  1. INTRAVASCULAR ULTRASOUND EVALUATING CORONARY STENTS FOR PATIENTS WITH CORONARY ARTERY DISEASE: COMPARED OLD WITH NEW MULTILINK STENTS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Objective.It was suggested that coronary stent design and coating may affect stent performance and hence induce varying degrees of thrombogenesis and neointimal hyperplasia.The purpose of this study is to compare the 6 month follow up results between old and new Multilink stents with the method of intravascular ultrasound (IVUS) imaging.Methods.We have performed old (n=40) and new (n=35) Multilink stent implantations on 75 patients with coronary artery disease.Coronary angiography was performed before,immediately after,and 6 months after the in stent procedure respectively.Six month follow up IVUS imaging was performed and analyzed off line.Results.Minimal lumen cross sectional area (CSA) of new Multilink stents was significantly larger than that of old Multilink stents (P=0.0053).Mean stent lumen area of new Multilink stents was significantly larger than that of old Multilink stents (P=0.040).Similarly,minimal lumen diameter (MLD) of new Multilink stents was larger than that of old Multilink stents (P= 0.011).Old Multilink stents had a higher percentage of plaque area than new Multilink stents.Conclusion.The new Multilink stent is obviously superior to old Multilink stents,in particular,in the stent MLD and lumen CSA- - major determinants of the restenosis.

  2. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study) : an interim analysis of a randomised controlled trial

    NARCIS (Netherlands)

    Ederle, Joerg; Dobson, Joanna; Featherstone, Roland L.; Bonati, Leo H.; van der Worp, H. Bart; de Borst, Gert J.; Lo, T. Hauw; Gaines, Peter; Dorman, Paul J.; Macdonald, Sumaira; Lyrer, Philippe A.; Hendriks, Johanna M.; McCollum, Charles; Nederkoorn, Paul J.; Brown, Martin M.; Algra, A.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Clifton, A.; Gaines, P.; Hacke, W.; Halliday, A.; Malik, I.; Mas, J. L.; McGuire, A. J.; Sidhu, P.; Venables, G.; Bradbury, A.; Brown, M. M.; Clifton, A.; Gaines, P.; Collins, R.; Molynewc, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Bonati, L. H.; Coward, L.; Dobson, J.; Ederle, J.; Featherstone, R. F.; Tindall, H.; McCabe, D. J. H.; Wallis, A.; Brooks, M.; Chambers, B.; Chan, A.; Chu, P.; Clark, D.; Dewey, H.; Donnan, G.; Fell, G.; Hoare, M.; Molan, M.; Roberts, A.; Roberts, N.; Beiles, B.; Bladin, C.; Clifford, C.; Fell, G.; Grigg, M.; New, G.; Bell, R.; Bower, S.; Chong, W.; Holt, M.; Saunder, A.; Than, P. G.; Gett, S.; Leggett, D.; McGahan, T.; Quinn, J.; Ray, M.; Wong, A.; Woodruff, P.; Foreman, R.; Schultz, D.; Scroop, R.; Stanley, B.; Allard, B.; Atkinson, N.; Cambell, W.; Davies, S.; Field, P.; Milne, P.; Mitchell, P.; Tress, B.; Yan, B.; Beasley, A.; Dunbabin, D.; Stary, D.; Walker, S.; Cras, P.; d'Archambeau, O.; Hendriks, J. M. H.; Van Schil, P.; Bosiers, M.; Deloose, K.; van Buggenhout, E.; De Letter, J.; Devos, V.; Ghekiere, J.; Vanhooren, G.; Astarci, P.; Hammer, F.; Lacroix, V.; Peeters, A.; Verhelst, R.; DeJaegher, L.; Peeters, A.; Verbist, J.; Blair, J-F; Caron, J. L.; Daneault, N.; Giroux, M-F; Guilbert, F.; Lanthier, S.; Lebrun, L-H; Oliva, V.; Raymond, J.; Roy, D.; Soulez, G.; Weill, A.; Hill, M.; Hu, W.; Hudion, M.; Morrish, W.; Sutherland, G.; Wong, J.; Alback, A.; Harno, H.; Ijas, P.; Kaste, M.; Lepantalo, M.; Mustanoja, S.; Paananen, T.; Porras, M.; Putaala, J.; Railo, M.; Sairanen, T.; Soinne, L.; Vehmas, A.; Vikatmaa, P.; Goertler, M.; Halloul, Z.; Skalej, M.; Brennan, P.; Kelly, C.; Leahy, A.; Moroney, J.; Thornton, J.; Koelemay, M. J. W.; Nederkoorn, P. J.; Reekers, J. A. A.; Roos, Y. B. W. E. M.; Hendriks, J. M.; Koudstaal, P. J.; Pattynama, P. M. T.; van der Lugt, A.; van Dijk, L. C.; van Sambeek, M. R. H. M.; van Urk, H.; Verhagen, H. J. M.; Bruininckx, C. M. A.; de Bruijn, S. F.; Keunen, R.; Knippenberg, B.; Mosch, A.; Treurniet, F.; van Dijk, L.; van Overhagen, H.; Wever, J.; de Beer, F. C.; van den Berg, J. S. P.; van Hasselt, B. A. A. M.; Zeilstra, D. J.; Boiten, J.; van Otterloo, J. C. A. de Mol; de Vries, A. C.; Nieholt, G. J. Lycklama A.; van der Kallen, B. F. W.; Blankensteijn, J. D.; De Leeuw, F. E.; Kool, L. J. Schultze; van der Vliet, J. A.; de Borst, G. J.; de Kort, G. A. P.; Kapelle, L. J.; Lo, T. H.; Mali, W. P. Th M.; Moll, F.; van der Worp, H. Bart; Verhagen, H.; Barber, P. A.; Bourchier, R.; Hill, A.; Holden, A.; Stewart, J.; Bakke, S. J.; Krohg-Sorensen, K.; Skjelland, M.; Tennoe, B.; Bialek, P.; Biejat, Z.; Czepiel, W.; Czlonkowska, A.; Dowzenko, A.; Jedrzejewska, J.; Kobayashi, A.; Lelek, M.; Polanski, J.; Kirbis, J.; Milosevic, Z.; Zvan, B.; Blasco, J.; Chamorro, A.; Macho, J.; Obach, V.; Riambau, V.; San Roman, L.; Branera, J.; Canovas, D.; Estela, Jordi; Gimenez Gaibar, A.; Perendreu, J.; Bjorses, K.; Gottsater, A.; Ivancev, K.; Maetzsch, T.; Sonesson, B.; Berg, B.; Delle, M.; Formgren, J.; Gillgren, P.; Kall, T-B; Konrad, P.; Nyman, N.; Takolander, R.; Andersson, T.; Malmstedt, J.; Soderman, M.; Wahlgren, C.; Wahlgren, N.; Binaghi, S.; Hirt, L.; Michel, P.; Ruchat, P.; Bonati, L. H.; Engelter, S. T.; Fluri, F.; Guerke, L.; Jacob, A. L.; Kirsch, E.; Lyrer, P. A.; Radue, E-W; Stierli, P.; Wasner, M.; Wetzel, S.; Bonvin, C.; Kalangos, A.; Lovblad, K.; Murith, N.; Ruefenacht, D.; Sztajzel, R.; Higgins, N.; Kirkpatrick, P. J.; Martin, P.; Adam, D.; Bell, J.; Bradbury, A. W.; Crowe, P.; Gannon, M.; Henderson, M. J.; Sandler, D.; Shinton, R. A.; Scriven, J. M.; Wilmink, T.; D'Souza, S.; Egun, A.; Guta, R.; Punekar, S.; Seriki, D. M.; Thomson, G.; Brennan, A.; Enevoldson, T. P.; Gilling-Smith, G.; Gould, D. A.; Harris, P. L.; McWilliams, R. G.; Nasser, H-C; White, R.; Prakash, K. G.; Serracino-Inglott, F.; Subramanian, G.; Symth, J. V.; Walker, M. G.; Clarke, M.; Davis, M.; Dixit, S. A.; Dolman, P.; Dyker, A.; Ford, G.; Golkar, A.; Jackson, R.; Jayakrishnan, V.; Lambert, D.; Lees, T.; Louw, S.; Macdonald, S.; Mendelow, A. D.; Rodgers, H.; Rose, J.; Stansby, G.; Wyatt, M.; Baker, T.; Baldwin, N.; Jones, L.; Mitchell, D.; Munro, E.; Thornton, M.; Baker, D.; Davis, N.; Hamilton, G.; McCabe, D.; Platts, A.; Tibballs, J.; Beard, J.; Cleveland, T.; Dodd, D.; Gaines, P.; Lonsdale, R.; Nair, R.; Nassef, A.; Nawaz, S.; Venables, G.; Belli, A.; Clifton, A.; Cloud, G.; Halliday, A.; Markus, H.; McFarland, R.; Morgan, R.; Pereira, A.; Thompson, A.; Chataway, J.; Cheshire, N.; Gibbs, R.; Hammady, M.; Jenkins, M.; Malik, I.; Wolfe, J.; Adiseshiah, M.; Bishop, C.; Brew, S.; Brookes, J.; Brown, M. M.; Jaeger, R.; Kitchen, N.; Ashleigh, R.; Butterfield, S.; Gamble, G. E.; McCollum, C.; Nasim, A.; O'Neill, P.; Wong, J.; Edwards, R. D.; Lees, K. R.; MacKay, A. J.; Moss, J.; Rogers, P.

    2010-01-01

    Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid

  3. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2010-03-20

    Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy.

  4. Renal Artery Stent Outcomes

    Science.gov (United States)

    Murphy, Timothy P.; Cooper, Christopher J.; Matsumoto, Alan H.; Cutlip, Donald E.; Pencina, Karol M.; Jamerson, Kenneth; Tuttle, Katherine R.; Shapiro, Joseph I.; D’Agostino, Ralph; Massaro, Joseph; Henrich, William; Dworkin, Lance D.

    2016-01-01

    BACKGROUND Multiple randomized clinical trials comparing renal artery stent placement plus medical therapy with medical therapy alone have not shown any benefit of stent placement. However, debate continues whether patients with extreme pressure gradients, stenosis severity, or baseline blood pressure benefit from stent revascularization. OBJECTIVES The study sought to test the hypothesis that pressure gradients, stenosis severity, and/or baseline blood pressure affects outcomes after renal artery stent placement. METHODS Using data from 947 patients with a history of hypertension or chronic kidney disease from the largest randomized trial of renal artery stent placement, the CORAL (Cardiovascular Outcomes in Renal Atherosclerotic Lesions) study, we performed exploratory analyses to determine if subsets of patients experienced better outcomes after stent placement than the overall cohort. We examined baseline stenosis severity, systolic blood pressure, and translesion pressure gradient (peak systolic and mean) and performed interaction tests and Cox proportional hazards analyses for the occurrence of the primary endpoint through all follow-up, to examine the effect of these variables on outcomes by treatment group. RESULTS There were no statistically significant differences in outcomes based on the examined variables nor were there any consistent nonsignificant trends. CONCLUSIONS Based on data from the CORAL randomized trial, there is no evidence of a significant treatment effect of the renal artery stent procedure compared with medical therapy alone based on stenosis severity, level of systolic blood pressure elevation, or according to the magnitude of the transstenotic pressure gradient. (Benefits of Medical Therapy Plus Stenting for Renal Atherosclerotic Lesions [CORAL]; NCT00081731) PMID:26653621

  5. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial

    OpenAIRE

    Ederle, J; Dobson, J.; Featherstone, RL; Bonati, LH; van der Worp, HB; de Borst, GJ; lo, TH; Gaines, P.; Dorman, PJ; Macdonald, S; Lyrer, PA; Hendriks, JM; McCollum, C; Nederkoorn, PJ; Brown, MM

    2010-01-01

    Summary Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid Stenting Study (ICSS) is a multicentre, international, randomised controlled trial with blinded adjudication of outcomes. Patients with recently symptomatic carotid artery stenosis were ra...

  6. Preventive role of palladium-103 radioactive stent on in-stent restenosis in rabbit iliac arteries

    Institute of Scientific and Technical Information of China (English)

    LUO Quan-Yong; CHEN Li-Bo; YUAN Zhi-Bin; LU Han-Kui; ZHU Rui-Sen

    2005-01-01

    The abilility of γ-emitting palladium-103 stent implantation to inhibit in-stent restenosis in rabbit iliac arteries was investigated. Quantitative histomorphometry of the stented iliac segments 28 days after the implantation indicated that palladium-103 stents made a significant reduction in neointimal area and percent area stenosis compared with the nonradioactive stents. Lumen area in the palladium-103 stents treatment group was larger than the control group. However, the reduction of neointima formation by palladium-103 stents implantation was in a non-dose-dependent fashion. Low ionizing radiation doses via γ-emitting palladiurn-103 stent are effective in preventing neointimal hyperplasia in iliac arteries of rabbits. Palladium-103 stents can be employed as a possible novel means to prevent in-stent restenosis.

  7. Drug-eluting stents in renal artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M. [Marienhospital Stuttgart, Department of Radiology, Stuttgart (Germany); Pattynama, P.M.T. [Erasmus MC-University Medical Center Rotterdam, Rotterdam (Netherlands); Talen, A. [genae associates nv, Antwerp (Belgium); Sapoval, M. [Hopital Europeen Georges Pompidou, Service de Radiologie Cardio-Vasculaire, Paris (France); Inserm U 780 epidemiologie Cardio Vasculaire, Paris (France)

    2008-04-15

    Because of higher acute and long-term success rates compared with balloon angioplasty alone, percutaneous stent implantation has become an accepted therapy for the treatment of atherosclerotic renal artery stenosis. Restenosis rates after successful renal stent placement vary from 6 up to 40%, depending on the definition of restenosis, the diameter of the treated vessel segment and comorbidities. The safety and efficacy of drug-eluting stents for the treatment of renal-artery stenosis is poorly defined. The recently published GREAT study is the only prospective study, comparing bare-metal and sirolimus-coated low profile stent systems in renal artery stenosis, showing a relative risk reduction of angiographic binary in-stent restenosis by 50%. This is an opinion paper on indications, current treatment options and restenosis rates following renal artery stenting and the potential use of drug-eluting stents for this indication. (orig.)

  8. Carotid artery stenting will replace carotid endarterectomy.

    Science.gov (United States)

    McCormick, Daniel J; Vlad, Tudor; Fasseas, Panayotis

    2007-09-01

    Stroke is the third leading cause of death in the United States. Carotid artery stenosis represents one of the most common etiologies of stroke. The current treatment modalities available for the treatment of carotid artery stenosis are carotid endarterectomy (CEA) and carotid artery stenting (CAS). Several clinical trials comparing CEA with medical management showed superiority of the surgical arm; however, the applicability of these results to the general population is limited by the fact that the patients and surgeons enrolled in these trials were carefully selected, and the optimal medical therapy used does not meet the current treatment standards. Carotid artery stenting has emerged as a treatment alternative to CEA, as shown in randomized trials comparing the 2 treatment modalities. Recent data from large-volume CAS registries indicate that percutaneous treatment of carotid artery stenosis compares favorably to CEA. Furthermore, the CAS trial designs make these results more applicable to the community standards. These data suggest that CAS will become the treatment of choice in patients with carotid artery stenosis.

  9. Carotid artery stenting: which stent for which lesion?

    Science.gov (United States)

    Bosiers, Marc; Deloose, Koen; Verbist, Jürgen; Peeters, Patrick

    2005-01-01

    The different geometries and working principles of carotid stents (nitinol or cobalt chromium, open- or closed-cell configuration) provide each product with unique functional properties. The individual characteristics of each device may make it an attractive choice in one circumstance but render it less desirable in other situations. In approximately 75% of all procedures, all types of stents will achieve similar outcomes, making adequate device selection unnecessary. For the remaining quarter, careful preoperative screening is mandatory. In addition to eventual access issues, the choice of the optimal carotid stent depends mainly on arterial anatomy and lesion morphology. When treating a tortuous anatomy, stents with a flexible and comformable open-cell configuration are preferred. In arteries with a significant mismatch between common carotid artery and internal carotid artery diameter, cobalt chromium (Elgiloy) or tapered nitinol stents are selected. Lesions with suspected high emboligenicity are best covered with stents with a closed-cell configuration, whereas highly calcified lesions need treatment with nitinol stents. Thorough knowledge of the characteristics, advantages and disadvantages, and working principles of the different available stents is mandatory to optimally select the materials to be used for patients eligible for carotid revascularization.

  10. Carotid Artery Stenting 2013: Thumbs up

    Science.gov (United States)

    Wagdi, Philipp

    2013-01-01

    It has been customary for interventional cardiologists involved in carotid artery stenting, to underline non-inferiority of the percutaneous technique versus surgical carotid endarterectomy. To that end, all cause morbidity and mortality figures of both methods are compared. Surgery has, in most large randomized studies, had an edge over stenting in terms of cerebrovascular adverse events. This may have partly been due to occasional indiscriminate indication for stenting in lesions and/or vessels with unfavourable characteristics (severe target vessel tortuosity and calcification, Type III aortic arch, and so on). On one hand, the author pleads for improvement of the excellent results of endarterectomy, by subjecting all patients planned for surgery to a thorough preoperative cardiological work up, including generous invasive investigation, thus reducing the incidence of perioperative myocardial infarction, heart failure and cardiac death. On the other hand, we are convinced that the results of carotid stenting should then be compared to best practice surgery. The rate of neurological adverse event rate after carotid endarterectomy at our institution lies under 0.7% at 30 days postoperatively. Specifically, the goal should be that carotid stenting underbids surgical endarterectomy, also and mainly, in terms of cerebral and cerebrovascular adverse events. Cardiac morbidity and mortality as well as laryngeal nerve palsy should no more be the main arguments for the percutaneous approach. This should easily be possible if patient selection for carotid revascularisation would be approached according to morphological criteria, in analogy with the “Syntax”-score used to optimise revascularisation strategies in coronary artery disease.

  11. Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schepis, Tiziano; Koepfli, Pascal; Gaemperli, Oliver; Eberli, Franz R.; Luescher, Thomas F. [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); Leschka, Sebastian; Desbiolles, Lotus; Husmann, Lars; Wildermuth, Simon; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); Zurich Center for Integrative Human Physiology, Zurich (Switzerland)

    2007-06-15

    We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 {+-} 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 {+-} 0.39 mm versus 2.49 {+-} 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 {+-} 6.2 mm, correlating well with CT (18.5 {+-} 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 {+-} 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA. (orig.)

  12. Estudo comparativo randomizado do implante de Stent de aço inoxidável recoberto por carbono semelhante ao diamante versus não recoberto em pacientes com doença arterial coronariana Randomized comparative study of diamond-like carbon coated stainless steel stent versus uncoated stent implantation in patients with coronary artery disease

    Directory of Open Access Journals (Sweden)

    George César Ximenes Meireles

    2007-04-01

    Full Text Available OBJETIVO: Comparar as taxas de reestenose e de eventos cardíacos maiores em um e seis meses pós-implante de stents recobertos com CSD com os não-recobertos. MÉTODOS: Estudo comparativo, prospectivo, randomizado, de 180 pacientes com diagnóstico de insuficiência coronária, submetidos a implante de stent recoberto com CSD (Phytis® ou stent não-recobertos (Penta®, no período de janeiro de 2003 a julho de 2004. Foram critérios de inclusão: lesão de novo com porcentual de estenose em diâmetro > 50% em artéria coronária com diâmetro de referência > 2,5 mm e OBJECTIVE: To compare restenosis and major cardiac event rates at one and six months after DLC-coated stent implantation with those of uncoated stents. METHODS: Randomized, prospective, comparative study of 180 patients with coronary insufficiency undergoing DLC coated stent (Phytis™ or uncoated stent (Penta™ implantation, from January, 2003 to July, 2004. Inclusion criteria were: de novo lesion with >50% diameter stenosis in a coronary artery with reference diameter > 2,5 mm and < 4 mm, and length < 20 mm. Exclusion criteria were: left main coronary artery and bifurcation lesions, chronic total occlusion, and in-stent restenosis. RESULTS: Clinical and angiographic baseline characteristics of the groups were similar. Procedural success was achieved in 98.9% of the patients in both groups. One cardiac death occurred in each group during hospitalization. Reference diameter and acute gain were greater in the Penta™ group (3.21±0.37 mm vs. 3.34±0.8 mm, p=0.02 and 2.3±0.5 vs. 2.49±0.5, p=0.009, respectively. Angiographic follow-up at six months showed similar rates of restenosis (24.3% vs. 21.8%, p=0.84 and of major cardiac events (16.8% vs. 17.5%, p=1. CONCLUSION: DLC coated stents did not provide better outcomes in relation to uncoated stents.

  13. Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design Considerations.

    Science.gov (United States)

    Beier, Susann; Ormiston, John; Webster, Mark; Cater, John; Norris, Stuart; Medrano-Gracia, Pau; Young, Alistair; Cowan, Brett

    2016-02-01

    Stent induced hemodynamic changes in the coronary arteries are associated with higher risk of adverse clinical outcome. The purpose of this study was to evaluate the impact of stent design on wall shear stress (WSS), time average WSS, and WSS gradient (WSSG), in idealized stent geometries using computational fluid dynamics. Strut spacing, thickness, luminal protrusion, and malapposition were systematically investigated and a comparison made between two commercially available stents (Omega and Biomatrix). Narrower strut spacing led to larger areas of adverse low WSS and high WSSG but these effects were mitigated when strut size was reduced, particularly for WSSG. Local hemodynamics worsened with luminal protrusion of the stent and with stent malapposition, adverse high WSS and WSSG were identified around peak flow and throughout the cardiac cycle respectively. For the Biomatrix stent, the adverse effect of thicker struts was mitigated by greater strut spacing, radial cell offset and flow-aligned struts. In conclusion, adverse hemodynamic effects of specific design features (such as strut size and narrow spacing) can be mitigated when combined with other hemodynamically beneficial design features but increased luminal protrusion can worsen the stent's hemodynamic profile significantly.

  14. Stent-induced coronary artery stenosis characterized by multimodal nonlinear optical microscopy

    Science.gov (United States)

    Wang, Han-Wei; Simianu, Vlad; Locker, Mattew J.; Cheng, Ji-Xin; Sturek, Michael

    2011-02-01

    We demonstrate for the first time the applicability of multimodal nonlinear optical (NLO) microscopy to the interrogation of stented coronary arteries under different diet and stent deployment conditions. Bare metal stents and Taxus drug-eluting stents (DES) were placed in coronary arteries of Ossabaw pigs of control and atherogenic diet groups. Multimodal NLO imaging was performed to inspect changes in arterial structures and compositions after stenting. Sum frequency generation, one of the multimodalities, was used for the quantitative analysis of collagen content in the peristent and in-stent artery segments of both pig groups. Atherogenic diet increased lipid and collagen in peristent segments. In-stent segments showed decreased collagen expression in neointima compared to media. Deployment of DES in atheromatous arteries inhibited collagen expression in the arterial media.

  15. Review of stents for the carotid artery.

    Science.gov (United States)

    Bosiers, M; Deloose, K; Verbist, J; Peeters, P

    2006-04-01

    The individual characteristics of a stent may make it an attractive choice in some circumstances, but render it a less desirable option in others. The applicability depends primarily on the arterial anatomy and the specific details of the lesion being treated. A careful assessment by the interventionalist is required to select the proper type of stent that is of appropriate size. Certainly, personal preferences and familiarity with a specific device may legitimately influence the decision to choose one stent over another. Finally, stent design can play a role in the selection procedure. Although carotid stents are often functionally equivalent in the clinical setting and have been used successfully to treat a wide variety of lesions, a basic knowledge of stent geometry can contribute to make up your mind in certain carotid cases.

  16. Stent treatment of symptomatic intracranial arterial stenosis

    Directory of Open Access Journals (Sweden)

    DONG Feng-ju

    2012-08-01

    Full Text Available Objective To investigate the safety, feasibility and efficacy of the Wingspan stent in treatment of symptomatic intracranial arterial stenosis. Methods Wingspan stenting was applied in 90 cases with symptomatic intracranial arterial stenosis. The surgical success rate and periprocedural neurological complications were observed. Digital subtraction angiography was performed at 6 months after stenting to detect the occurrence of restenosis. Results The technical success rate was 98.92% (92/93. Pre-treatment stenosis (83.42 ± 9.53% was improved to (21.82 ± 9.86% after stent placement. The difference was statistically significant (t = 3.280, P = 0.002. There were 5 patients (5.56% occurred major periprocedural neurological complications, 3 of them died within 30 days after the procedure. The restenosis rate at 6 months after operation was 19.10% (17/89. Conclusion Symptomatic intracranial arterial stenosis can be treated by Wingspan stenting with high technical success rate. The occurrence of complication is low and short-term efficacy is good. However, further study is needed to investigate long-term effect.

  17. Emerging Stent and Balloon Technologies in the Femoropopliteal Arteries

    Directory of Open Access Journals (Sweden)

    Georgios Pastromas

    2014-01-01

    Full Text Available Endovascular procedures for the management of the superficial femoral (SFA and popliteal artery disease are increasingly common. Over the past decade, several stent technologies have been established which may offer new options for improved clinical outcomes. This paper reviews the current evidence for SFA and popliteal artery angioplasty and stenting, with a focus on randomized trials and registries of nitinol self-expanding stents, drug-eluting stents, dug-coated balloons, and covered stent-grafts. We also highlight the limitations of the currently available data and the future routes in peripheral arterial disease (PAD stent and balloon technology.

  18. Carotid artery stenting : a 2009 update

    NARCIS (Netherlands)

    Zeebregts, Clark J.; Meerwaldt, Robbert; Geelkerken, Robert H.

    2009-01-01

    Purpose of review Carotid endarterectomy (CEA) is is still considered the gold standard in the treatment of patients with significant carotid stenosis and has proven its value over the past decades. Endovascular techniques have evolved, and carotid artery stenting (CAS) is challenging CEA to become

  19. A review on fracture prevention of stent in femoropopliteal artery

    Science.gov (United States)

    Atan, Bainun Akmal Mohd; Ismail, Al Emran; Taib, Ishkrizat; Lazim, Zulfaqih

    2017-01-01

    Heavily calcific lesions, total occlusions, tortuous blood vessels, variable lengths of arteries, various dynamic loads and deformations in the femoropopliteal (FP) arterial segment make stenosis treatments are complicated. The dynamic forces in FP artery including bending, torsion and radial compression may lead to stent fracture (SF) and eventually to in-stent restenosis (ISR). Stent design specifically geometrical configurations are a major factor need to be improved to optimize stent expansion and flexibility both bending and torsion during stent deployment into the diseased FP artery. Previous studies discovered the influence of various stent geometrical designs resulted different structural behaviour. Optimizing stent design can improve stent performances: flexibility and radial strength to prevent SF in FP arterial segment

  20. A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymer-based sirolimus-eluting stent compared to ENDEAVOR zotarolimus-eluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up results

    Institute of Scientific and Technical Information of China (English)

    XU Bo; LI Wei-min; CHEN Ji-yan; WANG Lei; WANG Yong; GE Jun-bo; LI Wei; GAO Run-lin; DOU Ke-fei; HAN Ya-ling; L(U) Shu-zheng; YANG Yue-jin; HUO Yong; WANG Le-feng; CHEN Yun-dai; WANG Hai-chang

    2011-01-01

    Background Available drug-eluting stents (DES) have achieved great success in reducing restenosis rates. Recently,investigators have demonstrated that the durable polymer carrier plays a significant role in DES-related hypersensitive reaction and delays vessel healing. TIVOLI stent is a novel sirolimus-eluting coronary stent with biodegradable coating containing sirolimus and polylactic-co-glycolic acid (PLGA) polymer. The present study sought to evaluate the effectiveness and safety of the TIVOLI biodegradable-polymer-based sirolimus-eluting stent in treating patients with coronary artery disease.Methods A prospective, multicenter clinical trial comparing TIVOLI biodegradable coated sirolimus-eluting stent with ENDEAVOR zotarolimus-eluting stent was conducted in 324 patients (TIVOLI group: 168 patients; ENDEAVOR group:156 patients) at 12 centers in China to demonstrate the non-inferiority of in-stent late loss with TIVOLI stent compared to ENDEAVOR stent in subjects with a maximum of two de novo native coronary artery lesions (lesion length ≤40 mm,reference vessel diameter 2.25-4.00 mm). The primary end point was angiographic in-stent late loss at 8-month. The secondary end points were clinical outcomes at 2 years,including major adverse cardiac events (cardiac death,myocardial infarction, or target-lesion revascularization) and stent thrombosis.Results Angiographic late lumen loss at 8 months in the TIVOLI group was superior to the ENDEAVOR group (in-stent (0.25±0.33) mm vs. (0.57±0.55) mm, diff (95% CI)-0.23 (-0.32, -0.14), P <0.0001; in-segment (0.25±-0.33) mm vs. (0.42±-0.55) mm, diff (95% CI) -0.13 (-0.23, -0.02),P=0.0083). The rate of in-stent binary restenosis at 8 months was reduced from 8.6% in the ENDEAVOR group to 2.9% in the TIVOLI group (P=0.0229). Compared to ENDEAVOR stent, TIVOLI stent resulted in a significant reduction in target-lesion revascularization (4.2% vs. 9.6%, P=0.0495) at 2 years. The two-year major adverse cardiac events (MACE

  1. Carotid artery stent continued expansion days after deployment, without post stent deployment angioplasty

    Directory of Open Access Journals (Sweden)

    Umair Qazi

    2015-10-01

    Full Text Available This is a carotid artery stent (CAS case report, which avoids post-stent deployment angioplasty (Post-SDA, with duplex confirmed continued stent expansion at 1, 3 and 30-day post deployment. This report confirms that self-expanding nitinol stents in the carotid artery may not require Post-SDA. We believe CAS can be performed without Post-SDA, which helps reduce the occurrence of intraoperative hemodynamic depression.

  2. Computational Analysis on Stent Geometries in Carotid Artery: A Review

    Science.gov (United States)

    Paisal, Muhammad Sufyan Amir; Taib, Ishkrizat; Ismail, Al Emran

    2017-01-01

    This paper reviews the work done by previous researchers in order to gather the information for the current study which about the computational analysis on stent geometry in carotid artery. The implantation of stent in carotid artery has become popular treatment for arterial diseases of hypertension such as stenosis, thrombosis, atherosclerosis and embolization, in reducing the rate of mortality and morbidity. For the stenting of an artery, the previous researchers did many type of mathematical models in which, the physiological variables of artery is analogized to electrical variables. Thus, the computational fluid dynamics (CFD) of artery could be done, which this method is also did by previous researchers. It lead to the current study in finding the hemodynamic characteristics due to artery stenting such as wall shear stress (WSS) and wall shear stress gradient (WSSG). Another objective of this study is to evaluate the nowadays stent configuration for full optimization in reducing the arterial side effect such as restenosis rate after a few weeks of stenting. The evaluation of stent is based on the decrease of strut-strut intersection, decrease of strut width and increase of the strut-strut spacing. The existing configuration of stents are actually good enough in widening the narrowed arterial wall but the disease such as thrombosis still occurs in early and late stage after the stent implantation. Thus, the outcome of this study is the prediction for the reduction of restenosis rate and the WSS distribution is predicted to be able in classifying which stent configuration is the best.

  3. Simulation of stent deployment in a realistic human coronary artery

    Directory of Open Access Journals (Sweden)

    van der Steen Anton FW

    2008-08-01

    Full Text Available Abstract Background The process of restenosis after a stenting procedure is related to local biomechanical environment. Arterial wall stresses caused by the interaction of the stent with the vascular wall and possibly stress induced stent strut fracture are two important parameters. The knowledge of these parameters after stent deployment in a patient derived 3D reconstruction of a diseased coronary artery might give insights in the understanding of the process of restenosis. Methods 3D reconstruction of a mildly stenosed coronary artery was carried out based on a combination of biplane angiography and intravascular ultrasound. Finite element method computations were performed to simulate the deployment of a stent inside the reconstructed coronary artery model at inflation pressure of 1.0 MPa. Strut thickness of the stent was varied to investigate stresses in the stent and the vessel wall. Results Deformed configurations, pressure-lumen area relationship and stress distribution in the arterial wall and stent struts were studied. The simulations show how the stent pushes the arterial wall towards the outside allowing the expansion of the occluded artery. Higher stresses in the arterial wall are present behind the stent struts and in regions where the arterial wall was thin. Values of 200 MPa for the peak stresses in the stent strut were detected near the connecting parts between the stent struts, and they were only just below the fatigue stress. Decreasing strut thickness might reduce arterial damage without increasing stresses in the struts significantly. Conclusion The method presented in this paper can be used to predict stresses in the stent struts and the vessel wall, and thus evaluate whether a specific stent design is optimal for a specific patient.

  4. Lesion load in unprotected carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Papanagiotou, P.; Roth, C.; Karp, K.; Krick, C.; Schieber, H.; Mueller, M.; Reith, W. [University of the Saarland, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Fassbender, K.; Haass, A. [University of the Saarland, Division of Neurology, Homburg (Germany)

    2009-05-15

    The purpose of the study was to determine the incidence of new ischemic lesions found on diffusion-weighted MR imaging (DWI) in nonselected patients after unprotected carotid artery stent placement. We retrospectively reviewed a nonrandomized cohort of 197 patients presenting with carotid occlusive disease who underwent unprotected carotid artery stent placement between 2003 and 2006. Mean degree of stenosis was 86.94% {+-} 9.72. In all patients, DWI was obtained before and 24 h after stent placement. New lesions were evaluated according to size and location. In 59 of 197 patients (29.9%), new ischemic lesions were found on DWI in the vessel dependent area. In 23 of 197 patients (11.7%), new ischemic lesions were found in the vessel independent area. Combined stroke/death rate was 3.63%. In our series of unprotected carotid angioplasty with stent, we found new DWI lesions in 34% of the patients. Further studies should now show in how far protection devices can reduce these lesions. (orig.)

  5. Mathematical model of carotid artery for stent placement

    Science.gov (United States)

    Rahman, Tengku Husna Tengku Abdul; Din, Ummul Khair Salma; Ahmad, Rokiah @ Rozita

    2016-11-01

    The carotid artery stenting is one of the methods used to reduce the effect of artherosclerosis which caused by the thickening of the artery wall. In most of the studies, the measure of wall elasticity, shear stress and the blood pressure through the blood flow were considered. The aim of this study is to determine the position to place the stent inside the carotid artery. A mathematical model is reconstructed to determine the suitable location of the stent in the carotid artery. Throughout the study, differences in fluid flow between a normal carotid artery wall and stenosed carotid artery wall are investigated. Since the existence of the stenosis provides a resistance in the flow, it is important to identify the right position to place the stent. The stent will be placed in the position where stenosis exists to ease the blood to flow normally. Later after the stent placement, the blood flow normally through the blood vessel.

  6. Nitinol Stent Fatigue in a Peripheral Human Artery Subjected to Pulsatile and Articulation Loading

    Science.gov (United States)

    Harvey, Sean Michael

    2011-07-01

    Nitinol self-expanding stents are used to treat peripheral occluded vessels such as the superficial femoral artery or the carotid. The complex vessel articulation requires a stent device that is flexible and kink resistant yet durable. The present study shows how the latest advances in commercially available engineering software tools permit engineering simulations of the many aspects of the Nitinol stent design and analysis. Two stent geometries are evaluated: a helical type stent design, and a more traditional straight strut, with multiple crowns design. The fatigue performance of the two stents is compared. The results show that advanced nonlinear finite element simulations and fatigue predictions of the Nitinol stent are possible today inside realistic simulated human arteries. The finite element analysis software used in this study is SimXpert, Marc, and Mentat (MSC Software, Santa Ana, CA).

  7. Reperfusion hemorrhage following superior mesenteric artery stenting.

    LENUS (Irish Health Repository)

    Moore, Michael

    2012-02-03

    Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

  8. Percutaneous transradial artery approach for coronary stent implantation.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J

    1993-10-01

    A new approach for implantation of Palmaz Schatz coronary stents is reported. We describe the technique and rationale of coronary stenting with miniaturized angioplasty equipment via the radial artery. This technique is illustrated in three patients. One patient underwent Palmaz Schatz stent implantation for a saphenous vene coronary bypass graft stenosis, the second patient for a restenosis in the anterior descending coronary artery after atherectomy, and the third patient for a second restenosis after balloon angioplasty in the circumflex coronary artery.

  9. Paraffin processing of stented arteries using a postfixation dissolution of metallic and polymeric stents.

    Science.gov (United States)

    Fishbein, Ilia; Welch, Tre; Guerrero, David T; Alferiev, Ivan S; Adamo, Richard F; Chorny, Michael; Gupte, Rohit K; Tang, Yanqing; Levy, Robert J

    Studying the morphology of the arterial response to endovascular stent implantation requires embedding the explanted stented artery in rigid materials such as poly(methyl methacrylate) to enable sectioning through both the in situ stent and the arterial wall, thus maintaining the proper anatomic relationships. This is a laborious, time-consuming process. Moreover, the technical quality of stained plastic sections is typically suboptimal and, in some cases, precludes immunohistochemical analysis. Here we describe a novel technique for dissolution of metallic and plastic stents that is compatible with subsequent embedding of "destented" arteries in paraffin, fine sectioning, major staining protocols, and immunohistochemistry.

  10. Microguidewire Looping to Traverse Stented Parent Arteries of Intracranial Aneurysms

    Science.gov (United States)

    Cho, Young Dae; Rhim, Jong Kook; Yoo, Dong Hyun; Kang, Hyun-Seung; Kim, Jeong Eun; Han, Moon Hee

    2017-01-01

    Objective Stents are widely used in coil embolization of intracranial aneurysms, but on occasion, a microcatheter must traverse a stented segment of artery (so-called trans-cell technique) to select an aneurysm, or double stenting may necessary. In such situations, microguidewire passage and microcatheter delivery through a tortuous stented parent artery may pose a technical challenge. Described herein is a microguidewire looping technique to facilitate endovascular navigation in these circumstances. Methods To apply this technique, the microguidewire tip is looped before entering the stented parent artery and then advanced distally past the stented segment, with the loop intact. Rounding of the tip prevents interference from stent struts during passage. A microcatheter is subsequently passed into the stented artery for positioning near the neck of aneurysm, with microguidewire assistance. The aneurysm is then selected, steering the microcatheter tip (via inner microguidewire) into the dome. Results This technique proved successful during coil embolization of nine saccular intracranial aneurysms (internal carotid artery [ICA], 6; middle cerebral artery, 2; basilar tip, 1), performing eight trans-cell deliveries and one additional stenting. Selective endovascular embolization was enabled in all patients, resulting in excellent clinical and radiologic outcomes, with no morbidity or mortality directly attributable to microguidewire looping. Conclusion Microguidewire looping is a reasonable alternative if passage through a stented artery is not feasible by traditional means, especially at paraclinoid ICA sites. PMID:28264249

  11. Effect of Shuxinyin (舒心饮) on In-Stent Restenosis after Coronary Artery Stenting

    Institute of Scientific and Technical Information of China (English)

    王显; 林钟香; 葛均波; 刘旭; 何燕; 张振贤; 沈琳

    2002-01-01

    Objective: To evaluate the effect of anti-platelet regimens and it's combination with Shuxinyin (SXY, 舒心饮,) on in-stent restenosis after stent implantation. Methods: Forty-four patients with successful stent implantation in a coronary artery were randomly assigned to the treated group (n=20) and the control group (n=24). The treated group received: SXY and anti-platelet therapy. The control group were treated with anti-platelet regimens only. Platelet activation was assessed before and immediately after the stenting by flow cytometry, the expression of P-selectin (CD62P) and glycoprotein(GP) Ⅱb/Ⅲa receptor. It was reassessed on the 30th day after stenting. Plasma fibrinogen (Fg) and C-reaction protein (CRP) were measured by biuret and laser scattering turbidimetry respectively at the same time. Observation was made on the scoring of the symptoms of Qi deficiency syndrome, Qi-Yin deficiency syndrome and blood stasis syndrome in the two groups. Differences between groups were compared. Results: Compared with the control group, combination with SXY and anti-platelet therapy was remarkable in reducing plasma CRP (P<0.05), and also with the tendency to decrease plasma Fg, GPⅡb/Ⅲa and CD62P. It could also evidently decrease the scoring of Qi-Yin deficiency syndrome, Qi deficiency syndrome and blood stasis syndrome after stenting (P<0.05, 0.01, 0.01) respectively. Follow-up survey found 40% relapse of angina pectoris with 4 cases of in-stent restenosis proved by angiography in the treated group. But the relapse of angina pectoris in the control group was 67% with 2 cases of myocardial infarction (MI), 7 cases of in-stent restenosis proved by angiography and one death. Conclusions: Combination with SXY and anti-platelet regimens can prevent stent thrombosis and in-stent restenosis after stent implantation, and it seems superior to anti-platelet therapy only.

  12. Simulation of stent deployment in a realistic human coronary artery

    NARCIS (Netherlands)

    F.J.H. Gijsen (Frank); F. Migliavacca (Francesco); S. Schievano (Silvia); L. Socci (Laura); L. Petrini (Lorenza); A. Thury (Attila); J.J. Wentzel (Jolanda); A.F.W. van der Steen (Ton); P.W.J.C. Serruys (Patrick); G. Dubini (Gabriele)

    2008-01-01

    textabstractBackground: The process of restenosis after a stenting procedure is related to local biomechanical environment. Arterial wall stresses caused by the interaction of the stent with the vascular wall and possibly stress induced stent strut fracture are two important parameters. The knowledg

  13. Delayed cerebral infarction due to stent folding deformation following carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kwon Duk; Lee, Kyung Yul; Suh, Sang Hyun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    We report a case of delayed cerebral infarction due to stent longitudinal folding deformation following carotid artery stenting using a self-expandable stent with an open-cell design. The stented segment of the left common carotid artery was divided into two different lumens by this folding deformation, and the separated lumens became restricted with in-stent thrombosis. Although no established method of managing this rare complication exists, a conservative approach was taken with administration of anticoagulant and dual antiplatelet therapy. No neurological symptoms were observed during several months of clinical follow-up after discharge.

  14. Application of 64 slice spiral CT in evaluating the patency of coronary artery after stent implantation

    Institute of Scientific and Technical Information of China (English)

    Yong-Shu Gao; Xing-Can Ma

    2015-01-01

    Objective:To explore the feasibility and effectiveness of 64 slice spiral CT in evaluating the patency of coronary artery after stent implantation.Methods:The 64 slice spiral CT image data of 125 patients after coronary artery stent implantation were collected, meanwhile, the image data of 25 patients underwent coronary angiography were also collected. The feasibility and accuracy of 64 slice spiral CT coronary artery stent imaging were comparatively analyzed. Results: The 64 slice spiral CT imaging quality with a stent diameter greater than 3.00 mm was significantly superior to that with a diameter of 2.25-3.00 mm. The CT imaging quality in the left main coronary artery and anterior descending artery was significantly higher than that in the left circumflex coronary artery. The CT imaging quality in the left main coronary artery was significantly higher than that in the right coronary artery. The CT reconstruction imaging quality in the drug coating stent was significantly superior to that in the bare metal stent. The sensitivity of 64 slice spiral CT was 100.00%, and the accuracy was 100.00%. In detecting the coronary artery with occlusion and stenosis (stent stenosis greater than 50%), the sensitivity was 90.00%, the false negative rate was 10.00%, and the positive predicative value was 100.00%.Conclusions:The effect of 64 slice spiral CT coronary imaging in evaluating the patency of coronary artery after stent implantation is highly consistent with that by coronary angiography, with a simple operation, less risk, and low cost, and thus, it can be completely taken as the imaging method in evaluating the patency of coronary artery after stent implantation.

  15. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  16. Endovascular rescue from arterial rupture and thrombosis during middle cerebral artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, J.Y.; Chung, Y.S. [Department of Neurosurgery, College of Medicine, Pundang CHA Hospital, 351 Yatap-ding, Pundang-gu, 463-712, Sungnam (Korea); Lee, B.H. [Department of Interventional Neuroradiology, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea); Kim, O.J. [Department of Emergency Medicine, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea)

    2003-08-01

    Intravascular stents are being used with increasing frequency in interventional neuroradiology. Iatrogenic arterial rupture is an uncommon but serious complication. We present a case of arterial rupture and subarachnoid haemorrhage during middle cerebral artery stenting, treated by emergency additional, overlapping stenting and balloon tamponade of the dissected vessel. Thrombotic occlusion of the artery was managed by intra-arterial abciximab. Normal vessel patency was re-established within 20 min and the patient recovered with no neurological deficit. (orig.)

  17. Drug-eluting versus bare-metal stents in large coronary arteries

    DEFF Research Database (Denmark)

    Kaiser, Christoph; Galatius, Soeren; Erne, Paul

    2010-01-01

    Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether...

  18. Influence of strut cross-section of stents on local hemodynamics in stented arteries

    Science.gov (United States)

    Jiang, Yongfei; Zhang, Jun; Zhao, Wanhua

    2016-05-01

    Stenting is a very effective treatment for stenotic vascular diseases, but vascular geometries altered by stent implantation may lead to flow disturbances which play an important role in the initiation and progression of restenosis, especially in the near wall in stented arterial regions. So stent designs have become one of the indispensable factors needed to be considered for reducing the flow disturbances. In this paper, the structural designs of strut cross-section are considered as an aspect of stent designs to be studied in details. Six virtual stents with different strut cross-section are designed for deployments in the same ideal arterial model. Computational fluid dynamics (CFD) methods are performed to study how the shape and the aspect ratio (AR) of strut cross-section modified the local hemodynamics in the stented segments. The results indicate that stents with different strut cross-sections have different influence on the hemodynamics. Stents with streamlined cross-sectional struts for circular arc or elliptical arc can significantly enhance wall shear stress (WSS) in the stented segments, and reduce the flow disturbances around stent struts. The performances of stents with streamlined cross-sectional struts are better than that of stents with non-streamlined cross-sectional struts for rectangle. The results also show that stents with a larger AR cross-section are more conductive to improve the blood flow. The present study provides an understanding of the flow physics in the vicinity of stent struts and indicates that the shape and AR of strut cross-section ought to be considered as important factors to minimize flow disturbance in stent designs.

  19. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Matthias C. Burg

    2011-01-01

    Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  20. Plaque components affect wall stress in stented human carotid artery:A numerical study

    Institute of Scientific and Technical Information of China (English)

    Zhen-Min Fan; Xiao Liu; Cheng-Fei Du; An-Qiang Sun; Nan Zhang; Zhan-Ming Fan; Yu-Bo Fan; Xiao-Yan Deng

    2016-01-01

    Carotid artery stenting presents challenges of in-stent restenosis and late thrombosis, which are caused primarily by alterations in the mechanical environment of the artery after stent implantation. The present study con-structed patient-specific carotid arterial bifurcation models with lipid pools and calcified components based on magnetic resonance imaging. We numerically analyzed the effects of multicomponent plaques on the distributions of von Mises stresses (VMSs) in the patient-specific models after stenting. The results showed that when a stent was deployed, the large soft lipid pool in atherosclerotic plaques cushioned the host artery and reduced the stress within the arterial wall;how-ever, this resulted in a sharp increase of VMS in the fibrous cap. When compared with the lipid pool, the presence of the calcified components led to slightly increased stresses on the luminal surface. However, when a calcification was located close to the luminal surface of the host artery and the stenosis, the local VMS was elevated. Overall, compared with calcified components, large lipid pools severely dam-aged the host artery after stenting. Furthermore, damage due to the calcified component may depend on location.

  1. Plaque components affect wall stress in stented human carotid artery: A numerical study

    Science.gov (United States)

    Fan, Zhen-Min; Liu, Xiao; Du, Cheng-Fei; Sun, An-Qiang; Zhang, Nan; Fan, Zhan-Ming; Fan, Yu-Bo; Deng, Xiao-Yan

    2016-09-01

    Carotid artery stenting presents challenges of in-stent restenosis and late thrombosis, which are caused primarily by alterations in the mechanical environment of the artery after stent implantation. The present study constructed patient-specific carotid arterial bifurcation models with lipid pools and calcified components based on magnetic resonance imaging. We numerically analyzed the effects of multicomponent plaques on the distributions of von Mises stresses (VMSs) in the patient-specific models after stenting. The results showed that when a stent was deployed, the large soft lipid pool in atherosclerotic plaques cushioned the host artery and reduced the stress within the arterial wall; however, this resulted in a sharp increase of VMS in the fibrous cap. When compared with the lipid pool, the presence of the calcified components led to slightly increased stresses on the luminal surface. However, when a calcification was located close to the luminal surface of the host artery and the stenosis, the local VMS was elevated. Overall, compared with calcified components, large lipid pools severely damaged the host artery after stenting. Furthermore, damage due to the calcified component may depend on location.

  2. Computational Modelling of Multi-folded Balloon Delivery Systems for Coronary Artery Stenting: Insights into Patient-Specific Stent Malapposition.

    Science.gov (United States)

    Ragkousis, Georgios E; Curzen, Nick; Bressloff, Neil W

    2015-08-01

    Despite the clinical effectiveness of coronary artery stenting, percutaneous coronary intervention or "stenting" is not free of complications. Stent malapposition (SM) is a common feature of "stenting" particularly in challenging anatomy, such as that characterized by long, tortuous and bifurcated segments. SM is an important risk factor for stent thrombosis and recently it has been associated with longitudinal stent deformation. SM is the result of many factors including reference diameter, vessel tapering, the deployment pressure and the eccentric anatomy of the vessel. For the purpose of the present paper, virtual multi-folded balloon models have been developed for simulated deployment in both constant and varying diameter vessels under uniform pressure. The virtual balloons have been compared to available compliance charts to ensure realistic inflation response at nominal pressures. Thereafter, patient-specific simulations of stenting have been conducted aiming to reduce SM. Different scalar indicators, which allow a more global quantitative judgement of the mechanical performance of each delivery system, have been implemented. The results indicate that at constant pressure, the proposed balloon models can increase the minimum stent lumen area and thereby significantly decrease SM.

  3. Irradiation and dosimetry of Nitinol stent for renal artery brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Arbabi, Azim [Science and Research Campus, Islamic Azad University, P.O. Box 14515-775, Tehran (Iran, Islamic Republic of); Shahid Beheshti Medical University, P.O. Box 14335-1419, Tehran (Iran, Islamic Republic of); Sadeghi, Mahdi [Science and Research Campus, Islamic Azad University, P.O. Box 14515-775, Tehran (Iran, Islamic Republic of); Nuclear Medicine Research Group, Agricultural, Medical and Industrial Research School, P.O. Box 31485-498, Karaj (Iran, Islamic Republic of)], E-mail: msadeghi@nrcam.org; Joharifard, Mahdi [Science and Research Campus, Islamic Azad University, P.O. Box 14515-775, Tehran (Iran, Islamic Republic of)

    2009-01-15

    This study was conducted to assess the suitability of {sup 48}V radioactive stent for use in renal artery brachytherapy. A nickel-titanium alloy Nitinol stent was irradiated over the proton energy range of up to 8.5 MeV, to obtain {sup 48}V. The depth dose distribution analysis of the activated stent was done with TLD-700GR in a Perspex phantom. We investigated a unique mixed gamma/beta brachytherapy source of {sup 48}V. For a 10 mm outer-diameter {sup 48}V stent, the average measured dose rate to vessel was 37 mGy/h. The dosimetry results of the {sup 48}V stent suggest that the stent is suitable for use in renal artery brachytherapy.

  4. Off-pump coronary artery bypass grafting or percutaneous transluminal coronary angioplasty with stenting for proximal left anterior descending coronary artery disease?

    NARCIS (Netherlands)

    Drenth, Derk Jan

    2005-01-01

    This thesis describes and discusses the results of a prospective randomized controlled clinical trial comparing percutaneous coronary angioplasty with stenting (stenting) and off-pump coronary artery bypass grafting with a left internal mammary artery (surgery) in patients with a high-grade stenosis

  5. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group.

    OpenAIRE

    Serruys, P.W.; de Jaegere, P; Kiemeneij, F.; Macaya, C; Rutsch, W; Heyndrickx, G.; Emanuelsson, H.; Marco, J.; Legrand, Victor; Materne, P.

    1994-01-01

    BACKGROUND: Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as compared with standard balloon angioplasty. METHODS: A total of 520 patients with stable angina and a single coronary-artery lesion were randomly assigned to either stent implantation (262 patients)...

  6. Cognitive changes after carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Politi, M.; Struffert, T.; Krick, C.; Backens, M. [University of the Saarland, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Supprian, T.; Falkai, P.; Reith, W. [University of the Saarland, Clinic for Psychiatry and Psychotherapy, Homburg (Germany)

    2006-05-15

    We aimed to test changes in cognitive performance after carotid artery stenting (CAS). Ten patients were neuropsychologically tested at least 24 h before and 48 h after CAS. To diminish thromboembolic events, we used a proximal protection device. The following neuropsychological tests were selected: The Mini Mental State Examination (MMSE), symbol digit test and subtests of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) battery (verbal fluency, constructional practice, word list memory and delayed recall). Affective state was determined by the Beck Depression Score (BDS). No patient suffered from depression (BDS <1) or dementia (MMSE 29.9{+-}1.5). Nine of the ten patients (P=0.12) showed increased speed in the Number Connection Test (NCT) (corresponding to trail making test). Most patients showed better or similar results concerning delayed recall (P=0.31). No change was observed in the symbol digit test, word list memory, verbal fluency or constructional practice. Better results concerning NCT and delayed recall after carotid stenting might be due to improved brain perfusion. After CAS, cognitive and memory performance seem to improve. Further studies with different time intervals and more refined testing, as well as perfusion-weighted imaging, are needed. (orig.)

  7. Frequency and consequences of early in-stent lesions after carotid artery stent placement.

    NARCIS (Netherlands)

    Jongen, L.M.; Hendrikse, J.; Waaijer, A.; Worp, H.B. van der; Leijdekkers, V.J.; Lo, R.T.; Mali, W.P.Th.; Prokop, M.

    2009-01-01

    PURPOSE: To examine the prevalence of in-stent lesions 1 month after carotid artery stent placement with multidetector computed tomography (CT) angiography and to evaluate their possible causes and their consequences during 1-year follow-up. MATERIALS AND METHODS: Sixty-nine patients with symptomati

  8. Technical options for treatment of in-stent restenosis after carotid artery stenting

    NARCIS (Netherlands)

    Pourier, Vanessa E C; de Borst, Gert J.

    2016-01-01

    Objective This review summarizes the available evidence and analyzes the current trends on treatments for carotid in-stent restenosis (ISR) after carotid artery stenting (CAS). Methods An update of a 2010 review of the literature (which included 20 articles) was conducted using PubMed and Embase. Al

  9. Safety and efficacy of coronary drug eluting stent for atherosclerotic stenosis of the small renal artery

    Institute of Scientific and Technical Information of China (English)

    LI Chun-jie; WU Zheng; YAN Hong-bing; WANG Jian; ZHAO Han-jun

    2009-01-01

    @@ Small diameter renal artery refers to the renal artery with the cross-section diameter less than 5 mm, the incidence of which is approximately 8%.1 Small diameter renal artery is common in patients with congenital multi-branch renal arteries, diabetes and multi-coronary artery lesions. Renal artery bare-mental stent (BMS) implantation is the standard treatment for ostial renal artery stenosis.2,3 However, the restenosis rate4-6 is too high and becomes one of the relative contraindications for small diameter renal artery stent implantation. Clinical trials (e.g. RAVEL,7,8 SIRIUS9 and TAXUS-IV10) have proved that drug eluting stent (DES), compared with BMS, can reduce the restenosis rate after the percutanous coronary intervention (PCI). And Huda et al11 claimed that DES had the better results than BMS in the treatment of obstructive superficial femoral artery disease. However,there are few studies involved restenosis after the renal artery intervention. We hypothesized that coronary DES applied in renal artery stenosis might inhibit intimal proliferation effectively as in coronary artery disease;therefore we evaluated the results of 25 patients with atherosclerotic renal artery stenosis treated using coronary DES to assess the safety and efficacy of coronary DES in patients with small renal artery stenotic lesions.

  10. Renal subcapsular haematoma: an unusual complication of renal artery stenting

    Institute of Scientific and Technical Information of China (English)

    XIA Dan; CHEN Shan-wen; ZHANG Hong-kun; WANG Shuo

    2011-01-01

    After successful renal artery angioplasty and stent placement, a patient in a fully anticoagulated state developed hypotension and flank pain. Computed tomography (CT) of the abdomen revealed a large renal subcapsular haematoma which was successfully managed conservatively without embolotherapy and surgical intervention. To prevent hemorrhage after renal artery stenting, it is necessary to underscore the importance of reducing the contrast volume and pressure of angiography, controlling systemic blood pressure, and monitoring guide wire position at all times.

  11. Primary stenting as emergency therapy in acute basilar artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Spreer, Joachim; Arnold, Sebastian; Klisch, Joachim; Schumacher, Martin [Section of Neuroradiology, University Hospital Freiburg, Breisacher Strasse 64, 79106 Freiburg (Germany); Els, Thomas; Hetzel, Andreas; Huppertz, Hans-Juergen; Oehm, Eckhardt [Department of Neurology, University Hospital Freiburg, Freiburg (Germany)

    2002-09-01

    In three patients with acute occlusion of the basilar artery intra-arterial fibrinolysis resulted in only partial recanalization and revealed severe stenosis as the underlying cause. Application of micro-stents without previous dilatation resulted in vessel re-opening. Two patients had an excellent clinical outcome. One patient died 10 days after the stroke due to brainstem infarction. Emergency primary stent application may improve the outcome in acute basilar artery occlusion, if intra-arterial thrombolysis fails to re-establish a sufficient flow. (orig.)

  12. Drug diffusion and biological responses of arteries using a drug-eluting stent with nonuniform coating

    Directory of Open Access Journals (Sweden)

    Saito N

    2016-03-01

    Full Text Available Noboru Saito, Yuhei Mori, Sayaka Uchiyama Terumo Corporation R&D Center, Inokuchi, Nakai-machi, Ashigarakami-gun, Kanagawa, Japan Abstract: The purpose of this study was to determine the effect of a nonuniform coating, abluminal-gradient coating (AGC, which leaves the abluminal surface of the curves and links parts of the stent free from the drug coating, on the diffusion direction of the drug and the biological responses of the artery to drug-eluting stent (DES by comparing the AGC-sirolimus stent and the conventional full-surface coating (CFC sirolimus stent. The study aimed to verify whether the AGC approach was appropriate for the development of a safer DES, minimizing the risks of stent thrombosis due to delayed endothelialization by the drug and distal embolization due to cracking of the coating layer on the hinge parts of the DES on stent expansion. In the in vitro local drug diffusion study, we used rhodamine B as a model drug, and rhodamine B released from the AGC stent diffused predominantly into the abluminal side of the alginate artery model. Conversely, rhodamine B released from the CFC stent quickly spread to the luminal side of the artery model, where endothelial cell regeneration is required. In the biological responses study, the luminal surface of the iliac artery implanted with the AGC-sirolimus stent in a rabbit iliac artery for 2 weeks was completely covered with endothelial-like cells. On the other hand, the luminal surface of the iliac artery implanted with the CFC-sirolimus stent for 2 weeks only showed partial coverage with endothelial-like cells. While thrombosis was observed in two of the three CFC-sirolimus stents, it was observed in only one of the three AGC-sirolimus stents. Taken together, these findings indicate that the designed nonuniform coating (AGC is an appropriate approach to ensure a safer DES. However, the number of studies is limited and a larger study should be conducted to reach a statistically

  13. Clinicians' contributions to the development of coronary artery stents: a qualitative study of transformative device innovation.

    Directory of Open Access Journals (Sweden)

    Aaron S Kesselheim

    Full Text Available BACKGROUND: Medical device innovation remains poorly understood, and policymakers disagree over how to incentivize early development. We sought to elucidate the components of transformative health care innovation by conducting an in-depth case study of development of a key medical device: coronary artery stents. METHODS AND FINDINGS: We conducted semi-structured interviews with the innovators whose work contributed to the development of coronary artery stents who we identified based on a review of the regulatory, patent, and medical literature. Semi-structured interviews with each participant covered the interviewee's personal involvement in coronary artery stent development, the roles of institutions and other individuals in the development process, the interplay of funding and intellectual property in the interviewee's contribution, and finally reflections on lessons arising from the experience. Transcripts were analyzed using standard coding techniques and the constant comparative method of qualitative data analysis. CONCLUSIONS: We found that the first coronary artery stents emerged from three teams: Julio Palmaz and Richard Schatz, Cesare Gianturco and Gary Roubin, and Ulrich Sigwart. First, these individual physician-inventors saw the need for coronary artery stents in their clinical practice. In response, they developed prototypes with the support of academic medical centers leading to early validation studies. Larger companies entered afterwards with engineering support. Patents became paramount once the technology diffused. The case of coronary stents suggests that innovation policy should focus on supporting early physician-inventors at academic centers.

  14. The Development of Coronary Artery Stents: From Bare-Metal to Bio-Resorbable Types

    Directory of Open Access Journals (Sweden)

    Ming-Yun Ho

    2016-07-01

    Full Text Available Coronary artery disease is the leading cause of death worldwide. Conventional balloon angioplasty is associated with high rates of complications such as coronary dissection and vessel recoil. The deployment of bare-metal stents (BMSs can overcome these problems and achieve a better patency rate than simple balloon angioplasty. It has been shown that the stent design including structure platform, size, length, and strut thickness has a major influence on the clinical results. Even though angioplasty with BMS implantation is widely used in coronary interventions, the restenosis rate due to neointimal hyperplasia remains high. Therefore, drug-eluting stents (DESs coated with anti-proliferative agents and polymers have been developed to reduce the restenosis rate and improve the clinical outcomes. Although the repeat revascularization rate of DESs is lower than that of BMSs, the long-term stent thrombosis rate is higher than for BMSs. Therefore, new and emerging generations of stents, in which, for example, thinner struts and bioresorbable polymers are used, are available for clinical use. However, there are only a limited number of clinical trials, in which these newer stents have been compared with BMSs and first- and second-generation DESs. The purpose of this review was to provide up-to-date information on the evolution of coronary artery stents from BMSs to DESs to bioresorbable stents (BRSs.

  15. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R. [Univ. of Muenster (Germany). Dept. of Clinical Radiology; Grude, M. [Univ. of Muenster (Germany). Dept. of Cardiology and Angiology

    2003-11-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 {+-} 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  16. Minimally invasive coronary artery bypass grafting versus stenting for patients with proximal left anterior descending coronary artery disease.

    Science.gov (United States)

    Shirai, Kazuyuki; Lansky, Alexandra J; Mehran, Roxana; Dangas, George D; Costantini, Costantino O; Fahy, Martin; Slack, Steven; Mintz, Gary S; Stone, Gregg W; Leon, Martin B

    2004-04-15

    The purpose of this study was to compare the clinical outcomes of stenting and minimally invasive coronary artery bypass grafting (MIDCAB) in patients with proximal left anterior descending (LAD) coronary artery disease. The Patency, Outcome, Economics of Minimally invasive direct coronary bypass (POEM) study demonstrated that MIDCAB had similar safety and long-term efficacy for LAD revascularization compared with conventional coronary artery bypass grafting. Although LAD stenting is superior to conventional balloon angioplasty, whether it is comparable to MIDCAB is not known. We identified a matched population of 429 consecutive patients with 1-vessel disease who underwent elective proximal LAD stenting and compared their clinical outcomes with those of the 152 patients in the MIDCAB group of the POEM study. The in-hospital event rate was similar in both groups, except for a shorter length of hospital stay with LAD stenting compared with MIDCAB (2.68 vs 4.07 days, p <0.0001). At 6-month follow-up, the incidence of death and Q-wave myocardial infarction or that of cerebrovascular accident was not significantly different between these 2 groups. However, target vessel revascularization was significantly higher with LAD stenting than MIDCAB (13.3% vs 6.6%, p = 0.045). In the subgroup of patients without diabetes, all clinical events were similar in both groups, and the benefit of a shorter hospital stay associated with stenting was maintained. Compared with MIDCAB, LAD stenting is associated with higher repeat revascularization rates but offers the advantage of shorter hospitalization. For nondiabetics with proximal LAD disease, stenting may be the revascularization strategy of choice.

  17. Radial forces of stents used in thoracic endovascular aortic repair and bare self-expanding nitinol stents measured ex vivo - Rapid rescue for obstruction of the innominate artery using bare self-expanding nitinol stents.

    Science.gov (United States)

    Matsumoto, Takuya; Inoue, Kentaro; Tanaka, Shinichi; Aoyagi, Yukihiko; Matsubara, Yutaka; Matsuda, Daisuke; Yoshiya, Keiji; Yoshiga, Ryosuke; Ohkusa, Tomoko; Maehara, Yoshihiko

    2017-02-01

    Purpose Our objective was to compare the radial forces of several stents ex vivo to identify stents suitable for rescue of the unexpected coverage of aortic arch branches in thoracic endovascular aortic repair. Methods We measured the radial forces of two types of self-expanding bare nitinol stents (E-luminexx and Epic) used singly or as double-walled pairs, and of three endoprostheses used in thoracic endovascular aortic repair (TEVAR, Gore c-TAG, Relay, and Valiant) by compressing the stent using an MTS Instron universal testing machine (model #5582). We also examined the compressive effects of the TEVAR endoprostheses and the bare nitinol stents on each other. Results The radial force was greater in the center than at the edge of each stent. In all stents tested, the radial force decreased incrementally with increasing stent diameter. The radial force at the center was two times greater when using two stents than with a single stent. In the compression test, only E-luminexx used as a pair was not compressed after compressing a Relay endoprosthesis by 12 mm. Conclusion Two E-luminexx stents are appropriate to restore the blood flow if a TEVAR endoprosthesis covers the innominate artery following innominate-carotid-left subclavian arterial bypass.

  18. Comparison of short-term outcomes after carotid artery stenting according to different stent designs

    Science.gov (United States)

    Açar, Göksel; Özkan, Birol; Alıcı, Gökhan; Yazıcıoglu, Mehmet Vefik; Bulut, Mustafa; Kalkan, Mehmet Emin; Demir, Serdar; Acar, Rezzan Deniz; Boztosun, Bilal

    2013-01-01

    Introduction In the developed countries, stroke is the third most common cause of death. There are many data indicating that stents reduce the risk of embolism but there are few publications assessing whether different stent designs can influence the periprocedural complications. Aim To determine the effects of open- and closed-cell stent designs on 1-month results of carotid artery stenting (CAS). Material and methods The study group consisted of 290 consecutive patients (216 men and 74 women, mean age 66.6 ±8.7 years). Neuroprotection with a distal protection device was used in all cases. The patients were divided into two groups: the open-cell stent group (n = 144) and the closed-cell stent group (n = 138). Major adverse cardiac and cerebrovascular events (MACCE) described as myocardial infarction, stroke and death within 1 month were recorded and analysed subsequently. Periprocedural hypotension and transient cerebral ischaemia at 1 month after the CAS procedure were also assessed. Results We treated 290 carotid stenoses and stents were implanted in all patients. Fifteen patients (5.5%) were treated by staged CAS due to bilateral carotid artery disease. The technical success rate was 97.2%. There was no difference in the MACCE and transient cerebral ischaemia rate at 1 month between the two groups (p = 0.44 and p = 0.94, respectively). The incidence of ischaemic stroke was lower in the closed-cell stent group (2.77% vs. 0%; p = 0.04). The periprocedural rate of hypotension was higher in the closed-cell stent group (2.1% vs. 7.2%; p = 0.04). Conclusions Closed-cell stents are associated with a low rate of ischaemic stroke. We think that closed-cell stents may be preferred in patients at high risk of embolism. PMID:24570703

  19. Local Angiopeptin Delivery Using Coated Stents Reduces Neointimal Proliferation in Overstretched Porcine Coronary Arteries.

    Science.gov (United States)

    De Scheerder I; Wilczek; Van Dorpe J; Verbeken; Cathapermal; Wang; Desmet; Schacht; Foegh; De Geest H; Piessens

    1996-06-01

    BACKGROUND: Systemic administration of angiopeptin has been shown to inhibit myointimal thickening after arterial injury in several animal species. METHODS AND RESULTS: To explore to what extent high and long-lasting local concentrations of angiopeptin influence the healing process after vascular injury, tantalum balloon-expandable stents were first coated with a polymer loaded with angiopeptin 250 µg. Implantation of these stents in porcine coronary arteries resulted in tissue concentrations of 10.7 pg/ml wet weight in the stented arterial segment 24 hours after stent implantation, gradually declining to 2.0 pg/ml wet weight at day 8. Finally, 20 pigs were randomly treated with either an angiopeptin-loaded or a blank-coated stent. At baseline, the angiographic parameters were similar between both groups but, after 6 weeks, the minimal luminal diameter of the stented arterial segment was larger in the angiopeptin-treated pigs when compared to controls (2.20 +/- 0.57 mm vs 1.57 +/- 0.68 mm, p < 0.01) This angiographic finding was confirmed by post-mortem morphometry where the respective lumen area values were 1.00 +/- 0.54 mm2 and 0.43 +/- 0.28 mm2 (p < 0.01). CONCLUSION: Polymer coated stents can be loaded with angiopeptin, which after implantation in porcine right coronary arteries result in high local tissue concentrations gradually declining over more than 8 days. These high local concentrations inhibit myointimal proliferation induced by poly(organo)phosphazene coated overstretched stents.

  20. High-definition computed tomography for coronary artery stents imaging: Initial evaluation of the optimal reconstruction algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Xiaoming, E-mail: mmayzy2008@126.com; Li, Tao, E-mail: litaofeivip@163.com; Li, Xin, E-mail: lx0803@sina.com.cn; Zhou, Weihua, E-mail: wangxue0606@gmail.com

    2015-05-15

    Highlights: • High-resolution scan mode is appropriate for imaging coronary stent. • HD-detail reconstruction algorithm is stent-dedicated kernel. • The intrastent lumen visibility also depends on stent diameter and material. - Abstract: Objective: The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Materials and methods: Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. Results: The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0 ± 8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Conclusions: Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement.

  1. [Exrercise tolerance in patients with coronary artery disease after coronary artery stenting].

    Science.gov (United States)

    Tseluyko, V; Kreyndel, K; Vashakidze, Z

    2014-01-01

    The aim of the research is to investigate the impact of coronary stenting on exercise tolerance after 4-8 week and after 12-15 months. The study involved total 90 patients with coronary artery disease, who underwent coronary stenting. All patients underwent clinical examination, including an assessment of their condition, the frequency of angina attacks, echocardioscopy, resting ECG was recorded in all the patients in the standard 12 -lead veloergometry. Statistical processing was performed using Statistica 6.0 for Windows, the method of Wald - Wolfowitz . Data are presented as arithmetic means and error average M ± m. We used a statistical method of calculation - the median ranks (with the median calculated by the usual rules of statistics - the arithmetic mean of the central members of the ordered series). Significant differences were assessed by t-test . The level of significance was considered significant when p <0,05. According to the monitoring data of patients have a significant increase in exercise tolerance: threshold power increased by 63% and in 12-15 months by 58 % compared with the original. The duration of the test conducted after stenting increased by almost 2 -fold. In addition, significantly reduced the proportion of patients whose test results were evaluated as positive. Stenting of the coronary arteries after 4-8 weeks promotes the significant increase in exercise tolerance that persists after 12-15 months. The factors of associated with insufficient increase in exercise tolerance after stenting according veloergometry are: female gender, diabetes, smoking cessation further contributes to the increase in the threshold of physical activity.

  2. Stent-based mechanical thrombectomy in acute basilar artery occlusion.

    Science.gov (United States)

    Cohen, José E; Leker, Ronen R; Moscovici, Samuel; Attia, Moshe; Itshayek, Eyal

    2011-12-01

    Stent-based mechanical thrombectomy was recently proposed as an effective alternative to other mechanical techniques to achieve recanalization of large-vessel embolic occlusions in the anterior circulation. To our knowledge, there are no reports of the use of this technique in acute basilar artery occlusion (ABAO). We present a patient with complete endovascular recanalization of ABAO using a stent-based thrombectomy technique. Advantages and limitations of this technique in the management of ABAO are discussed. The stent-thrombectomy technique is promising, and will need further evaluation in posterior circulation stroke.

  3. Shortening of Wallstent RP during carotid artery stenting requires appropriate stent placement.

    Science.gov (United States)

    Aikawa, Hiroshi; Nagata, Shun-ichi; Onizuka, Masanari; Tsutsumi, Masanori; Iko, Minoru; Kodama, Tomonobu; Nii, Kouhei; Matsubara, Shuko; Etou, Hosei; Go, Yoshinori; Kazekawa, Kiyoshi

    2008-06-01

    Changes in the location and length of the Wallstent RP during carotid artery stenting (CAS) were evaluated using intraoperative videos of 28 patients with carotid artery stenosis who underwent CAS with a 10/20 mm Wallstent RP to determine the appropriate stent placement. The stent was deployed after its midpoint was positioned over a virtual center line, the perpendicular line which crossed the most stenotic point of the lesion on the road mapping image. The length of the stenotic lesion, the changes in the locations of the distal and proximal ends of the stent, and the changes in stent length were examined. The distal end of the stent moved a maximum of 6.1 mm toward the proximal side to a point 19.9 mm from the virtual center line. The proximal end moved a maximum of 11.3 mm toward the distal side to a point 14.7 mm from the virtual center line. The stent length ranged from 37.7 to 44.5 mm (mean 41.2 mm). The 10/20 mm Wallstent RP placed by our technique covers the entire lesion with no less than 5.7 mm of margin over the segment distal to the lesion in patients with stenotic segments shorter than 29.4 mm.

  4. Biodegradable polymeric stents for vascular application in a porcine carotid artery model: English version.

    Science.gov (United States)

    Kischkel, S; Grabow, N; Püschel, A; Erdle, B; Kabelitz, M; Martin, D P; Williams, S F; Bombor, I; Sternberg, K; Schmitz, K-P; Schareck, W; Bünger, C M

    Over the past years the development of biodegradable polymeric stents has made great progress; nevertheless, essential problems must still be solved. Modifications in design and chemical composition should optimize the quality of biodegradable stents and remove the weaknesses. New biodegradable poly-L-lactide/poly-4-hydroxybutyrate (PLLA/P4HB) stents and permanent 316L stents were implantedendovascularly into both common carotid arteries of 10 domestic pigs. At 4 weeks following implantation, computed tomography (CT) angiography was carried out to identify the distal degree of stenosis. The PLLA/P4HB group showed a considerably lower distal degree of stenosis by additional oral application of atorvastatin (mean 39.81 ± 8.57 %) compared to the untreated PLLA/P4HB group without atorvastatin (mean 52.05 ± 5.80 %). The 316L stents showed no differences in the degree of distal stenosis between the group treated with atorvastatin (mean 44.21 ± 2.34 %) and the untreated group (mean 35.65 ± 3.72 %). Biodegradable PLLA/P4HB stents generally represent a promising approach to resolving the existing problems in the use of permanent stents. Restitutio ad integrum is only achievable if a stent is completely degraded.

  5. Placement of Endovascular Stent across the Branching Arteries: Long-term Serial Evaluation of Stent-tissue Responses Overlying the Arterial Orifices in an Experimental Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Il; Chung, Jin Wook, E-mail: chungjw@snu.ac.kr [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of); Kim, Hyun Beom [National Cancer Center of Korea, Department of Radiology and Center for Liver Cancer, Research Institute and Hospital (Korea, Republic of); Park, Jae Hyung [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of); Seo, Jeong Wook [Seoul National University College of Medicine, Department of Pathology (Korea, Republic of); Kim, Hyo-Cheol; Jae, Hwan Jun; Lee, Whal [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of)

    2012-10-15

    PurposeThis study was designed to investigate the effects of stenting across the branching arteries on the patency and stent-tissue responses over the branching arterial orifices. Methods: Thirteen dogs were observed after placing aortic stents across the celiac arteries (CA), superior mesenteric arteries (SMA), and renal arteries (RA). The animals were grouped according to stent types: large-cell group (n = 6) and small-cell group (n = 7). Angiography was performed to evaluate the branching artery patency at 2, 6, and 12 months after stent insertion, and the stent-tissue responses covering the orifices were evaluated on histopathologic examination. Results: All branching arteries were patent on follow-up angiography; however, three patterns of stent-tissue responses over the orifices were observed: neointimal layering, bridging septa, and papillary hyperplasia. Although neointimal layering and bridging septa were evenly observed, severe papillary hyperplasia was more frequent at SMA and CA than RA. Four RA showed less than 50% ostial patency, and localized infarct was observed in six kidneys (24%). The ostial patency tended to decrease with small-cell stent during the follow-up period. Conclusions: Various stent-tissue responses over the branching artery orifices are induced by the aortic stent covering the branching arteries and may not be easily detected by conventional angiography. Subclinical renal infarct also may occur despite patent renal angiography.

  6. PTA and stent placement distal to the superficial femoral artery; PTA und Stent distal der AFS

    Energy Technology Data Exchange (ETDEWEB)

    Rand, T.; Stadler, A.; Schoder, M.; Kettenbach, J. [Medizinische Universitaet Wien, Klinische Abteilung fuer Angiographie und Interventionelle Radiologie, Wien (Austria); Haumer, M. [Klinik fuer Innere Medizin II des Universitaetsklinikums Wien, Klinische Abteilung fuer Angiologie, Wien (Austria)

    2006-11-15

    Although angioplasty and stent applications in the iliac vessels and the superficial femoral artery have become routine procedures, their usefulness for the treatment of lesions of the popliteal artery and the lower leg arteries is still under discussion. For the popliteal artery, limitations are mainly due to the high mechanical stress in this area, causing high traction forces. Moreover, beyond the occlusive atherosclerotic changes, specific pathological entities such as aneurysms, emboli, entrapment syndromes, and cystic adventitial disease have to be differentiated. There is hope that the development of innovative stent designs with high flexibility might overcome the limitations. For lesions of the lower leg arteries treatment with percutaneous transluminal angioplasty (PTA) has become the method of choice. However, stent designs as used for cardiac interventions have been adapted for their application below the knee, and first encouraging results may help to justify their broad use in the future. Regarding PTA, innovative equipment and techniques for the treatment of arterial lesions below the knee include dedicated, long, and very flexible balloons, cutting balloon cryoplasty, and laser angioplasty. Regarding stents, bare metal stents, stents with passive or active coatings, and bioabsorbable stents have all been successfully used. (orig.) [German] Waehrend Angioplastie (PTA) und Stentbehandlung im Bereich der Beckengefaesse sich zu etablierten interventionellen Standardverfahren entwickelt haben, ist die endovaskulaere Behandlung von Laesionen der A. poplitea und auch der Unterschenkelgefaesse noch in Diskussion. Gruende hierfuer sind bei der A. poplitea v. a. die unguenstigen mechanischen Faktoren, die hohe Traktionskraefte am Gefaess wirken lassen und besonders die Gefaesspathologien, die neben der stenosierenden Atherosklerose auch andere spezifische Auspraegungen wie Aneurysmen, Embolien, Entrapmentsyndrome und die zystische Adventitianekrose umfassen

  7. Sirolimus-eluting stent fractures associated with aneurysm and very late stent thrombosis in the right coronary artery

    Institute of Scientific and Technical Information of China (English)

    LIU Xuebo; Gary S.Mintz; Stéphane G.Carlier; Martin B.Leon

    2007-01-01

      Although the occurrence of coronary stent fracture is rare,recent reports showed that stent fracture after sirolimus-eluting stent(SES)implantation may be associated with neointimal hyperplasia and restenosis.We report two cases of stent fracture that occurred late after elective SES implantation into the right coronary artery(RCA)that were related to the aneurysm,restenosis,thrombosis,and vessel occlusion.……

  8. Modification of the No-Touch Technique during Renal Artery Stenting

    Directory of Open Access Journals (Sweden)

    John A. Stathopoulos

    2013-01-01

    Full Text Available Renal artery stenting has been established as the primary form of renal artery stenosis revascularization procedure. The no-touch technique is proposed in order to avoid renal artery injury and atheroembolism during renal artery stenting. We describe a modification of the no-touch technique by using an over-the-wire (OTW balloon or a Quickcross catheter with a coronary wire inside, instead of the rigid  J wire. The reported technique, while it prevents direct contact of the guiding catheter with the aortic wall, at the same time it allows for a closer contact with the renal arterial ostium and a more favorable guiding catheter orientation, compared to what is achieved with the use of the more rigid  J wire, thus improving visualization, reducing the amount of contrast required, and potentially decreasing complications.

  9. Treatment of carotid artery aneurysms with covered stents; Aneurysmabehandlung der Arteria carotis interna mit gecoverten Stents

    Energy Technology Data Exchange (ETDEWEB)

    Rohr, A.; Alfke, K.; Doerner, L.; Jansen, O. [UKSH Kiel (Germany). Neurochirurgie Neuroradiologie; Bartsch, T.; Stingele, R. [UKSH Kiel (Germany). Neurologie

    2007-10-15

    Purpose: Evaluation of the use of covered stents in treating pseudoaneurysms of the cervical and intracranial/extradural carotid artery and determination of the periprocedural and short- to mid-term complication rate. Materials and Methods: 8 patients with 9 spontaneous dissecting aneurysms of the cervical carotid artery - 5 of which were symptomatic - plus one patient with ofthalmoplegia due to an aneurysm of the cavernous carotid artery were studied. While the latter was treated with a PTFE-covered balloon-mounted stainless steel stent (Jostent/Graftmaster), a self-expanding PTFE-covered Nitonol Stent (Symbiot) was used in all other cases. Intervention was performed with local anesthesia. Aspirin and Clopidogrel were both used as antiplatelet drugs. Clinical signs and symptoms and vascular imaging with DS, MR, CT angiography and ultrasound were recorded during patient follow-up, with a mean follow-up period of 14.6 months (4 - 30). Results: We were able to treat 8 out of 10 aneurysms (80 %) using covered stents. The aneurysms were immediately occluded and the associated stenoses of the parent vessel were eliminated. No clinically relevant complications occurred during the procedure or in the follow-up interval. In two cases, elongation of the carotid artery prevented the stent from being positioned over the aneurysm neck. These cases were shown to be stable with the use of antiplatelet drugs. Conclusion: Covered stents can be used in the treatment of pseudoaneurysms of the carotid artery as an alternative to long-term antithrombotic medication or surgery. In our study treatment was effective (80 %) and free of complications in the short- and mid-term follow-up. Possible indications, technique and the use of imaging modalities for patient follow-up are discussed. (orig.)

  10. Successful treatment of coronary artery pseudoaneurysm by graft stent, which developed after the implantation of bare metal stent

    Directory of Open Access Journals (Sweden)

    Utku Şenol

    2013-03-01

    Full Text Available Although coronary artery pseudoaneurysm which couldoccur following percutaneous coronary interventions is arare complication, it can be mortal. As soon as the pseudoaneurysmis diagnosed, it should be treated by percutaneousintervention or surgery. Graft stent implantationis a preferred treatment for appropriate patients. In thiscase report, we presented a successful treatment of coronaryartery pseudoaneurysm by graft stent; which developedafter the implantation of bare metal stent into theleft anterior descending coronary artery. J Clin Exp Invest2013; 4 (1: 126-129Key words: Coronary artery, pseudoaneurysm, graft stent

  11. On the necessity of modelling fluid-structure interaction for stented coronary arteries.

    Science.gov (United States)

    Chiastra, Claudio; Migliavacca, Francesco; Martínez, Miguel Ángel; Malvè, Mauro

    2014-06-01

    Although stenting is the most commonly performed procedure for the treatment of coronary atherosclerotic lesions, in-stent restenosis (ISR) remains one of the most serious clinical complications. An important stimulus to ISR is the altered hemodynamics with abnormal shear stresses on endothelial cells generated by the stent presence. Computational fluid dynamics is a valid tool for studying the local hemodynamics of stented vessels, allowing the calculation of the wall shear stress (WSS), which is otherwise not directly possible to be measured in vivo. However, in these numerical simulations the arterial wall and the stent are considered rigid and fixed, an assumption that may influence the WSS and flow patterns. Therefore, the aim of this work is to perform fluid-structure interaction (FSI) analyses of a stented coronary artery in order to understand the effects of the wall compliance on the hemodynamic quantities. Two different materials are considered for the stent: cobalt-chromium (CoCr) and poly-l-lactide (PLLA). The results of the FSI and the corresponding rigid-wall models are compared, focusing in particular on the analysis of the WSS distribution. Results showed similar trends in terms of instantaneous and time-averaged WSS between compliant and rigid-wall cases. In particular, the difference of percentage area exposed to TAWSS lower than 0.4Pa between the CoCr FSI and the rigid-wall cases was about 1.5% while between the PLLA cases 1.0%. The results indicate that, for idealized models of a stented coronary artery, the rigid-wall assumption for fluid dynamic simulations appears adequate when the aim of the study is the analysis of near-wall quantities like WSS.

  12. Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Maintz, David; Juergens, Kai-Uwe; Heindel, Walter; Fischbach, Roman [Department of Clinical Radiology, University of Muenster, Albert-Schweitzer-Strasse 33, 48129 Muenster (Germany); Wichter, Thomas; Grude, Matthias [Department of Cardiology and Angiology, University of Muenster, Albert-Schweitzer-Strasse 33 48129 Muenster (Germany)

    2003-04-01

    The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally obscured in the Wiktor stent, the Wallgraft stent, and the Nir Royal stent. Partial residual of the stent lumen could be visualized in all other utilized stent products (artificial lumen reductions ranged from 62% in the V-Flex stent to 94% in the Bx Velocity stent). Parts of the stent lumen can be visualized in most coronary artery stents; however, detectability of in-stent stenoses remains to be evaluated for each stent type. (orig.)

  13. Endarterectomy or carotid artery stenting : the quest continues part two

    NARCIS (Netherlands)

    Kolkert, Joe L.; Meerwaldt, Robbert; Geelkerken, Robert H.; Zeebregts, Clark J.

    2015-01-01

    BACKGROUND: Although randomized trials on carotid artery stenting (CAS) could not establish its equivalence to carotid endarterectomy (CEA) in patients with symptomatic carotid disease, CAS is rapidly evolving. Data on long-term outcome after CAS from randomized trials have now become available and

  14. Quality of life after PCI with drug-eluting stents or coronary-artery bypass surgery

    NARCIS (Netherlands)

    D.J. Cohen (David J.); B.A. van Hout (Ben); P.W.J.C. Serruys (Patrick); F.W. Mohr (Friedrich); C.M. Miguel (Carlos); P. den Heijer (Peter); M.M. Vrakking (M. M.); K.K. Wang (Kenneth); E.M. Mahoney (Elizabeth M.); S. Audi (Salma); K. Leadly (Katrin); K.D. Dawkins (Keith); A.P. Kappetein (Arie Pieter)

    2011-01-01

    textabstractBACKGROUND: Previous studies have shown that among patients undergoing multivessel revascularization, coronary-artery bypass grafting (CABG), as compared with percutaneous coronary intervention (PCI) either by means of balloon angioplasty or with the use of bare-metal stents, results in

  15. RADAR – A randomised, multi-centre, prospective study comparing best medical treatment versus best medical treatment plus renal artery stenting in patients with haemodynamically relevant atherosclerotic renal artery stenosis

    Directory of Open Access Journals (Sweden)

    Hauk Michael

    2009-07-01

    Full Text Available Abstract Background Prospective, international, multi-centre, randomised (1:1 trial to evaluate the clinical impact of percutaneous transluminal renal artery stenting (PTRAS on the impaired renal function measured by the estimated glomerular filtration rate (eGFR in patients with haemodynamically significant atherosclerotic renal artery stenosis. Methods Patients will be randomised to receive either PTRAS using the Dynamic Renal Stent system plus best medical treatment or best medical treatment. Renal stenting will be performed under angiographic imaging. For patients randomised to best medical treatment the degree of stenosis measured by renal duplex sonography (RDS will be confirmed by MR angio or multi-slice CT where possible. Best medical treatment will be initiated at randomisation or post procedure (for PTRAS arm only, and adjusted as needed at all visits. Best medical treatment is defined as optimal drug therapy for control of the major risk factors (blood pressure ≤ 125/80 mmHg, LDL cholesterol ≤ 100 mg/dL, HbA1c ≤ 6.5%. Data recordings include serum creatinine values, eGFR, brain natriuretic peptide, patients' medical history and concomitant medication, clinical events, quality of life questionnaire (SF-12v2™, 24 hour ambulatory blood pressure measurement, renal artery duplex ultrasound and echocardiography. Follow-up intervals are at 2, 6, 12 and 36 months following randomisation. The primary endpoint is the difference between treatments in change of eGFR over 12 months. Major secondary endpoints are technical success, change of renal function based on the eGFR slope change between pre-treatment and post-treatment (i.e. improvement, stabilisation, failure, clinical events overall such as renal or cardiac death, stroke, myocardial infarction, hospitalisation for congestive heart failure, progressive renal insufficiency (i.e. need for dialysis, need of target vessel revascularisation or target lesion revascularisation, change in

  16. Carotid artery stenting: Rationale, technique, and current concepts

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Hasan, E-mail: hasan.yilmaz@hcuge.c [Department of Interventional and Diagnostic Neuroradiology, University Hospital of Geneva (Switzerland); Pereira, Vitor Mendes; Narata, Ana-Paula [Department of Interventional and Diagnostic Neuroradiology, University Hospital of Geneva (Switzerland); Sztajzel, Roman [Department of Neurology, University Hospital of Geneva (Switzerland); Lovblad, Karl-Olof [Department of Interventional and Diagnostic Neuroradiology, University Hospital of Geneva (Switzerland)

    2010-07-15

    Carotid stenosis is a major risk factor for stroke. With the aging of the general population and the availability of non-invasive vascular imaging studies, the diagnosis of a carotid plaque is commonly made in medical practice. Asymptomatic and symptomatic carotid stenoses need to be considered separately because their natural history is different. Two large randomized controlled trials (RCTs) showed the effectiveness of carotid endarterectomy (CEA) in preventing ipsilateral ischemic events in patients with symptomatic severe stenosis. The benefit of surgery is much less for moderate stenosis and harmful in patients with stenosis less than 50%. Surgery has a marginal benefit in patients with asymptomatic stenosis. Improvements in medical treatment must be taken into consideration when interpreting the results of these previous trials which compared surgery against medical treatment available at the time the trials were conducted. Carotid artery stenting (CAS) might avoid the risks associated with surgery, including cranial nerve palsy, myocardial infarction, or pulmonary embolism. Therefore and additionally to well-established indications of CAS, this endovascular approach might be a valid alternative particularly in patients at high surgical risk. However, trials of endovascular treatment of carotid stenosis have failed to provide enough evidence to justify routine CAS as an alternative to CEA in patients suitable for surgery. More data from ongoing randomized trials of CEA versus CAS will be soon available. These results will help determining the role of CAS in the management of patients with carotid artery stenosis.

  17. Mechanical compression of coronary artery stents: potential hazard for patients undergoing cardiopulmonary resuscitation.

    Science.gov (United States)

    Windecker, S; Maier, W; Eberli, F R; Meier, B; Hess, O M

    2000-12-01

    Mechanical compression of coronary artery stents may be associated with a fatal outcome as the result of refractory myocardial ischemia. We present the history of an 83-yr-old patient, who died owing to hemorrhagic shock 3 days after stent implantation, despite immediate cardiopulmonary resuscitation (CPR). Postmortem examination showed stent compression, probably due to mechanical deformation during CPR. This complication has been reported in two other cases in the literature, suggesting that CPR may be hazardous to patients with coronary artery stents.

  18. Angioplasty and stent treatment of transplant renal artery stenosis.

    Science.gov (United States)

    Del Pozo, Maitane; Martí, Jordi; Guirado, Lluís; Facundo, Carme; Canal, Cristina; de la Torre, Pablo; Ballarín, José; Díaz, Joan M

    2012-07-17

    Transplant renal artery stenosis is a major complication that requires a therapeutic approach involving surgery or angioplasty. The aim of this study was to analyse the evolution of renal transplant patients with renal allograft artery stenosis treated by angioplasty and stent placement. Thirteen patients were diagnosed with transplant renal artery stenosis. Clinical suspicion was based on deterioration of renal function and/or poorly controlled hypertension with compatible Doppler ultrasound findings. The diagnosis was confirmed by arteriography, performing an angioplasty with stent placement during the same operation. A progressive improvement in renal function was observed during the first 3 months after the angioplasty, and renal function then remained stable over 2 years. In addition, blood pressure improved during the first 2 years, and as a consequence there was no need to increase the average number of anti-hypertensive drugs administered (2.5 drugs per patient). In conclusion, angioplasty with stent placement is a safe and effective procedure for the treatment of transplant renal artery stenosis.

  19. Magnesium alloy covered stent for treatment of a lateral aneurysm model in rabbit common carotid artery: An in vivo study

    Science.gov (United States)

    Wang, Wu; Wang, Yong-Li; Chen, Mo; Chen, Liang; Zhang, Jian; Li, Yong-Dong; Li, Ming-Hua; Yuan, Guang-Yin

    2016-11-01

    Magnesium alloy covered stents have rarely been used in the common carotid artery (CCA). We evaluated the long-term efficacy of magnesium alloy covered stents in a lateral aneurysm model in rabbit CCA. Magnesium alloy covered stents (group A, n = 7) or Willis covered stents (group B, n = 5) were inserted in 12 New Zealand White rabbits and they were followed up for 12 months. The long-term feasibility for aneurysm occlusion was studied through angiograms; the changes in vessel area and lumen area were assessed with IVUS. Complete aneurysmal occlusion was achieved in all aneurysms. Angiography showed that the diameter of the stented CCA in group A at 6 and 12 months was significantly greater than the diameter immediately after stent placement. On intravascular ultrasound (IVUS) examination, the mean lumen area of the stented CCA in group A was significantly greater at 6 and 12 months than that immediately after stent placement; the mean lumen area was also significantly greater in group A than in group B at the same time points. The magnesium alloy covered stents proved to be an effective approach for occlusion of lateral aneurysm in the rabbit CCA; it provides distinct advantages that are comparable to that obtained with the Willis covered stent.

  20. Safety, efficacy and costs associated with direct coronary stenting compared with stenting after predilatation

    Science.gov (United States)

    IJsselmuiden, A.; Serruys, P.W.; Tangelder, G.J.; Slagboom, T.; van der Wieken, R.; Kiemeneij, F.; Laarman, G.J.

    2004-01-01

    Objectives Comparison of the in-hospital success rates, procedural costs and short-term clinical outcomes of direct stenting versus stenting after balloon predilatation. Methods Altogether, 400 patients with angina pectoris and/or myocardial ischaemia due to coronary stenoses in a single native vessel were randomised to either direct stenting or stenting after predilatation. Baseline characteristics were evenly distributed between the two groups. Results Procedural success rates were similar (96.0% direct stenting group vs. 94.5% predilatation) as well as final successful stent implantation (98.3 vs. 97.8%), while the primary success rate of direct stenting alone was 88.3%, p=0.01. In multivariate analysis, angiographic lesion calcification was an independent predictor of unsuccessful direct stenting (odds ratio 7.1, 95% confidence interval 2.8-18.2, p0.15 μg/l, used as a measure of distal embolisation, were similar in both groups (17.8 vs. 17.1%). Rates of major adverse cardiac events at 30 days were 4.5% in the direct stenting group versus 5.5% in the predilated group (ns). Direct stenting was associated with savings in fluoroscopy time, and angiographic contrast agent use, and a reduction in utilisation of angioplasty balloons (0.4 vs. 1.17 balloons per patient, p<0.001). Mean per patient procedural costs associated with direct stenting versus predilatation were €2545±914 versus €2763±842 (p=0.01), despite the implantation of more stents in the directly stented group. Conclusion Compared with a strategy of stenting preceded by balloon predilatation, direct stenting was equally safe and effective, with similar in-hospital and 30-day clinical outcomes, and modest procedural cost-savings. A calcified lesion predicted unsuccessful direct stenting. PMID:25696356

  1. Computer Simulation of the Mechanical Behaviour of Implanted Biodegradable Stents in a Remodelling Artery

    Science.gov (United States)

    Boland, Enda L.; Grogan, James A.; Conway, Claire; McHugh, Peter E.

    2016-04-01

    Coronary stents have revolutionised the treatment of coronary artery disease. While coronary artery stenting is now relatively mature, significant scientific and technological challenges still remain. One of the most fertile technological growth areas is biodegradable stents; here, there is the possibility to generate stents that will break down in the body once the initial necessary scaffolding period is past (6-12 months) (Grogan et al. in Acta Biomater 7:3523, 2011) and when the artery has remodelled (including the formation of neo-intima). A stent angioplasty computational test-bed has been developed by the authors, based on the Abaqus software (DS-SIMULIA, USA), capable of simulating stent tracking, balloon expansion, recoil and in vivo loading in a atherosclerotic artery model. Additionally, a surface corrosion model to simulate uniform and pitting corrosion of biodegradable stents and a representation of the active response of the arterial tissue following stent implantation, i.e. neointimal remodelling, has been developed. The arterial neointimal remodelling simulations with biodegradable stent corrosion demonstrate that the development of new arterial tissue around the stent struts has a substantial effect on the mechanical behaviour of degrading stents.

  2. Hepatic artery pseudoaneurysm treated using stent-graft implantation and retrograde gastroduodenal artery coil embolization

    Energy Technology Data Exchange (ETDEWEB)

    Basile, Antonio; Patti, Maria Teresa [Ospedale Ferrarotto, Department of Diagnostic and Interventional Radiology, Catania (Italy); Ragazzi, Salvatore; Piazza, Diego [Ospedale Vittorio Emanuele, Department of Surgery I, Catania (Italy); Tsetis, Dimitrios [University Hospital of Heraklion, Medical School of Crete, Department of Radiology, Heraklion (Greece); Lupattelli, Tommaso [Multimedica Holding, Department of Interventional Radiology, Sesto S. Giovanni (Italy)

    2008-11-15

    Endovascular treatment options for visceral artery pseudoaneurysms depend on lesion location and size. Exclusion methods fall into two categories, embolization and stent placement, and these procedures aim to exclude the pseudoaneurysm from the circulation and if possible to maintain distal blood flow. Embolization of the afferent artery can be used in pseudoaneurysms that arise from a donor artery without collateral supply such as a visceral branch, whereas in the case of visceral arteries with well-established collateral supply, the embolization of both proximal and distal branches to the pseudoaneurysm is mandatory in preventing backflow from the collateral circulation. A direct embolization delivering coils or glue into the sac can also be performed if the aneurismal neck is narrow. Stent-graft placement represents another option to exclude the pseudoaneurysm, in the case of wide neck, reduced arterial tortuosity and large-diameter arteries. We present a case of common hepatic artery pseudoaneurysm involving the gastroduodenal artery origin treated by a combination of techniques. An hepatic stent-graft implantation plus retrograde embolization of the gastroduodenal artery through the pancreaticoduodenal anastomosis from the superior mesenteric artery was performed. (orig.)

  3. The role of carotid artery stenting for recent cerebral ischemia.

    Science.gov (United States)

    Bosiers, M; Callaert, J; Deloose, K; Verbist, J; Keirse, K; Peeters, P

    2010-06-01

    Patients with cerebral ischemia as a result of acute cervical internal carotid artery occlusion are generally considered to have a poor prognosis. Despite maximal medical treatment, a better treatment for patients with acute ischemic stroke who present with serious neurologic symptoms on admission or continue to deteriorate neurologically due to a total occlusion, a dissection or a high-grade stenosis of the internal carotid artery is required. An effective intervention to improve their neurologic symptoms and clinical outcome has not yet been established and represents a challenging and complex problem. Treatment of acute symptomatic occlusion of the cervical internal carotid artery includes intravenous administration of thrombolytic agent, carotid endarterectomy and an interventional approach (intra-arterial administration of thrombolytic agent, transluminal angioplasty with or without stenting). The endovascular interventional approach is becoming a part of the stroke therapy armamentarium for intracranial occlusion. It may also now be considered in select patients with acute internal carotid artery occlusion. Stenting and angioplasty for acute internal carotid artery occlusion appears to be feasible, safe and may be associated with early neurological improvement. The encouraging preliminary results await confirmation from prospective, randomized studies.

  4. Low-profile stent system for treatment of atherosclerotic renal artery stenosis: The GREAT trial

    NARCIS (Netherlands)

    Sapoval, M.; Zahringer, M.; Pattynama, P.; Rabbia, C.; Vignali, C.; Maleux, G.; Boyer, L.; Szczerbo-Trojanowska, M.; Jaschke, W.; Hafsahl, G.; Downes, M.; Beregi, J.P.; Veeger, N.; Talen, A.

    2005-01-01

    PURPOSE: The Palmaz Genesis Peripheral Stainless Steel Balloon Expandable Stent in Renal Artery Treatment (GREAT) Trial was designed to assess the safety and performance of a low-profile stent for the treatment of obstructive renal artery disease by looking at 6-month renal artery patency uniformly

  5. Low-profile stent system for treatment of atherosclerotic renal artery stenosis : The GREAT trial

    NARCIS (Netherlands)

    Sapoval, M; Zahringer, M; Pattynama, P; Rabbia, C; Vignali, C; Maleux, G; Boyer, L; Szczerbo-Trojanowska, M; Jaschke, W; Hafsahl, G; Downes, M; Beregi, JP; Veeger, N; Talen, A

    2005-01-01

    PURPOSE: The Palmaz Genesis Peripheral Stainless Steel Balloon Expandable Stent in Renal Artery Treatment (GREAT) Trial was designed to assess the safety and performance of a low-profile stent for the treatment of obstructive renal artery disease by looking at 6-month renal artery patency uniformly

  6. New stent design for use in small coronary arteries during percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Juan F Granada

    2010-10-01

    Full Text Available Juan F Granada1, Barbara A Huibregtse2, Keith D Dawkins21The Jack H Skirball Center for Cardiovascular Research, Cardiovascular Research Foundation, Columbia University Medical Center, New York, NY, USA; 2Boston Scientific Corporation, Natick, MA, USAAbstract: Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel, and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches, intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001, instent binary restenosis (13.0% versus 38.1%, P < 0.001, and target lesion revascularization (5.8% versus 17.6%, P < 0.001 at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03 and instent binary restenosis (13.0% versus 25.9%, P = 0.02 when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS

  7. Treatment of splenic artery aneurysm with double overlapping bare stents: case report

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Hyo Sung; Han, Young Min; Jin, Gong Yong [School of Medicine, Chonbuk National Univ., Chonju (Korea, Republic of)

    2004-09-01

    The traditional treatment of splenic artery aneurysm (SAA) is generally surgery and/or transcatheter arterial embolization, but recently, the treatment of SAA using a stent graft has been reported. However, the acute angle of the celiac axis, as well as the tortuous path of the splenic artery makes the use of stent graft difficult for treatment of aneurysma. We report here a case of SAA treated with the technique of double overlapping metallic stents.

  8. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, Nicholas, E-mail: nicholas.chalmers@cmft.nhs.uk [Manchester Royal Infirmary, Department of Radiology (United Kingdom); Walker, Paul T. [James Cook University Hospital, Department of Radiology (United Kingdom); Belli, Anna-Maria [St. George' s Healthcare NHS Trust, Department of Radiology (United Kingdom); Thorpe, Anthony P. [Aberdeen Royal Infirmary, Department of Radiology (United Kingdom); Sidhu, Paul S. [King' s College Hospital, Department of Radiology (United Kingdom); Robinson, Graham [Hull Royal Infirmary, Department of Radiology (United Kingdom); Ransbeeck, Mariella van [Johnson and Johnson Medical NV/SA, Cordis (Belgium); Fearn, Steven A. [Johnson and Johnson Medical Ltd., Cordis (United Kingdom)

    2013-04-15

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5-22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months' follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  9. Inflammation and in-stent restenosis: the role of serum markers and stent characteristics in carotid artery stenting.

    Directory of Open Access Journals (Sweden)

    Katrin Wasser

    Full Text Available BACKGROUND: Carotid angioplasty and stenting (CAS may currently be recommended especially in younger patients with a high-grade carotid artery stenosis. However, evidence is accumulating that in-stent restenosis (ISR could be an important factor endangering the long-term efficacy of CAS. The aim of this study was to investigate the influence of inflammatory serum markers and procedure-related factors on ISR as diagnosed with duplex sonography. METHODS: We analyzed 210 CAS procedures in 194 patients which were done at a single university hospital between May 2003 and June 2010. Periprocedural C-reactive protein (CRP and leukocyte count as well as stent design and geometry, and other periprocedural factors were analyzed with respect to the occurrence of an ISR as diagnosed with serial carotid duplex ultrasound investigations during clinical long-term follow-up. RESULTS: Over a median of 33.4 months follow-up (IQR: 14.9-53.7 of 210 procedures (mean age of 67.9±9.7 years, 71.9% male, 71.0% symptomatic an ISR of ≥70% was detected in 5.7% after a median of 8.6 months (IQR: 3.4-17.3. After multiple regression analysis, leukocyte count after CAS-intervention (odds ratio (OR: 1.31, 95% confidence interval (CI: 1.02-1.69; p = 0.036, as well as stent length and width were associated with the development of an ISR during follow-up (OR: 1.25, 95% CI: 1.05-1.65, p = 0.022 and OR: 0.28, 95% CI: 0.09-0.84, p = 0.010. CONCLUSIONS: The majority of ISR during long-term follow-up after CAS occur within the first year. ISR is associated with periinterventional inflammation markers and influenced by certain stent characteristics such as stent length and width. Our findings support the assumption that stent geometry leading to vessel injury as well as periprocedural inflammation during CAS plays a pivotal role in the development of carotid artery ISR.

  10. Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Saguner, Ardan M., E-mail: ardan.saguner@usz.ch; Traupe, Tobias; Raeber, Lorenz; Hess, Nina [University Hospital, Swiss Cardiovascular Center (Switzerland); Banz, Yara [University of Bern, Institute of Pathology (Switzerland); Saguner, Arhan R.; Diehm, Nicolas; Hess, Otto M. [University Hospital, Swiss Cardiovascular Center (Switzerland)

    2012-08-15

    Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5-6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into 'normal-sized' (stent-to-artery-ratio < 1.4, n = 12) and 'oversized' (stent-to-artery-ratio {>=} 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

  11. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong Suk, E-mail: hongsukpark@gmail.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Do, Young Soo, E-mail: ysdo@skku.edu [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Kim, Duk-Kyung, E-mail: dukkyung.kim@samsung.com [Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, Sung Wook, E-mail: sw.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Shin, Sung Wook, E-mail: sw88.shin@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Cho, Sung Ki, E-mail: sungkismc@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Hyun, Dongho, E-mail: mesentery.hyun@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, In Wook, E-mail: inwook.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of)

    2013-11-01

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure.

  12. Percutaneous radial intervention for complex bilateral renal artery stenosis using paclitaxel eluting stents.

    Science.gov (United States)

    Granillo, Gastón A Rodriguez; van Dijk, Lukas C; McFadden, Eugène P; Serruys, Patrick W

    2005-01-01

    Techniques used in the coronary circulation may be useful in peripheral intervention. We report a case of bilateral renal artery stenosis treated via a radial approach by direct stenting with distal protection at a right ostial lesion and modified crush stenting at a left renal bifurcation lesion using paclitaxel-eluting stents.

  13. The 10-year Trend of Periprocedural Complication Following Carotid Artery Stenting; Single Center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jeong-Ho [Keimyung University Dongsan Medical Center, Department of Neurology (Korea, Republic of); Kang, Jihoon; Yeo, Min-Ju; Kim, Beom Joon; Jang, Min Uk; Bae, Hee-Joon [Seoul National University College of Medicine, Department of Neurology, Stroke Center, Seoul National University Bundang Hospital (Korea, Republic of); Kwon, O-Ki; Hwang, Gyo Jun; Oh, Chang Wan [Seoul National University Bundang Hospital, Department of Neurosurgery (Korea, Republic of); Jung, Cheolkyu [Seoul National University Bundang Hospital, Department of Radiology (Korea, Republic of); Lee, Ji Sung [Soonchunhyang University Medical Center, Biostatistical Consulting Unit (Korea, Republic of); Han, Moon-Ku, E-mail: mkhan@snu.ac.kr [Seoul National University College of Medicine, Department of Neurology, Stroke Center, Seoul National University Bundang Hospital (Korea, Republic of)

    2015-04-15

    PurposeCarotid endarterectomy and stenting are used to treat carotid stenosis, with the volume of carotid artery procedures increasing over the past decade. We investigated the 10-year trend of periprocedural complications with an increasing procedure volume of carotid stenting at a single tertiary hospital.MethodsWe collected 416 consecutive cases (384 patients) of carotid artery stenting performed for either symptomatic (231 cases, 55.5 %) or asymptomatic (185 cases, 44.5 %) internal carotid artery stenosis at a single center. Periprocedural complication was defined as any stroke, myocardial infarction, or death. Procedure-related outcome included any dissection, hemodynamic event, or periprocedural complication.ResultsThe mean age was 68.8 years (82.8 % males; range of 20–89 years); 23.9 % were older than 75 years. Before the procedure, 99.3 and 56.0 % of patients received antiplatelet and lipid-lowering medication, respectively. The overall periprocedural complication rate was 3.6 % (1.6 and 5.2 % in the asymptomatic and symptomatic group, respectively). The composite outcome of any stroke or death was 3.4 %. Periprocedural complication and procedure-related outcome showed a decremental trend with increasing procedure volume, and this trend remained after adjusting for confounders.ConclusionsOur study suggests that carotid stenting at an experienced center might reduce the periprocedural complications. Our periprocedural complication rate of carotid artery stenting may be comparable to, or somewhat lower than, that reported in other clinical trials.

  14. Transradial artery intervention: an alternative approach for renal artery stent implantation?

    Institute of Scientific and Technical Information of China (English)

    LUO Jian-fang; WANG Hui-yong; HUANG Wen-hui; LIU Yuan; LI Guang; ZHOU Ying-ling; CHEN Ji-yan

    2012-01-01

    Background Transfemoral artery access is the main approach for the interventional treatment of renal artery stenosis (RAS).This study aimed to investigate the technical feasibility of a transradial interventional (TRI) treatment of renal artery stenosis.Methods A series of 23 patients who underwent transradial renal artery stenting from October 2010 to October 2011 were studied.Radial sheath system (Terumo,Japan) was used to get access to the radial artery.Radial tourniquet (Terumo) was used to stop bleeding.A 5Fr MPA (COOK,USA) was used to perform selective renal arteriography.Percutaneous renal artery stent systems were used to perform renal artery stenting.Results Renal artery angiography showed that 15 patients had unilateral renal artery stenosis and eight patients had bilateral renal artery stenosis.The descending aorta could not be catheterized in one patient because of the type Ⅲ aortic arch.Twenty-two patients successfully underwent transradial renal artery angiography and the technical success rate was 95.7%.There was no puncture site hematoma or pseudoaneurysm.Mean procedure time was (38.4±7.2) minutes,the mean amount of contrast agent used was (93.2±6.3) ml,and the mean postprocedure bleeding time was (3.2±1.9) minutes.Conclusion Transradial renal artery intervention is technically reliable with less invasion,rapid recovery,fewer complications and may become an alternative intervention approach for the treatment of renal artery stenosis.

  15. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    Science.gov (United States)

    Lee, Cheng-Hung; Jhong, Guan-Heng; Hsu, Ming-Yi; Liu, Shih-Jung; Wang, Chao-Jan; Hung, Kuo-Chun

    2014-05-01

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  16. Acute Carotid Artery Stent Thrombosis Due to Dual Antiplatelet Resistance

    Energy Technology Data Exchange (ETDEWEB)

    Köklü, Erkan, E-mail: drerkankoklu@gmail.com; Arslan, Şakir; Yüksel, İsa Öner; Bayar, Nermin [Antalya Education and Research Hospital, Clinic of Cardiology (Turkey); Koç, Pınar [Antalya Education and Research Hospital, Clinic of Radiology (Turkey)

    2015-08-15

    Carotid artery stenting (CAS) is a revascularization modality that is an alternative to carotid endarterectomy. The efficacy of CAS in primary and secondary prevention from ischemic stroke has been demonstrated in various trials. Acute thrombosis of CAS is a rare complication that can lead to dramatic and catastrophic consequences. We discuss a case of acute CAS thrombosis in a patient who had previously undergone successful CAS. CAS was performed in a 73-year-old man who had had dysarthria lasting 2 weeks with 95 % stenosis in his left internal carotid artery. An acute cerebrovascular event resulting in right-sided hemiplegia developed 24 h after the procedure. Computed tomographic carotid angiography revealed complete occlusion of the stent with thrombus. The cause of stent thrombosis was thought to be antiaggregant resistance to both acetylsalicylic acid and clopidogrel. The most important cause of acute CAS thrombosis is inadequate or ineffective antiaggregant therapy. Evaluating patients who are candidates for CAS for acetylsalicylic acid and clopidogrel resistance may preclude this complication.

  17. Iliac Artery Stent Placement Relieves Claudication in Patients with Iliac and Superficial Femoral Artery Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Ichihashi, Shigeo, E-mail: shigeoichihashi@yahoo.co.jp; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko [Nara Medical University, Department of Radiology (Japan)

    2013-06-15

    Purpose. To evaluate the efficacy of iliac artery stent placement for relief of claudication in patients with both iliac and superficial femoral artery (SFA) lesions. Methods. Stent placement for only iliac artery occlusive disease was performed in 94 limbs (74 patients) with both iliac and SFA occlusive disease on the same limb. All procedures were performed because intermittent claudication did not improve after continuation of antiplatelet medication therapy and home-based exercise for 3 months. Rutherford classification was 2 in 20 limbs and 3 in 74 limbs. Patients with critical limb ischemia were excluded. Median duration of follow-up was 40 months. Primary patency rates of the iliac stent, clinical improvement rates, and risk factors for requiring additional SFA procedures were evaluated. Results. Primary patency rates of the iliac stent at 1, 3, 5, and 7 years were 97, 93, 79, and 79 %, respectively. The initial clinical improvement rate was 87 %. Continued clinical improvement rates at 1, 3, 5, and 7 years were 87, 81, 69, and 66 %, respectively. SFA Trans-Atlantic Inter-Society Consensus (TASC) II C/D lesion was a significant risk factor for requiring additional SFA procedures. Conclusion. Intermittent claudication was relieved by iliac stent placement in most patients with both iliac and SFA lesions. Thus, the indications for treatment of the SFA intended for claudicants should be evaluated after treatment of the iliac lesion.

  18. Renal function after renal artery stenting

    Institute of Scientific and Technical Information of China (English)

    George S. Hanzel; Mark Downes; Peter A. McCullough

    2005-01-01

    @@ Atherosclerotic renal artery stenosis (ARAS), a common clinical finding, is increasing in prevalence as the population ages. ARAS is seen in ~ 7% of persons over 65 years of age1 and in ~ 20% of patients at the time of coronary angiography.2 It is an important cause of chronic kidney disease and may result in 11-14% of cases of end stage renal disease.3

  19. A novel polymer-free ciglitazone-coated vascular stent: in vivo and ex vivo analysis of stent endothelialization in a rabbit iliac artery model

    Science.gov (United States)

    Otto, Sylvia; Jaeger, Kristin; Kolodgie, Frank D.; Muehlstaedt, Diana; Franz, Marcus; Bischoff, Sabine; Schubert, Harald; Figulla, Hans R.; Virmani, Renu; Poerner, Tudor C.

    2016-01-01

    Aim Peroxisome proliferator-activated receptor-gamma (PPARg) agonists have known pleiotropic cardiovascular effects with favourable properties in vascular remodeling, and specifically in suppression of vascular smooth muscle cell proliferation. A novel vascular stent coating using the PPARg ligand ciglitazone (CCS) was investigated regarding its effects on endothelialization after 7 and 28 days. Methods Microporous bare metal stents (BMS) were coated with ciglitazone by ultrasonic flux with a load of 255 μg ciglitazone/stent. SixteenNew Zealand white rabbits, fed a with high cholesterol diet, underwent stent implantation in both iliac arteries. Everolimus-eluting stents (EES) and BMS were comparators. Histology (CD 31 immunostaining, confocal and scanning electron microscopy, morphometry) was performed after 7 and 28 days and by OCT (optical coherence tomography) in vivo after 28 days. Results Microscopy showed comparable results with near complete endothelialization in CCS and BMS (%CD31 above stent struts after 7 days: 67.92±36.35 vs. 84.48±23.86; p = 0.55; endothel % above stent struts: 77.22±27.9 vs. 83.89±27.91; p = 0.78). EES were less endothelialized with minimal fibrin deposition, not found in BMS and CCS (% CD 31 above struts after 28 days, BMS: 100.0±0.0 vs. EES: 95.9±3.57 vs. CCS: 100.0±0.0; p = 0.0292). OCT revealed no uncovered struts in all stents after 28 days. Conclusions Polymer-free coating with ciglitazone, a PPARg agonist is feasible and stable over time. Our data prove unimpaired endothelial coverage of a ciglitazone-coated vascular stent system by histology and OCT. Thus, this PPARg agonist coating deserves further investigation to evaluate its potency on local neointimal suppression. PMID:27613845

  20. Acute stenting and thromboaspiration in basilar artery occlusions due to embolism from the dominating vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Nedeltchev, K.; Remonda, L.; Brekenfeld, C.; Ozdoba, C.; Schroth, G. [Institute of Diagnostic and Interventional Neuroradiology, University of Bern, Inselspital, Freiburgstrasse 4, 3010, Bern (Switzerland); Do, D.D. [Institute of Angiology, University of Bern, Inselspital, Bern (Switzerland); Arnold, M.; Mattle, H.P. [Department of Neurology, University of Bern, Inselspital, Bern (Switzerland)

    2004-08-01

    Intra-arterial thrombolysis (IAT) is the only treatment that has demonstrated benefit in patients with acute basilar artery occlusions (ABAO). IAT may be difficult to perform when access to the occluded basilar artery (BA) is prevented by pathology of the vertebral arteries (VA). We report on two patients with ABAO due to embolism from the dominating VA. Catheter navigation through the occluded VA and thromboaspiration enabled access to the BA. Thromboaspiration alone or in addition to IAT resulted in a complete recanalization of the BA and a favorable clinical outcome. A stent was deployed at the site of the stenosis in the VA either prior to or immediately after BA recanalization. (orig.)

  1. Vertebral artery origin stenting with buddy wire technique in tortuous subclavian artery

    Energy Technology Data Exchange (ETDEWEB)

    Kizilkilic, Osman [Baskent University Department of Radiology, Adana Teaching and Medical Research Center, 01170 Yuregir-Adana (Turkey)]. E-mail: ebos90@hotmail.com

    2007-01-15

    Catheterization of vessels with severe tortuosity and atherosclerotic changes may represent a technical challenge and is associated with a higher incidence of vascular complications [Putman CM, Chaloupka JC. Use of large-caliber coronary guiding catheters for neurointerventional applications. AJNR Am J Neuroradiol 1996;17:697-704]. Placement of guiding catheter to the tortuous subclavian artery in vertebral artery origin stenting procedure is such a condition with difficulties. In the presence of severe tortuosity of aortic arch and proximal subclavian artery placement of guiding catheter may be difficult and yield poor backup support. We describe a technique that uses a buddy wire to make the guiding catheter stable in its proper position and make possible to perform stenting the vertebral artery origin stenosis.

  2. Balloon Angioplasty and Drug Eluting Stenting for Treatment of Peripheral Arterial Occlusive Disease

    Directory of Open Access Journals (Sweden)

    Akın İzgi

    2010-08-01

    Full Text Available Peripheral arterial disease is one of the manifestations of systemic atherosclerosis. In the last decade, remarkable technological advances, especially in the stent area, have shifted revascularization strategies from traditional open surgical approaches toward less morbide percutaneous endovascular treatments. However, even with new designed nitinol bare stents, restenosis remains as the major obstacle of this procedures. More recently, drug eluting stent platforms have been used to treat atherosclerotic peripheral arterial disease. In this article, we reviewed new studies relevant to drug eluting stents for lower extremity peripheral arterial occlusive disease.

  3. Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Tepe, Gunnar; Heller, Stephan; Wiskirchen, Jakub; Fischmann, Arne; Claussen, Claus D. [University of Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Zeller, Thomas [Heart Center, Bad Krotzingen (Germany); Coerper, Stephan; Beckert, Stefan [University of Tuebingen, Department of Surgery, Tuebingen (Germany); Balletshofer, Bernd [University of Tuebingen, Department of Angiology, Tuebingen (Germany)

    2007-08-15

    The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible in all cases. No complications occurred. After the stent implantation, all primarily unsuccessful interventions could be transformed into successful procedures with no residual stenosis >30% in any case. After 6 {+-} 2 months, two of the 18 patients died, and 14 of the 16 remaining patients improved clinically. At follow-up, the patency could be assessed in 14 stented arteries. Three stents were occluded, one stent showed some neointimal hyperplasia (50-70% restenosis), the remaining ten stents showed no restenosis (0-30%). The use of self-expanding nitinol stents in tibioperoneal and popliteal arteries is a safe and feasible option for the treatment of unsuccessful PTA. The 6-months patency is high. (orig.)

  4. In vitro comparison of different carotid artery stents: a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Lettau, Michael; Sauer, Annett; Heiland, Sabine; Rohde, Stefan; Reinhardt, Julia; Bendszus, Martin; Haehnel, Stefan [University of Heidelberg, Medical Center, Division of Neuroradiology, Department of Neurology, Heidelberg (Germany)

    2010-09-15

    CT angiography (CTA) and MR angiography (MRA) are increasingly used methods for evaluation of stented vessel segments. The purpose of this study was to compare CTA, contrast-enhanced MRA (CEMRA) at 1.5 T, and CEMRA at 3 T for the visualization of carotid artery stents and to define the best noninvasive imaging technique for each stent. CTA and CEMRA appearances of 18 carotid artery stents of different designs and sizes (4.0 to 10.0 mm) were investigated in vitro. The profile of the contrast-to-noise ratio (CNR) of the lumen of each stent was calculated semiautomatically by a pixel-by-pixel analysis using the medical imaging software OSIRIS {sup registered}. For each stent, artificial lumen narrowing (ALN) was calculated. In all but one stents, ALN was lower on CEMRA at 3 T than at 1.5 T. With CEMRA at 3 T and at 1.5 T, ALN in most nitinol stents was lower than in the groups of stainless steel and cobalt alloy stents. In most nitinol stents, ALN on CEMRA at 3 T was lower than on CTA. In all stainless steel stents and cobalt alloy stents, ALN was lower on CTA than on CEMRA. With CTA and CEMRA, in most stents ALN decreased with increasing stent diameter. CTA and CEMRA evaluation of vessel patency after stent placement is possible, but considerably impaired by ALN. Investigators should be informed about the method of choice for every stent. (orig.)

  5. Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries

    Energy Technology Data Exchange (ETDEWEB)

    Goltz, J.P.; Kickuth, R. [Universitaetsklinikum Wuerzburg (Germany). Inst. fuer Roentgendiagnostik; Bastuerk, P.; Hoppe, H.; Triller, J. [Universitaetsspital Bern (Switzerland). Inst. fuer Diagnostische, Interventionelle und Paediatrische Radiologie

    2011-07-15

    Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)

  6. Stenting for Atherosclerotic Stenosis of the Intracranial or Skull Base Cerebral Arteries: Effectiveness and Problems

    OpenAIRE

    Harakuni, T.; Hyodo, A.; Shingaki, T.; Kugai, M.; Kinjyo, T.; Tsuchida, H.; Sugimoto, K.; Yoshii, Y.; Matsumaru, Y.

    2004-01-01

    Since May 1992, we have performed percutaneous transluminal angioplasty (PTA) or stenting 70 times for 65 lesions in 62 patients with atherosclerotic stenosis of the intracranial or skull base cerebral arteries. Stenting was carried out nine times for nine lesions in nine cases. Stenting was performed on patients with an average age of 62. The patients were eight men and one woman. The stenotic lesions involved the internal carotid artery (petrous portion) in four cases, the internal carotid ...

  7. Effect and outcome of balloon angioplasty and stenting of the iliac arteries evaluated by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K J; Rasmussen, John Bøje Grønvall; Just, S;

    1999-01-01

    To document the mechanism of percutaneous transluminal angioplasty (PTA) and stenting of the iliac arteries, and to relate the effect to patency.......To document the mechanism of percutaneous transluminal angioplasty (PTA) and stenting of the iliac arteries, and to relate the effect to patency....

  8. Repair of an Atherosclerotic Coronary Artery Aneurysm by Implantation of a Coronary Covered Stent

    Directory of Open Access Journals (Sweden)

    Antenor Portela

    2002-05-01

    Full Text Available An atherosclerotic aneurysm of the right coronary artery complicated by a recent myocardial infarction was successfully treated with coronary artery stenting, using a device consisting of 2 stents with a layer of expandable polytetrafluorethylene (PTFE placed between them. A follow-up angiograph 5 months after the procedure showed sustained initial results.

  9. Subintimal stent placement in patients with long segment occlusion of the iliac artery

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ho Jung; Kim, Young Hwan; Kim, Si Hyung; Ko, Sung Min; Choi, Jin Soo; Lee, Hyun Jin; Kim, Hyung Tae; Jo, Won Hyun [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of)

    2008-01-15

    We evaluated the technical feasibility and clinical efficacy of subintimal stent placement for long segment occlusion of the iliac artery. From March 2003 to February 2007, subintimal stent placement for long segment occlusion of the iliac artery of 24 limbs in 22 patients was analyzed retrospectively. Endovascular access was performed via the ipsilateral femoral artery in 7 cases, via the contralateral femoral artery in 6 cases, via both femoral arteries in 10 cases and via the brachial artery in one case. The SAFARI (subintimal arterial flossing with antegrade-retrograde intervention) technique using a microcatheter was performed to recannalize iliac artery occlusion in three cases. Medical records were reviewed for the collection of follow-up data. The stent patency rate was analyzed by use of the Kaplan-Meier method. Subintimal stent placement was technically successful in 23 of 24 procedures (95.8%). The mean ankle-brachial index (ABI) increased form 0.26 to 0.82. The Fontaine classification was improved after stent placement in all patients. Major complications occurred in four procedures: three distal embolizations and one arterial rupture. All of the complications were successfully treated by endovascular intervention. The primary stent patency rates at 6-months, 1-, 2-and 3-years were 95%, 88%, 88% and 88%, respectively. Subintimal stent placement is a safe and effective treatment for long segment occlusion of the iliac artery.

  10. Six-month results of a biodegradable polymer and rapamycin-coating stent for coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    Yuxiao ZHANG; Caiyi LU; Qiao XUE; Peng LIU; Wei YAN; Rui CHEN

    2006-01-01

    Objective To assess the safety and efficacy of a novel biodegradable polymer and rapamycin-coating stent, the EXCEL stent, in the treatment of coronary artery disease (CAD), as compared with the CypherTM stent. Methods In this prospective, non-randomized study, 60 consecutive patients with symptomatic CAD received either an EXCEL stent (n=32), or a CypherTM stent(n=28),according to their respective treatment intention. Follow-up angiography was performed at a mean of 180±40 days. The primary endpoint of the study was the occurrence of a major adverse cardiac event (MACE), including death, myocardial infarction, or target-vessel revascularization during the 6 months after stenting. The secondary end points included the in-stent late luminal loss (LLL), percentage of in-stent stenosis of the luminal diameter, and the rate of restenosis (luminal narrowing of 50 percent or more) at 6 months. Results There were no significant differences between the two groups in baseline characteristics, including the distribution of target vessel and lesion types. During the follow up period of 6 months, there were no occurrences of MACE in either group. Twenty-seven patients(84%) in the EXCEL group and 10 (36 %) in the CypherTM group underwent quantitative coronary angiography at 6 months. For these patients, no restenosis occurred, and there were no differences in the in-stent stenosis of the luminal diameter (5.98±5.52% vs 5.21 ±6.3%,P>0.05) and the LLL (-0.02±0.09 mm vs -0.01±0.07 mm, P>0.05). Conclusions Compared with the CypherTM stent, the EXCEL Stent with biodegradable polymer and rapamycin-coating showed similar efficacy in the prevention of neointimal proliferation, restenosis, and associated clinical events in CAD patients.

  11. CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kuya, Keita; Shinohara, Yuki; Fujii, Shinya; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological Therapeutic Science, Faculty of Medicine, Yonago (Japan); Sakamoto, Makoto; Watanabe, Takashi [Tottori University, Division of Neurosurgery, Department of Brain and Neurosciences, Faculty of Medicine, Yonago (Japan); Iwata, Naoki; Kishimoto, Junichi [Tottori University, Division of Clinical Radiology Faculty of Medicine, Yonago (Japan); Kaminou, Toshio [Osaka Minami Medical Center, Department of Radiology, Osaka (Japan)

    2014-11-15

    Follow-up CT angiography (CTA) is routinely performed for post-procedure management after carotid artery stenting (CAS). However, the stent lumen tends to be underestimated because of stent artifacts on CTA reconstructed with the filtered back projection (FBP) technique. We assessed the utility of new iterative reconstruction techniques, such as adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR), for CTA after CAS in comparison with FBP. In a phantom study, we evaluated the differences among the three reconstruction techniques with regard to the relationship between the stent luminal diameter and the degree of underestimation of stent luminal diameter. In a clinical study, 34 patients who underwent follow-up CTA after CAS were included. We compared the stent luminal diameters among FBP, ASIR, and MBIR, and performed visual assessment of low attenuation area (LAA) in the stent lumen using a three-point scale. In the phantom study, stent luminal diameter was increasingly underestimated as luminal diameter became smaller in all CTA images. Stent luminal diameter was larger with MBIR than with the other reconstruction techniques. Similarly, in the clinical study, stent luminal diameter was larger with MBIR than with the other reconstruction techniques. LAA detectability scores of MBIR were greater than or equal to those of FBP and ASIR in all cases. MBIR improved the accuracy of assessment of stent luminal diameter and LAA detectability in the stent lumen when compared with FBP and ASIR. We conclude that MBIR is a useful reconstruction technique for CTA after CAS. (orig.)

  12. Drug delivery patterns for different stenting techniques in coronary bifurcations: a comparative computational study.

    Science.gov (United States)

    Cutrì, Elena; Zunino, Paolo; Morlacchi, Stefano; Chiastra, Claudio; Migliavacca, Francesco

    2013-08-01

    The treatment of coronary bifurcation lesions represents a challenge for the interventional cardiologists due to the lower rate of procedural success and the higher risk of restenosis. The advent of drug-eluting stents (DES) has dramatically reduced restenosis and consequently the request for re-intervention. The aim of the present work is to provide further insight about the effectiveness of DES by means of a computational study that combines virtual stent implantation, fluid dynamics and drug release for different stenting protocols currently used in the treatment of a coronary artery bifurcation. An explicit dynamic finite element model is developed in order to obtain realistic configurations of the implanted devices used to perform fluid dynamics analysis by means of a previously developed finite element method coupling the blood flow and the intramural plasma filtration in rigid arteries. To efficiently model the drug release, a multiscale strategy is adopted, ranging from lumped parameter model accounting for drug release to fully 3-D models for drug transport to the artery. Differences in drug delivery to the artery are evaluated with respect to local drug dosage. This model allowed to compare alternative stenting configurations (namely the Provisional Side Branch, the Culotte and the Inverted Culotte techniques), thus suggesting guidelines in the treatment of coronary bifurcation lesions and addressing clinical issues such as the effectiveness of drug delivery to lesions in the side branch, as well as the influence of incomplete strut apposition and overlapping stents.

  13. Nitinol Stent Oversizing in Patients Undergoing Popliteal Artery Revascularization: A Finite Element Study.

    Science.gov (United States)

    Gökgöl, Can; Diehm, Nicolas; Nezami, Farhad Rikhtegar; Büchler, Philippe

    2015-12-01

    Nitinol stent oversizing is frequently performed in peripheral arteries to ensure a desirable lumen gain. However, the clinical effect of mis-sizing remains controversial. The goal of this study was to provide a better understanding of the structural and hemodynamic effects of Nitinol stent oversizing. Five patient-specific numerical models of non-calcified popliteal arteries were developed to simulate the deployment of Nitinol stents with oversizing ratios ranging from 1.1 to 1.8. In addition to arterial biomechanics, computational fluid dynamics methods were adopted to simulate the physiological blood flow inside the stented arteries. Results showed that stent oversizing led to a limited increase in the acute lumen gain, albeit at the cost of a significant increase in arterial wall stresses. Furthermore, localized areas affected by low Wall Shear Stress increased with higher oversizing ratios. Stents were also negatively impacted by the procedure as their fatigue safety factors gradually decreased with oversizing. These adverse effects to both the artery walls and stents may create circumstances for restenosis. Although the ideal oversizing ratio is stent-specific, this study showed that Nitinol stent oversizing has a very small impact on the immediate lumen gain, which contradicts the clinical motivations of the procedure.

  14. A randomized, controlled, multicenter trial to evaluate the safety and efficacy of Zotarolimus- vs. Paclitaxel-eluting stents in de novo occlusive lesions in coronary arteries

    DEFF Research Database (Denmark)

    Chevalier, Bernard; Dimario, Carlo; Neumann, Franz-Josef;

    2013-01-01

    The ZOMAXX I trial tested the noninferiority of a zotarolimus-eluting coronary stent (ZoMaxx(™) ) when compared with a paclitaxel-eluting coronary stent (Taxus(™) Express(2™) ) in a randomized trial of percutaneous intervention for de novo coronary artery stenosis. Angiographic analysis at the pr...

  15. A suggested training programme for carotid artery stenting (CAS)

    Energy Technology Data Exchange (ETDEWEB)

    Gaines, Peter [Sheffield Vascular Institute, Northern General Hospital, Sheffield S5 7AU (United Kingdom)]. E-mail: P.A.gaines@Sheffield.ac.uk; Nicholson, Tony [Leeds Teaching Hospitals NHS Trust, Great George St., Leeds LS13EX (United Kingdom)]. E-mail: tonynick@tonynick.karoo.co.uk

    2006-10-15

    Carotid artery stenting as an alternative to traditional carotid endartrectomy is becoming increasingly important in the treatment of transient ischemic attack and stroke. Physicians from several different medical disciplines are interested in treating appropriate patients by this method. Patients are entitled to know what training and experience the surgeon or clinician has before giving consent. This should involve endovascular experience in all systems and experience and knowledge of cerebral angiography and intervention. A multidisciplinary approach and reporting of adverse events is vital for patient safety.

  16. DISCOVER: Dutch Iliac Stent trial: COVERed balloon-expandable versus uncovered balloon-expandable stents in the common iliac artery: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Bekken Joost A

    2012-11-01

    Full Text Available Abstract Background Iliac artery atherosclerotic disease may cause intermittent claudication and critical limb ischemia. It can lead to serious complications such as infection, amputation and even death. Revascularization relieves symptoms and prevents these complications. Historically, open surgical repair, in the form of endarterectomy or bypass, was used. Over the last decade, endovascular repair has become the first choice of treatment for iliac arterial occlusive disease. No definitive consensus has emerged about the best endovascular strategy and which type of stent, if any, to use. However, in more advanced disease, that is, long or multiple stenoses or occlusions, literature is most supportive of primary stenting with a balloon-expandable stent in the common iliac artery (Jongkind V et al., J Vasc Surg 52:1376-1383,2010. Recently, a PTFE-covered balloon-expandable stent (Advanta V12, Atrium Medical Inc., Hudson, NH, USA has been introduced for the iliac artery. Covering stents with PTFE has been shown to lead to less neo-intimal hyperplasia and this might lower restenosis rates (Dolmatch B et al. J Vasc Interv Radiol 18:527-534,2007, Marin ML et al. J Vasc Interv Radiol 7:651-656,1996, Virmani R et al. J Vasc Interv Radiol 10:445-456,1999. However, only one RCT, of mediocre quality has been published on this stent in the common iliac artery (Mwipatayi BP et al. J Vasc Surg 54:1561-1570,2011, Bekken JA et al. J Vasc Surg 55:1545-1546,2012. Our hypothesis is that covered balloon-expandable stents lead to better results when compared to uncovered balloon-expandable stents. Methods/Design This is a prospective, randomized, controlled, double-blind, multi-center trial. The study population consists of human volunteers aged over 18 years, with symptomatic advanced atherosclerotic disease of the common iliac artery, defined as stenoses longer than 3 cm and occlusions. A total of 174 patients will be included. The control group will undergo

  17. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheng-Hung [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China); Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Jhong, Guan-Heng [Graduate Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan (China); Hsu, Ming-Yi; Wang, Chao-Jan [Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, Taiwan (China); Liu, Shih-Jung, E-mail: shihjung@mail.cgu.edu.tw [Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Hung, Kuo-Chun [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China)

    2014-05-28

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  18. New stent developments for peripheral arterial occlusive disease; Neue Stententwicklungen fuer die periphere arterielle Verschlusskrankheit

    Energy Technology Data Exchange (ETDEWEB)

    Tepe, G. [Romed Kliniken, Klinikum Rosenheim, Institut fuer Diagnostische und Interventionelle Radiologie, Rosenheim (Germany)

    2010-01-15

    Infrainguinal peripheral occlusive disease is increasingly being treated by endovascular techniques. Bare metal stainless steel, self-expanding nitinol stents, drug-eluting and covered stents (stent grafts) are becoming increasingly more important adjuncts to percutaneous translumninal angioplasty in the treatment of peripheral artery disease. In this article the available evidence supporting the use of stents in the femoropopliteal and tibial arteries will be described as well as their limitations. Future stent developments will also be discussed. (orig.) [German] Die endovaskulaere Therapie spielt bei der Therapie der peripheren arteriellen Verschlusskrankheit (PAVK) eine wichtige Rolle. Unbeschichtete ballonexpandierbare Stahlstents, selbstexpandierende Nitinolstents sowie medikamentenbeschichtete und ''covered stents'' (Stentgrafts) haben eine zunehmende Bedeutung als Zusatztherapie zusammen mit der primaeren Ballonangioplastie gewonnen. In diesem Artikel wird die klinische Evidenz beschrieben, die die Anwendung von Stents im Bereich der femoropoplitealen und tibialen Strombahn unterstuetzt. Limitationen sowie zukuenftige Stententwicklungen werden ebenfalls diskutiert. (orig.)

  19. Finite element analyses for design evaluation of biodegradable magnesium alloy stents in arterial vessels

    Energy Technology Data Exchange (ETDEWEB)

    Wu Wei [Laboratory of Biological Structure Mechanics, Structural Engineering Department, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan (Italy); Gastaldi, Dario, E-mail: dario.gastaldi@polimi.it [Laboratory of Biological Structure Mechanics, Structural Engineering Department, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan (Italy); Yang Ke; Tan Lili [Division of Specialized Materials and Devices, Institute of Metal Research, Chinese Academy of Sciences, Shenyang (China); Petrini, Lorenza; Migliavacca, Francesco [Laboratory of Biological Structure Mechanics, Structural Engineering Department, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan (Italy)

    2011-12-15

    Biodegradable magnesium alloy stents (MAS) can provide a great benefit for diseased vessels and avoid the long-term incompatible interactions between vessels and permanent stent platforms. However, the existing MAS showed insufficient scaffolding to the target vessels due to short degradation time. In this study, a three dimensional finite element model combined with a degradable material model of AZ31 (Al 0.03, Zn 0.01, Mn 0.002 and Mg balance, mass percentage) was applied to three different MAS designs including an already implanted stent (Stent A), an optimized design (Stent B) and a patented stent design (Stent C). One ring of each design was implanted through a simulation in a vessel model then degraded with the changing interaction between outer stent surface and the vessel. Results showed that a proper stent design (Stent B) can lead to an increase of nearly 120% in half normalized recoil time of the vessel compared to the Stent A; moreover, the expectation that the MAS design, with more mass and optimized mechanical properties, can increase scaffolding time was verified numerically. The Stent C has more materials than Stent B; however, it only increased the half normalized recoil time of the vessel by nearly 50% compared to the Stent A because of much higher stress concentration than that of Stent B. The 3D model can provide a convenient design and testing tool for novel magnesium alloy stents.

  20. Treatment of Ruptured Vertebral Artery Dissecting Aneurysms Distal to the Posterior Inferior Cerebellar Artery: Stenting or Trapping?

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Yi-Bin, E-mail: fangyibin@163.com; Zhao, Kai-Jun, E-mail: zkjwcfzwh@163.com; Wu, Yi-Na, E-mail: wuyina0923@163.com; Zhou, Yu, E-mail: yzhou-2011@126.com; Li, Qiang, E-mail: lqeimm@126.com; Yang, Peng-Fei, E-mail: 15921196312@163.com; Huang, Qing-Hai, E-mail: ocinhqh@163.com; Zhao, Wen-Yuan, E-mail: doczhaowy@163.com; Xu, Yi, E-mail: xuyichyy@163.com; Liu, Jian-Min, E-mail: chstroke@163.com [Second Military Medical University, Department of Neurosurgery, Changhai Hospital (China)

    2015-06-15

    PurposeThe treatment of ruptured vertebral artery dissecting aneurysms (VADAs) continues to be controversial. Our goal was to evaluate the safety, efficacy, and long-term outcomes of internal trapping and stent-assisted coiling (SAC) for ruptured VADAs distal to the posterior inferior cerebellar artery (supra-PICA VADAs), which is the most common subset.MethodsA retrospective review was conducted of 39 consecutive ruptured supra-PICA VADAs treated with internal trapping (n = 20) or with SAC (n = 19) at our institution. The clinical and angiographic data were retrospectively compared.ResultsThe immediate total occlusion rate of the VADAs was 80 % in the trapping group, which improved to 88.9 % at the follow-ups (45 months on average). Unwanted occlusions of the posterior inferior cerebellar artery (PICA) were detected in three trapped cases. Incomplete obliteration of the VADA or unwanted occlusions of the PICA were detected primarily in the VADAs closest to the PICA. In the stenting group, the immediate total occlusion rate was 47.4 %, which improved to 100 % at the follow-ups (39 months on average). The immediate total occlusion rate of the VADAs was higher in the trapping group (p < 0.05), but the later total occlusion was slightly higher in the stenting group (p > 0.05).ConclusionsOur preliminary results showed that internal trapping and stent-assisted coiling are both technically feasible for treating ruptured supra-PICA VADAs. Although not statistically significant, procedural related complications occurred more frequently in the trapping group. When the VADAs are close to the PICA, we suggest that the lesions should be treated using SAC.

  1. Transradial artery Palmaz-Schatz coronary stent implantation: results of a single-center feasibility study.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J

    1995-07-01

    The purpose of this study was to evaluate the feasibility and safety of implantation of unsheathed Palmaz-Schatz coronary stents introduced via the radial artery. Anticoagulation after coronary stenting carries the risk of vascular complications if large-bore guiding catheters are introduced via the femoral artery. These complications have serious local sequelae and lead to suboptimal anticoagulation and prolonged hospitalization. By combining 6F guiding catheters and low-profile dilatation catheters mounted with Palmaz-Schatz stents, smaller vessels such as the radial artery can be selected as the entry site. It is hypothesized that with this technique major puncture site-related complications rarely occur because hemostasis is easily achieved and because no veins and nerves are near this artery. With the double blood supply to the hand, radial artery occlusion is well tolerated. In 100 consecutive patients, stent implantation was attempted for 122 lesions in 104 vessels. Immediately after stent implantation and final angiography, the introducer sheath was withdrawn and intense anticoagulation and mobilization initiated. The radial artery puncture site was studied by two-dimensional and Doppler ultrasound. Successful stent implantation via the radial artery was achieved in 96 patients. In 2 patients, arterial puncture failed but was followed by successful stenting via another entry site. In 1 patient, stent implantation was achieved with a stent delivery system via the femoral artery after a failed attempt to cross the lesion with a bare stent via the radial approach, complicated by groin bleeding requiring transfusions and vascular surgery.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Comparison of in-hospital and long-term outcomes between a Cypher stent and a Taxus stent in Chinese diabetic patients with coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    YANG Yue-jin; WU Yong-jian; LIU Hai-bo; YOU Shi-jie; LI Jian-jun; DAI Jun; GAO Run-lin; XU Bo; KANG Sheng; PEI Wei-dong; CHEN Ji-lin; QIAO Shu-bin; QIN Xue-wen; YAO Min; CHEN Jue

    2007-01-01

    Background The sirolimus and paclitaxel distribution patterns and tissue residence time may be modified in atherosclerotic lesions for patients with diabetes, and the biological mechanisms of action for these agents differ significantly. Previous clinical trials have yielded discrepant results of major adverse cardiac events and restenosis between a sirolimus-eluting stent and a paclitaxel-eluting stent in coronary artery disease. Therefore, this study was conduced to compare in-hospital and long-term clinical outcomes between patients receiving sirolimus-eluting stent(Cypher or Cypher Select stent) and paclitaxel-eluting stent (Taxus Express stent) after percutaneous intervention (PCI)in Chinese patients with diabetes.Methods One hundred and sixty-four consecutive diabetic patients underwent PCI in Fuwai Hospital from April 2004 to December 2004. Of them, 101 patients received Cypher or Cypher Select stents (Cypher group, 145 stents) and 63patients received Taxus Express stents (Taxus group, 129 stents). Repeat coronary angiography was performed at6-month and clinical outcomes were evaluated at 1- and 3-year follow-up. Stent thrombosis was classified according to Academic Research Consortium (ARC).Results The two groups did not differ significantly with respect to cardiac death, recurrent myocardial infarction (re-MI),target vessel revascularization (TVR) and occurrence of major adverse cardiac events (MACE). And the MACE-free cumulative survival at 1- and 3-year follow-up and early, late and very late thrombosis rates were also similar in the two groups (all P>0.05). There was a trend favoring PES over SES with regard to reducing cardiac death (0 vs 2.0%,P=0.524), re-MI (0 vs 2.0%, P=0.524), the composite of the cardiac death and re-MI (0 vs 4.0%, P=0.299) and very late thrombosis (0 vs 3.0%, P=0.295) between 1-year and 3-year follow-up.Conclusion The study indicates that PCI with either Cypher or Taxus stents is associated with similar efficacy and safety in

  3. Carotid artery stenting by non-femoral arterial approach in patients with difficult anatomy

    Directory of Open Access Journals (Sweden)

    R V Narayana

    2013-01-01

    Full Text Available Background: Carotid endarterectomy (CEA and carotid artery stenting (CAS are safe, effective, and standard methods to treat significant carotid artery stenosis. CAS is generally performed through femoral arterial access. We had six patients with significant carotid artery stenosis, who had difficult anatomy prohibiting a trans-femoral CAS. Those patients were given an option for CEA. However, they refused for surgical intervention. Aim: We investigated the feasibility of performing CAS from a non-femoral arterial approach in patients with difficult anatomies like severe aortic/aorto-iliac disease, tortuous aortic arch, and tortuous carotid artery origin. Materials and Methods: Six patients with difficult anatomy presented to us with either transient ischemic attack or stroke with high-grade carotid artery stenosis. Out of the six patients, three had aorto-iliac disease, one had high-grade coarctation of aorta, two had tortuous aortic arch and or tortuous carotid artery origin. All these patients were treated with CAS though non-femoral arterial route. Results: CAS could be done successfully in all these six patients; four of them were done through trans-brachial arterial route and two were done through a direct carotid artery puncture. There were no new neurological deficits seen in any of the patient post-procedure. Conclusion: CAS can be done safely through non-femoral arterial approach in patients with difficult anatomy.

  4. Hepatic artery stent-grafts for the emergency treatment of acute bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Bellemann, Nadine, E-mail: nadine.bellemann@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sommer, Christof-Matthias; Mokry, Theresa; Kortes, Nikolas; Gnutzmann, Daniel; Gockner, Theresa; Schmitz, Anne [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Weitz, Jürgen [Department of Surgery, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Department for Visceral, Thoracic and Vascular Surgery at the University Hospital, Technical University Dresden (Germany); Kauczor, Hans-Ulrich; Radeleff, Boris; Stampfl, Ulrike [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)

    2014-10-15

    Highlights: • We report our experiences with stent-grafts for the treatment of acute hemorrhage from the hepatic artery or the stump of the gastroduodenal artery. • The technical success of stent-graft implantation was 88%. • The bleeding ceased immediately after stent-graft implantation in 88%. • The complication rate was 21%. - Abstract: Purpose: We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. Methods: Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. Results: In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n = 16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4 mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. Conclusions: Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.

  5. Corrosion resistance improvement for 316L stainless steel coronary artery stents by trimethylsilane plasma nanocoatings.

    Science.gov (United States)

    Eric Jones, John; Chen, Meng; Yu, Qingsong

    2014-10-01

    To improve their corrosion resistance and thus long-term biocompatibility, 316L stainless steel coronary artery stents were coated with trimethylsilane (TMS) plasma coatings of 20-25 nm in thickness. Both direct current (DC) and radio-frequency (RF) glow discharges were utilized for TMS plasma coatings and additional NH₃/O₂ plasma treatment to tailor the surface properties. X-ray photoelectron spectroscopy (XPS) was used to characterize the coating surface chemistry. It was found that both DC and RF TMS plasma coatings had Si- and C-rich composition, and the O- and N-contents on the surfaces were substantially increased after NH₃/O₂ plasma treatment. Surface contact angle measurements showed that DC TMS plasma nanocoating with NH₃/O₂ plasma treatment generated very hydrophilic surface. The corrosion resistance of TMS plasma coated stents was evaluated through potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques. The potentiodynamic polarization demonstrated that the TMS plasma coated stents imparted higher corrosion potential and pitting potential, as well as lower corrosion current densities as compared with uncoated controls. The surface morphology of stents before and after potentiodynamic polarization testing was analyzed with scanning electron microscopy, which indicated less corrosion on coated stents than uncoated controls. It was also noted that, from EIS data, the hydrophobic TMS plasma nanocoatings showed stable impedance modulus at 0.1 Hz after 21 day immersion in an electrolyte solution. These results suggest improved corrosion resistance of the 316L stainless steel stents by TMS plasma nanocoatings and great promise in reducing and blocking metallic ions releasing into the bloodstream.

  6. Paraplegia after aortic and superior mesenteric artery stenting for occlusive disease.

    Science.gov (United States)

    Hans, Sachinder S; Ngo, William; McAllister, Michael

    2014-02-01

    Paraplegia after endovascular therapy for aortic and visceral artery occlusive disease is an extremely uncommon occurrence. Two cases of paraplegia after placement of an aortic covered stent for infrarenal aortic stenosis and a superior mesenteric artery stent for chronic visceral ischemia are presented. In both patients, embolization of the arterial supply to the spinal cord was the presumed cause. One patient had a slight recovery after intense physical therapy and rehabilitation. The second patient did not have any recovery from her paraplegia.

  7. Randomized clinical trial comparing abluminal biodegradable polymer sirolimus-eluting stents with durable polymer sirolimus-eluting stents

    Science.gov (United States)

    Zhang, Haijun; Wang, Xiangfei; Deng, Wei; Wang, Shenguo; Ge, Junbo; Toft, Egon

    2016-01-01

    Abstract Background: The biodegradable polymer drug-eluting stents (DES) were developed to improve vascular healing. However, further data and longer-term follow-up are needed to confirm safety and efficacy of these stents. This randomized clinical trial aimed to compare safety and efficacy of 2 sirolimus-eluting stents (SES): Cordimax—a novel abluminal biodegradable polymer SES and Cypher Select—a durable polymer SES, at 9 months angiographic and 5-year clinical follow-up. Methods: We randomized 402 patients with coronary artery disease to percutaneous coronary intervention with Cordimax (n = 202) or Cypher select (n = 200). Angiographic follow-up was performed at 9 months after the index procedure and clinical follow-up annually up to 5 years. The primary endpoint was angiographic in-stent late luminal loss (LLL). Secondary endpoints included angiographic restenosis rate, target vessel revascularization (TVR), and major adverse cardiac events (MACEs; defined as cardiac death, myocardial infarction, or TVR) at 5-year follow-up. Results: Cordimax was noninferior to Cypher select for in-stent LLL (0.25 ± 0.47 vs 0.18 ± 0.49 mm; P = 0.587) and in-stent mean diameter stenosis (22.19 ± 12.21% vs 19.89 ± 10.79%; P = 0.064) at 9 months angiographic follow-up. The MACE rates were not different at 1 year (5.9% vs 4.0%, P = 0.376); however, MACE rates from 2 to 5 years were lower in the Cordimax group (6.8% vs 13.1%; P = 0.039). Conclusion: Abluminal biodegradable polymer SES is noninferior to durable polymer SES at 9-month angiographic and 1-year clinical follow-up. However, MACE rates from 2 to 5 years were less in the abluminal biodegradable polymer group. PMID:27661023

  8. Carotid artery stenting via transbrachial approach; Stenting der Arteria carotis interna ueber den transbrachialen Zugang

    Energy Technology Data Exchange (ETDEWEB)

    Tietke, M.W.; Ulmer, S.; Riedel, C.; Jansen, O. [Inst. fuer Neuroradiologie, UKSH Campus Kiel (Germany)

    2008-11-15

    Purpose: the transbrachial approach as an alternative access site for carotid artery stenting (CAS) has mainly been published as case reports. This paper evaluates transbrachial CAS at our institute for the past 5 years and refers to the complications and results of this method. Materials and methods: from January 2003 to April 2008, we performed 299 CAS of which 12 (4%, 11 male, 1 female) were performed with a transbrachial approach. The average age of these patients was 67.4 years ({+-}9.75). The average degree of stenosis of the treated carotid artery was assessed by Doppler ultrasound (81.5% {+-} 10.66) and digital subtraction angiography (DSA) using the NASCET criteria (75.9% {+-} 9.75). 9/12 patients (75%) were treated because of symptomatic stenosis. Results: the transbrachial approach was performed in 8 patients because of high-grade stenosis of the femoral and/or iliac arteries. 4 patients showed severe elongation of the aortic arch. 11 of 12 (92%) of the transbrachial CAS were performed successfully. The approach was judged to be only slightly more challenging than puncture of the femoral artery. No minor or major complications occurred at the access site. 3 of 11 patients (27%) showed residual stenosis after CAS of 24% ({+-}7.78). (orig.)

  9. Improved outcomes of elderly patients treated with drug-eluting versus bare metal stents in large coronary arteries

    DEFF Research Database (Denmark)

    Kurz, David J; Bernheim, Alain M; Tüller, David

    2015-01-01

    BACKGROUND: Drug-eluting stents (DES) improve outcomes in elderly patients with small coronary artery disease compared with bare-metal stents (BMS), but randomized data in elderly patients in need of large coronary stents are not available. METHODS: Planned secondary analysis of patients ≥75 years...... recruited to the "BASKET-PROVE" trial, in which 2,314 patients undergoing percutaneous coronary intervention for large (≥3.0 mm) native vessel disease were randomized 2:1 to DES (everolimus- vs sirolimus-eluting stents 1:1) versus BMS. All patients received 12 months of dual antiplatelet therapy....... The primary end point was a composite of cardiac death or nonfatal myocardial infarction at 2 years. RESULTS: Comparison of DES versus BMS among 405 patients ≥75 years showed significantly lower rates of the primary end point for DES (5.0% vs 11.6%; hazard ration (HR) 0.64 [0.44-0.91]; P = .014). Rates...

  10. Drug-eluting stents in the management of peripheral arterial disease.

    Science.gov (United States)

    Bosiers, Marc; Cagiannos, Catherine; Deloose, Koen; Verbist, Jürgen; Peeters, Patrick

    2008-01-01

    Since major meta-analyses of randomized controlled trials in interventional cardiology showed the potential of drug-eluting stents in decreasing restenosis and reintervention rates after coronary artery stenting, one of the next steps in the treatment of arterial occlusive disease is the transfer of the active coating technology towards peripheral arterial interventions. In this manuscript, we aim to provide a literature overview on available peripheral (lower limb, renal, and supra-aortic) drug-eluting stent applications, debate the cost implications, and give recommendations for future treatment strategies.

  11. Osteonecrosis of Femoral Head Occurred after Stent Placement of Femoral Artery

    Directory of Open Access Journals (Sweden)

    Akiyoshi Shimatani

    2014-01-01

    Full Text Available We present a case of osteonecrosis of femoral head (ONFH that occurred after stent angiography of femoral artery for the treatment of arteriosclerosis obliterans (ASO of left inferior limb in a 76-year-old woman. No case of late collapse of femoral head as a complication of endovascular procedure such as stent placement has been previously documented. We considered that ONFH occurred after detaining stent at a junction of left deep femoral artery for the treatment of the ischemia of left lateral and medial femoral circumflex artery.

  12. Relationship of Albuminuria and Renal Artery Stent Outcomes: Results From the CORAL Randomized Clinical Trial (Cardiovascular Outcomes With Renal Artery Lesions).

    Science.gov (United States)

    Murphy, Timothy P; Cooper, Christopher J; Pencina, Karol M; D'Agostino, Ralph; Massaro, Joseph; Cutlip, Donald E; Jamerson, Kenneth; Matsumoto, Alan H; Henrich, William; Shapiro, Joseph I; Tuttle, Katherine R; Cohen, David J; Steffes, Michael; Gao, Qi; Metzger, D Christopher; Abernethy, William B; Textor, Stephen C; Briguglio, John; Hirsch, Alan T; Tobe, Sheldon; Dworkin, Lance D

    2016-11-01

    Randomized clinical trials have not shown an additional clinical benefit of renal artery stent placement over optimal medical therapy alone. However, studies of renal artery stent placement have not examined the relationship of albuminuria and treatment group outcomes. The CORAL study (Cardiovascular Outcomes in Renal Atherosclerotic Lesions) is a prospective clinical trial of 947 participants with atherosclerotic renal artery stenosis randomized to optimal medical therapy with or without renal artery stent which showed no treatment differences (3(5.8% and 35.1% event rate at mean 43-month follow-up). In a post hoc analysis, the study population was stratified by the median baseline urine albumin/creatinine ratio (n=826) and analyzed for the 5-year incidence of the primary end point (myocardial infarction, hospitalization for congestive heart failure, stroke, renal replacement therapy, progressive renal insufficiency, or cardiovascular disease- or kidney disease-related death), for each component of the primary end point, and overall survival. When baseline urine albumin/creatinine ratio was ≤ median (22.5 mg/g, n=413), renal artery stenting was associated with significantly better event-free survival from the primary composite end point (73% versus 59% at 5 years; P=0.02), cardiovascular disease-related death (93% versus 85%; P≤ 0.01), progressive renal insufficiency (91% versus 77%; P=0.03), and overall survival (89% versus 76%; P≤0.01), but not when baseline urine albumin/creatinine ratio was greater than median (n=413). These data suggest that low albuminuria may indicate a potentially large subgroup of those with renal artery stenosis that could experience improved event-free and overall-survival after renal artery stent placement plus optimal medical therapy compared with optimal medical therapy alone. Further research is needed to confirm these preliminary observations.

  13. Loss of bifurcation patency after cross-over stenting of ostial lesions in superficial femoral artery: possible causes, prevention and reintervention

    Institute of Scientific and Technical Information of China (English)

    Jiang Junhao; Chen Bin; Dong Zhihui; Shi Yun; Li Weimiao; Yue Jianing

    2014-01-01

    Background Crossover stenting across the origin of the profunda femoral artery (PFA) and occasionally into the common femoral artery (CFA) is commonly used after suboptimal balloon angioplasty of ostial occlusive lesions of the superficial femoral artery (SFA) involving the bifurcation.Late stent occlusion at the bifurcation is not rare and results in severe lower extremity ischemia.Therefore,we tried to assess its possible causes,prevention and reintervention.Methods Using a prospectively maintained single-center database,12-month femoral bifurcation patency was retrospectively compared and lesion and procedural predictors of stent occlusion were determined among 63 patients (64 lesions) who between July 2011 and February 2013 underwent crossover (36 non-jailed and 15 jailed SFA,and 12 distal and 1 complete CFA) stenting of de novo ostial SFA lesions.Results Twelve-month overall patency rate at the femoral bifurcation was 88%,with no significant difference between jailed-ostial SFA (80%) and distal CFA (67%) stenting (P=0.731),and significant differences between either and non-jailed ostial stenting (100%,P=0.035 and 0.002).When PFA ostium was jailed by the stent,patients with preexisting CFA or PFA lesions had a 12-month bifurcation patency rate of 20%,significantly lower than those with simple ostial SFA lesions (83%,P=0.015).Stent induced intimal hyperplasia caused bifurcation occlusion in 6 surgical reintervention cases.Conclusions In crossover stenting of ostial lesions in SFA,bifurcation patency loss was significantly higher in distal CFA and jailed ostial SFA stenting than non-jailed ostial SFA stenting.Preexisting CFA or PFA lesion is a significant risk factor for bifurcation patency loss when PFA ostium is jailed by crossover stenting.

  14. Contralateral approach to iliac artery recanalization with kissing nitinol stents present in the aortic bifurcation.

    Science.gov (United States)

    Joseph, George; Hooda, Amit; Thomson, Viji Samuel

    2015-01-01

    A 69-year-old man, who had earlier undergone reconstruction of the aortic bifurcation with kissing nitinol stents, presented with occlusion of the left external iliac artery. The occlusion was successfully and safely recanalized using contralateral femoral approach with passage of interventional hardware through the struts of the stents in the aortic bifurcation. Presence of contemporary flexible nitinol stents with open-cell design in the aortic bifurcation is not a contraindication to the use of the contralateral femoral approach.

  15. Optical coherence tomography assessment of edge dissections after drug-eluting stent implantation in coronary artery

    Institute of Scientific and Technical Information of China (English)

    GUO Jun; HAN Bao-shi; GAI Lu-yue; YANG Ting-shu; CHEN Yun-dai; TIAN Feng; LIU Hong-bin; CHEN Lian; SUN Zhi-jun; REN Yi-hong; JIN Qin-hua; LIU Chang-fu

    2012-01-01

    Background Edge dissections after coronary stent implantation are associated with increased short-term risk of major adverse cardiovascular events.The incidence and outcome of edge dissections after coronary stent implantation were reportedly different using different imaging techniques.We used optical coherence tomography (OCT) to assess the incidence,morphological findings and related factors of edge dissections after drug-eluting stent (DES) implantation.Methods Totally 42 patients with 43 de novo lesions in 43 native arteries undergoing DES implantation with OCT imaging were enrolled in this study.Results Nine edge dissections were detected in 43 arteries after DES implantation.There were four morphological patterns of stent edge dissections indentified in this study:(1) superficial intimal tears (n=3),(2) subintimal dissections (n=4),(3) split of media (n=1),(4) disruption of the fibrotic cap of plaque (n=1).Stent edge expansion and stent expansion were both higher in the group with dissections than those in the group without dissections (1.682±0.425 vs.1.229±0.285,P=0.0290; 1.507±0.445 vs.1.174±0.265,P=0.0072).Conclusions The incidence of stent edge dissections detected by OCT was 21%.Stent edge dissection is related with stent edge expansion and stent expansion.

  16. Simultaneous occlusion of left anterior descending and left circumflex arteries by very late stent thrombosis: vascular response to drug-eluting stents assessed by intravascular ultrasound.

    Science.gov (United States)

    Yamawaki, Masahiro; Onuma, Yoshinobu; Nakano, Masatsugu; Muramatsu, Takashi; Nakatani, Shimpei; Ishibashi, Yuki; Ishimori, Hiroshi; Hirano, Keisuke; Ito, Yoshiaki; Tsukahara, Reiko; Muramatsu, Toshiya

    2015-11-01

    Very late stent thrombosis (VLST) is a catastrophic complication after implantation of a drug-eluting stent (DES). It has been reported that VLST is associated with pathological changes, which often include late acquired incomplete stent apposition (LAISA) with thrombus formation. In addition, the vascular response to the stent (evaginations, neointimal growth, and thrombosis) and the incidence of LAISA are reported to vary among the different types of DES. We experienced a patient with cardiogenic shock induced by simultaneous VLST of both the left anterior descending artery (LAD) and the left circumflex artery (LCX) at 3 years after implantation of two sirolimus-eluting stents. Intravascular ultrasound (IVUS) showed LAISA of both arteries. A paclitaxel-eluting stent, which had been implanted in the right coronary artery 3 years earlier, did not show such a finding. IVUS revealed "different vascular reactions" to "different types of DES" in this patient.

  17. ILIAC-ARTERY URETERAL-FISTULA ASSOCIATED WITH AN INDWELLING URETERAL STENT

    NARCIS (Netherlands)

    ZWEERS, HMM; VANDRIEL, MF; MENSINK, HJA

    1991-01-01

    We report on a patient with an ureteroiliac artery fistula, which developed after double J stenting. The stent was introduced because of unilateral hydronephrosis 2 months after a Wertheim-Meigs operation preceded by cesium application. The presenting symptom of gross hematuria was initially misjudg

  18. Percutaneous cervical carotid artery access with stenting of the left internal carotid artery in an elderly patient

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    To describe the successful endovascular treatment in a nonagenarian with symptomatic internal carotid artery stenosis using direct carotid artery access. An independent 98 year-old man was admitted to our hospital for symptoms of progressive weakness with disorientation and dysphasia. Carotid Duplex ultrasonography was performed which revealed a totally occluded right internal carotid artery and high grade stenosis of the left internal carotid artery by velocities of 608/240 cm/sec. The patient refused surgical endarterectomy and thus he was referred for carotid artery stenting. Using the femoral artery approach and multiple catheter techniques, access to the common carotid artery could not be accomplished safely. The procedure was aborted and he was therefore brought back to the catheterization laboratory the following day for direct carotid access. Carotid artery stenting was accomplished by using of a 6F sheath percutaneously in the left common carotid, cerebral protection device (CPD) and a Nitinol stent. The patient was discharged the following day without complications. At 14 months follow-up the patient is functional and independent without recurrence of symptoms. Carotid artery stenting via direct access can be accomplished in patients when the femoral artery approach is anatomically prohibitive. In this case of advanced age and the patient's refusal for surgery, direct carotid access was his only option.

  19. Telescoping Dual Covered Stent Graft Construct for Endovascular Treatment of a Giant Extracranial Carotid Artery Pseudoaneurysm.

    Science.gov (United States)

    Ding, Dale; Starke, Robert M; Moriarty, Maurice; Brew, Stefan

    2016-12-01

    Large pseudoaneurysms which compress the parent vessel are challenging lesions to successfully treat with endovascular therapy. We describe the endovascular treatment of a giant extracranial carotid artery (ECCA) pseudoaneurysm resulting in substantial mass effect on the common carotid artery (CCA) bifurcation using a telescoping dual covered stent graft construct. A 56-year-old male was diagnosed with an 8.5 cm × 13 cm pseudoaneurysm arising from the left CCA bifurcation, which was causing luminal narrowing of the CCA and proximal internal carotid artery (ICA). The patient underwent endovascular intervention, during which a balloon-expandable covered stent was deployed within a heparin-bonded covered stent, such that the overall construct spanned from the CCA to the lower cervical ICA. The employment of a telescoping dual covered stent technique can successfully treat appropriately selected patients with large or giant ECCA pseudoaneurysms, with the concomitant goals of excluding the pseudoaneurysm and restoring the luminal caliber of the parent artery.

  20. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    Energy Technology Data Exchange (ETDEWEB)

    Stoupis, Christoforos [University of Berne, Inselspital, Department of Diagnostic, Interventional and Pediatric Radiology, Berne (Switzerland); Kreisspital, Radiology, Maennedorf (Switzerland); Ludwig, Karin; Triller, Juergen [University of Berne, Inselspital, Department of Diagnostic, Interventional and Pediatric Radiology, Berne (Switzerland); Inderbitzin, Daniel [University of Berne, Inselspital, Clinic for Visceral and Transplantation Surgery, Berne (Switzerland); Do, Dai-Do [University of Berne, Inselspital, Clinic for Angiology, Berne (Switzerland)

    2007-02-15

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  1. Surface chemical and physical modification in stent technology for the treatment of coronary artery disease.

    Science.gov (United States)

    Nazneen, Feroze; Herzog, Grégoire; Arrigan, Damien W M; Caplice, Noel; Benvenuto, Pasquale; Galvin, Paul; Thompson, Michael

    2012-10-01

    Coronary artery disease (CAD) kills millions of people every year. It results from a narrowing of the arteries (stenosis) supplying blood to the heart. This review discusses the merits and limitations of balloon angioplasty and stent implantation, the most common treatment options for CAD, and the pathophysiology associated with these treatments. The focus of the review is heavily placed on research efforts geared toward the modification of stent surfaces for the improvement of stent-vascular compatibility and the reduction in the occurrence of related pathophysiologies. Such modifications may be chemical or physical, both of which are surveyed here. Chemical modifications may be passive or active, while physical modification of stent surfaces can also provide suitable substrates to manipulate the responses of vascular cells (endothelial, smooth muscle, and fibroblast). The influence of micro- and nanostructured surfaces on the in vitro cell response is discussed. Finally, future perspectives on the combination of chemical and physical modifications of stent surfaces are also presented.

  2. Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Vejlstrup, Niels Grove; Ahtarovski, Kiril Aleksov;

    2012-01-01

    Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year. This case...... report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology. While...

  3. New techniques for intracranial stent navigation in patients with tortuous arteries

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyun Wook; Koo, Young Baek; Lee, Tae Hong; Kim, Hak Jin; Lee, Jun Woo; Kim, Chang Won; Kim, Suk; Choo, Ki Seok; Jeong, Yeon Joo; Lee, Suk Hong [Pusan National University Hospital, Pusan (Korea, Republic of)

    2005-07-15

    We wanted to describe several new techniques of intracranial stenting that are helpful for navigating the stent delivery system in the tortuous carotid or vertebral arteries. Between May 1998 and June 2004, 65 patients with 73 symptomatic, stenotic intracranial arteries (more than 50%) were successfully treated with stent-assisted angioplasty. In eleven of the total cases, the standard technique failed to navigate the stent delivery system into the objective lesion because of the tortuous path of the carotid or vertebral arteries. In these cases, several new techniques were used to overcome the vessels' tortuous path. The several new techniques were 1) the waiting method (20-30 minutes) after advancement of microwire across the lesion; 2) the double wires technique using an additional microwire; and 3) the coaxial double guiding catheters technique using an additional smaller guiding catheter. Five lesions were located in the middle cerebral arteries, four were in the supraclinoid internal carotid arteries, and two were in the distal vertebral arteries. In all difficult cases, intracranial artery stenting was performed successfully by using the several new techniques. The waiting method made smooth stent navigation possible in 5 cases, the double wire technique was successful in 4 cases and the coaxial double guiding catheter technique was successful in 2 case. There was no complication related to the new techniques. In difficult cases where the standard technique failed to navigate the stent delivery system into the objective lesion because of the vessels' tortuous path, these new techniques for intracranial stent navigation were usefully implemented.

  4. Evaluation of restenosis, renal function and blood pressure after the renal artery stenting in patients with atherosclerosis renovascular disease

    Institute of Scientific and Technical Information of China (English)

    王焱

    2006-01-01

    Objective To evaluate the restenosis, renal function and blood pressure after renal artery stenting in patients with atherosclerosis renovascular disease. Methods Percutaneous renal artery stent (PTRAS) was performed in 135 patients with single or bilateral renal artery stenosis (≥70%). Clinical data of above patients were studied during follow-up period. Results A total of 147

  5. Towards a self-reporting coronary artery stent--measuring neointimal growth associated with in-stent restenosis using electrical impedance techniques.

    Science.gov (United States)

    Shedden, Laurie; Kennedy, Simon; Wadsworth, Roger; Connolly, Patricia

    2010-10-15

    Implantable medical devices have become the standard method for treating a variety of cardiovascular diseases (NICE, 2003, 2009), such as coronary artery disease, where coronary artery stents are the device of choice (Fischman et al., 1994; Babapulle et al., 2004). One post-operative problem with these devices is the long-term monitoring of the device-tissue interface, with respect to the complications that often arise from in-stent restenosis. This monitoring, where it is available, is currently performed using imaging techniques such as contrast angiography, IVUS, CT and MRI. In this study we propose an alternative method for the non-invasive monitoring of restenosis in coronary artery stents. This preliminary study uses impedance spectroscopy to measure the electrical impedance of cells and tissues associated with the neointimal growth that characterises in-stent restenosis in coronary artery stents. An in vitro organ culture model, using a stent implanted in a section of pig coronary artery, simulated tissue growth inside a stent. Impedance measurements were made regularly over a 28-day culture period. In a novel step, the stent itself was employed as an electrode. Differences in electrical impedance could be seen between control (stent alone) and artery-embedded stents in culture, which were associated with the presence of biological tissue. This method could potentially be developed to produce a stent that was capable of self-reporting in-stent restenosis. The advantages of such a device would be that monitoring could be non-invasively and easily carried out, allowing more routine follow-ups and the early identification and management of any device complications.

  6. Drug-eluting stents in the management of peripheral arterial disease

    Directory of Open Access Journals (Sweden)

    Marc Bosiers

    2008-06-01

    Full Text Available Marc Bosiers1, Catherine Cagiannos1, Koen Deloose1, Jürgen Verbist2, Patrick Peeters21Department of Vascular Surgery, AZ St-Blasius, Dendermonde, Belgium; 2Department of Cardiovascular and Thoracic Surgery, Imelda Hospital, Bonheiden, BelgiumAbstract: Since major meta-analyses of randomized controlled trials in interventional cardiology showed the potential of drug-eluting stents in decreasing restenosis and reintervention rates after coronary artery stenting, one of the next steps in the treatment of arterial occlusive disease is the transfer of the active coating technology towards peripheral arterial interventions. In this manuscript, we aim to provide a literature overview on available peripheral (lower limb, renal, and supra-aortic drug-eluting stent applications, debate the cost implications, and give recommendations for future treatment strategies.Keywords: critical limb ischemia, drug-eluting stent, below the knee, infrapopliteal, crural, limb salvage

  7. Computational replication of the patient-specific stenting procedure for coronary artery bifurcations: From OCT and CT imaging to structural and hemodynamics analyses.

    Science.gov (United States)

    Chiastra, Claudio; Wu, Wei; Dickerhoff, Benjamin; Aleiou, Ali; Dubini, Gabriele; Otake, Hiromasa; Migliavacca, Francesco; LaDisa, John F

    2016-07-26

    The optimal stenting technique for coronary artery bifurcations is still debated. With additional advances computational simulations can soon be used to compare stent designs or strategies based on verified structural and hemodynamics results in order to identify the optimal solution for each individual's anatomy. In this study, patient-specific simulations of stent deployment were performed for 2 cases to replicate the complete procedure conducted by interventional cardiologists. Subsequent computational fluid dynamics (CFD) analyses were conducted to quantify hemodynamic quantities linked to restenosis. Patient-specific pre-operative models of coronary bifurcations were reconstructed from CT angiography and optical coherence tomography (OCT). Plaque location and composition were estimated from OCT and assigned to models, and structural simulations were performed in Abaqus. Artery geometries after virtual stent expansion of Xience Prime or Nobori stents created in SolidWorks were compared to post-operative geometry from OCT and CT before being extracted and used for CFD simulations in SimVascular. Inflow boundary conditions based on body surface area, and downstream vascular resistances and capacitances were applied at branches to mimic physiology. Artery geometries obtained after virtual expansion were in good agreement with those reconstructed from patient images. Quantitative comparison of the distance between reconstructed and post-stent geometries revealed a maximum difference in area of 20.4%. Adverse indices of wall shear stress were more pronounced for thicker Nobori stents in both patients. These findings verify structural analyses of stent expansion, introduce a workflow to combine software packages for solid and fluid mechanics analysis, and underscore important stent design features from prior idealized studies. The proposed approach may ultimately be useful in determining an optimal choice of stent and position for each patient.

  8. 53. Bilateral ductal stenting for nonconfluent pulmonary arteries in a newborn

    Directory of Open Access Journals (Sweden)

    K. Al Dhahri

    2016-07-01

    Full Text Available Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Limited data available for bilateral PDA stenting. Bilateral PDA stenting in nonconfluent pulmonary arteries is challenging procedure but can be considered as an option in the management of complex conditions like this. 12 days old Preterm (36 weeks gestation male baby with birth weight of 2.6 kg developed respiratory distress with severe cyanosis and desaturation upto 50%. Baby was intubated and started on Prostaglandin 0.05 mic/kg/mt. His saturation improved to 80%. Echocardiogram showed complex cyanotic heart disease, Situs ambiguous, dextrocardia, complete unbalanced AV septal defect, pulmonary atresia , nonconfluent small branch pulmonary arteries supplied by the bilateral patent ductus arteriosus (PDA from right aortic arch and all four pulmonary veins form a confluence and drain into superior vena cava(SVC through vertical vein with no obstruction. Baby was taken up for PDA stenting. descending aortogram showed right aortic arch with vertical tortuous duct to right pulmonary artery (RPA and another short duct with acute angle from left subclavian artery to left pulmonary artery (LPA . Both ducti stented with coronary stents. Vertical vein angiogram showed both lungs drain to a confluence and then to SVC via ascending vertical vein with no obstruction. After stenting lung perfusion improved and the baby was stable and maintained 80% saturation on room air. Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Our case is unique with Heterotaxy, TAPVC, Dextrocardia and double ducti. Eventhough bilateral ductal stenting is technically challenging it is successful through femoral artery approach.

  9. Percutaneous transradial artery approach for coronary Palmaz-Schatz stent implantation.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J

    1994-07-01

    The purpose of this study was to evaluate feasibility, safety, and efficacy of implantation of unsheathed Palmaz-Schatz coronary stents via the radial artery. Anticoagulation after coronary stenting has the hazard of vascular complications if large-bore guiding catheters are introduced via the femoral artery. Such complications have serious local sequelae, are associated with suboptimal anticoagulation, and prolong hospitalization. By combining 6F guiding catheters and low-profile dilatation catheters with bare Palmaz-Schatz stents, smaller vessels such as the radial artery can be selected as the entry site. It is postulated that no major puncture site-related complications occur because hemostasis is easily achieved and no veins and nerves are near the radial artery. With double blood supply to the hand, radial artery occlusion is well tolerated. Twenty-five bare Palmaz-Schatz stents were implanted via the radial artery through 6F guiding catheters in 20 consecutive patients for venous bypass graft stenosis (n = 9; 45%), native coronary artery restenosis (n = 7; 35%) and suboptimal transradial artery PTCA (n = 4; 20%). Immediately after stent implantation and assessment of the result by means of computerized quantitative coronary analysis, the arterial sheath was withdrawn followed by intense anticoagulation and free ambulation of the patient. Radial artery function and anatomy were assessed by two-dimensional and Doppler ultrasound examination. Lesions (n = 24) were of type A (n = 13; 54%), B (n = 6; 25%) and C (n = 5; 21%). The reference diameter of the stented segments was 3.2 +/- 0.5 mm (2.2 to 4.2 mm).(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Drug-coated balloons are replacing the need for nitinol stents in the superficial femoral artery.

    Science.gov (United States)

    Kitrou, Panagiotis; Karnabatidis, Dimitrios; Katsanos, Konstantinos

    2016-08-01

    Amassed evidence from several randomized controlled trials and high quality meta-analyses clearly support the primary use of paclitaxel-coated balloons (PCB) in the superficial femoral artery over traditional plain balloon angioplasty or primary bare nitinol stenting with significantly lower vascular restenosis, less need for repeat procedures, improved quality of life and potential cost savings for the healthcare system. Stents may be reserved for bail-out in case of a suboptimal dilatation result, and for selected more complex lesions, or in case of critical limb ischemia in order to eliminate vessel recoil and maximize immediate hemodynamic gain. Debulking atherectomy remains unproven, but holds a lot of promise in particular in combination with PCBs, in order to improve compliance of the vessel wall by plaque removal, allow for a better angioplasty result and optimize drug transfer and bioavailability. The present overview summarizes and discusses current evidence about femoropopliteal PCB angioplasty compared to the historical standard of plain old balloon angioplasty and bare nitinol stents. Available evidence is appraised in the context of clinically meaningful results, relevant unresolved issues are highlighted, and future trends are discussed.

  11. RX Herculink Elite® renal stent system: a review of its use for the treatment of renal artery stenosis

    Directory of Open Access Journals (Sweden)

    Colyer Jr

    2012-08-01

    Full Text Available William R Colyer JrDivision of Cardiovascular Medicine, University of Toledo Medical Center, Toledo, OH, USAAbstract: The management of renal artery stenosis (RAS remains controversial. While some evidence suggests that treatment with stent placement is beneficial, randomized trials have failed to demonstrate a significant benefit. Ongoing clinical trials should help to better define the role for stenting of RAS while avoiding limitations seen with earlier trials. When it comes to stenting for RAS, several stents have been used; however, many stents which have been used previously and which are still being used are biliary stents that are used “off-label.” These stents have typically come onto the market through the 510(k pathway. To date, a total of five stents have been approved by the United States Food and Drug Administration for use in the renal arteries. Of the five stents that have received approval, the Bridge™ Extra Support (Medtronic CardioVascular, Santa Rosa, CA and the Palmaz® (Cordis Corporation, Bridgewater, NJ stents are no longer available. Currently, the Express® SD (Boston Scientific, Natick, MA, Formula™ (Cook Medical, Bloomington, IN, and Herculink Elite® (Abbott Vascular, Santa Clara, CA stents are Food and Drug Administration approved and available for use. The Herculink Elite is the most recently approved of the renal stents, having received approval in late 2011. The Herculink Elite stent is the only cobalt chromium stent approved for use in the renal arteries. Although trial data are limited and direct comparisons among renal stents is not possible, the Herculink Elite stent has demonstrated good performance. Additionally, the design of the Herculink Elite offers some advantages that may translate into improved outcomes.Keywords: renal artery stenosis, stenting, FDA approval

  12. Patient with Recent Coronary Artery Stent Requiring Major Non Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Usha Kiran

    2009-01-01

    Full Text Available Anaesthesiologists are increasingly confronted with patients who had a recent coronary artery stent implanta-tion and are on dual anti-platelet medication. Non cardiac surgery and most invasive procedures increase the risk of stent thrombosis especially when procedure is performed early after stent implantation. Anaesthesiologist faces the dilemma of stopping the antiplatelet therapy before surgery to avoid bleeding versus perioperative stent thrombosis. Individualized approach should be adopted with following precautions. i In a surgical patient with a history of percu-taneous coronary intervention (PCI and coronary stent, determine the date of the procedure, the kind of the stent inserted and the possibility of complications during the procedure. ii Consider all patents with a recent stent implan-tation (e.g. less than three months for bare metal stents and less than one year for brachytherapy or drug eluting stents as high risk and consult an interventional cardiologist. iii Any decision to postpone surgery, continue, modify or discontinue antiplatelet regimes must involve the cardiologist, anaesthesiologist, surgeon, haematologist and the intensivist to balance the risk and benefit of each decision.

  13. Rapid Formation of Cerebral Microbleeds after Carotid Artery Stenting

    Directory of Open Access Journals (Sweden)

    Kousuke Kakumoto

    2012-03-01

    Full Text Available Background: Recent studies reported that cerebral microbleeds (CMBs, i.e. small areas of signal loss on T2*-weighted gradient-echo (GE imaging, could develop rapidly after acute ischemic stroke. We hypothesized that CMBs rapidly emerge after carotid artery stenting (CAS. Objective: We investigated the frequency of and predisposing factors for CMBs after CAS. Methods: We retrospectively examined MRI before and after CAS in 88 consecutive patients (average age: 71.7 ± 7.2 years, average rates of carotid stenosis: 72.6 ± 12.8% who underwent CAS for carotid artery stenosis between March 1, 2009, and September 30, 2010. We defined new CMBs as signal losses that newly appeared on the follow-up GE. We examined the association of new CMBs with demographics, risk factors, and baseline MBs. Results: Among 88 patients, 18 (20.5% had CMBs initially, and 7 (8.0% developed new CMBs right after CAS. New CMBs appeared on the same side of CAS in all of the 7 patients. New CMBs appeared significantly more frequently in the CMB-positive group than in the CMB-negative one (22% vs. 4%, p = 0.03 on the pre-CAS MRI. Multivariate analysis also revealed that the presence of CMBs before CAS was an independent predictor of new development of CMBs after CAS (odds ratio: 8.09, 95% confidence interval: 1.39–47.1. Conclusion: CMBs can develop rapidly after CAS, especially in patients with pre-existing CMBs. Since the existence of CMBs prior to CAS suggests a latent vascular damage which is vulnerable to hemodynamic stress following CAS, particular attention should be paid to the prevention of intracerebral hemorrhage due to hyperperfusion after CAS.

  14. Emergency endovascular repair of iliac artery rupture caused by post-stenting angioplasty with an endograft

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yu-bin; WU Dan-ming; XU Ke; WANG Cheng-gang; YI Wei; JIA Qi; SUN Yu-xin

    2007-01-01

    @@ Iliac artery rupture is a rare complication of poststenting angioplasty and can lead to massive lifethreatening haemorrhage. Conventional surgery can not repair the damaged vessel easily and may cause substantial blood loss and high operative morbidity and mortality. We report our experience with a selfexpanding covered endoprosthesis for endovascular repair of the rupture of an iliac artery caused by stenting angioplasty.

  15. Influence of carotid artery stenting on cognitive function

    Energy Technology Data Exchange (ETDEWEB)

    Quasar Grunwald, Iris [Saarland University Clinic, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Department of Neuroradiology, Homburg (Germany); Papanagiotou, Panagiotis; Backens, Martin; Politi, Maria; Vedder, Verena; Zercher, K. [Saarland University Clinic, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Reith, Wolfgang; Supprian, Tilman; Muscalla, B.; Haass, Anton; Krick, Christoph M. [Saarland University Clinic, Clinic for Neurology, Homburg (Germany); Saarland University Clinic, Clinic for Psychiatry and Psychotherapy, Homburg (Germany)

    2010-01-15

    There have only been a few studies on cognitive changes in patients with carotid occlusive disease, and the results of these show major discrepancies in the extent to which treatment affects neuropsychological function. We sought to clarify these discrepancies by evaluating the effects of carotid artery stenting (CAS) on the cognitive function. Forty-one asymptomatic CAS patients were administered a test battery of neuropsychological tests measuring cognitive speed and memory function before and 3 months after the procedure. A control group was also evaluated. To test for thromboembolic lesions, diffusion-weighted imaging was used. CAS led to a significant increase in cognitive speed (p < 0.001) but did not afford any change in memory function. This was regardless of the degree or side of stenosis or patient age or gender. CAS significantly improved functions that involve cognitive speed. Earlier studies did not differentiate between speed and memory tests and thus might have missed these changes. Further studies correlating changes in brain perfusion with increase in cognitive speed are needed. (orig.)

  16. A finite element study of balloon expandable stent for plaque and arterial wall vulnerability assessment

    Science.gov (United States)

    Karimi, Alireza; Navidbakhsh, Mahdi; Razaghi, Reza

    2014-07-01

    The stresses induced within plaque tissues and arterial layers during stent expansion inside an atherosclerotic artery can be exceeded from the yield stresses of those tissues and, consequently, lead to plaque or arterial layer rupture. The distribution and magnitude of the stresses in each component involved in stenting might be clearly different for different plaque types and different arterial layers. In this study, a nonlinear finite element simulation was employed to investigate the effect of plaque composition (calcified, cellular, and hypocellular) on the stresses induced in the arterial layers (intima, media, and adventitia) during implantation of a balloon expandable coronary stent into a stenosed artery. The atherosclerotic artery was assumed to consist of a plaque and normal/healthy arterial tissues on its outer side. The results indicated a significant influence of plaque types on the maximum stresses induced within the plaque wall and arterial layers during stenting but not when computing maximum stress on the stent. The stress on the stiffest calcified plaque wall was in the fracture level (2.38 MPa), whereas cellular and hypocellular plaques remain stable owing to less stress on their walls. Regardless of plaque types, the highest von Mises stresses were observed on the stiffest intima layer, whereas the lowest stresses were seen to be located in less stiff media layer. The computed stresses on the intima layer were found to be high enough to initiate a rupture in this stiff layer. These findings suggest a higher risk of arterial vascular injury for the intima layer, while a lower risk of arterial injury for the media and adventitia layers.

  17. Emergency stenting to control massive bleeding of injured iliac artery following lumbar disk surgery

    Energy Technology Data Exchange (ETDEWEB)

    Bierdrager, Edwin; Rooij, Willem Jan van; Sluzewski, Menno [Department of Radiology, St. Elisabeth Ziekenhuis, Tilburg (Netherlands)

    2004-05-01

    The purpose of this study was to demonstrate the use of endovascular stenting to repair an iliac artery injury following lumbar discectomy, thus obviating the need for major surgery. A 57-year-old woman developed a distended abdomen and signs of hypovolemic shock immediately following discectomy at the L4-L5 level. Ultrasound showed a large amount of abdominal fluid. Angiography revealed a laceration of the right iliac artery bifurcation with extravasation of contrast material. After occlusion of the internal iliac artery with fibered coils to prevent retrograde flow to the iliac bifurcation, a self-expanding covered stent was inserted to seal the iliac laceration. The leakage of blood stopped immediately. The clinical condition of the patient gradually improved and she was discharged home 5 weeks later. Sealing of arterial laceration as a complication of lumbar disc surgery with a covered stent is a simple and effective alternative to major pelvic surgery. (orig.)

  18. Relationship between the Direction of Ophthalmic Artery Blood Flow and Ocular Microcirculation before and after Carotid Artery Stenting

    Directory of Open Access Journals (Sweden)

    Masashi Ishii

    2016-01-01

    Full Text Available When internal carotid artery stenosis is accompanied by ocular ischemic syndrome, intervention is recommended to prevent irreversible visual loss. In this study, we used laser speckle flowgraphy to measure the ocular microcirculation in the optic nerve head before and after carotid artery stenting (CAS of 40 advanced internal carotid stenosis lesions from 37 patients. The aim was to investigate the relationship between ocular microcirculation and the direction of ophthalmic artery blood flow obtained by angiography. We found that there was a significant increase in blood flow after CAS (P=0.003. Peak systolic velocity as an indicator of the rate of stenosis was also significantly higher in the group with retrograde/undetected flow of the ophthalmic artery than in the group with antegrade flow (P=0.002. In all cases where retrograde flow of the ophthalmic artery was observed before stenting, the flow changed to antegrade after stenting. Through the use of laser speckle flowgraphy, this study found that CAS can improve ocular microcirculation. Furthermore, while patients displaying retrograde flow of the ophthalmic artery before stenting have a poor prognosis, CAS corrected the flow to antegrade, suggesting that visual loss can be prevented by improving the ocular microcirculation.

  19. Percutaneous stenting of the superior mesenteric artery for the treatment of chronic mesenteric ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Gweon, Hye Mi; Suh, Sang Hyun; Won, Jong Yun [Yongdong Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, Do Yun [Yonsei National College of Medicine, Seoul (Korea, Republic of); Kim, Sam Soo [Kangwon National University Hospital, Chuncheon (Korea, Republic of)

    2008-06-15

    We wanted to evaluate the effectiveness of stent placement on the superior mesenteric artery as a treatment for chronic mesenteric ischemia. Seven patients (mean age: 55 years, age range: 43-66 years) with chronic mesenteric ischemia were enrolled between March 2000 and September 2003. All the patients underwent pre-procedure contrast enhanced computerized tomography to evaluate for occlusion or stenosis of the mesenteric arteries and they then underwent an angiographic procedure. A balloon-expandable metal stent was placed in the superior mesenteric artery, and this was combined with balloon angioplasty and thrombolysis. We evaluated the angiographic and procedural success after the procedures. Angiographic and procedural success was obtained in 100% of the patients and the clinical symptoms improved in 100% of the patients. The patency at 6-months and 1-year was 85% and 71%, respectively. The mean follow-up period was 12 months (range: 1-25 months). During the follow-up period, ischemic symptoms recurred in 2 patients, and restenosis in a stent was confirmed with angiography; one patient was successfully treated by stent placement in the celiac artery and the other patient died due to extensive mesenteric thrombosis. For the treatment of chronic mesenteric ischemia, percutaneous stent placement on the superior mesenteric artery showed a favorable result and it was an effective alternative to surgery for the high-risk patients.

  20. Novel A20-gene-eluting stent inhibits carotid artery restenosis in a porcine model

    Directory of Open Access Journals (Sweden)

    Zhou ZH

    2016-08-01

    Full Text Available Zhen-hua Zhou,1 Jing Peng,1 Zhao-you Meng,1 Lin Chen,1 Jia-Lu Huang,1 He-qing Huang,1 Li Li,2 Wen Zeng,2 Yong Wei,2 Chu-Hong Zhu,2 Kang-Ning Chen1 1Department of Neurology, Cerebrovascular Disease Research Institute, Southwest Hospital, 2Department of Anatomy, Key Laboratory for Biomechanics of Chongqing, Third Military Medical University, Chongqing, People’s Republic of China Background: Carotid artery stenosis is a major risk factor for ischemic stroke. Although carotid angioplasty and stenting using an embolic protection device has been introduced as a less invasive carotid revascularization approach, in-stent restenosis limits its long-term efficacy and safety. The objective of this study was to test the anti-restenosis effects of local stent-mediated delivery of the A20 gene in a porcine carotid artery model.Materials and methods: The pCDNA3.1EHA20 was firmly attached onto stents that had been collagen coated and treated with N-succinimidyl-3-(2-pyridyldithiolpropionate solution and anti-DNA immunoglobulin fixation. Anti-restenosis effects of modified vs control (the bare-metal stent and pCDNA3.1 void vector stents were assessed by Western blot and scanning electron microscopy, as well as by morphological and inflammatory reaction analyses.Results: Stent-delivered A20 gene was locally expressed in porcine carotids in association with significantly greater extent of re-endothelialization at day 14 and of neointimal hyperplasia inhibition at 3 months than stenting without A20 gene expression.Conclusion: The A20-gene-eluting stent inhibits neointimal hyperplasia while promoting re-endothelialization and therefore constitutes a novel potential alternative to prevent restenosis while minimizing complications. Keywords: restenosis, A20, gene therapy, stent, endothelialization

  1. Computer modeling of restenosis and heating stent thermal effects in the coronary artery

    OpenAIRE

    Zdravković-Petrović, Nataša; Nikolić, Dalibor; Milošević, Žarko; Themis, Exarchos; Parodi, Oberdan; Filipović, Nenad; id_orcid 0000-0001-9964-5615

    2013-01-01

    The understanding and the prediction of the evolution of atherosclerotic plaques either into vulnerable plaques or into stable plaques are very important for the medical community. Stents in the coronary arteries are routinely used in the management of patients with angina or myocardial infarction where percutaneous coronary intervention is the clinically appropriate procedure. In this study we analysed stent deployment in the specific patient and simulation of the temperature distribution fo...

  2. Conformally integrated stent cell resonators for wireless monitoring of peripheral artery disease

    KAUST Repository

    Viswanath, Anupam

    2013-01-01

    This paper presents the design and in vitro evaluation of magnetoelastic sensors intended for wireless monitoring of tissue accumulation in peripheral artery stents. The sensors, shaped like stent cells, are fabricated from 28-μm thick foils of magnetoelastic Ni-Fe alloy and are conformally integrated with the stent. The typical sensitivity to viscosity is 427 ppm/cP over a 1.1-8.6 cP range. The sensitivity to mass loading is typically 63,000-65000 ppm/mg with resonant frequency showing an 8.1% reduction for an applied mass that is 15% of the unloaded mass of the sensor. © 2013 IEEE.

  3. Effects of Crimping on Mechanical Performance of Nitinol Stent Designed for Femoral Artery: Finite Element Analysis

    Science.gov (United States)

    Nematzadeh, F.; Sadrnezhaad, S. K.

    2013-11-01

    Nitinol stents are used to minimize improper dynamic behavior, low twistability, and inadequate radial mechanical strength of femoral artery stents. In this study, finite element method is used to investigate the effect of crimping and Austenite finish temperature ( A f) of Nitinol on mechanical performance of Z-shaped open-cell femoral stent under crimping conditions. Results show that low A f Nitinol has better mechanical and clinical performance due to small chronic outward force, large radial resistive force, and appropriate superelastic behavior.

  4. Evaluation of flow velocities after carotid artery stenting through split spectrum Doppler optical coherence tomography and computational fluid dynamics modeling.

    Science.gov (United States)

    Vuong, Barry; Genis, Helen; Wong, Ronnie; Ramjist, Joel; Jivraj, Jamil; Farooq, Hamza; Sun, Cuiru; Yang, Victor X D

    2014-12-01

    Hemodynamics plays a critical role in the development of atherosclerosis, specifically in regions of curved vasculature such as bifurcations exhibiting irregular blood flow profiles. Carotid atherosclerotic disease can be intervened by stent implantation, but this may result in greater alterations to local blood flow and consequently further complications. This study demonstrates the use of a variant of Doppler optical coherence tomography (DOCT) known as split spectrum DOCT (ssDOCT) to evaluate hemodynamic patterns both before and after stent implantation in the bifurcation junction in the internal carotid artery (ICA). Computational fluid dynamics (CFD) models were constructed to simulate blood velocity profiles and compared to the findings achieved through ssDOCT images. Both methods demonstrated noticeable alterations in hemodynamic patterns following stent implantation, with features such as slow velocity regions at the neck of the bifurcation and recirculation zones at the stent struts. Strong correlation between CFD models and ssDOCT images demonstrate the potential of ssDOCT imaging in the optimization of stent implantation in the clinical setting.

  5. Computational fluid dynamics evaluation of incomplete stent apposition in a tapered artery

    Science.gov (United States)

    Poon, Eric; Thondapu, Vikas; Ooi, Andrew; Hayat, Umair; Barlis, Peter; Moore, Stephen

    2015-11-01

    Coronary stents are deployed to prop open blocked arteries and restore normal blood flow, however in-stent restenosis (ISR) and stent thrombosis (ST) remain possibly catastrophic complications. Computational fluid dynamics (CFD) analyses can elucidate the pathological impact of alterations in coronary hemodynamics and correlate wall shear stress (WSS) with atherosclerotic processes. The natural tapering of a coronary artery often leads to proximal incomplete stent apposition (ISA) where stent struts are not in contact with the vessel wall. By employing state-of-the-art computer-aided design (CAD) software, generic open-cell and closed-cell coronary stent designs were virtually deployed in an idealised tapered coronary artery. Pulsatile blood flow (80 mL/min at 75 beats/min) was carried out numerically on these CAD models using a finite volume solver. CFD results reveal significant fluctuations in proximal WSS and large recirculation regions in the setting of proximal ISA, resulting in regions of high wall shear stress gradient (WSSG) that have been previously linked to poor endothelial cell coverage and vascular injury. The clinical significance of these proximal high WSSG regions will be correlated with findings from high-resolution in-vivo imaging. Supported by the Australian Research Council (LP120100233) and Victorian Life Sciences Computation Initiative (VR0210).

  6. In vivo imaging of superficial femoral artery (SFA) stents for deformation analysis

    Science.gov (United States)

    Ganguly, A.; Schneider, A.; Keck, B.; Bennett, N. R.; Fahrig, R.

    2008-03-01

    A high-resolution (198 μm) C-arm CT imaging system (Axiom Artis dTA, Siemens Medical Solutions, Forchheim, Germany) was optimized for imaging superficial femoral artery (SFA) stents in humans. The SFA is susceptible to the development of atherosclerotic lesions. These are typically treated with angioplasty and stent deployment. However, these stents can have a fracture rate as high as 35%. Fracture is usually accompanied by restenosis and reocclusion. The exact cause of breakage is unknown and is hypothesized to result from deforming forces due to hip and knee flexion. Imaging was performed with the leg placed in both straight and bent positions. Projection images obtained during 20 s scans with ~200° of rotation of the C-arm were back-projected to obtain 3D volumes. Using a semi-automatic software algorithm developed in-house, the stent centerlines were found and ellipses were fitted to the slice normals. Image quality was adequate for calculations in 11/13 subjects. Bending the leg was found to shorten the stents in 10/11 cases with the maximum change being 9% (12 mm in a 133 mm stent), and extend the stent in one case by 1.6%. The maximum eccentricity change was 36% with a bend angle of 72° in a case where the stent extended behind the knee.

  7. Massive Bleeding from Guidewire Perforation of an External Iliac Artery: Treatment with Hand-made Stent-Graft Placement

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, Vimal, E-mail: drvimalmehta@yahoo.co.in; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay [G.B. Pant Institute of Postgraduate Medical Education and Research (India)

    2016-01-15

    We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory.

  8. Coronary artery bypass surgery or coronary stenting in diabetic patients: too soon to make a statement?

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Alfredo E., E-mail: arodriguez@centroceci.com.ar

    2014-11-15

    Diabetic patients have been associated with poor procedural and long term outcome if they were treated either with percutaneous coronary interventions or coronary artery bypass surgery. Recently several randomized clinical trials (RCT) in this subset of patients have been published showing a greater incidence of major adverse cardiovascular events, death/myocardial infarction/stroke, if they were treated with first generation drug eluting stents (DES) which was not observed previously in the bare metal stent era. However, almost simultaneously with this data, several RCT demonstrated better safety profile with new generation DES including biocompatible polymers, biodegradable polymers and lately complete absorbable DES, all of them showed reduction in adverse cardiac events compared to 1st generation DES in patients with diabetes. In this editorial we review the old and new randomized data in diabetic patients and conclude that there are many unresolved issues to make a definitive statement regarding which is the best revascularization preference in diabetic patients and the measured final efficacy of PCI and CABG will not be reached until the arrival of RCT using next generation DES, including complete absorbable scaffolds. - Highlights: • Diabetic patients have been associated with poor procedural and long term outcome if they were treated either with percutaneous coronary interventions or coronary artery bypass surgery. Recently several randomized clinical trials (RCT) in this subset of patients have been published showing a greater incidence of major adverse cardiovascular events, death/myocardial infarction/stroke, if they were treated with first generation drug eluting stents (DES) which was not observed previously in the bare metal stent era. • In recent years, several RCT demonstrated better safety profile with new generation DES including biocompatible polymers, biodegradable polymers and lately complete absorbable DES, all of them showed reduction in

  9. COMBINED INTRAOPERATIVE ILIAC ARTERY STENTS AND FEMORO-POPLITEAL BYPASS FOR MULTILEVEL ATHEROSCLEROTIC OCCLUSIVE DISEASE

    Institute of Scientific and Technical Information of China (English)

    刘昌伟; 管珩; 李拥军; 郑曰宏; 刘卫

    2001-01-01

    Objective. To review our preliminary experience and evaluate our early results of a combined intraoperative iliac angioplasty and stenting with infrainguinal revascularization in multilevel atherosclerotic occlusive disease.``Methods. From July 1999 to April 2000, intraoperative iliac angioplasty and stenting combined with simultaneous femoro-popliteal bypass were performed on 12 lower extremities of 10 patients suffering from multilevel atherosclerotic occlusive disease. There were 8 men and 2 women, average 72 years. The indications for procedures included disabling claudication in 3 and rest pain in 7 patients.``Results. Eleven iliac angioplasty and stent procedures combined with simultaneous 9 femoro-popliteal bypass and 3 femoro-femoral-popliteal bypass were performed in 12 limbs of 10 patients. Angioplasty and stent placement was technically successful in all patients. One contralateral femoral-popliteal bypass was failure after femorofemoral-popliteal bypass. There were no additional instances of procedural or postoperative morbidity or mortality. Mean follow-up was 5 months (range 1 ~ 10 months). During the follow-up period, one femoro-infrapoplitealgraft became occluded after 7 months and above-knee amputation was required. The cumulative primary patency rate of stented iliac arteries, femoro-femoral bypass grafts and femoro-popliteal bypass grafts were 100% ( 11 /11), 100% (3/3) and 90. 9% (10/11) in the follow-up period, respectively. The amputation rate was 8.3%(1/12).``Conclusions. Intraoperative iliac artery PTA and stent placement can be safely and effectively performed simultaneously with infrainguinal revascularization for multilevel atherosclerotic occlusive disease by skilled vascular surgeon, using a prtable C arm fluoroscopy in the operating room. Furthermore, iliac artery PTA and stenting was valuable adjunct to distal bypass either to improve inflow and outflow, or to reduce the extent of traditional surgical intervention, and also, any

  10. Coronary Artery Stent Evaluation Using a Vascular Model at 64-Detector Row CT: Comparison between Prospective and Retrospective ECG-Gated Axial Scans

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Shigeru; Furui, Shigeru; Kaminaga, Tatsuro; Miyazawa, Akiyoshi; Ueno, Yasunari; Konno, Kumiko [Teikyo University School of Medicine, Tokyo (Japan); Kuwahara, Sadatoshi; Mehta, Dhruv [Philips Electronics Japan, Ltd. Medical Systems, Tokyo (Japan)

    2009-06-15

    We wanted to evaluate the performance of prospective electrocardiogram (ECG)-gated axial scans for assessing coronary stents as compared with retrospective ECG-gated helical scans. As for a vascular model of the coronary artery, a tube of approximately 2.5-mm inner diameter was adopted and as for stents, three (Bx-Velocity, Express2, and Micro Driver) different kinds of stents were inserted into the tube. Both patent and stenotic models of coronary artery were made by instillating different attenuation (396 vs. 79 Hounsfield unit [HU]) of contrast medium within the tube in tube model. The models were scanned with two types of scan methods with a simulated ECG of 60 beats per minute and using display field of views (FOVs) of 9 and 18 cm. We evaluated the in-stent stenosis visually, and we measured the attenuation values and the diameter of the patent stent lumen. The visualization of the stent lumen of the vascular models was improved with using the prospective ECG-gated axial scans and a 9-cm FOV. The inner diameters of the vascular models were underestimated with mean measurement errors of -1.10 to -1.36 mm. The measurement errors were smaller with using the prospective ECG-gated axial scans (Bx-Velocity and Express2, p < 0.0001; Micro Driver, p = 0.0004) and a 9-cm FOV (all stents: p < 0.0001), as compared with the other conditions, respectively. The luminal attenuation value was overestimated in each condition. For the luminal attenuation measurement, the use of prospective ECG-gated axial scans provided less measurement error compared with the retrospective ECG-gated helical scans (all stents: p < 0.0001), and the use of a 9-cm FOV tended to decrease the measurement error. The visualization of coronary stents is improved by the use of prospective ECG-gated axial scans and using a small FOV with reduced blooming artifacts and increased spatial resolution.

  11. Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

    Energy Technology Data Exchange (ETDEWEB)

    Ichihashi, Shigeo, E-mail: shigeoichihashi@yahoo.co.jp; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko [Nara Medical University, Department of Radiology (Japan)

    2012-12-15

    We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

  12. The use of flow diverter stents in the management of traumatic vertebral artery dissections.

    Science.gov (United States)

    Cohen, José E; Gomori, John M; Moscovici, Samuel; Bala, Miklosh; Itshayek, Eyal

    2013-05-01

    Flow diverters constitute a new generation of flexible self-expanding stent-like devices with a high metal-surface area coverage, specifically designed for the endovascular management of complex cerebral aneurysms. Recently, other potential applications for these devices in the field of occlusive cerebrovascular disease have been described. In vertebral artery dissections causing occlusion associated with a burden of extensive clots, we have found that the reduced porosity of the diverter mesh serves as an effective barrier to in-stent clot protrusion and distal embolization. We describe the novel use of a flow diverter for the management of an occlusive traumatic vertebral artery dissection. Diverter implantation allowed subsequent angioplasty.

  13. Carotid Artery Stenting Successfully Prevents Progressive Stroke Due to Mobile Plaque

    Directory of Open Access Journals (Sweden)

    Masahiro Oomura

    2015-05-01

    Full Text Available We report a case of progressive ischemic stroke due to a mobile plaque, in which carotid artery stenting successfully prevented further infarctions. A 78-year-old man developed acute multiple infarcts in the right hemisphere, and a duplex ultrasound showed a mobile plaque involving the bifurcation of the left common carotid artery. Maximal medical therapy failed to prevent further infarcts, and the number of infarcts increased with his neurological deterioration. Our present case suggests that the deployment of a closed-cell stent is effective to prevent the progression of the ischemic stroke due to the mobile plaque.

  14. Stenting of Variant Left Carotid Artery Using Brachial Artery Approach in a Patient with Unusual Type of Bovine Aortic Arch

    Directory of Open Access Journals (Sweden)

    Emre Gürel

    2016-01-01

    Full Text Available Bovine aortic arch is the most frequently encountered variation in human aortic arch branching. A 63-year-old Asian male presented with symptomatic severe stenosis of left carotid artery originating from the brachiocephalic trunk. Selective engagement to the left carotid artery was unsuccessful using transfemoral approach. We reported on a successful left carotid artery stenting case using right brachial artery approach in a bovine aortic arch. This paper is worthy of reporting in terms of guiding physicians for interventional procedures in these types of challenging cases.

  15. Angioplasty alone versus angioplasty and stenting for subclavian artery stenosis--a systematic review and meta-analysis.

    Science.gov (United States)

    Chatterjee, Saurav; Nerella, Nishant; Chakravarty, Saneka; Shani, Jacob

    2013-01-01

    Subclavian artery stenosis has long been treated with great success with bypass surgery. Percutaneous intervention, often used in combination with stent placement, has come into vogue for the past few years as a safe and effective therapeutic modality. This study aimed to compare angioplasty alone with angioplasty followed by stent placement by combining available data. The objective of this study was to perform a review of the available literature to compare the efficacy of percutaneous transluminal angioplasty (PTA) alone with PTA followed by stent placement for proximal subclavian artery stenosis. Successful recanalization was defined as patency at the end of 1 year, and reocclusions and restenoses were noted as events for the purpose of pooling the data. The authors searched the Specialized Register and the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library, PubMed, EMBASE, and CINAHL databases for relevant trials/studies comparing PTA and PTA with stenting. Review authors independently assessed the methodological quality of studies (focusing on the adequacy of the randomization process, allocation concealment, blinding, completeness of follow-up, and intention-to-treat analysis) and selected studies for inclusion. All retrospective observational studies were also included in the analysis in the absence of double-blinded randomized trials for increasing sample size. All analyses were done using RevMan 5.0. Odds ratio was calculated using Mantel-Haenszel test with a fixed effect model. All included studies were assessed by all authors for potential sources of bias. Eight studies were included in the analysis having 544 participants. Stenting after PTA was significantly superior to angioplasty alone for treatment of subclavian artery stenosis and maintenance of patency at 1 year, as indicated by absence of events (P = 0.004; 95% confidence interval, odds ratio 2.37 [1.32-4.26]) without significant complication rates for either

  16. Transcatheter stenting of arterial duct in duct-dependent congenital heart disease

    Directory of Open Access Journals (Sweden)

    Đukić Milan

    2013-01-01

    Full Text Available Introduction. Critical congenital heart diseases (CHD are mostly duct-dependent and require stable systemic-pulmonary communication. In order to maintain patency of the ductus arteriosus (DA, the first line treatment is Prostaglandin E1 and the second step is the surgical creation of aortic-pulmonary shunt. To reduce surgical risk in neonates with the critical CHD, transcatheter stenting of DA can be performed in selected cases. Case Outline. A four-month old infant was diagnosed with the pulmonary artery atresia with ventricular septal defect (PAA/VSD. The left pulmonary artery was perfused from DA, and the right lung through three major aortopulmonary collaterals (MAPCAs. A coronary stent was placed in the long and critically stenotic DA, with final arterial duct diameter of 3.5 mm, and significantly increased blood supply to the left lung. After the procedure, the infant’s status was improved with regard to arterial oxygen saturation, feeding and weight gain. During the follow-up, one year later, aortography revealed in-stent stenosis. The left pulmonary artery, as well as the branches, was well-developed and the decision was made to proceed with further surgical correction. Conclusion. Stenting of DA can be an effective alternative to primary surgical correction in selected patients with duct-dependent CHD.

  17. Interventional Management of Delayed and Massive Hemobilia due to Arterial Erosion by Metallic Biliary Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hee Seok [Dept. of Radiology, Gyeongsang National University Hospital, Jinju (Korea, Republic of); Shin, Tae Beom [Dept. of Diagnostic Radiology, Kimhae Jung Ang Hospital, Kimhae (Korea, Republic of); Hwang, Jae Cheol [Dept. of Radiology, Ulsan Hospital, Ulsan (Korea, Republic of); Bae, Jae Ik [Dept. of Radiology, Ajou University Hospital, Suwon (Korea, Republic of); Kim, Chang Won [Dept. of Radiology, Busan National University Hospital, Busan (Korea, Republic of)

    2012-01-15

    To evaluate the effectiveness of interventional management for delayed and massive hemobilia secondary to arterial erosion self expandable metallic stent (SES) in with biliary duct malignancy. Over 8-year period, eight patients who suffered from delayed massive hemobilia after SES placement for malignant biliary obstruction as palliative procedure, were included. The mean period between SES placement and presence of massive gastrointestinal hemorrhage was 66.5 days (15-152 days), pancreatic cancer (n = 2), Klatskin tumor (n = 2), common bile duct cancer (n = 2), intrahepatic cholangiocarcinoma (n = 1), and gastric cancer with ductal invasion (n = 1). Angiographic findings were pseudoaneurysm (n = 6), contrast extravasation (n = 1) and arterial spasm at segment (n = 1). Six patients underwent embolization of injured vessels using microcoils and N-butyl cyanoacrylate. Two patients underwent stent graft placement at right hepatic artery to prevent ischemic hepatic damage because of the presence of portal vein occlusion. Massive hemobilia was successfully controlled by the embolization of arteries (n = 6) and stent graft placement (n = 2) without related complications. The delayed massive hemobilia to arterial erosion metallic biliary stent is rare this complication be successfully treated by interventional management.

  18. Stent implantation of left main coronary artery stenosis in an infant: Effective long-term treatment?

    Directory of Open Access Journals (Sweden)

    Christian Paech

    2015-01-01

    Full Text Available Coronary artery stenosis is a rare phenomenon in children. Coronary stent implantation is generally not considered a standard treatment option due to technical difficulties and potential complications in this group of patients. Nevertheless, several pediatric cases reporting successful implantation with acceptable short-term experiences have been described. The following case presents a successful stent implantation for left main coronary artery (LMCA stenosis early after surgery for anomalous left coronary artery from pulmonary artery (ALCAPA at the age of 6 months. The excellent mid-term results and notably the procedure′s potential as a long-term treatment in small children are highlighted. A 6-month-old infant underwent surgery for ALCAPA. Due to sudden postoperative deterioration, cardiac catheterization was performed. Coronary angiography revealed severe (90% ostial LMCA stenosis. A PROMUS drug-eluting stent (Promus Element AL3.0 Χ 8 mm, Boston Scientific, Natick, Massachusetts, USA was implanted. The procedure was performed without complications. Antiplatelet therapy with acetylsalicylic acid and clopidogrel was initiated. Subsequently, cardiac function improved slowly. Cardiac catheterization 3 years 8 months after stent implantation showed no restenosis with a proximal LMCA diameter still at the 50 th percentile for age. Neither were signs of heart failure reported at the last follow-up at 7 years of age. Presupposing normal growth, the implanted stent would thus provide sufficient myocardial perfusion with a LMCA lumen at the 40 th percentile at the age of 16 years. In selected cases, coronary stent implantation may be an effective mid- to long-term treatment of coronary artery stenosis even in very young children.

  19. Stent-based delivery of triptolide reduces neointimal formation in rabbit iliac arteries

    Institute of Scientific and Technical Information of China (English)

    CHEN Ming; WANG Kai-xia; LIU Zhao-ping; HUO Yong

    2005-01-01

    @@ The long-term clinical efficacy of intracoronary stenting is limited by restenosis, which occurs in 15% to 30% of patients.1 In-stent restenosis is solely due to neointimal hyperplasia. Stent-based delivery of sirolimus, which inhibits intimal proliferation by blocking the G1/S transition, has been successfully used to prevent in-stent restenosis in clinical practice. Previous studies have shown that triptolide inhibited the DNA synthesis of vascular smooth muscle cells by blocking the transition from G0/G1 to S phase,2 suggesting that triptolide could be useful for preventing restenosis. The potential unwanted side effects limits the use of systemic administration of this agent for the prevention of in-stent restenosis. Local delivery using a stent platform, however, might allow deposition of a therapeutic triptolide concentration in the arterial wall, with a substantially reduced risk of systemic toxicity. The purpose of the present study was to determine the efficacy of stent-based delivery of triptolide.

  20. Successful management of hepatic artery pseudoaneurysm complicating chronic pancreatitis by stenting

    Institute of Scientific and Technical Information of China (English)

    Cynthia Sudar Singh; Kamini Giri; Renuka Gupta; Mohammed Aladdin; Harinder Sawhney

    2006-01-01

    A 41-year old alchoholic male with a history of chronic pancreatitis was admitted for nausea, vomiting and weight loss. Angiogram was performed and demonstrated an aneurysmal sac with a narrow neck originating from the inferior aspect of the distal portion of the proper hepatic artery. The origin of the pseudoaneurysm was covered with a 5 mm × 2.5 cm Viabahn cover stent (Gore). A repeat angiogram showed some leak and a second stent (6 mm × 2.3 cm)was deployed and overlapped with the first stent by 3 mm. Contrast was injected and a repeat angiogram demonstrated complete exclusion of the aneurysm. A repeat computerized axial tomography (CAT) scan of the abdomen after 24 h showed successful stenting. The patient had an uneventful post-operative course.

  1. Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin

    Energy Technology Data Exchange (ETDEWEB)

    Pecoraro, Felice, E-mail: felicepecoraro@libero.it; Sabatino, Ermanno R.; Dinoto, Ettore; Rosa, Giuliana La; Corte, Giuseppe; Bajardi, Guido [University of Palermo, Vascular Surgery Unit (Italy)

    2015-10-15

    A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conventional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobactam. Patient management consisted of fistula drainage, systemic antibiotic therapy, and daily wound dressing. At 1-month follow-up, the wound was closed. To our knowledge, this is the first case of this type of stent-graft complication presenting with external expulsion.

  2. Drug-eluting stents in superficial femoral artery treatment: could they be the standard of care?

    Science.gov (United States)

    Bosiers, Marc; Deloose, Koen; Callaert, Joren; Peeters, Patrick; Bosiers, Michel

    2016-12-01

    Endovascular techniques have improved markedly over the past several decades. Plain old balloon angioplasty can only reach patencies around 40% after 1 year. Scaffolding stents have resulted in improved short-term results but encountered limitations for longer-term durability. With the introduction of drug-eluting technologies the process of intimal hyperplasia might be slowed, resulting in improved long-term patency results. At first, limus-eluting technologies were not able to transfer the enthusiasm from the coronaries to the infrainguinal vascular bed. However, the newer generation paclitaxel-eluting technologies perform significantly better in femoropopliteal arteries than their non-eluting or non-coated counterparts. The results of a prospective randomized trial comparing DES versus DCB is eagerly awaited. For the moment there seems, based on the meta-analysis, no difference between the two treatment modalities. Although, we need to keep in mind that DCB perform worse in long calcified lesions.

  3. Critical evaluation of stents in the peripheral arterial disease of the superficial femoral artery – focus on the paclitaxel eluting stent

    Directory of Open Access Journals (Sweden)

    Litsky J

    2014-05-01

    Full Text Available Jason Litsky,1 Arijit Chanda,2 Erik Stilp,1 Alexandra Lansky,1 Carlos Mena11Section of Cardiovascular Medicine, Department of Internal Medicine, Yale University School of Medicine, New Haven, CT, USA; 2Section of Cardiology, Department of Internal Medicine, Bridgeport Hospital, Bridgeport, CT, USAAbstract: The endovascular management of obstructive disease of the superficial femoral artery (SFA is challenging due to unique anatomical and biomechanical forces. Obstructive lesions of the SFA make up the largest proportion of lesions leading to symptomatic peripheral arterial disease. Accordingly, endovascular treatment of SFA disease is becoming increasingly common and, in many cases, is the preferred initial therapy. The use of self-expanding nitinol stents have proven superior to percutaneous transluminal balloon angioplasty in the treatment of intermediate length SFA stenosis. However, achieving durable results, as well as attaining adequate therapy for long occlusions typically seen in clinical practice, remains problematic. Newer technologies, such as paclitaxel eluting stents, seem promising in improving outcomes.Keywords: Zilver PTX, self-expanding stent, atherosclerotic disease, superficial femoral artery

  4. One year clinical follow up of paclitaxel eluting stents for acute myocardial infarction compared with sirolimus eluting stents

    NARCIS (Netherlands)

    S.H. Hofma (Sjoerd); M. Valgimigli (Marco); C.A.G. van Mieghem (Carlos); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick); W.J. van der Giessen (Wim); P.P.T. de Jaegere (Peter); E.S. Regar (Eveline); G. Sianos (Georgios); J. Aoki (Jiro); G.A. Rodriguez-Granillo (Gaston); E.P. McFadden (Eugene); A.T.L. Ong (Andrew); R.T. van Domburg (Ron)

    2005-01-01

    textabstractOBJECTIVE: To compare clinical outcome of paclitaxel eluting stents (PES) versus sirolimus eluting stents (SES) for the treatment of acute ST elevation myocardial infarction. DESIGN AND PATIENTS: The first 136 consecutive patients treated exclusively with PES in the setting of primary pe

  5. T-Stenting-and-Small-Protrusion Technique for Bifurcation Stenoses After End-to-Side Anastomosis of Transplant Renal Artery and External Iliac Artery: Report of Two Cases

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yong, E-mail: cheny102@163.com; Ye, Peng, E-mail: thomas19871223@163.com [Southern Medical University, Department of Interventional Radiology, Nanfang Hospital (China); Jiang, Wen-jin, E-mail: 18653501187@163.com [Yantai Yuhuangding Hospital (China); Ma, Shuo-yi, E-mail: mazelong123456789@126.com; Zhao, Jian-bo, E-mail: zhaojianbohgl@163.com; Zeng, Qing-le, E-mail: doctorzengqingle@126.com [Southern Medical University, Department of Interventional Radiology, Nanfang Hospital (China)

    2015-10-15

    Bifurcation stenoses after end-to-side anastomosis of transplant renal artery (TRA) and external iliac artery (EIA), including stenoses at the anastomosis and the iliac artery proximal to the TRA, are rare. In the present article, we report two successfully managed cases of bifurcation stenoses after end-to-side anastomosis of the TRA and EIA using the technique of T-stenting and small protrusion (TAP stenting)

  6. Bioresorbable microporous stents deliver recombinant adenovirus gene transfer vectors to the arterial wall.

    Science.gov (United States)

    Ye, Y W; Landau, C; Willard, J E; Rajasubramanian, G; Moskowitz, A; Aziz, S; Meidell, R S; Eberhart, R C

    1998-01-01

    The use of intravascular stents as an adjunct for percutaneous transluminal revascularization is limited by two principal factors, acute thrombosis and neointimal proliferation, resulting in restenosis. To overcome these limitations, we have investigated the potential of microporous bioresorbable polymer stents formed from poly(L-lactic acid) (PLLA)/poly(epsilon-caprolactone) (PCL) blends to function both to provide mechanical support and as reservoirs for local delivery of therapeutic molecules and particles to the vessel wall. Tubular PLLA/PCL stents were fabricated by the flotation-precipitation method, and helical stents were produced by a casting/winding technique. Hybrid structures in which a tubular sheath is deposited on a helical skeleton were also generated. Using a two-stage solvent swelling technique, polyethylene oxide has been incorporated into these stents to improve hydrophilicity and water uptake, and to facilitate the ability of these devices to function as drug carriers. Stents modified in this manner retain axial and radial mechanical strength sufficient to stabilize the vessel wall against elastic recoil caused by vasoconstrictive and mechanical forces. Because of the potential of direct gene transfer into the vessel wall to ameliorate thrombosis and neointimal proliferation, we have investigated the capacity of these polymer stents to function in the delivery of recombinant adenovirus vectors to the vessel wall. In vitro, virus stock was observed to readily absorb into, and elute from these devices in an infectious form, with suitable kinetics. Successful gene transfer and expression has been demonstrated following implantation of polymer stents impregnated with a recombinant adenovirus carrying a nuclear-localizing betaGal reporter gene into rabbit carotid arteries. These studies suggest that surface-modified polymer stents may ultimately be useful adjunctive devices for both mechanical support and gene transfer during percutaneous

  7. Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, Claus Christian, E-mail: Claus.christian.pieper@ukb.uni-bonn.de; Meyer, Carsten, E-mail: Carsten.Meyer@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany); Rudolph, Jens, E-mail: jens.rudolph@ukb.uni-bonn.de; Verrel, Frauke, E-mail: frauke.verrel@ukb.uni-bonn.de [University of Bonn, Department of Surgery (Germany); Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de; Wilhelm, Kai E., E-mail: kai.wilhelm@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany)

    2013-08-01

    PurposeThis study was designed to evaluate retrospectively the results of complex iliac artery aneurysm (IAA) exclusion using the Cardiatis-Multilayer-Stent.MethodsBetween October 2010 and August 2012, ten IAAs were treated in eight males (mean age 75 (59-91) years) using the Multilayer Stent. All IAA exceeded a diameter of 3 cm or were symptomatic. Follow-up (FU) examinations included CT or MR angiography, sonography, and clinical assessment up to 2 years.ResultsPrimary stent placement was technically successful in eight of ten cases. In two cases, severe stent retraction during deployment necessitated placement of an additional stent. Immediately after stent placement, a marked reduction of flow within the sac was observed in all cases (peri-interventional mortality 0 %). During FU, there were two thrombotic stent occlusions, making reintervention necessary (primary patency rate 80 %, secondary patency 100 %). Four IAA were completely occluded at FU, whereas the original vessel and covered branches (n = 8) were patent. In four IAA, there was still residual perfusion. In one patient, IAA diameter decreased slightly, while it remained constant in seven (mean imaging FU 195 (range 1-695) days). There were no adverse events on clinical FU (mean FU 467 (range 101-695) days).ConclusionsOther studies showed the Cardiatis-Multilayer-Stent to be a technically relatively simple treatment option for complex IAA with inadequate landing zones, especially in patients with multiple comorbidities to avoid ipsilateral IIA obstruction. However, in our series complication rate was high. Incomplete sac exclusion, stent-shortening, and thrombotic occlusion can complicate treatment, making meticulous patient selection necessary. Close imaging surveillance is mandatory especially in the early postinterventional period.

  8. Renal infarction caused by spontaneous renal artery dissection: treatment with catheter-directed thrombolysis and stenting.

    Science.gov (United States)

    Jeon, Yong Sun; Cho, Soon Gu; Hong, Ki Cheon

    2009-03-01

    Spontaneous renal artery dissection (SRAD) is rare and presents a diagnostic and therapeutic challenge. We report a case of a 36-year-old man who had an SRAD-complicated renal infarction. The patient experienced severe unilateral flank pain. Enhanced abdominal computed axial tomography scan showed renal infarction, and urinalysis showed no hematuria. Selective renal angiography was essential to evaluate the extent of dissection and suitability for repair. The patient was treated with catheter-directed thrombolysis and frenal artery stenting.

  9. Stent-grafting combined with transcatheter embolization for a ruptured isolated hypogastric artery aneurysm

    Institute of Scientific and Technical Information of China (English)

    DONG Zhi-hui; FU Wei-guo; GUO Da-qiao; XU Xin; CHEN Bin; JIANG Jun-hao; YANG Jue; SHI Zheng-yu; WANG Yu-qi

    2006-01-01

    @@ Rupture of isolated hypogastric artery aneurysm (HAA) is rarely encountered and is associated with a high mortality rate. Conventional surgery can not achieve distal control easily and may cause substantial blood loss, yielding high operative morbidity and mortality. On March 17, 2005, we treated a patient with such a disease successfully by using endovascular stent-grafting combined with transcatheter embolization.

  10. Valve-Like and Protruding Calcified Intimal Flap Complicating Common Iliac Arteries Kissing Stenting

    Directory of Open Access Journals (Sweden)

    George S. Georgiadis

    2015-01-01

    Full Text Available Endovascular therapy for iliac artery chronic total occlusions is nowadays associated with low rates of procedure-related complications and improved clinical outcomes, and it is predominantly used as first-line therapy prior to aortobifemoral bypass grafting. Herein, we describe the case of a patient presenting with an ischemic left foot digit ulcer and suffering complex aortoiliac lesions, who received common iliac arteries kissing stents, illustrating at final antegrade and retrograde angiograms the early recognition of a blood flow obstructing valve-like calcified intimal flap protruding through the stent struts, which was obstructing antegrade but not retrograde unilateral iliac arterial axis blood flow. The problem was resolved by reconstructing the aortic bifurcation at a more proximal level. Completion angiogram verified normal patency of aorta and iliac vessels. Additionally, a severe left femoral bifurcation stenosis was also corrected by endarterectomy-arterioplasty with a bovine patch. Postintervention ankle brachial pressure indices were significantly improved. At the 6-month and 2-year follow-up, normal peripheral pulses were still reported without intermittent claudication suggesting the durability of the procedure. Through stent-protruding calcified intimal flap, is a very rare, but existing source of antegrade blood flow obstruction after common iliac arteries kissing stents.

  11. Stenting of unprotected left main coronary artery in a patient with cardiogenic shock

    Directory of Open Access Journals (Sweden)

    Bedson José Lopes de Sá

    1999-09-01

    Full Text Available A 64-year-old female presented with pulmonary edema and cardiogenic shock after coronary arteriography that showed severe suboclusive lesion in the left main coronary artery (LMCA in a dominant left coronary system. The patient succesfully underwent urgent angioplasty with stent deployment in the LMCA. After an uneventful period, the patient was discharged at day six.

  12. Telescoping dual covered stent graft construct for endovascular treatment of a giant extracranial carotid artery pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Dale Ding

    2016-01-01

    Full Text Available Large pseudoaneurysms which compress the parent vessel are challenging lesions to successfully treat with endovascular therapy. We describe the endovascular treatment of a giant extracranial carotid artery (ECCA pseudoaneurysm resulting in substantial mass effect on the common carotid artery (CCA bifurcation using a telescoping dual covered stent graft construct. A 56-year-old male was diagnosed with an 8.5 cm × 13 cm pseudoaneurysm arising from the left CCA bifurcation, which was causing luminal narrowing of the CCA and proximal internal carotid artery (ICA. The patient underwent endovascular intervention, during which a balloon-expandable covered stent was deployed within a heparin-bonded covered stent, such that the overall construct spanned from the CCA to the lower cervical ICA. The employment of a telescoping dual covered stent technique can successfully treat appropriately selected patients with large or giant ECCA pseudoaneurysms, with the concomitant goals of excluding the pseudoaneurysm and restoring the luminal caliber of the parent artery.

  13. Selection of treatment for patients with carotid artery disease: medication, carotid endarterectomy, or carotid artery stenting.

    Science.gov (United States)

    Bosiers, Marc; Peeters, Patrick; Deloose, Koen; Verbist, Jürgen; Sprouse, Richard L

    2005-01-01

    Patients presenting with atherosclerosis of the extracranial carotid arteries may be offered carotid endarterectomy (CEA), carotid artery stenting (CAS), or medical therapy to reduce their risk of stroke. In many cases, the choice between treatment modalities remains controversial. An algorithm based on patients' neurologic symptoms, comorbidities, limiting factors for CAS and CEA, and personal preferences was developed to determine the optimal treatment in each case. This algorithm was then employed to determine therapy in 308 consecutive patients presenting to a single institution during one calendar year. Ninety-five (30.8%) patients presented with an asymptomatic carotid stenosis of more than 80% and 213 (69.2%) with a symptomatic stenosis of more than 50%. According to our algorithm, 59 (62.1%) of the 95 asymptomatic patients received CAS, 20 (21.1%) received CEA, and 16 (16.8%) received medical therapy. All symptomatic patients underwent intervention; 153 (71.8%) were treated with CAS and 60 (28.2%) with CEA. Combined 30-day stroke and death rates after CAS were 1.7% in asymptomatic patients and 2.6% in symptomatic patients. After CEA, these rates were 0% and 3.3%, respectively. Careful selection of treatment modality according to predetermined criteria can result in improved outcomes.

  14. ISR II study: a long-term evaluation of sirolimus-eluting stent in the treatment of patients with in-stent restenotic native coronary artery lesions.

    Science.gov (United States)

    Commeau, Philippe; Barragan, Paul T; Roquebert, Pierre O; Siméoni, Jean B

    2005-10-01

    The aim of this pilot study was to determine the safety and long-term efficacy of treating intrastent restenosis (ISR) with the slow-release sirolimus-eluting stent Bx Velocity (Cypher stent) without intravascular ultrasound (IVUS) guidance. Of patients who received a bare metal stent implantation and presented an ISR, 30-80% of the patients will develop a second restenosis within the stent, at the stent edges or both. To date, intravascular brachytherapy using beta- and gamma-radiation has been the only effective treatment for ISR. Twenty-three patients with ISR and evidence of ischemia were treated with Cypher stent. Clinical information was collected 1, 8, 12, and 24 months after stent implantation. During the first 8 months of the study, in-stent lumen diameter remained essentially unchanged from postprocedure in 80% of the case. The target lesion repeat revascularization (TLR) was 17%, of which 50% were oculostenotic reflexes. Only one patient presented a restenosis greater than 70%. During the 2-year study period, the TLR rate was 17%; the major adverse coronary event rate was 26%, and the non-Q-wave myocardial infarction (MI) rate was 9%. There were no reports of death, coronary artery bypass grafting, or Q-wave MI during the study. This study demonstrates the feasibility of using sirolimus-eluting stents without IVUS guidance for the treatment of ISR, providing long-term stability of immediate results.

  15. [Subclavian artery stenting using gadolinium contrast medium in a case with iodine allergy].

    Science.gov (United States)

    Miyamoto, Michiyuki; Asano, Takeshi; Osanai, Toshiya; Endo, Shogo; Nakayama, Naoki; Kuroda, Satoshi; Houkin, Kiyohiro

    2012-05-01

    The authors reported a subclavian artery stenting (SAS) using gadolinium contrast medium. The patient was a 65-year-old female who presented dizziness and right upper extremity pain with movement. Digital subtraction angiography revealed right subclavian artery occlusion with subclavian steal phenomenon. We tried to treat this lesion using SAS. However, iodinated contrast medium caused the allergy in this patient and the treatment was discontinued. Therefore, SAS was performed with gadolinium contrast medium. Using gadolinium contrast medium, it is possible to confirm large arteries like innominate artery and subclavian artery. The stenting procedure was performed without complication. The usage of gadolinium contrast medium has the limit and some strategies are important to reduce the usage of gadolinium contrast medium in SAS. First, PercuSurge GuardWire® was placed in the right internal carotid artery to confirm the anatomy, to decide working angle, and to treat the common carotid artery in case of dissection. Second, a "U" shaped guide wire was placed in the distal end from the brachial artery. Guide wire from femoral side was able to pass the lesion at midpoint of the "U" shaped one. SAS using gadolinium contrast medium may be an alternative treatment if a patient with subclavian artery stenosis or occlusion is allergic to iodinated contrast medium.

  16. Recent trends on the stent research for blood arteries by bibliometric analysis.

    Science.gov (United States)

    Ahn, Sejung; Sung, Jung-Suk; Choi, Brad; Kim, Hackjoo; Sung, Yong Kiel

    2014-01-01

    The research trends on stent for blood arteries are reviewed by bibliometric analysis using 7,790 journal articles published from 1986 to 2013 of the Web of Science database. The bibliometric indicators are applied to analyze the journal article data, which are simple number of publications for selecting key players, citation indicators for measuring qualitative research performance, collaboration indicators for figuring out the degree of international collaboration and keyword mapping for identifying the research trends. The studies of stent for blood arteries are investigated on the basis of the analysis by countries, institutions and topic changing. The leading countries and institutions published many high-quality journal articles with strong international collaboration. In this report, the current status and future of research trends are clearly revealed from the periodic topic changing analysis. The keywords such as 'drug eluting stent', 'stent coated with new polymers' and 'drug delivery systems' have come into the recent stent-related research, which means lots of efforts are under way to overcome the present limitations of the research.

  17. Mechanical Interaction of an Expanding Coiled Stent with a Plaque-Containing Arterial Wall: A Finite Element Analysis.

    Science.gov (United States)

    Welch, Tré R; Eberhart, Robert C; Banerjee, Subhash; Chuong, Cheng-Jen

    2016-03-01

    Wall injury is observed during stent expansion within atherosclerotic arteries, related in part to stimulation of the inflammatory process. Wall stress and strain induced by stent expansion can be closely examined by finite element analysis (FEA), thus shedding light on procedure-induced sources of inflammation. The purpose of this work was to use FEA to examine the interaction of a coiled polymer stent with a plaque-containing arterial wall during stent expansion. An asymmetric fibrotic plaque-containing arterial wall model was created from intravascular ultrasound (IVUS) images of a diseased artery. A 3D model for a coil stent at unexpanded state was generated in SolidWorks. They were imported into ANSYS for FEA of combined stent expansion and fibrotic plaque-distortion. We simulated the stent expansion in the plaqued lumen by increasing balloon pressure from 0 to 12 atm in 1 atm step. At increasing pressure, we examined how the expanding stent exerts forces on the fibrotic plaque and vascular wall components, and how the latter collectively resist and balance the expansive forces from the stent. Results show the expanding coiled stent creates high stresses within the plaque and the surrounding fibrotic capsule. Lower stresses were observed in adjacent medial and adventitial layers. High principal strains were observed in plaque and fibrotic capsule. The results suggest fibrotic capsule rupture might occur at localized regions. The FEA/IVUS method can be adapted for routine examination of the effects of the expansion of selected furled stents against IVUS-reconstructed diseased vessels, to improve stent deployment practices.

  18. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  19. Endovascular stent graft for treatment of complicated spontaneous dissection of celiac artery: Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Diagnostic Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Hwan [Dept. of Diagnostic Radiology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2013-06-15

    We report 2 cases of complicated spontaneous dissection of the celiac artery, which were successfully treated by a stent graft. The first patient was a 47-year-old man who presented with acute abdominal pain. CT scan showed ruptured saccular aneurysm with surrounding retroperitoneal hematoma. The second patient was a 57-year-old man with progressive dissecting aneurysm. Endovascular stent graft was placed in the celiac trunk to control bleeding, and to prevent rupture in each patient. Follow-up CT scans showed complete obliteration of a dissecting aneurysm.

  20. Percutaneous transluminal angioplasty and stenting of the vertebral artery ostium with balloon-mounted bare coronary stents

    Directory of Open Access Journals (Sweden)

    Javad Kojuri

    2011-01-01

    Full Text Available Background : Vertebral artery ostial stenosis (VAOS is one of the most frequent causes of posterior circulation stroke. Percutaneous angioplasty and stenting (PTAS is one of the treatment modalities. Patients and Methods : This is a longitudinal observational study from September 2006 to February 2009, conducted at hospitals affiliated with the Shiraz University of Medical Sciences, Shiraz, southern Iran. The patient cohort included patients with posterior circulation stroke or transient ischemic attack (TIA and more than 70% VAOS, and patients with asymptomatic VAOS of more than 70% and aplasia or total occlusion of the contralateral VA or subclavian artery. All the patients underwent PTAS with balloon-mounted bare coronary stents. Technical success, procedural complications, composite outcomes of death, stroke or TIA in the vertebrobasilar territory during the first 30 days, stroke or TIA in the vertebrobasilar territory, and restenosis during follow-up, were assessed. Results : During the study period, 81 patients (mean age 68 + 8.9 years, 63 (78% males, 71 symptomatic and 18 asymptomatic underwent the procedure. Technical success was achieved in 88 (99% patients. Procedure-related complications, other than puncture site complications, were seen in two patients (2.2%. The composite outcome of death, stroke or TIA in the vertebrobasilar territory during the first 30 days was 1%. None of the patients had clinical recurrence or restenosis during the follow-up (mean follow-up 14 months. Conclusion : Percutaneous transluminal angioplasty and stenting of the proximal VA was feasible and safe. The risk of restenosis should be analyzed in long-term studies with angiographic follow-up.

  1. Stenting for symptomatic vertebral artery stenosis associated with bilateral carotid rate mirabile: The long-term clinical and angiographic outcome

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jang Hyun; Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    Symptomatic vertebral artery (VA) stenosis associated with bilateral carotid rate mirabile (CRM) has not been reported. We report the long-term clinical and angiographic outcome after stenting for symptomatic VA stenosis in the patient with bilateral CRM. This report is the first case that symptomatic VA stenosis associated with bilateral CRM was treated with stenting.

  2. The role of superficial femoral artery endoluminal bypass in long de novo lesions and in-stent restenosis.

    NARCIS (Netherlands)

    Doomernik, D.E.; Golchehr, B.; Lensvelt, M.M.A.; Reijnen, M.M.P.J.

    2012-01-01

    AIM: Results of endovascular treatment for long de novo lesions of the superficial femoral artery (SFA) are limited by in-stent restenosis (ISR). Polytetrafluoroethylene (PTFE) covered stents are developed to reduce the incidence of ISR. This study was conducted to summarize available data on the us

  3. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter); F. Kiemeneij (Ferdinand); C.M. Miguel (Carlos); W.R. Rutsch (Wolfgang); G.R. Heyndrickx (Guy); H.U. Emanuelsson (Hakan); J. Marco (Jean); V.M.G. Legrand (Victor); P.H. Materne (Phillipe); J.A. Belardi (Jorge); U. Sigwart (Ulrich); A. Colombo (Antonio); J-J. Goy (Jean-Jacques); P.A. van den Heuvel (Paul); J. Delcan; M-A.M. Morel (Marie-Angèle)

    1994-01-01

    textabstractBalloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as c

  4. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease.

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter); F. Kiemeneij (Ferdinand); C.M. Miguel (Carlos); W.R. Rutsch (Wolfgang); G.R. Heyndrickx (Guy); H.U. Emanuelsson (Hakan); J. Marco (Jean); V.M.G. Legrand (Victor); P.H. Materne (Phillipe); J.A. Belardi (Jorge); U. Sigwart (Ulrich); A. Colombo (Antonio); J-J. Goy (Jean-Jacques); P. van den Heuvel; J. Delcan; M-A.M. Morel (Marie-Angèle)

    1994-01-01

    textabstractBACKGROUND. Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical o

  5. Subclavian artery stenosis caused by non-specific arteritis (Takayasu disease): treatment with Palmaz stent

    Energy Technology Data Exchange (ETDEWEB)

    Maskovic, J.; Jankovic, S.; Lusic, I.; Cambj-Sapunar, L.; Mimica, Z.; Bacic, A

    1999-09-01

    A 32-year old woman was admitted to the hospital with a sudden onset of right-sided hemiplegia and aphasia. Immediate angiographic examination revealed a severe form of type I Takayasu arteritis with occlusion of all supra-aortic vessels, with the exception of the left subclavian artery which was, however, almost completely occluded 1 cm proximal to the origin of the left vertebral artery. Since the latter provided the entire blood supply to the brain tissues, an immediate attempt was undertaken to dilate the left subclavian artery; when this was unrewarding, stenting of the lesion was successfully accomplished with excellent primary and 6-month follow-up results.

  6. Balloon Tamponade Treatment of a Stent-graft Related Rupture with a Splenic Artery Pseudoaneurysm: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, See Hyung; Kim, Young Hwan [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stentgraft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency

  7. Successful percutaneous transluminal angioplasty and stenting for symptomatic intracranial vertebral artery stenosis using intravascular ultrasound virtual histology.

    Science.gov (United States)

    Takayama, Katsutoshi; Taoka, Toshiaki; Nakagawa, Hiroyuki; Myouchin, Kaoru; Wada, Takeshi; Sakamoto, Masahiko; Fukusumi, Akio; Iwasaki, Satoru; Kurokawa, Shinichiro; Kichikawa, Kimihiko

    2007-06-01

    This is the first report of percutaneous transluminal angioplasty (PTA) of an intracranial artery applying intravascular ultrasound virtual histology (IVUS-VH), which has been recently developed for tissue characterization of coronary artery plaque. We report a case of successful PTA and stenting for symptomatic intracranial vertebral artery stenosis using IVUS-VH.

  8. Changes in regional cerebral hemodynamics and its significance after internal carotid artery stenting in patients with moderate/severe internal carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Jia-chuan YAN

    2011-08-01

    Full Text Available Objective To evaluate the cerebral hemodynamic changes before and after carotid artery angioplasty and stenting.Methods Thirty-eight patients with moderate/severe internal carotid artery stenosis underwent carotid artery angioplasty and stenting.CT perfusion imaging was performed pre-and post-surgery to determine the cerebral blood flow(CBF,cerebral blood volume(CBV and mean transit time(MTT in the ipsilateral and contralateral cerebrum.Results Before angioplasty and stenting,the CBF and CBV decreased,and MTT increased in the ipsilateral cerebrum than in contralateral cerebrum.After intervention,the CBF and CBV increased and CTT shortened obviously in comparison with that of pre-surgery(P 0.05.Conclusion Angioplasty and stenting may improve the cerebral hemodynamics of patients with severe/moderate internal carotid artery stenosis.

  9. Uretero-Internal Pudendal Artery Fistula with Longterm Indwelling of Ureteral Stent: A Case Report

    Directory of Open Access Journals (Sweden)

    Hideo Yuki

    2012-01-01

    Full Text Available A 74-year-old woman presenting with bilateral ureteral stricture was referred to our hospital. She had undergone radical hysterectomy and adjuvant irradiation therapy for cervical cancer in 2000. Double-J stents were inserted in both the ureters and replaced at regular intervals. Eighteen months after ureteral stenting, she complained of gross hematuria and was managed with hemostatic agents. During a routine replacement of the right double-J stent, massive bleeding was observed from the urethra which continued intermittently. The source of bleeding was not identified on computed tomography and angiography. We kept her at rest, which reduced the bleeding. However, she required intermittent transfusions. Angiography was performed at the time of bleeding on March 5, 2011. A uretero-internal pudendal artery fistula was found, and coil embolization was performed. Thereafter, hematuria did not recur up to the last followup in July 2011.

  10. Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito [Kainan Hospital Aichi Prefectural Welfare Federation of Agricultural Cooperatives, Department of Neurosurgery, Aichi (Japan); Miyachi, Shigeru; Hattori, Kenichi [Nagoya University Graduate School of Medicine, Department of Neurosurgery, Nagoya (Japan)

    2006-11-15

    Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)

  11. Accidental Coverage of Both Renal Arteries during Infrarenal Aortic Stent-Graft Implantation: Cause and Treatment

    Directory of Open Access Journals (Sweden)

    Umberto Marcello Bracale

    2014-01-01

    Full Text Available The purpose of this paper is to report a salvage maneuver for accidental coverage of both renal arteries during endovascular aneurysm repair (EVAR of an infrarenal abdominal aortic aneurysm (AAA. A 72-year-old female with a 6 cm infrarenal abdominal aortic aneurysm was treated by endovascular means with a standard bifurcated graft. Upon completing an angiogram, both renal arteries were found to be accidentally occluded. Through a left percutaneous brachial approach, the right renal artery was catheterized and a chimney stent was deployed; however this was not possible for the left renal artery. A retroperitoneal surgical approach was therefore carried out with a retrograde chimney stent implanted to restore blood flow. After three months, both renal arteries were patent and renal function was not different from the baseline. Both endovascular with percutaneous access via the brachial artery and open retroperitoneal approaches with retrograde catheterization are feasible rescue techniques to recanalize the accidentally occluded renal arteries during EVAR.

  12. Safety and Feasibility of Simultaneous Ipsilateral Proximal Carotid Artery Stenting and Cerebral Aneurysm Coiling

    Directory of Open Access Journals (Sweden)

    Aamir Badruddin

    2010-10-01

    Full Text Available Background: Coexistence of cerebral aneurysm and carotid artery disease may be encountered in clinical practice. Theoretical increase in aneurysmal blood flow may increase risk of rupture if carotid artery disease is treated first. If aneurysm coiling is performed first, stroke risk may increase while repeatedly crossing the diseased artery. It is controversial which disease to treat first, and whether it is safe to treat both simultaneously via endovascular procedures. We document the safety and feasibility of such an approach. Methods: Review of collected neurointerventional database at our institution was performed for patients who underwent both Carotid artery stenting (CAS and aneurysm coil embolization (ACE simultaneously. All patients underwent carotid stenting followed by aneurysm coiling in the same setting. Demographic, clinical data and outcome measures including success rate and periprocedural complications were collected. Results: 590 aneurysms coiling were screened for patients who underwent combined CAS and ACE. Ten patients were identified. Mean age was 67.7 years (range 51 to 89. The success rate for stenting and coiling was 100% with no immediate complications. No stroke, TIAs, or aneurysmal rebleeding was found on their most recent follow up. Conclusions: Our case series demonstrates that it is safe and feasible to perform CAS and ACE simultaneously as one procedure which may avoid unwanted risk of treating either disease at two separate time sessions.

  13. One-year clinical outcomes of Chinese sirolimus-eluting stent in the treatment of unselected patients with coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ The application of drug-eluting stent (DES), either sirolimus-eluting stent (Cypher, Cordis, USA) or paclitaxel-eluting stent (Taxus, Boston Scientific, USA), in treatment of patients with coronary artery disease (CAD) has achieved great success.1-4 The high cost of imported DES (either Cypher or Taxus) gave the birth to a China-made, polymer-based, sirolimus-eluting stent (Firebird, Microport Company, China). In March 2003, China Food and Drug Administration approved the clinical use of Firebird stent. However, the safety and efficacy of Firebird stent in comparison with Cypher and Taxus stents are still underestimated.

  14. Improved anticoagulation management after Palmaz Schatz coronary stent implantation by sealing the arterial puncture site with a vascular hemostasis device.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J

    1993-12-01

    Sealing the arterial puncture site with a vascular hemostasis device has the potential to maintain optimal anticoagulation after stent implantation. The level of heparinization during the first 3 days after successful stent implantation was retrospectively compared between 2 groups of medically treated patients with (group A; n = 18) and without (group B; n = 17) a Vasoseal after sheath removal. The number of APTTs sampled in group A and B was 233 and 168, respectively. Respective mean values of APTT (seconds) in group A and B were 180 +/- 79 and 172 +/- 91 at day 1 (p = NS), 132 +/- 43 and 125 +/- 61 at day 2 (p = NS) and 123 +/- 36 and 116 +/- 48 at day 3 (p = NS). More APTTs were suboptimal (< 80 secs) in group B (34/168; 20%) compared to group A (17/233; 7%) [p < 0.001]. More patients in group B compared to group A had 1 or more (14/17; 82% vs. 8/18; 44%; p = 0.04), 2 or more (10/17; 59% versus 3/18; 17%; p = 0.02) and 3 or more (8/17; 47% vs. 2/18; 11%; p = 0.03) suboptimal APTTs. Bleeding complications were seen in 4 patients without and in 3 patients with a Vasoseal. Thus application of a vascular hemostasis device results in a less variable anticoagulation after coronary stenting, but it does not abolish entry site-related bleeding complications.

  15. Optimal scanning protocols of 64-slice CT angiography in coronary artery stents: An in vitro phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Almutairi, Abdulrahman Marzouq [Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, Perth, Western Australia (Australia); Sun Zhonghua [Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, Perth, Western Australia (Australia)], E-mail: z.sun@curtin.edu.au; Ng, Curtise [Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, Perth, Western Australia (Australia); Al-Safran, Zakariya A.; Al-Mulla, Abeer A.; Al-Jamaan, Abdulaziz I. [Department of Medical Imaging, King Fahad Specialist Hospital, Dammam (Saudi Arabia)

    2010-04-15

    Purpose: The purpose of the study was to investigate the optimal scanning protocol of 64-slice CT angiography for assessment of coronary artery stents based on a phantom study. Materials and methods: Coronary stents with a diameter of 2.5 mm was implanted in thin plastic tubes with an inner diameter of 3.0 mm to simulate a coronary artery. The tubes were filled with iodinated contrast medium diluted to 178 HU, closed at both ends and positioned in a plastic container filled with vegetable oil (-70 to -100 HU). A series of scans were performed with a 64-slice CT scanner with the following protocols: section thickness: 0.67 mm, 1.0 mm, 1.5 mm, 2.0 mm, pitch value: 0.2, 0.3, 0.5 and reconstruction interval of 50% overlap of the section thickness. 2D axial and multiplanar reformatted images were generated to assess the visibility of stent lumen, while virtual intravascular endoscopy (VIE) was reconstructed to evaluate the artery wall and stent surface. Results: Our results showed that a scanning protocol of 1.0 mm slice thickness with a pitch of 0.3 produced acceptable images with best demonstration of the intrastent lumen and stent surface with minimal image noise or artifacts. In contrast, submillimeter scans with 0.67 mm resulted in moderate artifacts which affected visualization of the coronary lumen, in addition to the increased noise. When the section thickness increased to 1.5 mm and 2.0 mm, visualization of the artery wall and stent surface was compromised, although the intrastent lumen was still visible. Conclusion: Our in vitro study suggested that a scanning protocol of 1.0 mm section thickness with pitch of 0.3 is the optimal protocol for evaluation of coronary artery stents as it allows generation of acceptable images with better visualization of stent lumen, stent surface and coronary artery wall.

  16. Prognosis of unprotected left main coronary artery stenting and the factors affecting the outcomes in Chinese

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background The long term prognosis of unprotected left main coronary artery (LMCA) stenting is controversial This study was conducted to evaluate the immediate and long term outcomes of LMCA stenting in Chinese patients and to determine which factors affect the outcomes. Methods From May 1997 to March 2003,224 patients in 23 hospitals underwent elective unprotected LMCA stenting with bare metal stents. Their clinical records were analysed to ascertain immediate and long term outcomes of LMCA stenting as well as factors influencing the prognosis .Results Stents were implanted into LMCA successfully in 223 cases (99.6 %). One death (0.5%) and one case of non-Q wave nonfatal myocardial infarction (MI) occurred in hospital. The mean follow-up time was (15.6±12.3) months. Cardiac death developed in 10 cases (4.5%), noncardiac death in 2 cases (0.9%), nonfatal MI in 4 cases (1.8%), target lesion revascularization (TLR) of LMCA in 26 cases (11.7%) and TLR of nonLMCA in 37 cases (16.5%). Univariate analysis showed that cardiac death correlated with left ventricular ejection fraction (LVEF < 40%), female gender and LMCA combined with multivessel disease; that major adverse cardiac events (MACE) correlated with LVEF < 40%, bifurcation lesion and incomplete revascularization. Logistic regression analysis revealed that LVEF < 40% and female gender were independent predictors of cardiac death and MACE. Follow-up angiography was performed in 102 cases (45.7%). The restenosis rate was 31.4%. Conclusions Long-term outcomes of stenting for selected patients with unprotected LMCA stenosis is acceptable. It should be performed in inoperable or low risk patients with LVEF ≥ 40% and isolated LMCA disease or LMCA combined with multivessel diseases in whom complete revascularization can be obtained.

  17. Recent concepts in the management of extracranial carotid stenosis: Carotid endarterectomy versus carotid artery stenting

    Directory of Open Access Journals (Sweden)

    Jeyaraj D Pandian

    2011-01-01

    Full Text Available Carotid stenosis is seen in 10% of patients with ischemic stroke, and carotid endarterectomy (CEA and carotid artery stenting (CAS are the two invasive treatments options available. Pooled analysis of the three largest randomized trials of CEA involving more than 3000 symptomatic patients estimated 30-day stroke and death rate at 7.1% after CEA. Some subgroups among the symptomatic patients appeared to have more benefit from CEA. These include patients aged 75 years or more, patients with ulcerated plaques, and patients with recent transient ischemic attacks within 2 weeks of randomization. Selection of asymptomatic patients for carotid revascularization should be guided by an assessment of comorbid conditions, life expectancy, and other individual factors, and should include a thorough discussion of the risks and benefits of the procedure with an understanding of patient preferences. The recent trials comparing CEA with CAS has not established its superiority over CEA. The carotid revascularization endarterectomy versus stenting (CREST study showed that CAS is still associated with a higher periprocedural risk of stroke or death than CEA. In patients over 70 years of age, CEA is clearly superior to CAS. The increased risk of nonfatal myocardial infarction in the CREST group subjected to CEA clearly suggests that patients being considered for CEA or CAS require a careful preliminary cardiac evaluation. CAS can be justified for patients whose medical comorbidities or cervical anatomy make them questionable candidates for CEA. The benefit of revascularization by either method versus modern aggressive medical therapy has not been established for patients with asymptomatic carotid stenosis.

  18. Thirty-day outcome of carotid artery stenting in Chinese patients: a single-center experience

    Institute of Scientific and Technical Information of China (English)

    JIAO Li-qun; SONG Gang; LI Shen-mao; MIAO Zhong-rong; ZHU Feng-shui; JI Xun-ming; YIN Guo-yang

    2013-01-01

    Background Carotid artery stenting (CAS) as a competing treatment modality has had to adhere to limits to gain widespread acceptance in some studies.This study analyzed the clinical data of 1700 consecutive patients after CAS to retrospectively evaluate the 30-day outcome of CAS for internal carotid artery stenosis in a Chinese population.Methods Medical records of 1700 patients who underwent CAS at Xuanwu Hospital affiliated to Capital Medical University between January 2001 and August 2012 were reviewed.Postoperative 30-day complication rates were analyzed and compared with those of other studies.Univariate and multivariate Logistic regression analyses were used to identify factors associated with perioperation myocardial infarction (MI),stroke,and death.Results The overall 30-day rate of MI,stroke,and death after CAS was 2.53%.In univariate analysis,patients who were symptomatic,had a neurological deficit (modified Rankin score (mRS) ≥3; P=0.001),and who were not taking statins experienced a significantly increased rate of MI,stroke,and death (P=-0.017).In multivariate Logistic regression analysis,the presence of symptoms (odds ratio (OR)=2.485; 95% confidence interval (CI)=1.267-4.876; P=0.008) and a neurological deficit (mRS ≥3) (OR=3.025; 95% CI=1.353-6.763; P=0.007) were independent risk factors for perioperative MI,stroke,and death.Conclusions According to this single-center experience,CAS may effectively prevent and treat carotid artery stenosis that would otherwise lead to stroke.Being symptomatic and having a neurological deficit (mRS ≥3) increased the risk of perioperative MI,stroke,and death.

  19. Stent placement for chronic iliac arterial occlusive disease: the results of 10 years experience in a single institution

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kwang Bo; Do, Young Soo; Kim, Dong Ik; Kim, Duk Kyung; Kim, Young Wook; Shin, Sung Wook; Cho, Sung Ki; Choo, Sung Wook; Choe, Yeon Heyon; Choo, In Wook [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Jae Hyung; Han, Yoon Hee [Inje Univ., Kimhae (Korea, Republic of)

    2005-12-15

    We wanted to retrospectively evaluate the long-term therapeutic results of iliac arterial stent placement that was done in a single institution for 10 years. From May 1994 to April 2004, 206 patients who underwent iliac arterial stent placement (mean age; 64 {+-} 8.8) were followed up for evaluating the long term stent patency. Combined or subsequent bypass surgery was performed in 72 patients. The follow up period ranged from one month to 120 months (mean; 31 {+-} 25.2 months). The factors that were analyzed for their effect on the patency of stents were age, the stent type and diameter, the lesion site, lesion shape, lesion length, the Society of Cardiovascular and Interventinal Radiology criteria, the total run off scores, the Fontaine stage and the cardiovascular risk factors (diabetes mellitus, hypertension and smoking). Follow-up included angiography and/or CT angiography, color Doppler sonography and clinical evaluation with the ankle-brachial index. Two hundred and eighty-four stents were placed in 249 limbs of 203 patients. The technical success rate was 98% (203/206). The primary patency rates of the stents at 3, 5, 7 and 10 year were 87%, 83%, 61% and 49%, respectively. One hundred seventy-seven patients maintained the primary stent patency until the final follow up and 26 patients showed stenosis or obstruction during the follow up. Secondary intervention was performed in thirteen patients. Lesions in the external iliac artery (EIA) or lesions in both the common iliac artery (CIA) and EIA were a poor prognostic factor for stent patency. The run off score and stent diameter also showed statistically significant influence on stent patency. The overall complication rate was 6%. Iliac arterial stent placement is a safe treatment with favorable long term patency. Lesions in the EIA or lesions in both the EIA and CIA, poor run off vessels and a stent having the same or a larger diameter than 10 mm were the poor prognostic factors for long term stent patency.

  20. Nine-month Angiographic and Two-year Clinical Follow-up of Novel Biodegradable-polymer Arsenic Trioxide-eluting Stent Versus Durable-polymer Sirolimus-eluting Stent For Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Li Shen

    2015-01-01

    Full Text Available Background: Despite great reduction of in-stent restenosis, first-generation drug-eluting stents (DESs have increased the risk of late stent thrombosis due to delayed endothelialization. Arsenic trioxide, a natural substance that could inhibit cell proliferation and induce cell apoptosis, seems to be a promising surrogate of sirolimus to improve DES performance. This randomized controlled trial was to evaluate the efficacy and safety of a novel arsenic trioxide-eluting stent (AES, compared with traditional sirolimus-eluting stent (SES. Methods: Patients with symptoms of angina pectoris were enrolled and randomized to AES or SES group. The primary endpoint was target vessel failure (TVF, and the second endpoint includes rates of all-cause death, cardiac death or myocardial infarction, target lesion revascularization (TLR by telephone visit and late luminal loss (LLL at 9-month by angiographic follow-up. Results: From July 2007 to 2009, 212 patients were enrolled and randomized 1:1 to receive either AES or SES. At 2 years of follow-up, TVF rate was similar between AES and SES group (6.67% vs. 5.83%, P = 0.980. Frequency of all-cause death was significantly lower in AES group (0 vs. 4.85%, P = 0.028. There was no significant difference between AES and SES in frequency of TLR and in-stent restenosis, but greater in-stent LLL was observed for AES group (0.29 ± 0.52 mm vs. 0.10 ± 0.25 mm, P = 0.008. Conclusions: After 2 years of follow-up, AES demonstrated comparable efficacy and safety to SES for the treatment of de novo coronary artery lesions.

  1. Endovascular therapy for abdominal aortic aneurysm and iliac artery aneurysm using SEAL aortic stent-graft: A single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Park, Su Young; Kim, Jeong Ho; Byun, Sung Su; Kang, Jin Mo; Choi, Sang Tae; Park, Jae Hyung [Gachon University Gil Hospital, Incheon (Korea, Republic of)

    2015-03-15

    The aim of this study was to evaluate the safety and efficacy of SEAL aortic stent-graft for abdominal aortoiliac aneurysms. Between October 2007 and January 2014, 33 patients with abdominal aortoiliac aneurysms were treated with SEAL aortic stent-graft. We evaluated the technical success rate, clinical and CT follow-up periods, major complications, need for additional interventional treatment, aneurysm-related mortality and clinical success rate. SEAL bifurcated aortic stent-graft was successfully placed in 32 patients (97%). Clinical and CT follow-up periods were 24 and 14 months, respectively. Endoleak developed in 13 patients (41%): spontaneous regression or decrease in 6, need for additional treatment in 4 and follow-up loss in 3. Significant stenosis of stent-graft occurred in 4 patients (12%) and was treated with stenting in 3. Migration of stent-graft was noted in 3 patients (9%) and treated with additional stent-grafting. Aneurysm-related mortality was 9% (3 of 33). The placement of SEAL stent-graft was effective in 26 patients (79%). The placement of SEAL aortic stent-graft was safe and effective in patients with aneurysms of abdominal aorta and iliac arteries. However, complicating endoleaks, stenosis and migration of the stent-graft developed during the follow-up. Therefore, regular CT follow-up seems to be mandatory.

  2. Optimal Scanning Protocols for Dual-Energy CT Angiography in Peripheral Arterial Stents: An in Vitro Phantom Study

    Directory of Open Access Journals (Sweden)

    Abdulrahman Almutairi

    2015-05-01

    Full Text Available Objective: To identify the optimal dual-energy computed tomography (DECT scanning protocol for peripheral arterial stents while achieving a low radiation dose, while still maintaining diagnostic image quality, as determined by an in vitro phantom study. Methods: Dual-energy scans in monochromatic spectral imaging mode were performed on a peripheral arterial phantom with use of three gemstone spectral imaging (GSI protocols, three pitch values, and four kiloelectron volts (keV ranges. A total of 15 stents of different sizes, materials, and designs were deployed in the phantom. Image noise, the signal-to-noise ratio (SNR, different levels of adaptive statistical iterative reconstruction (ASIR, and the four levels of monochromatic energy for DECT imaging of peripheral arterial stents were measured and compared to determine the optimal protocols. Results: A total of 36 scans with 180 datasets were reconstructed from a combination of different protocols. There was a significant reduction of image noise with a higher SNR from monochromatic energy images between 65 and 70 keV in all investigated preset GSI protocols (p < 0.05. In addition, significant effects were found from the main effect analysis for these factors: GSI, pitch, and keV (p = 0.001. In contrast, there was significant interaction on the unstented area between GSI and ASIR (p = 0.015 and a very high significant difference between keV and ASIR (p < 0.001. A radiation dose reduction of 50% was achieved. Conclusions: The optimal scanning protocol and energy level in the phantom study were GSI-48, pitch value 0.984, and 65 keV, which resulted in lower image noise and a lower radiation dose, but with acceptable diagnostic images.

  3. Optimal Scanning Protocols for Dual-Energy CT Angiography in Peripheral Arterial Stents: An in Vitro Phantom Study

    Science.gov (United States)

    Almutairi, Abdulrahman; Sun, Zhonghua; Al Safran, Zakariya; Poovathumkadavi, Abduljaleel; Albader, Suha; Ifdailat, Husam

    2015-01-01

    Objective: To identify the optimal dual-energy computed tomography (DECT) scanning protocol for peripheral arterial stents while achieving a low radiation dose, while still maintaining diagnostic image quality, as determined by an in vitro phantom study. Methods: Dual-energy scans in monochromatic spectral imaging mode were performed on a peripheral arterial phantom with use of three gemstone spectral imaging (GSI) protocols, three pitch values, and four kiloelectron volts (keV) ranges. A total of 15 stents of different sizes, materials, and designs were deployed in the phantom. Image noise, the signal-to-noise ratio (SNR), different levels of adaptive statistical iterative reconstruction (ASIR), and the four levels of monochromatic energy for DECT imaging of peripheral arterial stents were measured and compared to determine the optimal protocols. Results: A total of 36 scans with 180 datasets were reconstructed from a combination of different protocols. There was a significant reduction of image noise with a higher SNR from monochromatic energy images between 65 and 70 keV in all investigated preset GSI protocols (p < 0.05). In addition, significant effects were found from the main effect analysis for these factors: GSI, pitch, and keV (p = 0.001). In contrast, there was significant interaction on the unstented area between GSI and ASIR (p = 0.015) and a very high significant difference between keV and ASIR (p < 0.001). A radiation dose reduction of 50% was achieved. Conclusions: The optimal scanning protocol and energy level in the phantom study were GSI-48, pitch value 0.984, and 65 keV, which resulted in lower image noise and a lower radiation dose, but with acceptable diagnostic images. PMID:26006234

  4. Long-term effects of biodegradable versus durable polymer-coated sirolimus-eluting stents on coronary arterial wall morphology assessed by virtual histology intravascular ultrasound

    Institute of Scientific and Technical Information of China (English)

    LIU Hui-liang; ZHANG Jiao; JIN Zhi-geng; LUO Jian-ping; MA Dong-xing; YANG Sheng-li; LIU Ying; HAN Wei; JING Li-min; MENG Rong-ying

    2011-01-01

    Background The durable presence of polymer coating on drug-eluting stent (DES) surface may be one of the principal reasons for stent thrombosis. The long-term coronary arterial response to biodegradable polymer-coated sirolimus-eluting stent (BSES) in vivo remained unclear.Methods Forty-one patients were enrolled in this study and virtual histology intravascular ultrasound (VH-IVUS) was performed to assess the native artery vascular responses to BSES compared with durable polymer-coated SES (DSES) during long-term follow-up (median: 8 months). The incidence of necrotic core abutting to the lumen was evaluated at follow-up.Results With similar in-stent late luminal loss (0.15 mm (0.06-0.30 mm) vs. 0.19 mm (0.03-0.30 mm), P=0.772), the overall incidence of necrotic core abutting to the lumen was significantly less in BSES group than in DSES group (44% vs.63%, P <0.05) (proximal 18%, stented site 14% and distal 12% in BSES group, proximal 19%, stented site 28% and distal 16% in DSES group). The DSES-treated segments had a significant higher incidence of necrotic core abutting to the lumen through the stent struts (73% vs. 36%, P <0.01). In addition, more multiple necrotic core abutting to the lumen was observed in DSES group (overall: 63% vs. 36%, P <0.05). Furthermore, when the stented segments with necrotic core abutting to the lumen had been taken into account only, DSES-treated lesions tended to contain more multiple necrotic core abutting to the lumen through the stent struts than BSES-treated lesions (74% vs. 33%), although there was no statistically significant difference between them (P=0.06).Conclusions By VH-IVUS analysis at follow-up, a greater frequency of stable lesion morphometry was shown in lesions treated with BSESs compared with lesions treated with DSESs. The major reason was BSES produced less toxicity to the arterial wall and facilitated neointimal healing as a result of polymer coating on DES surface biodegraded as time went by.

  5. Successful retrieval of an unexpanded coronary stent from the left main coronary artery during primary percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Šalinger-Martinović Sonja

    2011-01-01

    Full Text Available Introduction. Dislodgement and embolization of the new generation of coronary stents before their deployment are rare but could constitute a very serious complication. Case Outline. We report a case of a stent dislodgement into the left main coronary artery during the primary coronary intervention of infarct related left circumflex artery in a patient with acute myocardial infarction. The dislodged and unexpanded bare-metal stent FlexMaster 3.0x19 mm (Abbot Vascular was stranded and bended in the left main coronary artery (LMCA, probably by the tip of the guiding catheter, but stayed over the guidewire. It was successfully retrieved using a low-profile Ryujin 1.25x15 balloon catheter (Terumo that was passed through the stent, inflated and then pulled back into the guiding catheter. After that, the whole system was withdrawn through the 6 F arterial sheath via the transfemoral approach. After repeated cannulation via the 6F arterial sheath, additional BMW and ATW guidewires were introduced into the posterolateral and obtuse marginal branches and a bare-metal stent Driver (Medtronic Cardiovascular Inc 3.0x18 mm was implanted in the target lesion. Conclusion. Stent dislodgement is a rare but potentially life-threatening complication of the percutaneous coronary intervention. This incident occurring in the LMCA in particular during an acute myocardial infarction requires to be urgently resolved. The avoidance of rough manipulation with the guiding catheter and delivery system may help in preventing this kind of complications.

  6. On the role of specific drug binding in modelling arterial eluting stents

    OpenAIRE

    McGinty, Sean; Pontrelli, Giuseppe

    2016-01-01

    In this paper we consider drug binding in the arterial wall following\\ud delivery by a drug-eluting stent. Whilst it is now generally accepted that a\\ud non-linear saturable reversible binding model is required to properly describe\\ud the binding process, the precise form of the binding model varies between authors.\\ud Our particular interest in this manuscript is in assessing to what extent\\ud modelling specific and non-specific binding in the arterial wall as separate\\ud phases is important...

  7. Emergent Unilateral Renal Artery Stenting for Treatment of Flash Pulmonary Edema: Fact or Fiction?

    Directory of Open Access Journals (Sweden)

    Asaad Akbar Khan

    2015-01-01

    Full Text Available Flash pulmonary edema is characteristically sudden in onset with rapid resolution once appropriate therapy has been instituted (Messerli et al., 2011. Acute increase of left ventricular (LV end diastolic pressure is the usual cause of sudden decompensated cardiac failure in this patient population. Presence of bilateral renal artery stenosis or unilateral stenosis in combination with a single functional kidney in the susceptible cohort is usually blamed for this condition. We describe a patient who presented with flash pulmonary edema in the setting of normal coronary arteries. Our case is distinct as our patient developed flash pulmonary edema secondary to unilateral renal artery stenosis in the presence of bilateral functioning kidneys. Percutaneous stent implantation in the affected renal artery resulted in rapid resolution of pulmonary edema.

  8. Emergent Unilateral Renal Artery Stenting for Treatment of Flash Pulmonary Edema: Fact or Fiction?

    Science.gov (United States)

    Khan, Asaad Akbar; McFadden, Eugene Patrick

    2015-01-01

    Flash pulmonary edema is characteristically sudden in onset with rapid resolution once appropriate therapy has been instituted (Messerli et al., 2011). Acute increase of left ventricular (LV) end diastolic pressure is the usual cause of sudden decompensated cardiac failure in this patient population. Presence of bilateral renal artery stenosis or unilateral stenosis in combination with a single functional kidney in the susceptible cohort is usually blamed for this condition. We describe a patient who presented with flash pulmonary edema in the setting of normal coronary arteries. Our case is distinct as our patient developed flash pulmonary edema secondary to unilateral renal artery stenosis in the presence of bilateral functioning kidneys. Percutaneous stent implantation in the affected renal artery resulted in rapid resolution of pulmonary edema. PMID:25793128

  9. Impact of baseline characteristics on outcomes of carotid artery stenting in acute ischemic stroke patients

    Directory of Open Access Journals (Sweden)

    Yu CS

    2016-03-01

    Full Text Available Cheng-Sheng Yu,1,* Chih-Ming Lin,2,3,* Chi-Kuang Liu,4 Henry Horng-Shing Lu1 1Institute of Statistics and Big Data Research Center, National Chiao Tung University, Hsinchu, 2Stroke Centre and Department of Neurology, Chunghua Christian Hospital, Chunghua, 3Graduate Institute of Biological Science and Technology, National Chiao Tung University, Hsinchu, 4Department of Medical Imaging, Chunghua Christian Hospital, Chunghua, Taiwan, Republic of China *These authors contributed equally to this work Abstract: Carotid artery stenting is an effective treatment for ischemic stroke patients with moderate-to-severe carotid artery stenosis. However, the midterm outcome for patients undergoing this procedure varies considerably with baseline characteristics. To determine the impact of baseline characteristics on outcomes following carotid artery stenting, data from 107 eligible patients with a first episode of ischemic stroke were collected by retrospective chart review. A modified Rankin Scale (mRS was used to divide patients into two baseline groups, mRS ≤2 and mRS >2. A three-step decision-tree statistical analysis was conducted. After weighting the decision-tree parameters, the following impact hierarchy was obtained: admission low-density lipoprotein, gouty arthritis, chronic kidney disease, ipsilateral common carotid artery resistance index, contralateral ophthalmic artery resistance index, sex, and dyslipidemia. The finite-state machine model demonstrated that, in patients with baseline mRS ≤2, 46% had an improved mRS score at follow-up, whereas 54% had a stable mRS score. In patients with baseline mRS >2, a stable mRS score was observed in 75%, improved score in 23%, and a poorer score in 2%. Admission low-density lipoprotein was the strongest predictive factor influencing poststenting outcome. In addition, our study provides further evidence that carotid artery stenting can be of benefit in first-time ischemic stroke patients with baseline m

  10. Covered stents for endovascular repair of iatrogenic injuries of iliac and femoral arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kufner, Sebastian, E-mail: kufners@dhm.mhn.de [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Cassese, Salvatore; Groha, Philipp; Byrne, Robert A. [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Schunkert, Heribert; Kastrati, Adnan [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Ott, Ilka; Fusaro, Massimiliano [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany)

    2015-04-15

    Background: The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. A strategy of percutaneous transluminal angioplasty (PTA) with covered stent (CS) may represent a valuable alternative to open surgery. However, systematic evaluations of CS in this setting represent a scientific gap. In the present study, we investigate the procedural and clinical outcomes associated with PTA and CS implantation to repair iatrogenic injuries of peripheral arteries. Methods: All patients undergoing PTA with CS for endovascular repair of iatrogenic injuries of peripheral arteries between August 2010 and July 2013 at our Institution were retrospectively analyzed. The primary endpoint was the technical success. Secondary endpoints were in-hospital mortality and cumulative death, target lesion revascularization (TLR), amputation and major stroke at 12-month follow-up. Results: During the period of observation, a total of 30 patients underwent PTA with either self-expandable (43.3%) or balloon-expandable CS (56.7%) for iatrogenic injuries of peripheral arteries. Injuries consisted of perforation/rupture (76.7%), arteriovenous fistula (16.7%) and pseudoaneurysm (6.7%) of iliac–femoral arteries. Technical success was achieved in all cases. Median follow-up was 409 days [210–907]. The incidence of in-hospital mortality was 10.0%. At 12-month follow-up, the incidence of death, TLR, amputation and major stroke was 20.0%, 17.0%, 3.3% and 6.7%, respectively. Conclusion: The use of covered stents for endovascular repair of iatrogenic injuries of peripheral arteries shows a high technical success and may be alternative to surgery. Further studies with larger populations are needed to confirm these preliminary findings. - Highlights: • The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. • Percutaneous transluminal angioplasty with

  11. Long-term effect of stenting in unprotected left main coronary artery disease in the elderly

    Institute of Scientific and Technical Information of China (English)

    Caiyi LU; Pinfa LIU; Jicai ZANG; Shiwen WANG; Lingling LIU; Qiao XUE; Xinli WU; Taohong HU; Pingshuan DONG; Zhiping WANG; Shenfang TIAN

    2005-01-01

    To evaluate the feasibility, safety and efficacy of percutaneous stent implantation for treating left main coronary artery (LMCA) stenosis. Methods Consecutive patients with unprotected left main coronary artery disease treated by stent-based percutaneous intervention (PCI) at 6 medical centers in China were enrolled. Procedural data and clinical outcomes were obtained from all patients. Results From January 2001 to December 2004, 138 patients (79 males and 59 females; mean age: 69.7±5.8 years)underwent PCI for LMCA stenosis. Bare metal stents (BMS) were implanted in 51 patients with non-bifurcational lesions and in 5 patients with bifurcational lesions from January of 2001 to June of 2003 (BMS group);. Drug eluting stents (DES) were used unselectively to cover both bifurcational and non-bifurcational lesions in 86 patients from July of 2003 to December of 2004 (DES group). Procedural success rate of the 138 cases was 98% (135/138). One patient (0.7%) with bifurcation lesion who was treated with DES died from severe heart failure 2 weeks after the procedure. During a mean follow up period of 21.3 ± 5.6 months, one patient died from renal failure, one from sudden cardiac death, 4 underwent target lesion revascularization (TLR) in the BMS group, which all occurred in patients with bifurcational lesions; whereas in the DES group no deaths occurred and only one patient with bifurcational lesion had TLR. Conclusions (1) PCI is feasible and relatively safe to treat unprotected left main coronary artery disease in elderly patients at medical centers with experienced professionals. (2) BMS and DES have similar immediate and long-term efficacy in the treatment of ostium and shaft lesions of the LMCA. (3) DES are strongly suggested in the therapy of distal bifurcation lesion of unprotected LMCA.

  12. Metabolic syndrome and coronary artery disease in Ossabaw compared with Yucatan swine.

    Science.gov (United States)

    Neeb, Zachary P; Edwards, Jason M; Alloosh, Mouhamad; Long, Xin; Mokelke, Eric A; Sturek, Michael

    2010-08-01

    Metabolic syndrome (MetS), a compilation of associated risk factors, increases the risk of type 2 diabetes and coronary artery disease (CAD, atherosclerosis), which can progress to the point of artery occlusion. Stents are the primary interventional treatment for occlusive CAD, and patients with MetS and hyperinsulinemia have increased restenosis. Because of its thrifty genotype, the Ossabaw pig is a model of MetS. We tested the hypothesis that, when fed high-fat diet, Ossabaw swine develop more features of MetS, greater native CAD, and greater stent-induced CAD than do Yucatan swine. Animals of each breed were divided randomly into 2 groups and fed 2 different calorie-matched diets for 40 wk: control diet (C) and high-fat, high-cholesterol atherogenic diet (H). A bare metal stent was placed in the circumflex artery, and pigs were allowed to recover for 3 wk. Characteristics of MetS, macrovascular and microvascular CAD, in-stent stenosis, and Ca(2+) signaling in coronary smooth muscle cells were evaluated. MetS characteristics including, obesity, glucose intolerance, hyperinsulinemia, and elevated arterial pressure were elevated in Ossabaw swine compared to Yucatan swine. Ossabaw swine with MetS had more extensive and diffuse native CAD and in-stent stenosis and impaired coronary blood flow regulation compared with Yucatan. In-stent atherosclerotic lesions in Ossabaw coronary arteries were less fibrous and more cellular. Coronary smooth muscle cells from Ossabaw had impaired Ca(2+) efflux and intracellular sequestration versus cells from Yucatan swine. Therefore, Ossabaw swine are a superior model of MetS, subsequent CAD, and cellular Ca(2+) signaling defects, whereas Yucatan swine are leaner and relatively resistant to MetS and CAD.

  13. Long-term outcome in patients treated with sirolimus-eluting stents in complex coronary artery lesions

    DEFF Research Database (Denmark)

    Kelbaek, Henning; Kløvgaard, Lene; Helqvist, Steffen;

    2008-01-01

    data of the long-term outcome of patients with complex coronary artery lesions. METHODS: We randomly assigned 322 patients with total coronary occlusions or lesions located in bifurcations, ostial, or angulated segments of the coronary arteries to have SES or BMS implanted. RESULTS: At 3 years, major...... benefit was observed up to 3 years after implantation of SES in patients with complex coronary artery lesions. The rate of late adverse events was similar in the 2 groups, and stent thromboses occurred rarely after 1 year. (Sirolimus Eluting Stents in Complex Coronary Lesions [SCANDSTENT]; NCT00151658)...

  14. Preparation and surface characterization of HMDI-activated 316L stainless steel for coronary artery stents.

    Science.gov (United States)

    Chuang, T-W; Chen, M-H; Lin, F-H

    2008-06-01

    Poor compatibility between blood and metallic coronary artery stents is one reason for arterial restenosis. Immobilization of anticoagulant agents on the stent's surface is feasible for improving compatibility. We examined possible surface-coupling agents for anticoagulant agent immobilization. Hexamethylene diisocyanate (HMDI) and 3-aminopropyl-triethoxysilane (APTS) were examined as surface-coupling agents to activate 316L stainless steel (e.g., stent material). The activated surface was characterized using Fourier transformation infrared spectroscopy (FTIR), atomic force microscope (AFM), surface plasmon resonance (SPR), and trinitrobenzene sulfonic acid (TNBS) assay. In FTIR analysis, HMDI and APTS were both covalently linked to 316L stainless steel. In AFM analysis, it was found that the HMDI-activated surface was smoother than the APTS-activated one. In SPR test, the shift of SPR angle for the APTS-activated surface was much higher than that for the HMDI-activated surface after being challenged with acidic solution. TNBS assay was used to determine the amount of immobilized primary amine groups. The HMDI-activated surface was found to consist of about 1.32 micromol/cm(2) amine group, whereas the APTS-activated surface consisted of only 0.89 micromol/cm(2) amine group. We conclude that the HMDI-activated surface has more desirable surface characteristics than the APTS-activated surface has, such as chemical stability and the amount of active amine groups.

  15. Revascularisation versus medical treatment in patients with stable coronary artery disease

    DEFF Research Database (Denmark)

    Windecker, Stephan; Stortecky, Stefan; Stefanini, Giulio G;

    2014-01-01

    OBJECTIVE: To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. DESIGN: Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials...... stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. DATA SOURCES: Medline and Embase from 1980......: Among patients with stable coronary artery disease, coronary artery bypass grafting reduces the risk of death, myocardial infarction, and subsequent revascularisation compared with medical treatment. All stent based coronary revascularisation technologies reduce the need for revascularisation...

  16. Endovascular treatment of peripheral arterial injury with covered stents: an experimental study in pigs

    Directory of Open Access Journals (Sweden)

    Sergio Belczak

    2011-01-01

    Full Text Available OBJECTIVE: To evaluate the feasibility of using endovascular repair to treat penetrating arterial injuries with covered stents. Feasibility was examined according to the circumferential extent of the injury. INTRODUCTION: Surgical trauma often increases the risk of major morbidity and mortality associated with vascular injury, and endovascular repair has many advantages in such situations. METHODS: Twenty white male domestic pigs weighing 28-38 kg with controlled vascular injuries were divided into four equal groups according to the circumferential extent of their vascular lesion (i.e., no lesion, lesion 50%, and complete lesion. The left common carotid artery was dissected with proximal and distal control, and this procedure was followed by controlled sectioning of the arterial wall. Local manual compression was applied for 10 min and was followed by endovascular repair with the placement of a 5x50 mm VIABHAN TM covered stent using the femoral approach. We also monitored additional variables, such as the duration of the procedures (the mean was 56.3 ± 19.1 min, ultrasound parameters (e.g., maximum arterial diameter, peak systolic and diastolic velocity, and resistance index, arteriography findings, and fluctuations in vital signs (e.g., cardiac output, arterial pressure, and central venous pressure. RESULTS: The experimental procedure was found to be feasible and reproducible. Repairs were successful in all animals in the control (no lesion and 50% group and in one pig in the complete lesion group. DISCUSSION: The endovascular repair of an arterial injury is possible, but success depends on the circumferential extent of the arterial lesion. The present experimental model, which involved endovascular techniques, highlighted important factors that must be considered in future studies involving similar animals and materials.

  17. Endovascular stents: a review of their use in peripheral arterial disease.

    Science.gov (United States)

    Kudagi, Vinod S; White, Christopher J

    2013-06-01

    Technological advances in the past decade have shifted revascularization strategies from traditional open surgical approaches toward lower-morbidity percutaneous endovascular treatments for patients with lower extremity peripheral arterial disease (PAD). The continuing advances in stent design, more than any other advances, have fueled the growth of catheter-based procedures by improving the safety, durability, and predictability of percutaneous revascularization. Although the 2007 TransAtlantic Inter-Society Consensus (TASC) guidelines recommend endovascular therapy for type A and B aortoiliac and femoropopliteal lesions, recent developments in stent technology and increased experience of interventionists have suggested that a strategy of endovascular therapy first is appropriate in experienced hands for TASC type D lesions. The role of endovascular interventions is also expanding in the treatment of limb-threatening ischemia.

  18. Beneficial effects of prolonged blood pressure control after carotid artery stenting

    Directory of Open Access Journals (Sweden)

    Chang A

    2017-01-01

    Full Text Available Anna Chang,1 Huei-Fong Hung,2 Fang-I Hsieh,3 Wei-Hung Chen,1,4 Hsu-Ling Yeh,1,5 Jiann-Horng Yeh,1,6 Hou-Chang Chiu,1,6 Li-Ming Lien1,4 1Department of Neurology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, 2Department of Cardiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, 3School of Public Health, College of Public Health, Taipei Medical University, Taipei, 4School of Medicine, College of Medicine, Taipei Medical University, Taipei, 5Institute of Public Health, National Yang-Ming University, Taipei, 6School of Medicine, College of Medicine, Fu Jen Catholic University, Taipei, Taiwan Objectives: The main purpose of this study was to investigate whether carotid artery stenting (CAS plus medicine in patients with severe carotid artery stenosis provide a better long-term blood pressure (BP control compared to other medical treatments alone. The other aim was to explore the correlation between post-CAS hypotension within 6 h and long-term BP reductions after CAS. Materials and methods: Patients with severe carotid stenosis were recruited either in the CAS group or in the medication group. BPs and the number of classes of antihypertensive agents were recorded at baseline, 6, and 12 months. Extra BP information was collected at 6 h, 3 days, and 1 month after CAS. Univariate and multivariate linear regressions were performed to test the relationship of BP changes among CAS and medication groups after 6 and 12 months of follow-up. Univariate linear regressions were also used to determine the correlations between the mean or maximal systolic BP (SBP reductions at 6 h and 1 year post-CAS. Results: In total, 72 members in the CAS group and 82 members in the medication group were recruited. Compared with the medication group, patients in the CAS group had greater BP reductions at 6 and 12 months of follow-up after adjusting for confounding factors (13.56 mmHg at 6 months, P=0.0002; 16.98 mmHg at 12 months, P<0.0001. This study also shows significant

  19. Stenting for left main stenosis in a child with anomalous origin of left coronary artery: case report

    Institute of Scientific and Technical Information of China (English)

    CHEN Ming; HONG Tao; HUO Yong

    2005-01-01

    @@ Anomalous left coronary artery (LCA) arising from right cusp is an uncommon condition. Clinical evidence has shown that this coronary anomaly is consistently related to sudden death. Current treatment options include modification of behaviour, medicine or surgery. Stents have been successfully applied for left main stenosis for a decade. We report a case of LCA arising from right cusp with left main stenosis treated with coronary stent in a child patient.

  20. Asymptotic analysis of blood flow in stented arteries: time dependency and direct simulations***

    Directory of Open Access Journals (Sweden)

    Pichon Gostaf Kirill

    2010-12-01

    Full Text Available This work aims to extend in two distinct directions results recently obtained in [10]. In a first step we focus on the possible extension of our results to the time dependent case. Whereas in the second part some preliminary numerical simulations aim to give orders of magnitudes in terms of numerical costs of direct 3D simulations. We consider, in the first part, the time dependent rough problem for a simplified heat equation in a straight channel that mimics the axial velocity under an oscillating pressure gradient. We derive first order approximations with respect to ϵ, the size of the roughness. In order to understand the problem and set up correct boundary layer approximations, we perform a time periodic fourier analysis and check that no frequency can interact with the roughness. We show rigorously on this toy problem that the boundary layers remain stationary in time (independent on the frequency number. Finally we perform numerical tests validating our theoretical approach. In the second part, we determine actual limits, when running three-dimensional blood flow simulations of the non-homogenized stented arteries. We solve the stationary Stokes equations for an artery containing a saccular aneurysm. Consecutive levels of uniform mesh refinement, serve to relate spatial resolution, problem scale, and required computation time. Test computations are presented for femoral side aneurysm, where a simplified ten-wire stent model was placed across the aneurysm throat. We advocate the proposed stent homogenization model, by concluding that an actual computation power is not sufficient to run accurate, direct simulations of a pulsatile flow in stented vessels.

  1. Safety of Early Carotid Artery Stenting after Systemic Thrombolysis: A Single Center Experience

    Directory of Open Access Journals (Sweden)

    Fabrizio Sallustio

    2012-01-01

    Full Text Available Background. Patients with acute ischemic stroke due to internal carotid artery (ICA disease are at high risk of early stroke recurrence. A combination of IV thrombolysis and early carotid artery stenting (CAS may result in more effective secondary stroke prevention. Objective. We tested safety and durability of early CAS following IV thrombolysis in stroke patients with residual stenosis in the symptomatic ICA. Methods. Of consecutive patients treated with IV rtPA, those with residual ICA stenosis ≥70% or 24 hours. The protocol included pre-rtPA MRI and MR angiography, and post-rtPA carotid ultrasound and CT angiography. Stroke severity was assessed by the NIH Stroke Scale (NIHSS. Three- and twelve-month stent patency was assessed by ultrasound. Twelve-month functional outcome was assessed by the modified Rankin Scale (mRS. Results. Of 145 consecutive IV rtPA-treated patients, 6 (4% underwent early CAS. Median age was 76 (range 67–78 years, median NIHSS at stroke onset was 12 (range 9–16 and 7 (range 7-8 before CAS. Median onset-to-CAS time was 48 (range 30–94 hours. A single self-expandable stent was implanted to cover the entire lesion in all patients. The procedure was uneventful in all patients. After 12 months, all patients had stent patency, and the functional outcome was favourable (mRS ≤ 2 in all but 1 patient experiencing a recurrent stroke for new-onset atrial fibrillation. Conclusion. This small case series of a single centre suggests that early CAS may be considered a safe alternative to CEA after IV rtPA administration in selected patients at high risk of stroke recurrence.

  2. Minimally invasive direct coronary artery bypass plus coronary stent for acute coronary syndrome: a case report

    Institute of Scientific and Technical Information of China (English)

    Caiyi Lu; Gang Wang; Qi Zhou; Jinwen Tian; Lei Gao; Shenhua Zhou; Jinyue Zhai; Rui Chen; Zhongren Zhao; Cangqing Gao; Shiwen Wang; Yuxiao Zhang; Ming Yang; Qiao Xue; Cangsong Xiao; Wei Gao; Yang Wu

    2008-01-01

    A 69-year old female patient was admitted because of 3 days of worsened chest pain.Coronary angiography showed60% stenosis of distal left main stem,chronic total occlusion of left anterior descending (LAD),70% stenosis at the ostium of a smallleft circumflex,70-90%stenosis at the paroxysmal and middle part of a dominant fight coronary artery (RCA),and a normal left internalmammary artery (LIMA) with normal origination and orientation.Percutaneous intervention was attempted but failed on the occludedlesion of LAD.The patient received minimally invasive direct coronary artery bypass (MIDCAB) with left LIMA isolation by Davincirobot.Eleven days later,the RCA lesion was treated by Sirolimus Rapamicin eluting stents implantation percutaneously.Then thepatient was discharged uneventfully after 3 days hospitalization.Our experience suggests that two stop shops of hybrid technique befeasible and safe in the treatment of elderly patient with multiple coronary diseases.

  3. Arterial healing following primary PCI using the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) versus the durable polymer everolimus-eluting metallic stent (XIENCE) in patients with acute ST-elevation myocardial infarction

    DEFF Research Database (Denmark)

    Räber, Lorenz; Onuma, Yoshinobu; Brugaletta, Salvatore

    2015-01-01

    Aims: The Absorb bioresorbable vascular scaffold (Absorb BVS) provides similar clinical outcomes compared with a durable polymer-based everolimus-eluting metallic stent (EES) in stable coronary artery disease patients. ST-elevation myocardial infarction (STEMI) lesions have been associated...... with delayed arterial healing and impaired stent-related outcomes. The purpose of the present study is to compare directly the arterial healing response, angiographic efficacy and clinical outcomes between the Absorb BVS and metallic EES. Methods and results: A total of 191 patients with acute STEMI were...... randomly allocated to treatment with the Absorb BVS or a metallic EES 1:1. The primary endpoint is the neointimal healing (NIH) score, which is calculated based on a score taking into consideration the presence of uncovered and malapposed stent struts, intraluminal filling defects and excessive neointimal...

  4. Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model.

    Science.gov (United States)

    Hikichi, Yutaka; Umezu, Mitsuo; Node, Koichi; Iwasaki, Kiyotaka

    2017-01-01

    Stent struts protruding into ostial side branch called "jailed strut" at bifurcation lesions is a likely cause of thrombus formation. We aimed to investigate the influences of multiple kissing balloon inflation (KBI) for stent expansion, and stent platform design, respectively, on the reduction of incomplete stent apposition area (ISA area) caused by jailed struts at a side-branch ostium, using a three-dimensional elastic left main (LM) bifurcated coronary artery model. The referenced LM bifurcation angle data of 209 patients were stratified by tertiles focusing on the angle between the LM trunk (LMT) and left anterior descending artery (LAD). A bifurcation model was fabricated with angles of 129°, 122.2°, and 76.4° for LMT-LAD, LMT-left circumflex (LCx), and LAD-LCx, respectively, and with diameters of 5, 3.75, and 3.5 mm for LMT, LAD, and LCx, respectively; these diameters fulfill Murray's law. A 75 % stenosis was included along the LMT. One-time and three-time KBIs were conducted using two-link Nobori and three-link Xience Xpedition (n = 6 each). The ISA area was quantified using micro-CT. Three-time KBI was effective in reducing the ISA area compared with one-time KBI for both the Nobori (p = 0.05) and Xience Xpedition (p = 0.07). The ISA area was smaller in the Nobori than in the Xience Xpedition, both in one-time and three-time KBI (one-time KBI: p = 0.003; three-time KBI: p = 0.001). Our findings of this study on reducing the ISA area by focusing on an interventional technique and stent design may help to improve coronary bifurcation intervention for a possibly better long-term clinical outcome.

  5. Experience with the Treatment of Patients with Arterial Hypertension and Concomitant Atrial Fibrillation Stented for Coronary Stenoses and Atherothombosis

    OpenAIRE

    Seredyuk, N.M.; Vakaliuk, I.P.; Yakymchuk, V.M.; Kupnovytska, I.G.; Volynskiy, A.I.; Petrovskiy, R.V.; Sorohtey, L.V.

    2017-01-01

    Material and methods. This study included 1008 patients with arterial hypertension (AH) in combination with coronary artery disease (CAD) and atrial fibrillation (AF). All patients underwent selective coronary angiography, dynamic measurement of blood pressure (BP), recording an electrocardiogram, echocardiogram, coagulogram, lipid profile and other clinical and biochemical studies. Results. For the first time, it was found that comorbidity of AH, CAD and AF after coronary artery stenting for...

  6. Vertebral artery orifice stenosis: a report of 43 cases from northwest iran treated with angioplasty and stenting.

    Science.gov (United States)

    Mohammadian, R; Najaran, A; Sohrabi, B; Mansourizadeh, R; Mohammadian, F; Nasiri, B; Farhoudi, M

    2011-10-31

    More than one quarter of all transient ischemic attacks (TIA's) and ischemic strokes involve tissue supplied by the vertebrobasilar (VB) circulation. Vertebral artery stenotic lesion, particularly at the origin of the vertebral artery, is not uncommon but it is a less studied area. Here we present our endovascular treatment experience in a group of patients with vertebral artery orifice stenosis. We enrolled a group of patients with vertebral artery orifice stenosis who presented with confirmed posterior circulation stroke. Vertebrobasilar insufficiency syndrome was confirmed by imaging studies and clinical findings. Vertebral artery stenosis diagnosed by CT or MR Angiography and confirmed by Conventional and digital subtraction angiography (DSA). Angiography was performed by using of femoral or radial artery approach. From October 2008 to January 2010, forty-three consecutive patients (69.8% men) underwent stent placement for symptomatic vertebral artery orifice stenosis. Mean degree of stenosis was 70.45 +/- 7.455 percent and mean age was 71.65 +/- 7.743 years . In the 22 patients (22/43, 51.16%) stenosis were in left side. In the thirty patients (30/43, 69.6%) there was evidence of atherosclerotic disease in the internal carotid artery and in the 23% contra lateral vertebral artery was involved. There were five different cases with left renal artery stenosis especially in the men with left vertebral artery stenosis. Initial technical success rate was 100%. No cerebrovascular complications or embolic events occurred. Six months control angiography follow-up revealed one patient with stent occlusion and moderate (40%) restenosis in the another patient. According to our finding angioplasty and stenting for vertebral artery orifice stenosis is safe and effective. Patients with vertebral artery orifice disease frequently have coexistent atherosclerotic stenosis in the other major extracranial arteries including carotid and renal arteries.

  7. Stent-assisted coil embolization of a recurrent posterior cerebral artery aneurysm following surgical clipping.

    Science.gov (United States)

    Takeshita, Tomonori; Nagamine, Tomoaki; Ishihara, Kohei; Kaku, Yasuhiko

    2017-02-01

    Posterior cerebral artery (PCA) aneurysms are rare, and direct surgery of these is considered difficult. Coil embolization of PCA aneurysms is becoming popular. However, it is difficult to completely obliterate the aneurysm while preserving the flow of the parent artery in large or giant PCA aneurysms with a wide neck with this technique. We report a case of a large and wide-necked PCA aneurysm with multiple recurrences following successful surgical clipping and coil embolization. A 77-year-old man with a large unruptured right PCA (P2) aneurysm was successfully treated by surgical clipping. Postoperative digital subtraction angiography (DSA) showed complete aneurismal occlusion. Four years afterward, the aneurysm recurred and grew toward the contralateral. Surgical retreatment of this complicated aneurysm was considered difficult, with a substantial risk of complications. Therefore, the aneurysm was treated with an endovascular procedure. Because simple coil embolization was not expected to achieve satisfactory obliteration of the aneurysm with preservation of parent artery patency, we used stent-assisted coil embolization. The patient tolerated the treatment well. On DSA obtained six months after the first endovascular treatment, coil compaction and recanalization of the aneurysm were detected. A second coil embolization was successfully performed without any complications. The aneurysm was stable during the next six-month follow-up. Stent-assisted coil embolization may be feasible and effective for such postoperatively complicated aneurysms.

  8. Long-term outcome in patients treated with sirolimus-eluting stents in complex coronary artery lesions: 3-year results of the SCANDSTENT (Stenting Coronary Arteries in Non-Stress/Benestent Disease) trial

    DEFF Research Database (Denmark)

    Kelbaek, H.; Klovgaard, L.; Helqvist, S.;

    2008-01-01

    data of the long-term outcome of patients with complex coronary artery lesions. METHODS: We randomly assigned 322 patients with total coronary occlusions or lesions located in bifurcations, ostial, or angulated segments of the coronary arteries to have SES or BMS implanted. RESULTS: At 3 years, major...... performed between 1 and 3 years after the index treatment (p = NS). According to revised definitions, stent thrombosis occurred in 5 patients (3.1%) in the SES group and in 7 patients (4.4%) in the BMS group (p = NS); very late stent thrombosis was observed in 4 versus 1 patient. CONCLUSIONS: A continued...

  9. Comparing coronary stent material performance on a common geometric platform through simulated bench testing.

    Science.gov (United States)

    Grogan, J A; Leen, S B; McHugh, P E

    2012-08-01

    Absorbable metallic stents (AMSs) are a newly emerging cardiovascular technology which has the potential to eliminate long-term patient health risks associated with conventional permanent stents. AMSs developed to date have consisted of magnesium alloys or iron, materials with inferior mechanical properties to those used in permanent stents, such as stainless steel and cobalt-chromium alloys. However, for AMSs to be feasible for widespread clinical use it is important that their performance is comparable to modern permanent stents. To date, the performances of magnesium, iron, and permanent stent materials have not been compared on a common stent platform for a range of stent performance metrics, such as flexibility, radial strength, and recoil. In this study, this comparison is made through simulated bench testing, based on finite-element modelling. The significance of this study is that it allows potential limitations in current AMS performance to be identified, which will aid in focusing future AMS design. This study also allows the identification of limitations in current AMS materials, thereby informing the on-going development of candidate biodegradable alloys. The results indicate that the AMSs studied here can match the recoil characteristics and radial strength of modern permanent stents; however, to achieve this, larger strut dimensions are required. It is also predicted that the AMSs studied are inferior to permanent stents in terms of maximum absolute curvature and longitudinal stiffness.

  10. Clinical Comparison of Outcomes of Early versus Delayed Carotid Artery Stenting for Symptomatic Cerebral Watershed Infarction due to Stenosis of the Proximal Internal Carotid Artery

    Directory of Open Access Journals (Sweden)

    Huakun Liu

    2016-01-01

    Full Text Available The aim of this study was to compare the clinical outcomes of early versus delayed carotid artery stenting (CAS for symptomatic cerebral watershed infarction (sCWI patients due to stenosis of the proximal internal carotid artery. We retrospectively collected clinical data of those who underwent early or delayed CAS from March 2011 to April 2014. The time of early CAS and delayed CAS was within a week of symptom onset and after four weeks from symptom onset. Clinical data such as second stroke, the National Institutes of Health Stroke Scale (NHISS score, and modified Rankin Scale (mRS score and periprocedural complications were collected. The rate of second stroke in early CAS group is lower when compared to that of delayed CAS group. There was no significant difference regarding periprocedural complications in both groups. There was a significant difference regarding mean NHISS score 90 days after CAS in two groups. Early CAS group had a significant better good outcome (mRS score ≤ 2 than delayed CAS group. We suggest early CAS for sCWI due to severe proximal internal carotid artery stenosis as it provides lower rate of second stroke, comparable periprocedural complications, and better functional outcomes compared to that of delayed CAS.

  11. Lateral abdominal wall hematoma as a rare complication after carotid artery stenting: a case report

    Directory of Open Access Journals (Sweden)

    Satomi Jyunichiro

    2009-11-01

    Full Text Available Abstract Abdominal wall hematoma is a rare and life-threatening complication after carotid artery stenting (CAS, but it can occur when activated clotting time is prolonged. We report a right lateral abdominal wall hematoma caused by rupture of the superficial circumflex iliac artery after CAS in a 72-year-old man with severe stenosis of the origin of the right internal carotid artery. We performed CAS for the targeted lesion while activated clotting time exceeded 300 seconds. After 2 hours, he complained of right lateral abdominal pain. Abdominal computed tomography revealed an extensive hematoma in the right lateral abdominal wall. Activated clotting time was 180 seconds at this point. Seven hours later, he developed hypotension and hemoglobin level dropped to 11.3 g/dl. Subsequent computed tomography showed enlargement of the hematoma. Emergent selective angiography of the external iliac artery revealed active bleeding from the right superficial circumflex iliac artery. Transcatheter arterial embolization with Gelfoam and microcoils was performed successfully. With more CAS procedures being performed, it is important for endovascular surgeons and radiologists to consider the possibility of abdominal wall hematoma in this situation.

  12. Triple antithrombotic therapy in patients with atrial fibrillation undergoing coronary artery stenting: hovering among bleeding risk, thromboembolic events, and stent thrombosis

    Directory of Open Access Journals (Sweden)

    Menozzi Mila

    2012-10-01

    Full Text Available Abstract Dual antiplatelet treatment with aspirin and clopidogrel is the antithrombotic treatment recommended after an acute coronary syndrome and/or coronary artery stenting. The evidence for optimal antiplatelet therapy for patients, in whom long-term treatment oral anticoagulation is mandatory, is however scarce. To evaluate the safety and efficacy of the various antithrombotic strategies adopted in this population, we reviewed the available evidence on the management of patients receiving oral anticoagulation, such as a vitamin-k-antagonists, referred for coronary artery stenting. Atrial fibrillation is the most frequent indication for oral anticoagulation. The need of starting antiplatelet therapy in this clinical scenario raises concerns about the combination to choose: triple therapy with warfarin, aspirin, and a thienopyridine being the most frequent and advised. The safety of this regimen appeared suboptimal because of an increased risk in hemorrhagic complications. On the other hand, the combination of oral anticoagulation and an antiplatelet agent is suboptimal in preventing thromboembolic events and stent thrombosis; dual antiplatelet therapy may be considered only when a high hemorrhagic risk and low thromboembolic risk are perceived. Indeed, the need for prolonged multiple-drug antithrombotic therapy increases the bleeding risks when drug eluting stents are used. Since current evidence derives mainly from small, single-center and retrospective studies, large-scale prospective multicenter studies are urgently needed.

  13. Carotid artery stenting in patients with coexistent carotid and coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    LUO Jian-fang; HUANG Wen-hui; WANG Shuo; DAI Cheng-bo; LI Guang; CHEN Ji-yan; ZHOU Ying-ling; WANG Li-juan

    2007-01-01

    @@ Atherosclerotic disease, as a systemic process, affects all arteries to varying degrees. In particular,coexistent carotid and coronary artery diseases are common; Management of such patients has been a point of continuing controversy.

  14. Is it necessary to stent renal artery stenosis patients before cardiopulmonary bypass procedures?

    Institute of Scientific and Technical Information of China (English)

    ZHENG Bin; YAN Hong-bing; LIU Rui-fang; CHENG Shu-juan; WANG Jian; ZHAO Han-jun; SONG Li

    2011-01-01

    Background Acute kidney injury (AKI) is associated with poor prognosis after cardiopulmonary bypass. The aim of this retrospective study was to investigate whether stent implantation before cardiopulmonary bypass has beneficial effect on development of AKI in renal artery stenosis (RAS) patients.Methods In this retrospective study, patients with abnormal baseline serum creatinine (SCr, >106 μmol/L) were not included. Included patients (n=69) were divided into two groups. Group 1 included 31 RAS patients receiving no stent implantation before cardiopulmonary bypass. Group 2 included 38 RAS patients having received stent implantation just before cardiopulmonary bypass. To assess AKI after cardiopulmonary bypass, serum urea nitrogen, SCr and creatinine clearance were recorded at baseline, at the end of operation, during the first and second postoperative 24 hours.Results Baseline characteristics were similar between groups. Serum urea nitrogen, SCr, creatinine clearance before and after cardiopulmonary bypass were also similar class groups. Incidence of AKI in group 1 was not significantly different from group 2. In group 1, AKI defined by RIFLE between occurred in 7 (22.6%) patients: 5 (16.1%) with RIFLE-R,2 (6.5%) with RIFLE-I, and no patients with RIFLE-F. In group 2, 10 patients (26.3%) had an episode of AKI during hospitalization: 6 (15.8%) had RIFLE-R, 4 (10.5%) had RIFLE-I, and no patients had RIFLE-F.Conclusions There are no data suggesting that it is necessary to stent RAS patients with normal SCr before cardiopulmonary bypass. However, it cannot be concluded that RAS is not associated with AKI after cardiopulmonary bypass.

  15. Proliferation and C-myc Gene Expression of Smooth Muscle Cells in Rabbit Carotid Artery after Stenting

    Institute of Scientific and Technical Information of China (English)

    张新霞; 崔长琮; 胡雪松; 魏文斌; 李松; 许香广

    2004-01-01

    Objectives To investigate the proliferation of smooth muscle cells (VSMCs) and the expression of c-myc gene in rabbit carotid arteries after stenting. Methods Platinium-Iridium stent were implanted into the right carotid arteries of 16 rabbits under vision. 7,14,30 and 90 days after the stenting procedure, morphological changes of VSMCs were observed under light and transmission electron microscope. The c-myc gene expression was detected by in situ hybridization (ISH) and immunohistochemical staining. Results 7 days after stenting, the phenotype of VSMCs changed from contractile to synthetic phenotype; there were a number of proliferative VSMCs in the neointima. At 14 and 30 days, there were synthetic and transitive VSMCs. At 90 days, the phenotype of VSMCs recovered to contractile phenotype.The ultrastructure of typical synthetic phenotype of VSMCs were round, containing a large amount of rough endoplasmic reticulum and mitochondria. Cmyc expression were positive both by ISH and immunohistochemical staining. Conclusions C-myc gene expression increases and closely relates to VSMCs proliferation after stenting. It may play an important role in the in-stent restenosis.

  16. Percutaneous transluminal renal angioplasty with stent is effective for blood pressure control and renal function improvement in atherosclerotic renal artery stenosis patients

    Institute of Scientific and Technical Information of China (English)

    LIAO Chuan-jun; YANG Bao-zhong; WANG Zhong-gao

    2012-01-01

    Background Percutaneous transluminal renal angioplasty with stent is an effective procedure for atherosclerotic renal artery stenosis.However,the decision to perform this procedure has recently raised considerable debate.The aim of this study was to assess the effects of percutaneous transluminal renal angioplasty with stent in atherosclerotic renal artery stenosis patients,especially as it relates to blood pressure control and renal function improvement.Methods A retrospective analysis was made of the clinical data from 125 atherosclerotic renal artery stenosis patients who underwent percutaneous transluminal renal angioplasty from July 2004 to June 2008 in the Department of Vascular Surgery of Beijing Chaoyang Hospital.We compared blood pressure,number of oral antihypertensive medications,and renal function changes pre and post-procedure at 24 months follow-up.Results A total of 125 atherosclerotic renal artery stenosis patients underwent percutaneous transluminal renal angioplasty and 143 stents were placed.At 24 months follow-up,both systolic and diastolic blood pressure and the number of oral antihypertensive medications were significantly reduced (P <0.05).Overall,the estimated glomerular filtration rate did not change significantly (P >0.05); however,a significant increase in estimated glomerular filtration rate was observed in the subgroup of patients with a lower baseline estimated glomerular filtration rate and in the subgroup of patients with bilateral renal artery stenosis (P <0.05).Conclusion Percutaneous transluminal renal angioplasty is a safe procedure for atherosclerotic renal artery stenosis patients,providing a significant improvement in blood pressure control and reduction in the number of oral antihypertensive medications.

  17. A new approach to the assessment of lumen visibility of coronary artery stent at various heart rates using 64-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Groen, J.M.; Greuter, M.J.W.; Ooijen, P.M.A. van; Oudkerk, M. [University Medical Center Groningen, University of Groningen, Department of Radiology, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands)

    2007-07-15

    Coronary artery stent lumen visibility was assessed as a function of cardiac movement and temporal resolution with an automated objective method using an anthropomorphic moving heart phantom. Nine different coronary stents filled with contrast fluid and surrounded by fat were scanned using 64-slice multi-detector computed tomography (MDCT) at 50-100 beats/min with the moving heart phantom. Image quality was assessed by measuring in-stent CT attenuation and by a dedicated tool in the longitudinal and axial plane. Images were scored by CT attenuation and lumen visibility and compared with theoretical scoring to analyse the effect of multi-segment reconstruction (MSR). An average increase in CT attenuation of 144 {+-} 59 HU and average diminished lumen visibility of 29 {+-} 12% was observed at higher heart rates in both planes. A negative correlation between image quality and heart rate was non-significant for the majority of measurements (P > 0.06). No improvement of image quality was observed in using MSR. In conclusion, in-stent CT attenuation increases and lumen visibility decreases at increasing heart rate. Results obtained with the automated tool show similar behaviour compared with attenuation measurements. Cardiac movement during data acquisition causes approximately twice as much blurring compared with the influence of temporal resolution on image quality. (orig.)

  18. Blister-like aneurysms of the supraclinoid internal carotid artery: challenging endovascular treatment with stent-assisted coiling.

    Science.gov (United States)

    Ahn, Jung Yong; Cho, Jun Hyung; Jung, Jin Young; Lee, Byung Hee; Yoon, Pyeong Ho

    2008-09-01

    ''Blister-like'' aneurysms of the supraclinoid segment of the internal carotid artery are usually small and have fragile walls, necessitating special care to prevent rebleeding. These lesions are considered high-risk aneurysms because of the technical difficulties associated with their surgical and endovascular treatment. In this report, we describe the use of stent-assisted, repeated coil embolization in the treatment of a ruptured blister-like aneurysm that experienced rapid growth. Stent-assisted coil embolization is an alternative, but sometimes hazardous, treatment for select blister-like aneurysms. Careful serial follow-up angiography will provide documentation as to the long-term stability of the endovascularly treated blister-like aneurysm described here, but early results are encouraging. Alternatively, placement of telescoped stents or graft-stent devices offers promise for future endovascular therapy.

  19. Treatment of malignant digestive tract obstruction by combined intraluminal stent installation and intra-arterial drug infusion

    Institute of Scientific and Technical Information of China (English)

    Ai-Wu Mao; Zhong-Du Gao; Jia-Yu Xu; Ren-Jie Yancg; Xiang-Seng Xiao; Ting-Hui Jiang; Wei-Jun Jiang

    2001-01-01

    AIM To study the palliative treatment of malignant obstrution of digestive tract with placement of intraluminal stent combined with intra-arterial infusion of chemotherapeutic drugs. METHODS A total of 281 cases of digestive tract malignant obstruction were given per oral (esophagus,stomach, duodenum and jejunum), per anal (colon and rectum ) and percutaneous transhepatic ( biliary )installation of metallic stent. Among them, 205 cases received drug infusion by cannulation of tumor supplying artery with Seldingers technique. RESULTS Altogether 350 stents were installed in 281 cases, obstructive symptoms were relieved or ameliorated after installation. Occurrence of restenotic obstruction was 8 - 43 weeks among those with intraarterial drug infusion, which was later than 4 - 26 weeks in the group with only stent installation. The average survival time of the former group was 43 (3 - 105) weeks,which was significantly longer than 15 (3- 24) weeks of the latter group. CONCLUSION Intraluminal placement of stent combined with intra-arterial infusion chemotherapy is one of the effective palliative therapies for malignant obstruction of the digestive tract with symptomatic as well as etiological treatment.

  20. ANGIOPLASTIA PERCUTÁNEA CON STENT EN EL TRONCO PRINCIPAL DE LA ARTERIA CORONARIA IZQUIERDA / Percutaneous angioplasty with stent in the left main coronary artery

    Directory of Open Access Journals (Sweden)

    Javier Almeida Gómez

    2012-10-01

    Full Text Available ResumenIntroducción y objetivos: La afectación significativa del tronco común izquierdo, es la más letal de las presentaciones de la enfermedad arterial coronaria. El tratamiento de elección, es la cirugía de derivación aorto-coronaria. En varios estudios multicéntricos, se sugiere la posibilidad de tratar la enfermedad de tronco mediante el intervencionismo coronario percutáneo con implantación de prótesis endoluminal o stent. El objetivo de esta investigación fue caracterizar la angioplastia percutánea con stent en el tronco principal de la arteria coronaria izquierda. Método: Se realizó un estudio observacional, descriptivo y transversal en 21 pacientes con angioplastia percutánea con stent en el tronco principal de la arteria coronaria izquierda, realizadas en el laboratorio de Hemodinámica y Cardiología Intervencionista del Hospital "Hermanos Ameijeiras", entre enero 2010 y julio 2011. Resultados: No existió diferencia significativa en el sexo. Predominó el grupo de edad entre 50-64 años (47,6 % y el color de la piel blanca (76,19 %. El factor de riesgo cardiovascular más encontrado fue la HTA (85,71 %, seguido de dislipidemia (47,61 %. El diagnóstico más observado fue la angina de esfuerzo estable, 14 casos (66,66 %. La lesión en el cuerpo del tronco (12 pacientes, 57,1 %, fue la más encontrada, seguida de la ostial (8 casos. El tipo de stent más utilizado fue el liberador de fármacos (61,9 %, y solamente 4 pacientes presentaban troncos protegidos quirúrgicamente. Conclusiones: La mayor cantidad de casos fueron electivos, con predominio de los troncos no protegidos. El factor de riesgo coronario más encontrado fue la HTA. Se encontró asociación significativa entre la diabetes mellitus y la localización ostial de la lesión tratada. / AbstractIntroduction and Objectives: Significant impairment of the left main coronary artery is the most lethal presentation of coronary artery disease. The treatment of choice

  1. EFFECT OF STENT ABSORBED c-myc ANTISENSE OLIGODEOXYNUCLEOTIDE ON SMOOTH MUSCLE CELLS APOPTOSIS IN RABBIT CAROTID ARTERY

    Institute of Scientific and Technical Information of China (English)

    张新霞; 崔长琮; 李江; 崔翰斌; 徐仓宝; 朱参战

    2002-01-01

    Objective To investigate the effect of gelatin coated Platinium-Iridium stent absorbed c-myc antisense oligodeoxynucleotide (ASODN) on smooth muscle cells apoptosis in a normal rabbit carotid arteries. Methods Gelatin coated Platinium-Iridium stents were implanted in the right carotid arteries of 32 rabbits under vision. Animals were randomly divided into control group and treated group receiving c-myc ASODN (n=16, respectively). On 7, 14, 30 and 90 days following the stenting procedure ,morphometry for caculation of neointimal area and mean neointimal thickness were performed.The expression of c-myc protein was detected by immunohistochemical method. Apoptotic smooth muscle cells was detected by terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL). Results At 7 and 14 days after stenting,there were no detectable apoptotic cells in both groups. The apoptotic cells occurred in the neointima 30 and 90 days after stenting, and the number of apoptotic cells at 30 days were less [4.50±1.29 vs 25.75±1.89 (number/0.1mm2)] than that at 90 days [13.50±1.91 vs 41.50±6.46 (number/0.1mm2)]. Meanwhile c-myc ASODN induced more apoptotic cells than the control group(P<0.0001). c-myc protein expression was weak positive or negative in treated group and positive in control group.Conclusion c-myc ASODN can induce smooth muscle cells apoptosis after stenting in normal rabbit carotid arteries,and it can be used to prevent in-stent restenosis.

  2. Clinical Outcomes After Drug-Eluting Stents Versus Coronary Artery Bypass Surgery in High Surgical Risk Patients With Left Main or Three-Vessel Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Tonga Nfor

    2015-08-01

    Full Text Available Purpose: Previous studies comparing percutaneous coronary intervention (PCI with coronary artery bypass graft surgery (CABG in patients with unprotected left main or three-vessel coronary artery disease (LM-3VD have excluded patients at high surgical risk. We compared clinical outcomes after PCI with drug-eluting stents to CABG in high surgical risk patients with LM-3VD. Methods: Patients with symptomatic LM-3VD who had Society of Thoracic Surgeons (STS-predicted operative mortality > 5% and were undergoing either PCI with drug-eluting stents or CABG at a tertiary care center from January 2009 to December 2010 were enrolled in this nonrandomized prospective study. Results: Mean STS score was 14.5 ± 5.8% for PCI (n=83 vs. 13.6 ± 7.1% for CABG (n=187 (P=0.31. After mean follow-up of 37 months, incidence of the composite primary endpoint (death, myocardial infarction or stroke was 42.2% for PCI and 39.6% for CABG (P=0.69, hazard ratio 1.3, 95% confidence interval 0.5-2.8. There were no differences in the individual components of the primary endpoint between PCI and CABG. Repeat revascularization was 30.1% for PCI vs. 9.6% for CABG (P=0.001. Major adverse cardiac and cerebrovascular event rates were similar between PCI and CABG, 50.6% vs. 42.2%, respectively (P=0.23. Patients in the PCI group were less likely than those in the CABG group to be discharged to a nursing home (12.1% vs. 47.1%, P 5%.

  3. Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries.

    Science.gov (United States)

    Kefer, Joelle M; Coche, Emmanuel; Vanoverschelde, Jean-Louis J; Gerber, Bernhard L

    2007-01-01

    The purpose of this study was to assess the diagnostic accuracy of 16-slice multidetector-row computed tomography (MDCT) for detecting in-stent restenosis. Fifty patients with 69 previously implanted coronary stents underwent 16-slice MDCT before quantitative coronary angiography (QCA). Diagnostic accuracy of MDCT for detection of in-stent restenosis defined as >50% lumen diameter stenosis (DS) in stented and nonstented coronary segments >1.5-mm diameter was computed using QCA as reference. According to QCA, 18/69 (25%) stented segments had restenosis. In addition, 33/518 (6.4%) nonstented segments had >50% DS. In-stent restenosis was correctly identified on MDCT images in 12/18 stents, and absence of restenosis was correctly identified in 50/51 stents. Stenosis in native coronary arteries was correctly identified in 22/33 segments and correctly excluded in 482/485 segments. Thus, sensitivity (67% vs 67% p=1.0), specificity (98% vs 99%, p=0.96) and overall diagnostic accuracy (90% vs 97%, p=0.68) was similarly high for detecting in-stent restenosis as for detecting stenosis in nonstented coronary segments. MDCT has similarly high diagnostic accuracy for detecting in-stent restenosis as for detecting coronary artery disease in nonstented segments. This suggests that MDCT could be clinically useful for identification of restenosis in patients after coronary stenting.

  4. Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kefer, Joelle M.; Vanoverschelde, Jean-Louis J.; Gerber, Bernhard L. [Cliniques Universitaires St. Luc UCL, Department of Cardiology, Brussels (Belgium); Coche, Emmanuel [Cliniques Universitaires St. Luc UCL, Department of Radiology, Brussels (Belgium)

    2007-01-15

    The purpose of this study was to assess the diagnostic accuracy of 16-slice multidetector-row computed tomography (MDCT) for detecting in-stent restenosis. Fifty patients with 69 previously implanted coronary stents underwent 16-slice MDCT before quantitative coronary angiography (QCA). Diagnostic accuracy of MDCT for detection of in-stent restenosis defined as >50% lumen diameter stenosis (DS) in stented and nonstented coronary segments >1.5-mm diameter was computed using QCA as reference. According to QCA, 18/69 (25%) stented segments had restenosis. In addition, 33/518 (6.4%) nonstented segments had >50% DS. In-stent restenosis was correctly identified on MDCT images in 12/18 stents, and absence of restenosis was correctly identified in 50/51 stents. Stenosis in native coronary arteries was correctly identified in 22/33 segments and correctly excluded in 482/485 segments. Thus, sensitivity (67% vs 67% p=1.0), specificity (98% vs 99%, p=0.96) and overall diagnostic accuracy (90% vs 97%, p=0.68) was similarly high for detecting in-stent restenosis as for detecting stenosis in nonstented coronary segments. MDCT has similarly high diagnostic accuracy for detecting in-stent restenosis as for detecting coronary artery disease in nonstented segments. This suggests that MDCT could be clinically useful for identification of restenosis in patients after coronary stenting. (orig.)

  5. Endovascular treatment of aortoiliac aneurysms: From intentional occlusion of the internal iliac artery to branch iliac stent graft

    Institute of Scientific and Technical Information of China (English)

    Stevo Duvnjak

    2016-01-01

    Approximately 20%-40% of patients with abdominal aortic aneurysms can have unilateral or bilateral iliac artery aneurysms and/or ectasia. This influences and compromises the distal sealing zone during endovascular aneurysm repair. There are a few endovascular techniques that are used to treat these types of aneurysms, including intentional occlusion/over-stenting of the internal iliac artery on one or both sides, the "bell-bottom" technique, and the more recent method of using an iliac branch stent graft. In some cases, other options include the "snorkel and sandwich" technique and hybrid interventions. Pelvic ischemia, represented as buttock claudication, has been reported in 16%-55% of cases; this is followed by impotence, which has been described in 10%-17% of cases following internal iliac artery occlusion. The bellbottom technique can be used for a common iliac artery up to 24 mm in diameter given that the largest diameter of the stent graft is 28 mm. There is a paucity of data and evidence regarding the "snorkel and sandwich" technique, which can be used in a few clinical scenarios. The hybrid intervention is comprised of a surgical operation, and is not purely endovascular. The newest branch stent graft technology enables preservation of the anterograde flow of important side branches. Technical success with the newest technique ranges from 85%-96.3%, and in some small series, technical success is 100%. Buttock claudication was reported in up to 4% of patients treated with a branch stent graft at 5-year follow-up. Mid- and short-term follow-up results showed branch patency of up to 88% during the 5-6-year period. Furthermore, branch graft occlusion is a potential complication, and it has been described to occur in 1.2%-11% of cases. Iliac branch stent graft placement represents a further development in endovascular medicine, and it has a high technical success rate without serious complications.

  6. Correlates and Impact of Coronary Artery Calcifications in Women Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents

    DEFF Research Database (Denmark)

    Giustino, Gennaro; Mastoris, Ioannis; Baber, Usman;

    2016-01-01

    OBJECTIVES: The aim of this study was to investigate the clinical correlates and prognostic impact of coronary artery calcification (CAC) in women undergoing percutaneous coronary intervention with drug-eluting stents (DES). BACKGROUND: The clinical correlates and the prognostic significance of CAC...

  7. Incidence and Potential Mechanism(s) of Post-Procedural Rise of Cardiac Biomarker in Patients With Coronary Artery Narrowing After Implantation of an Everolimus-Eluting Bioresorbable Vascular Scaffold or Everolimus-Eluting Metallic Stent

    DEFF Research Database (Denmark)

    Ishibashi, Yuki; Muramatsu, Takashi; Nakatani, Shimpei;

    2015-01-01

    to Compare the Safety, Efficacy, and Performance of Absorb Everolimus Eluting Bioresorbable Vascular Scaffold System Against Xience Everolimus Eluting Coronary Stent System in the Treatment of Subjects With Ischemic Heart Disease Caused by De Novo Native Coronary Artery Lesions [ABSORB II]; NCT01425281)....

  8. Stent-assisted mechanical recanalization for symptomatic subacute or chronic middle cerebral artery occlusion

    Science.gov (United States)

    Guo, Dong; Ma, Ji; Li, Teng-Fei; Zhu, Ming; Han, Xin-Wei; Shui, Shao-Feng

    2015-01-01

    To assess the feasibility and short-term effects of treating patients with subacute or chronic middle cerebral artery (M1) occlusion by stent-assisted mechanical recanalization. Six patients with cerebral arteries occlusion underwent surgery. Six cerebral arteries occlusion in 5 patients were successfully recanalized. On postoperative day 1, four patients’ symptoms were relieved and two patients’ symptoms were exacerbated, of which one was significantly improved after 3 days, the other one’s symptoms were recovered to preoperative levels in 2 weeks. No patients died after surgery. No stroke or transient ischemic attack occurred. The average follow-up of was 4.2 months, no worsening of condition, recurrence or death occurred. The results indicate that for patients with subacute or chronic middle cerebral artery (M1) occlusion, mechanical recanalization was technically feasible under the premise of strict case screening. Mechanical recanalization is able to improve ischemic symptoms and promote dysfunction restoration. But its long-term effect remains to be evaluated by further large samples, long-term follow-up studies. PMID:26885148

  9. Comparison of Flow Impairment during Carotid Artery Stenting Using Two Types of Eccentric Filter Embolic Protection Devices

    Science.gov (United States)

    NII, Kouhei; TSUTSUMI, Masanori; MAEDA, Hitoshi; AIKAWA, Hiroshi; INOUE, Ritsuro; ETO, Ayumu; SAKAMOTO, Kimiya; MITSUTAKE, Takafumi; HANADA, Hayatsura; KAZEKAWA, Kiyoshi

    2016-01-01

    We investigated the angiographic findings and the clinical outcomes after carotid artery stenting (CAS) using two different, eccentric filter embolic protection devices (EPDs). Between July 2010 and August 2015, 175 CAS procedures were performed using a self-expandable closed-cell stent and a simple eccentric filter EPD (FilterWire EZ in 86 and Spider FX in 89 procedures). The angiographic findings (i.e., flow impairment and vasospasm) at the level of EPDs, neurologic events, and post-operative imaging results were compared between the FilterWire EZ and the Spider FX groups. The CAS was angiographically successful in all 175 procedures. However, the angiographs were obtained immediately after CAS-detected flow impairment in the distal internal carotid artery (ICA) in 11 (6.3%) and ICA spasms at the level of the EPD in 40 cases (22.9%). The incidence of these complications was higher with FilterWire EZ than Spider FX (ICA flow impairment of 10.5% vs. 2.2%, P = 0.03; vasospasm 30.2% vs. 15.7%, P = 0.03). There were nine neurologic events (5.1%); five patients were presented with transient ischemic attacks, three had minor strokes, and one had a major stroke. New MRI lesions were seen in 25 (29.1%) FilterWire-group and in 36 (40.4%) Spider-group patients. The neurologic events and new MRI lesions were not associated with the type of EPD used. Although the ICA flow impairment may result in neurologic events, there was no significant association between the FilterWire EZ and the Spider FX CAS with respect to the incidence of neurologic events by the prompt treatment such as catheter aspiration. PMID:27319302

  10. Bilateral brachial pull-through technique for stenting in a patient with stenosis of the vertebral artery origin: technical case report

    Energy Technology Data Exchange (ETDEWEB)

    Kusaka, N.; Nishiguchi, M.; Takayama, K.; Nishiura, T. [National Hospital Organization Iwakuni Clinical Center, Department of Neurosurgery, Iwakuni, Yamaguchi (Japan); Tamiya, T. [Kagawa University of Medicine, Department of Neurological Surgery, Kida-gun, Kagawa (Japan)

    2007-10-15

    Stenting for stenosis of the proximal vertebral artery (VA) is commonly performed via a femoral approach. However, iliofemoral occlusive disease such as arteriosclerosis obliterans sometimes prevents safe transfemoral access. In certain situations where both femoral access and ipsilateral brachial access are difficult because of a concomitant vascular diseases or particular anatomic setting, a contralateral brachial approach using the brachiobrachial pull-through technique may allow efficient and accurate stenting. A case of VA origin symptomatic stenosis successfully treated with stenting using the new pull-through technique from the contralateral brachial artery to the brachial artery on the affected side is described. (orig.)

  11. Effects of renal artery stenting on renal function and blood pressure in patients with atherosclerotic renovascular disease

    Institute of Scientific and Technical Information of China (English)

    张奇; 沈卫峰; 张瑞岩; 张建盛; 胡健; 张宪

    2003-01-01

    Objective To study the effects of percutaneous renal artery intervention on renal function and blood pressure in patients with renal artery stenosis. Methods Eighty-seven patients with severe uni- or bi-lateral renal artery stenosis (luminal diameter narrowing ≥70%) and clinical hypertension received renal artery stenting between January 2002 and December 2002. The changes in blood pressure and serum creatinine level and creatinine clearance (CCr) 48 hours after intervention and during 6 months of follow-up were assessed.Results Renal stenting was performed in 98 stenotic arteries of 87 patients, and the procedural success rate was 100%. Serum creatinine level was slightly elevated from (176±21) μmol/L to (179±11) μmol/L (P=0.15) 48 hours after the procedure, but significantly decreased to (149±15) μmol/L at 6 months (P<0.001). CCr was also greatly improved [(37±11) ml/min before versus (51±8) ml/min at 6 months, P<0.001]. During follow-up, 61% of the patients experienced a normal renal function. Despite conventional medical treatment, systolic and diastolic blood pressures were also significantly decreased after stenting [(163±23)/(96±13) mm Hg before versus (148±12)/(79±15) mm Hg at 6 months, all P<0.001], and hypertension was well controlled in 67% of the patients at 6 months ' follow-up.Conclusion Renal artery stenting has a high success rate and is effective in improving renal function and blood pressure for patients with severe renal artery stenosis.

  12. Angioplasty and stenting for severe vertebral artery oriifce stenosis:effects on cerebellar function remodeling veriifed by blood oxygen level-dependent functional magnetic resonance imaging

    Institute of Scientific and Technical Information of China (English)

    Bo Liu; Zhiwei Li; Peng Xie

    2014-01-01

    Vertebral artery oriifce stenting may improve blood supply of the posterior circulation of the brain to regions such as the cerebellum and brainstem. However, previous studies have mainly focused on recovery of cerebral blood lfow and perfusion in the posterior circulation after inter-ventional therapy. This study examined the effects of functional recovery of local brain tissue on cerebellar function remodeling using blood oxygen level-dependent functional magnetic reso-nance imaging before and after interventional therapy. A total of 40 Chinese patients with severe unilateral vertebral artery oriifce stenosis were enrolled in this study. Patients were equally and randomly assigned to intervention and control groups. The control group received drug treat-ment only. The intervention group received vertebral artery oriifce angioplasty and stenting+identical drug treatment to the control group. At 13 days after treatment, the Dizziness Handicap Inventory score was compared between the intervention and control groups. Cerebellar function remodeling was observed between the two groups using blood oxygen level-dependent function-al magnetic resonance imaging. The improvement in dizziness handicap and cerebellar function was more obvious in the intervention group than in the control group. Interventional therapy for severe vertebral artery oriifce stenosis may effectively promote cerebellar function remodeling and exert neuroprotective effects.

  13. A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary Arteries IV study

    Directory of Open Access Journals (Sweden)

    Teeuwen Koen

    2012-12-01

    Full Text Available Abstract Background Percutaneous recanalization of total coronary occlusion (TCO was historically hampered by high rates of restenosis and reocclusions. The PRISON II trial demonstrated a significant restenosis reduction in patients treated with sirolimus-eluting stents compared with bare metal stents for TCO. Similar reductions in restenosis were observed with the second-generation zotarolimus-eluting stent and everolimus-eluting stent. Despite favorable anti-restenotic efficacy, safety concerns evolved after identifying an increased rate of very late stent thrombosis (VLST with drug-eluting stents (DES for the treatment of TCO. Late malapposition caused by hypersensitivity reactions and chronic inflammation was suggested as a probable cause of these VLST. New DES with bioresorbable polymer coatings were developed to address these safety concerns. No randomized trials have evaluated the efficacy and safety of the new-generation DES with bioresorbable polymers in patients treated for TCO. Methods/Design The prospective, randomized, single-blinded, multicenter, non-inferiority PRISON IV trial was designed to evaluate the safety, efficacy, and angiographic outcome of hybrid sirolimus-eluting stents with bioresorbable polymers (Orsiro; Biotronik, Berlin, Germany compared with everolimus-eluting stents with durable polymers (Xience Prime/Xpedition; Abbott Vascular, Santa Clara, CA, USA in patients with successfully recanalized TCOs. In total, 330 patients have been randomly allocated to each treatment arm. Patients are eligible with estimated duration of TCO ≥4 weeks with evidence of ischemia in the supply area of the TCO. The primary endpoint is in-segment late luminal loss at 9-month follow-up angiography. Secondary angiographic endpoints include in-stent late luminal loss, minimal luminal diameter, percentage of diameter stenosis, in-stent and in-segment binary restenosis and reocclusions at 9-month follow-up. Additionally, optical coherence

  14. Stent-assisted coil embolization of a symptomatic middle cerebral artery aneurysm in an infant.

    Science.gov (United States)

    Savastano, Luis E; Chaudhary, Neeraj; Gemmete, Joseph J; Garton, Hugh J L; Maher, Cormac O; Pandey, Aditya S

    2014-11-01

    Pediatric intracranial aneurysms are rare and challenging to treat. Achieving efficacy and durability of aneurysmal occlusion while maintaining parent vessel patency requires innovative treatment strategies, especially in cases in which aneurysmal location or morphology pose substantial morbidity associated with microsurgical treatment. In the last 3 decades, endovascular treatments have had a remarkable evolution and are currently considered safe and effective therapeutic options for cerebral aneurysms. While endovascular techniques are well described in the English literature, the endovascular management of pediatric aneurysms continues to pose a challenge. In this report, the authors describe the case of a 9-month-old infant who presented with a 1-day history of acute-onset left-sided hemiparesis and left facial droop. Imaging revealed a large symptomatic saccular middle cerebral artery aneurysm. Treatment included successful stent-assisted aneurysm coiling. At follow-up, the patient continued to fare well and MR angiography confirmed complete occlusion of the aneurysm dome. This case features the youngest patient in the English literature to harbor an intracranial aneurysm successfully treated with stent-assisted coiling. Based on this experience, endovascular intervention with vascular reconstruction can be safe and effective for the treatment of infants and could further improve prognosis; however, further studies are necessary to confirm these findings.

  15. The influence of vascular anatomy on carotid artery stenting: a parametric study for damage assessment.

    Science.gov (United States)

    Iannaccone, F; Debusschere, N; De Bock, S; De Beule, M; Van Loo, D; Vermassen, F; Segers, P; Verhegghe, B

    2014-03-01

    Carotid artery stenting is emerging as an alternative technique to surgery for the treatment of symptomatic severe carotid stenosis. Clinical and experimental evidence demonstrates that both plaque morphology and biomechanical changes due to the device implantation can be possible causes of an unsuccessful treatment. In order to gain further insights of the endovascular intervention, a virtual environment based on structural finite element simulations was built to emulate the stenting procedure on generalized atherosclerotic carotid geometries which included a damage model to quantify the injury of the vessel. Five possible lesion scenarios were simulated by changing both material properties and vascular geometrical features to cover both presumed vulnerable and stable plaques. The results were analyzed with respect to lumen gain and wall stresses which are potentially related to the failure of the procedure according to previous studies. Our findings show that an elliptic lumen shape and a thinner fibrous cap with an underlying lipid pool result in higher stenosis reduction, while large calcifications and fibrotic tissue are more prone to recoil. The shielding effect of a thicker fibrous cap helps to reduce local compressive stresses in the soft plaque. The presence of a soft plaque reduces the damage in the healthy vascular structures. Contrarily, the presence of hard plaque promotes less damage volume in the fibrous cap and reduces stress peaks in this region, but they seem to increase stresses in the media-intima layer. Finally the reliability of the achieved results was put into clinical perspective.

  16. Modeling the transport of drugs eluted from stents: physical phenomena driving drug distribution in the arterial wall.

    Science.gov (United States)

    Bozsak, Franz; Chomaz, Jean-Marc; Barakat, Abdul I

    2014-04-01

    Despite recent data that suggest that the overall performance of drug-eluting stents (DES) is superior to that of bare-metal stents, the long-term safety and efficacy of DES remain controversial. The risk of late stent thrombosis associated with the use of DES has also motivated the development of a new and promising treatment option in recent years, namely drug-coated balloons (DCB). Contrary to DES where the drug of choice is typically sirolimus and its derivatives, DCB use paclitaxel since the use of sirolimus does not appear to lead to satisfactory results. Since both sirolimus and paclitaxel are highly lipophilic drugs with similar transport properties, the reason for the success of paclitaxel but not sirolimus in DCB remains unclear. Computational models of the transport of drugs eluted from DES or DCB within the arterial wall promise to enhance our understanding of the performance of these devices. The present study develops a computational model of the transport of the two drugs paclitaxel and sirolimus eluted from DES in the arterial wall. The model takes into account the multilayered structure of the arterial wall and incorporates a reversible binding model to describe drug interactions with the constituents of the arterial wall. The present results demonstrate that the transport of paclitaxel in the arterial wall is dominated by convection while the transport of sirolimus is dominated by the binding process. These marked differences suggest that drug release kinetics of DES should be tailored to the type of drug used.

  17. Rescue microsurgery with bypass and stent removal following Pipeline treatment of a giant internal carotid artery terminus aneurysm.

    Science.gov (United States)

    Bowers, Christian A; Taussky, Philip; Park, Min S; Neil, Jayson A; Couldwell, William T

    2015-12-01

    We report the microsurgical rescue and removal of a Pipeline stent embolization of a giant internal carotid artery terminus aneurysm. After the initial placement of a Pipeline Embolization Device (PED), it migrated proximally to the cavernous carotid with the distal end free in the middle of the aneurysm, resulting in only partial aneurysm neck coverage. The patient underwent microsurgical rescue with trapping, bypass, and opening of the aneurysm with PED removal. The vessel remained patent in the proximal segment previously covered by the Pipeline stent. Microsurgical rescue for definitive aneurysm treatment with PED removal can be safe and effective for aneurysms unsuccessfully treated with PED.

  18. Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study

    NARCIS (Netherlands)

    Nederkoorn, P.J.; Brown, M.M.

    2009-01-01

    Background: Carotid angioplasty with stenting is a relatively new, increasingly used, less-invasive treatment for the treatment of symptomatic carotid artery stenosis. It is being evaluated in ongoing and nearly finished randomized trials. An important factor in the evaluation of stents is the occur

  19. [Percutaneous treatment of a superficial femoral artery aneurysm using an intravascular stent-prosthesis].

    Science.gov (United States)

    Michel, C; Laffy, P Y; Leblanc, G; Riou, J Y; Chaloum, S; Maklouf, M; Le Guen, O

    1999-05-01

    One case of superficial femoral aneurysm treated percutaneously by endovascular stent graft (Passager Boston) is reported. The initial radiographic evaluation included arteriography and color doppler sonography which enable analysis of the flow path, the extent of the wall thrombus, the choice of stended graft size. The procedure of implantation was technically trouble free. The post-procedure 3D CT and arteriography demonstrated occlusion of the aneurysm and resaturation of normal flow path. The six and twelve month check confirmed the stability of the results locally and the integrity of run off vessels. In weakened and specially elderly patient percutaneous treatment of superficial femoral artery aneurysm can be carried out easily. The contribution of 3D CT is essential in follow up to ensure an optimal result and to detect any complication.

  20. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery disease who we...

  1. [Endarterectomy more favourable than stenting in symptomatic significant carotid stenosis: higher risk of ischaemic stroke or death following stenting].

    Science.gov (United States)

    Meerwaldt, Robbert; Beuk, Roland J; Huisman, Ad B; Manschot, Sanne M; Zeebregts, Clark J; Geelkerken, Robert H

    2011-01-01

    Carotid endarterectomy (CEA) has proven its value in the treatment of patients with recent significant carotid artery stenosis. Percutaneous transluminal angioplasty with carotid artery stenting ('stenting' in short) is an alternative to CEA. The results of stenting and CEA in patients with symptomatic significant carotid artery stenosis were evaluated in 9 prospective randomized controlled trials and 11 meta-analyses. Almost all of these trials failed to show superiority of stenting to CEA. According to the 4 largest and most recent studies in this field the risk of a stroke or death within 30 days after the intervention is considerably higher following stenting than following CEA. In the long run the results of stenting and CEA seem to be comparable. CEA remains the gold standard in treatment of significant carotid artery stenosis, in particular in patients older than 70.

  2. Carotid stenting through the right brachial approach for left internal carotid artery stenosis and bovine aortic arch configuration

    Energy Technology Data Exchange (ETDEWEB)

    Montorsi, Piero; Galli, Stefano; Ravagnani, Paolo; Ghulam Ali, Sarah; Trabattoni, Daniela; Fabbiocchi, Franco; Lualdi, Alessandro; Ballerini, Giovanni; Andreini, Daniele; Pontone, Gianluca; Annoni, Andrea; Bartorelli, Antonio L. [Institute of Cardiology University of Milan, Centro Cardiologico Monzino, IRCCS, Milan (Italy)

    2009-08-15

    Unfavorable complex anatomy or congenital anomalies of supra-aortic vessel take-off may increase carotid artery stenting (CAS) procedural difficulties and complications through the femoral route. We assessed the feasibility, safety, and efficacy of CAS through the right brachial approach in patients in whom left internal carotid artery stenosis and bovine aortic arch configuration were identified with computed tomography (CT) angiography. Bovine configuration of the aortic arch and left carotid artery stenosis were easily identified by CT angiography and successfully treated through the right brachial approach technique. (orig.)

  3. Symptomatic intracranial vertebral artery atherosclerotic stenosis (≥70%) with concurrent contralateral vertebral atherosclerotic diseases in 88 patients treated with the intracranial stenting

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zi-Liang [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China); Gao, Bu-Lang [Department of Medical Research Shijiazhuang First Hospital, Hebei Medical University (China); Li, Tian-Xiao, E-mail: litianxiaod@163.com [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China); Cai, Dong-Yang; Zhu, Liang-Fu; Bai, Wei-Xing; Xue, Jiang-Yu; Li, Zhao-Shuo [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China)

    2015-09-15

    Highlights: • Symptomatic vertebral artery stenosis can be treated with intracranial stenting. • Stenting for intracranial vertebral artery stenosis is safe and effective. • Stenting for intracranial vertebral artery stenosis can prevent long-term stroke. - Abstract: Purpose: To investigate the safety, effect and instent restenosis rate of Wingspan stenting in treating patients with intracranial vertebral artery atherosclerotic stenosis (70–99%) concurrent with contralateral vertebral artery atherosclerotic diseases. Materials and methods: Eighty-eight patients with severe symptomatic intracranial vertebral artery atherosclerotic stenosis (≥70%) combined with contralateral vertebral artery atherosclerotic diseases were treated with the Wingpsan stent. All the baseline, cerebral angiography, success rate, perioperative complications, clinical and imaging follow-up data were prospectively analyzed. Results: The success rate of stenting was 100%, and the mean stenotic rate was reduced from prestenting (84.9 ± 6.8)% to poststenting (17.2 ± 5.9)%. The perioperative stroke rate was 1.1%. Among eighty patients (90.9%) with clinical follow-up 8-62 months (mean 29.3 ± 17.2) poststenting, five (6.3%) had posterior circulation TIA only, three (3.8%) had mild stroke in the posterior circulation but recovered completely, and another five patients greater than 70 years old died of non-ischemic stroke. Imaging follow-up in 46 patients (52.3%) 5–54 months (mean 9.9 ± 9.9) following stenting revealed instent restenosis in 12 patients (26.1%) including 7 (58.3%) symptomatic restenosis. Age and residual stenosis were the two factors to significantly (P < 0.05) affect instent restenosis. Conclusion: Wingspan stenting in the intracranial vertebral artery atherosclerotic stenosis combined with contralateral vertebral artery atherosclerotic diseases has a low perioperative stroke rate and a good preventive effect on long-term ischemic stroke, but the instent restenosis

  4. Evaluation of middle cerebral artery stents using multidetector row CT angiography in vivo study: comparison of the three different kernels

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin Hee; Lim, Yeon Soo; Lee, Youn Joo; Yoo, Won Jong; Sung, Mi Sook (Dept. of Radiology, Bucheon St Mary' s Hospital, Coll. of Medicine, The Catholic Univ. of Korea, Bucheon (Korea, Republic of)), email: wjyu@catholic.ac.kr; Kim, Bum Soo (Dept. of Radiology, Seoul St Mary' s Hospital, Coll. of Medicine, The Catholic Univ. of Korea, Seoul (Korea, Republic of))

    2012-05-15

    Background: There are very few reports assessing middle cerebral artery (MCA) stents using multidetector computed tomography (MDCT). Purpose: To assess MCA stents using multidetector CT angiography (CTA) in vivo evaluation: the differences in the CTA results according to the three different kernels. Material and Methods: We retrospectively evaluated 27 MCA stents from 26 patients who underwent CTA with 16- and 64-slice MDCT after percutaneous transluminal angioplasty and stenting (PTAS). By CTA, using medium-smooth kernel (B30), medium-sharp kernel (B50), and sharp kernel (B60), the lumen diameter, artificial luminal narrowing (ALN), and subjective visibility score of the stented vessels were evaluated. The subjective visibility score ranged from 1 (poor quality) to 5 (excellent) using a five-point scale. Results: There were excellent inter-observer agreements for the lumen diameter measurements (P < 0.001). The mean diameter of the stented vessels was 2.10 +- 0.31 mm on digital subtraction angiography (DSA), 0.93 +- 0.20 mm on CTA using B30, 1.18 +- 0.27 mm on CTA using B50, and 1.29 +- 0.29 mm on CTA using B60. The mean ALN was 55.7 +- 6.0% on CTA using B30, 43.8 +- 7.5% on CTA using B50, and 38.7 +- 8.3% on CTA using B60. CTA with higher kernels had a smaller ALN than images with smaller kernels. The median subjective visibility score on the CTA using B50 was 3, which was higher than for the other kernels. The differences in the lumen diameter, ALN, and the subjective visibility score of the stented vessels on CTA using the three different kernels was statistically significant (P < 0.001). Conclusion: The sharp kernel was better to assess the lumen diameter and ALN, but was inferior to the medium-sharp kernel for in-stent evaluation due to high image-to-noise. CTA with medium-sharp kernel showed good lumen visibility and acceptable ALN for MCA stents. This could therefore be a non-invasive, readily applicable clinical method for assessing MCA stent patency after

  5. Thoracic Stent Graft Implantation for Aortic Coarctation with Patent Ductus Arteriosus via Retroperitoneal Iliac Approach in the Presence of Small Sized Femoral Artery

    Directory of Open Access Journals (Sweden)

    Ozge Korkmaz

    2016-01-01

    Full Text Available Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach.

  6. Safety and efficacy of everolimus-eluting stents compared with first-generation drug-eluting stents in patients undergoing primary percutaneous coronary intervention

    Energy Technology Data Exchange (ETDEWEB)

    Escárcega, Ricardo O.; Baker, Nevin C.; Magalhaes, Marco A.; Lipinski, Michael J.; Minha, Sa’ar; Torguson, Rebecca; Satler, Lowell F.; Pichard, Augusto D.; Suddath, William O.; Waksman, Ron, E-mail: ron.waksman@medstar.net

    2014-09-15

    Objective: To assess the safety and efficacy everolimus-eluting stents (EES) compared with first-generation drug-eluting stents (DES) in patients with acute myocardial infarction (MI) undergoing primary percutaneous coronary intervention (PCI). Background: EES have been associated with improved clinical outcomes compared to paclitaxel-eluting stents (PES) and with similar outcomes compared to sirolimus-eluting stents (SES). Methods: A total of 520 patients who presented with ST-elevation myocardial infarction (STEMI) from 2003 to 2013, who underwent primary PCI with DES, were retrospectively analyzed. Of these, 247 received SES, 136 PES, and 137 EES. Patients were followed up to 2 years for major adverse cardiac events (MACE). Univariate and multivariate models detected correlates to outcome. Results: EES implantation, compared with PES and SES, resulted in comparable rates of MACE (8.8% vs. 16.2%, p = 0.06 and 8.8% vs. 12.6%, respectively, p = 0.26), stent thrombosis, MI, and target lesion revascularization. Patients who received EES had lower rates of all-cause mortality (3.7% vs. 12.6% vs. 9.4%, p = 0.03) at 1-year follow up. However, in the univariate and multivariate analyses, stent type was not independently associated with the primary outcome or with all-cause mortality. Diabetes mellitus and number of stents implanted were independently associated with the primary outcome. Conclusion: While EES seem to be associated with better outcome when compared to PES, the main correlates of STEMI patients are the presence of diabetes and number of stents implanted, and not the type of stent used for intervention.

  7. Placement of hemoparin-coated stents in the iliac arteries: Early experience and midterm results in 28 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kalmar, Peter I., E-mail: peter.kalmar@medunigraz.at; Portugaller, Rupert H., E-mail: rupert.portugaller@medunigraz.at; Schedlbauer, Peter, E-mail: peter.schedlbauer@klinikum-graz.at; Bohlsen, Dennis, E-mail: dennis.bohlsen@medunigraz.at; Deutschmann, Hannes A., E-mail: hannes.deutschmann@medunigraz.at

    2014-07-15

    Purpose: Aim was to determine immediate results and mid-term outcome of the hemoparin-coated (HC) stainless-steel stent (camouflage coating) in the treatment of occlusive lesions of the iliac arteries. Materials and methods: Twenty-eight patients were prospectively treated with the use of a HC stent between January 2007 and March 2010. Clinical examination and color-doppler ultrasound were performed at 1, 3, 6 and 12 months, CT angiography (CTA) or MR angiography (MRA) at 12 months. Indication for treatment was a high-grade stenosis of the common iliac and/or external iliac artery. Results: Successful placement was achieved in all patients. Significant decrease in translesional pressure gradient (>10 mmHg) was measured in 27 patients (96%). In one patient, proximal dissection occurred without flow limitation. A minor complication (small access site hematoma) occurred in one patient (4%). Two patients (7%) were lost to follow-up. After 12 months, stent patency in CTA, MRA and ultrasound was 100%. 20 patients (77%) experienced an initial improvement of at least one clinical stage. In one patient (4%), mild intimal hyperplasia without significant stenosis was observed. In three patients (12%), proximal or distal stenosis occurred. A non-significant increase of mean ankle-brachial index (ABI) after treatment was measured (0.85 ± 0.27 vs. 0.75 ± 0.22, respectively; p = 0.328). Conclusions: The use of HC stents in patients with iliac artery occlusive disease may lead to a lower rate of intimal hyperplasia and thus to increased patency rates even in heavily calcified vessels. However, large-scale prospective trials have to be performed to evaluate the long-term patency rates of the HC coated stents.

  8. The use of covered stents for the endovascular treatment of extracranial internal carotid artery stenosis: a prospective study with a 5-year follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Szolics, Alex; Szikra, Peter; Palko, Andras; Voeroes, Erika [University of Szeged, Department of Radiology, Szeged (Hungary); Sztriha, Laszlo K. [University of Szeged, Department of Neurology, Szeged (Hungary); Szolics, Miklos [Tawam Hospital in affiliation with Johns Hopkins Medicine, Division of Neurology, Al Ain, P.O. Box 15258, Abu Dhabi Emirate (United Arab Emirates)

    2010-07-15

    To evaluate the safety and feasibility of the use of covered stents for the treatment of extracranial carotid artery stenosis caused by highly embologenic plaques, and to study the long-term outcome of patients receiving such covered stents. Between 2002 and 2007, 46 patients (63% symptomatic, 78.3% male, 67 {+-} 8.6 years old) with internal carotid artery stenosis caused by embologenic plaques or restenosis were treated with self-expanding covered stents (Symbiot, Boston Scientific). Pre-dilatation or protecting devices were not used. Post-dilatation was applied in every patient. Each patient was followed long-term. The outcome measures were the occurrence of neurological events, and the development of in-stent restenosis, as detected by clinical examination and duplex ultrasound. The technical success rate of stenting was 100%. There were no neurological complications in the peri-procedural period. The mean follow-up period was 34.3 {+-} 27.7 months (the rate of patients lost to follow-up was 15.2%) during which no stroke or stroke-related deaths occurred. Restenosis was detected in 3 patients (6.5%). Covered stents provide efficient peri- and post-procedural protection against neurological complications due to embolisation from high-risk plaques during carotid artery stenting. Restenosis of covered stents appears to be infrequent during long-term follow-up. (orig.)

  9. In-Vitro Evaluation of Coronary Stents and 64-Detector-Row Computed Tomography Using a Newly Developed Model of Coronary Artery Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, T.; Scheuermann, T.; Ulzheimer, S.; Mohrs, O.K.; Kuehling, M.; Albrecht, P.E.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A. (Cardiovascular Center Bethanien (CCB), Frankfurt (DE))

    2008-02-15

    Background: Stent implantation is the predominant therapy for non-surgical myocardial revascularization in patients with coronary artery disease. However, despite substantial advances in multidetector computed tomography (MDCT) coronary imaging, a reliable detection of coronary in-stent restenosis is currently not possible. Purpose: To examine the ability of 64-detector-row CT to detect and to grade in-stent stenosis in coronary stents using a newly developed ex-vivo vessel phantom with a realistic CT density pattern, artificial stenosis, and a thorax phantom. Material and Methods: Four different stents (Liberte and Lunar ROX, Boston Scientific; Driver, Medtronic; Multi-Link Vision, Guidant) were examined. The stents were placed on a polymer tube with a diameter of 2.5, 3.0, 3.5, or 4.0 mm. Different degrees of stenosis (0%, 30%, 50%, 70-80%) were created inside the tube. For quantitative analysis, attenuation values were measured in the non-stenotic vessel outside the stent, in the non-stenotic vessel inside the stent, and in the stenotic area inside the stent. The grade of stenosis was visually assessed by two observers. Results: All stents led to artificial reduction of attenuation, the least degree of which was found in the Liberte stent (11.3+-10.2 HU) and the Multi-Link Vision stent (17.6+-17.9 HU; P 0.25). Overall, the non-stenotic vessel was correctly diagnosed in 55.5%, the low-grade stenosis in 58.3%, the intermediate stenosis in 63.8%, and the high-grade stenosis in 80.5%. In the 3.0-, 3.5-, and 4.0-mm vessels, in none of the cases was a non-stenotic or low-grade stenotic vessel misdiagnosed as intermediate or high-grade stenosis. The average deviation from the real grade of stenosis was 0.40 for the Liberte stent, 0.46 for the Lunar ROX stent, 0.45 for the Driver stent, and 0.58 for the Multi-Link Vision stent. Conclusion: Our ex-vivo data show that non-stenotic stents and low-grade in-stent stenosis can be reliably differentiated from intermediate and

  10. Prognostic Value of Plasma Pentraxin-3 Levels in Patients with Stable Coronary Artery Disease after Drug-Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Liu Haibo

    2014-01-01

    Full Text Available Pentraxin-3 (PTX3 is an inflammatory marker thought to be more specific to cardiovascular inflammation than C-reactive protein (CRP. Our aim was to assess the prognostic value of PTX3 in patients with stable coronary artery disease (CAD after drug eluting stent (DES implantation. Plasma PTX3 levels were measured before percutaneous coronary intervention (PCI and at 24 h post-PCI in 596 consecutive patients with stable CAD. Patients were followed up for a median of 3 years (range 1–5 for major adverse cardiovascular events (MACEs. We found that the post-PCI plasma PTX3 levels were significantly higher at 24 h after PCI than pre-PCI, patients with MACEs had higher post-PCI PTX3 levels compared with MACEs-free patients, patients with higher post-PCI PTX3 levels (median > 4.384 ng/mL had a higher risk for MACEs than those with PTX3 < 4.384 ng/mL, and post-PCI PTX3, cTnI, multiple stents, and age but not high-sensitivity CRP (hsCRP were independently associated with the prevalence of MACEs after DES implantation. The present study shows that post-PCI PTX3 may be a more reliable inflammatory predictor of long-term MACEs in patients with stable CAD undergoing DES implantation than CRP. Measurement of post-PCI PTX3 levels could provide a rationale for risk stratification of patients with stable CAD after DES implantation.

  11. A 16-year experience of carotid artery stenting for carotid artery stenosis.

    Science.gov (United States)

    Nano, Giovanni; Stegher, Silvia; Occhiuto, Maria Teresa; Muzzarelli, Lorenzo; Malacrida, Giovanni; Mazzaccaro, Daniela P

    2016-01-01

    Da più di 50 anni l’endoarteriectomia carotidea (CEA) è stata considerata il trattamento standard per le stenosi carotidee gravi asintomatiche e sintomatiche. Lo stenting carotideo (CAS) è progressivamente emerso negli ultimi 15 anni come alternativa alla chirurgia, specialmente nei pazienti ad alto rischio. Da allora, molti studi clinici randomizzati sono stati pubblicati per valutare la superiorità di un metodo rispetto all’altro, tuttavia i risultati dei trials hanno generato più dubbi che certezze nell’interpretazione dei loro risultati, gravati come sono da diverse limitazioni: la principale riguarda la ridotta competenza endovascolare richiesta per gli operatori che hanno eseguito lo stenting carotideo e partecipato ai trials. Inoltre questi trials sono stati eseguiti circa 10 anni fa, con materiali e farmaci differenti rispetto a quelli usati attualmente. Attualmente i registri su larga scala e le casistiche che riportano risultati a lungo termine sono maggiormente rappresentativi di una esperienza reale, che riflette ciò che accade di routine nella pratica clinica. Nella nostra Unità Operativa di Chirurgia Vascolare, il CAS è stato offerto dal 1999 come alternativa alla CEA per il trattamento delle stenosi carotidee sintomatiche e asintomatiche nei pazienti a rischio moderato-alto. Scopo del nostro lavoro è di riportare la nostra esperienza retrospettiva, con alcuni consigli e suggerimenti che derivano da ciò che abbiamo imparato in più di 16 anni. Abbiamo pertanto raccolto e analizzato retrospettivamente i dati di tutti i pazienti consecutivi che sono venuti per una stenosi carotidea significativa dal 1 ° gennaio 1999 al 31 agosto 2015. I risultati basilari sono stati la mortalità e la morbilità cerebrovascolare maggiore (MCE) sia a 30 giorni che a lungo termine. Lo studio è stato condotto su 1017 pazienti (677 maschi, 66.6%, età media 74 anni, IQR 69-79 anni) trattati sia per stenosi carotidea sintomatica (n=392, 38.5%) che

  12. Combined application of distal and proximal embolic protection devices in endovascular stenting for severe carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Zhi-hua DU

    2011-09-01

    Full Text Available Objective To analyze and summarize methods and experiences of combined application of distal and proximal embolic protection devices(EPD in endovascular stenting for severe carotid artery stenosis.Methods Five patients with severe stenosis of the common carotid artery or with extracranial segment of the internal carotid artery diagnosed through digital subtraction angiography(DSA from March to July 2010 were involved in the present study.All patients received carotid angioplasty and stenting(CAS,with a combination of distal and proximal EPD via the percutaneous femoral artery approach.Results The operation failed in one patient,whereas technical success with no intraoperative complication was achieved in four patients.The symptoms disappeared or improved in the four cases that achieved technical success.The follow-up duration was one to three months,and no cerebral ischemia was found.Conclusion CAS with the combined application of distal and proximal EPD in some special cases of carotid artery stenosis may surmount the shortage of single EPD,reduce the risk of intraoperative embolization,decrease the time of intraoperative endovascular inflow occlusion,and reduce high-risk operations.CAS may be used as an individualized treatment strategy for patients with carotid artery stenosis.

  13. Impact of cardiac rehabilitation on angiographic outcomes after drug-eluting stents in patients with de novo long coronary artery lesions.

    Science.gov (United States)

    Lee, Jong-Young; Yun, Sung-Cheol; Ahn, Jung-Min; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Lee, Cheol Whan; Park, Seong-Wook; Yoo, Yeong Sook; Park, Eun-Kyung; Jin, Young-Soo; Kim, Jeongsoon; Nam, Hyo-Jung; Min, Sun-Yang; Park, Seung-Jung

    2014-06-15

    Cardiac rehabilitation (CR) can reduce cardiovascular mortality and morbidity in coronary artery disease. Long coronary artery lesions may be associated with adverse outcomes after drug-eluting stent (DES) implantation. The purpose of this study was to evaluate angiographic outcomes after a comprehensive CR program in patients with DESs for long coronary artery lesions. A total of 576 patients treated with DESs for long (≥25 mm) coronary lesions were enrolled in this prospective CR registry. Comprehensive CR programs were successfully performed in 288 patients (50%). The primary end point was in-stent late luminal loss at the 9-month angiographic follow-up. There were few significant differences between the CR and non-CR groups in terms of baseline characteristics, including clinical, angiographic, and procedural variables. The rate of in-stent late luminal loss in the CR group was 35% less than in the usual care group (0.19 ± 0.33 mm in CR vs 0.29 ± 0.45 mm in non-CR, difference 0.08 mm, 95% confidence interval 0.01 to 0.16, p = 0.02) at the 9-month follow-up. After propensity-matched analysis (224 pairs), the results were consistent (0.18 ± 0.31 mm in CR vs 0.28 ± 0.41 mm in non-CR, difference 0.10 mm, 95% confidence interval 0.02 to 0.18, p = 0.02). The CR group showed a significant improvement in the overall risk profile compared with the non-CR group, including current smoking, biochemical profiles, depression, obesity, and exercise capacity. In conclusion, the comprehensive CR program significantly reduced late luminal loss after DES implantation for long coronary lesions. This may be associated with significant improvements in exercise capacity and overall risk profile.

  14. Impact of coexisting coronary artery disease on the occurrence of cerebral ischemic lesions after carotid stenting.

    Directory of Open Access Journals (Sweden)

    Kuo-Lun Huang

    Full Text Available BACKGROUND: Coronary artery disease (CAD may coexist with extracranial carotid artery stenosis (ECAS, but the influence of CAD on procedure-related complications after carotid artery stenting (CAS has not been well investigated. The study aimed to determine the impact of CAD on the occurrence of peri-CAS cerebral ischemic lesions on diffusion-weighted imaging (DWI scanning. METHODS: Coronary angiography was performed within six months before CAS. DWI scanning was repetitively done within 1 week before and after CAS. Clinical outcome measures were stroke, angina, myocardial infarction and death within 30 days. RESULTS: Among 126 patients (69.5±9.0 years recruited for unilateral protected CAS, 33 (26% patients had peri-CAS DWI-positive lesions. CAD was noted in 79% (26 in 33 and 48% (45 in 93 of patients with and without peri-CAS DWI-positive lesions (OR, 4.0; 95% CI, 1.6-10.0; P = .0018, and the number of concomitant CAD on coronary angiography was positively correlated with the risk for peri-CAS DWI-positive lesions (P = .0032. In patients with no CAD (n = 55, asymptomatic CAD (n = 41 and symptomatic CAD (n = 30, the occurrence rates of peri-CAS DWI-positive lesions were 13%, 41% and 30% (P = .0048, and the peri-CAS stroke rates were 2%, 7% and 0% (P = .2120. CONCLUSIONS: The severity of morphological CAD and the presence of either symptomatic or asymptomatic CAD are associated with the occurrence of peri-CAS cerebral ischemic lesions.

  15. Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice.

    Directory of Open Access Journals (Sweden)

    Sakine Simsekyilmaz

    Full Text Available Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG, and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE-/- carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches.

  16. Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice.

    Science.gov (United States)

    Simsekyilmaz, Sakine; Liehn, Elisa A; Weinandy, Stefan; Schreiber, Fabian; Megens, Remco T A; Theelen, Wendy; Smeets, Ralf; Jockenhövel, Stefan; Gries, Thomas; Möller, Martin; Klee, Doris; Weber, Christian; Zernecke, Alma

    2016-01-01

    Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal) were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs) and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE-/- carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches.

  17. Bypass surgery versus stenting for the treatment of multivessel disease in patients with unstable angina compared with stable angina

    OpenAIRE

    de Feyter, Pim; Heuvel, P.; Unger, Felix; Beyar, R; Lindeboom, Wietze; de Valk, Vincent; Milo, S; Simon, Rudiger; Tyers, Frank; Regensburger, D.; Crean, Peter; Penn, Ian; McGovern, E; Cauwelaert, C.; Serruys, Patrick

    2002-01-01

    textabstractBACKGROUND: Earlier reports have shown that the outcome of balloon angioplasty or bypass surgery in unstable angina is less favorable than in stable angina. Recent improvements in percutaneous treatment (stent implantation) and bypass surgery (arterial grafts) warrant reevaluation of the relative merits of either technique in treatment of unstable angina. Methods and Results- Seven hundred fifty-five patients with stable angina were randomly assigned to coronary stenting (374) or ...

  18. Randomized Comparison of the Crush Versus the Culotte Stenting for Coronary Artery Bifurcation Lesions

    Institute of Scientific and Technical Information of China (English)

    Xu-Wei Zheng; Dong-Hui Zhao; Hong-Yu Peng; Qian Fan; Qin Ma; Zhen-Ye Xu; Chao Fan

    2016-01-01

    Background:The crush and the culotte stenting were both reported to be effective for complex bifurcation lesion treatment.However,their comparative performance remains elusive.Methods:A total of 300 patients with coronary bifurcation lesions were randomly assigned to crush (n =150) and culotte (n =150) treatment.The primary endpoint was the occurrence of major adverse cardiac events (MACEs) at 12 months including cardiac death,myocardial infarction,stent thrombosis,and target vessel revascularization.Index lesion restenosis at 12 months was a secondary endpoint.The surface integrals of time-averaged wall shear stress at bifurcation sites were also be quantified.Results:There were no significant differences in MACE rates between the two groups at 12-month follow-up:Crush 6.7%,culotte 5.3% (P =0.48).The rates of index lesion restenosis were 12.7% versus 6.0% (P =0.047) in the crush and the culotte groups,respectively.At 12-month follow-up,the surface integrals of time-averaged wall shear stress at bifurcation sites in the crush group were significantly lower than the culotte group ([5.01 ± 0.95] × 10-4 Newton and [6.08 ± 1.16] × 10 4 Newton,respectively;P =0.003).Conclusions:Both the crush and the culotte bifurcation stenting techniques showed satisfying clinical and angiographic results at 12-month follow-up.Bifurcation lesions treated with the culotte technique tended to have lower restenosis rates and more favorable flow patterns.

  19. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available OBJECTIVE: To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system. METHODS: Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications. RESULTS: The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed. CONCLUSION: Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  20. Evaluation of changes of intracranial blood flow after carotid artery stenting using digital subtraction angiography flow assessment

    Institute of Scientific and Technical Information of China (English)

    Hajime; Wada; Masato; Saito; Kyousuke; Kamada

    2015-01-01

    AIM: To evaluate the changes of intracranial blood flow after carotid artery stenting(CAS), using the flow assessment application "Flow-Insight", which was developed in our department.METHODS: Twenty patients treated by CAS participated in this study. We analyzed the change in concentration of the contrast media at the anterior-posterior and profile view image with the flow assessment application "Flow-Insight". And we compared the results with N-isopropyl-p-[123I] iodoamphetamine-single-photon emission computed tomography(IMP SPECT) performed before and after the treatment. RESULTS: From this study, 200% of the parameter "blood flow" change in the post/pre-treatment is suggested as the critical line of the hyperperfusion syndrome arise. Although the observed blood flow increase in the digital subtraction angiography system did not strongly correlate with the rate of increase of SPECT, the "Flow-Insight" reflected the rate of change of the vessels well. However, for patients with reduced reserve blood flow before CAS, a highly elevated site was in agreement with the site analysis results. CONCLUSION: We concluded that the cerebral angiography flow assessment application was able to more finely reveal hyperperfusion regions in the brain after CAS compared to SPECT.

  1. Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study

    Directory of Open Access Journals (Sweden)

    Brown Martin M

    2009-07-01

    Full Text Available Abstract Background Carotid angioplasty with stenting is a relatively new, increasingly used, less-invasive treatment for the treatment of symptomatic carotid artery stenosis. It is being evaluated in ongoing and nearly finished randomized trials. An important factor in the evaluation of stents is the occurrence of in-stent restenosis. An un-stented carotid artery is likely to have a more elastic vessel wall than a stented one, even if stenosis is present. Therefore, duplex ultrasound cut-off criteria for the degrees of an in-stent stenosis, based on blood velocity parameters, are probably different from the established cut-offs used for un-stented arteries. Routine criteria can not be applied to stented arteries but new criteria need to be established for this particular purpose. Methods/Design Current literature was systematically reviewed. From the selected studies, the following data were extracted: publication year, population size, whether the study was prospective, duplex ultrasound cut-off criteria reported, which reference test was used, and if there was an indication for selection bias and for verification bias in particular. Previous studies often were retrospective, or the reference test (DSA or CTA was carried out only when a patient was suspected of having restenosis at DUS, which may result in verification bias. Results In general, the velocity cut-off values for stenosis measurements in stented arteries were higher than those reported for unstented arteries. Previous studies often were retrospective, or the reference test (DSA or CTA was carried out only when a patient was suspected of having restenosis at DUS, which may result in verification bias. Discussion To address the deficiencies of the existing studies, we propose a prospective cohort study nested within the International Carotid Stenting Study (ICSS, an international multi-centre trial in which over 1,700 patients have been randomised between stenting and CEA. In this

  2. Influence of Simvastatin for In-stent Restenosis Rate and Blood Lipid Level and Inflammation Actor after Coronary Artery Stent Implantation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    To investigate the effect of simvastatin on the probability of restenosis after stent implantation and serum level of lipids as well as high-sensitivity C-reactive protein (hs-CRP) in patients with coronary heart disease (CHD).Methods 118 patients with CHD after stenting therapy were divided into treatment group (n = 62) and control group(n =56) randomly. All patients were treated withaspirin (100 mg/d) and clopidogrel (75 mg/d) while treatment group patients took simvastatin (40 mg qn) additionally. All patients underwent coronary angiography (CAG) to compare the difference of restenosis and the serum level of total cholesterol (TC), low-density lipoprotein cholesterol(LDL-c), high-density lipoprotein cholesterol (HDL-c), triglyceride (TG) as well as hs-CRP after the drug treatment for 6 months. Results The probability of restenosis was significantly lower in the treatment group than that of control group ( P < 0.01 ) and the results were similar between the patients with bare metal stent ( P < 0.01 ) and those with sirolimus-eluting stent ( P<0.01 ). The serum levels of TC (P<0.01 ), LDL-c( P<0.01 ), TG (P<0.05 ) and hsCRP (P<0.01) were obviously lower while the HDL-c (P<0.05 ) level was higher in the treatment group than those of control group. There was no death case. Conclusions Simvastatin could decrease the probability of restenosis significantly after coronary stent implantation with dose of 40 mg/d. It also has good performance on lipids control and lightening inflammatory reactions with its undoubtedly safety.

  3. Local sustained delivery of acetylsalicylic acid via hybrid stent with biodegradable nanofibers reduces adhesion of blood cells and promotes reendothelialization of the denuded artery.

    Science.gov (United States)

    Lee, Cheng-Hung; Lin, Yu-Huang; Chang, Shang-Hung; Tai, Chun-Der; Liu, Shih-Jung; Chu, Yen; Wang, Chao-Jan; Hsu, Ming-Yi; Chang, Hung; Chang, Gwo-Jyh; Hung, Kuo-Chun; Hsieh, Ming-Jer; Lin, Fen-Chiung; Hsieh, I-Chang; Wen, Ming-Shien; Huang, Yenlin

    2014-01-01

    Incomplete endothelialization, blood cell adhesion to vascular stents, and inflammation of arteries can result in acute stent thromboses. The systemic administration of acetylsalicylic acid decreases endothelial dysfunction, potentially reducing thrombus, enhancing vasodilatation, and inhibiting the progression of atherosclerosis; but, this is weakened by upper gastrointestinal bleeding. This study proposes a hybrid stent with biodegradable nanofibers, for the local, sustained delivery of acetylsalicylic acid to injured artery walls. Biodegradable nanofibers are prepared by first dissolving poly(D,L)-lactide-co-glycolide and acetylsalicylic acid in 1,1,1,3,3,3-hexafluoro-2-propanol. The solution is then electrospun into nanofibrous tubes, which are then mounted onto commercially available bare-metal stents. In vitro release rates of pharmaceuticals from nanofibers are characterized using an elution method, and a highperformance liquid chromatography assay. The experimental results suggest that biodegradable nanofibers release high concentrations of acetylsalicylic acid for three weeks. The in vivo efficacy of local delivery of acetylsalicylic acid in reducing platelet and monocyte adhesion, and the minimum tissue inflammatory reaction caused by the hybrid stents in treating denuded rabbit arteries, are documented. The proposed hybrid stent, with biodegradable acetylsalicylic acid-loaded nanofibers, substantially contributed to local, sustained delivery of drugs to promote re-endothelialization and reduce thrombogenicity in the injured artery. The stents may have potential applications in the local delivery of cardiovascular drugs. Furthermore, the use of hybrid stents with acetylsalicylic acid-loaded nanofibers that have high drug loadings may provide insight into the treatment of patients with high risk of acute stent thromboses.

  4. Five-Year Long-Term Clinical Follow-Up of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de novo Coronary Artery Lesions: The SPIRIT FIRST Trial

    NARCIS (Netherlands)

    M. Wiemer; P.W. Serruys; K. Miquel-Hebert; F.J. Neumann; J.J. Piek; E. Grube; J. Haase; L. Thuesen; C. Hamm

    2010-01-01

    Background: Drug-eluting stents have shown to be superior over bare metal stents in clinical and angiographic outcomes after percutaneous treatment of coronary artery stenosis. However, long-term follow-up data are scarce and only available for sirolimus- and paclitaxel-eluting stents. Aim: To asses

  5. Local Delivery of C-myc Antisense Oligodeoxynucleotide by Gelatin Coated Platinium-Iridium Stent to Prevent Restenosis in a Normal Rabbit Carotid Artery

    Institute of Scientific and Technical Information of China (English)

    Zhang Xinxia; Wei Wenbin; Duan Wen; Xu Xiangguang; Hu Xuesong

    2005-01-01

    Objectives To investigate the feasibility and effect of local deliveryof c-myc antisense oligodeoxynucleotide (ASODN) by gelatin coated Platinium-Iridium stent to prevent restenosis in a normal rabbit carotid artery. Methods Gelatin coated Platinium-Iridium stent were implanted in the right carotid arteries of 32 rabbits under vision. Animals were randomized to the control group and the treated group receiving c-myc ASODN (n=16 respectively).7,14,30,90 days following the stenting procedure,morphometry for caculation of neointimal area and mean neointimal thickness were performed.The expression of c-myc protein was detected by immunohistochemical methods. Results 32 stents were successfully implanted into the right carotid arteries in 32 animals. Morphometric analysis showed that neointimal area and mean neointimal thickness siginificantly increased continuously up to 12 weeks after stent implantation,and at each time point ,neointimal area and mean neointimal thickness were siginificantly smaller in the treated group than control group. (P<0.001 ,respectively).c-myc protein expression was weak positive or negative in treated group and positive in control group. Conclusions Gelatin coated Platinium-Iridium stent mediated local delivery of c-myc ASODN is feasibility , and it can inhibit neointimal hyperplasia to prevent restenosis in a normal rabbit carotid artery.

  6. Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT.

    Science.gov (United States)

    Maintz, David; Burg, Matthias C; Seifarth, Harald; Bunck, Alexander C; Ozgün, Murat; Fischbach, Roman; Jürgens, Kai Uwe; Heindel, Walter

    2009-01-01

    The aim of this study was to test a large sample of the latest coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in dual-source multidetector row CT (DSCT) in vitro and to provide a CT catalogue of currently used coronary artery stents. Twenty-nine different coronary artery stents (19 steel, 6 cobalt-chromium, 2 tantalum, 1 iron, 1 magnesium) were examined in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70 HU). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 400 mAs, 120 kV, rotation time 0.33 s. Image reconstructions were obtained with four different convolution kernels (soft, medium-soft, standard high-resolution, stent-dedicated). To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density, and noise were measured. The stent-dedicated kernel offered best average lumen visualization (54 +/- 8.3%) and most realistic lumen attenuation (222 +/- 44 HU) at the expense of increased noise (23.9 +/- 1.9 HU) compared with standard CTA protocols (p magnesium stent showed the least artifacts with a lumen visibility of 90%. The majority of stents (79%) exhibited a lumen visibility of 50-59%. Less than half of the stent lumen was visible in only six stents. Stent lumen visibility largely varies depending on the stent type. Magnesium is by far more favorable a stent material with regard to CT imaging when compared with the more common materials steel, cobalt-chromium, or tantalum. The magnesium stent exhibits a lumen visibility of 90%, whereas the majority of the other stents exhibit a lumen visibility of 50-59%.

  7. Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Maintz, David; Burg, Matthias C.; Seifarth, Harald; Bunck, Alexander C.; Oezguen, Murat; Juergens, Kai Uwe; Heindel, Walter [University of Muenster, Department of Clinical Radiology, Muenster (Germany); Fischbach, Roman [University of Muenster, Department of Clinical Radiology, Muenster (Germany); Asklepios Klinikum Altona, Department of Radiology and Nuclear Medicine, Hamburg (Germany)

    2009-01-15

    The aim of this study was to test a large sample of the latest coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in dual-source multidetector row CT (DSCT) in vitro and to provide a CT catalogue of currently used coronary artery stents. Twenty-nine different coronary artery stents (19 steel, 6 cobalt-chromium, 2 tantalum, 1 iron, 1 magnesium) were examined in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70 HU). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 400 mAs, 120 kV, rotation time 0.33 s. Image reconstructions were obtained with four different convolution kernels (soft, medium-soft, standard high-resolution, stent-dedicated). To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density, and noise were measured. The stent-dedicated kernel offered best average lumen visualization (54{+-}8.3%) and most realistic lumen attenuation (222{+-}44 HU) at the expense of increased noise (23.9{+-}1.9 HU) compared with standard CTA protocols (p<0.001 for all). The magnesium stent showed the least artifacts with a lumen visibility of 90%. The majority of stents (79%) exhibited a lumen visibility of 50-59%. Less than half of the stent lumen was visible in only six stents. Stent lumen visibility largely varies depending on the stent type. Magnesium is by far more favorable a stent material with regard to CT imaging when compared with the more common materials steel, cobalt-chromium, or tantalum. The magnesium stent exhibits a lumen visibility of 90%, whereas the majority of the other stents exhibit a lumen visibility of 50-59%. (orig.)

  8. The 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE trial: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Park Kyung

    2012-03-01

    Full Text Available Abstract Background Second-generation drug-eluting stents (DES have raised the bar of clinical performance. These stents are mostly made from cobalt chromium alloy. A newer generation DES has been developed from platinum chromium alloy, but clinical data regarding the efficacy and safety of the platinum chromium-based everolimus-eluting stent (PtCr-EES is limited, with no comparison data against the cobalt chromium-based zotarolimus-eluting stent (CoCr-ZES. In addition, an antiplatelet regimen is an integral component of medical therapy after percutaneous coronary intervention (PCI. A 1-week duration of doubling the dose of clopidogrel (double-dose antiplatelet therapy (DDAT was shown to improve outcome at 1 month compared with conventional dose in acute coronary syndrome (ACS patients undergoing PCI. However in Asia, including Korea, the addition of cilostazol (triplet antiplatelet therapy (TAT is used more commonly than doubling the dose of clopidogrel in high-risk patients. Methods In the 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE trial, approximately 3,750 patients are being prospectively and randomly assigned in a 2 × 2 factorial design according to the type of stent (PtCr-EES vs CoCr-ZES and antiplatelet regimen (TAT vs DDAT. The first primary endpoint is target lesion failure at 1 year for the stent comparison, and the second primary endpoint is net clinical outcome at 1 month for comparison of antiplatelet therapy regimen. Discussion The HOST-ASSURE trial is the largest study yet performed to directly compare the efficacy and safety of the PtCr-EES versus CoCr-ZES in an 'all-comers' population. In addition, this study will also compare the clinical outcome of TAT versus DDAT for 1-month post PCI. Trial registration ClincalTrials.gov number NCT01267734.

  9. Everolimus-eluting stent platforms in percutaneous coronary intervention: comparative effectiveness and outcomes

    Directory of Open Access Journals (Sweden)

    Panoulas VF

    2015-07-01

    Full Text Available Vasileios F Panoulas,1 Ioannis Mastoris,2 Klio Konstantinou,1 Maurizio Tespili,3 Alfonso Ielasi3 1National Heart and Lung Institute, Imperial College London, London, UK; 2Interventional Cardiovascular Research and Clinical Trials, The Zena and Michael A Wiener Cardiovascular Institute, The Icahn School of Medicine at Mount Sinai, New York NY, USA; 3Cardiology Department, Bolognini Hospital Seriate, Seriate (BG, Italy Abstract: Despite the remarkable benefits obtained following the introduction of the first-generation drug-eluting stent (DES, concerns were raised over its long-term safety, particularly with regard to very late (beyond 1 year stent thrombosis. Newer-generation DESs have been developed to overcome this limitation using novel stent platforms, new drugs, more biocompatible durable polymers, and bioabsorbable polymers or backbones. To date, new-generation DESs have virtually replaced the use of first-generation DESs worldwide. In this review article, we discuss in detail the design, pharmacology, and mechanism of action of the newer-generation permanent and bioresorbable everolimus-eluting platforms. Furthermore, we present and evaluate the current evidence on the performance and safety of these devices compared to those of other available stent platforms. Keywords: PCI, angioplasty, stent, outcome 

  10. Neoatherosclerosis in the stent

    Directory of Open Access Journals (Sweden)

    A. A. Komkov

    2015-01-01

    Full Text Available Achievements of interventional cardiology in the treatment of coronary artery disease are based on coronary balloon angioplasty with implanting bare metal stents and drug eluting stents. Questions of complications such as early stent thrombosis and restenosis of stent were solved in a considerable degree. However, with the lengthening of the followup period, the problem of late complications became obvious. Except endothelization and fibromuscular proliferation in stented coronary arteries the process of plaque formation has an important influence on later complications in follow-up period more than one year. This process was defined as neoatherosclerosis. This is verified by clinical manifestations of the disease, histological studies, angioscopy, intravascular ultrasound and optical-coherence tomography in stented patients. Dynamic observation of the condition in stentedcoronary arteries showed multistep proliferation with restenosis, its regression, and neoatherosclerosis development. Evidences of neoatherosclerosis formation in stented coronary arteries are considered in this review.

  11. Treatment of symptomatic complex posterior circulation cerebral artery stenosis with balloon-mounted stents: technique feasibility and outcome

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Bin; Li, Gui-lin; Wang, Ren-zhi [Chinese Academy of Medical Science and Peking Union Medical College, Department of Neurosurgery, Peking Union Medical College Hospital, Beijing (China); Miao, Zhong-rong; Ji, Xun-min; Jiao, Li-qun; Ling, Feng [Capital University of Medical Science, Department of Neurosurgery, XuanWu Hospital, Beijing (China); Hua, Yang [Capital University of Medical Science, Department of Vascular Ultrasonography, XuanWu Hospital, Beijing (China)

    2009-05-15

    This study aimed to retrospectively analyze a series of patients with complex posterior circulation stenosis who underwent stent-assisted angioplasty to evaluate the feasibility of the procedure and summarize the experience with regard to complications. A total of 16 consecutive patients with 27 complex posterior circulation artery stenoses refractory to medical therapy were enrolled. Technical success rate, periprocedural complication, and long-term follow-up result were evaluated. The study population included 16 patients with 27 lesions. A total of 36 stents were successfully implanted. The technical success rate was 100%, and the overall periprocedural complication rate was 12.5% (2/16). During a median of 25.5 months of follow-up, three patients presented recurrent transient ischemic attacks, which were confirmed had restenosis more than 50% by control angiography or transcranial Doppler. Stent-assisted angioplasty is a feasible treatment method for complex posterior circulation artery stenosis. However, it appears to be associated with a relatively high periprocedural complication rate. Therefore, strict periprocedural management to reduce mortality and morbidity is needed. (orig.)

  12. Fabrication and in vitro deployment of a laser-activated shape memory polymer vascular stent

    Directory of Open Access Journals (Sweden)

    Matthews Dennis L

    2007-11-01

    Full Text Available Abstract Background Vascular stents are small tubular scaffolds used in the treatment of arterial stenosis (narrowing of the vessel. Most vascular stents are metallic and are deployed either by balloon expansion or by self-expansion. A shape memory polymer (SMP stent may enhance flexibility, compliance, and drug elution compared to its current metallic counterparts. The purpose of this study was to describe the fabrication of a laser-activated SMP stent and demonstrate photothermal expansion of the stent in an in vitro artery model. Methods A novel SMP stent was fabricated from thermoplastic polyurethane. A solid SMP tube formed by dip coating a stainless steel pin was laser-etched to create the mesh pattern of the finished stent. The stent was crimped over a fiber-optic cylindrical light diffuser coupled to an infrared diode laser. Photothermal actuation of the stent was performed in a water-filled mock artery. Results At a physiological flow rate, the stent did not fully expand at the maximum laser power (8.6 W due to convective cooling. However, under zero flow, simulating the technique of endovascular flow occlusion, complete laser actuation was achieved in the mock artery at a laser power of ~8 W. Conclusion We have shown the design and fabrication of an SMP stent and a means of light delivery for photothermal actuation. Though further studies are required to optimize the device and assess thermal tissue damage, photothermal actuation of the SMP stent was demonstrated.

  13. Fabrication and In Vitro Deployment of a Laser-Activated Shape Memory Polymer Vascular Stent

    Energy Technology Data Exchange (ETDEWEB)

    Baer, G M; Small IV, W; Wilson, T S; Benett, W J; Matthews, D L; Hartman, J; Maitland, D J

    2007-04-25

    Vascular stents are small tubular scaffolds used in the treatment of arterial stenosis (narrowing of the vessel). Most vascular stents are metallic and are deployed either by balloon expansion or by self-expansion. A shape memory polymer (SMP) stent may enhance flexibility, compliance, and drug elution compared to its current metallic counterparts. The purpose of this study was to describe the fabrication of a laser-activated SMP stent and demonstrate photothermal expansion of the stent in an in vitro artery model. A novel SMP stent was fabricated from thermoplastic polyurethane. A solid SMP tube formed by dip coating a stainless steel pin was laser-etched to create the mesh pattern of the finished stent. The stent was crimped over a fiber-optic cylindrical light diffuser coupled to an infrared diode laser. Photothermal actuation of the stent was performed in a water-filled mock artery. At a physiological flow rate, the stent did not fully expand at the maximum laser power (8.6 W) due to convective cooling. However, under zero flow, simulating the technique of endovascular flow occlusion, complete laser actuation was achieved in the mock artery at a laser power of {approx}8 W. We have shown the design and fabrication of an SMP stent and a means of light delivery for photothermal actuation. Though further studies are required to optimize the device and assess thermal tissue damage, photothermal actuation of the SMP stent was demonstrated.

  14. Temporary arterial stenting in a full-house spaghetti wrist injury in a remote rural setting: benefit for hand perfusion or risk of increased morbidity?

    Science.gov (United States)

    Bauer, Stefan; Savundra, James

    2013-01-01

    We report a case of temporary arterial plastic tube stenting of the ulnar and radial artery in a complete spaghetti wrist injury in a remote rural setting. Exploration in a specialist centre 18 h postinjury revealed that the tubes were clotted off with adjacent thrombi but hand perfusion was maintained. Intimal damage required vein grafting of both arteries 24 h postinjury. Hand perfusion was not compromised at follow-up. This case highlights that arterial hand perfusion can be maintained without the ulnar and radial artery. Arterial manipulation and tube insertion outside a specialist centre bears the risk of increased morbidity and potential microembolism and must therefore not be attempted.

  15. Efficacy comparison of the treatment of vertebral artery ostium and intracranial vertebral artery stenosis with Apollo stents%Apollo支架治疗椎动脉起始部和颅内段狭窄的疗效比较

    Institute of Scientific and Technical Information of China (English)

    李立; 李天晓; 薛绛宇; 朱良付; 王子亮; 白卫星; 赵同源; 李钊硕; 许岗勤

    2012-01-01

    目的 比较Apollo支架治疗椎动脉起始部和颅内段狭窄的安全性和有效性.方法 回顾性分析河南省人民医院介入科2010年1月-2011年12月使用Apollo支架治疗椎动脉单发狭窄103例患者的资料,共103处狭窄,根据狭窄部位分为椎动脉起始部组(33例)和椎动脉颅内段组(70例).比较两组患者的临床预后、再狭窄率及并发症.结果 ①支架到位率为100%.术后即刻造影显示,残余狭窄率<10%的有86处,其余16处的残余狭窄率均<20%,1处因出血用弹簧圈闭塞.② 有3例在围手术期出现并发症,占2.9%(3/103),其中1例并发脑出血,2例并发脑梗死,均为椎动脉颅内段组患者.椎动脉起始部组并发症的发生率(0/33)与颅内段组(3/70)比较,差异无统计学意义,P=0.549.③术后6个月影像学随访67例,其中13例发生支架内再狭窄,椎动脉起始部组再狭窄的发生率(32.1%,9/28)高于颅内段组(10.3%,4/39),差异有统计学意义,P=0.025.④术后临床随访 94例,平均9个月,无死亡病例.有8例再次发生后循环脑梗死,其中椎动脉起始部组3例(3/30,10.0%),颅内段组5例(5/64,7.8%),两组比较差异无统计学意义.结论 Apollo支架治疗椎动脉狭窄是安全、有效的.椎动脉颅内段组围手术期并发症的发生率高于起始部组,而椎动脉起始部组再狭窄的发生率高于颅内段组.%Objective To compare the safety and efficacy of Apollo stents in the treatment of vertebral artery ostium and intracranial vertebral artery stenosis. Methods A total of 103 patients with single vertebral artery stenosis treated with Apollo stents at the department of interventional radiology, Henan Provincial Peoples Hospital from January 2010 to December 2011 were analyzed retrospectively. The patients were divided into either a vertebral artery ostium group (n = 33) and an intracranial vertebral artery group ( n =70) according to the sites of stenosis. The clinical prognosis, in-stent

  16. Análise morfométrica da carótida de suínos submetidos a angioplastia com ou sem implante de stent de cromo-cobalto Morphometric analysis of swine carotid artery angioplasty with or without cobalt-chromium stent implantation

    Directory of Open Access Journals (Sweden)

    João Luiz de Lara Elesbão

    2010-06-01

    test. A p value of < 0.05 was considered significant. Results: Angioplasty with cobalt-chromium stent implantation resulted in a higher degree of hyperplasia compared with simple angioplasty. The difference was statistically significant when the lumen area, the internal elastic lamina area, and the external elastic lamina area were compared between the two groups. No statistically significant difference was found when the media layers of both groups were compared. Conclusion: Cobalt-chromium stent implantation resulted in more intimal hyperplasia than simple angioplasty, however the stent was not enough to reduce the arterial lumen.

  17. The Relationship Between Lymphocyte-to-Monocyte Ratio and Bare-Metal Stent In-Stent Restenosis in Patients With Stable Coronary Artery Disease.

    Science.gov (United States)

    Murat, Sani Namik; Yarlioglues, Mikail; Celik, Ibrahim Etem; Kurtul, Alparslan; Duran, Mustafa; Kilic, Alparslan; Oksuz, Fatih

    2017-04-01

    In-stent restenosis (ISR) is a common clinical problem in patients with coronary artery disease treated with percutaneous coronary intervention. Inflammatory process plays a pivotal role in the development of ISR. Both lymphocytes and monocytes are associated with inflammatory status. Recently, it has been shown that the lymphocyte-to-monocyte ratio (LMR) is a novel inflammatory marker. We aimed to investigate the association of serum LMR levels and ISR in patients undergoing bare-metal stent (BMS) implantation. The study included 273 patients (aged 61 ± 11 years, 66.5% men) with a history of BMS implantation and a further control coronary angiography due to stable angina pectoris. Patients were divided into 2 groups: patients with and without ISR. The LMR levels were significantly lower in patients with ISR than in those without ISR (2.50 ± 0.95 vs 3.87 ± 1.51, respectively, P ISR (odds ratio [OR]: 0.310, 95% confidence interval: 0.166-0.579, P ISR in patients treated with BMS implantation.

  18. Subclavian artery pseudoaneurysm complicating central venous catheterization: endovascular treatment with Amplatzer Vascular Plug 4 and covered stent.

    Science.gov (United States)

    Rossi, Umberto G; Petrocelli, Francesco; Ferro, Carlo

    2013-12-01

    Central venous catheterization is a routine vascular access procedure; however, it may be associated with life-threatening complications such as arterial puncture, leading to pseudoaneurysm formation. We report a case of a 41-year-old female that developed an iatrogenic left subclavian pseudoaneurysm complicating the attempt of left internal jugular vein cannulation for temporary hemodialysis therapy. The patient underwent urgent endovascular treatment with deployment of covered stent into the left subclavian artery (SCA) after embolization of the origin of the left internal mammary artery with Amplatzer Vascular Plug 4. The patient's recovery was unremarkable. Follow-up till 24 months reveals total exclusion of the pseudoaneurysm of the left SCA with patency of the distal branches.

  19. Arterial stenting with self-expandable and balloon-expandable endoprostheses

    NARCIS (Netherlands)

    W.J. van der Giessen (Wim); P.W.J.C. Serruys (Patrick); L.J. van Woerkens (L.); K.J. Beatt (Kevin); W.J. Visser (W.); J.F. Jongkind; R.H. van Bremen (Robert); E. Ridderhof; H. van Loon (Heleen); L.K. Soei (Lou Kie); H.M.M. van Beusekom (Heleen); P.D. Verdouw (Pieter)

    1990-01-01

    textabstractCoronary angioplasty is complicated by acute occlusion (within 24 hours) and late restenosis (within 6 months) in 2-5% and 20-40% of the cases, respectively. Vascular endoprostheses (stents) may provide the cardiologist with a solution to some of these complications. Several stent-device

  20. Treatment of popliteal artery aneurysms with the Hemobahn stent-graft

    NARCIS (Netherlands)

    Tielliu, IFJ; Verhoeven, ELG; Prins, TR; Post, WJ; Hulsebos, RG; van den Dungen, JJAM

    2003-01-01

    Purpose: To report a prospective study to ascertain the results of popliteal aneurysm treatment with a self-expanding stent-graft. Methods: In a recent 3-year period, 21 patients (18 men; median age 67 years, range 5282) with 23 popliteal aneurysms were treated with Hemobahn stent-grafts. Follow-up

  1. Prevention of restenosis in coronary arteries: ionic radiation, non-ionic radiation and drug eluting stents

    NARCIS (Netherlands)

    E.S. Regar (Eveline)

    2002-01-01

    textabstractOver the last decade, coronary stents have revolutionized the field of interventional cardiology. Stent implantation has become the new standard angioplasty procedure1-3. This popularity has grown because of 2 main reasons: first, the unique capability to master a major complication of b

  2. Carotid artery stenting: a single-centre experience with up to 8 years' follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Simonetti, Giovanni; Gandini, Roberto; Pampana, Enrico; Fabiano, Sebastiano; Stefanini, Matteo; Spinelli, Alessio; Reale, Carlo Andrea; Di Primio, Massimiliano; Gaspari, Eleonora [University Hospital ' ' Tor Vergata' ' , Department of Diagnostic Imaging, Molecular Imaging, Interventional Radiology and Radiation Therapy, Rome (Italy); Versaci, Francesco [University Hospital ' ' Tor Vergata' ' , Department of Internal Medicine, Unit of Cardiology, Rome (Italy)

    2009-04-15

    Carotid artery stenting (CAS) may be an alternative to surgical endoarterectomy not only in high-risk patients. We report results in the endovascular treatment of carotid artery disease with up to 8 years' follow-up. In this retrospective study, we analysed data from 853 consecutive patients (946 arteries) treated for carotid artery stenosis between April 1999 and March 2007; 491 (52%) arteries were symptomatic and 455(48%) were asymptomatic. Preprocedural evaluation of the patients was performed with echo Doppler, magnetic resonance angiography (MRA) or computed tomographic angiography (CTA) and a neurological examination. A cerebral protection device was used in 879 (92.9%) procedures. Anti-platelet therapy was administered before and after the procedure. All patients were included in a follow-up of up to 8 years. Technical success was achieved in 943 (99.6%) lesions. At 30 days, there was a 0.21% (n = 2) death rate, a 0.42% major stroke rate, a 1.69% minor stroke/transient ischaemic attack (TIA) rate and a combined 2.32% TIA/stroke and death rate. During follow-up, echo Doppler evidenced restenosis in 39 (4.85%) cases; of these, only five, presenting restenosis >80%, were treated with an endovascular reintervention. At the long-term follow-up, two strokes (0.23%) were reported, which both occurred within the first 2 years. In our experience, carotid artery stenting seems to be a safe and effective treatment, providing satisfactory long-term clinical results. (orig.)

  3. Endovascular treatment with angioplasty or stenting versus endarterectomy in patients with carotid artery stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2009-10-01

    Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS).

  4. Prediction of cerebral hyperperfusion syndrome after carotid artery stenting by CT perfusion imaging with acetazolamide challenge

    Energy Technology Data Exchange (ETDEWEB)

    Yoshie, Tomohide; Ueda, Toshihiro; Takada, Tatsuro; Nogoshi, Shinji; Fukano, Takayuki [St. Marianna University Toyoko Hospital, Department of Strokology, Stroke Center, Kawasaki (Japan); Hasegawa, Yasuhiro [St. Marianna University School of Medicine, Department of Internal Medicine, Division of Neurology, Kawasaki (Japan)

    2016-03-15

    Cerebral hyperperfusion syndrome (HPS) is an uncommon but serious complication of carotid artery stenting (CAS). The purpose of this study was to investigate the efficacy of CT perfusion imaging (CTP) with acetazolamide challenge to identify patients at risk for HPS after CAS. We retrospectively analyzed 113 patients who underwent CTP with rest and acetazolamide challenge before CAS. CTP maps were assessed for absolute and relative cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), and change of each parameter before and after acetazolamide challenge. Patients were divided into two groups according to the HPS after the CAS. Receiver-operating characteristic (ROC) curve analysis was performed to determine the most accurate CTP parameter for the prediction of HPS. Nine of 113 patients had HPS. There were significant differences for absolute and relative values of resting CBF (p = 0.001 and p = 0.026), resting MTT (p < 0.001 and p = 0.004), post-acetazolamide CBF (p < 0.001 and p = 0.001), post-acetazolamide MTT (p < 0.001 and p = 0.002), and %changes of CBF (p = 0.009) between the HPS and non-HPS groups. ROC curve analysis showed that the CTP parameters with the maximal area under the receiver-operating characteristic curve (AUC) for HPS was the absolute value of post-acetazolamide MTT (AUC 0.909) and the absolute value of resting MTT (AUC 0.896). Pretreatment CTP with acetazolamide challenge could identify patients at risk for HPS after CAS. Although the CTP parameter that most accurately identified patients at risk for HPS was the absolute value of post-acetazolamide MTT, resting MTT was sufficiently accurate. (orig.)

  5. Application of rotational DSA dual volume technology in the displaying of intracranial artery stent and its effective analysis%颅内动脉支架的旋转DSA双容积显示方法及效果分析

    Institute of Scientific and Technical Information of China (English)

    沈正林; 胡克琦; 闻宏斌; 李秀荣; 常丽英

    2016-01-01

    合显示技术能较好地表现血管内的支架情况。%Objective To investigate the implementation and application of rotational DSA dual volume technology in displaying the intracranial artery stent.Methods Firstly,the “stent opacity”single volume technology was used to display 5 types of stent which were released in 7 cases of pure intracranial artery stenting and 12 cases of stent-assisted aneurysm embolization.Then we applied “vessel translucent”and “vessel opacity”single volume technology to display corresponding vessel segments.Finally,by coalescing the single volume imaging of stent and vessel,the “vessel opacity + stent opacity”dual volume image and “vessel translucent+ stent opacity”dual volume image were performed.We compared the effects of two kinds of dual volume imaging and assessed the imaging characteristics and influencing factors of each method.Results (1)On the “stent opacity”single volume display mode,in 7 cases of pure intracranial artery stenting,the display effect of two Pipeline stents and three Apollo stents belongs to level 1,the display effect of two Enterprise stents belongs to level 2;In 12 cases of stent-assisted aneurysm embolization,in the stent segments which weren’t influenced by artifacts,the display effect of two LEVIS stents belongs to level 1,the display effects of 5 Enterprise stents and 2 Solitaire AB stents belongs to level 2;While in the stent segments which were influenced by the artifact of spring coil and bone,the display effect significantly reduced, three pieces of Enterprise stents were even unable to identify.(2)On the “vessel opacity”single volume display mode,1 9 cases of vessel segment at the stent completed opacity display.The surface structure of vessel was very clear,but the structure under the surface was completely being covered.On the “vessel translucent”single volume display mode,the surface structure of 19 cases of vessel segment at the stent displayed clear at the tangential position.The vessel

  6. Bypass surgery versus stenting for the treatment of multivessel disease in patients with unstable angina compared with stable angina

    NARCIS (Netherlands)

    P.J. de Feyter (Pim); P. van den Heuvel; F. Unger (Felix); R. Beyar; W.K. Lindeboom (Wietze); V. de Valk (Vincent); S. Milo; R. Simon (Rudiger); G.F.O. Tyers (Frank); D. Regensburger; P.A. Crean (Peter); I.M. Penn (Ian); E. McGovern; C. van Cauwelaert; P.W.J.C. Serruys (Patrick)

    2002-01-01

    textabstractBACKGROUND: Earlier reports have shown that the outcome of balloon angioplasty or bypass surgery in unstable angina is less favorable than in stable angina. Recent improvements in percutaneous treatment (stent implantation) and bypass surgery (arterial grafts) warrant reevaluation of the

  7. Perturbation-induced secondary flow structures due to fractured stents in arterial curvatures

    Science.gov (United States)

    Bulusu, Kartik V.; Popma, Christopher; Penna, Leanne; Plesniak, Michael W.

    2012-11-01

    An in vitro experimental investigation of secondary flow structures was performed downstream of a model stent that embodied a ``Type-IV'' stent fracture, i.e. complete transverse fracture of elements and element displacement (of 3 diameters). One part of the fractured stent was located in the curved region of a test section comprised of a 180-degree bent tube, and the velocity field measured with PIV. Secondary flow morphologies downstream of the stent were identified with a continuous wavelet transform (CWT) algorithm (PIVlet 1.2) using a 2D Ricker wavelet. A comparison of wavelet transformed vorticity fields of fractured and unfractured model stents is presented under physiological inflow conditions. During systolic deceleration, a breakdown in symmetry of vortical structures occurred with the unfractured stent, but not with the fractured model stent. Potential mechanisms to explain the differences in secondary flow morphologies include redirection of vorticity from the meridional plane of the bend to the normal plane and diffusion of vorticity. Supported by the National Science Foundation, Grant No. CBET-0828903 and GW Center for Biomimetics and Bioinspired Engineering (COBRE).

  8. Multiple coronary thrombosis and stent implantation to the subtotally occluded right renal artery in a patient with essential thrombocytosis: a case report with review.

    Science.gov (United States)

    Ozben, Beste; Ekmekci, Ahmet; Bugra, Zehra; Umman, Sabahattin; Meric, Mehmet

    2006-08-01

    Essential thrombocytosis is a myeloproliferative disorder of unknown etiology manifested clinically by the overproduction of platelets in the absence of a definable cause. Platelet dysfunction in essential thrombocytosis results in both hemorrhage and thrombosis. It is one of the rare causes of ischemic cardiovascular events. Fewer than 20 cases of essential thrombocytosis with involvement of coronary arteries leading to acute coronary syndromes or myocardial infarction have been reported. We report a case of multiple coronary thrombosis involving the left anterior descending artery and circumflex artery and stent implantation to the subtotally stenotic right renal artery in a women with unstable angina pectoris, essential thrombocytosis and previous history of renal artery trombosis.

  9. Open triple-branched stent graft applied to patient of acute type a aortic dissection with Aberrant Right Subclavian Artery

    OpenAIRE

    Guo, Changfa; Zhu, Kai; Xu, Demin; Wang, Chunsheng

    2013-01-01

    A 57-year-old Chinese male patient presented with Standford type A aortic dissection with an aberrant right subclavian artery (ARSA). At operation, the ascending aorta was replaced by a mono–branch vascular prosthesis with the branch bypassing to the ARSA; the triple-branched stent graft was inserted into the true lumen of the arch and proximal descending aorta (covering the origin of the ARSA) with each sidearm graft being positioned into the aortic branches; and then its proximal end was su...

  10. Six-month clinical outcomes of Firebird 2TM sirolimus-eluting stent implantation in real-world patients with coronary artery diseases

    Institute of Scientific and Technical Information of China (English)

    GE Jun-bo; ZHANG Feng; QIAN Ju-ying; GE Lei; LIU Xue-bo; ZHOU Jun

    2011-01-01

    Background The Firebird 2TM sirolimus-eluting stent (Firebird 2 stent) is a second-generation sirolimus-eluting stent which has a cobalt-chromium alloy stent platform, a brand new bracket structure, and two layers of styrene-butylenes-styrene polymer coatings with better biocompatibility. The Firebird 2TM cObalt-Chromium alloy sirolimus-elUting Stent registry (FOCUS registry) aimed to evaluate the safety and efficacy of the Firebird 2 stent in patients with coronary artery disease in daily practice.Methods The FOCUS registry is a prospective, non-randomized, international multi-center, single-arm clinical registry.Between March 2009 and February 2010, 5084 patients receiving at least 1 Firebird 2 stent during daily clinical practice at 83 medical centers were enrolled.Results Of the 5084 patients enrolled in the registry, 5077 and 5058 were respectively available for 30 days and 6 months follow-up. The 30-day rate of major adverse cardiac events (MACE) was 1.20%, including 13 cardiac deaths, 46 non-fatal myocardial infarction (MI), and 6 target vessel revascularization (TVR). At 6 months follow-up, the rate of MACE was 1.80%. There were 32 cardiac deaths, 48 non-fatal MI, and 15 TVR. According to the Academic Research Consortium definition, definite/probable stent thrombosis (ST) occurred in 0.43% (22/5058) of patients, including 8 cases of acute ST, 11 subacute ST, and 3 late ST.Conclusion The Firebird 2 stent showed the promising efficacy and safety at 30 days and 6 months in a real-world population of patients with coronary artery diseases.

  11. Multi-link Vision and MiniVision stent registry in Asian patients with coronary artery disease: a prospective, multi-center study

    Institute of Scientific and Technical Information of China (English)

    XU Ya-wei; HOU Yu-qing; Ashok Jain; Parvez Grant; Gudapati Ramesh; Basavappa Ramesh; Chumpol Piamsomboon; Srun Kuanprasert; Hyeon-Cheol Gwon; Yoon Haeng Cho; Haizal Haroon Kamar; WEI Yi-dong; HUANG Cong-xin; TANG Kai; CHEN Yan-qing; LI Wei-ming; YU Xue-jing; QIN Yong-wen; QI Guo-xian; QU Peng

    2007-01-01

    Background Recent studies have showed that the fine mesh stents are associated with a significant reduction in both clinical and angiographic re-stenosis of the coronary arteries. To maintain a very satisfactory radio-opacity using the stents, Guidant of the USA has designed a new type of bare metal stents (BMS)-Multi-link (ML) Vision / ML MiniVision stents. The clinical outcomes of Asian patients with coronary artery disease (CAD) after implanting the Multi-link Vision or MiniVision stent were investigated in this study.Methods An observational, prospective, multi-center, non-randomized post marketing registry was conducted to demonstrate the efficacy of the BMS- ML Vision / ML MiniVision stents. The primary end point of the registry was clinical target lesion revascularization (TLR) at a 6-month follow-up. The major secondary end points included the rate of major adverse cardiac events (MACE) and serious adverse events (SAE) in hospital and at 6 months; and the rate of clinical TLR as a function of the type of angina. A total of 429 Asian people with 449 lesions from 14 centers were selected for this study. The average reference diameter of the lesions was (3.0±0.5) mm, and the mean length was (15.7±5.0) mm.Results The successful rate of the procedure was 99.3%. Twenty-five percent of the lesions were treated by direct stenting without pre-dilation. Eighty-six percent of the lesions were implanted with ML Vision stent. After the 6-month follow-up, the rate of clinical TLR was 1.4%. The MACE, SAE and target vessel revascularization (TVR) were 6.8%, 3.5%and 1.4% respectively.Conclusion The current registry showed the excellent 6-month clinical outcomes of ML Vision/ML MiniVision stents in Asian patients with CAD.

  12. Comparison Between Balloon-Assisted and Stent-Assisted Technique for Treatment of Unruptured Internal Carotid Artery Aneurysms

    Science.gov (United States)

    Park, Keun Young; Kim, Dong Joon

    2016-01-01

    Purpose To compare clinical and angiographic outcomes between balloon-assisted (BAC) and stent-assisted coiling for internal carotid artery unruptured aneurysms (ICA-UA). Materials and Methods A total of 227 ICA-UA in 190 patients were treated with BAC (120 patients, 141 ICA-UA) or SAC (70 patients, 86 ICA-UA. We compared characteristics of patients and ICA-UA, and clinical and angiographic outcomes between groups. Results Aneurysm size and neck diameter were greater for SAC than in BAC, but aneurysm volume and coil packing density were not different between groups. Immediate angiographic occlusion grade was better for BAC than for SAC. Periprocedural thromboembolic events were more frequent during SAC (11.6%) than BAC (2.4%) per aneurysm, but hemorrhagic events were the opposite (2.4% for BAC and none for SAC per aneurysm) (p resulting in a modified Rankin scale score of 4. Thus, overall treatment-related morbi-mortality rates were 1.7% in BAC and 2.9% in SAC. At imaging follow-up (BAC, 135 aneurysms [95.7%] for 28.3 months; SAC, 81 aneurysms [94.1%] for 23.9 months), BAC and SAC showed stable or improved occlusion in 94.1% and 95.0%, minor recurrence in 4.4% and 2.5%, and major recurrence in 1.5% and 2.5%, respectively. Conclusion Both BAC and SAC were safe and effective techniques for ICA-UA. There were no differences in morbi-mortality and recurrence rates between groups. PMID:27621946

  13. Successful Endovascular Repair of an Iatrogenic Perforation of the Superficial Femoral Artery Using Self-Expanding Nitinol Supera Stents in a Patient with Acute Thromboembolic Limb Ischemia

    Directory of Open Access Journals (Sweden)

    Tom Eisele

    2016-01-01

    Full Text Available The treatment of acute thromboembolic limb ischemia includes well-established surgical thrombectomy procedures and, in recent times, also percutaneous rotational thrombectomy using Straub Rotarex® system. This modality not only enables efficient treatment of such thrombotic occlusion but also in rare cases may imply the risk of perforation of the occluded artery. Herein, we report the case of a perforation of the superficial femoral artery (SFA in an elderly female patient with thromboembolic limb ischemia. The perforation was successfully treated by implantation of self-expanding nitinol Supera stents and without the need for implantation of a stent graft.

  14. Long-term benefits and risks of drug-eluting compared to bare-metal stents in patients with versus without chronic kidney disease

    DEFF Research Database (Denmark)

    Wanitschek, Maria; Pfisterer, Matthias; Hvelplund, Anders;

    2013-01-01

    AIMS: Chronic kidney disease (CKD) is associated with worse outcomes in patients with coronary artery disease (CAD). How CKD influences the benefit-risk balance of drug-eluting stents (DES) versus bare-metal stents (BMS) is less known. METHODS AND RESULTS: In the multicentre BASKET-PROVE trial, 2...

  15. Comparison of short- and mid-term outcomes between CYPHER and TAXUS stents in patients with complex lesions of the coronary arteries

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background Drug-eluting stent (DES) could obviously reduce in-stent restenosis, which has been proved by international multi-center clinical trials. However, the types of the lesions for stenting were highly selected in these trials. Up to now, there has been no large scale study on the effect of DES in treating complex lesions in real world. Although REALITY trial was just reported during American College of Cardiology Congress 2005, the entry criteria for lesions were limited to one or two de novo lesions. This study was conducted to compare the short- and mid-term clinical outcomes between sirolimus-eluting stent (CYPHER stent) and paclitaxel-eluting stent (TAXUS stent) in patients with complex lesion. Methods This is a retrospective study. From April 2002 to June 2004, a total of 1061 patients were treated with DES in Fu Wai Hospital, of which, 611 patients (642 lesions with 698 CYPHER stents) were in CYPHER group,and 450 patients (534 lesions with 600 TAXUS stents) were in TAXUS group. There was no significant difference in clinical data and lesion types between CYPHER group and TAXUS group. Results Success rates of stent implantation were 99.2% and 98.8% in CYPHER and TAXUS stent groups respectively. The major adverse cardiac events (MACE) during in-hospital and 6-8-month follow-up were 0.7% and 2.3% in CYPHER stent group versus 1.3% and 3.2% in TAXUS stent group. There was no significant difference in MACE rate between these two groups. Restenosis rate was a little higher in TAXUS stent group than that in CYPHER stent group (14.0% vs 7.3%), but there was no significant difference. The incidence of acute occlusion of side branch after implanting DES in main vessel was 6.9% in CYPHER group and 11.9% in TAXUS group(P<0.05).Conclusions CYPHER and TAXUS DES were safe and effective in patients with complex lesion. Clinical outcomes of CYPHER stent were better than TAXUS stent in bifurcation lesions. There was an increasing tendency in restenosis rate and late

  16. A new stent with streamlined cross-section can suppress monocyte cell adhesion in the flow disturbance zones of the endovascular stent.

    Science.gov (United States)

    Chen, Zengsheng; Zhan, Fan; Ding, Jun; Zhang, Xiwen; Deng, Xiaoyan

    2016-01-01

    We proposed a new stent with streamlined cross-sectional wires, which is different from the clinical coronary stents with square or round cross-sections. We believe the new stent might have better hemodynamic performance than the clinical metal stents. To test the hypothesis, we designed an experimental study to compare the performance of the new stent with the clinical stents in terms of monocyte (U-937 cells) adhesion. The results showed that when compared with the clinical stents, the adhesion of U-937 cells were much less in the new stent. The results also showed that, when Reynolds number increased from 180 (the rest condition for the coronary arteries) to 360 (the strenuous exercise condition for the coronary arteries), the flow disturbance zones in the clinical stents became larger, while they became smaller with the new stent. The present experimental study therefore suggests that the optimization of the cross-sectional shape of stent wires ought to be taken into consideration in the design of endovascular stents.

  17. Secondary flow structures in the presence of Type-IV stent fractures through a bent tube model for curved arteries: Effect of circulation thresholding

    Science.gov (United States)

    Hussain, Shadman; Bulusu, Kartik V.; Plesniak, Michael W.

    2013-11-01

    A common treatment for atherosclerosis is the opening of narrowed arteries resulting from obstructive lesions by angioplasty and stent implantation to restore unrestricted blood flow. ``Type-IV'' stent fractures involve complete transverse, linear fracture of stent struts, along with displacement of the stent fragments. Experimental data pertaining to secondary flows in the presence of stents that underwent ``Type-IV'' fractures in a bent artery model under physiological inflow conditions were obtained through a two-component, two-dimensional (2C-2D) PIV technique. Concomitant stent-induced flow perturbations result in secondary flow structures with complex, multi-scale morphologies and varying size-strength characteristics. Ultimately, these flow structures may have a role to play in restenosis and progression of atherosclerotic plaque. Vortex circulation thresholds were established with the goal of resolving and tracking iso-circulation secondary flow vortical structures and their morphological changes. This allowed for a parametric evaluation and quantitative representation of secondary flow structures undergoing deformation and spatial reorganization. Supported by NSF Grant No. CBET- 0828903 and GW Center for Biomimetics and Bioinspired Engineering.

  18. Transcatheter stenting of the right ventricular outflow tract augments pulmonary arterial growth in symptomatic infants with right ventricular outflow tract obstruction and hypercyanotic spells.

    Science.gov (United States)

    McGovern, Eimear; Morgan, Conall T; Oslizlok, Paul; Kenny, Damien; Walsh, Kevin P; McMahon, Colin J

    2016-10-01

    We retrospectively reviewed all the children with right ventricular outflow tract obstruction, hypoplastic pulmonary annulus, and pulmonary arteries who underwent stenting of the right ventricular outflow tract for hypercyanotic spells at our institution between January, 2008 and December, 2013; nine patients who underwent cardiac catheterisation at a median age of 39 days (range 12-60 days) and weight of 3.6 kg (range 2.6-4.3 kg) were identified. The median number of stents placed was one stent (range 1-4). The median oxygen saturation increased from 60% to 96%. The median right pulmonary artery size increased from 3.3 to 5.5 mm (-2.68 to -0.92 Z-score), and the median left pulmonary artery size increased from 3.4 to 5.5 mm (-1.93 to 0 Z-scores). Among all, one patient developed transient pulmonary haemorrhage, and one patient had pericardial tamponade requiring drainage. Complete repair of tetralogy of Fallot +/- atrioventricular septal defect or double-outlet right ventricle was achieved in all nine patients. Transcatheter stent alleviation of the right ventricular outflow tract obstruction resolves hypercyanotic spells and allows reasonable growth of the pulmonary arteries to facilitate successful surgical repair. This represents a viable alternative to placement of a systemic-to-pulmonary artery shunt, particularly in small neonates.

  19. Drug-eluting stents:is it the beginning of the end for coronary artery bypass surgery?

    Institute of Scientific and Technical Information of China (English)

    Shahzad G Raja

    2004-01-01

    @@ Myocardial revascularization therapy of coronary artery disease is one of the most important medical advances of the past 50 years.1 Coronary revascularization by either bypass surgery or coronary angioplasty relieves angina and may improve the prognosis in patients with coronary artery disease.2,3 Randomized comparisons reveal no difference in survival free from myocardial infarction (MI) between surgery and balloon angioplasty.4,5 Stenting significantly improved the long-term outcome, while surgery is still associated with fewer reinterventions during follow-up.6-10 However, subsequent improvements in both percutaneous and surgical techniques may now limit the validity of any conclusions that have been drawn from the earlier studies. In fact, the lines of demarcation for patients suited for bypass or angioplasty are becoming blurry with each passing day.

  20. Drug-eluting stents vs. coronary artery bypass-grafting in coronary heart disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2008-12-01

    Full Text Available Background: Coronary artery bypass graft (CABG and percutaneous revascularisations with implantation of drug-eluting stents (DES are important treatment methods in coronary heart disease (CHD. Research questions: The evaluation addresses questions on medical efficacy, health economic parameters as well as ethic, social and legal implications in the use of DES vs. CABG in CHD patients. Methods: A systematic literature search was conducted in December 2006 in the most important electronic databases beginning from 2004. Register data and controlled clinical studies were included in the evaluation. Additionally, a health economic modelling was conducted. Results: Medical evaluation: The literature search yielded 2,312 hits. 14 publications about six controlled clinical studies and five publications about two registers were included into the evaluation. Register data showed low mortality (0.2% to 0.7% and low rates of myocardial infarction (0.5% to 1.4% during hospital stay. In patients with stenosis of the left anterior descending coronary artery one study showed in several analyses a significantly higher rate of reinterventions and a significantly higher rate of repeated angina pectoris for DES up to two years after the implantation (16.8% vs. 3.6% and 35% vs. 8%. In patients with left main coronary artery stenosis two studies revealed a significantly higher survival without myocardial infarction and stroke for DES up to one year (96% vs. 79% and 95% vs. 91% and two studies a significantly higher rate of revascularisations up to two years (20% vs. 4% and 25% vs. 5% after the primary intervention. In patients with multivessel disease, one study found a significantly higher mortality and myocardial infarction rate for CABG at one year (2.7% vs. 1.0% and 4.2% vs. 1.3%. The rate of revascularisations was significantly higher in two studies up to two years after DES implantation (8.5% vs. 4.2% and 14.2% vs. 5.3%. The rate at repeated angina pectoris was

  1. Local sustained delivery of acetylsalicylic acid via hybrid stent with biodegradable nanofibers reduces adhesion of blood cells and promotes reendothelialization of the denuded artery

    Directory of Open Access Journals (Sweden)

    Lee CH

    2014-01-01

    Full Text Available Cheng-Hung Lee,1,2 Yu-Huang Lin,3 Shang-Hung Chang,1 Chun-Der Tai,3 Shih-Jung Liu,2 Yen Chu,4 Chao-Jan Wang,5 Ming-Yi Hsu,5 Hung Chang,6 Gwo-Jyh Chang,7 Kuo-Chun Hung,1 Ming-Jer Hsieh,1 Fen-Chiung Lin,1 I-Chang Hsieh,1 Ming-Shien Wen,1 Yenlin Huang81Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Linkou, 2Department of Mechanical Engineering, 3Graduate Institute of Medical Mechatronics, Chang Gung University, 4Laboratory of Cardiovascular Physiology, Division of Thoracic and Cardiovascular Surgery, 5Department of Medical Imaging and Intervention, 6Hematology-Oncology Division, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, 7Graduate Institute of Clinical Medicinal Sciences, Chang Gung University College of Medicine, Linkou, 8Department of Anatomical Pathology, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, TaiwanAbstract: Incomplete endothelialization, blood cell adhesion to vascular stents, and inflammation of arteries can result in acute stent thromboses. The systemic administration of acetylsalicylic acid decreases endothelial dysfunction, potentially reducing thrombus, enhancing vasodilatation, and inhibiting the progression of atherosclerosis; but, this is weakened by upper gastrointestinal bleeding. This study proposes a hybrid stent with biodegradable nanofibers, for the local, sustained delivery of acetylsalicylic acid to injured artery walls. Biodegradable nanofibers are prepared by first dissolving poly(D,L-lactide-co-glycolide and acetylsalicylic acid in 1,1,1,3,3,3-hexafluoro-2-propanol. The solution is then electrospun into nanofibrous tubes, which are then mounted onto commercially available bare-metal stents. In vitro release rates of pharmaceuticals from nanofibers are characterized using an elution method, and a high-performance liquid chromatography assay. The experimental results suggest that biodegradable nanofibers

  2. Retreatment and outcomes of recurrent intracranial vertebral artery dissecting aneurysms after stent assisted coiling: a single center experience.

    Directory of Open Access Journals (Sweden)

    Ying Song

    Full Text Available The retreatment of recurrent intracranial vertebral artery dissecting aneurysms (VADAs after stent assisted coiling (SAC has not yet been studied. The purpose of this study was to evaluate the strategies and outcomes for retreatment of recurrent VADAs after SAC.Between September 2009 and November 2013, six consecutive patients presenting with recurrent intracranial VADAs after SAC were enrolled in this study. They were all male with age ranging from 29 to 54 years (mean age, 46.2 years. The procedures of treatments and angiographic and clinical follow-up were reviewed retrospectively. Retreatment modalities were selected individually according to the characteristics of recurrence. The outcomes of retreatment were evaluated by angiographic and clinical follow-up.Six patients with recurrent intracranial VADAs after SAC were retreated, with second SAC in three patients, coil embolization, double overlapping stents placement and endovascular occlusion with aneurysm trapping in one patient, respectively. Immediate angiographic outcomes of retreatment were: complete occlusion in three patients, nearly complete occlusion in two patients, and contrast medium retention in dissecting aneurysm in one patient. All cases were technically successful. No complications related to endovascular procedures occurred. Angiographic follow-up was available in all five patients treated with second SAC or double overlapping stents, which was complete occlusion in four patients, obliteration of parent artery in one patient, showing no recurrence at 4-11 months (mean: 8.6 months. Clinical follow-up was performed in all six patients at 11-51 months after initial endovascular treatment and at 9-43 months after retreatment. The mRS of last clinical follow-up was excellent in five patients and mild disability in only one patient.Endovascular retreatment is feasible and effective for recurrent intracranial VADAs after SAC. Individualized strategies of retreatment should be

  3. Application of a mechanobiological simulation technique to stents used clinically.

    Science.gov (United States)

    Boyle, Colin J; Lennon, Alex B; Prendergast, Patrick J

    2013-03-15

    Many cardiovascular diseases are characterised by the restriction of blood flow through arteries. Stents can be expanded within arteries to remove such restrictions; however, tissue in-growth into the stent can lead to restenosis. In order to predict the long-term efficacy of stenting, a mechanobiological model of the arterial tissue reaction to stress is required. In this study, a computational model of arterial tissue response to stenting is applied to three clinically relevant stent designs. We ask the question whether such a mechanobiological model can differentiate between stents used clinically, and we compare these predictions to a purely mechanical analysis. In doing so, we are testing the hypothesis that a mechanobiological model of arterial tissue response to injury could predict the long-term outcomes of stent design. Finite element analysis of the expansion of three different stent types was performed in an idealised, 3D artery. Injury was calculated in the arterial tissue using a remaining-life damage mechanics approach. The inflammatory response to this initial injury was modelled using equations governing variables which represented tissue-degrading species and growth factors. Three levels of inflammation response were modelled to account for inter-patient variability. A lattice-based model of smooth muscle cell behaviour was implemented, treating cells as discrete agents governed by local rules. The simulations predicted differences between stent designs similar to those found in vivo. It showed that the volume of neointima produced could be quantified, providing a quantitative comparison of stents. In contrast, the differences between stents based on stress alone were highly dependent on the choice of comparison criteria. These results show that the choice of stress criteria for stent comparisons is critical. This study shows that mechanobiological modelling may provide a valuable tool in stent design, allowing predictions of their long

  4. Successful endovascular treatment of a growing megadolichoectasic vertebrobasilar artery aneurysm by flow diversion using the "diverter-in-stent" technique.

    Science.gov (United States)

    Cohen, José E; Gomori, John M; Moscovici, Samuel; Itshayek, Eyal

    2012-01-01

    Giant dolichoectatic and fusiform aneurysms of the vertebrobasilar artery are among the most difficult and dangerous aneurysms to treat. Conservative management may be reasonable in asymptomatic elderly patients. Nevertheless, due to the frequent presence of mass effect on the brainstem and the risks of thromboembolic events and rupture, these aneurysms often demand treatment rather than observation. With the advancement of endovascular techniques some of these lesions have become treatable without the high morbidity and mortality rates associated with open surgical treatment. When dealing with giant, progressively enlarging symptomatic aneurysms, more limited therapeutic alternatives are available. The authors present a case of a growing megadolichoectatic vertebrobasilar artery aneurysm causing major disability due to increasing mass effect in a 51-year-old man. The aneurysm was treated with flow diversion by placing multiple telescoped stents and diverters ("diverter-in-stent" technique), achieving thrombosis of the aneurysm and reduction of the mass effect on the brainstem, with neurological improvement. The successful clinical and angiographic results observed in our case of giant dolichoectasic vertebrobasilar aneurysm contribute to the literature on giant aneurysms treated by means of flow diversion.

  5. Successful treatment of cardiogenic shock by stenting of the left main coronary artery in acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Knežević Božidarka

    2008-01-01

    Full Text Available Introduction. Patients with non-ST elevation acute coronary syndromes (NSTE-ACS are sometimes severely hemodynamicly compromised. Urgent coronary angiography should be performed in these patients in percutaneous coronary intervention (PCI centers according to the ESC NSTE-ACS guidelines to determine suitabilty for percutaneous or surgical revascularization. Case report. We reported a 62-year-old male with chest pain admitted to the Coronary Care Unit. ST segment depression of 2 mm in leads I, L and V4-6 was revealed at electrocardiogram. After following 6 hours the patient had chest pain and signs of cardiogenic shock despite of the therapy. Chest x-ray showed pulmonary edema. Echocardiographic examination showed dyskinetic medium and apical segments of septum. The patient underwent coronary angiography immediately which revealed 75% stenosis of the left main coronary artery with thrombus. The use of a GPIIb/III inhibitor-tirofiban and stent implantation resulted in TIMI III flow. After that the patient had no chest pain and acute heart failure subsided in the following days Echocardiography done at the fourth day from PCI showed only hypokinesis medium and apical segment of septum. The patient was discharged at day 11 from admission in a stable condition. Conclusion. Stenting of left main coronary artery stenosis in patients with cardiogenic shock and non- ST segment elevation acute coronary syndromes may be a life saving procedure.

  6. A randomized, open-label clinical trial using optical coherence tomography to compare two sirolimus-eluting stents, one with a biodegradable polymer and the other with a permanent polymer.

    Science.gov (United States)

    Tian, Feng; Chen, Yundai; Liu, Changfu; Jin, Qinhua; Chen, Lian; Sun, Zhijun; Liu, Hongbin; Guo, Jun; Gai, Luyue

    2013-04-01

    Intimal hyperplasia appears to differ after implanting a drug-eluting stent (DES) with a biodegradable or a permanent polymer. The aim of the present study was to compare biodegradable with permanent polymer DES, since the available data are limited. One hundred patients with de novo coronary artery stenosis were included in this study. The patients were classified into 2 groups: DES with a biodegradable polymer (n=50) and DES with a permanent polymer (n=50). Optical coherence tomography (OCT) examination was performed before and after stent implantation. A follow‑up OCT, performed 1 year after stent implantation, compared the morphologies of intimal hyperplasia in the 2 groups. The frequencies of uncovered stent struts (2.27 vs. 1.87%, P=0.145) and stent strut malapposition (1.9 vs. 2.02%, P=0.655) upon the first-year follow-up were not significantly different. Average neointimal thickness was lower in the biodegradable compared with the permanent polymer group (106.12±80.65 vs. 181.20±146.96 µm, Pbiodegradable compared with the permanent polymer group (62.1 vs. 35.9%, Pbiodegradable compared with the permanent polymer group (57.7±24.6 vs. 67.6±22.4 µm, Pbiodegradable polymer DES resulted in significantly lower intimal hyperplasia and had well-proportioned intimal coverage compared with permanent polymer DES.

  7. Secreted Matrix Metalloproteinase-9 of Proliferating Smooth Muscle Cells as a Trigger for Drug Release from Stent Surface Polymers in Coronary Arteries.

    Science.gov (United States)

    Gliesche, Daniel G; Hussner, Janine; Witzigmann, Dominik; Porta, Fabiola; Glatter, Timo; Schmidt, Alexander; Huwyler, Jörg; Meyer Zu Schwabedissen, Henriette E

    2016-07-01

    Cardiovascular diseases are the leading causes of death in industrialized countries. Atherosclerotic coronary arteries are commonly treated with percutaneous transluminal coronary intervention followed by stent deployment. This treatment has significantly improved the clinical outcome. However, triggered vascular smooth muscle cell (SMC) proliferation leads to in-stent restenosis in bare metal stents. In addition, stent thrombosis is a severe side effect of drug eluting stents due to inhibition of endothelialization. The aim of this study was to develop and test a stent surface polymer, where cytotoxic drugs are covalently conjugated to the surface and released by proteases selectively secreted by proliferating smooth muscle cells. Resting and proliferating human coronary artery smooth muscle cells (HCASMC) and endothelial cells (HCAEC) were screened to identify an enzyme exclusively released by proliferating HCASMC. Expression analyses and enzyme activity assays verified selective and exclusive activity of the matrix metalloproteinase-9 (MMP-9) in proliferating HCASMC. The principle of drug release exclusively triggered by proliferating HCASMC was tested using the biodegradable stent surface polymer poly-l-lactic acid (PLLA) and the MMP-9 cleavable peptide linkers named SRL and AVR. The specific peptide cleavage by MMP-9 was verified by attachment of the model compound fluorescein. Fluorescein release was observed in the presence of MMP-9 secreting HCASMC but not of proliferating HCAEC. Our findings suggest that cytotoxic drug conjugated polymers can be designed to selectively release the attached compound triggered by MMP-9 secreting smooth muscle cells. This novel concept may be beneficial for stent endothelialization thereby reducing the risk of restenosis and thrombosis.

  8. Recent developments in drug-eluting coronary stents.

    Science.gov (United States)

    Yildiz, Mustafa; Yildiz, Banu Sahin; Gursoy, Mustafa Ozan; Akin, Ibrahim

    2014-01-01

    The interventional treatment of coronary artery disease was introduced in 1970`s by Andreas Grüntzig. The initial treatment strategy with plain old balloon angioplasty (POBA) was associated with high restenosis rates. The introduction of coronary stents, especially drug-eluting stents (DES) in 2002 has improved the results by lowering the rate of in-stent restenosis from 20-40% in the era of bare-metal stent (BMS) to 6-8%. However, in 2006 with the observation of late stent thrombosis the reputations of DES have decreased. However, improvements in stent design especially antiproliferative agents, polymeric agents as well as stent platforms improved newer generation DES. In controlled trials as well as registries the use of second-generation DES as compared to bare-metal stents (BMS) was associated with better clinical and angiographic results. A further development of these stents with use of biodegradable polymers, polymer-free stents, and biodegradable stents on the basis of poly L-lactide (PLLA) or magnesium resulted in third-generation DES and has been evaluated in preclinical and first clinical trials. However, to date, there is a lack of data comparing these third-generation DES with first- and second-generatrion DES in a large scale.

  9. Temporary arterial stenting in a full-house spaghetti wrist injury in a remote rural setting: benefit for hand perfusion or risk of increased morbidity?

    OpenAIRE

    Bauer, Stefan; Savundra, James

    2013-01-01

    We report a case of temporary arterial plastic tube stenting of the ulnar and radial artery in a complete spaghetti wrist injury in a remote rural setting. Exploration in a specialist centre 18 h postinjury revealed that the tubes were clotted off with adjacent thrombi but hand perfusion was maintained. Intimal damage required vein grafting of both arteries 24 h postinjury. Hand perfusion was not compromised at follow-up. This case highlights that arterial hand perfusion can be maintained wit...

  10. Limited Role for Biliary Stent as Surrogate Fiducial Marker in Pancreatic Cancer: Stent and Intratumoral Fiducials Compared

    Energy Technology Data Exchange (ETDEWEB)

    Horst, Astrid van der, E-mail: a.vanderhorst@amc.uva.nl [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Lens, Eelco; Wognum, Silvia; Jong, Rianne de [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Hooft, Jeanin E. van [Department of Gastroenterology and Hepatology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Tienhoven, Geertjan van; Bel, Arjan [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands)

    2014-07-01

    Purpose: Because of low soft-tissue contrast of cone beam computed tomography (CBCT), fiducial markers are often used for radiation therapy patient setup verification. For pancreatic cancer patients, biliary stents have been suggested as surrogate fiducials. Using intratumoral fiducials as standard for tumor position, this study aims to quantify the suitability of biliary stents for measuring interfractional and respiratory-induced position variations of pancreatic tumors. Methods and Materials: Eleven pancreatic cancer patients with intratumoral fiducials and a biliary stent were included in this study. Daily CBCT scans (243 in total) were registered with a reference CT scan, based on bony anatomy, on fiducial markers, and on the biliary stent, respectively. We analyzed the differences in tumor position (ie, markers center-of-mass position) among these 3 registrations. In addition, we measured for 9 patients the magnitude of respiratory-induced motion (MM) of the markers and of the stent on 4-dimensional CT (4DCT) and determined the difference between these 2 magnitudes (ΔMM). Results: The stent indicated tumor position better than bony anatomy in 67% of fractions; the absolute difference between the markers and stent registration was >5 mm in 46% of fractions and >10 mm in 20% of fractions. Large PTV margins (superior-inferior direction, >19 mm) would be needed to account for this interfractional position variability. On 4DCT, we found in superior-inferior direction a mean ΔMM of 0.5 mm (range, –2.6 to 4.2 mm). Conclusions: For respiratory-induced motion, the mean ΔMM is small, but for individual patients the absolute difference can be >4 mm. For interfractional position variations, a stent is, on average, a better surrogate fiducial than bony anatomy, but large PTV margins would still be required. Therefore, intratumoral fiducials are recommended for online setup verification for all pancreatic patients scheduled for radiation therapy, including

  11. Current status of infrapopliteal artery stenting in patients with critical limb ischemia Estado atual do uso de stents na artéria infrapolítea em pacientes com isquemia crítica do membro

    Directory of Open Access Journals (Sweden)

    Marc Bosiers

    2008-09-01

    Full Text Available Due to the fear that early thrombosis and late luminal loss resulting from intimal hyperplasia might impede sustained patency of small-caliber arteries, such as those of the infrapopliteal bed, stent implantation in below-knee vessels remains controversial and is generally reserved for cases with a suboptimal outcome after percutaneous transluminal angioplasty (i.e. > 50% residual stenosis, flow-limiting dissection. Although evidence starts to build, favoring the use of stenting in the tibial area, results of well-conducted randomized controlled trials have to be awaited to change this strategy. Because of diameter similarities with coronary arteries, the first stents applied in the infrapopliteal vessels were all coronary devices. Once the feasibility of the stenting approach with these coronary products was shown, device manufacturers started to develop a dedicated infrapopliteal product range. To date, a broad spectrum of stent types has been used and investigated for the given indication. This article overviews the available literature and results of different balloon-expandable (bare metal, passive coated, drug eluting, self-expanding and absorbable stent types available for below-the-knee application and gives recommendations for future device technology advancements.Devido ao receio de que a trombose precoce ou a estenose tardia por hiperplasia intimal possam impedir a manutenção da perviedade em vasos de pequeno calibre, o uso de stents pós-angioplastia no leito arterial infrapoplíteo permanece controverso e geralmente é reservado aos casos de resultado subótimo após angioplastia transluminal percutânea (isto é, estenose residual > 50% ou dissecção com limitação do fluxo. Apesar de evidências começarem a favorecer o uso de stents no segmento tibial, é necessário aguardar o resultado de ensaios controlados, randomizados e bem conduzidos para mudar esta estratégia. Sendo estes vasos infrapoplíteos de diâmetro similar

  12. Impact of the introduction of drug eluting stents on clinical outcomes in patients undergoing percutaneous and surgical coronary artery revascularisation procedures in Western Australia

    OpenAIRE

    Sanfilippo, Frank M; Rankin, Jamie M.; Hobbs, Michael ST; Nguyen, Michael; Knuiman, Matthew W; Berg, Patricia; Whitford, Eric G; Hendriks, Randall; Hockings, Bernard E; Muhlmann, Michael; Newman, Mark; Larbalestier, Robert; Gilfillan, Ian; Briffa, Thomas G

    2013-01-01

    Background Increasing rates of percutaneous coronary intervention (PCI) and decreasing rates of coronary artery bypass graft (CABG) surgery followed the introduction of drug eluting stents in Western Australia in 2002. We assessed the impact of these changes on one-year outcomes for the total population of patients undergoing coronary artery revascularisation procedures (CARP) in Western Australia between 2000-2004. Methods Clinical and linked administrative data (inpatient admissions and dea...

  13. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar;

    2014-01-01

    BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...

  14. [Comparative characteristics of the open and endovascular methods of treatment for carotid artery stenoses].

    Science.gov (United States)

    Krotovskiĭ, G S; Uchkin, I G; Shugushev, Z Kh; Zudin, A M; Kagdasarian, A G

    2010-01-01

    The article is dedicated to the problem concerning treatment for stenoses of the extracranial portions of carotid arteries. From March 2004 to November 2009 at the Department of Vascular Surgery No 2 of the N. A. Semashko Central Clinical Hospital No 2 we treated a total of 364 patients presenting with stenotic lesions of the extracranial portion of the carotid arteries. Of these, 176 patients underwent revascularization of the carotid basin: 120 patients endured open carotid endarterectomy (CEAE), 56 patients sustained carotid angioplasty and stenting (CAS), with a total of 128 CEAE and 67 CAS interventions performed. The following conclusion was made: with high skill of surgeons and broad experience in carrying out revascularization of the carotid basin, the CEAE and CAS procedures possess comparable efficacy and safety with CEAE possessing reliable advantage in terms of the parameters of the patient's quality of life.

  15. The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Chee, Hyun Keun; Park, Sang Woo; Yun, Ik Jin; Hwang, Jae Joon; Lee, Song Am; Kim, Jun Seok; Chang, Seong Hwan; Jung, Hong Geun [Konkuk University Hospital, Seoul (Korea, Republic of)

    2011-04-15

    We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at the 2-year follow-up did not have stent fracture. The primary patency was 94%, 61% and 44% at 1, 3 and 6 months, respectively, and the group with stent implantation up to P3 had a higher fracture rate than that of the group that underwent stenting up to P2 (p < 0.05). We suggest that stent placement up to the popliteal arterial P3 segment and over P2 in an Asian population can worsen the stent patency owing to stent fracture. It may be necessary to develop a stent design and structure for the Asian population that can resist the bending force in the knee joint

  16. Effectiveness of sirolimus-eluting stent implantation for the treatment of coronary artery disease in octogenarians.

    Science.gov (United States)

    Vijayakumar, Maniyal; Lemos, Pedro A; Hoye, Angela; Ong, Andrew T L; Aoki, Jiro; Granillo, Gaston Rodriguez; McFadden, Eugene P; Sianos, Georgios; Hofma, Sjoerd H; Smits, Pieter C; van der Giessen, Willem J; de Feyter, Pim; van Domburg, Ron T; Cummins, Paul A; Serruys, Patrick W

    2004-10-01

    Sirolimus-eluting stent (SES) implantation has been shown to reduce repeat revascularization in various randomized trials. The present study evaluated the outcomes after SES implantation in 46 octogenarian patients. SES implantation in octogenarians appears to be feasible and is associated with very small subsequent need for repeat target vessel revascularization at 1 year.

  17. Treatment of intracranial aneurysms. Reconstruction of the parent artery with flow-diverting (Silk) stent

    DEFF Research Database (Denmark)

    Wagner, Aase; Cortsen, Marie; Hauerberg, John;

    2011-01-01

    the periprocedural complications, immediate result, late complications, imaging follow-up at 6 and 12 months and clinical follow-up at 2-23 months. METHODS: Twenty-two patients with 26 wide-necked or blister-like aneurysms had 23 treatments with implantation of a Silk stent. Eleven patients had re...

  18. Safety and efficacy of the Perclose suture-mediated closure device following carotid artery stenting under clopidogrel platelet blockade

    Energy Technology Data Exchange (ETDEWEB)

    Zorger, Niels; Finkenzeller, Thomas; Lenhart, Markus; Hamer, Okka; Paetzel, Christian; Borisch, Inghita; Toepel, Ingolf; Feuerbach, Stefan; Link, Johann [University of Regensburg Klinikum, Franz-Josef-Strauss-Allee 11, 93042, Regensburg (Germany)

    2004-04-01

    The aim of this study was evaluation of a closure device (Perclose, Menlo Park, Calif.) for closure of the femoral artery access site in patients undergoing aggressive anticoagulation and platelet blockade after carotid stenting. Fifty-five patients who received clopidogrel in addition to aspirin and heparin as medication for carotid stenting were included for suture of the femoral access site after using 7- or 8-F guide catheters. The technical success, the time for suture, the clotting parameters, and complications were examined. Follow-up investigations, including ultrasound and clinical examinations, were performed. The groin was checked for possible hematoma, pseudoaneurysm, arteriovenous fistula, and local infection. Technical success was obtained in 51 of 54 patients (94%) after a mean procedure time of 6 min (range 5-10 min). The suture device was not used in one patient (2%) for anatomical reasons and failed to obtain hemostasis in 3 of 54 (6%) patients. In 4 of 54 patients (7%) bleeding was observed at the punctured site 4-6 h after intervention which was treated by a compression bandage. The mean dedicated activated clotting time was 137 s (range 29-287 s) before intervention and 349 s (150-958 s) just before deploying the Perclose device. During follow-up after 2 days (range 2-6 days) and 6 months no further complications of the puncture site were observed except for two large groin hematomas. No major complications occurred. Closure of the femoral access site after carotid stenting using a Perclose closure device is safe and effective even in patients receiving an aggressive anticoagulation and antiplatelet therapy. (orig.)

  19. Biodegradable polymer Biolimus-eluting stent (Nobori® for the treatment of coronary artery lesions: review of concept and clinical results

    Directory of Open Access Journals (Sweden)

    Schurtz G

    2014-02-01

    Full Text Available Guillaume Schurtz,1,2 Cédric Delhaye,1 Christopher Hurt,1,2 Henri Thieuleux,1,2 Gilles Lemesle1–3 1Centre Hémodynamique et Unité des Soins Intensifs de Cardiologie, Hôpital Cardiologique, Centre Hospitalier Régional et Universitaire de Lille, Lille, France; 2Faculté de Médecine de Lille, Lille, France; 3Unité INSERM UMR744, Institut Pasteur de Lille, Lille, France Abstract: First-generation drug-eluting stents have raised concerns regarding the risk of late and very late stent thrombosis compared with bare metal stents and require prolonged dual antiplatelet therapy. Despite extensive investigations, the physiopathology of these late events remains incompletely understood. Aside from patient- and lesion-related risk factors, stent polymer has been cited as one of the potential causes. In fact, the persistence of durable polymer after complete drug release has been shown to be responsible for local hypersensitivity and inflammatory reactions. Third-generation drug-eluting stents with more biocompatible or biodegradable polymers have subsequently been developed to address this problem. In this article, we evaluate and discuss the concept and clinical results (safety and efficacy of a third-generation drug-eluting stent with biodegradable polymer: the Nobori® stent. Keywords: percutaneous coronary intervention, stent thrombosis, antiplatelet therapy

  20. Drug-Eluting Nitinol Stent Treatment of the Superficial Femoral Artery and Above-the-Knee Popliteal Artery (The Zilver PTX Single-Arm Clinical Study): A Comparison Between Diabetic and Nondiabetic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological Sciences (Italy); Primo, Massimiliano Di [Hopital Europeen Georges Pompidou, University Paris Descartes (France); Boatta, Emanuele [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological Sciences (Italy); Johnston, Krystal, E-mail: kjohnston@medinst.com [MED Institute, Inc (United States); Sapoval, Marc, E-mail: marc.sapoval2@egp.aphp.fr [Hopital Europeen Georges Pompidou, University Paris Descartes (France)

    2013-10-15

    Purpose: To describe the 1-year results of drug-eluting nitinol stent placement in the femoropopliteal artery of diabetic and nondiabetic patients. Materials and Methods: All patients enrolled in this prospective, multicenter study underwent paclitaxel-eluting stent placement for de novo or restenotic lesions of the superficial femoral and/or popliteal artery. Baseline and follow-up walking impairment questionnaire (WIQ) scores, Rutherford classifications, and ankle-brachial index (ABI) measurements were obtained. Follow-up was completed at 1, 6, and 12 months. Results: There were 285 diabetic patients and 502 nondiabetic patients treated. There were no significant differences in mean lesion length or lesion calcification between patient groups. Procedural success in both treatment groups was >97 %. There were no significant differences between diabetic and nondiabetic groups in Kaplan-Meier estimates of patency, event-free survival (EFS), or freedom from target lesion revascularization (TLR) at 6 and 12 months. Both groups experienced a significant increase in ABI and WIQ values after treatment, and these improvements were sustained to 12-month follow-up; however, nondiabetic patients had significantly greater 6- and 12-month WIQ scores compared with diabetic patients. Based on covariate analysis, the only factors shown to be significant and to negatively influence patency were longer lesion length (p = 0.009), higher Rutherford classification (p = 0.02), and lack of hypertension (p = 0.02); diabetic status was not found to be a significant factor. Conclusion: Diabetic and nondiabetic patients had similar estimates of primary patency, EFS, and freedom from TLR; however, diabetic patients showed less improvement in WIQ scores compared with nondiabetic patients.

  1. 雷帕霉素与紫杉醇洗脱支架置入治疗冠状动脉病变的有效性%Efficacy of rapamycin and paclitaxel eluting stent implantation in treatment of coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    杨俊; 陈冬林; 陈银朝; 陈新敬

    2015-01-01

    背景:药物洗脱支架置入治疗冠状动脉病变具有良好的临床效果,但不同支架的治疗效果可能存在一定差异。目的:比较不同支架置入治疗冠状动脉病变的临床效果。方法:纳入278例冠状动脉病变患者,均接受冠状动脉支架置入治疗,其中91例置入雷帕霉素洗脱支架,92例置入紫杉醇洗脱支架,95例置入裸金属支架。支架置入后随访12个月,记录死亡和心肌梗死等不良心脏事件发生情况,以及冠状动脉再狭窄发生情况及材料宿主反应。结果与结论:雷帕霉素洗脱支架组与紫杉醇洗脱支架组冠状动脉再狭窄率、急性心肌梗死发生率、冠状动脉旁路移植或再次经皮冠状动脉介入治疗率均低于裸金属支架组(P0.05)。3组死亡率比较差异无显著性意义(P>0.05)。3组均未发生支架移位、脱落、断裂、置入位置不良及白细胞增多和血小板减少、溶血等情况。表明两种药物洗脱支架的治疗效果相当,均优于裸金属支架。%BACKGROUND: The clinical effect of drug-eluting stent implantation in treatment of coronary artery disease is good, but there may be some differences in the therapeutic effect between different stents. OBJECTIVE:To compare the clinical effect of different stent implantation in treatment of coronary artery disease. METHODS:A total of 278 patients with coronary artery disease were enroled and al underwent coronary artery stent implantation treatment, of which 91 patients underwent implanted rapamycin eluting stent, 92 patients underwent implanted paclitaxel eluting stent, and 95 patients underwent implanted bare metal stents. Al the patients were folowed up for 12 months after stents implantation. The occurrence of adverse cardiac events such as death, myocardial infarction, and the occurrence of coronary restenosis and host reaction were recorded. RESULTS AND CONCLUSION:The rates of coronary artery stenosis, acute

  2. High field MR imaging: magnetic field interactions of aneurysm clips, coronary artery stents and iliac artery stents with a 3.0 Tesla MR system; Hochfeld-Magnetresonanztomographie: Magnetische Anziehungs- und Rotationskraefte auf metallische Implantate bei 3,0 T

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T.; Schmiedel, A.; Hackenbroch, M.; Hofer, U.; Urbach, H.; Traeber, F.; Schild, H. [Radiologische Univ. Bonn (Germany); Maintz, D. [Radiologische Univ. Muenster (Germany); Pavlidis, C. [Klinik fuer Neurochirurgie, Univ. Bonn (Germany); Hoeher, M. [Medizinische Univ. II Ulm (Germany)

    2004-05-01

    Purpose: to evaluate magnetic field interactions of commonly used biomedical implants at 3.0 tesla. Materials and methods: fourteen aneurysm clips designed for permanent placement in intracranial aneurysms, 19 coronary artery stents and 20 iliac artery stents were evaluated in an actively shielded compact 3.0 T MR system (Intera, Philips Medical Systems, Best, the Netherlands, length of magnet 1.57 m). The magnetic deflection forces (translational movement) were evaluated as follows: the implants were suspended by a fine string and placed in the magnet bore at the location of the maximum magnetic field gradient. The translational forces F{sub z} were calculated from the measured angle of deflection from the vertical axis. The magnetic field-induced torque (rotational forces) was evaluated as follows: each implant was placed in the center of the magnetic bore parallel to the static magnetic field B0 (position 0 ). Any possible displacement of the implant was noted on a millimeter scale and any torque qualitatively evaluated using a 5 point grading scale (0: no torque; + 4: very strong torque). The implant was turned in steps of 45 , and the procedure was repeated to encompass a full 360 rotation. Results: in 52 of the 53 devices tested, the deflection force (deflection angle: range 0-21 , translational force: range 0-3.8 mN) was less than the gravitational force (i.e., the implant's weight). These devices (n = 52/53) did not show any alignment to or rotation in the magnetic field at any of the various 45 -increment positions corresponding to a qualitative torque evaluation of grade 0/4. One device (n = 1/53), an iliac artery stent made of stainless steel (Zenith, Cook, Moenchengladbach, BRD), was found to have deflection forces (deflection angle 88 translational force 299 mN) greatly exceeding the gravitational force as well as a pronounced torque (grade 4/4). (orig.) [German] Ziel: Die In-vitro-Evaluierung verschiedener biomedizinischer Implantate hinsichtlich

  3. Neointimal hyperplasia after sirolimus-eluting and paclitaxel-eluting stent implantation in diabetic patients: the Randomized Diabetes and Drug-Eluting Stent (DiabeDES) Intravascular Ultrasound Trial

    DEFF Research Database (Denmark)

    Jensen, L.O.; Maeng, M.; Thayssen, P.;

    2008-01-01

    AIMS: Patients with diabetes have increased risk of in-stent restenosis after coronary stent implantation owing to neointimal hyperplasia (NIH). The aim of the study was to evaluate the extent and distribution of NIH with intravascular ultrasound (IVUS) after coronary artery stenting with sirolimus......-eluting (Cypher) or paclitaxel-eluting (Taxus) stents in diabetic patients. METHODS AND RESULTS: One hundred and thirty diabetic patients were randomized to Cypher or Taxus stent implantation. IVUS was performed at 8 month follow-up. NIH volume was significantly reduced in the Cypher group when compared...... with the Taxus group: median (inter-quartile range) 0.0 (0.0-0.0) vs. 8.0 mm(3) (0.1-33.0), P stents compared with Taxus stents: median (inter-quartile range) 0.0 (0.0-0.0) vs. 7.5% (0.1-27.0), P stent...

  4. Angioplasty and stent - heart - discharge

    Science.gov (United States)

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  5. 经桡动脉冠状动脉支架植入术后的护理%Nursing after via radial artery coronary artery stent implantation

    Institute of Scientific and Technical Information of China (English)

    李少晶

    2016-01-01

    Objective:To explore the postoperative nursing of via radial artery coronary artery stent implantation in the treatment of coronary heart disease.Methods:215 patients with coronary heart disease were given via radial artery coronary artery stent implantation.The postoperative nursing situation was observed.Results:215 patients were successfully completed surgery.2 cases occurred complications after operation,including 1 case of acute myocardial ischemia and 1 case of false aneurysm.They were treated in a timely manner.The patients recovered and discharged.Conclusion:Nursing staff should enhance the understanding,pay attention to the postoperative observation and nursing,systemly master the clinical features,timely find out various problems,report to the doctor,so that they can give timely effective treatment.Through actively taking comprehensive nursing measures is conducive to the patient's recovery as soon as possible,reduce the complications.%目的:探讨经桡动脉冠状动脉内支架植入术治疗冠心病的术后护理。方法:对215例冠心病患者给予经桡动脉冠状动脉内支架植入术,观察术后护理情况。结果:215例患者皆顺利完成手术治疗,术后出现并发症2例,包括急性心肌缺血1例及假性动脉瘤1例,均得到及时处理,患者康复出院。结论:护理人员应提高认识,重视术后的观察及护理,系统掌握其临床特点,及时发现各种问题,报告医生,以便及时、有效地处理,通过积极采取综合护理措施,有利于患者的尽快康复,减少并发症。

  6. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels;

    2013-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...... is a rare, but potential life threatening event after coronary stent implantation. The etiology seems to be multifactorial....

  7. Second- and third-generation drug-eluting coronary stents: progress and safety.

    Science.gov (United States)

    Akin, I; Schneider, H; Ince, H; Kische, S; Rehders, T C; Chatterjee, T; Nienaber, C A

    2011-05-01

    Drug-eluting stents (DES) have revolutionized the treatment of coronary artery disease by reducing the rate of in-stent restenosis from 20-40% with bare-metal stent (BMS) to 6-8% with DES. However, with widespread use of DES, safety concerns have risen due to the observation of late stent thrombosis. With this in mind and better understanding of mechanism and pathophysiology of stent thrombosis, the technological platform, especially innovative anti-restenotic agents, polymeric coatings, and stent platforms, improved with newer DES. Two second-generation DES, the Endeavor zotarolimus-eluting stent (ZES) and the Xience-V everolimus-eluting stent (EES), have provided promising results in both randomized controlled trials (SPIRIT and ENDEAVOR) and registries (E-Five, COMPARE) compared with bare-metal stents (BMS) and first-generation DES. Newer third-generation stent technology, especially biodegradable polymers, polymer-free stents, and biodegradable stents on the basis of poly-L-lactide (PLLA) or magnesium, has been evaluated in preclinical and initial clinical trials. However, despite encouraging initial results, long-term data of large-scale randomized trials as well as registries comparing them to currently approved first- and second-generation DES are still lacking.

  8. Sirolimus-eluting cobalt alloyed stents in treating patients with coronary artery disease: six-month angiographic and one-year clinical follow-up result A prospective, historically controlled, multi-center clinical study

    Institute of Scientific and Technical Information of China (English)

    ZHANG Qi; HONG Tao; CHEN Ji-lin; HUO Yong; SHEN Wei-feng; GAO Run-lin; XU Bo; YANG Yue-jin; ZHANG Rui-yan; LI Jian-ping; QIAO Shu-bin; ZHANG Jian-sheng; HU Jian; QIN Xue-wen

    2007-01-01

    Background The emergence of drug-eluting stents (DES) has dramatically reduced the incidence of in-stent restenosis.This study was conducted to evaluate the safetyand efficacy of sirolimus-eluting cobalt-chrome stents (Firebird 2) for treating patients with coronary artery disease.Methods Sixty-seven patients with de novo or non-stented restenostic coronary lesions were chosen to receive the Firebird 2 stent as the final treatment (Firebird 2 group). Another 49 consecutive patients were implanted with bare cobalt alloyed stents (Driver, Medtronic) withit the previous six months and served as historical controls (control group).Baseline clinical characteristics, angiographic features, procedural results, 30-day, 6-month and 12-month clinical follow-up regarding the occurrence of major adverse cardiac events (MACE), as well as the primary endpoint of late lumen loss at 6-month angiographic follow-up were compared between the two groups.Results The demographic characteristics were similar between the two groups despite more patients in the Firebird 2group who underwent previous percutaneous coronary intervention (22.4% vs 8.2%, P=0.0418) and who had diabetes mellitus (29.9% vs 12.2%, P=0.0253). In the Firebird 2 group, the mean diameter of the reference vessel was smaller((2.79±0.46) mm vs (2.98±0.49) mm, P=0.0175) and more stents were implanted for each lesion (1.28±0.52 vs 1.10±0.30, P=0.0060). Other angiographic, procedural results and the device success rate were similar between the two groups. The MACE rate at 30-day and 3-month was the same, but significantly fewer MACE occurred in the Firebird 2group at 6- and 12-month follow-up (1.5% vs 12.2% at 6 month, P=0.0168; 1.5% vs 26.5% at 12 month, P<0.0001). The primary endpoint of late lumen loss at 6-month angiographic follow-up was significantly reduced in the Firebird 2 group (in-stent: (0.05±0.09) mm vs (0.98±0.61) mm; in-segment: (0.05±0.18) mm vs (0.72±0.59) mm; P<0.0001) than the control group

  9. Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Padayachee, Soundrie [King’s Health Partners, Department of Ultrasonic Angiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Karunanithy, Narayan; Ahmed, Irfan [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Zayed, Hany [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: konstantinos.katsanos@gstt.nhs.uk, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery.

  10. Coronary stent on coronary CT angiography: Assessment with model-based iterative reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Chae; Kim, Yeo Koon; Chun, Eun Ju; Choi, Sang IL [Dept. of of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-05-15

    To assess the performance of model-based iterative reconstruction (MBIR) technique for evaluation of coronary artery stents on coronary CT angiography (CCTA). Twenty-two patients with coronary stent implantation who underwent CCTA were retrospectively enrolled for comparison of image quality between filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and MBIR. In each data set, image noise was measured as the standard deviation of the measured attenuation units within circular regions of interest in the ascending aorta (AA) and left main coronary artery (LM). To objectively assess the noise and blooming artifacts in coronary stent, we additionally measured the standard deviation of the measured attenuation and intra-luminal stent diameters of total 35 stents with dedicated software. All image noise measured in the AA (all p < 0.001), LM (p < 0.001, p = 0.001) and coronary stent (all p < 0.001) were significantly lower with MBIR in comparison to those with FBP or ASIR. Intraluminal stent diameter was significantly higher with MBIR, as compared with ASIR or FBP (p < 0.001, p = 0.001). MBIR can reduce image noise and blooming artifact from the stent, leading to better in-stent assessment in patients with coronary artery stent.

  11. Comparison of drug eluting stent implantation with coronary artery bypass surgery in the treatment of patients with chronic total occlusion and multiple vessel disease

    Institute of Scientific and Technical Information of China (English)

    LIU Wei; ZHU Xiao-Ling; MA Chang-sheng; KANG Jun-ping; DU Xin; CHEN Fang; ZHOU Yu-jie; L(U) Shu-zheng; HUANG Fang-jiong; GU Cheng-xiong

    2011-01-01

    Background In patients with chronic total occlusion (CTO) and multivessel coronary artery disease, the comparison of surgical and the percutaneous revascularization strategies has rarely been conducted. The aim of this study was to compare long term clinical outcomes of drug eluting stent (DES) implantation with coronary artery bypass surgery (CABG)in the patients with CTO and multivessel disease.Methods From a prospective registry of 6000 patients in our institution, we included patients with CTO and multivessel coronary artery disease who underwent either CABG (n=679) or DES (n=267) treatment. Their propensity risk score was used for adjusting baseline differences.Results At a median follow-up of three years, propensity score adjusted Cox regression analysis showed that the rate of major adverse cardiac cerebrovascular events (MACCE) was lower in CABG group (12.7% vs. 24.3%, hazard ratio (HR) 1.969, 95% Cl 1.219-3.179, P=0.006) mainly due to lower rate of target vessel revascularization in CABG group than in DES group (3.1% vs. 17.2%, HR 16.14, 95% CI 5.739-45.391, P <0.001). The incidence of cardiac death or myocardial infarction (composite end point) was not significantly different between these two groups. On multivariate analysis, the significant predictors of MACCE were only the type of revascularization. Age, left ventricular ejection fraction (LVEF), and complete revascularization were identified as significant predictors of composite end points.Conclusions Our study shows that in patients with CTO and multivessel coronary disease, DES can offer comparable long term outcomes in cardiac death and myocardial infraction free survival in comparison with CABG. However, there is an increased rate of MACCE which results from more repeat revascularizations. Obtaining a complete revascularization is crucial for decreasing adverse cardiac events.

  12. A COMPARATIVE STUDY OF PERCUTANEOUS NEPHROSTOMY VERSUS DJ STENTING IN INFECTIVE HYDRONEPHROSIS IN CALCULOUS DISEASE

    Directory of Open Access Journals (Sweden)

    Rammohan

    2015-02-01

    Full Text Available AIMS AND OBJECTIVE: To compare the outcome of percutaneous nephrostomy versus double J ureteral stenting in the management infective hydronephrosis in calculous disease. MATERIALS AND METHODS: From October 2012 to January 2014,40 patients of age 25 - 65 years with obstructing ureteral or renal pelvic stones with clinical signs of infection were underwent decompression by double J stenting(20 patients or percutaneous nephrostomy (20 patients in this study. Patients with single calculus of size less than or equal to 15mm with fever and white blood count (WBC of 14000/ mm 3 or greater were included in this study. Calculus size greater than 15 mm, patients with bilateral or multiple calculi, pregnancy, ureteral or urethral stricture disease, uncorrected coagulopathy, Patients with solitary kidney were excluded from the study. Outcome parameters included time to achieve normal temperature and WBC of 11000 /mm 3 or less, and resolution of pyuria if present were analyzed in both group of patients. RESULTS: Majority of the patients were between 25 to 65 years of age with male to female ratio was2.12:2.87.The most common location of stone was at distal ureter in either group. There was no significant difference between pre procedural WBC count, maximum temperature and stone size in either group. Procedura land fluoroscopy times were significantly shorter for double j stenting (30.95±6.02 and5.3±3.2 compared with percutaneous nephrostomy (35.9± 5.4 and7.2± 4.2. During drainage the appearance of the urine was grossly purulent in 5 patients (12.5%, turbid in 19 (47.5% and clear in 16 (40%. Overall urine cultures and blood cultures were positive in 50 and 12.5% of patients, respectively. Urine cultures were positive in 60% of the percutaneous nephrostomy compared with 40% of the double j stenting group (p not significant. There was no significant difference in time to clinical improvement (T ime to normal WBC and temperature and time for purulent drain

  13. Cavernous carotid artery pseudo-aneurysm treated by stenting in acromegalic patient Pseudoaneurisma da artéria carótida cavernosa tratado com "stent" em paciente acromegálica

    Directory of Open Access Journals (Sweden)

    Jorge Marcondes de Souza

    2003-06-01

    Full Text Available We report on a case of endovascular management of pseudoaneurysm of the cavernous segment of the internal carotid artery with covered stent reconstruction. A 36 years-old woman with a history of previous transsphenoidal approach for pituitary macroadenoma and false aneurysma formation was studied in a protocol that included balloon test occlusion and cerebral blood flow evaluation. An endovascular covered stent deployment in the area of the carotid laceration was performed with isolation of the aneurysm from the circulation and maintenance of the carotid flow. Helical angio-CT and cerebral digital subtraction angiography showed the carotid preservation without stenosis in the stented area. In conclusion, endovascular stent reconstruction for post-transsphenoidal carotid artery laceration and false aneurysm is demonstrated as useful technical adjunct in the management strategy and with the potential for carotid sacrifice morbidity avoidance.Relatamos um caso de manuseio com "stent" recoberto por pseudoaneurisma do segmento cavernoso da artéria carótida interna. A paciente de 36 anos, tinha história de cirurgia trans-esfenoidal para macroadenoma de hipófise e desenvolvimento de falso aneurisma na região cavernosa da ACI, foi estudado com protocolo para avaliação de reserva circulatória carotídea com teste de oclusão por balão e estudo de fluxo sanguíneo cerebral com tomografia computorizada de emissão de fóton único (SPECT. Instalação de "stent" recoberto no segmento lesado isolou o aneurisma da circulação, com manutenção do fluxo carotídeo. Angio-tomografia helicoidal e angiografia digital por subtração demonstraram a reconstrução carotídea sem estenose local. Em conclusão, reconstrução carotídea com "stent" recoberto é possível na estratégia para manuseio de pseudo-aneurisma com potencial para prevenção da morbidade do sacrifício terapêutico carotídeo.

  14. One year cost effectiveness of sirolimus eluting stents compared with bare metal stents in the treatment of single native de novo coronary lesions: an analysis from the RAVEL trial

    Science.gov (United States)

    van Hout, B A; Serruys, P W; Lemos, P A; van den Brand, M J B M; Es, G-A van; Lindeboom, W K; Morice, M-C

    2005-01-01

    Objective: To assess the balance between costs and effects of the sirolimus eluting stent in the treatment of single native de novo coronary lesions in the RAVEL (randomised study with the sirolimus eluting Bx Velocity balloon expandable stent in the treatment of patients with de novo native coronary artery lesions) study. Design: Multicentre, double blind, randomised trial Setting: Percutaneous coronary intervention for single de novo coronary lesions Patients: 238 patients with stable or unstable angina. Interventions: Randomisation to sirolimus eluting stent or bare stent implantation. Main outcome measures: Patients were followed up to one year and the treatment effects were expressed as one year survival free of major adverse cardiac events (MACE). Costs were estimated as the product of resource utilisation and Dutch unit costs. Results: At one year, the absolute difference in MACE-free survival was 23% in favour of the sirolimus eluting stent group. At the index procedure, sirolimus eluting stent implantation had an estimated additional procedural cost of €1286. At one year, however, the estimated additional cost difference had decreased to €54 because of the reduction in the need for repeat revascularisations in the sirolimus group (0.8% v 23.6%; p < 0.01). After adjustment of actual results for the consequences of angiographic follow up (correction based on data from the BENESTENT (Belgium Netherlands stent) II study), the difference in MACE-free survival was estimated at 11.1% and the additional one year costs at €166. Conclusions: The one year data from RAVEL suggest an attractive balance between costs and effects for sirolimus eluting stents in the treatment of single native de novo coronary lesions. The cost effectiveness of drug eluting stents in more complex lesion subsets remains to be determined. PMID:15772214

  15. Biocompatibility of coronary stent materials: effect of electrochemical polishing

    Energy Technology Data Exchange (ETDEWEB)

    Scheerder, I. de [University Hospital Leuven (Belgium). Dept. of Cardiology; Sohier, J.; Froyen, L.; Humbeeck, J. van [Louvain Univ. (Belgium). Dept. of Metallurgy and Materials Engineering; Verbeken, E. [University Hospital Leuven (Belgium). Dept. of Pathology

    2001-02-01

    Percutaneous Transluminal Coronary Revascularization (PTCR) is now a widely accepted treatment modality for atherosclerotic coronary artery disease. Current multicenter randomized trials comparing PTCR with the more invasive Coronary Artery Bypass Grafting could not show long-term significant survival differences. During the last two decades progress has been made to further optimize PTCR. The most logic approach to treat atherosclerotic coronary narrowings is to remove the atherosclerotic material using especially developed devices. Several trials, however, could not show a significant beneficial outcome after use of these devices compared to plain old balloon angioplasty. Another approach was to implant a coronary prothesis (stent), scaffolding the diseased coronary artery after PTCA. This approach resulted in a decreased restenosis rate at follow-up. The beneficial effects of stenting, however, was not found to be related to the inhibition of the neointimal cellular proliferation after vascular injury, but simply to be the mechanical result of overstretching of the treated vessel segment. The most important remaining clinical problem after stenting remains the neointimal hyperplasia within the stent, resulting in a significant stent narrowing in 13 to 30% of patients. Further efforts to improve the clinical results of coronary stenting should focus on the reduction of this neointimal hyperplasia. Neointimal hyperplasia after stent implantation results from (1) a healting response to the injury caused by the stent implantation and (2) a foreign body response to the stent itself. Factors that seem to influence the neointimal hyperplastic response are genetic, local disease related, stent delivery related and stent related factors. Biocompatibilisation of coronary stents by looking for more biocompatible metal alloys, optimized surface characteristics and optimized stent designs should result in a better late patency. Furthermore drug eluting and radioactive stents

  16. Investigation of the dynamic diameter deformation of vascular stents during fatigue testing with radial loading

    Directory of Open Access Journals (Sweden)

    Boeck Maria

    2015-09-01

    Full Text Available Endovascular stents are exposed to cyclic loads resulting from daily activity and pulsatile arterial blood pressure. DIN EN ISO 25539-2 and FDA guideline 1545 recommend durability testing, exposing stents to physiological cyclic loads for a 10 year equivalent. For accelerated testing, the simulated deformation has to be comparable to physiological in-vivo deformation. A new test setup is presented to determine diameter deformation of vascular stents during fatigue testing with radial loading.

  17. The next generation of drug-eluting stents: What's on the horizon?

    NARCIS (Netherlands)

    S. Ramcharitar (Steve); S. Vaina (Sophia); P.W.J.C. Serruys (Patrick)

    2007-01-01

    textabstractDrug-eluting stents have radically changed the way we treat coronary artery disease. They offer lower restenotic rates compared with the bare metal stents and this enables more challenging and complex lesions to be treated. However, there are still limitations as restenosis has not been

  18. The Relationships between Polymorphisms in Genes Encoding the Growth Factors TGF-β1, PDGFB, EGF, bFGF and VEGF-A and the Restenosis Process in Patients with Stable Coronary Artery Disease Treated with Bare Metal Stent.

    Directory of Open Access Journals (Sweden)

    Tadeusz Osadnik

    Full Text Available Neointima forming after stent implantation consists of vascular smooth muscle cells (VSMCs in 90%. Growth factors TGF-β1, PDGFB, EGF, bFGF and VEGF-A play an important role in VSMC proliferation and migration to the tunica intima after arterial wall injury. The aim of this paper was an analysis of functional polymorphisms in genes encoding TGF-β1, PDGFB, EGF, bFGF and VEGF-A in relation to in-stent restenosis (ISR.265 patients with a stable coronary artery disease (SCAD hospitalized in our center in the years 2007-2011 were included in the study. All patients underwent stent implantation at admission to the hospital and had another coronary angiography performed due to recurrence of the ailments or a positive result of the test assessing the coronary flow reserve. Angiographically significant ISR was defined as stenosis >50% in the stented coronary artery segment. The patients were divided into two groups-with angiographically significant ISR (n = 53 and without significant ISR (n = 212. Additionally, the assessment of late lumen loss (LLL in vessel was performed. EGF rs4444903 polymorphism was genotyped using the PCR-RFLP method whilst rs1800470 (TGFB1, rs2285094 (PDGFB rs308395 (bFGF and rs699947 (VEGF-A were determined using the TaqMan method.Angiographically significant ISR was significantly less frequently observed in the group of patients with the A/A genotype of rs1800470 polymorphism (TGFB1 versus patients with A/G and G/G genotypes. In the multivariable analysis, LLL was significantly lower in patients with the A/A genotype of rs1800470 (TGFB1 versus those with the A/G and G/G genotypes and higher in patients with the A/A genotype of the VEGF-A polymorphism versus the A/C and C/C genotypes. The C/C genotype of rs2285094 (PDGFB was associated with greater LLL compared to C/T heterozygotes and T/T homozygotes.The polymorphisms rs1800470, rs2285094 and rs6999447 of the TGFB1, PDGFB and VEGF-A genes, respectively, are associated with LLL

  19. Self-Expandable Stent for Repairing Coarctation of the Left-Circumferential Aortic Arch with Right-sided Descending Aorta and Aberrant Right Subclavian Artery with Kommerell's Aneurysm.

    Science.gov (United States)

    Khajali, Zahra; Sanati, Hamid Reza; Pouraliakbar, Hamidreza; Mohebbi, Bahram; Aeinfar, Kamran; Zolfaghari, Reza

    2017-01-01

    Endovascular treatment offers a great advantage in the management of main arteries stenoses. However, simultaneous presence of a group of anomalies may complicate the situation. Here we present a case of 21-year-old man with aortic coarctation. Radiographic imaging and angiography demonstrated aortic coarctation of the left-circumferential aortic arch, right-sided descending aorta, and Kommerell's diverticulum at the origin of right subclavian artery. These anomalies have rarely been reported to concurrently exist in the same case and the treatment is challenging. Percutaneous treatment for repair of aortic coarctation was successfully performed with deployment of self-expanding nitinol stents. Follow-up demonstrated the correction of blood pressure and improvement of the symptoms. It appears that deployment of self-expandable nitinol stents present a viable option for the management of coarcted aorta in patients having all or some of these anomalies together.

  20. Time-Resolved 3D Contrast-Enhanced MRA on 3.0T: a Non-Invasive Follow-Up Technique after Stent-Assisted Coil Embolization of the Intracranial Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Roh, Hong Gee; Moon, Won Jin; Kim, Na Ra; Moon, Sung Gyu; Kang, Chung Hwan; Chun, Young Il; Kang, Hyun Seung [University College of Medicine, Seoul (Korea, Republic of)

    2011-11-15

    To evaluate the usefulness of time-resolved contrast enhanced magnetic resonance angiography (4D MRA) after stent-assisted coil embolization by comparing it with time of flight (TOF)-MRA. TOF-MRA and 4D MRA were obtained by 3T MRI in 26 patients treated with stent-assisted coil embolization (Enterprise:Neuroform = 7:19). The qualities of the MRA were rated on a graded scale of 0 to 4. We classified completeness of endovascular treatment into three categories. The degree of quality of visualization of the stented artery was compared between TOF and 4D MRA by the Wilcoxon signed rank test. We used the Mann-Whitney U test for comparing the quality of the visualization of the stented artery according to the stent type in each MRA method. The quality in terms of the visualization of the stented arteries in 4D MRA was significantly superior to that in 3D TOF-MRA, regardless of type of the stent (p < 0.001). The quality of the arteries which were stented with Neuroform was superior to that of the arteries stented with Enterprise in 3D TOF (p < 0.001) and 4D MRA (p = 0.008), respectively. 4D MRA provides a higher quality view of the stented parent arteries when compared with TOF.

  1. Endovascular Gene Delivery from a Stent Platform: Gene- Eluting Stents.

    Science.gov (United States)

    Fishbein, Ilia; Chorny, Michael; Adamo, Richard F; Forbes, Scott P; Corrales, Ricardo A; Alferiev, Ivan S; Levy, Robert J

    A synergistic impact of research in the fields of post-angioplasty restenosis, drug-eluting stents and vascular gene therapy over the past 15 years has shaped the concept of gene-eluting stents. Gene-eluting stents hold promise of overcoming some biological and technical problems inherent to drug-eluting stent technology. As the field of gene-eluting stents matures it becomes evident that all three main design modules of a gene-eluting stent: a therapeutic transgene, a vector and a delivery system are equally important for accomplishing sustained inhibition of neointimal formation in arteries treated with gene delivery stents. This review summarizes prior work on stent-based gene delivery and discusses the main optimization strategies required to move the field of gene-eluting stents to clinical translation.

  2. Increase of ADAM10 level in coronary artery in-stent restenosis segments in diabetic minipigs: high ADAM10 expression promoting growth and migration in human vascular smooth muscle cells via Notch 1 and 3.

    Directory of Open Access Journals (Sweden)

    Ke Yang

    Full Text Available BACKGROUND: This study aimed to identify major proteins in the pathogenesis of coronary artery in-stent restenosis (ISR in diabetic minipigs with sirolimus-eluting stenting, and to investigate the roles of key candidate molecules, particularly ADAM10, in human arterial smooth muscle cells (HASMCs. METHODS AND RESULTS: The stents were implanted in the coronary arteries of 15 diabetic and 26 non-diabetic minipigs, and angiography was repeated at six months. The intima of one vascular segment with significant ISR and one with non-ISR in diabetic minipigs were isolated and cultured in conditioned medium (CM. The CM was analyzed by LC-MS/MS to uncover proteins whose levels were significantly increased (≥ 1.5-fold in ISR than in non-ISR tissues. After literature searching, we focused on the identified proteins, whose biological functions were most potentially related to ISR pathophysiology. Among them, ADAM10 was significantly increased in diabetic and non-diabetic ISR tissues as compared with non-ISR controls. In cell experiments, retrovirus-mediated overexpression of ADAM10 promoted growth and migration of HASMCs. The effects of ADAM10 were more remarkable in high-glucose culture than in low-glucose culture. Using shRNA and an inhibitor of γ-secretase (GSI, we found that the influences of ADAM10 were in part mediated by Notch1 and notch 3 pathway, which up-regulated Notch downstream genes and enhanced nuclear translocation of the small intracellular component of Notch1 and Notch3. CONCLUSIONS: This study has identified significantly increased expression of ADAM10 in the ISR versus non-ISR segment in diabetic minipigs and implicates ADAM10 in the enhanced neointimal formation observed in diabetes after vascular injury.

  3. Hemodynamics of Stent Implantation Procedures in Coronary Bifurcations: an in vitro study

    CERN Document Server

    Brindise, Melissa C; Burzotta, Francesco; Migliavacca, Francesco; Vlachos, Pavlos P

    2016-01-01

    Stent implantation in coronary bifurcations presents unique challenges and currently there is no universally accepted stent deployment approach. Despite clinical and computational studies, to date, the effect of each stent implantation method on the coronary artery hemodynamics is not well understood. In this study the hemodynamics of stented coronary bifurcations under pulsatile flow conditions were investigated experimentally. Three implantation methods, provisional side branch (PSB), culotte (CUL), and crush (CRU), were investigated using time-resolved particle image velocimetry (PIV) to measure the velocity fields. Subsequently, hemodynamic parameters including wall shear stress (WSS), oscillatory shear index (OSI), and relative residence time (RRT) were calculated and the pressure field through the vessel was non-invasively quantified. The effects of each stented case were evaluated and compared against an un-stented case. CRU provided the lowest compliance mismatch, but demonstrated detrimental stent in...

  4. [On evaluating occupational fitness in railway workers with ventricular arrhythmias after coronary arteries stenting].

    Science.gov (United States)

    Muraseyeva, E V; Gorokhova, S G; Prigorovskaya, T S; Pfaf, V F

    2016-01-01

    The authors studied prospects of work capacity preserving after coronary stenting in IHD and cardiac arrhythmias. Examination covered 158 railway workers underwent complete endovascular revascularization of myocardium for coronary stenosis; all of them had ventricular arrhythmias before coronary surgery. Findings are that in long-term period (in 16 months in average) after coronary stenting, grade I and III ventricular extrasystoles disappeared in 77.8 and 54.5% of cases respectively, but only in 11.9% of grade IV ventricular extrasystoles cases. Ventricular extrasystoles remained unchanged in 44.3% of cases. Reliable relationships were seen between unchanged grade IV ventricular extrasystoles and body weight index (OR = 5.49, 95% CI: 0.87-34.67), general cholesterol level (OR = 1.69; 95% CI: 1.06-2.69), low density lipoproteins (OR = 1.66; 95% CI: 1.00-2.76) and left ventricular ejection function lower 45% (OR = 1.61; 95% CI: 1.14-2.27), exertion ventricular extrasystoles before myocardium revascularization (OR = 3.1; 95% CI: 1.78-5.41). That necessitates correction of the mentioned risk factors of cardiac arrhythmias for restored work capacity.

  5. Supera self-expanding stents for endovascular treatment of femoropopliteal disease: a review of the clinical evidence

    Directory of Open Access Journals (Sweden)

    Bishu K

    2015-07-01

    Full Text Available Kalkidan Bishu,1,2 Ehrin J Armstrong1,21Division of Cardiology, University of Colorado, Aurora, 2Denver VA Medical Center, Denver, CO, USAAbstract: Femoropopliteal lesions account for a significant proportion of endovascular interventions for peripheral artery disease in patients with disabling claudication or chronic limb ischemia. The femoropopliteal artery crosses two joint structures (hip and knee joints and courses through the muscular adductor canal in the thigh, which places the artery at increased biomechanical stress. There is a critical need for stent platforms with a reduced risk of stent fracture while maintaining patency during long-term follow-up. The Supera peripheral stent system has a braided nickel–titanium alloy stent designed to withstand the unique stressors along the course of the femoropopliteal artery. This design may be associated with improved patency in association with reduced stent fracture rates on short- and medium-term follow-up. Further studies, including randomized controlled studies, comparing the Supera interwoven nickel–titanium alloy stent system with other stent platforms and angioplasty alone are needed.Keywords: peripheral artery disease, femoropopliteal atherosclerosis, SUPERA interwoven nitinol stent, stent fracture

  6. Traumatic aneurysm of the supraclinoid internal carotid artery and an associated carotid-cavernous fistula: vascular reconstruction performed using intravascular implantation of stents and coils. Case report.

    Science.gov (United States)

    Lee, Chang-Young; Yim, Man-Bin; Kim, Il-Man; Son, Eun-Ik; Kim, Dong-Won

    2004-01-01

    This report documents the treatment of a traumatic aneurysm of the supraclinoid internal carotid artery (ICA) that was associated with a carotid-cavernous fistula (CCF), which appeared following closed head trauma. This life-threatening lesion, which is very rare, required aggressive management achieved using intravascular stents and coils. A 19-year-old man presented with severe traumatic intracerebral and subarachnoid hematoma after he had suffered a severe closed head injury in a motor vehicle accident. Cerebral angiography performed 11 days after the injury demonstrated a traumatic aneurysm and severe narrowing of the right supraclinoid ICA, which was consistent with a dissection-induced stenosis associated with a direct CCF. Both lesions were successfully obliterated with preservation of the parent artery by using stents in conjunction with coils. Follow-up angiography obtained 7 months postoperatively revealed persistent obliteration of the aneurysm and CCF as well as patency of the parent artery. The patient remained asymptomatic during the clinical follow-up period of 14 months. Endovascular treatment involving the use of a stent combined with coils appears to be a feasible, minimally invasive option for treatment of this hard-to-treat lesion.

  7. Comparison between Carotid Stenting and Carotid Endarterectomy in Early Outcome

    OpenAIRE

    Kovačić, Slavica; Kovačević, Miljenko; Strenja-Linić, Ines; Budiselić, Berislav; Knežević, Siniša

    2011-01-01

    Carotid artery stenting (CAS) is a widely used method in prevention of stroke for carotid artery stenosis as an alternative to surgical treatment. Initial studies reveal higher morbidity and mortality rates for CAS than acceptable standards for carotid endarterectomy (CEA). The aim of this study was to compare results in a series of CAS with concurrent risk-matched group of CEA patients. The study included two groups of 50 patients with internal carotid artery stenosis. We compare...

  8. Direct coronary stent implantation: safety, feasibility, and predictors of success of the strategy of direct coronary stent implantation.

    Science.gov (United States)

    Laarman, G; Muthusamy, T S; Swart, H; Westendorp, I; Kiemeneij, F; Slagboom, T; van der Wieken, R

    2001-04-01

    This prospective study was designed to evaluate the feasibility, safety, predictive factors of success, and 6-month follow-up of stent implantation without balloon predilatation (direct stenting) in 250 patients undergoing elective stent implantation. Balloon dilatation prior to stent implantation was a prerequisite to facilitate passage and deployment of the stent. Stent technology has changed tremendously, resulting in stents with improved properties, which may allow stent placement without prior balloon dilatation. Patients with coronary lesions suitable for elective stent implantation were included in this trial. Coronary interventions were undertaken predominantly via the transradial route using 6 Fr guiding catheters. Direct stent implantation was attempted using AVE GFX II coronary stent delivery systems. Upon failure, predilatation was undertaken before reattempting stent implantation. Patient data and ECGs were obtained from case records and from personal or telephone interviews 6 months after the procedure. Values were presented as mean +/- standard deviation. Student's t-test, two-tailed at 5% level of significance, was used to compare the difference of two means. Multivariate logistic regression analysis was performed to establish predictive factors for failure of direct stenting. Two hundred and sixty-six direct stent implantations were attempted in 250 patients. Direct stenting was successful in 226 (85%) cases. Out of 40(15%) cases where direct stenting failed, balloon predilatation facilitated stent implantation in 39. In one lesion, stent implantation was not possible despite adequate predilatation. Predictive factors for failure of direct stenting on multivariate analysis were LCx lesions (P < 0.01), complex lesions (P < 0.01), and longer stents (P < 0.001). Minimal luminal diameter and percentage diameter stenosis of lesions in the successful and the failure group were not significantly different (0.94 +/- 0.39 mm vs. 0.84 +/- 0.41 mm, P = NS

  9. Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model

    Directory of Open Access Journals (Sweden)

    Yizhe Wu

    2012-01-01

    Full Text Available Objective. To investigate acute recoil of bioabsorbable poly-L-lactic acid (PLLA stent. Background. As newly developed coronary stent, bioabsorbable PLLA stent still encountered concern of acute stent recoil. Methods. Sixteen minipigs were enrolled in our study. Eight PLLA XINSORB stents (Weite Biotechnology Co., Ltd., China and eight metallic stents (EXCEL, Jiwei Co., Ltd. China were implanted into coronary arteries. Upon quantitative coronary angiography analysis, acute absolute recoil was defined as the difference between mean diameter of inflated balloon (X and mean lumen diameter of stent immediately after deployment (Y, while acute percent recoil was defined as (X−Y/X and expressed as a percentage. Intravascular ultrasound (IVUS was performed immediately after implantation and 24 hours later to compare cross-sectional area (CSA between two groups and detect stent malapposition or collapse. Results. Acute absolute recoil in XINSORB and EXCEL was 0.02±0.13 mm and −0.08±0.08 mm respectively (P=0.19. Acute percent recoil in XINSORB and EXCEL was 0.66±4.32% and −1.40±3.83%, respectively (P=0.45. CSA of XINSORB was similar to that of EXCEL immediately after implantation, so was CSA of XINSORB at 24-hours followup. Within XINSORB group, no difference existed between CSA after implantation and CSA at 24-hours followup. No sign of acute stent malapposition was detected by IVUS. Conclusions. The acute stent recoil of XINSORB is similar to that of EXCEL. No acute stent malapposition or collapse appeared in both kinds of stent. This preclinical study was designed to provide preliminary data for future studies of long-term efficacy and safety of XINSORB stent.

  10. Treatment of intracranial aneurysms. Reconstruction of the parent artery with flow-diverting (Silk) stent

    DEFF Research Database (Denmark)

    Wagner, Aase; Cortsen, Marie; Hauerberg, John

    2011-01-01

    INTRODUCTION: Since the flow diverters (FDs) have been introduced it is possible to treat aneurysms that are considered difficult or impossible to treat with usual endovascular or surgical methods. It is still uncertain which aneurysms are suitable for this new treatment. We present...... the periprocedural complications, immediate result, late complications, imaging follow-up at 6 and 12 months and clinical follow-up at 2-23 months. METHODS: Twenty-two patients with 26 wide-necked or blister-like aneurysms had 23 treatments with implantation of a Silk stent. Eleven patients had re......-canalizations, and 11 patients were either untreated or had been treated for another aneurysm. RESULTS: Periprocedural complications were seen in four treatments (17%). However, none of these had clinical consequences. Mortality and morbidity rates were 1 of 22 (5%) and 1 of 22 (5%), respectively. Clinical outcome...

  11. Grade III Coronary Artery Perforation Following PCI and Unusual Stent Graft Delivery System

    Directory of Open Access Journals (Sweden)

    Sreckovic Miodrag

    2014-06-01

    Full Text Available Koronarne perforacije su retke ali izuzetno neugodne komlikacije perkutanih intervencija. Perforacije koronarnh arterija trećeg stepena po Elisu predstvaljaju najozbiljniju formu perforacija i zahtevaju hitno zbrinjavanje. Često je neophodno uraditi perikardiocentezu i primeniti brojne interventne tehnike kako bismo rešili perforaciju. Stentovi prekriveni politetrafluoroetilenom(PTFE postali su jedno od najčešće korišćenih perkutanih rešenja, ali su njihove mane visoki profil i slaba fleksibilnost. U našem slučaju, pokušali smo da poboljšamo plasiranje PTFE stenta montiranjem na metalni stent, koji smo iskoristili kao nosač.

  12. Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents: A Multivariable Statistical Analysis.

    Science.gov (United States)

    Martin, David; Boyle, Fergal

    2015-09-01

    Several clinical studies have identified a strong correlation between neointimal hyperplasia following coronary stent deployment and both stent-induced arterial injury and altered vessel hemodynamics. As such, the sequential structural and fluid dynamics analysis of balloon-expandable stent deployment should provide a comprehensive indication of stent performance. Despite this observation, very few numerical studies of balloon-expandable coronary stents have considered both the mechanical and hemodynamic impact of stent deployment. Furthermore, in the few studies that have considered both phenomena, only a small number of stents have been considered. In this study, a sequential structural and fluid dynamics analysis methodology was employed to compare both the mechanical and hemodynamic impact of six balloon-expandable coronary stents. To investigate the relationship between stent design and performance, several common stent design properties were then identified and the dependence between these properties and both the mechanical and hemodynamic variables of interest was evaluated using statistical measures of correlation. Following the completion of the numerical analyses, stent strut thickness was identified as the only common design property that demonstrated a strong dependence with either the mean equivalent stress predicted in the artery wall or the mean relative residence time predicted on the luminal surface of the artery. These results corroborate the findings of the large-scale ISAR-STEREO clinical studies and highlight the crucial role of strut thickness in coronary stent design. The sequential structural and fluid dynamics analysis methodology and the multivariable statistical treatment of the results described in this study should prove useful in the design of future balloon-expandable coronary stents.

  13. When stenting in renal artery stenosis? Update on pathophysiology of ischemic nephropathy and management strategies

    Directory of Open Access Journals (Sweden)

    Alessandro Zuccalà

    2013-11-01

    Full Text Available In recent years, decisions taken on the optimal management of patients with renal artery stenosis have triggered off controversy and debate among clinicians dealing with renovascular disease. The main reason underlying this ongoing controversy may be the heterogeneity of the clinical entities that are normally associated with the umbrella definition of renal artery stenosis. Indeed a causal link between the stenosis and its clinical consequences (i.e. hypertension, renal failure can often demonstrated in some entities, such as fibromuscular dysplasia, truncal stenosis or arterial stenosis in the transplanted kidney, which can be defined as pure renal artery stenosis. On the contrary, the entity generally called ostial stenosis is a disease of the abdominal aorta where it encroaches the ostium of the renal artery at the end of a long process involving the entire vascular tree. Patients affected by ostial stenosis also suffer from generalized atherosclerosis, and kidney damage is often caused by the atherosclerotic environment with the stenosis acting as an innocent bystander. This may account for the low rate of renal function recovery in subjects with ostial stenosis. In our view, keeping the different entities separate along with a careful understanding of the mechanisms underpinning renal damage, particularly the intrarenal activation of the renin angiotensin system which in turn induces renal inflammation and oxidative stress, may enable clinicians to make the right decisions in regard to revascularization.

  14. Impact of diabetes on the benefits from everolimus-eluting stent as compared to first-generation drug-eluting stent in patients with ST elevation myocardial infarction

    NARCIS (Netherlands)

    Luca, G. De; Sauro, R.; Capasso, M.; Lanzillo, T.; Manganelli, F.; Carbone, G.; Lanni, F.; Pagliuca, M.R.; Palmieri, V.; Serino, V.; Rosato, G.; Suryapranata, H.; Lorenzo, E. Di

    2015-01-01

    BACKGROUND: Drug-eluting stent has been shown to reduce the risk of repeated revascularization. However, as shown for first-generation drug-eluting stent, they may be counterbalanced by a potential higher risk of stent thrombosis, especially among ST-segment elevation myocardial infarction patients.

  15. Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis; Erste Erfahrungen mit einem Monorail-Stent-Ballon-System zur endovaskulaeren Behandlung von Nierenarterienstenosen

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Huelsbeck, S.; Jahnke, T.; Grimm, J.; Behm, C.; Hilbert, C.; Frahm, C.; Biederer, J.; Brossmann, J.; Heller, M. [Kiel Univ. (Germany). Klinik fuer Diagnostische Radiologie

    2002-03-01

    Objective: To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). Patients and Methods: During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink{sup TM} 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfermoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88% {+-}10 and 9 mm {+-}5. Results: Renal stent implantation was technically successful in all cases (100%). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg {+-} 10 before to 1 mmHg {+-} 1.8 after the procedure. Remaining stenosis measured 0.7% {+-}4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n.s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p <0.0001) after the intervention. Primary and secondary patency rates at 6 months were 72% (Standard Error 9.8%) and 77% (Standard Error 9.2%), respectively. Conclusion: With the used monorail-stend-balloon device a technically easy, secure and exact renal stent placement is guaranteed, patency rates are similar to those described in the current literature. (orig.) [German] Ziel: Bestimmung der Wertigkeit eines Monorail-Stent-Ballon-Systems zur Behandlung von Nierenarterienstenosen (NAS). Patienten und Methode: Waehrend eines Zeitraumes von 18 Monaten wurden bei 38 Patienten 41 NAS (Hypertonus n = 36, renale Insuffizienz n = 18) mit Indikationen zur renalen Stentimplantation (kalzifizierte Ostiumlaesion n = 35, insuffiziente PTA n = 4, Dissektion n = 2) in die prospektive Untersuchung einbezogen. Vormontierte Stents wurden (Rx-Herculink{sup TM} 5 mm = 13, 6 mm = 34, 7 mm = 1) ueber einen

  16. Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn-Alloys.

    Science.gov (United States)

    Bowen, Patrick K; Shearier, Emily R; Zhao, Shan; Guillory, Roger J; Zhao, Feng; Goldman, Jeremy; Drelich, Jaroslaw W

    2016-05-01

    Metallic stents are used to promote revascularization and maintain patency of plaqued or damaged arteries following balloon angioplasty. To mitigate the long-term side effects associated with corrosion-resistant stents (i.e., chronic inflammation and late stage thrombosis), a new generation of so-called "bioabsorbable" stents is currently being developed. The bioabsorbable coronary stents will corrode and be absorbed by the artery after completing their task as vascular scaffolding. Research spanning the last two decades has focused on biodegradable polymeric, iron-based, and magnesium-based stent materials. The inherent mechanical and surface properties of metals make them more attractive stent material candidates than their polymeric counterparts. A third class of metallic bioabsorbable materials that are based on zinc has been introduced in the last few years. This new zinc-based class of materials demonstrates the potential for an absorbable metallic stent with the mechanical and biodegradation characteristics required for optimal stent performance. This review compares bioabsorbable materials and summarizes progress towards bioabsorbable stents. It emphasizes the current understanding of physiological and biological benefits of zinc and its biocompatibility. Finally, the review provides an outlook on challenges in designing zinc-based stents of optimal mechanical properties and biodegradation rate.

  17. The cognitive function changes of patients accepted carotid artery stenting in postoperative different period%颈动脉支架置入患者术后不同时期的认知功能变化

    Institute of Scientific and Technical Information of China (English)

    王雁; 孙涛

    2011-01-01

    目的 探讨颈动脉支架置入(CAS)患者术后不同时期的认知功能变化及其可能机制.方法 选取76例接受CAS的颈动脉狭窄患者(病例组)和63例接受冠脉支架置入术的冠心病患者(对照组)作为研究对象,所有患者术前行DSA检查,分别在支架置入术前及术后3 d、10个月,应用蒙特利尔认知评估量表对患者进行认知评估.结果 病例组术后3 d与术前比较,MoCA总分、交替连线试验,复制立方体、画钟、注意力、延迟回忆测评得分降低,具有显著性差异;术后10个月与术前比较,注意力、延迟回忆测评得分升高,差异具有显著性;术后3 d与术后10个月比较,MoCA总分、交替连线试验、复制立方体、画钟、注意力、延迟回忆测评得分的差异均有显著性.病例组与对照组比较,术前、术后3 d的注意力、延迟回忆测评得分差异有显著性.结论 颈动脉狭窄置入术可最终改善注意力和延迟回忆功能.术后早期可出现暂时的、可逆的认知功能恶化,但认知功能在远期多会改善.%Objective To investigate the changes of cognitive function in different period after carotid artery stenting and explore the related mechanism of cognitive changes. Methods 76 carotid stenosis patients were treated with carotid artery stenting and 63 patients were given coronary artery stenting ( control group) as subjects. All patients were accepted DSA, and respectively were tested with montreal cognitire assessment at preoperative and third day, tenth month after stenting. Results Compared postoperative third day with preoperative cognitive function, cognitive test scores including MoCA total score, Trial Making B task, three-dimensional cube copy, clock-drawing task, attention, and delayed recall had significantly declined. Compared postoperative tenth month with preoperative, cognitive test scores including attention, and delayed recall were significantly improved. Compared postoperative

  18. Very late coronary aneurysm formation with subsequent stent thrombosis secondary to drug-eluting stent

    Institute of Scientific and Technical Information of China (English)

    Ibrahim Akin,; Stephan Kische; Tim C Rehders; Henrik Schneider; G(o)kmen R Turan; Tilo Kleinfeldt; Jasmin Ortak; Christoph A. Nienaber; Hüseyin Ince

    2011-01-01

    Drug-eluting stents have changed the practice in interventional cardiology.With the widespread use of these stents important safety concerns regarding stent thrombosis and formation of coronary artery aneurysm have been expressed.While the majority of attention was focused on stent thrombosis,the formation of coronary aneurysm was only described in anecdotal reports.We report on a patient who suffered from very late stent thrombosis in association with coronary artery aneurysm formation secondary to drug-eluting stent but not to bare-metal stent.

  19. Biological behaviour of human umbilical artery smooth muscle cell grown on nickel-free and nickel-containing stainless steel for stent implantation

    Science.gov (United States)

    Li, Liming; An, Liwen; Zhou, Xiaohang; Pan, Shuang; Meng, Xin; Ren, Yibin; Yang, Ke; Guan, Yifu

    2016-01-01

    To evaluate the clinical potential of high nitrogen nickel-free austenitic stainless steel (HNNF SS), we have compared the cellular and molecular responses of human umbilical artery smooth muscle cells (HUASMCs) to HNNF SS and 316L SS (nickel-containing austenitic 316L stainless steel). CCK-8 analysis and flow cytometric analysis were used to assess the cellular responses (proliferation, apoptosis, and cell cycle), and quantitative real-time PCR (qRT-PCR) was used to analyze the gene expression profiles of HUASMCs exposed to HNNF SS and 316L SS, respectively. CCK-8 analysis demonstrated that HUASMCs cultured on HNNF SS proliferated more slowly than those on 316L SS. Flow cytometric analysis revealed that HNNF SS could activate more cellular apoptosis. The qRT-PCR results showed that the genes regulating cell apoptosis and autophagy were up-regulated on HNNF SS. Thus, HNNF SS could reduce the HUASMC proliferation in comparison to 316L SS. The findings furnish valuable information for developing new biomedical materials for stent implantation.

  20. Long-term safety and efficacy of percutaneous coronary intervention with stenting and coronary artery bypass surgery for multivessel coronary artery disease: A meta-analysis with 5-year patient-level data from the ARTS, ERACI-II, MASS-II, and SoS trials

    NARCIS (Netherlands)

    J. Daemen (Joost); H. Boersma (Eric); M. Flather (Marcus); J. Booth (Jean); R.H. Stables (Rodney); A. Rodriguez (Alfredo Chapin); G.A. Rodriguez-Granillo (Gaston); W.A. Hueb (Whady Armindo); P.A. Lemos Neto (Pedro); P.W.J.C. Serruys (Patrick)

    2008-01-01

    textabstractBackground - Randomized trials that studied clinical outcomes after percutaneous coronary intervention (PCI) with bare metal stenting versus coronary artery bypass grafting (CABG) are underpowered to properly assess safety end points like death, stroke, and myocardial infarction. Pooling

  1. 仿真三维虚拟支架技术在脑动脉狭窄介入治疗中的作用%Value of 3D virtual stenting in the interventional therapy of cerebral artery stenosis

    Institute of Scientific and Technical Information of China (English)

    罗杰; 杨振九; 王皓; 廖煜君; 吴剑煌; 张朋

    2015-01-01

    目的:探讨仿真三维虚拟支架技术在脑动脉狭窄介入治疗中的作用。方法选取脑动脉狭窄支架介入治疗患者34例,分为2组。三维数字减影脑血管造影(3D-DSA)组22例,其中男性13例,女性9例;年龄48~74岁,平均年龄62.5岁;通过3D-DSA重建方法,确定脑动脉狭窄的程度和部位,运用虚拟支架血管分析程序,得到脑动脉狭窄的虚拟支架数据参数,并指导血管内治疗。对照组12例,其中男性8例,女性4例;年龄52~76岁,平均年龄64.3岁;采用普通脑血管造影指导血管内治疗。结果与普通DSA相比,3D-DSA重建图像能够多角度清晰地观察和显示脑动脉狭窄的部位、形态、狭窄程度;以虚拟支架技术的数据参数为依据,选择相应型号的支架行介入治疗效果更满意。结论3D-DSA虚拟支架技术对脑动脉狭窄支架成形术有指导价值,便于施术者正确地选择合适的支架。%Objective To investigate the interventional treatment role of three-dimensional (3D) virtual stenting in cerebral artery stenosis. Methods A total of 34 cases of cerebral artery stenosis with interventional treatment were enrolled, which were divided into 2 groups, 3D digital subtraction angiography(3D-DSA) group and control group. In 3D-DSA group, which included 13 males and 9 females, aged 48-74 years old with mean age of 62.5 years old, the location and degree of stenosis were determined by 3D-DSA reconstruction. Virtual stent analysis technology was applied to obtain data parameters of virtual cerebral stent and guide the endovascular therapy. In control group, which included 8 males and 4 females, aged 52-76 years old with mean age of 64.3 years old, the common cerebrovascular angiography was used to guide endovascular treatment. Results Compared with control group, the site, shape and degree of stenosis in 3D-DSA group were clearly demonstrated in 3D reconstruction images

  2. Preliminary Evaluation of Clinical and Angiographic Outcomes with Biodegradable Polymer Coated Sirolimus-Eluting Stent in De Novo Coronary Artery Disease: Results of the MANIPAL-FLEX Study

    Directory of Open Access Journals (Sweden)

    Ranjan Shetty

    2016-01-01

    Full Text Available Objective. The objective of the MANIPAL-FLEX study was to evaluate the feasibility, preliminary safety, and efficacy of the Supraflex sirolimus-eluting stent (SES implantation, in de novo coronary artery disease, using clinical and quantitative coronary angiography (QCA follow-ups. Methods. This was a prospective, nonrandomized, multicenter, single-arm study that enrolled 189 patients with de novo coronary artery disease who were treated with the Supraflex SES. Of 189 patients enrolled, the first 61 consecutive patients who consented to a 9-month follow-up evaluation by QCA, irrespective of presence of symptoms, were to be followed up with angiography at 9 months. The primary endpoint of the study was target lesion failure (TLF, including cardiac death, myocardial infarction, and target lesion revascularization during 12-month follow-up after the index procedure. Results. The mean age of the study population was 58±11 years, with 51.3% (97/189 of hypertensive patients. Total of 66 lesions, analyzed by offline QCA, showed good scaffolding of the target vessel with in-stent late lumen loss at 9 months of 0.18±0.23 mm. The observed TLF at 30-day, 6-month, and 12-month follow-up were 2 (1.1%, 6 (3.2%, and 10 (5.3%, respectively. Conclusion. This study provides preliminary evidence for the feasibility, safety, and efficacy of the Supraflex sirolimus-eluting stent.

  3. Development of radiolabelled compound using reactor producted RI - Evaluation of Ho-166 endovascular therapy to prevent restenosis after PTCA or stenting for occlusive coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Hee; Choi, Byung Il; Kim, Han Soo [Ajou University, Suwon (Korea)

    2000-04-01

    Occlusive coronary artery disease is managed successfully by percutaneous transfemoral coronary angioplasty (PTCA) or stenting with 95% success rate. However, restenosis after PTCA is not uncommon and the reported incidence of reocclusion is about 30 {approx} 40%. Therefore, the objective of the research was to develop endovascular brachytherapy using liquid form of Ho-166 in order to inhibit neointimal hyperplasia responsible for restenosis following PTCA or stenting. Our research was carried out in 3 stages: First stage - The effectiveness of radiation was confirmed by using animal model. Following over-sized balloon injury to rat carotid artery and porcine coronary artery, various external radiation doses were delivered. Second stage - For radiation dose distribution within the coronary artery and its surrounding tissues, Gafchromic film was used. In vitro dose distribution of Ho-166 utilizing water phantom and Gafchromic film was measured. Third stage - None uniform dose distribution from Ho-166 within the balloon caused by small air bubbles was eliminated by negative suction method. More accurate dose distribution was also possible using newly developed micrometer by our physicist. Limited number of human trial was performed without adverse effect. 40 refs. (Author)

  4. Zotarolimus-eluting durable-polymer-coated stent versus a biolimus-eluting biodegradable-polymer-coated stent in unselected patients undergoing percutaneous coronary intervention (SORT OUT VI)

    DEFF Research Database (Denmark)

    Raungaard, Bent; Jensen, Lisette Okkels; Tilsted, Hans-Henrik

    2015-01-01

    BACKGROUND: New-generation drug-eluting coronary stents have reduced the risk of coronary events, especially in patients with complex disease or lesions. To what extent different stent platforms, polymers, and antiproliferative drugs affect outcomes, however, is unclear. We investigated the safety...... and efficacy of a third-generation stent by comparing a highly biocompatible durable-polymer-coated zotarolimus-eluting stent with a biodegradable-polymer-coated biolimus-eluting stent. METHODS: This open-label, randomised, multicentre, non-inferiority trial was done at three sites across western Denmark. All...... patients who presented with stable coronary artery disease or acute coronary syndromes and at least one coronary artery lesion (more than 50% stenosis) from March, 2011, to August, 2012, were assessed for eligibility. Patients were randomly assigned in a 1:1 ratio to receive either the durable-polymer...

  5. Impact of biodegradable versus durable polymer drug-eluting stents on clinical outcomes in patients with coronary artery disease: a meta-analysis of 15 randomized trials

    Institute of Scientific and Technical Information of China (English)

    Zhang Yaojun; Tian Nailiang; Dong Shengjie; Ye Fei; Li Minghui; Christos V.Bourantas; Javaid Iqbal

    2014-01-01

    Background Drug eluting stents (DESs) made with biodegradable polymer have been developed in an attempt to improve clinical outcomes.However,the impact of biodegradable polymers on clinical events and stent thrombosis (ST) remains controversial.Methods We searched Medline,the Cochrane Library and other internet sources,without language or date restrictions for articles comparing clinical outcomes between biodegradable polymer DES and durable polymer DES.Safety endpoints were ST (definite,definite/probable),mortality,and myocardial infarction (MI).Efficacy endpoints were major adverse cardiac event (MACE) and target lesion revascularization (TLR).Results We identified 15 randomized controlled trials (n=17 068) with a weighted mean follow-up of 20.6 months.There was no statistical difference in the incidence of definite/probable ST between durable polymer-and biodegradable polymerDES; relative risk (RR) 0.83; 95% confidence interval (CI) 0.62-1.11; P=0.22.Biodegradable polymer DES had similar rates of definite ST (RR 0.94,95% CI 0.66-1.33,P=0.72),mortality (RR 0.94,95% C/0.82-1.09,P=0.43),MI (RR 1.08,95% CI 0.92-1.26.P=0.35),MACE (RR 0.99,95% CI 0.91-1.09,P=0.85),and TLR (RR,0.94,95% CI 0.83-1.06,P=0.30) compared with durable polymer DES.Based on the stratified analysis of the included trials,the treatment effect on definite ST was different at different follow-up times:≤1 year favoring durable polymer DES and >1 year favoring biodegradable polymer DES.Conclusions Biodegradable polymer DES has similar safety and efficacy for treating patients with coronary artery disease compared with durable polymer DES.Further data with longer term follow-up are warranted to confirm the potential benefits of biodegradable polymer DES.

  6. In vitro comparison of self-expanding versus balloon-expandable stents in a human ex vivo model.

    Science.gov (United States)

    Grenacher, Lars; Rohde, Stefan; Gänger, Ellen; Deutsch, Jochen; Kauffmann, Günter W; Richter, Götz M

    2006-01-01

    The objective was to compare the radial strength and expansile precision of self-expanding stents and balloon-expandable stents in a human cadaver bifurcation model. Seven different self-expanding (LUMINEXX, JOSTENT SelfX, JOSTENT SelfX hrf, Sinus-Repo, Sinus SuperFlex, Easy Wallstent, SMART) and four different balloon-expandable stent models (Palmaz, Sinus Stent, SAXX Medium, JOSTENT peripheral), each type 10 stents (total n = 110 stents) were implanted into the common iliac arteries of human cadaver corpses. The maximum stent diameter was 10 mm for all models. After stent implantation, the specimens were filled with silicone caoutchouc. After 24 h, the vascular walls including the stents were removed from the hardened casts. Diameters were taken and the weight of the cast cylinders was measured in air and in purified water to calculate the volume of the bodies (according to Archimedes Law) as a relative but precise degree for the radial strength of the implanted stents. The cylindrical casts of the self-expanding stents showed lower mean diameters (8.2 +/- 1.0 mm) and mean volumes (0.60 +/- 0.14 ml/cm) than in the balloon-expandable stent group (10.1 +/- 0.3 mm and 0.71 +/- 0.04 ml/cm, respectively; p < 0.01). The nominal maximum diameter of 10 mm was not achieved in any of the self-expanding stents, but this was achieved in more than 70% (29/40) of the balloon-expandable stent specimens (p < 0.05). The variation between achieved volumes was significantly larger in self-expanding (range: 0.23-0.78 ml/cm) than in balloon-expandable stents (range: 0.66-0.81 ml/cm; p < 0.05). Self-expanding stents presented considerably lower radial expansion force and lower degree of precision than balloon-expandable stents.

  7. Age-based clinical and angiographic outcomes after sirolimus-eluting stent implantation in patients with coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    XU Bo; WU Yong-jian; YUAN Jin-qing; CHEN Jue; YOU Shi-jie; DAI Jun; XIA Ran; GAO Run-lin; LI Jian-jun; YANG Yue-jin; CHEN Ji-lin; QIAO Shu-bin; QIN Xue-wen; MA Wei-hua; YAO Min; LIU Hai-bo

    2007-01-01

    Background Advanced age independently predicts early and late mortality and major adverse cardiac events (MACE)after percutaneous coronary intervention (PCI). Randomized clinical trials indicate that sirolimus-eluting stent (SES)implantation reduces target lesion revascularization (TLR), but there are limited data on the impact of age on outcomes following SES implantation in patients with coronary artery disease (CAD) in real-world practice.Methods A total of 333 CAD patients with 453 lesions were enrolled in this study. Subjects were divided into two groups according to age. a young group (<65 years old, 244 patients with 369 lesions) and elderly group (≥65 years old, 89patients with 113 lesions). Clinical follow-up and quantitative coronary angiography (QCA) were performed seven months after PCI.Results Baseline clinical, demographic, angiographic, and procedural chararcteristics were similar in both groups,except that there were more female patients in the elderly group (21.3% vs 9.8%, P=0.006). Primary success rate was similar in both groups (96.5% in young group vs 95.7% in elderly group, P>0.05). During angiographic follow-up at 7months, binary in-stent restenosis and in-segment restenosis rates were not significantly different between the two groups (4.7% vs 1.8%; 9.7% vs 8.8%, P>0.05 respectively). Both sub-acute and late thrombosis rates were similar in the two groups (0.3% vs 0.9% and 1.2% vs 0.9%, P>0.05 respectively). TLR was not significantly different between the two groups (6.5% vs 3.5%; P=0.246). The rates of bleeding, stroke, angina rehospitalization during the follow-up period were also similar in both groups (P>0.05 respectively).Conclusion Despite a high-risk clinical profile, coronary SES implantation can be safely and effectively performed in elderly patients with a similar procedural success rate, a low complication rate, and excellent 7-month outcomes.

  8. Balloon-guided navigation technique to perform stenting in an acutely angled anterior cerebral artery.

    Science.gov (United States)

    Cohen, José E; Gomori, John M; Moscovici, Samuel; Itshayek, Eyal

    2012-03-01

    The complex anatomic features of wide-necked anterior communicating artery aneurysms represent an endovascular challenge. Compliant balloons and microstents are frequently required to achieve aneurysm occlusion. When the angle between the A1 and A2 segments is acute, microcatheter navigation is hazardous, and may be difficult or sometimes impossible with standard techniques. We present our technique using a support balloon to facilitate guidewire engagement and navigation of A2, and to assist with microcatheterization in this unfavorable vascular anatomy.

  9. Implante de stents farmacológicos na artéria descendente anterior: indicadores de eventos tardios Implante de Stents farmacológicos en la arteria descendente anterior: indicadores de eventos tardíos Pharmacological stent deployment in the left anterior descending artery: late event indicators

    Directory of Open Access Journals (Sweden)

    Marcelo de Freitas Santos

    2009-01-01

    ógicos en las lesiones ateroscleróticas de la arteria descendente anterior e identificar, entre las características clínicas, angiográficas y de ultrasonido intravascular, cuales son las que permiten predecir riesgos de eventos cardiacos MÉTODOS: De mayo de 2002 a agosto de 2005, se trataron a 205 pacientes con implante de 236 stents farmacológicos guiados por ultrasonido intravascular. RESULTADOS: Con un seguimiento promedio de 711 días, la tasa de trombosis del stent fue del 0,48%, la misma que se observó para infarto agudo de miocardio o cirugía de revascularización. La tasa de revascularización de la lesión tratada fue del 7,31% y la tasa global de eventos fue del 10,24%. Los indicadores de eventos, conforme análisis multivariada, fueron el implante de más de un stent en la misma arteria, lesiones concéntricas y área mínima intrastent medida por el ultrasonido intravascular menor que 3,88 mm². CONCLUSIÓN: Tomando como base los datos obtenidos con esta investigación, concluimos que la revascularización de la arteria descendente anterior con implante de stents farmacológicos, elegidos y optimizados por el ultrasonido intravascular, presenta un bajo índice de eventos tardíos. El implante de dos stents farmacológicos para el tratamiento de las lesiones largas fue el principal factor independiente para la ocurrencia de eventos tardíos. El área luminal final mayor que 3,88 mm², obtenida en los segmentos de pequeños diámetros de referencia es un indicador independiente de evolución libre de eventos.BACKGROUND: The efficacy of pharmacological stents in decreasing the incidence of cardiac events is not homogeneous for all lesions or patient subgroups. OBJECTIVE: 1 To evaluate the late clinical evolution of patients submitted to pharmacological stent implantation in atherosclerotic lesions of the left anterior descending artery; 2 to identify, among the clinical, angiographic and intravascular ultrasonographic characteristics, the ones predictive of

  10. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner® catheter to deliver stents for anomalous right coronary artery

    Directory of Open Access Journals (Sweden)

    Toshiki Kuno

    2015-10-01

    Full Text Available Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  11. Airport and superficial femoral artery obstruction due to a wandering coronary stent: the possibility of airport detection of modern implant metals.

    Science.gov (United States)

    Teijink, J A W; van Herwaarden, J A; van den Berg, J C; Overtoom, T C; Moll, F L

    2004-06-01

    In the treatment of coronary artery disease, peripheral loss of a coronary stent is an unusual complication. We present the case of a patient who suggested that his right leg claudication was caused by a slipped coronary stent 2 years previously. The patient was convinced about this unusual finding based on an airport security check. Examination proved him to be right. However, the ability to detect an object using eddy currents is dependent on the object's permeability and its conductivity. Ferrous (iron) content is not the critical factor. Modern implant materials and processing techniques result in implants that are difficult to magnetize i.e. their permeability is very low. In addition their conductivity is very low. This enables modern implants to escape detection at airports. For this reason the event at the airport, as described by our patient, is considered coincidental.

  12. Newest-generation drug-eluting and bare-metal stents combined with prasugrel-based antiplatelet therapy in large coronary arteries

    DEFF Research Database (Denmark)

    Jeger, Raban; Pfisterer, Matthias; Alber, Hannes

    2012-01-01

    In the BAsel Stent Kosten Effektivitäts Trial PROspective Validation Examination (BASKET-PROVE), drug-eluting stents (DESs) had similar 2-year rates of death and myocardial infarction but lower rates of target vessel revascularization and major adverse cardiac events compared with bare-metal sten...... (BMSs). However, comparative clinical effects of newest-generation DES with biodegradable polymers vs second-generation DES or newest-generation BMS with biocompatible coatings, all combined with a prasugrel-based antiplatelet therapy, on 2-year outcomes are not known....

  13. The Pharmacokinetics of Biolimus A9 after Elution from the Nobori Stent in Patients with Coronary Artery Disease: The NOBORI PK Study

    Science.gov (United States)

    Ostojic, Miodrag; Sagic, Dragan; Jung, Robert; Zhang, Yan-Ling; Nedeljkovic, Milan; Mangovski, Ljupco; Stojkovic, Sinisa; Debeljacki, Dragan; Colic, Mirko; Beleslin, Branko; Milosavljevic, Bratislav; Orlic, Dejan; Topic, Dragan; Karanovic, Nevena; Paunovic, Dragica; Christians, Uwe

    2008-01-01

    Objectives The aim of this study was to assess the pharmacokinetics and tolerability of Biolimus A9 eluted from Nobori coronary stents. Background The release kinetics and pharmacokinetics of drugs delivered via coronary stents have been shown to play an essential role in the efficacy and safety of drug eluting stents. Methods 20 patients with coronary artery disease were treated with single 14 mm (10 patients) or 28 mm long stent (10 patients). Blood samples were drawn at 16 time points to determine the pharmacokinetics of Biolimus A9. At seven time points, complete laboratory and toxicology panels were assessed to screen for potential Biolimus A9 toxicity. The primary endpoint of the study was the systemic blood concentrations of Biolimus A9 after 28 days and 6 months as measured using highly specific and sensitive liquid chromatography- tandem mass spectrometry assay. Results At 28 days, 6 patients (30%) had quantifiable Biolimus A9 concentrations in blood. The highest Biolimus A9 blood concentration measured in any sample was 32.2 pg/mL. The median time to maximum concentration was 2 hours, ranging from 0.05 hours to 3 months. Six months after stent implantation, only 1 of 20 patients had measurable Biolimus A9 concentrations at the lowest level of quantification, while at 9 months no sample had quantifiable Biolimus A9 concentrations. Laboratory and toxicology assessments did not indicate any impact of Biolimus A9 on the evaluated parameters. Conclusion Results of this study suggest that systemic exposure to Biolimus A9 was very low and that Biolimus A9 was well tolerated. PMID:19016466

  14. Preliminary findings of recanalization and stenting for symptomatic vertebrobasilar artery occlusion lasting more than 24 h: A retrospective analysis of 21 cases

    Energy Technology Data Exchange (ETDEWEB)

    He, Yingkun, E-mail: heyingkun@126.com [Cerebrovascular Center, Henan Provincial People' s Hospital, Zhengzhou University, Zhengzhou (China); Wang, Ziliang [Cerebrovascular Center, Henan Provincial People' s Hospital, Zhengzhou University, Zhengzhou (China); Li, Tianxiao, E-mail: dr.litianxiao@vip.163.com [Cerebrovascular Center, Henan Provincial People' s Hospital, Zhengzhou University, Zhengzhou (China); Jiang, Wei-Jian [Stroke Center, People' s Liberation Army Second Artillery Corps General Hospital, Beijing (China); Zhu, Liangfu; Xue, Jiangyu; Bai, Weixing [Cerebrovascular Center, Henan Provincial People' s Hospital, Zhengzhou University, Zhengzhou (China); Hui, Ferdinand [Cerebrovascular Center, Cleveland Clinic Foundation, Cleveland, OH (United States)

    2013-09-15

    Purpose: To evaluate the technical feasibility, safety and short-term treatment effects of recanalization and stenting for intracranial symptomatic vertebrobasilar artery occlusion (VBAO) lasting more than 24 h. Methods and materials: Twenty-one consecutive patients with VBAO refractory to aggressive medical treatment were enrolled into this study and underwent recanalization and stenting. The rate of recanalization was evaluated radiographically and the functional outcome was examined using modified Rankin Scale (mRS) scores. Results: Median time between imaging-documented occlusion and endovascular recanalization was 10.5 days (IR, Interquartile Range: 6.5–18); technique success ratio of recanalization was 95.2%. There were 3 periprocedural complications. Median mRS score was 4 (IR, 2.5–5) prior to procedure and 4 (IR, 1–5) at discharge (P < 0.05). One stroke and one death occurred within 30 days after recanalization. Mean duration of clinical follow-up was 15.5 months. One transient ischemic attack, one stroke and one death occurred beyond 30-day window. Mean angiographic follow-up was 10.6 months in 10 patients. Four patients developed in-stent restenosis or occlusion, and two of them were symptomatic. Subgroup analyses revealed better functional recovery (lower mRS) in patients with vertebral artery occlusion (VAO) (P < 0.05). Conclusions: Endovascular recanalization and stenting for symptomatic VBAO lasting more than 24 h were technically feasible and patients with VAO benefited from the treatment with significant functional recovery. However, the complexity of the procedure and high risk of complication should prompt extreme caution.

  15. Comparison of the sirolimus-eluting versus paclitaxel-eluting coronary stent in patients with diabetes mellitus: the diabetes and drug-eluting stent (DiabeDES) randomized angiography trial

    DEFF Research Database (Denmark)

    Maeng, Michael; Jensen, Lisette Okkels; Galloe, Anders Michael;

    2008-01-01

    The aim of the present study was to evaluate angiographic late luminal loss after the implantation of sirolimus-eluting Cypher stents and paclitaxel-eluting Taxus stents in patients with diabetes. The study was a Danish multicenter, open-label, randomized trial. One hundred fifty-three patients...... with diabetes with coronary artery disease were randomized to Cypher (n = 76) or Taxus (n = 77) stent implantation. All patients were followed for 8 months. The primary end point was 8-month angiographic in-stent late luminal loss. This primary end point was reduced in the Cypher group compared with the Taxus.......8%) in the Cypher and Taxus groups, respectively (p = 0.25). Definite stent thrombosis was observed in 2 patients (in the Taxus group), no patients had probable stent thrombosis, and 1 patient in each group had possible stent thrombosis. Major adverse cardiac events (cardiac death, myocardial infarction, definite...

  16. 血管内支架治疗椎动脉梭形动脉瘤%Endovascular treatment of fusiform aneurysms of vertebral artery using stents

    Institute of Scientific and Technical Information of China (English)

    孟凡国; 于建军; 费昶

    2009-01-01

    目的 探讨血管内支架治疗颅内椎动脉梭形动脉瘤的临床效果.方法 回顾血管内支架治疗的23例椎动脉瘤患者(12例破裂,11例未破裂).临床结果进行GOS评分.结果 23例发现24个椎动脉梭形动脉瘤,共放置了25个支架.所有支架均成功释放,19例用弹簧圈栓塞动脉瘤,3例只放置了支架,1例放置了2枚Neuroform支架来覆盖瘤颈.没有发生与操作技术相关的并发症.临床随访22例(96%)恢复良好(GOS=5),1例(4%)由于术中动脉瘤破裂出血而死亡(GOS=1).结论 血管内应用支架是治疗累及小脑后下动脉上、对侧椎动脉发育不好或未破裂的椎动脉梭形动脉瘤的一种有效的治疗方法.%Objective To report clinical outcomes of endovascular treatment of fusiform aneurysms of vertebral artery (VA) using stents. Methods Consecutive 23 cases (12 ruptured, 11 unruptured) of vertebral artery fusiform aneurysms treated with stents were retrospectively reviewed. Their clinical outcomes were graded with Glasgow outcome scale. Results Twenty-five stents were placed in 23 patients for 24 fusiform VA aneurysms. All patients were successfully treated using stents. In 19 patients coil-embolization of the aneurysmal lumen was used. One aneurysm was treated by placement of 2 stents covering the dissection site. There was no technique-related complication. According to the Glasgow Outcome Scale (GOS), 22 patients (96 %) had a good recovery and 1 (4 %) died due to intraoperative rebleeding. Conclusion Endovascular therapy using stents may be a useful treatment in patients with fusiform VA aneurysms involving the PICA or hypoplasia of the eontralateral VA or unruptured VA aneurysms.

  17. Everolimus-eluting coronary stents

    Directory of Open Access Journals (Sweden)

    Alejandro Saez

    2010-09-01

    Full Text Available Alejandro Saez, Raul MorenoDivision of Interventional Cardiology, University Hospital La Paz, Madrid, SpainAbstract: Bare metal stents enabled a reduction in the risk of early procedural complications and restenosis in comparison with balloon angioplasty alone, but introduced a new and device-specific iatrogenic condition, ie, in-stent restenosis due to increased neointimal hyperplasia. Sirolimus- and paclitaxel-eluting stents reduce restenosis and the need for new revascularizations in comparison with bare metal stents, although at the cost of a slight increase in the risk of late stent thrombosis and a need for prolonged dual antiplatelet therapy. Everolimus is an analog of sirolimus with an increased solubility. In this review, the currently available evidence for everolimus-eluting stents is revised, including randomized trials against bare metal stents, and head-to-head trials comparing this stent with other drug-eluting stents.Keywords: coronary stents, restenosis, everolimus, review

  18. CT virtual endoscopy and 3D stereoscopic visualisation in the evaluation of coronary stenting.

    Science.gov (United States)

    Sun, Z; Lawrence-Brown

    2009-10-01

    The aim of this case report is to present the additional value provided by CT virtual endoscopy and 3D stereoscopic visualisation when compared with 2D visualisations in the assessment of coronary stenting. A 64-year old patient was treated with left coronary stenting 8 years ago and recently followed up with multidetector row CT angiography. An in-stent restenosis of the left coronary artery was suspected based on 2D axial and multiplanar reformatted images. 3D virtual endoscopy was generated to demonstrate the smooth intraluminal surface of coronary artery wall, and there was no evidence of restenosis or intraluminal irregularity. Virtual fly-through of the coronary artery was produced to examine the entire length of the coronary artery with the aim of demonstrating the intraluminal changes following placement of the coronary stent. In addition, stereoscopic views were generated to show the relationship between coronary artery branches and the coronary stent. In comparison with traditional 2D visualisations, virtual endoscopy was useful for assessment of the intraluminal appearance of the coronary artery wall following coronary stent implantation, while stereoscopic visualisation improved observers' understanding of the complex cardiac structures. Thus, both methods could be used as a complementary tool in cardiac imaging.

  19. LOW-DOSE RADIOACTIVE ENDOVASCULAR STENTS PREVENT NEOINTIMAL HYPERPLASIA IN RABBITS RESTENOSIS MODEL

    Institute of Scientific and Technical Information of China (English)

    任晓庆; 黄定九; 黄刚; 毛家亮

    2002-01-01

    Objective To evaluate the effects of low-dose radioactive stents on the prevention of restenosis in rabbit model. Methods The stents were bombarded with suitable charged particles of adapted energy in the cyclotron to create a proper mixture of the radionuclides 59Fe, 60Co, 58Co, 51Cr, and 54Mn. The radioactive stents were implanted in the iliac arteries of rabbits. The effects of radioactive stents on prevention of restenosis were assessed by angiography, histomorphometry and immunocytochemistry. Results All the iliac arteries that had been implanted with radioactive stents were patent on angiography and had no radiation complication during the 1~2 months of follow-up. There was a significant reduction in neointimal area (0.37±0.14mm2 vs. 0.81±0.10mm2, P<0.01), percent area stenosis (6.7±2.9% vs. 13.2±1.4%, P<0.01) and PCNA immunoreactive rate (2.00±1.58% vs. 10.88±6.98%, P<0.05) in the radioactive stent group compared with the control stent group. Conclusion Radioactive stents with an active of 0.91~1.65 μCi could inhibit SMC proliferation and neointimal hyperplasia in animal restenosis model. The low-dose radioactive stents are safe and feasible for prevention of restenosis.

  20. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events

    DEFF Research Database (Denmark)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph

    2014-01-01

    coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. CONCLUSIONS: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium......OBJECTIVES: To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. DESIGN: Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were...... used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. DATA SOURCES AND STUDY SELECTION: Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus...

  1. Stent-assisted angioplasty for atherosclerotic stenosis of the carotid artery. An overview; Stentgeschuetzte Angioplastie der arteriosklerotischen Stenose der A. carotis interna. Ein Ueberblick

    Energy Technology Data Exchange (ETDEWEB)

    Boeckh-Behrens, T.; Brueckmann, H. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Abteilung fuer Neuroradiologie, Muenchen (Germany)

    2008-11-15

    For symptomatic stenosis of the carotid artery the invasive options for treatment (by means of stent or operation) are superior to conservative medical treatment. Recent multi-center randomized controlled trials, which will be presented here, indicate that stenting in the treatment of symptomatic carotid stenosis is neither safer nor more effective than carotid endarterectomy. When carried out by an experienced interventionalist stent-assisted angioplasty (CAS) is an alternative to carotid endarterectomy. Subgroup-analysis indicates that for patients older than 70 years of age invasive techniques should be the method of choice. In the case of contralateral high-grade stenosis or occlusion, CAS is the method of choice. For patients treated by stenting, the periprocedural complication rate is not influenced by the use of protection systems. The present results on symptomatic carotid stenosis should not be transferred to the therapy of asymptomatic carotid stenosis. A 3-armed study (SPACE2) on the comparison of the best medical treatment with the invasive treatment modalities (CAS or CEA) is in preparation and will be started in 2 months. (orig.) [German] Bei symptomatischen arteriosklerotischen Stenosen der A. carotis sind die invasiven Behandlungen (mittels Stent oder Operation) der medikamentoesen konservativen Therapie ueberlegen. Multizentrische randomisierte kontrollierte Studien der letzten Jahre, die hier vorgestellt werden, haben gezeigt, dass die endovaskulaere Therapie zur Behandlung symptomatischer Karotisstenosen weder sicherer noch effektiver ist als die operative Therapie. In der Hand eines erfahrenen Interventionalisten ist die stentgeschuetzte Angioplastie (CAS) eine ebenbuertige Behandlungsalternative zur Karotisendarterektomie. Subgruppenanalysen weisen darauf hin, dass Patienten, die aelter als 70 Jahre sind, primaer operiert werden sollten. Bei gleichzeitig bestehender kontralateraler hochgradiger Stenose oder Verschluss ist die CAS Methode der

  2. Impact of Vertebral Artery Stent Implantation on Hemodynamics of Patients With Intracranial Vertebral Artery Stenosis and the Influencing Factors of Postoperative Restenosis%椎动脉支架置入术对颅内椎动脉狭窄患者血流动力学的影响及术后再狭窄的影响因素研究

    Institute of Scientific and Technical Information of China (English)

    王铁军; 石富铭; 陈书阁; 王金梅

    2016-01-01

    Objective to investigate the impact of vertebral artery stent implantation on hemodynamics of patients with intracranial vertebral artery stenosis,to analyze the influencing factors of postoperative restenosis. Methods From February 2012 to February 2014,a total of 106 patients with intracranial vertebral artery stenosis were selected in the Department of Neurology,People′s Hospital of Daxing District,Beijing,all of them received vertebral artery stent implantation and were followed up for 1 year(average). Pulsatility index(PI),peak systolic velocity(PSV)and end diastolic velocity(EDV)of intracranial vertebral artery,arterial diameter,resistance index( RI),PSV and EDV of extracranial vertebral artery were observed before surgery,after 1 week,3 moths,6 months and 12 months of surgery. According to the follow - up result,the 106 patients were divided into A group( occurred postoperative restenosis,n = 38) and B group( did not occurred postoperative restenosis,n = 68),gender,age,smoking status and underlying disease were compared between the two groups,and the influencing factors of postoperative restenosis were analyzed. Results After 1 week,3 moths,6 months and 12 months of surgery,PI of intracranial vertebral artery was statistically significantly higher than before surgery,respectively,while PSV and EDV of intracranial vertebral artery were statistically significantly slower than those before surgery(P 0. 05),while incidence of coronary heart disease and diabetes mellitus of A group was statistically significantly higher than that of B group, respectively( P 0.05);再狭窄组患者冠心病发生率及糖尿病发生率高于无再狭窄组(P <0.05)。结论椎动脉支架置入术能有效改善 IVAS 患者椎动脉颅内段及颅外段血流动力学,增加颅内血流灌注,而 IVAS 患者术后再狭窄可能与基础疾病有关,与性别、年龄及吸烟无关。

  3. Experiment Study of The Preventive Effects of Valsartan Eluting Stent on In- stent Restenosis

    Institute of Scientific and Technical Information of China (English)

    陈津; 陈纪言; 周颖玲; 李光; 罗建方; 余丹青; 张励庭; 黄文晖

    2003-01-01

    Objectives Background -Neointima hyperplasia and arterial re modeling are themain mechanisms of restenosis after percutaneoustransluminal coronary angioplasty. The successful useof coronary stents neutralizes the ac ute elastic recoiland improves the remodeling mode with reducingrestenosis rate by 10 % . But the in - stent neointimahyperplasia becomes more severe. This study aims toset up model of in - stent restenosis in vivo, and to e-valuate the preventive role of implantation of valsartaneluting stent for restenosis. Methods and ResultsTwenty -two male New Zealand white rabbits were di-vided into control group and valsartan group. In-travascular ultrasonic (IVUS) results showed the in-trastent neointimal areas of the control group werelarger than those of the valsartan group ( P < 0.01 ) .The minimal lumen area of control group was smallerthan that of the valsartan group ( P < 0.01). Angiog-raphy results showed the normal lumen diameters weresimilar between two groups ( P> 0.05) . The lumenstenosis rates compared with the normal diameters ofthe valsartan group were significantly improved overthat of the control group ( P < 0. 05) . It was compa-rable to the IVUS analysis. There were no cases of a-neurysm or thrombosis. Conclusions Valsartan e-luting stents produced a significant inhibition ofneointimal hyperplasia and luminal encroachment inrabbits without obviously producing any serious side -effects. These results demonstrate the potential thera-peutic benefit of valsartan eluting stents in the pre-vention and treatment of human coronary restenosis.

  4. Percutaneous transluminal angioplasty and stenting for severe stenosis of the intracranial extradural internal carotid artery causing transient ischemic attack or minor stroke.

    Science.gov (United States)

    Ko, Jun Kyeung; Choi, Chang Hwa; Cha, Seung Heon; Choi, Byung Kwan; Cho, Won Ho; Kang, Tae Ho; Sung, Sang Min; Cho, Han Jin; Lee, Tae Hong

    2015-08-01

    The purpose of this study is to assess the technical feasibility and clinical efficacy of percutaneous transluminal angioplasty and stenting (PTAS) for symptomatic stenosis of the intracranial extradural (petrous and cavernous) internal carotid artery (ICA).Review of medical records identified 26 consecutive patients who underwent PTAS using a balloon-expandable coronary stent (n = 15, 57.7%) or a Wingspan self-expandable stent (n = 11, 42.3%) for treatment of severe stenosis (>70%) involving the intracranial extradural ICA. The inclusion criteria were transient ischemic attack with an ABCD(2) score of ≥3 (n = 12, 46.2%) or minor stroke with an NIHSS score of ≤4 (n = 14, 53.8%). Technical success rates, complications, and angiographic and clinical outcomes were analyzed retrospectively.PTAS was technically successful in all patients. The mean stenosis ratio decreased from 77.1% to 10.0% immediately after PTAS. The overall incidence of procedural complications was 23.1%, and the postoperative permanent morbidity/mortality rate was 7.7%. A total of 22 patients were tracked over an average period of 29.9 months. During the observation period, 20 patients (90.9%) had no further cerebrovascular events and stroke recurrence occurred in two patients (9.1%), resulting in an annual stroke risk of 3.7%. Two cases (11.1%) of significant in-stent restenosis (>50%) were found on follow-up angiography (n = 18).PTAS for severe stenosis (>70%) involving the intracranial extradural ICA showed a good technical feasibility and favorable clinical outcome in patients with transient ischemic attack or minor stroke.

  5. Value of endovascular stenting for symptomatic intracranial artery stenosis%症状性颅内动脉粥样硬化性狭窄血管内支架成形术的价值

    Institute of Scientific and Technical Information of China (English)

    蒋保华; 李兴; 周石; 宋杰; 蒋天鹏; 王黎洲

    2015-01-01

    目的:评价颅内动脉狭窄支架成形术(ICASS)治疗症状性颅内动脉狭窄的疗效、安全性和中期效果。方法观察21例症状性颅内动脉狭窄患者 ICASS 术后的手术成功率、狭窄改善率及并发症发生率;比较分析术前、术后(1、3、6、12个月及2年) NIHSS 和 MRS 量表评分的变化及随访期间缺血性脑血管事件的发生情况。结果1例因术中脑出血,手术被迫中止,20例手术成功,手术技术成功率95.2%,血管平均狭窄率从治疗前(73.4±7.9)%降为治疗后(13.7±9.2)%,围手术期并发症发生率为4.8%。9例术后6个月接受 DSA 检查,血管平均狭窄率为(29.5±12.2)%,未发现再狭窄病例;术后3、6、12个月及2年 NIHSS 评分、MRS 评分均较术前显著改善(均 P 1个月、有2个以上独立危险因素、未系统进行基础疾病治疗的患者,术后易再发脑血管事件(均 P<0.05)。结论ICASS 治疗症状性颅内动脉狭窄相对安全有效,中期疗效满意,需注意围手术期可能发生严重并发症。%Objective To evaluate the curative effect,safety,and medium-term effect of intracranial artery stenosis stent (ICASS) for the treatment of the symptomatic intracranial artery stenosis.Methods ICASS was performed in 21 cases with the symptomatic intracranial artery stenosis.The stenting success rate,the improvement rate of stenosis post-stenting and the incidence of complications were observed.The change of the scores of the Modified Rankin Scale (MRS)and National Institutes of Health Stroke Scale (NIHSS)between pre-and post-stenting (1 month,3 months,6 months,12 months and 2 years)and the occurrence of ischemic cerebrovascular events after stenting were compared and analyzed respectively.Results Except one case failed because of intracranial hemorrhage during the operation,other 20 patients were treated with endovascular stent plasty successfully,the total technical achievement ratio was 95.2%.The aver-age stenosis ratio

  6. Biocompatibility of Coronary Stents

    Directory of Open Access Journals (Sweden)

    Thamarasee M. Jeewandara

    2014-01-01

    Full Text Available Cardiovascular disease is the dominant cause of mortality in developed countries, with coronary artery disease (CAD a predominant contributor. The development of stents to treat CAD was a significant innovation, facilitating effective percutaneous coronary revascularization. Coronary stents have evolved from bare metal compositions, to incorporate advances in pharmacological therapy in what are now known as drug eluting stents (DES. Deployment of a stent overcomes some limitations of balloon angioplasty alone, but provides an acute stimulus for thrombus formation and promotes neointimal hyperplasia. First generation DES effectively reduced in-stent restenosis, but profoundly delay healing and are susceptible to late stent thrombosis, leading to significant clinical complications in the long term. This review characterizes the development of coronary stents, detailing the incremental improvements, which aim to attenuate the major clinical complications of thrombosis and restenosis. Despite these enhancements, coronary stents remain fundamentally incompatible with the vasculature, an issue which has largely gone unaddressed. We highlight the latest modifications and research directions that promise to more holistically design coronary implants that are truly biocompatible.

  7. A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program

    Directory of Open Access Journals (Sweden)

    Wehrenberg Scott

    2010-01-01

    Full Text Available Abstract Background Paclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation paclitaxel-eluting stent which incorporates a novel, thinner-strut, platinum-enriched metal alloy platform. The stent is intended to have enhanced radiopacity and improved deliverability compared to other paclitaxel-eluting stents. The safety and efficacy of the TAXUS Element stent are being evaluated in the pivotal PERSEUS clinical trials. Methods/Design The PERSEUS trials include two parallel studies of the TAXUS Element stent in single, de novo coronary atherosclerotic lesions. The PERSEUS Workhorse study is a prospective, randomized (3:1, single-blind, non-inferiority trial in subjects with lesion length ≤28 mm and vessel diameter ≥2.75 mm to ≤4.0 mm which compares TAXUS Element to the TAXUS Express2 paclitaxel-eluting stent system. The Workhorse study employs a novel Bayesian statistical approach that uses prior information to limit the number of study subjects exposed to the investigational device and thus provide a safer and more efficient analysis of the TAXUS Element stent. PERSEUS Small Vessel is a prospective, single-arm, superiority trial in subjects with lesion length ≤20 mm and vessel diameter ≥2.25 mm to Discussion The TAXUS PERSEUS clinical trial program uses a novel statistical approach to evaluate whether design and metal alloy iterations in the TAXUS Element stent platform provide comparable safety and improved procedural performance compared to the previous generation Express stent. PERSEUS trial enrollment is complete and primary endpoint data are expected in 2010. PERSEUS Workhorse and Small Vessel are registered at http://www.clinicaltrials.gov, identification numbers NCT00484315 and NCT00489541.

  8. 320-Multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting: Technical note

    Energy Technology Data Exchange (ETDEWEB)

    San Millan Ruiz, Diego, E-mail: dsanmil1@jhmi.ed [Division of Interventional Neuroradiology, Department of Radiology, Johns Hopkins Hospital, 600 North Wolfe Street, B-100, Baltimore, MD 21287 (United States); Murphy, Kieran, E-mail: KMURPHY@jhmi.ed [Division of Interventional Neuroradiology, Department of Radiology, The Johns Hopkins Hospital, 600 North Wolfe Street, B-100, Baltimore, MD 21287 (United States); Gailloud, Philippe, E-mail: pgailloud@cerebrovascular.ne [Division of Interventional Neuroradiology, Department of Radiology, Johns Hopkins Hospital, 600 North Wolfe Street, B-100, Baltimore, MD 21287 (United States)

    2010-06-15

    Introduction: Multidetector CT (MDCT) is increasingly used for the investigation of neurovascular disorders, but restricted z-axis coverage (3.2 cm for 64-MDCT) currently limits perfusion to a small portion of the brain close to the circle of Willis, and precludes dynamic angiographic appreciation of the entire brain circulation. We illustrate the clinical potential of recently developed 320-MDCT extending the z-axis coverage to 16 cm in a patient with symptomatic carotid artery stenosis. Methods: In a 74-year-old patient presenting with critical symptomatic stenosis of the left CCA, pre- and post-carotid artery stenting whole-head subtracted dynamic MDCT angiography and perfusion were obtained in addition to CT angiography of the supra-aortic trunks. Both whole-head subtracted MDCT angiography and perfusion demonstrated delayed left ICA circulation, which normalized after carotid stenting. Discussion: 320-MDCT offers unprecedented z-axis coverage allowing for whole-brain perfusion and subtracted dynamic angiography of the entire intracranial circulation. These innovations can consolidate the role of MDCT as a first intention imaging technique for cerebrovascular disorders, in particular for the acute management of stroke.

  9. The clinical effect obervation of Apollo stent in the treatment of vertebral artery stenosis%Apollo支架治疗椎动脉狭窄的疗效观察

    Institute of Scientific and Technical Information of China (English)

    张睿; 陈灿中; 王灿明

    2016-01-01

    目的:观察 Apollo支架治疗椎动脉狭窄的疗效。方法选择椎动脉狭窄患者50例,均采用 Apollo支架治疗,比较治疗前后椎动脉平均狭窄率、美国国立卫生研究院卒中量表(NIHSS)评分、改良 Rankin量表(mRS)评分以及临床症状改善情况。结果治疗后患者的椎动脉平均狭窄率、NIHSS评分、MRS评分均低于治疗前,差异均有统计学意义(P <0.05);治疗后患者的临床症状明显改善,差异有统计学意义(P <0.05)。结论 Apollo支架治疗椎动脉狭窄具有明显的临床疗效,患者的临床症状得到改善,值得在临床上进一步推广应用。%Objective To observe the efficacy of Apollo stent in the treatment of patients with vertebral artery steno-sis. Methods 50 patients with vertebral artery stenosis who treated with Apollo stent were selected to be observed. The aver-age stenosis rate,NIHSS score,mRS score and clinical symptoms of patients were compared between before and after treatment. Results After treatment,the average stenosis rate,NIHSS score and mRS score were all lower than those before treatment,the differences were statistically significant(P < 0. 05). The clinical symptoms were significantly improved after treatment(P <0. 05). Conclusion Apollo stent in the treatment of vertebral artery stenosis has obvious clinical curative effect,and the clini-cal symptoms of patients are significantly improved,which is worth to further promote the application in clinical practice.

  10. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rose Mary Ferreira Lisboa da, E-mail: roselisboa@cardiol.br [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Silva, Carlos Augusto Bueno [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Greco, Otaviano José [Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Moreira, Maria da Consolação Vieira [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil)

    2014-08-15

    The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  11. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Directory of Open Access Journals (Sweden)

    Rose Mary Ferreira Lisboa da Silva

    2014-08-01

    Full Text Available Background: The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. Objective: To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. Methods: This study assessed 61 patients (mean age, 64.0 years; 35 men with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform, measuring the low-frequency (LF and high-frequency (HF components, and the LF/HF ratio before and during the procedure. Results: Bare-metal stent was implanted in 34 patients, while the others received drug-eluting