WorldWideScience

Sample records for artery blood flow

  1. Modeling of blood flow in arterial trees.

    Science.gov (United States)

    Anor, Tomer; Grinberg, Leopold; Baek, Hyoungsu; Madsen, Joseph R; Jayaraman, Mahesh V; Karniadakis, George E

    2010-01-01

    Advances in computational methods and medical imaging techniques have enabled accurate simulations of subject-specific blood flows at the level of individual blood cell and in complex arterial networks. While in the past, we were limited to simulations with one arterial bifurcation, the current state-of-the-art is simulations of arterial networks consisting of hundreds of arteries. In this paper, we review the advances in methods for vascular flow simulations in large arterial trees. We discuss alternative approaches and validity of various assumptions often made to simplify the modeling. To highlight the similarities and discrepancies of data computed with different models, computationally intensive three-dimensional (3D) and inexpensive one-dimensional (1D) flow simulations in very large arterial networks are employed. Finally, we discuss the possibilities, challenges, and limitations of the computational methods for predicting outcomes of therapeutic interventions for individual patients. PMID:20836052

  2. Venous flow velocity, venous volume and arterial blood flow

    International Nuclear Information System (INIS)

    The relationship of arterial blood flow and venous volume to venous flow velocity was studied in normal subjects. The effects of current modes of treatment in venous thrombosis and of a vasodilator drug on venous flow velocity were also investigated. Total calf flow and venous volume were measured by venous occlusion plethysmography while venous flow axial velocity was determined by the transit time of 131I albumin from calf to inguinal region. Local intravenous epinephrine administration induced venoconstriction and increased venous flow velocity. Intra-arterial isoproterenol and angiotensin increased and decreased arterial flow, respectively, with no change in venous flow velocity or volume, but local heat increased arterial flow and venous flow velocity with no change in venous volume. Local cold, despite venoconstriction, decreased venous flow velocity accompanied by decreased arterial flow. Intravenous heparin did not affect venous flow velocity. Intravenous but not oral nylidrin increased venous flow velocity. Therefore venous flow velocity can be significantly increased by venoconstriction, by large increases in arterial flow (local heat), and by a parenteral vasodilator drug. These experiments indicate that there is a basis for applying heat but not cold in the prevention and treatment of venous thrombosis

  3. Arterial secondary blood flow patterns visualized with vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Hansen, Jens Munk;

    2011-01-01

    This study presents the first quantification and visualisation of secondary flow patterns with vector flow ultrasound. The first commercial implementation of the vector flow method Transverse Oscillation was used to obtain in-vivo, 2D vector fields in real-time. The hypothesis of this study...... was that the rotational direction is constant within each artery. Three data sets of 10 seconds were obtained from three main arteries in healthy volunteers. For each data set the rotational flow patterns were identified during the diastole. Each data set contains a 2D vector field over time and with the vector angles...... and velocity magnitudes the blood flow patterns were visualised with streamlines in Matlab (Mathworks, Natick, MA, USA). The rotational flow was quantified by the angular frequency for each cardiac cycle, and the mean rotational frequencies and standard deviations were calculated for the abdominal aorta f-1...

  4. PERFORMANCE MODELING AND ANALYSIS OF BLOOD FLOW IN ELASTIC ARTERIES

    Institute of Scientific and Technical Information of China (English)

    Anil Kumar; C.L. Varshney; G.C. Sharma

    2005-01-01

    Two different non-Newtonian models for blood flow are considered, first a simple power law model displaying shear thinning viscosity, and second a generalized Maxwell model displaying both shear thinning viscosity and oscillating flow viscous-elasticity. These models are used along with a Newtonian model to study sinusoidal flow of blood in rigid and elastic straight arteries in the presence of magnetic field. The elasticity of blood does not appear to influence its flow behavior under physiological conditions in the large arteries,purely viscous shear thinning model should be quite realistic for simulating blood flow under these conditions. On using the power law model with high shear rate for sinusoidal flow simulation in elastic arteries, the mean and amplitude of the flow rate were found to be lower for a power law fluid compared to Newtonian fluid for the same pressure gradient. The governing equations have been solved by Crank-Niclson scheme. The results are interpreted in the context of blood in the elastic arteries keeping the magnetic effects in view. For physiological flow simulation in the aorta, an increase in mean wall shear stress, but a reduction in peak wall shear stress were observed for power law model compared to a Newtonian fluid model for matched flow rate wave form. Blood flow in the presence of transverse magnetic field in an elastic artery is investigated and the influence of factors such as morphology and surface irregularity is evaluated.

  5. Blood flow and arterial endothelial dysfunction: Mechanisms and implications

    Science.gov (United States)

    Barakat, Abdul I.

    2013-06-01

    The arterial endothelium exquisitely regulates vascular function, and endothelial dysfunction plays a critical role in the development of atherosclerosis. Atherosclerotic lesions develop preferentially at arterial branches and bifurcations where the blood flow is disturbed. Understanding the basis for this observation requires elucidating the effects of blood flow on the endothelial cell (EC) function. The goal of this review is: (1) to describe our current understanding of the relationships between arterial blood flow and atherosclerosis, (2) to present the wide array of flow-induced biological responses in ECs, and (3) to discuss the mechanisms by which ECs sense, transmit, and transduce flow-derived mechanical forces. We conclude by presenting some future perspectives in the highly interdisciplinary field of EC mechanotransduction.

  6. Structured Tree Outflow Condition for Blood Flow in Arteries

    Science.gov (United States)

    Olufsen, Mette

    1998-11-01

    Modeling blood flow and especially propagation of the pulse wave in the systemic arteries is of interests to the medical society because of the significance of the dicrotic wave. The pulse wave propagating along the larger arteries is reflected because of tapering and branching of the vessels, as well as the peripheral resistance, which is mainly stemming from the smaller arteries and arterioles. In order to avoid artificial reflections it is important to determine a boundary condition, representing the smaller arteries and arterioles, which is physiologically correct. In this work we have proposed a boundary condition based on a structured tree model. The result will be compared both with other modeling approaches as well as with results from measurements of flow and pressure at a number of locations along the larger arteries. The model for the larger arteries is based on the axisymmetrical Navier Stokes equations where the blood is assumed Newtonian and incompressible and the vessels are tapering. In the structured tree the model is based on a linearization of the axisymmetrical Navier-Stokes equations. The reason for setting up a structured tree is that the smaller arteries consist of an almost binary tree. Furthermore, the role of the smaller arteries is to allow blood perfusion of specific tissues. This is done in a structured and optimal way such that the smaller arteries cover the tissue evenly using a minimization principle.

  7. Uterine artery blood flow, fetal hypoxia and fetal growth

    OpenAIRE

    Browne, Vaughn A.; Julian, Colleen G.; Toledo-Jaldin, Lillian; Cioffi-Ragan, Darleen; Vargas, Enrique; Moore, Lorna G.

    2015-01-01

    Evolutionary trade-offs required for bipedalism and brain expansion influence the pregnancy rise in uterine artery (UtA) blood flow and, in turn, reproductive success. We consider the importance of UtA blood flow by reviewing its determinants and presenting data from 191 normotensive (normal, n = 125) or hypertensive (preeclampsia (PE) or gestational hypertension (GH), n = 29) Andean residents of very high (4100–4300 m) or low altitude (400 m, n = 37). Prior studies show that UtA blood flow i...

  8. Changing blood flow in peripheral artery disease

    OpenAIRE

    Borne, P. van den

    2014-01-01

    Cardiovascular disease (CVD) is the leading cause of death globally and it is predicted this will remain to increase throughout 2030 to an estimated 23,3 million patients per year. This trend is accompanied by a steep increase in healthcare costs, making it a great health and socio-economic burden. The underlying pathology of CVD is often atherosclerosis, characterized by the development of atherosclerotic plaques in middle- and larger-sized arteries. Peripheral artery disease (PAD) is a dise...

  9. Nocturnal foot blood flow in patients with arterial insufficiency

    DEFF Research Database (Denmark)

    Jelnes, Rolf; Tønnesen, K H

    1984-01-01

    Twenty-four hour continuous recording of xenon (133Xe) wash-out from the forefoot was performed on patients with normal circulations (n = 10) and on patients with different degrees of arterial insufficiency (n = 36). During day hours the calculated subcutaneous blood flow in the forefoot was on a...

  10. Differences in superior thyroid artery and inferior thyroid artery blood flow spectrum parameters in subacute thyroiditis

    Institute of Scientific and Technical Information of China (English)

    Jin-Bo Li

    2016-01-01

    Objective:To study the differences in superior thyroid artery and inferior thyroid artery blood flow spectrum parameters in subacute thyroiditis. Methods:A Total of 40 cases of patients with subacute thyroiditis and 40 cases of healthy volunteers were selected for study and enrolled in pathology group and control group respectively, color Doppler ultrasonography was conducted to detect peak blood flow velocities (Vmax) of superior thyroid artery and inferior thyroid artery as well as resistance index (RI), and serum was collected to detect thyroid hormone contents, infection indexes and oxidative stress indexes. Results:Peak blood flow velocities Vmax of superior thyroid artery and inferior thyroid artery of pathology group were significantly higher than those of control group, and resistance index RI was not different from that of control group;FT3, FT4, TT3, TT4, ESR, CRP, PCT and MDA of pathology group were significantly higher than those of control group, and SOD and TAOC were significantly lower than those of control group;Vmax of superior thyroid artery and inferior thyroid artery were positively correlated with FT3, FT4, TT3, TT4, ESR, CRP, PCT and MDA, and negatively correlated with SOD and TAOC. Conclusion:Peak blood flow velocities (Vmax) of superior thyroid artery and inferior thyroid artery in subacute thyroiditis are significantly accelerated, Vmax has good consistency with thyroid hormone contents, infection indexes and oxidative stress indexes, and it can accurately assess the severity of the disease.

  11. Pulmonary blood flow distribution in transposition of the great arteries

    International Nuclear Information System (INIS)

    Pulmonary blood flow distribution was studied by scintillation scanning of the lungs after the infusion of iodine-131-labeled macroaggregates of human albumin before and after the Mustard operation in 53 patients with transposition of the great arteries. The patients were classified as follows: Group 1 (24 infants with uncomplicated transposition of the great arteries); Group II (18 patients with transposition and ventricular septal defect); and Group III (11 patients with transposition, ventricular septal defect and pulmonary obstruction). Before operation, 21 patients had a normal distribution of pulmonary blood flow, 10 had preferential flow to the right lung and 2 had preferential flow to the left lung. After operation, 19 had a normal pattern of pulmonary blood flow, 21 had preferential flow to the right lung and 3 had preferential flow to the left lung. The scanning studies have proved helpful in follow-up of patients to rule out recurrence of the shunt, pulmonary or systemic venous obstruction, development of pulmonary hypertension and occlusion of a palliative systemic-pulmonary shunt

  12. Deoxygenation Reduces Sickle Cell Blood Flow at Arterial Oxygen Tension.

    Science.gov (United States)

    Lu, Xinran; Wood, David K; Higgins, John M

    2016-06-21

    The majority of morbidity and mortality in sickle cell disease is caused by vaso-occlusion: circulatory obstruction leading to tissue ischemia and infarction. The consequences of vaso-occlusion are seen clinically throughout the vascular tree, from the relatively high-oxygen and high-velocity cerebral arteries to the relatively low-oxygen and low-velocity postcapillary venules. Prevailing models of vaso-occlusion propose mechanisms that are relevant only to regions of low oxygen and low velocity, leaving a wide gap in our understanding of the most important pathologic process in sickle cell disease. Progress toward understanding vaso-occlusion is further challenged by the complexity of the multiple processes thought to be involved, including, but not limited to 1) deoxygenation-dependent hemoglobin polymerization leading to impaired rheology, 2) endothelial and leukocyte activation, and 3) altered cellular adhesion. Here, we chose to focus exclusively on deoxygenation-dependent rheologic processes in an effort to quantify their contribution independent of the other processes that are likely involved in vivo. We take advantage of an experimental system that, to our knowledge, uniquely enables the study of pressure-driven blood flow in physiologic-sized tubes at physiologic hematocrit under controlled oxygenation conditions, while excluding the effects of endothelium, leukocyte activation, adhesion, inflammation, and coagulation. We find that deoxygenation-dependent rheologic processes are sufficient to increase apparent viscosity significantly, slowing blood flow velocity at arterial oxygen tension even without additional contributions from inflammation, adhesion, and endothelial and leukocyte activation. We quantify the changes in apparent viscosity and define a set of functional regimes of sickle cell blood flow personalized for each patient that may be important in further dissecting mechanisms of in vivo vaso-occlusion as well as in assessing risk of patient

  13. Dopexamine increases internal mammary artery blood flow following coronary artery bypass grafting.

    LENUS (Irish Health Repository)

    Flynn, Michael J

    2012-02-03

    OBJECTIVE: Vasoactive agents and inotropes influence conduit-coronary blood flow following coronary artery bypass grafting (CABG). It was hypothesized that dopexamine hydrochloride, a dopamine A-1 (DA-1) and beta(2) agonist would increase conduit-coronary blood flow. A prospective randomized double blind clinical trial was carried out to test this hypothesis. DA-1 receptors have previously been localized to human left ventricle. METHODS: Twenty-six American Society of Anaesthesiology class 2-3 elective coronary artery bypass graft patients who did not require inotropic support on separation from cardiopulmonary bypass (CPB) were studied. According to a randomized allocation patients received either dopexamine (1 microg\\/kg per min) or placebo (saline) by intravenous infusion for 15 min. Immediately prior to and at 5,10 and 15 min of infusion, blood flow through the internal mammary and vein grafts (Transit time flow probes, Transonic Ltd.), heart rate, cardiac index, mean arterial pressure and pulmonary haemodynamics were noted. The data were analysed using multivariate analysis of variance. RESULTS: Low-dose dopexamine (1 microg\\/kg per min) caused a significant increase in mammary graft blood flow compared to placebo at 15 min of infusion (P=0.028, dopexamine group left internal mammary artery (LIMA) flow of 43.3+\\/-14.2 ml\\/min, placebo group LIMA flow at 26.1+\\/-16.3 ml\\/min). Dopexamine recipients demonstrated a non-significant trend to increased saphenous vein graft flow (P=0.059). Increased heart rate was the only haemodynamic change induced by dopexamine (P=0.004, dopexamine group at 85.2+\\/-9.6 beats\\/min and placebo group at 71.1+\\/-7.6 beats\\/min after 15 min of infusion). CONCLUSION: This study demonstrates that administration of dopexamine (1 microg\\/kg per min) was associated with a significant increase in internal mammary artery graft blood flow with mild increase in heart rate being the only haemodynamic change. Low-dose dopexamine may

  14. Effect of TIPS placement on portal and splanchnic arterial blood flow in 4-dimensional flow MRI

    Energy Technology Data Exchange (ETDEWEB)

    Stankovic, Zoran [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Roessle, Martin; Schultheiss, Michael [University Medical Center Freiburg, Department of Gastroenterology, Freiburg (Germany); Euringer, Wulf; Langer, Mathias [University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Salem, Riad; Barker, Alex; Carr, James; Collins, Jeremy D. [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States)

    2015-09-15

    To assess changes in portal and splanchnic arterial haemodynamics in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) using four-dimensional (4D) flow MRI, a non-invasive, non-contrast imaging technique. Eleven patients undergoing TIPS implantation were enrolled. K-t GRAPPA accelerated non-contrast 4D flow MRI of the liver vasculature was applied with acceleration factor R = 5 at 3Tesla. Flow analysis included three-dimensional (3D) blood flow visualization using time-resolved 3D particle traces and semi-quantitative flow pattern grading. Quantitative evaluation entailed peak velocities and net flows throughout the arterial and portal venous (PV) systems. MRI measurements were taken within 24 h before and 4 weeks after TIPS placement. Three-dimensional flow visualization with 4D flow MRI revealed good image quality with minor limitations in PV flow. Quantitative analysis revealed a significant increase in PV flow (562 ± 373 ml/min before vs. 1831 ± 965 ml/min after TIPS), in the hepatic artery (176 ± 132 ml/min vs. 354 ± 140 ml/min) and combined flow in splenic and superior mesenteric arteries (770 ml/min vs. 1064 ml/min). Shunt-flow assessment demonstrated stenoses in two patients confirmed and treated at TIPS revision. Four-dimensional flow MRI might have the potential to give new information about the effect of TIPS placement on hepatic perfusion. It may explain some unexpected findings in clinical observation studies. (orig.)

  15. Effect of TIPS placement on portal and splanchnic arterial blood flow in 4-dimensional flow MRI

    International Nuclear Information System (INIS)

    To assess changes in portal and splanchnic arterial haemodynamics in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) using four-dimensional (4D) flow MRI, a non-invasive, non-contrast imaging technique. Eleven patients undergoing TIPS implantation were enrolled. K-t GRAPPA accelerated non-contrast 4D flow MRI of the liver vasculature was applied with acceleration factor R = 5 at 3Tesla. Flow analysis included three-dimensional (3D) blood flow visualization using time-resolved 3D particle traces and semi-quantitative flow pattern grading. Quantitative evaluation entailed peak velocities and net flows throughout the arterial and portal venous (PV) systems. MRI measurements were taken within 24 h before and 4 weeks after TIPS placement. Three-dimensional flow visualization with 4D flow MRI revealed good image quality with minor limitations in PV flow. Quantitative analysis revealed a significant increase in PV flow (562 ± 373 ml/min before vs. 1831 ± 965 ml/min after TIPS), in the hepatic artery (176 ± 132 ml/min vs. 354 ± 140 ml/min) and combined flow in splenic and superior mesenteric arteries (770 ml/min vs. 1064 ml/min). Shunt-flow assessment demonstrated stenoses in two patients confirmed and treated at TIPS revision. Four-dimensional flow MRI might have the potential to give new information about the effect of TIPS placement on hepatic perfusion. It may explain some unexpected findings in clinical observation studies. (orig.)

  16. Volumetric liquid flow measurement through thermography to simulate blood flow in an artery

    Science.gov (United States)

    Villaseñor-Mora, Carlos; Rabell-Montiel, Adela; González-Vega, Arturo; Gutierrez-Juarez, Gerardo

    2015-09-01

    Encouraged to improve the procedure to measure the blood flow in cases with peripheral artery disease using thermography, that allows to evaluate several arteries simultaneously, it was developed an alternative to measure the volumetric flow through a conduit, it was studied the variation of the thermal energy computed from thermal images due to changes in flow at different temperatures, and it was observed that the measurement is not strongly influenced by the emissivity of the conduit, the ambient temperature and humidity, but that is necessary to establish an adequate calibration of the camera to can use it as measurement instrument.

  17. ASSESSMENT OF VERTEBRAL ARTERIES BLOOD FLOW SPECTRAL DOPPLER INDICES IN COMPARISON WITH INTERNAL AND COMMON CAROTID ARTERIES BLOOD FLOW SPECTRAL DOPPLER INDICES

    Directory of Open Access Journals (Sweden)

    H. Mazaher

    2007-05-01

    Full Text Available Vertebrobasilar insufficiency is the cause of cerebrovascular accidents in 20% of cases. There are few reports regarding spectral Doppler indices (SDIs of vertebral arteries (VAs normal blood flow. The objective of this study was to provide basic reference data about SDIs of VAs normal blood flow separately and in comparison with internal carotid arteries (ICAs and common carotid arteries (CCAs normal blood flows SDIs. This cross-sectional study performed on 70 normal patients. Color Doppler sonography (CDS and spectral Doppler sonography (SDS of right and left VAs (RVA and LVA, right and left CCAs (RCCA and LCCA, right and left ICAs (RICA and LICA, were performed. The mean PSV, EDV, and RI values of RVA blood flow were as 41.60 ± 9.6 cm/s, 14.60 ± 3.7 cm/s and 0.65 ± 0.06, and the mean PSV, EDV and RI values of LVA blood flow were as 42.20 ± 10.2 cm/s, 15.20 ± 4.2 cm/s, and 0.64 ± 0.05, respectively. There was not statistically significant difference between the mean PSV, EDV and RI values of RVA and LVA blood flows. The mean PSV and EDV values of VAs blood flows were significantly lower than the values of CCAs and ICCAs blood flows, respectively. The mean RI value of VAs blood flows was significantly lower than the mean RI Value of CCAs blood flows, but there was not statistically significant difference between the mean RI value of VAs blood flows and the mean RI value of ICAs blood flows.

  18. Effect of blood flow parameters on flow patterns at arterial bifurcations--studies in models.

    Science.gov (United States)

    Liepsch, D W

    1990-01-01

    Atherosclerotic lesions are found primarily at arterial bends and bifurcations. Flow disturbances at these anatomic sites play a major role in atherogenesis. How hemodynamic factors such as vessel geometry, the pulsatile nature of blood flow, vessel wall elasticity and the non-Newtonian flow behavior of blood influence the flow field at these sites must be clarified. We have performed fundamental studies using a birefringent solution in a simplified rigid 90 degree T-bifurcation and pulsatile flow. The velocity distribution was measured with a laser Doppler anemometer. Flow in an elastic abdominal aorta model has been visualized using magnetic resonance imaging. In both flow studies, zones with negative velocity were found. These model measurements demonstrate that no flow parameter can be neglected. Further detailed studies are necessary to examine the interaction between fluid dynamic and cellular surface properties. PMID:2404201

  19. Transvaginal color Doppler ultrasound of ovarian artery blood flow in healthy women of reproductive age

    International Nuclear Information System (INIS)

    Objective: To provide reference standard for physiological and pathological changes of ovarian blood flow. Methods: Color Doppler ultrasound of ovarian artery blood flow was performed on 50 healthy women of reproductive age. Ovarian artery peak systolic velocity (PSV), end-diastolic velocity (EDV), blood flow resistant index (RI), pulsatility index (PI), and systolic end diastolic ratio (S/D) were studied in the follicular, ovulation, luteal and luteal atrophy phases. Results: There was a significant difference (P<0.05) among the ovarian artery EDV, RI, PI, S/D of different groups except for the highest (P<0.05). Conclusion: There are cyclical ovarian artery blood flow changes in healthy women of reproductive age. There is close relation between the blood supply and the functional status of the ovaries. (authors)

  20. Middle cerebral artery blood velocity and cerebral blood flow and O2 uptake during dynamic exercise

    DEFF Research Database (Denmark)

    Madsen, P L; Sperling, B K; Warming, T; Schmidt, J F; Secher, N H; Wildschiødtz, Gordon; Holm, S; Lassen, N A

    1993-01-01

    Results obtained by the 133Xe clearance method with external detectors and by transcranial Doppler sonography (TCD) suggest that dynamic exercise causes an increase of global average cerebral blood flow (CBF). These data are contradicted by earlier data obtained during less-well-defined conditions....... To investigate this controversy, we applied the Kety-Schmidt technique to measure the global average levels of CBF and cerebral metabolic rate of oxygen (CMRO2) during rest and dynamic exercise. Simultaneously with the determination of CBF and CMRO2, we used TCD to determine mean maximal flow...... velocity in the middle cerebral artery (MCA Vmean). For values of CBF and MCA Vmean a correction for an observed small drop in arterial PCO2 was carried out. Baseline values for global CBF and CMRO2 were 50.7 and 3.63 ml.100 g-1.min-1, respectively. The same values were found during dynamic exercise...

  1. [Synchonization of the blood flow rate in arterial with the changing rate of space of blood pressure with time].

    Science.gov (United States)

    Zhang, Shenghua; Qin, Renjia

    2012-10-01

    In physiology-related books, there are many relationship curves about blood flow rate in arteries and blood pressure changes with time, but there are not much explanation about such relationship. This is the very the question that the present article tries to answer. We clarified the relations between blood flow rate and blood pressure gradient using the experimental curves as the basis, using Poiseuille Law and relative knowledge of phisics and mathematics, and using analysis and reasoning. Based on the study, it can be concluded that in every course of cardiac cycle, the blood flow rate of any section in artery blood vessel is roughly synchronized with changing rate of space and time of the blood pressure, but blood flow rate is not synchronized with blood pressure. PMID:23198422

  2. Slip Effects on Pulsatile Flow of Blood through a Stenosed Arterial Segment under Periodic Body Acceleration

    OpenAIRE

    Sinha, A; Shit, G. C.; Kundu, P.K.

    2013-01-01

    A theoretical investigation concerning the influence of externally imposed periodic body acceleration on the flow of blood through a time-dependent stenosed arterial segment by taking into account the slip velocity at the wall of the artery has been carried out. A mathematical model is developed by treating blood as a non-Newtonian fluid obeying the Casson fluid model. The pulsatile flow is analyzed by considering a periodic pressure gradient and the inertial effects as negligibly small. A su...

  3. Prospect for vaginal delivery of growth restricted fetuses with abnormal umbilical artery blood flow.

    OpenAIRE

    Li, Hui; Gudmundsson, Saemundur; Olofsson, Per

    2003-01-01

    Background. The best mode of delivery in cases of intrauterine growth restriction (IUGR) with umbilical artery blood flow changes is not well elucidated. Objective. To evaluate outcome in IUGR with umbilical artery blood flow changes planned for vaginal delivery after a negative oxytocin challenge test (OCT). Methods. In 84 term singleton pregnancies with suspected IUGR and no unanimous indication for abdominal delivery, Doppler velocimetry and OCT were performed. Positive OCT c...

  4. Use of phase-contrast magnetic resonance angiography to measure blood flow in the ophthalmic artery

    International Nuclear Information System (INIS)

    The aim of this study was to examine the usefulness of phase-contrast magnetic resonance (MR) angiography (PC-MRA) to measure blood flow in the ophthalmic artery. PC-MRA was performed in 16 volunteers with no ophthalmic abnormalities and measurement of blood flow based on the results was attempted. It was possible to measure blood flow in the ophthalmic artery using PC-MRA in all 16 volunteers. The mean (±1 standard deviation) velocity was 9.17±2.28 cm/second, peak systolic velocity was 16.69±3.33 cm/second, and end diastolic velocity was 3.69±2.44 cm/second. The resistivity index was 0.79±0.12, the pulsatility index was 1.49±0.41, and flow was 6.25±2.33 ml/minute. It was possible to identify the ophthalmic artery and a portion of the artery in which blood flow could be measured using MR imaging, a preliminary step to blood flow measurement using MR angiography. In addition to the velocity of blood flow in the ophthalmic artery, measurement of the amount of flow was possible with PC-MRA, which is one advantage of this method. (author)

  5. EFFECT OF MAGNETIC FIELD ON BLOOD FLOW THROUGH AN ARTERY: A NUMERICAL MODEL

    OpenAIRE

    J Misra; Shit, G.

    2007-01-01

    In this paper we have investigated the unsteady flow of blood by treating it as an incompressible, Newtonian, electrically conducting fluid in a straight segment of an elastic artery subject to a uniform transverse magnetic field. The problem is solved numerically with the theoretical assumption of 'local flow' model [?]. A sinusoidal variation of the arterial wall motion and a pulsatile pressure gradient have been studied. An implicit finite difference technique is used to analyze the flow. ...

  6. The effect of phenylephrine on arterial and venous cerebral blood flow in healthy subjects

    DEFF Research Database (Denmark)

    Ogoh, Shigehiko; Sato, Kohei; Fisher, James P; Seifert, Thomas; Overgaard, Morten; Secher, Niels H

    2011-01-01

    Sympathetic regulation of the cerebral circulation remains controversial. Although intravenous phenylephrine (PE) infusion reduces the near-infrared spectroscopy (NIRS)-determined measure of frontal lobe oxygenation (S(c) O(2) ) and increases middle cerebral artery mean blood velocity (MCA V(mean......(mean) ), suggesting α-adrenergic-mediated cerebral vasoconstriction, this remains unconfirmed by evaluation of arterial and venous cerebral blood flow.......Sympathetic regulation of the cerebral circulation remains controversial. Although intravenous phenylephrine (PE) infusion reduces the near-infrared spectroscopy (NIRS)-determined measure of frontal lobe oxygenation (S(c) O(2) ) and increases middle cerebral artery mean blood velocity (MCA V...

  7. Assessment of Normal Vertebral Arteries Vs. Normal Internal Carotid and Common Carotid Arteries Blood Flow Spectral Doppler Indices

    Directory of Open Access Journals (Sweden)

    Sh. Sharif Kashani

    2005-08-01

    Full Text Available Introduction & Background: Vertebrobasilar insufficiency is the main cause of cerebrovascular accidents (CVAs in 20% of cases. There are few reports regarding spectral Doppler indices (SDIs of vertebral arteries (VAs normal blood flow. The objective of this study is to provide basic reference data about SDIs of VAs nor-mal blood flow separately, and in comparison with internal and common carotid arteries (ICAs and CCAs normal blood flows SDIs, for better and earlier detection of disordered SDIs of these arteries blood flow. Patients & Methods: This cross-sectional study was performed in Amir Alam hospital by three radiologists ex-perienced in vascular color Doppler sonography (CDS and spectral Doppler sonography (SDS from February 2002 till March 2004, on 70 normal patients. CDS and SDS of right and left vertebral arteries (RVA and LVA, right and left common carotid arteries (RCCA and LCCA, and right and left internal carotid arteries (RICA and LICA were performed. SDIs consisted of peak systolic velocity (PSV, end- diastolic velocity (EDV, and resistive index (RI values of these arteries blood flows and were assessed and compared with one another. Fi-nally all data was collected in SPSS version 12 software, and analyzed with the Student's T-test. Results: In this study, the mean PSV, EDV, and RI values of RVA blood flow were respectively 41.60 ± 9.6 cm/s, 14.60 ± 3.7 cm/s and 0.65 ± 0.06; the mean PSV, EDV and RI values of LVA blood flow were respectively 42.20 ± 10.2 cm/s, 15.20 ± 4.2 cm/s, and 0.64 ± 0.05. There was not statistically significant difference between the mean PSV, EDV, and RI values of RVA and LVA blood flows (P value > 0.1. The mean PSV and EDV val-ues of VAs blood flows were significantly lower than the mean PSV and EDV values of CCAs and ICCAs blood flows respectively (p-value 0.05.

  8. A simple model of cerebral blood flow dependence on arterial blood pressure

    CERN Document Server

    Gersten, Alexander

    2011-01-01

    It is shown that the dependence of the cerebral blood flow (CBF) on mean arterial blood pressure (MABP) can be described with a simple model having the following assumptions. Below certain MABP (denoted as MABP1) there are no autoregulatory or feedback mechanisms influencing CBF. Between MABP1 and MABP2 (MABP at which breakthrough accurs) there is a linear (on MABP) dependent feedback with a sloap depending very much on the individual considered. The classical autoregulation model with a plateau in between MABP1 and MABP2 is a particular case of this model. The model describes well the experiments performed on dogs (Harper 1966), for which the individual feedback sloap parameter varied to great extent, indicating the importance of mesurments on individuals against averaged mesurments (or measurments on diffent individuals) which superficially support the classical autoregulation. New effect of decreased CBF, while increasing MABP, was observed.

  9. Blood Flow Imaging in Maternal and Fetal Arteries and Veins

    Science.gov (United States)

    Ricci, S.; Urban, G.; Vergani, P.; Paidas, M. J.; Tortoli, P.

    Maternal and fetal blood circulation has been investigated for nearly a decade through ultrasound (US) techniques. Evaluation of the spectrogram related to a single sample volume has been proven valuable for the assessment of fetal well-being and for prediction of pregnancy complications. In this work, an alternative technique, called Multigate Spectral Doppler Analysis (MSDA), is proposed. In this approach, 128 sample volumes aligned along the same scan line are simultaneously investigated to detect the blood velocity profile with high resolution. Profiles obtained through MSDA reveal features not detectable with the standard US technique, thus representing a more accurate flow signature. Some preliminary illustrative results are reported here.

  10. Slip effects on unsteady non-Newtonian blood flow through an inclined catheterized overlapping stenotic artery

    Science.gov (United States)

    Zaman, Akbar; Ali, Nasir; Sajid, M.

    2016-01-01

    Slip effects on unsteady non-Newtonian blood hydro-magnetic flow through an inclined catheterized overlapping stenotic artery are analyzed. The constitutive equation of power law model is employed to simulate the rheological characteristics of the blood. The governing equations giving the flow derived by assuming the flow to be unsteady and two-dimensional. Mild stenosis approximation is employed to obtain the reduced form of the governing equations. Finite difference method is employed to obtain the solution of the non-linear partial differential equation in the presence of slip at the surface. An extensive quantitative analysis is performed for the effects of slip parameter, Hartmann number, cathetered parameter and arterial geometrical parameters of stenosis on the quantities of interest such as axial velocity, flow rate, resistance impedance and wall shear stress. The streamlines for the blood flow through the artery are also included.

  11. Slip effects on unsteady non-Newtonian blood flow through an inclined catheterized overlapping stenotic artery

    Directory of Open Access Journals (Sweden)

    Akbar Zaman

    2016-01-01

    Full Text Available Slip effects on unsteady non-Newtonian blood hydro-magnetic flow through an inclined catheterized overlapping stenotic artery are analyzed. The constitutive equation of power law model is employed to simulate the rheological characteristics of the blood. The governing equations giving the flow derived by assuming the flow to be unsteady and two-dimensional. Mild stenosis approximation is employed to obtain the reduced form of the governing equations. Finite difference method is employed to obtain the solution of the non-linear partial differential equation in the presence of slip at the surface. An extensive quantitative analysis is performed for the effects of slip parameter, Hartmann number, cathetered parameter and arterial geometrical parameters of stenosis on the quantities of interest such as axial velocity, flow rate, resistance impedance and wall shear stress. The streamlines for the blood flow through the artery are also included.

  12. Blood flow changes after unilateral carotid artery ligation monitored by optical coherence tomography

    Science.gov (United States)

    Ma, Yushu; Liang, Chengbo; Suo, Yanyan; Zhao, Yuqian; Wang, Yi; Xu, Tao; Wang, Ruikang; Ma, Zhenhe

    2016-03-01

    Unilateral carotid artery ligation which could induce adaptive improvement is a classic model that has been widely used to study pathology of ischemic disease. In those studies, blood flow is an important parameter to characterize the ischemia. Optical coherence tomography (OCT) is a powerful imaging modality which can provide depth resolved images in biological tissue with high spatial and temporal resolution. SPF rats was anesthetized with isoflurane and divided into two groups. In first group, bilateral carotid artery was surgically exposed, and then left carotid artery was ligated. Blood flow changes of the contralateral carotid artery was monitored using high speed spectral domain optical coherence tomography, including the absolute flow velocity and the flow volume. In the other group, skull window was opened at the ipsilateral cerebral cortex of ligation and blood supply of small artery was measured before and after the ligation. The measured results demonstrate the blood supply compensation process after unilateral carotid artery ligation. With the superiority of high resolution, OCT is an effective technology in monitoring results of carotid artery after ligation.

  13. Middle cerebral artery blood velocity during rowing

    DEFF Research Database (Denmark)

    Secher, Niels Henry; Pott, F; Knudsen, L.;

    1997-01-01

    original,arterial blood pressure,central venous pressure,cerebral blood flow, exercise, transcranial Doppler......original,arterial blood pressure,central venous pressure,cerebral blood flow, exercise, transcranial Doppler...

  14. The effect of captopril on the superior mesenteric artery and portal venous blood flow in normal man.

    OpenAIRE

    Ray-Chaudhuri, K; Thomaides, T; Maule, S; Watson, L.; Lowe, S; Mathias, C J

    1993-01-01

    1. Measurements of superior mesenteric artery and portal venous blood flow were made non-invasively along with systemic and other regional (cardiac index, forearm and cutaneous blood flow) vascular responses to acute ingestion of the ACE inhibitor captopril (50 mg) or placebo (50 mg vitamin C), in 12 healthy subjects while supine and during head-up tilt. 2. After captopril, superior mesenteric artery and portal blood flow rose markedly with a reduction in superior mesenteric artery vascular r...

  15. EFFECT OF ACUPUNCTURE ON BLOOD FLOW OF VERTEBRAL AND BASILAR ARTERIES IN STROKE PATIENTS

    Institute of Scientific and Technical Information of China (English)

    吕建明; 王伟志

    2004-01-01

    Objective: To observe the short-term effect and long-term effect of acupuncture on blood flow of vertebral and basilar arteries in stroke patients.Methods: A total of 58 stroke patients (34 males and 24 females) were agreed to participate in this study, and changes of blood flow of the vertebral and basilar arteries were detected after one week's and 45 days' continuous acupuncture treatment by using a Doppler's ultrasonic diagnosis apparatus.Bilateral Fengchi (GB 20), Wangu (GB 12), Tianzhu (BL 10), etc.were punctured and stimulated with small amplitude, high frequency and twirling-reinforcing method for 3 min.The treatment was conducted once daily.Results: Following one week's and 45 days' acupuncture treatment, diastolic velocity (DV), systolic velocity (SV) and mean velocity (MV) of the basilar artery increased significantly in comparison with pre-treatment (P0.05).Results indicated that acupuncture treatment could effectively improve blood supply of the basilar artery and regulate the uneven blood flow of the bilateral vertebral arteries.Conclusion: Acupuncture treatment can raise blood flow of the brain in stroke patients.

  16. Vasoactive enzymes and blood flow responses to passive and active exercise in peripheral arterial disease

    DEFF Research Database (Denmark)

    Walker, Meegan A.; Høier, Birgitte; Walker, Philip J.;

    2016-01-01

    than CON (1.04 ± 0.19 vs 0.50 ± 0.06 AU, P = 0.02), with no differences for other enzymes. Leg blood flow during exercise was correlated with prostacyclin synthase (P = 0.001). Conclusion: Elevated NADPH oxidase indicates that oxidative stress may be a primary cause of low nitric oxide availability......Background: Peripheral arterial disease (PAD) is characterised by impaired leg blood flow, which contributes to claudication and reduced exercise capacity. This study investigated to what extent vasoactive enzymes might contribute to altered blood flow in PAD (Fontaine stage II). Methods: We...... compared femoral artery blood flow during reactive hyperaemia, leg-extension exercise and passive leg movement, and determined the level of vasoactive enzymes in skeletal muscle samples from the vastus lateralis in PAD (n = 10, 68.5 ± 6.5 years) and healthy controls (CON, n = 9, 62.1 ± 12.3 years). Leg...

  17. Relaxin mediates uterine artery compliance during pregnancy and increases uterine blood flow.

    Science.gov (United States)

    Vodstrcil, Lenka A; Tare, Marianne; Novak, Jacqueline; Dragomir, Nicoleta; Ramirez, Rolando J; Wlodek, Mary E; Conrad, Kirk P; Parry, Laura J

    2012-10-01

    Normal pregnancy involves dramatic remodeling of the uterine vasculature, with abnormal vascular adaptations contributing to pregnancy diseases such as preeclampsia. The peptide hormone relaxin is important for the renal and systemic hemodynamic adaptations to pregnancy, and has been shown to increase arterial compliance and outward hypertrophic remodeling. Therefore, we investigated the possibility that relaxin acts on its receptor, RXFP1, to mediate uterine artery compliance in late pregnancy and increase uterine blood flow velocity in rats. RXFP1 was predominantly localized to the tunica media vascular smooth muscle cells in the uterine artery, although receptors were also detected in endothelial cells. Highest expression of Rxfp1 in the uterine artery occurred in estrus and early pregnancy. Isolated uterine arteries from late pregnant rats treated with a monoclonal antibody against circulating relaxin (MCA1) had significantly increased vessel wall stiffness compared with controls, with no reduction in wall thickness. Chronic infusion of relaxin (4 μg/h, osmotic minipump) for 5 d in nonpregnant rats significantly increased uterine artery blood flow velocity. Overall, these data demonstrate a functional role for relaxin in mediating uterine artery compliance in pregnant rats, which may be necessary to maintain adequate uterine blood flow to the uterus and placenta. PMID:22744867

  18. Blood flow redistribution and ventilation-perfusion mismatch during embolic pulmonary arterial occlusion

    OpenAIRE

    Burrowes, K. S.; Clark, A. R.; Tawhai, M.H

    2011-01-01

    Acute pulmonary embolism causes redistribution of blood in the lung, which impairs ventilation/perfusion matching and gas exchange and can elevate pulmonary arterial pressure (PAP) by increasing pulmonary vascular resistance (PVR). An anatomically-based multi-scale model of the human pulmonary circulation was used to simulate pre- and post-occlusion flow, to study blood flow redistribution in the presence of an embolus, and to evaluate whether reduction in perfused vascular bed is sufficient ...

  19. Changes in cerebral artery blood flow velocity after intermittent cerebrospinal fluid drainage.

    OpenAIRE

    Kempley, S T; Gamsu, H R

    1994-01-01

    Doppler ultrasound was used to measure blood flow velocity in the anterior cerebral artery of six premature infants with posthaemorrhagic hydrocephalus, before and after intermittent cerebrospinal fluid (CSF) drainage, on 23 occasions. There was a significant increase in mean blood flow velocity after the drainage procedures (+5.6 cm/s, 95% confidence interval +2.9 to +8.3 cm/s), which was accompanied by a decrease in velocity waveform pulsatility. CSF pressure also fell significantly. In pat...

  20. Mathematical Modelling of Blood Flow through a Tapered Overlapping Stenosed Artery with Variable Viscosity

    OpenAIRE

    Shit, G. C.; Roy, M.; Sinha, A

    2014-01-01

    This paper presents a theoretical study of blood flow through a tapered and overlapping stenosed artery under the action of an externally applied magnetic field. The fluid (blood) medium is assumed to be porous in nature. The variable viscosity of blood depending on hematocrit (percentage volume of erythrocytes) is taken into account in order to improve resemblance to the real situation. The governing equation for laminar, incompressible and Newtonian fluid subject to the boundary conditions ...

  1. Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

    OpenAIRE

    Shit, G. C.; Roy, M.; Sinha, A

    2012-01-01

    This paper presents a theoretical study of blood flow through a tapered and overlapping stenosed artery under the action of an externally applied magnetic field. The fluid (blood) medium is assumed to be porous in nature. The variable viscosity of blood depending on hematocrit (percentage volume of erythrocytes) is taken into account in order to improve resemblance to the real situation. The governing equation for laminar, incompressible and Newtonian fluid subject to the boundary conditions ...

  2. The effects of fenoldopam on coronary conduit blood flow after coronary artery bypass graft surgery.

    LENUS (Irish Health Repository)

    Halpenny, M

    2012-02-03

    OBJECTIVE: To quantify the effects of fenoldopam, 0.1 microg\\/kg\\/min, on left internal mammary artery (LIMA) and saphenous vein blood flow after coronary anastomosis. DESIGN: Prospective, randomized, double-blind, placebo-controlled trial. SETTING: University teaching hospital, single institution. PARTICIPANTS: Thirty-one American Society of Anesthesiologists III patients undergoing elective coronary revascularization. INTERVENTIONS: A perivascular ultrasonic flow probe (Linton Instrumentation, Norfolk, UK) was placed around the LIMA and saphenous vein graft after coronary anastomosis. MEASUREMENTS AND MAIN RESULTS: Immediately before and at 5-minute intervals for 15 minutes after starting the infusion, blood flow was measured in the LIMA and one saphenous vein graft using a transit time ultrasonic flow probe. Heart rate, blood pressure, and central venous pressure were documented at these time points. Administration of fenoldopam, 0.1 microg\\/kg\\/min, did not alter heart rate or blood pressure. A small, nonsignificant increase in LIMA blood flow occurred during the 15-minute study period (30 +\\/- 12 to 35 +\\/- 10 mL\\/min) in patients who received fenoldopam. No significant changes occurred in the placebo group. CONCLUSIONS: The findings indicate that fenoldopam, 0.1 microg\\/kg\\/min, did not influence coronary conduit blood flow to a clinically significant extent. The small increase in LIMA blood flow may be of greater importance in high-risk patients or in the prevention of coronary arterial spasm.

  3. Patient-specific coronary artery blood flow simulation using myocardial volume partitioning

    Science.gov (United States)

    Kim, Kyung Hwan; Kang, Dongwoo; Kang, Nahyup; Kim, Ji-Yeon; Lee, Hyong-Euk; Kim, James D. K.

    2013-03-01

    Using computational simulation, we can analyze cardiovascular disease in non-invasive and quantitative manners. More specifically, computational modeling and simulation technology has enabled us to analyze functional aspect such as blood flow, as well as anatomical aspect such as stenosis, from medical images without invasive measurements. Note that the simplest ways to perform blood flow simulation is to apply patient-specific coronary anatomy with other average-valued properties; in this case, however, such conditions cannot fully reflect accurate physiological properties of patients. To resolve this limitation, we present a new patient-specific coronary blood flow simulation method by myocardial volume partitioning considering artery/myocardium structural correspondence. We focus on that blood supply is closely related to the mass of each myocardial segment corresponding to the artery. Therefore, we applied this concept for setting-up simulation conditions in the way to consider many patient-specific features as possible from medical image: First, we segmented coronary arteries and myocardium separately from cardiac CT; then the myocardium is partitioned into multiple regions based on coronary vasculature. The myocardial mass and required blood mass for each artery are estimated by converting myocardial volume fraction. Finally, the required blood mass is used as boundary conditions for each artery outlet, with given average aortic blood flow rate and pressure. To show effectiveness of the proposed method, fractional flow reserve (FFR) by simulation using CT image has been compared with invasive FFR measurement of real patient data, and as a result, 77% of accuracy has been obtained.

  4. Instability of the middle cerebral artery blood flow in response to CO2.

    Directory of Open Access Journals (Sweden)

    Rosemary E Regan

    Full Text Available BACKGROUND: The middle cerebral artery supplies long end-artery branches to perfuse the deep white matter and shorter peripheral branches to perfuse cortical and subcortical tissues. A generalized vasodilatory stimulus such as carbon dioxide not only results in an increase in flow to these various tissue beds but also redistribution among them. We employed a fast step increase in carbon dioxide to detect the dynamics of the cerebral blood flow response. METHODOLOGY/PRINCIPAL FINDINGS: The study was approved by the Research Ethics Board of the University Health Network at the University of Toronto. We used transcranial ultrasound to measure the time course of middle cerebral artery blood flow velocity in 28 healthy adults. Normoxic, isoxic step increases in arterial carbon dioxide tension of 10 mmHg from both hypocapnic and normocapnic baselines were produced using a new prospective targeting system that enabled a more rapid step change than has been previously achievable. In most of the 28 subjects the responses at both carbon dioxide ranges were characterised by more complex responses than a single exponential rise. Most responses were characterised by a fast initial response which then declined rapidly to a nadir, followed by a slower secondary response, with some showing oscillations before stabilising. CONCLUSIONS/SIGNIFICANCE: A rapid step increase in carbon dioxide tension is capable of inducing instability in the cerebral blood flow control system. These dynamic aspects of the cerebral blood flow responses to rapid changes in carbon dioxide must be taken into account when using transcranial blood flow velocity in a single artery segment to measure cerebrovascular reactivity.

  5. Modeling blood flow circulation in intracranial arterial networks: a comparative 3D/1D simulation study.

    Science.gov (United States)

    Grinberg, L; Cheever, E; Anor, T; Madsen, J R; Karniadakis, G E

    2011-01-01

    We compare results from numerical simulations of pulsatile blood flow in two patient-specific intracranial arterial networks using one-dimensional (1D) and three-dimensional (3D) models. Specifically, we focus on the pressure and flowrate distribution at different segments of the network computed by the two models. Results obtained with 1D and 3D models with rigid walls show good agreement in massflow distribution at tens of arterial junctions and also in pressure drop along the arteries. The 3D simulations with the rigid walls predict higher amplitude of the flowrate and pressure temporal oscillations than the 1D simulations with compliant walls at various segments even for small time-variations in the arterial cross-sectional areas. Sensitivity of the flow and pressure with respect to variation in the elasticity parameters is investigated with the 1D model. PMID:20661645

  6. The blood flow in the posterior communicant artery. Angiographic study by using magnetic resonance

    CERN Document Server

    Portela, L A P

    1995-01-01

    did not change the direction of flow present, in the circumstances of this study. The arterial circle of Willis is the most important collateral pathway for the cerebral vessels when one the afferents is occluded. Its normal function, without vascular compromise, has been considered in conflicting ways in the literature. For centuries after its description by Thomas Willis in 1664 it was considered a flow equalizer, with free admixture of blood within it. Since the beginning of this century the dominant view is one of a potential value only, with null effective flow in the communicating arteries. The premise is included in different experimental models. Alternatively, it was considered that the normal direction of flow is antero-posterior, from carotid to posterior cerebral, since carotid flow is greater. Using phase-contrast magnetic resonance angiography, a non-invasive qualitative method, it was found in 40 patients without morphological brain abnormality and in 10 healthy volunteers that flow can be seen ...

  7. Two-Fluid Mathematical Models for Blood Flow in Stenosed Arteries: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2009-01-01

    Full Text Available The pulsatile flow of blood through stenosed arteries is analyzed by assuming the blood as a two-fluid model with the suspension of all the erythrocytes in the core region as a non-Newtonian fluid and the plasma in the peripheral layer as a Newtonian fluid. The non-Newtonian fluid in the core region of the artery is assumed as a (i Herschel-Bulkley fluid and (ii Casson fluid. Perturbation method is used to solve the resulting system of non-linear partial differential equations. Expressions for various flow quantities are obtained for the two-fluid Casson model. Expressions of the flow quantities obtained by Sankar and Lee (2006 for the two-fluid Herschel-Bulkley model are used to get the data for comparison. It is found that the plug flow velocity and velocity distribution of the two-fluid Casson model are considerably higher than those of the two-fluid Herschel-Bulkley model. It is also observed that the pressure drop, plug core radius, wall shear stress and the resistance to flow are significantly very low for the two-fluid Casson model than those of the two-fluid Herschel-Bulkley model. Hence, the two-fluid Casson model would be more useful than the two-fluid Herschel-Bulkley model to analyze the blood flow through stenosed arteries.

  8. Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

    CERN Document Server

    Shit, G C; Sinha, A

    2012-01-01

    This paper presents a theoretical study of blood flow through a tapered and overlapping stenosed artery under the action of an externally applied magnetic field. The fluid (blood) medium is assumed to be porous in nature. The variable viscosity of blood depending on hematocrit (percentage volume of erythrocytes) is taken into account in order to improve resemblance to the real situation. The governing equation for laminar, incompressible and Newtonian fluid subject to the boundary conditions is solved by using a well known Frobenius method. The analytical expressions for velocity component, volumetric flow rate, wall shear stress and pressure gradient are obtained. The numerical values are extracted from these analytical expressions and are presented graphically. It is observed that the influence of hematocrit, magnetic field and the shape of artery have important impact on the velocity profile, pressure gradient and wall shear stress. Moreover, the effect of primary stenosis on the secondary one has been sig...

  9. Mathematical Modelling of Blood Flow through a Tapered Overlapping Stenosed Artery with Variable Viscosity

    Directory of Open Access Journals (Sweden)

    G. C. Shit

    2014-01-01

    Full Text Available This paper presents a theoretical study of blood flow through a tapered and overlapping stenosed artery under the action of an externally applied magnetic field. The fluid (blood medium is assumed to be porous in nature. The variable viscosity of blood depending on hematocrit (percentage volume of erythrocytes is taken into account in order to improve resemblance to the real situation. The governing equation for laminar, incompressible and Newtonian fluid subject to the boundary conditions is solved by using a well known Frobenius method. The analytical expressions for velocity component, volumetric flow rate, wall shear stress and pressure gradient are obtained. The numerical values are extracted from these analytical expressions and are presented graphically. It is observed that the influence of hematocrit, magnetic field and the shape of artery have important impact on the velocity profile, pressure gradient and wall shear stress. Moreover, the effect of primary stenosis on the secondary one has been significantly observed.

  10. Measurements of cerebral blood flow in vertebrobasilar artery territory determined by direct injection of 133Xe

    International Nuclear Information System (INIS)

    Direct injection of 133Xe has been used for measurements of cerebral blood flow (CBF) in internal carotid arterial territory, but little is known as to whether this technique can be utilized for measurements of CBF within the vertebrobasilar artery system. This study investigated a validity of 133Xe injection into the vertebral artery for CBF measurement of infratentorium. A catheter was inserted into either left or right vertebral artery through the femoral artery under florescopic control to directly inject 1 - 2 mCi of 133Xe. Similar catheter procedures were used for CBF measurement for the internal carotid artery. Four probes as well as seven probes fitted with colimaters of 40 mm length and 17 mm diameter were placed respectively over posterior fossa and cerebral hemisphere. Cerebral blood flow values for vertebrobasilar arterial system (V-CBF) and for internal carotid arterial system (I-CBF) were calculated from the initial part of clearrance curves. Measurements were made in 7 patients with infra-tentorial stroke. The patients' clinical severities were of different degrees. The results obtained could be summarized as follows: (1) The more severe the grade of disturbed consciousness, the more apparent the decrease of V-CBF. (2) In patients with mild disturbance of consciousness, the decrease of V-CBF was more prominent compared to I-CBF. (3) In comatose or semicomatose patients. I-CBF and V-CBF were markedly reduced showing indentical values. These results indicate the possibility and clinical usefulness of V-CBF measurement in stroke patients. (author)

  11. Hemoglobin, hematocrit, and changes in cerebral blood flow : The Second Manifestations of ARTerial disease-Magnetic Resonance study

    NARCIS (Netherlands)

    van der Veen, Pieternella H.; Muller, Majon; Vincken, Koen L.; Westerink, Jan; Mali, Willem P. T. M.; van der Graaf, Yolanda; Geerlings, Mirjam I.; Doevendans, PAFM

    2015-01-01

    Hemoglobin and hematocrit are important determinants of blood viscosity and arterial oxygen content and may therefore influence cerebral blood flow (CBF). We examined cross-sectional and prospective associations of hemoglobin and hematocrit with CBF in 569 patients with manifest arterial disease (me

  12. Exercise intensity modulates brachial artery retrograde blood flow and shear rate during leg cycling in hypoxia.

    Science.gov (United States)

    Iwamoto, Erika; Katayama, Keisho; Ishida, Koji

    2015-06-01

    The purpose of this study was to elucidate the effect of exercise intensity on retrograde blood flow and shear rate (SR) in an inactive limb during exercise under normoxic and hypoxic conditions. The subjects performed two maximal exercise tests on a semi-recumbent cycle ergometer to estimate peak oxygen uptake (V˙O2peak) while breathing normoxic (inspired oxygen fraction [FIO2 = 0.21]) and hypoxic (FIO2 = 0.12 or 0.13) gas mixtures. Subjects then performed four exercise bouts at the same relative intensities (30 and 60% V˙O2peak) for 30 min under normoxic or hypoxic conditions. Brachial artery diameter and blood velocity were simultaneously recorded, using Doppler ultrasonography. Retrograde SR was enhanced with increasing exercise intensity under both conditions at 10 min of exercise. Thereafter, retrograde blood flow and SR in normoxia returned to pre-exercise levels, with no significant differences between the two exercise intensities. In contrast, retrograde blood flow and SR in hypoxia remained significantly elevated above baseline and was significantly greater at 60% than at 30% V˙O2peak. We conclude that differences in exercise intensity affect brachial artery retrograde blood flow and SR during prolonged exercise under hypoxic conditions. PMID:26038470

  13. Blood flow modeling for patient-specific bypass surgery in lower-limb arteries

    OpenAIRE

    Willemet, Marie

    2012-01-01

    Every day in Belgium, at least one or two people will undergo a bypass surgery in the lower-limb arteries. This medical procedure consists of replacing an occluded section of the leg arteries with an artificial vessel, in order to allow blood to flow downwards of this blockage. Even though this intervention is very common, failure of this treatment within five years reaches up to 60%. In order to improve our understanding of the causes of bypass failure, one approach is to study the local hem...

  14. An effective fractal-tree closure model for simulating blood flow in large arterial networks.

    Science.gov (United States)

    Perdikaris, Paris; Grinberg, Leopold; Karniadakis, George Em

    2015-06-01

    The aim of the present work is to address the closure problem for hemodynamic simulations by developing a flexible and effective model that accurately distributes flow in the downstream vasculature and can stably provide a physiological pressure outflow boundary condition. To achieve this goal, we model blood flow in the sub-pixel vasculature by using a non-linear 1D model in self-similar networks of compliant arteries that mimic the structure and hierarchy of vessels in the meso-vascular regime (radii [Formula: see text]). We introduce a variable vessel length-to-radius ratio for small arteries and arterioles, while also addressing non-Newtonian blood rheology and arterial wall viscoelasticity effects in small arteries and arterioles. This methodology aims to overcome substantial cut-off radius sensitivities, typically arising in structured tree and linearized impedance models. The proposed model is not sensitive to outflow boundary conditions applied at the end points of the fractal network, and thus does not require calibration of resistance/capacitance parameters typically required for outflow conditions. The proposed model convergences to a periodic state in two cardiac cycles even when started from zero-flow initial conditions. The resulting fractal-trees typically consist of thousands to millions of arteries, posing the need for efficient parallel algorithms. To this end, we have scaled up a Discontinuous Galerkin solver that utilizes the MPI/OpenMP hybrid programming paradigm to thousands of computer cores, and can simulate blood flow in networks of millions of arterial segments at the rate of one cycle per 5 min. The proposed model has been extensively tested on a large and complex cranial network with 50 parent, patient-specific arteries and 21 outlets to which fractal trees where attached, resulting to a network of up to 4,392,484 vessels in total, and a detailed network of the arm with 276 parent arteries and 103 outlets (a total of 702,188 vessels

  15. Numerical simulation of blood pulsatile flow in a stenosed carotid artery using different rheological models.

    Science.gov (United States)

    Razavi, A; Shirani, E; Sadeghi, M R

    2011-07-28

    Symmetrical 30-60% stenosis in a common carotid artery under unsteady flow condition for Newtonian and six non-Newtonian viscosity models are investigated numerically. Results show power-law model produces higher deviations, in terms of velocity and wall shear stress in comparison with other models while generalized power-law and modified-Casson models are more prone to Newtonian state. Comparing separation length of recirculation region at different critical points of cardiac cycle confirms the necessity of considering blood flow in unsteady mode. Increasing stenosis intensity causes flow patterns more disturbed downstream of the stenosis and WSS appear to develop remarkably at the stenosis throat. PMID:21696742

  16. Intrapericardial denervation - Radial artery blood flow and heart rate responses to LBNP

    Science.gov (United States)

    Mckeever, Kenneth H.; Skidmore, Michael G.; Keil, Lanny C.; Sandler, Harold

    1990-01-01

    The effects of intrapericardial denervation on the radial artery blood flow velocity (RABFV) and heart rate (HR) responses to LBNP in rhesus monkeys were investigated by measuring the RABFV transcutaneously by a continuous-wave Doppler ultrasonic flowmeter in order to derive an index of forearm blood flow response to low (0 to -20 mm Hg) and high (0 to -60 mm Hg) ramp exposures during supine LBNP. Four of the eight subjects were subjected to efferent and afferent cardiac denervation. It was found that, during low levels of LBNP, monkeys with cardiac denervation exhibited no cardiopulmonary baroreceptor-mediated change in the RABFV or HR, unlike the intact animals, which showed steady decreases in RABFV during both high- and low-pressure protocols. It is suggested that forearm blood flow and HR responses to low-level LBNP, along with pharmacological challenge, are viable physiological tests for verifying the completeness of atrial and cardiopulmonary baroreceptor denervation.

  17. Flow of non-Newtonian blood analog fluids in rigid curved and straight artery models.

    Science.gov (United States)

    Mann, D E; Tarbell, J M

    1990-01-01

    The influence of non-Newtonian rheology on wall shear rate in steady and oscillatory flow through rigid curved and straight artery models was studied experimentally. Wall shear rates measured by flush mounted hot film anemometry under nearly identical flow conditions are reported for the following four fluids: aqueous glycerin (Newtonian), aqueous polyacrylamide (shear thinning, highly elastic), aqueous Xanthan gum (shear thinning, moderately elastic), and bovine blood. For steady flow conditions there was little difference at any measurement site in the wall shear rate levels measured for the four fluids. However, large differences were apparent for oscillatory flows, particularly at the inner curvature 180 degrees from the entrance of the curved artery model. At that position the peak wall shear rate for polyacrylamide was 5-6 times higher than for glycerin and 2-3 times higher than for bovine blood. It is concluded that polyacylamide is too elastic to provide a good model of blood flow under oscillatory conditions, particularly when there is wall shear reversal. Xanthan gum and glycerin are better analog fluids, but neither is entirely satisfactory. PMID:2271763

  18. Computational modeling of non-Newtonian blood flow through stenosed arteries in the presence of magnetic field.

    Science.gov (United States)

    Alshare, Aiman; Tashtoush, Bourhan; El-Khalil, Hossam H

    2013-11-01

    Steady flow simulations of blood flow in an axisymmetric stenosed artery, subjected to a static magnetic field, are performed to investigate the influence of artery size, magnetic field strength, and non-Newtonian behavior on artery wall shear stress and pressure drop in the stenosed section. It is found that wall shear stress and pressure drop increase by decreasing artery size, assuming non-Newtonian fluid, and increasing magnetic field strength. In the computations, the shear thinning behavior of blood is accounted for by the Carreau-Yasuda model. Computational results are compared and found to be inline with available experimental data. PMID:24061603

  19. Numerical simulation of blood flow and pressure drop in the pulmonary arterial and venous circulation.

    Science.gov (United States)

    Qureshi, M Umar; Vaughan, Gareth D A; Sainsbury, Christopher; Johnson, Martin; Peskin, Charles S; Olufsen, Mette S; Hill, N A

    2014-10-01

    A novel multiscale mathematical and computational model of the pulmonary circulation is presented and used to analyse both arterial and venous pressure and flow. This work is a major advance over previous studies by Olufsen et al. (Ann Biomed Eng 28:1281-1299, 2012) which only considered the arterial circulation. For the first three generations of vessels within the pulmonary circulation, geometry is specified from patient-specific measurements obtained using magnetic resonance imaging (MRI). Blood flow and pressure in the larger arteries and veins are predicted using a nonlinear, cross-sectional-area-averaged system of equations for a Newtonian fluid in an elastic tube. Inflow into the main pulmonary artery is obtained from MRI measurements, while pressure entering the left atrium from the main pulmonary vein is kept constant at the normal mean value of 2 mmHg. Each terminal vessel in the network of 'large' arteries is connected to its corresponding terminal vein via a network of vessels representing the vascular bed of smaller arteries and veins. We develop and implement an algorithm to calculate the admittance of each vascular bed, using bifurcating structured trees and recursion. The structured-tree models take into account the geometry and material properties of the 'smaller' arteries and veins of radii ≥ 50 μm. We study the effects on flow and pressure associated with three classes of pulmonary hypertension expressed via stiffening of larger and smaller vessels, and vascular rarefaction. The results of simulating these pathological conditions are in agreement with clinical observations, showing that the model has potential for assisting with diagnosis and treatment for circulatory diseases within the lung. PMID:24610385

  20. Dependence of renal blood flow on renal artery stenosis measured using CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Luedemann, Lutz [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiotherapy; Nafz, B.; Persson, P. [Charite - Universitaetsmedizin Berlin (Germany). Inst. for Vegetative Physiology; Elsner, F. [Krankenhaus am Urban, Berlin (Germany). Dept. of Anesthesiology; Grosse-Siestrup, C.; Meissler, M. [Charite - Universitaetsmedizin Berlin (Germany). Experimental Animal Unit; Gutberlet, M. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Univ. Leipzig/ Leipzig Heart Center (Germany). Dept. of Diagnostic and Interventional Radiology; Lengsfeld, P.; Voth, M. [Bayer-Schering Pharma AG, Berlin (Germany). Global Medical Affairs Diagnostic Imaging

    2011-03-15

    The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)

  1. Heat stress redistributes blood flow in arteries of the brain during dynamic exercise.

    Science.gov (United States)

    Sato, Kohei; Oue, Anna; Yoneya, Marina; Sadamoto, Tomoko; Ogoh, Shigehiko

    2016-04-01

    We hypothesized that heat stress would decrease anterior and posterior cerebral blood flow (CBF) during exercise, and the reduction in anterior CBF would be partly associated with large increase in extracranial blood flow (BF). Nine subjects performed 40 min of semirecumbent cycling at 60% of the peak oxygen uptake in hot (35°C; Heat) and thermoneutral environments (25°C; Control). We evaluated BF and conductance (COND) in the external carotid artery (ECA), internal carotid artery (ICA), and vertebral artery (VA) using ultrasonography. During the Heat condition, ICA and VA BF were significantly increased 10 min after the start of exercise (PECA BF and COND at the end of Heat were both higher than levels in the Control condition (PECA BF during Heat was negatively correlated with a change in ICA BF (r= -0.75). Heat stress resulted in modification of the vascular response of head and brain arteries to exercise, which resulted in an alteration in the distribution of cardiac output. Moreover, a hyperthermia-induced increase in extracranial BF might compromise anterior CBF during exercise with heat stress. PMID:26846548

  2. Correlation between penile cavernosal artery blood flow and retinal vascular findings in arteriogenic erectile dysfunction

    Directory of Open Access Journals (Sweden)

    Ahmed M Emarah

    2010-09-01

    Full Text Available Ahmed M Emarah1, Shawky M El-Haggar2, Ihab A Osman2, Abdel Wahab S Khafagy21Departments of Ophthalmology, 2Andrology and Sexology, Cairo University Hospital, EgyptObjectives: Arteriogenic erectile dysfunction (ED is a target organ disease of atherosclerosis, and therefore might be a predictor of systemic atherosclerosis. Being systemic, it might be possible to evaluate the extent of atherosclerosis from retinal vascular findings. We investigated the possible correlation between penile cavernosal artery blood flow and retinal vascular findings in patients with arteriogenic ED.Patients and methods: Sixty patients with ED were divided according to the peak systolic velocity (PSV in their penile cavernosal arteries into two groups; Group A included 30 patients with PSV less than 25 cm/sec, and Group B included 30 patients with PSV more than 35 cm/sec. Blood flow in the penile cavernosal artery was measured with color Doppler ultrasonography. All patients were assessed by ocular fundus examination under amydriatic conditions to evaluate retinal vascular atherosclerotic changes using Hyman’s classification.Results: Evidence of retinal vascular atherosclerotic changes was found in 19 patients (63.3% in Group A and in 10 patients (33.3% in Group B.Conclusions: Our study confirms the possibility of predicting penile arterial vascular status in patients with ED from their retinal vascular findings by using amydriatic simple, practical funduscopy.Keywords: erectile dysfunction, atherosclerosis, retinal vascular atherosclerosis

  3. Fourier Analysis of Peripheral Blood Pressure and Flow in Intraoperative Assessment of Infrainguinal Arterial Reconstructions

    Directory of Open Access Journals (Sweden)

    Cheshmedzhiev Mihail V.

    2014-08-01

    Full Text Available AIM: To assess infrainguinal arterial reconstructions by intraoperative flowmetry under the distal anastomosis using a fast Fourier transformation; calculate and compare the amplitude ratios of peripheral arterial blood pressure and volume flow before and after drug-induced vasodilation of occluded bypass grafts and bypass grafts that have been patent at least for 1 year. To find what magnitude of the change of these ratios indicate a long-term patency of the bypass grafting. PATIENTS AND METHODS: We compared the results of the intraoperative flowmetry tests of 97 patients with infrainguinal arterial reconstructions. The patients were divided into two groups based on the graft status: the grafts in 49 patients were patent for at least a year, and 48 patients had failed bypass. We used a fast Fourier transform (FFT of the pressure and blood flow waves and compared the ratios of their amplitudes before and after administration of a vasodilator drug into the graft. Comparing the ratios obtained before and those after administration of the drug we quantified their change in each group and analysed them. RESULTS: After a drug-induced vasodilation, the blood pressure and flow amplitude ratios for the group with compromised reconstructions were less than 1.9 times smaller than those before drug infusion, while for the group with bypass grafts that had been functional for at least 12 months the ratios declined by more than 1.9≈2 times. CONCLUSION: The magnitude of the change of amplitude ratios of the peripheral pressure and volume flow after drug-induced vasodilation can be used to make an assessment of the bypass graft and the distal arterial segment.

  4. Comparison of obstructing blood flow interventional embolectomy and simple interventional embolectomy for acute lower limb arterial embolism

    International Nuclear Information System (INIS)

    Objective: To evaluate the effects (mortality, amputation rate, the length and expense of hospital stay, etc)of the obstructing blood flow interventional embolectomy and simple interventional embolectomy for acute lower limb arterial embolism. Methods: 79 cases of acute lower limb arterial embolism including 23 cases of two sites puncturing and obstructing blood flow interventional embolectomy and 56 cases treated by simple interventional embolectomy were retrospectively analyzed and compared. Results: Embolisms were removed in all 79 cases and arteries were reopened successfully. The mortality and the amputation rates of the simple and the obstructing blood flow embolectomies were 5.36%, 19.6%, and 4.35%, 8.70% respectively. Conclusion: Two sites puncturing and obstructing blood flow interventional embolectomy for acute lower limb arterial embolism is simple, safe and effective, comparing with the simple interventional embolectomy, with lower amputation rate, quicker recovery and lower expense, however with no statistical significance in mortalities. (authors)

  5. Wall morphology, blood flow and wall shear stress: MR findings in patients with peripheral artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Galizia, Mauricio S.; Barker, Alex; Collins, Jeremy; Carr, James [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Liao, Yihua [Northwestern University' s Feinberg School of Medicine, Department of Preventive Medicine, Chicago, IL (United States); McDermott, Mary M. [Northwestern University' s Feinberg School of Medicine, Department of Preventive Medicine, Chicago, IL (United States); Northwestern University' s Feinberg School of Medicine, Department of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States)

    2014-04-15

    To investigate the influence of atherosclerotic plaques on femoral haemodynamics assessed by two-dimensional (2D) phase-contrast (PC) magnetic resonance imaging (MRI) with three-directional velocity encoding. During 1 year, patients with peripheral artery disease and an ankle brachial index <1.00 were enrolled. After institutional review board approval and written informed consent, 44 patients (age, 70 ± 12 years) underwent common femoral artery MRI. Patients with contra-indications for MRI were excluded. Sequences included 2D time-of-flight, proton-density, T1-weighted and T2-weighted MRI. Electrocardiogram (ECG)-gated 2D PC-MRI with 3D velocity encoding was acquired. A radiologist classified images in five categories. Blood flow, velocity and wall shear stress (WSS) along the vessel circumference were quantified from the PC-MRI data. The acquired images were of good quality for interpretation. There were no image quality problems related to poor ECG-gating or slice positioning. Velocities, oscillatory shear stress and total flow were similar between patients with normal arteries and wall thickening/plaque. Patients with plaques demonstrated regionally increased peak systolic WSS and enhanced WSS eccentricity. Combined multi-contrast morphological imaging of the peripheral arterial wall with PC-MRI with three-directional velocity encoding is a feasible technique. Further study is needed to determine whether flow is an appropriate marker for altered endothelial cell function, vascular remodelling and plaque progression. (orig.)

  6. Wall morphology, blood flow and wall shear stress: MR findings in patients with peripheral artery disease

    International Nuclear Information System (INIS)

    To investigate the influence of atherosclerotic plaques on femoral haemodynamics assessed by two-dimensional (2D) phase-contrast (PC) magnetic resonance imaging (MRI) with three-directional velocity encoding. During 1 year, patients with peripheral artery disease and an ankle brachial index <1.00 were enrolled. After institutional review board approval and written informed consent, 44 patients (age, 70 ± 12 years) underwent common femoral artery MRI. Patients with contra-indications for MRI were excluded. Sequences included 2D time-of-flight, proton-density, T1-weighted and T2-weighted MRI. Electrocardiogram (ECG)-gated 2D PC-MRI with 3D velocity encoding was acquired. A radiologist classified images in five categories. Blood flow, velocity and wall shear stress (WSS) along the vessel circumference were quantified from the PC-MRI data. The acquired images were of good quality for interpretation. There were no image quality problems related to poor ECG-gating or slice positioning. Velocities, oscillatory shear stress and total flow were similar between patients with normal arteries and wall thickening/plaque. Patients with plaques demonstrated regionally increased peak systolic WSS and enhanced WSS eccentricity. Combined multi-contrast morphological imaging of the peripheral arterial wall with PC-MRI with three-directional velocity encoding is a feasible technique. Further study is needed to determine whether flow is an appropriate marker for altered endothelial cell function, vascular remodelling and plaque progression. (orig.)

  7. Uterine artery blood flow in the periimplantation period in embryo transfer cycles

    Institute of Scientific and Technical Information of China (English)

    Ursula Zollner; Marie-Theres Specketer; Klaus-Peter Zollner; Johannse Dietl

    2012-01-01

    Objective:To assess the role of the uterine artery blood flow in the prediction of implantation in women undergoing embryo transfer during the periimplantation period.Methods:A total of 233 couples were included in this prospective study.All patients had embryo transfer,125 were performed inin-vitro fertilization/intracytoplasmic sperm injection(IVF/ICSI) and108 in cryo cycles.Ultrasound measurements were performed immediately before transfer.The pulsatility index(PI),Resistance index(RI) and the peak systolic velocity(PSV) were measured in both uterine arteries using endovaginal ultrasound.Results:InIVF/ICSI cycles the doppler parameters PI(2.48vs.2.15),RI(0.78vs.1.30) andPSV(60 vs.63) did not differ significantly between the pregnant and non-pregnant group.The pregnancy rate per transfer was similar in women showing an unilateral(24%), bilateral(33%) or no(27%) notch in the uterine blood flow.In cryo cycles the uterine artery blood flow parametersPI(3.2vs.3.0),RI(0.9vs.0.9) andPSV(53.2vs.51.2) did not differ either between pregnant and not pregnant patients.Conclusions:Previous studies were aiming at the measurement of arterial doppler parameters during the follicular phase which may not be adequate for the prediction of implantation.However, our results show that doppler studies during the early luteal phase of assisted reproductive technology cycles are not indicative for the likelihood of pregnancy, too.

  8. Evaluation of changes of intracranial blood flow after carotid artery stenting using digital subtraction angiography flow assessment

    Institute of Scientific and Technical Information of China (English)

    Hajime; Wada; Masato; Saito; Kyousuke; Kamada

    2015-01-01

    AIM: To evaluate the changes of intracranial blood flow after carotid artery stenting(CAS), using the flow assessment application "Flow-Insight", which was developed in our department.METHODS: Twenty patients treated by CAS participated in this study. We analyzed the change in concentration of the contrast media at the anterior-posterior and profile view image with the flow assessment application "Flow-Insight". And we compared the results with N-isopropyl-p-[123I] iodoamphetamine-single-photon emission computed tomography(IMP SPECT) performed before and after the treatment. RESULTS: From this study, 200% of the parameter "blood flow" change in the post/pre-treatment is suggested as the critical line of the hyperperfusion syndrome arise. Although the observed blood flow increase in the digital subtraction angiography system did not strongly correlate with the rate of increase of SPECT, the "Flow-Insight" reflected the rate of change of the vessels well. However, for patients with reduced reserve blood flow before CAS, a highly elevated site was in agreement with the site analysis results. CONCLUSION: We concluded that the cerebral angiography flow assessment application was able to more finely reveal hyperperfusion regions in the brain after CAS compared to SPECT.

  9. Simulation of the Second Grade Fluid Model for Blood Flow through a Tapered Artery with a Stenosis

    Science.gov (United States)

    Nadeem, S.; Noreen Sher, Akbar

    2010-06-01

    We analyze the blood flow through a tapered artery, assuming the blood to be a second order fluid model. The resulting nonlinear implicit system of partial differential equations is solved by the perturbation method. The expressions for shear stress, velocity, flow rate, wall shear stress and longitudinal impedance are obtained. The physical behavior of different parameters is also discussed, as are trapping phenomena.

  10. A model for investigating the control of muscle blood flow: the masseteric artery in conscious rabbits

    International Nuclear Information System (INIS)

    The complex interplay of neural, metabolic, myogenic and mechanical mechanisms that regulate blood flow in skeletal muscle (MBF) is still incompletely understood. For the first time, a method is presented for high time-resolution recording of MBF from a purely muscular artery in physiological conditions. Ultrasound perivascular flow probes were implanted (n = 15) mono- or bilaterally around the masseteric branch of the facial artery in nine rabbits and tested up to 16 days after implant. Reliable and stable recordings were achieved in 50% of implants. Blood flow was observed to increase from a resting level of 0.2–0.3 ml min−1 up to 4.0–6.0 ml min−1 during spontaneous masticatory activity. In addition, within single masticatory cycles marked back flow transients could be observed (peak flow = −10 ml min−1) during powerful masticatory strokes but not during mild mastication. The possibility of (1) surgically removing the sympathetic supply to the relevant vascular bed and of (2) bilaterally monitoring the perfusion of masseter muscles thus allowing to use one side as control side for different types of interventions makes this model a useful tool for disentangling the different mechanisms involved in the control of MBF. (note)

  11. Supine exercise restores arterial blood pressure and skin blood flow despite dehydration and hyperthermia.

    Science.gov (United States)

    González-Alonso, J; Mora-Rodríguez, R; Coyle, E F

    1999-08-01

    We determined whether the deleterious effects of dehydration and hyperthermia on cardiovascular function during upright exercise were attenuated by elevating central blood volume with supine exercise. Seven trained men [maximal oxygen consumption (VO(2 max)) 4.7 +/- 0. 4 l/min (mean +/- SE)] cycled for 30 min in the heat (35 degrees C) in the upright and in the supine positions (VO(2) 2.93 +/- 0.27 l/min) while maintaining euhydration by fluid ingestion or while being dehydrated by 5% of body weight after 2 h of upright exercise. When subjects were euhydrated, esophageal temperature (T(es)) was 37. 8-38.0 degrees C in both body postures. Dehydration caused equal hyperthermia during both upright and supine exercise (T(es) = 38. 7-38.8 degrees C). During upright exercise, dehydration lowered stroke volume (SV), cardiac output, mean arterial pressure (MAP), and cutaneous vascular conductance and increased heart rate and plasma catecholamines [30 +/- 6 ml, 3.0 +/- 0.7 l/min, 6 +/- 2 mmHg, 22 +/- 8%, 14 +/- 2 beats/min, and 50-96%, respectively; all P < 0. 05]. In contrast, during supine exercise, dehydration did not cause significant alterations in MAP, cutaneous vascular conductance, or plasma catecholamines. Furthermore, supine versus upright exercise attenuated the increases in heart rate (7 +/- 2 vs. 9 +/- 1%) and the reductions in SV (13 +/- 4 vs. 21 +/- 3%) and cardiac output (8 +/- 3 vs. 14 +/- 3%) (all P < 0.05). These results suggest that the decline in cutaneous vascular conductance and the increase in plasma norepinephrine concentration, independent of hyperthermia, are associated with a reduction in central blood volume and a lower arterial blood pressure. PMID:10444482

  12. Evaluation of MR angiography and blood flow measurement in abdominal and peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    To assess the characteristics of blood flow measurement with MR Angiography (MRA) to evaluate the status of vascular stenoses, two or three dimensional time-of-flight MRA and velocity-encoded cine MR were performed in the 230 segments of 35 patients, with abdominal and peripheral arterial occlusive diseases. In 11 of these 35 patients digital subtraction angiography was additionally underwent, and the stenotic findings was compared with MRA. There were 17 segments in which the velocity could not be measured, because the blood flow exceeded the upper limit of peak-encoded velocity (VENC) which was set at 120 cm/sec. Therefore, it is necessary to set the upper limit of VENC at higher than 120 cm/sec. There were 11 stenotic findings in DSA and 20 stenotic findings in MRA. Pulsatility Index (PI=(max velocity-min. velocity)/average velocity) were used for evaluating the blood flow waveform, and there were significant difference between the 11 stenotic findings of DSA and the others'. In summery, MRA was considered as useful examination to assess the degree of the vascular stenoses in abdominal and peripheral arterial occlusive disease. (author)

  13. Evaluation of MR angiography and blood flow measurement in abdominal and peripheral arterial occlusive disease

    Energy Technology Data Exchange (ETDEWEB)

    Tabuchi, Kenji [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-03-01

    To assess the characteristics of blood flow measurement with MR Angiography (MRA) to evaluate the status of vascular stenoses, two or three dimensional time-of-flight MRA and velocity-encoded cine MR were performed in the 230 segments of 35 patients, with abdominal and peripheral arterial occlusive diseases. In 11 of these 35 patients digital subtraction angiography was additionally underwent, and the stenotic findings was compared with MRA. There were 17 segments in which the velocity could not be measured, because the blood flow exceeded the upper limit of peak-encoded velocity (VENC) which was set at 120 cm/sec. Therefore, it is necessary to set the upper limit of VENC at higher than 120 cm/sec. There were 11 stenotic findings in DSA and 20 stenotic findings in MRA. Pulsatility Index (PI=(max velocity-min. velocity)/average velocity) were used for evaluating the blood flow waveform, and there were significant difference between the 11 stenotic findings of DSA and the others'. In summery, MRA was considered as useful examination to assess the degree of the vascular stenoses in abdominal and peripheral arterial occlusive disease. (author)

  14. Assessment of tissue blood flow following small artery welding with an intraluminal dissolvable stent.

    Science.gov (United States)

    He, F C; Wei, L P; Lanzetta, M; Owen, E R

    1999-01-01

    Using the technique of radioactive 51Cr-labeled biological microspheres, this study evaluated arterial blood flow following small vessel anastomosis by CO2 laser welding and a dissolvable stent in the lumen. A total of 30 Sprague-Dawley rats were divided into two groups. Group A: 11 rats had their femoral arteries ligated on one side. The contralateral side served as a control, with the artery transected and repaired using conventional microsuturing. Group B: 19 rats had their femoral arteries transected and repaired using CO2 laser welding and an intraluminal dissolvable stent technique. The contralateral side was again used as a control using conventional microsuturing. At 1 hr postoperatively, 51Cr-labeled biological microspheres were injected centripetally into the left common carotid artery and the legs and thighs immediately harvested for measurement of radioactivity. All repaired arteries were patent (30/30 in the microsuturing group and 19/19 in the stented welding group), with no detectable stenosis or dilation at the repaired site. Statistical analysis showed that tissue radioactivity (cpm/g) in the ligated group (3,972 +/- 384 in thighs and 3,142 +/- 742 in legs) was significantly lower than in the microsuturing group (7,132 +/- 1,723 in thighs and 6,557 +/- 1,469 in legs) (P welding group, in both thighs (7,064 +/- 2,599 and 7,006 +/- 2,406, respectively; P > 0.05) and legs (6,386 +/- 1,703 and 6,288 +/- 1,757, respectively; P > 0.05). This study provided evidence that the dissolvable stent placed intraluminally does not impair blood circulation and that when coupled with CO2 laser welding offers a high-quality alternative to conventional small vessel anastomosis. PMID:10231124

  15. Evaluation of blood flow in Allograft Renal Arteries anastomosed with two different techniques

    International Nuclear Information System (INIS)

    Renal artery stenosis in renal transplantation (TRAS) is an avoidable short or long term surgical complication. The etiology is multifactorial, but faulty anastomosis is a major factor. In our transplant center, we evaluated the incidence of TRAS with the use of two different suturing techniques of the anastomosis site between allograft renal and renal and iliac arteries in two groups of renal transplant recipients, group A: 14 patients (6 males and 8 females with age 16 to 59 and mean age of 38 years) in whom allograft arteries were anastomosed with a continuous suture technique and group B: 14 patients (7 males and 7 females with age 32 to 61 and mean age of 46.6 years) in whom the allograft arteries were anastomosed with a combined suture technique (continuous and uninterrupted. Post transplantation, the velocity of blood flow in the renal and iliac arteries at the site of anastomosis was measured by color Doppler ultrasound. The ultrasonographer was blinded to the surgical technique in both study groups. The ratio of the maximum velocity of blood at the site of anastomosis to that in the iliac artery of less than 2.5 was considered as non-significant stenosis, while a ratio of more than 2.5 was considered significant stenosis. In group A there were 9 cases of non-significant stenosis in comparison to 3 cases in group B, while there were no cases of significant stenosis in group A in comparison to 3 cases in group B; the difference was not statistically significant. We conclude that there was no difference in the compared surgical techniques of anastomosis in our study groups. This suggests that other factors such as gentle handling of tissue, enough spatula, margin reversion and comparable diameter of the anastomosed vessels may be more important in the prevention of renal allograft stenosis than the type of suture technique. (author)

  16. Twenty-four-hour exposure to altered blood flow modifies endothelial Ca2+-activated K+ channels in rat mesenteric arteries

    DEFF Research Database (Denmark)

    Hilgers, Rob H P; Janssen, Ger M J; Fazzi, Gregorio E;

    2010-01-01

    We tested the hypothesis that changes in arterial blood flow modify the function of endothelial Ca2+-activated K+ channels [calcium-activated K+ channel (K(Ca)), small-conductance calcium-activated K+ channel (SK3), and intermediate calcium-activated K+ channel (IK1)] before arterial structural...

  17. Ratio between carotid artery stiffness and blood flow – a new ultrasound index of ischemic leukoaraiosis

    Directory of Open Access Journals (Sweden)

    Turk M

    2016-01-01

    Full Text Available Monika Turk, Marjan Zaletel, Janja Pretnar-OblakDepartment of Vascular Neurology and Intensive Neurological Therapy, University Medical Centre Ljubljana, Ljubljana, SloveniaBackground: Ischemic leukoaraiosis (ILA is associated with cognitive decline and aging. Its pathophysiology is believed to be ischemic in origin due to its association with cerebrovascular risk factors and similarity in location to lacunar infarctions. ILA diagnosis is still based on magnetic resonance imaging (MRI as well as exclusion of other causes of white matter hyperintensities. So far, there are no known confirming diagnostic tests of ILA. Ultrasound studies have recently shown increased large artery stiffness, increased cerebrovascular resistance, and lower cerebral blood flow in patients with ILA. Increased arterial stiffness and decreased blood flow could have a synergistic effect, and their ratio could be a useful diagnostic index of ILA.Methods: In this post hoc analysis, we introduced new ILA indices (ILAi that are ratios of the carotid stiffness parameters (pulse wave velocity beta [PWVβ], pressure–strain elasticity modulus [Ep], β index, and diastolic and mean blood flows in the internal carotid artery: Q-ICAd and Q-ICAm. We compared the ILAi of 52 patients with ILA and 44 sex- and risk factor-matched controls with normal MRI of the head. ILA diagnosis was based on MRI and exclusion of other causes of white matter hyperintensities. The diagnostic significance of ILAi for the prediction of ILA was analyzed.Results: All ILAi significantly differed between the groups; the most significant were PWVβ/Q-ICAd (ILA group: 1.96±0.64 vs control group: 1.56±0.40, P=0.001 and PWVβ/Q-ICAm (ILA group: 1.13±0.32 vs control group: 0.94±0.25, P=0.003. All ILAi were significantly associated with ILA (P<0.01 and were significant independent predictors of ILA. All ILAi were also sensitive and specific for predicting ILA (area under the curve: 0.632–0.683, P<0

  18. Middle cerebral artery flow velocity and blood flow during exercise and muscle ischemia in humans

    DEFF Research Database (Denmark)

    Jørgensen, L G; Perko, M; Hanel, B; Schroeder, T V; Secher, N H

    1992-01-01

    Changes in middle cerebral artery flow velocity (Vmean), measured by transcranial Doppler ultrasound, were used to determine whether increases in mean arterial pressure (MAP) or brain activation enhance cerebral perfusion during exercise. We also evaluated the role of "central command......," mechanoreceptors, and/or muscle "metaboreceptors" on cerebral perfusion. Ten healthy subjects performed two levels of dynamic exercise corresponding to a heart rate of 110 (range 89-134) and 148 (129-170) beats/min, respectively, and exhaustive one-legged static knee extension. Measurements were continued during 2......-2.5 min of muscle ischemia. MAP increased similarly during static [114 (102-133) mmHg] and heavy dynamic exercise [121 (104-136) mmHg] and increased during muscle ischemia after dynamic exercise. During heavy dynamic exercise, Vmean increased 24% (10-47%; P less than 0.01) over approximately 3 min despite...

  19. Differentiation between pulmonary thrombi and slow blood flow in the pulmonary artery by MR imaging

    International Nuclear Information System (INIS)

    On electrocardiogram (ECG)-gated spin-echo magnetic resonance (MR) images, differentiation of thrombi from slow blood flow in the pulmonary arteries (PA) is sometimes difficult in such cases with prominent pulmonary hypertension (PH) as they show high signal intensity of intraluminal slow flow in not only diastole but also systole. ECG-gated, double spin-echo MR images were obtained in eight patients with PH accompanied by the high signal intensity of blood flow in the right main PA in both diastole and systole. These images were compared with those of five patients with chronic pulmonary thromboembolism (CPTE). Slow flow, but not thrombi, significantly increased signal intensity relative to other tissues from the first-echo to the second-echo image. In two patients with both CPTE and PH discrimination between slow flow and central thrombi was established by this imaging technique. This study suggests that ECG-gated, double spin-echo technique is useful for differentiating central thrombi from slow flow. MR imaging can play an important role in detection and repeated noninvasive examination of proximal pulmonary thromboemboli. (author)

  20. Theoretical analysis of metallic nanoparticles on blood flow through stenosed artery with permeable walls

    International Nuclear Information System (INIS)

    The present analysis deals with the study of physical characteristics of blood flow in the presence of stenosis and nanoparticles through a curved channel with permeable walls. Taking mild stenosis case, the governing equations for anticipated model are solved using the corresponding boundary conditions and close-form solutions have been obtained for temperature, velocity and slip velocity by using Cauchy Euler's method. The expressions for the resistance impedance and pressure gradient in the stenotic region have also been obtained and the existence of various pertinent flow parameters, mainly Darcy number, slip parameter and nanoparticles volume fraction, has been discussed through graphs. - Highlights: • Nanoparticles analysis is discussed for diverging converging and non-tapered arteries. • Resistance impedance decreases with an increase in the nanoparticles volume fraction. • Combination of curvature and stenosis shows stenosis dominant the curvature of artery. • Pressure possesses an inverse variation to the resistance with respect to tapering. • Trapping shows that the symmetry destroys due to increase in curvature of curved artery

  1. Theoretical analysis of metallic nanoparticles on blood flow through stenosed artery with permeable walls

    Energy Technology Data Exchange (ETDEWEB)

    Nadeem, S.; Ijaz, S., E-mail: shaguftaijaz11@yahoo.com

    2015-03-06

    The present analysis deals with the study of physical characteristics of blood flow in the presence of stenosis and nanoparticles through a curved channel with permeable walls. Taking mild stenosis case, the governing equations for anticipated model are solved using the corresponding boundary conditions and close-form solutions have been obtained for temperature, velocity and slip velocity by using Cauchy Euler's method. The expressions for the resistance impedance and pressure gradient in the stenotic region have also been obtained and the existence of various pertinent flow parameters, mainly Darcy number, slip parameter and nanoparticles volume fraction, has been discussed through graphs. - Highlights: • Nanoparticles analysis is discussed for diverging converging and non-tapered arteries. • Resistance impedance decreases with an increase in the nanoparticles volume fraction. • Combination of curvature and stenosis shows stenosis dominant the curvature of artery. • Pressure possesses an inverse variation to the resistance with respect to tapering. • Trapping shows that the symmetry destroys due to increase in curvature of curved artery.

  2. A Computational Fluid Dynamic Study of Blood Flow Within the Coiled Umbilical Arteries

    Science.gov (United States)

    Wilke, David; Denier, James; Mattner, Trent; Khong, Yee

    2013-11-01

    The umbilical cord is the lifeline of the fetus throughout gestation. In a normal pregnancy it facilitates the supply of oxygen and nutrients from the placenta via a single vein, in addition to the return of deoxygenated blood from the developing embryo or fetus via two umbilical arteries. Despite the major role it plays in the growth of the fetus, pathologies of the umbilical cord are poorly understood. In particular, variations in the cord geometry, which typically forms a helical arrangement, have been correlated with adverse outcomes in pregnancy. Cords exhibiting either abnormally low or high levels of coiling have been associated with pathological results including growth-restriction and fetal demise. Despite this, the methodology currently employed by clinicians to characterize umbilical pathologies can misdiagnose cords and is prone to error. In this talk a computational model of blood flow within rigid three-dimensional structures representative of the umbilical arteries will be presented. This study determined that the current characterization was unable to differentiate between cords which exhibited clinically distinguishable flow properties, including the cord pressure drop, which provides a measure of the loading on the fetal heart.

  3. The analysis of MHD blood flows through porous arteries using a locally modified homogenous nanofluids model.

    Science.gov (United States)

    Akbarzadeh, Pooria

    2016-05-12

    In this paper, magneto-hydrodynamic blood flows through porous arteries are numerically simulated using a locally modified homogenous nanofluids model. Blood is taken into account as the third-grade non-Newtonian fluid containing nanoparticles. In the modified nanofluids model, the viscosity, density, and thermal conductivity of the solid-liquid mixture (nanofluids) which are commonly utilized as an effective value, are locally combined with the prevalent single-phase model. The modified governing equations are solved numerically using Newton's method and a block tridiagonal matrix solver. The results are compared to the prevalent nanofluids single-phase model. In addition, the efficacies of important physical parameters such as pressure gradient, Brownian motion parameter, thermophoresis parameter, magnetic-field parameter, porosity parameter, and etc. on temperature, velocity and nanoparticles concentration profiles are examined. PMID:27175464

  4. Changes in Hepatic Blood Flow During Transcatheter Arterial Infusion with Heated Saline in Hepatic VX2 Tumor

    International Nuclear Information System (INIS)

    Purpose. This study evaluates the influence of transcatheter arterial infusion with heated saline on hepatic arterial and portal venous blood flows to tumor and normal hepatic tissues in a rabbit VX2 tumor model. Methods. All animal experiments were approved by the institutional animal care and use committee. Twenty rabbits with VX2 liver tumors were divided into the following two groups: (a) the treated group (n = 10), which received a 60 mL transarterial injection of 60 °C saline via the hepatic artery; (b) the control group (n = 10), which received a 60 mL injection of 37 °C saline via the hepatic artery. Using ultrasonography, the blood flows in both the portal vein and hepatic artery were measured, and the changes in the hemodynamic indices were recorded before and immediately after the injection. The changes in the tumor and normal liver tissues of the two groups were histopathologically examined by hematoxylin and eosin staining after the injection. Results. After the transcatheter arterial heated infusion, there was a decrease in the hepatic arterial blood flow to the tumor tissue, a significant decrease in the hepatic artery mean velocity (P < 0.05), and a significant increase in the resistance index (P < 0.05). On hematoxylin and eosin staining, there were no obvious signs of tissue destruction in the normal liver tissue or the tumor tissue after heated perfusion, and coagulated blood plasma was observed in the cavities of intratumoral blood vessels in the treated group. Conclusions. The changes in tumor blood flow in the rabbit VX2 tumor model were presumably caused by microthrombi in the tumor vessels, and the portal vein likely mediated the heat loss in normal liver tissue during the transarterial heated infusion.

  5. Changes in Hepatic Blood Flow During Transcatheter Arterial Infusion with Heated Saline in Hepatic VX2 Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Cao Wei, E-mail: cawe-001@163.com [Tangdu Hospital, The Fourth Military Medical University, Department of Interventional Radiology (China); Li Jing, E-mail: lijing02@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Burn and Plastic Surgery (China); Wu Zhiqun, E-mail: zhiqunwu@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Interventional Radiology (China); Zhou Changxi, E-mail: changxizhou@163.com [Chinese PLA General Hospital, Department of Respiratory Disease (China); Liu Xi, E-mail: xiliu@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Ultrasound Diagnostics (China); Wan Yi, E-mail: yiwan@163.com [The Fourth Military Medical University, Department of Health Statistics, Institute for Health Informatics (China); Duan Yunyou, E-mail: yunyouduan@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Ultrasound Diagnostics (China)

    2013-06-15

    Purpose. This study evaluates the influence of transcatheter arterial infusion with heated saline on hepatic arterial and portal venous blood flows to tumor and normal hepatic tissues in a rabbit VX2 tumor model. Methods. All animal experiments were approved by the institutional animal care and use committee. Twenty rabbits with VX2 liver tumors were divided into the following two groups: (a) the treated group (n = 10), which received a 60 mL transarterial injection of 60 Degree-Sign C saline via the hepatic artery; (b) the control group (n = 10), which received a 60 mL injection of 37 Degree-Sign C saline via the hepatic artery. Using ultrasonography, the blood flows in both the portal vein and hepatic artery were measured, and the changes in the hemodynamic indices were recorded before and immediately after the injection. The changes in the tumor and normal liver tissues of the two groups were histopathologically examined by hematoxylin and eosin staining after the injection. Results. After the transcatheter arterial heated infusion, there was a decrease in the hepatic arterial blood flow to the tumor tissue, a significant decrease in the hepatic artery mean velocity (P < 0.05), and a significant increase in the resistance index (P < 0.05). On hematoxylin and eosin staining, there were no obvious signs of tissue destruction in the normal liver tissue or the tumor tissue after heated perfusion, and coagulated blood plasma was observed in the cavities of intratumoral blood vessels in the treated group. Conclusions. The changes in tumor blood flow in the rabbit VX2 tumor model were presumably caused by microthrombi in the tumor vessels, and the portal vein likely mediated the heat loss in normal liver tissue during the transarterial heated infusion.

  6. Dynamic CT imaging of intrahepatic arterial blood flow in patients with chronic liver disease

    International Nuclear Information System (INIS)

    Using dynamic CT, the parenchymal hemodynamics of the livers was studied in patients with chronic liver disease. Dynamic CT was performed on 34 patients: 8 cases of chronic inactive hepatitis (CIH), 15 cases of chronic active hepatitis (CAH) and 11 cases of liver cirrhosis (LC). After rapid intravenous administration of contrast medium (61.2% iopamidol, 20 ml), 25 consecutive scans of the liver and spleen were performed and imaged on a single slice. The single scan time was one sec. Then, the following program was performed: 15 scans at 2 sec intervals, 7 scans at 15 sec intervals and 3 scans at 20 sec intervals. The fit curve for a single pass of the medium was obtained from the analysis of time-density curves in the right and left lobes of the liver and the spleen using a gamma variate function and the least square method. Three parameters were measured on the fit curve: the peak time (PT) was defined as the time to peak enhancement, the total volume component (TVC) was defined as the area beneath the curve between the rise point and the PT point for each lobe of the liver, and the arterial flow volume component (AVC) was defined as the area beneath the curve between the rise point and the PT point of the spleen. AVC in the right liver lobe did not significantly differ between groups, but significantly differed in the manner of CIH< CAH< LC (p<0.05) in the left lobe of the liver. The ratio of intrahepatic arterial blood flow to total hepatic blood flow (AVC/TVC) did not significantly differ between groups in the right lobe. In the left liver lobe, however, AVC/TVC significantly differed in the manner of CIH≤CAH< LC (p<0.01), and was significantly higher in LC patients than in CIH or CAH patients. These results suggest that the ratio of intrahepatic arterial blood flow in the left liver lobe increases as chronic liver disease progresses. (author)

  7. Quantitative evaluation of cerebral blood flow by XeCT in stenting angioplasty for carotid artery

    International Nuclear Information System (INIS)

    Objective: To evaluate the hemodynamic characteristics of severe carotid artery stenosis and curative effect of stent angioplasty through XeCT. Methods: From April 2006 to November 2006, 13 patients with severe carotid artery stenoses underwent stent angioplasty in our hospital, including 11 male and 2 females, in an average age of 57.31 ± 6.12. All patients underwent XeCT examination to evaluate the quantitative cerebral blood flow (CBF). The ischemic cortex is categorized into 4 kinds, the normal region, oligemia area, reversible ischemic site and ischemic core center. Measurement and comparison of the changes were taken before and after the therapy. Results: Preoperative XeCT revealed different decrease of CBF in the ipsilateral cortex, especially in MCA distributing territory. Ischemic areas reduced significantly after the stenting angioplasty. Oligemia area reduced from 32.63% to 14.22%. Reversible ischemic area reduced from 13.54% to 8.38%. Normal area increased from 47.51% to 71.13%. But ischemic core center showed no significant changes. Conclusions: XeCT is beneficial for evaluation of the hemodynamic characteristics of carotid artery stenoses and also for accurately demonstrating the curative effects of the stent angioplasty. (authors)

  8. LES of non-Newtonian physiological blood flow in a model of arterial stenosis.

    Science.gov (United States)

    Molla, M M; Paul, M C

    2012-10-01

    Large Eddy Simulation (LES) is performed to study the physiological pulsatile transition-to-turbulent non-Newtonian blood flow through a 3D model of arterial stenosis by using five different blood viscosity models: (i) Power-law, (ii) Carreau, (iii) Quemada, (iv) Cross and (v) modified-Casson. The computational domain has been chosen is a simple channel with a biological type stenosis formed eccentrically on the top wall. The physiological pulsation is generated at the inlet of the model using the first four harmonic series of the physiological pressure pulse (Loudon and Tordesillas [1]). The effects of the various viscosity models are investigated in terms of the global maximum shear rate, post-stenotic re-circulation zone, mean shear stress, mean pressure, and turbulent kinetic energy. We find that the non-Newtonian viscosity models enlarge the length of the post-stenotic re-circulation region by moving the reattachment point of the shear layer separating from the upper wall further downstream. But the turbulent kinetic energy at the immediate post-lip of the stenosis drops due to the effects of the non-Newtonian viscosity. The importance of using LES in modelling the non-Newtonian physiological pulsatile blood flow is also assessed for the different viscosity models in terms of the results of the dynamic subgrid-scale (SGS) stress Smagorinsky model constant, C(s), and the corresponding SGS normalised viscosity. PMID:22153320

  9. Simulation of the Second Grade Fluid Model for Blood Flow through a Tapered Artery with a Stenosis

    International Nuclear Information System (INIS)

    We analyze the blood flow through a tapered artery, assuming the blood to be a second order fluid model. The resulting nonlinear implicit system of partial differential equations is solved by the perturbation method. The expressions for shear stress, velocity, flow rate, wall shear stress and longitudinal impedance are obtained. The physical behavior of different parameters is also discussed, as are trapping phenomena. (cross-disciplinary physics and related areas of science and technology)

  10. Influence of magnetic field and Hall currents on blood flow through a stenotic artery

    Institute of Scientific and Technical Information of China (English)

    Kh. S. Mekheimer; M.A. El Kot

    2008-01-01

    A micropolar model for blood simulating magnetohydrodynamic flow through a horizontally nonsymmetric but vertically symmetric artery with a mild stenosis is pre- sented. To estimate the effect of the stenosis shape, a suitable geometry has been consid- ered such that the horizontal shape of the stenosis can easily be changed just by varying a parameter referred to as the shape parameter. Flow parameters, such as velocity, the resistance to flow (the resistance impedance), the wall shear stress distribution in the stenotic region, and its magnitude at the maximum height of the stenosis (stenosis throat), have been computed for different shape parameters, the Hartmann number and the Hall parameter. This shows that the resistance to flow decreases with the increasing values of the parameter determining the stenosis shape and the Hall parameter, while it increases with the increasing Hartmann number. The wall shear stress and the shearing stress on the wall at the maximum height of the stenosis possess an inverse characteristic to the resistance to flow with respect to any given value of the Hartmann number and the Hall parameter. Finally, the effect of the Hartmann number and the Hall parameter on the horizontal velocity is examined.

  11. Magnetic resonance imaging-based computational modelling of blood flow and nanomedicine deposition in patients with peripheral arterial disease

    OpenAIRE

    Hossain, Shaolie S.; Zhang, Yongjie; Fu, Xiaoyi; Brunner, Gerd; Singh, Jaykrishna; Hughes, Thomas J.R.; Shah, Dipan; Decuzzi, Paolo

    2015-01-01

    Peripheral arterial disease (PAD) is generally attributed to the progressive vascular accumulation of lipoproteins and circulating monocytes in the vessel walls leading to the formation of atherosclerotic plaques. This is known to be regulated by the local vascular geometry, haemodynamics and biophysical conditions. Here, an isogeometric analysis framework is proposed to analyse the blood flow and vascular deposition of circulating nanoparticles (NPs) into the superficial femoral artery (SFA)...

  12. Dependency of cerebral blood flow upon mean arterial pressure in patients with acute bacterial meningitis

    DEFF Research Database (Denmark)

    Møller, Kirsten; Larsen, Fin Stolze; Qvist, Jesper;

    2000-01-01

    Diseases, Copenhagen University Hospital, Denmark. PATIENTS: Sixteen adult patients with acute bacterial meningitis. INTERVENTION: Infusion of norepinephrine to increase MAP. MEASUREMENTS: During a rise in MAP induced by norepinephrine infusion, we measured relative changes in CBF by transcranial Doppler......OBJECTIVE: Patients with acute bacterial meningitis are often treated with sympathomimetics to maintain an adequate mean arterial pressure (MAP). We studied the influence of such therapy on cerebral blood flow (CBF). DESIGN: Prospective physiologic trial. SETTING: The Department of Infectious....... Autoregulation was classified as impaired if Vmean increased by >10% per 30 mm Hg increase in MAP and if no lower limit of autoregulation was identified by the computer program; otherwise, autoregulation was classified as preserved. MAIN RESULTS: Initially, Vmean increased from a median value of 46 cm/sec (range...

  13. Arterial pressure and cerebral blood flow variability: friend or foe? A review

    Directory of Open Access Journals (Sweden)

    CarolineAliceRickards

    2014-04-01

    Full Text Available Variability in arterial pressure and cerebral blood flow has traditionally been interpreted as a marker of cardiovascular decompensation, and has been associated with negative clinical outcomes across varying time scales, from impending orthostatic syncope to an increased risk of stroke. Emerging evidence, however, suggests that increased hemodynamic variability may, in fact, be protective in the face of acute challenges to perfusion, including significant central hypovolemia and hypotension (including hemorrhage, and during cardiac bypass surgery. This review presents the dichotomous views on the role of hemodynamic variability on clinical outcome, including the physiological mechanisms underlying these patterns, and the potential impact of increased and decreased variability on cerebral perfusion and oxygenation. We suggest that reconciliation of these two apparently discrepant views may lie in the time scale of hemodynamic variability; short time scale variability appears to be cerebroprotective, while mid to longer term fluctuations are associated with primary and secondary end-organ dysfunction.

  14. [Functional assessment of the hepatic arterial blood flow by pharmacoradiography (author's transl)].

    Science.gov (United States)

    Stellamor, K; Hruby, W; Peschl, L

    1981-12-01

    By means of celiacography it was possible to demonstrate that parenteral medication with parathormone creates a selective dilatation of the liver vessels in man, provided that they are dilatable. This hemodynamic hormone effect could not be traced in the other mesenteric vessels. The increase of portal hypertension resulting from cirrhosis leads to a loss of the dilating ability of liver vessels. This regressive reaction is well demonstrated on the parathormon-celiaco-gram. Thus a functional assessment of the hepatic blood flow is possible. The extent of the dilatability of the liver artery seems to be of great importance for the prognosis and indication of the porto-systemic shunt-operation. Moreover we could show that an increase in the liver perfusion demonstrates pathologic liver processes in a better way. PMID:7323629

  15. Amylin: Localization, Effects on Cerebral Arteries and on Local Cerebral Blood Flow in the Cat

    Directory of Open Access Journals (Sweden)

    Lars Edvinsson

    2001-01-01

    Full Text Available Amylin and adrenomedullin are two peptides structurally related to calcitonin gene-related peptide (CGRP. We studied the occurrence of amylin in trigeminal ganglia and cerebral blood vessels of the cat with immunocytochemistry and evaluated the role of amylin and adrenomedullin in the cerebral circulation by in vitro and in vivo pharmacology. Immunocytochemistry revealed that numerous nerve cell bodies in the trigeminal ganglion contained CGRP immunoreactivity (-ir; some of these also expressed amylin-ir but none adrenomedullin-ir. There were numerous nerve fibres surrounding cerebral blood vessels that contained CGRP-ir. Occasional fibres contained amylin-ir while we observed no adrenomedullin-ir in the vessel walls. With RT-PCR and Real-Time�PCR we revealed the presence of mRNA for calcitonin receptor-like receptor (CLRL and receptor-activity-modifying proteins (RAMPs in cat cerebral arteries. In vitro studies revealed that amylin, adrenomedullin, and CGRP relaxed ring segments of the cat middle cerebral artery. CGRP and amylin caused concentration-dependent relaxations at low concentrations of PGF2a-precontracted segment (with or without endothelium whereas only at high concentration did adrenomedullin cause relaxation. CGRP8-37 blocked the CGRP and amylin induced relaxations in a parallel fashion. In vivo studies of amylin, adrenomedullin, and CGRP showed a brisk reproducible increase in local cerebral blood flow as examined using laser Doppler flowmetry applied to the cerebral cortex of the a-chloralose�anesthetized cat. The responses to amylin and CGRP were blocked by CGRP8-37. The studies suggest that there is a functional sub-set of amylin-containing trigeminal neurons which probably act via CGRP receptors.

  16. Effect of selective occlusion of the umbilical arteries and/or veins on uterine blood flow in sheep.

    Science.gov (United States)

    Hasaart, T H; de Haan, J; Horiguchi, T

    1986-01-01

    Maternal uterine blood flow was depressed during total umbilical cord occlusion, probably based on an increased fetal cotyledonary tissue pressure (Hasaart and de Haan (1985) Eur. J. Obstet. Gynec. Reprod. Biol., 19, 125-131). This supposed mechanism was further analysed by performing selective occlusions of the umbilical arteries and/or veins (mean occlusion time 35 s). An occluding device which allowed separate occlusion of umbilical veins and arteries was applied to the umbilical cord in 7 chronically prepared fetal lambs between 106 and 135 days gestation. Median uterine artery blood flow (UBF) was measured with an electromagnetic flow meter. During occlusion of both umbilical veins (VV, n = 22) in 6 animals a maximal decrease in UBF to 87.5% of control value (P less than 0.001) was found at the end occlusion, followed by a gradual return to control value in the post occlusion period. Occlusion of both umbilical arteries (AA, n = 29) in 5 animals was accompanied by a slight increase in UBF to 103% of control value (P less than 0.01). Total occlusion of the umbilical arteries and veins simultaneously (n = 17) in 4 animals did not result in any change in UBF. The changes in volume and turgor in the fetal cotyledonary tissue associated with the arterial and venous occlusions should lead to respectively a decrease (AA) and increase (VV) in resistance to maternal flow, causing the changes in uterine blood flow. It is concluded that volume changes in the fetal compartment of the sheep placenta affect maternal uterine blood flow. PMID:3956829

  17. Examination of nanoparticles as a drug carrier on blood flow through catheterized composite stenosed artery with permeable walls.

    Science.gov (United States)

    Ijaz, S; Nadeem, S

    2016-09-01

    In this paper, we have discussed the influence of copper nanoparticles on a blood flow through composite stenosed artery with permeable walls. The nature of blood is discussed mathematically by considering it as viscous nanofluid. The study is carried out for a blood vessel under mild stenosis approximations and expressions of the temperature, velocity, resistance impedance to flow, wall shear stress and the pressure gradient is obtained by using corresponding boundary conditions. Results for the effects of permeability on blood flow through composite stenosis have been discussed graphically. The considered analysis also summarizes that the drug copper nanoparticles are efficient to reduce hemodynamics of stenosis and could be helpful to predict important uses for biomedical applications. Results indicate that nanoparticles are helpful as drug carriers to minimize the effects of resistance impedance to blood flow or coagulation factors due to stenosis. PMID:27393802

  18. Asymptotic analysis of blood flow in stented arteries: time dependency and direct simulations***

    Directory of Open Access Journals (Sweden)

    Pichon Gostaf Kirill

    2010-12-01

    Full Text Available This work aims to extend in two distinct directions results recently obtained in [10]. In a first step we focus on the possible extension of our results to the time dependent case. Whereas in the second part some preliminary numerical simulations aim to give orders of magnitudes in terms of numerical costs of direct 3D simulations. We consider, in the first part, the time dependent rough problem for a simplified heat equation in a straight channel that mimics the axial velocity under an oscillating pressure gradient. We derive first order approximations with respect to ϵ, the size of the roughness. In order to understand the problem and set up correct boundary layer approximations, we perform a time periodic fourier analysis and check that no frequency can interact with the roughness. We show rigorously on this toy problem that the boundary layers remain stationary in time (independent on the frequency number. Finally we perform numerical tests validating our theoretical approach. In the second part, we determine actual limits, when running three-dimensional blood flow simulations of the non-homogenized stented arteries. We solve the stationary Stokes equations for an artery containing a saccular aneurysm. Consecutive levels of uniform mesh refinement, serve to relate spatial resolution, problem scale, and required computation time. Test computations are presented for femoral side aneurysm, where a simplified ten-wire stent model was placed across the aneurysm throat. We advocate the proposed stent homogenization model, by concluding that an actual computation power is not sufficient to run accurate, direct simulations of a pulsatile flow in stented vessels.

  19. Duplex Color Doppler Evaluation of Retinal Arterial Blood Flow in Type 2 Diabetic Subjects without Retinopathy

    Directory of Open Access Journals (Sweden)

    Mashah Binte Amin

    2014-09-01

    Full Text Available Background: Diabetic retinopathy is a vascular disorder affecting the microvasculature of retina. It is caused by changes in the blood vessels of retina. If untreated, it may lead to blindness which is usually preventable if retinopathy is diagnosed early and treated promptly. In ophthalmology, color Doppler imaging is a new method that enables us to assess the orbital vasculature. It allows for simultaneous two dimensional anatomical and Doppler evaluations of hemodynamic characteristics of retinal artery. Objective: To observe the difference between Doppler flow velocity indices (peak systolic velocity, end diastolic velocity and resistive index of retinal artery in type 2 diabetic subjects without retinopathy and those of normal controls. Materials and Methods: This case-control study was carried out in the department of Radiology and Imaging, Bangladesh Institute of Research and Rehabilitation in Diabetes, Endocrine and Metabolic Disorders (BIRDEM in collaboration with Ophthalmology Outpatient Department, BIRDEM, Dhaka from July 2011 to June 2013. Eighty diabetic patients without retinopathy aged 27–68 years were enrolled as cases and age and sex matched 80 healthy subjects were selected as controls. Type 1 diabetic patients, type 2 diabetics with retinopathy, hypertensive and dyslipidemic subjects were excluded from the study. All the selected subjects underwent duplex Doppler ultrasonography of both eyes using 5 to 7.5 MHZ linear phase transducer. Duplex color Doppler findings including spectral analysis (PSV, EDV and RI were recorded. Unpaired t test was done to compare blood flow velocity indices of retinal artery in type 2 diabetic patients without retinopathy and that of healthy control subjects. p value <0.05 was considered as significant. Results: Majority (42.5% and 47.5% of subjects were in 4th decade of life in both groups with predominance of males. The mean duration of diabetes was 4.56 ± 2.1 years. Mean peak systolic

  20. Effects of unsteadiness and non-Newtonian rheology on blood flow through a tapered time-variant stenotic artery

    Directory of Open Access Journals (Sweden)

    A. Zaman

    2015-03-01

    Full Text Available A two-dimensional model is used to analyze the unsteady pulsatile flow of blood through a tapered artery with stenosis. The rheology of the flowing blood is captured by the constitutive equation of Carreau model. The geometry of the time-variant stenosis has been used to carry out the present analysis. The flow equations are set up under the assumption that the lumen radius is sufficiently smaller than the wavelength of the pulsatile pressure wave. A radial coordinate transformation is employed to immobilize the effect of the vessel wall. The resulting partial differential equations along with the boundary and initial conditions are solved using finite difference method. The dimensionless radial and axial velocity, volumetric flow rate, resistance impedance and wall shear stress are analyzed for normal and diseased artery with particular focus on variation of these quantities with non-Newtonian parameters.

  1. Synthetic reconstruction of dynamic blood flow in cortical arteries using optical coherence tomography for the evaluation of vessel compliance

    Science.gov (United States)

    Baraghis, Edward; Bolduc, Virginie; Gillis, Marc-Antoine; Srinivasan, Vivek J.; Thorin, Éric; Boudoux, Caroline; Lesage, Frédéric

    2011-03-01

    Optical Coherence Tomography (OCT) has recently been used to produce 3D angiography of microvasculature in the rodent brain in-vivo and blood flow maps of large vessels. Key enabling developments were novel algorithms for detecting Doppler shifts produced by moving scatterers and new scanning protocols tailored to increase sensitivity to small flow speeds. These progresses were pushed by the need for a non invasive imaging modality to monitor quantitative blood flow at a higher resolution and a greater depth than could be achieved by other means. The rationale for this work originates from new hypotheses regarding the role of blood regulation in neurodegenerative diseases and from current investigations of animal models of vascular degeneration. In this work we demonstrate the synthetic reconstruction of dynamic blood flow in mice over the course of a single cardiac cycle in an 800μm wide by ~ 3mm deep B-Frame slice with a lateral resolution of 10μm and a depth resolution of 7μm. Images were taken using a cranial window over the exposed parietal bone of mice skull. Electrocardiography (ECG) recordings were co registered with the OCT A lines at high temporal resolution. QRS peak detection was then used to locate the time value of each A-line in the cardiac cycle and to reconstruct a synthetic temporal frame over one cardiac cycle. Doppler speed in this cardiac cycle was used to measure temporal variations of flow inside arteries and of their area. Three dimensional volume scans yielded measurements of quantitative blood flow on the same arteries. Using these informations a measure of compliance could be established. Comparing measures between atherosclerotic (ATX) and wild type (WT) mice revealed higher blood flow in WT mice, suggested lower systemic compliance in the ATX group but higher compliance of cerebral vasculature on these mice. These results are consistent with expectations showing that OCT is a potential tool for in-vivo arterial compliance evaluation.

  2. Regional changes in cerebral blood flow oxygenation can indicate global changes in cerebral blood flow during coronary artery occlusion in juvenile pigs

    International Nuclear Information System (INIS)

    Near infrared spectroscopy (NIRS) is a widely employed method for assessment of regional cerebral oxygenation (RcStO2). RcStO2 values are expected to vary with changes in the relative amount of oxyhaemoglobin. The present experimental study aimed to assess the response of RcStO2 to controlled alterations of carotid blood flow (CQ). Landrace pigs were anesthetized followed by surgical preparation. Cyclic variations in cardiac output were accomplished by intermittently occluding the main stem of the left coronary artery. A flow measurement probe for assessing CQ was placed around the left carotid artery. One NIRS probe was placed on the left ipsilateral forehead to assess regional cerebral oximetry. Simultaneous registration of CQ and RcStO2 was conducted. There was a strong correlation for variation in CQ and RcStO2 signal values. Based on coherence analysis the fraction of power of the RcStO2 that was coherent with the CQ signal reached 0.84 ± 0.12 (P < 0.05) for frequencies lower than 0.1 Hz. The agreement of the sample-to-sample co-variation, as assessed by the Pearson correlation coefficient, was 0.83 ± 0.08 (P < 0.05). One explanatory component for variations in cerebral oxygenation verified by NIRS should be attributed to variations in the cerebral blood flow. (paper)

  3. Blood flow parameters of the superior mesenteric artery as an early predictor of intestinal dysmotility in preterm infants

    Energy Technology Data Exchange (ETDEWEB)

    Robel-Tillig, Eva; Knuepfer, Matthias; Pulzer, Ferdinand; Vogtmann, Christoph [University of Leipzig, Department of Neonatology, Children' s Hospital, Leipzig (Germany)

    2004-12-01

    Blood flow parameters in the superior mesenteric artery (SMA) change with vasoconstriction or vasodilatation of the intestinal vascular bed. In cases of severe growth retardation as a result of haemodynamic disturbances, the blood flow changes persist into postnatal life. To assess early changes of Doppler sonographic blood flow parameters in the SMA for prediction of later intestinal motility disturbances in preterm infants and tolerance of enteral feeding during the first week of life. Doppler sonographic blood flow parameters in the SMA were measured on the first day of life and the following 5 days in 478 neonates with a birth weight below 1,500 g. According to the Doppler results, the neonates were divided into two groups - those with pathological parameters and those with normal blood flow parameters. Correlations between blood flow parameters, the development of intestinal dysmotility and the tolerated amount of enteral feeding were calculated. Pathological blood flow parameters were observed in 148 neonates (group 1) and normal blood flow parameters in 330 neonates (group 2). Intestinal motility disturbance occurred in 125 neonates (83%) of group 1 and 47 neonates (15%) of group 2. Neonates in group 2 tolerated significantly more feed by the fifth day of life than neonates in group 1. Postnatal adaptation did not differ between the two groups, although the majority of neonates with intestinal dysmotility were small for gestational age. The predictive value of blood flow parameters for prediction of intestinal motility revealed high sensitivity and specificity by the first postnatal day, 2 or 3 days before development of clinical signs of intestinal dysmotility. There was a strong negative correlation between pathological pulsatility index on day 1 and the quantity of tolerated enteral feeding on day 5. Pathological blood flow parameters in the SMA can predict problems of intestinal motility and tolerance of enteral feeding. With the early detection of these

  4. Blood flow parameters of the superior mesenteric artery as an early predictor of intestinal dysmotility in preterm infants

    International Nuclear Information System (INIS)

    Blood flow parameters in the superior mesenteric artery (SMA) change with vasoconstriction or vasodilatation of the intestinal vascular bed. In cases of severe growth retardation as a result of haemodynamic disturbances, the blood flow changes persist into postnatal life. To assess early changes of Doppler sonographic blood flow parameters in the SMA for prediction of later intestinal motility disturbances in preterm infants and tolerance of enteral feeding during the first week of life. Doppler sonographic blood flow parameters in the SMA were measured on the first day of life and the following 5 days in 478 neonates with a birth weight below 1,500 g. According to the Doppler results, the neonates were divided into two groups - those with pathological parameters and those with normal blood flow parameters. Correlations between blood flow parameters, the development of intestinal dysmotility and the tolerated amount of enteral feeding were calculated. Pathological blood flow parameters were observed in 148 neonates (group 1) and normal blood flow parameters in 330 neonates (group 2). Intestinal motility disturbance occurred in 125 neonates (83%) of group 1 and 47 neonates (15%) of group 2. Neonates in group 2 tolerated significantly more feed by the fifth day of life than neonates in group 1. Postnatal adaptation did not differ between the two groups, although the majority of neonates with intestinal dysmotility were small for gestational age. The predictive value of blood flow parameters for prediction of intestinal motility revealed high sensitivity and specificity by the first postnatal day, 2 or 3 days before development of clinical signs of intestinal dysmotility. There was a strong negative correlation between pathological pulsatility index on day 1 and the quantity of tolerated enteral feeding on day 5. Pathological blood flow parameters in the SMA can predict problems of intestinal motility and tolerance of enteral feeding. With the early detection of these

  5. The effect of phenylephrine on arterial and venous cerebral blood flow in healthy subjects

    DEFF Research Database (Denmark)

    Ogoh, Shigehiko; Sato, Kohei; Fisher, James P;

    2011-01-01

    Sympathetic regulation of the cerebral circulation remains controversial. Although intravenous phenylephrine (PE) infusion reduces the near-infrared spectroscopy (NIRS)-determined measure of frontal lobe oxygenation (S(c) O(2) ) and increases middle cerebral artery mean blood velocity (MCA V...

  6. Cerebral small-resistance artery structure and cerebral blood flow in normotensive subjects and hypertensive patients

    Energy Technology Data Exchange (ETDEWEB)

    De Ciuceis, Carolina; Porteri, Enzo; Rizzoni, Damiano; Boari, Gianluca E.M.; Rosei, Enrico Agabiti [University of Brescia, Clinica Medica, Department of Clinical and Experimental Sciences, Brescia (Italy); Cornali, Claudio; Mardighian, Dikran; Fontanella, Marco M. [University of Brescia, Section of Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); Pinardi, Chiara [Spedali Civili, Medical Physics Unit, Brescia (Italy); University of Brescia, Section of Neuroradiology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); Rodella, Luigi F.; Rezzani, Rita [University of Brescia, Section of Anatomy, Department of Clinical and Experimental Sciences, Brescia (Italy); Gasparotti, Roberto [University of Brescia, Section of Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); University of Brescia, Section of Neuroradiology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy)

    2014-12-15

    The aim of this study was to prospectively investigate whether the structure of cerebral small-resistance arteries is related to cerebral perfusion parameters as measured with dynamic susceptibility-weighted contrast magnetic resonance imaging (DSC-MRI) in a selected cohort of hypertensive and normotensive patients. Ten hypertensive and 10 normotensive patients were included in the study. All patients underwent neurosurgical intervention for an intracranial tumor and were investigated with DSC-MRI at 1.5 T. Cerebral small-resistance arteries were dissected from a small portion of morphologically normal cerebral tissue and mounted on an isometric myograph for the measurement of the media-to-lumen (M/L) ratio. A quantitative assessment of cerebral blood flow (CBF) and volume (CBV) was performed with a region-of-interest approach. Correlation coefficients were calculated for normally distributed variables. The institutional review board approved the study, and informed consent was obtained from all patients. Compared with normotensive subjects, hypertensive patients had significantly lower regional CBF (mL/100 g/min) in the cortical grey matter (55.63 ± 1.90 vs 58.37 ± 2.19, p < 0.05), basal ganglia (53.34 ± 4.39 vs 58.22. ± 4.33, p < 0.05), thalami (50.65 ± 3.23 vs 57.56 ± 4.45, p < 0.01), subcortical white matter (19.32 ± 2.54 vs 22.24 ± 1.9, p < 0.05), greater M/L ratio (0.099 ± 0.013 vs 0.085 ± 0.012, p < 0.05), and lower microvessel density (1.66 ± 0.67 vs 2.52 ± 1.28, p < 0.05). A statistically significant negative correlation was observed between M/L ratio of cerebral arteries and CBF in the cortical grey matter (r = -0.516, p < 0.05), basal ganglia (r = -0.521, p < 0.05), thalami (r = -0.527 p < 0.05), and subcortical white matter (r = -0.612, p < 0.01). Our results indicate that microvascular structure might play a role in controlling CBF, with possible clinical consequences. (orig.)

  7. Changes of arterial blood flow patterns by patients' posture during hepatic arterial infusion chemotherapy assessed by 99mTc-MAA perfusion scintigraphy

    International Nuclear Information System (INIS)

    Hepatic arterial perfusion scintigraphy (HAPS) with 99mTc-macroaggregated albumin (MAA) was performed to reveal the effect of patients' posture for the arterial blood flow patterns in hepatic arterial infusion (HAI) chemotherapy. Twenty patients with liver metastases having the percutaneously implanted catheter into the hepatic artery underwent HAPS following administration of 99mTc-MAA at the supine and the upright position under one week interval. Ten ml of the saline with radionuclide was injected at a rate of one ml per minute. Acquired two images at the different position of each patient were compared and grouped into three classes: similar, slightly different and different. Of 20 patients, 6 (30%) were judged as similar, 8 (40%) as slightly different, and 6 (30%) as different. These results suggest that the drug distribution can change by patients' posture in case of the slow rate HAI performed with continuous infusion pump. (author)

  8. Outflow boundary conditions for 3D simulations of non-periodic blood flow and pressure fields in deformable arteries

    CERN Document Server

    Vignon-Clementel, Irene; Jansen, K E; Taylor, C A; 10.1080/10255840903413565

    2010-01-01

    The simulation of blood flow and pressure in arteries requires outflow boundary conditions that incorporate models of downstream domains. We previously described a coupled multidomain method to couple analytical models of the downstream domains with 3D numerical models of the upstream vasculature. This prior work either included pure resistance boundary conditions or impedance boundary conditions based on assumed periodicity of the solution. However, flow and pressure in arteries are not necessarily periodic in time due to heart rate variability, respiration, complex transitional flow or acute physiological changes. We present herein an approach for prescribing lumped parameter outflow boundary conditions that accommodate transient phenomena. We have applied this method to compute haemodynamic quantities in different physiologically relevant cardiovascular models, including patient-specific examples, to study non-periodic flow phenomena often observed in normal subjects and in patients with acquired or congen...

  9. Validation of an optical flow algorithm to measure blood flow waveforms in arteries using dynamic digital x-ray images

    Science.gov (United States)

    Rhode, Kawal; Lambrou, Tryphon; Hawkes, David J.; Hamilton, George; Seifalian, Alexander M.

    2000-06-01

    We have developed a weighted optical flow algorithm for the extraction of instantaneous blood velocity from dynamic digital x-ray images of blood vessels. We have carried out in- vitro validation of this technique. A pulsatile physiological blood flow circuit was constructed using sections of silicone tubing to simulate blood vessels with whole blood as the fluid. Instantaneous recording of flow from an electromagnetic flow meter (EMF) provided the gold standard measurement. Biplanar dynamic digital x-ray images of the blood vessel with injection of contrast medium were acquired at 25 fps using a PC frame capture card. Imaging of a Perspex calibration cube allowed 3D reconstruction of the vessel and determination of true dimensions. Blood flow waveforms were calculated off-line on a Sun workstation using the new algorithm. The correlation coefficient between instantaneous blood flow values obtained from the EMF and the x-ray method was r equals 0.871, n equals 1184, p less than 0.0001. The correlation coefficient for average blood flow was r equals 0.898, n equals 16, p less than 0.001. We have successfully demonstrated that our new algorithm can measure pulsatile blood flow in a vessel phantom. We aim to use this algorithm to measure blood flow clinically in patients undergoing vascular interventional procedures.

  10. MR velocity mapping measurement of renal artery blood flow in patients with impaired kidney function

    DEFF Research Database (Denmark)

    Cortsen, M; Petersen, L.J.; Stahlberg, F;

    1996-01-01

    . MR velocity mapping was performed in both renal arteries using an ECG-triggered gradient echo pulse sequence previously validated in normal volunteers. Effective renal plasma flow was calculated from the clearance rate of PAH during constant infusion and the split of renal function was evaluated by...

  11. Suspension model for blood flow through a catheterized arterial stenosis with peripheral layer of plasma free from cells

    Science.gov (United States)

    Ponalagusamy, R.

    2016-06-01

    The present article describes the blood flow in a catheterized artery with radially symmetric and axially asymmetric stenosis. To understand the effects of red cell concentration, plasma layer thickness and catheter size simultaneously, blood is considered by a two-layered model comprising a core region of suspension of all the erythrocytes (particles) supposed to be a particle-fluid mixture and a peripheral zone of cell-free plasma. The analytical expressions for flow features, such as fluid phase and particle phase velocities, flow rate, wall shear stress and resistive force are obtained. It is witnessed that the presence of the catheter causes a substantial increase in the frictional forces on the walls of arterial stenosis and catheter, shear stress and flow resistance, in addition to that, have occurred due to the presence of red cells concentration (volume fraction density of the particles) and the absence of peripheral plasma layer near the wall of the stenosed artery. The introduction of an axially asymmetric nature of stenosis and plasma layer thickness causes significant reduction in flow resistance. One can notice that the two-phase fluid (suspension model) is more profound to the thickness of peripheral plasma layer and catheter than the single-phase fluid.

  12. Improving Cerebral Blood Flow Quantification for Arterial Spin Labeled Perfusion MRI by Removing Residual Motion Artifacts and Global Signal Fluctuations

    OpenAIRE

    Wang, Ze

    2012-01-01

    Denoising is critical to improving the quality and stability of cerebral blood flow (CBF) quantification in arterial spin labeled (ASL) perfusion MRI due to the intrinsic low signal-to-noise-ratio (SNR) of ASL data. Previous studies have been focused on reducing the spatial or temporal noise using standard filtering techniques, and less attention has been paid to two global nuisance effects, the residual motion artifacts and the global signal fluctuations. Since both nuisances affect the whol...

  13. The effect of intra-arterial endothelin on resting blood flow and sympathetically mediated vasoconstriction in the forearm of man.

    OpenAIRE

    Cockcroft, J R; Clarke, J G; Webb, D. J.

    1991-01-01

    1. The hypothesis that endothelin (ET) influences sympathetically mediated vasoconstriction was investigated in 13 healthy, male subjects. 2. ET (1 pmol min-1) was infused for 60 min into the left brachial arteries of seven healthy male subjects. Resting forearm blood flow, and sympathetic vasoconstriction produced by lower body negative pressure (LBNP; 15 mm Hg), was measured in both arms by strain gauge plethysmography. In a further six subjects, noradrenaline (NA) was infused intra-arteria...

  14. A lumped-parameter model to investigate the effect of plantar pressure on arterial blood flow in a diabetic foot.

    Science.gov (United States)

    Hahn, C; Mahajan, A; Chu, T; Schoen, M

    2007-08-01

    This paper presents a lumped-parameter model for the big-toe region that investigates the effect of plantar pressure on the diameter of the blood vessels, specifically the arteries, in the presence of arterial and/or tissue changes. The model developed in this paper uses a multi-domain energy system approach to develop the lumped-parameter differential equations. Blood flow is modelled as fluidic flow through compliant pipes that have inertia, stiffness, and damping. The tissue material is treated as a soft compliant material that transmits the external force to the blood vessels. Conclusions have been drawn to show the effect of plantar pressure, tissue damage, and their combination on the diameter of the blood vessels. The principles used here can be used to model the entire foot and the model used to investigate the effect of plantar pressure, tissue damage, and arterial changes on different parts of the foot. The work presented here may also have applications in other vascular diseases. PMID:17937206

  15. Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

    Science.gov (United States)

    Gewirtz, Henry; Dilsizian, Vasken

    2016-05-31

    In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted. PMID:27245647

  16. Contribution of spiral artery blood flow changes assessed by transvaginal color Doppler sonography for predicting endometrial pathologies

    Directory of Open Access Journals (Sweden)

    Suna Kabil Kucur

    2013-01-01

    Full Text Available ive: To investigate the diagnostic value of blood flow measurements in spiral artery by transvaginal color Doppler sonography (CDS in predicting endometrial pathologies.Methods: Ninety-seven patients presenting with abnormal uterine bleeding and requiring endometrial assessment were included in this prospective observational study. Endometrial thickness, structure and echogenicity were recorded. Pulsatility index (PI and resistive index (RI of the spiral artery were measured by transvaginal CDS. Endometrial sampling was performed for all subjects. Sonographic and hystopathologic findings were compared.Results: The histopathological diagnoses were as follows; 39 cases (40.2% endometrial polyp, 9 cases (9.3% endometrial hyperplasia, 10 cases (10.3 submucous myoma, 7 cases (7.2% endometrium cancer, and 32 cases (33% nonspecific findings. The spiral artery PI in endometrium cancer group was highly significantly lower than other groups (p<0.01. The spiral artery RI was also significantly lower in the patients with malignant histology (p<0.05. Conclusion: Endometrial pathologies are associated significantly with endometrial spiral artery Doppler changes.Key words: Spiral artery, Doppler ultrasonography, endometrium

  17. Magnetic resonance imaging-based computational modelling of blood flow and nanomedicine deposition in patients with peripheral arterial disease.

    Science.gov (United States)

    Hossain, Shaolie S; Zhang, Yongjie; Fu, Xiaoyi; Brunner, Gerd; Singh, Jaykrishna; Hughes, Thomas J R; Shah, Dipan; Decuzzi, Paolo

    2015-05-01

    Peripheral arterial disease (PAD) is generally attributed to the progressive vascular accumulation of lipoproteins and circulating monocytes in the vessel walls leading to the formation of atherosclerotic plaques. This is known to be regulated by the local vascular geometry, haemodynamics and biophysical conditions. Here, an isogeometric analysis framework is proposed to analyse the blood flow and vascular deposition of circulating nanoparticles (NPs) into the superficial femoral artery (SFA) of a PAD patient. The local geometry of the blood vessel and the haemodynamic conditions are derived from magnetic resonance imaging (MRI), performed at baseline and at 24 months post intervention. A dramatic improvement in blood flow dynamics is observed post intervention. A 500% increase in peak flow rate is measured in vivo as a consequence of luminal enlargement. Furthermore, blood flow simulations reveal a 32% drop in the mean oscillatory shear index, indicating reduced disturbed flow post intervention. The same patient information (vascular geometry and blood flow) is used to predict in silico in a simulation of the vascular deposition of systemically injected nanomedicines. NPs, targeted to inflammatory vascular molecules including VCAM-1, E-selectin and ICAM-1, are predicted to preferentially accumulate near the stenosis in the baseline configuration, with VCAM-1 providing the highest accumulation (approx. 1.33 and 1.50 times higher concentration than that of ICAM-1 and E-selectin, respectively). Such selective deposition of NPs within the stenosis could be effectively used for the detection and treatment of plaques forming in the SFA. The presented MRI-based computational protocol can be used to analyse data from clinical trials to explore possible correlations between haemodynamics and disease progression in PAD patients, and potentially predict disease occurrence as well as the outcome of an intervention. PMID:25878124

  18. Changes in central retinal artery blood flow after ocular warming and cooling in healthy subjects

    Directory of Open Access Journals (Sweden)

    Shamshad M

    2010-01-01

    Full Text Available Context: Retinal perfusion variability impacts ocular disease and physiology. Aim: To evaluate the response of central retinal artery (CRA blood flow to temperature alterations in 20 healthy volunteers. Setting and Design: Non-interventional experimental human study. Materials and Methods: Baseline data recorded: Ocular surface temperature (OST in °C (thermo-anemometer, CRA peak systolic velocity (PSV and end diastolic velocity (EDV in cm/s using Color Doppler. Ocular laterality and temperature alteration (warming by electric lamp/cooling by ice-gel pack were randomly assigned. Primary outcomes recorded were: OST and intraocular pressure (IOP immediately after warming or cooling and ten minutes later; CRA-PSV and EDV at three, six and nine minutes warming or cooling. Statistical Analysis: Repeated measures ANOVA. Results: (n = 20; μ±SD: Pre-warming values were; OST: 34.5±1.02°C, CRA-PSV: 9.3±2.33cm/s, CRA-EDV: 4.6±1.27cm/s. OST significantly increased by 1.96°C (95% CI: 1.54 to 2.37 after warming, but returned to baseline ten minutes later. Only at three minutes, the PSV significantly rose by 1.21cm/s (95% CI: 0.51to1.91. Pre-cooling values were: OST: 34.5±0.96°C, CRA-PSV: 9.7±2.45 cm/s, CRA-EDV: 4.7±1.12cm/s. OST significantly decreased by 2.81°C (95% CI: -2.30 to -3.37 after cooling, and returned to baseline at ten minutes. There was a significant drop in CRA-PSV by 1.10cm/s (95% CI: -2.05 to -0.15 and CRA-EDV by 0.81 (95% CI: -1.47 to -0.14 at three minutes. At six minutes both PSV (95% CI: -1.38 to -0.03 and EDV (95% CI: -1.26 to -0.02 were significantly lower. All values at ten minutes were comparable to baseline. The IOP showed insignificant alteration on warming (95% CI of difference: -0.17 to 1.57mmHg, but was significantly lower after cooling (95% CI: -2.95 to -4.30mmHg. After ten minutes, IOP had returned to baseline. Conclusion : This study confirms that CRA flow significantly increases on warming and decreases on cooling

  19. An efficient approach to study the pulsatile blood flow in femoral and coronary arteries by Differential Quadrature Method

    Science.gov (United States)

    Ghasemi, Seiyed E.; Hatami, M.; Hatami, J.; Sahebi, S. A. R.; Ganji, D. D.

    2016-02-01

    In this paper, flow analysis for a non-Newtonian third grade blood in coronary and femoral arteries is simulated numerically. Blood is considered as the third grade non-Newtonian fluid under periodic body acceleration motion and pulsatile pressure gradient. Differential Quadrature Method (DQM) and Crank Nicholson Method (CNM) are used to solve the Partial Differential Equation (PDE) governing equation by which a good agreement between them was observed in the results. The influences of some physical parameters such as amplitude, lead angle and body acceleration frequency on non-dimensional velocity and profiles are considered. For instance, the results show that increasing the amplitude, Ag, and reducing the lead angle of body acceleration, ϕ, make higher velocity profiles in the center line of both arteries.

  20. The Effects of Nitric Oxide Donors on Uterine Artery and Sub-endometrial Blood Flow in Patients with Unexplained Recurrent Abortion

    OpenAIRE

    Abdel-Razik, Mohamed; El-Berry, Seham; Mostafa, Ahmed

    2014-01-01

    Background Nitric oxide plays a major role in increasing uterine blood flow during the luteal phase and early pregnancy. This study was done to compare uterine artery and sub-endometrial blood flow indices during the luteal phase between patients with unexplained recurrent abortion and fertile women and also to evaluate the effects of nitric oxide donors on blood flow indices in the abortion group. Methods The study included a control group of 30 primiparae who had normal vaginal delivery and...

  1. Numerical and Analytical Study of Two-Layered Unsteady Blood Flow through Catheterized Artery.

    Science.gov (United States)

    Zaman, Akbar; Ali, Nasir; Sajid, M; Hayat, Tasawar

    2016-01-01

    The pulsatile flow of blood in a catheterized blood vessel is analyzed. The flow of blood in vessel is modeled as the flow of two immiscible fluids. The fluid in the core region is characterized as a non-Newtonian viscoelastic fluid satisfying the constitutive equation of an Oldroyd-B fluid. The fluid in the peripheral region is treated as a Newtonian fluid. The catheter inside the vessel is modeled as a rigid tube of very small radius. The resulting differential system for velocity in each region is computed numerically by finite-difference scheme and analytically by Laplace transform. A comparison of numerical solution with Laplace transform solution is carried out. Various physical quantities of interest through the computed velocity are also analyzed. PMID:27548476

  2. COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM

    Directory of Open Access Journals (Sweden)

    H. GIRIJA BAI

    2012-12-01

    Full Text Available The aim of this study is a numerical simulation of hemodynamics in blood vessels with multiple fusiform aneurysms. Dilation of 0.25 is considered. Using computational fluid dynamics, hemodynamic factors such as velocity and pressure are investigated. The problem is solved by finite volume method. Numerical simulation is prescribed using the CFD softwares Fluent and Gambit. High pressure and low velocity is observed in the region of aneurysm. This is an indication to the interruption of blood flow. These techniques based on computer flow study are important for understanding the relationship between hemodynamic parameters and risk of rupture.

  3. Reduced peripheral arterial blood flow with preserved cardiac output during submaximal bicycle exercise in elderly heart failure

    Directory of Open Access Journals (Sweden)

    Leng Xiaoyan

    2009-11-01

    Full Text Available Abstract Background Older heart failure (HF patients exhibit exercise intolerance during activities of daily living. We hypothesized that reduced lower extremity blood flow (LBF due to reduced forward cardiac output would contribute to submaximal exercise intolerance in older HF patients. Methods and Results Twelve HF patients both with preserved and reduced left ventricular ejection fraction (LVEF (aged 68 ± 10 years without large (aorta or medium sized (iliac or femoral artery vessel atherosclerosis, and 13 age and gender matched healthy volunteers underwent a sophisticated battery of assessments including a peak exercise oxygen consumption (peak VO2, b physical function, c cardiovascular magnetic resonance (CMR submaximal exercise measures of aortic and femoral arterial blood flow, and d determination of thigh muscle area. Peak VO2 was reduced in HF subjects (14 ± 3 ml/kg/min compared to healthy elderly subjects (20 ± 6 ml/kg/min (p = 0.01. Four-meter walk speed was 1.35 ± 0.24 m/sec in healthy elderly verses 0.98 ± 0.15 m/sec in HF subjects (p p ≤ 0.03. Conclusion During CMR submaximal bike exercise in the elderly with heart failure, mechanisms other than low cardiac output are responsible for reduced lower extremity blood flow.

  4. Evaluation of the Effects of Sildenafil Citrate (Viagra) on Vertebral Artery Blood Flow in Patients with Vertebro-Basilar Insufficiency

    Energy Technology Data Exchange (ETDEWEB)

    Bozgeyik, Zulkif; Berilgen, Sait; Ozdemir, Huseyin; Ogur, Erkin [Firat University School of Medicine, Elazig(Turkmenistan); Tekatas, Aslan [Elazig Government Hospital, Elazig (Turkmenistan)

    2008-12-15

    To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). The study included 21 patients with VBI (aged 31-76; mean 61.0 +- 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm{sup 2} to 10.80 cm{sup 2} at 45 minutes and 10.81 cm{sup 2} at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs

  5. Evaluation of the Effects of Sildenafil Citrate (Viagra) on Vertebral Artery Blood Flow in Patients with Vertebro-Basilar Insufficiency

    International Nuclear Information System (INIS)

    To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). The study included 21 patients with VBI (aged 31-76; mean 61.0 ± 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm2 to 10.80 cm2 at 45 minutes and 10.81 cm2 at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs

  6. Synergy between shear-induced migration and secondary flows on red blood cells transport in arteries: considerations on oxygen transport.

    Science.gov (United States)

    Biasetti, Jacopo; Spazzini, Pier Giorgio; Hedin, Ulf; Gasser, T Christian

    2014-08-01

    Shear-induced migration of red blood cells (RBCs) is a well-known phenomenon characterizing blood flow in the small vessels (micrometre to millimetre size) of the cardiovascular system. In large vessels, like the abdominal aorta and the carotid artery (millimetre to centimetre size), the extent of this migration and its interaction with secondary flows has not been fully elucidated. RBC migration exerts its influence primarily on platelet concentration, oxygen transport and oxygen availability at the luminal surface, which could influence vessel wall disease processes in and adjacent to the intima. Phillips' shear-induced particle migration model, coupled to the Quemada viscosity model, was employed to simulate the macroscopic behaviour of RBCs in four patient-specific geometries: a normal abdominal aorta, an abdominal aortic aneurysm (AAA), a normal carotid bifurcation and a stenotic carotid bifurcation. Simulations show a migration of RBCs from the near-wall region with a lowering of wall haematocrit (volume fraction of RBCs) on the posterior side of the normal aorta and on the lateral-external side of the iliac arteries. A marked migration is observed on the outer wall of the carotid sinus, along the common carotid artery and in the carotid stenosis. No significant migration is observed in the AAA. The spatial and temporal patterns of wall haematocrit are correlated with the near-wall shear layer and with the secondary flows induced by the vessel curvature. In particular, secondary flows accentuate the initial lowering in RBC near-wall concentration by convecting RBCs from the inner curvature side to the outer curvature side. The results reinforce data in literature showing a decrease in oxygen partial pressure on the inner curvature wall of the carotid sinus induced by the presence of secondary flows. The lowering of wall haematocrit is postulated to induce a decrease in oxygen availability at the luminal surface through a diminished concentration of

  7. NUMERICAL ANALYSIS OF THE NON-NEWTONIAN BLOOD FLOW IN THE NON-PLANAR ARTERY WITH BIFURCATION

    Institute of Scientific and Technical Information of China (English)

    CHEN Jie; LU Xi-yun; ZHUANG Li-xian; WANG Wen

    2004-01-01

    A numerical analysis of non-Newtonian fluid flow in non-planar artery with bifurcation was performed by using a finite element method to solve the three-dimensional Navier-Stokes equations coupled with the non-Newtonian constitutive models, including Carreau,Cross and Bingham models. The objective of this study is to investigate the effects of the non-Newtonian properties of blood as well as curvature and out-of-plane geometry in the non-planar daughter vessels on the velocity distribution and wall shear stress. The results of this study support the view that the non-planarity of blood vessels and the non-Newtonian properties of blood are of important in hemodynamics and play a significant role in vascular biology and pathophysiology.

  8. Computational Dynamics of Arterial Blood Flow in the Presence of Magnetic Field and Thermal Radiation Therapy

    Directory of Open Access Journals (Sweden)

    T. Chinyoka

    2014-01-01

    Full Text Available We conduct a numerical study to determine the influence of magnetic field and thermal radiation on both velocity and temperature distributions in a single blood vessel. The model here assumes that blood is a Newtonian incompressible conducting fluid with radially varying viscosity due to hematocrit variation. The transient equations of momentum and energy transport governing the flow in an axisymmetric configuration are solved numerically using a semi-implicit finite difference method. Results are presented graphically and discussed both qualitatively and quantitatively from the physiological point of view. The results of this work may enhance current understanding of the factors that determine the effects of hyperthermia treatment on tumor tissues.

  9. Features of cerebral blood flow, cardiac arrhythmias and conduction disturbances in patients with essential hypertension stage II associated with occlusive and stenotic lesions of brachiocephalic arteries

    Directory of Open Access Journals (Sweden)

    Vizir V.A.

    2015-09-01

    Full Text Available Arterial hypertension is the most common disease of the cardiovascular system in industrially advanced countries. With the aim to determine the characteristics of cerebral blood flow, disorders of cardiac rhythm and conduction in patients with stage 2 hypertension associated with stenotic and occlusive lesions of brachiocephalic arteries, cerebral blood flow indicators were studied in 87 patients using duplex scanning of extracranial arteries and Holter ECG monitoring. It was established that linear blood flow velocity was considerably decreased in the basins of the internal and common carotid artery; cerebral blood flow asymmetry was present in the course of the internal carotid artery. Evidence-based differences in structure of arrhythmias were revealed by single and paired ventricular extrasystoles, as well as episodes of unstable ventricular tachycardia. All this indicates the progressive decrease of elasticity and tonicity of vessel walls, intensified rigidity and sinuosity of carotid arteries, more severe disorders of cardiac rhythm and conduction in case of simultaneous hypertension and atherosclerotic lesion of brachiocephalic arteries.

  10. Analysis of Flow Characteristics of the Blood Flowing through an Inclined Tapered Porous Artery with Mild Stenosis under the Influence of an Inclined Magnetic Field

    Directory of Open Access Journals (Sweden)

    Neetu Srivastava

    2014-01-01

    Full Text Available Analytical investigation of MHD blood flow in a porous inclined stenotic artery under the influence of the inclined magnetic field has been done. Blood is considered as an electrically conducting Newtonian fluid. The physics of the problem is described by the usual MHD equations along with appropriate boundary conditions. The flow governing equations are finally transformed to nonhomogeneous second-order ordinary differential equations. This model is consistent with the principles of magnetohydrodynamics. Analytical expressions for the velocity profile, volumetric flow rate, wall shear stress, and pressure gradient have been derived. Blood flow characteristics are computed for a specific set of values of the different parameters involved in the model analysis and are presented graphically. Some of the obtained results show that the flow patterns in converging region (ξ0, and nontapered region (ξ=0 are effectively influenced by the presence of magnetic field and change in inclination of artery as well as magnetic field. There is also a significant effect of permeability on the wall shear stress as well as volumetric flow rate.

  11. Analysis of Flow Characteristics of the Blood Flowing through an Inclined Tapered Porous Artery with Mild Stenosis under the Influence of an Inclined Magnetic Field.

    Science.gov (United States)

    Srivastava, Neetu

    2014-01-01

    Analytical investigation of MHD blood flow in a porous inclined stenotic artery under the influence of the inclined magnetic field has been done. Blood is considered as an electrically conducting Newtonian fluid. The physics of the problem is described by the usual MHD equations along with appropriate boundary conditions. The flow governing equations are finally transformed to nonhomogeneous second-order ordinary differential equations. This model is consistent with the principles of magnetohydrodynamics. Analytical expressions for the velocity profile, volumetric flow rate, wall shear stress, and pressure gradient have been derived. Blood flow characteristics are computed for a specific set of values of the different parameters involved in the model analysis and are presented graphically. Some of the obtained results show that the flow patterns in converging region (ξ 0), and nontapered region (ξ = 0) are effectively influenced by the presence of magnetic field and change in inclination of artery as well as magnetic field. There is also a significant effect of permeability on the wall shear stress as well as volumetric flow rate. PMID:24719614

  12. Muscle size and arterial stiffness after blood flow-restricted low-intensity resistance training in older adults.

    Science.gov (United States)

    Yasuda, T; Fukumura, K; Fukuda, T; Uchida, Y; Iida, H; Meguro, M; Sato, Y; Yamasoba, T; Nakajima, T

    2014-10-01

    Previous studies have shown that blood flow-restricted low-intensity resistance training (BFR-RT) causes muscle hypertrophy while maintaining arterial function in young adults. We examined the effects of BFR-RT on muscle size and arterial stiffness in older adults. Healthy subjects (ages 61-84 years) were divided into BFR-RT (n = 9) or non-training control (CON; n = 10) groups. The BFR-RT group performed 20% and 30%, respectively, of one-repetition maximal (1-RM) knee extension and leg press exercises, 2 days/wk for 12 weeks. The BFR-RT group wore elastic cuffs (120-270 mmHg) on both legs during training. Magnetic resonance imaging-measured muscle cross-sectional area (CSA), 1-RM strength, chair stand (CS) test, and cardio-ankle vascular index testing (CAVI), an index of arterial stiffness, were measured before and 3-5 days after the final training session. Muscle CSA of the quadriceps (8.0%), adductors (6.5%), and gluteus maximus (4.4%), leg extension and leg press 1-RM strength (26.1% and 33.4%), and CS performance (18.3%) improved (P testing, there were no changes in both two groups. In conclusion, BFR-RT improves muscle CSA as well as maximal muscle strength, but does not negatively affect arterial stiffness or humeral coagulation factors in older adults. PMID:23730848

  13. Pulsatile Non-Newtonian Laminar Blood Flows through Arterial Double Stenoses

    OpenAIRE

    Mir Golam Rabby; Sumaia Parveen Shupti; Md. Mamun Molla

    2014-01-01

    The paper presents a numerical investigation of non-Newtonian modeling effects on unsteady periodic flows in a two-dimensional (2D) pipe with two idealized stenoses of 75% and 50% degrees, respectively. The governing Navier-Stokes equations have been modified using the Cartesian curvilinear coordinates to handle complex geometries. The investigation has been carried out to characterize four different non-Newtonian constitutive equations of blood, namely, the (i) Carreau, (ii) Cross, (iii) Mod...

  14. The phosphodiesterase 3 inhibitor cilostazol dilates large cerebral arteries in humans without affecting regional cerebral blood flow

    DEFF Research Database (Denmark)

    Birk, Steffen; Kruuse, Christina Rostrup; Petersen, Kenneth A;

    2004-01-01

    the middle cerebral arteries (VMCA) was measured with transcranial Doppler, and the superficial temporal and radial arteries diameters were measured with ultrasonography. During the 4-hour observation period, there was no effect on systolic blood pressure (P = 0.28), but diastolic blood pressure...

  15. Modeling of the blood flow in the lower extremities for dynamic diffuse optical tomography of peripheral artery disease

    Science.gov (United States)

    Marone, A.; Hoi, J. W.; Khalil, M. A.; Kim, H. K.; Shrikhande, G.; Dayal, R.; Hielscher, A. H.

    2015-07-01

    Peripheral Arterial Disease (PAD) is caused by a reduction of the internal diameters of the arteries in the upper or lower extremities mainly due to atherosclerosis. If not treated, its worsening may led to a complete occlusion, causing the death of the cells lacking proper blood supply, followed by gangrene that may require chirurgical amputation. We have recently performed a clinical study in which good sensitivities and specificities were achieved with dynamic diffuse optical tomography. To gain a better understanding of the physiological foundations of many of the observed effects, we started to develop a mathematical model for PAD. The model presented in this work is based on a multi-compartment Windkessel model, where the vasculature in the leg and foot is represented by resistors and capacitors, the blood pressure with a voltage drop, and the blood flow with a current. Unlike existing models, the dynamics induced by a thigh-pressure-cuff inflation and deflation during the measurements are taken into consideration. This is achieved by dynamically varying the resistances of the large veins and arteries. By including the effects of the thigh-pressure cuff, we were able to explain many of the effects observed during our dynamic DOT measurements, including the hemodynamics of oxy- and deoxy-hemoglobin concentration changes. The model was implemented in MATLAB and the simulations were normalized and compared with the blood perfusion obtained from healthy, PAD and diabetic patients. Our preliminary results show that in unhealthy patients the total system resistance is sensibly higher than in healthy patients.

  16. Study on blood flow containing nanoparticles through porous arteries in presence of magnetic field using analytical methods

    Science.gov (United States)

    Ghasemi, Seiyed E.; Hatami, M.; Sarokolaie, A. Kalani; Ganji, D. D.

    2015-06-01

    In this paper, flow analysis for a third grade non-Newtonian blood in porous arteries in presence of magnetic field is simulated analytically and numerically. Blood is considered as the third grade non-Newtonian fluid containing nanoparticles. Collocation Method (CM) and Optimal Homotopy Asymptotic Method (OHAM) are used to solve the Partial Differential Equation (PDE) governing equation which a good agreement between them was observed in the results. The influences of the some physical parameters such as Brownian motion parameter, pressure gradient and thermophoresis parameter, etc. on temperature, velocity and nanoparticles concentration profiles are considered. For instance, increasing the thermophoresis parameter (Nt) caused an increase in temperature values in whole domain and an increase in nanoparticles concentration near the inner wall.

  17. Continuous blood gas monitoring in femoral arteries

    Science.gov (United States)

    Schlain, Les A.; Spar, Steven M.; Dellinger, Bart

    1995-05-01

    Continuous intra-arterial blood gas monitoring is a potentially valuable tool in the surgical and intensive care arenas. Patient oxygenation and acid base status can change rapidly and without warning. The ability to monitor pHa, PaCO2 and PaO2 in arterial blood will be a major medical advance for the anesthesiologist and intensivist. Intra-arterial blood gas sensors are typically placed in radial arteries. In certain patient populations accurate monitoring is not possible in radial arteries due to arterial environmental factors such as hypotension, vasoconstriction and atherosclerotic disease. These same factors can make radial cannulation difficult resulting in traumatic catheter insertion, thereby further compromising flow conditions. In situations where radial artery flow is expected to be compromised, selecting a large vessel for sensor placement is desirable. We report an initial feasibility study of our blood gas monitoring system using the femoral artery as the sensing site. Clinical results are presented as well as potential advantages and disadvantages associated with monitoring in the femoral artery.

  18. C-14-activity incorporation into the protein of fetal organs of guinea pigs with different maternal placental blood flow and fetal arterial O2-saturation

    International Nuclear Information System (INIS)

    In anaesthesised gravid guinea-pigs the dilate, end section of a placental radial artery was connected to the A.carotis via a flow meter and a throttle in order to measure and widely alter the maternal placental blood flow. Blood samples are taken from the fetal A.carotis, the fetal arterial O2-saturation and the Hb-content were determined. By altering the maternal placental blood circulation the fetal arterial O2-concentration can stabilised at various levels. In order to study the protein synthesis, under these conditions one infused 185 kBq C-14-leucine over a period of 3 hours into the jugular vein of the fetus. During infusion the radioactive concentrations in whole plasma and plasma water were measured. After the infusion the radioactive concentrations in the tissue fluid, the intracellular fluid and the acid-insoluble tissue fraction (protein) of the heart, kidenys, liver, the muscles of the upper end lower part of the body, the brain and the placenta were measured. The following deductions were drawn from the findings: The maternal placental blood flow vitally influences the activity incorporation per activity concentration in the plasma water. These findings agree with the hypotheses that the maternal blood circulation has an essential influence on the fetal proteins synthesis and that this influence can be attributed to the connection between placenta connection blood flow and oxygen saturation of fetal arterial blood. (orig.)

  19. Quantitative measurement of regional myocardial blood flow in patients with coronary artery disease by intravenous injection of 13N-ammonia in positron emission tomography

    International Nuclear Information System (INIS)

    Measurement of myocardial blood flow with 13N-ammonia, a technique previously employed successfully in animal experiments, was introduced into clinical use to study patients with coronary artery disease. This advance has become possible by the development of a high resolution gated scan positron emission tomographic (PET) scanner equipped with a real time decay correction mechanism, HEADTOME-IV. The information obtainable includes myocardial size and wall motion as well as the absolute quantity of blood flow in various myocardial regions. The technique is simple but requires continuous arterial blood withdrawal for calculation of the arterial input function time integral. The alternative to this technique, i.e. the computation of intra left ventricular blood pool activity by PET is also discussed. (orig.)

  20. Middle cerebral artery blood velocity during running

    DEFF Research Database (Denmark)

    Lyngeraa, Tobias; Pedersen, Lars Møller; Mantoni, T;

    2013-01-01

    Running induces characteristic fluctuations in blood pressure (BP) of unknown consequence for organ blood flow. We hypothesized that running-induced BP oscillations are transferred to the cerebral vasculature. In 15 healthy volunteers, transcranial Doppler-determined middle cerebral artery (MCA...

  1. Different Bleeding Patterns with the Use of Levonorgestrel Intrauterine System: Are They Associated with Changes in Uterine Artery Blood Flow?

    Directory of Open Access Journals (Sweden)

    Carlo Bastianelli

    2014-01-01

    Full Text Available Objective. Evaluate if different bleeding patterns associated with the use of the levonorgestrel intrauterine system (LNG-IUS are associated with different uterine and endometrial vascularization patterns, as evidenced by ultrasound power Doppler analysis. Methodology. A longitudinal study, with each subject acting as its own control was conducted between January 2010 and December 2012. Healthy volunteers with a history of heavy but cyclic and regular menstrual cycles were enrolled in the study. Ultrasonographic examination was performed before and after six months of LNG-IUS placement: uterine volume, endometrial thickness, and subendometrial and myometrial Doppler blood flow patterns have been evaluated. Results. A total of 32 women were enrolled out of 186 initially screened. At six months of follow-up, all subjects showed a reduction in menstrual blood loss; for analysis, they were retrospectively divided into 3 groups: normal cycling women (Group I, amenorrheic women (Group II, and women with prolonged bleedings (Group III. Intergroup analysis documented a statistically significant difference in endometrial thickness among the three groups; in addition, mean pulsatility index (PI and resistance index (RI in the spiral arteries were significantly lower in Group I and Group III compared to Group II. This difference persisted also when comparing—within subjects of Group III—mean PI and RI mean values before and after insertion. Conclusions. The LNG-IUS not only altered endometrial thickness, but—in women with prolonged bleedings—also significantly changed uterine artery blood flow. Further studies are needed to confirm these results and enable gynecologists to properly counsel women, improving initial continuation rates.

  2. Cerebral blood flow volume measurements of the carotid artery and ipsilateral branches using two-dimensional phase-contrast magnetic resonance angiography

    Institute of Scientific and Technical Information of China (English)

    Gang Guo; Yonggui Yang; Weiqun Yang

    2011-01-01

    The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encodingwas set to 80 cm/s. Results of the measurements showed that the error rate was 7.0 ± 6.0%in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateralcommon carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. Inaddition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore,after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accuratein the determination of BFV in the carotid arteries.

  3. Xenon CT measurements of intrahepatic blood flow divided from portal veins and arteries in healthy control and patients with chronic hepatitis and liver cirrhosis

    International Nuclear Information System (INIS)

    Using Xenon computed tomography (Xe-CT), we measured intrahepatic blood flow volume divided from portal veins and arteries in 6 healthy volunteers (HV), 22 patients with biopsy-proven chronic hepatitis (CH), and 16 patients with pathologically or clinically diagnosed as liver cirrhosis (LC). Intrahepatic blood flow volume on computed CT image were indicated of color scale and calculated by each region of interest (ROI) in reliability map. Portal veins blood flows in the liver lobes decreased with progression of chronic liver disease such as 68±7 (HV), 46±18 (CH), 37±12 (LC) ml/min/100 g in the right liver lobe, and 71±9 (HV), 45±19 (CH), 35±15 (LC) ml/min/100 g in the left liver lobe, respectively. Arterial blood flow measured by Xe-CT in the left liver lobe increased with Child-Pugh classification and portal blood flow in the liver lobes decreased with Child-Pugh classification in patients with LC. Our results suggest Xe-CT is expected as the non-invasive and easy method for evaluating intrahepatic blood flow divided from portal veins and arteries in patients with chronic liver diseases. (author)

  4. Acute effect of oral sensation of sweetness on celiac artery blood flow and gastric myoelectrical activity in humans.

    Science.gov (United States)

    Eguchi, Kohei; Kashima, Hideaki; Yokota, Akiko; Miura, Kohei; Yamaoka Endo, Masako; Hirano, Harutoyo; Tsuji, Toshio; Fukuba, Yoshiyuki

    2016-05-01

    Little is known about the effect of sweet taste stimulus on gastrointestinal motility and splanchnic blood flow. We examined whether gastric myoelectrical activity and/or celiac artery blood flow (CABF), which perfuses the stomach, are increased following an oral sensation of sweetness. After overnight fasting, 11 subjects rested for 5min and sipped, but not swallowed, one of four solutions for 1min. The fluid was then spat out, and subjects remained at rest for a further 10min. Fluids were approximately 15ml of three glucose solutions (4, 16, or 48%) or distilled water. Subjects completed trials with all four solutions in a randomized order. During each trial, gastric myoelectrical activity and CABF were continuously measured using electrogastrography and pulsed Doppler ultrasonography, respectively. None of the four solutions affected gastric myoelectrical activity. CABF was significantly increased after oral stimuli by all three glucose solutions, but not by water. There were no significant differences in the increments in CABF among the three glucose solutions. These results suggest that a sweet taste stimulus above a certain level of intensity acutely increases CABF during cephalic phase, without augmentation of gastric myoelectrical activity. PMID:26987409

  5. Simultaneous mapping of temporally-resolved blood flow velocity and oxygenation in femoral artery and vein during reactive hyperemia

    Directory of Open Access Journals (Sweden)

    Langham Michael C

    2011-10-01

    Full Text Available Abstract Background Post-occlusive hyperemia is often used as a paradigm to evaluate vascular reactivity, for example by measuring post-ischemic flow-mediated dilation, arterial blood flow or temporally resolved venous blood oxygenation (HbO2. Here we demonstrate the feasibility of a simultaneous measurement of blood flow and HbO2 in the femoral circulation as part of a single procedure. Methods A multi-echo GRE pulse sequence was designed and implemented to collect velocity-encoded projections in addition to full-image echoes for field mapping as a means to quantify intravascular magnetic susceptibility. The method's feasibility was evaluated at 3T in a small pilot study involving two groups of healthy subjects (mean ages 26 ± 1.6 and 59 ± 7.3 years, N = 7 and 5, respectively in terms of six parameters characterizing the time-course of reactive hyperemia and their sensitivity to differentiate age effects. The reproducibility was assessed on two of the seven young healthy subjects with three repeated measurements. Results The physiological parameters agree with those obtained with current methods that quantify either velocity or HbO2 alone. Of the six measures of vascular reactivity, one from each group was significantly different in the two subject groups (p Conclusion The proposed method is able quantify multiple parameters that may lead to more detailed assessment of peripheral vascular reactivity in a single cuff paradigm rather than in separate procedures as required previously, thereby improving measurement efficiency and patient comfort.

  6. Relaxin mediates uterine artery compliance during pregnancy and increases uterine blood flow

    OpenAIRE

    Vodstrcil, Lenka A.; Tare, Marianne; Novak, Jacqueline; Dragomir, Nicoleta; Ramirez, Rolando J.; Wlodek, Mary E.; Conrad, Kirk P.; Parry, Laura J.

    2012-01-01

    Normal pregnancy involves dramatic remodeling of the uterine vasculature, with abnormal vascular adaptations contributing to pregnancy diseases such as preeclampsia. The peptide hormone relaxin is important for the renal and systemic hemodynamic adaptations to pregnancy, and has been shown to increase arterial compliance and outward hypertrophic remodeling. Therefore, we investigated the possibility that relaxin acts on its receptor, RXFP1, to mediate uterine artery compliance in late pregnan...

  7. Changes of Umbilical Artery Blood Flow Due to Pregnancy Induced Hypertension in the Third Trimester of Pregnancy

    Directory of Open Access Journals (Sweden)

    Sarah Hashemi

    2010-05-01

    Full Text Available Background/Objective: Doppler ultrasound of umbilical vessels is a method of evaluating fetoplacental blood flow which is very important in high risk pregnancies including pregnancy induced hypertension and may predict both the duration of maternal hospitalization and fetal mortality rates in IUGR. In this study, Doppler indices of blood flow through the umbilical artery were measured in patients with pregnancy induced hypertension."nPatients and Methods: This study was a cross-sectional study which was carried out on 101 preg-nant women: 35 patients with pregnancy induced hypertension were in the case group that had no symptoms or signs of pre-eclampsia, eclampsia or diabetes melitus. 61 normal pregnant women were as the control group. All the patients were studied in their third trimester of pregnancy. Doppler ultrasound of the umbilical artery was performed for both the case and the control groups. Peak Systolic Velocity (PSV, End Diastolic Velocity (EDV and mean velocity were measured. The Resistive Index (RI, Pulsatility Index (PI and Systolic to diastolic ratio (S/D ratio were calculated. The statistical analysis was performed on the obtained recorded data, using SPSS software."nResults: The calculated mean values of spectral Doppler indices in the case group were: 0.77 for RI; 1.39 for PI and 4.88 for S/D ratio while in the control group they were calculated as 0.64, 1.08 and 2.97, respectively. Altogether, comparison of the mean values of the mentioned indices revealed a significant difference between the two groups (P<0.01. The case group was significantly rated higher in terms of the above mentioned indices."nConclusion: In patients with pregnancy induced hypertension without any complications (such as pre-eclampsia or eclampsia or without any other risk factors (such as diabetes mellitus and IUGR, Doppler ultrasound should be used for evaluating the degree of fetoplacental blood flow in order to decrease the risk of pregnancy

  8. Distinct alterations in sublingual microcirculatory blood flow and hemoglobin oxygenation in on-pump and off-pump coronary artery bypass graft surgery

    NARCIS (Netherlands)

    B. Atasever; C. Boer; P. Goedhart; J. Biervliet; J. Seyffert; R. Speekenbrink; L. Schwarte; B. de Mol; C. Ince

    2011-01-01

    The authors hypothesized that cardiopulmonary bypass (CPB) (on-pump) is associated with more severe changes in the microcirculatory blood flow and tissue oxygenation as compared with off-pump coronary artery bypass surgery. An observational study. A university hospital and teaching hospital. Patient

  9. Segmental abnormal perfusion in the liver: Relation between hepatic arterial and portal vein blood flow in the fast contrast CT

    International Nuclear Information System (INIS)

    Sixty seven cases of segmental arterial hyperperfusion and thirty one cases of segmental portal hypoperfusion detected among 803 cases of arterial and portal dominant CT were studied for the evaluation of etiology and mechanism casuing intrahepatic segmental abnormal perfusion in normal portion of the liver around hepatic mass. Hepatic masses casuing segmental abnormal perfusion were hepatocellular carcinoma, peripheral cholangiocarcinoma, metastasis, abscess, and cavernous hemangioma. Segmental portal hypoperfusion was seen on the area of segmental arterial hyperperfusion in all the cases and segmental arterial hyperperfusion was seen on the area of segmental portal hypoperfusion in 77% of cases. In conclusion, there are intrahepatic segmental portal and arterial abnormal perfusions in normal portion around hepatic mass, and these phenomena may be developed with close reciprocal alteration between both portal and hepatic arterial flows

  10. In-vitro validation of a novel model-based approach to the measurement of arterial blood flow waveforms from dynamic digital x-ray images

    Science.gov (United States)

    Rhode, Kawal; Lambrou, Tryphon; Seifalian, Alexander M.; Hawkes, David J.

    2002-04-01

    We have developed a waveform shape model-based algorithm for the extraction of blood flow from dynamic arterial x-ray angiographic images. We have carried out in-vitro validation of this technique. A pulsatile physiological blood flow circuit was constructed using an anthropomorphic cerebral vascular phantom to simulate the cerebral arterial circulation with whole blood as the fluid. Instantaneous recording of flow from an electromagnetic flow meter (EMF) provided the gold standard measurement. Biplane dynamic digital x-ray images of the vascular phantom with injection of contrast medium were acquired at 25 fps using a PC frame capture card with calibration using a Perspex cube. Principal component analysis was used to construct a shape model by collecting 434 flow waveforms from the EMF under varying flow conditions. Blood flow waveforms were calculated from the angiographic data by using our previous concentration-distance curve matching (ORG) algorithm and by using the new model-based (MB) algorithm. Both instantaneous and mean flow values calculated using the MB algorithm showed greater correlation, less bias, and lower variability than those calculated using the ORG algorithm when compared to the EMF values. We have successfully demonstrated that use of a priori waveform shape information can improve flow measurements from dynamic x-ray angiograms.

  11. Measurement of cerebral blood flow the blood sampling method using {sup 99m}Tc-ECD. Simultaneous scintigram scanning of arterial blood samples and the brain with a gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Hachiya, Takenori; Inugami, Atsushi [Rehabilitation Center for Physically Disabled Persons and Medical Center for Mental Health-Akita, Kyowa (Japan); Iida, Hidehiro; Mizuta, Yoshihiko; Kawakami, Takeshi; Inoue, Minoru

    1999-01-01

    To measure regional cerebral blood flow (rCBF) by blood sampling using {sup 99m}Tc-ECD we devised a method of measuring the radioactive concentration in arterial blood sample with a gamma camera. In this method the head and a blood sample are placed within the same visual field to record the SPECT data of both specimens simultaneously. The results of an evaluation of the counting rate performance, applying the 30 hours decaying method using {sup 99m}Tc solution showed that this method is not comparable to the well-type scintillation counter and in clinical cases the active concentration in arterial blood sample remained well within the dynamic range. In addition, examination of the influence of scattered radiation from the brain by the dilution method showed that it was negligible at a distance of more than 7.5 cm between the brain and the arterial blood sample. In the present study we placed a head-shaped phantom next to the sample. The results of the examinations suggested that this method is suitable for clinical application, and because it does not require a well-type scintillation counter, it is expected to find wide application. (author)

  12. Plasmodium falciparum parasitaemia in the first half of pregnancy, uterine and umbilical artery blood flow, and foetal growth: a longitudinal Doppler ultrasound study

    Directory of Open Access Journals (Sweden)

    Griffin Jennifer B

    2012-09-01

    Full Text Available Abstract Background During early pregnancy, the placenta develops to meet the metabolic demands of the foetus. The objective of this analysis was to examine the effect of malaria parasitaemia prior to 20 weeks’ gestation on subsequent changes in uterine and umbilical artery blood flow and intrauterine growth restriction. Methods Data were analysed from 548 antenatal visits after 20 weeks’ gestation of 128 women, which included foetal biometric measures and interrogation of uterine and umbilical artery blood flow. Linear mixed effect models estimated the effect of early pregnancy malaria parasitaemia on uterine and umbilical artery resistance indices. Log-binomial models with generalized estimating equations estimated the effect of early pregnancy malaria parasitaemia on the risk of intrauterine growth restriction. Results There were differential effects of early pregnancy malaria parasitaemia on uterine artery resistance by nutritional status, with decreased uterine artery resistance among nourished women with early pregnancy malaria and increased uterine artery resistance among undernourished women with early pregnancy malaria. Among primigravidae, early pregnancy malaria parasitaemia decreased umbilical artery resistance in the late third trimester, likely reflecting adaptive villous angiogenesis. In fully adjusted models, primigravidae with early pregnancy malaria parasitaemia had 3.6 times the risk of subsequent intrauterine growth restriction (95% CI: 2.1, 6.2 compared to the referent group of multigravidae with no early pregnancy malaria parasitaemia. Conclusions Early pregnancy malaria parasitaemia affects uterine and umbilical artery blood flow, possibly due to alterations in placentation and angiogenesis, respectively. Among primigravidae, early pregnancy malaria parasitaemia increases the risk of intrauterine growth restriction. The findings support the initiation of malaria parasitaemia prevention and control efforts earlier in

  13. Changes in celebral blood flow induced by balloon test occlusion of the internal carotid artery under hypotension

    International Nuclear Information System (INIS)

    Balloon test occlusion (BTO) of the internal carotid artery (ICA) combined with cerebral blood flow (CBF) study has proved to be a sensitive test for prediction of the outcome of permanent vessel occlusion. In this study, we evaluated the acute changes in regional CBF during BTO under hypotension in order to examine the possible risk of cerebral ischaemia after surgical treatment. Eleven patients in whom surgical carotid sacrifice was planned underwent BTO combined with CBF studies using technetium-99m hexamethyl-propylene amine oxime single-photon emission tomography under hypotension by decreasing the systematic blood pressure by about 50 mm Hg using a ganglion blocking agent. All patients showed a mild to severe decrease in CBF in the ipsilateral ICA territory relative to the contralateral side. A decrease in CBF of greater than 20% was observed in nine patients (82%), and two of them showed a decrease exceeding 40%. However, no ischaemic symptoms were demonstrated during scanning with hypotensive BTO. Our results suggest that in many patients with negative normotensive BTO, a considerable reduction in CBF would occur during hypotension. This procedure may predict a possible risk of hypotensive accident during and/or after surgery. (orig.)

  14. Flow of a biomagnetic viscoelastic fluid: application to estimation of blood flow in arteries during electromagnetic hyperthermia,a therapeutic procedure for cancer treatment

    Institute of Scientific and Technical Information of China (English)

    J.C.MISRA; A.SINHA; G.C.SHIT

    2010-01-01

    The paper deals with the theoretical investigation of a fundamental problem of biomagnetic fluid flow through a porous medium subject to a magnetic field by using the principles of biomagnetic fluid dynamics(BFD).The study pertains to a situation where magnetization of the fluid varies with temperature.The fluid is considered to be non-Newtonian,whose flow is governed by the equation of a second-grade viscoelastic fluid.The walls of the channel are assumed to be stretchable,where the surface velocity is proportional to the longitudinal distance from the origin of coordinates.The problem is first reduced to solving a system of coupled nonlinear differential equations involving seven parameters.Considering blood as a biomagnetic fluid and using the present analysis,an attempt is made to compute some parameters of the blood flow by developing a suitable numerical method and by devising an appropriate finite difference scheme.The computational results are presented in graphical form,and thereby some theoretical predictions are made with respect to the hemodynamical flow of the blood in a hyperthermal state under the action of a magnetic field.The results clearly indicate that the presence of a magnetic dipole bears the potential so as to affect the characteristics of the blood flow in arteries to a significant extent during the therapeutic procedure of electromagnetic hyperthermia.The study will attract the attention of clinicians,to whom the results would be useful in the treatment of cancer patients by the method of electromagnetic hyperthermia.

  15. The Cerebral Blood Flow Biomedical Informatics Research Network (CBFBIRN) database and analysis pipeline for arterial spin labeling MRI data.

    Science.gov (United States)

    Shin, David D; Ozyurt, I Burak; Liu, Thomas T

    2013-01-01

    Arterial spin labeling (ASL) is a magnetic resonance imaging technique that provides a non-invasive and quantitative measure of cerebral blood flow (CBF). After more than a decade of active research, ASL is now emerging as a robust and reliable CBF measurement technique with increased availability and ease of use. There is a growing number of research and clinical sites using ASL for neuroscience research and clinical care. In this paper, we present an online CBF Database and Analysis Pipeline, collectively called the Cerebral Blood Flow Biomedical Informatics Research Network (CBFBIRN) that allows researchers to upload and share ASL and clinical data. In addition to serving the role as a central data repository, the CBFBIRN provides a streamlined data processing infrastructure for CBF quantification and group analysis, which has the potential to accelerate the discovery of new scientific and clinical knowledge. All capabilities and features built into the CBFBIRN are accessed online using a web browser through a secure login. In this work, we begin with a general description of the CBFBIRN system data model and its architecture, then devote the remainder of the paper to the CBFBIRN capabilities. The latter part of our work is divided into two processing modules: (1) Data Upload and CBF Quantification Module; (2) Group Analysis Module that supports three types of analysis commonly used in neuroscience research. To date, the CBFBIRN hosts CBF maps and associated clinical data from more than 1,300 individual subjects. The data have been contributed by more than 20 different research studies, investigating the effect of various conditions on CBF including Alzheimer's, schizophrenia, bipolar disorder, depression, traumatic brain injury, HIV, caffeine usage, and methamphetamine abuse. Several example results, generated by the CBFBIRN processing modules, are presented. We conclude with the lessons learned during implementation and deployment of the CBFBIRN and our

  16. SU-D-18C-05: Variable Bolus Arterial Spin Labeling MRI for Accurate Cerebral Blood Flow and Arterial Transit Time Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, M; Jung, Y [Wake Forest School of Medicine, Winston-Salem, NC (United States)

    2014-06-01

    Purpose: Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition with variable post-labeling delays (PLD) and variable TRs allows for arterial transit time (ATT) mapping and leads to more accurate CBF quantification with a scan time saving of 48%. In addition, T1 and M0 maps can be obtained without a separate scan. In order to accurately estimate ATT and T1 of brain tissue from the ASL data, variable labeling durations were invented, entitled variable-bolus ASL. Methods: All images were collected on a healthy subject with a 3T Siemens Skyra scanner. Variable-bolus Psuedo-continuous ASL (PCASL) images were collected with 7 TI times ranging 100-4300ms in increments of 700ms with TR ranging 1000-5200ms. All boluses were 1600ms when the TI allowed, otherwise the bolus duration was 100ms shorter than the TI. All TI times were interleaved to reduce sensitivity to motion. Voxel-wise T1 and M0 maps were estimated using a linear least squares fitting routine from the average singal from each TI time. Then pairwise subtraction of each label/control pair and averaging for each TI time was performed. CBF and ATT maps were created using the standard model by Buxton et al. with a nonlinear fitting routine using the T1 tissue map. Results: CBF maps insensitive to ATT were produced along with ATT maps. Both maps show patterns and averages consistent with literature. The T1 map also shows typical T1 contrast. Conclusion: It has been demonstrated that variablebolus ASL produces CBF maps free from the errors due to ATT and tissue T1 variations and provides M0, T1, and ATT maps which have potential utility. This is accomplished with a single scan in a feasible scan time (under 6 minutes) with low sensivity to motion.

  17. SU-D-18C-05: Variable Bolus Arterial Spin Labeling MRI for Accurate Cerebral Blood Flow and Arterial Transit Time Mapping

    International Nuclear Information System (INIS)

    Purpose: Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition with variable post-labeling delays (PLD) and variable TRs allows for arterial transit time (ATT) mapping and leads to more accurate CBF quantification with a scan time saving of 48%. In addition, T1 and M0 maps can be obtained without a separate scan. In order to accurately estimate ATT and T1 of brain tissue from the ASL data, variable labeling durations were invented, entitled variable-bolus ASL. Methods: All images were collected on a healthy subject with a 3T Siemens Skyra scanner. Variable-bolus Psuedo-continuous ASL (PCASL) images were collected with 7 TI times ranging 100-4300ms in increments of 700ms with TR ranging 1000-5200ms. All boluses were 1600ms when the TI allowed, otherwise the bolus duration was 100ms shorter than the TI. All TI times were interleaved to reduce sensitivity to motion. Voxel-wise T1 and M0 maps were estimated using a linear least squares fitting routine from the average singal from each TI time. Then pairwise subtraction of each label/control pair and averaging for each TI time was performed. CBF and ATT maps were created using the standard model by Buxton et al. with a nonlinear fitting routine using the T1 tissue map. Results: CBF maps insensitive to ATT were produced along with ATT maps. Both maps show patterns and averages consistent with literature. The T1 map also shows typical T1 contrast. Conclusion: It has been demonstrated that variablebolus ASL produces CBF maps free from the errors due to ATT and tissue T1 variations and provides M0, T1, and ATT maps which have potential utility. This is accomplished with a single scan in a feasible scan time (under 6 minutes) with low sensivity to motion

  18. Computer simulations of blood flow with mass transport through the carotid artery bifurcation

    Directory of Open Access Journals (Sweden)

    Filipović Nenad D.

    2004-01-01

    Full Text Available The current paradigm for clinical diagnostic for the treatment of vascular disease relies exclusively on diagnostic imaging data to define the present state of the patient, empirical data to evaluate the efficacy of prior treatments for similar patients. These techniques are insufficient to predict the outcome of a given treatment for an individual patient. We here propose a new paradigm of predictive medicine where physician could use computational simulation to construct and evaluate a specific geometrical/anatomical model to predict the outcome for an individual patient. For this purpose it is necessary to develop a complex software system which combines user friendly interface, automatic solid modeling, automatic finite mesh generation, computational fluid dynamics and post-processing visualization. The flow dynamics is defined according to the incompressible Navier-Stokes equations for Newtonian and non-Newtonian fluids. Mass transport of oxygen and macromolecules is modeled by the convection diffusion equation and coupled with flow dynamics. The computer simulations are based upon finite element analysis where the new computer methods for coupling oxygen transport and fluid flow are described. The comparison results shows a good agreement between clinical observation for critical zones of flow separation, flow recirculation, low wall shear stresses which may contribute to the development of atherosclerotic diseases.

  19. Caffeine impairs myocardial blood flow response to physical exercise in patients with coronary artery disease as well as in age-matched controls

    OpenAIRE

    Namdar, M; Schepis, T; Koepfli, P; Gaemperli, O; Siegrist, P T; Grathwohl, R; Valenta, I; R. Delaloye; Klainguti, M; Wyss, C A; Lüscher, T F; Kaufmann, P A

    2009-01-01

    BACKGROUND: Caffeine is one of the most widely consumed pharmacologically active substances. Its acute effect on myocardial blood flow is widely unknown. Our aim was to assess the acute effect of caffeine in a dose corresponding to two cups of coffee on myocardial blood flow (MBF) in coronary artery disease (CAD). METHODOLOGY/PRINCIPAL FINDINGS: MBF was measured with (15)O-labelled H2O and Positron Emission Tomography (PET) at rest and after supine bicycle exercise in controls (n = 15, mean a...

  20. Caffeine Impairs Myocardial Blood Flow Response to Physical Exercise in Patients with Coronary Artery Disease as well as in Age-Matched Controls

    OpenAIRE

    Mehdi Namdar; Tiziano Schepis; Pascal Koepfli; Oliver Gaemperli; Siegrist, Patrick T.; Renate Grathwohl; Ines Valenta; Raphael Delaloye; Michael Klainguti; Wyss, Christophe A.; Lüscher, Thomas F.; Kaufmann, Philipp A.

    2009-01-01

    BACKGROUND: Caffeine is one of the most widely consumed pharmacologically active substances. Its acute effect on myocardial blood flow is widely unknown. Our aim was to assess the acute effect of caffeine in a dose corresponding to two cups of coffee on myocardial blood flow (MBF) in coronary artery disease (CAD). METHODOLOGY/PRINCIPAL FINDINGS: MBF was measured with (15)O-labelled H2O and Positron Emission Tomography (PET) at rest and after supine bicycle exercise in controls (n = 15, mean a...

  1. Improving cerebral blood flow quantification for arterial spin labeled perfusion MRI by removing residual motion artifacts and global signal fluctuations.

    Science.gov (United States)

    Wang, Ze

    2012-12-01

    Denoising is critical to improving the quality and stability of cerebral blood flow (CBF) quantification in arterial spin labeled (ASL) perfusion magnetic resonance imaging (MRI) due to the intrinsic low signal-to-noise-ratio (SNR) of ASL data. Previous studies have been focused on reducing the spatial or temporal noise using standard filtering techniques, and less attention has been paid to two global nuisance effects, the residual motion artifacts and the global signal fluctuations. Since both nuisances affect the whole brain, removing them in advance should enhance the CBF quantification quality for ASL MRI. The purpose of this paper was to assess this potential benefit. Three methods were proposed to suppress each or both of the two global nuisances. Their performances for CBF quantification were validated using ASL data acquired from 13 subjects. Evaluation results showed that covarying out both global nuisances significantly improved temporal SNR and test-retest stability of CBF measurement. Although the concept of removing both nuisances is not technically novel per se, this paper clearly showed the benefits for ASL CBF quantification. Dissemination of the proposed methods in a free ASL data processing toolbox should be of interest to a broad range of ASL users. PMID:22789842

  2. Statistical mapping of effects of middle cerebral artery occlusion (MCAO) on blood flow and oxygen consumption in porcine brain.

    Science.gov (United States)

    Watanabe, Hideaki; Sakoh, Masaharu; Andersen, Flemming; Rodell, Anders; Sørensen, Jens Christian; Østergaard, Leif; Mouridsen, Kim; Cumming, Paul

    2007-02-15

    The volume of cerebral tissue perturbed in experimental models of middle cerebral artery occlusion (MCAO) can be highly variable. Thus, the territories of reduced cerebral blood flow (CBF) or oxygen consumption (CMRO(2)) following MCAO might properly be defined using statistical parametric mapping within a population. In order to establish such a method, we mapped CBF and CMRO(2) in 18 pigs with acute MCAO. Parametric maps were flipped about the axis of symmetry, and CBF and CMRO(2) in the infarcted hemisphere were calculated as percentages of the magnitudes in mirror-image pixels. There were log-linear relationships between the volumes of affected tissue and the percentages of normal CFB or CMRO(2). This graphical analysis showed that the volume of the core deficit was smaller for CBF that for CMRO(2), but expanded more rapidly with decreasing CBF deficit than did the corresponding volumes of reduced CMRO(2). Thus, acute changes in CBF and CMRO(2) following MCAO in the pig can be defined as probabilistic volumes. PMID:17129609

  3. Color Doppler analysis of uterine, spiral, and intraovarian artery blood flow before and after treatment with cabergoline in hyperprolactinemic patients.

    Science.gov (United States)

    Temizkan, Osman; Temizkan, Sule; Asicioglu, Osman; Aydin, Kadriye; Kucur, Suna

    2015-01-01

    Prolactin (PRL) may have stimulatory effects on vascular resistance. We aimed to analyze uterine, spiral, and intraovarian artery blood flow by Doppler ultrasonography in hyperprolactinemic patients prior to and after treatment with cabergoline. The study was conducted in Sisli Etfal Training and Research Hospital gynecology outpatient clinic between 1 March 2010 and 30 September 2011. Twenty-four women with symptomatic hyperprolactinemia in reproduction age were included in the study. All hyperprolactinemic patients were studied prior to and following the suppression of circulating PRL levels by cabergoline. Patients were examined by standard B-mod and color transvaginal ultrasonography. Pulsality index (PI), resistance index (RI), and systolic/diastolic ratio (S/D) were recorded. The median PRL value was 86 (62-120) ng/ml before treatment and 4.0 (2.5-6.4) ng/ml after the treatment (p cabergoline treatment. In conclusion, this is a pilot study which shows for the first time that PRL increases the uterine, endometrial, and intraovarian vascular resistance and cabergoline reverses this effect. PMID:25222841

  4. Reconciling paradigms of abnormal pulmonary blood flow and quasi-malignant cellular alterations in pulmonary arterial hypertension.

    Science.gov (United States)

    Happé, C M; Szulcek, R; Voelkel, N F; Bogaard, H J

    2016-08-01

    In pulmonary arterial hypertension (PAH) structural and functional abnormalities of the small lung vessels interact and lead to a progressive increase in pulmonary vascular resistance and right heart failure. A current pathobiological concept characterizes PAH as a 'quasi-malignant' disease focusing on cancer-like alterations in endothelial cells (EC) and the importance of their acquired apoptosis-resistant, hyper-proliferative phenotype in the process of vascular remodeling. While changes in pulmonary blood flow (PBF) have been long-since recognized and linked to the development of PAH, little is known about a possible relationship between an altered PBF and the quasi-malignant cell phenotype in the pulmonary vascular wall. This review summarizes recognized and hypothetical effects of an abnormal PBF on the pulmonary vascular bed and links these to quasi-malignant changes found in the pulmonary endothelium. Here we describe that abnormal PBF does not only trigger a pulmonary vascular cell growth program, but may also maintain the cancer-like phenotype of the endothelium. Consequently, normalization of PBF and EC response to abnormal PBF may represent a treatment strategy in patients with established PAH. PMID:26804008

  5. Predicting extraction and uptake of arterial energy metabolites by the mammary glands of lactating cows when blood flow is perturbed.

    Science.gov (United States)

    Cant, J P; Madsen, T G; Cieslar, S R L

    2016-01-01

    Previous work shows that mammary uptake of milk precursors from blood can be affected by the rate of blood flow (F) to the glands. The purpose of the current work was to test the ability of compartmental and cylindrical capillary models to account for the variation in mammary extraction and net uptake of plasma metabolites produced by perturbation of mammary F. The data for model fitting were obtained from a previous experiment in which mammary arteriovenous differences of acetate + β-hydroxybutyrate (2C), glucose, triacylglycerol (TAG), and long-chain fatty acids (LCFA) were measured in 4 cows before, during, and after intraarterial infusion of inhibitors of endothelial nitric oxide synthase and cyclooxygenase, which are 2 major systems of F control in the mammary glands. The 4 models tested were (1) constant extraction within each cow, (2) clearance from an extracellular compartment is a linear function of F with an intercept, (3) total capillary volume in a cylindrical representation is a linear function of F with an intercept, and (4) uptake from an extracellular compartment obeys Henri-Michaelis-Menten kinetics, where maximum velocity (Vmax) is a linear function of F with an intercept. According to prediction errors, model 4 fitted 2C extraction data best, accounting for 82% of the observed variation. The estimated Km (Henri-Michaelis-Menten constant) for venous 2C was 0.4 mM. For glucose clearance, a variant of model 2 with a positive effect of 2C uptake on clearance was identified as best, producing a coefficient of determination (R(2)) of 0.31. For TAG, model 2 with a positive effect of arterial TAG concentration on TAG clearance was best, with an R(2) of 0.22. For LCFA, model 2 with a positive effect of arterial LCFA on LCFA clearance was best, with an R(2) of 0.29. Models 2 and 3 fitted the extraction data with the same R(2)-values and prediction errors, so both compartmental and cylindrical approaches to describing the vascular bed were equally capable

  6. Renal Arteriovenous Fistula with Rapid Blood Flow Successfully Treated by Transcatheter Arterial Embolization: Application of Interlocking Detachable Coil as Coil Anchor

    International Nuclear Information System (INIS)

    A 70-year-old woman presented to our outpatient clinic with a large idiopathic renal arteriovenous fistula (AVF). Transcatheter arterial embolization (TAE) using interlocking detachable coils (IDC) as an anchor was planned. However, because of markedly rapid blood flow and excessive coil flexibility, detaching an IDC carried a high risk of migration. Therefore, we first coiled multiple loops of a microcatheter and then loaded it with an IDC. In this way, the coil was well fitted to the arterial wall and could be detached by withdrawing the microcatheter during balloon occlusion ('pre-framing technique'). Complete occlusion of the afferent artery was achieved by additional coiling and absolute ethanol. This technique contributed to a safe embolization of a high-flow AVF, avoiding migration of the IDC

  7. Comparison of myocardial blood flow induced by adenosine triphosphate and dipyridamole in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Myocardial perfusion imaging with adenosine triphosphate (ATP) has been used increasingly to diagnose coronary artery disease (CAD) and assess risk for this disease. This study compared absolute myocardial blood flow (MBF) and myocardial flow reserve index (MFR) with ATP and dipyridamole (DIP) in patients with CAD. MBF was quantified by 15O-H2O PET in 21 patients with CAD (17 male, 4 female), aged 55 to 81 years. MBF was measured at rest, during intravenous injection of ATP (0.16 mg/kg/min), and again after DIP infusion (0.56 mg/kg). Regions of interest were drawn in nonischemic and ischemic segments based on findings from thallium-201 (201Tl) scintigraphy and coronary angiography (CAG). Absolute MBF values and indexes of MFR were calculated in nonischemic and ischemic segments. Intravenous injection of ATP and DIP significantly increased MBF in nonischemic (2.4±0.9 and 2.1±0.8 ml/g/min, respectively; p<0.01, for both) and in ischemic segments (1.3±0.4 and 1.5±0.4 ml/g/min, respectively; p<0.01, for both). There was a significant difference in MBF values between ATP and DIP in nonischemic segments (p<0.05), which was not observed in ischemic segments. In nonischemic segments, ATP produced higher MFR than DIP (2.1±0.8 and 1.8±0.7, respectively; p<0.05), while no significant difference was observed in ischemic segments (1.5±0.6 and 1.7±0.3, respectively). ATP produced a greater hyperemia than DIP between the ischemic and nonischemic myocardium in patients with CAD. ATP is as effective as DIP for the diagnosis of CAD. (author)

  8. Effects of Restoration of Blood Flow on the Development of Aortic Atherosclerosis in ApoE−/− Mice With Unilateral Renal Artery Stenosis

    OpenAIRE

    Pathak, Alokkumar S.; Huang, Jianhua; Rojas, Mauricio; Bazemore, Taylor C.; Zhou, Ruihai; Stouffer, George A.

    2016-01-01

    Background Chronic unilateral renal artery stenosis (RAS) causes accelerated atherosclerosis in apolipoprotein E–deficient (ApoE−/−) mice, but effects of restoration of renal blood flow on aortic atherosclerosis are unknown. Methods and Results Male ApoE−/− mice underwent sham surgery (n=16) or had partial ligation of the right renal artery (n=41) with the ligature being removed 4 days later (D4LR; n=6), 8 days later (D8LR; n=11), or left in place for 90 days (chronic RAS; n=24). Ligature rem...

  9. The influence of hyperoxia on regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV) and cerebral blood flow velocity in the middle cerebral artery (CBFVMCA) in human volunteers.

    Science.gov (United States)

    Kolbitsch, Christian; Lorenz, Ingo H; Hörmann, Christoph; Hinteregger, Martin; Löckinger, Alexander; Moser, Patrizia L; Kremser, Christian; Schocke, Michael; Felber, Stephan; Pfeiffer, Karl P; Benzer, Arnulf

    2002-09-01

    Conflicting results reported on the effects of hyperoxia on cerebral hemodynamics have been attributed mainly to methodical and species differences. In the present study contrast-enhanced magnetic resonance imaging (MRI) perfusion measurement was used to analyze the influence of hyperoxia (fraction of inspired oxygen (FiO2) = 1.0) on regional cerebral blood flow (rCBF) and regional cerebral blood volume (rCBV) in awake, normoventilating volunteers (n = 19). Furthermore, the experiment was repeated in 20 volunteers for transcranial Doppler sonography (TCD) measurement of cerebral blood flow velocity in the middle cerebral artery (CBFV(MCA)). When compared to normoxia (FiO2 = 0.21), hyperoxia heterogeneously influenced rCBV (4.95 +/- 0.02 to 12.87 +/- 0.08 mL/100g (FiO2 = 0.21) vs. 4.50 +/- 0.02 to 13.09 +/- 0.09 mL/100g (FiO2 = 1.0). In contrast, hyperoxia diminished rCBF in all regions (68.08 +/- 0.38 to 199.58 +/- 1.58 mL/100g/min (FiO2 = 0.21) vs. 58.63 +/- 0.32 to 175.16 +/- 1.51 mL/100g/min (FiO2 = 1.0)) except in parietal and left frontal gray matter. CBFV(MCA) remained unchanged regardless of the inspired oxygen fraction (62 +/- 9 cm/s (FiO2 = 0.21) vs. 64 +/- 8 cm/s (FiO2 = 1.0)). Finding CBFV(MCA) unchanged during hyperoxia is consistent with the present study's unchanged rCBF in parietal and left frontal gray matter. In these fronto-parietal regions predominantly fed by the middle cerebral artery, the vasoconstrictor effect of oxygen was probably counteracted by increased perfusion of foci of neuronal activity controlling general behavior and arousal. PMID:12413599

  10. Haemodynamic evaluation of the cerebral circulation by periorbital Doppler examination and cerebral blood flow (CBF) measurement in carotid artery disease

    DEFF Research Database (Denmark)

    Sillesen, H; Schroeder, T; Buchardt Hansen, H J

    1988-01-01

    To assess the haemodynamic significance of an internal carotid artery (ICA) stenosis, angiography or direct ultrasound examination should be supplemented by indirect physiologic testing of the collateral circulation. Among the tests proposed, we used the periorbital flow direction, assessed by Do...

  11. Quantitation of myocardial blood flow and myocardial flow reserve with {sup 99m}Tc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, MO (United States); Chen, Fu-Chung; Chen, Chien-Cheng [Show Chwan Memorial Hospital, Section of Cardiology, Department of Internal Medicine, Changhua (China); Wu, Tao-Cheng [Taipei Veterans General Hospital, Section of Cardiology, Department of Internal Medicine, Taipei (China); Huang, Wen-Sheng [Changhua Christian Hospital, Department of Medical Research and Department of Nuclear Medicine, Changhua (China); Hou, Po-Nien [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Central Taiwan University of Science and Technology, Department of Medical Imaging and Radiological Science, Taichung (China); China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China)

    2014-12-15

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or <50 % stenosis). DySPECT and GSPECT scans were performed on a widely used dual-head SPECT/CT scanner. The DySPECT imaging protocol utilized 12-min multiple back-and-forth gantry rotations during injections of {sup 99m}Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a

  12. Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    International Nuclear Information System (INIS)

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or 99mTc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a conventional SPECT/CT system and the flow quantitation method is a clinically effective approach to enhance CAD detection. (orig.)

  13. The Cerebral Blood Flow Biomedical Informatics Research Network (CBFBIRN Database and Analysis Pipeline for Arterial Spin Labeling MRI Data

    Directory of Open Access Journals (Sweden)

    David D. Shin

    2013-10-01

    Full Text Available Arterial spin labeling (ASL is a MRI technique that provides a noninvasive and quantitative measure of cerebral blood flow (CBF. After more than a decade of active research, ASL is now emerging as a robust and reliable CBF measurement technique with increased availability and ease of use. There is a growing number of research and clinical sites using ASL for neuroscience research and clinical care. In this paper, we present an online CBF Database and Analysis Pipeline, collectively called the CBFBIRN that allows researchers to upload and share ASL and clinical data. In addition to serving the role as a central data repository, the CBFBIRN provides a streamlined data processing infrastructure for CBF quantification and group analysis, which has the potential to accelerate the discovery of new scientific and clinical knowledge. All capabilities and features built into the CBFBIRN are accessed online using a web browser through a secure login. In this work, we begin with a general description of the CBFBIRN system data model and its architecture, then devote the remainder of the paper to the CBFBIRN capabilities. The latter part of our work is divided into two processing modules: 1 Data Upload and CBF Quantification Module; 2 Group Analysis Module that supports three types of analysis commonly used in neuroscience research. To date, the CBFBIRN hosts CBF maps and associated clinical data from more than 1300 individual subjects. The data have been contributed by more than 20 different research studies, investigating the effect of various conditions on CBF including Alzheimer’s, schizophrenia, bipolar disorder, depression, traumatic brain injury, HIV, caffeine usage and Methamphetamine abuse. Several example results, generated by the CBFBIRN processing modules, are presented. We conclude with the lessons learned during implementation and deployment of the CBFBIRN and our experience in promoting data sharing.

  14. Cerebral blood flow changes in hemodialysis and peritoneal dialysis patients: an arterial-spin labeling MR imaging.

    Science.gov (United States)

    Jiang, Xiao Lu; Wen, Ji Qiu; Zhang, Long Jiang; Zheng, Gang; Li, Xue; Zhang, Zhe; Liu, Ya; Zheng, Li Juan; Wu, Long; Chen, Hui Juan; Kong, Xiang; Luo, Song; Lu, Guang Ming; Ji, Xue Man; Zhang, Zong Jun

    2016-08-01

    We used arterial-spin labeling (ASL) MR imaging, a non-invasive technique to evaluate cerebral blood flow (CBF) changes in patients with end-stage renal disease (ESRD) undergoing peritoneal dialysis (PD) and hemodialysis (HD), and nondialysis ESRD patients compared with healthy cohort. Ninety seven ESRD patients including 32 PD patients (20 male, 12 female; mean age 33 ± 8 years), 33 HD patients (22 male, 11 female; mean age 33 ± 8 years) and 32 nondialysis patients (20 male, 12 female; mean age 35 ± 7 years) and 31 age- and gender-matched healthy controls (20 male, 11 female; mean age 32 ± 8 years) were included in this study. All subjects underwent ASL MR imaging, neuropsychologic tests, and ESRD patients underwent laboratory testing. CBF values were compared among PD, HD, nondialysis patients and control groups. Correlation analysis and multiple regression analysis were performed to investigate the association between CBF values and hemoglobin, neuropsychologic test results, serum creatinine, urea levels, disease duration, and dialysis duration. Elevated CBFs of whole brain region, gray matter, and white matter were found in all ESRD patient groups compared with healthy controls (all P differences for CBF between PD and HD patient groups. Negative correlations were observed between mean CBFs of whole brain region, gray matter, and white matter and the hemoglobin level in all ESRD patients. Multiple linear regression showed elevated CBF of multiple brain areas correlated with some neuropsychological tests in ESRD patients (all P differences of CBF change and cognitive function between PD and HD ESRD patients with long-term treatment. The degree of anemia may be a predominant risk factor for cognitive impairment in these ESRD patients. PMID:27167984

  15. Left anterior descending coronary artery blood flow and left ventricular unloading during extracorporeal membrane oxygenation support in a swine model of acute cardiogenic shock.

    Science.gov (United States)

    Brehm, Christoph; Schubert, Sarah; Carney, Elizabeth; Ghodsizad, Ali; Koerner, Michael; McCoach, Robert; El-Banayosy, Aly

    2015-02-01

    The impact of extracorporeal membrane oxygenation (ECMO) support on coronary blood flow and left ventricular unloading is still debated. This study aimed to further characterize the influence of ECMO on coronary artery blood flow and its ability to unload the left ventricle in a short-term model of acute cardiogenic shock. Seven anesthetized pigs were intubated and then underwent median sternotomy and cannulation for venoarterial (VA) ECMO. Flow in the left anterior descending (LAD) artery, left atrial pressure (LAP), left ventricular end-diastolic pressure (LVEDP), and mean arterial pressure (MAP) were measured before and after esmolol-induced cardiac dysfunction and after initiating VA-ECMO support. Induction of acute cardiogenic shock was associated with short-term increases in LAP from 8 ± 4 mm Hg to 18 ± 14 mm Hg (P = 0.9) and LVEDP from 5 ± 2 mm Hg to 13 ± 17 mm Hg (P = 0.9), and a decrease in MAP from 63 ± 16 mm Hg to 50 ± 24 mm Hg (P = 0.3). With VA-ECMO support, blood flow in the LAD increased from 28 ± 25 mL/min during acute unsupported cardiogenic shock to 67 ± 50 mL/min (P = 0.003), and LAP and LVEDP decreased to 8 + 5 mm Hg (P = 0.7) and 5 ± 3 mm Hg (P = 0.5), respectively. In this swine model of acute cardiogenic shock, VA-ECMO improved coronary blood flow and provided some degree of left ventricular unloading for the short duration of the study. PMID:24935151

  16. Inflow/Outflow Boundary Conditions for Particle-Based Blood Flow Simulations: Application to Arterial Bifurcations and Trees.

    Directory of Open Access Journals (Sweden)

    Kirill Lykov

    2015-08-01

    Full Text Available When blood flows through a bifurcation, red blood cells (RBCs travel into side branches at different hematocrit levels, and it is even possible that all RBCs enter into one branch only, leading to a complete separation of plasma and RBCs. To quantify this phenomenon via particle-based mesoscopic simulations, we developed a general framework for open boundary conditions in multiphase flows that is effective even for high hematocrit levels. The inflow at the inlet is duplicated from a fully developed flow generated in a pilot simulation with periodic boundary conditions. The outflow is controlled by adaptive forces to maintain the flow rate and velocity gradient at fixed values, while the particles leaving the arteriole at the outlet are removed from the system. Upon validation of this approach, we performed systematic 3D simulations to study plasma skimming in arterioles of diameters 20 to 32 microns. For a flow rate ratio 6:1 at the branches, we observed the "all-or-nothing" phenomenon with plasma only entering the low flow rate branch. We then simulated blood-plasma separation in arteriolar bifurcations with different bifurcation angles and same diameter of the daughter branches. Our simulations predict a significant increase in RBC flux through the main daughter branch as the bifurcation angle is increased. Finally, we demonstrated the effectiveness of the new methodology in simulations of blood flow in vessels with multiple inlets and outlets, constructed using an angiogenesis model.

  17. [Comparative analysis of action of beta-phenyl derivatives of glutamic and gamma-aminobutyric acid on cerebral blood flow and cerebrovascular endothelium after irreversible occlusion of the common carotid artery].

    Science.gov (United States)

    Volotova, E V; Kurkin, D V; Mazina, N V; Berestovitskaia, V M; Vasil'eva, O S

    2013-01-01

    A comparative analysis of the effect of phenyl derivatives of glutamic (RGPU-135) and gamma-aminobutyric acid (Phenibut) on cerebral blood flow, vasodilatory endothelial function and the number of circulating endothelial cells desquamated in animals after irreversible occlusion of the common carotid arteries. It was found that animals treated prophylactically by RGPU-135, after occlusion of the common carotid arteries have higher cerebral blood flow and lower the severity of endothelial dysfunction than in animals treated with Phenibut. PMID:24003482

  18. Use of Caval Subtraction 2D Phase-Contrast MR Imaging to Measure Total Liver and Hepatic Arterial Blood Flow: Preclinical Validation and Initial Clinical Translation.

    Science.gov (United States)

    Chouhan, Manil D; Mookerjee, Rajeshwar P; Bainbridge, Alan; Walker-Samuel, Simon; Davies, Nathan; Halligan, Steve; Lythgoe, Mark F; Taylor, Stuart A

    2016-09-01

    Purpose To validate caval subtraction two-dimensional (2D) phase-contrast magnetic resonance (MR) imaging measurements of total liver blood flow (TLBF) and hepatic arterial fraction in an animal model and evaluate consistency and reproducibility in humans. Materials and Methods Approval from the institutional ethical committee for animal care and research ethics was obtained. Fifteen Sprague-Dawley rats underwent 2D phase-contrast MR imaging of the portal vein (PV) and infrahepatic and suprahepatic inferior vena cava (IVC). TLBF and hepatic arterial flow were estimated by subtracting infrahepatic from suprahepatic IVC flow and PV flow from estimated TLBF, respectively. Direct PV transit-time ultrasonography (US) and fluorescent microsphere measurements of hepatic arterial fraction were the standards of reference. Thereafter, consistency of caval subtraction phase-contrast MR imaging-derived TLBF and hepatic arterial flow was assessed in 13 volunteers (mean age, 28.3 years ± 1.4) against directly measured phase-contrast MR imaging PV and proper hepatic arterial inflow; reproducibility was measured after 7 days. Bland-Altman analysis of agreement and coefficient of variation comparisons were undertaken. Results There was good agreement between PV flow measured with phase-contrast MR imaging and that measured with transit-time US (mean difference, -3.5 mL/min/100 g; 95% limits of agreement [LOA], ±61.3 mL/min/100 g). Hepatic arterial fraction obtained with caval subtraction agreed well with those with fluorescent microspheres (mean difference, 4.2%; 95% LOA, ±20.5%). Good consistency was demonstrated between TLBF in humans measured with caval subtraction and direct inflow phase-contrast MR imaging (mean difference, -1.3 mL/min/100 g; 95% LOA, ±23.1 mL/min/100 g). TLBF reproducibility at 7 days was similar between the two methods (95% LOA, ±31.6 mL/min/100 g vs ±29.6 mL/min/100 g). Conclusion Caval subtraction phase-contrast MR imaging is a simple and clinically

  19. Computer Simulations of Pulsatile Human Blood Flow Through 3D-Models of the Human Aortic Arch, Vessels of Simple Geometry and a Bifurcated Artery: Investigation of Blood Viscosity and Turbulent Effects

    CERN Document Server

    Sultanov, Renat A

    2008-01-01

    We report computational results of blood flow through a model of the human aortic arch and a vessel of actual diameter and length. On the top of the aortic arch the branching of the %%three arteries are included: the subclavian and jugular. A realistic pulsatile flow is used in all simulations. Calculations for bifurcation type vessels are also carried out and presented. Different mathematical methods for numerical solution of the fluid dynamics equations have been considered. The non-Newtonian behaviour of the human blood is investigated together with turbulence effects. A detailed time-dependent mathematical convergence test has been carried out. The results of computer simulations of the blood flow in vessels of three different geometries are presented: for pressure, strain rate and velocity component distributions we found significant disagreements between our results obtained with realistic non-Newtonian treatment of human blood and the widely used method in the literature: a simple Newtonian approximati...

  20. Combined vector velocity and spectral Doppler imaging for improved imaging of complex blood flow in the carotid arteries.

    Science.gov (United States)

    Ekroll, Ingvild Kinn; Dahl, Torbjørn; Torp, Hans; Løvstakken, Lasse

    2014-07-01

    Color flow imaging and pulsed wave (PW) Doppler are important diagnostic tools in the examination of patients with carotid artery disease. However, measurement of the true peak systolic velocity is dependent on sample volume placement and the operator's ability to provide an educated guess of the flow direction. Using plane wave transmissions and a duplex imaging scheme, we present an all-in-one modality that provides both vector velocity and spectral Doppler imaging from one acquisition, in addition to separate B-mode images of sufficient quality. The vector Doppler information was used to provide automatically calibrated (angle-corrected) PW Doppler spectra at every image point. It was demonstrated that the combined information can be used to generate spatial maps of the peak systolic velocity, highlighting regions of high velocity and the extent of the stenotic region, which could be used to automate work flow as well as improve the accuracy of measurement of true peak systolic velocity. The modality was tested in a small group (N = 12) of patients with carotid artery disease. PW Doppler, vector velocity and B-mode images could successfully be obtained from a single recording for all patients with a body mass index ranging from 21 to 31 and a carotid depth ranging from 16 to 28 mm. PMID:24785436

  1. Fluid-structure interaction analysis on the effect of vessel wall hypertrophy and stiffness on the blood flow in carotid artery bifurcation

    Science.gov (United States)

    Lee, Sang Hoon; Choi, Hyoung Gwon; Yoo, Jung Yul

    2012-11-01

    The effect of artery wall hypertrophy and stiffness on the flow field is investigated using three-dimensional finite element method for simulating the blood flow. To avoid the complexity due to the necessity of additional mechanical constraints, we use the combined formulation which includes both the fluid and structural equations of motion into single coupled variational equation. A P2P1 Galerkin finite element method is used to solve the Navier-Stokes equations for fluid flow and arbitrary Lagrangian-Eulerian formulation is used to achieve mesh movement. The Newmark method is employed for solving the dynamic equilibrium equations for linear elastic solid mechanics. The pulsatile, incompressible flows of Newtonian fluids constrained in the flexible wall are analyzed with Womersley velocity profile at the inlet and constant pressure at the outlet. The study shows that the stiffness of carotid artery wall affects significantly the flow phenomena during the pulse cycle. Similarly, it is found that the flow field is also strongly influenced by wall hypertrophy. This work was supported by Mid-career Researcher Program and Priority Research Centers Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (2009-0079936 & 2011-0029613).

  2. A segmented K-space velocity mapping protocol for quantification of renal artery blood flow during breath-holding

    DEFF Research Database (Denmark)

    Thomsen, C; Cortsen, M; Söndergaard, L;

    1995-01-01

    segmented k-space technique, in which the entire data acquisition can be made within a breath-hold by the sampling of several phase-encoding lines within a small time window during each heart cycle. The aim of this study was to investigate the performance of a segmented k-space velocity mapping protocol for...... renal artery flow determination. The protocol uses 16 phase-encoding lines per heart beat during 16 heart cycles and gives a temporal velocity resolution of 160 msec. Comparison with a conventional ECG-triggered velocity mapping protocol was made in phantoms as well as in volunteers. In our study, both...

  3. Effects of detraining after blood flow-restricted low-load elastic band training on muscle size and arterial stiffness in older women

    OpenAIRE

    Yasuda, Tomohiro; Fukumura, Kazuya; Iida, Haruko; Nakajima, Toshiaki

    2015-01-01

    Background We examined the effects of detraining after blood flow-restricted (BFR) low-load elastic band training on muscle size and arterial stiffness in older women. Findings Fourteen women were divided into BFR training (BFR-T) or non-BFR training (CON-T). Each group participated in 12 weeks of arm curl and press down training using an elastic band either with (BFR-T) or without BFR (CON-T). Muscle cross-sectional area (CSA) and maximum voluntary isometric contraction (MVIC) for upper arms...

  4. Enhancing hippocampal blood flow after cerebral ischemia and vasodilating basilar arteries: in vivo and in vitro neuroprotective effect of antihypertensive DDPH

    Directory of Open Access Journals (Sweden)

    Li Sun

    2015-01-01

    Full Text Available 1-(2,6-Dimethylphenoxy-2-(3,4-dimethoxyphenylethylamino-propane hydrochloride (DDPH is a novel antihypertensive agent based on structural characteristics of mexiletine and verapamine. We investigated the effect of DDPH on vasodilatation and neuroprotection in a rat model of cerebral ischemia in vivo, and a rabbit model of isolated basilar arteries in vitro. Our results show that DDPH (10 mg/kg significantly increased hippocampal blood flow in vivo in cerebral ischemic rats, and exerted dose-dependent relaxation of isolated basilar arteries contracted by histamine or KCl in the in vitro rabbit model. DDPH (3 × 10 -5 M also inhibited histamine-stimulated extracellular calcium influx and intracellular calcium release. Our findings suggest that DDPH has a vasodilative effect both in vivo and in vitro, which mediates a neuroprotective effect on ischemic nerve tissue.

  5. Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study

    Directory of Open Access Journals (Sweden)

    Sayid Shafi Zuhur

    2012-01-01

    Full Text Available OBJECTIVE: To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. METHODS: The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease and 25 ageand sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. RESULTS: The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. CONCLUSIONS: This study suggests that the measurement of inferior thyroid artery-blood flow velocities with colorflow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.

  6. Circulation time determined by carotid angiography in patients with chronic internal Carotid artery occlusion. Comparison with cerebral blood flow and oxygen metabolism measured by PET

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Hiroshi; Inugami, Atsushi (Research Inst. for Brain and Blood Vessels, Akita (Japan)); Shishido, Fumio (and others)

    1994-10-01

    The degree of collateral circulation in patients with unilaterally chronic internal carotid artery occlusion was estimated by mean transit time of contrast material in rapid sequence carotid angiography (Angiographic MTT), and compared with cerebral blood flow and oxygen metabolism measured by PET. In normal density region on X-ray CT, a significant negative correlation was observed between Angiographic MTT and cerebral blood flow (CBF). This indicates that cerebral blood flow can be estimated by Angiographic MTT. It has been reported that the ratio of cerebral blood volume (CBV) to CBF (CBV/CBF), i.e., mean transit time determined by PET well agreed with OEF, and is good indicator for brain circulation reserve. In this study, no significant correlation was observed between Angiographic MTT and CBV/CBF. However, a significant positive correlation was observed between Angiographic MTT and oxygen extraction fraction (OEF), and no significant correlation was observed between Angiographic MTT and oxygen consumption rate (CMRO[sub 2]). These indicates that Angiographic MTT may be indicator for brain circulation reserve. (author).

  7. Pulmonary blood flow and pressure as well as arterial blood oxygenation simulations in ventilated artificial patient supported by continuous rotary blood pump.

    OpenAIRE

    ZielińSki, Krzysztof; Golczewski, Tomasz; Fresiello, Libera; Di Molfetta, Arianna; Ferrari, Gianfranco; Kozarski, Maciej; Darowski, Marek

    2011-01-01

    Objectives: Our previous study suggested insignificant impairment of pulmonary circulation during artificial ventilation if the inspiration time is smaller than the duration of 2-3 heart cycles. This was due to pulmonary blood volume periodic changes. The aim of this study is to analyze the influence of left ventricular assistance by continuous rotary blood pump (RBP) on hemodynamic in ventilated, virtual patient. Methods: Virtual RBP was added to a previously elaborated hybrid (pneumonumeric...

  8. Effects of Bolus and Continuous Nasogastric Feeding on Gastric Emptying, Small Bowel Water Content, Superior Mesenteric Artery Blood Flow, and Plasma Hormone Concentrations in Healthy Adults

    Science.gov (United States)

    Chowdhury, Abeed H.; Murray, Kathryn; Hoad, Caroline L.; Costigan, Carolyn; Marciani, Luca; Macdonald, Ian A.; Bowling, Timothy E.; Lobo, Dileep N.

    2016-01-01

    Objective: We aimed to demonstrate the effect of continuous or bolus nasogastric feeding on gastric emptying, small bowel water content, and splanchnic blood flow measured by magnetic resonance imaging (MRI) in the context of changes in plasma gastrointestinal hormone secretion. Background: Nasogastric/nasoenteral tube feeding is often complicated by diarrhea but the contribution of feeding strategy to the etiology is unclear. Methods: Twelve healthy adult male participants who underwent nasogastric intubation before a baseline MRI scan, received 400 mL of Resource Energy (Nestle) as a bolus over 5 minutes or continuously over 4 hours via pump in this randomized crossover study. Changes in gastric volume, small bowel water content, and superior mesenteric artery blood flow and velocity were measured over 4 hours using MRI and blood glucose and plasma concentrations of insulin, peptide YY, and ghrelin were assayed every 30 minutes. Results: Bolus nasogastric feeding led to significant elevations in gastric volume (P < 0.0001), superior mesenteric artery blood flow (P < 0.0001), and velocity (P = 0.0011) compared with continuous feeding. Both types of feeding reduced small bowel water content, although there was an increase in small bowel water content with bolus feeding after 90 minutes (P < 0.0068). Similarly, both types of feeding led to a fall in plasma ghrelin concentration although this fall was greater with bolus feeding (P < 0.0001). Bolus feeding also led to an increase in concentrations of insulin (P = 0.0024) and peptide YY (P < 0.0001), not seen with continuous feeding. Conclusion: Continuous nasogastric feeding does not increase small bowel water content, thus fluid flux within the small bowel is not a major contributor to the etiology of tube feeding-related diarrhea. PMID:25549202

  9. The effect of black tea and caffeine on regional cerebral blood flow measured with arterial spin labeling

    OpenAIRE

    Vidyasagar, Rishma; Greyling, Arno; Draijer, Richard; Corfield, Douglas R; Parkes, Laura M.

    2013-01-01

    Black tea consumption has been shown to improve peripheral vascular function. Its effect on brain vasculature is unknown, though tea contains small amounts of caffeine, a psychoactive substance known to influence cerebral blood flow (CBF). We investigated the effects on CBF due to the intake of tea components in 20 healthy men in a double-blinded, randomized, placebo-controlled study. On separate days, subjects received a single dose of 184 mg caffeine (equivalent to one strong espresso coffe...

  10. Evaluation of lumbar sympathectomy impact on the clinical course, blood flow parameters and muscle perfusion in a group of patients with peripheral arterial disease (PAD)

    International Nuclear Information System (INIS)

    Background: Occlusive arterial disease is a common disease. Frequently, at the time of diagnosis, disease severity prevents revascularization. The study evaluated lumbar sympathectomy influence on the clinical course, blood flow parameters and muscle perfusion. Material/Methods: Research group included 33 patients (13 women - 39.4 %, and 20 men - 60.6 %) aged from 47 to 81 (mean age 63.54 ± 8.63 years) treated for PAD and qualified to undergo lumbar sympathectomy. Physical examination, standard vascular tests (ankle-brachial, thigh-ankle and thigh-shin indices, maximum flow velocity, PI and RI in selected arteries), perfusion scintigraphy of lower limbs muscles at rest and on exertion were carried out before and 6 months after surgery. Results: Statistically significant increase of total walking distance (71.82 meters vs. 177.58 meters, p < 0.002) was detected. On the basis of participants feelings, the effect of treatment as a positive was declared by 30 of them, representing 90.9 % of the sample. Only 2 patients (6.1 %) identified treatment as not affecting their health condition, and 1 patient (3.0 %) reported worsening of symptoms after treatment. Standard vascular tests and perfusion scintigraphy did not reveal any significant changes. Conclusions: Lumbar sympathectomy in patients suffering from severe, atherosclerotic lower limb ischaemia brought positive effects such as increasing walking distance, decreasing rest pain or healing skin ulcers. This effect was not combined with improvement of muscle blood (ulcer healing). (authors)

  11. A lumped model for blood flow and pressure in the systemic arteries based on an approximate velocity profile function.

    Science.gov (United States)

    Huberts, Wouter; Bosboom, E Marielle H; van de Vosse, Frans N

    2009-01-01

    Previously, by assuming a viscous dominated flow in the boundary layer and an inertia dominated flow in the vessel core, a velocity profile function for a 1D-wave propagation model was derived. Because the time dependent shape of the velocity profile in this boundary layer model depends on the size of the inviscid core and the boundary layer, and thus on the Womersley number, it differs along the arterial tree. In this study we evaluated a lumped model for a vessel segment in which the element configuration is based on physical phenomena described by the boundary layer model and for which all parameters have a physically based quantitative value dependent on the Womersley numbers. The proposed electrical analog consists of a Womersley number dependent resistor and an inductor arranged in parallel, representing the flow impedence in respectively the vessel core and the boundary layer, in series with a second resistor. After incorporating a capacitor representing the vessel compliance in this rigid tube model, the element configuration resembles the configuration of the four-element windkessel model. For arbitrary Womersley numbers the relative impedence of Womersley theory is approximated with high accuracy. In the limits for small and large Womersley numbers the relative impedences of the proposed lumped model correspond exactly to Womersley theory. PMID:19292506

  12. Transesophageal echocardiography estimation of coronary sinus blood flow for the adequacy of revascularization in patients undergoing off-pump coronary artery bypass graft

    Directory of Open Access Journals (Sweden)

    P S Nagaraja

    2015-01-01

    Full Text Available Aims and Objectives: Physiologically coronary sinus (CS drains the left coronary artery (LCA territory. Stenosis of the branches of LCA may decrease the coronary sinus blood flow (CSBF. Any intervention that aims at restoring the flow of the stenosed vessel increases coronary artery flow that should consequently increase the CSBF. Hence, this study was undertaken to assess the CSBF before and after each branch of LCA to determine the adequacy of surgical revascularization in patients undergoing elective off pump coronary artery bypass grafting (OPCAB using transesophageal echocardiography (TEE. Materials and Methods: Thirty consecutive patients scheduled for elective OPCAB were enrolled. CSBF was assessed before and after each branch of LCA revascularization using TEE. Left internal mammary artery (LIMA Doppler was also obtained post LIMA to left anterior descending (LAD grafting. Results: Hemodynamic and echocardiographic variables were compared by means of Student′s t-test for paired data before and after revascularization. The CSBF per beat (1.28 ± 0.71, CSBF per minute (92.59 ± 59.32 and total velocity time integral (VTI (8.93 ± 4.29 before LAD grafting showed statistically significant increase to CSBF per beat (1.70 ± 0.89, CSBF per minute (130.72 ± 74.22 and total VTI (11.96 ± 5.68 after LAD revascularization. The CSBF per beat (1.67 ± 1.03, CSBF per minute (131.91 ± 86.59 and total VTI (11.00 ± 5.53 before obtuse marginal (OM grafting showed statistically significant increase to CSBF per beat (1.91 ± 1.03, CSBF per min (155.20 ± 88.70 and total VTI (12.09 ± 5.43 after OM revascularization. In 9 patients, color flow Doppler of LIMA could be demonstrated which showed diastolic predominant blood flow after LIMA to LAD grafting. Conclusion: Demonstration of CSBF was simple and monitoring the trend of CSBF values before and after each graft of LCA territory will guide to determine the adequacy of surgical revascularization.

  13. Regulation of pulpal blood flow

    International Nuclear Information System (INIS)

    The regulation of blood flow of the dental pulp was investigated in dogs and rats anesthetized with sodium pentobarbital. Pulpal blood flow was altered by variations of local and systemic hemodynamics. Macrocirculatory blood flow (ml/min/100 g) in the dental pulp was measured with both the 133Xe washout and the 15-microns radioisotope-labeled microsphere injection methods on the canine teeth of dogs, to provide a comparison of the two methods in the same tooth. Microcirculatory studies were conducted in the rat incisor tooth with microscopic determination of the vascular pattern, RBC velocity, and intravascular volumetric flow distribution. Pulpal resistance vessels have alpha- and beta-adrenergic receptors. Activation of alpha-receptors by intra-arterial injection of norepinephrine (NE) caused both a reduction in macrocirculatory Qp in dogs and decreases in arteriolar and venular diameters and intravascular volumetric flow (Qi) in rats. These responses were blocked by the alpha-antagonist PBZ. Activation of beta-receptors by intra-arterial injection of isoproterenal (ISO) caused a paradoxical reduction of Qp in dogs. In rats, ISO caused a transient increase in arteriolar Qi followed by a flow reduction; arteriolar dilation was accompanied by venular constriction. These macrocirculatory and microcirculatory responses to ISO were blocked by the alpha-antagonist propranolol

  14. Reduced blood flow response to acetazolamide reflects pre-existing vasodilation and decreased oxygen metabolism in major cerebral arterial occlusive disease

    International Nuclear Information System (INIS)

    A decrease in the cerebral blood flow (CBF) response to acetazolamide may indicate an increase in cerebral blood volume (CBV) caused by reduced perfusion pressure in patients with major cerebral artery steno-occlusive lesions. However, a decrease in cerebral metabolic rate of oxygen (CMRO2) caused by ischemic changes may also decrease the CBF response to acetazolamide by decreasing the production of carbon dioxide. The purpose of this study was to determine whether the values of CBV and CMRO2 are independent predictors of the CBF response to acetazolamide in major cerebral arterial occlusive disease. We used positron emission tomography to study 30 patients with major cerebral artery steno-occlusive lesions. The CBF response to acetazolamide was assessed by measuring baseline CBF and CBF 10 min after an intravenous injection of 1 g of acetazolamide. Multivariate analysis was used to test the independent predictive value of the CBV and CMRO2 at baseline with respect to the percent change in CBF during acetazolamide administration. Both increased CBV and decreased CMRO2 were significant and independent predictors of the reduced CBF response to acetazolamide. CBV accounted for 25% of the variance in the absolute change in CBF during acetazolamide administration and 42% of the variance in the percent change in CBF, whereas CMRO2 accounted for 19% and 4% of the variance, respectively. In patients with major cerebral arterial occlusive disease, a decrease in CMRO2 may contribute to the reduced CBF response to acetazolamide, although an increase in CBV appears to be the major contributing factor. (orig.)

  15. The Effect of Varied Support Models of BJUT-IIVAD on Coronary Arterial blood flow and wall shear stress: A Primary CFD Study.

    Science.gov (United States)

    Zhang, Qi; Gao, Bin; Gu, Kaiyun; Chang, Yu; Xu, Jinchao; Deuflhard, Peter

    2014-09-17

    BJUT-II VAD is a novel left ventricular assist devices. Because of the special connection between the pump and native heart, the hemodynamic effects of BJTU-II VAD on coronary artery are still unclear. Hence, numerical simulations have conducted to clarify changes in hemodynamic effects of different support modes. A patient specific left coronary arterial geometric model is reconstructed based on the CT data. And 3 support modes, "constant speed mode", "co-pulse modes" and "counter pulse mode" are used in this study. The wall shear stress (WSS), wall shear stress gradient (WSSG), cycle averaged wall shear stress (avWSS), oscillatory shear index (OSI) and the flow pattern are calculated to evaluate the hemodynamic states of coronary artery. The computational results demonstrate that the hemodynamic states of coronary artery are directly affected by the support modes. The co-pulse modes could achieve the highest blood perfusion (constant speed: 153ml/min vs. co-pulse: 775ml/min vs. counter pulse: 140ml/min) and the highest avWSS (constant speed: 18.1Pa vs. co-pulse: 42.6Pa vs. counter pulse: 22.6Pa). In addition, the WSS and WSSG at the time of peak blood velocity under the constant speed mode are both lower than those under other two support modes. In contrast, the counter pulse mode generates the highest OSI value (constant speed: 0.365 vs. co-pulse: 0.379 vs. counter pulse: 0.426). In brief, BJUT-II VAD under co-pulse mode may have benefits for improving coronary perfusion and preventing the development of atherosclerosis, however, the constant speed mode may have benefit for preventing the development of plaque vulnerability. PMID:25232766

  16. Flow Cytometric Quantification of Peripheral Blood Cell β-Adrenergic Receptor Density and Urinary Endothelial Cell-Derived Microparticles in Pulmonary Arterial Hypertension.

    Directory of Open Access Journals (Sweden)

    Jonathan A Rose

    Full Text Available Pulmonary arterial hypertension (PAH is a heterogeneous disease characterized by severe angiogenic remodeling of the pulmonary artery wall and right ventricular hypertrophy. Thus, there is an increasing need for novel biomarkers to dissect disease heterogeneity, and predict treatment response. Although β-adrenergic receptor (βAR dysfunction is well documented in left heart disease while endothelial cell-derived microparticles (Ec-MPs are established biomarkers of angiogenic remodeling, methods for easy large clinical cohort analysis of these biomarkers are currently absent. Here we describe flow cytometric methods for quantification of βAR density on circulating white blood cells (WBC and Ec-MPs in urine samples that can be used as potential biomarkers of right heart failure in PAH. Biotinylated β-blocker alprenolol was synthesized and validated as a βAR specific probe that was combined with immunophenotyping to quantify βAR density in circulating WBC subsets. Ec-MPs obtained from urine samples were stained for annexin-V and CD144, and analyzed by a micro flow cytometer. Flow cytometric detection of alprenolol showed that βAR density was decreased in most WBC subsets in PAH samples compared to healthy controls. Ec-MPs in urine was increased in PAH compared to controls. Furthermore, there was a direct correlation between Ec-MPs and Tricuspid annular plane systolic excursion (TAPSE in PAH patients. Therefore, flow cytometric quantification of peripheral blood cell βAR density and urinary Ec-MPs may be useful as potential biomarkers of right ventricular function in PAH.

  17. Flow Cytometric Quantification of Peripheral Blood Cell β-Adrenergic Receptor Density and Urinary Endothelial Cell-Derived Microparticles in Pulmonary Arterial Hypertension

    Science.gov (United States)

    Rose, Jonathan A.; Wanner, Nicholas; Cheong, Hoi I.; Queisser, Kimberly; Barrett, Patrick; Park, Margaret; Hite, Corrine; Naga Prasad, Sathyamangla V.; Erzurum, Serpil; Asosingh, Kewal

    2016-01-01

    Pulmonary arterial hypertension (PAH) is a heterogeneous disease characterized by severe angiogenic remodeling of the pulmonary artery wall and right ventricular hypertrophy. Thus, there is an increasing need for novel biomarkers to dissect disease heterogeneity, and predict treatment response. Although β-adrenergic receptor (βAR) dysfunction is well documented in left heart disease while endothelial cell-derived microparticles (Ec-MPs) are established biomarkers of angiogenic remodeling, methods for easy large clinical cohort analysis of these biomarkers are currently absent. Here we describe flow cytometric methods for quantification of βAR density on circulating white blood cells (WBC) and Ec-MPs in urine samples that can be used as potential biomarkers of right heart failure in PAH. Biotinylated β-blocker alprenolol was synthesized and validated as a βAR specific probe that was combined with immunophenotyping to quantify βAR density in circulating WBC subsets. Ec-MPs obtained from urine samples were stained for annexin-V and CD144, and analyzed by a micro flow cytometer. Flow cytometric detection of alprenolol showed that βAR density was decreased in most WBC subsets in PAH samples compared to healthy controls. Ec-MPs in urine was increased in PAH compared to controls. Furthermore, there was a direct correlation between Ec-MPs and Tricuspid annular plane systolic excursion (TAPSE) in PAH patients. Therefore, flow cytometric quantification of peripheral blood cell βAR density and urinary Ec-MPs may be useful as potential biomarkers of right ventricular function in PAH. PMID:27270458

  18. Rarefaction and blood pressure in systemic and pulmonary arteries.

    Science.gov (United States)

    Olufsen, Mette S; Hill, N A; Vaughan, Gareth D A; Sainsbury, Christopher; Johnson, Martin

    2012-08-01

    The effects of vascular rarefaction (the loss of small arteries) on the circulation of blood are studied using a multiscale mathematical model that can predict blood flow and pressure in the systemic and pulmonary arteries. We augmented a model originally developed for the systemic arteries (Olufsen et al. 1998, 1999, 2000, 2004) to (a) predict flow and pressure in the pulmonary arteries, and (b) predict pressure propagation along the small arteries in the vascular beds. The systemic and pulmonary arteries are modelled as separate, bifurcating trees of compliant and tapering vessels. Each tree is divided into two parts representing the `large' and `small' arteries. Blood flow and pressure in the large arteries are predicted using a nonlinear cross-sectional area-averaged model for a Newtonian fluid in an elastic tube with inflow obtained from magnetic resonance measurements. Each terminal vessel within the network of the large arteries is coupled to a vascular bed of small `resistance' arteries, which are modelled as asymmetric structured trees with specified area and asymmetry ratios between the parent and daughter arteries. For the systemic circulation, each structured tree represents a specific vascular bed corresponding to major organs and limbs. For the pulmonary circulation, there are four vascular beds supplied by the interlobar arteries. This manuscript presents the first theoretical calculations of the propagation of the pressure and flow waves along systemic and pulmonary large and small arteries. Results for all networks were in agreement with published observations. Two studies were done with this model. First, we showed how rarefaction can be modelled by pruning the tree of arteries in the microvascular system. This was done by modulating parameters used for designing the structured trees. Results showed that rarefaction leads to increased mean and decreased pulse pressure in the large arteries. Second, we investigated the impact of decreasing vessel

  19. Hyperhomocysteinemia decreases bone blood flow

    Directory of Open Access Journals (Sweden)

    Neetu Tyagi

    2011-01-01

    Full Text Available Neetu Tyagi*, Thomas P Vacek*, John T Fleming, Jonathan C Vacek, Suresh C TyagiDepartment of Physiology and Biophysics, School of Medicine, University of Louisville, Louisville, KY, USA *These authors have equal authorshipAbstract: Elevated plasma levels of homocysteine (Hcy, known as hyperhomocysteinemia (HHcy, are associated with osteoporosis. A decrease in bone blood flow is a potential cause of compromised bone mechanical properties. Therefore, we hypothesized that HHcy decreases bone blood flow and biomechanical properties. To test this hypothesis, male Sprague–Dawley rats were treated with Hcy (0.67 g/L in drinking water for 8 weeks. Age-matched rats served as controls. At the end of the treatment period, the rats were anesthetized. Blood samples were collected from experimental or control rats. Biochemical turnover markers (body weight, Hcy, vitamin B12, and folate were measured. Systolic blood pressure was measured from the right carotid artery. Tibia blood flow was measured by laser Doppler flow probe. The results indicated that Hcy levels were significantly higher in the Hcy-treated group than in control rats, whereas vitamin B12 levels were lower in the Hcy-treated group compared with control rats. There was no significant difference in folate concentration and blood pressure in Hcy-treated versus control rats. The tibial blood flow index of the control group was significantly higher (0.78 ± 0.09 flow unit compared with the Hcy-treated group (0.51 ± 0.09. The tibial mass was 1.1 ± 0.1 g in the control group and 0.9 ± 0.1 in the Hcy-treated group. The tibia bone density was unchanged in Hcy-treated rats. These results suggest that Hcy causes a reduction in bone blood flow, which contributes to compromised bone biomechanical properties.Keywords: homocysteine, tibia, bone density

  20. The Pilot Study of Evaluating Fluctuation in the Blood Flow Volume of the Radial Artery, a Site for Traditional Pulse Diagnosis

    Directory of Open Access Journals (Sweden)

    Masashi Watanabe

    2016-05-01

    Full Text Available Background: Radial artery (RA pulse diagnosis has been used in traditional Asian medicine. Blood pressure (BP and pulse rate related to heart rate variability (HRV can be monitored via the RA. The fluctuation in these parameters has been assessed using fast Fourier transform (FFT analytical methods that calculate power spectra. Methods: We measured blood flow volume (Volume in the RA and evaluated its fluctuations. Normal participants (n = 34 were enrolled. We measured the hemodynamics of the right RA for approximately 50 s using ultrasonography. Results: The parameters showed the center frequency (CF of the power spectrum at low frequency (LF and high frequency (HF. More than one spectral component indicated that there were fluctuations. The CF at LF for Volume was significantly different from that for vessel diameter (VD; however, it was significantly correlated with blood flow velocity (Velocity. On the other hand, the CF at HF for Volume was significantly different from that for Velocity; however, it was significantly correlated with VD. Conclusion: It is suggested that fluctuation in the Volume at LF of RA is influenced by the fluctuation in Velocity; on the other hand, fluctuation in the Volume at HF is influenced by the fluctuation in VD.

  1. [Abnormal cerebral blood flow distributions during the post-ictal phase of febrile status epilepticus in three pediatric patients measured by arterial spin labeling perfusion MRI].

    Science.gov (United States)

    Hirano, Keiko; Fukuda, Tokiko

    2016-05-01

    The ability to visualize brain perfusion is important for identifying epileptic foci. We present three pediatric cases showing asymmetrical cerebral blood flow (CBF) distributions during the post-ictal phase of febrile status epilepticus measured by arterial spin labeling (ASL) perfusion MRI. During the acute phase, regional CBF measurements in the areas considered including epileptic foci were higher than in the corresponding area of the contralateral hemisphere, though the exact quantitative value varied between cases. We could not identify the correct epileptogenic foci, because those ASL images were taken after the prolonged and extraordinary activation of neurons in the affected area. During the recovery phase, the differences reduced and the average regional CBF measurement was 54.6 ± 6.1 ml/100 g per minute, which was a little less than the number of previous ASL studies. ASL perfusion MRI imaging provides a method for evaluating regional CBF by using magnetically labeled arterial blood water as an endogenous tracer. With this technique, we can repeatedly evaluate both the brain structure and the level of perfusion at the same time. ASL is noninvasive and easily accessible, and therefore it could become a routine tool for assessment of perfusion in daily practice of pediatric neurology. PMID:27349086

  2. Four-Dimensional Visualization of Thoracic Blood Flow by Magnetic Resonance Imaging in a Patient Following Correction of Transposition of the Great Arteries (d-TGA) and Uncorrected Aortic Coarctation

    International Nuclear Information System (INIS)

    Recent advances in flow-sensitive magnetic resonance imaging (MRI) and data analysis allow for comprehensive noninvasive three-dimensional (3D) visualization of complex blood flow. Electrocardiogram (ECG)-gated three-directional (3dir) flow measurements were employed to assess and visualize time-resolved 3D blood flow in the pulmonary arteries (PA) and thoracic aorta. We present findings in a juvenile patient with surgically corrected transposition of the great arteries (d-TGA) and aortic coarctation. For the first time, the complex flow patterns in the PA following d-TGA were visualized. Morphologically, a slight asymmetry of the PA was found, with considerable impact on vascular hemodynamics, resulting in diastolic retrograde flow in the larger vessel and diastolic filling of the smaller PA. Additionally, increased flow to the supraaortic vessels was found due to aortic coarctation

  3. Comparison of blood velocity measurements between ultrasound Doppler and accelerated phase-contrast MR angiography in small arteries with disturbed flow

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Jingfeng; Johnson, Kevin; Wieben, Oliver; Zagzebski, James [Medical Physics Department, University of Wisconsin-Madison School of Medicine and Public Health, WI (United States); Strother, Charles; Consigny, Dan [Radiology Department, University of Wisconsin-Madison School of Medicine and Public Health, WI (United States); Baker, Sara, E-mail: jjiang2@wisc.edu [School of Ultrasound, University of Wisconsin-Madison School of Medicine and Public Health, WI (United States)

    2011-03-21

    Ultrasound Doppler (UD) velocity measurements are commonly used to quantify blood flow velocities in vivo. The aim of our work was to investigate the accuracy of in vivo spectral Doppler measurements of velocity waveforms. Waveforms were derived from spectral Doppler signals and corrected for intrinsic spectral broadening errors by applying a previously published algorithm. The method was tested in a canine aneurysm model by determining velocities in small arteries (3-4 mm diameter) near the aneurysm where there was moderately disturbed flow. Doppler results were compared to velocity measurements in the same arteries acquired with a rapid volumetric phase contrast MR angiography technique named phase contrast vastly undersampled isotropic projection reconstruction magnetic resonance angiography (PC-VIPR MRA). After correcting for intrinsic spectral broadening, there was a high degree of correlation between velocities obtained by the real-time UD and the accelerated PC-MRA technique. The peak systolic velocity yielded a linear correlation coefficient of r = 0.83, end diastolic velocity resulted in r = 0.81, and temporally averaged mean velocity resulted in r = 0.76. The overall velocity waveforms obtained by the two techniques were also highly correlated (r = 0.89 {+-} 0.06). There were, however, only weak correlations for the pulsatility index (PI: 0.25) and resistive index (RI: 0.14) derived from the two techniques. Results demonstrate that to avoid overestimations of peak systolic velocities, the results for UD must be carefully corrected to compensate for errors caused by intrinsic spectral broadening.

  4. Assessment of liver circulation by quantitative scintiangiography: Evaluation of the relative contribution of the hepatic arterial and portal venous blood flows to liver perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Molino, G.; Squadrone, E.; Baccegal, M.; Magnani, C.

    1989-04-01

    Quantitative hepatic scintiangiography was previously used for evaluating the relative contribution of hepatic arterial and portal venous blood flows to the hepatic circulation. The present study compares 3 different procedures (automatic and manual integration, and slope fitting methods) for analyzing the hepatic time activity curves obtained after bolus i.v. injection of 370 MBq /sup 99m/Tc-diethylentriaminopentacetic acid. Twenty five subjects were studied: Five controls, ten cirrhotics, and ten portal hypertensive patients previously submitted to side to side portacaval anastomosis. The correspondence between results given by the different methods was satisfactory only in shunted patients, and the reproducibility of computed parameters was quite poor for all procedures. Accordingly, none of the methods can be considered as supporting reliable quantitative pathophysiological evaluations. However, the hepatic arterial/portal venous flow ratio was found to be increased in liver cirrhosis and in shunted patients and therefore, in spite of the limitations underlined before and of the absence of data on the reproducibility of consecutive injections, hepatic scintiangiography may be of some clinical utility.

  5. Assessment of liver circulation by quantitative scintiangiography: Evaluation of the relative contribution of the hepatic arterial and portal venous blood flows to liver perfusion

    International Nuclear Information System (INIS)

    Quantitative hepatic scintiangiography was previously used for evaluating the relative contribution of hepatic arterial and portal venous blood flows to the hepatic circulation. The present study compares 3 different procedures (automatic and manual integration, and slope fitting methods) for analyzing the hepatic time activity curves obtained after bolus i.v. injection of 370 MBq 99mTc-diethylentriaminopentacetic acid. Twenty five subjects were studied: Five controls, ten cirrhotics, and ten portal hypertensive patients previously submitted to side to side portacaval anastomosis. The correspondence between results given by the different methods was satisfactory only in shunted patients, and the reproducibility of computed parameters was quite poor for all procedures. Accordingly, none of the methods can be considered as supporting reliable quantitative pathophysiological evaluations. However, the hepatic arterial/portal venous flow ratio was found to be increased in liver cirrhosis and in shunted patients and therefore, in spite of the limitations underlined before and of the absence of data on the reproducibility of consecutive injections, hepatic scintiangiography may be of some clinical utility. (orig.)

  6. Study on sEng, VEGF, PLGF, and sFlt-1 levels, and umbilical artery blood flow change in the pregnant women with preeclampsia

    Institute of Scientific and Technical Information of China (English)

    Xia Liu

    2016-01-01

    Objective:To observe sEng, VEGF, PLGF, and sFlt-1 levels, and umbilical artery blood flow change in the pregnant women with preeclampsia (PE), and their clinical significance.Methods:A total of 60 pregnant women with moderate and severe PE who were admitted in our hospital from January, 2014 to April, 2015 were included in the study and divided into the observation group 1 and observation group 2 with 30 cases in each group. ELISA was used to detect the levels of serum sEng, VEGF, PLGF, and sFlt-1. The color Doppler Ultrasound Diagnosis Apparatus was used to detect the changes of S/D, and RI. A total of 30 pregnant women who came for antenatal examination at the same period were served as the control group.Results:The levels of serum sEng, and sFlt-1 in the observation group 1 and 2 were significantly higher than those in the control group. The levels of serum sEng, and sFlt-1 in the observation group 2 were significantly higher than those in the observation group 1. The levels of serum VEGF and PLGF in the observation group 1 and 2 were significantly lower than those in the control group. The levels of serum VEGF and PLGF in the observation group were significantly lower than those in the observation group 1. S/D, and RI in the observation group 1 and 2 were significantly higher than those in the control group. S/D, and RI in the observation group 2 were significantly higher than those in the observation group 1.Conclusions:The serum sEng, VEGF, PLGF, and sFlt-1 levels are associated with PE, detection of which can accurately estimate the severity degree of PE, and determination of the umbilical artery blood flow can also accurately reflect PE condition.

  7. Caffeine impairs myocardial blood flow response to physical exercise in patients with coronary artery disease as well as in age-matched controls.

    Directory of Open Access Journals (Sweden)

    Mehdi Namdar

    Full Text Available BACKGROUND: Caffeine is one of the most widely consumed pharmacologically active substances. Its acute effect on myocardial blood flow is widely unknown. Our aim was to assess the acute effect of caffeine in a dose corresponding to two cups of coffee on myocardial blood flow (MBF in coronary artery disease (CAD. METHODOLOGY/PRINCIPAL FINDINGS: MBF was measured with (15O-labelled H2O and Positron Emission Tomography (PET at rest and after supine bicycle exercise in controls (n = 15, mean age 58+/-13 years and in CAD patients (n = 15, mean age 61+/-9 years. In the latter, regional MBF was assessed in segments subtended by stenotic and remote coronary arteries. All measurements were repeated fifty minutes after oral caffeine ingestion (200 mg. Myocardial perfusion reserve (MPR was calculated as ratio of MBF during bicycle stress divided by MBF at rest. Resting MBF was not affected by caffeine in both groups. Exercise-induced MBF response decreased significantly after caffeine in controls (2.26+/-0.56 vs. 2.02+/-0.56, P<0.005, remote (2.40+/-0.70 vs. 1.78+/-0.46, P<0.001 and in stenotic segments (1.90+/-0.41 vs. 1.38+/-0.30, P<0.001. Caffeine decreased MPR significantly by 14% in controls (P<0.05 vs. baseline. In CAD patients MPR decreased by 18% (P<0.05 vs. baseline in remote and by 25% in stenotic segments (P<0.01 vs. baseline. CONCLUSIONS: We conclude that caffeine impairs exercise-induced hyperaemic MBF response in patients with CAD to a greater degree than age-matched controls.

  8. Renal blood flow using arterial spin labelling MRI and calculated filtration fraction in healthy adult kidney donors pre-nephrectomy and post-nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Cutajar, Marica; Clark, Christopher A.; Gordon, Isky [University College London, Imaging and Biophysics Unit, Institute of Child Health, London (United Kingdom); Hilton, Rachel; Olsburgh, Jonathon [Renal Unit, Guy' s and St Thomas' NHS Foundation Trust, London (United Kingdom); Marks, Stephen D. [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Paediatric Nephrology, London (United Kingdom); Thomas, David L. [University College London, Department of Brain Repair and Rehabilitation, Institute of Neurology, London (United Kingdom); Banks, Tina [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Radiology, London (United Kingdom)

    2015-08-15

    Renal plasma flow (RPF) (derived from renal blood flow, RBF) and glomerular filtration rate (GFR) allow the determination of the filtration fraction (FF), which may have a role as a non-invasive renal biomarker. This is a hypothesis-generating pilot study assessing the effect of nephrectomy on renal function in healthy kidney donors. Eight living kidney donors underwent arterial spin labelling (ASL) magnetic resonance imaging (MRI) and GFR measurement prior to and 1 year after nephrectomy. Chromium-51 labelled ethylenediamine tetraacetic acid ({sup 51}Cr-EDTA) with multi-blood sampling was undertaken and GFR calculated. The RBF and GFR obtained were used to calculate FF. All donors showed an increase in single kidney GFR of 24 - 75 %, and all but two showed an increase in FF (-7 to +52 %) after nephrectomy. The increase in RBF, and hence RPF, post-nephrectomy was not as great as the increase in GFR in seven out of eight donors. As with any pilot study, the small number of donors and their relatively narrow age range are potential limiting factors. The ability to measure RBF, and hence RPF, non-invasively, coupled with GFR measurement, allows calculation of FF, a biomarker that might provide a sensitive indicator of loss of renal reserve in potential donors. (orig.)

  9. Renal blood flow using arterial spin labelling MRI and calculated filtration fraction in healthy adult kidney donors pre-nephrectomy and post-nephrectomy

    International Nuclear Information System (INIS)

    Renal plasma flow (RPF) (derived from renal blood flow, RBF) and glomerular filtration rate (GFR) allow the determination of the filtration fraction (FF), which may have a role as a non-invasive renal biomarker. This is a hypothesis-generating pilot study assessing the effect of nephrectomy on renal function in healthy kidney donors. Eight living kidney donors underwent arterial spin labelling (ASL) magnetic resonance imaging (MRI) and GFR measurement prior to and 1 year after nephrectomy. Chromium-51 labelled ethylenediamine tetraacetic acid (51Cr-EDTA) with multi-blood sampling was undertaken and GFR calculated. The RBF and GFR obtained were used to calculate FF. All donors showed an increase in single kidney GFR of 24 - 75 %, and all but two showed an increase in FF (-7 to +52 %) after nephrectomy. The increase in RBF, and hence RPF, post-nephrectomy was not as great as the increase in GFR in seven out of eight donors. As with any pilot study, the small number of donors and their relatively narrow age range are potential limiting factors. The ability to measure RBF, and hence RPF, non-invasively, coupled with GFR measurement, allows calculation of FF, a biomarker that might provide a sensitive indicator of loss of renal reserve in potential donors. (orig.)

  10. Blood flow autoregulation in pedicled flaps

    DEFF Research Database (Denmark)

    Bonde, Christian T; Holstein-Rathlou, Niels-Henrik; Elberg, Jens J

    2009-01-01

    INTRODUCTION: Clinical work on the blood perfusion in skin and muscle flaps has suggested that some degree of blood flow autoregulation exists in such flaps. An autoregulatory mechanism would enable the flap to protect itself from changes in the perfusion pressure. The purpose of the present study...... was to evaluate if, and to what extent, a tissue flap could compensate a reduction in blood flow due to an acute constriction of the feed artery. Further, we wanted to examine the possible role of smooth muscle L-type calcium channels in the autoregulatory mechanism by pharmacological intervention...... with the L-type calcium channel blocker nimodipine and the vasodilator papaverine. MATERIAL AND METHODS: Pedicled flaps were raised in pigs. Flow in the pedicle was reduced by constriction of the feed artery (n=34). A transit time flow probe measured the effect on blood flow continuously. Following...

  11. ROLE OF COLOUR DOPPLER: CEREBRAL AND UMBILICAL ARTERIAL BLOOD FLOW VELOCITY IN NORMAL AND GROWTH RESTRICTED PREGNANCY

    OpenAIRE

    Patange; Neha

    2014-01-01

    INTRODUCTION: Doppler velocimetry is a rapid noninvasive test that provides valuable information about haemodynamic situation of the foetus and is an efficient diagnostic test of foetal jeopardy which helps in timely intervention and management of high risk pregnancy for better perinatal outcome. OBJECTIVES: To evaluate middle cerebral artery and umbilical arterial velocity waveforms and their various indices during third trimester of pregnancy. METHODOLOGY: Prospective st...

  12. Bone blood flow and metabolism in humans

    DEFF Research Database (Denmark)

    Heinonen, Ilkka; Kemppainen, Jukka; Kaskinoro, Kimmo;

    2012-01-01

    femoral bone at rest and during one leg intermittent isometric exercise with increasing exercise intensities. In nine men, blood flow in femur was determined at rest and during dynamic one leg exercise, and two other physiological perturbations: moderate systemic hypoxia (14 O(2) ) at rest and during...... contralateral leg. In conclusion, resting femoral bone blood flow increases by physical exercise, but appears to level off with increasing exercise intensities. Moreover, while moderate systemic hypoxia does not change bone blood flow at rest or during exercise, intra-arterially administered adenosine during......Human bone blood flow and metabolism during physical exercise remains poorly characterised. In the present study we measured femoral bone blood flow and glucose uptake in young healthy subjects by positron emission tomography in three separate protocols. In six women, blood flow was measured in...

  13. Arterial Wall Properties and Womersley Flow in Fabry Disease

    Directory of Open Access Journals (Sweden)

    Dimitriadis Emilios

    2002-01-01

    Full Text Available Abstract Background Fabry disease is an X-linked recessive lysosomal storage disease resulting in the cellular accumulation of globotriaosylceramide particularly globotriaosylceramide. The disease is characterized by a dilated vasculopathy with arterial ectasia in muscular arteries and arterioles. Previous venous plethysomographic studies suggest enhanced endothelium-dependent vasodilation in Fabry disease indicating a functional abnormality of resistance vessels. Methods We examined the mechanical properties of the radial artery in Fabry disease, a typical fibro-muscular artery. Eight control subjects and seven patients with Fabry disease had a right brachial arterial line placed allowing real time recording of intra-arterial blood pressure. Real time B-mode ultrasound recordings of the right radial artery were obtained simultaneously allowing calculation of the vessel wall internal and external diameter, the incremental Young's modulus and arterial wall thickness. By simultaneously measurement of the distal index finger-pulse oximetry the pulse wave speed was calculated. From the wave speed and the internal radial artery diameter the volume flow was calculated by Womersley analysis following truncation of the late diastolic phase. Results No significant difference was found between Fabry patients and controls for internal or external arterial diameters, the incremental Young's modulus, the arterial wall thickness, the pulse wave speed and the basal radial artery blood flow. Further, no significant difference was found for the radial artery blood flow in response to intra-arterial acetylcholine or sodium nitroprusside. Both drugs however, elevated the mean arterial flow. Conclusions The current study suggests that no structural or mechanical abnormality exists in the vessel wall of fibro-muscular arteries in Fabry disease. This may indicate that a functional abnormality downstream to the conductance vessels is the dominant feature in

  14. Induction of PDE5 and de-sensitization to endogenous NO signaling in a systemic resistance artery under altered blood flow.

    Science.gov (United States)

    Zhang, Haiying; Pakeerappa, Praveen; Lee, Hyon Jae; Fisher, Steven A

    2009-07-01

    In the classical pathway, the opposing activities of guanylyl cyclases (GC) and phosphodiesterases (PDE), and the effect of the cGMP-dependent protein kinase (cGK) on its targets, determine the biological responses to NO signaling. Here we tested the hypothesis that vascular dysfunction may be due to altered expression and activity of these effectors of NO signaling. Every other set of rat second order mesenteric resistance arteries (MA) were ligated, resulting in chronic low flow (LF) in the upstream MA1 and high flow (HF) in the adjacent MA1 without tissue ischemia. eNOS and iNOS were up-regulated in HF and LF MA1, respectively, in the sub-acute phase (four days) of vascular remodeling. The Day4 HF/LF MA1s were under increased control of NO as indicated by reduced sensitivity to the vasoconstrictor phenylephrine and its normalization with the NOS antagonist L-NAME. PDE5 mRNA and protein were also significantly up-regulated in the HF/LF MA1 with no change in sGC or PKG1, an effect that was dependent upon NO synthesis. The PDE5 inhibitor Sildenafil was several-fold more powerful in relaxing the HF/LF MA1s, and pre-treatment with Sildenafil uncovered an increased responsiveness of HF/LF MA1s to the NO donor DEA/NO. We conclude that induction of PDE5 de-sensitizes this systemic resistance artery to sustained NO signaling under chronic HF/LF. Treatment with PDE5 antagonists, in contrast to NO donors, may more specifically and effectively increase blood flow to chronically hypo-perfused tissues. PMID:19374906

  15. Effects of Low-Load, Elastic Band Resistance Training Combined With Blood Flow Restriction on Muscle Size and Arterial Stiffness in Older Adults.

    Science.gov (United States)

    Yasuda, Tomohiro; Fukumura, Kazuya; Uchida, Yusuke; Koshi, Hitomi; Iida, Haruko; Masamune, Ken; Yamasoba, Tatsuya; Sato, Yoshiaki; Nakajima, Toshiaki

    2015-08-01

    We examined the effect of low-load, elastic band resistance training with blood flow restriction (BFR) on muscle size and arterial stiffness in older adults. Healthy older adults (aged 61-85 years) were divided into BFR training (BFR-T, n = 9) or non-BFR training (CON-T, n = 8) groups. Both groups performed low-load arm curl and triceps down exercises (four sets, total 75 repetitions for each) using an elastic band, 2 d/wk for 12 weeks. The BFR-T group wore inflated pneumatic elastic cuffs (120-270 mm Hg) on both arms during training. Magnetic resonance imaging-measured muscle cross-sectional area of the upper arm, maximum voluntary isometric contraction of the elbow flexors and extensors, cardio-ankle vascular index testing, and ankle-brachial pressure index were measured before and 3-5 days after the final training session. Muscle cross-sectional area of the elbow flexors (17.6%) and extensors (17.4%) increased, as did elbow flexion and elbow extension maximum voluntary isometric contraction (7.8% and 16.1%, respectively) improved (p ankle vascular index and ankle-brachial pressure index testing, there were no changes between pre- and post-results in either group. In conclusion, elastic band BFR-T improves muscle cross-sectional area as well as maximal muscle strength but does not negatively affect arterial stiffness in older adults. PMID:24917178

  16. Can cerebral blood flow measurement predict clinical outcome in the acute phase in patients with artherosclerotic occlusive carotid artery disease?

    International Nuclear Information System (INIS)

    It has been thought that the clinical course of patients with acute carotid occlusive disease depends on their collateral cerebral blood flow (CBF) and duration of ischemia. However, there have been few clinical reports to prove this hypothesis. Therefore, we performed CBF study in patients with artherosclerotic carotid occlusive disease in the very acute phase, and precisely assessed the prognosis of those patients under intensive medical therapy. This prospective study included a total of 44 patients (72±13 years) who were admitted to our hospital between April, 2007 and December, 2008. To evaluate their initial CBF, single photon emission computed tomography (SPECT) studies were performed within 6 hours after the onset. All patients included in this study were medically treated and were periodically followed up by neurological and radiological examination. Moreover, in patients with reduced CBF (ipsilateral CBF/contralateral CBF x 100: %CBF <80%), dobutamine-induce hyperdynamic therapy was performed. Multivariate analysis was performed to detect significant predictors for the occurrence of further cerebral infarction. Multivariate analysis showed that the occurrence of further infarction was associated with older age and smaller %CBF. Of 44 patients, 21 experienced further cerebral infarction within 10 days after onset. Fourteen out of 15 patients with %CBF <60% developed cerebral infarction. This study showed that the prognosis of the patients with artherosclerotic carotid occlusive disease in the acute phase is associated with their initial residual CBFs. It may be difficult to stop the developed cerebral infarction in those patients with %CBF <60% despite intensive medical therapy. (author)

  17. Novel chemoradiotherapy for locally advanced pancreatic cancer using arterial infusion chemotherapy following the alteration of peripancreatic blood flow

    International Nuclear Information System (INIS)

    Radiotherapy employing intraoperative radiation therapy (IORT) in combination with postoperative external beam radiation therapy (EBRT) is an effective treatment for unresectable pancreatic cancer. To achieve an even greater therapeutic outcome, 13 patients with unresectable pancreatic cancer were treated by IORT in combination with EBRT plus locally intensive arterial infusion chemotherapy. In order to increase drug delivery to the primary tumor, the splenic and major pancreatic arteries, except for the gastroduodenal artery (GDA), were embolized by radiological intervention prior to the arterial infusion chemotherapy, and the administration of gemcitabine, cisplatin, and 5-fluorouracil to the primary tumors via GDA was followed during EBRT. The values of serum tumor markers were decreased in all patients, and tumor regression was detected on CT scans in 6 patients. The evaluation of survival benefit of this treatment modality is ongoing, but it did not prolong the survival time of patients with second stage lymph node metastases. One of the advantages of this method was able to perform also in charge of hepatic arterial infusion chemotherapy concurrently, but we experienced liver abscess in 2 patients. (author)

  18. Effect of antihistamines, disodium cromoglycate (DSCG) or methysergide on post-irradiation cerebral blood flow and mean systemic arterial blood pressure in primates after 25 Gy, whole-body, gamma irradiation

    International Nuclear Information System (INIS)

    Exposure to ionizing radiation causes hypotension, cerebral ischemia and release of histamine (HA) and serotonin (5-HT). To investigate the relationship among these responses, rhesus monkeys (Macaca mulatta) received physiological saline (i.v.), disodium cromoglycate (DSCG), antihistamines (AH, mepyramine and cimetidine), or methysergide (METH), then were given 25 Gy whole-body irradiation. Monkeys receiving DSCG, AH or METH had higher post-irradiation mean arterial blood pressure (MBP) than saline-treated controls. Compared to levels in controls, post-irradiation hippocampal blood flow (rCBF) levels were higher in monkeys receiving DSCG, AH or METH. Treatment with the 5-HT2 receptor antagonist methysergide was the most effective in maintaining both rCBF and MBP after irradiation. Results support the hypothesis that the irradiation-induced cerebral ischemia and, to some extent, the hypotension is mediated by serotonin through 5-HT2 receptor sites. (author) 72 refs

  19. Effect of antihistamines, disodium cromoglycate (DSCG) or methysergide on post-irradiation cerebral blood flow and mean systemic arterial blood pressure in primates after 25 Gy, whole-body, gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Cockerham, L.G.; Forcino, C.D. [Armed Forces Radiobiology Research Inst., Bethesda, MD (United States)

    1995-06-01

    Exposure to ionizing radiation causes hypotension, cerebral ischemia and release of histamine (HA) and serotonin (5-HT). To investigate the relationship among these responses, rhesus monkeys (Macaca mulatta) received physiological saline (i.v.), disodium cromoglycate (DSCG), antihistamines (AH, mepyramine and cimetidine), or methysergide (METH), then were given 25 Gy whole-body irradiation. Monkeys receiving DSCG, AH or METH had higher post-irradiation mean arterial blood pressure (MBP) than saline-treated controls. Compared to levels in controls, post-irradiation hippocampal blood flow (rCBF) levels were higher in monkeys receiving DSCG, AH or METH. Treatment with the 5-HT{sub 2} receptor antagonist methysergide was the most effective in maintaining both rCBF and MBP after irradiation. Results support the hypothesis that the irradiation-induced cerebral ischemia and, to some extent, the hypotension is mediated by serotonin through 5-HT{sub 2} receptor sites. (author) 72 refs.

  20. Defining the residual risk of adverse perinatal outcome in growth restricted fetuses with normal umbilical artery blood flow.

    LENUS (Irish Health Repository)

    O'Dwyer, Vicky

    2014-07-25

    To determine the cause of adverse perinatal outcome in fetal growth restriction(FGR) where umbilical artery Doppler(UA) was normal, as identified from the Prospective Observational Trial to Optimize Pediatric Health(PORTO). We compared cases of adverse outcome where UA Doppler was normal and abnormal.

  1. ROLE OF COLOUR DOPPLER: CEREBRAL AND UMBILICAL ARTERIAL BLOOD FLOW VELOCITY IN NORMAL AND GROWTH RESTRICTED PREGNANCY

    Directory of Open Access Journals (Sweden)

    Patange

    2014-03-01

    Full Text Available INTRODUCTION: Doppler velocimetry is a rapid noninvasive test that provides valuable information about haemodynamic situation of the foetus and is an efficient diagnostic test of foetal jeopardy which helps in timely intervention and management of high risk pregnancy for better perinatal outcome. OBJECTIVES: To evaluate middle cerebral artery and umbilical arterial velocity waveforms and their various indices during third trimester of pregnancy. METHODOLOGY: Prospective study including 50 women with normal singleton pregnancy and 50 women with intrauterine growth restricted pregnancy booked for regular antenatal checkups in our hospital. RESULTS: Foetal biometery i. e. EFW(estimated foetal weight , BPD (bi parietal diameter, HC(head circumference, AC(abdominal circumference and FL( femur length all the values were significantly reduced in IUGR pregnancy. Mean amniotic fluid index was significantly reduced for IUGR pregnancy. Umbilical artery indices were significantly raised in IUGR pregnancy. Mean Pulsatility index (PI for study group was 1.03±0.22 as compared to control group of 0.87±0.17, P value being < 0.0003. Mean Resistance index (RI for study group was 0.65±0.14 as compared to 0.58±0.06 for control group, P value being 0.0015. Mean Systolic diastolic ratio (S/D for study group was 2.96±0.78 as compared to 2.43±0.32 for control group, P value being < 0.0001. Reduced mean middle cerebral artery indices in IUGR pregnancy. Cerebro umbilical ratio was significantly reduced in study group. AEDV was present in 12% of women in study group and REDV in 8% women of study group. IUGR pregnancies deliver early as in comparison to normal pregnancies. Significant numbers of babies having IUGR were delivery by LSCS. Mean birth weight is significantly reduced in control for study group. Similarly, significant number of babies in IUGR pregnancies requires NICU admission .Significant number of patients in study group has associated PIH. CONCLUSIONS

  2. Blood flow velocity in migraine attacks - a transcranial Doppler study

    Energy Technology Data Exchange (ETDEWEB)

    Zwetsloot, C.P.; Caekebeke, J.F.V.; Jansen, J.C.; Odink, J.; Ferrari, M.D. (Rijksuniversiteit Leiden (Netherlands))

    1991-05-01

    A pulsed Doppler device was used to measure blood flow velocities in the common carotid artery, the extracranial part of the internal carotid artery, the external carotid artery, the middle cerebral artery, and the anterior cerebral artery in 31 migraneurs without aura (n=27) and with aura (n=4), both during and ouside an attack. The aims were to compare blood flow velocity during and between migraine attacks and to study asymmetries of the blood flow velocity. Compared with blood flow velocity values obtained in the attack-free interval, blood flow velocity was lower during attacks without aura in both common carotid arteries, but not in the other extra- and intracranial vessels which were examined. However, during attacks of migraine with aura, blood flow velocity tended to be lower in all examined vessels. There were no asymmetries of the blood flow velocity. It is suggested that during migraine attacks without aura there is a dissociation in blood flow regulation in the common carotid and middle cerebral arteries. 20 refs., 2 tabs.

  3. Blood flow velocity in migraine attacks - a transcranial Doppler study

    International Nuclear Information System (INIS)

    A pulsed Doppler device was used to measure blood flow velocities in the common carotid artery, the extracranial part of the internal carotid artery, the external carotid artery, the middle cerebral artery, and the anterior cerebral artery in 31 migraneurs without aura (n=27) and with aura (n=4), both during and ouside an attack. The aims were to compare blood flow velocity during and between migraine attacks and to study asymmetries of the blood flow velocity. Compared with blood flow velocity values obtained in the attack-free interval, blood flow velocity was lower during attacks without aura in both common carotid arteries, but not in the other extra- and intracranial vessels which were examined. However, during attacks of migraine with aura, blood flow velocity tended to be lower in all examined vessels. There were no asymmetries of the blood flow velocity. It is suggested that during migraine attacks without aura there is a dissociation in blood flow regulation in the common carotid and middle cerebral arteries. 20 refs., 2 tabs

  4. Blood Flow Multiscale Phenomena

    OpenAIRE

    Agić, Ante; Mijović, Budimir; Nikolić, Tatjana

    2007-01-01

    The cardiovascular disease is one of most frequent cause deaths in modern society. The objective of this work is analyse the effect of dynamic vascular geometry (curvature, torsion,bifurcation) and pulsatile blood nature on secondary flow, wall shear stress and platelet deposition. The problem was examined as multi-scale physical phenomena using perturbation analysis and numerical modelling. The secondary flow determined as influence pulsatile pressure, vascular tube time-dependen...

  5. Effects of Sustained Low-Level Elevations of Carbon Dioxide on Cerebral Blood Flow and Autoregulation of the Intracerebral Arteries in Humans

    Science.gov (United States)

    Sliwka, U.; Krasney, J. A.; Simon, S. G.; Schmidt, P.

    1996-01-01

    Cerebral blood flow velocity (CBFv) was measured by insonating the middle cerebral arteries of 4 subjects using a 2 Mhz transcranial Doppler. Ambient CO2 was elevated to 0.7% for 23 days in the first study and to 1.2% for 23 days in the same subjects in the second study. By non-parametric testing CBFv was elevated significantly by +35% above pre-exposure levels during the first 1-3 days at both exposure levels after which CBFv progressively readjusted to pre-exposure levels. Despite similar CBFv responses, headache was only reported during the initial phase of exposure to 1.2% CO2. Vascular reactivity to CO2 assessed by rebreathing showed a similar pattern with the CBFv increases early in the exposures being greater than those elicited later. An increase in metabolic rate of the visual cortex was evoked by having the subjects open and close their eyes during a visual stimulus. Evoked CBFv responses measured in the posterior cerebral artery were also elevated in the first 1-3 days of both studies returning to pre-exposure levels as hypercapnia continued. Cerebral vascular autoregulation assessed by raising head pressure during 10 deg head-down tilt both during the low-level exposures and during rebreathing was unaltered. There were no changes in the retinal microcirculation during serial fundoscopy studies. The time-dependent changes in CO2 vascular reactivity might be due either to retention of bicarbonate in brain extracellular fluid or to progressive increases in ventilation, or both. Cerebral vascular autoregulation appears preserved during chronic exposure to these levels of ambient CO2.

  6. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H;

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven t...... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  7. Non invasive tomographic imaging of cerebral blood flow (CBF) and oxygen extraction fraction (OEF) in superficial temporal artery to middle cerebral artery (STA-MCA) anastomosis

    International Nuclear Information System (INIS)

    Clinical indications for extra-intracranial arterial bypass (EIAB) surgery are still rather ill-defined and are the matter of a randomized trial in progress currently. However, 'hemodynamic' transient ischemic attacks (TIAs) are considered at present the clinical entity that should benefit most from this surgical procedure. The contribution of conventional CBF techniques in assessing both the physiological indications and the usefulness of EIAB has been only moderate, though substantial. Clearly, both CBF and regional metabolic data should be obtained, ideally in tomographic representation. We have attempted such study using the 15O continuous inhalation technique in a small number of instructive patients. Two different patterns of the CBF-OEF relationship have been defined that could be of some importance in respect to both the underlying mechanisms of 'hemodynamic' TIAs and to the rational bases for EIAB procedures

  8. Measurement of aortic blood flow by magnetic resonance below and above the origin of the coronary arteries in postmenopausal hormone replacement therapy

    DEFF Research Database (Denmark)

    Sørensen, Morten Beck; Fritz-Hansen, Thomas; Jensen, Henrik Halvor;

    2004-01-01

    PURPOSE: Principal blood flow measures might be assessable by velocity-encoded cine magnetic resonance (VENC MR) of aortic blood flow. The feasibility of using VENC MR for clinical research was tested in a contemporary and controversial human model: the effects of 17beta-estradiol (E) and cyclic...

  9. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases

    International Nuclear Information System (INIS)

    Purpose: The aim of the study is to find out whether the measurement of peak systolic velocity in the inferior thyroid artery (ITA) is a valuable parameter to differentiate autoimmune thyroid diseases (hyper-, normo- or hypofunctional) and to evaluate the efficacy of medical treatment. Material and methods: The ITA of 31 patients (eight with Graves' disease, 23 with subclinical hypothyroidism) was examined with color Doppler and pulsed Doppler. The final diagnosis was obtained by citology and by hormonal and antibodies assays. The patients were monitorized by ultrasound for a period of 8 months. Results: In all the patients with Graves' disease the peak systolic velocity was always over 150 cm/s, while in other autoimmune thyroiditis the peak systolic velocity was within the normal range, and never exceeding 65 cm/s. In the first group, the measurement taken in the ITA showed also the efficacy of the pharmacological treatment earlier and more reliably than the color Doppler pattern obtained in the parenchyma. Conclusions: The color Doppler measurement of the ITA seems to be a promising technique with low-cost and easy approach. In our experience, the color Doppler of the ITA could have a clinical role in the differential diagnosis of diffuse thyroid diseases and in the follow-up of the Graves' disease during medical treatment

  10. Effectiveness of a New Exercise Program after Lower Limb Arterial Blood Flow Surgery in Patients with Peripheral Arterial Disease: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Edita Jakubsevičienė

    2014-08-01

    Full Text Available Objective: The aim of this study was to evaluate the effectiveness of a supervised exercise program (SEP plus at home nonsupervised exercise therapy (non-SET on functional status, quality of life (QoL and hemodynamic response in post-lower-limb bypass surgery patients. Results: One hundred and seventeen patients were randomized to an intervention (n = 57 or a control group (n = 60. A new individual SEP was designed for patients with peripheral arterial disease (PAD and applied to the studied subjects of the intervention group who also continued non-SET at home, whereas those assigned to the control group received just usual SEP according to a common cardiovascular program. The participants of the study were assessed by a 6-min walking test (6 MWT, an ankle-brachial index (ABI, and the Medical Outcomes Study Short Form-36 (SF-36 of QoL at baseline, at 1 and 6 months after surgery. A significant improvement was observed in the walked distance in the intervention group after 6 months compared with the control group (p < 0.001. The intervention group had significantly higher QoL score in the physical and mental component of SF-36 (p < 0.05. Conclusions: A 6-month application of the new SEP and non-SET at home has yielded significantly better results in walking distance and QoL in the intervention group than in the controls.

  11. A Discussion on the Regulation of Blood Flow and Pressure.

    Science.gov (United States)

    Wolff, Christopher B; Collier, David J; Shah, Mussadiq; Saxena, Manish; Brier, Timothy J; Kapil, Vikas; Green, David; Lobo, Melvin

    2016-01-01

    This paper discusses two kinds of regulation essential to the circulatory system: namely the regulation of blood flow and that of (systemic) arterial blood pressure. It is pointed out that blood flow requirements sub-serve the nutritional needs of the tissues, adequately catered for by keeping blood flow sufficient for the individual oxygen needs. Individual tissue oxygen requirements vary between tissue types, while highly specific for a given individual tissue. Hence, blood flows are distributed between multiple tissues, each with a specific optimum relationship between the rate of oxygen delivery (DO2) and oxygen consumption (VO2). Previous work has illustrated that the individual tissue blood flows are adjusted proportionately, where there are variations in metabolic rate and where arterial oxygen content (CaO2) varies. While arterial blood pressure is essential for the provision of a sufficient pressure gradient to drive blood flow, it is applicable throughout the arterial system at any one time. Furthermore, It is regulated independently of the input resistance to individual tissues (local arterioles), since they are regulated locally, that being the means by which the highly specific adequate local requirement for DO2 is ensured. Since total blood flow is the summation of all the individually regulated tissue blood flows cardiac inflow (venous return) amounts to total tissue blood flow and as the heart puts out what it receives cardiac output is therefore determined at the tissues. Hence, regulation of arterial blood pressure is independent of the distributed independent regulation of individual tissues. It is proposed here that mechanical features of arterial blood pressure regulation will depend rather on the balance between blood volume and venous wall tension, determinants of venous pressure. The potential for this explanation is treated in some detail. PMID:26782204

  12. Cerebral blood flow velocity changes after rapid administration of surfactant.

    OpenAIRE

    Cowan, F.; Whitelaw, A; D. Wertheim; Silverman, M

    1991-01-01

    A computer linked Doppler system was used to make continuous measurements of cerebral blood flow velocity (CBFV) from the middle cerebral artery, mean arterial blood pressure (MAP) from the umbilical artery, and heart rate before, during, and for 20 minutes after the endotracheal administration of 200 mg/kg of porcine surfactant in 10 preterm infants with respiratory distress syndrome. Within two minutes of surfactant administration, there was a median fall of 6 mm Hg (15%) fall in MAP and 36...

  13. Assessment of tumor blood flow and its correlation with histopathologic features in skull base meningiomas and schwannomas by using pseudo-continuous arterial spin labeling images

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tatsuya, E-mail: yamatatu_01eik@yahoo.co.jp [Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui (Japan); Takeuchi, Hiroaki, E-mail: takeu@u-fukui.ac.jp [Department of Neurosurgery, Faculty of Medical Sciences, University of Fukui, Fukui (Japan); Kinoshita, Kazuyuki, E-mail: kkino@u-fukui.ac.jp [Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui (Japan); Kosaka, Nobuyuki, E-mail: nkosaka@u-fukui.ac.jp [Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui (Japan); Kimura, Hirohiko, E-mail: kimura@u-fukui.ac.jp [Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui (Japan)

    2014-05-15

    Objective: We aimed to investigate whether pseudo-continuous arterial spin labeling (pcASL)-MRI can adequately evaluate tumor perfusion even if the tumors are located in the skull base region and evaluate the correlation between tumor blood flow (TBF) and the histopathologic features of skull base meningiomas and schwannomas. Materials and methods: We enrolled 31 patients with skull base meningioma (n = 14) and schwannoma (n = 17) who underwent surgical resection. TBF was calculated from pcASL. Tissue sections were stained with CD34 to evaluate microvessel area (MVA). TBF and MVA ratio were compared between meningiomas and schwannomas using Mann–Whitney U-test. The correlations between MVA ratio and TBF were evaluated in each tumor by using single linear regression analysis and Spearman's rank correlation coefficients (r{sub s}). Results: MVA ratio and TBF were significantly higher in meningioma than in schwannoma (both p < 0.01). Correlation analyses revealed significant positive correlations between MVA ratio and both mean and max TBF for meningiomas (r{sub s} = 0.89, 0.81, both p < 0.01). There was a weak positive correlation between MVA ratio and mean TBF for schwannomas (r{sub s} = 0.43, p = 0.04). However, no significant correlation was found between MVA ratio and max TBF for schwannoma. Conclusions: pcASL-MRI is useful for evaluating tumor perfusion even if the tumors are located in the skull base region. Moreover, pcASL-TBF was significantly higher in most meningiomas compared to schwannomas, which can help in the differential diagnosis of the 2 tumor types even without the use of contrast material.

  14. Changes in cerebral blood flow after transjugular intrahepatic portosystemic shunt can help predict the development of hepatic encephalopathy: An arterial spin labeling MR study

    International Nuclear Information System (INIS)

    Background and purpose: Cerebral blood flow (CBF) changes after transjugular intrahepatic portosystemic shunt (TIPS) are still unclear. Our aim is to assess the TIPS-induced CBF changes and their potential clinical significance using the arterial spin labeling (ASL) perfusion magnetic resonance imaging. Materials and methods: Nine cirrhotic patients underwent ASL 1–8 days before and 4–7 days after TIPS. CBF was calculated at each voxel and mean CBF values were computed in the whole brain, gray matter and white matter. Changes of CBFs before and after TIPS were compared by paired t-test. Results: Voxel-wise results showed CBF diffusely increased in patients after TIPS, but no region with significant decrease in CBF was found, nor was any significant mean CBF difference detected in the whole brain, gray matter and white matter. Six patients out of nine showed a global CBF increase of 9–39%; one patient presented a global CBF decrease of 6%; another two showed a global CBF decrease of 16% and 31% respectively. Follow-up studies showed that the two patients with greatly decreased global CBF suffered from multiple episodes of overt hepatic encephalopathy (OHE) after TIPS and one died of OHE. Conclusions: CBF derived from noninvasive ASL MRI could be used as a useful biomarker to predict the development of OHE through consecutively tracking CBF changes in patients with inserted TIPS. Increased CBFs in many cortical regions could be common effects of the TIPS procedure, while decreased global CBF following TIPS might indicate the development of OHE.

  15. Cerebral blood flow measured by arterial-spin labeling MRI: A useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis

    International Nuclear Information System (INIS)

    Purpose: To investigate the role of arterial-spin labeling (ASL) MRI to non-invasively characterize the patterns of cerebral blood flow (CBF) changes in cirrhotic patients and to assess the potential of ASL MRI to characterize minimal hepatic encephalopathy (MHE). Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Thirty six cirrhosis patients without overt hepatic encephalopathy (16 MHE patients and 20 non hepatic encephalopathy (non-HE) patients) and 25 controls underwent ASL MRI, and CBF was measured for each subject. One-way ANOCOVA test with age and gender as covariences was used to compare CBF difference among three groups, and post hoc analysis was performed between each two groups. Region-based correlation analysis was applied between Child–Pugh score, venous blood ammonia level, neuropsychological tests and CBF values in cirrhosis patients. Receiver operator characteristic (ROC) analysis was used for assessing CBF measurements in ASL MRI to differentiate MHE from non-HE patients. Results: The gray matter CBF of MHE patients (71.09 ± 11.88 mL min−1 100 g−1) was significantly higher than that of non-HE patients (55.28 ± 12.30 mL min−1 100 g−1, P < 0.01) and controls (52.09 ± 9.27 mL min−1 100 g−1, P < 0.001). Voxel-wise ANOCOVA results showed that CBFs were significantly different among three groups in multiple gray matter areas (P < 0.05, Bonferroni corrected). Post hoc comparisons showed that CBF of these brain regions was increased in MHE patients compared with controls and non-HE patients (P < 0.05, Bonferroni corrected). CBF of the right putamen was of the highest sensitivity (93.8%) and moderate specificity (75.0%) for characterization of MHE when using the cutoff value of 50.57 mL min−1 100 g−1. CBFs in the bilateral median cingulate gyri, left supramarginal gyrus, right angular gyrus, right heschl gyrus and right superior temporal gyrus

  16. Cerebral blood flow measured by arterial-spin labeling MRI: A useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Gang [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu, 210016 (China); Zhang, Long Jiang, E-mail: kevinzhlj@163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Zhong, Jianhui [Department of Imaging Sciences, University of Rochester School of Medicine and Dentistry, Box648, 601 Elmwood Avenue, Rochester, NY 14642-8648 (United States); Wang, Ze [Department of Psychiatry, Perelman School of Medicine, University of Pennsylvania, 3900 Chestnut St., Philadelphia, PA 19104 (United States); Qi, Rongfeng; Shi, Donghong [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Lu, Guang Ming, E-mail: cjr.luguangming@vip.163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China)

    2013-11-01

    Purpose: To investigate the role of arterial-spin labeling (ASL) MRI to non-invasively characterize the patterns of cerebral blood flow (CBF) changes in cirrhotic patients and to assess the potential of ASL MRI to characterize minimal hepatic encephalopathy (MHE). Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Thirty six cirrhosis patients without overt hepatic encephalopathy (16 MHE patients and 20 non hepatic encephalopathy (non-HE) patients) and 25 controls underwent ASL MRI, and CBF was measured for each subject. One-way ANOCOVA test with age and gender as covariences was used to compare CBF difference among three groups, and post hoc analysis was performed between each two groups. Region-based correlation analysis was applied between Child–Pugh score, venous blood ammonia level, neuropsychological tests and CBF values in cirrhosis patients. Receiver operator characteristic (ROC) analysis was used for assessing CBF measurements in ASL MRI to differentiate MHE from non-HE patients. Results: The gray matter CBF of MHE patients (71.09 ± 11.88 mL min{sup −1} 100 g{sup −1}) was significantly higher than that of non-HE patients (55.28 ± 12.30 mL min{sup −1} 100 g{sup −1}, P < 0.01) and controls (52.09 ± 9.27 mL min{sup −1} 100 g{sup −1}, P < 0.001). Voxel-wise ANOCOVA results showed that CBFs were significantly different among three groups in multiple gray matter areas (P < 0.05, Bonferroni corrected). Post hoc comparisons showed that CBF of these brain regions was increased in MHE patients compared with controls and non-HE patients (P < 0.05, Bonferroni corrected). CBF of the right putamen was of the highest sensitivity (93.8%) and moderate specificity (75.0%) for characterization of MHE when using the cutoff value of 50.57 mL min{sup −1} 100 g{sup −1}. CBFs in the bilateral median cingulate gyri, left supramarginal gyrus, right angular gyrus, right

  17. Coronary blood flow in the anesthetized American alligator (Alligator mississippiensis).

    Science.gov (United States)

    Jensen, Bjarke; Elfwing, Magnus; Elsey, Ruth M; Wang, Tobias; Crossley, Dane A

    2016-01-01

    Coronary circulation of the heart evolved early within ectothermic vertebrates and became of vital importance to cardiac performance in some teleost fish, mammals and birds. In contrast, the role and function of the coronary circulation in ectothermic reptiles remains largely unknown. Here, we investigated the systemic and coronary arterial responses of five anesthetized juvenile American alligators (Alligator mississippiensis) to hypoxia, acetylcholine, adenosine, sodium nitroprusside, isoproterenol, and phenylephrine. We recorded electrocardiograms, monitored systemic blood pressure, blood flows in both aortae, and blood flow in a major coronary artery supplying most of the right ventricle. Coronary arterial blood flow was generally forward, but there was a brief retrograde flow during a ventricular contraction. Blood pressure was significantly changed in all conditions. Acetylcholine decreased coronary forward flow, but this response was confounded by the concomitant lowered work of the ventricles due to decreased heart rate and blood pressure. Coronary forward flow was poorly correlated with heart rate and mean arterial pressure across treatments. Overall changes in coronary forward flow, significant and not significant, were generally in the same direction as mean arterial pressure and ventricular power, approximated as the product of systemic cardiac output and mean arterial pressure. PMID:26436857

  18. Spiral blood flow in aorta-renal bifurcation models.

    Science.gov (United States)

    Javadzadegan, Ashkan; Simmons, Anne; Barber, Tracie

    2016-07-01

    The presence of a spiral arterial blood flow pattern in humans has been widely accepted. It is believed that this spiral component of the blood flow alters arterial haemodynamics in both positive and negative ways. The purpose of this study was to determine the effect of spiral flow on haemodynamic changes in aorta-renal bifurcations. In this regard, a computational fluid dynamics analysis of pulsatile blood flow was performed in two idealised models of aorta-renal bifurcations with and without flow diverter. The results show that the spirality effect causes a substantial variation in blood velocity distribution, while causing only slight changes in fluid shear stress patterns. The dominant observed effect of spiral flow is on turbulent kinetic energy and flow recirculation zones. As spiral flow intensity increases, the rate of turbulent kinetic energy production decreases, reducing the region of potential damage to red blood cells and endothelial cells. Furthermore, the recirculation zones which form on the cranial sides of the aorta and renal artery shrink in size in the presence of spirality effect; this may lower the rate of atherosclerosis development and progression in the aorta-renal bifurcation. These results indicate that the spiral nature of blood flow has atheroprotective effects in renal arteries and should be taken into consideration in analyses of the aorta and renal arteries. PMID:26414530

  19. Regional cerebral blood flow in focal cortical epilepsy

    DEFF Research Database (Denmark)

    Hougaard, Kristina Dupont; Oikawa, T; Sveinsdottir, E;

    1976-01-01

    Regional cerebral blood flow (rCBF) was studied in ten patients with focal cortical epilepsy. The blood flow was measured by the intra-arterial injection of xenon 133 (133Xe), and the isotope clearance was recorded by a multidetector scintillation camera with 254 detectors. Three patients were...

  20. Collateral sources of costal and crural diaphragmatic blood flow

    International Nuclear Information System (INIS)

    We measured the contribution of aortic, internal mammary, and intercostal arteries to the blood flow to the costal and crural segments of the diaphragm and other respiratory muscles in seven dogs breathing against a fixed inspiratory elastic load. We used radiolabeled microspheres to measure the blood flow with control circulation, occlusion of the aorta distal to the left subclavian artery, combined occlusion of the aorta and both internal mammary arteries, and occlusion of internal mammary arteries alone. With occlusion of the aorta distal to the left subclavian artery, blood flow to the crural diaphragm decreased from 40.3 to 23.5 ml . min-1 X 100 g-1, whereas costal flow did not change significantly (from 41.7 to 38.1 ml . min-1 . 100 g-1). Blood flows to the sternomastoid and scalene muscles (above the occlusion) increased by 200 and 340%, respectively, whereas flows to the other respiratory muscles did not change significantly. Blood flows to organs above the occlusion either remained unchanged or increased, whereas flows to those below the occlusion all decreased. When the internal mammary artery was also occluded, flows to the crural segment decreased further to 12.1 and costal flow decreased to 20.4 ml X min-1 X 100 g-1. Internal mammary arterial occlusion alone in two dogs had no effect on diaphragmatic flow. In conclusion, intercostal collateral vessels are capable of supplying a significant proportion of blood flow to both segments of the diaphragm but the costal segment is better served than the crural segment

  1. Coronary risk factors and myocardial blood flow in patients evaluated for coronary artery disease: a quantitative [15O]H2O PET/CT study

    International Nuclear Information System (INIS)

    There has been increasing interest in quantitative myocardial blood flow (MBF) imaging over the last years and it is expected to become a routinely used technique in clinical practice. Positron emission tomography (PET) using [15O]H2O is the established gold standard for quantification of MBF in vivo. A fundamental issue when performing quantitative MBF imaging is to define the limits of MBF in a clinically suitable population. The aims of the present study were to determine the limits of MBF and to determine the relationship among coronary artery disease (CAD) risk factors, gender and MBF in a predominantly symptomatic patient cohort without significant CAD. A total of 128 patients (mean age 54 ± 10 years, 50 men) with a low to intermediate pretest likelihood of CAD were referred for noninvasive evaluation of CAD using a hybrid PET/computed tomography (PET/CT) scanner. MBF was quantified with [15O]H2O at rest and during adenosine-induced hyperaemia. Obstructive CAD was excluded in these patients by means of invasive or CT-based coronary angiography. Global average baseline MBF values were 0.91 ± 0.34 and 1.09 ± 0.30 ml.min-1.g-1 (range 0.54-2.35 and 0.59-2.75 ml.min-1.g-1) in men and women, respectively (p -1.g-1 in men and women, respectively; p = 0.08). Global average hyperaemic MBF values were 3.44 ± 1.20 ml.min-1.g-1 in the whole study population, and 2.90 ± 0.85 and 3.78 ± 1.27 ml.min-1.g-1 (range 1.52-5.22 and 1.72-8.15 ml.min-1.g-1) in men and women, respectively (p < 0.001). Multivariate analysis identified male gender, age and body mass index as having an independently negative impact on hyperaemic MBF. Gender, age and body mass index substantially influence reference values and should be corrected for when interpreting hyperaemic MBF values. (orig.)

  2. Amlodipine induces a flow and pressure-independent vasoactive effect on the brachial artery in hypertension.

    OpenAIRE

    Megnien, J L; Levenson, J.; Del-Pino, M; Simon, A

    1995-01-01

    1. The objectives of this study were to study the flow-dependent arterial reactivity and pressure-independent arterial compliance of the calcium antagonist amlodipine in hypertensive men. 2. Twenty-one hypertensive patients were randomized to receive 2 months treatment with placebo (n = 10) or 5-10 mg amlodipine (n = 11) once a day. Non-invasive measurement of brachial artery mean blood pressure, diameter and flow (pulsed Doppler) and compliance (arterial mechanography and logarithmic elastic...

  3. Positron emission tomography/magnetic resonance hybrid scanner imaging of cerebral blood flow using 15O-water positron emission tomography and arterial spin labeling magnetic resonance imaging in newborn piglets

    DEFF Research Database (Denmark)

    Andersen, Julie B; Henning, William S; Lindberg, Ulrich;

    2015-01-01

    arterial spin labeling (ASL) magnetic resonance imaging (MR) on a hybrid PET/MR in seven newborn piglets. Positron emission tomography was performed with IV injections of 20 MBq and 100 MBq (15)O-water to confirm CBF reliability at low activity. Cerebral blood flow was quantified using a one-tissue-compartment-model......Abnormality in cerebral blood flow (CBF) distribution can lead to hypoxic-ischemic cerebral damage in newborn infants. The aim of the study was to investigate minimally invasive approaches to measure CBF by comparing simultaneous (15)O-water positron emission tomography (PET) and single TI pulsed......, PET-IDIF overestimated CBF. Injected activity of 20 MBq (15)O-water had acceptable concordance with 100 MBq, without compromising image quality. Single TI ASL was questionable for regional CBF measurements. Global ASL CBF and PET CBF were congruent during baseline but not during hyperperfusion....

  4. Gastric mucosal blood flow measurement

    International Nuclear Information System (INIS)

    Pertechnetate clearance (C/sub Tc/) by the stomach before and after betazole stimulation was compared to regional measurements of gastric blood flow utilizing nuclide (Chromium-51 and Cerium-141)-labeled microspheres in five piglets. Pertechnetate clearance closely correlated (correlation coefficient 0.926) with mucosal blood flow in the gastric corpus measured by the microsphere technique. Betazole increased blood flow in the corpus region by 100 percent but did not alter this relationship. Except in one experiment, microsphere blood flow valves in the antrum and fundus were unchanged by betazole and did not significantly correlate with pertechnetate clearance. Pertechnetate clearance appears to be a reliable method of determining gastric mucosal blood flow in experimental animals and may be considered as a noninvasive method for measuring such flow in humans. (U.S.)

  5. Arterial Blood, Rather Than Venous Blood, is a Better Source for Circulating Melanoma Cells

    Directory of Open Access Journals (Sweden)

    Mizue Terai

    2015-11-01

    Interpretation: Our data indicate that arterial blood specimens might be a better source of circulating uveal melanoma cells. Although less conveniently processed, perhaps arterial blood should be evaluated as sample source for measurement of CTCs.

  6. Blood serum atherogenicity and coronary artery calcification.

    Science.gov (United States)

    Sobenin, Igor A; Myasoedova, Veronica A; Anisimova, Elena V; Pavlova, Xenia N; Möhlenkamp, Stefan; Schmermund, Axel; Seibel, Rainer; Berenbein, Sina; Lehmann, Nils; Moebus, Susanne; Jöckel, KarlHeinz; Orekhov, Alexander N; Erbel, Raimund

    2014-01-01

    The phenomenon of blood serum atherogenicity was described as the ability of human serum to induce lipid accumulation in cultured cells. The results of recent two-year prospective study in asymptomatic men provided the evidence for association between the changes in serum atherogenicity and dynamics of carotid intima-media thickness progression. The present study was undertaken to test the hypothesis that blood serum atherogenicity and its changes in dynamics may be associated with accumulation of coronary calcium in subclinical atherosclerosis. It was performed in 782 CHD-free participants of The Heinz Nixdorf RECALL (Risk Factors, Evaluation of Coronary Calcium and Lifestyle) Study, in whom blood samples have been taken at the baseline and at the end of 5-year follow-up. Opposite to the previous findings, the changes in serum atherogenicity did not correlate neither with the extent of coronary artery calcification, nor with the changes in Agatston CAC score. There was a moderate but significant rise in serum atherogenicity after 5-year followup period, and the same dynamics was observed for Agatston CAC score, but not for convenient lipid-related risk factors. The absence of association of the changes in serum atherogenicity with the changes in Agatston CAC score, along with previous findings, provides a point of view that serum-induced intracellular cholesterol accumulation is not related to the processes of calcium deposition in arterial wall, since the last one reflects the progression of already existing subclinical atherosclerotic lesions. PMID:24533940

  7. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Shafqat, K [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Pal, S K [St Andrew' s Centre for Plastic Surgery and Burns, Broomfield Hospital, Chelmsford, CM1 7ET (United Kingdom)

    2007-10-15

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO{sub 2}) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO{sub 2}) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO{sub 2} sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures

  8. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Science.gov (United States)

    Kyriacou, P. A.; Shafqat, K.; Pal, S. K.

    2007-10-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  9. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    International Nuclear Information System (INIS)

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  10. Low cerebral blood flow in hypotensive perinatal distress

    International Nuclear Information System (INIS)

    Hypoxic brain injury is the most important neurological problem in the neonatal period and accounts for more neurological deficits in children than any other lesion. The neurological deficits are notably mental retardation, epilepsy and cerebral palsy. The pathogenesis has hitherto been poorly understood. Arterial hypoxia has been taken as the obvious mechanism but this does not fully explain the patho-anatomical findings. In the present investigation we have examined the arterial blood pressure and the cerebral blood flow in eight infants a few hours after birth. The 133Xe clearance technique was used for the cerebral blood flow measurements. The study confirmed that perinatal distress may be associated with low arterial blood pressure, and it was shown that cerebral blood flow is very low, 20 ml/100 g/min or less, in hypotensive perinatal distress. It is concluded that cerebral ischaemia plays a crucial role in the development of perinatal hypoxic brain injury. (author)

  11. Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study

    OpenAIRE

    Sayid Shafi Zuhur; Alper Özel; Selvinaz Velet; Mehmet Sait Buğdacı; Esra Çil; Yüksel Altuntas

    2012-01-01

    OBJECTIVE: To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. METHODS: The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational t...

  12. Local Control of Blood Flow

    Science.gov (United States)

    Clifford, Philip S.

    2011-01-01

    Organ blood flow is determined by perfusion pressure and vasomotor tone in the resistance vessels of the organ. Local factors that regulate vasomotor tone include myogenic and metabolic autoregulation, flow-mediated and conducted responses, and vasoactive substances released from red blood cells. The relative importance of each of these factors…

  13. The pulmonary artery does not participate in the blood supply of lung cancer: experimental and DSA study

    International Nuclear Information System (INIS)

    Objective: To investigate whether or not the pulmonary artery participates in the blood supply of lung cancer and its change of morphology and blood flow in lung cancer. Methods: Two different colors of silicone were injected separately into the bronchial and pulmonary arteries of 33 rat models with squamous cell carcinoma of lung. The origin of blood supply of lung cancer and the morphologic change of pulmonary artery were observed under a stereo-microscope. The DSA of bronchial and pulmonary artery were performed simultaneously in 28 patients with lung cancer. Results: The pulmonary branch of rat and patients were reduced,thinned and occluded in the affected lung. The pulmonary artery did not form tumor vessel,and pulmonary blood flow and perfusion were reduced or absent in the affected area. Conclusion: The pulmonary artery did not participate in the blood supply of lung cancer. It is unreasonable to perform transcatheter chemo-embolization for lung cancer via pulmonary artery

  14. Mapping blood flow directionality in the human brain.

    Science.gov (United States)

    Park, Sung-Hong; Do, Won-Joon; Choi, Seung Hong; Zhao, Tiejun; Bae, Kyongtae Ty

    2016-07-01

    Diffusion properties of tissue are often expressed on the basis of directional variance, i.e., diffusion tensor imaging. In comparison, common perfusion-weighted imaging such as arterial spin labeling yields perfusion in a scalar quantity. The purpose of this study was to test the feasibility of mapping cerebral blood flow directionality using alternate ascending/descending directional navigation (ALADDIN), a recently-developed arterial spin labeling technique with sensitivity to blood flow directions. ALADDIN was applied along 3 orthogonal directions to assess directional blood flow in a vector form and also along 6 equally-spaced directions to extract blood flow tensor matrix (P) based on a blood flow ellipsoid model. Tensor elements (eigenvalues, eigenvectors, etc) were calculated to investigate characteristics of the blood flow tensor, in comparison with time-of-flight MR angiogram. While the directions of the main eigenvectors were heterogeneous throughout the brain, regional clusters of blood flow directionality were reproducible across subjects. The technique could show heterogeneous blood flow directionality within and around brain tumor, which was different from that of the contralateral normal side. The proposed method is deemed to provide information of blood flow directionality, which has not been demonstrated before. The results warrant further studies to assess changes in the directionality map as a function of scan parameters, to understand the signal sources, to investigate the possibility of mapping local blood perfusion directionality, and to evaluate its usefulness for clinical diagnosis. PMID:26968145

  15. Simple Radiowave-Based Method For Measuring Peripheral Blood Flow Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Project objective is to design small radio frequency based flow probes for the measurement of blood flow velocity in peripheral arteries such as the femoral artery and middle cerebral artery. The result will be the technological capability to measure peripheral blood flow rates and flow changes during various environmental stressors such as microgravity without contact to the individual being monitored. This technology may also lead to an easier method of detecting venous gas emboli during extravehicular activities.

  16. MUSCLE METABOLISM WITH BLOOD FLOW RESTRICTION IN CHRONIC FATIGUE SYNDROME

    OpenAIRE

    McCully, Kevin K; Smith, Sinclair; Rajaei, Sheeva; Leigh, John S.; Natelson, Benjamin H

    2003-01-01

    The purpose of this study was to determine if chronic fatigue syndrome (CFS) is associated with reduced blood flow and muscle oxidative metabolism. Patients with CFS according to CDC criteria (n=19) were compared to normal sedentary subjects (n = 11). Muscle blood flow was measured in the femoral artery with Doppler ultrasound after exercise. Muscle metabolism was measured in the medial gastrocnemius muscle using 31P magnetic resonance spectroscopy (MRS). Muscle oxygen saturation and blood vo...

  17. Transplacental diffusion and blood flow of gravid bovine uterus

    International Nuclear Information System (INIS)

    Electromagnetic blood flow transducers and uterine arterial, uterine venous, umbilical venous, fetal femoral arterial, and fetal femoral venous catheters were implanted in 11 cows on day 161 +/- 4 of gestation. Antipyrine (0.66 M) plus NaCl (0.16 M) dissolved in deuterium oxide (D2O), or H2O, was infused at a constant rate into the fetal femoral vein catheter. Concentrations of antipyrine and D2O in uterine arterial and venous blood and antipyrine in fetal arterial and umbilical venous blood, as well as middle uterine arterial blood flow (electromagnetic transducer), were determined. Antipyrine and D2O gave similar estimates (steady-state diffusion method) of gravid uterine blood flow. In addition, the slope of the regression of D2O on antipyrine estimates was not different from one. Electromagnetic transducers gave estimates of uterine blood flow that were 32-42% of those obtained with steady-state diffusion but were correlated with estimates obtained by use of both antipyrine and D2O. The transplacental clearance rate of antipyrine was similar (per kg placenta) to that observed in ewes. It was suggested that the maternal and fetal microvasculatures of the bovine placenta could have a concurrent arrangement with vascular shunts or maldistribution of flows, as has been suggested for the ewe

  18. Effects of Bolus and Continuous Nasogastric Feeding on Gastric Emptying, Small Bowel Water Content, Superior Mesenteric Artery Blood Flow, and Plasma Hormone Concentrations in Healthy Adults

    OpenAIRE

    Chowdhury, Abeed H.; Murray, Kathryn; Hoad, Caroline L.; Costigan, Carolyn; Marciani, Luca; Macdonald, Ian A.; Bowling, Timothy E.; Lobo, Dileep N

    2016-01-01

    Objective: We aimed to demonstrate the effect of continuous or bolus nasogastric feeding on gastric emptying, small bowel water content, and splanchnic blood flow measured by magnetic resonance imaging (MRI) in the context of changes in plasma gastrointestinal hormone secretion. Background: Nasogastric/nasoenteral tube feeding is often complicated by diarrhea but the contribution of feeding strategy to the etiology is unclear. Methods: Twelve healthy adult male participants who underwent naso...

  19. In vivo quantification of hyperoxic arterial blood water T1.

    Science.gov (United States)

    Siero, Jeroen C W; Strother, Megan K; Faraco, Carlos C; Hoogduin, Hans; Hendrikse, Jeroen; Donahue, Manus J

    2015-11-01

    Normocapnic hyperoxic and hypercapnic hyperoxic gas challenges are increasingly being used in cerebrovascular reactivity (CVR) and calibrated functional MRI experiments. The longitudinal arterial blood water relaxation time (T1a) change with hyperoxia will influence signal quantification through mechanisms relating to elevated partial pressure of plasma-dissolved O2 (pO2) and increased oxygen bound to hemoglobin in arteries (Ya) and veins (Yv). The dependence of T1a on Ya and Yv has been elegantly characterized ex vivo; however, the combined influence of pO2, Ya and Yv on T1a in vivo under normal ventilation has not been reported. Here, T1a is calculated during hyperoxia in vivo by a heuristic approach that evaluates T1 -dependent arterial spin labeling (ASL) signal changes to varying gas stimuli. Healthy volunteers (n = 14; age, 31.5 ± 7.2 years) were scanned using pseudo-continuous ASL in combination with room air (RA; 21% O2/79% N2), hypercapnic normoxic (HN; 5% CO2/21% O2/74% N2) and hypercapnic hyperoxic (HH; 5% CO2/95% O2) gas administration. HH T1a was calculated by requiring that the HN and HH cerebral blood flow (CBF) change be identical. The HH protocol was then repeated in patients (n = 10; age, 61.4 ± 13.3 years) with intracranial stenosis to assess whether an HH T1a decrease prohibited ASL from being performed in subjects with known delayed blood arrival times. Arterial blood T1a decreased from 1.65 s at baseline to 1.49 ± 0.07 s during HH. In patients, CBF values in the affected flow territory for the HH condition were increased relative to baseline CBF values and were within the physiological range (RA CBF = 36.6 ± 8.2 mL/100 g/min; HH CBF = 45.2 ± 13.9 mL/100 g/min). It can be concluded that hyperoxic (95% O2) 3-T arterial blood T1aHH = 1.49 ± 0.07 s relative to a normoxic T1a of 1.65 s. PMID:26419505

  20. Vasogen's immune modulation therapy (IMT) improves postischemic foot skin blood flow and transcutaneous pO(2) recovery rates in patients with advanced peripheral arterial occlusive disease

    DEFF Research Database (Denmark)

    Edvinsson, L I; Edvinsson, M L; Angus Deveber, G

    2003-01-01

    or Vasogen's IMT over a 9-week period. Dorsal foot skin blood flow was assessed directly using laser Doppler fluxmetry (LDF) and indirectly using measurement of transcutaneous pO(2) (tcpO(2)). Key outcome measures of skin blood flow were, for LDF: resting values, peak postischemic values, and the total time...... to reach peak values following release from 4 min of total foot ischemia and, for tcpO(2): resting values and the time for tcpO(2) to reach 50% of the pre-ischemia value. Measurements were carried out at baseline, at weeks 3, 6, and 9, and at 2 months post-therapy. RESULTS: No significant differences were...... in time to peak blood flow (p=0.026) vs a 7.9 s decrease in the placebo group (p=ns). Similar but less striking results were achieved for tcpO(2) recovery time to 50% of pre-ischemia values (treated group, p=0.035; placebo group, p=ns). CONCLUSION: Vasogen's IMT improved recovery rates of postischemic...

  1. Middle cerebral artery blood velocity and plasma catecholamines during exercise

    DEFF Research Database (Denmark)

    Pott, F; Jensen, K; Hansen, H;

    1996-01-01

    . Vmean increased by 31 +/- 3% and 48 +/- 4%, respectively, and this was significantly higher compared to handgrip (P < 0.05). During maximal cycling, plasma adrenaline increased from 0.21 +/- 0.04 nmol L-1 at rest to 4.18 +/- 1.46 nmol L-1, and noradrenaline increased from 0.79 +/- 0.08 to 12.70 +/- 1......During dynamic exercise, mean blood velocity (Vmean) in the middle cerebral artery (MCA) demonstrates a graded increase to work rate and reflects regional cerebral blood flow. At a high work rate, however, vasoactive levels of plasma catecholamines could mediate vasoconstriction of the MCA and...... thereby elevate Vmean at a given volume flow. To evaluate transcranial Doppler-determined Vmean at high plasma catecholamine levels, seven elite cyclists performed a maximal performance test on a bicycle ergometer. Results were compared with those elicited during five incremental exercise bouts and during...

  2. Evaluation of the Effects of Acupuncture on Blood Flow in Humans with Ultrasound Color Doppler Imaging

    OpenAIRE

    Takayama, Shin; WATANABE, Masashi; Kusuyama, Hiroko; Nagase, Satoru; Seki, Takashi; Nakazawa, Toru; Yaegashi, Nobuo

    2012-01-01

    Color Doppler imaging (CDI) can be used to noninvasively create images of human blood vessels and quantitatively evaluate blood flow in real-time. The purpose of this study was to assess the effects of acupuncture on the blood flow of the peripheral, mesenteric, and retrobulbar arteries by CDI. Statistical significance was defined as P values less than 0.05. Blood flow in the radial and brachial arteries was significantly lower during needle stimulation on LR3 than before in healthy volunteer...

  3. Intrinsic regulation of blood flow in adipose tissue

    DEFF Research Database (Denmark)

    Henriksen, O; Nielsen, Steen Levin; Paaske, W

    1976-01-01

    Previous studies on intact human subcutaneous tissue have shown, that blood flow remains constant during minor changes in perfusion pressure. This so-called autoregulatory response has not been demonstrable in isolated preparations of adipose tissue. In the present study on isolated, denervated...... vasoconstriction with pronounced flow reduction. These two reactions may be important for local regulation of blood flow in subcutaneous tissue during orthostatic changes in arterial and venous pressure. It is concluded that the response in adipose tissue to changes in arterial pressure (autoregulation), venous...... subcutaneous tissue in female rabbits only 2 of 12 expts. revealed an autoregulatory response during reduction in arterial perfusion pressure. Effluent blood flow from the tissue in the control state was 15.5 ml/100 g-min (S.D. 6.4, n = 12) corresponding to slight vasodilatation of the exposed tissue...

  4. DETERMINATION OF AMMONIA IN EAR-LOBE CAPILLARY BLOOD IS AN ALTERNATIVE TO ARTERIAL BLOOD AMMONIA

    NARCIS (Netherlands)

    HUIZENGA, [No Value; GIPS, CH; CONN, HO; JANSEN, PLM

    1995-01-01

    Blood ammonia determination is a laboratory test to diagnose hepatic encephalopathy. Arterial blood is superior to peripheral venous blood ammonia because of ammonia metabolism in muscle. We have compared capillary with arterial whole blood ammonia as capillary sampling is an attractive alternative.

  5. Endovascular blood flow measurement system

    Science.gov (United States)

    Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Krivoshapkin, A. L.; Orlov, K. Yu

    2016-06-01

    In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity-pressure” and “flow rate-energy flow rate” diagrams as important characteristics of the blood flow. The measurement system presented here can be used as an additional instrument in neurosurgery for assessment and monitoring of the operation procedure. Clinical data obtained with the system are used for construction of mathematical models and patient-specific simulations. The monitoring of the blood flow parameters during endovascular interventions was approved by the Ethics Committee at the Meshalkin Novosibirsk Research Institute of Circulation Pathology and included in certain surgical protocols for pre-, intra- and postoperative examinations.

  6. Nocturnal variations in peripheral blood flow, systemic blood pressure, and heart rate in humans

    DEFF Research Database (Denmark)

    Sindrup, J H; Kastrup, J; Christensen, H;

    1991-01-01

    Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage uni...... than 0.0001). The synchronism of the nocturnal subcutaneous hyperemia and the decrease in systemic mean arterial blood pressure point to a common, possibly central nervous or humoral, eliciting mechanism.......Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage unit...

  7. Blood flow in the choriocapillaris

    OpenAIRE

    Zouache, M. A.; Eames, I; Luthert, P J

    2015-01-01

    The choriocapillaris is a capillary bed located in a thin layer adjacent to the outer retina and is part of the oxygen delivery system to the photoreceptors of the eye. The blood flow is approximately planar and is serviced by microvessels, which join the choriocapillaris through inlets perpendicular to its plane. Capillaries are densely organised and separated by avascular septal posts, which direct the blood flow. The capillary bed is composed of a juxtaposition of tessellating vascular uni...

  8. Effects of flow geometry on blood viscoelasticity.

    Science.gov (United States)

    Thurston, George B; Henderson, Nancy M

    2006-01-01

    The viscoelastic properties of blood are dominated by microstructures formed by red cells. The microstructures are of several types such as irregular aggregates, rouleaux, and layers of aligned cells. The dynamic deformability of the red cells, aggregation tendency, cell concentration, size of confining vessel and rate of flow are determining factors in the microstructure. Viscoelastic properties, viscosity and elasticity, relate to energy loss and storage in flowing blood while relaxation time and Weissenberg number play a role in assessing the importance of the elasticity relative to the viscosity. These effects are shown herein for flow in a large straight cylindrical tube, a small tube, and a porous medium. These cases approximate the geometries of the arterial system: large vessels, small vessels and vessels with many branches and bifurcations. In each case the viscosity, elasticity, relaxation time and Weissenberg number for normal human blood as well as blood with enhanced cell aggregation tendency and diminished cell deformability are given. In the smaller spaces of the microtubes and porous media, the diminished viscosity shows the possible influence of the Fåhraeus-Lindqvist effect and at high shear rates, the viscoelasticity of blood shows dilatancy. This is true for normal, aggregation enhanced and hardened cells. PMID:17148856

  9. Measuring bovine mammary gland blood flow using a transit time ultrasonic flow probe.

    Science.gov (United States)

    Gorewit, R C; Aromando, M C; Bristol, D G

    1989-07-01

    Lactating cattle were used to validate a transit time ultrasonic blood flow metering system for measuring mammary gland arterial blood flow. Blood flow probes were surgically placed around the right external pudic artery. An electromagnetic flow probe was implanted in tandem with the ultrasonic probe in two cows for comparative measurements. The absolute accuracy of the implanted flow probes was assessed in vivo by mechanical means on anesthetized cows after 2 to 3 wk of implantation. The zero offset of the ultrasonic probes ranged from -12 to 8 ml/min. When the ultrasonic probe was properly implanted, the slopes of the calibration curves were linear and ranged from .92 to .95, tracking absolute flow to within 8%. The transit time instrument's performance was examined under a variety of physiological conditions. These included milking and hormone injections. The transit time ultrasonic flow meter accurately measured physiological changes in mammary arterial blood flow in chronically prepared conscious cattle. Blood flow increased 29% during milking. Epinephrine decreased mammary blood flow by 90 to 95%. Oxytocin doses increased mammary blood flow by 15 to 24%. PMID:2674232

  10. Noninvasive method of estimating human newborn regional cerebral blood flow

    International Nuclear Information System (INIS)

    A noninvasive method of estimating regional cerebral blood flow (rCBF) in premature and full-term babies has been developed. Based on a modification of the 133Xe inhalation rCBF technique, this method uses eight extracranial NaI scintillation detectors and an i.v. bolus injection of 133Xe (approximately 0.5 mCi/kg). Arterial xenon concentration was estimated with an external chest detector. Cerebral blood flow was measured in 15 healthy, neurologically normal premature infants. Using Obrist's method of two-compartment analysis, normal values were calculated for flow in both compartments, relative weight and fractional flow in the first compartment (gray matter), initial slope of gray matter blood flow, mean cerebral blood flow, and initial slope index of mean cerebral blood flow. The application of this technique to newborns, its relative advantages, and its potential uses are discussed

  11. Factors Influencing the Disturbed Flow Patterns Downstream of Curved Atherosclerotic Arteries

    Institute of Scientific and Technical Information of China (English)

    Biyue Liu

    2008-01-01

    Pulsatile blood flows in curved atherosclerotic arteries are studied by com-puter simulations. Computations are carried out with various values of physiological parameters to examine the effects of flow parameters on the disturbed flow patterns downstream of a curved artery with a stenosis at the inner wall. The numerical re-sults indicate a strong dependence of flow pattern on the blood viscosity and inlet flow rate, while the influence of the inlet flow profile to the flow pattem in downstream is negligible.

  12. Caffeine reduces myocardial blood flow during exercise.

    Science.gov (United States)

    Higgins, John P; Babu, Kavita M

    2013-08-01

    Caffeine consumption has been receiving increased interest from both the medical and lay press, especially given the increased amounts now available in energy products. Acute ingestion of caffeine usually increases cardiac work; however, caffeine impairs the expected proportional increase in myocardial blood flow to match this increased work of the heart, most notably during exercise. This appears to be mainly due to caffeine's effect on blocking adenosine-induced vasodilatation in the coronary arteries in normal healthy subjects. This review summarizes the available medical literature specifically relating to pure caffeine tablet ingestion and reduced exercise coronary blood flow, and suggests possible mechanisms. Further studies are needed to evaluate this effect for other common caffeine-delivery systems, including coffee, energy beverages, and energy gels, which are often used for exercise performance enhancement, especially in teenagers and young athletes. PMID:23764265

  13. Blood transfusion requirement in surgery for femoral artery aneurysms

    DEFF Research Database (Denmark)

    Levi, N; Schroeder, T V

    1997-01-01

    Audit of blood usage in various surgical specialities have shown that over-ordering of blood is widespread, causing unnecessary pressure on the transfusion facilities and giving growing concern over the expense of cross-matching blood. The aim of this study was to assess the blood transfusion req...... requirement in patients undergoing surgery for femoral artery aneurysms....

  14. The postural reduction in middle cerebral artery blood velocity is not explained by PaCO2

    DEFF Research Database (Denmark)

    Immink, R V; Secher, N H; Roos, C M; Pott, F; Madsen, P L; van Lieshout, J J

    2006-01-01

    In the normocapnic range, middle cerebral artery mean velocity (MCA Vmean) changes approximately 3.5% per mmHg carbon-dioxide tension in arterial blood (PaCO2) and a decrease in PaCO2 will reduce the cerebral blood flow by vasoconstriction (the CO2 reactivity of the brain). When standing up MCA...

  15. SPECT of brain blood flow

    International Nuclear Information System (INIS)

    Morphological observation of the brain became possible by CT and various informations on vascularity and damages in brain blood barrier (BBB) became obtainable by the combined use of contrast medium. Then the appearance of MRI had enabled to discriminate the cortex and the medula of the brain and to perform MR angiography. However, it was still difficult to observe the cerebral tissue in detail. Recently, nuclear medical procedures have been developed and applied to diagnosis. SPECT images attributable to the distribution of γ-ray from a tracer, which monitors the blood flow and various metabolisms. Thus, investigations of cerebral functions including blood flow metabolism and neural transmission etc. became possible by the technique. Here, SPECT by Xe-133 clearance and 99mTc HMPAO methods were reviewed. For Xe-133 method, subjects positioned in SPECT instrument underwent bolus inhalation of Xe-133, 1850 Mbq followed by washout respiration of room air. During these treatment, cerebral projection and determination of the concentration of Xe-133 CO2 in the expired air were continuously carried out. And the blood flow level per pixel was estimated from SPECT images and the end-tidal Xe-133 concentration curve. This method was thought to be the most excellent method for the determination of local blood flow in respect of accuracy and reproducibility. The tracer distribution expressed the functional level of the stagnant state of blood flow. SPECT provides useful informations to investigate the physiological functions and pathology in the brain. (M.N.)

  16. Doppler blood flow indicator

    OpenAIRE

    Byrtus, David

    2014-01-01

    This bachelor´s thesis deals with basis of ultra-acoustics. The project presents basic information about Doppler effect. It describes the methods of processing and analyzing of velocity and direction of blood at doppler’s systems with modulated and unmodulated carrier wave. The project presents the system design of non-directional doppler indicator with unmodulated carrier wave for 8 MHz frequency, generating intensity of ultrasound 100 mW/cm2 and diameter D-shaped transmitting transducer 8 m...

  17. Dexmedetomidine decreases the oral mucosal blood flow.

    Science.gov (United States)

    Kawaai, Hiroyoshi; Yoshida, Kenji; Tanaka, Eri; Togami, Kohei; Tada, Hitoshi; Ganzberg, Steven; Yamazaki, Shinya

    2013-12-01

    There is an abundance of blood vessels in the oral cavity, and intraoperative bleeding can disrupt operations. There have been some interesting reports about constriction of vessels in the oral cavity, one of which reported that gingival blood flow in cats is controlled by sympathetic α-adrenergic fibres that are involved with vasoconstriction. Dexmedetomidine is a sedative and analgesic agent that acts through the α-2 adrenoceptor, and is expected to have a vasoconstrictive action in the oral cavity. We have focused on the relation between the effects of α-adrenoceptors by dexmedetomidine and vasoconstriction in oral tissues, and assessed the oral mucosal blood flow during sedation with dexmedetomidine. The subjects comprised 13 healthy male volunteers, sedated with dexmedetomidine in a loading dose of 6 μg/kg/h for 10 min and a continuous infusion of 0.7 μg/kg/h for 32 min. The mean arterial pressure (MAP), heart rate (HR), cardiac output (CO), stroke volume (SV), systemic vascular resistance (SVR), and palatal mucosal blood flow (PMBF) were measured at 0, 5, 10, 12, 22, and 32 min after the start of the infusion. The HR, CO, and PBMF decreased significantly during the infusion even though there were no differences in the SV. The SVR increased significantly but the PMBF decreased significantly. In conclusion, PMBF was reduced by the mediating effect of dexmedetomidine on α-2 adrenoceptors. PMID:23958351

  18. CFD simulation of blood flow inside the corkscrew collaterals of the Buerger’s disease

    Directory of Open Access Journals (Sweden)

    Alireza Sharifi

    2016-03-01

    Results: The local velocity patterns, pressure and kinematic viscosity distributions in different segments of the corkscrew collateral artery was demonstrated and discussed for the first time for this kind of artery. The effects of non-Newtonian consideration for the blood viscosity behavior were investigated in different segments of the artery. Moreover, the variations of the blood flow patterns along the artery were investigated in details for each segment. Conclusion: It was found that the flow patterns were affected by the complex geometry of this artery in such a way that it could lead to the presence of sites that were prone to the accumulation of the flowing particles in blood like nicotine. Furthermore, due to the existence of many successive bends in this artery, the variations of kinematic viscosity along this artery were significant, therefore the non-Newtonian behavior of the blood viscosity must be considered.

  19. New blood flow radiopharmaceutical

    International Nuclear Information System (INIS)

    Our program for research into the causes of mental disorders such as schizophrenia, manic depressive illness and senile dementia has led us to the development of a new radiopharmaceutical agent, IDNNA (4-iodo-2,5-dimethoxy-N,N-dimethylamphetamine). A series of some 15 different 131I labeled molecules with various substitutions on the amine were synthesized and tested, and the uptake of the 131I labeled conpounds in rats was measured. The dimethyl amine (IDNNA) had the best brain uptake and brain/blood ratio. When injected into a dog and scanned with a whole-body scanner, the uptake in the brain could be clearly seen and quantified. Plasma sampling at the same time showed that the maximum brain/blood ratio of 8.7 occurred at 8 min after injection, and the concentration in brain remained high for at least 15 min. Labeling is achieved by reacting 131ICl and the precursor, 2,5-dimethoxy-N,N-dimethyl amphetamine, in glacial acetic acid; the reaction is complete in less than one minute

  20. Calculation of arterial wall temperature in atherosclerotic arteries: effect of pulsatile flow, arterial geometry, and plaque structure

    Directory of Open Access Journals (Sweden)

    Kim Taehong

    2007-03-01

    Full Text Available Abstract Background This paper presents calculations of the temperature distribution in an atherosclerotic plaque experiencing an inflammatory process; it analyzes the presence of hot spots in the plaque region and their relationship to blood flow, arterial geometry, and inflammatory cell distribution. Determination of the plaque temperature has become an important topic because plaques showing a temperature inhomogeneity have a higher likelihood of rupture. As a result, monitoring plaque temperature and knowing the factors affecting it can help in the prevention of sudden rupture. Methods The transient temperature profile in inflamed atherosclerotic plaques is calculated by solving an energy equation and the Navier-Stokes equations in 2D idealized arterial models of a bending artery and an arterial bifurcation. For obtaining the numerical solution, the commercial package COMSOL 3.2 was used. The calculations correspond to a parametric study where arterial type and size, as well as plaque geometry and composition, are varied. These calculations are used to analyze the contribution of different factors affecting arterial wall temperature measurements. The main factors considered are the metabolic heat production of inflammatory cells, atherosclerotic plaque length lp, inflammatory cell layer length lmp, and inflammatory cell layer thickness dmp. Results The calculations indicate that the best location to perform the temperature measurement is at the back region of the plaque (0.5 ≤ l/lp ≤ 0.7. The location of the maximum temperature, or hot spot, at the plaque surface can move during the cardiac cycle depending on the arterial geometry and is a direct result of the blood flow pattern. For the bending artery, the hot spot moves 0.6 millimeters along the longitudinal direction; for the arterial bifurcation, the hot spot is concentrated at a single location due to the flow recirculation observed at both ends of the plaque. Focusing on the

  1. Occlusion cuff for routine measurement of digital blood pressure and blood flow

    DEFF Research Database (Denmark)

    Lassen, N A; Krähenbühl, B; Hirai, M

    1977-01-01

    A miniaturized blood pressure cuff made of plastic material and applicable to fingers and toes is described. The cuff was compared to rubber cuffs and to bladder-free cuffs. It was found to be more reliable than the former type and much easier to use than the latter type. It is recommended for us...... in conjunction with a mercury-in-Silastic strain gauge for routine measurement of digital blood pressure and blood flow in patients with arterial disease....

  2. Cerebral blood-flow tomography

    DEFF Research Database (Denmark)

    Lassen, N A; Henriksen, L; Holm, S;

    1983-01-01

    Tomographic maps of local cerebral blood flow (CBF) were obtained with xenon-133 and with isopropyl-amphetamine-iodine-123 (IMP) in 11 subjects: one normal, two tumor cases, and eight cerebrovascular cases. A highly sensitive four-face, rapidly rotating, single-photon emission tomograph was used...... sampling, and with low radiation exposure to patient and personnel. On the other hand, IMP gives an image of slightly higher resolution. It also introduces a new class of iodinated brain-seeking compounds allowing, perhaps, imaging of other functions more important than mere blood flow....

  3. Heart and Artery Damage and High Blood Pressure

    Science.gov (United States)

    ... Stroke More Heart and Artery Damage and High Blood Pressure Updated:Oct 22,2015 There are several harmful ... was last reviewed on 08/04/2014. High Blood Pressure • Home • About High Blood Pressure (HBP) • Why HBP ...

  4. Uteroplacental blood flow during alkalosis in the sheep

    International Nuclear Information System (INIS)

    Uteroplacental blood flow was measured by the radioactive-microsphere technique in eight near-term pregnant ewes during a normal control period and during maternal metabolic alkalosis. All measurements were made on awake, unanesthetized animals. Alkalosis, defined for this study as an arterial pH of 7.60 or greater, was produced by the oral administration of sodium bicarbonate, 3 g/kg body wt. The rise in pH thus produced was unaccompanied by significant changes in systemic arterial blood pressure and cardiac output, while maternal arterial P/sub CO2/ rose slightly from control levels. Cotyledonary blood flow declined from a control value of 1.177 ml/min to 1.025 ml/min during alkalosis. This decline of 13 percent in cotyledonary blood flow is significant (P less than 0.02). Blood flow to the remaining uterine tissue, or noncotyledonary uterus, did not change with alkalosis, being maintained at approximately 195 ml/min. It is concluded that maternal alkalosis, unaccompanied by major changes in P /sub CO2/ and systemic arterial pressure, causes a small increase in the resistance of the uteroplacental circulation

  5. Non-Newtonian effects of blood on LDL transport inside the arterial lumen and across multi-layered arterial wall with and without stenosis

    Science.gov (United States)

    Deyranlou, Amin; Niazmand, Hamid; Sadeghi, Mahmood-Reza; Mesri, Yaser

    2016-06-01

    Blood non-Newtonian behavior on low-density lipoproteins (LDL) accumulation is analyzed numerically, while fluid-multilayered arteries are adopted for nonstenotic and 30%-60% symmetrical stenosed models. Present model considers non-Newtonian effects inside the lumen and within arterial layers simultaneously, which has not been examined in previous studies. Navier-Stokes equations are solved along with the mass transport convection-diffusion equations and Darcy’s model for species transport inside the luminal flow and across wall layers, respectively. Carreau model for the luminal flow and the modified Darcy equation for the power-law fluid within arterial layers are employed to model blood rheological characteristics, appropriately. Results indicate that in large arteries with relatively high Reynolds number Newtonian model estimates LDL concentration patterns well enough, however, this model seriously incompetent for regions with low WSS. Moreover, Newtonian model for plasma underestimates LDL concentration especially on luminal surface and across arterial wall. Therefore, applying non-Newtonian model seems essential for reaching to a more accurate estimation of LDL distribution in the artery. Finally, blood flow inside constricted arteries demonstrates that LDL concentration patterns along the stenoses inside the luminal flow and across arterial layers are strongly influenced as compared to the nonstenotic arteries. Additionally, among four stenosis severity grades, 40% stenosis is prone to more LDL accumulation along the post-stenotic regions.

  6. Mathematical Analysis of Casson Fluid Model for Blood Rheology in Stenosed Narrow Arteries

    OpenAIRE

    Venkatesan, J.; D. S. Sankar; Hemalatha, K.; Yazariah Yatim

    2013-01-01

    The flow of blood through a narrow artery with bell-shaped stenosis is investigated, treating blood as Casson fluid. Present results are compared with the results of the Herschel-Bulkley fluid model obtained by Misra and Shit (2006) for the same geometry. Resistance to flow and skin friction are normalized in two different ways such as (i) with respect to the same non-Newtonian fluid in a normal artery which gives the effect of a stenosis and (ii) with respect to the Newtonian fluid in the st...

  7. Regional cerebral blood flow in diabetic patients

    International Nuclear Information System (INIS)

    N-isopropyl-p-123I-iodoamphetamine (IMP) was used to quantify the regional cerebral blood flow (r-CBF) in 11 diabetic patients (average age; 67.9 years) and 12 non-diabetic subjects (average age; 67.4 years), none of whom had (cerebrovascular disease (CVD) on CT studies. A reference sampling method by continuous arterial blood sampling was used to quantify r-CBF. There were no significant differences in physiological or laboratory data between diabetic and non-diabetic groups except for fasting plasma glucose and HbA1c levels. The average of r-CBF in each region of cerebrum and cerebellum was significantly lower in diabetic group than that in the control group (p<0.01). These observations show that r-CBF of diabetic patients is reduced, even in the absence of findings of CVD on a CT study. (author)

  8. Regional cerebral blood flow in diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Nagamachi, Shigeki; Ono, Shinnichi; Nishikawa, Takushi (Nichinan Hospital of Miyazaki Prefecture (Japan)) (and others)

    1993-02-01

    N-isopropyl-p-[sup 123]I-iodoamphetamine (IMP) was used to quantify the regional cerebral blood flow (r-CBF) in 11 diabetic patients (average age; 67.9 years) and 12 non-diabetic subjects (average age; 67.4 years), none of whom had (cerebrovascular disease (CVD) on CT studies). A reference sampling method by continuous arterial blood sampling was used to quantify r-CBF. There were no significant differences in physiological or laboratory data between diabetic and non-diabetic groups except for fasting plasma glucose and HbA[sub 1c] levels. The average of r-CBF in each region of cerebrum and cerebellum was significantly lower in diabetic group than that in the control group (p<0.01). These observations show that r-CBF of diabetic patients is reduced, even in the absence of findings of CVD on a CT study. (author).

  9. Pulsatile blood flow, shear force, energy dissipation and Murray's Law

    Directory of Open Access Journals (Sweden)

    Bengtsson Hans-Uno

    2006-08-01

    Full Text Available Abstract Background Murray's Law states that, when a parent blood vessel branches into daughter vessels, the cube of the radius of the parent vessel is equal to the sum of the cubes of the radii of daughter blood vessels. Murray derived this law by defining a cost function that is the sum of the energy cost of the blood in a vessel and the energy cost of pumping blood through the vessel. The cost is minimized when vessel radii are consistent with Murray's Law. This law has also been derived from the hypothesis that the shear force of moving blood on the inner walls of vessels is constant throughout the vascular system. However, this derivation, like Murray's earlier derivation, is based on the assumption of constant blood flow. Methods To determine the implications of the constant shear force hypothesis and to extend Murray's energy cost minimization to the pulsatile arterial system, a model of pulsatile flow in an elastic tube is analyzed. A new and exact solution for flow velocity, blood flow rate and shear force is derived. Results For medium and small arteries with pulsatile flow, Murray's energy minimization leads to Murray's Law. Furthermore, the hypothesis that the maximum shear force during the cycle of pulsatile flow is constant throughout the arterial system implies that Murray's Law is approximately true. The approximation is good for all but the largest vessels (aorta and its major branches of the arterial system. Conclusion A cellular mechanism that senses shear force at the inner wall of a blood vessel and triggers remodeling that increases the circumference of the wall when a shear force threshold is exceeded would result in the observed scaling of vessel radii described by Murray's Law.

  10. MEASUREMENTS OF THE BLOOD CAPILLARY PRESSURE AND ARTERIAL ELASTICITY

    Institute of Scientific and Technical Information of China (English)

    HuangMengcai; GuZhong; HangWenjing; ZhongQuan; TangFuyong

    1990-01-01

    Describe some new fully automatic instruments for the measurements of the blood capillary pressure (Pcap) and arterial elastic properties in human fingers using a photoelectric plethysmographic technique, With these instruments, the value of Pcap was in good agreement with those reported by other investigators, the arterial elastic properties in human fingers have been successfully measured. The measurements of Pcap and arterial elasticity are now required in clinics because they provide useful and important information for evaluating vascular haemodynamics.

  11. Management of high blood pressure in peripheral arterial disease

    OpenAIRE

    Krzesinski, Jean-Marie

    2005-01-01

    Arterial hypertension (HTA) is a promoter of peripheral arterial disease (PAD) in association with other atherosclerotic risk factors factors. Systolic HTA is the most frequently noted form in such disease, secondary to marked increase in large artery siffness. The existence of PAD confers on the hypertensive patient a very high cardiovascular (CV) risk, requiring an intensive global therapeutical approach. Treating HTA is one of such beneficial actions. The optimal blood pressure (BP) to...

  12. Non-invasive pulmonary blood flow analysis and blood pressure mapping derived from 4D flow MRI

    Science.gov (United States)

    Delles, Michael; Rengier, Fabian; Azad, Yoo-Jin; Bodenstedt, Sebastian; von Tengg-Kobligk, Hendrik; Ley, Sebastian; Unterhinninghofen, Roland; Kauczor, Hans-Ulrich; Dillmann, Rüdiger

    2015-03-01

    In diagnostics and therapy control of cardiovascular diseases, detailed knowledge about the patient-specific behavior of blood flow and pressure can be essential. The only method capable of measuring complete time-resolved three-dimensional vector fields of the blood flow velocities is velocity-encoded magnetic resonance imaging (MRI), often denoted as 4D flow MRI. Furthermore, relative pressure maps can be computed from this data source, as presented by different groups in recent years. Hence, analysis of blood flow and pressure using 4D flow MRI can be a valuable technique in management of cardiovascular diseases. In order to perform these tasks, all necessary steps in the corresponding process chain can be carried out in our in-house developed software framework MEDIFRAME. In this article, we apply MEDIFRAME for a study of hemodynamics in the pulmonary arteries of five healthy volunteers. The study included measuring vector fields of blood flow velocities by phase-contrast MRI and subsequently computing relative blood pressure maps. We visualized blood flow by streamline depictions and computed characteristic values for the left and the right pulmonary artery (LPA and RPA). In all volunteers, we observed a lower amount of blood flow in the LPA compared to the RPA. Furthermore, we visualized blood pressure maps using volume rendering and generated graphs of pressure differences between the LPA, the RPA and the main pulmonary artery. In most volunteers, blood pressure was increased near to the bifurcation and in the proximal LPA, leading to higher average pressure values in the LPA compared to the RPA.

  13. Graft Flow Unaffected by Full Occlusion of Left Anterior Descending Artery during Coronary Artery Bypass Grafting in a Porcine Model

    DEFF Research Database (Denmark)

    Torstensson, Gustav Nils Johannes; Torp, Thomas Lee; Rasuli-Oskuii, Nader;

    2013-01-01

    Background: We investigated in a porcine model whether measuring both the flow distal to an anastomosis and the graft transit time flow (TTF) gives a more accurate picture of the true blood flow in the left anterior descending artery (LAD) than graft TTF measurement alone.Methods: We performed off-pump...... anastomosis, despite a fully occluded LAD. This result suggests that graft TTF measurement alone is not sufficient when performing CABG, and measurement of flow distal to the anastomosis is also necessary to determine the true blood flow in the LAD....

  14. Quantitative myocardial blood flow with Rubidium-82 PET

    DEFF Research Database (Denmark)

    Hagemann, Christoffer E; Ghotbi, Adam A; Kjær, Andreas; Hasbak, Philip

    2015-01-01

    Positron emission tomography (PET) allows assessment of myocardial blood flow in absolute terms (ml/min/g). Quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) extend the scope of conventional semi-quantitative myocardial perfusion imaging (MPI): e.g. in 1...... diagnose and risk stratify CAD patients, while assessing the potential of the modality in clinical practice.......) identification of the extent of a multivessel coronary artery disease (CAD) burden, 2) patients with balanced 3-vessel CAD, 3) patients with subclinical CAD, and 4) patients with regional flow variance, despite of a high global MFR. A more accurate assessment of the ischemic burden in patients with intermediate...

  15. Arterial blood gas levels in high altitude Kashmiri population, India

    Directory of Open Access Journals (Sweden)

    Sheikh Imran Sayeed

    2015-11-01

    Conclusions: The present study might provide useful base line normal values of Arterial Blood Gases for the local population and will be beneficial to the clinicians. [Int J Res Med Sci 2015; 3(11.000: 3283-3287

  16. Arterial Blood Carbonic Acid Inversely Determines Lactic and Organic Acids

    OpenAIRE

    Aiken, Christopher Geoffrey Alexander

    2013-01-01

    Objective: To establish that arterial blood carbonic acid varies inversely with lactic acid in accordance with bicarbonate exchanging for lactate across cell membranes through the anion exchange mechanism to maintain the Gibbs-Donnan equilibrium.

  17. Evaluation of the effects of acupuncture on blood flow in humans with ultrasound color Doppler imaging.

    Science.gov (United States)

    Takayama, Shin; Watanabe, Masashi; Kusuyama, Hiroko; Nagase, Satoru; Seki, Takashi; Nakazawa, Toru; Yaegashi, Nobuo

    2012-01-01

    Color Doppler imaging (CDI) can be used to noninvasively create images of human blood vessels and quantitatively evaluate blood flow in real-time. The purpose of this study was to assess the effects of acupuncture on the blood flow of the peripheral, mesenteric, and retrobulbar arteries by CDI. Statistical significance was defined as P values less than 0.05. Blood flow in the radial and brachial arteries was significantly lower during needle stimulation on LR3 than before in healthy volunteers, but was significantly higher after needle stimulation than before. LR3 stimulation also resulted in a significant decrease in the vascular resistance of the short posterior ciliary artery and no significant change of blood flow through the superior mesenteric artery (SMA) during acupuncture. In contrast, ST36 stimulation resulted in a significant increase in blood flow through the SMA and no significant change in the vascular resistance of the retrobulbar arteries. Additionally, acupuncture at previously determined acupoints in patients with open-angle glaucoma led to a significant reduction in the vascular resistance of the central retinal artery and short posterior ciliary artery. Our results suggest that acupuncture can affect blood flow of the peripheral, mesenteric, and retrobulbar arteries, and CDI can be useful to evaluate hemodynamic changes by acupuncture. PMID:22778772

  18. Verapamil buffering effect on the abrupt elevation in blood pressure, linkage with microcirculatory blood flow.

    Science.gov (United States)

    Gmitrov, J

    2008-01-01

    1 We studied the effects of verapamil on sudden elevation in blood pressure, microcirculation and arterial baroreflex sensitivity (BRS). 2 Thirty experiments (10 controls and 20 with verapamil) were performed in rabbits sedated using pentobarbital infusion (5 mg kg(-1) h(-1)). 3 BRS, mean femoral artery blood pressure (MAP), heart rate (HR) and ear lobe skin microcirculatory blood flow, estimated using microphotoelectric plethysmography (MPPG), were simultaneously measured during 30 min of verapamil infusion (20 mug kg(-1) min(-1)). BRS was assessed from HR and MAP responses to intravenous phenylephrine (Ph) and by power spectral analysis using transfer function (TF) from MAP to the HR (BRS(Ph,TF)). 4 Verapamil significantly increased microcirculatory blood flow, and decreased BRS(Ph,TF) and phenylephrine-induced abrupt elevation in MAP (MAP(AE)). 5 A significant inverse correlation was found between verapamil-induced changes in MAP(AE), BRS and in microcirculatory blood flow, measured before phenylephrine blood pressure ramps (DeltaMAP(AE) with DeltaBRS(TF), r = -0.47, P < 0.036; DeltaMAP(AE) with DeltaMPPG, r = -0.49, P < 0.025). 6 These results suggest involvement of the arterial baroreflex and vascular blood pressure-buffering mechanisms, their enhancement by verapamil, and thus a potential benefit of verapamil in cardiovascular conditions where patients present with abrupt high elevations in blood pressure. PMID:18598288

  19. Blood Flow Restricted Exercise and Vascular Function

    Directory of Open Access Journals (Sweden)

    Masahiro Horiuchi

    2012-01-01

    Full Text Available It is established that regular aerobic training improves vascular function, for example, endothelium-dependent vasodilatation and arterial stiffness or compliance and thereby constitutes a preventative measure against cardiovascular disease. In contrast, high-intensity resistance training impairs vascular function, while the influence of moderate-intensity resistance training on vascular function is still controversial. However, aerobic training is insufficient to inhibit loss in muscular strength with advancing age; thus, resistance training is recommended to prevent sarcopenia. Recently, several lines of study have provided compelling data showing that exercise and training with blood flow restriction (BFR leads to muscle hypertrophy and strength increase. As such, BFR training might be a novel means of overcoming the contradiction between aerobic and high-intensity resistance training. Although it is not enough evidence to obtain consensus about impact of BFR training on vascular function, available evidences suggested that BFR training did not change coagulation factors and arterial compliance though with inconsistence results in endothelial function. This paper is a review of the literature on the impact of BFR exercise and training on vascular function, such as endothelial function, arterial compliance, or other potential factors in comparison with those of aerobic and resistance training.

  20. Noninvasive alternatives to arterial blood sampling in positron emission tomography

    International Nuclear Information System (INIS)

    Positron emission tomography is commonly employed for the quantitative assessment of regional biochemistry. The determination of glucose and oxygen utilization rates using [F-18] 2FDG and [0-15] 0/sub 2/ demand accurate measurement of the driving function producing the observed tissue response. Conventional techniques consist of an arterial or venous puncture with either discrete or continuous sampling of blood label concentrations. A time-of-flight (TOF) probe and expired gas detector have been developed as alternatives to these invasive techniques. The acquisition of serial spectra with the TOF pair (4 x 4cm BaF/sub 2/;XP2020Q;380 psec FWHM), sampling a line through the cardiac chambers, reveals the spatial distribution of activity in the heart and surrounding tissue as a function of time. Region-of-interest analysis of the temporally resolved spectra produce the activity time courses required for analysis of tissue response data. Multigated TOF acquisition using a pulsewatch (LED-phototransistor pair which detects finger-tip blood volume changes) as the gating mechanism promises to provide an easy and accurate method for positioning the TOF probe. Dynamic techniques for the measurement of oxygen utilization rates require both the arterial [0-15] 0/sub 2/ and [0-15] H/sub 2/O concentrations. A heated flow-through plastic (NE 102) beta detector was developed to measure the concentration of label in the alveolar gas which was equilibrated with the blood in the pulmonary capillaries. Combining the TOF probe and expired gas data allows the separation of the oxygen and water components of the input function

  1. Age and gender related differences in aortic blood flow

    DEFF Research Database (Denmark)

    Traberg, Marie Sand; Pedersen, Mads Møller; Hemmsen, Martin Christian; Lönn, Lars; Henneberg, Kaj-Åge; Jensen, Jørgen Arendt

    2012-01-01

    The abdominal aorta (AA) is predisposed to development of abdominal aneurysms (AAA), a focal dilatation of the artery with fatal consequences if left untreated. The blood flow patterns in the AA is thought to play an important role in the development of AAA. The purpose of this work is to investi...

  2. The effect of fetal breathing movements on pulmonary blood flow in fetal sheep.

    Science.gov (United States)

    Savich, R D; Guerra, F A; Lee, C C; Kitterman, J A

    1994-04-01

    In the fetus, normal lung growth requires both fetal breathing movements (FBM) and adequate pulmonary blood flow. We postulated that FBM intermittently increase pulmonary blood flow and may stimulate lung growth through that effect. To test the hypothesis that normal intermittent FBM cause associated intermittent increases in pulmonary blood flow, we studied eight chronically instrumented fetal sheep (gestational ages 125-143 d) on 34 occasions (total study time = 65.7 h). Each fetus had a cuff electromagnetic flow transducer around the left pulmonary artery, electrocortical electrodes, and catheters in the trachea, main pulmonary artery, carotid artery, and amniotic cavity. Mean blood flow though the left pulmonary artery averaged 59 +/- 8 mL/min (mean +/- SEM; per kg: 25 +/- 4 mL/kg/min) and was similar in both the presence (61 +/- 9 mL/min) and absence (57 +/- 7 mL/min) of FBM and during both high and low voltage electrocortical activity. In contrast, in utero phasic pulmonary blood flow varied with FBM, increasing during the inspiratory phase and decreasing during the expiratory phase. Both pulmonary and systemic vascular pressures showed changes in the opposite directions. Arterial pH and blood gas tensions were normal and did not change with FBM or electrocortical activity. We conclude that FBM do not increase mean blood flow through the left pulmonary artery; thus, it is unlikely that FBM stimulate lung growth through changes in pulmonary blood flow. PMID:8047386

  3. Prediction of arterial blood gas values from arterialized earlobe blood gas values in patients treated with mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Honarmand Azim

    2008-01-01

    Full Text Available Background/Objective: Arterial blood gas (ABG analysis is useful in evaluation of the clinical condition of critically ill patients; however, arterial puncture or insertion of an arterial catheter may sometimes be difficult and cause many complications. Arterialized ear lobe blood samples have been described as adequate to gauge gas exchange in acute and chronically ill pediatric patients. Purpose: This study evaluates whether pH, partial pressure of oxygen (PO 2 , partial pressure of carbon dioxide (PCO 2 , base excess (BE, and bicarbonate (HCO 3 values of arterialized earlobe blood samples could accurately predict their arterial blood gas analogs for adult patients treated by mechanical ventilation in an intensive care unit (ICU. Setting: A prospective descriptive study Methods: Sixty-seven patients who were admitted to ICU and treated with mechanical ventilation were included in this study. Blood samples were drawn simultaneously from the radial artery and arterialized earlobe of each patient. Results: Regression equations and mean percentage-difference equations were derived to predict arterial pH, PCO 2 , PO 2 , BE, and HCO 3 -values from their earlobe analogs. pH, PCO 2 , BE, and HCO 3 all significantly correlated in ABG and earlobe values. In spite of a highly significant correlation, the limits of agreement between the two methods were wide for PO 2 . Regression equations for prediction of pH, PCO 2 , BE, and HCO3- values were: arterial pH (pHa = 1.81+ 0.76 x earlobe pH (pHe [r = 0.791, P < 0.001]; PaCO 2 = 1.224+ 1.058 x earlobePCO 2 (PeCO 2 [r = 0.956, P < 0.001]; arterial BE (BEa = 1.14+ 0.95 x earlobe BE (BEe [r= 0.894, P < 0.001], and arterial HCO 3 - (HCO 3 -a = 1.41+ earlobe HCO 3 (HCO 3 -e [r = 0.874, P < 0.001]. The predicted ABG values from the mean percentage-difference equations were derived as follows: pHa = pHe x 1.001; PaCO 2 = PeCO 2 x 0.33; BEa = BEe x 0.57; and HCO 3 -a = HCO 3 -e x 1.06. Conclusions: Arterialized

  4. Flow Quantification from 2D Phase Contrast MRI in Renal Arteries Using Clustering

    Science.gov (United States)

    Zöllner, Frank G.; Monnsen, Jan Ankar; Lundervold, Arvid; Rørvik, Jarle

    We present an approach based on clustering to segment renal arteries from 2D PC Cine MR images to measure blood velocity and flow. Such information are important in grading renal artery stenosis and support the decision on surgical interventions like percutan transluminal angioplasty. Results show that the renal arteries could be extracted automatically and the corresponding velocity profiles could be calculated. Furthermore, the clustering could detect possible phase wrap effects automatically as well as differences in the blood flow patterns within the vessel.

  5. CHARACTERIZATION OF RENAL BLOOD FLOW REGULATION BASED ON WAVELET COEFFICIENTS

    DEFF Research Database (Denmark)

    Pavlov, A.N.; Pavlova, O.N.; Mosekilde, Erik;

    2010-01-01

    The purpose of this study is to demonstrate the possibility of revealing new characteristic features of renal blood flow autoregulation in healthy and pathological states through the application of discrete wavelet transforms to experimental time series for normotensive and hypertensive rats. A...... reduction in the variability of the wavelet coefficients in hypertension is observed at both the microscopic level of the blood flow in efferent arterioles of individual nephrons and at the macroscopic level of the blood pressure in the main arteries. The reduction is manifest in both of the main frequency...

  6. Effect of pregnancy on regional cerebral blood flow

    International Nuclear Information System (INIS)

    Regional cerebral blood flow (r-CBF) of 10 pregnant women were quantified by 133Xe SPECT study with inhalation method before and after artificial abortion. During pregnancy, value of r-CBF in each region except occipital lobe was significantly higher than that of the post abortion. Arterial blood gas was analyzed after SPECT procedure. Pco2 concentration increased significantly after artificial abortion. Although its mechanism is unknown, our preliminary work demonstrates that r-CBF increased by pregnancy. (author)

  7. Effects of midazolam on cerebral blood flow in human volunteers

    International Nuclear Information System (INIS)

    The effects of intravenously administered midazolam on cerebral blood flow were evaluated in eight healthy volunteers using the 133Xe inhalation technique. Six minutes after an intravenous dose of 0.15 mg/kg midazolam, the cerebral blood flow decreased significantly (P less than 0.001) from a value of 40.6 +/- 3.3 to a value of 27.0 +/- 5.0 ml . 100 g-1 . min-1. Cerebrovascular resistance (CVR) increased from 2.8 +/- 0.2 to 3.9 to 0.6 mmHg/(ml . 100 g-1 . min-1)(P less than 0.001). Mean arterial blood pressure decreased significantly (P less than 0.05) from 117 +/- 8 to 109 +/- 9 mmHg and arterial carbon dioxide tension increased from 33.9 +/- 2.3 to 38.6 +/- 3.2 mmHg (P less than 0.05). Arterial oxygen tension remained stable throughout the study, 484 +/- 95 mmHg before the administration of midazolam and 453 +/- 76 mmHg after. All the subjects slept after the injection of the drug and had anterograde amnesia of 24.5 +/- 5 min. The decrease in mean arterial blood pressure was probably not important since it remained in the physiologic range for cerebral blood flow autoregulation. The increase in arterial carbon dioxide tension observed after the midazolam injection may have partially counteracted the effect of this new benzodiazepine on cerebral blood flow. Our data suggest that midazolam might be a safe agent to use for the induction of anethesia in neurosurgical patients with intracranial hypertension

  8. Blood flow dynamics in heart failure

    Science.gov (United States)

    Shoemaker, J. K.; Naylor, H. L.; Hogeman, C. S.; Sinoway, L. I.

    1999-01-01

    BACKGROUND: Exercise intolerance in heart failure (HF) may be due to inadequate vasodilation, augmented vasoconstriction, and/or altered muscle metabolic responses that lead to fatigue. METHODS AND RESULTS: Vascular and metabolic responses to rhythmic forearm exercise were tested in 9 HF patients and 9 control subjects (CTL) during 2 protocols designed to examine the effect of HF on the time course of oxygen delivery versus uptake (protocol 1) and on vasoconstriction during exercise with 50 mm Hg pressure about the forearm to evoke a metaboreflex (protocol 2). In protocol 1, venous lactate and H+ were greater at 4 minutes of exercise in HF versus CTL (Pblood flow and oxygen uptake responses. In protocol 2, mean arterial pressure increased similarly in each group during ischemic exercise. In CTL, forearm blood flow and vascular conductance were similar at the end of ischemic and ambient exercise. In HF, forearm blood flow and vascular conductance were reduced during ischemic exercise compared with the ambient trial. CONCLUSIONS: Intrinsic differences in skeletal muscle metabolism, not vasodilatory dynamics, must account for the augmented glycolytic metabolic responses to moderate-intensity exercise in class II and III HF. The inability to increase forearm vascular conductance during ischemic handgrip exercise, despite a normal pressor response, suggests that enhanced vasoconstriction of strenuously exercising skeletal muscle contributes to exertional fatigue in HF.

  9. Erythrocyte aggregation in flowing blood

    International Nuclear Information System (INIS)

    This paper addresses the issue of whether nonionic contrast media (CM) promote thrombosis by the formation of large, irregular red blood cell aggregates with videomicroscopy and a flow chamber, red blood cell aggregates adjacent to an endothelial cell monolayer were imaged at 17 sec-1 in dilute suspensions (hematocrit, --8) at 370C in plasma with 20% CM by non-red blood cell volume. All aggregates were rouleaux (<100 μm) readily dispersed at higher shear rates. Aggregate length in eight experiments was increased 11% by ioxaglate (320 mg of iodine per milliliter), decreased 58% by diatrizoate (370 mg of iodine per milliliter) but reduced similarly (16%) by iohexol (350 mg of iodine per milliliter) and saline. Iohexol did not enhance platelet aggregation on injured monolayers

  10. 20 CFR 718.105 - Arterial blood-gas studies.

    Science.gov (United States)

    2010-04-01

    ... DEATH DUE TO PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.105 Arterial blood... test shall be offered to the miner unless medically contraindicated. If an exercise blood-gas test is... Appendix C is administered during a hospitalization which ends in the miner's death, then any such...

  11. Dynamic alteration of regional cerebral blood flow during carotid compression and proof of reversibility

    OpenAIRE

    Asahi, Kouichi; Hori, M; Hamasaki, N; Sato, S.; Nakanishi, H; Kuwatsuru, R; Sasai, K; Aoki, S.

    2012-01-01

    Background It is difficult to non-invasively visualize changes in regional cerebral blood flow caused by manual compression of the carotid artery. Purpose To visualize dynamic changes in regional cerebral blood flow during and after manual compression of the carotid artery. Material and Methods Two healthy volunteers were recruited. Anatomic features and flow directions in the circle of Willis were evaluated with time-of-flight magnetic resonance angiography (MRA) and two-dimensional phase-co...

  12. Changes in cerebral blood flow and vasoreactivity to CO(2) measured by Arterial Spin Labeling after 6 days at 4,350 m.

    OpenAIRE

    Villien, Marjorie,; Bouzat, Pierre; Rupp, Thomas; Robach, Paul; Lamalle, Laurent; Troprès, Irène; Estève, François; Krainik, Alexandre; Lévy, Patrick; Warnking, Jan; Verges, Samuel

    2013-01-01

    Changes in cerebral perfusion and CO(2) cerebrovascular reactivity during and immediately after a sojourn at high altitude remain unclear but may be critical for acclimatization. The aim of the present study was to assess the effects of 6days at 4,350m on cerebral perfusion and cerebrovascular reactivity (CVR) to CO(2) by arterial spin labeling (ASL) magnetic resonance imaging at sea level and to compare it with transcranial Doppler (TCD) results at altitude. Eleven healthy male subjects, non...

  13. Giant coronary artery aneurysm seen on blood-pool study.

    Science.gov (United States)

    Trujillo, Alexander; Soontrapa, Suthipong; Singh, Preeti; Sehli, Sharmila; Harris, Jennifer; Suarez, Jose A; Arvandi, Aliakbar; Paone, Ralph F; Meyerrose, Gary E

    2013-01-01

    An 81-year-old man was incidentally found to have a large pericardial cyst on a chest computed tomography. Before surgical removal, an echocardiogram demonstrated that the cyst was more likely a large (7.5 cm) right coronary arterial aneurysm. A cardiac blood-pool study demonstrated a blood-filled structure adjacent to the heart, roughly the same size as the combined size of both the right and left ventricles. Coronary angiography confirmed the presence of a large right coronary artery aneurysm. A coronary aneurysm should be considered when a blood-filled structure is seen adjacent to the heart on a multigated acquisition scan. PMID:23242065

  14. Ozone Therapy on Cerebral Blood Flow: A Preliminary Report

    Directory of Open Access Journals (Sweden)

    Bernardino Clavo

    2004-01-01

    Full Text Available Ozone therapy is currently being used in the treatment of ischemic disorders, but the underlying mechanisms that result in successful treatment are not well known. This study assesses the effect of ozone therapy on the blood flow in the middle cerebral and common carotid arteries. Seven subjects were recruited for the therapy that was performed by transfusing ozone-enriched autologous blood on 3 alternate days over 1 week. Blood flow quantification in the common carotid artery (n = 14 was performed using color Doppler. Systolic and diastolic velocities in the middle cerebral artery (n = 14 were estimated using transcranial Doppler. Ultrasound assessments were conducted at the following three time points: 1 basal (before ozone therapy, 2 after session #3 and 3 1 week after session #3. The common carotid blood flow had increased by 75% in relation to the baseline after session #3 (P < 0.001 and by 29% 1 week later (P = 0.039. In the middle cerebral artery, the systolic velocity had increased by 22% after session #3 (P = 0.001 and by 15% 1 week later (P = 0.035, whereas the diastolic velocity had increased by 33% after session #3 (P < 0.001 and by 18% 1 week later (P = 0.023. This preliminary Doppler study supports the clinical experience of achieving improvement by using ozone therapy in peripheral ischemic syndromes. Its potential use as a complementary treatment in cerebral low perfusion syndromes merits further clinical evaluation.

  15. Ocular Blood Flow Autoregulation Mechanisms and Methods

    Directory of Open Access Journals (Sweden)

    Xue Luo

    2015-01-01

    Full Text Available The main function of ocular blood flow is to supply sufficient oxygen and nutrients to the eye. Local blood vessels resistance regulates overall blood distribution to the eye and can vary rapidly over time depending on ocular need. Under normal conditions, the relation between blood flow and perfusion pressure in the eye is autoregulated. Basically, autoregulation is a capacity to maintain a relatively constant level of blood flow in the presence of changes in ocular perfusion pressure and varied metabolic demand. In addition, ocular blood flow dysregulation has been demonstrated as an independent risk factor to many ocular diseases. For instance, ocular perfusion pressure plays key role in the progression of retinopathy such as glaucoma and diabetic retinopathy. In this review, different direct and indirect techniques to measure ocular blood flow and the effect of myogenic and neurogenic mechanisms on ocular blood flow are discussed. Moreover, ocular blood flow regulation in ocular disease will be described.

  16. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin 131I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions

  17. Hypertension, blood pressure, cognition and cerebral blood flow in the cohort of "Men born 1914"

    OpenAIRE

    Reinprecht, Faina

    2006-01-01

    "Men born 1914" is a population based cohort study of the epidemiology of cardiovascular disease. Five hundred men, born 1914, were examined at the age of 68 and 185 of them were re-examined at 81 years of age. Examination included a medical and a psychological investigation, ultrasonographic measurement of carotid arteries, 24-hour ambulatory blood pressure monitoring, regional cerebral blood flow, and cardiovascular risk factors. It is well known that hypertension plays a major et...

  18. MR evaluation of common femoral arterial flow

    International Nuclear Information System (INIS)

    Flow velocity measurements of the common femoral arteries in 60 lower extremities of 30 healthy subjects and 12 lower extremities of 7 patients with arteriosclerosis obliterans (ASO) were performed by means of magnetic resonance imaging with a use of presaturation bolus tracking (PBT) method. Our PBT method can provide both precise determination of flow velocity and evaluation of flow patterns within 30 minutes in the clinical setting. In phantom study, MR flow velocity had good correlation with actual flow velocity (r=0.997) 30 healthy volunteers were classified into three groups; group I (20-40 years), group II (41-60 years) and group III (61-80 years). Starting time of acceleration (STA) were shortened as the age progressed. Peak reverse velocity (PRV), maximum deceleration rate (MDR), peak forward velocity/mean velocity ratio (PFV/MV) and pulsatility index (PI) were significantly decreased in group III as compared to group I and group II. Although intraluminal flow profile showed almost uniform during acceleration time on MR images, flow profile became disproportioned and reverse flow was observed in the medial portion during deceleration time. These characteristic hemodynamics were recognized in all healthy subjects regardless of the different age group. In ASO, STA was prolonged and PFV, PRV, maximum acceleration rate, MDR, PFV/MV, PI, vascular sectional area, flow volume were significantly decreased (p<0.001) as compared to the control healthy group III. As a result, we obtained marked characteristics such as flattening of curves and disappearance of reverse flow in MR flow waveform. On MR images, disproportion of intraluminal flow profile, decreased flow velocities during acceleration time and disappearance of reverse flow (11 of 12 extremities) during deceleration time were observed. (author)

  19. CFD simulation of blood flow inside the corkscrew collaterals of the Buerger’s disease

    Science.gov (United States)

    Sharifi, Alireza; Charjouei Moghadam, Mohammad

    2016-01-01

    Introduction: Buerger’s disease is an occlusive arterial disease that occurs mainly in medium and small vessels. This disease is associated with Tobacco usage. The existence of corkscrew collateral is one of the established characteristics of the Buerger’s disease. Methods: In this study, the computational fluid dynamics (CFD) simulation of blood flow within the corkscrew artery of the Buerger’s disease is conducted. The geometry of the artery is constructed based on the actual corkscrew artery of a patient diagnosed with the Buerger’s disease. The blood properties are the same as the actual blood properties of the patient. The blood flow rate is taken from the available experimental data in the literature. Results: The local velocity patterns, pressure and kinematic viscosity distributions in different segments of the corkscrew collateral artery was demonstrated and discussed for the first time for this kind of artery. The effects of non-Newtonian consideration for the blood viscosity behavior were investigated in different segments of the artery. Moreover, the variations of the blood flow patterns along the artery were investigated in details for each segment. Conclusion: It was found that the flow patterns were affected by the complex geometry of this artery in such a way that it could lead to the presence of sites that were prone to the accumulation of the flowing particles in blood like nicotine. Furthermore, due to the existence of many successive bends in this artery, the variations of kinematic viscosity along this artery were significant, therefore the non-Newtonian behavior of the blood viscosity must be considered. PMID:27340623

  20. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P < .0001 to P < .05). The nighttime blood pressures...... were almost similar in the two groups (108 vs. 110; 65 vs. 67; 78 vs. 82 mm Hg, NS). Conversely, HR was significantly higher in the patients both in the daytime (86 vs. 72/min, P < .0001) and at night (80 vs. 64/min, P < .0001). Consequently, the reduction in blood pressure and HR from daytime to...

  1. Blood Pump Development Using Rocket Engine Flow Simulation Technology

    Science.gov (United States)

    Kwak, Dochan; Kiris, Cetin

    2001-01-01

    This paper reports the progress made towards developing complete blood flow simulation capability in humans, especially in the presence of artificial devices such as valves and ventricular assist devices. Devices modeling poses unique challenges different from computing the blood flow in natural hearts and arteries. There are many elements needed to quantify the flow in these devices such as flow solvers, geometry modeling including flexible walls, moving boundary procedures and physiological characterization of blood. As a first step, computational technology developed for aerospace applications was extended to the analysis and development of a ventricular assist device (VAD), i.e., a blood pump. The blood flow in a VAD is practically incompressible and Newtonian, and thus an incompressible Navier-Stokes solution procedure can be applied. A primitive variable formulation is used in conjunction with the overset grid approach to handle complex moving geometry. The primary purpose of developing the incompressible flow analysis capability was to quantify the flow in advanced turbopump for space propulsion system. The same procedure has been extended to the development of NASA-DeBakey VAD that is based on an axial blood pump. Due to massive computing requirements, high-end computing is necessary for simulating three-dimensional flow in these pumps. Computational, experimental, and clinical results are presented.

  2. The effect of ventricular assist devices on cerebral blood flow and blood pressure fractality

    International Nuclear Information System (INIS)

    Biological signals often exhibit self-similar or fractal scaling characteristics which may reflect intrinsic adaptability to their underlying physiological system. This study analysed fractal dynamics of cerebral blood flow in patients supported with ventricular assist devices (VAD) to ascertain if sustained modifications of blood pressure waveform affect cerebral blood flow fractality. Simultaneous recordings of arterial blood pressure and cerebral blood flow velocity using transcranial Doppler were obtained from five cardiogenic shock patients supported by VAD, five matched control patients and five healthy subjects. Computation of a fractal scaling exponent (α) at the low-frequency time scale by detrended fluctuation analysis showed that cerebral blood flow velocity exhibited 1/f fractal scaling in both patient groups (α = 0.95 ± 0.09 and 0.97 ± 0.12, respectively) as well as in the healthy subjects (α = 0.86 ± 0.07). In contrast, fluctuation in blood pressure was similar to non-fractal white noise in both patient groups (α = 0.53 ± 0.11 and 0.52 ± 0.09, respectively) but exhibited 1/f scaling in the healthy subjects (α = 0.87 ± 0.04, P < 0.05 compared with the patient groups). The preservation of fractality in cerebral blood flow of VAD patients suggests that normal cardiac pulsation and central perfusion pressure changes are not the integral sources of cerebral blood flow fractality and that intrinsic vascular properties such as cerebral autoregulation may be involved. However, there is a clear difference in the fractal scaling properties of arterial blood pressure between the cardiogenic shock patients and the healthy subjects

  3. Inverse correlation between cerebral blood flow measured by continuous arterial spin-labeling (CASL) MRI and neurocognitive function in children with sickle cell anemia (SCA)

    OpenAIRE

    Strouse, John J.; Cox, Christiane S.; Melhem, Elias R.; Lu, Hanzhang; Kraut, Michael A.; Razumovsky, Alexander; Yohay, Kaleb; van Zijl, Peter C.; Casella, James F.

    2006-01-01

    Overt stroke, clinically “silent” cerebral infarct, and neurocognitive impairment are frequent complications of sickle cell anemia (SCA). Current imaging techniques have limited sensitivity and specificity to identify children at risk for neurocognitive impairment. We prospectively evaluated 24 children with SCA with a neurologic exam, complete blood count, transcranial Doppler ultrasound (TCD), measurement of intelligence quotient (IQ), and magnetic resonance imaging (MRI) with measurement o...

  4. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V; Ladefoged, Søren D; Lönn, Lars

    2012-01-01

    Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...

  5. Regional cerebral blood flow autoregulation in patients with fulminant hepatic failure

    DEFF Research Database (Denmark)

    Larsen, Fin Stolze; Strauss, Gitte Irene; Møller, Kirsten;

    2000-01-01

    The absence of cerebral blood flow autoregulation in patients with fulminant hepatic failure (FHF) implies that changes in arterial pressure directly influence cerebral perfusion. It is assumed that dilatation of cerebral arterioles is responsible for the impaired autoregulation. Recently, fronta...

  6. Doppler colour flow mapping of fetal intracerebral arteries in the presence of central nervous system anomalies

    NARCIS (Netherlands)

    J.W. Wladimiroff (Juriy); R. Heydanus (Rogier); P.A. Stewart (Patricia)

    1993-01-01

    textabstractThe adjunctive role of Doppler colour flow mapping in the evaluation of intracerebral morphology and arterial blood flow in the presence of normal and abnormal central nervous system morphology was determined. A total of 59 fetuses with suspected central nervous system pathology between

  7. Skeletal muscle blood flow responses to hypoperfusion at rest and during rhythmic exercise in humans

    OpenAIRE

    Casey, Darren P.; Joyner, Michael J.

    2009-01-01

    We evaluated the contribution of changes in systemic arterial pressure and local vasodilation to blood flow restoration in contracting human muscles during acute hypoperfusion. Healthy subjects (n = 10) performed rhythmic forearm exercise (10% and 20% of maximum) while a balloon in the brachial artery located above the elbow was inflated. Each trial included 3 min of rest, exercise, exercise with balloon inflation, and exercise after balloon deflation. Forearm blood flow (FBF) was measured us...

  8. Non invasive blood flow measurement in cerebellum detects minimal hepatic encephalopathy earlier than psychometric tests

    OpenAIRE

    Felipo, Vicente; Urios, Amparo; Giménez-Garzó, Carla; Cauli, Omar; Andrés-Costa, Maria-Jesús; González, Olga; Serra, Miguel A; Sánchez-González, Javier; Aliaga, Roberto; Giner-Durán, Remedios; Belloch, Vicente; Montoliu Félix, Carmina

    2014-01-01

    AIM: To assess whether non invasive blood flow measurement by arterial spin labeling in several brain regions detects minimal hepatic encephalopathy.METHODS: Blood flow (BF) was analyzed by arterial spin labeling (ASL) in different brain areas of 14 controls, 24 cirrhotic patients without and 16 cirrhotic patients with minimal hepatic encephalopathy (MHE). Images were collected using a 3 Tesla MR scanner (Achieva 3T-TX, Philips, Netherlands). Pulsed ASL was performed. Patients showing MHE wer...

  9. Altered cerebral blood flow one month after systemic chemotherapy for breast cancer: a prospective study using pulsed arterial spin labeling MRI perfusion.

    Directory of Open Access Journals (Sweden)

    Kelly N H Nudelman

    Full Text Available Cerebral structural and functional alterations have been reported after chemotherapy for non-CNS cancers, yet the causative mechanism behind these changes remains unclear. This study employed a novel, non-invasive, MRI-based neuroimaging measure to provide the first direct longitudinal measurement of resting cerebral perfusion in breast cancer patients, which was tested for association with changes in cognitive function and gray matter density. Perfusion was measured using pulsed arterial spin labeling MRI in women with breast cancer treated with (N = 27 or without (N = 26 chemotherapy and matched healthy controls (N = 26 after surgery before other treatments (baseline, and one month after chemotherapy completion or yoked intervals. Voxel-based analysis was employed to assess perfusion in gray matter; changes were examined in relation to overall neuropsychological test performance and frontal gray matter density changes measured by structural MRI. Baseline perfusion was not significantly different across groups. Unlike control groups, chemotherapy-treated patients demonstrated significantly increased perfusion post-treatment relative to baseline, which was statistically significant relative to controls in the right precentral gyrus. This perfusion increase was negatively correlated with baseline overall neuropsychological performance, but was not associated with frontal gray matter density reduction. However, decreased frontal gray matter density was associated with decreased perfusion in bilateral frontal and parietal lobes in the chemotherapy-treated group. These findings indicate that chemotherapy is associated with alterations in cerebral perfusion which are both related to and independent of gray matter changes. This pattern of results suggests the involvement of multiple mechanisms of chemotherapy-induced cognitive dysfunction. Additionally, lower baseline cognitive function may be a risk factor for treatment

  10. Evaluation of combined, conservative treatment impact on the clinical course, blood flow parameters and muscle perfusion in the group of patients with newly diagnosed, untreated peripheral arterial disease (PAD)

    International Nuclear Information System (INIS)

    Background: Epidemiological studies determined incidence of obliterative atherosclerosis as ranging between 2.45 -10 %. The course of disease is often asymptomatic and demonstration of symptoms occurs when vascular lesions are significantly advanced. This article discusses conservative treatment of patients with PAD whose key complaint was intermittent claudication. The Authors proposed multi-stage treatment regimen of this disease including lifestyle modification, treatment of comorbid disorders, and pharmacotherapy (aspirin, pentoxifylline, buflomedil, L-arginine). The study evaluated influence of 6-month treatment on clinical course, blood flow parameters as well as muscle perfusion. Material/Methods: The participants included 35 patients (14 women - 40.0 %, and 21 men - 60.0 %) aged from 49 to 80 (mean age 68.37 ± 10.25 years) first time in life diagnosed with PAD. Physical examination, standard vascular tests (ankle-brachial, thigh-ankle and thigh-shin indices, maximum flow velocity, PI and RI in selected arteries), perfusion scintigraphy of lower limbs muscles at rest and on exertion were carried out before and after 6 months of treatment. Results: Statistically significant increase of total walking distance (198.0 meters vs. 330.0 meters, p< 0.01) and improvement in average values of perfusion indices of all studied areas were detected at rest and after exercise. For shin perfusion index at rest (right and left) and for thigh perfusion index after exercise (right) the difference was statistically significant at p< 0.05. Conclusions: Combined medical treatment brought on positive effect on patients suffering from recently diagnosed, thus not yet treated atherosclerotic lower limb ischaemia of IIA and IIB stages according to Fontaines scale. (authors)

  11. Pressure passive cerebral blood flow and breakdown of the blood-brain barrier in experimental fetal asphyxia

    DEFF Research Database (Denmark)

    Lou, H C; Lassen, N A; Tweed, W A;

    1979-01-01

    mean arterial blood pressure in the fetuses by blood withdrawal or infusion in this state, CBF was measured at different perfusion pressures (mean arterial blood pressure (MABP) minus central venous pressure (CVP)). A passive flow/pressure relationship--loss of autoregulation--was found, with hyperemia...... reaching CBF values up to 6 times normal at normal MABP of about 60 to 70 mmHg, and severe ischemia reaching CBF values close to zero in large cortical areas at MABP of 30 mmHg. CVP remained essentially unchanged at 10--15 mmHg. The severe and prolonged asphyxia rendered the blood-brain barrier leaky to...

  12. Femoral Blood Flow and Cardiac Output During Blood Flow Restricted Leg Press Exercise

    Science.gov (United States)

    Everett, M. E.; Hackney, K.; Ploutz-Snyder, L.

    2011-01-01

    Low load blood flow restricted resistance exercise (LBFR) causes muscle hypertrophy that may be stimulated by the local ischemic environment created by the cuff pressure. However, local blood flow (BF) during such exercise is not well understood. PURPOSE: To characterize femoral artery BF and cardiac output (CO) during leg press exercise (LP) performed at a high load (HL) and low load (LL) with different levels of cuff pressure. METHODS: Eleven subjects (men/women 4/7, age 31.4+/-12.8 y, weight 68.9+/-13.2 kg, mean+/-SD) performed 3 sets of supine left LP to fatigue with 90 s of rest in 4 conditions: HL (%1-RM/cuff pressure: 80%/0); LL (20%/0); LBFR(sub DBP) (20%/1.3 x diastolic blood pressure, BP); LBFR(sub SBP) (20%/1.3 x supine systolic BP). The cuff remained inflated throughout the LBFR exercise sessions. Artery diameter, velocity time integral (VTI), and stroke volume (SV) were measured using Doppler ultrasound at rest and immediately after each set of exercise. Heart rate (HR) was monitored using a 3-lead ECG. BF was calculated as VTI x vessel cross-sectional area. CO was calculated as HR x SV. The data obtained after each set of exercise were averaged and used for analyses. Multi-level modeling was used to determine the effect of exercise condition on dependent variables. Statistical significance was set a priori at p LL (9.92+/-0.82 cm3) > LBFR(sub dBP)(6.47+/-0.79 cm3) > LBFR(sub SBP) (3.51+/-0.59 cm3). Blunted exercise induced increases occurred in HR, SV, and CO after LBFR compared to HL and LL. HR increased 45% after HL and LL and 28% after LBFR (p<0.05), but SV increased (p<0.05) only after HL. Consequently, the increase (p<0.05) in CO was greater in HL and LL (approximately 3 L/min) than in LBFR (approximately 1 L/min). CONCLUSION: BF during LBFR(sub SBP) was 1/3 of that observed in LL, which supports the hypothesis that local ischemia stimulates the LBFR hypertrophic response. As the cuff did not compress the artery, the ischemia may have occurred

  13. Pulmonary blood flow distribution measured by radionuclide computed tomography

    International Nuclear Information System (INIS)

    Distributions of pulmonary blood flow per unit lung volume were measured in sitting patients with a radionuclide computed tomography (RCT) by intravenously administered Tc-99m macroaggregates of human serum albumin (MAA). Four different types of distribution were distinguished, among which a group referred as type 2 had a three zonal blood flow distribution as previously reported (West and co-workers, 1964). The pulmonary arterial pressure (Pa) and the venous pressure (Pv) were determined in this group of distribution. These values showed satifactory agreements with the pulmonary artery pressure (Par) and the capillary wedged pressure (Pcw) measured by Swan-Ganz catheter in eighteen supine patients. Those good correlations enable to establish a noninvasive methodology for measurement of pulmonary vascular pressures

  14. Cutaneous blood flow in psoriasis

    International Nuclear Information System (INIS)

    The disappearance rate of 133Xe was studied in 20 patients with psoriasis vulgaris, using an epicutaneous labeling technique in involved skin lesions or normal-appearing skin of the proximal extensor site of the forearm. Control experiments were performed in 10 normal subjects. Calculations of the cutaneous blood flow (CBF) in psoriatic skin lesions were performed using a tissue-to-blood partition coefficient for 133Xe, lambda c,pso, of 1.2 ml/100 g/min. lambda c,pso was estimated after the relative content of water, lipids, and proteins had been analyzed in psoriatic skin biopsies of 6 patients with untreated psoriasis. The mean relative content of water was markedly reduced to 23.5 +/- 1.5% (SEM), and lipids and proteins were markedly increased to 2.5 +/- 0.7% and 74.0 +/- 2.2, respectively, compared to previously published data for normal skin (water 72.5%, lipids 1%, proteins 26.5%). Mean CBF in untreated psoriatic skin was 63.5 +/- 9.0 ml/100 g/min. This was significantly higher than the mean CBF in 10 normal subjects, 6.3 +/- 0.5 ml/100 g/min (p much less than 0.0001). Mean CBF in normal-appearing skin in patients with psoriasis was 11.0 +/- 1.3 ml/100 g/min. This was significantly higher than CBF in normal subjects (p less than 0.0002)

  15. Interpretation of Doppler blood flow velocity waveforms using neural networks.

    OpenAIRE

    Baykal, N; Reggia, J. A.; Yalabik, N.; Erkmen, A.; Beksac, M. S.

    1994-01-01

    Doppler umbilical artery blood flow velocity waveform measurement is used in perinatal surveillance for the evaluation of pregnancy status. There is an ongoing debate on the predictive value of Doppler measurements concerning the critical effect of the selection of parameters for the evaluation of Doppler output. In this paper, we describe how neural network methods can be used both to discover relevant classification features and subsequently to classify patients. Classification accuracy var...

  16. Flow Structures in a Healthy and Plaqued Artificial Artery using Fully Index Matched Vascular Flow Facility

    Science.gov (United States)

    Mehdi, Faraz; Jain, Akash; Sheng, Jian

    2014-11-01

    Particle Image Velocimetry measurements are made in a closed loop fully index matched flow facility to study the flow structures and flow wall interactions in healthy and diseased model arteries. The test section is 0.63 m long and the facility is capable of emulating both steady and pulsatile flows under physiologically relevant conditions. The model arteries are in-house developed compliant polymer (PDMS) tubes with 1 cm diameter and 1 mm wall thickness. The Reynolds numbers of flows vary up to 20,000. The plaque is simulated by introducing a radially asymmetric bump that can be varied in shape, size and compliancy. The overall compliancy of the model can be also controlled by varying ratio between the elastomer and the curing agent. The tubes are doped with particles allowing the simultaneous measurements of wall deformation and flows over it. The working fluid in the facility is NaI and is refractive index matched to the PDMS model. This allows flow measurement very close to the wall and measurement of wall shear stress. The aim of this study is to characterize the changes in flow as the compliancy and geometry of blood vessels change due to age or disease. These differences can be used to develop a diagnostic tool to detect early onset of vascular diseases.

  17. Influence of posture on hepatic blood flow

    International Nuclear Information System (INIS)

    Hepatic blood flow was measured in 28 patients in supine and prone positions using the 133Xe-inhalation washout method. Even though the reactions in individual patients were considerably different, a man blood flow of 60.9 ml/100 g/min was unaltered in both positions. This constancy of hepatic blood flow values is valid for patients without liver disease with chronic hepatitis, and with liver cirrhosis. (orig.)

  18. 双胎反向动脉灌注序列征中两胎脐动脉血流阻力指数差值对评估泵血儿预后的临床意义%Clinical value of diffe rence in umbilical artery blood flow resistive index between pump and acardiac twins in pre-dicting outcome of pump twin by twin reversed-arterial perfusion sequence

    Institute of Scientific and Technical Information of China (English)

    陈昌宇; 解丽梅

    2016-01-01

    Objective To investigate the clinical value of umbilical artery blood flow resistance index (RI) difference between pump twins and acardiacus fetus by twin reversed-arterial perfusion (TRAP) sequence. Methods A total of 15 pregnant women with TRAP in China Medical University Affiliated Shengjing Hospital from 2009 to 2014 were enrolled, aged 19-36 years old with mean age of 26.53 years old. The gestational age was 13 - 27 weeks with mean of 21.73 weeks. Umbilical artery blood flow RI of pump twin and acardiacus were respectively measured by ultrasound, and the difference value of umbilical artery blood flow RI was calculated. Results Three pump twins were detected as heart failure, the difference value of their umbilical artery blood flow RI were small as 0.05, 0.07 and 0.13, respectively, and intrauterine death occurred after one week. Eight cases were given radio frequency ablation therapy, the difference value of umbilical artery blood flow RI of 7 pump twins were 0.16 - 0.30, and fetus were survived. The one pump twin showed difference value of umbilical artery blood flow RI of 0.17, and intrauterine death occurred after surgery. The difference value of umbilical artery blood flow RI of one pump twin was 0.34, and given conservative treatment due to the poor blood flow in acardiacus. The difference value of umbilical artery blood flow RI of one pump twin was 0.10, which terminated the pregnancy for maternal pregnancy-induced hypertension. The difference value of umbilical artery blood flow RI of one pump twin was 0.20, which showed chromosomal abnormalities, and one case performed abortion for low gestational age. Conclusion It is demonstrated that the difference value of umbilical artery blood flow RI between pump twin and acardiacus is significant on evaluation and treatment of TRAP, which means the bigger the RI difference value, the better prognosis.%目的:探讨双胎反向动脉灌注序列征(TRAP)中泵血儿与无心畸胎脐动脉血流阻力

  19. Feasibility of Quantifying Arterial Cerebral Blood Volume Using Multiphase Alternate Ascending/Descending Directional Navigation (ALADDIN).

    Science.gov (United States)

    Kim, Ki Hwan; Choi, Seung Hong; Park, Sung-Hong

    2016-01-01

    Arterial cerebral blood volume (aCBV) is associated with many physiologic and pathologic conditions. Recently, multiphase balanced steady state free precession (bSSFP) readout was introduced to measure labeled blood signals in the arterial compartment, based on the fact that signal difference between labeled and unlabeled blood decreases with the number of RF pulses that is affected by blood velocity. In this study, we evaluated the feasibility of a new 2D inter-slice bSSFP-based arterial spin labeling (ASL) technique termed, alternate ascending/descending directional navigation (ALADDIN), to quantify aCBV using multiphase acquisition in six healthy subjects. A new kinetic model considering bSSFP RF perturbations was proposed to describe the multiphase data and thus to quantify aCBV. Since the inter-slice time delay (TD) and gap affected the distribution of labeled blood spins in the arterial and tissue compartments, we performed the experiments with two TDs (0 and 500 ms) and two gaps (300% and 450% of slice thickness) to evaluate their roles in quantifying aCBV. Comparison studies using our technique and an existing method termed arterial volume using arterial spin tagging (AVAST) were also separately performed in five subjects. At 300% gap or 500-ms TD, significant tissue perfusion signals were demonstrated, while tissue perfusion signals were minimized and arterial signals were maximized at 450% gap and 0-ms TD. ALADDIN has an advantage of visualizing bi-directional flow effects (ascending/descending) in a single experiment. Labeling efficiency (α) of inter-slice blood flow effects could be measured in the superior sagittal sinus (SSS) (20.8±3.7%.) and was used for aCBV quantification. As a result of fitting to the proposed model, aCBV values in gray matter (1.4-2.3 mL/100 mL) were in good agreement with those from literature. Our technique showed high correlation with AVAST, especially when arterial signals were accentuated (i.e., when TD = 0 ms) (r = 0

  20. Feasibility of Quantifying Arterial Cerebral Blood Volume Using Multiphase Alternate Ascending/Descending Directional Navigation (ALADDIN)

    Science.gov (United States)

    Kim, Ki Hwan; Choi, Seung Hong; Park, Sung-Hong

    2016-01-01

    Arterial cerebral blood volume (aCBV) is associated with many physiologic and pathologic conditions. Recently, multiphase balanced steady state free precession (bSSFP) readout was introduced to measure labeled blood signals in the arterial compartment, based on the fact that signal difference between labeled and unlabeled blood decreases with the number of RF pulses that is affected by blood velocity. In this study, we evaluated the feasibility of a new 2D inter-slice bSSFP-based arterial spin labeling (ASL) technique termed, alternate ascending/descending directional navigation (ALADDIN), to quantify aCBV using multiphase acquisition in six healthy subjects. A new kinetic model considering bSSFP RF perturbations was proposed to describe the multiphase data and thus to quantify aCBV. Since the inter-slice time delay (TD) and gap affected the distribution of labeled blood spins in the arterial and tissue compartments, we performed the experiments with two TDs (0 and 500 ms) and two gaps (300% and 450% of slice thickness) to evaluate their roles in quantifying aCBV. Comparison studies using our technique and an existing method termed arterial volume using arterial spin tagging (AVAST) were also separately performed in five subjects. At 300% gap or 500-ms TD, significant tissue perfusion signals were demonstrated, while tissue perfusion signals were minimized and arterial signals were maximized at 450% gap and 0-ms TD. ALADDIN has an advantage of visualizing bi-directional flow effects (ascending/descending) in a single experiment. Labeling efficiency (α) of inter-slice blood flow effects could be measured in the superior sagittal sinus (SSS) (20.8±3.7%.) and was used for aCBV quantification. As a result of fitting to the proposed model, aCBV values in gray matter (1.4–2.3 mL/100 mL) were in good agreement with those from literature. Our technique showed high correlation with AVAST, especially when arterial signals were accentuated (i.e., when TD = 0 ms) (r = 0

  1. Regional cerebral blood flow in schizophrenia

    International Nuclear Information System (INIS)

    Regional cerebral blood flow (rCBF) was measured via xenon133 inhalation technique in 23 patients with schizophrenia and 18 age- and sex-matched controls. The mean blood flow to both hemispheres was found to be lower for the patients. The patients and their controls did not differ on interhemispheric differences in blood flow. There were no differences in rCBF between medicated and unmedicated, subchronic and chronic, and paranoid and nonparanoid patients. Hallucinations were associated with reduced blood flow to several postcentral regions

  2. Cerebral blood flow in migraine and cortical spreading depression

    International Nuclear Information System (INIS)

    In a series of migraine patients, carotid arteriography was carried out as part of the clinical evaluation. Nine patients developed a migrainous attack with focal neurological symptoms and headache after the angiography and during the subsequent, ongoing regional cerebral blood flow rCBF study. rCBF was measured by bolus injection of Xenon133 into the internal carotid artery and a gamma camera with 254 collimated scintillation detectors covering the lateral aspect of the hemisphere. This technique depicts rCBF mainly at the level of the superficial cortex, with no depth resolution. The resolution is 1 cm2 providing detailed spatial information of the cortical blood flow. Other methods for measuring local blood flow in animal and man employ a radioactive, freely diffusible tracer, in combination with an autoradiographic technique for the assessment of the tissue concentration, the so-called autoradiographic methods. In the series of patients with spontaneous migraine, rCBF was estimated using an in-vivo application of the autoradiographic principle. Xenon133 was administered by inhalation and the time course of the arterial concentration curve was assessed by a scintillation detector over the upper right lung, since the arterial curve has been found to follow the shape of the lung curve. The rCBF was studied accompanying cortical spreading depression in rat experiments to evaluate whether this phenomenon could explain the blood flow changes in migraine. (14C) iodoantipyrine was given as an intravenous bolus injection and the brain content of indicator was determined by tissue sample or autoradiography after 10 or 20 seconds of isotope circulation. The conditions of the autoradiographic methods are that the flow remains constant within the period of measuring, and that the region under study is homogenous with regard to flow and λ. (EG)

  3. Energy harvesting from arterial blood pressure for powering embedded brain sensors

    Science.gov (United States)

    Nanda, Aditya; Karami, M. Amin

    2016-04-01

    This paper investigates energy harvesting from arterial blood pressure via the piezoelectric effect by using a novel streaked cylinder geometry for the purpose of powering embedded micro-sensors in the brain. Initially, we look at the energy harvested by a piezoelectric cylinder placed inside an artery acted upon by blood pressure. Such an arrangement would be tantamount to constructing a stent out of piezoelectric materials. A stent is a cylinder placed in veins and arteries to prevent obstruction in blood flow. The governing equations of a conductor coated piezoelectric cylinder are obtained using Hamilton's principle. Pressure acting in arteries is radially directed and this is used to simplify the modal analysis and obtain the transfer function relating pressure to the induced voltage across the surface of the harvester. The power harvested by the cylindrical harvester is obtained for different shunt resistances. Radially directed pressure occurs elsewhere and we also look at harvesting energy from oil flow in pipelines. Although the energy harvested by the cylindrical energy harvester is significant at resonance, the natural frequency of the system is found to be very high. To decrease the natural frequency, we propose a novel streaked stent design by cutting it along the length, transforming it to a curved plate and decreasing the natural frequency. The governing equations corresponding to the new geometry are derived using Hamilton's principle and modal analysis is used to obtain the transfer function.

  4. MR blood velocity measurements in the pulmonary arteries with magnetic resonance imaging. Messung der Blutflussgeschwindigkeit in den Pulmonalarterien mit Hilfe der Magnetresonanztechnik

    Energy Technology Data Exchange (ETDEWEB)

    Gamroth, A.H.; Wacker, C.M.; Knopp, M.V.; Betsch, B.; Clorius, J.H.; Kaick, G. van (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Abt. fuer Onkologische Diagnostik und Therapie); Schad, L.R. (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Abt. fuer Biophysik und Medizinische Strahlenphysik); Gehling, U. (Thoraxklinik Heidelberg (Germany). Innere Medizin-Pneumologie)

    1992-04-01

    MR blood velocity measurements were performed by the RACE technique in a plane perpendicular to the flow of the pulmonary arteries. MR findings were correlated with those of perfusion scintigraphy, Doppler US and right heart catheter (thermodilution). The ratio of MR blood flow measurements of right and left pulmonary arteries correlated well with the results of perfusion scintigraphy (RPA to LPA) and Doppler. Poor correlation was found when comparing MR blood flow measurements with right heart catheter since absolute flow measurements can be superimposed by neighboring blood vessels in complex anatomic situations. (orig.).

  5. Assessment of maternal cerebral blood flow in patients with preeclampsia

    Directory of Open Access Journals (Sweden)

    Mandić Vesna

    2005-01-01

    Full Text Available Introduction Systemic vasoconstrktion in preeclamptic patients increases vascular resistance, and is manifested by increased arterial blood flow velocity. The aim of the study is to evaluate if there is a change of Doppler indices in maternal medial cerbral artery (MCA in severe preeclampsia due to: 1 severity of clinical symptoms, 2 the beginning of eclamptic attack and 3 the application of anticonvidsive therapy. Material and methods A prospective clinical study included 92 pregnant women, gestational age 28-36 weeks. They were divided into three groups: normotensive (n=30, mild preeclampsia (n=33, and severe preeclampsia (n=29. We investigated maternal cerebral circulation by assessing the MCA. We registrated: pulsatility index (Pi, resistance index (Ri, Systolic/diastolic ratio (S/D, and the maximum systolic, end diastolic and medium velocity. Patients with severe preeclampsia were divided into two subgroups: subgroup 1 included patients without symptoms of threatening eclampsia (n=18; 62.06%; while subgroup 2 included those with symptoms of preeclampsia (n=11; 37.94%. All patients with severe preeclampsia were treated with magnesium sulfate (MgSO4, and cerebral blood flow was measured before and after the treatment. Statistical analysis was done by oneway ANOVA, Student t-test and t-paired sample test. The difference was considered to be significant if p < 0.05. Results Significantly increased Pi, Ri and all velocities were established in the group of patients with severe preeclampsia compared with the other two groups. In the group with severe preeclamsia we registrated significantly increased values of all velocities (patients with signs of threatening eclampsia. After MgSO4 treatment in patients with severe preeclampsia significantly decreased values of Pi, Ri, S/D ratio and all velocities were registered. Discussion In the studied group of patients with severe preclampsia we found increased velocity values, Pi and Ri, especially in

  6. 21 CFR 870.4260 - Cardiopulmonary bypass arterial line blood filter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass arterial line blood filter... Cardiopulmonary bypass arterial line blood filter. (a) Identification. A cardiopulmonary bypass arterial line blood filter is a device used as part of a gas exchange (oxygenator) system to filter...

  7. The clinical study of cerebral blood flow imaging in patients with early syphilis

    International Nuclear Information System (INIS)

    Objective: To study the clinical value of cerebral blood flow imaging for evaluation of patients with early syphilis. Methods: Fifty-three patients with early syphilis underwent cerebral blood flow imaging using 99Tcm-ethylenecysteinate dimer(ECD). Regional cerebral blood flow (rCBF) changes were analyzed. Results: The acquired images of 53 patients were graded as 5 types. The rCBF was significantly depressed in 48 of 53 patients mainly in the areas dominated by anterior cerebral artery and middle cerebral artery. Conclusion: Treponema pallidum (TP) could start invading central nervous system at the early stage of infection

  8. Forearm blood flow responses to neuropeptide Y, noradrenaline and adenosine 5'-triphosphate in hypertensive and normotensive subjects

    DEFF Research Database (Denmark)

    Nilsson, T; Hrafnkelsdóttir, T; Edvinsson, L; Jern, S; Erlinge, D; Wall, U

    co-transmitters we studied the effects of intra-arterial infusion of NPY, NA and ATP on forearm blood flow. Blood flow was measured by venous occlusion plethysmography in six hypertensive (mean arterial blood pressure (MAP) 113 +/- 4 mmHg) and six matched normotensive subjects (MAP 97 +/- 3 mm......Hg). NPY and NA significantly reduced forearm blood flow, while a powerful increase was seen with ATP. Forearm vascular resistance, calculated as MAP divided by forearm blood flow, was significantly increased by NPY and NA and strongly reduced by ATP. There was no difference between hypertensive and...

  9. Aspects of the continuous clinical measurement of arterial blood pressure and cardiac output

    International Nuclear Information System (INIS)

    In this paper the authors try to classify circulatory measurements as to certain characteristics such as ''activeness'', ''invasivenesss'', etc. Next they turn to defining some fundamental measurements in the blood circulation and focus attention on the continuous measurement of systemic arterial pressure and flow to finally emphasize the inaccuracy of clinical cardiac output methods. The conclusion is that clinical circulatory measurement methods have accuracies at least an order of magnitude worse than common physical methods used in electrical or mechanical engineering. (Auth.)

  10. Flow analysis of the ophthalmic artery

    Energy Technology Data Exchange (ETDEWEB)

    Harada, Kuniaki; Hashimoto, Masato; Bandoh, Michio; Odawara, Yoshihiro; Kamagata, Masaki; Shirase, Ryuji [Sapporo Medical Univ. (Japan). Hospital

    2003-02-01

    The purpose of this study was to analyze the hemodynamics of ophthalmic artery flow using phase contrast MR angiography (PC-MRA). A total of 14 eyes from 10 normal volunteers and a patient with normal tension glaucoma (NTG) were analyzed. The optimal conditions were time repetition (TR)/echo time (TE)/flip angle (FA)/nex=40 ms/minimum/90 deg/2, field of view (FOV)=6 cm, matrix size=256 x 256. The resistive index (RI) and pulsatillity index (PI) values were significantly raised in the patient with NTG when compared to the control group. We therefore believe that PC-MRA may be a useful clinical tool for the assessment of the mechanism of NTG. (author)

  11. Flow analysis of the ophthalmic artery

    International Nuclear Information System (INIS)

    The purpose of this study was to analyze the hemodynamics of ophthalmic artery flow using phase contrast MR angiography (PC-MRA). A total of 14 eyes from 10 normal volunteers and a patient with normal tension glaucoma (NTG) were analyzed. The optimal conditions were time repetition (TR)/echo time (TE)/flip angle (FA)/nex=40 ms/minimum/90 deg/2, field of view (FOV)=6 cm, matrix size=256 x 256. The resistive index (RI) and pulsatillity index (PI) values were significantly raised in the patient with NTG when compared to the control group. We therefore believe that PC-MRA may be a useful clinical tool for the assessment of the mechanism of NTG. (author)

  12. Dynamic exercise enhances regional cerebral artery mean flow velocity

    DEFF Research Database (Denmark)

    Linkis, P; Jørgensen, L G; Olesen, H L;

    1995-01-01

    Dynamic exercise enhances regional cerebral artery mean flow velocity. J. Appl. Physiol. 78(1): 12-16, 1995.--Anterior (ACA) and middle (MCA) cerebral artery mean flow velocities (Vmean) and pulsatility indexes were determined using transcranial Doppler in 14 subjects during dynamic exercise afte...

  13. Numerical simulation of the blood flow behavior in the circle of Willis

    Directory of Open Access Journals (Sweden)

    Razavi Seyyed Esmail

    2014-06-01

    Full Text Available Introduction: This paper represents the numerical simulation of blood flow in the circle of Willis (CoW. Circle of Willis is responsible for the oxygenated blood distribution into the cerebral mass. To investigate the blood behavior, two Newtonian and non-Newtonian viscosity models were considered and the results were compared under steady state conditions. Methods: Methodologically, the arterial geometry was obtained using 3D magnetic resonance angiography (MRA data. The blood flow through the cerebral vasculature was considered to be steady and laminar, and the Galerkin’s finite element method was applied to solve the systems of non-linear Navier-Stokes equations. Results: Flow patterns including flow rates and shear rates were obtained through the simulation. The minimal magnitude of shear rates was much greater than 100 s-1 through the larger arteries; thus, the non-Newtonian blood viscosity tended to approach the constant limit of infinite shear viscosity through the CoW. So, in larger arteries the non-Newtonian nature of blood was less dominant and it would be treated as a Newtonian fluid. The only exception was the anterior communicating artery (ACoA in which the blood flow showed different behavior for the Newtonian and non-Newtonian cases. Conclusion: By comparing the results it was concluded that the Newtonian viscosity assumption of blood flow through the healthy, complete circle of Willis under the normal and steady conditions would be acceptably accurate.

  14. 21 CFR 870.2120 - Extravascular blood flow probe.

    Science.gov (United States)

    2010-04-01

    ... blood flow probe. (a) Identification. An extravascular blood flow probe is an extravascular ultrasonic or electromagnetic probe used in conjunction with a blood flowmeter to measure blood flow in...

  15. CFD simulation of blood flow inside the corkscrew collaterals of the Buerger’s disease

    OpenAIRE

    Sharifi, Alireza; Charjouei Moghadam, Mohammad

    2016-01-01

    Introduction: Buerger’s disease is an occlusive arterial disease that occurs mainly in medium and small vessels. This disease is associated with Tobacco usage. The existence of corkscrew collateral is one of the established characteristics of the Buerger’s disease. Methods: In this study, the computational fluid dynamics (CFD) simulation of blood flow within the corkscrew artery of the Buerger’s disease is conducted. The geometry of the artery is constructed based on the actual corkscrew arte...

  16. Inner ocular blood flow responses to an acute decrease in blood pressure in resting humans

    International Nuclear Information System (INIS)

    Whether inner ocular vessels have an autoregulatory response to acute fluctuations in blood pressure is unclear. We tried to examine the validity of acute hypotension elicited by thigh-cuff release as to assess the dynamic autoregulation in the ocular circulation. Blood flow velocity in the superior nasal and inferior temporal retinal arterioles, and in the retinal and choroidal vasculature were measured with the aid of laser speckle flowgraphy before and immediately after an acute decrease in blood pressure in 20 healthy subjects. Acute hypotension was induced by a rapid release of bilateral thigh occlusion cuffs that had been inflated to 220 mmHg for 2 min. The ratio of the relative change in retinal and choroidal blood flow velocity to the relative change in mean arterial blood pressure (MAP) was calculated. Immediately after cuff release, the MAP and blood flows in the all ocular target vessels decreased significantly from the baseline values obtained before thigh-cuff release. The ratio of the relative change in inner ocular blood flow velocity to that in the MAP exceeded 1% / %mmHg. An explicit dynamic autoregulation in inner ocular vessels cannot be demonstrated in response to an acute hypotension induced by the thigh-cuff release technique. (paper)

  17. Laminar blood flow in stenotic microchannels

    OpenAIRE

    Calejo, Joana A. C.; Garcia, Valdemar; Fernandes, Carla S.

    2015-01-01

    In this work, Newtonian and non-Newtonian laminar blood flow in rectangular microchannels with symmetric and asymmetric atheroma were numerically studied. It was observed that the impact of symmetry of the atheroma is almost negligible and the non-Newtonian properties of blood leads to higher pressure drops and wall shear stresses than the ones obtained for Newtonian flows.

  18. A Model of Anterograde Oxygenated Lung Blood Flow in Acardia.

    Science.gov (United States)

    Marinakis, Sotirios; Burki, Marco; Abdel-Sayed, Saad; von Segesser, Ludwig Karl

    2016-01-01

    In extreme situations such as hyperacute rejection of heart transplant or major heart trauma, heart explantation and extracorporeal membrane oxygenation (ECMO) hemodynamic support might be the only means for survival. In our previous model of acardia, pulmonary artery (PA) was clamped and did not receive any anterograde blood flow. A model of anterograde PA perfusion might be necessary to avoid ischemic pulmonary damage in prolonged ECMO in acardia. The aim of this study was to describe the surgical technique and to determine the feasibility of an anterograde lung perfusion in acardia through the anastomosis of the right internal mammary artery (RIMA) to the PA. A venoarterial cardiopulmonary bypass was established in three pigs (72 ± 2.6 kg) by the transjugular insertion to the caval axis of a double-staged cannula with carotid artery return. Heart was excised and ECMO was established as previously reported. Right internal mammary artery was harvested and after measurement of its output (93.3 ± 5.8 ml/min, representing 2.17% ± 0.15% of total pump flow), it was anastomosed to PA. Right internal mammary artery anastomosis to PA is a feasible, safe, and easy to perform maneuver assuring an anterograde lung perfusion in acardia. PMID:27442854

  19. Normal reference values for vertebral artery flow volume by color Doppler sonography in Korean adults

    International Nuclear Information System (INIS)

    Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 ± 39.7 ml/min for the right side and 127.6 ± 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 ± 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 ± 59.19 ml/min in male, and 217.28 ± 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.

  20. The measurement of blood speed in the pulmonary artery trunk

    International Nuclear Information System (INIS)

    The paper describes a non invasive methodology for the measurement of blood speed in the pulmonary artery trunk. The methodology has been tested with a moving radioactive tracer (nuclear medicine). An image processing technique is proposed, for detection and analysis of a moving object with variable shape and intensity over time (radioactive bolus). Experiments on the application of the technique in nuclear medicine are critically analysed. (authors)

  1. Subcutaneous blood flow in psoriasis

    International Nuclear Information System (INIS)

    The simultaneously recorded disappearance rates of 133xe from subcutaneous adipose tissue in the crus were studied in 10 patients with psoriasis vulgaris using atraumatic labeling of the tissue in lesional skin (LS) areas and symmetrical, nonlesional skin (NLS) areas. Control experiments were performed bilaterally in 10 younger, healthy subjects. The subcutaneous washout rate constant was significantly higher in LS, 0.79 +/- 0.05 min-1 x 10(2) compared to the washout rate constant of NLS, 0.56 +/- 0.07 min-1. 10(2), or the washout rate constant in the normal subjects, 0.46 +/- 0.17 min-1 x 10(2). The mean washout rate constant in NLS was 25% higher than the mean washout rate constant in the normal subjects. The difference was, however, not statistically significant. Differences in the washout rate constants might be due to abnormal subcutaneous tissue-to-blood partition (lambda) in the LS--and therefore not reflecting the real differences in the subcutaneous blood flow (SBF). The lambda for 133Xe was therefore measured--using a double isotope washout method (133Xe and [131I]antipyrine)--in symmetrical sites of the lateral crus in LS and NLS of 10 patients with psoriasis vulgaris and in 10 legs of normal subjects. In LS the lambda was 4.52 +/- 1.67 ml/g, which was not statistically different from that of NLS, 5.25 +/- 2.19 ml/g, nor from that of normal subcutaneous tissue, 4.98 +/- 1.04 ml/g. Calculations of the SBF using the obtained lambda values gave a significantly higher SBF in LS, 3.57 +/- 0.23 ml/100 g/min, compared to SBF in the NLS, 2.94 +/- 0.37 ml/100 g/min. There was no statistically significant difference between SBF in NLS and SBF in the normal subjects. The increased SBF in LS of psoriatics might be a secondary phenomenon to an increased heat loss in the lesional skin

  2. Scintigraphic and echocardiographic evaluation of pulmonary flow after percutaneous closure of patent arterial duct

    International Nuclear Information System (INIS)

    Introduction: During the evolution of patients submitted to percutaneous closure of a patent arterial duct (PAD), some degree of protrusion of the occlusive device into the left pulmonary arterial branch has been described. Aim: We tested the hypothesis that patients (pts) with device protrusion have also decreased pulmonary blood perfusion. Material and Methods: We studied 70 pts submitted to percutaneous closure of the PAD with Gianturco coils (mean age: 8.6, median: 7.5 years), with a mean time follow-up of 55 months. Comprehensive Doppler echocardiographic studies were performed. We calculated the percentage of difference of blood flow velocities between the left and right pulmonary arterial branches. Pulmonary scintigraphy was performed using an intravenous injection of 99mTc labeled human albumin macroaggregates to evaluate bilateral lung perfusion ( relative quantification ). The same determinations were performed in 22 controls. Results: 66 pts (94,3%) showed some degree of protrusion of the device into the left pulmonary artery. Patients were grouped according to the difference in the percentage of flow velocity between arterial branches as detected by Doppler: ≥ 30% (16 pts, group A); < 30% (54 pts, group B) and controls (22 pts, group C). The mean value of left lung perfusion was significantly lower in group A (41.9% ± 3,2%), compared to group B (46.8% ± 1,93 %) and to group C (46,8% ± 2,4%) (Kruskal-Wallis, p<0.001). There was a significant negative linear correlation between the values of left lung perfusion and the percentage difference of blood flow velocities. Conclusion: Protrusion of the occlusive device in pts with PAD is not always associated to pulmonary artery obstruction. However, pts showing blood flow acceleration ≥30% at the left pulmonary arterial branch by Doppler have significantly lower values of lung perfusion

  3. The Physics of Coronary Blood Flow

    CERN Document Server

    Zamir, M

    2005-01-01

    Coronary blood flow is blood flow to the heart for its own metabolic needs. In the most common form of heart disease there is a disruption in this flow because of obstructive disease in the vessels that carry the flow. The subject of coronary blood flow is therefore associated mostly with the pathophysiology of this disease, rarely with dynamics or physics. Yet, the system responsible for coronary blood flow, namely the "coronary circulation," is a highly sophisticated dynamical system in which the dynamics and physics of the flow are as important as the integrity of the conducting vessels. While an obstruction in the conducting vessels is a fairly obvious and clearly visible cause of disruption in coronary blood flow, any discord in the complex dynamics of the system can cause an equally grave, though less conspicuous, disruption in the flow. This book is devoted specifically to the dynamics and physics of coronary blood flow. While relevance to the clinical and pathophysiological issues is clearly maintaine...

  4. Dynamic modeling of renal blood flow in Dahl hypertensive and normotensive rats

    DEFF Research Database (Denmark)

    Knudsen, Torben; Elmer, Henrik; Knudsen, Morten H; Stoustrup, Jakob; Holstein-Rathlou, N.-H.

    2004-01-01

    A method is proposed in this paper which allows characterization of renal autoregulatory dynamics and efficiency using quantitative mathematical methods. Based on data from rat experiments, where arterial blood pressure and renal blood flow are measured, a quantitative model for renal blood flow ...... describe myogenic responses and tubuloglomerular feedback responses separately. The method is applied to data from normo- and hypertensive Dahl rats, and a discriminator that separates data from normotensive Dahl R rats and hypertensive Dahl S rats is constructed....

  5. Influence of 5-hydroxytryptamine (serotonin) on blood flow in the dog pulp

    International Nuclear Information System (INIS)

    The effect of intra-arterial injection of 5-hydroxytryptamine (5-HT) on pulpal blood flow of the dog was determined using the 15-micron radioisotope-labeled microsphere injection method. Pulpal blood flow was significantly reduced following the 5-HT injection. This decrease in blood flow appeared to be due to vasoconstriction as determined by an increase in pulpal vascular hindrance. However, our findings do not preclude the possibility that blood flow was reduced as a result of passive compression of venules produced by vasodilation in a low-compliance environment

  6. Topical menthol increases cutaneous blood flow.

    Science.gov (United States)

    Craighead, Daniel H; Alexander, Lacy M

    2016-09-01

    Menthol, the active ingredient in several topically applied analgesics, activates transient receptor potential melastatin 8 (TRPM8) receptors on sensory nerves and on the vasculature inducing a cooling sensation on the skin. Ilex paraguariensis is also a common ingredient in topical analgesics that has potential vasoactive properties and may alter the mechanisms of action of menthol. We sought to characterize the microvascular effects of topical menthol and ilex application and to determine the mechanism(s) through which these compounds may independently and combined alter cutaneous blood flow. We hypothesized that menthol would induce vasoconstriction and that ilex would not alter skin blood flow (SkBF). Three separate protocols were conducted to examine menthol and ilex-mediated changes in SkBF. In protocol 1, placebo, 4% menthol, 0.7% ilex, and combination menthol+ilex gels were applied separately to the skin and red cell flux was continuously measured utilizing laser speckle contrast imaging (LSCI). In protocol 2, seven concentrations of menthol gel (0.04%, 0.4%, 1%, 2%, 4%, 7%, 8%) were applied to the skin to model the dose-response curve. In protocol 3, placebo, menthol, ilex, and menthol+ilex gels were applied to skin under local thermal control (34°C) both with and without sensory nerve blockage (topical lidocaine 4%). Post-occlusive reactive hyperemia (PORH) and local heating (42°C) protocols were conducted to determine the relative contribution of endothelium derived hyperpolarizing factors (EDHFs)/sensory nerves and nitric oxide (NO), respectively. Red cell flux was normalized to mean arterial pressure expressed as cutaneous vascular conductance (CVC: flux·mmHg(-1)) in all protocols. Topical menthol application increased SkBF compared to placebo (3.41±0.33 vs 1.1±0.19CVC: peffect, p<0.05) with an ED50 of 1.0%. Similarly, SkBF was increased after menthol application during PORH (3.62±0.29 vs. 2.50±0.21flux·mmHg(-1); p<0.001), but not local heating

  7. Influence of Gravity on Blood Volume and Flow Distribution

    Science.gov (United States)

    Pendergast, D.; Olszowka, A.; Bednarczyk, E.; Shykoff, B.; Farhi, L.

    1999-01-01

    increased and if there is edema in space. Anecdotal evidence suggests there may be cerebral edema early in flight. Cerebral artery velocity has been shown to be elevated in simulated microgravity. The elevated cerebral artery velocity during simulated microgravity may reflect vasoconstriction of the arteries and not increased cerebral blood flow. The purpose of our investigations was to evaluate the effects of alterations in simulated gravity (+/-), resulting in changes in cardiac output (+/-), and on the blood flow and volume distribution in the lung and brain of human subjects. The first hypothesis of these studies was that blood flow and volume would be affected by gravity, but their distribution in the lung would be independent of gravity and due to vasoactivity changing vascular resistance in lung vessels. The vasodilitation of the lung vasculature (lower resistance) along with increased "compliance" of the heart could account for the absence of increased central venous pressure in microgravity. Secondly, we postulate that cerebral blood velocity is increased in microgravity due to large artery vasoconstriction, but that cerebral blood flow would be reduced due to autoregulation.

  8. Pulsatile flow of shear-dependent fluid in a stenosed artery

    Directory of Open Access Journals (Sweden)

    Mandal Shankar Mani

    2012-01-01

    Full Text Available This paper aims to investigate the blood flow in a bell-shaped constricted rigid tube, modeled as stenosed artery. The flow is assumed to be axi-symmetric, laminar and of oscillatory type. A mathematical model of shear-thinning fluid corresponding to the shear-dependent blood viscosity (mainly due to the behavior of the red blood cells in suspension of the flowing blood is considered. The governing equations of motion are presented with the help of stream function-vorticity and are solved numerically by finite-difference technique. The shear-thinning fluid model for the flowing blood has significant contribution in the dynamics of oscillatory blood flow. The results reveal that the arterial wall shear stress reduced significantly and the peak value of the wall shear stress at the maximum area reduction is comparatively low for Newtonian fluid viscosity. The lengths of recirculating regions formed after the constriction are reduced for the shear-thinning blood viscosity model and also for its different material parameters.

  9. One dimensional blood flow in a planetocentric orbit

    Science.gov (United States)

    Haranas, Ioannis; Gkigkitzis, Ioannis

    2012-05-01

    All life on earth is accustomed to the presence of gravity. When gravity is altered, biological processes can go awry. It is of great importance to ensure safety during a spaceflight. Long term exposure to microgravity can trigger detrimental physiological responses in the human body. Fluid redistribution coupled with fluid loss is one of the effects. In particular, in microgravity blood volume is shifted towards the thorax and head. Sympathetic nervous system-induced vasoconstriction is needed to maintain arterial pressure, while venoconstriction limits venous pooling of blood prevents further reductions in venous return of blood to the heart. In this paper, we modify an existing one dimensional blood flow model with the inclusion of the hydrostatic pressure gradient that further depends on the gravitational field modified by the oblateness and rotation of the Earth. We find that the velocity of the blood flow VB is inversely proportional to the blood specific volume d, also proportional to the oblateness harmonic coefficient J2, the angular velocity of the Earth ωE, and finally proportional to an arbitrary constant c. For c = -0.39073 and ξH = -0.5 mmHg, all orbits result to less blood flow velocities than that calculated on the surface of the Earth. From all considered orbits, elliptical polar orbit of eccentricity e = 0.2 exhibit the largest flow velocity VB = 1.031 m/s, followed by the orbits of inclination i = 45°and 0°. The Earth's oblateness and its rotation contribute a 0.7% difference to the blood flow velocity.

  10. Quantification of complex blood flow using real-time in vivo vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Haugaard, Per;

    2010-01-01

    A quantitative method for distinguishing complex from non-complex flow patterns in ultrasound is presented. A new commercial BK Medical ultrasound scanner uses the Transverse Oscillation vector flow technique for visualising flow patterns in real-time. In vivo vector flow data of the blood flow...... ultrasound. From the same data the mean standard deviation of the flow angles (MSTDA) were calculated and compared to the expert evaluations. Comparison between the combined experts evaluations and the MSTDA was performed. Using linear regression analysis, a correlation coefficient of 0.925 was found....... The upper and lower bounds for a 95% confidence interval of 0.974 and 0.792 respectively, were calculated. The MSTDA was below 25 for the common carotid artery and above 25 for the carotid bulb. Thus, the MSTDA value can distinguishing complex flow from non-complex flow and can be used as the basis...

  11. Time-resolved PIV measurements of the flow field in a stenosed, compliant arterial model

    Science.gov (United States)

    Geoghegan, P. H.; Buchmann, N. A.; Soria, J.; Jermy, M. C.

    2013-05-01

    Compliant (flexible) structures play an important role in several biological flows including the lungs, heart and arteries. Coronary heart disease is caused by a constriction in the artery due to a build-up of atherosclerotic plaque. This plaque is also of major concern in the carotid artery which supplies blood to the brain. Blood flow within these arteries is strongly influenced by the movement of the wall. To study these problems experimentally in vitro, especially using flow visualisation techniques, can be expensive due to the high-intensity and high-repetition rate light sources required. In this work, time-resolved particle image velocimetry using a relatively low-cost light-emitting diode illumination system was applied to the study of a compliant flow phantom representing a stenosed (constricted) carotid artery experiencing a physiologically realistic flow wave. Dynamic similarity between in vivo and in vitro conditions was ensured in phantom construction by matching the distensibility and the elastic wave propagation wavelength and in the fluid system through matching Reynolds ( Re) and Womersley number ( α) with a maximum, minimum and mean Re of 939, 379 and 632, respectively, and a α of 4.54. The stenosis had a symmetric constriction of 50 % by diameter (75 % by area). Once the flow rate reached a critical value, Kelvin-Helmholtz instabilities were observed to occur in the shear layer between the main jet exiting the stenosis and a reverse flow region that occurred at a radial distance of 0.34 D from the axis of symmetry in the region on interest 0-2.5 D longitudinally downstream from the stenosis exit. The instability had an axis-symmetric nature, but as peak flow rate was approached this symmetry breaks down producing instability in the flow field. The characteristics of the vortex train were sensitive not only to the instantaneous flow rate, but also to whether the flow was accelerating or decelerating globally.

  12. A reconstruction method for gappy and noisy arterial flow data.

    Science.gov (United States)

    Yakhot, Alexander; Anor, Tomer; Karniadakis, George Em

    2007-12-01

    Proper orthogonal decomposition (POD), Kriging interpolation, and smoothing are applied to reconstruct gappy and noisy data of blood flow in a carotid artery. While we have applied these techniques to clinical data, in this paper in order to rigorously evaluate their effectiveness we rely on data obtained by computational fluid dynamics (CFD). Specifically, gappy data sets are generated by removing nodal values from high-resolution 3-D CFD data (at random or in a fixed area) while noisy data sets are formed by superimposing speckle noise on the CFD results. A combined POD-Kriging procedure is applied to planar data sets mimicking coarse resolution "ultrasound-like" blood flow images. A method for locating the vessel wall boundary and for calculating the wall shear stress (WSS) is also proposed. The results show good agreement with the original CFD data. The combined POD-Kriging method, enhanced by proper smoothing if needed, holds great potential in dealing effectively with gappy and noisy data reconstruction of in vivo velocity measurements based on color Doppler ultrasound (CDUS) imaging or magnetic resonance angiography (MRA). PMID:18092738

  13. Study of blood flow parameters in a phantom by magnetic resonance imaging MRI

    OpenAIRE

    Καζέρου, Ασπασία

    2012-01-01

    The study of pulsatile flow through a stenosis is motivated by the need to obtain a better understanding of the impact of flow phenomena on atherosclerosis and stroke. MRI techniques have been employed to characterize flow emerging from a stenosis and non-stenotic tube. Detection and quantification of stenosis, serve as the basis for surgical intervention. In the future, the study of arterial blood flow will lead to the prediction of individual hemodynamic flows in any patient, th...

  14. Modeling study of terminal transients of blood flow

    Science.gov (United States)

    Stiukhina, Elena S.; Postnov, Dmitry E.

    2016-04-01

    In spite of growing body of experimental and theoretical results on blood flow (BF) patterns under the continuously sustained circulation, much less is known about BF dynamics under the exceptional, but still important cases of venous or arterial occlusion used in medical probes. Since these conditions finally lead to complete or nearly complete stop of red blood cells (RBC) motion, we term it as TTBF, being the Terminal Transients of Blood Flow. An extreme case of such transients is the ultimate extinction of BF after the stopping of heart contractions, during which it is governed by gravitation, some vascular-originated propulsion mechanisms, and, possibly, by RBC aggregation. Quite little is known about this process, while reports the detectable post-mortal motion of mice RBC during at least 2 hours. In our work we present the modeling study of TTBF patterns due to gravitational forces. We present the minimalistic model configuration of vasculature in order to simulate what happens immediately after the pumping of blood has been stopped. Our main findings are concerned to reversal of arterial BF, as well as to duration and non-monotonicity of transients.

  15. Value of Acceleration Flow in the Left Anterior Descending Coronary Artery for the Detection of Coronary Artery Stenosis by Transthoracic Coronary Color Doppler Echocardiography

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Whether the localized flow acceleration occurs in the resting stenotic left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated.Blood flow in the left anterior descending coronary arteries in 45 patients was detected by transthoracic color Doppler echocardiograph and multipoint pulse Doppler spectrums were recorded in the same segment. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was calculated. The ratio ≥1.5 was the cutoff value for the presence of localized acceleration flow.There were 23 patients with localized acceleration flow examined by echocardiography. Twenty of them were found to have luminal diameter stenosis (60 %- 98 %) in the left anterior descending coronary arteries by coronary angiography and 3 patients were normal. There were 22 patients without localized acceleration flow examined by echocardiography. Eighteen of them had no or <60% stenosis. Four patients had serious stenosis (≥95 %) or occluded segments in the left anterior descending coronary arteries on coronary angiography. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was significantly higher in patients with left anterior descending coronary artery stenosis than that in those without stenosis (1.9±0.3 vs 1.3±0.2, P<0.01) and it correlated significantly with left anterior descending coronary artery stenosis (r=0.77, P<0.01). The specificity by using the ratio≥1.5 for stenosis detection was 85.7 % (18/21), and the sensitivity was 83.3 % (20/24). This study demonstrated that local blood flow velocity was increased in the resting stenotic left anterior descending coronary artery. Transthoracic color Doppler echocardiography is a reliable noninvasive method to detect localized acceleration flow in the left anterior descending coronary artery stenosis and it is useful in the noninvasive diagnosis of stenosis in the left anterior descending

  16. Lipiodol-TAE and hepatic blood flow in radiation hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Azuma, Kazuyoshi; Hirokawa, Yutaka; Fukuoka, Haruhito (Hiroshima Univ. (Japan). School of Medicine) (and others)

    1991-06-01

    A 58-year-old man with biliary tract cancer associated with obstructive jaundice was treated with radiation therapy. The area encompassing the common bile duct and the porta hepatis was irradiated with 2 Gy per fraction to a total dose of 40 Gy. One day after the completion of irradiation, Lipiodol-transcatheter arterial embolization (Lipiodol-TAE) was performed. The irradiated field was seen as contrast media accumulation on hepatic arteriography and as defect shadow on superior mesenteric arteriography. Retention of Lipiodol, injected from the hepatic artery, was not seen in the irradiated field. Hepatic parenchyma exposed to irradiation was shown as low density area on CT performed 28 days after Lipiodol-TAE. The irradiated field was gradually enhanced on serial CT scans, and was seen as high density area on delayed scans. These radiologic appearances lead to the diagnosis of radiation hepatitis in this patient. A review of the literature, in addition to these findings, revealed that sinusoid blood flow in radiation hepatitis is delayed, depending on arterial blood, and that peribiliary plexus is strongly involved in hemodynamics of arterially injected Lipiodol. (N.K.).

  17. Problems in cerebral blood flow calculation using xenon-133 in patients with pulmonary diseases

    International Nuclear Information System (INIS)

    We used the end-tidal concentration of xenon-133 (air curve) to estimate the profile of its arterial concentration in calculating cerebral blood flow. We examined the effects of pulmonary disease and artificial ventilation on the air curve and the calculated cerebral blood flow. We studied the relation between arterial and end-tidal xenon activities in 19 subjects, of whom 15 had pulmonary dysfunction. The t 1/2 of the declining phases of the arterial and air curves were used to express their shapes. The mean +/- SD reference t 1/2 from 15 normal volunteers was 26.8 +/- 8.4 seconds. The mean +/- SD t 1/2 s of the air and arterial curves from the 15 patients with pulmonary dysfunction were 10.4 +/- 2.9 and 33.8 +/- 10.9 seconds. The degree of pulmonary dysfunction (expressed as the pulmonary shunt percentage) correlated with distortion of the air curve. Substituting the arterial for the air curve, mean calculated cerebral blood flow (as the initial slope index) increased from 40 to 61 for the 12 patients with chronic obstructive pulmonary disease. The degree of underestimation of cerebral blood flow using the air curve correlated with the pulmonary shunt percentage. Our work confirms the problems of estimating cerebral blood flow in subjects with pulmonary dysfunction

  18. Flow-Induced Changes in Dimensions and Mechanical Properties of Rabbit Common Carotid Arteries

    Science.gov (United States)

    Matsumoto, Takeo; Okumura, Eijiro; Shirono, Takahiro; Sho, Eiketsu; Masuda, Hirotake; Sato, Masaaki

    Flow-induced changes in dimensions and mechanical properties of blood vessel wall were studied in the rabbit left common carotid arteries connected directly to the left external jugular vein via an arteriovenous fistula (AVF) to increase its blood flow by >10-fold for 4 weeks. Contralateral artery was used as control. We found significant increase not only in diameter, but also in thickness and length of unloaded artery exposed to increased flow, indicating the increase in wall volume. The increase in diameter and thickness but not in longitudinal length correlated significantly with the volumetric increase of the wall. Pressure-imposed test showed that the wall became less distensible in response to flow increase. Fluid shear stress estimated for physiological condition was significantly higher in AVF side than control, indicating that 10-fold increase in flow was not compensated in 4 weeks. Circumferential strain in a physiological pressure range was significantly lower in AVF side, while hoop stress was similar in both sides. These results may indicate that circumferential stress but not strain is maintained constant, and longitudinal change is not regulated in flow-imposed arteries.

  19. Frequency encoding in renal blood flow regulation

    DEFF Research Database (Denmark)

    Marsh, Donald J; Sosnovtseva, Olga; Pavlov, Alexey N;

    2005-01-01

    With a model of renal blood flow regulation, we examined consequences of tubuloglomerular feedback (TGF) coupling to the myogenic mechanism via voltage-gated Ca channels. The model reproduces the characteristic oscillations of the two mechanisms and predicts frequency and amplitude modulation of...... the myogenic oscillation by TGF. Analysis by wavelet transforms of single-nephron blood flow confirms that both amplitude and frequency of the myogenic oscillation are modulated by TGF. We developed a double-wavelet transform technique to estimate modulation frequency. Median value of the ratio of...... from one TGF cycle to the next. We used a blood pressure signal recorded by telemetry from a conscious rat as the input to the model. Blood pressure fluctuations induced variability in the modulation records similar to those found in the nephron blood flow results. Frequency and amplitude modulation...

  20. Adipose tissue and skeletal muscle blood flow during mental stress

    International Nuclear Information System (INIS)

    Mental stress [a modified Stroop color word conflict test (CWT)] increased adipose tissue blood flow (ATBF; 133Xe clearance) by 70% and reduced adipose tissue vascular resistance (ATR) by 25% in healthy male volunteers. The vasculatures of adipose tissue (abdomen as well as thigh), skeletal muscle of the calf (133Xe clearance), and the entire calf (venous occlusion plethysmography) responded similarly. Arterial epinephrine (Epi) and glycerol levels were approximately doubled by stress. Beta-Blockade by metoprolol (beta 1-selective) or propranolol (nonselective) attenuated CWT-induced tachycardia similarly. Metoprolol attenuated stress-induced vasodilation in the calf and tended to do so in adipose tissue. Propranolol abolished vasodilation in the calf and resulted in vasoconstriction during CWT in adipose tissue. Decreases in ATR, but not in skeletal muscle or calf vascular resistances, were correlated to increases in arterial plasma glycerol (r = -0.42, P less than 0.05), whereas decreases in skeletal muscle and calf vascular resistances, but not in ATR, were correlated to increases in arterial Epi levels (r = -0.69, P less than 0.01; and r = -0.43, P less than 0.05, respectively). The results suggest that mental stress increases nutritive blood flow in adipose tissue and skeletal muscle considerably, both through the elevation of perfusion pressure and via vasodilatation. Withdrawal of vasoconstrictor nerve activity, vascular beta 2-adrenoceptor stimulation by circulating Epi, and metabolic mechanisms (in adipose tissue) may contribute to the vasodilatation

  1. Adipose tissue and skeletal muscle blood flow during mental stress

    Energy Technology Data Exchange (ETDEWEB)

    Linde, B.; Hjemdahl, P.; Freyschuss, U.; Juhlin-Dannfelt, A.

    1989-01-01

    Mental stress (a modified Stroop color word conflict test (CWT)) increased adipose tissue blood flow (ATBF; 133Xe clearance) by 70% and reduced adipose tissue vascular resistance (ATR) by 25% in healthy male volunteers. The vasculatures of adipose tissue (abdomen as well as thigh), skeletal muscle of the calf (133Xe clearance), and the entire calf (venous occlusion plethysmography) responded similarly. Arterial epinephrine (Epi) and glycerol levels were approximately doubled by stress. Beta-Blockade by metoprolol (beta 1-selective) or propranolol (nonselective) attenuated CWT-induced tachycardia similarly. Metoprolol attenuated stress-induced vasodilation in the calf and tended to do so in adipose tissue. Propranolol abolished vasodilation in the calf and resulted in vasoconstriction during CWT in adipose tissue. Decreases in ATR, but not in skeletal muscle or calf vascular resistances, were correlated to increases in arterial plasma glycerol (r = -0.42, P less than 0.05), whereas decreases in skeletal muscle and calf vascular resistances, but not in ATR, were correlated to increases in arterial Epi levels (r = -0.69, P less than 0.01; and r = -0.43, P less than 0.05, respectively). The results suggest that mental stress increases nutritive blood flow in adipose tissue and skeletal muscle considerably, both through the elevation of perfusion pressure and via vasodilatation. Withdrawal of vasoconstrictor nerve activity, vascular beta 2-adrenoceptor stimulation by circulating Epi, and metabolic mechanisms (in adipose tissue) may contribute to the vasodilatation.

  2. Hyperemic flow heterogeneity within the calf, foot, and forearm measured with continuous arterial spin labeling MRI

    OpenAIRE

    Wu, Wen-Chau; Wang, Jiongjiong; Detre, John A.; Wehrli, Felix W.; Mohler, Emile; Ratcliffe, Sarah J.; Floyd, Thomas F

    2008-01-01

    Arterial spin labeling (ASL) is a noninvasive magnetic resonance imaging (MRI) technique for microvascular blood flow measurement. We used a continuous ASL scheme (CASL) to investigate the hyperemic flow difference between major muscle groups in human extremities. Twenty-four healthy subjects with no evidence of vascular disease were recruited. MRI was conducted on a 3.0 Tesla Siemens Trio whole body system with a transmit/receive knee coil. A nonmagnetic orthopedic tourniquet system was used...

  3. Placental blood flow measurements with radioisotopes in the pregnant guinea pig

    International Nuclear Information System (INIS)

    In 15 pregnant guinea pigs near term the blood flow (BF) of the myometrium and the placenta as well as the cardiac output were measured with 99Tcsup(m)-labelled microspheres. In front of one placenta the clearance of 133Xe was estimated in the same animal. For the 133Xe measurement a theoretical concept is presented. The mean placental BF is 105ml/(minx100g)(SD:84) for 99Tcsup(m) and 244(SD:80)ml/(minx100g) for 133Xe. The difference in both flow values is assumed to be related to foetal placental BF. The placental blood flow is also related to the location of the placenta in the uterine horn. The ratio of myometrial blood flow to placental blood flow decreased with an increase in the mean arterial blood pressure. The measurements are a preliminary report of an attempt to compare two different methods in measuring placental blood flow. (author)

  4. Radioisotope penile plethysmography: Technique for evaluating corpora cavernosal blood flow during early tumescence in patients with erectile dysfunction

    International Nuclear Information System (INIS)

    Radioisotope penile plethysmography is a new adaptation of technetium-labeled red blood cell imaging. It is designed to assess penile corpora cavernosal blood flow during early tumescence in patients with erectile dysfunction. Peak corporal flow rates and volume changes in the penis were analyzed and compared with arterial integrity (arteriography) and venous-sinusoidal competence (cavernosometry). Peak corporal flow rates correlated most accurately with arterial integrity (r =.01). No significant correlation was identified with venous leakage variables (r =.01) The significant correlation of peak corporal flow and arteriography suggests that radioisotope penile plethysmography may assist in the evaluation of arterial inflow disorders in patients with erectile dysfunction

  5. Measurement of bone blood flow in sheep

    International Nuclear Information System (INIS)

    Bone blood flow in sheep tibia has been estimated via the measurement of the perfusion limited clearance of 41Ar from the bone mineral matrix following fast neutron activation of 44Ca. Tibia blood flows were estimated for the intact sheep, and after the installation of an intramedullary pressure tap to elevate bone marrow pressure by saline infusion. The results indicate that normal blood flow in the tibia is in the range of 1.1 to 3.7 ml/100ml-min in the intact animal and at normal marrow pressure. With an elevated intramedullary pressure of approximately 100 mmHg, the bone blood flow measured varied around 0.5 to 1.1 ml/100ml-min. 12 refs., 5 figs., 1 tab

  6. Clinical relevance of intermittent tumour blood flow

    International Nuclear Information System (INIS)

    One of the goals of translational cancer research is to understand basic 'phenomena' so that tumour response to therapy can be improved. One such phenomenon is intermittent tumour blood flow. The impact of the transient hypoxia that results from decreased tumour blood flow is now beginning to be appreciated in preclinical systems, and also receiving some attention in clinical practise. Thus in this article we review the nature and frequency of microregional blood flow changes in preclinical and clinical tumours and examine the impact of those changes on response to both radiotherapy and chemotherapy. Additionally, the implications of non-constant blood flow for both the growth of the unperturbed tumour and the regrowth of surviving tumour clonogens during and after therapy are examined

  7. Mammary blood flow and nutrient uptake

    OpenAIRE

    Farmer, Chantal; Trottier, N.L.; Dourmad, Jean-Yves

    2015-01-01

    Sow milk is the major source of nutrients for suckling piglets and taking into account the large litter sizes of our current sow genotypes, it is imperative to maximize nutrient use by the mammary gland. The amount of nutrients available to mammary tissue is dependent upon the concentrations of nutrients in blood and the rate of its flow to the lactating glands. Nutrient availability to the udder may be estimated by measuring mammary arteriovenous differences, and mammary blood flow can be me...

  8. Retinal blood flow in diabetic retinopathy.

    OpenAIRE

    Patel, V.; Rassam, S; NEWSOM, R.; Wiek, J; Kohner, E.

    1992-01-01

    OBJECTIVES--(a) To report on the basic parameters of retinal blood flow in a population of diabetic patients with and without retinopathy and non-diabetic controls; (b) to formulate a haemodynamic model for the pathogenesis of diabetic retinopathy from this and other studies. DESIGN--Laser-Doppler velocimetry and computerised image analysis to determine retinal blood flow in a large cross sectional study. SETTING--Diabetic retinopathy outpatient clinic. SUBJECTS--24 non-diabetic controls and ...

  9. Cerebral blood flow links insulin resistance and baroreflex sensitivity.

    Science.gov (United States)

    Ryan, John P; Sheu, Lei K; Verstynen, Timothy D; Onyewuenyi, Ikechukwu C; Gianaros, Peter J

    2013-01-01

    Insulin resistance confers risk for diabetes mellitus and associates with a reduced capacity of the arterial baroreflex to regulate blood pressure. Importantly, several brain regions that comprise the central autonomic network, which controls the baroreflex, are also sensitive to the neuromodulatory effects of insulin. However, it is unknown whether peripheral insulin resistance relates to activity within central autonomic network regions, which may in turn relate to reduced baroreflex regulation. Accordingly, we tested whether resting cerebral blood flow within central autonomic regions statistically mediated the relationship between insulin resistance and an indirect indicator of baroreflex regulation; namely, baroreflex sensitivity. Subjects were 92 community-dwelling adults free of confounding medical illnesses (48 men, 30-50 years old) who completed protocols to assess fasting insulin and glucose levels, resting baroreflex sensitivity, and resting cerebral blood flow. Baroreflex sensitivity was quantified by measuring the magnitude of spontaneous and sequential associations between beat-by-beat systolic blood pressure and heart rate changes. Individuals with greater insulin resistance, as measured by the homeostatic model assessment, exhibited reduced baroreflex sensitivity (b = -0.16, p mediated by cerebral blood flow in central autonomic regions, including the insula and cingulate cortex (mediation coefficients < -0.06, p-values < .01). Activity within the central autonomic network may link insulin resistance to reduced baroreflex sensitivity. Our observations may help to characterize the neural pathways by which insulin resistance, and possibly diabetes mellitus, relates to adverse cardiovascular outcomes. PMID:24358272

  10. Cerebral blood flow links insulin resistance and baroreflex sensitivity.

    Directory of Open Access Journals (Sweden)

    John P Ryan

    Full Text Available Insulin resistance confers risk for diabetes mellitus and associates with a reduced capacity of the arterial baroreflex to regulate blood pressure. Importantly, several brain regions that comprise the central autonomic network, which controls the baroreflex, are also sensitive to the neuromodulatory effects of insulin. However, it is unknown whether peripheral insulin resistance relates to activity within central autonomic network regions, which may in turn relate to reduced baroreflex regulation. Accordingly, we tested whether resting cerebral blood flow within central autonomic regions statistically mediated the relationship between insulin resistance and an indirect indicator of baroreflex regulation; namely, baroreflex sensitivity. Subjects were 92 community-dwelling adults free of confounding medical illnesses (48 men, 30-50 years old who completed protocols to assess fasting insulin and glucose levels, resting baroreflex sensitivity, and resting cerebral blood flow. Baroreflex sensitivity was quantified by measuring the magnitude of spontaneous and sequential associations between beat-by-beat systolic blood pressure and heart rate changes. Individuals with greater insulin resistance, as measured by the homeostatic model assessment, exhibited reduced baroreflex sensitivity (b = -0.16, p < .05. Moreover, the relationship between insulin resistance and baroreflex sensitivity was statistically mediated by cerebral blood flow in central autonomic regions, including the insula and cingulate cortex (mediation coefficients < -0.06, p-values < .01. Activity within the central autonomic network may link insulin resistance to reduced baroreflex sensitivity. Our observations may help to characterize the neural pathways by which insulin resistance, and possibly diabetes mellitus, relates to adverse cardiovascular outcomes.

  11. Ultrasonic Doppler blood flow meter for extracorporeal circulation

    Science.gov (United States)

    Dantas, Ricardo G.; Costa, Eduardo T.; Maia, Joaquim M.; Nantes Button, Vera L. d. S.

    2000-04-01

    In cardiac surgeries it is frequently necessary to carry out interventions in internal heart structures, and where the blood circulation and oxygenation are made by artificial ways, out of the patient's body, in a procedure known as extracorporeal circulation (EC). During this procedure, one of the most important parameters, and that demands constant monitoring, is the blood flow. In this work, an ultrasonic pulsed Doppler blood flowmeter, to be used in an extracorporeal circulation system, was developed. It was used a 2 MHz ultrasonic transducer, measuring flows from 0 to 5 liters/min, coupled externally to the EC arterial line destined to adults perfusion (diameter of 9.53 mm). The experimental results using the developed flowmeter indicated a maximum deviation of 3.5% of full scale, while the blood flow estimator based in the rotation speed of the peristaltic pump presented deviations greater than 20% of full scale. This ultrasonic flowmeter supplies the results in a continuous and trustworthy way, and it does not present the limitations found in those flowmeters based in other transduction methods. Moreover, due to the fact of not being in contact with the blood, it is not disposable and it does not need sterilization, reducing operational costs and facilitating its use.

  12. Pancreatic blood flow in experimental acute pancreatitis

    International Nuclear Information System (INIS)

    The etiology and pathogenesis of acute necrotizing hemorrhagic pancreatitis remain controversial. Recent work has suggested that an early fall in pancreatic blood flow, causing ischemia, may be the initiating factor. Using an established rat model of hemorrhagic pancreatitis and the fractional indicator distribution technique with 86RbCl, pancreatic blood flow and tissue perfusion have been measured at various times in the condition. Six groups of ten rats were studied: control sham operation and pancreatitis groups were sacrificed at 1, 6, and 24 hr. Pancreatic blood flow (% of cardiac output) and perfusion (blood flow/g tissue) were measured. Blood flow was increased by a maximum of 53% at 1 hr (P less than 0.001) and remained elevated for 24 hr, and perfusion was increased by a maximum of 70% (P less than 0.001) at 1 hr and remained elevated at 6 hr. Pancreatic perfusion declines after 6 hr due to increasing gland edema. The results demonstrate a significant increase in pancreatic blood flow and perfusion in experimentally induced acute pancreatitis, suggesting a primary inflammatory response, and refute the ischemic etiological theory

  13. Simple technique for measuring relative renal blood flow

    International Nuclear Information System (INIS)

    To determine whether externally monitored early renal uptake of 131I-hippurate is proportional to renal blood flow, the renal uptake of 131-hippurate at 1 to 2 min after injection was compared with the renal accumulation of radioactive carbonized microspheres in dogs. A renal artery catheter equipped with a balloon was used to decrease renal blood flow unilaterally. One minute after the intravenous injection of 100 μCi of 131I-hippurate, about 1 μCi of either 85Sr- or 95Nb-labeled carbon microspheres was injected into the left ventricle. Radioactivity was measured over both kidneys. The total radioactivity within each kidney region of interest was corrected for background and integrated over the 1 to 2 min interval after injection. Thirteen measurements of relative renal blood flow were made for seven dogs. The dogs were then killed and both kidneys were excised and counted for the radioactivity of the microspheres. The 1 to 2-min relative renal uptake of 131I-hippurate correlated well with relative microsphere uptake, suggesting that relative renal blood flow can be simply determined from the external measurements of renal uptake of 131I-hippurate

  14. Increasing pulmonary artery pulsatile flow improves hypoxic pulmonary hypertension in piglets.

    Science.gov (United States)

    Courboulin, Audrey; Kang, Chantal; Baillard, Olivier; Bonnet, Sebastien; Bonnet, Pierre

    2015-01-01

    Pulmonary arterial hypertension (PAH) is a disease affecting distal pulmonary arteries (PA). These arteries are deformed, leading to right ventricular failure. Current treatments are limited. Physiologically, pulsatile blood flow is detrimental to the vasculature. In response to sustained pulsatile stress, vessels release nitric oxide (NO) to induce vasodilation for self-protection. Based on this observation, this study developed a protocol to assess whether an artificial pulmonary pulsatile blood flow could induce an NO-dependent decrease in pulmonary artery pressure. One group of piglets was exposed to chronic hypoxia for 3 weeks and compared to a control group of piglets. Once a week, the piglets underwent echocardiography to assess PAH severity. At the end of hypoxia exposure, the piglets were subjected to a pulsatile protocol using a pulsatile catheter. After being anesthetized and prepared for surgery, the jugular vein of the piglet was isolated and the catheter was introduced through the right atrium, the right ventricle and the pulmonary artery, under radioscopic control. Pulmonary artery pressure (PAP) was measured before (T0), immediately after (T1) and 30 min after (T2) the pulsatile protocol. It was demonstrated that this pulsatile protocol is a safe and efficient method of inducing a significant reduction in mean PAP via an NO-dependent mechanism. These data open up new avenues for the clinical management of PAH. PMID:25993379

  15. Quantitative measurement of total cerebral blood flow using 2D phase-contrast MRI and doppler ultrasound

    International Nuclear Information System (INIS)

    To compare of quantitative measurement of the total cerebral blood flow using two-dimensional phase-contrast MR imaging and Doppler ultrasound. In 16 volunteers (mean age, 26 years; mean body weight, 66 kg) without abnormal medical histories, two-dimensional phase-contrast MR imaging was performed at the level of the C2-3 inter vertebral disc for flow measurement of the internal carotid arteries and the vertebral arteries. Volume flow measurements using Doppler ultrasound were also performed at the internal carotid arteries 2cm above the carotid bifurcation, and at the vertebral arteries at the level of the upper pole of the thyroid gland. Flows in the four vessels measured by the two methods were compared using Wilcoxon's correlation analysis and the median score. Total cerebral blood flows were calculated by summing these four vessel flows, and mean values for the 16 volunteers were calculated. Cerebral blood flows measured by 2-D phase-contrast MR imaging and Doppler ultrasounds were 233 and 239 ml/min in the right internal carotid artery, 250 and 248 ml/min in the left internal carotid artery, 62 and 56 ml/min in the right vertebral artery, and 83 and 68 ml/min in the left vertebral artery. Correlation coefficients of the blood flows determined by the two methods were 0.48, 0.54, 0.49, and 0.62 in each vessel, while total cerebral blood flows were 628±68 (range, 517 to 779) ml/min and 612±79 (range, 482 to 804)ml/min, respectively. Total cerebral blood flow was easily measured using 2-D phase-contrast MR imaging and Doppler ultrasound, and the two noninvasive methods can therefore be used clinically for the measurement of total cerebral blood flow

  16. GPU-Based Parallelized Solver for Large Scale Vascular Blood Flow Modeling and Simulations.

    Science.gov (United States)

    Santhanam, Anand P; Neylon, John; Eldredge, Jeff; Teran, Joseph; Dutson, Erik; Benharash, Peyman

    2016-01-01

    Cardio-vascular blood flow simulations are essential in understanding the blood flow behavior during normal and disease conditions. To date, such blood flow simulations have only been done at a macro scale level due to computational limitations. In this paper, we present a GPU based large scale solver that enables modeling the flow even in the smallest arteries. A mechanical equivalent of the circuit based flow modeling system is first developed to employ the GPU computing framework. Numerical studies were employed using a set of 10 million connected vascular elements. Run-time flow analysis were performed to simulate vascular blockages, as well as arterial cut-off. Our results showed that we can achieve ~100 FPS using a GTX 680m and ~40 FPS using a Tegra K1 computing platform. PMID:27046603

  17. Regulation of the skeletal muscle blood flow in humans

    DEFF Research Database (Denmark)

    Mortensen, Stefan; Saltin, Bengt

    2014-01-01

    hyperaemia whereas the role of ATP remains uncertain due to lack of specific purinergic receptor blockers for human use. The purpose of this review is to address the interaction between vasodilator systems and to discuss the multiple proposed roles of ATP in human skeletal muscle blood flow regulation......In humans, skeletal muscle blood flow is regulated by an interaction between several locally formed vasodilators including nitric oxide (NO) and prostaglandins. In plasma, ATP is a potent vasodilator that stimulates the formation of NO and prostaglandins and very importantly can offset local...... sympathetic vasoconstriction. ATP is released into plasma from erythrocytes and endothelial cells and the plasma concentration increases in both the feeding artery and the vein draining the contracting skeletal muscle. Adenosine also stimulates the formation of NO and prostaglandins, but the plasma adenosine...

  18. Intracerebral regional distribution of blood flow in response to uterine contractions in growth-restricted human fetuses.

    OpenAIRE

    Fu, Jing; Olofsson, Per

    2007-01-01

    Objective: To explore middle cerebral artery (MCA) and anterior cerebral artery (ACA) blood flow responses to superimposed acute hypoxemia in growth -restricted fetuses with and without established brain-sparing flow during basal conditions. Material and methods: 47 term fetuses suspected of growth restriction were exposed to an oxytocin challenge test with simultaneous cardiotocography and Doppler velocimetry in the umbilical artery, MCA and ACA. The MCA-to-ACA pulsatility index (PI) ratio w...

  19. Acute occlusion of the left subclavian artery with artery dissection

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ Subclavian steal syndrome is cerebral or brain stem ischemia resulting from diversion of blood flow from the basilar artery to the subclavian artery, which is caused by occlusive disease of either the subclavian artery or the innominate artery before they branch off at the vertebral artery. In the patients with subclavian steal syndrome the subclavian artery is fed by retrograde flow from the vertebral artery via the carotids and the circle of Willis.

  20. Transient Non-Newtonian Blood Flow under Magnetic Targeting Drug Delivery in an Aneurysm Blood Vessel with Porous Walls

    Science.gov (United States)

    Alimohamadi, Haleh; Imani, Mohsen

    2014-11-01

    The present investigation deals with numerical solution of blood flow patterns through an aneurysm artery under the applied magnetic field. Transient extended Navier-Stokes, Brinkman, continuity, and heat conduction equations govern this phenomenon and unsteady pulsatile inlet velocity varies by human heart-beating frequency. Our simulation demonstrates applying 105 magnetic field intensity (MnF) to recirculate flow and increase fluid flux and maximum blood temperature by 62.5x and 3.5%, respectively, in the aneurysm region. It is also shown that the vessel's wall porosity plays an important role in magnetic targeting of drug delivery performance, as this parameter can noticeably change maximum blood temperature and pressure.

  1. Dehydration accelerates reductions in cerebral blood flow during prolonged exercise in the heat without compromising brain metabolism

    DEFF Research Database (Denmark)

    Trangmar, Steven J; Chiesa, Scott T; Llodio, Iñaki;

    2015-01-01

    Dehydration hastens the decline in cerebral blood flow (CBF) during incremental exercise, whereas the cerebral metabolic rate for O2 (CMRO2 ) is preserved. It remains unknown whether CMRO2 is also maintained during prolonged exercise in the heat and whether an eventual decline in CBF is coupled to...... fatigue. Two studies were undertaken. In study 1, 10 male cyclists cycled in the heat for ∼2 h with (control) and without fluid replacement (dehydration) while internal and external carotid artery blood flow and core and blood temperature were obtained. Arterial and internal jugular venous blood samples...... were assessed with dehydration to evaluate CMRO2 . In study 2, in 8 male subjects, middle cerebral artery blood velocity was measured during prolonged exercise to exhaustion in both dehydrated and euhydrated states. After a rise at the onset of exercise, internal carotid artery flow declined to...

  2. The effect of halothane on the distribution of cardiac output and organ blood flows in the hemorrhagic, hypotensive dog

    International Nuclear Information System (INIS)

    Halothane was given to dogs which had been bled to an arterial mean blood pressure of 60 mmHg, and the circulatory effects were studied with the aid of the radioactive microsphere technique. The cardiac output and coronary blood flow were well maintained, whereas the arterial mean blood pressure was slightly, and the stroke volume markedly increased, indicating an improved heart function. The blood flows to the brain, lungs, liver and kidneys were well preserved throughout the anesthesia. The effect of retransfusing the withdrawn blood was also studied, and it resulted in an increased cardiac output, arterial mean blood pressure and increased blood flows to the heart, lungs, spleen, bowel and liver. (author)

  3. Variação do fluxo sanguíneo da artéria central da retina durante as diferentes fases do ciclo menstrual ovulatório Central retinal artery blood flow variation during menstrual cycle

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Viana

    2007-03-01

    Full Text Available OBJETIVO: avaliar a resistência vascular da artéria central da retina, por meio do fluxo Doppler, nas diferentes fases do ciclo menstrual ovulatório. MÉTODOS: estudo observacional, longitudinal e prospectivo com avaliação de 34 mulheres saudáveis, submetidas a estudo dopplerfluxométrico do fundo do olho para avaliação da resistência vascular da artéria central da retina nas posições sentada e deitada, durante quatro fases do ciclo menstrual: fase folicular inicial, fase folicular média, fase periovulatória e fase lútea média. A confirmação da ovulação no ciclo de estudo foi feita pela dosagem de progesterona sérica na fase lútea média. Foram avaliados os índices de pulsatilidade (IP e de resistência, e as velocidades máxima, mínima e média. RESULTADOS: a idade média foi de 29,7 anos. Não foram observadas diferenças entre os índices obtidos para ambos os olhos; assim, utilizamos as médias dos índices para realizar o cálculo estatístico. Quando comparadas às posições de realização do exame, detectou-se um IP maior na posição sentada; assim, as análises foram avaliadas em separado, respeitando-se a posição da paciente. O IP da artéria central da retina, avaliado com a paciente deitada, variou durante o ciclo menstrual, apresentando-se significativamente mais baixo nas fases folicular média (1,5±0,3 e periovulatória (1,5±0,3 quando comparadas às fases folicular precoce (1,7±0,4 e lútea média (1,7±0,4. Quando a avaliação foi feita com a paciente sentada não foram observadas diferenças para as diferentes fases do ciclo. CONCLUSÕES: num ciclo menstrual ovulatório ocorre diminuição da resistência vascular na artéria central da retina e posterior reversão do efeito, como demonstrado pelas variações do IP.PURPOSE: to evaluate the vascular blood flow of the central retinal arteries using dopplervelocimetry in the different phases of the ovulatory menstrual cycle. METHODS: we performed

  4. Straight versus tortuous retinal arteries in relation to blood pressure and genetics

    DEFF Research Database (Denmark)

    Taarnhøj, N C B B; Munch, I C; Sander, B;

    2008-01-01

    dizygotic same-sex healthy twin pairs, aged 20 to 46 years, who were characterised by determination of retinal vessel diameters, arterial blood pressure, blood glucose, body mass index, smoking habits and retinal arterial tortuosity, using a three-level grading scale (straight, wavy, tortuous). Heritability...... factors accounting for the remaining 18% (CI(95 )8, 36%). Increasing values of mean arterial blood pressure and body mass index were both associated with decreasing levels of retinal arterial tortuosity. CONCLUSION: There was a large variation in tortuosity of retinal arteries in these healthy subjects...

  5. A dynamic model of renal blood flow autoregulation

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Marsh, D J

    1994-01-01

    of renal autoregulation, a broad band perturbation of the arterial pressure was employed in both the simulations and the experiments. Renal blood flow and tubular pressure were used as response variables in the comparison. To better approximate the situation in vivo where a large number of individual...... observations. However, in combination they reproduced most of hte features of the various transfer functions calculated from the experimental data. The major discrepancy was the presence of a bimodal distribution of the admittance phase in the simulations. This is not consistent with most of the experimental...

  6. Blood flow and oxygenation in peritendinous tissue and calf muscle during dynamic exercise in humans

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Langberg, H; Green, Sara Marie Ehrenreich;

    2000-01-01

    1. Circulation around tendons may act as a shunt for muscle during exercise. The perfusion and oxygenation of Achilles' peritendinous tissue was measured in parallel with that of calf muscle during exercise to determine (1) whether blood flow is restricted in peritendinous tissue during exercise...... output by dye dilution, arterial pressure by an arterial catheter-transducer, and muscle and peritendinous O2 saturation by spatially resolved spectroscopy (SRS). 3. Calf blood flow rose 20-fold with exercise, reaching 44 +/- 7 ml (100 g)-1 min-1 (mean +/- s.e.m. ) at 9 W, while Achilles' peritendinous...... with a rise in leg vascular conductance and microvascular haemoglobin volume, despite elevated systemic vascular resistance. 4. The parallel rise in calf muscle and peritendinous blood flow and fall in O2 saturation during exercise indicate that blood flow is coupled to oxidative metabolism in both...

  7. Renal blood flow distribution during E. coli endotoxin shock in dog.

    Science.gov (United States)

    Kirkebø, A; Tyssebotn, I

    1980-04-01

    The effect of endotoxin on renal blood flow distribution was studied in anesthetized dogs. Renal blood flow was measured as hydrogen clearance by platinum electrodes placed in outer and in inner halves of cortex and by electromagnetic flowmeter. Intravenous injection of E. coli endotoxin, 3-5 mg/kg b. wt., promptly reduced arterial blood pressure (AP) and renal blood flow. After a transient increase for 45 min AP and renal blood flow declined to about 50% of the control 2 1/2-3 h after injection. The reduction in outer cortical blood flow (OCF) was not significantly different from the reduction in inner cortical blood flow (ICF). The hematocrit (Hct) increased from 40.1 +/- 3.8% to 54.6 +/- 8%, but mean renal vascular resistance did not change. Total plasma protein concentration was not significantly elevated. A marked local flow variability was observed in some periods during the phase of shock with declining AP and total renal blood flow at high Hct. Thus renal blood flow showed phasic changes, but the OCF/ICF ratio was not changed during endotoxin shock. Local blood flow instability was observed periodically at high Hct. PMID:6998257

  8. Measurement of limb blood flow using technetium-labelled red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Parkin, A; Robinson, P.J.; Wiggins, P.A.; Leveson, S.H.; Salter, M.C.P.; Matthews, I.F.; Ware, F.M.

    1986-05-01

    A method for measuring blood flow below the knee during reactive hyperaemia induced by 3 min of arterial occlusion has been developed. Subjects are positioned with lower limbs within the field of view of a gamma camera and pneumatic cuffs are placed below the knees to isolate the blood and induce a hyperaemic response. The remaining blood pool is labelled with /sup 99/Tcsup(m)-labelled red cells. Blood flows have been derived from the initial gradients of time-activity curves and from equilibrium blood sampling. The technique has been validated using a tissue-equivalent leg phantom and peristaltic pump. The method has been applied to a small group of patients with peripheral vascular disease and to normal controls. The mean value (+-SD) of limb perfusion for normal controls was found to be 16.4 +- 3.0 ml/100 ml/min and for patients with intermittent claudication was 5.1 +- 2.6 ml/100 ml/min. Flow measurements are found to correlate with clinical findings and with symptoms. Reproducibility (established by repeated measurements) is high. The method is well tolerated even by patients suffering from rest pain.

  9. The measurement of limb blood flow using technetium-labelled red blood cells

    International Nuclear Information System (INIS)

    A method for measuring blood flow below the knee during reactive hyperaemia induced by 3 min of arterial occlusion has been developed. Subjects are positioned with lower limbs within the field of view of a gamma camera and pneumatic cuffs are placed below the knees to isolate the blood and induce a hyperaemic response. The remaining blood pool is labelled with 99Tcsup(m)-labelled red cells. Blood flows have been derived from the initial gradients of time-activity curves and from equilibrium blood sampling. The technique has been validated using a tissue-equivalent leg phantom and peristaltic pump. The method has been applied to a small group of patients with peripheral vascular disease and to normal controls. The mean value (+-SD) of limb perfusion for normal controls was found to be 16.4+-3.0 ml/100 ml/min and for patients with intermittent claudication was 5.1+-2.6 ml/100 ml/min. Flow measurements are found to correlate with clinical findings and with symptoms. Reproducibility (established by repeated measurements) is high. The method is well tolerated even by patients suffering from rest pain. (author)

  10. Development of skin surface radiation detector system to monitor radioactivity in arterial blood with positron emission tomography

    International Nuclear Information System (INIS)

    Positron emission tomography (PET) is a unique method to determine quantitatively and localize precisely human physiological functions. The measurement of regional cerebral blood flow (rCBF) is one of the most commonly used clinical PET studies. Two conventional methods are commonly used to measure the time course of activity concentration (TCC) in arterial blood. A new type detector system for measuring the TCC in the arterial blood of a subject in PET study without taking the arterial blood have been developed. The system measures the radioactivity in arterial blood through the skin of a subject. A detector is placed on the skin over a wrist. The block diagram of the detector system is shown. It was tried to measure 15O activity (half life: 122s). The nuclei emit the positrons of maximum energy 1.73 MeV, which has about 9 mm range in tissues, and can penetrate through a skin from an artery. The phantom experiment to examine the performance of the detector system and the clinical PET study and their results are reported. (K.I.)

  11. Cerebral angiography, blood flow and vascular reactivity in progressive hypertension

    Science.gov (United States)

    Li, Yunxia; Shen, Qiang; Huang, Shiliang; Li, Wei; Muir, Eric R.; Long, Justin; Duong, Timothy Q.

    2015-01-01

    Chronic hypertension alters cerebral vascular morphology, cerebral blood flow (CBF), cerebrovascular reactivity, increasing susceptibility to neurological disorders. This study evaluated: i) the lumen diameters of major cerebral and downstream arteries using magnetic resonance angiography, and ii) basal CBF, and iii) cerebrovascular reactivity to hypercapnia of multiple brain regions using arterial-spin-labeling technique in spontaneously hypertensive rats (SHR) at different stages. Comparisons were made with age-matched normotensive Wistar Kyoto (WKY) rats. In 10-week SHR, lumen diameter started to reduce, basal CBF, and hypercapnic CBF response were higher from elevated arterial blood pressure, but there was no evidence of stenosis, compared to age-matched WKY. In 20-week SHR, lumen diameter remained reduced, CBF returned toward normal from vasoconstriction, hypercapnic CBF response reversed and became smaller, but without apparent stenosis. In 40-week SHR, lumen diameter remained reduced and basal CBF further decreased, resulting in larger differences compared to WKY. There was significant stenosis in main supplying cerebral vessels. Hypercapnic CBF response further decreased, with some animals showing negative hypercapnic CBF responses in some brain regions, indicative of compromised cerebrovascular reserve. The territory with negative hypercapnia CBF responses corresponded with the severity of stenosis in arteries that supplied those territories. We also found enlargement of downstream vessels and formation of collateral vessels as compensatory responses to vasoconstriction upstream vessels. The middle cerebral and azygos arteries were amongst the most susceptible to hypertension-induced changes. Multimodal MRI provides clinically relevant data that might be useful to characterize disease pathogenesis, stage disease progression, and monitor treatment effects in hypertension. PMID:25731987

  12. Pulsatile flow of blood and heat transfer with variable viscosity under magnetic and vibration environment

    Energy Technology Data Exchange (ETDEWEB)

    Shit, G.C., E-mail: gopal_iitkgp@yahoo.co.in; Majee, Sreeparna

    2015-08-15

    Unsteady flow of blood and heat transfer characteristics in the neighborhood of an overlapping constricted artery have been investigated in the presence of magnetic field and whole body vibration. The laminar flow of blood is taken to be incompressible and Newtonian fluid with variable viscosity depending upon temperature with an aim to provide resemblance to the real situation in the physiological system. The unsteady flow mechanism in the constricted artery is subjected to a pulsatile pressure gradient arising from systematic functioning of the heart and from the periodic body acceleration. The numerical computation has been performed using finite difference method by developing Crank–Nicolson scheme. The results show that the volumetric flow rate, skin-friction and the rate of heat transfer at the wall are significantly altered in the downstream of the constricted region. The axial velocity profile, temperature and flow rate increases with increase in temperature dependent viscosity, while the opposite trend is observed in the case of skin-friction and flow impedance. - Highlights: • We have investigated the pulsatile MHD flow of blood and heat transfer in arteries. • The influence of periodic body acceleration has been taken into account. • The temperature dependent viscosity of blood is considered. • The variable viscosity has an increasing effect on blood flow and heat transfer. • The overall temperature distribution enhances in the presence of magnetic field.

  13. Pulsatile flow of blood and heat transfer with variable viscosity under magnetic and vibration environment

    International Nuclear Information System (INIS)

    Unsteady flow of blood and heat transfer characteristics in the neighborhood of an overlapping constricted artery have been investigated in the presence of magnetic field and whole body vibration. The laminar flow of blood is taken to be incompressible and Newtonian fluid with variable viscosity depending upon temperature with an aim to provide resemblance to the real situation in the physiological system. The unsteady flow mechanism in the constricted artery is subjected to a pulsatile pressure gradient arising from systematic functioning of the heart and from the periodic body acceleration. The numerical computation has been performed using finite difference method by developing Crank–Nicolson scheme. The results show that the volumetric flow rate, skin-friction and the rate of heat transfer at the wall are significantly altered in the downstream of the constricted region. The axial velocity profile, temperature and flow rate increases with increase in temperature dependent viscosity, while the opposite trend is observed in the case of skin-friction and flow impedance. - Highlights: • We have investigated the pulsatile MHD flow of blood and heat transfer in arteries. • The influence of periodic body acceleration has been taken into account. • The temperature dependent viscosity of blood is considered. • The variable viscosity has an increasing effect on blood flow and heat transfer. • The overall temperature distribution enhances in the presence of magnetic field

  14. Glucagon-like peptide-2 (GLP-2) increases small intestinal blood flow and mucosal growth in ruminating calves

    DEFF Research Database (Denmark)

    Taylor-Edwards, C C; Burrin, D G; Holst, Jens Juul; McLeod, K R; Harmon, D L

    2011-01-01

    Glucagon-like peptide-2 (GLP-2) increases small intestinal mass and blood flow in nonruminants but its effect in ruminants is unknown. Eight Holstein calves with an ultrasonic flow probe around the superior mesenteric artery and catheters in the carotid artery and mesenteric vein were paired by age......, GLP-2 increased villus height, crypt depth, and BrdU-labeling in small intestinal segments. These results demonstrate that GLP-2 induces similar increases in small intestinal blood flow and growth in ruminants to those observed in nonruminants. Furthermore, GLP-2 increases small intestinal blood flow...

  15. Increased blood flow prevents intramucosal acidosis in sheep endotoxemia: a controlled study

    OpenAIRE

    Dubin, Arnaldo; Murias, Gastón; Maskin, Bernardo; Pozo, Mario O; Sottile, Juan P; Barán, Marcelo; Edul, Vanina S Kanoore; Canales, Héctor S; Badie, Julio C; Etcheverry, Graciela; Estenssoro, Elisa

    2005-01-01

    Introduction Increased intramucosal–arterial carbon dioxide tension (PCO2) difference (ΔPCO2) is common in experimental endotoxemia. However, its meaning remains controversial because it has been ascribed to hypoperfusion of intestinal villi or to cytopathic hypoxia. Our hypothesis was that increased blood flow could prevent the increase in ΔPCO2. Methods In 19 anesthetized and mechanically ventilated sheep, we measured cardiac output, superior mesenteric blood flow, lactate, gases, hemoglobi...

  16. Effects of exercise training with blood flow restriction on blood pressure in medicated hypertensive patients

    Directory of Open Access Journals (Sweden)

    Marcos Antônio Cezar

    2016-06-01

    Full Text Available Abstract The development of non-pharmacological approaches to hypertension (HA is critical for both prevention and treatment. This study examined the hemodynamic and biochemical responses of medicated hypertensive women to resistance exercise with blood flow restriction (vascular occlusion. Twenty-three women were randomly assigned to one of three groups: High intensity strength training (n = 8; low-intensity resistance exercise with occlusion (n = 8; and control (n = 7. The first two groups underwent eight weeks of training performed twice a week, including three series of wrist flexion exercises with or without vascular occlusion. The exercised with occlusion group showed pre- to post-test reduction in systolic and diastolic blood pressure, mean arterial pressure, and double product, whereas the other groups showed no significant hemodynamic changes. In conclusion, resistance exercise during 8 weeks was effective in lowering blood pressure in medicated hypertensive subjects.

  17. Doppler Assessment of Uterine Blood Flow in Recurrent Pregnancy Loss

    Directory of Open Access Journals (Sweden)

    Maryam Barzin

    2011-05-01

    Full Text Available Recurrent spontaneous abortion affects 2%-5% of"ncouples. Uterine perfusion is considered as one of the"nfactors that influences the success of implantation."nDuring the normal menstrual cycle, the impedance"nto uterine artery blood flow diminishes progressively"nduring the luteal phase, reaching the lowest values"nin the period coinciding with the implantation time."nImpedance of uterine arteries is a good indicator of"nthe possibility of a subsequent pregnancy. High blood"nflow resistance is associated with a reduced conception"nrate and women with lower pulsatility index values"nhave the highest possibility of becoming pregnant. An"nimpaired uterine perfusion could play a major role in"nthe pathogenesis of recurrent spontaneous abortion. In"nthis study, we examined sixty women with recurrent"nspontaneous abortion and a control group including"nthirty normal women with at least one previous"nuncomplicated pregnancy and without history of any"nabortion. Transvaginal sonography associated with"nDoppler flow measurement was performed during"nthe midluteal phase of a cycle in all women. The"nmeasurement of the ascending branch of both right"nand left uterine arteries was taken lateral to the cervix"nat the level of the internal os. The pulsatility and"nresistance index of both uterine arteries were calculated"nand compared in both groups. In this presentation we"nreport our finding in two groups. We also explain the"nexact method of study and present some interesting"ncases

  18. Progressive Deconstruction of a Distal Posterior Cerebral Artery Aneurysm Using Competitive Flow Diversion.

    Science.gov (United States)

    Johnson, Andrew K; Tan, Lee A; Lopes, Demetrius K; Moftakhar, Roham

    2016-03-01

    Progressive deconstruction is an endovascular technique for aneurysm treatment that utilizes flow diverting stents to promote progressive thrombosis by diverting blood flow away from the aneurysm's parent vessel. While the aneurysm thromboses, collateral blood vessels develop over time to avoid infarction that can often accompany acute parent vessel occlusion. We report a 37-year-old woman with a left distal posterior cerebral artery aneurysm that was successfully treated with this strategy. The concept and rationale of progressive deconstruction are discussed in detail. PMID:26958413

  19. Relationship of daily arterial blood pressure monitoring readings and arterial stiffness profile in male patients with chronic obstructive pulmonary disease combined with arterial hypertension

    Directory of Open Access Journals (Sweden)

    Karoli N.A.

    2013-06-01

    Full Text Available The aim of the study was to determine correlation between arterial blood pressure daily rhythm and daily profile of arterial stiffness in male patients with chronic obstructive pulmonary disease (COPD and arterial hypertension. Materials et methods: Prospective investigation comprised 45 male patients with COPD and arterial hypertension. Individuals of 40 years younger and 80 years elder, patients with diabetes, stroke, angina pectoris, or heart infarction, vascular diseases, and exacerbation of chronic disease, bronchial and pulmonary diseases of other etiology were excluded from the analyses. Comparison group included 47 patients with essential arterial hypertension and without chronic respiratory diseases closely similar on general parameters with patients from main clinical series. Twenty-four-hour arterial blood pressure monitoring (ABPM and daily arterial stiffness monitoring were performed using BPLab® MnSDP-2 apparatus (Petr Telegin, Russian Federation. Results: Patients with COPD combined with arterial hypertension with raised arterial stiffness measures prevail over individuals in essential hypertension group. There is pathological alteration of the ABPM circadian rhythm and raised «Pressure load» values in raised arterial stiffness group. Conclusion: We found ABPM raised parameters in patients with COPD and arterial hypertension. It confirms necessity of ABPM in daily arterial stiffness assessment in patients with COPD.

  20. In vivo determination of bone blood flow

    International Nuclear Information System (INIS)

    Quantitative measurement of bone blood flow is vital to understand the hemodynamics of bone systems especially in the study of asceptic bone necroses. These ''silent bends'' result from micro-emboli in femoral arterioles from small nitrogen bubbles released from lipids during a diver's ascent. A technique to determine bone blood flow in vivo has been developed by measuring the rate of inert gas washout of Ar-41 (t /sub 1/2/ = 1.83 h, E = 1293 keV) from the bone mineral matrix. Argon gas is formed in vivo by neutron activation of Ca-44 using 14.3 MeV neutrons, following the reaction Ca-44(n, α)Ar-41. The blood flow in the irradiated bone is determined by measuring the clearance rate of Ar-41 using gamma-ray spectroscopy. To date, measurements have been made on dead and living rats (weight 300g). The results indicated that in the no-flow situation the clearance rate is consistent with the physical half-life of Ar-41, while for the live rats the clearance rate for argon is dependent on the flow of blood in the bone. The observed clearance times correspond to flows greater than 3 ml of blood per 100 ml of argon distribution volume/min (F/pV), with the bone-blood partition coefficient for argon approximately one. In addition, measurements of the partitioning of argon and other gases with bone have been measured in order to understand blood-bone systems more fully

  1. Elementary theory of synchronous arterio-arterial blood pumps

    Science.gov (United States)

    Jones, R. T.; Petscheck, H. E.; Kantrowitz, A. R.

    1976-01-01

    In the technique of arterio-arterial pumping, a volume of fluid is withdrawn from the aorta during systole and reinjected during diastole, thereby reducing the systolic pressure of the heart and adding energy to the systemic circulation. It is found that an upper bound for the effectiveness of such devices is given by a formula that considers stroke output of the unaided heart and the increment caused by the pump with a stroke. The division of effort of the pump between the reduction of pressure and the increase of flow depends on the physiological mechanical impedance of the heart. The total effect is, however, independent of the impedance.

  2. Regional cerebral blood flow in schizophrenic patients

    International Nuclear Information System (INIS)

    Seventy-six schizophrenic patients were examined by a Xe-133 inhalation method to determine regional cerebral blood flow. A decreased blood flow was observed in the frontal lobe, especially in the right inferior part. In a study on the relationship between disease subtypes and regional cerebral blood flow, negative symptoms were found more predominantly associated with dissolution type than delusion type. In the group of dissolution type, a decreased blood flow was observed in both the right inferior frontal lobe and the right upper hemisphere, in comparison to the group of delution type. Patients presenting with auditory hallucination had a significantly higher incidence of both negative and positive symptoms, as compared with those not presenting with it. In such patients, a significantly decreased blood flow was also seen in the left upper frontal lobe and the bilateral parietal lobe. Xe-133 inhalation method should assist in evaluating brain function in schizophrenic patients, thus leading to the likelihood of developing a new treatment modality. (N.K.)

  3. Daily rhythms in renal blood flow and urine production rate in the near-term sheep fetus

    NARCIS (Netherlands)

    Poortinga, FMI; Aarnoudse, JG

    2000-01-01

    Daily rhythmicity of renal blood flow (RBF) and urine flow (UF) was studied in fetal sheep between 121-125 d of gestation. Fetal arterial blood pressure, heart rate, UF, and right RBF were measured continuously for 24-h periods in 10 sheep, Rhythmic variations during a 24-h period were found for all

  4. The pulmonary vasculature in a neonatal porcine model with increased pulmonary blood flow and pressure

    DEFF Research Database (Denmark)

    Stenbøg, Elisabeth Vidstid; Steinbruchel, Daniel Andreas; Thomsen, Anne Bloch;

    2001-01-01

    models which reflect the disease process. Material and Results: We randomly allocated 45 newborn pigs, at the age of 48 hrs, to groups in which there was either construction of a 3 mm central aorto-pulmonary shunt, undertaken in 9, or ligation of the left pulmonary artery, achieved in 13. Controls...... included sham operations in 13, or no operations in 10 pigs. Follow-up was continued for three months. The interventions were compatible with survival in most pigs. The shunts resulted in an acute 85% increase in systolic pulmonary arterial pressure, and a more than twofold increase in pulmonary blood flow....... By three months of age, nearly all shunts had closed spontaneously, and haemodynamics were normal. Ligation of the left pulmonary artery resulted in a normal total pulmonary blood flow, despite only the right lung being perfused, and a 33% increase in systolic pulmonary arterial pressure. These...

  5. Effects of neuropeptide Y on regulation of blood flow rate in canine myocardium

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Sheikh, S P; Jørgensen, J; Mikkelsen, J D; Paaske, W P; Sejrsen, P; Haunsø, S

    The effect of neuropeptide Y (NPY) on tension development was examined in isolated canine coronary arteries, and the effects on local myocardial blood flow rate were studied in open-chest anesthetized dogs by the local 133Xe washout technique. By immunohistochemistry, numerous NPY-like immunoreac......The effect of neuropeptide Y (NPY) on tension development was examined in isolated canine coronary arteries, and the effects on local myocardial blood flow rate were studied in open-chest anesthetized dogs by the local 133Xe washout technique. By immunohistochemistry, numerous NPY......-like immunoreactive nerve fibers were identified in the adventitia of canine coronary arteries. NPY (10(-9)-10(-6) M) supplied to isolated epicardial segments of the left anterior descending coronary artery induced a modest vasoconstriction, with a maximum tension of 0.95 mN, that was only 6.9% of the response to K...

  6. Regional blood flow distribution in dog during induced hypotension and low cardiac output. Spontaneous breathing versus artificial ventilation.

    OpenAIRE

    Viires, N; Sillye, G; Aubier, M.; Rassidakis, A; Roussos, C

    1983-01-01

    Respiratory muscle blood flow and organ blood flow was studied in two groups of dogs with radioactively labeled microspheres to assess the influence of the working respiratory muscles on the regional distribution of blood flow when arterial pressure and cardiac output were lowered by pericardial tamponade. In one group (n = 6), the dogs were paralyzed and mechanically ventilated (Mv), while in the other (n = 6), they were left to breathe spontaneously (Sb). Cardiac output fell to 30% of contr...

  7. A pitfall in the measurement of arterial blood pressure in the ischaemic limb during elevation

    DEFF Research Database (Denmark)

    Bülow, J; Jelnes, Rolf

    1987-01-01

    In order to evaluate if elevation of the ischaemic limb above heart level is an alternative to the conventionally applied method with external counterpressure for estimation of skin perfusion pressure, femoral and popliteal artery pressures were measured directly in eight patients with occlusion of...... the superficial femoral artery. The measurements were done in the horizontal position and during elevation of the calf above heart level. During elevation relative blood flow, measured by arterio-venous oxygen saturation differences, decreased compared with the horizontal position. In contrast the...... lower extremity cannot be determined non-invasively by elevation of the extremity, probably due to collapse of segments of the vascular bed increasing the vascular resistance considerably....

  8. Sympathetic reflex control of subcutaneous blood flow in tetraplegic man during postural changes

    DEFF Research Database (Denmark)

    Skagen, K; Jensen, K; Henriksen, O;

    1982-01-01

    1. The effect of head-up tilt upon subcutaneous blood flow in the distal arm and leg was studied in 12 patients with complete traumatic spinal cord transection at the cervical level. 2. Blood flow was measured by the local 133Xe washout technique. 3. Leg lowering induced a 47% decrease in blood f...... blockade. Thus the vasoconstriction could be due to a spinal sympathetic reflex mechanism. This as well as local mechanismsincluding the venoarteriolar reflex may play a role in recovery of arterial blood pressure during head-up tilt in the tetraplegic patient....

  9. Impaired flow-induced arterial remodeling in DOCA-salt hypertensive rats

    DEFF Research Database (Denmark)

    Lemkens, Pieter; Nelissen, Jelly; Meens, Merlijn J P M T;

    2012-01-01

    )-salt hypertension in rats, a model for an upregulated endothelin-1 system. Mesenteric small arteries (MrA) were exposed to low blood flow (LF) or high blood flow (HF) for 4 or 7 weeks. The bioavailability of vasoactive peptides was modified by chronic treatment of the rats with the dual neutral endopeptidase (NEP......)/endothelin-converting enzyme (ECE) inhibitor SOL1. After 3 or 6 weeks of hypertension, the MrA showed hypertrophic arterial remodeling (3 weeks: media cross-sectional area (mCSA): 10±1 × 10(3) to 17±2 × 10(3) μm(2); 6 weeks: 13±2 × 10(3) to 24±3 × 10(3) μm(2)). After 3, but not 6, weeks of hypertension, the arterial diameter...... was increased (Ø: 385±13 to 463±14 μm). SOL1 reduced hypertrophy after 3 weeks of hypertension (mCSA: 6 × 10(3)±1 × 10(3) μm(2)). The diameter of the HF arteries of normotensive rats increased (Ø: 463±22 μm) but no expansion occurred in the HF arteries of hypertensive rats (Ø: 471±16 μm). MrA from SOL...

  10. Regulation of blood flow by prostaglandins

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Langberg, H; Risum, N; Kjaer, M

    2004-01-01

    Prostaglandins (PGs) belong to the family of prostanoids together with thromboxanes and are produced mainly from arachadonic acid by the enzyme cyclooxygenase. PGs are known to stimulate platelet aggregation, mediate inflammation and edema, play a role in bone metabolism and in biological...... adaptation of connective tissues e.g. tendon. This review covers the role of PG for mediating tissue blood flow at rest and during increases in metabolic demand such as exercise and reactive hyperaemia. There is strong evidence that PGs contribute to elevate blood flow at rest and during reactive hyperaemia...... in a variety of tissues. Their role for regulating the large increases in muscle blood flow during exercise is less clear which may be explained by redundant mechanisms. Several interactions are known to exist between specific vasodilator substances, and therefore PGs can act in synergy with other...

  11. Complex blood flow quantification using real-time in vivo vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Per, Haugaard;

    for the vector angle estimates was calculated for each box in every frame. For comparison three ultrasound experts evaluated the presence of complex flow in every box. The trial was blinded. For every sequence the mean standard deviation of the vector angle estimates were calculated for box1 {39......A new method to define and quantify complex blood flow is presented. The standard deviations of real-time in vivo vector flow angle estimates are used. Using vector flow ultrasound imaging both carotid bifurcations of two healthy volunteers were scanned. Scanning was performed with a 7.6 MHz linear...... transducer (8670, B-K Medical, Denmark) and a commercial vector flow ultrasound scanner (ProFocus 2202, B-K Medical). Eight video sequences of one cardiac cycle were obtained. In every frame boxes were placed to define the common carotid artery(box1) and the carotid bulb(box2). The standard deviation...

  12. Synchronized renal blood flow dynamics mapped with wavelet analysis of laser speckle flowmetry data

    DEFF Research Database (Denmark)

    Brazhe, Alexey R; Marsh, Donald J; von Holstein-Rathlou, Niels-Henrik;

    2014-01-01

    Full-field laser speckle microscopy provides real-time imaging of superficial blood flow rate. Here we apply continuous wavelet transform to time series of speckle-estimated blood flow from each pixel of the images to map synchronous patterns in instantaneous frequency and phase on the surface...... of rat kidneys. The regulatory mechanism in the renal microcirculation generates oscillations in arterial blood flow at several characteristic frequencies. Our approach to laser speckle image processing allows detection of frequency and phase entrainments, visualization of their patterns, and estimation...

  13. Relationship between leptin levels in maternal blood,amniotic fluid,arterial and venous cord blood and fetal growth

    Institute of Scientific and Technical Information of China (English)

    林丽莎; 薛昭卿; 宋岩峰; 何晓宇

    2003-01-01

    Objective:To study the relationship between leptin concentration and fetal growth.Methods: Levels of leptin in maternal serum, amniotic fluid, arterial and venouscord blood of 65 normal parturients (gestational age 37-42weeks) were measured by ra-dioimmunoassay (RIA) method. At the same time, maternal blood lipids were detected.Neonates were divided into three groups: small for gestational age (SGA) group (n=10), appropriate for gestational age (AGA) group (n=45), large for gestational age(LGA) group (n= 10). Statistical analysis was performed by t test, variance analysisand correlation analysis.Results: (1) There was no obvious correlation between leptin concentrations in ma-ternal serum and arterial/ venous cord blood, amniotic fluid, and also no correlationwith birth weight and placental weight (P>0.05). Maternal body mass index signifi-cantly correlated with birth weight and neonatal length and leptin levels in arterial andvenous cord blood (P<0.01). Leptin levels in arterial and venous cord blood positivelycorrelated significantly with placental and neonatal weight and body length (P<0.01)and negatively correlated with high density lipoprotein (P<0. 01). There was no obvi-ous correlation between fetal gender and leptin concentrations in maternal serum, arteri-al and venous cord blood and amniotic fluid; (2) Leptin levels in arterial and venouscord blood , placental weight in LGA group were significantly higher than those in SGAand AGA group (P<0.05). Among three groups, leptin concentrations in maternalblood were significantly higher than those in arterial and venous cord blood (P<0.05).Conclusions: (1)Fetal leptin is synthesized in uterus, born of itself and placenta.Leptin levels in arterial and venous cord blood are related to the intrauterine growthpattern. It might positively regulate birth weight and body fat content. (2)Either mater-nal or fetal leptin was not correlated with fetal gender. There is no gender difference infetal leptin

  14. The Effect of Doppler Phenomenon on the Speed of Blood Flow

    Directory of Open Access Journals (Sweden)

    Ghaidaa Abdulrahman Khalid

    2012-01-01

    Full Text Available This research studying the phenomenon of Doppler (frequency Doppler as a method through which the direction and speed of the blood cells flows in blood vessels wear measured. This Doppler frequency is relied upon in medicine for measuring the speed of blood flow, because the blood flow is an important concept from the concepts of medicine. It represents the function and efficient of the heart and blood vessels in the body so any defect in this function will appear as a change in the speed of blood flow from the normal value assumed. As this speed changes alot in cases of disease and morbidity of the heart, so in order to identify the effect of changing the Doppler frequency on the speed of blood flow and the relationship of this frequency with the angles of transitions and receptions and the effect of changing the ultrasound transmitted frequencies on the measured velocities .The Doppler ultrasound system has been used which is more efficient and easier to be widely used as a practical application in Al Yarmouk Teaching Hospital on two subjects. The normal had a natural medical history in the blood vessels, and abnormal had carotid artery stenosis. This device will give the flow velocity of blood in the blood vessels which is useful to the examiner, the equation of Doppler as a mathematical model in the research is adopted the measured speed to clarify the amount of change in the frequency (shift in frequency. This speed was measured in five different blood vessels, large arteries (abdominal aorta and carotid artery in the neck and large veins (the inferior vena cava across the abdomen and the external Jugular vein in the neck and capillaries in the hand and fingers. Then using the measured velocities in these vessels the Doppler frequency was calculated from this mathematical model using MATLAB program, was found that as velocity of the blood increases, so does the Doppler frequency and vice versa. The greater the value of the Doppler angle

  15. A new noninvasive device for continuous arterial blood pressure monitoring in the superficial temporal artery

    International Nuclear Information System (INIS)

    Continuous recording of arterial blood pressure (ABP) has many applications in cardiovascular physiology, but existing alternatives rely on measurements performed in the fingers or radial artery. Peripheral recordings have significant differences from central ABP regarding the pattern of the waveform and corresponding systolic and diastolic values. To address the need for noninvasive measurements closer to the ascending aorta, a new device was constructed to measure ABP in the superficial temporal artery (STA) using photoplethysmography and the arterial volume clamping technique. The optoelectronic circuitry to generate the photoplethysmogram is contained in a specially designed probe placed over the STA and kept in place with a head frame. The prototype (STAbp) also includes original designs for the pneumatic, electronic, signal processing, control and display sub-systems. A self-calibration feature regularly updates the photoplethysmogram operating point to improve accuracy. The performance of the STAbp was compared against the Finapres in 19 healthy subjects. At rest, the bias (SDd) was −23.1 (15.05), −10.8 (13.83) and −12.4 (12.93) mmHg for systolic, mean and diastolic pressures respectively, without significant differences in drift between the two devices. The 99% bandwidth (SD) for the spectral distribution of ABP waveforms was 5.3 (1.46) Hz for STAbp and 6.8 (0.73) Hz for the Finapres (p < 0.01). Handgrip manoeuvre showed a very similar response to the Finapres, including the rapid return to baseline on release. The new STAbp device has considerable potential as a new tool for clinical and research applications where continuous recording of more central ABP is advantageous compared to peripheral alternatives. (paper)

  16. Changes of fundus blood flow state of patients with open-angle glaucoma before and after the treatment

    Institute of Scientific and Technical Information of China (English)

    Huai-Jie Huang; Mei-Min Niu; Yi Yang; Ke-Qin Li

    2016-01-01

    Objective:To To study and observe the change situation of fundus blood flow state of patients with open-angle glaucoma before and after the treatment.Methods:A total of 60 patients with open-angle glaucoma treated in our hospital from October 2013 to May 2015 were selected as the observation group, and 60 healthy persons with physical examination at the same period were the control group, then the RI, PI, PSV, EDV and VM levels of ocular artery, central retinal artery and posterior ciliary artery of observation group before the treatment and at 2th, 4th, 8th and 12th week after the treatment and control group were compared.Results:The RI and PI levels of ocular artery, central retinal artery and posterior ciliary artery of observation group before the treatment and at 2th, 4th and 8th week after the treatment were higher than those of control group, while the PSV, EDV and VM levels of ocular artery, central retinal artery and posterior ciliary artery were lower than those of control group. The detection results of observation group at different time after the treatment were better than those before the treatment, and there were significant differences (P0.05).Conclusions:The changes of fundus blood flow state of patients with open-angle glaucoma before and after the treatment are great, and the various artery blood flow presents continuous improvement.

  17. Electromechanical Model of Blood Flow in Vessels

    OpenAIRE

    Ivo Cap; Barbora Czippelova

    2008-01-01

    The present paper deals with some theoretical derivations connected with very efficient method of solution of hydrodynamic problems of blood flow in human cardiovascular system. The electromechanical analogy of liquid flow in a tube and electromagnetic wave propagating along an electric transmission line is discussed. We have derived a detailed circuit-like model of an elementary section of the elastic tube with viscose Newtonian liquid. The analogy harmonic current electrical cir...

  18. Electromechanical Model of Blood Flow in Vessels

    Directory of Open Access Journals (Sweden)

    Ivo Cap

    2008-01-01

    Full Text Available The present paper deals with some theoretical derivations connected with very efficient method of solution of hydrodynamic problems of blood flow in human cardiovascular system. The electromechanical analogy of liquid flow in a tube and electromagnetic wave propagating along an electric transmission line is discussed. We have derived a detailed circuit-like model of an elementary section of the elastic tube with viscose Newtonian liquid. The analogy harmonic current electrical circuit has been designed

  19. Peripheral Artery Disease

    Science.gov (United States)

    ... or atherectomy may be used to help improve blood flow. What is peripheral artery disease (PAD)? How is peripheral artery disease evaluated? How ... PAD are diabetes, smoking, high cholesterol and high blood pressure. Most cases occur in ... is peripheral artery disease evaluated? Several imaging tests can be used to ...

  20. Cerebral blood flow is reduced in patients with sepsis syndrome

    International Nuclear Information System (INIS)

    The relationship between sepsis-induced CNS dysfunction and changes in brain blood flow remains unknown, and animal studies examining the influence of sepsis on cerebral blood flow (CBF) do not satisfactorily address that relationship. We measured CBF and cerebrovascular reactivity to CO2 in nine patients with sepsis syndrome using the 133Xe clearance technique. Mean CBF was 29.6 +/- 15.8 (SD) ml/100 g.min, significantly lower than the normal age-matched value in this laboratory of 44.9 +/- 6.2 ml/100 g.min (p less than .02). This depression did not correlate with changes in mean arterial pressure. Despite the reduction in CBF, the specific reactivity of the cerebral vasculature to changes in CO2 was normal, 1.3 +/- 0.9 ml/100 g.min/mm Hg. Brain blood flow is reduced in septic humans; the contribution of this reduction to the metabolic and functional changes observed in sepsis requires further study

  1. EFFECTS OF VASCULAR ZERO-STRESS STATE ON PULSATILE BLOOD FLOW

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In this paper, blood flow in artery was treated as the flow under equilibrium state (the steady flow under mean pressure) combined with the periodically small pulsatile flow. Based on vascular zero-stress state[1], the pulsatile strains according to the radial and axial displacements of blood vessel were obtained. With the use of Hooke’s law, the pulsatile strains and the corresponding Cauchy stresses were connected, so the corresponding wall motion equations could be established here. By solving the linearized Navier-Stokes equations, the analytic expressions of the blood flow velocities and the vascular displacements could be obtained, and the influence of the circumferential and axial stretch ratio on pulsatile blood flow and vascular motion was discussed in details.

  2. Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement

    OpenAIRE

    Komine Hidehiko; Asai Yoshiyuki; Yokoi Takashi; Yoshizawa Mutsuko

    2012-01-01

    Abstract Background Arterial stiffness is a major contributor to cardiovascular diseases. Because current methods of measuring arterial stiffness are technically demanding, the purpose of this study was to develop a simple method of evaluating arterial stiffness using oscillometric blood pressure measurement. Methods Blood pressure was conventionally measured in the left upper arm of 173 individuals using an inflatable cuff. Using the time series of occlusive cuff pressure and the amplitudes ...

  3. NEW METHOD FOR IMPROVED CALCULATIONS OF UNSTEADY COMPLEX FLOWS IN LARGE ARTERIES

    Institute of Scientific and Technical Information of China (English)

    A. Cheer; Harry A. Dwyer; T. Kim

    2011-01-01

    Using an improved computational fluid dynamics (CFD) method developed for highly unsteady three-dimensional flows,numerical simulations for oscillating flow cycles and detailed unsteady simulations of the flow and forces on the aortic vessels at the iliac bifurcation,for both healthy and diseased patients,are analyzed.Improvements in computational efficiency and acceleration in convergence are achieved by calculating both an unsteady pressure gradient which is due to fluid acceleration and a good global pressure field correction based on mass flow for the pressure Poisson equation.Applications of the enhanced method to oscillatory flow in curved pipes yield an order of magnitude increase in speed and efficiency,thus allowing the study of more complex flow problems such as flow through the mammalian abdominal aorta at the iliac arteries bifurcation.To analyze the large forces which can exist on stent graft of patients with abdominal aortic aneurysm (AAA) disease,a complete derivation of the force equations is presented.The accelerated numerical algorithm and the force equations derived are used to calculate flow and forces for two individuals whose geometry is obtained from CT data and whose respective blood pressure measurements are obtained experimentally.Although the use of endovascular stent grafts in diseased patients can alter vessel geometries,the physical characteristics of stents are still very different when compared to native blood vessels of healthy subjects.The geometry for the AAA stent graph patient studied in this investigation induced flows that resulted in large forces that are primarily caused by the blood pressure.These forces are also directly related to the flow cross-sectional area and the angle of the iliac arteries relative to the main descending aorta.Furthermore,the fluid flow is significantly disturbed in the diseased patient with large flow recirculation and stagnant regions which are not present for healthy subjects.

  4. Non-arterial assessment of blood gas status in patients with chronic pulmonary disease.

    OpenAIRE

    Elborn, J. S.; Finch, M B; Stanford, C. F.

    1991-01-01

    Assessment of blood gas status is important in the management of patients with chronic pulmonary disease. Arterial puncture is often painful and may damage the arterial wall. Measurement of oxygen saturation by transcutaneous oximetry offers a non-invasive alternative to arterial methods but does not allow assessment of partial pressure of carbon dioxide. We have examined the value of oximetry and dorsal hand venous carbon dioxide as an alternative to arterial puncture. Transcutaneous oxygen ...

  5. The blood flow changes associated with idiopathic and secondary intracranial hypertension

    International Nuclear Information System (INIS)

    Full text: The radiological diagnosis of idiopathic intracranial hypertension (IIH) is one of exclusion and as the MR venogram is prone to flow artefacts, the diagnosis of secondary intracranial hypertension (SIH) can also be problematic. The purpose of this paper is to define the blood flow characteristics, which are useful in the diagnosis of these conditions. Twelve patients with clinical findings suggestive of IIH and 12 control subjects were investigated with MR venography and MR flow quantification studies of the cerebral arteries and veins. Total cerebral blood flow, superior sagittal sinus (SSS) and straight sinus (ST) blood flows were measured. MR venography confirmed 7 of the 12 patients had venous outflow obstruction and thus SIH. The remaining 5 patients had IIH. The control patients mean total blood flow was 855 ml/min, the SSS flow was 400ml/min and the ST flow 117 ml/min. The total blood flow in the IIH patients was 46% higher (P = 0.0002) and the ST blood flow 38% higher (P = 0.05) than the control group, the SSS flow was 17% higher but this failed to reach significance. In SIH the SSS flow was reduced by 25% (P = 0.003) compared with the control group, the total and ST blood flow were not significantly altered. In IIH there is hyperaemia and the SSS appears limited in its ability to increase flow, therefore venous collaterals carry a greater load. In SIH, selective obstruction of the SSS reduces flow in this vessel but total blood flow is normal indicating there is also increased flow in collateral veins. Presumably the limited ability of the SSS to drain blood away from the brain in each condition raises venous sinus pressure and alters CSF resorption giving raised CSF pressure. Copyright (2002) Blackwell Science Pty Ltd

  6. Simulation of cardiac motion on non-Newtonian, pulsating flow development in the human left anterior descending coronary artery

    Science.gov (United States)

    Theodorakakos, A.; Gavaises, M.; Andriotis, A.; Zifan, A.; Liatsis, P.; Pantos, I.; Efstathopoulos, E. P.; Katritsis, D.

    2008-09-01

    This study aimed at investigating the effect of myocardial motion on pulsating blood flow distribution of the left anterior descending coronary artery in the presence of atheromatous stenosis. The moving 3D arterial tree geometry has been obtained from conventional x-ray angiograms obtained during the heart cycle and includes a number of major branches. The geometry reconstruction model has been validated against projection data from a virtual phantom arterial tree as well as with CT-based reconstruction data for the same patient investigated. Reconstructions have been obtained for a number of temporal points while linear interpolation has been used for all intermediate instances. Blood has been considered as a non-Newtonian fluid. Results have been obtained using the same pulse for the inlet blood flow rate but with fixed arterial tree geometry as well as under steady-state conditions corresponding to the mean flow rate. Predictions indicate that myocardial motion has only a minor effect on flow distribution within the arterial tree relative to the effect of the blood pressure pulse.

  7. Simulation of cardiac motion on non-Newtonian, pulsating flow development in the human left anterior descending coronary artery

    International Nuclear Information System (INIS)

    This study aimed at investigating the effect of myocardial motion on pulsating blood flow distribution of the left anterior descending coronary artery in the presence of atheromatous stenosis. The moving 3D arterial tree geometry has been obtained from conventional x-ray angiograms obtained during the heart cycle and includes a number of major branches. The geometry reconstruction model has been validated against projection data from a virtual phantom arterial tree as well as with CT-based reconstruction data for the same patient investigated. Reconstructions have been obtained for a number of temporal points while linear interpolation has been used for all intermediate instances. Blood has been considered as a non-Newtonian fluid. Results have been obtained using the same pulse for the inlet blood flow rate but with fixed arterial tree geometry as well as under steady-state conditions corresponding to the mean flow rate. Predictions indicate that myocardial motion has only a minor effect on flow distribution within the arterial tree relative to the effect of the blood pressure pulse

  8. Quantifying Blood Flow in the DIEP Flap: An Ultrasonographic Study

    Science.gov (United States)

    Pennington, David G.

    2014-01-01

    Background: The maximum weight of tissue that a single perforator can perfuse remains an important question in reconstructive microsurgery. An empirically based equation, known as the flap viability index (FVI), has been established to determine what weight of tissue will survive on one or more perforators. The equation is FVI = Sum d(n)^4/W, where d is the internal diameter of each perforator and W is the final weight of the flap. It has been shown that if FVI exceeds 10, total flap survival is likely, but if under 10, partial flap necrosis is probable. The aim of this study was to measure absolute flow rates in deep inferior epigastric perforator (DIEP) flap pedicles and assess correlation with the determinants of the FVI, perforator diameter and flap weight. Methods: Color Doppler ultrasound was used to quantify arterial flow in 10 consecutive DIEP flap pedicles 24 hours after anastomosis. Results: In single-perforator DIEP flaps, flow rate was highly correlated with perforator diameter (r = 0.82, P = 0.01). Mean arterial flow rate was significantly reduced in DIEP flaps with 2 or more perforators (6 vs 38 cm3/min; P perforator size is a critical factor in optimizing blood flow in perforator-based free tissue transfer. Further research is required to understand the flow dynamics of perforator flaps based on multiple perforators. However, surgeons should be cognizant that a single large perforator may have substantially higher flow rates than multiple small perforators. Routine FVI calculation is recommended to ensure complete flap survival. PMID:25426345

  9. Regional cerebral blood flow in aphasia

    DEFF Research Database (Denmark)

    Soh, K; Larsen, B; Skinhøj, E;

    1978-01-01

    Regional cerebral blood flow (rCBF) was studied in 13 aphasic patients with left hemisphere lesions, using the intracarotid xenon 133 injection method and a 254-detector gamma camera system. The rCBF was measured during rest and during various function tests, including a simple speech test. In...

  10. Cerebral blood flow in acute mountain sickness

    DEFF Research Database (Denmark)

    Jensen, J B; Wright, Anne; Lassen, N A;

    1990-01-01

    Changes in cerebral blood flow (CBF) were measured using the radioactive xenon technique and were related to the development of acute mountain sickness (AMS). In 12 subjects, ascending from 150 to 3,475 m, CBF was 24% increased at 24 h [45.1 to 55.9 initial slope index (ISI) units] and 4% increased...

  11. Frequency encoding in renal blood flow regulation

    DEFF Research Database (Denmark)

    Marsh, D.J.; Sosnovtseva, Olga; Pavlov, A.N.;

    2005-01-01

    With a model of renal blood flow regulation, we examined consequences of tubuloglomerular feedback (TGF) coupling to the myogenic mechanism via voltage-gated Ca channels. The model reproduces the characteristic oscillations of the two mechanisms and predicts frequency and amplitude modulation of ...

  12. Xenon computed tomographic blood flow mapping

    International Nuclear Information System (INIS)

    Xenon CT flow information appears to be clinically useful in the diagnosis and management of a broad spectrum of clinical disorders. It also appears to be a useful tool for the experimental study of the cerebral circulation, with recent work also extending to application to the study of solid abdominal organs. The authors therefore found xenon CT CBF mapping to be a useful new blood flow methodology and are of the opinion that as CT technology improves, one will be able to obtain still better flow information with less accompanying radiation exposure and/or a reduction in the level of xenon inhalation required

  13. The effect of varicocele on the right testicular blood flow in patients with left varicocele

    Directory of Open Access Journals (Sweden)

    Oktay Üçer

    2014-03-01

    Full Text Available Objective: There are many theories about the mechanism how varicocele causes infertility. One of these theories is about the negative effect of varicocele on testicular blood flow. We aimed to compare the measurements of testicular blood flow in right and left testes in patients with left varicocele and normal right testes. Methods: Forty-one patients with left varicocele were enrolled in the study. All participants were performed color Doppler sonography to assess testicular blood flow of the both testes. Blood flow parameters such as peak systolic velocity (PSV, end diastolic velocity (EDV, resistive index (RI, pulsatility index (PI were measured in testicular, capsular and intratesticular arteries. Semen parameters were also assessed in the participants. Testicular blood flow parameters were compared between the two testes. Results: Mean age of the patients was 25,95±5,27(16-37. The mean semen parameters of the patients; sperm count (million/ml was 31.56±19.05, motility (% was 51.21±22.27, normal morphology (% was 12.75±2.97 and total motile sperm count (million/ml was 54.92±47.46. There were no statistically significant differences between the testicular blood flow parameters of both testes which are PSV, EDV, RI and PI values in the testicular artery and its branches (capsular and intratesticular arteries(p>0.05. Conclusion: The fact that there were no differences between the blood flows in both testes may depend on the study group who had normal sperm parameters. We suggest that testicular blood flow may be evaluated in patients with left varicocele and impaired sperm parameters.

  14. Changes in mean cerebral blood flow velocity during cognitive task-induced cerebral fatigue in high performance fighter pilots

    Institute of Scientific and Technical Information of China (English)

    Yongsheng Chen

    2008-01-01

    BACKGROUND: Several studies have demonstrated that sustained cognitive tasks can induce cognitive fatigue and that the mean cerebral blood flow velocity changes in some cerebral regions during cerebral fatigue. OBJECTIVE: To dynamically monitor the changes in mean cerebral blood flow velocity in different brain regions of high performance fighter pilots during mental arithmetic tasks and consecutive performance tasks. DESIGN, TIME AND SETTING: The present neurophysiological trial, based on controlled observation, was performed at the Laboratory of Neurophysiology, Institute of Aviation Medicine, Air Force of China between January 2003 and December 2005. PARTICIPANTS: Forty-five males, high performance fighter pilots, averaging (27.6 ± 2.5) years, were recruited for this study. METHODS: The mean cerebral blood flow velocity in the anterior cerebral artery, middle cerebral artery, and posterior cerebral artery of subjects was dynamically tested using transcranial Doppler during 5- hour mental arithmetic tasks and during 5- hour consecutive performance tasks. The neurobehavioral ability index was analyzed throughout each trial according to the number of correct responses, false responses, and lost responses. Simultaneously, cerebral cognitive fatigue-induced lethargy was assessed by the Stanford Sleepiness Scale. MAIN OUTCOME MEASURES: Changes in mean cerebral blood flow velocity in the anterior cerebral artery, middle cerebral artery, and posterior cerebral artery; neurobehavioral ability index of mental arithmetic and consecutive performance tasks; Stanford Sleepiness Scale scores. RESULTS: During mental arithmetic tasks, the mean cerebral blood flow velocity in the anterior cerebral artery increased during hour 2 and decreased after hour 4. There was no significant change in mean cerebral blood flow velocity in the middle cerebral artery and posterior cerebral artery. During hour 4, cerebral cognitive fatigue was observed and, simultaneously, Stanford Sleepiness

  15. Local aggregation characteristics of microscale blood flows

    Science.gov (United States)

    Kaliviotis, Efstathios; Sherwood, Joseph M.; Dusting, Jonathan; Balabani, Stavroula

    2015-11-01

    Erythrocyte aggregation (EA) is an important aspect of microvascular flows affecting blood flow and viscosity. Microscale blood flows have been studied extensively in recent years using computational and microfluidic based approaches. However, the relationship between the local structural characteristics of blood and the velocity field has not been quantified. We report simultaneous measurements of the local velocity, aggregation and haematocrit distributions of human erythrocytes flowing in a microchannel. EA was induced using Dextran and flows were imaged using brightfield microscopy. Local aggregation characteristics were investigated using statistical and edge-detection image processing techniques while velocity profiles were obtained using PIV algorithms. Aggregation intensity was found to strongly correlate with local variations in velocity in both the central and wall regions of the channel. The edge detection method showed that near the side wall large aggregates are associated with high local velocities and low local shear rates. In the central region large aggregates occurred in regions of low velocity and high erythrocyte concentration. The results demonstrate the combined effect of haematocrit and velocity distributions on local aggregation characteristics.

  16. Effect of lying behavior on uterine blood flow in cows during the third trimester of gestation.

    Science.gov (United States)

    Nishida, T; Hosoda, K; Matsuyama, H; Ishida, M

    2004-08-01

    Seven Holstein cows (BW = 639.4 +/- 28.8 kg, age = 62.6 +/- 6.9 mo, parity = 3.1 +/- 0.4 yr) (mean +/- SE) were used to measure uterine blood flow using a transit time ultrasonic flow meter. Ultrasonic flow probes were implanted (d 218 +/- 4 of gestation) around both uterine arteries (n = 3) or the gravid uterine artery (n = 4) to measure variations in uterine blood flow through this vessel in response to postural change (standing and lying). Implantation of the ultrasonic blood flow probe was successful in all 7 cows. Uterine blood flow was measured for 22.9, 23.1, and 21.4 h/d on d 226, 248, and 269 of gestation, respectively. Cows exhibited normal durations of gestation (272.8 +/- 1.6 d), gave birth to normal healthy calves (birth weight = 41.5 +/- 3.0 kg), and did not retain their placenta. Uterine blood flow to the gravid horn during lying was greater than during standing on d 226 (standing vs. lying, 8.04 vs. 8.79 L/min, respectively), d 248 (9.87 vs. 11.06 L/min), and d 269 (8.15 vs. 9.74 L/min) of gestation. Cows spent nearly 50% of their time lying during our observations at all gestational ages. Greater blood supply to the gravid uterus was observed during lying than during standing in this study. PMID:15328259

  17. Coanda effect on ductal flow in the pulmonary artery.

    Science.gov (United States)

    Guntheroth, W; Miyaki-Hull, C

    1999-03-01

    The Coanda effect (the tendency of a jet stream to adhere to a boundary wall), and the relevant anatomy, may explain the location of ductal jets within the main pulmonary artery. With the usual insertion of the duct close to the left pulmonary artery, during right ventricular ejection, the ductal jet adheres to the left wall of the main pulmonary artery. When right ventricular ejection is absent in pulmonary atresia, the ductal jet streams down the right wall of the pulmonary artery to the pulmonary valve, reverses, and maintains a parallel column back toward the bifurcation. If the reversed flow is mistaken for ejection from the right ventricle, the diagnosis of pulmonary atresia may be missed. PMID:10082354

  18. Analysis of Arterial and Venous Blood Gases in Healthy Gyr Falcons ( Falco rusticolus ) Under Anesthesia.

    Science.gov (United States)

    Raghav, Raj; Middleton, Rachael; BSc, Rinshiya Ahamed; Arjunan, Raji; Caliendo, Valentina

    2015-12-01

    Arterial and venous blood gas analysis is useful in the assessment of tissue oxygenation and ventilation and in diagnosis of metabolic and respiratory derangements. It can be performed with a relatively small volume of blood in avian patients under emergency situations. Arterial and venous blood gas analysis was performed in 30 healthy gyr falcons ( Falco rusticolus ) under anaesthesia to establish temperature-corrected reference intervals for arterial blood gas values and to compare them to temperature-corrected venous blood gas values with a portable point-of-care blood gas analyzer (i-STAT 1, Abbott Laboratories, Abbott Park, IL, USA). Statistically significant differences were observed between the temperature-corrected values of pH, partial pressure of carbon dioxide (Pco2), and partial pressure of oxygen (Po2) and the corresponding nontemperature-corrected values of these parameters in both arterial and venous blood. Values of temperature-corrected pH, temperature-corrected Pco2, bicarbonate concentrations, and base excess of extra cellular fluid did not differ significantly between arterial and venous blood, suggesting that, in anesthetized gyr falcons, venous blood gas analysis can be used in place of arterial blood gas analysis in clinical situations. Values for hematocrit, measured by the point-of-care analyzer, were significantly lower compared with those obtained by the microhematocrit method. PMID:26771318

  19. Ocular Blood Flow and Normal Tension Glaucoma

    Directory of Open Access Journals (Sweden)

    Ning Fan

    2015-01-01

    Full Text Available Normal tension glaucoma (NTG is known as a multifactorial optic neuropathy characterized by progressive retinal ganglion cell death and glaucomatous visual field loss, even though the intraocular pressure (IOP does not exceed the normal range. The pathophysiology of NTG remains largely undetermined. It is hypothesized that the abnormal ocular blood flow is involved in the pathogenesis of this disease. A number of evidences suggested that the vascular factors played a significant role in the development of NTG. In recent years, the new imaging techniques, fluorescein angiography, color Doppler imaging (CDI, magnetic resonance imaging (MRI, and laser speckle flowgraphy (LSFG, have been used to evaluate the ocular blood flow and blood vessels, and the impaired vascular autoregulation was found in patients with NTG. Previous studies showed that NTG was associated with a variety of systemic diseases, including migraine, Alzheimer’s disease, primary vascular dysregulation, and Flammer syndrome. The vascular factors were involved in these diseases. The mechanisms underlying the abnormal ocular blood flow in NTG are still not clear, but the risk factors for glaucomatous optic neuropathy likely included oxidative stress, vasospasm, and endothelial dysfunction.

  20. Effect of inhibition of prostaglandin synthesis on breathing movements and pulmonary blood flow in fetal sheep.

    Science.gov (United States)

    Savich, R D; Guerra, F A; Lee, C C; Kitterman, J A

    1995-02-01

    During transition from fetal to extrauterine life, respiration increases in incidence and magnitude as pulmonary blood flow dramatically increases. To determine whether alterations in pulmonary blood flow in utero are directly related to alterations in fetal breathing movements (FBM), we studied six chronically instrumented fetal sheep late in gestation to assess the effects of continuous FBM caused by a 4-h infusion of meclofenamate, a prostaglandin synthase inhibitor, on mean pulmonary blood flow to the fetus. We found a striking increase in FBM from 46 +/- 15% (SD) of the time during control to > 85% of the time by 1 h (P < 0.001), with the fetuses exhibiting continuous FBM by the last 1 h of infusion. The mean pulmonary blood flow also increased significantly during the first 90 min of the infusion as the incidences of FBM were increasing (26 +/- 14 and 56 +/- 23 ml.min-1.kg-1 for control and infusion, respectively; P < 0.01). Despite the simultaneous initial increase in FBM and mean pulmonary blood flow, the increase in left pulmonary artery blood flow was not sustained and decreased back to baseline by 2 h, even though the incidence of FBM continued to increase at this time. During the infusion, the mean pulmonary blood flow was not different between the presence or absence of FBM. There were no changes in fetal heart rate or pulmonary or systemic blood pressures during the infusion nor in arterial pH or blood gas tensions. We conclude that this increase in mean pulmonary blood flow in utero was not solely related to the increase in breathing movements. PMID:7759422

  1. Cerebral blood flow tomography with xenon-133

    DEFF Research Database (Denmark)

    Lassen, N A

    1985-01-01

    Cerebral blood flow (CBF) can be measured tomographically by inhalation of Xenon-133. The calculation is based on taking a sequence of tomograms during the wash-in and wash-out phase of the tracer. Due to the dynamic nature of the process, a highly sensitive and fast moving single photon emission...... other tracers for CBF tomography using SPECT is summarized with emphasis on the 99mTc chelates that freely pass the intact blood-brain barrier. The highly sensitive brain-dedicated SPECT systems described are a prerequisite for achieving high resolution tomograms with such tracers....

  2. Secondary flow structure in a model curved artery: 3D morphology and circulation budget analysis

    Science.gov (United States)

    Bulusu, Kartik V.; Plesniak, Michael W.

    2015-11-01

    In this study, we examined the rate of change of circulation within control regions encompassing the large-scale vortical structures associated with secondary flows, i.e. deformed Dean-, Lyne- and Wall-type (D-L-W) vortices at planar cross-sections in a 180° curved artery model (curvature ratio, 1/7). Magnetic resonance velocimetry (MRV) and particle image velocimetry (PIV) experiments were performed independently, under the same physiological inflow conditions (Womersley number, 4.2) and using Newtonian blood-analog fluids. The MRV-technique performed at Stanford University produced phase-averaged, three-dimensional velocity fields. Secondary flow field comparisons of MRV-data to PIV-data at various cross-sectional planes and inflow phases were made. A wavelet-decomposition-based approach was implemented to characterize various secondary flow morphologies. We hypothesize that the persistence and decay of arterial secondary flow vortices is intrinsically related to the influence of the out-of-plane flow, tilting, in-plane convection and diffusion-related factors within the control regions. Evaluation of these factors will elucidate secondary flow structures in arterial hemodynamics. Supported by the National Science Foundation under Grant Number CBET-0828903, and GW Center for Biomimetics and Bioinspired Engineering (COBRE). The MRV data were acquired at Stanford University in collaboration with Christopher Elkins and John Eaton.

  3. Blood flow and muscle oxygenation during low, moderate, and maximal sustained isometric contractions.

    Science.gov (United States)

    McNeil, Chris J; Allen, Matti D; Olympico, Eric; Shoemaker, J Kevin; Rice, Charles L

    2015-09-01

    A reduction of blood flow to active muscle will precipitate fatigue, and sustained isometric contractions produce intramuscular and compartmental pressures that can limit flow. The present study explored how blood flow and muscle oxygenation respond to isometric contractions at low, moderate, and maximal intensities. Over two visits, 10 males (26 ± 2 yr; means ± SD) performed 1-min dorsiflexion contractions at 30, 60, and 100% of maximal voluntary contraction (MVC) torque. Doppler ultrasound of the anterior tibial artery was used to record arterial diameter and mean blood velocity and to calculate absolute blood flow. The tissue oxygenation index (TOI) of tibialis anterior was acquired with near-infrared spectroscopy (NIRS). There was a progressive increase in blood flow at 30% MVC (peak of 289 ± 139% resting value), no change from rest until an increase in the final 10 s of exercise at 60% MVC (peak of 197 ± 102% rest), and an initial decrease (59 ± 30% resting value) followed by a progressive increase at 100% MVC (peak of 355 ± 133% rest). Blood flow was greater at 30 and 100% than 60% MVC during the last 30 s of exercise. TOI was ∼63% at rest and, within 30 s of exercise, reached steady-state values of ∼42%, ∼22%, and ∼22% for 30, 60, and 100% MVC, respectively. Even maximal contraction of the dorsiflexors is unable to cause more than a transient decrease of flow in the anterior tibial artery. Unlike dynamic or intermittent isometric exercise, our results indicate blood flow is not linearly graded with intensity or directly coupled with oxygenation during sustained isometric contractions. PMID:26084698

  4. Application of the iodide clearance technique to monitor local changes in periodontal ligament blood flow

    International Nuclear Information System (INIS)

    The present study was undertaken to validate a newly developed technique for monitoring blood flow changes with local clearance of 125I in the periodontal ligament (PDL). The tracer substance was allowed to diffuse into the intact PDL via a cavity that was drilled from the root canal out towards the root surface. Electric stimulation of the cervical sympathetic trunk caused a reduction in the clearance rate of the tracer from the cavity in a frequency-dependent manner. Intra-arterial infusions of noradrenaline also induced decreases in clearance rate. Intra-arterial infusions of the vasodilators substance P and vasoactive intestinal peptide induced increases in clearance rate. The present technique makes it possible to monitor local blood flow changes in the intact PDL during both decreases and increases in blood flow

  5. Treating hepatic carcinoma with internal mammary artery blood supply through transcatheter arterial chemoembolization

    International Nuclear Information System (INIS)

    Objective: To study blood supply by the internal mammary artery (IMA)for hepatic carcinoma and evaluate the efficacy and safety of transcatheter arterial chemoembolization (TACE)via IMA. Methods: 86 cases of hepatic cancer(HCC) fed by the IMA underwent TACE of the IMA. All of the patients had previously undergone several TACE for HCC. 16 patients had undertaken percutaneous microwave coagulation therapy in addition to TAE. 4 patients had a history of surgery for upper abdomen. Plain and enhanced CT and MRI scannings were performed before operation. Internal mammary arteriography was carried out during the interventional procedure to clarify the feeding range and then the superselected catheterization of the feeding branch was done with TACE. The IMA angiographic features, tumor location, clinical observation, laboratory tests, imageology were evaluated, and finally were correlated with the angiographic findings of the IMA. Results: All lesions were massive type and located at the ventral aspect and subcapsular region of the liver: 57 cases in segment 4, 5, 8, and 29 cases in segment 5, 7, 8. Recurrent HCCs were supplied by the right IMA in 80 cases, from the left IMA in 5 cases and with the bilateral IMA in 1 case. Lipiodol-TACE of the IMA for HCC can be performed without skin complications in cases of subselective catheterization. Conclusion Tumors located ventrally and superficially in the liver may recruit blood supply through IMA collaterals, often occurring in massive type of HCC after several times of TACE. TACE of IMA is safe and has become technically feasible in almost all patients, although cutaneous damage should be cautious during the interventional procedure. (authors)

  6. Role of cerebral blood flow in extreme breath holding

    Directory of Open Access Journals (Sweden)

    Bain Anthony R.

    2016-01-01

    Full Text Available The role of cerebral blood flow (CBF on a maximal breath-hold (BH in ultra-elite divers was examined. Divers (n = 7 performed one control BH, and one BH following oral administration of the non-selective cyclooxygenase inhibitor indomethacin (1.2 mg/kg. Arterial blood gases and CBF were measured prior to (baseline, and at BH termination. Compared to control, indomethacin reduced baseline CBF and cerebral delivery of oxygen (CDO2 by about 26% (p < 0.01. Indomethacin reduced maximal BH time from 339 ± 51 to 319 ± 57 seconds (p = 0.04. In both conditions, the CDO2 remained unchanged from baseline to the termination of apnea. At BH termination, arterial oxygen tension was higher following oral administration of indomethacin compared to control (4.05 ± 0.45 vs. 3.44 ± 0.32 kPa. The absolute increase in CBF from baseline to the termination of apnea was lower with indomethacin (p = 0.01. These findings indicate that the impact of CBF on maximal BH time is likely attributable to its influence on cerebral H+ washout, and therefore central chemoreceptive drive to breathe, rather than to CDO2.

  7. In vitro and in vivo studies of pulmonary artery flow

    International Nuclear Information System (INIS)

    A variety of interesting intracardiac flow patterns have been recorded by pulsed and continuous wave Doppler technologies in humans with heart disease. Some of these patterns have, in fact, been difficult to explain and are now more easily understood using color Doppler flow mapping systems which show the spatial location of flow. The authors performed a number of studies in patients, as well as studies in in vitro systems to model some of the phenomenon that the authors observed in the pulmonary artery. Their studies with Doppler flow mapping in the clinical situation, in the in vitro model, and in the animal models of congenital heart disorders lend insights into the complex hydrodynamics present in the pulmonary artery

  8. Multiscale Modeling of Blood Flow: Coupling Finite Elements with Smoothed Dissipative Particle Dynamics

    KAUST Repository

    Moreno, Nicolas

    2013-06-01

    A variational multi scale approach to model blood flow through arteries is proposed. A finite element discretization to represent the coarse scales (macro size), is coupled to smoothed dissipative particle dynamics that captures the fine scale features (micro scale). Blood is assumed to be incompressible, and flow is described through the Navier Stokes equation. The proposed cou- pling is tested with two benchmark problems, in fully coupled systems. Further refinements of the model can be incorporated in order to explicitly include blood constituents and non-Newtonian behavior. The suggested algorithm can be used with any particle-based method able to solve the Navier-Stokes equation.

  9. Simulation of Local Blood Flow in Human Brain under Altered Gravity

    Science.gov (United States)

    Kim, Chang Sung; Kiris, Cetin; Kwak, Dochan

    2003-01-01

    In addition to the altered gravitational forces, specific shapes and connections of arteries in the brain vary in the human population (Cebral et al., 2000; Ferrandez et al., 2002). Considering the geometric variations, pulsatile unsteadiness, and moving walls, computational approach in analyzing altered blood circulation will offer an economical alternative to experiments. This paper presents a computational approach for modeling the local blood flow through the human brain under altered gravity. This computational approach has been verified through steady and unsteady experimental measurements and then applied to the unsteady blood flows through a carotid bifurcation model and an idealized Circle of Willis (COW) configuration under altered gravity conditions.

  10. Laser Doppler flowmetry is valid for measurement of cerebral blood flow autoregulation lower limit in rats

    DEFF Research Database (Denmark)

    Tonnesen, Jan; Pryds, Anders; Larsen, Erik Hviid;

    2005-01-01

    Laser Doppler flowmetry (LDF) is a recent technique that is increasingly being used to monitor relative changes in cerebral blood flow whereas the intra-arterial 133xenon injection technique is a well-established method for repeated absolute measurements of cerebral blood flow. The aim of this st......Laser Doppler flowmetry (LDF) is a recent technique that is increasingly being used to monitor relative changes in cerebral blood flow whereas the intra-arterial 133xenon injection technique is a well-established method for repeated absolute measurements of cerebral blood flow. The aim...... in similar results. We conclude that even though LDF overestimated CBF during haemorrhagic shock caused by controlled haemorrhage, the lower limit autoregulation was correctly identified. The laser Doppler technique provides a reliable method for detection of a wide range of cerebral blood flow changes under...... CO2 challenge. Haemodilution influences the two methods differently causing relative overestimation of blood flow by the laser Doppler technique compared to the 133xenon method....

  11. MRI of cerebral blood flow under hyperbaric conditions in rats.

    Science.gov (United States)

    Cardenas, Damon P; Muir, Eric R; Duong, Timothy Q

    2016-07-01

    Hyperbaric oxygen (HBO) therapy has a number of clinical applications. However, the effects of acute HBO on basal cerebral blood flow (CBF) and neurovascular coupling are not well understood. This study explored the use of arterial spin labeling MRI to evaluate changes in baseline and forepaw stimulus-evoked CBF responses in rats (n = 8) during normobaric air (NB), normobaric oxygen (NBO) (100% O2 ), 3 atm absolute (ATA) hyperbaric air (HB) and 3 ATA HBO conditions. T1 was also measured, and the effects of changes in T1 caused by increasing oxygen on the CBF calculation were investigated. The major findings were as follows: (i) increased inhaled oxygen concentrations led to a reduced respiration rate; (ii) increased dissolved paramagnetic oxygen had significant effects on blood and tissue T1 , which affected the CBF calculation using the arterial spin labeling method; (iii) the differences in blood T1 had a larger effect than the differences in tissue T1 on CBF calculation; (iv) if oxygen-induced changes in blood and tissue T1 were not taken into account, CBF was underestimated by 33% at 3 ATA HBO, 10% at NBO and HBO, HB and NBO were similar (p > 0.05) and all were higher than CBF under NB by ~40% (p HBO, similar to NB, supporting the notion that activation-induced CBF regulation in the brain does not operate through an oxygen-sensing mechanism. CBF MRI provides valuable insights into the effects of oxygen on basal CBF and neurovascular coupling under hyperbaric conditions. Copyright © 2016 John Wiley & Sons, Ltd. PMID:27192391

  12. Noninvasive optical characterization of muscle blood flow, oxygenation, and metabolism in women with fibromyalgia

    OpenAIRE

    Shang, Yu; Gurley, Katelyn; Symons, Brock; Long, Douglas; Srikuea, Ratchakrit; Crofford., Leslie J.; Peterson, Charlotte A.; Yu, Guoqiang

    2012-01-01

    Introduction Women with fibromyalgia (FM) have symptoms of increased muscular fatigue and reduced exercise tolerance, which may be associated with alterations in muscle microcirculation and oxygen metabolism. This study used near-infrared diffuse optical spectroscopies to noninvasively evaluate muscle blood flow, blood oxygenation and oxygen metabolism during leg fatiguing exercise and during arm arterial cuff occlusion in post-menopausal women with and without FM. Methods Fourteen women with...

  13. Regional cerebral blood flow after hemorrhagic hypotension in the preterm, near-term, and newborn lamb.

    Science.gov (United States)

    Szymonowicz, W; Walker, A M; Yu, V Y; Stewart, M L; Cannata, J; Cussen, L

    1990-10-01

    Developmental changes in regional cerebral blood flow (CBF) responses to hemorrhagic hypotension during normoxia and normocapnia were determined using radioactively labeled microspheres to measure flow to the cortex, brainstem, cerebellum, white matter, caudate nucleus, and choroid plexus in three groups of chronically catheterized lambs: 90- to 100-d preterm fetal lambs (n = 9); 125- to 136-d near-term fetal lambs (n = 9); and newborn lambs 5- to 35-d-old (n = 8). Heart rate, central venous pressure, and arterial blood pressure were monitored continuously and arterial blood gas tensions, pH, Hb, and oxygen saturation together with regional CBF were measured periodically. Hemorrhagic hypotension produced a mean decrease in arterial blood pressure of 27 +/- 4, 23 +/- 2, and 41 +/- 4% in the three groups, respectively, whereas reinfusion of the lamb's blood resulted in a return to control blood pressure within 3% in all three groups. In the pre-term fetal lamb, CBF decreased significantly in all regions during hypotension. In the near-term fetal lamb, only blood flow to the cortex decreased significantly during hypotension. In the newborn lamb, only the choroid plexus demonstrated a significant decrease in blood flow during hypotension. The lower limit of regional CBF autoregulation was identical to the resting mean arterial pressure in fetal life but significantly lower in newborn lambs. These experiments demonstrate for the first time that vulnerability to hypotension decreases with increasing maturity and that the brainstem, the phylogenetically oldest region of the brain, is the least vulnerable to the effects of hypotension at any age in the lamb model. PMID:2235134

  14. Cutaneous blood flow rate in areas with and without arteriovenous anastomoses during exercise

    DEFF Research Database (Denmark)

    Midttun, M.; Sejrsen, Per

    Arteriovenous anastomoses, capillaries, cutaneous bllod flow rate, exercise, finger blood flow, skin blood flow......Arteriovenous anastomoses, capillaries, cutaneous bllod flow rate, exercise, finger blood flow, skin blood flow...

  15. Alteration of pulmonary blood flow in tetralogy of Fallot

    International Nuclear Information System (INIS)

    The pulmonary blood distribution was examined in 17 patients with tetralogy of Fallot (TOF) pre and postoperatively with macroaggregates of 99mTC-labeled human serum albumin. Most of the patients with TOF demonstrated an abnormal preoperative distribution pattern. The abnormalities included not only an unbalanced distribution between the right and left lungs but also a maldistribution of peripheral vessels in each lung. The right/left lung counts ratio and pulmonary peripheral index (calculated in order to express the severity of peripheral maldistribution) correlated neither to the diameter nor the cross-sectional area of either right or left pulmonary arteries which were measured angiographically. Postoperatively, the pulmonary blood was shunted toward the developed side of the lung which further contributed to maldistribution of blood flow and unbalanced pulmonary growth. Since the patients with an unbalanced pulmonary blood distribution demonstrated a higher right ventricular pressure one year after the operation, a palliative operation facilitating the growth of the underdeveloped side of the lung might be considered as an effective procedure to precede intracardiac repair. (author)

  16. Regional blood flow studies with radioisotopes

    International Nuclear Information System (INIS)

    The methodological approaches to blood flow analysis include (1) diffusible indicator methods, (2) clearance techniques and (3) nondiffusible indicator methods. In each case, accurate measurements of blood flow can be obtained by developing mathematical models which relate the time-dependent observation derived from following the fate of a radiotracer as a function of time to the physiological process itself. Application of these models to biological systems involves constraints and necessitates compromises which may affect the validity of the measurements. Nevertheless, when these techniques are carefully applied and adequately validated, they have provided critical physiological information about such organ systems as the brain and kidney and promise to provide diagnostic information in patients with suspected coronary and peripheral vascular disease

  17. Deterministic Aperiodic Sickle Cell Blood Flows

    Science.gov (United States)

    Atsaves, Louis; Harris, Wesley

    2013-11-01

    In this paper sickle cell blood flow in the capillaries is modeled as a hydrodynamical system. The hydrodynamical system consists of the axisymmetric unsteady, incompressible Navier-Stokes equations and a set of constitutive equations for oxygen transport. Blood cell deformation is not considered in this paper. The hydrodynamical system is reduced to a system of non-linear partial differential equations that are then transformed into a system of three autonomous non-linear ordinary differential equations and a set of algebraic equations. We examine the hydrodynamical system to discern stable/unstable, periodic/nonperiodic, reversible/irreversible properties of the system. The properties of the solutions are driven in large part by the coefficients of the governing system of equations. These coefficients depend on the physiological properties of the sickle cell blood. The chaotic nature of the onset of crisis in sickle cell patients is identified. Research Assistant.

  18. Measurement of cerebral blood flow in the pig by the Xe-133 clearance technique

    International Nuclear Information System (INIS)

    The Xe-133 clearance technique is used to measure cerebral blood flow in the pig, which often serves as an experimental animal for cardiovascular research. The clearance curves are fitted by a two-exponential model. However, the fitted parameters are incompatible with a two-compartmental model: the values found for the parameters depend on the length of the clearance curve analysed. The discrepancies are thought to be consequences of the heterogeneity of cerebral blood flow and of mathematical problems of parameter identification. The non-validity of the relative weight of the fast clearance component as an anatomical or functional parameter is demonstrated. The use of the mean time constant, mean transit time, mean decay constant and initial slope for determination of cerebral blood flow rates is discussed. The mean cerebral blood flow of the anaesthetized pig measured by the clearance technique is found to be lower than the blood flow measured by means of a flow probe around the common carotid artery (with the external carotid artery tied off). The existence of a significant arteriovenous shunt flow is postulated. (orig.)

  19. Blockade of the MEK/ERK pathway with a raf inhibitor prevents activation of pro-inflammatory mediators in cerebral arteries and reduction in cerebral blood flow after subarachnoid hemorrhage in a rat model

    DEFF Research Database (Denmark)

    Maddahi, Aida; Ansar, Saema; Chen, Qingwen;

    2011-01-01

    /ERK (MEK)/extracellular signal-regulated kinase (ERK) pathway upstream with a specific raf inhibitor would prevent SAH-induced activation of the cerebrovascular inflammatory response. The raf inhibitor SB-386023-b was injected intracisternally in our rat model at 0, 6, or 12 hours after the SAH. After 48......Cerebral ischemia that develops after subarachnoid hemorrhage (SAH) carries high morbidity and mortality. Inflammatory mediators are involved in the development of cerebral ischemia through activation of the mitogen-activated protein kinase pathway. We hypothesized that blockade of the MAPkinase....... Cerebral blood flow (CBF) was measured using autoradiography. Protein levels of MMP-9, TIMP-1, iNOS, IL-6, and IL-1β were increased after SAH, as were mRNA levels of IL-6, MMP-9, and TIMP-1. After SAH, pERK1/2 was increased, but CBF was reduced. Treatment with SB-386023-b at 0 or 6 hours after SAH...

  20. Blood flow-restricted exercise in space

    OpenAIRE

    Hackney, Kyle J; Everett, Meghan; Scott, Jessica M; Ploutz-Snyder, Lori

    2012-01-01

    Prolonged exposure to microgravity results in chronic physiological adaptations including skeletal muscle atrophy, cardiovascular deconditioning, and bone demineralization. To attenuate the negative consequences of weightlessness during spaceflight missions, crewmembers perform moderate- to high-load resistance exercise in conjunction with aerobic (cycle and treadmill) exercise. Recent evidence from ground-based studies suggests that low-load blood flow-restricted (BFR) resistance exercise tr...

  1. Surfactant bolus instillation: effects of different doses on blood pressure and cerebral blood flow velocities

    OpenAIRE

    Rey, M.; Segerer, Hugo; Kiessling, C.; Obladen, Michael

    1994-01-01

    Fifteen preterm infants suffering from respiratory distress syndrome were randomly allocated to receive either high-dose (200 mg/kg) or low-dose (100 mg/kg) surfactant treatment. Retreatments were done with the low dose. Blood pressure, blood gases and cerebral blood flow velocities were determined before and after 24 bolus instillations. With the high dose mean blood pressure and mean cerebral blood flow velocity dropped significantly. With the low dose only mean cerebral blood flow velocity...

  2. Changes in human cerebral blood flow and myocardial blood flow during mental stress measured by dual positron emission tomography

    International Nuclear Information System (INIS)

    Mental stress causes a substantial sympathetic response, thus increasing myocardial blood flow (MBF). However, the effects of mental stress on global cerebral blood flow (CBF) have not been elucidated. In this study, changes in CBF and MBF in relation to mental stress were measured by a dual positron emission tomography system that can measure CBF and MBF simultaneously. CBF and MBF were measured in 10 healthy men with O-15 labeled water at rest (baseline) and during the performance of a mental task that required subtraction of 7s serially from a four-digit number. Baseline global CBF and values obtained during the mental activity were 0.42±0.05 and 0.45±0.06 ml/ml/min (mean±SD), respectively. Baseline MBF and values obtained during mental activity were 0.61±0.12 and 1.09±0.58 ml/ml/min, respectively. Percent changes in CBF and MBF during mental stress were 6±11% and 78±73%, respectively. No significant difference was observed in arterial carbon dioxide tension (PaCO2) level between the mental stress and baseline conditions. MBF, blood pressure, heart rate, and plasma concentrations of adrenaline and noradrenaline increased significantly during mental stress. Sympathetic stimulation is reported to cause cerebral vasoconstriction and reduce CBF in animals. Although such a sympathetic response was observed in relation to mental stress, no significant change in CBF was observed in our subjects. (author)

  3. Regional cerebral blood flow in schizophrenia

    International Nuclear Information System (INIS)

    Regional cerebral blood flow (rCBF) was measured at rest using the 133Xe inhalation technique in 40 DSM-III-diagnosed schizophrenics (22 males, 18 females: mean age 35.0 years, range 20-49 years) and 31 age-and sex-matched normal controls (16 males, 15 females: mean age 34.3 years, range 21-49 years). The absolute value (AV) and the percent value (PV) of the rCBF in schizophrenics were compared with those in controls. Correlations between rCBF and the Brief Psychiatric Rating Scale (BPRS) scores or the performance of Wisconsin Card Sorting Test (WCST) were examined in schizophrenics. Schizophrenics showed significantly lower AVs in all brain regions examined and a significantly lower PV in the left superior frontal region than controls. The hyperfrontal rCBF distribution which was found in both hemispheres in controls, was absent in the left hemisphere in schizophrenics. In schizophrenics, superior frontal blood flows were significantly negatively correlated with the negative symptom scores of the BPRS but not with the total scores and the positive symptom scores of the BPRS. In schizophrenics, inferior frontal blood flows were significantly correlated with the number of sorting categories achieved. These results indicate that rCBF in schizophrenia is reduced in the whole brain and especially in the left superior frontal region. These findings suggest a frontal lobe dysfunction in schizophrenia. (author)

  4. Red blood cell in simple shear flow

    Science.gov (United States)

    Chien, Wei; Hew, Yayu; Chen, Yeng-Long

    2013-03-01

    The dynamics of red blood cells (RBC) in blood flow is critical for oxygen transport, and it also influences inflammation (white blood cells), thrombosis (platelets), and circulatory tumor migration. The physical properties of a RBC can be captured by modeling RBC as lipid membrane linked to a cytoskeletal spectrin network that encapsulates cytoplasm rich in hemoglobin, with bi-concave equilibrium shape. Depending on the shear force, RBC elasticity, membrane viscosity, and cytoplasm viscosity, RBC can undergo tumbling, tank-treading, or oscillatory motion. We investigate the dynamic state diagram of RBC in shear and pressure-driven flow using a combined immersed boundary-lattice Boltzmann method with a multi-scale RBC model that accurately captures the experimentally established RBC force-deformation relation. It is found that the tumbling (TU) to tank-treading (TT) transition occurs as shear rate increases for cytoplasm/outer fluid viscosity ratio smaller than 0.67. The TU frequency is found to be half of the TT frequency, in agreement with experiment observations. Larger viscosity ratios lead to the disappearance of stable TT phase and unstable complex dynamics, including the oscillation of the symmetry axis of the bi-concave shape perpendicular to the flow direction. The dependence on RBC bending rigidity, shear modulus, the order of membrane spectrin network and fluid field in the unstable region will also be discussed.

  5. Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement

    Directory of Open Access Journals (Sweden)

    Komine Hidehiko

    2012-02-01

    Full Text Available Abstract Background Arterial stiffness is a major contributor to cardiovascular diseases. Because current methods of measuring arterial stiffness are technically demanding, the purpose of this study was to develop a simple method of evaluating arterial stiffness using oscillometric blood pressure measurement. Methods Blood pressure was conventionally measured in the left upper arm of 173 individuals using an inflatable cuff. Using the time series of occlusive cuff pressure and the amplitudes of pulse oscillations, we calculated local slopes of the curve between the decreasing cuff pressure and corresponding arterial volume. Whole pressure-volume curve was derived from numerical integration of the local slopes. The curve was fitted using an equation and we identified a numerical coefficient of the equation as an index of arterial stiffness (Arterial Pressure-volume Index, API. We also measured brachial-ankle (baPWV PWV and carotid-femoral (cfPWV PWV using a vascular testing device and compared the values with API. Furthermore, we assessed carotid arterial compliance using ultrasound images to compare with API. Results The slope of the calculated pressure-volume curve was steeper for compliant (low baPWV or cfPWV than stiff (high baPWV or cfPWV arteries. API was related to baPWV (r = -0.53, P r = -0.49, P r = 0.32, P Conclusions These results suggest that our method can simply and simultaneously evaluate arterial stiffness and blood pressure based on oscillometric measurements of blood pressure.

  6. Blood flow and oxygenation in peritendinous tissue and calf muscle during dynamic exercise in humans

    DEFF Research Database (Denmark)

    Boushel, R; Langberg, Henning; Green, Stefan Mathias; Skovgaard, D; Bulow, J; Kjaer, M

    1. Circulation around tendons may act as a shunt for muscle during exercise. The perfusion and oxygenation of Achilles' peritendinous tissue was measured in parallel with that of calf muscle during exercise to determine (1) whether blood flow is restricted in peritendinous tissue during exercise...... output by dye dilution, arterial pressure by an arterial catheter-transducer, and muscle and peritendinous O2 saturation by spatially resolved spectroscopy (SRS). 3. Calf blood flow rose 20-fold with exercise, reaching 44 +/- 7 ml (100 g)-1 min-1 (mean +/- s.e.m. ) at 9 W, while Achilles' peritendinous...... flow increased (7-fold) to 14 +/- 4 ml (100 g)-1 min-1, which was 18 % of the maximal flow established during reactive hyperaemia. SRS-O2 saturation fell both in muscle (from 66 +/- 2 % at rest to 57 +/- 3 %, P <0.05) and in peritendinous regions (58 +/- 4 to 52 +/- 4 %, P <0.05) during exercise along...

  7. Temporal patterns of blood flow and nitric oxide synthase expression affect macrophage accumulation and proliferation during collateral growth

    OpenAIRE

    Sager Hendrik B; Middendorff Ralf; Rauche Kim; Weil Joachim; Lieb Wolfgang; Schunkert Heribert; Ito Wulf D

    2010-01-01

    Abstract Background The involvement of collateral blood flow/fluid shear stress, nitric oxide (NO), and macrophages during collateral growth (arteriogenesis) is established, but their interplay remains paradoxical. Methods In order to further elucidate the "fluid shear stress/NO/macrophage" paradox, we investigated the time course of collateral blood flow (using a Doppler flow probe) and NOS expression (immunohistochemistry, Western blot) in growing rat collateral vessels after femoral artery...

  8. Direction of flow in posterior communicating artery on magnetic resonance angiography in patients with occipital lobe infarcts

    NARCIS (Netherlands)

    Jongen, JCF; Franke, CL; Ramos, LMP; Wilmink, JT; van Gijn, J

    2004-01-01

    Background and Purpose - In some people the blood supply to the posterior cerebral artery occurs partly or even exclusively via the carotid system. This anatomic configuration may influence the risk of occipital lobe infarction. We studied the presence and direction of flow in the posterior communic

  9. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions. PMID:26053731

  10. Normalization of thyroid blood flow in Graves' hyperthyroidism following radioactive iodine therapy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, D.C.S.; Woodcock, J.P.; Shedden, E.J.; Lazarus, J.H.; Wheeler, M.H.; McGregor, A.M. (University Hospital of Wales, Cardiff (UK). Medical Physics Dept.)

    1990-05-01

    In a group of 12 patients with Graves' hyperthyroidism, administration of 514 {plus minus} 43 (mean {plus minus} SD) MBq iodine-131 was associated with a fall of superior thyroid artery (STA) blood flow in two at 6 months and in eight at 11 months. The reduction in time-averaged velocity at 11 months correlated with the reduction in FT4 and in FT3 at this time. In four patients who had persistent elevated STA blood flow, two were still hyperthyroid. The diameter of the STA was unchanged at 6 months and only half the patients had reduction of their STA size at 11 months after radioiodine (RAI) therapy. These data indicate that normalization of STA blood flow precedes normalization of STA size in patients treated with RAI. Further work is required to determine whether STA blood flow measurements are of predictive value in treatment outcome. (author).

  11. Renal blood flow during dynamic exercise in trained and untrained swine

    International Nuclear Information System (INIS)

    To determine the effects of acute and chronic exercise on renal blood flow, we studied 13 trained and 13 untrained swine at rest and during treadmill exercise. Animals were instrumented with aortic, left artrial and pulmonary arterial catheters. Trained animals were capable of running one hr per day, five days per wk by the end of 9 to 12 wk of training. We injected 15 um radiolabeled microspheres via a left atrial catheter during resting, moderate and maximal exercise conditions. Animals in the training group exhibited a 29% increase in maximal oxygen consumption (n = 7). Renal blood flow was not different between groups for the three conditions. However, trained animals exhibited a trend towards a progressive decrease in renal blood flow with increasing exercise intensity. Thus, unlike dogs, swine exhibit adjustments in renal blood flow similar to those observed in humans

  12. Aerobic fitness is associated with greater hippocampal cerebral blood flow in children.

    Science.gov (United States)

    Chaddock-Heyman, Laura; Erickson, Kirk I; Chappell, Michael A; Johnson, Curtis L; Kienzler, Caitlin; Knecht, Anya; Drollette, Eric S; Raine, Lauren B; Scudder, Mark R; Kao, Shih-Chun; Hillman, Charles H; Kramer, Arthur F

    2016-08-01

    The present study is the first to investigate whether cerebral blood flow in the hippocampus relates to aerobic fitness in children. In particular, we used arterial spin labeling (ASL) perfusion MRI to provide a quantitative measure of blood flow in the hippocampus in 73 7- to 9-year-old preadolescent children. Indeed, aerobic fitness was found to relate to greater perfusion in the hippocampus, independent of age, sex, and hippocampal volume. Such results suggest improved microcirculation and cerebral vasculature in preadolescent children with higher levels of aerobic fitness. Further, aerobic fitness may influence how the brain regulates its metabolic demands via blood flow in a region of the brain important for learning and memory. To add specificity to the relationship of fitness to the hippocampus, we demonstrate no significant association between aerobic fitness and cerebral blood flow in the brainstem. Our results reinforce the importance of aerobic fitness during a critical period of child development. PMID:27419884

  13. The effect of ergotamine and dihydroergotamine on cerebral blood flow in man

    DEFF Research Database (Denmark)

    Andersen, A R; Tfelt-Hansen, P; Lassen, N A

    1987-01-01

    The effects of ergotamine and dihydroergotamine on cerebral blood flow was investigated 4 hours after i.v. injection as these drugs might be of importance for migraine treatment. Eight normal male volunteers (not suffering from migraine) received 0.5 mg ergotamine and 1 mg dihydroergotamine i.......v. Cerebral blood flow was measured by the xenon-133 inhalation method and single-photon-emission computerized tomography before and after intravenous acetazolamide administration (1 g). Cerebral blood flow was measured before and 4 hours after ergotamine and dihydroergotamine administration. Strain......-gauge measurements of toe-arm systolic gradients were used to monitor the effect of the drug on leg arteries. Mean hemispheric and regional cerebral blood flow was unchanged after either drug (mean +/- SEM, ml/100 g/min): for ergotamine, 57 +/- 3 before and 57 +/- 3 at 4 hours; for dihydroergotamine, 54 +/- 2 before...

  14. Fluid-structure interaction in blood flow capturing non-zero longitudinal structure displacement

    OpenAIRE

    Bukac, Martina; Canic, Suncica; Glowinski, Roland; Tambaca, Josip; Quaini, Annalisa

    2012-01-01

    We present a new model and a novel loosely coupled partitioned numerical scheme modeling fluid-structure interaction (FSI) in blood flow allowing non-zero longitudinal displacement. Arterial walls are modeled by a {linearly viscoelastic, cylindrical Koiter shell model capturing both radial and longitudinal displacement}. Fluid flow is modeled by the Navier-Stokes equations for an incompressible, viscous fluid. The two are fully coupled via kinematic and dynamic coupling conditions. Our numeri...

  15. Effects of Antenatal Magnesium Exposure on Intestinal Blood Flow and Outcome in Preterm Neonates

    OpenAIRE

    Gürsoy, Tuğba; İmamoğlu, Ebru Yalın; Ovalı, Fahri; Karatekin, Güner

    2015-01-01

    Objective This study aims to investigate the effects of antenatal magnesium sulfate on intestinal blood flow in preterm neonates. Study Design In this prospective case-match study, 25 preterm neonates exposed to magnesium sulfate antenatally were included (study group). Overall, 25 gestational age-matched neonates who had no exposure to magnesium constituted the control group. Serial daily Doppler flow measurements of superior mesenteric artery (SMA) were performed. The time to reach full fee...

  16. Optimal velocity encoding during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography

    Institute of Scientific and Technical Information of China (English)

    Gang Guo; Yonggui Yang; Weiqun Yang

    2011-01-01

    This study investigated the effect of velocity encoding on measurement of brain blood flow and blood volume of inflow and outflow using phase-contrast magnetic resonance angiography. A single two-dimensional phase-contrast magnetic resonance angiography slice was applied perpendicular to the internal carotid artery and the vertebral artery at C2 level. For each subject, the velocity encoding was set from 30 to 90 cm/s with an interval of 10 cm/s for a total of seven settings. Various velocity encodings greatly affected blood flow volume, maximal blood flow velocity and mean blood flow velocity in the internal carotid artery, but did not significantly affect vertebral arteries and jugular veins. When velocity encoding was 60-80 cm/s, the inflow blood volume was 655 ± 118 mL/min, and the outflow volume was 506 ± 186 mL/min. The ratio of outflow/inflow was steady at 0.78-0.83, and there was no aliasing in any of the images. These findings suggest that velocity encodings of 60-80 cm/s should be selected during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography.

  17. Effect of spinal cord compression on local vascular blood flow and perfusion capacity.

    Directory of Open Access Journals (Sweden)

    Mohammed Alshareef

    Full Text Available Spinal cord injury (SCI can induce prolonged spinal cord compression that may result in a reduction of local tissue perfusion, progressive ischemia, and potentially irreversible tissue necrosis. Due to the combination of risk factors and the varied presentation of symptoms, the appropriate method and time course for clinical intervention following SCI are not always evident. In this study, a three-dimensional finite element fluid-structure interaction model of the cervical spinal cord was developed to examine how traditionally sub-clinical compressive mechanical loads impact spinal arterial blood flow. The spinal cord and surrounding dura mater were modeled as linear elastic, isotropic, and incompressible solids, while blood was modeled as a single-phased, incompressible Newtonian fluid. Simulation results indicate that anterior, posterior, and anteroposterior compressions of