WorldWideScience

Sample records for arterial spin labeling

  1. Myocardial arterial spin labeling

    OpenAIRE

    Kober, Frank; Jao, Terrence; Troalen, Thomas; Nayak, Krishna S.

    2016-01-01

    Arterial spin labeling (ASL) is a cardiovascular magnetic resonance (CMR) technique for mapping regional myocardial blood flow. It does not require any contrast agents, is compatible with stress testing, and can be performed repeatedly or even continuously. ASL-CMR has been performed with great success in small-animals, but sensitivity to date has been poor in large animals and humans and remains an active area of research. This review paper summarizes the development of ASL-CMR techniques, c...

  2. Superselective pseudo-continuous arterial spin labeling angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jensen-Kondering, Ulf [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Lindner, Thomas, E-mail: thomas.lindner@uksh.de [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Osch, Matthias J.P. van [C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden (Netherlands); Rohr, Axel; Jansen, Olav [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Helle, Michael [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Now with Philips GmbH Innovative Technologies, Research Laboratories, Hamburg (Germany)

    2015-09-15

    Highlights: • Superselective arterial spin labeling was capable of acquiring angiograms of individually selected arteries. • Image quality was similar compared with a routinely used time-of-flight angiography. • Superselective arterial spin labeling was utilized in patients with arterio-venous malformations and made it possible to visualize individual feeding vessels in a complete non-invasive way - Abstract: Purpose: To evaluate the utility of a novel non-contrast enhanced, vessel-selective magnetic resonance angiography (MRA) approach based on superselective pseudo-continuous arterial spin labeling (ASL) for the morphologic assessment of intracranial arteries when compared to a clinically used time-of-flight (TOF) MRA. Materials and methods: Three sets of selective ASL angiographies (right and left internal carotid artery, basilar artery) as well as one TOF data set were obtained from each of the five volunteers included in this study on a clinical 1.5T system. The depiction of arterial segments as well as their delineation was evaluated and independently analyzed by two radiologists. Additionally, the ASL angiography approach was performed in two patients suffering from arterio-venous malformations (AVM) in order to illustrate potential applications in a clinical setting. Results: In both angiography techniques, intracranial arteries and their segments (distal branches up to A5 segments of the anterior cerebral arteries, M8 segments of the middle cerebral arteries, and P5 segments of the posterior cerebral arteries) were continuously depicted with excellent inter-reader agreement (κ > 0.81). In AVM patients, reconstructed images of the TOF angiography presented similar information about the size and shape of the AVM as did superselective ASL angiography. In addition, the acquired ASL angiograms of selected vessels allowed assessing the blood supply of individually labeled arteries to the AVM which could also be confirmed by digital subtraction angiography

  3. Background suppression in arterial spin labeling MRI with a separate neck labeling coil

    OpenAIRE

    Shen, Qiang; Duong, Timothy Q.

    2011-01-01

    In arterial spin labeling (ASL) MRI to measure cerebral blood flow (CBF), pair-wise subtraction of temporally adjacent non-labeled and labeled images often can not completely cancel the background static tissue signal because of temporally fluctuating physiological noise. While background suppression (BS) by inversion nulling improves CBF temporal stability, imperfect pulses compromise CBF contrast. Conventional BS techniques may not be applicable in small animals because the arterial transit...

  4. Improving arterial spin labeling data by temporal filtering

    Science.gov (United States)

    Petr, Jan; Ferre, Jean-Christophe; Gauvrit, Jean-Yves; Barillot, Christian

    2010-03-01

    Arterial spin labeling (ASL) is an MRI method for imaging brain perfusion by magnetically labeling blood in brain feeding arteries. The perfusion is obtained from the difference between images with and without prior labeling. Image noise is one of the main problems of ASL as the difference is around 0.5-2% of the image magnitude. Usually, 20-40 pairs of images need to be acquired and averaged to reach a satisfactory quality. The images are acquired shortly after the labeling to allow the labeled blood to reach the imaged slice. A sequence of images with multiple delays is more suitable for quantification of the cerebral blood flow as it gives more information about the blood arrival and relaxation. Although the quantification methods are sensitive to noise, no filtering or only Gaussian filtering is used to denoise the data in the temporal domain prior to quantification. In this article, we propose an efficient way to use the redundancy of information in the time sequence of each pixel to suppress noise. For this purpose, the vectorial NL-means method is adapted to work in the temporal domain. The proposed method is tested on simulated and real 3T MRI data. We demonstrate a clear improvement of the image quality as well as a better performance compared to Gaussian and normal spatial NL-means filtering.

  5. Applications of arterial spin labeled MRI in the brain.

    Science.gov (United States)

    Detre, John A; Rao, Hengyi; Wang, Danny J J; Chen, Yu Fen; Wang, Ze

    2012-05-01

    Perfusion provides oxygen and nutrients to tissues and is closely tied to tissue function while disorders of perfusion are major sources of medical morbidity and mortality. It has been almost two decades since the use of arterial spin labeling (ASL) for noninvasive perfusion imaging was first reported. While initial ASL magnetic resonance imaging (MRI) studies focused primarily on technological development and validation, a number of robust ASL implementations have emerged, and ASL MRI is now also available commercially on several platforms. As a result, basic science and clinical applications of ASL MRI have begun to proliferate. Although ASL MRI can be carried out in any organ, most studies to date have focused on the brain. This review covers selected research and clinical applications of ASL MRI in the brain to illustrate its potential in both neuroscience research and clinical care.

  6. Modelling the effects of cardiac pulsations in arterial spin labelling

    International Nuclear Information System (INIS)

    It has recently been demonstrated experimentally that cardiac pulsations seem significantly to affect the arterial spin labelling (ASL) signal. In this paper, we introduce a new theoretical model to examine this effect. Existing models of ASL do not take such effects into account since they model the transit of the ASL signal assuming uniform plug flow with a single transit delay. In this study, we model cardiac pulsations through the coupling of the Navier-Stokes equations with the three-dimensional mass transport equation. Our results complement the experimental findings and suggest that the ASL signal does depend on the timing of the onset of the cardiac cycle relative to the tagging and imaging locations. However, cardiac pulsatility only appears to have a small effect on the quantification of perfusion estimates.

  7. Bolus-tracking arterial spin labelling: theoretical and experimental results

    Science.gov (United States)

    Kelly, M. E.; Blau, C. W.; Kerskens, C. M.

    2009-03-01

    Arterial spin labelling (ASL) is a magnetic resonance imaging (MRI) technique that can be used to provide a quantitative assessment of cerebral perfusion. Despite the development of a number of theoretical models to facilitate quantitative ASL, some key challenges still remain. The purpose of this study is to develop a novel quantitative ASL method based on a macroscopic model that reduces the number of variables required to describe the physiological processes involved. To this end, a novel Fokker-Planck equation consisting of stochastically varying macroscopic variables was derived from a general Langevin equation. ASL data from the rat brain was acquired using a bolus-tracking ASL protocol where a bolus of labelled spins flowing from an inversion plane in the neck into an imaging plane in the brain can be observed. Bolus durations of 1.5 s, 2.0 s and 3.0 s were used and the solution to the Fokker-Planck equation for the boundary conditions of bolus-tracking ASL was fitted to the experimental data using a least-squares fit. The mean transit time (MTT) and capillary transit time (CTT) were calculated from the first and second moments of the resultant curve respectively and the arterial transit time (ATT) was calculated by subtracting the CTT from the MTT. The average MTT, CTT and ATT values were 1.75 ± 0.22 s, 1.43 ± 0.12 s and 0.32 ± 0.04 s respectively. In conclusion, a new ASL protocol has been developed by combining the theoretical model with ASL experiments. The technique has the unique ability to provide solutions for varying bolus volumes and the generality of the new model is demonstrated by the derivation of additional solutions for the continuous and pulsed ASL (CASL and PASL) techniques.

  8. Arterial spin-labeling MR imaging of cerebral hemorrhages

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Tomoyuki [Department of Radiology, National Center for Global Health and Medicine, Tokyo (Japan); Saga University, Department of Radiology, Faculty of Medicine and Graduate School of Medicine, Saga (Japan); Nishihara, Masashi; Egashira, Yoshiaki; Azama, Shinya; Hirai, Tetsuyoshi; Kitano, Isao; Irie, Hiroyuki [Saga University, Department of Radiology, Faculty of Medicine and Graduate School of Medicine, Saga (Japan); Yakushiji, Yusuke [Saga University, Department of Neurology, Faculty of Medicine and Graduate School of Medicine, Saga (Japan); Kawashima, Masatou [Saga University, Department of Neurosurgery, Faculty of Medicine and Graduate School of Medicine, Saga (Japan)

    2015-11-15

    The purpose of this study is to identify the characteristics of brain perfusion measured by arterial spin-labeling magnetic resonance imaging (ASL-MRI) in cerebral hemorrhages. Brain blood flow values (CBF-ASL values) for cerebral and cerebellar hemispheres and segmented cerebral regions were measured by ASL-MRI in 19 putaminal hemorrhage patients and 20 thalamic hemorrhage patients in acute or subacute stages. We assessed the lateralities of CBF-ASL values and the relationships between CBF-ASL values and other imaging findings and clinical manifestations. Both the 19 putaminal hemorrhage patients and the 20 thalamic hemorrhage patients had significantly low CBF-ASL values of the contralateral cerebellum in subacute stage, suggesting that ASL-MRI might delineate crossed cerebellar diaschisis (CCD). Ipsilateral low CBF-ASL values were observed in frontal lobes and thalami with a putaminal hemorrhage and lentiform nuclei, temporal lobes, and parietal lobes with a thalamic hemorrhage, suggesting that ASL-MRI showed the ipsilateral cerebral diaschisis (ICD). In the putaminal hemorrhage patients, the hematoma volume negatively affected both the bilateral cerebellar and cerebral hemispheric CBF-ASL values. In the thalamic hemorrhage patients, a concomitant intraventricular hemorrhage caused low cerebral hemispheric CBF-ASL values. The use of ASL-MRI is sensitive to the perfusion abnormalities and could thus be helpful to estimate functional abnormalities in cerebral hemorrhage patients. (orig.)

  9. Arterial spin labeling perfusion MRI: Inter-vendor reproducibility and clinical applicability

    NARCIS (Netherlands)

    H.J.M.M. Mutsaerts

    2015-01-01

    Arterial spin labeling (ASL) is a perfusion magnetic resonance imaging (MRI) technique that non-invasively measures cerebral blood flow (CBF). The first part of this thesis concerns the inter-vendor reproducibility of ASL. Studies in this thesis show that on a total gray matter (GM) level, long-term

  10. Arterial and portal venous liver perfusion using selective spin labelling MRI

    Energy Technology Data Exchange (ETDEWEB)

    Schalkx, Hanke J.; Petersen, Esben T.; Veldhuis, Wouter B.; Leeuwen, Maarten S. van; Bosch, Maurice A.A.J. van den [University Medical Center Utrecht, Department of Radiology, HP E.01.132, Postbus 85500, Utrecht (Netherlands); Peters, Nicky H.G.M. [Atrium Medical Center Parkstad, Department of Radiology, Heerlen (Netherlands); Pluim, Josien P.W.; Stralen, Marijn van [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands)

    2015-06-01

    To investigate the feasibility of selective arterial and portal venous liver perfusion imaging with spin labelling (SL) MRI, allowing separate labelling of each blood supply. The portal venous perfusion was assessed with a pulsed EPISTAR technique and the arterial perfusion with a pseudo-continuous sequence. To explore precision and reproducibility, portal venous and arterial perfusion were separately quantified in 12 healthy volunteers pre- and postprandially (before and after meal intake). In a subgroup of 6 volunteers, the accuracy of the absolute portal perfusion and its relative postprandial change were compared with MRI flow measurements of the portal vein. The portal venous perfusion significantly increased from 63 ± 22 ml/100g/min preprandially to 132 ± 42 ml/100g/min postprandially. The arterial perfusion was lower with 35 ± 22 preprandially and 22 ± 30 ml/100g/min postprandially. The pre- and postprandial portal perfusion using SL correlated well with flow-based perfusion (r{sup 2} = 0.71). Moreover, postprandial perfusion change correlated well between SL- and flow-based quantification (r{sup 2} = 0.77). The SL results are in range with literature values. Selective spin labelling MRI of the portal venous and arterial blood supply successfully quantified liver perfusion. This non-invasive technique provides specific arterial and portal venous perfusion imaging and could benefit clinical settings where contrast agents are contraindicated. (orig.)

  11. Arterial spin labelling in imaging of renal diseases and renal allograft pathology; MRT-Perfusionsmessung mit Arterial Spin Labelling. Anwendung fuer die Niere und Transplantatniere

    Energy Technology Data Exchange (ETDEWEB)

    Hueper, Katja; Gutberlet, Marcel [Medizinische Hochschule Hannover (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Kuehn, Bernd [Siemens AG/Siemens Healthcare GmbH, Erlangen (Germany)

    2016-06-15

    Arterial Spin Labelling (ASL) is a technique for non-invasive and contrast-free assessment of perfusion with MRI. Renal ASL allows examination of renal pathophysiology, evaluation of the course of renal disease and therapy effects by longitudinal measurements as well as characterization of renal tumors. In this article, techniques of ASL will be explained and challenges of renal ASL will be emphasized. In addition, examples for clinical application of ASL for diagnosis of renal disease and renal allograft pathology will be given.

  12. Strategies for Reducing Respiratory Motion Artifacts in Renal Perfusion Imaging with Arterial Spin Labeling

    OpenAIRE

    Robson, Philip M.; Madhuranthakam, Ananth J.; Dai, Weiying; Pedrosa, Ivan; Rofsky, Neil M.; Alsop, David C.

    2009-01-01

    Arterial Spin Labeling (ASL) perfusion measurements may have many applications outside the brain. In the abdomen, severe image-artifacts can arise from motions between acquisitions of multiple signal averages in ASL, even with single-shot image-acquisition. Background suppression and respiratory motion synchronization techniques can be used to ameliorate these artifacts. Two separate in-vivo studies of renal perfusion imaging using pulsed-continuous ASL were performed. The first study assesse...

  13. Hyperemic flow heterogeneity within the calf, foot, and forearm measured with continuous arterial spin labeling MRI

    OpenAIRE

    Wu, Wen-Chau; Wang, Jiongjiong; Detre, John A.; Wehrli, Felix W.; Mohler, Emile; Ratcliffe, Sarah J.; Floyd, Thomas F

    2008-01-01

    Arterial spin labeling (ASL) is a noninvasive magnetic resonance imaging (MRI) technique for microvascular blood flow measurement. We used a continuous ASL scheme (CASL) to investigate the hyperemic flow difference between major muscle groups in human extremities. Twenty-four healthy subjects with no evidence of vascular disease were recruited. MRI was conducted on a 3.0 Tesla Siemens Trio whole body system with a transmit/receive knee coil. A nonmagnetic orthopedic tourniquet system was used...

  14. Pseudo-asymmetry of cerebral blood flow in arterial spin labeling caused by unilateral fetal-type circle of Willis: Technical limitation or a way to better understanding physiological variations of cerebral perfusion and improving arterial spin labeling acquisition?

    Science.gov (United States)

    Law-Ye, B; Geerts, B; Galanaud, D; Dormont, D; Pyatigorskaya, N

    2016-09-01

    In the recently published article, "Unilateral fetal-type circle of Willis anatomy causes right-left asymmetry in cerebral blood flow with pseudo-continuous arterial spin labeling: A limitation of arterial spin labeling-based cerebral blood flow measurements?", it was shown by the method of arterial spin labeling (ASL) that unilateral fetal-type circle of Willis could induce variation of blood flow in cerebellar and posterior cerebral artery territory. We believe that the reported observation, rather than being a limitation, gives several interesting cues for understanding the ASL sequence. In this commentary, we formulate some suggestions regarding the use of ASL in clinical practice, discuss the potential causes of the above-mentioned pseudo-asymmetry and consider future improvements of the ASL technique.

  15. Measurement of vascular water transport in human subjects using time-resolved pulsed arterial spin labelling.

    Science.gov (United States)

    Bibic, Adnan; Knutsson, Linda; Schmidt, Anders; Henningsson, Erik; Månsson, Sven; Abul-Kasim, Kasim; Åkeson, Jonas; Gunther, Matthias; Ståhlberg, Freddy; Wirestam, Ronnie

    2015-08-01

    Most approaches to arterial spin labelling (ASL) data analysis aim to provide a quantitative measure of the cerebral blood flow (CBF). This study, however, focuses on the measurement of the transfer time of blood water through the capillaries to the parenchyma (referred to as the capillary transfer time, CTT) as an alternative parameter to characterise the haemodynamics of the system. The method employed is based on a non-compartmental model, and no measurements need to be added to a common time-resolved ASL experiment. Brownian motion of labelled spins in a potential was described by a one-dimensional general Langevin equation as the starting point, and as a Fokker-Planck differential equation for the averaged distribution of labelled spins at the end point, which takes into account the effects of flow and dispersion of labelled water by the pseudorandom nature of the microvasculature and the transcapillary permeability. Multi-inversion time (multi-TI) ASL data were acquired in 14 healthy subjects on two occasions in a test-retest design, using a pulsed ASL sequence and three-dimensional gradient and spin echo (3D-GRASE) readout. Based on an error analysis to predict the size of a region of interest (ROI) required to obtain reasonably precise parameter estimates, data were analysed in two relatively large ROIs, i.e. the occipital lobe (OC) and the insular cortex (IC). The average values of CTT in OC were 260 ± 60 ms in the first experiment and 270 ± 60 ms in the second experiment. The corresponding IC values were 460 ± 130 ms and 420 ± 139 ms, respectively. Information related to the water transfer time may be important for diagnostics and follow-up of cerebral conditions or diseases characterised by a disrupted blood-brain barrier or disturbed capillary blood flow. PMID:26147641

  16. Cerebral Perfusion Measurements in Elderly with Hypertension Using Arterial Spin Labeling

    DEFF Research Database (Denmark)

    Mutsaerts, H J M M; van Dalen, J W; Heijtel, D F R;

    2015-01-01

    PURPOSE: The current study assesses the feasibility and value of crushed cerebral blood flow (CBFcrushed) and arterial transit time (ATT) estimations for large clinical imaging studies in elderly with hypertension. MATERIAL AND METHODS: Two pseudo-continuous arterial spin labeling (ASL) scans with...... (CBFcrushed) and without flow crushers (CBFnon-crushed) were performed in 186 elderly with hypertension, from which CBF and ATT maps were calculated. Standard flow territory maps were subdivided into proximal, intermediate and distal flow territories, based on the measured ATT. The coefficient of variation...... group analyses in elderly with hypertension. The obtained flow territories provide knowledge on vascular anatomy of elderly with hypertension and can be used in future studies to investigate regional vascular effects....

  17. Reduction in cerebral perfusion after heroin administration: a resting state arterial spin labeling study.

    Directory of Open Access Journals (Sweden)

    Niklaus Denier

    Full Text Available Heroin dependence is a chronic relapsing brain disorder, characterized by the compulsion to seek and use heroin. Heroin itself has a strong potential to produce subjective experiences characterized by intense euphoria, relaxation and release from craving. The neurofunctional foundations of these perceived effects are not well known. In this study, we have used pharmacological magnetic resonance imaging (phMRI in 15 heroin-dependent patients from a stable heroin-assisted treatment program to observe the steady state effects of heroin (60 min after administration. Patients were scanned in a cross-over and placebo controlled design. They received an injection of their regular dose of heroin or saline (placebo before or after the scan. As phMRI method, we used a pulsed arterial spin labeling (ASL sequence based on a flow-sensitive alternating inversion recovery (FAIR spin labeling scheme combined with a single-shot 3D GRASE (gradient-spin echo readout on a 3 Tesla scanner. Analysis was performed with Statistical Parametric Mapping (SPM 8, using a general linear model for whole brain comparison between the heroin and placebo conditions. We found that compared to placebo, heroin was associated with reduced perfusion in the left anterior cingulate cortex (ACC, the left medial prefrontal cortex (mPFC and in the insula (both hemispheres. Analysis of extracted perfusion values indicate strong effect sizes and no gender related differences. Reduced perfusion in these brain areas may indicate self- and emotional regulation effects of heroin in maintenance treatment.

  18. Noninvasive measurements of regional cerebral perfusion in preterm and term neonates by magnetic resonance arterial spin labeling

    DEFF Research Database (Denmark)

    Miranda Gimenez-Ricco, Maria Jo; Olofsson, K; Sidaros, Karam

    2006-01-01

    Magnetic resonance arterial spin labeling (ASL) at 3 Tesla has been investigated as a quantitative technique for measuring regional cerebral perfusion (RCP) in newborn infants. RCP values were measured in 49 healthy neonates: 32 preterm infants born before 34 wk of gestation and 17 term-born neon......Magnetic resonance arterial spin labeling (ASL) at 3 Tesla has been investigated as a quantitative technique for measuring regional cerebral perfusion (RCP) in newborn infants. RCP values were measured in 49 healthy neonates: 32 preterm infants born before 34 wk of gestation and 17 term...

  19. Two analytical solutions for a model of pulsed arterial spin labeling with randomized blood arrival times

    Science.gov (United States)

    Hrabe, J.; Lewis, D. P.

    2004-03-01

    A fairly general theoretical model for pulsed arterial spin labeling perfusion methods has been available for some time but analytical solutions were derived for only a small number of arterial blood input functions. These mostly assumed a sudden and simultaneous arrival of the tagged blood into the imaged region. More general cases had to be handled numerically. We present analytical solutions for two more realistic arterial input functions. They both allow the arrival times of the molecules of tagged arterial blood to be statistically distributed. We consider cases of (1) a uniform distribution on a finite time interval and (2) a normal distribution characterized by its mean and standard deviation. These models are physiologically meaningful because the statistical nature of the arrival times reflects the distribution of velocities and path lengths that the blood water molecules undertake from the tagging region to the imaged region. The model parameters can be estimated from the measured dependency of the perfusion signal on the tag inversion time.

  20. Arterial spin labeling in patients with chic cerebral artery steno-occlusive disease - Correlation with {sup 15}O-PET

    Energy Technology Data Exchange (ETDEWEB)

    Kamano, Hironori; Yoshiura, Takashi; Hiwatashi, Akio; Abe, Koichiro; Yamashita, Koji; Honda, Hiroshi [Dept. of Clinical Radiology, Graduate School of Medical Sciences, Kyushu Univ., Fukuoka (Japan)], e-mail: tsu@radiol.med.kyushu-u.ac.jp; Togao, Osamu [Dept. of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu Univ., Fukuoka (Japan)

    2013-02-15

    Background: Heterogeneity of arterial transit time due to cerebral artery steno-occlusive lesions hampers accurate regional cerebral blood flow measurement by arterial spin labeling (ASL). Purpose: To assess the feasibility of regional cerebral blood flow measurement by ASL with multiple-delay time sampling in patients with steno-occlusive diseases by comparing with positron emission tomography (PET), and to determine whether regional arterial transit time measured by this ASL technique is correlated with regional mean transit time, a PET index of perfusion pressure. Material and Methods: Sixteen patients with steno-occlusive diseases received both ASL and {sup 15}O-PET. The mean regional cerebral blood flow measured by ASL and PET, regional arterial transit time by ASL, and regional mean transit time by PET were obtained by a region-of-interest analysis. Correlation between regional cerebral blood flow by ASL and that by PET, and correlation between regional arterial transit time by ASL and regional mean transit time by PET were tested using Pearson's correlation coefficient for both absolute and relative values. A multivariate regression analysis was performed to test whether regional arterial transit time by ASL was a significant contributor in modeling regional mean transit time by PET after controlling the effect of regional cerebral blood flow by ASL. Results: A significant positive correlation was found between regional cerebral blood flow by ASL and that by PET for both absolute (r = 0.520, P < 0.0001) and relative (r = 0.691, P < 0.0001) values. A significant positive correlation was found between regional arterial transit time by ASL and regional mean transit time by PET both for absolute (r = 0.369, P = 0.0002) and relative (r = 0.443, P < 0.0001) values. The regression analysis revealed that regional arterial transit time by ASL was a significant contributor in modeling regional mean transit time by PET after controlling regional cerebral blood flow by

  1. 3D Pseudocontinuous arterial spin labeling in routine clinical practice: A review of clinically significant artifacts.

    Science.gov (United States)

    Amukotuwa, Shalini A; Yu, Caroline; Zaharchuk, Gregory

    2016-01-01

    Arterial spin labeling (ASL) is a completely noninvasive magnetic resonance imaging (MRI) perfusion method for quantitatively measuring cerebral blood flow utilizing magnetically labeled arterial water. Advances in the technique have enabled the major MRI vendors to make the sequence available to the clinical neuroimaging community. Consequently, ASL is being increasingly incorporated into the routine neuroimaging protocol. Although a variety of ASL techniques are available, the ISMRM Perfusion Study Group and the European ASL in Dementia Consortium have released consensus guidelines recommending standardized implementation of 3D pseudocontinuous ASL with background suppression. The purpose of this review, aimed at the large number of neuroimaging clinicians who have either no or limited experience with this 3D pseudocontinuous ASL, is to discuss the common and clinically significant artifacts that may be encountered with this technique. While some of these artifacts hinder accurate interpretation of studies, either by degrading the images or mimicking pathology, there are other artifacts that are of clinical utility, because they increase the conspicuity of pathology. Cognizance of these artifacts will help the physician interpreting ASL to avoid potential diagnostic pitfalls, and increase their level of comfort with the technique.

  2. Sickle cell anemia: reference values of cerebral blood flow determined by continuous arterial spin labeling MRI.

    Science.gov (United States)

    Arkuszewski, M; Krejza, J; Chen, R; Melhem, E R

    2013-04-01

    Sickle cell anemia (SCA) is a chronic illness associated with progressive deterioration in patients' quality of life. The major complications of SCA are cerebrovascular accidents (CVA) such as asymptomatic cerebral infarct or overt stroke. The risk of CVA may be related to chronic disturbances in cerebral blood flow (CBF), but the thresholds of "normal" steady-state CBF are not well established. The reference tolerance limits of CBF can be useful to estimate the risk of CVA in asymptomatic children with SCA, who are negative for hyperemia or evidence of arterial narrowing. Continuous arterial spin labeling (CASL) MR perfusion allows for non-invasive quantification of global and regional CBF. To establish such reference tolerance limits we performed CASL MR examinations on a 3-Tesla MR scanner in a carefully selected cohort of 42 children with SCA (mean age, 8.1±3.3 years; range limits, 2.3-14.4 years; 24 females), who were not on chronic transfusion therapy, had no history of overt stroke or transient ischemic attack, were free of signs and symptoms of focal vascular territory ischemic brain injury, did not have intracranial arterial narrowing on MR angiography and were at low risk for stroke as determined by transcranial Doppler ultrasonography.

  3. Intra- and multicenter reproducibility of pulsed, continuous and pseudo-continuous arterial spin labeling methods for measuring cerebral perfusion

    NARCIS (Netherlands)

    J.K.M. Gevers; M.J. van Osch; R.P.H. Bokkers; D.A. Kies; W.M. Teeuwisse; C.B. Majoie; J. Hendrikse; A.J. Nederveen

    2011-01-01

    Intra- and multicenter reproducibility of currently used arterial spin labeling (ASL) methods were assessed at three imaging centers in the Netherlands, equipped with Philips 3TMR scanners. Six healthy participants were scanned twice at each site. The imaging protocol consisted of continuous ASL (CA

  4. Improving perfusion quantification in arterial spin labeling for delayed arrival times by using optimized acquisition schemes

    Energy Technology Data Exchange (ETDEWEB)

    Kramme, Johanna [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); Univ. Bremen (Germany). Faculty of Physics and Electronics; Gregori, Johannes [mediri GmbH, Heidelberg (Germany); Diehl, Volker [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); ZEMODI (Zentrum fuer morderne Diagnostik), Bremen (Germany); Madai, Vince I.; Sobesky, Jan [Charite-Universitaetsmedizin Berlin (Germany). Center for Stroke Research Berlin (CSB); Charite-Universitaetsmedizin Berlin (Germany). Dept. of Neurology; Samson-Himmelstjerna, Frederico C. von [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); Charite-Universitaetsmedizin Berlin (Germany). Center for Stroke Research Berlin (CSB); Charite-Universitaetsmedizin Berlin (Germany). Dept. of Neurology; Lentschig, Markus [ZEMODI (Zentrum fuer morderne Diagnostik), Bremen (Germany); Guenther, Matthias [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); Univ. Bremen (Germany). Faculty of Physics and Electronics; mediri GmbH, Heidelberg (Germany)

    2015-07-01

    The improvement in Arterial Spin Labeling (ASL) perfusion quantification, especially for delayed bolus arrival times (BAT), with an acquisition redistribution scheme mitigating the T1 decay of the label in multi-TI ASL measurements is investigated. A multi inflow time (TI) 3D-GRASE sequence is presented which adapts the distribution of acquisitions accordingly, by keeping the scan time constant. The MR sequence increases the number of averages at long TIs and decreases their number at short TIs and thus compensating the T1 decay of the label. The improvement of perfusion quantification is evaluated in simulations as well as in-vivo in healthy volunteers and patients with prolonged BATs due to age or steno-occlusive disease. The improvement in perfusion quantification depends on BAT. At healthy BATs the differences are small, but become larger for longer BATs typically found in certain diseases. The relative error of perfusion is improved up to 30% at BATs > 1500 ms in comparison to the standard acquisition scheme. This adapted acquisition scheme improves the perfusion measurement in comparison to standard multi-TI ASL implementations. It provides relevant benefit in clinical conditions that cause prolonged BATs and is therefore of high clinical relevance for neuroimaging of steno-occlusive diseases.

  5. The QUASAR reproducibility study, Part II: Results from a multi center Arterial Spin Labeling test-retest Study

    OpenAIRE

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier

    2009-01-01

    Arterial Spin Labeling (ASL) is a method to measure perfusion using magnetically labeled blood water as an endogenous tracer. Being fully non-invasive, this technique is attractive for longitudinal studies of cerebral blood flow in healthy and diseased individuals, or as a surrogate marker of metabolism. So far, ASL has been restricted mostly to specialist centers due to a generally low SNR of the method and potential issues with user-dependent analysis needed to obtain quantitative measureme...

  6. Assesment of perfusion in glial tumors with arterial spin labeling; comparison with dynamic susceptibility contrast method

    Energy Technology Data Exchange (ETDEWEB)

    Cebeci, H, E-mail: hcebeci16@gmail.com [Department of Radiology, Uludag University Medical School, Bursa (Turkey); Aydin, O [Department of Radiology, Uludag University Medical School, Bursa (Turkey); Ozturk-Isik, E; Gumus, C [Department of Biomedical Engineering, Yeditepe University, Istanbul (Turkey); Inecikli, F [Department of Radiology, Kanuni Sultan Suleyman Educational and Research Hospital, Istanbul (Turkey); Bekar, A; Kocaeli, H [Department of Neurosurgery, Uludag University Medical School, Bursa (Turkey); Hakyemez, B [Department of Radiology, Uludag University Medical School, Bursa (Turkey)

    2014-10-15

    Highlights: • We compared the perfusion parameters obtained with both DSC and ASL perfusion imaging methods. • In ASL perfusion imaging, we also created quantitative CBF maps. • All patients included in the study had histopathological diagnose. • All MR examinations are done with 3T MR imaging system. - Abstract: Purpose: Arterial spin labeling perfusion imaging (ASL-PI) is a non-invasive perfusion imaging method that can be used for evaluation and quantification of cerebral blood flow (CBF). Aim of our study was to evaluating the efficiency of ASL in histopathological grade estimation of glial tumors and comparing findings with dynamic susceptibility contrast perfusion imaging (DSC-PI) method. Methods: This study involved 33 patients (20 high-grade and 13 low-grade gliomas). Multiphase multislice pulsed ASL MRI sequence and a first-passage gadopentetate dimeglumine T2*-weighted gradient-echo single-shot echo-planar sequence were acquired for all the patients. For each patient, perfusion relative signal intensity (rSI), CBF and relative CBF (rCBF) on ASL-PI and relative cerebral blood volume (rCBV) and relative cerebral blood flow (rCBF) values on DSC-PI were determined. The relative signal intensity of each tumor was determined as the maximal SI within the tumor divided by SI within symetric region in the contralateral hemisphere on ASL-PI. rCBV and rCBF were calculated by deconvolution of an arterial input function. Relative values of the lesions were obtained by dividing the values to the normal appearing symmetric region on the contralateral hemisphere. For statistical analysis, Mann–Whitney ranksum test was carried out. Receiver operating characteristic curve (ROC) analysis was performed to assess the relationship between the rCBF-ASL, rSI-ASL, rCBV and rCBF ratios and grade of gliomas. Their cut-off values permitting best discrimination was calculated. The correlation between rCBV, rCBF, rSI-ASL and rCBF-ASL and glioma grade was assessed using

  7. Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Lanzman, Rotem S.; Wittsack, Hans-Joerg; Bilk, Philip; Kroepil, Patric; Blondin, Dirk [University Hospital Duesseldorf, Department of Radiology, Duesseldorf (Germany); Martirosian, Petros; Schick, Fritz [University Hospital Tuebingen, Section for Experimental Radiology, Department of Diagnostic Radiology, Tuebingen (Germany); Zgoura, Panagiota; Voiculescu, Adina [University Hospital Duesseldorf, Department of Nephrology, Duesseldorf (Germany)

    2010-06-15

    To quantify renal allograft perfusion in recipients with stable allograft function and acute decrease in allograft function using nonenhanced flow-sensitive alternating inversion recovery (FAIR)-TrueFISP arterial spin labeling (ASL) MR imaging. Following approval of the local ethics committee, 20 renal allograft recipients were included in this study. ASL perfusion measurement and an anatomical T2-weighted single-shot fast spin-echo (HASTE) sequence were performed on a 1.5-T scanner (Magnetom Avanto, Siemens, Erlangen, Germany). T2-weighted MR urography was performed in patients with suspected ureteral obstruction. Patients were assigned to three groups: group a, 6 patients with stable allograft function over the previous 4 months; group b, 7 patients with good allograft function who underwent transplantation during the previous 3 weeks; group c, 7 allograft recipients with an acute deterioration of renal function. Mean cortical perfusion values were 304.8 {+-} 34.4, 296.5 {+-} 44.1, and 181.9 {+-} 53.4 mg/100 ml/min for groups a, b and c, respectively. Reduction in cortical perfusion in group c was statistically significant. Our results indicate that ASL is a promising technique for nonenhanced quantification of cortical perfusion of renal allografts. Further studies are required to determine the clinical value of ASL for monitoring renal allograft recipients. (orig.)

  8. Demonstration of pulmonary perfusion heterogeneity induced by gravity and lung inflation using arterial spin labeling

    International Nuclear Information System (INIS)

    Objective: To evaluate the effect of gravity and lung inflation on pulmonary perfusion heterogeneity in human lung using an arterial spin labeling (ASL) sequence called flow sensitive alternating inversion recovery (FAIR). Materials and methods: Magnetic resonance imaging of lung perfusion using arterial spin labeling sequence was performed in supine position in ten healthy volunteers on a 1.5 T whole body scanner (GE Healthcare). Five coronal slices at an interval of 3 cm from dorsal to ventral (labeled as P3, P6, P9, P12, P15, sequently) were obtained when the volunteers performed breath holding on end expiration and the relative pulmonary blood flow (rPBF) was measured. Then, another coronal perfusion-weighted image of P3 slice was obtained on end inspiration. Tagging efficiency of pulmonary parenchyma with IR (ΔSI), rPBF and area of the P3 slice were analyzed. Results: (1) Along the direction of gravity, a gradient was visually perceived as a vertical increase in rPBF. There were significant statistic differences in rPBF between any two coronal planes except that between P12 and P15. In supine position, regression coefficients of right and left lung were -4.98 and -5.16, respectively. This means that rPBF decreased 4.98 (right) and 5.16 (left) for each centimeter above the dorsal. No statistical difference was seen between ROIs placed along iso-gravitational plane. (2) For a same slice, there were significant statistic differences in ΔSI, rPBF and area at different respiratory phases (P < 0.05). Greater ΔSI and more perfusion were observed on end expiration than on end inspiration. The area was larger on end inspiration than on end expiration. Conclusion: Both gravity and respiratory phase are important determinants of pulmonary perfusion heterogeneity. FAIR is sensitive to demonstrate gravity- and respiratory phase-dependent differences in lung perfusion. Positioning the patient so that the area of interest is down-gravity and asking patient to hold breath

  9. Demonstration of pulmonary perfusion heterogeneity induced by gravity and lung inflation using arterial spin labeling

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli7938@chinaren.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com; Sun Fei [GE Healthcare (China)], E-mail: Fei.sun@med.ge.com

    2010-02-15

    Objective: To evaluate the effect of gravity and lung inflation on pulmonary perfusion heterogeneity in human lung using an arterial spin labeling (ASL) sequence called flow sensitive alternating inversion recovery (FAIR). Materials and methods: Magnetic resonance imaging of lung perfusion using arterial spin labeling sequence was performed in supine position in ten healthy volunteers on a 1.5 T whole body scanner (GE Healthcare). Five coronal slices at an interval of 3 cm from dorsal to ventral (labeled as P3, P6, P9, P12, P15, sequently) were obtained when the volunteers performed breath holding on end expiration and the relative pulmonary blood flow (rPBF) was measured. Then, another coronal perfusion-weighted image of P3 slice was obtained on end inspiration. Tagging efficiency of pulmonary parenchyma with IR ({delta}SI), rPBF and area of the P3 slice were analyzed. Results: (1) Along the direction of gravity, a gradient was visually perceived as a vertical increase in rPBF. There were significant statistic differences in rPBF between any two coronal planes except that between P12 and P15. In supine position, regression coefficients of right and left lung were -4.98 and -5.16, respectively. This means that rPBF decreased 4.98 (right) and 5.16 (left) for each centimeter above the dorsal. No statistical difference was seen between ROIs placed along iso-gravitational plane. (2) For a same slice, there were significant statistic differences in {delta}SI, rPBF and area at different respiratory phases (P < 0.05). Greater {delta}SI and more perfusion were observed on end expiration than on end inspiration. The area was larger on end inspiration than on end expiration. Conclusion: Both gravity and respiratory phase are important determinants of pulmonary perfusion heterogeneity. FAIR is sensitive to demonstrate gravity- and respiratory phase-dependent differences in lung perfusion. Positioning the patient so that the area of interest is down-gravity and asking patient

  10. A neuroradiologist's guide to arterial spin labeling MRI in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Grade, M. [Queen Square, UCL Institute of Neurology, London (United Kingdom); Stanford School of Medicine, Stanford, CA (United States); Hernandez Tamames, J.A. [Rey Juan Carlos University, Medical Image Analysis and Biometry Laboratory, Madrid (Spain); Erasmus MC - University Medical Centre Rotterdam, Department of Radiology, PO Box 2040, Rotterdam (Netherlands); Pizzini, F.B. [Queen Square, UCL Institute of Neurology, London (United Kingdom); Verona University Hospital, Neuroradiology, Department of Diagnostics and Pathology, Verona (Italy); Achten, E. [Ghent University Hospital, Neuroradiology, Department of Radiology, Ghent (Belgium); Golay, X. [Queen Square, UCL Institute of Neurology, London (United Kingdom); Smits, M. [Erasmus MC - University Medical Centre Rotterdam, Department of Radiology, PO Box 2040, Rotterdam (Netherlands)

    2015-12-15

    Arterial spin labeling (ASL) is a non-invasive MRI technique to measure cerebral blood flow (CBF). This review provides a practical guide and overview of the clinical applications of ASL of the brain, as well its potential pitfalls. The technical and physiological background is also addressed. At present, main areas of interest are cerebrovascular disease, dementia and neuro-oncology. In cerebrovascular disease, ASL is of particular interest owing to its quantitative nature and its capability to determine cerebral arterial territories. In acute stroke, the source of the collateral blood supply in the penumbra may be visualised. In chronic cerebrovascular disease, the extent and severity of compromised cerebral perfusion can be visualised, which may be used to guide therapeutic or preventative intervention. ASL has potential for the detection and follow-up of arteriovenous malformations. In the workup of dementia patients, ASL is proposed as a diagnostic alternative to PET. It can easily be added to the routinely performed structural MRI examination. In patients with established Alzheimer's disease and frontotemporal dementia, hypoperfusion patterns are seen that are similar to hypometabolism patterns seen with PET. Studies on ASL in brain tumour imaging indicate a high correlation between areas of increased CBF as measured with ASL and increased cerebral blood volume as measured with dynamic susceptibility contrast-enhanced perfusion imaging. Major advantages of ASL for brain tumour imaging are the fact that CBF measurements are not influenced by breakdown of the blood-brain barrier, as well as its quantitative nature, facilitating multicentre and longitudinal studies. (orig.)

  11. Mapping Long-Term Functional Changes in Cerebral Blood Flow by Arterial Spin Labeling

    Science.gov (United States)

    Ssali, Tracy; Anazodo, Udunna C.; Bureau, Yves; MacIntosh, Bradley J.; Günther, Matthias; St. Lawrence, Keith

    2016-01-01

    Although arterial spin labeling (ASL) is appealing for mapping long-term changes in functional activity, inter-sessional variations in basal blood flow, arterial transit times (ATTs), and alignment errors, can result in significant false activation when comparing images from separate sessions. By taking steps to reduce these sources of noise, this study assessed the ability of ASL to detect functional CBF changes between sessions. ASL data were collected in three sessions to image ATT, resting CBF and CBF changes associated with motor activation (7 participants). Activation maps were generated using rest and task images acquired in the same session and from sessions separated by up to a month. Good agreement was found when comparing between-session activation maps to within-session activation maps with only a 16% decrease in precision (within-session: 90 ± 7%) and a 13% decrease in the Dice similarity (within-session: 0.75 ± 0.07) coefficient after a month. In addition, voxel-wise reproducibility (within-session: 4.7 ± 4.5%) and reliability (within-session: 0.89 ± 0.20) of resting grey-matter CBF decreased by less than 18% for the between-session analysis relative to within-session values. ATT variability between sessions (5.0 ± 2.7%) was roughly half the between-subject variability, indicating that its effects on longitudinal CBF were minimal. These results demonstrate that conducting voxel-wise analysis on CBF images acquired on different days is feasible with only modest loss in precision, highlighting the potential of ASL for longitudinal studies. PMID:27706218

  12. Combined Diffusion Tensor Imaging and Arterial Spin Labeling as Markers of Early Parkinson’s disease

    Science.gov (United States)

    Wei, Xiaobo; Yan, Ronghua; Chen, Zhaoyu; Weng, Ruihui; Liu, Xu; Gao, Huimin; Xu, Xiaofeng; Kang, Zhuang; Liu, Zhexing; Guo, Yan; Liu, Zhenhua; Larsen, Jan Petter; Wang, Jin; Tang, Beisha; Hallett, Mark; Wang, Qing

    2016-01-01

    This study aimed to identify a PD-specific MRI pattern using combined diffusion tensor imaging (DTI) and arterial spin labeling (ASL) to discriminate patients with early PD from healthy subjects and evaluate disease status. Twenty-one early and 22 mid-late PD patients, and 22 healthy, age/gender-matched controls underwent 3-T MRI with apparent diffusion coefficient (ADC), fractional anisotropy (FA), fiber number (FN) and cerebral blood flow (CBF) measurements. We found that compared with healthy subjects, there was a profound reduction in FN passing through the SN in PD. FA in the SN and CBF in the caudate nucleus were inversely correlated with motor dysfunction. A negative correlation was observed between FA in the hippocampus (Hip) and the NMSS-Mood score, whereas CBF in the Hip and the prefrontal cortex(PFC) correlated with declined cognition. Stratified five-fold cross-validation identified FA in the SN(FA-SNAv), CBF in the PFC(CBF-PFCAv) and FA in the parietal white matter(FA-PWMAv), and the combination of these measurements offered relatively high accuracy (AUC 0.975, 90% sensitivity and 100% specificity) in distinguishing those with early PD from healthy subjects. We demonstrate that the decreased FNs through SN in combination with changes in FA-SNAv, CBF-PFCAv and FA-PWMAv values might serve as potential markers of early-stage PD. PMID:27646647

  13. Arterial spin-labelling perfusion MRI and outcome in neonates with hypoxic-ischemic encephalopathy

    International Nuclear Information System (INIS)

    Hyperperfusion may be related to outcome in neonates with hypoxic-ischemic encephalopathy (HIE). The purpose of this study was to evaluate whether arterial spin labelling (ASL) perfusion is associated with outcome in neonates with HIE and to compare the predictive value of ASL MRI to known MRI predictive markers. Twenty-eight neonates diagnosed with HIE and assessed with MR imaging (conventional MRI, diffusion-weighted MRI, MR spectroscopy [MRS], and ASL MRI) were included. Perfusion in the basal ganglia and thalami was measured. Outcome at 9 or 18 months of age was scored as either adverse (death or cerebral palsy) or favourable. The median (range) perfusion in the basal ganglia and thalami (BGT) was 63 (28-108) ml/100 g/min in the neonates with adverse outcome and 28 (12-51) ml/100 g/min in the infants with favourable outcome (p 2 = 0.86, p < 0.001). Higher ASL perfusion values in neonates with HIE are associated with a worse neurodevelopmental outcome. A combination of the MRS and ASL MRI information is the best predictor of outcome. (orig.)

  14. Human brain: reliability and reproducibility of pulsed arterial spin-labeling perfusion MR imaging.

    Science.gov (United States)

    Jahng, Geon-Ho; Song, Enmin; Zhu, Xiao-Ping; Matson, Gerald B; Weiner, Michael W; Schuff, Norbert

    2005-03-01

    The Committee of Human Research of the University of California San Francisco approved this study, and all volunteers provided written informed consent. The goal of this study was to prospectively determine the global and regional reliability and reproducibility of noninvasive brain perfusion measurements obtained with different pulsed arterial spin-labeling (ASL) magnetic resonance (MR) imaging methods and to determine the extent to which within-subject variability and random noise limit reliability and reproducibility. Thirteen healthy volunteers were examined twice within 2 hours. The pulsed ASL methods compared in this study differ mainly with regard to magnetization transfer and eddy current effects. There were two main results: (a) Pulsed ASL MR imaging consistently had high measurement reliability (intraclass correlation coefficients greater than 0.75) and reproducibility (coefficients of variation less than 8.5%), and (b) random noise rather than within-subject variability limited reliability and reproducibility. It was concluded that low signal-to-noise ratios substantially limit the reliability and reproducibility of perfusion measurements.

  15. Combined Diffusion Tensor Imaging and Arterial Spin Labeling as Markers of Early Parkinson's disease.

    Science.gov (United States)

    Wei, Xiaobo; Yan, Ronghua; Chen, Zhaoyu; Weng, Ruihui; Liu, Xu; Gao, Huimin; Xu, Xiaofeng; Kang, Zhuang; Liu, Zhexing; Guo, Yan; Liu, Zhenhua; Larsen, Jan Petter; Wang, Jin; Tang, Beisha; Hallett, Mark; Wang, Qing

    2016-09-20

    This study aimed to identify a PD-specific MRI pattern using combined diffusion tensor imaging (DTI) and arterial spin labeling (ASL) to discriminate patients with early PD from healthy subjects and evaluate disease status. Twenty-one early and 22 mid-late PD patients, and 22 healthy, age/gender-matched controls underwent 3-T MRI with apparent diffusion coefficient (ADC), fractional anisotropy (FA), fiber number (FN) and cerebral blood flow (CBF) measurements. We found that compared with healthy subjects, there was a profound reduction in FN passing through the SN in PD. FA in the SN and CBF in the caudate nucleus were inversely correlated with motor dysfunction. A negative correlation was observed between FA in the hippocampus (Hip) and the NMSS-Mood score, whereas CBF in the Hip and the prefrontal cortex(PFC) correlated with declined cognition. Stratified five-fold cross-validation identified FA in the SN(FA-SNAv), CBF in the PFC(CBF-PFCAv) and FA in the parietal white matter(FA-PWMAv), and the combination of these measurements offered relatively high accuracy (AUC 0.975, 90% sensitivity and 100% specificity) in distinguishing those with early PD from healthy subjects. We demonstrate that the decreased FNs through SN in combination with changes in FA-SNAv, CBF-PFCAv and FA-PWMAv values might serve as potential markers of early-stage PD.

  16. Arterial spin-labelling perfusion MRI and outcome in neonates with hypoxic-ischemic encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Vis, Jill B. de; Hendrikse, Jeroen [University Medical Center Utrecht, Department of Radiology, HP E 01.132, P.O. Box 85500, Utrecht (Netherlands); Petersen, Esben T. [University Medical Center Utrecht, Department of Radiology, HP E 01.132, P.O. Box 85500, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiotherapy, Utrecht (Netherlands); Vries, Linda S. de; Bel, Frank van; Alderliesten, Thomas; Negro, Simona; Groenendaal, Floris; Benders, Manon J.N.L. [Wilhelmina Children' s Hospital/University Medical Center Utrecht, Department of Neonatology, Utrecht (Netherlands)

    2015-01-15

    Hyperperfusion may be related to outcome in neonates with hypoxic-ischemic encephalopathy (HIE). The purpose of this study was to evaluate whether arterial spin labelling (ASL) perfusion is associated with outcome in neonates with HIE and to compare the predictive value of ASL MRI to known MRI predictive markers. Twenty-eight neonates diagnosed with HIE and assessed with MR imaging (conventional MRI, diffusion-weighted MRI, MR spectroscopy [MRS], and ASL MRI) were included. Perfusion in the basal ganglia and thalami was measured. Outcome at 9 or 18 months of age was scored as either adverse (death or cerebral palsy) or favourable. The median (range) perfusion in the basal ganglia and thalami (BGT) was 63 (28-108) ml/100 g/min in the neonates with adverse outcome and 28 (12-51) ml/100 g/min in the infants with favourable outcome (p < 0.01). The area-under-the-curve was 0.92 for ASL MRI, 0.97 for MRI score, 0.96 for Lac/NAA and 0.92 for ADC in the BGT. The combination of Lac/NAA and ASL MRI results was the best predictor of outcome (r {sup 2} = 0.86, p < 0.001). Higher ASL perfusion values in neonates with HIE are associated with a worse neurodevelopmental outcome. A combination of the MRS and ASL MRI information is the best predictor of outcome. (orig.)

  17. Arterial Spin Labeling Perfusion Study in the Patients with Subacute Mild Traumatic Brain Injury.

    Directory of Open Access Journals (Sweden)

    Che-Ming Lin

    Full Text Available This study uses a MRI technique, three-dimension pulse continuous arterial spin labeling (3D-PCASL, to measure the patient's cerebral blood flow (CBF at the subacute stage of mild traumatic brain injury (MTBI in order to analyze the relationship between cerebral blood flow and neurocognitive deficits.To provide the relationship between cortical CBF and neuropsychological dysfunction for the subacute MTBI patients.After MTBI, perfusion MR imaging technique (3D-PCASL measures the CBF of MTBI patients (n = 23 within 1 month and that of normal controls (n = 22 to determine the quantity and location of perfusion defect. The correlation between CBF abnormalities and cognitive deficits was elucidated by combining the results of the neuropsychological tests of the patients.We observed a substantial reduction in CBF in the bilateral frontal and left occipital cortex as compared with the normal persons. In addition, there were correlation between post concussive symptoms (including dizziness and simulator sickness and CBF in the hypoperfused areas. The more severe symptom was correlated with higher CBF in bilateral frontal and left occipital lobes.First, this study determined that despite no significant abnormality detected on conventional CT and MRI studies, hypoperfusion was observed in MTBI group using 3D-PCASL technique in subacute stage, which suggested that this approach may increase sensitivity to MTBI. Second, the correlation between CBF and the severity of post concussive symptoms suggested that changes in cerebral hemodynamics may play a role in pathophysiology underlies the symptoms.

  18. 3D GRASE PROPELLER: Improved Image Acquisition Technique for Arterial Spin Labeling Perfusion Imaging

    Science.gov (United States)

    Tan, Huan; Hoge, W. Scott; Hamilton, Craig A.; Günther, Matthias; Kraft, Robert A.

    2014-01-01

    Arterial spin labeling (ASL) is a non-invasive technique that can quantitatively measure cerebral blood flow (CBF). While traditionally ASL employs 2D EPI or spiral acquisition trajectories, single-shot 3D GRASE is gaining popularity in ASL due to inherent SNR advantage and spatial coverage. However, a major limitation of 3D GRASE is through-plane blurring caused by T2 decay. A novel technique combining 3D GRASE and a PROPELLER trajectory (3DGP) is presented to minimize through-plane blurring without sacrificing perfusion sensitivity or increasing total scan time. Full brain perfusion images were acquired at a 3×3×5mm3 nominal voxel size with Q2TIPS-FAIR as the ASL preparation sequence. Data from 5 healthy subjects was acquired on a GE 1.5T scanner in less than 4 minutes per subject. While showing good agreement in CBF quantification with 3D GRASE, 3DGP demonstrated reduced through-plane blurring, improved anatomical details, high repeatability and robustness against motion, making it suitable for routine clinical use. PMID:21254211

  19. Assessment of vessel permeability by combining dynamic contrast-enhanced and arterial spin labeling MRI.

    Science.gov (United States)

    Liu, Ho-Ling; Chang, Ting-Ting; Yan, Feng-Xian; Li, Cheng-He; Lin, Yu-Shi; Wong, Alex M

    2015-06-01

    The forward volumetric transfer constant (K(trans)), a physiological parameter extracted from dynamic contrast-enhanced (DCE) MRI, is weighted by vessel permeability and tissue blood flow. The permeability × surface area product per unit mass of tissue (PS) in brain tumors was estimated in this study by combining the blood flow obtained through pseudo-continuous arterial spin labeling (PCASL) and K(trans) obtained through DCE MRI. An analytical analysis and a numerical simulation were conducted to understand how errors in the flow and K(trans) estimates would propagate to the resulting PS. Fourteen pediatric patients with brain tumors were scanned on a clinical 3-T MRI scanner. PCASL perfusion imaging was performed using a three-dimensional (3D) fast-spin-echo readout module to determine blood flow. DCE imaging was performed using a 3D spoiled gradient-echo sequence, and the K(trans) map was obtained with the extended Tofts model. The numerical analysis demonstrated that the uncertainty of PS was predominantly dependent on that of K(trans) and was relatively insensitive to the flow. The average PS values of the whole tumors ranged from 0.006 to 0.217 min(-1), with a mean of 0.050 min(-1) among the patients. The mean K(trans) value was 18% lower than the PS value, with a maximum discrepancy of 25%. When the parametric maps were compared on a voxel-by-voxel basis, the discrepancies between PS and K(trans) appeared to be heterogeneous within the tumors. The PS values could be more than two-fold higher than the K(trans) values for voxels with high K(trans) levels. This study proposes a method that is easy to implement in clinical practice and has the potential to improve the quantification of the microvascular properties of brain tumors.

  20. Quantitative perfusion imaging with pulsed arterial spin labeling. A phantom study

    International Nuclear Information System (INIS)

    Pulsed arterial spin labeling (PASL) is a magnetic resonance (MR) method for measuring cerebral blood flow. Although several validation studies for PASL in animals and humans have been reported, no reports have detailed the fundamental study of PASL using a flow phantom. We compared the true and theoretical flow rates in a flow phantom to confirm the analytical validity of quantitative perfusion imaging with Q2TIPS sequence. We built a flow phantom consisting of a 40-mm diameter plastic syringe filled with plastic beads and small plastic tubes 4 mm in diameter. Gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA)-doped 8L water solution (0.1 mM) was circulated between the syringe and a tank through a plastic tube by a constant flow pump while the flow rate was adjusted between 0 and 2.61 cm/s. Q2TIPS sequence parameters were TI1=50 ms and TI2=1400 ins. Five imaging slices of 50 subtraction images were acquired sequentially in a distal-to-proximal direction using a single-shot echo planar imaging (EPI) technique. The theoretical flow rate calculated based upon the previously reported kinetic model for Q2TIPS was compared with the true flow rate. A good linear relationship was observed between the theoretical, F', and true flow rates, F, in a flow rate range of 1.43 to 1.95 cm/s (F'=1.024·F-1.915, R2=0.902). The ratio of theoretical to true flow rate was 92 (+/-) 4%. Flow rate was quantified with reasonable accuracy when the entire amount of labeled bolus within the phantom could be recovered. Our experiment confirmed the analytical validity of Q2TIPS and suggested that blood flow measurement may be feasible using the Q2TIPS pulse sequence and kinetic model of the PASL equation. (author)

  1. Voxel-level comparison of arterial spin-labeled perfusion magnetic resonance imaging in adolescents with internet gaming addiction

    OpenAIRE

    Feng, Qi; Chen, Xue; Sun, Jinhua; Zhou, Yan; Sun, Yawen; Ding, Weina; Zhang, Yong; Zhuang, Zhiguo; Xu, Jianrong; Du, Yasong

    2013-01-01

    Background Although recent studies have clearly demonstrated functional and structural abnormalities in adolescents with internet gaming addiction (IGA), less is known about how IGA affects perfusion in the human brain. We used pseudocontinuous arterial spin-labeling (ASL) perfusion functional magnetic resonance imaging (fMRI) to measure the effects of IGA on resting brain functions by comparing resting cerebral blood flow in adolescents with IGA and normal subjects. Methods Fifteen adolescen...

  2. Chronic and treatment-resistant depression: a study using arterial spin labeling perfusion MRI at 3Tesla.

    OpenAIRE

    Duhameau, Bérengère; Ferré, Jean-Christophe; Jannin, Pierre; Gauvrit, Jean-Yves; Vérin, Marc; Millet, Bruno; Drapier, Dominique

    2010-01-01

    International audience The aim of the present study was to compare patients displaying chronic and treatment-resistant depression with healthy controls, using the resting-state perfusion with arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) technique at 3T. The study focused on the subgenual anterior cingulate cortex (sACC), which is a key component in the pathophysiology of depression. Six patients with chronic and treatment-resistant depression and six healthy cont...

  3. Multimodality evaluation of dural arteriovenous fistula with CT angiography, MR with arterial spin labeling, and digital subtraction angiography: case report.

    Science.gov (United States)

    Alexander, Matthew; McTaggart, Ryan; Santarelli, Justin; Fischbein, Nancy; Marks, Michael; Zaharchuk, Greg; Do, Huy

    2014-01-01

    Dural arteriovenous fistulae (DAVF) are cerebrovascular lesions with pathologic shunting into the venous system from arterial feeders. Digital subtraction angiography (DSA) has long been considered the gold standard for diagnosis, but advances in noninvasive imaging techniques now play a role in the diagnosis of these complex lesions. Herein, we describe the case of a patient with right-side pulsatile tinnitus and DAVF diagnosed using computed tomography angiography, magnetic resonance with arterial spin labeling, and DSA. Implications for imaging analysis of DAVFs and further research are discussed. PMID:23746119

  4. Prognostic value of blood flow measurements using arterial spin labeling in gliomas.

    Directory of Open Access Journals (Sweden)

    Julia Furtner

    Full Text Available The period of event-free survival (EFS within the same histopathological glioma grades may have high variability, mainly without a known cause. The purpose of this study was to reveal the prognostic value of quantified tumor blood flow (TBF values obtained by arterial spin labeling (ASL for EFS in patients with histopathologically proven astrocytomas independent of WHO (World Health Organization grade. Twenty-four patients with untreated gliomas underwent tumor perfusion quantification by means of pulsed ASL in 3T. The clinical history of the patients was retrospectively extracted from the local database. Six patients had to be excluded due to insufficent follow-up data for further evaluation or histopathologically verified oligodendroglioma tumor components. Receiver operating characteristic (ROC curves were used to define an optimal cut-off value of maximum TBF (mTBF values for subgrouping in low-perfused and high-perfused gliomas. Kaplan-Meier curves and Cox proportional hazard regression model were used to determine the prognostic value of mTBF for EFS. An optimal mTBF cut-off value of 182 ml/100 g/min (sensitivity  = 83%, specificity  = 100% was determined. Patients with low-perfused gliomas had significantly longer EFS compared to patients with high-perfused gliomas (p = 0.0012 independent of the WHO glioma grade. Quantified mTBF values obtained by ASL offer a new and totally non-invasive marker to prognosticate the EFS, independently on histopathological tumor grading, in patients with gliomas.

  5. Comparison of arterial spin labeling and dynamic susceptibility contrast perfusion MRI in patients with acute stroke.

    Directory of Open Access Journals (Sweden)

    Yen-Chu Huang

    Full Text Available BACKGROUND: The aim of this study was to evaluate whether arterial spin labeling (ASL perfusion magnetic resonance imaging (MRI can reliably quantify perfusion deficit as compared to dynamic susceptibility contrast (DSC perfusion MRI. METHODS: Thirty-nine patients with acute ischemic stroke in the anterior circulation territory were recruited. All underwent ASL and DSC MRI perfusion scans within 30 hours after stroke onset and 31 patients underwent follow-up MRI scans. ASL cerebral blood flow (CBF and DSC time to maximum (T(max maps were used to calculate the perfusion defects. The ASL CBF lesion volume was compared to the DSC Tmax lesion volume by Pearson's correlation coefficient and likewise the ASL CBF and DSC T(max lesion volumes were compared to the final infarct sizes respectively. A repeated measures analysis of variance and least significant difference post hoc test was used to compare the mean lesion volumes among ASL CBF, DSC T(max >4-6 s and final infarct. RESULTS: Mean patient age was 72.6 years. The average time from stroke onset to MRI was 13.9 hours. The ASL lesion volume showed significant correlation with the DSC lesion volume for T(max >4, 5 and 6 s (r = 0.81, 0.82 and 0.80; p5 s (29.2 ml, p6 s (21.8 ml, p5 or 6 s were close to mean final infarct size. CONCLUSION: Quantitative measurement of ASL perfusion is well correlated with DSC perfusion. However, ASL perfusion may overestimate the perfusion defects and therefore further refinement of the true penumbra threshold and improved ASL technique are necessary before applying ASL in therapeutic trials.

  6. Whole-brain perfusion imaging with balanced steady-state free precession arterial spin labeling.

    Science.gov (United States)

    Han, Paul Kyu; Ye, Jong Chul; Kim, Eung Yeop; Choi, Seung Hong; Park, Sung-Hong

    2016-03-01

    Recently, balanced steady-state free precession (bSSFP) readout has been proposed for arterial spin labeling (ASL) perfusion imaging to reduce susceptibility artifacts at a relatively high spatial resolution and signal-to-noise ratio (SNR). However, the main limitation of bSSFP-ASL is the low spatial coverage. In this work, methods to increase the spatial coverage of bSSFP-ASL are proposed for distortion-free, high-resolution, whole-brain perfusion imaging. Three strategies of (i) segmentation, (ii) compressed sensing (CS) and (iii) a hybrid approach combining the two methods were tested to increase the spatial coverage of pseudo-continuous ASL (pCASL) with three-dimensional bSSFP readout. The spatial coverage was increased by factors of two, four and six using each of the three approaches, whilst maintaining the same total scan time (5.3 min). The number of segments and/or CS acceleration rate (R) correspondingly increased to maintain the same bSSFP readout time (1.2 s). The segmentation approach allowed whole-brain perfusion imaging for pCASL-bSSFP with no penalty in SNR and/or total scan time. The CS approach increased the spatial coverage of pCASL-bSSFP whilst maintaining the temporal resolution, with minimal impact on the image quality. The hybrid approach provided compromised effects between the two methods. Balanced SSFP-based ASL allows the acquisition of perfusion images with wide spatial coverage, high spatial resolution and SNR, and reduced susceptibility artifacts, and thus may become a good choice for clinical and neurological studies. Copyright © 2015 John Wiley & Sons, Ltd.

  7. High accuracy of arterial spin labeling perfusion imaging in differentiation of pilomyxoid from pilocytic astrocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Nabavizadeh, S.A.; Assadsangabi, R.; Hajmomenian, M.; Vossough, A. [Perelman School of Medicine of the University of Pennsylvania, Department of Radiology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Santi, M. [Perelman School of Medicine of the University of Pennsylvania, Department of Pathology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States)

    2015-05-01

    Pilomyxoid astrocytoma (PMA) is a relatively new tumor entity which has been added to the 2007 WHO Classification of tumors of the central nervous system. The goal of this study is to utilize arterial spin labeling (ASL) perfusion imaging to differentiate PMA from pilocytic astrocytoma (PA). Pulsed ASL and conventional MRI sequences of patients with PMA and PA in the past 5 years were retrospectively evaluated. Patients with history of radiation or treatment with anti-angiogenic drugs were excluded. A total of 24 patients (9 PMA, 15 PA) were included. There were statistically significant differences between PMA and PA in mean tumor/gray matter (GM) cerebral blood flow (CBF) ratios (1.3 vs 0.4, p < 0.001) and maximum tumor/GM CBF ratio (2.3 vs 1, p < 0.001). Area under the receiver operating characteristic (ROC) curves for differentiation of PMA from PA was 0.91 using mean tumor CBF, 0.95 using mean tumor/GM CBF ratios, and 0.89 using maximum tumor/GM CBF. Using a threshold value of 0.91, the mean tumor/GM CBF ratio was able to diagnose PMA with 77 % sensitivity, 100 % specificity, and a threshold value of 0.7, provided 88 % sensitivity and 86 % specificity. There was no statistically significant difference between the two tumors in enhancement pattern (p = 0.33), internal architecture (p = 0.15), or apparent diffusion coefficient (ADC) values (p = 0.07). ASL imaging has high accuracy in differentiating PMA from PA. The result of this study may have important applications in prognostication and treatment planning especially in patients with less accessible tumors such as hypothalamic-chiasmatic gliomas. (orig.)

  8. Assessment of Alzheimer’s Disease Risk with Functional Magnetic Resonance Imaging: An Arterial Spin Labeling Study

    OpenAIRE

    Bangen, Katherine J.; Restom, Khaled; Liu, Thomas T.; Wierenga, Christina E.; Jak, Amy J.; Salmon, David P.; Bondi, Mark W.

    2012-01-01

    Functional magnetic resonance imaging (fMRI) of older adults at risk for Alzheimer’s disease (AD) by virtue of their cognitive (i.e., mild cognitive impairment [MCI]) and/or genetic (i.e., apolipoprotein E [APOE] ε4 allele) status demonstrate divergent brain response patterns during memory encoding across studies. Using arterial spin labeling MRI, we examined the influence of AD risk on resting cerebral blood flow (CBF) as well as the CBF and blood oxygenation level dependent (BOLD) signal re...

  9. Evaluation of tumor blood flow after feeder embolization in meningiomas by arterial spin-labeling perfusion magnetic resonance imaging.

    Science.gov (United States)

    Kawaji, Hiroshi; Koizumi, Shinichiro; Sakai, Naoto; Yamasaki, Tomohiro; Hiramatsu, Hisaya; Kanoko, Yusuke; Kamiya, Mika; Yamashita, Shuhei; Takehara, Yasuo; Sakahara, Harumi; Namba, Hiroki

    2013-10-01

    Preoperative embolization changes the amount of blood flow and pattern of flow distribution in meningioma. Tumor blood flow was investigated in eight meningioma patients before and after embolization using arterial spin-labeling (ASL) perfusion imaging. Although blood flow was significantly reduced in the whole tumor after embolization, changes in flow distribution patterns varied from one case to another. The findings suggest that evaluation of post-embolization tumor blood flow by ASL perfusion imaging would be useful in the surgical planning of meningioma.

  10. Improving quality of arterial spin labeling MR imaging at 3 Tesla with a 32-channel coil and parallel imaging.

    OpenAIRE

    Ferré, Jean-Christophe; Petr, Jan; Bannier, Elise; Barillot, Christian; Gauvrit, Jean-Yves

    2012-01-01

    PURPOSE: To compare 12-channel and 32-channel phased-array coils and to determine the optimal parallel imaging (PI) technique and factor for brain perfusion imaging using Pulsed Arterial Spin labeling (PASL) at 3 Tesla (T). MATERIALS AND METHODS: Twenty-seven healthy volunteers underwent 10 different PASL perfusion PICORE Q2TIPS scans at 3T using 12-channel and 32-channel coils without PI and with GRAPPA or mSENSE using factor 2. PI with factor 3 and 4 were used only with the 32-channel coil....

  11. Early-stage differentiation between presenile Alzheimer's disease and frontotemporal dementia using arterial spin labeling MRI

    Energy Technology Data Exchange (ETDEWEB)

    Steketee, Rebecca M.E.; Meijboom, Rozanna; Lugt, Aad van der; Smits, Marion [Erasmus MC - University Medical Center, Department of Radiology, PO Box 2040, Rotterdam (Netherlands); Bron, Esther E.; Klein, Stefan [Erasmus MC - University Medical Center, Biomedical Imaging Group Rotterdam, Departments of Medical Informatics and Radiology, PO Box 2040, Rotterdam (Netherlands); Houston, Gavin C. [GE Healthcare, Hatfield (United Kingdom); Mutsaerts, Henri J.M.M. [Academic Medical Center, Department of Radiology, PO Box 22660, Amsterdam (Netherlands); Mendez Orellana, Carolina P. [Erasmus MC - University Medical Center, Department of Radiology, PO Box 2040, Rotterdam (Netherlands); Erasmus MC - University Medical Center, Department of Neurology, PO Box 2040, Rotterdam (Netherlands); Jong, Frank Jan de; Swieten, John C. van [Erasmus MC - University Medical Center, Department of Neurology, PO Box 2040, Rotterdam (Netherlands)

    2016-01-15

    To investigate arterial spin labeling (ASL)-MRI for the early diagnosis of and differentiation between the two most common types of presenile dementia: Alzheimer's disease (AD) and frontotemporal dementia (FTD), and for distinguishing age-related from pathological perfusion changes. Thirteen AD and 19 FTD patients, and 25 age-matched older and 22 younger controls underwent 3D pseudo-continuous ASL-MRI at 3 T. Gray matter (GM) volume and cerebral blood flow (CBF), corrected for partial volume effects, were quantified in the entire supratentorial cortex and in 10 GM regions. Sensitivity, specificity and diagnostic performance were evaluated in regions showing significant CBF differences between patient groups or between patients and older controls. AD compared with FTD patients had hypoperfusion in the posterior cingulate cortex, differentiating these with a diagnostic performance of 74 %. Compared to older controls, FTD patients showed hypoperfusion in the anterior cingulate cortex, whereas AD patients showed a more widespread regional hypoperfusion as well as atrophy. Regional atrophy was not different between AD and FTD. Diagnostic performance of ASL to differentiate AD or FTD from controls was good (78-85 %). Older controls showed global hypoperfusion compared to young controls. ASL-MRI contributes to early diagnosis of and differentiation between presenile AD and FTD. (orig.)

  12. Voxel-Wise Functional Connectomics Using Arterial Spin Labeling Functional Magnetic Resonance Imaging: The Role of Denoising.

    Science.gov (United States)

    Liang, Xiaoyun; Connelly, Alan; Calamante, Fernando

    2015-11-01

    The objective of this study was to investigate voxel-wise functional connectomics using arterial spin labeling (ASL) functional magnetic resonance imaging (fMRI). Since ASL signal has an intrinsically low signal-to-noise ratio (SNR), the role of denoising is evaluated; in particular, a novel denoising method, dual-tree complex wavelet transform (DT-CWT) combined with the nonlocal means (NLM) algorithm is implemented and evaluated. Simulations were conducted to evaluate the performance of the proposed method in denoising images and in detecting functional networks from noisy data (including the accuracy and sensitivity of detection). In addition, denoising was applied to in vivo ASL datasets, followed by network analysis using graph theoretical approaches. Efficiencies cost was used to evaluate the performance of denoising in detecting functional networks from in vivo ASL fMRI data. Simulations showed that denoising is effective in detecting voxel-wise functional networks from low SNR data and/or from data with small total number of time points. The capability of denoised voxel-wise functional connectivity analysis was also demonstrated with in vivo data. We concluded that denoising is important for voxel-wise functional connectivity using ASL fMRI and that the proposed DT-CWT-NLM method should be a useful ASL preprocessing step.

  13. The effect of black tea and caffeine on regional cerebral blood flow measured with arterial spin labeling

    Science.gov (United States)

    Vidyasagar, Rishma; Greyling, Arno; Draijer, Richard; Corfield, Douglas R; Parkes, Laura M

    2013-01-01

    Black tea consumption has been shown to improve peripheral vascular function. Its effect on brain vasculature is unknown, though tea contains small amounts of caffeine, a psychoactive substance known to influence cerebral blood flow (CBF). We investigated the effects on CBF due to the intake of tea components in 20 healthy men in a double-blinded, randomized, placebo-controlled study. On separate days, subjects received a single dose of 184 mg caffeine (equivalent to one strong espresso coffee), 2,820 mg black tea solids containing 184 mg caffeine (equivalent to 6 cups of tea), 2,820 mg decaffeinated black tea solids, or placebo. The CBF and cerebrovascular reactivity (CVR) to hypercapnia were measured with arterial spin labeled magnetic resonance imaging (MRI) before and 2 hours after administration. We found a significant global reduction with caffeine (20%) and tea (21%) in gray matter CBF, with no effect of decaffeinated tea, suggesting that only caffeine influences CBF acutely. Voxelwise analysis revealed the effect of caffeine to be regionally specific. None of the interventions had an effect on CVR. Additional research is required to conclude on the physiologic relevance of these findings and the chronic effects of caffeine and tea intake on CBF. PMID:23486295

  14. Perfusion imaging of parotid gland tumours: usefulness of arterial spin labeling for differentiating Warthin's tumours

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroki; Watanabe, Haruo [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Kanematsu, Masayuki [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Kajita, Kimihiro [Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Mizuta, Keisuke; Aoki, Mitsuhiro [Gifu University School of Medicine, Department of Otolaryngology, Gifu (Japan); Okuaki, Tomoyuki [Philips Healthcare, Tokyo (Japan)

    2015-11-15

    To assess prospectively the efficacy of arterial spin labelling (ASL) against conventional and diffusion-weighted (DW) MR imaging for differentiating parotid gland tumours. We included 10 pleomorphic adenomas, 12 Warthin's tumours, and nine malignant tumours of the parotid glands. Only tumours larger than 10 mm were included in this study. All parotid gland tumours underwent T1-weighted, T2-weighted, DW, and ASL imaging. Tumour-to-parotid gland signal intensity ratios (SIRs) and apparent diffusion coefficients (ADCs) of solid components were correlated with these pathologies. SIRs on T2-weighted images and ADCs were higher in pleomorphic adenomas than in Warthin's tumours (p <.01) and malignant tumours (p <.01). SIRs on ASL were higher in Warthin's tumours than in pleomorphic adenomas (p <.01) and malignant tumours (p <.05). Az value of SIRs on ASL for differentiating Warthin's tumours from the other pathologies was 0.982. The sensitivity, specificity, and accuracy of SIRs on ASL for the diagnosis of Warthin's tumours at an optimal SIR threshold of over 8.70 were 91.7 %, 94.7 %, and 93.5 %, respectively. ASL with SIR measurements could non-invasively evaluate tumour blood flow of parotid gland tumours and differentiate Warthin's tumours from pleomorphic adenomas and malignant tumours. (orig.)

  15. Early-stage differentiation between presenile Alzheimer's disease and frontotemporal dementia using arterial spin labeling MRI

    International Nuclear Information System (INIS)

    To investigate arterial spin labeling (ASL)-MRI for the early diagnosis of and differentiation between the two most common types of presenile dementia: Alzheimer's disease (AD) and frontotemporal dementia (FTD), and for distinguishing age-related from pathological perfusion changes. Thirteen AD and 19 FTD patients, and 25 age-matched older and 22 younger controls underwent 3D pseudo-continuous ASL-MRI at 3 T. Gray matter (GM) volume and cerebral blood flow (CBF), corrected for partial volume effects, were quantified in the entire supratentorial cortex and in 10 GM regions. Sensitivity, specificity and diagnostic performance were evaluated in regions showing significant CBF differences between patient groups or between patients and older controls. AD compared with FTD patients had hypoperfusion in the posterior cingulate cortex, differentiating these with a diagnostic performance of 74 %. Compared to older controls, FTD patients showed hypoperfusion in the anterior cingulate cortex, whereas AD patients showed a more widespread regional hypoperfusion as well as atrophy. Regional atrophy was not different between AD and FTD. Diagnostic performance of ASL to differentiate AD or FTD from controls was good (78-85 %). Older controls showed global hypoperfusion compared to young controls. ASL-MRI contributes to early diagnosis of and differentiation between presenile AD and FTD. (orig.)

  16. The effect of black tea and caffeine on regional cerebral blood flow measured with arterial spin labeling.

    Science.gov (United States)

    Vidyasagar, Rishma; Greyling, Arno; Draijer, Richard; Corfield, Douglas R; Parkes, Laura M

    2013-06-01

    Black tea consumption has been shown to improve peripheral vascular function. Its effect on brain vasculature is unknown, though tea contains small amounts of caffeine, a psychoactive substance known to influence cerebral blood flow (CBF). We investigated the effects on CBF due to the intake of tea components in 20 healthy men in a double-blinded, randomized, placebo-controlled study. On separate days, subjects received a single dose of 184 mg caffeine (equivalent to one strong espresso coffee), 2,820 mg black tea solids containing 184 mg caffeine (equivalent to 6 cups of tea), 2,820 mg decaffeinated black tea solids, or placebo. The CBF and cerebrovascular reactivity (CVR) to hypercapnia were measured with arterial spin labeled magnetic resonance imaging (MRI) before and 2 hours after administration. We found a significant global reduction with caffeine (20%) and tea (21%) in gray matter CBF, with no effect of decaffeinated tea, suggesting that only caffeine influences CBF acutely. Voxelwise analysis revealed the effect of caffeine to be regionally specific. None of the interventions had an effect on CVR. Additional research is required to conclude on the physiologic relevance of these findings and the chronic effects of caffeine and tea intake on CBF.

  17. Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla

    OpenAIRE

    Gillis, Keith A.; McComb, Christie; Foster, John E.; Taylor, Alison; Patel, Rajan K.; Morris, Scott; Alan G. Jardine; Schneider, Markus P; Roditi, Giles H; Delles, Christian; Mark, Patrick B.

    2014-01-01

    Background: Measurement of renal perfusion is a crucial part of measuring kidney function. Arterial spin labelling magnetic resonance imaging (ASL MRI) is a non-invasive method of measuring renal perfusion using magnetised blood as endogenous contrast. We studied the reproducibility of ASL MRI in normal volunteers. Methods: ASL MRI was performed in healthy volunteers on 2 occasions using a 3.0 Tesla MRI scanner with flow-sensitive alternating inversion recovery (FAIR) perfusion prep...

  18. Brain perfusion in dementia with Lewy bodies and Alzheimer’s disease: an arterial spin labeling MRI study on prodromal and mild dementia stages

    OpenAIRE

    Roquet, Daniel; Sourty, Marion; Botzung, Anne; Armspach, Jean-Paul; Blanc, Frédéric

    2016-01-01

    Background We aimed to describe specific changes in brain perfusion in patients with dementia with Lewy bodies (DLB) at both the prodromal (also called mild cognitive impairment) and mild dementia stages, relative to patients with Alzheimer’s disease (AD) and controls. Methods Altogether, 96 participants in five groups (prodromal DLB, prodromal AD, DLB with mild dementia, AD with mild dementia, and healthy elderly controls) took part in an arterial spin labeling MRI study. Three analyses were...

  19. Evaluation of Intracranial Vasculatures in Healthy Subjects with Arterial-Spin-Labeling-Based 4D-MR Angiography at 3T.

    Science.gov (United States)

    Iryo, Yasuhiko; Hirai, Toshinori; Nakamura, Masanobu; Tateishi, Machiko; Hayashida, Eri; Azuma, Minako; Nishimura, Shinichiro; Kitajima, Mika; Yamashita, Yasuyuki

    2016-07-11

    Contrast inherent inflow-enhanced multi-phase angiography combining multiple-phase flow-alternating inversion-recovery (CINEMA-FAIR) is an arterial-spin-labeling-based four-dimensional magnetic resonance angiography (4D-MRA) technique. Two neuroradiologists independently evaluated the depiction of the intracranial vasculatures in healthy subjects with 3T 4D-MRA using CINEMA-FAIR. Our results indicated that this technique can provide good visualization of the cerebral arteries with a high spatial and temporal resolution. It appears to have sufficient resolution for identifying flow difference in the anterior and posterior circulation in healthy subjects. PMID:26701696

  20. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier;

    2010-01-01

    Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated...

  1. Early response assessment in patients with multiple myeloma during anti-angiogenic therapy using arterial spin labelling: first clinical results

    International Nuclear Information System (INIS)

    To determine if arterial-spin-labelling (ASL) MRI can reliably detect early response to anti-angiogenic therapy in patients with multiple myeloma by comparison with clinical/haematological response. Nineteen consecutive patients (10 men; mean age 63.5 ± 9.1 years) were included in the present study. Inclusion criteria were diagnosis of stage III multiple myeloma and clinical indication for therapeutical administration of bortezomib or lenalidomide. We performed MRI on 3.0T MR in the baseline setting, 3 weeks after onset of therapy and after 8 weeks. Clinical responses were determined on the basis of international uniform response criteria in correlation with haematological parameters and medium-term patient outcome. MRI studies were performed after approval by the local institutional review board. Fifteen patients responded to anti-myeloma therapy; 4/19 patients were non-responders to therapy. Mean tumour perfusion assessed by ASL-MRI in a reference lesion was 220.7 ± 132.5 ml min-1 100 g-1 at baseline, and decreased to 125.7 ± 86.3 (134.5 ± 150.9) ml min-1 100 g-1 3 (8) weeks after onset of therapy (P < 0.02). The mean decrease in paraproteinaemia at week 3 (8) was 52.3 ± 47.7% (58.2 ± 58.7%), whereas β2-microglobulinaemia decreased by 20.3 ± 53.1% (23.3 ± 57.0%). Correlation of ASL perfusion with outcome was significant (P = 0.0037). ASL tumour perfusion measurements are a valuable surrogate parameter for early assessment of response to novel anti-angiogenic therapy. (orig.)

  2. Early response assessment in patients with multiple myeloma during anti-angiogenic therapy using arterial spin labelling: first clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Fenchel, Michael [Eberhard-Karls University, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Eberhard-Karls University, Department of Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Konaktchieva, Marina [Eberhard-Karls University, Department of Internal Medicine, Gastroenterology, Tuebingen (Germany); Weisel, Katja; Kraus, Sabina [Eberhard-Karls University, Department of Internal Medicine, Hematology, Tuebingen (Germany); Brodoefel, Harald; Claussen, Claus D.; Horger, Marius [Eberhard-Karls University, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2010-12-15

    To determine if arterial-spin-labelling (ASL) MRI can reliably detect early response to anti-angiogenic therapy in patients with multiple myeloma by comparison with clinical/haematological response. Nineteen consecutive patients (10 men; mean age 63.5 {+-} 9.1 years) were included in the present study. Inclusion criteria were diagnosis of stage III multiple myeloma and clinical indication for therapeutical administration of bortezomib or lenalidomide. We performed MRI on 3.0T MR in the baseline setting, 3 weeks after onset of therapy and after 8 weeks. Clinical responses were determined on the basis of international uniform response criteria in correlation with haematological parameters and medium-term patient outcome. MRI studies were performed after approval by the local institutional review board. Fifteen patients responded to anti-myeloma therapy; 4/19 patients were non-responders to therapy. Mean tumour perfusion assessed by ASL-MRI in a reference lesion was 220.7 {+-} 132.5 ml min{sup -1} 100 g{sup -1} at baseline, and decreased to 125.7 {+-} 86.3 (134.5 {+-} 150.9) ml min{sup -1} 100 g{sup -1} 3 (8) weeks after onset of therapy (P < 0.02). The mean decrease in paraproteinaemia at week 3 (8) was 52.3 {+-} 47.7% (58.2 {+-} 58.7%), whereas {beta}2-microglobulinaemia decreased by 20.3 {+-} 53.1% (23.3 {+-} 57.0%). Correlation of ASL perfusion with outcome was significant (P = 0.0037). ASL tumour perfusion measurements are a valuable surrogate parameter for early assessment of response to novel anti-angiogenic therapy. (orig.)

  3. Cerebral blood flow changes in hemodialysis and peritoneal dialysis patients: an arterial-spin labeling MR imaging.

    Science.gov (United States)

    Jiang, Xiao Lu; Wen, Ji Qiu; Zhang, Long Jiang; Zheng, Gang; Li, Xue; Zhang, Zhe; Liu, Ya; Zheng, Li Juan; Wu, Long; Chen, Hui Juan; Kong, Xiang; Luo, Song; Lu, Guang Ming; Ji, Xue Man; Zhang, Zong Jun

    2016-08-01

    We used arterial-spin labeling (ASL) MR imaging, a non-invasive technique to evaluate cerebral blood flow (CBF) changes in patients with end-stage renal disease (ESRD) undergoing peritoneal dialysis (PD) and hemodialysis (HD), and nondialysis ESRD patients compared with healthy cohort. Ninety seven ESRD patients including 32 PD patients (20 male, 12 female; mean age 33 ± 8 years), 33 HD patients (22 male, 11 female; mean age 33 ± 8 years) and 32 nondialysis patients (20 male, 12 female; mean age 35 ± 7 years) and 31 age- and gender-matched healthy controls (20 male, 11 female; mean age 32 ± 8 years) were included in this study. All subjects underwent ASL MR imaging, neuropsychologic tests, and ESRD patients underwent laboratory testing. CBF values were compared among PD, HD, nondialysis patients and control groups. Correlation analysis and multiple regression analysis were performed to investigate the association between CBF values and hemoglobin, neuropsychologic test results, serum creatinine, urea levels, disease duration, and dialysis duration. Elevated CBFs of whole brain region, gray matter, and white matter were found in all ESRD patient groups compared with healthy controls (all P differences for CBF between PD and HD patient groups. Negative correlations were observed between mean CBFs of whole brain region, gray matter, and white matter and the hemoglobin level in all ESRD patients. Multiple linear regression showed elevated CBF of multiple brain areas correlated with some neuropsychological tests in ESRD patients (all P differences of CBF change and cognitive function between PD and HD ESRD patients with long-term treatment. The degree of anemia may be a predominant risk factor for cognitive impairment in these ESRD patients. PMID:27167984

  4. Temporal and extra-temporal hypoperfusion in medial temporal lobe epilepsy evaluated by arterial-spin-labeling based MRI

    International Nuclear Information System (INIS)

    Objective: To evaluate the feasibility of the lateralization of unilateral medial temporal lobe epilepsy (mTLE) by using arterial-spin-labeling (ASL) based perfusion MR imaging and investigate the changes of perfusion in the regions related to mTLE network and the relationship between the perfusion and the clinical status. Methods: Twenty-five patients with left-sided and 23 with right-sided mTLE were enrolled, and 30 healthy volunteers were recruited. The cerebral blood flow (CBF) of related region was measured based on pulsed-ASL sequence on Siemens 3 T scanner. The CBF of the mTLE group were compared with that in the controls by using ANOVA analysis. The asymmetric indices of CBF in the medial temporal lobe were calculated as the lesion side compared with the normal side in matched region in mTLE group. Results: Compared with the volunteers, the patients with mTLE showed the decrease of CBF in the bilateral medial and lateral temporal, the frontal and parietal regions relating to the default-mode network and more serious in lesion side. The CBF values of the medial temporal lobe were negatively correlated with the epilepsy duration (r=-0.51, P<0.01). The asymmetric index of CBF as-0.01 has a 76.0% (19/25) sensitivity and a 78.3% (18/23) specificity to distinguish the lesion side. Conclusions: The decrease of CBF in the temporal and extra-temporal region by ASL-based MRI suggests the functional abnormalities in the network involved by mTLE. The ASL technique is a useful tool for lateralizing the unilateral mTLE. (authors)

  5. Arterial spin labelling MRI for assessment of cerebral perfusion in children with moyamoya disease: comparison with dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Goetti, Robert [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland); University Hospital Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); O' Gorman, Ruth [University Children' s Hospital Zurich, Center for MR Research, Zurich (Switzerland); Khan, Nadia [University Children' s Hospital Zurich, Moyamoya Center, Division of Neurosurgery, Department of Surgery, Zurich (Switzerland); Kellenberger, Christian J.; Scheer, Ianina [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland)

    2013-05-15

    This study seeks to evaluate the diagnostic accuracy of cerebral perfusion imaging with arterial spin labelling (ASL) MR imaging in children with moyamoya disease compared to dynamic susceptibility contrast (DSC) imaging. Ten children (7 females; age, 9.2 {+-} 5.4 years) with moyamoya disease underwent cerebral perfusion imaging with ASL and DSC on a 3-T MRI scanner in the same session. Cerebral perfusion images were acquired with ASL (pulsed continuous 3D ASL sequence, 32 axial slices, TR = 5.5 s, TE = 25 ms, FOV = 24 cm, matrix = 128 x 128) and DSC (gradient echo EPI sequence, 35 volumes of 28 axial slices, TR = 2,000 ms, TE = 36 ms, FOV = 24 cm, matrix = 96 x 96, 0.2 ml/kg Gd-DOTA). Cerebral blood flow maps were generated. ASL and DSC images were qualitatively assessed regarding perfusion of left and right ACA, MCA, and PCA territories by two independent readers using a 3-point-Likert scale and quantitative relative cerebral blood flow (rCBF) was calculated. Correlation between ASL and DSC for qualitative and quantitative assessment and the accuracy of ASL for the detection of reduced perfusion per territory with DSC serving as the standard of reference were calculated. With a good interreader agreement ({kappa} = 0.62) qualitative perfusion assessment with ASL and DSC showed a strong and significant correlation ({rho} = 0.77; p < 0.001), as did quantitative rCBF (r = 0.79; p < 0.001). ASL showed a sensitivity, specificity and accuracy of 94 %, 93 %, and 93 % for the detection of reduced perfusion per territory. In children with moyamoya disease, unenhanced ASL enables the detection of reduced perfusion per vascular territory with a good accuracy compared to contrast-enhanced DSC. (orig.)

  6. The Cerebral Blood Flow Biomedical Informatics Research Network (CBFBIRN) database and analysis pipeline for arterial spin labeling MRI data.

    Science.gov (United States)

    Shin, David D; Ozyurt, I Burak; Liu, Thomas T

    2013-01-01

    Arterial spin labeling (ASL) is a magnetic resonance imaging technique that provides a non-invasive and quantitative measure of cerebral blood flow (CBF). After more than a decade of active research, ASL is now emerging as a robust and reliable CBF measurement technique with increased availability and ease of use. There is a growing number of research and clinical sites using ASL for neuroscience research and clinical care. In this paper, we present an online CBF Database and Analysis Pipeline, collectively called the Cerebral Blood Flow Biomedical Informatics Research Network (CBFBIRN) that allows researchers to upload and share ASL and clinical data. In addition to serving the role as a central data repository, the CBFBIRN provides a streamlined data processing infrastructure for CBF quantification and group analysis, which has the potential to accelerate the discovery of new scientific and clinical knowledge. All capabilities and features built into the CBFBIRN are accessed online using a web browser through a secure login. In this work, we begin with a general description of the CBFBIRN system data model and its architecture, then devote the remainder of the paper to the CBFBIRN capabilities. The latter part of our work is divided into two processing modules: (1) Data Upload and CBF Quantification Module; (2) Group Analysis Module that supports three types of analysis commonly used in neuroscience research. To date, the CBFBIRN hosts CBF maps and associated clinical data from more than 1,300 individual subjects. The data have been contributed by more than 20 different research studies, investigating the effect of various conditions on CBF including Alzheimer's, schizophrenia, bipolar disorder, depression, traumatic brain injury, HIV, caffeine usage, and methamphetamine abuse. Several example results, generated by the CBFBIRN processing modules, are presented. We conclude with the lessons learned during implementation and deployment of the CBFBIRN and our

  7. The Cerebral Blood Flow Biomedical Informatics Research Network (CBFBIRN Database and Analysis Pipeline for Arterial Spin Labeling MRI Data

    Directory of Open Access Journals (Sweden)

    David D. Shin

    2013-10-01

    Full Text Available Arterial spin labeling (ASL is a MRI technique that provides a noninvasive and quantitative measure of cerebral blood flow (CBF. After more than a decade of active research, ASL is now emerging as a robust and reliable CBF measurement technique with increased availability and ease of use. There is a growing number of research and clinical sites using ASL for neuroscience research and clinical care. In this paper, we present an online CBF Database and Analysis Pipeline, collectively called the CBFBIRN that allows researchers to upload and share ASL and clinical data. In addition to serving the role as a central data repository, the CBFBIRN provides a streamlined data processing infrastructure for CBF quantification and group analysis, which has the potential to accelerate the discovery of new scientific and clinical knowledge. All capabilities and features built into the CBFBIRN are accessed online using a web browser through a secure login. In this work, we begin with a general description of the CBFBIRN system data model and its architecture, then devote the remainder of the paper to the CBFBIRN capabilities. The latter part of our work is divided into two processing modules: 1 Data Upload and CBF Quantification Module; 2 Group Analysis Module that supports three types of analysis commonly used in neuroscience research. To date, the CBFBIRN hosts CBF maps and associated clinical data from more than 1300 individual subjects. The data have been contributed by more than 20 different research studies, investigating the effect of various conditions on CBF including Alzheimer’s, schizophrenia, bipolar disorder, depression, traumatic brain injury, HIV, caffeine usage and Methamphetamine abuse. Several example results, generated by the CBFBIRN processing modules, are presented. We conclude with the lessons learned during implementation and deployment of the CBFBIRN and our experience in promoting data sharing.

  8. Feasibility of Using Pseudo-Continuous Arterial Spin Labeling Perfusion in a Geriatric Population at 1.5 Tesla.

    Directory of Open Access Journals (Sweden)

    Sigurdur Sigurdsson

    Full Text Available To evaluate the feasibility of using pseudo-continuous arterial spin labeling (pCASL perfusion in a geriatric population at 1.5-Tesla.In 17 participants (mean age 78.8±1.63 years we assessed; 1 inter-session repeatability and reliability of resting state perfusion in 27 brain regions; 2 brain activation using finger-tapping as a means to evaluate the ability to detect flow differences; 3 reliability by comparing cerebral blood flow (CBF with pCASL to CBF with phase contrast (PC-MR.The CBF (mean±standard deviation (SD for the whole brain grey matter (GM was 40.6±8.4 and 41.4±8.7 ml/100g/min for the first and second scan respectively. The within-subject standard deviation (SDw, the repeatability index (RI and intra-class correlation coefficient (ICC across the 27 regions ranged from 1.1 to 7.9, 2.2 to 15.5 and 0.35 to 0.98 respectively. For whole brain GM the SDw, RI and ICC were 1.6, 3.2 and 0.96 respectively. The between-subject standard deviation (SDB was larger than the SDw for all regions. Comparison of CBF at rest and activation on a voxel level showed significantly higher perfusion during finger tapping in the motor- and somatosensory regions. The mean CBF for whole brain GM was 40.6±8.4 ml/100g/min at rest and 42.6±8.6 ml/100g/min during activation. Finally the reliability of pCASL against the reference standard of PC-MR was high (ICC = 0.80. The mean CBF for whole brain measured with PC-MRI was 54.3±10.1 ml/100g/min and 38.3±7.8 ml/100g/min with pCASL.The results demonstrate moderate to high levels of repeatability and reliability for most brain regions, comparable to what has been reported for younger populations. The performance of pCASL at 1.5-Tesla shows that region-specific perfusion measurements with this technique are feasible in studies of a geriatric population.

  9. [Abnormal cerebral blood flow distributions during the post-ictal phase of febrile status epilepticus in three pediatric patients measured by arterial spin labeling perfusion MRI].

    Science.gov (United States)

    Hirano, Keiko; Fukuda, Tokiko

    2016-05-01

    The ability to visualize brain perfusion is important for identifying epileptic foci. We present three pediatric cases showing asymmetrical cerebral blood flow (CBF) distributions during the post-ictal phase of febrile status epilepticus measured by arterial spin labeling (ASL) perfusion MRI. During the acute phase, regional CBF measurements in the areas considered including epileptic foci were higher than in the corresponding area of the contralateral hemisphere, though the exact quantitative value varied between cases. We could not identify the correct epileptogenic foci, because those ASL images were taken after the prolonged and extraordinary activation of neurons in the affected area. During the recovery phase, the differences reduced and the average regional CBF measurement was 54.6 ± 6.1 ml/100 g per minute, which was a little less than the number of previous ASL studies. ASL perfusion MRI imaging provides a method for evaluating regional CBF by using magnetically labeled arterial blood water as an endogenous tracer. With this technique, we can repeatedly evaluate both the brain structure and the level of perfusion at the same time. ASL is noninvasive and easily accessible, and therefore it could become a routine tool for assessment of perfusion in daily practice of pediatric neurology.

  10. Multi-delay arterial spin labeling perfusion MRI in moyamoya disease-comparison with CT perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Rui [Chinese Academy of Sciences, State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Beijing (China); University of Chinese Academy of Sciences, Graduate School, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Los Angeles, CA (United States); Yu, Songlin [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); University of California Los Angeles, Department of Neurology, Los Angeles (United States); Alger, Jeffry R.; Wang, Danny J.J. [University of California Los Angeles, Department of Neurology, Los Angeles (United States); UCLA-Beijing Joint Center for Advanced Brain Imaging, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Los Angeles, CA (United States); Zuo, Zhentao; Wang, Bo [Chinese Academy of Sciences, State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Beijing (China); Chen, Juan [Beijing Hospital, Department of Radiology, Beijing (China); Wang, Rong; Zhao, Jizong [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); An, Jing [Siemens Shenzhen Magnetic Resonance Ltd, Shenzhen (China); Xue, Rong [Chinese Academy of Sciences, State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Los Angeles, CA (United States)

    2014-05-15

    To present a multi-delay pseudo-continuous ASL (pCASL) protocol that offers simultaneous measurements of cerebral blood flow (CBF) and arterial transit time (ATT), and to study correlations between multi-delay pCASL and CT perfusion in moyamoya disease. A 4 post-labeling delay (PLD) pCASL protocol was applied on 17 patients with moyamoya disease who also underwent CT perfusion imaging. ATT was estimated using the multi-delay protocol and included in the calculation of CBF. ASL and CT perfusion images were rated for lesion severity/conspicuity. Pearson correlation coefficients were calculated across voxels between the two modalities in grey and white matter of each subject respectively and between normalized mean values of ASL and CT perfusion measures in major vascular territories. Significant associations between ASL and CT perfusion were detected using subjective ratings, voxel-wise analysis in grey and white matter and region of interest (ROI)-based analysis of normalized mean perfusion. The correlation between ASL CBF and CT perfusion was improved using the multi-delay pCASL protocol compared to CBF acquired at a single PLD of 2 s (P < 0.05). There is a correlation between perfusion data from ASL and CT perfusion imaging in patients with moyamoya disease. Multi-delay ASL can improve CBF quantification, which could be a prognostic imaging biomarker in patients with moyamoya disease. (orig.)

  11. Regional and voxel-wise comparisons of blood flow measurements between dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) and arterial spin labeling (ASL) in brain tumors.

    Science.gov (United States)

    White, Carissa M; Pope, Whitney B; Zaw, Taryar; Qiao, Joe; Naeini, Kourosh M; Lai, Albert; Nghiemphu, Phioanh L; Wang, J J; Cloughesy, Timothy F; Ellingson, Benjamin M

    2014-01-01

    The objective of the current study was to evaluate the regional and voxel-wise correlation between dynamic susceptibility contrast (DSC) and arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) measurement of cerebral blood flow (CBF) in patients with brain tumors. Thirty patients with histologically verified brain tumors were evaluated in the current study. DSC-MRI was performed by first using a preload dose of gadolinium contrast, then collecting a dynamic image acquisition during a bolus of contrast, followed by posthoc contrast agent leakage correction. Pseudocontinuous ASL was collected using 30 pairs of tag and control acquisition using a 3-dimensional gradient-echo spin-echo (GRASE) acquisition. All images were registered to a high-resolution anatomical atlas. Average CBF measurements within regions of contrast-enhancement and T2 hyperintensity were evaluated between the two modalities. Additionally, voxel-wise correlation between CBF measurements obtained with DSC and ASL were assessed. Results demonstrated a positive linear correlation between DSC and ASL measurements of CBF when regional average values were compared; however, a statistically significant voxel-wise correlation was only observed in around 30-40% of patients. These results suggest DSC and ASL may provide regionally similar, but spatially different measurements of CBF.

  12. Renal blood flow using arterial spin labelling MRI and calculated filtration fraction in healthy adult kidney donors pre-nephrectomy and post-nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Cutajar, Marica; Clark, Christopher A.; Gordon, Isky [University College London, Imaging and Biophysics Unit, Institute of Child Health, London (United Kingdom); Hilton, Rachel; Olsburgh, Jonathon [Renal Unit, Guy' s and St Thomas' NHS Foundation Trust, London (United Kingdom); Marks, Stephen D. [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Paediatric Nephrology, London (United Kingdom); Thomas, David L. [University College London, Department of Brain Repair and Rehabilitation, Institute of Neurology, London (United Kingdom); Banks, Tina [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Radiology, London (United Kingdom)

    2015-08-15

    Renal plasma flow (RPF) (derived from renal blood flow, RBF) and glomerular filtration rate (GFR) allow the determination of the filtration fraction (FF), which may have a role as a non-invasive renal biomarker. This is a hypothesis-generating pilot study assessing the effect of nephrectomy on renal function in healthy kidney donors. Eight living kidney donors underwent arterial spin labelling (ASL) magnetic resonance imaging (MRI) and GFR measurement prior to and 1 year after nephrectomy. Chromium-51 labelled ethylenediamine tetraacetic acid ({sup 51}Cr-EDTA) with multi-blood sampling was undertaken and GFR calculated. The RBF and GFR obtained were used to calculate FF. All donors showed an increase in single kidney GFR of 24 - 75 %, and all but two showed an increase in FF (-7 to +52 %) after nephrectomy. The increase in RBF, and hence RPF, post-nephrectomy was not as great as the increase in GFR in seven out of eight donors. As with any pilot study, the small number of donors and their relatively narrow age range are potential limiting factors. The ability to measure RBF, and hence RPF, non-invasively, coupled with GFR measurement, allows calculation of FF, a biomarker that might provide a sensitive indicator of loss of renal reserve in potential donors. (orig.)

  13. Renal blood flow using arterial spin labelling MRI and calculated filtration fraction in healthy adult kidney donors pre-nephrectomy and post-nephrectomy

    International Nuclear Information System (INIS)

    Renal plasma flow (RPF) (derived from renal blood flow, RBF) and glomerular filtration rate (GFR) allow the determination of the filtration fraction (FF), which may have a role as a non-invasive renal biomarker. This is a hypothesis-generating pilot study assessing the effect of nephrectomy on renal function in healthy kidney donors. Eight living kidney donors underwent arterial spin labelling (ASL) magnetic resonance imaging (MRI) and GFR measurement prior to and 1 year after nephrectomy. Chromium-51 labelled ethylenediamine tetraacetic acid (51Cr-EDTA) with multi-blood sampling was undertaken and GFR calculated. The RBF and GFR obtained were used to calculate FF. All donors showed an increase in single kidney GFR of 24 - 75 %, and all but two showed an increase in FF (-7 to +52 %) after nephrectomy. The increase in RBF, and hence RPF, post-nephrectomy was not as great as the increase in GFR in seven out of eight donors. As with any pilot study, the small number of donors and their relatively narrow age range are potential limiting factors. The ability to measure RBF, and hence RPF, non-invasively, coupled with GFR measurement, allows calculation of FF, a biomarker that might provide a sensitive indicator of loss of renal reserve in potential donors. (orig.)

  14. Pattern of cerebral hyperperfusion in Alzheimer's disease and amnestic mild cognitive impairment using voxel-based analysis of 3D arterial spin-labeling imaging: initial experience

    Directory of Open Access Journals (Sweden)

    Ding B

    2014-03-01

    Full Text Available Bei Ding,1 Hua-wei Ling,1 Yong Zhang,2 Juan Huang,1 Huan Zhang,1 Tao Wang,3 Fu Hua Yan11Department of Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, 2Applied Science Laboratory, GE Healthcare, 3Department of Gerontology, Shanghai Mental Health Center, Shanghai, People's Republic of ChinaPurpose: A three-dimensional (3D continuous pulse arterial spin labeling (ASL technique was used to investigate cerebral blood flow (CBF changes in patients with Alzheimer's disease (AD, amnestic mild cognitive impairment (aMCI, and age- and sex-matched healthy controls.Materials and methods: Three groups were recruited for comparison, 24 AD patients, 17 MCI patients, and 21 age- and sex-matched control subjects. Three-dimensional ASL scans covering the entire brain were acquired with a 3.0 T magnetic resonance scanner. Spatial processing was performed with statistical parametric mapping 8. A second-level one-way analysis of variance analysis (threshold at P<0.05 was performed on the preprocessed ASL data. An average whole-brain CBF for each subject was also included as group-level covariates for the perfusion data, to control for individual CBF variations.Results: Significantly increased CBF was detected in bilateral frontal lobes and right temporal subgyral regions in aMCI compared with controls. When comparing AD with aMCI, the major hyperperfusion regions were the right limbic lobe and basal ganglia regions, including the putamen, caudate, lentiform nucleus, and thalamus, and hypoperfusion was found in the left medial frontal lobe, parietal cortex, the right middle temporo-occipital lobe, and particularly, the left anterior cingulate gyrus. We also found decreased CBF in the bilateral temporo-parieto-occipital cortices and left limbic lobe in AD patients, relative to the control group. aMCI subjects showed decreased blood flow in the left occipital lobe, bilateral inferior temporal cortex, and right middle temporal cortex

  15. Arterial spin labeling-fast imaging with steady-state free precession (ASL-FISP): a rapid and quantitative perfusion technique for high-field MRI.

    Science.gov (United States)

    Gao, Ying; Goodnough, Candida L; Erokwu, Bernadette O; Farr, George W; Darrah, Rebecca; Lu, Lan; Dell, Katherine M; Yu, Xin; Flask, Chris A

    2014-08-01

    Arterial spin labeling (ASL) is a valuable non-contrast perfusion MRI technique with numerous clinical applications. Many previous ASL MRI studies have utilized either echo-planar imaging (EPI) or true fast imaging with steady-state free precession (true FISP) readouts, which are prone to off-resonance artifacts on high-field MRI scanners. We have developed a rapid ASL-FISP MRI acquisition for high-field preclinical MRI scanners providing perfusion-weighted images with little or no artifacts in less than 2 s. In this initial implementation, a flow-sensitive alternating inversion recovery (FAIR) ASL preparation was combined with a rapid, centrically encoded FISP readout. Validation studies on healthy C57/BL6 mice provided consistent estimation of in vivo mouse brain perfusion at 7 and 9.4 T (249 ± 38 and 241 ± 17 mL/min/100 g, respectively). The utility of this method was further demonstrated in the detection of significant perfusion deficits in a C57/BL6 mouse model of ischemic stroke. Reasonable kidney perfusion estimates were also obtained for a healthy C57/BL6 mouse exhibiting differential perfusion in the renal cortex and medulla. Overall, the ASL-FISP technique provides a rapid and quantitative in vivo assessment of tissue perfusion for high-field MRI scanners with minimal image artifacts.

  16. Evaluation of the degree of arteriovenous shunting in intracranial arteriovenous malformations using pseudo-continuous arterial spin labeling magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sunwoo, Leonard; Park, Sun-Won [Seoul Metropolitan Government - Seoul National University Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Sohn, Chul-Ho; Yun, Tae Jin; Choi, Seung Hong; Cho, Young Dae; Kim, Ji-hoon; Han, Moon Hee [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Lee, Jong Young [Kangdong Sacred Heart Hospital, Department of Neurosurgery, Seoul (Korea, Republic of); Yi, Kyung Sik [Chungbuk National University Hospital, Department of Radiology, Cheongju (Korea, Republic of); Paek, Sun Ha; Kim, Yong Hwy; Kim, Jin Wook; Chung, Hyun-Tai; Kim, Dong Gyu [Seoul National University Hospital, Department of Neurosurgery, Seoul (Korea, Republic of)

    2015-08-15

    Intracranial arteriovenous malformations (AVMs) display venous signals on arterial spin labeling (ASL) magnetic resonance (MR) imaging due to the presence of arteriovenous shunting. Our aim was to quantitatively correlate AVM signal intensity on ASL with the degree of arteriovenous shunting estimated on digital subtraction angiography (DSA) in AVMs. MR imaging including pseudo-continuous ASL at 3 T and DSA were obtained on the same day in 40 patients with intracranial AVMs. Two reviewers assessed the nidus and venous signal intensities on ASL images to determine the presence of arteriovenous shunting. Interobserver agreement on ASL between the reviewers was determined. ASL signal intensity of the AVM lesion was correlated with AVM size and the time difference between normal and AVM venous transit times measured from the DSA images. Interobserver agreement between two reviewers for nidus and venous signal intensities was excellent (κ = 0.80 and 1.0, respectively). Interobserver agreement regarding the presence of arteriovenous shunting was perfect (κ = 1.0). AVM signal intensity showed a positive relationship with the time difference between normal and AVM venous transit times (r = 0.638, P < 0.001). AVM signal intensity also demonstrated a positive relationship with AVM size (r = 0.561, P < 0.001). AVM signal intensity on ASL in patients with AVM correlates well with the degree of early vein opacification on DSA, which corresponds to the degree of arteriovenous shunting. (orig.)

  17. Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition.

    Science.gov (United States)

    Wu, Huimin; Block, Walter F; Turski, Patrick A; Mistretta, Charles A; Johnson, Kevin M

    2013-03-01

    Pseudocontinuous arterial spin labeling (PCASL) can be used to generate noncontrast magnetic resonance angiograms of the cerebrovascular structures. Previously described PCASL-based angiography techniques were limited to two-dimensional projection images or relatively low-resolution three-dimensional (3D) imaging due to long acquisition time. This work proposes a new PCASL-based 3D magnetic resonance angiography method that uses an accelerated 3D radial acquisition technique (VIPR, spoiled gradient echo) as the readout. Benefiting from the sparsity provided by PCASL and noise-like artifacts of VIPR, this new method is able to obtain submillimeter 3D isotropic resolution and whole head coverage with a 8-min scan. Intracranial angiography feasibility studies in healthy (N = 5) and diseased (N = 5) subjects show reduced saturation artifacts in PCASL-VIPR compared with a standard time-of-flight protocol. These initial results show great promise for PCASL-VIPR for static, dynamic, and vessel selective 3D intracranial angiography. PMID:22532423

  18. Dopaminergic Therapy Modulates Cortical Perfusion in Parkinson Disease With and Without Dementia According to Arterial Spin Labeled Perfusion Magnetic Resonance Imaging.

    Science.gov (United States)

    Lin, Wei-Che; Chen, Pei-Chin; Huang, Yung-Cheng; Tsai, Nai-Wen; Chen, Hsiu-Ling; Wang, Hung-Chen; Lin, Tsu-Kung; Chou, Kun-Hsien; Chen, Meng-Hsiang; Chen, Yi-Wen; Lu, Cheng-Hsien

    2016-02-01

    Arterial spin labeling (ASL) magnetic resonance imaging analyses allow for the quantification of altered cerebral blood flow, and provide a novel means of examining the impact of dopaminergic treatments. The authors examined the cerebral perfusion differences among 17 Parkinson disease (PD) patients, 17 PD with dementia (PDD) patients, and 17 healthy controls and used ASL-MRI to assess the effects of dopaminergic therapies on perfusion in the patients. The authors demonstrated progressive widespread cortical hypoperfusion in PD and PDD and robust effects for the dopaminergic therapies. Specifically, dopaminergic medications further decreased frontal lobe and cerebellum perfusion in the PD and PDD groups, respectively. These patterns of hypoperfusion could be related to cognitive dysfunctions and disease severity. Furthermore, desensitization to dopaminergic therapies in terms of cortical perfusion was found as the disease progressed, supporting the concept that long-term therapies are associated with the therapeutic window narrowing. The highly sensitive pharmaceutical response of ASL allows clinicians and researchers to easily and effectively quantify the absolute perfusion status, which might prove helpful for therapeutic planning.

  19. Simultaneous multi-slice Turbo-FLASH imaging with CAIPIRINHA for whole brain distortion-free pseudo-continuous arterial spin labeling at 3 and 7 T.

    Science.gov (United States)

    Wang, Yi; Moeller, Steen; Li, Xiufeng; Vu, An T; Krasileva, Kate; Ugurbil, Kamil; Yacoub, Essa; Wang, Danny J J

    2015-06-01

    Simultaneous multi-slice (SMS) or multiband (MB) imaging has recently been attempted for arterial spin labeled (ASL) perfusion MRI in conjunction with echo-planar imaging (EPI) readout. It was found that SMS-EPI can reduce the T1 relaxation effect of the label and improve image coverage and resolution with little penalty in signal-to-noise ratio (SNR). However, EPI still suffers from geometric distortion and signal dropout from field inhomogeneity effects especially at high and ultrahigh magnetic fields. Here we present a novel scheme for achieving high fidelity distortion-free quantitative perfusion imaging by combining pseudo-continuous ASL (pCASL) with SMS Turbo-FLASH (TFL) readout at both 3 and 7 T. Bloch equation simulation was performed to characterize and optimize the TFL-based pCASL perfusion signal. Two MB factors (3 and 5) were implemented in SMS-TFL pCASL and compared with standard 2D TFL and EPI pCASL sequences. The temporal SNR of SMS-TFL pCASL relative to that of standard TFL pCASL was 0.76 ± 0.10 and 0.74 ± 0.11 at 7 T and 0.70 ± 0.05 and 0.65 ± 0.05 at 3T for MB factor of 3 and 5, respectively. By implementing background suppression in conjunction with SMS-TFL at 3T, the relative temporal SNR improved to 0.84 ± 0.09 and 0.79 ± 0.10 for MB factor of 3 and 5, respectively. Compared to EPI pCASL, significantly increased temporal SNR (pbrain distortion-free quantitative mapping of cerebral blood flow at high and ultrahigh magnetic fields.

  20. Impact of neonate haematocrit variability on the longitudinal relaxation time of blood: Implications for arterial spin labelling MRI

    Directory of Open Access Journals (Sweden)

    J.B. De Vis

    2014-01-01

    Conclusion: We demonstrated a wide variability of the T1b in neonates and the implications it could have in methods relying on the actual T1b as for instance ASL. It was concluded that arterial-drawn Hct values obtained from a point-of-care device can be used to infer the T1b whereas our data did not support the use of capillary-drawn Hct for T1b correction.

  1. Arterial spin-labeling MR imaging in moyamoya disease compared with clinical assessments and other MR imaging finings

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Tomoyuki, E-mail: tnogucci@radiol.med.kyushu-u.ac.jp [Department of Radiology, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Kawashima, Masatou [Department of Neurosurgery, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Nishihara, Masashi; Hirai, Tetsuyoshi [Department of Radiology, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Matsushima, Toshio [Department of Neurosurgery, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Irie, Hiroyuki [Department of Radiology, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan)

    2013-12-01

    Purpose: Our purpose was to identify the causal factors for the perfusion distribution obtained with ASL-MRI by comparing ASL-MRI with clinical information and other MRI findings in moyamoya disease. Methods: Seventy-one patients with moyamoya disease underwent ASL-MRI and other MRI, including fluid-attenuated inversion recovery imaging (FLAIR) and three-dimensional time-of-flight magnetic resonance angiography (MRA) on 3.0-Tesla MRI system. Cerebral blood flow (CBF) values (ASL values) for the cerebral hemispheres (142 sides) were measured on CBF maps generated by ASL-MRI. Relationships between the ASL values and the following 9 factors were assessed: sex, family history, revascularization surgery, age at MR exam, age at onset, the steno-occlusive severity on MRA (MRA score), degree of basal collaterals, degree of leptomeningeal high signal intensity seen on FLAIR, and size of ischemic or hemorrhagic cerebrovascular accident lesion (CVA score). Results: Patients with a family history had significantly higher ASL values than those without such a history. There were significant negative correlations between ASL values and age at MR exam, MRA score, and CVA score. Conclusions: ASL-MRI may have cause-and-effect or mutual associations with family history, current patient age, size of CVA lesion, and intracranial arterial steno-occlusive severity in Moyamoya disease.

  2. Changes in cerebral blood flow after transjugular intrahepatic portosystemic shunt can help predict the development of hepatic encephalopathy: An arterial spin labeling MR study

    International Nuclear Information System (INIS)

    Background and purpose: Cerebral blood flow (CBF) changes after transjugular intrahepatic portosystemic shunt (TIPS) are still unclear. Our aim is to assess the TIPS-induced CBF changes and their potential clinical significance using the arterial spin labeling (ASL) perfusion magnetic resonance imaging. Materials and methods: Nine cirrhotic patients underwent ASL 1–8 days before and 4–7 days after TIPS. CBF was calculated at each voxel and mean CBF values were computed in the whole brain, gray matter and white matter. Changes of CBFs before and after TIPS were compared by paired t-test. Results: Voxel-wise results showed CBF diffusely increased in patients after TIPS, but no region with significant decrease in CBF was found, nor was any significant mean CBF difference detected in the whole brain, gray matter and white matter. Six patients out of nine showed a global CBF increase of 9–39%; one patient presented a global CBF decrease of 6%; another two showed a global CBF decrease of 16% and 31% respectively. Follow-up studies showed that the two patients with greatly decreased global CBF suffered from multiple episodes of overt hepatic encephalopathy (OHE) after TIPS and one died of OHE. Conclusions: CBF derived from noninvasive ASL MRI could be used as a useful biomarker to predict the development of OHE through consecutively tracking CBF changes in patients with inserted TIPS. Increased CBFs in many cortical regions could be common effects of the TIPS procedure, while decreased global CBF following TIPS might indicate the development of OHE.

  3. Astrocytic tumour grading: a comparative study of three-dimensional pseudocontinuous arterial spin labelling, dynamic susceptibility contrast-enhanced perfusion-weighted imaging, and diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Hua-Feng [302 Hospital of Chinese People' s Liberation Army, Department of Radiology, Beijing (China); Chen, Zhi-Ye; Wang, Yu-Lin; Wang, Yan; Ma, Lin [People' s Liberation Army General Hospital, Department of Radiology, Beijing (China); Lou, Xin [People' s Liberation Army General Hospital, Department of Radiology, Beijing (China); University of California, Department of Neurology, Los Angeles, CA (United States); Gui, Qiu-Ping [People' s Liberation Army General Hospital, Department of Pathology, Beijing (China); Shi, Kai-Ning; Zhou, Zhen-Yu; Zheng, Dan-Dan [General Electric Healthcare (China) Co., Ltd., Beijing; Wang, Danny J.J. [University of California, Department of Neurology, Los Angeles, CA (United States)

    2015-12-15

    We hypothesized that three-dimensional pseudocontinuous arterial spin labelling (pCASL) may have similar efficacy in astrocytic tumour grading as dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI), and the grading accuracy may be further improved when combined with apparent diffusion coefficient (ADC) values. Forty-three patients with astrocytic tumours were studied using diffusion weighted imaging (DWI), pCASL, and DSC-PWI. Histograms of ADC and normalized tumour cerebral blood flow values (nCBF on pCASL and nrCBF on DSC-PWI) were measured and analyzed. The mean 10 % ADC value was the DWI parameter that provided the best differentiation between low-grade astrocytoma (LGA) and high-grade astrocytoma (HGA). The nCBF and nrCBF (1.810 ± 0.979 and 2.070 ± 1.048) in LGA were significantly lower than those (4.505 ± 2.270 and 5.922 ± 2.630) in HGA. For differentiation between LGA and HGA, the cutoff values of 0.764 x 10{sup -3} mm{sup 2}/s for mean 10 % ADC, 2.374 for nCBF, and 3.464 for nrCBF provided the optimal accuracy (74.4 %, 86.1 %, and 88.6 %, respectively). Combining the ADC values with nCBF or nrCBF could further improve the grading accuracy to 97.7 % or 95.3 %, respectively. pCASL is an alternative to DSC-PWI for astrocytic tumour grading. The combination of DWI and contrast-free pCASL offers a valuable choice in patients with risk factors. (orig.)

  4. Altered cerebral blood flow one month after systemic chemotherapy for breast cancer: a prospective study using pulsed arterial spin labeling MRI perfusion.

    Directory of Open Access Journals (Sweden)

    Kelly N H Nudelman

    Full Text Available Cerebral structural and functional alterations have been reported after chemotherapy for non-CNS cancers, yet the causative mechanism behind these changes remains unclear. This study employed a novel, non-invasive, MRI-based neuroimaging measure to provide the first direct longitudinal measurement of resting cerebral perfusion in breast cancer patients, which was tested for association with changes in cognitive function and gray matter density. Perfusion was measured using pulsed arterial spin labeling MRI in women with breast cancer treated with (N = 27 or without (N = 26 chemotherapy and matched healthy controls (N = 26 after surgery before other treatments (baseline, and one month after chemotherapy completion or yoked intervals. Voxel-based analysis was employed to assess perfusion in gray matter; changes were examined in relation to overall neuropsychological test performance and frontal gray matter density changes measured by structural MRI. Baseline perfusion was not significantly different across groups. Unlike control groups, chemotherapy-treated patients demonstrated significantly increased perfusion post-treatment relative to baseline, which was statistically significant relative to controls in the right precentral gyrus. This perfusion increase was negatively correlated with baseline overall neuropsychological performance, but was not associated with frontal gray matter density reduction. However, decreased frontal gray matter density was associated with decreased perfusion in bilateral frontal and parietal lobes in the chemotherapy-treated group. These findings indicate that chemotherapy is associated with alterations in cerebral perfusion which are both related to and independent of gray matter changes. This pattern of results suggests the involvement of multiple mechanisms of chemotherapy-induced cognitive dysfunction. Additionally, lower baseline cognitive function may be a risk factor for treatment

  5. Astrocytic tumour grading: a comparative study of three-dimensional pseudocontinuous arterial spin labelling, dynamic susceptibility contrast-enhanced perfusion-weighted imaging, and diffusion-weighted imaging

    International Nuclear Information System (INIS)

    We hypothesized that three-dimensional pseudocontinuous arterial spin labelling (pCASL) may have similar efficacy in astrocytic tumour grading as dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI), and the grading accuracy may be further improved when combined with apparent diffusion coefficient (ADC) values. Forty-three patients with astrocytic tumours were studied using diffusion weighted imaging (DWI), pCASL, and DSC-PWI. Histograms of ADC and normalized tumour cerebral blood flow values (nCBF on pCASL and nrCBF on DSC-PWI) were measured and analyzed. The mean 10 % ADC value was the DWI parameter that provided the best differentiation between low-grade astrocytoma (LGA) and high-grade astrocytoma (HGA). The nCBF and nrCBF (1.810 ± 0.979 and 2.070 ± 1.048) in LGA were significantly lower than those (4.505 ± 2.270 and 5.922 ± 2.630) in HGA. For differentiation between LGA and HGA, the cutoff values of 0.764 x 10-3 mm2/s for mean 10 % ADC, 2.374 for nCBF, and 3.464 for nrCBF provided the optimal accuracy (74.4 %, 86.1 %, and 88.6 %, respectively). Combining the ADC values with nCBF or nrCBF could further improve the grading accuracy to 97.7 % or 95.3 %, respectively. pCASL is an alternative to DSC-PWI for astrocytic tumour grading. The combination of DWI and contrast-free pCASL offers a valuable choice in patients with risk factors. (orig.)

  6. Cerebral blood flow measured by arterial-spin labeling MRI: A useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis

    International Nuclear Information System (INIS)

    Purpose: To investigate the role of arterial-spin labeling (ASL) MRI to non-invasively characterize the patterns of cerebral blood flow (CBF) changes in cirrhotic patients and to assess the potential of ASL MRI to characterize minimal hepatic encephalopathy (MHE). Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Thirty six cirrhosis patients without overt hepatic encephalopathy (16 MHE patients and 20 non hepatic encephalopathy (non-HE) patients) and 25 controls underwent ASL MRI, and CBF was measured for each subject. One-way ANOCOVA test with age and gender as covariences was used to compare CBF difference among three groups, and post hoc analysis was performed between each two groups. Region-based correlation analysis was applied between Child–Pugh score, venous blood ammonia level, neuropsychological tests and CBF values in cirrhosis patients. Receiver operator characteristic (ROC) analysis was used for assessing CBF measurements in ASL MRI to differentiate MHE from non-HE patients. Results: The gray matter CBF of MHE patients (71.09 ± 11.88 mL min−1 100 g−1) was significantly higher than that of non-HE patients (55.28 ± 12.30 mL min−1 100 g−1, P < 0.01) and controls (52.09 ± 9.27 mL min−1 100 g−1, P < 0.001). Voxel-wise ANOCOVA results showed that CBFs were significantly different among three groups in multiple gray matter areas (P < 0.05, Bonferroni corrected). Post hoc comparisons showed that CBF of these brain regions was increased in MHE patients compared with controls and non-HE patients (P < 0.05, Bonferroni corrected). CBF of the right putamen was of the highest sensitivity (93.8%) and moderate specificity (75.0%) for characterization of MHE when using the cutoff value of 50.57 mL min−1 100 g−1. CBFs in the bilateral median cingulate gyri, left supramarginal gyrus, right angular gyrus, right heschl gyrus and right superior temporal gyrus

  7. Cerebral blood flow measured by arterial-spin labeling MRI: A useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Gang [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu, 210016 (China); Zhang, Long Jiang, E-mail: kevinzhlj@163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Zhong, Jianhui [Department of Imaging Sciences, University of Rochester School of Medicine and Dentistry, Box648, 601 Elmwood Avenue, Rochester, NY 14642-8648 (United States); Wang, Ze [Department of Psychiatry, Perelman School of Medicine, University of Pennsylvania, 3900 Chestnut St., Philadelphia, PA 19104 (United States); Qi, Rongfeng; Shi, Donghong [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Lu, Guang Ming, E-mail: cjr.luguangming@vip.163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China)

    2013-11-01

    Purpose: To investigate the role of arterial-spin labeling (ASL) MRI to non-invasively characterize the patterns of cerebral blood flow (CBF) changes in cirrhotic patients and to assess the potential of ASL MRI to characterize minimal hepatic encephalopathy (MHE). Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Thirty six cirrhosis patients without overt hepatic encephalopathy (16 MHE patients and 20 non hepatic encephalopathy (non-HE) patients) and 25 controls underwent ASL MRI, and CBF was measured for each subject. One-way ANOCOVA test with age and gender as covariences was used to compare CBF difference among three groups, and post hoc analysis was performed between each two groups. Region-based correlation analysis was applied between Child–Pugh score, venous blood ammonia level, neuropsychological tests and CBF values in cirrhosis patients. Receiver operator characteristic (ROC) analysis was used for assessing CBF measurements in ASL MRI to differentiate MHE from non-HE patients. Results: The gray matter CBF of MHE patients (71.09 ± 11.88 mL min{sup −1} 100 g{sup −1}) was significantly higher than that of non-HE patients (55.28 ± 12.30 mL min{sup −1} 100 g{sup −1}, P < 0.01) and controls (52.09 ± 9.27 mL min{sup −1} 100 g{sup −1}, P < 0.001). Voxel-wise ANOCOVA results showed that CBFs were significantly different among three groups in multiple gray matter areas (P < 0.05, Bonferroni corrected). Post hoc comparisons showed that CBF of these brain regions was increased in MHE patients compared with controls and non-HE patients (P < 0.05, Bonferroni corrected). CBF of the right putamen was of the highest sensitivity (93.8%) and moderate specificity (75.0%) for characterization of MHE when using the cutoff value of 50.57 mL min{sup −1} 100 g{sup −1}. CBFs in the bilateral median cingulate gyri, left supramarginal gyrus, right angular gyrus, right

  8. Vessel encoded arterial spin labeling with cerebral perfusion: preliminary study%血管编码动脉自旋标记MR脑灌注成像初步研究

    Institute of Scientific and Technical Information of China (English)

    吴冰; 蒋学祥; 方竞; 王晶; 郭佳; 章蓓茹; 肖江喜; 谢晟; Eric C.Wong; 张珏; 王霄英

    2008-01-01

    目的 初步应用血管编码动脉自旋标记MR脑灌注成像技术选择件标记双侧颈内动脉及后循环的血流分布区.方法 使用伪连续动脉自旋标记成像方法 对7名健康志愿者和6例脑血管病患者的左、右颈内动脉及椎基底动脉编码进行头部横断而成像和图像后处理,得到来源于上述不同血管的脑血流量(CBF)的灌注分布图,计算7名志愿者的双侧大脑厌、白质及半脑的CBF.比较脑血管病患者的血流分布结果 与DSA图像的一致性及低灌注区域与液体衰减反转恢复(FLAIR)T2WI的高信号区域大小.结果 定量测量正常志愿者的半CBF为(32.6±4.3)ml·min-1·100 g-1,脑白质血流最(10.8±0.9)ml·min-1·100 g-1,脑灰质血流量(55.6±2.9)ml·min-1·100 g-1.脑血管病患者的脑血流分布异常、侧支循环血流分布与DSA对应良好;所有患者低灌注区域比FLAIR T2WI显示的高信号区域范围更大.结论 血管编码动脉自旋标记MR脑灌注成像可以无创地定性并定量不同血管来源的脑血供.%Objective To evaluate a noninvasive vessel encoded imaging for selective mapping of the flow territories of the left and right internal carotid arteries and vertebral-basilar arteries. Methods Seven volunteers [(33.5±4.1) years ; 3 men, 4 women] and 6 patients [(55.2 ± 3.2) years; 2 men,4women] were given written informed consent approved by the institutional review board before participating in the study. A pseudo-continuous tagging pulse train is modified to encode all vessels of interest. The selectivity of this method was demonstrated. Regional perfusion imaging was developed on the same arterial spin labeling sequence. Perfusion-weighted images of the selectively labeled cerebral arteries were obtained by subtraction of the labeled from control images. The CBF values of hemisphere, white matter, and gray matter of volunteers were calculated. The vessel territories on patients were compared with DSA. The low

  9. Using intravoxel incoherent motion MR imaging to study the renal pathophysiological process of contrast-induced acute kidney injury in rats: Comparison with conventional DWI and arterial spin labelling

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Long; Zhang, Bin [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Southern Medical University, Graduate College, Guangzhou (China); Chen, Wen-bo; Liang, Chang-hong; Zhang, Shui-xing [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Chan, Kannie W.Y.; Li, Yu-guo; Liu, Guan-shu [The Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of MR Research, Baltimore, MD (United States)

    2016-06-15

    To investigate the potential of intravoxel incoherent motion (IVIM) to assess the renal pathophysiological process in contrast-induced acute kidney injury (CIAKI). Twenty-seven rats were induced with CIAKI model, six rats were imaged longitudinally at 24 h prior to and 30 min, 12, 24, 48, 72 and 96 h after administration; three rats were randomly chosen from the rest for serum creatinine and histological studies. D, f, D* and ADC were calculated from IVIM, and renal blood flow (RBF) was obtained from arterial spin labelling (ASL). A progressive reduction in D and ADC was observed in cortex (CO) by 3.07 and 8.62 % at 30 min, and by 25.77 and 28.16 % at 48 h, respectively. A similar change in outer medulla (OM) and inner medulla (IM) was observed at a later time point (12-72 h). D values were strongly correlated with ADC (r = 0.885). As perfusion measurement, a significant decrease was shown for f in 12-48 h and an increase in 72-96 h. A slightly different trend was found for D*, which was decreased by 26.02, 21.78 and 10.19 % in CO, OM and IM, respectively, at 30 min. f and D* were strongly correlated with RBF in the cortex (r = 0.768, r = 0.67), but not in the medulla. IVIM is an effective imaging tool for monitoring progress in renal pathophysiology undergoing CIAKI. (orig.)

  10. Using intravoxel incoherent motion MR imaging to study the renal pathophysiological process of contrast-induced acute kidney injury in rats: Comparison with conventional DWI and arterial spin labelling

    International Nuclear Information System (INIS)

    To investigate the potential of intravoxel incoherent motion (IVIM) to assess the renal pathophysiological process in contrast-induced acute kidney injury (CIAKI). Twenty-seven rats were induced with CIAKI model, six rats were imaged longitudinally at 24 h prior to and 30 min, 12, 24, 48, 72 and 96 h after administration; three rats were randomly chosen from the rest for serum creatinine and histological studies. D, f, D* and ADC were calculated from IVIM, and renal blood flow (RBF) was obtained from arterial spin labelling (ASL). A progressive reduction in D and ADC was observed in cortex (CO) by 3.07 and 8.62 % at 30 min, and by 25.77 and 28.16 % at 48 h, respectively. A similar change in outer medulla (OM) and inner medulla (IM) was observed at a later time point (12-72 h). D values were strongly correlated with ADC (r = 0.885). As perfusion measurement, a significant decrease was shown for f in 12-48 h and an increase in 72-96 h. A slightly different trend was found for D*, which was decreased by 26.02, 21.78 and 10.19 % in CO, OM and IM, respectively, at 30 min. f and D* were strongly correlated with RBF in the cortex (r = 0.768, r = 0.67), but not in the medulla. IVIM is an effective imaging tool for monitoring progress in renal pathophysiology undergoing CIAKI. (orig.)

  11. Glial fibrillary acidic protein (GFAP) immunoreactivity correlates with cortical perfusion parameters determined by bolus tracking arterial spin labelling (bt-ASL) magnetic resonance (MR) imaging in the Wistar Kyoto rat.

    Science.gov (United States)

    Gormley, Shane; Rouine, Jennifer; McIntosh, Allison; Kerskens, Christian; Harkin, Andrew

    2016-06-01

    Alterations in astrocyte number and function have been implicated in the pathophysiology of a number of psychiatric disorders. The development of magnetic resonance imaging (MRI) as a tool in the animal laboratory has enabled an investigation of the relationship between pathological and neuroimaging markers in animal models. However the physiological processes which underlie these markers and their role in mediating behavioural deficits is still poorly understood. Rodent models have provided us with important insights into physiological and cellular mechanisms which may mediate anxiety and depression-related behaviours. The Wistar-Kyoto (WKY) rat is a strain which endogenously expresses highly anxious and depressive-like behaviours and has previously been reported to exhibit alterations in immunoreactivity for the astrocytic marker glial fibrillary acidic protein (GFAP) in brain sub-regions relative to more stress resilient out-bred strains. Here we report that the depressive and anxiety-like behaviours exhibited by the WKY rat strain are associated with alterations in brain morphology including a decrease in hippocampal volume, coupled with reduced resting state frontal cortical perfusion as assessed by MR bolus tracking arterial spin labelling (bt-ASL) relative to the out-bred Wistar strain. Pre-limbic cortical GFAP immunoreactivity and astrocyte cell number were positively correlated with cortical blood perfusion in the WKY strain. These experiments provide a link between pathological and neuroimaging markers of aberrant astrocytic function and add validity to the WKY rat as a model for co-morbid anxiety and depression. PMID:27068181

  12. Pseudocontact shifts from mobile spin labels

    CERN Document Server

    Suturina, E

    2016-01-01

    This paper presents a detailed analysis of the pseudocontact shift (PCS) field induced by a mobile spin label that is viewed as a probability density distribution with an associated magnetic susceptibility. It is demonstrated that anisotropy in this density can lead to significant deviations from the commonly used point dipole approximation for PCS. Analytical and numerical solutions are presented for the general partial differential equation that describes the non-point case. It is also demonstrated that it is possible to reconstruct paramagnetic centre probability distributions from experimental PCS data.

  13. 脉冲式及伪连续式动脉自旋标记技术静息态脑灌注对比研究%Comparative Study of Cerebral Perfusion by Using Pulsed and Pseudo Continuous Arterial Spin Labeling Techniques in Resting State

    Institute of Scientific and Technical Information of China (English)

    陈春晓; 郭超; 郑罡; 王利; 赵铁柱; 卢光明

    2013-01-01

    比较研究了脉冲式动脉自旋标记(pulsed arterial spin labeling,PASL)和伪连续式动脉自旋标记(pseudo continuous arterial spin labeling,pCASL)两种磁共振成像技术在静息态脑灌注中的应用.在静息态下,采用两种动脉自旋标记技术采集了10例健康志愿者的脑灌注数据,并计算脑血流量.两种技术的测量结果均显示,人脑默认网络中的楔前叶、角回、岛叶和后扣带回的相对脑血流量高于全脑平均灌注,而pCASL更敏感.在白质、额叶、顶叶、小脑和小脑蚓区域,pCASL和PASL测量得到的灌注值有显著性差异,除枕叶、小脑和小脑蚓外,PASL测量得到的灌注量小于pCASL.在全脑范围内,pCASL的信噪比明显高于PASL,且负灌注量很少.实验表明,pCASL可以提供比PASL更准确的测量结果.%The comparative study between pulsed arterial spin labeling (PASL) and pseudo continuous arterial spin labeling (pCASL) in resting cerebral perfusion were investigated. The PASL and pCASL data of 10 healthy subjects were acquired by a 3.0 T MR scanner during resting state, and the relative cerebral blood flows (rCBF) were then respectively quantified and analyzed. The results revealed that both techniques were able to detect the rCBF. CBFs in the precuneus, angular gyrus, insula, posterior cingulate cortex in default network were higher than the mean CBF in the whole brain, and pCASL was much more sensitive. Comparison with PASL sequence, CBFs obtained by the pCASL were significantly higher in white matter, frontal and parietal lobe, cerebellum and cerebellar vermis than that of PASL. Moreover, in the whole brain, higher SNR and less negative perfusion voxels were found in pCASL. The experimental results show that pCASL provides more accurate measurements than PASL in cerebral blood flow perfusion.

  14. Application of ESR spin label oximetry in food science.

    Science.gov (United States)

    Zhou, Yu-Ting; Yin, Jun-Jie; Lo, Y Martin

    2011-12-01

    Lipid oxidation attributed to the presence of oxygen has long been a focal area for food science research due in early years mainly to its broad impact on the quality and shelf stability. The need to effectively strategize interventions to detect and eventually eliminate lipid oxidation in food remains as evidence on nutritional and health implications continue to accumulate. Electron spin resonance (ESR) spin label oximetry has been shown capable of detecting dissolved oxygen concentration in both liquid and gaseous phases based on the collision between oxygen and stable free radicals. This review aimed to summarize not just the principles and rationale of ESR spin label oximetry but also the wide spectrum of ESR spin label oximetry applications to date. The feasibility to identify in very early stage oxygen generation and consumption offers a promising tool for controlling lipid oxidation in food and biological systems.

  15. New Developments in Spin Labels for Pulsed Dipolar EPR

    Directory of Open Access Journals (Sweden)

    Alistair J. Fielding

    2014-10-01

    Full Text Available Spin labelling is a chemical technique that enables the integration of a molecule containing an unpaired electron into another framework for study. Given the need to understand the structure, dynamics, and conformational changes of biomacromolecules, spin labelling provides a relatively non-intrusive technique and has certain advantages over X-ray crystallography; which requires high quality crystals. The technique relies on the design of binding probes that target a functional group, for example, the thiol group of a cysteine residue within a protein. The unpaired electron is typically supplied through a nitroxide radical and sterically shielded to preserve stability. Pulsed electron paramagnetic resonance (EPR techniques allow small magnetic couplings to be measured (e.g., <50 MHz providing information on single label probes or the dipolar coupling between multiple labels. In particular, distances between spin labels pairs can be derived which has led to many protein/enzymes and nucleotides being studied. Here, we summarise recent examples of spin labels used for pulse EPR that serve to illustrate the contribution of chemistry to advancing discoveries in this field.

  16. Technological advances in site-directed spin labeling of proteins.

    Science.gov (United States)

    Hubbell, Wayne L; López, Carlos J; Altenbach, Christian; Yang, Zhongyu

    2013-10-01

    Molecular flexibility over a wide time range is of central importance to the function of many proteins, both soluble and membrane. Revealing the modes of flexibility, their amplitudes, and time scales under physiological conditions is the challenge for spectroscopic methods, one of which is site-directed spin labeling EPR (SDSL-EPR). Here we provide an overview of some recent technological advances in SDSL-EPR related to investigation of structure, structural heterogeneity, and dynamics of proteins. These include new classes of spin labels, advances in measurement of long range distances and distance distributions, methods for identifying backbone and conformational fluctuations, and new strategies for determining the kinetics of protein motion.

  17. Technological advances in site-directed spin labeling of proteins

    OpenAIRE

    Hubbell, Wayne L.; López, Carlos J.; Altenbach, Christian; Yang, Zhongyu

    2013-01-01

    Molecular flexibility over a wide time range is of central importance to the function of many proteins, both soluble and membrane. Revealing the modes of flexibility, their amplitudes, and time scales under physiological conditions is the challenge for spectroscopic methods, one of which is site-directed spin labeling EPR (SDSL-EPR). Here we provide an overview of some recent technological advances in SDSL-EPR related to investigation of structure, structural heterogeneity, and dynamics of pr...

  18. 基于动脉自旋标记技术的内侧颞叶癫痫病人脑血流灌注成像研究%A Cerebral Blood Flow Perfusion Analysis in Patients with Temporal Lobe Epilepsy by Use of Arterial Spin Labeled Perfusion MR Imaging

    Institute of Scientific and Technical Information of China (English)

    郭超; 郑罡; 陈春晓; 沈连芳; 张志强; 王利; 卢光明

    2011-01-01

    Using arterial spin labeling (ASL), the authors have studied and analyzed the present of perfusion abnormalities in patients with mesial temporal lobe epilepsy (mTLE). 30 interictal patients with mTLE and hippocampal sclerosis (HS) including 16 patients with left mTLE (LTLE) and 14 patients with right mTLE (RTLE), and 22 healthy volunteers underwent pulsed ASL (PASL) in resting state. Relative cerebral blood flow (rCBF) was calculated and compared using group analysis of statistic parameters mapping and perfusion asymmetric index of region of interest. The results demonstrated that compared to controls, the rCBF of epileptics decreased in bilateral parahippocampal, fusiform, frontal lobe, temporal lobe and ipsilateral insula, and hippocampus in patients with LTLE, bilateral hippocampus, parahippocampal, fusiform, frontal lobe and temporal lobe, and ipsilateral amygdale and insula in patients with RTLE, but decreasing degree and area in ipsilateral side was much more than contralateral side. This study provided evidences that the HS may cause functional abnormalities in seizure zones and influence the whole brain through seizures in patients with mTLE.%基于动脉自旋标记(arterial spin labeling,ASL)技术,分析内侧颞叶癫痫(mesialtemporal lobe epilepsy,mTLE)患者大脑血流灌注(perfusion)的改变情况.在静息态下,采集了30例内侧颞叶癫痫伴单侧海马硬化发作间期患者(其中左侧16例,右侧14例)及22例健康志愿者的ASL数据,并通过计算获取其相对脑血流量(relative CBF,rCBF)及灌注不对称率(asymmetric index,AI).癫痫病人与正常人的比较结果表明:左侧mTLE患者在两侧海马旁回、梭状回、额叶、颞叶和患侧海马回及岛叶,右侧mTLE患者在两侧海马回、海马旁回、额叶、颞叶和患侧杏仁核及岛叶,rCBF均有所下降,且患侧的下降程度和范围均大于对侧.说明mTLE患者的海马硬化可能导致了痫灶区功能异常,并通过癫痫的发作影响到全脑.

  19. Nanoscale imaging of paramagnetic spin labels using a single spin in diamond

    Science.gov (United States)

    Ariyaratne, Amila; Myers, Bryan; Pelliccione, Matthew; Jayich, Ania

    Spin-labeling molecules with paramagnetic species is a powerful technique for probing molecular structure. However, current techniques are ensemble measurements, inherently lacking the sensitivity to detect a single spin or the conformational properties of a single biomolecule. In this talk, we demonstrate an imaging technique that has the promise of single-spin imaging and ultimately molecular structure imaging. We present two-dimensional nanoscale imaging of a monolayer of gadolinium (Gd) atomic spin labels at ambient conditions. The sensing element is a single nitrogen-vacancy (NV) center in diamond. A patterned monolayer of Gd atoms self-assembled on a Si atomic force microscopy tip is controllably interacted with and detected by the NV center. The fluctuating magnetic field generated by GHz-scale Gd spin flips relaxes the NV center in a manner that depends strongly on the Gd-NV separation. Using this technique, we demonstrate a Gd-induced reduction of the T1 relaxation time of the NV center with nm spatial resolution. Our results indicate that nanometer-scale imaging of individual electronic spins at ambient conditions is within reach. This will ultimately enable the study of structural and functional studies of single biomolecules in their native, folded state.

  20. Peptide-membrane Interactions by Spin-labeling EPR

    Science.gov (United States)

    Smirnova, Tatyana I.; Smirnov, Alex I.

    2016-01-01

    Site-directed spin labeling (SDSL) in combination with Electron Paramagnetic Resonance (EPR) spectroscopy is a well-established method that has recently grown in popularity as an experimental technique, with multiple applications in protein and peptide science. The growth is driven by development of labeling strategies, as well as by considerable technical advances in the field, that are paralleled by an increased availability of EPR instrumentation. While the method requires an introduction of a paramagnetic probe at a well-defined position in a peptide sequence, it has been shown to be minimally destructive to the peptide structure and energetics of the peptide-membrane interactions. In this chapter, we describe basic approaches for using SDSL EPR spectroscopy to study interactions between small peptides and biological membranes or membrane mimetic systems. We focus on experimental approaches to quantify peptide-membrane binding, topology of bound peptides, and characterize peptide aggregation. Sample preparation protocols including spin-labeling methods and preparation of membrane mimetic systems are also described. PMID:26477253

  1. Larmor labeling of neutron spin using superconducting Wollaston prisms

    Science.gov (United States)

    Li, Fankang

    Neutron spin Larmor labeling using magnetic Wollaston prisms (WP) provides a way to overcome some of the limitations arising from the nature of neutron beams: low flux and divergence. Using superconducting films and tapes, a series of strong, well-defined shaped magnetic fields can be produced due to both the zero-resistance and Meissner effect in superconductors. Using finite element simulations, the criterion to build a superconducting magnetic Wollaston prism with high encoding efficiency and low Larmor phase aberrations are presented. To achieve a high magnetic field and simplify the maintenance, we optimize the design using careful thermal analysis. The measured neutron spin flipping efficiency is measured to be independent of both the neutron wavelength and energizing current, which is a significant improvement over other devices with similar functions. A highly linear variation of the Larmor phase is measured across the device, which ensures a highly uniform encoding of scattering angles into the neutron spin Larmor phase. Using two WPs, the correlation function for a colloidal silica sample was measured by spin echo modulated small angle neutron scattering (SEMSANS) and agrees well with other techniques. Using Monte Carlo code (McStas), we further investigated the SEMSANS setup and showed the requirements to improve its performance. We have proposed a new technique to implement neutron spin echo on a triple axis neutron spectrometer to achieve high resolution measurements of the lifetime of dispersive phonon excitations. The spin echo is tuned by appropriate choice of magnetic fields instead of physically tilting the coils used in traditional methods. This new approach allows a higher energy resolution and a larger effective tilting angle and hence larger group velocity to be measured.

  2. RosettaEPR: rotamer library for spin label structure and dynamics.

    Directory of Open Access Journals (Sweden)

    Nathan S Alexander

    Full Text Available An increasingly used parameter in structural biology is the measurement of distances between spin labels bound to a protein. One limitation to these measurements is the unknown position of the spin label relative to the protein backbone. To overcome this drawback, we introduce a rotamer library of the methanethiosulfonate spin label (MTSSL into the protein modeling program Rosetta. Spin label rotamers were derived from conformations observed in crystal structures of spin labeled T4 lysozyme and previously published molecular dynamics simulations. Rosetta's ability to accurately recover spin label conformations and EPR measured distance distributions was evaluated against 19 experimentally determined MTSSL labeled structures of T4 lysozyme and the membrane protein LeuT and 73 distance distributions from T4 lysozyme and the membrane protein MsbA. For a site in the core of T4 lysozyme, the correct spin label conformation (Χ1 and Χ2 is recovered in 99.8% of trials. In surface positions 53% of the trajectories agree with crystallized conformations in Χ1 and Χ2. This level of recovery is on par with Rosetta performance for the 20 natural amino acids. In addition, Rosetta predicts the distance between two spin labels with a mean error of 4.4 Å. The width of the experimental distance distribution, which reflects the flexibility of the two spin labels, is predicted with a mean error of 1.3 Å. RosettaEPR makes full-atom spin label modeling available to a wide scientific community in conjunction with the powerful suite of modeling methods within Rosetta.

  3. Voxel-based analysis of cerebral perfusion changes in Alzheimer's disease using a novel 3D arterial spin-labeling technique%基于体素分析的三维动脉自旋标记成像在阿尔茨海默病脑血流灌注中的应用研究

    Institute of Scientific and Technical Information of China (English)

    凌华威; 张泳; 丁蓓; 黄娟; 张欢; 王涛; 柴维敏; 陈克敏

    2012-01-01

    Objective 3D pulsed continuous arterial spin labeling (ASL) technique was used to study cerebral blood flow (CBF) changes in patients with Alzheimer's disease (AD) in comparison with age- and gender-matched healthy controls. Methods 3D ASL scans was performed in 45 participants (24 AD patients and 21 age- and gender-matched control subjects) covering the entire brain with a 3.0-T MR system. Voxel based analysis was performed using SPM8. Two sample t test (threshold at P<0.05 ) was performed. Results Significant decrease of CBF was observed in bilateral temporal-parietal-occipital cortex and left limbic lobe in AD patients when compared with control group. Interestingly, increased CBF was observed in bilateral thalamus, right caudate nucleus and putamen, paracentral lobule as well as white matter of right temporal lobe. Conclusions Our voxel-based results indicates that ASL-MRI could provide useful perfusion information in AD patients. Because of its easy acquisition and noninvasiveness, ASL-MRI may be an appealing alternative approach for further pathologic and neuropsychological studies of AD.%目的:利用三维(3D)动脉自旋标记(arterial spin labeling,ASL)成像技术探讨阿尔茨海默病(Alzheimer's disease,AD)患者的脑血流灌注特征.方法:选择24例AD患者和21名年龄、性别匹配的健康老年人,采用ASL序列进行灌注成像.将获取的脑血流图像(cerebral blood flow,CBF)采用基于体素分析方法经后处理配准进行全脑分析,比较2组的脑血流灌注情况,并探讨AD患者的脑血流灌注特征.结果:与正常老年人相比,AD患者的双侧颞枕顶叶皮层、左侧边缘叶及左侧胼胝体压部的脑血流量CBF明显降低,同时双侧丘脑、右侧壳核、右尾状核头部及右侧颞叶白质区的CBF明显增高.结论:基于体素的ASL全脑分析揭示了AD认知损害过程中相关脑区的血流灌注异常,作为一种无创的血流动力学检查新技术,ASL可能对进一步研究AD

  4. Detection of atomic spin labels in a lipid bi-layer using a single-spin nanodiamond probe

    CERN Document Server

    Kaufmann, Stefan; Hall, Liam T; Perunicic, Viktor; Senn, Philipp; Steinert, Steffen; McGuinness, Liam P; Johnson, Brett C; Ohshima, Takeshi; Caruso, Frank; Wrachtrup, Joerg; Scholten, Robert E; Mulvaney, Paul; Hollenberg, Lloyd C L

    2013-01-01

    Magnetic field fluctuations arising from fundamental spins are ubiquitous in nanoscale biology, and are a rich source of information about the processes that generate them. However, the ability to detect the few spins involved without averaging over large ensembles has remained elusive. Here we demonstrate the detection of gadolinium spin labels in an artificial cell membrane under ambient conditions using a single-spin nanodiamond sensor. Changes in the spin relaxation time of the sensor located in the lipid bilayer were optically detected and found to be sensitive to near-individual proximal gadolinium atomic labels. The detection of such small numbers of spins in a model biological setting, with projected detection times of one second, opens a new pathway for in-situ nanoscale detection of dynamical processes in biology.

  5. Spin Labeling ESR Investigation of Covalently Bound Residues in Soil

    Science.gov (United States)

    Aleksandrova, Olga; Steinhoff, Heinz-Juergen; Klasmeier, Joerg; Schulz, Marcus; Matthies, Michael

    2013-04-01

    Organic xenobiotic chemicals, such as pesticides, biocides and veterinary pharmaceuticals, interact with soil, which results in the simultaneous formations of metabolites, mineralization products, and bound or non-extractable residues (NER). Substances or metabolites with reactive functional groups, such as aniline or phenol, have a tendency to give a larger proportion of NER. Despite numerous studies on NER, the majority of their chemical structures is still unknown. Reversible sequestration and irreversible formation of NER were also observed for veterinary antibiotic pharmaceuticals, after their application to soil with and without manure. For this purpose, we hypothesized a key role of specific functional groups of soil contaminants, via which contaminants are covalently bound to soil constituents, and advance a method of spin labeling ESR investigation of reaction products using a membrane method. Spin labels (SL) represent chemically stable paramagnetic molecules used as molecular labels and molecular probes for testing the covalent binding, structural properties, and molecular mobility of different physical, chemical, and biological systems. In the case of covalent binding of SL, their ESR spectra become broadened. We used stable nitroxide radicals (NR) as SL. These radicals modeled organic chemical contaminants and differed only in one functional group. The paramagnetic SL 4-Amino Tempo (4-amino-2,2,6,6-tetramethyl-1-piperidinylox) differed from Tempo (2,2,6,6-Tetramethylpiperidinooxy) in a substituent at the para-position of the piperidine ring, whereas Aniline Tempo (1-Piperidinyloxy, 2,2,6,-tetramethyl, 6-Aniline) differed from Tempo in an Aniline substituting one CH3 functional group. Before experimental analysis, we tested temporal changes in the concentration of both NR incubated with soil and found that the life-times of them in soil exceeded 3 days. We contaminated and labeled soil samples with NR, adding to soil the aqueous solution, which already

  6. Distance determination between low-spin ferric haem and nitroxide spin label using DEER: the neuroglobin case

    Science.gov (United States)

    Ezhevskaya, M.; Bordignon, E.; Polyhach, Y.; Moens, L.; Dewilde, S.; Jeschke, G.; Van Doorslaer, S.

    2013-10-01

    This work demonstrates for the first time the feasibility of using double electron-electron resonance (DEER) to determine the inter-spin distance between nitroxide spin labels and low-spin (S = 1/2) ferric haem centres. For these means, two human neuroglobin variants were spin labelled leading to singly labelled haem proteins with the nitroxide label on one of the natural Cys residues (Cys55 or Cys120). Room-temperature electron paramagnetic resonance was used to characterise the mobility of the nitroxide labels and X- and Q-band DEER experiments were performed to detect nitroxide-haem distances. Effects of residual nuclear modulations in the DEER traces were carefully evaluated. The DEER-derived distances were compared with theoretical predictions from an X-ray diffraction structure of human neuroglobin using a rotamer library approach as well as with distance information obtained from electron relaxation measurements. The structural biological implications of the spin-labelled side chains' dynamics and of the obtained distances are also discussed.

  7. Intra-and Inter-Scanner Test-Retest Reliability in Pseudo-continuous Arterial Spin-labeling MR Imaging of Auditory Cortex Perfusion in Healthy Adults%正常成人听皮层磁共振动脉自旋标记灌注成像的可重复性研究

    Institute of Scientific and Technical Information of China (English)

    娄昕; 吴冰; 吴新淮; 纵亮; 黄点点; 王秋菊; 马林

    2013-01-01

    Objective To assess intra-and inter-scanner test-retest reliability in 3D whole-brain pseudo-continu⁃ous arterial spin labeling (pCASL) of the auditory cortex in healthy adults. Methods Eight healthy subjects were scanned three times on two 3.0T MR scanners with 3D whole-brain pCASL technique. The 1st and 3rd tests were done on Scanner 1 and the 2nd test on Scanner 2. Intervals between tests were 10~15 days. Two sets of ASL data with post labeling delay time (PLD) at 1.5 or 2.5 seconds were acquired during each test. Volumetric T1-weighted images of the whole brain were also ac⁃quired for image registration. Cerebral blood flow (CBF) values of the auditory cortex were extracted for comparison. The in⁃tra-and inter-scanner test-retest reliability was evaluated with the intraclass correlation coefficient (ICC) and Bland-Alt⁃man plots. Results Overall, the auditory cortex CBF value was 51~61 ml/min/100g for PLD=1.5s and 43~54 ml/min/100g for PLD=2.5s. For PLD=1.5s, the ICC was 0.50 for comparison between the 1st and 2nd tests, 0.83 for comparison between the 2nd and 3rd tests, and 0.85 for comparison between the 1st and 3rd tests. For PLD=2.5s, the ICC was 0.76 for comparison be⁃tween the 1st and 2nd tests, 0.89 for comparison between the 2nd and 3rd tests and 0.88 for comparison between the 1st and 3rd tests. Bland-Altman plots indicated better reproducibility for PLD=2.5s than for PLD=1.5s. Conclusions The 3D whole-brain pCASL technique can be used for measuring CBF in the auditory cortex with high test-retest reliability, which indicates its value in MR research on blood flow of the auditory cortex across multiple centers.%  目的研究正常成人听皮层磁共振三维动脉自旋标记灌注成像(three dimensional arterial spin labeling,3D ASL)技术的可重复性.方法8例健康成年人在2台同一机型的3.0T磁共振扫描仪上进行了3次全脑3D ASL序列扫描,在1号扫描仪上进行第1次和第3次扫描,在2

  8. Parametrization, molecular dynamics simulation and calculation of electron spin resonance spectra of a nitroxide spin label on a poly-alanine alpha helix

    OpenAIRE

    Sezer, Deniz; Freed, Jack H.; Roux, Benoît

    2008-01-01

    The nitroxide spin label 1-oxyl-2,2,5,5-tetramethylpyrroline-3-methyl-methanethiosulfonate (MTSSL), commonly used in site-directed spin labeling of proteins, is studied with molecular dynamics (MD) simulations. After developing force field parameters for the nitroxide moiety and the spin label linker, we simulate MTSSL attached to a poly-alanine alpha helix in explicit solvent to elucidate the factors affecting its conformational dynamics. Electron spin resonance spectra at 9 and 250 GHz are ...

  9. Arterial spin labeling perfusion MRI in cerebral ischaemia

    NARCIS (Netherlands)

    Bokkers, R.P.H.

    2011-01-01

    Cerebral perfusion is the basis for the delivery of oxygen and nutrients to the brain. Brain tissue can become damaged when there is a shortage in the blood supply. Basic physiological functions such as synaptic transmission, the membrane ion pump and energy metabolism are disrupted and within minut

  10. Imaging of cerebral hemodynamics with arterial spin labeling

    NARCIS (Netherlands)

    Hartkamp, N.S.

    2014-01-01

    A knowledge of the cerebral circulation is of great importance in the understanding cerebrovascular disease. The ability to visualize the brain vasculature has become key in the diagnosis and treatment of cerebrovascular disease. Modern imaging modalities, such as digital subtraction angiography, co

  11. Detection of renal arteries with fast spin-echo magnetic resonance imaging

    International Nuclear Information System (INIS)

    With the increasing use of non-invasive imaging with MR and volumetric CT to evaluate renal arteries, the ability to accurately detect the number and state of native renal arteries becomes critical if conventional angiography is to be supplanted in these settings. The present study evaluated the utility of a fast spin-echo (FSE) T2-weighted sequence to detect the number and course of renal arteries and their ostia compared to conventional angiography. Ten patients underwent conventional catheter angiography either for renal artery stenosis evaluation or as potential renal donors. Each patient then had an MR study of the renal arteries and kidneys with FSE MR (TR = 4000 ms, TE = 102 ms, eight- echo train length, 5-mm-thick interleaved 128 phase encodes, superior and inferior saturation pulses, number of excitations (NEX) = 4, on a 1.5-T superconducting magnet. Images were reviewed by two 'blinded' radiologists and renal arteries were counted and their ostia were evaluated. Results were compared with angiography and inter- and intra-observer statistics were calculated. All 10 patients underwent MR successfully, nine for renal artery stenosis (RAS) evaluation and one was a renal donor. A total of 24 renal arteries were imaged in 19 kidneys. Fast spin-echo MR is 95% accurate (95%CI: 88-100%) in detection of renal arteries, with no statistical difference between FSE MR and catheter angiography (McNemar P = 0.0). Inter- and intra-observer statistics demonstrate good-to-excellent agreement in renal artery detection (kappa: 0.63-0.90). In one case of RAS evaluation an incidental adrenal mass was detected as the aetiology of the patient's hypertension. Fast spin-echo MR can be a useful adjunct as part of the imaging for renal arteries with MRI. Copyright (1998) Blackwell Science Pty Ltd

  12. Self-aggregation properties of spin-labeled zervamicin IIA as studied by PELDOR spectroscopy.

    Science.gov (United States)

    Milov, A D; Tsvetkov, Yu D; Gorbunova, E Yu; Mustaeva, L G; Ovchinnikova, T V; Raap, J

    2002-09-01

    In this article, the pulsed double electron-electron resonance in electron spin-echo (PELDOR) technique is applied to study the self-aggregation of spin-labeled zervamicin IIA, a hexadecapeptide antibiotic of fungal origin, which is known to form ion channels in a phospholipid double layer. Measurements of the ion channel forming properties and the antibiotic activity of the analog indicate that replacement of the C-terminal phenylalaninol by the amino-2,2,6,6-tetramethylpiperidinyloxy (TEMPO) residue does not influence the biophysical and biological properties. The dipole-dipole interaction between the spin labels of the fully biologically active peptide analog was studied in frozen (77 K) glassy solutions in different ratios of toluene-methanol. The spin-labeled zervamicin IIA molecules were shown to form aggregates. An average distance between the spin labels in the aggregates was estimated to be in the range of 25-35 A (depending on the solvent composition), indicating that the amphiphilic helical peptide molecules are oriented in an antiparallel fashion. Increasing of methanol content in the solution results in a loosening of the aggregate structure. It was shown that the fraction of aggregated zervamicin IIA molecules is less than 44-67% depending on the solvent composition. The general usefulness of the method to obtain structural long-range information in a range of several tens of angstroms is demonstrated by comparison with the peptide cluster of trichogin GA IV. PMID:12124850

  13. Label-free Imaging of Arterial Cells and Extracellular Matrix Using a Multimodal CARS Microscope.

    Science.gov (United States)

    Wang, Han-Wei; Le, Thuc T; Cheng, Ji-Xin

    2008-04-01

    A multimodal nonlinear optical imaging system that integrates coherent anti-Stokes Raman scattering (CARS), sum-frequency generation (SFG), and two-photon excitation fluorescence (TPEF) on the same platform was developed and applied to visualize single cells and extracellular matrix in fresh carotid arteries. CARS signals arising from CH(2)-rich membranes allowed visualization of endothelial cells and smooth muscle cells of the arterial wall. Additionally, CARS microscopy allowed vibrational imaging of elastin and collagen fibrils which are also rich in CH(2) bonds. The extracellular matrix organization were further confirmed by TPEF signals arising from elastin's autofluorescence and SFG signals arising from collagen fibrils' non-centrosymmetric structure. Label-free imaging of significant components of arterial tissues suggests the potential application of multimodal nonlinear optical microscopy to monitor onset and progression of arterial diseases.

  14. Introduction to Spin Label Electron Paramagnetic Resonance Spectroscopy of Proteins

    Science.gov (United States)

    Melanson, Michelle; Sood, Abha; Torok, Fanni; Torok, Marianna

    2013-01-01

    An undergraduate laboratory exercise is described to demonstrate the biochemical applications of electron paramagnetic resonance (EPR) spectroscopy. The beta93 cysteine residue of hemoglobin is labeled by the covalent binding of 3-maleimido-proxyl (5-MSL) and 2,2,5,5-tetramethyl-1-oxyl-3-methyl methanethiosulfonate (MTSL), respectively. The excess…

  15. Characterizing Active Pharmaceutical Ingredient Binding to Human Serum Albumin by Spin-Labeling and EPR Spectroscopy.

    Science.gov (United States)

    Hauenschild, Till; Reichenwallner, Jörg; Enkelmann, Volker; Hinderberger, Dariush

    2016-08-26

    Drug binding to human serum albumin (HSA) has been characterized by a spin-labeling and continuous-wave (CW) EPR spectroscopic approach. Specifically, the contribution of functional groups (FGs) in a compound on its albumin-binding capabilities is quantitatively described. Molecules from different drug classes are labeled with EPR-active nitroxide radicals (spin-labeled pharmaceuticals (SLPs)) and in a screening approach CW-EPR spectroscopy is used to investigate HSA binding under physiological conditions and at varying ratios of SLP to protein. Spectral simulations of the CW-EPR spectra allow extraction of association constants (KA ) and the maximum number (n) of binding sites per protein. By comparison of data from 23 SLPs, the mechanisms of drug-protein association and the impact of chemical modifications at individual positions on drug uptake can be rationalized. Furthermore, new drug modifications with predictable protein binding tendency may be envisaged. PMID:27460503

  16. The study of arterial spin labeling perfusion MR imaging in the patients with subclinical hepatic encephalopathy%动脉自旋标记MRI脑血流灌注成像在亚临床期肝性脑病患者的研究

    Institute of Scientific and Technical Information of China (English)

    杨炯; 韩盈; 崔晓明; 李涛; 周卫华; 马林

    2012-01-01

    Objective To investigate the hemodynamic changes in brain basal ganglia in patients with subclinical hepatic encephalopathy (SHE) using arterial spin labeling (ASL) MRI perfusion technique. Methods 16 patients with SHE diagnosed by neuropsychologic tests and 13 cases education-matched healthy volunteers accepted examinations on 1. 5 T GE MR scanner. The scanning protocol included anatomical images and ASL perfusion MR imaging. Using the function tool perfusion software, the parameter maps of cerebral blood flow (CBF) was created. Bilateral head of caudate nucleus, glo-bus pallidus, putamen, thalamus were selected as regions of interest (ROD. Ipsilateral white matter of frontal lobe was used as reference, the ratios of ROI were calculated and compared with those in the control group. Results The CBF ratio for every ROI was higher in SHE patients versus the control. CBF value of right head of caudate nucleus, globus pallidus, putamen, thalamus versus ipsilateral white matter in frontal lobe in SHE patients was 0. 88±0. 17, 1. 01± 0. 06, 0. 96 ± 0.13 and 0. 93 ±0. 10, respectively, CBF value of left ROI was 0. 91 ± 0. 15, 1.00 ± 0.07, 0. 94±0. 12 and 0.97 ± 0. 11, respectively; and CBF value of right ROI in control group was 0. 81 ± 0. 04, 0. 95 ± 0. 04, 0. 88 ± 0. 04 and 0. 90 ± 0. 04, respectively, CBF value of left ROI in control was 0. 81 ± 0.02, 0. 94 ± 0.04, 0. 87±0. 05 and 0.92 ± 0.04, respectively. Conclusion The increasing CBF in basal ganglia could be identified in patients with SHE using ASL MRI perfusion technique. CBF increase was compatible with the opinion that the cerebral blood flow redistributed from cortical areas to basal ganglion structures.%目的 用动脉自旋标记(ASL)MRI灌注成像技术评价亚临床肝性脑病(SHE)患者基底节区的脑血流灌注模式.方法 对16例经神经心理试验诊断为SHE的患者和13例年龄和教育程度相匹配的健康志愿者进行MRI平扫和ASL灌注成像,分别测量双侧

  17. Electron spin resonance of copper labelled myoglobin crystals

    International Nuclear Information System (INIS)

    Single crystals of sperm whale met mioglobin were doped with Cu2+ by immersion in a satured solution of NH3(SO4) containing diluted Cu(SO4). Angular variations of the EPR espectra were measured in the planes: ab, ac* and bc* (c* is an axis perpendicular to the ab plane of the monoclinic crystal). A fitting using a spin Hamiltonian with axial symmetry calculated up to second order gives the EPR hyperfine constants g = (2.328+-0.002), g = (2.069+-0.002), A = (162+-3) gauss and A = (20+-3) gauss. The parallel axis makes an angle of (390 +- 20) with the crystaline b axis. A super hyperfine spectra was evidenciated in a perpendicular direction associated with gxx or gyy. This splitting may be attributed to a spread of a wavefunction of the unpaired electron over one nitrogene of the imidazole ring of the Histidine A10 in Mb: Cu2+

  18. Utility of susceptibility-weighted imaging and arterial spin perfusion imaging in pediatric brain arteriovenous shunting

    Energy Technology Data Exchange (ETDEWEB)

    Nabavizadeh, Seyed Ali; Edgar, J.C.; Vossough, Arastoo [University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2014-10-15

    The objectives of the study are to investigate the application of susceptibility-weighted imaging (SWI) and arterial spin labeling (ASL) imaging in the assessment of shunting and the draining veins in pediatric patients with arteriovenous shunting and compare the utility of SWI and ASL with conventional MR and digital subtraction angiography (DSA). This study is a retrospective study of 19 pediatric patients with arteriovenous shunting on brain MRI who were also evaluated with DSA. We assessed the ability of conventional MRI sequences, susceptibility magnitude images, phase-filtered SWI images, and pulsed ASL images in the detection of arteriovenous (AV) shunting, number of draining veins and drainage pathways in comparison to DSA. The mean number of detected draining veins on DSA (3.63) was significantly higher compared to SWI phase-filtered image (mean = 2.72), susceptibility magnitude image (mean = 2.92), ASL (mean = 1.76) and conventional MRI (2.47) (p < 0.05). Pairwise comparison of DSA difference scores (i.e., difference between MR modalities in the number of missed draining veins) revealed no difference between the MR modalities (p > 0.05). ASL was the only method that correctly identified superficial and deep venous drainage in all patients. Regarding detection of shunting, ASL, SWI phase-filtered, and magnitude images demonstrated shunting in 100, 83, and 84 % of patients, respectively. SWI depicts a higher number of draining vein compared to conventional MR pulse sequences. ASL is a sensitive approach in showing 100 % sensitivity in the detection of AV shunting and in the diagnosis of the pattern of venous drainage. The present findings suggest the added utility of both SWI and ASL in the assessment of AV shunting. (orig.)

  19. Simulation of spin label structure and its implication in molecular characterization

    Science.gov (United States)

    Fajer, Piotr; Fajer, Mikolai; Zawrotny, Michael; Yang, Wei

    2016-01-01

    Interpretation of EPR from spin labels in terms of structure and dynamics requires knowledge of label behavior. General strategies were developed for simulation of labels used in EPR of proteins. The criteria for those simulations are: (a) exhaustive sampling of rotamer space; (b) consensus of results independent of starting points; (c) inclusion of entropy. These criteria are satisfied only when the number of transitions in any dihedral angle exceeds 100 and the simulation maintains thermodynamic equilibrium. Methods such as conventional MD do not efficiently cross energetic barriers, Simulated Annealing, Monte Carlo or popular Rotamer Library methodologies are potential energy based and ignore entropy (in addition to their specific shortcomings: environment fluctuations, fixed environment or electrostatics). Simulated Scaling method, avoids above flaws by modulating the forcefields between 0 (allowing crossing energy barriers) and full potential (sampling minima). Spin label diffuses on this surface while remaining in thermodynamic equilibrium. Simulations show that: (a) single conformation is rare, often there are 2–4 populated rotamers; (b) position of the NO varies up to 16Å. These results illustrate necessity for caution when interpreting EPR signals in terms of molecular structure. For example the 10–16Å distance change in DEER should not be interpreted as a large conformational change, it can well be a flip about Cα -Cβ bond. Rigorous exploration of possible rotamer structures of a spin label is paramount in signal interpretation. We advocate use of bifunctional labels, which motion is restricted 10,000-fold and the NO position is restricted to 2–5Å. PMID:26478501

  20. Dynamic nuclear polarization of membrane proteins: covalently bound spin-labels at protein–protein interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Wylie, Benjamin J. [Columbia University, Department of Chemistry (United States); Dzikovski, Boris G. [Cornell University, National Biomedical Center for Advanced ESR Technology, Department of Chemistry and Chemical Biology (United States); Pawsey, Shane; Caporini, Marc; Rosay, Melanie [Bruker BioSpin Corporation (United States); Freed, Jack H. [Cornell University, National Biomedical Center for Advanced ESR Technology, Department of Chemistry and Chemical Biology (United States); McDermott, Ann E., E-mail: aem5@columbia.edu [Columbia University, Department of Chemistry (United States)

    2015-04-15

    We demonstrate that dynamic nuclear polarization of membrane proteins in lipid bilayers may be achieved using a novel polarizing agent: pairs of spin labels covalently bound to a protein of interest interacting at an intermolecular interaction surface. For gramicidin A, nitroxide tags attached to the N-terminal intermolecular interface region become proximal only when bimolecular channels forms in the membrane. We obtained signal enhancements of sixfold for the dimeric protein. The enhancement effect was comparable to that of a doubly tagged sample of gramicidin C, with intramolecular spin pairs. This approach could be a powerful and selective means for signal enhancement in membrane proteins, and for recognizing intermolecular interfaces.

  1. Arterial spin labelling reveals prolonged arterial arrival time in idiopathic Parkinson's disease

    Directory of Open Access Journals (Sweden)

    Sarah Al-Bachari

    2014-01-01

    A significant (p = 0.005 increase in whole brain averaged baseline AAT was observed in IPD participants (mean ± SD age 1532 ± 138 ms compared to controls (mean ± SD age 1335 ± 165 ms. Voxel-wise analysis revealed this to be widespread across the brain. However, there were no statistically significant differences in white matter lesion score, CBF, or CVR between patients and controls. Regional CBF, but not AAT, in the IPD group was found to correlate positively with Montreal cognitive assessment (MoCA scores. These findings provide further evidence of alterations in NVS in IPD.

  2. Investigation of surface potential asymmetry in phospholipid vesicles by a spin label relaxation method.

    OpenAIRE

    Sundberg, S A; Hubbell, W L

    1986-01-01

    In earlier work, Castle and Hubbell (1976) demonstrated the use of a spin-labeled amphiphile as a probe for the electrostatic potential at the outer surface of charged phospholipid vesicles. In recent experiments, we have shown that the hydrophobic anion tetraphenylboron (TPB) promotes transbilayer migration of the probe molecule. Relaxation data recorded following the rapid mixing of the probe with TPB-containing vesicle samples provides information about the electrostatic potentials at both...

  3. A triarylmethyl spin label for long-range distance measurement at physiological temperatures using T1 relaxation enhancement

    Science.gov (United States)

    Yang, Zhongyu; Bridges, Michael D.; López, Carlos J.; Rogozhnikova, Olga Yu.; Trukhin, Dmitry V.; Brooks, Evan K.; Tormyshev, Victor; Halpern, Howard J.; Hubbell, Wayne L.

    2016-08-01

    Site-directed spin labeling (SDSL) in combination with electron paramagnetic resonance (EPR) spectroscopy has become an important tool for measuring distances in proteins on the order of a few nm. For this purpose pairs of spin labels, most commonly nitroxides, are site-selectively introduced into the protein. Recent efforts to develop new spin labels are focused on tailoring the intrinsic properties of the label to either extend the upper limit of measurable distances at physiological temperature, or to provide a unique spectral lineshape so that selective pairwise distances can be measured in a protein or complex containing multiple spin label species. Triarylmethyl (TAM) radicals are the foundation for a new class of spin labels that promise to provide both capabilities. Here we report a new methanethiosulfonate derivative of a TAM radical that reacts rapidly and selectively with an engineered cysteine residue to generate a TAM containing side chain (TAM1) in high yield. With a TAM1 residue and Cu2+ bound to an engineered Cu2+ binding site, enhanced T1 relaxation of TAM should enable measurement of interspin distances up to 50 Å at physiological temperature. To achieve favorable TAM1-labeled protein concentrations without aggregation, proteins are tethered to a solid support either site-selectively using an unnatural amino acid or via native lysine residues. The methodology is general and readily extendable to complex systems, including membrane proteins.

  4. Selectively dispersed isotope labeling for protein structure determination by magic angle spinning NMR

    Energy Technology Data Exchange (ETDEWEB)

    Eddy, Matthew T. [Massachusetts Institute of Technology, Department of Chemistry (United States); Belenky, Marina [Brandeis University, Department of Chemistry (United States); Sivertsen, Astrid C. [Massachusetts Institute of Technology, Francis Bitter Magnet Laboratory (United States); Griffin, Robert G. [Massachusetts Institute of Technology, Department of Chemistry (United States); Herzfeld, Judith, E-mail: herzfeld@brandeis.edu [Brandeis University, Department of Chemistry (United States)

    2013-10-15

    The power of nuclear magnetic resonance spectroscopy derives from its site-specific access to chemical, structural and dynamic information. However, the corresponding multiplicity of interactions can be difficult to tease apart. Complimentary approaches involve spectral editing on the one hand and selective isotope substitution on the other. Here we present a new 'redox' approach to the latter: acetate is chosen as the sole carbon source for the extreme oxidation numbers of its two carbons. Consistent with conventional anabolic pathways for the amino acids, [1-{sup 13}C] acetate does not label {alpha} carbons, labels other aliphatic carbons and the aromatic carbons very selectively, and labels the carboxyl carbons heavily. The benefits of this labeling scheme are exemplified by magic angle spinning spectra of microcrystalline immunoglobulin binding protein G (GB1): the elimination of most J-couplings and one- and two-bond dipolar couplings provides narrow signals and long-range, intra- and inter-residue, recoupling essential for distance constraints. Inverse redox labeling, from [2-{sup 13}C] acetate, is also expected to be useful: although it retains one-bond couplings in the sidechains, the removal of CA-CO coupling in the backbone should improve the resolution of NCACX spectra.

  5. Technetium-99m labelled macroaggregated albumin arterial catheter perfusion scintigraphy: prediction of gastrointestinal toxicity in hepatic arterial chemotherapy.

    Science.gov (United States)

    Pelosi, E; Masaneo, I; Clara, R; Valetto, M R; Bellò, M; Zanon, C; Chiappino, I; Grosso, M; Mussa, A; Bisi, G

    2000-06-01

    Gastrointestinal toxicity from hepatic arterial infusion (HAI) of floxuridine in patients with liver metastases is probably due to extrahepatic perfusion or to partial escape of the drug from first-pass liver extraction. The aim of this study was to verify the role of technetium-99m-labelled macroaggregated albumin (99mTc-MAA) arterial catheter perfusion scintigraphy at the beginning of each chemotherapy cycle in decreasing or preventing gastrointestinal toxicity. We studied 167 consecutive patients. On the basis of the scintigraphic follow-up and the presence or absence of an intrahepatic arteriovenous shunt (IHAVS), we classified our patients into the following groups: (1) FU+ hepatic distribution pattern (DP), comprising 29 patients with regular scintigraphic follow-up who showed the expected distribution pattern at each control or a distribution pattern with transient alterations (extrahepatic escape) promptly reversed by the replacement of the catheter. Among these 29 patients there was one case of gastrointestinal toxicity. (2) FU- hepatic DP, comprising 128 patients who were evaluated with 99mTc-MAA only at the beginning of the first chemotherapy cycle, showed the expected distribution pattern and underwent HAI with no further scintigraphic evaluation. Among these 128 patients there were 28 cases of gastrointestinal toxicity. (3) FU+ pulmonary DP, comprising three patients with abnormally elevated pulmonary uptake (higher than 5%) and with regular scintigraphic follow-up. There were two cases of gastrointestinal toxicity among these three patients. (4) FU- pulmonary DP, comprising seven patients with abnormally elevated pulmonary uptake and without regular scintigraphic follow-up. There were four cases of gastrointestinal toxicity among these seven patients. The incidence of toxicity was significantly higher in group FU- hepatic DP than in group FU+ hepatic DP (21.9% vs 3.4%, Pscintigraphic follow-up is useful since it is able to promptly diagnose the

  6. Producing Radical-Free Hyperpolarized Perfusion Agents for In Vivo Magnetic Resonance Using Spin-Labeled Thermoresponsive Hydrogel.

    Science.gov (United States)

    Cheng, Tian; Mishkovsky, Mor; Junk, Matthias J N; Münnemann, Kerstin; Comment, Arnaud

    2016-07-01

    Dissolution dynamic nuclear polarization (DNP) provides a way to tremendously improve the sensitivity of nuclear magnetic resonance experiments. Once the spins are hyperpolarized by dissolution DNP, the radicals used as polarizing agents become undesirable since their presence is an additional source of nuclear spin relaxation and their toxicity might be an issue. This study demonstrates the feasibility of preparing a hyperpolarized [1-(13) C]2-methylpropan-2-ol (tert-butanol) solution free of persistent radicals by using spin-labeled thermoresponsive hydrophilic polymer networks as polarizing agents. The hyperpolarized (13) C signal can be detected for up to 5 min before the spins fully relax to their thermal equilibrium. This approach extends the applicability of spin-labeled thermoresponsive hydrogel to the dissolution DNP field and highlights its potential as polarizing agent for preparing neat slowly relaxing contrast agents. The hydrogels are especially suited to hyperpolarize deuterated alcohols which can be used for in vivo perfusion imaging. PMID:27184565

  7. Spin Labeling ESR Investigation of a Role of Humic Acids at Covalent Binding of Xenobiotics to Soil

    Science.gov (United States)

    Aleksandrova, Olga

    2014-05-01

    The environmental risk of organic xenobiotic chemicals released into soils is controlled by their sorption and binding processes. However, the molecular mechanisms of reversible and irreversible interactions of xenobiotics with soil constituents and an influence of humic substances on this interaction are only partly understood. New methods and approaches aimed at understanding of molecular mechanisms in the soil environment and a role of humic substances in the sorption and binding processes are today required to manage and keep the quality of soil used and fertilized in agricultural industry. The paper presents a new approach of using stable ESR spin labels to investigate a role of humic substances in the interactions of organic xenobiotic chemicals with constituents of natural soil via the typical functional groups of xenobiotics, such as Amines. At the experiment, the nitroxide spin labels, such as TEMPO (2,2,6,6-Tetramethylpiperidin-1-oxyl), Amino-TEMPO (4-amino-2,2,6,6-Tetramethylpiperidin-1-oxyl) and Aniline spin labels (2,5,5-Trimethyl-2-(3-aminophenyl)pyrrolidin-1-oxyl), were added to samples of different natural soils, such luvisol, cambisol and chernozem. Amino-TEMPO and Aniline spin labels include the aliphatic amino and aromatic amino functional groups, respectively. A significant broadening of the ESR spectrum of Aniline spin labels incubated in different soils indicated a stable effect of covalent binding of the spin labels to soil constituents via the aromatic amino, whereas the ESR spectra of the other two spin labels were not broadened that pointed at the absence of covalent binding of spin labels via the aliphatic amino. As shown, a part of bound spin labels via the aromatic amino increased with increasing of the concentration of humic acids in soil. The same broadened signals were also be detected with the humic acids extracted from the investigated soils. A strong covalent binding of spin labels to humic substances via the aromatic amines was

  8. Technetium-99m labelled macroaggregated albumin arterial catheter perfusion scintigraphy: prediction of gastrointestinal toxicity in hepatic arterial chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Pelosi, E.; Masaneo, I.; Valetto, M.R.; Bello, M.; Bisi, G. [Department of Nuclear Medicine, University of Turin, Turin (Italy); Clara, R.; Zanon, C.; Chiappino, I.; Mussa, A. [Division of Esophageal and Oncological Surgery, University of Turin, Turin (Italy); Grosso, M. [Division of Radiology, S. Croce e Carle Hospital, Cuneo (Italy)

    2000-06-01

    Gastrointestinal toxicity from hepatic arterial infusion (HAI) of floxuridine in patients with liver metastases is probably due to extrahepatic perfusion or to partial escape of the drug from first-pass liver extraction. The aim of this study was to verify the role of technetium-99m-labelled macroaggregated albumin ({sup 99m}Tc-MAA) arterial catheter perfusion scintigraphy at the beginning of each chemotherapy cycle in decreasing or preventing gastrointestinal toxicity. We studied 167 consecutive patients. On the basis of the scintigraphic follow-up and the presence or absence of an intrahepatic arteriovenous shunt (IHAVS), we classified our patients into the following groups: (1) FU+ hepatic distribution pattern (DP), comprising 29 patients with regular scintigraphic follow-up who showed the expected distribution pattern at each control or a distribution pattern with transient alterations (extrahepatic escape) promptly reversed by the replacement of the catheter. Among these 29 patients there was one case of gastrointestinal toxicity. (2) FU- hepatic DP, comprising 128 patients who were evaluated with {sup 99m}Tc-MAA only at the beginning of the first chemotherapy cycle, showed the expected distribution pattern and underwent HAI with no further scintigraphic evaluation. Among these 128 patients there were 28 cases of gastrointestinal toxicity. (3) FU+ pulmonary DP, comprising three patients with abnormally elevated pulmonary uptake (higher than 5%) and with regular scintigraphic follow-up. There were two cases of gastrointestinal toxicity among these three patients. (4) FU- pulmonary DP, comprising seven patients with abnormally elevated pulmonary uptake and without regular scintigraphic follow-up. There were four cases of gastrointestinal toxicity among these seven patients. The incidence of toxicity was significantly higher in group FU- hepatic DP than in group FU+ hepatic DP (21.9% vs 3.4%, P<0.05). In both the FU+ pulmonary DP and FU- pulmonary DP groups, the

  9. Survival in patients with hepatocellular carcinoma treated with intra-arterial {sup 131}I labelled lipiodol.

    Energy Technology Data Exchange (ETDEWEB)

    Butler, S.P.; Morris, D.L.; Ring, M.T.; King, J.; Parks, S.L.; Glenn, D.W. [St George Hospital, Kogarah, NSW, (Australia). Department of Nuclear Medicine

    1997-09-01

    Full text: The prognosis of untreated hepatocellular carcinoma (HCC) is dismal with a median survival of less than two months having been reported. {sup 131}l labelled Lipiodol as a treatment for hepatocellular carcinoma (HCC) has been shown to be as efficacious as intraarterial chemotherapy but with less toxicity than chemotherapy. 23 patients (19 men and four women, mean age 69 years, range 28 to 80 years) with unresectable Okuda Stage I (n = 23) or 11 (n = 2) HCC were treated over a three-year period. All patients had biopsy proved HCC and had not received any prior therapy. Before therapy, all patients underwent CT scans of abdomen and thorax and scintigraphic bone scans to exclude extrahepatic disease. Further, CT scanning of the liver was performed following the hepatic artery injection of unlabelled Lipiodol to ensure that the HCC was Lipiodol avid. 1 GBq of {sup 131}l labelled Lipiodol was injected into the hepatic artery followed by CT liver scanning at day 1 and day 60 to calculate tumour response. Whole body scintigraphic scanning was performed on days 1 and 21 for dosimetry calculations. Ten patients had a second dose of {sup 131}l Lipiodol due either increasing serum alpha feto-protein levels and/or tumour progression on CT scanning. Minimal toxicity was seen with this dose regime. Survival time was estimated from the time of treatment by the Kaplan-Meier method. For Okuda I, the median survival length was 12 months with actuarial survival rates of 91 per cent, 65 per cent, 59 per cent and 20 per cent at 3,6,9,12 and 24 months respectively. All Okuda II patients died within five months. Iodine-131 Lipiodol therapy is well tolerated and may prolong survival in certain HCC patients.

  10. Spatial arrangement of rhodopsin in retinal rod outer segment membranes studied by spin-labeling and pulsed electron double resonance

    Energy Technology Data Exchange (ETDEWEB)

    Yasuda, Satoshi [Department of Biological Sciences, Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Department of Space and Earth Sciences, Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Hara, Hideyuki [Bruker Biospin, Yokohama, Kanagawa 215-0022 (Japan); Tokunaga, Fumio [Department of Space and Earth Sciences, Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Arata, Toshiaki, E-mail: arata@bio.sci.osaka-u.ac.jp [Department of Biological Sciences, Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Department of Space and Earth Sciences, Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan)

    2012-08-24

    Highlights: Black-Right-Pointing-Pointer Use of spin labeling and PELDOR to measure inter-rhodopsin distance in ROS. Black-Right-Pointing-Pointer Strong decay of PELDOR signal indicated a high density (mM range) of rhodopsin. Black-Right-Pointing-Pointer The decay was modeled by rhodopsin monomers dispersed in a planar membrane. -- Abstract: We have determined the spatial arrangement of rhodopsin in the retinal rod outer segment (ROS) membrane by measuring the distances between rhodopsin molecules in which native cysteines were spin-labeled at {approx}1.0 mol/mol rhodopsin. The echo modulation decay of pulsed electron double resonance (PELDOR) from spin-labeled ROS curved slightly with strong background decay. This indicated that the rhodopsin was densely packed in the retina and that the rhodopsin molecules were not aligned well. The curve was simulated by a model in which rhodopsin is distributed randomly as monomers in a planar membrane.

  11. mtsslSuite: In silico spin labelling, trilateration and distance-constrained rigid body docking in PyMOL

    Science.gov (United States)

    Hagelueken, Gregor; Abdullin, Dinar; Ward, Richard; Schiemann, Olav

    2013-10-01

    Nanometer distance measurements based on electron paramagnetic resonance methods in combination with site-directed spin labelling are powerful tools for the structural analysis of macromolecules. The software package mtsslSuite provides scientists with a set of tools for the translation of experimental distance distributions into structural information. The package is based on the previously published mtsslWizard software for in silico spin labelling. The mtsslSuite includes a new version of MtsslWizard that has improved performance and now includes additional types of spin labels. Moreover, it contains applications for the trilateration of paramagnetic centres in biomolecules and for rigid-body docking of subdomains of macromolecular complexes. The mtsslSuite is tested on a number of challenging test cases and its strengths and weaknesses are evaluated.

  12. EPR Distance Measurements in Native Proteins with Genetically Encoded Spin Labels.

    Science.gov (United States)

    Schmidt, Moritz J; Fedoseev, Artem; Bücker, Dennis; Borbas, Julia; Peter, Christine; Drescher, Malte; Summerer, Daniel

    2015-12-18

    The genetic encoding of nitroxide amino acids in combination with electron paramagnetic resonance (EPR) distance measurements enables precise structural studies of native proteins, i.e. without the need for mutations to create unique reactive sites for chemical labeling and thus with minimal structural perturbation. We here report on in vitro DEER measurements in native E. coli thioredoxin (TRX) that establish the nitroxide amino acid SLK-1 as a spectroscopic probe that reports distances and conformational flexibilities in the enzyme with nonmutated catalytic centers that are not accessible by the use of the traditional methanethiosulfonate spin label (MTSSL). We generated a rotamer library for SLK-1 that in combination with molecular dynamics (MD) simulation enables predictions of distance distributions between two SLK-1 labels incorporated into a target protein. Toward a routine use of SLK-1 for EPR distance measurements in proteins and the advancement of the approach to intracellular environments, we study the stability of SLK-1 in E. coli cultures and lysates and establish guidelines for protein expression and purification that offer maximal nitroxide stability. These advancements and insights provide new perspectives for facile structural studies of native, endogenous proteins by EPR distance measurements.

  13. Gd(3+) Spin Labels Report the Conformation and Solvent Accessibility of Solution and Vesicle-Bound Melittin.

    Science.gov (United States)

    Manukovsky, Nurit; Frydman, Veronica; Goldfarb, Daniella

    2015-10-29

    Although Gd(3+)-based spin labels have been shown to be an alternative to nitroxides for double electron-electron resonance (DEER) distance measurements at high fields, their ability to provide solvent accessibility information, as nitroxides do, has not been explored. In addition, the effect of the label type on the measured distance distribution has not been sufficiently characterized. In this work, we extended the applicability of Gd(3+) spin labels to solvent accessibility measurements on a peptide in model membranes, namely, large unilamellar vesicles (LUVs) using W-band (2)H Mims electron-nuclear double resonance (ENDOR) and electron spin echo envelope modulation (ESEEM) techniques and Gd(3+)-ADO3A-labeled melittin. In addition, we carried out Gd(3+)-Gd(3+) DEER distance measurements to probe the peptide conformation in solution and when bound to LUVs. A comparison with earlier results reported for the same system with nitroxide labels shows that, although in both cases the peptide binds parallel to the membrane surface, the Gd(3+)-ADO3A label tends to protrude from the membrane into the solvent, whereas the nitroxide does the opposite. This can be explained on the basis of the hydrophilicity of the Gd(3+)-ADO3A labels in contrast with the hydrophobicity of nitroxides. The distance distributions obtained from different labels are accordingly different, with the Gd(3+)-ADO3A yielding consistently broader distributions. These discrepancies are most pronounced when the peptide termini are labeled, which implies that such labeling positions may be inadvisible. PMID:26001213

  14. Luminescence of the nitronyl nitroxide radical group in a spin-labelled pyrazolylquinoline

    International Nuclear Information System (INIS)

    The synthesis, structure and photoluminescence of a group of substituted 2-pyrazolylquinolines, including a spin-labelled derivative, are described. A comparative study of photoluminescence from the synthesized compounds demonstrates that introduction of a nitronyl nitroxide radical group results not only in the expected reduction in photoluminescence from the pyrazolylquinoline moiety, but also gives rise to a new red photoluminescence band (maximum at 692 nm in acetonitrile) from the radical fragment. -- Highlights: • The introduction of nitronyl nitroxide radical in 2-pyrazolylquinolines gives rise to new luminescence band at 692 nm. • The decrease of pyrazolylquinoline luminescence at 390 nm can be explained by intramolecular energy transfer to π-system of radical fragment. • Low quantum yield of 692 nm luminescence is determined by high rate constant of radiationless transition

  15. Site-Directed Spin-Labeling of Nucleic Acids by Click Chemistry. Detection of Abasic Sites in Duplex DNA by EPR Spectroscopy

    DEFF Research Database (Denmark)

    Sigurdsson, Snorri; Vogel, Stefan; Shelke, Sandip;

    2010-01-01

    This paper describes a spin label that can detect and identify local structural deformations in duplex DNA, in particular abasic sites. The spin label was incorporated into DNA by a new postsynthetic approach using click-chemistry on a solid support, which simplified both the synthesis and...

  16. Genetic Incorporation of the Unnatural Amino Acid p-Acetyl Phenylalanine into Proteins for Site-Directed Spin Labeling.

    Science.gov (United States)

    Evans, Eric G B; Millhauser, Glenn L

    2015-01-01

    Site-directed spin labeling (SDSL) is a powerful tool for the characterization of protein structure and dynamics; however, its application in many systems is hampered by the reliance on unique and benign cysteine substitutions for the site-specific attachment of the spin label. An elegant solution to this problem involves the use of genetically encoded unnatural amino acids (UAAs) containing reactive functional groups that are chemically orthogonal to those of the 20 amino acids found naturally in proteins. These unique functional groups can then be selectively reacted with an appropriately functionalized spin probe. In this chapter, we detail the genetic incorporation of the ketone-bearing amino acid p-acetyl phenylalanine (pAcPhe) into recombinant proteins expressed in E. coli. Incorporation of pAcPhe is followed by chemoselective reaction of the ketone side chain with a hydroxylamine-functionalized nitroxide to afford the spin-labeled side chain "K1," and we present two protocols for successful K1 labeling of proteins bearing site-specific pAcPhe. We outline the basic requirements for pAcPhe incorporation and labeling, with an emphasis on practical aspects that must be considered by the researcher if high yields of UAA incorporation and efficient labeling reactions are to be achieved. To this end, we highlight recent advances that have led to increased yields of pAcPhe incorporation, and discuss the use of aniline-based catalysts allowing for facile conjugation of the hydroxylamine spin label under mild reaction conditions. To illustrate the utility of K1 labeling in proteins where traditional cysteine-based SDSL methods are problematic, we site-specifically K1 label the cellular prion protein at two positions in the C-terminal domain and determine the interspin distance using double electron-electron resonance EPR. Recent advances in UAA incorporation and ketone-based bioconjugation, in combination with the commercial availability of all requisite reagents

  17. Genetic Incorporation of the Unnatural Amino Acid p-Acetyl Phenylalanine into Proteins for Site-Directed Spin Labeling

    Science.gov (United States)

    Evans, Eric G.B.; Millhauser, Glenn L.

    2016-01-01

    Site-directed spin labeling (SDSL) is a powerful tool for the characterization of protein structure and dynamics; however, its application in many systems is hampered by the reliance on unique and benign cysteine substitutions for the site-specific attachment of the spin label. An elegant solution to this problem involves the use of genetically encoded unnatural amino acids (UAAs) containing reactive functional groups that are chemically orthogonal to those of the 20 amino acids found naturally in proteins. These unique functional groups can then be selectively reacted with an appropriately functionalized spin probe. In this chapter, we detail the genetic incorporation of the ketone-bearing amino acid p-acetyl phenylalanine (pAcPhe) into recombinant proteins expressed in E. coli. Incorporation of pAcPhe is followed by chemoselective reaction of the ketone side chain with a hydroxylamine-functionalized nitroxide to afford the spin-labeled side chain “K1,” and we present two protocols for successful K1 labeling of proteins bearing site-specific pAcPhe. We outline the basic requirements for pAcPhe incorporation and labeling, with an emphasis on practical aspects that must be considered by the researcher if high yields of UAA incorporation and efficient labeling reactions are to be achieved. To this end, we highlight recent advances that have led to increased yields of pAcPhe incorporation, and discuss the use of aniline-based catalysts allowing for facile conjugation of the hydroxylamine spin label under mild reaction conditions. To illustrate the utility of K1 labeling in proteins where traditional cysteine-based SDSL methods are problematic, we site-specifically K1 label the cellular prion protein at two positions in the C-terminal domain and determine the interspin distance using double electron–electron resonance EPR. Recent advances in UAA incorporation and ketone-based bioconjugation, in combination with the commercial availability of all requisite

  18. Integrated analysis of the conformation of a protein-linked spin label by crystallography, EPR and NMR spectroscopy

    International Nuclear Information System (INIS)

    Long-range structural information derived from paramagnetic relaxation enhancement observed in the presence of a paramagnetic nitroxide radical is highly useful for structural characterization of globular, modular and intrinsically disordered proteins, as well as protein–protein and protein-DNA complexes. Here we characterized the conformation of a spin-label attached to the homodimeric protein CylR2 using a combination of X-ray crystallography, electron paramagnetic resonance (EPR) and NMR spectroscopy. Close agreement was found between the conformation of the spin label observed in the crystal structure with interspin distances measured by EPR and signal broadening in NMR spectra, suggesting that the conformation seen in the crystal structure is also preferred in solution. In contrast, conformations of the spin label observed in crystal structures of T4 lysozyme are not in agreement with the paramagnetic relaxation enhancement observed for spin-labeled CylR2 in solution. Our data demonstrate that accurate positioning of the paramagnetic center is essential for high-resolution structure determination.

  19. Use of spin labels to study membrane proteins by high-frequency electron nuclear double resonance spectroscopy

    NARCIS (Netherlands)

    Orlinkskii, S.B.; Borovykh, I.V.; Zielke, V.; Steinhoff, H.J.

    2007-01-01

    The applicability of spin labels to study membrane proteins by high-frequency electron nuclear double resonance spectroscopy is demonstrated. With the use of bacteriorhodopsin embedded in a lipid membrane as an example, the spectra of protons of neighboring amino acids are recorded, electric field g

  20. Conformational change in full-length mouse prion: A site-directed spin-labeling study

    International Nuclear Information System (INIS)

    The structure of the mouse prion (moPrP) was studied using site-directed spin-labeling electron spin resonance (SDSL-ESR). Since a previous NMR study by Hornemanna et al., [Hornemanna, Korthb, Oeschb, Rieka, Widera, Wuethricha, Glockshubera, Recombinant full-length murine prion protein, mPrP (23-231): purification and spectroscopic characterization, FEBS Lett. 413 (1997) 277-281] has indicated that N96, D143, and T189 in moPrP are localized in a Cu2+ binding region, Helix1 and Helix2, respectively, three recombinant moPrP mutations (N96C, D143C, and T189C) were expressed in an Escherichia coli system, and then refolded by dialysis under low pH and purified by reverse-phase HPLC. By using the preparation, we succeeded in preserving a target cystein residue without alteration of the α-helix structure of moPrP and were able to apply SDSL-ESR with a methane thiosulfonate spin label to the full-length prion protein. The rotational correlation times (τ) of 1.1, 3.3, and 4.8 ns were evaluated from the X-band ESR spectra at pH 7.4 and 20 deg C for N96R1, D143R1, and T189R1, respectively. τ reflects the fact that the Cu2+ binding region is more flexible than Helix1 or Helix2. ESR spectra recorded at various temperatures revealed two phases together with a transition point at around 20 deg C in D143R1 and T189R1, but not in N96R1. With the variation of pH from 4.0 to 7.8, ESR spectra of T189R1 at 20 deg C showed a gradual increase of τ from 2.9 to 4.8 ns. On the other hand, the pH-dependent conformational changes in N96R1 and D143R1 were negligible. These results indicated that T189 located in Helix2 possessed a structure sensitive to physiological pH changes; simultaneously, N96 in the Cu2+ binding region and D143 in Helix1 were conserved

  1. Long-term MRI tracking of dual-labeled adipose-derived stem cells homing into mouse carotid artery injury

    Directory of Open Access Journals (Sweden)

    Qin JB

    2012-10-01

    Full Text Available Jin-Bao Qin,1,5,* Kang-An Li,2,* Xiang-Xiang Li,1,5 Qing-Song Xie,3 Jia-Ying Lin,4 Kai-Chuang Ye,1,5 Mi-Er Jiang,1,5 Gui-Xiang Zhang,2 Xin-Wu Lu1,51Department of Vascular Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University, School of Medicine, 2Department of Radiology, Shanghai First People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 3Department of Neurosurgery, Cixi Municipal People's Hospital, Zhejiang Province, China; 4Clinic for Gynecology, Charite-Universitatsmedizin Berlin, Berlin, Germany; 5Vascular Center, Shanghai Jiao Tong University, Shanghai, China*These two authors contributed equally to this workBackground: Stem cell therapy has shown great promise for regenerative repair of injured or diseased tissues. Adipose-derived stem cells (ADSCs have become increasingly attractive candidates for cellular therapy. Magnetic resonance imaging has been proven to be effective in tracking magnetic-labeled cells and evaluating their clinical relevance after cell transplantation. This study investigated the feasibility of imaging green fluorescent protein-expressing ADSCs (GFP-ADSCs labeled with superparamagnetic iron oxide particles, and tracked them in vivo with noninvasive magnetic resonance imaging after cell transplantation in a model of mouse carotid artery injury.Methods: GFP-ADSCs were isolated from the adipose tissues of GFP mice and labeled with superparamagnetic iron oxide particles. Intracellular stability, proliferation, and viability of the labeled cells were evaluated in vitro. Next, the cells were transplanted into a mouse carotid artery injury model. Clinical 3 T magnetic resonance imaging was performed immediately before and 1, 3, 7, 14, 21, and 30 days after cell transplantation. Prussian blue staining and histological analysis were performed 7 and 30 days after transplantation.Results: GFP-ADSCs were found to be efficiently labeled with superparamagnetic iron oxide

  2. Orientation and lipid-peptide interactions of gramicidin A in lipid membranes: Polarized attenuated total reflection infrared spectroscopy and spin-label electron spin resonance

    OpenAIRE

    Kota, Z.; Pali, T.; Marsh, D.

    2004-01-01

    Gramicidin A was incorporated at a peptide/lipid ratio of 1:10 mol/mol in aligned bilayers of dimyristoyl phosphatidylcholine (DMPC), phosphatidylserine (DMPS), phosphatidylglycerol (DMPG), and phosphatidylethanolamine (DMPE), from trifluoroethanol. Orientations of the peptide and lipid chains were determined by polarized attenuated total reflection infrared spectroscopy. Lipid-peptide interactions with gramicidin A in DMPC bilayers were studied with different spin-labeled lipid species by us...

  3. Communication: Orientational self-ordering of spin-labeled cholesterol analogs in lipid bilayers in diluted conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kardash, Maria E.; Dzuba, Sergei A., E-mail: dzuba@kinetics.nsc.ru [Voevodsky Institute of Chemical Kinetics and Combustion, 630090 Novosibirsk, Russia, and Novosibirsk State University, 630090 Novosibirsk (Russian Federation)

    2014-12-07

    Lipid-cholesterol interactions are responsible for different properties of biological membranes including those determining formation in the membrane of spatial inhomogeneities (lipid rafts). To get new information on these interactions, electron spin echo (ESE) spectroscopy, which is a pulsed version of electron paramagnetic resonance (EPR), was applied to study 3β-doxyl-5α-cholestane (DCh), a spin-labeled analog of cholesterol, in phospholipid bilayer consisted of equimolecular mixture of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine and 1,2-dioleoyl-sn-glycero-3-phosphocholine. DCh concentration in the bilayer was between 0.1 mol.% and 4 mol.%. For comparison, a reference system containing a spin-labeled 5-doxyl-stearic acid (5-DSA) instead of DCh was studied as well. The effects of “instantaneous diffusion” in ESE decay and in echo-detected (ED) EPR spectra were explored for both systems. The reference system showed good agreement with the theoretical prediction for the model of spin labels of randomly distributed orientations, but the DCh system demonstrated remarkably smaller effects. The results were explained by assuming that neighboring DCh molecules are oriented in a correlative way. However, this correlation does not imply the formation of clusters of cholesterol molecules, because conventional continuous wave EPR spectra did not show the typical broadening due to aggregation of spin labels and the observed ESE decay was not faster than in the reference system. So the obtained data evidence that cholesterol molecules at low concentrations in biological membranes can interact via large distances of several nanometers which results in their orientational self-ordering.

  4. Communication: Orientational self-ordering of spin-labeled cholesterol analogs in lipid bilayers in diluted conditions

    Science.gov (United States)

    Kardash, Maria E.; Dzuba, Sergei A.

    2014-12-01

    Lipid-cholesterol interactions are responsible for different properties of biological membranes including those determining formation in the membrane of spatial inhomogeneities (lipid rafts). To get new information on these interactions, electron spin echo (ESE) spectroscopy, which is a pulsed version of electron paramagnetic resonance (EPR), was applied to study 3β-doxyl-5α-cholestane (DCh), a spin-labeled analog of cholesterol, in phospholipid bilayer consisted of equimolecular mixture of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine and 1,2-dioleoyl-sn-glycero-3-phosphocholine. DCh concentration in the bilayer was between 0.1 mol.% and 4 mol.%. For comparison, a reference system containing a spin-labeled 5-doxyl-stearic acid (5-DSA) instead of DCh was studied as well. The effects of "instantaneous diffusion" in ESE decay and in echo-detected (ED) EPR spectra were explored for both systems. The reference system showed good agreement with the theoretical prediction for the model of spin labels of randomly distributed orientations, but the DCh system demonstrated remarkably smaller effects. The results were explained by assuming that neighboring DCh molecules are oriented in a correlative way. However, this correlation does not imply the formation of clusters of cholesterol molecules, because conventional continuous wave EPR spectra did not show the typical broadening due to aggregation of spin labels and the observed ESE decay was not faster than in the reference system. So the obtained data evidence that cholesterol molecules at low concentrations in biological membranes can interact via large distances of several nanometers which results in their orientational self-ordering.

  5. Spin labeling and Double Electron-Electron Resonance (DEER) to Deconstruct Conformational Ensembles of HIV Protease

    Science.gov (United States)

    Casey, Thomas M.; Fanucci, Gail E.

    2016-01-01

    An understanding of macromolecular conformational equilibrium in biological systems is oftentimes essential to understand function, dysfunction, and disease. For the past few years, our lab has been utilizing site-directed spin labeling (SDSL), coupled with electron paramagnetic resonance (EPR) spectroscopy, to characterize the conformational ensemble and ligand-induced conformational shifts of HIV-1 protease (HIV-1PR). The biomedical importance of characterizing the fractional occupancy of states within the conformational ensemble critically impacts our hypothesis of a conformational selection mechanism of drug-resistance evolution in HIV-1PR. The purpose of the following chapter is to give a timeline perspective of our SDSL EPR approach to characterizing conformational sampling of HIV-1PR. We provide detailed instructions for the procedure utilized in analyzing distance profiles for HIV-1PR obtained from pulsed electron–electron double resonance (PELDOR). Specifically, we employ a version of PELDOR known as double electron–electron resonance (DEER). Data are processed with the software package “DeerAnalysis” (http://www.epr.ethz.ch/software), which implements Tikhonov regularization (TKR), to generate a distance profile from electron spin-echo amplitude modulations. We assign meaning to resultant distance profiles based upon a conformational sampling model, which is described herein. The TKR distance profiles are reconstructed with a linear combination of Gaussian functions, which is then statistically analyzed. In general, DEER has proven powerful for observing structural ensembles in proteins and, more recently, nucleic acids. Our goal is to present our advances in order to aid readers in similar applications. PMID:26477251

  6. Site directed spin labeling studies of Escherichia coli dihydroorotate dehydrogenase N-terminal extension

    Energy Technology Data Exchange (ETDEWEB)

    Couto, Sheila G. [Instituto de Fisica de Sao Carlos, Universidade de Sao Paulo, Av. Trabalhador Sao-carlense 400, C.P. 369, 13560-970, Sao Carlos, SP (Brazil); Grupo de Biofisica e Fisica Aplicada a Medicina, Instituto de Fisica, Universidade Federal de Goias, Campus Samambaia, C.P. 131, 74001-970, Goiania, GO (Brazil); Cristina Nonato, M. [Laboratorio de Cristalografia de Proteinas, Faculdade de Ciencias Farmaceuticas de Ribeirao Preto, Universidade de Sao Paulo, Av. do Cafe S/N, 14040-903, Ribeirao Preto, SP (Brazil); Costa-Filho, Antonio J., E-mail: ajcosta@ffclrp.usp.br [Instituto de Fisica de Sao Carlos, Universidade de Sao Paulo, Av. Trabalhador Sao-carlense 400, C.P. 369, 13560-970, Sao Carlos, SP (Brazil); Departamento de Fisica, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Av. Bandeirantes 3900, 14040-901, Ribeirao Preto, SP (Brazil)

    2011-10-28

    Highlights: Black-Right-Pointing-Pointer EcDHODH is a membrane-associated enzyme and a promising target for drug design. Black-Right-Pointing-Pointer Enzyme's N-terminal extension is responsible for membrane association. Black-Right-Pointing-Pointer N-terminal works as a molecular lid regulating access to the protein interior. -- Abstract: Dihydroorotate dehydrogenases (DHODHs) are enzymes that catalyze the fourth step of the de novo synthesis of pyrimidine nucleotides. In this reaction, DHODH converts dihydroorotate to orotate, using a flavine mononucleotide as a cofactor. Since the synthesis of nucleotides has different pathways in mammals as compared to parasites, DHODH has gained much attention as a promising target for drug design. Escherichia coli DHODH (EcDHODH) is a family 2 DHODH that interacts with cell membranes in order to promote catalysis. The membrane association is supposedly made via an extension found in the enzyme's N-terminal. In the present work, we used site directed spin labeling (SDSL) to specifically place a magnetic probe at positions 2, 5, 19, and 21 within the N-terminal and thus monitor, by using Electron Spin Resonance (ESR), dynamics and structural changes in this region in the presence of a membrane model system. Overall, our ESR spectra show that the N-terminal indeed binds to membranes and that it experiences a somewhat high flexibility that could be related to the role of this region as a molecular lid controlling the entrance of the enzyme's active site and thus allowing the enzyme to give access to quinones that are dispersed in the membrane and that are necessary for the catalysis.

  7. Impact of menaquinone-4 supplementation on coronary artery calcification and arterial stiffness: an open label single arm study

    OpenAIRE

    Ikari, Yuji; Torii, Sho; Shioi, Atsushi; Okano, Toshio

    2016-01-01

    Background Dietary intake of vitamin K has been reported to reduce coronary artery calcification (CAC) and cardiovascular events. However, it is unknown whether supplemental menaquinone (MK)-4 can reduce CAC or arterial stiffness. To study the effect of MK-4 supplementation on CAC and brachial ankle pulse wave velocity (baPWV). Methods This study is a single arm design to take 45 mg/day MK-4 daily as a therapeutic drug for 1 year. Primary endpoint was CAC score determined using 64-slice multi...

  8. A novel electron paramagnetic resonance spin label and its application to study the cross-bridge cycle.

    OpenAIRE

    Raucher, D; Fajer, E A; Sár, C; Hideg, K; Zhao, Y.; Kawai, M; Fajer, P G

    1995-01-01

    We have used a novel alpha-iodoketone spin-label (IKSL) to study myosin head orientation and cross-bridge dynamics in the putative pre-powerstroke state. Possible perturbation of the cross-bridge cycle by the label was assayed by the sinusoidal analysis method (Kawai and Brandt, 1980; Kawai and Zhao, 1993), which determines the rate constants of the elementary steps in the cycle. A comparison of the rates obtained from unlabeled and IKSL fibers revealed small (10-20%) changes in the ATP hydro...

  9. Site Directed Spin Labeling and EPR Spectroscopic Studies of Pentameric Ligand-Gated Ion Channels.

    Science.gov (United States)

    Basak, Sandip; Chatterjee, Soumili; Chakrapani, Sudha

    2016-01-01

    Ion channel gating is a stimulus-driven orchestration of protein motions that leads to transitions between closed, open, and desensitized states. Fundamental to these transitions is the intrinsic flexibility of the protein, which is critically modulated by membrane lipid-composition. To better understand the structural basis of channel function, it is necessary to study protein dynamics in a physiological membrane environment. Electron Paramagnetic Resonance (EPR) spectroscopy is an important tool to characterize conformational transitions between functional states. In comparison to NMR and X-ray crystallography, the information obtained from EPR is intrinsically of lower resolution. However, unlike in other techniques, in EPR there is no upper-limit to the molecular weight of the protein, the sample requirements are significantly lower, and more importantly the protein is not constrained by the crystal lattice forces. Therefore, EPR is uniquely suited for studying large protein complexes and proteins in reconstituted systems. In this article, we will discuss general protocols for site-directed spin labeling and membrane reconstitution using a prokaryotic proton-gated pentameric Ligand-Gated Ion Channel (pLGIC) from Gloeobacter violaceus (GLIC) as an example. A combination of steady-state Continuous Wave (CW) and Pulsed (Double Electron Electron Resonance-DEER) EPR approaches will be described that will enable a complete quantitative characterization of channel dynamics. PMID:27403967

  10. Use of spin labels to evaluate effects of cold shock and osmolality on sperm

    Energy Technology Data Exchange (ETDEWEB)

    Hammerstedt, R.H.; Keith, A.D.; Snipes, W.; Amann, R.P.; Arruda, D.; Griel, L.C. Jr.

    1978-05-01

    Spin labels were used to evaluate the effects of butylated hydroxytoluene (BHT), rapid cooling to 0/sup 0/C and osmolality on the integrity of sperm membranes. In vitro incubation of rabbit sperm with 0.5 mM BHT prior to artificial insemination did not alter the fertilizing ability of the sperm. Sperm from 6 species were ranked in terms of susceptibility to membrane damage caused by rapid cooling to 0/sup 0/C. The integrity of bull and ram sperm membranes was destroyed by the rapid cooling; BHT protected membranes of these spermatozoa from cold-induced lysis. Boar sperm membranes were porous after rapid cooling and BHT did not prevent this membrane damage. Membranes of rabbit and rooster sperm were not damaged by rapid cooling to 0/sup 0/C. Stallion sperm could not be analyzed because their membranes were altered by addition of reagents necessary to use the technique. The responses of bull, ram and rabbit sperm membranes to hyper- and hypo-osmotic conditions were determined. Hypotonic treatment (less than 200 mOsm) resulted in a 50 percent expansion of the volume of the aqueous compartment of sperm while hypertonic (700 mOsm) conditions compressed the volume of the aqueous compartment to 25 to 30 percent of the volume measured at 300 mOsm. Bull sperm, but not rabbit or ram sperm, responded as ''perfect osmometers'' between 300 and 700 mOsm.

  11. Structure and dynamics of spin-labeled insulin entrapped in a silica matrix by the sol-gel method.

    Science.gov (United States)

    Vanea, E; Gruian, C; Rickert, C; Steinhoff, H-J; Simon, V

    2013-08-12

    The structure and conformational dynamics of insulin entrapped into a silica matrix was monitored during the sol to maturated-gel transition by electron paramagnetic resonance (EPR) spectroscopy. Insulin was successfully spin-labeled with iodoacetamide and the bifunctional nitroxide reagent HO-1944. Room temperature continuous wave (cw) EPR spectra of insulin were recorded to assess the mobility of the attached spin labels. Insulin conformation and its distribution within the silica matrix were studied using double electron-electron resonance (DEER) and low-temperature cw-EPR. A porous oxide matrix seems to form around insulin molecules with pore diameters in the order of a few nanometers. Secondary structure of the encapsulated insulin investigated by Fourier transform infrared spectroscopy proved a high structural integrity of insulin even in the dried silica matrix. The results show that silica encapsulation can be used as a powerful tool to effectively isolate and functionally preserve biomolecules during preparation, storage, and release.

  12. Effects of AMPPNP on the orientation and rotational dynamics of spin-labeled muscle cross-bridges.

    OpenAIRE

    Fajer, P G; Fajer, E A; Brunsvold, N J; Thomas, D. D.

    1988-01-01

    We have used electron paramagnetic resonance (EPR) to investigate the orientation, rotational motion, and actin-binding properties of rabbit psoas muscle cross-bridges in the presence of the nonhydrolyzable nucleotide analogue, 5'-adenylylimido-diphosphate (AMPPNP). This analogue is known to decrease muscle tension without affecting its stiffness, suggesting an attached cross-bridge state different from rigor. We spin-labeled the SH1 groups on myosin heads and performed conventional EPR to ob...

  13. Renal arterial spin labeling magnetic resonance imaging in normal adults:a study with a 3.0 T scanner%3.0T磁共振动脉自旋标记技术在正常成人肾脏检查中的应用

    Institute of Scientific and Technical Information of China (English)

    张帆; 张雪林; 杨立; 沈洁; 高伟

    2013-01-01

    目的分析单次激发快速自旋回波-流动敏感反转恢复序列(SSFSE-FAIR)与平面回波-流动敏感反转恢复序列(EPI-FAIR)所测量的健康肾脏的相对血流量值(rBFV),评价两种动脉自旋标记(ASL)序列在正常肾脏检查中的应用价值。方法前瞻性分析40例符合纳入标准的受试者的rBFV。采用3.0T磁共振扫描仪扫描。按3种方式采集图像:EPI-FAIR屏气法、SSFSE-FAIR屏气法及SSFSE-FAIR自由呼吸法。结果SSFSE-FAIR自由呼吸法可定量区分肾脏皮髓质。皮质rBFV:111.48±9.23;髓质rBFV:94.98±3.38;SSFSE-FAIR屏气法及EPI-FAIR不能定量区分肾脏皮髓质。EPI-FAIR皮髓平均rBFV为178.50±17.17,95%置信区间:167.59~189.41。结论 SSFSE-FAIR屏气法及EPI-FAIR空间分辨率低,无法区分肾脏皮髓质,可粗略评价肾脏灌注情况。SSFSE-FAIR图像空间分辨率较高,可区分肾脏皮髓质结构,可初步评判肾脏皮髓质的灌注状态。%Objective To analyze the renal relative blood flow value (rBFV) and image quality in normal adults using single-shot fast spin echo, flow sensitive invention recovery (SSFSE-FAIR) magnetic resonance (MR) sequence and echo planar imaging, and flow sensitive invention recovery (EPI-FAIR) MR sequence, and assess its value for clinical application in routine renal examination. Methods Forty volunteers (25 male and 15 female adults, aged 30 to 62 years) with normal renal function were included in this prospective study. All the subjects underwent 3.0 Tesla MR scanning using 3 MR scan modes, namely breath-holding EPI-FAIR, breath-holding SSFSE-FAIR and free breathing SSFSE-FAIR. Results SSFSE-FAIR without breath-holding was capable of differentiating the renal cortex and medulla with the corresponding rBFVs of 111.48 ± 9.23 and 94.98 ± 3.38, respectively. Breath-holding SSFSE-FAIR and EPI-FAIR failed to distinguish the borders of the renal cortex and medulla. The EPI-FAIR rBFV of mixed

  14. Use of paramagnetic chelated metal derivatives of polysaccharides and spin-labeled polysaccharides as contrast agents in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bligh, S.W.; Harding, C.T.; Sadler, P.J.; Bulman, R.A.; Bydder, G.M.; Pennock, J.M.; Kelly, J.D.; Latham, I.A.; Marriott, J.A. (Department of Chemistry, Birkbeck College, London (England))

    1991-02-01

    Soluble and insoluble polysaccharides were derivatized with diethylenetriaminepentaacetic acid (DTPA) and/or spin-labeled with 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO). Polysaccharides derivatized with DTPA were prepared via cyanogen bromide activation, coupling to a diamine linker, and to DTPA anhydride. Spin-labeled polysaccharides were also prepared via cyanogen bromide activation. The extent of derivatization for dextran (18 kDa) was about 120 glucose units per DTPA, and for cellulose and starch about 15-30 units per DTPA. For spin-labeled polysaccharides, the average loading ranged from 1 nitroxide per 16 glucose units for starch to 181 for dextran (82 kDa). These derivatized paramagnetic polysaccharides were shown to be more effective relaxants than the small paramagnetic molecules alone. Both soluble and insoluble polysaccharide-linker-DTPA-Gd(3) complexes were effectively cleared from the body (rats) after oral administration. After intravenous administration, the biodistribution of dextran-linker-DTPA-Gd(3) complexes differed significantly from that of GdDTPA. Reduction of the nitroxide by ascorbic acid was retarded in the polysaccharide derivatives, particularly in starch derivatized with both nitroxide and linker-DTPA-Cu(2). These agents showed contrast enhancement in the gastrointestinal tract of rabbits.

  15. Mobility of TOAC spin-labelled peptides binding to the Src SH3 domain studied by paramagnetic NMR

    Energy Technology Data Exchange (ETDEWEB)

    Lindfors, Hanna E. [Leiden University, Leiden Institute of Chemistry, Gorlaeus Laboratories (Netherlands); Koning, Peter E. de; Wouter Drijfhout, Jan [Leiden University Medical Centre, Department of Immunohematology and Blood Transfusion (Netherlands); Venezia, Brigida; Ubbink, Marcellus [Leiden University, Leiden Institute of Chemistry, Gorlaeus Laboratories (Netherlands)], E-mail: m.ubbink@chem.leidenuniv.nl

    2008-07-15

    Paramagnetic relaxation enhancement provides a tool for studying the dynamics as well as the structure of macromolecular complexes. The application of side-chain coupled spin-labels is limited by the mobility of the free radical. The cyclic, rigid amino acid spin-label TOAC (2,2,6,6-Tetramethylpiperidine-1-oxyl-4-amino-4-carboxylic acid), which can be incorporated straightforwardly by peptide synthesis, provides an attractive alternative. In this study, TOAC was incorporated into a peptide derived from focal adhesion kinase (FAK), and the interaction of the peptide with the Src homology 3 (SH3) domain of Src kinase was studied, using paramagnetic NMR. Placing TOAC within the binding motif of the peptide has a considerable effect on the peptide-protein binding, lowering the affinity substantially. When the TOAC is positioned just outside the binding motif, the binding constant remains nearly unaffected. Although the SH3 domain binds weakly and transiently to proline-rich peptides from FAK, the interaction is not very dynamic and the relative position of the spin-label to the protein is well-defined. It is concluded that TOAC can be used to generate reliable paramagnetic NMR restraints.

  16. Correlation between the rate of bioreduction of nitroxide spin label by human tumor cells and their low-dose radiation response

    International Nuclear Information System (INIS)

    The authors discuss a correlation observed between the bioreduction of nitroxide spin label by four human tumor cell lines and a normal tissue fibroblast clone and their low-dose radiation response, specifically their DQ. In measurements of the bioreduction rate of several other cell lines, this correlation appears to persist. In order to define the mechanism of this correlation, they have begun by subtly altering the measurement conditions. The original conditions for measurement involved adding the spin label to cells whose culture medium had been changed (the label was added to the new medium). By delaying the addition of the label to the culture medium, they substantially reduced the variation of the bioreduction rate between the cell lines. This implies that the fresh medium provides a nonspecific irritant or disequilibrium to the cultured cell system to which they response variably by accelerating, among other things, the metabolic process responsible for spin label bioreduction

  17. Solvent effect on librational dynamics of spin-labelled haemoglobin by ED- and CW-EPR.

    Science.gov (United States)

    Scarpelli, Francesco; Bartucci, Rosa; Sportelli, Luigi; Guzzi, Rita

    2011-03-01

    Two-pulse, echo-detected electron paramagnetic resonance (ED-EPR) spectra and continuous-wave EPR (CW-EPR) spectra were used to investigate the solvent effect on the librational motion of human haemoglobin spin-labelled on cysteine β93 with the nitroxide derivative of maleimide, 6-MSL. Protein samples fully hydrated in phosphate buffer solution (PBS), in a 60% v/v glycerol/water mixture and in the lyophilized form were measured at cryogenic temperature in the frozen state. The protein librational motion was characterized by the amplitude-correlation time product, τ(c), deduced from the ED-EPR spectra. The librational amplitude, τ(c), was determined independently, from the motionally averaged hyperfine splitting in the CW-EPR spectra, and the librational correlation time, τ(c), was derived from the combination of the pulsed and conventional EPR data. Rapid librational motion of small amplitude was detected in all samples. In each case, the librational dynamics was restricted up to 180 K, beyond which it increased steeply for the hydrated protein in PBS and in the presence of glycerol. In contrast, in the dehydrated protein, the librational dynamics was hindered and less dependent on temperature up to ~240 K. In all samples, deviated from small values only for T > 200 K, where a rapid increase of was evident for the hydrated samples, whereas limited temperature variation was shown in the lyophilized samples. The librational correlation time was in the sub-nanosecond regime and weakly dependent on temperature. The results evidence that solvent favours protein dynamics.

  18. Deep arterial injury during experimental angioplasty: relation to a positive indium-111-labeled platelet scintigram, quantitative platelet deposition and mural thrombosis

    International Nuclear Information System (INIS)

    Although it is not clear why coronary occlusion and restenosis occur after successful coronary angioplasty, factors related to the procedure may influence early and late results. The possible adverse effects of a medial tear documented histologically and produced during balloon angioplasty of the common carotid arteries were studied in 30 fully heparinized (100 U/kg body weight) normal pigs. Scanning electron microscopy showed endothelial denudation and extensive platelet deposition in all dilated arterial segments. Visible macroscopic mural thrombus was present within an hour of the procedure in 29 (91%) of the 32 arteries that had a medial tear documented by histologic study; the tear produced an indium-111-labeled platelet deposition of 116.4 +/- 26.5 X 10(6)/cm2 (mean +/- SE) and total thrombotic occlusion in 2 arteries (4%). None of the 24 arteries without a medial tear had a thrombus, and the mean platelet deposition in that group was 7.0 +/- 0.5 X 10(6)/cm2 (p less than 0.0008). In 12 pigs scanned with a gamma camera, visible thrombus was associated with platelet deposition in excess of 20 X 10(6)/cm2 in 12 arteries, 9 of which had a positive indium-111-labeled platelet scintigram. Thus, arterial angioplasty causes deep arterial injury, which appears to be a major cause of mural thrombosis, heavy platelet deposition, a positive indium-111-labeled platelet scintigram and acute arterial occlusion. A positive indium-111-labeled platelet scintigram was always associated with macroscopic thrombus of at least 20 > 10(6) platelets/cm2 and underlying deep arterial injury

  19. Design, Synthesis, EPR-Studies and Conformational Bias of Novel Spin-Labeled DCC-Analogues for the Highly Regioselective Labeling of Aliphatic and Aromatic Carboxylic Acids.

    Science.gov (United States)

    Gölz, Jan Philipp; NejatyJahromy, Yaser; Bauer, Mirko; Muhammad, Ashraf; Schnakenburg, Gregor; Grimme, Stefan; Schiemann, Olav; Menche, Dirk

    2016-07-01

    Novel types of spin-labeled N,N'-dicyclohexylcarbodiimides (DCC) are reported that bear a 2,2,6,6-tetramethylpiperidinyloxyl (TEMPO) residue on one side and different aromatic and aliphatic cyclohexyl analogues on the other side of the diimide core. These readily available novel reagents add efficiently to aliphatic and aromatic carboxylic acids, forming two possible spin-labeled amide derivatives with different radical distances of the resulting amide. The addition of aromatic DCC analogues proceeds with excellent selectivity, giving amides where the carboxylic acid is exclusively connected to the aromatic residue, while little or no selectivity was observed for the aliphatic congeners. The usefulness of these adducts in structural studies was demonstrated by EPR (electron paramagnetic resonance) measurements of biradical adducts of biphenyl-4,4'-dicarboxylic acids. These analyses also reveal high degrees of conformational bias for aromatic DCC derivatives, which further underlines the powerfulness of these novel reagents. This observation was further corroborated by quantum chemical calculations, giving a detailed understanding of the structural dynamics, while detailed information on the solid state structure of all novel reagents was obtained by X-ray structure analyses. PMID:27272435

  20. Contrast optimization in multiphase arterial spin labeling; Otimizacao do contraste em ASL multi-fase

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Fernando F.; Paschoal, Andre M., E-mail: paiva@ifsc.usp.br [Universidade de Sao Paulo (CIERMag/USP), Sao Carlos, SP (Brazil). Instituto de Fisica; Foerster, Bernd U. [Philips Medical Systems LatAm, Sao Paulo, SP (Brazil); Tovar-Moll, Fernanda; Moll, Jorge [Instituto D' Or de Pesquisa e Ensino, Rio de Janeiro, RJ (Brazil)

    2013-08-15

    Multiphase ASL is an effective way to overcome the regional variation of the transit time that difficult the estimation of perfusion values. However, with conventional multiple phases ASL techniques, the ASL contrast at later phases is impaired due to repeated application of excitation pulses and longitudinal relaxation making it difficult to evaluate the tissue perfusion in regions where the transit time is longer. In the present study, we show an improvement of the acquisition scheme by exploring a modulation on the flip angle of the MR acquisition to keep the ASL contrast constant over multiple phases. (author)

  1. RELATIONSHIP BETWEEN EFFICENCIES OF SEGMENTAL HEPATIC ARTERY CHEMOEMBOLIZATION AND PCNA LABELING INDEX IN HCC

    Institute of Scientific and Technical Information of China (English)

    李玉亮; 邵广瑞

    2004-01-01

    Objective: To evaluate the relationship between the efficiencies of subsegmental TAE and the expression of PCNA with ABC immunohistochemical staining in HCCs. Methods: Ultrasound-guided needle biopsies were performed in 43 patients (41 men, 2 women; age range: 32~75 years, mean, 55.6 years). PCNA were examined using ABC immunohistochemical staining. Tumor scores of PCNA were assessed by counting the positive nuclei per 1,000 cells. All the cases received subsegmental TAE with iodized oil and gelatin sponge. A correlation between the expression of PCNA and the efficiencies of subsegmental TAE was sought. Normality test, rank sum test and Chi-square test were used in statistical analyses with SAS package. Results: The mean PCNA labeling index was 58±29(range, 27-100%) in 43 patients. When compared with the macroscopic and pathologic parameters, PCNA labeling index was found to be significantly related to the presence and activity of cirrhosis. PCNA labeling index did not related to patients' age, sex, HbsAg status or serum α-fetoprotein level. The PCNA labeling index corresponded to the degree of histological differentiation (Edmenderson- Steiner grading). The survival rates after subsegmental TAE were respectively 86.05%, 65.12% and 51.16% in one-, two- and three-years, and were significantly higher in the low labeling index group than that in the high labeling index group. Conclusion: The PCNA labeling index was shown to be closely related to histological characteristics and survival of the patients.

  2. Interaction of bee venom melittin with zwitterionic and negatively charged phospholipid bilayers : a spin-label electron spin resonance study

    OpenAIRE

    Kleinschmidt, Jörg H.; Mahaney, James E.; Thomas, David D.; Marsh, Derek

    1997-01-01

    Electron spin resonance (ESR) spectroscopy was used to study the penetration and interaction of bee venom melittin with dimyristoylphosphatidylcholine (DMPC) and ditetradecylphosphatidylglycerol (DTPG) bilayer membranes. Melittin is a surface-active, amphipathic peptide and serves as a useful model for a variety of membrane interactions, including those of presequences and signal peptides, as well as the charged subdomain of the cardiac regulatory protein phospholamban. Derivatives of phospha...

  3. Conformational distributions and hydrogen bonding in gel and frozen lipid bilayers: a high frequency spin-label ESR study.

    Science.gov (United States)

    Dzikovski, Boris; Tipikin, Dmitriy; Freed, Jack

    2012-06-14

    The ESR parameters of PC spin labels in frozen membranes do not simply represent the membrane polarity or water penetration profile. Instead, they show a distribution between hydrogen-bonded (HB) and non-hydrogen-bonded (non-HB) states, which is affected by a number of factors in the membrane composition. Similar to the exclusion of solutes from crystallizing solvents, the pure bulk gel phase excludes nitroxides, forcing acyl chains to take bent conformations. In these conformations, the nitroxide is hydrogen-bonded. Furthermore, upon gradual cooling in the supercooled gel, PC labels undergo slow lateral aggregation, resulting in a broad background signal. However, if the sample is instantly frozen, this background is replaced by the HB component. In membranes with cholesterol, the observed HB/non-HB ratio can best be described by a partition-like equilibrium between nitroxides located in defects of lipid structure within the hydrophobic core and those close to the membrane surface. PMID:22324811

  4. Intramembrane Water Associated with TOAC Spin-Labeled Alamethicin: Electron Spin-Echo Envelope Modulation by D2O

    Science.gov (United States)

    Bartucci, R.; Guzzi, R.; Sportelli, L.; Marsh, D.

    2009-01-01

    Alamethicin is a 20-residue, hydrophobic, helical peptide, which forms voltage-sensitive ion channels in lipid membranes. The helicogenic, nitroxyl amino acid TOAC was substituted isosterically for Aib at residue positions 1, 8, or 16 in a F50/5 alamethicin analog to enable EPR studies. Electron spin-echo envelope modulation (ESEEM) spectroscopy was used to investigate the water exposure of TOAC-alamethicin introduced into membranes of saturated or unsaturated diacyl phosphatidylcholines that were dispersed in D2O. Echo-detected EPR spectra were used to assess the degree of assembly of the peptide in the membrane, via the instantaneous diffusion from intermolecular spin-spin interactions. The profile of residue exposure to water differs between membranes of saturated and unsaturated lipids. In monounsaturated dioleoyl phosphatidylcholine, D2O-ESEEM intensities decrease from TOAC1 to TOAC8 and TOAC16 but not uniformly. This is consistent with a transmembrane orientation for the protoassembled state, in which TOAC16 is located in the bilayer leaflet opposite to that of TOAC1 and TOAC8. Relative to the monomer in fluid bilayers, assembled alamethicin is disposed asymmetrically about the bilayer midplane. In saturated dimyristoyl phosphatidylcholine, the D2O-ESEEM intensity is greatest for TOAC8, indicating a more superficial location for alamethicin, which correlates with the difference in orientation between gel- and fluid-phase membranes found by conventional EPR of TOAC-alamethicin in aligned phosphatidylcholine bilayers. Increasing alamethicin/lipid ratio in saturated phosphatidylcholine shifts the profile of water exposure toward that with unsaturated lipid, consistent with proposals of a critical concentration for switching between the two different membrane-associated states. PMID:19186137

  5. Distance Measurements on Orthogonally Spin-Labeled Membrane Spanning WALP23 Polypeptides

    NARCIS (Netherlands)

    Lueders, P.; Jäger, H.; Hemminga, M.A.; Jeschke, G.; Yulikov, M.

    2013-01-01

    EPR-based Gd(III)-nitroxide distance measurements were performed on a series of membrane-incorporated orthogonally labeled WALP23 polypeptides. The obtained distance distributions were stable upon the change of detection frequency from 10 GHz (X-band) to 35 GHz (Q-band). The alpha-helical pitch of W

  6. High-speed label-free detection by spinning-disk micro-interferometry

    OpenAIRE

    Varma, M. M.; Inerowicz, H. D.; Regnier, F. E.; Nolte, D. D.

    2004-01-01

    Spinning-disk interferometers are a new class of analytic sensors to detect immobilized biomolecules with high speed and high sensitivity. The disks are composed of a large number of surface-normal self-referencing interferometers, analogous to an optical CD, but operating on the principle of microdiffraction quadrature that achieves sensitive linear detection of bound molecules. The surface-normal structures have a small footprint of only 20 mum each, allowing potential integration to over a...

  7. Imaging of injured and atherosclerotic arteries in mice using fluorescence-labeled glycoprotein VI-Fc

    Energy Technology Data Exchange (ETDEWEB)

    Bigalke, Boris, E-mail: boris.bigalke@med.uni-tuebingen.de [Medizinische Klinik III, Kardiologie und Kreislauferkrankungen, Eberhard-Karls-Universitaet Tuebingen (Germany); Division of Imaging Sciences, St Thomas' Hospital, King' s College London (United Kingdom); Pohlmeyer, Ilka; Schoenberger, Tanja [Medizinische Klinik III, Kardiologie und Kreislauferkrankungen, Eberhard-Karls-Universitaet Tuebingen (Germany); Griessinger, Christoph M. [Labor fuer Praeklinische Bildgebung und Bildgebungstechnologie der Werner-Siemens-Stiftung, Radiologische Klinik, Eberhard-Karls-Universitaet Tuebingen (Germany); Ungerer, Martin [Corimmun GmbH, Martinsried (Germany); Botnar, Rene M. [Division of Imaging Sciences, St Thomas' Hospital, King' s College London (United Kingdom); Pichler, Bernd J. [Labor fuer Praeklinische Bildgebung und Bildgebungstechnologie der Werner-Siemens-Stiftung, Radiologische Klinik, Eberhard-Karls-Universitaet Tuebingen (Germany); Gawaz, Meinrad [Medizinische Klinik III, Kardiologie und Kreislauferkrankungen, Eberhard-Karls-Universitaet Tuebingen (Germany)

    2011-08-15

    Purpose: To assess endothelial injury and repair using fluorescence-labeled glycoprotein VI (GPVI)-Fc in a murine model. Materials and methods: Three 4-week-old male ApoE-deficient (ApoE{sup -/-})-mice were fed with a 1.25% cholesterol diet over 16 weeks and compared to three wild type (WT) C57BL/6J-mice in a wire-induced vascular injury model. Another group of WT mice (n = 10) were mechanically injured by carotid ligation. Fluorescence-labeled GPVI-Fc (150 {mu}g/mouse) was administered and assessed by optical imaging 24 h after injury and compared to another group (n = 3) which was injected two days after injury and sacrificed another day later. Results: After denudation, all injured carotids of WT mice showed a higher mean fluorescence signal than the corresponding intact carotids of the same animals (48.4 {+-} 18.9 vs. 10.4 {+-} 1.0; P = 0.028). Injection of unlabeled GPVI-Fc 20 h and 3 h before injecting GPVI-Fc-FITC significantly reduced the fluorescence signal in injured carotids to 14.6 {+-} 4.6, while intact carotids showed a signal of 9.2 {+-} 1.1; P = 0.046. Ligation injury resulted with an increased GPVI-Fc-binding to injured carotids compared to intact carotids (31.53 {+-} 6.18 vs. 16.48 {+-} 5.15; P = 0.039). Three days after injury and 24 h after GPVI-Fc-FITC injection, differences between intact and injured carotids have vanished (12.51 {+-} 2.76 vs. 14.76 {+-} 1.59; P = 0.519). Conclusions: A GPVI-based plaque imaging system could help to identify vascular lesions and to take a precautionary measure as necessary.

  8. Relaxation-based distance measurements between a nitroxide and a lanthanide spin label

    Science.gov (United States)

    Jäger, H.; Koch, A.; Maus, V.; Spiess, H. W.; Jeschke, G.

    2008-10-01

    Distance measurements by electron paramagnetic resonance techniques between labels attached to biomacromolecules provide structural information on systems that cannot be crystallized or are too large to be characterized by NMR methods. However, existing techniques are limited in their distance range and sensitivity. It is anticipated by theoretical considerations that these limits could be extended by measuring the enhancement of longitudinal relaxation of a nitroxide label due to a lanthanide complex label at cryogenic temperatures. The relaxivity of the dysprosium complex with the macrocyclic ligand DOTA can be determined without direct measurements of longitudinal relaxation rates of the lanthanide and without recourse to model compounds with well defined distance by analyzing the dependence of relaxation enhancement on either temperature or concentration in homogeneous glassy frozen solutions. Relaxivities determined by the two calibration techniques are in satisfying agreement with each other. Error sources for both techniques are examined. A distance of about 2.7 nm is measured in a model compound of the type nitroxide-spacer-lanthanide complex and is found in good agreement with the distance in a modeled structure. Theoretical considerations suggest that an increase of the upper distance limit requires measurements at lower fields and temperatures.

  9. Structural characteristics of the hydrophobic patch of azurin and its interaction with p53: a site-directed spin labeling study

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Site-directed spin labeling (SDSL) is a powerful tool for monitoring protein structure, dynamics and conformational changes. In this study, the domain-specific properties of azurin and its interaction with p53 were studied using this technique. Mutations of six residues, that are located in the hydrophobic patch of azurin, were prepared and spin labeled. Spectra of the six azurin mutants in solution showed that spin labeled residues 45 and 63 are in a very restricted environment, residues 59 and 65 are in a spacious environment and have free movement, and residues 49 and 51 are located in a relatively closed pocket. Polarity experiments confirmed these results. The changes observed in the spectra of spin labeled azurin upon interaction with p53 indicate that the hydrophobic patch is involved in this interaction. Our results provide valuable insight into the topographic structure of the hydrophobic domain of azurin, as well as direct evidence of its interaction with p53 in solution via the hydrophobic patch. Cytotoxicity studies of azurin mutants showed that residues along the hydrophobic patch are important for its cytotoxicity.

  10. Do "good" food products make others look "bad"? Spin-off effects of labels for sustainable food production in the consumer perception

    NARCIS (Netherlands)

    Binnekamp, M.H.A.; Ingenbleek, P.T.M.

    2008-01-01

    Abstract Purpose ¿ The objective of this study is to examine whether sustainability labels like Fair Trade have a spin-off effect to mainstream products in the consumer perception: do consumers perceive mainstream products and brands more negatively in the presence of a product with a sustainability

  11. The free radical spin-trap alpha-PBN attenuates periinfarct depolarizations following permanent middle cerebral artery occlusion in rats without reducing infarct volume

    DEFF Research Database (Denmark)

    Christensen, Thomas; Bruhn, Torben; Diemer, Nils Henrik

    2003-01-01

    The effect of the free radical spin-trap alpha-phenyl-butyl-tert-nitrone (alpha-PBN) in permanent focal cerebral ischemia in rats was examined in two series of experiments. In the first, rats were subjected to permanent occlusion of the middle cerebral artery (MCAO) and treated 1 h after occlusion...

  12. Local motion and conformational changes in the cuticle of Clivia miniata Regel : A microfluorescence and spin-label study.

    Science.gov (United States)

    Wunderlich, A P; Gaub, H; Marsh, D; Sackmann, E

    1990-07-01

    The temperature dependence of the local diffusion of fluorescent molecular probes of various polarities (alkane, long-chain fatty acid, short-chain alcohol and fatty acid), all labelled with 7-nitrobenz-2-oxa-1,3-diazol-4-yl in the cuticle of Clivia miniata Regel was studied by the technique of fluorescence recovery after photobleaching. The technique yields the coefficient of diffusion, D, in the plane of the cuticle over distances of some 10 μm and the fraction, R, of mobile reporter molecules. The inner (more hydrophilic) and the outer (more hydrophobic) faces of the cuticle were studied separately by appropriate incubation. The value of D was found to depend sensitively on the polarity of the probe, the temperature and the position within the cuticle (outer hydrophobic or inner hydrophilic side). Depending on the type of probe, D increased (in the case of the alkane) or decreased (in the case of the alcohol) after removal of the (monomeric) waxes. The electron-spin-resonance (ESR) spectra of incorporated spin-labelled fatty-acid probes measured in the intact cuticle contained a major component similar to the spectrum recorded from the polymerized matrix from which waxes had been extracted, and a second component similar to the spectrum from the monomeric waxes. At low temperatures, the ESR spectra from labels at two different chain positions corresponded to chain motion which was slow on the ESR timescale. At high temperatures, the spectral component from the monomeric waxes indicated chain motions in the motional narrowing regime which were of an essentially isotropic nature.No evidence was found for a liquid-crystalline lipid phase such as found for the polar lipids in cell membranes, nor was there evidence for a sharp, thermotropic, lipid-phase transition either in the cuticle or in the waxes. Experiments with oriented samples did not demonstrate the presence of large domains with a uniform orientation of the lipid chains relative to the cuticular layers

  13. Structural Changes of a Doubly Spin-Labeled Chemically Driven Molecular Shuttle Probed by PELDOR Spectroscopy.

    Science.gov (United States)

    Franchi, Paola; Bleve, Valentina; Mezzina, Elisabetta; Schäfer, Christian; Ragazzon, Giulio; Albertini, Marco; Carbonera, Donatella; Credi, Alberto; Di Valentin, Marilena; Lucarini, Marco

    2016-06-20

    Gaining detailed information on the structural rearrangements associated with stimuli-induced molecular movements is of utmost importance for understanding the operation of molecular machines. Pulsed electron-electron double resonance (PELDOR) was employed to monitor the geometrical changes arising upon chemical switching of a [2]rotaxane that behaves as an acid-base-controlled molecular shuttle. To this aim, the rotaxane was endowed with stable nitroxide radical units in both the ring and axle components. The combination of PELDOR data and molecular dynamic calculations indicates that in the investigated rotaxane, the ring displacement along the axle, caused by the addition of a base, does not alter significantly the distance between the nitroxide labels, but it is accompanied by a profound change in the geometry adopted by the macrocycle. PMID:27123774

  14. The effects of general anesthetics on ESR spectra of spin labels in phosphatidylcholine vesicles containing purified Na,K-ATPase or microsomal protein

    Energy Technology Data Exchange (ETDEWEB)

    Shibuya, Makiko, E-mail: shibu@den.hokudai.ac.jp [Department of Dental Anesthesiology, Graduate School of Dental Medicine, Hokkaido University (Japan); Hiraoki, Toshifumi [Division of Applied Physics, Graduate School of Engineering, Hokkaido University (Japan); Kimura, Kunie; Fukushima, Kazuaki [Department of Dental Anesthesiology, Graduate School of Dental Medicine, Hokkaido University (Japan); Suzuki, Kuniaki [Department of Molecular Cell Pharmacology, Graduate School of Dental Medicine, Hokkaido University (Japan)

    2012-12-01

    Highlights: Black-Right-Pointing-Pointer We studied the effects of general anesthetics on liposome using ESR spectra. Black-Right-Pointing-Pointer Two spin labels, 5-DSA and 16-DSA, were located in different position in liposome. Black-Right-Pointing-Pointer Anesthetics did not change the environment around the spin labels in the liposome. Black-Right-Pointing-Pointer Anesthetics remained on the surface of the lipid bilayer of liposome. Black-Right-Pointing-Pointer Proteins in the liposome did not change the effects of anesthetics on liposome. - Abstract: We investigated the effects of general anesthetics on liposome containing spin labels, 5-doxyl stearic acid (5-DSA) and 16-doxyl stearic acid (16-DSA), and purified Na,K-ATPase or membrane protein of microsome using an electron spin resonance (ESR) spectroscopy. The spectra of 16-DSA in liposomes with both proteins showed three sharp signals compared with 5-DSA. The difference in the order parameter S value of 5-DSA and 16-DSA suggested that the nitroxide radical location of 5-DSA and 16-DSA were different in the membrane bilayer. The results were almost the same as those obtained in liposomes without proteins. The addition of sevoflurane, isoflurane, halothane, ether, ethanol and propofol increased the intensity of the signals, but the clinical concentrations of anesthetics did not significantly alter the S and {tau} values, which are indices of the fluidity of the membrane. These results suggest that anesthetics remain on the surface of the lipid bilayer and do not act on both the inside hydrophobic area and the relatively hydrophilic area near the surface. These results and others also suggest that the existence of Na,K-ATPase and microsomal proteins did not affect the environment around the spin labels in the liposome and the effects of anesthetics on liposome as a model membrane.

  15. Kinetics of rapid covalent bond formation of aniline with humic acid: ESR investigations with nitroxide spin labels

    Science.gov (United States)

    Glinka, Kevin; Matthies, Michael; Theiling, Marius; Hideg, Kalman; Steinhoff, Heinz-Jürgen

    2016-04-01

    Sulfonamide antibiotics used in livestock farming are distributed to farmland by application of slurry as fertilizer. Previous work suggests rapid covalent binding of the aniline moiety to humic acids found in soil. In the current work, kinetics of this binding were measured in X-band EPR spectroscopy by incubating Leonardite humic acid (LHA) with a paramagnetic aniline spin label (anilino-NO (2,5,5-Trimethyl-2-(3-aminophenyl)pyrrolidin-1-oxyl)). Binding was detected by a pronounced broadening of the spectral lines after incubation of LHA with anilino-NO. The time evolution of the amplitude of this feature was used for determining the reaction kinetics. Single- and double-exponential models were fitted to the data obtained for modelling one or two first-order reactions. Reaction rates of 0.16 min-1 and 0.012 min-1, were found respectively. Addition of laccase peroxidase did not change the kinetics but significantly enhanced the reacting fraction of anilino-NO. This EPR-based method provides a technically simple and effective method for following rapid binding processes of a xenobiotic substance to humic acids.

  16. Protective spin-labeled fluorenes maintain amyloid beta peptide in small oligomers and limit transitions in secondary structure

    Energy Technology Data Exchange (ETDEWEB)

    Altman, Robin [Univ. of California, Davis, CA (United States). Dept. of Biochemistry and Molecular Medicine; Ly, Sonny [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Physical and Life Science Directorate; Hilt, Silvia [Univ. of California, Davis, CA (United States). Dept. of Biochemistry and Molecular Medicine; Petrlova, Jitka [Univ. of California, Davis, CA (United States). Dept. of Biochemistry and Molecular Medicine; Maezawa, Izumi [Univ. of California Davis, Sacramento, CA (United States). MIND Inst. and Dept. of Pathology and Laboratory Medicine; Kálai, Tamás [Univ. of Pecs (Hungary). Inst. of Organic and Medicinal Chemistry; Hideg, Kálmán [Univ. of Pecs (Hungary). Inst. of Organic and Medicinal Chemistry; Jin, Lee-Way [Univ. of California Davis, Sacramento, CA (United States). MIND Inst. and Dept. of Pathology and Laboratory Medicine; Laurence, Ted A. [Univ. of California, Davis, CA (United States). Dept. of Biochemistry and Molecular Medicine; Voss, John C. [Univ. of California, Davis, CA (United States). Dept. of Biochemistry and Molecular Medicine

    2015-12-01

    Alzheimer’s disease is characterized by the presence of extracellular plaques comprised of amyloid beta (Aβ) peptides. Soluble oligomers of the Aβ peptide underlie a cascade of neuronal loss and dysfunction associated with Alzheimer's disease. Single particle analyses of Aβ oligomers in solution by fluorescence correlation spectroscopy (FCS) were used to provide real-time descriptions of how spin-labeled fluorenes (SLFs; bi-functional small molecules that block the toxicity of Aβ) prevent and disrupt oligomeric assemblies of Aβ in solution. The FCS results, combined with electron paramagnetic resonance spectroscopy and circular dichroism spectroscopy, demonstrate SLFs can inhibit the growth of Aβ oligomers and disrupt existing oligomers while retaining Aβ in a largely disordered state. Furthermore, while the ability of SLF to block Aβ toxicity correlates with a reduction in oligomer size, our results suggest the conformation of Aβ within the oligomer determines the toxicity of the species. Attenuation of Aβ toxicity, which has been associated primarily with the soluble oligomeric form, can be achieved through redistribution of the peptides into smaller oligomers and arrest of the fractional increase in beta secondary structure.

  17. QM/MD studies of the dynamics of the MTSL spin label in Aurora-A kinase protein activation loop

    CERN Document Server

    Concilio, Maria Grazia; Bayliss, Richard; Burgess, Selena

    2015-01-01

    Molecular dynamics(MD)simulations using a graphics processing unit (GPU) has been employed in order to determine the conformational space of the methane-thiosulfonate spin label (MTSL) attached to the activation loop of the Aurora-A kinase protein and compared with quantum mechanical (QM) methods rooted on density functional theory (DFT). MD provided a wealth of information about interactions between the MTSL and the residues of the protein and on the different motional contributions to the overall dynamics of the MTSL. Data obtained from MD were seen to be in good agreement with those obtained from QM but the dynamics of the system revealed more interactions than those observed from QM methods. A strong correlation between the tumbling of the protein and the transitions of the X4 and X5 dihedral angles of the MTSL, was observed with a consequent effect also the distribution of the nitroxide(NO)group in the space. Theoretical EPR spectra calculated from opportunely selected MD frames showing interactions betw...

  18. Electron paramagnetic resonance (EPR) study of spin-labeled camptothecin derivatives: a different look of the ternary complex.

    Science.gov (United States)

    Ricci, Antonio; Marinello, Jessica; Bortolus, Marco; Sánchez, Albert; Grandas, Anna; Pedroso, Enrique; Pommier, Yves; Capranico, Giovanni; Maniero, Anna Lisa; Zagotto, Giuseppe

    2011-02-24

    Camptothecin (CPT) derivatives are clinically effective poisons of DNA topoisomerase I (Top1) able to form a ternary complex with the Top1-DNA complex. The aim of this investigation was to examine the dynamic aspects of the ternary complex formation by means of site-directed spin labeling electron paramagnetic resonance (SDSL-EPR). Two semisynthetic CPT derivatives bearing the paramagnetic moiety were synthesized, and their biological activity was tested. A 22-mer DNA oligonucleotide sequence with high affinity cleavage site for Top1 was also synthesized. EPR experiments were carried out on modified CPT in the presence of DNA, of Top1, or of both. In the last case, a slow motion component in the EPR signal appeared, indicating the formation of the ternary complex. Deconvolution of the EPR spectrum allowed to obtain the relative drug amounts in the complex. It was also possible to demonstrate that the residence time of CPT "trapped" in the ternary complex is longer than hundreds of microseconds. PMID:21254781

  19. Mapping molecular flexibility of spin labeled proteins on the nanosecond and longer time scales via CW lineshape analysis and osmolyte-perturbation EPR

    OpenAIRE

    López, Carlos Javier

    2012-01-01

    Proteins in solution exhibit structural fluctuations on a wide range of characteristic time scales, from fast backbone motions in the picosecond to nanosecond range to slow conformational exchange in the microsecond to millisecond time domain. These motions can play important roles in function, thus elucidation of molecular mechanisms underlying function requires experimental techniques capable of measuring motions on these time scales. Site directed spin labeling and EPR spectroscopy (SDSL-...

  20. Study on dipole-dipole interaction in spin labelled hemoglobin molecule by means of ESR spectroscopy; Badanie oddzialywan dipol-dipolowych w znakowanej spinowo czasteczce hemoglobiny metoda impulsowej spektroskopii EPR

    Energy Technology Data Exchange (ETDEWEB)

    Kostrzewa, A.; Froncisz, W. [Inst. Biologii Molekularnej, Uniwersytet Jagiellonski, Cracow (Poland)

    1994-12-31

    Dipole-dipole interactions in spin labelled hemoglobin molecule have been investigated by means of ESR. The spectral differences at 77 K between oxy-hemoglobin and ferry hemoglobin have been discussed. 4 refs, 3 figs, 1 tab.

  1. Morpholino spin-labeling for base-pair sequencing of a 3'-terminal RNA stem by proton homonuclear Overhauser enhancements: yeast ribosomal 5S RNA

    International Nuclear Information System (INIS)

    Base-pair sequences for 5S and 5.8S RNAs are not readily extracted from proton homonuclear nuclear Overhauser enhancement (NOE) connectivity experiments alone, due to extensive peak overlap in the downfield (11-15 ppm) proton NMR spectrum. In this paper, we introduce a new method for base-pair proton peak assignment for ribosomal RNAs, based upon the distance-dependent broadening of the resonances of base-pair protons spatially proximal to a paramagnetic group. Introduction of a nitroxide spin-label covalently attached to the 3'-terminal ribose provides an unequivocal starting point for base-pair hydrogen-bond proton NMR assignment. Subsequent NOE connectivities then establish the base-pair sequence for the terminal stem of a 5S RNA. Periodate oxidation of yeast 5S RNA, followed by reaction with 4-amino-2,2,6,6-tetramethylpiperidinyl-1-oxy (TEMPO-NH2) and sodium borohydride reduction, produces yeast 5S RNA specifically labeled with a paramagnetic nitroxide group at the 3'-terminal ribose. Comparison of the 500-MHz 1H NMR spectra of native and 3'-terminal spin-labeled yeast 5S RNA serves to identify the terminal base pair (G1 . C120) and its adjacent base pair (G2 . U119) on the basis of their proximity to the 3'-terminal spin-label. From that starting point, we have then identified (G . C, A . U, or G . U) and sequenced eight of the nine base pairs in the terminal helix via primary and secondary NOE's

  2. Blood tracer kinetics in the arterial tree.

    Directory of Open Access Journals (Sweden)

    Elias Kellner

    Full Text Available Evaluation of blood supply of different organs relies on labeling blood with a suitable tracer. The tracer kinetics is linear: Tracer concentration at an observation site is a linear response to an input somewhere upstream the arterial flow. The corresponding impulse response functions are currently treated empirically without incorporating the relation to the vascular morphology of an organ. In this work we address this relation for the first time. We demonstrate that the form of the response function in the entire arterial tree is reduced to that of individual vessel segments under approximation of good blood mixing at vessel bifurcations. The resulting expression simplifies significantly when the geometric scaling of the vascular tree is taken into account. This suggests a new way to access the vascular morphology in vivo using experimentally determined response functions. However, it is an ill-posed inverse problem as demonstrated by an example using measured arterial spin labeling in large brain arteries. We further analyze transport in individual vessel segments and demonstrate that experimentally accessible tracer concentration in vessel segments depends on the measurement principle. Explicit expressions for the response functions are obtained for the major middle part of the arterial tree in which the blood flow in individual vessel segments can be treated as laminar. When applied to the analysis of regional cerebral blood flow measurements for which the necessary arterial input is evaluated in the carotid arteries, present theory predicts about 20% underestimation, which is in agreement with recent experimental data.

  3. Blood tracer kinetics in the arterial tree.

    Science.gov (United States)

    Kellner, Elias; Gall, Peter; Günther, Matthias; Reisert, Marco; Mader, Irina; Fleysher, Roman; Kiselev, Valerij G

    2014-01-01

    Evaluation of blood supply of different organs relies on labeling blood with a suitable tracer. The tracer kinetics is linear: Tracer concentration at an observation site is a linear response to an input somewhere upstream the arterial flow. The corresponding impulse response functions are currently treated empirically without incorporating the relation to the vascular morphology of an organ. In this work we address this relation for the first time. We demonstrate that the form of the response function in the entire arterial tree is reduced to that of individual vessel segments under approximation of good blood mixing at vessel bifurcations. The resulting expression simplifies significantly when the geometric scaling of the vascular tree is taken into account. This suggests a new way to access the vascular morphology in vivo using experimentally determined response functions. However, it is an ill-posed inverse problem as demonstrated by an example using measured arterial spin labeling in large brain arteries. We further analyze transport in individual vessel segments and demonstrate that experimentally accessible tracer concentration in vessel segments depends on the measurement principle. Explicit expressions for the response functions are obtained for the major middle part of the arterial tree in which the blood flow in individual vessel segments can be treated as laminar. When applied to the analysis of regional cerebral blood flow measurements for which the necessary arterial input is evaluated in the carotid arteries, present theory predicts about 20% underestimation, which is in agreement with recent experimental data.

  4. Membrane docking geometry of GRP1 PH domain bound to a target lipid bilayer: an EPR site-directed spin-labeling and relaxation study.

    Directory of Open Access Journals (Sweden)

    Huai-Chun Chen

    Full Text Available The second messenger lipid PIP(3 (phosphatidylinositol-3,4,5-trisphosphate is generated by the lipid kinase PI3K (phosphoinositide-3-kinase in the inner leaflet of the plasma membrane, where it regulates a broad array of cell processes by recruiting multiple signaling proteins containing PIP(3-specific pleckstrin homology (PH domains to the membrane surface. Despite the broad importance of PIP(3-specific PH domains, the membrane docking geometry of a PH domain bound to its target PIP(3 lipid on a bilayer surface has not yet been experimentally determined. The present study employs EPR site-directed spin labeling and relaxation methods to elucidate the membrane docking geometry of GRP1 PH domain bound to bilayer-embedded PIP(3. The model target bilayer contains the neutral background lipid PC and both essential targeting lipids: (i PIP(3 target lipid that provides specificity and affinity, and (ii PS facilitator lipid that enhances the PIP(3 on-rate via an electrostatic search mechanism. The EPR approach measures membrane depth parameters for 18 function-retaining spin labels coupled to the PH domain, and for calibration spin labels coupled to phospholipids. The resulting depth parameters, together with the known high resolution structure of the co-complex between GRP1 PH domain and the PIP(3 headgroup, provide sufficient constraints to define an optimized, self-consistent membrane docking geometry. In this optimized geometry the PH domain engulfs the PIP(3 headgroup with minimal bilayer penetration, yielding the shallowest membrane position yet described for a lipid binding domain. This binding interaction displaces the PIP(3 headgroup from its lowest energy position and orientation in the bilayer, but the headgroup remains within its energetically accessible depth and angular ranges. Finally, the optimized docking geometry explains previous biophysical findings including mutations observed to disrupt membrane binding, and the rapid lateral

  5. Study of a DNA Duplex by Nuclear Magnetic Resonance and Molecular Dynamics Simulations. Validation of Pulsed Dipolar Electron Paramagnetic Resonance Distance Measurements Using Triarylmethyl-Based Spin Labels.

    Science.gov (United States)

    Lomzov, Alexander A; Sviridov, Eugeniy A; Shernuykov, Andrey V; Shevelev, Georgiy Yu; Pyshnyi, Dmitrii V; Bagryanskaya, Elena G

    2016-06-16

    Pulse dipole-dipole electron paramagnetic resonance (EPR) spectroscopy (double electron-electron resonance [DEER] or pulse electron-electron double resonance [PELDOR] and double quantum coherence [DQC]) allows for measurement of distances in biomolecules and can be used at low temperatures in a frozen solution. Recently, the possibility of distance measurement in a nucleic acid at a physiological temperature using pulse EPR was demonstrated. In these experiments, triarylmethyl (TAM) radicals with long memory time of the electron spin served as a spin label. In addition, the duplex was immobilized on modified silica gel particles (Nucleosil DMA); this approach enables measurement of interspin distances close to 4.5 nm. Nevertheless, the possible influence of TAM on the structure of a biopolymer under study and validity of the data obtained by DQC are debated. In this paper, a combination of molecular dynamics (MD) and nuclear magnetic resonance (NMR) methods was used for verification of interspin distances measured by the X-band DQC method. NMR is widely used for structural analysis of biomolecules under natural conditions (room temperature and an aqueous solution). The ultraviolet (UV) melting method and thermal series (1)H NMR in the range 5-95 °C revealed the presence of only the DNA duplex in solution at oligonucleotide concentrations 1 μM to 1.1 mM at temperatures below 40 °C. The duplex structures and conformation flexibility of native and TAM-labeled DNA complexes obtained by MD simulation were the same as the structure obtained by NMR refinement. Thus, we showed that distance measurements at physiological temperatures by the X-band DQC method allow researchers to obtain valid structural information on an unperturbed DNA duplex using terminal TAM spin labels.

  6. Radiation dose estimates for the arterial injection of Tc-99m labeled HSA microspheres and macroaggregated particles

    International Nuclear Information System (INIS)

    Particles of human serum albumin, such as macroaggregated albumin or microspheres, have been injected intra-arterially for the following indications: to examine tumor perfusion prior to and during chemotherapy, to examine coronary artery perfusion, and in the diagnosis of peripheral vascular disease. The region of distribution of the particles is localized according to the artery selected for injection. The radiation dose is affected by the distribution of the radioactivity in time and space and the physical parameters of the radionuclide. In addition, the radiation dose estimate takes into account the mass and geometry of the perfused volume. In certain cases, there is a significant amount of shunting of the injected particles; the radiation dose conferred by the shunted particles is to the lung tissue. 25 references, 6 tables

  7. The effect of black tea and caffeine on regional cerebral blood flow measured with arterial spin labeling

    OpenAIRE

    Vidyasagar, Rishma; Greyling, Arno; Draijer, Richard; Corfield, Douglas R; Parkes, Laura M.

    2013-01-01

    Black tea consumption has been shown to improve peripheral vascular function. Its effect on brain vasculature is unknown, though tea contains small amounts of caffeine, a psychoactive substance known to influence cerebral blood flow (CBF). We investigated the effects on CBF due to the intake of tea components in 20 healthy men in a double-blinded, randomized, placebo-controlled study. On separate days, subjects received a single dose of 184 mg caffeine (equivalent to one strong espresso coffe...

  8. Assessment of Alzheimer's disease risk with structural and functional magnetic resonance imaging : an arterial spin labeling study

    OpenAIRE

    Bangen, Katherine J.

    2010-01-01

    BACKGROUND : There are several risk factors for the development of Alzheimer's disease (AD) including the apolipoprotein E (APOE) e4 allele, an important susceptibility gene for AD, and mild cognitive impairment (MCI). The literature to date generally indicates that nondemented older adults at risk for AD by virtue of their cognitive (i.e., MCI) and/or genetic (i.e., APOE) status demonstrate reduced medial temporal lobe (MTL) volumes and divergent brain response patterns during memory encodin...

  9. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier;

    2010-01-01

    metabolism. So far, ASL has been restricted mostly to specialist centers due to a generally low SNR of the method and potential issues with user-dependent analysis needed to obtain quantitative measurement of cerebral blood flow (CBF). Here, we evaluated a particular implementation of ASL (called...... total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing...

  10. An a contrario approach for the detection of patient-specific brain perfusion abnormalities with arterial spin labelling.

    Science.gov (United States)

    Maumet, Camille; Maurel, Pierre; Ferré, Jean-Christophe; Barillot, Christian

    2016-07-01

    In this paper, we introduce a new locally multivariate procedure to quantitatively extract voxel-wise patterns of abnormal perfusion in individual patients. This a contrario approach uses a multivariate metric from the computer vision community that is suitable to detect abnormalities even in the presence of closeby hypo- and hyper-perfusions. This method takes into account local information without applying Gaussian smoothing to the data. Furthermore, to improve on the standard a contrario approach, which assumes white noise, we introduce an updated a contrario approach that takes into account the spatial coherency of the noise in the probability estimation. Validation is undertaken on a dataset of 25 patients diagnosed with brain tumours and 61 healthy volunteers. We show how the a contrario approach outperforms the massively univariate general linear model usually employed for this type of analysis. PMID:27039702

  11. An a contrario approach for the detection of patient-specific brain perfusion abnormalities with arterial spin labelling

    OpenAIRE

    Maumet, Camille; Maurel, Pierre; Ferré, Jean-Christophe; Barillot, Christian

    2016-01-01

    International audience In this paper, we introduce a new locally multivariate procedure to quantitatively extract voxel-wise patterns of abnormal perfusion in individual patients. This a contrario approach uses a multivariate metric from the computer vision community that is suitable to detect abnormalities even in the presence of closeby hypo- and hyper-perfusions. This method takes into account local information without applying Gaussian smoothing to the data. Furthermore, to improve on ...

  12. Optimal Blood Suppression inversion time based on breathing rates and heart rates to improve renal artery visibility in spatial labeling with multiple inversion pulses: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Yi Gang; Li, Fang; Long, Xue Ying; Liu, Hui; Wang, Xiao Yi; Liu, Jin Kang; Li, Wen Zheng [Dept. of Radiology, Xiangya Hospital, Central South University, Changsha (China); Shen, Hao [GE Healthcare, Waukesha (United States)

    2016-02-15

    To determine whether an optimal blood suppression inversion time (BSP TI) can boost arterial visibility and whether the optimal BSP TI is related to breathing rate (BR) and heart rate (HR) for hypertension subjects in spatial labeling with multiple inversion pulses (SLEEK). This prospective study included 10 volunteers and 93 consecutive hypertension patients who had undergone SLEEK at 1.5T MRI system. Firstly, suitable BSP TIs for displaying clearly renal artery were determined in 10 volunteers. Secondly, non-contrast enhanced magnetic resonance angiography with the suitable BSP TIs were performed on those hypertension patients. Then, renal artery was evaluated and an optimal BSP TI to increase arterial visibility was determined for each patient. Patients' BRs and HRs were recorded and their relationships with the optimal BSP TI were analyzed. The optimal BSP TI was negatively correlated with BR (r1 = -0.536, P1 < 0.001; and r2 = -0.535, P2 < 0.001) and HR (r1 = -0.432, P1 = 0.001; and r2 = -0.419, P2 = 0.001) for 2 readers (κ = 0.93). For improving renal arterial visibility, BSP TI = 800 ms could be applied as the optimal BSP TI when the 95% confidence interval were 17-19/min (BR1) and 74-82 bpm (HR1) for reader#1 and 17-19/min (BR2) and 74-83 bpm (HR2) for reader#2; BSP TI = 1100 ms while 14-15/min (BR1, 2) and 71-76 bpm (HR1, 2) for both readers; and BSP TI = 1400 ms when 13-16/min (BR1) and 63-68 bpm (HR1) for reader#1 and 14-15/min (BR2) and 64-70 bpm (HR2) for reader#2. In SLEEK, BSP TI is affected by patients' BRs and HRs. Adopting the optimal BSP TI based on BR and HR can improve the renal arterial visibility and consequently the working efficiency.

  13. EPR Studies of V-ATPase with Spin-Labeled Inhibitors DCC and Archazolid: Interaction Dynamics with Proton Translocating Subunit c.

    Science.gov (United States)

    Gölz, Jan Philipp; Bockelmann, Svenja; Mayer, Kerstin; Steinhoff, Heinz-Jürgen; Wieczorek, Helmut; Huss, Markus; Klare, Johann P; Menche, Dirk

    2016-02-17

    Vacuolar-type H(+) -ATPases (V-ATPases) have gained recent attention as highly promising anticancer drug targets, and therefore detailed structural analyses and studies of inhibitor interactions are very important research objectives. Spin labeling of the V-ATPase holoenzyme from the tobacco hornworm Manduca sexta and V-ATPase in isolated yeast (Saccharomyces cerevisiae) vacuoles was accomplished by two novel methods involving the covalent binding of a (2,2,6,6-tetramethylpiperidin-1-yl)oxyl (TEMPO) derivative of N,N'-dicyclohexylcarbodiimide (DCC) to the essential glutamate residue in the active site and the noncovalent interaction of a radical analogue of the highly potent inhibitor archazolid, a natural product from myxobacteria. Both complexes were evaluated in detail by electron paramagnetic resonance (EPR) spectroscopic studies and double electron-electron resonance (DEER) measurements, revealing insight into the inhibitor binding mode, dynamics, and stoichiometry as well as into the structure of the central functional subunit c of these medicinally important hetero-multimeric proton-translocating proteins. This study also demonstrates the usefulness of natural product derived spin labels as tools in medicinal chemistry. PMID:26662886

  14. Identification of pH-sensitive regions in the mouse prion by the cysteine-scanning spin-labeling ESR technique

    International Nuclear Information System (INIS)

    We analyzed the pH-induced mobility changes in moPrPC α-helix and β-sheets by cysteine-scanning site-directed spin labeling (SDSL) with ESR. Nine amino acid residues of α-helix1 (H1, codon 143-151), four amino acid residues of β-sheet1 (S1, codon 127-130), and four amino acid residues of β-sheet2 (S2, codon 160-163) were substituted for by cysteine residues. These recombinant mouse PrPC (moPrPC) mutants were reacted with a methane thiosulfonate sulfhydryl-specific spin labeling reagent (MTSSL). The 1/δH of the central (14N hyperfine) component (MI = 0) in the ESR spectrum of spin-labeled moPrPC was measured as a mobility parameter of nitroxide residues (R1). The mobilities of E145R1 and Y149R1 at pH 7.4, which was identified as a tertiary contact site by a previous NMR study of moPrP, were lower than those of D143R1, R147R1, and R150R1 reported on the helix surface. Thus, the mobility in the H1 region in the neutral solution was observed with the periodicity associated with a helical structure. On the other hand, the values in the S2 region, known to be located in the buried side, were lower than those in the S1 region located in the surface side. These results indicated that the mobility parameter of the nitroxide label was well correlated with the 3D structure of moPrP. Furthermore, the present study clearly demonstrated three pH-sensitive sites in moPrP, i.e. (1) the N-terminal tertiary contact site of H1 (2) the C-terminal end of H1, and (3) the S2 region. In particular, among these pH-sensitive sites, the N-terminal tertiary contact region of H1 was found to be the most pH-sensitive one and was easily converted to a flexible structure by a slight decrease of pH in the solution. These data provided molecular evidence to explain the cellular mechanism for conversion from PrPC to PrPSc in acidic organelles such as the endosome

  15. Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Juan; Sun, Gang; Yu, Bling Bing; Li, Min; Li, Guo Ying; Peng, Zhao Hui; Zhang, Xu Ping [Dept. of Medical Imaging, Jinan Military General Hospital, Jinan (China); Lu, Yang [Dept. of Radiology, University of Illinois College of Medicine, Illinois (United States)

    2012-11-15

    To explore the usefulness of 320-slice CT angiography (CTA) for evaluating the course of the anterior ethmoidal artery (AEA) and its relationship with adjacent structures by using three-dimensional (3D) spin digital subtraction angiography (DSA) as standard reference. From December 2008 to December 2010, 32 patients with cerebrovascular disease, who underwent both cranial 3D spin DSA and 320-slice CTA within a 30 day period from each other, were retrospectively reviewed. AEA course in ethmoid was analyzed in DSA and CTA. In addition, adjacent bony landmarks (bony notch in medial orbital wall, anterior ethmoidal canal, and anterior ethmoidal sulcus) were evaluated with CTA using the MPR technique oriented along the axial, coronal and oblique coronal planes in all patients. The dose length product (DLP) for CTA and the dose-area product (DAP) for 3D spin DSA were recorded. Effective dose (ED) was calculated. The entire course of the AEA was seen in all 32 cases (100%) with 3D spine DSA and in 29 of 32 cases (90.1%) with 320-slice CTA, with no significant difference (p = 0.24). In three cases where AEA was not visualized on 320-slice CTA, two were due to the dominant posterior ethmoidal artery, while the remaining case was due to diminutive AEA. On MPR images of 320-slice CT, a bony notch in the orbital medial walls was detected in all cases (100%, 64 of 64); anterior ethmoidal canal was seen in 28 of 64 cases (43.8%), and the anterior ethmoidal sulcus was seen in 63 of 64 cases (98.4%). The mean effective dose in CTA was 0.6 {+-} 0.25 mSv, which was significantly lower than for 3D spin DSA (1.3 {+-} 0.01 mSv) (p < 0.001). 320-slice CTA has a similar detection rate for AEA to that of 3D spin DSA; however, it is noninvasive, and may be preferentially used for the evaluation of AEA and its adjacent bony variations and pathologic changes in preoperative patients with paranasal sinus diseases.

  16. Functional localization in the human brain: Gradient-echo, spin-echo, and arterial spin-labeling fMRI compared with neuronavigated TMS.

    NARCIS (Netherlands)

    Diekhoff, S.; Uludag, K.; Sparing, R.; Tittgemeyer, M.; von Cramon, D.Y.; Grefkes, C.

    2010-01-01

    A spatial mismatch of up to 14 mm between optimal transcranial magnetic stimulation (TMS) site and functional magnetic resonance imaging (fMRI) signal has consistently been reported for the primary motor cortex. The underlying cause might be the effect of magnetic susceptibility around large drainin

  17. Preparation, characterization and magnetic behavior of a spin-labelled physical hydrogel containing a chiral cyclic nitroxide radical unit fixed inside the gelator molecule.

    Science.gov (United States)

    Takemoto, Yusa; Yamamoto, Takayuki; Ikuma, Naohiko; Uchida, Yoshiaki; Suzuki, Katsuaki; Shimono, Satoshi; Takahashi, Hiroki; Sato, Nobuhiro; Oba, Yojiro; Inoue, Rintaro; Sugiyama, Masaaki; Tsue, Hirohito; Kato, Tatsuhisa; Yamauchi, Jun; Tamura, Rui

    2015-07-21

    An optically active amphiphilic nitroxide radical compound [(S,S,R)-], which contains a paramagnetic (2S,5S)-2,5-dimethyl-2,5-diphenylpyrrolidine-N-oxyl radical group fixed in the inner position together with a hydrophobic long alkyl chain and a hydrophilic (R)-alanine residue in the opposite terminal positions, was found to serve as a low-molecular-weight gelator in H2O to give rise to a spin-labelled physical hydrogel. Characterization of the hydrogel was performed by microscopic (SEM, TEM and AFM) techniques, XRD and SAXS measurements, and IR, UV and CD spectroscopies. The gel-sol transition temperature was determined by EPR spectral line-width (ΔHpp) analysis. Measurement of the temperature dependence of relative paramagnetic susceptibility (χrel) for the hydrogel and sol phases was achieved by means of the double-integration of VT-EPR spectra. PMID:26073537

  18. Statistical design and analysis of label-free LC-MS proteomic experiments: a case study of coronary artery disease.

    Science.gov (United States)

    Clough, Timothy; Braun, Siegmund; Fokin, Vladimir; Ott, Ilka; Ragg, Susanne; Schadow, Gunther; Vitek, Olga

    2011-01-01

    This chapter presents a case study, which applies statistical design and analysis to an LC-MS-based -investigation of subjects with coronary artery disease. First, we discuss the principles of statistical -experimental design, and the specification of an Analysis of Variance (ANOVA) model that describes the major sources of variation in the data. Second, we discuss procedures for detecting differentially abundant proteins, estimating protein abundance in individual samples, testing predefined groups of proteins for enrichment in differential abundance, and calculating sample size for a future experiment. The discussion is accompanied by examples of computer code implemented in the open-source statistical software R, which can be followed for an independent implementation of a similar investigation.

  19. Lipid chain-length dependence for incorporation of alamethicin in membranes: electron paramagnetic resonance studies on TOAC-spin labeled analogs.

    Science.gov (United States)

    Marsh, Derek; Jost, Micha; Peggion, Cristina; Toniolo, Claudio

    2007-06-01

    Alamethicin is a 19-residue hydrophobic peptide, which is extended by a C-terminal phenylalaninol but lacks residues that might anchor the ends of the peptide at the lipid-water interface. Voltage-dependent ion channels formed by alamethicin depend strongly in their characteristics on chain length of the host lipid membranes. EPR spectroscopy is used to investigate the dependence on lipid chain length of the incorporation of spin-labeled alamethicin in phosphatidylcholine bilayer membranes. The spin-label amino acid TOAC is substituted at residue positions n = 1, 8, or 16 in the sequence of alamethicin F50/5 [TOAC(n), Glu(OMe)(7,18,19)]. Polarity-dependent isotropic hyperfine couplings of the three TOAC derivatives indicate that alamethicin assumes approximately the same location, relative to the membrane midplane, in fluid diC(N)PtdCho bilayers with chain lengths ranging from N = 10-18. Residue TOAC(8) is situated closest to the bilayer midplane, whereas TOAC(16) is located farther from the midplane in the hydrophobic core of the opposing lipid leaflet, and TOAC(1) remains in the lipid polar headgroup region. Orientational order parameters indicate that the tilt of alamethicin relative to the membrane normal is relatively small, even at high temperatures in the fluid phase, and increases rather slowly with decreasing chain length (from 13 degrees to 23 degrees for N = 18 and 10, respectively, at 75 degrees C). This is insufficient for alamethicin to achieve hydrophobic matching. Alamethicin differs in its mode of incorporation from other helical peptides for which transmembrane orientation has been determined as a function of lipid chain length. PMID:17351010

  20. Spin-label CW microwave power saturation and rapid passage with triangular non-adiabatic rapid sweep (NARS) and adiabatic rapid passage (ARP) EPR spectroscopy

    Science.gov (United States)

    Kittell, Aaron W.; Hyde, James S.

    2015-06-01

    Non-adiabatic rapid passage (NARS) electron paramagnetic resonance (EPR) spectroscopy was introduced by Kittell et al. (2011) as a general purpose technique to collect the pure absorption response. The technique has been used to improve sensitivity relative to sinusoidal magnetic field modulation, increase the range of inter-spin distances that can be measured under near physiological conditions (Kittell et al., 2012), and enhance spectral resolution in copper (II) spectra (Hyde et al., 2013). In the present work, the method is extended to CW microwave power saturation of spin-labeled T4 Lysozyme (T4L). As in the cited papers, rapid triangular sweep of the polarizing magnetic field was superimposed on slow sweep across the spectrum. Adiabatic rapid passage (ARP) effects were encountered in samples undergoing very slow rotational diffusion as the triangular magnetic field sweep rate was increased. The paper reports results of variation of experimental parameters at the interface of adiabatic and non-adiabatic rapid sweep conditions. Comparison of the forward (up) and reverse (down) triangular sweeps is shown to be a good indicator of the presence of rapid passage effects. Spectral turning points can be distinguished from spectral regions between turning points in two ways: differential microwave power saturation and differential passage effects. Oxygen accessibility data are shown under NARS conditions that appear similar to conventional field modulation data. However, the sensitivity is much higher, permitting, in principle, experiments at substantially lower protein concentrations. Spectral displays were obtained that appear sensitive to rotational diffusion in the range of rotational correlation times of 10-3 to 10-7 s in a manner that is analogous to saturation transfer spectroscopy.

  1. Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula

    International Nuclear Information System (INIS)

    This study aimed to evaluate the feasibility of non-contrast-enhanced 4D magnetic resonance angiography (NCE 4D MRA) with signal targeting with alternative radiofrequency (STAR) spin labeling and variable flip angle (VFA) sampling in the assessment of dural arteriovenous fistula (DAVF) in the transverse sinus. Nine patients underwent NCE 4D MRA for the evaluation of DAVF in the transverse sinus at 3 T. One patient was examined twice, once before and once after the interventional treatment. All patients also underwent digital subtraction angiography (DSA) and/or contrast-enhanced magnetic resonance angiography (CEMRA). For the acquisition of NCE 4D MRA, a STAR spin tagging method was used, and a VFA sampling was applied in the data readout module instead of a constant flip angle. Two readers evaluated the NCE 4D MRA data for the diagnosis of DAVF and its type with consensus. The results were compared with those from DSA and/or CEMRA. All patients underwent NCE 4D MRA without any difficulty. Among seven patients with patent DAVFs, all cases showed an early visualization of the transverse sinus on NCE 4D MRA. Except for one case, the type of DAVF of NCE 4D MRA was agreed with that of reference standard study. Cortical venous reflux (CVR) was demonstrated in two cases out of three patients with CVR. NCE 4D MRA with STAR tagging and VFA sampling is technically and clinically feasible and represents a promising technique for assessment of DAVF in the transverse sinus. Further technical developments should aim at improvements of spatial and temporal coverage. (orig.)

  2. Probing Structural Dynamics and Topology of the KCNE1 Membrane Protein in Lipid Bilayers via Site-Directed Spin Labeling and Electron Paramagnetic Resonance Spectroscopy.

    Science.gov (United States)

    Sahu, Indra D; Craig, Andrew F; Dunagan, Megan M; Troxel, Kaylee R; Zhang, Rongfu; Meiberg, Andrew G; Harmon, Corrinne N; McCarrick, Robert M; Kroncke, Brett M; Sanders, Charles R; Lorigan, Gary A

    2015-10-20

    KCNE1 is a single transmembrane protein that modulates the function of voltage-gated potassium channels, including KCNQ1. Hereditary mutations in the genes encoding either protein can result in diseases such as congenital deafness, long QT syndrome, ventricular tachyarrhythmia, syncope, and sudden cardiac death. Despite the biological significance of KCNE1, the structure and dynamic properties of its physiologically relevant native membrane-bound state are not fully understood. In this study, the structural dynamics and topology of KCNE1 in bilayered lipid vesicles was investigated using site-directed spin labeling (SDSL) and electron paramagnetic resonance (EPR) spectroscopy. A 53-residue nitroxide EPR scan of the KCNE1 protein sequence including all 27 residues of the transmembrane domain (45-71) and 26 residues of the N- and C-termini of KCNE1 in lipid bilayered vesicles was analyzed in terms of nitroxide side-chain motion. Continuous wave-EPR spectral line shape analysis indicated the nitroxide spin label side-chains located in the KCNE1 TMD are less mobile when compared to the extracellular region of KCNE1. The EPR data also revealed that the C-terminus of KCNE1 is more mobile when compared to the N-terminus. EPR power saturation experiments were performed on 41 sites including 18 residues previously proposed to reside in the transmembrane domain (TMD) and 23 residues of the N- and C-termini to determine the topology of KCNE1 with respect to the 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC)/1-palmitoyl-2-oleoyl-sn-glycero-3-phospho-(1'-rac-glycerol) (POPG) lipid bilayers. The results indicated that the transmembrane domain is indeed buried within the membrane, spanning the width of the lipid bilayer. Power saturation data also revealed that the extracellular region of KCNE1 is solvent-exposed with some of the portions partially or weakly interacting with the membrane surface. These results are consistent with the previously published solution NMR

  3. Global Structure of a Three-Way Junction in a Phi29 Packaging RNA Dimer Determined Using Site-Directed Spin Labeling

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiaojun; Tung, Chang-Shung; Sowa, Glenna; Hatmal, Ma' mon M.; Haworth, Ian S.; Qin, Peter Z.

    2012-02-08

    The condensation of bacteriophage phi29 genomic DNA into its preformed procapsid requires the DNA packaging motor, which is the strongest known biological motor. The packaging motor is an intricate ring-shaped protein/RNA complex, and its function requires an RNA component called packaging RNA (pRNA). Current structural information on pRNA is limited, which hinders studies of motor function. Here, we used site-directed spin labeling to map the conformation of a pRNA three-way junction that bridges binding sites for the motor ATPase and the procapsid. The studies were carried out on a pRNA dimer, which is the simplest ring-shaped pRNA complex and serves as a functional intermediate during motor assembly. Using a nucleotide-independent labeling scheme, stable nitroxide radicals were attached to eight specific pRNA sites without perturbing RNA folding and dimer formation, and a total of 17 internitroxide distances spanning the three-way junction were measured using Double Electron-Electron Resonance spectroscopy. The measured distances, together with steric chemical constraints, were used to select 3662 viable three-way junction models from a pool of 65 billion. The results reveal a similar conformation among the viable models, with two of the helices (HT and HL) adopting an acute bend. This is in contrast to a recently reported pRNA tetramer crystal structure, in which HT and HL stack onto each other linearly. The studies establish a new method for mapping global structures of complex RNA molecules, and provide information on pRNA conformation that aids investigations of phi29 packaging motor and developments of pRNA-based nanomedicine and nanomaterial.

  4. Structural transitions in full-length human prion protein detected by xenon as probe and spin labeling of the N-terminal domain

    Science.gov (United States)

    Narayanan, Sunilkumar Puthenpurackal; Nair, Divya Gopalakrishnan; Schaal, Daniel; Barbosa de Aguiar, Marisa; Wenzel, Sabine; Kremer, Werner; Schwarzinger, Stephan; Kalbitzer, Hans Robert

    2016-01-01

    Fatal neurodegenerative disorders termed transmissible spongiform encephalopathies (TSEs) are associated with the accumulation of fibrils of misfolded prion protein PrP. The noble gas xenon accommodates into four transiently enlarged hydrophobic cavities located in the well-folded core of human PrP(23–230) as detected by [1H, 15N]-HSQC spectroscopy. In thermal equilibrium a fifth xenon binding site is formed transiently by amino acids A120 to L125 of the presumably disordered N-terminal domain and by amino acids K185 to T193 of the well-folded domain. Xenon bound PrP was modelled by restraint molecular dynamics. The individual microscopic and macroscopic dissociation constants could be derived by fitting the data to a model including a dynamic opening and closing of the cavities. As observed earlier by high pressure NMR spectroscopy xenon binding influences also other amino acids all over the N-terminal domain including residues of the AGAAAAGA motif indicating a structural coupling between the N-terminal domain and the core domain. This is in agreement with spin labelling experiments at positions 93 or 107 that show a transient interaction between the N-terminus and the start of helix 2 and the end of helix 3 of the core domain similar to that observed earlier by Zn2+-binding to the octarepeat motif. PMID:27341298

  5. Multidimensional High-Resolution Magic Angle Spinning and Solution-State NMR Characterization of (13)C-labeled Plant Metabolites and Lignocellulose.

    Science.gov (United States)

    Mori, Tetsuya; Tsuboi, Yuuri; Ishida, Nobuhiro; Nishikubo, Nobuyuki; Demura, Taku; Kikuchi, Jun

    2015-01-01

    Lignocellulose, which includes mainly cellulose, hemicellulose, and lignin, is a potential resource for the production of chemicals and for other applications. For effective production of materials derived from biomass, it is important to characterize the metabolites and polymeric components of the biomass. Nuclear magnetic resonance (NMR) spectroscopy has been used to identify biomass components; however, the NMR spectra of metabolites and lignocellulose components are ambiguously assigned in many cases due to overlapping chemical shift peaks. Using our (13)C-labeling technique in higher plants such as poplar samples, we demonstrated that overlapping peaks could be resolved by three-dimensional NMR experiments to more accurately assign chemical shifts compared with two-dimensional NMR measurements. Metabolites of the (13)C-poplar were measured by high-resolution magic angle spinning NMR spectroscopy, which allows sample analysis without solvent extraction, while lignocellulose components of the (13)C-poplar dissolved in dimethylsulfoxide/pyridine solvent were analyzed by solution-state NMR techniques. Using these methods, we were able to unambiguously assign chemical shifts of small and macromolecular components in (13)C-poplar samples. Furthermore, using samples of less than 5 mg, we could differentiate between two kinds of genes that were overexpressed in poplar samples, which produced clearly modified plant cell wall components. PMID:26143886

  6. Spectroscopic Evidence for Covalent Binding of Sulfadiazine to Natural Soils via 1,4-nucleophilic addition (Michael Type Addition) studied by Spin Labeling ESR

    Science.gov (United States)

    Aleksandrova, Olga

    2015-04-01

    Among different classes of veterinary pharmaceuticals, Sulfadiazine (SDZ) is widely used in animal husbandry. Its residues were detected in different environmental compartments. However, soil is a hot spot for SDZ as it receives a large portion of excreted compounds through the application of manure during soil fertilization. Ample studies on the fate of SDZ in soils showed that a large portion forms nonextractable residues (NER) along with transformation products and a low mineralization (Mueller et al., 2013). A common observation was an initially fast formation of NER up to 10% of the applied amount promptly after the application of SDZ to soil, and this portion increased up to 50% within a few days (Mueller et al., 2013; Nowak et al., 2011). A common finding for SDZ, as for other sulfonamides, was biphasic kinetics of the formation of NER, which was attributed to the occurrence of two reaction processes: a rapid, often reversible process and a slower, irreversible process (Weber et al., 1996). A single-phase reaction process was also established under anaerobic treatment (Gulkowska et al., 2014). A major focus of this work is to elucidate a reaction mechanism of covalent binding of SDZ to soil that is currently required to estimate a risk of NER formed by SDZ in soils for human health. Taking into account a key role of the amine functional groups of SDZ on its reactivity in soil, nitroxide radicals with the sewed aromatic or aliphatic amines labeled soil samples and then, were investigated by means of ESR spectroscopy. 2,5,5-Trimethyl-2-(3-aminophenyl)pyrrolidin-1-yloxy and 4-amino-2,2,6,6-Tetramethylpiperidin-1-oxyl modeled decomposition products of SDZ with the aromatic and aliphatic amines, respectively. The application of the defined combination of both spin labels (SL) to different soils well simulated a change of a paramagnetic signal of soil organic radicals interacted with SDZ. After their application to soil, SL were found in soil sites characterized

  7. Spectroscopic Evidence for Covalent Binding of Sulfadiazine to Natural Soils via 1,4-nucleophilic addition (Michael Type Addition) studied by Spin Labeling ESR

    Science.gov (United States)

    Aleksandrova, Olga

    2015-04-01

    Among different classes of veterinary pharmaceuticals, Sulfadiazine (SDZ) is widely used in animal husbandry. Its residues were detected in different environmental compartments. However, soil is a hot spot for SDZ as it receives a large portion of excreted compounds through the application of manure during soil fertilization. Ample studies on the fate of SDZ in soils showed that a large portion forms nonextractable residues (NER) along with transformation products and a low mineralization (Mueller et al., 2013). A common observation was an initially fast formation of NER up to 10% of the applied amount promptly after the application of SDZ to soil, and this portion increased up to 50% within a few days (Mueller et al., 2013; Nowak et al., 2011). A common finding for SDZ, as for other sulfonamides, was biphasic kinetics of the formation of NER, which was attributed to the occurrence of two reaction processes: a rapid, often reversible process and a slower, irreversible process (Weber et al., 1996). A single-phase reaction process was also established under anaerobic treatment (Gulkowska et al., 2014). A major focus of this work is to elucidate a reaction mechanism of covalent binding of SDZ to soil that is currently required to estimate a risk of NER formed by SDZ in soils for human health. Taking into account a key role of the amine functional groups of SDZ on its reactivity in soil, nitroxide radicals with the sewed aromatic or aliphatic amines labeled soil samples and then, were investigated by means of ESR spectroscopy. 2,5,5-Trimethyl-2-(3-aminophenyl)pyrrolidin-1-yloxy and 4-amino-2,2,6,6-Tetramethylpiperidin-1-oxyl modeled decomposition products of SDZ with the aromatic and aliphatic amines, respectively. The application of the defined combination of both spin labels (SL) to different soils well simulated a change of a paramagnetic signal of soil organic radicals interacted with SDZ. After their application to soil, SL were found in soil sites characterized

  8. Feasibility of Quantifying Arterial Cerebral Blood Volume Using Multiphase Alternate Ascending/Descending Directional Navigation (ALADDIN).

    Science.gov (United States)

    Kim, Ki Hwan; Choi, Seung Hong; Park, Sung-Hong

    2016-01-01

    Arterial cerebral blood volume (aCBV) is associated with many physiologic and pathologic conditions. Recently, multiphase balanced steady state free precession (bSSFP) readout was introduced to measure labeled blood signals in the arterial compartment, based on the fact that signal difference between labeled and unlabeled blood decreases with the number of RF pulses that is affected by blood velocity. In this study, we evaluated the feasibility of a new 2D inter-slice bSSFP-based arterial spin labeling (ASL) technique termed, alternate ascending/descending directional navigation (ALADDIN), to quantify aCBV using multiphase acquisition in six healthy subjects. A new kinetic model considering bSSFP RF perturbations was proposed to describe the multiphase data and thus to quantify aCBV. Since the inter-slice time delay (TD) and gap affected the distribution of labeled blood spins in the arterial and tissue compartments, we performed the experiments with two TDs (0 and 500 ms) and two gaps (300% and 450% of slice thickness) to evaluate their roles in quantifying aCBV. Comparison studies using our technique and an existing method termed arterial volume using arterial spin tagging (AVAST) were also separately performed in five subjects. At 300% gap or 500-ms TD, significant tissue perfusion signals were demonstrated, while tissue perfusion signals were minimized and arterial signals were maximized at 450% gap and 0-ms TD. ALADDIN has an advantage of visualizing bi-directional flow effects (ascending/descending) in a single experiment. Labeling efficiency (α) of inter-slice blood flow effects could be measured in the superior sagittal sinus (SSS) (20.8±3.7%.) and was used for aCBV quantification. As a result of fitting to the proposed model, aCBV values in gray matter (1.4-2.3 mL/100 mL) were in good agreement with those from literature. Our technique showed high correlation with AVAST, especially when arterial signals were accentuated (i.e., when TD = 0 ms) (r = 0

  9. 自旋标记查耳酮类化合物的合成及抗肿瘤活性%Synthesis and biological evaluation of spin-labelled derivatives of chalcones

    Institute of Scientific and Technical Information of China (English)

    金岩; 刘杰; 陈世武

    2013-01-01

    目的 发现高效自旋标记查耳酮类抗肿瘤药物.方法 通过乙酰苯与芳醛在碱性条件下缩合生成查耳酮,进一步与稳定氮氧自由基酸发生酰化反应合成了一系列自旋标记的查耳酮化合物,用MTT法对合成的化合物进行体外抗肿瘤活性研究(P3SS、A549、HT-29、MDA-MB-231、8GC-7901、BEL-7402).结果 化合物3a和3c在10 μg/mL时对所有测试瘤株的抑制率均大于60%.结论 自旋标记的查耳酮酰胺类化合物具有较高的体外抗肿瘤活性.%Objective To find new spin labelled chalcones as anti-tumor drugs with potent activities and low toxicities. Methods A series spin labelled chalcones were synthesized by condensation reaction of aromatic aldehyde and acetpophenone, following acetylation. The cytotoxic activities against six tumor cell lines (P388, A-549, HT-29, MDA-MB-231, SGC-7901, BEL-7402) in vitro of synthetic compounds were also evaluated by MTT method. Results Compounds 3a and 3c showed more than 60% proliferation inhibitions against all six tested tumor cell lines in vitro. Conclusion The amides of spin-labelled chalcones present better anti-tumor activities in vitro.

  10. Dynamic nuclear spin polarization

    Energy Technology Data Exchange (ETDEWEB)

    Stuhrmann, H.B. [GKSS-Forschungszentrum Geesthacht GmbH (Germany)

    1996-11-01

    Polarized neutron scattering from dynamic polarized targets has been applied to various hydrogenous materials at different laboratories. In situ structures of macromolecular components have been determined by nuclear spin contrast variation with an unprecedented precision. The experiments of selective nuclear spin depolarisation not only opened a new dimension to structural studies but also revealed phenomena related to propagation of nuclear spin polarization and the interplay of nuclear polarisation with the electronic spin system. The observation of electron spin label dependent nuclear spin polarisation domains by NMR and polarized neutron scattering opens a way to generalize the method of nuclear spin contrast variation and most importantly it avoids precontrasting by specific deuteration. It also likely might tell us more about the mechanism of dynamic nuclear spin polarisation. (author) 4 figs., refs.

  11. Cerebral metabolism and perfusion in MR-negative individuals with refractory focal epilepsy assessed by simultaneous acquisition of 18F-FDG PET and arterial spin labeling

    OpenAIRE

    Galazzo, I. B.; Mattoli, M. V.; Pizzini, F. B.; Vita, E.; Barnes, A.; Duncan, J.S.; Jager, R.; Golay, X.; Bomanji, J. B.; Koepp, M.; Groves, A M; Fraioli, F.

    2016-01-01

    The major challenge in pre-surgical epileptic patient evaluation is the correct identification of the seizure onset area, especially in MR-negative patients. In this study, we aimed to: (1) assess the concordance between perfusion, from ASL, and metabolism, from 18F-FDG, acquired simultaneously on PET/MR; (2) verify the utility of a statistical approach as supportive diagnostic tool for clinical readers. Secondarily, we compared 18F-FDG PET data from the hybrid PET/MR system with those acquir...

  12. Cerebral metabolism and perfusion in MR-negative individuals with refractory focal epilepsy assessed by simultaneous acquisition of (18)F-FDG PET and arterial spin labeling.

    Science.gov (United States)

    Boscolo Galazzo, Ilaria; Mattoli, Maria Vittoria; Pizzini, Francesca Benedetta; De Vita, Enrico; Barnes, Anna; Duncan, John S; Jäger, Hans Rolf; Golay, Xavier; Bomanji, Jamshed B; Koepp, Matthias; Groves, Ashley M; Fraioli, Francesco

    2016-01-01

    The major challenge in pre-surgical epileptic patient evaluation is the correct identification of the seizure onset area, especially in MR-negative patients. In this study, we aimed to: (1) assess the concordance between perfusion, from ASL, and metabolism, from (18)F-FDG, acquired simultaneously on PET/MR; (2) verify the utility of a statistical approach as supportive diagnostic tool for clinical readers. Secondarily, we compared (18)F-FDG PET data from the hybrid PET/MR system with those acquired with PET/CT, with the purpose of validate the reliability of (18)F-FDG PET/MR data. Twenty patients with refractory focal epilepsy, negative MR and a defined electro-clinical diagnosis underwent PET/MR, immediately followed by PET/CT. Standardized uptake value ratio (SUVr) and cerebral blood flow (CBF) maps were calculated for PET/CT-PET/MR and ASL, respectively. For all techniques, z-score of the asymmetry index (zAI) was applied for depicting significant Right/Left differences. SUVr and CBF images were firstly visually assessed by two neuroimaging readers, who then re-assessed them considering zAI for reaching a final diagnosis. High agreement between (18)F-FDG PET/MR and ASL was found, showing hypometabolism and hypoperfusion in the same hemisphere in 18/20 patients, while the remaining were normal. They were completely concordant in 14/18, concordant in at least one lobe in the remaining. zAI maps improved readers' confidence in 12/20 and 15/20 patients for (18)F-FDG PET/MR and ASL, respectively. (18)F-FDG PET/CT-PET/MR showed high agreement, especially when zAI was considered. The simultaneous metabolism-perfusion acquisition provides excellent concordance on focus lateralisation and good concordance on localisation, determining useful complementary information. PMID:27222796

  13. Balanced Steady State Free Precession for Arterial Spin Labeling MRI: Initial Experience for Blood Flow Mapping in Human Brain, Retina, and Kidney

    Science.gov (United States)

    Park, Sung-Hong; Wang, Danny J.J.; Duong, Timothy Q.

    2013-01-01

    We implemented pseudo-continuous ASL (pCASL) with 2D and 3D balanced steady state free precession (bSSFP) readout for mapping blood flow in the human brain, retina, and kidney, free of distortion and signal dropout, which are typically observed in the most commonly used echo-planar imaging acquisition. High resolution functional brain imaging in the human visual cortex was feasible with 3D bSSFP pCASL. Blood flow of the human retina could be imaged with pCASL and bSSFP in conjunction with a phase cycling approach to suppress the banding artifacts associated with bSSFP. Furthermore, bSSFP based pCASL enabled us to map renal blood flow within a single breath hold. Control and test-retest experiments suggested that the measured blood flow values in retina and kidney were reliable. Because there is no specific imaging tool for mapping human retina blood flow and the standard contrast agent technique for mapping renal blood flow can cause problems for patients with kidney dysfunction, bSSFP based pCASL may provide a useful tool for the diagnosis of retinal and renal diseases and can complement existing imaging techniques. PMID:23664680

  14. Clinical result of intra-arterial lymphocyte injection therapy for treatment of lymphedema and the evaluation of the efficacy of the therapy. Quantitative analysis by an injection of {sup 111}In-labeled lymphocytes and by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Masanori; Kitagawa, Tetsuya; Hori, Takaki; Katoh, Itsuo; Harada, Masashi; Matsumoto, Takahiro; Nishitani, Hiromu [Tokushima Univ. (Japan). School of Medicine

    1995-11-01

    We have employed the intra-arterial lymphocytes injection therapy for treatment of lymphedema of the limbs with various causes. In the present study, we observed the clinical outcome of our therapy in 38 patients with lymphedema of the limbs. Results showed that the therapy was effective in 26 of 38 patients (68% of the total). Moreover, a marked efficacy was obtained in 13 of 38 patients (34% of the total). In the latest 5 patients, to evaluate the efficacy of our therapy, we examined the distribution of the {sup 111}In-oxine labeled lymphocytes injected into the proximal artery of the affected limb. The radioactivities of the affected limbs were apparently higher than that of the healthy limbs in effective cases. Moreover, MR imaging showed that the reduction of STIR ratio and T{sub 2} ratio well correlate with the results of clinical course. Thus, the efficacy of the lymphocyte injection therapy is able to be evaluated by radiolabeled lymphocytes and MR imaging. (author).

  15. Effects of iloprost combined with low dose tadalafil in adult congenital heart disease patients with severe pulmonary arterial hypertension: a single-center,open-label controlled study

    Institute of Scientific and Technical Information of China (English)

    张曹进

    2014-01-01

    Objective To evaluate the therapy efficacy of iloprost combined with low dose tadalafil in adult congenital heart disease(CHD)patients with severe pulmonary arterial hypertension(PAH).Methods Adult CHD patients with severe PAH were included and divided into the sequential combination therapy group[iloprost:10μg/inhalation,6 times per day for 6 months,and then add oral tadalafil(5 mg/d)till 12 months,n=32]and upfront combination therapy group[iloprost:10μg/inhalation,6 times per day combined with oral tadalafil(5 mg)

  16. Food Labels

    Science.gov (United States)

    ... How Can I Help a Friend Who Cuts? Food Labels KidsHealth > For Teens > Food Labels Print A ... have at least 95% organic ingredients. continue Making Food Labels Work for You The first step in ...

  17. Nano-Mole Scale Side-Chain Signal Assignment by 1H-Detected Protein Solid-State NMR by Ultra-Fast Magic-Angle Spinning and Stereo-Array Isotope Labeling

    KAUST Repository

    Wang, Songlin

    2015-04-09

    We present a general approach in 1H-detected 13C solid-state NMR (SSNMR) for side-chain signal assignments of 10-50 nmol quantities of proteins using a combination of a high magnetic field, ultra-fast magic-angle spinning (MAS) at ~80 kHz, and stereo-array-isotope-labeled (SAIL) proteins [Kainosho M. et al., Nature 440, 52–57, 2006]. First, we demonstrate that 1H indirect detection improves the sensitivity and resolution of 13C SSNMR of SAIL proteins for side-chain assignments in the ultra-fast MAS condition. 1H-detected SSNMR was performed for micro-crystalline ubiquitin (~55 nmol or ~0.5mg) that was SAIL-labeled at seven isoleucine (Ile) residues. Sensitivity was dramatically improved by 1H-detected 2D 1H/13C SSNMR by factors of 5.4-9.7 and 2.1-5.0, respectively, over 13C-detected 2D 1H/13C SSNMR and 1D 13C CPMAS, demonstrating that 2D 1H-detected SSNMR offers not only additional resolution but also sensitivity advantage over 1D 13C detection for the first time. High 1H resolution for the SAIL-labeled side-chain residues offered reasonable resolution even in the 2D data. A 1H-detected 3D 13C/13C/1H experiment on SAIL-ubiquitin provided nearly complete 1H and 13C assignments for seven Ile residues only within ~2.5 h. The results demonstrate the feasibility of side-chain signal assignment in this approach for as little as 10 nmol of a protein sample within ~3 days. The approach is likely applicable to a variety of proteins of biological interest without any requirements of highly efficient protein expression systems.

  18. Hepatic artery injection of {sup 131}I-labelled metuximab combined with chemoembolization for intermediate hepatocellular carcinoma: a prospective nonrandomized study

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Lu; Yang, Ye-Fa; Ge, Nai-Jian; Shen, Shu-Qun; Liang, Jun [Second Military Medical University, The First Department of Interventional Radiology, Eastern Hepatobiliary Surgery Hospital, Shanghai (China); Wang, Yi [Second Military Medical University, The Second Department of Hepatic Surgery, Eastern Hepatobiliary Surgery Hospital, Shanghai (China); Zhou, Wei-Ping [Second Military Medical University, The Third Department of Hepatic Surgery, Eastern Hepatobiliary Surgery Hospital, Shanghai (China); Shen, Feng; Wu, Meng-Chao [Second Military Medical University, Eastern Hepatobiliary Surgery Hospital, Shanghai (China)

    2012-08-15

    Hepatocellular carcinoma (HCC) is the fifth and seventh most common cause of cancer in men and women, respectively. Transcatheter arterial chemoembolization (TACE) is the standardized therapy for the intermediate stage of HCC. However, the 3-year overall survival remains low (<30 %) in these patients. Thus, there is a critical need for the development of treatment modalities to improve the survival rate. This study aimed to evaluate whether the combination of {sup 131}I-metuximab with chemoembolization could improve treatment efficiency. Between January 2009 and January 2010, a prospective two-arm nonrandomized study was performed in patients with intermediate HCC. Of 138 patients, 68 (combination therapy group) received 132 courses of intraarterial {sup 131}I-metuximab injections combined with chemoembolization (mean 1.94 per patient, median 2, range 1-2), followed by 152 sessions of TACE (mean 2.24 per patient, median 2, range 0-4). The remaining 70 patients (monotherapy group) received 296 sessions of TACE (mean 4.23 per patient, median 4, range 1-7). The overall median survival times for the combination therapy group and the group treated only with TACE were 26.7 months (95 % CI 20.7-31.3 months) and 20.6 months (95 % CI 15.3-24.7 months), respectively. The combination therapy group had a significantly higher survival rate than the TACE-only group (P = 0.038). Age {>=}65 years, serum albumin {<=}35 g/l, and treatment category (combination therapy or TACE only) were independent prognostic factors for survival according to multivariate analysis. The combination of {sup 131}I-metuximab and chemoembolization extended survival in patients with intermediate HCC compared with TACE only, and was well tolerated by patients with Child-Pugh class A or B disease. This combination seems to be a promising treatment modality for patients with intermediate HCC. (orig.)

  19. Spin foams without spins

    Science.gov (United States)

    Hnybida, Jeff

    2016-10-01

    We formulate the spin foam representation of discrete SU(2) gauge theory as a product of vertex amplitudes each of which is the spin network generating function of the boundary graph dual to the vertex. In doing so the sums over spins have been carried out. The boundary data of each n-valent node is explicitly reduced with respect to the local gauge invariance and has a manifest geometrical interpretation as a framed polyhedron of fixed total area. Ultimately, sums over spins are traded for contour integrals over simple poles and recoupling theory is avoided using generating functions.

  20. Operator Spin Foam Models

    CERN Document Server

    Bahr, Benjamin; Kamiński, Wojciech; Kisielowski, Marcin; Lewandowski, Jerzy

    2010-01-01

    The goal of this paper is to introduce a systematic approach to spin foams. We define operator spin foams, that is foams labelled by group representations and operators, as the main tool. An equivalence relation we impose in the set of the operator spin foams allows to split the faces and the edges of the foams. The consistency with that relation requires introduction of the (familiar for the BF theory) face amplitude. The operator spin foam models are defined quite generally. Imposing a maximal symmetry leads to a family we call natural operator spin foam models. This symmetry, combined with demanding consistency with splitting the edges, determines a complete characterization of a general natural model. It can be obtained by applying arbitrary (quantum) constraints on an arbitrary BF spin foam model. In particular, imposing suitable constraints on Spin(4) BF spin foam model is exactly the way we tend to view 4d quantum gravity, starting with the BC model and continuing with the EPRL or FK models. That makes...

  1. Arterial Ageing

    OpenAIRE

    Lee, Seung-Jun; Park, Sung-Ha

    2013-01-01

    Arterial ageing is characterized by age associated degeneration and sclerosis of the media layer of the large arteries. However, besides ageing, clinical conditions, which enhance oxidative stress and inflammation act to accelerate the degree of arterial ageing. In this review, we summarized the pathophysiology and contributing factors that accelerate arterial ageing. Among them, we focused on hypertension, the renin-angiotensin-aldosterone system and vascular inflammation which are modifiabl...

  2. Nutrition Labeling

    DEFF Research Database (Denmark)

    Grunert, Klaus G

    2013-01-01

    because consumers will avoid products that the label shows to be nutritionally deficient, but also because food producers will try to avoid marketing products that appear, according to the label, as nutritionally problematic, for example, because of a high content of saturated fat or salt. Nutrition......Nutrition labeling refers to the provision of information on a food product’s nutritional content on the package label. It can serve both public health and commercial purposes. From a public health perspective, the aim of nutrition labeling is to provide information that can enable consumers...... to make healthier choices when choosing food products. Nutrition labeling is thus closely linked to the notion of the informed consumer, that chooses products according to their aims, on the basis of the information at their disposal. Because many consumers are assumed to be interested in making healthy...

  3. Spin current

    CERN Document Server

    Valenzuela, Sergio O; Saitoh, Eiji; Kimura, Takashi

    2012-01-01

    In a new branch of physics and technology called spin-electronics or spintronics, the flow of electrical charge (usual current) as well as the flow of electron spin, the so-called 'spin current', are manipulated and controlled together. This book provides an introduction and guide to the new physics and application of spin current.

  4. Tensorial Spin-s Harmonics

    OpenAIRE

    Newman, Ezra T.; Silva-Ortigoza, Gilberto

    2005-01-01

    We show how to define and go from the spin-s spherical harmonics to the tensorial spin-s harmonics. These quantities, which are functions on the sphere taking values as Euclidean tensors, turn out to be extremely useful for many calculations in General Relativity. In the calculations, products of these functions, with their needed decompositions which are given here, often arise naturally.

  5. Food labeling

    Science.gov (United States)

    ... per serving to the right of the nutrient. Vitamins and minerals: Only two vitamins (A and C) and two ... are required on the food label. But, when vitamins or minerals are added to the food, or when a ...

  6. A multimodal imaging study on spatial pattern of cerebral perfusion change caused by symptomatic unilateral carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Jian-rui LI

    2015-03-01

    Full Text Available Objective To investigate the spatial pattern of cerebral perfusion decrease resulting from symptomatic unilateral carotid artery stenosis and to assess the relationship between degrees of stenosis and cerebral blood flow (CBF.  Methods CT angiography (CTA and arterial spin labeling (ASL MRI cerebral perfusion were performed in 22 patients with symptomatic unilateral carotid artery stenosis. Diagnosis of carotid artery stenosis and measurement of stenosis degrees was performed by using CTA; cerebral perfusion was determined by ASL. Voxel-based analysis (VBA were applied to observe perfusion changes in patients with mild stenosis and moderate to severe stenosis, and spatial pattern of cerebral perfusion changes caused by carotid artery stenosis. Analysis based on region of interest (ROI was used to explore the relationship between degrees of stenosis and CBF. Results Twenty-two patients with symptomatic unilateral carotid artery stenosis (13 in the left side and 9 in the right included 13 cases with mild stenosis and 9 cases with moderate to severe stenosis. Compared to those with mild stenosis, patients with moderate to severe stenosis showed reduced CBF in bilateral (especially in the affected side parietal lobes (t = - 2.382, P = 0.014, frontal lobes (t = - 2.354, P = 0.015 and centrum semiovale (t = - 2.283, P = 0.017, and was basically located in bilateral cerebral watershed area. Furthermore, perfusion in these areas was negatively correlated with the degree of stenosis (r = - 0.479, P = 0.024.  Conclusions Symptomatic unilateral carotid artery stenosis may result in cerebral perfusion decreases in bilateral (particularly in the affected side watershed area and cerebral blood flow is negatively correlated with the degree of stenosis. DOI: 10.3969/j.issn.1672-6731.2015.02.006

  7. Food labels

    DEFF Research Database (Denmark)

    Selsøe Sørensen, Henrik; Clement, Jesper; Gabrielsen, Gorm

    2012-01-01

    The food industry develops tasty and healthy food but fails to deliver the message to all consumers. The consumers’ background knowledge is essential for how they find and decode relevant elements in the cocktail of signs which fight for attention on food labels. In this exploratory study, we find...... evidence for dividing consumers into two profiles: one relying on general food knowledge and another using knowledge related to signpost labels. In a combined eyetracking and questionnaire survey we analyse the influence of background knowledge and identify different patterns of visual attention...... for the two consumer profiles. This underlines the complexity in choosing and designing the ‘right’ elements for a food package that consumers actually look at and are able to make rational use of. In spite of any regulation of food information provided by authorities, consumers will still be confronted...

  8. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  9. MR imaging of persistent primitive trigeminal artery

    Energy Technology Data Exchange (ETDEWEB)

    Ashikaga, Ryuichiro; Araki, Yutaka; Ono, Yukihiko; Ishida, Osamu [Kinki Univ., Higashi-Osaka, Osaka (Japan); Mabuchi, Nobuhisa

    1997-02-01

    The persistent trigeminal artery is the most common anomaly of the primitive carotid-vertebrobasilar anastomoses. We reviewed MR images and MR angiographies of 11 patients with primitive trigeminal artery. In 8 of the 11 cases, PTA were identified with conventional long TR spin-echo images. In 8 of 11 cases, a hypoplastic basilar trunk associated with PTA was seen on both MR images and MR angiographies. In 7 of 11 cases, a hypoplasia or agenesis of the ipsilateral posterior communicating artery was seen on MR angiographies. (author)

  10. Carotid Artery Screening

    Science.gov (United States)

    ... Resources Professions Site Index A-Z Carotid Artery Screening What is carotid artery screening? Who should consider ... about carotid artery screening? What is carotid artery screening? Screening examinations are tests performed to find disease ...

  11. Spin glasses

    CERN Document Server

    Bovier, Anton

    2007-01-01

    Spin glass theory is going through a stunning period of progress while finding exciting new applications in areas beyond theoretical physics, in particular in combinatorics and computer science. This collection of state-of-the-art review papers written by leading experts in the field covers the topic from a wide variety of angles. The topics covered are mean field spin glasses, including a pedagogical account of Talagrand's proof of the Parisi solution, short range spin glasses, emphasizing the open problem of the relevance of the mean-field theory for lattice models, and the dynamics of spin glasses, in particular the problem of ageing in mean field models. The book will serve as a concise introduction to the state of the art of spin glass theory, usefull to both graduate students and young researchers, as well as to anyone curious to know what is going on in this exciting area of mathematical physics.

  12. In vivo quantification of hyperoxic arterial blood water T1.

    Science.gov (United States)

    Siero, Jeroen C W; Strother, Megan K; Faraco, Carlos C; Hoogduin, Hans; Hendrikse, Jeroen; Donahue, Manus J

    2015-11-01

    Normocapnic hyperoxic and hypercapnic hyperoxic gas challenges are increasingly being used in cerebrovascular reactivity (CVR) and calibrated functional MRI experiments. The longitudinal arterial blood water relaxation time (T1a) change with hyperoxia will influence signal quantification through mechanisms relating to elevated partial pressure of plasma-dissolved O2 (pO2) and increased oxygen bound to hemoglobin in arteries (Ya) and veins (Yv). The dependence of T1a on Ya and Yv has been elegantly characterized ex vivo; however, the combined influence of pO2, Ya and Yv on T1a in vivo under normal ventilation has not been reported. Here, T1a is calculated during hyperoxia in vivo by a heuristic approach that evaluates T1 -dependent arterial spin labeling (ASL) signal changes to varying gas stimuli. Healthy volunteers (n = 14; age, 31.5 ± 7.2 years) were scanned using pseudo-continuous ASL in combination with room air (RA; 21% O2/79% N2), hypercapnic normoxic (HN; 5% CO2/21% O2/74% N2) and hypercapnic hyperoxic (HH; 5% CO2/95% O2) gas administration. HH T1a was calculated by requiring that the HN and HH cerebral blood flow (CBF) change be identical. The HH protocol was then repeated in patients (n = 10; age, 61.4 ± 13.3 years) with intracranial stenosis to assess whether an HH T1a decrease prohibited ASL from being performed in subjects with known delayed blood arrival times. Arterial blood T1a decreased from 1.65 s at baseline to 1.49 ± 0.07 s during HH. In patients, CBF values in the affected flow territory for the HH condition were increased relative to baseline CBF values and were within the physiological range (RA CBF = 36.6 ± 8.2 mL/100 g/min; HH CBF = 45.2 ± 13.9 mL/100 g/min). It can be concluded that hyperoxic (95% O2) 3-T arterial blood T1aHH = 1.49 ± 0.07 s relative to a normoxic T1a of 1.65 s. PMID:26419505

  13. Positron emission tomography/magnetic resonance hybrid scanner imaging of cerebral blood flow using 15O-water positron emission tomography and arterial spin labeling magnetic resonance imaging in newborn piglets

    DEFF Research Database (Denmark)

    Andersen, Julie B; Henning, William S; Lindberg, Ulrich;

    2015-01-01

    Abnormality in cerebral blood flow (CBF) distribution can lead to hypoxic-ischemic cerebral damage in newborn infants. The aim of the study was to investigate minimally invasive approaches to measure CBF by comparing simultaneous (15)O-water positron emission tomography (PET) and single TI pulsed...

  14. Application of interictal arterial spin labeling MR perfusion in intractable mesial temporal lobe epilepsy%动脉自旋标记在难治性颞叶内侧癫痫发作间期的应用

    Institute of Scientific and Technical Information of China (English)

    孙泓泓; 吕长磊; 白芝兰; 张晓娜; 师莉芳

    2012-01-01

    Objective To determine whether pulsed ASL(PASL) MR] using flow-sensitive alternating inversion recovery) FAIR) could be a useful clinical tool to detect intcrictal temporal hypopcrfusion in mesial temporal lobe cpilcpsy(TLEl) ,thcn on the base of changes of cerebral blood flow(CBF) to determine the seizure focus. Methods 15 normal controls and 15 patients were studied by using a FAIR pcrfusion mode to measure the CBF of mesial temporal lobe. According to the vidco-clcctrocnccphalography ( VEEG) findings, the origin sides of seizure were obtained in all patients. Results Pcrfusion in control participants was ( 167. 95 ± 15. 30) mL/( 100 g · min) on the right and (169.64 ± 13.24) mL/( 100 g · min) on the left. In patients, mesial temporal lobe pcrfusion was (158.42 ± 9.09) mL/(100 g- min) on the ipsilatcral (affected) side and (170. 11±7. 67) mL/(100 g · min) on the contralatcral (unaffected) side. The blood flow measurements were significantly different in ipsilatcral versus contralatcral sides in patients. In control participants, the mean absolute asymmetry index was 2. 49 ± 2. 09. For the patients, mean absolute asymmetry index was 7. 20 ± 4. 21. The difference was statistically significant P = 0. 001 ). The coefficient of agreement for detecting the asymmetry with FAIR and with vidco-EEG latcralization was 80%. Conclusion MR pcrfusion imaging based on the FAIR technique is capable of detecting intcrictal hypopcrfusion of mesial temporal lobe in patients with medically refractory temporal lobe epilepsy and provides complementary information to tests that assess structure.%目的 明确流动敏感交互反转恢复模式(FAIR)的脉冲式动脉自旋标记(PASL)能否检测出发作间期颞叶内侧的低灌注,根据脑血流灌注变化确定致痫灶位置.方法 15例经过视频脑电图(VEEG)确诊的颞叶癫痫(TLE)病人和15例正常对照者行FAIR测量感兴趣区脑血流量(CBF)并计算相关数值.结果 对照组左、右颞叶内侧灌注分别是(169.64±13.24) mL/(100 g·min)、(167.95±15.30) mL/(100 g·min).病例组致痫灶同侧与对侧颞叶内侧灌注分别是(158.42±9.09) mL/(100 g·min)、(170.11±7.67) mL/(100 g·min),两侧颞叶内侧血流量明显不同.对照组和病例组颞叶内侧灌注的不对称指数分别为2.49±2.09、7.20±4.21.虽然对照组颞叶内侧CBF也存在不对称性,病例组颞叶内侧CBF不对称指数(AI)明显大于对照组,AI差别存在统计学差异(P=0.001).FAIR和VEEG对致痫灶定侧一致率达80%.结论 FAIR 灌注成像可以检测出难治性TLE病人发作间期颞叶内侧CBF灌注减低,是对结构评估的有益补充.

  15. Progresses of arterial spin labeling MRI in mesial temporal lobe epilepsy%动脉自旋标记技术在内侧颞叶癫痫中的应用进展

    Institute of Scientific and Technical Information of China (English)

    郭小琴; 赵斌; 王光彬

    2014-01-01

    内侧颞叶癫痫(MTLE)为致痫灶起源于内侧颞叶并可伴有海马硬化的一类癫痫,随着新技术的开发与应用,影像学检查在改善其临床诊断与治疗中发挥着越来越大的作用.动脉自旋标记(ASL)是一种无创的MR成像技术.本文对ASL在MTLE相关基础研究与临床应用中的进展进行综述.

  16. Spin electronics

    CERN Document Server

    Buhrman, Robert; Daughton, James; Molnár, Stephan; Roukes, Michael

    2004-01-01

    This report is a comparative review of spin electronics ("spintronics") research and development activities in the United States, Japan, and Western Europe conducted by a panel of leading U.S. experts in the field. It covers materials, fabrication and characterization of magnetic nanostructures, magnetism and spin control in magnetic nanostructures, magneto-optical properties of semiconductors, and magnetoelectronics and devices. The panel's conclusions are based on a literature review and a series of site visits to leading spin electronics research centers in Japan and Western Europe. The panel found that Japan is clearly the world leader in new material synthesis and characterization; it is also a leader in magneto-optical properties of semiconductor devices. Europe is strong in theory pertaining to spin electronics, including injection device structures such as tunneling devices, and band structure predictions of materials properties, and in development of magnetic semiconductors and semiconductor heterost...

  17. Imaging of early carotid artery atherosclerotic lesions with {sup 111}In-labeled polyclonalhuman IgG (HIG); Darstellung frueher atherosklerotischer Laesionen der A. carotis mit {sup 111}In-markiertem polyklonalen humanem IgG (HIG)

    Energy Technology Data Exchange (ETDEWEB)

    Kritz, H. [Wilhelm-Auerswald-Atherioskleroseforschungsgruppe (ASF), Wien (Austria); Rodrigues, M.; Sinzinger, H. [Universitaetsklinik fuer Nuklearmedizin, Wien (Austria)]|[Wilhelm-Auerswald-Atherioskleroseforschungsgruppe (ASF), Wien (Austria)

    1997-12-01

    To assess the value of scintigraphy with {sup 111}In-HIG for diagnosis and evaluation of the stage and the clinical extent of carotid artery disease in humans a prospective clinical comparative trial of scintigraphy vs. sonography was performed. 58 patients (38 male, 20 female; mean age 60{+-}7 years) with hyperlipidemia and ultrasonographically detectable carotid artery lesions were studied. After i.v. injection of 18.5 MBq {sup 111}In-HIG, anterior scintigraphic images of the neck were acquired. Real time two-dimensional B-mode ultrasonography of the left and the right carotid arteries was performed. {sup 111}In-HIG-scintigraphy as compared to the morphological gold standard (ultrasonography) had a sensitivity of 70-73%, specificity of 33-41% and a positive predictive value of 77-82% for detecting carotid atherosclerotic lesions. There was, however, no significant correlation between scintigraphy and ultrasonography. However, the data provide evidence that the two imaging techniques are visualizing different aspects of atherogenesis. On the one hand a functional one reflecting the activity of the disease ({sup 111}In-HIG) and on the other hand the morphological one resembling the extent of the disease (ultrasonography). (orig.) [Deutsch] Zur Erfassung morphologischer und funktioneller Veraenderungen bei fruehen atherosklerotischen Gefaessveraenderungen wurde in der vorliegenden prospektiven Vergleichsstudie die Wertigkeit der Szintigraphie mit {sup 111}In-markiertem humanem Immunglobulin G ({sup 111}In-HIG) im Vergleich zur hochaufloesenden Sonographie verglichen. 58 Patienten (38 Maenner, 20 Frauen; mittleres Alter 60{+-}7 Jahre) mit einer Dyslipoproteinaemie und sonographisch nachgewiesenen atherosklerotischen Laesionen der A. carotis wurden untersucht. Nach i.v. Applikation von 18,5 MBq {sup 111}In-HIG wurden a.p. Szintigramme der Halsregion angefertigt. Weiter wurde eine zweidimensionale Realtime-B-Mode-Sonographie der linken und rechten Arteria carotis

  18. Angioplasty and stent placement -- peripheral arteries

    Science.gov (United States)

    Percutaneous transluminal angioplasty - peripheral artery; PTA - peripheral artery; Angioplasty - peripheral arteries; Iliac artery -angioplasty; Femoral artery - angioplasty; Popliteal artery - angioplasty; Tibial ...

  19. Spin-Orbit induced semiconductor spin guides

    OpenAIRE

    Valin-Rodriguez, Manuel; Puente, Antonio; Serra, Llorens

    2002-01-01

    The tunability of the Rashba spin-orbit coupling allows to build semiconductor heterostructures with space modulated coupling intensities. We show that a wire-shaped spin-orbit modulation in a quantum well can support propagating electronic states inside the wire only for a certain spin orientation and, therefore, it acts as an effective spin transmission guide for this particular spin orientation.

  20. Carotid Artery Disease

    Science.gov (United States)

    ... brain with blood. If you have carotid artery disease, the arteries become narrow, usually because of atherosclerosis. ... one of the causes of stroke. Carotid artery disease often does not cause symptoms, but there are ...

  1. Peripheral arterial line (image)

    Science.gov (United States)

    A peripheral arterial line is a small, short plastic catheter placed through the skin into an artery of the arm or leg. The purpose of a peripheral arterial line is to allow continuous monitoring of ...

  2. Ivabradine: A Review of Labeled and Off-Label Uses.

    Science.gov (United States)

    Oliphant, Carrie S; Owens, Ryan E; Bolorunduro, Oluwaseyi B; Jha, Sunil K

    2016-10-01

    Ivabradine is a unique medication recently approved in the USA for the treatment of select heart failure patients. It was first approved for use in several countries around the world over a decade ago as an anti-anginal agent, with subsequent approval for use in heart failure patients. Since ivabradine has selective activity blocking the I f currents in the sinus node, it can reduce heart rate without appreciable effects on blood pressure. Given this heart-rate-specific effect, it has been investigated in many off-label indications as an alternative to traditional heart-rate-reducing medications such as beta blockers and calcium channel blockers. We conducted searches of PubMed and Google Scholar for ivabradine, heart failure, HFrEF, HFpEF, angina, coronary artery disease, inappropriate sinus tachycardia, postural orthostatic hypotension, coronary computed tomography angiography and atrial fibrillation. We reviewed and included studies, case reports, and case series published between 1980 and June 2016 if they provided information relevant to the practicing clinician. In many cases, larger clinical trials are needed to solidify the benefit of ivabradine, although studies indicate benefit in most therapeutic areas explored to date. The purpose of this paper is to review the current labeled and off-label uses of ivabradine, with a focus on clinical trial data. PMID:27405864

  3. Issues in Data Labelling

    NARCIS (Netherlands)

    Cowie, Roddy; Cox, Cate; Martin, Jeam-Claude; Batliner, Anton; Heylen, Dirk; Karpouzis, Kostas; Cowie, Roddy; Pelachaud, Catherine; Petta, Paolo

    2011-01-01

    Labelling emotion databases is not a purely technical matter. It is bound up with theoretical issues. Different issues affect labelling of emotional content, labelling of the signs that convey emotion, and labelling of the relevant context. Linked to these are representational issues, involving time

  4. Electron spin resonance studies on reduction process of nitroxyl spin radicals used in molecular imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dhas, M. Kumara; Benial, A. Milton Franklin, E-mail: miltonfranklin@yahoo.com [Department of Physics, NMSSVN College, Nagamalai, Madurai-625019, Tamilnadu (India); Jawahar, A. [Department of Chemistry, NMSSVN College, Nagamalai, Madurai-625019, Tamilnadu (India)

    2014-04-24

    The Electron spin resonance studies on the reduction process of nitroxyl spin probes were carried out for 1mM {sup 14}N labeled nitroxyl radicals in pure water and 1 mM concentration of ascorbic acid as a function of time. The electron spin resonance parameters such as signal intensity ratio, line width, g-value, hyperfine coupling constant and rotational correlation time were determined. The half life time was estimated for 1mM {sup 14}N labeled nitroxyl radicals in 1 mM concentration of ascorbic acid. The ESR study reveals that the TEMPONE has narrowest line width and fast tumbling motion compared with TEMPO and TEMPOL. From the results, TEMPONE has long half life time and high stability compared with TEMPO and TEMPOL radical. Therefore, this study reveals that the TEMPONE radical can act as a good redox sensitive spin probe for molecular imaging.

  5. Electron spin resonance studies on reduction process of nitroxyl spin radicals used in molecular imaging

    International Nuclear Information System (INIS)

    The Electron spin resonance studies on the reduction process of nitroxyl spin probes were carried out for 1mM 14N labeled nitroxyl radicals in pure water and 1 mM concentration of ascorbic acid as a function of time. The electron spin resonance parameters such as signal intensity ratio, line width, g-value, hyperfine coupling constant and rotational correlation time were determined. The half life time was estimated for 1mM 14N labeled nitroxyl radicals in 1 mM concentration of ascorbic acid. The ESR study reveals that the TEMPONE has narrowest line width and fast tumbling motion compared with TEMPO and TEMPOL. From the results, TEMPONE has long half life time and high stability compared with TEMPO and TEMPOL radical. Therefore, this study reveals that the TEMPONE radical can act as a good redox sensitive spin probe for molecular imaging

  6. Cavity spin optodynamics

    CERN Document Server

    Brahms, N

    2010-01-01

    The dynamics of a large quantum spin coupled parametrically to an optical resonator is treated in analogy with the motion of a cantilever in cavity optomechanics. New spin optodynamic phenonmena are predicted, such as cavity-spin bistability, optodynamic spin-precession frequency shifts, coherent amplification and damping of spin, and the spin optodynamic squeezing of light.

  7. Using Markov models to simulate electron spin resonance spectra from molecular dynamics trajectories

    OpenAIRE

    Sezer, Deniz; Freed, Jack H.; Roux, Benoît

    2008-01-01

    Simulating electron spin resonance (ESR) spectra directly from molecular dynamics simulations of a spin labeled protein necessitates a large number (hundreds or thousands) of relatively long (hundreds of ns) trajectories. To meet this challenge, we explore the possibility of constructing accurate stochastic models of the spin label dynamics from atomistic trajectories. A systematic, two-step procedure, based on the probabilistic framework of hidden Markov models, is developed to build a discr...

  8. MR imaging findings of renal infarction induced by renal artery

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun Woo; Kim, Suck; Kim, Yong Woo; Hu, Jin Sam; Choi, Sang Yoel; Moon, Tae Yong; Lee, Suck Hong; Kim, Byung Su; Lee, Chang Hun [Pusan National Univ., Pusan (Korea, Repulic of). Coll. of Medicine

    1998-02-01

    To assess the usefulness of diffusion-weighted imaging (DWI) in evaluating serial parenchymal changes in renal infarction induced by renal artery ligation, by comparing this with the conventional spin echo technique and correlating the results with the histopathological findings. In 22 rabbits, renal infarction was induced by ligation of the renal artery. Spin-echo T1-weighted imaging (T1WI), turbo spin-echo (TSE) T2-weighted imaging (T2WI), and DWI were performed, using a 1.5-T superconductive unit, at 30 minutes, 1 hour, 2,3,6, 12 and 24 hours, and 2, 3, 7 and 20 days after left renal artery ligation. Changes in signal intensity on T1WI, T2WI, and DWI were correlated with histopathologic findings. Diffusion-weighted imaging is useful for the detection of hyperacute renal infarction, and the apparent diffusion coefficient may provide additional information concerning its evolution. (author). 21 refs., 9 figs.

  9. Mean arterial pressure change associated with cerebral blood flow in healthy older adults.

    Science.gov (United States)

    Deverdun, Jeremy; Akbaraly, Tasnime N; Charroud, Celine; Abdennour, Meriem; Brickman, Adam M; Chemouny, Stephane; Steffener, Jason; Portet, Florence; Bonafe, Alain; Stern, Yaakov; Ritchie, Karen; Molino, François; Le Bars, Emmanuelle; Menjot de Champfleur, Nicolas

    2016-10-01

    We investigate over a 12-year period the association between regional cerebral blood flow (CBF) and cardiovascular risk factors in a prospective cohort of healthy older adults (81.96 ± 3.82 year-old) from the Cognitive REServe and Clinical ENDOphenotype (CRESCENDO) study. Cardiovascular risk factors were measured over 12 years, and gray matter CBF was measured at the end of the study from high-resolution magnetic resonance imaging using arterial spin labeling. The association between cardiovascular risk factors, their long-term change, and CBF was assessed using multivariate linear regression models. Women were observed to have higher CBF than men (p < 0.05). Increased mean arterial pressure (MAP) over the 12-year period was correlated with a low cerebral blood flow (p < 0.05, R(2) = 0.21), whereas no association was detected between CBF and MAP at the time of imaging. High levels of glycemia tended to be associated with low cerebral blood flow values (p < 0.05). Age, alcohol consumption, smoking status, body mass index, history of cardiovascular disease, and hypertension were not associated with CBF. Our main result suggests that change in MAP is the most significant predictor of future CBF in older adults.

  10. [Abnormal popliteal arteries].

    Science.gov (United States)

    Elbaz, C

    1975-01-01

    Arteriopathy restricted to the popliteal artery, except in cases of atheroma, must indicate three of four unusual diagnoses: the trapped popliteal artery and the dessicating haematoma are anatomo-clinical entities that have been identified only relatively recently. The popliteal artery may be trapped by the medial gastrocnomius muscle, round the tendon of which the artery passes (totally or partially). This results in compression of the artery and eventually in thrombosis. Clinically, intermittent claudication is seen that may deteriorate and lead to gangrene of the toes. Arteriography makes it possible to diagnose the condition as the condition as the artery is considerably displaced inwards. Surgical correction is simple: sectioning of the tendon and repositioning of the artery. Dessicating haematoma of the popliteal artery is due essentially to atheroma, associated with medianecrosis. A "egg-timer" stenosis is found by arteriography and this condition also progresses towards thrombosis. Arterial restoration is called for, usually by bridging. PMID:1230799

  11. Pesticide Product Label System

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Pesticide Product Label System (PPLS) provides a collection of pesticide product labels (Adobe PDF format) that have been approved by EPA under Section 3 of the...

  12. Mental Labels and Tattoos

    Science.gov (United States)

    Hyatt, I. Ralph

    1977-01-01

    Discusses the ease with which mental labels become imprinted in our system, six basic axioms for maintaining negative mental tattoos, and psychological processes for eliminating mental tattoos and labels. (RK)

  13. Semiotic labelled deductive systems

    Energy Technology Data Exchange (ETDEWEB)

    Nossum, R.T. [Imperial College of Science, Technology and Medicine, London (United Kingdom)

    1996-12-31

    We review the class of Semiotic Models put forward by Pospelov, as well as the Labelled Deductive Systems developed by Gabbay, and construct an embedding of Semiotic Models into Labelled Deductive Systems.

  14. Spin injection into semiconductors

    Science.gov (United States)

    Oestreich, M.; Hübner, J.; Hägele, D.; Klar, P. J.; Heimbrodt, W.; Rühle, W. W.; Ashenford, D. E.; Lunn, B.

    1999-03-01

    The injection of spin-polarized electrons is presently one of the major challenges in semiconductor spin electronics. We propose and demonstrate a most efficient spin injection using diluted magnetic semiconductors as spin aligners. Time-resolved photoluminescence with a Cd0.98Mn0.02Te/CdTe structure proves the feasibility of the spin-alignment mechanism.

  15. Spin noise in mixed Spin Systems

    Science.gov (United States)

    Bauch, Erik; Junghyun, Paul; Singh, Swati; Devakul, Trithep; Feguin, Adrian; Hart, Connor; Walsworth, Ronald

    2016-05-01

    The spin noise due to interaction of multiple spin species in mixed spin systems provides a fundamental limit to ultra-sensitive ensemble sensing and quantum information applications. In our work, we investigate the interaction of dense nuclear 13C spins with electronic nitrogen spins using Nitrogen-Vacancy centers in diamond. Our work shows experimentally and theoretically, that under certain conditions, spin noise is greatly suppressed and the coherence time of NV centers improved by order of magnitudes, providing a pathway to engineering high density ensemble samples with long coherence times at room temperature.

  16. Detection of pulmonary hemorrhage with technetium-labeled red cells

    Energy Technology Data Exchange (ETDEWEB)

    Winzelberg, G.G.; Laman, D.; Sachs, M.; Miller, W.H.

    1981-10-01

    Noninvasive techniques to aid in the diagnosis of massive pulmonary hemoptysis would be helpful in guiding more-invasive procedures such as bronchial artery angiography, which carries a risk of transverse myelitis. A patient was studied with technetium-labeled red cells and successfully detected a site of intermittent hemorrhage from the lung.

  17. Detection of pulmonary hemorrhage with technetium-labeled red cells

    International Nuclear Information System (INIS)

    Noninvasive techniques to aid in the diagnosis of massive pulmonary hemoptysis would be helpful in guiding more-invasive procedures such as bronchial artery angiography, which carries a risk of transverse myelitis. A patient was studied with technetium-labeled red cells and successfully detected a site of intermittent hemorrhage from the lung

  18. The efficacy and safety of bosentan therapy for Chinese patients with idiopathic pulmonary arterial hypertension:an open-label, prospective multicenter study%波生坦治疗特发性肺动脉高压患者的疗效及安全性

    Institute of Scientific and Technical Information of China (English)

    代立志; 蒋鑫; 王勇; 余再新; 姚桦; 王广义; 吴炳祥; 荆志成

    2011-01-01

    Objective To investigate the efficacy, safety and tolerance of bosentan, a dual endothelin receptor antagonist, in Chinese patients with idiopathic pulmonary arterial hypertension (IPAH).Methods Totally 79 IPAH patients (hemodynamic criteria confirmed by right heart catheterization) were included in this open-label, prospective multicenter study. Patients received 62. 5 mg of bosentan twice daily for the first 4 weeks, and then up-titrated to 125 mg twice daily for another 12 weeks. The primary end point was the change in exercise capacity showed by six-minute walk distance (6MWD) from baseline to 16 weeks. Secondary end points included the change in World Health Organization (WHO) functional class,Borg dyspnoea scale and systolic pulmonary artery pressure measured by echocardiography. Results The 6MWD increased from (343. 7 ± 93.7) meters at baseline to (397.5 ± 104. 4) meters after 16 weeks ( P <0. 01 ), WHO functional class and Borg dyspnoea scale were also significantly improved after 16 weeks therapy compared to baseline levels (all P <0. 01 ). Furthermore, the systolic pulmonary artery pressure was significantly decreased from (97.8±25.2) mm Hg (1 mm Hg=0. 133 kPa) to (92.8 ±29.5) mm Hg (P <0. 05) after 16 weeks bosentan treatment. There was no patient withdrawal from this study for safety consideration. Conclusion Bosentan therapy is well tolerated and can improve the exercise capacity and WHO functional class in Chinese IPAH patients.%目的 观察内皮素受体拮抗剂波生坦治疗中国特发性肺动脉高压患者的有效性、安全性及耐受性.方法 全国多中心Ⅳ期临床试验,共入选79例右心导管等技术确诊的新发特发性肺动脉高压患者,口服波生坦每日2次,每次62.5 mg,治疗4周后增至每日2次,每次125 mg至16周试验结束.分别在基线及治疗16周时记录6分钟步行距离,WHO肺高压功能分级、Borg呼吸困难评分及超声心动图评价资料.结果 波生坦治疗16

  19. Relativistic Spin Operators

    Institute of Scientific and Technical Information of China (English)

    ZHANG Peng-Fei; RUAN Tu-Nan

    2001-01-01

    A systematic theory on the appropriate spin operators for the relativistic states is developed. For a massive relativistic particle with arbitrary nonzero spin, the spin operator should be replaced with the relativistic one, which is called in this paper as moving spin. Further the concept of moving spin is discussed in the quantum field theory. A new is constructed. It is shown that, in virtue of the two operators, problems in quantum field concerned spin can be neatly settled.

  20. Combination of Rare Right Arterial Variation with Anomalous Origins of the Vertebral Artery, Aberrant Subclavian Artery and Persistent Trigeminal Artery

    Science.gov (United States)

    Ishihara, H.; San Millán Ruíz, D.; Abdo, G.; Asakura, F.; Yilmaz, H.; Lovblad, K.O.; Rüfenacht, D.A.

    2011-01-01

    Summary A 32-year-old woman hospitalized for subarachnoid hemorrhage showed rare arterial variation on the right side with anomalous origins of the vertebral artery, aberrant subclavian artery and persistent trigeminal artery. Angiography showed the right vertebral artery to originate from the right common carotid artery, the right subclavian artery to arise separately from the descending aorta, and persistent trigeminal artery on the right side. The possible embryonic mechanism of this previously unreported variant combination is discussed. PMID:22005696

  1. On Renal Artery Stenosis

    OpenAIRE

    Eklöf, Hampus

    2005-01-01

    Renal artery stenosis (RAS) is a potentially curable cause of hypertension and azotemia. Besides intra-arterial renal angiography there are several non-invasive techniques utilized to diagnose patients with suspicion of renal artery stenosis. Removing the stenosis by revascularization to restore unobstructed blood flow to the kidney is known to improve and even cure hypertension/azotemia, but is associated with a significant complication rate. To visualize renal arteries with x-ray technique...

  2. Vertebral artery aneurysms.

    Directory of Open Access Journals (Sweden)

    Ravi Kumar C

    2000-04-01

    Full Text Available Vertebral artery (VA aneurysms are rare. We present our experience with three cases of VA aneurysms. Two aneurysms were located close to the origin of basilar artery while the third patient had a giant posterior inferior cerebellar artery aneurysm. These aneurysms were operated by the far lateral inferior suboccipital approach with good results.

  3. Retinal artery occlusion

    Science.gov (United States)

    ... artery occlusion; Branch retinal artery occlusion; CRAO; BRAO Images Retina References Sanborn GE, Magargal LE. Arterial obstructive disease ... A.M. Editorial team. Related MedlinePlus Health Topics ... audit to verify that A.D.A.M. follows rigorous standards of quality and accountability. A.D.A.M. is among ...

  4. [Upper extremity arterial diseases].

    Science.gov (United States)

    Becker, F

    2007-02-01

    Compared to lower limb arterial diseases, upper limb arterial diseases look rare, heterogeneous with various etiologies and a rather vague clinical picture, but with a negligible risk of amputation. Almost all types of arterial diseases can be present in the upper limb, but the anatomical and hemodynamic conditions particular to the upper limb often confuse the issue. Thus, atherosclerosis affects mainly the subclavian artery in its proximal segment where the potential of collateral pathway is high making the symptomatic forms not very frequent whereas the prevalence of subclavian artery stenosis or occlusion is relatively high. The clinical examination and the etiologies are discussed according to the clinical, anatomical and hemodynamic context.

  5. Magnetic Nanostructures Spin Dynamics and Spin Transport

    CERN Document Server

    Farle, Michael

    2013-01-01

    Nanomagnetism and spintronics is a rapidly expanding and increasingly important field of research with many applications already on the market and many more to be expected in the near future. This field started in the mid-1980s with the discovery of the GMR effect, recently awarded with the Nobel prize to Albert Fert and Peter Grünberg. The present volume covers the most important and most timely aspects of magnetic heterostructures, including spin torque effects, spin injection, spin transport, spin fluctuations, proximity effects, and electrical control of spin valves. The chapters are written by internationally recognized experts in their respective fields and provide an overview of the latest status.

  6. Labelling Fashion Markets

    OpenAIRE

    Aspers, P.

    2008-01-01

    The present article discusses how an ethical and environmental labelling system can be implemented in fashion garment markets. Consumers act in markets that provide them with more information than their limited cognitive capacity allows them to handle. Ethical and environmental labelling in markets characterized by change, such as the fashion garment market, makes decision-making even more complicated. The ethical and environmental labelling system proposed here is designed to alleviate firms...

  7. Deuterium labeled cannabinoids

    International Nuclear Information System (INIS)

    Complex reactions involving ring opening, ring closure and rearrangements hamper complete understanding of the fragmentation processes in the mass spectrometric fragmentation patterns of cannabinoids. Specifically labelled compounds are very powerful tools for obtaining more insight into fragmentation mechanisms and ion structures and therefore the synthesis of specifically deuterated cannabinoids was undertaken. For this, it was necessary to investigate the preparation of cannabinoids, appropriately functionalized for specific introduction of deuterium atom labels. The results of mass spectrometry with these labelled cannabinoids are described. (Auth.)

  8. Acute occlusion of the left subclavian artery with artery dissection

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ Subclavian steal syndrome is cerebral or brain stem ischemia resulting from diversion of blood flow from the basilar artery to the subclavian artery, which is caused by occlusive disease of either the subclavian artery or the innominate artery before they branch off at the vertebral artery. In the patients with subclavian steal syndrome the subclavian artery is fed by retrograde flow from the vertebral artery via the carotids and the circle of Willis.

  9. RHIC SPIN FLIPPER

    Energy Technology Data Exchange (ETDEWEB)

    BAI,M.; ROSER, T.

    2007-06-25

    This paper proposes a new design of spin flipper for RHIC to obtain full spin flip with the spin tune staying at half integer. The traditional technique of using an rf dipole or solenoid as spin flipper to achieve full spin flip in the presence of full Siberian snake requires one to change the snake configuration to move the spin tune away from half integer. This is not practical for an operational high energy polarized proton collider like RHIC where beam lifetime is sensitive to small betatron tune change. The design of the new spin flipper as well as numerical simulations are presented.

  10. Decoherence dynamics of a single spin versus spin ensemble

    NARCIS (Netherlands)

    Dobrovitski, V.V.; Feiguin, A.E.; Awschalom, D.D.; Hanson, R.

    2008-01-01

    We study decoherence of central spins by a spin bath, focusing on the difference between measurement of a single central spin and measurement of a large number of central spins (as found in typical spin-resonance experiments). For a dilute spin bath, the single spin demonstrates Gaussian free-induct

  11. Topological Spin Hall Effect

    OpenAIRE

    Yin, Gen; Liu, Yizhou; Barlas, Yafis; Zang, Jiadong; Lake, Roger K.

    2015-01-01

    The intrinsic spin Hall effect (SHE) originates from the topology of the Bloch bands in momentum space. The duality between real space and momentum space calls for a spin Hall effect induced from a real space topology in analogy to the topological Hall effect (THE) of skyrmions. We theoretically demonstrate the topological spin Hall effect (TSHE) in which a pure transverse spin current is generated from a skyrmion spin texture.

  12. Intrinsic Spin Hall Effect

    OpenAIRE

    Murakami, Shuichi

    2005-01-01

    A brief review is given on the spin Hall effect, where an external electric field induces a transverse spin current. It has been recognized over 30 years that such effect occurs due to impurities in the presence of spin-orbit coupling. Meanwhile, it was proposed recently that there is also an intrinsic contribution for this effect. We explain the mechanism for this intrinsic spin Hall effect. We also discuss recent experimental observations of the spin Hall effect.

  13. Spin Seebeck Power Conversion

    OpenAIRE

    Cahaya, Adam B.; Tretiakov, Oleg A.; Bauer, G. E. W.

    2015-01-01

    Spin caloritronics is the science and technology to control spin, charge, and heat currents in magnetic nanostructures. The spin degree of freedom provides new strategies for thermolelectric power generation that have not yet been fully explored. After an elementary introduction into conventional thermoelectrics and spintronics, we give a brief review of the physics of spin caloritronics. We discuss spin-dependent thermoelectrics based on the the two-current model in metallic magnets as well ...

  14. Spin projection chromatography

    OpenAIRE

    Danieli, Ernesto P.; Pastawski, Horacio M.; Levstein, Patricia R.

    2003-01-01

    We formulate the many-body spin dynamics at high temperature within the non-equilibrium Keldysh formalism. For the simplest XY interaction, analytical expressions in terms of the one particle solutions are obtained for linear and ring configurations. For small rings of even spin number, the group velocities of excitations depend on the parity of the total spin projection. This should enable a dynamical filtering of spin projections with a given parity i.e. a Spin projection chromatography.

  15. Spin projection chromatography

    Science.gov (United States)

    Danieli, E. P.; Pastawski, H. M.; Levstein, P. R.

    2004-01-01

    We formulate the many-body spin dynamics at high temperature within the non-equilibrium Keldysh formalism. For the simplest XY interaction, analytical expressions in terms of the one particle solutions are obtained for linear and ring configurations. For small rings of even spin number, the group velocities of excitations depend on the parity of the total spin projection. This should enable a dynamical filtering of spin projections with a given parity i.e., a spin projection chromatography.

  16. Hybrid Spin Noise Spectroscopy and the Spin Hall Effect

    OpenAIRE

    Slipko, V. A.; Sinitsyn, N. A.; Pershin, Y. V.

    2013-01-01

    Here we suggest a novel hybrid spin noise spectroscopy technique, which is sensitive to the spin Hall effect. It is shown that, while the standard spin-spin correlation function is not sensitive to the spin Hall effect, spin-transverse voltage and transverse voltage-voltage correlation functions provide the missing sensitivity being linear and quadratic in the spin Hall coefficient, respectively. The correlation between transverse voltage and spin fluctuations appears as a result of spin-char...

  17. Magnons, Spin Current and Spin Seebeck Effect

    Science.gov (United States)

    Maekawa, Sadamichi

    2012-02-01

    When metals and semiconductors are placed in a temperature gradient, the electric voltage is generated. This mechanism to convert heat into electricity, the so-called Seebeck effect, has attracted much attention recently as the mechanism for utilizing wasted heat energy. [1]. Ferromagnetic insulators are good conductors of spin current, i.e., the flow of electron spins [2]. When they are placed in a temperature gradient, generated are magnons, spin current and the spin voltage [3], i.e., spin accumulation. Once the spin voltage is converted into the electric voltage by inverse spin Hall effect in attached metal films such as Pt, the electric voltage is obtained from heat energy [4-5]. This is called the spin Seebeck effect. Here, we present the linear-response theory of spin Seebeck effect based on the fluctuation-dissipation theorem [6-8] and discuss a variety of the devices. [4pt] [1] S. Maekawa et al, Physics of Transition Metal Oxides (Springer, 2004). [0pt] [2] S. Maekawa: Nature Materials 8, 777 (2009). [0pt] [3] Concept in Spin Electronics, eds. S. Maekawa (Oxford University Press, 2006). [0pt] [4] K. Uchida et al., Nature 455, 778 (2008). [0pt] [5] K. Uchida et al., Nature Materials 9, 894 (2010) [0pt] [6] H. Adachi et al., APL 97, 252506 (2010) and Phys. Rev. B 83, 094410 (2011). [0pt] [7] J. Ohe et al., Phys. Rev. B (2011) [0pt] [8] K. Uchida et al., Appl. Phys. Lett. 97, 104419 (2010).

  18. Spin-polarized spin excitation spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Loth, Sebastian; Lutz, Christopher P; Heinrich, Andreas J, E-mail: lothseb@us.ibm.com, E-mail: heinrich@almaden.ibm.com [IBM Research Division, Almaden Research Center, San Jose, CA 95120 (United States)

    2010-12-15

    We report on the spin dependence of elastic and inelastic electron tunneling through transition metal atoms. Mn, Fe and Cu atoms were deposited onto a monolayer of Cu{sub 2}N on Cu(100) and individually addressed with the probe tip of a scanning tunneling microscope. Electrons tunneling between the tip and the substrate exchange energy and spin angular momentum with the surface-bound magnetic atoms. The conservation of energy during the tunneling process results in a distinct onset threshold voltage above which the tunneling electrons create spin excitations in the Mn and Fe atoms. Here we show that the additional conservation of spin angular momentum leads to different cross-sections for spin excitations depending on the relative alignment of the surface spin and the spin of the tunneling electron. For this purpose, we developed a technique for measuring the same local spin with a spin-polarized and a non-spin-polarized tip by exchanging the last apex atom of the probe tip between different transition metal atoms. We derive a quantitative model describing the observed excitation cross-sections on the basis of an exchange scattering process.

  19. Entangled spins and ghost-spins

    CERN Document Server

    Jatkar, Dileep P

    2016-01-01

    We study patterns of quantum entanglement in systems of spins and ghost-spins regarding them as simple quantum mechanical toy models for theories containing negative norm states. We define a single ghost-spin as in arXiv:1602.06505 [hep-th] as a 2-state spin variable with an indefinite inner product in the state space. We find that whenever the spin sector is disentangled from the ghost-spin sector (both of which could be entangled within themselves), the reduced density matrix obtained by tracing over all the ghost-spins gives rise to positive entanglement entropy for positive norm states, while negative norm states have an entanglement entropy with a negative real part and a constant imaginary part. However when the spins are entangled with the ghost-spins, there are new entanglement patterns in general. For systems where the number of ghost-spins is even, it is possible to find subsectors of the Hilbert space where positive norm states always lead to positive entanglement entropy after tracing over the gho...

  20. Bilateral accessory thoracodorsal artery.

    Science.gov (United States)

    Natsis, Konstantinos; Totlis, Trifon; Tsikaras, Prokopios; Skandalakis, Panagiotis

    2006-09-01

    The subscapular artery arises from the third part of the axillary artery and gives off the circumflex scapular and the thoracodorsal arteries. Although anatomical variations of the axillary artery are very common, the existence of a unilateral accessory thoracodorsal artery has been described in the literature only once. There are no reports of bilateral accessory thoracodorsal artery, in the literature. In the present study, a bilateral accessory thoracodorsal artery, originating on either side of the third part of the axillary artery, is described in a 68-year-old female cadaver. All the other branches of the axillary artery had a typical origin, course, distribution and termination. This extremely rare anatomical variation apart from the anatomical importance also has clinical significance for surgeons in this area. Especially, during the dissection or mobilization of the latissimus dorsi that is partly used for coverage problems in many regions of the body and also in dynamic cardiomyoplasty, any iatrogenic injury of this accessory artery may result in ischemia and functional loss of the graft.

  1. Stable isotopes labelled compounds

    International Nuclear Information System (INIS)

    The catalogue on stable isotopes labelled compounds offers deuterium, nitrogen-15, and multiply labelled compounds. It includes: (1) conditions of sale and delivery, (2) the application of stable isotopes, (3) technical information, (4) product specifications, and (5) the complete delivery programme

  2. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    Percutaneous transluminal angioplasty - peripheral artery - discharge; PTA - peripheral artery - discharge; Angioplasty - peripheral artery - discharge; Balloon angioplasty - peripheral artery- discharge; PAD - PTA ...

  3. Label Fusion Strategy Selection

    Directory of Open Access Journals (Sweden)

    Nicolas Robitaille

    2012-01-01

    Full Text Available Label fusion is used in medical image segmentation to combine several different labels of the same entity into a single discrete label, potentially more accurate, with respect to the exact, sought segmentation, than the best input element. Using simulated data, we compared three existing label fusion techniques—STAPLE, Voting, and Shape-Based Averaging (SBA—and observed that none could be considered superior depending on the dissimilarity between the input elements. We thus developed an empirical, hybrid technique called SVS, which selects the most appropriate technique to apply based on this dissimilarity. We evaluated the label fusion strategies on two- and three-dimensional simulated data and showed that SVS is superior to any of the three existing methods examined. On real data, we used SVS to perform fusions of 10 segmentations of the hippocampus and amygdala in 78 subjects from the ICBM dataset. SVS selected SBA in almost all cases, which was the most appropriate method overall.

  4. Automatic classification of retinal vessels into arteries and veins

    Science.gov (United States)

    Niemeijer, Meindert; van Ginneken, Bram; Abràmoff, Michael D.

    2009-02-01

    Separating the retinal vascular tree into arteries and veins is important for quantifying vessel changes that preferentially affect either the veins or the arteries. For example the ratio of arterial to venous diameter, the retinal a/v ratio, is well established to be predictive of stroke and other cardiovascular events in adults, as well as the staging of retinopathy of prematurity in premature infants. This work presents a supervised, automatic method that can determine whether a vessel is an artery or a vein based on intensity and derivative information. After thinning of the vessel segmentation, vessel crossing and bifurcation points are removed leaving a set of vessel segments containing centerline pixels. A set of features is extracted from each centerline pixel and using these each is assigned a soft label indicating the likelihood that it is part of a vein. As all centerline pixels in a connected segment should be the same type we average the soft labels and assign this average label to each centerline pixel in the segment. We train and test the algorithm using the data (40 color fundus photographs) from the DRIVE database1 with an enhanced reference standard. In the enhanced reference standard a fellowship trained retinal specialist (MDA) labeled all vessels for which it was possible to visually determine whether it was a vein or an artery. After applying the proposed method to the 20 images of the DRIVE test set we obtained an area under the receiver operator characteristic (ROC) curve of 0.88 for correctly assigning centerline pixels to either the vein or artery classes.

  5. Radioiodine and its labelled compounds

    International Nuclear Information System (INIS)

    Chemical characteristics and their nuclear characteristics, types of labelled molecules,labelling procedures, direct labelling with various oxidizing agents, indirect labelling with various conjugates attached to protein molecules, purification and quality control. Iodination damage.Safe handling of labelling procedures with iodine radioisotopes.Bibliography

  6. Quantum spin model fitting the Yule distribution of oligonucleotides in DNA

    CERN Document Server

    Minichini, C

    2004-01-01

    A quantum spin chain is identified by the labels of a vector state of a Kashiwara crystal basis. The intensity of the one-spin flip is assumed to depend from the variation of the labels. The rank ordered plot of the numerically computed, averaged in time, transition probabilities is nicely fitted by a Yule distribution, which is the observed distribution of the ranked short oligonucleotides frequency in DNA.

  7. Noncommutativity due to spin

    CERN Document Server

    Gomes, M; da Silva, A J

    2010-01-01

    Using the Berezin-Marinov pseudoclassical formulation of spin particle we propose a classical model of spin noncommutativity. In the nonrelativistic case, the Poisson brackets between the coordinates are proportional to the spin angular momentum. The quantization of the model leads to the noncommutativity with mixed spacial and spin degrees of freedom. A modified Pauli equation, describing a spin half particle in an external e.m. field is obtained. We show that nonlocality caused by the spin noncommutativity depends on the spin of the particle; for spin zero, nonlocality does not appear, for spin half, $\\Delta x\\Delta y\\geq\\theta^{2}/2$, etc. In the relativistic case the noncommutative Dirac equation was derived. For that we introduce a new star product. The advantage of our model is that in spite of the presence of noncommutativity and nonlocality, it is Lorentz invariant. Also, in the quasiclassical approximation it gives noncommutativity with a nilpotent parameter.

  8. Noncommutativity due to spin

    Science.gov (United States)

    Gomes, M.; Kupriyanov, V. G.; da Silva, A. J.

    2010-04-01

    Using the Berezin-Marinov pseudoclassical formulation of the spin particle we propose a classical model of spin noncommutativity. In the nonrelativistic case, the Poisson brackets between the coordinates are proportional to the spin angular momentum. The quantization of the model leads to the noncommutativity with mixed spatial and spin degrees of freedom. A modified Pauli equation, describing a spin half particle in an external electromagnetic field is obtained. We show that nonlocality caused by the spin noncommutativity depends on the spin of the particle; for spin zero, nonlocality does not appear, for spin half, ΔxΔy≥θ2/2, etc. In the relativistic case the noncommutative Dirac equation was derived. For that we introduce a new star product. The advantage of our model is that in spite of the presence of noncommutativity and nonlocality, it is Lorentz invariant. Also, in the quasiclassical approximation it gives noncommutativity with a nilpotent parameter.

  9. Noncommutativity due to spin

    International Nuclear Information System (INIS)

    Using the Berezin-Marinov pseudoclassical formulation of the spin particle we propose a classical model of spin noncommutativity. In the nonrelativistic case, the Poisson brackets between the coordinates are proportional to the spin angular momentum. The quantization of the model leads to the noncommutativity with mixed spatial and spin degrees of freedom. A modified Pauli equation, describing a spin half particle in an external electromagnetic field is obtained. We show that nonlocality caused by the spin noncommutativity depends on the spin of the particle; for spin zero, nonlocality does not appear, for spin half, ΔxΔy≥θ2/2, etc. In the relativistic case the noncommutative Dirac equation was derived. For that we introduce a new star product. The advantage of our model is that in spite of the presence of noncommutativity and nonlocality, it is Lorentz invariant. Also, in the quasiclassical approximation it gives noncommutativity with a nilpotent parameter.

  10. Spin Rotation of Formalism for Spin Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Luccio,A.

    2008-02-01

    The problem of which coefficients are adequate to correctly represent the spin rotation in vector spin tracking for polarized proton and deuteron beams in synchrotrons is here re-examined in the light of recent discussions. The main aim of this note is to show where some previous erroneous results originated and how to code spin rotation in a tracking code. Some analysis of a recent experiment is presented that confirm the correctness of the assumptions.

  11. Popliteal artery entrapment syndrome.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2010-01-01

    Popliteal artery entrapment syndrome is a rare abnormality of the anatomical relationship between the popliteal artery and adjacent muscles or fibrous bands in the popliteal fossa. The following is a case report of a 19 year old female, in whom popliteal artery entrapment syndrome was diagnosed, and successfully treated surgically. A review of literature is also presented and provides details on how PAES is classified, diagnosed both clinically and radiologically, and treated surgically.

  12. [Popliteal artery entrapment syndrome].

    Science.gov (United States)

    Musumeci, S; Iuppa, A; Beneventano, G; Rinella, P; Mammano, M; Cinquegrani, E

    1986-12-15

    Trapped popliteal artery syndrome is relatively uncommon: the literature reports some 60 cases. The clinical picture is linked to compression of the popliteal artery by the gastrocnemius as it contracts, thus distorting the arterial route. The result is an interruption in the blood flow distally to the area involved due to stenosis of the blood vessel that is at first functional but becomes organic. PMID:3808379

  13. Celiac Artery Compression Syndrome

    Directory of Open Access Journals (Sweden)

    Mohammed Muqeetadnan

    2013-01-01

    Full Text Available Celiac artery compression syndrome is a rare disorder characterized by episodic abdominal pain and weight loss. It is the result of external compression of celiac artery by the median arcuate ligament. We present a case of celiac artery compression syndrome in a 57-year-old male with severe postprandial abdominal pain and 30-pound weight loss. The patient eventually responded well to surgical division of the median arcuate ligament by laparoscopy.

  14. Heritability of cilioretinal arteries

    DEFF Research Database (Denmark)

    Taarnhøj, Nina Charlotte; Munch, Inger C; Kyvik, Kirsten O;

    2005-01-01

    of healthy monozygotic and dizygotic twins were examined using digital fundus photography and visual assessment of grayscale fundus photographs and color transparencies to detect the presence of cilioretinal arteries. RESULTS: Cilioretinal arteries were present in 45.1% of participants and 28.8% of eyes....... The majority of cilioretinal arteries, 88.2%, were located temporally, and 11.8% were located nasally. Monozygotic twins had higher concordance rates for cilioretinal arteries than dizygotic twins. Tetrachoric correlations and Mantel-Haenszel odds ratios demonstrated statistically significant evidence...

  15. Peripheral artery disease - legs

    Science.gov (United States)

    ... if they have a history of: Abnormal cholesterol Diabetes Heart disease (coronary artery disease) High blood pressure ( hypertension ) Kidney disease involving hemodialysis Smoking Stroke ( cerebrovascular disease )

  16. Right Coronary Artery Arising from Circumflex Artery: A Case of Single Coronary Artery Anomaly

    Directory of Open Access Journals (Sweden)

    Hekim Karapınar

    2013-08-01

    Full Text Available Coronary artery anomalies could be cause of conflicts for catheterization, especially, in the setting of acute coronary syndrome. We described a case of rare single coronary anomaly which the right coronary artery arisen from terminal part of left circumflex artery. Patient was presented with non-ST segment elevation myocardial infarction. Coronary angiography revealed subtotal stenosis of left anterior descending artery at the mid portion. Left circumflex artery lying in usual route and branch out the posterior descending artery. The right coronary artery arisen from terminal circumflex artery. Left anterior descending artery lesion was stented without any complication.

  17. Nutrition Facts: Reading the Label

    Science.gov (United States)

    ... My Go4Life Get Free Stuff Be a Partner Nutrition Facts: Reading the Label Reading labels can help ... of information on their labels or packaging about nutrition and food safety. Product dates . You might see ...

  18. Hemorheological abnormalities in human arterial hypertension

    Science.gov (United States)

    Lo Presti, Rosalia; Hopps, Eugenia; Caimi, Gregorio

    2014-05-01

    Blood rheology is impaired in hypertensive patients. The alteration involves blood and plasma viscosity, and the erythrocyte behaviour is often abnormal. The hemorheological pattern appears to be related to some pathophysiological mechanisms of hypertension and to organ damage, in particular left ventricular hypertrophy and myocardial ischemia. Abnormalities have been observed in erythrocyte membrane fluidity, explored by fluorescence spectroscopy and electron spin resonance. This may be relevant for red cell flow in microvessels and oxygen delivery to tissues. Although blood viscosity is not a direct target of antihypertensive therapy, the rheological properties of blood play a role in the pathophysiology of arterial hypertension and its vascular complications.

  19. From Label to Practice

    DEFF Research Database (Denmark)

    Byrkjeflot, Haldor; Strandgaard, Jesper; Svejenova, Silviya

    2013-01-01

    This article examines the process of creation of new Nordic cuisine (NNC) as a culinary innovation, focusing on the main stages, actors, and mechanisms that shaped the new label and its practices and facilitated its diffusion in the region and internationally. Fast-paced diffusion was possible...... because NNC was conceived as an identity movement, triggered by active involvement of entrepreneurial leaders from the culinary profession, high-profile political supporters, legitimating scientists, disseminating media, and interpreting audiences. It was facilitated by three mechanisms: First, the use...... actors and institutions to develop practices associated with the NNC label. Third, organized dissemination allowed the excitement and engagement with the new label to spread quickly....

  20. Artery Agenesis: Ipsilateral Common Carotid Artery Hypoplasia

    Directory of Open Access Journals (Sweden)

    Omer Kaya

    2014-01-01

    Full Text Available A 42-year-old female patient, who had been diagnosed with an occlusion of her left internal carotid artery (ICA following Doppler ultrasonographic (US and digitally-subtracted angiographic (DSA examinations performed in an outer healthcare center in order to eliminate the underlying cause of her complaint of amorosis fugax, later applied to our hospital with the same complaint. At Doppler US performed in our hospital’s radiology department, her right common carotid artery (CCA was normal, but her left CCA was hypoplastic. The right internal artery (ICA was validated as normal. At the left side, however, the ICA was apparent only as a stump and it did not demonstrate a continuity. The diagnosis of ICA agenesis was confirmed by the utilization of Doppler US, CT, and DSA imaging, and it was concluded also that ipsilateral CCA hypoplasia could be evaluated as an important clue to the diagnosis of ICA agenesis.

  1. Spin Transport by Collective Spin Excitations

    Science.gov (United States)

    Hammel, P. Chris

    We report studies of angular momentum transport in insulating materials. Our measurements reveal efficient spin pumping from high wavevector k spin waves in thin film Y3Fe5O12 (YIG): spin pumping is independent of wavevector up to k ~ 20 μm-1. Optical detection of YIG FMR by NV centers in diamond reveals a role for spin waves in this insulator-to-insulator spin transfer process. Spin transport is typically suppressed by insulating barriers, but we find that fluctuating antiferromagnetic correlations enable efficient spin transport at nm-scale thicknesses in insulating antiferromagnets, even in the absence of long-range order, and that the spin decay length increases with the strength of the antiferromagnetic correlations. This research is supported by the U.S. DOE through Grants DE-FG02-03ER46054 and DE-SC0001304, by the NSF MRSEC program through Grant No. 1420451 and by the Army Research Office through Grant W911NF0910147.

  2. Clinical applications of cells labelling

    International Nuclear Information System (INIS)

    Blood cells labelled with radionuclides are reviewed and main applications are described. Red blood cell labelling by both random and specific principle. A table with most important clinical uses, 99mTc labelling of RBC are described pre tinning and in vivo reduction of Tc, in vitro labelling and administration of labelled RBC and in vivo modified technique. Labelled leucocytes with several 99mTc-complex radiopharmaceuticals by in vitro technique and specific monoclonal s for white cells(neutrofiles). Labelled platelets for clinical use and research by in vitro technique and in vivo labelling

  3. Arbitrary Spin Galilean Oscillator

    CERN Document Server

    Hagen, C R

    2014-01-01

    The so-called Dirac oscillator was proposed as a modification of the free Dirac equation which reproduces many of the properties of the simple harmonic oscillator but accompanied by a strong spin-orbit coupling term. It has yet to be extended successfully to the arbitrary spin S case primarily because of the unwieldiness of general spin Lorentz invariant wave equations. It is shown here using the formalism of totally symmetric multispinors that the Dirac oscillator can, however, be made to accommodate spin by incorporating it into the framework of Galilean relativity. This is done explicitly for spin zero and spin one as special cases of the arbitrary spin result. For the general case it is shown that the coefficient of the spin-orbit term has a 1/S behavior by techniques which are virtually identical to those employed in the derivation of the g-factor carried out over four decades ago.

  4. Diagnosis of Intracranial Artery Dissection

    Science.gov (United States)

    KANOTO, Masafumi; HOSOYA, Takaaki

    2016-01-01

    Cerebral arterial dissection is defined as a hematoma in the wall of a cervical or an intracranial artery. Cerebral arterial dissection causes arterial stenosis, occlusion, and aneurysm, resulting in acute infarction and hemorrhage. Image analysis by such methods as conventional angiography, computed tomography, magnetic resonance imaging, and so on plays an important role in diagnosing cerebral arterial dissection. In this study, we explore the methods and findings involved in the diagnosis of cerebral arterial dissection. PMID:27180630

  5. Like your labels?

    Science.gov (United States)

    Field, Michele

    2010-01-01

    The descriptive “conventions” used on food labels are always evolving. Today, however, the changes are so complicated (partly driven by legislation requiring disclosures about environmental impacts, health issues, and geographical provenance) that these labels more often baffle buyers than enlighten them. In a light-handed manner, the article points to how sometimes reading label language can be like deciphering runes—and how if we are familiar with the technical terms, we can find a literal meaning, but still not see the implications. The article could be ten times longer because food labels vary according to cultures—but all food-exporting cultures now take advantage of our short attention-span when faced with these texts. The question is whether less is more—and if so, in this contest for our attention, what “contestant” is voted off. PMID:21539053

  6. Succesful labelling schemes

    DEFF Research Database (Denmark)

    Juhl, Hans Jørn; Stacey, Julia

    2001-01-01

    labelling schemes. Mass communication such as TV commercials will have very different impact on each of the four segments. It might be possible to increase the knowledge of 'the labelling blind' from 52% to 75%, but the use of the label would only rise from 16% to 18%. The awareness percentage of 'the...... to carry out a campaign targeted at this segment. The awareness percentage is already 92 % and 67% of the respondents believe they know the meaning of the scheme. But it stands to reason to study whether the respondents actually know what the labelling scheme stands for or if they just think they do....... If there is discrepancy between their perceptions of the contents of the schemes, this might be the reason why the scheme is not observed when they shop....

  7. Behind the Label "Alcoholic."

    Science.gov (United States)

    Wright, Deborah M.

    1989-01-01

    Relates individual's personal story of her childhood influenced by her parent's alcoholism, her own alcoholism as a young adult, and her experiences with counseling. Asks others not to reject her because of the label "alcoholic." (ABL)

  8. FDA Online Label Repository

    Data.gov (United States)

    U.S. Department of Health & Human Services — The drug labels and other drug-specific information on this Web site represent the most recent drug listing information companies have submitted to the Food and...

  9. Spin Hall Effect

    OpenAIRE

    Schliemann, John

    2006-01-01

    It is proposed that when a charge current circulates in a paramagnetic metal a transverse spin imbalance will be generated, giving rise to a 'spin Hall voltage'. Similarly, that when a spin current circulates a transverse charge imbalance will be generated, hence a Hall voltage, in the absence of charge current and magnetic field. Based on these principles we propose an experiment to generate and detect a spin current in a paramagnetic metal.

  10. A Beautiful Spin

    International Nuclear Information System (INIS)

    Spin is a beautiful concept that plays an ever important role in modern physics. In this talk, I start with a discussion of the origin of spin, and then turn to three themes in which spin has been crucial in subatomic physics: a lab to explore physics beyond the standard model, a tool to measure physical observables that are hard to obtain otherwise, a probe to unravel nonperturbative QCD. I conclude with some remarks on a world without spin

  11. Splanchnic artery aneurysms

    Directory of Open Access Journals (Sweden)

    Davidović Lazar B.

    2006-01-01

    Full Text Available Introduction. Splanchnic artery aneurysms are uncommon but important vascular entity because nearly 25% of all cases present as surgical emergency. Objective. The purpose of our study was to present nine patients operated on at the Institute of cardiovascular diseases, as well as literature review of clinical presentation of the disease. Method. There were three splenic artery aneurysms, two celiac trunk aneurysms, and one aneurysm of the hepatic, superior mesenteric, inferior mesenteric and gastroduodenal artery. All patients were males, mean aged 67.5 years (60-73. In four patients, splanchnic artery aneurysm was discovered accidentally during routine ultrasonographic and angiographic examinations of the abdominal aorta. At that time, arteriovenous fistula was diagnosed in a patient No 1; it was formed after rupture of the splenic artery aneurysm into the splenic vein. Three aneurysms were manifested by abdominal pain and palpable pulsating abdominal mass. Two patients were admitted as urgent cases in the state of hemorrhagic shock and signs of intraabdominal bleeding due to rupture of the splenic and hepatic arteries. In 7 cases, diagnosis was made preoperatively by means of ultrasonography and angiography; in two patients, accurate diagnosis was confirmed during surgery. Results. Proximal and distal ligation of the artery was performed in a patient with rupture of the splenic aneurysm into the splenic vein that caused arteriovenous fistula. Gastroduodenal artery aneurysm was treated by trans-aneurysmatic ligation of its "entering" and "exiting" branches. Aneurysms of distal part of the superior mesenteric and splenic artery were resected without further reconstruction. Partial resection of the aneurysm and endoaneurysmorrhaphy was carried out in one case of celiac trunk aneurysm, and in another, after aneurysm resection, the restoration of blood flow through the hepatic and lienal artery was achieved by Dacron grafts. In a patient with the

  12. Certified Rule Labeling

    OpenAIRE

    Nagele, Julian; Zankl, Harald

    2015-01-01

    The rule labeling heuristic aims to establish confluence of (left-)linear term rewrite systems via decreasing diagrams. We present a formalization of a confluence criterion based on the interplay of relative termination and the rule labeling in the theorem prover Isabelle. Moreover, we report on the integration of this result into the certifier CeTA, facilitating the checking of confluence certificates based on decreasing diagrams for the first time. The power of the method is illustrated by ...

  13. Artery by Neuropeptides

    Directory of Open Access Journals (Sweden)

    Esmeralda Sofia Costa Delgado

    2012-01-01

    Methods. Isolated rabbit eyes (n=12 were perfused in situ with tyrode through the external ophthalmic artery. Effects of intra-arterial injections of NPY 200 μg/ml (Group A; n=6 and VIP 200 μg/ml (Group B; n=6 on the recorded pressure were obtained. For statistical analysis, Student's paired t-test and Fast Fourier Transform were used. Results. Spontaneous oscillations were observed before any drug administration in the 12 rabbit models. NPY produced an increase in total vascular resistance and a higher frequency and amplitude of oscillations, while VIP evoked the opposite effects. Conclusions. This study provides evidence of vasomotion in basal conditions in rabbit external ophthalmic artery. Concerning drug effects, NPY increased arterial resistance and enhanced vasomotion while VIP produced opposite effects which demonstrates their profound influence in arterial vasomotion.

  14. [Transposition of Great Artery].

    Science.gov (United States)

    Konuma, Takeshi; Shimpo, Hideto

    2015-07-01

    Transposition of the great artery is one of common congenital cardiac disease resulting cyanosis. Death occurs easily in untreated patients with transposition and intact ventricular septal defect (VSD) in infancy at a few days of age when posterior descending coronary artery (PDA) closed. Since there are 2 parallel circulations, flow from pulmonary to systemic circulation is necessary for systemic oxygenation, and Balloon atrial septostomy or prostaglandin infusion should be performed especially if patient do not have VSD. Although the advent of fetal echocardiography, it is difficult to diagnose the transposition of the great arteries (TGA) as abnormality of great vessels is relatively undistinguishable. The diagnosis of transposition is in itself an indication for surgery, and arterial switch procedure is performed in the case the left ventricle pressure remains more than 2/3 of systemic pressure. Preoperative diagnosis is important as associated anomalies and coronary artery branching patterns are important to decide the operative indication and timing of surgery.

  15. Spinning Eggs and Ballerinas

    Science.gov (United States)

    Cross, Rod

    2013-01-01

    Measurements are presented on the rise of a spinning egg. It was found that the spin, the angular momentum and the kinetic energy all decrease as the egg rises, unlike the case of a ballerina who can increase her spin and kinetic energy by reducing her moment of inertia. The observed effects can be explained, in part, in terms of rolling friction…

  16. The Beauty of Spin

    OpenAIRE

    Meißner, Ulf-G.

    2010-01-01

    I review recent developments in theoretical spin physics. Topics include pion production in nucleon-nucleon collisions, the implications of heavy quark spin symmetry for heavy hadron molecules, the nucleon electric dipole form factors and ab initio calculations of the width of hadron resonances. A few spin physics high-lights from experiments at the COSY accelerator are also discussed.

  17. Spin-torque transistor

    NARCIS (Netherlands)

    Bauer, G.E.W.; Brataas, A.; Tserkovnyak, Y.; Van Wees, B.J.

    2003-01-01

    A magnetoelectronic thin-film transistor is proposed that can display negative differential resistance and gain. The working principle is the modulation of the soure–drain current in a spin valve by the magnetization of a third electrode, which is rotated by the spin-torque created by a control spin

  18. Labelling of electricity

    International Nuclear Information System (INIS)

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) presents a possible course of action to be taken to provide a means of declaring the sources of electrical power, as is foreseen in the draft of new Swiss electricity market legislation. The report presents the basic ideas behind the idea and defines the terms used such as labelling, certificates and declarations. Also, the legal situation in the European Union and in Switzerland is examined and a quantitative overview of electricity production and consumption is presented. Suggestions for a labelling scheme are made and some of the problems to be expected are looked at. The report also presents a series of examples of labelling schemes already implemented in other countries, such as Austria, Great Britain, Sweden and Germany. Tradable certificates and tracking systems are discussed as are initial quality labels like the Swiss 'Naturemade' label for green power. A concrete recommendation for the declaration and labelling of electricity in Switzerland is presented and various factors to be considered such as import/export, pumped storage, distribution losses, small-scale producers as well as the time-scales for introduction are discussed

  19. Folosirea spectrometrului RES ART-6 IFIN in studii cu markeri de spin

    International Nuclear Information System (INIS)

    Characteristics of the ESR spectrometer ART-6, made at the Institute of Phzsics and Nuclear Engineering (IFIN), Magurele-Bucharest (sensitivity 3x1011 spin/G, resolving power 100 mG, magnetic field stability 2x1q-5, frequency stability 2x10-6) are presented along with the instrumental parameters used in the study of spin labels, 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO) and 3-methylene-5-(piperinide-N-methyl)-4-oxo-2,2,6,6-tetramethylpiperidine-1oxyl. These spin labels were used for the investigation of some biological membranes. 40 ref. (authors)

  20. Off-Label Drug Use

    Science.gov (United States)

    ... Your Local Offices Close + - Text Size Off-label Drug Use What is off-label drug use? In the United States new drugs are ... unapproved use of a drug. Is off-label drug use legal? The off-label use of FDA- ...

  1. Genetic algorithms for map labeling

    NARCIS (Netherlands)

    Dijk, Steven Ferdinand van

    2002-01-01

    Map labeling is the cartographic problem of placing the names of features (for example cities or rivers) on the map. A good labeling has no intersections between labels. Even basic versions of the problem are NP-hard. In addition, realistic map-labeling problems deal with many cartographic constr

  2. European consumers and nutrition labelling

    DEFF Research Database (Denmark)

    Wills, Josephine M.; Grunert, Klaus G.; Celemín, Laura Fernández;

    2009-01-01

    Nutrition labelling of food in Europe is not compulsory, unless a nutrition or health claim is made for the product. The European Commission is proposing mandatory nutrition labelling, even front of pack labelling with nutrition information. Yet, how widespread is nutrition labelling in the EU...

  3. Inverse spin Hall effect by spin injection

    Science.gov (United States)

    Liu, S. Y.; Horing, Norman J. M.; Lei, X. L.

    2007-09-01

    Motivated by a recent experiment [S. O. Valenzuela and M. Tinkham, Nature (London) 442, 176 (2006)], the authors present a quantitative microscopic theory to investigate the inverse spin-Hall effect with spin injection into aluminum considering both intrinsic and extrinsic spin-orbit couplings using the orthogonalized-plane-wave method. Their theoretical results are in good agreement with the experimental data. It is also clear that the magnitude of the anomalous Hall resistivity is mainly due to contributions from extrinsic skew scattering.

  4. Spin supplementary conditions for spinning compact binaries

    CERN Document Server

    Mikóczi, Balázs

    2016-01-01

    We consider the different spin supplementary conditions (SSC) for a spinning compact binary with the leading-order spin-orbit (SO) interaction. The Lagrangian of the binary system can be constructed but it is acceleration-dependent in two cases of SSC. We rewrite the generalized Hamiltonian formalism proposed by Ostrogradsky and compute the conservative quantities and the dissipative part of relative motion during the gravitational radiation of each SSCs. We give the orbital elements and observed quantities of the SO dynamics, for instance the energy and the orbital angular momentum losses and waveforms and discuss their SSC dependence.

  5. Off label use of devices and drugs in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zvavanjanja, R.C., E-mail: Rodrick.Zvavanjanja@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool (United Kingdom); Odetoyinbo, T.O.; Rowlands, P.C.; Healey, A.; Abdelsalam, H.; Powell, S.; Evans, J.C.; Hughes, M.L.; Gould, D.A.; McWilliams, R.G. [Royal Liverpool University Hospital, Liverpool (United Kingdom)

    2012-03-15

    Aim: To establish how often off-label device and drug use occurs in interventional radiology (IR) in a UK tertiary referral hospital and consider the wider implications for the interventional radiologist. Materials and methods: Prospective data were collected during interventional procedures for 1 working week in a university hospital. Out-of-hours procedures and procedures outside the department were excluded. Operators were asked to record the drugs and devices used, the indication, and method of use. The instructions for use/summary of product characteristics were then studied for each device/drug used to assess if the use was on or off-label. Results: During the study period 52 cases were performed and data were available on 26 cases (50%). In 22 of the 26 cases (84%) there was evidence of off-label use of devices or drugs. Off-label use of drugs included treatment of venous malformations with Fibrovein{sup Copyright-Sign} (sodium tetradecyl sulphate), which is licensed for the treatment of varicose veins in the leg, and intra-arterial injection of heparin, which is licensed for intravenous and subcutaneous use. Off-label device use included placing vascular sheaths in the urinary tract, using angiographic catheters to guide wires in the urinary tract, using sheaths for thrombosuction, reshaping of the tip of most guidewires, and using angioplasty balloons to dislodge the arterial plug at fistula thrombectomy. Conclusion: Off-label device and drugs use is common in a UK tertiary hospital IR department and literature suggests this is common in the wider IR community. There are important clinical and legal implications for off-label use for patients and physicians.

  6. MR imaging of the arterial wall in normal volunteers and arteriosclerotic patients

    International Nuclear Information System (INIS)

    MR angiography is based on the signal characteristics of flowing blood, whereas the arterial wall is not delineated. Its visualization requires maximal spatial resolution and reliable compensation for moving spins. Presaturation and rephasing gradients were applied to spin-echo and fast low-angle shot (FLASH) sequences combined with a reduction of the field of view to approximately 10 cm. Three-dimensional FLASH sequences demonstrated spin saturation within the imaging volume without additional radio-frequency pulses and was sensitive to alterations in the arterial wall. CHESS techniques (fat sensitive) suppressed signal from the normal arterial wall. Small fatty or sclerotic deposits in the femoral, popliteal, and carotid walls were detected prior to marked stenosis

  7. Kagome spin ice

    Science.gov (United States)

    Mellado, Paula

    Spin ice in magnetic pyrochlore oxides is a peculiar magnetic state. Like ordinary water ice, these materials are in apparent violation with the third law of thermodynamics, which dictates that the entropy of a system in thermal equilibrium vanishes as its temperature approaches absolute zero. In ice, a "zero-point" entropy is retained down to low temperatures thanks to a high number of low-energy positions of hydrogen ions associated with the Bernal-Fowler ice-rules. Spins in pyrochlore oxides Ho2Ti 2O7 and Dy2Ti2O7 exhibit a similar degeneracy of ground states and thus also have a sizable zero-point entropy. A recent discovery of excitations carrying magnetic charges in pyrochlore spin ice adds another interesting dimension to these magnets. This thesis is devoted to a theoretical study of a two-dimensional version of spin ice whose spins reside on kagome, a lattice of corner-sharing triangles. It covers two aspects of this frustrated classical spin system: the dynamics of artificial spin ice in a network of magnetic nanowires and the thermodynamics of crystalline spin ice. Magnetization dynamics in artificial spin ice is mediated by the emission, propagation and absorption of domain walls in magnetic nanowires. The dynamics shows signs of self-organized behavior such as avalanches. The theoretical model compares favorably to recent experiments. The thermodynamics of the microscopic version of spin ice on kagome is examined through analytical calculations and numerical simulations. The results show that, in addition to the high-temperature paramagnetic phase and the low-temperature phase with magnetic order, spin ice on kagome may have an intermediate phase with fluctuating spins and ordered magnetic charges. This work is concluded with a calculation of the entropy of kagome spin ice at zero temperature when one of the sublattices is pinned by an applied magnetic field and the system breaks up into independent spin chains, a case of dimensional reduction.

  8. Coronary Artery Bypass

    Directory of Open Access Journals (Sweden)

    Kadri Ceberut

    2011-01-01

    Full Text Available Ancient schwannoma is a rare variant of neural tumors though rarely seen in the thorax. The combination with coronary artery diseases is also rare. Here we describe a 66 year-old male who had undergone one-stage combined surgery for thoracic ancient schwannomas removal and coronary artery disease. The masses were, respectively, 13 cm in the middle mediastinum and 5 cm in diameter originating from the intercostal nerve. The tumors were successfully removed using sternotomy, and then a coronary artery bypass grafting was performed. Here we discuss this rare tumor in relation to the relevant literature.

  9. Radioactive labelling of peptidic hormones

    International Nuclear Information System (INIS)

    The labelling of peptidic hormones requires stability, specificity and sensitivity of the label. Introduction of a radioactive atome is one way to satisfy these criteria. Several processes have been described to prepare radioactive TRF: synthesis of the peptide with labelled aminoacids or introduction of the label into the hormone. In that approach, tritium can be substituted in the imidazole ring, via precursors activating the proper carbon. Monoiodo TRF leads essentially to tritium labelling of the 5 positions whereas monoazo TRF allows the preparation of 3H TRF labelled in the 2 positions. Di-substituted TRF leads to labelling into the 2 and 5 carbons. Labelled analogs of TRF can be prepared with labelled iodine; further developments of peptide labelling, will be presented. In particular, the homolytic scission of the C-iodine, bond by photochemical activation. The nascent carbon radical can be stabilized by a tritiated scavenger. This approach eliminates the use of heavy metal catalysts

  10. Indium-111-labeled platelet scintigraphy in carotid atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Minar, E.; Ehringer, H.; Dudczak, R.; Schoefl, R.J.; Jung, M.; Koppensteiner, R.; Ahmadi, R.; Kretschmer, G.

    1989-01-01

    We evaluated platelet accumulation in carotid arteries by means of a dual-radiotracer method, using indium-111-labeled platelets and technetium-99m-labeled human serum albumin, in 123 patients (92 men, 31 women; median age 60 years). Sixty patients had symptoms of transient ischemic carotid artery disease, and 63 patients with peripheral arterial occlusive disease served as controls. Antiplatelet treatment with acetylsalicylic acid was taken by 53 of the 123 patients. In 36 of the 60 symptomatic patients, platelet scintigraphy was repeated 3-4 days after carotid endarterectomy. Comparison of different scintigraphic parameters (platelet accumulation index and percent of the injected dose of labeled platelets at the carotid bifurcation) showed no significant differences between symptomatic and asymptomatic patients, and the severity of stenosis and the presence of plaque ulceration also had no influence on the parameters. There was no difference between patients with a short (less than 4 weeks) or long (greater than 4 weeks) interval from the last transient ischemic attack to scintigraphy and no difference between patients with or without antiplatelet treatment. Classifying the patients according to plaque morphology judged by high-resolution real-time ultrasonography also demonstrated no differences. No significant correlation was found between any scintigraphic parameter and other platelet function parameters such as platelet survival time, platelet turnover rate, and concentration of platelet-specific proteins. Quantification of platelet deposition after carotid endarterectomy in 36 patients demonstrated a significant increase of the median platelet accumulation index and the percent injected dose index.

  11. Muon spin relaxation in random spin systems

    International Nuclear Information System (INIS)

    The longitudinal relaxation function Gsub(z)(t) of the positive muon can reflect dynamical characters of local field in a unique way even when the correlation time is longer than the Larmor period of local field. This method has been applied to studies of spin dynamics in spin glass systems, revealing sharp but continuous temperature dependence of the correlation time. Its principle and applications are reviewed. (author)

  12. Synthesis of labeled compounds

    International Nuclear Information System (INIS)

    Intermediate compounds labeled with 13C included methane, sodium cyanide, methanol, ethanol, and acetonitrile. A new method for synthesizing 15N-labeled 4-ethylsulfonyl-1-naphthalene-sulfonamide was developed. Studies were conducted on pathways to oleic-1-13C acid and a second pathway investigated was based on carbonation of 8-heptadecynylmagnesium bromide with CO2 to prepare sterolic acid. Biosynthetic preparations included glucose-13C from starch isolated from tobacco leaves following photosynthetic incubation with 13CO2 and galactose-13C from galactosylglycerol-13C from kelp. Research on growth of organisms emphasized photosynthetic growth of algae in which all cellular carbon is labeled. Preliminary experiments were performed to optimize the growth of Escherichia coli on sodium acetate-13C

  13. Coronary artery spasm

    Science.gov (United States)

    ... blocker or a long-acting nitrate long-term. Beta-blockers are another type of medicine that is used with other coronary artery problems. However, beta-blockers may make this problem worse. They should be ...

  14. Peripheral Arterial Disease

    Science.gov (United States)

    Peripheral arterial disease (PAD) happens when there is a narrowing of the blood vessels outside of your heart. The cause of ... smoking. Other risk factors include older age and diseases like diabetes, high blood cholesterol, high blood pressure, ...

  15. Pulmonary Arterial Hypertension

    Science.gov (United States)

    Pulmonary Arterial Hypertension What Is Pulmonary Hypertension? To understand pulmonary hypertension (PH) it helps to understand how blood ows throughout your body. While the heart is one organ, it ...

  16. Renal arteries (image)

    Science.gov (United States)

    A renal angiogram is a test used to examine the blood vessels of the kidneys. The test is performed ... main vessel of the pelvis, up to the renal artery that leads into the kidney. Contrast medium ...

  17. Coronary Artery Bypass Surgery

    Science.gov (United States)

    ... don't help, you may need coronary artery bypass surgery. The surgery creates a new path for ... narrowed area or blockage. This allows blood to bypass (get around) the blockage. Sometimes people need more ...

  18. Semantic Role Labeling

    CERN Document Server

    Palmer, Martha; Xue, Nianwen

    2011-01-01

    This book is aimed at providing an overview of several aspects of semantic role labeling. Chapter 1 begins with linguistic background on the definition of semantic roles and the controversies surrounding them. Chapter 2 describes how the theories have led to structured lexicons such as FrameNet, VerbNet and the PropBank Frame Files that in turn provide the basis for large scale semantic annotation of corpora. This data has facilitated the development of automatic semantic role labeling systems based on supervised machine learning techniques. Chapter 3 presents the general principles of applyin

  19. Spin accumulation in the extrinsic spin Hall effect

    Science.gov (United States)

    Tse, Wang-Kong; Fabian, J.; Žutić, I.; Das Sarma, S.

    2005-12-01

    The drift-diffusion formalism for spin-polarized carrier transport in semiconductors is generalized to include spin-orbit coupling. The theory is applied to treat the extrinsic spin Hall effect using realistic boundary conditions. It is shown that carrier and spin-diffusion lengths are modified by the presence of spin-orbit coupling and that spin accumulation due to the extrinsic spin Hall effect is strongly and qualitatively influenced by boundary conditions. Analytical formulas for the spin-dependent carrier recombination rates and inhomogeneous spin densities and currents are presented.

  20. Spin caloritronics in graphene

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Angsula; Frota, H. O. [Department of Physics, Federal University of Amazonas, Av. Rodrigo Octavio 3000-Japiim, 69077-000 Manaus, AM (Brazil)

    2015-06-14

    Spin caloritronics, the combination of spintronics with thermoelectrics, exploiting both the intrinsic spin of the electron and its associated magnetic moment in addition to its fundamental electronic charge and temperature, is an emerging technology mainly in the development of low-power-consumption technology. In this work, we study the thermoelectric properties of a Rashba dot attached to two single layer/bilayer graphene sheets as leads. The temperature difference on the two graphene leads induces a spin current, which depends on the temperature and chemical potential. We demonstrate that the Rashba dot behaves as a spin filter for selected values of the chemical potential and is able to filter electrons by their spin orientation. The spin thermopower has also been studied where the effects of the chemical potential, temperature, and also the Rashba term have been observed.

  1. Coronary anomaly: the single coronary artery

    Institute of Scientific and Technical Information of China (English)

    QIN Xu-guang; XIONG Wei-guo; LU Chun-peng; GONG Cheng-jie; SHANG Li-hua

    2010-01-01

    @@ Single coronary artery (SCA), defined as an artery that arises from the arterial trunk and nourishes the entire myocardium, is rare. We report two cases of SCA, one is the right coronary artery (RCA) originating from the middle of left descending artery (LAD), and the other is the left main coronary artery (LMCA) arising from the proximal right coronary artery.

  2. Nuclear spin noise imaging

    OpenAIRE

    Müller, Norbert; Jerschow, Alexej

    2006-01-01

    NMR images were obtained from the proton spin noise signals of a water-containing phantom, which was placed in the highly tuned, low-noise resonant circuit of a cryogenically cooled NMR probe in the presence of systematically varied magnetic field gradients. The spatially resolved proton spin density was obtained from the raw signal by a modified projection–reconstruction protocol. Although spin noise imaging is inherently less sensitive than conventional magnetic resonance imaging, it afford...

  3. Nonequilibrium spin noise spectroscopy

    OpenAIRE

    Li, Fuxiang; Pershin, Yuriy V.; Slipko, Valeriy A.; Sinitsyn, Nikolai A.

    2013-01-01

    Spin Noise Spectroscopy (SNS) is an experimental approach to obtain correlators of mesoscopic spin fluctuations in time by purely optical means. We explore the information that this technique can provide when it is applied to a weakly non-equilibrium regime when an electric current is driven through a sample by an electric field. We find that the noise power spectrum of conducting electrons experiences a shift, which is proportional to the strength of the spin-orbit coupling for electrons mov...

  4. Spin Hall noise

    OpenAIRE

    Kamra, A.; Witek, F.P.; Meyer, S.; Huebl, H.; Geprägs, S.; Gross, R.; Bauer, G. E. W.; Goennenwein, S. T. B.

    2014-01-01

    We measure the low-frequency thermal fluctuations of pure spin current in a Platinum film deposited on yttrium iron garnet via the inverse spin Hall effect (ISHE)-mediated voltage noise as a function of the angle $\\alpha$ between the magnetization and the transport direction. The results are consistent with the fluctuation dissipation theorem in terms of the recently discovered spin Hall magnetoresistance (SMR). We present a microscopic description of the $\\alpha$ dependence of the voltage no...

  5. Spin coating apparatus

    Science.gov (United States)

    Torczynski, John R.

    2000-01-01

    A spin coating apparatus requires less cleanroom air flow than prior spin coating apparatus to minimize cleanroom contamination. A shaped exhaust duct from the spin coater maintains process quality while requiring reduced cleanroom air flow. The exhaust duct can decrease in cross section as it extends from the wafer, minimizing eddy formation. The exhaust duct can conform to entrainment streamlines to minimize eddy formation and reduce interprocess contamination at minimal cleanroom air flow rates.

  6. Multi-label

    Directory of Open Access Journals (Sweden)

    Neda Abdelhamid

    2015-01-01

    Full Text Available Generating multi-label rules in associative classification (AC from single label data sets is considered a challenging task making the number of existing algorithms for this task rare. Current AC algorithms produce only the largest frequency class connected with a rule in the training data set and discard all other classes even though these classes have data representation with the rule’s body. In this paper, we deal with the above problem by proposing an AC algorithm called Enhanced Multi-label Classifiers based Associative Classification (eMCAC. This algorithm discovers rules associated with a set of classes from single label data that other current AC algorithms are unable to induce. Furthermore, eMCAC minimises the number of extracted rules using a classifier building method. The proposed algorithm has been tested on a real world application data set related to website phishing and the results reveal that eMCAC’s accuracy is highly competitive if contrasted with other known AC and classic classification algorithms in data mining. Lastly, the experimental results show that our algorithm is able to derive new rules from the phishing data sets that end-users can exploit in decision making.

  7. Labeling of herbicide femesafen

    International Nuclear Information System (INIS)

    5-[2-chroo-4-(trifluoromethyl ) phenoxy]-N-(methyl sulphonyl )-2-niorobenzamide [femesafen] was labeled by six steps. Radio-chemical yield was 19.15%. TLC analysis of the final product showed that the radiochemical purity is not less than 99%. (authors)

  8. Waisda?: video labeling game

    NARCIS (Netherlands)

    Hildebrand, M.; Brinkerink, M.; Gligorov, R.; Steenbergen, M. van; Huijkman, J.; Oomen, J.

    2013-01-01

    The Waisda? video labeling game is a crowsourcing tool to collect user-generated metadata for video clips. It follows the paradigm of games-with-a-purpose, where two or more users play against each other by entering tags that describe the content of the video. Players score points by entering the sa

  9. Genetic algorithms for map labeling

    OpenAIRE

    Dijk, Steven Ferdinand van

    2002-01-01

    Map labeling is the cartographic problem of placing the names of features (for example cities or rivers) on the map. A good labeling has no intersections between labels. Even basic versions of the problem are NP-hard. In addition, realistic map-labeling problems deal with many cartographic constraints, which pose more demands on how the labels should be placed in relation to their surroundings. For example, a label is preferably placed above and to the right of a city. These two aspects (comb...

  10. Straintronic spin-neuron

    OpenAIRE

    Biswas, Ayan K.; Atulasimha, Jayasimha; Bandyopadhyay, Supriyo

    2015-01-01

    In artificial neural networks, neurons are usually implemented with highly dissipative CMOS-based operational amplifiers. A more energy-efficient implementation is a 'spin-neuron' realized with a magneto-tunneling junction (MTJ) that is switched with a spin-polarized current (representing weighted sum of input currents) that either delivers a spin transfer torque or induces domain wall motion in the soft layer of the MTJ. Here, we propose and analyze a different type of spin-neuron in which t...

  11. A quantum spin-probe molecular microscope

    Science.gov (United States)

    Perunicic, V. S.; Hill, C. D.; Hall, L. T.; Hollenberg, L.C.L.

    2016-01-01

    Imaging the atomic structure of a single biomolecule is an important challenge in the physical biosciences. Whilst existing techniques all rely on averaging over large ensembles of molecules, the single-molecule realm remains unsolved. Here we present a protocol for 3D magnetic resonance imaging of a single molecule using a quantum spin probe acting simultaneously as the magnetic resonance sensor and source of magnetic field gradient. Signals corresponding to specific regions of the molecule's nuclear spin density are encoded on the quantum state of the probe, which is used to produce a 3D image of the molecular structure. Quantum simulations of the protocol applied to the rapamycin molecule (C51H79NO13) show that the hydrogen and carbon substructure can be imaged at the angstrom level using current spin-probe technology. With prospects for scaling to large molecules and/or fast dynamic conformation mapping using spin labels, this method provides a realistic pathway for single-molecule microscopy. PMID:27725630

  12. An artery-specific fluorescent dye for studying neurovascular coupling

    OpenAIRE

    Shen, Zhiming; Lu, Zhongyang; Chhatbar, Pratik Y.; O’Herron, Philip; Kara, Prakash

    2012-01-01

    We demonstrate that Alexa Fluor 633 hydrazide (Alexa Fluor 633) selectively labels neocortical arteries and arterioles by binding to elastin fibers. We measured sensory stimulus–evoked arteriole dilation dynamics in mouse, rat and cat visual cortex using Alexa Fluor 633 together with neuronal activity using calcium indicators or blood flow using fluorescein dextran. Arteriole dilation decreased fluorescence recorded from immediately underlying neurons, representing a potential artifact during...

  13. Probing spin-charge separation using spin transport

    OpenAIRE

    Si, Qimiao

    2000-01-01

    Pedagogical discussions are given on what constitutes a signature of spin-charge separation. A proposal is outlined to probe spin-charge separation in the normal state of the high $T_c$ cuprates using spin transport. Specifically, the proposal is to compare the temperature dependences of the spin resistivity and electrical resistivity: Spin-charge separation will be manifested in the different temperature dependences of these two resistivities. We also estimate the spin diffusion length and s...

  14. Response of a spin valve to a spin battery

    OpenAIRE

    Pham, Khuôn-Viêt

    2016-01-01

    It is shown that spin valves under suitable symmetry conditions exhibit an ON-OFF response to a spin battery, and are therefore perfect spin transistors. While a spin valve driven by a charge battery displays the usual GMR (Giant Magneto-Resistance), this means that a pure spin current or pure spin accumulation can generate an infinite magnetoresistance (IMR). Magnetic tunnel junctions as well as CPP (current perpendicular to plane) or CIP (current in plane) metallic trilayers are discussed.

  15. Quantum theory of spin waves in finite chiral spin chains

    OpenAIRE

    Roldán-Molina, A.; Santander, M. J.; Núñez, A.S.; Fernández Rossier, Joaquín

    2013-01-01

    We calculate the effect of spin waves on the properties of finite-size spin chains with a chiral spin ground state observed on biatomic Fe chains deposited on iridium(001). The system is described with a Heisenberg model supplemented with a Dzyaloshinskii-Moriya coupling and a uniaxial single ion anisotropy that presents a chiral spin ground state. Spin waves are studied using the Holstein-Primakoff boson representation of spin operators. Both the renormalized ground state and the elementary ...

  16. [Splenic artery aneurysms].

    Science.gov (United States)

    Colović, R; Davidović, L; Bilanović, D; Krivokapić, Z; Grubor, N; Cvetković, S; Radak, V; Marković, M

    2006-01-01

    Although the third most frequent aneurysm in the abdomen, after aneurysms of the aorta and iliac arteries, and most frequent aneurisms of visceral arteries, splenic artery aneurysms are rare, but not very rare. Thanks to the new imaging techniques, first of all ultrasonography, they have been discovered with increasing frequency. We present a series of 9 splenic artery aneurysms. Seven patients were female and two male of average age 49 years (ranging from 28 to 75 years). The majority of afected women were multiparae, with average 3 children (ranging from 1 to 6). One patient had a subacute rupture, and 2 had ruptures into the splenic vein causing portal hypertension. The spleen was enlarged in 7 out of 9 patients. The average size of aneurysms was 3,2 cm (ranging from 2 to 8 cm). The preoperative diagnosis of splenic artery aneurysm was established in 6 patients while in 3 patients aneurism was accidentally found during other operations, during splenectomy in 2, and during the excision of a retroperitoneal tumour in 1 patient. Aneurysmectomy was carried out in 7 patients, while a ligation of the incoming and outcoming wessels was performed in 2 patients with arteriovenous fistula. Splenectomy was performed in 6 patients, while pancreatic tail resection, cholecystectomy and excision of the retroperitoneal tumor were performed in 3 patients. Additional resection of the abdominal aortic aneurysm with reconstruction of aortoiliac segment was performed in 2 patients. There were no mortality and the postoperative recovery was uneventful in all patients. PMID:16989145

  17. BILATERAL DUPLICATION OF RENAL ARTERIES

    Directory of Open Access Journals (Sweden)

    Prajkta A Thete

    2014-09-01

    Full Text Available Routine dissection of a male cadaver revealed the presence of bilateral double renal arteries. On the right side the accessory renal artery originated from the abdominal aorta just above the main renal artery. On the left side the accessory renal artery originated from the abdominal aorta about 1 cm above the main renal artery. Knowledge of the variations of renal vascular anatomy has importance in exploration and treatment of renal trauma, renal transplantation, renal artery embolization, surgery for abdominal aortic aneurysm and conservative or radical renal surgery

  18. Use the Nutrition Facts Label

    Science.gov (United States)

    ... Features Spokespeople News Archive eNewsletters Calendar Use the Nutrition Facts Label You can help your family eat ... to some of their favorite foods. Use the Nutrition Facts label found on food packages to make ...

  19. Anomalous right coronary artery arising from left anterior descending artery

    Directory of Open Access Journals (Sweden)

    M.L. Sreenivas Kumar

    2012-07-01

    Full Text Available A 54-year-old male patient presented with acute myocardial infarction involving left anterior descending and right coronary artery territories. Coronary angiogram showed a single coronary artery with right coronary artery arising from left anterior descending artery (LAD, which coursed anterior to right ventricular outflow tract and thrombotic lesion in mid left anterior descending artery before origin of right coronary artery. The patient was treated with thrombolytic therapy and glycoprotein IIb/IIIa inhibitors. Anomalous origin of right coronary artery as a branch of LAD is a very rare type of congenital coronary artery anomalies. It is important to recognize this anomaly as it can be associated with extensive myocardial ischemia and sudden cardiac death in young persons even without atherosclerosis.

  20. Antiferromagnetic spin Seebeck effect.

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Stephen M.; Zhang, Wei; KC, Amit; Borisov, Pavel; Pearson, John E.; Jiang, J. Samuel; Lederman, David; Hoffmann, Axel; Bhattacharya, Anand

    2016-03-03

    We report on the observation of the spin Seebeck effect in antiferromagnetic MnF2. A device scale on-chip heater is deposited on a bilayer of MnF2 (110) (30nm)/Pt (4 nm) grown by molecular beam epitaxy on a MgF2(110) substrate. Using Pt as a spin detector layer, it is possible to measure the thermally generated spin current from MnF2 through the inverse spin Hall effect. The low temperature (2–80 K) and high magnetic field (up to 140 kOe) regime is explored. A clear spin-flop transition corresponding to the sudden rotation of antiferromagnetic spins out of the easy axis is observed in the spin Seebeck signal when large magnetic fields (>9T) are applied parallel to the easy axis of the MnF2 thin film. When the magnetic field is applied perpendicular to the easy axis, the spin-flop transition is absent, as expected.

  1. Spin Hall noise

    NARCIS (Netherlands)

    Kamra, A.; Witek, F.P.; Meyer, S.; Huebl, H.; Geprägs, S.; Gross, R.; Bauer, G.E.W.; Goennenwein, S.T.B.

    2014-01-01

    We measure the low-frequency thermal fluctuations of pure spin current in a platinum film deposited on yttrium iron garnet via the inverse spin Hall effect (ISHE)-mediated voltage noise as a function of the angle α between the magnetization and the transport direction. The results are consistent wit

  2. Spin stripes in nanotubes

    OpenAIRE

    Kleiner, Alex

    2002-01-01

    It is shown here that electrons on the surface of a nanotube in a perpendicular magnetic field undergo spin-chirality separation along the circumference. Stripes of spin-polarization propagate along the tube, with a spatial pattern that can be modulated by the electron filling.

  3. Single spin magnetic resonance

    Science.gov (United States)

    Wrachtrup, Jörg; Finkler, Amit

    2016-08-01

    Different approaches have improved the sensitivity of either electron or nuclear magnetic resonance to the single spin level. For optical detection it has essentially become routine to observe a single electron spin or nuclear spin. Typically, the systems in use are carefully designed to allow for single spin detection and manipulation, and of those systems, diamond spin defects rank very high, being so robust that they can be addressed, read out and coherently controlled even under ambient conditions and in a versatile set of nanostructures. This renders them as a new type of sensor, which has been shown to detect single electron and nuclear spins among other quantities like force, pressure and temperature. Adapting pulse sequences from classic NMR and EPR, and combined with high resolution optical microscopy, proximity to the target sample and nanoscale size, the diamond sensors have the potential to constitute a new class of magnetic resonance detectors with single spin sensitivity. As diamond sensors can be operated under ambient conditions, they offer potential application across a multitude of disciplines. Here we review the different existing techniques for magnetic resonance, with a focus on diamond defect spin sensors, showing their potential as versatile sensors for ultra-sensitive magnetic resonance with nanoscale spatial resolution.

  4. Spin torque transistor revisited

    NARCIS (Netherlands)

    Chiba, T.; Bauer, G.E.W.; Takahashi, S.

    2013-01-01

    We theoretically study the operation of a 4-terminal device consisting of two lateral thin-film spin valves that are coupled by a magnetic insulator such as yttrium iron garnet via the spin transfer torque. By magnetoelectronic circuit theory we calculate the current voltage characteristics and find

  5. Arterial hypertension and cancer.

    Science.gov (United States)

    Milan, Alberto; Puglisi, Elisabetta; Ferrari, Laura; Bruno, Giulia; Losano, Isabel; Veglio, Franco

    2014-05-15

    Arterial hypertension and cancer are two of the most important causes of mortality in the world; correlations between these two clinical entities are complex and various. Cancer therapy using old (e.g., mitotic spindle poisons) as well as new (e.g., monoclonal antibody) drugs may cause arterial hypertension through different mechanisms; sometimes the increase of blood pressure levels may be responsible for chemotherapy withdrawal. Among newer cancer therapies, drugs interacting with the VEGF (vascular endothelial growth factors) pathways are the most frequently involved in hypertension development. However, many retrospective studies have suggested a relationship between antihypertensive treatment and risk of cancer, raising vast public concern. The purposes of this brief review have then been to analyse the role of chemotherapy in the pathogenesis of hypertension, to summarize the general rules of arterial hypertension management in this field and finally to evaluate the effects of antihypertensive therapy on cancer disease.

  6. Labelling GM-free Products

    DEFF Research Database (Denmark)

    Punt, Maarten; Venus, Thomas; Wesseler, Justus

    2016-01-01

    Food suppliers in the EU must comply with labelling regulations for genetically modified organisms (GMOs). However, excluded from mandatory labelling are food products derived from animals fed with GM feed (mainly GM soybean in the EU). Because of this labelling exemption, consumers are unable to...

  7. Food Labels Tell the Story!

    Science.gov (United States)

    ... My World From the Label to the Table! Food Labels Tell the Story! What is in food? Food provides your body with all of the ... your food choices. Nutrition Facts—the Labels on Food Products Beginning in 1994, the US government began ...

  8. Spin Waves in Terbium

    DEFF Research Database (Denmark)

    Jensen, J.; Houmann, Jens Christian Gylden; Bjerrum Møller, Hans

    1975-01-01

    The energies of spin waves propagating in the c direction of Tb have been studied by inelastic neutron scattering, as a function of a magnetic field applied along the easy and hard directions in the basal plane, and as a function of temperature. From a general spin Hamiltonian, consistent...... with the symmetry, we deduce the dispersion relation for the spin waves in a basal-plane ferromagnet. This phenomenological spin-wave theory accounts for the observed behavior of the magnon energies in Tb. The two q⃗-dependent Bogoliubov components of the magnon energies are derived from the experimental results...... with increasing temperatures implies that the two-ion coupling is effectively isotropic above ∼ 150 K. We present arguments for concluding that, among the mechanisms which may introduce anisotropic two-ion couplings in the rare-earth metals, the modification of the indirect exchange interaction by the spin...

  9. Spin-Wave Diode

    Science.gov (United States)

    Lan, Jin; Yu, Weichao; Wu, Ruqian; Xiao, Jiang

    2015-10-01

    A diode, a device allowing unidirectional signal transmission, is a fundamental element of logic structures, and it lies at the heart of modern information systems. The spin wave or magnon, representing a collective quasiparticle excitation of the magnetic order in magnetic materials, is a promising candidate for an information carrier for the next-generation energy-saving technologies. Here, we propose a scalable and reprogrammable pure spin-wave logic hardware architecture using domain walls and surface anisotropy stripes as waveguides on a single magnetic wafer. We demonstrate theoretically the design principle of the simplest logic component, a spin-wave diode, utilizing the chiral bound states in a magnetic domain wall with a Dzyaloshinskii-Moriya interaction, and confirm its performance through micromagnetic simulations. Our findings open a new vista for realizing different types of pure spin-wave logic components and finally achieving an energy-efficient and hardware-reprogrammable spin-wave computer.

  10. Combined arterial and venous whole-body MR angiography with cardiac MR imaging in patients with thromboembolic disease - initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, Florian M.; Hunold, Peter; Barkhausen, Joerg [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Herborn, Christoph U. [University Hospital Hamburg-Eppendorf, Medical Prevention Center Hamburg (MPCH) at University Hospital Hamburg-Eppendorf, Hamburg (Germany); Ruehm, Stefan G. [David Geffen School of Medicine at UCLA, Department of Radiology, Los Angeles, CA (United States); Kroger, Knut [University Hospital Essen, Department of Angiology, Essen (Germany)

    2008-05-15

    The objective was to assess the feasibility of a combined arterial and venous whole-body three-dimensional magnetic resonance (MR) angiography, together with a cardiac MR examination, in patients with arterial thromboembolism. Ten patients with arterial thromboembolism underwent a contrast-enhanced whole-body MR examination of the arterial and venous vessels, followed by a cardiac MR examination on a separate occasion within 24 h. All examinations were performed on a 1.5-T MR scanner. For both arterial and venous MR angiography only one injection of contrast agent was necessary. The cardiac imaging protocol included dark-blood-prepared half-Fourier acquisition single-shot turbo-spin-echo sequences, fast steady-state free precession cine sequences, T2-weighted turbo-spin-echo sequences and inversion recovery gradient-echo fast low-angle-shot sequences after injection of contrast agent. MR imaging revealed additional clinically unknown arterial thromboembolisms in four patients. The thoracic aorta was depicted as embolic source in four patients, while deep vein thrombosis (DVT) was found in one patient as the underlying disease. Unsuspected infarction of parenchymal organs was detected by MRI in two patients. An unknown additional DVT was found in one patient. Four patients were considered to have arterial emboli of cardiac origin. In conclusion, acquisition of arterial and venous MR angiograms of the entire vascular system combined with cardiac MR imaging is a most comprehensive and valuable strategy in patients with arterial thromboembolism. (orig.)

  11. Fractionalized spin-wave continuum in kagome spin liquids

    Science.gov (United States)

    Mei, Jia-Wei; Wen, Xiao-Gang

    Motivated by spin-wave continuum (SWC) observed in recent neutron scattering experiments in Herbertsmithite, we use Gutzwiller-projected wave functions to study dynamic spin structure factor S (q , ω) of spin liquid states on the kagome lattice. Spin-1 excited states in spin liquids are represented by Gutzwiller-projected two-spinon excited wave functions. We investigate three different spin liquid candidates, spinon Fermi-surface spin liquid (FSL), Dirac spin liquid (DSL) and random-flux spin liquid (RSL). FSL and RSL have low energy peaks in S (q , ω) at K points in the extended magnetic Brillouin zone, in contrast to experiments where low energy peaks are found at M points. There is no obviuos contradiction between DSL and neutron scattering measurements. Besides a fractionalized spin (i.e. spin-1/2), spinons in DSL carry a fractionalized crystal momentum which is potentially detectable in SWC in the neutron scattering measurements.

  12. Synchronization of spin-transfer torque oscillators by spin pumping, inverse spin Hall, and spin Hall effects

    International Nuclear Information System (INIS)

    We have proposed a method to synchronize multiple spin-transfer torque oscillators based on spin pumping, inverse spin Hall, and spin Hall effects. The proposed oscillator system consists of a series of nano-magnets in junction with a normal metal with high spin-orbit coupling, and an accumulative feedback loop. We conduct simulations to demonstrate the effect of modulated charge currents in the normal metal due to spin pumping from each nano-magnet. We show that the interplay between the spin Hall effect and inverse spin Hall effect results in synchronization of the nano-magnets

  13. Spin Hall and spin Nernst effects in graphene with intrinsic and Rashba spin-orbit interactions

    Institute of Scientific and Technical Information of China (English)

    Zhu Guo-Bao

    2012-01-01

    The spin Hall and spin Nernst effects in graphene are studied based on Green's function formalism.We calculate intrinsic contributions to spin Hall and spin Nernst conductivities in the Kane-Mele model with various structures.When both intrinsic and Rashba spin-orbit interactions are present,their interplay leads to some characteristics of the dependence of spin Hall and spin Nernst conductivities on the Fermi level.When the Rashba spin-orbit interaction is smaller than intrinsic spin-orbit coupling,a weak kink in the conductance appears.The kink disappears and a divergence appears when the Rashba spin-orbit interaction enhances.When the Rashba spin-orbit interaction approaches and is stronger than intrinsic spin-orbit coupling,the divergence becomes more obvious.

  14. Pharmacological modulation of arterial stiffness.

    LENUS (Irish Health Repository)

    Boutouyrie, Pierre

    2011-09-10

    Arterial stiffness has emerged as an important marker of cardiovascular risk in various populations and reflects the cumulative effect of cardiovascular risk factors on large arteries, which in turn is modulated by genetic background. Arterial stiffness is determined by the composition of the arterial wall and the arrangement of these components, and can be studied in humans non-invasively. Age and distending pressure are two major factors influencing large artery stiffness. Change in arterial stiffness with drugs is an important endpoint in clinical trials, although evidence for arterial stiffness as a therapeutic target still needs to be confirmed. Drugs that independently affect arterial stiffness include antihypertensive drugs, mostly blockers of the renin-angiotensin-aldosterone system, hormone replacement therapy and some antidiabetic drugs such as glitazones. While the quest continues for \\'de-stiffening drugs\\

  15. To Spin or Not to Spin?

    Institute of Scientific and Technical Information of China (English)

    Tina Boikos

    2008-01-01

    @@ The alarm has just gone off. Do I really have to get up? I wonder. Originally, signing up for an early-morning spinning class seemed like a good idea; it jump-starts the day with some well-needed exercise.

  16. Gluon Spin Contribution to The Nucleon Spin

    Energy Technology Data Exchange (ETDEWEB)

    Arash, Firooz, E-mail: farash@cic.aut.ac.i [Physics Department, Tafresh University, Tafresh (Iran, Islamic Republic of); Shahveh, Abolfazl [Physics Department, Tafresh University, Tafresh (Iran, Islamic Republic of); Taghavi-Shahri, Fateme [School of Particles and Accelerators, Institute for Research in Fundamental Sciences (IPM) P.O. Box 19395-5531, Tehran (Iran, Islamic Republic of)

    2010-10-15

    We have calculated {delta}g/g in the nucleon at all measured kinematics. The smallness of {delta}g/g in the measured kinematics should not be interpreted as the the gluon contribution to the nucleon spin is small. In fact the first moment of gluon polarization in the nucleon, {Delta}g(Q{sup 2}) can be sizable.

  17. Gluon Spin Contribution to The Nucleon Spin

    Science.gov (United States)

    Arash, Firooz; Shahveh, Abolfazl; Taghavi-Shahri, Fateme

    2010-10-01

    We have calculated δg/ g in the nucleon at all measured kinematics. The smallness of δg/ g in the measured kinematics should not be interpreted as the the gluon contribution to the nucleon spin is small. In fact the first moment of gluon polarization in the nucleon, Δ g( Q2) can be sizable.

  18. Gluon Spin Contribution to The Nucleon Spin

    International Nuclear Information System (INIS)

    We have calculated δg/g in the nucleon at all measured kinematics. The smallness of δg/g in the measured kinematics should not be interpreted as the the gluon contribution to the nucleon spin is small. In fact the first moment of gluon polarization in the nucleon, Δg(Q2) can be sizable.

  19. Combination of rare right arterial variation with anomalous origins of the vertebral artery, aberrant subclavian artery and persistent trigeminal artery. A case report.

    Science.gov (United States)

    Ishihara, H; San Millán Ruíz, D; Abdo, G; Asakura, F; Yilmaz, H; Lovblad, K O; Rüfenacht, D A

    2011-09-01

    A 32-year-old woman hospitalized for subarachnoid hemorrhage showed rare arterial variation on the right side with anomalous origins of the vertebral artery, aberrant subclavian artery and persistent trigeminal artery. Angiography showed the right vertebral artery to originate from the right common carotid artery, the right subclavian artery to arise separately from the descending aorta, and persistent trigeminal artery on the right side. The possible embryonic mechanism of this previously unreported variant combination is discussed. PMID:22005696

  20. Liver cirrhosis and arterial hypertension

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik; Møller, Søren

    2006-01-01

    blood pressure. This review considers the alterations in systemic hemodynamics in patients with cirrhosis in relation to essential hypertension and arterial hypertension of the renal origin. Subjects with arterial hypertension (essential, secondary) may become normotensive during the development...... of cirrhosis, and arterial hypertension is rarely manifested in patients with cirrhosis, even in cases with renovascular disease and high circulating renin activity. There is much dispute as to the understanding of homoeostatic regulation in cirrhotic patients with manifest arterial hypertension. This most...

  1. Pulmonary artery sling: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Gil Hyun; Lee, Sun Wha; Cha, Sung Ho [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    1993-09-15

    Aberrant left-sided pulmonary artery(pulmonary artery sling) is an uncommon anomaly,which may cause significant respiratory abnormality. We report a case of pulmonary artery sling which is combined with persistent left superior vena cava and dextrocardia. This case were identified by esophagogram and CT and confirmed by MRI and angiography. We consider that MRI is a valuable new method for the diagnosis of aberrant left-sided pulmonary artery.

  2. Screening asymptomatic patients with diabetes for unknown coronary artery disease: Does it reduce risk? An open-label randomized trial comparing a strategy based on exercise testing aimed at revascularization with management based on pharmacological/behavioural treatment of traditional risk factors. DADDY-D Trial (Does coronary Atherosclerosis Deserve to be Diagnosed and treated early in Diabetics?

    Directory of Open Access Journals (Sweden)

    Romano Stefania

    2009-12-01

    Full Text Available Abstract Background Coronary artery disease is the leading cause of morbidity and mortality in patients with type 2 diabetes. Screening for asymptomatic coronary artery disease with treatment by means of revascularization seems to be an appealing option for prevention. The utility of such a strategy has never been challenged in a randomized trial. Methods/Design In the present study a cohort of diabetic patients without any symptoms and without known coronary artery disease will be screened at two diabetes outpatients services. Those with intermediate or high risk (equal or greater than 10% according to the Italian risk chart will be asked to participate and enrolled. They will be seen and followed in order to provide the best adherence to medical therapy. Half of the patients will be randomized to undergo an exercise tolerance testing while the other group will continue to be regularly seen at diabetes outpatients services. Best medical/behavioral therapy will be offered to both groups. Those patients with a positive exercise tolerance testing will be studied by coronary angiography and treated according to the severity of coronary lesions by percutaneous stenting or surgery. The objective of the study is to evaluate the efficacy of the screening strategy aimed at revascularization. A cost-effectiveness analysis will be performed at the end of the follow up. Discussion The study will provide useful information about prevention and treatment of diabetic patients at high risk of coronary events. It will be made clearer if detection of silent coronary artery disease has to be recommended and followed by treatment. Given the simplicity of the study protocol, it will be easily transferable to the real world. Trial registration (ClinicalTrials.gov: NCT00547872

  3. Linerless label device and method

    KAUST Repository

    Binladen, Abdulkari

    2016-01-14

    This apparatus and method for applying a linerless label to an end user product includes a device with a printer for printing on a face surface of a linerless label, and a release coat applicator for applying a release coat to the face surface of the label; another device including an unwinder unit (103) to unwind a roll of printed linerless label; a belt (108); a glue applicator (102) for applying glue to the belt; a nip roller (106) for contacting and applying pressure to the face surface of the linerless label such that the glue on the belt transfers to the back surface of the linerless label; at least one slitting knife 105) positioned downstream the belt and a rewinder unit (104) positioned downstream the slitting knife; and a third device which die cuts and applies the linerless label to an end user object.

  4. Indium-111 labelled platelets: experimental and clinical studies

    International Nuclear Information System (INIS)

    The object of the present study became to develop a method of effective and gentle isolation and 111-In labelling of human platelets, as well as to employ these platelets in human clinical studies with the object of elucidating a number of physiological and pathophysiological mechanisms and processes in which platelets take part. 111-In-oxine presents obvious advantages over 51-Cr-sodium chromate; a high labelling efficiency, and more advantageous physical properties (a half life of 68 hours (against the half life of 28 days for 51-Cr) and considerably more effective gamma emission), making external registration by means of a gamma camera possible. Considering the role played by platelets in the development of atherosclerosis and its thromboembolic complications, in the early phases of deep venous thrombosis, and in graft rejection, it is natural that attempts have been made to use 111-In-labelled platelets for scintigraphic and kinetic evaluation of thromboembolic processes. Accumulation of 111-In-labelled platelets at sites of vessel wall injury, on pulmonary emboli (presumably on deep vein thrombi as well), and on catheter material has been demonstrated. Beyond this, the number of publications concerning the use of 111-In-labelled platelets for visualization of atherosclerosis, venous thromboembolism, arterial grafts, intracardiac thrombi, aortic aneurysms, renal allograft rejection, and other situations in which platelet thromboembolism takes place, provides evidence that a tool has finally been found for the study of their nature and response to therapeutic intervention. (eg)

  5. Cardiopulmonary fitness correlates with regional cerebral grey matter perfusion and density in men with coronary artery disease.

    Directory of Open Access Journals (Sweden)

    Bradley J MacIntosh

    Full Text Available PURPOSE: Physical activity is associated with positive effects on the brain but there is a paucity of clinical neuroimaging data in patients with coronary artery disease (CAD, a cardiovascular condition associated with grey matter loss. The purpose of this study was to determine which brain regions are impacted by cardiopulmonary fitness and with the change in fitness after 6 months of exercise-based cardiac rehabilitation. METHODS: CAD patients underwent magnetic resonance imaging at baseline, and peak volume of oxygen uptake during exercise testing (VO2Peak was measured at baseline and after 6 months of training. T1-weighted structural images were used to perform grey matter (GM voxel-based morphometry (VBM. Pseudo-continuous arterial spin labeling (pcASL was used to produce cerebral blood flow (CBF images. VBM and CBF data were tested voxel-wise using VO2Peak and age as explanatory variables. RESULTS: In 30 men with CAD (mean age 65±7 years, VBM and CBF identified 7 and 5 respective regions positively associated with baseline VO2Peak. These included the pre- and post-central, paracingulate, caudate, hippocampal regions and converging findings in the putamen. VO2Peak increased by 20% at follow-up in 29 patients (t = 9.6, df = 28, p<0.0001. Baseline CBF in the left post-central gyrus and baseline GM density in the right putamen predicted greater change in VO2Peak. CONCLUSION: Perfusion and GM density were associated with fitness at baseline and with greater fitness gains with exercise. This study identifies new neurobiological correlates of fitness and demonstrates the utility of multi-modal MRI to evaluate the effects of exercise in CAD patients.

  6. Popliteal Artery Entrapment Syndrome

    DEFF Research Database (Denmark)

    Altintas, Ümit; Helgstrand, Ulf Johan Vilhelm; Hansen, Marc A;

    2013-01-01

    The purpose of this study was to report our experience with popliteal artery entrapment syndrome (PAES) with special emphasis on the applicability of duplex ultrasound scanning (DUS) when diagnosing PAES. In addition to examining the correlation between DUS and intraoperative findings...

  7. Persistent Trigeminal Artery

    Directory of Open Access Journals (Sweden)

    Dijo T George

    2015-04-01

    Full Text Available Trigeminal artery is the commonest of the four primitive anastomoses between the carotid and vertebrobasilar system that may rarely persist in adults, with an angiographic incidence of 0.1 - 0.6%. We present the CT and MR angiograms of a patient who presented with a minor stroke and was detected to have this anomaly and briefly discuss the significance

  8. Representation of Spin Group Spin(p, q)

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The representation (&)(p, q) of spin group Spin(p, q) in any dimensional space is given by induction, and the relation between two representations, which are obtained in two kinds of inductions from Spin(p, q) to Spin(p + 1, q + 1)are studied.

  9. Electron spin decoherence in nuclear spin baths and dynamical decoupling

    International Nuclear Information System (INIS)

    We introduce the quantum theory of the electron spin decoherence in a nuclear spin bath and the dynamical decoupling approach for protecting the electron spin coherence. These theories are applied to various solid-state systems, such as radical spins in molecular crystals and NV centers in diamond.

  10. Spin drift and spin diffusion currents in semiconductors

    Directory of Open Access Journals (Sweden)

    M Idrish Miah

    2008-01-01

    Full Text Available On the basis of a spin drift-diffusion model, we show how the spin current is composed and find that spin drift and spin diffusion contribute additively to the spin current, where the spin diffusion current decreases with electric field while the spin drift current increases, demonstrating that the extension of the spin diffusion length by a strong field does not result in a significant increase in spin current in semiconductors owing to the competing effect of the electric field on diffusion. We also find that there is a spin drift-diffusion crossover field for a process in which the drift and diffusion contribute equally to the spin current, which suggests a possible method of identifying whether the process for a given electric field is in the spin drift or spin diffusion regime. Spin drift-diffusion crossover fields for GaAs are calculated and are found to be quite small. We derive the relations between intrinsic spin diffusion length and the spin drift-diffusion crossover field of a semiconductor for different electron statistical regimes. The findings resulting from this investigation might be important for semiconductor spintronics.

  11. Quantifying Spin Hall Angles from Spin Pumping: Experiments and Theory

    NARCIS (Netherlands)

    Mosendz, O.; Pearson, J.E.; Fradin, F.Y.; Bauer, G.E.W.; Bader, S.D.; Hoffmann, A.

    2010-01-01

    Spin Hall effects intermix spin and charge currents even in nonmagnetic materials and, therefore, ultimately may allow the use of spin transport without the need for ferromagnets. We show how spin Hall effects can be quantified by integrating Ni80Fe20|normal metal (N) bilayers into a coplanar wavegu

  12. SPIN Tutorial: How to Become a SPIN Doctor

    NARCIS (Netherlands)

    Ruys, T.C.; Bosnacki, D.; Leue, S.

    2002-01-01

    SPIN is a model checker for the verification of software systems. SPIN uses a high level language called PROMELA to specify systems descriptions. The goal of this tutorial is to introduce novice users to both PROMELA and SPIN. The tutorial itself is divided into two parts. The BASIC SPIN part is tar

  13. Label-Guided Graph Exploration with Adjustable Ratio of Labels

    CERN Document Server

    Zhang, Meng; Tang, Jijun

    2012-01-01

    The graph exploration problem is to visit all the nodes of a connected graph by a mobile entity, e.g., a robot. The robot has no a priori knowledge of the topology of the graph or of its size. Cohen et al. \\cite{Ilcinkas08} introduced label guided graph exploration which allows the system designer to add short labels to the graph nodes in a preprocessing stage; these labels can guide the robot in the exploration of the graph. In this paper, we address the problem of adjustable 1-bit label guided graph exploration. We focus on the labeling schemes that not only enable a robot to explore the graph but also allow the system designer to adjust the ratio of the number of different labels. This flexibility is necessary when maintaining different labels may have different costs or when the ratio is pre-specified. We present 1-bit labeling (two colors, namely black and white) schemes for this problem along with a labeling algorithm for generating the required labels. Given an $n$-node graph and a rational number $\\rh...

  14. Fluorescence labeling to study platelet and leucocyte deposition onto vascular grafts in vitro.

    Science.gov (United States)

    Toes, G J; van den Dungen, J J; Haan, J; Hermens, R A; van Oeveren, W

    1999-10-01

    Platelets and leucocytes are important participants in the response of the body to small diameter vascular grafts implanted into the arterial circulation. A sensitive and quick method for measuring platelet and leucocyte deposition contributes to material evaluation. With a newly developed fluorescence labeling method we examined the deposition of platelets and leucocytes onto vascular grafts in vitro. Human platelets and leucocytes were isolated and labeled with the fluorescence label Europium trichloride (EuCl3). After reconstitution of the labeled cells in plasma their functionality appeared intact and competitive with unlabeled cells. Eu-labeled platelets or leucocytes were then incubated with expanded polytetrafluoroethylene (ePTFE), Dacron and polyurethane (PU) vascular grafts in autologous plasma. Beta-thromboglobin and thromboxane release from platelets and beta-glucuronidase release from leucocytes during the incubation experiments were measured. Platelets and leucocytes deposited significantly less onto ePTFE compared to Dacron and polyurethane (P release. PMID:10514073

  15. Spin transfer torque with spin diffusion in magnetic tunnel junctions

    KAUST Repository

    Manchon, Aurelien

    2012-08-09

    Spin transport in magnetic tunnel junctions in the presence of spin diffusion is considered theoretically. Combining ballistic tunneling across the barrier and diffusive transport in the electrodes, we solve the spin dynamics equation in the metallic layers. We show that spin diffusion mixes the transverse spin current components and dramatically modifies the bias dependence of the effective spin transfer torque. This leads to a significant linear bias dependence of the out-of-plane torque, as well as a nonconventional thickness dependence of both spin torque components.

  16. Higher spin cosmology

    Science.gov (United States)

    Krishnan, Chethan; Raju, Avinash; Roy, Shubho; Thakur, Somyadip

    2014-02-01

    We construct cosmological solutions of higher spin gravity in 2+1 dimensional de Sitter space. We show that a consistent thermodynamics can be obtained for their horizons by demanding appropriate holonomy conditions. This is equivalent to demanding the integrability of the Euclidean boundary conformal field theory partition function, and it reduces to Gibbons-Hawking thermodynamics in the spin-2 case. By using the prescription of Maldacena, we relate the thermodynamics of these solutions to those of higher spin black holes in AdS3.

  17. Quantum Spin Hall Effect

    Energy Technology Data Exchange (ETDEWEB)

    Bernevig, B.Andrei; Zhang, Shou-Cheng; /Stanford U., Phys. Dept.

    2010-01-15

    The quantum Hall liquid is a novel state of matter with profound emergent properties such as fractional charge and statistics. Existence of the quantum Hall effect requires breaking of the time reversal symmetry caused by an external magnetic field. In this work, we predict a quantized spin Hall effect in the absence of any magnetic field, where the intrinsic spin Hall conductance is quantized in units of 2 e/4{pi}. The degenerate quantum Landau levels are created by the spin-orbit coupling in conventional semiconductors in the presence of a strain gradient. This new state of matter has many profound correlated properties described by a topological field theory.

  18. Spins in chemistry

    CERN Document Server

    McWeeny, Roy

    2004-01-01

    Originally delivered as a series of lectures, this volume systematically traces the evolution of the ""spin"" concept from its role in quantum mechanics to its assimilation into the field of chemistry. Author Roy McWeeny presents an in-depth illustration of the deductive methods of quantum theory and their application to spins in chemistry, following the path from the earliest concepts to the sophisticated physical methods employed in the investigation of molecular structure and properties. Starting with the origin and development of the spin concept, the text advances to an examination of sp

  19. Frustrated spin systems

    CERN Document Server

    2013-01-01

    This book covers all principal aspects of currently investigated frustrated systems, from exactly solved frustrated models to real experimental frustrated systems, going through renormalization group treatment, Monte Carlo investigation of frustrated classical Ising and vector spin models, low-dimensional systems, spin ice and quantum spin glass. The reader can - within a single book - obtain a global view of the current research development in the field of frustrated systems.This new edition is updated with recent theoretical, numerical and experimental developments in the field of frustrated

  20. Basilar Artery Aneurysm at a Persistent Trigeminal Artery Junction

    Science.gov (United States)

    Aguiar, G.B.; Conti, M.L.M.; Veiga, J.C.E.; Jory, M.; Souza, R.B.

    2011-01-01

    Summary The trigeminal artery is an anastomosis between the embryonic precursors of the vertebrobasilar and carotid systems, and may persist into adult life. The association of the persistent primitive trigeminal artery (PTA) with cerebral aneurysm is well documented in the literature and, in general, aneurysms are located in the anterior circulation. We describe a patient who presented with a panencephalic Fisher III subarachnoid hemorrhage due to rupture of an intracranial aneurysm. Digital arteriography showed a saccular aneurysm in the middle third of the basilar artery, adjacent to the junction with a persistent trigeminal artery. She was submitted to endovascular treatment with embolization of the basilar artery aneurysm with coils. Aneurysms at the PTA junction with the basilar artery are rare. This paper describes a case of PTA associated with an aneurysm in the basilar artery at PTA junction and briefly reviews the literature. PMID:22005697

  1. Labelled compounds. (Pt. B)

    International Nuclear Information System (INIS)

    Since the end of World War II there has been a tremendous increase in the number of compounds that have been synthesized with radioactive or stable isotopes. They have found application in many diverse fields, so much so, that hardly a single area in pure and applied science has not benefited. Not surprisingly it has been reflected in appearance of related publications. The early proceedings of the Symposia on Advances in Trace Methodology were soon followed by various Euratom sponsored meetings in which methods of preparing and storing labelled compounds featured prominently. In due course a resurgence of interest in stable isotopes, brought about by their greater availability (also lower cost) and partly by development of new techniques such as gas chromatography - mass spectrometry (gc-ms), led to the publication of proceedings of several successful conferences. More recently conferences dealing with the synthesis and applications of isotopes and isotopically labelled compounds have been established on a regular basis. In addition to the proceedings of conferences and journal publications individuals left their mark by producing definitive texts, usually on specific nuclides. Only the classic two volume publication of Murray and Williams (Organic syntheses with isotopes, New York 1985), now over 30 years old and out of print, attempted to do justice to several nuclides. With the large amount of work that has been undertaken since then it seems unlikely that an updated edition could be produced. The alternative strategy was to ask scientists currently active to review specific areas and this is the approach adopted in the present series of monographs. In this way it is intended to cover the broad advances that have been made in the synthesis and applications of isotopes and isotopically labelled compounds in the physical and biomedical sciences. (author). refs.; figs.; tabs

  2. Waisda?: video labeling game

    OpenAIRE

    Hildebrand, Michiel; Brinkerink, M.; Gligorov, R.; Steenbergen, Van; Huijkman, J.; Oomen, J.

    2013-01-01

    The Waisda? video labeling game is a crowsourcing tool to collect user-generated metadata for video clips. It follows the paradigm of games-with-a-purpose, where two or more users play against each other by entering tags that describe the content of the video. Players score points by entering the same tags as one of the other players. As a result each video that is played in the game is annotated with tags that are anchored to a time point in the video. Waisda? has been deployed in two projec...

  3. A Food Labeling

    Science.gov (United States)

    ... " ﻗﺎﻧﻮن اﻟﺒﻄﺎﻗﺎت واﻟﺘﻮﻋﻴﺔ اﻟﻐﺬاﺋﻴﺔ " [ Nutrition Labeling and Education Act ... ﻟﻠﻌﺼﻴﺮ اﻟﻤﻜﻮن ﺑﺈﺿﺎﻓﺔ اﻟﻤﺎء إﻟﻰ ﺧﻼﺻﺔ ﻣﺮآﺰة : ﻳﺠﺮى اﻟﺤﺴﺎب ﻣﻦ ﺟﺪول Brix ﻓﻲ 21 CFR 101.30(h)(1) ...

  4. ANALYSIS ON THE SPINNING FORCES IN FLEXIBLE SPINNING OF CONES

    Institute of Scientific and Technical Information of China (English)

    Xia Qinxiang; Susumu Shima

    2003-01-01

    Flexible spinning is a new type of spinning process where spin-forming is performed without using a mandrel. Combining shearing and rolling processes, the calculation formulas of thespinning forces in flexible spinning of cones is presented. The effects of the main processing parameters, such as gripping force G applied to the blank by the inner roller, the feed rate of rollersfand the roundness radius of outer roller ro, on the spinning forces are analyzed experimentally and theoretically.

  5. Spin transfer torques in the nonlocal lateral spin valve.

    Science.gov (United States)

    Xu, Yuan; Xia, Ke; Ma, Zhongshui

    2008-06-11

    We report a theoretical study on the spin and electron transport in the nonlocal lateral spin valve with a non-collinear magnetic configuration. The nonlocal magnetoresistance, defined as the voltage difference on the detection lead over the injected current, is derived analytically. The spin transfer torques on the detection lead are calculated. It is found that spin transfer torques are symmetrical for parallel and antiparallel magnetic configurations, in contrast to that in a conventional sandwiched spin valve. PMID:21825793

  6. Proposal for a spin MOSFET based on spin gapless semiconductors

    OpenAIRE

    Graziosi, Patrizio

    2016-01-01

    We propose a spintronic metal oxide semiconductor field effect transistor (spin MOSFET) where a spin gapless semiconductor (SGS) constitutes the channel and the drain is a ferromagnetic metal. SGS exhibit a non-zero band gap in only one of the spin sub-bands and feature complete spin polarization at finite temperature. We present an analytical model of the device and comment the properties relevant for devices applications. Our results boost SGS as a new paradigm for the spin MOSFET concept.

  7. Towards Multi Label Text Classification through Label Propagation

    Directory of Open Access Journals (Sweden)

    Shweta C. Dharmadhikari

    2012-06-01

    Full Text Available Classifying text data has been an active area of research for a long time. Text document is multifaceted object and often inherently ambiguous by nature. Multi-label learning deals with such ambiguous object. Classification of such ambiguous text objects often makes task of classifier difficult while assigning relevant classes to input document. Traditional single label and multi class text classification paradigms cannot efficiently classify such multifaceted text corpus. Through our paper we are proposing a novel label propagation approach based on semi supervised learning for Multi Label Text Classification. Our proposed approach models the relationship between class labels and also effectively represents input text documents. We are using semi supervised learning technique for effective utilization of labeled and unlabeled data for classification. Our proposed approach promises better classification accuracy and handling of complexity and elaborated on the basis of standard datasets such as Enron, Slashdot and Bibtex.

  8. International Spin Physics 2014 Summary

    CERN Document Server

    Milner, Richard G

    2015-01-01

    The Stern-Gerlach experiment and the origin of electron spin are described in historical context. SPIN 2014 occurs on the fortieth anniversary of the first International High Energy Spin Physics Symposium at Argonne in 1974. A brief history of the international spin conference series is presented.

  9. On Nonlinear Higher Spin Curvature

    OpenAIRE

    Manvelyan, Ruben(Yerevan Physics Institute, Alikhanian Br. St. 2, Yerevan, 0036, Armenia); Mkrtchyan, Karapet; Rühl, Werner; Tovmasyan, Murad

    2011-01-01

    We present the first nonlinear term of the higher spin curvature which is covariant with respect to deformed gauge transformations that are linear in the field. We consider in detail the case of spin 3 after presenting spin 2 as an example, and then construct the general spin s quadratic term of the deWit-Freedman curvature.

  10. On nonlinear higher spin curvature

    Energy Technology Data Exchange (ETDEWEB)

    Manvelyan, Ruben, E-mail: manvel@physik.uni-kl.d [Department of Physics, Erwin Schroedinger Strasse, Technical University of Kaiserslautern, Postfach 3049, 67653 Kaiserslautern (Germany); Yerevan Physics Institute, Alikhanian Br. Str. 2, 0036 Yerevan (Armenia); Mkrtchyan, Karapet, E-mail: karapet@yerphi.a [Department of Physics, Erwin Schroedinger Strasse, Technical University of Kaiserslautern, Postfach 3049, 67653 Kaiserslautern (Germany); Yerevan Physics Institute, Alikhanian Br. Str. 2, 0036 Yerevan (Armenia); Ruehl, Werner, E-mail: ruehl@physik.uni-kl.d [Department of Physics, Erwin Schroedinger Strasse, Technical University of Kaiserslautern, Postfach 3049, 67653 Kaiserslautern (Germany); Tovmasyan, Murad, E-mail: mtovmasyan@ysu.a [Yerevan Physics Institute, Alikhanian Br. Str. 2, 0036 Yerevan (Armenia)

    2011-05-09

    We present the first nonlinear term of the higher spin curvature which is covariant with respect to deformed gauge transformations that are linear in the field. We consider the case of spin 3 after presenting spin 2 as an example, and then construct the general spin s quadratic term of the de Wit-Freedman curvature.

  11. Anisotropic spin relaxation in graphene

    NARCIS (Netherlands)

    Tombros, N.; Tanabe, S.; Veligura, A.; Jozsa, C.; Popinciuc, M.; Jonkman, H. T.; van Wees, B. J.

    2008-01-01

    Spin relaxation in graphene is investigated in electrical graphene spin valve devices in the nonlocal geometry. Ferromagnetic electrodes with in-plane magnetizations inject spins parallel to the graphene layer. They are subject to Hanle spin precession under a magnetic field B applied perpendicular

  12. Microscopic studies of nonlocal spin dynamics and spin transport (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Adur, Rohan; Du, Chunhui; Cardellino, Jeremy; Scozzaro, Nicolas; Wolfe, Christopher S.; Wang, Hailong; Herman, Michael; Bhallamudi, Vidya P.; Pelekhov, Denis V.; Yang, Fengyuan; Hammel, P. Chris, E-mail: hammel@physics.osu.edu [Department of Physics, The Ohio State University, Columbus, Ohio 43210 (United States)

    2015-05-07

    Understanding the behavior of spins coupling across interfaces in the study of spin current generation and transport is a fundamental challenge that is important for spintronics applications. The transfer of spin angular momentum from a ferromagnet into an adjacent normal material as a consequence of the precession of the magnetization of the ferromagnet is a process known as spin pumping. We find that, in certain circumstances, the insertion of an intervening normal metal can enhance spin pumping between an excited ferromagnetic magnetization and a normal metal layer as a consequence of improved spin conductance matching. We have studied this using inverse spin Hall effect and enhanced damping measurements. Scanned probe magnetic resonance techniques are a complementary tool in this context offering high resolution magnetic resonance imaging, localized spin excitation, and direct measurement of spin lifetimes or damping. Localized magnetic resonance studies of size-dependent spin dynamics in the absence of lithographic confinement in both ferromagnets and paramagnets reveal the close relationship between spin transport and spin lifetime at microscopic length scales. Finally, detection of ferromagnetic resonance of a ferromagnetic film using the photoluminescence of nitrogen vacancy spins in neighboring nanodiamonds demonstrates long-range spin transport between insulating materials, indicating the complexity and generality of spin transport in diverse, spatially separated, material systems.

  13. ^3He Spin Pump

    Science.gov (United States)

    Yamaguchi, A.; Ishimoto, H.; Kojima, H.

    2009-03-01

    The superfluid component of ^3He A1 phase is spin-polarized. The process of forcing the superfluid component through a spin filtering structure, in a manner of mechano-magnetic effect, can be used to increase the spin polarization beyond the equilibrium under a given applied magnetic field. We have constructed a test cell in which a glass capillary array acts as the spin (and entropy) filter and an electrostatically actuated diaphragm forces the superfluid flow through it. Preliminary results show that a maximum relative increase of polarization by 50 % could be achieved. The maximum increase in polarization appears to be limited by the critical superfluid flow through the channels in the glass capillary array. The dependence of the observed effects on temperature, pressure and magnetic field will be presented.

  14. Spin-Electromagnetic Hydrodynamics

    CERN Document Server

    Koide, T

    2013-01-01

    The hydrodynamic model including the spin degree of freedom and the electromagnetic field was discussed. In this derivation, we applied electromagnetism for macroscopic medium proposed by Minkowski. For the equation of motion of spin, we assumed that the hydrodynamic equation of the Pauli equation is reproduced when the many-body effect is neglected. The fluid and spin stress tensors induced by the many-body effect were obtained by employing the algebraic positivity of the entropy production in the framework of linear irreversible thermodynamics. In our model, the effect of the spin-magnetic interaction is absorbed into the magnetic polarization so as to satisfy the momentum and angular momentum conservations. We further compared our result with other existing models.

  15. Label and Label-Free Detection Techniques for Protein Microarrays

    Directory of Open Access Journals (Sweden)

    Amir Syahir

    2015-04-01

    Full Text Available Protein microarray technology has gone through numerous innovative developments in recent decades. In this review, we focus on the development of protein detection methods embedded in the technology. Early microarrays utilized useful chromophores and versatile biochemical techniques dominated by high-throughput illumination. Recently, the realization of label-free techniques has been greatly advanced by the combination of knowledge in material sciences, computational design and nanofabrication. These rapidly advancing techniques aim to provide data without the intervention of label molecules. Here, we present a brief overview of this remarkable innovation from the perspectives of label and label-free techniques in transducing nano‑biological events.

  16. Spin and holographic metals

    OpenAIRE

    Alexandrov, Victor; Coleman, Piers

    2012-01-01

    In this paper we discuss two-dimensional holographic metals from a condensed matter physics perspective. We examine the spin structure of the Green's function of the holographic metal, demonstrating that the excitations of the holographic metal are "chiral", lacking the inversion symmetry of a conventional Fermi surface, with only one spin orientation for each point on the Fermi surface, aligned parallel to the momentum. While the presence of a Kramer's degeneracy across the Fermi surface per...

  17. Spin polarizability of hyperons

    Indian Academy of Sciences (India)

    K B Vijaya Kumar

    2014-11-01

    We review the recent progress of the theoretical understanding of spin polarizabilities of the hyperon in the framework of (3) heavy baryon chiral perturbation theory (HBChPT). We present the results of a systematic leading-order calculation of hyperon Compton scattering and extract the forward spin polarizability (0) of hyperons. The results obtained for $_0$ in the case of nucleons agree with the known results of (2) HBChPT when kaon loops are not considered.

  18. Nuclear spin effect in metallic spin valve

    OpenAIRE

    Danon, J.; Nazarov, Yu.V.

    2006-01-01

    We study electronic transport through a ferromagnet normal-metal ferromagnet system and we investigate the effect of hyperfine interaction between electrons and nuclei in the normal-metal part. A switching of the magnetization directions of the ferromagnets causes nuclear spins to precess. We show that the effect of this precession on the current through the system is large enough to be observed in experiment.

  19. Radionuclide evaluation of renal artery dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Born, M.L.; Gerlock, A.J. Jr.; Goncharenko, V.; Hollifield, J.W.; MacDonell, R.C. Jr.

    1981-01-01

    Radionuclide studies were used in three patients to evaluate renal perfusion and function within 24 hours following transluminal dilatation. In one patient, technetium-99 m pertechnetate showed good renal perfusion one and 12 hours after a post-dilatation arteriogram had shown a renal artery intimal defect. Improved clearance of iodine-131 ortho-iodohippurate from the blood demonstrated an increase in renal function 18 hours following dilatation of a stenosis at a renal allograft anastomosis in the second patient, while technetium-99 m-labeled DTPA showed an improved total glomerular filtration rate 24 hours after dilatation of a saphenous vein bypass graft in the third patient. It was concluded that renal radionuclide studies are of benefit in evaluating patients in the immediate post-dilatation period.

  20. Spin transport in nanoscale spin valves and magnetic tunnel junctions

    Science.gov (United States)

    Patibandla, Sridhar

    Spintronics or electronics that utilizes the spin degree of freedom of a single charge carrier (or an ensemble of charge carriers) to store, process, sense or communicate data and information is a rapidly burgeoning field in electronics. In spintronic devices, information is encoded in the spin polarization of a single carrier (or multiple carriers) and the spin(s) of these carrier(s) are manipulated for device operation. This strategy could lead to devices with low power consumption. This dissertation investigates spin transport in one dimensional and two dimensional semiconductors, with a view to applications in spintronic devices. This dissertation is arranged as follows: Chapter 1 gives a detailed introduction and necessary background to understand aspects of spin injection into a semiconductor from a spin polarized source such as a ferromagnet, and spin polarized electron transport in the semiconductor. Chapter 2 discusses the nanoporous alumina technique that is employed to fabricate nanowires and nanowire spin valves for the investigation of spin transport in 1D semiconductors. Chapter 3 investigates the spin transport in quasi one-dimensional spin valves with germanium spacer layer. These spin valves with 50nm in diameter and 1 mum length were fabricated using the porous alumina technique. Spin transport in nanoscale germanium spin valves was demonstrated and the spin relaxation lengths and the spin relaxation times were calculated. Chapter 4 discusses spin transport studies conducted in bulk high purity germanium with a view to comparing spin relaxation mechanisms in low mobility nanowires and high mobility bulk structures. Lateral spin valve with tunnel injectors were employed in this study and the spin transport measurements were conducted at various temperatures. The spin relaxation rates were measured as a function of temperature which allowed us to distinguish between two different mechanisms---D'yakonov-Perel' and Elliott-Yafet---that dominate spin

  1. Theory of spin Hall effect

    OpenAIRE

    Chudnovsky, Eugene M.

    2007-01-01

    An extension of Drude model is proposed that accounts for spin and spin-orbit interaction of charge carriers. Spin currents appear due to combined action of the external electric field, crystal field and scattering of charge carriers. The expression for spin Hall conductivity is derived for metals and semiconductors that is independent of the scattering mechanism. In cubic metals, spin Hall conductivity $\\sigma_s$ and charge conductivity $\\sigma_c$ are related through $\\sigma_s = [2 \\pi \\hbar...

  2. Edge colouring by total labellings

    DEFF Research Database (Denmark)

    Brandt, Stephan; Rautenbach, D.; Stiebitz, M.;

    2010-01-01

    We introduce the concept of an edge-colouring total k-labelling. This is a labelling of the vertices and the edges of a graph G with labels 1, 2, ..., k such that the weights of the edges define a proper edge colouring of G. Here the weight of an edge is the sum of its label and the labels of its...... two endvertices. We define χ (G) to be the smallest integer k for which G has an edge-colouring total k-labelling. This parameter has natural upper and lower bounds in terms of the maximum degree Δ of G : ⌈ (Δ + 1) / 2 ⌉ ≤ χ (G) ≤ Δ + 1. We improve the upper bound by 1 for every graph and prove χ (G...

  3. A Better Carbon Footprint Label

    DEFF Research Database (Denmark)

    Thøgersen, John; Nielsen, Kristian S.

    2016-01-01

    Based on insights from behavioral economics, it is suggested to extend carbon footprint labeling with information about relative performance, using the well-known “traffic light” color scheme to communicate relative performance. To test this proposition, the impact of a carbon footprint label......, participants saw the original Carbon Trust label and in the other condition they saw the same label, but with traffic light colors added to communicate the product's relative performance in terms of carbon footprint. All included attributes were found to have a significant impact on consumer choices...... to indicate relative carbon footprint significantly increases carbon label effectiveness. Hence, a carbon footprint label is more effective if it uses traffic light colors to communicate the product's relative performance....

  4. Modeling the effects of labeling

    DEFF Research Database (Denmark)

    Juhl, Hans Jørn; Fjord, Thomas Ahle; Poulsen, Carsten Stig

    A new approach to evaluate the consequences of labeling is presented and applied to test the potential effect of a label on fresh fish. Labeling effects on quality perceptions and overall quality are studied. The empirical study is based on an experimental design and nearly 500 respondents partic...... participated in an in home test. The results indicate that catch time alone is not enough to work as an efficient predictor of actual perceived quality.......A new approach to evaluate the consequences of labeling is presented and applied to test the potential effect of a label on fresh fish. Labeling effects on quality perceptions and overall quality are studied. The empirical study is based on an experimental design and nearly 500 respondents...

  5. Electrical detection of spin accumulation and spin precession at room temperature in metallic spin valves

    NARCIS (Netherlands)

    Jedema, F.J.; Costache, M.V.; Heersche, H.B.; Baselmans, J.J.A.; Wees, B.J. van

    2002-01-01

    We have fabricated a multiterminal lateral mesoscopic metallic spin valve demonstrating spin precession at room temperature (RT), using tunnel barriers in combination with metallic ferromagnetic electrodes as a spin injector and detector. The observed modulation of the output signal due to the spin

  6. Spin heat accumulation and spin-dependent temperatures in nanopillar spin valves

    NARCIS (Netherlands)

    Dejene, F. K.; Flipse, J.; Bauer, G. E. W.; van Wees, B. J.

    2013-01-01

    Since the discovery of the giant magnetoresistance effect(1,2) the intrinsic angular momentum of the electron has opened up new spin-based device concepts. Our present understanding of the coupled transport of charge, spin and heat relies on the two-channel model for spin-up and spin-down electrons

  7. Assessment of the accumulation of technetium-99m labelled leukocytes in the treatment of the infections of vascular prosthesis

    International Nuclear Information System (INIS)

    The purpose of this is to evaluate the accumulation of technetium-99m-labelled leukocytes after change of vascular, dacron and infected prosthetic graft in arterial homo grafts harvested from multiorgan-procurement - with own computer program. In this paper 11 cases of aorto-ilio-femoral graft infection treated by the replacement of infected prosthesis with fresh, bifurcated, arterial homografts is presented. In all patients clinical investigations revealed vascular prosthesis infection with the rupture of vascular anastomoses between the prosthesis' branch and wall of artery that resulted with hemorrhage. The Duplex- Doppler ultrasound and the scintigraphy with use of technetium-labeled leucocytes were used in the diagnostic trial of infection and of the healing process of the arterial homografts.The area of the accumulation of 99mTc labelled leukocytes was evaluated with own computer programs. Positive clinical effect was obtained in all patients.The regression of infection after in situ replacement of the synthetic prosthesis with homograft was presented with the scintigraphic examination: in these patients the area of leukocytes accumulation decreased from 34±3 cm2 to 9±2cm2. The use of scintigraphy with 99mTc labelled leukocytes to evaluate the healing process of the arterial homografts in therapy of the prosthetic graft is a the accumulation of leucocytes is facilitation in the monitoring of regression of infection. (author)

  8. Staphylococcus aureus Peptidoglycan Tertiary Structure from Carbon-13 Spin Diffusion

    OpenAIRE

    Sharif, Shasad; Singh, Manmilan; Kim, Sung Joon; Schaefer,Jacob

    2009-01-01

    The cell-wall peptidoglycan of Staphylococcus aureus is a heterogeneous, highly cross-linked polymer of unknown tertiary structure. We have partially characterized this structure by measuring spin diffusion from 13C labels in pentaglycyl cross-linking segments to natural-abundance 13C in the surrounding intact cell walls. The measurements were performed using a version of centerband-only detection of exchange (CODEX). The cell walls were isolated from S. aureus grown in media containing [1-13...

  9. Classification and Labelling for Biocides

    OpenAIRE

    Rubbiani, Maristella

    2015-01-01

    CLP and biocides The EU Regulation (EC) No 1272/2008 on Classification, Labelling and Packaging of Substances and Mixtures, the CLP-Regulation, entered into force on 20th January, 2009. Since 1st December, 2010 the classification, labelling and packaging of substances has to comply with this Regulation. For mixtures, the rules of this Regulation are mandatory from 1st June, 2015; this means that until this date classification, labelling and packaging could either be carried out according to D...

  10. Aggregating Labels in Crowdsourcing Data

    OpenAIRE

    Priisalu, Maria; Grey, Francois; Segal, Ben

    2015-01-01

    Project Specification Crowdsourcing is gaining popularity in academia with the launch of crowdsourcing platforms such as Crowdcrafting [Lombraña, 2015] and GeoTagX [UNOSAT, 2015]. There have been a number of proposed algorithms for the aggregation of true labels and a confusion matrix from crowdsourced labels for ordinal, nominal and binary labels. The work here consists of an implementation of the Dawid Skene [Dawid 1979] adaptation of the Expectation Maximization algorithm [D...

  11. Caliber-Persistent Artery

    Directory of Open Access Journals (Sweden)

    Sabrina Araújo Pinho Costa

    2015-01-01

    Full Text Available Caliber-persistent artery (CPLA of the lip is a common vascular anomaly in which a main arterial branch extends to the surface of the mucous tissue with no reduction in its diameter. It usually manifests as pulsatile papule, is easily misdiagnosed, and is observed more frequently among older people, suggesting that its development may involve a degenerative process associated with aging; CPLA is also characterized by the loss of tone of the adjacent supporting connective tissue. Although the diagnosis is clinical, high-resolution Doppler ultrasound is a useful noninvasive tool for evaluating the lesion. This report describes the case of a 58-year-old male patient who complained of a lesion of the lower lip with bleeding and recurrent ulceration. The patient was successfully treated in our hospital after a diagnosis of CPLA and is currently undergoing a clinical outpatient follow-up with no complaints.

  12. Spin photonics and spin-photonic devices with dielectric metasurfaces

    CERN Document Server

    Liu, Yachao; Ke, Yougang; Zhou, Xinxing; Luo, Hailu; Wen, Shuangchun

    2015-01-01

    Dielectric metasurfaces with spatially varying birefringence and high transmission efficiency can exhibit exceptional abilities for controlling the photonic spin states. We present here some of our works on spin photonics and spin-photonic devices with metasurfaces. We develop a hybrid-order Poincare sphere to describe the evolution of spin states of wave propagation in the metasurface. Both the Berry curvature and the Pancharatnam-Berry phase on the hybrid-order Poincare sphere are demonstrated to be proportional to the variation of total angular momentum. Based on the spin-dependent property of Pancharatnam-Berry phase, we find that the photonic spin Hall effect can be observed when breaking the rotational symmetry of metasurfaces. Moreover, we show that the dielectric metasurfaces can provide great flexibility in the design of novel spin-photonic devices such as spin filter and spin-dependent beam splitter.

  13. Quantum Computation Based on Magic-Angle-Spinning Solid State Nuclear Magnetic Resonance Spectroscopy

    OpenAIRE

    Ding, Shangwu; McDowell, Charles A.; Ye, Chaohui; Zhan, Mingsheng; Zhu, Xiwen; Gao, Kelin; Sun, Xianping; Mao, Xi-An; Liu, Maili

    2001-01-01

    Magic-angle spinning (MAS) solid state nuclear magnetic resonance (NMR) spectroscopy is shown to be a promising technique for implementing quantum computing. The theory underlying the principles of quantum computing with nuclear spin systems undergoing MAS is formulated in the framework of formalized quantum Floquet theory. The procedures for realizing state labeling, state transformation and coherence selection in Floquet space are given. It suggests that by this method, the largest number o...

  14. Cern News The Higgs or not the Higgs. Spin will tell. Part 2

    CERN Multimedia

    CERN Visual Media Office; Paola Catapano

    2012-01-01

    Second part of the videonews explaining why the newly found boson at the LHC cannot yet be labelled the Higgs boson and what is the spin of a particle. In this seconfd part, Higgs searches conveners Christopher Paus (CMS) and Aidan Randle (ATLAS) and theoretical physicist John Ellis provide the latest information on the spin of the presumed Higgs boson, on the already excluded values and the open questions.

  15. Spin-Current and Spin-Splitting in Helicoidal Molecules Due to Spin-Orbit Coupling.

    Science.gov (United States)

    Caetano, R A

    2016-01-01

    The use of organic materials in spintronic devices has been seriously considered after recent experimental works have shown unexpected spin-dependent electrical properties. The basis for the confection of any spintronic device is ability of selecting the appropriated spin polarization. In this direction, DNA has been pointed out as a potential candidate for spin selection due to the spin-orbit coupling originating from the electric field generated by accumulated electrical charges along the helix. Here, we demonstrate that spin-orbit coupling is the minimum ingredient necessary to promote a spatial spin separation and the generation of spin-current. We show that the up and down spin components have different velocities that give rise to a spin-current. By using a simple situation where spin-orbit coupling is present, we provide qualitative justifications to our results that clearly point to helicoidal molecules as serious candidates to integrate spintronic devices. PMID:27009836

  16. Spin Torques in Systems with Spin Filtering and Spin Orbit Interaction

    KAUST Repository

    ortiz pauyac, christian

    2016-06-19

    In the present thesis we introduce the reader to the field of spintronics and explore new phenomena, such as spin transfer torques, spin filtering, and three types of spin-orbit torques, Rashba, spin Hall, and spin swapping, which have emerged very recently and are promising candidates for a new generation of memory devices in computer technology. A general overview of these phenomena is presented in Chap. 1. In Chap. 2 we study spin transfer torques in tunnel junctions in the presence of spin filtering. In Chap. 3 we discuss the Rashba torque in ferromagnetic films, and in Chap. 4 we study spin Hall effect and spin swapping in ferromagnetic films, exploring the nature of spin-orbit torques based on these mechanisms. Conclusions and perspectives are summarized in Chap. 5.

  17. Gestational pulmonary arterial hypertension

    OpenAIRE

    Moll, Matthew; Payne, Julie G.; Tukey, Melissa H.; Farber, Harrison W.

    2015-01-01

    Pulmonary arterial hypertension (PAH) is a progressive disease marked by the irreversible pulmonary vascular changes of vasoconstriction, thrombosis, and proliferation of smooth muscle and endothelial cells. The untreated clinical course is characterized by progressive dyspnea and a median survival of less than 3 years. Many of these patients are of child-bearing age; however, pregnancy leads to physiologic changes that are particularly poorly tolerated in PAH, conferring a 30%–56% mortality....

  18. CAROTID ARTERY DISEASE

    OpenAIRE

    Van Damme, H

    2009-01-01

    Carotid artery disease (CAD) become a commonly seen disease in general medical practice, due to the general population aging. Stroke, one of the most frequent complications of CAD and represents the third cause of death in Western countries. The leading cause of stroke in CAD is atheroembolism rather than flow-reduction. This paper reviewed imaging techniques, medical treatment and esepecially carotid endarterectomy (from point of view of indications, surgical technique and results) and caro...

  19. Sustainability labels on food products

    DEFF Research Database (Denmark)

    Grunert, Klaus G; Hieke, Sophie; Wills, Josephine

    2014-01-01

    This study investigates the relationship between consumer motivation, understanding and use of sustainability labels on food products (both environmental and ethical labels), which are increasingly appearing on food products. Data was collected by means of an online survey implemented in the UK......, human values as measured by the Schwartz value domains, and country differences. The results imply that sustainability labels currently do not play a major role in consumers’ food choices, and future use of these labels will depend on the extent to which consumers’ general concern about sustainability...

  20. The radioactive labeling of monocytes

    International Nuclear Information System (INIS)

    With the aim of studying a possible relationship between circulating monocytes and Sternberg-Reed cells investigations were started on the specific labeling of monocytes. In this thesis the literature on the pertinent data has been reviewed and a series of experiments on the monocyte labeling procedure has been described. The principles of cell labeling with radioactive compounds were discussed. 1. Total separation of the particular cell population to be labeled and subsequent labeling with a non-specific radiopharmaceutical. 2. Specific cell labeling in a mixture of cell types based on a well defined affinity of the cell under study for the radiopharmaceutical used. Next the radionuclides that can be used for cell labeling purposes were discussed with special attention for 111In and its chelates. The principles of radiodosimetry were also discussed shortly. This section was focussed on the radiation dose the labeled cells receive because of the intracellular localized radioactivity. The radiation burden is high in comparison to amounts of radiation known to affect cell viability. A newly developed method for labeling monocytes specifically by phagocytosis of 111In-Fe-colloid without apparent loss of cells was described in detail. (Auth.)

  1. Separating Inverse spin Hall voltage and spin rectification voltage by inverting spin injection direction

    OpenAIRE

    Zhang, Wenxu; Peng, Bin; Han, Fangbin; Wang, Qiuru; Soh, Wee Tee; Ong, C. K.; Zhang, WanLi

    2015-01-01

    We develop a method for universally resolving the important issue of separating the inverse spin Hall effect (ISHE) from spin rectification effect (SRE) signal. This method is based on the consideration that the two effects depend on the spin injection direction: The ISHE is an odd function of the spin injection direction while the SRE is independent on it. Thus, inversion of the spin injection direction changes the ISHE voltage signal, while SRE voltage remains. It applies generally to analy...

  2. Case Report: Coronary arterial spasm in single right coronary artery

    Institute of Scientific and Technical Information of China (English)

    En-zhi JIA; Qi-jun SHAN; Zhi-jian YANG; Tie-bing ZHU; Lian-sheng WANG; Ke-jiang CAO; Wen-zhu MA

    2009-01-01

    We presented a case of anomalous single-coronary artery detected incidentally during routine coronary angiography. A 32-year-old male Chinese patient presented with recurrent pre-syncope and six episodes of syncope. Coronary angiography and coronary-computed tomography (CT)-angiography performed by a dual-source computed tomography (DSCT) revealed that the patient had a single large right coronary artery. A moderately large branch originated from the proximal part of the single right coronary artery and extended to the left, passing the anterior to the pulmonary artery, and divided into the anterior descending artery branch and circumflex branch at the base of the left auricular appendage. The episodes of the syncope were suspected to be caused by coronary arterial spasm, so this patient was on a regimen of 30 mg of diltiazem every 6 h and had no recurrence of syncope during follow-up.

  3. Laser labeling, a safe technology to label produce

    Science.gov (United States)

    Laser labeling of fruits and vegetables is an alternative means to label produce. Low energy CO2 laser beams etch the surface showing the contrasting underlying layer. These etched surfaces can promote water loss and potentially allow for entry of decay organisms. The long-term effects of laser labe...

  4. 76 FR 75809 - Prior Label Approval System: Generic Label Approval

    Science.gov (United States)

    2011-12-05

    ... the type of packaging material on which the label is printed; n. Brand name changes, provided that... poultry products will take effect January 1, 2012 (75 FR 82148, Dec. 29, 2010). These mandatory features..., location, and indication of final color. To obtain sketch label approval, domestic meat and...

  5. Measurements of nuclear spin dynamics by spin-noise spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ryzhov, I. I.; Poltavtsev, S. V.; Kozlov, G. G.; Zapasskii, V. S. [Spin Optics Laboratory, St. Petersburg State University, 1 Ul' anovskaya, Peterhof, St. Petersburg 198504 (Russian Federation); Kavokin, K. V.; Glazov, M. M. [Spin Optics Laboratory, St. Petersburg State University, 1 Ul' anovskaya, Peterhof, St. Petersburg 198504 (Russian Federation); Ioffe Institute, Russian Academy of Sciences, 26 Polytechnicheskaya, St.-Petersburg 194021 (Russian Federation); Vladimirova, M.; Scalbert, D.; Cronenberger, S. [Laboratoire Charles Coulomb UMR 5221 CNRS/Université de Montpellier, Place Eugene Bataillon, 34095 Montpellier Cedex 05 (France); Kavokin, A. V. [Spin Optics Laboratory, St. Petersburg State University, 1 Ul' anovskaya, Peterhof, St. Petersburg 198504 (Russian Federation); School of Physics and Astronomy, University of Southampton, SO17 1NJ Southampton (United Kingdom); Lemaître, A.; Bloch, J. [Laboratoire de Photonique et de Nanostructures, UPR CNRS, Route de Nozay, 91460 Marcoussis (France)

    2015-06-15

    We exploit the potential of the spin noise spectroscopy (SNS) for studies of nuclear spin dynamics in n-GaAs. The SNS experiments were performed on bulk n-type GaAs layers embedded into a high-finesse microcavity at negative detuning. In our experiments, nuclear spin polarisation initially prepared by optical pumping is monitored in real time via a shift of the peak position in the electron spin noise spectrum. We demonstrate that this shift is a direct measure of the Overhauser field acting on the electron spin. The dynamics of nuclear spin is shown to be strongly dependent on the electron concentration.

  6. Amplification of Spin Waves by Thermal Spin-Transfer Torque

    Science.gov (United States)

    Padrón-Hernández, E.; Azevedo, A.; Rezende, S. M.

    2011-11-01

    We observe amplification of spin-wave packets propagating along a film of single-crystal yttrium iron garnet subject to a transverse temperature gradient. The spin waves are excited and detected with standard techniques used in magnetostatic microwave delay lines in the 1-2 GHz frequency range. The amplification is attributed to the action of a thermal spin-transfer torque acting on the magnetization that opposes the relaxation and which is created by spin currents generated through the spin-Seebeck effect. The experimental data are interpreted with a spin-wave model that gives an amplification gain in very good agreement with the data.

  7. Oxygen labelled CO2

    International Nuclear Information System (INIS)

    Tests were carried out as to whether additional information concerning pulmonary gas exchange could be obtained from the application of oxygen labelled carbon dioxide. Single breath experiments were performed on two healthy subjects with 0.1 percent C16O18O and 2.8 percent C18O2 in the inspiratory gas. Breath-hold time was varied between 0.5-20s in different experiments. The 18O-concentration of the end-expired gas bi-exponentially decreased with increasing breath-hold time. The high and low rate constants 4s-1 and 0.12s-1 for C18O2 and 2.5s-1 and 0.87s-1 for C16O18O were derived, respectively. These results, together with model calculations, suggest: 1) the rapid disappearance of C18O2 from the alveolar space is primarily limited by diffusion, so that this isotopic species can be applied to quantify pulmonary diffusing conditions; 2) the lower disappearance rate of C16O18O is caused by a lower equilibration kinetics in blood, so that this isotopic species offers a possibility to study carbonic anhydrase activity of the red cells in vivo; 3) the slow phase of label decay is influenced by both alveolar dead space and carbonic anhydrase activity of the pulmonary tissues. Pathological dead spaces are expected to be sensitively detectable by C16O18O as well as by C18O2. (author). 4 refs.; 4 figs

  8. Arterial stiffness as a risk factor for coronary artery disease.

    Science.gov (United States)

    Liao, Josh; Farmer, John

    2014-02-01

    Hypertension is a major modifiable risk factor, and clinical trials have demonstrated that successful reduction of elevated blood pressure to target levels translates into decreased risk for the development of coronary artery disease, stroke, heart failure, and renal failure. The arterial system had previously been regarded as a passive conduit for the transportation of arterial blood to peripheral tissues. The physiologic role the arterial system was greatly expanded by the recognition of the central role of the endothelial function in a variety of physiologic processes. The role of arterial function and structure in cardiovascular physiology was expanded with the development of a variety of parameters that evaluate arterial stiffness. Markers of arterial stiffness have been correlated with cardiovascular outcomes, and have been classified as an emerging risk factor that provides prognostic information beyond standard stratification strategies involving hypertension, diabetes, obesity, dyslipidemia and smoking. Multiple epidemiologic studies have correlated markers of arterial stiffness such as pulse-wave velocity, augmentation index and pulse pressure with risk for the development of fatal and nonfatal cardiovascular events. Additionally, measurements of arterial stiffness had clarified the results of clinical trials that demonstrated differing impacts on clinical outcomes, despite similar reductions in blood pressure, as measured by brachial and sphygmomanometry.

  9. Contribution of the vertebral artery to cerebral circulation in the rat snake Elaphe obsoleta

    Science.gov (United States)

    Zippel, K. C.; Lillywhite, H. B.; Mladinich, C. R.; Hargens, A. (Principal Investigator)

    1998-01-01

    Blood supplying the brain in vertebrates is carried primarily by the carotid vasculature. In most mammals, cerebral blood flow is supplemented by the vertebral arteries, which anastomose with the carotids at the base of the brain. In other tetrapods, cerebral blood is generally believed to be supplied exclusively by the carotid vasculature, and the vertebral arteries are usually described as disappearing into the dorsal musculature between the heart and head. There have been several reports of a vertebral artery connection with the cephalic vasculature in snakes. We measured regional blood flows using fluorescently labeled microspheres and demonstrated that the vertebral artery contributes a small but significant fraction of cerebral blood flow (approximately 13% of total) in the rat snake Elaphe obsoleta. Vascular casts of the anterior vessels revealed that the vertebral artery connection is indirect, through multiple anastomoses with the inferior spinal artery, which connects with the carotid vasculature near the base of the skull. Using digital subtraction angiography, fluoroscopy, and direct observations of flow in isolated vessels, we confirmed that blood in the inferior spinal artery flows craniad from a point anterior to the vertebral artery connections. Such collateral blood supply could potentially contribute to the maintenance of cerebral circulation during circumstances when craniad blood flow is compromised, e.g., during the gravitational stress of climbing.

  10. Spin Hall and Spin Nernst effect from first principles

    Science.gov (United States)

    Mertig, Ingrid

    2013-03-01

    Spintronics without magnetic materials is an interesting alternative to the existing spintronics applications. The spin Hall effect creates spin currents in nonmagnetic materials and avoids the problem of spin injection. Future applications of the spin Hall effect require two properties of the materials, a large spin Hall angle and a long spin diffusion length. Ab intio calculations based on density functional theory are a powerful tool to design the desired materials and to get insight into the underlying microscopic processes. We investigated the spin Hall effect in dilute alloys, in particular the intrinsic effect based on the Berry curvature as well as side-jump and the skew-scattering contributions. The results demonstrate that a large extrinsic spin Hall effect is determined by the differences between host and impurity concerning the spin-orbit interaction. It can be caused by light p scatterers as C and N in Au. A comparable large effect is observed for heavy p scatterers as Bi in Cu. An alternative way is to deposit impurities in the adatom position. Furthermore, we predict a spin current perpendicular to a temperature gradient. The phenomenon is called spin Nernst effect. The predicted spin currents can be comparably large as in the case of the spin Hall effect.

  11. Fredkin Spin Chain

    CERN Document Server

    Salberger, Olof

    2016-01-01

    We introduce a new model of interacting spin 1/2. It describes interaction of three nearest neighbors. The Hamiltonian can be expressed in terms of Fredkin gates. The Fredkin gate (also known as the CSWAP gate) is a computational circuit suitable for reversible computing. Our construction generalizes the work of Ramis Movassagh and Peter Shor. Our model can be solved by means of Catalan combinatorics in the form of random walks on the upper half of a square lattice [Dyck walks]. Each Dyck path can be mapped to a wave function of the spins. The ground state is an equally weighted superposition of Dyck walks [instead of Motzkin walks]. We can also express it as a matrix product state. We further construct the model of interacting spins 3/2 and greater half-integer spins. The models with higher spins require coloring of Dyck walks. We construct SU(k) symmetric model [here k is the number of colors]. The leading term of the entanglement entropy is then proportional to the square root of the length of the lattice ...

  12. Spin hydrodynamic generation

    Science.gov (United States)

    Takahashi, R.; Matsuo, M.; Ono, M.; Harii, K.; Chudo, H.; Okayasu, S.; Ieda, J.; Takahashi, S.; Maekawa, S.; Saitoh, E.

    2016-01-01

    Magnetohydrodynamic generation is the conversion of fluid kinetic energy into electricity. Such conversion, which has been applied to various types of electric power generation, is driven by the Lorentz force acting on charged particles and thus a magnetic field is necessary. On the other hand, recent studies of spintronics have revealed the similarity between the function of a magnetic field and that of spin-orbit interactions in condensed matter. This suggests the existence of an undiscovered route to realize the conversion of fluid dynamics into electricity without using magnetic fields. Here we show electric voltage generation from fluid dynamics free from magnetic fields; we excited liquid-metal flows in a narrow channel and observed longitudinal voltage generation in the liquid. This voltage has nothing to do with electrification or thermoelectric effects, but turned out to follow a universal scaling rule based on a spin-mediated scenario. The result shows that the observed voltage is caused by spin-current generation from a fluid motion: spin hydrodynamic generation. The observed phenomenon allows us to make mechanical spin-current and electric generators, opening a door to fluid spintronics.

  13. True aneurysm of brachial artery.

    Science.gov (United States)

    Hudorović, Narcis; Lovričević, Ivo; Franjić, Dario Bjorn; Brkić, Petar; Tomas, Davor

    2010-10-01

    True upper extremity peripheral artery aneurysms are a rarely encountered arterial disorder. Following computer-tomography angiographic (CT-a) imaging examination, true saccular aneurysm, originating from the left brachial artery was diagnosed in the 77-year-old female without history of trauma. The aneurysm was resected by surgical intervention, and primary repair of the brachial artery was performed by interposition of a part of great saphenous vein harvested from the left groin and creation of two end-to-end anastomoses between interposition graft and previously resected part of brachial artery. No complication was observed during the follow-up. Surgical intervention for upper extremity aneurysms should be initiated without delay. Factors combined with minimal morbidity associated with repair suggest that surgical repair should be performed routinely for true upper extremity arterial aneurysms. PMID:20865459

  14. Arterial responses during migraine headache

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Olesen, J;

    1990-01-01

    The superficial temporal artery has been thought to be the main focus of pain during migraine attacks, but its diameter has never been measured directly. The use of a new, high-resolution ultrasound machine to measure arterial size in 25 migraine patients with unilateral head pain showed...... that the lumen was wider on the painful than on the non-painful side during a migraine attack. The diameters of both radial arteries and the temporal artery on the non-painful side were smaller during than between attacks. The generalised vasoconstriction was not shared by the temporal artery on the affected...... side, which suggests a local vasodilatory response. The findings suggest that cephalic arteries may play a role in migraine pathogenesis....

  15. Spin Structures in Magnetic Nanoparticles

    DEFF Research Database (Denmark)

    Mørup, Steen; Brok, Erik; Frandsen, Cathrine

    2013-01-01

    Spin structures in nanoparticles of ferrimagnetic materials may deviate locally in a nontrivial way from ideal collinear spin structures. For instance, magnetic frustration due to the reduced numbers of magnetic neighbors at the particle surface or around defects in the interior can lead to spin...... canting and hence a reduced magnetization. Moreover, relaxation between almost degenerate canted spin states can lead to anomalous temperature dependences of the magnetization at low temperatures. In ensembles of nanoparticles, interparticle exchange interactions can also result in spin reorientation....... Here, we give a short review of anomalous spin structures in nanoparticles....

  16. Nutrition Marketing on Food Labels

    Science.gov (United States)

    Colby, Sarah E.; Johnson, LuAnn; Scheett, Angela; Hoverson, Bonita

    2010-01-01

    Objective: This research sought to determine how often nutrition marketing is used on labels of foods that are high in saturated fat, sodium, and/or sugar. Design and Setting: All items packaged with food labels (N = 56,900) in all 6 grocery stores in Grand Forks, ND were surveyed. Main Outcome Measure(s): Marketing strategy, nutrient label…

  17. Meat and Poultry Labeling Terms

    Science.gov (United States)

    ... Food Standards and Labels: The Facts Labeling and Marketing Information [ Top of Page ] OVEN PREPARED: Product is fully cooked and ready to eat. [ Top of Page ] YOUNG TURKEY: Turkeys of either sex that are less than 8 months of age according to present regulations. [ Top of Page ] Last ...

  18. MRI and MR angiography of vertebral artery dissection

    Energy Technology Data Exchange (ETDEWEB)

    Mascalchi, M. [Cattedra di Radiologia, Universita di Pisa (Italy); Bianchi, M.C. [Servizio di Neuroradiologia, Ospedale S. Chiara, Pisa (Italy); Mangiafico, S. [Servizio di Neuroradiologia, Ospedale di Careggi, Firenze (Italy); Ferrito, G. [Servizio di Neuroradiologia, Ospedali Riuniti, Livorno (Italy); Puglioli, M. [Servizio di Neuroradiologia, Ospedale S. Chiara, Pisa (Italy); Marin, E. [Servizio di Radiologia, Ospedale S. M. Nuova, Firenze (Italy); Mugnai, S. [Clinica Neurologica, Universita di Firenze (Italy); Canapicchi, R. [Servizio di Neuroradiologia, Ospedale S. Chiara, Pisa (Italy); Quilici, N. [Servizio di Neuroradiologia, Ospedali Riuniti, Livorno (Italy); Inzitari, D. [Clinica Neurologica, Universita di Firenze (Italy)

    1997-05-01

    A review of 4,500 angiograms yielded 11 patients with dissection of the vertebral arteries who had MRI and (in 4 patients) MR angiography (MRA) in the acute phase of stroke. One patient with incidental discovery at arteriography of asymptomatic vertebral artery dissection and two patients with acute strokes with MRI and MRA findings consistent with vertebral artery dissection were included. Dissection occurred after neck trauma or chiropractic manipulation in 4 patients and was spontaneous in 10. Dissection involved the extracranial vertebral artery in 9 patients, the extra-intracranial junction in 1, and the intracranial artery in 4. MRI demonstrated infarcts in the brain stem, cerebellum, thalamus or temporo-occipital regions in 7 patients with extra- or extra-intracranial dissections and a solitary lateral medullary infarct in 4 patients (3 with intracranial and 1 with extra-intracranial dissection). In 2 patients no brain abnormality related to vertebral artery dissection was found and in one MRI did not show subarachnoid haemorrhage revealed by CT. Intramural dissecting haematoma appeared as crescentic or rounded high signal on T1-weighted images in 10 patients examined 3-20 days after the onset of symptoms. The abnormal vessel stood out in the low signal cerebrospinal fluid in intracranial dissections, whereas it was more difficult to detect in extracranial dissections because of the intermediate-to-high signal of the normal perivascular structures and slow flow proximal and distal to the dissection. In two patients examined within 36 h of the onset, mural thickening was of intermediate signal intensity on T1-weighted images and high signal on spin-density and T2-weighted images. MRA showed abrupt stenosis in 2 patients and disappearance of flow signal at and distal to the dissection in 5. Follow-up arteriography, MRI or MRA showed findings consistent with occlusion of the dissected vessel in 6 of 8 patients. (orig.). With 7 figs., 3 tabs.

  19. The right hepatic artery syndrome

    Institute of Scientific and Technical Information of China (English)

    Kazumi Miyashita; Katsuya Shiraki; Takeshi Ito; Hiroki Taoka; Takeshi Nakano

    2005-01-01

    Various benign and malignant conditions could cause biliary obstruction. Compression of extrahepatic bile duct (EBD) by right hepatic artery was reported as a right hepatic artery syndrome but all cases were compressed EBD from stomach side. Our case compressed from dorsum was not yet reported, so it was thought to be a very rare case. We present here the first case of bile duct obstruction due to the compression of EBD from dorsum by right hepatic artery.

  20. Fermi spin current contribution in spin wave spectrum of spin-1/2 fermions

    Science.gov (United States)

    Andreev, Pavel; Kuzmenkov, Leonid

    2016-05-01

    General theory predicts the presence of the thermal part of the spin current in the spin evolution equation for bosons and fermions. For bosons in Bose-Einstein condensate state, it is equal to zero. However, for degenerate fermions it is non zero and it can give a considerable contribution since it describes the Pauli blocking. In this work, we consider spin-1/2 partially polarized fermions. We derive an equation of state for the thermal part of the spin current of degenerate fermions and call it Fermi spin current. We present the spin evolution equation with the Fermi spin current as a part of applied hydrodynamic model. We consider spectrum of collective excitation and describe contribution of the Fermi spin current in the spin wave spectrum. The work of P.A. was supported by the Russian Foundation for Basic Research (Grant No. 16-32-00886) and the Dynasty foundation.

  1. Spin filter and spin valve in ferromagnetic graphene

    Science.gov (United States)

    Song, Yu; Dai, Gang

    2015-06-01

    We propose and demonstrate that a EuO-induced and top-gated graphene ferromagnetic junction can be simultaneously operated as a spin filter and a spin valve. We attribute such a remarkable result to a coexistence of a half-metal band and a common energy gap for opposite spins in ferromagnetic graphene. We show that both the spin filter and the spin valve can be effectively controlled by a back gate voltage, and they survive for practical metal contacts and finite temperature. Specifically, larger single spin currents and on-state currents can be reached with contacts with work functions similar to graphene, and the spin filter can operate at higher temperature than the spin valve.

  2. Spin rectification induced by spin Hall magnetoresistance at room temperature

    Science.gov (United States)

    Wang, P.; Jiang, S. W.; Luan, Z. Z.; Zhou, L. F.; Ding, H. F.; Zhou, Y.; Tao, X. D.; Wu, D.

    2016-09-01

    We have experimentally and theoretically investigated the dc voltage generation in the heterostructure of Pt and yttrium iron garnet under the ferromagnetic resonance. Besides a symmetric Lorenz line shape dc voltage, an antisymmetric Lorenz line shape dc voltage is observed in field scan, which can solely originate from the spin rectification effect due to the spin Hall magnetoresistance. The angular dependence of the dc voltage is theoretically analyzed by taking into account both the spin pumping and the spin rectification effects. We find that the experimental results are in excellent agreement with the theoretical model, further identifying the spin Hall magnetoresistance origin of the spin rectification effect. Moreover, the spin pumping and the spin rectification effects are quantitatively separated by their different angular dependence at particular experimental geometry.

  3. Quantum spin transistor with a Heisenberg spin chain

    Science.gov (United States)

    Marchukov, O. V.; Volosniev, A. G.; Valiente, M.; Petrosyan, D.; Zinner, N. T.

    2016-10-01

    Spin chains are paradigmatic systems for the studies of quantum phases and phase transitions, and for quantum information applications, including quantum computation and short-distance quantum communication. Here we propose and analyse a scheme for conditional state transfer in a Heisenberg XXZ spin chain which realizes a quantum spin transistor. In our scheme, the absence or presence of a control spin excitation in the central gate part of the spin chain results in either perfect transfer of an arbitrary state of a target spin between the weakly coupled input and output ports, or its complete blockade at the input port. We also discuss a possible proof-of-concept realization of the corresponding spin chain with a one-dimensional ensemble of cold atoms with strong contact interactions. Our scheme is generally applicable to various implementations of tunable spin chains, and it paves the way for the realization of integrated quantum logic elements.

  4. SPIN-selling

    CERN Document Server

    Rackham, Neil

    1995-01-01

    True or false? In selling high-value products or services: "closing" increases your chance of success; it is essential to describe the benefits of your product or service to the customer; objection handling is an important skill; and open questions are more effective than closed questions. All false, says Neil Rackham. He and his team studied more than 35,000 sales calls made by 10,000 sales people in 23 countries over 12 years. Their findings revealed that many of the methods developed for selling low-value goods just don't work for major sales. Rackham went on to introduce his SPIN-selling method, where SPIN describes the whole selling process - Situation questions, Problem questions, Implication questions, Need-payoff questions. SPIN-selling provides you with a set of simple and practical techniques which have been tried in many of today's leading companies with dramatic improvements to their sales performance.

  5. Spinning fluids reactor

    Science.gov (United States)

    Miller, Jan D; Hupka, Jan; Aranowski, Robert

    2012-11-20

    A spinning fluids reactor, includes a reactor body (24) having a circular cross-section and a fluid contactor screen (26) within the reactor body (24). The fluid contactor screen (26) having a plurality of apertures and a circular cross-section concentric with the reactor body (24) for a length thus forming an inner volume (28) bound by the fluid contactor screen (26) and an outer volume (30) bound by the reactor body (24) and the fluid contactor screen (26). A primary inlet (20) can be operatively connected to the reactor body (24) and can be configured to produce flow-through first spinning flow of a first fluid within the inner volume (28). A secondary inlet (22) can similarly be operatively connected to the reactor body (24) and can be configured to produce a second flow of a second fluid within the outer volume (30) which is optionally spinning.

  6. Perspectives on spin glasses

    CERN Document Server

    Contucci, Pierluigi

    2013-01-01

    Presenting and developing the theory of spin glasses as a prototype for complex systems, this book is a rigorous and up-to-date introduction to their properties. The book combines a mathematical description with a physical insight of spin glass models. Topics covered include the physical origins of those models and their treatment with replica theory; mathematical properties like correlation inequalities and their use in the thermodynamic limit theory; main exact solutions of the mean field models and their probabilistic structures; and the theory of the structural properties of the spin glass phase such as stochastic stability and the overlap identities. Finally, a detailed account is given of the recent numerical simulation results and properties, including overlap equivalence, ultrametricity and decay of correlations. The book is ideal for mathematical physicists and probabilists working in disordered systems.

  7. Higher-spin correlators

    CERN Document Server

    Alday, Luis F

    2013-01-01

    We analyze the properly normalized three-point correlator of two protected scalar operators and one higher spin twist-two operator in N=4 super Yang-Mills, in the limit of large spin j. The relevant structure constant can be extracted from the OPE of the four-point correlator of protected scalar operators. We show that crossing symmetry of the four point correlator plus a judicious guess for the perturbative structure of the three-point correlator, allow to make a prediction for the structure constant at all loops in perturbation theory, up to terms that remain finite as the spin becomes large. Furthermore, the expression for the structure constant allows to propose an expression for the all loops four-point correlator G(u,v), in the limit u,v -> 0. Our predictions are in perfect agreement with the large j expansion of results available in the literature.

  8. Arterial mapping of lower limbs

    International Nuclear Information System (INIS)

    A bibliographic review is realized in the arterial mapping of lower limbs by ultrasonographic. The physical properties of the Doppler effect applied to diagnostic ultrasound are described. The anatomical characteristics of the general arterial system and specifically of the lower limbs arterial system are mentioned. Pathologies of the ischemic arterial disease of lower limbs are explained. The study characteristics of lower limbs arterial mapping are documented to determine its importance as appropriate method for the assessment of lower limb ischemia. An adequate arterial mapping of lower limbs is recognized in atherosclerotic ischemic disease as a reliable initial method alternative to arteriography. Arteriography is considered as reference pattern for therapeutic decision making in patients with critical ischemia of the lower limbs. Non-invasive methods to assess the arterial system of lower limbs has evidenced the advantages of the arterial mapping with Doppler, according to the consulted literature. The combination morphological and hemodynamic information has been possible and a map of the explored zone is made. The arterial mapping by ultrasonography has offered similar reliability to angiography

  9. Exact magnetic field control of nitrogen-vacancy center spin for realizing fast quantum logic gates

    OpenAIRE

    Fang, Wen-Qi; Liu, Bang-Gui

    2015-01-01

    The negatively charged nitrogen-vacancy (NV) center spin in diamond can be used to realize quantum computation and to sense magnetic fields. Its spin triplet consists of three levels labeled with its spin z-components of +1, 0, and -1. Without external field, the +1 and -1 states are degenerate and higher than the 0 state due to the zero-field splitting. By taking the symmetrical and anti-symmetrical superpositions of the +1 and -1 states as our qubit basis, we obtain exact evolution operator...

  10. 21 CFR 610.60 - Container label.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Container label. 610.60 Section 610.60 Food and... GENERAL BIOLOGICAL PRODUCTS STANDARDS Labeling Standards § 610.60 Container label. (a) Full label. The following items shall appear on the label affixed to each container of a product capable of bearing a...

  11. Synthesis of aromatic (13)C/(2)H-α-ketoacid precursors to be used in selective phenylalanine and tyrosine protein labelling.

    Science.gov (United States)

    Lichtenecker, R J

    2014-10-14

    Recent progress in protein NMR spectroscopy revealed aromatic residues to be valuable information sources for performing structure and motion analysis of high molecular weight proteins. However, the applied NMR experiments require tailored isotope labelling patterns in order to regulate spin-relaxation pathways and optimize magnetization transfer. We introduced a methodology to use α-ketoacids as metabolic amino acid precursors in cell-based overexpression of phenylalanine and/or tyrosine labelled proteins in a recent publication, which we have now developed further by providing synthetic routes to access the corresponding side-chain labelled precursors. The target compounds allow for selective introduction of (13)C-(1)H spin systems in a highly deuterated chemical environment and feature alternating (12)C-(13)C-(12)C ring-patterns. The resulting isotope distribution is especially suited to render straightforward (13)C spin relaxation experiments possible, which provide insight into the dynamic properties of the corresponding labelled proteins.

  12. Zero-bias spin separation

    Science.gov (United States)

    Ganichev, Sergey D.; Bel'Kov, Vasily V.; Tarasenko, Sergey A.; Danilov, Sergey N.; Giglberger, Stephan; Hoffmann, Christoph; Ivchenko, Eougenious L.; Weiss, Dieter; Wegscheider, Werner; Gerl, Christian; Schuh, Dieter; Stahl, Joachim; de Boeck, Jo; Borghs, Gustaaf; Prettl, Wilhelm

    2006-09-01

    The generation, manipulation and detection of spin-polarized electrons in low-dimensional semiconductors are at the heart of spintronics. Pure spin currents, that is, fluxes of magnetization without charge current, are quite attractive in this respect. A paradigmatic example is the spin Hall effect, where an electrical current drives a transverse spin current and causes a non-equilibrium spin accumulation observed near the sample boundary. Here we provide evidence for an another effect causing spin currents which is fundamentally different from the spin Hall effect. In contrast to the spin Hall effect, it does not require an electric current to flow: without bias the spin separation is achieved by spin-dependent scattering of electrons in media with suitable symmetry. We show, by free-carrier absorption of terahertz (THz) radiation, that spin currents flow in a wide range of temperatures. Moreover, the experimental results provide evidence that simple electron gas heating by any means is already sufficient to yield spin separation due to spin-dependent energy-relaxation processes.

  13. Spin polarization of the quantum spin Hall edge states

    OpenAIRE

    Brüne, Christoph; Roth, Andreas; Buhmann, Hartmut; Hankiewicz, Ewelina M.; Molenkamp, Laurens W.; Maciejko, Joseph; Qi, Xiao-Liang; Zhang, Shou-Cheng

    2011-01-01

    While the helical character of the edge channels responsible for charge transport in the quantum spin Hall regime of a two-dimensional topological insulator is by now well established, an experimental confirmation that the transport in the edge channels is spin-polarized is still outstanding. We report experiments on nanostructures fabricated from HgTe quantum wells with an inverted band structure, in which a split gate technique allows us to combine both quantum spin Hall and metallic spin H...

  14. Spin Charge Separation in the Quantum Spin Hall State

    OpenAIRE

    Qi, Xiao-Liang; Zhang, Shou-Cheng

    2007-01-01

    The quantum spin Hall state is a topologically non-trivial insulator state protected by the time reversal symmetry. We show that such a state always leads to spin-charge separation in the presence of a $\\pi$ flux. Our result is generally valid for any interacting system. We present a proposal to experimentally observe the phenomenon of spin-charge separation in the recently discovered quantum spin Hall system.

  15. Spin Charge Separation in the Quantum Spin Hall State

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Xiao-Liang; Zhang, Shou-Cheng; /Stanford U., Phys. Dept.

    2010-03-19

    The quantum spin Hall state is a topologically non-trivial insulator state protected by the time reversal symmetry. We show that such a state always leads to spin-charge separation in the presence of a {pi} flux. Our result is generally valid for any interacting system. We present a proposal to experimentally observe the phenomenon of spin-charge separation in the recently discovered quantum spin Hall system.

  16. Spin transfer torques in nonlocal lateral spin valve

    OpenAIRE

    Xu, Yuan; Xia, Ke; Ma, Zhongshui

    2008-01-01

    We report a theoretical study on the spin and electron transport in the nonlocal lateral spin valve with non-collinear magnetic configuration. The nonlocal magnetoresistance, defined as the voltage difference on the detection lead over the injected current, is derived analytically. The spin transfer torques on the detection lead are calculated. It is found that spin transfer torques are symmetrical for parallel and antiparallel magnetic configurations, which is different from that in conventi...

  17. Electron-spin dynamics induced by photon spins

    OpenAIRE

    Ahrens, S.; Bauke, H.; Keitel, C.; Grobe, R.

    2014-01-01

    Strong rotating magnetic fields may cause a precession of the electron's spin around the rotation axis of the magnetic field. The superposition of two counterpropagating laser beams with circular polarization and opposite helicity features such a rotating magnetic field component but also carries spin. The laser's spin density, that can be expressed in terms of the lase's electromagnetic fields and potentials, couples to the electron's spin via a relativistic correction to the Pauli equation....

  18. Spin Echo in Synchrotrons

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Alexander W.; /SLAC; Courant, Ernest D.; /Brookhaven

    2006-12-01

    As a polarized beam is accelerated through a depolarization resonance, its polarization is reduced by a well-defined calculable reduction factor. When the beam subsequently crosses a second resonance, the final beam polarization is considered to be reduced by the product of the two reduction factors corresponding to the two crossings, each calculated independently of the other. This is a good approximation when the spread of spin precession frequency {Delta}{nu}{sub spin} of the beam (particularly due to its energy spread) is sufficiently large that the spin precession phases of individual particles smear out completely during the time {tau} between the two crossings. This approximate picture, however, ignores two spin dynamics effects: an interference effect and a spin echo effect. This paper is to address these two effects. The interference effect occurs when {Delta}{nu}{sub spin} is too small, or when {tau} is too short, to complete the smearing process. In this case, the two resonance crossings interfere with each other, and the final polarization exhibits constructive or destructive patterns depending on the exact value of {tau}. Typically, the beam's energy spread is large and this interference effect does not occur. To study this effect, therefore, it is necessary to reduce the beam energy spread and to consider two resonance crossings very close to each other. The other mechanism, also due to the interplay between two resonance crossings, is spin echo. It turns out that even when the precession phases appear to be completely smeared between the two crossings, there will still be a sudden and short-lived echo signal of beam polarization at a time {tau} after the second crossing; the magnitude of which can be as large as 57%. This echo signal exists even when the beam has a sizable energy spread and when {tau} is very large, and could be a sensitive (albeit challenging) way to experimentally test the intricate spin dynamics in a synchrotron. After giving

  19. Spin wave confinement

    CERN Document Server

    2008-01-01

    This book presents recent scientific achievements in the investigation of magnetization dynamics in confined magnetic systems. Introduced by Bloch as plane waves of magnetization in unconfined ferromagnets, spin waves currently play an important role in the description of very small magnetic systems ranging from microelements, which form the basis of magnetic sensors, to magnetic nano-contacts. The spin wave confinement effect was experimentally discovered in the 1990s in permalloy microstripes. The diversity of systems where this effect is observed has been steadily growing since then, and

  20. [The single coronary artery].

    Science.gov (United States)

    Godart, F; Berzin, B; Rihani, R; Pecheux, M; Dutoit, A

    1992-04-01

    Single coronary artery is a fairly rare entity which may nevertheless be found in 0.4 per cent of coronary arteriograms. The authors report 3 cases seen in 2 departments of cardiology. In each patient, despite the existence of definite cardiovascular risk factors, this distribution was a factor worsening coronary ischemia, leading to complete thrombosis in one case. Although most often a chance discovery, a review of the literature justifies the attribution to this anomaly of the onset of angina, infarction or even sudden death. PMID:1642437

  1. Patent arterial duct

    OpenAIRE

    Martin Robin P; Elmasry Ola A; Forsey Jonathan T

    2009-01-01

    Abstract Patent arterial duct (PAD) is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavi...

  2. Spin current swapping and spin hall effect in disordered metals

    Science.gov (United States)

    Saidaoui, Hamed; Pauyac, Christian; Manchon, Aurelien

    2015-03-01

    The conversion of charge currents into spin currents via the spin Hall effect has attracted intense experimental and theoretical efforts lately, providing an efficient means to generate electric signals and manipulate the magnetization of single layers. More recently, it was proposed that spin-dependent scattering induced by spin-orbit coupled impurities also produces a so-called spin swapping, i.e. an exchange between the spin angular momentum and linear momentum of itinerant electrons. In this work, we investigate the nature of spin swapping and its interplay with extrinsic spin Hall effect and spin relaxation in finite size normal metals. We use two complementary methods based on non-equilibrium Green's function technique. The first method consists in rigorously deriving the drift-diffusion equation of the spin accumulation in the presence of spin-orbit coupled impurities from quantum kinetics using Wigner expansion. The second method is the real-space tight binding modeling of a finite system in the presence of spin-orbit coupled disorder.

  3. Coherent spin mixing dynamics in thermal $^{87}$Rb spin-1 and spin-2 gases

    CERN Document Server

    He, Xiaodong; Li, Xiaoke; Wang, Fudong; Xu, Zhifang; Wang, Dajun

    2015-01-01

    We study the non-equilibrium coherent spin mixing dynamics in ferromagnetic spin-1 and antiferromagnetic spin-2 thermal gases of ultracold $^{87}$Rb atoms. Long lasting spin population oscillations with magnetic field dependent resonances are observed in both cases. Our observations are well reproduced by Boltzmann equations of the Wigner distribution function. Compared to the equation of motion of spinor Bose-Einstein condensates, the only difference here is a factor of two increase in the spin-dependent interaction, which is confirmed directly in the spin-2 case by measuring the relation between the oscillation amplitude and the sample's density.

  4. Attenuation characteristics of spin pumping signal due to travelling spin waves

    OpenAIRE

    Mukherjee, Sankha Subhra; Deorani, Praveen; Kwon, Jae Hyun; Yang, Hyunsoo

    2012-01-01

    The authors have investigated the contribution of the surface spin waves to spin pumping. A Pt/NiFe bilayer has been used for measuring spin waves and spin pumping signals simultaneously. The theoretical framework of spin pumping resulting from ferromagnetic resonance has been extended to incorporate spin pumping due to spin waves. Equations for the effective area of spin pumping due to spin waves have been derived. The amplitude of the spin pumping signal resulting from travelling waves is s...

  5. Association between internal carotid artery dissection and arterial tortuosity

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Piga, Mario [Azienda Ospedaliero Universitaria (A.O.U.), Department of Radiology, Monserrato, Cagliari (Italy); Argiolas, Giovanni Maria; Siotto, Paolo [Azienda Ospedaliero Brotzu (A.O.B.), Department of Radiology, di Cagliari (Italy); Sumer, Suna; Wintermark, Max [Neuroradiology Division, Neuroradiology, UVA Department of Radiology, Charlottesville, VA (United States); Raz, Eytan [New York University School of Medicine, Department of Radiology, New York, NY (United States); Sapienza University of Rome, Department of Neurology and Psychiatry, Rome (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria (A.O.U.), Department of Vascular Surgery, di Cagliari (Italy)

    2014-10-18

    Carotid artery dissection is an important cause of ischemic stroke in all age groups, particularly in young patients. The purpose of this work was to assess whether there is an association between the presence of an internal carotid artery dissection (ICAD) and the arterial tortuosity. This study considered 124 patients (72 males and 52 females; median age 57 years) with CT/MR diagnosis of ICAD of the internal carotid artery were considered in this multi-centric retrospective study. The arterial tortuosity was evaluated and, when present, was categorized as elongation, kinking, or coiling. For each patient, both the right and left sides were considered for a total number of 248 arteries in order to have the same number of cases and controls. Fisher's exact test was applied to test the association between elongation, kinking, coiling, dissection, and the side affected by CAD. Fisher's exact test showed a statistically significant association between the ICAD and kinking (p = 0.0089) and coiling (p = 0.0251) whereas no statistically significant difference was found with arterial vessel elongation (p = 0.444). ICAD was more often seen on the left side compared to the right (p = 0.0001). These results were confirmed using both carotid arteries of the same patient as dependent parameter with p = 0.0012, 0.0129, and 0.3323 for kinking, coiling, and elongation, respectively. The presence of kinking and coiling is associated with ICAD. (orig.)

  6. Dual anterior descending coronary artery associated with coronary artery disease

    Directory of Open Access Journals (Sweden)

    Siqueira Luciane da L. V.

    2003-01-01

    Full Text Available The patient is a male with risk factors for coronary artery disease, who was referred for cardiac catheterization after acute myocardial infarction in the inferior wall. The patient underwent transluminal coronary angioplasty in the right coronary artery with successful stent implantation.

  7. Labeled Cocaine Analogs

    Science.gov (United States)

    Goodman, Mark M.; Shi, Bing Zhi; Keil, Robert N.

    1999-01-26

    Novel compounds having the structure: ##STR1## where X in .beta. configuration is phenyl, naphthyl; 2,3 or 4-iodophenyl; 2,3 or 4-(trimethylsilyl)phenyl; 3,4,5 or 6-iodonaphthyl; 3,4,5 or 6-(trimethylsilyl)naphthyl; 2,3 or 4-(trialkylstannyl)phenyl; or 3,4,5 or 6-(trialkylstannyl)naphthyl Y in .beta. configuration is Y.sub.1 or Y.sub.2, where Y.sub.1 is 2-fluoroethoxy, 3-fluoropropoxy, 4-fluorobutoxy, 2-fluorocyclopropoxy, 2 or 3-fluorocyclobutoxy, R,S 1'-fluoroisopropoxy, R 1'-fluoroisopropoxy, S 1'-fluoroisopropoxy, 1',3'-difluoroisopropoxy, R,S 1'-fluoroisobutoxy, R 1'-fluoroisobutoxy, S 1'-fluoroisobutoxy, R,S 4'-fluoroisobutoxy, R 4'-fluoroisobutoxy, S 4'-fluoroisobutoxy, or 1',1'-di(fluoromethyl)isobutoxy, and Y.sub.2 is 2-methanesulfonyloxy ethoxy, 3-methanesulfonyloxy propoxy, 4-methanesulfonyloxy butoxy, 2-methanesulfonyloxy cyclopropoxy, 2 or 3-methanesulfonyloxy cyclobutoxy, 1'methanesulfonyloxy isopropoxy, 1'-fluoro, 3'-methanesulfonyloxy isopropoxy, 1'-methanesulfonyloxy, 3'-fluoro isopropoxy, 1'-methanesulfonyloxy isobutoxy, or 4'-methanesulfonyloxy isobutoxy bind dopamine transporter protein and can be labeled with .sup.18 F or .sup.123 I for imaging.

  8. Transverse Spin Physics: Recent Developments

    OpenAIRE

    Yuan, Feng

    2009-01-01

    Transverse-spin physics has been very active and rapidly developing in the last few years. In this talk, I will briefly summarize recent theoretical developments, focusing on the associated QCD dynamics in transverse spin physics.

  9. Polariton condensates: Electrical spin switching

    Science.gov (United States)

    Liew, T. C. H.

    2016-10-01

    Ultra-low-power electronic switching of stable exciton-polariton spin states has now been achieved in a semiconductor microcavity. This opens a new route to the integration of spin-based photonics and electronics.

  10. Bilateral Internal Thoracic Artery Configuration for Coronary Artery Bypass Surgery

    Science.gov (United States)

    Boodhwani, Munir; Hanet, Claude; de Kerchove, Laurent; Navarra, Emiliano; Astarci, Parla; Noirhomme, Philippe; El Khoury, Gebrine

    2016-01-01

    Background— Bilateral internal thoracic arteries (BITA) have demonstrated superior patency and improved survival in patients undergoing coronary artery bypass grafting. However, the optimal configuration for BITA utilization and its effect on long-term outcome remains uncertain. Methods and Results— We randomly assigned 304 patients undergoing coronary artery bypass grafting using BITA to either in situ or Y grafting configurations. The primary end point was 3-year angiographic patency. Secondary end points included major adverse cardiac and cerebrovascular events (ie, death from any cause, stroke, myocardial infarction, or repeat revascularization) at 7 years. More coronary targets were able to be revascularized using internal thoracic arteries in patients randomized to Y grafting versus in situ group (3.2±0.8 versus 2.4±0.5 arteries/patient; PURL: http://www.clinicaltrials.gov. Unique identifier: NCT01666366. PMID:27406988

  11. True arterial system compliance estimated from apparent arterial compliance.

    Science.gov (United States)

    Quick, C M; Berger, D S; Hettrick, D A; Noordergraaf, A

    2000-03-01

    A new method has been developed to estimate total arterial compliance from measured input pressure and flow. In contrast to other methods, this method does not rely on fitting the elements of a lumped model to measured data. Instead, it relies on measured input impedance and peripheral resistance to calculate the relationship of arterial blood volume to input pressure. Generally, this transfer function is a complex function of frequency and is called the apparent arterial compliance. At very low frequencies, the confounding effect of pulse wave reflection disappears, and apparent compliance becomes total arterial compliance. This study reveals that frequency components of pressure and flow below heart rate are generally necessary to obtain a valid estimate of compliance. Thus, the ubiquitous practice of estimating total arterial compliance from a single cardiac cycle is suspect under most circumstances, since a single cardiac cycle does not contain these frequencies. PMID:10784093

  12. Genetics Home Reference: pulmonary arterial hypertension

    Science.gov (United States)

    ... Home Health Conditions pulmonary arterial hypertension pulmonary arterial hypertension Enable Javascript to view the expand/collapse boxes. ... All Open All Close All Description Pulmonary arterial hypertension is a progressive disorder characterized by abnormally high ...

  13. Perturbation of nuclear spin polarizations in solid state NMR of nitroxide-doped samples by magic-angle spinning without microwaves

    Science.gov (United States)

    Thurber, Kent R.; Tycko, Robert

    2014-05-01

    We report solid state 13C and 1H nuclear magnetic resonance (NMR) experiments with magic-angle spinning (MAS) on frozen solutions containing nitroxide-based paramagnetic dopants that indicate significant perturbations of nuclear spin polarizations without microwave irradiation. At temperatures near 25 K, 1H and cross-polarized 13C NMR signals from 15N,13C-labeled L-alanine in trinitroxide-doped glycerol/water are reduced by factors as large as six compared to signals from samples without nitroxide doping. Without MAS or at temperatures near 100 K, differences between signals with and without nitroxide doping are much smaller. We attribute most of the reduction of NMR signals under MAS near 25 K to nuclear spin depolarization through the cross-effect dynamic nuclear polarization mechanism, in which three-spin flips drive nuclear polarizations toward equilibrium with spin polarization differences between electron pairs. When T1e is sufficiently long relative to the MAS rotation period, the distribution of electron spin polarization across the nitroxide electron paramagnetic resonance lineshape can be very different from the corresponding distribution in a static sample at thermal equilibrium, leading to the observed effects. We describe three-spin and 3000-spin calculations that qualitatively reproduce the experimental observations.

  14. Perturbation of nuclear spin polarizations in solid state NMR of nitroxide-doped samples by magic-angle spinning without microwaves

    Energy Technology Data Exchange (ETDEWEB)

    Thurber, Kent R., E-mail: thurberk@niddk.nih.gov; Tycko, Robert [Laboratory of Chemical Physics, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, Maryland 20892-0520 (United States)

    2014-05-14

    We report solid state {sup 13}C and {sup 1}H nuclear magnetic resonance (NMR) experiments with magic-angle spinning (MAS) on frozen solutions containing nitroxide-based paramagnetic dopants that indicate significant perturbations of nuclear spin polarizations without microwave irradiation. At temperatures near 25 K, {sup 1}H and cross-polarized {sup 13}C NMR signals from {sup 15}N,{sup 13}C-labeled L-alanine in trinitroxide-doped glycerol/water are reduced by factors as large as six compared to signals from samples without nitroxide doping. Without MAS or at temperatures near 100 K, differences between signals with and without nitroxide doping are much smaller. We attribute most of the reduction of NMR signals under MAS near 25 K to nuclear spin depolarization through the cross-effect dynamic nuclear polarization mechanism, in which three-spin flips drive nuclear polarizations toward equilibrium with spin polarization differences between electron pairs. When T{sub 1e} is sufficiently long relative to the MAS rotation period, the distribution of electron spin polarization across the nitroxide electron paramagnetic resonance lineshape can be very different from the corresponding distribution in a static sample at thermal equilibrium, leading to the observed effects. We describe three-spin and 3000-spin calculations that qualitatively reproduce the experimental observations.

  15. Perturbation of nuclear spin polarizations in solid state NMR of nitroxide-doped samples by magic-angle spinning without microwaves

    International Nuclear Information System (INIS)

    We report solid state 13C and 1H nuclear magnetic resonance (NMR) experiments with magic-angle spinning (MAS) on frozen solutions containing nitroxide-based paramagnetic dopants that indicate significant perturbations of nuclear spin polarizations without microwave irradiation. At temperatures near 25 K, 1H and cross-polarized 13C NMR signals from 15N,13C-labeled L-alanine in trinitroxide-doped glycerol/water are reduced by factors as large as six compared to signals from samples without nitroxide doping. Without MAS or at temperatures near 100 K, differences between signals with and without nitroxide doping are much smaller. We attribute most of the reduction of NMR signals under MAS near 25 K to nuclear spin depolarization through the cross-effect dynamic nuclear polarization mechanism, in which three-spin flips drive nuclear polarizations toward equilibrium with spin polarization differences between electron pairs. When T1e is sufficiently long relative to the MAS rotation period, the distribution of electron spin polarization across the nitroxide electron paramagnetic resonance lineshape can be very different from the corresponding distribution in a static sample at thermal equilibrium, leading to the observed effects. We describe three-spin and 3000-spin calculations that qualitatively reproduce the experimental observations

  16. How to Read a Nutrition Facts Label

    Medline Plus

    Full Text Available ... Under Control Figuring Out Food Labels Healthy Food Shopping If My Child Has Food Allergies, What Should ... for Parents Figuring Out Food Labels Smart Supermarket Shopping Figuring Out Fat and Calories Food Labels Contact ...

  17. Layered kagome spin ice

    Science.gov (United States)

    Hamp, James; Dutton, Sian; Mourigal, Martin; Mukherjee, Paromita; Paddison, Joseph; Ong, Harapan; Castelnovo, Claudio

    Spin ice materials provide a rare instance of emergent gauge symmetry and fractionalisation in three dimensions: the effective degrees of freedom of the system are emergent magnetic monopoles, and the extensively many `ice rule' ground states are those devoid of monopole excitations. Two-dimensional (kagome) analogues of spin ice have also been shown to display a similarly rich behaviour. In kagome ice however the ground-state `ice rule' condition implies the presence everywhere of magnetic charges. As temperature is lowered, an Ising transition occurs to a charge-ordered state, which can be mapped to a dimer covering of the dual honeycomb lattice. A second transition, of Kosterlitz-Thouless or three-state Potts type, occurs to a spin-ordered state at yet lower temperatures, due to small residual energy differences between charge-ordered states. Inspired by recent experimental capabilities in growing spin ice samples with selective (layered) substitution of non-magnetic ions, in this work we investigate the fate of the two ordering transitions when individual kagome layers are brought together to form a three-dimensional pyrochlore structure coupled by long range dipolar interactions. We also consider the response to substitutional disorder and applied magnetic fields.

  18. Brookhaven: Spin result underlined

    International Nuclear Information System (INIS)

    A recent experiment looking at violent proton-proton elastic scattering confirms, with high precision, earlier data which puzzled many theorists. Most pictures of strong interactions based on perturbative quark-gluon field theory (Quantum Chromodynamics, QCD) suggested that spin effects should disappear with energy and as the collisions become more violent

  19. Antiferromagnetic spin-orbitronics

    KAUST Repository

    Manchon, Aurelien

    2015-05-01

    Antiferromagnets have long remained an intriguing and exotic state of matter, whose application has been restricted to enabling interfacial exchange bias in metallic and tunneling spin-valves [1]. Their role in the expanding field of applied spintronics has been mostly passive and the in-depth investigation of their basic properties mostly considered from a fundamental perspective.

  20. TRANSVERSITY SINGLE SPIN ASYMMETRIES.

    Energy Technology Data Exchange (ETDEWEB)

    BOER,D.

    2001-04-27

    The theoretical aspects of two leading twist transversity single spin asymmetries, one arising from the Collins effect and one from the interference fragmentation functions, are reviewed. Issues of factorization, evolution and Sudakov factors for the relevant observables are discussed. These theoretical considerations pinpoint the most realistic scenarios towards measurements of transversity.