WorldWideScience

Sample records for arterial switch procedure

  1. Sudden Death Due to Coronary Artery Lesions Long-term After the Arterial Switch Operation: A Systematic Review.

    NARCIS (Netherlands)

    van Wijk, Sebastiaan W.H.; van der Stelt, Femke; ter Heide, Henriëtte; Schoof, Paul H.; Doevendans, Pieter A.F.M.; Meijboom, Folkert J.; Breur, Johannes M.P.J.

    2017-01-01

    Background The arterial switch operation (ASO) is the preferred procedure for children with dextrotransposition of the great arteries or Taussig-Bing anomaly. Short- as well as long-term outcome of ASO are excellent, but coronary artery stenoses are reported as a common long-term complication. It

  2. Pulmonary Arterial Hypertension and Neonatal Arterial Switch Surgery for Correction of Transposition of the Great Arteries.

    Science.gov (United States)

    Domínguez Manzano, Paula; Mendoza Soto, Alberto; Román Barba, Violeta; Moreno Galdó, Antonio; Galindo Izquierdo, Alberto

    2016-09-01

    There are few reports of the appearance of pulmonary arterial hypertension following arterial switch surgery in the neonatal period to correct transposition of the great arteries. We assessed the frequency and clinical pattern of this complication in our series of patients. Our database was reviewed to select patients with transposition of the great arteries corrected by neonatal arterial switch at our hospital and who developed pulmonary hypertension over time. We identified 2 (1.3%) patients with transposition of the great arteries successfully repaired in the first week of life who later experienced pulmonary arterial hypertension. The first patient was a 7-year-old girl diagnosed with severe pulmonary hypertension at age 8 months who did not respond to medical treatment and required lung transplantation. The anatomic pathology findings were consistent with severe pulmonary arterial hypertension. The second patient was a 24-month-old boy diagnosed with severe pulmonary hypertension at age 13 months who did not respond to medical therapy. Pulmonary hypertension is a rare but very severe complication that should be investigated in all patients with transposition of the great arteries who have undergone neonatal arterial switch, in order to start early aggressive therapy for affected patients, given the poor therapeutic response and poor prognosis involved. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  3. COMPLEX CORONARY PATTERN AFFECTING THE SURGICAL OUTCOME OF ARTERIAL SWITCH OPERATION

    Directory of Open Access Journals (Sweden)

    Amit

    2015-12-01

    Full Text Available BACKGROUND Arterial switch operation (ASO has become the procedure of choice for the transposition of great arteries as well as for Taussig-Bing anomaly. Relocation of coronary arteries remains a technical problem in anatomic correction of the transposed great arteries. The present prospective study is designed to analyse the effect of coronary artery pattern on surgical outcome of arterial switch operation. METHOD From August 2014 to November 2015, total 60 patients underwent ASO. The patients are divided in three groups. Group-A 21 patients with d-TGA with intact ventricle septum (d-TGA intact IVS, in Group-B 33 patients d-TGA with ventricular septal defect (d-TGA, VSD, and in Group C 6 Taussig Bing anomaly. The coronary pattern and outcome is analyzed. RESULTS The overall mortality related to coronary pattern was 5%. The 2 patients died due to Intramural coronary artery leading to post-operative ventricular dysfunction, another patient with single retro pulmonary coronary artery died secondary to low coronary implant leading to kinking in coronary artery and myocardial dysfunction. On 12 monthly follow up, one of the Patients in group A had right pulmonary artery stenosis with gradient of 30 mm of Hg. Another patient in group B had supravalvular gradient of 20 mm of Hg. CONCLUSION The ASO for TGA and Taussig-Bing anomaly has low early and late mortality. However, the mortality is still seen in the patients with Intramural coronary artery and in the patient with single coronary artery with retro pulmonary course.

  4. Myocardial perfusion SPECT in a case of retropulmonary looping of left coronary artery in a baby after arterial switch surgery

    International Nuclear Information System (INIS)

    Padma, Subramanyam; Sundaram, Palaniswamy Shanmuga

    2014-01-01

    Pediatric myocardial perfusion imaging (MPI) is not a routine investigation in an Indian setting due to under referrals and logistic problems. However, MPI is a frequently performed and established modality of investigation in adults for the identification of myocardial ischemia and viability. We report myocardial perfusion scintigraphy in a case of retropulmonary looping of left coronary artery in a baby after arterial switch surgery. Adenosine stress MPI revealed a large infarct involving anterior segment with moderate reversible ischemia of the lateral left ventricular segment. Coronary angiogram later confirmed left main coronary artery ostial occlusion with retrograde collateral supply from dilated right coronary artery

  5. 3D Heart Model and 4D Flow MRI 20 Years after Spiral Arterial Switch Operation.

    Science.gov (United States)

    Sievers, Hans-Hinrich; Kheradvar, Arash; Kramer, Hans-Heiner; Rickers, Carsten

    2016-12-01

    Case of a patient is presented here 20 years after spiral direct anastomosis of the great arteries in an arterial switch operation. Three-dimensional model of the heart combined with four-dimensional flow magnetic resonance imaging presents a novel comprehensive way to assess surgical results.

  6. Evaluation of Electrocardiographic Changes after Arterial Switch Operation

    Directory of Open Access Journals (Sweden)

    Hamid Amoozgar

    2014-09-01

    Full Text Available Background: Transposition of Great Arteries (TGA is a serious congenital heart disease which can be accompanied by good outcomes with anatomic correction within the first few weeks of life. Objectives: The present study aimed to evaluate electrocardiographic changes in the children with uncomplicated Arterial Switch Operation (ASO. Patients and Methods: Twelve lead electrocardiograms were obtained from thirty-three patients with TGA after ASO. Then, the patients’ QT-dispersion and P-wave dispersion were compared to those of 33 age- and gender-matched individuals as the normal control group. Both groups were also evaluated by M-mode echocardiography. Student’s t-test and Pearson correlation were used to analyze the data. Besides, P < 0.05 was considered as statistically significant. Results: The mean age of the patients and the control group was 41 ± 3.7 and 40.12 ± 4.2 months, respectively. Comparison of P wave, T wave, QRS complex, PR interval, QT segment, and corrected QT segment showed significant differences in the frequency of inverted T wave in pericardial leads [V3, V4, V5, and V6] (P = 0.004; more in patients, P wave amplitude in lead II (P < 0.001; more in patients, R wave amplitude in V1 (P = 0.016; smaller in patients, R and S waves amplitude in V6 (P = 0.004 and P = 0.001; taller in patients, corrected QT segment (in lead V5; P < 0.0001: prolonger in patients, and PR interval (P = 0.001; prolonger in patients. However, no significant differences were found regarding the vector axis and heart rate. Right bundle branch block (18% vs. 0%, Bifascicular (3% vs. 0%, and first-degree blocks (15% vs. 0% were significantly more in the patients. Besides, the PR interval was longer in the corrected complex TGA (146 ± 24.4 vs. 127.7 ± 23.1, P = 0.001. Moreover, R/S ratio in lead V1 was significantly prolonger, among the patients (2.86 ± 3.35 vs. 0.706 ± 0.53, P = 0.002. Nonetheless, no significant was observed between the patients and

  7. Interventional procedures of the isolated iliac arterial aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Ohm, Joon Young [The Catholic Univ. of Korea College of Medicine, Bucheon (Korea, Republic of); Shin, Byung Seok; Ahn, Moon Sang [Chungnam National Univ. Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dankook Univ. Hospital, Cheonan (Korea, Republic of); Kim, Ho Jun [Konyang Univ. Hospital, Daejeon (Korea, Republic of)

    2012-05-15

    To report the results of treatment isolated iliac arterial aneurysms by interventional procedures. Over a period of 5 years, 7 isolated iliac artery aneurysms (4 in the common iliac artery, 3 in the internal iliac artery) in 7 patients (3 women, 4 men; mean age, 65.7 years) were treated using interventional procedures. The mean aneurysm size was 35 mm (range, 30-45 mm). The common iliac aneurysms were treated using a unilateral stent graft (2 balloon expandable, 2 self expandable) with coil embolization of the internal iliac artery (n = 3), except for 1 aneurysm that ruptured. Coil embolization alone was performed for aneurysms involving only the internal iliac artery (n = 3). All patients were treated successfully, except for 1 with an initial remnant of type 2 endoleak. There were no perioperative complications. No leakage or complication occurred at the mean follow up of 14 months (range 2-29 months). One patient with a ruptured aneurysm died of multi organ failure during the follow up period. Three aneurysms had decreased in size on follow up CT. Interventional procedures with stent grafting and coil embolization are safe and effective treatments for isolated iliac artery aneurysms.

  8. Bilateral axillary artery aneurysms after Bentall procedure in Marfan syndrome.

    Science.gov (United States)

    Haruki, Takashi; Ito, Hiroshi; Sakata, Kensuke; Kobayashi, Yurio

    2015-11-01

    A man with Marfan syndrome underwent a Bentall procedure for annuloaortic ectasia and severe aortic regurgitation at 43 years of age. Twenty-eight years after the Bentall procedure, he developed bilateral axillary artery aneurysms (length × diameter: right: 80 × 39 mm; left: 103 × 45 mm). Aneurysmectomy and reconstruction of the axillary artery were performed using an artificial vascular graft. Histological examination revealed cystic medial necrosis. The postoperative course was uneventful, but long-term follow-up is necessary. © The Author(s) 2014.

  9. Ulnar artery: The Ulysses ultimate resort for coronary procedures

    Directory of Open Access Journals (Sweden)

    George Hahalis, MD, PhD

    2016-07-01

    Full Text Available Despite the increasing worldwide adoption of the transradial access site, the ulnar artery (UA only very infrequently serves as a primary option for coronary procedures. In contrast to the uncertainty surrounding previous reports regarding the feasibility and safety, recent data from larger registries and randomized trials provide more conclusive evidence that the transulnar route may be safely selected as an alternative arterial access approach. However, a default transulnar strategy appears time-consuming and is associated with higher crossover rates compared with the radial artery (RA. Once arterial access is obtained, the likelihood of a successful coronary procedure is high and similar between the two forearm arteries. The UA has similar flow-mediating vasodilating properties with and seems at least as vulnerable as the RA with regard to incident occlusion, with UA occlusion (UAO rates being probably higher than previously anticipated. A learning curve effect may not be apparent for crossover rates among experienced radialists, but increasing experience is associated with reduction in the fluoroscopy time, contrast volume and frequency of large hematoma formation. The UA may represents an important alternative access site for coronary procedures, and experienced radial operators should obtain additional skills to perform the transulnar approach. Nevertheless, in view of this method's lower feasibility compared to the RA, an initial ulnar access strategy should be reserved for carefully selected patients to ensure satisfactory cannulation rates.

  10. Ulnar artery: The Ulysses ultimate resort for coronary procedures.

    Science.gov (United States)

    Hahalis, George; Deftereos, Spyridon; Bertrand, Olivier F

    2016-08-20

    Despite the increasing worldwide adoption of the transradial access site, the ulnar artery (UA) only very infrequently serves as a primary option for coronary procedures. In contrast to the uncertainty surrounding previous reports regarding the feasibility and safety, recent data from larger registries and randomized trials provide more conclusive evidence that the transulnar route may be safely selected as an alternative arterial access approach. However, a default transulnar strategy appears time-consuming and is associated with higher crossover rates compared with the radial artery (RA). Once arterial access is obtained, the likelihood of a successful coronary procedure is high and similar between the two forearm arteries. The UA has similar flow-mediating vasodilating properties with and seems at least as vulnerable as the RA with regard to incident occlusion, with UA occlusion (UAO) rates being probably higher than previously anticipated. A learning curve effect may not be apparent for crossover rates among experienced radialists, but increasing experience is associated with reduction in the fluoroscopy time, contrast volume and frequency of large hematoma formation. The UA may represents an important alternative access site for coronary procedures, and experienced radial operators should obtain additional skills to perform the transulnar approach. Nevertheless, in view of this method's lower feasibility compared to the RA, an initial ulnar access strategy should be reserved for carefully selected patients to ensure satisfactory cannulation rates. Copyright © 2016 Hellenic Cardiological Society. Published by Elsevier B.V. All rights reserved.

  11. Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants. Comparison with transthoracic echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of)

    2018-02-15

    Considering inherent limitations of transthoracic echocardiography, the diagnostic accuracy of cardiac CT in identifying coronary artery anatomy before arterial switch operation needs to be investigated with recently improved coronary artery visibility using electrocardiogram (ECG)-synchronized dual-source CT. To compare diagnostic accuracy between cardiac CT using a dual-source scanner and transthoracic echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. The study included 101 infants (median age 4 days, range 0 days to 10 months; M:F=78:23) who underwent ECG-synchronized cardiac dual-source CT and transthoracic echocardiography before arterial switch operation between July 2011 and December 2016. We evaluated and classified coronary artery anatomy on cardiac CT and transthoracic echocardiography. With the surgical findings as the reference standard, we compared the diagnostic accuracy for identifying coronary artery anatomy between cardiac CT and transthoracic echocardiography. The most common coronary artery pattern was the usual pattern (left coronary artery from sinus 1 and right coronary artery from sinus 2; 64.4%, 65/101), followed by a single coronary artery from sinus 2 and a conal branch from sinus 1 (7.9%, 8/101), the inverted pattern (5.9%, 6/101), the right coronary artery and left anterior descending artery from sinus 1 and the left circumflex artery from sinus 2 (5.9%, 6/101), and others. In 96 infants with surgically proven coronary artery anatomy, the diagnostic accuracy of cardiac CT was significantly higher than that of transthoracic echocardiography (91.7%, 88/96 vs. 54.2%, 52/96; P<0.0001). Diagnostic accuracy of cardiac CT is significantly higher than that of echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. (orig.)

  12. Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants. Comparison with transthoracic echocardiography

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2018-01-01

    Considering inherent limitations of transthoracic echocardiography, the diagnostic accuracy of cardiac CT in identifying coronary artery anatomy before arterial switch operation needs to be investigated with recently improved coronary artery visibility using electrocardiogram (ECG)-synchronized dual-source CT. To compare diagnostic accuracy between cardiac CT using a dual-source scanner and transthoracic echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. The study included 101 infants (median age 4 days, range 0 days to 10 months; M:F=78:23) who underwent ECG-synchronized cardiac dual-source CT and transthoracic echocardiography before arterial switch operation between July 2011 and December 2016. We evaluated and classified coronary artery anatomy on cardiac CT and transthoracic echocardiography. With the surgical findings as the reference standard, we compared the diagnostic accuracy for identifying coronary artery anatomy between cardiac CT and transthoracic echocardiography. The most common coronary artery pattern was the usual pattern (left coronary artery from sinus 1 and right coronary artery from sinus 2; 64.4%, 65/101), followed by a single coronary artery from sinus 2 and a conal branch from sinus 1 (7.9%, 8/101), the inverted pattern (5.9%, 6/101), the right coronary artery and left anterior descending artery from sinus 1 and the left circumflex artery from sinus 2 (5.9%, 6/101), and others. In 96 infants with surgically proven coronary artery anatomy, the diagnostic accuracy of cardiac CT was significantly higher than that of transthoracic echocardiography (91.7%, 88/96 vs. 54.2%, 52/96; P<0.0001). Diagnostic accuracy of cardiac CT is significantly higher than that of echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. (orig.)

  13. Aberrant hepatic arterial anatomy and the whipple procedure: lessons learned.

    Science.gov (United States)

    Chamberlain, Ronald S; El-Sedfy, Abraham; Rajkumar, Dhiraj

    2011-05-01

    Appreciation and study of hepatic arterial anatomical variability is essential to the performance of a pancreaticoduodenectomy to avoid surgical complications such as bleeding, hepatic ischemia/failure, and anastomotic leak/stricture. Awareness of this variability permits the surgeon to adapt the surgical technique to deal with anomalies identified preoperatively or intraoperatively thereby preventing unnecessary surgical morbidity and mortality. The objective of our study is to provide a comprehensive review of the anatomic arterial anomalies and discuss surgical strategies that will equip the surgeon to deal with all anomalies that may be encountered a priori or en passant during the course of a Whipple procedure.

  14. Managing Inadvertent Arterial Catheterization During Central Venous Access Procedures

    International Nuclear Information System (INIS)

    Nicholson, Tony; Ettles, Duncan; Robinson, Graham

    2004-01-01

    Purpose: Approximately 200,000 central venous catheterizations are carried out annually in the National Health Service in the United Kingdom. Inadvertent arterial puncture occurs in up to 3.7%. Significant morbidity and death has been reported. We report on our experience in the endovascular treatment of this iatrogenic complication. Methods: Retrospective analysis was carried out of 9 cases referred for endovascular treatment of inadvertent arterial puncture during central venous catheterization over a 5 year period. Results: It was not possible to obtain accurate figures on the numbers of central venous catheterizations carried out during the time period. Five patients were referred with carotid or subclavian pseudoaneurysms and hemothorax following inadvertent arterial catheter insertion and subsequent removal. These patients all underwent percutaneous balloon tamponade and/or stent-graft insertion. More recently 4 patients were referred with the catheter still in situ and were successfully treated with a percutaneous closure device. Conclusion: If inadvertent arterial catheterization during central venous access procedures is recognized and catheters removed, sequelae can be treated percutaneously. However, once the complication is recognized it is better to leave the catheter in situ and seal the artery percutaneously with a closure device

  15. Development of quality metrics for ambulatory pediatric cardiology: Transposition of the great arteries after arterial switch operation.

    Science.gov (United States)

    Baker-Smith, Carissa M; Carlson, Karina; Ettedgui, Jose; Tsuda, Takeshi; Jayakumar, K Anitha; Park, Matthew; Tede, Nikola; Uzark, Karen; Fleishman, Craig; Connuck, David; Likes, Maggie; Penny, Daniel J

    2018-01-01

    To develop quality metrics (QMs) for the ambulatory care of patients with transposition of the great arteries following arterial switch operation (TGA/ASO). Under the auspices of the American College of Cardiology Adult Congenital and Pediatric Cardiology (ACPC) Steering committee, the TGA/ASO team generated candidate QMs related to TGA/ASO ambulatory care. Candidate QMs were submitted to the ACPC Steering Committee and were reviewed for validity and feasibility using individual expert panel member scoring according to the RAND-UCLA methodology. QMs were then made available for review by the entire ACC ACPC during an "open comment period." Final approval of each QM was provided by a vote of the ACC ACPC Council. Patients with TGA who had undergone an ASO were included. Patients with complex transposition were excluded. Twelve candidate QMs were generated. Seven metrics passed the RAND-UCLA process. Four passed the "open comment period" and were ultimately approved by the Council. These included: (1) at least 1 echocardiogram performed during the first year of life reporting on the function, aortic dimension, degree of neoaortic valve insufficiency, the patency of the systemic and pulmonary outflows, the patency of the branch pulmonary arteries and coronary arteries, (2) neurodevelopmental (ND) assessment after ASO; (3) lipid profile by age 11 years; and (4) documentation of a transition of care plan to an adult congenital heart disease (CHD) provider by 18 years of age. Application of the RAND-UCLA methodology and linkage of this methodology to the ACPC approval process led to successful generation of 4 QMs relevant to the care of TGA/ASO pediatric patients in the ambulatory setting. These metrics have now been incorporated into the ACPC Quality Network providing guidance for the care of TGA/ASO patients across 30 CHD centers. © 2017 Wiley Periodicals, Inc.

  16. Anatomical study of forearm arteries with ultrasound for percutaneous coronary procedures.

    Science.gov (United States)

    Yan, Zhen-xian; Zhou, Yu-jie; Zhao, Ying-xin; Zhou, Zhi-ming; Yang, Shi-wei; Wang, Zhi-jian

    2010-04-01

    In recent years, the radial artery (RA) has become an alternative vascular access site for percutaneous coronary procedures, and the ulnar artery (UA) is another possibility. The objective of this study was to investigate the anatomy of the forearm arteries with ultrasound (US) and to evaluate the effect of the anatomy of the right RA (RRA) on the outcomes of transradial coronary procedures. The 638 patients undergoing transradial coronary procedures were examined with US for measurement of the diameters of the forearm arteries and determination of their anatomical abnormalities before the procedures. The next day the incidence of RA occlusion was recorded. The diameters of the radial and ulnar arteries were similar (P>0.05). The procedure time was longer in patients with anatomical abnormalities (Pforearm arteries of Chinese people are similar. The small diameter and anatomical abnormalities of the RRA could result in longer procedure time, more incidence of procedure failure and RA occlusion.

  17. Nuclear cardiology procedures to diagnose ischemia in coronary artery disease

    International Nuclear Information System (INIS)

    Kropp, J.

    1999-01-01

    Nuclear cardiology is equipped with a broad spectrum of diagnostic capabilities which allow the evaluation of ventricular performance, perfusion and metabolism of the heart. The principle of nuclear medicine procedures consists in the administration of free radioisotopes or radiopharmaceuticals to detect their spatial distribution within the body by detecting their y-rays from outside by gamma cameras. Myocardial perfusion scintigraphy is the most important procedure in nuclear cardiology and is performed on a routine basis with 201 Thallium-Chloride ( 201 Tl) since 1975. With the Single-Photon Emission Computerized Tomography (SPECT) technique it is possible to diagnose ischemia of the left ventricle on the basis of coronary artery disease with a sensitivity of 90-95% and a specificity of about 55%. Recently 99m Tc-tracers were developed for this purpose, which have many advantages due to their better physical properties, their easy handling and availability. The diagnostic accuracy is the same compared to ( 201 Tl). Free fatty acids labeled with 123 Iodine like 123 IPPA are alternative tracers to diagnose ischemia by the metabolic alteration and are pathognomonic tracers to diagnose the heart involvement in myopathies or metabolic defects related to fatty acid degradation which are the main fuel of the normal myocytes. Finally we should not forget the radionuclide ventriculography (RNVG) which is one of the oldest nuclear cardiology procedures providing us with very objective, reliable results of ventricular performance. (orig.)

  18. Canal switch after canalith repositioning procedure for benign paroxysmal positional vertigo.

    Science.gov (United States)

    Lin, Giant C; Basura, Gregory J; Wong, Hiu Tung; Heidenreich, Katherine D

    2012-09-01

    Canal switch is a complication following canalith repositioning procedure (CRP) for posterior canal benign paroxysmal positional vertigo (BPPV). Instead of being returned to the utricle, the loose otoconia migrate into the superior or horizontal semicircular canal. Patients remain symptomatic, and treatment can be ineffective unless the switch is recognized and additional repositioning maneuvers directed toward the appropriate semicircular canal are performed. This report provides the first videographic documentation of canal switch involving conversion of unilateral posterior semicircular canal BPPV to geotropic horizontal canalithiasis. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  19. In vitro evaluation of physiological spiral anastomoses for the arterial switch operation in simple transposition of the great arteries: a first step towards a surgical alternative?

    Science.gov (United States)

    Sievers, Hans-Hinrich; Scharfschwerdt, Michael; Putman, Léon M

    2015-08-01

    The currently most frequently used technique for the arterial switch operation (ASO) in simple transposition of the great arteries (TGA) includes the transposition of the pulmonary artery anterior to the ascending aorta. This arterial arrangement is less anatomical, and although the initial results are excellent, some long-term data are indicating a certain risk of morbidity, encouraging the search for more physiological techniques. As a first step, we studied the feasibility of anatomical spiral anastomoses of the great vessels in vitro. A TGA model was constructed to simulate the different spatial positions of the great arteries followed by ASO with physiological spiral connections of the great arteries. It was possible to perform a physiological spiral connection of the great arteries without tension or torsion when the roots of the great vessels were arranged anterior-posterior and with up to 35° rotation of the aortic root to the right around the pulmonary root. With further rotation of the aorta, patch plasties were required for pulmonary artery elongation. The maximal width of the patch was 5 mm. In this TGA model, it was possible to perform tension- and torsion-free arterial anastomoses for ASO without artificial material, when the aortic root was positioned from 0° up to 35° to the right of the pulmonary root. Evaluation of coronary transfer is the next step. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Evaluation of commissural malalignment of aortic-pulmonary sinus using cardiac CT for arterial switch operation: comparison with transthoracic echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Ji Hyun; Park, Jeong-Jun [Asan Medical Center, University of Ulsan College of Medicine, Divisions of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Goo, Hyun Woo [Asan Medical Center, University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of)

    2017-05-15

    There are limited data regarding the influence of commissural malalignment of the aortic-pulmonary sinus on the arterial switch operation. To compare diagnostic accuracy between cardiac CT and echocardiography for evaluating commissural malalignment of aortic-pulmonary sinus in children with complete transposition of the great arteries and to seek potential clinical implication of commissural malalignment on the arterial switch operation. In 37 patients (35 boys; median age: 8 days, range: 3-80 days) with complete transposition of the great arteries who had tricuspid semilunar valves and underwent an arterial switch operation, the degree of the commissural rotation of the aortic-pulmonary sinus was assessed on cardiac CT (n=37) and echocardiography (n=35). With surgical finding as a reference, cardiac CT was compared with echocardiography in identifying commissural malalignment in 35 patients. The influence of the height difference between the semilunar valves measured by cardiac CT on the identification of commissural malalignment with cardiac CT and echocardiography was evaluated. The impact of commissural malalignment on coronary transfer techniques was evaluated. In operative findings, the commissures of the semilunar valves were aligned in 24 patients and malaligned in 13. With surgical findings as a reference, cardiac CT showed higher, but not statistically significant (P>0.05), sensitivity (91.7% vs. 75.0%), specificity (87.0% vs. 78.3%) and accuracy (88.6% vs. 77.1%) for the diagnosis of the malalignment than echocardiography. The measured height difference between the semilunar valves did not affect the identification of the malalignment with cardiac CT and echocardiography. The surgical malalignment group showed a higher requirement of modified coronary transfer techniques than the surgical aligned group (11/13 vs. 11/24, P=0.03). Cardiac CT and echocardiography appear useful for evaluating commissural malalignment of the semilunar valves in patients with

  1. Evaluation of commissural malalignment of aortic-pulmonary sinus using cardiac CT for arterial switch operation: comparison with transthoracic echocardiography

    International Nuclear Information System (INIS)

    Bang, Ji Hyun; Park, Jeong-Jun; Goo, Hyun Woo

    2017-01-01

    There are limited data regarding the influence of commissural malalignment of the aortic-pulmonary sinus on the arterial switch operation. To compare diagnostic accuracy between cardiac CT and echocardiography for evaluating commissural malalignment of aortic-pulmonary sinus in children with complete transposition of the great arteries and to seek potential clinical implication of commissural malalignment on the arterial switch operation. In 37 patients (35 boys; median age: 8 days, range: 3-80 days) with complete transposition of the great arteries who had tricuspid semilunar valves and underwent an arterial switch operation, the degree of the commissural rotation of the aortic-pulmonary sinus was assessed on cardiac CT (n=37) and echocardiography (n=35). With surgical finding as a reference, cardiac CT was compared with echocardiography in identifying commissural malalignment in 35 patients. The influence of the height difference between the semilunar valves measured by cardiac CT on the identification of commissural malalignment with cardiac CT and echocardiography was evaluated. The impact of commissural malalignment on coronary transfer techniques was evaluated. In operative findings, the commissures of the semilunar valves were aligned in 24 patients and malaligned in 13. With surgical findings as a reference, cardiac CT showed higher, but not statistically significant (P>0.05), sensitivity (91.7% vs. 75.0%), specificity (87.0% vs. 78.3%) and accuracy (88.6% vs. 77.1%) for the diagnosis of the malalignment than echocardiography. The measured height difference between the semilunar valves did not affect the identification of the malalignment with cardiac CT and echocardiography. The surgical malalignment group showed a higher requirement of modified coronary transfer techniques than the surgical aligned group (11/13 vs. 11/24, P=0.03). Cardiac CT and echocardiography appear useful for evaluating commissural malalignment of the semilunar valves in patients with

  2. Clinical use of femoral artery hemostasis sticking after interventional procedure via femoral artery access

    International Nuclear Information System (INIS)

    Zhu Zhongsheng; Chen Shaoliang; Ye Fei; Zhang Junjie; Zhou Jie; Tian Nailiang; Lin Song; Liu Zhizhong; Xiao Pingxi; Qu Hong

    2010-01-01

    Objective: To observe the clinical effect of the use of femoral artery hemostasis sticking V+PAD after the interventional procedure via femoral artery access. Methods: By using random permutation list 80 patients, who decided to receive coronary angiography and percutaneous transluminal coronary angioplasty, were randomly selected. Of the 80 patients, hemostasis sticking V + PAD was employed in 40 patients with even numbers (trial group), only manual compression was adopted to stop bleeding in another 40 patients with odd numbers (control group). All the patients were informed about this trial and had to sign a consent letter. The pressure time, the treatment method of access site after hemostasis, the posture in bed, the immobilization time, the comfort degree of patients, the complications of access site prior to discharge, etc. were observed and the results were compared between two groups. Results: There was no significant difference between two groups as respect to age, gender ratios,activated clotting time (ACT) value and blood pressure. However, significantly difference in the compression time and bed rest time existed between the two groups. The compression time in trial group and control group was (7.9 ± 0.5) min and (19.8 ± 5.1) min respectively (P<0.01), while the bed rest time in trial group and control group was (6.1 ± 5.0) hours and (23.9 ± 0.2) hours respectively (P<0.01). All patients in trial group was supine in bed with the head side of the bed raised at 30 degree immediately after the procedure, and the head side of the bed was further raised to 90 degree one hour later. The puncture site was bandaged with conventional compression and immobilization was not employed. Patients could lie in bed with free posture and the patient's comfort degree was greatly improved. During hospitalization no complications related to puncture site occurred in all patients except one obese woman in trial group who developed pseudoaneurysm. Conclusion: Femoral

  3. Initial use of fast switched dual energy CT for coronary artery disease

    Science.gov (United States)

    Pavlicek, William; Panse, Prasad; Hara, Amy; Boltz, Thomas; Paden, Robert; Yamak, Didem; Licato, Paul; Chandra, Naveen; Okerlund, Darin; Dutta, Sandeep; Bhotika, Rahul; Langan, David

    2010-04-01

    Coronary CT Angiography (CTA) is limited in patients with calcified plaque and stents. CTA is unable to confidently differentiate fibrous from lipid plaque. Fast switched dual energy CTA offers certain advantages. Dual energy CTA removes calcium thereby improving visualization of the lumen and potentially providing a more accurate measure of stenosis. Dual energy CTA directly measures calcium burden (calcium hydroxyapatite) thereby eliminating a separate non-contrast series for Agatston Scoring. Using material basis pairs, the differentiation of fibrous and lipid plaques is also possible. Patency of a previously stented coronary artery is difficult to visualize with CTA due to resolution constraints and localized beam hardening artifacts. Monochromatic 70 keV or Iodine images coupled with Virtual Non-stent images lessen beam hardening artifact and blooming. Virtual removal of stainless steel stents improves assessment of in-stent re-stenosis. A beating heart phantom with 'cholesterol' and 'fibrous' phantom coronary plaques were imaged with dual energy CTA. Statistical classification methods (SVM, kNN, and LDA) distinguished 'cholesterol' from 'fibrous' phantom plaque tissue. Applying this classification method to 16 human soft plaques, a lipid 'burden' may be useful for characterizing risk of coronary disease. We also found that dual energy CTA is more sensitive to iodine contrast than conventional CTA which could improve the differentiation of myocardial infarct and ischemia on delayed acquisitions. These phantom and patient acquisitions show advantages with using fast switched dual energy CTA for coronary imaging and potentially extends the use of CT for addressing problem areas of non-invasive evaluation of coronary artery disease.

  4. [Primary, single-stage arterial switch operations at a newly-established, comprehensive congenital cardiac center performed in the neonatal age and beyond].

    Science.gov (United States)

    Király, László; Tamás, Csaba

    2015-06-21

    Outcome of arterial switch operation for transposition of the great arteries with/without ventricular septal defect is a service key-performance-indicator. The aim of the authors was to assess patient characteristics and parameters in the perioperative course. In the setting of a newly-established, comprehensive tertiary-care center, primary complete repair was performed including associated anomalies, e.g. transverse arch repairs. Patients with d-transposition were grouped according to coexistence of ventricular septal defect. 118 arterial switch operations were performed between 2007 and 2014 with 96.62% survival (114/118). Ventricular septal defect and repair of associated anomalies did not yield worse outcome. Left ventricular re-training with late presentation necessitated mechanical circulatory support for 4.5±1.5 days. D-transposition is suitable for standardization of clinical algorithm and surgical technique. Quality standards contribute to excellent outcomes, minimize complications, and serve as blueprint for other neonatal open-heart procedures. Availability of mechanical circulatory support is key for single-stage left ventricular re-training beyond the neonatal period.

  5. Early outcome for the primary arterial switch operation beyond the age of 3 weeks.

    Science.gov (United States)

    Ismail, Sameh R; Kabbani, Mohamed S; Najm, Hani K; Abusuliman, Riyadh M; Elbarbary, Mahmoud

    2010-07-01

    The arterial switch operation (ASO) for neonates is the standard management for transposition of the great arteries (TGA) with an intact ventricular septum (IVS). Patients presenting for late ASO are at risk due to the possibility of left ventricle (LV) involution. This study aimed to assess the early postoperative course and outcome for children with TGA/IVS and still conditioned LV presenting for late primary ASO. A retrospective study of all TGA/IVS patients who underwent a primary ASO between March 2002 and March 2008 was conducted. The cases were divided into two groups. Group A included all the cases of early ASO repaired before the age of 3 weeks, whereas group B included all the preslected cases of late ASO repaired after the age of 3 weeks. The demographics, intensive care unit (ICU) parameters, complications, and short-term outcomes of the two groups were compared. The study enrolled of 91 patients: 64 patients (70%) in group A and 27 patients (30%) in group B. The mean age was 11 +/- 4 days in group A and 37 +/- 17 days in group B (P age should not be a limitation for ASO.

  6. Is there an anatomic basis for subvalvular right ventricular outflow tract obstruction after an arterial switch repair for complete transposition? A morphometric study and review

    NARCIS (Netherlands)

    Akiba, T.; Neirotti, R.; Becker, A. E.

    1993-01-01

    The study was initiated by reports on right ventricular outflow tract obstruction in complete transposition of the great arteries after an arterial switch repair. We investigated 39 heart specimens with native, unoperated transposition of the great arteries. Of these, 14 hearts had a ventricular

  7. Blood Pressure Control in Smokers with Arterial Hypertension Who Switched to Electronic Cigarettes

    Directory of Open Access Journals (Sweden)

    Riccardo Polosa

    2016-11-01

    Full Text Available Electronic cigarettes (ECs are battery-operated devices designed to vaporise nicotine, which may help smokers with quitting or reducing their tobacco consumption. No data is available regarding the health effects of ECs use among smokers with arterial hypertension and whether regular use results in blood pressure (BP changes. We investigated long-term changes in resting BP and level of BP control in hypertensive smokers who quit or reduced substantially their tobacco consumption by switching to ECs. A medical records review of patients with hypertension was conducted to identify patients reporting regular daily use of ECs on at least two consecutive follow-up visits. Regularly smoking hypertensive patients were included as a reference group. A marked reduction in cigarette consumption was observed in ECs users (n = 43 though consumption remained unchanged in the control group (n = 46. Compared to baseline, at 12 months (follow-up visit 2 decline in cigarette consumption was associated with significant reductions in median (25th-, 75th-centile systolic BP (140 (134.5, 144 to 130 (123.5, 138.5 mmHg; p < 0.001 and diastolic BP (86 (78, 90 to 80 (74.5, 90 mmHg; p = 0.006. No significant changes were observed in the control group. As expected, decline in cigarette consumption in the ECs users was also associated with improved BP control. The study concludes that regular ECs use may aid smokers with arterial hypertension reduce or abstain from cigarette smoking, with only trivial post-cessation weight gain. This resulted in improvements in systolic and diastolic BP as well as better BP control.

  8. Resection-Reconstruction of Aberrant Right Hepatic Artery During Whipple Procedure (Pancreaticoduodenectomy).

    Science.gov (United States)

    Sayyed, Raza; Rehman, Iffat; Niazi, Imran Khalid; Yusuf, Muhammed Aasim; Syed, Aamir Ali; V, Faisal

    2016-06-01

    Aberrant hepatic arterial anatomy poses a challenge for the surgeon during Whipple procedure. Intraoperative injury to the aberrant vasculature results in hemorrhagic or ischemic complications involving the liver and biliary tree. We report a case of replaced right hepatic artery arising from the superior mesenteric artery in a patient with periampullary carcinoma of the pancreas, undergoing pancreaticoduodenectomy. The aberrant artery was found to be coursing through the pancreatic parenchyma. This is a rare vascular anomaly. Resection of the arterial segment and end-to-end anastomosis was fashioned. Intrapancreatic course of the replaced right hepatic artery is a rare anomaly and is best managed by preoperative identification on radiology and meticulous intra-operative dissection and preservation. However, for an intrapancreatic course, resection and reconstruction may occasionally be required.

  9. Evaluation of Cardiac and Valvular Function after Arterial Switch Operation: A Midterm Follow-Up

    Directory of Open Access Journals (Sweden)

    Hamid Amoozgar

    2013-09-01

    Full Text Available Objectives: Transposition of Great Arteries (TGA is a serious congenital heart disease and anatomic correction in the first few weeks of life has revealed good outcomes nowadays. In this study, we aimed to evaluate the myocardial and valvular function at midterm postoperative follow-up. Patients and Methods: In this study, thirty-three patients with TGA and Arterial Switch Operation (ASO were evaluated by 2-dimensional, M-mode, Doppler, and pulsed Tissue Doppler. These patients were compared with 33 healthy children of the same age and gender as the normal control group. Student’s t-test and Pearson correlation were used to analyze the data. Besides, P<0.05 was considered as statistically significant. Results: The mean follow up time was 40.9±5.6 months. Among the 33 patients with ASO, 6% had mild pulmonary stenosis, while 3% had mild pulmonary insufficiency. Aortic stenosis and aortic insufficiency of trivial to mild degree was seen in 12% and 12% of the patients, respectively. The patients’ systolic velocity of tricuspid (S, early diastolic velocity of tricuspid (Ea, and late velocity of tricuspid valve (Aa were significantly different from those of the controls (P<0.001. Also, pulmonary annulus diameter was significantly dilated in the patients compared to the controls (1.67±0.41 vs. 1.29±0.28, P≤0.001. Besides, aortic annulus diameter (1.56±0.42 vs. 1.24±0.21, P=0.001 and also aortic sinus diameter (2.06±0.41 vs. 1.44±0.34, P=0.002 were significantly dilated, while sinutuboar junction diameter (1.65±0.5 vs. 1.28±0.29, P=0.094 was not dilated. Left ventricular function was in the normal range. Conclusions: This study showed good left ventricular function, but some abnormalities in lateral tricuspid tissue Doppler velocities. Neoaortic and pulmonary diameters were significantly dilated, while aortic and pulmonary insufficiencies were clinically insignificant in most of the patients. Long-term follow-up is necessary in these

  10. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken [Shakaihoken Chukyo Hospital, Nagoya (Japan)] [and others

    2000-05-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6{+-}14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3{+-}9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280{+-}0.0068 vs ASO group 0.0219{+-}0.0083), and gradually increased with time (1-3 years: 0.0470{+-}0.0157 vs 0.0314{+-}0.0124). (author)

  11. The effect of vasodilatory medications on radial artery spasm in patients undergoing transradial coronary artery procedures: a systematic review.

    Science.gov (United States)

    Curtis, Elizabeth; Fernandez, Ritin; Lee, Astin

    2017-07-01

    The uptake of percutaneous coronary procedures via the radial artery has increased internationally due to the decreased risk of complications and increased patient satisfaction. The increased susceptibility of the radial artery to spasm however presents a potential risk for procedural failure. Although most experts agree on the need for prophylactic medications to reduce radial artery spasm, currently there is inconsistency in literature regarding the most effective vasodilatory medication or combination of medications. The objective of this study is to identify the effectiveness of vasodilatory medications on radial artery spasm in patients undergoing transradial coronary artery procedures. This review considered studies that included participants aged 18 years and over undergoing non-emergent transradial percutaneous coronary artery procedures. This review considered studies that used vasodilating intravenous and intra-arterial medications or combinations of medications prior to commencing and during transradial coronary approaches to reduce radial artery spasm. The outcomes of interest were the incidence of radial artery spasm during percutaneous coronary procedure using objective and/or subjective measures and its effect on the successful completion of the procedure. Randomized controlled trials published in the English language between 1989 to date were considered for inclusion. The search strategy aimed to find both published and unpublished studies. A three-step search strategy was utilized in this review. An initial search of MEDLINE, CINAHL and Scopus was undertaken, followed by a search for unpublished studies. Papers selected for retrieval were assessed by two independent reviewers for methodological validity prior to inclusion in the review using standardized critical appraisal instruments. Any disagreements that arose between the reviewers were resolved through discussion. Quantitative data was extracted from papers included in the review using the

  12. Cost analysis of procedures related to the management of renal artery stenosis from various perspectives

    International Nuclear Information System (INIS)

    Helvoort-Postulart, Debby van; Dirksen, Carmen D.; Kessels, Alfons G.H.; Kroon, Abraham A.; Leeuw, Peter W. de; Nelemans, Patricia J.; Engelshoven, Jos M.A. van; Myriam Hunink, M.G.

    2006-01-01

    To determine the costs associated with the diagnostic work-up and percutaneous revascularization of renal artery stenosis from various perspectives. A prospective multicenter comparative study was conducted between 1998 and 2001. A total of 402 hypertensive patients with suspected renal artery stenosis were included. Costs were assessed of computed tomography angiography (CTA), magnetic resonance angiography (MRA), digital subtraction angiography (DSA), and percutaneous revascularization. From the societal perspective, DSA was the most costly (EUR 1,721) and CTA the least costly diagnostic technique (EUR 424). CTA was the least costly imaging procedure irrespective of the perspective used. The societal costs associated with percutaneous renal artery revascularization ranged from EUR 2,680 to EUR 6,172. Overall the radiology department incurred the largest proportion of the total societal costs. For the management of renal artery stenosis, performing the analysis from different perspectives leads to the same conclusion concerning the least costly diagnostic imaging and revascularization procedure. (orig.)

  13. Impact of standardized clinical assessment and management plans on resource utilization and costs in children after the arterial switch operation.

    Science.gov (United States)

    Rathod, Rahul H; Jurgen, Brittney; Hamershock, Rose A; Friedman, Kevin G; Marshall, Audrey C; Samnaliev, Mihail; Graham, Dionne A; Jenkins, Kathy; Lock, James E; Powell, Andrew J

    2017-12-01

    Standardized Clinical Assessment and Management Plans (SCAMPs) are a quality improvement initiative designed to reduce unnecessary utilization, decrease practice variation, and improve patient outcomes. We created a novel methodology, the SCAMP managed episode of care (SMEOC), which encompasses multiple encounters to assess the impact of the arterial switch operation (ASO) SCAMP on total costs. All ASO SCAMP patients (dates March 2009 to July 2015) were compared to a control group of ASO patients (January 2001 to February 2009). Patients were divided into "younger" (operation while maintaining quality of care. © 2017 Wiley Periodicals, Inc.

  14. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    International Nuclear Information System (INIS)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken

    2000-01-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6±14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3±9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280±0.0068 vs ASO group 0.0219±0.0083), and gradually increased with time (1-3 years: 0.0470±0.0157 vs 0.0314±0.0124). (author)

  15. Endovascular Procedures in Treatment of Infrapopliteal Arterial Occlusive Disease: Single Center Experience With 69 Infrapopliteal Procedures.

    Science.gov (United States)

    Janko, Pasternak J; Nebojsa, Budakov B; Andrej, Petres V

    2018-03-01

    Peripheral arterial occlusive disease (PAD) includes acute and chronic disorders of the blood supply as a result of obstruction of blood flow in the arteries of the limb. Treatment of PAD can be conservative, surgical and endovascular. Percutaneous transluminal angioplasty with or without stenting has become a recognized method, which is increasingly used in treatment of arterial occlusive disease. This study aimed to determine early results of endovascular treatment of critical limb ischemia (CLI) patients with infrapopliteal lesions. The study included 69 patients (46 men; mean age 65 years, range 38-84) with CLI (class 4 to 6 according to Rutherford). The primary study endpoints were absence of major amputation of the target limb at 6 months and occurance of local and systemic complications specifically related to use of endovascular treatment. Major amputation was avoided in 61 patients. Through 6 months, 6 patients underwent additional revascularization. One local complication (clinicaly significant dissection of popliteal artery) occurred, and it was resolved by stent implantation. There were no cases of systemic complications and death during the follow-up period. Rates of major amputation were 12.3% for diabetics versus 8.3% for non-diabetics. Our data showed that endovascular treatment of infrapopliteal disease is an effective and safe treatment in patients experiencing CLI, provides high limb preservation and low complication rates. Study outcomes support endovascular treatment as a primary option for patients experiencing CLI due to below the knee (BTK) occlusive disease. © 2018 The Author(s). This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  16. Examining Age-Related Differences in Auditory Attention Control Using a Task-Switching Procedure

    OpenAIRE

    Vera Lawo; Iring Koch

    2014-01-01

    Objectives. Using a novel task-switching variant of dichotic selective listening, we examined age-related differences in the ability to intentionally switch auditory attention between 2 speakers defined by their sex.

  17. A case of central retinal artery occlusion following embolization procedure for juvenile nasopharyngeal angiofibroma

    Science.gov (United States)

    Ramezani, Alireza; Haghighatkhah, Hamidreza; Moghadasi, Habibollah; Taheri, Morteza S; Parsafar, Hiva

    2010-01-01

    A 23-year-old male patient with right nasal Juvenile Nasopharyngeal Angiofibroma (JNA) developed Central Retinal Artery Occlusion (CRAO) during embolization of the tumor using polyvinyl alcohol particles before endoscopic excision. Classic CRAO management was initiated by an ophthalmologist after 12 h. Retrospective evaluation of the angiograms revealed a tiny communication between the external carotid and ophthalmic arteries which had not been noticed before embolization. During endoscopic excision, the tumor was found to originate extraordinarily from midline structures. It was concluded that CRAO might be a rare complication of JNA embolization. Careful preoperative angiographic evaluations to detect communicating arteries and immediate ophthalmologic consultation in case of developing visual symptoms during the procedure are necessary. PMID:20689199

  18. A case of central retinal artery occlusion following embolization procedure for juvenile nasopharyngeal angiofibroma

    Directory of Open Access Journals (Sweden)

    Ramezani Alireza

    2010-01-01

    Full Text Available A 23-year-old male patient with right nasal Juvenile Nasopharyngeal Angiofibroma (JNA developed Central Retinal Artery Occlusion (CRAO during embolization of the tumor using polyvinyl alcohol particles before endoscopic excision. Classic CRAO management was initiated by an ophthalmologist after 12 h. Retrospective evaluation of the angiograms revealed a tiny communication between the external carotid and ophthalmic arteries which had not been noticed before embolization. During endoscopic excision, the tumor was found to originate extraordinarily from midline structures. It was concluded that CRAO might be a rare complication of JNA embolization. Careful preoperative angiographic evaluations to detect communicating arteries and immediate ophthalmologic consultation in case of developing visual symptoms during the procedure are necessary.

  19. There is no benefit to universal carotid artery duplex screening before a major cardiac surgical procedure.

    Science.gov (United States)

    Adams, Brian C; Clark, Ross M; Paap, Christina; Goff, James M

    2014-01-01

    Perioperative stroke is a devastating complication after cardiac surgery. In an attempt to minimize this complication, many cardiac surgeons routinely preoperatively order carotid artery duplex scans to assess for significant carotid stenosis. We hypothesize that the routine screening of preoperative cardiac surgery patients with carotid artery duplex scans detects few patients who would benefit from carotid intervention or that a significant carotid stenosis reliably predicts stroke risk after cardiac surgery. A retrospective review identified 1,499 patients who underwent cardiac surgical procedures between July 1999 and September 2010. Data collected included patient demographics, comorbidities, history of previous stroke, preoperative carotid artery duplex scan results, location of postoperative stroke, and details of carotid endarterectomy (CEA) procedures before, in conjunction with, or after cardiac surgery. Statistical methods included univariate analysis and Fisher's exact test. Twenty-six perioperative strokes were identified (1.7%). In the 21 postoperative stroke patients for whom there is complete carotid artery duplex scan data, 3 patients had a hemodynamically significant lesion (>70%) and 1 patient underwent unilateral carotid CEA for bilateral disease. Postoperative strokes occurred in the anterior cerebral circulation (69.2%), posterior cerebral circulation (15.4%), or both (15.4%). Patient comorbidities, preoperative carotid artery duplex scan screening velocities, or types of cardiac surgical procedure were not predictive for stroke. Thirteen patients (0.86%) underwent CEA before, in conjunction with, or after cardiac surgery. Two of these patients had symptomatic disease, 1 of whom underwent CEA before and the other after his cardiac surgery. Of the 11 asymptomatic patients, 2 underwent CEA before, 3 concurrently, and 6 after cardiac surgery. Left main disease (≥50% stenosis), previous stroke, and peripheral vascular disease were found to be

  20. Hilar anatomy of the hepatic artery and surgical procedure for hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Uesaka, Katsuhiko; Maeda, Atsuyuki; Kanamoto, Hideyuki; Matsunaga, Kazuya; Yuasa, Ichiro; Okamura, Yukiyasu; Yamaguchi, Shigeki; Bando, Etsuro; Furukawa, Hiroyoshi

    2006-01-01

    This paper describes the examination of findings by multi-detector-row CT (MDCT) and by surgery to obtain the anatomy of hilar arteries and portal vein, which is necessary for the procedure in the title. Subjects are those findings of 38 patients with hilar cholangiocarcinoma, who underwent its excision during the period of 1 year from 2002 Nov. Before operation, MDCT with 16-row detector was done 20-120 sec after infusion of a non-ionized contrast medium to compose the 3D images. The left hepatic arterial system was found to be classifiable in 3 types of common, anti-clockwise and clockwise one with the respective frequency of 63, 24 and 11%, and the right system, infra-portal (76%) and supra-portal (24%) types. It was concluded that to the arterial clockwise and supra-portal types, particular attention should be paid for the cancer invasion there and for avoidance of the artery damage during the operation. (T.I.)

  1. Evaluation of knowledge-based reconstruction for magnetic resonance volumetry of the right ventricle after arterial switch operation for dextro-transposition of the great arteries.

    Science.gov (United States)

    Nyns, Emile C A; Dragulescu, Andreea; Yoo, Shi-Joon; Grosse-Wortmann, Lars

    2016-09-01

    Right ventricular (RV) volume and function evaluation is essential in the follow-up of patients after arterial switch operation (ASO) for dextro-transposition of the great arteries (d-TGA). Cardiac magnetic resonance (CMR) imaging using the Simpson's method is the gold-standard for measuring these parameters. However, this method can be challenging and time-consuming, especially in congenital heart disease. Knowledge-based reconstruction (KBR) is an alternative method to derive volumes from CMR datasets. It is based on the identification of a finite number of anatomical RV landmarks in various planes, followed by computer-based reconstruction of the endocardial contours by matching these landmarks with a reference library of representative RV shapes. The purpose of this study was to evaluate the feasibility, accuracy, reproducibility and labor intensity of KBR for RV volumetry in patients after ASO for d-TGA. The CMR datasets of 17 children and adolescents (males 11, median age 15) were studied for RV volumetry using both KBR and Simpson's method. The intraobserver, interobserver and intermethod variabilities were assessed using Bland-Altman analyses. Good correlation between KBR and Simpson's method was noted. Intraobserver and interobserver variability for KBR showed excellent agreement. Volume and function assessment using KBR was faster when compared with the Simpson's method (5.1 ± 0.6 vs. 6.7 ± 0.9 min, p < 0.001). KBR is a feasible, accurate, reproducible and fast method for measuring RV volumes and function derived from CMR in patients after ASO for d-TGA.

  2. Outcomes after corrective surgery for congenital dextro-transposition of the great arteries using the arterial switch technique: a protocol for a scoping systematic review

    Science.gov (United States)

    Mbuagbaw, Lawrence; Forlemu-Kamwa, Doris; Chu, Angela; Thabane, Lehana; Dillenberg, Rejane

    2014-01-01

    Introduction Dextro-transposition of the great arteries (d-TGA) is a life-threatening congenital health defect that requires rapid surgery. The most widely used approach is the arterial switch operation (ASO) developed by Jatene in the 1970s. The first set of children who received this intervention are now adults. The objective of this scoping review of the literature was to document the short-term (less than 1 year), medium-term (1–20 years) and long-term (more than 20 years) outcomes in children who underwent the ASO. Our primary income is survival, but we will explore other secondary surgical, cardiovascular, reproductive and quality-of-life outcomes. Methods and analyses Using a systematic scoping review approach, we will conduct a systematic search of the published literature for experimental and observational studies published on children who received the ASO intervention for classic d-TGA. We will search MEDLINE, Excerpta Medica Database (EMBASE), Cumulative Index to Nursing and Allied Health Literature (CINAHL) and Literatura Latino Americana em Ciências da Saúde (LILACS) from 1973 (date of the first successful ASO) to February 2014. Identified articles will be screened in duplicate and full text for selected articles will be retrieved. Data extraction will be carried out in duplicate. Discrepancies will be resolved by consensus or by consulting a third author. Where possible, proportions will be pooled using the inverse variance method. Our findings will be reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and Meta-analysis Of Observational studies in Epidemiology (MOOSE) guidelines. Ethics and dissemination The results of this paper will be disseminated as peer-reviewed publications, at conferences and at clinical rounds. Our findings may answer important questions for surgeons who perform the ASO intervention and for clinicians who take care of patients after surgery and throughout their

  3. Left Ventricular Function after Arterial Switch Operation as Assessed by Two-Dimensional Speckle-Tracking Echocardiography in Patients with Simple Transposition of the Great Arteries.

    Science.gov (United States)

    Malakan Rad, Elaheh; Ghandi, Yazdan; Kocharian, Armen; Mirzaaghayan, Mohammadreza

    2016-07-06

    Background: The late postoperative course for children with transposition of the great arteries (TGA) with an intact ventricular septum (IVS) is very important because the coronary arteries may be at risk of damage during arterial switch operation (ASO). We sought to investigate left ventricular function in patients with TGA/IVS by echocardiography. Methods: From March 2011 to December 2012, totally 20 infants (12 males and 8 females) with TGA/IVS were evaluated via 2-dimensional speckle-tracking echocardiography (2D STE) more than 6 months after they underwent ASO. A control group of age-matched infants and children was also studied. Left ventricular longitudinal strain (S), strain rate (SR), time to peak systolic longitudinal strain (TPS), and time to peak systolic longitudinal strain rate (TPSR) were measured and compared between the 2 groups. Results: Mean ± SD of age at the time of study in the patients with TGA/IVS was 15 ± 5 months, and also age at the time of ASO was 12 ± 3 days. Weight was 3.13 ± 0.07 kg at birth and 8.83 ± 1.57 kg at the time of ASO. Global strain (S), Time to peak strain rate (TPSR), and Time to peak strain (TPS) were not significantly different between the 2 groups, whereas global strain rate (SR) was significantly different (p value < 0.001). In the 3-chamber view, the values of S in the lateral, septal, inferior, and anteroseptal walls were significantly different between the 2 groups (p value < 0.001), and SR in the posterior wall was significantly different between the 2 groups (p value < 0.001). There were no positive correlations between S and SR in terms of the variables of heart rate, total cardiopulmonary bypass time, and aortic cross-clamp time. There were no statistically significant differences between the 2 groups regarding S, SR, TPS, and TPSR in the anteroseptal and posterior walls in the 3-chamber view and in the lateral and septal walls in the 4-chamber view. Conclusion: We showed that between 6 and 18 months after

  4. Examining age-related differences in auditory attention control using a task-switching procedure.

    Science.gov (United States)

    Lawo, Vera; Koch, Iring

    2014-03-01

    Using a novel task-switching variant of dichotic selective listening, we examined age-related differences in the ability to intentionally switch auditory attention between 2 speakers defined by their sex. In our task, young (M age = 23.2 years) and older adults (M age = 66.6 years) performed a numerical size categorization on spoken number words. The task-relevant speaker was indicated by a cue prior to auditory stimulus onset. The cuing interval was either short or long and varied randomly trial by trial. We found clear performance costs with instructed attention switches. These auditory attention switch costs decreased with prolonged cue-stimulus interval. Older adults were generally much slower (but not more error prone) than young adults, but switching-related effects did not differ across age groups. These data suggest that the ability to intentionally switch auditory attention in a selective listening task is not compromised in healthy aging. We discuss the role of modality-specific factors in age-related differences.

  5. Contribution of Nrf2 to Atherogenic Phenotype Switching of Coronary Arterial Smooth Muscle Cells Lacking CD38 Gene

    Directory of Open Access Journals (Sweden)

    Ming Xu

    2015-08-01

    Full Text Available Background/Aims: Recent studies have indicated that CD38 gene deficiency results in dedifferentiation or transdifferentiation of arterial smooth muscle cells upon atherogenic stimulations. However, the molecular mechanisms mediating this vascular smooth muscle (SMC phenotypic switching remain unknown. Methods & Results: In the present study, we first characterized the phenotypic change in the primary cultures of coronary arterial myocytes (CAMs from CD38-/- mice. It was shown that CD38 deficiency decreased the expression of contractile marker calponin, SM22α and α-SMA but increased the expression of SMC dedifferentiation marker, vimentin, which was accompanied by enhanced cell proliferation. This phenotypic change in CD38-/- CAMs was enhanced by 7-ketocholesterol (7-Ket, an atherogenic stimulus. We further found that the CD38 deficiency decreased the expression and activity of nuclear factor E2-related factor 2 (Nrf2, a basic leucine zipper (bZIP transcription factor sensitive to redox regulation. Similar to CD38 deletion, Nrf2 gene silencing increased CAM dedifferentiation upon 7-Ket stimulation. In contrast, the overexpression of Nrf2 gene abolished 7-Ket-induced dedifferentiation in CD38-/- CAMs. Given the sensitivity of Nrf2 to oxidative stress, we determined the role of redox signaling in the regulation of Nrf2 expression and activity associated with CD38 effect in CAM phenotype changes. It was demonstrated that in CD38-/- CAMs, 7-Ket failed to stimulate the production of O2-., while in CD38+/+ CAMs 7-Ket induced marked O2-. production and enhancement of Nrf2 activity, which was substantially attenuated by NOX4 gene silencing. Finally, we demonstrated that 7-Ket-induced and NOX4-dependent O2-. production was inhibited by 8-Br-cADPR, an antagonist of cADPR or NED-19, an antagonist of NAADP as product of CD38 ADP-ribosylcyclase, which significantly inhibited the level of cytosolic Ca2+ and the activation of Nrf2 under 7-Ket. Conclusion

  6. Gothic aortic arch and cardiac mechanics in young patients after arterial switch operation for d-transposition of the great arteries.

    Science.gov (United States)

    Di Salvo, Giovanni; Bulbul, Ziad; Pergola, Valeria; Issa, Ziad; Siblini, Ghassan; Muhanna, Nisreen; Galzerano, Domenico; Fadel, Bahaa; Al Joufan, Mansour; Al Fayyadh, Majid; Al Halees, Zohair

    2017-08-15

    In patients who have undergone arterial switch operation (ASO) for d-transposition of the great arteries a gothic aortic arch (GA) morphology has been found and it has been associated with abnormal aortic bio-elastic properties. GA is frequent in ASO patients and may have an impact on cardiac mechanics. Our study aims were to assess 1- the occurrence of GA in a large sample of patients after ASO; 2- the association between GA and aortic bio-elastic properties; and 3- the impact of GA on left ventricular (LV) function using speckle tracking echocardiography (STE). We studied one hundred and five asymptomatic patients, who have undergone first stage ASO for d-TGA, with normal left ventricular ejection fraction (LVEF ≥53%). Forty-six (44%) patients showed a GA (mean age 11.5±7.2years, 26 males) while fifty-nine (56%) patients (mean age 9.6±6.7years, 37 males) did not present GA. The two groups were comparable for age, sex, BSA, and office blood pressure values. In group GA aortic root was significantly dilated (27.4±7.5mm vs. 21.2±6.9mm, p<0.0001), aortic stiffness index (Group GA=1.8±1.2 vs. 1.4±0.7, p=0.025) was significantly increased, left atrial volume was larger (p=0.0145), global longitudinal strain (Group GA=-18.4±2.5% vs. -20.1±3.3%, p=0.012) and basal LV longitudinal strains (Group GA=-16.9±4.8% vs. -20.4±7.0%, p=0.013) were significantly reduced. After ASO the presence of a GA is associated with a significantly dilated aortic root, stiffer aortic wall, larger left atrial volume, and worse LV longitudinal systolic deformations, well known predictors of cardiovascular morbidity and mortality. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Exercise Performance in Patients with D-Loop Transposition of the Great Arteries After Arterial Switch Operation: Long-Term Outcomes and Longitudinal Assessment.

    Science.gov (United States)

    Kuebler, Joseph D; Chen, Ming-Hui; Alexander, Mark E; Rhodes, Jonathan

    2016-02-01

    The first patients to undergo a successful arterial switch operation (ASO) for d-transposition of the great arteries (D-TGA) are now entering their fourth decade of life. Past studies of ASO survivors' exercise function have yielded conflicting results. We therefore undertook this study to describe the current function of ASO survivors, to identify factors related to inferior exercise performance and to determine whether their exercise function tends to deteriorate over time. A retrospective cohort study was designed examining all patients with D-TGA after the ASO who underwent comprehensive cardiopulmonary exercise testing (CPET). Patients with palliative surgery prior to ASO, ventricular hypoplasia or severe valvar dysfunction were excluded from the study. Data from CPETs in which the peak respiratory exchange ratio was <1.09 were also excluded. We identified 113 patients who met entry criteria and had 186 CPX at our institution between 1/2002 and 1/2013; 41 patients had at least 2 qualifying CPX. Mean age at the time of the initial test was 17 ± 1 year. Peak oxygen consumption (VO2) averaged 84 ± 2 % predicted. Peak VO2 was lower among patients with repaired ventricular septal defects (82 ± 4 vs. 86 ± 3 % predicted; p < 0.05) and among patients with ≥ moderate right-sided obstructive lesions (77 ± 5 vs. 87 ± 3 % predicted; p < 0.05). Surgery prior to 1991 was also associated with a lower peak VO2 (81 ± 3 vs. 87 ± 3 % predicted; p < 0.01). The mean % predicted peak heart rate was 92 ± 1 %, with no significant difference between any of the subgroups. Non-diagnostic exercise-induced STT changes developed in 10 patients (12 studies). In the subgroup with at least 2 exercise tests, the annual decline in % predicted peak VO2 was quite slow (-0.3 % points/year; p < 0.01 vs. expected normal age-related decline). The exercise capacity of ASO survivors is well preserved and is only mildly reduced compared to normal subjects. Moreover, there is only a slight

  8. Virtual Whipple: preoperative surgical planning with volume-rendered MDCT images to identify arterial variants relevant to the Whipple procedure.

    Science.gov (United States)

    Brennan, Darren D; Zamboni, Giulia; Sosna, Jacob; Callery, Mark P; Vollmer, Charles M V; Raptopoulos, Vassilios D; Kruskal, Jonathan B

    2007-05-01

    The purposes of this study were to combine a thorough understanding of the technical aspects of the Whipple procedure with advanced rendering techniques by introducing a virtual Whipple procedure and to evaluate the utility of this new rendering technique in prediction of the arterial variants that cross the anticipated surgical resection plane. The virtual Whipple is a novel technique that follows the complex surgical steps in a Whipple procedure. Three-dimensional reconstructed angiographic images are used to identify arterial variants for the surgeon as part of the preoperative radiologic assessment of pancreatic and ampullary tumors.

  9. Safety and efficacy of rivaroxaban compared with warfarin in patients undergoing peripheral arterial procedures.

    Science.gov (United States)

    Talukdar, Anjan; Wang, S Keisin; Czosnowski, Lauren; Mokraoui, Nassim; Gupta, Alok; Fajardo, Andres; Dalsing, Michael; Motaganahalli, Raghu

    2017-10-01

    Rivaroxaban is a United States Food and Drug Administration-approved oral anticoagulant for venous thromboembolic disease; however, there is no information regarding the safety and its efficacy to support its use in patients after open or endovascular arterial interventions. We report the safety and efficacy of rivaroxaban vs warfarin in patients undergoing peripheral arterial interventions. This single-institution retrospective study analyzed all sequential patients from December 2012 to August 2014 (21 months) who were prescribed rivaroxaban or warfarin after a peripheral arterial procedure. Our study population was then compared using American College of Chest Physicians guidelines with patients then stratified as low, medium, or high risk for bleeding complications. Statistical analyses were performed using the Student t-test and χ 2 test to compare demographics, readmissions because of bleeding, and the need for secondary interventions. Logistic regression models were used for analysis of variables associated with bleeding complications and secondary interventions. The Fisher exact test was used for power analysis. There were 44 patients in the rivaroxaban group and 50 patients in the warfarin group. Differences between demographics and risk factors for bleeding between groups or reintervention rate were not statistically significant (P = .297). However, subgroup evaluation of the safety profile suggests that patients who were aged ≤65 years and on warfarin had an overall higher incidence of major bleeding (P = .020). Patients who were aged >65 years, undergoing open operation, had a significant risk for reintervention (P = .047) when they received rivaroxaban. Real-world experience using rivaroxaban and warfarin in patients after peripheral arterial procedures suggests a comparable safety and efficacy profile. Subgroup analysis of those requiring an open operation demonstrated a decreased bleeding risk when rivaroxaban was used (in those aged <65

  10. Arterial Injury Associated with Tension-Free Vaginal Tapes-SECUR Procedure Successfully Treated by Radiological Embolization

    Directory of Open Access Journals (Sweden)

    Yun Seok Jung

    2010-12-01

    Full Text Available Various postoperative complications have been reported after the use of tension-free vaginal tapes (TVT. The transobturator approach was introduced to minimize the potential complications. The next generation of recently introduced TVT-SECUR is intended to minimize the incidence of complications. Herein we report a case of internal pudendal artery injury sustained during this procedure that was successfully treated by radiological embolization. Angiography with vessel embolization, when available, should be considered when the arterial injury is suspected.

  11. Implication of the presence of a variant hepatic artery during the Whipple procedure.

    Science.gov (United States)

    Rubio-Manzanares-Dorado, Mercedes; Marín-Gómez, Luis Miguel; Aparicio-Sánchez, Daniel; Suárez-Artacho, Gonzalo; Bellido, Carmen; Álamo, José María; Serrano-Díaz-Canedo, Juan; Padillo-Ruiz, Francisco Javier; Gómez-Bravo, Miguel Ángel

    2015-07-01

    The anatomical variants of the hepatic artery may have important implications for pancreatic cancer surgery. The aim of our study is to compare the outcome following a pancreatoduodenectomy (PD) in patients with or without a variant hepatic artery arising from superior mesenteric artery. We reviewed 151 patients with periampullary tumoral pathology. All patients underwent oncological PD between January 2005 and February 2012. Our series was divided into two groups: Group A: Patients with a hepatic artery arising from superior mesenteric artery; and Group B: Patients without a hepatic artery arising from superior mesenteric artery. We expressed the results as mean +/- standard deviation for continuous variables and percentages for qualitative variables. Statistical tests were considered significant if p < 0.05. We identified 11 patients with a hepatic artery arising from superior mesenteric artery (7.3%). The most frequent variant was an aberrant right hepatic artery (n = 7), following by the accessory right hepatic artery (n = 2) and the common hepatic artery trunk arising from the superior mesenteric artery (n = 2). In 73% of cases the diagnosis of the variant was intraoperative. R0 resection was performed in all patients with a hepatic artery arising from superior mesenteric artery. There were no significant differences in the tumor resection margins and the incidence of postoperative complications. Oncological PD is feasible by the presence of a hepatic artery arising from superior mesenteric artery. The complexity of having it does not seem to influence in tumor resection margins, complications and survival.

  12. Spinal Ischemia in Thoracic Aortic Procedures: Impact of Radiculomedullary Artery Distribution.

    Science.gov (United States)

    Kari, Fabian A; Wittmann, Karin; Krause, Sonja; Saravi, Babak; Puttfarcken, Luisa; Förster, Katharina; Rylski, Bartosz; Maier, Sven; Göbel, Ulrich; Siepe, Matthias; Czerny, Martin; Beyersdorf, Friedhelm

    2017-12-01

    The aim of this study was to assess the influence of thoracic anterior radiculomedullary artery (tARMA) distribution on spinal cord perfusion in a thoracic aortic surgical model. Twenty-six pigs (34 ± 3 kg; study group, n = 20; sham group, n = 6) underwent ligation of the left subclavian artery and thoracic segmental arteries. End points were spinal cord perfusion pressure (SCPP), regional spinal cord blood flow (SCBF), and neurologic outcome with an observation time of 3 hours. tARMA distribution patterns tested for an effect on end points included (1) maximum distance between any 2 tARMAs within the treated aortic segment (0 or 1 segment = small-distance group; >1 segment = large-distance group) and (2) distance between the end of the treated aortic segment and the first distal tARMA (at the level of the distal simulated stent-graft end = group 0; gap of 1 or more segments = group ≥1). The number of tARMA ranged from 3 to 13 (mean, 8). In the large-distance group, SCBF dropped from 0.48 ± 0.16 mL/g/min to 0.3 ± 0.08 mL/g/min (p distribution patterns of tARMAs correlate with the degree of SCBF drop and insufficient reactive parenchymal hyperemia in aortic procedures. Individual ARMA distribution patterns along the treated aortic segment could help us predict the individual risk of spinal ischemia. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Efficacy of prophylactic uterine artery embolization before obstetrical procedures with high risk for massive bleeding

    International Nuclear Information System (INIS)

    Ko, Heung Kyu; Shin, Ji Hoon; Ko, Gi Young; Gwon, Dong Il; Kim, Jin Hyung; Han, Ki Chang; Lee, Shin Wha

    2017-01-01

    To evaluate the safety and efficacy of prophylactic uterine artery embolization (UAE) before obstetrical procedures with high risk for massive bleeding. A retrospective review of 29 female patients who underwent prophylactic UAE from June 2009 to February 2014 was performed. Indications for prophylactic UAE were as follows: dilatation and curettage (D and C) associated with ectopic pregnancy (cesarean scar pregnancy, n = 9; cervical pregnancy, n = 6), termination of pregnancy with abnormal placentation (placenta previa, n = 8), D and C for retained placenta with vascularity (n = 5), and D and C for suspected gestational trophoblastic disease (n = 1). Their medical records were reviewed to evaluate the safety and efficacy of UAE. All women received successful bilateral prophylactic UAE followed by D and C with preservation of the uterus. In all patients, UAE followed by obstetrical procedure prevented significant vaginal bleeding on gynecologic examination. There was no major complication related to UAE. Vaginal spotting continued for 3 months in three cases. Although oligomenorrhea continued for six months in one patient, normal menstruation resumed in all patients afterwards. During follow-up, four had subsequent successful natural pregnancies. Spontaneous abortion occurred in one of them during the first trimester. Prophylactic UAE before an obstetrical procedure in patients with high risk of bleeding or symptomatic bleeding may be a safe and effective way to manage or prevent serious bleeding, especially for women who wish to preserve their fertility

  14. Efficacy of prophylactic uterine artery embolization before obstetrical procedures with high risk for massive bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Heung Kyu; Shin, Ji Hoon; Ko, Gi Young; Gwon, Dong Il; Kim, Jin Hyung; Han, Ki Chang; Lee, Shin Wha [Asan Medical Center, Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    To evaluate the safety and efficacy of prophylactic uterine artery embolization (UAE) before obstetrical procedures with high risk for massive bleeding. A retrospective review of 29 female patients who underwent prophylactic UAE from June 2009 to February 2014 was performed. Indications for prophylactic UAE were as follows: dilatation and curettage (D and C) associated with ectopic pregnancy (cesarean scar pregnancy, n = 9; cervical pregnancy, n = 6), termination of pregnancy with abnormal placentation (placenta previa, n = 8), D and C for retained placenta with vascularity (n = 5), and D and C for suspected gestational trophoblastic disease (n = 1). Their medical records were reviewed to evaluate the safety and efficacy of UAE. All women received successful bilateral prophylactic UAE followed by D and C with preservation of the uterus. In all patients, UAE followed by obstetrical procedure prevented significant vaginal bleeding on gynecologic examination. There was no major complication related to UAE. Vaginal spotting continued for 3 months in three cases. Although oligomenorrhea continued for six months in one patient, normal menstruation resumed in all patients afterwards. During follow-up, four had subsequent successful natural pregnancies. Spontaneous abortion occurred in one of them during the first trimester. Prophylactic UAE before an obstetrical procedure in patients with high risk of bleeding or symptomatic bleeding may be a safe and effective way to manage or prevent serious bleeding, especially for women who wish to preserve their fertility.

  15. The double switch for atrioventricular discordance.

    Science.gov (United States)

    Brawn, William J

    2005-01-01

    Conventional surgery for atrioventricular discordance usually associated with ventricular arterial discordance leaves the morphologic right ventricle in the systemic circulation. Long-term follow-up results with this approach reveal a high incidence of right ventricular failure. The double switch procedure was introduced to restore the morphologic left ventricle to the systemic circulation. This operation is performed in two main ways: the atrial-arterial switch and the atrial switch plus Rastelli procedure. This double switch approach has been successful at least in the medium term in abolishing morphologic right ventricular failure and its associated tricuspid valve regurgitation. In the atrial-arterial switch group, there is an incidence of morphologic left ventricular dysfunction, sometimes associated with neoaortic valve regurgitation, and the minority of cases need aortic valve replacement. The long-term function of the morphologic left ventricle and the aortic valve need careful surveillance in the future. The atrial-Rastelli group of patients has not in the medium term shown evidence of ventricular dysfunction but will require change on a regular basis of their ventricular to pulmonary artery valved conduits.

  16. Implication of the presence of a variant hepatic artery during the Whipple procedure

    Directory of Open Access Journals (Sweden)

    Mercedes Rubio-Manzanares-Dorado

    2015-07-01

    Full Text Available Introduction: The anatomical variants of the hepatic artery may have important implications for pancreatic cancer surgery. The aim of our study is to compare the outcome following a pancreatoduodenectomy (PD in patients with or without a variant hepatic artery arising from superior mesenteric artery. Material and methods: We reviewed 151 patients with periampullary tumoral pathology. All patients underwent oncological PD between January 2005 and February 2012. Our series was divided into two groups: Group A: Patients with a hepatic artery arising from superior mesenteric artery; and Group B: Patients without a hepatic artery arising from superior mesenteric artery. We expressed the results as mean ± standard deviation for continuous variables and percentages for qualitative variables. Statistical tests were considered significant if p < 0.05. Results: We identified 11 patients with a hepatic artery arising from superior mesenteric artery (7.3%. The most frequent variant was an aberrant right hepatic artery (n = 7, following by the accessory right hepatic artery (n = 2 and the common hepatic artery trunk arising from the superior mesenteric artery (n = 2. In 73% of cases the diagnosis of the variant was intraoperative. R0 resection was performed in all patients with a hepatic artery arising from superior mesenteric artery. There were no significant differences in the tumor resection margins and the incidence of postoperative complications. Conclusion: Oncological PD is feasible by the presence of a hepatic artery arising from superior mesenteric artery. The complexity of having it does not seem to influence in tumor resection margins, complications and survival.

  17. Estimate of ovarian dose and entrance skin dose in uterine artery embolization procedures

    International Nuclear Information System (INIS)

    Silva, Marcia C.; Nasser, Felipe; Affonso, Breno B.; Araujo Junior, Raimundo T.; Zlotnik, Eduardo; Messina, Marcos L.; Baracat, Edmund C.

    2010-01-01

    The goal of this study was to estimate the ovarian dose and entrance skin dose (ESD) of patients who underwent uterine artery embolization (UAE) procedure. To achieve this, 49 UAE procedures were accompanied where the parameters of image acquisition were recorded for the calculation of the DEP from the output of the X-ray tube. The estimation of the ovarian dose was carried out by the insertion of a vaginal probe containing 3 TLD's. The obtained values were compared with the results of other authors and a higher value of ovarian dose (28,97 cGy) and ESD (403,57 cGy) was found in this work. Analysis of the results allowed to observe that this result was obtained mainly as a result of the high number of arteriography series and the frames/second rates employed. Following on from these observations, the protocol of EMUT was altered reducing the frames/seg rate from 2 to 1. Efforts with a view to reducing the number of arteriography series also became part of the next proceedings. (author)

  18. The predictive power of depression screening procedures for veterans with coronary artery disease

    Directory of Open Access Journals (Sweden)

    Shankman SA

    2012-04-01

    Full Text Available Stewart A Shankman1*, Jeffrey Nadelson2*, Sarah Kate McGowan1, Ali A Sovari2, Mladen I Vidovich21Department of Psychiatry and Psychology, University of Illinois, 2Department of Cardiology, Jesse Brown VA Medical Center, Chicago, IL, USA*These authors contributed equally to this workAbstract: Depression leads to a worse outcome for patients with coronary artery disease (CAD. Thus, accurately identifying depression in CAD patients is imperative. In many veterans affairs (VA hospitals, patients are screened for depression once a year using the patient health questionnaire (PHQ-9. Although the PHQ-9 is generally considered a specific and sensitive measure of depression, there is reason to believe that these screening procedures may miss a large number of cases of depression within CAD patients and cardiology patients more generally. The goal of this study was to provide data as to the predictive power of this depression screening procedure by (a comparing the prevalence rate of depression identified by the PHQ-9 to known prevalence rates and (b examining whether patients identified as “depressed” also had conditions that consistently co-occur with depression (eg, post-traumatic stress disorder [PTSD], other medical issues. Participants were 813 consecutive patients who received an angiogram in the cardiac catheterization laboratory at a large VA Medical Center. Prevalence of depression was 6.9% in the overall sample and less than 6% when the sample was restricted to CAD patients with significant stenosis. Depression was significantly associated with PTSD, smoking, and alcohol problems. However, depression was not associated with other medical problems such as diabetes, renal failure, peripheral vascular disease, or anemia. In conclusion, the low prevalence rate of depression and lack of associations with comorbid medical problems may suggest that the VA’s depression screening procedures have low sensitivity for identifying depression in CAD

  19. Interpreting instructional cues in task switching procedures: the role of mediator retrieval.

    Science.gov (United States)

    Logan, Gordon D; Schneider, Darryl W

    2006-03-01

    In 3 experiments the role of mediators in task switching with transparent and nontransparent cues was examined. Subjects switched between magnitude (greater or less than 5) and parity (odd or even) judgments of single digits. A cue-target congruency effect indicated mediator use: subjects responded faster to congruent cue-target combinations (e.g., ODD-3) than to incongruent cue-target combinations (e.g., ODD-4). Experiment 1 revealed significant congruency effects with transparent word cues (ODD, EVEN, HIGH, and LOW) and with relatively transparent letter cues (O, E, H, and L) but not with nontransparent letter cues (D, V, G, and W). Experiment 2 revealed significant congruency effects after subjects who were trained with nontransparent letter cues were informed of the relations between cues and word mediators halfway through the experiment. Experiment 3 showed that congruency effects with relatively transparent letter cues diminished over 10 sessions of practice, suggesting that subjects used mediators less as practice progressed. The results are discussed in terms of the role of mediators in interpreting instructional cues.

  20. Endothelial dysfunction and the occurrence of radial artery spasm during transradial coronary procedures: The ACRA-Spasm study

    NARCIS (Netherlands)

    Van Der Heijden, D.J. (Dirk J.); M.A.H. van Leeuwen (Maarten); G.N. Janssens (Gladys N.); Hermie, J. (Jailen); M.J. Lenzen (Mattie); M.J.P.F. Ritt; P.M. van de Ven (Peter); F. Kiemeneij (Ferdinand); N. van Royen (Niels)

    2016-01-01

    textabstractAims: The aim of this study was to analyse the relation between endothelial dysfunction (ED) and the occurrence of radial artery spasm (RAS) during transradial coronary procedures. Methods and results: From May 2014 to June 2015, endothelial function was assessed by EndoPAT and FMD

  1. Peri-procedural complications and associated risk factors in wingspan stent-assistant angioplasty of intracranial artery stenosis

    International Nuclear Information System (INIS)

    Li Zhaoshuo; Li Tianxiao; Wang Ziliang; Bai Weixing; Xue Jiangyu; Zhu Liangfu; Li Li

    2013-01-01

    Objective: To retrospectively evaluate the cerebrovascular complications from stenting for symptomatic intracranial stenosis and to detect the factors associated with complications. Methods: Medical records of Wingspan stenting were reviewed for 306 cases with symptomatic intracranial stenosis from July 2007 to February 2012, including transient ischemic attack, ischemic stroke, death and intracranial hemorrhage as clinical in-hospital complications. The location of lesions included middle cerebral artery level M1 (114 lesions), intracranial portion of the internal carotid artery (50 lesions), vertebral artery 4 (75 lesions), venebro-basilar artery (14 lesions), basilar artery (76 lesions). Complications were evaluated and analyzed to find out whether they were associated with patient-or stenosis-related risk factors using χ"2 test. Results: The technical success rate was 99% (303/306). Cerebrovascular complications rate was 6.9% (21/303), with 1.6% (14/303) of disabling stroke events and 0.7% (2/303) of deaths. Hemorrhagic events were consisted of procedure-related events (3 cases), hyperperfusion (3 cases), ischemic events of perforator stroke (8 cases), transient ischemic attack (3 cases), embolization (2 cases), thrombosis in stent (2 cases). Hemorrhagic events were associated with significantly higher morbidity and mortality rates (χ"2 = 2.908, P < 0.05) and occurred more frequently after treatment of middle cerebral artery stenosis than other lesions (χ"2 = 1.168, P < 0.05). Perforating branches were detected to be affected mainly in the basilar artery than other locations (χ"2 = 4.263, P < 0.05). Conclusion: The complication rates in the study are preliminary consistent with the previously published data. Hemorrhagic events are prone to occur in the treatment of middle cerebral artery stenosis, while perforating branches are affected mainly in the basilar artery. (authors)

  2. Increased prevalence of preeclampsia among women undergoing procedural intervention for renal artery fibromuscular dysplasia.

    Science.gov (United States)

    Vance, Chardonnay J; Taylor, Robert N; Craven, Timothy E; Edwards, Matthew S; Corriere, Matthew A

    2015-08-01

    Renal artery fibromuscular dysplasia (RA-FMD) has a higher prevalence among women and a presumed hormonal etiology. Although preeclampsia has a clinical presentation similar to symptomatic RA-FMD and occurs exclusively in women, associations between these 2 diseases have not been characterized. To explore epidemiologic associations between RA-FMD and preeclampsia, we administered a validated screening instrument for preeclampsia to a cohort of women with a history of pregnancy who had previously been treated with procedural intervention for symptomatic RA stenosis. Women with a history of pregnancy who had previously undergone procedural intervention (including angioplasty and/or bypass) for symptomatic RA stenosis were identified from a prospectively maintained operative registry and screened for remote history of preeclampsia using a validated survey instrument. Univariable associations between RA-FMD and preeclampsia among participants with a history of pregnancy were evaluated using t-tests for continuous factors and chi-squared tests for dichotomous factors. Multivariable associations were evaluated using logistic regression models. A total of 144 women were identified who met the study inclusion criteria, including 94 with atherosclerotic RA stenosis and 50 with RA-FMD. Sixty-nine patients were contacted, 59 consented to participate, and 52 had a history of pregnancy (and therefore were at risk for preeclampsia). Participants completed the survey instrument at a mean of 7.1 ± 3.1 vs. 6.9 ± 3.6 years after RA procedural intervention, respectively. Survey responses indicated a history of preeclampsia in 19/52 (36.5%) of participants overall, including 14/27 (51.9%) with RA-FMD versus 5/20 (20.0%) with RA atherosclerosis (P = 0.02). Preeclampsia remained associated with FMD in a multivariable model adjusting for smoking status, age at time of surgery, and estimated glomerular filtration rate (odds ratio [OR] 9.51, 95% confidence interval [CI] 1.49-60.6, P = 0

  3. Renal artery denervation for treating resistant hypertension : definition of the disease, patient selection and description of the procedure.

    Science.gov (United States)

    Volpe, Massimo; Rosei, Enrico Agabiti; Ambrosioni, Ettore; Cottone, Santina; Cuspidi, Cesare; Borghi, Claudio; De Luca, Nicola; Fallo, Francesco; Ferri, Claudio; Mancia, Giuseppe; Morganti, Alberto; Muiesan, Maria Lorenza; Sarzani, Riccardo; Sechi, Leonardo; Tocci, Giuliano; Virdis, Agostino

    2012-12-01

    Arterial hypertension is responsible for a significant burden of cardiovascular morbidity and mortality, worldwide. Although several rational and integrated pharmacological strategies are available, the control of high blood pressure still remains largely unsatisfactory. Failure to achieve effective blood pressure control in treated hypertensive patients may have a substantial impact on individual global cardiovascular risk, since it significantly increases the risk of developing hypertension-related macrovascular and microvascular complications. Arterial hypertension is arbitrarily defined as 'resistant' or 'refractory' when the recommended blood pressure goals (clinic blood pressure below 140/90 mmHg or below 130/80 mmHg in patients with type 2 diabetes mellitus or nephropathy) are not achieved in the presence of a therapeutic strategy that includes lifestyle changes and at least three classes of antihypertensive drugs, including a diuretic, at adequate doses. Recently, an innovative non-pharmacological option has become available for treating resistant hypertension. Sympathetic denervation of renal arteries is a minimally invasive procedure that is performed via percutaneous access from the femoral artery. It consists of radiofrequency ablation of the afferent and efferent nerves of the renal sympathetic nervous system, with consequent isolation of renal parenchymal and juxtaglomerular structures from abnormal stimulation of the efferent adrenergic system. The present position paper of the Italian Society of Hypertension (SIIA) offers a diagnostic and therapeutic approach for the proper identification and effective clinical management of patients with resistant hypertension, who are candidates for renal artery denervation. These indications may have important implications not only from a clinical point of view, but also from an economic point of view, since a proper identification of patients with true resistant hypertension and an accurate selection of patients

  4. Aortopulmonary collateral flow is related to pulmonary artery size and affects ventricular dimensions in patients after the fontan procedure.

    Directory of Open Access Journals (Sweden)

    Heiner Latus

    Full Text Available BACKGROUND: Aortopulmonary collaterals (APCs are frequently found in patients with a single-ventricle (SV circulation. However, knowledge about the clinical significance of the systemic-to-pulmonary shunt flow in patients after the modified Fontan procedure and its potential causes is limited. Accordingly, the aim of our study was to detect and quantify APC flow using cardiovascular magnetic resonance (CMR and assess its impact on SV volume and function as well as to evaluate the role of the size of the pulmonary arteries in regard to the development of APCs. METHODS: 60 patients (mean age 13.3 ± 6.8 years after the Fontan procedure without patent tunnel fenestration underwent CMR as part of their routine clinical assessment that included ventricular functional analysis and flow measurements in the inferior vena cava (IVC, superior vena cava (SVC and ascending aorta (Ao. APC flow was quantified using the systemic flow estimator: (Ao - (IVC + SVC. Pulmonary artery index (Nakata index was calculated as RPA + LPA area/body surface area using contrast enhanced MR angiography. The patient cohort was divided into two groups according to the median APC flow: group 1 0.495 l/min/m(2. RESULTS: Group 1 patients had significant smaller SV enddiastolic (71 ± 16 vs 87 ± 25 ml/m(2; p=0.004 and endsystolic volumes (29 ± 11 vs 40 ± 21 ml/m(2; p=0.02 whereas ejection fraction (59 ± 9 vs 56 ± 13%; p=0.38 differed not significantly. Interestingly, pulmonary artery size showed a significant inverse correlation with APC flow (r=-0.50, p=0.002. CONCLUSIONS: Volume load due to APC flow in Fontan patients affected SV dimensions, but did not result in an impairment of SV function. APC flow was related to small pulmonary artery size, suggesting that small pulmonary arteries represent a potential stimulus for the development of APCs.

  5. A Hamiltonian viewpoint in the modeling of switching power converters : A systematic modeling procedure of a large class of switching power converters using the Hamiltonian approach

    NARCIS (Netherlands)

    Escobar, Gerardo; Schaft, Arjan J. van der; Ortega, Romeo

    1999-01-01

    In this paper we show how, using the Hamiltonian formalism, we can systematically derive mathematical models that describe the behaviour of a large class of switching power converters, including the "Boost", "Buck", "Buck-Boost", "Čuk" and "Flyback" converters. We follow the approach earlier

  6. Resection of tumors of the neck of the pancreas with venous invasion: the "Whipple at the Splenic Artery (WATSA)" procedure.

    Science.gov (United States)

    Strasberg, Steven M; Sanchez, Luis A; Hawkins, William G; Fields, Ryan C; Linehan, David C

    2012-05-01

    Tumors of the neck of the pancreas may involve the superior mesenteric and portal veins as well as the termination of the splenic vein. This presents a difficult problem since the pancreas cannot be transected through the neck as is standard in a Whipple procedure. Here, we present our method of resecting such tumors, which we term "Whipple at the Splenic Artery (WATSA)". The superior mesenteric and portal veins are isolated below and above the pancreas, respectively. The pancreas and splenic vein are divided just to the right of the point that the splenic artery contacts the superior border of the pancreas. This plane of transection is approximately 2 cm to the left of the pancreatic neck and away from the tumor. The superior mesenteric artery is cleared from the left side of the patient. With the specimen remaining attached only by the superior mesenteric and portal veins, these structures are clamped and divided. Reconstruction is performed with or without a superficial femoral vein graft. The splenic vein is not reconstructed. Ten cases have been performed to date without mortality. We have previously shown that the pattern of venous collateral development following occlusion of the termination of the splenic vein in the manner described is not similar to that of cases of sinistral (left sided) portal hypertension. Whipple at the splenic artery (WATSA) is a safe method for resection of tumors of the neck of the pancreas with vein involvement. It should be performed in high-volume pancreatic surgery centers.

  7. Effectiveness of sublingual nitroglycerin before puncture compared with conventional intra-arterial nitroglycerin in transradial procedures: a randomized trial

    Energy Technology Data Exchange (ETDEWEB)

    Turan, Burak, E-mail: drburakturan@gmail.com; Daşlı, Tolga; Erkol, Ayhan; Erden, İsmail

    2015-10-15

    Aim: Sublingual (SL) nitroglycerin administered before radial artery puncture can improve cannulation success and decrease the incidence of radial artery spasm (RAS) compared with intra-arterial (IA) nitroglycerin in transradial procedures. Methods: Patients undergoing diagnostic transradial angiography were randomized to IA (200 mcg) or SL (400 mcg) nitroglycerin. Primary endpoints were puncture time and puncture attempts. Secondary endpoint was the incidence of RAS. Results: Total of 101 participants (mean age 60 ± 11 years, 53% male) were randomized (51 in IA and 50 in SL groups). Puncture time (50 [36–75] vs 50 [35–90] sec), puncture attempts (1.18 ± 0.48 vs 1.20 ± 0.49), multiple punctures (13.7 vs 16.0%) and RAS (19.6 vs 24.0%) were not statistically different between IA vs SL groups respectively. A composite endpoint of all adverse events related to transradial angiography (multiple punctures, RAS, access site crossover, hypotension/bradycardia associated with nitroglycerin and radial artery occlusion) was very similar in IA vs SL groups (39 vs 40%, respectively). However puncture time was significantly longer with SL nitroglycerin in patients < 1.65 m height (47 [36–66] vs 63 [41–110] sec, p = 0.042). Multiple punctures seemed higher with SL nitroglycerin in patients with diabetes (0 vs 30%, p = 0.028) or in patients < 1.65 m height (7.4 vs 25%, p = 0.085). Likewise, RAS with SL nitroglycerin seemed more frequent in smokers compared to IA nitroglycerin (0 vs 27%, p = 0.089). Conclusions: SL nitroglycerin was not different from IA nitroglycerin in terms of efficiency and safety in overall study population. However it may be inferior to IA nitroglycerin in certain subgroups (shorter individuals, diabetics and smokers). - Highlights: • Improvement in radial artery puncture time and success with subcutaneous nitrate was reported. • Giving nitrate sublingually may have vasodilation along entire length of radial artery and may prevent RAS

  8. Do dental procedures affect lung function and arterial oxygen saturation in asthmatic patients?

    Directory of Open Access Journals (Sweden)

    Magdy Mahmoud Emara

    2013-04-01

    Conclusion: Asthmatic patients may be at a higher risk of developing oxygen desaturation after dental procedures regardless of their type with and without local anesthesia and a decrease in PEF after dental procedures with local anesthesia.

  9. Comparison of systemic right ventricular function in transposition of the great arteries after atrial switch and congenitally corrected transposition of the great arteries.

    Science.gov (United States)

    Morcos, Michael; Kilner, Philip J; Sahn, David J; Litt, Harold I; Valsangiacomo-Buechel, Emanuela R; Sheehan, Florence H

    2017-12-01

    In patients with transposition of the great arteries corrected by interatrial baffle (TGA) and those with congenitally corrected transposition of the great arteries (ccTGA) the right ventricle (RV) is subjected to systemic pressure and fails prematurely. Previous studies have demonstrated RV dysfunction may be more pronounced in patients with TGA. The present study sought to compare patients with TGA and ccTGA using three-dimensional (3D) techniques to comprehensively analyze the shape, volume, global and regional function in the systemic RV. We compared RV size, shape, and regional and global function in 25 patients with TGA, 17 patients with ccTGA, and 9 normal subjects. The RVs were reconstructed from cardiac Magnetic Resonance Images for 3D analyses. Compared to normal, the RV in TGA and ccTGA was dilated, rounded, and reduced in function. Compared to each other, TGA and ccTGA patients had similar RV size and shape. Global RV function was lower in TGA than ccTGA when assessed from ejection fraction (EF) (30 ± 7 vs. 35 ± 7, p = 0.02) and from normalized tricuspid annular systolic plane excursion (TAPSE) (0.10 ± 0.04 vs. 0.18 ± 0.04, p < 0.01). Basilar RV function was poorer in the TGA patients when compared to ccTGA. The systemic RVs in both TGA and ccTGA are dilated, spherical, and poorly functioning. Compared to ccTGA, TGA RVs have reduced TAPSE and worse basilar hypokinesis.

  10. Large Renal Artery Aneurysm Treated with Guglielmi Detachable Coils: Procedural and 4-Year Follow-up Results

    International Nuclear Information System (INIS)

    Damascelli, Bruno; Bartorelli, Antonio L.; Ticha, Vladimira; Trabattoni, Daniela; Lanocita, Rodolfo

    2008-01-01

    A large aneurysm of the left renal artery was found incidentally during abdominal ultrasound in a 39-year-old woman with no medical or family history of cardiovascular disease. Vascular pathology with a dysplastic appearance was confirmed by magnetic resonance angiography and the patient was offered transcatheter embolization. Since the position and size of the neck of the aneurysm could not be determined at angiography, detachable platinum coils were used for occlusion. The procedure was performed without complications. During a 4-year follow-up no alterations of renal function, recanalization of the aneurysm, or perfusion defects in the rest of the left renal circulation were noted.

  11. Frequent change of procedure during coronary artery bypass surgery suggests insufficient preoperative diagnostic strategy

    DEFF Research Database (Denmark)

    Eckardt, Rozy; Kjeldsen, Bo Juel; Thayssen, Per

    2007-01-01

    We sought to evaluate how often and in what way surgeons change peroperatively their preoperative coronary artery bypass grafting strategy and to what degree these changes affect postoperative graft patency. A series of 109 patients with stable angina pectoris and at least one occluded coronary...... a discrepancy in 22% of the patients, resulting in a lower or higher number of grafts than pre-operatively estimated. The difference in shift rates between the three sites, left anterior descending, left circumflex, and right coronary artery, was significant (P=0.014). Patency rates were highest when only...... preoperatively planned grafts were inserted. When shifts occurred, no matter in which direction, it resulted in a decreased patency rate of the inserted grafts. This finding was significant for LAD (P=0.037). Our findings might indicate the necessity of future studies with the use of scintigraphy or fractional...

  12. Innominate artery injury: a catastrophic complication of tracheostomy, operative procedure revisited.

    Science.gov (United States)

    Maruti Pol, Manjunath; Gupta, Amit; Kumar, Subodh; Mishra, Biplab

    2014-04-03

    A patient presented with profuse bleeding from the oronasal cavity following orofaciomaxillary trauma associated with tracheolaryngeal injury and suspected cervical-spine injury due to collapse of a wall on the face, neck and upper chest. The patient was gasping, coughing blood and was unable to speak. Threatened airway was diagnosed. Inability to maintain oxygenation on cricothyroidotomy, forced emergency department surgeons to shift the patient to the operating room for definitive airway. During tracheostomy a major vessel was injured. Application of vascular clamp in the event of achieving haemostasis resulted in disappearance of saturation and pulse in the right upper limb, thus we suspected innominate artery (IA) injury. High tracheostomy performed and endotracheal tube passed into the trachea after removing clot and overcoming compromised narrow tracheal lumen. The injured IA was repaired and the patient survived for 14 days. On postoperative day 14 he died following profound bleeding into the tracheobronchial tree and asphyxia/apnoea. Tracheoinnominate artery fistula was detected at autopsy.

  13. Music and 25% glucose for preterm babies during the pre-procedure for arterial puncture: facial mimics emphasis

    Directory of Open Access Journals (Sweden)

    Maria Vera Lúcia Moreira Leitão Cardoso

    2016-06-01

    Full Text Available We aimed to describe and quantify facial mimic movements of preterm babies during music and 25% glucose interventions at the pre-procedure for arterial puncture. A randomized controlled trial involving 48 videos of preterm attended in a public neonatal unit, in Fortaleza – Ceará. We collected data from footage analyses during the pre-procedure. Babies heard a lullaby song for 10 minutes in the experimental group; we administered 25% glucose in the control group at the end of the eighth minute, matching a total of 10 minutes of observation. We assessed the frequency of facial expressions: cry, sneeze, yawn, frown the forehead, focused sight, vague sight, sleeping and head movement. Statistically significant variable for the control group: vague sight (p=0.001 at the two last minutes of observation. We concluded that there was no association between most of facial movements and the studied interventions, except for a vague sight in the control group.

  14. Switching the Loaded Agent from Epirubicin to Cisplatin: Salvage Transcatheter Arterial Chemoembolization with Drug-eluting Microspheres for Unresectable Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Seki, Akihiko; Hori, Shinich

    2012-01-01

    Purpose: There is no consensus on switching anticancer agents loaded onto drug carriers in transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). This study aimed to evaluate the safety and clinical outcomes of TACE with cisplatin-loaded microspheres (CLM-TACE) in HCC patients refractory to TACE with epirubicin-loaded microspheres (ELM-TACE). Methods: Between February 2008 and June 2010, 85 patients with unresectable HCC refractory to ELM-TACE were enrolled to undergo CLM-TACE. The number of ELM-TACE sessions until judgment of resistance ranged from 1 to 4 (median, 2.1). CLM-TACE was performed using 50–100-μm superabsorbent polymer microspheres loaded with 1 mg cisplatin/1 mg microspheres together with hepatic arterial infusion of 25 mg cisplatin and 500 mg 5-fluorouracil per patient. Tumor responses were evaluated by computed tomography according to the European Association for the Study of the Liver criteria. Results: The median number of CLM-TACE treatment sessions was 1.8 (range, 1–5), and the mean total dose of cisplatin per session was 42.8 mg (range, 30.0–59.0). After 6 months, 3 (3.5%) patients achieved complete response, 31 (36.5%) had partial response, 15 (17.6%) had stable disease, and 36 (42.4%) had progressive disease. The median overall survival and time to treatment failure after initial CLM-TACE were 13.3 and 7.2 months, respectively. Overall, 9.4% of patients experienced grade 3/4 adverse events. Conclusions: witching the loaded agent from epirubicin to cisplatin is a safe, well-tolerated, and efficacious treatment strategy for salvage TACE with drug-eluting microspheres in HCC patients refractory to ELM-TACE.

  15. Comparison of closed-cell and hybrid-cell stent designs in carotid artery stenting: clinical and procedural outcomes

    Directory of Open Access Journals (Sweden)

    Ersan TatlI

    2017-05-01

    Full Text Available Introduction: Carotid artery stenting (CAS is a promising alternative to surgery in high-risk patients. However, the impact of stent cell design on outcomes in CAS is a matter of continued debate. Aim : To compare the periprocedural and clinical outcomes of different stent designs for CAS with distal protection devices. Material and methods : All CAS procedures with both closed- and hybrid-cell stents performed at our institution between February 2010 and December 2015 were analyzed retrospectively. Adverse events were defined as death, major stroke, minor stroke, transient ischemic attack and myocardial infarction. Periprocedural and 30-day adverse events and internal carotid artery (ICA vasospasm rates were compared between the closed-cell and hybrid-cell stent groups. Results : The study included 234 patients comprising 146 patients with a closed-cell stent (Xact stent, Abbott Vascular (mean age: 68.5 ±8.6; 67.1% male and 88 patients with a hybrid-cell stent (Cristallo Ideale, Medtronic (mean age: 67.2 ±12.8; 68.2% male. There was no significant difference between the groups with respect to periprocedural or 30-day adverse event rates. While there was no difference in terms of tortuosity index between the groups, there was a higher procedural ICA vasospasm rate in the closed-cell stent group (35 patients, 23% compared with the hybrid-cell stent group (10 patients, 11% (p = 0.017. Conclusions : The results of this study showed no significant difference in the clinical adverse event rates after CAS between the closed-cell stent group and the hybrid-cell stent group. However, procedural ICA vasospasm was more common in the closed-cell stent group.

  16. Radial artery anomalies in patients undergoing transradial coronary procedures – An Egyptian multicenter experience

    Directory of Open Access Journals (Sweden)

    Ayman K.M. Hassan

    2016-03-01

    Conclusion: There is a relatively significant presence of radial anomalies, with different degrees of impact on procedural failure rate, in our Egyptian population. Further collaborative studies are recommended to increase our success rates.

  17. In vivo MRI assessment of permanent middle cerebral artery occlusion by electrocoagulation: pitfalls of procedure

    Science.gov (United States)

    2010-01-01

    Permanent middle cerebral artery (MCA) occlusion (pMCAO) by electrocoagulation is a commonly used model but with potential traumatic lesions. Early MRI monitoring may assess pMCAO for non-specific brain damage. The surgical steps of pMCAO were evaluated for traumatic cerebral injury in 22 Swiss mice using diffusion and T2-weighted MRI (7T) performed within 1 h and 24 h after surgery. Temporal muscle cauterization without MCA occlusion produced an early T2 hyperintensity mimicking an infarct. No lesion was visible after temporal muscle incision or craniotomy. Early MRI monitoring is useful to identify non-specific brain injury that could hamper neuroprotective drugs assessment. PMID:20298536

  18. Noninvasive testing in coronary artery disease. Selection of procedures and interpretation of results

    International Nuclear Information System (INIS)

    Sox, H.C. Jr.

    1983-01-01

    In patients with acute chest pain, selection of diagnostic tests and admission to and discharge from the coronary care unit are critical decisions for which useful empirical guidelines are now available. In hospitalized patients, the serum level of the MB fraction of creatine kinase is particularly useful when the history strongly suggests infarction but the ECG is nondiagnostic. In patients with chronic chest pain, the gender of the patient and the character of the pain are the most important guides to selecting and interpreting exercise tests. In women and in men with nonanginal chest pain, the myocardial scintiscan is preferred to the exercise ECG because of its greater diagnostic accuracy. In men with atypical angina, the two tests are nearly equivalent, and the added cost of the scintiscan is a factor in test selection. Since nearly all men with typical angina have coronary artery disease, diagnostic tests are usually not needed

  19. Transcatheter aortic valve implantation and off-pump coronary artery bypass surgery: an effective hybrid procedure in selected patients.

    Science.gov (United States)

    Mayr, Benedikt; Firschke, Christian; Erlebach, Magdalena; Bleiziffer, Sabine; Krane, Markus; Joner, Michael; Herold, Ulf; Nöbauer, Christian; Lange, Rüdiger; Deutsch, Marcus-André

    2018-02-26

    Simultaneous surgical off-pump coronary revascularization and transcatheter aortic valve implantation (TAVI) as a hybrid procedure may be a therapeutic option for patients with a TAVI indication who are not suitable for percutaneous coronary intervention and for patients who have an indication for combined surgical aortic valve implantation and coronary artery bypass grafting but present with a porcelain aorta. Early outcomes of these patients are analysed in this study. From February 2011 to April 2017, hybrid TAVI/off-pump coronary artery bypass (OPCAB) was performed in 12 (60%) patients, hybrid TAVI/minimally invasive direct coronary artery bypass in 6 (30%) patients and staged TAVI/OPCAB in 2 (10%) patients. Endpoints of this study were 30-day mortality, device success and postoperative adverse events as defined by the updated Valve Academic Research Consortium (VARC-2). The median age at the time of surgery was 77 years [interquartile range (IQR), 70-81] with a median logistic EuroSCORE and Society of Thoracic Surgeons' Predicted Risk score of 16.1% (IQR, 9.3-28.1) and 3.9% (IQR, 2.2-5.6), respectively. The median Synergy between PCI with Taxus and Cardiac Surgery score was 16.5 (IQR, 9.8-22.8). TAVI implantation routes were transaortic in 9 (45%) patients, transapical and transfemoral in 5 (25%) patients each and transsubclavian in 1 (5%) patient. Complete myocardial revascularization was achieved in 75% of patients. Device success rate was 100%. Paravalvular aortic regurgitation did not exceed mild in any patient. Stroke/transient ischaemic attack, vascular complications and myocardial infarction were not observed. Re-exploration for bleeding was required in 1 (5%) patient. Thirty-day mortality was 0%. Hybrid OPCAB/MIDCAB and TAVI prove to be a safe and effective alternative treatment option in selected higher risk patients.

  20. Status of systemic to pulmonary arterial collateral flow after the fontan procedure.

    Science.gov (United States)

    Whitehead, Kevin K; Harris, Matthew A; Glatz, Andrew C; Gillespie, Matthew J; DiMaria, Michael V; Harrison, Neil E; Dori, Yoav; Keller, Marc S; Rome, Jonathan J; Fogel, Mark A

    2015-06-15

    The investigators recently validated a method of quantifying systemic-to-pulmonary arterial collateral flow using phase-contrast magnetic resonance imaging velocity mapping. Cross-sectional data suggest decreased collateral flow in patients with total cavopulmonary connections (TCPCs) compared with those with superior cavopulmonary connections (SCPCs). However, no studies have examined serial changes in collateral flow from SCPCs to TCPCs in the same patients. The aim of this study was to examine differences in collateral flow between patients with SCPCs and those with TCPCs. Collateral flow was quantified by 2 independent measures from 250 single-ventricle studies in 219 different patients (115 SCPC and 135 TCPC studies, 31 patients with both) and 18 controls, during routine studies using through-plane phase-contrast magnetic resonance imaging. Collateral flow was indexed to body surface area, aortic flow, and pulmonary venous flow. Regardless of indexing method, SCPC patients had significantly higher collateral flow than TCPC patients (1.64 ± 0.8 vs 1.03 ± 0.8 L/min/m(2), p <0.001). In 31 patients who underwent serial examinations, collateral flow as a fraction of aortic flow increased early after TCPC completion. In TCPC patients, indexed collateral flow demonstrated a significant negative correlation with time from TCPC. In conclusion, SCPC and TCPC patients demonstrate substantial collateral flow, with SCPC patients having higher collateral flow than TCPC patients overall. On the basis of the paired subset analysis, collateral flow does not decrease in the short term after TCPC completion and trends toward an increase. In the long term, however, collateral flow decreases over time after TCPC completion. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins

    International Nuclear Information System (INIS)

    Buecker, A.; Gross-Fengels, W.; Haage, P.; Huppert, P.; Landwehr, P.; Loose, R.; Reimer, P.; Tacke, J.; Vorwerk, D.; Fischer, J.

    2012-01-01

    The topics covered in the qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins are the following: Practical qualification: aorta iliac vessels and vessels in the upper and lower extremities, kidney and visceral arteries, head and neck arteries, dialysis shunts, veins and pulmonary arteries, aorta aneurysms and peripheral artery aneurysms. Knowledge acquisition concerning radiation protection: legal fundamentals, education and training, knowledge actualization and quality control, definition of the user and the procedure, competence preservation.

  2. Ubiquitous Nature of Distal Athero/Thromboembolic Events during Lower Extremity Atherectomy Procedures Involving the Superficial Femoral Artery

    Science.gov (United States)

    Wasty, Najam; Khakwani, M. Z.; Kotev, Spas; Boiangiu, Catalin; Hasan, Omar; Anna, Manjusha; Tayal, Rajiv; Kaid, Khalil; Baker, Gail; Cohen, Marc

    2016-01-01

    This study aims to evaluate occurrence, size, composition, and clinical significance of embolized debris during superficial femoral artery atherectomy using all commercially available atherectomy devices. Distal athero/thromboembolic events (DATE) are a universal phenomenon in lower extremity atherectomy procedures (LEAPs) due to the sheer volume of atheroma and the thrombus burden in peripheral arterial disease. Some of these events can be clinically significant. We prospectively gathered clinical and histopathological data on all commercially available atherectomy devices by using embolic protection devices (EPD) in every case. After intervention, the contents of EPD were examined both microscopically and macroscopically. Data from 59 consecutive patients undergoing LEAP were analyzed. DATE occurred 100% of the time. The composition of particulate debris varied with the device used. Grossly visible agglomerated debris was captured by the filter in the majority of patients 54/59 (91.5%). Clinically significant debris, defined by the Preventing Lower Extremity Distal Embolization Using Embolic Filter Protection registry as particle diameter > 0.2 cm, was found in 33/59 (56%) patients. The size of captured debris particles ranged from 0.1 to 2.4 mm. While DATE occurred in all patients, clinically significant DATE occurred in 56% patients undergoing LEAP regardless of the atherectomy device. In spite of a large fraction of the clinically significant debris occurring on our routine dual antiplatelet regimen, no patient suffered an amputation. Although DATE was prevented by the use of EPD in all 59 cases, more data are needed to determine whether the use of EPD translates into a long-term clinical benefit. Use of EPD and optimal thromboprophylaxis should be considered in patients, especially in the setting of compromised distal runoff. PMID:27867291

  3. A rare case of large isolated internal iliac artery aneurysm with ureteral obstruction and hydronephrosis: Compression symptoms are limitation for endovascular procedures.

    Science.gov (United States)

    Nenezic, Dragoslav; Tanaskovic, Slobodan; Gajin, Predrag; Ilijevski, Nenad; Novakovic, Aleksandra; Radak, Djordje

    2015-04-01

    In this report, we aim to present a rare case of isolated internal iliac artery aneurysm with associated left ureteric obstruction and consequent hydronephrosis. A 66-year-old male patient was admitted for occasional pain in the lower back that appeared one month earlier. CT arteriography revealed isolated internal iliac artery (diameter 99 mm) with ureteral obstruction, hydroureter and left kidney hydronephrosis occurrence. Aneurysm was resected, after six months the patient was doing well. Bearing in mind that 77% of the patients with isolated internal iliac artery have symptoms caused by aneurysmal compression on adjacent organs, we wanted to highlight that despite the amazing expansion of endovascular procedures in the last decades, its therapeutic effect in isolated internal iliac artery's treatment is to a great extent limited since compression symptoms cannot be solved. Open surgery remains the gold standard for isolated internal iliac artery's treatment considering significant limitations of endovascular procedures due to the inability to eliminate problems caused by compression. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  4. Text mining applied to electronic cardiovascular procedure reports to identify patients with trileaflet aortic stenosis and coronary artery disease.

    Science.gov (United States)

    Small, Aeron M; Kiss, Daniel H; Zlatsin, Yevgeny; Birtwell, David L; Williams, Heather; Guerraty, Marie A; Han, Yuchi; Anwaruddin, Saif; Holmes, John H; Chirinos, Julio A; Wilensky, Robert L; Giri, Jay; Rader, Daniel J

    2017-08-01

    Interrogation of the electronic health record (EHR) using billing codes as a surrogate for diagnoses of interest has been widely used for clinical research. However, the accuracy of this methodology is variable, as it reflects billing codes rather than severity of disease, and depends on the disease and the accuracy of the coding practitioner. Systematic application of text mining to the EHR has had variable success for the detection of cardiovascular phenotypes. We hypothesize that the application of text mining algorithms to cardiovascular procedure reports may be a superior method to identify patients with cardiovascular conditions of interest. We adapted the Oracle product Endeca, which utilizes text mining to identify terms of interest from a NoSQL-like database, for purposes of searching cardiovascular procedure reports and termed the tool "PennSeek". We imported 282,569 echocardiography reports representing 81,164 individuals and 27,205 cardiac catheterization reports representing 14,567 individuals from non-searchable databases into PennSeek. We then applied clinical criteria to these reports in PennSeek to identify patients with trileaflet aortic stenosis (TAS) and coronary artery disease (CAD). Accuracy of patient identification by text mining through PennSeek was compared with ICD-9 billing codes. Text mining identified 7115 patients with TAS and 9247 patients with CAD. ICD-9 codes identified 8272 patients with TAS and 6913 patients with CAD. 4346 patients with AS and 6024 patients with CAD were identified by both approaches. A randomly selected sample of 200-250 patients uniquely identified by text mining was compared with 200-250 patients uniquely identified by billing codes for both diseases. We demonstrate that text mining was superior, with a positive predictive value (PPV) of 0.95 compared to 0.53 by ICD-9 for TAS, and a PPV of 0.97 compared to 0.86 for CAD. These results highlight the superiority of text mining algorithms applied to electronic

  5. A novel multi-wavelength procedure for blood pressure estimation using opto-physiological sensor at peripheral arteries and capillaries

    Science.gov (United States)

    Scardulla, Francesco; Hu, Sijung; D'Acquisto, Leonardo; Pasta, Salvatore; Barrett, Laura; Blanos, Panagiotis; Yan, Liangwen

    2018-02-01

    In this study, the Carelight multi-wavelength opto-electronic patch sensor (OEPS) was adopted to assess the effectiveness of a new approach for estimating the systolic blood pressure (SBP) through the changes in the morphology of the OEPS signal. Specifically, the SBP was estimated by changing the pressure exerted on an inflatable cuff placed around the left upper arm. Pressure acquisitions were performed both with gold standard (i.e. electronic sphygmomanometer), and Carelight sensor (experimental procedure), on subjects from a multiethnic cohort (aged 28 +/- 7). The OEPS sensor was applied together with a manual inflatable cuff, going slightly above the level of the SBP with increases of +10mmHg and subsequently deflated by 10mmHg until reaching full deflation. The OEPS signals were captured using four wavelength illumination sources (i.e., green 525 nm, orange 595 nm, red 650 nm and IR 870 nm) on three different measuring sites, namely forefinger, radial artery and wrist. The implemented algorithm provides information on the instant when the SBP was reached and the signal is lost since the vessel is completely blocked. Similarly, it detected the signal resumption when the external pressure dropped below the SBP. The findings demonstrated a good correlation between the variation of the pressure and the corresponding OEPS signal with the most accurate result achieved in the fingertip among all wavelengths, with a temporal identification error of 8.07 %. Further studies will improve the clinical relevance on a cohort of patients diagnosed with hyper- or hypotension, in order to develop a wearable blood-pressure device.

  6. Repair of left coronary artery aneurysm, recurrent ascending aortic aneurysm, and mitral valve prolapse 19 years after Bentall's procedure in a patient with Marfan syndrome.

    Science.gov (United States)

    Badmanaban, Balaji; Mallon, Peter; Campbell, Norman; Sarsam, Mazin A I

    2004-01-01

    A 45-year-old female with Marfan syndrome had a Bentall's procedure performed 19 years ago. She presented with a 4-year history of gradually worsening dyspnea and decreasing exercise tolerance. Investigations revealed severe mitral valve prolapse, a left main stem coronary artery (LMSCA) aneurysm, and a recurrent aneurysm of the ascending aorta. The mitral valve was replaced and the aortic aneurysmal sac and the LMSCA aneurysm were then repaired by a modified Bentall procedure. The patient made an uneventful recovery and was discharged home.

  7. Weaning mechanical ventilation after off-pump coronary artery bypass graft procedures directed by noninvasive gas measurements.

    Science.gov (United States)

    Chakravarthy, Murali; Narayan, Sandeep; Govindarajan, Raghav; Jawali, Vivek; Rajeev, Subramanyam

    2010-06-01

    Partial pressure of carbon dioxide and oxygen were transcutaneously measured in adults after off-pump coronary artery bypass (OPCAB) surgery. The clinical use of such measurements and interchangeability with arterial blood gas measurements for weaning patients from postoperative mechanical ventilation were assessed. This was a prospective observational study. Tertiary referral heart hospital. Postoperative OPCAB surgical patients. Transcutaneous oxygen and carbon dioxide measurements. In this prospective observational study, 32 consecutive adult patients in a tertiary care medical center underwent OPCAB surgery. Noninvasive measurement of respiratory gases was performed during the postoperative period and compared with arterial blood gases. The investigator was blinded to the reports of arterial blood gas studies and weaned patients using a "weaning protocol" based on transcutaneous gas measurement. The number of patients successfully weaned based on transcutaneous measurements and the number of times the weaning process was held up were noted. A total of 212 samples (pairs of arterial and transcutaneous values of oxygen and carbon dioxide) were obtained from 32 patients. Bland-Altman plots and mountain plots were used to analyze the interchangeability of the data. Twenty-five (79%) of the patients were weaned from the ventilator based on transcutaneous gas measurements alone. Transcutaneous carbon dioxide measurements were found to be interchangeable with arterial carbon dioxide during 96% of measurements, versus 79% for oxygen measurements. More than three fourths of the patients were weaned from mechanical ventilation and extubated based on transcutaneous gas values alone after OPCAB surgery. The noninvasive transcutaneous carbon dioxide measurement can be used as a surrogate for arterial carbon dioxide measurement to manage postoperative OPCAB patients. Copyright 2010 Elsevier Inc. All rights reserved.

  8. Day-case peripheral angioplasty using nurse-led admission, discharge, and follow-up procedures: arterial closure devices are not necessary

    Energy Technology Data Exchange (ETDEWEB)

    Kasthuri, R.; Karunaratne, D.; Andrew, H.; Sumner, J. [Department of Radiology, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL (United Kingdom); Chalmers, N. [Department of Radiology, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL (United Kingdom)], E-mail: nicholas.chalmers@cmmc.nhs.uk

    2007-12-15

    Aim: To audit the safety of day-case peripheral arterial intervention without the use of arterial-closure devices using nurse-led admission, discharge, and follow-up procedures. Materials and methods: Patients referred for elective, peripheral vascular intervention were selected for day-case care according to pre-determined criteria using telephone triage. Post-procedure haemostasis was achieved using manual compression. After 3 h bed-rest, patients were mobilized and discharged at 5 h. Patients were contacted by telephone next working day to audit complications. Results: One hundred and eighty-three elective day-case peripheral interventions were performed over 2 years, predominantly using 6 F sheaths. No closure devices were used. Five patients (2%) returned to the department because of persistent groin symptoms the next day. One of these had a false aneurysm. Four required no further treatment. A single patient returned at day 6 with a delayed false aneurysm. Conclusion: Day-case peripheral vascular intervention can be safely performed in appropriately selected patients without the use of arterial closure devices. Specialist radiology nurses have a major role in the counselling, care, and follow-up of these patients.

  9. Day-case peripheral angioplasty using nurse-led admission, discharge, and follow-up procedures: arterial closure devices are not necessary

    International Nuclear Information System (INIS)

    Kasthuri, R.; Karunaratne, D.; Andrew, H.; Sumner, J.; Chalmers, N.

    2007-01-01

    Aim: To audit the safety of day-case peripheral arterial intervention without the use of arterial-closure devices using nurse-led admission, discharge, and follow-up procedures. Materials and methods: Patients referred for elective, peripheral vascular intervention were selected for day-case care according to pre-determined criteria using telephone triage. Post-procedure haemostasis was achieved using manual compression. After 3 h bed-rest, patients were mobilized and discharged at 5 h. Patients were contacted by telephone next working day to audit complications. Results: One hundred and eighty-three elective day-case peripheral interventions were performed over 2 years, predominantly using 6 F sheaths. No closure devices were used. Five patients (2%) returned to the department because of persistent groin symptoms the next day. One of these had a false aneurysm. Four required no further treatment. A single patient returned at day 6 with a delayed false aneurysm. Conclusion: Day-case peripheral vascular intervention can be safely performed in appropriately selected patients without the use of arterial closure devices. Specialist radiology nurses have a major role in the counselling, care, and follow-up of these patients

  10. Testicular artery arising from an aberrant right renal artery | Suluba ...

    African Journals Online (AJOL)

    This case report we discovered the rare variation of the origin of the right testicular artery arising from the right aberrant renal artery with double renal artery irrigating both left and right kidneys. These variations in the testicular arteries and renal arteries have implication to surgical procedures such as orchidopexy repair for ...

  11. Does a similar procedure result in similar survival for women and men undergoing isolated coronary artery bypass grafting?

    Science.gov (United States)

    Attia, Tamer; Koch, Colleen G; Houghtaling, Penny L; Blackstone, Eugene H; Sabik, Ellen Mayer; Sabik, Joseph F

    2017-03-01

    To (1) identify sex-related differences in risk factors and revascularization strategies for patients undergoing coronary artery bypass grafting (CABG), (2) assess whether these differences influenced early and late survival, and (3) determine whether clinical effectiveness of the same revascularization strategy was influenced by sex. From January 1972 to January 2011, 57,943 adults-11,009 (19%) women-underwent primary isolated CABG. Separate models for long-term mortality were developed for men and women, followed by assessing sex-related differences in strength of risk factors (interaction terms). Incomplete revascularization was more common in men than women (26% vs 22%, P  .9) with lower survival in both sexes. Single ITA grafting was associated with equally (P = .3) better survival in women and men. Although bilateral ITA grafting was associated with better survival than single ITA grafting, it was less effective in women-11% lower late mortality (hazard ratio, 0.89 [0.77-1.022]) versus 27% lower in men (hazard ratio, 0.73 [0.69-0.77]; P = .01). Women on average have longer life expectancies than men but not after CABG. Every attempt should be made to use arterial grafting and complete revascularization, but for unexplained reasons, sex-related differences in effectiveness of bilateral arterial grafting were identified. Copyright © 2016. Published by Elsevier Inc.

  12. Subanalysis of the CONFIRM Registries: Acute Procedural Outcomes in Claudicant and Critical Limb Ischemia Patients With Varying Levels of Calcification Treated for Peripheral Arterial Disease With Orbital Atherectomy.

    Science.gov (United States)

    Adams, George L; Das, Tony; Lee, Michael S; Beasley, Robert; Mustapha, Jihad

    2015-11-01

    Patients with peripheral arterial disease (PAD) can be classified into groups based upon the severity of the disease using the Rutherford classification system. This analysis compares the procedural outcomes of PAD patients treated with orbital atherectomy stratified by Rutherford class (1-3 = intermittent claudication; 4-6 = critical limb ischemia [CLI]), and acute angiographic outcomes of these patients stratified by degree of lesion calcification. The CONFIRM registry series was analyzed and included 1697 patients with intermittent claudication (Rutherford class 1-3) and 1320 patients with CLI (Rutherford class 4-6) treated with orbital atherectomy. The composite rate of dissection, perforation, slow-flow, vessel closure, spasm, embolism, and thrombus formation was compared between claudicants and CLI patients with varying degrees of lesion calcification. Patients with CLI were older and had a higher prevalence of diabetes, coronary artery disease, and renal disease (Patherectomy resulted in similar low procedural complication rates in the CLI group compared with the claudicant group. These results suggest that orbital atherectomy is safe and effective for treating calcified lesions in high-risk patients with varying severity of PAD symptoms.

  13. Acute procedural outcomes of orbital atherectomy for the treatment of common femoral artery disease: Sub-analysis of the CONFIRM Registries.

    Science.gov (United States)

    Lee, Michael S; Heikali, Daniel; Mustapha, Jihad; Adams, George; Mahmud, Ehtisham

    2017-08-01

    This analysis compared the angiographic outcomes of patients treated with orbital atherectomy for calcified common femoral artery (CFA) and superficial femoral artery (SFA) disease. The ideal revascularization strategy for CFA disease is unknown. Endarterectomy has been considered the standard of care for CFA disease for over 50 years. Endovascular intervention is becoming more commonly used to revascularize the CFA given the advances in technology and the less invasive nature of the procedure. Patient demographics, lesion characteristics, and procedure data for all CONFIRM patients with at least one CFA lesion location ( n=147 patients; n=200 lesions) were compared to patients with at least one SFA lesion location ( n=1508 patients; n=2367 lesions). The primary endpoint was angiographic complication, defined as the composite of dissection, perforation, slow flow, closure, spasm, embolism, or thrombosis. The CFA group had more patients with Rutherford class 4 and shorter lesion length. The CFA group had a higher final residual stenosis, shorter total run time, and shorter total inflation time. The primary endpoint was lower in the CFA group compared with the SFA group (17% vs 24%, p=0.02), driven by a lower dissection rate (10% vs 15%, p=0.04). Plaque modification of the CFA with orbital atherectomy was safe and compared favorably with SFA disease. The need for bail-out stenting was low. A randomized trial is needed to determine the ideal treatment strategy for calcified CFA disease.

  14. Jet pump assisted artery

    Science.gov (United States)

    1975-01-01

    A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

  15. Exciter switch

    Science.gov (United States)

    Mcpeak, W. L.

    1975-01-01

    A new exciter switch assembly has been installed at the three DSN 64-m deep space stations. This assembly provides for switching Block III and Block IV exciters to either the high-power or 20-kW transmitters in either dual-carrier or single-carrier mode. In the dual-carrier mode, it provides for balancing the two drive signals from a single control panel located in the transmitter local control and remote control consoles. In addition to the improved switching capabilities, extensive monitoring of both the exciter switch assembly and Transmitter Subsystem is provided by the exciter switch monitor and display assemblies.

  16. Pattern of Venous Collateral Development after Splenic Vein Occlusion in an Extended Whipple Procedure (Whipple at the Splenic Artery) and Long-Term Results.

    Science.gov (United States)

    Rosado, Ismael Dominguez; Bhalla, Sanjeev; Sanchez, Luis A; Fields, Ryan C; Hawkins, William G; Strasberg, Steven M

    2017-03-01

    Extended Whipple procedures may require division of the splenic vein (SV). Controversy exists regarding the risk of sequelae of sinistral portal hypertension when the SV is ligated without reimplantation. The aim of this study was to identify postoperative venous collateral patterns and sequelae of SV ligation, as well as long-term results in an extended Whipple procedure. Patients who had an extended Whipple procedure (Whipple at the Splenic Artery or WATSA) were entered in an institutional database. Evaluation of the venous collaterals was performed at least 5 months postoperatively by imaging. Spleen size and platelet counts were measured before and after operation. Fifteen patients were entered from 2009 to 2014. SV was not reconstructed and the IMV-SV junction was always resected. Two collateral routes developed. An inferior route was present 14/15 patients. It connected the residual SV to the SMV via intermediate collateral veins in the omentum and along the colon. A superior route, present in 10/15 patients connected the residual SV to the portal vein via gastric, perigastric, and coronary veins. Gastrointestinal bleeding did not occur. Mean platelet count and spleen size were not affected significantly. Procedures were long, but few severe complications developed. In 12 patients with adenocarcinoma, the median survival has not been reached. Patients who have SV ligation in an extended Whipple are protected against sequelae of sinestral portal hypertension by inferior collateral routes. The omentum and marginal veins of the colon are key links in this pathway.

  17. Adapting a Markov Monte Carlo simulation model for forecasting the number of Coronary Artery Revascularisation Procedures in an era of rapidly changing technology and policy

    Directory of Open Access Journals (Sweden)

    Knuiman Matthew

    2008-06-01

    Full Text Available Abstract Background Treatments for coronary heart disease (CHD have evolved rapidly over the last 15 years with considerable change in the number and effectiveness of both medical and surgical treatments. This period has seen the rapid development and uptake of statin drugs and coronary artery revascularization procedures (CARPs that include Coronary Artery Bypass Graft procedures (CABGs and Percutaneous Coronary Interventions (PCIs. It is difficult in an era of such rapid change to accurately forecast requirements for treatment services such as CARPs. In a previous paper we have described and outlined the use of a Markov Monte Carlo simulation model for analyzing and predicting the requirements for CARPs for the population of Western Australia (Mannan et al, 2007. In this paper, we expand on the use of this model for forecasting CARPs in Western Australia with a focus on the lack of adequate performance of the (standard model for forecasting CARPs in a period during the mid 1990s when there were considerable changes to CARP technology and implementation policy and an exploration and demonstration of how the standard model may be adapted to achieve better performance. Methods Selected key CARP event model probabilities are modified based on information relating to changes in the effectiveness of CARPs from clinical trial evidence and an awareness of trends in policy and practice of CARPs. These modified model probabilities and the ones obtained by standard methods are used as inputs in our Markov simulation model. Results The projected numbers of CARPs in the population of Western Australia over 1995–99 only improve marginally when modifications to model probabilities are made to incorporate an increase in effectiveness of PCI procedures. However, the projected numbers improve substantially when, in addition, further modifications are incorporated that relate to the increased probability of a PCI procedure and the reduced probability of a CABG

  18. Adapting a Markov Monte Carlo simulation model for forecasting the number of coronary artery revascularisation procedures in an era of rapidly changing technology and policy.

    Science.gov (United States)

    Mannan, Haider R; Knuiman, Matthew; Hobbs, Michael

    2008-06-25

    Treatments for coronary heart disease (CHD) have evolved rapidly over the last 15 years with considerable change in the number and effectiveness of both medical and surgical treatments. This period has seen the rapid development and uptake of statin drugs and coronary artery revascularization procedures (CARPs) that include Coronary Artery Bypass Graft procedures (CABGs) and Percutaneous Coronary Interventions (PCIs). It is difficult in an era of such rapid change to accurately forecast requirements for treatment services such as CARPs. In a previous paper we have described and outlined the use of a Markov Monte Carlo simulation model for analyzing and predicting the requirements for CARPs for the population of Western Australia (Mannan et al, 2007). In this paper, we expand on the use of this model for forecasting CARPs in Western Australia with a focus on the lack of adequate performance of the (standard) model for forecasting CARPs in a period during the mid 1990s when there were considerable changes to CARP technology and implementation policy and an exploration and demonstration of how the standard model may be adapted to achieve better performance. Selected key CARP event model probabilities are modified based on information relating to changes in the effectiveness of CARPs from clinical trial evidence and an awareness of trends in policy and practice of CARPs. These modified model probabilities and the ones obtained by standard methods are used as inputs in our Markov simulation model. The projected numbers of CARPs in the population of Western Australia over 1995-99 only improve marginally when modifications to model probabilities are made to incorporate an increase in effectiveness of PCI procedures. However, the projected numbers improve substantially when, in addition, further modifications are incorporated that relate to the increased probability of a PCI procedure and the reduced probability of a CABG procedure stemming from changed CARP preference

  19. Efficacy and surgical procedures of preoperative splenic artery embolization for laparoscopic splenectomy of a massive splenomegaly: A case report

    Directory of Open Access Journals (Sweden)

    Toshikatsu Nitta

    2015-01-01

    Full Text Available Here, we describe the case of a 58-year-old woman diagnosed with massive splenomegaly with a malignant lymphoma that had a maximum diameter of 24 cm. Splenectomy was indicated because of thrombocytopenia and abdominal distention. Therefore, a balloon catheter was inserted preoperatively through the splenic artery for embolization and continuous infusion to reduce the spleen volume. It enabled easy handling of the spleen and minimized bleeding. The volume of the spleen was estimated at 1896 g through the skin incision, as measured by volumetric computed tomography; thus, laparoscopy seemed difficult. However, the surgery was successfully performed only with laparoscopic surgery, and the volume of the resected spleen was 1020 g. This preoperative preparation is an effective alternative to laparoscopic removal of a huge splenomegaly.

  20. Converting to increased Tc-99m DTPA renal flow from slight decrease in renal flow following angioplastic procedures in a patient with unequal renal artery stenoses

    International Nuclear Information System (INIS)

    Shih Weijen; Mitchell, B.L.

    1990-01-01

    The use of Tc-99m DTPA renal flow imaging has increased in importance since the introduction of catheter angioplasty. The high diagnostic accuracy and non-invasive technique as compared to digital subtraction angiography have done much to enhance its usage in the evaluation of renal functional status. This paper reports Tc-99m DTPA renal flow imaging findings before and after angioplasty in a patient with bilateral renal artery stenosis. The slight decrease in Tc-99m DTPA renal flow on the kidney before angioplasty converted to an increase in flow on the right kidney after angioplasty. Post procedural blood flow was much higher on the right, where stenosis was previously more severe. It is hypothesized that the right kidney was protected from elevated aterial pressure by its 90% arterial stenosis while the left kidney was exposed to elevated systemic blood pressure. Because of vascular damage to the unprotected left kidney, post-angioplasty blood flow was less in the left kidney than in the ischemic but protected right kidney. (orig.) [de

  1. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    International Nuclear Information System (INIS)

    D’Ercole, Loredana; Quaretti, Pietro; Cionfoli, Nicola; Klersy, Catherine; Bocchiola, Milena; Rodolico, Giuseppe; Azzaretti, Andrea; Lisciandro, Francesco; Cascella, Tommaso; Zappoli Thyrion, Federico

    2013-01-01

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 ± 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 ± 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 ± 0.42 Gy) were FR ) were 269 Gy cm 2 , 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1–102.7, p FR overexposures (OR 10.8, 95 % CI 1.1–109.5, p FR overexposure (OR 2.8, 95 % CI 1.1–7.4, p = 0.040). At multivariable analysis, stenosis ≥ 90 % (OR 2.8, 95 % CI 1.1–7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1–109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  2. Impact of lesion location on procedural and acute angiographic outcomes in patients with critical limb ischemia treated for peripheral artery disease with orbital atherectomy: A CONFIRM registries subanalysis.

    Science.gov (United States)

    Lee, Michael S; Mustapha, Jihad; Beasley, Robert; Chopra, Paramjit; Das, Tony; Adams, George L

    2016-02-15

    This analysis compares the procedural and acute angiographic outcomes in patients with critical limb ischemia (CLI) treated with orbital atherectomy in above-the-knee (ATK)/popliteal (POP) lesions versus below-the-knee (BTK) lesions. Lesion location affects the procedural outcomes and the opportunity for limb salvage in patients with CLI suffering from peripheral artery disease (PAD). The CONFIRM registry series was analyzed and includes 1109 real-world patients (1544 lesions) suffering from CLI treated with orbital atherectomy. The rates of dissection, perforation, slow flow, vessel closure, spasm, embolism, and thrombus formation were compared between CLI patients with ATK/POP lesions and BTK lesions. Patients with ATK/POP lesions had a higher final residual stenosis (10 vs. 9%; P = 0.004) and use of more adjunctive therapies (e.g. balloons and stents; 1.3 vs. 1.1%; P atherectomy was successful in CLI patients regardless of lesion location. BTK lesions were associated with increased rates of perforation, slow flow and spasm which may be explained by more challenging procedural characteristics in these patients such as smaller vessel size and tortuosity. The higher incidence of emboli in ATK/POP lesions is most likely attributed to the higher prevalence of severe calcium observed in this cohort. © 2015 Wiley Periodicals, Inc.

  3. Impact of Advanced Age on Procedural and Acute Angiographic Outcomes in Patients Treated for Peripheral Artery Disease With Orbital Atherectomy: A CONFIRM Registries Subanalysis.

    Science.gov (United States)

    Lee, Michael S; Beasley, Robert; Adams, George L

    2015-08-01

    Data on the outcomes of elderly patients with peripheral arterial disease (PAD) who undergo orbital atherectomy are limited. This analysis compares the procedural and acute angiographic outcomes of PAD patients treated with orbital atherectomy stratified by age (≥ 75 years of age [elderly] vs atherectomy. The composite rate of adverse events including dissection, perforation, slow flow, vessel closure, spasm, embolism, and thrombus formation was compared between groups. Elderly patients had a higher proportion of females (47.5% vs 35.3%; Patherectomy resulted in similar composite rates of adverse events despite the elderly having unfavorable baseline Rutherford classification and lesion characteristics. The higher rate of perforation may be explained by longer and more below-the-knee lesions.

  4. EANM procedure guideline for the treatment of liver cancer and liver metastases with intra-arterial radioactive compounds.

    Science.gov (United States)

    Giammarile, Francesco; Bodei, Lisa; Chiesa, Carlo; Flux, Glenn; Forrer, Flavio; Kraeber-Bodere, Françoise; Brans, Boudewijn; Lambert, Bieke; Konijnenberg, Mark; Borson-Chazot, Françoise; Tennvall, Jan; Luster, Markus

    2011-07-01

    Primary liver cancers (i.e. hepatocellular carcinoma or cholangiocarcinoma) are worldwide some of the most frequent cancers, with rapidly fatal liver failure in a large majority of patients. Curative therapy consists of surgery (i.e. resection or liver transplantation), but only 10-20% of patients are candidates for this. In other patients, a variety of palliative treatments can be given, such as chemoembolization, radiofrequency ablation or recently introduced tyrosine kinase inhibitors, e.g. sorafenib. Colorectal cancer is the second most lethal cancer in Europe and liver metastases are prevalent either at diagnosis or in follow-up. These patients are usually treated by a sequence of surgery, chemotherapy and antibody therapy [Okuda et al. (Cancer 56:918-928, 1985); Schafer and Sorrell (Lancet 353:1253-1257, 1999); Leong et al. (Arnold, London, 1999)]. Radioembolization is an innovative therapeutic approach defined as the injection of micron-sized embolic particles loaded with a radioisotope by use of percutaneous intra-arterial techniques. Advantages of the use of these intra-arterial radioactive compounds are the ability to deliver high doses of radiation to small target volumes, the relatively low toxicity profile, the possibility to treat the whole liver including microscopic disease and the feasibility of combination with other therapy modalities. Disadvantages are mainly due to radioprotection constraints mainly for (131)I-labelled agents, logistics and the possibility of inadvertent delivery or shunting [Novell et al. (Br J Surg 78:901-906, 1991)]. The Therapy, Oncology and Dosimetry Committees have worked together in order to revise the European Association of Nuclear Medicine (EANM) guidelines on the use of the radiopharmaceutical (131)I-Lipiodol (Lipiocis®, IBA, Brussels, Belgium) and include the newer medical devices with (90)Y-microspheres. (90)Y is either bound to resin (SIR-Spheres®, Sirtex Medical, Lane Cove, Australia) or embedded in a glass

  5. Pseudospark switches

    International Nuclear Information System (INIS)

    Billault, P.; Riege, H.; Gulik, M. van; Boggasch, E.; Frank, K.

    1987-01-01

    The pseudospark discharge is bound to a geometrical structure which is particularly well suited for switching high currents and voltages at high power levels. This type of discharge offers the potential for improvement in essentially all areas of switching operation: peak current and current density, current rise, stand-off voltage, reverse current capability, cathode life, and forward drop. The first pseudospark switch was built at CERN at 1981. Since then, the basic switching characteristics of pseudospark chambers have been studied in detail. The main feature of a pseudospark switch is the confinement of the discharge plasma to the device axis. The current transition to the hollow electrodes is spread over a rather large surface area. Another essential feature is the easy and precise triggering of the pseudospark switch from the interior of the hollow electrodes, relatively far from the main discharge gap. Nanosecond delay and jitter values can be achieved with trigger energies of less than 0.1 mJ, although cathode heating is not required. Pseudospark gaps may cover a wide range of high-voltage, high-current, and high-pulse-power switching at repetition rates of many kilohertz. This report reviews the basic researh on pseudospark switches which has been going on at CERN. So far, applications have been developed in the range of thyratron-like medium-power switches at typically 20 to 40 kV and 0.5 to 10 kA. High-current pseudospark switches have been built for a high-power 20 kJ pulse generator which is being used for long-term tests of plasma lenses developed for the future CERN Antiproton Collector (ACOL). The high-current switches have operated for several hundred thousand shots, with 20 to 50 ns jitter at 16 kV charging voltage and more than 100 kA peak current amplitude. (orig.)

  6. Computer-assisted diagnostic procedure for multislice computed tomography for assessment of the pulmonary arterial circulation. Clinical relevance

    International Nuclear Information System (INIS)

    Malich, A.; Hentrich, D.; Hansch, A.; Teichgraeber, U.; Boettcher, J.

    2012-01-01

    A recently developed CAD software which highlights intravascular thrombotic structures from multislice computed tomography (MSCT) data was tested regarding feasibility, interobserver reliability and effect on radiology reports. The CAD system ImageChecker registered CT-Lung was tested in a randomized double-blinded study on 160 MSCT datasets (standardized technical conditions) performed for suspected pulmonary embolism (PE). The CAD data and images were analyzed by three radiologists in an independent and blinded fashion. The data from all 160 cases could be analyzed and 604 CAD prompts were set. Using the CAD analysis significantly more PEs were found in the peripheral pulmonary arterial circulation than described in the initial report. In 38 cases the 3 radiologists in consensus scored the images with the CAD adjunct as PE positive in peripheral vessels, which were initially reported as negative. Despite differences in the evaluation between two radiologists the amended assessment of the imaging data using the CAD softwear was reliable. There was a significant correlation between D-dimer values and the number of embolic structures detected by the CAD analysis. The recently developed CAD system is a useful adjunct as second reader to detect subtle emboli in peripheral vessels of MSCT datasets. (orig.) [de

  7. Recent developments in switching theory

    CERN Document Server

    Mukhopadhyay, Amar

    2013-01-01

    Electrical Science Series: Recent Developments in Switching Theory covers the progress in the study of the switching theory. The book discusses the simplified proof of Post's theorem on completeness of logic primitives; the role of feedback in combinational switching circuits; and the systematic procedure for the design of Lupanov decoding networks. The text also describes the classical results on counting theorems and their application to the classification of switching functions under different notions of equivalence, including linear and affine equivalences. The development of abstract har

  8. Pooled analysis of the CONFIRM registries: impact of gender on procedure and angiographic outcomes in patients undergoing orbital atherectomy for peripheral artery disease.

    Science.gov (United States)

    Lee, Michael S; Canan, Timothy; Rha, Seung-Woon; Mustapha, Jihad; Adams, George L

    2015-02-01

    To compare the acute procedure and angiographic outcomes of peripheral artery disease (PAD) patients treated with orbital atherectomy stratified by gender. The CONFIRM I, II, and III registries are US multicenter, nonrandomized, all-comers registries of PAD patients who were treated with orbital atherectomy. All patients with gender specified in the registry database were included in the current analysis, which compared the final residual stenosis achieved after atherectomy and the rate of acute complications in female and male patients. The 3 registries included 3131 patients with 4761 lesions: 1261 women (mean age 73.2 ± 10.7 years) with 1874 lesions and 1870 men (mean age 70.4 ± 10.2) with 2887 lesions. The women were older (p atherectomy in both men and women; however, women had a higher rate of dissection (all types). This difference is likely because of the older age and higher percentage of critical limb ischemia in women in this cohort. These results, however, suggest that additional studies should be completed to further understand the increased risks for women vs. men during endovascular procedures. © The Author(s) 2015.

  9. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    Energy Technology Data Exchange (ETDEWEB)

    D' Ercole, Loredana, E-mail: l.dercole@smatteo.pv.it [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Quaretti, Pietro; Cionfoli, Nicola [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Klersy, Catherine [Fondazione IRCCS Policlinico San Matteo, Biometry and Clinical Epidemiology Service, Research Department, (Italy); Bocchiola, Milena [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Rodolico, Giuseppe; Azzaretti, Andrea [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Lisciandro, Francesco [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Cascella, Tommaso; Zappoli Thyrion, Federico [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy)

    2013-04-15

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  10. Conservative two-step procedure including uterine artery embolization with embosphere and surgical myomectomy for the treatment of multiple fibroids: Preliminary experience

    International Nuclear Information System (INIS)

    Malartic, Cécile; Morel, Olivier; Fargeaudou, Yann; Le Dref, Olivier; Fazel, Afchine; Barranger, Emmanuel; Soyer, Philippe

    2012-01-01

    Objective: To evaluate the feasibility and safety of combined uterine artery embolization (UAE) using embosphere and surgical myomectomy as an alternative to radical hysterectomy in premenopausal women with multiple fibroids. Materials and methods: Mid-term clinical outcome (mean, 25 months) of 12 premenopausal women (mean age, 38 years) with multiple and large symptomatic fibroids who desired to retain their uterus and who were treated using combined UAE and surgical myomectomy were retrospectively analyzed. In all women, UAE alone was contraindicated because of large (>10 cm) or subserosal or submucosal fibroids and myomectomy alone was contraindicated because of too many (>10) fibroids. Results: UAE and surgical myomectomy were successfully performed in all women. Myomectomy was performed using laparoscopy (n = 6), open laparotomy (n = 3), hysteroscopy (n = 2), or laparoscopy and hysteroscopy (n = 1). Mean serum hemoglobin level drop was 0.97 g/dL and no blood transfusion was needed. No immediate complications were observed and all women reported resumption of normal menses. During a mean follow-up period of 25 months (range, 14–37 months), complete resolution of initial symptoms along with decrease in uterine volume (mean, 48%) was observed in all women. No further hysterectomy was required in any woman. Conclusion: In premenopausal women with multiple fibroids, the two-step procedure is safe and effective alternative to radical hysterectomy, which allows preserving the uterus. Further prospective studies, however, should be done to determine the actual benefit of this combined approach on the incidence of subsequent pregnancies.

  11. Real-World Switching to Riociguat: Management and Practicalities in Patients with PAH and CTEPH.

    Science.gov (United States)

    Gall, Henning; Vachiéry, Jean-Luc; Tanabe, Nobuhiro; Halank, Michael; Orozco-Levi, Mauricio; Mielniczuk, Lisa; Chang, MiKyung; Vogtländer, Kai; Grünig, Ekkehard

    2018-06-01

    A proportion of patients with pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH) do not achieve treatment goals or experience side effects on their current therapy. In such cases, switching patients to a new drug while discontinuing the first may be a viable and appropriate treatment option. CAPTURE was designed to investigate how physicians manage the switching of patients to riociguat in real-world clinical practice. Observations from the study were used to assess whether recommendations in the riociguat prescribing information are reflected in clinical practice. CAPTURE was an international, multicenter, uncontrolled, retrospective chart review that collected data from patients with PAH or inoperable or persistent/recurrent CTEPH who switched to riociguat from another pulmonary hypertension (PH)-targeted medical therapy. The primary objective of the study was to understand the procedure undertaken in real-world clinical practice for patients switching to riociguat. Of 127 patients screened, 125 were enrolled in CAPTURE. The majority of patients switched from a phosphodiesterase type 5 inhibitor (PDE5i) to riociguat and the most common reason for switching was lack of efficacy. Physicians were already using the recommended treatment-free period when switching patients to riociguat from sildenafil, but a slightly longer period than recommended for tadalafil. In line with the contraindication, the majority of patients did not receive riociguat and PDE5i therapy concomitantly. Physicians also followed the recommended dose-adjustment procedure for riociguat. Switching to riociguat from another PH-targeted therapy may be feasible in real-world clinical practice in the context of the current recommendations.

  12. Switching Phenomena

    Science.gov (United States)

    Stanley, H. E.; Buldyrev, S. V.; Franzese, G.; Havlin, S.; Mallamace, F.; Mazza, M. G.; Kumar, P.; Plerou, V.; Preis, T.; Stokely, K.; Xu, L.

    One challenge of biology, medicine, and economics is that the systems treated by these serious scientific disciplines can suddenly "switch" from one behavior to another, even though they possess no perfect metronome in time. As if by magic, out of nothing but randomness one finds remarkably fine-tuned processes in time. The past century has, philosophically, been concerned with placing aside the human tendency to see the universe as a fine-tuned machine. Here we will address the challenge of uncovering how, through randomness (albeit, as we shall see, strongly correlated randomness), one can arrive at some of the many temporal patterns in physics, economics, and medicine and even begin to characterize the switching phenomena that enable a system to pass from one state to another. We discuss some applications of correlated randomness to understanding switching phenomena in various fields. Specifically, we present evidence from experiments and from computer simulations supporting the hypothesis that water's anomalies are related to a switching point (which is not unlike the "tipping point" immortalized by Malcolm Gladwell), and that the bubbles in economic phenomena that occur on all scales are not "outliers" (another Gladwell immortalization).

  13. Anatomical Variations of the Vertebral Artery in the Upper Cervical Spine: Clinical Relevance for Procedures Targeting the C1/C2 and C2/C3 Joints.

    Science.gov (United States)

    Elgueta, Maria Francisca; Ortiz Jimenez, Johanna; Wang, Nina Nan; Pérez Lara, Almudena; Chankowsky, Jeffrey; Charghi, Roshanak; Tran, De Q; Finlayson, Roderick J

    2018-05-01

    Accidental breach of the vertebral artery (VA) during the performance of cervical pain blocks can result in significant morbidity. Whereas anatomical variations have been described for the foraminal (V2) segment of the VA, those involving its V3 portion (between the C2 transverse process and dura) have not been investigated and may be of importance for procedures targeting the third occipital nerve or the lateral atlantoaxial joint. Five hundred computed tomography angiograms of the neck performed in patients older than 50 years for the management of cerebrovascular accident or cervical trauma (between January 2010 and May 2016) were retrospectively and independently reviewed by 2 neuroradiologists. Courses of the VA in relation to the lateral aspect of the C2/C3 joint and the posterior surface of the C1/C2 joint were examined. For the latter, any medial encroachment of the VA (or one of its branches) was noted. The presence of a VA loop between C1 and C2 and its distance from the upper border of the superior articular process (SAP) of C3 were also recorded. If the VA loop coursed posteriorly, its position in relation to 6 fields found on the lateral aspects of the articular pillars of C2 and C3 was tabulated. At the C1/C2 level, the VA coursed medially over the lateral quarter of the dorsal joint surface in 1% of subjects (0.6% and 0.4% on the left and right sides, respectively; P = 0.998). A VA loop originating between C1 and C2 was found to travel posteroinferiorly over the anterolateral aspect of the inferior articular pillar of C2 in 55.5% of patients on the left and 41.9% on the right side (P < 0.001), as well as over the SAP of C3 in 0.4% of subjects. When present in the quadrant immediately cephalad to the C3 SAP, VA loops coursed within 2.0 ± 1.5 and 3.3 ± 2.5 mm on the left and right sides, respectively, of its superior aspect (P < 0.001). The VA commonly travels adjacent to areas targeted by third occipital nerve procedures and more rarely over the

  14. The Usefulness of Three-Dimensional Angiography with a Flat Panel Detector of Direct Conversion Type in a Transcatheter Arterial Chemoembolization Procedure for Hepatocellular Carcinoma: Initial Experience

    International Nuclear Information System (INIS)

    Kakeda, Shingo; Korogi, Yukunori; Hatakeyama, Yoshihisa; Ohnari, Norihiro; Oda, Nobuhiro; Nishino, Kazuyoshi; Miyamoto, Wataru

    2008-01-01

    The purpose of this study was to assess the usefulness of a three-dimensional (3D) angiography system using a flat panel detector of direct conversion type in treatments with subsegmental transcatheter arterial chemoembolization (TACE) for hepatocellular carcinomas (HCCs). Thirty-six consecutive patients who underwent hepatic angiography were prospectively examined. First, two radiologists evaluated the degree of visualization of the peripheral branches of the hepatic arteries on 3D digital subtraction angiography (DSA). Then the radiologists evaluated the visualization of tumor staining and feeding arteries in 25 patients (30 HCCs) who underwent subsegmental TACE. The two radiologists who performed the TACE assessed whether the additional information provided by 3D DSA was useful for treatments. In 34 (94.4%) of 36 patients, the subsegmental branches of the hepatic arteries were sufficiently visualized. The feeding arteries of HCCs were sufficiently visualized in 28 (93%) of 30 HCCs, whereas tumor stains were sufficiently visualized in 18 (60%). Maximum intensity projection images were significantly superior to volume recording images for visualization of the tumor staining and feeding arteries of HCCs. In 27 (90%) of 30 HCCs, 3D DSA provided additional useful information for subsegmental TACE. The high-quality 3D DSA with flat panel detector angiography system provided a precise vascular road map, which was useful for performing subsegmental TACE .of HCCs

  15. Qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins; Qualifizierungsleitlinie der Deutschen Roentgengesellschaft (DRG) und der Deutschen Gesellschaft fuer Interventionelle Radiologie und minimalinvasive Therapie (DeGIR) zur Durchfuehrung interventionell-radiologischer minimalinvasiver Verfahren an Arterien und Venen

    Energy Technology Data Exchange (ETDEWEB)

    Buecker, A. [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany); Gross-Fengels, W. [Asklepiosklinik, Hamburg-Harburg (Germany); Haage, P. [Helios-Kliniken, Wuppertal (Germany); Huppert, P. [Klinikum Darmstadt (Germany); Landwehr, P. [Henriettenstiftung, Hannover (Germany); Loose, R. [Klinikum Nuernberg-Nord (Germany); Reimer, P. [Klinikum Karlsruhe (Germany); Tacke, J. [Klinikum Passau (Germany); Vorwerk, D. [Klinikum Ingolstadt (Germany); Fischer, J.

    2012-06-15

    The topics covered in the qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins are the following: Practical qualification: aorta iliac vessels and vessels in the upper and lower extremities, kidney and visceral arteries, head and neck arteries, dialysis shunts, veins and pulmonary arteries, aorta aneurysms and peripheral artery aneurysms. Knowledge acquisition concerning radiation protection: legal fundamentals, education and training, knowledge actualization and quality control, definition of the user and the procedure, competence preservation.

  16. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...

  17. Anomalous right coronary artery arising from the pulmonary artery and constrictive pericarditis: an unusual association

    Science.gov (United States)

    Silvestre, Odilson Marcos; Adam, Eduardo Leal; de Melo, Dirceu Thiago Pessoa; Dias, Ricardo Ribeiro; Ramires, Felix J. A.; Mady, Charles

    2013-01-01

    ABSTRACT The association of anomalous right coronary artery originating from the pulmonary artery and constrictive pericarditis has never been showed in the literature. We present the first case of this unusual association in a patient with right heart failure. After diagnosis, the patient was referred to surgery and underwent phrenic-to-phrenic pericardiectomy; graft implant of right internal thoracic artery to right coronary artery; and ligation of the anomalous origin of the right coronary artery from the pulmonary artery. Such procedures solved the potential risk of sudden death related to anomalous right coronary artery originating from the pulmonary artery and alleviated the symptoms of heart failure caused by constrictive pericarditis. PMID:24136766

  18. Massive cerebral arterial air embolism following arterial catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.W. [Northwestem University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Yang, B.P. [Northwestern University Feinberg School of Medicine, Department of Neurological Surgery, Chicago, IL (United States)

    2005-12-01

    Microscopic cerebral arterial air embolism (CAAE) has been described in many patients undergoing cardiac surgery as well as other invasive diagnostic and therapeutic procedures. However, massive CAAE is rare. We report a 42-year-old woman who initially presented with thalamic and basal ganglia hemorrhages. Shortly after a radial arterial catheter was inserted, the patient suffered a generalized seizure and CT demonstrated intra-arterial air in bilateral cerebral hemispheres. (orig.)

  19. Directional atherectomy facilitates the interventional procedure and leads to a low rate of recurrent stenosis in left anterior descending and left circumflex artery ostium stenoses: subgroup analysis of the FLEXI‐CUT study

    Science.gov (United States)

    Dahm, J B; Ruppert, J; Hartmann, S; Vogelgesang, D; Hummel, A; Felix, S B

    2006-01-01

    Objectives To examine by retrospective analysis of data from the FLEXI‐CUT monocentre registry whether atherectomy can effectively simplify complex stent implantation in ostial bifurcation lesions by reducing the procedure to stenting of the left anterior descending (LAD) or left circumflex (LCX) artery ostium alone. Patients and methods All patients who had been enrolled in the prospective FLEXI‐CUT study (directional atherectomy with adjunctive balloon angioplasty) were retrospectively analysed on the basis of significant LAD or LCX ostial stenosis (⩾ 70% stenosis) deriving from an undiseased left main stem. The primary combined end point was the rate of target lesion revascularisation (TLR) and binary restenosis; secondary end points were procedural success and major adverse cardiac events (MACE) at the six‐month follow up. Results Of 30 patients enrolled with significant LAD or LCX ostium stenosis, 29 were effectively treated with directional atherectomy (96.7% procedural success). All patients underwent single‐vessel stenting procedures of solely the LAD or LCX ostium. At follow up, binary stenosis was 25% (6 of 24), TLR (angiographic plus clinical) 10.3% (3 of 29) and total MACE 6.9% (2 of 29). Conclusions Directional atherectomy with single‐vessel stenting procedures facilitates the interventional treatment of LAD and LCX ostium stenosis, and leads to remarkably low TLR and binary stenosis at follow up. PMID:16449510

  20. Switched on!

    CERN Multimedia

    2008-01-01

    Like a star arriving on stage, impatiently followed by each member of CERN personnel and by millions of eyes around the world, the first beam of protons has circulated in the LHC. After years in the making and months of increasing anticipation, today the work of hundreds of people has borne fruit. WELL DONE to all! Successfully steered around the 27 kilometres of the world’s most powerful particle accelerator at 10:28 this morning, this first beam of protons circulating in the ring marks a key moment in the transition from over two decades of preparation to a new era of scientific discovery. "It’s a fantastic moment," said the LHC project leader Lyn Evans, "we can now look forward to a new era of understanding about the origins and evolution of the universe". Starting up a major new particle accelerator takes much more than flipping a switch. Thousands of individual elements have to work in harmony, timings have to be synchronize...

  1. Giant true celiac artery aneurysm

    International Nuclear Information System (INIS)

    Aljabri, Badr

    2009-01-01

    Celiac artery aneurysms are rare and usually asymptomatic. The management of these aneurysms is challenging, especially when they are large and involve the confluence of the trifurcation. We present here a case of a large celiac artery aneurysm involving its branches in a young woman. Preoperative investigations, intraoperative findings, and the operative procedure are also presented and discussed. (author

  2. Immediate effects of isolated transmyocardial laser revascularization procedures combined with intramyocardial injection of autologous bone marrow stem cells in patients with terminal stage of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Leo A. Bockeria

    2017-05-01

    Conclusions ― TMLR with intramyocardial autologous stem cells injections in patients with end-stage CAD is safe. This procedure can be done in the most severe group of patients who cannot be completely revascularized with either PCI or CABG surgery. Futher investigation is needed to assess the effectiveness of the procedure.

  3. Digital switched hydraulics

    Science.gov (United States)

    Pan, Min; Plummer, Andrew

    2018-06-01

    This paper reviews recent developments in digital switched hydraulics particularly the switched inertance hydraulic systems (SIHSs). The performance of SIHSs is presented in brief with a discussion of several possible configurations and control strategies. The soft switching technology and high-speed switching valve design techniques are discussed. Challenges and recommendations are given based on the current research achievements.

  4. Endovascular uterine artery interventions

    Directory of Open Access Journals (Sweden)

    Chandan J Das

    2017-01-01

    Full Text Available Percutaneous vascular embolization plays an important role in the management of various gynecologic and obstetric abnormalities. Transcatheter embolization is a minimally invasive alternative procedure to surgery with reduced morbidity and mortality, and preserves the patient's future fertility potential. The clinical indications for transcatheter embolization are much broader and include many benign gynecologic conditions, such as fibroid, adenomyosis, and arteriovenous malformations (AVMs, as well as intractable bleeding due to inoperable advanced-stage malignancies. The most well-known and well-studied indication is uterine fibroid embolization. Uterine artery embolization (UAE may be performed to prevent or treat bleeding associated with various obstetric conditions, including postpartum hemorrhage (PPH, placental implantation abnormality, and ectopic pregnancy. Embolization of the uterine artery or the internal iliac artery also may be performed to control pelvic bleeding due to coagulopathy or iatrogenic injury. This article discusses these gynecologic and obstetric indications for transcatheter embolization and reviews procedural techniques and outcomes.

  5. Management strategies for thoracic stent-graft repair of distal aortic arch lesions: is intentional subclavian artery occlusion a safe procedure?

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio; Salvatori, Filippo Maria; Pucci, Armando; Lucatelli, Pierleone; Rossi, Plinio; Passariello, Roberto [University of Rome La Sapienza, Department of Radiological Sciences, Rome (Italy); Dake, Michael D. [Stanford University School of Medicine, Department of Cardiothoracic Surgery Radiology, Stanford, CA (United States); Mazzesi, Giuseppe [University of Rome La Sapienza, Institute of Heart and Great Vessels, Rome (Italy)

    2009-10-15

    The aim of this retrospective analysis was to assess the clinical consequences after intentional left subclavian artery (LSA) occlusion. Thirty-seven patients, 27 type B dissection and 10 thoracic aneurysm, with short proximal neck (less than 2 cm) underwent endovascular treatment with intentional exclusion of LSA origin. No immediate complications occurred. Mean arterial pressure gradient, between right and left arms, ranged from 15 to 45 mmHg. After a mean follow-up of 43.70{+-}24.01 months, mild left arm symptoms secondary to flow reduction occurred in eight cases (21.6%) but only one required LSA transposition, after 8 months, for visual impairment. Type II endoleaks from excluded LSA occurred in 10 cases (27.0%): in seven patients, leaks were treated with coils and/or glue embolization; in one case, leak sealed spontaneously; one patient died before leak embolization could occur; one patient refused any further treatment. Intentional exclusion of the LSA may be justified when a longer proximal landing zone in the aortic arch is required. (orig.)

  6. Incidence and outcome of surgical procedures after coronary artery bypass grafting compared with those after percutaneous coronary intervention: a report from the Coronary Revascularization Demonstrating Outcome Study in Kyoto PCI/CABG Registry Cohort-2.

    Science.gov (United States)

    Tokushige, Akihiro; Shiomi, Hiroki; Morimoto, Takeshi; Ono, Koh; Furukawa, Yutaka; Nakagawa, Yoshihisa; Kadota, Kazushige; Ando, Kenji; Shizuta, Satoshi; Tada, Tomohisa; Tazaki, Junichi; Kato, Yoshihiro; Hayano, Mamoru; Abe, Mitsuru; Hamasaki, Shuichi; Ohishi, Mitsuru; Nakashima, Hitoshi; Mitsudo, Kazuaki; Nobuyoshi, Masakiyo; Kita, Toru; Imoto, Yutaka; Sakata, Ryuzo; Okabayashi, Hitoshi; Hanyu, Michiya; Shimamoto, Mitsuomi; Nishiwaki, Noboru; Komiya, Tatsuhiko; Kimura, Takeshi

    2014-08-01

    Noncardiac surgery after percutaneous coronary intervention (PCI) has been reported to be carrying high risk for both ischemic and bleeding complications. However, there has been no report comparing the incidence and outcomes of surgical procedures after coronary artery bypass grafting (CABG) with those after PCI. Among 14 383 patients undergoing first coronary revascularization (PCI, n=12 207; CABG, n=2176) enrolled in the Coronary Revascularization Demonstrating Outcome Study in Kyoto (CREDO-Kyoto) PCI/CABG Registry Cohort-2, surgical procedures were performed more frequently after CABG (n=560) than after PCI (n=2398; cumulative 3-year incidence: 27% versus 22%; unadjusted PPCI groups (cumulative incidence: 3.1% versus 3.2%; unadjusted P=0.9; adjusted hazard ratio, 0.97; 95% confidence interval, 0.47-1.89; P=0.9). The risk for the primary bleeding outcome measure (moderate or severe bleeding by Global Utilization of Streptokinase and Tissue Plasminogen Activator for Occluded Coronary Arteries classification) was lower in the CABG groups than in the PCI group (cumulative incidence: 1.3% versus 2.6%; unadjusted P=0.07; adjusted hazard ratio, 0.36; 95% confidence interval, 0.12-0.87; P=0.02). There were no interactions between the timing of surgery and the types of coronary revascularization (CABG/PCI) for both ischemic and bleeding outcomes. Surgical procedures were performed significantly more frequently after CABG than after PCI, particularly PCI were associated with similar risk for ischemic events and lower risk for bleeding events, regardless of the timing after coronary revascularization. © 2014 American Heart Association, Inc.

  7. Pressão arterial do anestesiologista durante o ato anestésico-cirúrgico no período matutino Presión arterial del anestesista durante el acto anestésico-quirúrgico en el período matutino Anesthesiologists’ blood pressure during surgical anesthetic procedures in the morning

    Directory of Open Access Journals (Sweden)

    Pedro Wanderley de Aragão

    2002-09-01

    estudio fue verificar si la práctica de la anestesia es factor desencadenante de la variación de la presión arterial en el anestesista durante el acto anestésico quirúrgico. MÉTODO: Participaron del estudio diez anestesistas, cada un realizando diez anestesias raquidianas para parto cesariano. Fueron registradas cinco medidas de la presión arterial en cinco momentos diferentes, en el total de 50 afericiones por anestesista. La primera, realizada después de descanso previo de cinco minutos de la llegada del anestesista al centro quirúrgico, denominado M1. La segunda, antes de la realización de la punción lumbar, M2. La tercera, luego después de la retirada de la aguja del local de la punción donde fue realizado el bloqueo, M3. La cuarta, inmediatamente después de la retirada del feto, M4. Y la última aferición, al término de la sutura de la piel. M5. RESULTADOS: Ocurrió elevación en la presión arterial del anestesista nos momentos M3 y M4. CONCLUSIONES: La práctica anestésica realizada es responsable por la alteración significativa de la presión arterial del anestesista y está directamente relacionada con los momentos de mayor riesgo para el paciente durante el acto anestésico quirúrgico.BACKGROUND AND OBJECTIVES: Systemic arterial hypertension affects approximately 20% of the world population, depending on the interaction between genetic predisposition and environmental factors. Stresses inherent to the anesthesiologist’s work might reflect in the cardiovascular system, influencing professional’s blood pressure. This study aimed at verifying whether the practice of anesthesia is a triggering factor for anesthesiologists’ blood pressure changes during surgical anesthetic procedures. METHODS: Participated in these study 10 anesthesiologists, each one inducing 10 spinal anesthesias for cesarean section. Blood pressure was measured in five different moments, in a total of 50 readings one each anesthesiologist. The first measure was recorded

  8. Duplication of the Left Vertebral Artery Origin: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sang Wook; Park, Dong Woo; Park, Choong Ki; Lee, Young Jun [Dept. of Radiology, College of Medicine, Hanyang University, Hanyang University Guri Hospital, Guri (Korea, Republic of)

    2013-01-15

    Duplication of vertebral arteries is a very rare but clinically important condition. A duplicated vertebral artery origin can influence hemodynamics, pathogenesis of vascular lesions and treatment options. In cases of vertebral artery duplication, the vertebral arteries generally enter the transverse foramen higher up than normal. Awareness of these vertebral artery variants before procedures, such as neurointervention or surgery, may be beneficial. Here, we describe a case of a 51-year-old female patient with left vertebral artery duplication which was detected incidentally.

  9. Duplication of the Left Vertebral Artery Origin: A Case Report

    International Nuclear Information System (INIS)

    Shin, Sang Wook; Park, Dong Woo; Park, Choong Ki; Lee, Young Jun

    2013-01-01

    Duplication of vertebral arteries is a very rare but clinically important condition. A duplicated vertebral artery origin can influence hemodynamics, pathogenesis of vascular lesions and treatment options. In cases of vertebral artery duplication, the vertebral arteries generally enter the transverse foramen higher up than normal. Awareness of these vertebral artery variants before procedures, such as neurointervention or surgery, may be beneficial. Here, we describe a case of a 51-year-old female patient with left vertebral artery duplication which was detected incidentally.

  10. Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

    International Nuclear Information System (INIS)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis; Padayachee, Soundrie; Karunanithy, Narayan; Ahmed, Irfan; Zayed, Hany; Katsanos, Konstantinos

    2015-01-01

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery

  11. Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Padayachee, Soundrie [King’s Health Partners, Department of Ultrasonic Angiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Karunanithy, Narayan; Ahmed, Irfan [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Zayed, Hany [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: konstantinos.katsanos@gstt.nhs.uk, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery.

  12. Starclose SE® hemostasis after 6F direct antegrade superficial femoral artery access distal to the femoral head for peripheral endovascular procedures in obese patients.

    Science.gov (United States)

    Spiliopoulos, Stavros; Kitrou, Panagiotis; Christeas, Nikolaos; Karnabatidis, Dimitris

    2016-01-01

    Direct superficial femoral artery (SFA) antegrade puncture is a valid alternative to common femoral artery (CFA) access for peripheral vascular interventions. Data investigating vascular closure device (VCD) hemostasis of distant SFA 6F access are limited. We aimed to investigate the safety and effectiveness of the Starclose SE® VCD for hemostasis, following direct 6F antegrade SFA access distal to the femoral head. This prospective, single-center study included patients who were not suitable for CFA puncture and were scheduled to undergo peripheral endovascular interventions using direct antegrade SFA 6F access, at least 2 cm below the inferior edge of femoral head. Hemostasis was obtained with the Starclose SE® VCD (Abbott Laboratories). Primary endpoints were successful hemostasis rate and periprocedural (30-day) major complication rate. Secondary endpoint was the rate of minor complications. Clinical and Doppler ultrasound follow-up was performed at discharge and at one month. Between September 2014 and August 2015, a total of 30 patients (21 male; 70.0%) with a mean body mass index of 41.2 kg/m2 were enrolled. Mean age was 72±9 years (range, 67-88 years). Most patients suffered from critical limb ischemia (87.1%) and diabetes (61.3%). Calcifications were present in eight cases (26.6%). Reason for direct SFA puncture was obesity (100%). Successful hemostasis was achieved in 100% of the cases. No major complications were noted after one-month follow-up. Minor complications included two <5 cm hematomas (6.6%) not necessitating treatment. In this prospective study, Starclose SE® VCD was safe and effective for hemostasis of antegrade direct SFA puncture. Uncomplicated hemostasis was achieved even in cases of puncturing 2 to 7 cm below the inferior edge of the femoral head.

  13. High efficiency three-phase power factor correction rectifier using SiC switches

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Nymand, Morten

    2017-01-01

    This paper presents designing procedure of a high efficiency 5 kW silicon-carbide (SiC) based threephase power factor correction (PFC). SiC switches present low capacitive switching loss compared to the alternative Si switches. Therefore, the switching frequency can be increased and hence the siz...

  14. Latching micro optical switch

    Science.gov (United States)

    Garcia, Ernest J; Polosky, Marc A

    2013-05-21

    An optical switch reliably maintains its on or off state even when subjected to environments where the switch is bumped or otherwise moved. In addition, the optical switch maintains its on or off state indefinitely without requiring external power. External power is used only to transition the switch from one state to the other. The optical switch is configured with a fixed optical fiber and a movable optical fiber. The movable optical fiber is guided by various actuators in conjunction with a latching mechanism that configure the switch in one position that corresponds to the on state and in another position that corresponds to the off state.

  15. Comparison of switching control algorithms effective in restricting the switching in the neighborhood of the origin

    International Nuclear Information System (INIS)

    Joung, JinWook; Chung, Lan; Smyth, Andrew W

    2010-01-01

    The active interaction control (AIC) system consisting of a primary structure, an auxiliary structure and an interaction element was proposed to protect the primary structure against earthquakes and winds. The objective of the AIC system in reducing the responses of the primary structure is fulfilled by activating or deactivating the switching between the engagement and the disengagement of the primary and auxiliary structures through the interaction element. The status of the interaction element is controlled by switching control algorithms. The previously developed switching control algorithms require an excessive amount of switching, which is inefficient. In this paper, the excessive amount of switching is restricted by imposing an appropriately designed switching boundary region, where switching is prohibited, on pre-designed engagement–disengagement conditions. Two different approaches are used in designing the newly proposed AID-off and AID-off 2 algorithms. The AID-off 2 algorithm is designed to affect deactivated switching regions explicitly, unlike the AID-off algorithm, which follows the same procedure of designing the engagement–disengagement conditions of the previously developed algorithms, by using the current status of the AIC system. Both algorithms are shown to be effective in reducing the amount of switching times triggered from the previously developed AID algorithm under an appropriately selected control sampling period for different earthquakes, but the AID-off 2 algorithm outperforms the AID-off algorithm in reducing the number of switching times

  16. Cirurgia de Glenn bidirecional: importância da manutenção de fluxo "pulsátil" na artéria pulmonar Bidirectional Glenn procedure: the importance of "pulsatile" flow in the pulmonary artery

    Directory of Open Access Journals (Sweden)

    Fernando Antônio Fantini

    1995-03-01

    In order to evaluate the effects of pulsatile flow in the pulmonary artery of patients undergoing bidirectional cavopulmonary shunts (BCS, we reviewed the data of 36 patients operated upon from October 1990 to July 1994. Age at operation ranged from 11 months to 14 years (mean 4.4 ± 3.4 years and diagnoses were as follows: tricuspid atresia (18, single ventricle (16, mitral atresia (1 and pulmonary atresia with intact ventricular septum (1. A total of 19 (52.8% patients had a prior palliative operation done. Cardiopulmonary bypass was used in every case, with mild hypothermia in 11 cases and profound hypothermia and circulatory arrest in the remaining. The surgical technique was an anastomosis between the superior vena cava and the ipsilateral pulmonary artery in an end-to-side fashion. The main pulmonary artery was ligated only if the mean pressure taken at the site of the anastomosis was higher than 15 mmHg but in 2 recent cases with a very high mean pulmonary pressure, the main pulmonary artery was banded, adjusting the pressure to the desirable levels. The overall hospital survival was 91.7% (33 patients. One patient required a systemic to pulmonary shunt due to persistent low arterial oxygen saturation, 7 days after the BCS. Twenty-eight patients were followed for a mean of 1.8 ± 1.2 years (3 months to 4.1 years and were divided in 2 groups: A-18 patients without pulsatile flow in the pulmonary artery, and B-10 patients with pulsatile flow. In Group B, the mean arterial saturation has ranged from 80% to 90% (mean 86 ± 3.8% and is significantly higher than in Group A (68 to 85%, mean, 77.6 ± 5.5 (p<0.001. Two patients of Group A are in NYHA functional class III, whereas all patients of Group B are in class I or II (p=0.05. There was one late death and one patient required a subsequent Fontan procedure, both of Group A. Thus, the presence of pulsatile flow in the pulmonary artery improved the arterial oxigen saturation and exercise tolerance in patients submitted to

  17. Incorrect predictions reduce switch costs.

    Science.gov (United States)

    Kleinsorge, Thomas; Scheil, Juliane

    2015-07-01

    In three experiments, we combined two sources of conflict within a modified task-switching procedure. The first source of conflict was the one inherent in any task switching situation, namely the conflict between a task set activated by the recent performance of another task and the task set needed to perform the actually relevant task. The second source of conflict was induced by requiring participants to guess aspects of the upcoming task (Exps. 1 & 2: task identity; Exp. 3: position of task precue). In case of an incorrect guess, a conflict accrues between the representation of the guessed task and the actually relevant task. In Experiments 1 and 2, incorrect guesses led to an overall increase of reaction times and error rates, but they reduced task switch costs compared to conditions in which participants predicted the correct task. In Experiment 3, incorrect guesses resulted in faster performance overall and to a selective decrease of reaction times in task switch trials when the cue-target interval was long. We interpret these findings in terms of an enhanced level of controlled processing induced by a combination of two sources of conflict converging upon the same target of cognitive control. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Artery ligation in the treatment of hemorrhoidal disease

    NARCIS (Netherlands)

    Schuurman, J.P.

    2012-01-01

    The aim of this thesis was to study the working principle in relation to the outcome of the artery ligation procedure; a treatment for hemorrhoidal disease. Hemorrhoidal artery ligation, known as HAL (hemorrhoidal artery ligation) or THD (transanal hemorrhoidal dearterialization) procedure, is a

  19. Cervicocephalic arterial dissection

    International Nuclear Information System (INIS)

    Suyama, Kazuhiko; Hayashi, Kentaro; Nagata, Izumi

    2008-01-01

    The authors review the clinical and neuroradiological features of cervicocephalic arterial dissection, which is occasionally seen in young adults, with special reference to the differences in the region of occurrence of these lesions between patients in Western countries and Japan. In Western countries, the cervical internal carotid artery is the most common site of occurrence of these lesions; however, in Japan, these lesions have been frequently reported to occure in the intracranial vertebral artery. Most clinical manifestations of cervical arterial dissection are non-hemorrhagic events such as headaches associated with arterial dissection or cerebral ischemia caused by a distal embolism following thrombus formation in the cervical lesion. On the other hand, a subarachnoid hemorrhage and cerebral infarction are frequently observed in intracranial arterial dissections. Non-invasive procedures, including MR imaging, are useful for demonstrating characteristic features of this condition such as the presence of an intimal flap or a double lumen, and for monitoring the chronological changes in the lesions, which may regress spontaneously. Since the pathological mechanisms underlying the progression and/or the regression of this condition are still unknown, the clinical evidence indicating the optimal therapeutic strategies has not yet been reported. Nevertheless, conservative therapy, including antithrombotic treatment, is widely used for the treatment of non-hemorrhagic lesions, which generally results in good clinical outcomes. Further, surgical intervention is essential for the treatment of lesions with a subarachnoid hemorrhage to prevent fatal rebleeding, and it is also required for the treatment of certain non-hemorrhagic lesions. Recent advancements in surgical procedures, especially endovascular treatments, may therefore be helpful in the management of similar complicated vascular conditions. (author)

  20. Interventional treatment of transplanted renal artery stenosis

    International Nuclear Information System (INIS)

    Zhou Haihong; Chen Weiguo; Lu Wei; Chen Yong; Yan Xinmin; Zhou Jianyong; Li Yanhao

    2002-01-01

    Purpose: To evaluate the clinical application of percutaneous transluminal renal artery angioplasty (PTRA) in the treatment of transplanted renal artery stenosis. Methods: Nine patients with transplanted renal artery stenosis were treated by PTRA with balloon catheter through the f amoral artery. Metal stent was placed in 3 patients out of 9. Results: Technical success was obtained in all procedures. In 7 patients normal blood pressure was restored and serum creatinine remarkably decreased. But anti-hypertension drugs were still needed in rest 2 patients. Conclusion: PTRA and stent implantation are useful and valuable method in the treatment of transplanted renal artery stenosis

  1. Arterial stick

    Science.gov (United States)

    ... be some throbbing. Why the Test Is Performed Blood transports oxygen, nutrients, waste products, and other materials within ... venous blood) mainly in its content of dissolved gases . Testing arterial blood shows the makeup of the blood before any ...

  2. Transposition of the great arteries

    Directory of Open Access Journals (Sweden)

    Castela Eduardo

    2008-10-01

    required soon after birth. Surgical correction is performed at a later stage. Usually, the Jatene arterial switch operation is the procedure of choice. Whenever this operation is not feasible, adequate alternative surgical approach should be implemented. With the advent of newer and improved surgical techniques and post operative intensive care, the long-term survival is approximately 90% at 15 years of age. However, the exercise performance, cognitive function and quality of life may be impaired.

  3. Inferior phrenic artery embolization in the treatment of hepatic neoplasms

    International Nuclear Information System (INIS)

    Duprat, G.; Charnsangavej, C.; Wallace, S.; Carrasco, C.H.

    1988-01-01

    Twenty-nine inferior phrenic artery embolizations were performed in 20 patients with primary or metastatic hepatic neoplasms. All patients had interruption of their hepatic arteries by previous infusion of chemotherapy, hepatic arterial embolization or surgical ligation. In one patient, bilateral pleural effusions developed following embolization of the inferior phrenic artery. No other severe complications occurred. Inferior phrenic artery embolization is a safe procedure and permits the continuation of transcatheter treatment of hepatic neoplasms. (orig.)

  4. Inferior phrenic artery embolization in the treatment of hepatic neoplasms

    Energy Technology Data Exchange (ETDEWEB)

    Duprat, G.; Charnsangavej, C.; Wallace, S.; Carrasco, C.H.

    Twenty-nine inferior phrenic artery embolizations were performed in 20 patients with primary or metastatic hepatic neoplasms. All patients had interruption of their hepatic arteries by previous infusion of chemotherapy, hepatic arterial embolization or surgical ligation. In one patient, bilateral pleural effusions developed following embolization of the inferior phrenic artery. No other severe complications occurred. Inferior phrenic artery embolization is a safe procedure and permits the continuation of transcatheter treatment of hepatic neoplasms.

  5. The selective external carotid arterial embolization treatment of uncontrollable epistaxis

    International Nuclear Information System (INIS)

    Yao Qunli; Liu Yizhi; Ni Caifang

    2004-01-01

    Objective: To evaluate the selective external carotid arterial embolization of uncontrollable epistaxis. Methods: 27 procedures of super-selective external carotid arterial embolization were performed with absorbable gelfoam by using Seldinger's method in 26 cases with uncontrollable epistaxis. Results: 27 procedures of super-selective intra-arterial embolization of uncontrollable epistaxis were all successful without any serious complication. Conclusions: Selective external carotid arterial embolization is safe, effective and successful in the treatment of severe epistaxis. (authors)

  6. Optical packet switched networks

    DEFF Research Database (Denmark)

    Hansen, Peter Bukhave

    1999-01-01

    Optical packet switched networks are investigated with emphasis on the performance of the packet switch blocks. Initially, the network context of the optical packet switched network is described showing that a packet network will provide transparency, flexibility and bridge the granularity gap...... in interferometric wavelength converters is investigated showing that a 10 Gbit/s 19 4x4 swich blocks can be cascaded at a BER of 10-14. An analytical traffic model enables the calculation of the traffice performance of a WDM packet network. Hereby the importance of WDM and wavelegth conversion in the switch blocks...... is established as a flexible means to reduce the optical buffer, e.g., the number of fibre delay lines for a 16x16 switch block is reduced from 23 to 6 by going from 2 to 8 wavelength channels pr. inlet. Additionally, a component count analysis is carried out to illustrate the trade-offs in the switch block...

  7. Saturated Switching Systems

    CERN Document Server

    Benzaouia, Abdellah

    2012-01-01

    Saturated Switching Systems treats the problem of actuator saturation, inherent in all dynamical systems by using two approaches: positive invariance in which the controller is designed to work within a region of non-saturating linear behaviour; and saturation technique which allows saturation but guarantees asymptotic stability. The results obtained are extended from the linear systems in which they were first developed to switching systems with uncertainties, 2D switching systems, switching systems with Markovian jumping and switching systems of the Takagi-Sugeno type. The text represents a thoroughly referenced distillation of results obtained in this field during the last decade. The selected tool for analysis and design of stabilizing controllers is based on multiple Lyapunov functions and linear matrix inequalities. All the results are illustrated with numerical examples and figures many of them being modelled using MATLAB®. Saturated Switching Systems will be of interest to academic researchers in con...

  8. Effective switching frequency multiplier inverter

    Science.gov (United States)

    Su, Gui-Jia [Oak Ridge, TN; Peng, Fang Z [Okemos, MI

    2007-08-07

    A switching frequency multiplier inverter for low inductance machines that uses parallel connection of switches and each switch is independently controlled according to a pulse width modulation scheme. The effective switching frequency is multiplied by the number of switches connected in parallel while each individual switch operates within its limit of switching frequency. This technique can also be used for other power converters such as DC/DC, AC/DC converters.

  9. FreeSWITCH Cookbook

    CERN Document Server

    Minessale, Anthony

    2012-01-01

    This is a problem-solution approach to take your FreeSWITCH skills to the next level, where everything is explained in a practical way. If you are a system administrator, hobbyist, or someone who uses FreeSWITCH on a regular basis, this book is for you. Whether you are a FreeSWITCH expert or just getting started, this book will take your skills to the next level.

  10. Elements of magnetic switching

    International Nuclear Information System (INIS)

    Aaland, K.

    1983-01-01

    This chapter describes magnetic switching as a method of connecting a capacitor bank (source) to a load; reviews several successful applications of magnetic switching, and discusses switching transformers, limitations and future possibilities. Some of the inflexibility and especially the high cost of magnetic materials may be overcome with the availability of the new splash cooled ribbons (Metglas). Experience has shown that magnetics works despite shock, radiation or noise interferences

  11. Pemodelan Markov Switching Autoregressive

    OpenAIRE

    Ariyani, Fiqria Devi; Warsito, Budi; Yasin, Hasbi

    2014-01-01

    Transition from depreciation to appreciation of exchange rate is one of regime switching that ignored by classic time series model, such as ARIMA, ARCH, or GARCH. Therefore, economic variables are modeled by Markov Switching Autoregressive (MSAR) which consider the regime switching. MLE is not applicable to parameters estimation because regime is an unobservable variable. So that filtering and smoothing process are applied to see the regime probabilities of observation. Using this model, tran...

  12. Call for Papers: Photonics in Switching

    Science.gov (United States)

    Wosinska, Lena; Glick, Madeleine

    2006-04-01

    Call for Papers: Photonics in Switching Guest Editors: Lena Wosinska, Royal Institute of Technology (KTH) / ICT Sweden Madeleine Glick, Intel Research, Cambridge, UK Technologies based on DWDM systems allow data transmission with bit rates of Tbit/s on a single fiber. To facilitate this enormous transmission volume, high-capacity and high-speed network nodes become inevitable in the optical network. Wideband switching, WDM switching, optical burst switching (OBS), and optical packet switching (OPS) are promising technologies for harnessing the bandwidth of WDM optical fiber networks in a highly flexible and efficient manner. As a number of key optical component technologies approach maturity, photonics in switching is becoming an increasingly attractive and practical solution for the next-generation of optical networks. The scope of this special issue is focused on the technology and architecture of optical switching nodes, including the architectural and algorithmic aspects of high-speed optical networks. Scope of Submission The scope of the papers includes, but is not limited to, the following topics: WDM node architectures Novel device technologies enabling photonics in switching, such as optical switch fabrics, optical memory, and wavelength conversion Routing protocols WDM switching and routing Quality of service Performance measurement and evaluation Next-generation optical networks: architecture, signaling, and control Traffic measurement and field trials Optical burst and packet switching OBS/OPS node architectures Burst/Packet scheduling and routing algorithms Contention resolution/avoidance strategies Services and applications for OBS/OPS (e.g., grid networks, storage-area networks, etc.) Burst assembly and ingress traffic shaping Hybrid OBS/TDM or OBS/wavelength routing Manuscript Submission To submit to this special issue, follow the normal procedure for submission to JON and select ``Photonics in Switching' in the features indicator of the online

  13. Arterial stiffness

    Directory of Open Access Journals (Sweden)

    Ursula Quinn

    2012-09-01

    Full Text Available Measurements of biomechanical properties of arteries have become an important surrogate outcome used in epidemiological and interventional cardiovascular research. Structural and functional differences of vessels in the arterial tree result in a dampening of pulsatility and smoothing of blood flow as it progresses to capillary level. A loss of arterial elastic properties results a range of linked pathophysiological changes within the circulation including increased pulse pressure, left ventricular hypertrophy, subendocardial ischaemia, vessel endothelial dysfunction and cardiac fibrosis. With increased arterial stiffness, the microvasculature of brain and kidneys are exposed to wider pressure fluctuations and may lead to increased risk of stroke and renal failure. Stiffening of the aorta, as measured by the gold-standard technique of aortic Pulse Wave Velocity (aPWV, is independently associated with adverse cardiovascular outcomes across many different patient groups and in the general population. Therefore, use of aPWV has been proposed for early detection of vascular damage and individual cardiovascular risk evaluation and it seems certain that measurement of arterial stiffness will become increasingly important in future clinical care. In this review we will consider some of the pathophysiological processes that result from arterial stiffening, how it is measured and factors that may drive it as well as potential avenues for therapy. In the face of an ageing population where mortality from atheromatous cardiovascular disease is falling, pathology associated with arterial stiffening will assume ever greater importance. Therefore, understanding these concepts for all clinicians involved in care of patients with cardiovascular disease will become vital.

  14. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  15. Transient-Switch-Signal Suppressor

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Circuit delays transmission of switch-opening or switch-closing signal until after preset suppression time. Used to prevent transmission of undesired momentary switch signal. Basic mode of operation simple. Beginning of switch signal initiates timing sequence. If switch signal persists after preset suppression time, circuit transmits switch signal to external circuitry. If switch signal no longer present after suppression time, switch signal deemed transient, and circuit does not pass signal on to external circuitry, as though no transient switch signal. Suppression time preset at value large enough to allow for damping of underlying pressure wave or other mechanical transient.

  16. Optimal switching using coherent control

    DEFF Research Database (Denmark)

    Kristensen, Philip Trøst; Heuck, Mikkel; Mørk, Jesper

    2013-01-01

    that the switching time, in general, is not limited by the cavity lifetime. Therefore, the total energy required for switching is a more relevant figure of merit than the switching speed, and for a particular two-pulse switching scheme we use calculus of variations to optimize the switching in terms of input energy....

  17. Switched reluctance motor drives

    Indian Academy of Sciences (India)

    Davis RM, Ray WF, Blake RJ 1981 Inverter drive for switched reluctance: circuits and component ratings. Inst. Elec. Eng. Proc. B128: 126-136. Ehsani M. 1991 Position Sensor elimination technique for the switched reluctance motor drive. US Patent No. 5,072,166. Ehsani M, Ramani K R 1993 Direct control strategies based ...

  18. Manually operated coded switch

    International Nuclear Information System (INIS)

    Barnette, J.H.

    1978-01-01

    The disclosure related to a manually operated recodable coded switch in which a code may be inserted, tried and used to actuate a lever controlling an external device. After attempting a code, the switch's code wheels must be returned to their zero positions before another try is made

  19. Switch on, switch off: stiction in nanoelectromechanical switches

    KAUST Repository

    Wagner, Till J W

    2013-06-13

    We present a theoretical investigation of stiction in nanoscale electromechanical contact switches. We develop a mathematical model to describe the deflection of a cantilever beam in response to both electrostatic and van der Waals forces. Particular focus is given to the question of whether adhesive van der Waals forces cause the cantilever to remain in the \\'ON\\' state even when the electrostatic forces are removed. In contrast to previous studies, our theory accounts for deflections with large slopes (i.e. geometrically nonlinear). We solve the resulting equations numerically to study how a cantilever beam adheres to a rigid electrode: transitions between \\'free\\', \\'pinned\\' and \\'clamped\\' states are shown to be discontinuous and to exhibit significant hysteresis. Our findings are compared to previous results from linearized models and the implications for nanoelectromechanical cantilever switch design are discussed. © 2013 IOP Publishing Ltd.

  20. Renal artery pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Luiz Inácio Roman

    Full Text Available Abstract The renal artery pseudoaneurysm embody a rare vascular complication coming of percutaneous procedures, renal biopsy, nephrectomy, penetrating traumas and more rarely blunt traumas. The clinical can be vary according the patient, the haematuria is the symptom more commom. Is necessary a high level of clinical suspicion for your diagnosis, this can be elucidated by through complementary exams as the eco-color Doppler and the computed tomography scan (CT. This report is a case of a patient submitted a right percutaneous renal biopsy and that, after the procedure started with macroscopic haematuria, urinary tenesmus and hypogastric pain. The diagnosis of pseudoaneurysm was given after one week of evolution when the patient was hospitalized because gross haematuria, tachycardia, hypotension and hypochondrium pain. In the angiotomography revealed a focal dilation of the accessory right renal inferior polar artery, dilation of renal pelvis and all the ureteral course with presence hyperdenso material (clots inside the middle third of the ureter. The treatment for the majority of this cases are conservative, through arterial embolization, indicated for thouse of smaller dimensions in patients who are hemodynamically stable. However, it was decided by clinical treatment with aminocaproic acid 1 g, according to previous studies for therapy of haematuria. The patient received discharge without evidence of macroscopic haematuria and with normal renal ultrasound, following ambulatory care.

  1. Avalanche photoconductive switching

    Science.gov (United States)

    Pocha, M. D.; Druce, R. L.; Wilson, M. J.; Hofer, W. W.

    This paper describes work being done at Lawrence Livermore National Laboratory on the avalanche mode of operation of laser triggered photoconductive switches. We have been able to generate pulses with amplitudes of 2 kV to 35 kV and rise times of 300 to 500 ps, and with a switching gain (energy of output electrical pulse vs energy of trigger optical pulse) of 10(exp 3) to over 10(exp 5). Switches with two very different physical configurations and with two different illumination wavelengths (1.06 micrometer, 890 nm) exhibit very similar behavior. The avalanche switching behavior, therefore, appears to be related to the material parameters rather than the optical wavelength or switch geometry. Considerable further work needs to be done to fully characterize and understand this mode of operation.

  2. Avalanche photoconductive switching

    Energy Technology Data Exchange (ETDEWEB)

    Pocha, M.D.; Druce, R.L.; Wilson, M.J.; Hofer, W.W.

    1989-01-01

    This paper describes work being done at Lawrence Livermore National Laboratory on the avalanche mode of operation of laser triggered photoconductive switches. We have been able to generate pulses with amplitudes of 2 kV--35 kV and rise times of 300--500 ps, and with a switching gain (energy of output electrical pulse vs energy of trigger optical pulse) of 10{sup 3} to over 10{sup 5}. Switches with two very different physical configurations and with two different illumination wavelengths (1.06 {mu}m, 890 nm) exhibit very similar behavior. The avalanche switching behavior, therefore, appears to be related to the material parameters rather than the optical wavelength or switch geometry. Considerable further work needs to be done to fully characterize and understand this mode of operation. 3 refs., 6 figs.

  3. Aberrant overian artery originating from the Ilolumbar artery: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Eun; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2016-05-15

    Here, we report a case of a 30-year-old woman who presented with primary postpartum hemorrhage due to uterine atony. She received uterine artery embolization (UAE). During left internal iliac arteriography, an aberrant left ovarian artery originating from the left iliolumbar artery was visualized. The aberrant left ovarian artery was connected to the left uterine artery via prominent collateral vessels. It supplied a significant amount of blood to the fundus of the uterus. Bilateral hypertrophied uterine arteries were embolized very carefully so that the embolic material did not reflux into the aberrant left ovarian artery. After the procedure, her vaginal bleeding was successfully controlled. Accurate understanding of anatomical variations of the ovarian artery is essential to avoid failure in controlling postpartum hemorrhage with UAE.

  4. Aberrant overian artery originating from the Ilolumbar artery: A case report

    International Nuclear Information System (INIS)

    Lee, Ji Eun; Lee, Jae Myeong

    2016-01-01

    Here, we report a case of a 30-year-old woman who presented with primary postpartum hemorrhage due to uterine atony. She received uterine artery embolization (UAE). During left internal iliac arteriography, an aberrant left ovarian artery originating from the left iliolumbar artery was visualized. The aberrant left ovarian artery was connected to the left uterine artery via prominent collateral vessels. It supplied a significant amount of blood to the fundus of the uterus. Bilateral hypertrophied uterine arteries were embolized very carefully so that the embolic material did not reflux into the aberrant left ovarian artery. After the procedure, her vaginal bleeding was successfully controlled. Accurate understanding of anatomical variations of the ovarian artery is essential to avoid failure in controlling postpartum hemorrhage with UAE

  5. Animal models of cerebral arterial gas embolism

    NARCIS (Netherlands)

    Weenink, Robert P.; Hollmann, Markus W.; van Hulst, Robert A.

    2012-01-01

    Cerebral arterial gas embolism is a dreaded complication of diving and invasive medical procedures. Many different animal models have been used in research on cerebral arterial gas embolism. This review provides an overview of the most important characteristics of these animal models. The properties

  6. Arterial embolism

    Science.gov (United States)

    ... when a clot in a vein enters the right side of the heart and passes through a hole into the left side. The clot can then move to an artery and block blood flow to the brain (stroke) or other organs. If a clot involves ...

  7. Energy losses in switches

    International Nuclear Information System (INIS)

    Martin, T.H.; Seamen, J.F.; Jobe, D.O.

    1993-01-01

    The authors experiments show energy losses between 2 and 10 times that of the resistive time predictions. The experiments used hydrogen, helium, air, nitrogen, SF 6 polyethylene, and water for the switching dielectric. Previously underestimated switch losses have caused over predicting the accelerator outputs. Accurate estimation of these losses is now necessary for new high-efficiency pulsed power devices where the switching losses constitute the major portion of the total energy loss. They found that the switch energy losses scale as (V peak I peak ) 1.1846 . When using this scaling, the energy losses in any of the tested dielectrics are almost the same. This relationship is valid for several orders of magnitude and suggested a theoretical basis for these results. Currents up to .65 MA, with voltages to 3 MV were applied to various gaps during these experiments. The authors data and the developed theory indicates that the switch power loss continues for a much longer time than the resistive time, with peak power loss generally occurring at peak current in a ranging discharge instead of the early current time. All of the experiments were circuit code modeled after developing a new switch loss version based on the theory. The circuit code predicts switch energy loss and peak currents as a function of time. During analysis of the data they noticed slight constant offsets between the theory and data that depended on the dielectric. They modified the plasma conductivity for each tested dielectric to lessen this offset

  8. Resistance switching in silver - manganite contacts

    International Nuclear Information System (INIS)

    Gomez-Marlasca, F; Levy, P

    2009-01-01

    We investigate the electric pulse induced resistance switching in a transition metal oxide-metal contact at room temperature - a non volatile, reversible and multilevel memory device. Using a simple multiterminal configuration, we find that the complementary effect -in which the contact resistance of each pulsed electrode displays variations of opposite sign- is strongly influenced by the history of the pulsing procedure. Loops performed by varying the magnitude and sign of the stimulus at each pulsed electrode allow to disentangle their sole contribution at different stages of the process. Electromigration of oxygen ions and vacancies is discussed as participating at the core of the underlying mechanisms for resistance switching.

  9. Resistance switching in silver - manganite contacts

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Marlasca, F [Materia Condensada GIA GAIANN CAC -CNEA, and Instituto de Nanociencia y Nanotecnologia, CNEA, Gral Paz 1499 (1650) San Martin, Pcia. Buenos Aires (Argentina); Levy, P, E-mail: levy@cnea.gov.a

    2009-05-01

    We investigate the electric pulse induced resistance switching in a transition metal oxide-metal contact at room temperature - a non volatile, reversible and multilevel memory device. Using a simple multiterminal configuration, we find that the complementary effect -in which the contact resistance of each pulsed electrode displays variations of opposite sign- is strongly influenced by the history of the pulsing procedure. Loops performed by varying the magnitude and sign of the stimulus at each pulsed electrode allow to disentangle their sole contribution at different stages of the process. Electromigration of oxygen ions and vacancies is discussed as participating at the core of the underlying mechanisms for resistance switching.

  10. Electromechanical magnetization switching

    Energy Technology Data Exchange (ETDEWEB)

    Chudnovsky, Eugene M. [Department of Physics and Astronomy, Lehman College and Graduate School, The City University of New York, 250 Bedford Park Boulevard West, Bronx, New York 10468-1589 (United States); Jaafar, Reem [Department of Mathematics, Engineering and Computer Science, LaGuardia Community College, The City University of New York, 31-10 Thomson Avenue, Long Island City, New York 11101 (United States)

    2015-03-14

    We show that the magnetization of a torsional oscillator that, in addition to the magnetic moment also possesses an electrical polarization, can be switched by the electric field that ignites mechanical oscillations at the frequency comparable to the frequency of the ferromagnetic resonance. The 180° switching arises from the spin-rotation coupling and is not prohibited by the different symmetry of the magnetic moment and the electric field as in the case of a stationary magnet. Analytical equations describing the system have been derived and investigated numerically. Phase diagrams showing the range of parameters required for the switching have been obtained.

  11. Electromechanical magnetization switching

    International Nuclear Information System (INIS)

    Chudnovsky, Eugene M.; Jaafar, Reem

    2015-01-01

    We show that the magnetization of a torsional oscillator that, in addition to the magnetic moment also possesses an electrical polarization, can be switched by the electric field that ignites mechanical oscillations at the frequency comparable to the frequency of the ferromagnetic resonance. The 180° switching arises from the spin-rotation coupling and is not prohibited by the different symmetry of the magnetic moment and the electric field as in the case of a stationary magnet. Analytical equations describing the system have been derived and investigated numerically. Phase diagrams showing the range of parameters required for the switching have been obtained

  12. JUNOS Enterprise Switching

    CERN Document Server

    Reynolds, Harry

    2009-01-01

    JUNOS Enterprise Switching is the only detailed technical book on Juniper Networks' new Ethernet-switching EX product platform. With this book, you'll learn all about the hardware and ASIC design prowess of the EX platform, as well as the JUNOS Software that powers it. Not only is this extremely practical book a useful, hands-on manual to the EX platform, it also makes an excellent study guide for certification exams in the JNTCP enterprise tracks. The authors have based JUNOS Enterprise Switching on their own Juniper training practices and programs, as well as the configuration, maintenanc

  13. Switch mode power supply

    International Nuclear Information System (INIS)

    Kim, Hui Jun

    1993-06-01

    This book concentrates on switch mode power supply. It has four parts, which are introduction of switch mode power supply with DC-DC converter such as Buck converter boost converter, Buck-boost converter and PWM control circuit, explanation for SMPS with DC-DC converter modeling and power mode control, resonance converter like resonance switch, converter, multi resonance converter and series resonance and parallel resonance converters, basic test of SMPS with PWM control circuit, Buck converter, Boost converter, flyback converter, forward converter and IC for control circuit.

  14. Re-implant of the right coronary artery: a surgical technique for the treatment of ostial lesions

    Directory of Open Access Journals (Sweden)

    Bongiovani Hércules Lisboa

    2002-01-01

    Full Text Available Previously described surgical treatment for ostial coronary artery stenosis relied on either venous or arterial bypasses or ostial patch angioplasty. These surgical procedures are performed with bovine pericardium, saphenous vein or internal thoracic artery. We describe a technique of right coronary artery re-implantation into the aorta. The procedure was performed in four patients with right coronary artery ostial stenosis along with other left coronary artery lesions.

  15. Successful transcatheter closure of coronary artery fistula in a child with single coronary artery: a heavy load and a long road.

    Science.gov (United States)

    Phasalkar, Manjunath; Thakkar, Bhavesh; Poptani, Vishal

    2013-07-01

    Single coronary artery is an uncommon variation of the coronary circulation. After transposition of great arteries, coronary artery fistulas are the most common associated cardiac anomalies in these patients. Transcatheter closure of coronary artery fistula (CAF) involving single coronary artery is a challenging intervention. In the absence of contralateral coronary artery, a complex anatomy of the CAF and a large myocardial perfusion territory of the dominant circulation pose an additional risk during interventional procedure. We report our experience of a successful transcatheter closure of a coronary artery fistula in a patient with single coronary artery. Copyright © 2013 Wiley Periodicals, Inc.

  16. Optical switching systems using nanostructures

    DEFF Research Database (Denmark)

    Stubkjær, Kristian

    2004-01-01

    High capacity multiservice optical networks require compact and efficient switches. The potential benefits of optical switch elements based on nanostructured material are reviewed considering various material systems.......High capacity multiservice optical networks require compact and efficient switches. The potential benefits of optical switch elements based on nanostructured material are reviewed considering various material systems....

  17. Central retinal and posterior ciliary artery occlusion after particle embolization of the external carotid artery system.

    Science.gov (United States)

    Mames, R N; Snady-McCoy, L; Guy, J

    1991-04-01

    A 15-year-old boy underwent neuroradiologic embolization of the left internal maxillary artery with polyvinyl alcohol to stop traumatic epistaxis after failure of surgical clipping and nasal packing. Selective catheterization of the external carotid artery before embolization showed a faint choroidal blush. Although the procedure provided hemostasis, embolization to the central retinal artery and ciliary arteries resulted in loss of vision. The route of the emboli to the eye was via the anastomotic network of the lacrimal artery supplied by the external carotid artery system. Neuroradiologic embolization of the external carotid artery is an effective mode of therapy for dural-cavernous fistulas when fed by the external carotid artery system. Because the blood flow to the brain and eye is predominantly supplied by the internal carotid artery, embolization of the external carotid artery is considered relatively safe. The authors document the importance of recognition of the choroidal blush during selective external carotid artery angiography as a sign of collateral blood flow to the eye. Physicians and patients need to be aware of the risk of blindness as a complication of external carotid artery embolization when this sign is present.

  18. Angioplasty in stenosis of the innominate artery

    International Nuclear Information System (INIS)

    Kobinia, G.S.; Bergmann, H. Jr.

    1983-01-01

    We describe a successful percutaneous transluminal dilatation (PTD) of an innominate artery stenosis in a 40-year-old patient with aortic arch syndrome. Five years earlier both a left central carotid artery occlusion and an innominate and left subclavian artery stenosis were treated by grafting from the aorta to the distal vessels. At recurrence of the neurological symptoms, reocclusion of the graft to the innominate artery and subtotal stenosis of the left carotid anastomosis were noted. The prevent the hazards of a reoperation, the innominate artery stenosis was dilated by means of PTD via the right brachial artery. Success of the procedure was demonstrated by Doppler sonography and angiography. It appears that PTD serves as an excellent method of treating stenoses of the aortic arch branches in aortic arch syndrome. (orig.)

  19. Innominate artery war injury

    Directory of Open Access Journals (Sweden)

    Ilić Radoje

    2005-01-01

    Full Text Available Aim. A case is reported of successfully surgically treated explosive war injury to the innominate artery. Case report. A 26 - year-old soldier was injured in combat by a fragment of mortar shell. In the field hospital, the wound gauze packing was applied, followed by orotracheal intubation and thoracic drainage. The soldier was admitted to MMA six hours later. Physical examination, on admission, revealed huge swelling of the neck, the absence of pulse in the right arm and the right common carotid artery. Chest x-ray revealed hemopneumothorax of the right side and the foreign metal body in the projection of the right sternoclavicular joint. Due to the suspicion of large vessel injury, a median sternotomy was immediately performed. Surgery revealed disrupted bifurcation of the right innominate artery, so the ligation was performed. Aortography was performed postoperatively, followed by the reconstruction of innominate bifurcation with synthetic grafts. Control aortography showed good graft patency, and the patient was discharged from the hospital in good general condition with palpable pulses and mild anisocoria as a sole neurological sequela. Conclusion. A rare and life-threatening injury was successfully managed, mainly due to the rational treatment carried out in the field hospital that helped the injured to survive and arrive to the institution capable of performing the most sophisticated diagnostic and therapeutic procedures.

  20. Duplication of Inferior Gluteal Artery and Course of Superior Gluteal Artery Through the Lumbosacral Trunk

    Directory of Open Access Journals (Sweden)

    Satheesha Nayak B

    2017-07-01

    Full Text Available Internal iliac artery (IIA shows great deal of variations in its branching pattern. The knowledge of its variant branches is required for successful surgical, orthopedic, plastic surgery and radiological procedures. We observed variations of some of the branches of right IIA in an adult male cadaver. The iliolumbar artery originated from the main trunk of the IIA. After this, IIA divided into anterior and posterior divisions. The posterior division gave lateral sacral and superior gluteal arteries. Superior gluteal artery pierced the lumbosacral trunk before leaving the pelvis. The anterior division further divided into anterior and posterior trunks. Anterior trunk gave rise to superior vesical, inferior vesical, middle rectal and obturator arteries. The posterior trunk gave two inferior gluteal arteries and an internal pudendal artery.

  1. Emergency procedures

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following subjects are discussed - Emergency Procedures: emergency equipment, emergency procedures; emergency procedure involving X-Ray equipment; emergency procedure involving radioactive sources

  2. Double profunda brachii artery

    Directory of Open Access Journals (Sweden)

    Gavishiddappa A Hadimani

    2016-01-01

    Full Text Available Brachial artery (BA is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii artery 2 arises distal to the profunda brachii artery 1. Both the arteries run inferolaterally in the spiral groove along with radial nerve. Variations of profunda brachii artery are important during harvesting of the lateral arm flaps and may lead to inadvertent injury during percutaneous arterial catheterization or injection of drugs.

  3. Acute arterial occlusion - kidney

    Science.gov (United States)

    ... main artery to the kidney is called the renal artery. Reduced blood flow through the renal artery can hurt kidney function. ... need include: Duplex Doppler ultrasound exam of the renal arteries to test blood flow MRI of the kidney arteries, which can show ...

  4. FAS: Using FPGA to Accelerate and Secure SDN Software Switches

    Directory of Open Access Journals (Sweden)

    Wenwen Fu

    2018-01-01

    Full Text Available Software-Defined Networking (SDN promises the vision of more flexible and manageable networks but requires certain level of programmability in the data plane to accommodate different forwarding abstractions. SDN software switches running on commodity multicore platforms are programmable and are with low deployment cost. However, the performance of SDN software switches is not satisfactory due to the complex forwarding operations on packets. Moreover, this may hinder the performance of real-time security on software switch. In this paper, we analyze the forwarding procedure and identify the performance bottleneck of SDN software switches. An FPGA-based mechanism for accelerating and securing SDN switches, named FAS (FPGA-Accelerated SDN software switch, is proposed to take advantage of the reconfigurability and high-performance advantages of FPGA. FAS improves the performance as well as the capacity against malicious traffic attacks of SDN software switches by offloading some functional modules. We validate FAS on an FPGA-based network processing platform. Experiment results demonstrate that the forwarding rate of FAS can be 44% higher than the original SDN software switch. In addition, FAS provides new opportunity to enhance the security of SDN software switches by allowing the deployment of bump-in-the-wire security modules (such as packet detectors and filters in FPGA.

  5. Coronary Artery Bypass in Octogenarians

    Directory of Open Access Journals (Sweden)

    Chen-Yen Chien

    2012-09-01

    Full Text Available Prevalence of coronary artery disease (CAD has increased with the expansion of life span among the elderly population in the world. Hence, the issue of the coronary artery bypass in octogenarians has attracted more attention. Recent literature about the topic revealed nearly the same excellent results as those in the younger population under the newly developed operative techniques and improving concept in perioperative management and postoperative care. In this article, we review the current status of the procedure that was thought to be dangerous in the earlier era, including its risk factors, result, and benefit.

  6. [Atherectomy for peripheral arterial disease].

    Science.gov (United States)

    Londero, Louise Skovgaard; Høgh, Annette Langager; Lindholt, Jes Sanddal

    2015-04-13

    Symptomatic peripheral arterial disease is managed according to national and international guidelines and the number of vascular reconstructions performed each year has increased over the past decade mainly due to an increasing frequency of endovascular procedures. Atherectomy as an alternative to the established treatment of symptomatic peripheral arterial disease has recently been analysed in a Cochrane review. In Denmark, atherectomy is not performed and so far the evidence is poor as the method is not an alternative to the established treatment in this country.

  7. Percutaneous transluminal angioplasty of the superficial femoral artery by retrograde catheterization via the popliteal artery

    DEFF Research Database (Denmark)

    Tønnesen, K H; Sager, P; Karle, A

    1988-01-01

    We report the results of 50 angioplasty procedures via the popliteal artery. A 3-year follow-up including control of blood pressures at ankle and toe levels show results comparable to reports in the literature. This new approach for angioplasty of the superficial femoral artery and eventually of ...

  8. Energy reversible switching from amorphous metal based nanoelectromechanical switch

    KAUST Repository

    Mayet, Abdulilah M.; Smith, Casey; Hussain, Muhammad Mustafa

    2013-01-01

    We report observation of energy reversible switching from amorphous metal based nanoelectromechanical (NEM) switch. For ultra-low power electronics, NEM switches can be used as a complementary switching element in many nanoelectronic system applications. Its inherent zero power consumption because of mechanical detachment is an attractive feature. However, its operating voltage needs to be in the realm of 1 volt or lower. Appropriate design and lower Young's modulus can contribute achieving lower operating voltage. Therefore, we have developed amorphous metal with low Young's modulus and in this paper reporting the energy reversible switching from a laterally actuated double electrode NEM switch. © 2013 IEEE.

  9. Energy reversible switching from amorphous metal based nanoelectromechanical switch

    KAUST Repository

    Mayet, Abdulilah M.

    2013-08-01

    We report observation of energy reversible switching from amorphous metal based nanoelectromechanical (NEM) switch. For ultra-low power electronics, NEM switches can be used as a complementary switching element in many nanoelectronic system applications. Its inherent zero power consumption because of mechanical detachment is an attractive feature. However, its operating voltage needs to be in the realm of 1 volt or lower. Appropriate design and lower Young\\'s modulus can contribute achieving lower operating voltage. Therefore, we have developed amorphous metal with low Young\\'s modulus and in this paper reporting the energy reversible switching from a laterally actuated double electrode NEM switch. © 2013 IEEE.

  10. Interventional treatment of arterial complications in post renal transplantation

    International Nuclear Information System (INIS)

    Qian Xiaojun; Dai Dingke; Zhai Renyou

    2004-01-01

    Objective: To report our experience of interventional procedure for arterial complications in post renal transplantation and to evaluate its clinical value. Methods: In a retrospective analysis of renal transplantations in our center, 52 cases of renal allograft artery abnormalities had taken angiography. Interventional procedure included transluminal angioplasty of arterial stenoses, treatment of arterial occlusion, and embolization of pseudoaneurysm. Results: Renal allograft artery abnormalities included artery stenosis (n=21), artery thrombosis (n=13) and embolision (n=1), renal artery pseudoaneurysms (n=2), and decrease of renal artery flow (n=3). Of the 21 artery stenosis, 2 grafts with artery stenosis were lost because the stenosis could not be corrected, and 3 with mild stenosis received no treatment. Another 16 accepted renal artery angioplasty (balloon dilation, n=12, and stent implantation, n=4). 14 achieved long-term allograft function. 1 graft was lost because renal function failed to recover. Restenosis occurred in one stent implantation, and lost the allograft function after secondary dilation. 13 cases received thrombolytic therapy through artery catheter for thrombosis and 9 achieved long-term allograft function. Thrombolyses failed in 3 cases, and renal function failed to recover in 1 case. One pseudoaneurysm received stent implantation after embolization, and got a short-term allograft function. The other one received allograft excision. Conclusion: Intravascular interventional therapy will be the first-line therapy for any indications of complication in post renal transplantation, and it can surely save the kidney in a majority of instances. (authors)

  11. Optical computer switching network

    Science.gov (United States)

    Clymer, B.; Collins, S. A., Jr.

    1985-01-01

    The design for an optical switching system for minicomputers that uses an optical spatial light modulator such as a Hughes liquid crystal light valve is presented. The switching system is designed to connect 80 minicomputers coupled to the switching system by optical fibers. The system has two major parts: the connection system that connects the data lines by which the computers communicate via a two-dimensional optical matrix array and the control system that controls which computers are connected. The basic system, the matrix-based connecting system, and some of the optical components to be used are described. Finally, the details of the control system are given and illustrated with a discussion of timing.

  12. Hepatic falciform artery

    International Nuclear Information System (INIS)

    Jaques, Paul F.; Mauro, Matthew A.; Sandhu, Jeet

    1997-01-01

    The hepatic falciform artery is an occasional terminal branch of the left or middle hepatic artery, and may provide an uncommon but important collateral route when the principal visceral arteries are occluded

  13. Correlation of femoral artery vs radial artery pressures with central pressure after cardiopulmonary bypass in children

    International Nuclear Information System (INIS)

    Yaseen, R.; Memon, H.

    2008-01-01

    To assess the effectiveness of femoral and radial arterial lines on the correlation of peripheral and central mean arterial blood pressure in children after discontinuation of cardiopulmonary bypass. Fifty children scheduled for cardiac surgery with cardiopulmonary bypass were included in the study. After approval from the hospital ethics committee and informed consent. 50 children undergoing cardiac surgical procedures with cardiopulmonary bypass were randomly assigned to two different groups. In Group- A (RAP, n-2) a radial arterial line and in Group-B (FAP, n-25) a femoral arterial line was used to monitor the blood pressure. Simultaneous mean peripheral arterial pressure and mean central aortic pressure were recorded before cardiopulmonary bypass and 5 mins after separation from the cardiopulmonary bypass. The correlation of mean peripheral arterial pressure (radial and femoral) versus mean aortic pressure were compared. The data was recorded as Mean +- SD and P-value. The ages of children ranged from 4-12 years and their weight from 14.1-28.5 kg. In all of them following cardiopulmonary bypass, aortic pressure correlates better with femoral arterial pressure (p<0.001). The radial arterial line readings under estimated central aortic pressure when compared to femoral arterial line readings. Aortic pressure readings correlate better with femoral arterial pressure than radial arterial pressure in children. (author)

  14. BCP selector valves and limit switches

    International Nuclear Information System (INIS)

    Rippy, G.L.

    1995-01-01

    This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the Electrical/Instrumentation systems for the BCP stream function as required by project criteria. Specifically, the test will verify the operation of the solenoid valves and associated limit switches installed for the BCP portion of W-OO7H. This equipment is part of the B-Plant Process Condensate Treatment Facility

  15. Stochastic Switching Dynamics

    DEFF Research Database (Denmark)

    Simonsen, Maria

    This thesis treats stochastic systems with switching dynamics. Models with these characteristics are studied from several perspectives. Initially in a simple framework given in the form of stochastic differential equations and, later, in an extended form which fits into the framework of sliding...... mode control. It is investigated how to understand and interpret solutions to models of switched systems, which are exposed to discontinuous dynamics and uncertainties (primarily) in the form of white noise. The goal is to gain knowledge about the performance of the system by interpreting the solution...

  16. Double profunda brachii artery

    OpenAIRE

    Gavishiddappa A Hadimani; Jyoti V Hadimani; Ishwar B Bagoji; Shardha Bai Rathod; Balappa M Bannur

    2016-01-01

    Brachial artery (BA) is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii...

  17. Very high plasma switches. Basic plasma physics and switch technology

    International Nuclear Information System (INIS)

    Doucet, H.J.; Roche, M.; Buzzi, J.M.

    1988-01-01

    A review of some high power switches recently developed for very high power technology is made with a special attention to the aspects of plasma physics involved in the mechanisms, which determine the limits of the possible switching parameters

  18. Ultrafast gas switching experiments

    International Nuclear Information System (INIS)

    Frost, C.A.; Martin, T.H.; Patterson, P.E.; Rinehart, L.F.; Rohwein, G.J.; Roose, L.D.; Aurand, J.F.; Buttram, M.T.

    1993-01-01

    We describe recent experiments which studied the physics of ultrafast gas breakdown under the extreme overvoltages which occur when a high pressure gas switch is pulse charged to hundreds of kV in 1 ns or less. The highly overvolted peaking gaps produce powerful electromagnetic pulses with risetimes Khz at > 100 kV/m E field

  19. An integrated circuit switch

    Science.gov (United States)

    Bonin, E. L.

    1969-01-01

    Multi-chip integrated circuit switch consists of a GaAs photon-emitting diode in close proximity with S1 phototransistor. A high current gain is obtained when the transistor has a high forward common-emitter current gain.

  20. The Octopus switch

    NARCIS (Netherlands)

    Havinga, Paul J.M.

    2000-01-01

    This chapter1 discusses the interconnection architecture of the Mobile Digital Companion. The approach to build a low-power handheld multimedia computer presented here is to have autonomous, reconfigurable modules such as network, video and audio devices, interconnected by a switch rather than by a

  1. Untriggered water switching

    International Nuclear Information System (INIS)

    Van Devender, J.P.; Martin, T.H.

    Recent experiments indicate that synchronous untriggered multichannel switching in water will permit the development of relatively simple, ultra-low impedance, short pulse, relativistic electron beam (REB) accelerators. These experiments resulted in the delivery of a 1.5 MV, 0.75 MA, 15 ns pulse into a two-ohm line with a current risetime of 2 x 10 14 A/sec. The apparatus consisted of a 3 MV Marx generator and a series of three 112 cm wide strip water lines separated by two edge-plane water-gap switches. The Marx generator charged the first line in less than 400 ns. The first switch then formed five or more channels. The second line was charged in 60 ns and broke down with 10 to 25 channels at a mean field of 1.6 MV/cm. The closure time of each spark channel along both switches was measured with a streak camera and showed low jitter. The resulting fast pulse line construction is simpler and should provide considerable costs savings from previous designs. Multiples of these low impedance lines in parallel can be employed to obtain power levels in the 10 14 W range for REB fusion studies. (U.S.)

  2. Transpedal approach for iliac artery stenting: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Zachariah, Jips J., E-mail: jzachariah@chpnet.org [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Ratcliffe, Justin A.; Ruisi, Michael; Puma, Joseph [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Bertrand, Olivier [Quebec Heart and Lung Institute, Quebec (Canada); Kwan, Tak [Mount Sinai Beth Israel Hospital, New York, NY (Israel)

    2016-12-15

    Objective: To demonstrate the safety and feasibility of the transpedal approach as an alternate arterial access site for iliac artery intervention. Background: The common femoral artery is the traditional access site for the endovascular treatment of iliac artery stenoses. However, this approach is associated with complication rates as high as 2%, including retroperitoneal bleeding which carries high patient morbidity and mortality. Furthermore, the standard femoral approach is associated with longer recovery times and longer time to ambulation which are important considerations especially when performing procedures in an ambulatory setting. Methods: Twelve patients were prospectively followed after treatment for symptomatic iliac artery stenosis via transpedal access. Under ultrasound guidance, one of the pedal arteries was visualized and accessed, and stenting of the iliac arteries were performed as per protocol. The patient was monitored immediately post procedure and clinical follow up was performed at one week and one month later. Results: The average age of the patients was 71 years old. 58% were male. Most patients had Rutherford class III symptoms. Successful stent placement was achieved in all 12 patients via transpedal access. No conversion to femoral access was required. No complications immediately post procedure nor at any time period during follow up were noted. Lower extremity arterial duplex at one month showed patent stents and patent pedal access site vessels in all patients. Conclusion: Transpedal arterial access may be a safe and feasible approach for iliac artery stenting. Given the possible benefits of avoiding femoral artery access, larger studies should be conducted directly comparing the different approaches.

  3. Long-term results after atrial correction of complete transposition of the great arteries.

    Science.gov (United States)

    Merlo, M; de Tommasi, S M; Brunelli, F; Abbruzzese, P A; Crupi, G; Ghidoni, I; Casari, A; Pitì, A; Mamprin, F; Parenzan, L

    1991-02-01

    This study presents the late results for the first 104 consecutive patients surviving and atrial repair for transposition of the great arteries (TGA) between January 1971 and December 1978 (group 1). Mean follow-up was 12 years (range, 0.1 to 17.7 years). The actuarial survival rate at 18 years was 84.2% (70% confidence limits, 79% to 88%) for simple TGA and 93.7% (70% confidence limits, 84% to 97%) for complex TGA. Nine of the 11 deaths were sudden. Two (2.6%) of the 78 late survivors operated on for simple TGA are in New York Heart Association functional class III or IV versus 4 (26.7%) of the 15 survivors with complex TGA; the other patients are doing very well. To better assess long-term results, we report the findings for randomly obtained electrocardiograms, Holter monitor recordings, radionuclide angiographic studies, and cardiac catheterizations performed in 1987 in a larger group of 159 long-term survivors of atrial repair operated on at Ospedale Riuniti di Bergamo from January 1971 to December 1984 (group 2), which includes all of group 1. The findings confirm that the arterial switch repair is the procedure of choice for complex TGA and that there is a major incidence (approximately 10%) of systemic right ventricular dysfunction and rhythm disturbances after the atrial repair. On the other hand, our late survival rate at 18 years of 84% for simple TGA with 97.5% of the patients in functional class I is a result that should be kept in mind, especially in institutions where the arterial switch is a relatively new approach and presumably is a higher risk to cause early death.

  4. Primary extracranial vertebral artery aneurysms.

    Science.gov (United States)

    Morasch, Mark D; Phade, Sachin V; Naughton, Peter; Garcia-Toca, Manuel; Escobar, Guillermo; Berguer, Ramon

    2013-05-01

    Extracranial vertebral artery aneurysms are uncommon and are usually associated with trauma or dissection. Primary cervical vertebral aneurysms are even rarer and are not well described. The presentation and natural history are unknown and operative management can be difficult. Accessing aneurysms at the skull base can be difficult and, because the frail arteries are often afflicted with connective tissue abnormalities, direct repair can be particularly challenging. We describe the presentation and surgical management of patients with primary extracranial vertebral artery aneurysms. In this study we performed a retrospective, multi-institutional review of patients with primary aneurysms within the extracranial vertebral artery. Between January 2000 and January 2011, 7 patients, aged 12-56 years, were noted to have 9 primary extracranial vertebral artery aneurysms. All had underlying connective tissue or another hereditary disorder, including Ehler-Danlos syndrome (n=3), Marfan's disease (n=2), neurofibromatosis (n=1), and an unspecified connective tissue abnormality (n=1). Eight of 9 aneurysms were managed operatively, including an attempted bypass that ultimately required vertebral ligation; the contralateral aneurysm on this patient has not been treated. Open interventions included vertebral bypass with vein, external carotid autograft, and vertebral transposition to the internal carotid artery. Special techniques were used for handling the anastomoses in patients with Ehler-Danlos syndrome. Although endovascular exclusion was not performed in isolation, 2 hybrid procedures were performed. There were no instances of perioperative stroke or death. Primary extracranial vertebral artery aneurysms are rare and occur in patients with hereditary disorders. Operative intervention is warranted in symptomatic patients. Exclusion and reconstruction may be performed with open and hybrid techniques with low morbidity and mortality. Copyright © 2013 Elsevier Inc. All rights

  5. Branches of the Facial Artery.

    Science.gov (United States)

    Hwang, Kun; Lee, Geun In; Park, Hye Jin

    2015-06-01

    The aim of this study is to review the name of the branches, to review the classification of the branching pattern, and to clarify a presence percentage of each branch of the facial artery, systematically. In a PubMed search, the search terms "facial," AND "artery," AND "classification OR variant OR pattern" were used. The IBM SPSS Statistics 20 system was used for statistical analysis. Among the 500 titles, 18 articles were selected and reviewed systematically. Most of the articles focused on "classification" according to the "terminal branch." Several authors classified the facial artery according to their terminal branches. Most of them, however, did not describe the definition of "terminal branch." There were confusions within the classifications. When the inferior labial artery was absent, 3 different types were used. The "alar branch" or "nasal branch" was used instead of the "lateral nasal branch." The angular branch was used to refer to several different branches. The presence as a percentage of each branch according to the branches in Gray's Anatomy (premasseteric, inferior labial, superior labial, lateral nasal, and angular) varied. No branch was used with 100% consistency. The superior labial branch was most frequently cited (95.7%, 382 arteries in 399 hemifaces). The angular branch (53.9%, 219 arteries in 406 hemifaces) and the premasseteric branch were least frequently cited (53.8%, 43 arteries in 80 hemifaces). There were significant differences among each of the 5 branches (P < 0.05) except between the angular branch and the premasseteric branch and between the superior labial branch and the inferior labial branch. The authors believe identifying the presence percentage of each branch will be helpful for surgical procedures.

  6. Control synthesis of switched systems

    CERN Document Server

    Zhao, Xudong; Niu, Ben; Wu, Tingting

    2017-01-01

    This book offers its readers a detailed overview of the synthesis of switched systems, with a focus on switching stabilization and intelligent control. The problems investigated are not only previously unsolved theoretically but also of practical importance in many applications: voltage conversion, naval piloting and navigation and robotics, for example. The book considers general switched-system models and provides more efficient design methods to bring together theory and application more closely than was possible using classical methods. It also discusses several different classes of switched systems. For general switched linear systems and switched nonlinear systems comprising unstable subsystems, it introduces novel ideas such as invariant subspace theory and the time-scheduled Lyapunov function method of designing switching signals to stabilize the underlying systems. For some typical switched nonlinear systems affected by various complex dynamics, the book proposes novel design approaches based on inte...

  7. Synchronization Between Two Different Switched Chaotic Systems By Switching Control

    Directory of Open Access Journals (Sweden)

    Du Li Ming

    2016-01-01

    Full Text Available This paper is concerned with the synchronization problem of two different switched chaotic systems, considering the general case that the master-slave switched chaotic systems have uncertainties. Two basic problems are considered: one is projective synchronization of switched chaotic systems under arbitrary switching; the other is projective synchronization of switched chaotic systems by design of switching when synchronization cannot achieved by using any subsystems alone. For the two problems, common Lyapunov function method and multiple Lyapunov function method are used respectively, an adaptive control scheme has been presented, some sufficient synchronization conditions are attainted, and the switching signal is designed. Finally, the numerical simulation is provide to show the effectiveness of our method.

  8. Rhabdomyosarcoma of the pulmonary artery

    International Nuclear Information System (INIS)

    Barth, J.; Lehmann, H.; Thermann, M.; Horny, H.P.; Stein, H.; Kiel Univ.; Kiel Univ.; Kiel Univ.

    1982-01-01

    A case of a 55-year-old man with the histological diagnosis rhabdomyosarcoma of the left pulmonary artery has been seen. Lung scanning and pulmonary arteriography are the clues for the diagnostical procedure. 55 cases from the literature are reviewed and clinical findings of the early and late stages of the diseases are discussed. Surgical treatment is the therapy of choice if ever possible; aggressive chemotherapy might be an acceptable alternative. (orig.) [de

  9. Laser activated superconducting switch

    International Nuclear Information System (INIS)

    Wolf, A.A.

    1976-01-01

    A superconducting switch or bistable device is described consisting of a superconductor in a cryogen maintaining a temperature just below the transition temperature, having a window of the proper optical frequency band for passing a laser beam which may impinge on the superconductor when desired. The frequency of the laser is equal to or greater than the optical absorption frequency of the superconducting material and is consistent with the ratio of the gap energy of the switch material to Planck's constant, to cause depairing of electrons, and thereby normalize the superconductor. Some embodiments comprise first and second superconducting metals. Other embodiments feature the two superconducting metals separated by a thin film insulator through which the superconducting electrons tunnel during superconductivity

  10. Optical fiber switch

    Science.gov (United States)

    Early, James W.; Lester, Charles S.

    2002-01-01

    Optical fiber switches operated by electrical activation of at least one laser light modulator through which laser light is directed into at least one polarizer are used for the sequential transport of laser light from a single laser into a plurality of optical fibers. In one embodiment of the invention, laser light from a single excitation laser is sequentially transported to a plurality of optical fibers which in turn transport the laser light to separate individual remotely located laser fuel ignitors. The invention can be operated electro-optically with no need for any mechanical or moving parts, or, alternatively, can be operated electro-mechanically. The invention can be used to switch either pulsed or continuous wave laser light.

  11. Coulomb Blockade Plasmonic Switch.

    Science.gov (United States)

    Xiang, Dao; Wu, Jian; Gordon, Reuven

    2017-04-12

    Tunnel resistance can be modulated with bias via the Coulomb blockade effect, which gives a highly nonlinear response current. Here we investigate the optical response of a metal-insulator-nanoparticle-insulator-metal structure and show switching of a plasmonic gap from insulator to conductor via Coulomb blockade. By introducing a sufficiently large charging energy in the tunnelling gap, the Coulomb blockade allows for a conductor (tunneling) to insulator (capacitor) transition. The tunnelling electrons can be delocalized over the nanocapacitor again when a high energy penalty is added with bias. We demonstrate that this has a huge impact on the plasmonic resonance of a 0.51 nm tunneling gap with ∼70% change in normalized optical loss. Because this structure has a tiny capacitance, there is potential to harness the effect for high-speed switching.

  12. Cryogenic switched MOSFET characterization

    Science.gov (United States)

    1981-01-01

    Both p channel and n channel enhancement mode MOSFETs can be readily switched on and off at temperatures as low as 2.8 K so that switch sampled readout of a VLWIR Ge:Ga focal plane is electronically possible. Noise levels as low as 100 rms electrons per sample (independent of sample rate) can be achieved using existing p channel MOSFETs, at overall rates up to 30,000 samples/second per multiplexed channel (e.g., 32 detectors at a rate of almost 1,000 frames/second). Run of the mill devices, including very low power dissipation n channel FETs would still permit noise levels of the order of 500 electrons/sample.

  13. Practical switching power supply design

    CERN Document Server

    Brown, Martin C

    1990-01-01

    Take the ""black magic"" out of switching power supplies with Practical Switching Power Supply Design! This is a comprehensive ""hands-on"" guide to the theory behind, and design of, PWM and resonant switching supplies. You'll find information on switching supply operation and selecting an appropriate topology for your application. There's extensive coverage of buck, boost, flyback, push-pull, half bridge, and full bridge regulator circuits. Special attention is given to semiconductors used in switching supplies. RFI/EMI reduction, grounding, testing, and safety standards are also deta

  14. Classification of Distal Fingertip Amputation Based on the Arterial System for Replantation

    OpenAIRE

    Park, Hyun Chul; Bahar-Moni, Ahmed Suparno; Cho, Sang Hyun; Kim, Sang Soo; Park, Hyun Sik; Ahn, Sang Cheon

    2012-01-01

    During replantation of distal fingertip amputation, identification of the artery is the most important but time consuming procedure. Depending on the damaged arterial structure, we classified distal fingertip amputations into 4 zones, on the basis of three dimensional concept. Zone 1 injury was defined as damage to the proximal central pulp artery; zone 2 injury, damage to the branch of the central pulp artery; zone 3 injury, damage to the distal central pulp artery; and zone 4 injury, no inj...

  15. Aborted sudden cardiac death in a young male with anomalous left coronary artery arising from the pulmonary artery

    Directory of Open Access Journals (Sweden)

    Chih-Han Huang

    2017-01-01

    Full Text Available Anomalous left coronary artery arising from the pulmonary artery (ALCAPA is a rare type of congenital coronary abnormality that may be associated with early infant mortality and sudden adult cardiac death. We report a case regarding a 23-year-old male who collapsed during a marathon race and was resuscitated with cardiopulmonary resuscitation. Subsequent workups verified the diagnosis of ALCAPA. The patient underwent surgical intervention with obliteration of the ALCAPA orifice and coronary artery bypass grafting with left internal mammary artery to left anterior descending coronary artery. The procedure was done smoothly, and he was discharged uneventfully.

  16. Measurement of Blood Flow in an Intracranial Artery Bypass From the Internal Maxillary Artery by Intraoperative Duplex Sonography.

    Science.gov (United States)

    Yu, Zaitao; Shi, Xiang'en; Brohi, Shams Raza; Qian, Hai; Liu, Fangjun; Yang, Yang

    2017-02-01

    This study explored the hemodynamic characteristics of a subcranial-intracranial bypass from the internal maxillary artery by measuring blood flow on intraoperative duplex sonography. The hemodynamic parameters of the internal maxillary artery (n = 20), radial artery (n = 20), internal maxillary artery-middle cerebral artery bypass (n = 42), and internal maxillary artery-posterior cerebral artery bypass (n = 9) were measured by intraoperative duplex sonography. There was no significant difference in the internal diameters of the internal maxillary and radial arteries (mean ± SD, 2.51 ± 0.34 versus 2.56 ± 0.22 mm; P = .648). The mean radial artery graft length for subcranial-intracranial bypasses was 88.5 ± 12.78 mm (95% confidence interval [CI], 80.8-90.2 mm). Internal maxillary artery-middle cerebral artery bypasses required a shorter radial artery graft than internal maxillary artery-posterior cerebral artery bypasses (77.8 ± 2.47 versus 104.8 ± 4.77 mm; P = .001). The mean flow volumes were 85.3 ± 18.5 mL/min (95% CI, 76.6-93.9 mL/min) for the internal maxillary artery, 72.6 ± 26.4 mL/min (95% CI, 64.3-80.9 mL/min) for internal maxillary artery-middle cerebral artery bypasses, and 45.4 ± 6.7 mL/min (95% CI, 40.7-50.0 mL/min) for internal maxillary artery-posterior cerebral artery bypasses. All grafts were opened after the success of the salvage procedures had been established, and the early patency rates (1 month after the operation) were 95% for internal maxillary artery-middle cerebral artery bypasses and 100% the internal maxillary artery-posterior cerebral artery bypasses. Measurement of blood flow by intraoperative sonography can be helpful in decision making and predicting graft patency and success after neurosurgical bypass procedures. © 2016 by the American Institute of Ultrasound in Medicine.

  17. Composite Material Switches

    Science.gov (United States)

    Javadi, Hamid (Inventor)

    2002-01-01

    A device to protect electronic circuitry from high voltage transients is constructed from a relatively thin piece of conductive composite sandwiched between two conductors so that conduction is through the thickness of the composite piece. The device is based on the discovery that conduction through conductive composite materials in this configuration switches to a high resistance mode when exposed to voltages above a threshold voltage.

  18. MCT/MOSFET Switch

    Science.gov (United States)

    Rippel, Wally E.

    1990-01-01

    Metal-oxide/semiconductor-controlled thyristor (MCT) and metal-oxide/semiconductor field-effect transistor (MOSFET) connected in switching circuit to obtain better performance. Offers high utilization of silicon, low forward voltage drop during "on" period of operating cycle, fast turnon and turnoff, and large turnoff safe operating area. Includes ability to operate at high temperatures, high static blocking voltage, and ease of drive.

  19. Python Switch Statement

    Directory of Open Access Journals (Sweden)

    2008-06-01

    Full Text Available The Python programming language does not have a built in switch/case control structure as found in many other high level programming languages. It is thought by some that this is a deficiency in the language, and the control structure should be added. This paper demonstrates that not only is the control structure not needed, but that the methods available in Python are more expressive than built in case statements in other high level languages.

  20. Peripheral artery atherectomy

    International Nuclear Information System (INIS)

    Quesnel, C.; Maquin, P.; Railhac, N.; Lefevre, G.; Bossavy, J.B.; Railhac, J.J.

    1988-01-01

    Twenty-one femoropopliteal percutaneous transluminal atherectomies were performed with the Simpson catheter. Evaluation included clinical examination, Doppler ultrasonography (ankle-arm index, before and immediately and 1,3 and 6 months after atherectomy), and angiography (6 months after or for clinical worsening). Twenty of 21 procedures achieved satisfactory vessel patency, with the addition of complementary angioplasty for residual stenosis over 30% (one of three cases). Early thrombosis occurred in only one of 21 cases (absence of platelet inhibitor pretherapy), and no distal embolization occurred. Six-month follow-up showed stable improvements in 11 of 12 patients and restenosis in only one (absence of platelet inhibitor pretherapy). Preliminary results indicate that atherectomy is the method of choice for restoring large lumens, with minimal arterial wall injury and fewer cases of restenosis than with angioplasty

  1. Ferroelectric switching of elastin

    Science.gov (United States)

    Liu, Yuanming; Cai, Hong-Ling; Zelisko, Matthew; Wang, Yunjie; Sun, Jinglan; Yan, Fei; Ma, Feiyue; Wang, Peiqi; Chen, Qian Nataly; Zheng, Hairong; Meng, Xiangjian; Sharma, Pradeep; Zhang, Yanhang; Li, Jiangyu

    2014-01-01

    Ferroelectricity has long been speculated to have important biological functions, although its very existence in biology has never been firmly established. Here, we present compelling evidence that elastin, the key ECM protein found in connective tissues, is ferroelectric, and we elucidate the molecular mechanism of its switching. Nanoscale piezoresponse force microscopy and macroscopic pyroelectric measurements both show that elastin retains ferroelectricity at 473 K, with polarization on the order of 1 μC/cm2, whereas coarse-grained molecular dynamics simulations predict similar polarization with a Curie temperature of 580 K, which is higher than most synthetic molecular ferroelectrics. The polarization of elastin is found to be intrinsic in tropoelastin at the monomer level, analogous to the unit cell level polarization in classical perovskite ferroelectrics, and it switches via thermally activated cooperative rotation of dipoles. Our study sheds light onto a long-standing question on ferroelectric switching in biology and establishes ferroelectricity as an important biophysical property of proteins. This is a critical first step toward resolving its physiological significance and pathological implications. PMID:24958890

  2. A coincidental variation of the axillary artery: the brachioradial artery and the aberrant posterior humeral circumflex artery passing under the tendon of the latissimus dorsi muscle

    Directory of Open Access Journals (Sweden)

    Marek Konarik

    2014-09-01

    Full Text Available A case of anomalous terminal branching of the axillary artery was encountered and described in a left upper limb of a male cadaver. A series of 214 upper limbs of Caucasian race was dissected. A variant artery, stemming from the very end of the axillary artery followed a superficial course distally. It passed the cubital fossa, ran on the lateral side of the forearm as usual radial artery, crossed ventrally to the palm and terminated in the deep palmar arch. This vessel is a case of the brachioradial artery (incorrectly termed as the “radial artery with high origin”. Moreover, it was associated with another variation, concerning the aberrant posterior humeral circumflex artery passing under the tendon of the latissimus dorsi muscle. The anatomical knowledge of the axillary region is essential for radiodiagnostic, surgical and traumatologic procedures. The superficially located artery brings an elevated danger of heavy bleeding in all unexpected situations, its variant branching can cause problems in radial catheterization procedures and the anomalously coursing other arterial variant poses an elevated danger in surgical procedures concerning the surgical neck of humerus.

  3. Transcatheter Splenic Artery Occlusion for Treatment of Splenic Artery Steal Syndrome After Orthotopic Liver Transplantation

    International Nuclear Information System (INIS)

    Uflacker, Renan; Selby, J. Bayne; Chavin, Kenneth; Rogers, Jeffrey; Baliga, Prabhakar

    2002-01-01

    Purpose: To review some aspects of the problem of splenic artery steal syndrome as cause of ischemia in transplanted livers and treatment by selective splenic artery occlusion. Materials and Methods: Eleven liver transplant patients from a group of 350 patients, nine men and two women,ranging in age from 40 years to 61 years (mean 52 years), presented with biochemical evidences of liver ischemia and failure, ranging from one to 60 days following orthotopic liver transplantation. Diagnosis of splenic artery steal syndrome was suspected by elevated enzymes, Doppler ultrasound and confirmed by celiac angiogram. Patients with confirmed hepatic artery thrombosis before angiography were excluded from the study. Embolization with Gianturco coils was performed. Results: All patients were treated by splenic artery embolization with Gianturco coils. The 11 patients improved clinically within 24 hours of the procedure with significant change in the biochemical and clinical parameters. Followup ranged from one month to two years. One of the 11 patient initially improved, but developed hepatic artery thrombosis within 24 hours of the embolic treatment,requiring surgical repair. Conclusion: Splenicartery steal syndrome following liver transplantation surgery can be diagnosed by celiac angiography, and effectively treated by splenic artery embolization with coils. Embolization is one of the treatments available, it is minimally invasive, and leads to immediate clinical improvement. Hepatic artery thrombosis is a possible complication of the procedure

  4. Software-defined networking control plane for seamless integration of multiple silicon photonic switches in Datacom networks.

    Science.gov (United States)

    Shen, Yiwen; Hattink, Maarten H N; Samadi, Payman; Cheng, Qixiang; Hu, Ziyiz; Gazman, Alexander; Bergman, Keren

    2018-04-16

    Silicon photonics based switches offer an effective option for the delivery of dynamic bandwidth for future large-scale Datacom systems while maintaining scalable energy efficiency. The integration of a silicon photonics-based optical switching fabric within electronic Datacom architectures requires novel network topologies and arbitration strategies to effectively manage the active elements in the network. We present a scalable software-defined networking control plane to integrate silicon photonic based switches with conventional Ethernet or InfiniBand networks. Our software-defined control plane manages both electronic packet switches and multiple silicon photonic switches for simultaneous packet and circuit switching. We built an experimental Dragonfly network testbed with 16 electronic packet switches and 2 silicon photonic switches to evaluate our control plane. Observed latencies occupied by each step of the switching procedure demonstrate a total of 344 µs control plane latency for data-center and high performance computing platforms.

  5. Task switching costs in preschool children and adults.

    Science.gov (United States)

    Peng, Anna; Kirkham, Natasha Z; Mareschal, Denis

    2018-08-01

    Past research investigating cognitive flexibility has shown that preschool children make many perseverative errors in tasks that require switching between different sets of rules. However, this inflexibility might not necessarily hold with easier tasks. The current study investigated the developmental differences in cognitive flexibility using a task-switching procedure that compared reaction times and accuracy in 4- and 6-year-olds with those in adults. The experiment involved simple target detection tasks and was intentionally designed in a way that the stimulus and response conflicts were minimal together with a long preparation window. Global mixing costs (performance costs when multiple tasks are relevant in a context), and local switch costs (performance costs due to switching to an alternative task) are typically thought to engage endogenous control processes. If this is the case, we should observe developmental differences with both of these costs. Our results show, however, that when the accuracy was good, there were no age differences in cognitive flexibility (i.e., the ability to manage multiple tasks and to switch between tasks) between children and adults. Even though preschool children had slower reaction times and were less accurate, the mixing and switch costs associated with task switching were not reliably larger for preschool children. Preschool children did, however, show more commission errors and greater response repetition effects than adults, which may reflect differences in inhibitory control. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Uterine artery chemoembolization: its application in treating cervical pregnancy

    International Nuclear Information System (INIS)

    Zhang Guofu; Shang Mingyi; Tian Xiaomei; Han Zhigang; Wang Xuezhen; Wang Dongyan; Huang Zirong; Xu Congjian

    2009-01-01

    Objective: To discuss the feasibility and safety of uterine artery chemoembolization in the treatment of cervical pregnancy. Methods: During the period of Sep. 2005-Dec. 2007, uterine artery chemoemboliztion was performed in 12 patients with cervical pregnancy in the authors' hospital. Via bilateral uterine arteries 100 mg MTX and 80,000 U Gentamycin were infused separately, after that the bilateral uterine arteries were embolized with gelfoam. Cleaning of the uterus and the cervix uteri was carried out in 24 -72 h after the procedure. Results: The technical success rate of bilateral uterine artery chemoembolization was 100%. The blood loss was 50-100 ml (mean 65 ml) during the procedure of cleaning the uterus and the cervix uteri. No serious complications occurred. Conclusion: Uterine artery chemoembolization is an effective and safe treatment for cervical pregnancy, which can greatly avoid unnecessary uterectomy and preserve fertility function. (authors)

  7. Conditions for Model Matching of Switched Asynchronous Sequential Machines with Output Feedback

    OpenAIRE

    Jung–Min Yang

    2016-01-01

    Solvability of the model matching problem for input/output switched asynchronous sequential machines is discussed in this paper. The control objective is to determine the existence condition and design algorithm for a corrective controller that can match the stable-state behavior of the closed-loop system to that of a reference model. Switching operations and correction procedures are incorporated using output feedback so that the controlled switched machine can show the ...

  8. Cerebral Ischemia Due to Traumatic Carotid Artery Dissection: Case Report

    OpenAIRE

    Deniz Kamacı Şener; Özlem Taşkapılıoğlu; Nermin Kelebek Girgin; Bahattin Hakyemez; Mustafa Bakar; Yakup Tomak

    2012-01-01

    Blunt injury to the neck region may lead to carotid artery dissection and cerebral ischemia. Blunt injury to carotid artery is not frequent but determination of the presence of trauma in the history of stroke patients will provide early diagnosis and treatment of them. In this article, a case with cerebral ischemia resulting from traumatic carotid artery dissection is presented and clinical findings, diagnostic procedures and choice of treatment are discussed in the light of the literature.

  9. Cerebral Ischemia Due to Traumatic Carotid Artery Dissection: Case Report

    Directory of Open Access Journals (Sweden)

    Deniz Kamacı Şener

    2012-12-01

    Full Text Available Blunt injury to the neck region may lead to carotid artery dissection and cerebral ischemia. Blunt injury to carotid artery is not frequent but determination of the presence of trauma in the history of stroke patients will provide early diagnosis and treatment of them. In this article, a case with cerebral ischemia resulting from traumatic carotid artery dissection is presented and clinical findings, diagnostic procedures and choice of treatment are discussed in the light of the literature.

  10. 大动脉调转术后儿童母亲亲职压力和心理状态的对照研究%Case-control study in parenting stress and mental state in mothers of children after arterial switch operation

    Institute of Scientific and Technical Information of China (English)

    曾小璐; 邹小兵; 岑超群; 钟敏泉

    2011-01-01

    [目的]探讨大动脉调转术后儿童与正常儿童母亲的亲职压力和心理状况,为术后儿童的全面康复提供数据. [方法]采用亲职压力指标简表(Parenting Stress Index Short Form,PSI/SF)、状态-特质焦虑量表(State-Trait Anxiety InventorY,STAI)对135例大动脉调转术后儿童的母亲和142例正常儿童的母亲进行调查. [结果]大动脉调转术后儿童的母亲亲职压力量表总分、亲职愁苦及亲子互动失调分量表得分高于正常对照组[总分(93.49±15.10)vs(74.71±16.55),P<0.05],状态焦虑得分高于正常对照组[(43.19±7.07)vs(39.67±7.45),P<0.053,亲职压力量表总分及亲职愁苦分量表得分与状态焦虑得分呈正相关. [结论]大动脉调转术后儿童母亲存在较高水平的亲职压力和状态焦虑,值得专业人员关注和实施干预.%[Objective] To explore parenting stress and mental state in mothers of children after arterial switch operation(ASO)and children with normal development,presenting information for comprehensive rehabilitation of children accepting operation in infancy. [Methods] A total of 135 mothers of children who undergone ASO were investigated with the Parenting Stress Index Short Form (PSI / SF), State-Trait Anxiety Inventory(STAI). Their scores were compared with that of 142 mothers with healthy children. [Results] Mothers of children after ASO exprienced a significantly higher level in the total score of parenting stress and subscale score of parental distress and parent-child dysfunctional interaction as compared with mothers of healthy children[ the total score(93. 49 ± 15. 10) vs(74. 71 ± 16.55), P< 0.05 ]. In terms of the STAI, we found mothers of children after ASO) have higher SAI scores[ (43. 19± 7. 07)vs(39.67 ±7. 45 ), P< 0. 05 ] which were correlated with total parenting stress and parental distress. [Conclusions] Mothers of children undergone ASO generally experience more parenting stress and state anxiety than

  11. Embolization of a large, symptomatic splenic artery pseudoaneurysm

    International Nuclear Information System (INIS)

    Kukliński, Adam; Batycki, Krzysztof; Matuszewski, Wiesław; Ostrach, Andrzej; Kupis, Zbigniew; Łęgowik, Tomasz

    2014-01-01

    Splenic artery aneurysm is the third most common abdominal aneurysm. Most often it is due to pancreatitis. There were only 19 cases of aneurysms larger than 5 cm in diameter described in the literature. Management of splenic artery aneurysms depends on the size and symptoms. Invasive treatment modalities involve open procedures and interventional radiology methods (endovascular). A 44-years-old male with chronic pancreatitis, in a gradually worsening general condition due to a large splenic artery aneurysm, was subjected to the procedure. Blood flow through the aneurysm was cut-off by implanting a covered stent between celiac trunk and common hepatic artery. Patient’s general condition rapidly improved, allowing discharge home in good state soon after the procedure. Percutaneous embolization appears to be the best method of treatment of large splenic artery aneurysms. Complications of such treatment are significantly less dangerous than those associated with surgery

  12. MENGAPA PERUSAHAAN MELAKUKAN AUDITOR SWITCH?

    Directory of Open Access Journals (Sweden)

    Kadek Sumadi

    2011-01-01

    Full Text Available The existence of a large number of accounting firms allowsprovides companies choices whether to stay with current firm or switchto another accounting firm. Decision of Minister of FinanceNo.423/KMK.06/2002 states that a company must switch auditor afterfive years of consecutive assignment. This is mandatory. The questionrises when a company voluntarily switches its auditor. Why does thishappen?One of the reasons is that management does not satisfy withauditor opinion, except for unqualified opinion. New management teamwould directly or indirectly encourage auditor switch to align accountingand reporting policies. Moreover an expanding company expects positivereaction when it does auditor switch. Profitability is also one reason fora company to switch auditor, for example, when a company earns moreprofit it tends to hire more credible auditor. On the other hand, when thecompany faces a financial distress, it probably would switch auditor aswell.

  13. Low-Crosstalk Composite Optical Crosspoint Switches

    Science.gov (United States)

    Pan, Jing-Jong; Liang, Frank

    1993-01-01

    Composite optical switch includes two elementary optical switches in tandem, plus optical absorbers. Like elementary optical switches, composite optical switches assembled into switch matrix. Performance enhanced by increasing number of elementary switches. Advantage of concept: crosstalk reduced to acceptably low level at moderate cost of doubling number of elementary switches rather than at greater cost of tightening manufacturing tolerances and exerting more-precise control over operating conditions.

  14. Parent artery occlusion for ruptured "true" posterior communicating artery aneurysm.

    Science.gov (United States)

    Mitsuhashi, Takashi; Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-04-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgical clipping over endovascular coil embolization. Endovascular treatment may be a good alternative to surgical trapping for true PCoA blister aneurysm. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Compound semiconductor optical waveguide switch

    Science.gov (United States)

    Spahn, Olga B.; Sullivan, Charles T.; Garcia, Ernest J.

    2003-06-10

    An optical waveguide switch is disclosed which is formed from III-V compound semiconductors and which has a moveable optical waveguide with a cantilevered portion that can be bent laterally by an integral electrostatic actuator to route an optical signal (i.e. light) between the moveable optical waveguide and one of a plurality of fixed optical waveguides. A plurality of optical waveguide switches can be formed on a common substrate and interconnected to form an optical switching network.

  16. Hepatic artery aneurysms (HAAs)

    International Nuclear Information System (INIS)

    Nosratini, H.

    2004-01-01

    The hepatic artery aneurysms are rare, especially in interahepatic branches, The frequency consists of 75-80% extrahepatic and 20-25% intrahepatic. Catheterization is achieved usually from common femoral artery, other methods implemented in the case of unsuccessful catheterization from femoral artery, are translumbar and brachial catheterization. The study consist of 565 patients that were referred to the angiography ward, During seven years of assessment, five cases of hepatic artery aneurysm were found; this is a rare condition reported in the English literature. In the literature as well as in this case report the hepatic artery aneurysms are rare. In reported series the extrahepatic artery aneurysms are found more often than in the intrahepatic artery aneurysm but in this case report intrahepatic artery aneurysms are more than extrahepatic one. (author)

  17. Neuromorphic atomic switch networks.

    Directory of Open Access Journals (Sweden)

    Audrius V Avizienis

    Full Text Available Efforts to emulate the formidable information processing capabilities of the brain through neuromorphic engineering have been bolstered by recent progress in the fabrication of nonlinear, nanoscale circuit elements that exhibit synapse-like operational characteristics. However, conventional fabrication techniques are unable to efficiently generate structures with the highly complex interconnectivity found in biological neuronal networks. Here we demonstrate the physical realization of a self-assembled neuromorphic device which implements basic concepts of systems neuroscience through a hardware-based platform comprised of over a billion interconnected atomic-switch inorganic synapses embedded in a complex network of silver nanowires. Observations of network activation and passive harmonic generation demonstrate a collective response to input stimulus in agreement with recent theoretical predictions. Further, emergent behaviors unique to the complex network of atomic switches and akin to brain function are observed, namely spatially distributed memory, recurrent dynamics and the activation of feedforward subnetworks. These devices display the functional characteristics required for implementing unconventional, biologically and neurally inspired computational methodologies in a synthetic experimental system.

  18. Software Switching for Data Acquisition

    CERN Multimedia

    CERN. Geneva; Malone, David

    2016-01-01

    In this talk we discuss the feasibility of replacing telecom-class routers with a topology of commodity servers acting as software switches in data acquisition. We extend the popular software switch, Open vSwitch, with a dedicated, throughput-oriented buffering mechanism. We compare the performance under heavy many-to-one congestion to typical Ethernet switches and evaluate the scalability when building larger topologies, exploiting the integration with software-defined networking technologies. Please note that David Malone will speak on behalf of Grzegorz Jereczek.

  19. Context Switching with Multiple Register Windows: A RISC Performance Study

    Science.gov (United States)

    Konsek, Marion B.; Reed, Daniel A.; Watcharawittayakul, Wittaya

    1987-01-01

    Although previous studies have shown that a large file of overlapping register windows can greatly reduce procedure call/return overhead, the effects of register windows in a multiprogramming environment are poorly understood. This paper investigates the performance of multiprogrammed, reduced instruction set computers (RISCs) as a function of window management strategy. Using an analytic model that reflects context switch and procedure call overheads, we analyze the performance of simple, linearly self-recursive programs. For more complex programs, we present the results of a simulation study. These studies show that a simple strategy that saves all windows prior to a context switch, but restores only a single window following a context switch, performs near optimally.

  20. Bilateral renal artery variation

    OpenAIRE

    Üçerler, Hülya; Üzüm, Yusuf; İkiz, Z. Aslı Aktan

    2014-01-01

    Each kidney is supplied by a single renal artery, although renal artery variations are common. Variations of the renal arteryhave become important with the increasing number of renal transplantations. Numerous studies describe variations in renalartery anatomy. Especially the left renal artery is among the most critical arterial variations, because it is the referred side forresecting the donor kidney. During routine dissection in a formalin fixed male cadaver, we have found a bilateral renal...

  1. 78 FR 26110 - Kicking Cars and Going Between Rolling Equipment During Flat Switching Operations

    Science.gov (United States)

    2013-05-03

    ... Cars and Going Between Rolling Equipment During Flat Switching Operations AGENCY: Federal Railroad... occurred during a railroad switching operation that involved a railroad employee kicking cars and... make recommendations to railroads regarding the adoption of car-handling procedures during flat...

  2. Aortic homograft for pulmonary artery augmentation in single lung transplantation.

    Science.gov (United States)

    Rueda, Pablo; Morales, Jose; Guzman, Enrique; Tellez, Jose L; Niebla, Benito A; Avalos, Alejandro; Patiño, Hilda

    2005-06-01

    We present a case of unilateral lung transplantation in which a segment of the donor's descending aorta was used as a homograft for pulmonary artery augmentation in the donor lung. This technique can be used when the donor's lung artery has been cut at the base of the hilum during the harvesting procedure.

  3. Transcatheter arterial embolization for traumatic bleeding control

    International Nuclear Information System (INIS)

    Ryu, Choon Wook; Lee, Sang Kwon; Suh, Kyung Jin; Kim, Tae Heon; Kim, Yong Joo; Kang, Duck Sik

    1989-01-01

    Angiography is essential for the detection of bleeding vessels in traumatic vascular injury. Immediately after the diagnosis, transcatheter embolization can be performed for the control of bleeding effectively and easily with proper use of embolic materials. Transcatheter embolization is believed to be the treatment of choice when emergency control is needed, where surgical approach is difficult and in those who are poor candidate for surgery. We have tried bleeding control in 18 cases of trauma over recent 4 years. The results were as follows; 1. Causes of bleeding(cases): Blunt or penetrating trauma (10), latrogenic trauma (8), (Postoperative (5), Needle biopsy (2), Percutaneous hepatic procedure (1)) 2. Embolized vessels: Renal artery branches (8), Hepatic artery branches (2), Arteries supplying chest wall (2), External carotid artery branches (3), Internal carotid artery (1), Circumflex humeral artery (1), Internal iliac artery branches (1). 3. Embolic agents: Gelfoam cubes (16), Stainless steel coils (3), Detachable latex balloon (1). 4. Successful bleeding control was achieved in 17 cases and reduction of the amount of bleeding in one case without significant complications

  4. Variant facial artery in the submandibular region.

    Science.gov (United States)

    Vadgaonkar, Rajanigandha; Rai, Rajalakshmi; Prabhu, Latha V; Bv, Murlimanju; Samapriya, Neha

    2012-07-01

    Facial artery has been considered to be the most important vascular pedicle in facial rejuvenation procedures and submandibular gland (SMG) resection. It usually arises from the external carotid artery and passes from the carotid to digastric triangle, deep to the posterior belly of digastric muscle, and lodges in a groove at the posterior end of the SMG. It then passes between SMG and the mandible to reach the face after winding around the base of the mandible. During a routine dissection, in a 62-year-old female cadaver, in Kasturba Medical College Mangalore, an unusual pattern in the cervical course of facial artery was revealed. The right facial artery was found to pierce the whole substance of the SMG before winding around the lower border of the mandible to enter the facial region. Awareness of existence of such a variant and its comparison to the normal anatomy will be useful to oral and maxillofacial surgeons.

  5. Incidence and Potential Mechanism(s) of Post-Procedural Rise of Cardiac Biomarker in Patients With Coronary Artery Narrowing After Implantation of an Everolimus-Eluting Bioresorbable Vascular Scaffold or Everolimus-Eluting Metallic Stent

    DEFF Research Database (Denmark)

    Ishibashi, Yuki; Muramatsu, Takashi; Nakatani, Shimpei

    2015-01-01

    OBJECTIVES: This study sought to evaluate the mechanism of post-procedural cardiac biomarker (CB) rise following device implantation. BACKGROUND: A fully bioresorbable Absorb scaffold, compared with everolimus-eluting metallic stents (EES), might be associated with a higher incidence...

  6. Hybrid switch for resonant power converters

    Science.gov (United States)

    Lai, Jih-Sheng; Yu, Wensong

    2014-09-09

    A hybrid switch comprising two semiconductor switches connected in parallel but having different voltage drop characteristics as a function of current facilitates attainment of zero voltage switching and reduces conduction losses to complement reduction of switching losses achieved through zero voltage switching in power converters such as high-current inverters.

  7. LCT protective dump-switch tests

    International Nuclear Information System (INIS)

    Parsons, W.M.

    1981-01-01

    Each of the six coils in the Large Coil Task (LCT) has a separate power supply, dump resistor, and switching circuit. Each switching circuit contains five switches, two of which are redundant. The three remaining switches perform separate duties in an emergency dump situation. These three switches were tested to determine their ability to meet the LCT conditions

  8. Percutaneous microcrystalline chitosan application for sealing arterial puncture sites

    NARCIS (Netherlands)

    Hoekstra, A; Struszczyk, H; Kivekas, O

    Arterial catheterization is one of the most frequently performed inpatient diagnostic and therapeutic procedures in the development countries. Complications may occur after any catheterization from inadequate hemostasis, particularly in the setting of aggressive anticoagulation. This study suggests

  9. EDITORIAL: Molecular switches at surfaces Molecular switches at surfaces

    Science.gov (United States)

    Weinelt, Martin; von Oppen, Felix

    2012-10-01

    In nature, molecules exploit interaction with their environment to realize complex functionalities on the nanometer length scale. Physical, chemical and/or biological specificity is frequently achieved by the switching of molecules between microscopically different states. Paradigmatic examples are the energy production in proton pumps of bacteria or the signal conversion in human vision, which rely on switching molecules between different configurations or conformations by external stimuli. The remarkable reproducibility and unparalleled fatigue resistance of these natural processes makes it highly desirable to emulate nature and develop artificial systems with molecular functionalities. A promising avenue towards this goal is to anchor the molecular switches at surfaces, offering new pathways to control their functional properties, to apply electrical contacts, or to integrate switches into larger systems. Anchoring at surfaces allows one to access the full range from individual molecular switches to self-assembled monolayers of well-defined geometry and to customize the coupling between molecules and substrate or between adsorbed molecules. Progress in this field requires both synthesis and preparation of appropriate molecular systems and control over suitable external stimuli, such as light, heat, or electrical currents. To optimize switching and generate function, it is essential to unravel the geometric structure, the electronic properties and the dynamic interactions of the molecular switches on surfaces. This special section, Molecular Switches at Surfaces, collects 17 contributions describing different aspects of this research field. They analyze elementary processes, both in single molecules and in ensembles of molecules, which involve molecular switching and concomitant changes of optical, electronic, or magnetic properties. Two topical reviews summarize the current status, including both challenges and achievements in the field of molecular switches on

  10. Circuit switched optical networks

    DEFF Research Database (Denmark)

    Kloch, Allan

    2003-01-01

    Some of the most important components required for enabling optical networking are investigated through both experiments and modelling. These all-optical components are the wavelength converter, the regenerator and the space switch. When these devices become "off-the-shelf" products, optical cross......, it is expected that the optical solution will offer an economical benefit for hight bit rate networks. This thesis begins with a discussion of the expected impact on communications systems from the rapidly growing IP traffic, which is expected to become the dominant source for traffic. IP traffic has some...... characteristics, which are best supported by an optical network. The interest for such an optical network is exemplified by the formation of the ACTS OPEN project which aim was to investigate the feasibility of an optical network covering Europe. Part of the work presented in this thesis is carried out within...

  11. Photo-switching element

    Energy Technology Data Exchange (ETDEWEB)

    Masaki, Yuichi

    1987-10-31

    Photo-input MOS transistor (Photo-switching element) cannot give enough ON/OFF ratio but requires an auxiliary condenser for a certain type of application. In addition, PN junction of amorphous silicon is not practical because it gives high leak current resulting in low electromotive force. In this invention, a solar cell was constructed with a lower electrode consisting of a transparent electro-conducting film, a photosensitive part consisting of an amorphous Si layer of p-i-n layer construction, and an upper metal electrode consisting of Cr or Nichrome, and a thin film transistor was placed on the solar cell, and further the upper metal electrode was co-used as a gate electrode of the thin film transistor; this set-up of this invention enabled to attain an efficient photo-electric conversion of the incident light, high electromotive force of the solar cell, and the transistor with high ON/OFF ratio. (3 figs)

  12. Battery switch for downhole tools

    Science.gov (United States)

    Boling, Brian E.

    2010-02-23

    An electrical circuit for a downhole tool may include a battery, a load electrically connected to the battery, and at least one switch electrically connected in series with the battery and to the load. The at least one switch may be configured to close when a tool temperature exceeds a selected temperature.

  13. Improved switch-resistor packaging

    Science.gov (United States)

    Redmerski, R. E.

    1980-01-01

    Packaging approach makes resistors more accessible and easily identified with specific switches. Failures are repaired more quickly because of improved accessibility. Typical board includes one resistor that acts as circuit breaker, and others are positioned so that their values can be easily measured when switch is operated. Approach saves weight by using less wire and saves valuable panel space.

  14. Superconductivity, energy storage and switching

    International Nuclear Information System (INIS)

    Laquer, H.L.

    1974-01-01

    The phenomenon of superconductivity can contribute to the technology of energy storage and switching in two distinct ways. On one hand the zero resistivity of the superconductor can produce essentially infinite time constants so that an inductive storage system can be charged from very low power sources. On the other hand, the recovery of finite resistivity in a normal-going superconducting switch can take place in extremely short times, so that a system can be made to deliver energy at a very high power level. Topics reviewed include: physics of superconductivity, limits to switching speed of superconductors, physical and engineering properties of superconducting materials and assemblies, switching methods, load impedance considerations, refrigeration economics, limitations imposed by present day and near term technology, performance of existing and planned energy storage systems, and a comparison with some alternative methods of storing and switching energy. (U.S.)

  15. Amorphous metal based nanoelectromechanical switch

    KAUST Repository

    Mayet, Abdulilah M.; Smith, Casey; Hussain, Muhammad Mustafa

    2013-01-01

    Nanoelectromechanical (NEM) switch is an interesting ultra-low power option which can operate in the harsh environment and can be a complementary element in complex digital circuitry. Although significant advancement is happening in this field, report on ultra-low voltage (pull-in) switch which offers high switching speed and area efficiency is yet to be made. One key challenge to achieve such characteristics is to fabricate nano-scale switches with amorphous metal so the shape and dimensional integrity are maintained to achieve the desired performance. Therefore, we report a tungsten alloy based amorphous metal with fabrication process development of laterally actuated dual gated NEM switches with 100 nm width and 200 nm air-gap to result in <5 volts of actuation voltage (Vpull-in). © 2013 IEEE.

  16. Amorphous metal based nanoelectromechanical switch

    KAUST Repository

    Mayet, Abdulilah M.

    2013-04-01

    Nanoelectromechanical (NEM) switch is an interesting ultra-low power option which can operate in the harsh environment and can be a complementary element in complex digital circuitry. Although significant advancement is happening in this field, report on ultra-low voltage (pull-in) switch which offers high switching speed and area efficiency is yet to be made. One key challenge to achieve such characteristics is to fabricate nano-scale switches with amorphous metal so the shape and dimensional integrity are maintained to achieve the desired performance. Therefore, we report a tungsten alloy based amorphous metal with fabrication process development of laterally actuated dual gated NEM switches with 100 nm width and 200 nm air-gap to result in <5 volts of actuation voltage (Vpull-in). © 2013 IEEE.

  17. Thyrocervical artery - jugular fistula following internal jugular venous catheterization

    Directory of Open Access Journals (Sweden)

    P P Zachariah

    2014-01-01

    Full Text Available Arteriovenous fistula (AVF is an anomalous communication between an artery and a vein, caused by an iatrogenic or traumatic etiology. Surgically created upper limb AVF remains the preferred vascular access for patients on maintenance hemodialysis. Nonetheless central vein cannulation for hemodialysis is a common procedure done in patients who need hemodialysis. We incidentally detected a thyrocervical artery - jugular fistula in a patient on maintenance hemodialysis. He underwent a successful intra arterial coil embolization of the feeding vessel. Review of literature has shown that, a thyrocervical artery - internal jugular vein arteriovenous fistula following a central venous catheterization has not been reported so far.

  18. Production of fast switching power thyristors by proton irradiation

    International Nuclear Information System (INIS)

    Sawko, D.C.; Bartko, J.

    1983-01-01

    There are several techniques currently employed by various manufacturers in the fabrication of fast switching power thyristors. Gold doping and irradiation by electron beams are among the more common ones. In all cases, the fast switching capability results from a reduction of the minority carrier lifetime of the host material by the introduction of carrier traps or recombination centers. However, accompanying this beneficial reduction in switching speed is a deleterious increase in forward voltage drop which also results from the introduction of carrier traps. Methods which minimize the voltage drop increase as the switching speed is reduced are highly desirable. One such method would achieve this by introducing the traps or recombination centers into well defined narrow regions where they will be more effective in reducing the switching speed than in increasing the forward voltage drop. Because the proton range-energy relationship in materials is relatively well defined and the lifetime reducing displacements occur near the end of their ranges, the lifetime in silicon can be reduced where desired by the precise control of proton energy. Dual energy proton beams from a tandem Van de Graaff accelerator were used in the experiments to determine whether proton beam irradiations offer advantages over other techniques. This was the subject of the present work. The results indicate that this is the preferred technique for reproducibly and rapidly processing fast switching thyristors with superior characteristics. The experimental procedure is discussed and comparisons are made with electron and neutron irradiated thyristors

  19. Switching Phenomena in a System with No Switches

    Science.gov (United States)

    Preis, Tobias; Stanley, H. Eugene

    2010-02-01

    It is widely believed that switching phenomena require switches, but this is actually not true. For an intriguing variety of switching phenomena in nature, the underlying complex system abruptly changes from one state to another in a highly discontinuous fashion. For example, financial market fluctuations are characterized by many abrupt switchings creating increasing trends ("bubble formation") and decreasing trends ("financial collapse"). Such switching occurs on time scales ranging from macroscopic bubbles persisting for hundreds of days to microscopic bubbles persisting only for a few seconds. We analyze a database containing 13,991,275 German DAX Future transactions recorded with a time resolution of 10 msec. For comparison, a database providing 2,592,531 of all S&P500 daily closing prices is used. We ask whether these ubiquitous switching phenomena have quantifiable features independent of the time horizon studied. We find striking scale-free behavior of the volatility after each switching occurs. We interpret our findings as being consistent with time-dependent collective behavior of financial market participants. We test the possible universality of our result by performing a parallel analysis of fluctuations in transaction volume and time intervals between trades. We show that these financial market switching processes have properties similar to those of phase transitions. We suggest that the well-known catastrophic bubbles that occur on large time scales—such as the most recent financial crisis—are no outliers but single dramatic representatives caused by the switching between upward and downward trends on time scales varying over nine orders of magnitude from very large (≈102 days) down to very small (≈10 ms).

  20. Surgical revascularization of posterior coronary arteries without cardiopulomonary bypass

    Directory of Open Access Journals (Sweden)

    Lobo Filho J. Glauco

    1999-01-01

    Full Text Available OBJECTIVE: To assess the results observed during the early postoperative period in patients who had the posterior coronary arteries revascularized without cardiopulmonary bypass (CPB, in regard to the following parameters: age, sex,bypass grafts types, morbidity and mortality. METHODS: From January 1995 to June 1998, 673 patients underwent myocardial revascularization (MR. Of this total, 607 (90.20% MR procedures were performed without CPB. The posterior coronary arteries (PCA were revascularized in 298 (44.27% patients, 280 (93.95% without CPB. The age of the patients ranged from 37 to 88 years (mean, 61 years. The male gender predominated, with 198 men (70.7%. The revascularization of the posterior coronary arteries had the following distribution: diagonalis artery (31 patients, 10%; marginal branches of the circumflex artery (243 patients, 78.7%; posterior ventricular artery (4 patients, 1.3%; and posterior descending artery (31 patients, 10%. RESULTS: Procedure-related complications without death occurred in 7 cases, giving a morbidity of 2.5%. There were 11 deaths in the early postoperative period (mortality of 3.9%. CONCLUSION: Similarly to the anterior coronary arteries, the posterior coronary arteries may benefit from myocardial revascularization without CPB.

  1. Accessory Meningeal Arterial Supply to the Posterior Nasal Cavity: Another Reason for Failed Endovascular Treatment of Epistaxis

    International Nuclear Information System (INIS)

    Duncan, I.C.; Santos, C. Dos

    2003-01-01

    A patient with intractable posterior epistaxis was treated with embolization of the ipsilateral sphenopalatine and facial arteries and contralateral sphenopalatine artery. She continued to bleed despite a seemingly adequate embolization procedure. A second angiogram revealed a significant collateral blood supply to the posterior nasal cavity from the accessory meningeal artery not identified during the first procedure. This was then embolized with no further epistaxis encountered. This case demonstrates yet another collateral arterial pathway that might account for a failed embolization

  2. Optimization of Modulation Waveforms for Improved EMI Attenuation in Switching Frequency Modulated Power Converters

    Directory of Open Access Journals (Sweden)

    Deniss Stepins

    2015-01-01

    Full Text Available Electromagnetic interference (EMI is one of the major problems of switching power converters. This paper is devoted to switching frequency modulation used for conducted EMI suppression in switching power converters. Comprehensive theoretical analysis of switching power converter conducted EMI spectrum and EMI attenuation due the use of traditional ramp and multislope ramp modulation waveforms is presented. Expressions to calculate EMI spectrum and attenuation are derived. Optimization procedure of the multislope ramp modulation waveform is proposed to get maximum benefits from switching frequency modulation for EMI reduction. Experimental verification is also performed to prove that the optimized multislope ramp modulation waveform is very useful solution for effective EMI reduction in switching power converters.

  3. "The challenge facing renal artery revascularization: what have we not proven and why we must"?

    LENUS (Irish Health Repository)

    Hynes, B G

    2012-01-04

    Endovascular renal artery stent therapy for atherosclerotic renal artery stenosis (RAS) is associated with excellent acute technical success, low complication rates and acceptable long-term patency. However, the clinical benefits to patients of renal artery stenting remain uncertain. To facilitate debate regarding the treatment of RAS, we need to understand the epidemiology, basic physiology and clinical consequences of renal artery stenosis. We must attempt to determine which patients are likely to benefit from renal artery stenting, assess the nuances of the percutaneous procedure and review the current literature pertaining to renal artery stenting.

  4. Quantization Procedures

    International Nuclear Information System (INIS)

    Cabrera, J. A.; Martin, R.

    1976-01-01

    We present in this work a review of the conventional quantization procedure, the proposed by I.E. Segal and a new quantization procedure similar to this one for use in non linear problems. We apply this quantization procedures to different potentials and we obtain the appropriate equations of motion. It is shown that for the linear case the three procedures exposed are equivalent but for the non linear cases we obtain different equations of motion and different energy spectra. (Author) 16 refs

  5. MR angiography and the preoperative evaluation of renal arteries

    International Nuclear Information System (INIS)

    Nakahara, Kimitoshi; Yokoyama, Hiroshi; Tsuji, Yuji

    2001-01-01

    To determine the accuracy of gadolinium-enhanced, three-dimensional, magnetic resonance angiography (3D-MRA) in the visualization of the arterial anatomy of the kidney, we compared preoperative 3D-MRA results with surgical findings in 37 patients who underwent renal surgery. 3D-MRA findings were confirmed surgically in 30 of these patients (81%). However, 4 of 7 accessory renal arteries were missed by this imaging technique. Furthermore, 3D-MRA failed to visualize renal arteries in all of the three atrophic kidneys. 3D-MRA is a safe and reliable procedure for the preoperative evaluation of renal arteries. However, the depiction of smaller renal arteries, such as accessory and atrophic arteries, is less accurate. (author)

  6. Myocardial Infarction as a Complication of Bronchial Artery Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Labbé, Hugo, E-mail: hugo.labbe.1@ulaval.ca [Université Laval, Department of Medicine (Canada); Bordeleau, Simon [Université Laval, Department of Emergency Medicine (Canada); Drouin, Christine [Université Laval, Department of Anesthesiology and Critical Care Medicine (Canada); Archambault, Patrick [Université Laval, Department of Emergency Medicine (Canada)

    2017-03-15

    Bronchial artery embolization is now a common treatment for massive pulmonary hemoptysis if flexible bronchoscopy at the bedside failed to control the bleeding. Complications of this technique range from benign chest pain to devastating neurological impairments. We report the case of a 41-year-old man who developed an ST elevation myocardial infarction during bronchial artery embolization, presumably because of coronary embolism by injected particles. In this patient who had no previously known coronary artery disease, we retrospectively found a communication between the left bronchial artery and the circumflex coronary artery. This fistula was not visible on the initial angiographic view and likely opened because of the hemodynamic changes resulting from the embolization. This case advocates for careful search for bronchial-to-coronary arterial fistulas and the need for repeated angiographic views during embolization procedures.

  7. Prevention and treatment of complications for thyroid-arterial embolization

    International Nuclear Information System (INIS)

    Yang Jijin; Yuan Min; Tian Jianming; Chen Wei; Yang Chaoai; Hao Qiang; Zou Dajing; Wang Yongchun

    2003-01-01

    Objective: To investigate the complications of thyroid-arterial embolization and their prevention and treatment. Methods: 61 cases of thyroid disorders received the therapy of thyroid-arterial embolization were retrospectively studied. The complications of arterial embolization during or after the procedure were analyzed. How to prevent and deal with these complications were discussed. Results: Sensitivity to contrast media occurred in 1 case and surgical arterial injury in 2. After embolization thyroid storm occurred in 1 patient and all other complications including headache (23 cases), toothache (11 cases), neckache (13 cases), hoarseness (37 cases) were caused by non-target arterial embolization with the most serious one of cerebral infarction (1 case) and another eyelid ptosis (1 case). The cerebral infarct one was treated with some vasodilating drugs and anti-coagulant, all others were given anti-symptomatics or no special treatment. Conclusions: Proper treatment should be ready during thyroid arterial embolization and given in time with occurrence of complications

  8. MR angiography and the preoperative evaluation of renal arteries

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, Kimitoshi; Yokoyama, Hiroshi; Tsuji, Yuji [Fukuoka Univ. (Japan). School of Medicine

    2001-04-01

    To determine the accuracy of gadolinium-enhanced, three-dimensional, magnetic resonance angiography (3D-MRA) in the visualization of the arterial anatomy of the kidney, we compared preoperative 3D-MRA results with surgical findings in 37 patients who underwent renal surgery. 3D-MRA findings were confirmed surgically in 30 of these patients (81%). However, 4 of 7 accessory renal arteries were missed by this imaging technique. Furthermore, 3D-MRA failed to visualize renal arteries in all of the three atrophic kidneys. 3D-MRA is a safe and reliable procedure for the preoperative evaluation of renal arteries. However, the depiction of smaller renal arteries, such as accessory and atrophic arteries, is less accurate. (author)

  9. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  10. DETERMINANT OF DOWNWARD AUDITOR SWITCHING

    Directory of Open Access Journals (Sweden)

    Totok Budisantoso

    2017-12-01

    Full Text Available Abstract: Determinant of Downward Auditor Switching. This study examines the factors that influence downward auditor switching in five ASEAN countries. Fixed effect logistic regression was used as analytical method. This study found that opinion shopping occurred in ASEAN, especially in distress companies. Companies with complex businesses will retain the Big Four auditors to reduce complexity and audit costs. Audit and public committees serve as guardians of auditor quality. On the other hand, shareholders failed to maintain audit quality. It indicates that there is entrenchment effect in auditor switching.

  11. Electrically switched ion exchange

    Energy Technology Data Exchange (ETDEWEB)

    Lilga, M.A. [Pacific Northwest National Lab., Richland, WA (United States); Schwartz, D.T.; Genders, D.

    1997-10-01

    A variety of waste types containing radioactive {sup 137}Cs are found throughout the DOE complex. These waste types include water in reactor cooling basins, radioactive high-level waste (HLW) in underground storage tanks, and groundwater. Safety and regulatory requirements and economics require the removal of radiocesium before these wastes can be permanently disposed of. Electrically Switched Ion Exchange (ESIX) is an approach for radioactive cesium separation that combines IX and electrochemistry to provide a selective, reversible, and economic separation method that also produces little or no secondary waste. In the ESIX process, an electroactive IX film is deposited electrochemically onto a high-surface area electrode, and ion uptake and elution are controlled directly by modulating the potential of the film. For cesium, the electroactive films under investigation are ferrocyanides, which are well known to have high selectivities for cesium in concentrated sodium solutions. When a cathode potential is applied to the film, Fe{sup +3} is reduced to the Fe{sup +2} state, and a cation must be intercalated into the film to maintain charge neutrality (i.e., Cs{sup +} is loaded). Conversely, if an anodic potential is applied, a cation must be released from the film (i.e., Cs{sup +} is unloaded). Therefore, to load the film with cesium, the film is simply reduced; to unload cesium, the film is oxidized.

  12. Analysis, reconstruction and manipulation using arterial snakes

    KAUST Repository

    Li, Guo

    2010-01-01

    Man-made objects often consist of detailed and interleaving structures, which are created using cane, coils, metal wires, rods, etc. The delicate structures, although manufactured using simple procedures, are challenging to scan and reconstruct. We observe that such structures are inherently 1D, and hence are naturally represented using an arrangement of generating curves. We refer to the resultant surfaces as arterial surfaces. In this paper we approach for analyzing, reconstructing, and manipulating such arterial surfaces. The core of the algorithm is a novel deformable model, called arterial snake, that simultaneously captures the topology and geometry of the arterial objects. The recovered snakes produce a natural decomposition of the raw scans, with the decomposed parts often capturing meaningful object sections. We demonstrate the robustness of our algorithm on a variety of arterial objects corrupted with noise, outliers, and with large parts missing. We present a range of applications including reconstruction, topology repairing, and manipulation of arterial surfaces by directly controlling the underlying curve network and the associated sectional profiles, which are otherwise challenging to perform. © 2010 ACM.

  13. Kissing stenting of aorto-ostial lesions in juxtaposed renal arteries

    OpenAIRE

    Hasija, Pradeep; Chadha, Davinder; Kalra, Ravi

    2014-01-01

    Percutaneous angioplasty with or without stenting has become an established procedure for treatment of renal artery stenosis for control of hypertension or progressive renal dysfunction. Anatomic variation of renal arteries is common with dual blood supply of unilateral kidney noted in almost 25% of the general population. Renal angioplasty of these anatomic variants of renal arteries is challenging. We present an unusual case of juxtaposed renal arteries with aorto-ostial lesion where direct...

  14. Duplicated middle cerebral artery

    Science.gov (United States)

    Perez, Jesus; Machado, Calixto; Scherle, Claudio; Hierro, Daniel

    2009-01-01

    Duplicated middle cerebral artery (DMCA) is an anomalous vessel arising from the internal carotid artery. The incidence DMCA is relatively law, and an association between this anomaly and cerebral aneurysms has been documented. There is a controversy whether DMCA may have perforating arteries. This is an important fact to consider in aneurysm surgery. We report the case of a 34-year-old black woman who suffered a subarachnoid hemorrhage and the angiography a left DMCA, and an aneurysm in an inferior branch of the main MCA. The DMCA and the MCA had perforating arteries. The aneurysm was clipped without complications. The observation of perforating arteries in our patient confirms that the DMCA may have perforating arteries. This is very important to be considered in cerebral aneurysms surgery. Moreover, the DMCA may potentially serve as a collateral blood supply to the MCA territory in cases of MCA occlusion. PMID:22140405

  15. Endovascular repair of blunt popliteal arterial injuries

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Shan; Zhang, Xiquan; Chen, Zhong; Zhu, Wei; Pan, Xiaolin [Dept. of nterventional Vascular, The 148th Hospital of Chinese People' s Liberation Army, Zibo (China); Dong, Peng; Sun, Yequan [Dept. of Medical Imaging, Weifang Medical University, Weifang (China); Qi, Deming [Dept. of Medical Imaging, Qilu Medical University, Zibo (China)

    2016-09-15

    To evaluate the feasibility and effectiveness of endovascular repair for blunt popliteal arterial injuries. A retrospective analysis of seven patients with clinical suspicion of popliteal arterial injuries that were confirmed by arteriography was performed from September 2009 to July 2014. Clinical data included demographics, mechanism of injury, type of injury, location of injury, concomitant injuries, time of endovascular procedures, time interval from trauma to blood flow restoration, instrument utilized, and follow-up. All patients were male (mean age of 35.9 ± 10.3 years). The type of lesion involved intimal injury (n = 1), partial transection (n = 2), complete transection (n = 2), arteriovenous fistula (n = 1), and pseudoaneurysm (n = 1). All patients underwent endovascular repair of blunt popliteal arterial injuries. Technical success rate was 100%. Intimal injury was treated with a bare-metal stent. Pseudoaneurysm and popliteal artery transections were treated with bare-metal stents. Arteriovenous fistula was treated with bare-metal stent and coils. No perioperative death and procedure-related complication occurred. The average follow-up was 20.9 ± 2.3 months (range 18–24 months). One patient underwent intra-arterial thrombolysis due to stent thrombosis at 18 months after the procedure. All limbs were salvaged. Stent migration, deformation, or fracture was not found during the follow-up. Endovascular repair seems to be a viable approach for patients with blunt popliteal arterial injuries, especially on an emergency basis. Endovascular repair may be effective in the short-term. Further studies are required to evaluate the long-term efficacy of endovascular repair.

  16. Popliteal artery entrapment syndrome.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2010-01-01

    Popliteal artery entrapment syndrome is a rare abnormality of the anatomical relationship between the popliteal artery and adjacent muscles or fibrous bands in the popliteal fossa. The following is a case report of a 19 year old female, in whom popliteal artery entrapment syndrome was diagnosed, and successfully treated surgically. A review of literature is also presented and provides details on how PAES is classified, diagnosed both clinically and radiologically, and treated surgically.

  17. Classification of distal fingertip amputation based on the arterial system for replantation.

    Science.gov (United States)

    Park, Hyun Chul; Bahar-Moni, Ahmed Suparno; Cho, Sang Hyun; Kim, Sang Soo; Park, Hyun Sik; Ahn, Sang Cheon

    2013-06-01

    During replantation of distal fingertip amputation, identification of the artery is the most important but time consuming procedure. Depending on the damaged arterial structure, we classified distal fingertip amputations into 4 zones, on the basis of three dimensional concept. Zone 1 injury was defined as damage to the proximal central pulp artery; zone 2 injury, damage to the branch of the central pulp artery; zone 3 injury, damage to the distal central pulp artery; and zone 4 injury, no injury to the central pulp artery, injury only to the lateral pulp artery. From April 2010 to June 2011, 27 patients were evaluated. Successful replantation was observed in 21 patients. Skin necrosis occurred in six patients. For distal fingertip amputation classification based on the damaged arterial system is an easy method to find out the appropriate artery which should be anastomosed during replantation.

  18. Chemoembolization through intercostal arteries in hepatocellular carcinoma: Report of a case of transient spinal cord injury

    International Nuclear Information System (INIS)

    Moon, Tae Yong; Hwang, In Tae; Kim, Byung Soo; Ko, Hyun Yoon; Yang, Ung Suk; Kim, Hak Jin

    1994-01-01

    Liver has a dual blood supply from portal vein and hepatic artery. Hepatocellular carcinoma receive their blood supply almost exclusively from hepatic artery. Thus, the concept of treating hepatocellular carcinoma by chemoembolization through these arteries is very effective . However, there may be several collateral or parasitic vessels feeding them in case of huge tumor or previous chemoembolization. We experienced a case of huge tumor involving right upper posterior portion of liver fed by 9th, 10th, 11th right posterior intercostal arteries and an anomalous hepatic artery. We tried chemoembolization with Adriamycin-Lipiodol suspension and Gelfoam material through the right posterior intercostal arteries to treat the lesion. After the procedure, the patient(55 years old female) became paraplegic with voiding and defecation difficulty which could be due to spinal cord infarction by anterior spinal arterial occlusion caused by embolic material through the artery of Adamkiewicz from a posterior intercostal artery. She recovered completely after 20 days of treatment

  19. Normal variation of hepatic artery

    International Nuclear Information System (INIS)

    Kim, Inn; Nam, Myung Hyun; Rhim, Hyun Chul; Koh, Byung Hee; Seo, Heung Suk; Kim, Soon Yong

    1987-01-01

    This study was an analyses of blood supply of the liver in 125 patients who received hepatic arteriography and abdominal aortography from Jan. 1984 to Dec. 1986 at the Department of Radiology of Hanyang University Hospital. A. Variations in extrahepatic arteries: 1. The normal extrahepatic artery pattern occurred in 106 of 125 cases (84.8%) ; Right hepatic and left hepatic arteries arising from the hepatic artery proper and hepatic artery proper arising from the common hepatic artery. 2. The most common type of variation of extrahepatic artery was replaced right hepatic artery from superior mesenteric artery: 6 of 125 cases (4.8%). B. Variations in intrahepatic arteries: 1. The normal intrahepatic artery pattern occurred in 83 of 125 cases (66.4%). Right hepatic and left hepatic arteries arising from the hepatic artery proper and middle hepatic artery arising from lower portion of the umbilical point of left hepatic artery. 2. The most common variation of intrahepatic arteries was middle hepatic artery. 3. Among the variation of middle hepatic artery; Right, middle and left hepatic arteries arising from the same location at the hepatic artery proper was the most common type; 17 of 125 cases (13.6%)

  20. Renal Branch Artery Stenosis

    DEFF Research Database (Denmark)

    Andersson, Zarah; Thisted, Ebbe; Andersen, Ulrik Bjørn

    2017-01-01

    Renovascular hypertension is a common cause of pediatric hypertension. In the fraction of cases that are unrelated to syndromes such as neurofibromatosis, patients with a solitary stenosis on a branch of the renal artery are common and can be diagnostically challenging. Imaging techniques...... that perform well in the diagnosis of main renal artery stenosis may fall short when it comes to branch artery stenosis. We report 2 cases that illustrate these difficulties and show that a branch artery stenosis may be overlooked even by the gold standard method, renal angiography....

  1. Imaging the vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Davies, John R.; Weissberg, Peter L. [Addenbrooke' s Hospital and University of Cambridge, Division of Cardiovascular Medicine, Cambridge (United Kingdom); Gillard, Jonathan H. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Addenbrooke' s Hospitald, University Department of Radiology, Cambridge (United Kingdom)

    2005-07-01

    Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)

  2. Imaging the vertebral artery

    International Nuclear Information System (INIS)

    Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M.; Davies, John R.; Weissberg, Peter L.; Gillard, Jonathan H.

    2005-01-01

    Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)

  3. Congenital coronary artery fistula

    International Nuclear Information System (INIS)

    Oh, Yeon Hee; Kim, Hong; Zeon, Seoc Kil; Suh, Soo Jhi

    1986-01-01

    Congenital coronary artery fistula (CCAF) is communication of a coronary artery or its main branch with one of the atria or ventricles, the coronary sinus, the superior vena cava, or the pulmonary artery. In Korean peoples, only 4 cases of the CCAF were reported as rare as worldwide and authors want to report another case of CCAF, confirmed by operation. 10-year-old girl shows a fistula between sinus node artery of the right coronary artery and right atrium on root aortogram with left-to-right shunt and Qp/Qs=1.58, in which simple ligation of the sinus node artery from right coronary artery was performed. All of the 5 Korean CCAF (4 were previously reported and 1 of authors) were originated from right coronary artery, and of which 4 were opening into right ventricle and 1 of authors were into right atrium. Associated cardiac anomaly was noted in only 1 case as single coronary artery. Ages were from 9 months of age to 10 years old and no adult left case were found. 3 were female and 2 were male patients.

  4. High current vacuum closing switch

    International Nuclear Information System (INIS)

    Dolgachev, G.I.; Maslennikov, D.D.; Romanov, A.S.; Ushakov, A.G.

    2005-01-01

    The paper proposes a powerful pulsed closing vacuum switch for high current commutation consisting of series of the vacuum diodes with near 1 mm gaps having closing time determined by the gaps shortening with the near-electrode plasmas [ru

  5. Wide Bandgap Extrinsic Photoconductive Switches

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, James S. [State Univ. of New York (SUNY), Plattsburgh, NY (United States); Univ. of California, Davis, CA (United States)

    2012-01-20

    Photoconductive semiconductor switches (PCSS) have been investigated since the late 1970s. Some devices have been developed that withstand tens of kilovolts and others that switch hundreds of amperes. However, no single device has been developed that can reliably withstand both high voltage and switch high current. Yet, photoconductive switches still hold the promise of reliable high voltage and high current operation with subnanosecond risetimes. Particularly since good quality, bulk, single crystal, wide bandgap semiconductor materials have recently become available. In this chapter we will review the basic operation of PCSS devices, status of PCSS devices and properties of the wide bandgap semiconductors 4H-SiC, 6H-SiC and 2H-GaN.

  6. Switching of chirality by light

    NARCIS (Netherlands)

    Feringa, B.L.; Schoevaars, A.M; Jager, W.F.; de Lange, B.; Huck, N.P.M.

    1996-01-01

    Optically active photoresponsive molecules are described by which control of chirality is achieved by light. These chiroptical molecular switches are based on inherently dissymmetric overcrowded alkenes and the synthesis, resolution and dynamic stereochemical properties are discussed. Introduction

  7. Aurora oil switch upgrade program

    International Nuclear Information System (INIS)

    Warren, T.

    1989-03-01

    This report describes the short pulse synchronization requirements, the original Aurora trigger scheme, and the PI/SNLA approach to improving the synchronization. It also describes the oil switching design study undertaken as the first phase of the program. A discussion of oil-switch closure analysis and the conceptual design motivated by this analysis are presented. This paper also describes the oil-switch trigger pulser tests required to validate the concept. This includes the design of the testing facility, a description of the test goals, and a discussion of the results. This paper finally describes oil-switch trigger pulser testing on one of the four Aurora Blumlein modules, which includes the hardware design and operation, the testing goals, hardware installation, and test results. 9 refs., 26 figs

  8. Solid state bistable power switch

    Science.gov (United States)

    Bartko, J.; Shulman, H.

    1970-01-01

    Tin and copper provide high current and switching time capabilities for high-current resettable fuses. They show the best performance for trip current and degree of reliability, and have low coefficients of thermal expansion.

  9. Intrinsic nanofilamentation in resistive switching

    KAUST Repository

    Wu, Xing; Cha, Dong Kyu; Bosman, Michel; Raghavan, Nagarajan; Migas, Dmitri B.; Borisenko, Victor E.; Zhang, Xixiang; Li, Kun; Pey, Kin-Leong

    2013-01-01

    -chip circuitry and non-volatile memory storage. Here, we provide insight into the mechanisms that govern highly reproducible controlled resistive switching via a nanofilament by using an asymmetric metal-insulator-semiconductor structure. In-situ transmission

  10. Electron collisions in gas switches

    International Nuclear Information System (INIS)

    Christophorou, L.G.

    1989-01-01

    Many technologies rely on the conduction/insulation properties of gaseous matter for their successful operation. Many others (e.g., pulsed power technologies) rely on the rapid change (switching or modulation) of the properties of gaseous matter from an insulator to a conductor and vice versa. Studies of electron collision processes in gases aided the development of pulsed power gas switches, and in this paper we shall briefly illustrate the kind of knowledge on electron collision processes which is needed to optimize the performance of such switching devices. To this end, we shall refer to three types of gas switches: spark gap closing, self-sustained diffuse discharge closing, and externally-sustained diffuse discharge opening. 24 refs., 15 figs., 2 tabs

  11. A Piezoelectric Cryogenic Heat Switch

    Science.gov (United States)

    Jahromi, Amir E.; Sullivan, Dan F.

    2014-01-01

    We have measured the thermal conductance of a mechanical heat switch actuated by a piezoelectric positioner, the PZHS (PieZo electric Heat Switch), at cryogenic temperatures. The thermal conductance of the PZHS was measured between 4 K and 10 K, and on/off conductance ratios greater than 100 were achieved when the positioner applied its maximum force of 8 N. We discuss the advantages of using this system in cryogenic applications, and estimate the ultimate performance of an optimized PZHS.

  12. High PRF high current switch

    Science.gov (United States)

    Moran, Stuart L.; Hutcherson, R. Kenneth

    1990-03-27

    A triggerable, high voltage, high current, spark gap switch for use in pu power systems. The device comprises a pair of electrodes in a high pressure hydrogen environment that is triggered by introducing an arc between one electrode and a trigger pin. Unusually high repetition rates may be obtained by undervolting the switch, i.e., operating the trigger at voltages much below the self-breakdown voltage of the device.

  13. First clinical experience with Celt ACD(®) : a femoral arterial puncture closure device.

    LENUS (Irish Health Repository)

    Jan, Aftab

    2013-08-01

    This prospective nonrandomized study compared the safety and efficacy of a novel arterial closure device (ACD) in common femoral artery procedures to that of the FDA submitted historical manual pressure control group, who underwent either a diagnostic angiogram (DA) or a percutaneous coronary intervention (PCI) procedure.

  14. Chromatic interocular-switch rivalry.

    Science.gov (United States)

    Christiansen, Jens H; D'Antona, Anthony D; Shevell, Steven K

    2017-05-01

    Interocular-switch rivalry (also known as stimulus rivalry) is a kind of binocular rivalry in which two rivalrous images are swapped between the eyes several times a second. The result is stable periods of one image and then the other, with stable intervals that span many eye swaps (Logothetis, Leopold, & Sheinberg, 1996). Previous work used this close kin of binocular rivalry with rivalrous forms. Experiments here test whether chromatic interocular-switch rivalry, in which the swapped stimuli differ in only chromaticity, results in slow alternation between two colors. Swapping equiluminant rivalrous chromaticities at 3.75 Hz resulted in slow perceptual color alternation, with one or the other color often continuously visible for two seconds or longer (during which there were 15+ eye swaps). A well-known theory for sustained percepts from interocular-switch rivalry with form is inhibitory competition between binocular neurons driven by monocular neurons with matched orientation tuning in each eye; such binocular neurons would produce a stable response when a given orientation is swapped between the eyes. A similar model can account for the percepts here from chromatic interocular-switch rivalry and is underpinned by the neurophysiological finding that color-preferring binocular neurons are driven by monocular neurons from each eye with well-matched chromatic selectivity (Peirce, Solomon, Forte, & Lennie, 2008). In contrast to chromatic interocular-switch rivalry, luminance interocular-switch rivalry with swapped stimuli that differ in only luminance did not result in slowly alternating percepts of different brightnesses.

  15. Nonvolatile Resistive Switching Memory Utilizing Cobalt Embedded in Gelatin

    Directory of Open Access Journals (Sweden)

    Cheng-Jung Lee

    2017-12-01

    Full Text Available This study investigates the preparation and electrical properties of Al/cobalt-embedded gelatin (CoG/ indium tin oxide (ITO resistive switching memories. Co. elements can be uniformly distributed in gelatin without a conventional dispersion procedure, as confirmed through energy dispersive X-ray analyzer and X-ray photoelectron spectroscopy observations. With an appropriate Co. concentration, Co. ions can assist the formation of an interfacial AlOx layer and improve the memory properties. High ON/OFF ratio, good retention capability, and good endurance switching cycles are demonstrated with 1 M Co. concentration, in contrast to 0.5 M and 2 M memory devices. This result can be attributed to the suitable thickness of the interfacial AlOx layer, which acts as an oxygen reservoir and stores and releases oxygen during switching. The Co. element in a solution-processed gelatin matrix has high potential for bio-electronic applications.

  16. HAL-RAR (Doppler guided haemorrhoid artery ligation with recto-anal repair) is a safe and effective procedure for haemorrhoids. Results of a prospective study after two-years follow-up.

    Science.gov (United States)

    Hoyuela, Carlos; Carvajal, Fernando; Juvany, Montserrat; Troyano, Daniel; Trias, Miquel; Martrat, Antoni; Ardid, Jordi; Obiols, Joan

    2016-04-01

    To analyse prospectively results of HAL-RAR technique by evaluating pain, perioperative complications and clinical outcome after two years followup. A prospective study design including 30 consecutive patients with haemorrhoids grade III-IV treated from June 2012. After discharge, patients received a specific questionnaire to record postoperative pain, delayed complications, evolution/disappearance of the symptoms that led to the surgical intervention (bleeding, prolapse, itching, pain and soiling). A visual analog scale (VAS) was used to measure pain. Outpatient follow-up was carried out at 7 days, and 1, 6 and 12 months and annually thereafter. Pre, intra and postoperative data (including physical examination) had been recorded prospectively. The median operating time (range) was 40 (26-60) minutes. Average hospital stay (range) was 11 (3-25) hours. No postoperative complications were observed in 29 cases (96.6%). Median follow-up was 26 (12-36) months. All the patients attended the follow-up. Mean postoperative pain was VAS = 1.7 on the seventh day and it was practically non-existent (VAS = 0.7) 1 month after the procedure. 87.5% of patients confirmed complete relief of symptoms after 30 days and 93% of patients feel free of symptoms 6 months after the procedure. No patient has experienced late complications as dyschezia, urgency, soiling or faecal incontinence. After 24 months follow-up, recurrence of bleeding and prolapse was observed in only 1 patient; 93% of patients have considered results of HAL-RAR as very good or excellent. HAL-RAR is safe and almost painless technique and it has very good results in the control of haemorrhoidal symptoms. This procedure should be considered as an effective first treatment option for haemorrhoids. Copyright © 2016 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  17. CONTROL OF BOUNCING IN RF MEMS SWITCHES USING DOUBLE ELECTRODE

    KAUST Repository

    Abdul Rahim, Farhan

    2014-01-01

    MEMS based mechanical switches are seen to be the likely replacements for CMOS based switches due to the several advantages that these mechanical switches have over CMOS switches. Mechanical switches can be used in systems under extreme conditions

  18. Increased bleeding risk during percutaneous coronary interventions by arterial hypertension.

    Science.gov (United States)

    Ndrepepa, Gjin; Groha, Philipp; Lahmann, Anna L; Lohaus, Raphaela; Cassese, Salvatore; Schulz-Schüpke, Stefanie; Kufner, Sebastian; Mayer, Katharina; Bernlochner, Isabell; Byrne, Robert A; Fusaro, Massimiliano; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan

    2016-08-01

    We aimed to assess the association between arterial hypertension and bleeding in patients undergoing percutaneous coronary intervention (PCI). The impact of arterial hypertension on bleeding risk of patients with coronary artery disease undergoing PCI is unknown. This study included 14,180 patients who underwent PCI. Bleeding was defined using the Bleeding Academic Research Consortium (BARC) criteria. Arterial hypertension was defined as treatment with antihypertensive drugs or a systolic blood pressure >140 mm Hg and/or diastolic blood pressure value >90 mm Hg documented on at least 2 occasions. The primary outcome was bleeding rate within 30 days of PCI. Overall, 11,066 patients (78.0%) had arterial hypertension. Bleeding events occurred in 1,232 patients with arterial hypertension and 278 patients without arterial hypertension (11.1% vs 8.9%; odds ratio [OR] = 1.28, 95% confidence interval [CI] 1.11-1.46, P arterial hypertension and 175 patients without arterial hypertension (6.6% vs 5.6%: OR = 1.19 [1.01-1.41], P = 0.049). Non-access-site bleeding occurred in 502 patients with and 103 patients without arterial hypertension (4.5% vs 3.3%; OR = 1.39 [1.12-1.72], P = 0.003). After adjustment, arterial hypertension was significantly associated with any bleeding (adjusted OR = 1.41 [1.19-1.67], P arterial hypertension increased the risk of non-access-site bleeding (P = 0.002), whereas systolic blood pressure at the time of PCI increased the risk of access site bleeding (P = 0.018). Arterial hypertension is associated with increased risk of bleeding during PCI procedures. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  19. Pulmonary artery aneurysm

    African Journals Online (AJOL)

    Enrique

    Introduction. Pulmonary artery aneurysms are a rare finding in general radiological practice. The possible causes are myriad and diverse in pathophysiolo- gy. Patients with post-stenotic dilata- tion of the main pulmonary artery usually present fairly late with insidi- ous cardiorespiratory symptoms. Diagnosis requires ...

  20. BILATERAL DUPLICATION OF RENAL ARTERIES

    OpenAIRE

    Prajkta A Thete; Mehera Bhoir; M.V.Ambiye

    2014-01-01

    Routine dissection of a male cadaver revealed the presence of bilateral double renal arteries. On the right side the accessory renal artery originated from the abdominal aorta just above the main renal artery. On the left side the accessory renal artery originated from the abdominal aorta about 1 cm above the main renal artery. Knowledge of the variations of renal vascular anatomy has importance in exploration and treatment of renal trauma, renal transplantation, renal artery embolization, su...

  1. Switched capacitor DC-DC converter with switch conductance modulation and Pesudo-fixed frequency control

    DEFF Research Database (Denmark)

    Larsen, Dennis Øland; Vinter, Martin; Jørgensen, Ivan Harald Holger

    A switched capacitor dc-dc converter with frequency-planned control is presented. By splitting the output stage switches in eight segments the output voltage can be regulated with a combination of switching frequency and switch conductance. This allows for switching at predetermined frequencies, 31...

  2. A Switch Is Not a Switch: Syntactically-Driven Bilingual Language Control

    Science.gov (United States)

    Gollan, Tamar H.; Goldrick, Matthew

    2018-01-01

    The current study investigated the possibility that language switches could be relatively automatically triggered by context. "Single-word switches," in which bilinguals switched languages on a single word in midsentence and then immediately switched back, were contrasted with more complete "whole-language switches," in which…

  3. Principles of broadband switching and networking

    CERN Document Server

    Liew, Soung C

    2010-01-01

    An authoritative introduction to the roles of switching and transmission in broadband integrated services networks Principles of Broadband Switching and Networking explains the design and analysis of switch architectures suitable for broadband integrated services networks, emphasizing packet-switched interconnection networks with distributed routing algorithms. The text examines the mathematical properties of these networks, rather than specific implementation technologies. Although the pedagogical explanations in this book are in the context of switches, many of the fundamenta

  4. Bilateral triple renal arteries

    International Nuclear Information System (INIS)

    Pestemalci, Turan; Yildiz, Yusuf Zeki; Yildirim, Mehmet; Mavi, Ayfer; Gumusburun, Erdem

    2009-01-01

    Knowledge of the variations of the renal artery has grown in importance with increasing numbers of renal transplants, vascular reconstructions and various surgical and radio logic techniques being performed in recent years. We report the presence of bilateral triple renal arteries, discovered on routine dissection of a male cadaver. On the right side, one additional renal artery originated from the abdominal aorta (distributed to superior pole of the kidney) and one other originated from the right common iliac artery (distributed to lower pole of the kidney). On the left side, both additional renal arteries originated from the abdominal aorta. Our observation has been compared with variations described in the literature and their clinical importance has been emphasized. (author)

  5. Occlusion of Heubner's artery

    International Nuclear Information System (INIS)

    Sato, Manabu; Kidooka, Minoru

    1982-01-01

    A case of occlusion of the left Heubner's artery in a right-handed, 51-year-old man is reported. Cardinal clinical features were transient right hemiparesis and mental disturbance, especially intellectual defect. Low density areas were found at CT in the globus pallidus, putamen, anterior limb of the internal capsule and a part of the caudate nucleus. It is well known that the occlusion of the Heubner's artery causes transient motor paresis of upper extremity on the contralaterl side. However, in the case where the Heubner's artery is remarkably well developed when compared with the medial striate arteries as was the case in this patient, it should be noted that the occlusion of the Heubner's artery may well causes grave mental disturbance, in addition. (author)

  6. Switching dynamics of TaOx-based threshold switching devices

    Science.gov (United States)

    Goodwill, Jonathan M.; Gala, Darshil K.; Bain, James A.; Skowronski, Marek

    2018-03-01

    Bi-stable volatile switching devices are being used as access devices in solid-state memory arrays and as the active part of compact oscillators. Such structures exhibit two stable states of resistance and switch between them at a critical value of voltage or current. A typical resistance transient under a constant amplitude voltage pulse starts with a slow decrease followed by a rapid drop and leveling off at a low steady state value. This behavior prompted the interpretation of initial delay and fast transition as due to two different processes. Here, we show that the entire transient including incubation time, transition time, and the final resistance values in TaOx-based switching can be explained by one process, namely, Joule heating with the rapid transition due to the thermal runaway. The time, which is required for the device in the conducting state to relax back to the stable high resistance one, is also consistent with the proposed mechanism.

  7. The arterial blood supply of the temporomandibular joint: an anatomical study and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Cuccia, Antonino Marco; Caradonna, Carola; Caradonna, Domenico [Dept. of Surgical and Oncological Disciplines, University of Palermo, Palermo (Italy); Anastasi, Giuseppe; Milardi, Demetrio; Favaloro, Angelo; Caradonna, Luigi; Cutroneo, Giuseppina [Biomorphology and Biotechnologies, University of Messina, Messina (Italy); De Pietro, Anita; Angileri, Tommaso Maurizio [Villa Santa Teresa, Diagnostica per Immagini, Palermo (Italy)

    2013-03-15

    The aim of this study was to analyze three-dimensional images of the arterial supply to the temporomandibular joint. Ten patients (five men and five women, mean age 36 years) without signs or symptoms of temporomandibular disorders, who underwent contrast-enhanced computed tomographic (CT) scanning with intravenous contrast, were studied. The direct volume rendering technique of CT images was used, and a data set of images to visualize the vasculature of the human temporomandibular joint in three dimensions was created. After elaboration of the data through post-processing, the arterial supply of the temporomandibular joint was studied. The analysis revealed the superficial temporal artery, the anterior tympanic artery, the deep temporal artery, the auricular posterior artery, the transverse facial artery, the middle meningeal artery, and the maxillary artery with their branches as the main arterial sources for the lateral and medial temporomandibular joint. The direct volume rendering technique was found to be successful in the assessment of the arterial supply to the temporomandibular joint. The superficial temporal artery and maxillary artery ran along the lateral and medial sides of the condylar neck, suggesting that these arteries are at increased risk during soft-tissue procedures such as an elective arthroplasty of the temporomandibular joint.

  8. The clinical significance of anomalous origination of right gastric artery in interventional treatment for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Lin Zhidong; Wen Chongpei; Fu Kong; Wang Banghao

    2010-01-01

    Objective: To discuss the clinical significance of anomalous origination of right gastric artery in interventional treatment for hepatocellular carcinoma (HCC). Methods: The dynamic enhanced CT scanning of the liver with a 64-slice spiral CT unit was performed in 72 HCC patients. In arterial phase, maximum intensity projection (MIP) and volume reconstruction technique (VRT) were used to observe the origin of the right gastric artery and its relationship with the hepatic artery. The findings were compared with the angiographic results. Results: Of the total 72 cases, the anomalous origin of the right gastric artery was found in 43 (59.8%). The anomalous origins of the right gastric artery included proper hepatic artery (n=19), left hepatic artery (n=17), gastroduodenal artery (n=4), right hepatic artery (n=2) and common hepatic artery (n=1). The results obtained from three-dimensional reconstruction were in good accordance with angiographic findings. Conclusion: The anomalously originated right gastric artery most commonly originates from the left hepatic artery. Three-dimensional reconstruction obtained from the 64-slice spiral CT scans can provide the clear and reliable images of the right gastric artery, which is very helpful for the interventional procedure. (authors)

  9. The establishment of bilateral external iliac artery stenosis model in experimental canines and its angiographic evaluation

    International Nuclear Information System (INIS)

    Xia Yonghui; Li Weixiao; Bi Yonghua; Xu Ke

    2011-01-01

    Objective: To establish an experimental canine model of bilateral external iliac artery stenosis by surgical method with absorbable suture. Methods: Under general anesthesia bilateral external iliac arteries were partly obstructed (about 50%) with absorbable suture in ten dogs. Three months later angiography was performed to evaluate the arterial stricture degree. Results: Bilateral external iliac artery stenosis model was successfully established in eight dogs and the other two dogs died within two weeks after the procedure. Angiography performed three months after the procedure showed that the stricture degree of arterial lumen was (60.6±12.5)%. Conclusion: Satisfactory experimental canine model of bilateral external iliac artery stenosis can be established by surgical method with absorbable suture. This method can be used for reference when peripheral artery stenosis model is to be prepared in larger animals. (authors)

  10. [Surgical angioplasty of the left main coronary artery].

    Science.gov (United States)

    Vranes, Mile; Velinović, Milos; Kocica, Mladen; Mikić, Aleksandar; Velimirović, Dusan; Djukić, Petar

    2010-01-01

    The conventional treatment for isolated stenosis of the left main coronary artery is bypass surgery (myocardial revascularization). However, the process of atherosclerosis is not arrested by myocardial revascularization and it will lead to the occlusion of the left main coronary artery. Revascularization will establish retrograde perfusion for 50-70% of the myocardium of the left ventricle. Direct surgical angioplasty of the left main coronary artery enables normal physiological perfusion of the whole myocardium and better myocardial function. The aim of our study is to point out a new surgical approach of treating left main coronary artery stenosis. Between October 2002 and October 2003, direct surgical angioplasty of the main left coronary artery was performed on three patients with isolated stenosis of the left main coronary artery using the anterior approach and the pericardium as a patch. The procedure was performed under total endotracheal anaesthesia and standard cardiopulmonary circulation, moderate hypothermia, anterograde St. Tomas cardioplegia and local cooling. Patients were followed clinically, echocardiographically and by load-tests. All three patients were without complications. In postoperative follow-up (54-68 months) neither angina pectoris nor electrocardiographically registered ischaemic changes were found. Load-tests performed every six months on all three patients were negative. Surgical angioplasty of isolated stenosis of the left main coronary artery is a preferred method for treating this type of coronary disease. Contraindications for this type of treatment are stenosis of the left main coronary artery with bifurcation and advanced calcification of the left main coronary artery.

  11. IGBT: a solid state switch

    International Nuclear Information System (INIS)

    Chatroux, D.; Maury, J.; Hennevin, B.

    1993-01-01

    A Copper Vapour Laser Power Supply has been designed using a solid state switch consisting in eighteen Isolated Gate Bipolar Transistors (IGBT), -1200 volts, 400 Amps, each-in parallel. This paper presents the Isolated Gate Bipolar Transistor (IGBTs) replaced in the Power Electronic components evolution, and describes the IGBT conduction mechanism, presents the parallel association of IGBTs, and studies the application of these components to a Copper Vapour Laser Power Supply. The storage capacitor voltage is 820 volts, the peak current of the solid state switch is 17.000 Amps. The switch is connected on the primary of a step-up transformer, followed by a magnetic modulator. The reset of the magnetic modulator is provided by part of the laser reflected energy with a patented circuit. The charging circuit is a resonant circuit with a charge controlled by an IGBT switch. When the switch is open, the inductance energy is free-wheeled by an additional winding and does not extend the charging phase of the storage capacitor. The design allows the storage capacitor voltage to be very well regulated. This circuit is also patented. The electric pulse in the laser has 30.000 Volt peak voltage, 2000 Amp peak current, and is 200 nanoseconds long, for a 200 Watt optical power Copper Vapour Laser

  12. Clinical study of color Doppler sonography in Graves' disease blood flow changes after thyroid arteries embolization

    International Nuclear Information System (INIS)

    Zhuang Wenquan; Li Weiduo; Yang Jianyong; Chen Wei; Huang Yonghui; Guo Wenbo; Li Jiaping

    2003-01-01

    Objective: To study the color doppler image characteristics of thyroid arteries pre- and post-interventional procedure and to assess the clinical efficacy in Gnaves' disease. Methods: 11 from 31 patients diagnosed as Graves' disease undertaken thyroid arteries embolization, were analyzed. Color Doppler sonography was applied to monitor the pre-and post- procedure thyroid size and diameters of thyroid arteries. Power Doppler was used to detect the Vmax, Vmin, RI and blood flow. Results: After thyroid arteries embolization, the size and vascularity of thyroids were reduced. The thyroid arteries showed shrinkage and stoppage blood flow at the embolized site. The changes of RI, blood parameters of Vmax, Vmin and diameters of the thyroid arteries pre- and post-procedure turned out to be statistically significant for clinical restriction. Conclusion: The color Doppler sonography plays an important role for preoperative diagnosis and predicting the prognosis

  13. Endovascular Management of Central Retinal Arterial Occlusion.

    Science.gov (United States)

    Agarwal, Nitin; Gala, Nihar B; Baumrind, Benjamin; Hansberry, David R; Thabet, Ahmad M; Gandhi, Chirag D; Prestigiacomo, Charles J

    2016-11-01

    Central retinal artery occlusion (CRAO) is an ophthalmologic emergency due to the sudden cessation of circulation to the inner retinal layer. Without immediate treatment, permanent blindness may ensue. Several treatment options exist, ranging from noninvasive medical management to thrombolysis. Nonetheless, ongoing debate exists regarding the best therapeutic strategy. The authors present the case of a 78-year-old woman with a medical history of hypercholesterolemia and rheumatoid arthritis who experienced complete loss of vision in her left eye. Following ophthalmologic evaluation demonstrating left CRAO, anterior chamber paracentesis was performed. Endovascular intervention was performed via local intra-arterial fibrinolysis with alteplase. Her vision returned to 20/20 following the procedure. In general, conventional therapies have not significantly improved patient outcomes. Several management options exist for CRAO. In general, conservative measures have not been reported to yield better patient outcomes as compared to the natural history of this medical emergency. Endovascular approaches are another option as observed with this case reported. In cases of CRAO, therapeutic strategies such as intra-arterial fibrinolysis utilize a local infusion of reactive tissue plasminogen activator directly at the site of occlusion via catheterization of the ophthalmic artery. Although several case series do show promising results after treating CRAO with intra-arterial fibrinolysis, further studies are required given the reports of complications.

  14. Fiber Bragg grating based arterial localization device

    Science.gov (United States)

    Ho, Siu Chun Michael; Li, Weijie; Razavi, Mehdi; Song, Gangbing

    2017-06-01

    A critical first step to many surgical procedures is locating and gaining access to a patients vascular system. Vascular access allows the deployment of other surgical instruments and also the monitoring of many physiological parameters. Current methods to locate blood vessels are predominantly based on the landmark technique coupled with ultrasound, fluoroscopy, or Doppler. However, even with experience and technological assistance, locating the required blood vessel is not always an easy task, especially with patients that present atypical anatomy or suffer from conditions such as weak pulsation or obesity that make vascular localization difficult. With recent advances in fiber optic sensors, there is an opportunity to develop a new tool that can make vascular localization safer and easier. In this work, the authors present a new fiber Bragg grating (FBG) based vascular access device that specializes in arterial localization. The device estimates the location towards a local artery based on the bending of a needle inserted near the tissue surrounding the artery. Experimental results obtained from an artificial circulatory loop and a mock artery show the device works best for lower angles of needle insertion and can provide an approximately 40° range of estimation towards the location of a pulsating source (e.g. an artery).

  15. Comparison of the vasodilator responses of isolated human and rat middle meningeal arteries to migraine related compounds

    DEFF Research Database (Denmark)

    Grände, Gustaf; Labruijere, Sieneke; Haanes, Kristian Agmund

    2014-01-01

    , telcagepant) were applied to the isolated arteries, and both induced a significant decrease of the effect of exogenously administrated CGRP. In experiments on rat middle meningeal arteries, pre-contracted with PGF2α, similar tendencies were seen. When the pre-contraction was switched to K+ in a separate...... series of experiments, CGRP and sildenafil significantly relaxed the arteries. CONCLUSIONS: Still no definite answer can be given as to why pain is experienced during an attack of migraine. No clear correlation was found between the efficacy of a substance as a meningeal artery vasodilator in human...

  16. Renal artery stenosis

    International Nuclear Information System (INIS)

    Desberg, A.; Paushter, D.M.; Lammert, G.K.; Hale, J.; Troy, R.; Novic, A.; Nally, J. Jr.

    1989-01-01

    Renal artery disease is a potentially correctable cause of hypertension. Previous studies have suggested the utility of duplex sonography in accurately detecting and grading the severity of renal artery stenosis. The purpose of this paper is to evaluate color flow Doppler for this use. Forty-three kidneys were examined by color-flow Doppler and conventional duplex sampling in patients with suspected renovascular hypertension or those undergoing aortography for unrelated reasons. Doppler tracings were obtained from the renal arteries and aorta with calculation of the renal aortic ratio (RAR) and resistive index (RI). Results of Doppler sampling with color flow guidance were compared with aortograms in a blinded fashion

  17. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  18. Vertebrobasilar Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Schoen, Jessica

    2011-05-01

    Full Text Available The presentation of vertebrobasilar artery occlusion varies with the cause of occlusion and location of ischemia. This often results in delay in diagnosis. Areas of the brain supplied by the posterior circulation are difficult to visualize and usually require angiography or magnetic resonance imaging. Intravenous thrombolysis and local-intra arterial thrombolysis are the most common treatment approaches used. Recanalization of the occluded vessel significantly improves morbidity and mortality. Here we present a review of the literature and a case of a patient with altered mental status caused by vertebrobasilar artery occlusion. [West J Emerg Med. 2011;12(2:233-239.

  19. CMOS integrated switching power converters

    CERN Document Server

    Villar-Pique, Gerard

    2011-01-01

    This book describes the structured design and optimization of efficient, energy processing integrated circuits. The approach is multidisciplinary, covering the monolithic integration of IC design techniques, power electronics and control theory. In particular, this book enables readers to conceive, synthesize, design and implement integrated circuits with high-density high-efficiency on-chip switching power regulators. Topics covered encompass the structured design of the on-chip power supply, efficiency optimization, IC-compatible power inductors and capacitors, power MOSFET switches and effi

  20. All-fiber polarization switch

    Science.gov (United States)

    Knape, Harald; Margulis, Walter

    2007-03-01

    We report an all-fiber polarization switch made out of silica-based microstructured fiber suitable for Q-switching all-fiber lasers. Nanosecond high-voltage pulses are used to heat and expand an internal electrode to cause λ/2-polarization rotation in less than 10 ns for 1.5 μm light. The 10 cm long component has an experimentally measured optical insertion loss of 0.2 dB and a 0-10 kHz repetition frequency capacity and has been durability tested for more than 109 pulses.

  1. Transcatheter Arterial Embolization of Arterial Esophageal Bleeding with the Use of N-Butyl Cyanoacrylate

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Hoon; Kim, Hyo Cheol; Chung, Jin Wook; Jae, Hwan Jun; Park, Jae Hyung [Seoul National University Hospita, Seoul (Korea, Republic of)

    2009-08-15

    To evaluate the clinical efficacy and safety of a transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) for the treatment of arterial esophageal bleeding. Between August 2000 and April 2008, five patients diagnosed with arterial esophageal bleeding by conventional angiography, CT angiography or endoscopy, underwent a TAE with NBCA. We mixed NBCA with iodized oil at ratios of 1:1 to 1:4 to supply radiopacity and achieve a proper polymerization time. After embolization, we evaluated the angiographic and clinical success, recurrent bleeding, and procedure-related complications. The bleeding esophageal artery directly originated from the aorta in four patients and from the left inferior phrenic artery in one patient. Although four patients had an underlying coagulopathy at the time of the TAE, angiographic and clinical success was achieved in all five patients. In addition, no procedurerelated complications such as esophageal infarction were observed during this study. NBCA can be an effective and feasible embolic agent in patients with active arterial esophageal bleeding, even with pre-existing coagulopathy.

  2. Transcatheter Arterial Embolization of Arterial Esophageal Bleeding with the Use of N-Butyl Cyanoacrylate

    International Nuclear Information System (INIS)

    Park, Ji Hoon; Kim, Hyo Cheol; Chung, Jin Wook; Jae, Hwan Jun; Park, Jae Hyung

    2009-01-01

    To evaluate the clinical efficacy and safety of a transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) for the treatment of arterial esophageal bleeding. Between August 2000 and April 2008, five patients diagnosed with arterial esophageal bleeding by conventional angiography, CT angiography or endoscopy, underwent a TAE with NBCA. We mixed NBCA with iodized oil at ratios of 1:1 to 1:4 to supply radiopacity and achieve a proper polymerization time. After embolization, we evaluated the angiographic and clinical success, recurrent bleeding, and procedure-related complications. The bleeding esophageal artery directly originated from the aorta in four patients and from the left inferior phrenic artery in one patient. Although four patients had an underlying coagulopathy at the time of the TAE, angiographic and clinical success was achieved in all five patients. In addition, no procedurerelated complications such as esophageal infarction were observed during this study. NBCA can be an effective and feasible embolic agent in patients with active arterial esophageal bleeding, even with pre-existing coagulopathy

  3. Anomalous Medial Branch of Radial Artery: A Rare Variant

    Directory of Open Access Journals (Sweden)

    Surbhi Wadhwa

    2016-10-01

    Full Text Available Radial artery is an important consistent vessel of the upper limb. It is a useful vascular access site for coronary procedures and its reliable anatomy has resulted in an elevation of radial forearm flaps for reconstructive surgeries of head and neck. Technical failures, in both the procedures, are mainly due to anatomical variations, such as radial loops, ectopic radial arteries or tortuosity in the vessel. We present a rare and a unique anomalous medial branch of the radial artery spiraling around the flexor carpi radialis muscle in the forearm with a high rising superficial palmar branch of radial artery. Developmentally it probably is a remanent of the normal pattern of capillary vessel maintenance and regression. Such a case is of importance for reconstructive surgeons and coronary interventionists, especially in view of its unique medial and deep course.

  4. A level switch with a sound tube

    OpenAIRE

    赤池, 誠規

    2017-01-01

    Level switches are sensor with an electrical contact output at a specific liquid, powder or bulk level. Most of traditional level switches are not suitable for harsh environments. The level switch in this study connects a loudspeaker on top end of the sound tube. When liquid, powder or bulk closes bottom end of the sound tube, the level switch turns on. The level switch is suitable for harsh environments and easy to install. The aim of this study is to propose a level switch with a sound tube...

  5. [Endarterectomy of the coronary arteries].

    Science.gov (United States)

    Fischer, V; Simkovic, I; Holoman, M; Verchvodko, P; Janotík, P; Galbánek, J; Hulman, M; Kostelnicák, J; Jurco, R; Slezák, J

    1992-02-01

    The authors analyze 50 patients with endarterectomy of the coronary arteries during the periods of 1972-1974 and 1988-1990. The results of endarterectomy of the right and left coronary artery provide evidence of its justification in indicated cases whereby contrary to some departments the results of endarterectomy of the left coronary artery are comparable with endarterectomy of the right coronary artery.

  6. Endovascular Treatment of a Splenic Aneurysm Associated With Segmental Arterial Mediolysis

    Directory of Open Access Journals (Sweden)

    A. Khan

    Full Text Available : Introduction: Segmental arterial mediolysis is a rare disorder characterised by disintegration of the medial layer of an arterial wall usually affecting the intra-abdominal splanchnic vessels. Report: A case of 50 year old man who presented with sudden-onset left sided flank pain is reported. A computed tomography mesenteric angiogram showed haemorrhage and a stable left upper quadrant haematoma arising from 8 × 8 mm splenic artery aneurysm. Discussion: The patient underwent a successful endovascular coiling procedure to exclude the aneurysm and for complete resolution of his symptoms. Keywords: Segmental arterial mediolysis, Splanchnic vessels, Splenic artery aneurysm

  7. Stabilization of a percutaneously implanted port catheter system for hepatic artery chemotherapy infusion

    International Nuclear Information System (INIS)

    Shindoh, Noboru; Ozaki, Yutaka; Kyogoku, Shinsuke; Yamana, Daigo; Sumi, Yukiharu; Katayama, Hitoshi

    1999-01-01

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation.

  8. Anatomic variations of the cerebral arteries and their embryology: a pictorial review

    International Nuclear Information System (INIS)

    Okahara, Mika; Kiyosue, Hiro; Mori, Hiromu; Tanoue, Shuichi; Sainou, Michihumi; Nagatomi, Hirohumi

    2002-01-01

    In the embryonic period, several developmental anomalies of the cerebral arteries occur. The knowledge of these anatomic variations of the cerebral artery is important to avoid the unnecessary surgery and to undergo surgery or interventional radiology with safety. We reviewed 3000 MR angiographies and 700 cerebral angiographies of the previous 5 years to assess cerebral arterial system, and to illustrate the embryological development, imaging findings, occurrence, and clinical significance of the anatomic variation of the cerebral arteries. The normal development and variations of the cerebral arteries are depicted. Knowledge of the anatomic variations is important since it can influence surgical and interventional procedure. (orig.)

  9. Popliteal Arterial Aneurysms

    African Journals Online (AJOL)

    plication was acute arterial occlusion caused by thrombo- embolism. The reasons for ... Total. 43. 55. TABLE 11. CONCOMITANT DISEASE IN 38 PATIENTS .... Dacron prosthesis in 4. .... genous saphenous vein and the type of anastomosis.

  10. Coronary artery fistula

    Science.gov (United States)

    ... PA: Elsevier Saunders; 2015:chap 84. Friedman AH, Silverman NH. Congenital anomalies of the coronary arteries. In: ... provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the ...

  11. Endovascular treatment of nonvariceal acute arterial upper gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Andersen, Poul Erik; Duvnjak, Stevo

    2010-01-01

    Transcatheter arterial embolization as treatment of upper nonvariceal gastrointestinal bleeding is increasingly being used after failed primary endoscopic treatment. The results after embolization have become better and surgery still has a high mortality. Embolization is a safe and effective...... procedure, but its use is has been limited because of relatively high rates of rebleeding and high mortality, both of which are associated with gastrointestinal bleeding and non-gastrointestinal related mortality causes. Transcatheter arterial embolization is a valuable minimal invasive method...

  12. Aberrant hepatic artery

    International Nuclear Information System (INIS)

    Konstam, M.A.; Novelline, R.A.; Athanasoulis, C.A.

    1979-01-01

    In a patient undergoing selective hepatic arteriography for suspected liver trauma, a nonopacified area of the liver, initially thought to represent a hepatic hematoma, was later discovered to be due to the presence of an accessory right hepatic artery arising from the superior mesenteric artery. This case illustrates the need for a search for aberrant vasculature whenever a liver hematoma is suspected on the basis of a selective hepatic arteriogram. (orig.) [de

  13. Parent artery occlusion for ruptured “true” posterior communicating artery aneurysm

    Science.gov (United States)

    Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-01-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgical clipping over endovascular coil embolization. Endovascular treatment may be a good alternative to surgical trapping for true PCoA blister aneurysm. PMID:25953771

  14. Parent artery occlusion for ruptured “true” posterior communicating artery aneurysm

    OpenAIRE

    Mitsuhashi, Takashi; Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-01-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgi...

  15. Industry switching in developing countries

    DEFF Research Database (Denmark)

    Newman, Carol; Rand, John; Tarp, Finn

    2013-01-01

    Firm turnover (i.e., firm entry and exit) is a well-recognized source of sector-level productivity growth. In contrast, the role and importance of firms that switch activities from one sector to another is not well understood. Firm switchers are likely to be unique, differing from both newly esta...

  16. Nanoscale organic ferroelectric resistive switches

    NARCIS (Netherlands)

    Khikhlovskyi, V.; Wang, R.; Breemen, A.J.J.M. van; Gelinck, G.H.; Janssen, R.A.J.; Kemerink, M.

    2014-01-01

    Organic ferroelectric resistive switches function by grace of nanoscale phase separation in a blend of a semiconducting and a ferroelectric polymer that is sandwiched between metallic electrodes. In this work, various scanning probe techniques are combined with numerical modeling to unravel their

  17. Design of convergent switched systems

    NARCIS (Netherlands)

    Berg, van den R.A.; Pogromsky, A.Y.; Leonov, G.A.; Rooda, J.E.; Pettersen, K.Y.; Gravdahl, J.T.; Nijmeijer, H.

    2006-01-01

    In this paper we deal with the problem of rendering hybrid/nonlinear systems into convergent closed-loop systems by means of a feedback law or switching rules. We illustrate our approach to this problem by means of two examples: the anti-windup design for a marginally stable system with input

  18. Multiuser switched diversity scheduling schemes

    KAUST Repository

    Shaqfeh, Mohammad; Alnuweiri, Hussein M.; Alouini, Mohamed-Slim

    2012-01-01

    Multiuser switched-diversity scheduling schemes were recently proposed in order to overcome the heavy feedback requirements of conventional opportunistic scheduling schemes by applying a threshold-based, distributed, and ordered scheduling mechanism. The main idea behind these schemes is that slight reduction in the prospected multiuser diversity gains is an acceptable trade-off for great savings in terms of required channel-state-information feedback messages. In this work, we characterize the achievable rate region of multiuser switched diversity systems and compare it with the rate region of full feedback multiuser diversity systems. We propose also a novel proportional fair multiuser switched-based scheduling scheme and we demonstrate that it can be optimized using a practical and distributed method to obtain the feedback thresholds. We finally demonstrate by numerical examples that switched-diversity scheduling schemes operate within 0.3 bits/sec/Hz from the ultimate network capacity of full feedback systems in Rayleigh fading conditions. © 2012 IEEE.

  19. Stability of Randomly Switched Diffusions

    DEFF Research Database (Denmark)

    Schiøler, Henrik; Leth, John-Josef; Gholami, Mehdi

    2012-01-01

    This paper provides a sufficient criterion for ε-moment stability (boundedness) and ergodicity for a class of systems comprising a finite set of diffusions among which switching is governed by a continuous time Markov chain. Stability/instability properties for each separate subsystem are assumed...

  20. Industry Switching in Developing Countries

    DEFF Research Database (Denmark)

    Newman, Carol; Rand, John; Tarp, Finn

    Firm turnover (i.e. firm entry and exit) is a well-recognized source of sectorlevel productivity growth across developing and developed countries. In contrast, the role and importance of firms switching activities from one sector to another is little understood. Firm switchers are likely...

  1. Charge transport through molecular switches

    International Nuclear Information System (INIS)

    Jan van der Molen, Sense; Liljeroth, Peter

    2010-01-01

    We review the fascinating research on charge transport through switchable molecules. In the past decade, detailed investigations have been performed on a great variety of molecular switches, including mechanically interlocked switches (rotaxanes and catenanes), redox-active molecules and photochromic switches (e.g. azobenzenes and diarylethenes). To probe these molecules, both individually and in self-assembled monolayers (SAMs), a broad set of methods have been developed. These range from low temperature scanning tunneling microscopy (STM) via two-terminal break junctions to larger scale SAM-based devices. It is generally found that the electronic coupling between molecules and electrodes has a profound influence on the properties of such molecular junctions. For example, an intrinsically switchable molecule may lose its functionality after it is contacted. Vice versa, switchable two-terminal devices may be created using passive molecules ('extrinsic switching'). Developing a detailed understanding of the relation between coupling and switchability will be of key importance for both future research and technology. (topical review)

  2. Charge transport through molecular switches

    Energy Technology Data Exchange (ETDEWEB)

    Jan van der Molen, Sense [Kamerlingh Onnes Laboratorium, Leiden University, Niels Bohrweg 2, 2333 CA Leiden (Netherlands); Liljeroth, Peter, E-mail: molen@physics.leidenuniv.n [Condensed Matter and Interfaces, Debye Institute for Nanomaterials Science, University of Utrecht, PO Box 80000, 3508 TA Utrecht (Netherlands)

    2010-04-07

    We review the fascinating research on charge transport through switchable molecules. In the past decade, detailed investigations have been performed on a great variety of molecular switches, including mechanically interlocked switches (rotaxanes and catenanes), redox-active molecules and photochromic switches (e.g. azobenzenes and diarylethenes). To probe these molecules, both individually and in self-assembled monolayers (SAMs), a broad set of methods have been developed. These range from low temperature scanning tunneling microscopy (STM) via two-terminal break junctions to larger scale SAM-based devices. It is generally found that the electronic coupling between molecules and electrodes has a profound influence on the properties of such molecular junctions. For example, an intrinsically switchable molecule may lose its functionality after it is contacted. Vice versa, switchable two-terminal devices may be created using passive molecules ('extrinsic switching'). Developing a detailed understanding of the relation between coupling and switchability will be of key importance for both future research and technology. (topical review)

  3. Wide Bandgap Extrinsic Photoconductive Switches

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, James S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-07-03

    Semi-insulating Gallium Nitride, 4H and 6H Silicon Carbide are attractive materials for compact, high voltage, extrinsic, photoconductive switches due to their wide bandgap, high dark resistance, high critical electric field strength and high electron saturation velocity. These wide bandgap semiconductors are made semi-insulating by the addition of vanadium (4H and 6HSiC) and iron (2H-GaN) impurities that form deep acceptors. These deep acceptors trap electrons donated from shallow donor impurities. The electrons can be optically excited from these deep acceptor levels into the conduction band to transition the wide bandgap semiconductor materials from a semi-insulating to a conducting state. Extrinsic photoconductive switches with opposing electrodes have been constructed using vanadium compensated 6H-SiC and iron compensated 2H-GaN. These extrinsic photoconductive switches were tested at high voltage and high power to determine if they could be successfully used as the closing switch in compact medical accelerators.

  4. The Atlas load protection switch

    CERN Document Server

    Davis, H A; Dorr, G; Martínez, M; Gribble, R F; Nielsen, K E; Pierce, D; Parsons, W M

    1999-01-01

    Atlas is a high-energy pulsed-power facility under development to study materials properties and hydrodynamics experiments under extreme conditions. Atlas will implode heavy liner loads (m~45 gm) with a peak current of 27-32 MA delivered in 4 mu s, and is energized by 96, 240 kV Marx generators storing a total of 23 MJ. A key design requirement for Atlas is obtaining useful data for 95601130f all loads installed on the machine. Materials response calculations show current from a prefire can damage the load requiring expensive and time consuming replacement. Therefore, we have incorporated a set of fast-acting mechanical switches in the Atlas design to reduce the probability of a prefire damaging the load. These switches, referred to as the load protection switches, short the load through a very low inductance path during system charge. Once the capacitors have reached full charge, the switches open on a time scale short compared to the bank charge time, allowing current to flow to the load when the trigger pu...

  5. Intrinsic nanofilamentation in resistive switching

    KAUST Repository

    Wu, Xing

    2013-03-15

    Resistive switching materials are promising candidates for nonvolatile data storage and reconfiguration of electronic applications. Intensive studies have been carried out on sandwiched metal-insulator-metal structures to achieve high density on-chip circuitry and non-volatile memory storage. Here, we provide insight into the mechanisms that govern highly reproducible controlled resistive switching via a nanofilament by using an asymmetric metal-insulator-semiconductor structure. In-situ transmission electron microscopy is used to study in real-time the physical structure and analyze the chemical composition of the nanofilament dynamically during resistive switching. Electrical stressing using an external voltage was applied by a tungsten tip to the nanosized devices having hafnium oxide (HfO2) as the insulator layer. The formation and rupture of the nanofilaments result in up to three orders of magnitude change in the current flowing through the dielectric during the switching event. Oxygen vacancies and metal atoms from the anode constitute the chemistry of the nanofilament.

  6. Multiuser switched diversity scheduling schemes

    KAUST Repository

    Shaqfeh, Mohammad

    2012-09-01

    Multiuser switched-diversity scheduling schemes were recently proposed in order to overcome the heavy feedback requirements of conventional opportunistic scheduling schemes by applying a threshold-based, distributed, and ordered scheduling mechanism. The main idea behind these schemes is that slight reduction in the prospected multiuser diversity gains is an acceptable trade-off for great savings in terms of required channel-state-information feedback messages. In this work, we characterize the achievable rate region of multiuser switched diversity systems and compare it with the rate region of full feedback multiuser diversity systems. We propose also a novel proportional fair multiuser switched-based scheduling scheme and we demonstrate that it can be optimized using a practical and distributed method to obtain the feedback thresholds. We finally demonstrate by numerical examples that switched-diversity scheduling schemes operate within 0.3 bits/sec/Hz from the ultimate network capacity of full feedback systems in Rayleigh fading conditions. © 2012 IEEE.

  7. High voltage MOSFET switching circuit

    Science.gov (United States)

    McEwan, Thomas E.

    1994-01-01

    The problem of source lead inductance in a MOSFET switching circuit is compensated for by adding an inductor to the gate circuit. The gate circuit inductor produces an inductive spike which counters the source lead inductive drop to produce a rectangular drive voltage waveform at the internal gate-source terminals of the MOSFET.

  8. Structural health monitoring of high voltage electrical switch ceramic insulators in seismic areas

    OpenAIRE

    REBILLAT, Marc; BARTHES, Clément; MECHBAL, Nazih; MOSALAM, Khalid M.

    2014-01-01

    International audience; High voltage electrical switches are crucial components to restart rapidly the electrical network right after an earthquake. But there currently exists no automatic procedure to check if these ceramic insulators have suffered after an earthquake, and there exists no method to recertify a given switch. To deploy a vibration-based structural health monitoring method on ceramic insulators a large shake table able to generate accelerations up to 3 g was used. The idea unde...

  9. A Novel Application of Zero-Current-Switching Quasiresonant Buck Converter for Battery Chargers

    OpenAIRE

    Kuo-Kuang Chen

    2011-01-01

    The main purpose of this paper is to develop a novel application of a resonant switch converter for battery chargers. A zero-current-switching (ZCS) converter with a quasiresonant converter (QRC) was used as the main structure. The proposed ZCS dc–dc battery charger has a straightforward structure, low cost, easy control, and high efficiency. The operating principles and design procedure of the proposed charger are thoroughly analyzed. The optimal values of the resonant components are compute...

  10. dc analysis and design of zero-voltage-switched multi-resonant converters

    Science.gov (United States)

    Tabisz, Wojciech A.; Lee, Fred C.

    Recently introduced multiresonant converters (MRCs) provide zero-voltage switching (ZVS) of both active and passive switches and offer a substantial reduction of transistor voltage stress and an increase of load range, compared to their quasi-resonant converter counterparts. Using the resonant switch concept, a simple, generalized analysis of ZVS MRCs is presented. The conversion ratio and voltage stress characteristics are derived for basic ZVS MRCs, including buck, boost, and buck/boost converters. Based on the analysis, a design procedure that optimizes the selection of resonant elements for maximum conversion efficiency is proposed.

  11. Heterodiazocines: Synthesis and Photochromic Properties, Trans to Cis Switching within the Bio-optical Window.

    Science.gov (United States)

    Hammerich, Melanie; Schütt, Christian; Stähler, Cosima; Lentes, Pascal; Röhricht, Fynn; Höppner, Ronja; Herges, Rainer

    2016-10-04

    Diazocines, bridged azobenzenes, exhibit superior photophysical properties compared to parent azobenzenes such as high switching efficiencies, quantum yields, and particularly switching wavelengths in the visible range. Synthesis, however, proceeds with low yields, and derivatives are difficult to prepare. We now present two heterodiazocines which are easier to synthesize, and the general procedures should also provide facile access to derivatives. Moreover, both compounds can be switched with light in the far-red (650 nm). Accessibility and photophysical properties make them ideal candidates for applications such as photoswitchable drugs and functional materials.

  12. ARTERIAL REVASCULARIZATION WITH THE RIGHT GASTROEPIPLOIC ARTERY AND INTERNAL MAMMARY ARTERIES IN 300 PATIENTS

    NARCIS (Netherlands)

    GRANDJEAN, JG; BOONSTRA, PW; DENHEYER, P; EBELS, T; KIRKLIN, JW

    From September 1989 to September 1992, the right gastroepiploic artery in combination with one or both internal mammary arteries was used as a graft in 300 patients who underwent coronary artery bypass grafting. The gastroepiploic artery was the primary choice in preference to the saphenous vein.

  13. Radiofrequency Ablation Using a Multiple-Electrode Switching System for Lung Tumors with 2.0-5.0-cm Maximum Diameter: Phase II Clinical Study.

    Science.gov (United States)

    Kodama, Hiroshi; Yamakado, Koichiro; Hasegawa, Takaaki; Fujimori, Masashi; Yamanaka, Takashi; Takaki, Haruyuki; Uraki, Junji; Nakatsuka, Atsuhiro; Sakuma, Hajime

    2015-12-01

    To prospectively evaluate the safety and effectiveness of radiofrequency ablation (RFA) by using a multiple-electrode switching system to treat 2.0-5.0-cm lung tumors. The institutional review board approved this prospective phase II study. Written informed consent was obtained from all patients. Between September 2009 and July 2011, RFA using two or three radiofrequency (RF) electrodes and a multiple-electrode switching system was performed for malignant lung tumors with a maximum tumor diameter of 2.0-5.0 cm in nonsurgical candidates. The primary endpoint was safety, as evaluated using the Common Terminology Criteria for Adverse Events. Patients were observed for at least 1 year. Local tumor progression and overall survival were analyzed with the Kaplan-Meier method. Thirty-three patients (26 men, seven women; mean age, 70.5 years ± 10.0; age range, 46-87 years) with 35 lung tumors with a mean maximum diameter of 3.0 cm ± 0.7 (standard deviation; range, 2.0-4.4 cm) underwent treatment in 35 sessions. No procedure-related death or grade 4 adverse events (AEs) occurred. Grade 3 AEs occurred in four patients (12%), with pleural effusion requiring chest tube placement in two patients, pneumothorax requiring pleural adhesion in one patient, and pulmonary hemorrhage requiring pulmonary artery coil embolization in one patient. Grade 2 AEs were detected in 13 patients (39%). The 1-year local tumor progression and overall survival rates were 12.7% (95% confidence interval [CI]: 1.0, 25.5) and 81.2% (95% CI: 67.6, 94.8). RFA with a multiple-electrode switching system may be a safe therapeutic option with which to treat 2.0-5.0-cm lung cancer tumors.

  14. Endovascular treatment of renal artery stenoses

    International Nuclear Information System (INIS)

    Lashari, M.N.

    2015-01-01

    To evaluate the procedure success and effect on hypertension after stenting of incidentally diagnosed atherosclerotic renal artery stenoses. Study Design: An experimental study. Place and Duration of Study: A multicentric study was conducted at the Plastic Surgery and General Hospital, National Medical Center and Ziauddin University Hospital, Karachi, Pakistan from January 2009 to March 2013. Methodology: Hypertension (systolic blood pressure > 160 and diastolic > 90 mmHg with two or more than two medications) with coronary artery disease were initially evaluated for coronary angiography, Renal artery angiography was also endovascular performed and stent was deployed for atherosclerotic renal artery stenosis when found. Blood pressure readings, reduction in need of antihypertensive medication and serum creatinine levels were taken as outcome measures. Patients having renal artery stenoses secondary to connective tissue disorders and fibromuscular dysplasia were excluded. Results: There were 25 patients, 14 (56%) male and 11 (44%) female, with mean age of 49 +- 6 years. Diabetes mellitus, dyslipidemia and smoking were seen in 11 (44%), 10 (40%) and 4 (16%) patients respectively. Renal insufficiency (serum creatinine > 1.5 mg/dl) was seen in one (04%) patient. Bilateral, and isolated right and left renal artery stenoses was seen in 5 (20%), 9 (36%) and 11(44%) patients respectively. Mean percentage of renal artery stenoses was 89%, ranged from 70% to 99% while ostial lesion was found in 20 (80%) patients. A significant decrease in systolic (168.20 +- 9.987 vs. 140.60 +- 5.649 mmHg, p < 0.001) and diastolic blood pressure (88.60 +- 5.50 vs. 77.20 +- 5.017 mmHg, p < 0.001) and reduction of medication (2.72 +- 0.458 vs. 1.5 +- 0.510, p < 0.01) were noted without a change in renal function (p= 0.061) after renal artery stenting. Conclusion: Endovascular stenting of renal artery stenoses in patients with poorly controlled hypertension is a safe and effective treatment

  15. Switch-connected HyperX network

    Science.gov (United States)

    Chen, Dong; Heidelberger, Philip

    2018-02-13

    A network system includes a plurality of sub-network planes and global switches. The sub-network planes have a same network topology as each other. Each of the sub-network planes includes edge switches. Each of the edge switches has N ports. Each of the global switches is configured to connect a group of edge switches at a same location in the sub-network planes. In each of the sub-network planes, some of the N ports of each of the edge switches are connected to end nodes, and others of the N ports are connected to other edge switches in the same sub-network plane, other of the N ports are connected to at least one of the global switches.

  16. New therapies for arterial hypertension.

    Science.gov (United States)

    Pagliaro, Beniamino; Santolamazza, Caterina; Rubattu, Speranza; Volpe, Massimo

    2016-03-01

    Arterial hypertension is the most common chronic disease in developed countries and it is the leading risk factor for stroke, ischemic heart disease, congestive heart failure, chronic renal failure and peripheral artery disease. Its prevalence appears to be about 30-45% of the general population. Recent European guidelines estimate that up to 15-20% of the hypertensive patients are not controlled on a dual antihypertensive combination and they require three or more different antihypertensive drug classes to achieve adequate blood pressure control. The guidelines confirmed that diuretics, beta-blockers, calcium-channel blockers, angiotensin-converting enzyme inhibitors and angiotensin receptor blockers are suitable for the initiation and maintenance of antihypertensive treatment, either as monotherapy or in combination therapy. Very few antihypertensive agents have reached the market over the last few years, but no new therapeutic class has really emerged. The long-term adherence to cardiovascular drugs is still low in both primary and secondary prevention of cardiovascular diseases. In particular, the issue of compliance is persistently high in hypertension, despite the fixed-dose combination therapy. As a consequence, a cohort of high-risk hypertensive population, represented by patients affected by refractory and resistant hypertension, can be identified. Therefore, the need of controlling BP in high-risk patients may be addressed, in part, by the development of new drugs, devices and procedures that are designed to treat hypertension and comorbidities. In this review we will comprehensively discuss the current literature on recent therapeutic advances in hypertension, including both medical therapy and interventional procedures.

  17. Follow-up of renal and mesenteric artery revascularization with duplex ultrasonography

    Science.gov (United States)

    Taylor, David C.; Houston, Gordon T.M.; Anderson, Caroline; Jameson, Margot; Popatia, Shelley

    1996-01-01

    Objective To evaluate the long-term anatomic results of renal revascularization procedures using duplex ultrasonography. Design A case series. Setting A university-affiliated hospital. Patients Twenty-five patients who had undergone renal percutaneous transluminal angioplasty (PTA) (18 arteries), renal bypass (10 arteries) and mesenteric bypass (6 arteries). The mean follow-up was 22 months (range from 3 to 48 months) for those who underwent renal PTA, 23 months (range from 1.5 to 70 months) for those who underwent renal bypass and 34 months (range from 8 to 144 months) for those who underwent mesenteric bypass. Main Outcome Measures Patency rates for the three procedures as assessed by duplex ultrasonography. Results Duplex ultrasonography demonstrated patency without stenosis after renal and mesenteric artery revascularization in 14 arteries subjected to renal PTA, 9 arteries subjected to renal bypass and 6 arteries subjected to mesenteric bypass. Three arteries that had renal PTA had recurrent vessel stenosis and one had occlusion. One artery that had renal bypass showed occlusion. Conclusions Renal PTA, renal bypass and mesenteric bypass are durable procedures at 2 years of follow-up, and duplex ultrasonography is a valuable method for assessing the patency of arteries after renal and mesenteric revascularization. PMID:8599785

  18. Early results of coronary artery bypass grafting with coronary endarterectomy for severe coronary artery disease

    Directory of Open Access Journals (Sweden)

    Toischer Karl

    2009-09-01

    failure: 3; stroke: 1; cancer: 1; unknown reasons: 3. NYHA-classification significantly improved after CABG with CE from 2.2 ± 0.9 preoperative to 1.7 ± 0.9 postoperative. CCS also changed from 2.4 ± 1.0 to 1.5 ± 0.8 Conclusion Early results of coronary endarterectomy are acceptable with respect to mortality, NYHA & CCS. This technique offers a valuable surgical option for patients with endstage coronary artery disease in whom complete revascularization otherwise can not be obtained. Careful patient selection will be necessary to assure the long-term benefit of this procedure.

  19. Bronchial arteries: an arteriosclerosis-resistant circulation.

    Science.gov (United States)

    Kotoulas, Christophoros; Melachrinou, Maria; Konstantinou, George N; Alexopoulos, Dimitrios; Dougenis, Dimitrios

    2010-01-01

    Until now, it is unknown whether and to what extent arteriosclerotic disease affects the bronchial arteries. We conducted this pilot study to estimate the prevalence of arteriosclerosis of the bronchial arteries, to correlate it with certain clinicolaboratory arteriosclerotic parameters or any coexistent coronary artery disease (CAD) and to validate the clinical significance. Bronchial arteries 10-15 mm long were obtained from 40 patients with a mean age of 62.3 years who underwent major thoracic procedures. Their medical history and detailed clinical and laboratory arteriosclerotic risk factors were documented. The mean diameter of bronchial artery specimens was 0.97 mm. Histology revealed medial calcific sclerosis only in 1 patient (2.5%) without simultaneous, established atherosclerotic lesions or narrowing of the lumen. Furthermore, the vessel diameter was significantly correlated not only with the advanced stage of the disease (p = 0.031), but also with the proximal occlusion of the bronchial tree (p = 0.042). We noted a marginally not significant correlation between arteriosclerosis and metabolic syndrome (p = 0.075), independent from a history of CAD (p = 0.84). Bronchial arteries exhibit only medial calcific sclerosis. CAD and chronic obstructive pulmonary disease do not seem to affect them in terms of atherosclerotic alteration findings or vessel diameter changes. The bronchial resistance to arteriosclerosis might support the mediastinal status quo through their anastomoses, contributing to all its structures, and might be indirect evidence of a different physiological function of the bronchial endothelium, which needs to be further investigated. Copyright 2009 S. Karger AG, Basel.

  20. Isolated converter with synchronized switching leg

    NARCIS (Netherlands)

    2003-01-01

    An amplification device is disclosed providing a way of integrating a switch mode power supply and a class D amplifier (switch mode amplifier). This results in the usage of basically one magnetic component (1), one major energy storage element (4) and switches (20, 30) that are controlled in such a

  1. Mechanism of single atom switch on silicon

    DEFF Research Database (Denmark)

    Quaade, Ulrich; Stokbro, Kurt; Thirstrup, C.

    1998-01-01

    We demonstrate single atom switch on silicon which operates by displacement of a hydrogen atom on the silicon (100) surface at room temperature. We find two principal effects by which the switch is controlled: a pronounced maximum of the switching probability as function of sample bias...

  2. A CW Gunn diode bistable switching element.

    Science.gov (United States)

    Hurtado, M.; Rosenbaum, F. J.

    1972-01-01

    Experiments with a current-controlled bistable switching element using a CW Gunn diode are reported. Switching rates of the order of 10 MHz have been obtained. Switching is initiated by current pulses of short duration (5-10 ns). Rise times of the order of several nanoseconds could be obtained.

  3. A gain-coefficient switched Alexandrite laser

    International Nuclear Information System (INIS)

    Lee, Chris J; Van der Slot, Peter J M; Boller, Klaus-J

    2013-01-01

    We report on a gain-coefficient switched Alexandrite laser. An electro-optic modulator is used to switch between high and low gain states by making use of the polarization dependent gain of Alexandrite. In gain-coefficient switched mode, the laser produces 85 ns pulses with a pulse energy of 240 mJ at a repetition rate of 5 Hz.

  4. 47 CFR 69.106 - Local switching.

    Science.gov (United States)

    2010-10-01

    ... foreign services that use local exchange switching facilities. (c) If end users of an interstate or... local exchange carriers shall establish rate elements for local switching as follows: (1) Price cap... use local exchange switching facilities for the provision of interstate or foreign services. The...

  5. Caffeine improves anticipatory processes in task switching

    NARCIS (Netherlands)

    Tieges, Zoe; Snel, Jan; Kok, Albert; Wijnen, Jasper G.; Lorist, Monicque M.; Ridderinkhof, K. Richard

    We studied the effects of moderate amounts of caffeine on task switching and task maintenance using mixed-task (AABB) blocks, in which participants alternated predictably between two tasks, and single-task (AAAA, BBBB) blocks. Switch costs refer to longer reaction times (RT) on task switch trials

  6. Bootstrapped Low-Voltage Analog Switches

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    1999-01-01

    Novel low-voltage constant-impedance analog switch circuits are proposed. The switch element is a single MOSFET, and constant-impedance operation is obtained using simple circuits to adjust the gate and bulk voltages relative to the switched signal. Low-voltage (1-volt) operation is made feasible...

  7. Control and synchronisation in switched arrival systems

    NARCIS (Netherlands)

    Rem, B.; Armbruster, H.D.

    2003-01-01

    A chaotic model of a production flow called the switched arrival system is extended to include switching times and maintenance. The probability distribution of the chaotic return times is calculated. Scheduling maintenance, loss of production due to switching, and control of the chaotic dynamics is

  8. Input and output constraints-based stabilisation of switched nonlinear systems with unstable subsystems and its application

    Science.gov (United States)

    Chen, Chao; Liu, Qian; Zhao, Jun

    2018-01-01

    This paper studies the problem of stabilisation of switched nonlinear systems with output and input constraints. We propose a recursive approach to solve this issue. None of the subsystems are assumed to be stablisable while the switched system is stabilised by dual design of controllers for subsystems and a switching law. When only dealing with bounded input, we provide nested switching controllers using an extended backstepping procedure. If both input and output constraints are taken into consideration, a Barrier Lyapunov Function is employed during operation to construct multiple Lyapunov functions for switched nonlinear system in the backstepping procedure. As a practical example, the control design of an equilibrium manifold expansion model of aero-engine is given to demonstrate the effectiveness of the proposed design method.

  9. Repeated Intra-Arterial Thrombectomy within 72 Hours in a Patient with a Clear Contraindication for Intravenous Thrombolysis

    Directory of Open Access Journals (Sweden)

    Mona Laible

    2015-01-01

    Full Text Available Introduction. Treating patients with acute ischemic stroke, proximal arterial vessel occlusion, and absolute contraindication for administering intravenous recombinant tissue plasminogen activator (rtPA poses a therapeutic challenge. Intra-arterial thrombectomy constitutes an alternative treatment option. Materials and Methods. We report a case of a 57-year-old patient with concomitant gastric adenocarcinoma, who received three intra-arterial thrombectomies in 72 hours due to repeated occlusion of the left medial cerebral artery (MCA. Findings. Intra-arterial recanalization of the left medial cerebral artery was performed three times with initially good success. However, two days later, the right medial cerebral artery became occluded. Owing to the overall poor prognosis at that time and knowing the wishes of the patient, we decided not to perform another intra-arterial recanalization procedure. Conclusion. To our knowledge, this is the first case illustrating the use of repeated intra-arterial recanalization in early reocclusion of intracranial vessels.

  10. Environmental procedures

    International Nuclear Information System (INIS)

    1992-01-01

    The European Bank has pledged in its Agreement to place environmental management at the forefront of its operations to promote sustainable economic development in central and eastern Europe. The Bank's environmental policy is set out in the document titled, Environmental Management: The Bank's Policy Approach. This document, Environmental Procedures, presents the procedures which the European Bank has adopted to implement this policy approach with respect to its operations. The environmental procedures aim to: ensure that throughout the project approval process, those in positions of responsibility for approving projects are aware of the environmental implications of the project, and can take these into account when making decisions; avoid potential liabilities that could undermine the success of a project for its sponsors and the Bank; ensure that environmental costs are estimated along with other costs and liabilities; and identify opportunities for environmental enhancement associated with projects. The review of environmental aspects of projects is conducted by many Bank staff members throughout the project's life. This document defines the responsibilities of the people and groups involved in implementing the environmental procedures. Annexes contain Environmental Management: The Bank's Policy Approach, examples of environmental documentation for the project file and other ancillary information

  11. Optimization of multi-branch switched diversity systems

    KAUST Repository

    Nam, Haewoon; Alouini, Mohamed-Slim

    2009-01-01

    A performance optimization based on the optimal switching threshold(s) for a multi-branch switched diversity system is discussed in this paper. For the conventional multi-branch switched diversity system with a single switching threshold

  12. Electronic logic to enhance switch reliability in detecting openings and closures of redundant switches

    Science.gov (United States)

    Cooper, James A.

    1986-01-01

    A logic circuit is used to enhance redundant switch reliability. Two or more switches are monitored for logical high or low output. The output for the logic circuit produces a redundant and failsafe representation of the switch outputs. When both switch outputs are high, the output is high. Similarly, when both switch outputs are low, the logic circuit's output is low. When the output states of the two switches do not agree, the circuit resolves the conflict by memorizing the last output state which both switches were simultaneously in and produces the logical complement of this output state. Thus, the logic circuit of the present invention allows the redundant switches to be treated as if they were in parallel when the switches are open and as if they were in series when the switches are closed. A failsafe system having maximum reliability is thereby produced.

  13. Atherectomy for peripheral arterial disease.

    Science.gov (United States)

    Ambler, Graeme K; Radwan, Rami; Hayes, Paul D; Twine, Christopher P

    2014-03-17

    Symptomatic peripheral arterial disease may be treated by a number of options including exercise therapy, angioplasty, stenting and bypass surgery. Atherectomy is an alternative technique where atheroma is excised by a rotating cutting blade. The objective of this review was to analyse randomised controlled trials comparing atherectomy against any established treatment for peripheral arterial disease in order to evaluate the effectiveness of atherectomy. The Cochrane Peripheral Vascular Diseases Group Trials Search Co-ordinator searched the Specialised Register (last searched November 2013) and CENTRAL (2013, Issue 10). Trials databases were searched for details of ongoing or unpublished studies. Randomised controlled trials (RCTs) comparing atherectomy and other established treatments were selected for inclusion. All participants had symptomatic peripheral arterial disease with either claudication or critical limb ischaemia and evidence of lower limb arterial disease. Two review authors (GA and CT) screened studies for inclusion, extracted data and assessed the quality of the trials. Any disagreements were resolved through discussion. Four trials were included with a total of 220 participants (118 treated with atherectomy, 102 treated with balloon angioplasty) and 259 treated vessels (129 treated with atherectomy, 130 treated with balloon angioplasty). All studies compared atherectomy with angioplasty. No study was properly powered or assessors blinded to the procedures and there was a high risk of selection, attrition, detection and reporting biases.The estimated risk of success was similar between the treatment modalities although the confidence interval (CI) was compatible with small benefits of either treatment for the initial procedural success rate (Mantel-Haenszel risk ratio (RR) 0.92, 95% CI 0.44 to 1.91, P = 0.82), patency at six months (Mantel-Haenszel RR 0.92, 95% CI 0.51 to 1.66, P = 0.79) and patency at 12 months (Mantel-Haenszel RR 1.17, 95% CI 0

  14. Mechanical design in arteries.

    Science.gov (United States)

    Shadwick, R E

    1999-12-01

    The most important mechanical property of the artery wall is its non-linear elasticity. Over the last century, this has been well-documented in vessels in many animals, from humans to lobsters. Arteries must be distensible to provide capacitance and pulse-smoothing in the circulation, but they must also be stable to inflation over a range of pressure. These mechanical requirements are met by strain-dependent increases in the elastic modulus of the vascular wall, manifest by a J-shaped stress-strain curve, as typically exhibited by other soft biological tissues. All vertebrates and invertebrates with closed circulatory systems have arteries with this non-linear behaviour, but specific tissue properties vary to give correct function for the physiological pressure range of each species. In all cases, the non-linear elasticity is a product of the parallel arrangement of rubbery and stiff connective tissue elements in the artery wall, and differences in composition and tissue architecture can account for the observed variations in mechanical properties. This phenomenon is most pronounced in large whales, in which very high compliance in the aortic arch and exceptionally low compliance in the descending aorta occur, and is correlated with specific modifications in the arterial structure.

  15. “Transcollateral” Renal Angioplasty for a Completely Occluded Renal Artery

    International Nuclear Information System (INIS)

    Chandra, Subash; Chadha, Davinder S.; Swamy, Ajay

    2011-01-01

    Percutaneous transluminal renal angioplasty with stenting has been effective in the control of hypertension, renal function, and pulmonary edema caused by atherosclerotic renal artery stenosis. However, the role of the procedure has not been fully established in the context of chronic total occlusion of renal artery. We report the successful use of this procedure in 57-year-old male patient who reported for evaluation of a recent episode of accelerated hypertension. A renal angiogram in this patient showed ostial stenosis of the right renal artery, which was filling by way of the collateral artery. Renal angioplasty for chronic total occlusion of right renal artery was successfully performed in a retrograde fashion through a collateral artery, thereby leading to improvement of renal function and blood pressure control.

  16. Traumatic Distal Ulnar Artery Thrombosis

    Directory of Open Access Journals (Sweden)

    Ahmet A. Karaarslan

    2014-01-01

    Full Text Available This paper is about a posttraumatic distal ulnar artery thrombosis case that has occurred after a single blunt trauma. The ulnar artery thrombosis because of chronic trauma is a frequent condition (hypothenar hammer syndrome but an ulnar artery thrombosis because of a single direct blunt trauma is rare. Our patient who has been affected by a single blunt trauma to his hand and developed ulnar artery thrombosis has been treated by resection of the thrombosed ulnar artery segment. This report shows that a single blunt trauma can cause distal ulnar artery thrombosis in the hand and it can be treated merely by thrombosed segment resection in suitable cases.

  17. Large aperture optical switching devices

    International Nuclear Information System (INIS)

    Goldhar, J.; Henesian, M.A.

    1983-01-01

    We have developed a new approach to constructing large aperture optical switches for next generation inertial confinement fusion lasers. A transparent plasma electrode formed in low pressure ionized gas acts as a conductive coating to allow the uniform charging of the optical faces of an electro-optic material. In this manner large electric fields can be applied longitudinally to large aperture, high aspect ratio Pockels cells. We propose a four-electrode geometry to create the necessary high conductivity plasma sheets, and have demonstrated fast (less than 10 nsec) switching in a 5x5 cm aperture KD*P Pockels cell with such a design. Detaid modelling of Pockels cell performance with plasma electrodes has been carried out for 15 and 30 cm aperture designs

  18. Shape memory thermal conduction switch

    Science.gov (United States)

    Vaidyanathan, Rajan (Inventor); Krishnan, Vinu (Inventor); Notardonato, William U. (Inventor)

    2010-01-01

    A thermal conduction switch includes a thermally-conductive first member having a first thermal contacting structure for securing the first member as a stationary member to a thermally regulated body or a body requiring thermal regulation. A movable thermally-conductive second member has a second thermal contacting surface. A thermally conductive coupler is interposed between the first member and the second member for thermally coupling the first member to the second member. At least one control spring is coupled between the first member and the second member. The control spring includes a NiTiFe comprising shape memory (SM) material that provides a phase change temperature <273 K, a transformation range <40 K, and a hysteresis of <10 K. A bias spring is between the first member and the second member. At the phase change the switch provides a distance change (displacement) between first and second member by at least 1 mm, such as 2 to 4 mm.

  19. Negation switching invariant signed graphs

    Directory of Open Access Journals (Sweden)

    Deepa Sinha

    2014-04-01

    Full Text Available A signed graph (or, $sigraph$ in short is a graph G in which each edge x carries a value $\\sigma(x \\in \\{-, +\\}$ called its sign. Given a sigraph S, the negation $\\eta(S$ of the sigraph S is a sigraph obtained from S by reversing the sign of every edge of S. Two sigraphs $S_{1}$ and $S_{2}$ on the same underlying graph are switching equivalent if it is possible to assign signs `+' (`plus' or `-' (`minus' to vertices of $S_{1}$ such that by reversing the sign of each of its edges that has received opposite signs at its ends, one obtains $S_{2}$. In this paper, we characterize sigraphs which are negation switching invariant and also see for what sigraphs, S and $\\eta (S$ are signed isomorphic.

  20. Switch for Good Community Program

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, Tabitha [Balfour Beatty Military Housing Management LLC, Newtown Square, PA (United States); Amran, Martha [WattzOn, Inc., Mountain View, CA (United States)

    2013-11-19

    Switch4Good is an energy-savings program that helps residents reduce consumption from behavior changes; it was co-developed by Balfour Beatty Military Housing Management (BB) and WattzOn in Phase I of this grant. The program was offered at 11 Navy bases. Three customer engagement strategies were evaluated, and it was found that Digital Nudges (a combination of monthly consumption statements with frequent messaging via text or email) was most cost-effective. The program was delivered on-time and on-budget, and its success is based on the teamwork of local BB staff and the WattzOn team. The following graphic shows Switch4Good “by the numbers”, e.g. the scale of operations achieved during Phase I.

  1. 40 CFR 1065.12 - Approval of alternate procedures.

    Science.gov (United States)

    2010-07-01

    ... Compliance Officer an initial written request describing the alternate procedure and why you believe it is... described in this section, we may ask you to submit to us in writing supplemental information showing that... allowed procedure, considering the following factors: (1) The cost, difficulty, and availability to switch...

  2. Pulsed laser triggered high speed microfluidic switch

    Science.gov (United States)

    Wu, Ting-Hsiang; Gao, Lanyu; Chen, Yue; Wei, Kenneth; Chiou, Pei-Yu

    2008-10-01

    We report a high-speed microfluidic switch capable of achieving a switching time of 10 μs. The switching mechanism is realized by exciting dynamic vapor bubbles with focused laser pulses in a microfluidic polydimethylsiloxane (PDMS) channel. The bubble expansion deforms the elastic PDMS channel wall and squeezes the adjacent sample channel to control its fluid and particle flows as captured by the time-resolved imaging system. A switching of polystyrene microspheres in a Y-shaped channel has also been demonstrated. This ultrafast laser triggered switching mechanism has the potential to advance the sorting speed of state-of-the-art microscale fluorescence activated cell sorting devices.

  3. Secure videoconferencing equipment switching system and method

    Science.gov (United States)

    Hansen, Michael E [Livermore, CA

    2009-01-13

    A switching system and method are provided to facilitate use of videoconference facilities over a plurality of security levels. The system includes a switch coupled to a plurality of codecs and communication networks. Audio/Visual peripheral components are connected to the switch. The switch couples control and data signals between the Audio/Visual peripheral components and one but nor both of the plurality of codecs. The switch additionally couples communication networks of the appropriate security level to each of the codecs. In this manner, a videoconferencing facility is provided for use on both secure and non-secure networks.

  4. Brachial artery approach for outpatient arteriography

    International Nuclear Information System (INIS)

    You, Jai Kyung; Park, Sung Il; Lee, Do Yun; Won, Jae Hwan

    1999-01-01

    To evaluate the diagnostic usefulness of brachial approach arteriography for outpatients, with particular regard to safety and image quality. The angiographic findings and follow-up medical records of 131 brachial approach arteriographies in 121 outpatients were retrospectively analysed. 5 F pigtail catheters were used in 125 cases and 5-F OCU-A catheters were used in three cases of renal arteriography, and three of upper extremity arteriography without catheter. Except for three cases of brachial artery puncture failure, all procedures were performed successfully. One hundred and fifteen of 119 lower extremity arteriographies were visualized down to the level of the tibioperoneal artery. The non-visualized cases were three in which there was multiple obstruction at the distal common iliac artery and one with insufficient contrast amount due to renal failure In four cases there were complications : two involved arterial thrombosis, one was an intramuscular hematoma, and one an A-V fistula. For outpatients, brachial approach arteriography can replace the femoral approach. Its image quality is excellent, there are time-cost benefits, and the rate of complications is relatively low

  5. Uterine artery embolization for adenomyosis without fibroids

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M.D. E-mail: mdkim@cha.ac.kr; Won, J.W.; Lee, D.Y.; Ahn, C.-S

    2004-06-01

    AIM: To evaluate the potential usefulness of transcatheter uterine artery embolization as a treatment for symptomatic adenomyosis in patients without uterine fibroids. MATERIALS AND METHODS: Uterine artery embolization using polyvinyl alcohol particles sized 250-710 mm was performed in 43 patients (mean; 40.3 years, range; 31-52 years) with dysmenorrhoea, menorrhagia, or bulk-related symptoms (pelvic heaviness, urinary frequency) due to adenomyosis without fibroids. All patients underwent pre-procedural and 3.5 months (range 1-8 months) follow-up magnetic resonance imaging (MRI) with contrast enhancement. Clinical symptoms were also assessed at the time of MRI before and after embolization. RESULTS: Significant improvement of dysmenorrhoea (95.2%) and menorrhagia (95.0%) was reported in most patients. Contrast-enhanced MRI revealed non-enhancing areas suggesting coagulation necrosis of adenomyosis in 31 patients (72.1%), decreased size without necrosis in 11 patients (25.6%), and no change in one patient (2.3%). The mean volume reduction of the uteri after uterine artery embolization was 32.5% (from 321.7{+-}142.9 to 216.7{+-}130.1 cm{sup 3}). CONCLUSION: Transcatheter uterine artery embolization is an effective therapy for the treatment of symptomatic pure adenomyosis, and may be a valuable alternative to hysterectomy.

  6. Uterine artery embolization for adenomyosis without fibroids

    International Nuclear Information System (INIS)

    Kim, M.D.; Won, J.W.; Lee, D.Y.; Ahn, C.-S.

    2004-01-01

    AIM: To evaluate the potential usefulness of transcatheter uterine artery embolization as a treatment for symptomatic adenomyosis in patients without uterine fibroids. MATERIALS AND METHODS: Uterine artery embolization using polyvinyl alcohol particles sized 250-710 mm was performed in 43 patients (mean; 40.3 years, range; 31-52 years) with dysmenorrhoea, menorrhagia, or bulk-related symptoms (pelvic heaviness, urinary frequency) due to adenomyosis without fibroids. All patients underwent pre-procedural and 3.5 months (range 1-8 months) follow-up magnetic resonance imaging (MRI) with contrast enhancement. Clinical symptoms were also assessed at the time of MRI before and after embolization. RESULTS: Significant improvement of dysmenorrhoea (95.2%) and menorrhagia (95.0%) was reported in most patients. Contrast-enhanced MRI revealed non-enhancing areas suggesting coagulation necrosis of adenomyosis in 31 patients (72.1%), decreased size without necrosis in 11 patients (25.6%), and no change in one patient (2.3%). The mean volume reduction of the uteri after uterine artery embolization was 32.5% (from 321.7±142.9 to 216.7±130.1 cm 3 ). CONCLUSION: Transcatheter uterine artery embolization is an effective therapy for the treatment of symptomatic pure adenomyosis, and may be a valuable alternative to hysterectomy

  7. Switching strategies to optimize search

    International Nuclear Information System (INIS)

    Shlesinger, Michael F

    2016-01-01

    Search strategies are explored when the search time is fixed, success is probabilistic and the estimate for success can diminish with time if there is not a successful result. Under the time constraint the problem is to find the optimal time to switch a search strategy or search location. Several variables are taken into account, including cost, gain, rate of success if a target is present and the probability that a target is present. (paper: interdisciplinary statistical mechanics)

  8. Correlated randomness and switching phenomena

    Science.gov (United States)

    Stanley, H. E.; Buldyrev, S. V.; Franzese, G.; Havlin, S.; Mallamace, F.; Kumar, P.; Plerou, V.; Preis, T.

    2010-08-01

    One challenge of biology, medicine, and economics is that the systems treated by these serious scientific disciplines have no perfect metronome in time and no perfect spatial architecture-crystalline or otherwise. Nonetheless, as if by magic, out of nothing but randomness one finds remarkably fine-tuned processes in time and remarkably fine-tuned structures in space. Further, many of these processes and structures have the remarkable feature of “switching” from one behavior to another as if by magic. The past century has, philosophically, been concerned with placing aside the human tendency to see the universe as a fine-tuned machine. Here we will address the challenge of uncovering how, through randomness (albeit, as we shall see, strongly correlated randomness), one can arrive at some of the many spatial and temporal patterns in biology, medicine, and economics and even begin to characterize the switching phenomena that enables a system to pass from one state to another. Inspired by principles developed by A. Nihat Berker and scores of other statistical physicists in recent years, we discuss some applications of correlated randomness to understand switching phenomena in various fields. Specifically, we present evidence from experiments and from computer simulations supporting the hypothesis that water’s anomalies are related to a switching point (which is not unlike the “tipping point” immortalized by Malcolm Gladwell), and that the bubbles in economic phenomena that occur on all scales are not “outliers” (another Gladwell immortalization). Though more speculative, we support the idea of disease as arising from some kind of yet-to-be-understood complex switching phenomenon, by discussing data on selected examples, including heart disease and Alzheimer disease.

  9. Pelvic Arterial Anatomy Relevant to Prostatic Artery Embolisation and Proposal for Angiographic Classification

    Energy Technology Data Exchange (ETDEWEB)

    Assis, André Moreira de, E-mail: andre.maa@gmail.com; Moreira, Airton Mota, E-mail: motamoreira@gmail.com; Paula Rodrigues, Vanessa Cristina de, E-mail: vanessapaular@yahoo.com.br [University of Sao Paulo Medical School, Interventional Radiology and Endovascular Surgery Department, Radiology Institute (Brazil); Harward, Sardis Honoria, E-mail: sardis.harward@merit.com [The Dartmouth Center for Health Care Delivery Science (United States); Antunes, Alberto Azoubel, E-mail: antunesuro@uol.com.br; Srougi, Miguel, E-mail: srougi@usp.br [University of Sao Paulo Medical School, Urology Department (Brazil); Carnevale, Francisco Cesar, E-mail: fcarnevale@uol.com.br [University of Sao Paulo Medical School, Interventional Radiology and Endovascular Surgery Department, Radiology Institute (Brazil)

    2015-08-15

    PurposeTo describe and categorize the angiographic findings regarding prostatic vascularization, propose an anatomic classification, and discuss its implications for the PAE procedure.MethodsAngiographic findings from 143 PAE procedures were reviewed retrospectively, and the origin of the inferior vesical artery (IVA) was classified into five subtypes as follows: type I: IVA originating from the anterior division of the internal iliac artery (IIA), from a common trunk with the superior vesical artery (SVA); type II: IVA originating from the anterior division of the IIA, inferior to the SVA origin; type III: IVA originating from the obturator artery; type IV: IVA originating from the internal pudendal artery; and type V: less common origins of the IVA. Incidences were calculated by percentage.ResultsTwo hundred eighty-six pelvic sides (n = 286) were analyzed, and 267 (93.3 %) were classified into I–IV types. Among them, the most common origin was type IV (n = 89, 31.1 %), followed by type I (n = 82, 28.7 %), type III (n = 54, 18.9 %), and type II (n = 42, 14.7 %). Type V anatomy was seen in 16 cases (5.6 %). Double vascularization, defined as two independent prostatic branches in one pelvic side, was seen in 23 cases (8.0 %).ConclusionsDespite the large number of possible anatomical variations of male pelvis, four main patterns corresponded to almost 95 % of the cases. Evaluation of anatomy in a systematic fashion, following a standard classification, will make PAE a faster, safer, and more effective procedure.

  10. Fast superconducting magnetic field switch

    Science.gov (United States)

    Goren, Yehuda; Mahale, Narayan K.

    1996-01-01

    The superconducting magnetic switch or fast kicker magnet is employed with electron stream or a bunch of electrons to rapidly change the direction of flow of the electron stream or bunch of electrons. The apparatus employs a beam tube which is coated with a film of superconducting material. The tube is cooled to a temperature below the superconducting transition temperature and is subjected to a constant magnetic field which is produced by an external dc magnet. The magnetic field produced by the dc magnet is less than the critical field for the superconducting material, thus, creating a Meissner Effect condition. A controllable fast electromagnet is used to provide a magnetic field which supplements that of the dc magnet so that when the fast magnet is energized the combined magnetic field is now greater that the critical field and the superconducting material returns to its normal state allowing the magnetic field to penetrate the tube. This produces an internal field which effects the direction of motion and of the electron stream or electron bunch. The switch can also operate as a switching mechanism for charged particles.

  11. Fast superconducting magnetic field switch

    International Nuclear Information System (INIS)

    Goren, Y.; Mahale, N.K.

    1996-01-01

    The superconducting magnetic switch or fast kicker magnet is employed with electron stream or a bunch of electrons to rapidly change the direction of flow of the electron stream or bunch of electrons. The apparatus employs a beam tube which is coated with a film of superconducting material. The tube is cooled to a temperature below the superconducting transition temperature and is subjected to a constant magnetic field which is produced by an external dc magnet. The magnetic field produced by the dc magnet is less than the critical field for the superconducting material, thus, creating a Meissner Effect condition. A controllable fast electromagnet is used to provide a magnetic field which supplements that of the dc magnet so that when the fast magnet is energized the combined magnetic field is now greater that the critical field and the superconducting material returns to its normal state allowing the magnetic field to penetrate the tube. This produces an internal field which effects the direction of motion and of the electron stream or electron bunch. The switch can also operate as a switching mechanism for charged particles. 6 figs

  12. Coating possibilities for magnetic switches

    International Nuclear Information System (INIS)

    Sharp, D.J.; Harjes, H.C.; Mann, G.A.; Morgan, F.A.

    1990-01-01

    High average power magnetic pulse compression systems are now being considered for use in several applications such as the High Power Radiation Source (HiPoRS) project. Such systems will require high reliability magnetic switches (saturable inductors) that are very efficient and have long lifetimes. One of the weakest components in magnetic switches is their interlaminar insulation. Considerations related to dielectric breakdown, thermal management of compact designs, and economical approaches for achieving these needs must be addressed. Various dielectric insulation and coating materials have been applied to Metglas foil in an attempt to solve the complex technical and practical problems associated with large magnetic switch structures. This work reports various needs, studies, results, and proposals in selecting and evaluating continuous coating approaches for magnetic foil. Techniques such as electrophoretic polymer deposition and surface chemical oxidation are discussed. We also propose continuous photofabrication processes for applying dielectric ribs or spacers to the foil which permit circulation of dielectric liquids for cooling during repetitive operation. 10 refs., 8 figs., 11 tabs

  13. Analytical Performance Evaluation of Different Switch Solutions

    Directory of Open Access Journals (Sweden)

    Francisco Sans

    2013-01-01

    Full Text Available The virtualization of the network access layer has opened new doors in how we perceive networks. With this virtualization of the network, it is possible to transform a regular PC with several network interface cards into a switch. PC-based switches are becoming an alternative to off-the-shelf switches, since they are cheaper. For this reason, it is important to evaluate the performance of PC-based switches. In this paper, we present a performance evaluation of two PC-based switches, using Open vSwitch and LiSA, and compare their performance with an off-the-shelf Cisco switch. The RTT, throughput, and fairness for UDP are measured for both Ethernet and Fast Ethernet technologies. From this research, we can conclude that the Cisco switch presents the best performance, and both PC-based switches have similar performance. Between Open vSwitch and LiSA, Open vSwitch represents a better choice since it has more features and is currently actively developed.

  14. Streamer model for high voltage water switches

    International Nuclear Information System (INIS)

    Sazama, F.J.; Kenyon, V.L. III

    1979-01-01

    An electrical switch model for high voltage water switches has been developed which predicts streamer-switching effects that correlate well with water-switch data from Casino over the past four years and with switch data from recent Aurora/AMP experiments. Preclosure rounding and postclosure resistive damping of pulseforming line voltage waveforms are explained in terms of spatially-extensive, capacitive-coupling of the conducting streamers as they propagate across the gap and in terms of time-dependent streamer resistance and inductance. The arc resistance of the Casino water switch and of a gas switch under test on Casino was determined by computer fit to be 0.5 +- 0.1 ohms and 0.3 +- 0.06 ohms respectively, during the time of peak current in the power pulse. Energy lost in the water switch during the first pulse is 18% of that stored in the pulseforming line while similar energy lost in the gas switch is 11%. The model is described, computer transient analyses are compared with observed water and gas switch data and the results - switch resistance, inductance and energy loss during the primary power pulse - are presented

  15. Radiochemical procedures

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1982-01-01

    The modern counting instrumentation has largely obviated the need for separation processes in the radiochemical analysis but problems in low-level radioactivity measurement, environmental-type analyses, and special situations caused in the last years a renaissance of the need for separation techniques. Most of the radiochemical procedures, based on the classic works of the Manhattan Project chemists of the 1940's, were published in the National Nuclear Energy Series (NNES). Improvements such as new solvent extraction and ion exchange separations have been added to these methods throughout the years. Recently the Los Alamos Group have reissued their collected Radiochemical Procedures containing a short summary and review of basic inorganic chemistry - 'Chemistry of the Elements on the Basis of Electronic Configuration'. (A.L.)

  16. Successful surgical repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery with prior reconstruction of the carotid artery

    International Nuclear Information System (INIS)

    Miyahara, Ken; Maeda, Masanobu; Sakai, Yoshimasa; Sakurai, Hajime; Murayama, Hiroomi; Hasegawa, Hiroki

    2003-01-01

    We report the successful repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery (BCA) in a 70-year-old man. He had undergone a mediastinal tumor resection through a median sternotomy in 1995. Pathological examination revealed non-Hodgkin's lymphoma. Two years later, he underwent radiation therapy of 65 Gray for metastasis to the supraclavicular lymph nodes. On January 18, 2000, plastic surgeons planned to perform a pectoralis major musculocutaneous flap to repair a radiation skin ulcer. During the operation, the BCA was lacerated, possibly in an area of radiation tissue damage. We performed a prosthetic graft (10-mm Gelseal) replacement of the BCA. The right subclavian artery had to be ligated. Postoperative digital subtraction angiography (DSA) showed excellent reconstruction of the artery. Magnetic resonance angiography of the brain showed a deficit in the anterior communicating artery and stenosis of the posterior communicating artery, which indicated that the reconstruction procedure was reasonable. Seven months later, on August 18, 2000, the patient was transferred to our hospital because of swelling of the right neck and oozing from the previous cutaneous wound. CT scan and DSA demonstrated the presence of a pseudoaneurysm of the proximal anastomosis site, which required emergency surgery. Before this third sternotomy, a saphenous vein graft was interposed between both external carotid arteries. Removal of the prosthetic graft and resection of the pseudoaneurysm were performed under mild hypothermia and cardiopulmonary bypass with left common carotid arterial perfusion. Then, the wound was closed completely using a left pectoralis major musculocutaneous flap. The postoperative course was uneventful and DSA showed good patency of the graft and intracranial arteries. The patient was discharged without neurological complications. We conclude that prior reconstruction of the carotid artery is a safe and effective procedure for patients with

  17. Successful surgical repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery with prior reconstruction of the carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Miyahara, Ken; Maeda, Masanobu; Sakai, Yoshimasa; Sakurai, Hajime; Murayama, Hiroomi; Hasegawa, Hiroki [Social Insurance Chukyo Hospital, Nagoya (Japan)

    2003-01-01

    We report the successful repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery (BCA) in a 70-year-old man. He had undergone a mediastinal tumor resection through a median sternotomy in 1995. Pathological examination revealed non-Hodgkin's lymphoma. Two years later, he underwent radiation therapy of 65 Gray for metastasis to the supraclavicular lymph nodes. On January 18, 2000, plastic surgeons planned to perform a pectoralis major musculocutaneous flap to repair a radiation skin ulcer. During the operation, the BCA was lacerated, possibly in an area of radiation tissue damage. We performed a prosthetic graft (10-mm Gelseal) replacement of the BCA. The right subclavian artery had to be ligated. Postoperative digital subtraction angiography (DSA) showed excellent reconstruction of the artery. Magnetic resonance angiography of the brain showed a deficit in the anterior communicating artery and stenosis of the posterior communicating artery, which indicated that the reconstruction procedure was reasonable. Seven months later, on August 18, 2000, the patient was transferred to our hospital because of swelling of the right neck and oozing from the previous cutaneous wound. CT scan and DSA demonstrated the presence of a pseudoaneurysm of the proximal anastomosis site, which required emergency surgery. Before this third sternotomy, a saphenous vein graft was interposed between both external carotid arteries. Removal of the prosthetic graft and resection of the pseudoaneurysm were performed under mild hypothermia and cardiopulmonary bypass with left common carotid arterial perfusion. Then, the wound was closed completely using a left pectoralis major musculocutaneous flap. The postoperative course was uneventful and DSA showed good patency of the graft and intracranial arteries. The patient was discharged without neurological complications. We conclude that prior reconstruction of the carotid artery is a safe and effective procedure for patients

  18. N-butyl Cyanoacrylate Glue Embolization of Arterial Networks to Facilitate Hepatic Arterial Skeletonization before Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Samuelson, Shaun D.; Louie, John D.; Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-06-15

    Purpose. Avoidance of nontarget microsphere deposition via hepatoenteric anastomoses is essential to the safety of yttrium-90 radioembolization (RE). The hepatic hilar arterial network may remain partially patent after coil embolization of major arteries, resulting in persistent risk. We retrospectively reviewed cases where n-butyl cyanoacrylate (n-BCA) glue embolization was used to facilitate endovascular hepatic arterial skeletonization before RE. Methods. A total of 543 RE procedures performed between June 2004 and March 2012 were reviewed, and 10 were identified where n-BCA was used to embolize hepatoenteric anastomoses. Arterial anatomy, prior coil embolization, and technical details were recorded. Outcomes were reviewed to identify subsequent complications of n-BCA embolization or nontarget RE. Results. The rate of complete technical success was 80 % and partial success 20 %, with one nontarget embolization complication resulting in a minor change in treatment plan. No evidence of gastrointestinal or biliary ischemia or infarction was identified, and no microsphere-related gastroduodenal ulcerations or other evidence of nontarget RE were seen. Median volume of n-BCA used was <0.1 ml. Conclusion. n-BCA glue embolization is useful to eliminate hepatoenteric networks that may result in nontarget RE, especially in those that persist after coil embolization of major vessels such as the gastroduodenal and right gastric arteries.

  19. Angiographic manifestation and transcatheter arterial embolization of proper esophageal artery in hemoptysis

    International Nuclear Information System (INIS)

    Jiang Sen; Zhu Xiaohua; Sun Xiwen; Zhi Wenxiang; Jie Bing; You Zhengqian; Yu Dong; Peng Gang

    2008-01-01

    Objective: To investigate the angiographic manifestation of the proper esophageal artery (PEA), the high risk factors for the presence of the anomalous PEA in hemoptysis and to evaluate the safety of transcatheter arterial embolization (TAE) of the PEA using gelatin sponge (GS). Methods: Selective esophageal arteriography was performed in forty-three patients with hemoptysis, including 15 cases of pulmonary tuberculosis, 18 cases of bronchiectasis, 7 cases of posttuberculous bronchiectasis and three cases of lung cancer. One case experienced failure of bronchial arterial embolization. The angiographic manifestation of the PEAs was studied. The complications of the procedure and clinical results were observed in the patients who underwent TAE using GS. Results: Thirty-nine PEAs were catheterized selectively in 37 patients (86.0%). Eighteen anomalous PEAs (46.2%) were catheterized selectively in 17 patients (45.9%). The anomalous PEAs showed tortuosity, dilatation, hyperplasia, shunting with pulmonary artery and anastomosis with the bronchial artery. All lesions involved basal segment of inferior pulmonary lobar. Bronchiectasis was the most frequent disease for PEA abnormality. No complications occurred and satisfactory curative effect was achieved with TAE of the anomalous PEAs. Conclusions: It is necessary to perform selective proper esophageal arteriography when the lesion involves basal segment of inferior pulmonary lobar in hemoptysis. Supplemental TAE of the anomalous PEA using GS is safe and valuable in the management of hemoptysis. (authors)

  20. Optical Multidimensional Switching for Data Center Networks

    DEFF Research Database (Denmark)

    Kamchevska, Valerija

    2017-01-01

    . Software controlled switching using an on-chip integrated fiber switch is demonstrated and enabling of additional network functionalities such as multicast and optical grooming is experimentally confirmed. Altogether this work demonstrates the potential of optical switching technologies...... for the purpose of deploying optical switching within the network. First, the Hi-Ring data center architecture is proposed. It is based on optical multidimensional switching nodes that provide switching in hierarchically layered space, wavelength and time domain. The performance of the Hi-Ring architecture...... is evaluated experimentally and successful switching of both high capacity wavelength connections and time-shared subwavelengthconnections is demonstrated. Error-free performance is also achieved when transmitting 7 Tbit/s using multicore fiber, confirming the ability to scale the network. Moreover...

  1. Pinning Synchronization of Switched Complex Dynamical Networks

    Directory of Open Access Journals (Sweden)

    Liming Du

    2015-01-01

    Full Text Available Network topology and node dynamics play a key role in forming synchronization of complex networks. Unfortunately there is no effective synchronization criterion for pinning synchronization of complex dynamical networks with switching topology. In this paper, pinning synchronization of complex dynamical networks with switching topology is studied. Two basic problems are considered: one is pinning synchronization of switched complex networks under arbitrary switching; the other is pinning synchronization of switched complex networks by design of switching when synchronization cannot achieved by using any individual connection topology alone. For the two problems, common Lyapunov function method and single Lyapunov function method are used respectively, some global synchronization criteria are proposed and the designed switching law is given. Finally, simulation results verify the validity of the results.

  2. Synchronization in complex networks with switching topology

    International Nuclear Information System (INIS)

    Wang, Lei; Wang, Qing-guo

    2011-01-01

    This Letter investigates synchronization issues of complex dynamical networks with switching topology. By constructing a common Lyapunov function, we show that local and global synchronization for a linearly coupled network with switching topology can be evaluated by the time average of second smallest eigenvalues corresponding to the Laplacians of switching topology. This result is quite powerful and can be further used to explore various switching cases for complex dynamical networks. Numerical simulations illustrate the effectiveness of the obtained results in the end. -- Highlights: → Synchronization of complex networks with switching topology is investigated. → A common Lyapunov function is established for synchronization of switching network. → The common Lyapunov function is not necessary to monotonically decrease with time. → Synchronization is determined by the second smallest eigenvalue of its Laplacian. → Synchronization criterion can be used to investigate various switching cases.

  3. Energy storage, compression, and switching. Vol. 2

    International Nuclear Information System (INIS)

    Nardi, V.; Bostick, W.H.; Sahlin, H.

    1983-01-01

    This book is a compilation of papers presented at the Second International Conference on Energy Storage, Compression, and Switching, which was held in order to assemble active researchers with a major interest in plasma physics, electron beams, electric and magnetic energy storage systems, high voltage and high current switches, free-electron lasers, and pellet implosion plasma focus. Topics covered include: Slow systems: 50-60 Hz machinery, homopolar generators, slow capacitors, inductors, and solid state switches; Intermediate systems: fast capacitor banks; superconducting storage and switching; gas, vacuum, and dielectric switching; nonlinear (magnetic) switching; imploding liners capacitors; explosive generators; and fuses; and Fast systems: Marx, Blumlein, oil, water, and pressurized water dielectrics; switches; magnetic insulation; electron beams; and plasmas

  4. Near-infrared vascular imaging in peripheral venous and arterial access

    OpenAIRE

    Cuper, N.J.

    2012-01-01

    Venous and arterial access are among the most widespread medical procedures performed in children. Especially in young children venous and arterial access can be problematic due to tiny blood vessels that are difficult to localize beneath a layer of baby fat. This thesis describes the development and clinical evaluation of the VascuLuminator, a guidance tool for peripheral venous and arterial access by visualizing blood vessels underneath the skin with near-infrared light. In a third to a fif...

  5. Embolization of Life-Threatening Arterial Rupture in Patients with Vascular Ehlers–Danlos Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Takuya, E-mail: okabone@gmail.com [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Frank, Michael, E-mail: michael.frank@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Rare Vascular Diseases Reference Center (France); Pellerin, Olivier, E-mail: olivier@pellerin.as; Primio, Massimiliano Di, E-mail: massimiliano.di.primio@gmail.com; Angelopoulos, Georgios, E-mail: giorginos78@msn.com [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Boughenou, Marie-Fazia, E-mail: marie-fazia.boughenou@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Anesthesia and Surgical Intensive Care Unit (France); Pagny, Jean-Yves, E-mail: jean-yves.pagny@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Messas, Emmanuel, E-mail: emmanuel.messas@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Rare Vascular Diseases Reference Center (France); Sapoval, Marc, E-mail: marc.sapoval2@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France)

    2013-05-09

    PurposeTo evaluate the safety and efficacy of transarterial embolization of life-threatening arterial rupture in patients with vascular Ehlers–Danlos syndrome (vEDS) in a single tertiary referral center.MethodsWe retrospectively analyzed transarterial embolization for vEDS performed at our institution from 2000 to 2012. The indication of embolization was spontaneous arterial rupture or pseudoaneurysm with acute bleeding. All interventions used a percutaneous approach through a 5F or less introducer sheath. Embolic agents were microcoils and glue in 3 procedures, glue alone in 2, and microcoils alone in 2.ResultsFive consecutive vEDS patients were treated by 7 embolization procedures (4 women, mean age 29.8 years). All procedures were successfully performed. Two patients required a second procedure for newly arterial lesions at a different site from the first procedure. Four of the five patients were still alive after a mean follow-up of 19.4 (range 1–74.7) months. One patient died of multiple organ failure 2 days after procedure. Minor procedural complications were observed in 3 procedures (43 %), all directly managed during the same session. Remote arterial lesions occurred after 3 procedures (43 %); one underwent a second embolization, and the other 2 were observed conservatively. Puncture site complication was observed in only one procedure (14 %).ConclusionEmbolization for vEDS is a safe and effective method to manage life-threatening arterial rupture.

  6. Embolization of Life-Threatening Arterial Rupture in Patients with Vascular Ehlers–Danlos Syndrome

    International Nuclear Information System (INIS)

    Okada, Takuya; Frank, Michael; Pellerin, Olivier; Primio, Massimiliano Di; Angelopoulos, Georgios; Boughenou, Marie-Fazia; Pagny, Jean-Yves; Messas, Emmanuel; Sapoval, Marc

    2014-01-01

    PurposeTo evaluate the safety and efficacy of transarterial embolization of life-threatening arterial rupture in patients with vascular Ehlers–Danlos syndrome (vEDS) in a single tertiary referral center.MethodsWe retrospectively analyzed transarterial embolization for vEDS performed at our institution from 2000 to 2012. The indication of embolization was spontaneous arterial rupture or pseudoaneurysm with acute bleeding. All interventions used a percutaneous approach through a 5F or less introducer sheath. Embolic agents were microcoils and glue in 3 procedures, glue alone in 2, and microcoils alone in 2.ResultsFive consecutive vEDS patients were treated by 7 embolization procedures (4 women, mean age 29.8 years). All procedures were successfully performed. Two patients required a second procedure for newly arterial lesions at a different site from the first procedure. Four of the five patients were still alive after a mean follow-up of 19.4 (range 1–74.7) months. One patient died of multiple organ failure 2 days after procedure. Minor procedural complications were observed in 3 procedures (43 %), all directly managed during the same session. Remote arterial lesions occurred after 3 procedures (43 %); one underwent a second embolization, and the other 2 were observed conservatively. Puncture site complication was observed in only one procedure (14 %).ConclusionEmbolization for vEDS is a safe and effective method to manage life-threatening arterial rupture

  7. Arterial disease after radiotherapy

    International Nuclear Information System (INIS)

    Bigot, J.M.; Mathieu, D.; Reizine, D.

    1983-01-01

    Disease of the large arterial vessels is a relatively unknown complication of radiotherapy. However, it should be considered in the same manner as the other complications of irradiation when a tumour recurrence is suspected. The experimental studies of Kirkpatrick and Konings, demonstrating the synergy between irradiation and hypercholesterolemia in the precocity and gravity of vascular complications are recalled. The different localisations reported in the litterature are discussed: coronary, pulmonary, thoracic aorta, supra aortic, renal, digestive and ilio-femoral arteries. Finally, the difficulty of diagnosis of post-radiotherapy without clinical, radiological or anatomopathological confirmation, is underlined [fr

  8. Renal artery stenosis.

    Science.gov (United States)

    Tafur-Soto, Jose David; White, Christopher J

    2015-02-01

    Atherosclerotic renal artery stenosis (RAS) is the single largest cause of secondary hypertension; it is associated with progressive renal insufficiency and causes cardiovascular complications such as refractory heart failure and flash pulmonary edema. Medical therapy, including risk factor modification, renin-angiotensin-aldosterone system antagonists, lipid-lowering agents, and antiplatelet therapy, is advised in all patients. Patients with uncontrolled renovascular hypertension despite optimal medical therapy, ischemic nephropathy, and cardiac destabilization syndromes who have severe RAS are likely to benefit from renal artery revascularization. Screening for RAS can be done with Doppler ultrasonography, CT angiography, and magnetic resonance angiography. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Systemic Arterial-to-Pulmonary Artery Shunt Utilization

    African Journals Online (AJOL)

    multiruka1

    In certain circumstances, such as cyanotic neonates with tetralogy of Fallot (4) or cyanotic patients with. Tetralogy of Fallot and hypoplastic pulmonary arteries. (5), better outcomes are obtained if definitive surgery. (total correction or palliation) is preceded by creation of a systemic arterial-to-pulmonary artery shunt (SAPAS).

  10. Endovascular treatment of splenic artery aneurysms

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Dizonno, Massimiliano; Fugazzola, Carlo; Castelli, Patrizio

    2005-01-01

    Purpose. To assess the feasibility and effectiveness of endovascular treatment of splenic artery aneurysm (SAAs). Materials and methods. Between May 2000 and June 2003 we treated 11 true SAAs in 9 patients (7 females and 2 males; mean age 58 years), 8 saccular and 3 fusiform, 4 located at the middle tract of the splenic artery, 5 at the distal tract and 2 intra-parenchymal. The diagnosis was performed with colour-Doppler ultrasound and/or CT-angiography; 7 patients were symptomless, 1 had left hypochondriac pain, and 1 had acute abdomen caused by a ruptured SAA. Four SAAs were treated by micro coil embolisation of the aneurysmal sac with preservation of splenic artery patency; in 2 cases this was associated with transcatheter injection of N-butyl-2-cyanoacrylate. Four cases were treated by endovascular ligature, with sectoral spleen ischaemia. One ruptured SAA received emergency treatment with splenic artery cyanoacrylate embolisation. Two intra-parenchymal SAAs were excluded, one by cyanoacrylate embolisation of the afferent artery and the other by transcatheter thrombin injection in the aneurysmal sac. Results. Technical success was observed in all cases (in 10/11 at the end of the procedure; in 1/11 at CT performed 3 days after the procedure). The follow-up (mean 18 months; range 6-36) was performed by colour-Doppler ultrasound and/or CT-angiography 3, 6 and 12 months after the procedure and subsequently once a year; the complete exclusion of the aneurysms was confirmed in 11/11 cases. The complications were: 4 cases of mild pleuritis; fever and left hypochondriac pain 1 day after the procedure (in the same 4 patients and in one other case); 5 cases of sectorial spleen ischaemia and 1 case of diffuse spleen infarction with partial revascularization by collateral vessels. No alteration of the levels of pancreatic enzymes was found; a transitory increase in platelet count occurred only in the patient with diffuse spleen infarction. Conclusions. Using different

  11. Experimental verification of rank 1 chaos in switch-controlled Chua circuit.

    Science.gov (United States)

    Oksasoglu, Ali; Ozoguz, Serdar; Demirkol, Ahmet S; Akgul, Tayfun; Wang, Qiudong

    2009-03-01

    In this paper, we provide the first experimental proof for the existence of rank 1 chaos in the switch-controlled Chua circuit by following a step-by-step procedure given by the theory of rank 1 maps. At the center of this procedure is a periodically kicked limit cycle obtained from the unforced system. Then, this limit cycle is subjected to periodic kicks by adding externally controlled switches to the original circuit. Both the smooth nonlinearity and the piecewise linear cases are considered in this experimental investigation. Experimental results are found to be in concordance with the conclusions of the theory.

  12. Transuterinal artery interventional therapy for fallopian tubal pregnancy

    International Nuclear Information System (INIS)

    Jiang Zaibo; Shan Hong; Guan Shouhai; Ma Zhuang; Huang Mingsheng; Li Zhengran; Zhu Kangshun; Chen Hanwei; Xiao Jibo; Mu Yongsheng

    2001-01-01

    Objective: To study the methods and clinical effect of transuterinal artery interventional therapy of fallopian tubal pregnancy. Methods: The authors cured 34 cases of fallopian tubal pregnancy by interventional methods. In the procedure, 4.1 - 5.0 F catheters were used for performing super selective angiography in uterine artery and then infusing Methotrexate 50-100 mg. Finally gelfoam particles or stripes were used to embolise uterine artery. Before and after the procedure, patients showed changes of clinical symptom, physical signs. Value of urine β-hCG and size of pregnancy cyst were studied. Results: 31 cases were succeeded. The successful rate was 91%. 37 fallopian tubal arteries were displayed in 40 uterine arterial angiographies. The stain of ovary was shown done in 21 cases, the appearance rate was 68%. The stain of pregnant cyst was in six cases, the appearance rate was 18%. Conclusion: It is safe and efficient in performing transuterine artery chemo-embolization for therapy of fallopian tubal pregnancy. It could prevent and control fatal bleeding induced by pregnancy cyst rupture

  13. Intractable epistaxis: which arteries are responsible? An angiographic study.

    Science.gov (United States)

    de Bonnecaze, Guillaume; Gallois, Y; Chaynes, P; Bonneville, F; Dupret-Bories, A; Chantalat, E; Serrano, E

    2017-11-01

    Epistaxis constitutes a significant proportion of the Otolaryngologist's emergency workload. Optimal management differs in relation to the anatomic origin of the bleeding. The outcome of our study was to determine which artery(ies) could be considered as the cause of severe bleeding in the context of severe epistaxis. Fifty-five procedures of embolization preceded by angiography were reviewed. Medical records of interventionally treated patients were analysed for demographics, medical history, risk factors and clinical data. Angiographic findings were also assessed for active contrast extravasation (blush), vascular abnormality and embolised artery. Previous angiography showed an active contrast extravasation in only 20 procedures. The most common bleeding source was the sphenopalatine artery (SPA) followed by anterior ethmoïdal artery (AEA) and facial artery. Majority of multiple or bilateral extravasations occured in patients with systemic factors. A better understanding of the potential bleeding source might help and limit the risk of treatment failures. Our study confirms that the SPA is the most common cause of severe bleeding. We also emphasise the role of the AEA not only in traumatic context. Others arteries are rarely involved except in patients with comorbidities or frequent recurrences.

  14. Software development for a switch-based data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Booth, A. (Superconducting Super Collider Lab., Dallas, TX (United States)); Black, D.; Walsh, D. (Fermi National Accelerator Lab., Batavia, IL (United States))

    1991-12-01

    We report on the software aspects of the development of a switch-based data acquisition system at Fermilab. This paper describes how, with the goal of providing an integrated systems engineering'' environment, several powerful software tools were put in place to facilitate extensive exploration of all aspects of the design. These tools include a simulation package, graphics package and an Expert System shell which have been integrated to provide an environment which encourages the close interaction of hardware and software engineers. This paper includes a description of the simulation, user interface, embedded software, remote procedure calls, and diagnostic software which together have enabled us to provide real-time control and monitoring of a working prototype switch-based data acquisition (DAQ) system.

  15. Pharmacological modulation of arterial stiffness.

    LENUS (Irish Health Repository)

    Boutouyrie, Pierre

    2011-09-10

    Arterial stiffness has emerged as an important marker of cardiovascular risk in various populations and reflects the cumulative effect of cardiovascular risk factors on large arteries, which in turn is modulated by genetic background. Arterial stiffness is determined by the composition of the arterial wall and the arrangement of these components, and can be studied in humans non-invasively. Age and distending pressure are two major factors influencing large artery stiffness. Change in arterial stiffness with drugs is an important endpoint in clinical trials, although evidence for arterial stiffness as a therapeutic target still needs to be confirmed. Drugs that independently affect arterial stiffness include antihypertensive drugs, mostly blockers of the renin-angiotensin-aldosterone system, hormone replacement therapy and some antidiabetic drugs such as glitazones. While the quest continues for \\'de-stiffening drugs\\

  16. Pulmonary arterial hypertension : an update

    NARCIS (Netherlands)

    Hoendermis, E. S.

    2011-01-01

    Pulmonary arterial hypertension (PAH), defined as group 1 of the World Heart Organisation (WHO) classification of pulmonary hypertension, is an uncommon disorder of the pulmonary vascular system. It is characterised by an increased pulmonary artery pressure, increased pulmonary vascular resistance

  17. Are intravenous injections of contrast media really less nephrotoxic than intra-arterial injections?

    Energy Technology Data Exchange (ETDEWEB)

    Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Trelleborg (Sweden); Almen, Torsten [Skaane University Hospital, Department of Clinical Sciences/Medical Radiology, University of Lund, Malmoe (Sweden); Jacobsson, Bo [University of Gothenburg and the Sahlgrenska Academy, Department of Diagnostic Radiology, The Queen Silvia Children' s Hospital, Goeteborg (Sweden); Aspelin, Peter [Karolinska Institute and University Hospital, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm (Sweden)

    2012-06-15

    We oppose the opinion that the intra-arterial administration of iodine-based contrast media (CM) appears to pose a greater risk of contrast medium-induced nephropathy (CIN) than intravenous administration since (1) in intra-arterial coronary procedures and most other intra-arterial angiographic examinations, CM injections are also intravenous relative to the kidneys, (2) there is a lack of comparative trials studying the risk of CIN between intra-arterial and intravenous procedures with matched risk factors and CM doses, (3) a bias selection of patients with fewer risk factors may explain the seemingly lower rate of CIN after CT in comparison with coronary interventions, (4) the rate of CIN following intra-arterial coronary procedures may also be exaggerated owing to other causes of acute kidney failure, such as haemodynamic instability and microembolisation, (5) roughly the same gram-iodine/GFR ratio ({approx}1:1) as a limit of relatively safe CM doses has preliminarily been found for both intravenous CT and intra-arterial coronary procedures and (6) the substantially higher injected intravenous CM dose rate during CT relative to an intra-arterial coronary procedure might actually pose a higher risk of CIN following CT. Key Points circle Most intra-arterial injections of contrast media are intravenous relative to the kidneys. circle No evidence that intravenous CM injections should be less nephrotoxic than intra-arterial. circle Considerably higher dose rates of CM are used for CT relative to intra-arterial procedures. circle Higher dose rates may pose higher nephrotoxic risk for intravenous based CT studies. (orig.)

  18. Liver cirrhosis and arterial hypertension

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik; Møller, Søren

    2006-01-01

    blood pressure. This review considers the alterations in systemic hemodynamics in patients with cirrhosis in relation to essential hypertension and arterial hypertension of the renal origin. Subjects with arterial hypertension (essential, secondary) may become normotensive during the development...... of cirrhosis, and arterial hypertension is rarely manifested in patients with cirrhosis, even in cases with renovascular disease and high circulating renin activity. There is much dispute as to the understanding of homoeostatic regulation in cirrhotic patients with manifest arterial hypertension. This most...

  19. Subintimal stent placement in patients with long segment occlusion of the iliac artery

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ho Jung; Kim, Young Hwan; Kim, Si Hyung; Ko, Sung Min; Choi, Jin Soo; Lee, Hyun Jin; Kim, Hyung Tae; Jo, Won Hyun [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of)

    2008-01-15

    We evaluated the technical feasibility and clinical efficacy of subintimal stent placement for long segment occlusion of the iliac artery. From March 2003 to February 2007, subintimal stent placement for long segment occlusion of the iliac artery of 24 limbs in 22 patients was analyzed retrospectively. Endovascular access was performed via the ipsilateral femoral artery in 7 cases, via the contralateral femoral artery in 6 cases, via both femoral arteries in 10 cases and via the brachial artery in one case. The SAFARI (subintimal arterial flossing with antegrade-retrograde intervention) technique using a microcatheter was performed to recannalize iliac artery occlusion in three cases. Medical records were reviewed for the collection of follow-up data. The stent patency rate was analyzed by use of the Kaplan-Meier method. Subintimal stent placement was technically successful in 23 of 24 procedures (95.8%). The mean ankle-brachial index (ABI) increased form 0.26 to 0.82. The Fontaine classification was improved after stent placement in all patients. Major complications occurred in four procedures: three distal embolizations and one arterial rupture. All of the complications were successfully treated by endovascular intervention. The primary stent patency rates at 6-months, 1-, 2-and 3-years were 95%, 88%, 88% and 88%, respectively. Subintimal stent placement is a safe and effective treatment for long segment occlusion of the iliac artery.

  20. Near-infrared vascular imaging in peripheral venous and arterial access

    NARCIS (Netherlands)

    Cuper, N.J.

    2012-01-01

    Venous and arterial access are among the most widespread medical procedures performed in children. Especially in young children venous and arterial access can be problematic due to tiny blood vessels that are difficult to localize beneath a layer of baby fat. This thesis describes the development

  1. Electrical neuromodulation for disabling angina pectoris related to isolated stenoses of small epicardial coronary arteries

    NARCIS (Netherlands)

    Jessurun, GAJ; Hautvast, RWM; DeJongste, MJL; Meyler, WJ; van Boven, AJ; Crijns, HJGM

    Patients with symptomatic small vessel coronary artery disease may be inadequate candidates for revascularization procedures. They may suffer from refractory angina, which does not respond to maximal anti-anginal drug therapy. In addition to patients with end stage coronary artery disease and

  2. Dual (type IV) left anterior descending artery | Baskan | SA Journal of ...

    African Journals Online (AJOL)

    ... LAD originating from the right coronary artery (RCA). Dual LAD is a benign coronary artery anomaly, but should be recognised especially before interventional procedures. With the increasing use of multidedector computed tomography (MDCT), it is essential for radiologists to be aware of this entity and the cross-sectional ...

  3. Interventional radiology. Vol. 1. Endovascular reconstruction of the pelvic arteries in case of peripheral arterial occlusion

    International Nuclear Information System (INIS)

    Berger, H.; Pickel, P.; Weiss, W.

    2003-01-01

    Catheters and stents are effective techniques for treating arterial occlusion and make high demands on the medical experts, which must be highly competent and able to take quick decisions. This CD-ROM offers multimedia information including video and animation to explain the correct use of these methods. Exemplary cases are presented step by step. Subjects: Diagnosis; Surgical materials; Description of the surgical procedure; Documentation of results; Practical hints; Bibliography; Current studies. (orig.)

  4. Close to Transplant Renal Artery Stenosis and Percutaneous Transluminal Treatment

    Directory of Open Access Journals (Sweden)

    Leonardou Polytimi

    2011-01-01

    Full Text Available Purpose. To evaluate the efficacy of percutaneous transluminal angioplasty (PTA in the management of arterial stenosis located close to the allograft anastomosis (close-TRAS. Materials and Methods. 31 patients with renal transplants were admitted to our institution because of persistent hypertension and impairment of transplant renal function and underwent angiography for vascular investigation. 27 were diagnosed suffering from transplant renal artery stenosis (TRAS, whereas 4 had severe iliac artery stenosis proximal to the transplant anastomosis (Prox-TRAS. 3 cases of TRAS coexisted with segmental renal arterial stenosis, whereas 3 other cases of TRAS were caused by kinking and focal stenosis in the middle of the transplanted renal artery. Results. Angioplasty and stenting were successfully applied to all patients with iliac artery stenosis as well as to those with TRAS and segmental artery stenosis. Two of three patients with kinking were well treated with angioplasty and stenting, whereas one treated only with angioplasty necessitated surgery. No major procedure-related complications appeared, and the result was decrease of the serum creatinine level and of the blood pressure. Conclusions. PTA is the appropriate initial treatment of TRAS and close-TRAS, with low morbidity and mortality rates, achieving improvement of graft function and amelioration of hypertension.

  5. Peripheral Artery Disease

    Science.gov (United States)

    ... pressure High blood cholesterol Coronary heart disease Stroke Metabolic syndrome Screening and Prevention Taking action to control your risk factors can help prevent or delay peripheral artery disease (P.A.D.) and its complications. Know your family history of health problems related to P.A. ...

  6. Civilian popliteal artery injuries

    African Journals Online (AJOL)

    with reversed vein grafting in 68 patients, primary anastomosis in 33, prosthetic graft insertion in 11, ... patients underwent delayed amputation, giving an overall amputation rate of 37.5%. .... injury, level of arterial injury and type of repair had no significant ... patients, graft occlusion, and diseased crural vessels with poor run-.

  7. Pulmonary Arterial Hypertension

    Science.gov (United States)

    ... heart). This type of pulmonary hypertension was called “secondary pulmonary hypertension” but is now referred to as PH, because the cause is known to be from lung disease, heart disease, or chronic thromboemboli (blood clots). Pulmonary Arterial Hypertension (PAH) used to be ...

  8. Localized arterial occlusion following irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, S; Hasue, M [Japan Red Cross Medical Center, Tokyo; Fujiwara, M

    1982-04-01

    Occlusion of the major artery (the iliac artery in 2 cases and subclavicular artery in one) was reported, which occurred in association with bone necrosis 5 - 21 years after postoperative radiotherapy for malignant tumors (uterine cancer in 2 cases and mammary cancer in one).

  9. Intra-arterial vasodilators to prevent radial artery spasm: a systematic review and pooled analysis of clinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Kwok, Chun Shing, E-mail: shingkwok@doctors.org.uk [Keele Cardiovascular Research Group, Keele University, Stoke-on-Trent (United Kingdom); Rashid, Muhammad [St. Helens & Knowsley Teaching Hospital (NHS) Trust, Whiston Hospital, Prescot (United Kingdom); Fraser, Doug [Manchester Heart Centre, Manchester Royal Infirmary (United Kingdom); Nolan, James [University Hospital of North Midlands, Stoke-on-Trent (United Kingdom); Mamas, Mamas [Keele Cardiovascular Research Group, Keele University, Stoke-on-Trent (United Kingdom); Farr Institute, Institute of Population Health, University of Manchester, Manchester (United Kingdom)

    2015-12-15

    Objectives: The aim of this study is to review the available literature on the efficacy and safety of agents used for prevention of RAS. Background: Different vasodilator agents have been used to prevent radial artery spasm (RAS) in patients undergoing transradial cardiac catheterization. Methods: We included studies that evaluated any intra-arterial drug administered in the setting cardiac catheterization that was undertaken through the transradial access site (TRA). We also compared studies for secondary outcomes of major bleeding, procedure time, and procedure failure rate in setting of RAS prevention, patent hemostasis and radial artery occlusion. Results: 22 clinical studies met the inclusion criteria. For placebo, RAS rate was 12% (4 studies, 638 participants), which was similar to 2.5 mg of verapamil 12% (3 studies, 768 participants) but greater than 5 mg of verapamil (4%, 2 studies, 497 participants). For nicorandil, there was a much higher RAS rate compared to placebo (16%, 3 studies, 447 participants). The lowest rates of RAS was found for nitroglycerin at both 100 μg (4%) and 200 μg (2%) doses, isosorbide mononitrate (4%) and nicardipine (3%). We found no information regarding the procedure failure rates, patent hemostasis, and radial artery occlusion in these studies. Conclusions: In this largest and up-to-date review on intra-arterial vasodilators use to reduce RAS, we have found that the verapamil at a dose of 5 mg or verapamil in combination with nitroglycerine are the best combinations to reduce RAS. - Highlights: • Radial artery spasm (RAS) causes procedural failure in transradial catheterization. • RAS may complicate 10–15% procedures undertaken through the radial approach. • We reviewed the efficacy of vasodilators that have been used to minimize RAS. • The pooled RAS rate was lowest with 5 mg of verapamil (4%) compared to placebo (12%). • The best combination of drugs to minimize RAS is nitroglycerine and verapamil.

  10. Treatment of a symptomatic intrathoracic internal carotid artery

    Directory of Open Access Journals (Sweden)

    Christopher R. Brown

    2017-09-01

    Full Text Available Intrathoracic common carotid artery bifurcations are an anatomic anomaly with such rarity that only six cases have been reported to date. The true incidence of and preferred treatment options for a diseased intrathoracic common carotid artery bifurcation or internal carotid artery (ICA have not been clearly described. This case report describes a 72-year-old man who experienced a postoperative right hemispheric stoke after an aortic valve replacement, radiofrequency maze procedure, and left atrial appendage clip. Postoperative cerebrovascular evaluation revealed a severely diseased intrathoracic ICA that was treated by ligation of the diseased proximal ICA and transposition of the distal ICA to the disease-free external carotid artery. The patient provided written consent to present the history, data, and images in this manuscript.

  11. Enhancement of resistive switching properties in Al2O3 bilayer-based atomic switches: multilevel resistive switching

    Science.gov (United States)

    Vishwanath, Sujaya Kumar; Woo, Hyunsuk; Jeon, Sanghun

    2018-06-01

    Atomic switches are considered to be building blocks for future non-volatile data storage and internet of things. However, obtaining device structures capable of ultrahigh density data storage, high endurance, and long data retention, and more importantly, understanding the switching mechanisms are still a challenge for atomic switches. Here, we achieved improved resistive switching performance in a bilayer structure containing aluminum oxide, with an oxygen-deficient oxide as the top switching layer and stoichiometric oxide as the bottom switching layer, using atomic layer deposition. This bilayer device showed a high on/off ratio (105) with better endurance (∼2000 cycles) and longer data retention (104 s) than single-oxide layers. In addition, depending on the compliance current, the bilayer device could be operated in four different resistance states. Furthermore, the depth profiles of the hourglass-shaped conductive filament of the bilayer device was observed by conductive atomic force microscopy.

  12. Coronary Artery Bypass Grafting

    Science.gov (United States)

    ... lung bypass machine is used during this procedure. Robot-assisted technique. This type of procedure allows for ... driving after 3 to 8 weeks. Returning to work after 6 weeks is common unless your job ...

  13. Switch flap′ for full thickness upper eyelid reconstruction

    Directory of Open Access Journals (Sweden)

    Arvind Krishnamurthy

    2011-01-01

    Full Text Available Sebaceous gland carcinoma is an aggressive, uncommon, cutaneous malignancy. This tumour can arise anywhere in the body; approximately 75% of these tumours arise in the periocular region. The diagnosis and management of these malignancies often tend to get delayed because they are frequently mistaken for more common benign entities. Surgery has been and remains the primary treatment modality for sebaceous gland carcinomas. The resultant surgical defects following tumour excision generally tend to be full thickness and reconstructions of such defects pose significant challenges. These defects are conventionally reconstructed by the traditional bridging (eyelid sharing procedures, that is, the Cutler-Beard flap and its modifications. The ′Switch flap′ is an alternative eyelid sharing procedure; however, it is not very widely practiced. We recently used this procedure to reconstruct a large full-thickness upper eyelid defect with a satisfactory cosmetic and functional outcome.

  14. Iliac Artery Stent Placement Relieves Claudication in Patients with Iliac and Superficial Femoral Artery Lesions

    International Nuclear Information System (INIS)

    Ichihashi, Shigeo; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko

    2013-01-01

    Purpose. To evaluate the efficacy of iliac artery stent placement for relief of claudication in patients with both iliac and superficial femoral artery (SFA) lesions. Methods. Stent placement for only iliac artery occlusive disease was performed in 94 limbs (74 patients) with both iliac and SFA occlusive disease on the same limb. All procedures were performed because intermittent claudication did not improve after continuation of antiplatelet medication therapy and home-based exercise for 3 months. Rutherford classification was 2 in 20 limbs and 3 in 74 limbs. Patients with critical limb ischemia were excluded. Median duration of follow-up was 40 months. Primary patency rates of the iliac stent, clinical improvement rates, and risk factors for requiring additional SFA procedures were evaluated. Results. Primary patency rates of the iliac stent at 1, 3, 5, and 7 years were 97, 93, 79, and 79 %, respectively. The initial clinical improvement rate was 87 %. Continued clinical improvement rates at 1, 3, 5, and 7 years were 87, 81, 69, and 66 %, respectively. SFA Trans-Atlantic Inter-Society Consensus (TASC) II C/D lesion was a significant risk factor for requiring additional SFA procedures. Conclusion. Intermittent claudication was relieved by iliac stent placement in most patients with both iliac and SFA lesions. Thus, the indications for treatment of the SFA intended for claudicants should be evaluated after treatment of the iliac lesion.

  15. Cryopreserved Cadaveric Arterial Allograft for Arterial Reconstruction in Patients with Prosthetic Infection.

    Science.gov (United States)

    Lejay, Anne; Delay, Charline; Girsowicz, Elie; Chenesseau, Bettina; Bonnin, Emilie; Ghariani, Mohamed-Zied; Thaveau, Fabien; Georg, Yannick; Geny, Bernard; Chakfe, Nabil

    2017-11-01

    The aim of this study was to report outcomes of cryopreserved arterial allografts used as a vascular substitute in the setting of prosthetic material infection. A retrospective analysis of prospectively collected data was conducted including all consecutive interventions performed with cryopreserved arterial allografts used for vascular reconstruction in the setting of prosthetic material infection between January 2005 and December 2014. Five year outcomes included allograft related re-interventions, survival, primary patency, and limb salvage rates. Fifty-three procedures were performed using cryopreserved allografts for vascular prosthetic infection: 25 procedures (47%) were performed at aorto-iliac level (Group 1) and 28 procedures (53%) at peripheral level (Group 2). The mean follow-up was 52 months. Five year allograft related re-intervention was 55% in Group 1 (6 allograft ruptures and 5 allograft aneurysm degenerations) and 33% in Group 2 (2 allograft ruptures and 7 allograft aneurysm degenerations). Five year survival was 40% and 68%, primary patency was 89% and 59% and limb salvage was 100% and 89% for Group 1 and 2 respectively. Use of cryopreserved arterial allografts provides acceptable results but is tempered by suboptimal 5 year outcomes with high re-intervention rates. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Arrangement of permanent magnet and reed switches for control rod position indicator of SMART CEDM

    International Nuclear Information System (INIS)

    Yoo, J. Y.; Kim, J. I.; Kim, J. H.; Hur, H.; Jang, M. H.

    2001-01-01

    The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indication system and its actual implementation in the exiting nuclear power plants in Korea was performed first. The control rod position indicator having the high performance for SMART was developed on the basis of RSPT technology identified through the survey. The arrangement of permanent magnet and reed switches is the most important procedure in the design of control rod position indication. In this study, the characteristics of permanent magnet and reed switches are introduced and the calculation method for arrangement of permanent magnet and reed switch is presented

  17. Isolated unilateral absence of a pulmonary artery: a case report and review of the literature

    NARCIS (Netherlands)

    A.D.J. ten Harkel (Arend); N.A. Blom (Nico); J. Ottenkamp (Jaap)

    2002-01-01

    textabstractOBJECTIVE: The purpose of the present study was to determine the symptomatology, diagnostic procedures, and therapeutic strategies of patients with an isolated unilateral absence of a pulmonary artery (UAPA). BACKGROUND: Isolated UAPA is a rare anomaly. Some case

  18. Safety of non-ionic contrast media during renal artery stenting

    International Nuclear Information System (INIS)

    Ni Jun; Shen Weifeng; Zhang Ruiyan; Zhang Qi; Zhang Xian; Zheng Aifang

    2004-01-01

    Objective: To evaluate the safety of non-ionic contras media during interventional treatment of renal artery stenosis (RAS). Methods: Fifty four coronary artery disease patients associated with RAS (luminal narrowing > 50%) underwent renal artery stent implantation and percutaneous coronary intervention, only 10 of them with merely renoarterial stenosis undergone renal artery stent implantation. The successful rates of the procedure and complication together with the volumes of contrast media were recorded respectively. And the serum creatine before and 12 hours after the successful procedure were also measured. Results: Both rates of procedural success and complication were similar among the three groups. The serum creatine levels, 12 hours after the procedure, showed no difference in comparing with the baseline. Conclusion: Non-ionic contrast media (Iopamiro 370) could be safely used in patients with RAS. (authors)

  19. Refractory angina pectoris in end-stage coronary artery disease : Evolving therapeutic concepts

    NARCIS (Netherlands)

    Schoebel, FC; Frazier, OH; Jessurun, GAJ; DeJongste, MJL; Kadipasaoglu, KA; Jax, TW; Heintzen, MP; Cooley, DA; Strauer, BE; Leschke, M

    1997-01-01

    Refractory angina pectoris in coronary artery disease is defined as the persistence of severe anginal symptoms despite maximal conventional antianginal combination therapy. Further, the option to use an invasive revascularization procedure such as percutaneous coronary balloon angioplasty or

  20. Radiation-sensitive switching circuits

    Energy Technology Data Exchange (ETDEWEB)

    Moore, J.H.; Cockshott, C.P.

    1976-03-16

    A radiation-sensitive switching circuit has a light emitting diode which supplies light to a photo-transistor, the light being interrupted from time to time. When the photo-transistor is illuminated, current builds up and when this current reaches a predetermined value, a trigger circuit changes state. The peak output of the photo-transistor is measured and the trigger circuit is arranged to change state when the output of the device is a set proportion of the peak output, so as to allow for aging of the components. The circuit is designed to control the ignition system in an automobile engine.

  1. Radiation-sensitive switching circuits

    Energy Technology Data Exchange (ETDEWEB)

    Moore, J.H.; Cockshott, C.P.

    1976-03-16

    A radiation-sensitive switching circuit includes a light emitting diode which from time to time illuminates a photo-transistor, the photo-transistor serving when its output reaches a predetermined value to operate a trigger circuit. In order to allow for aging of the components, the current flow through the diode is increased when the output from the transistor falls below a known level. Conveniently, this is achieved by having a transistor in parallel with the diode, and turning the transistor off when the output from the phototransistor becomes too low. The circuit is designed to control the ignition system in an automobile engine.

  2. Evaluation of protocolized angiography in performing the interventional procedure for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Jiang Jianqiang; Shi Haibin; Liu Sheng; Yang Zhengqiang; Zhou Chungao; Zhou Weizhong

    2010-01-01

    Objective: To assess the clinical value of protocolized angiography,including the superior mesenteric artery (SMA), the celiac artery and the common hepatic artery angiography, in detecting the atypical tumor feeding arteries of hepatocellular carcinoma (HCC) during transarterial chemoembolization (TACE) procedure. Methods: The clinical data of all patients who received the initial TACE for HCC during the period of January 2005-December 2009 were collected and were retrospectively analyzed. Both the angiograms and procedure reports were reviewed. According to the angiography protocols used in interventional procedure the patients were divided into two groups. Group A included 526 patients who received the protocolized angiography, including the SMA, the celiac artery and the common hepatic artery, while Group B composed of 850 patients who underwent the routine angiography of the common hepatic artery. For all patients in both groups the atypical tumor feeding arteries were searched for when the tumor staining was incomplete. The anatomic variations of tumor feeding arteries were classified and were statistically analyzed. Results: The detection rate of tumor supply from the branches of SMA, left gastric artery, phrenic artery and celiac artery was 14.1%, 6.7%, 4.6% and 0.5% respectively in group A, while it was 8.9%, 3.3%, 2.6% and 0% respectively in group B. Significant difference in all above four detection rates existed between two groups (P 0.05). Conclusion: Compared with the conventional common hepatic arteriography during TACE, the diagnostic protocolized angiography, including the SMA, the celiac artery and the common hepatic artery, can markedly improve the detection rates of atypical tumor feeders of HCC, such as the accessory hepatic artery, which means that the tumor will be occluded more completely and be controlled more promptly. (authors)

  3. Morphologic expression of the left coronary artery in pigs. An approach in relation to human heart

    Directory of Open Access Journals (Sweden)

    Fabian Alejandro Gómez

    2014-04-01

    Full Text Available Introduction: In spite of its importance as an experimental model, the information on the left coronary artery in pigs is sparse. Objective: To determine the morphologic features of the left coronary artery in pigs. Methods: We evaluated 158 pig hearts. The left coronary artery was perfused with synthetic resin after their ostia had been catheterized. Diameters and courses of the vascular beds were measured with an electronic caliper (Mitutoyo(r. Results: The diameter of left coronary artery was 6.98 ± 1.56 mm and its length was 3.51±0.99 mm. It was found to end up by bifurcating itself into the anterior interventricular artery and the circumflex artery in 79% of the cases, and by trifurcating in 21% of the cases, with the presence of the diagonal artery. The anterior interventricular artery ended up at the apex in 79.7% of the cases, and the circumflex artery at the posterior aspect of the left ventricle in 64% of the case, this artery never reached the posterior interventricular sulcus. An anastomosis between the terminal branches of the anterior interventricular artery and the posterior interventricular artery was found in 7.6% of the specimens. The antero-superior branch of the anterior interventricular artery occurred in 89.9% of the hearts. A left marginal branch was observed in 87.9% of the cases with a diameter of 2.25±0.55 mm. Conclusion: Compared with humans, pigs have shorter left coronary artery trunks and branches; even the circumflex artery never reaches the posterior interventricular sulcus. Our findings are useful for the design of experimental hemodynamic and procedural models.

  4. Evaluation of variants in hepatic artery anatomy on conventional angiography in patients undergoing transarterial chemoembolization (tace): experience at siut

    International Nuclear Information System (INIS)

    Faiq, S.M.; Jesrani, A.; Jamal, M.; Lalwani, A.

    2017-01-01

    Objective: The purpose of this research is to evaluate common and uncommon variant of hepatic arterial anatomy that usually come across during Hepatic Angiographies. Study Design: Cross sectional study. Methods: This study included 50 patients having history of Hepatocellular Carcinoma from May to October 2015. Hepatic Angiography (Transarterial chemoembolization for management of Hepatoma and identification of classical and variant anatomy of hepatic artery) was evaluated in angiography unit. All procedures were performed on Digital Subtraction Angiography (DSA) machine (Toshiba KXO100 G). Selective DSA of the superior mesenteric artery and celiac trunk is performed initially to evaluate the frequency of normal and variant arterial anatomy and secondly to determine origin and course of tumor-feeding vessels. Evaluation of common and uncommon variants of hepatic arteries was done by using Michel’s classification as reference standard. Results: Age of the patient range from 40 – 80 years, 35 of whom were males. Fifty patients underwent angiographic procedure of viscera. Normal anatomy of hepatic artery was found in twenty eight (56%) cases. In six (12%) cases we found the replaced form of right hepatic artery (RHA) originating from visceral superior mesenteric artery. In five (10%) cases we found the replaced form of left hepatic artery (LHA) originating from left gastric artery (LGA), the combination of both these anomalies in one (2%) patient. Four (8%) cases had the left gastric artery giving rise to accessory left hepatic artery in conjunction with the common hepatic artery of celiac axis giving rise to typical right or left hepatic artery. In another four (8%) cases anatomic variation was noted in form of a dual arterial supply noted as common hepatic artery of celiac axis giving rise to typical left or right hepatic artery in conjunction with superior mesenteric artery giving rise to accessory right hepatic artery. In two (4%) cases superior mesenteric

  5. Applied anatomy of thyroid arteries for interventional embolization of Graves' disease

    International Nuclear Information System (INIS)

    Ding Zhongxiang; Zhao Wei; Hou Jialin; Xiang Shutian; Li Liyuan; Zou Zhirong; Li Xingguo; Song Dianping; Yuan Jianhua

    2007-01-01

    Objective: To explore the anatomy and imaging manifestations of thyroid arteries for improving the efficiency and lowering the complication in interventional embolization of Graves' disease. Methods: Thyroid arteries were investigated, including 16 adult cadavers (Cadaver group), 8 non-thyropathic patients (Normal group)and 17 Graves patients (Graves group). The inner diameters of the trunk and supplying branches of thyroid artery, the angles between the origination of branches and the beginning of the trunk, and the angles between the trunk of thyroid artery and carotid or subclavian artery were measured. In addition, data of the three groups were statistically analyzed. Results: Many non-thyroid arterial branches arose from thyroid artery, with no statistical difference in their indexes between Cadaver group and Normal group. The thyroid arteries showed much longer, obviously wider in diameter, and larger angles between the trunk of thyroid artery and carotid artery in Graves group than those of Cadaver group and Normal group; outcoming with significant statistical differences; and furthermore, with increase of interglandular branches and dangerous internal and external anastomoses. Conclusions: The specific thyroid arterial changes of Graves' disease are helpful for the interventional embolization. Non-thyroid branches and dangerous anastomoses should not be embolized as far as possible, for decreasing the complications of the interventional procedure for Graves' disease. (authors)

  6. Know-How on design of switching regulator

    International Nuclear Information System (INIS)

    1985-08-01

    This book introduces switching regulator from base to application, which deals with fundamentals of switching regulator such as the reason of boom about switching regulator, understanding simple circuit without electric transformer and decision of circuit type with input voltage and output voltage, configuration and characteristic of switching regulator, a concrete design of switching regulator, pulse width control circuit and protection circuit, concrete circuit examples of switching power and the point of switching regulator.

  7. Stateless multicast switching in software defined networks

    OpenAIRE

    Reed, Martin J.; Al-Naday, Mays; Thomos, Nikolaos; Trossen, Dirk; Petropoulos, George; Spirou, Spiros

    2016-01-01

    Multicast data delivery can significantly reduce traffic in operators' networks, but has been limited in deployment due to concerns such as the scalability of state management. This paper shows how multicast can be implemented in contemporary software defined networking (SDN) switches, with less state than existing unicast switching strategies, by utilising a Bloom Filter (BF) based switching technique. Furthermore, the proposed mechanism uses only proactive rule insertion, and thus, is not l...

  8. AN ANALYTICAL STUDY OF SWITCHING TRACTION MOTORS

    Directory of Open Access Journals (Sweden)

    V. M. Bezruchenko

    2010-03-01

    Full Text Available The analytical study of switching of the tractive engines of electric locomotives is conducted. It is found that the obtained curves of change of current of the sections commuted correspond to the theory of average rectilinear switching. By means of the proposed method it is possible on the stage of design of tractive engines to forecast the quality of switching and to correct it timely.

  9. Monitoring Mellanox Infiniband SX6036 switches

    CERN Document Server

    Agapiou, Marinos

    2017-01-01

    The SX6036 switches addressed by my project, are part of a fully non-blocking fat-tree cluster consisting of 72 servers and 6 Mellanox SX6036 Infiniband switches. My project is about retrieving the appropriate metrics from the Infiniband switch cluster, ingesting the data to Collectd and after my data are being transfered to CERN Database, they are being visualized via Grafana Dashboards.

  10. Optical switches based on surface plasmons

    International Nuclear Information System (INIS)

    Chen Cong; Wang Pei; Yuan Guanghui; Wang Xiaolei; Min Changjun; Deng Yan; Lu Yonghua; Ming Hai

    2008-01-01

    Great attention is being paid to surface plasmons (SPs) because of their potential applications in sensors, data storage and bio-photonics. Recently, more and more optical switches based on surface plasmon effects have been demonstrated either by simulation or experimentally. This article describes the principles, advantages and disadvantages of various types of optical switches based on SPs, in particular the all-optical switches. (authors)

  11. A new switched power linac structure

    International Nuclear Information System (INIS)

    Villa, F.

    1989-03-01

    A new pulse power structure has been described that utilizes an easily accessible rectilinear switch. The new structure is more ''forgiving'' (as far as risetime is concerned) than the radial line transformer, and contains fewer switching structures/unit length. The combination of the new structure with the switch proposed seems to offer interesting possibilities for a future linear collider. 13 refs., 6 figs., 2 tabs

  12. Switching induced oscillations in the logistic map

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Makisha P.S. [Department of Chemistry, Williams College, Williamstown, MA 01267 (United States); Peacock-Lopez, Enrique, E-mail: epeacock@williams.ed [Department of Chemistry, Williams College, Williamstown, MA 01267 (United States)

    2010-02-08

    In ecological modeling, seasonality can be represented as a switching between different environmental conditions. This switching strategy can be related to the so-called Parrondian games, where the alternation of two losing games yield a winning game. Hence we can consider two dynamics that, by themselves, yield undesirable behaviors, but when alternated yield a desirable oscillatory behavior. In this case, we also consider a noisy switching strategy and find that the desirable oscillatory behavior prevails.

  13. Ultrafast pulse generation in photoconductive switches

    DEFF Research Database (Denmark)

    Keil, Ulrich Dieter Felix; Dykaar, D. R.

    1996-01-01

    Carrier and field dynamics in photoconductive switches are investigated by electrooptic sampling and voltage-dependent reflectivity measurements. We show that the nonuniform field distribution due to the two-dimensional nature of coplanar photoconductive switches, in combination with the large di...... difference in the mobilities of holes and electrons, determine the pronounced polarity dependence. Our measurements indicate that the pulse generation mechanism is a rapid voltage breakdown across the photoconductive switch and not a local field breakdown...

  14. A magnetically switched kicker for proton extraction

    International Nuclear Information System (INIS)

    Dinkel, J.; Biggs, J.

    1989-03-01

    The application of magnetic current amplification and switching techniques to the generation of precise high current pulses for switching magnets is described. The square loop characteristic of Metglas tape wound cores at high excitation levels provides excellent switching characteristics for microsecond pulses. The rugged and passive nature of this type pulser makes it possible to locate the final stages of amplification at the load for maximum efficiency. 12 refs., 8 figs

  15. Complications of operative treatment of injuries of peripheral arteries.

    Science.gov (United States)

    Velinovic, M M; Davidovic, B L; Lotina, I S; Vranes, R M; Djukic, L P; Arsov, J V; Ristic, V M; Kocica, J M; Petrovic, L P

    2000-06-01

    In 1991 and 1992, a total of 97 patients with 106 peripherial arterial injuries underwent surgery at the Institute for Cardiovascular Diseases, Clinical Centre of Serbia. Civilian injuries accounted for 53 (54.6%) patients (94.3% males, age range: 16-63 yr, mean: 35.2), and 44 patients had war injuries (93.2% males, age range: 19-61 yr, mean: 34.8). The injuries affected the superfitial femoral artery in 31 (29.24%); the popliteal artery in 28 (26.41%); the brachial artery in 17 (16.04%); the posterior tibial artery in 6 (5.66%); the axillary artery in 5 (4.72%); the anterior tibial artery in 5 (4.72%); the tibioperoneal trunk in 4 (3. 77%); the common femoral artery in 4 (3.77%); the external iliac artery in 2 (1.89%); the profound femoral artery in 2 (1.89%); the radial artery in 1 (0.94%); and ulnar artery in 1 (0.94%).A total of 98 reconstructive procedures were used to treat these patients. Graft interposition carried out in 50 (51.02%); by pass in 25 (25. 51%); end-to-end anastomosis in 9 (9.18%); suture in 8 (8.16%); ligation in 4 (4.08%); and patch-angioplasty in 2 (2.04%). Primary reconstruction of injured arteries was performed in 72.2% and secondary repair in 27.8% cases. Infection developed in 51 (52.57%) patients, and it was significantly (P<0.05) more common in the war injuries (70.45%) and in secondary repairs (88.89%). The presence of associated lesions (69.56%) was also correlated with a greater rate of infection. Amputation was necessary in 21 (21.65%) of our patients, and was significantly (P<0.05) more often performed after secondary (44.44%) than primary operations (12.86%) and in the presence of associated injuries (32.61%).

  16. Bentall operation in a patient with an anomalous left circumflex artery: Case report and review

    Directory of Open Access Journals (Sweden)

    Ivo Gasparovic

    2017-10-01

    Full Text Available Anomalous origin of a left circumflex artery from the right coronary sinus represents a technical challenge in patients who require aortic valve/root procedures. This case report describes a patient who presented with bicuspid aortic valve, anomalous origin of the circumflex artery, severe aortic regurgitation, and aneurysm of the ascending aorta as well as aortic root that was safely managed following the Bentall procedure with the combined button technique.

  17. Bullet embolism of pulmonary artery: a case report

    Directory of Open Access Journals (Sweden)

    Mauricio Gustavo Ieiri Yamanari

    2014-04-01

    Full Text Available The authors report the case of a patient victim of gunshots, with a very rare complication: venous bullet embolism from the left external iliac vein to the lingular segment of the left pulmonary artery. Diagnosis is made with whole-body radiography or computed tomography. Digital angiography is reserved for supplementary diagnosis or to be used as a therapeutic procedure.

  18. Bullet embolism of pulmonary artery: a case report

    International Nuclear Information System (INIS)

    Yamanari, Mauricio Gustavo Ieiri; Mansur, Maria Clara Dias; Kay, Fernando Uliana; Silverio, Paulo Rogerio Barboza; Jayanthi, Shri Krishna; Funari, Marcelo Buarque de Gusmao

    2014-01-01

    The authors report the case of a patient victim of gunshots, with a very rare complication: venous bullet embolism from the left external iliac vein to the lingular segment of the left pulmonary artery. Diagnosis is made with whole-body radiography or computed tomography. Digital angiography is reserved for supplementary diagnosis or to be used as a therapeutic procedure. (author)

  19. Treatment of tubal pregnancy by uterine artery perfusion and embolization

    International Nuclear Information System (INIS)

    Ni Caifang; Zou Jianwei; Zhao Hui; Jin Yonghai; Zhu Xiaoli; Liu Yizhi; He Qi; Shen Zhongji

    2006-01-01

    Objective: To study the feasibility, safety, and efficacy of the treatment for tubal pregnancy by interventional technique of transuterine arterial catheterization perfusion and embolization. Methods: Using modified Seldinger technique, 42 cases of tubal pregnancy received super-selective angiography of uterine artery, followed by perfusion of 50-100 mg methotrexate (MTX) through the catheter and embolization of uterine artery with gelatin sponge. Before and after the procedure, changes of clinical symptoms, physical signs, value of β-hCG and size of pregnancy cyst of patients were studied. Concentrations of MTX in peripheral blood were studied at 0.5, 6, 12, 24, 36, 48 hours after the procedure. Results: 38 out of 42 cases were cured with successful rate of 90.5%(38/42). The average time of β-hCG decreasing to normal was 8.26 ± 2.04 days. The concentration of MTX in peripheral blood with 50 mg or 75 mg dosage could not be detected at 36 hours after the procedure but could be detected as 0.01 μmol/L at 48 hours after the procedure with a dosage of 100 mg. Conclusions: It is simple, safe and efficient in performing trans-uterine artery chemo-embolization for therapy of fallopian tubal pregnancy, especially for those who complicated with manipules bleeding and also as the first choice for prevention of high risk massive hemorrhage. (authors)

  20. 3D Image Fusion to Localise Intercostal Arteries During TEVAR

    Directory of Open Access Journals (Sweden)

    G. Koutouzi

    Full Text Available Purpose: Preservation of intercostal arteries during thoracic aortic procedures reduces the risk of post-operative paraparesis. The origins of the intercostal arteries are visible on pre-operative computed tomography angiography (CTA, but rarely on intra-operative angiography. The purpose of this report is to suggest an image fusion technique for intra-operative localisation of the intercostal arteries during thoracic endovascular repair (TEVAR. Technique: The ostia of the intercostal arteries are identified and manually marked with rings on the pre-operative CTA. The optimal distal landing site in the descending aorta is determined and marked, allowing enough length for an adequate seal and attachment without covering more intercostal arteries than necessary. After 3D/3D fusion of the pre-operative CTA with an intra-operative cone-beam CT (CBCT, the markings are overlaid on the live fluoroscopy screen for guidance. The accuracy of the overlay is confirmed with digital subtraction angiography (DSA and the overlay is adjusted when needed. Stent graft deployment is guided by the markings. The initial experience of this technique in seven patients is presented. Results: 3D image fusion was feasible in all cases. Follow-up CTA after 1 month revealed that all intercostal arteries planned for preservation, were patent. None of the patients developed signs of spinal cord ischaemia. Conclusion: 3D image fusion can be used to localise the intercostal arteries during TEVAR. This may preserve some intercostal arteries and reduce the risk of post-operative spinal cord ischaemia. Keywords: TEVAR, Intercostal artery, Spinal cord ischaemia, 3D image fusion, Image guidance, Cone-beam CT

  1. Variant anatomy of renal arteries in a Kenyan population.

    Science.gov (United States)

    Ogeng'o, Julius A; Masaki, Charles O; Sinkeet, Simeon R; Muthoka, Johnstone M; Murunga, Acleus K

    2010-01-01

    Variant anatomy of renal arteries is important in renal transplant, vascular reconstruction, and uroradiological procedures. The variations show ethnic and population differences. Data from Africans are scarce and altogether absent for Kenyans. To describe patterns of origin, trajectories and branching of renal arteries in a Kenyan population. Descriptive cross-sectional study conducted in the Department of Human Anatomy, University of Nairobi. Three hundred and fifty six kidneys from 178 cadavers and postmortem specimens were used in the study. Aorta, renal arteries and kidneys were exposed by dissection. Number, trajectories, level of branching, number of branches and point of entry into the kidney were recorded. Data was analyzed using SPSS version 16.0, and presented using macrographs, tables, and bar charts. Additional arteries occurred in 14.3% of the cases. In 82.4% of these, there was one additional artery. Fifty nine point five per cent of the double renal arteries were parallel and 7.1% crossed. Of the 305 single arteries, 76.4% showed hilar, 21.6% prehilar and 2% intraparenchymal branching. In the hilar branching, ladder type was present in 65% and fork type in 35%. Bifurcation and trifurcation were present in 59.6% and 33.1% respectively. Polar arteries were present in 16.9% cases. Over 14% of the Kenyan population may have additional renal arteries while more than 20% show early branching. Several trajectories and hilar branching patterns exist which renal transplant surgeons and radiologists should be aware of to avoid inadvertent vascular injury.

  2. Atomic battery with beam switching

    International Nuclear Information System (INIS)

    Edling, E.A.; McKenna, R.P.; Peterick, E.Th. Jr.; Trexler, F.D.

    1984-01-01

    An electric power generating apparatus that is powered primarily by the emission of electrically charged particles from radio-active materials enclosed in an evacuated vessel of glass or the like. An arrangement of reflecting electrodes causes a beam of particles to switch back and forth at a high frequency between two collecting electrodes that are connected to a resonating tuned primary circuit consisting of an inductor with resonating capacitor. The reflecting electrodes are energized in the proper phase relationship to the collecting electrodes to insure sustained oscillation by means of a secondary winding coupled inductively to the primary winding and connected to the reflecting electrodes. Power may be drawn from the circuit at a stepped down voltage from a power take-off winding that is coupled to the primary winding. The disclosure also describes a collecting electrode arrangement consisting of multiple spatially separated electrodes which together serve to capture a maximum of the available particle energy. A self-starting arrangement for start of oscillations is described. A specially adapted version of the invention utilizes two complementary beams of oppositely charged particles which are switched alternatingly between the collecting electrodes

  3. Atomic crystals resistive switching memory

    International Nuclear Information System (INIS)

    Liu Chunsen; Zhang David Wei; Zhou Peng

    2017-01-01

    Facing the growing data storage and computing demands, a high accessing speed memory with low power and non-volatile character is urgently needed. Resistive access random memory with 4F 2 cell size, switching in sub-nanosecond, cycling endurances of over 10 12 cycles, and information retention exceeding 10 years, is considered as promising next-generation non-volatile memory. However, the energy per bit is still too high to compete against static random access memory and dynamic random access memory. The sneak leakage path and metal film sheet resistance issues hinder the further scaling down. The variation of resistance between different devices and even various cycles in the same device, hold resistive access random memory back from commercialization. The emerging of atomic crystals, possessing fine interface without dangling bonds in low dimension, can provide atomic level solutions for the obsessional issues. Moreover, the unique properties of atomic crystals also enable new type resistive switching memories, which provide a brand-new direction for the resistive access random memory. (topical reviews)

  4. Heat switch technology for cryogenic thermal management

    Science.gov (United States)

    Shu, Q. S.; Demko, J. A.; E Fesmire, J.

    2017-12-01

    Systematic review is given of development of novel heat switches at cryogenic temperatures that alternatively provide high thermal connection or ideal thermal isolation to the cold mass. These cryogenic heat switches are widely applied in a variety of unique superconducting systems and critical space applications. The following types of heat switch devices are discussed: 1) magnetic levitation suspension, 2) shape memory alloys, 3) differential thermal expansion, 4) helium or hydrogen gap-gap, 5) superconducting, 6) piezoelectric, 7) cryogenic diode, 8) magneto-resistive, and 9) mechanical demountable connections. Advantages and limitations of different cryogenic heat switches are examined along with the outlook for future thermal management solutions in materials and cryogenic designs.

  5. Stochastic multistep polarization switching in ferroelectrics

    Science.gov (United States)

    Genenko, Y. A.; Khachaturyan, R.; Schultheiß, J.; Ossipov, A.; Daniels, J. E.; Koruza, J.

    2018-04-01

    Consecutive stochastic 90° polarization switching events, clearly resolved in recent experiments, are described by a nucleation and growth multistep model. It extends the classical Kolmogorov-Avrami-Ishibashi approach and includes possible consecutive 90°- and parallel 180° switching events. The model predicts the results of simultaneous time-resolved macroscopic measurements of polarization and strain, performed on a tetragonal Pb (Zr ,Ti ) O3 ceramic in a wide range of electric fields over a time domain of seven orders of magnitude. It allows the determination of the fractions of individual switching processes, their characteristic switching times, activation fields, and respective Avrami indices.

  6. The increased importance of sector switching

    DEFF Research Database (Denmark)

    Frederiksen, Anders; Hansen, Jesper Rosenberg

    2017-01-01

    Sector switching is an important phenomenon that casts light on public–private differences. Yet our knowledge about its prevalence and trends is limited. We study sector switching using unique Danish register-based employer–employee data covering more than 25 years. We find that sector switching...... constitutes 18.5% of all job-to-job mobility, and the trend is increasing both from public to private and from private to public. Sector switching is also generally increasing for middle managers, but for administrative professionals only the flows from private to public increase and for top managers only...... the flows from public to private increase....

  7. Wireless Nanoionic-Based Radio Frequency Switch

    Science.gov (United States)

    Nessel, James A. (Inventor); Miranda, Felix A (Inventor)

    2017-01-01

    A nanoionic switch connected to one or more rectenna modules is disclosed. The rectenna module is configured to receive a wireless signal and apply a first bias to change a state of the nanoionic switch from a first state to a second state. The rectenna module can receive a second wireless signal and apply a second bias to change the nanoionic switch from the second state back to the first state. The first bias is generally opposite of the first bias. The rectenna module accordingly permits operation of the nanoionic switch without onboard power.

  8. Low-Voltage Switched-Capacitor Circuits

    DEFF Research Database (Denmark)

    Bidari, E.; Keskin, M.; Maloberti, F.

    1999-01-01

    Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications.......Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications....

  9. Clocking Scheme for Switched-Capacitor Circuits

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    1998-01-01

    A novel clocking scheme for switched-capacitor (SC) circuits is presented. It can enhance the understanding of SC circuits and the errors caused by MOSFET (MOS) switches. Charge errors, and techniques to make SC circuits less sensitive to them are discussed.......A novel clocking scheme for switched-capacitor (SC) circuits is presented. It can enhance the understanding of SC circuits and the errors caused by MOSFET (MOS) switches. Charge errors, and techniques to make SC circuits less sensitive to them are discussed....

  10. Simplified design of switching power supplies

    CERN Document Server

    Lenk, John

    1995-01-01

    * Describes the operation of each circuit in detail * Examines a wide selection of external components that modify the IC package characteristics * Provides hands-on, essential information for designing a switching power supply Simplified Design of Switching Power Supplies is an all-inclusive, one-stop guide to switching power-supply design. Step-by-step instructions and diagrams render this book essential for the student and the experimenter, as well as the design professional. Simplified Design of Switching Power Supplies concentrates on the use of IC regulators. All popular forms of swit

  11. Demonstration of Ultra-Fast Switching in Nano metallic Resistive Switching Memory Devices

    International Nuclear Information System (INIS)

    Yang, Y.

    2016-01-01

    Interdependency of switching voltage and time creates a dilemma/obstacle for most resistive switching memories, which indicates low switching voltage and ultra-fast switching time cannot be simultaneously achieved. In this paper, an ultra-fast (sub-100 ns) yet low switching voltage resistive switching memory device (“nano metallic ReRAM”) was demonstrated. Experimental switching voltage is found independent of pulse width (intrinsic device property) when the pulse is long but shows abrupt time dependence (“cliff”) as pulse width approaches characteristic RC time of memory device (extrinsic device property). Both experiment and simulation show that the onset of cliff behavior is dependent on physical device size and parasitic resistance, which is expected to diminish as technology nodes shrink down. We believe this study provides solid evidence that nano metallic resistive switching memory can be reliably operated at low voltage and ultra-fast regime, thus beneficial to future memory technology.

  12. Iatrogenic femoral artery pseudoaneurysms - A review of current methods of diagnosis and treatment

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, F. [Department of Interventional Radiology, Royal Berkshire NHS Foundation Trust, Reading (United Kingdom)], E-mail: farhan@doctors.org.uk; Turner, S.A.; Torrie, P.; Gibson, M. [Department of Interventional Radiology, Royal Berkshire NHS Foundation Trust, Reading (United Kingdom)

    2008-12-15

    The common femoral artery is commonly used as arterial access for a wide range of radiological and cardiological procedures. Pseudoaneurysm formation is the most common arterial complication of femoral artery catheterization, and is diagnosed using colour Doppler ultrasound. Ultrasound-guided thrombin injection has replaced ultrasound-guided compression as the first-line treatment. The practicalities of thrombin injection (technique and types of thrombin available) and other treatment options are discussed. Awareness of pseudoaneurysm formation and the treatment options allows prompt diagnosis and successful treatment.

  13. Iatrogenic femoral artery pseudoaneurysms - A review of current methods of diagnosis and treatment

    International Nuclear Information System (INIS)

    Ahmad, F.; Turner, S.A.; Torrie, P.; Gibson, M.

    2008-01-01

    The common femoral artery is commonly used as arterial access for a wide range of radiological and cardiological procedures. Pseudoaneurysm formation is the most common arterial complication of femoral artery catheterization, and is diagnosed using colour Doppler ultrasound. Ultrasound-guided thrombin injection has replaced ultrasound-guided compression as the first-line treatment. The practicalities of thrombin injection (technique and types of thrombin available) and other treatment options are discussed. Awareness of pseudoaneurysm formation and the treatment options allows prompt diagnosis and successful treatment

  14. Caliber-Persistent Artery

    Directory of Open Access Journals (Sweden)

    Sabrina Araújo Pinho Costa

    2015-01-01

    Full Text Available Caliber-persistent artery (CPLA of the lip is a common vascular anomaly in which a main arterial branch extends to the surface of the mucous tissue with no reduction in its diameter. It usually manifests as pulsatile papule, is easily misdiagnosed, and is observed more frequently among older people, suggesting that its development may involve a degenerative process associated with aging; CPLA is also characterized by the loss of tone of the adjacent supporting connective tissue. Although the diagnosis is clinical, high-resolution Doppler ultrasound is a useful noninvasive tool for evaluating the lesion. This report describes the case of a 58-year-old male patient who complained of a lesion of the lower lip with bleeding and recurrent ulceration. The patient was successfully treated in our hospital after a diagnosis of CPLA and is currently undergoing a clinical outpatient follow-up with no complaints.

  15. Vertebral basilar artery dissections

    International Nuclear Information System (INIS)

    Zimmerman, R.A.; Bilaniuk, L.T.; Hackney, D.B.; Grossman, R.I.; Goldberg, H.I.; Atlas, S.W.

    1988-01-01

    Eleven patients (ten male, one female; range, 2-56 years) presented with posterior circulation ischemic symptoms and were evaluated with computed tomography (CT) (eta=11), arteriography (eta=11), and magnetic resonance (MR) imaging (eta=6). Angiography showed dissection of a vertebral artery (eta=8), a basilar artery (eta=1), or a combination of both (eta=2). On CT and/or MR images, infarctions were demonstrated in ten of 11 cases. Most frequently involved were the thalmus (eta=7), cerebellum (eta=6), occipital lobes (eta=4), and pons (eta=3). The site of infarction did not correlate with the side or site of angiographic abnormality. In six cases evaluated by all modalities, MR imaging showed more extensive and widespread infarction than did CT and also showed whether or not the infarcts were hemorrhagic. MR imaging was able to demonstrate the presence of intramural dissecting hematoma prior to angiography and to indicate whether or not flow was reconstituted on follow-up examination

  16. Ultrafast Switching Superjunction MOSFETs for Single Phase PFC Applications

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Petersen, Lars Press; Andersen, Michael A. E.

    2014-01-01

    This paper presents a guide on characterizing state-of-the-art silicon superjunction (SJ) devices in the 600V range for single phase power factor correction (PFC) applications. The characterization procedure is based on a minimally inductive double pulse tester (DPT) with a very low intrusive...... current measurement method, which enables reaching the switching speed limits of these devices. Due to the intrinsic low and non-linear capacitances in vertical SJ MOSFETs, special attention needs to be paid to the gate drive design to minimize oscillations and limit the maximum at turn off. This paper...

  17. Denervation of nerve terminals in renal arteries: one-year follow-up of interventional treatment of arterial hypertension.

    Science.gov (United States)

    Bartuś, Krzysztof; Sadowski, Jerzy; Kapelak, Bogusław; Litwinowicz, Radosław; Zajdel, Wojciech; Godlewski, Jacek; Bartuś, Magdalena; Zmudka, Krzysztof; Chrapusta, Anna; Konstanty-Kalandyk, Janusz; Węgrzyn, Piotr; Sobotka, Paul A

    2014-01-01

    Arterial hypertension is the most common cardiovascular system disease, affecting nearly one billion people worldwide. Despite the widespread use of antihypertensive medications, in some groups of patients an optimal blood pressure (BP) cannot be achieved. To assess BP reduction in patients with resistant hypertension after a catheter-based renal sympathetic denervation procedure and to report vascular and kidney safety in one-year follow-up. Twenty eight patients with diagnosed resistant hypertension (median age 52.02 years, range 42-72) underwent percutaneous catheter-based renal denervation of nerve terminals in renal arteries. Arterial angiography and procedure of ablation was performed by Symplicity catheters and generator provided by Ardian (currently Medtronic Inc., USA). Mean BP value before ablation was [mm Hg]: systolic 176.6, diastolic 100.28 and pulse pressure 73.4. After the procedure, reductions in the value of BP were reported [mm Hg]: systolic 154.8/152.54; diastolic 90.2/89.8, pulse pressure 64.66/62.73, respectively in nine-month and one-year follow-up. All results were statistically significant. No complications during one year observation were observed. Percutaneous renal artery ablation procedure effectively reduces systolic BP, diastolic BP, and pulse pressure. No vascular or renal complications in any of the patients were observed. The results of a Polish research group showed no significant differences compared to the results obtained in the international studies Symplicity I and Symplicity II.

  18. Popliteal artery entrapment syndrome

    International Nuclear Information System (INIS)

    Klooster, N.J.J.; Janevski, B.K.; Kitslaar, P.

    1988-01-01

    Two patients with unilateral popliteal artery entrapment syndrome (PAES) are reported. The importance of diligence in angiographic diagnosis and recognition of the so-called 'functional' PAES group as a separate entity are stressed. It is inferred from our material that a surgical approach for PAES is to be advocated since surgical release of the entrapment can lead to complete resolution of symptoms regardless of aetiology. (orig.) [de

  19. Diagnostic Value of Transthoracic Echocardiography in Patients With Anomalous Origin of the Left Coronary Artery From the Pulmonary Artery

    Science.gov (United States)

    Li, Rong-Juan; Sun, Zhonghua; Yang, Jiao; Yang, Ya; Li, Yi-Jia; Leng, Zhao-Ting; Liu, Guo-Wen; Pu, Li-Hong

    2016-01-01

    Abstract Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is a rare congenital coronary abnormality associated with early infant mortality and sudden death in adults. Transthoracic echocardiography (TTE) plays an important role in early detection and diagnosis of ALCAPA as a noninvasive modality. However, its diagnostic value is not well studied. The purpose of this study is to determine the performance of TTE in the diagnostic assessment of ALCAPA as compared with coronary CT and invasive coronary angiography. A total of 22 patients (13 women and 9 men, mean age, 12.9 ± 19.5 years) with ALCAPA who underwent echocardiographic examination for clinical diagnosis were retrospectively reviewed and analyzed. Transthoracic echocardiographic features of ALCAPA were analyzed and its diagnostic value was compared with invasive coronary angiography and coronary CT angiography (CTA) with surgical findings serving as the gold standard. Surgery was performed in all of the patients to establish the dual coronary artery system. Five underwent the Takeuchi procedure and 17 had re-implantation of the anomalous left coronary artery. Of 20 patients, echocardiographic diagnoses were in good agreement with findings at surgery, resulting in the diagnostic accuracy of 90.9%. Two cases were misdiagnosed—one as the right coronary artery to pulmonary artery fistula and the other as rheumatic heart disease. The echocardiographic features of these patients with ALCAPA included: abnormal left coronary ostium arising from the pulmonary trunk with retrograde coronary artery flow in 20 patients; enlargement of the right coronary artery in 17 patients; abundant intercoronary septal collaterals in 17 patients; and moderate and significant mitral regurgitation in 14 patients. The diagnostic accuracy of invasive coronary angiography (in 17 patients) and coronary CTA (in 9 patients) was 100%. This study shows that TTE is an accurate, noninvasive imaging modality

  20. Superficial femoral artery: current treatment options

    International Nuclear Information System (INIS)

    Tepe, Gunnar; Schmehl, Joerg; Heller, Stephan; Wiesinger, Benjamin; Claussen, Claus D.; Duda, Stephan H.

    2006-01-01

    Treatment of the superficial femoral artery (SFA) has been among the least effective of all endovascular procedures in terms of long-term patency. The relatively small vessel lumen, in conjunction with a high plaque burden, slow flow, and a high frequency of primary occlusions, contributes to a considerable rate of acute technical failures. Because of these technical limitations a much effort has been made during the past years. This manuscript should summarize the hopes and limitations of different approaches such as brachytherapy, cutting balloons, stents and stent grafts, drug-eluting stents, and drug-coated balloons. (orig.)

  1. The Application of High Temperature Superconducting Materials to Power Switches

    CERN Document Server

    March, S A; Ballarino, A

    2009-01-01

    Superconducting switches may find application in superconducting magnet systems that require energy extraction. Such superconducting switches could be bypass-switches that are operated in conjunction with a parallel resistor or dump-switches where all of the energy is dissipated in the switch itself. Bypass-switches are more suited to higher energy circuits as a portion of the energy can be dissipated in the external dump resistor. Dump- switches require less material and triggering energy as a lower switch resistance is needed to achieve the required total dump resistance. Both superconducting bypass-switches and superconducting dump-switches can be ther- mally activated. Switching times that are comparable to those obtained with mechanical bypass-switch systems can be achieved using a co-wound heater that is powered by a ca- pacitor discharge. Switches that have fast thermal diffusion times through the insulation can be modelled as a lumped system whereas those with slow thermal diffusion times were modelle...

  2. Pretreatment procedures

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    It is frequently in the patient's best interest that radiation treatments are initiated soon after the decision to treat is made. However, it is essential to good radiation therapy that the patient's treatment course be planned and beam-modifying devices be fabricated with utmost care prior to treatment. The objectives of the treatment, along with the treatment parameters and techniques necessary to achieve these objectives, must be discussed prior to initiating planning procedures. Determination of the target volume is made by the radiation oncologist; this is based on knowledge of the history of the tumor, the patterns of spread of the disease, and on diagnostic findings during the work-up of each patient. It is then necessary to obtain several measurements of the patient and also to identify the position of the target volume and of adjacent normal organs with respect to known external skin marks before the actual treatment planning is begun. Such localization can be done through several methods. The two most commonly used methods are radiographic and computed tomography (CT), both of which are discussed in this chapter. The measurements often include contours of the patient's external surface, usually in the axial plane of the central axis of the beam, and often in multiple levels within the region to be treated. Three dimensional localization and treatment planning requires thorough understanding of geometry as well as of patient positioning and immobilization. This chapter attempts to clarify some of these complicated but essential preparations for treatment

  3. Design automation of switching mode high voltage power supply for nuclear instruments

    International Nuclear Information System (INIS)

    El-araby, S.M.S.

    1999-01-01

    This paper presents an automation procedure for the design of switching mode high voltage power supplies, using Pc programming facility. The procedure permits the selection of a ready made or designed ferrite transformer. This selection could be achieved according to the designer desire; as the program includes complete information about ready made ferrite transformer through complete database. The procedure is based on suggested template circuit. Micro-Cap IV simulation package is used to verify the desired high voltage power supply design. Simulation results agree quite well with suggested procedure's results. Design aspects and development needed to increase automation capabilities are also discussed

  4. Superselective uterine arterial infusion and embolization in the treatment of ectopic pregnancies of 56 cases

    International Nuclear Information System (INIS)

    Han Chaolin; Li Changfu; Zhang Yanhua; Liu Feng; Guan Yafang; Liu Zhen; Wang Weibo; Niu Haijuan

    2008-01-01

    Objective: To probe a simple, safe, and minimally invasive method to treat ectopic pregnancy with preservation of the organs. Methods: Superselective catheterization of uterine artery through cannulation of right femoral artery was achieved in 56 patients with ectopic pregnancy. Location of the lesions involved, feeding arteries, and active bleeding were observed on angiography. 150 mg of methylamine neopterin diluted in 100 ml of saline water was infused slowly into the target artery. Small gelatin spongy particles with size of 0.5 mm in diameter were used to embolize the uterine artery until its branches were totally obliterated. Follow-up was undertaken to observe the results of the treatment. Results: Superselective uterine arterial infusion and embolization were successfully performed in all 56 patients without any related complications. Active bleeding in the peritoneum in 33 eases ceased soon after embolization. The embryos in 13 patients were confirmed to have died by ultrasound two days after the procedure. Beta-HCG value dropped to below 5 U/L within two to twelve days. Hemorrhage in the peritoneum dissolved after seven days in all cases. Mixed mass disappeared after one month. Histerosalpingography was performed three months after the procedure in 19 patients and patent fallopians were demonstrated in 11 patients. Conclusions: Superselective uterine arterial infusion and embolization is a minimally invasive procedure, which can be used to effectively treat ectopic pregnancy by disabling the ectopic embryo and embolizing leaking arteries with the advantages of preserving the fallopian tubes. (authors)

  5. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    International Nuclear Information System (INIS)

    Stoupis, Christoforos; Ludwig, Karin; Triller, Juergen; Inderbitzin, Daniel; Do, Dai-Do

    2007-01-01

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  6. Biotin Switch Assays for Quantitation of Reversible Cysteine Oxidation.

    Science.gov (United States)

    Li, R; Kast, J

    2017-01-01

    Thiol groups in protein cysteine residues can be subjected to different oxidative modifications by reactive oxygen/nitrogen species. Reversible cysteine oxidation, including S-nitrosylation, S-sulfenylation, S-glutathionylation, and disulfide formation, modulate multiple biological functions, such as enzyme catalysis, antioxidant, and other signaling pathways. However, the biological relevance of reversible cysteine oxidation is typically underestimated, in part due to the low abundance and high reactivity of some of these modifications, and the lack of methods to enrich and quantify them. To facilitate future research efforts, this chapter describes detailed procedures to target the different modifications using mass spectrometry-based biotin switch assays. By switching the modification of interest to a biotin moiety, these assays leverage the high affinity between biotin and avidin to enrich the modification. The use of stable isotope labeling and a range of selective reducing agents facilitate the quantitation of individual as well as total reversible cysteine oxidation. The biotin switch assay has been widely applied to the quantitative analysis of S-nitrosylation in different disease models and is now also emerging as a valuable research tool for other oxidative cysteine modifications, highlighting its relevance as a versatile, robust strategy for carrying out in-depth studies in redox proteomics. © 2017 Elsevier Inc. All rights reserved.

  7. Complications after transcatheter arterial chemoembolization via the inferior phrenic arteries: incidence, risk factors, and prophylaxis

    International Nuclear Information System (INIS)

    Wang Maoqiang; Liu Fengyong; Guan Jun; Gu Xiaofang; Lin Hanying; Wang Zhiqiang

    2004-01-01

    Objective: To investigate the frequency, patterns of the angiographic findings and risk factors for development of complications after transcatheter arterial chemoembolization (TACE) via the inferior phrenic artery (IPA). Methods: One hundred and sixty eight patients with hepatic tumor fed by the IPA underwent a total of 226 procedures of TACE of the IPA, with combined routine TACEO (88.7%) or without (11.3%) the combination of routine TACE of the hepatic artery. TACE of the malignancy was performed with an emulsion of iodized oil and anti-cancer agents and then followed by gelatin sponge particle injection. The complications were assessed on clinical observation, laboratory tests, and computed tomographic (CT) images after TACE of the IPA; and finally were correlated with the angiographic findings of the IPA. Results: The tumor supplied by IPA was noted at initial TACE in 25 (14.9%), at successive TACE in 97 (57.8%), after percutaneous tumor ablation guided by ultrasound in 28 (16.7%), and after hepatic surgery in 18 (10.7%) cases. The abnormal findings on arteriography showed enlargement of the IPA with tumor staining in all cases, dense non-tumor staining in 61 (36.3%), artery-to-artery anastomosis in 62(36.9%), arteriovenous shunts in 12(7.1%) cases. 96.4% of these patients complained of shoulder pain during TACE of the IPA. The cumulative complication rate after the procedure was 8.9%, including hiccup in 13 cases (5.8%), chest pain with cough and mild hemoptysis in 9 (4.0%), phrenoparalysis in 8 (3.5%), angina with abnormal ECG in 4 (1.8%), increasing of CPK, AST, and ALT significantly in 6 (2.7%), transient myeloparalysis in 2 (0.9%), and subphrenic abscess in 2 cases (0.9%). Two patients with the subphrenic abscess were successfully treated with percutaneous catheter drainage and antibiotics. The symptoms of these mild complications subsided with symptomatic treatment. Conclusions: Complications of TACE via the IPA occur in about 9% of the patients and

  8. Optimal control of switching time in switched stochastic systems with multi-switching times and different costs

    Science.gov (United States)

    Liu, Xiaomei; Li, Shengtao; Zhang, Kanjian

    2017-08-01

    In this paper, we solve an optimal control problem for a class of time-invariant switched stochastic systems with multi-switching times, where the objective is to minimise a cost functional with different costs defined on the states. In particular, we focus on problems in which a pre-specified sequence of active subsystems is given and the switching times are the only control variables. Based on the calculus of variation, we derive the gradient of the cost functional with respect to the switching times on an especially simple form, which can be directly used in gradient descent algorithms to locate the optimal switching instants. Finally, a numerical example is given, highlighting the validity of the proposed methodology.

  9. Is biliopancreatic diversion with duodenal switch a solution for patients after laparoscopic gastric banding failure?

    NARCIS (Netherlands)

    Poyck, P. P. C.; Polat, F.; Gouma, D. J.; Hesp, W. L. E. M.

    2012-01-01

    Background: Weight loss failure after laparoscopic gastric banding (LAGB) can occur in <= 25% of patients. Conversion to a malabsorptive procedure might provide more durable weight loss. The present study evaluated biliopancreatic diversion with duodenal switch (BPD/DS) after LAGB failure with a

  10. Exponential stability of switched linear systems with time-varying delay

    Directory of Open Access Journals (Sweden)

    Satiracoo Pairote

    2007-11-01

    Full Text Available We use a Lyapunov-Krasovskii functional approach to establish the exponential stability of linear systems with time-varying delay. Our delay-dependent condition allows to compute simultaneously the two bounds that characterize the exponential stability rate of the solution. A simple procedure for constructing switching rule is also presented.

  11. Electrical neuromodulation for disabling angina pectoris related to isolated stenoses of small epicardial coronary arteries.

    Science.gov (United States)

    Jessurun, G A; Hautvast, R W; DeJongste, M J; Meyler, W J; van Boven AJ; Crijns, H J

    1999-07-01

    Patients with symptomatic small vessel coronary artery disease may be inadequate candidates for revascularization procedures. They may suffer from refractory angina, which does not respond to maximal anti-anginal drug therapy. In addition to patients with end stage coronary artery disease and syndrome X, this newly defined group of subjects with an isolated stenosis of a small coronary artery may benefit from electrical neurostimulation. We describe two patients with intractable angina caused by a significant narrowing of a diagonal branch. This treatment modality should be considered as an alternative method for unsatisfactory revascularization procedures.

  12. Superior Mesenteric Artery Pseudoaneurysm Associated with Celiac Axis Occlusion Treated Using Endovascular Techniques

    International Nuclear Information System (INIS)

    Ray, Biswajit; Kuhan, Ganesh; Johnson, Brian; Nicholson, Anthony A.; Ettles, Duncan F.

    2006-01-01

    The case of a 30-year-old woman with a post-traumatic pseudoaneurysm of the superior mesenteric artery and associated celiac axis occlusion is presented. The patient was successfully treated with celiac artery recanalization and placement of a covered stent within the superior mesenteric artery. Follow-up at 3, 6, and 12 months and 3 years demonstrated patency of the covered stent and continued exclusion of the aneurysm. Although the long-term success of this procedure is unknown this management option should be considered where facilities are available, to reduce the increased morbidity associated with open surgical procedure

  13. Pressure measurements in arterial feeders of brain arteriovenous malformations before and after endovascular embolization

    International Nuclear Information System (INIS)

    Henkes, H.; Gotwald, T.F.; Brew, S.; Kaemmerer, F.; Miloslavski, E.; Kuehne, D.

    2004-01-01

    Arteriovenous malformations (AVMs) are composed of abnormal arterial and venous vessels in the brain causing arteriovenous shunts of arterialized blood directly from pial arteries to draining veins. The hemodynamics of these lesions is not well-understood. Changes in blood flow and pressure are probably related to the natural history of AVMs and may also play a major role in AVM treatment. In this study intra-arterial pressure was measured in feeding arteries of AVMs using a microcatheter that had been placed for subsequent embolization treatment (201 measurements were performed in 95 patients before and after the embolization procedure). Results show a direct relationship between pressure changes and degree of embolization. Since pressure changes during the embolization procedure are relatively small, it seems unlikely that these changes are the direct cause of rupture and periprocedural bleedings. (orig.)

  14. Sequential Effects in Deduction: Cost of Inference Switch

    Science.gov (United States)

    Milan, Emilio G.; Moreno-Rios, Sergio; Espino, Orlando; Santamaria, Carlos; Gonzalez-Hernandez, Antonio

    2010-01-01

    The task-switch paradigm has helped psychologists gain insight into the processes involved in changing from one activity to another. The literature has yielded consistent results about switch cost reconfiguration (abrupt offset in regular task-switch vs. gradual reduction in random task-switch; endogenous and exogenous components of switch cost;…

  15. Coronary Artery Anomalies in Animals

    Directory of Open Access Journals (Sweden)

    Brian A. Scansen

    2017-04-01

    Full Text Available Coronary artery anomalies represent a disease spectrum from incidental to life-threatening. Anomalies of coronary artery origin and course are well-recognized in human medicine, but have received limited attention in veterinary medicine. Coronary artery anomalies are best described in the dog, hamster, and cow though reports also exist in the horse and pig. The most well-known anomaly in veterinary medicine is anomalous coronary artery origin with a prepulmonary course in dogs, which limits treatment of pulmonary valve stenosis. A categorization scheme for coronary artery anomalies in animals is suggested, dividing these anomalies into those of major or minor clinical significance. A review of coronary artery development, anatomy, and reported anomalies in domesticated species is provided and four novel canine examples of anomalous coronary artery origin are described: an English bulldog with single left coronary ostium and a retroaortic right coronary artery; an English bulldog with single right coronary ostium and transseptal left coronary artery; an English bulldog with single right coronary ostium and absent left coronary artery with a prepulmonary paraconal interventricular branch and an interarterial circumflex branch; and a mixed-breed dog with tetralogy of Fallot and anomalous origin of all coronary branches from the brachiocephalic trunk. Coronary arterial fistulae are also described including a coronary cameral fistula in a llama cria and an English bulldog with coronary artery aneurysm and anomalous shunting vessels from the right coronary artery to the pulmonary trunk. These examples are provided with the intent to raise awareness and improve understanding of such defects.

  16. Treatment of anterior communicating artery aneurysms with Guglielmi detachable coils

    International Nuclear Information System (INIS)

    Xu Yi; Liu Jianmin; Hong Bo; Zhao Wenyuan; Huang Qinghai; Zhang Xin; Zhang Long

    2003-01-01

    Objective: To summarize the experience on endovascular treatment of anterior communicating artery aneurysms with Guglielmi detachable coils (GDCs) in 262 cases. Methods: All aneurysms were embolized with GDCs. Catheterization at both ICA was used to monitor the patency of parent arteries for patients with well-developed A1 segment of both ACAs. Microcatheter-assisted or microwire-assisted technique was undertaken to keep patency of parent arteries if the aneurysmal neck was involved with A2 segment. Thirty-four cases with multiple aneurysms had been treated successfully only in one session. Results: Complete embolization was achieved in 160 cases, while subtotal in 56 (>90%) and partial in 46 (<90%). Occlusion of parent arteries developed in 10 cases because of over-occlusion, and cerebral infarction was found in 16 cases after the procedure. Three cases with procedure-related thrombosis were revascularized by urokinase profusion. Follow-up angiograms of 3-6 months showed recanalization in 8 cases requiring a second time session. One case of recurrent aneurysm after GDC treatment was cured by surgical clipping. Conclusions: The result of endovascular treatment of anterior communicating artery aneurysms is fruitful and seems to be an alternative method in improving the rate of occlusion and reducing the cerebral infarction

  17. Evaluation of emergency transcatheter arterial embolization in intractable postpartum hemorrhage

    International Nuclear Information System (INIS)

    Qi Weihong; Wang Song; Zhan Ying

    2008-01-01

    Objective: To assess the efficacy and safety of emergency transcatheter arterial embolization in the management of intractable postpartum hemorrhage. Methods: Twenty-five patients with intractable postpartum hemorrhage were undertaken superselective catheterization into the bilateral internal iliac arteries or uterial arteries to find the causes and sites of bleeding through DSA and then followed by arterial embolization with gelfoam particles. Result: All of the 25 patients with obstetrical bleeding were successfully controlled by TAE, the procedure lasted for 25-60 min, (mean 42.5 ± 4.6 min); with both catheterization and bleeding halt successful rates of 100%. Comparison of hemoglobin and heartbeat before and after the procedure showed significance (t=29.49, P<0.01; t=16.51, P<0.01). The uterus showed reintegration on time and menstruation resumed in all patients. Conclusions: Emergency arterial embolization is a safe and effective means for control of intractable postpartum hemorrhage, providing less trauma and no severe complications, especially as an unique management for fetal postpartum hemorrhage. (authors)

  18. Endovascular treatment of three traumatic lesions of the vertebral artery

    International Nuclear Information System (INIS)

    Galvis, Victor Raul; Medina V, Francisco Jose

    2007-01-01

    The purpose is to expose the results of the endovascular treatment of three traumatic lesions of the vertebral artery. Methods: in the period from October 2005 to May 2006, three patients with traumatic lesions in the vertebral artery were treated by endovascular therapy with an age average of 32 years. All the procedures were carried out using subtraction digital angiography under anesthesiology supervision and were started with a 5,000 IU heparin bolus, previous antiplatelet medication with clopidogrel. For the treatment of the lesions covered stents and coils were used. results: there were three documented cases of traumatic lesions of the vertebral artery treated by endovascular therapy, in two cases arteriovenous fistulas were identified (between vertebral artery and internal jugular vein) with associated pseudo aneurysms, and in one case a pseudo aneurysm without fistula was found. The first patient was treated with placement of a covered stent, in a second patient the lesion was occluded with coils and a third patient required stent and coils with satisfactory repair of the lesions. Complications were not presented as a result of the procedures. Conclusions: the endovascular treatment for traumatic lesions of the vertebral artery is an alternative with minimum morbidity and reasonable costs avoiding the open surgery and conserving the permeability of the vessel when it is possible

  19. Preceding bronchial cutting for exposure of the pulmonary artery buried in scar tissue after chemoradiotherapy.

    Science.gov (United States)

    Nomori, Hiroaki; Cong, Yue; Sugimura, Hiroshi

    2017-01-01

    It is often difficult to expose the pulmonary artery buried in a scar tissue, especially in lung cancer patients that responded well to neoadjuvant chemoradiotherapy. Difficulty to access pulmonary artery branches may lead to potentially unnecessary pneumonectomy. To complete lobectomy in such cases, a technique with preceding bronchial cutting for exposure of the pulmonary artery is presented. After dissecting the pulmonary vein, the lobar bronchus is cut from the opposite side of the pulmonary artery with scissors. The back wall of the lobar bronchus is cut using a surgical knife from the luminal face, which can expose the pulmonary artery behind the bronchial stump and then complete lobectomy. Fourteen patients have been treated using the present technique, enabling complete resection by lobectomy (including sleeve lobectomy in 3 patients) without major bleeding. The present procedure can expose pulmonary artery buried in scar tissue, resulting in making the lobectomy safer.

  20. Friable but treatable: coronary artery dissections in Ehlers-Danlos syndrome.

    Science.gov (United States)

    Zago, Alexandre C; Matte, Bruno S

    2013-01-01

    Vascular Ehlers-Danlos syndrome is a rare connective tissue disorder associated with arterial dissection or rupture. Percutaneous coronary intervention (PCI) is often critical in patients with this syndrome because their coronary arteries are prone to dissection, enhancing the risk of stent borders dissection when conventional stent deployment pressures are used. Coronary artery bypass graft (CABG) treatment for these patients may also raise concerns because the left internal mammary artery is probably friable. Therefore, coronary artery revascularization in vascular Ehlers-Danlos syndrome either using PCI or CABG is challenging due to the arteries friability. A small number of cases have been published describing the friability of the vessels and associated complications; nevertheless, the optimum treatment remains unclear. We report the case of a 54-year-old woman treated successfully with PCI and CABG in two different acute coronary syndrome episodes, in which specific technical issues related to both procedures were decisive. Copyright © 2011 Wiley Periodicals, Inc.