WorldWideScience

Sample records for artery stenting trial

  1. Low-profile stent system for treatment of atherosclerotic renal artery stenosis : The GREAT trial

    NARCIS (Netherlands)

    Sapoval, Marc; Zahringer, Markus; Pattynama, Peter; Rabbia, Claudio; Vignali, Claudio; Maleux, Geert; Boyer, Louis; Szczerbo-Trojanowska, Malgorzata; Jaschke, Werner; Hafsahl, Geir; Downes, Mark; Beregi, Jean Paul; Veeger, Nic; Talen, Aly

    PURPOSE: The Palmaz Genesis Peripheral Stainless Steel Balloon Expandable Stent in Renal Artery Treatment (GREAT) Trial was designed to assess the safety and performance of a low-profile stent for the treatment of obstructive renal artery disease by looking at 6-month renal artery patency uniformly

  2. Study design and rationale of the 'Balloon-Expandable Cobalt Chromium SCUBA Stent versus Self-Expandable COMPLETE-SE Nitinol Stent for the Atherosclerotic ILIAC Arterial Disease (SENS-ILIAC Trial) Trial': study protocol for a randomized controlled trial.

    Science.gov (United States)

    Choi, Woong Gil; Rha, Seung Woon; Choi, Cheol Ung; Kim, Eung Ju; Oh, Dong Joo; Cho, Yoon Hyung; Park, Sang Ho; Lee, Seung Jin; Hur, Ae Yong; Ko, Young Guk; Park, Sang Min; Kim, Ki Chang; Kim, Joo Han; Kim, Min Woong; Kim, Sang Min; Bae, Jang Ho; Bong, Jung Min; Kang, Won Yu; Seo, Jae Bin; Jung, Woo Yong; Cho, Jang Hyun; Kim, Do Hoi; Ahn, Ji Hoon; Kim, Soo Hyun; Jang, Ji Yong

    2016-06-25

    The self-expandable COMPLETE™ stent (Medtronic) has greater elasticity, allowing it to regain its shape after the compression force reduces, and has higher trackability, thus is easier to maneuver through tortuous vessels, whereas the balloon-expandable SCUBA™ stent (Medtronic) has higher radial stiffness and can afford more accurate placement without geographic miss, which is important in aortoiliac bifurcation lesions. To date, there have been no randomized control trials comparing efficacy and safety between the self-expanding stent and balloon-expandable stent in advanced atherosclerotic iliac artery disease. The purpose of our study is to examine primary patency (efficacy) and incidence of stent fracture and geographic miss (safety) between two different major representative stents, the self-expanding nitinol stent (COMPLETE-SE™) and the balloon-expanding cobalt-chromium stent (SCUBA™), in stenotic or occlusive iliac arterial lesions. This trial is designed as a prospective, randomized, multicenter trial to demonstrate a noninferiority of SCUBA™ stent to COMPLETE-SE™ stent following balloon angioplasty in iliac arterial lesions, and a total of 280 patients will be enrolled. The primary end point of this study is the rate of primary patency in the treated segment at 12 months after intervention as determined by catheter angiography, computed tomography angiography, or duplex ultrasound. The SENS-ILIAC trial will give powerful insight into whether the stent choice according to deployment mechanics would impact stent patency, geographic miss, or stent fracture in patients undergoing stent implantation in iliac artery lesions. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier: NCT01834495 ), registration date: May 8, 2012.

  3. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  4. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2010-03-20

    Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy.

  5. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial.

    NARCIS (Netherlands)

    Ederle, J.; Dobson, J.; Featherstone, R.L.; Bonati, L.H.; Worp, H.B. van der; Borst, G.J. de; Lo, T.H.; Gaines, P.; Dorman, P.J.; Macdonald, S.; Lyrer, P.A.; Hendriks, J.M.; McCollum, C.; Nederkoorn, P.J.; Brown, M.M.; Blankensteijn, J.D.; Leeuw, F.E. de; Schultze Kool, L.J.; Vliet, J.A. van der; et al.,

    2010-01-01

    BACKGROUND: Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. METHODS: The International

  6. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial

    NARCIS (Netherlands)

    Ederle, Jörg; Dobson, Joanna; Featherstone, Roland L.; Bonati, Leo H.; van der Worp, H. Bart; de Borst, Gert J.; Lo, T. Hauw; Gaines, Peter; Dorman, Paul J.; Macdonald, Sumaira; Lyrer, Philippe A.; Hendriks, Johanna M.; McCollum, Charles; Nederkoorn, Paul J.; Brown, Martin M.; Algra, A.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Clifton, A.; Gaines, P.; Collins, R.; Molyneux, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Bonati, L. H.; Coward, L.; Dobson, J.; Ederle, J.; Featherstone, R. F.; Tindall, H.; McCabe, D. J. H.; Wallis, A.; Brooks, M.; Chambers, B.; Chan, A.; Chu, P.; Clark, D.; Dewey, H.; Donnan, G.; Fell, G.; Hoare, M.; Molan, M.; Roberts, A.; Roberts, N.; Beiles, B.; Bladin, C.; Clifford, C.; Grigg, M.; New, G.; Bell, R.; Bower, S.; Chong, W.; Holt, M.; Saunder, A.; Than, P. G.; Gett, S.; Leggett, D.; McGahan, T.; Quinn, J.; Ray, M.; Wong, A.; Woodruff, P.; Foreman, R.; Schultz, D.; Scroop, R.; Stanley, B.; Allard, B.; Atkinson, N.; Cambell, W.; Davies, S.; Field, P.; Milne, P.; Mitchell, P.; Tress, B.; Yan, B.; Beasley, A.; Dunbabin, D.; Stary, D.; Walker, S.; Cras, P.; d'Archambeau, O.; Hendriks, J. M. H.; van Schil, P.; St Blasius, A. Z.; Bosiers, M.; Deloose, K.; van Buggenhout, E.; de Letter, J.; Devos, V.; Ghekiere, J.; Vanhooren, G.; Astarci, P.; Hammer, F.; Lacroix, V.; Peeters, A.; Verbist, J.; Blair, J.-F.; Caron, J. L.; Daneault, N.; Giroux, M.-F.; Guilbert, F.; Lanthier, S.; Lebrun, L.-H.; Oliva, V.; Raymond, J.; Roy, D.; Soulez, G.; Weill, A.; Hill, M.; Hu, W.; Hudion, M.; Morrish, W.; Sutherland, G.; Wong, J.; Albäck, A.; Harno, H.; Ijäs, P.; Kaste, M.; Lepäntalo, M.; Mustanoja, S.; Paananen, T.; Porras, M.; Putaala, J.; Railo, M.; Sairanen, T.; Soinne, L.; Vehmas, A.; Vikatmaa, P.; Goertler, M.; Halloul, Z.; Skalej, M.; Brennan, P.; Kelly, C.; Leahy, A.; Moroney, J.; Thornton, J.; Koelemay, M. J. W.; Reekers, J. A. A.; Roos, Y. B. W. E. M.; Hendriks, J. M.; Koudstaal, P. J.; Pattynama, P. M. T.; van der Lugt, A.; van Dijk, L. C.; van Sambeek, M. R. H. M.; van Urk, H.; Verhagen, H. J. M.; Bruijninckx, C. M. A.; de Bruijn, S. F.; Keunen, R.; Knippenberg, B.; Mosch, A.; Treurniet, F.; van Dijk, L.; van Overhagen, H.; Wever, J.; de Beer, F. C.; van den Berg, J. S. P.; van Hasselt, B. A. A. M.; Zeilstra, D. J.; Boiten, J.; van Otterloo, J. C. A. de Mol; de Vries, A. C.; Lycklama a Nijeholt, G. J.; van der Kallen, B. F. W.; Blankensteijn, J. D.; de Leeuw, F. E.; Kool, L. J. Schultze; van der Vliet, J. A.; de Borst, G. J.; de Kort, G. A. P.; Kapelle, L. J.; Lo, T. H.; Mali, W. P. Th M.; Moll, F.; van der Worp, H. B.; Verhagen, H.; Barber, P. A.; Bourchier, R.; Hill, A.; Holden, A.; Stewart, J.; Bakke, S. J.; Krohg-Sørensen, K.; Skjelland, M.; Tennøe, B.; Bialek, P.; Biejat, Z.; Czepiel, W.; Czlonkowska, A.; Dowzenko, A.; Jedrzejewska, J.; Kobayashi, A.; Lelek, M.; Polanski, J.; Kirbis, J.; Milosevic, Z.; Zvan, B.; Blasco, J.; Chamorro, A.; Macho, J.; Obach, V.; Riambau, V.; San Roman, L.; Branera, J.; Canovas, D.; Estela, Jordi; Gaibar, A. Gimenez; Perendreu, J.; Björses, K.; Gottsater, A.; Ivancev, K.; Maetzsch, T.; Sonesson, B.; Berg, B.; Delle, M.; Formgren, J.; Gillgren, P.; Kall, T.-B.; Konrad, P.; Nyman, N.; Takolander, R.; Andersson, T.; Malmstedt, J.; Soderman, M.; Wahlgren, C.; Wahlgren, N.; Binaghi, S.; Hirt, L.; Michel, P.; Ruchat, P.; Engelter, S. T.; Fluri, F.; Guerke, L.; Jacob, A. L.; Kirsch, E.; Lyrer, P. A.; Radue, E.-W.; Stierli, P.; Wasner, M.; Wetzel, S.; Bonvin, C.; Kalangos, A.; Lovblad, K.; Murith, M.; Ruefenacht, D.; Sztajzel, R.; Higgins, N.; Kirkpatrick, P. J.; Martin, P.; Varty, K.; Adam, D.; Bell, J.; Crowe, P.; Gannon, M.; Henderson, M. J.; Sandler, D.; Shinton, R. A.; Scriven, J. M.; Wilmink, T.; D'Souza, S.; Egun, A.; Guta, R.; Punekar, S.; Seriki, D. M.; Thomson, G.; Brennan, J. A.; Enevoldson, T. P.; Gilling-Smith, G.; Gould, D. A.; Harris, P. L.; McWilliams, R. G.; Nasser, H.-C.; White, R.; Prakash, K. G.; Serracino-Inglott, F.; Subramanian, G.; Symth, J. V.; Walker, M. G.; Clarke, M.; Davis, M.; Dixit, S. A.; Dorman, P.; Dyker, A.; Ford, G.; Golkar, A.; Jackson, R.; Jayakrishnan, V.; Lambert, D.; Lees, T.; Louw, S.; Macdonald, S.; Mendelow, A. D.; Rodgers, H.; Rose, J.; Stansby, G.; Wyatt, M.; Baker, T.; Baldwin, N.; Jones, L.; Mitchell, D.; Munro, E.; Thornton, M.; Baker, D.; Davis, N.; Hamilton, G.; McCabe, D.; Platts, A.; Tibballs, J.; Cleveland, T.; Dodd, D.; Lonsdale, R.; Nair, R.; Nassef, A.; Nawaz, S.; Venables, G.; Belli, A.; Cloud, G.; Halliday, A.; Markus, H.; McFarland, R.; Morgan, R.; Pereira, A.; Thompson, A.; Chataway, J.; Cheshire, N.; Gibbs, R.; Hammady, M.; Jenkins, M.; Malik, I.; Wolfe, J.; Adiseshiah, M.; Bishop, C.; Brew, S.; Brookes, J.; Jäger, R.; Kitchen, N.; Ashleigh, R.; Butterfield, S.; Gamble, G. E.; McCollum, C.; Nasim, A.; O'Neill, P.; Edwards, R. D.; Lees, K. R.; MacKay, A. J.; Moss, J.

    2010-01-01

    BACKGROUND: Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. METHODS: The International

  7. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study) : an interim analysis of a randomised controlled trial

    NARCIS (Netherlands)

    Ederle, Joerg; Dobson, Joanna; Featherstone, Roland L.; Bonati, Leo H.; van der Worp, H. Bart; de Borst, Gert J.; Lo, T. Hauw; Gaines, Peter; Dorman, Paul J.; Macdonald, Sumaira; Lyrer, Philippe A.; Hendriks, Johanna M.; McCollum, Charles; Nederkoorn, Paul J.; Brown, Martin M.; Algra, A.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Clifton, A.; Gaines, P.; Hacke, W.; Halliday, A.; Malik, I.; Mas, J. L.; McGuire, A. J.; Sidhu, P.; Venables, G.; Bradbury, A.; Brown, M. M.; Clifton, A.; Gaines, P.; Collins, R.; Molynewc, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Bonati, L. H.; Coward, L.; Dobson, J.; Ederle, J.; Featherstone, R. F.; Tindall, H.; McCabe, D. J. H.; Wallis, A.; Hendriks, J. M. H.; Hendriks, J. M.

    2010-01-01

    Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid

  8. Restenosis after carotid artery stenting and endarterectomy: a secondary analysis of CREST, a randomised controlled trial.

    Science.gov (United States)

    Lal, Brajesh K; Beach, Kirk W; Roubin, Gary S; Lutsep, Helmi L; Moore, Wesley S; Malas, Mahmoud B; Chiu, David; Gonzales, Nicole R; Burke, J Lee; Rinaldi, Michael; Elmore, James R; Weaver, Fred A; Narins, Craig R; Foster, Malcolm; Hodgson, Kim J; Shepard, Alexander D; Meschia, James F; Bergelin, Robert O; Voeks, Jenifer H; Howard, George; Brott, Thomas G

    2012-09-01

    In the Carotid Revascularization Endarterectomy versus Stenting Trial (CREST), the composite primary endpoint of stroke, myocardial infarction, or death during the periprocedural period or ipsilateral stroke thereafter did not differ between carotid artery stenting and carotid endarterectomy for symptomatic or asymptomatic carotid stenosis. A secondary aim of this randomised trial was to compare the composite endpoint of restenosis or occlusion. Patients with stenosis of the carotid artery who were asymptomatic or had had a transient ischaemic attack, amaurosis fugax, or a minor stroke were eligible for CREST and were enrolled at 117 clinical centres in the USA and Canada between Dec 21, 2000, and July 18, 2008. In this secondary analysis, the main endpoint was a composite of restenosis or occlusion at 2 years. Restenosis and occlusion were assessed by duplex ultrasonography at 1, 6, 12, 24, and 48 months and were defined as a reduction in diameter of the target artery of at least 70%, diagnosed by a peak systolic velocity of at least 3·0 m/s. Studies were done in CREST-certified laboratories and interpreted at the Ultrasound Core Laboratory (University of Washington). The frequency of restenosis was calculated by Kaplan-Meier survival estimates and was compared during a 2-year follow-up period. We used proportional hazards models to assess the association between baseline characteristics and risk of restenosis. Analyses were per protocol. CREST is registered with ClinicalTrials.gov, number NCT00004732. 2191 patients received their assigned treatment within 30 days of randomisation and had eligible ultrasonography (1086 who had carotid artery stenting, 1105 who had carotid endarterectomy). In 2 years, 58 patients who underwent carotid artery stenting (Kaplan-Meier rate 6·0%) and 62 who had carotid endarterectomy (6·3%) had restenosis or occlusion (hazard ratio [HR] 0·90, 95% CI 0·63-1·29; p=0·58). Female sex (1·79, 1·25-2·56), diabetes (2·31, 1·61-3·31

  9. Effect of white-matter lesions on the risk of periprocedural stroke after carotid artery stenting versus endarterectomy in the International Carotid Stenting Study (ICSS): a prespecified analysis of data from a randomised trial

    NARCIS (Netherlands)

    Ederle, J.; Davagnanam, I.; Worp, H.B. van der; Venables, G.S.; Lyrer, P.A.; Featherstone, R.L.; Brown, M.M.; Jager, H.R.; Leeuw, F.E. de; Schultze Kool, L.J.; Vliet, J.A. van der; et al.,

    2013-01-01

    BACKGROUND: Findings from randomised trials have shown a higher early risk of stroke after carotid artery stenting than after carotid endarterectomy. We assessed whether white-matter lesions affect the perioperative risk of stroke in patients treated with carotid artery stenting versus carotid

  10. Off-pump coronary artery bypass grafting or percutaneous transluminal coronary angioplasty with stenting for proximal left anterior descending coronary artery disease?

    NARCIS (Netherlands)

    Drenth, Derk Jan

    2005-01-01

    This thesis describes and discusses the results of a prospective randomized controlled clinical trial comparing percutaneous coronary angioplasty with stenting (stenting) and off-pump coronary artery bypass grafting with a left internal mammary artery (surgery) in patients with a high-grade stenosis

  11. A randomized, controlled, multicenter trial to evaluate the safety and efficacy of Zotarolimus- vs. Paclitaxel-eluting stents in de novo occlusive lesions in coronary arteries

    DEFF Research Database (Denmark)

    Chevalier, Bernard; Dimario, Carlo; Neumann, Franz-Josef

    2013-01-01

    The ZOMAXX I trial tested the noninferiority of a zotarolimus-eluting coronary stent (ZoMaxx(™) ) when compared with a paclitaxel-eluting coronary stent (Taxus(™) Express(2™) ) in a randomized trial of percutaneous intervention for de novo coronary artery stenosis. Angiographic analysis at the pr...

  12. Carotid artery stenting in high surgical risk patients using the FiberNet embolic protection system: the EPIC trial results.

    Science.gov (United States)

    Myla, Subbarao; Bacharach, J Michael; Ansel, Gary M; Dippel, Eric J; McCormick, Daniel J; Popma, Jeffrey J

    2010-05-01

    The multicenter EPIC (FiberNet Embolic Protection System in Carotid Artery Stenting Trial) single-arm trial evaluated the 30-day outcomes of a new design concept for embolic protection during carotid artery stenting (CAS). Embolic protection filters available for use during CAS include fixed and over-the-wire systems that rely on embolic material capture within a "basket" structure. The FiberNet Embolic Protection System (EPS), which features a very low crossing profile, consists of a three-dimensional fiber-based filter distally mounted on a 0.014 inch guidewire with integrated aspiration during filter retrieval. The trial enrolled 237 patients from 26 centers. Demographics, clinical and lesion characteristics, as well as adverse events through a 30-day follow-up were recorded. The mean age of the patients was 74 years, 64% were male and 20% had symptomatic carotid artery disease. The combined major adverse event (MAE) rate at 30 days for all death, stroke, and myocardial infarction was 3.0%. There were three major strokes (two ischemic and one hemorrhagic) and two minor strokes (both ischemic) for a 2.1% 30-day stroke rate. The procedural technical success rate was 97.5% and macroscopic evidence of debris was reported in 90.9% of the procedures. The FiberNet EPS, used with commercially available stents, produced low stroke rates following CAS in high surgical risk patients presenting with carotid artery disease. The unique filter design including aspiration during retrieval may have contributed to the low 30-day stroke rate reported during CAS in patients considered at high risk for complications following carotid endarterectomy (CEA). Copyright 2010 Wiley-Liss, Inc.

  13. Renal Artery Stenosis in Patients with Resistant Hypertension: Stent It or Not?

    Science.gov (United States)

    Van der Niepen, Patricia; Rossignol, Patrick; Lengelé, Jean-Philippe; Berra, Elena; Sarafidis, Pantelis; Persu, Alexandre

    2017-01-01

    After three large neutral trials in which renal artery revascularization failed to reduce cardiovascular and renal morbidity and mortality, renal artery stenting became a therapeutic taboo. However, this is probably unjustified as these trials have important limitations and excluded patients most likely to benefit from revascularization. In particular, patients with severe hypertension were often excluded and resistant hypertension was either poorly described or not conform to the current definition. Effective pharmacological combination treatment can control blood pressure in most patients with renovascular hypertension. However, it may also induce further renal hypoperfusion and thus accelerate progressive loss of renal tissue. Furthermore, case reports of patients with resistant hypertension showing substantial blood pressure improvement after successful revascularization are published over again. To identify those patients who would definitely respond to renal artery stenting, properly designed randomized clinical trials are definitely needed.

  14. Causes and prevention of in-stent restenosis of vertebral artery origin after stenting

    International Nuclear Information System (INIS)

    Zhao Huipin; Li Shenmao; Zhang Guangping

    2010-01-01

    Vertebral artery stenosis is an important cause of posterior circulation stroke. Vertebral artery stenosis most commonly occurs at its origin site. In recent years, balloon angioplasty and stent implantation have been widely employed in the treatment of vertebral artery origin stenosis. However, the long term outcome of stent implantation is affected by in-stent restenosis. Multiple contributory factors have been identified, but clear understanding of the overall underlying mechanism remains an enigma. With the development of pathophysiology, prevention and treatment methods of in-stent restenosis have been improved. In recent years, drug-eluting stents, radioactive stents and magnetic stents have been widely applied. To some extent, these stents and drug therapy can solve the problem of restenosis. This article aims to review the clinical application and the up-to-date research progresses in preventing and managing vertebral artery origin restenosis. (authors)

  15. Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Woo; Kim, Dong Hyun; Hong, Seung; Jeong; Kim, Young Suk; Byun, Joo Nam; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Ahn, Seong Hwan [Dept. of Neurology, Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2011-10-15

    To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient.

  16. Risk Factors and Clinical Evaluation of Superficial Femoral Artery Stent Fracture: Prote'ge'GPS Stent

    International Nuclear Information System (INIS)

    Lee, Da Un; Kim, Jae Kyu; Jung, Hye Doo; Huh, Tae Wook; Yim, Nam Yeol; Oh, Hyun jun; Choi, Soo Jin Na; Chang, Nam Kyu

    2010-01-01

    To evaluate the occurrence of superficial femoral artery stent fractures, the risk factors of stent fracture, and the relationship between fractures and clinical findings. Of the 38 patients who underwent treatment with Prote'ge'GPS stenting due to arterial occlusions on the superficial femoral artery, 17 also underwent a clinical analysis. Forty-three stents were inserted in the 17 superficial femoral arteries, ranging between 15 and 50 cm in length, with a mean treated length of 26.4 cm (15-50 cm). A fracture was evaluated by taking a PA and lateral simple radiography, as well as a follow-up evaluation accompanied with a CT angiography, DSA, and a color Doppler sonography. The examination involved the assessment of the difference between bone fractures due to length, placement, and frequency. Fractures occurred in 13 of 43 stents (30.2%). A total of 10 (71.4%) occurred in the upper third, compared to 4 (28.6%) in the lower third of the superficial femoral artery. In addition, 10 stents (71.4%) had a single strut fracture, whereas 4 (28.6%) had multiple strut fractures. A stent fracture occurred more frequently when the stents and lesions were longer (p=0.021, 0.012) and the stents were inserted near the joint. However, there was no significant relationship between stent numbers and the fractures (p=0.126). When the stents were inserted along the popliteal artery, a stent fracture occurred more frequently in the lower third of the artery. The stent fractures did not significantly influence the patency rate of the stented artery (p=0.44) Prote'ge'GPS stents in the superficial femoral artery revealed a considerable number of fractures and the fracture frequency showed a significant relationship with the length of stents and lesions. The closer stent insertion was to the joints, the more frequently fractures occurred. There were no evident significant relationships between the presence of stent fractures and the patency of the stented arteries

  17. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  18. Angioplasty and stent placement - peripheral arteries

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007393.htm Angioplasty and stent placement - peripheral arteries To use the sharing features ... inside the arteries and block blood flow. A stent is a small, metal mesh tube that keeps ...

  19. Endovascular rescue from arterial rupture and thrombosis during middle cerebral artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, J.Y.; Chung, Y.S. [Department of Neurosurgery, College of Medicine, Pundang CHA Hospital, 351 Yatap-ding, Pundang-gu, 463-712, Sungnam (Korea); Lee, B.H. [Department of Interventional Neuroradiology, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea); Kim, O.J. [Department of Emergency Medicine, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea)

    2003-08-01

    Intravascular stents are being used with increasing frequency in interventional neuroradiology. Iatrogenic arterial rupture is an uncommon but serious complication. We present a case of arterial rupture and subarachnoid haemorrhage during middle cerebral artery stenting, treated by emergency additional, overlapping stenting and balloon tamponade of the dissected vessel. Thrombotic occlusion of the artery was managed by intra-arterial abciximab. Normal vessel patency was re-established within 20 min and the patient recovered with no neurological deficit. (orig.)

  20. FFR-guided multivessel stenting reduces urgent revascularization compared with infarct-related artery only stenting in ST-elevation myocardial infarction: A meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Gupta, Ankur; Bajaj, Navkaranbir S; Arora, Pankaj; Arora, Garima; Qamar, Arman; Bhatt, Deepak L

    2018-02-01

    Randomized controlled trials (RCTs) have shown fractional flow reserve-guided (FFR) multivessel stenting to be superior to infarct-related artery (IRA) only stenting in patients with ST-elevation myocardial infarction (STEMI) and multivessel disease. This effect was mainly driven by a reduction in overall repeat revascularization. However, the ability to assess the effect of this strategy on urgent revascularization or reinfarction was underpowered in individual trials. We searched Pubmed, EMBASE, Cochrane CENTRAL, and Web of Science for RCTs of FFR-guided multivessel stenting versus IRA-only stenting in STEMI with multivessel disease. The outcomes of interest were death, reinfarction, urgent, and non-urgent repeat revascularization. Risk ratios (RR) were pooled using the DerSimonian and Laird random-effects model. After review of 786 citations, 2 RCTs were included. The pooled results demonstrated a significant reduction in the composite of death, reinfarction, or revascularization in the FFR-guided multivessel stenting group versus IRA-only stenting group (RR [95%, Confidence Interval]: 0.49 [0.33-0.72], p<0.001). This risk reduction was driven mainly by a reduction in repeat revascularization, both urgent (0.41 [0.24-0.71], p=0.002) and non-urgent revascularization (0.31 [0.19-0.50], p<0.001). Pooled RR for reinfarction was lower in the FFR-guided strategy, but was not statistically significant (0.71[0.39-1.31], p=0.28). This systematic review and meta-analysis suggests that a strategy of FFR-guided multivessel stenting in STEMI patients reduces not only overall repeat revascularization but also urgent revascularization. The effect on reinfarction needs to be evaluated in larger trials. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  1. Delayed cerebral infarction due to stent folding deformation following carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kwon Duk; Lee, Kyung Yul; Suh, Sang Hyun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    We report a case of delayed cerebral infarction due to stent longitudinal folding deformation following carotid artery stenting using a self-expandable stent with an open-cell design. The stented segment of the left common carotid artery was divided into two different lumens by this folding deformation, and the separated lumens became restricted with in-stent thrombosis. Although no established method of managing this rare complication exists, a conservative approach was taken with administration of anticoagulant and dual antiplatelet therapy. No neurological symptoms were observed during several months of clinical follow-up after discharge.

  2. Usefulness of CT angiography after metallic stent implantation of the internal carotid artery

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyeon Chul; Kim, Jae Kyu; Seo, Jeong Jin; Jeong, Gwang Woo; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of CT angiography in patients with implantation of metallic stent for stenosed internal carotid artery. Seven patients with atherosclerotic stenosis of the internal carotid artery underwent metallic stent implantation. All were male and their ages ranged from 36 to 69 years. A total of seven stents were placed in the internal carotid artery in five patients and in the carotid bifurcation in two. Spiral CT scans were obtained and CT angiographic images were reconstructed using MPR or curved MPR techniques at a workstation. The interval between CT and conventional angiography did not exceed six days except in one patient, in whom it was 61days. CT and conventional angiography were compared for stent position with respect to the carotid bifurcation, stent deformation, intraluminal filling defect, and luminal caliber and outflow. Luminal patency of the implanted stent was measured according to NASCET(North American Symptomatic Carotid Endarterectomy Trial) criteria, and statistically processed (p>.05). The presence or absence of intrastent thrombus and vascular wall calcification was determined using axial source images. In all patients, CT angiographic findings matched those obtained by conventional angiography. Complications such as migration or deformation of an implanted stent, intraluminal filling defect, change of luminal caliber or outflow of implanted stent were not observed in any patient. In two studies in which Wilcoxon signed rank test was used, degree of stent expansion correlated closely(p=0.237). Axial source images showed that in no patient was an intrastent thrombus present, though in five, vascular wall calcification of internal carotid arteries outside the stent was noted. CT angiography is useful for the assessment of positional change, occlusion, and luminal patency of a stent-implanted internal carotid artery

  3. Angioplasty and stent placement - carotid artery

    Science.gov (United States)

    ... medlineplus.gov/ency/article/002953.htm Angioplasty and stent placement - carotid artery To use the sharing features ... to remove plaque buildup ( endarterectomy ) Carotid angioplasty with stent placement Description Carotid angioplasty and stenting (CAS) is ...

  4. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...

  5. Renal artery stent angioplasty for renovascular hypertension

    International Nuclear Information System (INIS)

    Li Gang; Li Haiqing; Wang Lin

    2005-01-01

    Objective: To evaluate the therapeutic results of expandable stent for treatment of atherosclerotic renovascular obstructive disease. Methods: 15 patients (10 men and 5 women, 41-75 years old; mean age, 52 years) with renal arterial hypertension underwent renal stent angioplasty including renal arterial stenosis 89%(n=13) and fully obstruction without function in 2, of which 2 patients had bilateral involvement. The stenotic range of all arterial segments showed 60% to 90% width of the normal arterial diameter. 16 stents were implanted under the guidance of fluoroscopy. The most of stents implanted were Palmaz (n=12, 75%) with regular clinical and angiographic follow up. Results: Technical success (residual stenosis <30%) was achieved in all patients without serious complication. During the follow-up (6-15 months; mean, 8 ± 4 months), hypertension was improved in 9 patients and cured in 4 patients with a total benefit of 86% and no efficacy in 2(13%). The average systolic blood pressure decreased from 27.12 ± 3.09 kPa to 18.62 ± 3.12 kPa and the average diastolic blood pressure decreased from 17.73 ± 1.92 kPa to 11.12 ± 2.43 kPa after stent treatment (P<0.05). Serum creatinine remained stable in 60% (n=9) patients with improvement in 33% (n=5) and worsened in 6% (n=1) patients. Follow-up angiography was performed in all patients with 1 case of a restenosis. 6 months after expanding through stent by using balloon, the two follow up angiographies showed a stable restenosis about 20%. Conclusions: Percutaneous transluminal stent placement is highly beneficial for patients who had renal arterial obstructive disease. The success of stent angioplasty of complete obstructive renal arteries reveals wide prospects for interventional method. (authors)

  6. Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease

    DEFF Research Database (Denmark)

    Raungaard, Bent; Christiansen, Evald H; Bøtker, Hans Erik

    2017-01-01

    artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion......OBJECTIVES: The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients. BACKGROUND: Biodegradable-polymer biolimus-eluting stents are superior to first......-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking. METHODS: The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary...

  7. Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

    International Nuclear Information System (INIS)

    Saguner, Ardan M.; Traupe, Tobias; Räber, Lorenz; Hess, Nina; Banz, Yara; Saguner, Arhan R.; Diehm, Nicolas; Hess, Otto M.

    2012-01-01

    Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5–6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into “normal-sized” (stent-to-artery-ratio < 1.4, n = 12) and “oversized” (stent-to-artery-ratio ≥ 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

  8. In-stent restenosis of innominate artery with critical stenosis of right internal carotid artery

    International Nuclear Information System (INIS)

    Hussain, S.; Raza, A.; Ahmed, W.

    2011-01-01

    A lady with aortitis syndrome developed in-stent restenosis (ISR) of the innominate artery stent and critical stenosis of right internal carotid artery. The therapeutic challenge was gaining access to the carotid vessel, after treating the innominate artery ISR and all the while using distal protection to circumvent potential cerebral embolism. Percutaneous transluminal angioplasty (PTA) with or without stenting is a safe therapeutic option for re-vascularization of the supra aortic vessels. In the event of re-stenosis, re-treatment with PTA and stenting is safe. Ample evidence-base exists now for carotid artery stenting (CAS) in preference to carotid endarterectomy in patients with stenotic lesions of the carotid vessels. (author)

  9. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    Science.gov (United States)

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  10. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    Science.gov (United States)

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, pB2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, pSPIRIT II trial population.

  11. Predictive Factors of In-Stent Restenosis in Renal Artery Stenting: A Retrospective Analysis

    International Nuclear Information System (INIS)

    Vignali, Claudio; Bargellini, Irene; Lazzereschi, Michele; Cioni, Roberto; Petruzzi, Pasquale; Caramella, Davide; Pinto, Stefania; Napoli, Vinicio; Zampa, Virna; Bartolozzi, Carlo

    2005-01-01

    Purpose. To retrospectively evaluate the role of clinical and procedural factors in predicting in-stent restenosis in patients with renovascular disease treated by renal artery stenting. Methods. From 1995 to 2002, 147 patients underwent renal artery stenting for the treatment of significant ostial atherosclerotic stenosis. Patients underwent strict clinical and color-coded duplex ultrasound follow-up. Ninety-nine patients (111 stents), with over 6 months of continuous follow-up (mean 22±12 months, range 6-60 months), were selected and classified according to the presence (group A, 30 patients, 32 lesions) or absence (group B, 69 patients, 79 lesions) of significant in-stent restenosis. A statistical analysis was performed to identify possible preprocedural and procedural predictors of restenosis considering the following data: sex, age, smoking habit, diabetes mellitus, hypertension, serum creatinine, cholesterol and triglyceride levels, renal artery stenosis grade, and stent type, length and diameter. Results. Comparing group A and B patients (χ 2 test), a statistically significant relation was demonstrated between stent diameter and length and restenosis: the risk of in-stent restenosis decreased when the stent was ≥6 mm in diameter and between 15 and 20 mm in length. This finding was confirmed by multiple logistic regression analysis. Stent diameter and length were proved to be significantly related to in-stent restenosis also when evaluating only patients treated by Palmaz stent (71 stents). Conclusion. Although it is based on a retrospective analysis, the present study confirms the importance of correct stent selection in increasing long-term patency, using stents of at least 6 mm in diameter and with a length of approximately 15-20 mm

  12. Stent-induced flow disturbances in the ipsilateral external carotid artery following internal carotid artery stenting: a temporary cause of jaw claudication.

    Science.gov (United States)

    Giurgea, Georgiana-Aura; Haumer, Markus; Mlekusch, Irene; Sabeti-Sandor, Schila; Dick, Petra; Schillinger, Martin; Minar, Erich; Mlekusch, Wolfgang

    2017-07-01

    We hypothesize that stenting of the internal carotid artery can immediately impede blood flow to the external carotid artery by either plaque shift or stent coverage of the ostium, and thereby cause ischemic symptoms like ipsilateral jaw claudication. Thirty-three patients with high-grade asymptomatic stenosis of the internal carotid artery who underwent endovascular treatment were examined by ultrasound of the external carotid artery and performed an exercise test by chewing chewing gum synchronously to an electronic metronome for 3 min. Tests were performed before, the day after, and 1 week after the stenting procedure. Claudication time was defined as the timespan until occurrence of pain of the masseter muscle and/or chewing dyssynchrony to the metronome for more than 15 s. Ten patients with an isolated, atherosclerotic stenosis of the external carotid artery served as controls. A significantly reduced claudication time (in seconds) was recorded in patients who underwent carotid artery stenting compared to baseline values; median 89 (interquartile range, IQR, 57 to 124) vs. median 180 (IQR 153 to 180; p external carotid artery into faster or slower as 200 cm/sec, the effect was even accentuated. Stenting values showed improvement 1 week after but did not return to baseline levels. No respective changes were found in controls. Stenting of the internal carotid artery lead to ipsilateral flow deterioration at the external carotid artery resulting in temporary jaw claudication. This impairment attenuated over the time and was significantly reduced after 1 week.

  13. Stent Design Affects Femoropopliteal Artery Deformation.

    Science.gov (United States)

    MacTaggart, Jason; Poulson, William; Seas, Andreas; Deegan, Paul; Lomneth, Carol; Desyatova, Anastasia; Maleckis, Kaspars; Kamenskiy, Alexey

    2018-03-23

    Poor durability of femoropopliteal artery (FPA) stenting is multifactorial, and severe FPA deformations occurring with limb flexion are likely involved. Different stent designs result in dissimilar stent-artery interactions, but the degree of these effects in the FPA is insufficiently understood. To determine how different stent designs affect limb flexion-induced FPA deformations. Retrievable markers were deployed into n = 28 FPAs of lightly embalmed human cadavers. Bodies were perfused and CT images were acquired with limbs in the standing, walking, sitting, and gardening postures. Image analysis allowed measurement of baseline FPA foreshortening, bending, and twisting associated with each posture. Markers were retrieved and 7 different stents were deployed across the adductor hiatus in the same limbs. Markers were then redeployed in the stented FPAs, and limbs were reimaged. Baseline and stented FPA deformations were compared to determine the influence of each stent design. Proximal to the stent, Innova, Supera, and SmartFlex exacerbated foreshortening, SmartFlex exacerbated twisting, and SmartControl restricted bending of the FPA. Within the stent, all devices except Viabahn restricted foreshortening; Supera, SmartControl, and AbsolutePro restricted twisting; SmartFlex and Innova exacerbated twisting; and Supera and Viabahn restricted bending. Distal to the stents, all devices except AbsolutePro and Innova exacerbated foreshortening, and Viabahn, Supera, Zilver, and SmartControl exacerbated twisting. All stents except Supera were pinched in flexed limb postures. Peripheral self-expanding stents significantly affect limb flexion-induced FPA deformations, but in different ways. Although certain designs seem to accommodate some deformation modes, no device was able to match all FPA deformations.

  14. MRT of carotid stents: influence of stent properties and sequence parameters on visualization of the carotid artery lumen

    International Nuclear Information System (INIS)

    Straube, T.; Wolf, S.; Alfke, K.; Jansen, O.; Flesser, A.; Deli, M.; Nabavi, A.

    2005-01-01

    Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no significant influence on radiofrequency artifacts, whereas a reduction in linking elements between stent segments and a change in diameter of stent struts improves visualization of the stent lumen. By increasing the flip angle in a CE-MRA, visualization of the stent lumen is possible in both mediloy and nitinol stents. Conclusion: The choice of stent material and changes in stent geometry as well as the optimization of the flip angle of the CE-MRA may reduce susceptibility and radiofrequency artifacts, rendering feasible the CE-MRA of a stented carotid artery. (orig.)

  15. Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries

    International Nuclear Information System (INIS)

    Goltz, J.P.; Kickuth, R.; Bastuerk, P.; Hoppe, H.; Triller, J.

    2011-01-01

    Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)

  16. An argument for the use of multiple segment stents in curved arteries.

    Science.gov (United States)

    Kasiri, Saeid; Kelly, Daniel J

    2011-08-01

    Stenting of curved arteries is generally perceived to be more challenging than straight vessels. Conceptually implanting multiple shorter stents rather than a single longer stent into such a curved artery represents a promising concept, but little is known about the impact of such an approach. The objective of this study is to evaluate the effectiveness of using a multiple segment stent rather than a single long stent to dilate a curved artery using the finite element method. A double segment stent (DSS) and a single segment stent (SSS) were modeled. The stents were compared when expanded into a model of a curved artery. The model predicts that the DSS provides higher flexibility, more conformity, and lower recoil in comparison to the SSS. The volume of arterial tissue experiencing high levels of stress due to stent implantation is also reduced for the DSS. It is suggested that a multiple segment stenting system is a potential solution to the problem of higher rates of in-stent restenosis in curved arteries and mechanically challenging environments.

  17. Acute Carotid Artery Stent Thrombosis Due to Dual Antiplatelet Resistance

    International Nuclear Information System (INIS)

    Köklü, Erkan; Arslan, Şakir; Yüksel, İsa Öner; Bayar, Nermin; Koç, Pınar

    2015-01-01

    Carotid artery stenting (CAS) is a revascularization modality that is an alternative to carotid endarterectomy. The efficacy of CAS in primary and secondary prevention from ischemic stroke has been demonstrated in various trials. Acute thrombosis of CAS is a rare complication that can lead to dramatic and catastrophic consequences. We discuss a case of acute CAS thrombosis in a patient who had previously undergone successful CAS. CAS was performed in a 73-year-old man who had had dysarthria lasting 2 weeks with 95 % stenosis in his left internal carotid artery. An acute cerebrovascular event resulting in right-sided hemiplegia developed 24 h after the procedure. Computed tomographic carotid angiography revealed complete occlusion of the stent with thrombus. The cause of stent thrombosis was thought to be antiaggregant resistance to both acetylsalicylic acid and clopidogrel. The most important cause of acute CAS thrombosis is inadequate or ineffective antiaggregant therapy. Evaluating patients who are candidates for CAS for acetylsalicylic acid and clopidogrel resistance may preclude this complication

  18. Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials.

    Science.gov (United States)

    Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W

    2011-10-01

    This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p SPIRIT II]; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the

  19. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    International Nuclear Information System (INIS)

    Chalmers, Nicholas; Walker, Paul T.; Belli, Anna-Maria; Thorpe, Anthony P.; Sidhu, Paul S.; Robinson, Graham; Ransbeeck, Mariella van; Fearn, Steven A.

    2013-01-01

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5–22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months’ follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  20. Renal PTA stenting

    International Nuclear Information System (INIS)

    Tsetis, D.

    2012-01-01

    Full text: Renal artery stenosis (RAS) is a common condition that may lead to hypertension, progressive renal dysfunction and cardiovascular morbidity. Catheter-based therapy for symptomatic, haemodynamically significant, RAS has become the preferred method of revascularization. Balloon angioplasty has been the traditional treatment of choice for fibromuscular dysplasia, however stents are increasingly used for the treatment of atheromatous lesions; in many cases-such as in ostial lesions-, direct stenting is strongly indicated. Despite the increased use of endovascular therapy for renal artery stenosis, there is still controversy regarding the optimal management and the net benefit of this treatment. Several randomized trials of balloon angioplasty or stenting for renal artery stenosis compared with medical therapy alone have been conducted, however these could not show definite advantage of endovascular therapy. Problems encountered with those trials include enrollment of small number of patients, frequent crossover from medical to interventional therapy compromising the intention-to-treat results, or selection of patients that are not expected to show clear benefit. The Angioplasty and Stenting for Renal Artery Lesions (ASTRAL) is the most important of these trials; however, it,s study design was faulty and therefore did not provide conclusive evidence to answer the question of whether angioplasty and stenting or medical therapy is the best treatment for haemodynamically significant RAS. All expectations are now focused on the Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial which was designed to answer the same question, and its methodologies took into consideration the weaknesses of the ASTRAL trial. Regarding stent device itself, it seems that the optimal design is probably a stainless steel, laser cut, open-cells stent mounted on a rapid exchange delivery balloon catheter compatible with 0.014-in and 0.018-in guidewire. As a future

  1. Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

    Science.gov (United States)

    Lettau, Michael; Bendszus, Martin; Hähnel, Stefan

    2013-06-01

    Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.

  2. Metallic stent for the treatment of iliac arterial stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Chung, Jin Wook; Han, Joon Koo; Suh, Chul Soo; Yoo, Jae Wook; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of); Song, Chi Sung [Seoul City Boramae Hospital, Seoul (Korea, Republic of)

    1993-07-15

    In order to study the clinical efficacy of the metallic stent of the treatment of iliac arterial stenosis, the clinical and arteriographic findings of the 8 patients were retrospectively reviewed. All 8 patients were males with an age of 51 to 79. The Fontaine class for the functional status of lower extremities was II in 4 patients, III in 3 patents and IV in 1 patient. Self expandable Gianturco stent was inserted of in 7 iliac arteries and balloon expandable Palmaz stent was inserted in 2 iliac arteries in the 8 patients. The indications for the metallic stent application were localized dissection with significant residual stenosis in 6 sites, recoiling due to calcification in one case and eccentricity of the stenosislesionin 2 sites. The deployment of the metallic stent was successful in all the cases to maintain the patency of iliac arteries with residual stenosis less than 30%. The Fontaine class was improved to 1 in 6 patients, IIa in 1 patient and IIb in another one. During the follow up period of 3 to 14 month, none except one developed recurrence of the symptom. On the basis of our experience, we believe that metallic stent is safe and effective for the treatment of iliac arterial stenosis. However, we think that it is a complementary measure to the percutaneous transluminal angioplasty. The comparative study between different types of metallic stent and the long term effect should be investigated further.

  3. Angioplasty and stent placement - carotid artery - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000235.htm Angioplasty and stent placement - carotid artery - discharge To use the sharing ... the hospital. You may have also had a stent (a tiny wire mesh tube) placed in the ...

  4. Hepatic artery stent-grafts for the emergency treatment of acute bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Bellemann, Nadine, E-mail: nadine.bellemann@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sommer, Christof-Matthias; Mokry, Theresa; Kortes, Nikolas; Gnutzmann, Daniel; Gockner, Theresa; Schmitz, Anne [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Weitz, Jürgen [Department of Surgery, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Department for Visceral, Thoracic and Vascular Surgery at the University Hospital, Technical University Dresden (Germany); Kauczor, Hans-Ulrich; Radeleff, Boris; Stampfl, Ulrike [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)

    2014-10-15

    Highlights: • We report our experiences with stent-grafts for the treatment of acute hemorrhage from the hepatic artery or the stump of the gastroduodenal artery. • The technical success of stent-graft implantation was 88%. • The bleeding ceased immediately after stent-graft implantation in 88%. • The complication rate was 21%. - Abstract: Purpose: We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. Methods: Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. Results: In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n = 16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4 mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. Conclusions: Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.

  5. COVERED STENTS IN IATROGENIC CORONARY ARTERY FISTULA; A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Masoud Poormoghaddas

    2010-11-01

    Full Text Available Abstract    BACKGROUND: Coronary artery fistula is an abnormal communication between a coronary artery and a cardiac chamber or major cardiac vessels, mostly congenital but some of them are acquired as a consequence of coronary artery perforation.    CASE PRESENTATION: We report a case of cavity spilling coronary artery perforation during percutaneous coronary intervention 7 years ago. Because of continuing symptoms and risk of developing heart failure and pulmonary hypertension we were ought to treat this iatrogenically formed coronary artery fistula. We used stent graft implantation to treat it with acceptable results.    CONCLUSION: Beside their application as a rescue for acute coronary artery perforations, stent grafts can be used with acceptable results in iatrogenically acquired coronary artery coronary artery fistula      Keywords: Coronary artery perforation, Coronary artery fistula, Stent graft.

  6. Primary stent placement for recanalization of iliac artery occlusions: Using a self-expanding spiral stent

    International Nuclear Information System (INIS)

    Kim, Jae-Kyu; Kim, Yun-Hyeon; Chung, Sang-Yeung; Kang, Heoung-Keun

    1999-01-01

    Purpose: To report the clinical results for recanalizations of an occluded iliac artery by a self-expanding spiral stent.Methods: We attempted to recanalize 36 iliac artery occlusions in 34 patients [33 men, 1 woman, aged 51-75 years (average 61.6 years)]. The average lesion length was 6.92 cm (range 1-14 cm). The patients's chief complaints were intermittent claudication and resting pain. Fontaine classification was assigned before and after the procedure. Technical and clinical success were also analyzed.Results: Forty-five stents were successfully deployed in 34 patients. All 36 lesions (13 in the external iliac artery, 12 in the common iliac artery, and 11 in both) were patently recanalized on angiography. The follow-up period ranged from 6 months to 36 months (mean 11.9 months). Fourteen stents (39%) with incomplete expansion were dilated with a balloon catheter. Good technical (100%) and clinical (94%) results were obtained. The only complication was one hematoma at the puncture site. Reocclusions were noted in two lesions (5%) at 1 week and 15 months, respectively.Conclusion: A self-expanding spiral stent is a safe and effective device for recanalization of an iliac artery occlusion as the primary stent without any previous intervention.

  7. Temporary stenting and retrieval of the self-expandable, intracranial stent in acute middle cerebral artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Sang Hyun; Chung, Tae-Sub [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea); Lee, Kyung-Yul [Yonsei University College of Medicine, Department of Neurology, Gangnam Severance Hospital, Seoul (Korea); Hong, Chang Ki; Kim, Chang-Hyun [Yonsei University College of Medicine, Department of Neurosurgery, Gangnam Severance Hospital, Seoul (Korea); Kim, Byung Moon; Kim, Dong Ik [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea)

    2009-08-15

    We describe our experience in which a retrievable Enterprise stent was used as a temporary recanalization and embolectomy device in an acute middle cerebral artery (MCA) occlusion after urgent stenting for ipsilateral carotid artery stenosis. (orig.)

  8. Experimental study of the preventive effect of 1'03Pd stent on in-stent restenosis in rabbit iliac artery

    International Nuclear Information System (INIS)

    Luo Quanyong; Chen Libo; Yuan Zhibin; Lu Hankui; Zhu Ruisen

    2003-01-01

    Objective: To investigate the ability of γ-emitting 103 Pd radioactive stent implantation for preventing in-stent restenosis in iliac artery of rabbits. Methods: Twenty New Zealand white rabbits were divided into six groups on the basis of radioactivity loading [2.22 (n=3), 5.55 (n=4), 9.25 (n=4), 14.8 (n=3), 22.2 (n=3), 33.3 MBq (n=3)]. 103 Pd stent was implanted in one of the two iliac arteries of each rabbit and nonradioactive stent in the contralateral artery. The rabbits were fed with high fat diet. Treatment efficiency was assessed by angiography and quantitative histomorphometry of the stented iliac segments 28 d after the implantation. Results: Quantitative histomorphometry analysis indicated that 103 Pd stents induced a significant reduction in neointimal area and the percentage of stenosis within radioactive stents was lower compared with that in the control stents. Nevertheless, the suppression of neointima formation by 103 Pd stent implantation was not in a dose-dependent manner. Conclusions: Low-dose intravascular brachytherapy via a γ-particle-emitting 103 Pd radioactive stent potently inhibits neointimal hyperplasia and prevents the in-stent restenosis in rabbit iliac artery. 103 Pd stent implantation probably can be employed as a novel means to prevent in-stent restenosis

  9. Successful treatment of coronary artery pseudoaneurysm by graft stent, which developed after the implantation of bare metal stent

    Directory of Open Access Journals (Sweden)

    Utku Şenol

    2013-03-01

    Full Text Available Although coronary artery pseudoaneurysm which couldoccur following percutaneous coronary interventions is arare complication, it can be mortal. As soon as the pseudoaneurysmis diagnosed, it should be treated by percutaneousintervention or surgery. Graft stent implantationis a preferred treatment for appropriate patients. In thiscase report, we presented a successful treatment of coronaryartery pseudoaneurysm by graft stent; which developedafter the implantation of bare metal stent into theleft anterior descending coronary artery. J Clin Exp Invest2013; 4 (1: 126-129Key words: Coronary artery, pseudoaneurysm, graft stent

  10. The EPIC nitinol stent system in the treatment of iliac artery lesions: one-year results from the ORION clinical trial.

    Science.gov (United States)

    Clair, Daniel G; Adams, Julie; Reen, Bernard; Feldman, Robert; Starr, Jean; Diaz-Cartelle, Juan; Dawkins, Keith D

    2014-04-01

    To report the 1-year results of a pivotal study for a new-generation nitinol stent for the treatment of iliac atherosclerotic lesions. The ORION trial (ClinicalTrials.gov identifier NCT00896337) was a single-arm, non-randomized, prospective, multicenter clinical trial that enrolled 125 patients (81 men; mean age 61.1±9.3 years) implanted with the EPIC self-expanding nitinol stent system in 166 de novo or restenotic iliac artery lesions ≤13 cm long. The primary endpoint was the 9-month major adverse event rate [i.e., device- or procedure-related death within 30 days, myocardial infarction during the index hospitalization, target vessel revascularization (TVR), or index limb amputation]. Follow-up occurred at hospital discharge and at 1, 9, and 12 months. An independent core laboratory evaluated ultrasound results at 1, 9, and 12 months. The primary endpoint met the prespecified performance goal, with only 3.4% (4/117) of patients experiencing a major adverse event by 9 months (p<0.0001). By 12 months, 6 (5.4%) of 111 patients had TVR; none had an index limb amputation. The ankle-brachial index, Walking Impairment Questionnaire, and Rutherford classifications all showed sustained improvements through 12 months. Primary patency was 94.4% with comparable results for lesions classified as complex (TASC II C/D 95.5%) or non-complex (TASC II A/B 95.0%). The EPIC stent system demonstrated safety and effectiveness through 12 months, including improvements for complex lesions. The EPIC stent is a viable alternative to surgery for patients with either complex or non-complex lesions.

  11. Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

    Science.gov (United States)

    Waseda, Katsuhisa; Ako, Junya; Yamasaki, Masao; Koizumi, Tomomi; Sakurai, Ryota; Hongo, Yoichiro; Koo, Bon-Kwon; Ormiston, John; Worthley, Stephen G; Whitbourn, Robert J; Walters, Darren L; Meredith, Ian T; Fitzgerald, Peter J; Honda, Yasuhiro

    2011-06-01

    Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7±4.0, Endeavor: 17.5±10.1, ZoMaxx: 14.6±8.1, Driver: 29.4±17.2%; Ppolymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents. The different polymer formulations significantly affect the relative amount of neointima for zotarolimus-eluting stents. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00248079.

  12. Complication rate in unprotected carotid artery stenting with closed-cell stents

    International Nuclear Information System (INIS)

    Tietke, Marc W.K.; Kerby, Tina; Alfke, Karsten; Riedel, Christian; Rohr, Axel; Jensen, Ulf; Jansen, Olaf; Zimmermann, Phillip; Stingele, Robert

    2010-01-01

    The discussion on the use of protection devices (PDs) in carotid artery stenting (CAS) is gaining an increasing role in lowering the periprocedural complication rates. While many reviews and reports with retrospective data analysis do promote the use of PDs the most recent multi-centre trials are showing advantages for unprotected CAS combined with closed-cell stent designs. We retrospectively analysed 358 unprotected CAS procedures performed from January 2003 to June 2009 in our clinic. Male/female ratio was 2.68/1. The average age was 69.3 years. Seventy-three percent (261/358) showed initial neurological symptoms. All patients were treated on a standardised interventional protocol. A closed and small-sized cell designed stent was implanted in most cases (85.2%). One hundred seventy-one (47.8%) were controlled by Doppler ultrasonography usually at first in a 3-month and later in 6-month intervals. The peri-interventional and 30-day mortality/stroke rate was 4.19% (15/358). These events included three deaths, five hyperperfusion syndromes (comprising one death by a secondary fatal intracranial haemorrhage), one subarachnoid haemorrhage and seven ischaemic strokes. Only 20% (3/15) of all complications occurred directly peri-interventional. The overall peri-interventional complication rate was 0.8% (3/358). Most complications occurred in initial symptomatic patients (5.36%). The in-stent restenosis rate for more than 70% was 7% (12/171) detected at an average of 9.8 month. Our clinical outcome demonstrates that unprotected CAS with small cell designed stents results in a very low procedural complication rate, which makes the use of a protection device dispensable. (orig.)

  13. Flow Velocities After Carotid Artery Stenting: Impact of Stent Design. A Fluid Dynamics Study in a Carotid Artery Model with Laser Doppler Anemometry

    International Nuclear Information System (INIS)

    Greil, Oliver; Kleinschmidt, Thomas; Weiss, Wolfgang; Wolf, Oliver; Heider, Peter; Schaffner, Silvio; Gianotti, Marc; Schmid, Thomas; Liepsch, Dieter; Berger, Hermann

    2005-01-01

    Purpose. To study the influence of a newly developed membrane stent design on flow patterns in a physiologic carotid artery model. Methods. Three different stents were positioned in silicone models of the carotid artery: a stainless steel stent (Wall-stent), a nitinol stent (SelfX), and a nitinol stent with a semipermeable membrane (MembraX). To increase the contact area of the membrane with the vessel wall, another MembranX model was modified at the outflow tract. The membrane consists of a biocompatible silicone-polyurethane copolymer (Elast-Eon) with a pore size of 100 μm. All stents were deployed across the bifurcation and the external carotid artery origin. Flow velocity measurements were performed with laser Doppler anemometry (LDA), using pulsatile flow conditions (Re = 220; flow 0.39 l/min; flow rate ratio ICA:ECA = 70:30) in hemodynamically relevant cross-sections. The hemodynamic changes were analyzed by comparing velocity fluctuations of corresponding flow profiles. Results. The flow rate ratio ICA:ECA shifted significantly from 70/30 to 73.9/26.1 in the MembraX and remained nearly unchanged in the SelfX and Wallstent. There were no changes in the flow patterns at the inflow proximal to the stents. In the stent no relevant changes were found in the SelfX. In the Wallstent the separation zone shifted from the orifice of the ICA to the distal end of the stent. Four millimeters distal to the SelfX and the Wallstent the flow profile returned to normal. In the MembraX an increase in the central slipstreams was found with creation of a flow separation distal to the stent. With a modification of the membrane this flow separation vanished. In the ECA flow disturbances were seen at the inner wall distal to the stent struts in the SelfX and the Wallstent. With the MembraX a calming of flow could be observed in the ECA with a slight loss of flow volume. Conclusions. Stent placement across the carotid artery bifurcation induces alterations of the physiologic flow

  14. Transpedal approach for iliac artery stenting: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Zachariah, Jips J., E-mail: jzachariah@chpnet.org [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Ratcliffe, Justin A.; Ruisi, Michael; Puma, Joseph [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Bertrand, Olivier [Quebec Heart and Lung Institute, Quebec (Canada); Kwan, Tak [Mount Sinai Beth Israel Hospital, New York, NY (Israel)

    2016-12-15

    Objective: To demonstrate the safety and feasibility of the transpedal approach as an alternate arterial access site for iliac artery intervention. Background: The common femoral artery is the traditional access site for the endovascular treatment of iliac artery stenoses. However, this approach is associated with complication rates as high as 2%, including retroperitoneal bleeding which carries high patient morbidity and mortality. Furthermore, the standard femoral approach is associated with longer recovery times and longer time to ambulation which are important considerations especially when performing procedures in an ambulatory setting. Methods: Twelve patients were prospectively followed after treatment for symptomatic iliac artery stenosis via transpedal access. Under ultrasound guidance, one of the pedal arteries was visualized and accessed, and stenting of the iliac arteries were performed as per protocol. The patient was monitored immediately post procedure and clinical follow up was performed at one week and one month later. Results: The average age of the patients was 71 years old. 58% were male. Most patients had Rutherford class III symptoms. Successful stent placement was achieved in all 12 patients via transpedal access. No conversion to femoral access was required. No complications immediately post procedure nor at any time period during follow up were noted. Lower extremity arterial duplex at one month showed patent stents and patent pedal access site vessels in all patients. Conclusion: Transpedal arterial access may be a safe and feasible approach for iliac artery stenting. Given the possible benefits of avoiding femoral artery access, larger studies should be conducted directly comparing the different approaches.

  15. Treatment of Intra- and Extracranial Arterial Dissections Using Stents and Embolization

    International Nuclear Information System (INIS)

    Joo, Jin Yang; Ahn, Jung Yong; Chung, Young Sun; Han, In Bo; Chung, Sang Sup; Yoon, Pyeong Ho; Kim, Sang Heum; Choi, Eun Wan

    2005-01-01

    Purpose. To evaluate the safety and efficacy of stent placement for extracranial and intracranial arterial dissections. Methods. Eighteen patients underwent endovascular treatment of carotid and vertebral dissections using intraluminal stent placement. Five patients with arterial dissection were treated, 2 using one insertion of a single stent and 3 using placement of two stents. Patients with a dissecting aneurysm were treated as follows: 7 patients with insertion of one stent, 4 with placement of two stents, and 2 by stent-assisted Guglielmi detachable coil embolization. In the 18 patients in whom stenting was attempted, the overall success in reaching the target lesion was 94.4%. Of the 17 patients treated with stents, stent release and positioning were considered optimal in 16 (94%) and suboptimal in one (6%). In patients who underwent a successful procedure, all parent arteries were preserved. There were no instances of postprocedural ischemic attacks, new neurologic deficits, or new minor or major strokes prior to patient discharge. In follow up, all patients were assessed, using the modified Rankin scale, as functionally improved or of stable clinical status. The reduction in dissection-induced stenosis or pseudoaneurysm, the patency rate obtained at follow-up, and the lack of strokes (ischemic or hemorrhagic) suggest that stent placement offers a viable alternative to complex surgical bypass or reconstructive procedures. The long-term efficacy and durability of stent placement for arterial dissection remain to be determined in a larger series

  16. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheng-Hung [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China); Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Jhong, Guan-Heng [Graduate Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan (China); Hsu, Ming-Yi; Wang, Chao-Jan [Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, Taiwan (China); Liu, Shih-Jung, E-mail: shihjung@mail.cgu.edu.tw [Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Hung, Kuo-Chun [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China)

    2014-05-28

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  17. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    International Nuclear Information System (INIS)

    Lee, Cheng-Hung; Jhong, Guan-Heng; Hsu, Ming-Yi; Wang, Chao-Jan; Liu, Shih-Jung; Hung, Kuo-Chun

    2014-01-01

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  18. Long-term outcome in patients treated with sirolimus-eluting stents in complex coronary artery lesions: 3-year results of the SCANDSTENT (Stenting Coronary Arteries in Non-Stress/Benestent Disease) trial

    DEFF Research Database (Denmark)

    Kelbaek, H.; Klovgaard, L.; Helqvist, S.

    2008-01-01

    data of the long-term outcome of patients with complex coronary artery lesions. METHODS: We randomly assigned 322 patients with total coronary occlusions or lesions located in bifurcations, ostial, or angulated segments of the coronary arteries to have SES or BMS implanted. RESULTS: At 3 years, major...... performed between 1 and 3 years after the index treatment (p = NS). According to revised definitions, stent thrombosis occurred in 5 patients (3.1%) in the SES group and in 7 patients (4.4%) in the BMS group (p = NS); very late stent thrombosis was observed in 4 versus 1 patient. CONCLUSIONS: A continued...

  19. The 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE trial: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Park Kyung

    2012-03-01

    Full Text Available Abstract Background Second-generation drug-eluting stents (DES have raised the bar of clinical performance. These stents are mostly made from cobalt chromium alloy. A newer generation DES has been developed from platinum chromium alloy, but clinical data regarding the efficacy and safety of the platinum chromium-based everolimus-eluting stent (PtCr-EES is limited, with no comparison data against the cobalt chromium-based zotarolimus-eluting stent (CoCr-ZES. In addition, an antiplatelet regimen is an integral component of medical therapy after percutaneous coronary intervention (PCI. A 1-week duration of doubling the dose of clopidogrel (double-dose antiplatelet therapy (DDAT was shown to improve outcome at 1 month compared with conventional dose in acute coronary syndrome (ACS patients undergoing PCI. However in Asia, including Korea, the addition of cilostazol (triplet antiplatelet therapy (TAT is used more commonly than doubling the dose of clopidogrel in high-risk patients. Methods In the 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE trial, approximately 3,750 patients are being prospectively and randomly assigned in a 2 × 2 factorial design according to the type of stent (PtCr-EES vs CoCr-ZES and antiplatelet regimen (TAT vs DDAT. The first primary endpoint is target lesion failure at 1 year for the stent comparison, and the second primary endpoint is net clinical outcome at 1 month for comparison of antiplatelet therapy regimen. Discussion The HOST-ASSURE trial is the largest study yet performed to directly compare the efficacy and safety of the PtCr-EES versus CoCr-ZES in an 'all-comers' population. In addition, this study will also compare the clinical outcome of TAT versus DDAT for 1-month post PCI. Trial registration ClincalTrials.gov number NCT01267734.

  20. Renal artery stent fracture with refractory hypertension: a case report and review of the literature.

    Science.gov (United States)

    Chua, Su-Kiat; Hung, Huei-Fong

    2009-07-01

    A 73-year-old man with resistant hypertension and impaired renal function underwent stenting for right renal artery (RRA) stenosis. Two years later, he presented with uncontrolled hypertension and worse renal function. Renal arteriogram revealed RRA stent fracture with in-stent restenosis. Another stent was deployed. Four months later, however, renal arteriogram revealed in-stent restenosis again. This time, balloon angioplasty alone was performed. He had been symptom-free with stable condition at 2-year follow-up. A literature review disclosed six renal artery stent fracture cases, including the present one, who developed in-stent stenosis resulted from stent fracture. Two major anatomy features of renal artery stenosis were suggestive for development of stent fracture: (1) renal artery entrapment by diaphragmatic crus, and (2) mobile kidney with acute angulation at proximal segment of the renal artery. It is important to detect this etiology of renal artery stenosis because stenting in these vessels may contribute to in-stent restenosis or stent fracture. Management of renal artery stent fracture, including endovascular treatment or aortorenal bypass, should be considered on a case-by-case basis in relation to clinical settings. Copyright 2009 Wiley-Liss, Inc.

  1. Mechanical thrombectomy using Rotarex system and stent-in-stent placement for treatment of distal femoral artery occlusion secondary to stent fracture – a case report and literature review

    International Nuclear Information System (INIS)

    Dys, Krzysztof; Drelichowska-Durawa, Justyna; Dołega-Kozierowski, Bartosz; Lis, Michał; Sokratous, Kyriakos; Iwanowski, Wojciech; Drelichowski, Stanisław; Witkiewicz, Wojciech

    2013-01-01

    Treatment of peripheral arterial diseases may be distinguished into conservative and interventional management; the latter is divided into surgical and endovascular procedures. Management of peripheral artery stenosis and occlusion with vascular stents is associated with the risk of late complications such as restenosis, stent fracture or dislocation. A 62-year-old woman with generalized atherosclerosis, particularly extensive in lower limb arteries, was admitted to the Department of Angiology 11 months after having an endovascular procedure performed due to critical ischemia of left lower limb. Because of stent occlusion, a decision to perform angiographic examination of lower limb arteries was made. Examination revealed occlusion of the superficial femoral artery along its entire length, including previously implanted stents. Distal stent was fractured with slight dislocation of the proximal segment. A decision was made to perform mechanical thrombectomy using a Rotarex system followed by a stent-in-stent placement procedure. Follow-up angiography and ultrasound scan performed 24 hours after the procedure revealed a patent vessel with satisfactory blood flow. Nowadays, imaging diagnostics of peripheral artery stenosis involves non-invasive examinations such as ultrasound, minimally invasive examinations such as angio-MRI and MDCT, or invasive examinations such as DSA and IVUS. DSA examinations are used to confirm significant stenosis or occlusion of a vessel, particularly when qualifying a patient for endovascular treatment. Due to their anatomic location, the superficial femoral artery and the popliteal artery are subject to various forces e.g. those exerted by the working muscles. Mechanical thrombectomy and atherectomy are efficient methods of arterial recanalization used in the treatment of acute, subacute or even chronic occlusions or stenosis of peripheral vessels. Frequency of angioplasty and vascular stent implantation procedures is increased in patients

  2. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    International Nuclear Information System (INIS)

    Stoupis, Christoforos; Ludwig, Karin; Triller, Juergen; Inderbitzin, Daniel; Do, Dai-Do

    2007-01-01

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  3. 53. Bilateral ductal stenting for nonconfluent pulmonary arteries in a newborn

    Directory of Open Access Journals (Sweden)

    K. Al Dhahri

    2016-07-01

    Full Text Available Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Limited data available for bilateral PDA stenting. Bilateral PDA stenting in nonconfluent pulmonary arteries is challenging procedure but can be considered as an option in the management of complex conditions like this. 12 days old Preterm (36 weeks gestation male baby with birth weight of 2.6 kg developed respiratory distress with severe cyanosis and desaturation upto 50%. Baby was intubated and started on Prostaglandin 0.05 mic/kg/mt. His saturation improved to 80%. Echocardiogram showed complex cyanotic heart disease, Situs ambiguous, dextrocardia, complete unbalanced AV septal defect, pulmonary atresia , nonconfluent small branch pulmonary arteries supplied by the bilateral patent ductus arteriosus (PDA from right aortic arch and all four pulmonary veins form a confluence and drain into superior vena cava(SVC through vertical vein with no obstruction. Baby was taken up for PDA stenting. descending aortogram showed right aortic arch with vertical tortuous duct to right pulmonary artery (RPA and another short duct with acute angle from left subclavian artery to left pulmonary artery (LPA . Both ducti stented with coronary stents. Vertical vein angiogram showed both lungs drain to a confluence and then to SVC via ascending vertical vein with no obstruction. After stenting lung perfusion improved and the baby was stable and maintained 80% saturation on room air. Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Our case is unique with Heterotaxy, TAPVC, Dextrocardia and double ducti. Eventhough bilateral ductal stenting is technically challenging it is successful through femoral artery approach.

  4. Hemodynamics in stented vertebral artery ostial stenosis based on computational fluid dynamics simulations.

    Science.gov (United States)

    Qiao, Aike; Dai, Xuan; Niu, Jing; Jiao, Liqun

    2016-01-01

    Hemodynamic factors may affect the potential occurrence of in-stent restenosis (ISR) after intervention procedure of vertebral artery ostial stenosis (VAOS). The purpose of the present study is to investigate the influence of stent protrusion length in implantation strategy on the local hemodynamics of the VAOS. CTA images of a 58-year-old female patient with posterior circulation transient ischemic attack were used to perform a 3D reconstruction of the vertebral artery. Five models of the vertebral artery before and after the stent implantation were established. Model 1 was without stent implantation, Model 2-5 was with stent protruding into the subclavian artery for 0, 1, 2, 3 mm, respectively. Computational fluid dynamics simulations based on finite element analysis were employed to mimic the blood flow in arteries and to assess hemodynamic conditions, particularly the blood flow velocity and wall shear stress (WSS). The WSS and the blood flow velocity at the vertebral artery ostium were reduced by 85.33 and 35.36% respectively after stents implantation. The phenomenon of helical flow disappeared. Hemodynamics comparison showed that stent struts that protruded 1 mm into the subclavian artery induced the least decrease in blood speed and WSS. The results suggest that stent implantation can improve the hemodynamics of VAOS, while stent struts that had protruded 1 mm into the subclavian artery would result in less thrombogenesis and neointimal hyperplasia and most likely decrease the risk of ISR.

  5. Subintimal stent placement in patients with long segment occlusion of the iliac artery

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ho Jung; Kim, Young Hwan; Kim, Si Hyung; Ko, Sung Min; Choi, Jin Soo; Lee, Hyun Jin; Kim, Hyung Tae; Jo, Won Hyun [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of)

    2008-01-15

    We evaluated the technical feasibility and clinical efficacy of subintimal stent placement for long segment occlusion of the iliac artery. From March 2003 to February 2007, subintimal stent placement for long segment occlusion of the iliac artery of 24 limbs in 22 patients was analyzed retrospectively. Endovascular access was performed via the ipsilateral femoral artery in 7 cases, via the contralateral femoral artery in 6 cases, via both femoral arteries in 10 cases and via the brachial artery in one case. The SAFARI (subintimal arterial flossing with antegrade-retrograde intervention) technique using a microcatheter was performed to recannalize iliac artery occlusion in three cases. Medical records were reviewed for the collection of follow-up data. The stent patency rate was analyzed by use of the Kaplan-Meier method. Subintimal stent placement was technically successful in 23 of 24 procedures (95.8%). The mean ankle-brachial index (ABI) increased form 0.26 to 0.82. The Fontaine classification was improved after stent placement in all patients. Major complications occurred in four procedures: three distal embolizations and one arterial rupture. All of the complications were successfully treated by endovascular intervention. The primary stent patency rates at 6-months, 1-, 2-and 3-years were 95%, 88%, 88% and 88%, respectively. Subintimal stent placement is a safe and effective treatment for long segment occlusion of the iliac artery.

  6. Incidence of New Ischaemic Brain Lesions After Carotid Artery Stenting with the Micromesh Roadsaver Carotid Artery Stent: A Prospective Single-Centre Study

    Energy Technology Data Exchange (ETDEWEB)

    Ruffino, Maria Antonella, E-mail: mruffino@cittadellasalute.to.it [Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Vascular Radiology Unit, Department of Diagnostic Imaging and Radiotherapy (Italy); Faletti, Riccardo [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Radiology Unit, Department of Surgical Sciences (Italy); Bergamasco, Laura [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Department of Surgical Sciences (Italy); Fonio, Paolo [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Radiology Unit, Department of Surgical Sciences (Italy); Righi, Dorico [Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Vascular Radiology Unit, Department of Diagnostic Imaging and Radiotherapy (Italy)

    2016-11-15

    AimsSeveral randomized trials of patients with carotid stenosis show increased adverse neurological events with stenting versus endarterectomy in the 30-day post-procedure. This study examines the incidence of new ischaemic lesions in patients treated in our centre using the new Roadsaver stent.Methods and resultsBetween September 2015 and January 2016, 23 consecutive patients (age 74.3 ± 7.3 years, 17.4 % female) underwent carotid artery stenting with the Roadsaver stent, a nitinol double-layer micromesh device. A distal protection device was used in all cases. Diffusion-weighted magnetic resonance imaging was performed 24 h before, and 24 h and 30 days after the procedure. The 24-h post-procedure imaging showed 15 new ipsilateral ischaemic lesions in 7 (30.4 %) patients: median volume 0.076 cm{sup 3} (interquartile range 0.065–0.146 cm{sup 3}). All lesions were asymptomatic. The 30-day imaging showed complete resolution of all lesions and no new ischaemic lesions. Follow-up clinical and ultrasound examinations at 30 days and 6 months recorded no adverse cardiac or cerebrovascular events.ConclusionsProtected stenting with micromesh Roadsaver stent showed good safety and efficacy in the treatment of carotid stenosis, with a low incidence of delayed embolic events and new ipsilateral ischaemic brain lesions. These preliminary results are encouraging, but need to be confirmed with larger populations.

  7. Incidence of New Ischaemic Brain Lesions After Carotid Artery Stenting with the Micromesh Roadsaver Carotid Artery Stent: A Prospective Single-Centre Study

    International Nuclear Information System (INIS)

    Ruffino, Maria Antonella; Faletti, Riccardo; Bergamasco, Laura; Fonio, Paolo; Righi, Dorico

    2016-01-01

    AimsSeveral randomized trials of patients with carotid stenosis show increased adverse neurological events with stenting versus endarterectomy in the 30-day post-procedure. This study examines the incidence of new ischaemic lesions in patients treated in our centre using the new Roadsaver stent.Methods and resultsBetween September 2015 and January 2016, 23 consecutive patients (age 74.3 ± 7.3 years, 17.4 % female) underwent carotid artery stenting with the Roadsaver stent, a nitinol double-layer micromesh device. A distal protection device was used in all cases. Diffusion-weighted magnetic resonance imaging was performed 24 h before, and 24 h and 30 days after the procedure. The 24-h post-procedure imaging showed 15 new ipsilateral ischaemic lesions in 7 (30.4 %) patients: median volume 0.076 cm"3 (interquartile range 0.065–0.146 cm"3). All lesions were asymptomatic. The 30-day imaging showed complete resolution of all lesions and no new ischaemic lesions. Follow-up clinical and ultrasound examinations at 30 days and 6 months recorded no adverse cardiac or cerebrovascular events.ConclusionsProtected stenting with micromesh Roadsaver stent showed good safety and efficacy in the treatment of carotid stenosis, with a low incidence of delayed embolic events and new ipsilateral ischaemic brain lesions. These preliminary results are encouraging, but need to be confirmed with larger populations.

  8. Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs.

    Science.gov (United States)

    Holzapfel, Gerhard A; Stadler, Michael; Gasser, Thomas C

    2005-02-01

    Clinical studies have identified factors such as the stent design and the deployment technique that are one cause for the success or failure of angioplasty treatments. In addition, the success rate may also depend on the stenosis type. Hence, for a particular stenotic artery, the optimal intervention can only be identified by studying the influence of factors such as stent type, strut thickness, geometry of the stent cell, and stent-artery radial mismatch with the wall. We propose a methodology that allows a set of stent parameters to be varied, with the aim of evaluating the difference in the mechanical environment within the wall before and after angioplasty with stenting. Novel scalar quantities attempt to characterize the wall changes inform of the contact pressure caused by the stent struts, and the stresses within the individual components of the wall caused by the stent. These quantities are derived numerically and serve as indicators, which allow the determination of the correct size and type of the stent for each individual stenosis. In addition, the luminal change due to angioplasty may be computed as well. The methodology is demonstrated by using a full three-dimensional geometrical model of a postmortem specimen of a human iliac artery with a stenosis using imaging data. To describe the material behavior of the artery, we considered mechanical data of eight different vascular tissues, which formed the stenosis. The constitutive models for the tissue components capture the typical anisotropic, nonlinear and dissipative characteristics under supra-physiological loading conditions. Three-dimensional stent models were parametrized in such a way as to enable new designs to be generated simply with regard to variations in their geometric structure. For the three-dimensional stent-artery interaction we use a contact algorithm based on smooth contact surfaces of at least C-continuity, which prevents numerical problems known from standard facet-based contact

  9. Coronary artery aneurysm after stent implantation: acute and long-term results after percutaneous treatment with a stent graft.

    Science.gov (United States)

    Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna

    2002-03-01

    A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.

  10. Angioplasty and stent placement in the treatment of radiation-induced arterial injury

    International Nuclear Information System (INIS)

    Liu Pengcheng; Pierre, P.; Philippe, O.; Danial, C.; Jean-Paul, B.; Cyril, B.; Jean-Pierre, C.; Denis, K.; Helve, R.; Francis, J.

    1999-01-01

    Objective: Evaluation of therapeutic efficacy and longterm patency of angioplasty and stent for the treatment of radiation induced arterial disease. Methods: PTA was attempted in 18 arterial lesions following irradiation in 14 patients. Thirteen stents were placed in 8 patients to treat occlusion (n = 3), aneurysm (n = 1), residual stenosis (n =2), multiple stenoses (n = 1), and delayed restenosis after previous balloon angioplasty (n = 1). The stents were readily visualized and patency of the stent and the target artery determined with Doppler US and (or) CT in all patients. Results: Interventional procedure was successful in 14 patients of which 8 underwent stent placement for their arterial lesions. Eleven of these patients demonstrated primary patency with relief of clinical symptoms with a mean follow-up of 2 years (range, 8 months -60 months). Clinical improvement was noted for the other patients. Eleven patients underwent PTA once or twice. One patient had PTA four times and three stents were installed, two of which were in the area of the aortic bifurcation, and one in the celiac trunk. another patient also had PTA four times and two stents were placed in the superior mesenteric artery. A stent was implanted in one patient because of PTA induced dissection and occlusion, and the arterial lesion was considered to be cured clinically after a follow-up of 5 years. Conclusions: The results suggested that PTA with single or multiple techniques may be effective immediately in the treatment of arterial lesions caused by radiation and can be considered the first therapeutic option in these cases

  11. Flow Characteristics Near to Stent Strut Configurations on Femoropopliteal Artery

    Science.gov (United States)

    Paisal, Muhammad Sufyan Amir; Fadhil Syed Adnan, Syed; Taib, Ishkrizat; Ismail, Al Emran; Kamil Abdullah, Mohammad; Nordin, Normayati; Seri, Suzairin Md; Darlis, Nofrizalidris

    2017-08-01

    Femoropopiteal artery stenting is a common procedure suggested by medical expert especially for patient who is diagnosed with severe stenosis. Many researchers reported that the growth of stenosis is significantly related to the geometry of stent strut configuration. The different shapes of stent geometry are presenting the different flow pattern and re-circulation in stented femoropopliteal artery. The blood flow characteristics near to the stent geometry are predicted for the possibility of thrombosis and atherosclerosis to be formed as well as increase the growth of stenosis. Thus, this study aims to determine the flow characteristic near to stent strut configuration based on different hemodynamic parameters. Three dimensional models of stent and simplified femoropopliteal artery are modelled using computer aided design (CAD) software. Three different models of stent shapes; hexagon, circle and rectangle are simulated using computational fluid dynamic (CFD) method. Then, parametric study is implemented to predict the performance of stent due to hemodynamic differences. The hemodynamic parameters considered are pressure, velocity, low wall shear stress (WSSlow) and wall shear stress (WSS). From the observation, flow re-circulation has been formed for all simulated stent models which the proximal region shown the severe vortices. However, rectangular shape of stent strut (Type P3) shows the lowest WSSlow and the highest WSS between the range of 4 dyne/cm2 and 70 dyne/cm2. Stent Type P3 also shows the best hemodynamic stent performance as compare to others. In conclusion, Type P3 has a favourable result in hemodynamic stent performance that predicted less probability of thrombosis and atherosclerosis to be formed as well as reduces the growth of restenosis.

  12. Stenting for peripheral artery disease of the lower extremities: an evidence-based analysis.

    Science.gov (United States)

    2010-01-01

    -popliteal, crural and iliac artery stenosis or occlusion), does primary stenting provide immediate success compared to PTA?In individuals with PAD of the lower extremities (superficial femoral artery, infra-popliteal, crural and iliac artery stenosis or occlusion), is primary stenting associated with less complications compared to PTA?In individuals with PAD of the lower extremities (superficial femoral artery, infra-popliteal, crural and iliac artery stenosis or occlusion), does primary stenting compared to PTA reduce the rate of re-intervention?In individuals with PAD of the lower extremities (superficial femoral artery, infra-popliteal, crural and iliac artery stenosis or occlusion) is primary stenting more effective than PTA in improving clinical and hemodynamic success?Are drug eluting stents more effective than bare stents in improving patency, reducing rates of re-interventions or complications? A literature search was performed on February 2, 2010 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, OVID EMBASE, the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA). Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any additional relevant studies not identified through the search. The quality of evidence was assessed as high, moderate, low or very low according to GRADE methodology. English language full-reports from 1950 to January Week 3, 2010Comparative randomized controlled trials (RCTs), systematic reviews and meta-analyses of RCTsProven diagnosis of PAD of the lower extremities in all patients.Adult patients at least 18 years of age.Stent as at least one treatment arm.Patency, re-stenosis, re-intervention, technical success, hemodynamic (ABI) and clinical improvement and complications as at least an outcome. Non-randomized studiesObservational studies (cohort or retrospective studies) and

  13. Short-term safety and efficacy of the biodegradable iron stent in mini-swine coronary arteries

    Institute of Scientific and Technical Information of China (English)

    WU Chao; QIU Hong; HU Xiao-ying; RUAN Ying-mao; TIAN Yi; CHU Yan; XU Xin-lin

    2013-01-01

    Background To overcome the drawbacks of permanent stents,biodegradable stents have been studied in recent years.The bioabsorbable polymer vascular scaffold (BVS) was the first bioabsorbable stent to undergo clinical trials,demonstrating safety and feasibility in the ABSORB studies.Iron can potentially serve as the biomaterial for biodegradable stents.This study aimed to assess the short-term safety and efficacy of a biodegradable iron stent in mini-swine coronary arteries.Methods Eight iron stents and eight cobalt chromium alloy (VISION) control stents were randomly implanted into the LAD and RCA of eight healthy mini-swine,respectively.Two stents of the same metal base were implanted into one animal.At 28 days the animals were sacrificed after coronary angiography,and histopathological examinations were performed.Results Histomorphometric measurements showed that mean neointimal thickness ((0.46±0.17) mm vs.(0.45±0.18)mm,P=0.878),neointimal area ((2.55±0.91) mm2 vs.(3.04±1.15) mm2,P=0.360) and percentage of area stenosis ((44.50±11.40)% vs.(46.00±17.95)%,P=0.845) were not significantly different between the iron stents and VISION stents.There was no inflammation,thrombosis or necrosis in either group.The scanning electron microscopy (SEM) intimal injury scores (0.75±1.04 vs.0.88±0.99,P=0.809) and number of proliferating cell nuclear antigen (PCNA) positive staining cells were not significantly different between the two groups.The percentage of neointimal coverage by SEM examination was numerically higher in iron stents than in VISION stents ((84.38±14.50)% vs.(65.00±22.04)%,P=0.057),but the difference was not statistically significant.Iron staining in the tissue surrounding the iron stents at 28 days was positive and the vascular wall adjacent to the iron stent had a brownish tinge,consistent with iron degradation.No abnormal histopathological changes were detected in coronary arteries or major organs.Conclusions The biodegradable iron stent has

  14. Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation

    International Nuclear Information System (INIS)

    Maintz, David; Juergens, Kai-Uwe; Heindel, Walter; Fischbach, Roman; Wichter, Thomas; Grude, Matthias

    2003-01-01

    The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally obscured in the Wiktor stent, the Wallgraft stent, and the Nir Royal stent. Partial residual of the stent lumen could be visualized in all other utilized stent products (artificial lumen reductions ranged from 62% in the V-Flex stent to 94% in the Bx Velocity stent). Parts of the stent lumen can be visualized in most coronary artery stents; however, detectability of in-stent stenoses remains to be evaluated for each stent type. (orig.)

  15. Stent angioplasty for the treatment of symptomatic stenosis of middle cerebral artery

    International Nuclear Information System (INIS)

    Lu Huisheng; Niu Huiming; Chao Yuanxiang; Li Xiaoning; Wu Dingfeng; Zhang Chenhong; Yang Jie; Zhang Liang

    2010-01-01

    Objective: To investigate the safety and feasibility of endovascular stent angioplasty in treating symptomatic stenosis of middle cerebral artery. Methods: Endovascular angioplasty with coronary stents was performed in 27 patients with symptomatic stenosis of middle cerebral artery. The clinical results were reviewed and analyzed. Results: Of the total 27 patients, successful placement of the coronary stents was achieved in 24. Angiography immediately after the procedure showed that the stenotic degree of the diseased artery was markedly decreased from preoperative (80 ± 19)% to postoperative (8 ±4)%, the improvement was very obvious. Percutaneous transcatheter angioplasty had to be employed in two cases because of the failure of stent placement. A mean follow-up period of 18 months was carried out. During the following up period no transient cerebral ischemia attack occurred in 25 patients and no newly-developed cerebral infarction in region fed by the responsible vessels occurred either.Re-irrigation cerebral hemorrhage was seen in one patient, which occurred three hours after the placement of the stent. In one case the placed stent fell off and immigrated into the siphon of internal carotid artery, and the displaced stent was took out later with a catching apparatus. In another case re-stenosis occurred six months after the stenting. Conclusion: Percutaneous endovascular stent angioplasty is a safe and effective treatment for symptomatic stenosis of middle cerebral artery, although its long-term results need to be further evaluated. (authors)

  16. Primary stenting as emergency therapy in acute basilar artery occlusion

    International Nuclear Information System (INIS)

    Spreer, Joachim; Arnold, Sebastian; Klisch, Joachim; Schumacher, Martin; Els, Thomas; Hetzel, Andreas; Huppertz, Hans-Juergen; Oehm, Eckhardt

    2002-01-01

    In three patients with acute occlusion of the basilar artery intra-arterial fibrinolysis resulted in only partial recanalization and revealed severe stenosis as the underlying cause. Application of micro-stents without previous dilatation resulted in vessel re-opening. Two patients had an excellent clinical outcome. One patient died 10 days after the stroke due to brainstem infarction. Emergency primary stent application may improve the outcome in acute basilar artery occlusion, if intra-arterial thrombolysis fails to re-establish a sufficient flow. (orig.)

  17. Feasibility of Angioplasty and Stenting for Abdominal Aortic Lesions Adjacent to Previously Stented Visceral Artery Lesions in Patients with Takayasu Arteritis

    International Nuclear Information System (INIS)

    Joseph, George; George, Paul V.; Pati, Purendra Kumar; Chandy, Sunil Thomas

    2007-01-01

    Two young female patients with Takayasu arteritis presented with symptomatic long-segment abdominal aortic stenosis in the vicinity of previously deployed celiac and renal artery stents that projected markedly into the narrowed aortic lumen. Crushing or distortion of the visceral artery stents during aortic angioplasty was avoided by performing simultaneous or alternating balloon dilatations in the aorta and in the visceral artery stents. Consequently, the visceral artery stents remained patent and shortened longitudinally, allowing unhindered deployment of Wallstents in the adjacent aorta and abolition of a pressure gradient across the aortic lesions. Access to side branches covered by the Wallstent was obtained without difficulty, enabling the performance of balloon dilatation in multiple side branches and ostial stent deployment in a renal artery. These techniques could increase the scope of endovascular therapy in the treatment of patients with Takayasu arteritis

  18. Treatment of carotid artery aneurysms with covered stents; Aneurysmabehandlung der Arteria carotis interna mit gecoverten Stents

    Energy Technology Data Exchange (ETDEWEB)

    Rohr, A.; Alfke, K.; Doerner, L.; Jansen, O. [UKSH Kiel (Germany). Neurochirurgie Neuroradiologie; Bartsch, T.; Stingele, R. [UKSH Kiel (Germany). Neurologie

    2007-10-15

    Purpose: Evaluation of the use of covered stents in treating pseudoaneurysms of the cervical and intracranial/extradural carotid artery and determination of the periprocedural and short- to mid-term complication rate. Materials and Methods: 8 patients with 9 spontaneous dissecting aneurysms of the cervical carotid artery - 5 of which were symptomatic - plus one patient with ofthalmoplegia due to an aneurysm of the cavernous carotid artery were studied. While the latter was treated with a PTFE-covered balloon-mounted stainless steel stent (Jostent/Graftmaster), a self-expanding PTFE-covered Nitonol Stent (Symbiot) was used in all other cases. Intervention was performed with local anesthesia. Aspirin and Clopidogrel were both used as antiplatelet drugs. Clinical signs and symptoms and vascular imaging with DS, MR, CT angiography and ultrasound were recorded during patient follow-up, with a mean follow-up period of 14.6 months (4 - 30). Results: We were able to treat 8 out of 10 aneurysms (80 %) using covered stents. The aneurysms were immediately occluded and the associated stenoses of the parent vessel were eliminated. No clinically relevant complications occurred during the procedure or in the follow-up interval. In two cases, elongation of the carotid artery prevented the stent from being positioned over the aneurysm neck. These cases were shown to be stable with the use of antiplatelet drugs. Conclusion: Covered stents can be used in the treatment of pseudoaneurysms of the carotid artery as an alternative to long-term antithrombotic medication or surgery. In our study treatment was effective (80 %) and free of complications in the short- and mid-term follow-up. Possible indications, technique and the use of imaging modalities for patient follow-up are discussed. (orig.)

  19. [Successful correction with stent-graft of coronary artery rupture after angioplasty].

    Science.gov (United States)

    Demin, V V

    2003-01-01

    Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.

  20. The use of coronary stent in hepatic artery stenosis after orthotopic liver transplantation

    International Nuclear Information System (INIS)

    Huang Mingsheng; Shan Hong; Jiang Zaibo; Li Zhengran; Zhu Kangshun; Guan Shouhai; Qian Jiesheng; Chen Guihua; Lu Minqiang; Yang Yang

    2006-01-01

    Purpose: This retrospective study was undertaken to evaluate the effectiveness of coronary stent placement in hepatic artery stenosis after orthotopic liver transplantation (OLT). Materials and methods: Of 430 consecutive adult orthotopic liver transplant recipients between November 2003 and September 2005, 17 had hepatic artery stenosis (HAS). Fourteen of them underwent coronary stent placement in the HAS. The technical results, complications, hepatic artery patency and clinical outcome were reviewed. Results: Technical and immediate success was 100%. After a mean follow-up of 159.4 days (range, 9-375 days), all patients obtained patent hepatic arteries except 2 patients occurred hepatic artery restenoses at 26 and 45 days after stent placement, respectively. Kaplan-Meier curve of patency showed cumulated stent patency at 3, 6, and 12 months of 78%, 58% and 45%, respectively. During the follow-up, 8 patients survived, 5 died of septic multiple-organ failure, 1 received retransplantation because of refractory biliary infection. Hepatic artery dissection induced by a guiding catheter occurred in one patient and was successfully treated with a coronary stent. Conclusion: Hepatic artery stenosis after OLT can be successfully treated with coronary stent placement with low complication rate and an acceptable 1-year hepatic artery patency rate

  1. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-01-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-termmorbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD. PMID:29470746

  2. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance.

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-05-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-term morbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD.

  3. Treatment of splenic artery aneurysm with double overlapping bare stents: case report

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Han, Young Min; Jin, Gong Yong

    2004-01-01

    The traditional treatment of splenic artery aneurysm (SAA) is generally surgery and/or transcatheter arterial embolization, but recently, the treatment of SAA using a stent graft has been reported. However, the acute angle of the celiac axis, as well as the tortuous path of the splenic artery makes the use of stent graft difficult for treatment of aneurysma. We report here a case of SAA treated with the technique of double overlapping metallic stents

  4. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    Energy Technology Data Exchange (ETDEWEB)

    Mourand, Isabelle [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France); Hopital Gui de Chauliac, Department of Neurology, Service de Neurologie, Montpellier, Cedex 5 (France); Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain [Hopital Gui de Chauliac, Department of Neuroradiology, CHU Montpellier, Montpellier, Cedex 5 (France); Thouvenot, Eric [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France)

    2010-02-15

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS {<=}1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  5. Time-dependent 3D simulations of the hemodynamics in a stented coronary artery

    International Nuclear Information System (INIS)

    Faik, Isam; Mongrain, Rosaire; Leask, Richard L; Rodes-Cabau, Josep; Larose, Eric; Bertrand, Olivier

    2007-01-01

    Stenting is becoming the major interventional cardiology procedure worldwide. However restenosis remains a major limitation to the effectiveness of stents. Alterations to the local hemodynamics in the stented segment of the artery could be a potential factor in the development of in-stent restenosis. The characterization of wall shear stress and of blood flow patterns in a stented artery is therefore necessary for a good understanding of the role of hemodynamics in the development of in-stent restenosis. We have used a time-dependent 3D numerical model of a stented coronary artery to study the characteristics of the blood flow and the shear stress distribution. Our results show that the presence of the stent produces significant secondary flow that is limited to an annulus in the near wall region. Low shear stress zones were localized in the vicinity of the struts while the tips of the struts exhibited high values of shear stress. These results support the hypothesis that local hemodynamics may affect the development of in-stent restenosis and could influence the choice of stent geometries for future stent designs

  6. Randomized Comparison of Ridaforolimus- and Zotarolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: Primary Results From the BIONICS Trial (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis).

    Science.gov (United States)

    Kandzari, David E; Smits, Pieter C; Love, Michael P; Ben-Yehuda, Ori; Banai, Shmuel; Robinson, Simon D; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y; Balcells, Mercedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R; Leon, Martin B; Stone, Gregg W

    2017-10-03

    The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, P noninferiority =0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P =0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm ( P noninferiority =0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively ( P noninferiority =0.01). In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. URL: http

  7. Experimental research of covered stent implanted in canine hepatic artery

    International Nuclear Information System (INIS)

    Zhou Bing; Liu Linxiang; Li Minghua; Wang Yongli; Cheng Yongde

    2007-01-01

    Objective: To evaluate the feasibility of success rate of implantation, post-procedure stenosis rate, apposition ability and endothelialization level, etc. for implantation with balloon-expandable covered stent in canine hepatic artery. Methods: 8 adult canines were implanted with balloon-expendable stents covered by expandable poly Teflon ester membrane (e-PTFEM). Follow-up DSA was performed immediately, 2, 4 and 12 wk after the procedure. The canines were sacrificed for histopathologic examination and statistical analysis with correlation of implantation manenvor and angiographic manifestations. Results: 8 cases were all implanted with the covered stents in proper hepatic artery/right hepatic artery successfully; showing good apposition ability and non-opacification of the separated branches. 2 cases showed intraluminal obvious stenosis( > 50%)of the stent at 2 weeks follow-up, so did 3 cases at 12 weeks follow-up, and the total stenosis rate was 37.5% and 5 cases manifested full endothelialization (3 different locations of the sample all manifested full endothelialization), 3 cased manifested partial endothelialization (at least 1 location of the sample didn't show full endothelialization), and the two terminal parts were easier to get endothelialization than the central part. Before and after the stent implantation, hepatic function of all cases didn't demonstrate any obvious changes. Conclusions: Balloon-expandable covered stent can be implanted in canine hepatic artery. successfully, with good apposition ability, full endothelialization, and no influence on hepatic function. (authors)

  8. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    International Nuclear Information System (INIS)

    Mourand, Isabelle; Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain; Thouvenot, Eric

    2010-01-01

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS ≤1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  9. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  10. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    International Nuclear Information System (INIS)

    Sun, Zhonghua; Chaichana, Thanapong

    2010-01-01

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair

  11. Carotid artery stenting: Rationale, technique, and current concepts

    International Nuclear Information System (INIS)

    Yilmaz, Hasan; Pereira, Vitor Mendes; Narata, Ana-Paula; Sztajzel, Roman; Lovblad, Karl-Olof

    2010-01-01

    Carotid stenosis is a major risk factor for stroke. With the aging of the general population and the availability of non-invasive vascular imaging studies, the diagnosis of a carotid plaque is commonly made in medical practice. Asymptomatic and symptomatic carotid stenoses need to be considered separately because their natural history is different. Two large randomized controlled trials (RCTs) showed the effectiveness of carotid endarterectomy (CEA) in preventing ipsilateral ischemic events in patients with symptomatic severe stenosis. The benefit of surgery is much less for moderate stenosis and harmful in patients with stenosis less than 50%. Surgery has a marginal benefit in patients with asymptomatic stenosis. Improvements in medical treatment must be taken into consideration when interpreting the results of these previous trials which compared surgery against medical treatment available at the time the trials were conducted. Carotid artery stenting (CAS) might avoid the risks associated with surgery, including cranial nerve palsy, myocardial infarction, or pulmonary embolism. Therefore and additionally to well-established indications of CAS, this endovascular approach might be a valid alternative particularly in patients at high surgical risk. However, trials of endovascular treatment of carotid stenosis have failed to provide enough evidence to justify routine CAS as an alternative to CEA in patients suitable for surgery. More data from ongoing randomized trials of CEA versus CAS will be soon available. These results will help determining the role of CAS in the management of patients with carotid artery stenosis.

  12. Factors that affect mass transport from drug eluting stents into the artery wall

    Directory of Open Access Journals (Sweden)

    Walsh Michael T

    2010-03-01

    Full Text Available Abstract Coronary artery disease can be treated by implanting a stent into the blocked region of an artery, thus enabling blood perfusion to distal vessels. Minimally invasive procedures of this nature often result in damage to the arterial tissue culminating in the re-blocking of the vessel. In an effort to alleviate this phenomenon, known as restenosis, drug eluting stents were developed. They are similar in composition to a bare metal stent but encompass a coating with therapeutic agents designed to reduce the overly aggressive healing response that contributes to restenosis. There are many variables that can influence the effectiveness of these therapeutic drugs being transported from the stent coating to and within the artery wall, many of which have been analysed and documented by researchers. However, the physical deformation of the artery substructure due to stent expansion, and its influence on a drugs ability to diffuse evenly within the artery wall have been lacking in published work to date. The paper highlights previous approaches adopted by researchers and proposes the addition of porous artery wall deformation to increase model accuracy.

  13. Mechanical Recanalization of Cerebral Artery Embolic Occlusion Using a Self-Expanding Stent: Experimental Analysis in Canine Model

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul

    2011-01-01

    To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 ± 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.

  14. Mechanical Recanalization of Cerebral Artery Embolic Occlusion Using a Self-Expanding Stent: Experimental Analysis in Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2011-07-15

    To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 {+-} 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.

  15. Use of a wire extender during neuroprotected vertebral artery angioplasty and stenting.

    Science.gov (United States)

    Lesley, Walter S; Kumar, Ravi; Rangaswamy, Rajesh

    2010-09-01

    The off-label use of an extender wire during vertebral artery stenting and angioplasty with or with neuroprotection has not been previously reported. Retrospective, single-patient, technical report. After monorail balloon angioplasty was performed on a proximal left vertebral artery stenosis, the 190 cm long Accunet neuroprotection filter device was not long enough for delivery of an over-the-wire stent. After mating a 145 cm long, 0.014 inch extension wire to the filter device, a balloon-mounted Liberté stent was implanted with good angiographic and clinical results. The off-label use of an extender wire permits successful over-the-wire stenting on a monorail neuroprotection device for vertebral artery endosurgery.

  16. Risk factors for in-stent restenosis of vertebral artery origin after stent implantation: a Meta-analysis

    Directory of Open Access Journals (Sweden)

    Fang-fang HAO

    2018-01-01

    Full Text Available Objective To systematically review the risk factors for in-stent restenosis (ISR of vertebral artery origin after sent implantation to provide theoretical foundation for clinical prevention and treatment. Methods Taking vertebral artery, vertebrobasilar insufficiency, stents, drug-eluting stents, self expandable metallic stents in English and Chinese as key words, retrospective clinical studies about risk factors for ISR of vertebral artery origin were searched by using PubMed, EMBASE/SCOPUS, Cochrane Library, China Biology Medicine (CBM, China National Knowledge Infrastructure (CNKI, Wanfang Data and VIP database from January 1, 1966 to March 30, 2017. Quality assessment and Meta-analysis were made by using Newcastle-Ottawa Scale (NOS and Stata 12.0 software. Results The research enrolled 3468 articles in all, from which 11 studies were chosen after excluding duplicates and those not meeting the inclusion criteria. A total number of 1352 patients were divided into ISR group (N = 440 and non-ISR group (N = 912. The ISR incidence rate of smokers was significantly higher than non-smokers (OR = 2.179, 95%CI: 1.373-3.458; P = 0.001. The differences of bare metal stents (BMS utilization rate (OR = 2.072, 95% CI: 1.560-2.753; P = 0.000 and drug-eluting stents (DES utilization rate (OR = 0.483, 95% CI: 0.363-0.641; P = 0.000 between ISR group and non-ISR group were statistically significant. Conclusions Smoking and using BMS are risk factors for ISR of vertebral artery origin, and using DES is protective factor. Due to limited study quality, more high-quality studies are needed to verify this conclusion. DOI: 10.3969/j.issn.1672-6731.2017.12.004

  17. Self-Expandable Stent Placement in Infrapopliteal Arteries After Unsuccessful Angioplasty Failure: One-Year Follow-up

    International Nuclear Information System (INIS)

    Peregrin, J. H.; Smirova, S.; Koznar, B.; Novotny, J.; Kovac, J.; Lastovickova, J.; Skibova, J.

    2008-01-01

    The purpose of this prospective study was to evaluate whether stent placement in infrapopliteal arteries is helpful in failed percutaneous transluminal angioplasty (PTA). Infrapopliteal PTA was performed in 70 arteries of 66 patients with chronic critical lower limb ischemia. The group comprised 55 males and 11 females, with an average age of 63.4 (range, 42-82) years. Diabetes mellitus was present in 92.4% of patients. Only the palpable anterior tibial and posterior tibial arteries were evaluated. Stents (Xpert stent; Abbot Vascular, Redwood City, CA, USA) were placed in 16 arteries where PTA was not successful (the failure was defined as residual stenosis >30% after PTA). In 54 arteries simple PTA was performed and was technically successful. Twenty-four nondilated arteries with no significant stenosis served as a comparison group. The 12-month patency rate was evaluated according to a combination of palpation and Doppler ultrasound. In all cases stent placement restored the flow in the artery immediately after unsuccessful PTA. Twelve-month follow-up showed a patency rate of 82% in the PTA group, 78% in the stent group, and 69% in the comparison group. We conclude that stent placement in the case of unsuccessful infrapopliteal PTA changed technical failure to success and restored flow in the dilated artery. At 12-month follow-up the patency rate of infrapopliteal arteries stented for PTA failure did not differ significantly either from nonstented arteries with an optimal PTA result or from a comparison group of nonintervened arteries.

  18. A Comparison of Stent Implant versus Medical Treatment for Severe Symptomatic Intracranial Stenosis: A Controlled Clinical Trial

    Directory of Open Access Journals (Sweden)

    Rezao Mohammadian

    2012-11-01

    Full Text Available Background: Atherosclerotic stenosis of the major intracranial arteries is the most common cause of ischemic stroke. There are limited treatments for severe intracranial stenosis, and stent placement versus medical treatment remains controversial. The aim of this study was to compare functional outcomes of these two modalities in patients with severe symptomatic intracranial stenosis. Methods: At a single center, between 2008 and 2011, patients with angiographically demonstrated severe (70–90% symptomatic intracranial atherosclerosis were divided into two groups: group A, which received only medical treatment, and group B, which underwent endovascular stent implant treatment. The severity and location of the stenosis was determined by digital subtraction angiography and the Warfarin-Aspirin Symptomatic Intracranial Disease (WASID trial criteria in all patients. The exclusion criteria were: specific causes other than atherosclerosis, such as artery dissection, fibromuscular dysplasia, vasculitis, radiation and intracranial hemorrhage, focal neurological deficit that did not correlate to internal carotid artery or middle cerebral artery stenosis. All procedures were done under light anesthesia. Technical success was defined as the reduction of stenosis to Results: Overall, 63 patients (29 in group A and 34 in group B were evaluated and followed for a mean period of 15.22 months (range 6–25. The technical success rate was 97% in a total of 34 stents in 34 patients. There was no difference between the early (within 30 days adverse event rates of the two groups. The median follow-up duration for the stent implant patients was 15 months (range 6–25, and for the medically treated cohort it was 14 months (range 8–25. The re-stenosis rate was 5.8% and the total number of late (>30 days adverse events, including stroke, myocardial infarction and death, was 1 (2.9% and 6 (20.7% in the stent implant and medical groups, respectively (p = 0.042. The

  19. Study on the effect of location of intracranial arterial stenosis on the safety of stenting

    Directory of Open Access Journals (Sweden)

    Yu-jie SUN

    2017-11-01

    Full Text Available Objective To investigate the effect of location of intracranial arterial stenosis on the safety of intracranial stenting. Methods A total of 73 patients with symptomatic intracranial atherosclerotic stenosis (ICAS were divided into intracranial internal carotid artery (IICA, N = 18, middle cerebral artery (MCA-M1 segment (MCA-M1, N = 11, intracranial vertebral artery (IVA, N = 27 and basilar artery (BA, N = 17. All of them underwent intracranial stenting. The improvement of intracranial arterial stenosis, cerebrovascular complications including perforating events, artery dissection, in-stent thrombosis, distal stent arterial embolism and cerebral hyperperfusion, and neurological complications including transient ischemic attack (TIA, ischemic stroke and intracranial hemorrhage were recorded. Modified Rankin Scale (mRS was used to evaluate the prognosis 30 d after operation. Results A total of 73 stents were implanted in 73 patients (35 Apollo balloon-expandable stents and 38 Wingspan self-expandable stents. Among them, 10 cases (10/18 were treated with Apollo stents and 8 cases (8/18 with Wingspan stents in IICA group, 5 cases (5/11 were treated with Apollo stents and 6 cases (6/11 with Wingspan stents in MCA-M1 group, 16 cases (59.26%, 16/27 were treated with Apollo stents and 11 cases (40.74%, 11/27 with Wingspan stents in IVA group, and 4 cases (4/17 were treated with Apollo stents and 13 cases (13/17 with Wingspan stents in BA group. No significant difference was seen in stent type among 4 groups (χ2 = 7.422, P = 0.201. The stenosis rate of IICA group after treatment [(10.94 ± 1.99%] was significantly improved than before treatment [(90.89 ± 7.71%; t = 69.545, P = 0.000]. The stenosis rate of MCA-M1 group after treatment [(10.37 ± 2.14%] was significantly improved than before treatment [(87.64 ± 9.46%; t = 26.000, P = 0.000]. The stenosis rate of IVA group after treatment [(11.02 ± 1.99% ] was significantly improved than before

  20. Current global status of carotid artery stent placement.

    Science.gov (United States)

    Wholey, M H; Wholey, M; Bergeron, P; Diethrich, E B; Henry, M; Laborde, J C; Mathias, K; Myla, S; Roubin, G S; Shawl, F; Theron, J G; Yadav, J S; Dorros, G; Guimaraens, J; Higashida, R; Kumar, V; Leon, M; Lim, M; Londero, H; Mesa, J; Ramee, S; Rodriguez, A; Rosenfield, K; Teitelbaum, G; Vozzi, C

    1998-05-01

    Our purpose was to review the current status of carotid artery stent placement throughout the world. Surveys were sent to major interventional centers in Europe, North and South America, and Asia. Information from peer-reviewed journals was also included and supplemented the survey. The survey asked various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. Of the centers which were sent surveys, 24 responded. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 2,048 cases, with a technical success of 98.6%. Complications that occurred during carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 63 minor strokes, with a rate of occurrence of 3.08%. The total number of major strokes was 27, for a rate of 1.32%. There were 28 deaths within a 30-day postprocedure period, resulting in a mortality rate of 1.37%. Restenosis rates of carotid stenting have been 4.80% at 6 mo. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative to vascular surgery, especially for patients that are at high risk for standard carotid endarterectomy. The periprocedural risks for major and minor strokes and death are generally acceptable at this early stage of development.

  1. Randomized Comparison of Paclitaxel-Eluting Balloon and Stenting Versus Plain Balloon Plus Stenting Versus Directional Atherectomy for Femoral Artery Disease (ISAR-STATH).

    Science.gov (United States)

    Ott, Ilka; Cassese, Salvatore; Groha, Philipp; Steppich, Birgit; Hadamitzky, Martin; Ibrahim, Tareq; Kufner, Sebastian; Dewitz, Karl; Hiendlmayer, Regina; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan; Fusaro, Massimiliano

    2017-06-06

    Atherosclerosis in the superficial femoral artery is common in patients suffering from peripheral artery disease. Paclitaxel-eluting balloon (PEB) angioplasty, stenting, and directional atherectomy (DA) have provided new options for the treatment of superficial femoral artery disease; however, the comparative efficacy of these interventional strategies remains uncertain. One hundred and fifty-five patients with symptomatic peripheral artery disease due to de novo superficial femoral artery stenotic or occlusive lesions were randomized to treatment with plain balloon angioplasty (BA) followed by PEB angioplasty and stenting (n=48), BA and stenting (n=52), or DA with distal protection and bailout stenting (n=55). The primary end point of the study was percentage diameter stenosis after 6 months measured by angiography. Other end points included target lesion revascularization, thrombosis, ipsilateral amputation, binary restenosis, and all-cause mortality at 6 and 24 months. Baseline and lesion characteristics were comparable in all groups with a mean lesion length of 65.9±46.8 mm and 56% total occlusions. At 6 months angiography, the percent diameter stenosis was significantly lower in patients treated by PEB angioplasty and stenting (34±31%) as compared with BA angioplasty and stenting (56±29%, P =0.009) or DA (55±29%, P =0.007). Similarly, binary restenosis was significantly lower after treatment with PEB and stenting as compared with BA and stenting or DA. Clinical follow-up at 24 months revealed a lower risk for target lesion revascularization after PEB angioplasty and stenting as compared with BA and stenting or DA. We found no difference in terms of target lesion thrombosis and mortality among groups, and no patient underwent amputation. Treatment of de novo superficial femoral artery lesions with PEB angioplasty and stenting is superior to BA angioplasty and stenting or DA in terms of angiographic diameter stenosis at 6 months and target lesion

  2. Functional effects of renal artery stent placement on treated and contralateral kidneys.

    NARCIS (Netherlands)

    Leertouwer, T.C.; Derkx, F.H.M.; Pattynama, P.M.; Deinum, J.; Dijk, L.C. van; Schalekamp, M.A.D.H.

    2002-01-01

    BACKGROUND: This study examined the effects of stent placement for renal artery stenosis on the function of treated and contralateral kidneys. METHODS: Eighteen patients who underwent stent placement for unilateral renal artery stenosis presenting with hypertension and/or renal failure were studied

  3. Clinical observation of intraluminal stent angioplasty in the treatment of renal arterial stenoses

    International Nuclear Information System (INIS)

    Lu Yanwen; Zhang Jian; Huang Xianglong

    2002-01-01

    Objective: To evaluate the clinical application of intraluminal stent angioplasty (PTRAS) in the treatment of renal arterial stenoses. Methods: A retrospective study was done in 28 patients with renal arterial stenoses. Primary renal artery stenting was performed in 28 consecutive patients (36 renal arteries). Blood pressure, serum creating, the number of anti-hypertensive medications were recorded at 1, 6, 12 month post stent angioplasty respectively. Arterial angiography was also taken 1 year later to evaluate the incidence of restenosis. Results: Technical success rate was 100% achieving in all patients without serious complications. Primary successful patently rate reached 82% (renal artery 86%), secondary successful rate was 89% (renal artery 90%). Systolic and diastolic blood pressure were reduced significantly (P<0.01) at 1,6,12 month after stent angioplasty comparing with baseline and clinical improvement (cured + improved) of hypertension reached 100%, 92.9%, 89.3% respectively. There were no significant differences between serum creatine level and the number of anti-hypertensive medications before and after stent angioplasty. One year later, 14.3% of all patients showed improvement of renal function, 64.3% remained in stabilization and 21.4% fell into deterioration. Angiographic restenosis was found in 3 cases one year after stent angioplasty. Complications included 1 hematoma at puncture site and 3 transient azotaemia. Conclusions: PTRAS can be performed safely with high technical success and beneficial to the majority of patients with hypertension or renal insufficiency and therefore it should be the first choice in treating renal arterial stenoses

  4. Combined Arterial Infusion and Stent Implantation Compared with Metal Stent Alone in Treatment of Malignant Gastroduodenal Obstruction

    International Nuclear Information System (INIS)

    Wang Zhongmin; Chen Kemin; Gong Ju; Zheng Yunfeng; Wang Tianxiang

    2009-01-01

    Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival time between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4

  5. Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty

    International Nuclear Information System (INIS)

    Tepe, Gunnar; Heller, Stephan; Wiskirchen, Jakub; Fischmann, Arne; Claussen, Claus D.; Zeller, Thomas; Coerper, Stephan; Beckert, Stefan; Balletshofer, Bernd

    2007-01-01

    The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible in all cases. No complications occurred. After the stent implantation, all primarily unsuccessful interventions could be transformed into successful procedures with no residual stenosis >30% in any case. After 6 ± 2 months, two of the 18 patients died, and 14 of the 16 remaining patients improved clinically. At follow-up, the patency could be assessed in 14 stented arteries. Three stents were occluded, one stent showed some neointimal hyperplasia (50-70% restenosis), the remaining ten stents showed no restenosis (0-30%). The use of self-expanding nitinol stents in tibioperoneal and popliteal arteries is a safe and feasible option for the treatment of unsuccessful PTA. The 6-months patency is high. (orig.)

  6. Enterprise stent for waffle-cone stent-assisted coil embolization of large wide-necked arterial bifurcation aneurysms.

    Science.gov (United States)

    Padalino, David J; Singla, Amit; Jacobsen, Walter; Deshaies, Eric M

    2013-01-01

    Large wide-necked arterial bifurcation aneurysms present a unique challenge for endovascular coil embolization treatment. One technique described in the literature deploys a Neuroform stent into the neck of the aneurysm in the shape of a waffle-cone, thereby acting as a scaffold for the coil mass. This case series presents four patients with large wide-necked bifurcation aneurysms treated with the closed-cell Enterprise stent using the waffle-cone technique. Four patients (59 ± 18 years of age) with large wide-necked arterial bifurcation aneurysms (three basilar apex and one MCA bifurcation) were treated with the waffle-cone technique using the Enterprise stent as a supporting device for stent-assisted coil embolization. Three of the patients presented with aneurysmal subarachnoid hemorrhage (Hunt-Hess 2-3; Fisher Grade 3-4). There was no procedural morbidity or mortality associated with treatment itself. One aneurysm was completely obliterated, and three had small residual necks. One patient developed an area of PCA infarct and visual field cut one month after the procedure and required recoiling of the residual neck. The flared ends of the Enterprise stent remodeled the aneurysm neck by conforming to the shape of the neck without any technical difficulty, resulting in a stable scaffold holding the coils into the aneurysm. The closed cell construction, flexibility, and flared ends of the Enterprise stent allow it to conform to the waffle-cone configuration and provide a stable scaffold for coil embolization of large wide-necked arterial bifurcation aneurysms. We have had excellent initial results using the Enterprise stent with the waffle-cone technique. However, this technique is higher risk than standard treatment methods and therefore should be reserved for large wide-necked bifurcation aneurysms where Y stenting is needed, but not possible, and surgical clip ligation is not an option.

  7. Relationship between the Direction of Ophthalmic Artery Blood Flow and Ocular Microcirculation before and after Carotid Artery Stenting.

    Science.gov (United States)

    Ishii, Masashi; Hayashi, Morito; Yagi, Fumihiko; Sato, Kenichiro; Tomita, Goji; Iwabuchi, Satoshi

    2016-01-01

    When internal carotid artery stenosis is accompanied by ocular ischemic syndrome, intervention is recommended to prevent irreversible visual loss. In this study, we used laser speckle flowgraphy to measure the ocular microcirculation in the optic nerve head before and after carotid artery stenting (CAS) of 40 advanced internal carotid stenosis lesions from 37 patients. The aim was to investigate the relationship between ocular microcirculation and the direction of ophthalmic artery blood flow obtained by angiography. We found that there was a significant increase in blood flow after CAS ( P = 0.003). Peak systolic velocity as an indicator of the rate of stenosis was also significantly higher in the group with retrograde/undetected flow of the ophthalmic artery than in the group with antegrade flow ( P = 0.002). In all cases where retrograde flow of the ophthalmic artery was observed before stenting, the flow changed to antegrade after stenting. Through the use of laser speckle flowgraphy, this study found that CAS can improve ocular microcirculation. Furthermore, while patients displaying retrograde flow of the ophthalmic artery before stenting have a poor prognosis, CAS corrected the flow to antegrade, suggesting that visual loss can be prevented by improving the ocular microcirculation.

  8. Assessment of coronary artery stent patency by electron-beam CT

    International Nuclear Information System (INIS)

    Knollmann, Friedrich D.; Felix, Roland; Moeller, Joerg; Gebert, Axel; Bethge, Christian

    2004-01-01

    Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)

  9. Assessment of coronary artery stent patency by electron-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Knollmann, Friedrich D.; Felix, Roland [Department of Radiology, Charite, Campus Virchow-Klinikum, Humboldt-University, Augustenburger Platz 1, 13353, Berlin (Germany); Moeller, Joerg; Gebert, Axel; Bethge, Christian [Department of Cardiology, Juedisches Krankenhaus, Berlin (Germany)

    2004-08-01

    Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)

  10. Low-profile stent placement with the monorail technique for treatment of renal artery stenosis: midterm results of a prospective trial.

    Science.gov (United States)

    Müller-Hülsbeck, Stefan; Frahm, Christian; Behm, Charlotte; Schäfer, Phillip Jobst; Bolte, Hendrik; Heller, Martin; Jahnke, Thomas

    2005-07-01

    To determine feasibility, safety, and midterm patency of a monorail balloon stent device for the treatment of renal artery stenosis (RAS). During a period of 30 months, 47 patients (with severe hypertension, n=45; renal insufficiency, n=20) with 50 cases of RAS and indications for stent implantation (calcified ostial lesion, n=41; insufficient percutaneous transluminal angioplasty, n=6; dissection, n=3) were enrolled into the prospective evaluation. After predilation, 59 stents (Rx-Herculink 4 mm, n=2; 5 mm, n=19; 6 mm, n=35; 7 mm, n=3) were implanted under manometer control with use of the long-sheath technique (5 F; 6 F for 7-mm stents) via a femoral (n=44) or transbrachial approach (n=6). Parameters of hypertension and renal insufficiency were determined before and after the procedure and for a maximum of 18 months. Restenosis rate was determined with color duplex ultrasonography. Renal artery stent placement (mean diameter, 5.7 mm; mean length, 16 mm) was technically successful in all cases (100%). Mean blood pressure and serum creatinine level decreased from 177/93 mm Hg to 145/78 mm Hg and from 1.8 mg/dL to 1.5 mg/dL, respectively. Within 48 hours after the implantation, acute occlusions occurred in two patients, supposedly triggered by cholesterol embolization. Primary and primary assisted patency rates were 87% and 92% at 6 months and 75% and 84% at 18 months. Renal artery stent placement with the rapid-exchange monorail system is a safe procedure with promising patency rates. In combination with the long-sheath technique, adequate control of stent deployment is guaranteed during the entire intervention. The low profile of the device facilitates the use of small sheaths (5 F) to minimize access-site complications.

  11. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    BACKGROUND: In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery...... disease who were receiving routine clinical care with no direct follow-up. METHODS: We did a single-blind, all-comer superiority trial in adult patients with chronic stable coronary artery disease or acute coronary syndromes, and at least one target lesion. Patients were treated at one of five...... Danish administrative and health-care registries. The primary endpoint was a composite of major adverse cardiac events within 9 months: cardiac death, myocardial infarction, and target vessel revascularisation. Intention-to-treat analyses were done at 9-month and 18-month follow-up. This trial...

  12. The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

    Directory of Open Access Journals (Sweden)

    Hiroshi Fujita

    2014-12-01

    Full Text Available Background: Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. Aim: We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. Methods: Sirolimus-eluting stents were implanted in 88 lesions and bare metal stents were implanted in 43 lesions. We compared stenting strategy, major adverse cardiac events, and angiographic results between sirolimus-eluting stent and bare metal stent groups. Results: Stent diameter was smaller and stent length was longer in the sirolimus-eluting stent group than in the bare metal stent group in our routine practices. There was no significant between-group difference in late diameter loss. Rates of angiographic restenosis and target lesion revascularization were significantly higher in the sirolimus-eluting stent group than in the bare metal stent group. Although stent length was significantly longer and stent diameter was smaller in the sirolimus-eluting stent group, sirolimus-eluting stents did not improve the subsequent clinical and angiographic results compared with bare metal stents in dialysis patients. Conclusion: In dialysis patients, a longer length and/or smaller diameter sirolimus-eluting stent implantation was associated with high rates of restenosis and target lesion revascularization compared with bare metal stents.

  13. Impact on outcome of different types of carotid stent: results from the European Registry of Carotid Artery Stenting.

    Science.gov (United States)

    Stabile, Eugenio; Giugliano, Giuseppe; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitrios; Sannino, Anna; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Rubino, Paolo; Esposito, Giovanni; Tesorio, Tullio

    2016-06-12

    Conflicting data exist on the impact on outcome of the use of different stent types during carotid artery stenting (CAS). The aim of this study was to evaluate clinical outcomes according to different carotid stent design among the population of the European Registry of Carotid Artery Stenting (ERCAS). The present study was conducted in 1,604 patients who underwent neuroprotected CAS in ERCAS. All types of commercially available carotid stent were used. Open-cell design stents were classified according to free cell area into 7.5 mm2. A total of 713 closed-cell, 456 hybrid-cell, 238 7.5 mm2 open-cell stents were implanted. Overall, the 30-day stroke and death rate was 1.37%. At 30 days, 19 strokes occurred (1.18%): eight in the group of patients treated with a closed-cell (1.12%), two in those with a hybrid-cell (0.44%), three in those with a 7.5 mm2 open-cell stent (3.05%) (p=0.045). Data of the present study suggest that, in the setting of neuroprotected CAS performed in high-volume centres by properly trained operators, the use of an open-cell design stent with a free cell area >7.5 mm2 may be associated with an increased 30-day stroke risk.

  14. Neuropsychological outcome after percutaneous coronary intervention or coronary artery bypass grafting: results from the Stent or Surgery (SoS) Trial.

    Science.gov (United States)

    Währborg, Peter; Booth, Jean E; Clayton, Tim; Nugara, Fiona; Pepper, John; Weintraub, William S; Sigwart, Ulrich; Stables, Rod H

    2004-11-30

    Coronary artery bypass surgery (CABG) has been associated with a range of neurological and neuropsychological complications from stroke to cognitive problems such as memory and problem solving disturbance. However, little is known about the impact of percutaneous coronary intervention (PCI) on neuropsychological outcome. In the Stent or Surgery Trial (SoS), 988 patients were randomized in equal proportions between PCI supported by stent implantation and CABG. As a substudy of this trial, we undertook an evaluation of neurological and neuropsychological outcomes after intervention. A clinical examination and neuropsychological assessment consisting of 5 tests (Digit Span Forwards and Backwards, Visual Reproduction, Bourdon, and Block Design) were performed at baseline and 6 and 12 months after the procedure. A total of 145 patients were included in the substudy analysis: 77 in the PCI group and 68 in the CABG group. One patient in the PCI arm had a stroke. There was no significant difference between treatment groups at 6 and 12 months for any of the 5 tests. The mean change from baseline was also similar in both groups. We were not able to demonstrate an important and significant difference in neuropsychological outcome in patients treated with different revascularization strategies. This important finding needs to be examined in further research.

  15. Feasibility and Safety of Transradial Arterial Approach for Simultaneous Right and Left Vertebral Artery Angiographic Studies and Stenting

    International Nuclear Information System (INIS)

    Yip, H.-K.; Youssef, Ali A.; Chang, W.-N.; Lu, C.-H.; Yang, C.-H.; Chen, S.-M.; Wu, C.-J.

    2007-01-01

    Objectives. This study investigated whether the transradial artery (TRA) approach using a 6-French (F) Kimny guiding catheter for right vertebral artery (VA) angiographic study and stenting is safe and effective for patients with significant VA stenosis. Background. The TRA approach is commonly performed worldwide for both diagnostic cardiac catheterization and catheter-based coronary intervention. However, to our knowledge, the safety and feasibility of left and right VA angiographic study and stenting, in the same procedure, using the TRA approach for patients with brain ischemia have not been reported. Methods. The study included 24 consecutive patients (22 male, 2 female; age, 63-78 years). Indications for VA angiographic study and stenting were (1) prior stroke or symptoms related to vertebrobasilar ischemia and (2) an asymptomatic but vertebral angiographic finding of severe stenosis (>70%). A combination of the ipsilateral and retrograde-engagement technique, which involved a looping 6-F Kimny guiding catheter, was utilized for VA angiographic study. For VA stenting, an ipsilateral TRA approach with either a Kimny guiding catheter or a left internal mammary artery guiding catheter was utilized in 22 patients and retrograde-engagement technique in 2 patients. Results. A technically successful procedure was achieved in all patients, including left VA stenting in 15 patients and right VA stenting in 9 patients. The mean time for stenting (from engagement to stent deployment) was 12.7 min. There were no vascular complications or mortality. However, one patient suffered from a transient ischemic attack that resolved within 3 h. Conclusion. We conclude that TRA access for both VA angiographic study and VA stenting is safe and effective, and provides a simple and useful clinical tool for patients unsuited for femoral arterial access

  16. Comparison of closed-cell and hybrid-cell stent designs in carotid artery stenting: clinical and procedural outcomes

    Directory of Open Access Journals (Sweden)

    Ersan TatlI

    2017-05-01

    Full Text Available Introduction: Carotid artery stenting (CAS is a promising alternative to surgery in high-risk patients. However, the impact of stent cell design on outcomes in CAS is a matter of continued debate. Aim : To compare the periprocedural and clinical outcomes of different stent designs for CAS with distal protection devices. Material and methods : All CAS procedures with both closed- and hybrid-cell stents performed at our institution between February 2010 and December 2015 were analyzed retrospectively. Adverse events were defined as death, major stroke, minor stroke, transient ischemic attack and myocardial infarction. Periprocedural and 30-day adverse events and internal carotid artery (ICA vasospasm rates were compared between the closed-cell and hybrid-cell stent groups. Results : The study included 234 patients comprising 146 patients with a closed-cell stent (Xact stent, Abbott Vascular (mean age: 68.5 ±8.6; 67.1% male and 88 patients with a hybrid-cell stent (Cristallo Ideale, Medtronic (mean age: 67.2 ±12.8; 68.2% male. There was no significant difference between the groups with respect to periprocedural or 30-day adverse event rates. While there was no difference in terms of tortuosity index between the groups, there was a higher procedural ICA vasospasm rate in the closed-cell stent group (35 patients, 23% compared with the hybrid-cell stent group (10 patients, 11% (p = 0.017. Conclusions : The results of this study showed no significant difference in the clinical adverse event rates after CAS between the closed-cell stent group and the hybrid-cell stent group. However, procedural ICA vasospasm was more common in the closed-cell stent group.

  17. Luminal flow amplifies stent-based drug deposition in arterial bifurcations.

    Directory of Open Access Journals (Sweden)

    Vijaya B Kolachalama

    2009-12-01

    Full Text Available Treatment of arterial bifurcation lesions using drug-eluting stents (DES is now common clinical practice and yet the mechanisms governing drug distribution in these complex morphologies are incompletely understood. It is still not evident how to efficiently determine the efficacy of local drug delivery and quantify zones of excessive drug that are harbingers of vascular toxicity and thrombosis, and areas of depletion that are associated with tissue overgrowth and luminal re-narrowing.We constructed two-phase computational models of stent-deployed arterial bifurcations simulating blood flow and drug transport to investigate the factors modulating drug distribution when the main-branch (MB was treated using a DES. Simulations predicted extensive flow-mediated drug delivery in bifurcated vascular beds where the drug distribution patterns are heterogeneous and sensitive to relative stent position and luminal flow. A single DES in the MB coupled with large retrograde luminal flow on the lateral wall of the side-branch (SB can provide drug deposition on the SB lumen-wall interface, except when the MB stent is downstream of the SB flow divider. In an even more dramatic fashion, the presence of the SB affects drug distribution in the stented MB. Here fluid mechanic effects play an even greater role than in the SB especially when the DES is across and downstream to the flow divider and in a manner dependent upon the Reynolds number.The flow effects on drug deposition and subsequent uptake from endovascular DES are amplified in bifurcation lesions. When only one branch is stented, a complex interplay occurs - drug deposition in the stented MB is altered by the flow divider imposed by the SB and in the SB by the presence of a DES in the MB. The use of DES in arterial bifurcations requires a complex calculus that balances vascular and stent geometry as well as luminal flow.

  18. Iliac Artery Stent Placement Relieves Claudication in Patients with Iliac and Superficial Femoral Artery Lesions

    International Nuclear Information System (INIS)

    Ichihashi, Shigeo; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko

    2013-01-01

    Purpose. To evaluate the efficacy of iliac artery stent placement for relief of claudication in patients with both iliac and superficial femoral artery (SFA) lesions. Methods. Stent placement for only iliac artery occlusive disease was performed in 94 limbs (74 patients) with both iliac and SFA occlusive disease on the same limb. All procedures were performed because intermittent claudication did not improve after continuation of antiplatelet medication therapy and home-based exercise for 3 months. Rutherford classification was 2 in 20 limbs and 3 in 74 limbs. Patients with critical limb ischemia were excluded. Median duration of follow-up was 40 months. Primary patency rates of the iliac stent, clinical improvement rates, and risk factors for requiring additional SFA procedures were evaluated. Results. Primary patency rates of the iliac stent at 1, 3, 5, and 7 years were 97, 93, 79, and 79 %, respectively. The initial clinical improvement rate was 87 %. Continued clinical improvement rates at 1, 3, 5, and 7 years were 87, 81, 69, and 66 %, respectively. SFA Trans-Atlantic Inter-Society Consensus (TASC) II C/D lesion was a significant risk factor for requiring additional SFA procedures. Conclusion. Intermittent claudication was relieved by iliac stent placement in most patients with both iliac and SFA lesions. Thus, the indications for treatment of the SFA intended for claudicants should be evaluated after treatment of the iliac lesion.

  19. Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment

    International Nuclear Information System (INIS)

    Higashiura, Wataru; Sakaguchi, Shoji; Morimoto, Kengo; Kichikawa, Kimihiko

    2008-01-01

    We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.

  20. Bioabsorbable coronary stents--are these the next big thing in coronary angioplasty?

    Science.gov (United States)

    Balla, Sudarshan; Aggarwal, Kul; Nistala, Ravi

    2010-06-01

    The role of percutaneous coronary intervention (PCI) in the treatment of coronary artery disease has grown at an astronomical pace. Drug eluting stents (DES) offer advantages over bare metal stents (BMS) such as reduction in early in-stent restenosis rates. However, they have disadvantages like from increased late stent thrombosis when compared with BMS. Furthermore, recent data suggest endothelial dysfunction in the DES stented segments of the arteries. Currently, bioabsorbable stents are under development to avert the complications of DES such as stent thrombosis via degradation of the stent over time. The hypothetical advantage of leaving behind a natural vessel and restoring vasoreactivity may be the almost normal physiology which can be achieved after an intervention with a stent. The ABSORB and the PROGRESS AMS are two of the recent clinical trials that have looked at the outcomes of using bioabsorbable stents. So far, data from these and other studies has yielded mixed results in terms of angiographic and clinical outcomes. Newer stents such as REVA and WHISPER are presently being tested in preclinical and clinical trials. The landscape for bioabsorbable stents is constantly evolving through continued improvisation on existing technology and emergence of new technology. Large scale randomized trials are still needed with adequate long term follow-up for safety and benefits to have mainstream application in coronary artery disease, bioabsorbable stents are a promising innovation in the field of PCI. We review some of the patents and the data that is emerging on bioabsorbable stents in addition to currently ongoing clinical trials.

  1. Drug diffusion and biological responses of arteries using a drug-eluting stent with nonuniform coating

    Directory of Open Access Journals (Sweden)

    Saito N

    2016-03-01

    Full Text Available Noboru Saito, Yuhei Mori, Sayaka Uchiyama Terumo Corporation R&D Center, Inokuchi, Nakai-machi, Ashigarakami-gun, Kanagawa, Japan Abstract: The purpose of this study was to determine the effect of a nonuniform coating, abluminal-gradient coating (AGC, which leaves the abluminal surface of the curves and links parts of the stent free from the drug coating, on the diffusion direction of the drug and the biological responses of the artery to drug-eluting stent (DES by comparing the AGC-sirolimus stent and the conventional full-surface coating (CFC sirolimus stent. The study aimed to verify whether the AGC approach was appropriate for the development of a safer DES, minimizing the risks of stent thrombosis due to delayed endothelialization by the drug and distal embolization due to cracking of the coating layer on the hinge parts of the DES on stent expansion. In the in vitro local drug diffusion study, we used rhodamine B as a model drug, and rhodamine B released from the AGC stent diffused predominantly into the abluminal side of the alginate artery model. Conversely, rhodamine B released from the CFC stent quickly spread to the luminal side of the artery model, where endothelial cell regeneration is required. In the biological responses study, the luminal surface of the iliac artery implanted with the AGC-sirolimus stent in a rabbit iliac artery for 2 weeks was completely covered with endothelial-like cells. On the other hand, the luminal surface of the iliac artery implanted with the CFC-sirolimus stent for 2 weeks only showed partial coverage with endothelial-like cells. While thrombosis was observed in two of the three CFC-sirolimus stents, it was observed in only one of the three AGC-sirolimus stents. Taken together, these findings indicate that the designed nonuniform coating (AGC is an appropriate approach to ensure a safer DES. However, the number of studies is limited and a larger study should be conducted to reach a statistically

  2. Iliac artery stenting in patients with poor distal runoff: Influence of concomitant infrainguinal arterial reconstruction.

    Science.gov (United States)

    Timaran, Carlos H; Ohki, Takao; Gargiulo, Nicholas J; Veith, Frank J; Stevens, Scott L; Freeman, Michael B; Goldman, Mitchell H

    2003-09-01

    Inadequate infrainguinal runoff is considered an important risk factor for iliac stent failure. However, the influence of concomitant infrainguinal arterial reconstruction (CIAR) on iliac stent patency is unknown. This study evaluated the influence of CIAR on outcome of iliac angioplasty and stenting (IAS) in patients with poor distal runoff. Over 5 years (1996 to 2001), 68 IAS procedures (78 stents) were performed in 62 patients with poor distal runoff (angiographic runoff score >or=5). The SVS/AAVS reporting standards were followed to define outcome variables and risk factors. Data were analyzed with both univariate analysis (Kaplan-Meier method [K-M]) and regression analysis (Cox proportional hazards model). Indications for iliac artery stenting were disabling claudication (59%) and limb salvage (41%). Of the 68 procedures, IAS with CIAR was performed in 31 patients (46%), and IAS alone was performed in 37 patients (54%). Patients undergoing IAS with CIAR were older (P =.03) and had more extensive and multifocal iliac artery occlusive disease, with more TASC (TransAtlantic Inter-Society Consensus) type C lesions (P =.03), compared with patients undergoing IAS alone. No other significant differences in risk factors were noted. Runoff scores between patients undergoing IAS with CIAR and those undergoing IAS alone were not significantly different (median runoff scores, 6 [range, 5-8] and 7 [range, 5-9], respectively; P =.77). Primary stent patency rate at 1, 3, and 5 years was 87%, 54%, and 42%, respectively, for patients undergoing IAS with CIAR, and was 76%, 66%, and 55%, respectively, for patients undergoing IAS. Univariate analysis revealed that primary stent patency rate was not significantly different between the 2 groups (K-M, log-rank test, P =.81). Primary graft patency rate for CIAR was 81%, 52%, and 46% at 1, 3, and 5 years, respectively. Performing CIAR did not affect primary iliac stent patency (relative risk, 1.1; 95% confidence interval, 0.49-2.47; P

  3. ILIAC-ARTERY URETERAL-FISTULA ASSOCIATED WITH AN INDWELLING URETERAL STENT

    NARCIS (Netherlands)

    ZWEERS, HMM; VANDRIEL, MF; MENSINK, HJA

    1991-01-01

    We report on a patient with an ureteroiliac artery fistula, which developed after double J stenting. The stent was introduced because of unilateral hydronephrosis 2 months after a Wertheim-Meigs operation preceded by cesium application. The presenting symptom of gross hematuria was initially

  4. Preliminary application of 320-detector spiral CT with ECG editing for assessing coronary artery in-stent restenosis

    International Nuclear Information System (INIS)

    Li Zhiming; Tan Lilian; Li Shuxin; Fu Xi; He Weihong; Liu Ke; Huang Yong; Yu Lin

    2011-01-01

    Objective: To determine the value of 320-detector spiral CT with retrospective ECG gating and editing software for detecting coronary artery in-stent restenosis. Methods: CT scans of 14 patients with coronary artery stnets were retrospectively analyzed. The examinations were performed using a 320-detector spiral CT scanner and retrospective ECG gating combined with ECG editing software. The image quality of reconstructed coronary artery in-stents was compared before and after the editing of synchronously recorded ECG. The paired-sample t test was used for statistical analysis. Results: Before ECG editing, arrhythmia and in-stent artifact resulted in image blurring, missing arterial segments, significant stepladder artifacts or non-visualization of the interior of stents. Of 14 cases before ECG editing, in-stent restenosis was detected in 10 and patency in 3. The coronary artery stent and distal bifurcation were delineated in one patient. After ECG editing, the image quality of coronary artery stents was improved with detection of in-stent restenosis (4 cases) including the one case that not evaluable before ECG editing. The average image quality score before ECG editing (2.14±0.86) was significantly (P<0.001) lower than that after ECG editing (3.07±0.73). Conclusion: Retrospective ECG gating combined with ECG editing of 320-detector spiral CT can reduce the artifacts produced by arrhythmia or in-stent swings and improve the imaging quality of coronary artery stents. (authors)

  5. A randomized trial comparing primary angioplasty versus stent placement for symptomatic intracranial stenosis

    Science.gov (United States)

    Qureshi, Adnan I; Chaudhry, Saqib A; Siddiq, Farhan; Majidi, Shahram; Rodriguez, Gustavo J; Suri, M Fareed K

    2013-01-01

    Background: Both primary angioplasty alone and angioplasty with a self-expanding stent have been compared in non-randomized concurrent clinical studies that suggest equivalent results. However, there is no randomized trial that has compared the two procedures in patients with symptomatic high grade intracranial stenosis. Objective: The primary aim of the randomized trial was to compare the clinical and angiographic efficacy of primary angioplasty and angioplasty followed by stent placement in preventing restenosis, stroke, requirement for second treatment, and death in patients with symptomatic intracranial stenosis. Methods: The study prospectively evaluated efficacy and safety of the two existing neurointerventional techniques for treatment of moderate intracranial stenosis (stenosis ≥ 50%) with documented failure of medical treatment or severe stenosis (≥70%) with or without failure of medical treatment. Results: A total of 18 patients were recruited in the study (mean age [±SD] was 64.7 ± 15.1 years); out of these, 12 were men. Of these 18, 10 were treated with primary angioplasty and 8 were treated with angioplasty followed by self-expanding stent. The technical success rates of intracranial angioplasty and stent placements defined as ability to achieve <30% residual stenosis when assessed by immediate post-procedure angiography was 5 of 10 and 5 of 8 patients, respectively. The total fluoroscopic time (mean [±SD]) was lower in patients undergoing primary angioplasty 37 [±11] min versus those undergoing angioplasty followed by self-expanding stent 42 [±15] min, P = 0.4321. The stroke and death rate within 1 month was very low in both patient groups (1 of 10 versus 0 of 8 patients). One patient randomized to stent placement continued to have recurrent ischemic symptoms requiring another angioplasty in the vertebral artery on post-procedure Day 2. Conclusions: The trial suggests that a randomized trial comparing primary angioplasty to angioplasty

  6. Stent-Assisted Coil Embolization of a Mycotic Renal Artery Aneurysm by Use of a Self-Expanding Neurointerventional Stent

    International Nuclear Information System (INIS)

    Rabellino, Martin; García-Nielsen, Luis; Zander, Tobias; Baldi, Sebastián; Llorens, Rafael; Maynar, Manuel

    2011-01-01

    Mycotic aneurysms are uncommon, especially those located in visceral arteries. We present a case of a patient with two visceral mycotic aneurysms due to bacterial endocarditis, one located in right upper pole renal artery and the second in the splenic artery. Both aneurysms were treated as endovascular embolization using microcoils. In the aneurysm located at the renal artery, the technique of stent-assisted coils embolization was preferred to avoid coils migration due to its wide neck. The stent used was the Solitaire AB, which was designed for the treatment of intracranial aneurysms and was used recently in acute stroke as a mechanical thrombectomy device. Complete embolization of the aneurysm was achieved, preserving all the arterial branches without nephrogram defects in the final angiogram.

  7. The Incidence and Risk Factors of In-Stent Restenosis for Vertebrobasilar Artery Stenting.

    Science.gov (United States)

    Zheng, Dai; Mingyue, Zhu; Wei, Shi; Min, Li; Wanhong, Chen; Qiliang, Dai; Yongjun, Jiang; Xinfeng, Liu

    2018-02-01

    In-stent restenosis (ISR) remains a challenge for vertebrobasilar artery stenting (VBAS). We aimed to investigate the incidence and risk factors of ISR. This was a retrospective study. From July 28, 2005, to July 30, 2015, patients who received VBAS with an angiographic follow-up time of 6 to 12 months after surgery were enrolled. The clinical and angiographic issues were recorded and analyzed. In total, 283 patients with 335 stents were incorporated into the study. Vertebral ostial lesions accounted for 73.4% (246/335) of the lesions. During the follow-up period, 58 patients with 60 stents experienced ISR (>50%). Stepwise logistic regression analysis showed that the degree of residual stenosis, stent diameter, and alcohol consumption were independent predictors of ISR. Our study demonstrated the incidence and risk factors of ISR after VBAS. This retrospective study with the largest cohort to date provided insight into the occurrence of ISR after VBAS. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Potential mechanisms of in-stent occlusion in the femoropopliteal artery: an angioscopic assessment.

    Science.gov (United States)

    Ishihara, Takayuki; Iida, Osamu; Okamoto, Shin; Fujita, Masashi; Masuda, Masaharu; Nanto, Kiyonori; Shiraki, Tatsuya; Kanda, Takashi; Tsujimura, Takuya; Okuno, Shota; Yanaka, Koji; Uematsu, Masaaki

    2017-10-01

    Although stent implantation has become widespread for the treatment of patients with peripheral artery disease with femoropopliteal (FP) lesions, in-stent restenosis, especially in-stent occlusion (ISO), remains as a major concern for refractory recurrence. Furthermore, the mechanisms of ISO in FP lesions have not been well elucidated. We performed angioscopy for 6 lesions (bare-metal stent: 3, drug-eluting stent: 3) from 5 patients (mean age 74 ± 10 years, male 40 %) with ISO in the FP artery immediately after wire-passing or thrombus aspiration. The presence of thrombus as well as the presence and location of organic stenosis were evaluated. Median duration from stent implantation to angioscopic evaluation was 1099.5 (514.5-2272.5) days, while the duration from recurrence of symptoms to angioscopic evaluation was 45 (5.75-60) days. Mixed thrombi were observed in all stents. Organic stenosis was detected at the proximal edge of the stents in 5 lesions. Organic stenosis was observed at the overlapping segment of the stent in one lesion. The distal edge of the stents could be evaluated in 3 lesions, and all of them showed organic stenosis at the site. Mixed thrombi and organic stenosis were observed in all stents. Partial development of organic stenosis in a stent followed by thrombus formation may be the potential mechanism of the development of ISO in the FP artery though the sample size of this study was small and it had no serial angioscopic data so that we should consider it as preliminary one at best.

  9. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model

    Science.gov (United States)

    Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R

    2011-01-01

    Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363

  10. Drug-eluting versus bare-metal stents in large coronary arteries

    DEFF Research Database (Denmark)

    Kaiser, Christoph; Galatius, Soeren; Erne, Paul

    2010-01-01

    Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether...

  11. Design of the Revascularization With Open Bypass vs Angioplasty and Stenting of the Lower Extremity Trial (ROBUST): a randomized clinical trial.

    Science.gov (United States)

    Malas, Mahmoud B; Qazi, Umair; Glebova, Natalia; Arhuidese, Isibor; Reifsnyder, Thomas; Black, James; Perler, Bruce A; Freischlag, Julie A

    2014-12-01

    To our knowledge, there is no level 1 evidence comparing open bypass with angioplasty and stenting in TransAtlantic Inter-Society Consensus (TASC II) B and C superficial femoral artery lesions. The Revascularization With Open Bypass vs Angioplasty and Stenting of the Lower Extremity Trial (ROBUST) is the first prospective randomized clinical trial comparing both treatments. To report the design of the ROBUST trial. The primary aim of the trial is to compare (1) the patency rate (primary, primary assisted, and secondary patency at 6 and 12 months), (2) improvement of quality of life, (3) clinical improvement (at least 1 Rutherford category), and (4) wound healing and limb salvage in patients presenting with critical limb ischemia; secondary aims include (1) cost-effectiveness by factoring procedure and hospital admission costs including rehabilitation, readmission, and reintervention costs, (2) amputation-free survival, (3) reintervention rate, and (4) 30-day operative mortality, morbidity, and wound and access complications. ROBUST is a prospective randomized clinical trial with the aim to enroll 320 patients with intermittent claudication that does not respond to medical management and patients with critical limb ischemia. The maximum level of medical therapy will be administered using antiplatelet agents and statins, as well as measures to control hypertension and diabetes mellitus. Patients with TASC II B or C lesions are prospectively randomized to receive either femoropopliteal bypass or percutaneous transluminal angioplasty and stenting; patients with TASC II A and D lesions are not randomized and receive percutaneous transluminal angioplasty and stenting or femoropopliteal bypass, respectively. All patients will be evaluated at 1, 6, and 12 months postoperatively with physical examination, ankle brachial index, duplex, and a quality-of-life questionnaire. The trial is actively enrolling participants. At the time of writing, 29 patients have been enrolled

  12. Dual-therapy stent technology for patients with coronary artery disease : A great catch?

    NARCIS (Netherlands)

    Kalkman, D.N.

    2018-01-01

    This thesis investigates the possible advantages of a new stent technology that aims to improve care for patients with coronary artery disease. The COMBO stent (OrbusNeich Medical BV, The Netherlands) contains a dual-therapy stent technology. The stent combines two techniques: a sirolimus-elution

  13. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona; Cowling, Mark G.; Taube, David; Wright, Andrew R.

    2004-01-01

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, the DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography

  14. Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques.

    Science.gov (United States)

    Fan, Zhenmin; Liu, Xiao; Sun, Anqiang; Zhang, Nan; Fan, Zhanming; Fan, Yubo; Deng, Xiaoyan

    2017-10-01

    Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the possibility, we constructed a patient-specific carotid model with two components of plaques (lipid and calcified plaque) based on MRI images; we numerically compared three different stenting scenarios in terms of von Mises stress (VMS) distribution in the treated arteries, namely, the short stenting (LAM), the medium stenting and the long stenting. The results showed that the short stenting led to more areas with abnormally high VMS along the inner surface of the treated artery with a much higher surface-averaged VMS at the distal end of the stent than both the medium and long stenting. While the VMS distribution in the calcified plaques was similar for the three stenting models, it was quite different in the lipid plaques among the three stenting models. The lipid plaque of the short-stent model showed more volume of the lipid plaque subjected to high VMS than those of the other two models. Based on the obtained results, we may infer that the short stenting (i.e., LAM) may aggravate vascular injury due to high VMS on the artery-stent interaction surface and within the lipid plaque. Therefore, to obtain a better outcome, a longer stent, rather than a short one, might be needed for arterial stenting. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Early experience with the multilayer aneurysm repair stent in the endovascular treatment of trans/infragenicular popliteal artery aneurysms: a mixed bag.

    Science.gov (United States)

    Thakar, Tejal; Chaudhuri, Arindam

    2013-06-01

    To present a preliminary experience using a multilayer flow-modulating stent for trans/infragenicular popliteal endovascular aneurysm repair. Five men (mean age 76 years, range 62-86) with 6 popliteal artery aneurysms (PAAs) measuring 22 to 39 mm in diameter (mean 30) underwent endovascular repair using the Cardiatis Multilayer Aneurysm Repair System (MARS) between June and August 2011. Radiological assessments post procedure using duplex ultrasonography and biplanar knee radiographs (additional contrast studies as necessary) sought evidence of aneurysm exclusion, graft patency, and preservation of branches and runoff vessels. Technical success was achieved in each case. There was one symptomatic stent occlusion requiring thrombectomy at 4 days, with reocclusion, and one leak via the stent struts into the sac with no branch outflow identified. Two further symptomatic stent occlusions were identified within a 6-week follow-up period, totaling 3 occlusions among the 6 devices deployed. No firm conclusion can be reached on the efficacy of the MARS in PAAs due to the inherent limitations of this small series, although a 50% thrombosis rate is a poor outcome. The risk of early thrombosis in flow-modulating stents deployed in the popliteal artery exists, as it does with earlier generation stent-grafts. Larger prospective trials and the influence of more aggressive antithrombotic/anticoagulant therapy should be considered to enable accurate evaluation of this device in popliteal artery aneurysms.

  16. Late effects of low-energy gamma-emitting stents in a rabbit iliac artery model

    International Nuclear Information System (INIS)

    Strauss, Bradley H.; Li, Chris; Whittingham, Heather A.; Tio, Fermin O.; Kutryk, Michael J.B.; Janicki, Christian; Sparkes, John D.; Turnlund, Todd; Sweet, William L.

    2002-01-01

    Purpose: To determine the long-term dose response of novel low-dose γ-emitting stents in a rabbit iliac artery model. Methods and Materials: Control stents (n=24) and 103 Pd stents 1.0 to 4.0 mCi (n=36) were implanted in the iliac arteries of 30 New Zealand rabbits. Stents were evaluated by intravascular ultrasound (immediately post procedure and before killing) and by histomorphometry. Results: At 26 weeks, 28 rabbits were killed, with no evidence of stent thrombosis. In the body of the stent there was a dose-response relationship with 50% inhibition of intimal hyperplasia at the highest activity compared to control stents (p=0.07) and a significant increase in intimal hyperplasia at the lowest activity (p 103 Pd stents is feasible with reduction of in-stent hyperplasia in a dose-related manner. However, significant narrowing at the stent edges, increased in-stent hyperplasia at lower activities, and incomplete vascular healing with persistence of immature neointima at higher activities are significant limitations

  17. An everolimus-eluting stent versus a paclitaxel-eluting stent in small vessel coronary artery disease: a pooled analysis from the SPIRIT II and SPIRIT III trials.

    Science.gov (United States)

    Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W

    2010-07-01

    To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.

  18. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Matthias C. Burg

    2011-01-01

    Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  19. Renal artery stenting in solitary functioning kidneys: Technical and clinical results

    International Nuclear Information System (INIS)

    Sahin, Sinan; Cimsit, Cagatay; Andac, Nurten; Baltacioglu, Feyyaz; Tuglular, Serhan; Akoglu, Emel

    2006-01-01

    Objective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions

  20. Renal artery stenting in solitary functioning kidneys: Technical and clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Sinan [Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Hospital, Department of Radiology, Istanbul (Turkey)]. E-mail: sinan.sahin@e-kolay.net; Cimsit, Cagatay [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Andac, Nurten [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Baltacioglu, Feyyaz [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Tuglular, Serhan [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey); Akoglu, Emel [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey)

    2006-01-15

    Objective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions.

  1. Safety of non-ionic contrast media during renal artery stenting

    International Nuclear Information System (INIS)

    Ni Jun; Shen Weifeng; Zhang Ruiyan; Zhang Qi; Zhang Xian; Zheng Aifang

    2004-01-01

    Objective: To evaluate the safety of non-ionic contras media during interventional treatment of renal artery stenosis (RAS). Methods: Fifty four coronary artery disease patients associated with RAS (luminal narrowing > 50%) underwent renal artery stent implantation and percutaneous coronary intervention, only 10 of them with merely renoarterial stenosis undergone renal artery stent implantation. The successful rates of the procedure and complication together with the volumes of contrast media were recorded respectively. And the serum creatine before and 12 hours after the successful procedure were also measured. Results: Both rates of procedural success and complication were similar among the three groups. The serum creatine levels, 12 hours after the procedure, showed no difference in comparing with the baseline. Conclusion: Non-ionic contrast media (Iopamiro 370) could be safely used in patients with RAS. (authors)

  2. Protein losing enteropathy secondary to a pulmonary artery stent

    Directory of Open Access Journals (Sweden)

    Narayanswami Sreeram

    2012-01-01

    Full Text Available A 2-year-old patient with hypoplastic left heart syndrome presented 6 months following Fontan completion with protein-losing enteropathy (PLE. He had undergone stent implantation in the left pulmonary artery after the Norwood procedure, followed by redilation of the stent prior to Fontan completion. Combined bronchoscopic and catheterization studies during spontaneous breathing confirmed left bronchial stenosis behind the stent, and diastolic systemic ventricular pressure during expiration of 25 mm Hg. We postulate that the stent acts as a valve, against which the patient generates high expiratory pressures, which are reflected in the ventricular diastolic pressure. This may be the cause of PLE.

  3. Pulmonary Arterial Stent Implantation in an Adult with Williams Syndrome

    International Nuclear Information System (INIS)

    Reesink, Herre J.; Henneman, Onno D. F.; Delden, Otto M. van; Biervliet, Jules D.; Kloek, Jaap J.; Reekers, Jim A.; Bresser, Paul

    2007-01-01

    We report a 38-year-old patient who presented with pulmonary hypertension and right ventricular dysfunction due to pulmonary artery stenoses as a manifestation of Williams syndrome, mimicking chronic thromboembolic pulmonary hypertension. The patient was treated with balloon angioplasty and stent implantation. Short-term follow-up showed a good clinical result with excellent patency of the stents but early restenosis of the segments in which only balloon angioplasty was performed. These stenoses were subsequently also treated successfully by stent implantation. Stent patency was observed 3 years after the first procedure

  4. Heparin-bonded covered stents versus bare-metal stents for complex femoropopliteal artery lesions: the randomized VIASTAR trial (Viabahn endoprosthesis with PROPATEN bioactive surface [VIA] versus bare nitinol stent in the treatment of long lesions in superficial femoral artery occlusive disease).

    Science.gov (United States)

    Lammer, Johannes; Zeller, Thomas; Hausegger, Klaus A; Schaefer, Philipp J; Gschwendtner, Manfred; Mueller-Huelsbeck, Stefan; Rand, Thomas; Funovics, Martin; Wolf, Florian; Rastan, Aljoscha; Gschwandtner, Michael; Puchner, Stefan; Ristl, Robin; Schoder, Maria

    2013-10-08

    The hypothesis that endovascular treatment with covered stents has equal risks but higher efficacy than bare-metal stents (BMS) in long femoropopliteal artery disease was tested. Although endovascular treatment of short superficial femoral artery lesions revealed excellent results, efficacy in long lesions remains unsatisfactory. In a prospective, randomized, single-blind, multicenter study, 141 patients with symptomatic peripheral arterial disease were assigned to treatment with heparin-bonded, covered stents (Viabahn 72 patients) or BMS (69 patients). Clinical outcomes and patency rates were assessed at 1, 6, and 12 months. Mean ± SD lesion length was 19.0 ± 6.3 cm in the Viabahn group and 17.3 ± 6.6 cm in the BMS group. Major complications within 30 days were observed in 1.4%. The 12-month primary patency rates in the Viabahn and BMS groups were: intention-to-treat (ITT) 70.9% (95% confidence interval [CI]: 0.58 to 0.80) and 55.1% (95% CI: 0.41 to 0.67) (log-rank test p = 0.11); treatment per-protocol (TPP) 78.1% (95% CI: 0.65 to 0.86) and 53.5% (95% CI: 0.39 to 0.65) (hazard ratio: 2.23 [95% CI: 1.14 to 4.34) (log-rank test p = 0.009). In lesions ≥20 cm, (TransAtlantic Inter-Society Consensus class D), the 12-month patency rate was significantly longer in VIA patients in the ITT analysis (VIA 71.3% vs. BMS 36.8%; p = 0.01) and the TPP analysis (VIA 73.3% vs. BMS 33.3%; p = 0.004). Freedom from target lesion revascularization was 84.6% for Viabahn (95% CI: 0.72 to 0.91) versus 77.0% for BMS (95% CI: 0.63 to 0.85; p = 0.37). The ankle-brachial index in the Viabahn group significantly increased to 0.94 ± 0.23 compared with the BMS group (0.85 ± 0.23; p stents compared with BMS in lesions ≥20 cm and for all lesions in the TPP analysis. In the ITT analysis for all lesions, which was flawed by major protocol deviations in 8.5% of the patients, the difference was not significant. (GORE VIABAHN® endoprosthesis with bioactive propaten surface versus bare

  5. Restenosis after stenting in symptomatic vertebral arterial orifice disease and considerations for better outcome

    Science.gov (United States)

    Chang, Jun Young; Park, Hyun; Kwon, Oki

    2017-01-01

    We have performed stenting in 11 patients with symptomatic vertebral arterial orifice stenosis refractory to medical treatment or impairment in anterior circulation. Three of the 11 patients experienced asymptomatic severe in-stent restenosis or occlusion. Bare metal stents were used in those three patients, two of whom received revascularization therapy. Development of sufficient cervical collateral channels reconstituting the distal vertebral artery was the common feature in patients with asymptomatic in-stent restenosis. In selecting appropriate stents, consideration of mechanical strength and drug-eluting properties of a stent according to characteristics of the target vessel is important to reduce the risk of in-stent restenosis. Any decision to perform revascularization should be based on the presence of abundant cervical collaterals as well as clinical symptoms of vertebrobasilar ischemia. PMID:28304206

  6. Primary Stenting of Subclavian and Innominate Artery Occlusive Disease: A Single Center's Experience

    International Nuclear Information System (INIS)

    Brountzos, E. N.; Petersen, B.; Binkert, C.; Panagiotou, I.; Kaufman, J. A.

    2004-01-01

    Purpose: To review immediate and midterm results of primary stenting for innominate and subclavian artery occlusive lesions. Methods: Retrospective data were collected from 48 consecutive symptomatic patients (27 men and 21 women, median age 64 years) having 49 subclavian and innominate artery lesions treated with stenting. Of the patients 52% had concomitant ischemic heart disease, and 30% had carotid and/or vertebral artery disease. Indication for treatment was vertebrobasilar insufficiency (VBI) in 16.6% of the patients; upper limb ischemia (ULI) in 31.3%; VBI and ULI in 12.5%; transient ischemic attack in 16.7%; angina in 12.5% before or after left internal mammary artery-to-coronary artery bypass grafting; and leg claudication in 10.4% before or after axillofemoral bypass grafting. Balloon-expandable stents were used in 44 lesions and self-expandable stents in 5 lesions. In total, 53 stents were placed in 48 patients. Results: Technical success was 96%, and clinical success 94%. We encountered four complications (two puncture site hematomas, one distal hand embolization and one transient cerebral ischemia). Two patients died within 30 days from other causes, and seven patients were lost to follow-up. Mean follow-up time was 16.7 months (range 0.3 to 68.2). Five patients had recurrent lesions treated by surgical (n = 2) or endovascular (n = 3) means. Cumulative primary patency rate was 91.7% and 77% at 12 and 24 months, respectively. Cumulative secondary patency rate was 96.5% and 91.7% at 12 and 24 months, respectively. Conclusion: Stenting of subclavian and innominate artery lesions resulted in immediate resolution of patients' symptoms with durable midterm effect and few complications in a larger patient group with serious comorbid conditions

  7. Percutaneous Coronary Intervention of Left Main Disease: Pre- and Post-EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) Era.

    Science.gov (United States)

    Park, Duk-Woo; Park, Seung-Jung

    2017-06-01

    For nearly half a century, coronary artery bypass grafting has been the standard treatment for patients with obstructive left main coronary artery (LMCA) disease. However, there has been considerable evolution in the field of percutaneous coronary intervention, and especially, percutaneous coronary intervention for LMCA disease has been rapidly expanded with adoption of drug-eluting stents. Some, but not all randomized trials, have shown that percutaneous coronary intervention with drug-eluting stents might be a suitable alternative for selected patients with LMCA disease instead of bypass surgery. However, none of previous trials involving early-generation drug-eluting stents was sufficiently powered and comparative trials using contemporary drug-eluting stents were limited. Recently, primary results of 2 new trials of EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) were reported. However, these trials showed conflicting results, which might pose uncertainty on the optimal revascularization strategy for LMCA disease. In this article, with the incorporation of a key review on evolution of LMCA treatment, we summarize the similarity or disparity of the EXCEL and NOBLE trials, focus on how they relate to previous trials in the field, and finally speculate on how the treatment strategy may be changed or recommended for LMCA treatment. © 2017 American Heart Association, Inc.

  8. Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

    International Nuclear Information System (INIS)

    Huet, Nicolas; Rodiere, Mathieu; Badet, Michel; Michoud, Marie; Brichon, Pierre-Yves; Ferretti, Gilbert; Thony, Frédéric

    2016-01-01

    We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

  9. Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

    Energy Technology Data Exchange (ETDEWEB)

    Huet, Nicolas, E-mail: nhuet@chu-grenoble.fr; Rodiere, Mathieu, E-mail: mrodiere@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France); Badet, Michel, E-mail: michel.badet@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, site de Chambéry, Intensive Care Unit (France); Michoud, Marie, E-mail: marie.michoud@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, Site de Chambéry, Department of Radiology (France); Brichon, Pierre-Yves, E-mail: pybrichon@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Thoracic and Vascular Surgery (France); Ferretti, Gilbert, E-mail: gferretti@chu-grenoble.fr; Thony, Frédéric, E-mail: fthony@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France)

    2016-05-15

    We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

  10. Angle change of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms

    International Nuclear Information System (INIS)

    Cho, W.-S.; Kang, H.-S.; Kim, J.E.; Kwon, O.-K.; Oh, C.W.; Cho, Y.D.; Han, M.H.

    2014-01-01

    Aim: To investigate the angle changes of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms. Materials and methods: The adjacent parent arterial angles before and after stent-assisted coil embolization were measured in 38 patients with aneurysms of the anterior communicating artery (ACoAA) and 41 patients with bifurcation aneurysms of the middle cerebral artery (MCABA). Variables were analysed in relation to the angle changes. Results: Vascular angles of the parent arteries significantly increased by 27.8° (±18.5°) immediately after stent-assisted coil embolization in 79 cases (p < 0.001), with 25.7° (±14.8°) in ACoAA and 29.7° (±21.4°) in MCABA, respectively. In 51 (64.6%) cases with follow-up angiography (mean interval 13.5 ± 4.1 months), vascular angles increased by 27.2° (±17.1°) immediately after treatment and further increased by 20.7° (±14.3°) at the last follow-up (all p < 0.001). More acute pre-stent angles of the parent arteries correlated with greater post-stent angle changes (p = 0.006). Younger age tended to be inversely related to post-stent angle changes (p = 0.091). Conclusion: Stent placement during coil embolization induced significant changes in the aneurysm–parent artery relationship. Further study is needed to elicit the association between angle change of the parent arteries and aneurysmal stability after coil embolization

  11. Placement of hemoparin-coated stents in the iliac arteries: Early experience and midterm results in 28 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kalmar, Peter I., E-mail: peter.kalmar@medunigraz.at; Portugaller, Rupert H., E-mail: rupert.portugaller@medunigraz.at; Schedlbauer, Peter, E-mail: peter.schedlbauer@klinikum-graz.at; Bohlsen, Dennis, E-mail: dennis.bohlsen@medunigraz.at; Deutschmann, Hannes A., E-mail: hannes.deutschmann@medunigraz.at

    2014-07-15

    Purpose: Aim was to determine immediate results and mid-term outcome of the hemoparin-coated (HC) stainless-steel stent (camouflage coating) in the treatment of occlusive lesions of the iliac arteries. Materials and methods: Twenty-eight patients were prospectively treated with the use of a HC stent between January 2007 and March 2010. Clinical examination and color-doppler ultrasound were performed at 1, 3, 6 and 12 months, CT angiography (CTA) or MR angiography (MRA) at 12 months. Indication for treatment was a high-grade stenosis of the common iliac and/or external iliac artery. Results: Successful placement was achieved in all patients. Significant decrease in translesional pressure gradient (>10 mmHg) was measured in 27 patients (96%). In one patient, proximal dissection occurred without flow limitation. A minor complication (small access site hematoma) occurred in one patient (4%). Two patients (7%) were lost to follow-up. After 12 months, stent patency in CTA, MRA and ultrasound was 100%. 20 patients (77%) experienced an initial improvement of at least one clinical stage. In one patient (4%), mild intimal hyperplasia without significant stenosis was observed. In three patients (12%), proximal or distal stenosis occurred. A non-significant increase of mean ankle-brachial index (ABI) after treatment was measured (0.85 ± 0.27 vs. 0.75 ± 0.22, respectively; p = 0.328). Conclusions: The use of HC stents in patients with iliac artery occlusive disease may lead to a lower rate of intimal hyperplasia and thus to increased patency rates even in heavily calcified vessels. However, large-scale prospective trials have to be performed to evaluate the long-term patency rates of the HC coated stents.

  12. Placement of hemoparin-coated stents in the iliac arteries: Early experience and midterm results in 28 patients

    International Nuclear Information System (INIS)

    Kalmar, Peter I.; Portugaller, Rupert H.; Schedlbauer, Peter; Bohlsen, Dennis; Deutschmann, Hannes A.

    2014-01-01

    Purpose: Aim was to determine immediate results and mid-term outcome of the hemoparin-coated (HC) stainless-steel stent (camouflage coating) in the treatment of occlusive lesions of the iliac arteries. Materials and methods: Twenty-eight patients were prospectively treated with the use of a HC stent between January 2007 and March 2010. Clinical examination and color-doppler ultrasound were performed at 1, 3, 6 and 12 months, CT angiography (CTA) or MR angiography (MRA) at 12 months. Indication for treatment was a high-grade stenosis of the common iliac and/or external iliac artery. Results: Successful placement was achieved in all patients. Significant decrease in translesional pressure gradient (>10 mmHg) was measured in 27 patients (96%). In one patient, proximal dissection occurred without flow limitation. A minor complication (small access site hematoma) occurred in one patient (4%). Two patients (7%) were lost to follow-up. After 12 months, stent patency in CTA, MRA and ultrasound was 100%. 20 patients (77%) experienced an initial improvement of at least one clinical stage. In one patient (4%), mild intimal hyperplasia without significant stenosis was observed. In three patients (12%), proximal or distal stenosis occurred. A non-significant increase of mean ankle-brachial index (ABI) after treatment was measured (0.85 ± 0.27 vs. 0.75 ± 0.22, respectively; p = 0.328). Conclusions: The use of HC stents in patients with iliac artery occlusive disease may lead to a lower rate of intimal hyperplasia and thus to increased patency rates even in heavily calcified vessels. However, large-scale prospective trials have to be performed to evaluate the long-term patency rates of the HC coated stents

  13. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial.

    Science.gov (United States)

    Serruys, Patrick W; Farooq, Vasim; Kalesan, Bindu; de Vries, Ton; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Eberli, Franz; Wijns, William; Morice, Marie Claude; Di Mario, Carlo; Corti, Roberto; Antoni, Diethmar; Sohn, Hae Y; Eerdmans, Pedro; Rademaker-Havinga, Tessa; van Es, Gerrit-Anne; Meier, Bernhard; Jüni, Peter; Windecker, Stephan

    2013-08-01

    This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority 1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Mayer, T.E. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Henkes, H. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Kis, B. [Department of Neurology, Alfried Krupp Hospital, Essen (Germany) and Department of Psychiatry and Psychotherapy, University of Duisburg-Essen, Virchow Street 174, D-45147 Essen (Germany)]. E-mail: bernhard.kis@uni-duisburg-essen.de; Hamann, G.F. [Department of Neurology, Klinikum Grosshadern, University of Munich (Germany); Holtmannspoetter, M. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Brueckmann, H. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Kuehne, D. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany)

    2005-11-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found.

  15. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    International Nuclear Information System (INIS)

    Weber, W.; Mayer, T.E.; Henkes, H.; Kis, B.; Hamann, G.F.; Holtmannspoetter, M.; Brueckmann, H.; Kuehne, D.

    2005-01-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found

  16. Investigation of adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents in the iliac vein: insights into developing a better iliac vein stent.

    Science.gov (United States)

    Shida, Takuya; Umezu, Mitsuo; Iwasaki, Kiyotaka

    2018-06-01

    We analyzed the adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents for the treatment of iliac venous thromboembolism and investigated their relationships with the anatomical features of the iliac vein, to gain insights into the development of a better iliac vein stent. Reports of adverse events following the use of stents in the iliac vein were retrieved from the Manufacturer and User Facility Device Experience (MAUDE) database that contain suspected device-associated complications reported to the Food and Drug Administration. Data from 2006 to 2016 were investigated. The literature analysis was also conducted using PubMed, Cochrane Library, EMBASE, and Web of Science focusing on English articles published up to 4 October 2016. The analysis of 88 adverse events from the MAUDE database and 182 articles from the literature revealed that a higher number of adverse events had been reported following the use of arterial stents in the iliac vein compared to CE-marked iliac vein stents. While stent migration and shortening were reported only for the arterial stents, stent fracture and compression occurred regardless of the stent type, even though a vein does not pulsate. A study of the anatomical features of the iliac vein implies that bending, compression, and kink loads are applied to the iliac vein stents in vivo. For designing, developing, and pre-clinical testing of stents intended for use in the iliac vein, the above mechanical load environments induced by the anatomical features should be considered.

  17. Pancreatitis-Associated Splenic Artery Pseudoaneurysm: Endovascular Treatment with Self-Expandable Stent-Grafts

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vagenas, Kostantinos; Apostolopoulou, Sotiria C.; Panagiotou, Irene; Lymberopoulou, Dimitra; Kelekis, Dimitrios A.

    2003-01-01

    We present a patient with a splenic arterypseudoaneurysm (SAPA) treated with placement of self-expandable stent-grafts. The procedure was complicated by stent-graft migration,but successful management resulted in lasting exclusion of the SAPA,while the patency of the splenic artery was preserved. This is the first report of self-expandable stent-graft treatment of SAPA

  18. Conformally integrated stent cell resonators for wireless monitoring of peripheral artery disease

    KAUST Repository

    Viswanath, Anupam; Green, Scott Ryan; Kosel, Jü rgen; Gianchandani, Yogesh B.

    2013-01-01

    This paper presents the design and in vitro evaluation of magnetoelastic sensors intended for wireless monitoring of tissue accumulation in peripheral artery stents. The sensors, shaped like stent cells, are fabricated from 28-μm thick foils

  19. Percutaneous stenting of the superior mesenteric artery for the treatment of chronic mesenteric ischemia

    International Nuclear Information System (INIS)

    Gweon, Hye Mi; Suh, Sang Hyun; Won, Jong Yun; Lee, Do Yun; Kim, Sam Soo

    2008-01-01

    We wanted to evaluate the effectiveness of stent placement on the superior mesenteric artery as a treatment for chronic mesenteric ischemia. Seven patients (mean age: 55 years, age range: 43-66 years) with chronic mesenteric ischemia were enrolled between March 2000 and September 2003. All the patients underwent pre-procedure contrast enhanced computerized tomography to evaluate for occlusion or stenosis of the mesenteric arteries and they then underwent an angiographic procedure. A balloon-expandable metal stent was placed in the superior mesenteric artery, and this was combined with balloon angioplasty and thrombolysis. We evaluated the angiographic and procedural success after the procedures. Angiographic and procedural success was obtained in 100% of the patients and the clinical symptoms improved in 100% of the patients. The patency at 6-months and 1-year was 85% and 71%, respectively. The mean follow-up period was 12 months (range: 1-25 months). During the follow-up period, ischemic symptoms recurred in 2 patients, and restenosis in a stent was confirmed with angiography; one patient was successfully treated by stent placement in the celiac artery and the other patient died due to extensive mesenteric thrombosis. For the treatment of chronic mesenteric ischemia, percutaneous stent placement on the superior mesenteric artery showed a favorable result and it was an effective alternative to surgery for the high-risk patients

  20. Safety and effectiveness of the INVATEC MO.MA proximal cerebral protection device during carotid artery stenting: results from the ARMOUR pivotal trial.

    Science.gov (United States)

    Ansel, Gary M; Hopkins, L Nelson; Jaff, Michael R; Rubino, Paolo; Bacharach, J Michael; Scheinert, Dierk; Myla, Subbarao; Das, Tony; Cremonesi, Alberto

    2010-07-01

    The multicenter ARMOUR (ProximAl PRotection with the MO.MA Device DUring CaRotid Stenting) trial evaluated the 30-day safety and effectiveness of the MO.MA Proximal Cerebral Protection Device (Invatec, Roncadelle, Italy) utilized to treat high surgical risk patients undergoing carotid artery stenting (CAS). Distal embolic protection devices (EPD) have been traditionally utilized during CAS. The MO.MA device acts as a balloon occlusion "endovascular clamping" system to achieve cerebral protection prior to crossing the carotid stenosis. This prospective registry enrolled 262 subjects, 37 roll-in and 225 pivotal subjects evaluated with intention to treat (ITT) from September 2007 to February 2009. Subjects underwent CAS using the MO.MA device. The primary endpoint, myocardial infarction, stroke, or death through 30 days (30-day major adverse cardiac and cerebrovascular events [MACCE]) was compared to a performance goal of 13% derived from trials utilizing distal EPD. For the ITT population, the mean age was 74.7 years with 66.7% of the cohort being male. Symptomatic patients comprised 15.1% and 28.9% were octogenarians. Device success was 98.2% and procedural success was 93.2%. The 30-day MACCE rate was 2.7% [95% CI (1.0-5.8%)] with a 30-day major stroke rate of 0.9%. No symptomatic patient suffered a stroke during this trial. The ARMOUR trial demonstrated that the MO.MA(R) Proximal Cerebral Protection Device is safe and effective for high surgical risk patients undergoing CAS. The absence of stroke in symptomatic patients is the lowest rate reported in any independently adjudicated prospective multicenter registry trial to date. (c) 2010 Wiley-Liss, Inc.

  1. 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial: A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; Cuesta, Javier; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José Ramón; Masotti, Mónica; Zueco, Javier; Cequier, Angel; Velázquez, Maite; Moreno, Raúl; Mainar, Vicente; Domínguez, Antonio; Moris, Cesar; Molina, Eduardo; Rivero, Fernando; Jiménez-Quevedo, Pilar; Gonzalo, Nieves; Fernández-Pérez, Cristina

    2018-05-28

    This study sought to compare the long-term safety and efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients with in-stent restenosis (ISR) of drug-eluting stents (DES). Treatment of patients with DES-ISR remains a challenge. The RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents) trial is a prospective multicenter randomized clinical trial comparing DEB and EES in patients with DES-ISR. The pre-specified comparison of the 3-year clinical outcomes obtained with these interventions is the main objective of the present study. A total of 309 patients with DES-ISR were randomized to DEB (n = 154) or EES (n = 155). At angiographic follow-up, the in-segment minimal lumen diameter was larger in the EES arm (2.03 ± 0.7 mm vs. 1.80 ± 0.6 mm; p 1 year) target lesion revascularization (2.6% vs. 4%) and target vessel revascularization (4% vs. 6.6%) was similar in the 2 arms. Rates of cardiac death (3.9% vs. 3.2%), myocardial infarction (2.6% vs. 4.5%), and stent thrombosis (1.3% vs. 2.6%) at 3 years were also similar in both arms. The 3-year clinical follow-up of this randomized clinical trial demonstrates that in patients with DES-ISR, EES reduce the need for repeat interventions compared with DEB. (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents [RIBS IV]; NCT01239940). Published by Elsevier Inc.

  2. Clinical experience of cerebral protection with balloon occlusion during carotid artery stenting

    International Nuclear Information System (INIS)

    Jaeger, H.J.; Mathias, K.D.; Drescher, R.; Bockisch, G.; Hauth, E.; Demirel, E.; Gissler, H.M.; Witten/Herdecke Univ.

    2001-01-01

    Purpose: To asses the technical feasibility and the results of cerebral protection with the GuardWire Plus Temporary Occlusion and Aspiration System during carotid artery stenting for high-grade stenosis. Patients and Methods: In 20 patients 20 carotid artery stenoses were treated with stent placement under cerebral protection. A contralateral carotid occlusion was an exclusion criteria for the use of the protection device. In all cases only aspiration, but no flushing was used before deflation of the occlusion balloon. In 17 of 20 patients diffusion-weighted (DW-)MRT imaging of the brain was performed before and 24 hours after the procedure. Results: The stent implantation was successfully performed in all patients. In 3 patients neurologic symptoms occurred during the occlusion time. In these 3 patients the symptoms immediately disappeared after deflation of the balloon. In one case there was dilatation of the internal carotid artery at the site of the balloon inflation. In 3 of the 17 DW-MR images new ipsilateral cerebral lesions, in one case a new contralateral lesion occurred after the procedure. Conclusions: The cerebral protection procedure is technically feasible. The occlusion of the internal carotid artery was not tolerated by all patients. The DW-MR imaging demonstrated cerebral lesions indicating the occurrence of cerebral microemboli during the procedure. Further investigations are necessary to determine if the use of the cerebral protection device will improve the results of the carotid artery stenting for high-grade stenoses. (orig.) [de

  3. Influence of stent design and use of protection devices on outcome of carotid artery stenting: a pooled analysis of individual patient data.

    Science.gov (United States)

    Wodarg, Fritz; Turner, Elisabeth L; Dobson, Joanna; Ringleb, Peter A; Mali, Willem P; Fraedrich, Gustav; Chatellier, Gilles; Bequemin, Jean-Pierre; Brown, Martin M; Algra, Ale; Mas, Jean-Louis; Jansen, Olav; Bonati, Leo H

    2018-04-19

    Carotid artery stenting is an alternative to endarterectomy for the treatment of symptomatic carotid stenosis but was associated with a higher risk of procedural stroke or death in randomized controlled trials (RCTs). Technical aspects of treatment may partly explain these results. The purpose of this analysis was to investigate the influence of technical aspects such as stent design or the use of protection devices, as well as clinical variables, on procedural risk. We pooled data of 1557 individual patients receiving stent treatment in three large RCTs comparing stenting versus endarterectomy for symptomatic carotid stenosis. The primary outcome event was any procedural stroke or death occurring within 30 days after stenting. Procedural stroke or death occurred significantly more often with the use of open-cell stents (61/595 patients, 10.3%) than with closed-cell stents (58/962 patients, 6.0%; RR 1.76; 95% CI 1.23 to 2.52; P=0.002). Procedural stroke or death occurred in 76/950 patients (8.0%) treated with protection devices (predominantly distal filters) and in 43/607 (7.1%) treated without protection devices (RR 1.10; 95% CI 0.71 to 1.70; P=0.67). Clinical variables predicting the primary outcome event were age, severity of the qualifying event, history of prior stroke, and level of disability at baseline. The effect of stent design remained similar after adjustment for these variables. In symptomatic carotid stenosis, the use of stents with a closed-cell design is independently associated with a lower risk of procedural stroke or death compared with open-cell stents. Filter-type protection devices do not appear to reduce procedural risk. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Effects of 32P radioactive stents on in-stent restenosis in a double stent injury model of the porcine coronary arteries

    International Nuclear Information System (INIS)

    Kim, Han-Soo; Chan, Rosanna C.; Kollum, Marc; Au, Arthur; Tio, Fermin O.; Yazdi, Hamid A.; Ajani, Andrew E.; Waksman, Ron

    2001-01-01

    Background: The major limitation of coronary stenting remains in-stent restenosis, due to the development of neointimal proliferation. Radioactive stents have demonstrated the ability to reduce this proliferation in the healthy nonatherosclerotic porcine animal model. However, inhibition of tissue proliferation in the in-stent restenotic lesion in a porcine model is not well characterized. The objective of this study was to examine the efficacy and safety of the 32 P radioactive stent for the treatment of in-stent restenosis in a double stent injury model of the porcine coronaries. Methods and Materials: Eighteen coronary arteries in 9 pigs underwent nonradioactive stent (8 mm in length) implantation. Thirty days after the initial stent implantation, a 32 P radioactive stent (18 mm in length) with an activity of 0 and 18 μCi was implanted to cover the initial stent. The swine were killed 30 days after the second stent implantation. Histomorphometric analysis was performed for vessel area (VA), stent strut area (SSA), intimal area (IA), and lumen area (LA). Results: Injury scores, VA, SSA, and LA were similar among the control and radiated groups. Neointimal formation was significantly reduced after placement of radioactive stents as compared to control in both the overlapped (0.93±0.12 vs. 1.31±0.51 mm 2 , p 2 , p 32 P radioactive stents may be safe and effective in reducing neointimal formation leading to in-stent restenosis. Longer follow-up will be required to examine whether these positive findings can be maintained

  5. Kissing stenting of aorto-ostial lesions in juxtaposed renal arteries

    OpenAIRE

    Hasija, Pradeep; Chadha, Davinder; Kalra, Ravi

    2014-01-01

    Percutaneous angioplasty with or without stenting has become an established procedure for treatment of renal artery stenosis for control of hypertension or progressive renal dysfunction. Anatomic variation of renal arteries is common with dual blood supply of unilateral kidney noted in almost 25% of the general population. Renal angioplasty of these anatomic variants of renal arteries is challenging. We present an unusual case of juxtaposed renal arteries with aorto-ostial lesion where direct...

  6. Complications in percutaneous transluminal stenting for carotid artery stenosis

    International Nuclear Information System (INIS)

    Li Shenmao; Miao Zhongrong; Zhu Fengshui; Ji Xunming; Jiao Liqun; Qi Jianshu; Ling Feng

    2007-01-01

    Objective: To discuss the complications of endovascular stenting for carotid artery stenosis. Methods: Cerebral vascular angiography and cervical Doppler sonography were performed in 648 patients with carotid artery stenosis. Emboli-protected device was used in 365 patients and none in 283 patients. Results: All 648 patients were technically successful (100%). Symptoms disappeared or improved in 78.7% patients. Slow heart rate during operation existed in 26.4% patients. Embolism caused by dislodgment of emboli occurred in 5 patients, 3 of them recovered after treatment and 2 had unilateral dyskinesias. Intracranial hemorrhage occurred in 3 patients. Stroke or death within 30 days after operation occurred in 6 patients(1.24%). 322 patients (77.8%)were followed up. Restenosis occurred in 17 patients(3.3%). Conclusion: Percutaneous transluminal stenting is a safe option for carotid artery stenosis. Correct evaluation of clinical and angiographic data before operation, together with normative manipulation and nursing during and after operation are the key points to avoid complications. (authors)

  7. Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations--animal and clinical studies in stented and non-stented coronary arteries.

    Science.gov (United States)

    Tardif, J C; Bertrand, O F; Mongrain, R; Lespérance, J; Grégoire, J; Paiement, P; Bonan, R

    2000-10-01

    Both mechanical and multi-element intravascular ultrasound designs have potential advantages and limitations that may impact on their value for clinical and research purposes. Determination of the reproducibility of measurements is critical before a given system can be used in studies such as regression of atherosclerosis trials. We performed serial intravascular ultrasound imaging with catheters using mechanical and phased-array designs in stented and non-stented coronary arteries in dogs and in patients. Both systems correlated well for areas (r > or = 0.90, p or = 0.84. p mechanical designs for measurements of area (mean difference in dogs and in patients: -0.24 and 0.96 mm2, p mechanical system (r > or = 0.96 for all measurements). The differences in absolute and relative variability between the mechanical and phased-array designs, both for reanalysis of same frames and serial pullbacks, were very small. Although multi-element and mechanical intravascular ultrasound designs are not strictly interchangeable, their similar reproducibility and the small differences in measurements demonstrate that both designs are acceptable alternatives for trials of regression of atherosclerosis. Determination of the variability for serial pullbacks of both designs was also important to assess the statistical power of such trials.

  8. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  9. Orbital atherectomy as an adjunct to debulk difficult calcified lesions prior to mesenteric artery stenting.

    Science.gov (United States)

    Manunga, Jesse M; Oderich, Gustavo S

    2012-08-01

    To describe a technique in which percutaneous orbital atherectomy is used to debulk heavily calcified superior mesenteric artery (SMA) occlusions as an adjunct in patients undergoing angioplasty and stenting. The technique is demonstrated in a 62-year-old woman with a replaced right hepatic artery originating from an SMA occluded by densely calcified lesions. Via a left transbrachial approach, a 7-F MPA guide catheter was used to engage the ostium of the SMA, which was crossed using a catheter and guidewire. The calcified lesion was debulked using the 2-mm Diamondback 360° orbital atherectomy system. The wire was exchanged for a 0.014-inch filter wire and 0.018-inch guidewire. Using a 2-guidewire technique, the SMA was stented with a self-expanding stent for the distal lesion that crossed side branches and a balloon-expandable stent at the ostium. A 0.014-inch guidewire was placed into the replaced hepatic artery through a cell of the self-expanding stent, followed by deployment of a small balloon-expandable stent to address the residual lesion. The use of orbital atherectomy to debulk occluded and heavily calcified SMA lesions may optimize the technical results with angioplasty and stenting.

  10. Long term outcomes of new generation drug eluting stents versus coronary artery bypass grafting for multivessel and/or left main coronary artery disease. A Bayesian network meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Mina, George S; Watti, Hussam; Soliman, Demiana; Shewale, Anand; Atkins, Jessica; Reddy, Pratap; Dominic, Paari

    2018-01-05

    Most data guiding revascularization of multivessel disease (MVD) and/or left main disease (LMD) favor coronary artery bypass grafting (CABG) over percutaneous coronary intervention (PCI). However, those data are based on trials comparing CABG to bare metal stents (BMS) or old generation drug eluting stents (OG-DES). Hence, it is essential to outcomes of CABG to those of new generation drug eluting stents (NG-DES). We searched PUBMED and Cochrane database for trials evaluating revascularization of MVD and/or LMD with CABG and/or PCI. A Bayesian network meta-analysis was performed to calculate odds ratios (OR) and 95% credible intervals (CrI). Primary outcome was major adverse cardiovascular events (MACE) at 3-5 years. Secondary outcomes were mortality, cerebrovascular accidents (CVA), myocardial infarction (MI) and repeat revascularization. We included 10 trials with a total of 9287 patients. CABG was associated with lower MACE when compared to BMS or OG-DES. However, MACE was not significantly different between CABG and NG-DES (OR 0.79, CrI 0.45-1.40). Moreover, there were no significant differences between CABG and NG-DES in mortality (OR 0.78, CrI 0.45-1.37), CVA (OR 0.93 CrI 0.35-2.2) or MI (OR 0.6, CrI 0.17-2.0). On the other hand, CABG was associated with lower repeat revascularization (OR 0.55, CrI 0.36-0.84). Our study suggests that NG-DES is an acceptable alternative to CABG in patients with MVD and/or LMD. However, repeat revascularization remains to be lower with CABG than with PCI. Copyright © 2018. Published by Elsevier Inc.

  11. Percutaneous transluminal angioplasty and stent placement for iliofemoral arterial atherosclerotic occlusive disease

    International Nuclear Information System (INIS)

    Zheng Yanbo; Jiang Wenjin; Liu Sheng; Song Xuepeng; Sheng Qirui

    2006-01-01

    Objectives: To assess the safety and efficacy of percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of iliofemoral arterial atherosclerotic occlusive diseases. Methods From April 1999 to August 2004, 13 cases of iliofemoral arterial occlusions were recanalized with contact thrombolytic therapy combined with guide wire mechanical recanalization method, followed by angioplasty and stent placement. A total of 25 self-expanding Wallstents were deployed. All patients were followed up by means of duplex ultrasound, angiography, or both. Results: All 13 cases were successfully recanalized, with technical successful rate of 100%. Available follow-up for all patients from 8 months-5 years (mean 26.2 months) included one patient undergoing again with successful contact thrombolysis because of early thrombosis; another patient with recurrent symptoms at 19 month after operation undertaking surgical bypass because of later reocclusion; all of the rest stents showing patency by the end of the study. Conclusions: Contact thrombolysis combined with guide wire mechanical recanalization for iliofemoral arterial occlusion is safe and effective, whereas PTA and stent placement would have the nearly same efficacy for the disease with mild injury and low restenosis. (authors)

  12. High-dose external beam irradiation inhibits neointima formation in stented pig coronary arteries

    International Nuclear Information System (INIS)

    Verheye, Stefan; Coussement, Patrick K.; Salame, Mahomed Y.; Fallahi, Payam; Cui Jianhua; Chronos, Nicolas A.F.; King, Spencer B.; Crocker, Ian R.; Robinson, Keith A.

    2001-01-01

    Purpose: To evaluate high-dose external beam irradiation (EBRT) in a pig coronary stent preparation because low and intermediate-dose EBRT failed to show inhibition of neointima formation in stented animal models. Methods and Materials: Thirty-five stents were implanted in the coronary arteries of 17 pigs. Seven pigs were exposed to a single dose of 21 Gy EBRT immediately after stenting. Ten stented, nonirradiated pigs served as controls. After 4 weeks, the study arteries and myocardium were examined by light and scanning electron microscopy. Results: Compared with controls, 21 Gy EBRT resulted in a larger lumen area (7.57±1.67 mm 2 vs. 4.00±1.63 mm 2 , p 2 vs. 3.36±2.26 mm 2 , p<0.001) and a smaller maximal intimal thickness (0.16±0.09 mm vs. 0.68±0.31 mm, p<0.001). Unresorbed intramural hemorrhages and adherent mural thrombi were present in the irradiated vessels, which also showed incomplete re-endothelialization. The irradiated hearts demonstrated diffuse interstitial and perivascular inflammation and fibrosis. Conclusions: EBRT at 21 Gy to the entire heart significantly inhibited neointima formation in stented pig coronary arteries but also resulted in incomplete re-endothelialization, myocardial inflammation, and fibrosis. Improvements in localization and delivery techniques are required to allow clinical implementation of this technique

  13. Wingspan stent for symptomatic M1 stenosis of middle cerebral artery

    International Nuclear Information System (INIS)

    Guo Xinbin; Ma Nan; Hu Xiaobo; Guan Sheng; Fan Yimu

    2011-01-01

    Objective: Stent placement for intracranial atherosclerotic stenosis has become an alternative treatment technique; however, stent placement for middle cerebral artery (MCA) stenosis remains a technical and clinical challenge. Our purpose was to assess the safety and feasibility of Wingspan stent for patients with symptomatic M1 stenosis, and its initial effect on prevention of ischemic events. Methods: Fifty-three cases with recurrent symptomatic MCA stenosis resistant to medical therapy treated by self-expanding stent were reviewed retrospectively (average 58 ± 18.5 years old, 19 women). All patients underwent angioplasty and stenting with the Gateway balloon–Wingspan stent system, and advised follow-up with DSA or TCD at 6th month. Results: Patients had an average stenosis ratio of 76.5 ± 15.4% prior to the treatment. Of the 53 patients, the technical success rate was 98.1% as a whole (52/53). The mean degree of stenosis reduced from (76.5 ± 15.4)% to (18.2 ± 11.3)%. Complications associated with the procedure include subarachnoid hemorrhage (1.89%) and occlusion (3.78%) occurred. During a follow-up of 6 months, there was no recurrence of transient ischemic attack or stroke in 52 cases with successful stenting. Cerebral hemodynamics of MCA using transcranial Doppler monitoring were at normal level (<120 cm/s) in 41 follow-up patients. The follow up angiography at 6 month post-procedure was conducted in 32 patients and showed good patency in stented vessels. Conclusions: Wingspan stent for symptomatic stenosis of middle cerebral artery is a safe and feasible procedure. It improves clinical outcome in the intermediate follow up, but its long-term effect remains to be further evaluated.

  14. Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Vejlstrup, Niels Grove; Ahtarovski, Kiril Aleksov

    2012-01-01

    Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year. This case...... report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology. While...... the signal loss on MRI associated with implanted metallic devices is known, we report a case where an implanted coronary stent in the left circumflex artery led to an intracardiac signal loss mimicking intracardiac thrombus/tumor....

  15. The risk of endoleak following stent covering of the internal iliac artery during endovascular aneurysm repair

    International Nuclear Information System (INIS)

    Rajesparan, K.; Partridge, W.; Refson, J.; Abidia, A.; Aldin, Z.

    2014-01-01

    Aim: To investigate the risk of endoleak during endovascular aneurysm repair (EVAR) involving the distal common iliac artery (CIA) when the internal iliac artery (IIA) is covered without prior coil embolization. Materials and methods: Retrospective analysis of 145 (125 men, 20 women) consecutive EVAR cases. Clinical notes and radiological images were reviewed, and data collected on patient demographics, aneurysm morphology, covering of the IIA with or without embolization, presence of endoleaks, and patient symptoms relating to IIA ischaemia. Results: A total of 29 IIAs (10%) were covered in a total of 25 patients. Seven IIAs (24%) were embolized before stent covering (Embolization group), and 22 IIAs (76%) were covered only without embolization (Cover group). There was no statistically significant difference in the mean size of the abdominal aortic aneurysm diameter or CIA diameter between each group. No endoleaks from IIA retrograde filling were found in either group. Conclusion: The results of the present study do not support the traditional view that coverage of the IIA without prior embolization carries a high risk of endoleak, with no endoleaks seen in all 22 cases. Large-scale trials are required. However, the advent of branched-stenting techniques and the emergence of their success in long-term follow-up may preclude the former. - Highlights: • No EVAR endoleaks due to retrograde filling of the internal iliac artery (IIA). • No increased risk of endoleak with stent coverage of the IIA without embolisation. • Current evidence does not support traditional views

  16. Intravascular stenting in the superior mesenteric artery for chronic abdominal angina.

    Science.gov (United States)

    Busquet, J

    1997-11-01

    Abdominal angina is an early clinical expression of occlusive mesenteric arterial insufficiency, a condition that requires aggressive treatment to prevent intestinal infarction. We report a case of chronic mesenteric ischemia in a young polyvascular man who had symptoms of abdominal angina. An aortic angiogram revealed a significant ostial stenosis of the superior mesenteric artery (SMA) associated with an occlusion of the inferior mesenteric artery. After predilation of the ostial portion of the SMA, significant residual stenosis remained. A balloon-expandable Palmaz P154 stent was deployed, restoring adequate luminal dimensions and blood flow. The patient was discharged after 2 days and remains asymptomatic at 5 months. Intraluminal stenting for treatment of mesenteric ischemia represents a viable alternative to surgical revascularization in selected cases.

  17. Second generation drug-eluting stents versus bare-metal stents for percutaneous coronary intervention of the proximal left anterior descending artery

    DEFF Research Database (Denmark)

    Mangione, Fernanda Marinho; Biering-Sørensen, Tor; Nochioka, Kotaro

    2017-01-01

    OBJECTIVES: To compare mid-term outcomes between patients undergoing proximal left anterior descending artery (LAD) percutaneous coronary intervention (PCI) with second generation drug-eluting stent (DES) or bare-metal stent (BMS). BACKGROUND: PCI with BMS and first-generation DES have shown to b...

  18. Valve-Like and Protruding Calcified Intimal Flap Complicating Common Iliac Arteries Kissing Stenting

    Directory of Open Access Journals (Sweden)

    George S. Georgiadis

    2015-01-01

    Full Text Available Endovascular therapy for iliac artery chronic total occlusions is nowadays associated with low rates of procedure-related complications and improved clinical outcomes, and it is predominantly used as first-line therapy prior to aortobifemoral bypass grafting. Herein, we describe the case of a patient presenting with an ischemic left foot digit ulcer and suffering complex aortoiliac lesions, who received common iliac arteries kissing stents, illustrating at final antegrade and retrograde angiograms the early recognition of a blood flow obstructing valve-like calcified intimal flap protruding through the stent struts, which was obstructing antegrade but not retrograde unilateral iliac arterial axis blood flow. The problem was resolved by reconstructing the aortic bifurcation at a more proximal level. Completion angiogram verified normal patency of aorta and iliac vessels. Additionally, a severe left femoral bifurcation stenosis was also corrected by endarterectomy-arterioplasty with a bovine patch. Postintervention ankle brachial pressure indices were significantly improved. At the 6-month and 2-year follow-up, normal peripheral pulses were still reported without intermittent claudication suggesting the durability of the procedure. Through stent-protruding calcified intimal flap, is a very rare, but existing source of antegrade blood flow obstruction after common iliac arteries kissing stents.

  19. Drug-eluting stent implantation for the percutaneous treatment of vertebro-basilar arterial stenosis

    International Nuclear Information System (INIS)

    Ma Rujun; Liu Jianmin; Huang Haiqing; Hong Bo; Xu Yi; Zhao Wenyuan; Zhao Rui; Chen Jun

    2006-01-01

    Objective: To evaluate the early results and mid-term outcomes following angioplasty of vertebro-basilar arterial stenosis with drug-eluting stents. Methods: All of the patients presented with recurrent TIA or ceretral infarction with >50% stenoses in vertebro-basilar arteries, and having failure in maximal medical therapy. All of the lesions were treated with primary stenting under local or general anesthesia and followed by continual anticoagulant therapy of clopidogrel and aspirin together with clinical follow-up and vascular imagings. Results: Of 28 stenoses (27 patients), 27 lesions were successfully treated with implantation of 24 Cypher stents, 2 Taxus stents and one Firebird stent. The mean stenotic severity reduced from (74 ± 6.7)% to (8.7 ± 4.4)%. Two patients had inchemic events relating to penetration vascular obstruction. During 2-14 months follow-up, the patients were clinically asymptomatic with no recurrent TIA/stoke. Angiographic follow-up was obtained in 14 patients at a mean of 7.2 months. Proximal restenosis (<50%) occurred in one patient (3.3%), and corrected with restenting, while others were free of intra-stent restenoses. Conclusion: Using DES in cerebrovascular stenosis is safe and effective with lowing the risk of intra-stent restenosis in comparison with bare stent. Further study for long term efficiency is still in need. (authors)

  20. Carotid Artery Stenting Successfully Prevents Progressive Stroke Due to Mobile Plaque

    Directory of Open Access Journals (Sweden)

    Masahiro Oomura

    2015-05-01

    Full Text Available We report a case of progressive ischemic stroke due to a mobile plaque, in which carotid artery stenting successfully prevented further infarctions. A 78-year-old man developed acute multiple infarcts in the right hemisphere, and a duplex ultrasound showed a mobile plaque involving the bifurcation of the left common carotid artery. Maximal medical therapy failed to prevent further infarcts, and the number of infarcts increased with his neurological deterioration. Our present case suggests that the deployment of a closed-cell stent is effective to prevent the progression of the ischemic stroke due to the mobile plaque.

  1. High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography - initial experience

    International Nuclear Information System (INIS)

    Rist, Carsten; Nikolaou, Konstantin; Wintersperger, Bernd J.; Reiser, Maximilian F.; Becker, Christoph R.; Flohr, Thomas

    2006-01-01

    The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265±25HU and 254±16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367±36HU versus 402±28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68±0.08 mm versus 2.81±0.07 mm and 3.29±0.06 mm versus 3.18±0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen. (orig.)

  2. Evolution of patency rates of self-expandable bare metal stents for endovascular treatment of femoro-popliteal arterial occlusive disease: Does stent design matter?

    Science.gov (United States)

    Treitl, Karla Maria; Woerner, Benedikt; Schinner, Regina; Czihal, Michael; Notohamiprodjo, Susan; Hoffmann, Ulrich; Treitl, Marcus

    2017-09-01

    To analyse the patency rates of femoro-popliteal stenting with different self-expandable Nitinol stent-designs. Two hundred and twenty-two patients (142 (64%) male; age 72.4 ± 11.6 years) with symptomatic femoro-popliteal peripheral arterial occlusive disease (PAOD) underwent percutaneous transluminal angioplasty (PTA) and stenting with three different Nitinol stents (interwoven IW: n = 70; closed-cell CC: n = 85; open-cell OC: n = 67). One-year post-procedural target lesion revascularization (TLR_12M) rates were investigated with regard to co-morbidities: diabetes (DBM), hyperlipidaemia (HLP), hypertension (RR), coronary artery disease (CAD) and degree of calcification. Twelve-month follow-up data were available for 60, 69 and 50 patients in the IW, OC and CC groups (179 patients in total). The cumulative patency (IW: 52 (86.7%); OC: 50 (72.5%); CC: 23 (46.0%); P stent and the highest TLR_12M for the CC stent. The interwoven stent-design was superior to the standard open- and closed-cell stent-designs in endovascular treatment of femoro-popliteal PAOD in a follow-up period of 12 months. • Results of femoro-popliteal stenting are still unsatisfactory. • Comparative studies for currently available different Nitinol stent-designs are lacking. • This is a first comparative study on long-term patency of different Nitinol stent-designs. • Interwoven stent-design leads to improved long-term patency. • Interwoven stent-design leads to lower TLR than other stent-designs.

  3. Percutaneous coronary intervention with second-generation paclitaxel-eluting stents versus everolimus-eluting stents in United States contemporary practice (REWARDS TLX Trial).

    Science.gov (United States)

    Waksman, Ron; Ghali, Magdi; Goodroe, Randy; Ryan, Thomas; Turco, Mark; Ring, Michael; McGarry, Thomas; Dobies, David; Shammas, Nicolas; Steinberg, Daniel H; Swymelar, Stacy; Kaneshige, Kimberly; Torguson, Rebecca

    2012-10-15

    Registry Experience at the Washington Hospital Center, DES - Taxus Liberte Versus Xience V (REWARDS TLX) is a physician-initiated, retrospective, real-world, multicenter, observational study for all patients >18 years of age subjected to percutaneous coronary intervention with everolimus-eluting stents (EESs) or paclitaxel-eluting stents (PESs). Outcomes of patients receiving a TAXUS Liberté or XIENCE V drug-eluting stent were compared. Baseline clinical, procedural, and follow-up data at 12 months were collected from 10 clinical centers by an electronic data capture system. The study's primary end point was major adverse cardiac events: a composite of all-cause death, Q-wave myocardial infarction, target vessel revascularization, and stent thrombosis. The trial is registered with http://www.clinicaltrials.gov (NCT01134159). Data were entered for 1,195 patients (PES, n = 595; EES, n = 600). Baseline clinical characteristics were similar except for higher dyslipidemia, systemic hypertension, and family history of coronary artery disease in the EES group. In-hospital outcome was similar between groups, with an overall in-hospital stent thrombosis rate of 0.2%. The primary end point at 12 months was similar (EES 7.8% vs 10.8%, p = 0.082). Overall stent thrombosis rate was lower in the EES group (0.3% vs 1.2%, respectively, p = 0.107); however, target lesion revascularization was similar (PES, hazard ratio 1.46, 95% confidence interval 0.98 to 2.19, p = 0.064). There was no difference in overall mortality between groups. In conclusion, second-generation EESs and PESs demonstrated similar efficacy and safety profiles for broadened patient and lesion subsets compared to a selected population from the pivotal trials. However, for composite efficacy and safety end points, EESs outperformed second-generation PESs. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Stenting of the cervical internal carotid artery in acute stroke management: The Karolinska experience.

    Science.gov (United States)

    Mpotsaris, Anastasios; Kabbasch, Christoph; Borggrefe, Jan; Gontu, Vamsi; Soderman, Michael

    2017-04-01

    Background Emergency stent placement in the extracranial internal carotid artery in combination with anterior circulation thrombectomy is a routine procedure. Yet, precise indications and clinical safety in this setting remains controversial. Present data for mechanical thrombectomy include few studies with acute stenting of tandem occlusions. We evaluated the feasibility, safety and clinical outcome of this endovascular treatment in a retrospective analysis of all consecutive cases at a comprehensive stroke centre. Methods This was a retrospective analysis of all consecutive patients with acute extracranial carotid artery occlusion including acute dissection or high-grade stenosis and concomitant intracranial large-vessel occlusion treated with emergency carotid stenting and intracranial mechanical thrombectomy between November 2007 and May 2015. Results A total of 63 patients with a median age of 67 years (range 33-84 years) were treated. Of these, 33 (52%) patients had concomitant intravenous thrombolysis with recombinant tissue-type plasminogen activator initially. Median admission National Institutes of Health Stroke Scale was 14 (range 1-29). Median time from stroke onset to recanalization was 408 minutes (range 165-1846 minutes). Procedure time was significantly shorter after intravenous thrombolysis (110 minutes [range 15-202 minutes] vs. 130 minutes [range 60-280 minutes]; p = 0.02). Three (5%) patients experienced post-procedural symptomatic intracerebral haemorrhage. In 55/63 (87%) patients, a score of ≥2b on the Thrombolysis in Cerebral Infarction scale could be achieved. Eight (13%) patients died, five (8%) during the acute phase. A total of 29/63 (46%) patients showed a favourable outcome (modified Rankin Scale score of 0-2) after three months. Conclusions Our single-centre retrospective analysis of emergency stent placement in the extracranial internal carotid artery in combination with anterior circulation thrombectomy demonstrated high

  5. Interventional Management of Delayed and Massive Hemobilia due to Arterial Erosion by Metallic Biliary Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hee Seok [Dept. of Radiology, Gyeongsang National University Hospital, Jinju (Korea, Republic of); Shin, Tae Beom [Dept. of Diagnostic Radiology, Kimhae Jung Ang Hospital, Kimhae (Korea, Republic of); Hwang, Jae Cheol [Dept. of Radiology, Ulsan Hospital, Ulsan (Korea, Republic of); Bae, Jae Ik [Dept. of Radiology, Ajou University Hospital, Suwon (Korea, Republic of); Kim, Chang Won [Dept. of Radiology, Busan National University Hospital, Busan (Korea, Republic of)

    2012-01-15

    To evaluate the effectiveness of interventional management for delayed and massive hemobilia secondary to arterial erosion self expandable metallic stent (SES) in with biliary duct malignancy. Over 8-year period, eight patients who suffered from delayed massive hemobilia after SES placement for malignant biliary obstruction as palliative procedure, were included. The mean period between SES placement and presence of massive gastrointestinal hemorrhage was 66.5 days (15-152 days), pancreatic cancer (n = 2), Klatskin tumor (n = 2), common bile duct cancer (n = 2), intrahepatic cholangiocarcinoma (n = 1), and gastric cancer with ductal invasion (n = 1). Angiographic findings were pseudoaneurysm (n = 6), contrast extravasation (n = 1) and arterial spasm at segment (n = 1). Six patients underwent embolization of injured vessels using microcoils and N-butyl cyanoacrylate. Two patients underwent stent graft placement at right hepatic artery to prevent ischemic hepatic damage because of the presence of portal vein occlusion. Massive hemobilia was successfully controlled by the embolization of arteries (n = 6) and stent graft placement (n = 2) without related complications. The delayed massive hemobilia to arterial erosion metallic biliary stent is rare this complication be successfully treated by interventional management.

  6. Efficacy of different types of self-expandable stents in carotid artery stenting for carotid bifurcation stenosis.

    Science.gov (United States)

    Liu, Ya-min; Qin, Hao; Zhang, Bo; Wang, Yu-jing; Feng, Jun; Wu, Xiang

    2016-02-01

    Both open and closed loop self-expandable stents were used in carotid artery stenting (CAS) for carotid bifurcation stenosis. We sought to compare the efficacy of two types of stents in CAS. The data of 212 patients treated with CAS (42 and 170 cases implanted with closed and open loop stents, respectively) for carotid bifurcation stenosis and distal filtration protection devices were retrospectively analyzed. Between closed and open loop stents, there were no significant differences in hospitalization duration, NIHSS score before and after the treatment, stenosis at 12th month, and cumulative incidence of primary endpoint events within 30 days or from the 31st day to the 12th month; while there were significant differences in hemodynamic changes and rate of difficulty in recycling distal filtration protection devices. Use of open vs. closed loop stents for carotid bifurcation stenosis seems to be associated with similar incidence of complications, except for greater rate of hemodynamic changes and lower rate of difficulty in recycling the distal filtration protection devices.

  7. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    International Nuclear Information System (INIS)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.

    2003-01-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  8. Results of a randomized clinical trial of external beam radiation to prevent restenosis after superficial femoral artery stenting.

    Science.gov (United States)

    Therasse, Eric; Donath, David; Elkouri, Stéphane; Lespérance, Jacques; Giroux, Marie-France; Oliva, Vincent L; Guertin, Marie-Claude; Bouchard, Louis; Perreault, Pierre; Gilbert, Patrick; Soulez, Gilles

    2016-06-01

    The objective of this study was to evaluate the safety and efficacy of external beam radiation (EBR) in preventing restenosis after superficial femoral artery (SFA) stenting in comparison with a control group treated with SFA stenting only. In this Institutional Review Board-approved study, patients who provided written informed consent were randomly assigned to 0 Gy or 14 Gy of EBR to the stent site 24 hours after SFA stenting. The primary end point was the angiographic binary restenosis rate 2 years after stenting. Categorical and continuous end points were respectively analyzed using logistic regression models and Wilcoxon tests. End points expressed as time to event were analyzed using a log-rank test. The study included 155 patients, 46 women and 109 men (mean age, 66 years; range, 45-85 years). In the 0 and 14 Gy groups, binary restenosis was present, respectively, in 44% (34/77) and 68% (52/76; P = .003) 2 years after stenting. Stent thrombosis occurred in 13% (10/78) of the 0 Gy group and in 33% (25/77) of the 14 Gy group (P = .003). Target lesion revascularization at 2 years was 26% (25/78) in the 0 Gy group and 30% (23/77) in the 14 Gy group (P = .56). There were no significant differences in total walking distances change from baseline to 2 years (46 ± 100 and 26 ± 79 m, respectively, in the 0 Gy and 14 Gy group; P = .25). There were no procedure-related deaths and no major amputations. A single 14 Gy dose of EBR to the SFA stenting site did not prevent in-stent restenosis. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. Enterprise stent in recanalizing non-acute atherosclerotic intracranial internal carotid artery occlusion.

    Science.gov (United States)

    Wang, Xiaofei; Wang, Zhigang; Ji, Yong; Ding, Xuan; Zang, Yizheng; Wang, Chengwei

    2017-11-01

    To investigate the safety and effectiveness of recanalization in non-acute occlusion of intracranial internal carotid arteries using the flexible Enterprise self-expanding stent. From June 2014 to June 2016, 12 consecutive patients with non-acute occlusion of intracranial internal carotid arteries received endovascular recanalization with Enterprise stenting. All patients received medication for anti-platelet aggregation therapy before and after the operation. The perioperative complications and recanalization efficacy were evaluated with the modified Rankin scoring system and digital subtraction angiography (DSA) follow-up, respectively. Endovascular recanalization was successfully performed in 10 out of 12 patients with Enterprise stenting. Stent implantation following balloon dilatation failed in one patient because the lumen diameter was too small. Another recanalization failed because the guide wire could not pass through the occlusion. No perioperative mortality was observed. One case of acute thrombosis and one case of intraoperative carotid spasm occurred, but these were resolved with thrombolytic therapy by microcatheter exposure treatment and antispasmodic medications, respectively. DSA follow-up in seven patients revealed no re-occlusion. One stroke event occurred in the 10 patients who completed the follow-up. A meaningful improvement in the modified Rankin score during follow-up was suggested by Wilcoxon signed-rank test results. The Enterprise stent was shown to be safe and efficient in recanalizing non-acute atherosclerotic intracranial internal carotid artery occlusion. However, the long-term outcomes need to be further investigated. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Efficacy and safety of catheter-based radiofrequency renal denervation in stented renal arteries.

    Science.gov (United States)

    Mahfoud, Felix; Tunev, Stefan; Ruwart, Jennifer; Schulz-Jander, Daniel; Cremers, Bodo; Linz, Dominik; Zeller, Thomas; Bhatt, Deepak L; Rocha-Singh, Krishna; Böhm, Michael; Melder, Robert J

    2014-12-01

    In selected patients with hypertension, renal artery (RA) stenting is used to treat significant atherosclerotic stenoses. However, blood pressure often remains uncontrolled after the procedure. Although catheter-based renal denervation (RDN) can reduce blood pressure in certain patients with resistant hypertension, there are no data on the feasibility and safety of RDN in stented RA. We report marked blood pressure reduction after RDN in a patient with resistant hypertension who underwent previous stenting. Subsequently, radiofrequency ablation was investigated within the stented segment of porcine RA, distal to the stented segment, and in nonstented RA and compared with stent only and untreated controls. There were neither observations of thrombus nor gross or histological changes in the kidneys. After radiofrequency ablation of the nonstented RA, sympathetic nerves innervating the kidney were significantly reduced, as indicated by significant decreases in sympathetic terminal axons and reduction of norepinephrine in renal tissue. Similar denervation efficacy was found when RDN was performed distal to a renal stent. In contrast, when radiofrequency ablation was performed within the stented segment of the RA, significant sympathetic nerve ablation was not seen. Histological observation showed favorable healing in all arteries. Radiofrequency ablation of previously stented RA demonstrated that RDN provides equally safe experimental procedural outcomes in a porcine model whether the radiofrequency treatment is delivered within, adjacent, or without the stent struts being present in the RA. However, efficacious RDN is only achieved when radiofrequency ablation is delivered to the nonstented RA segment distal to the stent. © 2014 American Heart Association, Inc.

  11. Use of a Stent Graft for Bleeding Hepatic Artery Pseudoaneurysm Following Pancreaticoduodenectomy

    Directory of Open Access Journals (Sweden)

    Leoncio L. Kaw, Jr

    2006-10-01

    Full Text Available Although uncommon, bleeding following pancreaticoduodenectomy is associated with high mortality. Management generally includes surgical reexploration or, alternatively, transarterial embolization. We report the case of a 62-year-old man who presented with massive upper gastrointestinal bleeding 3 weeks after pancreaticoduodenectomy. Selective coeliac angiography revealed a large pseudoaneurysm involving the proper hepatic artery. This was treated successfully with a stent graft. There was no recurrence of bleeding at the 6-month follow-up. To our knowledge, this is the first report of stent graft repair of bleeding hepatic artery pseudoaneurysm following pancreaticoduodenectomy.

  12. Efficacy of Carotid Artery Stenting by the Universal Protection Method.

    Science.gov (United States)

    Goto, Shunsaku; Ohshima, Tomotaka; Kato, Kyozo; Izumi, Takashi; Wakabayashi, Toshihiko

    2018-04-18

    To avoid distal plaques embolization during carotid artery stenting, we developed Universal Protection Method that combined the use of a proximal common carotid artery balloon, an external carotid artery balloon, and a distal internal carotid artery filter, with continuous flow reversal to the femoral vein. Herein, we assessed the efficacy of the Universal Protection Method by comparing stenting outcomes before and after its introduction. We assessed outcomes for 115 cases before and 41 cases after the Universal Protection Method was adopted (non-Universal Protection Method and Universal Protection Method groups, respectively). We then compared procedure details, magnetic resonance imaging (within 48 hours after the procedure), intraprocedural complications, and postoperative stroke rates. Ischemic stroke was not observed in the Universal Protection Method group, but 1 major stroke and 2 minor strokes were observed in the non-Universal Protection Method group. High-intensity areas were seen in 6 (15.0%) and 49 (42.6%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively (P = .001). Contrastingly, intraprocedural complications were observed in 9 (22.5%) and 21 (18.3%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively. Among these intraprocedural complication cases, high-intensity areas were observed in 1 case (11.1%) in the Universal Protection Method group and in 15 cases (71.4%) in the non-Universal Protection Method group. Universal Protection Method is a safe technique that is applicable to all patients undergoing carotid artery stenting, irrespective of individual risk factors. Notably, the incidence rates of both distal embolization and unexpected intraprocedural complications are low. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  13. Prognostic value of renal fractional flow reserve in blood pressure response after renal artery stenting (PREFER study).

    Science.gov (United States)

    Kądziela, Jacek; Januszewicz, Andrzej; Prejbisz, Aleksander; Michałowska, Ilona; Januszewicz, Magdalena; Florczak, Elżbieta; Kalińczuk, Łukasz; Norwa-Otto, Bożena; Warchoł, Ewa; Witkowski, Adam

    2013-01-01

    The aim of our study was to determine a potential relationship between resting translesional pressures ratio (Pd/Pa ratio), renal fractional flow reserve (rFFR) and blood pressure response after renal artery stenting. Thirty five hypertensive patients (49% males, mean age 64 years) with at least 60% stenosis in angiography, underwent renal artery stenting. Translesional systolic pressure gradient (TSPG), Pd/Pa ratio (the ratio of mean distal to lesion and mean proximal pressures) and hyperemic rFFR - after intrarenal administration of papaverine - were measured before stent implantation. Ambulatory blood pressure measurements (ABPM) were recorded before the procedure and after 6 months. The ABPM results were presented as blood pressure changes in subgroups of patients with normal (≥ 0.9) vs. abnormal (renal artery stenting. Median changes of 24-h systolic/diastolic blood pressure were comparable in patients with abnormal vs. normal Pd/Pa ratio (-4/-3 vs. 0/2 mm Hg; p = NS) and with abnormal vs. normal rFFR (-2/-1 vs. -2/-0.5 mm Hg, respectively). Physiological assessment of renal artery stenosis using Pd/Pa ratio and papaverine- induced renal fractional fl ow reserve did not predict hypertension response after renal artery stenting.

  14. Stent-protected angioplasty versus carotid endarterectomy in patients with carotid artery stenosis: meta-analysis of randomized trial data

    International Nuclear Information System (INIS)

    Wiesmann, Martin; Schoepf, Veronika; Brueckmann, Hartmut; Jansen, Olav

    2008-01-01

    Stent-protected angioplasty of carotid artery stenosis may be an alternative to surgical endarterectomy. Results published so far are indecisive, with evidence both in favour of and against this procedure. After the recent publication of two large European multicentre trials (SPACE and EVA-3S) almost 3,000 patients have been included in randomized studies. For this report, we therefore conducted a systematic review of randomized studies that compared endovascular treatment with surgery for carotid stenosis. We evaluated seven trials including 2,973 patients. In our meta-analysis endovascular treatment seemed to carry a slightly higher risk for stroke or death within 30 days after the procedure as compared with surgery (8.2% vs. 6.2%; p = 0.04; OR 1.35), whereas the rates of disabling stroke or death within 30 days did not differ significantly (p = 0.47; n.s.). On the other hand, surgery carried a significantly higher risk for cranial nerve palsy (4.7% vs. 0.2%; p < 0.0001; OR 0.17) and myocardial infarction (2.3% vs. 0.9%; p = 0.03; OR 0.37). Long-term effects of both methods still need to be evaluated. Two other large multicentre trials (ICSS and CREST) are ongoing. Results of these studies will increase the database to about 7,000 randomized patients. Future meta-analyses should then allow definitive treatment recommendations. (orig.)

  15. One Year Clinical Outcomes of Renal Artery Stenting: The Results of ODORI Registry

    International Nuclear Information System (INIS)

    Sapoval, M.; Tamari, I.; Goffette, P.; Downes, M.; Senechal, Q.; Fanelli, F.; Reimer, P.; Negaiwi, Z.; Cassin, P. De; Heye, S.; Korobov, V.; Tsetis, D.; Abada, H.

    2010-01-01

    The safety, efficacy and long term clinical benefits of renal artery revascularization by stenting are still a matter of debate. The aim of our study was to define the safety and efficacy of renal artery stenting with the Tsunami peripheral stent (Terumo Corporation, Tokyo, Japan). The ODORI was a prospective, multicentre registry which enrolled 251 consecutive patients, (276 renal arteries) in 36 centres across Europe. The primary endpoint was acute procedural success defined as <30% residual stenosis after stent placement. Secondary endpoints included major adverse events, blood pressure control, serum creatinine level, and target lesion revascularization (TLR) at 6 and 12 months. Patients were 70 ± 10 years old, 59% were male, 33% had diabetes, and 96% hypertension. The main indications for renal stent implantation were hypertension in 83% and renal salvage in 39%. Direct stent implantation was performed in 76% of the cases. Acute success rate was 100% with residual stenosis of 2.5 ± 5.4%. Systolic/diastolic blood pressure decreased from a mean of 171/89 at baseline to 142/78 mmHg at 6 months (p < 0.0001 vs. baseline), and 141/80 mmHg at 12 months (p < 0.0001 vs. baseline). Mean serum creatinine concentration did not change significantly in the total population. However, there was significant improvement in the highest tercile (from 283 μmol/l at baseline to 205 and 209 μmol/l at 6 and 12 months respectively). At 12-months, rates of restenosis and TLR were 6.6 and 0.8% respectively. The 12 month cumulative rate of all major clinical adverse events was 6.4% while the rate of device or procedure related events was 2.4%. In hypertensive patients with atherosclerotic renal artery stenosis Tsunami peripheral balloon-expandable stent provides a safe revascularization strategy, with a potential beneficial impact on hypertension control and renal function in the highest risk patients.

  16. Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: Prospective comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Li Xiaoming; Li Yuhua; Tian Jianming; Xiao Yi; Lu Jianping; Jing Zaiping; Sheng Jing; Edwin, Angela; Wu Fanghong

    2010-01-01

    Purpose: To assess the accuracy of 64-slice multi-detector row computed tomography (MDCT) angiography in the evaluation of peripheral artery in-stent or peristent restenosis, with conventional digital subtraction angiography (DSA) as the reference standard. Materials and methods: Forty-one patients (30 men, 11 women; mean age, 69.8 ± 9.2 years) with symptomatic peripheral arterial occlusive disease after peripheral artery stenting (81 stented lesions) underwent both conventional DSA and 64-slice MDCT angiography. Each stent was classified as evaluable or unevaluable, and every stent was divided into three segments (proximal stent, stent body, and distal stent), resulting in 243 segments. For evaluation, stenosis was graded as follows: 1, none or slight stenosis (<25%); 2, mild stenosis (25-49%); 3, moderate stenosis (50-74%); 4, severe stenosis or total occlusion (≥75%). Two readers evaluated all CT angiograms with regard to narrowing of in-stent or peristent restenosis by consensus. Results were compared with findings of the DSA. Results: Of 81 stents, 62 (76.5%) were determined to be assessable. The metal artifact of the gold marker and motion artifact increased uninterpretability of the images of stents. Overall, 24 of 28 in-stent restenosis and 38 of 53 persistent restenosis were correctly detected by MDCT (85.7% and 71.7% sensitivity). In evaluable stents, 21 of 22 in-stent restenoses and 27 of 28 persistent restenosis were correctly detected (95.4% and 96.4% sensitivity). Additionally, as the grade of stenosis increases, the mean level of CT values in the stent lumina decreases linearly accordingly. Conclusion: 64-Slice MDCT has a high accuracy for the detection of significant in-stent or peristent restenosis of assessable stents in patients with peripheral artery stent implantation and therefore can be considered as a valuable noninvasive technique for stent surveillance.

  17. A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1-year analysis of clinical and procedural secondary outcomes from a randomised controlled trial

    NARCIS (Netherlands)

    Serruys, Patrick W.; Chevalier, Bernard; Dudek, Dariusz; Cequier, Angel; Carrié, Didier; Iniguez, Andres; Dominici, Marcello; van der Schaaf, René J.; Haude, Michael; Wasungu, Luc; Veldhof, Susan; Peng, Lei; Staehr, Peter; Grundeken, Maik J.; Ishibashi, Yuki; Garcia-Garcia, Hector M.; Onuma, Yoshinobu

    2015-01-01

    Despite rapid dissemination of an everolimus-eluting bioresorbable scaffold for treatment for coronary artery disease, no data from comparisons with its metallic stent counterpart are available. In a randomised controlled trial we aimed to compare an everolimus-eluting bioresorbable scaffold with an

  18. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong Suk, E-mail: hongsukpark@gmail.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Do, Young Soo, E-mail: ysdo@skku.edu [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Kim, Duk-Kyung, E-mail: dukkyung.kim@samsung.com [Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, Sung Wook, E-mail: sw.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Shin, Sung Wook, E-mail: sw88.shin@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Cho, Sung Ki, E-mail: sungkismc@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Hyun, Dongho, E-mail: mesentery.hyun@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, In Wook, E-mail: inwook.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of)

    2013-11-01

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure.

  19. Dual-artery stenting of a type III single coronary artery from right aortic sinus

    Directory of Open Access Journals (Sweden)

    Shivanad Patil

    2015-12-01

    Full Text Available A single coronary artery presenting with stenosis in two of the three vessels arising from a common ostium is a rare anomaly Lipton et al. proposed a classification, which was modified by Yamanaka and Hobbs. In our case, a single coronary artery was giving rise to the LAD, left circumflex (LCx, and the right coronary artery (RCA. There was 80% stenosis in the ostium of the LCx. The RCA in the mid and distal segment had stenosis of 80% and 70%, respectively. We were able to successfully stent the three stenotic segments.

  20. Stent implantation for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation

    International Nuclear Information System (INIS)

    Xing Ming; Yang Pengfei; Huang Qinghai; Zhao Wenyuan; Hong Bo; Xu Yi; Liu Jianmin

    2012-01-01

    Objective: To preliminarily evaluate the feasibility, safety and efficacy of stent placement for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation. Methods: Eleven patients with wide-necked aneurysms located at internal carotid artery bifurcation, who were encountered during the period from Jan. 2004 to Dec. 2010 in hospital, were collected. A total of 16 intracranial aneurysms were detected, of which 11 were wide-necked and were located at internal carotid artery bifurcation. The diameters of the aneurysms ranged from 2.5 mm to 18 mm. Individual stent type and stenting technique was employed for each patient. Follow-up at 1, 3, 6 and 12 months after the procedure was conducted. Results: A total of 11 different stents were successfully deployed in the eleven patients. The stents included balloon expandable stent (n=1) and self-expanding stent (n=10). According to Raymond grading for the immediate occlusion of the aneurysm, grade Ⅰ (complete obliteration) was obtained in 4, grade Ⅱ (residual neck) in 2 and grade Ⅲ (residual aneurysm) in 5 cases. No procedure-related complications occurred. At the time of discharge, the modified Rankin score was 0-1 in the eleven patients. During the follow-up period lasting for 1-108 months, all the patients were in stable condition and no newly-developed neurological dysfunction or bleeding observed. Follow-up examination with angiography (1-48 months) showed that the aneurysms were cured (no visualization) in 4 cases, improved in 2 cases and in stable condition in one case. Conclusion: For the treatment of wide-necked aneurysms located at internal carotid artery bifurcation, stent implantation is clinically feasible, safe and effective. Further studies are required to evaluate its long-term efficacy. (authors)

  1. Fibrosing Mediastinitis: Successful Stenting of the Pulmonary Artery

    Directory of Open Access Journals (Sweden)

    Rennae Thiessen

    2008-01-01

    Full Text Available Fibrosing mediastinitis is a rare benign condition, which can cause compression of the pulmonary or systemic vessels, tracheobronchial tree, coronary arteries or esophagus, leading to disabling clinical symptoms and even death. The case of a 26-year-old woman who presented with dyspnea is described. She was found to have 80% stenosis of the right pulmonary artery secondary to fibrosing mediastinitis. The stenosis was managed successfully with an endovascular Palmaz-Schatz stent, and the patient remains symptom-free 10 years later.

  2. Stent-Graft Repair of a Large Cervical Internal Carotid Artery Pseudoaneurysm Causing Dysphagia

    International Nuclear Information System (INIS)

    Gupta, Vivek; Niranjan, Khandelwal; Rawat, Lokesh; Gupta, A. K.

    2009-01-01

    Pseudoaneurysms of the cervical internal carotid artery (ICA) are rare and most frequently result from trauma, infection, or sometimes spontaneously. They have the potential to cause life-threatening hemorrhage; thus, their immediate management is necessary. Endovascular treatment by stent graft placement in the affected artery appears to be a safe and effective treatment option. We present a case of a child who presented with neck swelling and dysphagia caused by a ruptured cervical ICA pseudoaneurysm which was managed by stent graft placement.

  3. Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

    Energy Technology Data Exchange (ETDEWEB)

    Ichihashi, Shigeo, E-mail: shigeoichihashi@yahoo.co.jp; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko [Nara Medical University, Department of Radiology (Japan)

    2012-12-15

    We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

  4. Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

    International Nuclear Information System (INIS)

    Ichihashi, Shigeo; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko

    2012-01-01

    We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

  5. Massive Bleeding from Guidewire Perforation of an External Iliac Artery: Treatment with Hand-made Stent-Graft Placement

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, Vimal, E-mail: drvimalmehta@yahoo.co.in; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay [G.B. Pant Institute of Postgraduate Medical Education and Research (India)

    2016-01-15

    We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory.

  6. Massive Bleeding from Guidewire Perforation of an External Iliac Artery: Treatment with Hand-made Stent-Graft Placement

    International Nuclear Information System (INIS)

    Mehta, Vimal; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay

    2016-01-01

    We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory

  7. Incremental benefit of three-dimensional transesophageal echocardiography in the assessment of left main coronary artery stent protrusion.

    Science.gov (United States)

    Arisha, Mohammed J; Hsiung, Ming C; Ahmad, Amier; Nanda, Navin C; Elkaryoni, Ahmed; Mohamed, Ahmed H; Yin, Wei-Hsian

    2017-06-01

    Ostial lesions represent a challenging clinical scenario and percutaneous intervention (PCI) of left main coronary artery ostial lesions has been associated with postintervention complications, including protrusion of deployed stents into a sinus of Valsalva or aortic root. We report a case of stent protrusion into the aortic root following aorto-ostial left main coronary artery PCI, in which three-dimensional transesophageal echocardiography (3DTEE) provided incremental benefit over standard two-dimensional images. Specifically, 3DTEE confirmed the presence of stent protrusion by allowing clear visualization of the stent scaffold, in addition to characterizing the relationship between the stent and surrounding structures. © 2017, Wiley Periodicals, Inc.

  8. Surgical treatment of massive bleeding of a right aberrant subclavian artery after oesophageal stent removal

    Directory of Open Access Journals (Sweden)

    Michael Raum

    2018-06-01

    Full Text Available We report a case of a 9-year-old female who required surgical treatment and resuscitation after severe transoesophageal bleeding of a right aberrant subclavian artery (RASA. Bleeding of this RASA was caused by a mechanical irritation due to an oesophageal stent. The stent was placed weeks before to dilate the oesophagus after accidental ingestion of a caustic agent. Although conservative management of benign oesophageal stenosis in children is highly recommended, there are still some major complications to be considered. To avoid erosion of aberrant subclavian artery vascular rings and slings, as described in several case reports, these vessels should be excluded by computed tomography (CT or magnetic resonance imaging (MRI scans before placement of oesophageal stents. This case suggests that management of caustic ingestion in children is still a major challenge in paediatric surgical departments. Keywords: Paediatric surgery, Chemical Burn, Oesophageal stenosis, Oesophageal stenting, Vascular abnormalities, Right aberrant subclavian artery

  9. Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial

    Energy Technology Data Exchange (ETDEWEB)

    Lammer, Johannes, E-mail: jlammer@gmx.at, E-mail: johannes.lammer@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); Zeller, Thomas, E-mail: thomas.zeller@universitaets-herzzentrum.de [Universitaets-Herzzentrum Freiburg-Bad Krozingen, Department of Angiology (Germany); Hausegger, Klaus A., E-mail: klaus.hausegger@lkh-klu.at [Klinikum Klagenfurt, The Department of Diagnostic and Interventional Radiology (Austria); Schaefer, Philipp J., E-mail: jp.schaefer@rad.uni-kiel.de [University Clinics Schleswig-Holstein, The Department of Radiology (Germany); Gschwendtner, Manfred, E-mail: manfred.gschwendtner@elisabethinen.or.at [Elisabethinen Hospital, The Department of Diagnostic and Interventional Radiology (Austria); Mueller-Huelsbeck, Stefan, E-mail: muehue@diako.de [Diakonissen Hospital, The Department of Diagnostic and Interventional Radiology (Germany); Rand, Thomas, E-mail: thomas.rand@wienkav.at [Hietzing Hospital, The Department of Radiology (Austria); Funovics, Martin, E-mail: martin.funovics@meduniwien.ac.at; Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); Rastan, Aljoscha, E-mail: aljoscha.rastan@universitaets-herzzentrum.de [Universitaets-Herzzentrum Freiburg-Bad Krozingen, Department of Angiology (Germany); Gschwandtner, Michael, E-mail: michael.gschwandtner@meduniwien.ac.at [Medical University Vienna, The Department of Angiology (Austria); Puchner, Stefan, E-mail: stefan.puchner@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); and others

    2015-02-15

    PurposeThe hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only.MethodsA prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN{sup ®} Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN{sup ®} versus 17.3 ± 6.6 cm in the BMS group.ResultsThe 24-month primary patency rates in the VIABAHN{sup ®} and BMS group were: intention-to-treat 63.1 (95 % CI 0.52–0.76) versus 41.2 % (95 % CI 0.29–0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58–0.83) versus 40.0 % (95 % CI 0.28–0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70–0.90) versus 73.0 % (95 % CI 0.63–0.85) for VIABAHN{sup ®} versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50–0.85) versus 26.7 % (95 % CI 0.12–0.59; log rank p = 0.004) for VIABAHN{sup ®} versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68–0.94) versus 61.9 % (95 % CI 0.44–0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN{sup ®} versus the BMS group, respectively.ConclusionAt 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244)

  10. Vertebral artery origin stent placement with distal protection: technical and clinical results.

    Science.gov (United States)

    Qureshi, A I; Kirmani, J F; Harris-Lane, P; Divani, A A; Ahmed, S; Ebrihimi, A; Al Kawi, A; Janjua, N

    2006-05-01

    To report the feasibility, safety, and 1-month results of performing stent placement for vertebral origin stenosis with the use of a distal protection device. Distal protection devices have been shown to reduce the number of cerebral emboli and subsequent ischemic events when used as adjuncts to percutaneous carotid intervention; however, one case of the use of a distal protection device for vertebral artery has been reported in the literature. We retrospectively determined rates of technical success and 1-month stroke or death associated with stent placement by using distal protection (Filter EX; Boston Scientific, Natick, Mass) in patients with symptomatic vertebral artery origin stenosis. Technical success was defined as successful deployment of distal protection device and stent at target lesion followed by successful retrieval of the device and a final residual stenosis of less than 30%. Other outcomes ascertained included any stroke, death, and semiquantitative assessment of particulate material retained by the filter device. The mean age of the 12 treated patients was 68 years (range, 52-88 years) and the group included 9 men and 3 women. The mean percentage of vertebral artery origin stenosis was 71 +/- 6%. Femoral and radial approaches were used in 9 and 3 cases, respectively. Technical success was achieved in 11 of the 12 patients in whom distal protection device placement was attempted. Postprocedure residual stenosis was 5 +/- 4%. Eight devices held macroscopically visible embolic debris (large and small amounts in 3 and 5 devices, respectively). No stroke or death was observed in the 1-month follow-up. The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a distal protection device. Further studies are required to determine the effectiveness of this approach for vertebral artery origin atherosclerosis.

  11. Stent placement with the monorail technique for treatment of mesenteric artery stenosis.

    Science.gov (United States)

    Schaefer, Philipp J; Schaefer, Fritz K W; Hinrichsen, Holger; Jahnke, Thomas; Charalambous, Nikolas; Heller, Martin; Mueller-Huelsbeck, Stefan

    2006-04-01

    To analyze the immediate and midterm success of stenting of mesenteric arteries by a monorail technique in patients with chronic mesenteric ischemia. In this prospective case series, 19 patients (11 male, 8 female; mean age, 62.9 +/- 10.4 y; range, 36-82 y) with 23 symptomatic stenoses of mesenteric arteries were treated with stent placement by a monorail technique in a radiologic intervention center over a period of 4.5 years. Clinical examinations and duplex sonography were used to evaluate the stents' patency and clinical success. Kaplan-Meier graphs were calculated to analyze the patency and freedom-from-symptom rate. Initial technical success rate was 22/23 (96%). Mean follow-up was 17 months (range, 1-58 mo). Primary patency and primary clinical success rates were 82% and 78%, respectively. According to Kaplan-Meier tables, the patency rates were 96%, 87%, 76%, and 61% at 0, 1, 15, and 24 months, respectively, and the freedom-from-symptom rates were 95%, 90%, 72%, and 54% at 0, 1, 24, and 30 months, respectively. No peri-interventional complications occurred. Two patients died of cardiac failure in the hospital within 30 days after intervention; deaths were not related to the intervention. Stent placement by a monorail technique in mesenteric arteries is an effective and safe treatment for symptomatic stenoses in patients with chronic mesenteric ischemia after a mean follow-up of 17 months.

  12. Treatment of internal carotid artery dissections with endovascular stent placement: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Deok Hee; Hur, Seung Ho; Kim, Hyeon Gak; Jung, Seung Mun; Ryu, Dae Sik; Park, Man Soo [Kangnung Hospital, Kangnung (Korea, Republic of)

    2000-03-01

    Extracranial carotid artery dissection may manifest as arterial stenosis or occlusion, or as dissecting aneurysm formation. Anticoagulation and/or antiplatelet therapy is the first-line treatment, but because it is effective and less invasive than other procedures, endovascular treatment of carotid artery dissection has recently attracted interest. We encountered two consecutive cases of trauma-related extracranial internal carotid artery dissection, one in the suprabulbar portion and one in the subpetrosal portion. We managed the patient with suprabulbar dissection using a self-expandable metallic stent and managed the patient with subpetrosal dissection using a balloon-expandable metallic stent. In both patients the dissecting aneurysm disappeared, and at follow-up improved luminal patency was observed.

  13. Outcomes of emergent carotid artery stenting within 6 hours of symptom onset in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Jeong, Won Gi; Yoon, Woong; Yim, Nam Yeol; Jung, Min Young; Jung, Se Hee; Kang, Heoung Keun

    2013-01-01

    To investigate clinical outcomes following the emergent carotid artery stenting for treatment of acute ischemic stroke. Twenty-eight consecutive patients with acute stroke due to atherosclerotic steno-occlusive diseases of extracranial internal carotid artery underwent emergent carotid artery stenting. Of these, 23 patients had tandem intracranial arterial occlusions. Extracranial carotid stenting was successful in all patients. From the 13 patients who underwent intracranial recanalization procedures, successful recanalization occurred in 84.6% (11/13). 57% of patients (16/28) had a good clinical outcome (modified Rankin Scale 0-2) after 3 months. Patients with successful intracranial/extracranial recanalization had a significantly higher rate of good outcome than those without recanalization after 3 months (75% vs. 33%, p = 0.027). Patients without intracranial tandem occlusions had a more favorable clinical outcome than those with intracranial tandem occlusions (100% vs. 48%, p = 0.033). Symptomatic intracerebral hemorrhage occurred in one patient (3.6%). Mortality rate was 0% (0/28) after 3 months. Emergent carotid artery stenting in setting of acute stroke was a safe and effective treatment modality. Successful recanalization (extracranial and intracranial) and absence of intracranial tandem occlusion are significantly associated with a good outcome for our cohort of patients whom undergone emergent carotid artery stenting.

  14. A clinical study on perforator stroke resulting from Wingspan stent angioplasty for symptomatic intracranial artery stenosis

    International Nuclear Information System (INIS)

    Wang Ziliang; Xu Haowen; Li Tianxiao; Zhu Liangfu; Li Zhaoshuo; Xue Jiangyu; Bai Weixing; Li Li; Guan Sheng

    2011-01-01

    Objective: To evaluate the incidence, potential hazards and effective countermeasure for perforator stroke (PS) resulting from stent angioplasty of symptomatic intracranial artery stenosis. Methods: Peri-operation PS complications of 258 patients receiving Gateway balloon-Wingspan stenting for severe symptomatic intracranial stenosis were analyzed. The incidence, clinical course, and prognosis of PS resulting from stenting were recorded. Special attention was given to the anatomical features, clinical manifestation and video materials of patients with PS. χ 2 test was used for statistics. Results: Two hundred and fifty-five patients received stent angioplasty successfully and 7 patients had PS (incidence rate 2.7%). The patients with basilar artery stenosis had a higher incidence of PS resulting from intracranial stenting (6.1%, 4/66) than patients with middle cerebral artery stenosis (2.5%, 3/118) (χ 2 =2.320, P= 0.025). The potential hazards for PS included preoperative perforator stroke adjacent to the stenotic segment and prominent dissection during operation. Six patients presented symptoms after awake from general anaesthesia and one had symptoms 3 hours after stenting. One deteriorated gradually and the others reached the maximum deficit almost at once. At the follow-up of 3 months, 3 patients were disabled and scored one, two, two by mRS respectively. Conclusion: The incidence of PS resulting from intracranial stenting was low and the prognosis was not disastrous. Stenosis at basilar artery and preoperative perforator stroke adjacent to the stenotic segment were potential risk factors for PS complication. Proper maneuver of angioplasty may decrease the incidence of PS and improve the prognosis. (authors)

  15. Carotid Artery Stenting in a Patient With a Continuous-Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Piazza, Michele; Squizzato, Francesco; Grego, Franco; Bottio, Tommaso; Gerosa, Gino; Antonello, Michele

    2016-08-01

    To demonstrate the safety and feasibility of carotid artery stenting (CAS) in a patient with a continuous-flow left ventricular assist device (LVAD). A 54-year-old woman with a LVAD was referred for a 90% stenosis of the right internal carotid artery (ICA). The patient was offered CAS, and oral anticoagulant was not discontinued in the periprocedural period. Because of absent arterial pulses, percutaneous transfemoral access was obtained under ultrasound guidance. Particular attention was paid to cannulation of the innominate artery; a 7-F guiding catheter was advanced from the descending aorta into the innominate artery under road-mapping, avoiding maneuvers in the ascending aorta where the outflow Dacron graft of the LVAD was anastomosed. To avoid cerebral flow modifications, the Angioguard RX was used as the cerebral protection device rather than other devices such as the flow reversal or flow-clamping systems. At this point, CAS was performed in a standard fashion using the 7×30-mm Precise ProRX stent. The computed tomography angiogram at 6 months showed patency of the stented right ICA. With adequate planning, CAS appears feasible in patients with a LVAD. © The Author(s) 2016.

  16. Thirty-day outcomes of direct carotid artery stenting with cerebral protection in high-risk patients

    International Nuclear Information System (INIS)

    Veselka, J.; Cerna, D.; Zimolova, P.; Blasko, P.; Fiedler, J.; Hajek, P.; Maly, M.; Zemanek, D.; Duchonova, R.

    2007-01-01

    Implantation of a carotid artery stent after predilation is a standard approach in the endovascular treatment of carotid artery stenoses. Stenting without predilation may be an alternative approach in a certain subset of patients. The present prospective, single-center registry was designed to evaluate the feasibility and safety of direct carotid artery stenting (DCAS) in high-risk patients. Symptomatic patients with stenosis >50% and asymptomatic patients with stenosis >70% were eligible for enrolment. Criteria for high-risk patients included: need or history of open heart surgery, history of myocardial infarction, multivessel coronary artery disease, left ventricular dysfunction (ejection fraction ≤40%), severe pulmonary or renal disease, significant contralateral carotid disease, previous endarterectomy, and age ≥80 years. All procedures were performed using a filter protection device. Patients underwent complete clinical examination before and after DCAS and at 30-day follow-up. A total of 83 consecutive patients (45 males, 68±9 years, 33% symptomatic) underwent 100 procedures and 103 stents were deployed successfully. The technical success rate of stenting was 100%. Predilation of carotid stenosis was necessary in 1 (1%) procedure. Carotid-artery stenoses before and after DCAS were 80±9% and 7±9%, respectively. The median fluoroscopic time for DCAS was 7 min. The overall rate of in-hospital major adverse cerebrovascular events (death, stroke, myocardial infarction) was 5% (2 minor strokes, 3 transient attacks). There was 1 (1%) minor stroke within the 30-day follow-up. DCAS is feasible and can be performed with an acceptable risk in high-risk patients. (author)

  17. New treatment of iliac artery disease: focus on the Absolute Pro® Vascular Self-Expanding Stent System

    Directory of Open Access Journals (Sweden)

    Gates L

    2013-09-01

    Full Text Available Lindsay Gates, Jeffrey Indes Vascular and Endovascular Surgery, Yale University School of Medicine, New Haven, CT, USA Abstract: Management of iliac artery disease has evolved over the years, from a surgical-only approach to a primarily endovascular-only approach as the first line treatment option. This has been continuously improved upon with the advent of new devices and applied technologies. Most recently in particular, the literature has shown good, reliable outcomes with the use of self-expandable stents in iliac artery atherosclerotic lesions. Nevertheless, no device is without its limitations, and the Absolute Pro® Vascular Self-Expanding Stent System was designed with the intent of overcoming some of the shortcomings of other available stents while maintaining acceptable postprocedural outcomes. Based on preliminary industry-acquired data, it has achieved these goals and appears to be an emergent competitor for the treatment of both focal and complex iliac artery lesions. Keywords: Absolute-Pro®, iliac stent, self-expanding stents, atherosclerotic disease

  18. Self-Expanding Nitinol Renal Artery Stents: Comparison of Safety and Efficacy of Bare Versus Polyzene-F Nanocoated Stents in a Porcine Model

    International Nuclear Information System (INIS)

    Kurz, P.; Stampfl, U.; Christoph, P.; Henn, C.; Satzl, S.; Radeleff, B.; Berger, I.; Richter, G. M.

    2011-01-01

    Objective: To investigate the safety and efficacy of a Polyzene-F nanocoat on new low-profile self-expandable nitinol stents in minipig renal arteries. Materials and Methods: Ten bare nitinol stents (BNS) and 10 stents coated with a 50 nm-thin Polyzene-F coating were randomly implanted into renal arteries of 10 minipigs (4- and 12-week follow-up, 5 animals/group). Thrombogenicity, on-stent surface endothelialization, vessel wall injury, late in-stent stenosis, and peristrut vessel wall inflammation were determined by quantitative angiography and postmortem histomorphometry. Results: In 6 of 10 BNS, >50% stenosis was found, but no stenosis was found in stents with a nanothin Polyzene-F coating. Histomorphometry showed a statistically significant (p < 0.05) different average maximum luminal loss of 55.16% ± 8.43% at 12 weeks in BNS versus 39.77% ± 7.41% in stents with a nanothin Polyzene-F coating. Stents with a nanothin Polyzene-F coating had a significantly (p < 0.05) lower inflammation score after 12 weeks, 1.31 ± 1.17 versus 2.17 ± 0.85 in BNS. The results for vessel wall injury (0.6 ± 0.58 for Polyzene-F-coated stents; 0.72 ± 0.98 for BNS) and re-endothelialization, (1.16 ± 0.43 and 1.23 ± 0.54, respectively) were not statistically significant at 12-week follow-up. No thrombus deposition was observed on the stents at either follow-up time point. Conclusion: Nitinol stents with a nanothin Polyzene-F coating successfully decreased in-stent stenosis and vessel wall inflammation compared with BNS. Endothelialization and vessel wall injury were found to be equal. These studies warrant long-term pig studies (≥120 days) because 12 weeks may not be sufficient time for complete healing; thereafter, human studies may be warranted.

  19. Reperfusion hemorrhage following superior mesenteric artery stenting.

    LENUS (Irish Health Repository)

    Moore, Michael

    2012-02-03

    Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

  20. Metallic stent implantation combined with intra-arterial chemotherapy for the treatment of malignant gastric and duodenal obstruction

    International Nuclear Information System (INIS)

    Cao Jun; Liu Hongqiang; He Yang; Xia Ning; Zhang Honglei; Qiao Delin

    2011-01-01

    Objective: To investigate the clinical effect of metallic stent implantation together with intra-arterial chemotherapy in treating malignant gastric and duodenal obstruction. Methods: A total of 32 patients with malignant gastric and duodenal obstruction were enrolled in this study. The obstructed sites were located at the gastric sinus and pylorus part (n=16), at the gastroduodenal anastomotic stoma (n=6) or at the descending part of duodenum (n=10). Under DSA guidance and with the additional help of endoscopy, a guide-wire was orally placed in the gastroduodenal obstructed site, which was followed by the implantation of the self-expanding metallic stent (Ni-Ti alloy). Postoperative intra-arterial chemotherapy via the tumor-feeding arteries was carried out in 16 patients (dual interventional therapy). The clinical results were analyzed. Results: Successful stent insertion was achieved in all 32 patients (100%). After stent implantation the obstructive symptoms were markedly relieved and the food intake was improved. No serious complications occurred. The median survival time for the 16 patients who had received dual interventional therapy was 9.3 months, while the median survival time for the other 16 patients who had received simple stenting therapy was 5.7 months. Conclusion: For the treatment of inoperable malignant gastroduodenal obstruction, the implantation of metallic self-expanding stents is a technically simple, clinically safe and effective palliative measure. Combined with postoperative intra-arterial chemotherapy, the metal stent implantation can control the tumor growth and elongate the survival time. (authors)

  1. Functional angiography of arteries near the knee joint: Consequences for stent implantation. Funktionsangiographie der kniegelenknahen Arterien: Konsequenzen fuer die Stentimplantation

    Energy Technology Data Exchange (ETDEWEB)

    Zocholl, G; Zapf, S; Schild, H; Thelen, M [Mainz Univ. (Germany, F.R.). Inst. fuer Klinische Strahlenkunde

    1990-12-01

    Angiographic studies of the arteries adjoining the knee in 25 patients show extensive kinking and stenoses of the popliteal artery and less frequently of the distal femoral artery during flexion of the knee joint. This is due to the loss of elasticity with increasing age forcing the vessel into a tortuous course during shortening of the pathway of the popliteal artery with knee flexion. Independent of the principle of the different stents available they probably will not increase the contractility of the stented vessel in the longitudinal axis. It is to expect that after implantation of stents into the original artery kinking will occur predominantly in the original segments of the vessel and at the transitions to the stented segments leading to intimal damage by shear forces thus propagating local progress of atherosclerosis. (orig.).

  2. Dual-Source CT Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Michael Köhler

    2011-01-01

    Full Text Available Purpose. To test different peripheral arterial stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation and image noise in dual-source multidetector row CT (DSCT in vitro. Methods and Materials. 22 stents (nitinol, steel, cobalt-alloy, tantalum, platinum alloy were examined in a vessel phantom. All stents were imaged in axial orientation with standard parameters. Image reconstructions were obtained with four different convolution kernels. To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density and noise were measured. Results. The mean percentage of the visible stent lumen diameter from the nominal stent diameter was 74.5% ± 5.7 for the medium-sharp kernel, 72.8% ± 6.4 for the medium, 70.8% ± 6.4 for the medium-smooth and 67.6% ± 6.6 for the smooth kernel. Mean values of lumen attenuation were 299.7HU ± 127 (medium-sharp, 273.9HU ± 68 (medium, 270.7HU ± 53 (medium-smooth and 265.8HU ± 43. Mean image noise was: 54.6 ± 6.3, 20.5 ± 1.7, 16.3 ± 1.7, 14.0 ± 2 respectively. Conclusion. Visible stent lumen diameter varies depending on stent type and scan parameters. Lumen diameter visibility increases with the sharpness of the reconstruction kernel. Smoother kernels provide more realistic density measurements inside the stent lumen and less image noise.

  3. Impact of diabetes mellitus on outcome of renal artery stenting

    International Nuclear Information System (INIS)

    Song Li; Tong Xiaoqiang; Wang Jian; Yang Min; Lv Yongxing; Zou Yinghua

    2007-01-01

    Objective: To investigate the impact of diabetes mellitus on outcome of renal artery stenting. Methods: 85 consecutive cases of renal artery stenosis received renal angioplasty were retrospectively analyzed. 25 patients with related history were selected into diabetic group (DM), and 60 patients without diabetics into control group(NDM). Pre- and post- procedure serum creatinine and blood pressure between the 2 groups were collected and analyzed. Results: The average serum creatinine pre-intervention and post-intervention were(132.24 ± 33.71) μmol/L, (126.32 ± 29.65) μmol/L for DM group, and(125.02 ± 48.13) μmol/L, (118.31 ± 39.58) μmol/L for NDM group respectively with no significant statistical difference (P > 0.05). The blood pressure was controlled satisfactorily for both groups after the procedure, with statistical significance (P<0.05), but no difference between the two groups. Conclusions: The procedure with renal artery stenting is effective to maintain renal function and control hypertension, showing equal efficiency for both DM and NDM patients. (authors)

  4. Heparin-bonded, expanded polytetrafluoroethylene-lined stent graft in the treatment of femoropopliteal artery disease: 1-year results of the VIPER (Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease) trial.

    Science.gov (United States)

    Saxon, Richard R; Chervu, Arun; Jones, Paul A; Bajwa, Tanvir K; Gable, Dennis R; Soukas, Peter A; Begg, Richard J; Adams, John G; Ansel, Gary M; Schneider, Darren B; Eichler, Charles M; Rush, Michael J

    2013-02-01

    To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency. In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%. The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  5. The SPIRIT V study: a clinical evaluation of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with de novo coronary artery lesions.

    Science.gov (United States)

    Grube, Eberhard; Chevalier, Bernard; Smits, Peter; Džavík, Vladimir; Patel, Tejas M; Mullasari, Ajit S; Wöhrle, Jochen; Stuteville, Marrianne; Dorange, Cécile; Kaul, Upendra

    2011-02-01

    The SPIRIT V (A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions) study is a post-market surveillance experience of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) in patients with higher-risk coronary anatomy. Previous pre-approval studies have shown the safety and efficacy of EES in highly selected groups of patients. The SPIRIT V trial is a prospective, open label, single arm, multicenter study. Two thousand seven hundred patients with multiple de novo coronary artery lesions suitable for treatment with a planned maximum of 4 EES were enrolled at 93 centers in Europe, Asia Pacific, Canada, and South Africa. Lesions had a reference vessel diameter between 2.25 and 4.0 mm and a length of ≤ 28 mm by visual estimation. An independent clinical events committee adjudicated all end point-related events. The primary end point was the composite rate of all death, myocardial infarction (MI), and target vessel revascularization at 30 days. Secondary end points included stent thrombosis and acute success (clinical device and procedure success). At 30 days, the primary composite end point of all death, MI, and target vessel revascularization was 2.7%. At 1 year, rates of cardiac death, overall MI, and target lesion revascularization were 1.1%, 3.5%, and 1.8%, respectively. The cumulative rate of definite and probable stent thrombosis was low at 0.66% at 1 year. Use of EES in patients with multiple, complex de novo lesions yielded 1-year major adverse cardiac events, stent thrombosis, and target lesion revascularization rates that are comparable to those of the more controlled SPIRIT II and SPIRIT III trials-which included patients with restricted inclusion/exclusion criteria-and other all-comer population, physician-initiated studies like the X-SEARCH (Xience Stent Evaluated At Rotterdam Cardiology Hospital) and COMPARE (A Randomized

  6. Endovascular treatment with angioplasty or stenting versus endarterectomy in patients with carotid artery stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2009-10-01

    Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS).

  7. Preliminary clinical application in the cranial internal carotid artery of covered stents specially designed for intracranial vasculature

    International Nuclear Information System (INIS)

    Li Minghua; Luo Qiyi; Fang Chun; Xie Zhiyong; Cheng Yingsheng; Gao Bulang; Li Yu; Zhang Beilei; Xie Jian; Wang Yongli

    2007-01-01

    Objective: To investigate the flexibility of both the covered stents specially designed for use in intracranial vasculature and the delivering system in passing through the bone tube and the physiological curves of the cranial internal carotid artery (CICA) to reach the targeted area, the performance (adherence) of the covered stents in occluding vascular wall diseases and the impact on the vascular branches of the covered segment. Methods: The covered stents specially designed for use in intracranial vasculature were used to treat 13 patients with CICA diseases using endovascular techniques. There were 4 huge pseudoaneurysms, 4 giant aneurysms, 3 small wide-necked aneurysms, 1 giant pseudoaneurysm with concurrent internal carotid cavernous fistula (CCF), and 1 CCF. Prior to the detachment of the covered stents, balloon occlusion test (BOT) of the internal carotid artery on the diseased side and whole-brain digital subtraction angiography (DSA) were performed in all the patients. Three to 16 months following procedure, DSA and clinical follow-ups were performed. Results: Thirteen patients all tolerated the BOT well with the DSA demonstrating well-opened anterior and posterior communicating arteries. The covered stents and the delivering systems all successfully passed CICA to reach the targeted diseased area, with the diseased segments of the internal carotid artery including C3-C4 in 4 cases, C4-C5 in 4 and C6-C7 in 5. Immediately following the detachment of the covered stents, DSA demonstrated that 7 aneurysms were completely occluded, 4 aneurysms had slight endoleak, and 1 CCF had markedly-decreased blood flow through the fistula. In the patient with concurrent pseudoaneurysm and CCF, the pseudoaneurysm disappeared and the blood flow through the fistula was markedly-reduced immediately following the stenting procedure. Apart from one patient with aneurysmal subarachnoid hemorrhage who died due to extensive vascular spasm on the 9th day following the stenting

  8. Clinical benefits of drug-eluting stent implantation in septuagenarians with coronary artery disease

    International Nuclear Information System (INIS)

    Fang Yuehua; Shen Weifeng; Zhang Ruiyan; Zhang Jiansheng; Hu Jian; Zhang Xian; Zheng Aifang

    2005-01-01

    Objective: This study evaluated the safety and long-term outcomes of drug-eluting stents in septuagenarians with coronary artery disease. Methods: Two hundred and thirty-nine consecutive patients with coronary artery disease underwent drug-eluting stenting, including 88 patients aged ≥70 years (group A) and 151 aged <70 years (group B). Baseline clinical characteristics, procedural success rate, occurrence of cardiac events during follow-up were recorded and compared between the two groups. Results: Procedural success rate and complications were similar for the two groups. During follow-up, group A had higher recurrence rate of chest pain than group B (23.9% vs. 7.3%, P<0.001), and occurrence of cardiac events was higher in group A than in group B (5.7% vs. 2.7%, P<0.296). There was no significant difference in the frequency of restenosis between the two groups. Conclusions: Drug-eluting stent implantation for septuagenarians with coronary artery disease is safe but may have more recurrence of angina than younger ones during long-term follow-up. (authors)

  9. Spontaneous coronary artery dissection: complete angiographic resolution without stenting

    Directory of Open Access Journals (Sweden)

    Alexandre Abizaid

    2007-09-01

    Full Text Available A case of spontaneous coronary artery dissection in a 49-year-oldwoman is presented. She did not present the classical cardiovascular riskfactors. Etiology and treatment are discussed. She underwent primarypercutaneous coronary intervention of the left anterior descendingartery with no stenting and had complete angiographic resolution.

  10. Evaluation of XIENCE V everolimus-eluting and Taxus Express2 paclitaxel-eluting coronary stents in patients with jailed side branches from the SPIRIT IV trial at 2 years.

    Science.gov (United States)

    Forrest, John K; Lansky, Alexandra J; Meller, Stephanie M; Hou, Liming; Sood, Poornima; Applegate, Robert J; Wang, John C; Skelding, Kimberly A; Shah, Aakar; Kereiakes, Dean J; Sudhir, Krishnankutty; Cristea, Ecaterina; Yaqub, Manejeh; Stone, Gregg W

    2013-06-01

    The aim of this study was to determine whether patients from the Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions (SPIRIT) IV trial who underwent percutaneous coronary intervention, who had target lesions with jailed side branches, had improved clinical outcomes when treated with the XIENCE V versus Taxus Express(2) drug-eluting stent. In the SPIRIT III randomized trial, patients with target lesions with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had lower 2-year rates of major adverse cardiac events. The SPIRIT IV trial represents a larger more diverse patient population compared with SPIRIT III. In the large-scale, prospective, multicenter, randomized SPIRIT IV trial, 3,687 patients who underwent coronary stenting with up to 3 de novo native coronary artery lesions were randomized 2:1 to receive XIENCE V versus Taxus Express(2) stents. Two-year clinical outcomes of patients with or without jailed side branches after stenting were compared. A jailed side branch was defined as any side branch >1.0 mm in diameter within the target segment being stented, excluding bifurcations deemed to require treatment. Of the 3,687 patients in SPIRIT IV, a total of 1,426 had side branches that were jailed during angioplasty of the target lesion. Patients with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had significantly lower 2-year rates of target lesion failure (6.5% vs 11.9%, p = 0.001), major adverse cardiac events (6.6% vs 12.2%, p = 0.0008), ischemia-driven target vessel revascularization (4.1% vs 7.9%, p = 0.004), and stent thrombosis (0.6% vs 2.8%, p = 0.001). In conclusion, patients with jailed side branches after stenting with XIENCE V compared to Taxus Express(2) devices had superior clinical outcomes at 2 years in the large-scale randomized SPIRIT IV trial. Copyright © 2013 Elsevier Inc. All

  11. Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); M-C. Morice (Marie-Claude); A.P. Kappetein (Arie Pieter); A. Colombo (Antonio); D.R. Holmes Jr (David); M.J. Mack (Michael); E. Stahle (Elisabeth); T.E. Feldman (Ted); M.J.B.M. van den Brand (Marcel); E.J. Bass (Eric); N. van Dyck (Nic); K. Leadly (Katrin); K.D. Dawkins (Keith); F.W. Mohr (Friedrich)

    2009-01-01

    textabstractBACKGROUND Percutaneous coronary intervention (PCI) involving drug-eluting stents is increasingly used to treat complex coronary artery disease, although coronary-artery bypass grafting (CABG) has been the treatment of choice historically. Our trial compared PCI and CABG for treating

  12. Carotid Artery Stenting in a Patient with Spontaneous Recanalization of a Proximal Internal Carotid Artery Occlusion: a Case Report

    International Nuclear Information System (INIS)

    Kim, Eui Jong; Koh, Jun Seok; Choi, Woo Suk

    2006-01-01

    We report here on a rare case of carotid artery angioplasty and stenting in a patient with spontaneous recanalization after complete occlusion of the proximal internal carotid artery (ICA). The patient initially showed severe stenosis at the left proximal ICA on MR angiography (MRA). Digital subtraction angiography (DSA) performed three days after MRA showed complete occlusion of the proximal ICA. The follow-up DSA after four weeks showed recanalization of the ICA, and then carotid artery stenting was successfully performed. There has been no neurologic complication during more than one year follow-up. cute internal carotid artery (ICA) occlusions may result in profound disability and death (1). An occluded ICA can spontaneously recanalize, but this doesn't happen frequently, and the natural course of a proximal ICA occlusion and its possibility of recanalization, including the exact time of recanalization after occlusion, are not well known (2, 3). A few studies have reported the incidence of spontaneous recanalization of the proximal internal carotid artery, which has mostly occurred in patients with ICA dissections (4 6). A few limited studies have reported a considerable incidence of spontaneous recanalization in patients with underlying atherosclerotic lesion or atherothombotic diseases (2). The possibility of repeated occlusion and repeated cerebral ischemic infarction may exist for the patients exhibiting spontaneous recanalization of the ICA and underlying atherosclerosis. We report here on a case of carotid artery stenting (CAS) in a patient who exhibited underlying atherosclerosis with spontaneous recanalization after complete occlusion of the proximal ICA

  13. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).

    Science.gov (United States)

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin

    2017-06-26

    This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  14. Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito [Kainan Hospital Aichi Prefectural Welfare Federation of Agricultural Cooperatives, Department of Neurosurgery, Aichi (Japan); Miyachi, Shigeru; Hattori, Kenichi [Nagoya University Graduate School of Medicine, Department of Neurosurgery, Nagoya (Japan)

    2006-11-15

    Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)

  15. Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note

    International Nuclear Information System (INIS)

    Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito; Miyachi, Shigeru; Hattori, Kenichi

    2006-01-01

    Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)

  16. Pulmonary arterial stent implantation in an adult with Williams syndrome

    NARCIS (Netherlands)

    Reesink, Herre J.; Henneman, Onno D. F.; van Delden, Otto M.; Biervliet, Jules D.; Kloek, Jaap J.; Reekers, Jim A.; Bresser, Paul

    2007-01-01

    We report a 38-year-old patient who presented with pulmonary hypertension and right ventricular dysfunction due to pulmonary artery stenoses as a manifestation of Williams syndrome, mimicking chronic thromboembolic pulmonary hypertension. The patient was treated with balloon angioplasty and stent

  17. Angiographic follow-up after carotid artery stenting of bifurcation stenosis; Angiographische Verlaufskontrolle nach Stentimplantation zur Behandlung der Karotisbifurkationsstenose

    Energy Technology Data Exchange (ETDEWEB)

    Hauth, E.A.; Forsting, M. [Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitaetsklinik Essen (Germany); Jansen, C.; Drescher, R.; Mathias, K. [Radiologische Klinik, Klinikum Dortmund (Germany); Schwarz, M. [Neurologische Klinik, Klinikum Dortmund (Germany); Christmann, A. [Fachbereich Statistik, Univ. Dortmund (Germany); Jaeger, H. [Radiologische Klinik, Klinikum Dortmund (Germany); Marien-Hospital Wesel, Praxis fuer Radiologie, Neuroradiologie and Nuklearmedizin (Germany)

    2006-08-15

    Purpose: the purpose of this prospective study was to determine the restenosis grade, the intima hyperplasia and the stent expansion via angiographic follow-up six months after carotid artery stenting. Materials and methods: in 100 patients, angiographic follow-up was performed 5.9 months (range: 2.9 - 11.4 months) after carotid artery stenting. The restenosis grade, the intima hyperplasia and the stent expansion were measured by selective angiography of the treated carotid artery. Results: the mean restenosis grade was 16% (range: 0 - 78%). In 6 of 100 patients (6%), a restenosis grade of > 50% was measured. In 4 patients the restenosis grade was 50 - 70%. In 2 patients the restenosis grade was > 70%. In 91 of 100 patients (91%), the restenosis was localized in the former area of stenosis of the carotid artery, and in 9 of 100 patients (9%), the restenosis was localized in the cranial stent end. The mean grade of intima hyperplasia was 31% (range: 2 - 70%). The mean increase in stent expansion at the time of follow-up was 10% (range: 0 - 59%). No correlation was able to be determined between the grade of stenosis and the grade of restenosis (rho = 0,017, range: -0.180 - 0.213), between the grade of residual stenosis and the grade of restenosis (rho = 0,257, range: 0.064 - 0.431) and between intima hyperplasia and the grade of restenosis (rho = 0,476, range: 0.309 - 0.615). Conclusions: carotid artery stenting is associated with a low incidence of high-grade restenosis 6 months after an intervention. The intima hyperplasia, which can be observed in each Wallstent, is partly compensated by the expansion of the self-expandable stent. Without a correlation between the grade of residual stenosis and the grade of restenosis, low-grade residual stenosis can be accepted. Therefore, we recommend undersized postdilation of the Wallstent. (orig.)

  18. High-definition computed tomography for coronary artery stents imaging: Initial evaluation of the optimal reconstruction algorithm.

    Science.gov (United States)

    Cui, Xiaoming; Li, Tao; Li, Xin; Zhou, Weihua

    2015-05-01

    The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0±8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Peri-stent aneurysm formation following a stent implant for stenotic intracranial vertebral artery dissection: a technical report of two cases successfully treated with coil embolization.

    Science.gov (United States)

    Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro

    2013-02-01

    Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.

  20. New stent design for use in small coronary arteries during percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Juan F Granada

    2010-10-01

    Full Text Available Juan F Granada1, Barbara A Huibregtse2, Keith D Dawkins21The Jack H Skirball Center for Cardiovascular Research, Cardiovascular Research Foundation, Columbia University Medical Center, New York, NY, USA; 2Boston Scientific Corporation, Natick, MA, USAAbstract: Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel, and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches, intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001, instent binary restenosis (13.0% versus 38.1%, P < 0.001, and target lesion revascularization (5.8% versus 17.6%, P < 0.001 at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03 and instent binary restenosis (13.0% versus 25.9%, P = 0.02 when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS

  1. In vitro stent lumen visualisation of various common and newly developed femoral artery stents using MR angiography at 1.5 and 3 tesla.

    Science.gov (United States)

    Syha, R; Ketelsen, D; Kaempf, M; Mangold, S; Sixt, S; Zeller, T; Springer, F; Schick, F; Claussen, C D; Brechtel, K

    2013-02-01

    To evaluate stent lumen assessment of various commonly used and newly developed stents for the superficial femoral artery (SFA) using MR angiography (MRA) at 1.5 and 3 T. Eleven nitinol stents and one cobalt-chromium stent were compared regarding stent lumen visualisation using a common three-dimensional MRA sequence. Maximum visible stent lumen width and contrast ratio were analysed in three representative slices for each stent type. A scoring system for lumen visualisation was applied. Nitinol stents showed significantly better performance than the cobalt chromium stent (P stent lumen ranged between 43.4 and 95.5 %, contrast ratio between 7.2 and 110.6 %. Regarding both field strengths, seven of the nitinol stents were classified as "suitable". Three nitinol stents were "limited", and one nitinol stent and the cobalt chromium stent were "not suitable". Intraluminal loss of signal and artefacts of most of the SFA stents do not markedly limit assessment of stent lumen by MRA at 1.5 and 3 T. MRA can thus be considered a valid technique for detection of relevant in-stent restenosis. Applied field strength does not strongly influence stent lumen assessment in general, but proper choice of field strength might be helpful.

  2. Symptomatic intracranial vertebral artery atherosclerotic stenosis (≥70%) with concurrent contralateral vertebral atherosclerotic diseases in 88 patients treated with the intracranial stenting

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zi-Liang [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China); Gao, Bu-Lang [Department of Medical Research Shijiazhuang First Hospital, Hebei Medical University (China); Li, Tian-Xiao, E-mail: litianxiaod@163.com [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China); Cai, Dong-Yang; Zhu, Liang-Fu; Bai, Wei-Xing; Xue, Jiang-Yu; Li, Zhao-Shuo [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China)

    2015-09-15

    Highlights: • Symptomatic vertebral artery stenosis can be treated with intracranial stenting. • Stenting for intracranial vertebral artery stenosis is safe and effective. • Stenting for intracranial vertebral artery stenosis can prevent long-term stroke. - Abstract: Purpose: To investigate the safety, effect and instent restenosis rate of Wingspan stenting in treating patients with intracranial vertebral artery atherosclerotic stenosis (70–99%) concurrent with contralateral vertebral artery atherosclerotic diseases. Materials and methods: Eighty-eight patients with severe symptomatic intracranial vertebral artery atherosclerotic stenosis (≥70%) combined with contralateral vertebral artery atherosclerotic diseases were treated with the Wingpsan stent. All the baseline, cerebral angiography, success rate, perioperative complications, clinical and imaging follow-up data were prospectively analyzed. Results: The success rate of stenting was 100%, and the mean stenotic rate was reduced from prestenting (84.9 ± 6.8)% to poststenting (17.2 ± 5.9)%. The perioperative stroke rate was 1.1%. Among eighty patients (90.9%) with clinical follow-up 8-62 months (mean 29.3 ± 17.2) poststenting, five (6.3%) had posterior circulation TIA only, three (3.8%) had mild stroke in the posterior circulation but recovered completely, and another five patients greater than 70 years old died of non-ischemic stroke. Imaging follow-up in 46 patients (52.3%) 5–54 months (mean 9.9 ± 9.9) following stenting revealed instent restenosis in 12 patients (26.1%) including 7 (58.3%) symptomatic restenosis. Age and residual stenosis were the two factors to significantly (P < 0.05) affect instent restenosis. Conclusion: Wingspan stenting in the intracranial vertebral artery atherosclerotic stenosis combined with contralateral vertebral artery atherosclerotic diseases has a low perioperative stroke rate and a good preventive effect on long-term ischemic stroke, but the instent restenosis

  3. High-definition computed tomography for coronary artery stents imaging: Initial evaluation of the optimal reconstruction algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Xiaoming, E-mail: mmayzy2008@126.com; Li, Tao, E-mail: litaofeivip@163.com; Li, Xin, E-mail: lx0803@sina.com.cn; Zhou, Weihua, E-mail: wangxue0606@gmail.com

    2015-05-15

    Highlights: • High-resolution scan mode is appropriate for imaging coronary stent. • HD-detail reconstruction algorithm is stent-dedicated kernel. • The intrastent lumen visibility also depends on stent diameter and material. - Abstract: Objective: The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Materials and methods: Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. Results: The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0 ± 8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Conclusions: Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement.

  4. FiberNet--a new embolic protection device for carotid artery stenting.

    Science.gov (United States)

    Bauer, C; Franke, J; Bertog, S C; Woerner, V; Ghasemzadeh-Asl, S; Sievert, H

    2014-05-01

    Though distal filter protection during carotid stenting reduces the risk of cerebrovascular events, periprocedural stroke remains a risk despite their broad usage. This observation may be related to the pore size of common filters. The FiberNet distal filter system is unique by its very small pore size (40 µm) as well as its low profile and flexibility. Little data is available regarding the clinical performance and safety of this device. The aim was the evaluation of the safety of the FiberNet embolic protection system during carotid artery stenting. All consecutive patients treated with carotid stenting at our institution using the FiberNet device were systematically followed. Primary endpoint was the rate of all death and stroke within 30 days of the procedure. Carotid artery stenting using the FiberNet embolic protection system was performed in 54 patients. The procedure was technical successful in all patients. Three patients (5.5%) had a TIA. Amauosis fugax occurred in two patients (3.7%). One patient (1.9%) had a minor stroke with hemiparesis of the left arm and face which resolved completely within 48 hr after the procedure. No patient died or suffered a major stroke. The safety and feasibility of the FiberNet distal protection system appears to be at least equivalent to that reported in studies using conventional distal filter protection. Copyright © 2013 Wiley Periodicals, Inc.

  5. Balloon-Expandable Stent Graft for Treating Uretero-Iliac Artery Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Guntau, Moritz, E-mail: guntau@med.uni-marburg.de [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hegele, Axel [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Rheinheimer, Stephan [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hofmann, Rainer [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Mahnken, Andreas H. [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany)

    2017-06-15

    PurposeTo evaluate the safety, efficacy and outcome of percutaneous balloon-expandable covered stent graft placement for uretero-iliac artery fistula (UAF) treatment.MethodsThis retrospective study evaluated the single-center experience of percutaneous balloon-expandable covered stent graft placement (ADVANTA™, Atrium Hudson, NH, USA) in UAF. Data were obtained from a prospective institutional database. Patient follow-up included complications, symptoms recurrence and mortality rate.ResultsTen UAFs in eight patients (3 males; 5 females) with a mean age of 64.5 (35–77) years were identified. All patients had a history pelvic malignancy, extirpative surgery (n = 6), long-term ureteral stenting (n = 7) and pelvic radiation (n = 5). All procedures were completed successfully without complications. Thirty-day mortality rate was zero. At a median follow-up of 6 (1–60) months, one patient suffered recurrent hematuria requiring a secondary stent graft placement 26 months after the initial treatment. During follow-up, five patients died of the underlying disease (43, 66, 105, and 183 and 274 days after the last procedure).ConclusionPercutaneous balloon-expandable stent graft placement in UAF is a safe and effective treatment option. Implantation of stent grafts should be considered as treatment of choice in UAF.

  6. A novel application of the culotte stent technique to bail out a jailed common iliac artery

    Directory of Open Access Journals (Sweden)

    Hideto Sangen, MD

    2017-12-01

    Full Text Available Implanting a self-expandable stent at the ostium of the common iliac artery (CIA may lead to coverage of the orifice of the contralateral CIA. Here, we describe a novel application of the culotte stent technique using a balloon-expandable stent to bail out an ostial stenotic legion of a jailed CIA due to prior self-expandable stent placement. The bilateral CIAs were revascularized by culotte stenting, and patency of the stents was confirmed 3 years after the procedure. The culotte stent technique was successfully applied to an ostial stenotic lesion of a jailed CIA.

  7. Life-threatening bleeding from a vertebral artery pseudoaneurysm after anterior cervical spine approach: endovascular repair by a triple stent-in-stent method. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Alzamora, M.G.; Klisch, J. [Section of Neuroradiology, Neurocenter, University of Freiburg (Germany); Rosahl, S.K.; Lehmberg, J. [Department of Neurosurgery, Neurocenter, University of Freiburg (Germany)

    2005-04-01

    The incidence of injury to the cervical vertebral artery during surgery for stenosis of the cervical neuroforamina is very low. We present a case in which bleeding during microforaminotomy at the level C6/7 occurred. The bleeding could be controlled intraoperatively. Two days later, a life-threatening cervical hematoma required urgent bedside evacuation. A false aneurysm of the left cervical vertebral artery was successfully occluded by a modified triple stent-in-stent technique, maintaining the flow in the vessel.

  8. Life-threatening bleeding from a vertebral artery pseudoaneurysm after anterior cervical spine approach: endovascular repair by a triple stent-in-stent method. Case report

    International Nuclear Information System (INIS)

    Alzamora, M.G.; Klisch, J.; Rosahl, S.K.; Lehmberg, J.

    2005-01-01

    The incidence of injury to the cervical vertebral artery during surgery for stenosis of the cervical neuroforamina is very low. We present a case in which bleeding during microforaminotomy at the level C6/7 occurred. The bleeding could be controlled intraoperatively. Two days later, a life-threatening cervical hematoma required urgent bedside evacuation. A false aneurysm of the left cervical vertebral artery was successfully occluded by a modified triple stent-in-stent technique, maintaining the flow in the vessel

  9. Endovascular repair of renal artery aneurysm with the multilayer stent – a short report

    Directory of Open Access Journals (Sweden)

    Vojko Flis

    2012-10-01

    in the main left renal artery involving all three major branches of the renal artery. Via a percutaneous femoral approach a multilayer stent was deployed without complications. Blood flow inside the sac was immediately and significantly reduced. All the renal branches remained patent. Conclusion: New multilayer fluid modulating stent concept appears to be a very useful and attractive alternative to surgery or other endovascular techniques for those RAA involving or very close to major branch vessels, especially in patients with very high risk of loosing the only viable kidney, as in our case.

  10. Endovascular treatment of penetrating arterial trauma with stent grafts.

    Science.gov (United States)

    Biagioni, Rodrigo Bruno; Burihan, Marcelo Calil; Nasser, Felipe; Biagioni, Luisa Ciucci; Ingrund, José Carlos

    2018-02-01

    The endovascular management of arterial injuries has resulted in reduced operating time, blood loss, hospital mortality, lower incidence of sepsis, and decrease in mortality rates. For penetrating trauma, however, the benefits of endovascular therapy are questionable. Data were obtained by retrospective analysis of electronic medical records. All patients with vascular trauma seeking care at our institution from January 2010 to December 2015 were reviewed. A total of 223 vascular trauma patients were enrolled. Of these, 18 patients (8 %) were treated with endovascular techniques. The data related to clinical presentation, patient characteristics, technical aspects of the treatment, and follow-up were analysed. The mean patient age was 35.4 ± 17.8 years, 94 % were male. The mean injury severity score was 10.4 ± 2.5. The most commonly observed trauma mechanism was a gunshot in 10 cases (55 %), followed by lesions provoked by arterial catheter misplacement in five cases (27 %), and stab wounds in three cases (16.6 %). The main injury site was the subclavian artery, accounting for eight cases (44 %), followed by the superficial femoral artery and the tibiofibular trunk in two cases, respectively (18 %). The anterior tibial, fibular artery, axillary, common carotid, superior mesenteric, and profunda femoris were each affected once. Arteriovenous fistula was detected in nine cases (50 %), pseudoaneurysms in nine cases (50 %), and short occlusion in two cases (11 %). The mean follow-up duration was 753 days. The primary patency rate was 92.3 and 61.5 % after one and two years, respectively. The survival rate was 94.4 % after one and two years. Infection of the stents or limb amputations were not identified at follow-up. The endovascular treatment of penetrating arterial injuries with covered stents is feasible. However, the criteria used to choose the best method must be individualized.

  11. Zotarolimus-eluting Resolute Integrity versus everolimus-eluting Xience Xpedition stents in the management of very long (>30 mm) de novo coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Patra, Soumya, E-mail: dr_soumyapatra@rediffmail.com; Chakraborty, Rabindra Nath; Pande, Arindam; Banerjee, Suvro; Jena, Manabhanjan; Mandal, Prakash Chandra; De, Swapan Kumar; Khan, Aftab; Das, Sankha Suvro; Ghosh, Debashish; Nag, Raja

    2017-04-15

    mm was used. These stents are used most frequently in our country. • Likewise previous study, we did not find any significant difference in the clinical outcome at 12 months. • Male-dominated patient population was also in similar kind from previous trial though the percentage was more than that of previous study. • Our study patients have less complex coronary artery disease than those from previous trials.

  12. Long-term outcomes after stenting versus endarterectomy for treatment of symptomatic carotid stenosis: the International Carotid Stenting Study (ICSS) randomised trial

    NARCIS (Netherlands)

    Bonati, Leo H.; Dobson, Joanna; Featherstone, Roland L.; Ederle, Jörg; van der Worp, H. Bart; de Borst, Gert J.; Mali, Willem P. Th M.; Beard, Jonathan D.; Cleveland, Trevor; Engelter, Stefan T.; Lyrer, Philippe A.; Ford, Gary A.; Dorman, Paul J.; Brown, Martin M.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Hacke, W.; Halliday, A.; Malik, I.; Mas, J. L.; McGuire, A. J.; Sidhu, P.; Venables, G.; Clifton, A.; Gaines, P.; Collins, R.; Molyneux, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Coward, L.; Dobson, J.; Doig, D.; Ederle, J.; Featherstone, R. F.; Kennedy, F.; Tindall, H.; Turner, E.; McCabe, D. J. H.; Wallis, A.; Brooks, M.; Chambers, B.; Koelemay, M. J. W.; Nederkoorn, P. J.; Reekers, J. A. A.; Roos, Y. B. W. E. M.

    2015-01-01

    Background Stenting is an alternative to endarterectomy for treatment of carotid artery stenosis, but long-term efficacy is uncertain. We report long-term data from the randomised International Carotid Stenting Study comparison of these treatments. Methods Patients with symptomatic carotid stenosis

  13. Long-term outcomes after stenting versus endarterectomy for treatment of symptomatic carotid stenosis: the International Carotid Stenting Study (ICSS) randomised trial

    NARCIS (Netherlands)

    Bonati, L.H.; Dobson, J.; Featherstone, R.L.; Ederle, J.; Worp, H.B. van der; Borst, G.J. de; Mali, W.P.; Beard, J.D.; Cleveland, T.; Engelter, S.T.; Lyrer, P.A.; Ford, G.A.; Dorman, P.J.; Brown, M.M.; Leeuw, F.E. de; et al.,

    2015-01-01

    BACKGROUND: Stenting is an alternative to endarterectomy for treatment of carotid artery stenosis, but long-term efficacy is uncertain. We report long-term data from the randomised International Carotid Stenting Study comparison of these treatments. METHODS: Patients with symptomatic carotid

  14. Mechanical behavior of peripheral stents and stent-vessel interaction: A computational study

    Science.gov (United States)

    Dottori, Serena; Flamini, Vittoria; Vairo, Giuseppe

    2016-05-01

    In this paper stents employed to treat peripheral artery disease are analyzed through a three-dimensional finite-element approach, based on a large-strain and large-displacement formulation. Aiming to evaluate the influence of some stent design parameters on stent mechanics and on the biomechanical interaction between stent and arterial wall, quasi-static and dynamic numerical analyses are carried out by referring to computational models of commercially and noncommercially available versions of both braided self-expandable stents and balloon-expandable stents. Addressing isolated device models, opening mechanisms and flexibility of both opened and closed stent configurations are numerically experienced. Moreover, stent deployment into a stenotic peripheral artery and possible postdilatation angioplasty (the latter for the self-expandable device only) are simulated by considering different idealized vessel geometries and accounting for the presence of a stenotic plaque. Proposed results highlight important differences in the mechanical response of the two types of stents, as well as a significant influence of the vessel shape on the stress distributions arising upon the artery-plaque system. Finally, computational results are used to assess both the stent mechanical performance and the effectiveness of the stenting treatment, allowing also to identify possible critical conditions affecting the risk of stent fracture, tissue damage, and/or pathological tissue response.

  15. Everolimus-eluting bioresorbable stent vs. durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Sabaté, Manel; Windecker, Stephan; Iñiguez, Andres

    2015-01-01

    AIMS: Patients with ST-segment elevation myocardial infarction (STEMI) feature thrombus-rich lesions with large necrotic core, which are usually associated with delayed arterial healing and impaired stent-related outcomes. The use of bioresorbable vascular scaffolds (Absorb) has the potential...... to overcome these limitations owing to restoration of native vessel lumen and physiology at long term. The purpose of this randomized trial was to compare the arterial healing response at short term, as a surrogate for safety and efficacy, between the Absorb and the metallic everolimus-eluting stent (EES...... was the 6-month optical frequency domain imaging healing score (HS) based on the presence of uncovered and/or malapposed stent struts and intraluminal filling defects. Main secondary endpoint included the device-oriented composite endpoint (DOCE) according to the Academic Research Consortium definition...

  16. Accidental Coverage of Both Renal Arteries during Infrarenal Aortic Stent-Graft Implantation: Cause and Treatment

    Directory of Open Access Journals (Sweden)

    Umberto Marcello Bracale

    2014-01-01

    Full Text Available The purpose of this paper is to report a salvage maneuver for accidental coverage of both renal arteries during endovascular aneurysm repair (EVAR of an infrarenal abdominal aortic aneurysm (AAA. A 72-year-old female with a 6 cm infrarenal abdominal aortic aneurysm was treated by endovascular means with a standard bifurcated graft. Upon completing an angiogram, both renal arteries were found to be accidentally occluded. Through a left percutaneous brachial approach, the right renal artery was catheterized and a chimney stent was deployed; however this was not possible for the left renal artery. A retroperitoneal surgical approach was therefore carried out with a retrograde chimney stent implanted to restore blood flow. After three months, both renal arteries were patent and renal function was not different from the baseline. Both endovascular with percutaneous access via the brachial artery and open retroperitoneal approaches with retrograde catheterization are feasible rescue techniques to recanalize the accidentally occluded renal arteries during EVAR.

  17. Covered stents for endovascular repair of iatrogenic injuries of iliac and femoral arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kufner, Sebastian, E-mail: kufners@dhm.mhn.de [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Cassese, Salvatore; Groha, Philipp; Byrne, Robert A. [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Schunkert, Heribert; Kastrati, Adnan [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Ott, Ilka; Fusaro, Massimiliano [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany)

    2015-04-15

    Background: The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. A strategy of percutaneous transluminal angioplasty (PTA) with covered stent (CS) may represent a valuable alternative to open surgery. However, systematic evaluations of CS in this setting represent a scientific gap. In the present study, we investigate the procedural and clinical outcomes associated with PTA and CS implantation to repair iatrogenic injuries of peripheral arteries. Methods: All patients undergoing PTA with CS for endovascular repair of iatrogenic injuries of peripheral arteries between August 2010 and July 2013 at our Institution were retrospectively analyzed. The primary endpoint was the technical success. Secondary endpoints were in-hospital mortality and cumulative death, target lesion revascularization (TLR), amputation and major stroke at 12-month follow-up. Results: During the period of observation, a total of 30 patients underwent PTA with either self-expandable (43.3%) or balloon-expandable CS (56.7%) for iatrogenic injuries of peripheral arteries. Injuries consisted of perforation/rupture (76.7%), arteriovenous fistula (16.7%) and pseudoaneurysm (6.7%) of iliac–femoral arteries. Technical success was achieved in all cases. Median follow-up was 409 days [210–907]. The incidence of in-hospital mortality was 10.0%. At 12-month follow-up, the incidence of death, TLR, amputation and major stroke was 20.0%, 17.0%, 3.3% and 6.7%, respectively. Conclusion: The use of covered stents for endovascular repair of iatrogenic injuries of peripheral arteries shows a high technical success and may be alternative to surgery. Further studies with larger populations are needed to confirm these preliminary findings. - Highlights: • The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. • Percutaneous transluminal angioplasty with

  18. Coronary artery bypass surgery or coronary stenting in diabetic patients: too soon to make a statement?

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Alfredo E., E-mail: arodriguez@centroceci.com.ar

    2014-11-15

    Diabetic patients have been associated with poor procedural and long term outcome if they were treated either with percutaneous coronary interventions or coronary artery bypass surgery. Recently several randomized clinical trials (RCT) in this subset of patients have been published showing a greater incidence of major adverse cardiovascular events, death/myocardial infarction/stroke, if they were treated with first generation drug eluting stents (DES) which was not observed previously in the bare metal stent era. However, almost simultaneously with this data, several RCT demonstrated better safety profile with new generation DES including biocompatible polymers, biodegradable polymers and lately complete absorbable DES, all of them showed reduction in adverse cardiac events compared to 1st generation DES in patients with diabetes. In this editorial we review the old and new randomized data in diabetic patients and conclude that there are many unresolved issues to make a definitive statement regarding which is the best revascularization preference in diabetic patients and the measured final efficacy of PCI and CABG will not be reached until the arrival of RCT using next generation DES, including complete absorbable scaffolds. - Highlights: • Diabetic patients have been associated with poor procedural and long term outcome if they were treated either with percutaneous coronary interventions or coronary artery bypass surgery. Recently several randomized clinical trials (RCT) in this subset of patients have been published showing a greater incidence of major adverse cardiovascular events, death/myocardial infarction/stroke, if they were treated with first generation drug eluting stents (DES) which was not observed previously in the bare metal stent era. • In recent years, several RCT demonstrated better safety profile with new generation DES including biocompatible polymers, biodegradable polymers and lately complete absorbable DES, all of them showed reduction in

  19. Coronary artery bypass surgery or coronary stenting in diabetic patients: too soon to make a statement?

    International Nuclear Information System (INIS)

    Rodriguez, Alfredo E.

    2014-01-01

    Diabetic patients have been associated with poor procedural and long term outcome if they were treated either with percutaneous coronary interventions or coronary artery bypass surgery. Recently several randomized clinical trials (RCT) in this subset of patients have been published showing a greater incidence of major adverse cardiovascular events, death/myocardial infarction/stroke, if they were treated with first generation drug eluting stents (DES) which was not observed previously in the bare metal stent era. However, almost simultaneously with this data, several RCT demonstrated better safety profile with new generation DES including biocompatible polymers, biodegradable polymers and lately complete absorbable DES, all of them showed reduction in adverse cardiac events compared to 1st generation DES in patients with diabetes. In this editorial we review the old and new randomized data in diabetic patients and conclude that there are many unresolved issues to make a definitive statement regarding which is the best revascularization preference in diabetic patients and the measured final efficacy of PCI and CABG will not be reached until the arrival of RCT using next generation DES, including complete absorbable scaffolds. - Highlights: • Diabetic patients have been associated with poor procedural and long term outcome if they were treated either with percutaneous coronary interventions or coronary artery bypass surgery. Recently several randomized clinical trials (RCT) in this subset of patients have been published showing a greater incidence of major adverse cardiovascular events, death/myocardial infarction/stroke, if they were treated with first generation drug eluting stents (DES) which was not observed previously in the bare metal stent era. • In recent years, several RCT demonstrated better safety profile with new generation DES including biocompatible polymers, biodegradable polymers and lately complete absorbable DES, all of them showed reduction in

  20. Bioabsorbable polymer-coated sirolimus-eluting stent implantation preserves coronary vasomotion: A DESSOLVE II trial sub-study.

    Science.gov (United States)

    Rusinaru, Dan; Vrolix, Mathias; Verheye, Stefan; Chowdhary, Saqib; Schoors, Danny; Di Mario, Carlo; Desmet, Walter; Donohoe, Dennis J; Ormiston, John A; Knape, Charlene; Bezerra, Hiram; Lansky, Alexandra; Wijns, William

    2015-12-01

    We studied coronary vasomotion in patients treated with the Mistent(®) absorbable polymer sirolimus-eluting stent (APSES) and in patients implanted with the Endeavor(®) zotarolimus-eluting stent (ZES). First generation (1st-gen) drug-eluting stents (DES) induce persistent vasomotor dysfunction in the treated coronary artery. It is unknown whether and to what extent the implantation of an absorbable polymer DES impairs coronary vasomotion. This sub-study of the DESSOLVE II trial included 19 APSES Mistent(®) and 10 ZES Endeavor(®) patients. Incremental atrial pacing and quantitative coronary angiography were used to assess vasomotion proximal and distal to the stent and in a reference segment at 9 months after implantation. Percent changes in vessel diameter with pacing versus baseline were calculated and compared. Vasomotor response of the APSES group was also compared with changes observed in a historical group of 17 patients implanted with a 1st-gen sirolimus-eluting stent (SES). Normal vasomotion (vasodilatation) was preserved and of comparable magnitude in the APSES and in the ZES group both proximally (P = 0.34) and distally (P = 0.38) to the stent. This finding was not observed in the 1st-gen SES group showing marked pacing-induced vasoconstriction at both stent edges (P absorbable polymer sirolimus-eluting stent is associated with preserved coronary vasomotion, comparable to that observed after implantation of the Endeavor(®) ZES, and distinct from 1st-gen SES which induce coronary vasomotor dysfunction. © 2015 Wiley Periodicals, Inc.

  1. Long-term forecasting and comparison of mortality in the Evaluation of the Xience Everolimus Eluting Stent vs. Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) trial: prospective validation of the SYNTAX Score II.

    Science.gov (United States)

    Campos, Carlos M; van Klaveren, David; Farooq, Vasim; Simonton, Charles A; Kappetein, Arie-Pieter; Sabik, Joseph F; Steyerberg, Ewout W; Stone, Gregg W; Serruys, Patrick W

    2015-05-21

    To prospectively validate the SYNTAX Score II and forecast the outcomes of the randomized Evaluation of the Xience Everolimus-Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) Trial. Evaluation of the Xience Everolimus Eluting Stent vs. Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization is a prospective, randomized multicenter trial designed to establish the efficacy and safety of percutaneous coronary intervention (PCI) with the everolimus-eluting stent compared with coronary artery bypass graft (CABG) surgery in subjects with unprotected left-main coronary artery (ULMCA) disease and low-intermediate anatomical SYNTAX scores (EXCEL, the SYNTAX Score II was prospectively applied to predict 4-year mortality in the CABG and PCI arms. The 95% prediction intervals (PIs) for mortality were computed using simulation with bootstrap resampling (10 000 times). For the entire study cohort, the 4-year predicted mortalities were 8.5 and 10.5% in the PCI and CABG arms, respectively [odds ratios (OR) 0.79; 95% PI 0.43-1.50). In subjects with low (≤22) anatomical SYNTAX scores, the predicted OR was 0.69 (95% PI 0.34-1.45); in intermediate anatomical SYNTAX scores (23-32), the predicted OR was 0.93 (95% PI 0.53-1.62). Based on 4-year mortality predictions in EXCEL, clinical characteristics shifted long-term mortality predictions either in favour of PCI (older age, male gender and COPD) or CABG (younger age, lower creatinine clearance, female gender, reduced left ventricular ejection fraction). The SYNTAX Score II indicates at least an equipoise for long-term mortality between CABG and PCI in subjects with ULMCA disease up to an intermediate anatomical complexity. Both anatomical and clinical characteristics had a clear impact on long-term mortality predictions and decision making between CABG and PCI. Published on behalf of the European Society of Cardiology. All rights reserved. © The

  2. Dose-Dependent Effect of Statin Pretreatment on Preventing the Periprocedural Complications of Carotid Artery Stenting.

    Science.gov (United States)

    Hong, Jeong-Ho; Sohn, Sung-Il; Kwak, Jaehyuk; Yoo, Joonsang; Chang, Hyuk Won; Kwon, O-Ki; Jung, Cheolkyu; Chung, Inyoung; Bae, Hee-Joon; Lee, Ji Sung; Han, Moon-Ku

    2017-07-01

    We investigated whether statin pretreatment can dose dependently reduce periprocedural complications in patients undergoing carotid artery stenting because of symptomatic carotid artery stenosis. We enrolled a consecutive series of 397 symptomatic carotid artery stenosis (≥50% stenosis on conventional angiography) treated with carotid artery stenting at 2 tertiary university hospitals over a decade. Definition of periprocedural complications included any stroke, myocardial infarction, and death within 1 month after or during the procedure. Statin pretreatment was divided into 3 categories according to the atorvastatin equivalent dose: none (n=158; 39.8%), standard dose (statin use were 12.0%, 4.5%, and 1.2%. After adjustment, a change in the atorvastatin dose category was associated with reduction in the odds of periprocedural complications for each change in dose category (standard-dose statin: odds ratio, 0.24; 95% confidence interval, 0.07-0.81; high-dose statin: odds ratio, 0.11; 95% confidence interval, 0.01-0.96; P for trend=0.01). Administration of antiplatelet drugs was also an independent factor in periprocedural complications (OR, 0.18; 95% CI, 0.05-0.69). This study shows that statin pretreatment may reduce the incidence of periprocedural complications dose dependently in patients with symptomatic carotid artery stenting. © 2017 American Heart Association, Inc.

  3. Comparison of enterprise and neuroform stent-assisted coil embolization of distal internal carotid artery aneurysms: Midterm results from a single-center experience

    International Nuclear Information System (INIS)

    Choi, Won Jin; Baik, Seung Kug; Yeom, Jeong A; Kim, Young Soo; Lee, Sang Weon

    2014-01-01

    To compare the mid-term follow-up angiographic findings in distal internal carotid artery (ICA) aneurysms treated by stent-assisted coil embolization using the Enterprise or Neuroform stent. We included 68 patients with 70 aneurysms: 31 cases with Enterprise and 39 cases with Neuroform. Inclusion criteria were 1) location of the stent within the distal ICA, including the carotid siphon; 2) follow-up angiogram after > 6 months, and 3) single use of the stent for 1 parent artery. The patients' mean age was 54.9 years (16 male and 52 female). Mean follow-up duration was 9.1 months. At follow-up, there were intraluminal filling defects of the parent artery in 19.4% of the Enterprise group and no filling defect in the Neuroform group. There was no significant in-stent stenosis in either group. Straightening of the parent artery was seen in 35.5% of the Enterprise group and 20.5% of the Neuroform group. Two Enterprise cases showed delayed migration. The Enterprise showed statistically significant intraluminal filling defects of the parent artery compared with the Neuroform. The rates of significant in-stent stenosis and straightening of the parent artery were not significantly different between the Enterprise and the Neuroform groups.

  4. Revascularisation versus medical treatment in patients with stable coronary artery disease: network meta-analysis

    Science.gov (United States)

    Stortecky, Stefan; Stefanini, Giulio G; daCosta, Bruno R; Rutjes, Anne Wilhelmina; Di Nisio, Marcello; Siletta, Maria G; Maione, Ausilia; Alfonso, Fernando; Clemmensen, Peter M; Collet, Jean-Philippe; Cremer, Jochen; Falk, Volkmar; Filippatos, Gerasimos; Hamm, Christian; Head, Stuart; Kappetein, Arie Pieter; Kastrati, Adnan; Knuuti, Juhani; Landmesser, Ulf; Laufer, Günther; Neumann, Franz-Joseph; Richter, Dimitri; Schauerte, Patrick; Sousa Uva, Miguel; Taggart, David P; Torracca, Lucia; Valgimigli, Marco; Wijns, William; Witkowski, Adam; Kolh, Philippe; Juni, Peter

    2014-01-01

    Objective To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. Design Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials while maintaining randomisation. Eligibility criteria for selecting studies A strategy of initial medical treatment compared with revascularisation by coronary artery bypass grafting or Food and Drug Administration approved techniques for percutaneous revascularization: balloon angioplasty, bare metal stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. Data sources Medline and Embase from 1980 to 2013 for randomised trials comparing medical treatment with revascularisation. Main outcome measure All cause mortality. Results 100 trials in 93 553 patients with 262 090 patient years of follow-up were included. Coronary artery bypass grafting was associated with a survival benefit (rate ratio 0.80, 95% credibility interval 0.70 to 0.91) compared with medical treatment. New generation drug eluting stents (everolimus: 0.75, 0.59 to 0.96; zotarolimus (Resolute): 0.65, 0.42 to 1.00) but not balloon angioplasty (0.85, 0.68 to 1.04), bare metal stents (0.92, 0.79 to 1.05), or early generation drug eluting stents (paclitaxel: 0.92, 0.75 to 1.12; sirolimus: 0.91, 0.75 to 1.10; zotarolimus (Endeavor): 0.88, 0.69 to 1.10) were associated with improved survival compared with medical treatment. Coronary artery bypass grafting reduced the risk of myocardial infarction compared with medical treatment (0.79, 0.63 to 0.99), and everolimus eluting stents showed a trend towards a reduced risk of myocardial infarction (0.75, 0.55 to 1.01). The risk of subsequent revascularisation was noticeably

  5. Conformally integrated stent cell resonators for wireless monitoring of peripheral artery disease

    KAUST Repository

    Viswanath, Anupam

    2013-01-01

    This paper presents the design and in vitro evaluation of magnetoelastic sensors intended for wireless monitoring of tissue accumulation in peripheral artery stents. The sensors, shaped like stent cells, are fabricated from 28-μm thick foils of magnetoelastic Ni-Fe alloy and are conformally integrated with the stent. The typical sensitivity to viscosity is 427 ppm/cP over a 1.1-8.6 cP range. The sensitivity to mass loading is typically 63,000-65000 ppm/mg with resonant frequency showing an 8.1% reduction for an applied mass that is 15% of the unloaded mass of the sensor. © 2013 IEEE.

  6. In vitro imaging of coronary artery stents: Are there differences between 16- and 64-slice CT scanners?

    International Nuclear Information System (INIS)

    Wolf, Florian; Feuchtner, Gudrun M.; Homolka, Peter; Langenberger, Herbert; Stadler, Alfred; Bader, Till R.; Weber, Michael; Lammer, Johannes; Loewe, Christian

    2008-01-01

    Purpose: To compare the performance of 64-slice with 16-slice CT scanners for the in vitro evaluation of coronary artery stents. Methods and materials: Twelve different coronary artery stents were placed in the drillings of a combined heart and chest phantom, which was scanned with a 16- and 64-slice CT scanner. Coronal reformations were evaluated for artificial lumen narrowing, intraluminal attenuation values, and false widening of the outer stent diameter as an indicator of artifacts outside the stent. Results: Mean artificial lumen narrowing was not significantly different between the 16- and 64-slice CT scanner (44% versus 39%; p = 0.408). The differences between the Hounsfield Units (HU) measurements inside and outside the stents were significantly lower (p = 0.001) with 64- compared to 16-slice CT. The standard deviation of the HU measurements inside the stents was significantly (p = 0.002) lower with 64- than with 16-slice CT. Artifacts outside the stents were not significantly different between the scanners (p = 0.866). Conclusion: Visualization of the in-stent lumen is improved with 64-slice CT when compared with 16-slice CT as quantified by significantly lesser intraluminal image noise and less artificial rise in intraluminal HU measurement, which is the most important parameter for the evaluation of stent patency in vivo

  7. Comparison of Self-Expanding Polyethylene Terephthalate and Metallic Stents Implanted in Porcine Iliac Arteries

    International Nuclear Information System (INIS)

    Wilczek, Krzysztof; Scheerder, Ivan de; Wang Kai; Verbeken, Eric; Piessens, Jan

    1996-01-01

    Purpose: Comparison of the biocompatibility of self-expanding polyethylene terephthalate (PET) stents with self-expanding metallic stents (Wallstents). Methods: Diameter- and length-matched PET stents and Wallstents were symmetrically implanted in the paired iliac arteries of 13 crossbred domestic swine. Stent deployment was studied angiographically and with intravascular ultrasound immediately after stent implantation. The angiographic stented lumen diameter was measured using quantitative vessel analysis before, immediately after stenting, and at 6-week follow-up. Cross-section histopathology and area morphometry were performed. Results: Immediately poststenting, intravascular ultrasound revealed proximal dislocation of 5 of the 13 PET stents, whereas all metal stents were firmly embedded at the implantation site. At 6-week follow-up, three of the remaining PET stents were totally or subtotally occluded by organized thrombus, whereas all metal stents were patent. Compared with immediately poststenting, the angiographic lumen diameter within the five remaining PET stents was reduced by 30%, and that of the metallic stents was virtually unaltered (p < 0.02). This observation was confirmed by postmortem morphometry, wherein the PET-stented vessel segments a diameter stenosis of 40% was measured vs only 9% in the metallic stents (p < 0.0001). Conclusion: PET-stent deployment is difficult to control due to the lack of radiopacity of this stent. PET stents seem to be more thrombogenic and lead to significantly more neointimal proliferation than metallic stents

  8. Under X-ray guidance stent implantation through retrograde popliteal artery puncturing for the treatment of superficial femoral artery occlusion: the initial results in nine cases

    International Nuclear Information System (INIS)

    He Xu; Gu Jianping; Lou Wensheng; Chen Liang; Chen Guoping; Su Haobo; Song Jinhua; Wang Tao; Xu Ke

    2011-01-01

    Objective: To discuss the application of retrograde popliteal artery puncturing under X-ray guidance in the interventional therapy for superficial femoral artery occlusion. Methods: Retrograde popliteal artery puncturing under X-ray guidance was carried out in nine patients with long-segment occlusion of superficial femoral artery as antegrade recanalization via femoral artery approach had failed in them. After retrograde route was successfully established, the balloon dilation and subsequent stent placement for occluded vessel were performed. Results: The technical success was obtained in all patients. The occluded superficial femoral arteries were reopened and the symptoms of intermittent claudication disappeared. No serious complications such as injuries of adjacent nerves or vessels occurred. The ankle-brachial index (ABI) increased from preoperative (0.38±0.13) to postoperative (0.92±0.11) with the difference being statistically significant (P<0.01). A follow-up period lasting for 2-16 months was conducted. Eleven months after the treatment, intermittent claudication recurred in one case, and CT angiography showed that the distal part of the stent was narrowed. The symptoms were improved after percutaneous transcatheter angioplasty was performed again. Conclusion: Retrograde popliteal artery puncturing under X-ray guidance is an effective and safe technique for the treatment of superficial femoral artery long-segment occlusion with stent placement, especially for patients in whom antegrade recanalization via femoral artery approach fails. (authors)

  9. Late presenting, contained rupture of the superficial femoral artery following atherectomy and stenting: case report and literature review.

    Science.gov (United States)

    Clegg, Stacey; Aghel, Arash; Rogers, R Kevin

    2014-08-01

    Excisional atherectomy alone or followed by stenting is considered an appropriate treatment strategy for patients with lifestyle-limiting claudication due to obstructive infra-inguinal peripheral arterial disease (Ramaiah et al., J Endovasc Ther 2006;13:592-6021). We present a case of a 69-year-old man with eccentric severely calcified disease of the superficial femoral artery (SFA) treated with excisional atherectomy followed by stenting with an interwoven nitinol stent. The procedure was complicated by extravascular stent migration associated with a contained rupture presenting 30 days after the intervention. The complication was successfully treated with a stent graft. Although rare, pseudoaneurysms have been reported at the site of prior atherectomy; however, this case is the first description of a contained rupture post atherectomy associated with erosion of a nitinol stent into an extra-luminal position. The mechanism and management of this complication are discussed. © 2014 Wiley Periodicals, Inc.

  10. Nine-month Angiographic and Two-year Clinical Follow-up of Novel Biodegradable-polymer Arsenic Trioxide-eluting Stent Versus Durable-polymer Sirolimus-eluting Stent For Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Li Shen

    2015-01-01

    Full Text Available Background: Despite great reduction of in-stent restenosis, first-generation drug-eluting stents (DESs have increased the risk of late stent thrombosis due to delayed endothelialization. Arsenic trioxide, a natural substance that could inhibit cell proliferation and induce cell apoptosis, seems to be a promising surrogate of sirolimus to improve DES performance. This randomized controlled trial was to evaluate the efficacy and safety of a novel arsenic trioxide-eluting stent (AES, compared with traditional sirolimus-eluting stent (SES. Methods: Patients with symptoms of angina pectoris were enrolled and randomized to AES or SES group. The primary endpoint was target vessel failure (TVF, and the second endpoint includes rates of all-cause death, cardiac death or myocardial infarction, target lesion revascularization (TLR by telephone visit and late luminal loss (LLL at 9-month by angiographic follow-up. Results: From July 2007 to 2009, 212 patients were enrolled and randomized 1:1 to receive either AES or SES. At 2 years of follow-up, TVF rate was similar between AES and SES group (6.67% vs. 5.83%, P = 0.980. Frequency of all-cause death was significantly lower in AES group (0 vs. 4.85%, P = 0.028. There was no significant difference between AES and SES in frequency of TLR and in-stent restenosis, but greater in-stent LLL was observed for AES group (0.29 ± 0.52 mm vs. 0.10 ± 0.25 mm, P = 0.008. Conclusions: After 2 years of follow-up, AES demonstrated comparable efficacy and safety to SES for the treatment of de novo coronary artery lesions.

  11. Guidelines for patient selection and performance of carotid artery stenting.

    Science.gov (United States)

    Bladin, Christopher; Chambers, Brian; New, Gishel; Denton, Michael; Lawrence-Brown, Michael

    2010-06-01

    The endovascular treatment of carotid atherosclerosis with carotid artery stenting (CAS) remains controversial. Carotid endarterectomy remains the benchmark in terms of procedural mortality and morbidity. At present, there are no consensus Australasian guidelines for the safe performance of CAS. We applied a modified Delphi consensus method of iterative consultation between the College representatives on the Carotid Stenting Guidelines Committee (CSGC). Selection of patients suitable for CAS needs careful consideration of clinical and patho-anatomical criteria and cannot be directly extrapolated from clinical indicators for carotid endarterectomy (CEA). Randomized controlled trials (including pooled analyses of results) comparing CAS with CEA for treatment of symptomatic stenosis have demonstrated that CAS is more hazardous than CEA. On current evidence, the CGSC therefore recommends that CAS should not be performed in the majority of patients requiring carotid revascularisation. The evidence for CAS in patients with symptomatic severe carotid stenosis who are considered medically high risk is weak, and there is currently no evidence to support CAS as a treatment for asymptomatic carotid stenosis. The use of distal protection devices during CAS remains controversial with increased risk of clinically silent stroke. The knowledge requirements for the safe performance of CAS include an understanding of the evidence base from randomized controlled trials, carotid and aortic arch anatomy and pathology, clinical stroke syndromes, the differing treatment options for stroke and carotid atherosclerosis, and recognition and management of periprocedural complications. It is critical that all patients being considered for a carotid intervention have adequate pre-procedural neuro-imaging and an independent, standardized neurological assessment before and after the procedure. Maintenance of proficiency in CAS requires active involvement in surgical/endovascular audit and

  12. A new kind of 32P stent used for prevention of the restenosis after PTCA in rabbit iliac arteries

    International Nuclear Information System (INIS)

    Gao Dongsheng; Chen Runfen; Mao Jialiang; Huang Dingjiu

    2003-01-01

    Objective: To evaluate the effect and the mechanism of a new kind of 32 P stents used for prevention of the restenosis after percutaneous transluminal coronary angioplasty (PTCA); to observe the 'edge effect' caused by radioactive stents. Methods: Six 32 P-β-emitting stents made by compound plating, paired with 6 31 P nonradioactive(control) stents, were placed separately, one in one iliac artery in 6 rabbits, respectively. Animals were sacrificed after 30 d. Angiography, morphometry and immunohistochemistry work-up were performed. Results: There were no aneurysm or thrombosis in the arteries with stents placed. Morphometric measurements demonstrated that the mean minimum lumen diameter (MLD) was greater in 32 P stents than that in control stents (P 32 P stents was greater than that in control stents, but the later had marked neointimal area than the former (P 32 P-β-emitting stents made by compound plating could prevent in-stent restenosis significantly by inhibiting the neointimal growth even with low radioactivity; and it is safe, cheap and easy to make. But an unexpected increase in neointimal response, the so-called 'edge effect', was observed in the study

  13. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events

    DEFF Research Database (Denmark)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph

    2014-01-01

    eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. PRIMARY OUTCOMES: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite...... a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P... coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. CONCLUSIONS: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt...

  14. Current status of infrapopliteal artery stenting in patients with critical limb ischemia Estado atual do uso de stents na artéria infrapolítea em pacientes com isquemia crítica do membro

    Directory of Open Access Journals (Sweden)

    Marc Bosiers

    2008-09-01

    Full Text Available Due to the fear that early thrombosis and late luminal loss resulting from intimal hyperplasia might impede sustained patency of small-caliber arteries, such as those of the infrapopliteal bed, stent implantation in below-knee vessels remains controversial and is generally reserved for cases with a suboptimal outcome after percutaneous transluminal angioplasty (i.e. > 50% residual stenosis, flow-limiting dissection. Although evidence starts to build, favoring the use of stenting in the tibial area, results of well-conducted randomized controlled trials have to be awaited to change this strategy. Because of diameter similarities with coronary arteries, the first stents applied in the infrapopliteal vessels were all coronary devices. Once the feasibility of the stenting approach with these coronary products was shown, device manufacturers started to develop a dedicated infrapopliteal product range. To date, a broad spectrum of stent types has been used and investigated for the given indication. This article overviews the available literature and results of different balloon-expandable (bare metal, passive coated, drug eluting, self-expanding and absorbable stent types available for below-the-knee application and gives recommendations for future device technology advancements.Devido ao receio de que a trombose precoce ou a estenose tardia por hiperplasia intimal possam impedir a manutenção da perviedade em vasos de pequeno calibre, o uso de stents pós-angioplastia no leito arterial infrapoplíteo permanece controverso e geralmente é reservado aos casos de resultado subótimo após angioplastia transluminal percutânea (isto é, estenose residual > 50% ou dissecção com limitação do fluxo. Apesar de evidências começarem a favorecer o uso de stents no segmento tibial, é necessário aguardar o resultado de ensaios controlados, randomizados e bem conduzidos para mudar esta estratégia. Sendo estes vasos infrapoplíteos de diâmetro similar

  15. Enterprise stenting for intracranial aneurysm treatment induces dynamic and reversible age-dependent stenosis in cerebral arteries.

    Science.gov (United States)

    Gao, Bulang; Safain, Mina G; Malek, Adel M

    2015-04-01

    Although intracranial stenting has been associated with in-stent stenosis, the vascular response of cerebral vessels to the deployment of the Enterprise vascular reconstruction device is poorly defined. To evaluate the change in parent vessel caliber that ensues after Enterprise stent placement. Seventy-seven patients with 88 aneurysms were treated using Enterprise stent-assisted coil embolization and underwent high-resolution three-dimensional rotational angiography followed by three-dimensional edge-detection filtering to remove windowing-dependence measurement artifact. Orthogonal diameters and cross-sectional areas (CSAs) were measured proximal and distal on either side of the leading stent edge (points A, B), trailing stent edge (points D, E), and at mid-stent (point C). Enterprise stent deployment caused an instant increase in the parent artery CSA by 8.98% at D, which was followed 4-6 months later by significant in-stent stenosis (15.78% at A, 27.24% at B, 10.68% at C, 32.12% at D, and 28.28% at E) in the stented artery. This time-dependent phenomenon showed resolution which was complete by 12-24 months after treatment. This target vessel stenosis showed significant age dependence with greater response in the young. No flow-limiting stenosis requiring treatment was observed in this series. Use of the Enterprise stent is associated with a significant dynamic and spontaneously resolvable age-dependent in-stent stenosis. Further study is warranted on the clinical impact, if any, of this occurrence. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Engineering Radioactive Stents for the Prevention of Restenosis

    International Nuclear Information System (INIS)

    Bruce Thomadsen; Nickles, Robert J.; Larry DeWerd; Douglass Henderson; Jonathan Nye; Wes Culberson; Stephen Peterson; Michael Meltsner; Liyong Lin

    2004-01-01

    Radiation has become an accepted treatment for the prevention of restenosis (re-blockage) of coronary arteries following angioplasty. Radioactive stents could be the easiest method of delivery for the radiation, although clinical trials were disappointing. One likely reason was the choice of P-32 as the radionuclide, which fails to match the biological needs of the problem. What radionuclide would perform best remains unknown. This project established the physical infrastructure necessary for a rational investigation to determine the optimum radiological characteristics for radioactive stents in the prevention of restenosis following angioplasty. The project investigated methods to activate coronary stents with radionuclides that spanned a range of energies and radiation types that could provide a mapping of the biological response. The project also provided calibration methods to determine the strength of the stents, an a process to calculate the dose distribution actually delivered to the patient's artery--quantities necessary for any future scientific study to improve the effectiveness of radioactive stents. Such studies could benefit the thousands of patients who receive angioplasty each year

  17. Clinical effectiveness of secondary interventions for restenosis after renal artery stenting

    Science.gov (United States)

    Simone, Thomas A.; Brooke, Benjamin S.; Goodney, Philip P.; Walsh, Daniel B.; Stone, David H.; Powell, Richard J.; Cronenwett, Jack L.; Nolan, Brian W.

    2013-01-01

    Objective Secondary interventions for renal artery restenosis (RAS) after renal artery stenting are common, despite limited data about their effectiveness. This study was designed to evaluate the outcomes of endovascular treatment of recurrent RAS. Methods We conducted a retrospective review of patients who underwent renal artery stenting between 2001 and 2011 at Dartmouth-Hitchcock Medical Center. Patients who required secondary interventions were compared with control patients who underwent only primary interventions for RAS. Multivariate regression models were used to identify factors associated with successful outcomes, as measured by changes in blood pressure, estimated glomerular filtration rate, and number of antihypertensive medications required. Results Sixty-five secondary (57 patients) renal interventions were undertaken for recurrent RAS associated with progressive hypertension or renal dysfunction and compared with outcomes after 216 primary (180 patients) renal artery stenting procedures. Patients undergoing primary vs secondary interventions did not differ significantly in the number of preoperative antihypertensive medications used, comorbid conditions, or blood pressure. All primary and secondary interventions were performed with stents and showed no difference in procedural complications. At a mean follow-up of 23 months (range, 1–128 months), similar improvements in renal function and blood pressure were found between patients undergoing primary and secondary interventions, and there was no difference in rates of restenosis or survival between cohorts. Regression models showed that the use of embolic protection devices was associated with improved renal function after primary (odds ratio [OR], 2.0; 95% confidence interval [CI], 1.1–3.8; P < .05) and secondary (OR, 4.7; 95% CI, 1.7–12.5; P < .05) interventions, whereas statin therapy was associated with improved renal (OR, 2.0; 95% CI, 1.3–3.2; P < .05) and blood pressure response (OR, 4

  18. Use of Self-Expanding Stents for the Treatment of Vertebral Artery Ostial Stenosis: a Single Center Experience

    International Nuclear Information System (INIS)

    Chung, Sun Young; Lee, Deok Hee; Choi, Jin Woo; Choi, Byung Se; In, Hyun Sin; Kim, Sun Mi; Choi, Choong Gon; Kim, Sang Joon; Suh, Dae Chul

    2010-01-01

    To evaluate our early experience using self-expanding stents to treat atherosclerotic vertebral artery ostial stenosis (VAOS), with respect to technical feasibility and clinical and imaging follow-up results. A total of 20 lesions in 20 patients underwent stenting of the VAOS using a self-expanding stent (Precise RX; Cordis Neurovascular, Miami Lakes, FL). Two patients were asymptomatic. We analyzed the technical success rate, causes of technical failure, occurrence of any vascular or neurological event, and the occurrence of any neurological abnormality or in-stent restenosis (ISR) seen on follow-up. The imaging follow-up was performed with Doppler ultrasound (DUS) as a primary screening modality. One instance of technical failure was caused by failure of the guidewire passage. The stent diameter was 5 mm, and post-stenting balloon dilatations were necessary in all cases. Stent misplacement requiring placement of an additional stent occurred in four cases. Following a 14.8 month average clinical follow-up time, two patients showed anterior circulation ischemia, which was not attributed to the VAOS we treated. Following a 13.7 month average DUS follow-up, five patients showed a mild degree of diffuse or focal intimal thickening in the stent lumen; however, none of the stenosis showed luminal loss of more than 50% and no stent fracture was noted. The use of self-expanding stents for treating VAOS was technically feasible and helped to improve artery patency during our limited follow-up interval

  19. Duplex criteria for determination of in-stent stenosis after angioplasty and stenting of the superficial femoral artery.

    Science.gov (United States)

    Baril, Donald T; Rhee, Robert Y; Kim, Justine; Makaroun, Michel S; Chaer, Rabih A; Marone, Luke K

    2009-01-01

    Endovascular intervention is considered first-line therapy for most superficial femoral artery (SFA) occlusive disease. Duplex ultrasound (DU) criteria for SFA in-stent stenosis and correlation with angiographic data remain poorly defined. This study evaluated SFA-specific DU criteria for the assessment of SFA in-stent stenosis. From May 2003 to May 2008, 330 limbs underwent SFA angioplasty and stenting and were monitored by serial DU imaging. Suspected stenotic lesions underwent angiography and intervention when appropriate. Data pairs of DU and angiographically estimated stenosis or=50% in-stent stenosis, a PSV >or=190 had 88% sensitivity, 95% specificity, a 98% positive predictive value (PPV), and a 72% negative predictive value (NPV); for Vr, a ratio of >1.50 had 93% sensitivity, 89% specificity, a 96% PPV, and a 81% NPV. To detect >or=80% in-stent stenosis, a PSV >or=275 had 97% sensitivity, 68% specificity, a 67% PPV, and a 97% NPV; a Vr ratio >or=3.50 had 74% sensitivity, 94% specificity, a 77% PPV, and a 88% NPV. Combining a PSV >or=275 and a Vr >or=3.50 to determine >or=80% in-stent stenosis had 74% sensitivity, 94% specificity, a 88% PPV, and a 85% NPV; odds ratio was 42.17 (95% confidence interval, 10.20-174.36, P or=80% in-stent stenosis. A significant drop in ABI (>0.15) correlated with a >62% in-stent stenosis, although the adjusted correlation coefficients was low (R(2) = 0.31, P = .02). PSV and Vr appear to have a significant role in predicting in-stent stenosis. To determine >or=80% stenosis, combining PSV >or=275 cm/s and Vr >or=3.50 is highly specific and predictive.

  20. Intravascular ultrasound evaluation of a pseudolesion created by stent placement in the right artery.

    Science.gov (United States)

    Zientek, D M; Rodgers, G P

    1999-10-01

    The creation of a pseudolesion after guidewire placement in tortuous arterial segments is a well recognized phenomenon. Intravascular ultrasound has been useful in assessing deployment of intracoronary stents and equivocal angiographic findings. We present a case in which a pseudolesion was not observed until after placement of an intracoronary stent. Intravascular ultrasound demonstrated no dissection or significant lesion; however, there was focal calcification just distal to the stent providing a substrate for the distorted vessel architecture. The lesion resolved with removal of the guidewire.

  1. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

    Science.gov (United States)

    Lemos, Pedro A; Abizaid, Alexandre A C; Meireles, George C; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D; Mariani, Jose; Perin, Marco A; Costantini, Costantino; Costa, Ricardo A; Costa, José Ribamar; Chamie, Daniel; Campos, Carlos A; Ribeiro, Expedito

    2015-12-01

    To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. © 2015 John Wiley & Sons Ltd.

  2. EFFECT OF STENT ABSORBED c-myc ANTISENSE OLIGODEOXYNUCLEOTIDE ON SMOOTH MUSCLE CELLS APOPTOSIS IN RABBIT CAROTID ARTERY

    Institute of Scientific and Technical Information of China (English)

    张新霞; 崔长琮; 李江; 崔翰斌; 徐仓宝; 朱参战

    2002-01-01

    Objective To investigate the effect of gelatin coated Platinium-Iridium stent absorbed c-myc antisense oligodeoxynucleotide (ASODN) on smooth muscle cells apoptosis in a normal rabbit carotid arteries. Methods Gelatin coated Platinium-Iridium stents were implanted in the right carotid arteries of 32 rabbits under vision. Animals were randomly divided into control group and treated group receiving c-myc ASODN (n=16, respectively). On 7, 14, 30 and 90 days following the stenting procedure ,morphometry for caculation of neointimal area and mean neointimal thickness were performed.The expression of c-myc protein was detected by immunohistochemical method. Apoptotic smooth muscle cells was detected by terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL). Results At 7 and 14 days after stenting,there were no detectable apoptotic cells in both groups. The apoptotic cells occurred in the neointima 30 and 90 days after stenting, and the number of apoptotic cells at 30 days were less [4.50±1.29 vs 25.75±1.89 (number/0.1mm2)] than that at 90 days [13.50±1.91 vs 41.50±6.46 (number/0.1mm2)]. Meanwhile c-myc ASODN induced more apoptotic cells than the control group(P<0.0001). c-myc protein expression was weak positive or negative in treated group and positive in control group.Conclusion c-myc ASODN can induce smooth muscle cells apoptosis after stenting in normal rabbit carotid arteries,and it can be used to prevent in-stent restenosis.

  3. Cognitive changes after carotid artery stenting

    International Nuclear Information System (INIS)

    Grunwald, I.Q.; Politi, M.; Struffert, T.; Krick, C.; Backens, M.; Supprian, T.; Falkai, P.; Reith, W.

    2006-01-01

    We aimed to test changes in cognitive performance after carotid artery stenting (CAS). Ten patients were neuropsychologically tested at least 24 h before and 48 h after CAS. To diminish thromboembolic events, we used a proximal protection device. The following neuropsychological tests were selected: The Mini Mental State Examination (MMSE), symbol digit test and subtests of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) battery (verbal fluency, constructional practice, word list memory and delayed recall). Affective state was determined by the Beck Depression Score (BDS). No patient suffered from depression (BDS <1) or dementia (MMSE 29.9±1.5). Nine of the ten patients (P=0.12) showed increased speed in the Number Connection Test (NCT) (corresponding to trail making test). Most patients showed better or similar results concerning delayed recall (P=0.31). No change was observed in the symbol digit test, word list memory, verbal fluency or constructional practice. Better results concerning NCT and delayed recall after carotid stenting might be due to improved brain perfusion. After CAS, cognitive and memory performance seem to improve. Further studies with different time intervals and more refined testing, as well as perfusion-weighted imaging, are needed. (orig.)

  4. Satisfactory arterial repair 1 year after ultrathin strut biodegradable polymer sirolimus-eluting stent implantation: an angioscopic observation.

    Science.gov (United States)

    Ishihara, Takayuki; Awata, Masaki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Uematsu, Masaaki; Mano, Toshiaki

    2018-01-15

    The ultrathin strut biodegradable polymer sirolimus-eluting stent (Orsiro, O-SES) exhibits satisfactory clinical outcomes. However, no report to date has documented the intravascular status of artery repair after O-SES implantation. We examined 5 O-SES placed in 4 patients (age 65 ± 12 years, male 75%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed immediately after percutaneous coronary intervention and 1 year later. Angioscopic images were analyzed to determine the following: (1) dominant grade of neointimal coverage (NIC) over the stent; (2) maximum yellow plaque grade; and (3) existence of thrombus. Yellow plaque grade was evaluated both immediately after stent implantation and at the time of follow-up observation. The other parameters were evaluated at the time of follow-up examination. NIC was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. Yellow plaque severity was graded as: grade 0, white; grade 1, light yellow; grade 2, yellow; and grade 3, intensive yellow. Angioscopic findings at 1 year demonstrated the following: dominant NIC grade 1, grade 2, and grade 3 in 1, 2, and 2 stents, respectively; all stents were covered to some extent; focal thrombus adhesion was observed in only 1 stent. Yellow plaque grade did not change from immediately after stent implantation to follow-up. O-SES demonstrated satisfactory arterial repair 1 year after implantation.

  5. Coronary Artery Bypass Surgery Versus Drug-Eluting Stent Implantation for Left Main or Multivessel Coronary Artery Disease: A Meta-Analysis of Individual Patient Data.

    Science.gov (United States)

    Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W; Park, Seung-Jung

    2016-12-26

    The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD). The relative efficacy and safety of CABG versus PCI with DES for left main or multivessel CAD remain controversial. Data were pooled from the BEST (Randomized Comparison of Coronary Artery Bypass Surgery and Everolimus Eluting Stent Implantation in the Treatment of Patients With Multivessel Coronary Artery Disease), PRECOMBAT (Premier of Randomized Comparison of Bypass Surgery vs. Angioplasty Using Sirolimus-Eluting Stent in Patients With Left Main Coronary Artery Disease), and SYNTAX (Synergy Between PCI With Taxus and Cardiac Surgery) trials. The primary outcome was a composite of all-cause death, myocardial infarction, or stroke. The median follow-up was 60 months, and follow-up was completed for 96.2% of patients. The rate of primary outcome was significantly lower with CABG than with PCI (13.0% vs. 16.0%; hazard ratio [HR]: 0.83; 95% confidence interval [CI]: 0.69 to 1.00; p = 0.046). The difference was mainly driven by reduction in myocardial infarction (HR: 0.46; 95% CI: 0.33 to 0.64; p patients with multivessel CAD (p = 0.001), but no between-group difference in those with left main CAD (p = 0.427). The rates for all-cause death and stroke were similar between the 2 groups. By contrast, the need for repeat revascularization was significantly lower in the CABG group compared with the PCI group. CABG, as compared with PCI with DES, reduced long-term rates of the composite of all-cause death, myocardial infarction, or stroke in patients with left main or multivessel CAD. The advantage of CABG over PCI with DES was particularly pronounced in those with multivessel CAD. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  6. Assessment of a Polyester-Covered Nitinol Stent in the Canine Aorta and Iliac Arteries

    International Nuclear Information System (INIS)

    Castaneda, Flavio; Ball-Kell, Susan M.; Young, Kate; Li Ruizong

    2000-01-01

    Purpose: To evaluate the patency and healing characteristics of a woven polyester fabric-covered stent in the canine model.Methods: Twenty-four self-expanding covered stents were placed in the infrarenal aorta and bilateral common iliac arteries of eight dogs and evaluated at 1 (n = 2), 3 (n = 2), and 6 (n = 4) months. Stent assessment was done using angiography prior to euthanasia, and light and scanning electron microscopy.Results: Angiographically, just prior to euthanasia, 8 of 8 aortic and 14 of 16 iliac endovascular covered stents were patent. Histologically, the stented regions showed complete endothelialization 6 months after graft implantation. A neointima had formed inside the stented vessel regions resulting in complete encasement of the fabric-covered stent by 3 months after graft implantation. Medial compression with smooth muscle cell atrophy was present in all stented regions. Explanted stent wires, examined by scanning electron microscopy, showed pitting but no cracks or breakage.Conclusion: The covered stent demonstrated predictable healing and is effective in preventing stenosis in vessels 10.0 mm or greater in diameter but does not completely preclude stenosis in vessels 6.0 mm or less in diameter

  7. Direct Stenting in Patients with Acute Lower Limb Arterial Occlusions: Immediate and Long-Term Results

    International Nuclear Information System (INIS)

    Galanakis, Nikolaos; Kontopodis, Nikolaos; Peteinarakis, Ioannis; Kehagias, Elias; Ioannou, Christos V.; Tsetis, Dimitrios

    2017-01-01

    PurposeThe purpose of this study is to accentuate the efficacy of direct stenting (stent placement without predilatation of the lesion) in patients with acute lower limb arterial ischemia (ALLI).Materials and MethodsBetween January 2010 and September 2015, 16 patients (11 men and 5 women) underwent direct stenting of acute arterial occlusions. All patients had contraindication for surgical revascularization or catheter-directed thrombolysis. According to SVS/ISCVS Classification, six patients had IIa and ten patients IIb ALLI. The occlusions were located in CIA, EIA, SFA, or popliteal artery. Mean follow-up time with clinical examination and color Duplex ultrasonography was 37.6 months (range 1–72). We analyzed the technical and clinical outcomes of the procedures, as well the complications and patency rates.ResultsTechnical success was achieved in all patients (16/16) and there was significant clinical improvement in 15 patients. There was neither distal embolization nor procedure-related complications. During the 6 years of follow-up, four patients died due to non-procedure-related causes and there were two minor and one major amputations. The primary patency rates and the amputation-free survival rates were 93.7 and 87% at 1 year, 75.2 and 71.2% at 3 years, and 75.2 and 62.3%, respectively, at 6 years.ConclusionsDirect stenting may be a valuable alternative procedure for acute arterial occlusions in selected cases with high technical success and significant clinical improvement.Level of EvidenceLevel 4, Case Series.

  8. Direct Stenting in Patients with Acute Lower Limb Arterial Occlusions: Immediate and Long-Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Galanakis, Nikolaos [University of Crete Medical School, Interventional Radiology Unit, Department of Medical Imaging, University Hospital Heraklion (Greece); Kontopodis, Nikolaos [University of Crete Medical School, Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital Heraklion (Greece); Peteinarakis, Ioannis; Kehagias, Elias [University of Crete Medical School, Interventional Radiology Unit, Department of Medical Imaging, University Hospital Heraklion (Greece); Ioannou, Christos V. [University of Crete Medical School, Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital Heraklion (Greece); Tsetis, Dimitrios, E-mail: tsetis@med.uoc.gr [University of Crete Medical School, Interventional Radiology Unit, Department of Medical Imaging, University Hospital Heraklion (Greece)

    2017-02-15

    PurposeThe purpose of this study is to accentuate the efficacy of direct stenting (stent placement without predilatation of the lesion) in patients with acute lower limb arterial ischemia (ALLI).Materials and MethodsBetween January 2010 and September 2015, 16 patients (11 men and 5 women) underwent direct stenting of acute arterial occlusions. All patients had contraindication for surgical revascularization or catheter-directed thrombolysis. According to SVS/ISCVS Classification, six patients had IIa and ten patients IIb ALLI. The occlusions were located in CIA, EIA, SFA, or popliteal artery. Mean follow-up time with clinical examination and color Duplex ultrasonography was 37.6 months (range 1–72). We analyzed the technical and clinical outcomes of the procedures, as well the complications and patency rates.ResultsTechnical success was achieved in all patients (16/16) and there was significant clinical improvement in 15 patients. There was neither distal embolization nor procedure-related complications. During the 6 years of follow-up, four patients died due to non-procedure-related causes and there were two minor and one major amputations. The primary patency rates and the amputation-free survival rates were 93.7 and 87% at 1 year, 75.2 and 71.2% at 3 years, and 75.2 and 62.3%, respectively, at 6 years.ConclusionsDirect stenting may be a valuable alternative procedure for acute arterial occlusions in selected cases with high technical success and significant clinical improvement.Level of EvidenceLevel 4, Case Series.

  9. ANGIOPLASTIA PERCUTÁNEA CON STENT EN EL TRONCO PRINCIPAL DE LA ARTERIA CORONARIA IZQUIERDA / Percutaneous angioplasty with stent in the left main coronary artery

    Directory of Open Access Journals (Sweden)

    Javier Almeida Gómez

    2012-10-01

    Full Text Available ResumenIntroducción y objetivos: La afectación significativa del tronco común izquierdo, es la más letal de las presentaciones de la enfermedad arterial coronaria. El tratamiento de elección, es la cirugía de derivación aorto-coronaria. En varios estudios multicéntricos, se sugiere la posibilidad de tratar la enfermedad de tronco mediante el intervencionismo coronario percutáneo con implantación de prótesis endoluminal o stent. El objetivo de esta investigación fue caracterizar la angioplastia percutánea con stent en el tronco principal de la arteria coronaria izquierda. Método: Se realizó un estudio observacional, descriptivo y transversal en 21 pacientes con angioplastia percutánea con stent en el tronco principal de la arteria coronaria izquierda, realizadas en el laboratorio de Hemodinámica y Cardiología Intervencionista del Hospital "Hermanos Ameijeiras", entre enero 2010 y julio 2011. Resultados: No existió diferencia significativa en el sexo. Predominó el grupo de edad entre 50-64 años (47,6 % y el color de la piel blanca (76,19 %. El factor de riesgo cardiovascular más encontrado fue la HTA (85,71 %, seguido de dislipidemia (47,61 %. El diagnóstico más observado fue la angina de esfuerzo estable, 14 casos (66,66 %. La lesión en el cuerpo del tronco (12 pacientes, 57,1 %, fue la más encontrada, seguida de la ostial (8 casos. El tipo de stent más utilizado fue el liberador de fármacos (61,9 %, y solamente 4 pacientes presentaban troncos protegidos quirúrgicamente. Conclusiones: La mayor cantidad de casos fueron electivos, con predominio de los troncos no protegidos. El factor de riesgo coronario más encontrado fue la HTA. Se encontró asociación significativa entre la diabetes mellitus y la localización ostial de la lesión tratada. / AbstractIntroduction and Objectives: Significant impairment of the left main coronary artery is the most lethal presentation of coronary artery disease. The treatment of choice

  10. Toxic vessel reaction to an absorbable polymer-based paclitaxel-eluting stent in pig coronary arteries.

    Science.gov (United States)

    Jabara, Refat; Chronos, Nicolas; Tondato, Fernando; Conway, Damian; Molema, Warner; Park, Kenneth; Mabin, Tom; King, Spencer; Robinson, Keith

    2006-08-01

    The goal of this study was to evaluate a new drug-eluting stent (DES) comprising a bioabsorbable polymer eluting a moderate dose of paclitaxel in a clinically relevant animal model. Although DES limit restenosis, adverse vascular pathologies and toxicities continue to be of major concern. Optimization of DES components, especially completely absorbable polymers, may reduce these toxicities. Bare-metal (BM), absorbable polymer coating only (POLY), and polymer-based paclitaxel-eluting (PACL) stents were implanted in porcine coronary arteries using intravascular ultrasound (IVUS) to optimize stent apposition. The dose density of paclitaxel was 0.30-0.35 mcg/mm2, with in vitro elution studies demonstrating a gradual elution over 6-8 weeks. The animals were terminated at 1 week, 1 month and 3 months. Histopathologic and histomorphometric analyses were perform. The arteries with PACL showed extensive smooth muscle cell necrosis at 1 week and poor apposition of stent struts at 1 month (malapposition measured as gap width between strut and internal elastic lamina), with greater gap width compared to the BM and POLY groups (0.22 mm +/- 0.02 vs. 0.03 mm +/- 0.02 and 0.02 mm +/- 0.01, respectively; p stent malapposition and late neointimal thickening. Since the therapeutic window for paclitaxel may be narrower than currently inferred, thorough preclinical testing coupled with the polymer development process for stents eluting paclitaxel is needed.

  11. Predictors of Long-Term Results After Treatment of Iliac Artery Obliteration by Transluminal Angioplasty and Stent Deployment

    International Nuclear Information System (INIS)

    Funovics, M.A.; Lackner, B.; Cejna, M.; Peloschek, P.; Sailer, J.; Philipp, M.O.; Maca, T.; Ahmadi, A.; Minar, E.; Lammer, J.

    2002-01-01

    Purpose: To investigate initial and long-term success rate after percutaneous treatment of iliac artery occlusion with angioplasty and stent deployment. To investigate the influence of vascular comorbidity, lesion length, stent placement and lesion coverage as possible predictors of outcome. Methods: Between January 1994 and December 1999, 80 iliac recanalizations were performed on 78 patients, median age 61.1 ±11.5 (SD) years. All patients were followed up by clinical examinations, duplex ultrasound and intravenous digital subtraction angiography. Mean follow-up time was 2.0 ± 1.53 (SD) years.Multivariate Cox regression analysis was used to determine the influence of cofactors on patency. Results: One, 2 and 4 years after recanalization, primary patency was 78.1%, 74.5% and 64.0%; secondary patency was 88.8%, 88.8% and 77.9%, respectively.Patients with shorter occlusions, complete lesion coverage and patent ipsilateral femoral arteries had significantly longer patency rates.Complications included inguinal hematoma (n=1), technical failure (n=3) aortic dissection (n=1), embolic occlusions (n=7), gluteal claudication (n=1) and genital necrosis after subsequent urethral surgery in one patient with contralateral occlusion and ipsilateral overstenting of the internal iliac artery with subsequent stenosis. Complications were of permanent clinical significance in seven of 78 (9%) of the patients. In 17 (22%) cases, percutaneous reintervention was performed with angioplasty in the stent (n=16) or deployment of a new stent (n=1). Conclusion: Endoluminal stent placement has its place in an interdisciplinary therapeutic approach as a viable therapeutic alternative to major transabdominal bypass surgery and can be performed with comparable complication rates. Patients with short occlusions, patent femoral arteries, and stents covering the entire occlusion have significant longer patency

  12. Treatment of a Left Internal Mammary Artery to Pulmonary Artery Fistula with Polytetrafluoroethylene Covered Stents: A Case Report and Review of the Literature

    International Nuclear Information System (INIS)

    Abbott, J. Dawn; Brennan, Joseph J.; Remetz, Michael S.

    2004-01-01

    Internal mammary artery (IMA) to pulmonary artery (PA) fistula is a rare complication of coronary artery bypass grafting (CABG) that may present as myocardial ischemia. We describe a case of left IMA-to-PA fistula treated with balloon expandable coronary polytetrafluoroethylene (PTFE) graft stents and review previously reported cases of this entity

  13. Fluid-attenuated inversion recovery vascular hyperintensities in predicting cerebral hyperperfusion after intracranial arterial stenting

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Chih-Cheng; Chen, David Yen-Ting; Tseng, Ying-Chi; Lee, Kun-Yu; Chiang, Chen-Hua; Chen, Chi-Jen [Taipei Medical University, Department of Radiology, Shuang-Ho Hospital, New Taipei City (China); Taipei Medical University, School of Medicine, College of Medicine, Taipei (China); Yan, Feng-Xian [Taipei Medical University, Department of Radiology, Shuang-Ho Hospital, New Taipei City (China)

    2017-08-15

    No reliable imaging sign predicting cerebral hyperperfusion after intracranial arterial stenting (IAS) had been described in the literature. This study evaluated the effect of fluid-attenuated inversion recovery vascular hyperintensities (FVHs), also called hyperintense vessel sign on T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) MR images, in predicting significant increase in cerebral blood flow (CBF) defined by arterial spin labeling (ASL) after IAS. We reviewed ASL CBF images and T2-FLAIR MR images before (D0), 1 day after (D1), and 3 days after (D3) IAS of 16 patients. T1-weighted MR images were used as cerebral maps for calculating CBF. The changes in CBF values after IAS were calculated in and compared among stenting and nonstenting vascular territories. An increase more than 50% of CBF was considered as hyperperfusion. The effect of FVHs in predicting hyperperfusion was calculated. The D1 CBF value was significantly higher than the D0 CBF value in stenting vascular, contralateral anterior cerebral artery, contralateral middle cerebral artery, and contralateral posterior cerebral artery (PCA) territories (all P <.05). The D1 and D3 CBF values were significantly higher than the D0 CBF value in overall vascular (P <.001), overall nonstenting vascular (P <.001), and ipsilateral PCA (P <.05) territories. The rate of more than 50% increases in CBF was significantly higher in patients who exhibited asymmetric FVHs than in those who did not exhibit these findings. FVHs could be a critical predictor of a significant increase in CBF after IAS. (orig.)

  14. Fluid-attenuated inversion recovery vascular hyperintensities in predicting cerebral hyperperfusion after intracranial arterial stenting

    International Nuclear Information System (INIS)

    Wan, Chih-Cheng; Chen, David Yen-Ting; Tseng, Ying-Chi; Lee, Kun-Yu; Chiang, Chen-Hua; Chen, Chi-Jen; Yan, Feng-Xian

    2017-01-01

    No reliable imaging sign predicting cerebral hyperperfusion after intracranial arterial stenting (IAS) had been described in the literature. This study evaluated the effect of fluid-attenuated inversion recovery vascular hyperintensities (FVHs), also called hyperintense vessel sign on T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) MR images, in predicting significant increase in cerebral blood flow (CBF) defined by arterial spin labeling (ASL) after IAS. We reviewed ASL CBF images and T2-FLAIR MR images before (D0), 1 day after (D1), and 3 days after (D3) IAS of 16 patients. T1-weighted MR images were used as cerebral maps for calculating CBF. The changes in CBF values after IAS were calculated in and compared among stenting and nonstenting vascular territories. An increase more than 50% of CBF was considered as hyperperfusion. The effect of FVHs in predicting hyperperfusion was calculated. The D1 CBF value was significantly higher than the D0 CBF value in stenting vascular, contralateral anterior cerebral artery, contralateral middle cerebral artery, and contralateral posterior cerebral artery (PCA) territories (all P <.05). The D1 and D3 CBF values were significantly higher than the D0 CBF value in overall vascular (P <.001), overall nonstenting vascular (P <.001), and ipsilateral PCA (P <.05) territories. The rate of more than 50% increases in CBF was significantly higher in patients who exhibited asymmetric FVHs than in those who did not exhibit these findings. FVHs could be a critical predictor of a significant increase in CBF after IAS. (orig.)

  15. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar

    2014-01-01

    BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...

  16. Zotarolimus-eluting stent for the treatment of recurrent, severe carotid artery in-stent stenosis in the TARGET-CAS population.

    Science.gov (United States)

    Tekieli, Lukasz; Pieniazek, Piotr; Musialek, Piotr; Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Trystula, Mariusz; Moczulski, Zbigniew; Dzierwa, Karolina; Paluszek, Piotr; Podolec, Piotr

    2012-06-01

    To evaluate the safety and efficacy of a balloon-mounted drug-eluting stent (DES) for recurrent carotid in-stent stenosis (ISS). As part of our targeted carotid artery stenting (TARGET-CAS) protocol, neurological and ultrasound evaluations have been performed at 3, 6, and 12 months and then annually since 2001 in all carotid stent patients. For angiographically-confirmed >70% ISS, balloon angioplasty was performed as a first-line treatment. Recurrent ISS was treated with a 4.0-mm zotarolimus-eluting coronary stent (ZES) that was postdilated according to intravascular ultrasound imaging. Among the 1350 neuroprotected CAS procedures performed between January 2001 and March 2011, there were 7 (0.52%) patients (5 men; ages 51-72 years), all neurologically asymptomatic, with >70% recurrent ISS that occurred at 5 to 11 months after the initial balloon angioplasty treatment for ISS. ZES implantation under distal embolic protection was technically successful and uncomplicated. Angiographic stenosis was reduced from 84.6%±7.5% to 10.7%±3.6% (p<0.01). In 5 patients with ZES implanted fully within the self-expanding carotid stent, duplex ultrasound follow-up (mean 17 months, range 6-36) revealed no evidence of restenosis or stent fracture/deformation. In the 2 other patients, the ZES had been implanted for distal edge ISS such that the ZES protruded beyond the original carotid stent. This protruding segment of the ZES demonstrated deformation/kinking in both; in one, this led to symptomatic stent occlusion. The use of coronary ZES in the treatment of recurrent carotid ISS is feasible and appears effective provided the ZES is placed entirely within the original stent. Placement of a coronary ZES outside the carotid stent scaffold should be avoided.

  17. Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials

    DEFF Research Database (Denmark)

    Tanimoto, Shuzou; Serruys, Patrick W; Thuesen, Leif

    2007-01-01

    OBJECTIVES: This study sought to evaluate and compare in vivo acute stent recoil of a novel bioabsorbable stent and a metallic stent. BACKGROUND: The bioabsorbable everolimus-eluting coronary stent (BVS) is composed of a poly-L-lactic acid backbone, coated with a bioabsorbable polymer containing...... the antiproliferative drug, everolimus, and expected to be totally metabolized and absorbed in the human body. Because the BVS is made from polymer, it may have more acute recoil than metallic stents in vivo. METHODS: A total of 54 patients, who underwent elective stent implantation for single de novo native coronary...... artery lesions, were enrolled: 27 patients treated with the BVS and 27 patients treated with the everolimus-eluting cobalt chromium stent (EES). Acute absolute recoil, assessed by quantitative coronary angiography, was defined as the difference between mean diameter of the last inflated balloon...

  18. Association between age and risk of stroke or death from carotid endarterectomy and carotid stenting : A meta-analysis of pooled patient data from four randomised trials

    NARCIS (Netherlands)

    Howard, George; Roubin, Gary S.; Jansen, Olav; Hendrikse, Jeroen; Halliday, Alison; Fraedrich, Gustav; Eckstein, Hans Henning; Calvet, David; Bulbulia, Richard; Bonati, Leo H.; Becquemin, Jean Pierre; Algra, Ale; Brown, Martin M.; Ringleb, Peter A.; Brott, Thomas G.; Mas, Jean Louis

    2016-01-01

    Background: Age was reported to be an effect-modifier in four randomised controlled trials comparing carotid artery stenting (CAS) and carotid endarterectomy (CEA), with better CEA outcomes than CAS outcomes noted in the more elderly patients. We aimed to describe the association of age with

  19. Treatment of traumatic internal carotid artery pseudoaneurysms with willis covered stents: a midterm follow-up result

    International Nuclear Information System (INIS)

    Wang Wu; Li Minghua; Li Yongdong; Gu Binxian; Fang Chun; Tan Huaqiao; Wang Ju; Zhang Peilei

    2010-01-01

    Objective: To evaluate the efficacy and mid-term follow-up results of endovascular treatment with Willis covered stent for traumatic pseudoaneurysms located in the internal carotid artery (ICA). Methods: ICA angiography was performed in 38 patients with traumatic brain and neck injury. Of the 38 patients, 13 delayed traumatic pseudoaneurysms were found. All the pseudoaneurysms were treated with Willis covered stents. Follow-up angiography was performed at 1, 3, 6 and 12 months after the procedure, and the results were categorized as complete or incomplete occlusion. Clinical manifestations were graded as full recovery, improvement, unchanged and aggravation. Results: Willis covered stent placement was technically successful in all traumatic pseudoaneurysms. No procedure-related complications occurred. The initial angiographic results showed a complete occlusion in 9 patients, and an incomplete occlusion in 4. The angiographic follow-up within 3-12 months exhibited a complete occlusion in 12 patients and the parent arteries remained patency in all patients. The clinical follow-up observation demonstrated that full recovery was obtained in 11 patients, clinical improvement in one, and unchanged condition in one. No morbidity or mortality occurred. Conclusion: Willis covered stent implantation is a feasible and practical treatment for traumatic pseudoaneurysms located in the ICA. This technique can well preserve the parent artery with excellent therapeutic results. (authors)

  20. [Technical feasibility of the implantation of a monorail stent system into the renal arteries without pre-dilatation].

    Science.gov (United States)

    Neumann, C; Gschwendtner, M; Karnel, F; Mair, J; Dorffner, G; Dorffner, R

    2005-01-01

    To evaluate the technical feasibility of the implantation of the monorail RX Herculink system into the renal arteries without pre-dilatation. Forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink stent. The mean grade of the stenosis was 83.8 %, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). In 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30 % were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 +/- 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 +/- 0.0. Implantation of the RX Herculink stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies.

  1. Predictors of antegrade flow at internal carotid artery during carotid artery stenting with proximal protection.

    Science.gov (United States)

    Harada, Kei; Kakumoto, Kosuke; Oshikata, Shogo; Fukuyama, Kozo

    2018-06-01

    Carotid artery stenting (CAS) with proximal occlusion effectively prevent distal cerebral embolism by flow arrest at internal carotid artery (ICA); however, the method can expose antegrade flow at ICA due to incomplete flow arrest. The aim of this study was to identify predictors of antegrade flow during CAS with proximal protection. We retrospectively analyzed clinical and angiographic data among 143 lesions treated with CAS with proximal protection by occluding the common carotid artery (CCA) and external carotid artery (ECA). Flow arrest or antegrade flow at ICA was confirmed by contrast injection during proximal protection. Antegrade flow at ICA was observed in 12 lesions (8.4%). Compared with lesions in which flow arrest of ICA was achieved, the diameter of the superior thyroid artery (STA) was significantly larger (2.4 ± 0.34 vs. 1.4 ± 0.68 mm, p protection should be combined with proximal protection for the lesions with antegrade flow to prevent distal migration of the carotid debris.

  2. A Novel Stent Coated with Antibodies to Endoglin Inhibits Neointimal Formation of Porcine Coronary Arteries

    Directory of Open Access Journals (Sweden)

    Song Cui

    2014-01-01

    Full Text Available Endoglin/CD105 is an accessory protein of the transforming growth factor-β receptor system that plays a critical role in proliferation of endothelial cells and neovasculature. Here, we aimed to assess the effect of novel stents coated with antibodies to endoglin (ENDs on coronary neointima formation. Thirty ENDs, thirty sirolimus-eluting stents (SESs, and thirty bare metal stents (BMSs were randomly assigned and placed in the coronary arteries in 30 juvenile pigs. Histomorphometric analysis and scanning electron microscopy were performed after stent implantation. Our results showed that after 7 days, there was no difference in the neointimal area and percent area stenosis in ENDs compared with SMSs or BMSs. After 14 days, the neointima area and percent area stenosis in ENDs were markedly decreased than those in BMSs or SESs (P<0.05. Moreover, the percentage of reendothelialization was significantly higher in ENDs than that in SESs or BMSs (P<0.01 at 7 and 14 days. The artery injury and the inflammation scores were similar in all groups at 7 and 14 days. In conclusion, our results demonstrated for the first time to our knowledge that endoglin antibody-coated stents can markedly reduce restenosis by enhancing reendothelialization in the porcine model and potentially offer a new approach to prevent restenosis.

  3. Triple antithrombotic therapy in patients with atrial fibrillation undergoing coronary artery stenting: hovering among bleeding risk, thromboembolic events, and stent thrombosis

    Directory of Open Access Journals (Sweden)

    Menozzi Mila

    2012-10-01

    Full Text Available Abstract Dual antiplatelet treatment with aspirin and clopidogrel is the antithrombotic treatment recommended after an acute coronary syndrome and/or coronary artery stenting. The evidence for optimal antiplatelet therapy for patients, in whom long-term treatment oral anticoagulation is mandatory, is however scarce. To evaluate the safety and efficacy of the various antithrombotic strategies adopted in this population, we reviewed the available evidence on the management of patients receiving oral anticoagulation, such as a vitamin-k-antagonists, referred for coronary artery stenting. Atrial fibrillation is the most frequent indication for oral anticoagulation. The need of starting antiplatelet therapy in this clinical scenario raises concerns about the combination to choose: triple therapy with warfarin, aspirin, and a thienopyridine being the most frequent and advised. The safety of this regimen appeared suboptimal because of an increased risk in hemorrhagic complications. On the other hand, the combination of oral anticoagulation and an antiplatelet agent is suboptimal in preventing thromboembolic events and stent thrombosis; dual antiplatelet therapy may be considered only when a high hemorrhagic risk and low thromboembolic risk are perceived. Indeed, the need for prolonged multiple-drug antithrombotic therapy increases the bleeding risks when drug eluting stents are used. Since current evidence derives mainly from small, single-center and retrospective studies, large-scale prospective multicenter studies are urgently needed.

  4. Metallic stent implantation in patients with iliac artery occlusion: long-term patency rate and factors related to recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Seok Kyun; Kim, Jae Kyu; Yoon, Woong; Kim, Jeong; Park, Jin Gyoon; Kang, Heoung Keun; Choi, Soo JinNa [Chonnam National University Hospital School of Medicine, Gwangju (Korea, Republic of)

    2003-09-01

    To determine the long-term patency rate in 68 patients with iliac artery occlusion who underwent metallic stent implantation, and to analyze the factors related to recurrence. Sixty-eight patients with occlusive disease of the iliac artery underwent implantation of a self-expandable metallic stent. The clinical symptoms were intermittent claudication (n=48), resting pain (n=11), and gangrene (n=9). Stent patency was determined by follow-up angiography and color Doppler imaging, and the cumulative patency rate using the Kaplan-Meier method. Cox's proportional hazard model was used to analyse recurrence-related factors involving clinical symptoms (Fontaine stage), risk factors, and anatomical factors such as lesion location, length, and the development of collaterals. The duration of follow-up varied from 1 day to 73 months (mean, 23.8 months). Arterial occlusion recurred in 16 of 68 patients (23.5%), and the cumulative patency rate was as follows: 95.4% at one month, 93.2% at six months, 80.1% at one year, 73.2% at two years, 68.9% at three years, and 62% at five years. According to a statistical analysis of risk factors, the recurrence (p=0.04) than in those without it, but in patients who smoked, hypertension, DM, and previous cerebrovascular disease were not statistically significant. With regard to anatomical factors, the recurrent rate for lesions involving the external iliac artery was 6.5 times higher (p=0.02) than for those involving the common iliac artery. Variations in the fontaine stage were not statistically significant indicators of recurrence. The recurrence rate after implantation of an iliac artery stent is higher in patients with heart disease than in those without it, and higher for occlusive lesions involving the external iliac artery than for those of the common iliac artery.

  5. Metallic stent implantation in patients with iliac artery occlusion: long-term patency rate and factors related to recurrence

    International Nuclear Information System (INIS)

    Chung, Seok Kyun; Kim, Jae Kyu; Yoon, Woong; Kim, Jeong; Park, Jin Gyoon; Kang, Heoung Keun; Choi, Soo JinNa

    2003-01-01

    To determine the long-term patency rate in 68 patients with iliac artery occlusion who underwent metallic stent implantation, and to analyze the factors related to recurrence. Sixty-eight patients with occlusive disease of the iliac artery underwent implantation of a self-expandable metallic stent. The clinical symptoms were intermittent claudication (n=48), resting pain (n=11), and gangrene (n=9). Stent patency was determined by follow-up angiography and color Doppler imaging, and the cumulative patency rate using the Kaplan-Meier method. Cox's proportional hazard model was used to analyse recurrence-related factors involving clinical symptoms (Fontaine stage), risk factors, and anatomical factors such as lesion location, length, and the development of collaterals. The duration of follow-up varied from 1 day to 73 months (mean, 23.8 months). Arterial occlusion recurred in 16 of 68 patients (23.5%), and the cumulative patency rate was as follows: 95.4% at one month, 93.2% at six months, 80.1% at one year, 73.2% at two years, 68.9% at three years, and 62% at five years. According to a statistical analysis of risk factors, the recurrence (p=0.04) than in those without it, but in patients who smoked, hypertension, DM, and previous cerebrovascular disease were not statistically significant. With regard to anatomical factors, the recurrent rate for lesions involving the external iliac artery was 6.5 times higher (p=0.02) than for those involving the common iliac artery. Variations in the fontaine stage were not statistically significant indicators of recurrence. The recurrence rate after implantation of an iliac artery stent is higher in patients with heart disease than in those without it, and higher for occlusive lesions involving the external iliac artery than for those of the common iliac artery

  6. Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice.

    Science.gov (United States)

    Simsekyilmaz, Sakine; Liehn, Elisa A; Weinandy, Stefan; Schreiber, Fabian; Megens, Remco T A; Theelen, Wendy; Smeets, Ralf; Jockenhövel, Stefan; Gries, Thomas; Möller, Martin; Klee, Doris; Weber, Christian; Zernecke, Alma

    2016-01-01

    Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal) were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs) and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE-/- carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches.

  7. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).

    Science.gov (United States)

    Ormiston, John; Webster, Mark; Stewart, James; Vrolix, Mathias; Whitbourn, Robert; Donohoe, Dennis; Knape, Charlene; Lansky, Alexandra; Attizzani, Guilherme F; Fitzgerald, Peter; Kandzari, David E; Wijns, William

    2013-10-01

    This first-in-human multicenter study sought to examine prospectively the safety and efficacy of a new, cobalt chromium thin-strut, coronary absorbable polymer-coated, sirolimus-eluting stent. Bioabsorbable polymers on drug-eluting stents may lower the long-term risks of inflammation, delayed healing, and adverse events. We enrolled patients with symptomatic coronary artery disease with stable or unstable angina pectoris and >50% diameter stenosis, amenable to coverage with a ≤23-mm long stent in a vessel 2.5 to 3.5 mm in diameter. All patients received dual antiplatelet therapy after implantation. Patients, in groups of 10, underwent repeat angiography, intravascular ultrasound, and optical coherence tomography at 4, 6, or 8 months, and all patients were seen or contacted at 18 months of follow-up. The median (range) in-stent late lumen loss (LLL) was 0.03 mm (-0.22 to 0.21 mm), 0.10 mm (-0.03 to 1.2 mm), and 0.08 mm (-0.01 to 0.28 mm), at 4, 6, and 8 months, respectively. At 18 months, the median in-stent LLL was 0.08 mm (-0.30 to 0.46 mm). On optical coherence tomography, the proportion of uncovered stent struts decreased from a median of 7.3% (range 0.4% to 46.3%) at 4 months to 0% (range: 0% to 3.4%) at 18 months. The percentage of neointimal volume obstruction by intravascular ultrasound increased from a median of 5.3% to 9.1% between 4 and 6 months and remained nearly unchanged thereafter through 18 months of follow-up. The only recorded major adverse cardiac event was a myocardial infarction. At 18 months of follow-up, this absorbable polymer-coated, cobalt chromium sirolimus-eluting stent was associated with a low and stable in-stent LLL, complete strut coverage, and no stent thrombosis. (First-In-Human Trial of the MiStent Drug-Eluting Stent [DES] in Coronary Artery Disease [DESSOLVE-I]; NCT01247428). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Stent Thrombosis With Drug-Eluting Stents and Bioresorbable Scaffolds: Evidence From a Network Meta-Analysis of 147 Trials.

    Science.gov (United States)

    Kang, Si-Hyuck; Chae, In-Ho; Park, Jin-Joo; Lee, Hak Seung; Kang, Do-Yoon; Hwang, Seung-Sik; Youn, Tae-Jin; Kim, Hyo-Soo

    2016-06-27

    This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS. To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS). Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year. A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization. Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices. Copyright © 2016 American College of Cardiology Foundation. Published by

  9. Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience.

    Science.gov (United States)

    Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan

    2015-10-01

    Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment.

  10. Cognitive changes after carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Politi, M.; Struffert, T.; Krick, C.; Backens, M. [University of the Saarland, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Supprian, T.; Falkai, P.; Reith, W. [University of the Saarland, Clinic for Psychiatry and Psychotherapy, Homburg (Germany)

    2006-05-15

    We aimed to test changes in cognitive performance after carotid artery stenting (CAS). Ten patients were neuropsychologically tested at least 24 h before and 48 h after CAS. To diminish thromboembolic events, we used a proximal protection device. The following neuropsychological tests were selected: The Mini Mental State Examination (MMSE), symbol digit test and subtests of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) battery (verbal fluency, constructional practice, word list memory and delayed recall). Affective state was determined by the Beck Depression Score (BDS). No patient suffered from depression (BDS <1) or dementia (MMSE 29.9{+-}1.5). Nine of the ten patients (P=0.12) showed increased speed in the Number Connection Test (NCT) (corresponding to trail making test). Most patients showed better or similar results concerning delayed recall (P=0.31). No change was observed in the symbol digit test, word list memory, verbal fluency or constructional practice. Better results concerning NCT and delayed recall after carotid stenting might be due to improved brain perfusion. After CAS, cognitive and memory performance seem to improve. Further studies with different time intervals and more refined testing, as well as perfusion-weighted imaging, are needed. (orig.)

  11. Comparison of femoropopliteal artery stents under axial and radial compression, axial tension, bending, and torsion deformations.

    Science.gov (United States)

    Maleckis, Kaspars; Deegan, Paul; Poulson, William; Sievers, Cole; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2017-11-01

    High failure rates of Peripheral Arterial Disease (PAD) stenting appear to be associated with the inability of certain stent designs to accommodate severe biomechanical environment of the femoropopliteal artery (FPA) that bends, twists, and axially compresses during limb flexion. Twelve Nitinol stents (Absolute Pro, Supera, Lifestent, Innova, Zilver, Smart Control, Smart Flex, EverFlex, Viabahn, Tigris, Misago, and Complete SE) were quasi-statically tested under bench-top axial and radial compression, axial tension, bending, and torsional deformations. Stents were compared in terms of force-strain behavior, stiffness, and geometrical shape under each deformation mode. Tigris was the least stiff stent under axial compression (6.6N/m axial stiffness) and bending (0.1N/m) deformations, while Smart Control was the stiffest (575.3N/m and 105.4N/m, respectively). Under radial compression Complete SE was the stiffest (892.8N/m), while Smart Control had the lowest radial stiffness (211.0N/m). Viabahn and Supera had the lowest and highest torsional stiffness (2.2μNm/° and 959.2μNm/°), respectively. None of the 12 PAD stents demonstrated superior characteristics under all deformation modes and many experienced global buckling and diameter pinching. Though it is yet to be determined which of these deformation modes might have greater clinical impact, results of the current analysis may help guide development of new stents with improved mechanical characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Peri-procedural complications and associated risk factors in wingspan stent-assistant angioplasty of intracranial artery stenosis

    International Nuclear Information System (INIS)

    Li Zhaoshuo; Li Tianxiao; Wang Ziliang; Bai Weixing; Xue Jiangyu; Zhu Liangfu; Li Li

    2013-01-01

    Objective: To retrospectively evaluate the cerebrovascular complications from stenting for symptomatic intracranial stenosis and to detect the factors associated with complications. Methods: Medical records of Wingspan stenting were reviewed for 306 cases with symptomatic intracranial stenosis from July 2007 to February 2012, including transient ischemic attack, ischemic stroke, death and intracranial hemorrhage as clinical in-hospital complications. The location of lesions included middle cerebral artery level M1 (114 lesions), intracranial portion of the internal carotid artery (50 lesions), vertebral artery 4 (75 lesions), venebro-basilar artery (14 lesions), basilar artery (76 lesions). Complications were evaluated and analyzed to find out whether they were associated with patient-or stenosis-related risk factors using χ"2 test. Results: The technical success rate was 99% (303/306). Cerebrovascular complications rate was 6.9% (21/303), with 1.6% (14/303) of disabling stroke events and 0.7% (2/303) of deaths. Hemorrhagic events were consisted of procedure-related events (3 cases), hyperperfusion (3 cases), ischemic events of perforator stroke (8 cases), transient ischemic attack (3 cases), embolization (2 cases), thrombosis in stent (2 cases). Hemorrhagic events were associated with significantly higher morbidity and mortality rates (χ"2 = 2.908, P < 0.05) and occurred more frequently after treatment of middle cerebral artery stenosis than other lesions (χ"2 = 1.168, P < 0.05). Perforating branches were detected to be affected mainly in the basilar artery than other locations (χ"2 = 4.263, P < 0.05). Conclusion: The complication rates in the study are preliminary consistent with the previously published data. Hemorrhagic events are prone to occur in the treatment of middle cerebral artery stenosis, while perforating branches are affected mainly in the basilar artery. (authors)

  13. Extracranial Carotid Artery Stenting in Surgically High-Risk Patients Using the Carotid Wallstent Endoprosthesis:Midterm Clinical and Ultrasound Follow-Up Results

    International Nuclear Information System (INIS)

    Maleux, Geert; Bernaerts, Pauwel; Thijs, Vincent; Daenens, Kim; Vaninbroukx, Johan; Fourneau, Inge; Nevelsteen, Andre

    2003-01-01

    The purpose of this study was to evaluate the feasibility, safety and midterm outcome of elective implantation of the Carotid Wallstent (registered) in patients considered to be at high surgical risk. In a prospective study, 54 carotid artery stenoses in 51 patients were stented over a 24-month period. Three patients underwent bilateral carotid artery stenting. Institutional inclusion criteria for invasive treatment of carotid occlusive disease (carotid endarterectomy or carotid artery stenting) are patients presenting with a 70% or more symptomatic stenosis and those with an 80% or more asymptomatic stenosis having a life-expectancy of more than 1 year. All patients treated by carotid artery stenting were considered at high risk for carotid endarterectomy because of a hostile neck (17 patients-31.5%) or because of severe comorbidities (37 patients-68.5%). No cerebral protection device was used. Of the 54 lesions, 33 (61.1%) were symptomatic and 21 (38.8%) were asymptomatic. Follow-up was performed by physical examination and by duplex ultrasonography at 1 month, 6 months, 1 year and 2 years after the procedure. All 54 lesions could be stented successfully without periprocedural stroke. Advert events during follow-up (mean 13.9 ± 5.7 months) were non-stroke-related death in 6 patients (11.1%), minor stroke in 4 stented hemispheres(7.4%), transient ipsilateral facial pain in 1 patient (1.8%),infection of the stented surgical patch in 1 patient (1.8%) and asymptomatic in stent restenosis in 4 patients (7.4%). The percutaneous implantation of the Carotid Wallstent (registered) , even without cerebral protection device, appears to be a safe procedure with acceptable clinical and ultrasonographic follow-up results in patients at high surgical risk. But some late adverse events such as ipsilateral recurrence of non-disabling (minor) stroke or in stent restenosis still remain real challenging problems

  14. [Measurements of blood velocities using duplex sonography in carotid artery stents: analysis of reliability in an in-vitro model and computational fluid dynamics (CFD)].

    Science.gov (United States)

    Schönwald, U G; Jorczyk, U; Kipfmüller, B

    2011-01-01

    Stents are commonly used for the treatment of occlusive artery diseases in carotid arteries. Today, there is a controversial discussion as to whether duplex sonography (DS) displays blood velocities (BV) that are too high in stented areas. The goal of this study was to evaluate the effect of stenting on DS with respect to BV in artificial carotid arteries. The results of computational fluid dynamics (CFD) were also used for the comparison. To analyze BV using DS, a phantom with a constant flow (70 cm/s) was created. Three different types of stents for carotid arteries were selected. The phantom fluid consisted of 67 % water and 33 % glycerol. All BV measurements were carried out on the last third of the stents. Furthermore, all test runs were simulated using CFD. All measurements were statistically analyzed. DS-derived BV values increased significantly after the placement of the Palmaz Genesis stent (77.6 ± 4.92 cm/sec, p = 0.03). A higher increase in BV values was registered when using the Precise RX stent (80.1 ± 2.01 cm/sec, p CFD simulations showed similar results. Stents have a significant impact on BV, but no effect on DS. The main factor of the blood flow acceleration is the material thickness of the stents. Therefore, different stents need different velocity criteria. Furthermore, the results of computational fluid dynamics prove that CFD can be used to simulate BV in stented silicone tubes. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Stent impact on the geometry of the carotid bifurcation and the course of the internal carotid artery

    International Nuclear Information System (INIS)

    Berkefeld, J.; Zanella, F.E.; Rosendahl, H.; Theron, J.G.; Guimaraens, L.; Treggiari-Venzi, M.M.

    2002-01-01

    A measurement system is proposed to evaluate reconstructive effects of carotid stents on the geometry of the carotid bifurcation and the course of the internal carotid artery. To describe deviations of the stenotic internal carotid artery (ICA) from the extended axis of the common carotid artery (CCA) the CCA-ICA angle is measured between the CCA midaxis and the midaxis of the stenotic ICA segment. Maximal extensions of ICA tortuosities perpendicular to the course of the CCA axis are defined as ICA offset. The measurements were applied to DSA images of 224 carotid stenoses to evaluate variation and correlation between the two parameters. Comparative pre- and post-stent evaluation was performed in two series of 55 and 31 carotid stenoses treated with Wallstents and in a historic control group of 35 stenoses treated with Strecker stents. Straight course of the ICA was associated with low angle and low offset values, whereas tortuous course of the ICA showed larger angle and offset. A moderate linear correlation between the two parameters was found. Corresponding to a straightening of the stented segment, Wallstents reduced mean angle and offset values significantly. In five cases of the second series of Wallstents, transferrals of curves above the distal stent end associated with kinks were observed, and offset remained constant or increased. Strecker stent implantation caused no significant changes of bifurcational geometry. The proposed parameters corresponded to visual aspects of ICA tortuosity and detected reconstructive effects of self-expanding Wallstents on the ICA course. The measurement system may provide a basis for geometric evaluation of different stent types or implantation concepts with the aim: to optimize anatomic recanalization results in tortuous high angle-high offset bifurcations. (orig.)

  16. Technical feasibility of the implantation of a monorail stent system into the renal arteries without pre-dilatation

    International Nuclear Information System (INIS)

    Neumann, C.; Dorffner, R.; Gschwendtner, M.; Karnel, F.; Mair, J.; Dorffner, G.

    2005-01-01

    Purpose: to evaluate the technical feasibility of the implantation of the monorail RX Herculink trademark system into the renal arteries without pre-dilatation. Materials and methods: forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink trademark stent. The mean grade of the stenosis was 83.8%, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). Results: in 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30% were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 ± 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 ± 0.0. Conclusion: implantation of the RX Herculink trademark stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies. (orig.)

  17. Coronary Stents in Diabetic Patients: State of the Knowledge.

    Science.gov (United States)

    Codner, Pablo; Gurm, Hitinder Singh; Motivala, Apurva

    2017-04-01

    This review article aims to summarize the findings of the most relevant research that compared the use of paclitaxel vs. "limus" based drug eluting stent (DES) in diabetic patients and to define the current state of knowledge with new stent technologies in this patient population. Since drug eluting stents (DES) were introduced, it has been of great interest to establish whether paclitaxel or sirolimus eluting stents have the same safety and efficacy features for patients with coronary artery disease. The answer to this question is particularly relevant for diabetic patients. Several randomized trials, registry-based studies, and meta-analyses have assessed the performance of these different DES in diabetic patients. The most recently published data favors limus over paclitaxel DES in diabetic patients, but most of these studies compared first vs. second generation DES with the inherent caveats of comparing different platforms, alloys, and drug delivery vehicles. In this literature review, we found that there is robust evidence favoring the use of DES over bare metal stents in diabetic patients with coronary artery disease. We also found that the current state of knowledge is that the everolimus eluting stents have better safety and efficacy than paclitaxel eluting stents in diabetic patients and hence should be the preferred choice. New revascularization strategies including bio-absorbable scaffolds, polymer free stents, and bio-degradable polymers are being studied in diabetic patients with encouraging results.

  18. The Impact of Post-Procedural Asymmetry, Expansion, and Eccentricity of Bioresorbable Everolimus-Eluting Scaffold and Metallic Everolimus-Eluting Stent on Clinical Outcomes in the ABSORB II Trial.

    Science.gov (United States)

    Suwannasom, Pannipa; Sotomi, Yohei; Ishibashi, Yuki; Cavalcante, Rafael; Albuquerque, Felipe N; Macaya, Carlos; Ormiston, John A; Hill, Jonathan; Lang, Irene M; Egred, Mohaned; Fajadet, Jean; Lesiak, Maciej; Tijssen, Jan G; Wykrzykowska, Joanna J; de Winter, Robbert J; Chevalier, Bernard; Serruys, Patrick W; Onuma, Yoshinobu

    2016-06-27

    The study sought to investigate the relationship between post-procedural asymmetry, expansion, and eccentricity indices of metallic everolimus-eluting stent (EES) and bioresorbable vascular scaffold (BVS) and their respective impact on clinical events at 1-year follow-up. Mechanical properties of a fully BVS are inherently different from those of permanent metallic stent. The ABSORB II (A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions) trial compared the BVS and metallic EES in the treatment of a de novo coronary artery stenosis. Protocol-mandated intravascular ultrasound imaging was performed pre- and post-procedure in 470 patients (162 metallic EES and 308 BVS). Asymmetry index (AI) was calculated per lesion as: (1 - minimum scaffold/stent diameter/maximum scaffold/stent diameter). Expansion index and optimal scaffold/stent expansion followed the definition of the MUSIC (Multicenter Ultrasound Stenting in Coronaries) study. Eccentricity index (EI) was calculated as the ratio of minimum and maximum scaffold/stent diameter per cross section. The incidence of device-oriented composite endpoint (DoCE) was collected. Post-procedure, the metallic EES group was more symmetric and concentric than the BVS group. Only 8.0% of the BVS arm and 20.0% of the metallic EES arm achieved optimal scaffold/stent expansion (p 0.30 is an independent predictor of DoCE (hazard ratio: 3.43; 95% confidence interval: 1.08 to 10.92; p = 0.037). BVS implantation is more frequently associated with post-procedural asymmetric and eccentric morphology compared to metallic EES. Post-procedural devices asymmetry were independently associated with DoCE following percutaneous coronary intervention. However, this approach should be viewed as hypothesis generating due to low event rates. (ABSORB II Randomized Controlled Trial [ABSORB II]; NCT01425281). Copyright © 2016 American

  19. Development of radiolabelled compound using reactor producted RI - Evaluation of Ho-166 endovascular therapy to prevent restenosis after PTCA or stenting for occlusive coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Hee; Choi, Byung Il; Kim, Han Soo [Ajou University, Suwon (Korea)

    2000-04-01

    Occlusive coronary artery disease is managed successfully by percutaneous transfemoral coronary angioplasty (PTCA) or stenting with 95% success rate. However, restenosis after PTCA is not uncommon and the reported incidence of reocclusion is about 30 {approx} 40%. Therefore, the objective of the research was to develop endovascular brachytherapy using liquid form of Ho-166 in order to inhibit neointimal hyperplasia responsible for restenosis following PTCA or stenting. Our research was carried out in 3 stages: First stage - The effectiveness of radiation was confirmed by using animal model. Following over-sized balloon injury to rat carotid artery and porcine coronary artery, various external radiation doses were delivered. Second stage - For radiation dose distribution within the coronary artery and its surrounding tissues, Gafchromic film was used. In vitro dose distribution of Ho-166 utilizing water phantom and Gafchromic film was measured. Third stage - None uniform dose distribution from Ho-166 within the balloon caused by small air bubbles was eliminated by negative suction method. More accurate dose distribution was also possible using newly developed micrometer by our physicist. Limited number of human trial was performed without adverse effect. 40 refs. (Author)

  20. Drug-Coated Balloon Angioplasty: A Novel Treatment for Pulmonary Artery In-Stent Stenosis in a Patient with Williams Syndrome.

    Science.gov (United States)

    Cohen, Jennifer L; Glickstein, Julie S; Crystal, Matthew A

    2017-12-01

    A 20-month-old boy with Williams syndrome had undergone multiple surgical and catheter-based interventions for resistant peripheral pulmonary arterial stenoses with eventual bilateral stent placement and conventional balloon angioplasty. He persistently developed suprasystemic right ventricular (RV) pressure. Angioplasty with a drug-coated balloon (DCB) was performed for in-stent restenosis and to remodel his distal pulmonary vessels bilaterally. This resulted in immediate improvement in the in-stent stenosis and resultant decrease in RV pressure. Follow-up catheterization two months later continued to show long-lasting improvement in the in-stent stenosis. We hypothesize that the anti-proliferative effects of DCBs may be of benefit in the arteriopathy associated with Williams syndrome. We report this as a novel use of a DCB in the pulmonary arterial circulation in a patient with Williams syndrome.

  1. Bioresorbable Scaffold for Treatment of Coronary Artery Lesions: Intravascular Ultrasound Results From the ABSORB Japan Trial.

    Science.gov (United States)

    Okada, Kozo; Honda, Yasuhiro; Kitahara, Hideki; Otagiri, Kyuhachi; Tanaka, Shigemitsu; Hollak, M Brooke; Yock, Paul G; Popma, Jeffrey J; Kusano, Hajime; Cheong, Wai-Fung; Sudhir, Krishnankutty; Fitzgerald, Peter J; Kimura, Takeshi

    2018-04-09

    The aim of this study was to characterize post-procedural intravascular ultrasound (IVUS) findings in the ABSORB Japan trial, specifically stratified by the size of target coronary arteries. Despite overall noninferiority confirmed in recent randomized trials comparing bioresorbable vascular scaffolds (BVS) (Absorb BVS) and cobalt-chromium everolimus-eluting metallic stents (CoCr-EES), higher event rates of Absorb BVS have been reported with suboptimal deployment, especially in small coronary arteries. In the ABSORB Japan trial, 150 patients (2:1 randomization) were scheduled in the IVUS cohort. Small vessel was defined as mean reference lumen diameter strategy, possibly different between polymeric and metallic devices, needs to be established for bioresorbable scaffold technology. (AVJ-301 Clinical Trial: A Clinical Evaluation of AVJ-301 Absorb™ BVS) in Japanese Population [ABSORB JAPAN]; NCT01844284). Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin

    Energy Technology Data Exchange (ETDEWEB)

    Pecoraro, Felice, E-mail: felicepecoraro@libero.it; Sabatino, Ermanno R.; Dinoto, Ettore; Rosa, Giuliana La; Corte, Giuseppe; Bajardi, Guido [University of Palermo, Vascular Surgery Unit (Italy)

    2015-10-15

    A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conventional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobactam. Patient management consisted of fistula drainage, systemic antibiotic therapy, and daily wound dressing. At 1-month follow-up, the wound was closed. To our knowledge, this is the first case of this type of stent-graft complication presenting with external expulsion.

  3. Coronary Artery Bypass Surgery Versus Drug-Eluting Stent Implantation for Left Main or Multivessel Coronary Artery Disease A Meta-Analysis of Individual Patient Data

    NARCIS (Netherlands)

    Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W.; Park, Seung-Jung

    2016-01-01

    OBJECTIVES The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD).

  4. Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, Claus Christian, E-mail: Claus.christian.pieper@ukb.uni-bonn.de; Meyer, Carsten, E-mail: Carsten.Meyer@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany); Rudolph, Jens, E-mail: jens.rudolph@ukb.uni-bonn.de; Verrel, Frauke, E-mail: frauke.verrel@ukb.uni-bonn.de [University of Bonn, Department of Surgery (Germany); Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de; Wilhelm, Kai E., E-mail: kai.wilhelm@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany)

    2013-08-01

    PurposeThis study was designed to evaluate retrospectively the results of complex iliac artery aneurysm (IAA) exclusion using the Cardiatis-Multilayer-Stent.MethodsBetween October 2010 and August 2012, ten IAAs were treated in eight males (mean age 75 (59-91) years) using the Multilayer Stent. All IAA exceeded a diameter of 3 cm or were symptomatic. Follow-up (FU) examinations included CT or MR angiography, sonography, and clinical assessment up to 2 years.ResultsPrimary stent placement was technically successful in eight of ten cases. In two cases, severe stent retraction during deployment necessitated placement of an additional stent. Immediately after stent placement, a marked reduction of flow within the sac was observed in all cases (peri-interventional mortality 0 %). During FU, there were two thrombotic stent occlusions, making reintervention necessary (primary patency rate 80 %, secondary patency 100 %). Four IAA were completely occluded at FU, whereas the original vessel and covered branches (n = 8) were patent. In four IAA, there was still residual perfusion. In one patient, IAA diameter decreased slightly, while it remained constant in seven (mean imaging FU 195 (range 1-695) days). There were no adverse events on clinical FU (mean FU 467 (range 101-695) days).ConclusionsOther studies showed the Cardiatis-Multilayer-Stent to be a technically relatively simple treatment option for complex IAA with inadequate landing zones, especially in patients with multiple comorbidities to avoid ipsilateral IIA obstruction. However, in our series complication rate was high. Incomplete sac exclusion, stent-shortening, and thrombotic occlusion can complicate treatment, making meticulous patient selection necessary. Close imaging surveillance is mandatory especially in the early postinterventional period.

  5. Direct stent puncture technique for intraluminal stent recanalization in the superficial femoral and popliteal arteries in-stent occlusion: Outcomes from a prospective clinical analysis of diabetics with critical limb ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Palena, Luis Mariano, E-mail: marianopalena@hotmail.com; Manzi, Marco

    2013-07-15

    Purpose: To evaluate the efficacy and safety of “Direct Stent Puncture” technique for intraluminal stent recanalization in the femoro-popliteal segments. Methods and Materials: A cohort of diabetics who had symptomatic in-stent occlusion of the superficial femoral or popliteal arteries underwent endovascular recanalization. After antegrade failure, direct stent puncture technique was performed. The primary end-point was to efficacy assessment, intended as technical success and clinical improvement. The secondary end-point was safety assessment, intended as free of complication rate. Results: Fifty-four patients (37 men; 73.6 ± 8.5 years) underwent direct stent puncture technique, after several unsuccessful antegrade attempts to cross the occluded stent. Technical success for intraluminal stent recanalization was achieved in 53/54 (98.2%) of cases and failed in 1/54 (1.8%). Clinical improvement was obtained in 51/54 (94.4%) of cases, with regression of the clinical symptoms and improvement of the TcPO{sub 2}, from 3 ± 18 mmHg to 43 ± 11 mmHg after 15 days (p < 0.001). Free of complications rate was 92.5%. In 2/54 (3.7%) of cases distal embolization occurred, in 1/54 (1.9%) case a sudden vessel thrombosis was diagnosed after 12 hours and in 1/54 (1.9%) case hematoma at the stent puncture site was observed. Conclusions: Direct Stent Puncture technique is an efficacy and safety option for intraluminal stent recanalization in the femoro-popliteal segment in-stent occlusion.

  6. The Bolton Treovance abdominal stent-graft: European clinical trial design.

    Science.gov (United States)

    Chiesa, R; Riambau, V; Coppi, G; Zipfel, B; Llagostera, S; Marone, E M; Kahlberg, A

    2012-10-01

    Endovascular aortic repair (EVAR) has emerged as a promising, less invasive alternative to conventional open surgery for the treatment of infrarenal abdominal aortic aneurysms (AAAs). In the last 20 years, the application rate of EVAR and its clinical results have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary re-interventions. The Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain) is a new-generation endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. In particular, it is provided with some innovative features as a double layer of proximal barbs (suprarenal and infrarenal) for supplemental fixation, dull barbs between modules to avoid potential leg disconnections, detachable outer sheath provided with a new-design hemostatic valve, and a double improved mechanism (slow motion and "pin and pull") for precise stent-graft deployment. A European prospective, non-randomized, multi-institutional, "first-in-human" trial (the ADVANCE trial) was conducted from March to December 2011 to assess the safety and performance of the Treovance stent-graft system before commercialization. Thirty patients with anatomically suitable non-ruptured AAAs were enrolled at five clinical sites in Italy, Spain, and Germany. EVAR was completed successfully in all patients. The stent-graft was delivered and deployed safely even in heavily angulated or calcified anatomies. No 30-day device-related complications nor deaths were observed. Preliminary experience with the Treovance abdominal stent-graft within the ADVANCE trial was satisfactory with regard to technical success and perioperative clinical results. Follow-up data are needed to assess mid- and long-term clinical outcomes, along with durability of this new-generation endovascular device.

  7. Balloon Tamponade Treatment of a Stent-graft Related Rupture with a Splenic Artery Pseudoaneurysm: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, See Hyung; Kim, Young Hwan [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stentgraft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency

  8. Endeavour zotarolimus-eluting stent reduces stent thrombosis and improves clinical outcomes compared with cypher sirolimus-eluting stent : 4-year results of the PROTECT randomized trial

    NARCIS (Netherlands)

    Wijns, William; Steg, Ph. Gabriel; Mauri, Laura; Kurowski, Volkhard; Parikh, Keyur; Gao, Runlin; Bode, Christoph; Greenwood, John P.; Lipsic, Erik; Alamgir, Farqad; Rademaker-Havinga, Tessa; Boersma, Eric; Radke, Peter; van Leeuwen, Frank; Camenzind, Edoardo

    2014-01-01

    Aims To compare the long-term clinical safety between two drug-eluting stents with different healing characteristics in the Patient Related Outcomes with Endeavour (E-ZES) vs. Cypher (C-SES) Stenting Trial (PROTECT). At 3 years, there was no difference in the primary outcome of definite or probable

  9. Angioplasty or Stenting of Extra- and Intracranial Vertebral Artery Stenoses

    International Nuclear Information System (INIS)

    Hauth, Elke A.M.; Gissler, H. Martin; Drescher, Robert; Jansen, Christian; Jaeger, Horst J.; Mathias, Klaus D.

    2004-01-01

    Purpose: To determine the feasibility and safety of angioplasty or angioplasty and stenting of extra- and intracranial vertebral artery (VA) stenosis. Methods: In 16 consecutive patients (9 men, 7 women; mean age 61 years, range 49-74 years) 16 stenotic VAs were treated with angioplasty orangioplasty and stenting. Eleven stenoses were localized in V1 segment,1 stenosis in V2 segment and 4 stenoses in V4 segment of VA. Fourteen VA stenoses were symptomatic, 2 asymptomatic. The etiology of the stenoses was atherosclerotic in all cases. Results:Angioplasty was performed in 8 of 11 V1 and 2 of 4 V4 segments of the VA. In 3 of 11 V1 segments and 2 of 4 V4 segments of the VA we combined angioplasty with stenting. The procedures were successfully performed in 14 of 16 VAs (87%). Complications were asymptomatic vessel dissection resulting in vessel occlusion in 1 of 11 V1 segments and asymptomatic vessel dissection in 2 of 4 V4 segments of the VA. One patient died in the 24-hr period after the procedure because of subarachnoid hemorrhage as a complication following vessel perforation of the treated V4 segment. Conclusion: Angioplasty orangioplasty and stenting of extracranial VA stenoses can be performed with a high technical success rate and a low complication rate. In intracranial VA stenosis the procedure is technically feasible but complications can be life-threatening. The durability and procedural complication rates of primary stenting without using predilation in extra- and intracranial VA stenosis should be defined in the future

  10. Percutaneous common femoral artery interventions using angioplasty, atherectomy, and stenting.

    Science.gov (United States)

    Mehta, Manish; Zhou, Yi; Paty, Philip S K; Teymouri, Medhi; Jafree, Kamran; Bakhtawar, Humayun; Hnath, Jeffrey; Feustel, Paul

    2016-08-01

    This study evaluated the feasibility, safety, and effectiveness of endovascular interventions for common femoral artery (CFA) occlusive disease. Using a prospectively maintained multicenter database, we analyzed outcomes in 167 consecutive patients who underwent percutaneous CFA interventions for Rutherford class 3 to class 6 (R3-R6) disease. The standardized treatment approach included primary percutaneous transluminal angioplasty (PTA) only, atherectomy + PTA, and provisional stenting. Outcomes included technical failure rate, recurrence, complications, and major or minor amputation rate. Data were analyzed using multivariate regression analysis. During a 7-year period, 167 patients with R3 (n = 91 [54.5%]) and R4 to R6 (n = 76 [45.5%]) disease underwent CFA interventions that included PTA only (n = 114 [68.2%]), atherectomy ± PTA (n = 38 [22.8%]), and provisional stenting (n = 15 [9.0%]) for failed atherectomy ± PTA. Procedure-related complications included pseudoaneurysm (n = 1 [0.6%]), thrombosis (n = 1 [0.6%]), distal embolization (n = 1 [0.6%]), and death (R6, n = 1 [0.06%]). CFA restenosis was observed in 34 (20.4%) patents; these underwent further percutaneous (n = 18 [10.8%]) or surgical (n = 17 [10.2%]) revascularization that included CFA endarterectomy ± femoral distal bypass. Major or minor amputations were observed in none of the R3 patients and in only three (3.9%) and five (6.5%) of the R4 to R6 patients, respectively. Compared with the atherectomy + PTA group, patients in the PTA-only group had a significantly lower patency. Furthermore, during long-term mean follow-up of 42.5 months, the CFA provisional stent group had a 100% primary patency, which was significantly better than the primary patency in the CFA nonstent groups combined (77.0%; P = .0424). Data from this study to date would suggest that percutaneous CFA interventions in select patients are relatively safe and effective. In the long term, CFA stenting has

  11. Microfocal X-ray computed tomography post-processing operations for optimizing reconstruction volumes of stented arteries during 3D computational fluid dynamics modeling.

    Science.gov (United States)

    Ladisa, John F; Olson, Lars E; Ropella, Kristina M; Molthen, Robert C; Haworth, Steven T; Kersten, Judy R; Warltier, David C; Pagel, Paul S

    2005-08-01

    Restenosis caused by neointimal hyperplasia (NH) remains an important clinical problem after stent implantation. Restenosis varies with stent geometry, and idealized computational fluid dynamics (CFD) models have indicated that geometric properties of the implanted stent may differentially influence NH. However, 3D studies capturing the in vivo flow domain within stented vessels have not been conducted at a resolution sufficient to detect subtle alterations in vascular geometry caused by the stent and the subsequent temporal development of NH. We present the details and limitations of a series of post-processing operations used in conjunction with microfocal X-ray CT imaging and reconstruction to generate geometrically accurate flow domains within the localized region of a stent several weeks after implantation. Microfocal X-ray CT reconstruction volumes were subjected to an automated program to perform arterial thresholding, spatial orientation, and surface smoothing of stented and unstented rabbit iliac arteries several weeks after antegrade implantation. A transfer function was obtained for the current post-processing methodology containing reconstructed 16 mm stents implanted into rabbit iliac arteries for up to 21 days after implantation and resolved at circumferential and axial resolutions of 32 and 50 microm, respectively. The results indicate that the techniques presented are sufficient to resolve distributions of WSS with 80% accuracy in segments containing 16 surface perturbations over a 16 mm stented region. These methods will be used to test the hypothesis that reductions in normalized wall shear stress (WSS) and increases in the spatial disparity of WSS immediately after stent implantation may spatially correlate with the temporal development of NH within the stented region.

  12. European Registry of Carotid Artery Stenting: results from a prospective registry of eight high volume EUROPEAN institutions.

    Science.gov (United States)

    Stabile, Eugenio; Garg, Pallav; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitry; Werner, Martin; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Mauri, Laura; Rubino, Paolo

    2012-08-01

    Carotid endarterectomy (CEA) is the standard revascularization therapy to prevent stroke in patients with carotid artery disease. Carotid artery stenting (CAS) could be considered a potential alternative in patients at high surgical risk. Recent clinical trials have challenged this concept due a relatively high incidence of post-CAS adverse events, which occurred in low volume centers. The aim of this study was to evaluate the outcomes associated with neuroprotected CAS in selected high volume centers. From January 2007 to December 2007, 1,611 patients underwent neuroprotected CAS in eight European Centers. For each patients, clinical, procedural, and one month follow-up data from all patients have been collected. An independent clinical events committee adjudicated the events. Overall in hospital death was 0.06% (one patient), whereas in-hospital stroke was 0.49% (eight patients). Between hospital discharge and 30 days three additional patients died (0.18%) and 10 patients experienced a stroke (0.67%). Overall 30 days mortality was 0.24% (four patients) and stroke incidence 1.12% (18 patients). The 30 day stroke/death rate was 1.36%. CAS is a reasonable alternative to CEA to treat carotid artery atherosclerosis in well-experienced high volume centers. These data suggest that future prospective trials comparing CAS and CEA outcomes should include only centers highly experienced in both treatment modalities. Copyright © 2012 Wiley Periodicals, Inc.

  13. Very late stent thrombosis with second generation drug eluting stents compared to bare metal stents: Network meta-analysis of randomized primary percutaneous coronary intervention trials.

    Science.gov (United States)

    Philip, Femi; Stewart, Susan; Southard, Jeffrey A

    2016-07-01

    The relative safety of drug-eluting stents (DES) and bare-metal stents (BMS) in primary percutaneous coronary intervention (PPCI) in ST elevation myocardial infarction (STEMI) continues to be debated. The long-term clinical outcomes between second generation DES and BMS for primary percutaneous coronary intervention (PCI) using network meta-analysis were compared. Randomized controlled trials comparing stent types (first generation DES, second generation DES, or BMS) were considered for inclusion. A search strategy used Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion criteria, and sample characteristics were extracted. Network meta-analysis was used to pool direct (comparison of second generation DES to BMS) and indirect evidence (first generation DES with BMS and second generation DES) from the randomized trials. Twelve trials comparing all stents types including 9,673 patients randomly assigned to treatment groups were analyzed. Second generation DES was associated with significantly lower incidence of definite or probable ST (OR 0.59, 95% CI 0.39-0.89), MI (OR 0.59, 95% CI 0.39-0.89), and TVR at 3 years (OR 0.50: 95% CI 0.31-0.81) compared with BMS. In addition, there was a significantly lower incidence of MACE with second generation DES versus BMS (OR 0.54, 95% CI 0.34-0.74) at 3 years. These were driven by a higher rate of TVR, MI and stent thrombosis in the BMS group at 3 years. There was a non-significant reduction in the overall and cardiac mortality [OR 0.83, 95% CI (0.60-1.14), OR 0.88, 95% CI (0.6-1.28)] with the use of second generation DES versus BMS at 3 years. Network meta-analysis of randomized trials of primary PCI demonstrated lower incidence of MACE, MI, TVR, and stent thrombosis with second generation DES compared with BMS. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Genous endothelial progenitor cell-capturing stent system: a novel stent technology

    NARCIS (Netherlands)

    Klomp, Margo; Beijk, Marcel A. M.; de Winter, Robbert J.

    2009-01-01

    Drug-eluting stents have been demonstrated to significantly reduce clinical and angiographic restenosis in patients with coronary artery disease compared with bare-metal stents. Intuitively, however, a prohealing approach for the prevention of in-stent restenosis by promoting accelerated

  15. Paclitaxel-eluting stents versus everolimus-eluting coronary stents in a diabetic population: two-year follow-up of the TUXEDO-India trial.

    Science.gov (United States)

    Kaul, Upendra; Bhagwat, Ajit; Pinto, Brian; Goel, Praveen K; Jagtap, Prashant; Sathe, Shireesh; Wander, Gurpreet S; Arambam, Priyadarshini; Bangalore, Sripal

    2017-11-20

    The aim of this study was to report whether the superiority of the everolimus-eluting stent (EES) vs. the paclitaxel-eluting stent (PES) at one-year follow-up in the Taxus Element versus Xience Prime in a Diabetic Population (TUXEDO)-India trial was sustained at longer-term follow-up. One thousand eight hundred and thirty (1,830) patients with diabetes mellitus and coronary artery disease were randomised to EES vs. PES. Follow-up data up to two years were available in 1,701 (92.9%) patients. The primary endpoint was target vessel failure (TVF), defined as the composite of cardiac death, target vessel myocardial infarction (TV-MI), or ischaemia-driven target vessel revascularisation (TVR). Treatment with EES had a lower two-year rate of TVF (4.3% vs. 6.6%, p=0.03). Of the secondary endpoints, EES significantly reduced any MI (1.6% vs. 3.5%, p=0.01), TV-MI (0.7% vs. 3.1%, p=0.0001), ST (0.4% vs. 2.2%, p=0.001), cardiac death or target vessel MI (2.9% vs. 4.8%, p=0.04) and TLR (1.9% vs. 3.7%, p=0.02), compared with PES. Between one year and two years, no significant differences in the clinical outcomes were observed (pinteraction >0.05). In this adequately powered trial, the benefits of EES vs. PES in a diabetic population seen at one year were maintained at two years.

  16. Short vs prolonged dual antiplatelet treatment upon endovascular stenting of peripheral arteries

    Directory of Open Access Journals (Sweden)

    Kronlage M

    2017-10-01

    Full Text Available Mariya Kronlage,1 Maximilian Wassmann,1 Britta Vogel,1 Oliver J Müller,1 Erwin Blessing,2 Hugo Katus,1,3 Christian Erbel1 1Department of Cardiology, Angiology and Pneumology, University Hospital Heidelberg, Heidelberg, 2SRH Klinikum Karlsbad Langensteinbach, Karlsbad, 3DZHK German Center for Cardiovascular Research, Partner Site Heidelberg/Mannheim, Mannheim, Germany Introduction: Peripheral artery disease (PAD is a highly prevalent disorder with a substantial economical burden. Dual antiplatelet treatment (DAPT upon endovascular stenting to prevent acute thrombotic reocclusions is an universally accepted practice for postinterventional management of PAD patients. However, the optimal period of time for DAPT upon endovascular stenting is not known.Methods: In the current nonrandomized, retrospective monocentric study, we evaluated the duration of DAPT upon endovascular stenting. A total of 261 endovascular SFA and iliac stenting procedures were performed on 214 patients and these patients were subdivided into a short (4–6 weeks or a prolonged (8–12 weeks DAPT regime group. More than 65% of the patients included were male, approximately 35% were diabetic, and 61% had a history of smoking. Of all the patients, 90% exhibited a Rutherford stage 2–3, and approximately half of the patients had a moderate-to-severe calcified target lesion with a length of >13 cm. Major safety end points were defined as any bleeding, compartment syndrome, and ischemic events. In addition to this, patency, all-cause mortality, as well as amputation were followed up over a period of 12 months upon intervention.Results: Twelve months after endovascular stenting, primary patency in our cohort was comparable between the groups (83.94% short vs 79.8% long DAPT, P>0.05. Major bleeding occurred in 18 cases without any difference between the groups (P>0.05. In addition, during the 12-month follow-up, 6 (3.4% patients in the short and 3 (3.5% in the prolonged DAPT regime

  17. Comparison of paclitaxel- and sirolimus-eluting stents in everyday clinical practice: the SORT OUT II randomized trial

    DEFF Research Database (Denmark)

    Galløe, Anders M; Thuesen, Leif; Kelbaek, Henning

    2008-01-01

    Approval of drug-eluting coronary stents was based on results of relatively small trials of selected patients; however, in routine practice, stents are used in a broader spectrum of patients.......Approval of drug-eluting coronary stents was based on results of relatively small trials of selected patients; however, in routine practice, stents are used in a broader spectrum of patients....

  18. Thoracic aortic stent-graft placement combined with left subclavian artery 'chimney operation': therapeutic analysis of 15 cases with insufficient proximal anchor area

    International Nuclear Information System (INIS)

    Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi

    2012-01-01

    Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with

  19. Drug-eluting stent thrombosis: results from the multicenter Spanish registry ESTROFA (Estudio ESpañol sobre TROmbosis de stents FArmacoactivos).

    Science.gov (United States)

    de la Torre-Hernández, José M; Alfonso, Fernando; Hernández, Felipe; Elizaga, Jaime; Sanmartin, Marcelo; Pinar, Eduardo; Lozano, Iñigo; Vazquez, Jose M; Botas, Javier; Perez de Prado, Armando; Hernández, Jose M; Sanchis, Juan; Nodar, Juan M Ruiz; Gomez-Jaume, Alfredo; Larman, Mariano; Diarte, Jose A; Rodríguez-Collado, Javier; Rumoroso, Jose R; Lopez-Minguez, Jose R; Mauri, Josepa

    2008-03-11

    This study sought to assess the incidence, predictors, and outcome of drug-eluting stent(DES) thrombosis in real-world clinical practice. The DES thromboses in randomized trials could not be comparable to those observed in clinical practice, frequently including off-label indications. We designed a large-scale, nonindustry-linked multicentered registry, with 20 centers in Spain. The participant centers provided follow-up data for their patients treated with DES, reporting a detailed standardized form in the event of any angiography-documented DES-associated thrombosis occurring. Of 23,500 patients treated with DES, definite stent thrombosis(ST) developed in 301: 24 acute, 125 subacute, and 152 late. Of the late, 62 occurred >1 year(very late ST). The cumulative incidence was 2% at 3 years. Antiplatelet treatment had been discontinued in 95 cases(31.6%). No differences in incidences were found among stent types. Independent predictors for subacute ST analyzed in a subgroup of 14,120 cases were diabetes, renal failure, acute coronary syndrome, ST-segment elevation myocardial infarction, stent length, and left anterior descending artery stenting, and for late ST were ST-segment elevation myocardial infarction, stenting in left anterior descending artery, and stent length. Mortality at 1-year follow-up was 16% and ST recurrence 4.6%. Older age, left ventricular ejection fraction <45%, nonrestoration of Thrombolysis In Myocardial Infarction flow grade 3, and additional stenting were independent predictors for mortality. The cumulative incidence of ST after DES implantation was 2% at 3 years. No differences were found among stent types. Patient profiles differed between early and late ST. Short-term prognosis is poor, especially when restoration of normal flow fails.

  20. [Changes of brain function and cognitive function after carotid artery stenting].

    Science.gov (United States)

    Lu, Z X; Deng, G; Wei, H L; Zhao, G F; Wen, L Z; Chen, X

    2017-10-24

    Objective: To investigate the effect of carotid artery stenting(CAS) on cognitive function and brain function based on changes of a battery of neuropsychological tests and magnetic resonance imaging. Methods: Thirty-three patients were included with 17 in the stent-placement group and 16 in the control group (receiving medical treatment), among whom, the unilateral or bilateral severe internal carotid artery stenosis was confirmed by cerebral vascular angiography in the department of Interventional Radiology and Vascular Surgery of Zhongda Hospital Southeast University from June 2015 to September 2016.Neuropsychological tests and rest-state blood oxygenation level dependent fMRI were performed at the baseline and six months follow-up.The baseline characteristics and follow-up changes were compared in each group. Results: The overall cognitive function of the stent-placement group was statistically significantly improved ( P function, memory, attention and other aspects.The value of amplitude of low-frequency fluctuation(ALFF) showed statistically significant increase ( P left prefrontal cortex ( t =5.861 3, P left superior parietal lobe( t =5.601 2, P left retrosplenial cingulate cortex( t =-5.590 4, P left insular cortex ( t =-6.340 8, P right insular cortex ( t =-8.129 9, P left dorsal anterior cingulate cortex ( t =-5.584 8, P 0.05, Alphasim correction)between baseline and follow-up results in control group.Besides, the ALFF changes of the left insular cortex ( r =-0.591, P =0.033) and bilateral motor cortical area ( r =-0.659, P =0.014) were negatively correlated with auditory verb learning test (AVLT) score changes.The ALFF change of bilateral motor cortical area was negatively correlated with the AVLT-delay score change ( r =-0.588, P =0.034). And the ALFF change on right insular cortex and the frontal assessment battery (FAB) score change was positively correlated ( r =0.638, P =0.025). Conclusions: The overall cognitive function of patients with carotid

  1. A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary Arteries IV study

    Directory of Open Access Journals (Sweden)

    Teeuwen Koen

    2012-12-01

    Full Text Available Abstract Background Percutaneous recanalization of total coronary occlusion (TCO was historically hampered by high rates of restenosis and reocclusions. The PRISON II trial demonstrated a significant restenosis reduction in patients treated with sirolimus-eluting stents compared with bare metal stents for TCO. Similar reductions in restenosis were observed with the second-generation zotarolimus-eluting stent and everolimus-eluting stent. Despite favorable anti-restenotic efficacy, safety concerns evolved after identifying an increased rate of very late stent thrombosis (VLST with drug-eluting stents (DES for the treatment of TCO. Late malapposition caused by hypersensitivity reactions and chronic inflammation was suggested as a probable cause of these VLST. New DES with bioresorbable polymer coatings were developed to address these safety concerns. No randomized trials have evaluated the efficacy and safety of the new-generation DES with bioresorbable polymers in patients treated for TCO. Methods/Design The prospective, randomized, single-blinded, multicenter, non-inferiority PRISON IV trial was designed to evaluate the safety, efficacy, and angiographic outcome of hybrid sirolimus-eluting stents with bioresorbable polymers (Orsiro; Biotronik, Berlin, Germany compared with everolimus-eluting stents with durable polymers (Xience Prime/Xpedition; Abbott Vascular, Santa Clara, CA, USA in patients with successfully recanalized TCOs. In total, 330 patients have been randomly allocated to each treatment arm. Patients are eligible with estimated duration of TCO ≥4 weeks with evidence of ischemia in the supply area of the TCO. The primary endpoint is in-segment late luminal loss at 9-month follow-up angiography. Secondary angiographic endpoints include in-stent late luminal loss, minimal luminal diameter, percentage of diameter stenosis, in-stent and in-segment binary restenosis and reocclusions at 9-month follow-up. Additionally, optical coherence

  2. Risk of Stroke or Death Is Associated With the Timing of Carotid Artery Stenting for Symptomatic Carotid Stenosis: A Secondary Data Analysis of the German Statutory Quality Assurance Database.

    Science.gov (United States)

    Tsantilas, Pavlos; Kuehnl, Andreas; Kallmayer, Michael; Knappich, Christoph; Schmid, Sofie; Breitkreuz, Thorben; Zimmermann, Alexander; Eckstein, Hans-Henning

    2018-03-27

    Subgroup analyses from randomized trials indicate that the time interval between the neurologic index event and carotid artery stenting is associated with periprocedural stroke and death rates in patients with symptomatic carotid stenosis. The aim of this article is to analyze whether this observation holds true under routine conditions in Germany. Secondary data analysis was done on 4717 elective carotid artery stenting procedures that were performed for symptomatic carotid stenosis. The patient cohort was divided into 4 groups according to the time interval between the index event and intervention (group I 0-2, II 3-7, III 8-14, and IV 15-180 days). Primary outcome was any in-hospital stroke or death. For risk-adjusted analyses, a multilevel multivariable regression model was used. The in-hospital stroke or death rate was 3.7% in total and 6.0%, 4.4%, 2.4%, and 3.0% in groups I, II, III, and IV, respectively. Adjusted analysis showed a decreased risk for any stroke or death in group III, a decreased risk for any major stroke or death in groups III and IV, and a decreased risk for any death in groups II and III compared to the reference group I. A short time interval between the neurologic index event and carotid artery stenting of up to 7 days is associated with an increased risk for stroke or death under routine conditions in Germany. Although results cannot prove causal relationships, carotid artery stenting may be accompanied by an increased risk of stroke or death during the early period after the index event. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  3. Endovascular stents: a review of their use in peripheral arterial disease.

    Science.gov (United States)

    Kudagi, Vinod S; White, Christopher J

    2013-06-01

    Technological advances in the past decade have shifted revascularization strategies from traditional open surgical approaches toward lower-morbidity percutaneous endovascular treatments for patients with lower extremity peripheral arterial disease (PAD). The continuing advances in stent design, more than any other advances, have fueled the growth of catheter-based procedures by improving the safety, durability, and predictability of percutaneous revascularization. Although the 2007 TransAtlantic Inter-Society Consensus (TASC) guidelines recommend endovascular therapy for type A and B aortoiliac and femoropopliteal lesions, recent developments in stent technology and increased experience of interventionists have suggested that a strategy of endovascular therapy first is appropriate in experienced hands for TASC type D lesions. The role of endovascular interventions is also expanding in the treatment of limb-threatening ischemia.

  4. A suggested training programme for carotid artery stenting (CAS)

    International Nuclear Information System (INIS)

    Gaines, Peter; Nicholson, Tony

    2006-01-01

    Carotid artery stenting as an alternative to traditional carotid endartrectomy is becoming increasingly important in the treatment of transient ischemic attack and stroke. Physicians from several different medical disciplines are interested in treating appropriate patients by this method. Patients are entitled to know what training and experience the surgeon or clinician has before giving consent. This should involve endovascular experience in all systems and experience and knowledge of cerebral angiography and intervention. A multidisciplinary approach and reporting of adverse events is vital for patient safety

  5. Cerebral ischemia after filter-protected carotid artery stenting is common and cannot be predicted by the presence of substantial amount of debris captured by the filter device.

    Science.gov (United States)

    Maleux, G; Demaerel, P; Verbeken, E; Daenens, K; Heye, S; Van Sonhoven, F; Nevelsteen, A; Wilms, G

    2006-10-01

    Protected carotid artery stent placement is currently under clinical evaluation as a potential alternative to carotid endarterectomy. The current study was undertaken to determine the incidence of new ischemic lesions found on diffusion-weighted MR imaging (DWI) in nonselected patients after protected carotid artery stent placement using a filter device and to determine the potential relationship between these new ischemic lesions and the presence or absence of a clear amount of debris captured by the neuroprotection filter device. A nonrandomized cohort of 52 patients (40 men, 12 women) presenting with carotid occlusive disease underwent protected carotid artery stent placement using a filter device. DWI obtained 1 day before stent placement was compared with that obtained 1 day after stent placement. In addition, the macroscopic and microscopic analysis of debris captured by the filter device during the carotid stent placement procedure was assessed. Neuroprotected carotid stent placement was technically successful in all 53 procedures but was complicated by a transient ischemic attack in 3 patients (5.6%). In 22 patients (41.5%), new ischemic lesions were found on DWI, and in 21 filter devices (39.6%), a substantial amount of atheromatous plaque and/or fibrin was found. No clear relationship between the presence of debris captured by the filter device and new lesions detected by DWI was found (P = .087; odds ratio 3.067). Neuroprotected carotid artery stent placement will not avoid silent cerebral ischemia. Systematic microscopic analysis of debris captured by the filter device has no predictive value for potential cerebral ischemia after carotid artery stent placement.

  6. Recurrence of Subacute Stent Thrombosis and In-Stent Restenosis during Five Months after Stent Implantation in the LAD. A Case Report.

    OpenAIRE

    島田, 弘英; 大和, 眞史; 櫻井, 俊平; 疋田, 博之; 池田, 修一

    2001-01-01

    A coronary stent was deployed in the left anterior descending artery of an 82-year-old woman with unstable angina.Recurrence of subacute stent thrombosis and in-stent restenosis occurred frequently during the five months after initial stent implantation.Balloon angioplasty and cutting balloon angioplasty failed to prevent these complications,but they ceased after re-stenting in the initial stent.In this case,tissue protrusion through the stent strut, deformation of the coil stent and inadequa...

  7. Pseudoaneurysm of the Internal Carotid Artery: Treatment with a Covered Stent

    International Nuclear Information System (INIS)

    Scavee, Vincent; Wispelaere, Jean-Francois de; Mormont, Eric; Coulier, Bruno; Trigaux, Jean-Paul; Schoevaerdts, Jean-Claude

    2001-01-01

    Dissection of the cervical segment of the internal carotid artery may occur spontaneously or after trauma. We report the management of a 53-year-old right-handed man with progressive dizziness and neck pain 6 weeks after a motor vehicle collision. The clinical and neurologic examinations were normal. The CT scan led to the diagnosis of a pseudoaneurysm of the right internal carotid artery near the skull base. We successfully treated this post-traumatic lesion with a covered stent. The patient underwent the endovascular procedure under general anesthesia and transcranial Doppler monitoring. No neurologic event was observed. Obliteration of the pseudoaneurysm with preservation of the carotid artery was achieved. The patient was discharged from the hospital 72 hr later with no complications. Clinical and imaging follow-up at 6 months was unremarkable

  8. The impact of renal artery stent revascularization on blood pressure: 1-year follow-up of 110 cases

    International Nuclear Information System (INIS)

    Wang Chao; Zou Yinghua; Yang Min; Wang Jian; Tong Xiaoqiang; Song Li

    2007-01-01

    Objective: To investigate the effect of renal artery revascularization through renal artery stenting(PTRAS)on blood pressure in patients with renal artery stenosis. Methods: During April 2000 through May 2005 110 cases of renal artery stenosis received PTRAS and followed up for at least 1 year with blood pressure measurements pre-and 1 year post-PTRAS. Results: The technical success rate was 100% for all 110 cases. The renal artery stenosis were decreased from 60%-100% before PTRAS to 0%-15% after the stent placement. There was significant difference between blood pressure pre-and 1 year post PTRAS. Systolic pressures decreased from(153 ± 32) mmHg to(131 ± 27) mmHg and diastolic pressures from(87 ± 19) mmHg to(75 ± 19) mmHg. The administration of antihypertensive diugs reduced from(2.6 ± 0.9 ) sorts to(1.9 ± 0.9) sorts. Conclusions: PTRAS revascularization is an effective procedure for blood pressure control in renal vascular hypertension during one year follow up. (authors)

  9. TIDES-ACS Trial: comparison of titanium-nitride-oxide coated bio-active-stent to the drug (everolimus)-eluting stent in acute coronary syndrome. Study design and objectives.

    Science.gov (United States)

    Colkesen, E B; Eefting, F D; Rensing, B J; Suttorp, M J; Ten Berg, J M; Karjalainen, P P; Van Der Heyden, J A

    2015-02-01

    Drug-eluting stents (DES), delivering antiproliferative drugs from a durable polymer, have shown to reduce in-stent restenosis after percutaneous coronary intervention (PCI) compared to bare-metal stents (BMS). However, they have been associated with a hypersensitivity reaction, delayed healing, and incomplete endothelialization, which may contribute to an increased risk of late stent thrombosis. Consequently, a prolonged duration of dual antiplatelet therapy (DAPT) is needed, with an increased risk of bleeding complication. A number of stent technologies are being developed in an attempt to modify late thrombotic events and DAPT duration. The Optimax™ stent is such a novel, next generation bioactive stent (BAS), in which a thicker layer of titanium-nitride-oxide coating is inserted over the stent struts. The rationale of this is to obtain more efficient and rapid vascular healing at the site of the stent implantation. The aim of TIDES-ACS Trial is to compare clinical outcome in patients presenting with ACS, treated with PCI using Optimax-BAS versus Synergy™-EES. Second objective is to explore whether the Optimax™-BAS use is superior compared with Synergy™-EES use with respect of hard end points (cardiac death, myocardial infarction [MI] and major bleeding). A prospective, randomized, multicenter trial (ClinicalTrials.gov Identifier: NCT02049229), will be conducted in interventional centres in Finland (six centres), France (five centres) and Holland (two centres), including a total of 1800 patients.

  10. Comparison of coronary-artery bypass surgery and stenting for the treatment of multivessel disease

    NARCIS (Netherlands)

    L.A. van Herwerden (Lex); B.A. van Hout (Ben); M-A.M. Morel (Marie-Angèle); F. Unger (Felix); J.E. Sousa (Eduardo); A. Jatene (Adib); J.J.R.M. Bonnier (Hans); J.P.A.M. Schonberger (Jacques); N. Buller (Nigel); R. Bonser (Robert); M.J.B.M. van den Brand (Marcel); P.W.J.C. Serruys (Patrick)

    2001-01-01

    textabstractBACKGROUND: The recent recognition that coronary-artery stenting has improved the short- and long-term outcomes of patients treated with angioplasty has made it necessary to reevaluate the relative benefits of bypass surgery and percutaneous interventions in patients with multivessel

  11. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    International Nuclear Information System (INIS)

    Youn, Sung Won; Kim, Ho Kyun; Do, Jin Kook; Kim, Young Whan

    2011-01-01

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  12. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Sung Won; Kim, Ho Kyun [Dept. of Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Do, Jin Kook [Dept. of Neurology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Whan [Dept. of Radiology, University College of Medicine, Daegu (Korea, Republic of)

    2011-12-15

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  13. A Prospective, Multicenter Study of a Novel Mesh-Covered Carotid Stent: The CGuard CARENET Trial (Carotid Embolic Protection Using MicroNet).

    Science.gov (United States)

    Schofer, Joachim; Musiałek, Piotr; Bijuklic, Klaudija; Kolvenbach, Ralf; Trystula, Mariusz; Siudak, Zbigniew; Sievert, Horst

    2015-08-17

    This study sought to evaluate the feasibility of the CGuard Carotid Embolic Protective Stent system-a novel thin strut nitinol stent combined with a polyethylene terephthalate mesh covering designed to prevent embolic events from the target lesion in the treatment of carotid artery lesions in consecutive patients suitable for carotid artery stenting. The risk of cerebral embolization persists throughout the carotid artery stenting procedure and remains during the stent healing period. A total of 30 consecutive patients (age 71.6 ± 7.6 years, 63% male) meeting the conventional carotid artery stenting inclusion criteria were enrolled in 4 centers in Germany and Poland. The primary combined endpoint was the procedure success of the CGuard system and the number and volume of new lesions on the ipsilateral side assessed by diffusion-weighted magnetic resonance imaging at 48 h post-procedure and at 30 days. The secondary endpoint was 30-day major adverse cardiac or cerebrovascular events (death, stroke, or myocardial infarction). Protection devices were used in all procedures. Procedure success was 100%, with 0% procedural complications. The 30-day major adverse cardiac or cerebrovascular events rate was 0%. New ipsilateral ischemic lesions at 48 h occurred in 37.0% of patients and the average lesion volume was 0.039 ± 0.08 cm(3). The 30-day diffusion-weighted magnetic resonance imaging showed complete resolution of all but 1 periprocedural lesion and only 1 new minor (0.116 cm(3)) lesion in relation to the 48-h scan. The use of the CGuard system in patients undergoing carotid artery stenting is feasible. In addition, the benefit of using CGuard may extend throughout the stent healing period. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Combined application of distal and proximal embolic protection devices in endovascular stenting for severe carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Zhi-hua DU

    2011-09-01

    Full Text Available Objective To analyze and summarize methods and experiences of combined application of distal and proximal embolic protection devices(EPD in endovascular stenting for severe carotid artery stenosis.Methods Five patients with severe stenosis of the common carotid artery or with extracranial segment of the internal carotid artery diagnosed through digital subtraction angiography(DSA from March to July 2010 were involved in the present study.All patients received carotid angioplasty and stenting(CAS,with a combination of distal and proximal EPD via the percutaneous femoral artery approach.Results The operation failed in one patient,whereas technical success with no intraoperative complication was achieved in four patients.The symptoms disappeared or improved in the four cases that achieved technical success.The follow-up duration was one to three months,and no cerebral ischemia was found.Conclusion CAS with the combined application of distal and proximal EPD in some special cases of carotid artery stenosis may surmount the shortage of single EPD,reduce the risk of intraoperative embolization,decrease the time of intraoperative endovascular inflow occlusion,and reduce high-risk operations.CAS may be used as an individualized treatment strategy for patients with carotid artery stenosis.

  15. Stenting in the treatment of acute ischemic stroke: literature review.

    Directory of Open Access Journals (Sweden)

    Edgar A Samaniego

    2011-12-01

    Full Text Available Recanalization of acute large artery occlusions is a strong predictor of good outcome. The development of thrombectomy devices resulted in a significant improvement in recanalization rates compared to thrombolytics alone. However, clinical trials and registries with these thrombectomy devices in acute ischemic stroke (AIS have shown recanalization rates in the range of 40-81%. The last decade has seen the development of nickel titanium self-expandable stents (SES. These stents, in contrast to balloon-mounted stents, allow better navigability and deployment in tortuous vessels and therefore are optimal for the cerebral circulation. SES were initially used for stent-assisted coil embolization of intracranial aneurysms and for treatment of intracranial stenosis. However, a few authors have recently reported feasibility of deployment of SES in AIS. The use of these devices yielded higher recanalization rates compared to traditional thrombectomy devices. Encouraged by these results, retrievable SES systems have been recently used in AIS. These devices offer the advantage of resheathing and retrieving of the stent even after full deployment. Some of these stents can also be detached in case permanent stent placement is needed. Retrievable SES are being used in Europe and currently tested in clinical trials in the United States. We review the recent literature in the use of stents for the treatment of AIS secondary to large vessel occlusion.

  16. The use of intraoperative monitoring and treatment of symptomatic microemboli in carotid artery stenting: case report and discussion

    Energy Technology Data Exchange (ETDEWEB)

    Rangi, P.S.; Clifton, A. [St Georges Hospital, Department of Neuroradiology, Atkinson Morley Wing, Tooting, London (United Kingdom); Markus, H.S.; Punter, M.N.M. [St Georges University of London, Centre for Clinical Neuroscience, Cranmer Terrace, London (United Kingdom)

    2007-03-15

    Carotid artery stenting is a recently introduced treatment in symptomatic atherosclerotic carotid artery disease with acceptable complication rates. The major risk is perioperative embolic stroke. Transcranial Doppler ultrasonography (TCD) can be used to identify embolic signals and guide therapy. We present a case of symptomatic embolization in a 72-year-old female following carotid stent deployment complicated by haemodynamic changes. Despite concurrent dual antiplatelet medication significant symptomatic embolization occurred even after restoration of the blood pressure, and modulation of the rate of embolization was achieved using dextran-40 guided by TCD monitoring. The patient recovered from an initially profound hemiparesis and dysphasia to minor sensory changes. Microemboli are common following carotid artery stenting and there appears to be a threshold phenomenon associated with prolonged embolization and progression to cerebral infarction. TCD can be used to detect particulate microemboli and therefore may be useful in guiding antithrombotic therapy in this setting. Dextran-40 has been shown to reduce the embolic load following carotid endarterectomy and was used to good effect in this patient in terms of both embolic load and clinical outcome. This is the first case of embolization following carotid stenting successfully treated with dextran-40, and offers a further option for therapeutic intervention in microembolism detected by TCD and stresses the importance of perioperative monitoring of embolic load for postoperative stroke risk. (orig.)

  17. Costs and cost-effectiveness of carotid stenting versus endarterectomy for patients at standard surgical risk: results from the Carotid Revascularization Endarterectomy Versus Stenting Trial (CREST).

    Science.gov (United States)

    Vilain, Katherine R; Magnuson, Elizabeth A; Li, Haiyan; Clark, Wayne M; Begg, Richard J; Sam, Albert D; Sternbergh, W Charles; Weaver, Fred A; Gray, William A; Voeks, Jenifer H; Brott, Thomas G; Cohen, David J

    2012-09-01

    The Carotid Revascularization Endarterectomy versus Stenting Trial (CREST) demonstrated similar rates of the primary composite end point between carotid artery stenting (CAS) and carotid endarterectomy (CEA), although the risk of stroke was higher with CAS, and the risk of myocardial infarction was higher with CEA. Given the large number of patients who are candidates for these procedures, an understanding of their relative cost and cost-effectiveness may have important implications for health care policy and treatment guidelines. We performed a formal economic evaluation alongside the CREST trial. Costs were estimated from all trial participants over the first year of follow-up using a combination of resource use data and hospital billing data. Patient-level health use scores were obtained using data from the SF-36. We then used a Markov disease-simulation model calibrated to the CREST results to project 10-year costs and quality-adjusted life expectancy for the 2 treatment groups. Although initial procedural costs were $1025/patient higher with CAS, postprocedure costs and physician costs were lower such that total costs for the index hospitalization were similar for the CAS and CEA groups ($15 055 versus $14 816; mean difference, $239/patient; 95% CI for difference, -$297 to $775). Neither follow-up costs after discharge nor total 1-year costs differed significantly. For the CREST population, model-based projections over a 10-year time horizon demonstrated that CAS would result in a mean incremental cost of $524/patient and a reduction in quality-adjusted life expectancy of 0.008 years compared with CEA. Probabilistic sensitivity analysis demonstrated that CEA was economically attractive at an incremental cost-effectiveness threshold of $50 000/quality-adjusted life-year gained in 54% of samples, whereas CAS was economically attractive in 46%. Despite slightly lower in-trial costs and lower rates of stroke with CEA compared with CAS, projected 10-year outcomes

  18. Asymptotic analysis of blood flow in stented arteries: time dependency and direct simulations***

    Directory of Open Access Journals (Sweden)

    Pichon Gostaf Kirill

    2010-12-01

    Full Text Available This work aims to extend in two distinct directions results recently obtained in [10]. In a first step we focus on the possible extension of our results to the time dependent case. Whereas in the second part some preliminary numerical simulations aim to give orders of magnitudes in terms of numerical costs of direct 3D simulations. We consider, in the first part, the time dependent rough problem for a simplified heat equation in a straight channel that mimics the axial velocity under an oscillating pressure gradient. We derive first order approximations with respect to ϵ, the size of the roughness. In order to understand the problem and set up correct boundary layer approximations, we perform a time periodic fourier analysis and check that no frequency can interact with the roughness. We show rigorously on this toy problem that the boundary layers remain stationary in time (independent on the frequency number. Finally we perform numerical tests validating our theoretical approach. In the second part, we determine actual limits, when running three-dimensional blood flow simulations of the non-homogenized stented arteries. We solve the stationary Stokes equations for an artery containing a saccular aneurysm. Consecutive levels of uniform mesh refinement, serve to relate spatial resolution, problem scale, and required computation time. Test computations are presented for femoral side aneurysm, where a simplified ten-wire stent model was placed across the aneurysm throat. We advocate the proposed stent homogenization model, by concluding that an actual computation power is not sufficient to run accurate, direct simulations of a pulsatile flow in stented vessels.

  19. Safety of Early Carotid Artery Stenting after Systemic Thrombolysis: A Single Center Experience

    Directory of Open Access Journals (Sweden)

    Fabrizio Sallustio

    2012-01-01

    Full Text Available Background. Patients with acute ischemic stroke due to internal carotid artery (ICA disease are at high risk of early stroke recurrence. A combination of IV thrombolysis and early carotid artery stenting (CAS may result in more effective secondary stroke prevention. Objective. We tested safety and durability of early CAS following IV thrombolysis in stroke patients with residual stenosis in the symptomatic ICA. Methods. Of consecutive patients treated with IV rtPA, those with residual ICA stenosis ≥70% or 24 hours. The protocol included pre-rtPA MRI and MR angiography, and post-rtPA carotid ultrasound and CT angiography. Stroke severity was assessed by the NIH Stroke Scale (NIHSS. Three- and twelve-month stent patency was assessed by ultrasound. Twelve-month functional outcome was assessed by the modified Rankin Scale (mRS. Results. Of 145 consecutive IV rtPA-treated patients, 6 (4% underwent early CAS. Median age was 76 (range 67–78 years, median NIHSS at stroke onset was 12 (range 9–16 and 7 (range 7-8 before CAS. Median onset-to-CAS time was 48 (range 30–94 hours. A single self-expandable stent was implanted to cover the entire lesion in all patients. The procedure was uneventful in all patients. After 12 months, all patients had stent patency, and the functional outcome was favourable (mRS ≤ 2 in all but 1 patient experiencing a recurrent stroke for new-onset atrial fibrillation. Conclusion. This small case series of a single centre suggests that early CAS may be considered a safe alternative to CEA after IV rtPA administration in selected patients at high risk of stroke recurrence.

  20. Stenting of the Superior Mesenteric Artery as a Preoperative Treatment for Total Pancreatectomy

    International Nuclear Information System (INIS)

    Tanigawa, Noboru; Kariya, Shuji; Komemushi, Atsushi; Satoi, Sohei; Kamiyama, Yasuo; Sawada, Satoshi; Kojima, Hiroyuki; Sougawa, Mitsuharu; Takai, Yuichirou

    2004-01-01

    The patient was a 58-year-old male with mucinous cyst adenocarcinoma of the pancreas. Prior to total pancreatectomy, preoperative CT and angiography showed a high-grade arteriosclerotic stenosis of about 1.0 cm in length in the ostium of the superior mesenteric artery (SMA), as well as the development of collateral vessels in the area around the head of the pancreas. A stent was placed in the SMA stenosis to preserve the intestinal blood flow in the SMA region after total pancreatectomy, which was performed 25 days after stent placement. The postoperative SMA blood flow was favorable, with no postoperative intestinal ischemia, and the patient had an uneventful postoperative course

  1. Novel 3D-CT evaluation of carotid stent volume: greater chronological expansion of stents in patients with vulnerable plaques.

    Science.gov (United States)

    Itami, Hisakazu; Tokunaga, Koji; Okuma, Yu; Hishikawa, Tomohito; Sugiu, Kenji; Ida, Kentaro; Date, Isao

    2013-09-01

    Although self-expanding carotid stents may dilate gradually, the degrees of residual stenosis have been quantified by the NASCET criteria, which is too simple to reflect the configuration of the stented artery. We measured the volumes of the stent lumens chronologically by 3D-CT in patients after carotid artery stenting (CAS), and analyzed the correlations between the volume change and medical factors. Fourteen patients with carotid artery stenosis were treated using self-expanding, open-cell stents. All patients underwent preoperative plaque MRI (magnetization-prepared rapid acquisition gradient-echo, MPRAGE) and chronological 3D-CT examinations of their stents immediately after their placement and 1 day, 1 week, and 1 month after the procedure. The volume of the stent lumen was measured using a 3D workstation. The correlations between stent volume and various factors including the presence of underlying diseases, plaque characteristics, and the results of the CAS procedure were analyzed. Stent volume gradually increased in each case and had increased by 1.04-1.55 (mean, 1.25)-fold at 1 postoperative month. The presence of underlying medical diseases, plaque length, the degree of residual stenosis immediately after CAS, and plaque calcification did not have an impact on the change in stent volume. On the other hand, the stent volume increase was significantly larger in the patients with vulnerable plaques that demonstrated high MPRAGE signal intensity (P stent volume. Self-expanding stents in carotid arteries containing vulnerable plaques expand significantly more than those without such plaques in a follow-up period.

  2. Stent assisted coil embolization of a dissecting aneurysm of the vertebral artery: a case involving a patient with hypoplasia of the contralateral vertebral artery

    International Nuclear Information System (INIS)

    Kim, Hyun Jin; Jeong, Hae Woong; Cho, Jae Kwoeng; Park, Jeong Hoon; Koo, Yong Woon; Baik, Seung Kug

    2002-01-01

    A dissecting aneurysm of the vertebral artery may be treated conservatively, surgically, or using an endovascular approach. Proximal clipping, wrapping or trapping are surgical treatment methods, and endovascular treatment with coils and balloons is performed where a dissecting aneurysm is located near the midline or the appropriate surgical manipulation is difficult. As the contralateral vertebral artery of this patient was hypoplastic, the stent-assisted coil embolization technique was employed to preserve the ipsilateral vertebral artery. We describe a clinical case of dissecting aneurysm of the vertebral artery occurring in a patient in whom a hypoplastic contralateral vertebral artery was successfully treated

  3. [Absorbable coronary stents. New promising technology].

    Science.gov (United States)

    Erbel, Raimund; Böse, Dirk; Haude, Michael; Kordish, Igor; Churzidze, Sofia; Malyar, Nasser; Konorza, Thomas; Sack, Stefan

    2007-06-01

    Coronary stent implantation started in Germany 20 years ago. In the beginning, the progress was very slow and accelerated 10 years later. Meanwhile, coronary stent implantation is a standard procedure in interventional cardiology. From the beginning of permanent stent implantation, research started to provide temporary stenting of coronary arteries, first with catheter-based systems, later with stent-alone technology. Stents were produced from polymers or metal. The first polymer stent implantation failed except the Igaki-Tamai stent in Japan. Newly developed absorbable polymer stents seem to be very promising, as intravascular ultrasound (IVUS) and optical coherence tomography have demonstrated. Temporary metal stents were developed based on iron and magnesium. Currently, the iron stent is tested in peripheral arteries. The absorbable magnesium stent (Biotronik, Berlin, Germany) was tested in peripheral arteries below the knee and meanwhile in the multicenter international PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) study. The first magnesium stent implantation was performed on July 30, 2004 after extended experimental testing in Essen. The magnesium stent behaved like a bare-metal stent with low recoil of 5-7%. The stent struts were absorbed when tested with IVUS. Stent struts were not visible by fluoroscopy or computed tomography (CT) as well as magnetic resonance imaging (MRI). That means, that the magnesium stent is invisible and therefore CT and MRI can be used for imaging of interventions. Only using micro-CT the stent struts were visible. The absorption process could be demonstrated in a patient 18 days after implantation due to suspected acute coronary syndrome, which was excluded. IVUS showed a nice open lumen. Stent struts were no longer visible, but replaced by tissue indicating the previous stent location. Coronary angiography after 4 months showed an ischemia-driven target lesion

  4. Stents in Renal Artery Bifurcation Stenosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Polytimi Leonardou

    2011-01-01

    Full Text Available A 39-year-old patient presented with poorly controlled hypertension, and she was referred to renal angiogram and potential renal angioplasty. Renal angiogram showed a bifurcation lesion of the right renal artery. A guide wire was used to cross the upper branch, while the lower branch was protected by another same-type guide wire through the same introducer. Two thin monorail balloons were used to dilate the two branches; however, despite balloon dilatation, the stenosis of the vessels persisted. The “kissing balloon” technique was then attempted by simultaneously inflating both branches using the same balloons, but more than a 70% residual stenosis persisted in each branch. Two stents were finally placed in a “kissing” way through the main renal artery. The imaging and clinical results were good, without any procedure-related complications. Three years clinical followup was also good, without any reason for further interventional approach.

  5. Stents in Renal Artery Bifurcation Stenosis: A Case Report

    Science.gov (United States)

    Leonardou, Polytimi; Pappas, Paris

    2011-01-01

    A 39-year-old patient presented with poorly controlled hypertension, and she was referred to renal angiogram and potential renal angioplasty. Renal angiogram showed a bifurcation lesion of the right renal artery. A guide wire was used to cross the upper branch, while the lower branch was protected by another same-type guide wire through the same introducer. Two thin monorail balloons were used to dilate the two branches; however, despite balloon dilatation, the stenosis of the vessels persisted. The “kissing balloon” technique was then attempted by simultaneously inflating both branches using the same balloons, but more than a 70% residual stenosis persisted in each branch. Two stents were finally placed in a “kissing” way through the main renal artery. The imaging and clinical results were good, without any procedure-related complications. Three years clinical followup was also good, without any reason for further interventional approach. PMID:21789043

  6. Optimal Treatment of the ‘High-Risk’ Patient with Carotid Artery Stenosis

    NARCIS (Netherlands)

    Fokkema, T.M.

    2013-01-01

    Four landmark randomized trials have clearly validated the use of carotid endarterectomy (CEA) for the management of asymptomatic and symptomatic significant carotid artery stenosis. However, its risk-to-benefit ratio is variable for different patients. With the advent of carotid artery stenting

  7. Stenting for symptomatic vertebral artery stenosis associated with bilateral carotid rate mirabile: The long-term clinical and angiographic outcome

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jang Hyun; Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    Symptomatic vertebral artery (VA) stenosis associated with bilateral carotid rate mirabile (CRM) has not been reported. We report the long-term clinical and angiographic outcome after stenting for symptomatic VA stenosis in the patient with bilateral CRM. This report is the first case that symptomatic VA stenosis associated with bilateral CRM was treated with stenting.

  8. Stenting for symptomatic vertebral artery stenosis associated with bilateral carotid rate mirabile: The long-term clinical and angiographic outcome

    International Nuclear Information System (INIS)

    Baek, Jang Hyun; Kim, Byung Moon

    2015-01-01

    Symptomatic vertebral artery (VA) stenosis associated with bilateral carotid rate mirabile (CRM) has not been reported. We report the long-term clinical and angiographic outcome after stenting for symptomatic VA stenosis in the patient with bilateral CRM. This report is the first case that symptomatic VA stenosis associated with bilateral CRM was treated with stenting.

  9. The Erasme Study: A Multicenter Study on the Safety and Technical Results of the Palmaz Stent Used for the Treatment of Atherosclerotic Ostial Renal Artery Stenosis

    International Nuclear Information System (INIS)

    Bakker, Jeannette; Goffette, Pierre P.; Henry, Michel; Mali, Willem P.T.M.; Melki, Jean-Pierre; Moss, Jon G.; Rabbia, Claudio; Therasse, Eric; Thomson, Kenneth R.; Thurnher, Siegfried; Vignali, Claudio

    1999-01-01

    Purpose: To assess, in a multicenter setting, safety, technical results, and restenosis rate of the Palmaz stent for treatment of atherosclerotic ostial renal artery stenosis. Methods: Ten centers enrolled 106 patients (120 treated renal artery stenoses) in the study. Patient selection was based on unsuccessful percutaneous transluminal renal angioplasty (residual stenosis ≥ 20%) performed for treatment of ostial stenosis ≥ 50%, in patients with hypertension and/or impaired renal function. Safety was assessed by means of the complication rate, and technical results by the number of successful stent placements and occurrence of restenosis (>50%) at intraarterial angiographic follow-up. Results: Stent placement was successful (n = 112) or partially successful (n = 5) in 117 (98%) arteries. Complications occurred in 19 procedures; seven were of serious clinical significance. Angiographic follow-up was performed in 89 of 117 (76%) cases, at a mean of 8 months (range 2.5-18 months). Fifteen stents (16.9%) showed restenosis (at a mean of 8.5 months), of which 10 were successfully redilated. Conclusion: Renal artery stenting has a high technical success rate, a complication rate comparable to percutaneous transluminal renal angioplasty, and a low rate of restenosis at 8 months angiographic follow-up

  10. Double Kissing Crush Versus Provisional Stenting for Left Main Distal Bifurcation Lesions: DKCRUSH-V Randomized Trial.

    Science.gov (United States)

    Chen, Shao-Liang; Zhang, Jue-Jie; Han, Yaling; Kan, Jing; Chen, Lianglong; Qiu, Chunguang; Jiang, Tiemin; Tao, Ling; Zeng, Hesong; Li, Li; Xia, Yong; Gao, Chuanyu; Santoso, Teguh; Paiboon, Chootopol; Wang, Yan; Kwan, Tak W; Ye, Fei; Tian, Nailiang; Liu, Zhizhong; Lin, Song; Lu, Chengzhi; Wen, Shangyu; Hong, Lang; Zhang, Qi; Sheiban, Imad; Xu, Yawei; Wang, Lefeng; Rab, Tanveer S; Li, Zhanquan; Cheng, Guanchang; Cui, Lianqun; Leon, Martin B; Stone, Gregg W

    2017-11-28

    Provisional stenting (PS) is the most common technique used to treat distal left main (LM) bifurcation lesions in patients with unprotected LM coronary artery disease undergoing percutaneous coronary intervention. The double kissing (DK) crush planned 2-stent technique has been shown to improve clinical outcomes in non-LM bifurcations compared with PS, and in LM bifurcations compared with culotte stenting, but has never been compared with PS in LM bifurcation lesions. The authors sought to determine whether a planned DK crush 2-stent technique is superior to PS for patients with true distal LM bifurcation lesions. The authors randomized 482 patients from 26 centers in 5 countries with true distal LM bifurcation lesions (Medina 1,1,1 or 0,1,1) to PS (n = 242) or DK crush stenting (n = 240). The primary endpoint was the 1-year composite rate of target lesion failure (TLF): cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Routine 13-month angiographic follow-up was scheduled after ascertainment of the primary endpoint. TLF within 1 year occurred in 26 patients (10.7%) assigned to PS, and in 12 patients (5.0%) assigned to DK crush (hazard ratio: 0.42; 95% confidence interval: 0.21 to 0.85; p = 0.02). Compared with PS, DK crush also resulted in lower rates of target vessel myocardial infarction I (2.9% vs. 0.4%; p = 0.03) and definite or probable stent thrombosis (3.3% vs. 0.4%; p = 0.02). Clinically driven target lesion revascularization (7.9% vs. 3.8%; p = 0.06) and angiographic restenosis within the LM complex (14.6% vs. 7.1%; p = 0.10) also tended to be less frequent with DK crush compared with PS. There was no significant difference in cardiac death between the groups. In the present multicenter randomized trial, percutaneous coronary intervention of true distal LM bifurcation lesions using a planned DK crush 2-stent strategy resulted in a lower rate of TLF at 1 year than a PS

  11. The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Chee, Hyun Keun; Park, Sang Woo; Yun, Ik Jin; Hwang, Jae Joon; Lee, Song Am; Kim, Jun Seok; Chang, Seong Hwan; Jung, Hong Geun [Konkuk University Hospital, Seoul (Korea, Republic of)

    2011-04-15

    We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at the 2-year follow-up did not have stent fracture. The primary patency was 94%, 61% and 44% at 1, 3 and 6 months, respectively, and the group with stent implantation up to P3 had a higher fracture rate than that of the group that underwent stenting up to P2 (p < 0.05). We suggest that stent placement up to the popliteal arterial P3 segment and over P2 in an Asian population can worsen the stent patency owing to stent fracture. It may be necessary to develop a stent design and structure for the Asian population that can resist the bending force in the knee joint

  12. Drug-eluting or bare-metal stents for large coronary vessel stenting? The BASKET-PROVE (PROspective Validation Examination) trial: Study protocol and design

    DEFF Research Database (Denmark)

    Pfisterer, M.; Bertel, O.; Bonetti, P.O.

    2008-01-01

    or refute this hypothesis, we set up an 11-center 4-country prospective trial of 2260 consecutive patients treated with >= 3.0-mm stents only, randomized to receive Cypher (Johnson & Johnson, Miami Lakes, FL), Vision (Abbott Vascular, Abbott Laboratories, IL), or Xience stents (Abbott Vascular). Only...

  13. Safety of Carotid Artery Stenting in Elderly Patients with Severe Carotid Artery Stenosis

    International Nuclear Information System (INIS)

    Choi, Seul Kee; Kim, Seul Kee; Jeong, Min Young; Yoon, Woong

    2012-01-01

    To determine the safety of carotid artery stenting (CAS) using an emboli-protection device in elderly patients with severe carotid artery stenosis. Ninety consecutive patients who were at high risk for carotid endarterectomy underwent protected CAS using an emboli-protection device. Patients were divided into two groups by age: < 70 and ≥ 70. The primary outcome measure was the combined incidence of stroke, myocardial infarction (MI), and death within 30 days of CAS. The secondary outcome measures were technical success and hyperperfusion syndrome. Associations between age and the clinical outcomes were investigated. Overall, 30-day stroke, MI, and death rates were 6.7%. There was no significant difference in the primary outcome between the older age group (n = 56) and younger age group (n = 34) (8.9% and 2.9%, respectively; HR for age ≥ 70, 1.141; 95% CI, 0.875 to 1.488, p = 0.331). A logistic regression showed there was no independent variable associated with primary outcome. Technical success was achieved in all patients and there was no significant difference in the incidence of hyperperfusion syndrome between the two age groups. The results of this study suggest that protected CAS seems to be safe in elderly patients with severe carotid artery stenosis.

  14. Insertion of Self-Expandable Nitinol Stents Without Previous Balloon Angioplasty Reduces Restenosis Compared with PTA Prior to Stenting

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Stenram, Unne; Cwikiel, Wojciech

    2002-01-01

    Purpose: To compare the development of intimal hyperplasia after deployment of a self-expanding nitinol stent with and without previous percutaneous transluminal balloon angioplasty (PTA), with the results after PTA alone. Methods: In nine healthy pigs, the iliac arteries were divided into three groups: group 1 (n = 6 arteries) was treated with PTA; group 2 n 6)with insertion of self-expanding stents after PTA; and group 3 (n = 6) with stent insertion without previous PTA. After 8 weeks the vessels were examined with intravascular ultrasonography,histologic examination and morphometric analysis. Results: Although the injury index in group 1 (0.17± 0.57) was lower (p <0.05) than in group 2 (0.26 ± 0.06) and group 3 (0.26 ± 0.08), PTA-treated arteries showed significantly (p <0.05) reduced mean luminal gain (0.53 ± 2.84) compared with arteries treated with PTA prior to stenting (2.58 ± 1.38) and compared with stenting alone (4.65 ±5.34). Stenting after PTA resulted in a higher (p<0.05) restenosis index (2.63 ± 1.06) compared with stenting without PTA (1.35 ± 0.59). Group 2 also had a significantly thicker intimap <0.05) and 83% and 74% higher intima/mediaratio (p <0.05) compared with groups 1 and 3, respectively. Conclusion: Insertion of a self-expandable nitinol stent without previous PTA results in less intimalhyperplasia than if PTA is performed prior to stenting, suggesting that direct stenting can be used in angioplasty sessions with a favorable outcome

  15. Bioresorbable scaffolds in the treatment of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Zhang Y

    2013-03-01

    Full Text Available Yaojun Zhang,1,2 Christos V Bourantas,1 Vasim Farooq,1 Takashi Muramatsu,1 Roberto Diletti,1 Yoshinobu Onuma,1 Hector M Garcia-Garcia,1 Patrick W Serruys11Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands; 2Division of Cardiovascular Diseases, Nanjing First Hospital, Nanjing Medical University, Nanjing, People's Republic of ChinaAbstract: Drug-eluting stents have reduced the risk of in-stent restenosis and have broadened the application in percutaneous coronary intervention in coronary artery disease. However, the concept of using a permanent metallic endovascular device to restore the patency of a stenotic artery has inherited pitfalls, namely the presence of a foreign body within the artery causing vascular inflammation, late complications such as restenosis and stent thrombosis, and impeding the restoration of the physiologic function of the stented segment. Bioresorbable scaffolds (BRS were introduced to potentially overcome these limitations, as they provide temporary scaffolding and then disappear, liberating the treated vessel from its cage. Currently, several BRSs are available, undergoing evaluation either in clinical trials or in preclinical settings. The aim of this review is to present the new developments in BRS technology, describe the mechanisms involved in the resorption process, and discuss the potential future prospects of this innovative therapy.Keywords: bioresorbable scaffold, drug-eluting stent, biodegradable, design, mechanism, coronary artery disease

  16. Subclavian artery stenosis caused by non-specific arteritis (Takayasu disease): treatment with Palmaz stent

    Energy Technology Data Exchange (ETDEWEB)

    Maskovic, J.; Jankovic, S.; Lusic, I.; Cambj-Sapunar, L.; Mimica, Z.; Bacic, A

    1999-09-01

    A 32-year old woman was admitted to the hospital with a sudden onset of right-sided hemiplegia and aphasia. Immediate angiographic examination revealed a severe form of type I Takayasu arteritis with occlusion of all supra-aortic vessels, with the exception of the left subclavian artery which was, however, almost completely occluded 1 cm proximal to the origin of the left vertebral artery. Since the latter provided the entire blood supply to the brain tissues, an immediate attempt was undertaken to dilate the left subclavian artery; when this was unrewarding, stenting of the lesion was successfully accomplished with excellent primary and 6-month follow-up results.

  17. Subclavian artery stenosis caused by non-specific arteritis (Takayasu disease): treatment with Palmaz stent

    International Nuclear Information System (INIS)

    Maskovic, J.; Jankovic, S.; Lusic, I.; Cambj-Sapunar, L.; Mimica, Z.; Bacic, A.

    1999-01-01

    A 32-year old woman was admitted to the hospital with a sudden onset of right-sided hemiplegia and aphasia. Immediate angiographic examination revealed a severe form of type I Takayasu arteritis with occlusion of all supra-aortic vessels, with the exception of the left subclavian artery which was, however, almost completely occluded 1 cm proximal to the origin of the left vertebral artery. Since the latter provided the entire blood supply to the brain tissues, an immediate attempt was undertaken to dilate the left subclavian artery; when this was unrewarding, stenting of the lesion was successfully accomplished with excellent primary and 6-month follow-up results

  18. Coronary and peripheral stenting in aorto-ostial protruding stents: The balloon assisted access to protruding stent technique.

    Science.gov (United States)

    Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R

    2016-03-01

    Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.

  19. Are bio-absorbable stents the future of SFA treatment?

    Science.gov (United States)

    Peeters, P; Keirse, K; Verbist, J; Deloose, K; Bosiers, M

    2010-02-01

    Several limitations inherent to the implantation of a metallic device, such as the occurrence of in-stent re-stenosis, in an arterial lumen intuitively explain the interest for developing bio-absorbable stents. Two main types of bio-absorbable stents currently exist: polymer stents and metallic stents. To date, no studies with bio-absorbable stents have been conducted in the superficial femoral artery (SFA). Because of their strut thickness and lack of radial force, polymer stents are no good candidates for endovascular use. Absorbable metal stents (AMS) do have the potential to perform well for artery treatment, although current evidence from in-human coronary and infrapopliteal studies yield unsatisfactory results. Drastic technological improvements are mandatory before AMS can be considered for every day practice. Yet, it is our belief that further development of other metal and non-metal bio-absorbable stents, with or without drug-coating, may lead to the creation of the ultimate SFA stent.

  20. Vertebral artery ostial stent placement for atherosclerotic stenosis in 72 consecutive patients: clinical outcomes and follow-up results

    International Nuclear Information System (INIS)

    Taylor, Robert A.; Memon, Muhammad Zeeshan; Qureshi, Adnan I.; Vazquez, Gabriela; Siddiq, Farhan; Hayakawa, Minako; Chaloupka, John C.

    2009-01-01

    The study's purpose is to report the technical and clinical outcomes of a patient cohort that underwent vertebral artery ostium stent placement for atherosclerotic stenosis. We retrospectively analyzed a prospectively collected database of neurointerventional procedures performed at a single center from 1999 to 2005. Outcome measures included recurrent transient neurological deficits (TNDs), stroke, and death. Kaplan-Meier analysis was used to estimate stroke- and/or death-free survival at 12 months. Cox proportional hazard was used to identify risk factors for recurrent vertebrobasilar ischemic events. Seventy-two patients with 77 treated vertebral ostial lesions were included. The 30-day stroke and/or death rate was 5.2% (n = 4), although no event was directly related to the vertebral ostium stent placement. Three procedure-related strokes were secondary to attempted stent placement at other sites (one carotid artery and two basilar arteries), and the one death was secondary to the presenting stroke severity. The mean clinical follow-up time available for 66 patients was 9 months. There were 14 TNDs (21%), two strokes (3%), and two deaths (3%) recorded in the follow-up. Recurrent vertebrobasilar ischemic events occurred in nine patients (seven TNDs and two strokes). No recurrent stroke and/or deaths were related to the treated vertebral ostium. Stroke- and/or death-free survival rate (including periprocedural stroke and/or death) was 89 ± 5% at 12 months. No vascular risk factor was significantly associated with recurrent vertebrobasilar ischemic events. Vertebral artery ostium stent placement can be safely and effectively performed with a low rate of recurrent stroke in the territory of the treated vessel. Patients who also underwent attempted treatment of a tandem intracranial stenosis appeared to be at highest risk for periprocedure stroke. (orig.)

  1. How to manage hypertension with atherosclerotic renal artery stenosis?

    Science.gov (United States)

    Ricco, Jean-Baptiste; Belmonte, Romain; Illuminati, Guilio; Barral, Xavier; Schneider, Fabrice; Chavent, Bertrand

    2017-04-01

    The management of atherosclerotic renal artery stenosis (ARAS) in patients with hypertension has been the topic of great controversy. Major contemporary clinical trials such as the Cardiovascular Outcomes for Renal Artery lesions (CORAL) and Angioplasty and Stenting for Renal Atherosclerotic lesions (ASTRAL) have failed to show significant benefit of revascularization over medical management in controlling blood pressure and preserving renal function. We present here the implications and limitations of these trials and formulate recommendations for management of ARAS.

  2. [Fully absorbable drug eluting coronary stent: where do we stand in 2014?].

    Science.gov (United States)

    Kočka, Viktor; Toušek, Petr; Lisa, Libor; Buděšínský, Tomáš

    2014-04-01

    Coronary stent is routinely used in majority percutaneous coronary interventions for a long time. They have an important role, especially, in the first months after intervention. We can consider as a breakthrough point the development of stent which has ability to absorb in intervened artery after a few years. The review presents current techniques of fully absorbable coronary stents and also provides clinical trials and experiences available in 2014. The article continues with discussion between supporters and opponents of this new technique, but definitive conclusion can't be done yet. The authors conclude the review with their own opinion. There are many encouraging data in patients with good clinical outcome after implantation of absorbable stents in more than 10 years follow-up.

  3. Artery Soft-Tissue Modelling for Stent Implant Training System

    Directory of Open Access Journals (Sweden)

    Giovanni Aloisio

    2004-08-01

    Full Text Available Virtual reality technology can be utilised to provide new systematic training methods for surgical procedures. Our aim is to build a simulator that allows medical students to practice the coronary stent implant procedure and avoids exposing patients to risks. The designed simulation system consists of a virtual environment and a haptic interface, in order to provide both the visualization of the coronary arteries and the tactile and force feedback generated during the interactions of the surgical instruments in the virtual environment. Since the arteries are soft tissues, their shape may change during an operation; for this reason physical modelling of the organs is necessary to render their behaviour under the influence of surgeon's instruments. The idea is to define a model that computes the displacement of the tissue versus time; from the displacement it is possible to calculate the response of the tissue to the surgical tool external stimuli. Information about tools displacements and tissue responses are also used to graphically model the artery wall and virtual surgical instrument deformations generated as a consequence of their coming into contact. In order to obtain a realistic simulation, the Finite Element Method has been used to model the soft tissues of the artery, using linear elasticity to reduce computational time and speed up interaction rates.

  4. Randomized clinical comparison of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent with the sirolimus-eluting Orsiro stent in patients treated with percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jakobsen, Lars; Christiansen, Evald H; Maeng, Michael

    2018-01-01

    Background: The Combo stent (OrbusNeich, Hoevelaken, the Netherlands) combining an abluminal, bioabsorbable polymer eluting sirolimus with a luminal CD34+ antibody to capture endothelial progenitor cells has been developed to further improve safety and efficacy of coronary interventions. We have...... designed a large-scale registry-based randomized clinical trial to compare the Combo stent to the Orsiro stent (Biotronik, Bülach, Switzerland) in patients undergoing percutaneous coronary intervention. Methods: The SORT OUT X study will randomly assign 3,140 patients to treatment with Combo or Orsiro...... stents at 3 sites in Western Denmark. Patients are eligible if they are ≥18 years old, have chronic stable coronary artery disease or acute coronary syndromes, and have ≥1 coronary lesion with >50% diameter stenosis requiring treatment with a drug-eluting stent. The primary end point target lesion...

  5. Self-expanding stent-assisted middle cerebral artery recanalization: technical note

    International Nuclear Information System (INIS)

    Sauvageau, Eric; Levy, Elad I.

    2006-01-01

    Investigation into pharmacological and mechanical means of improving recanalization rates by intraarterial therapy has led to technological development. Angiographic recanalization has been associated with improvement in clinical outcome. A clot retriever has recently joined an imperfect armamentarium for intraarterial stroke therapy. In this report, we describe successful recanalization of an acute thrombotic occlusion of the inferior division of the middle cerebral artery (MCA) achieved with a self-expanding stent. An 82-year-old woman with a history of coronary atherosclerosis and previous cerebellar hemorrhage presented with a National Institutes of Health Stroke Scale (NIHSS) score of 11. Perfusion computed tomography imaging showed a left MCA territory deficit. Diffusion-weighted magnetic resonance (MR) imaging revealed a small punctiform insular hyperintensity. Angiography documented occlusion of the inferior division of the left MCA (Thrombolysis in Myocardial Infarction or Thrombolysis in Cerebral Infarction, TIMI/TICI, grade 0). Intraarterial delivery of eptifibatide to the occlusion site failed to recanalize the vessel. Deployment of a self-expanding stent in the occluded segment resulted in complete revascularization of the distal vascular bed. Angiography performed on the next day confirmed patency of the stented vessel segment (TIMI/TICI 3). The patient was discharged 3 days after the procedure (NIHSS 3). MR angiography obtained 3 months after the procedure documented left MCA patency. This technique may have a role worthy of further investigation in acute stroke therapy. (orig.)

  6. Stented Vessels: A Challenge for Histological Preparation and Microscopy

    Directory of Open Access Journals (Sweden)

    Andrea Nolte

    2013-06-01

    Full Text Available Objective: The first procedure to treat blocked coronary arteries was coronary artery bypass graft surgery. In 1977, Andreas Gruntzig introduced percutaneous transluminal coronary angioplasty (PTCA. Today, several stent systems exist ranging from bare metal stents to various drug-eluting stents. Unfortunately, our understanding of the arterial reaction to stent implantation is incomplete – primarily due to technical limitations in the histological study of stented vascular tissue. Methods: In our study, we examined different histological preparation methods based on the embedding material methacrylate. The procedure of embedding and sectioning stented porcine arteries was optimized for the specific requirements, like histochemistry, immunohistochemistry or pre-stained fluorescence. Furthermore, we used a microscopical technique described as fluorescence intensity decay shape analysis microscopy (FIDSAM to eliminate auto-fluorescence from fluorescently labeled tissue. Results: The sections were suitable for histochemical and immunohistochemical staining. Additionally, pre-labeled fluorescence in the porcine tissue was not lost by the embedding process. The evaluation of arterial cross sections with FIDSAM technology gave new, very important insights into the examination possibilities of fluorescently labeled tissue. Conclusions: Future studies of the vascular response to a variety of new stent materials will provide important clues to the pathogenesis resulting in restenosis and occlusion of stents. [J Interdiscipl Histopathol 2013; 1(3.000: 104-112

  7. Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-01-01

    Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  8. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery disease who we...

  9. Renal Infarction Caused by Spontaneous Renal Artery Dissection: Treatment with Catheter-Directed Thrombolysis and Stenting

    International Nuclear Information System (INIS)

    Jeon, Yong Sun; Cho, Soon Gu; Hong, Ki Cheon

    2009-01-01

    Spontaneous renal artery dissection (SRAD) is rare and presents a diagnostic and therapeutic challenge. We report a case of a 36-year-old man who had an SRAD-complicated renal infarction. The patient experienced severe unilateral flank pain. Enhanced abdominal computed axial tomography scan showed renal infarction, and urinalysis showed no hematuria. Selective renal angiography was essential to evaluate the extent of dissection and suitability for repair. The patient was treated with catheter-directed thrombolysis and frenal artery stenting.

  10. Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model

    Science.gov (United States)

    Wang, Hong-Yang; Liu, Long-Shan; Cao, Hai-Ming; Li, Jun; Deng, Rong-Hai; Fu, Qian; Zhang, Huan-Xi; Fei, Ji-Guang; Wang, Chang-Xi

    2017-01-01

    Background: Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment. Methods: Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed. The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups: the normal, stenotic, and stented groups. Hemodynamic parameters including pressure distribution, velocity, wall shear stress (WSS), and mass flow rate (MFR) were extracted. The data of hemodynamic parameters were expressed as median (interquartile range), and Mann–Whitney U-test was used for analysis. Results: Totally, 6 normal, 12 stenotic, and 6 stented TRAs were included in the analysis. TRAS presented nonuniform pressure distribution, adverse pressure gradient across stenosis throat, flow vortex, and a separation zone at downstream stenosis. Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14, 3.30] vs. 1.06 [0.89, 1.15] m/s, 256.5 [149.8, 349.4] vs. 41.7 [37.8, 45.3] Pa at end diastole, P = 0.001; 3.25 [2.67, 3.56] vs. 1.65 [1.18, 1.72] m/s, 281.3 [184.3, 364.7] vs. 65.8 [61.2, 71.9] Pa at peak systole, P = 0.001) and lower minimal WSS and MFRs (0.07 [0.03, 0.13] vs. 0.52 [0.45, 0.67] Pa, 1.5 [1.0, 3.0] vs. 11.0 [8.0, 11.3] g/s at end diastole, P = 0.001; 0.08 [0.03, 0.19] vs. 0.70 [0.60, 0.81] Pa, 2.0 [1.3, 3.3] vs. 16.5 [13.0, 20.3] g/s at peak systole, P = 0.001) as compared to normal arteries. Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS. Conclusions: Hemodynamic factors were significantly changed in severe TRAS. Stent implantation can restore or

  11. Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model.

    Science.gov (United States)

    Wang, Hong-Yang; Liu, Long-Shan; Cao, Hai-Ming; Li, Jun; Deng, Rong-Hai; Fu, Qian; Zhang, Huan-Xi; Fei, Ji-Guang; Wang, Chang-Xi

    Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment. Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed. The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups: the normal, stenotic, and stented groups. Hemodynamic parameters including pressure distribution, velocity, wall shear stress (WSS), and mass flow rate (MFR) were extracted. The data of hemodynamic parameters were expressed as median (interquartile range), and Mann-Whitney U-test was used for analysis. Totally, 6 normal, 12 stenotic, and 6 stented TRAs were included in the analysis. TRAS presented nonuniform pressure distribution, adverse pressure gradient across stenosis throat, flow vortex, and a separation zone at downstream stenosis. Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14, 3.30] vs. 1.06 [0.89, 1.15] m/s, 256.5 [149.8, 349.4] vs. 41.7 [37.8, 45.3] Pa at end diastole, P= 0.001; 3.25 [2.67, 3.56] vs. 1.65 [1.18, 1.72] m/s, 281.3 [184.3, 364.7] vs. 65.8 [61.2, 71.9] Pa at peak systole, P= 0.001) and lower minimal WSS and MFRs (0.07 [0.03, 0.13] vs. 0.52 [0.45, 0.67] Pa, 1.5 [1.0, 3.0] vs. 11.0 [8.0, 11.3] g/s at end diastole, P= 0.001; 0.08 [0.03, 0.19] vs. 0.70 [0.60, 0.81] Pa, 2.0 [1.3, 3.3] vs. 16.5 [13.0, 20.3] g/s at peak systole, P= 0.001) as compared to normal arteries. Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS. Hemodynamic factors were significantly changed in severe TRAS. Stent implantation can restore or ameliorate deleterious change of hemodynamic

  12. Revascularization for Left Main and Multivessel Coronary Artery Disease: Current Status and Future Prospects after the EXCEL and NOBLE Trials.

    Science.gov (United States)

    Al-Hijji, Mohammed; El Sabbagh, Abdallah; Holmes, David R

    2018-06-01

    Revascularization of severe left main and multivessel coronary artery disease has been shown to improve survival in both stable ischemic heart disease and acute coronary syndrome. While revascularization with coronary artery bypass surgery for these disease entities carries class I recommendation in most current guidelines, recent trials has shown potential comparable survival and cardiovascular outcomes between percutaneous and surgical interventions in patients with less complex coronary anatomy. Despite the conflicting results observed in the most recent left main revascularization trials, Everolimus-Eluting Stents or Bypass Surgery for Left Main Coronary Artery Disease (EXCEL) and Nordic-Baltic-British left main revascularization (NOBLE), both treatment strategies remain important for the management of left main disease (LMD) and multivessel disease (MVD) reflecting on the importance of heart team discussion. This review is focused on revascularization of LMD and MVD in patients who are not presenting with ST-segment elevation myocardial infarction, encompassing the evidence from historic and contemporary trials which shaped up current practices. This review discusses the heart team approach to guide decision making, including special populations that are not represented in clinical trials. Copyright © 2018. The Korean Society of Cardiology.

  13. Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis

    International Nuclear Information System (INIS)

    Mueller-Huelsbeck, S.; Jahnke, T.; Grimm, J.; Behm, C.; Hilbert, C.; Frahm, C.; Biederer, J.; Brossmann, J.; Heller, M.

    2002-01-01

    Objective: To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). Patients and Methods: During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink TM 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfermoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88% ±10 and 9 mm ±5. Results: Renal stent implantation was technically successful in all cases (100%). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg ± 10 before to 1 mmHg ± 1.8 after the procedure. Remaining stenosis measured 0.7% ±4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n.s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p [de

  14. Emergency Stent Grafting After Unsuccessful Surgical Repair of a Mycotic Common Femoral Artery Pseudoaneurysm in a Drug Abuser

    International Nuclear Information System (INIS)

    Lupattelli, Tommaso; Garaci, Francesco Giuseppe; Basile, Antonio; Minnella, Daniela Paola; Casini, Andrea; Clerissi, Jacques

    2009-01-01

    Mycotic false aneurysm caused by local arterial injury from attempted intravenous injections in drug addicts remains a challenging clinical problem. The continued increase in drug abuse has resulted in an increased incidence of this problem, particularly in high-volume urban centres. In the drug-abusing population, mycotic arterial pseudoaneurysms most often occur because of missed venous injection and are typically seen in the groin, axilla, and antecubital fossa. Mycotic aneurysms may lead to life-threatening haemorrhage, limb loss, sepsis, and even death. Any soft-tissue swelling in the vicinity of a major artery in an intravenous drug abuser should be suspected of being a false aneurysm until proven otherwise and should prompt immediate referral to a vascular surgeon for investigation and management. We report a case of rupturing mycotic pseudoaneurysm of the left common femoral artery treated by surgical resection followed by vessel reconstruction with autologous material. Unfortunately, at the time of discharge a sudden leakage from the vein graft anastomosis occurred, with subsequent massive bleeding, and required emergent endovascular covered stenting. To the best of our knowledge, this is the first reported case of femoral artery bleeding in a drug abuser treated by stent graft placement.

  15. Patient- and lesion-tailored algorithm of endovascular treatment for arterial occlusive disease of extracranial arteries supplying the brain: safety of the treatment at 30-day follow-up.

    Science.gov (United States)

    Latacz, Paweł; Simka, Marian; Brzegowy, Paweł; Janas, Piotr; Kazibudzki, Marek; Pieniążek, Piotr; Ochała, Andrzej; Popiela, Tadeusz; Mrowiecki, Tomasz

    2017-01-01

    Although surgical endarterectomy remains the treatment of choice for carotid artery stenosis, stenting plays an important role as an alternative treatment modality, especially in high-risk patients. The actual safety profile associated with stenting procedures is probably better than that reported by randomized controlled trials. To assess the safety of stent implantations in extracranial arteries supplying the brain, and also to identify risk factors associated with this procedure. This was a post hoc analysis, with 30-day follow-up. We analyzed the results of treatment of 372 patients who underwent 408 procedures, 197 such procedures in asymptomatic, and 211 in symptomatic individuals. Stenting procedures were performed using a technique and armamentarium which were tailored to the type and anatomy of lesions. There were 6 (1.5%) strokes, including 2 (0.5%) major strokes, 1 ipsi- and 1 contralateral, and 4 (1.0%) minor strokes. In asymptomatic patients there was 1 (0.3%) minor stroke. Transient ischemic attacks occurred in 5 (1.2%) patients. There were 2 (0.5%) non-STEMI myocardial infarctions and 2 (0.5%) non-stroke related fatalities. Risk factors of these adverse events were diabetes mellitus, lesions localized in a tortuous segment of the artery, embolic material in the filter and bilateral stenoses of carotid arteries. Additional risk factors in asymptomatic patients were renal impairment and advanced coronary artery disease; and in symptomatic patients, grade 3 arterial hypertension, dislipidemia, cigarette smoking and lesions requiring predilatation. Stenting procedures of extracranial arteries supplying the brain, which are tailored to the type and anatomy of lesions, seem to be relatively safe.

  16. Design and modeling balloon-expandable coronary stent for manufacturability

    Science.gov (United States)

    Suryawan, D.; Suyitno

    2017-02-01

    Coronary artery disease (CAD) is a disease that caused by narrowing of the coronary artery. The narrowing coronary artery is usually caused by cholesterol-containing deposit (plaque) which can cause a heart attack. CAD is the most common cause mortality in Indonesia. The commonly CAD treatment use the stent to opens or alleviate the narrowing coronary artery. In this study, the stent design is optimized for the manufacturability. Modeling is used to determine the free stent expansion due to applied pressure in the inner surface of the stent. The stress distribution, outer diameter change, and dogboning phenomena are investigated in the simulation. The result of modeling and simulating was analyzed and used to optimize the stent design before it is manufactured using EDM (Electric Discharge Machine) in the next research.

  17. Stent-assisted coil embolization for cavernous carotid artery aneurysms.

    Science.gov (United States)

    Kono, Kenichi; Shintani, Aki; Okada, Hideo; Tanaka, Yuko; Terada, Tomoaki

    2014-01-01

    Internal carotid artery (ICA) occlusion with or without a bypass surgery is the traditional treatment for cavernous sinus (CS) aneurysms with cranial nerve (CN) dysfunction. Coil embolization without stents frequently requires retreatment because of the large size of CS aneurysms. We report the mid-term results of six unruptured CS aneurysms treated with stent-assisted coil embolization (SACE). The mean age of the patients was 72 years. The mean size of the aneurysms was 19.8 mm (range: 13-26 mm). Before treatment, four patients presented with CN dysfunction and two patients had no symptoms. SACE was performed under local or general anesthesia in three patients each. Mean packing density was 29.1% and tight packing was achieved. There were no neurological complications. CN dysfunction was cured in three patients (75%) and partly resolved in one patient (25%). Transient new CN dysfunction was observed in two patients (33%). Clinical and imaging follow-up ranged from 6 to 26 months (median: 16 months). Recanalization was observed in three patients (50%; neck remnant in two patients and dome filling in one patient), but no retreatment has yet been required. No recurrence of CN dysfunction has occurred yet. In summary, SACE increases packing density and may reduce requirement of retreatment with an acceptable cure rate of CN dysfunction. SACE may be a superior treatment for coiling without stents and be an alternative treatment of ICA occlusion for selected patients, such as older patients and those who require a high-flow bypass surgery or cannot receive general anesthesia.

  18. Collapse of the balloon-expandable stent in the common iliac artery due to minor external compression in a lean patient

    International Nuclear Information System (INIS)

    Park, Sung Eun; Choi, Ho Cheol; Choi, Dae Seob; Lee, Sang Min; Lee, Jung Eun; Cho, Su Beom; Ahn, Jong Hwa

    2017-01-01

    A 60-year-old lean man with claudication due to severe stenosis of the right common iliac artery (CIA) underwent balloon-expandable stent deployment. Nineteen months later, claudication and lower limb ischemia in the patient recurred after minor external pressure and computed tomography indicated collapse of the right CIA stent. We performed balloon angioplasty again and self-expandable stent deployment was performed, and the patient's symptoms were relieved. We suggest that the CIA in a lean person could be susceptible to external pressure

  19. A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial.

    Science.gov (United States)

    de Winter, Robbert J; Katagiri, Yuki; Asano, Taku; Milewski, Krzysztof P; Lurz, Philipp; Buszman, Pawel; Jessurun, Gillian A J; Koch, Karel T; Troquay, Roland P T; Hamer, Bas J B; Ophuis, Ton Oude; Wöhrle, Jochen; Wyderka, Rafał; Cayla, Guillaume; Hofma, Sjoerd H; Levesque, Sébastien; Żurakowski, Aleksander; Fischer, Dieter; Kośmider, Maciej; Goube, Pascal; Arkenbout, E Karin; Noutsias, Michel; Ferrari, Markus W; Onuma, Yoshinobu; Wijns, William; Serruys, Patrick W

    2018-02-03

    MiStent is a drug-eluting stent with a fully absorbable polymer coating containing and embedding a microcrystalline form of sirolimus into the vessel wall. It was developed to overcome the limitation of current durable polymer drug-eluting stents eluting amorphous sirolimus. The clinical effect of MiStent sirolimus-eluting stent compared with a durable polymer drug-eluting stents has not been investigated in a large randomised trial in an all-comer population. We did a randomised, single-blind, multicentre, phase 3 study (DESSOLVE III) at 20 hospitals in Germany, France, Netherlands, and Poland. Eligible participants were any patients aged at least 18 years who underwent percutaneous coronary intervention in a lesion and had a reference vessel diameter of 2·50-3·75 mm. We randomly assigned patients (1:1) to implantation of either a sirolimus-eluting bioresorbable polymer stent (MiStent) or an everolimus-eluting durable polymer stent (Xience). Randomisation was done by local investigators via web-based software with random blocks according to centre. The primary endpoint was a non-inferiority comparison of a device-oriented composite endpoint (DOCE)-cardiac death, target-vessel myocardial infarction, or clinically indicated target lesion revascularisation-between the groups at 12 months after the procedure assessed by intention-to-treat. A margin of 4·0% was defined for non-inferiority of the MiStent group compared with the Xience group. All participants were included in the safety analyses. This trial is registered with ClinicalTrials.gov, number NCT02385279. Between March 20, and Dec 3, 2015, we randomly assigned 1398 patients with 2030 lesions; 703 patients with 1037 lesions were assigned to MiStent, of whom 697 received the index procedure, and 695 patients with 993 lesions were asssigned to Xience, of whom 690 received the index procedure. At 12 months, the primary endpoint had occurred in 40 patients (5·8%) in the sirolimus-eluting stent group and in 45

  20. Randomized controlled study of excimer laser atherectomy for treatment of femoropopliteal in-stent restenosis: initial results from the EXCITE ISR trial (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis).

    Science.gov (United States)

    Dippel, Eric J; Makam, Prakash; Kovach, Richard; George, Jon C; Patlola, Raghotham; Metzger, D Christopher; Mena-Hurtado, Carlos; Beasley, Robert; Soukas, Peter; Colon-Hernandez, Pedro J; Stark, Matthew A; Walker, Craig

    2015-01-01

    The purpose of this study was to evaluate the safety and efficacy of excimer laser atherectomy (ELA) with adjunctive percutaneous transluminal angioplasty (PTA) versus PTA alone for treating patients with chronic peripheral artery disease with femoropopliteal bare nitinol in-stent restenosis (ISR). Femoropopliteal stenting has shown superiority to PTA for lifestyle-limiting claudication and critical limb ischemia, although treating post-stenting artery reobstruction, or ISR, remains challenging. The multicenter, prospective, randomized, controlled EXCITE ISR (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis) trial was conducted across 40 U.S. centers. Patients with Rutherford Class 1 to 4 and lesions of target lesion length ≥4 cm, vessel diameter 5 to 7 mm were enrolled and randomly divided into ELA + PTA and PTA groups by a 2:1 ratio. The primary efficacy endpoint was target lesion revascularization (TLR) at 6-month follow up. The primary safety endpoint was major adverse event (death, amputation, or TLR) at 30 days post-procedure. Study enrollment was stopped at 250 patients due to early efficacy demonstrated at a prospectively-specified interim analysis. A total of 169 ELA + PTA subjects (62.7% male; mean age 68.5 ± 9.8 years) and 81 PTA patients (61.7% male; mean age 67.8 ± 10.3 years) were enrolled. Mean lesion length was 19.6 ± 12.0 cm versus 19.3 ± 11.9 cm, and 30.5% versus 36.8% of patients exhibited total occlusion. ELA + PTA subjects demonstrated superior procedural success (93.5% vs. 82.7%; p = 0.01) with significantly fewer procedural complications. ELA + PTA and PTA subject 6-month freedom from TLR was 73.5% versus 51.8% (p < 0.005), and 30-day major adverse event rates were 5.8% versus 20.5% (p < 0.001), respectively. ELA + PTA was associated with a 52% reduction in TLR (hazard ratio: 0.48; 95% confidence interval: 0.31 to 0.74). The EXCITE ISR trial is the first large, prospective, randomized study

  1. Reversal of end-stage renal disease after aortic dissection using renal artery stent: a case report

    Directory of Open Access Journals (Sweden)

    Parikh Chirag R

    2004-05-01

    Full Text Available Abstract Background Medical management is the conventional treatment for Stanford Type B aortic dissections as surgery is associated with significant morbidity and mortality. The advent of endovascular interventional techniques has revived interest in treating end-organ complications of Type B aortic dissection. We describe a patient who benefited from endovascular repair of renal artery stenosis caused by a dissection flap, which resulted in reversal of his end-stage renal disease (ESRD. Case presentation A 69 y/o male with a Type B aortic dissection diagnosed two months earlier was found to have a serum creatinine of 15.2 mg/dL (1343.7 μmol/L on routine visit to his primary care physician. An MRA demonstrated a rightward spiraling aortic dissection flap involving the origins of the celiac artery, superior mesenteric artery, and both renal arteries. The right renal artery arose from the false lumen with lack of blood flow to the right kidney. The left renal artery arose from the true lumen, but an intimal dissection flap appeared to be causing an intermittent stenosis of the left renal artery with compromised blood flow to the left kidney. Endovascular reconstruction with of the left renal artery with stent placement was performed. Hemodialysis was successfully discontinued six weeks after stent placement. Conclusion Percutaneous intervention provides a promising alternative for patients with Type B aortic dissections when medical treatment will not improve the likelihood of meaningful recovery and surgery entails too great a risk. Nephrologists should therefore be aggressive in the workup of ischemic renal failure associated with aortic dissection as percutaneous intervention may reverse the effects of renal failure in this population.

  2. Endovascular treatment of acutely ruptured, wide-necked anterior communicating artery aneurysms using the Enterprise stent.

    Science.gov (United States)

    Huang, Qing-Hai; Wu, Yong-Fa; Shen, Jie; Hong, Bo; Yang, Peng-Fei; Xu, Yi; Zhao, Wen-Yuan; Liu, Jian-Min

    2013-02-01

    The treatment of anterior communicating artery (AcomA) wide-necked aneurysms with the Enterprise stent (Codman, Miami Lakes, FL, USA) has not been commonly described, due to the complexity of the vascular anatomy and the small vessels of the AcomA complex. To evaluate the feasibility, effectiveness and safety of Enterprise stent placement in AcomA aneurysms, we performed this retrospective study. Between November 2008 and December 2010, 27 wide-necked AcomA ruptured aneurysms were treated within 72 hours of ictus with the Enterprise stent. Data collected and analyzed were: demographic data, morphologic features of the aneurysm, treatment results and follow-up results. Twenty-nine Enterprise stents were successfully deployed in all 27 aneurysms, including Y-configuration stent deployment in two patients. The initial embolization degrees were Raymond class I in 20 patients, class II in five and class III in the other two. The angiographic follow-up of 21 patients (mean, 8.4 months) showed that all aneurysms remained stable or improved; there was no in-stent stenosis, recurrence or retreatment. The clinical follow-up of 26 patients (mean, 12.6 months) showed that 23 patients displayed no symptoms and no or mild disability; three patients remained with severe or moderately severe disability. The Enterprise stent is feasible and safe for endovascular embolization of wide-necked AcomA ruptured aneurysms. Further follow up is needed to assess the long-term efficacy of Enterprise stent placement in AcomA. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT

    International Nuclear Information System (INIS)

    Steen, Henning; Andre, Florian; Korosoglou, Grigorios; Mueller, Dirk; Hosch, Waldemar; Kauczor, Hans-Ulrich; Giannitsis, Evangelos; Katus, Hugo A.

    2011-01-01

    Objective: We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. Background: Early identification of in-stent restenosis (ISR) is important to avoid recurrent ischemia and prevent acute myocardial infarction (AMI). Since angiography has the disadvantage of high costs and its invasiveness, MDCT could be a convenient and safe non-invasive alternative for detection of ISR. Material and methods: Percentages of in-stent lumen diameter and in-stent signal attenuation (measured as contrast-to-noise ratio (CNR)) of 56 coronary stents (group A ≤2.5 mm; group B = 2.75-3.0 mm; group C = 3.5-4.0 mm) were evaluated in a coronary vessel in vitro phantom (iodine-filled plastic tubes) employing four different reconstruction algorithms (XCD, CC, CD, XCB) on a novel 256-MDCT (Philips-iCT, collimation = 128 mm x 0.625 mm; rotation time = 270 ms; tube current = 800 mA s with 120 kV). Analysis was conducted with the semi-automatical full-width-at-half-maximum (FWHM) method. P-values 60% for group C stents was significantly larger and CNR was significantly lower (both p 3.0 mm when analysed with cardio-dedicated sharp kernels, although clinical studies corroborating this claim should be performed. However, stents ≤3.0 mm reconstructed by soft kernels revealed insufficient in-stent lumen visualisation and should not be used in clinical practice. Further improvements in spatial and temporal image resolution as well as reductions of radiation exposure and image noise have to be accomplished for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen.

  4. Implante de stent dentro de stent recém-implantado em ponte de veia safena para otimização do resultado angiográfico Stenting a stent in saphenous vein graft to optimize the angiographic result

    Directory of Open Access Journals (Sweden)

    Antonio Esteves Fº

    1998-03-01

    Full Text Available Mulher de 60 anos, com angina progressiva e revascularização do miocárdio, há oito anos, com ponte de veia safena para coronária direita e anastomose de artéria mamaria esquerda para artéria descendente anterior. Submetida a implante de stent Gianturco-Roubin II em terço proximal da ponte de veia safena para artéria coronária direita, com resultado insatisfatório pela persistência de lesão residual, provavelmente, decorrente de prolapso para dentro da luz de material aterosclerótico através dos coils. Foi implantado outro stent (Palmaz-Schatz biliar dentro do stent GRII com sucesso e ótimo resultado angiográfico. Um 2º stent Palmaz-Schatz biliar foi implantado em lesão distal no corpo da ponte, ultrapassando os dois stents, anteriormente implantados, com sucesso. Em algumas situações, implante de stent dentro de outro stent é recurso útil para otimização de resultado angiográfico do implante de um stent.A 60 year-old woman with progressive angina who had been submitted to saphenous bypass-graft to right coronary artery and a left mammary artery graft to anterior descending artery eight years previously, underwent implantation of a Gianturco Roubin II stent in the proximal third of the saphenous vein graft. The result was suboptimal by persistence of a residual stenosis probably due to prolapse of atherosclerotic material through the coil spaces. Another stent (Palmaz-Schatz biliar stent was implanted at the previously stented site with no residual stenosis. Another Palmaz-Schatz biliar stent was successfully implanted in the distal body of the graft to treat another lesion (passing through the previously stents without difficulty. Stenting a stent, in selected situations, is a useful tool to optimize the angiographic result of stent implantation.

  5. Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial.

    Science.gov (United States)

    Ali, Ziad A; Maehara, Akiko; Généreux, Philippe; Shlofmitz, Richard A; Fabbiocchi, Franco; Nazif, Tamim M; Guagliumi, Giulio; Meraj, Perwaiz M; Alfonso, Fernando; Samady, Habib; Akasaka, Takashi; Carlson, Eric B; Leesar, Massoud A; Matsumura, Mitsuaki; Ozan, Melek Ozgu; Mintz, Gary S; Ben-Yehuda, Ori; Stone, Gregg W

    2016-11-26

    Percutaneous coronary intervention (PCI) is most commonly guided by angiography alone. Intravascular ultrasound (IVUS) guidance has been shown to reduce major adverse cardiovascular events (MACE) after PCI, principally by resulting in a larger postprocedure lumen than with angiographic guidance. Optical coherence tomography (OCT) provides higher resolution imaging than does IVUS, although findings from some studies suggest that it might lead to smaller luminal diameters after stent implantation. We sought to establish whether or not a novel OCT-based stent sizing strategy would result in a minimum stent area similar to or better than that achieved with IVUS guidance and better than that achieved with angiography guidance alone. In this randomised controlled trial, we recruited patients aged 18 years or older undergoing PCI from 29 hospitals in eight countries. Eligible patients had one or more target lesions located in a native coronary artery with a visually estimated reference vessel diameter of 2·25-3·50 mm and a length of less than 40 mm. We excluded patients with left main or ostial right coronary artery stenoses, bypass graft stenoses, chronic total occlusions, planned two-stent bifurcations, and in-stent restenosis. Participants were randomly assigned (1:1:1; with use of an interactive web-based system in block sizes of three, stratified by site) to OCT guidance, IVUS guidance, or angiography-guided stent implantation. We did OCT-guided PCI using a specific protocol to establish stent length, diameter, and expansion according to reference segment external elastic lamina measurements. All patients underwent final OCT imaging (operators in the IVUS and angiography groups were masked to the OCT images). The primary efficacy endpoint was post-PCI minimum stent area, measured by OCT at a masked independent core laboratory at completion of enrolment, in all randomly allocated participants who had primary outcome data. The primary safety endpoint was procedural

  6. Enterprise stent for the treatment of symptomatic intracranial atherosclerotic stenosis: an initial experience of 44 patients.

    Science.gov (United States)

    Feng, Zhengzhe; Duan, Guoli; Zhang, Ping; Chen, Lei; Xu, Yi; Hong, Bo; Zhao, Wenyuan; Liu, Jianmin; Huang, Qinghai

    2015-10-08

    Wingspan stenting for the treatment of complex intracranial atherosclerotic stenosis (ICAS), i.e., that involving tortuous vascular pathways, long (>15 mm) lesions or arterial bifurcations, has a relatively high risk of complications. This retrospective study assessed the safety and efficacy of undersized balloon angioplasty followed by deployment of the more flexible Enterprise stent for the treatment of complex symptomatic ICAS. Forty-four patients on combined antiplatelet therapy and intensive risk factor management and a symptomatic 70-99% stenosis of a major intracranial artery in complex settings that was treated with balloon angioplasty and Enterprise stent deployment between July 2009 and August 2013 were enrolled. Primary outcome was occurrence of ischemic or hemorrhagic stroke or death within 30 days after intervention. Secondary outcomes included procedural success (defined as achievement of 50% in-stent restenosis after mean 22 months follow-up. In this retrospective, single-center experience, undersized balloon angioplasty followed by Enterprise stent deployment appears technically feasible with a relatively low rate of complications for the treatment of complex symptomatic ICAS. Prospective, multicenter, randomized controlled trials against optimal medical management are warranted.

  7. Endovascular stent graft for treatment of complicated spontaneous dissection of celiac artery: Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Diagnostic Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Hwan [Dept. of Diagnostic Radiology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2013-06-15

    We report 2 cases of complicated spontaneous dissection of the celiac artery, which were successfully treated by a stent graft. The first patient was a 47-year-old man who presented with acute abdominal pain. CT scan showed ruptured saccular aneurysm with surrounding retroperitoneal hematoma. The second patient was a 57-year-old man with progressive dissecting aneurysm. Endovascular stent graft was placed in the celiac trunk to control bleeding, and to prevent rupture in each patient. Follow-up CT scans showed complete obliteration of a dissecting aneurysm.

  8. Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents (BIONYX) : Rationale and design of the randomized TWENTE IV multicenter trial

    NARCIS (Netherlands)

    van der Heijden, Liefke C.; Kok, Marlies M.; Zocca, Paolo; Jessurun, Gillian A.J.; Schotborgh, Carl E.; Roguin, Ariel; Benit, Edouard; Aminian, Adel; Danse, Peter W.; Löwik, Marije M.; Linssen, Gerard C.M.; van der Palen, Job; Doggen, Carine J.M.; von Birgelen, Clemens

    2018-01-01

    Aim: The aim was to compare in a noninferiority trial the efficacy and safety of 2 contemporary drug-eluting stents (DESs): a novel, durable polymer-coated stent versus an established bioabsorbable polymer-coated stent. Methods and results: The BIONYX trial (ClinicalTrials.gov-no.NCT02508714) is an

  9. An experimental study on expandable endovascular metallic stents in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Kim, Hak Nam [Chonbuk National University College of Medicine, Chonju (Korea, Republic of)

    1990-12-15

    We constructed an expandable endovascular metallic stent in the same way as Giamturco did. Experiments were made to test the ability of these stents to be used in the vessels. A total of 20 stents were passed through a 8.5 French teflon sheath into the normal abdominal aorta. IVC, and iliac artery of four adult dogs for 4 weeks to 12 weeks; 8 stents (10 mm in diameter fully expanded and 20 mm in length) in the abnormal aorta, 7 stents (12 mm/20 mm) in the IVC, and 5 stents (8 mm/20 mm) in the iliac artery. All but two stents showed no migration, and one complete occlusion occurred in right iliac artery of a dog. Histologically, stents wires were covered by neo-intimal proliferation. The side branches of the main vessels remained patent, even stent wires across their orifices. These metallic stents may be used as an endovascular graft material in the nonsurgical treatment of several forms of vascular disease.

  10. Dutch iliac stent trial : Long-term results in patients randomized for primary or selective stent placement

    NARCIS (Netherlands)

    Klein, W.M.; van der Graaf, Y.; Seegers, J.; Spithoven, J.H.; Buskens, E.; van Baal, J.G.; Buth, J.; Moll, F.L.; Overtoom, T.T.C.; van Sambeek, M.R.H.M.; Mali, W.P.T.M.

    Purpose: To determine long-term results of the prospective Dutch Iliac Stent Trial. Materials and Methods: The study protocol was approved by local institutional review boards. All patients gave written informed consent. Two hundred seventy-nine patients (201 men, 78 women; mean age, 58 years) with

  11. [Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis].

    Science.gov (United States)

    Müller-Hülsbeck, S; Jahnke, T; Grimm, J; Behm, C; Hilbert, C; Frahm, C; Biederer, J; Brossmann, J; Heller, M

    2002-03-01

    To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink(TM) 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfemoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88 % plus minus 10 and 9 mm plus minus 5. Renal stent implantation was technically successful in all cases (100 %). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg plus minus 10 before to 1 mmHg plus minus 1.8 after the procedure. Remaining stenosis measured 0.7 % plus minus 4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n. s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p monorail-stend-balloon device a technically easy, secure and exact renal stent placement is guaranteed, patency rates are similar to those described in the current literature.

  12. A Mechanobiological model for damage-induced growth in arterial tissue with application to in-stent restenosis

    Science.gov (United States)

    Fereidoonnezhad, B.; Naghdabadi, R.; Sohrabpour, S.; Holzapfel, G. A.

    In-stent restenosis (ISR) is one of the main drawbacks of stent implementation which limits the long-term success of the procedure. Morphological changes occurring within the arterial wall due to stent-induced mechanical injury are a major cause for activation of vascular smooth muscle cells (VSMCs), and the subsequent development of ISR. Considering the theory of volumetric mass growth and adopting a multiplicative decomposition of the deformation gradient into an elastic part and a growth part, we present a mechanobiological model for ISR. An evolution equation is developed for mass growth of the neointima, in which the activation of VSMCs due to stent-induced damage (injury) and the proliferation rate of the activated cells are considered. By introducing the mass evolution into the mass balance equation, we obtain the evolution of the growth tensor over time. The model is implemented in a finite element code and the procedure of angioplasty is simulated, whereby the features of the proposed growth model are illustrated.

  13. Focal ischemia of the brain after neuroprotected carotid artery stenting.

    Science.gov (United States)

    Schlüter, Michael; Tübler, Thilo; Steffens, Johann C; Mathey, Detlef G; Schofer, Joachim

    2003-09-17

    This study sought to assess the incidence of cerebral ischemia in nonselected patients undergoing neuroprotected carotid angioplasty and stenting (CAS) without preceding multiple-vessel diagnostic angiography. Protection devices to prevent distal embolization during CAS are presently under clinical investigation. Diffusion-weighted magnetic resonance imaging (MRI) visualizes recent ischemia of the brain and may aid in assessing the efficacy of protection devices. Elective CAS was performed in 42 consecutive patients (15 female, 27 male; mean age, 67 +/- 9 years) using six different types of cerebral protection systems. All patients underwent MRI of the brain before and after a total of 44 interventions. Placement and retrieval of the devices and stent deployment was achieved in all procedures. New ischemic foci were seen on postinterventional MRI in 10 cases (22.7%). One patient had sustained a major stroke, whereas no adverse neurological sequelae were associated with the other nine procedures. In the latter, one to three foci (maximum area 43.0 mm(2)) were detected in cerebral regions subtended by the ipsilateral carotid artery in eight cases and by the contralateral carotid artery in one case. In the stroke patient, 12 ischemic foci (maximum area 84.5 mm(2)) were exclusively located in the contralateral hemisphere. Follow-up MRI at 4.1 months (median, n = 7) identified residuals of cerebral ischemia only in this patient. Neuroprotected CAS is associated in about 25% of cases with predominantly silent cerebral ischemia. Our findings suggest manipulation of endoluminal equipment in the supraaortic vessels to be a major risk factor for cerebral embolism during neuroprotected CAS.

  14. Collapse of the balloon-expandable stent in the common iliac artery due to minor external compression in a lean patient

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Eun; Choi, Ho Cheol; Choi, Dae Seob; Lee, Sang Min; Lee, Jung Eun [Gyeongsang National University School of Medicine and Gyeongsang National University Hospital, Jinju (Korea, Republic of); Cho, Su Beom; Ahn, Jong Hwa [Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon (Korea, Republic of)

    2017-08-15

    A 60-year-old lean man with claudication due to severe stenosis of the right common iliac artery (CIA) underwent balloon-expandable stent deployment. Nineteen months later, claudication and lower limb ischemia in the patient recurred after minor external pressure and computed tomography indicated collapse of the right CIA stent. We performed balloon angioplasty again and self-expandable stent deployment was performed, and the patient's symptoms were relieved. We suggest that the CIA in a lean person could be susceptible to external pressure.

  15. Wingspan stent system in the treatment of symptomatic intracranial atherosclerotic stenosis

    International Nuclear Information System (INIS)

    Li Tianxiao; Li Zhaoshuo; Wang Ziliang; Xue Jiangyu; Bai Weixing; Li Li; Zhai Shuiting; Feng Yingpu

    2010-01-01

    Objective: To assess the safety, feasibility, short- and mid-term efficacy of wingspan stent for treating patients with symptomatic intracranial artery stenosis. Methods: A total of 113 patients with severe symptomatic intracranial stenosis were enrolled and Gateway-wingspan stenting were performed on all patients. The technical success, the pre- and post-stenting stenosis, perioperative complications, clinical outcome and restenosis rates were recorded, and chi-square test was used for analysis of complication rate by comparing our results with the results of Warfarin-Aspirin Symptomatic Intracranial Disease (WASID) study and NIH multi-center Wingspan stenting trial. Results: The technical success rate was 99.1% (112/ 113). The mean pre and post-stent stenoses were (80.7±9.3)% and (27.7±9.7)% (χ 2 =9.397, P<0.05). The total complication rate was 4.4% (5/113) during the follow-up (mean 14.5 months, range 1-28 months), and the frequency of' restenosis was 12.5% (5/40) at 6 months. The primary endpoint events, ischemic stroke, and lesion-related ischemic stroke were lower in our study (4.5%, 3.5%, 3.5%) compared with the results of WASID trial (21.1%, 20.4%, 15.0%, P<0.05). For those with poor outcome in the three high-risk sub-groups which were with more than 70% stenosis, or last event from the treatment was less than 17 days, or NIHSS was above 1, a better outcome was observed in our group (4.5%, 4.7% and 2.0% in our study, 19.0%, 17.0% and 19.6% in previous study, P<0.05). The medium-term efficacy in this group (4.5%) significantly improved compared with NIH study (14.0%, P< 0.05). Conclusions: Wingspan stenting for symptomatic intracranial arterial stenosis is with good safety, feasibility and low perioperative stroke rate and mortality. The incidence of primary endpoint events and the ischemic events are lower than those of medication group, and the efficacy of stenting is significantly better than medication even in high-risk population. (authors)

  16. Lesion-Related Carotid Angioplasty and Stenting with Closed-Cell Design without Embolic Protection Devices in High-Risk Elderly Patients-Can This Concept Work Out? A Single Center Experience Focusing on Stent Design.

    Science.gov (United States)

    Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan

    2014-12-01

    To compare the performance differences of three carotid artery stents in high-risk elderly patients without embolic protection devices (EPDs) on the basis of stent design, procedure-related complications, conveniences in handling, in-stent restenosis, 30-day outcome, and long-term follow-up. A total of 101 symptomatic internal carotid stenoses of 94 patients were prospectively treated with stent-protected angioplasty to 94 patients. Three closed-cell stents, one of those being hybrid cell design, were chosen depending on vascular anatomy: curved vessel, lesion length > 1 cm: 64 Carotid Wallstent (Boston Scientific, Natick, MA); curved vessel, lesion length  1 cm: 16 Xact (Vascular Abbott, Santa Clara, CA). Comparisons of demographics, procedures, and outcomes were performed. The mean age of patients was 73.1 years (standard deviation [SD], ± 7.9; range, 58-87 years), 71% of the patients were older than 70 years and 20% were octogenarians. Male/female ratio was 3.1:1. About 13.9% (14/101) had contralateral internal carotid artery occlusion. Overall peri-interventional complication rate was 2.9% and 30-day mortality rate was 1%. During the long-term follow-up (34 months, range 1-59) no ipsilateral stroke was documented. Ten deaths (three after MI) were recognized. Two in-stent restenosis were detected (> 70% North American Symptomatic Carotid Endarterectomy Trial) during follow-up, one patient was detected with previous carotid endarterectomy. Especially, if individual anatomical variance is considered, lesion-related stent-protected carotid angioplasty with lesion-adapted closed-cell design is an effective, reliable, safe, and comprehensible treatment option in symptomatic patients. Even without EPDs, the rate of complications is low, when compared with symptomatic carotid artery stenosis described in the literature. In-stent restenosis seems to play no significant role in follow-up.

  17. Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.

    Science.gov (United States)

    Baron, Suzanne J; Lei, Yang; Chinnakondepalli, Khaja; Vilain, Katherine; Magnuson, Elizabeth A; Kereiakes, Dean J; Ellis, Stephen G; Stone, Gregg W; Cohen, David J

    2017-04-24

    The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the Xience stent with respect to target lesion failure at 1 year. Whether health care costs differ between the Absorb scaffold and the Xience stent is unknown. We performed a prospective health economic study alongside the ABSORB III trial, in which patients undergoing percutaneous coronary intervention for stable or unstable angina were randomized to receive the Absorb scaffold (n = 1,322) or Xience stent (n = 686). Resource use data were collected through 1 year of follow-up. Costs were assessed using resource-based accounting (for procedures), MedPAR data (for other index hospitalization costs), and Medicare reimbursements (for follow-up costs and physician fees). Initial procedural costs were higher with the Absorb scaffold than the Xience stent ($6,316 ± 1,892 vs. $6,103 ± 1,895; p = 0.02), driven mainly by greater balloon catheter use and the higher cost of the scaffold in the Absorb group. Nonetheless, index hospitalization costs ($15,035 ± 2,992 for Absorb vs. $14,903 ± 3,449 for Xience; p = 0.37) and total 1-year costs ($17,848 ± 6,110 for Absorb vs. $17,498 ± 7,411 for Xience; p = 0.29) were similar between the 2 groups. Although initial procedural costs were higher with the Absorb scaffold, there were no differences in total 1-year health care costs between the 2 cohorts. Longer term follow-up is needed to determine whether meaningful cost savings emerge after scaffold resorption. (A Clinical Evaluation of Absorb™ BVS, the Everolimus-Eluting Bioresorbable Vascular Scaffold in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT01751906). Copyright © 2017

  18. Outcomes of coronary artery bypass grafting versus percutaneous coronary intervention with drug-eluting stents for patients with multivessel coronary artery disease.

    Science.gov (United States)

    Javaid, Aamir; Steinberg, Daniel H; Buch, Ashesh N; Corso, Paul J; Boyce, Steven W; Pinto Slottow, Tina L; Roy, Probal K; Hill, Peter; Okabe, Teruo; Torguson, Rebecca; Smith, Kimberly A; Xue, Zhenyi; Gevorkian, Natalie; Suddath, William O; Kent, Kenneth M; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2007-09-11

    Advances in coronary artery bypass grafting (CABG) surgery and percutaneous coronary intervention (PCI) with drug-eluting stents have dramatically improved results of these procedures. The optimal treatment for patients with multivessel coronary artery disease is uncertain given the lack of prospective, randomized data reflecting current practice. This study represents a "real-world" evaluation of current technology in the treatment of multivessel coronary artery disease. A total of 1680 patients undergoing revascularization for multivessel coronary artery disease were identified. Of these, 1080 patients were treated for 2-vessel disease (196 CABG and 884 PCI) and 600 for 3-vessel disease (505 CABG and 95 PCI). One-year mortality, cerebrovascular events, Q-wave myocardial infarction, target vessel failure, and composite major adverse cardiovascular and cerebrovascular events were compared between the CABG and PCI cohorts. Outcomes were adjusted for baseline covariates and reported as hazard ratios. The unadjusted major adverse cardiovascular and cerebrovascular event rate was reduced with CABG for patients with 2-vessel disease (9.7% CABG versus 21.2% PCI; P<0.001) and 3-vessel disease (10.8% CABG versus 28.4% PCI; P<0.001). Adjusted outcomes showed increased major adverse cardiovascular and cerebrovascular event with PCI for patients with 2-vessel (hazard ratio 2.29; 95% CI 1.39 to 3.76; P=0.01) and 3-vessel disease (hazard ratio 2.90; 95% CI 1.76 to 4.78; P<0.001). Adjusted outcomes for the nondiabetic subpopulation demonstrated equivalent major adverse cardiovascular and cerebrovascular event with PCI for 2-vessel (hazard ratio 1.77; 95% CI 0.96 to 3.25; P=0.07) and 3-vessel disease (hazard ratio 1.70; 95% CI 0.77 to 3.61; P=0.19). Compared with PCI with drug-eluting stents, CABG resulted in improved major adverse cardiovascular and cerebrovascular event in patients with 2- and 3-vessel coronary artery disease, primarily in those with underlying diabetes

  19. Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

    International Nuclear Information System (INIS)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis; Padayachee, Soundrie; Karunanithy, Narayan; Ahmed, Irfan; Zayed, Hany; Katsanos, Konstantinos

    2015-01-01

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery

  20. Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Padayachee, Soundrie [King’s Health Partners, Department of Ultrasonic Angiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Karunanithy, Narayan; Ahmed, Irfan [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Zayed, Hany [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: konstantinos.katsanos@gstt.nhs.uk, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery.

  1. Análise morfométrica da carótida de suínos submetidos a angioplastia com ou sem implante de stent de cromo-cobalto Morphometric analysis of swine carotid artery angioplasty with or without cobalt-chromium stent implantation

    Directory of Open Access Journals (Sweden)

    João Luiz de Lara Elesbão

    2010-06-01

    Full Text Available Contexto: A hiperplasia intimal é a reação tardia mais comum decorrente da angioplastia. O uso de stents de cromo-cobalto é bem estudado na circulação coronariana, porém não há muitos estudos que abordem o uso desses stents nas circulações carotídea e periférica. Objetivo: Analisar mediante morfometria a reação intimal presente na artéria carótida de suínos submetidos a angioplastia isoladamente e a angioplastia seguida de implante de stent de cromo-cobalto. Materiais e métodos: Em oito suínos, foi realizada angioplastia da artéria carótida comum direita e angioplastia seguida de implante de um stent de cromo-cobalto na artéria carótida comum esquerda. Após 4 semanas, os animais foram submetidos a eutanásia para a retirada de amostras de tecido arterial e preparo de lâminas histológicas. As imagens das lâminas foram digitalizadas e analisadas por programa de morfometria digital. A análise estatística foi realizada através da média e desvio padrão das áreas em cada grupo, utilizando-se o Teste t de Student. O valor de p Background: Intimal hyperplasia is the most common delayed response to angioplasty. The use of cobalt-chromium stents is well studied in the coronary circulation; however, there are few studies on their use in the carotid and peripheral circulation. Objective: To analyze the intimal reaction in a swine carotid artery undergoing simple angioplasty and angioplasty followed by implantation of cobalt-chromium stent. Materials and methods: We carried out angioplasty in the right common carotid artery and angioplasty with cobalt-chromium stent in the left common carotid artery in eight swine. Four weeks later, all animals were sacrificed for arterial tissue sampling and preparation of histological slides. Slide images were scanned and analyzed using a digital morphometry program. Statistical analysis was performed by mean values and standard deviations of the areas in each group, using the Student's t

  2. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Cannavale, Alessandro; Gazzetti, Marianna; Fantozzi, Cristiano; Taurino, Maurizio; Speziale, Francesco

    2013-01-01

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient’s clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  3. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Cannavale, Alessandro [University of Rome ' Sapienza,' , Department of Radiological Sciences, Vascular and Interventional Radiology Unit (Italy); Gazzetti, Marianna [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy); Fantozzi, Cristiano; Taurino, Maurizio [University of Rome ' Sapienza,' , Department of Vascular Surgery (Italy); Speziale, Francesco [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy)

    2013-02-15

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient's clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  4. Cost effectiveness of drug eluting coronary artery stenting in a UK setting: cost-utility study.

    Science.gov (United States)

    Bagust, A; Grayson, A D; Palmer, N D; Perry, R A; Walley, T

    2006-01-01

    To assess the cost effectiveness of drug eluting stents (DES) compared with conventional stents for treatment of symptomatic coronary artery disease in the UK. Cost-utility analysis of audit based patient subgroups by means of a simple economic model. Tertiary care. 12 month audit data for 2884 patients receiving percutaneous coronary intervention with stenting at the Cardiothoracic Centre Liverpool between January 2000 and December 2002. Risk of repeat revascularisation within 12 months of index procedure and reduction in risk from use of DES. Economic modelling was used to estimate the cost-utility ratio and threshold price premium. Four factors were identified for patients undergoing elective surgery (n = 1951) and two for non-elective surgery (n = 933) to predict risk of repeat revascularisation within 12 months. Most patients fell within the subgroup with lowest risk (57% of the elective surgery group with 5.6% risk and 91% of the non-elective surgery group with 9.9% risk). Modelled cost-utility ratios were acceptable for only one group of high risk patients undergoing non-elective surgery (only one patient in audit data). Restricting the number of DES for each patient improved results marginally: 4% of stents could then be drug eluting on economic grounds. The threshold price premium justifying 90% substitution of conventional stents was estimated to be 112 pound sterling (212 USD, 162 pound sterling) (sirolimus stents) or 89 pound sterling (167 USD, 130 pound sterling) (paclitaxel stents). At current UK prices, DES are not cost effective compared with conventional stents except for a small minority of patients. Although the technology is clearly effective, general substitution is not justified unless the price premium falls substantially.

  5. Outcomes of the single-stent versus kissing-stents technique in asymmetric complex aortoiliac bifurcation lesions.

    Science.gov (United States)

    Suh, Yongsung; Ko, Young-Guk; Shin, Dong-Ho; Kim, Jung-Sun; Kim, Byeong-Keuk; Choi, Donghoon; Hong, Myeong-Ki; Jang, Yangsoo

    2015-07-01

    This study investigated the outcomes of single-stent vs kissing-stents techniques in asymmetric complex aortoiliac bifurcation (ACAB) lesions. We retrospectively investigated 80 consecutive patients (69 males, 66.6 ± 8.7 years) treated with a single stent and 30 patients (26 males, 67.1 ± 7.7 years) treated with kissing stents for ACAB between January 2005 and December 2012 from a single-center cohort. A ACAB lesion was defined as a symptomatic unilateral common iliac artery stenosis (>50%) combined with intermediate stenosis (30%-50%) in the contralateral common iliac artery ostium. The primary end point was the primary patency of the ACAB. The baseline clinical characteristics did not differ significantly between the single-stent and the kissing-stents group. Technical success was achieved in all patients. The single-stent group required fewer stents (1.3 ± 0.5 vs 2.3 ± 0.8; P stent group (3%) required bailout kissing stents because of plaque shift to the contralateral side. The major complication rates were 8% in single-stent vs 13% in the kissing-stent group, which was similar (P = .399). At 3 years, the single-stent and kissing-stents group had similar rates of primary patency (89% vs 87%; P = .916) and target lesion revascularization-free survival (93% vs 87%; P = .462). The single-stent technique in ACAB was safe and showed midterm outcomes comparable with those of kissing stents. Considering the benefits, such as fewer stents, less bilateral femoral access, and the availability of contralateral access for future intervention, the single-stent technique may be an advantageous treatment option in ACAB. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  6. Patient- and lesion-tailored algorithm of endovascular treatment for arterial occlusive disease of extracranial arteries supplying the brain: safety of the treatment at 30-day follow-up

    Directory of Open Access Journals (Sweden)

    Paweł Latacz

    2017-03-01

    Full Text Available Introduction: Although surgical endarterectomy remains the treatment of choice for carotid artery stenosis, stenting plays an important role as an alternative treatment modality, especially in high-risk patients. The actual safety profile associated with stenting procedures is probably better than that reported by randomized controlled trials. Aim : To assess the safety of stent implantations in extracranial arteries supplying the brain, and also to identify risk factors associated with this procedure. Material and methods: This was a post hoc analysis, with 30-day follow-up. We analyzed the results of treatment of 372 patients who underwent 408 procedures, 197 such procedures in asymptomatic, and 211 in symptomatic individuals. Stenting procedures were performed using a technique and armamentarium which were tailored to the type and anatomy of lesions. Results : There were 6 (1.5% strokes, including 2 (0.5% major strokes, 1 ipsi- and 1 contralateral, and 4 (1.0% minor strokes. In asymptomatic patients there was 1 (0.3% minor stroke. Transient ischemic attacks occurred in 5 (1.2% patients. There were 2 (0.5% non-STEMI myocardial infarctions and 2 (0.5% non-stroke related fatalities. Risk factors of these adverse events were diabetes mellitus, lesions localized in a tortuous segment of the artery, embolic material in the filter and bilateral stenoses of carotid arteries. Additional risk factors in asymptomatic patients were renal impairment and advanced coronary artery disease; and in symptomatic patients, grade 3 arterial hypertension, dislipidemia, cigarette smoking and lesions requiring predilatation. Conclusions : Stenting procedures of extracranial arteries supplying the brain, which are tailored to the type and anatomy of lesions, seem to be relatively safe.

  7. Patient- and lesion-tailored algorithm of endovascular treatment for arterial occlusive disease of extracranial arteries supplying the brain: safety of the treatment at 30-day follow-up

    Science.gov (United States)

    Simka, Marian; Brzegowy, Paweł; Janas, Piotr; Kazibudzki, Marek; Pieniążek, Piotr; Ochała, Andrzej; Popiela, Tadeusz; Mrowiecki, Tomasz

    2017-01-01

    Introduction Although surgical endarterectomy remains the treatment of choice for carotid artery stenosis, stenting plays an important role as an alternative treatment modality, especially in high-risk patients. The actual safety profile associated with stenting procedures is probably better than that reported by randomized controlled trials. Aim To assess the safety of stent implantations in extracranial arteries supplying the brain, and also to identify risk factors associated with this procedure. Material and methods This was a post hoc analysis, with 30-day follow-up. We analyzed the results of treatment of 372 patients who underwent 408 procedures, 197 such procedures in asymptomatic, and 211 in symptomatic individuals. Stenting procedures were performed using a technique and armamentarium which were tailored to the type and anatomy of lesions. Results There were 6 (1.5%) strokes, including 2 (0.5%) major strokes, 1 ipsi- and 1 contralateral, and 4 (1.0%) minor strokes. In asymptomatic patients there was 1 (0.3%) minor stroke. Transient ischemic attacks occurred in 5 (1.2%) patients. There were 2 (0.5%) non-STEMI myocardial infarctions and 2 (0.5%) non-stroke related fatalities. Risk factors of these adverse events were diabetes mellitus, lesions localized in a tortuous segment of the artery, embolic material in the filter and bilateral stenoses of carotid arteries. Additional risk factors in asymptomatic patients were renal impairment and advanced coronary artery disease; and in symptomatic patients, grade 3 arterial hypertension, dislipidemia, cigarette smoking and lesions requiring predilatation. Conclusions Stenting procedures of extracranial arteries supplying the brain, which are tailored to the type and anatomy of lesions, seem to be relatively safe. PMID:28344618

  8. Self-made Palmaz stent: an experimental swine model study

    International Nuclear Information System (INIS)

    He Shicheng; Teng Gaojun; Guo Jinhe; Fang Wen

    2000-01-01

    Objective: To investigate the histologic changes and physicochemical stability of self-made Palmaz stent placed in swine arteries. Methods: The self-made Palmaz stent was made of 316L stainless steel wire. Nine stents were respectively placed within internal carotid, renal and iliac arteries of six pigs. Pigs were euthanized at intervals of 0.5, 1 and 3 months respectively and angiography were performed. Immediately followed by light and electro scanning microscopy for the stent zones. Results: All stents were successfully implanted in the target arteries and were patent shown in the angiographic examination immediately after the stent placement. Eight stents (8/9) remained patent at the time before euthanasia. No migration of stent were shown in the follow-up angiography. Light and electron scanning microscopy showed that the surface of the stents was covered by a thin layer of endothelial cells 2 weeks after the procedure and completely covered after 4 weeks. No inflammation occurred. Conclusions: The self-made Palmaz stent has good physicochemical stability and histocompatibility with easy placement, rather long term patency, histopathologic stability and thus the promising for clinical application

  9. Experimental Evaluation of a New Single Wire Stainless Steel Fishscale Coronary Stent (Freedomª).

    Science.gov (United States)

    Wang; Verbeken; Mukherjee; Zhou; De Scheerder IK

    1996-10-01

    Recent randomized clinical trials revealed a significant reduction in angiographic restenosis rates when adjunctive stenting was performed after conventional coronary balloon angioplasty. Current approved coronary stents are however hampered by their rigidity, limiting their trackability in tortuous vessels and furthermore, needing high pressure deployment for optimal vessel apposition. New coronary stents are currently under development, using more biocompatible metal alloys and/or designs which better align to the vessel wall at moderate deployment pressures. We evaluated the safety, efficacy, angiographic and histological effect of a new stainless steel fishscale designed stent (Freedomª, Global Therapeutics, Co., USA) in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 20 pigs. Control angiograms at 6 weeks follow-up demonstrated patent vessels and morphologic evaluation showed only a mild fibromuscular neointimal response resulting in an area stenosis of 28.7 +/- 0.18% and a mean neointimal hyperplasia of 0.18 +/- 0.25 mm. Comparison with the Palmaz-Schatzª coronary stent in a porcine peripheral artery model demonstrated similar quantitative angiographic and morphologic vessel analysis results. Also the morphometric data were comparable. Area stenosis: Palmaz-Schatz: 37 +/- 0.24%, Freedom: 21 +/- 0.14%, p = 0.07. Mean neointimal hyperplasia: Palmaz-Schatz: 0.33 +/- 0.24 mm, Freedom: 0.18 +/- 0.08 mm, p = 0.08. CONCLUSION: Freedom coronary stent implantation in a porcine model resulted in a high procedural success without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six weeks histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia.

  10. Percutaneous Stent-Graft Repair of a Mycotic Pulmonary Artery Pseudoaneurysm

    International Nuclear Information System (INIS)

    Chou Meichun; Liang Hueilung; Pan Huayban; Yang Chienfang

    2006-01-01

    Ruptured mycotic pulmonary pseudoaneurysm is a lethal complication. Emergent surgical repair is usually recommended, but still associated with a high mortality rate. We present a patient in whom mycotic pulmonary pseudoaneurysm was a complication after surgical lobectomy 2 weeks earlier. This patient had suffered from repeated massive hemoptysis. After emergent surgical repair of the ruptured pulmonary artery stump, another episode of massive hemorrhage occurred. The pulmonary arteriogram revealed a segmental stenosis and a large, wide-necked, lobulated pseudoaneurysm at the left proximal pulmonary artery. We deployed a balloon-expandable stent-graft (48 mm in length mounted on a 12 mm x 40 mm angioplasty balloon) across the stenotic segment and the neck of the pulmonary pseudoaneurysm. Hemostasis was achieved immediately and, under a 4-week antibiotic treatment, patient was transferred to a local hospital for medical care. This case report demonstrates the benefit of minimally invasive endovascular therapy in a critically ill patient. A literature review of the etiology and management of mycotic pulmonary pseudoaneurysm is included

  11. Investigation Of Interaction Between Nitinol Stent And A Vascular Plaque Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Recep Güneş

    2012-06-01

    Full Text Available In this study, the interaction between the Nitinol stent and the artery with plaque was investigated using finite element method. The occurring pressure values during the cardiac contraction (systolic and loosening (diastolic were applied as loading to the modeled system with Nitinol stent. In the light of the stress values, the suitability of the Nitinol stent in an artery with plaque was investigated. In the analysis, Nitinol stent was assumed to be shape memory alloy, and artery and plaque were assumed to behave linearly elastic. As a result, the stress and deformations in the plaque and artery due to the interference of Nitinol stent were discussed and concluded that the structure of artery with plaque can be expanded in accordance with Nitinol stent.

  12. Rationale and Design of a Randomized Clinical Comparison of Everolimus-Eluting (Xience V/Promus) and Sirolimus-Eluting (Cypher Select+) Coronary Stents in Unselected Patients with Coronary Heart Disease

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Tilsted, Hans Henrik

    2010-01-01

    with Clinical Outcome (SORT OUT) IV trial was designed as a prospective, multi-center, open-label, all-comer, two-arm, randomized, non-inferiority study comparing the everolimus-eluting stent with the sirolimus-eluting stent in the treatment of atherosclerotic coronary artery lesions. Based on a non...

  13. Thoracic Stent Graft Implantation for Aortic Coarctation with Patent Ductus Arteriosus via Retroperitoneal Iliac Approach in the Presence of Small Sized Femoral Artery

    Directory of Open Access Journals (Sweden)

    Ozge Korkmaz

    2016-01-01

    Full Text Available Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach.

  14. Fatal Intraventricular Hemorrhage After the Extracranial Carotid Artery Angioplasty and Stent Placement

    International Nuclear Information System (INIS)

    Krajickova, Dagmar; Krajina, Antonin; Nova, Marketa; Raupach, Jan

    2005-01-01

    We report on a 72-year-old female with an unusual intracranial bleeding complication after an extracranial carotid artery stenting procedure performed for a tight left ICA stenosis associated with contralateral carotid occlusion. Two hours after the procedure, the initial signs of intracranial bleeding appeared that led to the patient's demise 5 days later. A brain CT showed and autopsy proved massive intraventricular bleeding. To our knowledge, our case is only the second report of isolated reperfusion intraventricular hemorrhage post-CAS

  15. Long-term clinical and quality of life outcomes after stenting of femoropopliteal artery stenosis: 3-year results from the STROLL study.

    Science.gov (United States)

    Bunte, Matthew C; Cohen, David J; Jaff, Michael R; Gray, William A; Magnuson, Elizabeth A; Li, Haiyan; Feiring, Andrew; Cioppi, Marco; Hibbard, Robert; Gray, Bruce; Khatib, Yazan; Jessup, David; Patarca, Roberto; Du, Jing; Stoll, Hans-Peter; Massaro, Joe; Safley, David M

    2018-03-09

    To evaluate the clinical and health status outcomes of patients undergoing superficial femoral artery (SFA) revascularization using the Shape Memory Alloy Recoverable Technology (S.M.A.R.T.®) nitinol self-expanding stent through 3 years of follow-up. Limited long-term data are available describing the durability of benefits after femoropopliteal revascularization. In a multicenter, prospective, core-lab adjudicated study, 250 subjects with de novo or restenotic femoropopliteal arterial lesions were treated with the S.M.A.R.T.® stent. The primary endpoint of target vessel patency, a composite of ultrasound-assessed patency and freedom from clinically driven target lesion revascularization (TLR), was evaluated through 3 years. Secondary endpoints included stent fracture and health status. Health status was measured using generic and disease-specific instruments, including the Peripheral Artery Questionnaire (PAQ). At 3-year follow-up, Kaplan-Meier estimated target vessel patency was 72.7%, freedom from clinically driven TLR was 78.5%, and the incidence of stent fracture was 3.6%. The PAQ summary score was markedly impaired at baseline (mean 37.3 ± 19.6 points) and improved substantially at 1 month (mean change from baseline of 31.4 points, 95% CI: 28.5-34.3; P PAQ were largely preserved through 3 years of follow-up (mean change from baseline, 28.0 points, 95% CI: 24.3-31.7; P < 0.0001). In patients undergoing revascularization for moderately complex SFA disease, use of the self-expanding S.M.A.R.T® stent was associated with a high rate of target vessel patency through 3 years and led to substantial and sustained health status benefits. © 2018 Wiley Periodicals, Inc.

  16. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre...

  17. A Case of Late Femoral Pseudoaneurysm Caused by Stent Disconnection

    International Nuclear Information System (INIS)

    Rivolta, Nicola; Fontana, Federico; Piffaretti, Gabriele; Tozzi, Matteo; Carrafiello, Gianpaolo

    2010-01-01

    We present the case of a late superficial femoral artery stent disconnection causing an asymptomatic pseudoaneurysm successfully treated with a stent-graft. A 67-year-old female was referred to our department for evaluation of claudication of the left lower limb and was diagnosed to have a total occlusion of the superficial femoral artery. Three nitinol stents were used to revascularize this artery. At 48 months, duplex-ultrasonography control revealed the presence of a 45-mm saccular femoral dilatation; X-rays and CT angiography showed fractures of the proximal stents and the presence of a pseudoaneurysm at the site of the distal stents disconnection. The pseudoaneurysm was excluded using two stent-grafts. We conclude that patients and surgeons should be aware of structural complications with all stents. Rigorous follow-up controls should be mandatory. Endovascular repair proved to be feasible and durable to manage a previous endovascular procedure.

  18. Wingspan stent-assisted coiling of intracranial aneurysms with symptomatic parent artery stenosis: Experience in 35 patients with mid-term follow-up results

    International Nuclear Information System (INIS)

    Gao Xu; Liang Guobiao; Li Zhiqing; Wei Xuezhong; Wang Xiaogang; Zhang Haifeng; Feng Sizhe; Lin Jun

    2012-01-01

    Background: There is a potential risk of aneurysm rupture after parent artery revascularization because of increased blood flow. The purpose of this study is to assess the efficacy and safety of Wingspan stent-assisted coil embolization in the treatment of intracranial aneurysms with symptomatic parent artery stenosis. Methods: Thirty-five consecutive patients (19 men, 16 women; age range, 48–79 years; mean age, 60.4 years) harboring 35 unruptured wide-necked or fusiform intracranial aneurysms (mean size 6.8 mm; range 2.5–18 mm.) with symptomatic parent artery stenosis (mean degree 71.1%; range 50–92%) were treated with the Wingspan stent-assisted coiling. Twenty-four lesions were located in the anterior circulation and eleven in the posterior circulation. Patients were premedicated with antiplatelet therapy consisting of aspirin 300 mg and clopidogrel 75 mg for at least 3 days before the procedure. Following pre-dilatation and stent placement, a coiling microcatheter entered the aneurysm through the interstices of the stent, and then coiling was performed. After the procedure, clopidogrel 75 mg daily was recommended for an additional 30 days, and aspirin 100 mg was recommended throughout follow-up. For all patients, clinical follow-up was conducted by clinic visitation, or telephone interview. Angiographic follow-up with DSA was recommended at 6 months and 1 year after the procedure. Angiography follow-up (mean time 10.6 months) was obtained in 31 cases (88.6%). The technical feasibility of the procedure, procedure-related complications, angiographic results, clinical outcome and follow-up angiography were evaluated. Results: In every case, technical success was achieved. The degree of stenosis was reduced from 71.1% to 17.4% after balloon angioplasty and stenting. Immediate angiography demonstrated complete occlusion in 25 cases (71.4%), neck remnant in 7 cases (20.0%), and incomplete occlusion in 3 cases (8.6%). Procedure-related morbidity occurred in two

  19. First-in-man randomised comparison of the BuMA Supreme biodegradable polymer sirolimus-eluting stent versus a durable polymer zotarolimus-eluting coronary stent: the PIONEER trial.

    Science.gov (United States)

    von Birgelen, Clemens; Asano, Taku; Amoroso, Giovanni; Aminian, Adel; Brugaletta, Salvatore; Vrolix, Mathias; Hernandez-Antolín, Rosana; van de Harst, Pim; Iñiguez, Andres; Janssens, Luc; Smits, Pieter C; Wykrzykowska, Joanna J; Ribeiro, Vasco Gama; Pereira, Hélder; da Silva, Pedro Canas; Piek, Jan J; Onuma, Yoshinobu; Serruys, Patrick W; Sabaté, Manel

    2018-04-20

    A second iteration of a sirolimus-eluting stent (SES) that has a biodegradable PLGA polymer coating with an electrografting base layer on a thin-strut (80 µm) cobalt-chromium platform (BuMA Supreme; SINOMED, Tianjin, China) has been developed. This first-in-man trial aimed to assess the efficacy and safety of the novel device. This randomised, multicentre, single-blinded, non-inferiority trial compared the BuMA Supreme SES versus a contemporary durable polymer zotarolimus-eluting stent (ZES) in terms of angiographic in-stent late lumen loss (LLL) at nine-month follow-up as the primary endpoint. A total of 170 patients were randomly allocated to treatment with either SES (n=83) or ZES (n=87). At nine-month angiographic follow-up, in-stent LLL was 0.29±0.33 mm in the SES group and 0.14±0.37 mm in the ZES group (pnon-inferiority=0.45). The in-stent percent diameter stenosis and the binary restenosis rate of the two treatment arms were similar (19.2±12.0% vs. 16.1±12.6%, p=0.09, and 3.3% vs. 4.4%, p=1.00, respectively). At 12-month clinical follow-up, there was no difference between treatment arms with regard to the device-oriented composite clinical endpoint (4.9% vs. 5.7%; p=0.72). The PIONEER trial did not meet its primary endpoint in terms of in-stent LLL at nine-month follow-up. However, this result did not translate into any increase in restenosis rate or impairment in 12-month clinical outcomes.

  20. Differences in Endothelial Injury After Balloon Angioplasty, Insertion of Balloon-Expanded Stents or Release of Self-Expanding Stents: An Electron Microscopic Experimental Study

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Carlemalm, Erik; Cwikiel, Wojciech

    1999-01-01

    Purpose: To evaluate which of six different commonly available stents inserted into an artery without percutaneous transluminal angioplasty (PTA) causes the least endothelial damage. To compare the degree of endothelial injury after insertion of such a stent with injury caused by PTA. Methods: Twelve healthy pigs were used in the experiments. In the first part of the study six different types of stents were inserted into the common iliac arteries. In the second part of the study self-expanding stents with large spaces between the wires were used. PTA was performed in the contralateral iliac artery. The pigs were killed immediately after the procedure and resected specimens examined after fixation, using scanning electron microscopy. Results: All procedures but two were accomplished successfully. More endothelium was preserved after insertion of self-expanding stents with large spaces between the wires, compared with stents with small spaces and balloon-expanded stents. After insertion of self-expanding stents with large spaces, 50.1% ± 16.4% of the endothelium remained intact, compared with only 5.6% ± 7.7% after PTA. The difference was statistically significant (p < 0.001). Conclusion: Self-expanding stents with large spaces between the wires, inserted without PTA, cause less damage to the endothelium than other stents and significantly less damage than PTA

  1. [Current guidelines on carotid artery stenting. Critical evaluation].

    Science.gov (United States)

    Hein-Rothweiler, R; Mudra, H

    2013-11-01

    Scientific data underlying current guidelines on treatment of carotid artery stenosis is subject to interdisciplinary discussion. In particular selective weighting of the randomized European studies leads to conflicting levels of recommendation and levels of evidence, especially when directly comparing guidelines under surgical versus endovascular guidance. Surgical guidelines recommend a limitation of carotid artery stenting (CAS) to symptomatic patients with specific surgical/anatomical disadvantages and/or severe comorbidities. The European Society of Cardiology (ESC) guidelines recommend the use of CAS only in patients at increased surgical risk but at the same time requires morbidity and mortality rates comparable to those of surgical interventions. Even one step further, the American guidelines and specifically the associated comments of the German Society of Cardiology on the above mentioned ESC guidelines put CAS and carotid endarterectomy (CEA) on a par in terms of treatment alternatives, presupposing analogous CEA complication rates. Differential interpretation of the so far inadequate data is a common issue of current evidence-based medicine. The difficulty in conceptualization of new studies concerning the therapy of carotid stenosis lies in the funding these large projects and also on the high patient number required to achieve adequate statistical power. Furthermore, during the estimated long study period substantial changes of current techniques and devices can be anticipated which might render the study results in part outdated by the time of publication. However, as long as no new randomized study results comparing medical, surgical and interventional treatment of carotid stenosis are available, the question on the optimal therapy for patients with carotid artery disease remains unanswered.

  2. Neointimal responses 3 months after 32P β-emitting stent placement

    International Nuclear Information System (INIS)

    Farb, Andrew; Tang, Anita L.; Shroff, Sweta; Sweet, William; Virmani, Renu

    2000-01-01

    Purpose: Studies have shown a potential benefit of brachytherapy in preventing restenosis. However, the effects of intravascular radiation on arterial healing have not been well-established. The purpose of this study was to explore the histologic changes following placement of β-emitting radioactive stents in arteries focusing on intimal responses and endothelialization. Methods and Materials: 3.0-mm β-emitting 32 P stents (6-μCi and 24-μCi) were placed in rabbit iliac arteries with nonradioactive stents serving as controls. Animals were euthanized at 3 months and histologic assessment, morphometry, and analysis of endothelialization were performed. Results: The lumen areas of 24-μCi stents (4.24 ± 0.22 mm 2 , p 2 , p 2 ). The mean lumen percent stenosis was 11.4 ± 3.0% in the 24-μCi stents (p 32 P β-emitting stents reduce neointimal growth, but healing is incomplete with poor endothelialization at 3 months. Longer-term studies with complete arterial healing are needed to determine whether there is sustained neointimal inhibition by stent-delivered brachytherapy

  3. Local sustained delivery of acetylsalicylic acid via hybrid stent with biodegradable nanofibers reduces adhesion of blood cells and promotes reendothelialization of the denuded artery

    Directory of Open Access Journals (Sweden)

    Lee CH

    2014-01-01

    Full Text Available Cheng-Hung Lee,1,2 Yu-Huang Lin,3 Shang-Hung Chang,1 Chun-Der Tai,3 Shih-Jung Liu,2 Yen Chu,4 Chao-Jan Wang,5 Ming-Yi Hsu,5 Hung Chang,6 Gwo-Jyh Chang,7 Kuo-Chun Hung,1 Ming-Jer Hsieh,1 Fen-Chiung Lin,1 I-Chang Hsieh,1 Ming-Shien Wen,1 Yenlin Huang81Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Linkou, 2Department of Mechanical Engineering, 3Graduate Institute of Medical Mechatronics, Chang Gung University, 4Laboratory of Cardiovascular Physiology, Division of Thoracic and Cardiovascular Surgery, 5Department of Medical Imaging and Intervention, 6Hematology-Oncology Division, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, 7Graduate Institute of Clinical Medicinal Sciences, Chang Gung University College of Medicine, Linkou, 8Department of Anatomical Pathology, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, TaiwanAbstract: Incomplete endothelialization, blood cell adhesion to vascular stents, and inflammation of arteries can result in acute stent thromboses. The systemic administration of acetylsalicylic acid decreases endothelial dysfunction, potentially reducing thrombus, enhancing vasodilatation, and inhibiting the progression of atherosclerosis; but, this is weakened by upper gastrointestinal bleeding. This study proposes a hybrid stent with biodegradable nanofibers, for the local, sustained delivery of acetylsalicylic acid to injured artery walls. Biodegradable nanofibers are prepared by first dissolving poly(D,L-lactide-co-glycolide and acetylsalicylic acid in 1,1,1,3,3,3-hexafluoro-2-propanol. The solution is then electrospun into nanofibrous tubes, which are then mounted onto commercially available bare-metal stents. In vitro release rates of pharmaceuticals from nanofibers are characterized using an elution method, and a high-performance liquid chromatography assay. The experimental results suggest that biodegradable nanofibers

  4. Stent malapposition, as a potential mechanism of very late stent thrombosis after bare-metal stent implantation: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Higuma, Takumi, E-mail: higuma@cc.hirosaki-u.ac.jp; Abe, Naoki; Hanada, Kenji; Yokoyama, Hiroaki; Tomita, Hirofumi; Okumura, Ken

    2014-04-15

    A 90-year-old man was admitted to our hospital with acute ST-segment elevation myocardial infarction. He had a history of post-infarction angina pectoris 79 months ago and had a bare-metal stent (BMS) implanted in the proximal left anterior descending artery at our hospital. Emergent coronary angiography demonstrated thrombotic occlusion in the previously stented segment. After catheter thrombectomy, antegrade flow was restored, but 90% stenosis with haziness persisted in the proximal and distal portions of the previously stented segment. Intravascular ultrasound imaging showed interstrut cavities or stent malapposition at the proximal and distal sites of stented segment. In close proximity to the sites, residual thrombi were also observed. Optical coherence tomography (OCT) demonstrated neither lipid-laden neointimal tissue nor rupture but clearly demonstrated residual thrombus adjacent to the malapposed region in addition to the stent malapposition. PCI with balloon was successfully performed and stent apposition was confirmed by OCT. Stent malapposition is an unusual mechanism of very late stent thrombosis after BMS implantation. OCT can clearly reveal the etiology of stent thrombosis.

  5. The degradation and transport mechanism of a Mg-Nd-Zn-Zr stent in rabbit common carotid artery: A 20-month study.

    Science.gov (United States)

    Zhang, Jian; Li, Haiyan; Wang, Wu; Huang, Hua; Pei, Jia; Qu, Haiyun; Yuan, Guangyin; Li, Yongdong

    2018-03-15

    Mg-based stent is a promising candidate of the next generation fully degradable vascular stents. The latest progress includes the CE approval of the Magmaris ® WE43 based drug eluting stent. However, so far, the long term (more than 1 year implantation) in vivo degradation and the physiological effects caused by the degradation products were still unclear. In this study, a 20 month observation was carried out after the bare Mg-Nd-Zn-Zr (abbr. JDBM) stent prototype was implanted into the common carotid artery of New Zealand white rabbit in order to evaluate its safety, efficacy and especially degradation behavior. The degradation of the main second phase Mg 12 Nd was also studied. Results showed that the bare JDBM stent had good safety and efficacy with a complete re-endothelialization within 28 days. The JDBM stent struts were mostly replaced in situ by degradation products in 4 month. The important finding was that the volume and Ca concentration of the degradation products decreased in the long term, eliminating the clinicians' concern of possible vessel calcification. In addition, the alloying elements Mg and Zn in the stent could be safely metabolized as continuous enrichment in any of the main organs were not detected although Nd and Zr showed an abrupt increase in spleen and liver after 1 month implantation. Collectively, the long term in vivo results showed the rapid re-endothelialization of JDBM stent and the long term safety of the degradation products, indicating its great potential as the backbone of the fully degradable vascular stent. Mg-based stent is a promising candidate of the next generation fully degradable stents, especially after the recent market launch of one of its kind (Magmaris). However the fundamental question about the long term degradation and metabolic mechanism of Mg-based stent and its degradation products remain unanswered. We implanted our patented Mg-Nd-Zn-Zr bare stent into the common carotid artery of rabbits and

  6. Assessment of effectiveness of endovascular treatment of common and external iliac artery stenosis/occlusion using self-expanding Jaguar SM stents

    International Nuclear Information System (INIS)

    Kordecki, Kazimierz; Łukasiewicz, Adam; Nowicki, Mirosław; Lewszuk, Andrzej; Kowalewski, Radosław; Panek, Bogusław; Zawadzki, Michał; Michalak, Paweł; Gacko, Marek; Łebkowska, Urszula

    2012-01-01

    The goal of this work was to assess the effectiveness of endovascular treatment of common and external iliac artery stenosis/occlusion classified according to TASC using a self-expanding stent Jaguar SM. The study group included 95 patients (61 men and 34 women) who underwent treatment for stenosis or occlusion of lower limb arteries at the Department of Radiology of the University Hospital in Bialystok and the Diagnostic Radiology Department of the Central Clinical Hospital of the Ministry of Interior (MSWiA) in Warsaw between 2005 and 2007. All arterial lesions were of atherosclerotic etiology. The shortest stenotic fragment was 10 mm long and the longest occluded arterial fragment did not exceed 90 mm. Morphological classification of iliac artery lesions in treated patients was performed according to TASC II classification and included 10 patients with type A, 39 cases of type B, 36 with type C and 10 patients with type D lesions. Endovascular procedure failed to restore flow in five patients with TASC type D lesions, who were later referred for surgery. One patient suffered a complication – vessel perforation during predilatation, and had a stentgraft implanted. In 95% of patients stents were expanded using a balloon after implantation. Good results were achieved in practically all patients who underwent stent implantation. Patients were subjected to follow-up clinical and imaging evaluation during next 1–24 months. Success rate of the performed procedures as well as in a 30-day observation period was 100% in case of stenosis and 80% in case of vessel occlusion. A follow-up after 12 and 24 months showed patency of treated vessels in 84% and 76% of patients, respectively

  7. Potential advantages and limitations of the Leo stent in endovascular treatment of complex cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv Xianli; Li Youxiang; Jiang Chuhan; Yang Xinjian [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China); Wu Zhongxue, E-mail: ttyyzjb@sina.com [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China)

    2011-08-15

    Objective: The Leo self-expandable stent is a new retractable stent that is delivered via a conventional catheter. The aim of this study was to evaluate the use of this stent for endovascular treatment of complex aneurysms. Methods: Twenty-eight complex cerebral aneurysms (27 saccular and 1 fusiform) in 28 patients were treated electively. They were located at the internal carotid artery (17), basilar trunk (3), anterior cerebral artery (1), anterior communicating artery (3), vertebral artery (2) and middle cerebral artery (2). One aneurysm exhibited recanalization after primary endovascular treatment without stent. Clinical outcome was assessed with the modified Glasgow Outcome Scale. Results: Deployment of Leo stent was successful in 26 lesions, and difficulties in stent positioning due to tortuous cerebral circulation in 2 cases, which were treated with Neuroform stent. Additional coil embolization was performed in 26 lesions. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in all aneurysms. There was no immediate coil embolization was chosen in 3 cases because of subsequent reduced filling of the aneurysms with contrast agent on angiograms. There were 3 asymptomatic parent artery occlusion related to the deployment of the Leo stent, one stent migration. Follow-up revealed patent stents in the remaining cases. No angiographic recurrences arose. Conclusion: The Leo stent is very useful for endovascular treatment of complex cerebral aneurysms because it is easy to navigate and place precisely. A drawback is that in-stent thrombosis caused by stent placement and stiffer delivery catheters to place larger stents.

  8. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    International Nuclear Information System (INIS)

    Ahmed, Ahmed T.; Mohammed, Khaled; Chehab, Monzer; Brinjikji, Waleed; Hassan Murad, M.; Cloft, Harry; Bjarnason, Haraldur

    2016-01-01

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  9. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Ahmed T., E-mail: Ahmed.Ahmed1@mayo.edu; Mohammed, Khaled, E-mail: Mohammed.Khaled@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Chehab, Monzer, E-mail: moe.chehab@beumont.edu [Oakland University William Beaumont School of Medicine, Department of Diagnostic Radiology and Molecular Imaging (United States); Brinjikji, Waleed, E-mail: Brinjikji.Waleed@mayo.edu [Mayo Clinic, Department of Radiology (United States); Hassan Murad, M., E-mail: Murad.Mohammad@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Cloft, Harry, E-mail: Cloft.Harry@mayo.edu; Bjarnason, Haraldur, E-mail: Bjarnason.Haraldur@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2016-05-15

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  10. Indications and applications of arterial stents for stroke prevention in atherosclerotic intracranial stenosis.

    Science.gov (United States)

    Fields, Jeremy D; Liu, Kenneth C; Barnwell, Stanley L; Clark, Wayne M; Lutsep, Helmi L

    2010-01-01

    Intracranial stenosis accounts for 8-10% of all ischemic strokes in North America, a frequency slightly less than that of extracranial carotid stenosis. Among patients presenting with transient ischemic attack or stroke due to intracranial stenosis, the risk of recurrent stroke in the first year after initial symptoms is about 14%. Those with high-risk features (recent stroke and severe stenosis) have up to a 23% rate of recurrent stroke in the year after their initial event. Angioplasty with stenting has emerged as a potential treatment strategy, particularly in high-risk patients, although evidence is currently limited to uncontrolled prospective trials and retrospective case series. In this article, we critically review the clinical results supporting the use of stenting and highlight some key considerations in the application of this technology, including patient selection, procedural management, technical issues, and risk factors for complications and in-stent restenosis.

  11. XIENCE V everolimus-eluting coronary stent system: a novel second generation drug-eluting stent

    NARCIS (Netherlands)

    Beijk, Marcel A. M.; Piek, Jon J.

    2007-01-01

    Drug-eluting stents (DES) have been shown to be safe and significantly reduce clinical events and angiographic restenosis in the percutaneous treatment of coronary artery disease. Currently, three DES have been approved in Europe and Northern America: the sirolimus-eluting stent (SES), the

  12. Correlates and Impact of Coronary Artery Calcifications in Women Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents

    DEFF Research Database (Denmark)

    Giustino, Gennaro; Mastoris, Ioannis; Baber, Usman

    2016-01-01

    OBJECTIVES: The aim of this study was to investigate the clinical correlates and prognostic impact of coronary artery calcification (CAC) in women undergoing percutaneous coronary intervention with drug-eluting stents (DES). BACKGROUND: The clinical correlates and the prognostic significance of CAC...

  13. High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation

    International Nuclear Information System (INIS)

    Nemes, Balazs; Lukacs, Levente; Balazs, Gyoergy; Dosa, Edit; Berczi, Viktor; Huettl, Kalman

    2009-01-01

    Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 ± 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic and computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 ± 8% before the procedure to 15.7 ± 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.

  14. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  15. Outcome of Carotid Artery Stenting for Radiation-Induced Stenosis

    International Nuclear Information System (INIS)

    Dorresteijn, Lucille; Vogels, Oscar; Leeuw, Frank-Erik de; Vos, Jan-Albert; Christiaans, Marleen H.; Ackerstaff, Rob; Kappelle, Arnoud C.

    2010-01-01

    Purpose: Patients who have been irradiated at the neck have an increased risk of symptomatic stenosis of the carotid artery during follow-up. Carotid angioplasty and stenting (CAS) can be a preferable alternative treatment to carotid endarterectomy, which is associated with increased operative risks in these patients. Methods and Materials: We performed a prospective cohort study of 24 previously irradiated patients who underwent CAS for symptomatic carotid stenosis. We assessed periprocedural and nonprocedural events including transient ischemic attack (TIA), nondisabling stroke, disabling stoke, and death. Patency rates were evaluated on duplex ultrasound scans. Restenosis was defined as a stenosis of >50% at the stent location. Results: Periprocedural TIA rate was 8%, and periprocedural stroke (nondisabling) occurred in 4% of patients. After a mean follow-up of 3.3 years (range, 0.3-11.0 years), only one ipsilateral incident event (TIA) had occurred (4%). In 12% of patients, a contralateral incident event was present: one TIA (4%) and two strokes (12%, two disabling strokes). Restenosis was apparent in 17%, 33%, and 42% at 3, 12, and 24 months, respectively, although none of the patients with restenosed vessels became symptomatic. The length of the irradiation to CAS interval proved the only significant risk factor for restenosis. Conclusions: The results of CAS for radiation-induced carotid stenosis are favorable in terms of recurrence of cerebrovascular events at the CAS site.

  16. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  17. Endothelial cell repopulation after stenting determines in-stent neointima formation: effects of bare-metal vs. drug-eluting stents and genetic endothelial cell modification.

    Science.gov (United States)

    Douglas, Gillian; Van Kampen, Erik; Hale, Ashley B; McNeill, Eileen; Patel, Jyoti; Crabtree, Mark J; Ali, Ziad; Hoerr, Robert A; Alp, Nicholas J; Channon, Keith M

    2013-11-01

    Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. Endothelial cell repopulation was assessed en face in stented arteries in ApoE(-/-) mice with endothelial-specific LacZ expression. Stent deployment resulted in near-complete denudation of endothelium, but was followed by endothelial cell repopulation, by cells originating from both bone marrow-derived endothelial progenitor cells and from the adjacent vasculature. Paclitaxel-eluting stents reduced neointima formation (0.423 ± 0.065 vs. 0.240 ± 0.040 mm(2), P = 0.038), but decreased endothelial cell repopulation (238 ± 17 vs. 154 ± 22 nuclei/mm(2), P = 0.018), despite complete strut coverage. To test the effects of selectively improving endothelial cell function, we used transgenic mice with endothelial-specific overexpression of GTP-cyclohydrolase 1 (GCH-Tg) as a model of enhanced endothelial cell function and increased NO production. GCH-Tg ApoE(-/-) mice had less neointima formation compared with ApoE(-/-) littermates (0.52 ± 0.08 vs. 0.26 ± 0.09 mm(2), P = 0.039). In contrast to paclitaxel-eluting stents, reduced neointima formation in GCH-Tg mice was accompanied by increased endothelial cell coverage (156 ± 17 vs. 209 ± 23 nuclei/mm(2), P = 0.043). Drug-eluting stents reduce not only neointima formation but also endothelial cell repopulation, independent of strut coverage. In contrast, selective targeting of endothelial cell function is sufficient to improve endothelial cell repopulation and reduce neointima formation. Targeting endothelial cell function is a rational therapeutic strategy to improve vascular healing and decrease neointima formation after stenting.

  18. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.

    Science.gov (United States)

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R

    2017-02-01

    The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; Pstent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels 15 mm length. © 2016 John Wiley & Sons Ltd.

  19. A Systematic Review of Outcomes Following Percutaneous Transluminal Angioplasty and Stenting in the Treatment of Transplant Renal Artery Stenosis

    NARCIS (Netherlands)

    Ngo, A. T.; Markar, S. R.; de Lijster, M. S.; Duncan, N.; Taube, D.; Hamady, M. S.

    2015-01-01

    To evaluate outcomes following treatment of transplant renal artery stenosis by percutaneous transluminal angioplasty and stent insertion. A literature search was performed using Pubmed, MEDLINE, Embase, Wiley Interscience and the Cochrane Library databases. Outcome measures were glomerular

  20. Endovascular stenting for treatment of complex intracranial aneurysms: preliminary outcome

    International Nuclear Information System (INIS)

    Huang Qinghai; Liu Jianmin; Xu Yi; Hong Bo; Zhao Wenyuan; Zhou Xiaoping

    2004-01-01

    Objective: To summarize the technique and efficiency of combined endovascular stenting and Guglielmi detachable coils (GDC) packing for the treatment of intracranial wide-necked bifurcation aneurysms and recanalized aneurysms. Methods: The coronary stents were implanted across the necks of 5 intracranial wide-necked aneurysms (two at bifurcation of ICA, one at basilar artery and two recanalized PcoA aneurysms). The porous stents covered the ostia of vital side branches and perforating vessels in three cases. Microcatheters were introduced into the aneurysmal sac through the stent mesh and then followed by GDCs embolizing the aneurysms. Results: The stents were deployed in parent artery in all cases. Total occlusion was obtained in 4 cases, while more than 90% in one case with patency of the parent arteries and vital perforating arteries. Follow-up angiography performed in all patients 3-6 months later revealed no intrastent stenosis. All the patients recovered well except III nerve palsy in one patient which diminished 3 months later. Conclusion: Endovaseular therapy combined stent implantation and microcoil placement maybe a valid alteration for the treatment of wide-necked bifurcation aneurysms and recanalized aneurysms, which shows promise clinical application in the future. The ostia of vital side branches covered with stents showed no effect on hemodynamics. (authors)

  1. Optimal Scanning Protocols for Dual-Energy CT Angiography in Peripheral Arterial Stents: An in Vitro Phantom Study

    Directory of Open Access Journals (Sweden)

    Abdulrahman Almutairi

    2015-05-01

    Full Text Available Objective: To identify the optimal dual-energy computed tomography (DECT scanning protocol for peripheral arterial stents while achieving a low radiation dose, while still maintaining diagnostic image quality, as determined by an in vitro phantom study. Methods: Dual-energy scans in monochromatic spectral imaging mode were performed on a peripheral arterial phantom with use of three gemstone spectral imaging (GSI protocols, three pitch values, and four kiloelectron volts (keV ranges. A total of 15 stents of different sizes, materials, and designs were deployed in the phantom. Image noise, the signal-to-noise ratio (SNR, different levels of adaptive statistical iterative reconstruction (ASIR, and the four levels of monochromatic energy for DECT imaging of peripheral arterial stents were measured and compared to determine the optimal protocols. Results: A total of 36 scans with 180 datasets were reconstructed from a combination of different protocols. There was a significant reduction of image noise with a higher SNR from monochromatic energy images between 65 and 70 keV in all investigated preset GSI protocols (p < 0.05. In addition, significant effects were found from the main effect analysis for these factors: GSI, pitch, and keV (p = 0.001. In contrast, there was significant interaction on the unstented area between GSI and ASIR (p = 0.015 and a very high significant difference between keV and ASIR (p < 0.001. A radiation dose reduction of 50% was achieved. Conclusions: The optimal scanning protocol and energy level in the phantom study were GSI-48, pitch value 0.984, and 65 keV, which resulted in lower image noise and a lower radiation dose, but with acceptable diagnostic images.

  2. Multimodal Therapy for the Treatment of Severe Ischemic Stroke Combining Endovascular Embolectomy and Stenting of Long Intracranial Artery Occlusion

    Science.gov (United States)

    Bunc, Matjaž; Kocijančič, Igor J.; Pregelj, Rado; Dolenc, Vinko V.

    2010-01-01

    Embolic occlusion of cerebral arteries is a major cause for stroke. Intravenous thrombolysis showed positive results in this condition, however even when strict criteria are used, the risk of hemorrhagic transformation is possible. Microsurgical embolectomy has been described earlier. Purpose. We performed multimodal therapy of cerebral artery occlusion. Case Report. We present a case of a 49-year-old female patient who—according to the National Institute of Health Stroke Scale (NIHSS)—was rated as 19 due to acute occlusion of the horizontal segment of the left middle cerebral artery (MCA). After failed i.v. thrombolysis, only a part of the clot could be evacuated by the endovascular approach—without restoration of blood flow. Normal patency of the left MCA was re-established after stenting. Within 72 hours, the patient had an NIHSS score of 14, with a small haematoma in the left hemisphere. Conclusion. In our case multimodal therapy combining i.v. thrombolysis, mechanical disruption of thrombus, MCA stenting and platelet function antagonists, resulted in successful recanalization of the acutely occluded left MCA. PMID:20671974

  3. Multimodal therapy for the treatment of severe ischemic stroke combining endovascular embolectomy and stenting of long intracranial artery occlusion.

    Science.gov (United States)

    Bunc, Matjaz; Kocijancic, Igor J; Pregelj, Rado; Dolenc, Vinko V

    2010-01-01

    Embolic occlusion of cerebral arteries is a major cause for stroke. Intravenous thrombolysis showed positive results in this condition, however even when strict criteria are used, the risk of hemorrhagic transformation is possible. Microsurgical embolectomy has been described earlier. Purpose. We performed multimodal therapy of cerebral artery occlusion. Case Report. We present a case of a 49-year-old female patient who-according to the National Institute of Health Stroke Scale (NIHSS)-was rated as 19 due to acute occlusion of the horizontal segment of the left middle cerebral artery (MCA). After failed i.v. thrombolysis, only a part of the clot could be evacuated by the endovascular approach-without restoration of blood flow. Normal patency of the left MCA was re-established after stenting. Within 72 hours, the patient had an NIHSS score of 14, with a small haematoma in the left hemisphere. Conclusion. In our case multimodal therapy combining i.v. thrombolysis, mechanical disruption of thrombus, MCA stenting and platelet function antagonists, resulted in successful recanalization of the acutely occluded left MCA.

  4. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation

    DEFF Research Database (Denmark)

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian

    2017-01-01

    -stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. METHODS/RESULTS: The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability...... of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. CONCLUSION: In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt...... compared to segments treated with a DES (5.4% vs 0.76%; P15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold...

  5. Endovascular Treatment of a Giant Superior Mesenteric Artery Pseudoaneurysm Using a Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Pipitone, Vincenzo; Konda, Daniel; Pendenza, Gianluca; Spinelli, Alessio; Stefanini, Matteo; Simonetti, Giovanni

    2005-01-01

    A 68-year-old woman presenting with gastrointestinal bleeding (hematocrit 19.3%) and in a critical clinical condition (American Society of Anesthesiologists grade 4) from a giant superior mesenteric artery pseudoaneurysm (196.0 x 131.4 mm) underwent emergency endovascular treatment. The arterial tear supplying the pseudoaneurysm was excluded using a 5.0 mm diameter and 31 mm long monorail expanded polytetrafluoroethylene (ePTFE)-covered self-expanding nitinol stent. Within 6 days of the procedure, a gradual increase in hemoglobin levels and a prompt improvement in the clinical condition were observed. Multislice CT angiograms performed immediately, 5 days, 30 days and 3 months after the procedure confirmed the complete exclusion of the pseudoaneurysm

  6. Stent-assisted angioplasty for intracranial atherosclerosis

    International Nuclear Information System (INIS)

    Nakahara, Toshinori; Sakamoto, Shigeyuki; Hamasaki, Osamu; Sakoda, Katsuaki

    2002-01-01

    We report on two patients with intracranial atherosclerosis of the carotid artery or vertebral artery treated with stent-assisted angioplasty. Both patients have severe intracranial atherosclerosis (>70%) with refractory symptoms despite optimal medical treatment. In both patients, a coronary balloon-expandable stent was successfully placed using a protective balloon technique without procedural complications. The patients were asymptomatic and neurologically intact at a mean clinical follow-up of 13 months. Follow-up angiograms did not show restenosis 3 or 4 months after procedure, respectively. Stent-assisted angioplasty for intracranial atherosclerosis in the elective patient has proven effective, with an acceptable low rate of morbidity and mortality. (orig.)

  7. Long-term outcomes of coronary artery bypass grafting versus stent-PCI for unprotected left main disease: a meta-analysis.

    Science.gov (United States)

    De Rosa, Salvatore; Polimeni, Alberto; Sabatino, Jolanda; Indolfi, Ciro

    2017-09-06

    Coronary artery bypass graft (CABG) surgery has traditionally represented the standard of care for left main coronary artery (LMCA) disease. However, percutaneous coronary intervention with stent implantation (PCI) has more recently emerged as a valuable alternative. The long-time awaited results of the largest randomized trials on the long-term impact of PCI versus CABG in LMCA disease, the newly published NOBLE and EXCEL studies, revealed contrasting results. Thus, aim of the present meta-analysis was to review the most robust evidence from randomized comparisons of CABG versus PCI for revascularization of LMCA. Randomized studies comparing long-term clinical outcomes of CABG or Stent-PCI for the treatment of LMCA disease were searched for in PubMed, the Chochrane Library and Scopus electronic databases. A total of 5 randomized studies were selected, including 4499 patients. No significant difference between CABG and PCI was found in the primary analysis on the composite endpoint of death, stroke and myocardial infarction (OR = 1·06 95% CI 0·80-1·40; p = 0·70). Similarly, no differences were observed between CABG and PCI for all-cause death (OR = 1·03 95% CI 0·81-1·32; p = 0·81). Although not statistically significant, a lower rate of stroke was registered in the PCI arm (OR = 0·86; p = 0·67), while a lower rate of myocardial infarction was found in the CABG arm (OR = 1·43; p = 0·17). On the contrary, a significantly higher rate of repeat revascularization was registered in the PCI arm (OR = 1·76 95% CI 1·45-2·13; p PCI and CABG for the treatment of LMCA disease in the composite endpoint of death, stroke and myocardial infarction. Hence, a large part of patients with unprotected left main coronary artery disease can be managed equally well by means of both these revascularization strategies.

  8. Evaluation of Silicone as an Endovascular Stent Membrane: In Vivo Canine Studies

    International Nuclear Information System (INIS)

    Fontaine, Arthur B.; Borsa, John J.; Hoffer, Eric; Bloch, Robert; So, Corali

    2001-01-01

    Purpose: Comparative evaluation of the biological effects of a silicone-covered stent versus a bare-metal stent, in an animal model.Methods: Twelve stent implants were placed in the iliac arteries of six adult dogs. Each animal received one 8-mm x 20-mm silicone-covered stent (Permalume; Boston Scientific Vascular, Watertown, MA, USA), in the right iliac artery and one Wallstent (Boston Scientific Vascular) of the same diameter and length in the left iliac artery, during systemic anticoagulation. Angiography was performed before and after implantations. Animals were then allowed to recover and no platelet suppression was given during a 6-week interval, after which the animals were euthanized. The stented arteries were isolated and pressure-fixed in situ with 10% buffered formalin at a pressure of approximately 100 mmHg for a period of 1 hr. Two of 12 stented specimens were opened lengthwise and the luminal surfaces were photographed. Ten of 12 stented arterial segments were encased in methacrylate, then stained with hematoxylin and eosin. Neointimal thickness was quantified on histologic cross-section, for both bare and covered stents. The mean neointimal thicknesses were compared for significant difference using a student t-test.Results: All implants were widely patent at 6-week follow-up angiography. Histologic analysis showed bare metal stents covered by a thin uniform lining of neointima composed of smooth muscle cells in a hyaline matrix (mean thickness of 189 ± 47 μm). Silicone covered stents were devoid of neointima. There was no chronic thrombus or mature endothelium noted anywhere upon the internal silicone surfaces of any of the specimens. There was no foreign body reaction to the silicone cover.Conclusion: Short-term implantation of a silicone-lined Wallstent in canine iliac arteries is well tolerated. Silicone appears to be inert at 6 weeks in this experimental application

  9. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis.

    Science.gov (United States)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-11-04

    To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; Pstents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. © Valgimigli et al 2014.

  10. CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kuya, Keita; Shinohara, Yuki; Fujii, Shinya; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological Therapeutic Science, Faculty of Medicine, Yonago (Japan); Sakamoto, Makoto; Watanabe, Takashi [Tottori University, Division of Neurosurgery, Department of Brain and Neurosciences, Faculty of Medicine, Yonago (Japan); Iwata, Naoki; Kishimoto, Junichi [Tottori University, Division of Clinical Radiology Faculty of Medicine, Yonago (Japan); Kaminou, Toshio [Osaka Minami Medical Center, Department of Radiology, Osaka (Japan)

    2014-11-15

    Follow-up CT angiography (CTA) is routinely performed for post-procedure management after carotid artery stenting (CAS). However, the stent lumen tends to be underestimated because of stent artifacts on CTA reconstructed with the filtered back projection (FBP) technique. We assessed the utility of new iterative reconstruction techniques, such as adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR), for CTA after CAS in comparison with FBP. In a phantom study, we evaluated the differences among the three reconstruction techniques with regard to the relationship between the stent luminal diameter and the degree of underestimation of stent luminal diameter. In a clinical study, 34 patients who underwent follow-up CTA after CAS were included. We compared the stent luminal diameters among FBP, ASIR, and MBIR, and performed visual assessment of low attenuation area (LAA) in the stent lumen using a three-point scale. In the phantom study, stent luminal diameter was increasingly underestimated as luminal diameter became smaller in all CTA images. Stent luminal diameter was larger with MBIR than with the other reconstruction techniques. Similarly, in the clinical study, stent luminal diameter was larger with MBIR than with the other reconstruction techniques. LAA detectability scores of MBIR were greater than or equal to those of FBP and ASIR in all cases. MBIR improved the accuracy of assessment of stent luminal diameter and LAA detectability in the stent lumen when compared with FBP and ASIR. We conclude that MBIR is a useful reconstruction technique for CTA after CAS. (orig.)

  11. CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction

    International Nuclear Information System (INIS)

    Kuya, Keita; Shinohara, Yuki; Fujii, Shinya; Ogawa, Toshihide; Sakamoto, Makoto; Watanabe, Takashi; Iwata, Naoki; Kishimoto, Junichi; Kaminou, Toshio

    2014-01-01

    Follow-up CT angiography (CTA) is routinely performed for post-procedure management after carotid artery stenting (CAS). However, the stent lumen tends to be underestimated because of stent artifacts on CTA reconstructed with the filtered back projection (FBP) technique. We assessed the utility of new iterative reconstruction techniques, such as adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR), for CTA after CAS in comparison with FBP. In a phantom study, we evaluated the differences among the three reconstruction techniques with regard to the relationship between the stent luminal diameter and the degree of underestimation of stent luminal diameter. In a clinical study, 34 patients who underwent follow-up CTA after CAS were included. We compared the stent luminal diameters among FBP, ASIR, and MBIR, and performed visual assessment of low attenuation area (LAA) in the stent lumen using a three-point scale. In the phantom study, stent luminal diameter was increasingly underestimated as luminal diameter became smaller in all CTA images. Stent luminal diameter was larger with MBIR than with the other reconstruction techniques. Similarly, in the clinical study, stent luminal diameter was larger with MBIR than with the other reconstruction techniques. LAA detectability scores of MBIR were greater than or equal to those of FBP and ASIR in all cases. MBIR improved the accuracy of assessment of stent luminal diameter and LAA detectability in the stent lumen when compared with FBP and ASIR. We conclude that MBIR is a useful reconstruction technique for CTA after CAS. (orig.)

  12. Palliative radiotherapy in addition to self-expanding metal stent for improving dysphagia and survival in advanced oesophageal cancer (ROCS: Radiotherapy after Oesophageal Cancer Stenting): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Adamson, Douglas; Blazeby, Jane; Nelson, Annmarie; Hurt, Chris; Nixon, Lisette; Fitzgibbon, Jim; Crosby, Tom; Staffurth, John; Evans, Mim; Kelly, Noreen Hopewell; Cohen, David; Griffiths, Gareth; Byrne, Anthony

    2014-10-22

    The single most distressing symptom for patients with advanced esophageal cancer is dysphagia. Amongst the more effective treatments for relief of dysphagia is insertion of a self-expanding metal stent (SEMS). It is possible that the addition of a palliative dose of external beam radiotherapy may prolong the relief of dysphagia and provide additional survival benefit. The ROCS trial will assess the effect of adding palliative radiotherapy after esophageal stent insertion. The study is a randomized multicenter phase III trial, with an internal pilot phase, comparing stent alone versus stent plus palliative radiotherapy in patients with incurable esophageal cancer. Eligible participants are those with advanced esophageal cancer who are in need of stent insertion for primary management of dysphagia. Radiotherapy will be administered as 20 Gray (Gy) in five fractions over one week or 30 Gy in 10 fractions over two weeks, within four weeks of stent insertion. The internal pilot will assess rates and methods of recruitment; pre-agreed criteria will determine progression to the main trial. In total, 496 patients will be randomized in a 1:1 ratio with follow up until death. The primary outcome is time to progression of patient-reported dysphagia. Secondary outcomes include survival, toxicity, health resource utilization, and quality of life. An embedded qualitative study will explore the feasibility of patient recruitment by examining patients' motivations for involvement and their experiences of consent and recruitment, including reasons for not consenting. It will also explore patients' experiences of each trial arm. The ROCS study will be a challenging trial studying palliation in patients with a poor prognosis. The internal pilot design will optimize methods for recruitment and data collection to ensure that the main trial is completed on time. As a pragmatic trial, study strengths include collection of all follow-up data in the usual place of care, and a focus on

  13. Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis: 3-Year Follow-Up of the RIBS V Clinical Trial.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; Otaegui, Imanol; Masotti, Mónica; Zueco, Javier; Veláquez, Maite; Sanchís, Juan; García-Touchard, Arturo; Lázaro-García, Rosa; Moreu, José; Bethencourt, Armando; Cuesta, Javier; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-06-27

    The aim of this study was to compare the long-term efficacy of everolimus-eluting stents (EES) and drug-eluting balloons (DEB) in patients with bare-metal stent in-stent restenosis (ISR). The relative long-term clinical efficacy of current therapeutic modalities in patients with ISR remains unknown. The 3-year clinical follow-up (pre-specified endpoint) of patients included in the RIBS V (Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent Implantation) randomized clinical trial was analyzed. All patients were followed yearly using a pre-defined structured questionnaire. A total of 189 patients with bare-metal stent ISR were allocated to either EES (n = 94) or DEB (n = 95). Clinical follow-up at 1, 2, and 3 years was obtained in all patients (100%). Compared with patients treated with DEB, those treated with EES obtained better angiographic results, including larger minimal luminal diameter at follow-up (primary study endpoint; 2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm; p 1 year) target vessel (3 [3.2%] vs. 3 [3.2%]; p = 0.95) and target lesion (1 [1%] vs. 2 [2.1%]; p = 0.54) revascularization was low and similar in the 2 arms. Rates of definite or probable stent thrombosis (1% vs. 0%) were also similar in the 2 arms. The 3-year clinical follow-up of the RIBS V clinical trial confirms the sustained safety and efficacy of EES and DEB in patients treated for bare-metal stent ISR. In this setting, EES reduce the need for target lesion revascularization at very long-term follow-up. (RIBS V [Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent] [RIBS V]; NCT01239953). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Hybrid treatment of tandem, common carotid/innominate artery and ipsilateral carotid bifurcation stenoses by simultaneous, retrograde proximal stenting and eversion carotid endarterectomy: Preliminary results of a case series.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Pasqua, Rocco; Frezzotti, Francesca; Palumbo, Piergaspare; Macrina, Francesco; Calio', Francesco

    2018-04-01

    Tandem stenoses of the internal carotid artery (ICA) and proximal, ipsilateral common carotid artery (CCA) or innominate artery can be treated with a hybrid approach, combining conventional carotid endarterectomy (CEA) and retrograde stenting of the proximal stenosis, through surgical exposure of the carotid bifurcation. The purpose of this study was to evaluate the results of combining eversion CEA with retrograde CCA/innominate artery stenting. From January 2015 to July 2017, 7 patients, 6 men of a mean age of 72 years (range 59-83 years) underwent simultaneous, retrograde stenting of the proximal CCA/innominate artery and an eversion CEA of the ipsilateral ICA, through surgical exposure of the carotid bifurcation, for severe tandem stenoses. The proximal stenosis involved the left proximal CCA in 4 patients, the proximal innominate artery in 2 patients and the right CCA in one patient. The procedure was performed under general anesthesia in a conventional operating room equipped with a mobile C-arm. A covered, balloon expandable stent was deployed over the proximal stenosis via a 6-F sheath directly introduced into the proximal CCA through the obliquely transected carotid bulb. After removing the sheath, debris were flushed through the carotid bulb and eversion CEA completed the procedure. Study endpoints were: postoperative stroke/mortality rate, cardiac mortality and morbidity, peripheral nerve injury, cervical hematoma, overall late survival, freedom from ipsilateral stroke and patency of arterial reconstruction. No postoperative mortality or neurologic morbidity was observed in any patient. Cervical hematomas and peripheral nerve injuries were likewise absent. At a mean follow-up of 18 months, all the patients were alive, free from neurologic events of new onset and free from restenosis. Combined proximal stenting and eversion CEA for tandem lesions seems a valid treatment, with the advantages of eversion CEA over other techniques of carotid bifurcation

  15. Direct implantation of rapamycin-eluting stents with bioresorbable drug carrier technology utilising the Svelte coronary stent-on-a-wire: the DIRECT II study.

    Science.gov (United States)

    Verheye, Stefan; Khattab, Ahmed A; Carrie, Didier; Stella, Pieter; Slagboom, Ton; Bartunek, Jozef; Onuma, Yoshinobu; Serruys, Patrick W

    2016-08-05

    Our aim was to demonstrate the safety and efficacy of the Svelte sirolimus-eluting coronary stent-on-a-wire Integrated Delivery System (IDS) with bioresorbable drug coating compared to the Resolute Integrity zotarolimus-eluting stent with durable polymer in patients with de novo coronary artery lesions. Direct stenting, particularly in conjunction with transradial intervention (TRI), has been associated with reduced bleeding complications, procedure time, radiation exposure and contrast administration compared to conventional stenting with wiring and predilatation. The low-profile Svelte IDS is designed to facilitate TRI and direct stenting, reducing the number of procedural steps, time and cost associated with coronary stenting. DIRECT II was a prospective, multicentre trial which enrolled 159 patients to establish non-inferiority of the Svelte IDS versus Resolute Integrity using a 2:1 randomisation. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Target vessel failure (TVF), as well as secondary clinical endpoints, will be assessed annually up to five years. At six months, in-stent LLL was 0.09±0.31 mm in the Svelte IDS group compared to 0.13±0.27 mm in the Resolute Integrity group (p<0.001 for non-inferiority). TVF at one year was similar across the Svelte IDS and Resolute Integrity groups (6.5% vs. 9.8%, respectively). DIRECT II demonstrated the non-inferiority of the Svelte IDS to Resolute Integrity with respect to in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.

  16. Coronary Artery Stent Evaluation Using a Vascular Model at 64-Detector Row CT: Comparison between Prospective and Retrospective ECG-Gated Axial Scans

    International Nuclear Information System (INIS)

    Suzuki, Shigeru; Furui, Shigeru; Kaminaga, Tatsuro; Miyazawa, Akiyoshi; Ueno, Yasunari; Konno, Kumiko; Kuwahara, Sadatoshi; Mehta, Dhruv

    2009-01-01

    We wanted to evaluate the performance of prospective electrocardiogram (ECG)-gated axial scans for assessing coronary stents as compared with retrospective ECG-gated helical scans. As for a vascular model of the coronary artery, a tube of approximately 2.5-mm inner diameter was adopted and as for stents, three (Bx-Velocity, Express2, and Micro Driver) different kinds of stents were inserted into the tube. Both patent and stenotic models of coronary artery were made by instillating different attenuation (396 vs. 79 Hounsfield unit [HU]) of contrast medium within the tube in tube model. The models were scanned with two types of scan methods with a simulated ECG of 60 beats per minute and using display field of views (FOVs) of 9 and 18 cm. We evaluated the in-stent stenosis visually, and we measured the attenuation values and the diameter of the patent stent lumen. The visualization of the stent lumen of the vascular models was improved with using the prospective ECG-gated axial scans and a 9-cm FOV. The inner diameters of the vascular models were underestimated with mean measurement errors of -1.10 to -1.36 mm. The measurement errors were smaller with using the prospective ECG-gated axial scans (Bx-Velocity and Express2, p < 0.0001; Micro Driver, p = 0.0004) and a 9-cm FOV (all stents: p < 0.0001), as compared with the other conditions, respectively. The luminal attenuation value was overestimated in each condition. For the luminal attenuation measurement, the use of prospective ECG-gated axial scans provided less measurement error compared with the retrospective ECG-gated helical scans (all stents: p < 0.0001), and the use of a 9-cm FOV tended to decrease the measurement error. The visualization of coronary stents is improved by the use of prospective ECG-gated axial scans and using a small FOV with reduced blooming artifacts and increased spatial resolution

  17. Drug-eluting stents versus bare-metal stents for acute coronary syndrome

    DEFF Research Database (Denmark)

    Feinberg, Joshua; Nielsen, Emil Eik; Greenhalgh, Janette

    2017-01-01

    -EXPANDED, and BIOSIS from their inception to January 2017. We also searched two clinical trials registers, the European Medicines Agency and the US Food and Drug Administration databases, and pharmaceutical company websites. In addition, we searched the reference lists of review articles and relevant trials. SELECTION...... CRITERIA: Randomised clinical trials assessing the effects of drug-eluting stents versus bare-metal stents for acute coronary syndrome. We included trials irrespective of publication type, status, date, or language. DATA COLLECTION AND ANALYSIS: We followed our published protocol and the methodological...

  18. Vascular stents: Coupling full 3-D with reduced-order structural models

    International Nuclear Information System (INIS)

    Avdeev, I; Shams, M

    2010-01-01

    Self-expanding nitinol stents are used to treat peripheral arterial disease. The peripheral arteries are subjected to a combination of mechanical forces such as compression, torsion, bending, and contraction. Most commercially available peripheral self-expanding stents are composed of a series of sub-millimeter V-shaped struts, which are laser-cut from a nitinol tube and surface-treated for better fatigue performance. The numerical stent models must accurately predict location and distribution of local stresses and strains caused by large arterial deformations. Full 3-D finite element non-linear analysis of an entire stent is computationally expensive to the point of being prohibitive, especially for longer stents. Reduced-order models based on beam or shell elements are fairly accurate in capturing global deformations, but are not very helpful in predicting stent failure. We propose a mixed approach that combines the full 3-D model and reduced-order models. Several global-local, full 3-D/reduced-order finite element models of a peripheral self-expanding stent were validated and compared with experimental data. The kinematic constraint method used to couple various elements together was found to be very efficient and easily applicable to commercial FEA codes. The proposed mixed models can be used to accurately predict stent failure based on realistic (patient-specific), non-linear kinematic behavior of peripheral arteries.

  19. Safety analysis of Wingspan stent angioplasty for symptomatic intracranial arterial stenosis: A report of 109 cases

    Directory of Open Access Journals (Sweden)

    Jian-ping DENG

    2011-12-01

    Full Text Available Objective The present study aims to probe into the feasibility and safety of larger balloons in the self-expandable stent Wingspan system when treating symptomatic intracranial arterial stenosis.Methods The clinical data of 109 symptomatic intracranial arterial stenosis patients,consisting of 68 males and 41 females,were analyzed.These patients were treated via angioplasty using the Wingspan system from March 2007 to June 2010.The ages of the patients ranged from 36 years to 79 years,with an average of 62.4.The patients were divided into two groups according to the sizes of the Gateway balloons they used.The balloon diameter for group A(n=31 was based on 80% of the diameter of the normal blood vessels on both sides of the arterial vessel.Meanwhile,the balloon diameter for group B was based on the average diameter of the vessels on both sides of the arterial vessel.The effects of the treatment and the occurrence of complications in both groups were analyzed and compared.Results The degree of arteriostenosis before operation for group A was 56.0% to 87.8%,with an average of 71.8%,residual stenosis after operation was 0% to 45%,with an average of 24.9%.The degree of ateriostenosis before operation for group B was 68.9% to 98.0%,with an average of 76.0%,residual stenosis after operation was 0% to 21%,with an average of 10.2%.Group A had four cases(12.9% of durability neurological dysfunction.One case was a visual-field defect.In group B,six patients(7.7% experienced complications.The differences were not statistically significant,and no deaths occurred in both groups.Conclusions Wingspan stent angioplasty is a safe and effective treatment for intracranial arterial stenosis,and even the use of larger balloons does not increase the risk in patients.

  20. The Effect of Stent Cell Geometry on Carotid Stenting Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Alparslan, Burcu, E-mail: burcu.alparslan@gmail.com [Yozgat State Hospital, Radiology Clinic (Turkey); Nas, Omer Fatih, E-mail: omerfatihnas@gmail.com [Uludag University Faculty of Medicine, Department of Radiology (Turkey); Eritmen, Ulku Turpcu, E-mail: drulkutur@hotmail.com.tr [Special Eregli Anatolia Hospital, Radiology Clinic (Turkey); Duran, Selcen, E-mail: selcenduran16@hotmail.com [Yerkoy State Hospital, Neurology Clinic (Turkey); Ozkaya, Guven, E-mail: ozkaya@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Biostatistics (Turkey); Hakyemez, Bahattin, E-mail: bhakyemez@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Radiology (Turkey)

    2016-04-15

    PurposeThe aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).Materials and MethodOne hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.ResultsEleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3 % (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.ConclusionIn-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if ‘possible’, no difference was detected in terms of clinical outcomes.

  1. Supera self-expanding stents for endovascular treatment of femoropopliteal disease: a review of the clinical evidence

    Directory of Open Access Journals (Sweden)

    Bishu K

    2015-07-01

    Full Text Available Kalkidan Bishu,1,2 Ehrin J Armstrong1,21Division of Cardiology, University of Colorado, Aurora, 2Denver VA Medical Center, Denver, CO, USAAbstract: Femoropopliteal lesions account for a significant proportion of endovascular interventions for peripheral artery disease in patients with disabling claudication or chronic limb ischemia. The femoropopliteal artery crosses two joint structures (hip and knee joints and courses through the muscular adductor canal in the thigh, which places the artery at increased biomechanical stress. There is a critical need for stent platforms with a reduced risk of stent fracture while maintaining patency during long-term follow-up. The Supera peripheral stent system has a braided nickel–titanium alloy stent designed to withstand the unique stressors along the course of the femoropopliteal artery. This design may be associated with improved patency in association with reduced stent fracture rates on short- and medium-term follow-up. Further studies, including randomized controlled studies, comparing the Supera interwoven nickel–titanium alloy stent system with other stent platforms and angioplasty alone are needed.Keywords: peripheral artery disease, femoropopliteal atherosclerosis, SUPERA interwoven nitinol stent, stent fracture

  2. Lateral abdominal wall hematoma as a rare complication after carotid artery stenting: a case report

    Directory of Open Access Journals (Sweden)

    Satomi Jyunichiro

    2009-11-01

    Full Text Available Abstract Abdominal wall hematoma is a rare and life-threatening complication after carotid artery stenting (CAS, but it can occur when activated clotting time is prolonged. We report a right lateral abdominal wall hematoma caused by rupture of the superficial circumflex iliac artery after CAS in a 72-year-old man with severe stenosis of the origin of the right internal carotid artery. We performed CAS for the targeted lesion while activated clotting time exceeded 300 seconds. After 2 hours, he complained of right lateral abdominal pain. Abdominal computed tomography revealed an extensive hematoma in the right lateral abdominal wall. Activated clotting time was 180 seconds at this point. Seven hours later, he developed hypotension and hemoglobin level dropped to 11.3 g/dl. Subsequent computed tomography showed enlargement of the hematoma. Emergent selective angiography of the external iliac artery revealed active bleeding from the right superficial circumflex iliac artery. Transcatheter arterial embolization with Gelfoam and microcoils was performed successfully. With more CAS procedures being performed, it is important for endovascular surgeons and radiologists to consider the possibility of abdominal wall hematoma in this situation.

  3. Juxtarenal Modular Aortic Stent Graft Infection Caused by Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    Róbert Novotný

    2016-01-01

    Full Text Available Introduction. We are presenting a case report of an infected modular abdominal stent graft. Case Presentation. A 67-year-old male patient three years after Cook’s modular abdominal aortic aneurysm (AAA graft implantation for juxtarenal AAA with an implantation of a stent extension into the right common iliac artery for type Ib endoleak. The patient was admitted into our center in severe condition with suspected retroperitoneal bleeding. Computed tomography angiography (CTAG confirmed retroperitoneal bleeding in the right common iliac artery. An urgent surgical revision was indicated; destructed arterial wall around the stent extension in the right common iliac artery was discovered. Due to the severe state of health of the patient, a resection of the infected stent and affected arterial wall was performed, followed by an iliac-femoral crossover bypass. The patient was transported to the intensive care unit with hepatic and renal failure, with maximal catecholamine support. Combined antibiotic treatment was started. The patient died five hours after the procedure. The cause of death was multiorgan failure caused by sepsis. Hemocultures and perioperative microbiological cultures showed the infection agent to be Staphylococcus aureus methicillin sensitive. Conclusion. Stent graft infection is a rare complication. Treatment is associated with high mortality and morbidity.

  4. Angioplasty treatment and stent implant vs. surgical treatment in patients with stenosis of the cervical carotid artery

    International Nuclear Information System (INIS)

    Hamdan, Nabil; Castro, Pablo; Calderon, Luis I; Gomez, German; Estrada, Gilberto; Hurtado, Edgar; Echeverria, Rene

    2006-01-01

    Angioplasty with stent implant is a less invasive procedure than surgical intervention in the treatment of significant stenosis of the common cervical carotid artery (common and internal) (5). Currently the major published studies, in which angioplasty and surgical treatment are compared, show similar results in the major events, as cerebrovascular accidents and mortality, but a greater significant difference in the apparition of acute myocardial infarction, during surgical intervention (5,11). The objective of this study is to compare in both treatment methods the major and minor clinical events, like cerebrovascular accident, acute myocardial infarction, death, bradycardia, hypotension and encephalopathy during the intervention, the hospitalization and the follow-up year, as well as the re-intervention, the time of hospital stay and the complications of the surgical incision. Materials and methods: in this study of historical cohort, 46 patients with significant stenosis of the cervical carotid arteries, who were subjected to intervention from January 1st 2001 to December 31st 2003, were included. 21 patients were treated with angioplasty and stent implant and 25 with surgery (endarterectomy) Results: 1 (4.8%) major cerebrovascular accident occurred during angioplasty, whereas none occurred in the patients treated with surgery. 1 (4%) acute myocardial infarction occurred during intervention in the group of patients treated with surgery, and none in the patients treated with angioplasty. No deaths occurred in any of the groups during intervention, hospitalization and the follow-up year. After 8 months 1 (4%) patient treated with surgery was intervened again with angioplasty and stent implant. There were no statistically significant differences between both groups during hospitalization, and in the apparition of minor complications as bradycardia and hypotension. 2 (8%) complications related to the incision of the neck compromising cranial nerves, occurred in the

  5. [Comparison of efficacy and safety of treatment with drugs of clopidogrel in patients after coronary artery stenting].

    Science.gov (United States)

    Avdeeva, L V; Shtegman, O A; Mosina, V A

    2011-01-01

    Proof of clinical equivalence of generic and original dugs - the way to lessen cost of therapy of patients while providing comparable clinical effects. We present in this paper results of 1 year follow-up of 115 patients receiving Egithromb or Plavics after coronary artery stenting. Comparable clinical efficacy and safety of Egithromb and Plavics has been established.

  6. Correlation of Admission Heart Rate With Angiographic and Clinical Outcomes in Patients With Right Coronary Artery ST-Segment Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention: HORIZONS-AMI (The Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) Trial.

    Science.gov (United States)

    Kosmidou, Ioanna; McAndrew, Thomas; Redfors, Björn; Embacher, Monica; Dizon, José M; Mehran, Roxana; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W

    2017-07-19

    Bradycardia on presentation is frequently observed in patients with right coronary artery ST-segment elevation myocardial infarction, but it is largely unknown whether it predicts poor angiographic or clinical outcomes in that patient population. We sought to determine the prognostic implications of admission heart rate (AHR) in patients with ST-segment elevation myocardial infarction and a right coronary artery culprit lesion. We analyzed 1460 patients with ST-segment elevation myocardial infarction and a right coronary artery culprit lesion enrolled in the randomized HORIZONS-AMI (Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction) trial who underwent primary percutaneous coronary intervention. Patients presenting with high-grade atrioventricular block were excluded. Outcomes were examined according to AHR range (AHR 100 beats per minute). Angiographic analysis showed no significant association between AHR and lesion location or complexity. On multivariate analysis, admission bradycardia (AHR ST-segment elevation myocardial infarction and a right coronary artery culprit lesion undergoing primary percutaneous coronary intervention, admission bradycardia was not associated with increased mortality or major adverse cardiac events at 1 year. URL: https://www.clinicaltrials.gov. Unique identifier: NCT00433966. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  7. Sirolimus-eluting versus bare-metal stent implantation in patients with ostial lesions

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Kelbæk, Henning; Kløvgaard, Lene

    2010-01-01

    To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries.......To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries....

  8. Restenosis in coronary bare metal stents. Importance of time to follow-up: a comparison of coronary angiograms 6 months and 4 years after implantation

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Helqvist, Steffen; Kløvgaard, Lene

    2008-01-01

    Objectives. Angiographic late lumen loss measured 6 to 9 month after bare metal stent implantation in the coronary arteries is a validated restenosis parameter. Design. We performed a second angiographic follow-up after 4 years in event free survivors from the DANSTENT trial cohort. Results......-sectional vessel area and a 39% reduction of the binary restenosis rate over time. Conclusions. Instent late lumen loss in bare metal stents decreases spontaneously over time. Maturation of early hyperplastic tissue reaction after stent implantation with subsequent thinning of fibrotic tissue might explain...

  9. Optimization of Drug Delivery by Drug-Eluting Stents.

    Directory of Open Access Journals (Sweden)

    Franz Bozsak

    Full Text Available Drug-eluting stents (DES, which release anti-proliferative drugs into the arterial wall in a controlled manner, have drastically reduced the rate of in-stent restenosis and revolutionized the treatment of atherosclerosis. However, late stent thrombosis remains a safety concern in DES, mainly due to delayed healing of the endothelial wound inflicted during DES implantation. We present a framework to optimize DES design such that restenosis is inhibited without affecting the endothelial healing process. To this end, we have developed a computational model of fluid flow and drug transport in stented arteries and have used this model to establish a metric for quantifying DES performance. The model takes into account the multi-layered structure of the arterial wall and incorporates a reversible binding model to describe drug interaction with the cells of the arterial wall. The model is coupled to a novel optimization algorithm that allows identification of optimal DES designs. We show that optimizing the period of drug release from DES and the initial drug concentration within the coating has a drastic effect on DES performance. Paclitaxel-eluting stents perform optimally by releasing their drug either very rapidly (within a few hours or very slowly (over periods of several months up to one year at concentrations considerably lower than current DES. In contrast, sirolimus-eluting stents perform optimally only when drug release is slow. The results offer explanations for recent trends in the development of DES and demonstrate the potential for large improvements in DES design relative to the current state of commercial devices.

  10. Single-dose brachytherapy versus metal stent placement for the palliation of dysphagia from oesophageal cancer: multicentre randomised trial

    NARCIS (Netherlands)

    Homs, Marjolein Y. V.; Steyerberg, Ewout W.; Eijkenboom, Wilhelmina M. H.; Tilanus, Hugo W.; Stalpers, Lukas J. A.; Bartelsman, Joep F. W. M.; van Lanschot, Jan J. B.; Wijrdeman, Harm K.; Mulder, Chris J. J.; Reinders, Janny G.; Boot, Henk; Aleman, Berthe M. P.; Kuipers, Ernst J.; Siersema, Peter D.

    2004-01-01

    Background Both single-dose brachytherapy and self-expanding metal stent placement are commonly used for palliation of oesophageal obstruction due to inoperable cancer, but their relative merits are unknown. We under-took a randomised trial to compare the outcomes of brachytherapy and stent

  11. Reverse waffle cone technique in management of stent dislodgement into intracranial aneurysms.

    Science.gov (United States)

    Luo, Chao-Bao; Lai, Yen-Jun; Teng, Michael Mu-Huo; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo

    2013-09-01

    Stent-assisted coil embolization (SACE) is a common method to manage intracranial wide-neck aneurysm. Using this technique, a stent must be successfully deployed into the parent artery to cross the aneurysm neck. We describe the reverse waffle cone technique in management of intra-procedural stent dislodgement during SACE of internal carotid artery (ICA) wide-neck aneurysms. Two patients with unruptured wide-neck ICA aneurysms underwent SACE. Intra-procedural forward stent migration occurred during catheterization with proximal stent dislodgement and migration into the aneurysm sac. Navigation of a second stent to bridge the aneurysm neck failed in one patient because the second stent was impeded by the dislodged stent. Using the reverse waffle cone technique, a microcatheter was navigated into the aneurysm sacs. Coils were safely detached into each aneurysm sac without any device assistance. The two wide-neck aneurysms were successfully treated with preservation of flow to the internal carotid arteries. The complication of intra-procedural distal stent migration and dislodgement, with proximal stent prolapse into an aneurysm sac, may not result in a failure to coil the aneurysm. The reverse waffle cone technique provides an effective treatment in the management of this complication. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Coronary stent on coronary CT angiography: Assessment with model-based iterative reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Chae; Kim, Yeo Koon; Chun, Eun Ju; Choi, Sang IL [Dept. of of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-05-15

    To assess the performance of model-based iterative reconstruction (MBIR) technique for evaluation of coronary artery stents on coronary CT angiography (CCTA). Twenty-two patients with coronary stent implantation who underwent CCTA were retrospectively enrolled for comparison of image quality between filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and MBIR. In each data set, image noise was measured as the standard deviation of the measured attenuation units within circular regions of interest in the ascending aorta (AA) and left main coronary artery (LM). To objectively assess the noise and blooming artifacts in coronary stent, we additionally measured the standard deviation of the measured attenuation and intra-luminal stent diameters of total 35 stents with dedicated software. All image noise measured in the AA (all p < 0.001), LM (p < 0.001, p = 0.001) and coronary stent (all p < 0.001) were significantly lower with MBIR in comparison to those with FBP or ASIR. Intraluminal stent diameter was significantly higher with MBIR, as compared with ASIR or FBP (p < 0.001, p = 0.001). MBIR can reduce image noise and blooming artifact from the stent, leading to better in-stent assessment in patients with coronary artery stent.

  13. Colonic stenting as bridge to surgery versus emergency surgery for management of acute left-sided malignant colonic obstruction: a multicenter randomized trial (Stent-in 2 study

    Directory of Open Access Journals (Sweden)

    Scholten Pieter

    2007-07-01

    analysis of variance. Mortality will be compared using Kaplan-Meier curves and log-rank statistics. Discussion The Stent-in 2 study is a randomized controlled multicenter trial that will provide evidence whether or not colonic stenting as bridge to surgery is to be performed in patients with acute left-sided colonic obstruction. Trial registration Current Controlled Trials ISRCTN46462267.

  14. Long-Term Results after Placement of Aortic Bifurcation Self-Expanding Stents: 10 Year Mortality, Stent Restenosis, and Distal Disease Progression

    International Nuclear Information System (INIS)

    Houston, J. Graeme; Bhat, Raj; Ross, Rose; Stonebridge, Peter A.

    2007-01-01

    Purpose. To retrospectively evaluate the 10 year follow-up results in patients who had 'kissing' self-expanding stent aortic bifurcation reconstruction. Methods. Forty-three patients were treated with 'kissing' self-expanding stents for aortoiliac occlusive disease. Early follow-up with clinical and ankle brachial pressure indices (ABPI) was performed at 3, 6, 12, and 24 months and with intra-arterial digital subtraction angiography at 12-24 months; clinical and angiographic follow-up was performed for symptom recurrence up to 10 years after treatment. Retrospective record review was performed to assess mortality, clinical patency, angiographic patency, and secondary assisted patency of both stents and downstream peripheral vessels at 5 and 10 years follow-up. Results. The 2 year primary angiographic and secondary assisted stent patencies were 89% and 93%, respectively. At 10 years follow-up in 40 patients the mortality was 38% (due to myocardial infarction, stroke, chronic renal failure, malignancy, and liver failure). At 5 and 10 years follow-up the primary clinical stent patency was 82% and 68%, and the secondary assisted stent patency 93% and 86%, respectively. At 5 and 10 years, the distal vessel patency was 86% and 72%, and the secondary assisted distal vessel patency treated by surgical or endovascular techniques was 94% and 88%, respectively. At 10 years there was no limb loss. Conclusion. The long-term (10 year) results of aortic bifurcation arterial self-expanding stent placement in patients with arterial occlusive disease show a 10 year primary stent patency rate of 68% but a secondary assisted patency rate of 86%. In addition there is a high overall mortality due to other cardiovascular causes and the rate of distal disease progression and loss of patency is similar to the loss of stent patency rate

  15. Application of the Enterprise Stent in Atherosclerotic Intracranial Arterial Stenosis: A Series of 60 Cases.

    Science.gov (United States)

    Wang, Xiaofei; Wang, Zhigang; Wang, Chengwei; Ji, Yong; Ding, Xuan; Zang, Yizheng

    2016-01-01

    We assessed the safety and effectiveness of the Enterprise stent in treating atherosclerotic intracranial arterial stenosis (AIAS). This was a retrospective study conducted with 60 consecutive patients with 62 AIAS lesions who received the Enterprise stent at the Department of Neurosurgery, Second Hospital of Shandong University between June 2012 and January 2014. All patients were assessed using the modified Rankin scoring system at discharge. Clinical follow-ups and digital subtraction angiography (DSA) were performed at 1, 3, 6 and 12 months postoperatively. There were 42 men and 18 women with a mean age of 56.8 ± 8.0 years. Fourteen lesions (22.6%) were at the anterior and 48 (77.4 %) were at the posterior circulation. The mean stenosis rate was 76.3 ± 12.7%. The mean stenotic vessel length was 7.7 ± 2.0 mm. The technical success rate was 100%. The mean post-stent residual stenosis rate was 22.8 ± 4.8%. Five patients (8.3%) had perioperative complications, but no disability or mortality occurred within 30 days. The mean follow-up duration was 6.2 months. DSA was used to evaluate 45 lesions (72.6%) six months postoperatively: 6 (13.3%) had postoperative restenoses, 2 at the anterior circulation, and 4 at the posterior circulation. Of these 6, 4 (66.7%) were immediate residual stenoses after stenting. The residual stenosis rate was identified as a risk factor for restenosis. Five (8.3%) ischemic events, consistent with the vascular lesions, occurred. Application of the Enterprise stent was safe and efficacious. The technical success rate was high while the perioperative complication rate was low.

  16. Covered stent to exclude intravascular thrombus.

    Science.gov (United States)

    Liistro, Francesco; Stankovic, Goran; Di Mario, Carlo; Montorfano, Matteo; Briguori, Carlo; Colombo, Antonio

    2002-04-01

    To describe the utility of stent-graft implantation to avoid distal embolization from a large thrombus-containing lesion. A 67-year-old man was evaluated for recent onset of disabling left leg claudication. Angiography disclosed a mobile lobular mass occluding the left common iliac artery; irregular staining suggested an atherothrombotic lesion. Through a percutaneous ipsilateral access and an 8-F sheath, a balloon-expandable Jostent peripheral stent-graft was positioned with the distal edge immediately proximal to the internal iliac artery ostium. A prominent "waist" at the center of the balloon confirmed entrapment of the thrombotic mass. Completion angiography showed an optimal result with no residual stenosis or evidence of distal embolization. At 6-month follow-up, the patient was asymptomatic with angiographically documented luminal patency and no evidence of in-stent stenosis. Stent-graft implantation appears a viable treatment alternative for thrombus-containing lesions, particularly when the thrombotic material is localized or is in a large vessel.

  17. Waves and fluid-solid interaction in stented blood vessels

    Science.gov (United States)

    Frecentese, S.; Argani, L. P.; Movchan, A. B.; Movchan, N. V.; Carta, G.; Wall, M. L.

    2018-01-01

    This paper focuses on the modelling of fluid-structure interaction and wave propagation problems in a stented artery. Reflection of waves in blood vessels is well documented in the literature, but it has always been linked to a strong variation in geometry, such as the branching of vessels. The aim of this work is to detect the possibility of wave reflection in a stented artery due to the repetitive pattern of the stents. The investigation of wave propagation and possible blockages under time-harmonic conditions is complemented with numerical simulations in the transient regime.

  18. Antirestenotic Effects of a Novel Polymer-Coated D-24851 Eluting Stent. Experimental Data in a Rabbit Iliac Artery Model

    International Nuclear Information System (INIS)

    Lysitsas, Dimitrios N.; Katsouras, Christos S.; Papakostas, John C.; Toumpoulis, Ioannis K.; Angelidis, Charalampos; Bozidis, Petros; Thomas, Christopher G.; Seferiadis, Konstantin; Psychoyios, Nikolaos; Frillingos, Stathis; Pavlidis, Nikolaos; Marinos, Euaggelos; Khaldi, Lubna; Sideris, Dimitris A.; Michalis, Lampros K.

    2007-01-01

    Experimental and clinical data suggest that stents eluting antiproliferative agents can be used for the prevention of in-stent restenosis. Here we investigate in vitro the antiproliferative and apoptotic effect of D-24851 and evaluate the safety and efficacy of D-24851-eluting polymer-coated stents in a rabbit restenosis model (n = 53). Uncoated stents (n = 6), poly (dl-lactide-co-glycolide) (PLGA)-coated stents (n = 7), and PLGA-coated stents loaded with 0.08 ± 0.0025 μM (31 ± 1 μg; low dose; n = 7), 0.55 ± 0.02 μM (216 ± 8 μg; high dose; n = 6), and 4.55 ± 0.1 μM (1774 ± 39 μg; extreme dose; n = 5) of D-24851 were randomly implanted in New Zealand rabbit right iliac arteries and the animals were sacrificed after 28 days for histomorphometric analysis. For the assessment of endothelial regrowth in 90 days, 12 rabbits were subjected to PLGA-coated (n = 3), low-dose (n = 3), high-dose (n = 3), and extreme-dose (n = 3) stent implantation. In vitro studies revealed that D-24851 exerts its growth inhibitory effects via inhibition of proliferation and induction of apoptosis without increasing the expression of heat shock protein-70, a cytoprotective and antiapoptotic protein. Treatment with low-dose D-24851 stents was associated with a significant reduction in neointimal area and percentage stenosis only compared with bare metal stents (38% [P = 0.029] and 35% [P = 0.003] reduction, respectively). Suboptimal healing, however, was observed in all groups of D-24851-loaded stents in 90 days in comparison with PLGA-coated stents. We conclude that low-dose D-24851-eluting polymer-coated stents significantly inhibit neointimal hyperplasia at 28 days through inhibition of proliferation and enhancement of apoptosis. In view of the suboptimal re-endothelialization, longer-term studies are needed in order to establish whether the inhibition of intimal growth is maintained

  19. Treatment of a spontaneous intracranial dissecting aneurysm with stent-assisted coil embolization

    International Nuclear Information System (INIS)

    Irie, Keiko; Negoro, Makoto; Hayakawa, Motoharu; Hayashi, Junichi; Kanno, Tetsuo

    2003-01-01

    Arterial dissection is now recognized as an important cause of stroke. Most reported dissections involve the extracranial portion of the internal carotid artery (ICA) and vertebral arteries. Spontaneous dissecting aneurysms of the intracranial ICA are uncommon. Endovascular treatment for cerebral aneurysms has become widespread; however, the dissecting aneurysm is still difficult to treat if the parent artery has to be preserved. More recently, stenting has been advocated for use with endosaccular coiling, with the coils held in place by the stent. We herein report a spontaneous intracranial ICA dissecting aneurysm in a 51-year-old woman who was treated using a new technique of combined stent and coils. (orig.)

  20. Trial of self-expandable metallic stents in the palliation of tracheo ...

    African Journals Online (AJOL)

    Trial of self-expandable metallic stents in the palliation of tracheo-oesophageal fistula in carcinoma of the oesophagus. ... Over half of the patients in the TOF group had concomitant pneumonia at presentation with decreased survival (p = 0.010) and a hazard ratio of 10.86. Two patients died, on days 4 and 7 respectively.