecht, University Medical Center Utrecht, Department of Radiology, PO Box 85500, Utrecht (Netherlands); University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); The Interuniversity Cardiology Institute of the Netherlands (ICIN) - Netherlands Heart Institute, PO Box 19258, Utrecht (Netherlands); Breur, Johannes M.P.J. [Wilhelmina Children' s Hospital, University Medical Center Utrecht, Department of Pediatric Cardiology, PO Box 85500, Utrecht (Netherlands); Budde, Ricardo P.J.; Oorschot, Joep W.M. van; Leiner, Tim [University of Utrecht, University Medical Center Utrecht, Department of Radiology, PO Box 85500, Utrecht (Netherlands); Kimmenade, Roland R.J. van; Sieswerda, Gertjan Tj [University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); Meijboom, Folkert J. [University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); Wilhelmina Children' s Hospital, University Medical Center Utrecht, Department of Pediatric Cardiology, PO Box 85500, Utrecht (Netherlands)

    2015-01-01

    Due to advances in cardiac surgery, survival of patients with congenital heart disease has increased considerably during the past decades. Many of these patients require repeated cardiovascular magnetic resonance imaging to assess cardiac anatomy and function. In the past decade, technological advances have enabled faster and more robust cardiovascular magnetic resonance with improved image quality and spatial as well as temporal resolution. This review aims to provide an overview of advances in cardiovascular magnetic resonance hardware and acquisition techniques relevant to both pediatric and adult patients with congenital heart disease and discusses the techniques used to assess function, anatomy, flow and tissue characterization. (orig.)

  17. Science Drivers and Technical Challenges for Advanced Magnetic Resonance

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Karl T.; Pruski, Marek; Washton, Nancy M.; Lipton, Andrew S.

    2013-03-07

    This report recaps the "Science Drivers and Technical Challenges for Advanced Magnetic Resonance" workshop, held in late 2011. This exploratory workshop's goal was to discuss and address challenges for the next generation of magnetic resonance experimentation. During the workshop, participants from throughout the world outlined the science drivers and instrumentation demands for high-field dynamic nuclear polarization (DNP) and associated magnetic resonance techniques, discussed barriers to their advancement, and deliberated the path forward for significant and impactful advances in the field.

  18. Magnetic resonance imaging of a brain abscess

    International Nuclear Information System (INIS)

    Magnetic resonance imaging (MRI) was performed on 13 patients with brain abscesses, and the alternation of MRI findings, as correlated with the progression of brain-abscess formation, was reviewed. In the cerebritis stage, spin-echo images showed a high intensity, and inversion-recovery images, a low intensity, due to inflammation and edema. The spin-echo images were very sensitive in delineating the brain edema; however, it was difficult to distinguish the inflammation from the surrounding edema. In the capsule stage, due to the accumulation of purulent material, the central necrotic area was demonstrated as a low-intensity area, while the capsule of the abscess was revealed as an iso-intensity ring on the inversion-recovery images. The central necrotic area also decreased in intensity on spin-echo images in the later period of this stage. With contrast enhancement (Gd-DTPA), the SR image showed the capsule as a high-intensity ring. MRI was found to be a useful method for estimating the process of the formation of a brain abscess. (author)

  19. Magnetic resonance imaging of a brain abscess

    Energy Technology Data Exchange (ETDEWEB)

    Oikawa, Akihiro; Kagawa, Mizuo; Yatoh, Seiji; Izawa, Masahiro; Ujiie, Hiroshi; Sakaguchi, Jun; Onda, Hideaki; Kitamura, Kohichi

    1988-06-01

    Magnetic resonance imaging (MRI) was performed on 13 patients with brain abscesses, and the alternation of MRI findings, as correlated with the progression of brain-abscess formation, was reviewed. In the cerebritis stage, spin-echo images showed a high intensity, and inversion-recovery images, a low intensity, due to inflammation and edema. The spin-echo images were very sensitive in delineating the brain edema; however, it was difficult to distinguish the inflammation from the surrounding edema. In the capsule stage, due to the accumulation of purulent material, the central necrotic area was demonstrated as a low-intensity area, while the capsule of the abscess was revealed as an iso-intensity ring on the inversion-recovery images. The central necrotic area also decreased in intensity on spin-echo images in the later period of this stage. With contrast enhancement (Gd-DTPA), the SR image showed the capsule as a high-intensity ring. MRI was found to be a useful method for estimating the process of the formation of a brain abscess.

  20. Magnetic resonance imaging of cystic periventricular leukomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Kadoi, Nobuaki; Nomura, Junko; Nowatari, Masahiko; Ohta, Takeo; Kamohara, Takashi; Yashiro, Kimio (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine)

    1990-08-01

    A study was performed to assess the values of magnetic resonance (MR) imaging in evaluation and the follow up of patients with cystic periventricular leukomalacia. Ten patients selected for MR imaging were diagnosed as having periventricular cystic lesions based on US scans. The range of gestational ages was 27 to 32 weeks, and the range of birth weights was 927 to 2,046 g. Twenty MR examinations were carried out using a 0.5 T superconducting system (Resona; Yokogawa). On the first MR examinations, taken by 6 months of age, low signal intensity lesions within the periventricular white matter, moderate ventriculomegaly with irregularity of the ventricular wall and delayed myelination were observed. These were the MR findings observed in the subacute stage of PVL. On the second or the third MR examinations, taken after 12 months of age, increased signal intensity in periventricular white matter on T{sub 2} weighted images decreased volume of periventricular white matter and centrum semiovale and the ventriculomagaly with irregularity of ventricular wall were observed. However, progressions of myelination were proved to be not delayed in comparison with age matched controls. These were thought to be the MR findings of late stage of PVL. As the US findings of PVL have good correlation with pathologic changes revealed at autopsy, MR imaging can depict myelination and detect PVL lesion beyond the neonatal period. These observations demonstrate the value of the MR imaging for the follow up of the patients with PVL beyond the time of fontanel closure. (author).

  1. Magnetic resonance perfusion imaging without contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Martirosian, Petros; Graf, Hansjoerg; Schick, Fritz [University Hospital of Tuebingen, Section on Experimental Radiology, Tuebingen (Germany); Boss, Andreas; Schraml, Christina; Schwenzer, Nina F.; Claussen, Claus D. [University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2010-08-15

    Principles of magnetic resonance imaging techniques providing perfusion-related contrast weighting without administration of contrast media are reported and analysed systematically. Especially common approaches to arterial spin labelling (ASL) perfusion imaging allowing quantitative assessment of specific perfusion rates are described in detail. The potential of ASL for perfusion imaging was tested in several types of tissue. After a systematic comparison of technical aspects of continuous and pulsed ASL techniques the standard kinetic model and tissue properties of influence to quantitative measurements of perfusion are reported. For the applications demonstrated in this paper a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion preparation approach followed by true fast imaging with steady precession (true FISP) data recording was developed and implemented on whole-body scanners operating at 0.2, 1.5 and 3 T for quantitative perfusion measurement in various types of tissue. ASL imaging provides a non-invasive tool for assessment of tissue perfusion rates in vivo. Images recorded from kidney, lung, brain, salivary gland and thyroid gland provide a spatial resolution of a few millimetres and sufficient signal to noise ratio in perfusion maps after 2-5 min of examination time. Newly developed ASL techniques provide especially high image quality and quantitative perfusion maps in tissues with relatively high perfusion rates (as also present in many tumours). Averaging of acquisitions and image subtraction procedures are mandatory, leading to the necessity of synchronization of data recording to breathing in abdominal and thoracic organs. (orig.)

  2. Exploring brain function with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Since its invention in the early 1990s, functional magnetic resonance imaging (fMRI) has rapidly assumed a leading role among the techniques used to localize brain activity. The spatial and temporal resolution provided by state-of-the-art MR technology and its non-invasive character, which allows multiple studies of the same subject, are some of the main advantages of fMRI over the other functional neuroimaging modalities that are based on changes in blood flow and cortical metabolism. This paper describes the basic principles and methodology of fMRI and some aspects of its application to functional activation studies. Attention is focused on the physiology of the blood oxygenation level-dependent (BOLD) contrast mechanism and on the acquisition of functional time-series with echo planar imaging (EPI). We also provide an introduction to the current strategies for the correction of signal artefacts and other image processing techniques. In order to convey an idea of the numerous applications of fMRI, we will review some of the recent results in the fields of cognitive and sensorimotor psychology and physiology

  3. Magnetic Resonance Imaging Features of Neuromyelitis Optica

    Energy Technology Data Exchange (ETDEWEB)

    You, Sun Kyung; Song, Chang June; Park, Woon Ju; Lee, In Ho; Son, Eun Hee [Chungnam National University College of Medicine, Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2013-03-15

    To report the magnetic resonance (MR) imaging features of the spinal cord and brain in patients of neuromyelitis optica (NMO). Between January 2001 and March 2010, the MR images (spinal cord, brain, and orbit) and the clinical and serologic findings of 11 NMO patients were retrospectively reviewed. The contrast-enhancement of the spinal cord was performed (20/23). The presence and pattern of the contrast-enhancement in the spinal cord were classified into 5 types. Acute myelitis was monophasic in 8 patients (8/11, 72.7%); and optic neuritis preceded acute myelitis in most patients. Longitudinally extensive cord lesion (average, 7.3 vertebral segments) was involved. The most common type was the diffuse and subtle enhancement of the spinal cord with a multifocal nodular, linear or segmental intense enhancement (45%). Most of the brain lesions (5/11, 10 lesions) were located in the brain stem, thalamus and callososeptal interphase. Anti-Ro autoantibody was positive in 2 patients, and they showed a high relapse rate of acute myelitis. Anti-NMO IgG was positive in 4 patients (4/7, 66.7%). The imaging findings of acute myelitis in NMO may helpful in making an early diagnosis of NMO which can result in a severe damage to the spinal cord, and to make a differential diagnosis of multiple sclerosis and inflammatory diseases of the spinal cord such as toxocariasis.

  4. Magnetic resonance imaging of primary vaginal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, M.B. [Department of Diagnostic Radiology, Christie Hospital NHS Trust, Withington, Manchester (United Kingdom)]. E-mail: ben.taylor@christie-tr.nwest.nhs.uk; Dugar, N. [Department of Diagnostic Radiology, Christie Hospital NHS Trust, Withington, Manchester (United Kingdom); Davidson, S.E. [Radiation Oncology, Christie Hospital NHS Trust, Withington, Manchester (United Kingdom); Carrington, B.M. [Department of Diagnostic Radiology, Christie Hospital NHS Trust, Withington, Manchester (United Kingdom)

    2007-06-15

    Aims: To describe the magnetic resonance imaging (MRI) features of vaginal carcinoma and to suggest a role for MRI in its management. Materials and methods: Twenty-five patients with primary vaginal carcinoma treated at our institution between 1996 and 2005 were included in the study. The MRI examinations were reviewed and tumour dimensions, signal characteristics and involvement of pelvic structures were documented, as were sites of enlarged lymph nodes and metastases. Details of patient treatment and outcome were obtained from the clinical notes. Results: The median patient age was 54 years (range 31-86 years). Tumour maximum diameter ranged from 1.6-11.3 cm (mean 3.7 cm). Most tumours were of iso-intense signal to muscle on T1-weighted images and hyper-intense to muscle on T2-weighted images. Eighty-eight percent of patients had tumour extending beyond the vagina and 56% of patients had Figo stage III or above tumours. Sixteen patients were treated with radiotherapy (two with chemoradiotherapy), five with surgery and four with supportive care. Ten patients (40%) died of their disease during the study period. The MRI stage of the tumour correlated with survival. Conclusion: MRI identified over 95% of primary vaginal tumours in the present study, enabled radiological staging, which correlated with outcome, and provided information of use in treatment planning.

  5. Magnetic resonance imaging structured reporting in infertility.

    Science.gov (United States)

    Montoliu-Fornas, Guillermina; Martí-Bonmatí, Luis

    2016-06-01

    Our objective was to define and propose a standardized magnetic resonance (MR) imaging structured report in patients with infertility to have clinical completeness on possible diagnosis and severity. Patients should be studied preferable on 3T equipment with a surface coil. Standard MR protocol should include high-resolution fast spin-echo T2-weighted, diffusion-weighted images and gradient-echo T1-weighted fat suppression images. The report should include ovaries (polycystic, endometrioma, tumor), oviduct (hydrosalpinx, hematosalpinx, pyosalpinx, peritubal anomalies), uterus (agenesia, hypoplasia, unicornuate, uterus didelphys, bicornuate, septate uterus), myometrium (leiomyomas, adenomyosis), endometrium (polyps, synechia, atrophy, neoplasia), cervix and vagina (isthmoceles, mucosal-parietal irregularity, stenosis, neoplasia), peritoneum (deep endometriosis), and urinary system-associated abnormalities. To be clinically useful, radiology reports must be structured, use standardized terminology, and convey actionable information. The structured report must comprise complete, comprehensive, and accurate information, allowing radiologists to continuously interact with patients and referring physicians to confirm that the information is used properly to affect the decision making process. PMID:27105717

  6. Cardiovascular magnetic resonance in pericardial diseases

    Directory of Open Access Journals (Sweden)

    Francone Marco

    2009-05-01

    Full Text Available Abstract The pericardium and pericardial diseases in particular have received, in contrast to other topics in the field of cardiology, relatively limited interest. Today, despite improved knowledge of pathophysiology of pericardial diseases and the availability of a wide spectrum of diagnostic tools, the diagnostic challenge remains. Not only the clinical presentation may be atypical, mimicking other cardiac, pulmonary or pleural diseases; in developed countries a shift for instance in the epidemiology of constrictive pericarditis has been noted. Accurate decision making is crucial taking into account the significant morbidity and mortality caused by complicated pericardial diseases, and the potential benefit of therapeutic interventions. Imaging herein has an important role, and cardiovascular magnetic resonance (CMR is definitely one of the most versatile modalities to study the pericardium. It fuses excellent anatomic detail and tissue characterization with accurate evaluation of cardiac function and assessment of the haemodynamic consequences of pericardial constraint on cardiac filling. This review focuses on the current state of knowledge how CMR can be used to study the most common pericardial diseases.

  7. Fetal magnetic resonance imaging and ultrasound.

    Science.gov (United States)

    Wataganara, Tuangsit; Ebrashy, Alaa; Aliyu, Labaran Dayyabu; Moreira de Sa, Renato Augusto; Pooh, Ritsuko; Kurjak, Asim; Sen, Cihat; Adra, Abdallah; Stanojevic, Milan

    2016-07-01

    Magnetic resonance imaging (MRI) has been increasingly adopted in obstetrics practice in the past three decades. MRI aids prenatal ultrasound and improves diagnostic accuracy for selected maternal and fetal conditions. However, it should be considered only when high-quality ultrasound cannot provide certain information that affects the counseling, prenatal intervention, pregnancy course, and delivery plan. Major indications of fetal MRI include, but are not restricted to, morbidly adherent placenta, selected cases of fetal brain anomalies, thoracic lesions (especially in severe congenital diaphragmatic hernia), and soft tissue tumors at head and neck regions of the fetus. For fetal anatomy assessment, a 1.5-Tesla machine with a fast T2-weighted single-shot technique is recommended for image requisition of common fetal abnormalities. Individual judgment needs to be applied when considering usage of a 3-Tesla machine. Gadolinium MRI contrast is not recommended during pregnancy. MRI should be avoided in the first half of pregnancy due to small fetal structures and motion artifacts. Assessment of fetal cerebral cortex can be achieved with MRI in the third trimester. MRI is a viable research tool for noninvasive interrogation of the fetus and the placenta. PMID:27092644

  8. Magnetic resonance imaging of the normal placenta

    Energy Technology Data Exchange (ETDEWEB)

    Blaicher, Wibke [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria)]. E-mail: wibke.blaicher@meduniwien.ac.at; Brugger, Peter C. [Center of Anatomy and Cell Biology, University Hospital of Vienna (Austria); Mittermayer, Christoph [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Schwindt, Jens [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Deutinger, Josef [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Bernaschek, Gerhard [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Prayer, Daniela [Department of Radiology, Division of Neuroradiology, University Hospital of Vienna (Austria)

    2006-02-15

    The goal of this study was to provide a representative description of the normal placenta with contrast medium-free magnetic resonance imaging (MRI) in order to determine a standard of reference. One hundred consecutive singleton pregnancies were investigated by MRI without application of a contrast medium. The mean gestational age (GA) at the time of investigation was 29.5 weeks (range 19-40). Patients with suspected utero-placental insufficiency (UPI) or placental anomalies were excluded. Signal intensities were assessed and correlated with the respective GA. Antenatal MRI without contrast medium was able to depict placental status and morphological changes during gestation. A regular homogeneous structure was found in weeks 19-23. Subsequently, sporadic, slightly marked lobules appeared, which increased in number and markedness with ongoing gestation. Stratification of the lobules was observed after 36 weeks. The ratio of placental and amniotic fluid signal intensities decreased significantly with higher GA and with placental grading. MRI is well suited as an imaging method for the placenta. Our data may be used as a reference in the assessment of the placenta on MRI, and may have further clinical impact with respect to the determination of UPI.

  9. Magnetic resonance tomography of the knee joint

    International Nuclear Information System (INIS)

    To compare the diagnostic performance of magnetic resonance imaging (MRI) in terms of sensitivity and specificity using a field strength of <1.0 T (T) versus ≥1.5 T for diagnosing or ruling out knee injuries or knee pathologies. The systematic literature research revealed more than 10,000 references, of which 1598 abstracts were reviewed and 87 full-text articles were retrieved. The further selection process resulted in the inclusion of four systematic reviews and six primary studies. No differences could be identified in the diagnostic performance of low- versus high-field MRI for the detection or exclusion of meniscal or cruciate ligament tears. Regarding the detection or grading of cartilage defects and osteoarthritis of the knee, the existing evidence suggests that high-field MRI is tolerably specific but not very sensitive, while there is literally no evidence for low-field MRI because only a few studies with small sample sizes and equivocal findings have been performed. We can recommend the use of low-field strength MRI systems in suspected meniscal or cruciate ligament injuries. This does, however, not apply to the diagnosis and grading of knee cartilage defects and osteoarthritis because of insufficient evidence. (orig.)

  10. Magnetic resonance tomography of the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Puig, Stefan; Kuruvilla, Yojena Chittazhathu Kurian; Ebner, Lukas [University Hospital, University of Berne, Department of Interventional, Pediatric and Diagnostic Radiology Inselspital, Berne (Switzerland); Endel, Gottfried [Main Association of Austrian Social Insurance Institutions, Vienna (Austria)

    2015-10-15

    To compare the diagnostic performance of magnetic resonance imaging (MRI) in terms of sensitivity and specificity using a field strength of <1.0 T (T) versus ≥1.5 T for diagnosing or ruling out knee injuries or knee pathologies. The systematic literature research revealed more than 10,000 references, of which 1598 abstracts were reviewed and 87 full-text articles were retrieved. The further selection process resulted in the inclusion of four systematic reviews and six primary studies. No differences could be identified in the diagnostic performance of low- versus high-field MRI for the detection or exclusion of meniscal or cruciate ligament tears. Regarding the detection or grading of cartilage defects and osteoarthritis of the knee, the existing evidence suggests that high-field MRI is tolerably specific but not very sensitive, while there is literally no evidence for low-field MRI because only a few studies with small sample sizes and equivocal findings have been performed. We can recommend the use of low-field strength MRI systems in suspected meniscal or cruciate ligament injuries. This does, however, not apply to the diagnosis and grading of knee cartilage defects and osteoarthritis because of insufficient evidence. (orig.)

  11. Pancreatitis: computed tomography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, P.J.A.; Sheridan, M.B. [Dept. of Clinical Radiology, St. James' s University Hospital, Leeds (United Kingdom)

    2000-03-01

    The value of CT in management of severe acute pancreatitis is well established. Some, but not all, experimental studies suggest a detrimental effect of intravenous iodinated contrast agents in acute pancreatitis, but although initial clinical data tends to support this, the positive advantages of enhanced CT outweigh the possible risks. Magnetic resonance imaging has been shown to be as effective as CT in demonstrating the presence and extent of pancreatic necrosis and fluid collections, and probably superior in indicating the suitability of such collections for percutaneous drainage. Image-guided intervention remains a key approach in the management of severely ill patients, and the indications, techniques and results of radiological intervention are reviewed herein. Both CT and MRI can be used to diagnose advanced chronic pancreatitis, with the recent addition of MRCP as a viable alternative to diagnostic endoscopic retrograde cholangiopancreatography (ERCP). Both MRCP and CT/MR imaging of the pancreatic parenchyma still have limitations in the recognition of the earliest changes of chronic pancreatitis - for which ERCP and tests of pancreatic function remain more sensitive - but the clinical significance of these minor changes remains contentious. (orig.)

  12. Potts disease: Diagnosis with magnetic resonance imaging

    International Nuclear Information System (INIS)

    The eponymously named Potts disease is a relatively rare form of Tuberculosis (TB) which affects the spine. TB of the spine is one of the earliest diseases known to man and in the 20th century was thought to be a disease which had been defeated by the advent of antitubercular drugs. Over the last two decades there have been several reports which indicate a revival of TB in both the developing and developed world. Factors which may be contributing to this are the spread of the HIV virus, increased immigration and the emergence of drug resistant strains of the TB bacteria. Potts disease has an insidious onset and often the radiographic findings are far advanced when a diagnosis is finally reached. MRI is able to detect changes to the vertebrae in Potts disease earlier than radiographs. This case report outlines the clinical presentation of a young male with Potts disease who was HIV negative, and the important role that MRI plays in diagnosis and therefore in appropriate and timely intervention. The typical magnetic resonance (MR) imaging features and the radiographic hallmarks of the disease will also be discussed.

  13. Neural network segmentation of magnetic resonance images

    Science.gov (United States)

    Frederick, Blaise

    1990-07-01

    Neural networks are well adapted to the task of grouping input patterns into subsets which share some similarity. Moreover once trained they can generalize their classification rules to classify new data sets. Sets of pixel intensities from magnetic resonance (MR) images provide a natural input to a neural network by varying imaging parameters MR images can reflect various independent physical parameters of tissues in their pixel intensities. A neural net can then be trained to classify physically similar tissue types based on sets of pixel intensities resulting from different imaging studies on the same subject. A neural network classifier for image segmentation was implemented on a Sun 4/60 and was tested on the task of classifying tissues of canine head MR images. Four images of a transaxial slice with different imaging sequences were taken as input to the network (three spin-echo images and an inversion recovery image). The training set consisted of 691 representative samples of gray matter white matter cerebrospinal fluid bone and muscle preclassified by a neuroscientist. The network was trained using a fast backpropagation algorithm to derive the decision criteria to classify any location in the image by its pixel intensities and the image was subsequently segmented by the classifier. The classifier''s performance was evaluated as a function of network size number of network layers and length of training. A single layer neural network performed quite well at

  14. Magnetic Resonance Imaging in Pediatric Epilepsy

    Directory of Open Access Journals (Sweden)

    R. Barikbin

    2008-01-01

    Full Text Available Epilepsy is a common neurological affliction of children. It carries an estimated annual incidence of up to one per 1,000, and a prevalence of up to 5 per 1,000 children. Children suffering from epilepsy have a significantly increased mortality rate. The major causes of death are the underlying cause of the epilepsy itself, associated neurological compromise, injuries, and status epilepticus."nNeuroimaging techniques have advanced the diagnosis, management, and understanding the pathophysiology of underlying the epilepsies. MRI is the technique of choice for investigation of patients with seizure disorders. MRI provides excellent anatomic information and tissue contrast, resulting in high sensitivity. MRI studies should be customized to answer the appropriate clinical questions. Functional imaging techniques including magnetic resonance spectroscopy and functional MRI are becoming increasingly important in the investigation and management of patients with seizures. These techniques permit noninvasive assessment of the epileptic substrate, functional status, ictal activity, blood flow changes, me-tabolism, and neuroreceptors. Application of these new techniques promises to advance our understanding and treatment of seizures in children. In this presentation we will address the MR findings of epilepsy in children.

  15. Focal liver lesions: Practical magnetic resonance imagingapproach

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    With the widespread of cross-sectional imaging, a growthof incidentally detected focal liver lesions (FLL) hasbeen observed. A reliable detection and characterizationof FLL is critical for optimal patient management.Maximizing accuracy of imaging in the context ofFLL is paramount in avoiding unnecessary biopsies,which may result in post-procedural complications. Atremendous development of new imaging techniqueshas taken place during these last years. Nowadays,Magnetic resonance imaging (MRI) plays a key rolein management of liver lesions, using a radiation-freetechnique and a safe contrast agent profile. MRI playsa key role in the non-invasive correct characterizationof FLL. MRI is capable of providing comprehensiveand highly accurate diagnostic information, withthe additional advantage of lack of harmful ionizingradiation. These properties make MRI the mainstay forthe noninvasive evaluation of focal liver lesions. In thispaper we review the state-of-the-art MRI liver protocol,briefly discussing different sequence types, the uniquecharacteristics of imaging non-cooperative patients anddiscuss the role of hepatocyte-specific contrast agents.A review of the imaging features of the most commonbenign and malignant FLL is presented, supplementedby a schematic representation of a simplistic practicalapproach on MRI.

  16. Magnetic Resonance Imaging of Pituitary Tumors.

    Science.gov (United States)

    Bonneville, Jean-François

    2016-01-01

    Magnetic Resonance Imaging (MRI) is currently considered a major keystone of the diagnosis of diseases of the hypothalamic-hypophyseal region. However, the relatively small size of the pituitary gland, its location deep at the skull base and the numerous physiological variants present in this area impede the precise assessment of the anatomical structures and, particularly, of the pituitary gland itself. The diagnosis of the often tiny lesions of this region--such as pituitary microadenomas--is then difficult if the MRI technology is not optimized and if potential artifacts and traps are not recognized. Advanced MRI technology can not only depict small lesions with greater reliability, but also help in the differential diagnosis of large tumors. In these, defining the presence or absence of invasion is a particularly important task. This review describes and illustrates the radiological diagnosis of the different tumors of the sellar region, from the common prolactinomas, nonfunctioning adenomas and Rathke's cleft cysts, to the less frequent and more difficult to detect corticotroph pituitary adenomas in Cushing's disease, and other neoplastic and nonneoplastic entities. Finally, some hints are given to facilitate the differential diagnosis of sellar lesions. PMID:27003878

  17. Statistical normalization techniques for magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Russell T. Shinohara

    2014-01-01

    Full Text Available While computed tomography and other imaging techniques are measured in absolute units with physical meaning, magnetic resonance images are expressed in arbitrary units that are difficult to interpret and differ between study visits and subjects. Much work in the image processing literature on intensity normalization has focused on histogram matching and other histogram mapping techniques, with little emphasis on normalizing images to have biologically interpretable units. Furthermore, there are no formalized principles or goals for the crucial comparability of image intensities within and across subjects. To address this, we propose a set of criteria necessary for the normalization of images. We further propose simple and robust biologically motivated normalization techniques for multisequence brain imaging that have the same interpretation across acquisitions and satisfy the proposed criteria. We compare the performance of different normalization methods in thousands of images of patients with Alzheimer's disease, hundreds of patients with multiple sclerosis, and hundreds of healthy subjects obtained in several different studies at dozens of imaging centers.

  18. Scatter-based magnetic resonance elastography

    International Nuclear Information System (INIS)

    Elasticity is a sensitive measure of the microstructural constitution of soft biological tissues and increasingly used in diagnostic imaging. Magnetic resonance elastography (MRE) uniquely allows in vivo measurement of the shear elasticity of brain tissue. However, the spatial resolution of MRE is inherently limited as the transformation of shear wave patterns into elasticity maps requires the solution of inverse problems. Therefore, an MRE method is introduced that avoids inversion and instead exploits shear wave scattering at elastic interfaces between anatomical regions of different shear compliance. This compliance-weighted imaging (CWI) method can be used to evaluate the mechanical consistency of cerebral lesions or to measure relative stiffness differences between anatomical subregions of the brain. It is demonstrated that CWI-MRE is sensitive enough to reveal significant elasticity variations within inner brain parenchyma: the caudate nucleus (head) was stiffer than the lentiform nucleus and the thalamus by factors of 1.3 ± 0.1 and 1.7 ± 0.2, respectively (P < 0.001). CWI-MRE provides a unique method for characterizing brain tissue by identifying local stiffness variations.

  19. Compression-sensitive magnetic resonance elastography

    Science.gov (United States)

    Hirsch, Sebastian; Beyer, Frauke; Guo, Jing; Papazoglou, Sebastian; Tzschaetzsch, Heiko; Braun, Juergen; Sack, Ingolf

    2013-08-01

    Magnetic resonance elastography (MRE) quantifies the shear modulus of biological tissue to detect disease. Complementary to the shear elastic properties of tissue, the compression modulus may be a clinically useful biomarker because it is sensitive to tissue pressure and poromechanical interactions. In this work, we analyze the capability of MRE to measure volumetric strain and the dynamic bulk modulus (P-wave modulus) at a harmonic drive frequency commonly used in shear-wave-based MRE. Gel phantoms with various densities were created by introducing CO2-filled cavities to establish a compressible effective medium. The dependence of the effective medium's bulk modulus on phantom density was investigated via static compression tests, which confirmed theoretical predictions. The P-wave modulus of three compressible phantoms was calculated from volumetric strain measured by 3D wave-field MRE at 50 Hz drive frequency. The results demonstrate the MRE-derived volumetric strain and P-wave modulus to be sensitive to the compression properties of effective media. Since the reconstruction of the P-wave modulus requires third-order derivatives, noise remains critical, and P-wave moduli are systematically underestimated. Focusing on relative changes in the effective bulk modulus of tissue, compression-sensitive MRE may be useful for the noninvasive detection of diseases involving pathological pressure alterations such as hepatic hypertension or hydrocephalus.

  20. Segmentation of neuroanatomy in magnetic resonance images

    Science.gov (United States)

    Simmons, Andrew; Arridge, Simon R.; Barker, G. J.; Tofts, Paul S.

    1992-06-01

    Segmentation in neurological magnetic resonance imaging (MRI) is necessary for feature extraction, volume measurement and for the three-dimensional display of neuroanatomy. Automated and semi-automated methods offer considerable advantages over manual methods because of their lack of subjectivity, their data reduction capabilities, and the time savings they give. We have used dual echo multi-slice spin-echo data sets which take advantage of the intrinsically multispectral nature of MRI. As a pre-processing step, a rf non-uniformity correction is applied and if the data is noisy the images are smoothed using a non-isotropic blurring method. Edge-based processing is used to identify the skin (the major outer contour) and the eyes. Edge-focusing has been used to significantly simplify edge images and thus allow simple postprocessing to pick out the brain contour in each slice of the data set. Edge- focusing is a technique which locates significant edges using a high degree of smoothing at a coarse level and tracks these edges to a fine level where the edges can be determined with high positional accuracy. Both 2-D and 3-D edge-detection methods have been compared. Once isolated, the brain is further processed to identify CSF, and, depending upon the MR pulse sequence used, the brain itself may be sub-divided into gray matter and white matter using semi-automatic contrast enhancement and clustering methods.

  1. Computed tomography and magnetic resonance colonography

    International Nuclear Information System (INIS)

    Colon cancer is the second leading cause of cancer death in the western world. Adenomatous colorectal polyps, which are found in 30-50% of Americans more than 50 years old, are recognized as important precursors of malignancy. Probably most of the invasive colon carcinomas arise from polyps. For this reason an early detection of these polyps and their complete removal is a recognized strategy for the prevention of colon cancer. So far no single method for an early diagnois of colon polyps or colon cancer offers high sensitivity and specificity along with low cost and good patient accccf Endo-opic colonoscopy allows the accurate detection of very small lesions and has since almost completely replaced fluooscopy. Cross-sectional imaging techniques, including magnetic resonance imaging (MRI) and computed tomography (CT), are increasingly being considered imaging modalities for the detection of colorectal polyps. CT and MR colonography are new techniques for imaging of the colon. In symptomatic patients, these new techniques show promising results for the detection of polyps equal to or larger than 1 cm in diameter. (author)

  2. Magnetic resonance imaging in brachial plexus injury.

    Science.gov (United States)

    Caranci, F; Briganti, F; La Porta, M; Antinolfi, G; Cesarano, E; Fonio, P; Brunese, L; Coppolino, F

    2013-08-01

    Brachial plexus injury represents the most severe nerve injury of the extremities. While obstetric brachial plexus injury has showed a reduction in the number of cases due to the improvements in obstetric care, brachial plexus injury in the adult is an increasingly common clinical problem. The therapeutic measures depend on the pathologic condition and the location of the injury: Preganglionic avulsions are usually not amenable to surgical repair; function of some denervated muscles can be restored with nerve transfers from intercostals or accessory nerves and contralateral C7 transfer. Postganglionic avulsions are repaired with excision of the damaged segment and nerve autograft between nerve ends or followed up conservatively. Magnetic resonance imaging is the modality of choice for depicting the anatomy and pathology of the brachial plexus: It demonstrates the location of the nerve damage (crucial for optimal treatment planning), depicts the nerve continuity (with or without neuroma formation), or may show a completely disrupted/avulsed nerve, thereby aiding in nerve-injury grading for preoperative planning. Computed tomography myelography has the advantage of a higher spatial resolution in demonstration of nerve roots compared with MR myelography; however, it is invasive and shows some difficulties in the depiction of some pseudomeningoceles with little or no communication with the dural sac. PMID:23949940

  3. Magnetic resonance imaging in retropharyngeal tendinitis

    Energy Technology Data Exchange (ETDEWEB)

    Ekbon, K.; Annell, K.; Traeff, J.; Torhall, J. (Soeder Hospital, Stockholm (Sweden))

    1994-08-01

    Seven consecutive patients with acute retropharyngeal tendinitis underwent plain X-ray and magnetic resonance imaging (MRI) of the cervical spine. All seven had marked soft tissue swelling anterior to C1 and C2 on plain X-ray, and soft tissue calcification at this level was present in five of them. On MRI, there was markedly increased signal intensity on T[sub 2]-weighted images in the acute phase and intermediate signal intensity on T[sub 1]-weighted images, anterior to the level of CI and C2, often extending as far down as C6. These changes correlated well with the soft tissue swelling seen on conventional X-ray of the cervical spine. The maximum mid-sagittal thickness of the soft issues was significantly greater in the tendinitis patients than in 12 control subjects free of symptoms from the pharynx or the cervical spine. Treatment with non-steroidal anti-inflammatory drugs rapidly alleviated symptoms, and at follow-up MRI showed regression or complete restitution of the changes. In conclusion, MRI can visualize the edematous changes in the longus colli muscle and adds useful diagnostic information in suspected cases of acute retropharyngeal tendinitis. 9 refs., 4 figs., 3 tabs.

  4. NUCLEAR MAGNETIC RESONANCE STUDIES OF URANOCENES

    Energy Technology Data Exchange (ETDEWEB)

    Luke, Wayne D.; Streitwieser, Jr., Andrew

    1979-12-01

    In the past several years a substantial amount of work has been devoted toward evaluation of the contact and pseudocontact contributions to the observed isotropic shifts in H nuclear magnetic resonance (NMR) spectra of uranium(IV) organometallic compounds. One reason for interest in this area arises from using the presence of contact shifts as a prcbe for covalent character in the uranium carbon bonds in these compounds. Several extensive {sup 1}H NNR studies on Cp{sub 3} U-X compounds and less extensive studies on uranocenes have been reported. Interpretation of these results suggests that contact shifts-contribute significantly to the observed isotropic shifts. Their presence has been taken as indicative of covalent character of metal carbon bonds in these systems, but agreement is not complete. In this paper we shall review critically the work reported on uranocenes in the light of recent results and report recent work on attempted separation of the observed isotropic shifts in alkyluranocenes into contact and pseudocontact components.

  5. Potts disease: Diagnosis with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pursey, Jacqueline [MRI Department, Gartnavel General Hospitial, 1053 Great Western road, Glasgow G12 0YN (United Kingdom)], E-mail: Jacqueline.pursey@ggc.scot.nhs.uk; Stewart, Sharon [School of Health and Social Care, Caledonian University, Glasgow (United Kingdom)

    2010-02-15

    The eponymously named Potts disease is a relatively rare form of Tuberculosis (TB) which affects the spine. TB of the spine is one of the earliest diseases known to man and in the 20th century was thought to be a disease which had been defeated by the advent of antitubercular drugs. Over the last two decades there have been several reports which indicate a revival of TB in both the developing and developed world. Factors which may be contributing to this are the spread of the HIV virus, increased immigration and the emergence of drug resistant strains of the TB bacteria. Potts disease has an insidious onset and often the radiographic findings are far advanced when a diagnosis is finally reached. MRI is able to detect changes to the vertebrae in Potts disease earlier than radiographs. This case report outlines the clinical presentation of a young male with Potts disease who was HIV negative, and the important role that MRI plays in diagnosis and therefore in appropriate and timely intervention. The typical magnetic resonance (MR) imaging features and the radiographic hallmarks of the disease will also be discussed.

  6. Magnetic Resonance Elastography: Inversions in Bounded Media

    Science.gov (United States)

    Kolipaka, Arunark; McGee, Kiaran P.; Manduca, Armando; Romano, Anthony J.; Glaser, Kevin J.; Araoz, Philip A.; Ehman, Richard L.

    2009-01-01

    Magnetic resonance elastography (MRE) is a noninvasive imaging technique capable of quantifying and spatially resolving the shear stiffness of soft tissues by visualization of synchronized mechanical wave displacement fields. However, MRE inversions generally assume that the measured tissue motion consists primarily of shear waves propagating in a uniform, infinite medium. This assumption is not valid in organs such as the heart, eye, bladder, skin, fascia, bone and spinal cord in which the shear wavelength approaches the geometric dimensions of the object. The aim of this study was to develop and test mathematical inversion algorithms capable of resolving shear stiffness from displacement maps of flexural waves propagating in bounded media such as beams, plates and spherical shells using geometry-specific equations of motion. MRE and finite element modeling (FEM) of beam, plate, and spherical shell phantoms of various geometries were performed. Mechanical testing of the phantoms agreed with the stiffness values obtained from FEM and MRE data and a linear correlation of r2 ≥ 0.99 was observed between the stiffness values obtained using MRE and FEM data. In conclusion, we have demonstrated new inversion methods for calculating shear stiffness that may be more appropriate for waves propagating in bounded media. PMID:19780146

  7. Very low field magnetic resonance imaging

    International Nuclear Information System (INIS)

    The aim of this thesis is to perform Magnetic Resonance Imaging at very low field (from 1 mT to 10 mT). A new kind of sensor called 'mixed sensor' has been used to achieve a good detectivity at low frequencies. Combining a superconducting loop and a giant magnetoresistance, those detectors have a competitive equivalent field noise compared to existing devices (Tuned coils, SQUIDs and Atomic Magnetometers). They have been combined with flux transformers to increase the coupling between the sample and the sensor. A complete study has been performed to adapt it to mixed sensors and then maximize the gain. This set has been incorporated in an existing small MRI device to test its robustness in real conditions. In parallel, several MRI sequences (GE, SE, FLASH, EPI,...) have been integrated and adapted to very low field requirements. They have been used to perform in-vivo three dimensional imaging and relaxometry studies on well known products to test their reliability. Finally, a larger setup adapted for full-head imaging has been designed and built to perform images on a larger working volume. (author)

  8. Magnetic resonance tomography in confirmed multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Uhlenbrock, D.; Dickmann, E.; Beyer, H.K.; Gehlen, W.

    1985-03-01

    The authors report on 21 cases of confirmed multiple sclerosis examined by both CT and magnetic resonance tomography. To safeguard the results, strict criteria were applied in accordance with the suggestions made by neurological work teams. Pathological lesions were seen in 20 patients; the MR image did not reveal anything abnormal in one case. On the average, 10.3 lesions were seen in the MR tomogram, whereas CT images showed on the average only 2.1 foci. The size and number of lesions in the MR tomogram were independent of the duration of the disease, the presented clinical symptoms, or the type of treatment at the time of examination. Evidently the sensitivity of MR tomography is very high in MS patients, but it has not yet been clarified to what extent this applies also to the specificity. Further research is mandatory. First experiences made by us show that lesions of a similar kind can also occur in diseases such as malignant lymphoma involving the brain, in vitamin B 12 deficiency syndrome, or encephalitis, and can become manifest in the MR tomogram.

  9. Bolus characteristics based on Magnetic Resonance Angiography

    Directory of Open Access Journals (Sweden)

    Bi Xiaoming

    2006-10-01

    Full Text Available Abstract Background A detailed contrast bolus propagation model is essential for optimizing bolus-chasing Computed Tomography Angiography (CTA. Bolus characteristics were studied using bolus-timing datasets from Magnetic Resonance Angiography (MRA for adaptive controller design and validation. Methods MRA bolus-timing datasets of the aorta in thirty patients were analyzed by a program developed with MATLAB. Bolus characteristics, such as peak position, dispersion and bolus velocity, were studied. The bolus profile was fit to a convolution function, which would serve as a mathematical model of bolus propagation in future controller design. Results The maximum speed of the bolus in the aorta ranged from 5–13 cm/s and the dwell time ranged from 7–13 seconds. Bolus characteristics were well described by the proposed propagation model, which included the exact functional relationships between the parameters and aortic location. Conclusion The convolution function describes bolus dynamics reasonably well and could be used to implement the adaptive controller design.

  10. Musculoskeletal magnetic resonance imaging: importance of radiography

    Energy Technology Data Exchange (ETDEWEB)

    Taljanovic, Mihra S.; Hunter, Tim B.; Fitzpatrick, Kimberly A. [Department of Radiology, The University of Arizona Health Sciences Center, 1501 N. Campbell Avenue, AZ 85724, Tucson (United States); Krupinski, Elizabeth A. [Department of Radiology, University of Arizona, 1609 N. Warren, Building 211, AZ 85724, Tucson (United States); Pope, Thomas L. [Department of Radiology, Medical University of South Carolina, 169 Ashley Avenue, P.O. Box 250322, SC 29425, Charleston (United States)

    2003-07-01

    To determine the usefulness of radiography for interpretation of musculoskeletal (MSK) magnetic resonance imaging (MRI) studies. In a 1-year period, 1,030 MSK MRI studies were performed in 1,002 patients in our institution. For each study, the interpreting radiologist completed a questionnaire regarding the availability and utility of radiographs, radiological reports and clinical information for the interpretation of the MRI study. Radiographs were essential, very important or added information in 61-75% of all MSK MRI cases. Radiographs were judged as essential for reading of MRI studies more often for trauma, infection/inflammation and tumors than for degenerative and miscellaneous/normal diagnoses ({chi}{sup 2}=60.95, df=16, P<0.0001). The clinical information was rated as ''essential'' or ''useful'' significantly more often than not ({chi}{sup 2}=93.07, df=16, P<0.0001). The clinical and MRI diagnoses were the same or partially concordant significantly more often for tumors than for trauma, infection/inflammation and degenerative conditions, while in the miscellaneous/normal group they were different in 64% of cases. When the diagnoses were different, there were more instances in which radiographs were not available. Radiographs are an important, and sometimes essential, initial complementary study for reading of MSK MRI examinations. It is highly recommended that radiographs are available when MSK MRI studies are interpreted. (orig.)

  11. Planar Atom Trap and Magnetic Resonance 'Lens' Designs

    CERN Document Server

    Barbic, M; Emery, T H; Scherer, A

    2007-01-01

    We present various planar magnetic designs that create points above the plane where the magnitude of the static magnetic field is a local minimum. Structures with these properties are of interest in the disciplines of neutral atom confinement, magnetic levitation, and magnetic resonance imaging. Each planar permanent magnet design is accompanied by the equivalent planar single non-crossing conductor design. Presented designs fall into three categories producing: a) zero value magnetic field magnitude point minima, b) non-zero magnetic field magnitude point minima requiring external bias magnetic field, and c) self-biased non-zero magnetic field magnitude point minima. We also introduce the Principle of Amperean Current Doubling in planar perpendicularly magnetized thin films that can be used to improve the performance of each permanent magnet design we present. Single conductor current-carrying designs are suitable for single layer lithographic fabrication, as we experimentally demonstrate. Finally, we presen...

  12. Dynamic nuclear polarization in a magnetic resonance force microscope experiment.

    Science.gov (United States)

    Issac, Corinne E; Gleave, Christine M; Nasr, Paméla T; Nguyen, Hoang L; Curley, Elizabeth A; Yoder, Jonilyn L; Moore, Eric W; Chen, Lei; Marohn, John A

    2016-04-01

    We report achieving enhanced nuclear magnetization in a magnetic resonance force microscope experiment at 0.6 tesla and 4.2 kelvin using the dynamic nuclear polarization (DNP) effect. In our experiments a microwire coplanar waveguide delivered radiowaves to excite nuclear spins and microwaves to excite electron spins in a 250 nm thick nitroxide-doped polystyrene sample. Both electron and proton spin resonance were observed as a change in the mechanical resonance frequency of a nearby cantilever having a micron-scale nickel tip. NMR signal, not observable from Curie-law magnetization at 0.6 T, became observable when microwave irradiation was applied to saturate the electron spins. The resulting NMR signal's size, buildup time, dependence on microwave power, and dependence on irradiation frequency was consistent with a transfer of magnetization from electron spins to nuclear spins. Due to the presence of an inhomogeneous magnetic field introduced by the cantilever's magnetic tip, the electron spins in the sample were saturated in a microwave-resonant slice 10's of nm thick. The spatial distribution of the nuclear polarization enhancement factor ε was mapped by varying the frequency of the applied radiowaves. The observed enhancement factor was zero for spins in the center of the resonant slice, was ε = +10 to +20 for spins proximal to the magnet, and was ε = -10 to -20 for spins distal to the magnet. We show that this bipolar nuclear magnetization profile is consistent with cross-effect DNP in a ∼10(5) T m(-1) magnetic field gradient. Potential challenges associated with generating and using DNP-enhanced nuclear magnetization in a nanometer-resolution magnetic resonance imaging experiment are elucidated and discussed. PMID:26964007

  13. Dynamic nuclear polarization in a magnetic resonance force microscope experiment.

    Science.gov (United States)

    Issac, Corinne E; Gleave, Christine M; Nasr, Paméla T; Nguyen, Hoang L; Curley, Elizabeth A; Yoder, Jonilyn L; Moore, Eric W; Chen, Lei; Marohn, John A

    2016-04-01

    We report achieving enhanced nuclear magnetization in a magnetic resonance force microscope experiment at 0.6 tesla and 4.2 kelvin using the dynamic nuclear polarization (DNP) effect. In our experiments a microwire coplanar waveguide delivered radiowaves to excite nuclear spins and microwaves to excite electron spins in a 250 nm thick nitroxide-doped polystyrene sample. Both electron and proton spin resonance were observed as a change in the mechanical resonance frequency of a nearby cantilever having a micron-scale nickel tip. NMR signal, not observable from Curie-law magnetization at 0.6 T, became observable when microwave irradiation was applied to saturate the electron spins. The resulting NMR signal's size, buildup time, dependence on microwave power, and dependence on irradiation frequency was consistent with a transfer of magnetization from electron spins to nuclear spins. Due to the presence of an inhomogeneous magnetic field introduced by the cantilever's magnetic tip, the electron spins in the sample were saturated in a microwave-resonant slice 10's of nm thick. The spatial distribution of the nuclear polarization enhancement factor ε was mapped by varying the frequency of the applied radiowaves. The observed enhancement factor was zero for spins in the center of the resonant slice, was ε = +10 to +20 for spins proximal to the magnet, and was ε = -10 to -20 for spins distal to the magnet. We show that this bipolar nuclear magnetization profile is consistent with cross-effect DNP in a ∼10(5) T m(-1) magnetic field gradient. Potential challenges associated with generating and using DNP-enhanced nuclear magnetization in a nanometer-resolution magnetic resonance imaging experiment are elucidated and discussed.

  14. Preoperative functional magnetic resonance imaging (fMRI) and transcranial magnetic stimulation (TMS)

    DEFF Research Database (Denmark)

    Hartwigsen, G.; Siebner, Hartwig R.; Stippich, C.

    2010-01-01

    of essential cortex, it cannot provide information preoperatively for surgical planning.Brain imaging techniques such as functional magnetic resonance imaging (fMRI), magnetoencephalography (MEG) and transcranial magnetic stimulation (TMS) are increasingly being used to localize functionally critical cortical...

  15. Beam induced electron cloud resonances in dipole magnetic fields

    Science.gov (United States)

    Calvey, J. R.; Hartung, W.; Makita, J.; Venturini, M.

    2016-07-01

    The buildup of low energy electrons in an accelerator, known as electron cloud, can be severely detrimental to machine performance. Under certain beam conditions, the beam can become resonant with the cloud dynamics, accelerating the buildup of electrons. This paper will examine two such effects: multipacting resonances, in which the cloud development time is resonant with the bunch spacing, and cyclotron resonances, in which the cyclotron period of electrons in a magnetic field is a multiple of bunch spacing. Both resonances have been studied directly in dipole fields using retarding field analyzers installed in the Cornell Electron Storage Ring. These measurements are supported by both analytical models and computer simulations.

  16. Resonant Raman Scattering from Silicon Nanoparticles Enhanced by Magnetic Response

    CERN Document Server

    Dmitriev, Pavel A; Milichko, Valentin A; Makarov, Sergey V; Mukhin, Ivan S; Samusev, Anton K; Krasnok, Alexander E; Belov, Pavel A; Kivshar, Yuri S

    2016-01-01

    Enhancement of optical response with high-index dielectric nanoparticles is attributed to the excitation of their Mie-type magnetic and electric resonances. Here we study Raman scattering from crystalline silicon nanoparticles and reveal that magnetic dipole modes have much stronger effect on the scattering than electric modes of the same order. We demonstrate experimentally a 140-fold enhancement of Raman signal from individual silicon spherical nanoparticles at the magnetic dipole resonance. Our results confirm the importance of the optically-induced magnetic response of subwavelength dielectric nanoparticles for enhancing light-matter interactions.

  17. Resonant Raman scattering from silicon nanoparticles enhanced by magnetic response.

    Science.gov (United States)

    Dmitriev, Pavel A; Baranov, Denis G; Milichko, Valentin A; Makarov, Sergey V; Mukhin, Ivan S; Samusev, Anton K; Krasnok, Alexander E; Belov, Pavel A; Kivshar, Yuri S

    2016-05-01

    Enhancement of optical response with high-index dielectric nanoparticles is attributed to the excitation of their Mie-type magnetic and electric resonances. Here we study Raman scattering from crystalline silicon nanoparticles and reveal that magnetic dipole modes have a much stronger effect on the scattering than electric modes of the same order. We demonstrate experimentally a 140-fold enhancement of the Raman signal from individual silicon spherical nanoparticles at the magnetic dipole resonance. Our results confirm the importance of the optically-induced magnetic response of subwavelength dielectric nanoparticles for enhancing light-matter interactions. PMID:27113352

  18. Imaging in Psoriatic Arthritis

    DEFF Research Database (Denmark)

    Poggenborg, René Panduro; Østergaard, Mikkel; Terslev, Lene

    2015-01-01

    Psoriatic arthritis (PsA) is an inflammatory joint disease characterized by arthritis and often enthesitis in patients with psoriasis, presenting a wide range of manifestations in various patterns. Imaging procedures are primarily conventional radiography, ultrasonography (US), and magnetic...

  19. Nuclear magnetic resonance data of C9H11ITe

    Science.gov (United States)

    Mikhova, B. M.

    This document is part of Part 6 `Organic Metalloid Compounds' of Subvolume D 'Chemical Shifts and Coupling Constants for Carbon-13' of Landolt-Börnstein III/35 'Nuclear Magnetic Resonance Data', Group III 'Condensed Matter'.

  20. Nuclear magnetic resonance data of C10H13ITe

    Science.gov (United States)

    Mikhova, B. M.

    This document is part of Part 6 `Organic Metalloid Compounds' of Subvolume D 'Chemical Shifts and Coupling Constants for Carbon-13' of Landolt-Börnstein III/35 'Nuclear Magnetic Resonance Data', Group III 'Condensed Matter'.

  1. Normal perinatal and paediatric postmortem magnetic resonance imaging appearances

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen J. [Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); UCL Institute of Child Health, London (United Kingdom); Barber, Joy L. [Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); Taylor, Andrew M. [Cardiorespiratory Division, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); UCL Institute of Cardiovascular Science, Centre for Cardiovascular Imaging, London (United Kingdom); Sebire, Neil J. [UCL Institute of Child Health, London (United Kingdom); Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom)

    2015-04-01

    As postmortem imaging becomes more widely used following perinatal and paediatric deaths, the correct interpretation of images becomes imperative, particularly given the increased use of postmortem magnetic resonance imaging. Many pathological processes may have similar appearances in life and following death. A thorough knowledge of normal postmortem changes is therefore required within postmortem magnetic resonance imaging to ensure that these are not mistakenly interpreted as significant pathology. Similarly, some changes that are interpreted as pathological if they occur during life may be artefacts on postmortem magnetic resonance imaging that are of limited significance. This review serves to illustrate briefly those postmortem magnetic resonance imaging changes as part of the normal changes after death in fetuses and children, and highlight imaging findings that may confuse or mislead an observer to identifying pathology where none is present. (orig.)

  2. Categorization of aortic aneurysm thrombus morphology by magnetic resonance imaging

    DEFF Research Database (Denmark)

    de la Motte, Louise; Pedersen, Mads Møller; Thomsen, Carsten;

    2013-01-01

    Magnetic resonance imaging (MRI) has been proposed for qualitative categorization of intraluminal thrombus morphology. We aimed to correlate the qualitative MRI categorization previously described to quantitative measurements of signal intensity and to compare morphological characteristics of int...

  3. Diffusion-weighted magnetic resonance imaging in ileocolonic Crohn's disease

    DEFF Research Database (Denmark)

    Juel, Mie A; Rafaelsen, Søren Rafael; Nathan, Torben;

    Background: Diffusion-weighted magnetic resonance imaging (dw- MRI) utilizes differences in the motion of water molecules between tissues for image formation without administration of contrast materials. Inflammation in the bowel wall slows water transit resulting in lower apparent diffusions...

  4. Soft Tissue Edema Around Musculoskeletal Sarcomas at Magnetic Resonance Imaging

    OpenAIRE

    Panicek, David M.; Schwartz, Lawrence H.

    1997-01-01

    The presence of soft tissue edema around a malignant musculoskeletal neoplasm can interfere with accurate local tumor staging at magnetic resonance imaging. This article discusses and illustrates such edema, emphasizing means for avoiding misinterpretation of edema and subsequent overstaging.

  5. Magnetic resonance tomography for trauma of the cervical spine

    International Nuclear Information System (INIS)

    Twenty patients who had suffered spinal trauma were examined by magnetic resonance tomography. Fifteen patients with first degree trauma in Erdmann's classification showed no abnormality. Magnetic resonance tomography of the cervical spine appears to be a suitable method for investigating patients with whiplash injuries. It is indicated following severe flexion injuries with subluxations and neurological symptoms, since it is the only method that can demonstrate the spinal cord directly and completely and show the extent of cord compression. For patients with thoracic trauma and rapidly developing neurological symptoms, magnetic resonance tomography is ideal for showing post-traumatic syringomyelia. Magnetic resonance tomography following whiplash injuries is recommended if plain films of the cervical spine show any abnormalities, as well as for the investigation of acute or sub-acute neurological abnormalities. The various findings are discussed. (orig.)

  6. [Magnetic resonance tomography in injuries of the cervical spine].

    Science.gov (United States)

    Meydam, K; Sehlen, S; Schlenkhoff, D; Kiricuta, J C; Beyer, H K

    1986-12-01

    Twenty patients who had suffered spinal trauma were examined by magnetic resonance tomography. Fifteen patients with first degree trauma in Erdmann's classification showed no abnormality. Magnetic resonance tomography of the cervical spine appears to be a suitable method for investigating patients with whiplash injuries. It is indicated following severe flexion injuries with subluxations and neurological symptoms, since it is the only method that can demonstrate the spinal cord directly and completely and show the extent of cord compression. For patients with thoracic trauma and rapidly developing neurological symptoms, magnetic resonance tomography is ideal for showing post-traumatic syringomyelia. Magnetic resonance tomography following whiplash injuries is recommended if plain films of the cervical spine show any abnormalities, as well as for the investigation of acute or sub-acute neurological abnormalities. The various findings are discussed. PMID:3025951

  7. Magnetic resonance tomography for trauma of the cervical spine

    Energy Technology Data Exchange (ETDEWEB)

    Meydam, K.; Sehlen, S.; Schlenkhoff, D.; Kiricuta, J.C.; Beyer, H.K.

    1986-12-01

    Twenty patients who had suffered spinal trauma were examined by magnetic resonance tomography. Fifteen patients with first degree trauma in Erdmann's classification showed no abnormality. Magnetic resonance tomography of the cervical spine appears to be a suitable method for investigating patients with whiplash injuries. It is indicated following severe flexion injuries with subluxations and neurological symptoms, since it is the only method that can demonstrate the spinal cord directly and completely and show the extent of cord compression. For patients with thoracic trauma and rapidly developing neurological symptoms, magnetic resonance tomography is ideal for showing post-traumatic syringomyelia. Magnetic resonance tomography following whiplash injuries is recommended if plain films of the cervical spine show any abnormalities, as well as for the investigation of acute or sub-acute neurological abnormalities. The various findings are discussed.

  8. Magnetic resonance imaging appearance of hypertensive encephalopathy in a dog

    OpenAIRE

    Bowman, Chloe A; Witham, Adrian; Tyrrell, Dayle; Long, Sam N

    2015-01-01

    A 16-year-old female spayed English Staffordshire terrier was presented for evaluation of a 10-month history of intermittent myoclonic episodes, and a one weeks history of short episodes of altered mentation, ataxia and collapse. Magnetic resonance imaging identified subcortical oedema, predominately in the parietal and temporal lobes and multiple cerebral microbleeds. Serum biochemistry, indirect blood pressure measurements and magnetic resonance imaging abnormalities were consistent with hy...

  9. Magnetic resonance imaging in entomology: a critical review

    OpenAIRE

    Hart, A.G.; Bowtell, R W; Köckenberger, W; Wenseleers, T.; Ratnieks, F.L.W.

    2005-01-01

    Magnetic resonance imaging (MRI) enables in vivo imaging of organisms. The recent development of the magnetic resonance microscope (MRM) has enabled organisms within the size range of many insects to be imaged. Here, we introduce the principles of MRI and MRM and review their use in entomology. We show that MRM has been successfully applied in studies of parasitology, development, metabolism, biomagnetism and morphology, and the advantages and disadvantages relative to other imaging technique...

  10. Cardiovascular magnetic resonance physics for clinicians: part I

    OpenAIRE

    Ridgway John P

    2010-01-01

    Abstract There are many excellent specialised texts and articles that describe the physical principles of cardiovascular magnetic resonance (CMR) techniques. There are also many texts written with the clinician in mind that provide an understandable, more general introduction to the basic physical principles of magnetic resonance (MR) techniques and applications. There are however very few texts or articles that attempt to provide a basic MR physics introduction that is tailored for clinician...

  11. Magnetic resonance studies of brain function and neurochemistry

    OpenAIRE

    Uǧurbil, K.; Adriany, G.; Andersen, P; Chen, W.; Gruetter, R.; Hu, X.; Merkle, H; Kim, D.-S.; Kim, S. -G.; Strupp, J.; Zhu, X H; Ogawa, S

    2000-01-01

    In the short time since its introduction, magnetic resonance imaging (MRI) has rapidly evolved to become an indispensable tool for clinical diagnosis and biomedical research. Recently, this methodology has been successfully used for the acquisition of functional, physiological, and biochemical information in intact systems, particularly in the human body. The ability to map areas of altered neuronal activity in the brain, often referred to as functional magnetic resonance imaging (fMRI), is p...

  12. Lymphoma of uterine cervix: magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Kanaan, Daniel; Constantino, Carolina Pesce Lamas; Souza, Rodrigo Canellas de, E-mail: daniel.kanaan@hotmail.com [Department of Radiology, Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Parente, Daniella Braz [Instituto D' Or de Pesquisa e Ensino, Rio de Janeiro, RJ (Brazil)

    2012-05-15

    Lymphoma of the cervix is a rare disease. About 1.0% to 1.5% of extranodal lymphomas originates in the female genital tract. The clinical presentation of this condition is nonspecific and magnetic resonance imaging is important for diagnostic elucidation. The present report describes the case of a 80-year-old patient with lumbar pain, whose magnetic resonance imaging showed a large uterine mass. The final diagnosis was lymphoma. (author)

  13. Magnetic resonance spectroscopy and imaging in cerebral ischemia

    International Nuclear Information System (INIS)

    In-vivo proton and phosphorus magnetic resonance spectroscopy was used to detect changes in cerebral metabolism during ischemia and other types of metabolic stress. Magnetic resonance imaging was performed in an animal model to observe morphological alterations during focal cerebral ischemia. Spectroscopy was performed in animal models with global ischemia, in volunteers during hyperventilation and pharmaco-logically altered cerebral perfusion, and in patients with acute and prolonged focal cerebral ischemia. (author). 396 refs.; 44 figs.; 14 tabs

  14. Implementation of Quantum Logic Gates by Nuclear Magnetic Resonance Spectroscopy

    Institute of Scientific and Technical Information of China (English)

    DU Jiang-Feng; WU Ji-Hui; SHI Ming-Jun; HAN Liang; ZHOU Xian-Yi; YE Bang-Jiao; WENG Hui-Ming; HAN Rong-Dian

    2000-01-01

    Using nuclear magnetic resonance techniques with a solution of cytosine molecules, we show an implementation of certain quantum logic gates (including NOT gate, square-root of NOT gate and controlled-NOT gate), which have central importance in quantum computing. In addition, experimental results show that nuclear magnetic resonance spectroscopy can efficiently measure the result of quantum computing without attendant wave-function collapse.

  15. The OMERACT MRI in Arthritis Working Group - Update on Status and Future Research Priorities

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Bird, Paul; Gandjbakhch, Frédérique;

    2015-01-01

    OBJECTIVE: To provide an update on the status and future research priorities of the Outcome Measures in Rheumatology (OMERACT) magnetic resonance imaging (MRI) in arthritis working group. METHODS: A summary is provided of the activities of the group within rheumatoid arthritis (RA), psoriatic...

  16. Patient perception of magnetic resonance arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Robbins, M.I.; Anzilotti, K.F. Jr.; Katz, L.D.; Lange, R.C. [Dept. of Diagnostic Radiology, Yale University School of Medicine, New Haven, CT (United States)

    2000-05-01

    Objective. Magnetic resonance (MR) arthrography has been demonstrated to be more accurate than MR imaging alone in the identification of a variety of musculoskeletal pathology. While the complication rate of intra-articular gadolinium: saline injection has been shown to be relatively low, MR arthrography is more invasive, painful, and costly, and less convenient, than MR imaging alone. The purpose of this study was to evaluate patients' perception of the fear and discomfort, and to assess their overall acceptance of the intra-articular gadolinium injection.Design and patients. Between October 1997 and January 1998, 113 outpatients who were referred to Yale-New Haven Hospital for MR arthrography of the ankle, elbow, hip, knee, shoulder, or wrist were asked to complete a questionnaire rating their fear of factors most commonly associated with the procedure including ''pain'', ''needles'', ''complications'', and ''discovery of results that would lead to surgery''. In addition, after having undergone the intra-articular gadolinium:saline injection, patients were asked to rate their perception of pain.Results. While many patients expressed fear of ''pain'' and ''needles'', after having undergone the injection their overall pain rating score was low. Only 6% actually found gadolinium arthrography more painful than expected.Conclusion. Despite the fact that patients expressed apprehension about certain aspects of MR arthrography, subjects who underwent the intra-articular gadolinium injection considered the discomfort less than expected. Clinicians should not hesitate to order MR arthrography because the accuracy of the procedure is high enough that patients accept the discomfort. (orig.)

  17. Recent advances in cardiac magnetic resonance.

    Science.gov (United States)

    Greulich, Simon; Arai, Andrew E; Sechtem, Udo; Mahrholdt, Heiko

    2016-01-01

    Cardiac magnetic resonance (CMR) is a non-invasive imaging modality that has rapidly emerged during the last few years and has become a valuable, well-established clinical tool. Beside the evaluation of anatomy and function, CMR has its strengths in providing detailed non-invasive myocardial tissue characterization, for which it is considered the current diagnostic gold standard. Late gadolinium enhancement (LGE), with its capability to detect necrosis and to separate ischemic from non-ischemic cardiomyopathies by distinct LGE patterns, offers unique clinical possibilities. The presence of LGE has also proven to be a good predictor of an adverse outcome in various studies. T2-weighted (T2w) images, which are supposed to identify areas of edema and inflammation, are another CMR approach to tissue characterization. However, T2w images have not held their promise owing to several technical limitations and potential physiological concerns. Newer mapping techniques may overcome some of these limitations: they assess quantitatively myocardial tissue properties in absolute terms and show promising results in studies for characterization of diffuse fibrosis (T1 mapping) and/or inflammatory processes (T2 mapping). However, these techniques are still research tools and are not part of the clinical routine yet. T2* CMR has had significant impact in the management of thalassemia because it is possible to image the amount of iron in the heart and the liver, improving both diagnostic imaging and the management of patients with thalassemia. CMR findings frequently have clinical impact on further patient management, and CMR seems to be cost effective in the clinical routine. PMID:27635240

  18. Magnetic resonance imaging of spinal dysraphism

    Energy Technology Data Exchange (ETDEWEB)

    Akino, Minoru; Isu, Toyohiko; Iwasaki, Yoshinobu; Abe, Hiroshi; Abe, Satoru; Miyasaka, Kazuo; Nomura, Mikio; Saito, Hisatoshi.

    1988-04-01

    Nineteen patients with lumbosacral spina bifida were studied by magnetic resonance imaging (MRI) and were divided into two groups: those with lumbosacral lipoma and those with meningomyelocele. All of the patients with meningomyelocele underwent surgery soon after birth for closure of the skin defect. Whenever possible, examination was not confined to the lumbosacral area but also included the brain and other portions of the spinal cord. Certain similarities and differences in pathology were ascertained in the two groups. The tethered cords were the same in both groups. However, Chiari malformations were observed only in patients with meningomyelocele, and hydrocephalus occurred only in patients with Chiari malformations. Syringomyelia and scoliosis were detected in both groups, but scoliosis was more prevalent in the meningomyelocele group. There appeared to be a correlation between scoliosis and syringomyelia; in five of the seven cases of syringomyelia, the locations of the scoliosis and syringomyelia were the same. With MRI, these complex pathologies, including tethered cord, syringomyelia, scoliosis, Chiari malformations, and hydrocephalus, were easily visualized. The superiority of MRI over conventional X-ray technology has been well established. First, a direct image of the spinal cord is obtained. Second, there is no necessity for injection of contrast material into the intrathecal space. Third, any scanning field is possible. There are also some disadvantages with MRI. First, the spatial resolution is inferior to that of high-resolution computed tomography. Second, MRI cannot provide information concerning bone cortex. Therefore, bone involvement cannot be accurately diagnosed. However, in the assessment of spinal dysraphism, MRI is an excellent diagnostic tool and should be the preferred method of diagnosing spinal dysraphism.

  19. Magnetic Resonance Features of Cerebral Malaria

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, P.; Sharma, R.; Kumar, S.; Kumar, U. (Dept. of Radiodiagnosis and Dept. of Medicine, All India Institute of Medical Sciences, New Delhi (India))

    2008-06-15

    Background: Cerebral malaria is a major health hazard, with a high incidence of mortality. The disease is endemic in many developing countries, but with a greater increase in tourism, occasional cases may be detected in countries where the disease in not prevalent. Early diagnosis and evaluation of cerebral involvement in malaria utilizing modern imaging modalities have an impact on the treatment and clinical outcome. Purpose: To evaluate the magnetic resonance (MR) features of patients with cerebral malaria presenting with altered sensorium. Material and Methods: We present the findings in three patients with cerebral malaria presenting with altered sensorium. MR imaging using a 1.5-Tesla unit was carried out. The sequences performed were 5-mm-thick T1-weighted, T2-weighted, fluid-attenuated inversion-recovery (FLAIR), and T2-weighted gradient-echo axial sequences, and sagittal and coronal FLAIR. Diffusion-weighted imaging was performed with b values of 0 and 1000 s/mm2, and apparent diffusion coefficient (ADC) maps were obtained. Results: Focal hyperintensities in the bilateral periventricular white matter, corpus callosum, occipital subcortex, and bilateral thalami were noticed on T2-weighted and FLAIR sequences. The lesions were more marked in the splenium of the corpus callosum. No enhancement on postcontrast T1-weighted MR images was observed. There was no evidence of restricted diffusion on the diffusion-weighted sequence and ADC map. Conclusion: MR is a sensitive imaging modality, with a role in the assessment of cerebral lesions in malaria. Focal white matter and corpus callosal lesions without any restricted diffusion were the key findings in our patients

  20. Magnetic resonance imaging of spinal dysraphism

    International Nuclear Information System (INIS)

    Nineteen patients with lumbosacral spina bifida were studied by magnetic resonance imaging (MRI) and were divided into two groups: those with lumbosacral lipoma and those with meningomyelocele. All of the patients with meningomyelocele underwent surgery soon after birth for closure of the skin defect. Whenever possible, examination was not confined to the lumbosacral area but also included the brain and other portions of the spinal cord. Certain similarities and differences in pathology were ascertained in the two groups. The tethered cords were the same in both groups. However, Chiari malformations were observed only in patients with meningomyelocele, and hydrocephalus occurred only in patients with Chiari malformations. Syringomyelia and scoliosis were detected in both groups, but scoliosis was more prevalent in the meningomyelocele group. There appeared to be a correlation between scoliosis and syringomyelia; in five of the seven cases of syringomyelia, the locations of the scoliosis and syringomyelia were the same. With MRI, these complex pathologies, including tethered cord, syringomyelia, scoliosis, Chiari malformations, and hydrocephalus, were easily visualized. The superiority of MRI over conventional X-ray technology has been well established. First, a direct image of the spinal cord is obtained. Second, there is no necessity for injection of contrast material into the intrathecal space. Third, any scanning field is possible. There are also some disadvantages with MRI. First, the spatial resolution is inferior to that of high-resolution computed tomography. Second, MRI cannot provide information concerning bone cortex. Therefore, bone involvement cannot be accurately diagnosed. However, in the assessment of spinal dysraphism, MRI is an excellent diagnostic tool and should be the preferred method of diagnosing spinal dysraphism. (author)

  1. Magnetic Resonance Imaging in Postprostatectomy Radiotherapy Planning

    International Nuclear Information System (INIS)

    Purpose: To investigate whether the use of magnetic resonance imaging (MRI) in prostate bed treatment planning could influence definition of the clinical target volume (CTV) and organs at risk. Methods and Materials: A total of 21 consecutive patients referred for prostate bed radiotherapy were included in the present retrospective study. The CTV was delineated according to the European Organization for Research and Treatment of Cancer recommendations on computed tomography (CT) and T1-weighted (T1w) and T2-weighted (T2w) MRI. The CTV magnitude, agreement, and spatial differences were evaluated on the planning CT scan after registration with the MRI scans. Results: The CTV was significantly reduced on the T1w and T2w MRI scans (13% and 9%, respectively) compared with the CT scans. The urinary bladder was drawn smaller on the CT scans and the rectum was smaller on the MRI scans. On T1w MRI, the rectum and urinary bladder were delineated larger than on T2w MRI. Minimal agreement was observed between the CT and T2w images. The main spatial differences were measured in the superior and superolateral directions in which the CTV on the MRI scans was 1.8–2.9 mm smaller. In the posterior and inferior border, no difference was seen between the CT and T1w MRI scans. On the T2w MRI scans, the CTV was larger in these directions (by 1.3 and 1.7 mm, respectively). Conclusions: The use of MRI in postprostatectomy radiotherapy planning resulted in a reduction of the CTV. The main differences were found in the superior part of the prostate bed. We believe T2w MRI enables more precise definition of prostate bed CTV than conventional planning CT.

  2. Can magnetic resonance spectroscopy differentiate endometrial cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jie; Cai, Shifeng; Han, Xue; Liu, Qingwei; Xin, Yinghui [Shandong University, Department of Radiology, Shandong Provincial Hospital, Jinan (China); Li, Changzhong; Yang, Chunrun [Shandong University, Department of Obstetrics and Gynecology, Shandong Provincial Hospital, Jinan (China); Sun, Xichao; Zong, Yuanyuan [Shandong University, Department of Pathology, Shandong Provincial Hospital, Jinan (China); Fu, Caixia [Siemens Shenzhen Magnetic Resonance Ltd., Siemens MRI Center, Shenzhen (China)

    2014-10-15

    To investigate whether the choline-containing compounds (Cho) obtained from three-dimensional {sup 1}H magnetic resonance (MR) spectroscopy can differentiate endometrial cancer (ECa) from benign lesions in endometria or in submucosa (BLs-ESm) and is associated with the aggressiveness of ECa. Fifty-seven patients (ECa, 38; BLs-ESm, 19) underwent preoperative multi-voxel MR spectroscopy at 3.0 T. The ratio of the sum of the Cho peak integral to the sum of the unsuppressed water peak integral (Cho/water) and the coefficient of variation (CV) used to describe the variability of Cho/water in one lesion were calculated. Mean Cho/water (±standard deviation [SD]) was (3.02 ± 1.43) x 10{sup -3} for ECa and (1.68 ± 0.33) x 10{sup -3} for BLs-ESm (p < 0.001). Mean Cho/water was (4.42 ± 1.53) x 10{sup -3} for type II ECa and (2.65 ± 1.17) x 10{sup -3} for type I ECa (p = 0.001). There were no significant differences among different stages of ECa (p = 0.107) or different grades of ECa (p = 0.142). The Cho/water was positively correlated with tumour stage (r = 0.386, p = 0.017) and size (r = 0.333, p = 0.041). The CV was also positively correlated with tumour stage (r = 0.537, p = 0.001) and size (r = 0.34, p = 0.037). The Cho/water can differentiate ECa from BLs-ESm and differentiate type II from type I ECa, but cannot differentiate different stages of ECa or different grades of ECa. Cho/water increased with the increase of tumour stage and size. (orig.)

  3. Magnetic Resonance Imaging of Normal Pressure Hydrocephalus.

    Science.gov (United States)

    Bradley, William G

    2016-04-01

    Normal pressure hydrocephalus (NPH) is a syndrome found in the elderly, which is characterized by ventriculomegaly and deep white matter ischemia (DWMI) on magnetic resonance imaging (MRI) and the clinical triad of gait disturbance, dementia, and urinary incontinence. NPH has been estimated to account for up to 10% of cases of dementia and is significant because it is treatable by ventriculoperitoneal shunting. Patients with a known cause of chronic communicating hydrocephalus, that is, meningitis or hemorrhage, tend to respond better than patients with the so-called "idiopathic" form, most likely because of poor selection criteria in the past. Good response to shunting has been associated with hyperdynamic cerebrospinal fluid (CSF) flow through the aqueduct. In the early days of MRI, patients with a large CSF flow void extending from the foramen of Monro through the aqueduct to the fourth ventricle had an excellent chance of responding to ventriculoperitoneal shunting (P < 0.003). Today, we use phase-contrast MRI to measure the volume of CSF flowing through the aqueduct in either direction over a cardiac cycle. When this aqueductal CSF stroke volume is sufficiently elevated, there is an excellent chance of shunt responsiveness (100% positive predictive value in 1 study). Idiopathic NPH appears to be a "two-hit" disease-benign external hydrocephalus (BEH) in infancy followed by DWMI in late adulthood. As BEH occurs when the sutures are still open, these infants present with large heads, a finding also noted in patients with NPH. Although BEH has been attributed to immature arachnoidal granulations with decreased CSF resorptive capacity, this now appears to be permanent and may lead to a parallel pathway for CSF resorption via the extracellular space of the brain. With DWMI, the myelin lipid is lost, exposing the polar water molecules to myelin protein, increasing resistance to CSF outflow and leading to backing up of CSF and hydrocephalus. PMID:27063662

  4. Functional magnetic resonance imaging of the lung.

    Science.gov (United States)

    Biederer, J; Heussel, C P; Puderbach, M; Wielpuetz, M O

    2014-02-01

    Beyond being a substitute for X-ray, computed tomography, and scintigraphy, magnetic resonance imaging (MRI) inherently combines morphologic and functional information more than any other technology. Lung perfusion: The most established method is first-pass contrast-enhanced imaging with bolus injection of gadolinium chelates and time-resolved gradient-echo (GRE) sequences covering the whole lung (1 volume/s). Images are evaluated visually or semiquantitatively, while absolute quantification remains challenging due to the nonlinear relation of T1-shortening and contrast material concentration. Noncontrast-enhanced perfusion imaging is still experimental, either based on arterial spin labeling or Fourier decomposition. The latter is used to separate high- and low-frequency oscillations of lung signal related to the effects of pulsatile blood flow. Lung ventilation: Using contrast-enhanced first-pass perfusion, lung ventilation deficits are indirectly identified by hypoxic vasoconstriction. More direct but still experimental approaches use either inhalation of pure oxygen, an aerosolized contrast agent, or hyperpolarized noble gases. Fourier decomposition MRI based on the low-frequency lung signal oscillation allows for visualization of ventilation without any contrast agent. Respiratory mechanics: Time-resolved series with high background signal such as GRE or steady-state free precession visualize the movement of chest wall, diaphragm, mediastinum, lung tissue, tracheal wall, and tumor. The assessment of volume changes allows drawing conclusions on regional ventilation. With this arsenal of functional imaging capabilities at high spatial and temporal resolution but without radiation burden, MRI will find its role in regional functional lung analysis and will therefore overcome the sensitivity of global lung function analysis for repeated short-term treatment monitoring. PMID:24481761

  5. GEOCHEMICAL CONTROLS ON NUCLEAR MAGNETIC RESONANCE MEASUREMENTS

    International Nuclear Information System (INIS)

    Proton nuclear magnetic resonance (NMR) is used in the Earth Sciences as a means of obtaining information about the molecular-scale environment of fluids in porous geological materials. Laboratory experiments were conducted to advance our fundamental understanding of the link between the NMR response and the geochemical properties of geological materials. In the first part of this research project, we studied the impact of both the surface-area-to-volume ratio (S/V) of the pore space and the surface relaxivity on the NMR response of fluids in sand-clay mixtures. This study highlighted the way in which these two parameters control our ability to use NMR measurements to detect and quantify fluid saturation in multiphase saturated systems. The second part of the project was designed to explore the way in which the mineralogic form of iron, as opposed to simply the concentration of iron, affects the surface relaxation rate and, more generally, the NMR response of porous materials. We found that the magnitude of the surface relaxation rate was different for the various iron-oxide minerals because of changes in both the surface-area-to-volume ratio of the pore space, and the surface relaxivity. Of particular significance from this study was the finding of an anomalously large surface relaxivity of magnetite compared to that of the other iron minerals. Differences in the NMR response of iron minerals were seen in column experiments during the reaction of ferrihydrite-coated quartz sand with aqueous Fe(II) solutions to form goethite, lepidocrocite and magnetite; indicating the potential use of NMR as a means of monitoring geochemical reactions. The final part of the research project investigated the impact of heterogeneity, at the pore-scale, on the NMR response. This work highlighted the way in which the geochemistry, by controlling the surface relaxivity, has a significant impact on the link between NMR data and the microgeometry of the pore space.

  6. Research progress of magnetic resonance imaging contrast agents

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Magnetic resonance imaging (MRI) is a clinical diagnostic modality, which has become popular in hospitals around the world. Approximately 30% of MRI exams include the use of contrast agents. The research progress of the paramagnetic resonance imaging contrast agents was described briefly. Three important approaches in the soluble paramagnetic resonance imaging contrast agents design including nonionic, tissue-specific and macromolecular contrast agents were investigated. In addition, the problems in the research and development in future were discussed.

  7. 高频彩色多普勒超声与MRI在早期类风湿关节炎诊断中的价值%Value of high frequency ultrasonography and nucler magnetic resonance imaging in the early diagnosis of rheumatoid arthritis

    Institute of Scientific and Technical Information of China (English)

    王明玉; 王宪斌; 孙雪辉; 刘奉立; 黄生传

    2014-01-01

    目的 探讨高频彩色多普勒超声(HFUS)及MRI在早期类风湿关节炎(RA)患者关节病变检测中的应用价值.方法 回顾性分析2010年1-12月在山东烟台毓璜顶医院确诊的39例RA患者的临床资料,男20例,女19例,平均年龄(51.8±2.2)岁.所有患者双手、双腕均行HFUS、MR检查,重点观察有无骨侵蚀、骨髓水肿、滑膜增殖、滑膜血流、关节积液、肌腱炎等影像表现,并对两种检查方法的结果采用x2检验进行对比分析.结果 共检查关节1 248个,HFUS和MRI在观察骨侵蚀[5.1% (44/858) vs 4.1% (35/858),x2=1.075,P>0.05]、肌腱炎[4.6% (18/390) vs 1.5%(14/390),x2=0.521,P>0.05]、腱鞘水肿[9.5% (37/390) vs 7.7% (30/390),x2=0.800,P>0.05]方面的检出率差异无统计学意义;HFUS在观察关节滑膜增殖[15.4% (132/858) vs 7.7%(66/858),x2=24.870,P<0.01]、关节积液[10.4%(89/858) vs 6.1%(52/858),x2=10.578,P<0.05]方面明显的检出率优于MRI; MRI在观察骨髓水肿方面[0% (0/858)vs 5.5% (47/858),x2=48.324,P<0.05]优于HFUS.结论 HFUS在检测早期RA患者病变关节的骨侵蚀、肌腱炎、腱鞘水肿、滑膜增殖、关节积液等方面,与MRI具有等同、甚至更优异的诊断价值.%Objective To investigate the value of high frequency ultrasonography (HFUS) and nucler magnetic resonance imaging (MRI) in the early diagnosis of rheumatoid arthritis(RA).Methods The data of 39 consecutive patients with RA admitted in Yantai Yuhuangding hospital from January 2010 to December 2010 were retrospectively studied.In 39 cases of patients,males were 20 cases,female were 19 cases,the average age was (51.8 ±2.2) years.Bilateral bilateral wrist and hands jionts were examined by HFUS and MRI.Bone erosion,bone marrow edema,synovial proliferation,synovial blood flow,jiont effusion and tendinitis were received and the differences between the two examination results were compared.Chi-square test was used for statistical analysis

  8. 双重滤过血浆置换联合免疫抑制剂治疗对重度活动性类风湿关节炎患者磁共振成像的影响%Magnetic resonance imaging outcomes of double filtration plasmapheresis combined with immunosuppressive agents in patients with high active rheumatoid arthritis

    Institute of Scientific and Technical Information of China (English)

    于笑霞; 王立新; 张学武; 孙凤艳; 卢伟伟; 张淑敏; 戴士林

    2010-01-01

    Objective To evaluate the efficacy of double filtration plasmapheresis (DFPP) combined with immunosuppressive agents (leflunomide plus methotrexate) on synovitis in magnetic resonance imaging (MRI) in patients with high active rheumatoid arthritis (RA). Methods Fifty eight patients with RA (disease duration 6 months to 12 years) were randomly divided. Thirty-one were randomized to the treatment group and 27 were randomized to the control group. All patients received leflunomide 10 mg, two times daily; plus methotrexate 15 mg orally once weekly. DFPP was performed in the treatment group once 1-2 weeks for 3-4 sessions. Control patients did not receive DFPP. All patients underwent contrast-enhanced MRI of the right wrist at the baseline and 6 months, 1 month in the treatment group. The signs including synovitis pannus, bone marrow edema and effusion were observed on MRI. The scoring of synovial hypertrophy, pannus, bone marrow edema were measured according to the outcome measures in RA MRI scoring system. Comparisons between groups were performed with paired-samples t test and independent-sample t test. Results The MRI synovitis score, MRI pannus score and MRI bone marrow edema in the treatment group was (1.4±1.6), (0.13± 0.35) and (5±4) respectively,so was significantly lower than that of the control group [respectively for (7.9± 1.3), (2.76±0.43), (16±12),P0.05). Conclusion DFPP combined with immunosuppressive agents can significantly improve synovitis in MRI in patients with high active RA. Improvement of the signs of MRI is later than that in the clinic. So imaging assessment may be necessary for accurate evaluation of disease status and selection of therapy.%目的 探讨双重滤过血浆置换(DFPP)联合免疫抑制剂(来氟米特+甲氨蝶呤)治疗对重度活动性类风湿关节炎(RA)患者磁共振成像(MRI)的影响.方法 纳入58例RA患者,病程6个月至12年,采用计算机自动生成的随机号,将患者随机分为治疗组和对照

  9. Established rheumatoid arthritis - new imaging modalities

    DEFF Research Database (Denmark)

    McQueen, Fiona M; Østergaard, Mikkel

    2007-01-01

    New imaging modalities are assuming an increasingly important role in the investigation and management of rheumatoid arthritis. It is now possible to obtain information about all tissues within the joint in three dimensions using tomographic techniques such as magnetic resonance imaging (MRI...

  10. Psoas abscess with septic arthritis of the hip: a case report.

    Science.gov (United States)

    Belet, Nurşen; Akyurt, Büşra; Karlı, Arzu; Gülman, Birol; Selçuk, Mustafa Bekir; Şensoy, Gülnar

    2014-01-01

    Psoas abscess associated with septic arthritis of the hip is unusual in infants. A 12-month-old infant presented with the complaints of fever, left hip pain and limp. Magnetic resonance imaging revealed left psoas abscess accompanied by septic arthritis of the hip. In this report, we present a case of psoas abscess with hip septic arthritis in an infant, and we describe the clinical and radiological findings and treatment of this case.

  11. Magnetic resonance velocimetry: applications of magnetic resonance imaging in the measurement of fluid motion

    Science.gov (United States)

    Elkins, Christopher J.; Alley, Marcus T.

    2007-12-01

    Magnetic resonance velocimetry (MRV) is a non-invasive technique capable of measuring the three-component mean velocity field in complex three-dimensional geometries with either steady or periodic boundary conditions. The technique is based on the phenomenon of nuclear magnetic resonance (NMR) and works in conventional magnetic resonance imaging (MRI) magnets used for clinical imaging. Velocities can be measured along single lines, in planes, or in full 3D volumes with sub-millimeter resolution. No optical access or flow markers are required so measurements can be obtained in clear or opaque MR compatible flow models and fluids. Because of its versatility and the widespread availability of MRI scanners, MRV is seeing increasing application in both biological and engineering flows. MRV measurements typically image the hydrogen protons in liquid flows due to the relatively high intrinsic signal-to-noise ratio (SNR). Nonetheless, lower SNR applications such as fluorine gas flows are beginning to appear in the literature. MRV can be used in laminar and turbulent flows, single and multiphase flows, and even non-isothermal flows. In addition to measuring mean velocity, MRI techniques can measure turbulent velocities, diffusion coefficients and tensors, and temperature. This review surveys recent developments in MRI measurement techniques primarily in turbulent liquid and gas flows. A general description of MRV provides background for a discussion of its accuracy and limitations. Techniques for decreasing scan time such as parallel imaging and partial k-space sampling are discussed. MRV applications are reviewed in the areas of physiology, biology, and engineering. Included are measurements of arterial blood flow and gas flow in human lungs. Featured engineering applications include the scanning of turbulent flows in complex geometries for CFD validation, the rapid iterative design of complex internal flow passages, velocity and phase composition measurements in

  12. Magnetic resonance imaging for ankylosing spondylitis

    International Nuclear Information System (INIS)

    Ankylosing spondylitis (AS) is the prototypical form of the spondyloarthropathies, which at a prevalence of 2% is among the most frequent rheumatic diseases. Spondyloarthropathy comprises the following five disorders: AS, reactive arthritis, psoriatic arthritis, enteropathic arthritis in Crohn's disease, and ulcerosing colitis as well as undifferentiated spondyloarthropathy. In 99% of the patients with AS initial abnormal findings affect the sacroiliac joints. The radiographic changes required for diagnosing AS occur as late as 5-9 years after the onset of clinical symptoms. MRI of the sacroiliac joints reliably demonstrates both chronic inflammatory changes (erosions, sclerotic changes, bone bridges) and acute inflammatory changes (synovitis, capsulitis, osteitis) and allows for grading the chronicity and acuity of such changes. Enthesitis of the interosseous ligaments of the retroarticular space is a manifestation of AS. Spondylodiscitis (Andersson 1937) may occur as an inflammatory or non-inflammatory process (transdiscal fatigue fracture). Inflammations of the facet and costospinal joints developing into ankylosis are typical of AS. Changes of the vertebral bodies occur as anterior (Romanus 1952), posterior, and marginal spondylitis. All forms of spondyloarthropathies are furthermore characterized by asymmetrical synovitis of the large joints, particularly of the legs (gonarthritis, coxitis, tarsitis, peripheral oligoarthritis), rheumatic fibroosteitis (pelvic enthesitis, rheumatic calcaneopathy), and peri- and synchrondritis of the public symphisis and sternal synchondrosis. Since early inflammatory changes of the spinal column and of the extravertebral localizations in AS are demonstrated by MRI before they become apparent on radiographs, and thereby the diagnostic gap could be closed, the early use of MRI for diagnostic and follow-up is commendable, when new therapeutical options like the so-called 'biologicals' are employed. (orig.)

  13. The contemporary imaging methods of arthritis of the knee: algorithm of radiological examination

    International Nuclear Information System (INIS)

    Arthritis is a common term used for over 50 different joint diseases. Arthritis of the knee from the data of traumatologists takes about 16-22% of all arthritis. The precise diagnosis in early stage is very important to prevent such severe complications of arthritis as ankylosis and others because certain problems require immediate attention and prompt treatment. The aim of the study was to create an algorithm for precise diagnosis of arthritis in early stage taking in account clinics, possible cause of the arthritis and potentialities and informatively of the new radiological equipment. There were analysed 43 conventional radiograms, 10 ultra sonograms, 5 computer tomograms, 3 magnetic resonance and 7 radionuclide images of the patients with different stages and causes of the arthritis of the knee. The findings were correlated with literature data. From data of the study authors conclude that in the early stage of the arthritis the conventional radiology findings can be negative. If arthritis goes with excess fluid or cysts in the joint and also in paediatric praxis it might be more convenient to start examinations with ultrasonography. If there is clinical suspicion of bone marrow, tendon or cartilage structures involvement must be used magnetic resonance. To detect more precise destructive cavities or localisation of squirmiest the computer tomography should be performed. According to analysis for precise early radiological diagnosis and for follow up of the arthritis of the knee its treatment, authors made up algorithm for the patients with arthritis of the knee depending of the clinics and radiological findings

  14. Resonant Spin Wave Excitation by Terahertz Magnetic Near-field Enhanced with Split Ring Resonator

    CERN Document Server

    Mukai, Y; Yamamoto, T; Kageyama, H; Tanaka, K

    2014-01-01

    Excitation of antiferromagnetic spin waves in HoFeO$_{3}$ crystal combined with a split ring resonator (SRR) is studied using terahertz (THz) electromagnetic pulses. The magnetic field in the vicinity of the SRR induced by the incident THz electric field component excites and the Faraday rotation of the polarization of a near-infrared probe pulse directly measures oscillations that correspond to the antiferromagnetic spin resonance mode. The good agreement of the temperature-dependent magnetization dynamics with the calculation using the two-lattice Landau-Lifshitz-Gilbert equation confirms that the spin wave is resonantly excited by the THz magnetic near-field enhanced at the LC resonance frequency of the SRR, which is 20 times stronger than the incident magnetic field.

  15. Magnetic resonance imaging of tumor oxygenation and metabolic profile

    DEFF Research Database (Denmark)

    Krishna, Murali C.; Matsumoto, Shingo; Saito, Keita;

    2013-01-01

    an exogenous contrast agent: electron paramagnetic resonance imaging (EPRI) and Overhauser magnetic resonance imaging (OMRI). Tumor metabolic profile can be assessed by a third method, hyperpolarized metabolic MR, based on injection of hyperpolarized biological molecules labeled with 13C or 15N and MR...... which can characterize such features non-invasively and repeatedly will be of significant value in planning treatment as well as monitoring response to treatment. The three techniques based on magnetic resonance imaging (MRI) are reviewed here. Tumor pO2 can be measured by two MRI methods requiring...

  16. Terahertz Magnetic Mirror Realized with Dielectric Resonator Antennas.

    Science.gov (United States)

    Headland, Daniel; Nirantar, Shruti; Withayachumnankul, Withawat; Gutruf, Philipp; Abbott, Derek; Bhaskaran, Madhu; Fumeaux, Christophe; Sriram, Sharath

    2015-11-25

    Single-crystal silicon is bonded to a metal-coated substrate and etched in order to form an array of microcylinder passive terahertz dielectric resonator antennas (DRAs). The DRAs exhibit a magnetic response, and hence the array behaves as an efficient artificial magnetic conductor (AMC), with potential for terahertz antenna and sensing applications.

  17. The Nobel Prize in Medicine for Magnetic Resonance Imaging

    Science.gov (United States)

    Fry, Charles G.

    2004-01-01

    Nobel Prize in Medicine awarded in December 2003 to chemist Paul C. Lauterbur and physicist Peter Mansfield for the development of magnetic resonance imaging (MRI), a long overdue recognition of the huge impact MRI has had in medical diagnostics and research is mentioned. MRI was derived, and remains an extension of nuclear magnetic resonance…

  18. A Quantum Mechanical Review of Magnetic Resonance Imaging

    CERN Document Server

    Odaibo, Stephen G

    2012-01-01

    In this paper, we review the quantum mechanics of magnetic resonance imaging (MRI). We traverse its hierarchy of scales from the spin and orbital angular momentum of subatomic particles to the ensemble magnetization of tissue. And we review a number of modalities used in the assessment of acute ischemic stroke and traumatic brain injury.

  19. In vivo magnetic resonance spectroscopy: basic methodology and clinical applications.

    NARCIS (Netherlands)

    Graaf, M. van der

    2010-01-01

    The clinical use of in vivo magnetic resonance spectroscopy (MRS) has been limited for a long time, mainly due to its low sensitivity. However, with the advent of clinical MR systems with higher magnetic field strengths such as 3 Tesla, the development of better coils, and the design of optimized ra

  20. Parametric resonance induced chaos in magnetic damped driven pendulum

    Science.gov (United States)

    Khomeriki, Giorgi

    2016-07-01

    A damped driven pendulum with a magnetic driving force, appearing from a solenoid, where ac current flows is considered. The solenoid acts on the magnet, which is located at a free end of the pendulum. In this system the existence and interrelation of chaos and parametric resonance is theoretically examined. Derived analytical results are supported by numerical simulations and conducted experiments.

  1. A sup 1 H nuclear magnetic resonance study of structural and organisational changes in the cell

    CERN Document Server

    Tunnah, S K

    2000-01-01

    Increasing importance is being placed on understanding the role of membrane lipids in many different areas of biochemistry. It is of interest to determine what interactions may occur between membrane lipids and drug species. Furthermore, an increasing body of evidence suggests that membrane lipids are involved in the pathology of numerous diseases such as rheumatoid arthritis, cancer and HIV. Clearly, the more information available on the mechanisms involved in diseases, the greater the potential for identifying a cure or even a prevention. sup 1 H nuclear magnetic resonance (NMR) spectroscopy was used to study the alterations in membrane lipid organisation and structure in intact, viable cultured cells. Changes in the sup 1 H NMR spectra and the spin-lattice relaxation measurements of the human K562 and the rat FRTL-5 cell lines were observed on the addition of the fatty acid species: triolein, evening primrose oil, arachidonic acid and ITF 1779. Results indicate that the membrane lipids are reorganised to a...

  2. Radiation dosimetry using magnetic resonance imaging

    International Nuclear Information System (INIS)

    A new dosimetry system for 3D dose distribution measurements based on the Fricke dosimeter and magnetic resonance imaging (MRI) has been developed. The dosimeter consists of a ferrous sulphate solution incorporated in an agarose gel, which together constitute the dosimeter gel. The absorbed dose to the gel is measured by means of the proton spin-lattice relaxation rate, 1/T1 in an MR scanner. The dose distribution to an arbitrary slice within a dosimeter gel phantom can thus be determined. The chemical yield of the dosimeter gel is significantly higher than that of the for Fricke solution, and is strongly dependent of the initial ferrous sulphate concentration, assuming that the gel is bubbled with oxygen during preparation. A gel of 1.5 mM [Fe2+] and 50 mM [H2SO4] has a sensitivity of 0.108 s-1Gy-1 and is linear up to 50 Gy. The dosimeter gel has uniform dose response over large volumes. Above 50 mM[H2SO4] the yield increases only slightly, but the gel strength decreases and results in gel phantoms with non-uniform dose response. Below 50 mM[H2SO4] the sensitivity of the dosimeter falls rapidly due to the decreased relaxivity of the ferric ions. The high chemical yield can be explained by a chain reaction and a reaction scheme is accordingly proposed. The dosimeter gel shows no dependence on dose rate or radiation quality and can be regarded as water-equivalent with respect to the interaction of the radiation. The diffusion coefficient of the ferric ions in the agarose gel is 1.19x10-2 cm2/h. The diffusion blurs the dosimeteric image, but poses only a minor problem if the MR measurements are completed within the first two hours after irradiation. Dose distribution data from external radiation therapy units have been determined using the dosimeter gel and MRI with good accuracy, but the precision is poor, about 5-10%. (au) (84 refs.)

  3. Tools and methods for teaching magnetic resonance concepts and techniques

    DEFF Research Database (Denmark)

    Hanson, Lars G.

    2012-01-01

    Teaching of MRI methodology can be challenging for teachers as well as students. To support student learning, two graphical simulators for exploration of basic magnetic resonance principles are here introduced. The first implements a simple compass needle analogy implemented for day one of NMR...... and MRI education. After a few minutes of use, any user with minimal experience of magnetism will be able to explain the basic magnetic resonance principle. A second piece of software, the Bloch Simulator, aims much further, as it can be used to demonstrate and explore a wide range of phenomena including...

  4. A Spectral-Scanning Magnetic Resonance Imaging (MRI) Integrated System

    OpenAIRE

    Hassibi, Arjang; Babakhani, Aydin; Hajimiri, Ali

    2008-01-01

    An integrated spectral-scanning magnetic resonance imaging (MRI) technique is implemented in a 0.12μm SiGe BiCMOS process. This system is designed for small-scale MRI applications with non-uniform and low magnetic fields. The system is capable of generating customized magnetic resonance (MR) excitation signals, and also recovering the MR response using a coherent direct conversion receiver. The operation frequency is tunable from DC to 37MHz for wide-band MRI and up to...

  5. Three-Tesla magnetic resonance elastography for hepatic fibrosis: Comparison with diffusion-weighted imaging and gadoxetic acid-enhanced magnetic resonance imaging

    OpenAIRE

    Park, Hee Sun; Kim, Young Jun; Yu, Mi Hye; Choe, Won Hyeok; Jung, Sung Il; Jeon, Hae Jeong

    2014-01-01

    AIM: To evaluate the feasibility of 3-Tesla magnetic resonance elastography (MRE) for hepatic fibrosis and to compare that with diffusion-weighted imaging (DWI) and gadoxetic acid-enhanced magnetic resonance (MR) imaging.

  6. Tunable resonant transmission of electromagnetic waves through a magnetized plasma.

    Science.gov (United States)

    Kee, Chul-Sik; Li, Shou-Zhe; Kim, Kihong; Lim, H

    2003-03-01

    We theoretically investigate the resonant transmission of circularly polarized electromagnetic waves in the electromagnetic stop band of a magnetized plasma slab using the invariant embedding method. The frequency and quality factor of the resonant mode for the right-handed (left-handed) circularly polarized wave created by inserting a dielectric layer into the plasma increase (decrease) as the magnitude of the external magnetic field increases. These phenomena are compared with the characteristics of resonant modes in metallic and dielectric Fabry-Perot resonators to show that they are due to the change of plasma reflectivity. We also discuss the damping effect due to the collisions of the constituent particles of the plasma on the resonant transmission of circularly polarized waves. PMID:12689184

  7. Magnetic resonance enteroclysis: state of the art

    International Nuclear Information System (INIS)

    Full text: Magnetic Resonance Imaging (MRI) possess several virtues including superb soft-tissue contrast, absence of radiation exposure, cross-sectional and projectional imaging capabilities in all three dimensions and multiple contrast sources, that may favour a comprehensive morphologic and functional evaluation of the small bowel (SB). Ultrafast pulse sequences should be utilized to reduce motion related artifacts arising from physiological motion (respiration and peristalsis). the spatial resolution of these sequences should be high enough to permit demonstration of small lesions i.e. ulcers, that are usually present in small bowel diseases. MRI examination protocols of the small bowel usually comprise T1- and T2- weighted sequences on axial and coronal planes. Both T1- and T2- weighted sequences should be fast enough to allow comfortable breath-hold acquisition times and reduce the motion related artifacts. For T1- weighted images, most authors are using gradient echo sequences in 2D and 3D acquisition modes with or without fat saturation prepulses, while for T2-weighted images, TCE and HASTE sequences are commonly employed. True FISP sequence has been successfully applied in SB imaging, providing high resolution images of the bowel wall and additional information from the mesenteries. Fat suppressed TSE or STIR sequences have been also applied to access Crohn disease activity. True FISP sequence was introduced for MR examination of the small bowel after duodenal intubation. the contrast in true FISP images is somewhat more complex and invoke both T1 and T2 contributions in the form of the T2/T1 ratio. True FISP sequence is excellent in demonstrating the mesenteries, due to high contrast resolution between the bright peritoneal fat and the dark vessels and lymph nodes. Motion related artifacts are minimal on true FISP images due to short acquisition time. As opposed to HASTE sequences, true FISP is insensitive to intraluminal flow voids, due to its balanced

  8. Spin microscope based on optically detected magnetic resonance

    Science.gov (United States)

    Berman, Gennady P.; Chernobrod, Boris M.

    2007-12-11

    The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

  9. Quantum transport in coupled resonators enclosed synthetic magnetic flux

    Science.gov (United States)

    Jin, L.

    2016-07-01

    Quantum transport properties are instrumental to understanding quantum coherent transport processes. Potential applications of quantum transport are widespread, in areas ranging from quantum information science to quantum engineering, and not restricted to quantum state transfer, control and manipulation. Here, we study light transport in a ring array of coupled resonators enclosed synthetic magnetic flux. The ring configuration, with an arbitrary number of resonators embedded, forms a two-arm Aharonov-Bohm interferometer. The influence of magnetic flux on light transport is investigated. Tuning the magnetic flux can lead to resonant transmission, while half-integer magnetic flux quantum leads to completely destructive interference and transmission zeros in an interferometer with two equal arms.

  10. Magnetic Resonance Imaging and Magnetic Resonance Spectroscopy Characterize a Rodent Model of Covert Stroke

    Science.gov (United States)

    Herrera, Sheryl Lyn

    Covert stroke (CS) comprises lesions in the brain often associated by risk factors such as a diet high in fat, salt, cholesterol and sugar (HFSCS). Developing a rodent model for CS incorporating these characteristics is useful for developing and testing interventions. The purpose of this thesis was to determine if magnetic resonance (MR) can detect brain abnormalities to confirm this model will have the desired anatomical effects. Ex vivo MR showed brain abnormalities for rats with the induced lesions and fed the HFSCS diet. Spectra acquired on the fixed livers had an average percent area under the fat peak relative to the water peak of (20+/-4)% for HFSCS and (2+/-2)% for control. In vivo MR images had significant differences between surgeries to induce the lesions (p=0.04). These results show that applying MR identified abnormalities in the rat model and therefore is important in the development of this CS rodent model.

  11. Rotational characteristics in the resonance state of the HTSC-permanent magnet hybrid magnetic bearing

    International Nuclear Information System (INIS)

    The hybrid magnetic bearing has been developed. In the hybrid system, effect of the pinning force becomes smaller. Influence of the vibration and the gradient angle in the resonance state is large. The resonance frequency becomes small in the hybrid bearing system. The hybrid magnetic bearing using permanent magnets and the high-Tc bulk superconductor (HTSC) has been developed. Repulsive force of the permanent magnet is introduced to increase the load weight of the magnetic bearing. Effect of the hybrid system has been shown. In this paper, influence of the hybrid system on the dynamic characteristics of the rotor is studied. The rotational characteristics in the mechanical resonance state are studied, and the equivalent magnetic spring coefficient is estimated from the experimental results of the load weight. The resonance frequency is measured by the rotation experiments. The rotor achieves stable levitation even in the resonance state. In the hybrid system, effect of the pinning force becomes smaller than that of the lateral force generated by the repulsive force between the two permanent magnets at the smaller air gap. Thus influence of the lateral vibration and the gradient angle in the resonance state becomes larger at a smaller air gap. The equivalent magnetic spring coefficient becomes also small, and the resonance frequency becomes small in the hybrid bearing system.

  12. Rotational characteristics in the resonance state of the HTSC-permanent magnet hybrid magnetic bearing

    Energy Technology Data Exchange (ETDEWEB)

    Morii, Y.; Sukedai, M. [Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan); Ohashi, S., E-mail: ohashi@kansai-u.ac.jp [Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan)

    2011-11-15

    The hybrid magnetic bearing has been developed. In the hybrid system, effect of the pinning force becomes smaller. Influence of the vibration and the gradient angle in the resonance state is large. The resonance frequency becomes small in the hybrid bearing system. The hybrid magnetic bearing using permanent magnets and the high-Tc bulk superconductor (HTSC) has been developed. Repulsive force of the permanent magnet is introduced to increase the load weight of the magnetic bearing. Effect of the hybrid system has been shown. In this paper, influence of the hybrid system on the dynamic characteristics of the rotor is studied. The rotational characteristics in the mechanical resonance state are studied, and the equivalent magnetic spring coefficient is estimated from the experimental results of the load weight. The resonance frequency is measured by the rotation experiments. The rotor achieves stable levitation even in the resonance state. In the hybrid system, effect of the pinning force becomes smaller than that of the lateral force generated by the repulsive force between the two permanent magnets at the smaller air gap. Thus influence of the lateral vibration and the gradient angle in the resonance state becomes larger at a smaller air gap. The equivalent magnetic spring coefficient becomes also small, and the resonance frequency becomes small in the hybrid bearing system.

  13. Duffing oscillation-induced reversal of magnetic vortex core by a resonant perpendicular magnetic field

    OpenAIRE

    Kyoung-Woong Moon; Byong Sun Chun; Wondong Kim; Qiu, Z. Q.; Chanyong Hwang

    2014-01-01

    Nonlinear dynamics of the magnetic vortex state in a circular nanodisk was studied under a perpendicular alternating magnetic field that excites the radial modes of the magnetic resonance. Here, we show that as the oscillating frequency is swept down from a frequency higher than the eigenfrequency, the amplitude of the radial mode is almost doubled to the amplitude at the fixed resonance frequency. This amplitude has a hysteresis vs. frequency sweeping direction. Our result showed that this p...

  14. Dysembryoplastic neuroepithelial tumors: magnetic resonance imaging and magnetic resonance spectroscopy evaluation

    Institute of Scientific and Technical Information of China (English)

    YU Ai-hong; CHEN Li; LI Yong-jie; ZHANG Guo-jun; LI Kun-cheng; WANG Yu-ping

    2009-01-01

    Background Dysembryoplastic neuroepithelial tumor (DNT) is a rare benign neoplasm of the central nervous system affecting young people. A correct preoperative diagnosis is helpful for planning surgical strategies and improving prognosis. The purpose of this study was to characterize DNTs using magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) and to analyze the value of these two techniques in the diagnosis of DNTs.Methods MR images of 13 patients with DNTs were reviewed retrospectively; and five of the patients also underwent MRS. Tumors were confirmed by surgery. The distribution, extension and signal features of the lesions were assessed,and the MRS results were analyzed.Results All tumors were supratentorial. The cortex was the main area involved, with nine tumors located in the temporal lobe, three in the frontal lobe, and one on the boundary between the temporal and occipital lobes. All cases had decreased signal intensity on T1-weighted MR images and increased signal intensity on T2-weighted images. On fluid attenuated inversion recovery weighted images, the hyperintense "ring sign" and internal septation of the lesion were seen in 9 cases. Eight tumors had well-demarcated borders. Peritumoral edema or mass effect was absent in all cases. A contrast enhancement examination was performed in 9 cases. Contrast enhancement was absent in five cases, and four cases showed significant enhancement. The MRS showed a low N-acetylaspartate peak and a lack of elevated choline-containing component (Cho) or Cho-Cr ratio (Cho/Cr) in five patients.Conclusions The MRI findings of DNTs were stereotypical. The combination of MRI and MRS techniques were helpful in making a correct presurgical diagnosis.

  15. Chronic hepatosplenic schistosomiasis mansoni: magnetic resonance imaging and magnetic resonance angiography findings

    Energy Technology Data Exchange (ETDEWEB)

    Bezerra, A.S.; D' Ippolito, G.; Caldana, R.P.; Cecin, A.O.; Ahmed, M.; Szejnfeld, J. [Dept. of Diagnostic Imaging, Federal Univ. of Sao Paulo, Sao Paulo (Brazil)

    2007-02-15

    Purpose: To evaluate the hepatosplenic manifestations and the portal venous system in patients with chronic infection by Schistosoma mansoni. Material and Methods: A cross-sectional observational study was performed in 28 patients with chronic hepatosplenic schistosomiasis submitted to magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) of the abdomen. Images were interpreted independently by two radiologists to determine the reproducibility of image interpretation and who evaluated the presence of morphological alterations in the liver and spleen, such as hepatosplenomegaly, hepatic fissure widening, periportal fibrosis, and the presence of siderotic nodules. Interobserver and intra-observer agreement were measured with the kappa and intraclass correlation tests. Evaluation of venous collateral pathways and portal and splenic veins was done in consensus by both examiners. Results: Observers identified enlargement of the left lobe (78.5-92.8%) and caudate-to-right-lobe ratio (78.5-92.8%), irregularity of hepatic contours (89.2-96.4%), fissure widening (89.2-100%), and splenic siderotic nodules (84.2%). Splenomegaly, heterogeneity of hepatic parenchyma, peripheral hepatic vessels, and periportal fibrosis were observed in 100% of patients. MRI findings presented almost perfect interobserver (kappa 0.65-1) and intra-observer (kappa = 0.73-1 for observer 1, and kappa = 0.65-1 for observer 2) agreement for the variables analyzed. MRA showed the presence of collateral pathways in the majority of patients (71.4%) along with widening of portal and splenic veins. Conclusion: Using MRI, hepatosplenic alterations in schistosomiasis are characterized by heterogeneity of hepatic parenchyma, presence of peripheral perihepatic vessels, periportal fibrosis, splenomegaly, siderotic nodules, and the presence of venous collateral pathways.

  16. Comparison of nuclear electric resonance and nuclear magnetic resonance in integer and fractional quantum Hall states

    International Nuclear Information System (INIS)

    Electric-field-induced nuclear resonance (NER: nuclear electric resonance) involving quantum Hall states (QHSs) was studied at various filling factors by exploiting changes in nuclear spins polarized at quantum Hall breakdown. Distinct from the magnetic dipole interaction in nuclear magnetic resonance, the interaction of the electric-field gradient with the electric quadrupole moment plays the dominant role in the NER mechanism. The magnitude of the NER signal strongly depends on whether electronic states are localized or extended. This indicates that NER is sensitive to the screening capability of the electric field associated with QHSs

  17. Comparison of nuclear electric resonance and nuclear magnetic resonance in integer and fractional quantum Hall states

    Directory of Open Access Journals (Sweden)

    Toru Tomimatsu

    2015-08-01

    Full Text Available Electric-field-induced nuclear resonance (NER: nuclear electric resonance involving quantum Hall states (QHSs was studied at various filling factors by exploiting changes in nuclear spins polarized at quantum Hall breakdown. Distinct from the magnetic dipole interaction in nuclear magnetic resonance, the interaction of the electric-field gradient with the electric quadrupole moment plays the dominant role in the NER mechanism. The magnitude of the NER signal strongly depends on whether electronic states are localized or extended. This indicates that NER is sensitive to the screening capability of the electric field associated with QHSs.

  18. Early detection of spondyloarthropathy in patients with psoriasis by using the ultrasonography and magnetic resonance image

    Science.gov (United States)

    Hamdy, Maha; Omar, Gihan; Elshereef, Rawhya R; Ellaban, Abdou S; Amin, Mohamed

    2015-01-01

    Objective To assess the validity of ultrasound (US) in the early detection of arthritis and enthesitis, with assessment of the validity of magnetic resonance imaging (MRI) in the early detection of sacroiliitis and spondylitis in patients with psoriasis and to compare the findings of clinical examination and conventional radiography. Material and Methods The study included 50 patients with psoriasis and 20 healthy controls. All patients and controls underwent US and power Doppler analyses for the joints of both hands and feet and the entheseal sites. MRI of the lumbosacral spine and sacroiliac joints was performed. Results Abnormal US findings of arthritis were present in 18% patients, whereas only 6% patients had X-ray abnormalities, the enthesopathy represent 74%, at a higher percentage than clinical and radiological assessment (46, 26% respectively). MRI and radiological study demonstrated evidence of inflammation in the spine in 44% and 16% patients, respectively, and evidence of sacroiliitis in 10% and 6% patients, respectively. Conclusion Use of newer imaging modalities allows early diagnosis and early initiation of therapy.

  19. Three-dimensional magnetic recording using ferromagnetic resonance

    Science.gov (United States)

    Suto, Hirofumi; Kudo, Kiwamu; Nagasawa, Tazumi; Kanao, Taro; Mizushima, Koichi; Sato, Rie

    2016-07-01

    To meet the ever-increasing demand for data storage, future magnetic recording devices will need to be made three-dimensional by implementing multilayer recording. In this article, we present methods of detecting and manipulating the magnetization direction of a specific layer selectively in a vertically stacked multilayer magnetic system, which enable layer-selective read and write operations in three-dimensional magnetic recording devices. The principle behind the methods is ferromagnetic resonance excitation in a microwave magnetic field. By designing each magnetic recording layer to have a different ferromagnetic resonance frequency, magnetization excitation can be induced individually in each layer by tuning the frequency of an applied microwave magnetic field, and this selective magnetization excitation can be utilized for the layer-selective operations. Regarding media for three-dimensional recording, when layers of a perpendicular magnetic material are vertically stacked, dipolar interaction between multiple recording layers arises and is expected to cause problems, such as degradation of thermal stability and switching field distribution. To solve these problems, we propose the use of an antiferromagnetically coupled structure consisting of hard and soft magnetic layers. Because the stray fields from these two layers cancel each other, antiferromagnetically coupled media can reduce the dipolar interaction.

  20. Magnetic resonance imaging of the cervical and thoracic spine and the spinal cord

    International Nuclear Information System (INIS)

    Magnetic resonance imaging (MR), using a 0.3 T resistive scanner with an iron core and a vertical magnetic field, was evaluated in patients with different diseases affecting the cervical and thoracic spine and the spinal cord. The results indicate that MR is well suited as the procedure of choice for emergency examination of patients with spinal cord symptoms, for examination of patients with suspected spinal multiple sclerosis and for pre-operative evaluation of patients with rheumatoid arthritis with neurological symptoms emanating from the cranio-cervical junction. In patients with cervical radiculapathy and/or myelopathy, caused by spondylosis or disk herniation, MR was found to be equivalent with myelography and CT myelography but MR has several practical advantages. MR at 0.3 T using a vertical magnetic field provided information comparable to that reported from examinations performed with superconducting MR scanners. In order to optimize the MR examinations of the spine, the signal characteristics of different coils available when using a vertical magnetic field were determined by phantom studies. Recommendations for optimal coil selection for different levels of the cervical and thoracic spine are given. In addition, the paramagnetic contrast medium gadolinium-DTPA was administered intravenously to patients with suspected spinal multiple sclerosis. Enhancement of clinically active lesions in the cervical spinal cord was observed. Serial MR examinations with gadolinium-DTPA showed that a decrease in enhancement could be correlated with decrease in clinical symptoms and signs. (author)

  1. Magnetic resonance imaging features of hip disorders in an Egyptian pediatric population

    Directory of Open Access Journals (Sweden)

    Y. Ragab

    2015-09-01

    Full Text Available Hip disorders in a pediatric population are a diagnostic challenge. The aim of the study is to assess the role of magnetic resonance imaging (MRI in the evaluation of non-traumatic hip disorders in a series of Egyptian patients and to review the literature on the most common hip conditions. Seventy two consecutive patients [40 males (55.6% and 32 females (44.4] with acute onset of hip complaints unrelated to trauma or falls were recruited. All patients underwent an initial full clinical assessment and blood tests as well as contrast enhanced MRI of both hips. The most common diagnosis in this group of Egyptian patients was transient synovitis in 29 (40.3% cases, followed by seronegative enthesopathy and arthropathy syndrome in 8 (11.1%, septic arthritis in 10 (13.9%, tuberculous arthritis in 4 (5.6%, sickle-cell disease in 7 (9.7%, complicated with septic arthritis in 3 (4.2%, transient bone marrow edema (BME in 3 (4.2%, osteomyelitis in 2 (2.8%, osteosarcoma in 2 (2.8%, sciatic nerve injury in 1 (1.4%, leukemia with BME in 1 (1.4%, coxa vara of both hips and L5/S1 facet joint ankylosis in 1 (1.4%, and a benign bone cyst in 1 (1.4%. MRI studies showed hip effusion in a total of 51 patients (70.8%, joint space narrowing in 9 (12.5%, and BME in 15(20.8%. MRI is a sensitive tool for assessing hip disorders in a pediatric population and can play an important role in both diagnosis and management of different hip disorders, irrespective of the underlying pathology.

  2. Magnetic resonance imaging features of hip disorders in an Egyptian pediatric population.

    Science.gov (United States)

    Ragab, Y; Nabih, M; Aly, I; Kamal, A; Abd-Allah, M A; El-Refai, R; Emad, Y; El-Naggar, A; El-Shaarawy, N; Rasker, J J

    2015-01-01

    Hip disorders in a pediatric population are a diagnostic challenge. The aim of the study is to assess the role of magnetic resonance imaging (MRI) in the evaluation of non-traumatic hip disorders in a series of Egyptian patients and to review the literature on the most common hip conditions. Seventy two consecutive patients [40 males (55.6%) and 32 females (44.4)] with acute onset of hip complaints unrelated to trauma or falls were recruited. All patients underwent an initial full clinical assessment and blood tests as well as contrast enhanced MRI of both hips. The most common diagnosis in this group of Egyptian patients was transient synovitis in 29 (40.3%) cases, followed by seronegative enthesopathy and arthropathy syndrome in 8 (11.1%), septic arthritis in 10 (13.9%), tuberculous arthritis in 4 (5.6%), sickle-cell disease in 7 (9.7%), complicated with septic arthritis in 3 (4.2%), transient bone marrow edema (BME) in 3 (4.2%), osteomyelitis in 2 (2.8%), osteosarcoma in 2 (2.8%), sciatic nerve injury in 1 (1.4%), leukemia with BME in 1 (1.4%), coxa vara of both hips and L5/S1 facet joint ankylosis in 1 (1.4%), and a benign bone cyst in 1 (1.4%). MRI studies showed hip effusion in a total of 51 patients (70.8%), joint space narrowing in 9 (12.5%), and BME in 15(20.8%). MRI is a sensitive tool for assessing hip disorders in a pediatric population and can play an important role in both diagnosis and management of different hip disorders, irrespective of the underlying pathology. PMID:26492965

  3. Magnetic resonance imaging in the evaluation of periosteal reactions

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira-Barbosa, Marcello Henrique; Trad, Clovis Simao; Muglia, Valdair Francisco; Elias Junior, Jorge; Simao, Marcelo Novelino, E-mail: marcello@fmrp.usp.b [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Sa, Jose Luiz de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas; Oliveira, Rodrigo Cecilio Vieira de [Clinica de Diagnostico por Imagem Tomoson, Aracatuba, SP (Brazil); Engel, Edgard Eduard [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Dept. de Biomecanica, Medicina e Reabilitacao do Aparelho Locomotor

    2010-07-15

    The objective of the present essay was to encourage a careful evaluation of periosteal reactions on magnetic resonance images. The initial approach to bone lesions is made by conventional radiography and, based on the imaging findings, periosteal reactions are classified into classical subtypes. Although magnetic resonance imaging is considered as the gold standard for local staging of bone tumors, the utilization of such method in the study of periosteal reactions related to focal bone lesions has been poorly emphasized, with relatively few studies approaching this subject. The literature review revealed a study describing an experimental animal model of osteomyelitis suggesting that magnetic resonance imaging is superior to other imaging methods in the early identification of periosteal reactions. Another study has suggested a good correlation between conventional radiography and magnetic resonance imaging in the identification and classification of periosteal reactions in cases of osteosarcoma. The present essay illustrates cases of periosteal reactions observed at magnetic resonance imaging in correlation with findings of conventional radiography or other imaging methods. (author)

  4. Magnetic Resonance Imaging Studies of Postpartum Depression: An Overview

    Directory of Open Access Journals (Sweden)

    Marco Fiorelli

    2015-01-01

    Full Text Available Postpartum depression is a frequent and disabling condition whose pathophysiology is still unclear. In recent years, the study of the neural correlates of mental disorders has been increasingly approached using magnetic resonance techniques. In this review we synthesize the results from studies on postpartum depression in the context of structural, functional, and spectroscopic magnetic resonance studies of major depression as a whole. Compared to the relative wealth of data available for major depression, magnetic resonance studies of postpartum depression are limited in number and design. A systematic literature search yielded only eleven studies conducted on about one hundred mothers with postpartum depression overall. Brain magnetic resonance findings in postpartum depression appear to replicate those obtained in major depression, with minor deviations that are not sufficient to delineate a distinct neurobiological profile for this condition, due to the small samples used and the lack of direct comparisons with subjects with major depression. However, it seems reasonable to expect that studies conducted in larger populations, and using a larger variety of brain magnetic resonance techniques than has been done so far, might allow for the identification of neuroimaging signatures for postpartum depression.

  5. Resonance magnetic x-ray scattering study of erbium

    DEFF Research Database (Denmark)

    Sanyal, M.K.; Gibbs, D.; Bohr, J.;

    1994-01-01

    of this magnetic scattering and analyzed it using a simple model based on electric dipole and quadrupole transitions among atomic orbitals. The line shapes can be fitted to a magnetic structure combining both c-axis-modulated and basal-plane components. Below 18 K, we have observed unusual behavior......The magnetic phases of erbium have been studied by resonance x-ray-scattering techniques. When the incident x-ray energy is tuned near the L(III) absorption edge, large resonant enhancements of the magnetic scattering are observed above 18 K. We have measured the energy and polarization dependence...... of the magnetic scattering as a function of energy, whose origin is not understood....

  6. Introduction to magnetic resonance and its application to dipole magnet testing

    International Nuclear Information System (INIS)

    An introduction to the features of magnetic resonance that are essential for understanding its application to testing accelerator dipole magnets is presented, including the accuracy that can be expected in field measurements and the factors that limit it. The use of an array of coils to measure the multipole moments of dipole magnets is discussed

  7. Current-induced spin torque resonance of a magnetic insulator

    Science.gov (United States)

    Schreier, Michael; Chiba, Takahiro; Niedermayr, Arthur; Lotze, Johannes; Huebl, Hans; Geprägs, Stephan; Takahashi, Saburo; Bauer, Gerrit E. W.; Gross, Rudolf; Goennenwein, Sebastian T. B.

    2015-10-01

    We report the observation of current-induced spin torque resonance in yttrium iron garnet/platinum bilayers. An alternating charge current at GHz frequencies in the platinum gives rise to dc spin pumping and spin Hall magnetoresistance rectification voltages, induced by the Oersted fields of the ac current and the spin Hall effect-mediated spin transfer torque. In ultrathin yttrium iron garnet films, we observe spin transfer torque actuated magnetization dynamics which are significantly larger than those generated by the ac Oersted field. Spin transfer torques thus efficiently couple charge currents and magnetization dynamics also in magnetic insulators, enabling charge current-based interfacing of magnetic insulators with microwave devices.

  8. Resonant Landau–Zener transitions in a helical magnetic field

    International Nuclear Information System (INIS)

    Spin-dependent electron transport has been studied in magnetic semiconductor waveguides (nanowires) in the helical magnetic field. We have shown that—apart from the well-known conductance dip located at the magnetic field equal to the helical-field amplitude Bh—the additional conductance dips (with zero conductance) appear at a magnetic field different from Bh. This effect occurring in the non-adiabatic regime is explained as resulting from the resonant Landau–Zener transitions between the spin-split subbands. (paper)

  9. Magnetic anisotropy of polycrystalline magnetoferritin investigated by SQUID and electron magnetic resonance

    Science.gov (United States)

    Moro, F.; de Miguel, R.; Jenkins, M.; Gómez-Moreno, C.; Sells, D.; Tuna, F.; McInnes, E. J. L.; Lostao, A.; Luis, F.; van Slageren, J.

    2014-06-01

    Magnetoferritin molecules with an average inorganic core diameter of 5.7±1.6 nm and polycrystalline internal structure were investigated by a combination of transmission electron microscopy, magnetic susceptibility, magnetization, and electron magnetic resonance (EMR) experiments. The temperature and frequency dependence of the magnetic susceptibility allowed for the determination of the magnetic anisotropy on an experimental time scale which spans from seconds to nanoseconds. In addition, angle-dependent EMR experiments were carried out for the determination of the nanoparticle symmetry and internal magnetic field. Due to the large surface to volume ratio, the nanoparticles show larger and uniaxial rather than cubic magnetic anisotropies compared to bulk maghemite and magnetite.

  10. On-wafer magnetic resonance of magnetite nanoparticles

    Science.gov (United States)

    Little, Charles A. E.; Russek, Stephen E.; Booth, James C.; Kabos, Pavel; Usselman, Robert J.

    2015-11-01

    Magnetic resonance measurements of ferumoxytol and TEMPO were made using an on-wafer transmission line technique with a vector network analyzer, allowing for broadband measurements of small sample volumes (4 nL) and small numbers of spins (1 nmol). On-wafer resonance measurements were compared with standard single-frequency cavity-based electron paramagnetic resonance (EPR) measurements using a new power conservation approach and the results show similar line shape. On-wafer magnetic resonance measurements using integrated microfluidics and microwave technology can significantly reduce the cost and sample volumes required for EPR spectral analysis and allow for integration of EPR with existing lab-on-a-chip processing and characterization techniques for point-of-care medical diagnostic applications.

  11. On-wafer magnetic resonance of magnetite nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Little, Charles A.E., E-mail: caelittle@gmail.com; Russek, Stephen E., E-mail: stephen.russek@nist.gov; Booth, James C., E-mail: james.booth@nist.gov; Kabos, Pavel, E-mail: pavel.kabos@nist.gov; Usselman, Robert J., E-mail: robertusselman@gmail.com

    2015-11-01

    Magnetic resonance measurements of ferumoxytol and TEMPO were made using an on-wafer transmission line technique with a vector network analyzer, allowing for broadband measurements of small sample volumes (4 nL) and small numbers of spins (1 nmol). On-wafer resonance measurements were compared with standard single-frequency cavity-based electron paramagnetic resonance (EPR) measurements using a new power conservation approach and the results show similar line shape. On-wafer magnetic resonance measurements using integrated microfluidics and microwave technology can significantly reduce the cost and sample volumes required for EPR spectral analysis and allow for integration of EPR with existing lab-on-a-chip processing and characterization techniques for point-of-care medical diagnostic applications. - Highlights: • On-wafer measurements showed similar line shape to traditional cavity-based EPR. • New power conservation approach alleviates de-embedding ambiguities. • Allows for measurements of small sample volumes and small number of spins.

  12. Magnetic Barkhausen noise measurement by resonant coil method

    Energy Technology Data Exchange (ETDEWEB)

    Capo-Sanchez, J. [Departamento de Fisica, Facultad de Ciencias Naturales, Universidad de Oriente, Av. Patricio Lumumba s/n, 90500 Santiago de Cuba (Cuba)], E-mail: jcapo@usp.br; Padovese, L. [Departamento de Engenharia Mecanica, Escola Politecnica, Universidade de Sao Paulo, Av. Prof. Mello Moraes, 2231, 05508-900 Sao Paulo (Brazil)

    2009-09-15

    This paper describes a powerful new technique for nondestructive evaluation of ferromagnetic material. A method has been developed for measuring magnetic Barkhausen signals under different coil resonance frequencies. The measurements allow one to establish the behavior relating the power spectral density maximum and the resonant coil frequency. Time-frequency analysis of Barkhausen signals puts in evidence the tuning regions for each coil, and allows clear identification of each contribution to the Barkhausen signal spectrum. This concept was used in order to evaluate the relation between the degree of plastic deformation in carbon steel samples, and the power spectral density maximum at different resonance frequencies. This result also makes it possible to the selectively modify measurement sensibility to the magnetic Barkhausen signal by using different resonance frequencies.

  13. Magnetic hysteresis effects in superconducting coplanar microwave resonators

    Energy Technology Data Exchange (ETDEWEB)

    Bothner, D.; Gaber, T.; Kemmler, M.; Gruenzweig, M.; Ferdinand, B.; Koelle, D.; Kleiner, R. [Universitaet Tuebingen (Germany); Wuensch, S.; Siegel, M. [Karlsruher Institut fuer Technologie (Germany); Mikheenko, P.; Johansen, T.H. [University of Oslo (Norway)

    2013-07-01

    We present experimental data regarding the impact of external magnetic fields on quality factor and resonance frequency of superconducting microwave resonators in a coplanar waveguide geometry. In particular we focus on the influence of magnetic history and show with the assistance of numerical calculations that the found hysteretic behaviour can be well understood with a highly inhomogeneous microwave current density in combination with established field penetration models for type-II superconducting thin films. Furthermore we have used magneto-optical imaging techniques to check the field distribution which we have assumed in our calculations. Finally, we demonstrate that and how the observed hysteretic behaviour can be used to optimize and tune the resonator performance for possible hybrid quantum sytems in magnetic fields.

  14. Imaging using long range dipolar field effects Nuclear magnetic resonance

    CERN Document Server

    Gutteridge, S

    2002-01-01

    The work in this thesis has been undertaken by the except where indicated in reference, within the Magnetic Resonance Centre, at the University of Nottingham during the period from October 1998 to March 2001. This thesis details the different characteristics of the long range dipolar field and its application to magnetic resonance imaging. The long range dipolar field is usually neglected in nuclear magnetic resonance experiments, as molecular tumbling decouples its effect at short distances. However, in highly polarised samples residual long range components have a significant effect on the evolution of the magnetisation, giving rise to multiple spin echoes and unexpected quantum coherences. Three applications utilising these dipolar field effects are documented in this thesis. The first demonstrates the spatial sensitivity of the signal generated via dipolar field effects in structured liquid state samples. The second utilises the signal produced by the dipolar field to create proton spin density maps. Thes...

  15. Clinical software VIII for magnetic resonance imaging systems

    Energy Technology Data Exchange (ETDEWEB)

    Kohno, Satoru; Takeo, Kazuhiro [Medical Applications Department, Medical Systems Division, Shimadzu Corporation, Kyoto (Japan)

    2001-02-01

    This report describes the latest techniques of MRA (magnetic resonance angiography) and the brain attack diagnosis protocol which are now effectively utilized in the Shimadzu-Marconi MAGNEX ECLIPSE MRI (magnetic resonance imaging) system (1.5 tesla type) and the MAGNEX POLARIS MRI system (1.0 tesla type). As for the latest techniques for MRA, this report refers to the SLINKY (sliding interleaved ky) technique, which provides high-resolution images over a wide range in the direction of slice, without using contrast agent, and to the iPass technique which enables highly reliable CE-MRA (contrast-enhanced magnetic resonance angiography), through easy and simple operation. Also reported are the techniques of diffusion imaging and perfusion imaging, utilized for stroke assessment. (author)

  16. Magnetic resonance spectroscopy and imaging for the study of fossils.

    Science.gov (United States)

    Giovannetti, Giulio; Guerrini, Andrea; Salvadori, Piero A

    2016-07-01

    Computed tomography (CT) has long been used for investigating palaeontological specimens, as it is a nondestructive technique which avoids the need to dissolve or ionize the fossil sample. However, magnetic resonance spectroscopy (MRS) and magnetic resonance imaging (MRI) have recently gained ground as analytical tools for examination of palaeontological samples, by nondestructively providing information about the structure and composition of fossils. While MRI techniques are able to reveal the three-dimensional geometry of the trace fossil, MRS can provide information on the chemical composition of the samples. The multidimensional nature of MR (magnetic resonance) signals has potential to provide rich three-dimensional data on the palaeontological specimens and also to help in elucidating paleopathological and paleoecological questions. In this work the verified applications and the emerging uses of MRI and MRS in paleontology are reviewed, with particular attention to fossil spores, fossil plants, ambers, fossil invertebrates, and fossil vertebrate studies. PMID:26979538

  17. Septic arthritis of the knee associated with calf abscess.

    Science.gov (United States)

    Izumi, Masashi; Ikeuchi, Masahiko; Tani, Toshikazu

    2012-08-01

    Septic arthritis associated with extra-articular abscess is rare. We report on 2 non-rheumatic patients with septic arthritis of the knee associated with calf abscess. Magnetic resonance imaging showed a distinct leakage pathway from the knee joint in each patient. One was a ruptured popliteal cyst (posteromedial). Another was a pathologic popliteus hiatus (posterolateral). These patients underwent open drainage of the calf abscess via a small incision, followed by arthroscopic debridement of the knee. Careful palpation of the lower leg, followed by magnetic resonance imaging and needle aspiration, is important to exclude a possible extra-articular abscess regardless of the presence of a popliteal cyst.

  18. Biological effects of exposure to magnetic resonance imaging: an overview

    Directory of Open Access Journals (Sweden)

    Formica Domenico

    2004-04-01

    Full Text Available Abstract The literature on biological effects of magnetic and electromagnetic fields commonly utilized in magnetic resonance imaging systems is surveyed here. After an introduction on the basic principles of magnetic resonance imaging and the electric and magnetic properties of biological tissues, the basic phenomena to understand the bio-effects are described in classical terms. Values of field strengths and frequencies commonly utilized in these diagnostic systems are reported in order to allow the integration of the specific literature on the bio-effects produced by magnetic resonance systems with the vast literature concerning the bio-effects produced by electromagnetic fields. This work gives an overview of the findings about the safety concerns of exposure to static magnetic fields, radio-frequency fields, and time varying magnetic field gradients, focusing primarily on the physics of the interactions between these electromagnetic fields and biological matter. The scientific literature is summarized, integrated, and critically analyzed with the help of authoritative reviews by recognized experts, international safety guidelines are also cited.

  19. Simulation of Magnetic Resonance for Wireless Power Transfer

    Directory of Open Access Journals (Sweden)

    Liang Zhao

    2013-02-01

    Full Text Available André Kurs et al. et al. (2007 in Science 317, 83 titled Wireless Power Transfer via Strongly Coupled Magnetic Resonances, proposed a feasible scheme to near-field transfer electric energy. Here in this report we take note of our simulation on COMSOL 4.1.085 to repeat his counterpart in Chapter 4 of his master thesis. Due to huge requirement on memory size, my simulation fails to align with Kurs', but basic steps and setup instructions are given. Very importantly, every scholar with electromagnetic background would simply take this as magnetic inducing current in closed loops, exactly as we did. Yet, this imparts more essence on resonance. A look into coupled-mode theory will find this takes advantage of near-field magnetic field to transfer energy. A transformer, a true product of magnetic induction, if simply detached by a distance would greatly reduce its transfer efficiency, whereas magnetic resonance DOES NOT! So this is more than only magnetic induction. Although coupled-mode theory is still not physical enough to illustrate readers, neither does magnetic induction in Maxwell's equations give its simple picture! Coupled-mode theory perhaps is a simple way out quantitatively and mathematically.

  20. Malformations of cortical development:3T magnetic resonance imaging features

    Institute of Scientific and Technical Information of China (English)

    Bilal; Battal; Selami; Ince; Veysel; Akgun; Murat; Kocaoglu; Emrah; Ozcan; Mustafa; Tasar

    2015-01-01

    Malformation of cortical development(MCD) is a term representing an inhomogeneous group of central nervous system abnormalities, referring particularly to embriyological aspect as a consequence of any of the three developmental stages, i.e., cell proliferation, cell migration and cortical organization. These include cotical dysgenesis, microcephaly, polymicrogyria, schizencephaly, lissencephaly, hemimegalencephaly, heterotopia and focal cortical dysplasia. Since magnetic resonance imaging is the modality of choice that best identifies the structural anomalies of the brain cortex, we aimed to provide a mini review of MCD by using 3T magnetic resonance scanner images.