WorldWideScience

Sample records for arterial spin labeling

  1. Myocardial arterial spin labeling

    OpenAIRE

    Kober, Frank; Jao, Terrence; Troalen, Thomas; Nayak, Krishna S.

    2016-01-01

    Arterial spin labeling (ASL) is a cardiovascular magnetic resonance (CMR) technique for mapping regional myocardial blood flow. It does not require any contrast agents, is compatible with stress testing, and can be performed repeatedly or even continuously. ASL-CMR has been performed with great success in small-animals, but sensitivity to date has been poor in large animals and humans and remains an active area of research. This review paper summarizes the development of ASL-CMR techniques, c...

  2. Superselective pseudo-continuous arterial spin labeling angiography

    International Nuclear Information System (INIS)

    Highlights: • Superselective arterial spin labeling was capable of acquiring angiograms of individually selected arteries. • Image quality was similar compared with a routinely used time-of-flight angiography. • Superselective arterial spin labeling was utilized in patients with arterio-venous malformations and made it possible to visualize individual feeding vessels in a complete non-invasive way - Abstract: Purpose: To evaluate the utility of a novel non-contrast enhanced, vessel-selective magnetic resonance angiography (MRA) approach based on superselective pseudo-continuous arterial spin labeling (ASL) for the morphologic assessment of intracranial arteries when compared to a clinically used time-of-flight (TOF) MRA. Materials and methods: Three sets of selective ASL angiographies (right and left internal carotid artery, basilar artery) as well as one TOF data set were obtained from each of the five volunteers included in this study on a clinical 1.5T system. The depiction of arterial segments as well as their delineation was evaluated and independently analyzed by two radiologists. Additionally, the ASL angiography approach was performed in two patients suffering from arterio-venous malformations (AVM) in order to illustrate potential applications in a clinical setting. Results: In both angiography techniques, intracranial arteries and their segments (distal branches up to A5 segments of the anterior cerebral arteries, M8 segments of the middle cerebral arteries, and P5 segments of the posterior cerebral arteries) were continuously depicted with excellent inter-reader agreement (κ > 0.81). In AVM patients, reconstructed images of the TOF angiography presented similar information about the size and shape of the AVM as did superselective ASL angiography. In addition, the acquired ASL angiograms of selected vessels allowed assessing the blood supply of individually labeled arteries to the AVM which could also be confirmed by digital subtraction angiography

  3. Superselective pseudo-continuous arterial spin labeling angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jensen-Kondering, Ulf [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Lindner, Thomas, E-mail: thomas.lindner@uksh.de [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Osch, Matthias J.P. van [C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden (Netherlands); Rohr, Axel; Jansen, Olav [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Helle, Michael [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Now with Philips GmbH Innovative Technologies, Research Laboratories, Hamburg (Germany)

    2015-09-15

    Highlights: • Superselective arterial spin labeling was capable of acquiring angiograms of individually selected arteries. • Image quality was similar compared with a routinely used time-of-flight angiography. • Superselective arterial spin labeling was utilized in patients with arterio-venous malformations and made it possible to visualize individual feeding vessels in a complete non-invasive way - Abstract: Purpose: To evaluate the utility of a novel non-contrast enhanced, vessel-selective magnetic resonance angiography (MRA) approach based on superselective pseudo-continuous arterial spin labeling (ASL) for the morphologic assessment of intracranial arteries when compared to a clinically used time-of-flight (TOF) MRA. Materials and methods: Three sets of selective ASL angiographies (right and left internal carotid artery, basilar artery) as well as one TOF data set were obtained from each of the five volunteers included in this study on a clinical 1.5T system. The depiction of arterial segments as well as their delineation was evaluated and independently analyzed by two radiologists. Additionally, the ASL angiography approach was performed in two patients suffering from arterio-venous malformations (AVM) in order to illustrate potential applications in a clinical setting. Results: In both angiography techniques, intracranial arteries and their segments (distal branches up to A5 segments of the anterior cerebral arteries, M8 segments of the middle cerebral arteries, and P5 segments of the posterior cerebral arteries) were continuously depicted with excellent inter-reader agreement (κ > 0.81). In AVM patients, reconstructed images of the TOF angiography presented similar information about the size and shape of the AVM as did superselective ASL angiography. In addition, the acquired ASL angiograms of selected vessels allowed assessing the blood supply of individually labeled arteries to the AVM which could also be confirmed by digital subtraction angiography

  4. Background suppression in arterial spin labeling MRI with a separate neck labeling coil

    OpenAIRE

    Shen, Qiang; Duong, Timothy Q.

    2011-01-01

    In arterial spin labeling (ASL) MRI to measure cerebral blood flow (CBF), pair-wise subtraction of temporally adjacent non-labeled and labeled images often can not completely cancel the background static tissue signal because of temporally fluctuating physiological noise. While background suppression (BS) by inversion nulling improves CBF temporal stability, imperfect pulses compromise CBF contrast. Conventional BS techniques may not be applicable in small animals because the arterial transit...

  5. Modelling the effects of cardiac pulsations in arterial spin labelling

    International Nuclear Information System (INIS)

    It has recently been demonstrated experimentally that cardiac pulsations seem significantly to affect the arterial spin labelling (ASL) signal. In this paper, we introduce a new theoretical model to examine this effect. Existing models of ASL do not take such effects into account since they model the transit of the ASL signal assuming uniform plug flow with a single transit delay. In this study, we model cardiac pulsations through the coupling of the Navier-Stokes equations with the three-dimensional mass transport equation. Our results complement the experimental findings and suggest that the ASL signal does depend on the timing of the onset of the cardiac cycle relative to the tagging and imaging locations. However, cardiac pulsatility only appears to have a small effect on the quantification of perfusion estimates.

  6. Diagnostic Potential of Pulsed Arterial Spin Labeling in Alzheimer's Disease

    Science.gov (United States)

    Trebeschi, Stefano; Riederer, Isabelle; Preibisch, Christine; Bohn, Karl P.; Förster, Stefan; Alexopoulos, Panagiotis; Zimmer, Claus; Kirschke, Jan S.; Valentinitsch, Alexander

    2016-01-01

    Alzheimers disease (AD) is the most common cause of dementia. Although the underlying pathology is still not completely understood, several diagnostic methods are available. Frequently, the most accurate methods are also the most invasive. The present work investigates the diagnostic potential of Pulsed Arterial Spin Labeling (PASL) for AD: a non-invasive, MRI-based technique for the quantification of regional cerebral blood flow (rCBF). In particular, we propose a pilot computer aided diagnostic (CAD) procedure able to discriminate between healthy and diseased subjects, and at the same time, providing visual informative results. This method encompasses the creation of a healthy model, the computation of a voxel-wise likelihood function as comparison between the healthy model and the subject under examination, and the correction of the likelihood function via prior distributions. The discriminant analysis is carried out to maximize the accuracy of the classification. The algorithm has been trained on a dataset of 81 subjects and achieved a sensitivity of 0.750 and a specificity of 0.875. Moreover, in accordance with the current pathological knowledge, the parietal lobe, and limbic system are shown to be the main discriminant factors. PMID:27147946

  7. Arterial spin-labeling MR imaging of cerebral hemorrhages

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Tomoyuki [Department of Radiology, National Center for Global Health and Medicine, Tokyo (Japan); Saga University, Department of Radiology, Faculty of Medicine and Graduate School of Medicine, Saga (Japan); Nishihara, Masashi; Egashira, Yoshiaki; Azama, Shinya; Hirai, Tetsuyoshi; Kitano, Isao; Irie, Hiroyuki [Saga University, Department of Radiology, Faculty of Medicine and Graduate School of Medicine, Saga (Japan); Yakushiji, Yusuke [Saga University, Department of Neurology, Faculty of Medicine and Graduate School of Medicine, Saga (Japan); Kawashima, Masatou [Saga University, Department of Neurosurgery, Faculty of Medicine and Graduate School of Medicine, Saga (Japan)

    2015-11-15

    The purpose of this study is to identify the characteristics of brain perfusion measured by arterial spin-labeling magnetic resonance imaging (ASL-MRI) in cerebral hemorrhages. Brain blood flow values (CBF-ASL values) for cerebral and cerebellar hemispheres and segmented cerebral regions were measured by ASL-MRI in 19 putaminal hemorrhage patients and 20 thalamic hemorrhage patients in acute or subacute stages. We assessed the lateralities of CBF-ASL values and the relationships between CBF-ASL values and other imaging findings and clinical manifestations. Both the 19 putaminal hemorrhage patients and the 20 thalamic hemorrhage patients had significantly low CBF-ASL values of the contralateral cerebellum in subacute stage, suggesting that ASL-MRI might delineate crossed cerebellar diaschisis (CCD). Ipsilateral low CBF-ASL values were observed in frontal lobes and thalami with a putaminal hemorrhage and lentiform nuclei, temporal lobes, and parietal lobes with a thalamic hemorrhage, suggesting that ASL-MRI showed the ipsilateral cerebral diaschisis (ICD). In the putaminal hemorrhage patients, the hematoma volume negatively affected both the bilateral cerebellar and cerebral hemispheric CBF-ASL values. In the thalamic hemorrhage patients, a concomitant intraventricular hemorrhage caused low cerebral hemispheric CBF-ASL values. The use of ASL-MRI is sensitive to the perfusion abnormalities and could thus be helpful to estimate functional abnormalities in cerebral hemorrhage patients. (orig.)

  8. Nonlinear magnetic field gradients can reduce SAR in flow-driven arterial spin labeling measurements

    Science.gov (United States)

    Marro, Kenneth I.; Lee, Donghoon; Hyyti, Outi M.

    2007-03-01

    This work describes how custom-built gradient coils, designed to generate magnetic fields with amplitudes that vary nonlinearly with position, can be used to reduce the potential for unsafe tissue heating during flow-driven arterial spin labeling processes. A model was developed to allow detailed analysis of the adiabatic excitation process used for flow-driven arterial water stimulation with elimination of tissue signal (FAWSETS) an arterial spin labeling method developed specifically for use in skeletal muscle. The model predicted that, by adjusting the amplitude of the gradient field, the specific absorption rate could be reduced by more than a factor of 6 while still achieving effective labeling. Flow phantom measurements and in vivo measurements from exercising rat hind limb confirmed the accuracy of the model's predictions. The modeling tools were also applied to the more widely used continuous arterial spin labeling (CASL) method and predicted that specially shaped gradients could allow similar reductions in SAR.

  9. Arterial spin labeling perfusion MRI: Inter-vendor reproducibility and clinical applicability

    NARCIS (Netherlands)

    H.J.M.M. Mutsaerts

    2015-01-01

    Arterial spin labeling (ASL) is a perfusion magnetic resonance imaging (MRI) technique that non-invasively measures cerebral blood flow (CBF). The first part of this thesis concerns the inter-vendor reproducibility of ASL. Studies in this thesis show that on a total gray matter (GM) level, long-term

  10. Arterial and portal venous liver perfusion using selective spin labelling MRI

    Energy Technology Data Exchange (ETDEWEB)

    Schalkx, Hanke J.; Petersen, Esben T.; Veldhuis, Wouter B.; Leeuwen, Maarten S. van; Bosch, Maurice A.A.J. van den [University Medical Center Utrecht, Department of Radiology, HP E.01.132, Postbus 85500, Utrecht (Netherlands); Peters, Nicky H.G.M. [Atrium Medical Center Parkstad, Department of Radiology, Heerlen (Netherlands); Pluim, Josien P.W.; Stralen, Marijn van [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands)

    2015-06-01

    To investigate the feasibility of selective arterial and portal venous liver perfusion imaging with spin labelling (SL) MRI, allowing separate labelling of each blood supply. The portal venous perfusion was assessed with a pulsed EPISTAR technique and the arterial perfusion with a pseudo-continuous sequence. To explore precision and reproducibility, portal venous and arterial perfusion were separately quantified in 12 healthy volunteers pre- and postprandially (before and after meal intake). In a subgroup of 6 volunteers, the accuracy of the absolute portal perfusion and its relative postprandial change were compared with MRI flow measurements of the portal vein. The portal venous perfusion significantly increased from 63 ± 22 ml/100g/min preprandially to 132 ± 42 ml/100g/min postprandially. The arterial perfusion was lower with 35 ± 22 preprandially and 22 ± 30 ml/100g/min postprandially. The pre- and postprandial portal perfusion using SL correlated well with flow-based perfusion (r{sup 2} = 0.71). Moreover, postprandial perfusion change correlated well between SL- and flow-based quantification (r{sup 2} = 0.77). The SL results are in range with literature values. Selective spin labelling MRI of the portal venous and arterial blood supply successfully quantified liver perfusion. This non-invasive technique provides specific arterial and portal venous perfusion imaging and could benefit clinical settings where contrast agents are contraindicated. (orig.)

  11. Strategies for Reducing Respiratory Motion Artifacts in Renal Perfusion Imaging with Arterial Spin Labeling

    OpenAIRE

    Robson, Philip M.; Madhuranthakam, Ananth J.; Dai, Weiying; Pedrosa, Ivan; Rofsky, Neil M.; Alsop, David C.

    2009-01-01

    Arterial Spin Labeling (ASL) perfusion measurements may have many applications outside the brain. In the abdomen, severe image-artifacts can arise from motions between acquisitions of multiple signal averages in ASL, even with single-shot image-acquisition. Background suppression and respiratory motion synchronization techniques can be used to ameliorate these artifacts. Two separate in-vivo studies of renal perfusion imaging using pulsed-continuous ASL were performed. The first study assesse...

  12. Hyperemic flow heterogeneity within the calf, foot, and forearm measured with continuous arterial spin labeling MRI

    OpenAIRE

    Wu, Wen-Chau; Wang, Jiongjiong; Detre, John A.; Wehrli, Felix W.; Mohler, Emile; Ratcliffe, Sarah J.; Floyd, Thomas F

    2008-01-01

    Arterial spin labeling (ASL) is a noninvasive magnetic resonance imaging (MRI) technique for microvascular blood flow measurement. We used a continuous ASL scheme (CASL) to investigate the hyperemic flow difference between major muscle groups in human extremities. Twenty-four healthy subjects with no evidence of vascular disease were recruited. MRI was conducted on a 3.0 Tesla Siemens Trio whole body system with a transmit/receive knee coil. A nonmagnetic orthopedic tourniquet system was used...

  13. Diagnostic significance of arterial spin labeling in the assessment of tumor grade in brain

    OpenAIRE

    Yu-Fang Wang; Bo Hou; Su-Jun Yang; Xiao-Rui Zhang; Xiaolei Dong; Min Zhang; Gen-Dong Yao

    2016-01-01

    Background: The objective of the current meta.analysis was to assess the arterial spin labeling. (ASL) perfusion imaging measurement of cerebral blood flow. (CBF) in patients with brain tumors, and assessing preoperative tumor grade in brain. Materials and Methods: PubMed, Web of Science, Embase, China BioMedicine (CBM), CINAHL, Cochrane Library, and China National Knowledge Infrastructure (CNKI) databases were chosen to evaluate the associations between ASL and brain cancer. Two reviewers...

  14. Cerebral Perfusion Measurements in Elderly with Hypertension Using Arterial Spin Labeling

    DEFF Research Database (Denmark)

    Mutsaerts, H J M M; van Dalen, J W; Heijtel, D F R;

    2015-01-01

    PURPOSE: The current study assesses the feasibility and value of crushed cerebral blood flow (CBFcrushed) and arterial transit time (ATT) estimations for large clinical imaging studies in elderly with hypertension. MATERIAL AND METHODS: Two pseudo-continuous arterial spin labeling (ASL) scans with...... (CBFcrushed) and without flow crushers (CBFnon-crushed) were performed in 186 elderly with hypertension, from which CBF and ATT maps were calculated. Standard flow territory maps were subdivided into proximal, intermediate and distal flow territories, based on the measured ATT. The coefficient of variation...... group analyses in elderly with hypertension. The obtained flow territories provide knowledge on vascular anatomy of elderly with hypertension and can be used in future studies to investigate regional vascular effects....

  15. Measurement of vascular water transport in human subjects using time-resolved pulsed arterial spin labelling.

    Science.gov (United States)

    Bibic, Adnan; Knutsson, Linda; Schmidt, Anders; Henningsson, Erik; Månsson, Sven; Abul-Kasim, Kasim; Åkeson, Jonas; Gunther, Matthias; Ståhlberg, Freddy; Wirestam, Ronnie

    2015-08-01

    Most approaches to arterial spin labelling (ASL) data analysis aim to provide a quantitative measure of the cerebral blood flow (CBF). This study, however, focuses on the measurement of the transfer time of blood water through the capillaries to the parenchyma (referred to as the capillary transfer time, CTT) as an alternative parameter to characterise the haemodynamics of the system. The method employed is based on a non-compartmental model, and no measurements need to be added to a common time-resolved ASL experiment. Brownian motion of labelled spins in a potential was described by a one-dimensional general Langevin equation as the starting point, and as a Fokker-Planck differential equation for the averaged distribution of labelled spins at the end point, which takes into account the effects of flow and dispersion of labelled water by the pseudorandom nature of the microvasculature and the transcapillary permeability. Multi-inversion time (multi-TI) ASL data were acquired in 14 healthy subjects on two occasions in a test-retest design, using a pulsed ASL sequence and three-dimensional gradient and spin echo (3D-GRASE) readout. Based on an error analysis to predict the size of a region of interest (ROI) required to obtain reasonably precise parameter estimates, data were analysed in two relatively large ROIs, i.e. the occipital lobe (OC) and the insular cortex (IC). The average values of CTT in OC were 260 ± 60 ms in the first experiment and 270 ± 60 ms in the second experiment. The corresponding IC values were 460 ± 130 ms and 420 ± 139 ms, respectively. Information related to the water transfer time may be important for diagnostics and follow-up of cerebral conditions or diseases characterised by a disrupted blood-brain barrier or disturbed capillary blood flow. PMID:26147641

  16. Implementation of quantitative perfusion imaging using pulsed arterial spin labeling at ultra-high field.

    Science.gov (United States)

    Gardener, A G; Gowland, P A; Francis, S T

    2009-04-01

    This study compares the implementation of the STAR and FAIR pulsed arterial spin labeling (PASL) schemes to form quantitative perfusion maps at ultra-high field, 7 Tesla (T), and high field, 3 T. Phantom experiments were performed to compare the inversion efficiency and profile of the labeling pulses at 7 T and 3 T and to optimize in-plane saturation techniques. The perfusion weighted (PW) signal was measured at a range of postlabeling delay times and quantitative perfusion maps were calculated on a voxel-by-voxel basis. An increase in PW signal was found with field strength, and together with the increased signal-to-noise ratio, this led to improved image signal-to-noise and quality of fit of perfusion maps at 7 T. PMID:19189295

  17. Reduction in cerebral perfusion after heroin administration: a resting state arterial spin labeling study.

    Directory of Open Access Journals (Sweden)

    Niklaus Denier

    Full Text Available Heroin dependence is a chronic relapsing brain disorder, characterized by the compulsion to seek and use heroin. Heroin itself has a strong potential to produce subjective experiences characterized by intense euphoria, relaxation and release from craving. The neurofunctional foundations of these perceived effects are not well known. In this study, we have used pharmacological magnetic resonance imaging (phMRI in 15 heroin-dependent patients from a stable heroin-assisted treatment program to observe the steady state effects of heroin (60 min after administration. Patients were scanned in a cross-over and placebo controlled design. They received an injection of their regular dose of heroin or saline (placebo before or after the scan. As phMRI method, we used a pulsed arterial spin labeling (ASL sequence based on a flow-sensitive alternating inversion recovery (FAIR spin labeling scheme combined with a single-shot 3D GRASE (gradient-spin echo readout on a 3 Tesla scanner. Analysis was performed with Statistical Parametric Mapping (SPM 8, using a general linear model for whole brain comparison between the heroin and placebo conditions. We found that compared to placebo, heroin was associated with reduced perfusion in the left anterior cingulate cortex (ACC, the left medial prefrontal cortex (mPFC and in the insula (both hemispheres. Analysis of extracted perfusion values indicate strong effect sizes and no gender related differences. Reduced perfusion in these brain areas may indicate self- and emotional regulation effects of heroin in maintenance treatment.

  18. Arterial spin labeling in patients with chic cerebral artery steno-occlusive disease - Correlation with 15O-PET

    International Nuclear Information System (INIS)

    Background: Heterogeneity of arterial transit time due to cerebral artery steno-occlusive lesions hampers accurate regional cerebral blood flow measurement by arterial spin labeling (ASL). Purpose: To assess the feasibility of regional cerebral blood flow measurement by ASL with multiple-delay time sampling in patients with steno-occlusive diseases by comparing with positron emission tomography (PET), and to determine whether regional arterial transit time measured by this ASL technique is correlated with regional mean transit time, a PET index of perfusion pressure. Material and Methods: Sixteen patients with steno-occlusive diseases received both ASL and 15O-PET. The mean regional cerebral blood flow measured by ASL and PET, regional arterial transit time by ASL, and regional mean transit time by PET were obtained by a region-of-interest analysis. Correlation between regional cerebral blood flow by ASL and that by PET, and correlation between regional arterial transit time by ASL and regional mean transit time by PET were tested using Pearson's correlation coefficient for both absolute and relative values. A multivariate regression analysis was performed to test whether regional arterial transit time by ASL was a significant contributor in modeling regional mean transit time by PET after controlling the effect of regional cerebral blood flow by ASL. Results: A significant positive correlation was found between regional cerebral blood flow by ASL and that by PET for both absolute (r = 0.520, P < 0.0001) and relative (r = 0.691, P < 0.0001) values. A significant positive correlation was found between regional arterial transit time by ASL and regional mean transit time by PET both for absolute (r = 0.369, P = 0.0002) and relative (r = 0.443, P < 0.0001) values. The regression analysis revealed that regional arterial transit time by ASL was a significant contributor in modeling regional mean transit time by PET after controlling regional cerebral blood flow by ASL (P

  19. Improving perfusion quantification in arterial spin labeling for delayed arrival times by using optimized acquisition schemes

    Energy Technology Data Exchange (ETDEWEB)

    Kramme, Johanna [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); Univ. Bremen (Germany). Faculty of Physics and Electronics; Gregori, Johannes [mediri GmbH, Heidelberg (Germany); Diehl, Volker [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); ZEMODI (Zentrum fuer morderne Diagnostik), Bremen (Germany); Madai, Vince I.; Sobesky, Jan [Charite-Universitaetsmedizin Berlin (Germany). Center for Stroke Research Berlin (CSB); Charite-Universitaetsmedizin Berlin (Germany). Dept. of Neurology; Samson-Himmelstjerna, Frederico C. von [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); Charite-Universitaetsmedizin Berlin (Germany). Center for Stroke Research Berlin (CSB); Charite-Universitaetsmedizin Berlin (Germany). Dept. of Neurology; Lentschig, Markus [ZEMODI (Zentrum fuer morderne Diagnostik), Bremen (Germany); Guenther, Matthias [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); Univ. Bremen (Germany). Faculty of Physics and Electronics; mediri GmbH, Heidelberg (Germany)

    2015-07-01

    The improvement in Arterial Spin Labeling (ASL) perfusion quantification, especially for delayed bolus arrival times (BAT), with an acquisition redistribution scheme mitigating the T1 decay of the label in multi-TI ASL measurements is investigated. A multi inflow time (TI) 3D-GRASE sequence is presented which adapts the distribution of acquisitions accordingly, by keeping the scan time constant. The MR sequence increases the number of averages at long TIs and decreases their number at short TIs and thus compensating the T1 decay of the label. The improvement of perfusion quantification is evaluated in simulations as well as in-vivo in healthy volunteers and patients with prolonged BATs due to age or steno-occlusive disease. The improvement in perfusion quantification depends on BAT. At healthy BATs the differences are small, but become larger for longer BATs typically found in certain diseases. The relative error of perfusion is improved up to 30% at BATs > 1500 ms in comparison to the standard acquisition scheme. This adapted acquisition scheme improves the perfusion measurement in comparison to standard multi-TI ASL implementations. It provides relevant benefit in clinical conditions that cause prolonged BATs and is therefore of high clinical relevance for neuroimaging of steno-occlusive diseases.

  20. The QUASAR reproducibility study, Part II: Results from a multi center Arterial Spin Labeling test-retest Study

    OpenAIRE

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier

    2009-01-01

    Arterial Spin Labeling (ASL) is a method to measure perfusion using magnetically labeled blood water as an endogenous tracer. Being fully non-invasive, this technique is attractive for longitudinal studies of cerebral blood flow in healthy and diseased individuals, or as a surrogate marker of metabolism. So far, ASL has been restricted mostly to specialist centers due to a generally low SNR of the method and potential issues with user-dependent analysis needed to obtain quantitative measureme...

  1. Assesment of perfusion in glial tumors with arterial spin labeling; comparison with dynamic susceptibility contrast method

    Energy Technology Data Exchange (ETDEWEB)

    Cebeci, H, E-mail: hcebeci16@gmail.com [Department of Radiology, Uludag University Medical School, Bursa (Turkey); Aydin, O [Department of Radiology, Uludag University Medical School, Bursa (Turkey); Ozturk-Isik, E; Gumus, C [Department of Biomedical Engineering, Yeditepe University, Istanbul (Turkey); Inecikli, F [Department of Radiology, Kanuni Sultan Suleyman Educational and Research Hospital, Istanbul (Turkey); Bekar, A; Kocaeli, H [Department of Neurosurgery, Uludag University Medical School, Bursa (Turkey); Hakyemez, B [Department of Radiology, Uludag University Medical School, Bursa (Turkey)

    2014-10-15

    Highlights: • We compared the perfusion parameters obtained with both DSC and ASL perfusion imaging methods. • In ASL perfusion imaging, we also created quantitative CBF maps. • All patients included in the study had histopathological diagnose. • All MR examinations are done with 3T MR imaging system. - Abstract: Purpose: Arterial spin labeling perfusion imaging (ASL-PI) is a non-invasive perfusion imaging method that can be used for evaluation and quantification of cerebral blood flow (CBF). Aim of our study was to evaluating the efficiency of ASL in histopathological grade estimation of glial tumors and comparing findings with dynamic susceptibility contrast perfusion imaging (DSC-PI) method. Methods: This study involved 33 patients (20 high-grade and 13 low-grade gliomas). Multiphase multislice pulsed ASL MRI sequence and a first-passage gadopentetate dimeglumine T2*-weighted gradient-echo single-shot echo-planar sequence were acquired for all the patients. For each patient, perfusion relative signal intensity (rSI), CBF and relative CBF (rCBF) on ASL-PI and relative cerebral blood volume (rCBV) and relative cerebral blood flow (rCBF) values on DSC-PI were determined. The relative signal intensity of each tumor was determined as the maximal SI within the tumor divided by SI within symetric region in the contralateral hemisphere on ASL-PI. rCBV and rCBF were calculated by deconvolution of an arterial input function. Relative values of the lesions were obtained by dividing the values to the normal appearing symmetric region on the contralateral hemisphere. For statistical analysis, Mann–Whitney ranksum test was carried out. Receiver operating characteristic curve (ROC) analysis was performed to assess the relationship between the rCBF-ASL, rSI-ASL, rCBV and rCBF ratios and grade of gliomas. Their cut-off values permitting best discrimination was calculated. The correlation between rCBV, rCBF, rSI-ASL and rCBF-ASL and glioma grade was assessed using

  2. Assesment of perfusion in glial tumors with arterial spin labeling; comparison with dynamic susceptibility contrast method

    International Nuclear Information System (INIS)

    Highlights: • We compared the perfusion parameters obtained with both DSC and ASL perfusion imaging methods. • In ASL perfusion imaging, we also created quantitative CBF maps. • All patients included in the study had histopathological diagnose. • All MR examinations are done with 3T MR imaging system. - Abstract: Purpose: Arterial spin labeling perfusion imaging (ASL-PI) is a non-invasive perfusion imaging method that can be used for evaluation and quantification of cerebral blood flow (CBF). Aim of our study was to evaluating the efficiency of ASL in histopathological grade estimation of glial tumors and comparing findings with dynamic susceptibility contrast perfusion imaging (DSC-PI) method. Methods: This study involved 33 patients (20 high-grade and 13 low-grade gliomas). Multiphase multislice pulsed ASL MRI sequence and a first-passage gadopentetate dimeglumine T2*-weighted gradient-echo single-shot echo-planar sequence were acquired for all the patients. For each patient, perfusion relative signal intensity (rSI), CBF and relative CBF (rCBF) on ASL-PI and relative cerebral blood volume (rCBV) and relative cerebral blood flow (rCBF) values on DSC-PI were determined. The relative signal intensity of each tumor was determined as the maximal SI within the tumor divided by SI within symetric region in the contralateral hemisphere on ASL-PI. rCBV and rCBF were calculated by deconvolution of an arterial input function. Relative values of the lesions were obtained by dividing the values to the normal appearing symmetric region on the contralateral hemisphere. For statistical analysis, Mann–Whitney ranksum test was carried out. Receiver operating characteristic curve (ROC) analysis was performed to assess the relationship between the rCBF-ASL, rSI-ASL, rCBV and rCBF ratios and grade of gliomas. Their cut-off values permitting best discrimination was calculated. The correlation between rCBV, rCBF, rSI-ASL and rCBF-ASL and glioma grade was assessed using

  3. Demonstration of pulmonary perfusion heterogeneity induced by gravity and lung inflation using arterial spin labeling

    International Nuclear Information System (INIS)

    Objective: To evaluate the effect of gravity and lung inflation on pulmonary perfusion heterogeneity in human lung using an arterial spin labeling (ASL) sequence called flow sensitive alternating inversion recovery (FAIR). Materials and methods: Magnetic resonance imaging of lung perfusion using arterial spin labeling sequence was performed in supine position in ten healthy volunteers on a 1.5 T whole body scanner (GE Healthcare). Five coronal slices at an interval of 3 cm from dorsal to ventral (labeled as P3, P6, P9, P12, P15, sequently) were obtained when the volunteers performed breath holding on end expiration and the relative pulmonary blood flow (rPBF) was measured. Then, another coronal perfusion-weighted image of P3 slice was obtained on end inspiration. Tagging efficiency of pulmonary parenchyma with IR (ΔSI), rPBF and area of the P3 slice were analyzed. Results: (1) Along the direction of gravity, a gradient was visually perceived as a vertical increase in rPBF. There were significant statistic differences in rPBF between any two coronal planes except that between P12 and P15. In supine position, regression coefficients of right and left lung were -4.98 and -5.16, respectively. This means that rPBF decreased 4.98 (right) and 5.16 (left) for each centimeter above the dorsal. No statistical difference was seen between ROIs placed along iso-gravitational plane. (2) For a same slice, there were significant statistic differences in ΔSI, rPBF and area at different respiratory phases (P < 0.05). Greater ΔSI and more perfusion were observed on end expiration than on end inspiration. The area was larger on end inspiration than on end expiration. Conclusion: Both gravity and respiratory phase are important determinants of pulmonary perfusion heterogeneity. FAIR is sensitive to demonstrate gravity- and respiratory phase-dependent differences in lung perfusion. Positioning the patient so that the area of interest is down-gravity and asking patient to hold breath

  4. Demonstration of pulmonary perfusion heterogeneity induced by gravity and lung inflation using arterial spin labeling

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli7938@chinaren.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com; Sun Fei [GE Healthcare (China)], E-mail: Fei.sun@med.ge.com

    2010-02-15

    Objective: To evaluate the effect of gravity and lung inflation on pulmonary perfusion heterogeneity in human lung using an arterial spin labeling (ASL) sequence called flow sensitive alternating inversion recovery (FAIR). Materials and methods: Magnetic resonance imaging of lung perfusion using arterial spin labeling sequence was performed in supine position in ten healthy volunteers on a 1.5 T whole body scanner (GE Healthcare). Five coronal slices at an interval of 3 cm from dorsal to ventral (labeled as P3, P6, P9, P12, P15, sequently) were obtained when the volunteers performed breath holding on end expiration and the relative pulmonary blood flow (rPBF) was measured. Then, another coronal perfusion-weighted image of P3 slice was obtained on end inspiration. Tagging efficiency of pulmonary parenchyma with IR ({delta}SI), rPBF and area of the P3 slice were analyzed. Results: (1) Along the direction of gravity, a gradient was visually perceived as a vertical increase in rPBF. There were significant statistic differences in rPBF between any two coronal planes except that between P12 and P15. In supine position, regression coefficients of right and left lung were -4.98 and -5.16, respectively. This means that rPBF decreased 4.98 (right) and 5.16 (left) for each centimeter above the dorsal. No statistical difference was seen between ROIs placed along iso-gravitational plane. (2) For a same slice, there were significant statistic differences in {delta}SI, rPBF and area at different respiratory phases (P < 0.05). Greater {delta}SI and more perfusion were observed on end expiration than on end inspiration. The area was larger on end inspiration than on end expiration. Conclusion: Both gravity and respiratory phase are important determinants of pulmonary perfusion heterogeneity. FAIR is sensitive to demonstrate gravity- and respiratory phase-dependent differences in lung perfusion. Positioning the patient so that the area of interest is down-gravity and asking patient

  5. A neuroradiologist's guide to arterial spin labeling MRI in clinical practice

    International Nuclear Information System (INIS)

    Arterial spin labeling (ASL) is a non-invasive MRI technique to measure cerebral blood flow (CBF). This review provides a practical guide and overview of the clinical applications of ASL of the brain, as well its potential pitfalls. The technical and physiological background is also addressed. At present, main areas of interest are cerebrovascular disease, dementia and neuro-oncology. In cerebrovascular disease, ASL is of particular interest owing to its quantitative nature and its capability to determine cerebral arterial territories. In acute stroke, the source of the collateral blood supply in the penumbra may be visualised. In chronic cerebrovascular disease, the extent and severity of compromised cerebral perfusion can be visualised, which may be used to guide therapeutic or preventative intervention. ASL has potential for the detection and follow-up of arteriovenous malformations. In the workup of dementia patients, ASL is proposed as a diagnostic alternative to PET. It can easily be added to the routinely performed structural MRI examination. In patients with established Alzheimer's disease and frontotemporal dementia, hypoperfusion patterns are seen that are similar to hypometabolism patterns seen with PET. Studies on ASL in brain tumour imaging indicate a high correlation between areas of increased CBF as measured with ASL and increased cerebral blood volume as measured with dynamic susceptibility contrast-enhanced perfusion imaging. Major advantages of ASL for brain tumour imaging are the fact that CBF measurements are not influenced by breakdown of the blood-brain barrier, as well as its quantitative nature, facilitating multicentre and longitudinal studies. (orig.)

  6. A neuroradiologist's guide to arterial spin labeling MRI in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Grade, M. [Queen Square, UCL Institute of Neurology, London (United Kingdom); Stanford School of Medicine, Stanford, CA (United States); Hernandez Tamames, J.A. [Rey Juan Carlos University, Medical Image Analysis and Biometry Laboratory, Madrid (Spain); Erasmus MC - University Medical Centre Rotterdam, Department of Radiology, PO Box 2040, Rotterdam (Netherlands); Pizzini, F.B. [Queen Square, UCL Institute of Neurology, London (United Kingdom); Verona University Hospital, Neuroradiology, Department of Diagnostics and Pathology, Verona (Italy); Achten, E. [Ghent University Hospital, Neuroradiology, Department of Radiology, Ghent (Belgium); Golay, X. [Queen Square, UCL Institute of Neurology, London (United Kingdom); Smits, M. [Erasmus MC - University Medical Centre Rotterdam, Department of Radiology, PO Box 2040, Rotterdam (Netherlands)

    2015-12-15

    Arterial spin labeling (ASL) is a non-invasive MRI technique to measure cerebral blood flow (CBF). This review provides a practical guide and overview of the clinical applications of ASL of the brain, as well its potential pitfalls. The technical and physiological background is also addressed. At present, main areas of interest are cerebrovascular disease, dementia and neuro-oncology. In cerebrovascular disease, ASL is of particular interest owing to its quantitative nature and its capability to determine cerebral arterial territories. In acute stroke, the source of the collateral blood supply in the penumbra may be visualised. In chronic cerebrovascular disease, the extent and severity of compromised cerebral perfusion can be visualised, which may be used to guide therapeutic or preventative intervention. ASL has potential for the detection and follow-up of arteriovenous malformations. In the workup of dementia patients, ASL is proposed as a diagnostic alternative to PET. It can easily be added to the routinely performed structural MRI examination. In patients with established Alzheimer's disease and frontotemporal dementia, hypoperfusion patterns are seen that are similar to hypometabolism patterns seen with PET. Studies on ASL in brain tumour imaging indicate a high correlation between areas of increased CBF as measured with ASL and increased cerebral blood volume as measured with dynamic susceptibility contrast-enhanced perfusion imaging. Major advantages of ASL for brain tumour imaging are the fact that CBF measurements are not influenced by breakdown of the blood-brain barrier, as well as its quantitative nature, facilitating multicentre and longitudinal studies. (orig.)

  7. Arterial spin-labelling perfusion MRI and outcome in neonates with hypoxic-ischemic encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Vis, Jill B. de; Hendrikse, Jeroen [University Medical Center Utrecht, Department of Radiology, HP E 01.132, P.O. Box 85500, Utrecht (Netherlands); Petersen, Esben T. [University Medical Center Utrecht, Department of Radiology, HP E 01.132, P.O. Box 85500, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiotherapy, Utrecht (Netherlands); Vries, Linda S. de; Bel, Frank van; Alderliesten, Thomas; Negro, Simona; Groenendaal, Floris; Benders, Manon J.N.L. [Wilhelmina Children' s Hospital/University Medical Center Utrecht, Department of Neonatology, Utrecht (Netherlands)

    2015-01-15

    Hyperperfusion may be related to outcome in neonates with hypoxic-ischemic encephalopathy (HIE). The purpose of this study was to evaluate whether arterial spin labelling (ASL) perfusion is associated with outcome in neonates with HIE and to compare the predictive value of ASL MRI to known MRI predictive markers. Twenty-eight neonates diagnosed with HIE and assessed with MR imaging (conventional MRI, diffusion-weighted MRI, MR spectroscopy [MRS], and ASL MRI) were included. Perfusion in the basal ganglia and thalami was measured. Outcome at 9 or 18 months of age was scored as either adverse (death or cerebral palsy) or favourable. The median (range) perfusion in the basal ganglia and thalami (BGT) was 63 (28-108) ml/100 g/min in the neonates with adverse outcome and 28 (12-51) ml/100 g/min in the infants with favourable outcome (p < 0.01). The area-under-the-curve was 0.92 for ASL MRI, 0.97 for MRI score, 0.96 for Lac/NAA and 0.92 for ADC in the BGT. The combination of Lac/NAA and ASL MRI results was the best predictor of outcome (r {sup 2} = 0.86, p < 0.001). Higher ASL perfusion values in neonates with HIE are associated with a worse neurodevelopmental outcome. A combination of the MRS and ASL MRI information is the best predictor of outcome. (orig.)

  8. Arterial Spin Labeling Perfusion Study in the Patients with Subacute Mild Traumatic Brain Injury.

    Directory of Open Access Journals (Sweden)

    Che-Ming Lin

    Full Text Available This study uses a MRI technique, three-dimension pulse continuous arterial spin labeling (3D-PCASL, to measure the patient's cerebral blood flow (CBF at the subacute stage of mild traumatic brain injury (MTBI in order to analyze the relationship between cerebral blood flow and neurocognitive deficits.To provide the relationship between cortical CBF and neuropsychological dysfunction for the subacute MTBI patients.After MTBI, perfusion MR imaging technique (3D-PCASL measures the CBF of MTBI patients (n = 23 within 1 month and that of normal controls (n = 22 to determine the quantity and location of perfusion defect. The correlation between CBF abnormalities and cognitive deficits was elucidated by combining the results of the neuropsychological tests of the patients.We observed a substantial reduction in CBF in the bilateral frontal and left occipital cortex as compared with the normal persons. In addition, there were correlation between post concussive symptoms (including dizziness and simulator sickness and CBF in the hypoperfused areas. The more severe symptom was correlated with higher CBF in bilateral frontal and left occipital lobes.First, this study determined that despite no significant abnormality detected on conventional CT and MRI studies, hypoperfusion was observed in MTBI group using 3D-PCASL technique in subacute stage, which suggested that this approach may increase sensitivity to MTBI. Second, the correlation between CBF and the severity of post concussive symptoms suggested that changes in cerebral hemodynamics may play a role in pathophysiology underlies the symptoms.

  9. Arterial spin labelling at 3-T MR imaging for detection of individuals with Alzheimer's disease

    International Nuclear Information System (INIS)

    The purpose of this study was to determine whether arterial spin labelling (ASL) at 3-T MR imaging can be used to discriminate individuals with Alzheimer's disease (AD) from cognitively normal subjects. Twenty AD patients and 23 cognitively normal control subjects were studied using ASL on a 3-T MR imager. Absolute regional cerebral blood flow (rCBF) maps were calculated. In addition, normalized rCBF maps were obtained using CBF in the sensorimotor cortex for normalization. A voxel-wise comparison of these rCBF maps between the AD and control groups was performed using the two-sample t test. Individuals with AD were discriminated from control subjects based on mean rCBF values within a region-of-interest defined by the t test, and the discriminating performance was evaluated by the receiver operating characteristic (ROC) analysis. Comparisons of both absolute and normalized rCBF maps revealed areas of significant hypoperfusion caused by the effects of AD in the bilateral precunei and posterior cingulate gyri. ROC analyses resulted in area under the curve (AUC) values of 0.861 to 0.877 for absolute and 0.910 to 0.932 for normalized rCBF. Our results suggest that ASL at 3-T MR imaging can be used to help discriminate individuals with AD from normal subjects. (orig.)

  10. ASAP (Automatic Software for ASL Processing): A toolbox for processing Arterial Spin Labeling images.

    Science.gov (United States)

    Mato Abad, Virginia; García-Polo, Pablo; O'Daly, Owen; Hernández-Tamames, Juan Antonio; Zelaya, Fernando

    2016-04-01

    The method of Arterial Spin Labeling (ASL) has experienced a significant rise in its application to functional imaging, since it is the only technique capable of measuring blood perfusion in a truly non-invasive manner. Currently, there are no commercial packages for processing ASL data and there is no recognized standard for normalizing ASL data to a common frame of reference. This work describes a new Automated Software for ASL Processing (ASAP) that can automatically process several ASL datasets. ASAP includes functions for all stages of image pre-processing: quantification, skull-stripping, co-registration, partial volume correction and normalization. To assess the applicability and validity of the toolbox, this work shows its application in the study of hypoperfusion in a sample of healthy subjects at risk of progressing to Alzheimer's disease. ASAP requires limited user intervention, minimizing the possibility of random and systematic errors, and produces cerebral blood flow maps that are ready for statistical group analysis. The software is easy to operate and results in excellent quality of spatial normalization. The results found in this evaluation study are consistent with previous studies that find decreased perfusion in Alzheimer's patients in similar regions and demonstrate the applicability of ASAP. PMID:26612079

  11. Application of Arterial Spin Labelling in the Assessment of Ocular Tissues

    Science.gov (United States)

    Pontré, B.

    2016-01-01

    Arterial spin labelling (ASL) is a noninvasive magnetic resonance imaging (MRI) modality, capable of measuring blood perfusion without the use of a contrast agent. While ASL implementation for imaging the brain and monitoring cerebral blood flow has been reviewed in depth, the technique is yet to be widely used for ocular tissue imaging. The human retina is a very thin but highly stratified structure and it is also situated close to the surface of the body which is not ideal for MR imaging. Hence, the application of MR imaging and ASL in particular has been very challenging for ocular tissues and retina. That is despite the fact that almost all of retinal pathologies are accompanied by blood perfusion irregularities. In this review article, we have focused on the technical aspects of the ASL and their implications for its optimum adaptation for retinal blood perfusion monitoring. Retinal blood perfusion has been assessed through qualitative or invasive quantitative methods but the prospect of imaging flow using ASL would increase monitoring and assessment of retinal pathologies. The review provides details of ASL application in human ocular blood flow assessment. PMID:27066501

  12. 3D GRASE PROPELLER: Improved Image Acquisition Technique for Arterial Spin Labeling Perfusion Imaging

    Science.gov (United States)

    Tan, Huan; Hoge, W. Scott; Hamilton, Craig A.; Günther, Matthias; Kraft, Robert A.

    2014-01-01

    Arterial spin labeling (ASL) is a non-invasive technique that can quantitatively measure cerebral blood flow (CBF). While traditionally ASL employs 2D EPI or spiral acquisition trajectories, single-shot 3D GRASE is gaining popularity in ASL due to inherent SNR advantage and spatial coverage. However, a major limitation of 3D GRASE is through-plane blurring caused by T2 decay. A novel technique combining 3D GRASE and a PROPELLER trajectory (3DGP) is presented to minimize through-plane blurring without sacrificing perfusion sensitivity or increasing total scan time. Full brain perfusion images were acquired at a 3×3×5mm3 nominal voxel size with Q2TIPS-FAIR as the ASL preparation sequence. Data from 5 healthy subjects was acquired on a GE 1.5T scanner in less than 4 minutes per subject. While showing good agreement in CBF quantification with 3D GRASE, 3DGP demonstrated reduced through-plane blurring, improved anatomical details, high repeatability and robustness against motion, making it suitable for routine clinical use. PMID:21254211

  13. Arterial spin-labelling perfusion MRI and outcome in neonates with hypoxic-ischemic encephalopathy

    International Nuclear Information System (INIS)

    Hyperperfusion may be related to outcome in neonates with hypoxic-ischemic encephalopathy (HIE). The purpose of this study was to evaluate whether arterial spin labelling (ASL) perfusion is associated with outcome in neonates with HIE and to compare the predictive value of ASL MRI to known MRI predictive markers. Twenty-eight neonates diagnosed with HIE and assessed with MR imaging (conventional MRI, diffusion-weighted MRI, MR spectroscopy [MRS], and ASL MRI) were included. Perfusion in the basal ganglia and thalami was measured. Outcome at 9 or 18 months of age was scored as either adverse (death or cerebral palsy) or favourable. The median (range) perfusion in the basal ganglia and thalami (BGT) was 63 (28-108) ml/100 g/min in the neonates with adverse outcome and 28 (12-51) ml/100 g/min in the infants with favourable outcome (p 2 = 0.86, p < 0.001). Higher ASL perfusion values in neonates with HIE are associated with a worse neurodevelopmental outcome. A combination of the MRS and ASL MRI information is the best predictor of outcome. (orig.)

  14. Quantitative perfusion imaging with pulsed arterial spin labeling. A phantom study

    International Nuclear Information System (INIS)

    Pulsed arterial spin labeling (PASL) is a magnetic resonance (MR) method for measuring cerebral blood flow. Although several validation studies for PASL in animals and humans have been reported, no reports have detailed the fundamental study of PASL using a flow phantom. We compared the true and theoretical flow rates in a flow phantom to confirm the analytical validity of quantitative perfusion imaging with Q2TIPS sequence. We built a flow phantom consisting of a 40-mm diameter plastic syringe filled with plastic beads and small plastic tubes 4 mm in diameter. Gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA)-doped 8L water solution (0.1 mM) was circulated between the syringe and a tank through a plastic tube by a constant flow pump while the flow rate was adjusted between 0 and 2.61 cm/s. Q2TIPS sequence parameters were TI1=50 ms and TI2=1400 ins. Five imaging slices of 50 subtraction images were acquired sequentially in a distal-to-proximal direction using a single-shot echo planar imaging (EPI) technique. The theoretical flow rate calculated based upon the previously reported kinetic model for Q2TIPS was compared with the true flow rate. A good linear relationship was observed between the theoretical, F', and true flow rates, F, in a flow rate range of 1.43 to 1.95 cm/s (F'=1.024·F-1.915, R2=0.902). The ratio of theoretical to true flow rate was 92 (+/-) 4%. Flow rate was quantified with reasonable accuracy when the entire amount of labeled bolus within the phantom could be recovered. Our experiment confirmed the analytical validity of Q2TIPS and suggested that blood flow measurement may be feasible using the Q2TIPS pulse sequence and kinetic model of the PASL equation. (author)

  15. Improving Cerebral Blood Flow Quantification for Arterial Spin Labeled Perfusion MRI by Removing Residual Motion Artifacts and Global Signal Fluctuations

    OpenAIRE

    Wang, Ze

    2012-01-01

    Denoising is critical to improving the quality and stability of cerebral blood flow (CBF) quantification in arterial spin labeled (ASL) perfusion MRI due to the intrinsic low signal-to-noise-ratio (SNR) of ASL data. Previous studies have been focused on reducing the spatial or temporal noise using standard filtering techniques, and less attention has been paid to two global nuisance effects, the residual motion artifacts and the global signal fluctuations. Since both nuisances affect the whol...

  16. Volumetric Cerebral Perfusion Imaging in Healthy Adults: Regional Distribution, Laterality, and Repeatability of Pulsed Continuous Arterial Spin Labeling (PCASL)

    OpenAIRE

    Pfefferbaum, Adolf; Chanraud, Sandra; Pitel, Anne-Lise; Shankaranarayanan, Ajit; Alsop, David C.; Rohlfing, Torsten; Edith V. Sullivan

    2010-01-01

    The regional distribution, laterality, and reliability of volumetric pulsed continuous arterial spin labeling (PCASL) measurements of cerebral blood flow (CBF) in cortical, subcortical, and cerebellar regions were determined in 10 normal volunteers studied on two occasions separated by 3 to 7 days. Regional CBF, normalized for global perfusion, was highly reliable when measured on separate days. Several regions showed significant lateral asymmetry; notably, in frontal regions CBF was greater ...

  17. Voxel-level comparison of arterial spin-labeled perfusion magnetic resonance imaging in adolescents with internet gaming addiction

    OpenAIRE

    Feng, Qi; Chen, Xue; Sun, Jinhua; Zhou, Yan; Sun, Yawen; Ding, Weina; Zhang, Yong; Zhuang, Zhiguo; Xu, Jianrong; Du, Yasong

    2013-01-01

    Background Although recent studies have clearly demonstrated functional and structural abnormalities in adolescents with internet gaming addiction (IGA), less is known about how IGA affects perfusion in the human brain. We used pseudocontinuous arterial spin-labeling (ASL) perfusion functional magnetic resonance imaging (fMRI) to measure the effects of IGA on resting brain functions by comparing resting cerebral blood flow in adolescents with IGA and normal subjects. Methods Fifteen adolescen...

  18. Chronic and treatment-resistant depression: a study using arterial spin labeling perfusion MRI at 3Tesla.

    OpenAIRE

    Duhameau, Bérengère; Ferré, Jean-Christophe; Jannin, Pierre; Gauvrit, Jean-Yves; Vérin, Marc; Millet, Bruno; Drapier, Dominique

    2010-01-01

    International audience The aim of the present study was to compare patients displaying chronic and treatment-resistant depression with healthy controls, using the resting-state perfusion with arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) technique at 3T. The study focused on the subgenual anterior cingulate cortex (sACC), which is a key component in the pathophysiology of depression. Six patients with chronic and treatment-resistant depression and six healthy cont...

  19. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier;

    2010-01-01

    metabolism. So far, ASL has been restricted mostly to specialist centers due to a generally low SNR of the method and potential issues with user-dependent analysis needed to obtain quantitative measurement of cerebral blood flow (CBF). Here, we evaluated a particular implementation of ASL (called......Arterial Spin Labeling (ASL) is a method to measure perfusion using magnetically labeled blood water as an endogenous tracer. Being fully non-invasive, this technique is attractive for longitudinal studies of cerebral blood flow in healthy and diseased individuals, or as a surrogate marker of...... Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated and a...

  20. Multimodality evaluation of dural arteriovenous fistula with CT angiography, MR with arterial spin labeling, and digital subtraction angiography: case report.

    Science.gov (United States)

    Alexander, Matthew; McTaggart, Ryan; Santarelli, Justin; Fischbein, Nancy; Marks, Michael; Zaharchuk, Greg; Do, Huy

    2014-01-01

    Dural arteriovenous fistulae (DAVF) are cerebrovascular lesions with pathologic shunting into the venous system from arterial feeders. Digital subtraction angiography (DSA) has long been considered the gold standard for diagnosis, but advances in noninvasive imaging techniques now play a role in the diagnosis of these complex lesions. Herein, we describe the case of a patient with right-side pulsatile tinnitus and DAVF diagnosed using computed tomography angiography, magnetic resonance with arterial spin labeling, and DSA. Implications for imaging analysis of DAVFs and further research are discussed. PMID:23746119

  1. High accuracy of arterial spin labeling perfusion imaging in differentiation of pilomyxoid from pilocytic astrocytoma

    International Nuclear Information System (INIS)

    Pilomyxoid astrocytoma (PMA) is a relatively new tumor entity which has been added to the 2007 WHO Classification of tumors of the central nervous system. The goal of this study is to utilize arterial spin labeling (ASL) perfusion imaging to differentiate PMA from pilocytic astrocytoma (PA). Pulsed ASL and conventional MRI sequences of patients with PMA and PA in the past 5 years were retrospectively evaluated. Patients with history of radiation or treatment with anti-angiogenic drugs were excluded. A total of 24 patients (9 PMA, 15 PA) were included. There were statistically significant differences between PMA and PA in mean tumor/gray matter (GM) cerebral blood flow (CBF) ratios (1.3 vs 0.4, p < 0.001) and maximum tumor/GM CBF ratio (2.3 vs 1, p < 0.001). Area under the receiver operating characteristic (ROC) curves for differentiation of PMA from PA was 0.91 using mean tumor CBF, 0.95 using mean tumor/GM CBF ratios, and 0.89 using maximum tumor/GM CBF. Using a threshold value of 0.91, the mean tumor/GM CBF ratio was able to diagnose PMA with 77 % sensitivity, 100 % specificity, and a threshold value of 0.7, provided 88 % sensitivity and 86 % specificity. There was no statistically significant difference between the two tumors in enhancement pattern (p = 0.33), internal architecture (p = 0.15), or apparent diffusion coefficient (ADC) values (p = 0.07). ASL imaging has high accuracy in differentiating PMA from PA. The result of this study may have important applications in prognostication and treatment planning especially in patients with less accessible tumors such as hypothalamic-chiasmatic gliomas. (orig.)

  2. Comparison of arterial spin labeling and dynamic susceptibility contrast perfusion MRI in patients with acute stroke.

    Directory of Open Access Journals (Sweden)

    Yen-Chu Huang

    Full Text Available BACKGROUND: The aim of this study was to evaluate whether arterial spin labeling (ASL perfusion magnetic resonance imaging (MRI can reliably quantify perfusion deficit as compared to dynamic susceptibility contrast (DSC perfusion MRI. METHODS: Thirty-nine patients with acute ischemic stroke in the anterior circulation territory were recruited. All underwent ASL and DSC MRI perfusion scans within 30 hours after stroke onset and 31 patients underwent follow-up MRI scans. ASL cerebral blood flow (CBF and DSC time to maximum (T(max maps were used to calculate the perfusion defects. The ASL CBF lesion volume was compared to the DSC Tmax lesion volume by Pearson's correlation coefficient and likewise the ASL CBF and DSC T(max lesion volumes were compared to the final infarct sizes respectively. A repeated measures analysis of variance and least significant difference post hoc test was used to compare the mean lesion volumes among ASL CBF, DSC T(max >4-6 s and final infarct. RESULTS: Mean patient age was 72.6 years. The average time from stroke onset to MRI was 13.9 hours. The ASL lesion volume showed significant correlation with the DSC lesion volume for T(max >4, 5 and 6 s (r = 0.81, 0.82 and 0.80; p5 s (29.2 ml, p6 s (21.8 ml, p5 or 6 s were close to mean final infarct size. CONCLUSION: Quantitative measurement of ASL perfusion is well correlated with DSC perfusion. However, ASL perfusion may overestimate the perfusion defects and therefore further refinement of the true penumbra threshold and improved ASL technique are necessary before applying ASL in therapeutic trials.

  3. High accuracy of arterial spin labeling perfusion imaging in differentiation of pilomyxoid from pilocytic astrocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Nabavizadeh, S.A.; Assadsangabi, R.; Hajmomenian, M.; Vossough, A. [Perelman School of Medicine of the University of Pennsylvania, Department of Radiology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Santi, M. [Perelman School of Medicine of the University of Pennsylvania, Department of Pathology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States)

    2015-05-01

    Pilomyxoid astrocytoma (PMA) is a relatively new tumor entity which has been added to the 2007 WHO Classification of tumors of the central nervous system. The goal of this study is to utilize arterial spin labeling (ASL) perfusion imaging to differentiate PMA from pilocytic astrocytoma (PA). Pulsed ASL and conventional MRI sequences of patients with PMA and PA in the past 5 years were retrospectively evaluated. Patients with history of radiation or treatment with anti-angiogenic drugs were excluded. A total of 24 patients (9 PMA, 15 PA) were included. There were statistically significant differences between PMA and PA in mean tumor/gray matter (GM) cerebral blood flow (CBF) ratios (1.3 vs 0.4, p < 0.001) and maximum tumor/GM CBF ratio (2.3 vs 1, p < 0.001). Area under the receiver operating characteristic (ROC) curves for differentiation of PMA from PA was 0.91 using mean tumor CBF, 0.95 using mean tumor/GM CBF ratios, and 0.89 using maximum tumor/GM CBF. Using a threshold value of 0.91, the mean tumor/GM CBF ratio was able to diagnose PMA with 77 % sensitivity, 100 % specificity, and a threshold value of 0.7, provided 88 % sensitivity and 86 % specificity. There was no statistically significant difference between the two tumors in enhancement pattern (p = 0.33), internal architecture (p = 0.15), or apparent diffusion coefficient (ADC) values (p = 0.07). ASL imaging has high accuracy in differentiating PMA from PA. The result of this study may have important applications in prognostication and treatment planning especially in patients with less accessible tumors such as hypothalamic-chiasmatic gliomas. (orig.)

  4. Improving quality of arterial spin labeling MR imaging at 3 Tesla with a 32-channel coil and parallel imaging.

    OpenAIRE

    Ferré, Jean-Christophe; Petr, Jan; Bannier, Elise; Barillot, Christian; Gauvrit, Jean-Yves

    2012-01-01

    PURPOSE: To compare 12-channel and 32-channel phased-array coils and to determine the optimal parallel imaging (PI) technique and factor for brain perfusion imaging using Pulsed Arterial Spin labeling (PASL) at 3 Tesla (T). MATERIALS AND METHODS: Twenty-seven healthy volunteers underwent 10 different PASL perfusion PICORE Q2TIPS scans at 3T using 12-channel and 32-channel coils without PI and with GRAPPA or mSENSE using factor 2. PI with factor 3 and 4 were used only with the 32-channel coil....

  5. Assessment of Alzheimer’s Disease Risk with Functional Magnetic Resonance Imaging: An Arterial Spin Labeling Study

    OpenAIRE

    Bangen, Katherine J.; Restom, Khaled; Liu, Thomas T.; Wierenga, Christina E.; Jak, Amy J.; Salmon, David P.; Bondi, Mark W.

    2012-01-01

    Functional magnetic resonance imaging (fMRI) of older adults at risk for Alzheimer’s disease (AD) by virtue of their cognitive (i.e., mild cognitive impairment [MCI]) and/or genetic (i.e., apolipoprotein E [APOE] ε4 allele) status demonstrate divergent brain response patterns during memory encoding across studies. Using arterial spin labeling MRI, we examined the influence of AD risk on resting cerebral blood flow (CBF) as well as the CBF and blood oxygenation level dependent (BOLD) signal re...

  6. Noninvasive measurements of regional cerebral perfusion in preterm and term neonates by magnetic resonance arterial spin labeling

    DEFF Research Database (Denmark)

    Miranda Gimenez-Ricco, Maria Jo; Olofsson, K; Sidaros, Karam

    2006-01-01

    Magnetic resonance arterial spin labeling (ASL) at 3 Tesla has been investigated as a quantitative technique for measuring regional cerebral perfusion (RCP) in newborn infants. RCP values were measured in 49 healthy neonates: 32 preterm infants born before 34 wk of gestation and 17 term...... higher (p < 0.0001) than in cortical gray matter (19 and 16 mL/100 g/min) and white matter (15 and 10 mL/100 g/min), both in preterm neonates at term-equivalent age and in term neonates. Perfusion was significantly higher (p = 0.01) in the preterm group than in the term infants, indicating that RCP may...... be influenced by developmental and postnatal ages. This study demonstrates, for the first time, that noninvasive ASL at 3T may be used to measure RCP in healthy unsedated preterm and term neonates. ASL is, therefore, a viable tool that will allow serial studies of RCP in high-risk neonates...

  7. SU-D-18C-05: Variable Bolus Arterial Spin Labeling MRI for Accurate Cerebral Blood Flow and Arterial Transit Time Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, M; Jung, Y [Wake Forest School of Medicine, Winston-Salem, NC (United States)

    2014-06-01

    Purpose: Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition with variable post-labeling delays (PLD) and variable TRs allows for arterial transit time (ATT) mapping and leads to more accurate CBF quantification with a scan time saving of 48%. In addition, T1 and M0 maps can be obtained without a separate scan. In order to accurately estimate ATT and T1 of brain tissue from the ASL data, variable labeling durations were invented, entitled variable-bolus ASL. Methods: All images were collected on a healthy subject with a 3T Siemens Skyra scanner. Variable-bolus Psuedo-continuous ASL (PCASL) images were collected with 7 TI times ranging 100-4300ms in increments of 700ms with TR ranging 1000-5200ms. All boluses were 1600ms when the TI allowed, otherwise the bolus duration was 100ms shorter than the TI. All TI times were interleaved to reduce sensitivity to motion. Voxel-wise T1 and M0 maps were estimated using a linear least squares fitting routine from the average singal from each TI time. Then pairwise subtraction of each label/control pair and averaging for each TI time was performed. CBF and ATT maps were created using the standard model by Buxton et al. with a nonlinear fitting routine using the T1 tissue map. Results: CBF maps insensitive to ATT were produced along with ATT maps. Both maps show patterns and averages consistent with literature. The T1 map also shows typical T1 contrast. Conclusion: It has been demonstrated that variablebolus ASL produces CBF maps free from the errors due to ATT and tissue T1 variations and provides M0, T1, and ATT maps which have potential utility. This is accomplished with a single scan in a feasible scan time (under 6 minutes) with low sensivity to motion.

  8. SU-D-18C-05: Variable Bolus Arterial Spin Labeling MRI for Accurate Cerebral Blood Flow and Arterial Transit Time Mapping

    International Nuclear Information System (INIS)

    Purpose: Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition with variable post-labeling delays (PLD) and variable TRs allows for arterial transit time (ATT) mapping and leads to more accurate CBF quantification with a scan time saving of 48%. In addition, T1 and M0 maps can be obtained without a separate scan. In order to accurately estimate ATT and T1 of brain tissue from the ASL data, variable labeling durations were invented, entitled variable-bolus ASL. Methods: All images were collected on a healthy subject with a 3T Siemens Skyra scanner. Variable-bolus Psuedo-continuous ASL (PCASL) images were collected with 7 TI times ranging 100-4300ms in increments of 700ms with TR ranging 1000-5200ms. All boluses were 1600ms when the TI allowed, otherwise the bolus duration was 100ms shorter than the TI. All TI times were interleaved to reduce sensitivity to motion. Voxel-wise T1 and M0 maps were estimated using a linear least squares fitting routine from the average singal from each TI time. Then pairwise subtraction of each label/control pair and averaging for each TI time was performed. CBF and ATT maps were created using the standard model by Buxton et al. with a nonlinear fitting routine using the T1 tissue map. Results: CBF maps insensitive to ATT were produced along with ATT maps. Both maps show patterns and averages consistent with literature. The T1 map also shows typical T1 contrast. Conclusion: It has been demonstrated that variablebolus ASL produces CBF maps free from the errors due to ATT and tissue T1 variations and provides M0, T1, and ATT maps which have potential utility. This is accomplished with a single scan in a feasible scan time (under 6 minutes) with low sensivity to motion

  9. Spin labels. Applications in biology

    International Nuclear Information System (INIS)

    The main applications of spin labels in the study of biomembranes, enzymes, nucleic acids, in pharmacology, spin immunoassay are reviewed along with the fundamentals of the spin label method. 137 references. (author)

  10. Improving cerebral blood flow quantification for arterial spin labeled perfusion MRI by removing residual motion artifacts and global signal fluctuations.

    Science.gov (United States)

    Wang, Ze

    2012-12-01

    Denoising is critical to improving the quality and stability of cerebral blood flow (CBF) quantification in arterial spin labeled (ASL) perfusion magnetic resonance imaging (MRI) due to the intrinsic low signal-to-noise-ratio (SNR) of ASL data. Previous studies have been focused on reducing the spatial or temporal noise using standard filtering techniques, and less attention has been paid to two global nuisance effects, the residual motion artifacts and the global signal fluctuations. Since both nuisances affect the whole brain, removing them in advance should enhance the CBF quantification quality for ASL MRI. The purpose of this paper was to assess this potential benefit. Three methods were proposed to suppress each or both of the two global nuisances. Their performances for CBF quantification were validated using ASL data acquired from 13 subjects. Evaluation results showed that covarying out both global nuisances significantly improved temporal SNR and test-retest stability of CBF measurement. Although the concept of removing both nuisances is not technically novel per se, this paper clearly showed the benefits for ASL CBF quantification. Dissemination of the proposed methods in a free ASL data processing toolbox should be of interest to a broad range of ASL users. PMID:22789842

  11. Early-stage differentiation between presenile Alzheimer's disease and frontotemporal dementia using arterial spin labeling MRI

    Energy Technology Data Exchange (ETDEWEB)

    Steketee, Rebecca M.E.; Meijboom, Rozanna; Lugt, Aad van der; Smits, Marion [Erasmus MC - University Medical Center, Department of Radiology, PO Box 2040, Rotterdam (Netherlands); Bron, Esther E.; Klein, Stefan [Erasmus MC - University Medical Center, Biomedical Imaging Group Rotterdam, Departments of Medical Informatics and Radiology, PO Box 2040, Rotterdam (Netherlands); Houston, Gavin C. [GE Healthcare, Hatfield (United Kingdom); Mutsaerts, Henri J.M.M. [Academic Medical Center, Department of Radiology, PO Box 22660, Amsterdam (Netherlands); Mendez Orellana, Carolina P. [Erasmus MC - University Medical Center, Department of Radiology, PO Box 2040, Rotterdam (Netherlands); Erasmus MC - University Medical Center, Department of Neurology, PO Box 2040, Rotterdam (Netherlands); Jong, Frank Jan de; Swieten, John C. van [Erasmus MC - University Medical Center, Department of Neurology, PO Box 2040, Rotterdam (Netherlands)

    2016-01-15

    To investigate arterial spin labeling (ASL)-MRI for the early diagnosis of and differentiation between the two most common types of presenile dementia: Alzheimer's disease (AD) and frontotemporal dementia (FTD), and for distinguishing age-related from pathological perfusion changes. Thirteen AD and 19 FTD patients, and 25 age-matched older and 22 younger controls underwent 3D pseudo-continuous ASL-MRI at 3 T. Gray matter (GM) volume and cerebral blood flow (CBF), corrected for partial volume effects, were quantified in the entire supratentorial cortex and in 10 GM regions. Sensitivity, specificity and diagnostic performance were evaluated in regions showing significant CBF differences between patient groups or between patients and older controls. AD compared with FTD patients had hypoperfusion in the posterior cingulate cortex, differentiating these with a diagnostic performance of 74 %. Compared to older controls, FTD patients showed hypoperfusion in the anterior cingulate cortex, whereas AD patients showed a more widespread regional hypoperfusion as well as atrophy. Regional atrophy was not different between AD and FTD. Diagnostic performance of ASL to differentiate AD or FTD from controls was good (78-85 %). Older controls showed global hypoperfusion compared to young controls. ASL-MRI contributes to early diagnosis of and differentiation between presenile AD and FTD. (orig.)

  12. Arterial spin labeling MR imaging for characterisation of renal masses in patients with impaired renal function: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Pedrosa, Ivan [Beth Israel Deaconess Medical Center and Harvard Medical School, Department of Radiology, Boston, MA (United States); UT Southwestern Medical Center, Department of Radiology, Dallas, TX (United States); Rafatzand, Khashayar; Robson, Philip; Alsop, David C. [Beth Israel Deaconess Medical Center and Harvard Medical School, Department of Radiology, Boston, MA (United States); Wagner, Andrew A. [Beth Israel Deaconess Medical Center and Harvard Medical School, Surgery, Division of Urology, Boston, MA (United States); Atkins, Michael B. [Beth Israel Deaconess Medical Center and Harvard Medical School, Hematology/Oncology, Boston, MA (United States); Rofsky, Neil M. [University of Texas Southwestern Medical Center, Departments of Radiology, Dallas, TX (United States)

    2012-02-15

    To retrospectively evaluate the feasibility of arterial spin labeling (ASL) magnetic resonance imaging (MRI) for the assessment of vascularity of renal masses in patients with impaired renal function. Between May 2007 and November 2008, 11/67 consecutive patients referred for MRI evaluation of a renal mass underwent unenhanced ASL-MRI due to moderate-to-severe chronic or acute renal failure. Mean blood flow in vascularised and non-vascularised lesions and the relation between blood flow and final diagnosis of malignancy were correlated with a 2-sided homogeneous variance t-test and the Fisher Exact Test, respectively. A p value <0.05 was considered statistically significant. Seventeen renal lesions were evaluated in 11 patients (8 male; mean age = 70 years) (range 57-86). The median eGFR was 24 mL/min/1.73 m{sup 2} (range 7-39). The average blood flow of 11 renal masses interpreted as ASL-positive (134 +/- 85.7 mL/100 g/min) was higher than that of 6 renal masses interpreted as ASL-negative (20.5 +/- 8.1 mL/100 g/min)(p = 0.015). ASL-positivity correlated with malignancy (n = 3) or epithelial atypia (n = 1) at histopathology or progression at follow up (n = 7). ASL detection of vascularity in renal masses in patients with impaired renal function is feasible and seems to indicate neoplasia although the technique requires further evaluation. (orig.)

  13. Perfusion imaging of parotid gland tumours: usefulness of arterial spin labeling for differentiating Warthin's tumours

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroki; Watanabe, Haruo [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Kanematsu, Masayuki [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Kajita, Kimihiro [Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Mizuta, Keisuke; Aoki, Mitsuhiro [Gifu University School of Medicine, Department of Otolaryngology, Gifu (Japan); Okuaki, Tomoyuki [Philips Healthcare, Tokyo (Japan)

    2015-11-15

    To assess prospectively the efficacy of arterial spin labelling (ASL) against conventional and diffusion-weighted (DW) MR imaging for differentiating parotid gland tumours. We included 10 pleomorphic adenomas, 12 Warthin's tumours, and nine malignant tumours of the parotid glands. Only tumours larger than 10 mm were included in this study. All parotid gland tumours underwent T1-weighted, T2-weighted, DW, and ASL imaging. Tumour-to-parotid gland signal intensity ratios (SIRs) and apparent diffusion coefficients (ADCs) of solid components were correlated with these pathologies. SIRs on T2-weighted images and ADCs were higher in pleomorphic adenomas than in Warthin's tumours (p <.01) and malignant tumours (p <.01). SIRs on ASL were higher in Warthin's tumours than in pleomorphic adenomas (p <.01) and malignant tumours (p <.05). Az value of SIRs on ASL for differentiating Warthin's tumours from the other pathologies was 0.982. The sensitivity, specificity, and accuracy of SIRs on ASL for the diagnosis of Warthin's tumours at an optimal SIR threshold of over 8.70 were 91.7 %, 94.7 %, and 93.5 %, respectively. ASL with SIR measurements could non-invasively evaluate tumour blood flow of parotid gland tumours and differentiate Warthin's tumours from pleomorphic adenomas and malignant tumours. (orig.)

  14. Early-stage differentiation between presenile Alzheimer's disease and frontotemporal dementia using arterial spin labeling MRI

    International Nuclear Information System (INIS)

    To investigate arterial spin labeling (ASL)-MRI for the early diagnosis of and differentiation between the two most common types of presenile dementia: Alzheimer's disease (AD) and frontotemporal dementia (FTD), and for distinguishing age-related from pathological perfusion changes. Thirteen AD and 19 FTD patients, and 25 age-matched older and 22 younger controls underwent 3D pseudo-continuous ASL-MRI at 3 T. Gray matter (GM) volume and cerebral blood flow (CBF), corrected for partial volume effects, were quantified in the entire supratentorial cortex and in 10 GM regions. Sensitivity, specificity and diagnostic performance were evaluated in regions showing significant CBF differences between patient groups or between patients and older controls. AD compared with FTD patients had hypoperfusion in the posterior cingulate cortex, differentiating these with a diagnostic performance of 74 %. Compared to older controls, FTD patients showed hypoperfusion in the anterior cingulate cortex, whereas AD patients showed a more widespread regional hypoperfusion as well as atrophy. Regional atrophy was not different between AD and FTD. Diagnostic performance of ASL to differentiate AD or FTD from controls was good (78-85 %). Older controls showed global hypoperfusion compared to young controls. ASL-MRI contributes to early diagnosis of and differentiation between presenile AD and FTD. (orig.)

  15. Changes in cerebral blood flow and vasoreactivity to CO(2) measured by Arterial Spin Labeling after 6 days at 4,350 m.

    OpenAIRE

    Villien, Marjorie,; Bouzat, Pierre; Rupp, Thomas; Robach, Paul; Lamalle, Laurent; Troprès, Irène; Estève, François; Krainik, Alexandre; Lévy, Patrick; Warnking, Jan; Verges, Samuel

    2013-01-01

    Changes in cerebral perfusion and CO(2) cerebrovascular reactivity during and immediately after a sojourn at high altitude remain unclear but may be critical for acclimatization. The aim of the present study was to assess the effects of 6days at 4,350m on cerebral perfusion and cerebrovascular reactivity (CVR) to CO(2) by arterial spin labeling (ASL) magnetic resonance imaging at sea level and to compare it with transcranial Doppler (TCD) results at altitude. Eleven healthy male subjects, non...

  16. Brain perfusion in dementia with Lewy bodies and Alzheimer’s disease: an arterial spin labeling MRI study on prodromal and mild dementia stages

    OpenAIRE

    Roquet, Daniel; Sourty, Marion; Botzung, Anne; Armspach, Jean-Paul; Blanc, Frédéric

    2016-01-01

    Background We aimed to describe specific changes in brain perfusion in patients with dementia with Lewy bodies (DLB) at both the prodromal (also called mild cognitive impairment) and mild dementia stages, relative to patients with Alzheimer’s disease (AD) and controls. Methods Altogether, 96 participants in five groups (prodromal DLB, prodromal AD, DLB with mild dementia, AD with mild dementia, and healthy elderly controls) took part in an arterial spin labeling MRI study. Three analyses were...

  17. Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla

    OpenAIRE

    Gillis, Keith A.; McComb, Christie; Foster, John E.; Taylor, Alison; Patel, Rajan K.; Morris, Scott; Alan G. Jardine; Schneider, Markus P; Roditi, Giles H; Delles, Christian; Mark, Patrick B.

    2014-01-01

    Background: Measurement of renal perfusion is a crucial part of measuring kidney function. Arterial spin labelling magnetic resonance imaging (ASL MRI) is a non-invasive method of measuring renal perfusion using magnetised blood as endogenous contrast. We studied the reproducibility of ASL MRI in normal volunteers. Methods: ASL MRI was performed in healthy volunteers on 2 occasions using a 3.0 Tesla MRI scanner with flow-sensitive alternating inversion recovery (FAIR) perfusion prep...

  18. Medullary hemangioblastoma in a child with von Hippel-Lindau disease: vascular tumor perfusion depicted by arterial spin labeling and dynamic contrast-enhanced imaging.

    Science.gov (United States)

    Goo, Hyun Woo; Ra, Young-Shin

    2015-07-01

    Medullary hemangioblastoma is very rare in children. Based on small nodular enhancement with peritumoral edema and without dilated feeding arteries on conventional MRI, hemangioblastoma, pilocytic astrocytoma, oligodendroglioma, and ganglioglioma were included in the differential diagnosis of the medullary tumor. In this case report, the authors emphasize the diagnostic value of arterial spin labeling and dynamic contrast-enhanced MRI in demonstrating vascular tumor perfusion of hemangioblastoma in a 12-year-old boy who was later found to have von Hippel-Lindau disease. PMID:25885801

  19. Arterial spin labelling MRI for assessment of cerebral perfusion in children with moyamoya disease: comparison with dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Goetti, Robert [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland); University Hospital Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); O' Gorman, Ruth [University Children' s Hospital Zurich, Center for MR Research, Zurich (Switzerland); Khan, Nadia [University Children' s Hospital Zurich, Moyamoya Center, Division of Neurosurgery, Department of Surgery, Zurich (Switzerland); Kellenberger, Christian J.; Scheer, Ianina [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland)

    2013-05-15

    This study seeks to evaluate the diagnostic accuracy of cerebral perfusion imaging with arterial spin labelling (ASL) MR imaging in children with moyamoya disease compared to dynamic susceptibility contrast (DSC) imaging. Ten children (7 females; age, 9.2 {+-} 5.4 years) with moyamoya disease underwent cerebral perfusion imaging with ASL and DSC on a 3-T MRI scanner in the same session. Cerebral perfusion images were acquired with ASL (pulsed continuous 3D ASL sequence, 32 axial slices, TR = 5.5 s, TE = 25 ms, FOV = 24 cm, matrix = 128 x 128) and DSC (gradient echo EPI sequence, 35 volumes of 28 axial slices, TR = 2,000 ms, TE = 36 ms, FOV = 24 cm, matrix = 96 x 96, 0.2 ml/kg Gd-DOTA). Cerebral blood flow maps were generated. ASL and DSC images were qualitatively assessed regarding perfusion of left and right ACA, MCA, and PCA territories by two independent readers using a 3-point-Likert scale and quantitative relative cerebral blood flow (rCBF) was calculated. Correlation between ASL and DSC for qualitative and quantitative assessment and the accuracy of ASL for the detection of reduced perfusion per territory with DSC serving as the standard of reference were calculated. With a good interreader agreement ({kappa} = 0.62) qualitative perfusion assessment with ASL and DSC showed a strong and significant correlation ({rho} = 0.77; p < 0.001), as did quantitative rCBF (r = 0.79; p < 0.001). ASL showed a sensitivity, specificity and accuracy of 94 %, 93 %, and 93 % for the detection of reduced perfusion per territory. In children with moyamoya disease, unenhanced ASL enables the detection of reduced perfusion per vascular territory with a good accuracy compared to contrast-enhanced DSC. (orig.)

  20. The Cerebral Blood Flow Biomedical Informatics Research Network (CBFBIRN) database and analysis pipeline for arterial spin labeling MRI data.

    Science.gov (United States)

    Shin, David D; Ozyurt, I Burak; Liu, Thomas T

    2013-01-01

    Arterial spin labeling (ASL) is a magnetic resonance imaging technique that provides a non-invasive and quantitative measure of cerebral blood flow (CBF). After more than a decade of active research, ASL is now emerging as a robust and reliable CBF measurement technique with increased availability and ease of use. There is a growing number of research and clinical sites using ASL for neuroscience research and clinical care. In this paper, we present an online CBF Database and Analysis Pipeline, collectively called the Cerebral Blood Flow Biomedical Informatics Research Network (CBFBIRN) that allows researchers to upload and share ASL and clinical data. In addition to serving the role as a central data repository, the CBFBIRN provides a streamlined data processing infrastructure for CBF quantification and group analysis, which has the potential to accelerate the discovery of new scientific and clinical knowledge. All capabilities and features built into the CBFBIRN are accessed online using a web browser through a secure login. In this work, we begin with a general description of the CBFBIRN system data model and its architecture, then devote the remainder of the paper to the CBFBIRN capabilities. The latter part of our work is divided into two processing modules: (1) Data Upload and CBF Quantification Module; (2) Group Analysis Module that supports three types of analysis commonly used in neuroscience research. To date, the CBFBIRN hosts CBF maps and associated clinical data from more than 1,300 individual subjects. The data have been contributed by more than 20 different research studies, investigating the effect of various conditions on CBF including Alzheimer's, schizophrenia, bipolar disorder, depression, traumatic brain injury, HIV, caffeine usage, and methamphetamine abuse. Several example results, generated by the CBFBIRN processing modules, are presented. We conclude with the lessons learned during implementation and deployment of the CBFBIRN and our

  1. The Cerebral Blood Flow Biomedical Informatics Research Network (CBFBIRN Database and Analysis Pipeline for Arterial Spin Labeling MRI Data

    Directory of Open Access Journals (Sweden)

    David D. Shin

    2013-10-01

    Full Text Available Arterial spin labeling (ASL is a MRI technique that provides a noninvasive and quantitative measure of cerebral blood flow (CBF. After more than a decade of active research, ASL is now emerging as a robust and reliable CBF measurement technique with increased availability and ease of use. There is a growing number of research and clinical sites using ASL for neuroscience research and clinical care. In this paper, we present an online CBF Database and Analysis Pipeline, collectively called the CBFBIRN that allows researchers to upload and share ASL and clinical data. In addition to serving the role as a central data repository, the CBFBIRN provides a streamlined data processing infrastructure for CBF quantification and group analysis, which has the potential to accelerate the discovery of new scientific and clinical knowledge. All capabilities and features built into the CBFBIRN are accessed online using a web browser through a secure login. In this work, we begin with a general description of the CBFBIRN system data model and its architecture, then devote the remainder of the paper to the CBFBIRN capabilities. The latter part of our work is divided into two processing modules: 1 Data Upload and CBF Quantification Module; 2 Group Analysis Module that supports three types of analysis commonly used in neuroscience research. To date, the CBFBIRN hosts CBF maps and associated clinical data from more than 1300 individual subjects. The data have been contributed by more than 20 different research studies, investigating the effect of various conditions on CBF including Alzheimer’s, schizophrenia, bipolar disorder, depression, traumatic brain injury, HIV, caffeine usage and Methamphetamine abuse. Several example results, generated by the CBFBIRN processing modules, are presented. We conclude with the lessons learned during implementation and deployment of the CBFBIRN and our experience in promoting data sharing.

  2. Temporal and extra-temporal hypoperfusion in medial temporal lobe epilepsy evaluated by arterial-spin-labeling based MRI

    International Nuclear Information System (INIS)

    Objective: To evaluate the feasibility of the lateralization of unilateral medial temporal lobe epilepsy (mTLE) by using arterial-spin-labeling (ASL) based perfusion MR imaging and investigate the changes of perfusion in the regions related to mTLE network and the relationship between the perfusion and the clinical status. Methods: Twenty-five patients with left-sided and 23 with right-sided mTLE were enrolled, and 30 healthy volunteers were recruited. The cerebral blood flow (CBF) of related region was measured based on pulsed-ASL sequence on Siemens 3 T scanner. The CBF of the mTLE group were compared with that in the controls by using ANOVA analysis. The asymmetric indices of CBF in the medial temporal lobe were calculated as the lesion side compared with the normal side in matched region in mTLE group. Results: Compared with the volunteers, the patients with mTLE showed the decrease of CBF in the bilateral medial and lateral temporal, the frontal and parietal regions relating to the default-mode network and more serious in lesion side. The CBF values of the medial temporal lobe were negatively correlated with the epilepsy duration (r=-0.51, P<0.01). The asymmetric index of CBF as-0.01 has a 76.0% (19/25) sensitivity and a 78.3% (18/23) specificity to distinguish the lesion side. Conclusions: The decrease of CBF in the temporal and extra-temporal region by ASL-based MRI suggests the functional abnormalities in the network involved by mTLE. The ASL technique is a useful tool for lateralizing the unilateral mTLE. (authors)

  3. Arterial spin labelling MRI for assessment of cerebral perfusion in children with moyamoya disease: comparison with dynamic susceptibility contrast MRI

    International Nuclear Information System (INIS)

    This study seeks to evaluate the diagnostic accuracy of cerebral perfusion imaging with arterial spin labelling (ASL) MR imaging in children with moyamoya disease compared to dynamic susceptibility contrast (DSC) imaging. Ten children (7 females; age, 9.2 ± 5.4 years) with moyamoya disease underwent cerebral perfusion imaging with ASL and DSC on a 3-T MRI scanner in the same session. Cerebral perfusion images were acquired with ASL (pulsed continuous 3D ASL sequence, 32 axial slices, TR = 5.5 s, TE = 25 ms, FOV = 24 cm, matrix = 128 x 128) and DSC (gradient echo EPI sequence, 35 volumes of 28 axial slices, TR = 2,000 ms, TE = 36 ms, FOV = 24 cm, matrix = 96 x 96, 0.2 ml/kg Gd-DOTA). Cerebral blood flow maps were generated. ASL and DSC images were qualitatively assessed regarding perfusion of left and right ACA, MCA, and PCA territories by two independent readers using a 3-point-Likert scale and quantitative relative cerebral blood flow (rCBF) was calculated. Correlation between ASL and DSC for qualitative and quantitative assessment and the accuracy of ASL for the detection of reduced perfusion per territory with DSC serving as the standard of reference were calculated. With a good interreader agreement (κ = 0.62) qualitative perfusion assessment with ASL and DSC showed a strong and significant correlation (ρ = 0.77; p < 0.001), as did quantitative rCBF (r = 0.79; p < 0.001). ASL showed a sensitivity, specificity and accuracy of 94 %, 93 %, and 93 % for the detection of reduced perfusion per territory. In children with moyamoya disease, unenhanced ASL enables the detection of reduced perfusion per vascular territory with a good accuracy compared to contrast-enhanced DSC. (orig.)

  4. Early response assessment in patients with multiple myeloma during anti-angiogenic therapy using arterial spin labelling: first clinical results

    International Nuclear Information System (INIS)

    To determine if arterial-spin-labelling (ASL) MRI can reliably detect early response to anti-angiogenic therapy in patients with multiple myeloma by comparison with clinical/haematological response. Nineteen consecutive patients (10 men; mean age 63.5 ± 9.1 years) were included in the present study. Inclusion criteria were diagnosis of stage III multiple myeloma and clinical indication for therapeutical administration of bortezomib or lenalidomide. We performed MRI on 3.0T MR in the baseline setting, 3 weeks after onset of therapy and after 8 weeks. Clinical responses were determined on the basis of international uniform response criteria in correlation with haematological parameters and medium-term patient outcome. MRI studies were performed after approval by the local institutional review board. Fifteen patients responded to anti-myeloma therapy; 4/19 patients were non-responders to therapy. Mean tumour perfusion assessed by ASL-MRI in a reference lesion was 220.7 ± 132.5 ml min-1 100 g-1 at baseline, and decreased to 125.7 ± 86.3 (134.5 ± 150.9) ml min-1 100 g-1 3 (8) weeks after onset of therapy (P < 0.02). The mean decrease in paraproteinaemia at week 3 (8) was 52.3 ± 47.7% (58.2 ± 58.7%), whereas β2-microglobulinaemia decreased by 20.3 ± 53.1% (23.3 ± 57.0%). Correlation of ASL perfusion with outcome was significant (P = 0.0037). ASL tumour perfusion measurements are a valuable surrogate parameter for early assessment of response to novel anti-angiogenic therapy. (orig.)

  5. Early response assessment in patients with multiple myeloma during anti-angiogenic therapy using arterial spin labelling: first clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Fenchel, Michael [Eberhard-Karls University, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Eberhard-Karls University, Department of Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Konaktchieva, Marina [Eberhard-Karls University, Department of Internal Medicine, Gastroenterology, Tuebingen (Germany); Weisel, Katja; Kraus, Sabina [Eberhard-Karls University, Department of Internal Medicine, Hematology, Tuebingen (Germany); Brodoefel, Harald; Claussen, Claus D.; Horger, Marius [Eberhard-Karls University, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2010-12-15

    To determine if arterial-spin-labelling (ASL) MRI can reliably detect early response to anti-angiogenic therapy in patients with multiple myeloma by comparison with clinical/haematological response. Nineteen consecutive patients (10 men; mean age 63.5 {+-} 9.1 years) were included in the present study. Inclusion criteria were diagnosis of stage III multiple myeloma and clinical indication for therapeutical administration of bortezomib or lenalidomide. We performed MRI on 3.0T MR in the baseline setting, 3 weeks after onset of therapy and after 8 weeks. Clinical responses were determined on the basis of international uniform response criteria in correlation with haematological parameters and medium-term patient outcome. MRI studies were performed after approval by the local institutional review board. Fifteen patients responded to anti-myeloma therapy; 4/19 patients were non-responders to therapy. Mean tumour perfusion assessed by ASL-MRI in a reference lesion was 220.7 {+-} 132.5 ml min{sup -1} 100 g{sup -1} at baseline, and decreased to 125.7 {+-} 86.3 (134.5 {+-} 150.9) ml min{sup -1} 100 g{sup -1} 3 (8) weeks after onset of therapy (P < 0.02). The mean decrease in paraproteinaemia at week 3 (8) was 52.3 {+-} 47.7% (58.2 {+-} 58.7%), whereas {beta}2-microglobulinaemia decreased by 20.3 {+-} 53.1% (23.3 {+-} 57.0%). Correlation of ASL perfusion with outcome was significant (P = 0.0037). ASL tumour perfusion measurements are a valuable surrogate parameter for early assessment of response to novel anti-angiogenic therapy. (orig.)

  6. Cerebral blood flow changes in hemodialysis and peritoneal dialysis patients: an arterial-spin labeling MR imaging.

    Science.gov (United States)

    Jiang, Xiao Lu; Wen, Ji Qiu; Zhang, Long Jiang; Zheng, Gang; Li, Xue; Zhang, Zhe; Liu, Ya; Zheng, Li Juan; Wu, Long; Chen, Hui Juan; Kong, Xiang; Luo, Song; Lu, Guang Ming; Ji, Xue Man; Zhang, Zong Jun

    2016-08-01

    We used arterial-spin labeling (ASL) MR imaging, a non-invasive technique to evaluate cerebral blood flow (CBF) changes in patients with end-stage renal disease (ESRD) undergoing peritoneal dialysis (PD) and hemodialysis (HD), and nondialysis ESRD patients compared with healthy cohort. Ninety seven ESRD patients including 32 PD patients (20 male, 12 female; mean age 33 ± 8 years), 33 HD patients (22 male, 11 female; mean age 33 ± 8 years) and 32 nondialysis patients (20 male, 12 female; mean age 35 ± 7 years) and 31 age- and gender-matched healthy controls (20 male, 11 female; mean age 32 ± 8 years) were included in this study. All subjects underwent ASL MR imaging, neuropsychologic tests, and ESRD patients underwent laboratory testing. CBF values were compared among PD, HD, nondialysis patients and control groups. Correlation analysis and multiple regression analysis were performed to investigate the association between CBF values and hemoglobin, neuropsychologic test results, serum creatinine, urea levels, disease duration, and dialysis duration. Elevated CBFs of whole brain region, gray matter, and white matter were found in all ESRD patient groups compared with healthy controls (all P differences for CBF between PD and HD patient groups. Negative correlations were observed between mean CBFs of whole brain region, gray matter, and white matter and the hemoglobin level in all ESRD patients. Multiple linear regression showed elevated CBF of multiple brain areas correlated with some neuropsychological tests in ESRD patients (all P differences of CBF change and cognitive function between PD and HD ESRD patients with long-term treatment. The degree of anemia may be a predominant risk factor for cognitive impairment in these ESRD patients. PMID:27167984

  7. Feasibility of Using Pseudo-Continuous Arterial Spin Labeling Perfusion in a Geriatric Population at 1.5 Tesla.

    Directory of Open Access Journals (Sweden)

    Sigurdur Sigurdsson

    Full Text Available To evaluate the feasibility of using pseudo-continuous arterial spin labeling (pCASL perfusion in a geriatric population at 1.5-Tesla.In 17 participants (mean age 78.8±1.63 years we assessed; 1 inter-session repeatability and reliability of resting state perfusion in 27 brain regions; 2 brain activation using finger-tapping as a means to evaluate the ability to detect flow differences; 3 reliability by comparing cerebral blood flow (CBF with pCASL to CBF with phase contrast (PC-MR.The CBF (mean±standard deviation (SD for the whole brain grey matter (GM was 40.6±8.4 and 41.4±8.7 ml/100g/min for the first and second scan respectively. The within-subject standard deviation (SDw, the repeatability index (RI and intra-class correlation coefficient (ICC across the 27 regions ranged from 1.1 to 7.9, 2.2 to 15.5 and 0.35 to 0.98 respectively. For whole brain GM the SDw, RI and ICC were 1.6, 3.2 and 0.96 respectively. The between-subject standard deviation (SDB was larger than the SDw for all regions. Comparison of CBF at rest and activation on a voxel level showed significantly higher perfusion during finger tapping in the motor- and somatosensory regions. The mean CBF for whole brain GM was 40.6±8.4 ml/100g/min at rest and 42.6±8.6 ml/100g/min during activation. Finally the reliability of pCASL against the reference standard of PC-MR was high (ICC = 0.80. The mean CBF for whole brain measured with PC-MRI was 54.3±10.1 ml/100g/min and 38.3±7.8 ml/100g/min with pCASL.The results demonstrate moderate to high levels of repeatability and reliability for most brain regions, comparable to what has been reported for younger populations. The performance of pCASL at 1.5-Tesla shows that region-specific perfusion measurements with this technique are feasible in studies of a geriatric population.

  8. [Abnormal cerebral blood flow distributions during the post-ictal phase of febrile status epilepticus in three pediatric patients measured by arterial spin labeling perfusion MRI].

    Science.gov (United States)

    Hirano, Keiko; Fukuda, Tokiko

    2016-05-01

    The ability to visualize brain perfusion is important for identifying epileptic foci. We present three pediatric cases showing asymmetrical cerebral blood flow (CBF) distributions during the post-ictal phase of febrile status epilepticus measured by arterial spin labeling (ASL) perfusion MRI. During the acute phase, regional CBF measurements in the areas considered including epileptic foci were higher than in the corresponding area of the contralateral hemisphere, though the exact quantitative value varied between cases. We could not identify the correct epileptogenic foci, because those ASL images were taken after the prolonged and extraordinary activation of neurons in the affected area. During the recovery phase, the differences reduced and the average regional CBF measurement was 54.6 ± 6.1 ml/100 g per minute, which was a little less than the number of previous ASL studies. ASL perfusion MRI imaging provides a method for evaluating regional CBF by using magnetically labeled arterial blood water as an endogenous tracer. With this technique, we can repeatedly evaluate both the brain structure and the level of perfusion at the same time. ASL is noninvasive and easily accessible, and therefore it could become a routine tool for assessment of perfusion in daily practice of pediatric neurology. PMID:27349086

  9. Multi-delay arterial spin labeling perfusion MRI in moyamoya disease-comparison with CT perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Rui [Chinese Academy of Sciences, State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Beijing (China); University of Chinese Academy of Sciences, Graduate School, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Los Angeles, CA (United States); Yu, Songlin [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); University of California Los Angeles, Department of Neurology, Los Angeles (United States); Alger, Jeffry R.; Wang, Danny J.J. [University of California Los Angeles, Department of Neurology, Los Angeles (United States); UCLA-Beijing Joint Center for Advanced Brain Imaging, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Los Angeles, CA (United States); Zuo, Zhentao; Wang, Bo [Chinese Academy of Sciences, State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Beijing (China); Chen, Juan [Beijing Hospital, Department of Radiology, Beijing (China); Wang, Rong; Zhao, Jizong [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); An, Jing [Siemens Shenzhen Magnetic Resonance Ltd, Shenzhen (China); Xue, Rong [Chinese Academy of Sciences, State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Los Angeles, CA (United States)

    2014-05-15

    To present a multi-delay pseudo-continuous ASL (pCASL) protocol that offers simultaneous measurements of cerebral blood flow (CBF) and arterial transit time (ATT), and to study correlations between multi-delay pCASL and CT perfusion in moyamoya disease. A 4 post-labeling delay (PLD) pCASL protocol was applied on 17 patients with moyamoya disease who also underwent CT perfusion imaging. ATT was estimated using the multi-delay protocol and included in the calculation of CBF. ASL and CT perfusion images were rated for lesion severity/conspicuity. Pearson correlation coefficients were calculated across voxels between the two modalities in grey and white matter of each subject respectively and between normalized mean values of ASL and CT perfusion measures in major vascular territories. Significant associations between ASL and CT perfusion were detected using subjective ratings, voxel-wise analysis in grey and white matter and region of interest (ROI)-based analysis of normalized mean perfusion. The correlation between ASL CBF and CT perfusion was improved using the multi-delay pCASL protocol compared to CBF acquired at a single PLD of 2 s (P < 0.05). There is a correlation between perfusion data from ASL and CT perfusion imaging in patients with moyamoya disease. Multi-delay ASL can improve CBF quantification, which could be a prognostic imaging biomarker in patients with moyamoya disease. (orig.)

  10. Multi-delay arterial spin labeling perfusion MRI in moyamoya disease-comparison with CT perfusion imaging

    International Nuclear Information System (INIS)

    To present a multi-delay pseudo-continuous ASL (pCASL) protocol that offers simultaneous measurements of cerebral blood flow (CBF) and arterial transit time (ATT), and to study correlations between multi-delay pCASL and CT perfusion in moyamoya disease. A 4 post-labeling delay (PLD) pCASL protocol was applied on 17 patients with moyamoya disease who also underwent CT perfusion imaging. ATT was estimated using the multi-delay protocol and included in the calculation of CBF. ASL and CT perfusion images were rated for lesion severity/conspicuity. Pearson correlation coefficients were calculated across voxels between the two modalities in grey and white matter of each subject respectively and between normalized mean values of ASL and CT perfusion measures in major vascular territories. Significant associations between ASL and CT perfusion were detected using subjective ratings, voxel-wise analysis in grey and white matter and region of interest (ROI)-based analysis of normalized mean perfusion. The correlation between ASL CBF and CT perfusion was improved using the multi-delay pCASL protocol compared to CBF acquired at a single PLD of 2 s (P < 0.05). There is a correlation between perfusion data from ASL and CT perfusion imaging in patients with moyamoya disease. Multi-delay ASL can improve CBF quantification, which could be a prognostic imaging biomarker in patients with moyamoya disease. (orig.)

  11. Thyroid perfusion imaging as a diagnostic tool in Graves' disease. Arterial spin labeling magnetic resonance imaging vs. colour-coded Doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Muessig, K. [University Hospital of Duesseldorf (Germany). Dept. of Metabolic Diseases; Leibniz Center for Diabetes Research, Duesseldorf (Germany). Inst. for Clinical Diabetology; University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Schraml, C.; Schwenzer, N.F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology; Rietig, R.; Balletshofer, B. [University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Martirosian, P.; Haering, H.U.; Schick, F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; Claussen, C.D. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology

    2012-12-15

    Purpose: Though increased thyroid perfusion assessed by colour-coded Doppler ultrasound (CDUS) is characteristic of Graves' disease (GD), sometimes perfusion assessment by CDUS is not possible. In these cases, arterial spin labelling (ASL), a novel magnetic resonance imaging (MRI) technique allowing non-invasive thyroid perfusion quantification, may have additional diagnostic value. We aimed to evaluate the potential of ASL-MRI for assessment of increased blood perfusion in patients with GD compared to CDUS. Materials and Methods: Thyroid perfusion was measured by CDUS (volume flow rate calculated from pulsed wave Doppler signals and vessel diameter) and ASL-MRI at 1.5 T in 7 patients with GD and 10 healthy controls. Results: In patients with GD, average perfusion in both thyroid lobes was markedly increased compared to controls. Both techniques applied for volume related perfusion as well as absolute volume flow in thyroid feeding vessels provided similar results (all p = 0.0008). Using a cut-off value of 22 ml/min for the volume flow rate assessed by CDUS in the four feeding vessels allowed discrimination between patients with GD and controls in all cases. After adjusting thyroid perfusion for the differences in organ volume, both CDUS and ASL revealed also complete discrimination between health and disease. Conclusion: Thyroid perfusion measurement by ASL-MRI reliably discriminate GD from normal thyroid glands. In patients in whom thyroid arteries cannot be depicted by CDUS for technical or anatomical reasons, ASL-MRI may have additional diagnostic value. (orig.)

  12. Renal blood flow using arterial spin labelling MRI and calculated filtration fraction in healthy adult kidney donors pre-nephrectomy and post-nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Cutajar, Marica; Clark, Christopher A.; Gordon, Isky [University College London, Imaging and Biophysics Unit, Institute of Child Health, London (United Kingdom); Hilton, Rachel; Olsburgh, Jonathon [Renal Unit, Guy' s and St Thomas' NHS Foundation Trust, London (United Kingdom); Marks, Stephen D. [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Paediatric Nephrology, London (United Kingdom); Thomas, David L. [University College London, Department of Brain Repair and Rehabilitation, Institute of Neurology, London (United Kingdom); Banks, Tina [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Radiology, London (United Kingdom)

    2015-08-15

    Renal plasma flow (RPF) (derived from renal blood flow, RBF) and glomerular filtration rate (GFR) allow the determination of the filtration fraction (FF), which may have a role as a non-invasive renal biomarker. This is a hypothesis-generating pilot study assessing the effect of nephrectomy on renal function in healthy kidney donors. Eight living kidney donors underwent arterial spin labelling (ASL) magnetic resonance imaging (MRI) and GFR measurement prior to and 1 year after nephrectomy. Chromium-51 labelled ethylenediamine tetraacetic acid ({sup 51}Cr-EDTA) with multi-blood sampling was undertaken and GFR calculated. The RBF and GFR obtained were used to calculate FF. All donors showed an increase in single kidney GFR of 24 - 75 %, and all but two showed an increase in FF (-7 to +52 %) after nephrectomy. The increase in RBF, and hence RPF, post-nephrectomy was not as great as the increase in GFR in seven out of eight donors. As with any pilot study, the small number of donors and their relatively narrow age range are potential limiting factors. The ability to measure RBF, and hence RPF, non-invasively, coupled with GFR measurement, allows calculation of FF, a biomarker that might provide a sensitive indicator of loss of renal reserve in potential donors. (orig.)

  13. Renal blood flow using arterial spin labelling MRI and calculated filtration fraction in healthy adult kidney donors pre-nephrectomy and post-nephrectomy

    International Nuclear Information System (INIS)

    Renal plasma flow (RPF) (derived from renal blood flow, RBF) and glomerular filtration rate (GFR) allow the determination of the filtration fraction (FF), which may have a role as a non-invasive renal biomarker. This is a hypothesis-generating pilot study assessing the effect of nephrectomy on renal function in healthy kidney donors. Eight living kidney donors underwent arterial spin labelling (ASL) magnetic resonance imaging (MRI) and GFR measurement prior to and 1 year after nephrectomy. Chromium-51 labelled ethylenediamine tetraacetic acid (51Cr-EDTA) with multi-blood sampling was undertaken and GFR calculated. The RBF and GFR obtained were used to calculate FF. All donors showed an increase in single kidney GFR of 24 - 75 %, and all but two showed an increase in FF (-7 to +52 %) after nephrectomy. The increase in RBF, and hence RPF, post-nephrectomy was not as great as the increase in GFR in seven out of eight donors. As with any pilot study, the small number of donors and their relatively narrow age range are potential limiting factors. The ability to measure RBF, and hence RPF, non-invasively, coupled with GFR measurement, allows calculation of FF, a biomarker that might provide a sensitive indicator of loss of renal reserve in potential donors. (orig.)

  14. Pattern of cerebral hyperperfusion in Alzheimer's disease and amnestic mild cognitive impairment using voxel-based analysis of 3D arterial spin-labeling imaging: initial experience

    Directory of Open Access Journals (Sweden)

    Ding B

    2014-03-01

    Full Text Available Bei Ding,1 Hua-wei Ling,1 Yong Zhang,2 Juan Huang,1 Huan Zhang,1 Tao Wang,3 Fu Hua Yan11Department of Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, 2Applied Science Laboratory, GE Healthcare, 3Department of Gerontology, Shanghai Mental Health Center, Shanghai, People's Republic of ChinaPurpose: A three-dimensional (3D continuous pulse arterial spin labeling (ASL technique was used to investigate cerebral blood flow (CBF changes in patients with Alzheimer's disease (AD, amnestic mild cognitive impairment (aMCI, and age- and sex-matched healthy controls.Materials and methods: Three groups were recruited for comparison, 24 AD patients, 17 MCI patients, and 21 age- and sex-matched control subjects. Three-dimensional ASL scans covering the entire brain were acquired with a 3.0 T magnetic resonance scanner. Spatial processing was performed with statistical parametric mapping 8. A second-level one-way analysis of variance analysis (threshold at P<0.05 was performed on the preprocessed ASL data. An average whole-brain CBF for each subject was also included as group-level covariates for the perfusion data, to control for individual CBF variations.Results: Significantly increased CBF was detected in bilateral frontal lobes and right temporal subgyral regions in aMCI compared with controls. When comparing AD with aMCI, the major hyperperfusion regions were the right limbic lobe and basal ganglia regions, including the putamen, caudate, lentiform nucleus, and thalamus, and hypoperfusion was found in the left medial frontal lobe, parietal cortex, the right middle temporo-occipital lobe, and particularly, the left anterior cingulate gyrus. We also found decreased CBF in the bilateral temporo-parieto-occipital cortices and left limbic lobe in AD patients, relative to the control group. aMCI subjects showed decreased blood flow in the left occipital lobe, bilateral inferior temporal cortex, and right middle temporal cortex

  15. Optimization of 4D vessel-selective arterial spin labeling angiography using balanced steady-state free precession and vessel-encoding.

    Science.gov (United States)

    Okell, Thomas W; Schmitt, Peter; Bi, Xiaoming; Chappell, Michael A; Tijssen, Rob H N; Sheerin, Fintan; Miller, Karla L; Jezzard, Peter

    2016-06-01

    Vessel-selective dynamic angiograms provide a wealth of useful information about the anatomical and functional status of arteries, including information about collateral flow and blood supply to lesions. Conventional x-ray techniques are invasive and carry some risks to the patient, so non-invasive alternatives are desirable. Previously, non-contrast dynamic MRI angiograms based on arterial spin labeling (ASL) have been demonstrated using both spoiled gradient echo (SPGR) and balanced steady-state free precession (bSSFP) readout modules, but no direct comparison has been made, and bSSFP optimization over a long readout period has not been fully explored. In this study bSSFP and SPGR are theoretically and experimentally compared for dynamic ASL angiography. Unlike SPGR, bSSFP was found to have a very low ASL signal attenuation rate, even when a relatively large flip angle and short repetition time were used, leading to a threefold improvement in the measured signal-to-noise ratio (SNR) efficiency compared with SPGR. For vessel-selective applications, SNR efficiency can be further improved over single-artery labeling methods by using a vessel-encoded pseudo-continuous ASL (VEPCASL) approach. The combination of a VEPCASL preparation with a time-resolved bSSFP readout allowed the generation of four-dimensional (4D; time-resolved three-dimensional, 3D) vessel-selective cerebral angiograms in healthy volunteers with 59 ms temporal resolution. Good quality 4D angiograms were obtained in all subjects, providing comparable structural information to 3D time-of-flight images, as well as dynamic information and vessel selectivity, which was shown to be high. A rapid 1.5 min dynamic two-dimensional version of the sequence yielded similar image features and would be suitable for a busy clinical protocol. Preliminary experiments with bSSFP that included the extracranial vessels showed signal loss in regions of poor magnetic field homogeneity. However, for intracranial vessel

  16. Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition.

    Science.gov (United States)

    Wu, Huimin; Block, Walter F; Turski, Patrick A; Mistretta, Charles A; Johnson, Kevin M

    2013-03-01

    Pseudocontinuous arterial spin labeling (PCASL) can be used to generate noncontrast magnetic resonance angiograms of the cerebrovascular structures. Previously described PCASL-based angiography techniques were limited to two-dimensional projection images or relatively low-resolution three-dimensional (3D) imaging due to long acquisition time. This work proposes a new PCASL-based 3D magnetic resonance angiography method that uses an accelerated 3D radial acquisition technique (VIPR, spoiled gradient echo) as the readout. Benefiting from the sparsity provided by PCASL and noise-like artifacts of VIPR, this new method is able to obtain submillimeter 3D isotropic resolution and whole head coverage with a 8-min scan. Intracranial angiography feasibility studies in healthy (N = 5) and diseased (N = 5) subjects show reduced saturation artifacts in PCASL-VIPR compared with a standard time-of-flight protocol. These initial results show great promise for PCASL-VIPR for static, dynamic, and vessel selective 3D intracranial angiography. PMID:22532423

  17. Evaluation of the degree of arteriovenous shunting in intracranial arteriovenous malformations using pseudo-continuous arterial spin labeling magnetic resonance imaging

    International Nuclear Information System (INIS)

    Intracranial arteriovenous malformations (AVMs) display venous signals on arterial spin labeling (ASL) magnetic resonance (MR) imaging due to the presence of arteriovenous shunting. Our aim was to quantitatively correlate AVM signal intensity on ASL with the degree of arteriovenous shunting estimated on digital subtraction angiography (DSA) in AVMs. MR imaging including pseudo-continuous ASL at 3 T and DSA were obtained on the same day in 40 patients with intracranial AVMs. Two reviewers assessed the nidus and venous signal intensities on ASL images to determine the presence of arteriovenous shunting. Interobserver agreement on ASL between the reviewers was determined. ASL signal intensity of the AVM lesion was correlated with AVM size and the time difference between normal and AVM venous transit times measured from the DSA images. Interobserver agreement between two reviewers for nidus and venous signal intensities was excellent (κ = 0.80 and 1.0, respectively). Interobserver agreement regarding the presence of arteriovenous shunting was perfect (κ = 1.0). AVM signal intensity showed a positive relationship with the time difference between normal and AVM venous transit times (r = 0.638, P < 0.001). AVM signal intensity also demonstrated a positive relationship with AVM size (r = 0.561, P < 0.001). AVM signal intensity on ASL in patients with AVM correlates well with the degree of early vein opacification on DSA, which corresponds to the degree of arteriovenous shunting. (orig.)

  18. Evaluation of the degree of arteriovenous shunting in intracranial arteriovenous malformations using pseudo-continuous arterial spin labeling magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sunwoo, Leonard; Park, Sun-Won [Seoul Metropolitan Government - Seoul National University Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Sohn, Chul-Ho; Yun, Tae Jin; Choi, Seung Hong; Cho, Young Dae; Kim, Ji-hoon; Han, Moon Hee [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Lee, Jong Young [Kangdong Sacred Heart Hospital, Department of Neurosurgery, Seoul (Korea, Republic of); Yi, Kyung Sik [Chungbuk National University Hospital, Department of Radiology, Cheongju (Korea, Republic of); Paek, Sun Ha; Kim, Yong Hwy; Kim, Jin Wook; Chung, Hyun-Tai; Kim, Dong Gyu [Seoul National University Hospital, Department of Neurosurgery, Seoul (Korea, Republic of)

    2015-08-15

    Intracranial arteriovenous malformations (AVMs) display venous signals on arterial spin labeling (ASL) magnetic resonance (MR) imaging due to the presence of arteriovenous shunting. Our aim was to quantitatively correlate AVM signal intensity on ASL with the degree of arteriovenous shunting estimated on digital subtraction angiography (DSA) in AVMs. MR imaging including pseudo-continuous ASL at 3 T and DSA were obtained on the same day in 40 patients with intracranial AVMs. Two reviewers assessed the nidus and venous signal intensities on ASL images to determine the presence of arteriovenous shunting. Interobserver agreement on ASL between the reviewers was determined. ASL signal intensity of the AVM lesion was correlated with AVM size and the time difference between normal and AVM venous transit times measured from the DSA images. Interobserver agreement between two reviewers for nidus and venous signal intensities was excellent (κ = 0.80 and 1.0, respectively). Interobserver agreement regarding the presence of arteriovenous shunting was perfect (κ = 1.0). AVM signal intensity showed a positive relationship with the time difference between normal and AVM venous transit times (r = 0.638, P < 0.001). AVM signal intensity also demonstrated a positive relationship with AVM size (r = 0.561, P < 0.001). AVM signal intensity on ASL in patients with AVM correlates well with the degree of early vein opacification on DSA, which corresponds to the degree of arteriovenous shunting. (orig.)

  19. Inter-scanner reliability and reproducibility of three dimensional pseudo-continuous arterial spin-labeling MR perfusion of posterior circulation territory in healthy adults

    International Nuclear Information System (INIS)

    Objective: To assess the inter-scanner reliability and reproducibility of 3D whole-brain pseudo-continuous arterial spin labeling (pCASL) of posterior circulation territory in healthy adults. Methods: Twelve healthy subjects were scanned twice on two different 3.0 T MR scanners with 3D whole-brain pCASL technique. Intervals between tests were among 10-15 days. The ASL data with two post labeling delay time (PLD) of 1.5 and 2.5 seconds were acquired during every scanning. The cerebral blood flow (CBF) values of posterior circulation territory including cerebellum, midbrain, pons, medulla oblongata, thalamus and occipital lobe were extracted based on SPM technique for comparison. The inter-scanner reliability and reproducibility were evaluated with the intraclass correlation coefficient (ICC) and Bland-Altman plot. Results: The CBF values of posterior circulation territory were 36-47 ml · min-1 ·100 g-1 (PLD =1.5 s) and 36-46 ml · min-1 · 100 g-1 (PLD =2.5 s). Comparing the data between the two tests, the ICC was 0.851 at PLD =1.5 s and 0.914 at PLD =2.5 s. The Bland-Altman showed the reproducibility at PLD =2.5 s was better than that at PLD =1.5 s. Conclusions: The 3D whole-brain pCASL technique is available for measuring the CBF at posterior circulation territory with high reliability and reproducibility especially using longer PLD. It can be used for MR multicenter study on blood flow of posterior circulation territory. (authors)

  20. Arterial spin-labeling MR imaging in moyamoya disease compared with clinical assessments and other MR imaging finings

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Tomoyuki, E-mail: tnogucci@radiol.med.kyushu-u.ac.jp [Department of Radiology, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Kawashima, Masatou [Department of Neurosurgery, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Nishihara, Masashi; Hirai, Tetsuyoshi [Department of Radiology, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Matsushima, Toshio [Department of Neurosurgery, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Irie, Hiroyuki [Department of Radiology, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan)

    2013-12-01

    Purpose: Our purpose was to identify the causal factors for the perfusion distribution obtained with ASL-MRI by comparing ASL-MRI with clinical information and other MRI findings in moyamoya disease. Methods: Seventy-one patients with moyamoya disease underwent ASL-MRI and other MRI, including fluid-attenuated inversion recovery imaging (FLAIR) and three-dimensional time-of-flight magnetic resonance angiography (MRA) on 3.0-Tesla MRI system. Cerebral blood flow (CBF) values (ASL values) for the cerebral hemispheres (142 sides) were measured on CBF maps generated by ASL-MRI. Relationships between the ASL values and the following 9 factors were assessed: sex, family history, revascularization surgery, age at MR exam, age at onset, the steno-occlusive severity on MRA (MRA score), degree of basal collaterals, degree of leptomeningeal high signal intensity seen on FLAIR, and size of ischemic or hemorrhagic cerebrovascular accident lesion (CVA score). Results: Patients with a family history had significantly higher ASL values than those without such a history. There were significant negative correlations between ASL values and age at MR exam, MRA score, and CVA score. Conclusions: ASL-MRI may have cause-and-effect or mutual associations with family history, current patient age, size of CVA lesion, and intracranial arterial steno-occlusive severity in Moyamoya disease.

  1. Assessment of tumor blood flow and its correlation with histopathologic features in skull base meningiomas and schwannomas by using pseudo-continuous arterial spin labeling images

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tatsuya, E-mail: yamatatu_01eik@yahoo.co.jp [Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui (Japan); Takeuchi, Hiroaki, E-mail: takeu@u-fukui.ac.jp [Department of Neurosurgery, Faculty of Medical Sciences, University of Fukui, Fukui (Japan); Kinoshita, Kazuyuki, E-mail: kkino@u-fukui.ac.jp [Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui (Japan); Kosaka, Nobuyuki, E-mail: nkosaka@u-fukui.ac.jp [Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui (Japan); Kimura, Hirohiko, E-mail: kimura@u-fukui.ac.jp [Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui (Japan)

    2014-05-15

    Objective: We aimed to investigate whether pseudo-continuous arterial spin labeling (pcASL)-MRI can adequately evaluate tumor perfusion even if the tumors are located in the skull base region and evaluate the correlation between tumor blood flow (TBF) and the histopathologic features of skull base meningiomas and schwannomas. Materials and methods: We enrolled 31 patients with skull base meningioma (n = 14) and schwannoma (n = 17) who underwent surgical resection. TBF was calculated from pcASL. Tissue sections were stained with CD34 to evaluate microvessel area (MVA). TBF and MVA ratio were compared between meningiomas and schwannomas using Mann–Whitney U-test. The correlations between MVA ratio and TBF were evaluated in each tumor by using single linear regression analysis and Spearman's rank correlation coefficients (r{sub s}). Results: MVA ratio and TBF were significantly higher in meningioma than in schwannoma (both p < 0.01). Correlation analyses revealed significant positive correlations between MVA ratio and both mean and max TBF for meningiomas (r{sub s} = 0.89, 0.81, both p < 0.01). There was a weak positive correlation between MVA ratio and mean TBF for schwannomas (r{sub s} = 0.43, p = 0.04). However, no significant correlation was found between MVA ratio and max TBF for schwannoma. Conclusions: pcASL-MRI is useful for evaluating tumor perfusion even if the tumors are located in the skull base region. Moreover, pcASL-TBF was significantly higher in most meningiomas compared to schwannomas, which can help in the differential diagnosis of the 2 tumor types even without the use of contrast material.

  2. Astrocytic tumour grading: a comparative study of three-dimensional pseudocontinuous arterial spin labelling, dynamic susceptibility contrast-enhanced perfusion-weighted imaging, and diffusion-weighted imaging

    International Nuclear Information System (INIS)

    We hypothesized that three-dimensional pseudocontinuous arterial spin labelling (pCASL) may have similar efficacy in astrocytic tumour grading as dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI), and the grading accuracy may be further improved when combined with apparent diffusion coefficient (ADC) values. Forty-three patients with astrocytic tumours were studied using diffusion weighted imaging (DWI), pCASL, and DSC-PWI. Histograms of ADC and normalized tumour cerebral blood flow values (nCBF on pCASL and nrCBF on DSC-PWI) were measured and analyzed. The mean 10 % ADC value was the DWI parameter that provided the best differentiation between low-grade astrocytoma (LGA) and high-grade astrocytoma (HGA). The nCBF and nrCBF (1.810 ± 0.979 and 2.070 ± 1.048) in LGA were significantly lower than those (4.505 ± 2.270 and 5.922 ± 2.630) in HGA. For differentiation between LGA and HGA, the cutoff values of 0.764 x 10-3 mm2/s for mean 10 % ADC, 2.374 for nCBF, and 3.464 for nrCBF provided the optimal accuracy (74.4 %, 86.1 %, and 88.6 %, respectively). Combining the ADC values with nCBF or nrCBF could further improve the grading accuracy to 97.7 % or 95.3 %, respectively. pCASL is an alternative to DSC-PWI for astrocytic tumour grading. The combination of DWI and contrast-free pCASL offers a valuable choice in patients with risk factors. (orig.)

  3. Changes in cerebral blood flow after transjugular intrahepatic portosystemic shunt can help predict the development of hepatic encephalopathy: An arterial spin labeling MR study

    International Nuclear Information System (INIS)

    Background and purpose: Cerebral blood flow (CBF) changes after transjugular intrahepatic portosystemic shunt (TIPS) are still unclear. Our aim is to assess the TIPS-induced CBF changes and their potential clinical significance using the arterial spin labeling (ASL) perfusion magnetic resonance imaging. Materials and methods: Nine cirrhotic patients underwent ASL 1–8 days before and 4–7 days after TIPS. CBF was calculated at each voxel and mean CBF values were computed in the whole brain, gray matter and white matter. Changes of CBFs before and after TIPS were compared by paired t-test. Results: Voxel-wise results showed CBF diffusely increased in patients after TIPS, but no region with significant decrease in CBF was found, nor was any significant mean CBF difference detected in the whole brain, gray matter and white matter. Six patients out of nine showed a global CBF increase of 9–39%; one patient presented a global CBF decrease of 6%; another two showed a global CBF decrease of 16% and 31% respectively. Follow-up studies showed that the two patients with greatly decreased global CBF suffered from multiple episodes of overt hepatic encephalopathy (OHE) after TIPS and one died of OHE. Conclusions: CBF derived from noninvasive ASL MRI could be used as a useful biomarker to predict the development of OHE through consecutively tracking CBF changes in patients with inserted TIPS. Increased CBFs in many cortical regions could be common effects of the TIPS procedure, while decreased global CBF following TIPS might indicate the development of OHE.

  4. Operator-bias-free comparison of quantitative perfusion maps acquired with pulsed-continuous arterial spin labeling and single-photon-emission computed tomography

    International Nuclear Information System (INIS)

    We compared the regional cerebral blood flow (rCBF) obtained by pulsed continuous arterial spin labeling (pCASL) and iodine-123-N-isopropyl-p-iodoamphetamine (IMP) single photon emission computed tomography (SPECT) using 3-dimensional stereotactic region-of-interest (ROI) software for automated definition of ROIs in anatomic regions of the brain. Thirteen patients with cerebrovascular occlusive disease and three with transient ischemic attacks underwent pCASL and IMP SPECT imaging. We compared rCBF values of each anatomic region and calculated the correlation coefficients between pCASL and IMP SPECT. We also calculated the asymmetry index (AI) using ROIs in contralateral regions of the hemispheres. The rCBF values calculated from pCASL and IMP SPECT were comparable in most segments, but rCBF in the thalamus (P < 0.0001) and hippocampus (P=0.0006) was significantly higher measured by pCASL than IMP SPECT. The correlation of rCBF between pCASL and IMP SPECT in the affected hemisphere (r=0.50) tended to be lower than that in the normal hemisphere (r=0.59), but not significantly different (P=0.25). Moreover, there was a fixed bias for underestimation of rCBF by pCASL (P=0.0047) in the affected hemisphere. The calculated AI showed a significant relationship between methods (r=0.79, P < 0.0001). The rCBF obtained by pCASL had positive relationships with IMP SPECT. However, it should be considered that pCASL tends to have a weak relationship with IMP SPECT in some normal regions and regions affected by cerebrovascular occlusive disease. (author)

  5. Non-invasive assessment of intratumoral vascularity using arterial spin labeling: A comparison to susceptibility-weighted imaging for the differentiation of primary cerebral lymphoma and glioblastoma

    International Nuclear Information System (INIS)

    Using conventional MRI methods, the differentiation of primary cerebral lymphomas (PCNSL) and other primary brain tumors, such as glioblastomas, is difficult due to overlapping imaging characteristics. This study was designed to discriminate tumor entities using normalized vascular intratumoral signal intensity values (nVITS) obtained from pulsed arterial spin labeling (PASL), combined with intratumoral susceptibility signals (ITSS) from susceptibility-weighted imaging (SWI). Thirty consecutive patients with glioblastoma (n = 22) and PCNSL (n = 8), histologically classified according to the WHO brain tumor classification, were included. MRIs were acquired on a 3 T scanner, and included PASL and SWI sequences. nVITS was defined by the signal intensity ratio between the tumor and the contralateral normal brain tissue, as obtained by PASL images. ITSS was determined as intratumoral low signal intensity structures detected on SWI sequences and were divided into four different grades. Potential differences in the nVITS and ITSS between glioblastomas and PCNSLs were revealed using statistical testing. To determine sensitivity, specificity, and diagnostic accuracy, as well as an optimum cut-off value for the differentiation of PCNSL and glioblastoma, a receiver operating characteristic analysis was used. We found that nVITS (p = 0.011) and ITSS (p = 0.001) values were significantly higher in glioblastoma than in PCNSL. The optimal cut-off value for nVITS was 1.41 and 1.5 for ITSS, with a sensitivity, specificity, and accuracy of more than 95%. These findings indicate that nVITS values have a comparable diagnostic accuracy to ITSS values in differentiating glioblastoma and PCNSL, offering a completely non-invasive and fast assessment of tumoral vascularity in a clinical setting

  6. Non-invasive assessment of intratumoral vascularity using arterial spin labeling: A comparison to susceptibility-weighted imaging for the differentiation of primary cerebral lymphoma and glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Furtner, J., E-mail: julia.furtner@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Schöpf, V., E-mail: veronika.schoepf@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Preusser, M., E-mail: matthias.preusser@meduniwien.ac.at [Department of Medicine I, Division of Oncology, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Asenbaum, U., E-mail: ulrika.asenbaum@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Woitek, R., E-mail: ramona.woitek@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Wöhrer, A., E-mail: adelheid.woehrer@meduniwien.ac.at [Institute of Neurology, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Hainfellner, J.A., E-mail: johannes.hainfellner@meduniwien.ac.at [Institute of Neurology, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Wolfsberger, S., E-mail: stefan.wolfsberger@meduniwien.ac.at [Department of Neurosurgery, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Prayer, D., E-mail: daniela.prayer@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria)

    2014-05-15

    Using conventional MRI methods, the differentiation of primary cerebral lymphomas (PCNSL) and other primary brain tumors, such as glioblastomas, is difficult due to overlapping imaging characteristics. This study was designed to discriminate tumor entities using normalized vascular intratumoral signal intensity values (nVITS) obtained from pulsed arterial spin labeling (PASL), combined with intratumoral susceptibility signals (ITSS) from susceptibility-weighted imaging (SWI). Thirty consecutive patients with glioblastoma (n = 22) and PCNSL (n = 8), histologically classified according to the WHO brain tumor classification, were included. MRIs were acquired on a 3 T scanner, and included PASL and SWI sequences. nVITS was defined by the signal intensity ratio between the tumor and the contralateral normal brain tissue, as obtained by PASL images. ITSS was determined as intratumoral low signal intensity structures detected on SWI sequences and were divided into four different grades. Potential differences in the nVITS and ITSS between glioblastomas and PCNSLs were revealed using statistical testing. To determine sensitivity, specificity, and diagnostic accuracy, as well as an optimum cut-off value for the differentiation of PCNSL and glioblastoma, a receiver operating characteristic analysis was used. We found that nVITS (p = 0.011) and ITSS (p = 0.001) values were significantly higher in glioblastoma than in PCNSL. The optimal cut-off value for nVITS was 1.41 and 1.5 for ITSS, with a sensitivity, specificity, and accuracy of more than 95%. These findings indicate that nVITS values have a comparable diagnostic accuracy to ITSS values in differentiating glioblastoma and PCNSL, offering a completely non-invasive and fast assessment of tumoral vascularity in a clinical setting.

  7. Altered cerebral blood flow one month after systemic chemotherapy for breast cancer: a prospective study using pulsed arterial spin labeling MRI perfusion.

    Directory of Open Access Journals (Sweden)

    Kelly N H Nudelman

    Full Text Available Cerebral structural and functional alterations have been reported after chemotherapy for non-CNS cancers, yet the causative mechanism behind these changes remains unclear. This study employed a novel, non-invasive, MRI-based neuroimaging measure to provide the first direct longitudinal measurement of resting cerebral perfusion in breast cancer patients, which was tested for association with changes in cognitive function and gray matter density. Perfusion was measured using pulsed arterial spin labeling MRI in women with breast cancer treated with (N = 27 or without (N = 26 chemotherapy and matched healthy controls (N = 26 after surgery before other treatments (baseline, and one month after chemotherapy completion or yoked intervals. Voxel-based analysis was employed to assess perfusion in gray matter; changes were examined in relation to overall neuropsychological test performance and frontal gray matter density changes measured by structural MRI. Baseline perfusion was not significantly different across groups. Unlike control groups, chemotherapy-treated patients demonstrated significantly increased perfusion post-treatment relative to baseline, which was statistically significant relative to controls in the right precentral gyrus. This perfusion increase was negatively correlated with baseline overall neuropsychological performance, but was not associated with frontal gray matter density reduction. However, decreased frontal gray matter density was associated with decreased perfusion in bilateral frontal and parietal lobes in the chemotherapy-treated group. These findings indicate that chemotherapy is associated with alterations in cerebral perfusion which are both related to and independent of gray matter changes. This pattern of results suggests the involvement of multiple mechanisms of chemotherapy-induced cognitive dysfunction. Additionally, lower baseline cognitive function may be a risk factor for treatment

  8. Astrocytic tumour grading: a comparative study of three-dimensional pseudocontinuous arterial spin labelling, dynamic susceptibility contrast-enhanced perfusion-weighted imaging, and diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Hua-Feng [302 Hospital of Chinese People' s Liberation Army, Department of Radiology, Beijing (China); Chen, Zhi-Ye; Wang, Yu-Lin; Wang, Yan; Ma, Lin [People' s Liberation Army General Hospital, Department of Radiology, Beijing (China); Lou, Xin [People' s Liberation Army General Hospital, Department of Radiology, Beijing (China); University of California, Department of Neurology, Los Angeles, CA (United States); Gui, Qiu-Ping [People' s Liberation Army General Hospital, Department of Pathology, Beijing (China); Shi, Kai-Ning; Zhou, Zhen-Yu; Zheng, Dan-Dan [General Electric Healthcare (China) Co., Ltd., Beijing; Wang, Danny J.J. [University of California, Department of Neurology, Los Angeles, CA (United States)

    2015-12-15

    We hypothesized that three-dimensional pseudocontinuous arterial spin labelling (pCASL) may have similar efficacy in astrocytic tumour grading as dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI), and the grading accuracy may be further improved when combined with apparent diffusion coefficient (ADC) values. Forty-three patients with astrocytic tumours were studied using diffusion weighted imaging (DWI), pCASL, and DSC-PWI. Histograms of ADC and normalized tumour cerebral blood flow values (nCBF on pCASL and nrCBF on DSC-PWI) were measured and analyzed. The mean 10 % ADC value was the DWI parameter that provided the best differentiation between low-grade astrocytoma (LGA) and high-grade astrocytoma (HGA). The nCBF and nrCBF (1.810 ± 0.979 and 2.070 ± 1.048) in LGA were significantly lower than those (4.505 ± 2.270 and 5.922 ± 2.630) in HGA. For differentiation between LGA and HGA, the cutoff values of 0.764 x 10{sup -3} mm{sup 2}/s for mean 10 % ADC, 2.374 for nCBF, and 3.464 for nrCBF provided the optimal accuracy (74.4 %, 86.1 %, and 88.6 %, respectively). Combining the ADC values with nCBF or nrCBF could further improve the grading accuracy to 97.7 % or 95.3 %, respectively. pCASL is an alternative to DSC-PWI for astrocytic tumour grading. The combination of DWI and contrast-free pCASL offers a valuable choice in patients with risk factors. (orig.)

  9. Cerebral blood flow measured by arterial-spin labeling MRI: A useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis

    International Nuclear Information System (INIS)

    Purpose: To investigate the role of arterial-spin labeling (ASL) MRI to non-invasively characterize the patterns of cerebral blood flow (CBF) changes in cirrhotic patients and to assess the potential of ASL MRI to characterize minimal hepatic encephalopathy (MHE). Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Thirty six cirrhosis patients without overt hepatic encephalopathy (16 MHE patients and 20 non hepatic encephalopathy (non-HE) patients) and 25 controls underwent ASL MRI, and CBF was measured for each subject. One-way ANOCOVA test with age and gender as covariences was used to compare CBF difference among three groups, and post hoc analysis was performed between each two groups. Region-based correlation analysis was applied between Child–Pugh score, venous blood ammonia level, neuropsychological tests and CBF values in cirrhosis patients. Receiver operator characteristic (ROC) analysis was used for assessing CBF measurements in ASL MRI to differentiate MHE from non-HE patients. Results: The gray matter CBF of MHE patients (71.09 ± 11.88 mL min−1 100 g−1) was significantly higher than that of non-HE patients (55.28 ± 12.30 mL min−1 100 g−1, P < 0.01) and controls (52.09 ± 9.27 mL min−1 100 g−1, P < 0.001). Voxel-wise ANOCOVA results showed that CBFs were significantly different among three groups in multiple gray matter areas (P < 0.05, Bonferroni corrected). Post hoc comparisons showed that CBF of these brain regions was increased in MHE patients compared with controls and non-HE patients (P < 0.05, Bonferroni corrected). CBF of the right putamen was of the highest sensitivity (93.8%) and moderate specificity (75.0%) for characterization of MHE when using the cutoff value of 50.57 mL min−1 100 g−1. CBFs in the bilateral median cingulate gyri, left supramarginal gyrus, right angular gyrus, right heschl gyrus and right superior temporal gyrus

  10. Cerebral blood flow measured by arterial-spin labeling MRI: A useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Gang [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu, 210016 (China); Zhang, Long Jiang, E-mail: kevinzhlj@163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Zhong, Jianhui [Department of Imaging Sciences, University of Rochester School of Medicine and Dentistry, Box648, 601 Elmwood Avenue, Rochester, NY 14642-8648 (United States); Wang, Ze [Department of Psychiatry, Perelman School of Medicine, University of Pennsylvania, 3900 Chestnut St., Philadelphia, PA 19104 (United States); Qi, Rongfeng; Shi, Donghong [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Lu, Guang Ming, E-mail: cjr.luguangming@vip.163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China)

    2013-11-01

    Purpose: To investigate the role of arterial-spin labeling (ASL) MRI to non-invasively characterize the patterns of cerebral blood flow (CBF) changes in cirrhotic patients and to assess the potential of ASL MRI to characterize minimal hepatic encephalopathy (MHE). Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Thirty six cirrhosis patients without overt hepatic encephalopathy (16 MHE patients and 20 non hepatic encephalopathy (non-HE) patients) and 25 controls underwent ASL MRI, and CBF was measured for each subject. One-way ANOCOVA test with age and gender as covariences was used to compare CBF difference among three groups, and post hoc analysis was performed between each two groups. Region-based correlation analysis was applied between Child–Pugh score, venous blood ammonia level, neuropsychological tests and CBF values in cirrhosis patients. Receiver operator characteristic (ROC) analysis was used for assessing CBF measurements in ASL MRI to differentiate MHE from non-HE patients. Results: The gray matter CBF of MHE patients (71.09 ± 11.88 mL min{sup −1} 100 g{sup −1}) was significantly higher than that of non-HE patients (55.28 ± 12.30 mL min{sup −1} 100 g{sup −1}, P < 0.01) and controls (52.09 ± 9.27 mL min{sup −1} 100 g{sup −1}, P < 0.001). Voxel-wise ANOCOVA results showed that CBFs were significantly different among three groups in multiple gray matter areas (P < 0.05, Bonferroni corrected). Post hoc comparisons showed that CBF of these brain regions was increased in MHE patients compared with controls and non-HE patients (P < 0.05, Bonferroni corrected). CBF of the right putamen was of the highest sensitivity (93.8%) and moderate specificity (75.0%) for characterization of MHE when using the cutoff value of 50.57 mL min{sup −1} 100 g{sup −1}. CBFs in the bilateral median cingulate gyri, left supramarginal gyrus, right angular gyrus, right

  11. Positron emission tomography/magnetic resonance hybrid scanner imaging of cerebral blood flow using 15O-water positron emission tomography and arterial spin labeling magnetic resonance imaging in newborn piglets

    DEFF Research Database (Denmark)

    Andersen, Julie B; Henning, William S; Lindberg, Ulrich;

    2015-01-01

    arterial spin labeling (ASL) magnetic resonance imaging (MR) on a hybrid PET/MR in seven newborn piglets. Positron emission tomography was performed with IV injections of 20 MBq and 100 MBq (15)O-water to confirm CBF reliability at low activity. Cerebral blood flow was quantified using a one-tissue-compartment-model......Abnormality in cerebral blood flow (CBF) distribution can lead to hypoxic-ischemic cerebral damage in newborn infants. The aim of the study was to investigate minimally invasive approaches to measure CBF by comparing simultaneous (15)O-water positron emission tomography (PET) and single TI pulsed......, PET-IDIF overestimated CBF. Injected activity of 20 MBq (15)O-water had acceptable concordance with 100 MBq, without compromising image quality. Single TI ASL was questionable for regional CBF measurements. Global ASL CBF and PET CBF were congruent during baseline but not during hyperperfusion....

  12. Vessel encoded arterial spin labeling with cerebral perfusion: preliminary study%血管编码动脉自旋标记MR脑灌注成像初步研究

    Institute of Scientific and Technical Information of China (English)

    吴冰; 蒋学祥; 方竞; 王晶; 郭佳; 章蓓茹; 肖江喜; 谢晟; Eric C.Wong; 张珏; 王霄英

    2008-01-01

    目的 初步应用血管编码动脉自旋标记MR脑灌注成像技术选择件标记双侧颈内动脉及后循环的血流分布区.方法 使用伪连续动脉自旋标记成像方法 对7名健康志愿者和6例脑血管病患者的左、右颈内动脉及椎基底动脉编码进行头部横断而成像和图像后处理,得到来源于上述不同血管的脑血流量(CBF)的灌注分布图,计算7名志愿者的双侧大脑厌、白质及半脑的CBF.比较脑血管病患者的血流分布结果 与DSA图像的一致性及低灌注区域与液体衰减反转恢复(FLAIR)T2WI的高信号区域大小.结果 定量测量正常志愿者的半CBF为(32.6±4.3)ml·min-1·100 g-1,脑白质血流最(10.8±0.9)ml·min-1·100 g-1,脑灰质血流量(55.6±2.9)ml·min-1·100 g-1.脑血管病患者的脑血流分布异常、侧支循环血流分布与DSA对应良好;所有患者低灌注区域比FLAIR T2WI显示的高信号区域范围更大.结论 血管编码动脉自旋标记MR脑灌注成像可以无创地定性并定量不同血管来源的脑血供.%Objective To evaluate a noninvasive vessel encoded imaging for selective mapping of the flow territories of the left and right internal carotid arteries and vertebral-basilar arteries. Methods Seven volunteers [(33.5±4.1) years ; 3 men, 4 women] and 6 patients [(55.2 ± 3.2) years; 2 men,4women] were given written informed consent approved by the institutional review board before participating in the study. A pseudo-continuous tagging pulse train is modified to encode all vessels of interest. The selectivity of this method was demonstrated. Regional perfusion imaging was developed on the same arterial spin labeling sequence. Perfusion-weighted images of the selectively labeled cerebral arteries were obtained by subtraction of the labeled from control images. The CBF values of hemisphere, white matter, and gray matter of volunteers were calculated. The vessel territories on patients were compared with DSA. The low

  13. Using intravoxel incoherent motion MR imaging to study the renal pathophysiological process of contrast-induced acute kidney injury in rats: Comparison with conventional DWI and arterial spin labelling

    International Nuclear Information System (INIS)

    To investigate the potential of intravoxel incoherent motion (IVIM) to assess the renal pathophysiological process in contrast-induced acute kidney injury (CIAKI). Twenty-seven rats were induced with CIAKI model, six rats were imaged longitudinally at 24 h prior to and 30 min, 12, 24, 48, 72 and 96 h after administration; three rats were randomly chosen from the rest for serum creatinine and histological studies. D, f, D* and ADC were calculated from IVIM, and renal blood flow (RBF) was obtained from arterial spin labelling (ASL). A progressive reduction in D and ADC was observed in cortex (CO) by 3.07 and 8.62 % at 30 min, and by 25.77 and 28.16 % at 48 h, respectively. A similar change in outer medulla (OM) and inner medulla (IM) was observed at a later time point (12-72 h). D values were strongly correlated with ADC (r = 0.885). As perfusion measurement, a significant decrease was shown for f in 12-48 h and an increase in 72-96 h. A slightly different trend was found for D*, which was decreased by 26.02, 21.78 and 10.19 % in CO, OM and IM, respectively, at 30 min. f and D* were strongly correlated with RBF in the cortex (r = 0.768, r = 0.67), but not in the medulla. IVIM is an effective imaging tool for monitoring progress in renal pathophysiology undergoing CIAKI. (orig.)

  14. Glial fibrillary acidic protein (GFAP) immunoreactivity correlates with cortical perfusion parameters determined by bolus tracking arterial spin labelling (bt-ASL) magnetic resonance (MR) imaging in the Wistar Kyoto rat.

    Science.gov (United States)

    Gormley, Shane; Rouine, Jennifer; McIntosh, Allison; Kerskens, Christian; Harkin, Andrew

    2016-06-01

    Alterations in astrocyte number and function have been implicated in the pathophysiology of a number of psychiatric disorders. The development of magnetic resonance imaging (MRI) as a tool in the animal laboratory has enabled an investigation of the relationship between pathological and neuroimaging markers in animal models. However the physiological processes which underlie these markers and their role in mediating behavioural deficits is still poorly understood. Rodent models have provided us with important insights into physiological and cellular mechanisms which may mediate anxiety and depression-related behaviours. The Wistar-Kyoto (WKY) rat is a strain which endogenously expresses highly anxious and depressive-like behaviours and has previously been reported to exhibit alterations in immunoreactivity for the astrocytic marker glial fibrillary acidic protein (GFAP) in brain sub-regions relative to more stress resilient out-bred strains. Here we report that the depressive and anxiety-like behaviours exhibited by the WKY rat strain are associated with alterations in brain morphology including a decrease in hippocampal volume, coupled with reduced resting state frontal cortical perfusion as assessed by MR bolus tracking arterial spin labelling (bt-ASL) relative to the out-bred Wistar strain. Pre-limbic cortical GFAP immunoreactivity and astrocyte cell number were positively correlated with cortical blood perfusion in the WKY strain. These experiments provide a link between pathological and neuroimaging markers of aberrant astrocytic function and add validity to the WKY rat as a model for co-morbid anxiety and depression. PMID:27068181

  15. Using intravoxel incoherent motion MR imaging to study the renal pathophysiological process of contrast-induced acute kidney injury in rats: Comparison with conventional DWI and arterial spin labelling

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Long; Zhang, Bin [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Southern Medical University, Graduate College, Guangzhou (China); Chen, Wen-bo; Liang, Chang-hong; Zhang, Shui-xing [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Chan, Kannie W.Y.; Li, Yu-guo; Liu, Guan-shu [The Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of MR Research, Baltimore, MD (United States)

    2016-06-15

    To investigate the potential of intravoxel incoherent motion (IVIM) to assess the renal pathophysiological process in contrast-induced acute kidney injury (CIAKI). Twenty-seven rats were induced with CIAKI model, six rats were imaged longitudinally at 24 h prior to and 30 min, 12, 24, 48, 72 and 96 h after administration; three rats were randomly chosen from the rest for serum creatinine and histological studies. D, f, D* and ADC were calculated from IVIM, and renal blood flow (RBF) was obtained from arterial spin labelling (ASL). A progressive reduction in D and ADC was observed in cortex (CO) by 3.07 and 8.62 % at 30 min, and by 25.77 and 28.16 % at 48 h, respectively. A similar change in outer medulla (OM) and inner medulla (IM) was observed at a later time point (12-72 h). D values were strongly correlated with ADC (r = 0.885). As perfusion measurement, a significant decrease was shown for f in 12-48 h and an increase in 72-96 h. A slightly different trend was found for D*, which was decreased by 26.02, 21.78 and 10.19 % in CO, OM and IM, respectively, at 30 min. f and D* were strongly correlated with RBF in the cortex (r = 0.768, r = 0.67), but not in the medulla. IVIM is an effective imaging tool for monitoring progress in renal pathophysiology undergoing CIAKI. (orig.)

  16. Pseudocontact shifts from mobile spin labels

    CERN Document Server

    Suturina, E

    2016-01-01

    This paper presents a detailed analysis of the pseudocontact shift (PCS) field induced by a mobile spin label that is viewed as a probability density distribution with an associated magnetic susceptibility. It is demonstrated that anisotropy in this density can lead to significant deviations from the commonly used point dipole approximation for PCS. Analytical and numerical solutions are presented for the general partial differential equation that describes the non-point case. It is also demonstrated that it is possible to reconstruct paramagnetic centre probability distributions from experimental PCS data.

  17. Contrast optimization in multiphase arterial spin labeling

    International Nuclear Information System (INIS)

    Multiphase ASL is an effective way to overcome the regional variation of the transit time that difficult the estimation of perfusion values. However, with conventional multiple phases ASL techniques, the ASL contrast at later phases is impaired due to repeated application of excitation pulses and longitudinal relaxation making it difficult to evaluate the tissue perfusion in regions where the transit time is longer. In the present study, we show an improvement of the acquisition scheme by exploring a modulation on the flip angle of the MR acquisition to keep the ASL contrast constant over multiple phases. (author)

  18. 脉冲式及伪连续式动脉自旋标记技术静息态脑灌注对比研究%Comparative Study of Cerebral Perfusion by Using Pulsed and Pseudo Continuous Arterial Spin Labeling Techniques in Resting State

    Institute of Scientific and Technical Information of China (English)

    陈春晓; 郭超; 郑罡; 王利; 赵铁柱; 卢光明

    2013-01-01

    比较研究了脉冲式动脉自旋标记(pulsed arterial spin labeling,PASL)和伪连续式动脉自旋标记(pseudo continuous arterial spin labeling,pCASL)两种磁共振成像技术在静息态脑灌注中的应用.在静息态下,采用两种动脉自旋标记技术采集了10例健康志愿者的脑灌注数据,并计算脑血流量.两种技术的测量结果均显示,人脑默认网络中的楔前叶、角回、岛叶和后扣带回的相对脑血流量高于全脑平均灌注,而pCASL更敏感.在白质、额叶、顶叶、小脑和小脑蚓区域,pCASL和PASL测量得到的灌注值有显著性差异,除枕叶、小脑和小脑蚓外,PASL测量得到的灌注量小于pCASL.在全脑范围内,pCASL的信噪比明显高于PASL,且负灌注量很少.实验表明,pCASL可以提供比PASL更准确的测量结果.%The comparative study between pulsed arterial spin labeling (PASL) and pseudo continuous arterial spin labeling (pCASL) in resting cerebral perfusion were investigated. The PASL and pCASL data of 10 healthy subjects were acquired by a 3.0 T MR scanner during resting state, and the relative cerebral blood flows (rCBF) were then respectively quantified and analyzed. The results revealed that both techniques were able to detect the rCBF. CBFs in the precuneus, angular gyrus, insula, posterior cingulate cortex in default network were higher than the mean CBF in the whole brain, and pCASL was much more sensitive. Comparison with PASL sequence, CBFs obtained by the pCASL were significantly higher in white matter, frontal and parietal lobe, cerebellum and cerebellar vermis than that of PASL. Moreover, in the whole brain, higher SNR and less negative perfusion voxels were found in pCASL. The experimental results show that pCASL provides more accurate measurements than PASL in cerebral blood flow perfusion.

  19. Spin-probe spin-label studies of sodium dodecyl sulfate micelles

    International Nuclear Information System (INIS)

    The magnetic interactions of paramagnetic ions with nitroxide labels in micelles was determined by using spin-label, spin-probe technique. The results fro EPR spectrometer show that the line broadening is dominated by exchange interactions. This result points to a rapid averaging of dieletric environments. (Author)

  20. Intramembrane Polarity by Electron Spin Echo Spectroscopy of Labeled Lipids

    Science.gov (United States)

    Bartucci, Rosa; Guzzi, Rita; Marsh, Derek; Sportelli, Luigi

    2003-01-01

    The association of water (D2O) with phospholipid membranes was studied by using pulsed-electron spin resonance techniques. We measured the deuterium electron spin echo modulation of spin-labeled phospholipids by D2O in membranes of dipalmitoyl phosphatidylcholine with and without 50 mol% of cholesterol. The Fourier transform of the relaxation-corrected two-pulse echo decay curve reveals peaks, at one and two times the deuterium NMR frequency, that arise from the dipolar hyperfine interaction of the deuterium nucleus with the unpaired electron spin of the nitroxide-labeled lipid. For phosphatidylcholine spin-labeled at different positions down the sn-2 chain, the amplitude of the deuterium signal decreases toward the center of the membrane, and is reduced to zero from the C-12 atom position onward. At chain positions C-5 and C-7 closer to the phospholipid headgroups, the amplitude of the deuterium signal is greater in the presence of cholesterol than in its absence. These results are in good agreement with more indirect measurements of the transmembrane polarity profile that are based on the 14N-hyperfine splittings in the conventional continuous-wave electron spin resonance spectrum. PMID:12547783

  1. Technological advances in site-directed spin labeling of proteins

    OpenAIRE

    Hubbell, Wayne L.; López, Carlos J.; Altenbach, Christian; Yang, Zhongyu

    2013-01-01

    Molecular flexibility over a wide time range is of central importance to the function of many proteins, both soluble and membrane. Revealing the modes of flexibility, their amplitudes, and time scales under physiological conditions is the challenge for spectroscopic methods, one of which is site-directed spin labeling EPR (SDSL-EPR). Here we provide an overview of some recent technological advances in SDSL-EPR related to investigation of structure, structural heterogeneity, and dynamics of pr...

  2. 基于动脉自旋标记技术的内侧颞叶癫痫病人脑血流灌注成像研究%A Cerebral Blood Flow Perfusion Analysis in Patients with Temporal Lobe Epilepsy by Use of Arterial Spin Labeled Perfusion MR Imaging

    Institute of Scientific and Technical Information of China (English)

    郭超; 郑罡; 陈春晓; 沈连芳; 张志强; 王利; 卢光明

    2011-01-01

    Using arterial spin labeling (ASL), the authors have studied and analyzed the present of perfusion abnormalities in patients with mesial temporal lobe epilepsy (mTLE). 30 interictal patients with mTLE and hippocampal sclerosis (HS) including 16 patients with left mTLE (LTLE) and 14 patients with right mTLE (RTLE), and 22 healthy volunteers underwent pulsed ASL (PASL) in resting state. Relative cerebral blood flow (rCBF) was calculated and compared using group analysis of statistic parameters mapping and perfusion asymmetric index of region of interest. The results demonstrated that compared to controls, the rCBF of epileptics decreased in bilateral parahippocampal, fusiform, frontal lobe, temporal lobe and ipsilateral insula, and hippocampus in patients with LTLE, bilateral hippocampus, parahippocampal, fusiform, frontal lobe and temporal lobe, and ipsilateral amygdale and insula in patients with RTLE, but decreasing degree and area in ipsilateral side was much more than contralateral side. This study provided evidences that the HS may cause functional abnormalities in seizure zones and influence the whole brain through seizures in patients with mTLE.%基于动脉自旋标记(arterial spin labeling,ASL)技术,分析内侧颞叶癫痫(mesialtemporal lobe epilepsy,mTLE)患者大脑血流灌注(perfusion)的改变情况.在静息态下,采集了30例内侧颞叶癫痫伴单侧海马硬化发作间期患者(其中左侧16例,右侧14例)及22例健康志愿者的ASL数据,并通过计算获取其相对脑血流量(relative CBF,rCBF)及灌注不对称率(asymmetric index,AI).癫痫病人与正常人的比较结果表明:左侧mTLE患者在两侧海马旁回、梭状回、额叶、颞叶和患侧海马回及岛叶,右侧mTLE患者在两侧海马回、海马旁回、额叶、颞叶和患侧杏仁核及岛叶,rCBF均有所下降,且患侧的下降程度和范围均大于对侧.说明mTLE患者的海马硬化可能导致了痫灶区功能异常,并通过癫痫的发作影响到全脑.

  3. Nanoscale imaging of paramagnetic spin labels using a single spin in diamond

    Science.gov (United States)

    Ariyaratne, Amila; Myers, Bryan; Pelliccione, Matthew; Jayich, Ania

    Spin-labeling molecules with paramagnetic species is a powerful technique for probing molecular structure. However, current techniques are ensemble measurements, inherently lacking the sensitivity to detect a single spin or the conformational properties of a single biomolecule. In this talk, we demonstrate an imaging technique that has the promise of single-spin imaging and ultimately molecular structure imaging. We present two-dimensional nanoscale imaging of a monolayer of gadolinium (Gd) atomic spin labels at ambient conditions. The sensing element is a single nitrogen-vacancy (NV) center in diamond. A patterned monolayer of Gd atoms self-assembled on a Si atomic force microscopy tip is controllably interacted with and detected by the NV center. The fluctuating magnetic field generated by GHz-scale Gd spin flips relaxes the NV center in a manner that depends strongly on the Gd-NV separation. Using this technique, we demonstrate a Gd-induced reduction of the T1 relaxation time of the NV center with nm spatial resolution. Our results indicate that nanometer-scale imaging of individual electronic spins at ambient conditions is within reach. This will ultimately enable the study of structural and functional studies of single biomolecules in their native, folded state.

  4. Peptide-membrane Interactions by Spin-labeling EPR

    Science.gov (United States)

    Smirnova, Tatyana I.; Smirnov, Alex I.

    2016-01-01

    Site-directed spin labeling (SDSL) in combination with Electron Paramagnetic Resonance (EPR) spectroscopy is a well-established method that has recently grown in popularity as an experimental technique, with multiple applications in protein and peptide science. The growth is driven by development of labeling strategies, as well as by considerable technical advances in the field, that are paralleled by an increased availability of EPR instrumentation. While the method requires an introduction of a paramagnetic probe at a well-defined position in a peptide sequence, it has been shown to be minimally destructive to the peptide structure and energetics of the peptide-membrane interactions. In this chapter, we describe basic approaches for using SDSL EPR spectroscopy to study interactions between small peptides and biological membranes or membrane mimetic systems. We focus on experimental approaches to quantify peptide-membrane binding, topology of bound peptides, and characterize peptide aggregation. Sample preparation protocols including spin-labeling methods and preparation of membrane mimetic systems are also described. PMID:26477253

  5. Larmor labeling of neutron spin using superconducting Wollaston prisms

    Science.gov (United States)

    Li, Fankang

    Neutron spin Larmor labeling using magnetic Wollaston prisms (WP) provides a way to overcome some of the limitations arising from the nature of neutron beams: low flux and divergence. Using superconducting films and tapes, a series of strong, well-defined shaped magnetic fields can be produced due to both the zero-resistance and Meissner effect in superconductors. Using finite element simulations, the criterion to build a superconducting magnetic Wollaston prism with high encoding efficiency and low Larmor phase aberrations are presented. To achieve a high magnetic field and simplify the maintenance, we optimize the design using careful thermal analysis. The measured neutron spin flipping efficiency is measured to be independent of both the neutron wavelength and energizing current, which is a significant improvement over other devices with similar functions. A highly linear variation of the Larmor phase is measured across the device, which ensures a highly uniform encoding of scattering angles into the neutron spin Larmor phase. Using two WPs, the correlation function for a colloidal silica sample was measured by spin echo modulated small angle neutron scattering (SEMSANS) and agrees well with other techniques. Using Monte Carlo code (McStas), we further investigated the SEMSANS setup and showed the requirements to improve its performance. We have proposed a new technique to implement neutron spin echo on a triple axis neutron spectrometer to achieve high resolution measurements of the lifetime of dispersive phonon excitations. The spin echo is tuned by appropriate choice of magnetic fields instead of physically tilting the coils used in traditional methods. This new approach allows a higher energy resolution and a larger effective tilting angle and hence larger group velocity to be measured.

  6. RosettaEPR: rotamer library for spin label structure and dynamics.

    Directory of Open Access Journals (Sweden)

    Nathan S Alexander

    Full Text Available An increasingly used parameter in structural biology is the measurement of distances between spin labels bound to a protein. One limitation to these measurements is the unknown position of the spin label relative to the protein backbone. To overcome this drawback, we introduce a rotamer library of the methanethiosulfonate spin label (MTSSL into the protein modeling program Rosetta. Spin label rotamers were derived from conformations observed in crystal structures of spin labeled T4 lysozyme and previously published molecular dynamics simulations. Rosetta's ability to accurately recover spin label conformations and EPR measured distance distributions was evaluated against 19 experimentally determined MTSSL labeled structures of T4 lysozyme and the membrane protein LeuT and 73 distance distributions from T4 lysozyme and the membrane protein MsbA. For a site in the core of T4 lysozyme, the correct spin label conformation (Χ1 and Χ2 is recovered in 99.8% of trials. In surface positions 53% of the trajectories agree with crystallized conformations in Χ1 and Χ2. This level of recovery is on par with Rosetta performance for the 20 natural amino acids. In addition, Rosetta predicts the distance between two spin labels with a mean error of 4.4 Å. The width of the experimental distance distribution, which reflects the flexibility of the two spin labels, is predicted with a mean error of 1.3 Å. RosettaEPR makes full-atom spin label modeling available to a wide scientific community in conjunction with the powerful suite of modeling methods within Rosetta.

  7. Detection of atomic spin labels in a lipid bi-layer using a single-spin nanodiamond probe

    CERN Document Server

    Kaufmann, Stefan; Hall, Liam T; Perunicic, Viktor; Senn, Philipp; Steinert, Steffen; McGuinness, Liam P; Johnson, Brett C; Ohshima, Takeshi; Caruso, Frank; Wrachtrup, Joerg; Scholten, Robert E; Mulvaney, Paul; Hollenberg, Lloyd C L

    2013-01-01

    Magnetic field fluctuations arising from fundamental spins are ubiquitous in nanoscale biology, and are a rich source of information about the processes that generate them. However, the ability to detect the few spins involved without averaging over large ensembles has remained elusive. Here we demonstrate the detection of gadolinium spin labels in an artificial cell membrane under ambient conditions using a single-spin nanodiamond sensor. Changes in the spin relaxation time of the sensor located in the lipid bilayer were optically detected and found to be sensitive to near-individual proximal gadolinium atomic labels. The detection of such small numbers of spins in a model biological setting, with projected detection times of one second, opens a new pathway for in-situ nanoscale detection of dynamical processes in biology.

  8. Spin Labeling ESR Investigation of Covalently Bound Residues in Soil

    Science.gov (United States)

    Aleksandrova, Olga; Steinhoff, Heinz-Juergen; Klasmeier, Joerg; Schulz, Marcus; Matthies, Michael

    2013-04-01

    Organic xenobiotic chemicals, such as pesticides, biocides and veterinary pharmaceuticals, interact with soil, which results in the simultaneous formations of metabolites, mineralization products, and bound or non-extractable residues (NER). Substances or metabolites with reactive functional groups, such as aniline or phenol, have a tendency to give a larger proportion of NER. Despite numerous studies on NER, the majority of their chemical structures is still unknown. Reversible sequestration and irreversible formation of NER were also observed for veterinary antibiotic pharmaceuticals, after their application to soil with and without manure. For this purpose, we hypothesized a key role of specific functional groups of soil contaminants, via which contaminants are covalently bound to soil constituents, and advance a method of spin labeling ESR investigation of reaction products using a membrane method. Spin labels (SL) represent chemically stable paramagnetic molecules used as molecular labels and molecular probes for testing the covalent binding, structural properties, and molecular mobility of different physical, chemical, and biological systems. In the case of covalent binding of SL, their ESR spectra become broadened. We used stable nitroxide radicals (NR) as SL. These radicals modeled organic chemical contaminants and differed only in one functional group. The paramagnetic SL 4-Amino Tempo (4-amino-2,2,6,6-tetramethyl-1-piperidinylox) differed from Tempo (2,2,6,6-Tetramethylpiperidinooxy) in a substituent at the para-position of the piperidine ring, whereas Aniline Tempo (1-Piperidinyloxy, 2,2,6,-tetramethyl, 6-Aniline) differed from Tempo in an Aniline substituting one CH3 functional group. Before experimental analysis, we tested temporal changes in the concentration of both NR incubated with soil and found that the life-times of them in soil exceeded 3 days. We contaminated and labeled soil samples with NR, adding to soil the aqueous solution, which already

  9. Distance determination between low-spin ferric haem and nitroxide spin label using DEER: the neuroglobin case

    Science.gov (United States)

    Ezhevskaya, M.; Bordignon, E.; Polyhach, Y.; Moens, L.; Dewilde, S.; Jeschke, G.; Van Doorslaer, S.

    2013-10-01

    This work demonstrates for the first time the feasibility of using double electron-electron resonance (DEER) to determine the inter-spin distance between nitroxide spin labels and low-spin (S = 1/2) ferric haem centres. For these means, two human neuroglobin variants were spin labelled leading to singly labelled haem proteins with the nitroxide label on one of the natural Cys residues (Cys55 or Cys120). Room-temperature electron paramagnetic resonance was used to characterise the mobility of the nitroxide labels and X- and Q-band DEER experiments were performed to detect nitroxide-haem distances. Effects of residual nuclear modulations in the DEER traces were carefully evaluated. The DEER-derived distances were compared with theoretical predictions from an X-ray diffraction structure of human neuroglobin using a rotamer library approach as well as with distance information obtained from electron relaxation measurements. The structural biological implications of the spin-labelled side chains' dynamics and of the obtained distances are also discussed.

  10. Parametrization, molecular dynamics simulation and calculation of electron spin resonance spectra of a nitroxide spin label on a poly-alanine alpha helix

    OpenAIRE

    Sezer, Deniz; Freed, Jack H.; Roux, Benoît

    2008-01-01

    The nitroxide spin label 1-oxyl-2,2,5,5-tetramethylpyrroline-3-methyl-methanethiosulfonate (MTSSL), commonly used in site-directed spin labeling of proteins, is studied with molecular dynamics (MD) simulations. After developing force field parameters for the nitroxide moiety and the spin label linker, we simulate MTSSL attached to a poly-alanine alpha helix in explicit solvent to elucidate the factors affecting its conformational dynamics. Electron spin resonance spectra at 9 and 250 GHz are ...

  11. Effect of ADP on the orientation of spin-labeled myosin heads in muscle fibers: A high-resolution study with deuterated spin labels

    International Nuclear Information System (INIS)

    We have used electron paramagnetic resonance (EPR) to determine the effects of ADP on the orientational distribution of nitroxide spin labels attached to myosin heads in skinned rabbit psoas muscle fibers. To maximize the specificity of labeling, we spin-labeled isolated myosin heads (subfragment 1) on a single reactive thiol (SH1) and diffused them into unlabeled muscle fibers. To maximize spectral and orientational resolution, we used perdeuterated spin labels, 2H-MSL and 2H-IASL, eliminating superhyperfine broadening and thus narrowing the line widths. Two different spin labels were used, with different orientation relative to the myosin head, to ensure that the results are not affected by unfavorable probe orientation. In rigor, a very narrow three-line spectrum was observed for both spin labels, indicating a narrow orientational distribution, as reported previously. ADP induced very slight changes in the spectrum, corresponding to very slight (but significant) changes in the orientational distribution. These changes were quantified by a digital analysis of the spectra, using a two-step simplex fitting procedure. First, the magnetic tensor values and line widths were determined by fitting the spectrum of a randomly oriented sample. Then the spectrum of oriented fibers was fit to a model by assuming a Gaussian distribution of the tilt angle (theta) and twist angle (phi) of the nitroxide principal axes relative to the fiber axis. A single-Gaussian distribution resulted in inadequate fits, but a two-component model gave excellent results. ADP induces a small (less than 5 degrees) rotation of the major components for both spin labels, along with a similarly small increase of disorder about the average positions

  12. Stearic acid spin labels in lipid bilayers: insight through atomistic simulations.

    Science.gov (United States)

    Stimson, Lorna; Dong, Lei; Karttunen, Mikko; Wisniewska, Anna; Dutka, Małgorzata; Róg, Tomasz

    2007-11-01

    Spin-labeled stearic acid species are commonly used for electron paramagnetic resonance (EPR) studies of cell membranes to investigate phase transitions, fluidity, and other physical properties. In this paper, we use large-scale molecular dynamics simulations to investigate the position and behavior of nitroxide spin labels attached to stearic acid molecules in dipalmitoylphosphatidylcholine (DPPC) bilayers. The results of these studies are potentially very important for the interpretation of EPR spectra, which rely on assumptions about the position of the label in the membrane. Additionally, we investigate the effect of chirality and ionization of the carboxyl group of the label. For a non-ionized species, we observe that spin-label molecules are even able to make flip-flop transitions between the leaflets of the bilayer. Such transitions have been previously observed only in very rare cases in molecular simulations. PMID:17929861

  13. Detection of renal arteries with fast spin-echo magnetic resonance imaging

    International Nuclear Information System (INIS)

    With the increasing use of non-invasive imaging with MR and volumetric CT to evaluate renal arteries, the ability to accurately detect the number and state of native renal arteries becomes critical if conventional angiography is to be supplanted in these settings. The present study evaluated the utility of a fast spin-echo (FSE) T2-weighted sequence to detect the number and course of renal arteries and their ostia compared to conventional angiography. Ten patients underwent conventional catheter angiography either for renal artery stenosis evaluation or as potential renal donors. Each patient then had an MR study of the renal arteries and kidneys with FSE MR (TR = 4000 ms, TE = 102 ms, eight- echo train length, 5-mm-thick interleaved 128 phase encodes, superior and inferior saturation pulses, number of excitations (NEX) = 4, on a 1.5-T superconducting magnet. Images were reviewed by two 'blinded' radiologists and renal arteries were counted and their ostia were evaluated. Results were compared with angiography and inter- and intra-observer statistics were calculated. All 10 patients underwent MR successfully, nine for renal artery stenosis (RAS) evaluation and one was a renal donor. A total of 24 renal arteries were imaged in 19 kidneys. Fast spin-echo MR is 95% accurate (95%CI: 88-100%) in detection of renal arteries, with no statistical difference between FSE MR and catheter angiography (McNemar P = 0.0). Inter- and intra-observer statistics demonstrate good-to-excellent agreement in renal artery detection (kappa: 0.63-0.90). In one case of RAS evaluation an incidental adrenal mass was detected as the aetiology of the patient's hypertension. Fast spin-echo MR can be a useful adjunct as part of the imaging for renal arteries with MRI. Copyright (1998) Blackwell Science Pty Ltd

  14. Conformational dynamics of nucleic acid molecules studied by PELDOR spectroscopy with rigid spin labels

    Science.gov (United States)

    Prisner, T. F.; Marko, A.; Sigurdsson, S. Th.

    2015-03-01

    Nucleic acid molecules can adopt a variety of structures and exhibit a large degree of conformational flexibility to fulfill their various functions in cells. Here we describe the use of Pulsed Electron-Electron Double Resonance (PELDOR or DEER) to investigate nucleic acid molecules where two cytosine analogs have been incorporated as spin probes. Because these new types of spin labels are rigid and incorporated into double stranded DNA and RNA molecules, there is no additional flexibility of the spin label itself present. Therefore the magnetic dipole-dipole interaction between both spin labels encodes for the distance as well as for the mutual orientation between the spin labels. All of this information can be extracted by multi-frequency/multi-field PELDOR experiments, which gives very precise and valuable information about the structure and conformational flexibility of the nucleic acid molecules. We describe in detail our procedure to obtain the conformational ensembles and show the accuracy and limitations with test examples and application to double-stranded DNA.

  15. Characterizing Active Pharmaceutical Ingredient Binding to Human Serum Albumin by Spin-Labeling and EPR Spectroscopy.

    Science.gov (United States)

    Hauenschild, Till; Reichenwallner, Jörg; Enkelmann, Volker; Hinderberger, Dariush

    2016-08-26

    Drug binding to human serum albumin (HSA) has been characterized by a spin-labeling and continuous-wave (CW) EPR spectroscopic approach. Specifically, the contribution of functional groups (FGs) in a compound on its albumin-binding capabilities is quantitatively described. Molecules from different drug classes are labeled with EPR-active nitroxide radicals (spin-labeled pharmaceuticals (SLPs)) and in a screening approach CW-EPR spectroscopy is used to investigate HSA binding under physiological conditions and at varying ratios of SLP to protein. Spectral simulations of the CW-EPR spectra allow extraction of association constants (KA ) and the maximum number (n) of binding sites per protein. By comparison of data from 23 SLPs, the mechanisms of drug-protein association and the impact of chemical modifications at individual positions on drug uptake can be rationalized. Furthermore, new drug modifications with predictable protein binding tendency may be envisaged. PMID:27460503

  16. Electron spin resonance of copper labelled myoglobin crystals

    International Nuclear Information System (INIS)

    Single crystals of sperm whale met mioglobin were doped with Cu2+ by immersion in a satured solution of NH3(SO4) containing diluted Cu(SO4). Angular variations of the EPR espectra were measured in the planes: ab, ac* and bc* (c* is an axis perpendicular to the ab plane of the monoclinic crystal). A fitting using a spin Hamiltonian with axial symmetry calculated up to second order gives the EPR hyperfine constants g = (2.328+-0.002), g = (2.069+-0.002), A = (162+-3) gauss and A = (20+-3) gauss. The parallel axis makes an angle of (390 +- 20) with the crystaline b axis. A super hyperfine spectra was evidenciated in a perpendicular direction associated with gxx or gyy. This splitting may be attributed to a spread of a wavefunction of the unpaired electron over one nitrogene of the imidazole ring of the Histidine A10 in Mb: Cu2+

  17. Oxidative stress-mediated protein conformation changes: ESR study of spin-labelled staphylococcal nuclease

    International Nuclear Information System (INIS)

    We report on the electron spin resonance (ESR) study of the photo-oxidative stress-mediated protein conformation changes in the spin-labelled protein staphylococcal nuclease (SNase). The photo-oxidative stress was brought on by photosensitization of singlet oxygen (1Δg) in the presence of a novel photosensitizer, water-soluble fullerol C60(OH)19(ONa)17, and resulted in partial protein denaturation. This process was monitored via ESR measurements performed for a spin-labelled SNase Thr-62-Cys mutant, with MTSSL spin label (SL) attached to the cysteine 62 residue (SNase T62C-SL). Prior to ESR measurements of the oxidative stress-induced alterations in protein conformations, the efficiency of C60(OH)19(ONa)17 for 1Δg-generation was confirmed by three different techniques: (i) selective reactive scavenging of 1Δg and ESR detection of the resulting paramagnetic product (ii) 1Δg-mediated photo-oxidative loss of tryptophan and (iii) by measuring the characteristic near-infrared phosphorescence of singlet oxygen at 1270 nm. The observed evolution of the ESR spectra of SNase T62C-SL as a function of exposure to the photo-oxidative stress points to marked changes in protein conformation due to the deleterious action of 1Δg

  18. Arterial spin labelling reveals prolonged arterial arrival time in idiopathic Parkinson's disease

    Directory of Open Access Journals (Sweden)

    Sarah Al-Bachari

    2014-01-01

    A significant (p = 0.005 increase in whole brain averaged baseline AAT was observed in IPD participants (mean ± SD age 1532 ± 138 ms compared to controls (mean ± SD age 1335 ± 165 ms. Voxel-wise analysis revealed this to be widespread across the brain. However, there were no statistically significant differences in white matter lesion score, CBF, or CVR between patients and controls. Regional CBF, but not AAT, in the IPD group was found to correlate positively with Montreal cognitive assessment (MoCA scores. These findings provide further evidence of alterations in NVS in IPD.

  19. Dynamic nuclear polarization of membrane proteins: covalently bound spin-labels at protein–protein interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Wylie, Benjamin J. [Columbia University, Department of Chemistry (United States); Dzikovski, Boris G. [Cornell University, National Biomedical Center for Advanced ESR Technology, Department of Chemistry and Chemical Biology (United States); Pawsey, Shane; Caporini, Marc; Rosay, Melanie [Bruker BioSpin Corporation (United States); Freed, Jack H. [Cornell University, National Biomedical Center for Advanced ESR Technology, Department of Chemistry and Chemical Biology (United States); McDermott, Ann E., E-mail: aem5@columbia.edu [Columbia University, Department of Chemistry (United States)

    2015-04-15

    We demonstrate that dynamic nuclear polarization of membrane proteins in lipid bilayers may be achieved using a novel polarizing agent: pairs of spin labels covalently bound to a protein of interest interacting at an intermolecular interaction surface. For gramicidin A, nitroxide tags attached to the N-terminal intermolecular interface region become proximal only when bimolecular channels forms in the membrane. We obtained signal enhancements of sixfold for the dimeric protein. The enhancement effect was comparable to that of a doubly tagged sample of gramicidin C, with intramolecular spin pairs. This approach could be a powerful and selective means for signal enhancement in membrane proteins, and for recognizing intermolecular interfaces.

  20. Dynamic nuclear polarization of membrane proteins: covalently bound spin-labels at protein–protein interfaces

    International Nuclear Information System (INIS)

    We demonstrate that dynamic nuclear polarization of membrane proteins in lipid bilayers may be achieved using a novel polarizing agent: pairs of spin labels covalently bound to a protein of interest interacting at an intermolecular interaction surface. For gramicidin A, nitroxide tags attached to the N-terminal intermolecular interface region become proximal only when bimolecular channels forms in the membrane. We obtained signal enhancements of sixfold for the dimeric protein. The enhancement effect was comparable to that of a doubly tagged sample of gramicidin C, with intramolecular spin pairs. This approach could be a powerful and selective means for signal enhancement in membrane proteins, and for recognizing intermolecular interfaces

  1. Investigation of surface potential asymmetry in phospholipid vesicles by a spin label relaxation method.

    OpenAIRE

    Sundberg, S A; Hubbell, W L

    1986-01-01

    In earlier work, Castle and Hubbell (1976) demonstrated the use of a spin-labeled amphiphile as a probe for the electrostatic potential at the outer surface of charged phospholipid vesicles. In recent experiments, we have shown that the hydrophobic anion tetraphenylboron (TPB) promotes transbilayer migration of the probe molecule. Relaxation data recorded following the rapid mixing of the probe with TPB-containing vesicle samples provides information about the electrostatic potentials at both...

  2. Site directed spin labelling and pulsed dipolar electron paramagnetic resonance (double electron-electron resonance) of force activation in muscle

    International Nuclear Information System (INIS)

    The recent development of site specific spin labelling and advances in pulsed electron paramagnetic resonance(EPR) have established spin labelling as a viable structural biology technique. Specific protein sites or whole domains can be selectively targeted for spin labelling by cysteine mutagenesis. The secondary structure of the proteins is determined from the trends in EPR signals of labels attached to consecutive residues. Solvent accessibility or label mobility display periodicities along the labelled polypeptide chain that are characteristic of β-strands (periodicity of 2 residues) or α-helices (3.6 residues). Low-resolution 3D structure of proteins is determined from the distance restraints. Two spin labels placed within 60-70 A of each other create a local dipolar field experienced by the other spin labels. The strength of this field is related to the interspin distance, ∝ r-3. The dipolar field can be measured by the broadening of the EPR lines for the short distances (8-20 A) or for the longer distances (17-70 A) by the pulsed EPR methods, double electron-electron resonance(DEER) and double quantum coherence (DQC). A brief review of the methodology and its applications to the multisubunit muscle protein troponin is presented below

  3. Technetium-99m labelled macroaggregated albumin arterial catheter perfusion scintigraphy: prediction of gastrointestinal toxicity in hepatic arterial chemotherapy.

    Science.gov (United States)

    Pelosi, E; Masaneo, I; Clara, R; Valetto, M R; Bellò, M; Zanon, C; Chiappino, I; Grosso, M; Mussa, A; Bisi, G

    2000-06-01

    Gastrointestinal toxicity from hepatic arterial infusion (HAI) of floxuridine in patients with liver metastases is probably due to extrahepatic perfusion or to partial escape of the drug from first-pass liver extraction. The aim of this study was to verify the role of technetium-99m-labelled macroaggregated albumin (99mTc-MAA) arterial catheter perfusion scintigraphy at the beginning of each chemotherapy cycle in decreasing or preventing gastrointestinal toxicity. We studied 167 consecutive patients. On the basis of the scintigraphic follow-up and the presence or absence of an intrahepatic arteriovenous shunt (IHAVS), we classified our patients into the following groups: (1) FU+ hepatic distribution pattern (DP), comprising 29 patients with regular scintigraphic follow-up who showed the expected distribution pattern at each control or a distribution pattern with transient alterations (extrahepatic escape) promptly reversed by the replacement of the catheter. Among these 29 patients there was one case of gastrointestinal toxicity. (2) FU- hepatic DP, comprising 128 patients who were evaluated with 99mTc-MAA only at the beginning of the first chemotherapy cycle, showed the expected distribution pattern and underwent HAI with no further scintigraphic evaluation. Among these 128 patients there were 28 cases of gastrointestinal toxicity. (3) FU+ pulmonary DP, comprising three patients with abnormally elevated pulmonary uptake (higher than 5%) and with regular scintigraphic follow-up. There were two cases of gastrointestinal toxicity among these three patients. (4) FU- pulmonary DP, comprising seven patients with abnormally elevated pulmonary uptake and without regular scintigraphic follow-up. There were four cases of gastrointestinal toxicity among these seven patients. The incidence of toxicity was significantly higher in group FU- hepatic DP than in group FU+ hepatic DP (21.9% vs 3.4%, Pscintigraphic follow-up is useful since it is able to promptly diagnose the

  4. Detection of intra-cardiac and intra-arterial thrombi using labelled platelets

    International Nuclear Information System (INIS)

    Scintigraphy with 111 Indium labelled platelets is a powerful tool to detect platelet deposits in vessels. This quantitative and functional imaging method needs a labeling procedure which completely preserves the properties of the platelets and allows the concept of hematologically active clot. Three main groups of patients were examined. 1-91 hematologically active intra-cardiac thrombi were detected. The follow-up of 19 of them shows 5 deaths and 7 cerebral embolisms. 2-372 patients with lower limb ischemia, mainly in the case of blue toe syndrome were examined. 158 times a comparison with the surgical patterns was possible, there were 3 false positive and 9 false negative results. 3-In a group of 310 patients with transient cerebro-vascular accidents, 38 times the records were poorly significant. In 27 patients we were able to compare the morphological examinations (including platelet scintigraphy) to the anatomical findings. Sensitivity was only 64% and specificity 71%. As in the cases of intra-cardiac thrombi, the method allows the follow-up of pharmacological therapy. Platelets labelled with 111 Indium provide the means for sensitive and specific detection of hematologically active clots in cardiac and arterial pathology

  5. Selectively dispersed isotope labeling for protein structure determination by magic angle spinning NMR

    Energy Technology Data Exchange (ETDEWEB)

    Eddy, Matthew T. [Massachusetts Institute of Technology, Department of Chemistry (United States); Belenky, Marina [Brandeis University, Department of Chemistry (United States); Sivertsen, Astrid C. [Massachusetts Institute of Technology, Francis Bitter Magnet Laboratory (United States); Griffin, Robert G. [Massachusetts Institute of Technology, Department of Chemistry (United States); Herzfeld, Judith, E-mail: herzfeld@brandeis.edu [Brandeis University, Department of Chemistry (United States)

    2013-10-15

    The power of nuclear magnetic resonance spectroscopy derives from its site-specific access to chemical, structural and dynamic information. However, the corresponding multiplicity of interactions can be difficult to tease apart. Complimentary approaches involve spectral editing on the one hand and selective isotope substitution on the other. Here we present a new 'redox' approach to the latter: acetate is chosen as the sole carbon source for the extreme oxidation numbers of its two carbons. Consistent with conventional anabolic pathways for the amino acids, [1-{sup 13}C] acetate does not label {alpha} carbons, labels other aliphatic carbons and the aromatic carbons very selectively, and labels the carboxyl carbons heavily. The benefits of this labeling scheme are exemplified by magic angle spinning spectra of microcrystalline immunoglobulin binding protein G (GB1): the elimination of most J-couplings and one- and two-bond dipolar couplings provides narrow signals and long-range, intra- and inter-residue, recoupling essential for distance constraints. Inverse redox labeling, from [2-{sup 13}C] acetate, is also expected to be useful: although it retains one-bond couplings in the sidechains, the removal of CA-CO coupling in the backbone should improve the resolution of NCACX spectra.

  6. Technetium-99m labelled macroaggregated albumin arterial catheter perfusion scintigraphy: prediction of gastrointestinal toxicity in hepatic arterial chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Pelosi, E.; Masaneo, I.; Valetto, M.R.; Bello, M.; Bisi, G. [Department of Nuclear Medicine, University of Turin, Turin (Italy); Clara, R.; Zanon, C.; Chiappino, I.; Mussa, A. [Division of Esophageal and Oncological Surgery, University of Turin, Turin (Italy); Grosso, M. [Division of Radiology, S. Croce e Carle Hospital, Cuneo (Italy)

    2000-06-01

    Gastrointestinal toxicity from hepatic arterial infusion (HAI) of floxuridine in patients with liver metastases is probably due to extrahepatic perfusion or to partial escape of the drug from first-pass liver extraction. The aim of this study was to verify the role of technetium-99m-labelled macroaggregated albumin ({sup 99m}Tc-MAA) arterial catheter perfusion scintigraphy at the beginning of each chemotherapy cycle in decreasing or preventing gastrointestinal toxicity. We studied 167 consecutive patients. On the basis of the scintigraphic follow-up and the presence or absence of an intrahepatic arteriovenous shunt (IHAVS), we classified our patients into the following groups: (1) FU+ hepatic distribution pattern (DP), comprising 29 patients with regular scintigraphic follow-up who showed the expected distribution pattern at each control or a distribution pattern with transient alterations (extrahepatic escape) promptly reversed by the replacement of the catheter. Among these 29 patients there was one case of gastrointestinal toxicity. (2) FU- hepatic DP, comprising 128 patients who were evaluated with {sup 99m}Tc-MAA only at the beginning of the first chemotherapy cycle, showed the expected distribution pattern and underwent HAI with no further scintigraphic evaluation. Among these 128 patients there were 28 cases of gastrointestinal toxicity. (3) FU+ pulmonary DP, comprising three patients with abnormally elevated pulmonary uptake (higher than 5%) and with regular scintigraphic follow-up. There were two cases of gastrointestinal toxicity among these three patients. (4) FU- pulmonary DP, comprising seven patients with abnormally elevated pulmonary uptake and without regular scintigraphic follow-up. There were four cases of gastrointestinal toxicity among these seven patients. The incidence of toxicity was significantly higher in group FU- hepatic DP than in group FU+ hepatic DP (21.9% vs 3.4%, P<0.05). In both the FU+ pulmonary DP and FU- pulmonary DP groups, the

  7. Survival in patients with hepatocellular carcinoma treated with intra-arterial {sup 131}I labelled lipiodol.

    Energy Technology Data Exchange (ETDEWEB)

    Butler, S.P.; Morris, D.L.; Ring, M.T.; King, J.; Parks, S.L.; Glenn, D.W. [St George Hospital, Kogarah, NSW, (Australia). Department of Nuclear Medicine

    1997-09-01

    Full text: The prognosis of untreated hepatocellular carcinoma (HCC) is dismal with a median survival of less than two months having been reported. {sup 131}l labelled Lipiodol as a treatment for hepatocellular carcinoma (HCC) has been shown to be as efficacious as intraarterial chemotherapy but with less toxicity than chemotherapy. 23 patients (19 men and four women, mean age 69 years, range 28 to 80 years) with unresectable Okuda Stage I (n = 23) or 11 (n = 2) HCC were treated over a three-year period. All patients had biopsy proved HCC and had not received any prior therapy. Before therapy, all patients underwent CT scans of abdomen and thorax and scintigraphic bone scans to exclude extrahepatic disease. Further, CT scanning of the liver was performed following the hepatic artery injection of unlabelled Lipiodol to ensure that the HCC was Lipiodol avid. 1 GBq of {sup 131}l labelled Lipiodol was injected into the hepatic artery followed by CT liver scanning at day 1 and day 60 to calculate tumour response. Whole body scintigraphic scanning was performed on days 1 and 21 for dosimetry calculations. Ten patients had a second dose of {sup 131}l Lipiodol due either increasing serum alpha feto-protein levels and/or tumour progression on CT scanning. Minimal toxicity was seen with this dose regime. Survival time was estimated from the time of treatment by the Kaplan-Meier method. For Okuda I, the median survival length was 12 months with actuarial survival rates of 91 per cent, 65 per cent, 59 per cent and 20 per cent at 3,6,9,12 and 24 months respectively. All Okuda II patients died within five months. Iodine-131 Lipiodol therapy is well tolerated and may prolong survival in certain HCC patients.

  8. Characterisation and vapour sensing properties of spin coated thin films of anthracene labelled PMMA polymer

    International Nuclear Information System (INIS)

    In the present article thin films of poly (methyl methacrylate) (PMMA) polymer labelled with anthracene (Ant-PMMA) prepared by spin coating are characterised by UV-visible spectroscopy, surface plasmon resonance (SPR), spectroscopic ellipsometry (SE) and Atomic Force Microscopy (AFM) and their organic vapour sensing properties are investigated. Ant-PMMA films' thickness are determined by performing theoretical fitting to experimental data measured using SPR and SE. Results obtained show that the spin-cast films are of good uniformity with an average thickness of 6-8 nm. Organic vapour sensing properties are studied using SPR technique during exposures to different volatile organic compounds (VOCs). Ant-PMMA films' response to the selected VOCs has been examined in terms of solubility parameters and molar volumes of the solvents, and the films were found to be largely sensitive to benzene vapour compared to other studied analytes.

  9. Backbone Dynamics of Alamethicin Bound to Lipid Membranes: Spin-Echo Electron Paramagnetic Resonance of TOAC-Spin Labels

    Science.gov (United States)

    Bartucci, Rosa; Guzzi, Rita; De Zotti, Marta; Toniolo, Claudio; Sportelli, Luigi; Marsh, Derek

    2008-01-01

    Alamethicin F50/5 is a hydrophobic peptide that is devoid of charged residues and that induces voltage-dependent ion channels in lipid membranes. The peptide backbone is likely to be involved in the ion conduction pathway. Electron spin-echo spectroscopy of alamethicin F50/5 analogs in which a selected Aib residue (at position n = 1, 8, or 16) is replaced by the TOAC amino-acid spin label was used to study torsional dynamics of the peptide backbone in association with phosphatidylcholine bilayer membranes. Rapid librational motions of limited angular amplitude were observed at each of the three TOAC sites by recording echo-detected spectra as a function of echo delay time, 2τ. Simulation of the time-resolved spectra, combined with conventional EPR measurements of the librational amplitude, shows that torsional fluctuations of the peptide backbone take place on the subnanosecond to nanosecond timescale, with little temperature dependence. Associated fluctuations in polar fields from the peptide could facilitate ion permeation. PMID:18096632

  10. Producing Radical-Free Hyperpolarized Perfusion Agents for In Vivo Magnetic Resonance Using Spin-Labeled Thermoresponsive Hydrogel.

    Science.gov (United States)

    Cheng, Tian; Mishkovsky, Mor; Junk, Matthias J N; Münnemann, Kerstin; Comment, Arnaud

    2016-07-01

    Dissolution dynamic nuclear polarization (DNP) provides a way to tremendously improve the sensitivity of nuclear magnetic resonance experiments. Once the spins are hyperpolarized by dissolution DNP, the radicals used as polarizing agents become undesirable since their presence is an additional source of nuclear spin relaxation and their toxicity might be an issue. This study demonstrates the feasibility of preparing a hyperpolarized [1-(13) C]2-methylpropan-2-ol (tert-butanol) solution free of persistent radicals by using spin-labeled thermoresponsive hydrophilic polymer networks as polarizing agents. The hyperpolarized (13) C signal can be detected for up to 5 min before the spins fully relax to their thermal equilibrium. This approach extends the applicability of spin-labeled thermoresponsive hydrogel to the dissolution DNP field and highlights its potential as polarizing agent for preparing neat slowly relaxing contrast agents. The hydrogels are especially suited to hyperpolarize deuterated alcohols which can be used for in vivo perfusion imaging. PMID:27184565

  11. Spin Labeling ESR Investigation of a Role of Humic Acids at Covalent Binding of Xenobiotics to Soil

    Science.gov (United States)

    Aleksandrova, Olga

    2014-05-01

    The environmental risk of organic xenobiotic chemicals released into soils is controlled by their sorption and binding processes. However, the molecular mechanisms of reversible and irreversible interactions of xenobiotics with soil constituents and an influence of humic substances on this interaction are only partly understood. New methods and approaches aimed at understanding of molecular mechanisms in the soil environment and a role of humic substances in the sorption and binding processes are today required to manage and keep the quality of soil used and fertilized in agricultural industry. The paper presents a new approach of using stable ESR spin labels to investigate a role of humic substances in the interactions of organic xenobiotic chemicals with constituents of natural soil via the typical functional groups of xenobiotics, such as Amines. At the experiment, the nitroxide spin labels, such as TEMPO (2,2,6,6-Tetramethylpiperidin-1-oxyl), Amino-TEMPO (4-amino-2,2,6,6-Tetramethylpiperidin-1-oxyl) and Aniline spin labels (2,5,5-Trimethyl-2-(3-aminophenyl)pyrrolidin-1-oxyl), were added to samples of different natural soils, such luvisol, cambisol and chernozem. Amino-TEMPO and Aniline spin labels include the aliphatic amino and aromatic amino functional groups, respectively. A significant broadening of the ESR spectrum of Aniline spin labels incubated in different soils indicated a stable effect of covalent binding of the spin labels to soil constituents via the aromatic amino, whereas the ESR spectra of the other two spin labels were not broadened that pointed at the absence of covalent binding of spin labels via the aliphatic amino. As shown, a part of bound spin labels via the aromatic amino increased with increasing of the concentration of humic acids in soil. The same broadened signals were also be detected with the humic acids extracted from the investigated soils. A strong covalent binding of spin labels to humic substances via the aromatic amines was

  12. Liquid state DNP for water accessibility measurements on spin-labeled membrane proteins at physiological temperatures

    Science.gov (United States)

    Doll, Andrin; Bordignon, Enrica; Joseph, Benesh; Tschaggelar, René; Jeschke, Gunnar

    2012-09-01

    We demonstrate the application of continuous wave dynamic nuclear polarization (DNP) at 0.35 T for site-specific water accessibility studies on spin-labeled membrane proteins at concentrations in the 10-100 μM range. The DNP effects at such low concentrations are weak and the experimentally achievable dynamic nuclear polarizations can be below the equilibrium polarization. This sensitivity problem is solved with an optimized home-built DNP probe head consisting of a dielectric microwave resonator and a saddle coil as close as possible to the sample. The performance of the probe head is demonstrated with both a modified pulsed EPR spectrometer and a dedicated CW EPR spectrometer equipped with a commercial NMR console. In comparison to a commercial pulsed ENDOR resonator, the home-built resonator has an FID detection sensitivity improvement of 2.15 and an electron spin excitation field improvement of 1.2. The reproducibility of the DNP results is tested on the water soluble maltose binding protein MalE of the ABC maltose importer, where we determine a net standard deviation of 9% in the primary DNP data in the concentration range between 10 and 100 μM. DNP parameters are measured in a spin-labeled membrane protein, namely the vitamin B12 importer BtuCD in both detergent-solubilized and reconstituted states. The data obtained in different nucleotide states in the presence and absence of binding protein BtuF reveal the applicability of this technique to qualitatively extract water accessibility changes between different conformations by the ratio of primary DNP parameters ɛ. The ɛ-ratio unveils the physiologically relevant transmembrane communication in the transporter in terms of changes in water accessibility at the cytoplasmic gate of the protein induced by both BtuF binding at the periplasmic region of the transporter and ATP binding at the cytoplasmic nucleotide binding domains.

  13. Spatial arrangement of rhodopsin in retinal rod outer segment membranes studied by spin-labeling and pulsed electron double resonance

    Energy Technology Data Exchange (ETDEWEB)

    Yasuda, Satoshi [Department of Biological Sciences, Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Department of Space and Earth Sciences, Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Hara, Hideyuki [Bruker Biospin, Yokohama, Kanagawa 215-0022 (Japan); Tokunaga, Fumio [Department of Space and Earth Sciences, Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Arata, Toshiaki, E-mail: arata@bio.sci.osaka-u.ac.jp [Department of Biological Sciences, Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Department of Space and Earth Sciences, Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan)

    2012-08-24

    Highlights: Black-Right-Pointing-Pointer Use of spin labeling and PELDOR to measure inter-rhodopsin distance in ROS. Black-Right-Pointing-Pointer Strong decay of PELDOR signal indicated a high density (mM range) of rhodopsin. Black-Right-Pointing-Pointer The decay was modeled by rhodopsin monomers dispersed in a planar membrane. -- Abstract: We have determined the spatial arrangement of rhodopsin in the retinal rod outer segment (ROS) membrane by measuring the distances between rhodopsin molecules in which native cysteines were spin-labeled at {approx}1.0 mol/mol rhodopsin. The echo modulation decay of pulsed electron double resonance (PELDOR) from spin-labeled ROS curved slightly with strong background decay. This indicated that the rhodopsin was densely packed in the retina and that the rhodopsin molecules were not aligned well. The curve was simulated by a model in which rhodopsin is distributed randomly as monomers in a planar membrane.

  14. Using spin labels to study molecular processes in soils: Covalent binding of aromatic amines to humic acids of soils

    Science.gov (United States)

    Aleksandrova, O. N.; Kholodov, V. A.; Perminova, I. V.

    2015-08-01

    Interactions of aliphatic and aromatic amines with soil and humic acids isolated from it are studied by means of spin labels and electron paramagnetic resonance (EPR) spectroscopy. Nitroxyl radicals containing amino groups are used as spin labels. It is found experimentally that aromatic amines are instantaneously converted to the bound state. It is shown that the microareas of their incorporation are characterized by a significant delay in the reduction of the nitroxyl fragment of spin-label molecules, indicating the formation of condensed structures typical of an oxidative binding mechanism. It is concluded that aliphatic amines do not bind to humic acids. It is noted that the studied process allows elucidating the formation of bound xenobiotic residues in soils.

  15. Gd(3+) Spin Labels Report the Conformation and Solvent Accessibility of Solution and Vesicle-Bound Melittin.

    Science.gov (United States)

    Manukovsky, Nurit; Frydman, Veronica; Goldfarb, Daniella

    2015-10-29

    Although Gd(3+)-based spin labels have been shown to be an alternative to nitroxides for double electron-electron resonance (DEER) distance measurements at high fields, their ability to provide solvent accessibility information, as nitroxides do, has not been explored. In addition, the effect of the label type on the measured distance distribution has not been sufficiently characterized. In this work, we extended the applicability of Gd(3+) spin labels to solvent accessibility measurements on a peptide in model membranes, namely, large unilamellar vesicles (LUVs) using W-band (2)H Mims electron-nuclear double resonance (ENDOR) and electron spin echo envelope modulation (ESEEM) techniques and Gd(3+)-ADO3A-labeled melittin. In addition, we carried out Gd(3+)-Gd(3+) DEER distance measurements to probe the peptide conformation in solution and when bound to LUVs. A comparison with earlier results reported for the same system with nitroxide labels shows that, although in both cases the peptide binds parallel to the membrane surface, the Gd(3+)-ADO3A label tends to protrude from the membrane into the solvent, whereas the nitroxide does the opposite. This can be explained on the basis of the hydrophilicity of the Gd(3+)-ADO3A labels in contrast with the hydrophobicity of nitroxides. The distance distributions obtained from different labels are accordingly different, with the Gd(3+)-ADO3A yielding consistently broader distributions. These discrepancies are most pronounced when the peptide termini are labeled, which implies that such labeling positions may be inadvisible. PMID:26001213

  16. [3H]Haloperidol labels brain dopamine receptors after its injection into the internal carotid artery of the rat

    International Nuclear Information System (INIS)

    Pulse injection of [3H]haloperidol (0.1 μCi; 0.003 μg) into the internal carotid artery of the rat specifically labelled dopamine receptors in striatum and olfactory tubercle, as indicated by the kinetics of, and the effects of neuroleptic drugs on, the ligand disposition. The described method may prove useful for labelling brain receptors with ligands which readily cross the blood-brain barrier but which do not selectively mark their receptors if injected systemically. (Auth.)

  17. Luminescence of the nitronyl nitroxide radical group in a spin-labelled pyrazolylquinoline

    International Nuclear Information System (INIS)

    The synthesis, structure and photoluminescence of a group of substituted 2-pyrazolylquinolines, including a spin-labelled derivative, are described. A comparative study of photoluminescence from the synthesized compounds demonstrates that introduction of a nitronyl nitroxide radical group results not only in the expected reduction in photoluminescence from the pyrazolylquinoline moiety, but also gives rise to a new red photoluminescence band (maximum at 692 nm in acetonitrile) from the radical fragment. -- Highlights: • The introduction of nitronyl nitroxide radical in 2-pyrazolylquinolines gives rise to new luminescence band at 692 nm. • The decrease of pyrazolylquinoline luminescence at 390 nm can be explained by intramolecular energy transfer to π-system of radical fragment. • Low quantum yield of 692 nm luminescence is determined by high rate constant of radiationless transition

  18. In vivo serial MR imaging of magnetically labeled endothelial progenitor cells homing to the endothelium injured artery in mice.

    Directory of Open Access Journals (Sweden)

    Jun Chen

    Full Text Available BACKGROUND: Emerging evidence of histopathological analyses suggests that endothelial progenitor cells (EPCs play an important role in vascular diseases. Neointimal hyperplasia can be reduced by intravenous transfusion of EPCs after vascular injury in mice. Therefore, it would be advantageous to develop an in vivo technique that can explore the temporal and spatial migration of EPCs homing to the damaged endothelium noninvasively. METHODOLOGY/PRINCIPAL FINDINGS: The left carotid common artery (LCCA was injured by removal of endothelium with a flexible wire in Kunming mice. EPCs were collected by in vitro culture of spleen-derived mouse mononuclear cells (MNCs. EPCs labeling was carried out in vitro using Fe₂O₃-poly-L-lysine (Fe₂O₃-PLL. In vivo serial MR imaging was performed to follow-up the injured artery at different time points after intravenous transfusion of EPCs. Vessel wall areas of injured artery were computed on T₂WI. Larger MR signal voids of vessel wall on T₂WI was revealed in all 6 mice of the labeled EPC transfusion group 15 days after LCCA injury, and it was found only in 1 mouse in the unlabeled EPC transfusion group (p = 0.015. Quantitative analyses of vessel wall areas on T₂WI showed that the vessel wall areas of labeled EPC transfusion group were less than those of unlabeled EPC transfusion group and control group fifteen days after artery injury (p<0.05. Histopathological analyses confirmed accumulation and distribution of transfused EPCs at the injury site of LCCA. CONCLUSIONS/SIGNIFICANCE: These data indicate that MR imaging might be used as an in vivo method for the tracking of EPCs homing to the endothelium injured artery.

  19. Site-Directed Spin-Labeling of Nucleic Acids by Click Chemistry. Detection of Abasic Sites in Duplex DNA by EPR Spectroscopy

    DEFF Research Database (Denmark)

    Sigurdsson, Snorri; Vogel, Stefan; Shelke, Sandip;

    2010-01-01

    This paper describes a spin label that can detect and identify local structural deformations in duplex DNA, in particular abasic sites. The spin label was incorporated into DNA by a new postsynthetic approach using click-chemistry on a solid support, which simplified both the synthesis and...

  20. Long-term MRI tracking of dual-labeled adipose-derived stem cells homing into mouse carotid artery injury

    Directory of Open Access Journals (Sweden)

    Qin JB

    2012-10-01

    Full Text Available Jin-Bao Qin,1,5,* Kang-An Li,2,* Xiang-Xiang Li,1,5 Qing-Song Xie,3 Jia-Ying Lin,4 Kai-Chuang Ye,1,5 Mi-Er Jiang,1,5 Gui-Xiang Zhang,2 Xin-Wu Lu1,51Department of Vascular Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University, School of Medicine, 2Department of Radiology, Shanghai First People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 3Department of Neurosurgery, Cixi Municipal People's Hospital, Zhejiang Province, China; 4Clinic for Gynecology, Charite-Universitatsmedizin Berlin, Berlin, Germany; 5Vascular Center, Shanghai Jiao Tong University, Shanghai, China*These two authors contributed equally to this workBackground: Stem cell therapy has shown great promise for regenerative repair of injured or diseased tissues. Adipose-derived stem cells (ADSCs have become increasingly attractive candidates for cellular therapy. Magnetic resonance imaging has been proven to be effective in tracking magnetic-labeled cells and evaluating their clinical relevance after cell transplantation. This study investigated the feasibility of imaging green fluorescent protein-expressing ADSCs (GFP-ADSCs labeled with superparamagnetic iron oxide particles, and tracked them in vivo with noninvasive magnetic resonance imaging after cell transplantation in a model of mouse carotid artery injury.Methods: GFP-ADSCs were isolated from the adipose tissues of GFP mice and labeled with superparamagnetic iron oxide particles. Intracellular stability, proliferation, and viability of the labeled cells were evaluated in vitro. Next, the cells were transplanted into a mouse carotid artery injury model. Clinical 3 T magnetic resonance imaging was performed immediately before and 1, 3, 7, 14, 21, and 30 days after cell transplantation. Prussian blue staining and histological analysis were performed 7 and 30 days after transplantation.Results: GFP-ADSCs were found to be efficiently labeled with superparamagnetic iron oxide

  1. Integrated analysis of the conformation of a protein-linked spin label by crystallography, EPR and NMR spectroscopy

    International Nuclear Information System (INIS)

    Long-range structural information derived from paramagnetic relaxation enhancement observed in the presence of a paramagnetic nitroxide radical is highly useful for structural characterization of globular, modular and intrinsically disordered proteins, as well as protein–protein and protein-DNA complexes. Here we characterized the conformation of a spin-label attached to the homodimeric protein CylR2 using a combination of X-ray crystallography, electron paramagnetic resonance (EPR) and NMR spectroscopy. Close agreement was found between the conformation of the spin label observed in the crystal structure with interspin distances measured by EPR and signal broadening in NMR spectra, suggesting that the conformation seen in the crystal structure is also preferred in solution. In contrast, conformations of the spin label observed in crystal structures of T4 lysozyme are not in agreement with the paramagnetic relaxation enhancement observed for spin-labeled CylR2 in solution. Our data demonstrate that accurate positioning of the paramagnetic center is essential for high-resolution structure determination.

  2. Use of spin labels to study membrane proteins by high-frequency electron nuclear double resonance spectroscopy

    NARCIS (Netherlands)

    Orlinkskii, S.B.; Borovykh, I.V.; Zielke, V.; Steinhoff, H.J.

    2007-01-01

    The applicability of spin labels to study membrane proteins by high-frequency electron nuclear double resonance spectroscopy is demonstrated. With the use of bacteriorhodopsin embedded in a lipid membrane as an example, the spectra of protons of neighboring amino acids are recorded, electric field g

  3. Conformational change in full-length mouse prion: A site-directed spin-labeling study

    International Nuclear Information System (INIS)

    The structure of the mouse prion (moPrP) was studied using site-directed spin-labeling electron spin resonance (SDSL-ESR). Since a previous NMR study by Hornemanna et al., [Hornemanna, Korthb, Oeschb, Rieka, Widera, Wuethricha, Glockshubera, Recombinant full-length murine prion protein, mPrP (23-231): purification and spectroscopic characterization, FEBS Lett. 413 (1997) 277-281] has indicated that N96, D143, and T189 in moPrP are localized in a Cu2+ binding region, Helix1 and Helix2, respectively, three recombinant moPrP mutations (N96C, D143C, and T189C) were expressed in an Escherichia coli system, and then refolded by dialysis under low pH and purified by reverse-phase HPLC. By using the preparation, we succeeded in preserving a target cystein residue without alteration of the α-helix structure of moPrP and were able to apply SDSL-ESR with a methane thiosulfonate spin label to the full-length prion protein. The rotational correlation times (τ) of 1.1, 3.3, and 4.8 ns were evaluated from the X-band ESR spectra at pH 7.4 and 20 deg C for N96R1, D143R1, and T189R1, respectively. τ reflects the fact that the Cu2+ binding region is more flexible than Helix1 or Helix2. ESR spectra recorded at various temperatures revealed two phases together with a transition point at around 20 deg C in D143R1 and T189R1, but not in N96R1. With the variation of pH from 4.0 to 7.8, ESR spectra of T189R1 at 20 deg C showed a gradual increase of τ from 2.9 to 4.8 ns. On the other hand, the pH-dependent conformational changes in N96R1 and D143R1 were negligible. These results indicated that T189 located in Helix2 possessed a structure sensitive to physiological pH changes; simultaneously, N96 in the Cu2+ binding region and D143 in Helix1 were conserved

  4. Location of the higher affinity copper site on human hemoglobin by the use of the spin label technique

    International Nuclear Information System (INIS)

    Addition of copper (II) ions to Cys β-93 maleimide spin-labelled human hemoglobin A produces a dramatic decrease in the amplitude of the spin-label ESR spectra. This effect was analyzed in the framework of Leigh's theory which permits interspin distances to be deduced from the effect of dipolar coupling on the ESR spectra and led to an estimate of 9A as the distance between the label and the higher affinity copper site. Taking into account the previous results which suggest that four nitrogen atoms coordinate with copper, and that the N terminal val β-1 and His β-2 residues are involved, the location of the higher affinity copper site is proposed to be at the β1 β2 interface of the hemoglobin molecule, involving the N terminal of one β subunit and the C terminal of the other. (Author)

  5. Impact of menaquinone-4 supplementation on coronary artery calcification and arterial stiffness: an open label single arm study

    OpenAIRE

    Ikari, Yuji; Torii, Sho; Shioi, Atsushi; Okano, Toshio

    2016-01-01

    Background Dietary intake of vitamin K has been reported to reduce coronary artery calcification (CAC) and cardiovascular events. However, it is unknown whether supplemental menaquinone (MK)-4 can reduce CAC or arterial stiffness. To study the effect of MK-4 supplementation on CAC and brachial ankle pulse wave velocity (baPWV). Methods This study is a single arm design to take 45 mg/day MK-4 daily as a therapeutic drug for 1 year. Primary endpoint was CAC score determined using 64-slice multi...

  6. Modeling structural transitions from the periplasmic-open state of lactose permease and interpretations of spin label experiments.

    Science.gov (United States)

    Zhuang, Xiaohong; Klauda, Jeffery B

    2016-07-01

    Lactose permease of E. coli (LacY) is a secondary active transporter (SAT) that belongs to the major facilitator superfamily (MFS). Experimental structures of the cytoplasmic-open and more recently occluded-like structure have been determined, however, the crystal structure of LacY in the periplasmic-open state is still not available. The periplasmic-open LacY structure is important for understanding complete proton/sugar transport process of LacY as well as other similar SAT proteins. Previously, a structural model of periplasmic-open LacY has been obtained through a two-step hybrid implicit-explicit (IM-EX) simulation method (JMB404: 506). Molecular dynamics simulations are performed to further test the IM-EX model for the periplasmic-open LacY with ββ-(Galp)2 in a lipid membrane. The comparison of the calculated pore radii to the data of the crystal structure indicates that the IM-EX model of LacY remains periplasmic-open in E269-protonated states. The neighbor residue distance change based on Cα are very similar in simulation results, but they are significantly different in double electron-electron resonance (DEER) experimental data, which motivates us to perform the molecular dynamics dummy spin-label (MDDS) simulations to test the effect of spin labels (size and internal flexibility) on DEER spin label distance measurements. The MDDS simulation results show that the orientation and movement of the spin labels significantly affect the residue pair distance measurement. DEER data alone may not provide an accurate guide for predicting protein structures. MDDS simulations can be applied to analyze the distance distribution due to spin labels and also aid in proper interpretation of DEER experimental data. PMID:27107553

  7. In vivo tracking of magnetically labeled mesenchmal stem cells injected via renal arteries in kidney failure rat

    International Nuclear Information System (INIS)

    Objective: To evaluate in vivo depiction and tracking for magnetically labeled bone marrow mesenchymal stern cells (MSCs) in a renal failure rat model injected intravascularly using a 1.5 T magnetic resonance imaging (MRI) system. Methods: Rat MSCs were isolated, purified, expanded and then incubated with home synthesized Fe2O3-PLL. Prussian blue stain was employed for identifying intracellular irons. An acute renal failure in rat was induced by intramuscular injection of glycerol and MSCs were injected into renal arteries of 11 recipients (labeled cells in six, unlabeled cells in five). MR images of kidneys were obtained respectively before injection of MSCs, and immediately, 1, 3, 5, and 8 clays after transplantation. MR imaging findings were analyzed, which were correlated with histological findings. Results: Rat MSCs were successfully labeled, and labeling efficiency was almost 100%. Prussian blue staining of Fe2O3-PLL labeled cells revealed the presence of iron-containing vesicles or endosomes in the cytoplasm. In the renal failure model of rats, the labeled MSCs were demonstrated as signal intensity loss in renal cortex on T2*-weighted MR images. The signal intensity decrease was visualized up to days 8 after transplantation. Histological analyses showed that most Prussian blue staining-positive cells were well correlated with the area where a signal intensity loss was observed in MRI. Signal intensity decrease was not detected after transplantation of unlabeled cells. Conclusion: The rat MSCs can be effectively labeled with Fe2O3-PLL. 1.5-T MR imaging seems to be a good technique to monitor the magnetically labeled MSCs in vivo in renal failure rat model intravascularly administered, which may have much more potential values for studying the engraftment of stem cells in kidneys. (authors)

  8. Orientation and lipid-peptide interactions of gramicidin A in lipid membranes: Polarized attenuated total reflection infrared spectroscopy and spin-label electron spin resonance

    OpenAIRE

    Kota, Z.; Pali, T.; Marsh, D.

    2004-01-01

    Gramicidin A was incorporated at a peptide/lipid ratio of 1:10 mol/mol in aligned bilayers of dimyristoyl phosphatidylcholine (DMPC), phosphatidylserine (DMPS), phosphatidylglycerol (DMPG), and phosphatidylethanolamine (DMPE), from trifluoroethanol. Orientations of the peptide and lipid chains were determined by polarized attenuated total reflection infrared spectroscopy. Lipid-peptide interactions with gramicidin A in DMPC bilayers were studied with different spin-labeled lipid species by us...

  9. Communication: Orientational self-ordering of spin-labeled cholesterol analogs in lipid bilayers in diluted conditions

    Science.gov (United States)

    Kardash, Maria E.; Dzuba, Sergei A.

    2014-12-01

    Lipid-cholesterol interactions are responsible for different properties of biological membranes including those determining formation in the membrane of spatial inhomogeneities (lipid rafts). To get new information on these interactions, electron spin echo (ESE) spectroscopy, which is a pulsed version of electron paramagnetic resonance (EPR), was applied to study 3β-doxyl-5α-cholestane (DCh), a spin-labeled analog of cholesterol, in phospholipid bilayer consisted of equimolecular mixture of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine and 1,2-dioleoyl-sn-glycero-3-phosphocholine. DCh concentration in the bilayer was between 0.1 mol.% and 4 mol.%. For comparison, a reference system containing a spin-labeled 5-doxyl-stearic acid (5-DSA) instead of DCh was studied as well. The effects of "instantaneous diffusion" in ESE decay and in echo-detected (ED) EPR spectra were explored for both systems. The reference system showed good agreement with the theoretical prediction for the model of spin labels of randomly distributed orientations, but the DCh system demonstrated remarkably smaller effects. The results were explained by assuming that neighboring DCh molecules are oriented in a correlative way. However, this correlation does not imply the formation of clusters of cholesterol molecules, because conventional continuous wave EPR spectra did not show the typical broadening due to aggregation of spin labels and the observed ESE decay was not faster than in the reference system. So the obtained data evidence that cholesterol molecules at low concentrations in biological membranes can interact via large distances of several nanometers which results in their orientational self-ordering.

  10. Communication: Orientational self-ordering of spin-labeled cholesterol analogs in lipid bilayers in diluted conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kardash, Maria E.; Dzuba, Sergei A., E-mail: dzuba@kinetics.nsc.ru [Voevodsky Institute of Chemical Kinetics and Combustion, 630090 Novosibirsk, Russia, and Novosibirsk State University, 630090 Novosibirsk (Russian Federation)

    2014-12-07

    Lipid-cholesterol interactions are responsible for different properties of biological membranes including those determining formation in the membrane of spatial inhomogeneities (lipid rafts). To get new information on these interactions, electron spin echo (ESE) spectroscopy, which is a pulsed version of electron paramagnetic resonance (EPR), was applied to study 3β-doxyl-5α-cholestane (DCh), a spin-labeled analog of cholesterol, in phospholipid bilayer consisted of equimolecular mixture of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine and 1,2-dioleoyl-sn-glycero-3-phosphocholine. DCh concentration in the bilayer was between 0.1 mol.% and 4 mol.%. For comparison, a reference system containing a spin-labeled 5-doxyl-stearic acid (5-DSA) instead of DCh was studied as well. The effects of “instantaneous diffusion” in ESE decay and in echo-detected (ED) EPR spectra were explored for both systems. The reference system showed good agreement with the theoretical prediction for the model of spin labels of randomly distributed orientations, but the DCh system demonstrated remarkably smaller effects. The results were explained by assuming that neighboring DCh molecules are oriented in a correlative way. However, this correlation does not imply the formation of clusters of cholesterol molecules, because conventional continuous wave EPR spectra did not show the typical broadening due to aggregation of spin labels and the observed ESE decay was not faster than in the reference system. So the obtained data evidence that cholesterol molecules at low concentrations in biological membranes can interact via large distances of several nanometers which results in their orientational self-ordering.

  11. Communication: Orientational self-ordering of spin-labeled cholesterol analogs in lipid bilayers in diluted conditions

    International Nuclear Information System (INIS)

    Lipid-cholesterol interactions are responsible for different properties of biological membranes including those determining formation in the membrane of spatial inhomogeneities (lipid rafts). To get new information on these interactions, electron spin echo (ESE) spectroscopy, which is a pulsed version of electron paramagnetic resonance (EPR), was applied to study 3β-doxyl-5α-cholestane (DCh), a spin-labeled analog of cholesterol, in phospholipid bilayer consisted of equimolecular mixture of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine and 1,2-dioleoyl-sn-glycero-3-phosphocholine. DCh concentration in the bilayer was between 0.1 mol.% and 4 mol.%. For comparison, a reference system containing a spin-labeled 5-doxyl-stearic acid (5-DSA) instead of DCh was studied as well. The effects of “instantaneous diffusion” in ESE decay and in echo-detected (ED) EPR spectra were explored for both systems. The reference system showed good agreement with the theoretical prediction for the model of spin labels of randomly distributed orientations, but the DCh system demonstrated remarkably smaller effects. The results were explained by assuming that neighboring DCh molecules are oriented in a correlative way. However, this correlation does not imply the formation of clusters of cholesterol molecules, because conventional continuous wave EPR spectra did not show the typical broadening due to aggregation of spin labels and the observed ESE decay was not faster than in the reference system. So the obtained data evidence that cholesterol molecules at low concentrations in biological membranes can interact via large distances of several nanometers which results in their orientational self-ordering

  12. Site directed spin labeling studies of Escherichia coli dihydroorotate dehydrogenase N-terminal extension

    Energy Technology Data Exchange (ETDEWEB)

    Couto, Sheila G. [Instituto de Fisica de Sao Carlos, Universidade de Sao Paulo, Av. Trabalhador Sao-carlense 400, C.P. 369, 13560-970, Sao Carlos, SP (Brazil); Grupo de Biofisica e Fisica Aplicada a Medicina, Instituto de Fisica, Universidade Federal de Goias, Campus Samambaia, C.P. 131, 74001-970, Goiania, GO (Brazil); Cristina Nonato, M. [Laboratorio de Cristalografia de Proteinas, Faculdade de Ciencias Farmaceuticas de Ribeirao Preto, Universidade de Sao Paulo, Av. do Cafe S/N, 14040-903, Ribeirao Preto, SP (Brazil); Costa-Filho, Antonio J., E-mail: ajcosta@ffclrp.usp.br [Instituto de Fisica de Sao Carlos, Universidade de Sao Paulo, Av. Trabalhador Sao-carlense 400, C.P. 369, 13560-970, Sao Carlos, SP (Brazil); Departamento de Fisica, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Av. Bandeirantes 3900, 14040-901, Ribeirao Preto, SP (Brazil)

    2011-10-28

    Highlights: Black-Right-Pointing-Pointer EcDHODH is a membrane-associated enzyme and a promising target for drug design. Black-Right-Pointing-Pointer Enzyme's N-terminal extension is responsible for membrane association. Black-Right-Pointing-Pointer N-terminal works as a molecular lid regulating access to the protein interior. -- Abstract: Dihydroorotate dehydrogenases (DHODHs) are enzymes that catalyze the fourth step of the de novo synthesis of pyrimidine nucleotides. In this reaction, DHODH converts dihydroorotate to orotate, using a flavine mononucleotide as a cofactor. Since the synthesis of nucleotides has different pathways in mammals as compared to parasites, DHODH has gained much attention as a promising target for drug design. Escherichia coli DHODH (EcDHODH) is a family 2 DHODH that interacts with cell membranes in order to promote catalysis. The membrane association is supposedly made via an extension found in the enzyme's N-terminal. In the present work, we used site directed spin labeling (SDSL) to specifically place a magnetic probe at positions 2, 5, 19, and 21 within the N-terminal and thus monitor, by using Electron Spin Resonance (ESR), dynamics and structural changes in this region in the presence of a membrane model system. Overall, our ESR spectra show that the N-terminal indeed binds to membranes and that it experiences a somewhat high flexibility that could be related to the role of this region as a molecular lid controlling the entrance of the enzyme's active site and thus allowing the enzyme to give access to quinones that are dispersed in the membrane and that are necessary for the catalysis.

  13. A novel electron paramagnetic resonance spin label and its application to study the cross-bridge cycle.

    OpenAIRE

    Raucher, D; Fajer, E A; Sár, C; Hideg, K; Zhao, Y.; Kawai, M; Fajer, P G

    1995-01-01

    We have used a novel alpha-iodoketone spin-label (IKSL) to study myosin head orientation and cross-bridge dynamics in the putative pre-powerstroke state. Possible perturbation of the cross-bridge cycle by the label was assayed by the sinusoidal analysis method (Kawai and Brandt, 1980; Kawai and Zhao, 1993), which determines the rate constants of the elementary steps in the cycle. A comparison of the rates obtained from unlabeled and IKSL fibers revealed small (10-20%) changes in the ATP hydro...

  14. Renal arterial spin labeling magnetic resonance imaging in normal adults:a study with a 3.0 T scanner%3.0T磁共振动脉自旋标记技术在正常成人肾脏检查中的应用

    Institute of Scientific and Technical Information of China (English)

    张帆; 张雪林; 杨立; 沈洁; 高伟

    2013-01-01

    目的分析单次激发快速自旋回波-流动敏感反转恢复序列(SSFSE-FAIR)与平面回波-流动敏感反转恢复序列(EPI-FAIR)所测量的健康肾脏的相对血流量值(rBFV),评价两种动脉自旋标记(ASL)序列在正常肾脏检查中的应用价值。方法前瞻性分析40例符合纳入标准的受试者的rBFV。采用3.0T磁共振扫描仪扫描。按3种方式采集图像:EPI-FAIR屏气法、SSFSE-FAIR屏气法及SSFSE-FAIR自由呼吸法。结果SSFSE-FAIR自由呼吸法可定量区分肾脏皮髓质。皮质rBFV:111.48±9.23;髓质rBFV:94.98±3.38;SSFSE-FAIR屏气法及EPI-FAIR不能定量区分肾脏皮髓质。EPI-FAIR皮髓平均rBFV为178.50±17.17,95%置信区间:167.59~189.41。结论 SSFSE-FAIR屏气法及EPI-FAIR空间分辨率低,无法区分肾脏皮髓质,可粗略评价肾脏灌注情况。SSFSE-FAIR图像空间分辨率较高,可区分肾脏皮髓质结构,可初步评判肾脏皮髓质的灌注状态。%Objective To analyze the renal relative blood flow value (rBFV) and image quality in normal adults using single-shot fast spin echo, flow sensitive invention recovery (SSFSE-FAIR) magnetic resonance (MR) sequence and echo planar imaging, and flow sensitive invention recovery (EPI-FAIR) MR sequence, and assess its value for clinical application in routine renal examination. Methods Forty volunteers (25 male and 15 female adults, aged 30 to 62 years) with normal renal function were included in this prospective study. All the subjects underwent 3.0 Tesla MR scanning using 3 MR scan modes, namely breath-holding EPI-FAIR, breath-holding SSFSE-FAIR and free breathing SSFSE-FAIR. Results SSFSE-FAIR without breath-holding was capable of differentiating the renal cortex and medulla with the corresponding rBFVs of 111.48 ± 9.23 and 94.98 ± 3.38, respectively. Breath-holding SSFSE-FAIR and EPI-FAIR failed to distinguish the borders of the renal cortex and medulla. The EPI-FAIR rBFV of mixed

  15. Use of spin labels to evaluate effects of cold shock and osmolality on sperm

    Energy Technology Data Exchange (ETDEWEB)

    Hammerstedt, R.H.; Keith, A.D.; Snipes, W.; Amann, R.P.; Arruda, D.; Griel, L.C. Jr.

    1978-05-01

    Spin labels were used to evaluate the effects of butylated hydroxytoluene (BHT), rapid cooling to 0/sup 0/C and osmolality on the integrity of sperm membranes. In vitro incubation of rabbit sperm with 0.5 mM BHT prior to artificial insemination did not alter the fertilizing ability of the sperm. Sperm from 6 species were ranked in terms of susceptibility to membrane damage caused by rapid cooling to 0/sup 0/C. The integrity of bull and ram sperm membranes was destroyed by the rapid cooling; BHT protected membranes of these spermatozoa from cold-induced lysis. Boar sperm membranes were porous after rapid cooling and BHT did not prevent this membrane damage. Membranes of rabbit and rooster sperm were not damaged by rapid cooling to 0/sup 0/C. Stallion sperm could not be analyzed because their membranes were altered by addition of reagents necessary to use the technique. The responses of bull, ram and rabbit sperm membranes to hyper- and hypo-osmotic conditions were determined. Hypotonic treatment (less than 200 mOsm) resulted in a 50 percent expansion of the volume of the aqueous compartment of sperm while hypertonic (700 mOsm) conditions compressed the volume of the aqueous compartment to 25 to 30 percent of the volume measured at 300 mOsm. Bull sperm, but not rabbit or ram sperm, responded as ''perfect osmometers'' between 300 and 700 mOsm.

  16. Deuterium Nuclear Spin-Lattice Relaxation Times and Quadrupolar Coupling Constants in Isotopically Labeled Saccharides

    Science.gov (United States)

    Bose-Basu, Bidisha; Zajicek, Jaroslav; Bondo, Gail; Zhao, Shikai; Kubsch, Meredith; Carmichael, Ian; Serianni, Anthony S.

    2000-06-01

    13C and 2H spin-lattice relaxation times have been determined by inversion recovery in a range of site-specific 13C- and 2H-labeled saccharides under identical solution conditions, and the data were used to calculate deuterium nuclear quadrupolar coupling constants (2H NQCC) at specific sites within cyclic and acyclic forms in solution. 13C T1 values ranged from ∼0.6 to 8.2 s, and 2H T1 values ranged from ∼79 to 450 ms, depending on molecular structure (0.4 M sugar in 5 mM EDTA (disodium salt) in 2H2O-depleted H2O, pH 4.8, 30°C). In addition to providing new information on 13C and 2H relaxation behavior of saccharides in solution, the resulting 2H1 NQCC values reveal a dependency on anomeric configuration within aldopyranose rings, whereas 2H NQCC values at other ring sites appear less sensitive to configuration at C1. In contrast, 2H NQCC values at both anomeric and nonanomeric sites within aldofuranose rings appear to be influenced by anomeric configuration. These experimental observations were confirmed by density functional theory (DFT) calculations of 2H NQCC values in model aldopyranosyl and aldofuranosyl rings.

  17. Site Directed Spin Labeling and EPR Spectroscopic Studies of Pentameric Ligand-Gated Ion Channels.

    Science.gov (United States)

    Basak, Sandip; Chatterjee, Soumili; Chakrapani, Sudha

    2016-01-01

    Ion channel gating is a stimulus-driven orchestration of protein motions that leads to transitions between closed, open, and desensitized states. Fundamental to these transitions is the intrinsic flexibility of the protein, which is critically modulated by membrane lipid-composition. To better understand the structural basis of channel function, it is necessary to study protein dynamics in a physiological membrane environment. Electron Paramagnetic Resonance (EPR) spectroscopy is an important tool to characterize conformational transitions between functional states. In comparison to NMR and X-ray crystallography, the information obtained from EPR is intrinsically of lower resolution. However, unlike in other techniques, in EPR there is no upper-limit to the molecular weight of the protein, the sample requirements are significantly lower, and more importantly the protein is not constrained by the crystal lattice forces. Therefore, EPR is uniquely suited for studying large protein complexes and proteins in reconstituted systems. In this article, we will discuss general protocols for site-directed spin labeling and membrane reconstitution using a prokaryotic proton-gated pentameric Ligand-Gated Ion Channel (pLGIC) from Gloeobacter violaceus (GLIC) as an example. A combination of steady-state Continuous Wave (CW) and Pulsed (Double Electron Electron Resonance-DEER) EPR approaches will be described that will enable a complete quantitative characterization of channel dynamics. PMID:27403967

  18. Deep arterial injury during experimental angioplasty: relation to a positive indium-111-labeled platelet scintigram, quantitative platelet deposition and mural thrombosis

    International Nuclear Information System (INIS)

    Although it is not clear why coronary occlusion and restenosis occur after successful coronary angioplasty, factors related to the procedure may influence early and late results. The possible adverse effects of a medial tear documented histologically and produced during balloon angioplasty of the common carotid arteries were studied in 30 fully heparinized (100 U/kg body weight) normal pigs. Scanning electron microscopy showed endothelial denudation and extensive platelet deposition in all dilated arterial segments. Visible macroscopic mural thrombus was present within an hour of the procedure in 29 (91%) of the 32 arteries that had a medial tear documented by histologic study; the tear produced an indium-111-labeled platelet deposition of 116.4 +/- 26.5 X 10(6)/cm2 (mean +/- SE) and total thrombotic occlusion in 2 arteries (4%). None of the 24 arteries without a medial tear had a thrombus, and the mean platelet deposition in that group was 7.0 +/- 0.5 X 10(6)/cm2 (p less than 0.0008). In 12 pigs scanned with a gamma camera, visible thrombus was associated with platelet deposition in excess of 20 X 10(6)/cm2 in 12 arteries, 9 of which had a positive indium-111-labeled platelet scintigram. Thus, arterial angioplasty causes deep arterial injury, which appears to be a major cause of mural thrombosis, heavy platelet deposition, a positive indium-111-labeled platelet scintigram and acute arterial occlusion. A positive indium-111-labeled platelet scintigram was always associated with macroscopic thrombus of at least 20 > 10(6) platelets/cm2 and underlying deep arterial injury

  19. Effects of AMPPNP on the orientation and rotational dynamics of spin-labeled muscle cross-bridges.

    OpenAIRE

    Fajer, P G; Fajer, E A; Brunsvold, N J; Thomas, D. D.

    1988-01-01

    We have used electron paramagnetic resonance (EPR) to investigate the orientation, rotational motion, and actin-binding properties of rabbit psoas muscle cross-bridges in the presence of the nonhydrolyzable nucleotide analogue, 5'-adenylylimido-diphosphate (AMPPNP). This analogue is known to decrease muscle tension without affecting its stiffness, suggesting an attached cross-bridge state different from rigor. We spin-labeled the SH1 groups on myosin heads and performed conventional EPR to ob...

  20. Comparing continuous wave progressive saturation EPR and time domain saturation recovery EPR over the entire motional range of nitroxide spin labels.

    Science.gov (United States)

    Nielsen, Robert D; Canaan, Stephane; Gladden, James A; Gelb, Michael H; Mailer, Colin; Robinson, Bruce H

    2004-07-01

    The measurement of spin-lattice relaxation rates from spin labels, such as nitroxides, in the presence and absence of spin relaxants provides information that is useful for determining biomolecular properties such as nucleic acid dynamics and the interaction of proteins with membranes. We compare X-band continuous wave (CW) and pulsed or time domain (TD) EPR methods for obtaining spin-lattice relaxation rates of spin labels across the entire range of rotational motion to which relaxation rates are sensitive. Model nitroxides and spin-labeled biological species are used to illustrate the potential complications that arise in extracting relaxation data under conditions typical to biological experiments. The effect of super hyperfine (SHF) structure is investigated for both CW and TD spectra. First and second harmonic absorption and dispersion CW spectra of the nitroxide spin label, TEMPOL, are all fit simultaneously to a model of SHF structure over a range of microwave amplitudes. The CW spectra are novel because all harmonics and microwave phases were acquired simultaneously using our homebuilt CW/TD spectrometer. The effect of the SHF structure on the pulsed free induction decay (FID) and pulsed saturation recovery spectrum is shown for both protonated and deuterated TEMPOL. We present novel pulsed saturation recovery measurements on biological molecules, including spin-lattice relaxation rates of spin-labeled proteins and spin-labeled double-stranded DNA. The impact of structure and dynamics on relaxation rates are discussed in the context of each of these examples. Collisional relaxation rates with oxygen and transition metal paramagnetic relaxants are extracted using both continuous wave and time domain methods. The extent of the errors inherent in the CW method and the advantages of pulsed methods for unambiguously measuring collisional relaxation rates are discussed. Spin-lattice relaxation rates, determined by both CW and pulsed methods, are used to determine

  1. Correlation between the rate of bioreduction of nitroxide spin label by human tumor cells and their low-dose radiation response

    International Nuclear Information System (INIS)

    The authors discuss a correlation observed between the bioreduction of nitroxide spin label by four human tumor cell lines and a normal tissue fibroblast clone and their low-dose radiation response, specifically their DQ. In measurements of the bioreduction rate of several other cell lines, this correlation appears to persist. In order to define the mechanism of this correlation, they have begun by subtly altering the measurement conditions. The original conditions for measurement involved adding the spin label to cells whose culture medium had been changed (the label was added to the new medium). By delaying the addition of the label to the culture medium, they substantially reduced the variation of the bioreduction rate between the cell lines. This implies that the fresh medium provides a nonspecific irritant or disequilibrium to the cultured cell system to which they response variably by accelerating, among other things, the metabolic process responsible for spin label bioreduction

  2. RELATIONSHIP BETWEEN EFFICENCIES OF SEGMENTAL HEPATIC ARTERY CHEMOEMBOLIZATION AND PCNA LABELING INDEX IN HCC

    Institute of Scientific and Technical Information of China (English)

    李玉亮; 邵广瑞

    2004-01-01

    Objective: To evaluate the relationship between the efficiencies of subsegmental TAE and the expression of PCNA with ABC immunohistochemical staining in HCCs. Methods: Ultrasound-guided needle biopsies were performed in 43 patients (41 men, 2 women; age range: 32~75 years, mean, 55.6 years). PCNA were examined using ABC immunohistochemical staining. Tumor scores of PCNA were assessed by counting the positive nuclei per 1,000 cells. All the cases received subsegmental TAE with iodized oil and gelatin sponge. A correlation between the expression of PCNA and the efficiencies of subsegmental TAE was sought. Normality test, rank sum test and Chi-square test were used in statistical analyses with SAS package. Results: The mean PCNA labeling index was 58±29(range, 27-100%) in 43 patients. When compared with the macroscopic and pathologic parameters, PCNA labeling index was found to be significantly related to the presence and activity of cirrhosis. PCNA labeling index did not related to patients' age, sex, HbsAg status or serum α-fetoprotein level. The PCNA labeling index corresponded to the degree of histological differentiation (Edmenderson- Steiner grading). The survival rates after subsegmental TAE were respectively 86.05%, 65.12% and 51.16% in one-, two- and three-years, and were significantly higher in the low labeling index group than that in the high labeling index group. Conclusion: The PCNA labeling index was shown to be closely related to histological characteristics and survival of the patients.

  3. Design, Synthesis, EPR-Studies and Conformational Bias of Novel Spin-Labeled DCC-Analogues for the Highly Regioselective Labeling of Aliphatic and Aromatic Carboxylic Acids.

    Science.gov (United States)

    Gölz, Jan Philipp; NejatyJahromy, Yaser; Bauer, Mirko; Muhammad, Ashraf; Schnakenburg, Gregor; Grimme, Stefan; Schiemann, Olav; Menche, Dirk

    2016-07-01

    Novel types of spin-labeled N,N'-dicyclohexylcarbodiimides (DCC) are reported that bear a 2,2,6,6-tetramethylpiperidinyloxyl (TEMPO) residue on one side and different aromatic and aliphatic cyclohexyl analogues on the other side of the diimide core. These readily available novel reagents add efficiently to aliphatic and aromatic carboxylic acids, forming two possible spin-labeled amide derivatives with different radical distances of the resulting amide. The addition of aromatic DCC analogues proceeds with excellent selectivity, giving amides where the carboxylic acid is exclusively connected to the aromatic residue, while little or no selectivity was observed for the aliphatic congeners. The usefulness of these adducts in structural studies was demonstrated by EPR (electron paramagnetic resonance) measurements of biradical adducts of biphenyl-4,4'-dicarboxylic acids. These analyses also reveal high degrees of conformational bias for aromatic DCC derivatives, which further underlines the powerfulness of these novel reagents. This observation was further corroborated by quantum chemical calculations, giving a detailed understanding of the structural dynamics, while detailed information on the solid state structure of all novel reagents was obtained by X-ray structure analyses. PMID:27272435

  4. Contrast optimization in multiphase arterial spin labeling; Otimizacao do contraste em ASL multi-fase

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Fernando F.; Paschoal, Andre M., E-mail: paiva@ifsc.usp.br [Universidade de Sao Paulo (CIERMag/USP), Sao Carlos, SP (Brazil). Instituto de Fisica; Foerster, Bernd U. [Philips Medical Systems LatAm, Sao Paulo, SP (Brazil); Tovar-Moll, Fernanda; Moll, Jorge [Instituto D' Or de Pesquisa e Ensino, Rio de Janeiro, RJ (Brazil)

    2013-08-15

    Multiphase ASL is an effective way to overcome the regional variation of the transit time that difficult the estimation of perfusion values. However, with conventional multiple phases ASL techniques, the ASL contrast at later phases is impaired due to repeated application of excitation pulses and longitudinal relaxation making it difficult to evaluate the tissue perfusion in regions where the transit time is longer. In the present study, we show an improvement of the acquisition scheme by exploring a modulation on the flip angle of the MR acquisition to keep the ASL contrast constant over multiple phases. (author)

  5. Lateral Ordering of Lipid Chains in Cholesterol-Containing Membranes: High-Field Spin-Label EPR

    Science.gov (United States)

    Kurad, Dieter; Jeschke, Gunnar; Marsh, Derek

    2004-01-01

    High-field (i.e., 94 GHz) electron paramagnetic resonance is used to characterize the nonaxial ordering of spin-labeled lipid chains in membranes containing cholesterol. Employing high magnetic fields (and microwave frequencies) allows investigation of both the lateral and transverse ordering of the phospholipid chains by cholesterol, from the x-y and z-elements, respectively, of the spin-label g-tensor. Transverse ordering is described by the conventional order parameter, 〈P2(cosβ)〉, where β is the instantaneous inclination of the chain axis to the membrane normal; and lateral ordering is described by the order parameter 〈cos2(φ − \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} \\begin{equation*}{\\bar {{\\phi}}}\\end{equation*}\\end{document})〉, where φ is the azimuthal angle about the chain axis and \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} \\begin{equation*}{\\bar {{\\phi}}}\\end{equation*}\\end{document} is the mean azimuthal orientation about which angular fluctuations take place. To obtain high positional resolution, phosphatidylcholines spin labeled at all odd and even positions from n = 4 to n = 14 in the sn-2 chain (1-acyl-2-[n-(4,4′-dimethyloxazolidine-N-oxyl)]stearoyl-sn-glycero-3-phosphocholine) are used at probe amounts in membranes of dimyristoyl phosphatidylcholine containing either high (40 mol %) or low (5 mol %) concentrations of cholesterol. At high-cholesterol content, lateral ordering of the spin-labeled lipid chains is detected over a wide range of temperature throughout the liquid-ordered phase. The transverse profile of lateral φ-ordering with position, n, of chain labeling follows

  6. Librational Motion of Spin-Labeled Lipids in High-Cholesterol Containing Membranes from Echo-Detected EPR Spectra

    Science.gov (United States)

    Erilov, Denis A.; Bartucci, Rosa; Guzzi, Rita; Marsh, Derek; Dzuba, Sergei A.; Sportelli, Luigi

    2004-01-01

    Two-pulse, echo-detected (ED) electron paramagnetic resonance (EPR) spectroscopy was used to study the librational motions of spin-labeled lipids in membranes of dipalmitoylphosphatidylcholine + 50 mol % cholesterol. The temperature dependence, over the range 77–240 K, and the dependence on position of spin-labeling in the sn-2 chain (n = 5, 7, 10, 12, and 14) of the phospholipid, were characterized in detail. The experimental ED-spectra were corrected for instantaneous spin diffusion arising from static spin-spin interactions, by using spectra recorded at 77 K, where motional contributions are negligible. Simulations according to a model of rapid, small-amplitude librations about an axis whose direction is randomly distributed are able to describe the experimental spectra. Calibrations, in terms of the amplitude-correlation time product, 〈α2〉τc, were constructed for diagnostic spectral line-height ratios at different echo delay times, and for relaxation spectra obtained from the ratio of ED-spectra recorded at two different echo delays. The librational amplitude, 〈α2〉, was determined for a spin label at the 14-C position of the lipid chain from the partially motionally averaged hyperfine splitting in the conventional EPR spectra. The librational correlation time, τc, which is deduced from combination of the conventional and ED-EPR results, lies in the subnanosecond regime and depends only weakly on temperature. The temperature dependence of the ED-EPR spectra arises mainly from an increase in librational amplitude with increasing temperature, and position down the lipid chain. A gradual transition takes place at higher temperatures, from a situation in which segmental torsional librations are cumulative, i.e., the contributions of the individual segments add up progressively upon going down the chain, to one of concerted motion only weakly dependent on chain position. Such librational motions are important for glass-like states and are generally

  7. Interaction of bee venom melittin with zwitterionic and negatively charged phospholipid bilayers : a spin-label electron spin resonance study

    OpenAIRE

    Kleinschmidt, Jörg H.; Mahaney, James E.; Thomas, David D.; Marsh, Derek

    1997-01-01

    Electron spin resonance (ESR) spectroscopy was used to study the penetration and interaction of bee venom melittin with dimyristoylphosphatidylcholine (DMPC) and ditetradecylphosphatidylglycerol (DTPG) bilayer membranes. Melittin is a surface-active, amphipathic peptide and serves as a useful model for a variety of membrane interactions, including those of presequences and signal peptides, as well as the charged subdomain of the cardiac regulatory protein phospholamban. Derivatives of phospha...

  8. Fluidity of chicken ventricular plasma membranes during development in-ovo and after birth: spin labelling and fluorescence studies.

    Science.gov (United States)

    Daveloose, D; Vezin, H; Basse, F; Viret, J

    1993-12-01

    The fluidity of isolated chicken ventricular plasma membranes was investigated by ESR spectroscopy, using three doxylstearic spin labels (5-SASL, 10-SASL and 16-SASL), and by fluorescence anisotropy measurements, using DPH probe. The analysis of 2T1 splitting constant and rotational correlation frequency have shown differences, during in-ovo development, characterized by a rigidification phase with a maximum at 19 days of development, just before hatching, followed by a fluidification phase after birth. These phenomena were also improved by DPH fluorescence and dynamical analysis of the hydrophobic 16-SASL probe. PMID:8158663

  9. High-frequency, spin-label EPR of nonaxial lipid ordering and motion in cholesterol-containing membranes

    Science.gov (United States)

    Gaffney, Betty J.; Marsh, Derek

    1998-01-01

    The EPR spectra of spin-labeled lipid chains in fully hydrated bilayer membranes of dimyristoyl phosphatidylcholine containing 40 mol % of cholesterol have been studied in the liquid-ordered phase at a microwave radiation frequency of 94 GHz. At such high field strengths, the spectra should be optimally sensitive to lateral chain ordering that is expected in the formation of in-plane domains. The high-field EPR spectra from random dispersions of the cholesterol-containing membranes display very little axial averaging of the nitroxide g-tensor anisotropy for lipids spin labeled toward the carboxyl end of the sn-2 chain (down to the 8-C atom). For these positions of labeling, anisotropic 14N-hyperfine splittings are resolved in the gzz and gyy regions of the nonaxial EPR spectra. For positions of labeling further down the lipid chain, toward the terminal methyl group, the axial averaging of the spectral features systematically increases and is complete at the 14-C atom position. Concomitantly, the time-averaged 〈Azz〉 element of the 14N-hyperfine tensor decreases, indicating that the axial rotation at the terminal methyl end of the chains arises from correlated torsional motions about the bonds of the chain backbone, the dynamics of which also give rise to a differential line broadening of the 14N-hyperfine manifolds in the gzz region of the spectrum. These results provide an indication of the way in which lateral ordering of lipid chains in membranes is induced by cholesterol. PMID:9789019

  10. Protein kinase C activation and myosin light chain phosphorylation in 32P-labeled arterial smooth muscle

    International Nuclear Information System (INIS)

    Experiments using 32P-labeled strips of swine carotid artery medial smooth muscle were performed to define the relative contribution of myosin light chain (MLC) phosphorylation as an activation mechanism mediating contractile responses stimulated by phorbol dibutyrate (PDB). Tryptic phosphopeptide mapping of phosphorylated MLC indicated that near-maximal force responses were associated with increases in functional MLC phosphorylation of less than 10% of the total MLC content following tonic (45 min) stimulation by PDB. Significant phosphorylation of MLC residues, consistent with the specificity of protein kinase C, occurred in response to high concentrations of PDB (greater than 0.1 microM). Histamine (10 microM)-induced MLC phosphorylation after 2 min (72.5% of total MLC) or 45 min (61.7%) was restricted to serine residues on peptides thought to contain serine19. Although agonist (histamine)-induced responses were eliminated under conditions of Ca2+ depletion, near-maximal force in response to 10 microM PDB (89.4% of a standard KCl response) was associated with monophosphorylation of less than 9% of the total MLC on peptides interpreted as containing serine19. A substantial fraction of this was localized to threonine residues. The quantitative analysis of the relation between PDB-stimulated force and the residues in MLC phosphorylated supports the concept that PDB stimulation results in activation of arterial smooth muscle cross bridges by MLC-phosphorylation-independent mechanisms

  11. Protein kinase C activation and myosin light chain phosphorylation in sup 32 P-labeled arterial smooth muscle

    Energy Technology Data Exchange (ETDEWEB)

    Singer, H.A. (Geisinger Clinic, Danville, PA (USA))

    1990-10-01

    Experiments using 32P-labeled strips of swine carotid artery medial smooth muscle were performed to define the relative contribution of myosin light chain (MLC) phosphorylation as an activation mechanism mediating contractile responses stimulated by phorbol dibutyrate (PDB). Tryptic phosphopeptide mapping of phosphorylated MLC indicated that near-maximal force responses were associated with increases in functional MLC phosphorylation of less than 10% of the total MLC content following tonic (45 min) stimulation by PDB. Significant phosphorylation of MLC residues, consistent with the specificity of protein kinase C, occurred in response to high concentrations of PDB (greater than 0.1 microM). Histamine (10 microM)-induced MLC phosphorylation after 2 min (72.5% of total MLC) or 45 min (61.7%) was restricted to serine residues on peptides thought to contain serine19. Although agonist (histamine)-induced responses were eliminated under conditions of Ca2+ depletion, near-maximal force in response to 10 microM PDB (89.4% of a standard KCl response) was associated with monophosphorylation of less than 9% of the total MLC on peptides interpreted as containing serine19. A substantial fraction of this was localized to threonine residues. The quantitative analysis of the relation between PDB-stimulated force and the residues in MLC phosphorylated supports the concept that PDB stimulation results in activation of arterial smooth muscle cross bridges by MLC-phosphorylation-independent mechanisms.

  12. Elucidating the design principles of photosynthetic electron-transfer proteins by site-directed spin labeling EPR spectroscopy.

    Science.gov (United States)

    Ishara Silva, K; Jagannathan, Bharat; Golbeck, John H; Lakshmi, K V

    2016-05-01

    Site-directed spin labeling electron paramagnetic resonance (SDSL EPR) spectroscopy is a powerful tool to determine solvent accessibility, side-chain dynamics, and inter-spin distances at specific sites in biological macromolecules. This information provides important insights into the structure and dynamics of both natural and designed proteins and protein complexes. Here, we discuss the application of SDSL EPR spectroscopy in probing the charge-transfer cofactors in photosynthetic reaction centers (RC) such as photosystem I (PSI) and the bacterial reaction center (bRC). Photosynthetic RCs are large multi-subunit proteins (molecular weight≥300kDa) that perform light-driven charge transfer reactions in photosynthesis. These reactions are carried out by cofactors that are paramagnetic in one of their oxidation states. This renders the RCs unsuitable for conventional nuclear magnetic resonance spectroscopy investigations. However, the presence of native paramagnetic centers and the ability to covalently attach site-directed spin labels in RCs makes them ideally suited for the application of SDSL EPR spectroscopy. The paramagnetic centers serve as probes of conformational changes, dynamics of subunit assembly, and the relative motion of cofactors and peptide subunits. In this review, we describe novel applications of SDSL EPR spectroscopy for elucidating the effects of local structure and dynamics on the electron-transfer cofactors of photosynthetic RCs. Because SDSL EPR Spectroscopy is uniquely suited to provide dynamic information on protein motion, it is a particularly useful method in the engineering and analysis of designed electron transfer proteins and protein networks. This article is part of a Special Issue entitled Biodesign for Bioenergetics - the design and engineering of electronic transfer cofactors, proteins and protein networks, edited by Ronald L. Koder and J.L. Ross Anderson. PMID:26334844

  13. Transient structure formation in unfolded acyl-coenzyme A-binding protein observed by site-directed spin labelling

    DEFF Research Database (Denmark)

    Teilum, Kaare; Kragelund, Birthe B; Poulsen, Flemming M

    2002-01-01

    Paramagnetic relaxation has been used to monitor the formation of structure in the folding peptide chain of guanidinium chloride-denatured acyl-coenzyme A-binding protein. The spin label (1-oxyl-2,2,5,5-tetramethyl-3-pyrroline-3-methyl)methanesulfonate (MTSL) was covalently bound to a single...... affected in the native folded structure. It is suggested that the experiment is recording the formation of many discrete and transient structures in the polypeptide chain in the preface of protein folding. Analysis of secondary chemical shifts shows a high propensity for alpha-helix formation in the C...... state, and that these may be of importance to the initiation of protein folding....

  14. High-speed label-free detection by spinning-disk micro-interferometry

    OpenAIRE

    Varma, M. M.; Inerowicz, H. D.; Regnier, F. E.; Nolte, D. D.

    2004-01-01

    Spinning-disk interferometers are a new class of analytic sensors to detect immobilized biomolecules with high speed and high sensitivity. The disks are composed of a large number of surface-normal self-referencing interferometers, analogous to an optical CD, but operating on the principle of microdiffraction quadrature that achieves sensitive linear detection of bound molecules. The surface-normal structures have a small footprint of only 20 mum each, allowing potential integration to over a...

  15. Evaluation of spin labeled tartaric and galactaric diamides as potential MRI contrast enhancing agents

    International Nuclear Information System (INIS)

    Tartaric diamide (4) and Galactaric diamide (7) were synthesized for evaluation as potential contrast enhancing agents for MRI. These compounds (10 mM) elicited excellent spin-lattice (T1) and spin-spin (T2) relaxations of protons in water and plasma. Compound 7 possessed an insufficient solubility (10 mM) to be further considered for studies in animals models. In contrast, compound 4 exhibited a high solubility in water (220 mM) and human plasma. The reducibility of the compound 4 was assayed in vitro using rat kidney and liver homogenates. The rates for 4 were found to be between those for PCA (8) and TES (9), two extensively investigated mononitroxyls. The pharmacokinetics of 4 were investigated in vivo on blood and urine samples of dogs using EPR and HPLC methodologies. The metabolic pathway of 4 gives only one metabolite, the diamagnetic reduced form of 4. During the first 4 hours 50% of 4 is exerted. The clearance of 4 from blood is rapid and higher than that of TES. The non-ionic 4 might then be useful in medicinal research using animal models but it can not be adapted at present to clinical use because of instrumental time constraints

  16. Relaxation-based distance measurements between a nitroxide and a lanthanide spin label

    Science.gov (United States)

    Jäger, H.; Koch, A.; Maus, V.; Spiess, H. W.; Jeschke, G.

    2008-10-01

    Distance measurements by electron paramagnetic resonance techniques between labels attached to biomacromolecules provide structural information on systems that cannot be crystallized or are too large to be characterized by NMR methods. However, existing techniques are limited in their distance range and sensitivity. It is anticipated by theoretical considerations that these limits could be extended by measuring the enhancement of longitudinal relaxation of a nitroxide label due to a lanthanide complex label at cryogenic temperatures. The relaxivity of the dysprosium complex with the macrocyclic ligand DOTA can be determined without direct measurements of longitudinal relaxation rates of the lanthanide and without recourse to model compounds with well defined distance by analyzing the dependence of relaxation enhancement on either temperature or concentration in homogeneous glassy frozen solutions. Relaxivities determined by the two calibration techniques are in satisfying agreement with each other. Error sources for both techniques are examined. A distance of about 2.7 nm is measured in a model compound of the type nitroxide-spacer-lanthanide complex and is found in good agreement with the distance in a modeled structure. Theoretical considerations suggest that an increase of the upper distance limit requires measurements at lower fields and temperatures.

  17. Evaluation of glucose-linked nitroxide radicals for use as an in vivo spin-label probe.

    Science.gov (United States)

    Sato, Shingo; Yamaguchi, Masaki; Nagai, Akio; Onuma, Ryo; Saito, Misaki; Sugawara, Rina; Shinohara, Sayaka; Okabe, Eriko; Ito, Tomohiro; Ogata, Tateaki

    2014-04-24

    In vivo incorporation and reduction abilities of 4-carboxy-2,2,6,6-tetramethylpiperidine-1-oxyl (4-carboxy-TEMPO) (1), 3-carboxy-2,2,5,5-tetramethylpyrroline-1-oxyl (3-carboxy-dehydro-PROXYL, 3-carboxy-DPRO) (2), 4-hydroxy-TEMPO and 3-hydroxymethyl-DPRO O-β-D-glucosides (3 and 5), and newly designed forms of 6-O-(TEMPO-4-carbonyl and DPRO-3-carbonyl)-D-glucose (4 and 6) were evaluated using white radish sprouts. For each of these compounds, electron spin resonance (ESR) spectrometry was used to measure two effects: the rate of in vitro reduction via the addition of ascorbic acid; and, the rate of successful incorporation into radish sprouts for a reduction to the corresponding hydroxyl amine. DPRO-radicals 2, 5, and 6 were detected significantly more than TEMPO-radicals 1, 3, and 4 in vitro and in vivo for both experiments. Four glucose-linked nitroxide radicals were reduced faster than the glucose-non-linked ones in the in vitro experiment, but were nonetheless detected more each time in radish sprouts due to the absorbability. Glucose ester-linked radicals 4 and 6 were detected more than glycosides 3 and 5, which suggests that glucose ester-linked DPRO-radical 6 is the best for use as a spin-label probe that a plant will incorporate. PMID:24508871

  18. Orientation and Lipid-Peptide Interactions of Gramicidin A in Lipid Membranes: Polarized Attenuated Total Reflection Infrared Spectroscopy and Spin-Label Electron Spin Resonance

    Science.gov (United States)

    Kóta, Zoltán; Páli, Tibor; Marsh, Derek

    2004-01-01

    Gramicidin A was incorporated at a peptide/lipid ratio of 1:10 mol/mol in aligned bilayers of dimyristoyl phosphatidylcholine (DMPC), phosphatidylserine (DMPS), phosphatidylglycerol (DMPG), and phosphatidylethanolamine (DMPE), from trifluoroethanol. Orientations of the peptide and lipid chains were determined by polarized attenuated total reflection infrared spectroscopy. Lipid-peptide interactions with gramicidin A in DMPC bilayers were studied with different spin-labeled lipid species by using electron spin resonance spectroscopy. In DMPC membranes, the orientation of the lipid chains is comparable to that in the absence of peptide, in both gel and fluid phases. In gel-phase DMPC, the effective tilt of the peptide exceeds that of the lipid chains, but in the fluid phase both are similar. For gramicidin A in DMPS, DMPG, and DMPE, the degree of orientation of the peptide and lipid chains is less than in DMPC. In the fluid phase of DMPS, DMPG, and DMPE, gramicidin A is also less well oriented than are the lipid chains. In DMPE especially, gramicidin A is largely disordered. In DMPC membranes, three to four lipids per monomer experience direct motional restriction on interaction with gramicidin A. This is approximately half the number of lipids expected to contact the intramembranous perimeter of the gramicidin A monomer. A selectivity for certain negatively charged lipids is found in the interaction with gramicidin A in DMPC. These results are discussed in terms of the integration of gramicidin A channels in lipid bilayers, and of the interactions of lipids with integral membrane proteins. PMID:14990479

  19. Local motion and conformational changes in the cuticle of Clivia miniata Regel : A microfluorescence and spin-label study.

    Science.gov (United States)

    Wunderlich, A P; Gaub, H; Marsh, D; Sackmann, E

    1990-07-01

    The temperature dependence of the local diffusion of fluorescent molecular probes of various polarities (alkane, long-chain fatty acid, short-chain alcohol and fatty acid), all labelled with 7-nitrobenz-2-oxa-1,3-diazol-4-yl in the cuticle of Clivia miniata Regel was studied by the technique of fluorescence recovery after photobleaching. The technique yields the coefficient of diffusion, D, in the plane of the cuticle over distances of some 10 μm and the fraction, R, of mobile reporter molecules. The inner (more hydrophilic) and the outer (more hydrophobic) faces of the cuticle were studied separately by appropriate incubation. The value of D was found to depend sensitively on the polarity of the probe, the temperature and the position within the cuticle (outer hydrophobic or inner hydrophilic side). Depending on the type of probe, D increased (in the case of the alkane) or decreased (in the case of the alcohol) after removal of the (monomeric) waxes. The electron-spin-resonance (ESR) spectra of incorporated spin-labelled fatty-acid probes measured in the intact cuticle contained a major component similar to the spectrum recorded from the polymerized matrix from which waxes had been extracted, and a second component similar to the spectrum from the monomeric waxes. At low temperatures, the ESR spectra from labels at two different chain positions corresponded to chain motion which was slow on the ESR timescale. At high temperatures, the spectral component from the monomeric waxes indicated chain motions in the motional narrowing regime which were of an essentially isotropic nature.No evidence was found for a liquid-crystalline lipid phase such as found for the polar lipids in cell membranes, nor was there evidence for a sharp, thermotropic, lipid-phase transition either in the cuticle or in the waxes. Experiments with oriented samples did not demonstrate the presence of large domains with a uniform orientation of the lipid chains relative to the cuticular layers

  20. Structural Changes of a Doubly Spin-Labeled Chemically Driven Molecular Shuttle Probed by PELDOR Spectroscopy.

    Science.gov (United States)

    Franchi, Paola; Bleve, Valentina; Mezzina, Elisabetta; Schäfer, Christian; Ragazzon, Giulio; Albertini, Marco; Carbonera, Donatella; Credi, Alberto; Di Valentin, Marilena; Lucarini, Marco

    2016-06-20

    Gaining detailed information on the structural rearrangements associated with stimuli-induced molecular movements is of utmost importance for understanding the operation of molecular machines. Pulsed electron-electron double resonance (PELDOR) was employed to monitor the geometrical changes arising upon chemical switching of a [2]rotaxane that behaves as an acid-base-controlled molecular shuttle. To this aim, the rotaxane was endowed with stable nitroxide radical units in both the ring and axle components. The combination of PELDOR data and molecular dynamic calculations indicates that in the investigated rotaxane, the ring displacement along the axle, caused by the addition of a base, does not alter significantly the distance between the nitroxide labels, but it is accompanied by a profound change in the geometry adopted by the macrocycle. PMID:27123774

  1. The effects of general anesthetics on ESR spectra of spin labels in phosphatidylcholine vesicles containing purified Na,K-ATPase or microsomal protein

    Energy Technology Data Exchange (ETDEWEB)

    Shibuya, Makiko, E-mail: shibu@den.hokudai.ac.jp [Department of Dental Anesthesiology, Graduate School of Dental Medicine, Hokkaido University (Japan); Hiraoki, Toshifumi [Division of Applied Physics, Graduate School of Engineering, Hokkaido University (Japan); Kimura, Kunie; Fukushima, Kazuaki [Department of Dental Anesthesiology, Graduate School of Dental Medicine, Hokkaido University (Japan); Suzuki, Kuniaki [Department of Molecular Cell Pharmacology, Graduate School of Dental Medicine, Hokkaido University (Japan)

    2012-12-01

    Highlights: Black-Right-Pointing-Pointer We studied the effects of general anesthetics on liposome using ESR spectra. Black-Right-Pointing-Pointer Two spin labels, 5-DSA and 16-DSA, were located in different position in liposome. Black-Right-Pointing-Pointer Anesthetics did not change the environment around the spin labels in the liposome. Black-Right-Pointing-Pointer Anesthetics remained on the surface of the lipid bilayer of liposome. Black-Right-Pointing-Pointer Proteins in the liposome did not change the effects of anesthetics on liposome. - Abstract: We investigated the effects of general anesthetics on liposome containing spin labels, 5-doxyl stearic acid (5-DSA) and 16-doxyl stearic acid (16-DSA), and purified Na,K-ATPase or membrane protein of microsome using an electron spin resonance (ESR) spectroscopy. The spectra of 16-DSA in liposomes with both proteins showed three sharp signals compared with 5-DSA. The difference in the order parameter S value of 5-DSA and 16-DSA suggested that the nitroxide radical location of 5-DSA and 16-DSA were different in the membrane bilayer. The results were almost the same as those obtained in liposomes without proteins. The addition of sevoflurane, isoflurane, halothane, ether, ethanol and propofol increased the intensity of the signals, but the clinical concentrations of anesthetics did not significantly alter the S and {tau} values, which are indices of the fluidity of the membrane. These results suggest that anesthetics remain on the surface of the lipid bilayer and do not act on both the inside hydrophobic area and the relatively hydrophilic area near the surface. These results and others also suggest that the existence of Na,K-ATPase and microsomal proteins did not affect the environment around the spin labels in the liposome and the effects of anesthetics on liposome as a model membrane.

  2. The effects of general anesthetics on ESR spectra of spin labels in phosphatidylcholine vesicles containing purified Na,K-ATPase or microsomal protein

    International Nuclear Information System (INIS)

    Highlights: ► We studied the effects of general anesthetics on liposome using ESR spectra. ► Two spin labels, 5-DSA and 16-DSA, were located in different position in liposome. ► Anesthetics did not change the environment around the spin labels in the liposome. ► Anesthetics remained on the surface of the lipid bilayer of liposome. ► Proteins in the liposome did not change the effects of anesthetics on liposome. - Abstract: We investigated the effects of general anesthetics on liposome containing spin labels, 5-doxyl stearic acid (5-DSA) and 16-doxyl stearic acid (16-DSA), and purified Na,K-ATPase or membrane protein of microsome using an electron spin resonance (ESR) spectroscopy. The spectra of 16-DSA in liposomes with both proteins showed three sharp signals compared with 5-DSA. The difference in the order parameter S value of 5-DSA and 16-DSA suggested that the nitroxide radical location of 5-DSA and 16-DSA were different in the membrane bilayer. The results were almost the same as those obtained in liposomes without proteins. The addition of sevoflurane, isoflurane, halothane, ether, ethanol and propofol increased the intensity of the signals, but the clinical concentrations of anesthetics did not significantly alter the S and τ values, which are indices of the fluidity of the membrane. These results suggest that anesthetics remain on the surface of the lipid bilayer and do not act on both the inside hydrophobic area and the relatively hydrophilic area near the surface. These results and others also suggest that the existence of Na,K-ATPase and microsomal proteins did not affect the environment around the spin labels in the liposome and the effects of anesthetics on liposome as a model membrane.

  3. Imaging characteristics of two-dimensional spin echo T1-weighted image in carotid artery plaque

    International Nuclear Information System (INIS)

    Recently, T1 weighted image (T1WI) has proven to be useful for diagnosing carotid plaque. This time, the image parameter of two-dimensional spin echo (2D SE) T1WI was examined. Phantoms that imitated muscle and carotid plaque were made. Signal noise ratio (SNR) and the contrast of phantoms were examined when the flip angle (FA) of radio frequency (RF) pulse, repetition time (TR), and echo train length (ETL) was changed. A visual evaluation was done in a clinical case. Both SE and fast spin echo (FSE) SNR improved according to the extension of TR, and the contrast decreased. Moreover, the contrast improved when there was a lot of ETL and the FA of RF pulse. It is thought that this is because SNR and the contrast depend on the interrelation of TR, T1 value, and the FA of RF pulse. When the FA of RF pulse was set to 70 degrees and the TR was set to 400 ms resulting from the phantom experiment, clinical cases obtained great results. This examination confirmed the utility of 2D SE in carotid plaque inspection. (author)

  4. In vivo tracking of human adipose-derived stem cells labeled with ferumoxytol in rats with middle cerebral artery occlusion by magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Yan Yin

    2015-01-01

    Full Text Available Ferumoxytol, an iron replacement product, is a new type of superparamagnetic iron oxide approved by the US Food and Drug Administration. Herein, we assessed the feasibility of tracking transplanted human adipose-derived stem cells labeled with ferumoxytol in middle cerebral artery occlusion-injured rats by 3.0 T MRI in vivo. 1 × 10 4 human adipose-derived stem cells labeled with ferumoxytol-heparin-protamine were transplanted into the brains of rats with middle cerebral artery occlusion. Neurologic impairment was scored at 1, 7, 14, and 28 days after transplantation. T2-weighted imaging and enhanced susceptibility-weighted angiography were used to observe transplanted cells. Results of imaging tests were compared with results of Prussian blue staining. The modified neurologic impairment scores were significantly lower in rats transplanted with cells at all time points except 1 day post-transplantation compared with rats without transplantation. Regions with hypointense signals on T2-weighted and enhanced susceptibility-weighted angiography images corresponded with areas stained by Prussian blue, suggesting the presence of superparamagnetic iron oxide particles within the engrafted cells. Enhanced susceptibility-weighted angiography image exhibited better sensitivity and contrast in tracing ferumoxytol-heparin-protamine-labeled human adipose-derived stem cells compared with T2-weighted imaging in routine MRI.

  5. QM/MD studies of the dynamics of the MTSL spin label in Aurora-A kinase protein activation loop

    CERN Document Server

    Concilio, Maria Grazia; Bayliss, Richard; Burgess, Selena

    2015-01-01

    Molecular dynamics(MD)simulations using a graphics processing unit (GPU) has been employed in order to determine the conformational space of the methane-thiosulfonate spin label (MTSL) attached to the activation loop of the Aurora-A kinase protein and compared with quantum mechanical (QM) methods rooted on density functional theory (DFT). MD provided a wealth of information about interactions between the MTSL and the residues of the protein and on the different motional contributions to the overall dynamics of the MTSL. Data obtained from MD were seen to be in good agreement with those obtained from QM but the dynamics of the system revealed more interactions than those observed from QM methods. A strong correlation between the tumbling of the protein and the transitions of the X4 and X5 dihedral angles of the MTSL, was observed with a consequent effect also the distribution of the nitroxide(NO)group in the space. Theoretical EPR spectra calculated from opportunely selected MD frames showing interactions betw...

  6. Kinetics of rapid covalent bond formation of aniline with humic acid: ESR investigations with nitroxide spin labels

    Science.gov (United States)

    Glinka, Kevin; Matthies, Michael; Theiling, Marius; Hideg, Kalman; Steinhoff, Heinz-Jürgen

    2016-04-01

    Sulfonamide antibiotics used in livestock farming are distributed to farmland by application of slurry as fertilizer. Previous work suggests rapid covalent binding of the aniline moiety to humic acids found in soil. In the current work, kinetics of this binding were measured in X-band EPR spectroscopy by incubating Leonardite humic acid (LHA) with a paramagnetic aniline spin label (anilino-NO (2,5,5-Trimethyl-2-(3-aminophenyl)pyrrolidin-1-oxyl)). Binding was detected by a pronounced broadening of the spectral lines after incubation of LHA with anilino-NO. The time evolution of the amplitude of this feature was used for determining the reaction kinetics. Single- and double-exponential models were fitted to the data obtained for modelling one or two first-order reactions. Reaction rates of 0.16 min-1 and 0.012 min-1, were found respectively. Addition of laccase peroxidase did not change the kinetics but significantly enhanced the reacting fraction of anilino-NO. This EPR-based method provides a technically simple and effective method for following rapid binding processes of a xenobiotic substance to humic acids.

  7. Electron paramagnetic resonance (EPR) study of spin-labeled camptothecin derivatives: a different look of the ternary complex.

    Science.gov (United States)

    Ricci, Antonio; Marinello, Jessica; Bortolus, Marco; Sánchez, Albert; Grandas, Anna; Pedroso, Enrique; Pommier, Yves; Capranico, Giovanni; Maniero, Anna Lisa; Zagotto, Giuseppe

    2011-02-24

    Camptothecin (CPT) derivatives are clinically effective poisons of DNA topoisomerase I (Top1) able to form a ternary complex with the Top1-DNA complex. The aim of this investigation was to examine the dynamic aspects of the ternary complex formation by means of site-directed spin labeling electron paramagnetic resonance (SDSL-EPR). Two semisynthetic CPT derivatives bearing the paramagnetic moiety were synthesized, and their biological activity was tested. A 22-mer DNA oligonucleotide sequence with high affinity cleavage site for Top1 was also synthesized. EPR experiments were carried out on modified CPT in the presence of DNA, of Top1, or of both. In the last case, a slow motion component in the EPR signal appeared, indicating the formation of the ternary complex. Deconvolution of the EPR spectrum allowed to obtain the relative drug amounts in the complex. It was also possible to demonstrate that the residence time of CPT "trapped" in the ternary complex is longer than hundreds of microseconds. PMID:21254781

  8. Toward increased concentration sensitivity for continuous wave EPR investigations of spin-labeled biological macromolecules at high fields

    Science.gov (United States)

    Song, Likai; Liu, Zhanglong; Kaur, Pavanjeet; Esquiaqui, Jackie M.; Hunter, Robert I.; Hill, Stephen; Smith, Graham M.; Fanucci, Gail E.

    2016-04-01

    High-field, high-frequency electron paramagnetic resonance (EPR) spectroscopy at W-(∼94 GHz) and D-band (∼140 GHz) is important for investigating the conformational dynamics of flexible biological macromolecules because this frequency range has increased spectral sensitivity to nitroxide motion over the 100 ps to 2 ns regime. However, low concentration sensitivity remains a roadblock for studying aqueous samples at high magnetic fields. Here, we examine the sensitivity of a non-resonant thin-layer cylindrical sample holder, coupled to a quasi-optical induction-mode W-band EPR spectrometer (HiPER), for continuous wave (CW) EPR analyses of: (i) the aqueous nitroxide standard, TEMPO; (ii) the unstructured to α-helical transition of a model IDP protein; and (iii) the base-stacking transition in a kink-turn motif of a large 232 nt RNA. For sample volumes of ∼50 μL, concentration sensitivities of 2-20 μM were achieved, representing a ∼10-fold enhancement compared to a cylindrical TE011 resonator on a commercial Bruker W-band spectrometer. These results therefore highlight the sensitivity of the thin-layer sample holders employed in HiPER for spin-labeling studies of biological macromolecules at high fields, where applications can extend to other systems that are facilitated by the modest sample volumes and ease of sample loading and geometry.

  9. Electron paramagnetic resonance spin label titration: a novel method to investigate random and site-specific immobilization of enzymes onto polymeric membranes with different properties

    International Nuclear Information System (INIS)

    The immobilization of biological molecules onto polymeric membranes to produce biofunctional membranes is used for selective catalysis, separation, analysis, and artificial organs. Normally, random immobilization of enzymes onto polymeric membranes leads to dramatic reduction in activity due to chemical reactions involved in enzyme immobilization, multiple-point binding, etc., and the extent of activity reduction is a function of membrane hydrophilicity (e.g. activity in cellulosic membrane >> polysulfone membrane). We have used molecular biology to effect site-specific immobilization of enzymes in a manner that orients the active site away from the polymeric membrane surface, thus resulting in higher enzyme activity that approaches that in solution and in increased stability of the enzyme relative to the enzyme in solution. A prediction of this site-specific method of enzyme immobilization, which in this study with subtilisin and organophosphorus hydrolase consists of a fusion tag genetically added to these enzymes and subsequent immobilization via the anti-tag antibody and membrane-bound protein A, is that the active site conformation will more closely resemble that of the enzyme in solution than is the case for random immobilization. This hypothesis was confirmed using a new electron paramagnetic resonance (EPR) spin label active site titration method that determines the amount of spin label bound to the active site of the immobilized enzyme. This value nearly perfectly matched the enzyme activity, and the results suggested: (a) a spectroscopic method for measuring activity and thus the extent of active enzyme immobilization in membrane, which may have advantages in cases where optical methods can not be used due to light scattering interference; (b) higher spin label incorporation (and hence activity) in enzymes that had been site-specifically immobilized versus random immobilization; (c) higher spin label incorporation in enzymes immobilized onto hydrophilic

  10. Electron paramagnetic resonance spin label titration: a novel method to investigate random and site-specific immobilization of enzymes onto polymeric membranes with different properties

    Energy Technology Data Exchange (ETDEWEB)

    Butterfield, D. Allan; Colvin, Joshua; Liu Jiangling; Wang Jianquan; Bachas, Leonidas; Bhattacharrya, Dibakar

    2002-10-11

    The immobilization of biological molecules onto polymeric membranes to produce biofunctional membranes is used for selective catalysis, separation, analysis, and artificial organs. Normally, random immobilization of enzymes onto polymeric membranes leads to dramatic reduction in activity due to chemical reactions involved in enzyme immobilization, multiple-point binding, etc., and the extent of activity reduction is a function of membrane hydrophilicity (e.g. activity in cellulosic membrane >> polysulfone membrane). We have used molecular biology to effect site-specific immobilization of enzymes in a manner that orients the active site away from the polymeric membrane surface, thus resulting in higher enzyme activity that approaches that in solution and in increased stability of the enzyme relative to the enzyme in solution. A prediction of this site-specific method of enzyme immobilization, which in this study with subtilisin and organophosphorus hydrolase consists of a fusion tag genetically added to these enzymes and subsequent immobilization via the anti-tag antibody and membrane-bound protein A, is that the active site conformation will more closely resemble that of the enzyme in solution than is the case for random immobilization. This hypothesis was confirmed using a new electron paramagnetic resonance (EPR) spin label active site titration method that determines the amount of spin label bound to the active site of the immobilized enzyme. This value nearly perfectly matched the enzyme activity, and the results suggested: (a) a spectroscopic method for measuring activity and thus the extent of active enzyme immobilization in membrane, which may have advantages in cases where optical methods can not be used due to light scattering interference; (b) higher spin label incorporation (and hence activity) in enzymes that had been site-specifically immobilized versus random immobilization; (c) higher spin label incorporation in enzymes immobilized onto hydrophilic

  11. Mapping molecular flexibility of spin labeled proteins on the nanosecond and longer time scales via CW lineshape analysis and osmolyte-perturbation EPR

    OpenAIRE

    López, Carlos Javier

    2012-01-01

    Proteins in solution exhibit structural fluctuations on a wide range of characteristic time scales, from fast backbone motions in the picosecond to nanosecond range to slow conformational exchange in the microsecond to millisecond time domain. These motions can play important roles in function, thus elucidation of molecular mechanisms underlying function requires experimental techniques capable of measuring motions on these time scales. Site directed spin labeling and EPR spectroscopy (SDSL-...

  12. Quantitation of platelet loss with indium-111 labeled platelets in a hollow-fiber membrane oxygenator and arterial filter during extracorporeal circulation in a pig model

    International Nuclear Information System (INIS)

    Platelet consumption in a hollow-fiber membrane oxygenator (HFMO) and arterial filter (AF) during cardiopulmonary bypass (CPB) was quantified in five pigs using Indium-111 labeled autologous platelets. Platelet labeling was performed 20-24 hours before CPB. After general endotracheal anesthesia, the pigs were systemically heparinized and were placed on CPB via a median sternotomy. After 3 hours of CPB, radioactivity was quantified with a gamma camera and an ionization chamber. The percent of injected dose (mean ± SD) was 0.79 +/- 0.45 in the HFMO, 2.52 ± 0.93 in AF, 4.3 ± 1.2 in blood loss during CPB. Platelet consumption in HFMO during CPB was lower than in bubble oxygenators (19%) or silicone membrane oxygenators (12%) as observed in previous studies

  13. Interaction of Spin-Labeled Inhibitors of the Vacuolar H+-ATPase with the Transmembrane Vo-Sector

    Science.gov (United States)

    Dixon, Neil; Páli, Tibor; Kee, Terence P.; Ball, Stephen; Harrison, Michael A.; Findlay, John B. C.; Nyman, Jonas; Väänänen, Kalervo; Finbow, Malcolm E.; Marsh, Derek

    2008-01-01

    The osteoclast variant of the vacuolar H+-ATPase (V-ATPase) is a potential therapeutic target for combating the excessive bone resorption that is involved in osteoporosis. The most potent in a series of synthetic inhibitors based on 5-(5,6-dichloro-2-indolyl)-2-methoxy-2,4-pentadienamide (INDOL0) has demonstrated specificity for the osteoclast enzyme, over other V-ATPases. Interaction of two nitroxide spin-labeled derivatives (INDOL6 and INDOL5) with the V-ATPase is studied here by using the transport-active 16-kDa proteolipid analog of subunit c from the hepatopancreas of Nephrops norvegicus, in conjunction with electron paramagnetic resonance (EPR) spectroscopy. Analogous experiments are also performed with vacuolar membranes from Saccharomyces cerevisiae, in which subunit c of the V-ATPase is replaced functionally by the Nephrops 16-kDa proteolipid. The INDOL5 derivative is designed to optimize detection of interaction with the V-ATPase by EPR. In membranous preparations of the Nephrops 16-kDa proteolipid, the EPR spectra of INDOL5 contain a motionally restricted component that arises from direct association of the indolyl inhibitor with the transmembrane domain of the proteolipid subunit c. A similar, but considerably smaller, motionally restricted population is detected in the EPR spectra of the INDOL6 derivative in vacuolar membranes, in addition to the larger population from INDOL6 in the fluid bilayer regions of the membrane. The potent classical V-ATPase inhibitor concanamycin A at high concentrations induces motional restriction of INDOL5, which masks the spectral effects of displacement at lower concentrations of concanamycin A. The INDOL6 derivative, which is closest to the parent INDOL0 inhibitor, displays limited subtype specificity for the osteoclast V-ATPase, with an IC50 in the 10-nanomolar range. PMID:17872954

  14. Contribution of tryptophan residues to the combining site of a monoclonal anti dinitrophenyl spin-label antibody

    International Nuclear Information System (INIS)

    Two Fab fragments of the monoclonal anti dinitrophenyl (DNP) spin-label antibody AN02 were prepared by recombination of specifically deuterated heavy and light chains. In the recombinant H(I)L(II) all the tyrosines and phenylalanines were perdeuterated as were the tryptophan residues of the heavy chain. In the recombinant H(II)L(I) all the tyrosines and phenylalanines were perdeuterated as were the tryptophan residues of the light chain. Saturation of three resonances of H(I)L(II), assigned to tryptophan protons of the light chain, resulted in magnetization transfer to the aromatic proton at position 6 of the DNP ring and to the CH2 protons of the glycines linked to the DNP in a diamagnetic hapten (DNP-DG). Saturation of three resonances of H(II)L(I) assigned to tryptophan protons of the heavy chain resulted in magnetization transfer to the CH2 protons of the glycines in DNP-DG. From the dependence of the magnetization transfer on the irradiation time, the cross relaxation rates between the involved protons were estimated. The inferred distances between these protons of the hapten and certain tryptophan protons are 3-4 A. It is concluded that in the combining site of AN02 there is one tryptophan from the light chain and one tryptophan from the heavy chain that are very near the hapten. When all tyrosines and phenylalanines were perdeuterated and all tryptophan aromatic protons were deuterated except for the protons at positions 2 and 5, titration of the Fab fragments with variable amounts of paramagnetic hapten showed that one proton from the light chain tryptophan is near (less than 7 A) the unpaired electron and that three other protons are significantly closer than 15 A

  15. Radioimmunoscintigraphy of experimental internal carotid arterial thrombi in dogs with 99mTc-labelled monoclonal anti-activated platelet antibody SZ-51

    International Nuclear Information System (INIS)

    The capacity of McAbSZ-51, which is specific for an α-granule membrane protein (GMP-140) expressed on the surface of activated platelets, to bind to the grafted human thrombus in rabbits was studied. The feasibility of imaging thrombus with 99mTc-labelled McAbSZ-51 in the internal carotid artery of dog was also explored. The results showed that McAbSZ-51 could bind to the grafted human thrombus in rabbits. The thrombus in internal carotid artery was clearly discerned at 2 to 6 h after injection of 99mTc-SZ-51, with the optimal imaging time at 2 to 4 h after injection. The radioactivity ratio of thrombus to blood was 6.03 +- 1.09 at 6 to 8 h after injection. It is thus concluded that by using the 99mTc-labelled McAbSZ-51, the early and specific detection of thrombi formed in vivo was fairly possible and feasible. (3 figs., 1 tab.)

  16. Usefulness of Tc-99m HMPAO-labeled WBC heart scan to predict impaired ventricular function and coronary artery dilation in children with Kawasaki disease.

    Science.gov (United States)

    Hsu, Hsiu-Bao; Fu, Yun-Ching; Tsai, Shih-Chuan; Yen, Ruoh-Fang; Hwang, Betau

    2003-11-01

    Forty-nine children with Kawasaki disease were included in this study. Based on the severity of carditis as determined by Tc-99m HMPAO-labeled WBC heart scan, the children were separated into two groups. Group A (n=24) had significant carditis and group B (n=25) did not have significant carditis. The left and right ventricular ejection fractions (LVEF and RVEF) were evaluated by equilibrium multigated blood pooling ventriculography. Diameters of the left and right coronary arteries (LCA and RCA) were measured by two-dimensional echocardiography. The results showed that group A had lower LVEF and RVEF, but larger diameters of the LCA and RCA than those of group B patients. The sensitivity of significant carditis to predict left ventricular dysfunction, right ventricular dysfunction, LCA dilation and RCA dilation was 88.9, 70.6, 75, and 71.4%, respectively; the specificities were 100, 100, 100, and 67.9%, respectively. Our findings suggest that significant carditis determined by Tc-99m HMPAO-labeled WBC heart scan can accurately predict impaired ventricular function and coronary artery dilation. PMID:14602219

  17. TEMPO-derived spin labels linked to the nucleobases adenine and cytosine for probing local structural perturbations in DNA by EPR spectroscopy

    Directory of Open Access Journals (Sweden)

    Dnyaneshwar B. Gophane

    2015-02-01

    Full Text Available Three 2´-deoxynucleosides containing semi-flexible spin labels, namely TA, UA and UC, were prepared and incorporated into deoxyoligonucleotides using the phosphoramidite method. All three nucleosides contain 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO connected to the exocyclic amino group; TA directly and UA as well as UC through a urea linkage. TA and UC showed a minor destabilization of a DNA duplex, as registered by a small decrease in the melting temperature, while UA destabilized the duplex by more than 10 °C. Circular dichroism (CD measurements indicated that all three labels were accommodated in B-DNA duplex. The mobility of the spin label TA varied with different base-pairing partners in duplex DNA, with the TA•T pair being the least mobile. Furthermore, TA showed decreased mobility under acidic conditions for the sequences TA•C and TA•G, to the extent that the EPR spectrum of the latter became nearly superimposable to that of TA•T. The reduced mobility of the TA•C and TA•G mismatches at pH 5 is consistent with the formation of TAH+•C and TAH+•G, in which protonation of N1 of A allows the formation of an additional hydrogen bond to N3 of C and N7 of G, respectively, with G in a syn-conformation. The urea-based spin labels UA and UC were more mobile than TA, but still showed a minor variation in their EPR spectra when paired with A, G, C or T in a DNA duplex. UA and UC had similar mobility order for the different base pairs, with the lowest mobility when paired with C and the highest when paired with T.

  18. Morpholino spin-labeling for base-pair sequencing of a 3'-terminal RNA stem by proton homonuclear Overhauser enhancements: yeast ribosomal 5S RNA

    International Nuclear Information System (INIS)

    Base-pair sequences for 5S and 5.8S RNAs are not readily extracted from proton homonuclear nuclear Overhauser enhancement (NOE) connectivity experiments alone, due to extensive peak overlap in the downfield (11-15 ppm) proton NMR spectrum. In this paper, we introduce a new method for base-pair proton peak assignment for ribosomal RNAs, based upon the distance-dependent broadening of the resonances of base-pair protons spatially proximal to a paramagnetic group. Introduction of a nitroxide spin-label covalently attached to the 3'-terminal ribose provides an unequivocal starting point for base-pair hydrogen-bond proton NMR assignment. Subsequent NOE connectivities then establish the base-pair sequence for the terminal stem of a 5S RNA. Periodate oxidation of yeast 5S RNA, followed by reaction with 4-amino-2,2,6,6-tetramethylpiperidinyl-1-oxy (TEMPO-NH2) and sodium borohydride reduction, produces yeast 5S RNA specifically labeled with a paramagnetic nitroxide group at the 3'-terminal ribose. Comparison of the 500-MHz 1H NMR spectra of native and 3'-terminal spin-labeled yeast 5S RNA serves to identify the terminal base pair (G1 . C120) and its adjacent base pair (G2 . U119) on the basis of their proximity to the 3'-terminal spin-label. From that starting point, we have then identified (G . C, A . U, or G . U) and sequenced eight of the nine base pairs in the terminal helix via primary and secondary NOE's

  19. Radiation dose estimates for the arterial injection of Tc-99m labeled HSA microspheres and macroaggregated particles

    International Nuclear Information System (INIS)

    Particles of human serum albumin, such as macroaggregated albumin or microspheres, have been injected intra-arterially for the following indications: to examine tumor perfusion prior to and during chemotherapy, to examine coronary artery perfusion, and in the diagnosis of peripheral vascular disease. The region of distribution of the particles is localized according to the artery selected for injection. The radiation dose is affected by the distribution of the radioactivity in time and space and the physical parameters of the radionuclide. In addition, the radiation dose estimate takes into account the mass and geometry of the perfused volume. In certain cases, there is a significant amount of shunting of the injected particles; the radiation dose conferred by the shunted particles is to the lung tissue. 25 references, 6 tables

  20. Optimal Blood Suppression inversion time based on breathing rates and heart rates to improve renal artery visibility in spatial labeling with multiple inversion pulses: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Yi Gang; Li, Fang; Long, Xue Ying; Liu, Hui; Wang, Xiao Yi; Liu, Jin Kang; Li, Wen Zheng [Dept. of Radiology, Xiangya Hospital, Central South University, Changsha (China); Shen, Hao [GE Healthcare, Waukesha (United States)

    2016-02-15

    To determine whether an optimal blood suppression inversion time (BSP TI) can boost arterial visibility and whether the optimal BSP TI is related to breathing rate (BR) and heart rate (HR) for hypertension subjects in spatial labeling with multiple inversion pulses (SLEEK). This prospective study included 10 volunteers and 93 consecutive hypertension patients who had undergone SLEEK at 1.5T MRI system. Firstly, suitable BSP TIs for displaying clearly renal artery were determined in 10 volunteers. Secondly, non-contrast enhanced magnetic resonance angiography with the suitable BSP TIs were performed on those hypertension patients. Then, renal artery was evaluated and an optimal BSP TI to increase arterial visibility was determined for each patient. Patients' BRs and HRs were recorded and their relationships with the optimal BSP TI were analyzed. The optimal BSP TI was negatively correlated with BR (r1 = -0.536, P1 < 0.001; and r2 = -0.535, P2 < 0.001) and HR (r1 = -0.432, P1 = 0.001; and r2 = -0.419, P2 = 0.001) for 2 readers (κ = 0.93). For improving renal arterial visibility, BSP TI = 800 ms could be applied as the optimal BSP TI when the 95% confidence interval were 17-19/min (BR1) and 74-82 bpm (HR1) for reader#1 and 17-19/min (BR2) and 74-83 bpm (HR2) for reader#2; BSP TI = 1100 ms while 14-15/min (BR1, 2) and 71-76 bpm (HR1, 2) for both readers; and BSP TI = 1400 ms when 13-16/min (BR1) and 63-68 bpm (HR1) for reader#1 and 14-15/min (BR2) and 64-70 bpm (HR2) for reader#2. In SLEEK, BSP TI is affected by patients' BRs and HRs. Adopting the optimal BSP TI based on BR and HR can improve the renal arterial visibility and consequently the working efficiency.

  1. An a contrario approach for the detection of patient-specific brain perfusion abnormalities with arterial spin labelling.

    Science.gov (United States)

    Maumet, Camille; Maurel, Pierre; Ferré, Jean-Christophe; Barillot, Christian

    2016-07-01

    In this paper, we introduce a new locally multivariate procedure to quantitatively extract voxel-wise patterns of abnormal perfusion in individual patients. This a contrario approach uses a multivariate metric from the computer vision community that is suitable to detect abnormalities even in the presence of closeby hypo- and hyper-perfusions. This method takes into account local information without applying Gaussian smoothing to the data. Furthermore, to improve on the standard a contrario approach, which assumes white noise, we introduce an updated a contrario approach that takes into account the spatial coherency of the noise in the probability estimation. Validation is undertaken on a dataset of 25 patients diagnosed with brain tumours and 61 healthy volunteers. We show how the a contrario approach outperforms the massively univariate general linear model usually employed for this type of analysis. PMID:27039702

  2. Assessment of Alzheimer's disease risk with structural and functional magnetic resonance imaging : an arterial spin labeling study

    OpenAIRE

    Bangen, Katherine J.

    2010-01-01

    BACKGROUND : There are several risk factors for the development of Alzheimer's disease (AD) including the apolipoprotein E (APOE) e4 allele, an important susceptibility gene for AD, and mild cognitive impairment (MCI). The literature to date generally indicates that nondemented older adults at risk for AD by virtue of their cognitive (i.e., MCI) and/or genetic (i.e., APOE) status demonstrate reduced medial temporal lobe (MTL) volumes and divergent brain response patterns during memory encodin...

  3. SU-E-I-65: Estimation of Tagging Efficiency in Pseudo-Continuous Arterial Spin Labeling (pCASL) MRI

    Energy Technology Data Exchange (ETDEWEB)

    Jen, M [Chang Gung University, Taoyuan City, Taiwan (China); Yan, F; Tseng, Y; Chen, C [Taipei Medical University - Shuang Ho Hospital, Ministry of Health and Welf, New Taipei City, Taiwan (China); Lin, C [GE Healthcare, Taiwan (China); GE Healthcare China, Beijing (China); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: pCASL was recommended as a potent approach for absolute cerebral blood flow (CBF) quantification in clinical practice. However, uncertainties of tagging efficiency in pCASL remain an issue. This study aimed to estimate tagging efficiency by using short quantitative pulsed ASL scan (FAIR-QUIPSSII) and compare resultant CBF values with those calibrated by using 2D Phase Contrast (PC) MRI. Methods: Fourteen normal volunteers participated in this study. All images, including whole brain (WB) pCASL, WB FAIR-QUIPSSII and single-slice 2D PC, were collected on a 3T clinical MRI scanner with a 8-channel head coil. DeltaM map was calculated by averaging the subtraction of tag/control pairs in pCASL and FAIR-QUIPSSII images and used for CBF calculation. Tagging efficiency was then calculated by the ratio of mean gray matter CBF obtained from pCASL and FAIR-QUIPSSII. For comparison, tagging efficiency was also estimated with 2D PC, a previously established method, by contrast WB CBF in pCASL and 2D PC. Feasibility of estimation from a short FAIR-QUIPSSII scan was evaluated by number of averages required for obtaining a stable deltaM value. Setting deltaM calculated by maximum number of averaging (50 pairs) as reference, stable results were defined within ±10% variation. Results: Tagging efficiencies obtained by 2D PC MRI (0.732±0.092) were significantly lower than which obtained by FAIRQUIPPSSII (0.846±0.097) (P<0.05). Feasibility results revealed that four pairs of images in FAIR-QUIPPSSII scan were sufficient to obtain a robust calibration of less than 10% differences from using 50 pairs. Conclusion: This study found that reliable estimation of tagging efficiency could be obtained by a few pairs of FAIR-QUIPSSII images, which suggested that calibration scan in a short duration (within 30s) was feasible. Considering recent reports concerning variability of PC MRI-based calibration, this study proposed an effective alternative for CBF quantification with pCASL.

  4. An a contrario approach for the detection of patient-specific brain perfusion abnormalities with arterial spin labelling

    OpenAIRE

    Maumet, Camille; Maurel, Pierre; Ferré, Jean-Christophe; Barillot, Christian

    2016-01-01

    International audience In this paper, we introduce a new locally multivariate procedure to quantitatively extract voxel-wise patterns of abnormal perfusion in individual patients. This a contrario approach uses a multivariate metric from the computer vision community that is suitable to detect abnormalities even in the presence of closeby hypo- and hyper-perfusions. This method takes into account local information without applying Gaussian smoothing to the data. Furthermore, to improve on ...

  5. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier;

    2010-01-01

    metabolism. So far, ASL has been restricted mostly to specialist centers due to a generally low SNR of the method and potential issues with user-dependent analysis needed to obtain quantitative measurement of cerebral blood flow (CBF). Here, we evaluated a particular implementation of ASL (called...... total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing...

  6. The effect of black tea and caffeine on regional cerebral blood flow measured with arterial spin labeling

    OpenAIRE

    Vidyasagar, Rishma; Greyling, Arno; Draijer, Richard; Corfield, Douglas R; Parkes, Laura M.

    2013-01-01

    Black tea consumption has been shown to improve peripheral vascular function. Its effect on brain vasculature is unknown, though tea contains small amounts of caffeine, a psychoactive substance known to influence cerebral blood flow (CBF). We investigated the effects on CBF due to the intake of tea components in 20 healthy men in a double-blinded, randomized, placebo-controlled study. On separate days, subjects received a single dose of 184 mg caffeine (equivalent to one strong espresso coffe...

  7. SU-E-I-65: Estimation of Tagging Efficiency in Pseudo-Continuous Arterial Spin Labeling (pCASL) MRI

    International Nuclear Information System (INIS)

    Purpose: pCASL was recommended as a potent approach for absolute cerebral blood flow (CBF) quantification in clinical practice. However, uncertainties of tagging efficiency in pCASL remain an issue. This study aimed to estimate tagging efficiency by using short quantitative pulsed ASL scan (FAIR-QUIPSSII) and compare resultant CBF values with those calibrated by using 2D Phase Contrast (PC) MRI. Methods: Fourteen normal volunteers participated in this study. All images, including whole brain (WB) pCASL, WB FAIR-QUIPSSII and single-slice 2D PC, were collected on a 3T clinical MRI scanner with a 8-channel head coil. DeltaM map was calculated by averaging the subtraction of tag/control pairs in pCASL and FAIR-QUIPSSII images and used for CBF calculation. Tagging efficiency was then calculated by the ratio of mean gray matter CBF obtained from pCASL and FAIR-QUIPSSII. For comparison, tagging efficiency was also estimated with 2D PC, a previously established method, by contrast WB CBF in pCASL and 2D PC. Feasibility of estimation from a short FAIR-QUIPSSII scan was evaluated by number of averages required for obtaining a stable deltaM value. Setting deltaM calculated by maximum number of averaging (50 pairs) as reference, stable results were defined within ±10% variation. Results: Tagging efficiencies obtained by 2D PC MRI (0.732±0.092) were significantly lower than which obtained by FAIRQUIPPSSII (0.846±0.097) (P<0.05). Feasibility results revealed that four pairs of images in FAIR-QUIPPSSII scan were sufficient to obtain a robust calibration of less than 10% differences from using 50 pairs. Conclusion: This study found that reliable estimation of tagging efficiency could be obtained by a few pairs of FAIR-QUIPSSII images, which suggested that calibration scan in a short duration (within 30s) was feasible. Considering recent reports concerning variability of PC MRI-based calibration, this study proposed an effective alternative for CBF quantification with pCASL

  8. Interactions of 14N:15N stearic acid spin-label pairs: effects of host lipid alkyl chain length and unsaturation

    International Nuclear Information System (INIS)

    Electron-electron double resonance (ELDOR) and saturation recovery electron paramagnetic resonance (EPR) spectroscopy have been employed to examine the interactions of 14N:15N stearic acid spin-label pairs in fluid-phase model membrane bilayers composed of a variety of phospholipids. The [14N]-16-doxylstearate:[15N]-16-doxylstearate (16:16) pair was utilized to measure lateral diffusion of the spin-labels, while the [14N]-16-doxylstearate:[15N]-5-doxylstearate (16:5) pair provided information on vertical fluctuations of the 16-doxylstearate nitroxide moiety toward the membrane surface. Three saturated host lipids of varying alkyl chain length [dimyristoylphosphatidylcholine (DMPC), dipalmitoylphosphatidylcholine (DPPC), and distearoylphosphatidylcholine (DSPC)], an α-saturated, β-unsaturated lipid [1-palmitoyl-2-oleoylphosphatidylcholine (POPC)], and phosphatidylcholine from a natural source [egg yolk phosphatidylcholine (egg PC)] were utilized as host lipids. Lateral diffusion of the stearic acid spin-labels was only slightly affected by alkyl chain length at a given reduced temperature (T/sub r/) in the saturated host lipids but was significantly decreased in POPC at the same T/sub r/. Lateral diffusion in DMPC, POPC, and egg PC was quite similar at 370C. A strong correlation was noted between lateral diffusion constants and rotational mobility of [14N]-16-doxylstearate. Vertical fluctuations were likewise only slightly influenced by alklyl chain length but were strongly diminished in POPC and egg PC relative to the saturated systems. This diminution of the 16:5 interaction was observed even under conditions where no differences were discernible by conventional EPR

  9. Identification of pH-sensitive regions in the mouse prion by the cysteine-scanning spin-labeling ESR technique

    International Nuclear Information System (INIS)

    We analyzed the pH-induced mobility changes in moPrPC α-helix and β-sheets by cysteine-scanning site-directed spin labeling (SDSL) with ESR. Nine amino acid residues of α-helix1 (H1, codon 143-151), four amino acid residues of β-sheet1 (S1, codon 127-130), and four amino acid residues of β-sheet2 (S2, codon 160-163) were substituted for by cysteine residues. These recombinant mouse PrPC (moPrPC) mutants were reacted with a methane thiosulfonate sulfhydryl-specific spin labeling reagent (MTSSL). The 1/δH of the central (14N hyperfine) component (MI = 0) in the ESR spectrum of spin-labeled moPrPC was measured as a mobility parameter of nitroxide residues (R1). The mobilities of E145R1 and Y149R1 at pH 7.4, which was identified as a tertiary contact site by a previous NMR study of moPrP, were lower than those of D143R1, R147R1, and R150R1 reported on the helix surface. Thus, the mobility in the H1 region in the neutral solution was observed with the periodicity associated with a helical structure. On the other hand, the values in the S2 region, known to be located in the buried side, were lower than those in the S1 region located in the surface side. These results indicated that the mobility parameter of the nitroxide label was well correlated with the 3D structure of moPrP. Furthermore, the present study clearly demonstrated three pH-sensitive sites in moPrP, i.e. (1) the N-terminal tertiary contact site of H1 (2) the C-terminal end of H1, and (3) the S2 region. In particular, among these pH-sensitive sites, the N-terminal tertiary contact region of H1 was found to be the most pH-sensitive one and was easily converted to a flexible structure by a slight decrease of pH in the solution. These data provided molecular evidence to explain the cellular mechanism for conversion from PrPC to PrPSc in acidic organelles such as the endosome

  10. Non-enhanced artery depiction of the finger using time-slip method. Presidental award proceedings

    International Nuclear Information System (INIS)

    In the past, we have been reported visualization of the artery of the finger using flow-spoiled flesh blood imaging (FBI) technique without using contrast medium in this society. In this study, we use time-spatial labeling inversion tag pulse (Time-SLIP) with peripheral-triggered 3 dimension half-Fourier single shot fast spin echo (FSE) for visualization of the artery of the finger. Time-SLIP is one of the arterial spin labeling (ASL) techniques, that allows an alternative acquisition of a spatial-selective inversion recovery (IR) tag-on and tag-off pulse for separation of arteries from veins. The subtraction of the tag-on images from the tag-off images allows only the tagged images at the TI. All signals outside the tag region are subtracted but for the signal of blood that moved from tagged region. Using labeling pulse at the TI on null point of blood, the tagged image shows maximum signal intensity of the artery. The length of the artery from the tagged area depends on the speed of the blood flow of the artery, longer artery of the subtraction image means keeping faster blood flow. Using longer TI than null point of blood, subtraction images visualize longer artery, but the signal of blood become lower because of the T1 relaxation of blood. Inverting by a spatial-selective IR tag-on pulse on just before the excitation time of heart is important to visualize the longer artery of finger, because the TI that means moving period of blood is only 1000 ms. (author)

  11. Preparation, characterization and magnetic behavior of a spin-labelled physical hydrogel containing a chiral cyclic nitroxide radical unit fixed inside the gelator molecule.

    Science.gov (United States)

    Takemoto, Yusa; Yamamoto, Takayuki; Ikuma, Naohiko; Uchida, Yoshiaki; Suzuki, Katsuaki; Shimono, Satoshi; Takahashi, Hiroki; Sato, Nobuhiro; Oba, Yojiro; Inoue, Rintaro; Sugiyama, Masaaki; Tsue, Hirohito; Kato, Tatsuhisa; Yamauchi, Jun; Tamura, Rui

    2015-07-21

    An optically active amphiphilic nitroxide radical compound [(S,S,R)-], which contains a paramagnetic (2S,5S)-2,5-dimethyl-2,5-diphenylpyrrolidine-N-oxyl radical group fixed in the inner position together with a hydrophobic long alkyl chain and a hydrophilic (R)-alanine residue in the opposite terminal positions, was found to serve as a low-molecular-weight gelator in H2O to give rise to a spin-labelled physical hydrogel. Characterization of the hydrogel was performed by microscopic (SEM, TEM and AFM) techniques, XRD and SAXS measurements, and IR, UV and CD spectroscopies. The gel-sol transition temperature was determined by EPR spectral line-width (ΔHpp) analysis. Measurement of the temperature dependence of relative paramagnetic susceptibility (χrel) for the hydrogel and sol phases was achieved by means of the double-integration of VT-EPR spectra. PMID:26073537

  12. 82Rb PET myocardial perfusion imaging is superior to 99mTc-labelled agent SPECT in patients with known or suspected coronary artery disease

    International Nuclear Information System (INIS)

    We compared the quality, interpretive confidence and interreader agreement between SPECT and PET myocardial perfusion imaging (MPI) in the same group of patients. The study group comprised 27 patients (age 55 ± 8.5 years, 12 men) with known or suspected coronary artery disease (CAD) who had undergone gated rest/stress MPI with 99mTc-labelled agent SPECT (with and without attenuation correction, AC), and subsequent clinical confirmation with 82Rb PET. Three experienced readers blinded to the clinical information interpreted all MPI studies. Interreader agreement was significantly superior for PET studies than for SPECT studies. Following consensus interpretation, the quality of 22 % of the non-AC SPECT studies, 33 % of the AC SPECT studies and 63 % of the PET studies was assessed as excellent or good (p = 0.016). Interpretations were definitely normal or abnormal in 7 % of non-AC SPECT studies, 30 % of AC SPECT studies and 85 % of PET studies (p = 0.046). In 13 patients who had received either invasive coronary angiography or CT angiography with no significant CAD, the true-positive rate for significant CAD was higher for PET, and the true-negative rate was equal for PET and AC SPECT, and lower for non-AC SPECT. 82Rb PET MPI, used as a confirmatory test after SPECT, offers improved image quality, interpretive confidence and interreader agreement. (orig.)

  13. Spin-label CW microwave power saturation and rapid passage with triangular non-adiabatic rapid sweep (NARS) and adiabatic rapid passage (ARP) EPR spectroscopy

    Science.gov (United States)

    Kittell, Aaron W.; Hyde, James S.

    2015-06-01

    Non-adiabatic rapid passage (NARS) electron paramagnetic resonance (EPR) spectroscopy was introduced by Kittell et al. (2011) as a general purpose technique to collect the pure absorption response. The technique has been used to improve sensitivity relative to sinusoidal magnetic field modulation, increase the range of inter-spin distances that can be measured under near physiological conditions (Kittell et al., 2012), and enhance spectral resolution in copper (II) spectra (Hyde et al., 2013). In the present work, the method is extended to CW microwave power saturation of spin-labeled T4 Lysozyme (T4L). As in the cited papers, rapid triangular sweep of the polarizing magnetic field was superimposed on slow sweep across the spectrum. Adiabatic rapid passage (ARP) effects were encountered in samples undergoing very slow rotational diffusion as the triangular magnetic field sweep rate was increased. The paper reports results of variation of experimental parameters at the interface of adiabatic and non-adiabatic rapid sweep conditions. Comparison of the forward (up) and reverse (down) triangular sweeps is shown to be a good indicator of the presence of rapid passage effects. Spectral turning points can be distinguished from spectral regions between turning points in two ways: differential microwave power saturation and differential passage effects. Oxygen accessibility data are shown under NARS conditions that appear similar to conventional field modulation data. However, the sensitivity is much higher, permitting, in principle, experiments at substantially lower protein concentrations. Spectral displays were obtained that appear sensitive to rotational diffusion in the range of rotational correlation times of 10-3 to 10-7 s in a manner that is analogous to saturation transfer spectroscopy.

  14. Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jinhee; Kim, Bom-yi; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin; Kim, Bum-soo [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, Seoul (Korea, Republic of); Schmitt, Peter [Siemens AG, Healthcare Sector, Erlangen (Germany); Kim, Inseong; Paek, Munyoung [Siemens AG, Healthcare, Seoul (Korea, Republic of)

    2014-04-15

    This study aimed to evaluate the feasibility of non-contrast-enhanced 4D magnetic resonance angiography (NCE 4D MRA) with signal targeting with alternative radiofrequency (STAR) spin labeling and variable flip angle (VFA) sampling in the assessment of dural arteriovenous fistula (DAVF) in the transverse sinus. Nine patients underwent NCE 4D MRA for the evaluation of DAVF in the transverse sinus at 3 T. One patient was examined twice, once before and once after the interventional treatment. All patients also underwent digital subtraction angiography (DSA) and/or contrast-enhanced magnetic resonance angiography (CEMRA). For the acquisition of NCE 4D MRA, a STAR spin tagging method was used, and a VFA sampling was applied in the data readout module instead of a constant flip angle. Two readers evaluated the NCE 4D MRA data for the diagnosis of DAVF and its type with consensus. The results were compared with those from DSA and/or CEMRA. All patients underwent NCE 4D MRA without any difficulty. Among seven patients with patent DAVFs, all cases showed an early visualization of the transverse sinus on NCE 4D MRA. Except for one case, the type of DAVF of NCE 4D MRA was agreed with that of reference standard study. Cortical venous reflux (CVR) was demonstrated in two cases out of three patients with CVR. NCE 4D MRA with STAR tagging and VFA sampling is technically and clinically feasible and represents a promising technique for assessment of DAVF in the transverse sinus. Further technical developments should aim at improvements of spatial and temporal coverage. (orig.)

  15. Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula

    International Nuclear Information System (INIS)

    This study aimed to evaluate the feasibility of non-contrast-enhanced 4D magnetic resonance angiography (NCE 4D MRA) with signal targeting with alternative radiofrequency (STAR) spin labeling and variable flip angle (VFA) sampling in the assessment of dural arteriovenous fistula (DAVF) in the transverse sinus. Nine patients underwent NCE 4D MRA for the evaluation of DAVF in the transverse sinus at 3 T. One patient was examined twice, once before and once after the interventional treatment. All patients also underwent digital subtraction angiography (DSA) and/or contrast-enhanced magnetic resonance angiography (CEMRA). For the acquisition of NCE 4D MRA, a STAR spin tagging method was used, and a VFA sampling was applied in the data readout module instead of a constant flip angle. Two readers evaluated the NCE 4D MRA data for the diagnosis of DAVF and its type with consensus. The results were compared with those from DSA and/or CEMRA. All patients underwent NCE 4D MRA without any difficulty. Among seven patients with patent DAVFs, all cases showed an early visualization of the transverse sinus on NCE 4D MRA. Except for one case, the type of DAVF of NCE 4D MRA was agreed with that of reference standard study. Cortical venous reflux (CVR) was demonstrated in two cases out of three patients with CVR. NCE 4D MRA with STAR tagging and VFA sampling is technically and clinically feasible and represents a promising technique for assessment of DAVF in the transverse sinus. Further technical developments should aim at improvements of spatial and temporal coverage. (orig.)

  16. Structural transitions in full-length human prion protein detected by xenon as probe and spin labeling of the N-terminal domain

    Science.gov (United States)

    Narayanan, Sunilkumar Puthenpurackal; Nair, Divya Gopalakrishnan; Schaal, Daniel; Barbosa de Aguiar, Marisa; Wenzel, Sabine; Kremer, Werner; Schwarzinger, Stephan; Kalbitzer, Hans Robert

    2016-01-01

    Fatal neurodegenerative disorders termed transmissible spongiform encephalopathies (TSEs) are associated with the accumulation of fibrils of misfolded prion protein PrP. The noble gas xenon accommodates into four transiently enlarged hydrophobic cavities located in the well-folded core of human PrP(23–230) as detected by [1H, 15N]-HSQC spectroscopy. In thermal equilibrium a fifth xenon binding site is formed transiently by amino acids A120 to L125 of the presumably disordered N-terminal domain and by amino acids K185 to T193 of the well-folded domain. Xenon bound PrP was modelled by restraint molecular dynamics. The individual microscopic and macroscopic dissociation constants could be derived by fitting the data to a model including a dynamic opening and closing of the cavities. As observed earlier by high pressure NMR spectroscopy xenon binding influences also other amino acids all over the N-terminal domain including residues of the AGAAAAGA motif indicating a structural coupling between the N-terminal domain and the core domain. This is in agreement with spin labelling experiments at positions 93 or 107 that show a transient interaction between the N-terminus and the start of helix 2 and the end of helix 3 of the core domain similar to that observed earlier by Zn2+-binding to the octarepeat motif. PMID:27341298

  17. Assessment of anatomic morphology of the connective structures among brain ventricles and cerebrospinal fluid movement in them by cerebrospinal fluid spin-labeling MRI

    International Nuclear Information System (INIS)

    Objective: To assess the anatomic morphology of the connective structures among brain ventricles and cerebrospinal fluid (CSF) movement in them by CSF spin-labeling MR imaging. Methods: According to the order of registration, 50 healthy volunteers were randomly selected and received cerebrospinal fluid spin-labeling MR scan with time-spatial labeling inversion recovery single-shot fast spin echo sequence (SLIR-SSFSE). The tagged CSF was used as an endogenous tracer. The anatomic morphology of the connective structures of brain ventricles and the flow direction of CSF were observed. The longitudinal diameter and transverse diameter of bilateral foramina of monro, midbrain aqueduct, and the central and bilateral lateral apertures of the fourth ventricle of each subject were measured and calculated based on multiple measurements. The flow rate of CSF was calculated based on the flow distance of CSF in the connective structures between brain ventricles during different TI time. The mean value of each indicator was acquired. Results: Two-way flow state of CSF was observed in all connective structures, including bilateral foramina of monro, midbrain aqueduct, and the central and bilateral lateral apertures of the fourth ventricle. On the coronal planes, foramen of monro appears as a 'Y'-type tubular structure locating among the both sides of the anteriomedial thalamus and fornix, which connect upward with bilateral lateral ventricles and downward with the third ventricle. The longitudinal diameter and transverse diameter of the left side of foramen of monro were 3.50-5.50 mm [mean (4.37±0.47) mm] and 1.00-1.40 mm [mean (1.21± 0.13) mm], respectively. The longitudinal diameter and transverse diameter of the right side of foramen of' monro were 4.20-4.80 mm [mean (4.42±0.20) mm] and 1.00-1.60 mm [mean (1.21± 0.19) mm], respectively. On the sagittal planes, foramen of monro appeared as an oblique fine tubular structure with the angle of 55°-58° between the both sides

  18. MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence

    International Nuclear Information System (INIS)

    We investigated the efficacy of three-dimensional black blood T1-weighted imaging (3D-BB-T1WI) using a variable refocusing flip angle turbo spin-echo sequence in the diagnosis of intracranial vertebral artery dissection (VAD). Sixteen consecutive patients diagnosed with intracranial VAD underwent magnetic resonance imaging that included 3D time-of-flight-MRA, axial spin-echo T1-weighted images (SE-T1WI) and oblique coronal 3D-BB-T1WI sequences. The visualization, morphology and extent of intramural haematomas were assessed and compared among the sequences. Results obtained by digital subtraction angiography (DSA), 3D-angiography and/or 3D-CT angiography (CTA) were used as standards of reference. 3D-BB-T1WI revealed intramural haematomas in all cases, whereas SE-T1WI and magnetic resonance angiography (MRA) failed to reveal a haematoma in one case and three cases, respectively. The mean visualization grading score for the intramural haematoma was the highest for 3D-BB-T1WI, and there was a statistically significant difference among the sequences (p < 0.001). At least a portion of the intramural haematoma was distinguishable from the lumen on 3D-BB-T1WI, whereas the haematomas were entirely indistinguishable from intraluminal signals on MRA in two cases (12.5 %) and on SE-T1WI in one case (6.3 %). 3D-BB-T1WI revealed the characteristic crescent shape of the intramural haematoma in 14 cases (87.5 %), whereas SE-T1WI and MRA revealed a crescent shape in only 7 cases (43.8 %) and 8 cases (50 %), respectively. In a consensus reading, 3D-BB-T1WI was considered the most consistent sequence in representing the extent and morphology of the lesion in 14 cases (87.5 %), compared to DSA and CTA. 3D-BB-T1WI is a promising method to evaluate intramural haematoma in patients with suspected intracranial VAD. (orig.)

  19. Feasibility of Quantifying Arterial Cerebral Blood Volume Using Multiphase Alternate Ascending/Descending Directional Navigation (ALADDIN).

    Science.gov (United States)

    Kim, Ki Hwan; Choi, Seung Hong; Park, Sung-Hong

    2016-01-01

    Arterial cerebral blood volume (aCBV) is associated with many physiologic and pathologic conditions. Recently, multiphase balanced steady state free precession (bSSFP) readout was introduced to measure labeled blood signals in the arterial compartment, based on the fact that signal difference between labeled and unlabeled blood decreases with the number of RF pulses that is affected by blood velocity. In this study, we evaluated the feasibility of a new 2D inter-slice bSSFP-based arterial spin labeling (ASL) technique termed, alternate ascending/descending directional navigation (ALADDIN), to quantify aCBV using multiphase acquisition in six healthy subjects. A new kinetic model considering bSSFP RF perturbations was proposed to describe the multiphase data and thus to quantify aCBV. Since the inter-slice time delay (TD) and gap affected the distribution of labeled blood spins in the arterial and tissue compartments, we performed the experiments with two TDs (0 and 500 ms) and two gaps (300% and 450% of slice thickness) to evaluate their roles in quantifying aCBV. Comparison studies using our technique and an existing method termed arterial volume using arterial spin tagging (AVAST) were also separately performed in five subjects. At 300% gap or 500-ms TD, significant tissue perfusion signals were demonstrated, while tissue perfusion signals were minimized and arterial signals were maximized at 450% gap and 0-ms TD. ALADDIN has an advantage of visualizing bi-directional flow effects (ascending/descending) in a single experiment. Labeling efficiency (α) of inter-slice blood flow effects could be measured in the superior sagittal sinus (SSS) (20.8±3.7%.) and was used for aCBV quantification. As a result of fitting to the proposed model, aCBV values in gray matter (1.4-2.3 mL/100 mL) were in good agreement with those from literature. Our technique showed high correlation with AVAST, especially when arterial signals were accentuated (i.e., when TD = 0 ms) (r = 0

  20. Feasibility of Quantifying Arterial Cerebral Blood Volume Using Multiphase Alternate Ascending/Descending Directional Navigation (ALADDIN)

    Science.gov (United States)

    Kim, Ki Hwan; Choi, Seung Hong; Park, Sung-Hong

    2016-01-01

    Arterial cerebral blood volume (aCBV) is associated with many physiologic and pathologic conditions. Recently, multiphase balanced steady state free precession (bSSFP) readout was introduced to measure labeled blood signals in the arterial compartment, based on the fact that signal difference between labeled and unlabeled blood decreases with the number of RF pulses that is affected by blood velocity. In this study, we evaluated the feasibility of a new 2D inter-slice bSSFP-based arterial spin labeling (ASL) technique termed, alternate ascending/descending directional navigation (ALADDIN), to quantify aCBV using multiphase acquisition in six healthy subjects. A new kinetic model considering bSSFP RF perturbations was proposed to describe the multiphase data and thus to quantify aCBV. Since the inter-slice time delay (TD) and gap affected the distribution of labeled blood spins in the arterial and tissue compartments, we performed the experiments with two TDs (0 and 500 ms) and two gaps (300% and 450% of slice thickness) to evaluate their roles in quantifying aCBV. Comparison studies using our technique and an existing method termed arterial volume using arterial spin tagging (AVAST) were also separately performed in five subjects. At 300% gap or 500-ms TD, significant tissue perfusion signals were demonstrated, while tissue perfusion signals were minimized and arterial signals were maximized at 450% gap and 0-ms TD. ALADDIN has an advantage of visualizing bi-directional flow effects (ascending/descending) in a single experiment. Labeling efficiency (α) of inter-slice blood flow effects could be measured in the superior sagittal sinus (SSS) (20.8±3.7%.) and was used for aCBV quantification. As a result of fitting to the proposed model, aCBV values in gray matter (1.4–2.3 mL/100 mL) were in good agreement with those from literature. Our technique showed high correlation with AVAST, especially when arterial signals were accentuated (i.e., when TD = 0 ms) (r = 0

  1. Spectroscopic Evidence for Covalent Binding of Sulfadiazine to Natural Soils via 1,4-nucleophilic addition (Michael Type Addition) studied by Spin Labeling ESR

    Science.gov (United States)

    Aleksandrova, Olga

    2015-04-01

    Among different classes of veterinary pharmaceuticals, Sulfadiazine (SDZ) is widely used in animal husbandry. Its residues were detected in different environmental compartments. However, soil is a hot spot for SDZ as it receives a large portion of excreted compounds through the application of manure during soil fertilization. Ample studies on the fate of SDZ in soils showed that a large portion forms nonextractable residues (NER) along with transformation products and a low mineralization (Mueller et al., 2013). A common observation was an initially fast formation of NER up to 10% of the applied amount promptly after the application of SDZ to soil, and this portion increased up to 50% within a few days (Mueller et al., 2013; Nowak et al., 2011). A common finding for SDZ, as for other sulfonamides, was biphasic kinetics of the formation of NER, which was attributed to the occurrence of two reaction processes: a rapid, often reversible process and a slower, irreversible process (Weber et al., 1996). A single-phase reaction process was also established under anaerobic treatment (Gulkowska et al., 2014). A major focus of this work is to elucidate a reaction mechanism of covalent binding of SDZ to soil that is currently required to estimate a risk of NER formed by SDZ in soils for human health. Taking into account a key role of the amine functional groups of SDZ on its reactivity in soil, nitroxide radicals with the sewed aromatic or aliphatic amines labeled soil samples and then, were investigated by means of ESR spectroscopy. 2,5,5-Trimethyl-2-(3-aminophenyl)pyrrolidin-1-yloxy and 4-amino-2,2,6,6-Tetramethylpiperidin-1-oxyl modeled decomposition products of SDZ with the aromatic and aliphatic amines, respectively. The application of the defined combination of both spin labels (SL) to different soils well simulated a change of a paramagnetic signal of soil organic radicals interacted with SDZ. After their application to soil, SL were found in soil sites characterized

  2. Coherent spin-networks

    International Nuclear Information System (INIS)

    In this paper we discuss a proposal of coherent states for loop quantum gravity. These states are labeled by a point in the phase space of general relativity as captured by a spin-network graph. They are defined as the gauge-invariant projection of a product over links of Hall's heat kernels for the cotangent bundle of SU(2). The labels of the state are written in terms of two unit vectors, a spin and an angle for each link of the graph. The heat-kernel time is chosen to be a function of the spin. These labels are the ones used in the spin-foam setting and admit a clear geometric interpretation. Moreover, the set of labels per link can be written as an element of SL(2,C). These states coincide with Thiemann's coherent states with the area operator as complexifier. We study the properties of semiclassicality of these states and show that, for large spins, they reproduce a superposition over spins of spin-networks with nodes labeled by Livine-Speziale coherent intertwiners. Moreover, the weight associated to spins on links turns out to be given by a Gaussian times a phase as originally proposed by Rovelli.

  3. 自旋标记查耳酮类化合物的合成及抗肿瘤活性%Synthesis and biological evaluation of spin-labelled derivatives of chalcones

    Institute of Scientific and Technical Information of China (English)

    金岩; 刘杰; 陈世武

    2013-01-01

    目的 发现高效自旋标记查耳酮类抗肿瘤药物.方法 通过乙酰苯与芳醛在碱性条件下缩合生成查耳酮,进一步与稳定氮氧自由基酸发生酰化反应合成了一系列自旋标记的查耳酮化合物,用MTT法对合成的化合物进行体外抗肿瘤活性研究(P3SS、A549、HT-29、MDA-MB-231、8GC-7901、BEL-7402).结果 化合物3a和3c在10 μg/mL时对所有测试瘤株的抑制率均大于60%.结论 自旋标记的查耳酮酰胺类化合物具有较高的体外抗肿瘤活性.%Objective To find new spin labelled chalcones as anti-tumor drugs with potent activities and low toxicities. Methods A series spin labelled chalcones were synthesized by condensation reaction of aromatic aldehyde and acetpophenone, following acetylation. The cytotoxic activities against six tumor cell lines (P388, A-549, HT-29, MDA-MB-231, SGC-7901, BEL-7402) in vitro of synthetic compounds were also evaluated by MTT method. Results Compounds 3a and 3c showed more than 60% proliferation inhibitions against all six tested tumor cell lines in vitro. Conclusion The amides of spin-labelled chalcones present better anti-tumor activities in vitro.

  4. Arterial Catheterization

    Science.gov (United States)

    ... version AMERICAN THORACIC SOCIETY Patient Information Series Arterial Catheterization An arterial catheter is a thin, hollow tube ... PHYSICIANS: AND COPY Why Do I Need Arterial Catheterization? Common reasons an arterial catheterization is done include: ■ ...

  5. Dynamic nuclear spin polarization

    International Nuclear Information System (INIS)

    Polarized neutron scattering from dynamic polarized targets has been applied to various hydrogenous materials at different laboratories. In situ structures of macromolecular components have been determined by nuclear spin contrast variation with an unprecedented precision. The experiments of selective nuclear spin depolarisation not only opened a new dimension to structural studies but also revealed phenomena related to propagation of nuclear spin polarization and the interplay of nuclear polarisation with the electronic spin system. The observation of electron spin label dependent nuclear spin polarisation domains by NMR and polarized neutron scattering opens a way to generalize the method of nuclear spin contrast variation and most importantly it avoids precontrasting by specific deuteration. It also likely might tell us more about the mechanism of dynamic nuclear spin polarisation. (author) 4 figs., refs

  6. Dynamic nuclear spin polarization

    Energy Technology Data Exchange (ETDEWEB)

    Stuhrmann, H.B. [GKSS-Forschungszentrum Geesthacht GmbH (Germany)

    1996-11-01

    Polarized neutron scattering from dynamic polarized targets has been applied to various hydrogenous materials at different laboratories. In situ structures of macromolecular components have been determined by nuclear spin contrast variation with an unprecedented precision. The experiments of selective nuclear spin depolarisation not only opened a new dimension to structural studies but also revealed phenomena related to propagation of nuclear spin polarization and the interplay of nuclear polarisation with the electronic spin system. The observation of electron spin label dependent nuclear spin polarisation domains by NMR and polarized neutron scattering opens a way to generalize the method of nuclear spin contrast variation and most importantly it avoids precontrasting by specific deuteration. It also likely might tell us more about the mechanism of dynamic nuclear spin polarisation. (author) 4 figs., refs.

  7. Clinical result of intra-arterial lymphocyte injection therapy for treatment of lymphedema and the evaluation of the efficacy of the therapy. Quantitative analysis by an injection of {sup 111}In-labeled lymphocytes and by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Masanori; Kitagawa, Tetsuya; Hori, Takaki; Katoh, Itsuo; Harada, Masashi; Matsumoto, Takahiro; Nishitani, Hiromu [Tokushima Univ. (Japan). School of Medicine

    1995-11-01

    We have employed the intra-arterial lymphocytes injection therapy for treatment of lymphedema of the limbs with various causes. In the present study, we observed the clinical outcome of our therapy in 38 patients with lymphedema of the limbs. Results showed that the therapy was effective in 26 of 38 patients (68% of the total). Moreover, a marked efficacy was obtained in 13 of 38 patients (34% of the total). In the latest 5 patients, to evaluate the efficacy of our therapy, we examined the distribution of the {sup 111}In-oxine labeled lymphocytes injected into the proximal artery of the affected limb. The radioactivities of the affected limbs were apparently higher than that of the healthy limbs in effective cases. Moreover, MR imaging showed that the reduction of STIR ratio and T{sub 2} ratio well correlate with the results of clinical course. Thus, the efficacy of the lymphocyte injection therapy is able to be evaluated by radiolabeled lymphocytes and MR imaging. (author).

  8. Inverse correlation between cerebral blood flow measured by continuous arterial spin-labeling (CASL) MRI and neurocognitive function in children with sickle cell anemia (SCA)

    OpenAIRE

    Strouse, John J.; Cox, Christiane S.; Melhem, Elias R.; Lu, Hanzhang; Kraut, Michael A.; Razumovsky, Alexander; Yohay, Kaleb; van Zijl, Peter C.; Casella, James F.

    2006-01-01

    Overt stroke, clinically “silent” cerebral infarct, and neurocognitive impairment are frequent complications of sickle cell anemia (SCA). Current imaging techniques have limited sensitivity and specificity to identify children at risk for neurocognitive impairment. We prospectively evaluated 24 children with SCA with a neurologic exam, complete blood count, transcranial Doppler ultrasound (TCD), measurement of intelligence quotient (IQ), and magnetic resonance imaging (MRI) with measurement o...

  9. Cerebral metabolism and perfusion in MR-negative individuals with refractory focal epilepsy assessed by simultaneous acquisition of 18F-FDG PET and arterial spin labeling

    OpenAIRE

    Galazzo, I. B.; Mattoli, M. V.; Pizzini, F. B.; Vita, E.; Barnes, A.; Duncan, J.S.; Jager, R.; Golay, X.; Bomanji, J. B.; Koepp, M.; Groves, A M; Fraioli, F.

    2016-01-01

    The major challenge in pre-surgical epileptic patient evaluation is the correct identification of the seizure onset area, especially in MR-negative patients. In this study, we aimed to: (1) assess the concordance between perfusion, from ASL, and metabolism, from 18F-FDG, acquired simultaneously on PET/MR; (2) verify the utility of a statistical approach as supportive diagnostic tool for clinical readers. Secondarily, we compared 18F-FDG PET data from the hybrid PET/MR system with those acquir...

  10. Cerebral metabolism and perfusion in MR-negative individuals with refractory focal epilepsy assessed by simultaneous acquisition of (18)F-FDG PET and arterial spin labeling.

    Science.gov (United States)

    Boscolo Galazzo, Ilaria; Mattoli, Maria Vittoria; Pizzini, Francesca Benedetta; De Vita, Enrico; Barnes, Anna; Duncan, John S; Jäger, Hans Rolf; Golay, Xavier; Bomanji, Jamshed B; Koepp, Matthias; Groves, Ashley M; Fraioli, Francesco

    2016-01-01

    The major challenge in pre-surgical epileptic patient evaluation is the correct identification of the seizure onset area, especially in MR-negative patients. In this study, we aimed to: (1) assess the concordance between perfusion, from ASL, and metabolism, from (18)F-FDG, acquired simultaneously on PET/MR; (2) verify the utility of a statistical approach as supportive diagnostic tool for clinical readers. Secondarily, we compared (18)F-FDG PET data from the hybrid PET/MR system with those acquired with PET/CT, with the purpose of validate the reliability of (18)F-FDG PET/MR data. Twenty patients with refractory focal epilepsy, negative MR and a defined electro-clinical diagnosis underwent PET/MR, immediately followed by PET/CT. Standardized uptake value ratio (SUVr) and cerebral blood flow (CBF) maps were calculated for PET/CT-PET/MR and ASL, respectively. For all techniques, z-score of the asymmetry index (zAI) was applied for depicting significant Right/Left differences. SUVr and CBF images were firstly visually assessed by two neuroimaging readers, who then re-assessed them considering zAI for reaching a final diagnosis. High agreement between (18)F-FDG PET/MR and ASL was found, showing hypometabolism and hypoperfusion in the same hemisphere in 18/20 patients, while the remaining were normal. They were completely concordant in 14/18, concordant in at least one lobe in the remaining. zAI maps improved readers' confidence in 12/20 and 15/20 patients for (18)F-FDG PET/MR and ASL, respectively. (18)F-FDG PET/CT-PET/MR showed high agreement, especially when zAI was considered. The simultaneous metabolism-perfusion acquisition provides excellent concordance on focus lateralisation and good concordance on localisation, determining useful complementary information. PMID:27222796

  11. Effects of iloprost combined with low dose tadalafil in adult congenital heart disease patients with severe pulmonary arterial hypertension: a single-center,open-label controlled study

    Institute of Scientific and Technical Information of China (English)

    张曹进

    2014-01-01

    Objective To evaluate the therapy efficacy of iloprost combined with low dose tadalafil in adult congenital heart disease(CHD)patients with severe pulmonary arterial hypertension(PAH).Methods Adult CHD patients with severe PAH were included and divided into the sequential combination therapy group[iloprost:10μg/inhalation,6 times per day for 6 months,and then add oral tadalafil(5 mg/d)till 12 months,n=32]and upfront combination therapy group[iloprost:10μg/inhalation,6 times per day combined with oral tadalafil(5 mg)

  12. Arterial stick

    Science.gov (United States)

    ... the main arteries in the forearm (radial and ulnar arteries). The procedure is done as follows: The ... Arteries also have thicker walls and have more nerves. When the needle is inserted, there may be ...

  13. Food Labels

    Science.gov (United States)

    ... How Can I Help a Friend Who Cuts? Food Labels KidsHealth > For Teens > Food Labels Print A ... have at least 95% organic ingredients. continue Making Food Labels Work for You The first step in ...

  14. Hepatic artery injection of {sup 131}I-labelled metuximab combined with chemoembolization for intermediate hepatocellular carcinoma: a prospective nonrandomized study

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Lu; Yang, Ye-Fa; Ge, Nai-Jian; Shen, Shu-Qun; Liang, Jun [Second Military Medical University, The First Department of Interventional Radiology, Eastern Hepatobiliary Surgery Hospital, Shanghai (China); Wang, Yi [Second Military Medical University, The Second Department of Hepatic Surgery, Eastern Hepatobiliary Surgery Hospital, Shanghai (China); Zhou, Wei-Ping [Second Military Medical University, The Third Department of Hepatic Surgery, Eastern Hepatobiliary Surgery Hospital, Shanghai (China); Shen, Feng; Wu, Meng-Chao [Second Military Medical University, Eastern Hepatobiliary Surgery Hospital, Shanghai (China)

    2012-08-15

    Hepatocellular carcinoma (HCC) is the fifth and seventh most common cause of cancer in men and women, respectively. Transcatheter arterial chemoembolization (TACE) is the standardized therapy for the intermediate stage of HCC. However, the 3-year overall survival remains low (<30 %) in these patients. Thus, there is a critical need for the development of treatment modalities to improve the survival rate. This study aimed to evaluate whether the combination of {sup 131}I-metuximab with chemoembolization could improve treatment efficiency. Between January 2009 and January 2010, a prospective two-arm nonrandomized study was performed in patients with intermediate HCC. Of 138 patients, 68 (combination therapy group) received 132 courses of intraarterial {sup 131}I-metuximab injections combined with chemoembolization (mean 1.94 per patient, median 2, range 1-2), followed by 152 sessions of TACE (mean 2.24 per patient, median 2, range 0-4). The remaining 70 patients (monotherapy group) received 296 sessions of TACE (mean 4.23 per patient, median 4, range 1-7). The overall median survival times for the combination therapy group and the group treated only with TACE were 26.7 months (95 % CI 20.7-31.3 months) and 20.6 months (95 % CI 15.3-24.7 months), respectively. The combination therapy group had a significantly higher survival rate than the TACE-only group (P = 0.038). Age {>=}65 years, serum albumin {<=}35 g/l, and treatment category (combination therapy or TACE only) were independent prognostic factors for survival according to multivariate analysis. The combination of {sup 131}I-metuximab and chemoembolization extended survival in patients with intermediate HCC compared with TACE only, and was well tolerated by patients with Child-Pugh class A or B disease. This combination seems to be a promising treatment modality for patients with intermediate HCC. (orig.)

  15. Nano-Mole Scale Side-Chain Signal Assignment by 1H-Detected Protein Solid-State NMR by Ultra-Fast Magic-Angle Spinning and Stereo-Array Isotope Labeling

    KAUST Repository

    Wang, Songlin

    2015-04-09

    We present a general approach in 1H-detected 13C solid-state NMR (SSNMR) for side-chain signal assignments of 10-50 nmol quantities of proteins using a combination of a high magnetic field, ultra-fast magic-angle spinning (MAS) at ~80 kHz, and stereo-array-isotope-labeled (SAIL) proteins [Kainosho M. et al., Nature 440, 52–57, 2006]. First, we demonstrate that 1H indirect detection improves the sensitivity and resolution of 13C SSNMR of SAIL proteins for side-chain assignments in the ultra-fast MAS condition. 1H-detected SSNMR was performed for micro-crystalline ubiquitin (~55 nmol or ~0.5mg) that was SAIL-labeled at seven isoleucine (Ile) residues. Sensitivity was dramatically improved by 1H-detected 2D 1H/13C SSNMR by factors of 5.4-9.7 and 2.1-5.0, respectively, over 13C-detected 2D 1H/13C SSNMR and 1D 13C CPMAS, demonstrating that 2D 1H-detected SSNMR offers not only additional resolution but also sensitivity advantage over 1D 13C detection for the first time. High 1H resolution for the SAIL-labeled side-chain residues offered reasonable resolution even in the 2D data. A 1H-detected 3D 13C/13C/1H experiment on SAIL-ubiquitin provided nearly complete 1H and 13C assignments for seven Ile residues only within ~2.5 h. The results demonstrate the feasibility of side-chain signal assignment in this approach for as little as 10 nmol of a protein sample within ~3 days. The approach is likely applicable to a variety of proteins of biological interest without any requirements of highly efficient protein expression systems.

  16. Detection of activated platelets in a mouse model of carotid artery thrombosis with 18F-labeled single-chain antibodies

    International Nuclear Information System (INIS)

    Introduction: Activated platelets are key players in thrombosis and inflammation. We previously generated single-chain antibodies (scFv) against ligand-induced binding sites (LIBS) on the highly abundant platelet glycoprotein integrin receptor IIb/IIIa. The aim of this study was the construction and characterisation of a novel 18F PET radiotracer based on this antibody. Methods: ScFvanti-LIBS and control antibody mut-scFv were reacted with N-succinimidyl-4-[18F]fluorobenzoate (S[18F]FB). Radiolabeled scFv was incubated with in vitro formed platelet clots and injected into mice with FeCl3 induced thrombus in the left carotid artery. Clots were imaged in the PET scanner and amount of radioactivity measured using an ionization chamber and image analysis. Assessment of vessel injury as well as the biodistribution of the radiolabeled scFv was studied. Results: After incubation with increasing concentrations of 18F-scFvanti-LIBS clots had retained significantly higher amounts of radioactivity compared to clots incubated with radiolabeled 18F-mut-scFv (13.3 ± 3.8 vs. 3.6 ± 1 KBq, p < 0.05, n = 9, decay corrected). In the in vivo experiments we found an high uptake of the tracer in the injured vessel compared with the non-injured vessel, with 12.6 ± 4.7% injected dose per gram (ID/g) uptake in the injured vessel and 3.7 ± 0.9% ID/g in the non-injured vessel 5 minutes after injection (p < 0.05, n = 6). Conclusions: Our results show that the novel antibody radiotracer 18F-scFvanti-LIBS is useful for the sensitive detection of activated platelets and thrombosis. Advances in knowledge and implications for patient care: We describe the first 18F variant of a scFvanti-LIBS against activated platelets. This diagnostic agent could provide a powerful tool for the assessment of acute thrombosis and inflammation in patients in the future

  17. Arterial Ageing

    OpenAIRE

    Lee, Seung-Jun; Park, Sung-Ha

    2013-01-01

    Arterial ageing is characterized by age associated degeneration and sclerosis of the media layer of the large arteries. However, besides ageing, clinical conditions, which enhance oxidative stress and inflammation act to accelerate the degree of arterial ageing. In this review, we summarized the pathophysiology and contributing factors that accelerate arterial ageing. Among them, we focused on hypertension, the renin-angiotensin-aldosterone system and vascular inflammation which are modifiabl...

  18. Wasteful Labeling

    OpenAIRE

    Mahenc, Philippe

    2009-01-01

    The role of labeling is to solve the adverse selection problem caused by unsubstantiated claims from firms. The problem however is likely to remain unsolved if the labeling agency is not trustworthy.The agency can be suspected to divert the fees charged for labeling from their primary purpose of collecting information in order to raise excessive revenue. This paper addresses this issue and shows that labeling may be wasteful if the agency is likely to be untrustworthy. To award firms green la...

  19. Acute arterial occlusion - kidney

    Science.gov (United States)

    ... arterial thrombosis; Renal artery embolism; Acute renal artery occlusion; Embolism - renal artery ... often result in permanent kidney failure. Acute arterial occlusion of the renal artery can occur after injury ...

  20. Knot spinning

    OpenAIRE

    Friedman, Greg

    2004-01-01

    This is an introduction to the construction of higher-dimensional knots by spinning methods. Simple spinning of classical knots was introduced by E. Artin in 1926, and several generalizations have followed. These include twist spinning, superspinning or p-spinning, frame spinning, roll spinning, and deform spinning. We survey these constructions and some of their most important applications, as well as some newer hybrids due to the author. The exposition, meant to be accessible to a broad aud...

  1. Nutrition Labeling

    DEFF Research Database (Denmark)

    Grunert, Klaus G

    2013-01-01

    because consumers will avoid products that the label shows to be nutritionally deficient, but also because food producers will try to avoid marketing products that appear, according to the label, as nutritionally problematic, for example, because of a high content of saturated fat or salt. Nutrition......Nutrition labeling refers to the provision of information on a food product’s nutritional content on the package label. It can serve both public health and commercial purposes. From a public health perspective, the aim of nutrition labeling is to provide information that can enable consumers...... to make healthier choices when choosing food products. Nutrition labeling is thus closely linked to the notion of the informed consumer, that chooses products according to their aims, on the basis of the information at their disposal. Because many consumers are assumed to be interested in making healthy...

  2. Operator spin foam models

    Energy Technology Data Exchange (ETDEWEB)

    Bahr, Benjamin [DAMTP, Centre for Mathematical Sciences, Wilberforce Road, Cambridge CB3 0WA (United Kingdom); Hellmann, Frank; Kaminski, Wojciech; Kisielowski, Marcin; Lewandowski, Jerzy [Instytut Fizyki Teoretycznej, Uniwersytet Warszawski, ul. Hoza 69, 00-681 Warszawa (Warsaw), Polska. Poland (Poland)

    2011-05-21

    The goal of this paper is to introduce a systematic approach to spin foams. We define operator spin foams, that is foams labelled by group representations and operators, as our main tool. A set of moves we define in the set of the operator spin foams (among other operations) allows us to split the faces and the edges of the foams. We assign to each operator spin foam a contracted operator, by using the contractions at the vertices and suitably adjusted face amplitudes. The emergence of the face amplitudes is the consequence of assuming the invariance of the contracted operator with respect to the moves. Next, we define spin foam models and consider the class of models assumed to be symmetric with respect to the moves we have introduced, and assuming their partition functions (state sums) are defined by the contracted operators. Briefly speaking, those operator spin foam models are invariant with respect to the cellular decomposition, and are sensitive only to the topology and colouring of the foam. Imposing an extra symmetry leads to a family we call natural operator spin foam models. This symmetry, combined with assumed invariance with respect to the edge splitting move, determines a complete characterization of a general natural model. It can be obtained by applying arbitrary (quantum) constraints on an arbitrary BF spin foam model. In particular, imposing suitable constraints on a spin(4) BF spin foam model is exactly the way we tend to view 4D quantum gravity, starting with the BC model and continuing with the Engle-Pereira-Rovelli-Livine (EPRL) or Freidel-Krasnov (FK) models. That makes our framework directly applicable to those models. Specifically, our operator spin foam framework can be translated into the language of spin foams and partition functions. Among our natural spin foam models there are the BF spin foam model, the BC model, and a model corresponding to the EPRL intertwiners. Our operator spin foam framework can also be used for more general spin

  3. Nutrition Labeling

    Science.gov (United States)

    Metzger, Lloyd E.

    Nutrition labeling regulations differ in countries around the world. The focus of this chapter is on nutrition labeling regulations in the USA, as specified by the Food and Drug Administration (FDA) and the Food Safety and Inspection Service (FSIS) of the United States Department of Agriculture (USDA). A major reason for analyzing the chemical components of foods in the USA is nutrition labeling regulations. Nutrition label information is not only legally required in many countries, but also is of increasing importance to consumers as they focus more on health and wellness.

  4. Spin current

    CERN Document Server

    Valenzuela, Sergio O; Saitoh, Eiji; Kimura, Takashi

    2012-01-01

    In a new branch of physics and technology called spin-electronics or spintronics, the flow of electrical charge (usual current) as well as the flow of electron spin, the so-called 'spin current', are manipulated and controlled together. This book provides an introduction and guide to the new physics and application of spin current.

  5. Spin supercurrent

    International Nuclear Information System (INIS)

    We review the main properties of spin waves condensation to a coherent quantum state, named homogeneously precessing domain (HPD). We describe the long range coherent transport of magnetization by spin supercurrent in antiferromagnetic superfluid He3. This quantum phenomenon was discovered 20 years ago. Since then, many magnetic extensions of superconductivity and superfluidity have been observed: spin Josephson phenomena, spin-current vortices, spin phase slippage, long distance magnetization transport by spin supercurrents, etc. Several new supercurrent phenomena have been discovered, like magnetically excited coherent quantum states, NMR in the molecular Landau field, spin-current turbulence, formation of stable non-topological solitons, etc

  6. Tensorial Spin-s Harmonics

    OpenAIRE

    Newman, Ezra T.; Silva-Ortigoza, Gilberto

    2005-01-01

    We show how to define and go from the spin-s spherical harmonics to the tensorial spin-s harmonics. These quantities, which are functions on the sphere taking values as Euclidean tensors, turn out to be extremely useful for many calculations in General Relativity. In the calculations, products of these functions, with their needed decompositions which are given here, often arise naturally.

  7. MR imaging of persistent primitive trigeminal artery

    Energy Technology Data Exchange (ETDEWEB)

    Ashikaga, Ryuichiro; Araki, Yutaka; Ono, Yukihiko; Ishida, Osamu [Kinki Univ., Higashi-Osaka, Osaka (Japan); Mabuchi, Nobuhisa

    1997-02-01

    The persistent trigeminal artery is the most common anomaly of the primitive carotid-vertebrobasilar anastomoses. We reviewed MR images and MR angiographies of 11 patients with primitive trigeminal artery. In 8 of the 11 cases, PTA were identified with conventional long TR spin-echo images. In 8 of 11 cases, a hypoplastic basilar trunk associated with PTA was seen on both MR images and MR angiographies. In 7 of 11 cases, a hypoplasia or agenesis of the ipsilateral posterior communicating artery was seen on MR angiographies. (author)

  8. MR imaging of persistent primitive trigeminal artery

    International Nuclear Information System (INIS)

    The persistent trigeminal artery is the most common anomaly of the primitive carotid-vertebrobasilar anastomoses. We reviewed MR images and MR angiographies of 11 patients with primitive trigeminal artery. In 8 of the 11 cases, PTA were identified with conventional long TR spin-echo images. In 8 of 11 cases, a hypoplastic basilar trunk associated with PTA was seen on both MR images and MR angiographies. In 7 of 11 cases, a hypoplasia or agenesis of the ipsilateral posterior communicating artery was seen on MR angiographies. (author)

  9. Carotid Artery Screening

    Science.gov (United States)

    ... Resources Professions Site Index A-Z Carotid Artery Screening What is carotid artery screening? Who should consider ... about carotid artery screening? What is carotid artery screening? Screening examinations are tests performed to find disease ...

  10. Automatic segmentation method which divides a cerebral artery tree in time-of-flight MR-angiography into artery segments

    Science.gov (United States)

    Takemura, Akihiro; Suzuki, Masayuki; Harauchi, Hajime; Okumura, Yusuke; Umeda, Tokuo

    2006-03-01

    To achieve sufficient accuracy and robustness, 2D/3D registration methods between DSA and MRA of the cerebral artery require an automatic extraction method that can isolate wanted segments from the cerebral artery tree. Here, we described an automatic segmentation method that divides the cerebral artery tree in time-of-flight magnetic resonance angiography (TOF-MRA) into each artery. This method requires a 3D dataset of the cerebral artery tree obtained by TOF-MRA. The processes of this method are: 1) every branch in the cerebral artery tree is labeled with a unique index number, 2) the 3D center of the Circle of Willis is determined using 2D and 3D templates, and 3) the labeled branches are classified with reference to the 3D territory map of cerebral arteries centered on the Circle of Willis. This method classifies all branches into internal carotid arteries (ICA), basilar artery (BA), middle cerebral artery (MCA), a1 segment of anterior cerebral artery (ACA(A1)), other segments of the anterior cerebral artery (ACA), posterior communication artery (PcomA), and posterior cerebral artery (PCA). In the eleven cases examined, the numbers of correctly segmented pixels in each branch were counted and the percentages based on the total number of pixels of the artery were calculated. Manually classified arteries of each case were used as references. Mean percentages were: ACA, 87.6%; R-ACA(A1), 44.9%; L-ACA(A1), 30.4%; R-MC, 82.4%; L-MC, 79.0%; R-PcomA, 0.5%; L-PcomA, 0.0%; R-PCA, 77.2%; L-PCA, 80.0%; R-ICA, 78.6%; L-ICA, 93.05; BA, 77.1%; and total arteries, 78.9%.

  11. Food labels

    DEFF Research Database (Denmark)

    Selsøe Sørensen, Henrik; Clement, Jesper; Gabrielsen, Gorm

    2012-01-01

    The food industry develops tasty and healthy food but fails to deliver the message to all consumers. The consumers’ background knowledge is essential for how they find and decode relevant elements in the cocktail of signs which fight for attention on food labels. In this exploratory study, we find...... evidence for dividing consumers into two profiles: one relying on general food knowledge and another using knowledge related to signpost labels. In a combined eyetracking and questionnaire survey we analyse the influence of background knowledge and identify different patterns of visual attention for the...... two consumer profiles. This underlines the complexity in choosing and designing the ‘right’ elements for a food package that consumers actually look at and are able to make rational use of. In spite of any regulation of food information provided by authorities, consumers will still be confronted with...

  12. Environmental Labeling

    OpenAIRE

    Andrea Podhorsky

    2009-01-01

    This paper studies how information disclosed by voluntary environmental labels creates incentives for firms to invest in environmentally-friendly production technologies. I develop a model with differentiated products and imperfectly-informed consumers. Consumers care about the environmental characteristics of goods (for example, how they were produced), but cannot directly observe these product characteristics. Firms differ in their abilities to develop "clean" technologies, but have no ince...

  13. In vivo quantification of hyperoxic arterial blood water T1.

    Science.gov (United States)

    Siero, Jeroen C W; Strother, Megan K; Faraco, Carlos C; Hoogduin, Hans; Hendrikse, Jeroen; Donahue, Manus J

    2015-11-01

    Normocapnic hyperoxic and hypercapnic hyperoxic gas challenges are increasingly being used in cerebrovascular reactivity (CVR) and calibrated functional MRI experiments. The longitudinal arterial blood water relaxation time (T1a) change with hyperoxia will influence signal quantification through mechanisms relating to elevated partial pressure of plasma-dissolved O2 (pO2) and increased oxygen bound to hemoglobin in arteries (Ya) and veins (Yv). The dependence of T1a on Ya and Yv has been elegantly characterized ex vivo; however, the combined influence of pO2, Ya and Yv on T1a in vivo under normal ventilation has not been reported. Here, T1a is calculated during hyperoxia in vivo by a heuristic approach that evaluates T1 -dependent arterial spin labeling (ASL) signal changes to varying gas stimuli. Healthy volunteers (n = 14; age, 31.5 ± 7.2 years) were scanned using pseudo-continuous ASL in combination with room air (RA; 21% O2/79% N2), hypercapnic normoxic (HN; 5% CO2/21% O2/74% N2) and hypercapnic hyperoxic (HH; 5% CO2/95% O2) gas administration. HH T1a was calculated by requiring that the HN and HH cerebral blood flow (CBF) change be identical. The HH protocol was then repeated in patients (n = 10; age, 61.4 ± 13.3 years) with intracranial stenosis to assess whether an HH T1a decrease prohibited ASL from being performed in subjects with known delayed blood arrival times. Arterial blood T1a decreased from 1.65 s at baseline to 1.49 ± 0.07 s during HH. In patients, CBF values in the affected flow territory for the HH condition were increased relative to baseline CBF values and were within the physiological range (RA CBF = 36.6 ± 8.2 mL/100 g/min; HH CBF = 45.2 ± 13.9 mL/100 g/min). It can be concluded that hyperoxic (95% O2) 3-T arterial blood T1aHH = 1.49 ± 0.07 s relative to a normoxic T1a of 1.65 s. PMID:26419505

  14. Application of interictal arterial spin labeling MR perfusion in intractable mesial temporal lobe epilepsy%动脉自旋标记在难治性颞叶内侧癫痫发作间期的应用

    Institute of Scientific and Technical Information of China (English)

    孙泓泓; 吕长磊; 白芝兰; 张晓娜; 师莉芳

    2012-01-01

    Objective To determine whether pulsed ASL(PASL) MR] using flow-sensitive alternating inversion recovery) FAIR) could be a useful clinical tool to detect intcrictal temporal hypopcrfusion in mesial temporal lobe cpilcpsy(TLEl) ,thcn on the base of changes of cerebral blood flow(CBF) to determine the seizure focus. Methods 15 normal controls and 15 patients were studied by using a FAIR pcrfusion mode to measure the CBF of mesial temporal lobe. According to the vidco-clcctrocnccphalography ( VEEG) findings, the origin sides of seizure were obtained in all patients. Results Pcrfusion in control participants was ( 167. 95 ± 15. 30) mL/( 100 g · min) on the right and (169.64 ± 13.24) mL/( 100 g · min) on the left. In patients, mesial temporal lobe pcrfusion was (158.42 ± 9.09) mL/(100 g- min) on the ipsilatcral (affected) side and (170. 11±7. 67) mL/(100 g · min) on the contralatcral (unaffected) side. The blood flow measurements were significantly different in ipsilatcral versus contralatcral sides in patients. In control participants, the mean absolute asymmetry index was 2. 49 ± 2. 09. For the patients, mean absolute asymmetry index was 7. 20 ± 4. 21. The difference was statistically significant P = 0. 001 ). The coefficient of agreement for detecting the asymmetry with FAIR and with vidco-EEG latcralization was 80%. Conclusion MR pcrfusion imaging based on the FAIR technique is capable of detecting intcrictal hypopcrfusion of mesial temporal lobe in patients with medically refractory temporal lobe epilepsy and provides complementary information to tests that assess structure.%目的 明确流动敏感交互反转恢复模式(FAIR)的脉冲式动脉自旋标记(PASL)能否检测出发作间期颞叶内侧的低灌注,根据脑血流灌注变化确定致痫灶位置.方法 15例经过视频脑电图(VEEG)确诊的颞叶癫痫(TLE)病人和15例正常对照者行FAIR测量感兴趣区脑血流量(CBF)并计算相关数值.结果 对照组左、右颞叶内侧灌注分别是(169.64±13.24) mL/(100 g·min)、(167.95±15.30) mL/(100 g·min).病例组致痫灶同侧与对侧颞叶内侧灌注分别是(158.42±9.09) mL/(100 g·min)、(170.11±7.67) mL/(100 g·min),两侧颞叶内侧血流量明显不同.对照组和病例组颞叶内侧灌注的不对称指数分别为2.49±2.09、7.20±4.21.虽然对照组颞叶内侧CBF也存在不对称性,病例组颞叶内侧CBF不对称指数(AI)明显大于对照组,AI差别存在统计学差异(P=0.001).FAIR和VEEG对致痫灶定侧一致率达80%.结论 FAIR 灌注成像可以检测出难治性TLE病人发作间期颞叶内侧CBF灌注减低,是对结构评估的有益补充.

  15. Progresses of arterial spin labeling MRI in mesial temporal lobe epilepsy%动脉自旋标记技术在内侧颞叶癫痫中的应用进展

    Institute of Scientific and Technical Information of China (English)

    郭小琴; 赵斌; 王光彬

    2014-01-01

    内侧颞叶癫痫(MTLE)为致痫灶起源于内侧颞叶并可伴有海马硬化的一类癫痫,随着新技术的开发与应用,影像学检查在改善其临床诊断与治疗中发挥着越来越大的作用.动脉自旋标记(ASL)是一种无创的MR成像技术.本文对ASL在MTLE相关基础研究与临床应用中的进展进行综述.

  16. Spinning superparticle

    International Nuclear Information System (INIS)

    A new theory of relativistic particle which has properties of spinning particle and superparticle simultaneously is proposed. The action for a relativistic spinless and massless particle is discussed. The spinning superparticle is considered in Lagrangian formalism and hamiltonian for it is constracted. Conclusion is made that the obtained result may be generalized for the theory of fermionic string. 11 refs

  17. Spin glasses

    CERN Document Server

    Bovier, Anton

    2007-01-01

    Spin glass theory is going through a stunning period of progress while finding exciting new applications in areas beyond theoretical physics, in particular in combinatorics and computer science. This collection of state-of-the-art review papers written by leading experts in the field covers the topic from a wide variety of angles. The topics covered are mean field spin glasses, including a pedagogical account of Talagrand's proof of the Parisi solution, short range spin glasses, emphasizing the open problem of the relevance of the mean-field theory for lattice models, and the dynamics of spin glasses, in particular the problem of ageing in mean field models. The book will serve as a concise introduction to the state of the art of spin glass theory, usefull to both graduate students and young researchers, as well as to anyone curious to know what is going on in this exciting area of mathematical physics.

  18. Carotid Artery Disease

    Science.gov (United States)

    ... brain with blood. If you have carotid artery disease, the arteries become narrow, usually because of atherosclerosis. ... one of the causes of stroke. Carotid artery disease often does not cause symptoms, but there are ...

  19. Mesenteric artery ischemia

    Science.gov (United States)

    Mesenteric artery ischemia occurs when there is a narrowing or blockage of one or more of the three major arteries that ... that supply blood to the intestine causes mesenteric ischemia. The arteries that supply blood to the intestines ...

  20. Spin electronics

    CERN Document Server

    Buhrman, Robert; Daughton, James; Molnár, Stephan; Roukes, Michael

    2004-01-01

    This report is a comparative review of spin electronics ("spintronics") research and development activities in the United States, Japan, and Western Europe conducted by a panel of leading U.S. experts in the field. It covers materials, fabrication and characterization of magnetic nanostructures, magnetism and spin control in magnetic nanostructures, magneto-optical properties of semiconductors, and magnetoelectronics and devices. The panel's conclusions are based on a literature review and a series of site visits to leading spin electronics research centers in Japan and Western Europe. The panel found that Japan is clearly the world leader in new material synthesis and characterization; it is also a leader in magneto-optical properties of semiconductor devices. Europe is strong in theory pertaining to spin electronics, including injection device structures such as tunneling devices, and band structure predictions of materials properties, and in development of magnetic semiconductors and semiconductor heterost...

  1. Ivabradine: A Review of Labeled and Off-Label Uses.

    Science.gov (United States)

    Oliphant, Carrie S; Owens, Ryan E; Bolorunduro, Oluwaseyi B; Jha, Sunil K

    2016-10-01

    Ivabradine is a unique medication recently approved in the USA for the treatment of select heart failure patients. It was first approved for use in several countries around the world over a decade ago as an anti-anginal agent, with subsequent approval for use in heart failure patients. Since ivabradine has selective activity blocking the I f currents in the sinus node, it can reduce heart rate without appreciable effects on blood pressure. Given this heart-rate-specific effect, it has been investigated in many off-label indications as an alternative to traditional heart-rate-reducing medications such as beta blockers and calcium channel blockers. We conducted searches of PubMed and Google Scholar for ivabradine, heart failure, HFrEF, HFpEF, angina, coronary artery disease, inappropriate sinus tachycardia, postural orthostatic hypotension, coronary computed tomography angiography and atrial fibrillation. We reviewed and included studies, case reports, and case series published between 1980 and June 2016 if they provided information relevant to the practicing clinician. In many cases, larger clinical trials are needed to solidify the benefit of ivabradine, although studies indicate benefit in most therapeutic areas explored to date. The purpose of this paper is to review the current labeled and off-label uses of ivabradine, with a focus on clinical trial data. PMID:27405864

  2. Spin-Orbit induced semiconductor spin guides

    OpenAIRE

    Valin-Rodriguez, Manuel; Puente, Antonio; Serra, Llorens

    2002-01-01

    The tunability of the Rashba spin-orbit coupling allows to build semiconductor heterostructures with space modulated coupling intensities. We show that a wire-shaped spin-orbit modulation in a quantum well can support propagating electronic states inside the wire only for a certain spin orientation and, therefore, it acts as an effective spin transmission guide for this particular spin orientation.

  3. Issues in Data Labelling

    NARCIS (Netherlands)

    Cowie, Roddy; Cox, Cate; Martin, Jeam-Claude; Batliner, Anton; Heylen, Dirk; Karpouzis, Kostas; Cowie, Roddy; Pelachaud, Catherine; Petta, Paolo

    2011-01-01

    Labelling emotion databases is not a purely technical matter. It is bound up with theoretical issues. Different issues affect labelling of emotional content, labelling of the signs that convey emotion, and labelling of the relevant context. Linked to these are representational issues, involving time

  4. Open Spin Chain and Open Spinning String

    OpenAIRE

    CHEN Bin; Wang, Xiao-Jun; Wu, Yong-Shi

    2004-01-01

    In this letter, we study the open spinning strings and their SYM duals. A new class of folded open spinning strings is found. At planar one-loop level in SYM, by solving the thermodynamic limit of the Bethe ansatz equations for an integrable open spin chain, we find good agreement with string theory predictions for energies of both circular and folded two-spin solutions. A universal relation between the open and closed spinning strings is verified in the spin chain approach.

  5. Interference Spins

    DEFF Research Database (Denmark)

    Popovski, Petar; Simeone, Osvaldo; Nielsen, Jimmy Jessen;

    2015-01-01

    traffic load and interference condition leads to performance gains. In this letter, a general network of multiple interfering two-way links is studied under the assumption of a balanced load in the two directions for each link. Using the notion of interference spin, we introduce an algebraic framework for...

  6. Electron spin resonance studies on reduction process of nitroxyl spin radicals used in molecular imaging

    International Nuclear Information System (INIS)

    The Electron spin resonance studies on the reduction process of nitroxyl spin probes were carried out for 1mM 14N labeled nitroxyl radicals in pure water and 1 mM concentration of ascorbic acid as a function of time. The electron spin resonance parameters such as signal intensity ratio, line width, g-value, hyperfine coupling constant and rotational correlation time were determined. The half life time was estimated for 1mM 14N labeled nitroxyl radicals in 1 mM concentration of ascorbic acid. The ESR study reveals that the TEMPONE has narrowest line width and fast tumbling motion compared with TEMPO and TEMPOL. From the results, TEMPONE has long half life time and high stability compared with TEMPO and TEMPOL radical. Therefore, this study reveals that the TEMPONE radical can act as a good redox sensitive spin probe for molecular imaging

  7. Using Markov models to simulate electron spin resonance spectra from molecular dynamics trajectories

    OpenAIRE

    Sezer, Deniz; Freed, Jack H.; Roux, Benoît

    2008-01-01

    Simulating electron spin resonance (ESR) spectra directly from molecular dynamics simulations of a spin labeled protein necessitates a large number (hundreds or thousands) of relatively long (hundreds of ns) trajectories. To meet this challenge, we explore the possibility of constructing accurate stochastic models of the spin label dynamics from atomistic trajectories. A systematic, two-step procedure, based on the probabilistic framework of hidden Markov models, is developed to build a discr...

  8. Succesful labelling schemes

    DEFF Research Database (Denmark)

    Juhl, Hans Jørn; Stacey, Julia

    2001-01-01

    It is usual practice to evaluate the success of a labelling scheme by looking at the awareness percentage, but in many cases this is not sufficient. The awareness percentage gives no indication of which of the consumer segments that are aware of and use labelling schemes and which do not. In the...... spring of 2001 MAPP carried out an extensive consumer study with special emphasis on the Nordic environmentally friendly label 'the swan'. The purpose was to find out how much consumers actually know and use various labelling schemes. 869 households were contacted and asked to fill in a questionnaire....... 664 households returned a completed questionnaire. There were five answering categories for each label in the questionnaire: * have not seen the label before. * I have seen the label before but I do not know the precise contents of the labelling scheme. * I have seen the label before, I do not know...

  9. Occlusive Peripheral Arterial Disease

    Science.gov (United States)

    ... erythrocyte sedimentation rate (ESR) and level of C-reactive protein, which is produced only when inflammation is present. ... people with occlusive peripheral arterial disease also have coronary artery disease. Amputation of a limb may be necessary if ...

  10. Synthesizing labeled compounds

    International Nuclear Information System (INIS)

    A metabolic study is presented of the chemical reactions provided by isotopic labeling and NMR spectroscopy. Synthesis of 13C-labeled D-glucose, a 6-carbon sugar, involves adding a labeled nitrile group to the 5-carbon sugar D-arabinose by reaction with labeled hydrogen cyanide. The product of this reaction is then reduced and hydrolyzed to a mixture of the labeled sugars. The two sugars are separated by absorption chromotography. The synthesis of 13C-labeled L-tyrosine, an amino acid, is also presented

  11. Combination of Rare Right Arterial Variation with Anomalous Origins of the Vertebral Artery, Aberrant Subclavian Artery and Persistent Trigeminal Artery

    Science.gov (United States)

    Ishihara, H.; San Millán Ruíz, D.; Abdo, G.; Asakura, F.; Yilmaz, H.; Lovblad, K.O.; Rüfenacht, D.A.

    2011-01-01

    Summary A 32-year-old woman hospitalized for subarachnoid hemorrhage showed rare arterial variation on the right side with anomalous origins of the vertebral artery, aberrant subclavian artery and persistent trigeminal artery. Angiography showed the right vertebral artery to originate from the right common carotid artery, the right subclavian artery to arise separately from the descending aorta, and persistent trigeminal artery on the right side. The possible embryonic mechanism of this previously unreported variant combination is discussed. PMID:22005696

  12. On Renal Artery Stenosis

    OpenAIRE

    Eklöf, Hampus

    2005-01-01

    Renal artery stenosis (RAS) is a potentially curable cause of hypertension and azotemia. Besides intra-arterial renal angiography there are several non-invasive techniques utilized to diagnose patients with suspicion of renal artery stenosis. Removing the stenosis by revascularization to restore unobstructed blood flow to the kidney is known to improve and even cure hypertension/azotemia, but is associated with a significant complication rate. To visualize renal arteries with x-ray technique...

  13. Peripheral Artery Disease

    Science.gov (United States)

    ... or atherectomy may be used to help improve blood flow. What is peripheral artery disease (PAD)? How is peripheral artery disease evaluated? How ... PAD are diabetes, smoking, high cholesterol and high blood pressure. Most cases occur in ... is peripheral artery disease evaluated? Several imaging tests can be used to ...

  14. Retinal artery occlusion

    Science.gov (United States)

    ... artery occlusion; Branch retinal artery occlusion; CRAO; BRAO Images Retina References Sanborn GE, Magargal LE. Arterial obstructive disease ... A.M. Editorial team. Related MedlinePlus Health Topics ... audit to verify that A.D.A.M. follows rigorous standards of quality and accountability. A.D.A.M. is among ...

  15. In vitro model of platelet aggregation in stenotic arteries

    International Nuclear Information System (INIS)

    Clinical and experimental evidence suggest a strong relationship between arterial stenosis, platelet aggregation, and subsequent thrombus formation. To facilitate the study of platelet accumulation in stenotic arteries, we developed an in vitro preparation. Arterial segments were perfused with whole citrated blood. A stenosis was created by applying an external plastic constrictor to the artery. Platelet accumulation within the stenosis was assessed by scanning electron microscopy and by radioactive counts from Indium-111 labeled platelets. Utilizing this preparation, 30 carotid arterial segments from 10 mongrel dogs were perfused at 100 mmHg for 15 min. In 10 arteries without a stenosis, scanning electron microscopy and radioactive counts demonstrated little platelet accumulation. In contrast, extensive platelet aggregation was observed in 10 arteries with stenoses. Moreover, in 10 stenotic arteries exposed to the thromboxane mimetic, U46619 (Upjohn Diagnostic Group), scanning electron microscopy and radioactive counts demonstrated a significant increase in platelet deposition. Conversely, we demonstrated a dimunition of platelet accumulation in stenosed arterial segments exposed to the prostacyclin analogue platelet inhibitor, Iloprost. The in vitro preparation allows precise control of hemodynamic variables and makes it possible to perform multiple tests on segments of the same vessel from the same animal

  16. The efficacy and safety of bosentan therapy for Chinese patients with idiopathic pulmonary arterial hypertension:an open-label, prospective multicenter study%波生坦治疗特发性肺动脉高压患者的疗效及安全性

    Institute of Scientific and Technical Information of China (English)

    代立志; 蒋鑫; 王勇; 余再新; 姚桦; 王广义; 吴炳祥; 荆志成

    2011-01-01

    Objective To investigate the efficacy, safety and tolerance of bosentan, a dual endothelin receptor antagonist, in Chinese patients with idiopathic pulmonary arterial hypertension (IPAH).Methods Totally 79 IPAH patients (hemodynamic criteria confirmed by right heart catheterization) were included in this open-label, prospective multicenter study. Patients received 62. 5 mg of bosentan twice daily for the first 4 weeks, and then up-titrated to 125 mg twice daily for another 12 weeks. The primary end point was the change in exercise capacity showed by six-minute walk distance (6MWD) from baseline to 16 weeks. Secondary end points included the change in World Health Organization (WHO) functional class,Borg dyspnoea scale and systolic pulmonary artery pressure measured by echocardiography. Results The 6MWD increased from (343. 7 ± 93.7) meters at baseline to (397.5 ± 104. 4) meters after 16 weeks ( P <0. 01 ), WHO functional class and Borg dyspnoea scale were also significantly improved after 16 weeks therapy compared to baseline levels (all P <0. 01 ). Furthermore, the systolic pulmonary artery pressure was significantly decreased from (97.8±25.2) mm Hg (1 mm Hg=0. 133 kPa) to (92.8 ±29.5) mm Hg (P <0. 05) after 16 weeks bosentan treatment. There was no patient withdrawal from this study for safety consideration. Conclusion Bosentan therapy is well tolerated and can improve the exercise capacity and WHO functional class in Chinese IPAH patients.%目的 观察内皮素受体拮抗剂波生坦治疗中国特发性肺动脉高压患者的有效性、安全性及耐受性.方法 全国多中心Ⅳ期临床试验,共入选79例右心导管等技术确诊的新发特发性肺动脉高压患者,口服波生坦每日2次,每次62.5 mg,治疗4周后增至每日2次,每次125 mg至16周试验结束.分别在基线及治疗16周时记录6分钟步行距离,WHO肺高压功能分级、Borg呼吸困难评分及超声心动图评价资料.结果 波生坦治疗16

  17. Mental Labels and Tattoos

    Science.gov (United States)

    Hyatt, I. Ralph

    1977-01-01

    Discusses the ease with which mental labels become imprinted in our system, six basic axioms for maintaining negative mental tattoos, and psychological processes for eliminating mental tattoos and labels. (RK)

  18. Pesticide Product Label System

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Pesticide Product Label System (PPLS) provides a collection of pesticide product labels (Adobe PDF format) that have been approved by EPA under Section 3 of the...

  19. Detection of pulmonary hemorrhage with technetium-labeled red cells

    Energy Technology Data Exchange (ETDEWEB)

    Winzelberg, G.G.; Laman, D.; Sachs, M.; Miller, W.H.

    1981-10-01

    Noninvasive techniques to aid in the diagnosis of massive pulmonary hemoptysis would be helpful in guiding more-invasive procedures such as bronchial artery angiography, which carries a risk of transverse myelitis. A patient was studied with technetium-labeled red cells and successfully detected a site of intermittent hemorrhage from the lung.

  20. Detection of pulmonary hemorrhage with technetium-labeled red cells

    International Nuclear Information System (INIS)

    Noninvasive techniques to aid in the diagnosis of massive pulmonary hemoptysis would be helpful in guiding more-invasive procedures such as bronchial artery angiography, which carries a risk of transverse myelitis. A patient was studied with technetium-labeled red cells and successfully detected a site of intermittent hemorrhage from the lung

  1. On Online Labeling with Polynomially Many Labels

    DEFF Research Database (Denmark)

    Babka, Martin; Bulánek, Jan; Cunat, Vladimír; Koucky, Michal; Saks, Michael

    2012-01-01

    In the online labeling problem with parameters n and m we are presented with a sequence of nkeys from a totally ordered universe U and must assign each arriving key a label from the label set {1,2,…,m} so that the order of labels (strictly) respects the ordering on U. As new keys arrive it may be...... necessary to change the labels of some items; such changes may be done at any time at unit cost for each change. The goal is to minimize the total cost. An alternative formulation of this problem is the file maintenance problem, in which the items, instead of being labeled, are maintained in sorted order in...... are known that use O(n logn) relabelings. A matching lower bound was claimed in [7]. That proof involved two distinct steps: a lower bound for a problem they call prefix bucketing and a reduction from prefix bucketing to online labeling. The reduction seems to be incorrect, leaving a (seemingly...

  2. Duplication of hepatic artery

    Directory of Open Access Journals (Sweden)

    Saeed Muhammad

    2001-01-01

    Full Text Available Background: The hepatic arterial anatomy is aberrant in almost 33-41% of individuals. The variant arterial anatomy recognized during routine cadaveric dissection offers great learning potential. Such findings provide an alternative perspective to view common morphology and its structural and functional importance. These impart the concept of patient individuality and subsequent individualization of medical and surgical therapies. Adequate knowledge of normal and abnormal arterial anatomy is essential for peripancreatic surgery and liver transplantation. Aims of the study: To report on hepatic artery variations observed in the dissecting room and to find out the macroscopic pattern of varied human hepatic arterial vascularization by cadaveric dissection. Patients and Methods: Twenty human cadavers of caucasian origin were dissected to study the source and topographic pattern of hepatic arterial supply. Results: Nineteen cadavers exhibited typical hepatic arterial supply from the celiac axis. Only one female body out of twenty cadavers exhibited a dual arterial supply to all parts of liver and gallbladder. One artery originated from the celiac axis whereas the other was given off by the superior mesenteric artery. Conclusion: No doubt, aberrant hepatic vascularization should be assessed preoperatively by invasive and noninvasive techniques to avoid fatal complications, but we favour careful dissection over angiography as a means of defining the arterial anatomy.

  3. Acute occlusion of the left subclavian artery with artery dissection

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ Subclavian steal syndrome is cerebral or brain stem ischemia resulting from diversion of blood flow from the basilar artery to the subclavian artery, which is caused by occlusive disease of either the subclavian artery or the innominate artery before they branch off at the vertebral artery. In the patients with subclavian steal syndrome the subclavian artery is fed by retrograde flow from the vertebral artery via the carotids and the circle of Willis.

  4. Spin injection into semiconductors

    Science.gov (United States)

    Oestreich, M.; Hübner, J.; Hägele, D.; Klar, P. J.; Heimbrodt, W.; Rühle, W. W.; Ashenford, D. E.; Lunn, B.

    1999-03-01

    The injection of spin-polarized electrons is presently one of the major challenges in semiconductor spin electronics. We propose and demonstrate a most efficient spin injection using diluted magnetic semiconductors as spin aligners. Time-resolved photoluminescence with a Cd0.98Mn0.02Te/CdTe structure proves the feasibility of the spin-alignment mechanism.

  5. Screening asymptomatic patients with diabetes for unknown coronary artery disease: Does it reduce risk? An open-label randomized trial comparing a strategy based on exercise testing aimed at revascularization with management based on pharmacological/behavioural treatment of traditional risk factors. DADDY-D Trial (Does coronary Atherosclerosis Deserve to be Diagnosed and treated early in Diabetics?)

    OpenAIRE

    Romano Stefania; Pellegrini Elisa; Cappelli Carlo; Tosoni Giandomenico; Cavani Rita; Magnavacchi Paolo; Tondi Stefano; Giovanardi Paolo; Messora Roberto; Turrini Fabrizio; Baldini Augusto; Zennaro Romeo; Bondi Marco

    2009-01-01

    Abstract Background Coronary artery disease is the leading cause of morbidity and mortality in patients with type 2 diabetes. Screening for asymptomatic coronary artery disease with treatment by means of revascularization seems to be an appealing option for prevention. The utility of such a strategy has never been challenged in a randomized trial. Methods/Design In the present study a cohort of diabetic patients without any symptoms and without known coronary artery disease will be screened a...

  6. Spin noise in mixed Spin Systems

    Science.gov (United States)

    Bauch, Erik; Junghyun, Paul; Singh, Swati; Devakul, Trithep; Feguin, Adrian; Hart, Connor; Walsworth, Ronald

    2016-05-01

    The spin noise due to interaction of multiple spin species in mixed spin systems provides a fundamental limit to ultra-sensitive ensemble sensing and quantum information applications. In our work, we investigate the interaction of dense nuclear 13C spins with electronic nitrogen spins using Nitrogen-Vacancy centers in diamond. Our work shows experimentally and theoretically, that under certain conditions, spin noise is greatly suppressed and the coherence time of NV centers improved by order of magnitudes, providing a pathway to engineering high density ensemble samples with long coherence times at room temperature.

  7. In vitro and in vivo MR imaging of SHU 555A-labelled swine bone marrow mesenchymal stem cells

    International Nuclear Information System (INIS)

    Objective: To detect the feasibility of magnetically labeled swine bone marrow mesenchymal stem cells (MSCs) with SHU 555A combined with poly-L-arginine (PLL), under MR imaging in vitro and in vivo. Methods: Swine mesenchymal stem cells were isolated and culture-expanded 3 passages in vitro, then magnetically labeled by incubation with SHU 555A (25 μg Fe/ml, Resovist, Schering)for 24 hours with 750 ng/mL poly-L-lysine (PLL; average MW275 kDa) added 1 hour before incubation. Cellular iron incorporation and detention at 0 d, 4 d, 8 d, 12 d, 16 d, 20 d after labeling was qualitatively assessed using Prussian blue and quantified at atomic absorption spectrometry. Cell viability was assessed by trypan-blue exclusion test. Cell suspensions underwent MR imaging with T1-and T2-weighted spin-echo and fast field-echo sequences on a clinical 1.5 T MR system. At last, 1 x 106 SHU 555A labeled and unlabeled MSCs were transextracardially implanted into the infracted and normal myocardium approximately 2 week following the ligation of left anterior descending coronary artery in 1 swine respectively, and finally performed 1.5-T MRI within 1 week after infarction. Results: (1) Intracytoplasmic particles stained with Prussian blue stain were detected for all cells with mean cellular iron content of (13.13±2.30) pg per cell. With division of stem cells, the stained particles decreased gradually with iron content (0.68±0.20) pg per cell.at 16 days after labeling, approximately to the prelabeled baseline values. (0.21±0.06) pg per cell (P>0.05). The viability of the labeled cells at various time points were not significantly different with that of nonlabeled cells (P>0.05). (2) MR images showed signal intensity changed most obviouly in T2*WI in vitro. The percentage change of signal intensity increased with increasing cell numbers, and decreased with the time. As few as 5 x 104 - 1 x l05 cells could be detected by using this approach. (3)Two injected sites containing MR-MSCs were

  8. Labelling by deuteration and nitroxide radicals of mono-, oligo- and polysaccharides (cellulose and amylose)

    International Nuclear Information System (INIS)

    The application of NMR and deuteration labelling to the investigation of polysaccharides has led to considerable progress in recent years in the knowledge of these compounds. Although far more recent, the introduction of spin labelling techniques in the investigation of polymers, has given rise to interesting EPR studies of synthetic and natural macromolecules, but nothing appears to have been accomplished in the area of spin labelling of polysaccharides. This work was aimed at applying these two techniques to the study of glucose derivatives and of some of its oligomers (low molecular weight polymers): cellobiose, maltose and cyclodextrins; and its polymers: cellulose and amylose. Irrespective of the technique employed, the complexity of the polymers and problems connected with handling them always require the same procedure: an initial study of a model compound generally prepared from the monomer or an oligomer (dimer), followed by the oligomers, and finally the polymer. Part 1 is devoted to the deuteration labelling of mono- and oligosaccharides. Part 2 concerns spin labelling of cellulose acetate. In part 3, an attempt is made to apply the spin labelling technique to the determination of conformations of two disaccharides of different glycosidic configurations: cellobiose and maltose. Part 4 is devoted to spin and deuteration labelling of α and β cyclodextrins

  9. Relativistic Spin Operators

    Institute of Scientific and Technical Information of China (English)

    ZHANG Peng-Fei; RUAN Tu-Nan

    2001-01-01

    A systematic theory on the appropriate spin operators for the relativistic states is developed. For a massive relativistic particle with arbitrary nonzero spin, the spin operator should be replaced with the relativistic one, which is called in this paper as moving spin. Further the concept of moving spin is discussed in the quantum field theory. A new is constructed. It is shown that, in virtue of the two operators, problems in quantum field concerned spin can be neatly settled.

  10. Spin liquids in graphene

    OpenAIRE

    Tran, Minh-Tien; Kim, Ki-Seok

    2010-01-01

    We reveal that local interactions in graphene allow novel spin liquids between the semi-metal and antiferromagnetic Mott insulating phases, identified with algebraic spin liquid and Z$_{2}$ spin liquid, respectively. We argue that the algebraic spin liquid can be regarded as the two dimensional realization of one dimensional spin dynamics, where antiferromagnetic correlations show exactly the same power-law dependence as valence bond correlations. Nature of the Z$_{2}$ spin liquid turns out t...

  11. Automatic classification of retinal vessels into arteries and veins

    Science.gov (United States)

    Niemeijer, Meindert; van Ginneken, Bram; Abràmoff, Michael D.

    2009-02-01

    Separating the retinal vascular tree into arteries and veins is important for quantifying vessel changes that preferentially affect either the veins or the arteries. For example the ratio of arterial to venous diameter, the retinal a/v ratio, is well established to be predictive of stroke and other cardiovascular events in adults, as well as the staging of retinopathy of prematurity in premature infants. This work presents a supervised, automatic method that can determine whether a vessel is an artery or a vein based on intensity and derivative information. After thinning of the vessel segmentation, vessel crossing and bifurcation points are removed leaving a set of vessel segments containing centerline pixels. A set of features is extracted from each centerline pixel and using these each is assigned a soft label indicating the likelihood that it is part of a vein. As all centerline pixels in a connected segment should be the same type we average the soft labels and assign this average label to each centerline pixel in the segment. We train and test the algorithm using the data (40 color fundus photographs) from the DRIVE database1 with an enhanced reference standard. In the enhanced reference standard a fellowship trained retinal specialist (MDA) labeled all vessels for which it was possible to visually determine whether it was a vein or an artery. After applying the proposed method to the 20 images of the DRIVE test set we obtained an area under the receiver operator characteristic (ROC) curve of 0.88 for correctly assigning centerline pixels to either the vein or artery classes.

  12. Celiac Artery Compression Syndrome

    Directory of Open Access Journals (Sweden)

    Mohammed Muqeetadnan

    2013-01-01

    Full Text Available Celiac artery compression syndrome is a rare disorder characterized by episodic abdominal pain and weight loss. It is the result of external compression of celiac artery by the median arcuate ligament. We present a case of celiac artery compression syndrome in a 57-year-old male with severe postprandial abdominal pain and 30-pound weight loss. The patient eventually responded well to surgical division of the median arcuate ligament by laparoscopy.

  13. Popliteal artery entrapment syndrome.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2010-01-01

    Popliteal artery entrapment syndrome is a rare abnormality of the anatomical relationship between the popliteal artery and adjacent muscles or fibrous bands in the popliteal fossa. The following is a case report of a 19 year old female, in whom popliteal artery entrapment syndrome was diagnosed, and successfully treated surgically. A review of literature is also presented and provides details on how PAES is classified, diagnosed both clinically and radiologically, and treated surgically.

  14. Coeliac artery compression syndrome

    OpenAIRE

    OKTAY, Özgür; MEMİŞ, Ahmet; Parildar, Mustafa; Oran, İsmail

    2003-01-01

    Celiac artery compression syndrome, also called median arcuate ligament compression syndrome, causes gastrointestinal ischemia secondary to compression of the proximal portion of the celiac artery just beyond its origin by the median arcuate ligament of the diaphragm. This syndrome is frequently demonstrated on aortography performed in patients without complaints of intestinal angina. Isolated stenosis or even occlusion of the celiac artery is always compensated for by collateral circul...

  15. Imaging the vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Davies, John R.; Weissberg, Peter L. [Addenbrooke' s Hospital and University of Cambridge, Division of Cardiovascular Medicine, Cambridge (United Kingdom); Gillard, Jonathan H. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Addenbrooke' s Hospitald, University Department of Radiology, Cambridge (United Kingdom)

    2005-07-01

    Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)

  16. Peripheral artery disease - legs

    Science.gov (United States)

    ... if they have a history of: Abnormal cholesterol Diabetes Heart disease (coronary artery disease) High blood pressure ( hypertension ) Kidney disease involving hemodialysis Smoking Stroke ( cerebrovascular disease )

  17. Deuterium labeled cannabinoids

    International Nuclear Information System (INIS)

    Complex reactions involving ring opening, ring closure and rearrangements hamper complete understanding of the fragmentation processes in the mass spectrometric fragmentation patterns of cannabinoids. Specifically labelled compounds are very powerful tools for obtaining more insight into fragmentation mechanisms and ion structures and therefore the synthesis of specifically deuterated cannabinoids was undertaken. For this, it was necessary to investigate the preparation of cannabinoids, appropriately functionalized for specific introduction of deuterium atom labels. The results of mass spectrometry with these labelled cannabinoids are described. (Auth.)

  18. Labelling Fashion Markets

    OpenAIRE

    Aspers, P.

    2008-01-01

    The present article discusses how an ethical and environmental labelling system can be implemented in fashion garment markets. Consumers act in markets that provide them with more information than their limited cognitive capacity allows them to handle. Ethical and environmental labelling in markets characterized by change, such as the fashion garment market, makes decision-making even more complicated. The ethical and environmental labelling system proposed here is designed to alleviate firms...

  19. Blood cell labelling

    International Nuclear Information System (INIS)

    The labelling of blood cells in vitro for subsequent in vivo studies was one of the earliest applications of radioactive tracers in clinical medicine and laid the foundations for many important contributions to the advancement of knowledge of human blood cell pathophysiology. The characteristics required for satisfactory clinical studies, the mechanisms of cell labelling, the problems of radiation or chemical damage to the labelled cells and some examples of modern clinical applications are described and discussed. (Author)

  20. On labelled compounds nomenclature

    International Nuclear Information System (INIS)

    Different approaches of major labelled compounds producers to their nomenclature in technical and commercial documentation are discussed. Some draft options of a standard technical guide document for labelled compounds nomenclature rules are suggested. Such a document after due discussion by the experts will serve to unification of the labelled compounds nomenclature within the frame of the CMEA member-countries co-operation in this field. The suggested options are based on the general recommendations by the International Union of Pure and Applied Chemistry and incorporate some more accurate definitions originating from the labelled compounds production and application experience

  1. Magnetic Nanostructures Spin Dynamics and Spin Transport

    CERN Document Server

    Farle, Michael

    2013-01-01

    Nanomagnetism and spintronics is a rapidly expanding and increasingly important field of research with many applications already on the market and many more to be expected in the near future. This field started in the mid-1980s with the discovery of the GMR effect, recently awarded with the Nobel prize to Albert Fert and Peter Grünberg. The present volume covers the most important and most timely aspects of magnetic heterostructures, including spin torque effects, spin injection, spin transport, spin fluctuations, proximity effects, and electrical control of spin valves. The chapters are written by internationally recognized experts in their respective fields and provide an overview of the latest status.

  2. Morphological method for automatic extraction of the coronary arteries

    International Nuclear Information System (INIS)

    Coronary arteriography is a clinically important diagnostic tool for the evaluation of coronary artery disease, and can provide detailed information. For the quantitative assessment of the coronary arteriograms. Several studies concerning the extraction of vessel edges have been published, and automatic extraction of vessel edges has been used in clinical diagnostic systems. However, these methods are not satisfactory, because manual modification by the operator is unavoidable in some cases. To reduce manual operation, accurate and automatic extraction of the coronary arteries is necessary. In this paper, we propose a new technique for automatic extraction of the coronary arteries using morphological operators. This method includes the following steps: contrast enhancement using a morphological Top-Hat operator, enhancement of thin vessels and reduction of pulse noise using a morphological erosion operator, elimination of obvious background pixels by semi-binary thresholding, and extraction of the coronary arteries by labeling and counting the area. (author)

  3. Spin-Spin Coupling in Asteroidal Binaries

    Science.gov (United States)

    Batygin, Konstantin; Morbidelli, Alessandro

    2015-11-01

    Gravitationally bound binaries constitute a substantial fraction of the small body population of the solar system, and characterization of their rotational states is instrumental to understanding their formation and dynamical evolution. Unlike planets, numerous small bodies can maintain a perpetual aspheroidal shape, giving rise to a richer array of non-trivial gravitational dynamics. In this work, we explore the rotational evolution of triaxial satellites that orbit permanently deformed central objects, with specific emphasis on quadrupole-quadrupole interactions. Our analysis shows that in addition to conventional spin-orbit resonances, both prograde and retrograde spin-spin resonances naturally arise for closely orbiting, highly deformed bodies. Application of our results to the illustrative examples of (87) Sylvia and (216) Kleopatra multi-asteroid systems implies capture probabilities slightly below ~10% for leading-order spin-spin resonances. Cumulatively, our results suggest that spin-spin coupling may be consequential for highly elongated, tightly orbiting binary objects.

  4. Hemorheological abnormalities in human arterial hypertension

    Science.gov (United States)

    Lo Presti, Rosalia; Hopps, Eugenia; Caimi, Gregorio

    2014-05-01

    Blood rheology is impaired in hypertensive patients. The alteration involves blood and plasma viscosity, and the erythrocyte behaviour is often abnormal. The hemorheological pattern appears to be related to some pathophysiological mechanisms of hypertension and to organ damage, in particular left ventricular hypertrophy and myocardial ischemia. Abnormalities have been observed in erythrocyte membrane fluidity, explored by fluorescence spectroscopy and electron spin resonance. This may be relevant for red cell flow in microvessels and oxygen delivery to tissues. Although blood viscosity is not a direct target of antihypertensive therapy, the rheological properties of blood play a role in the pathophysiology of arterial hypertension and its vascular complications.

  5. Bilateral popliteal arterial dissection.

    Science.gov (United States)

    Chen, Po-Liang; Ko, Shih-Yu; Tan, Ken-Hing

    2012-01-01

    A clinical feature of bilateral popliteal arterial dissection without involving the descending aorta, bilateral iliac, as well as femoral arteries has never been reported in the past literature. We report a 56-year-old man with hypertension and coronary artery disease who presented to our emergency department with complaints of bilateral knee pain after long-distance walking. Physical examination was notable for elevated blood pressure, but there was no palpable pulsation over dorsalis pedis arteries on his feet. Laboratory evaluation revealed a d-dimer level of 35.2 mg/L (FEU) on the day of the test and 1.2 mg/L one and a half months ago (normal level, <0.55). These findings were suggestive of a recent-onset peripheral arterial occlusive disorder. Computed tomography of the aorta showed bilateral popliteal arterial dissection with arterial intimal flap. Abdominal aorta, bilateral iliac, and femoral arteries remained intact with only arteriosclerotic change. Minimally invasive endovascular stent grafting was then performed. The patient had an uneventful recovery. PMID:21106320

  6. RHIC SPIN FLIPPER

    Energy Technology Data Exchange (ETDEWEB)

    BAI,M.; ROSER, T.

    2007-06-25

    This paper proposes a new design of spin flipper for RHIC to obtain full spin flip with the spin tune staying at half integer. The traditional technique of using an rf dipole or solenoid as spin flipper to achieve full spin flip in the presence of full Siberian snake requires one to change the snake configuration to move the spin tune away from half integer. This is not practical for an operational high energy polarized proton collider like RHIC where beam lifetime is sensitive to small betatron tune change. The design of the new spin flipper as well as numerical simulations are presented.

  7. Stable isotopes labelled compounds

    International Nuclear Information System (INIS)

    The catalogue on stable isotopes labelled compounds offers deuterium, nitrogen-15, and multiply labelled compounds. It includes: (1) conditions of sale and delivery, (2) the application of stable isotopes, (3) technical information, (4) product specifications, and (5) the complete delivery programme

  8. Labeling and Delinquency.

    Science.gov (United States)

    Adams, Mike S.; Robertson, Craig T.; Gray-Ray, Phyllis; Ray, Melvin C.

    2003-01-01

    Index comprised of six contrasting descriptive adjectives was used to measure incarcerated youths' perceived negative labeling from the perspective of parents, teachers, and peers. Results provided partial support for hypothesis that juveniles who choose a greater number of negative labels will report more frequent delinquent involvement. Labeling…

  9. Label Fusion Strategy Selection

    Directory of Open Access Journals (Sweden)

    Nicolas Robitaille

    2012-01-01

    Full Text Available Label fusion is used in medical image segmentation to combine several different labels of the same entity into a single discrete label, potentially more accurate, with respect to the exact, sought segmentation, than the best input element. Using simulated data, we compared three existing label fusion techniques—STAPLE, Voting, and Shape-Based Averaging (SBA—and observed that none could be considered superior depending on the dissimilarity between the input elements. We thus developed an empirical, hybrid technique called SVS, which selects the most appropriate technique to apply based on this dissimilarity. We evaluated the label fusion strategies on two- and three-dimensional simulated data and showed that SVS is superior to any of the three existing methods examined. On real data, we used SVS to perform fusions of 10 segmentations of the hippocampus and amygdala in 78 subjects from the ICBM dataset. SVS selected SBA in almost all cases, which was the most appropriate method overall.

  10. OR Specimen Labeling.

    Science.gov (United States)

    Zervakis Brent, Mary Ann

    2016-02-01

    Mislabeled surgical specimens jeopardize patient safety and quality care. The purpose of this project was to determine whether labeling surgical specimens with two patient identifiers would result in an 80% reduction in specimen labeling errors within six months and a 100% reduction in errors within 12 months. Our failure mode effects analysis found that the lack of two patient identifiers per label was the most unsafe step in our specimen handling process. We piloted and implemented a new process in the OR using the Plan-Do-Check-Act conceptual framework. The audit process included collecting data and making direct observations to determine the sustainability of the process change; however, the leadership team halted the direct observation audit after four months. The total number of surgical specimen labeling errors was reduced by only 60% within six months and 62% within 12 months; therefore, the goal of the project was not met. However, OR specimen labeling errors were reduced. PMID:26849982

  11. Radioiodine and its labelled compounds

    International Nuclear Information System (INIS)

    Chemical characteristics and their nuclear characteristics, types of labelled molecules,labelling procedures, direct labelling with various oxidizing agents, indirect labelling with various conjugates attached to protein molecules, purification and quality control. Iodination damage.Safe handling of labelling procedures with iodine radioisotopes.Bibliography

  12. Decoherence dynamics of a single spin versus spin ensemble

    NARCIS (Netherlands)

    Dobrovitski, V.V.; Feiguin, A.E.; Awschalom, D.D.; Hanson, R.

    2008-01-01

    We study decoherence of central spins by a spin bath, focusing on the difference between measurement of a single central spin and measurement of a large number of central spins (as found in typical spin-resonance experiments). For a dilute spin bath, the single spin demonstrates Gaussian free-induct

  13. Spin projection chromatography

    OpenAIRE

    Danieli, Ernesto P.; Pastawski, Horacio M.; Levstein, Patricia R.

    2003-01-01

    We formulate the many-body spin dynamics at high temperature within the non-equilibrium Keldysh formalism. For the simplest XY interaction, analytical expressions in terms of the one particle solutions are obtained for linear and ring configurations. For small rings of even spin number, the group velocities of excitations depend on the parity of the total spin projection. This should enable a dynamical filtering of spin projections with a given parity i.e. a Spin projection chromatography.

  14. Sensing remote nuclear spins

    OpenAIRE

    Zhao, Nan; Honert, Jan; Schmid, Berhard; Isoya, Junichi; Markham, Mathew; Twitchen, Daniel; Jelezko, Fedor; Liu, Ren-Bao; Fedder, Helmut; Wrachtrup, Jörg

    2012-01-01

    Sensing single nuclear spins is a central challenge in magnetic resonance based imaging techniques. Although different methods and especially diamond defect based sensing and imaging techniques in principle have shown sufficient sensitivity, signals from single nuclear spins are usually too weak to be distinguished from background noise. Here, we present the detection and identification of remote single C-13 nuclear spins embedded in nuclear spin baths surrounding a single electron spins of a...

  15. Topological Spin Hall Effect

    OpenAIRE

    Yin, Gen; Liu, Yizhou; Barlas, Yafis; Zang, Jiadong; Lake, Roger K.

    2015-01-01

    The intrinsic spin Hall effect (SHE) originates from the topology of the Bloch bands in momentum space. The duality between real space and momentum space calls for a spin Hall effect induced from a real space topology in analogy to the topological Hall effect (THE) of skyrmions. We theoretically demonstrate the topological spin Hall effect (TSHE) in which a pure transverse spin current is generated from a skyrmion spin texture.

  16. Intrinsic Spin Hall Effect

    OpenAIRE

    Murakami, Shuichi

    2005-01-01

    A brief review is given on the spin Hall effect, where an external electric field induces a transverse spin current. It has been recognized over 30 years that such effect occurs due to impurities in the presence of spin-orbit coupling. Meanwhile, it was proposed recently that there is also an intrinsic contribution for this effect. We explain the mechanism for this intrinsic spin Hall effect. We also discuss recent experimental observations of the spin Hall effect.

  17. Spin projection chromatography

    Science.gov (United States)

    Danieli, E. P.; Pastawski, H. M.; Levstein, P. R.

    2004-01-01

    We formulate the many-body spin dynamics at high temperature within the non-equilibrium Keldysh formalism. For the simplest XY interaction, analytical expressions in terms of the one particle solutions are obtained for linear and ring configurations. For small rings of even spin number, the group velocities of excitations depend on the parity of the total spin projection. This should enable a dynamical filtering of spin projections with a given parity i.e., a spin projection chromatography.

  18. Entangled spins and ghost-spins

    CERN Document Server

    Jatkar, Dileep P

    2016-01-01

    We study patterns of quantum entanglement in systems of spins and ghost-spins regarding them as simple quantum mechanical toy models for theories containing negative norm states. We define a single ghost-spin as in arXiv:1602.06505 [hep-th] as a 2-state spin variable with an indefinite inner product in the state space. We find that whenever the spin sector is disentangled from the ghost-spin sector (both of which could be entangled within themselves), the reduced density matrix obtained by tracing over all the ghost-spins gives rise to positive entanglement entropy for positive norm states, while negative norm states have an entanglement entropy with a negative real part and a constant imaginary part. However when the spins are entangled with the ghost-spins, there are new entanglement patterns in general. For systems where the number of ghost-spins is even, it is possible to find subsectors of the Hilbert space where positive norm states always lead to positive entanglement entropy after tracing over the gho...

  19. Hybrid Spin Noise Spectroscopy and the Spin Hall Effect

    OpenAIRE

    Slipko, V. A.; Sinitsyn, N. A.; Pershin, Y. V.

    2013-01-01

    Here we suggest a novel hybrid spin noise spectroscopy technique, which is sensitive to the spin Hall effect. It is shown that, while the standard spin-spin correlation function is not sensitive to the spin Hall effect, spin-transverse voltage and transverse voltage-voltage correlation functions provide the missing sensitivity being linear and quadratic in the spin Hall coefficient, respectively. The correlation between transverse voltage and spin fluctuations appears as a result of spin-char...

  20. Nutrition Facts: Reading the Label

    Science.gov (United States)

    ... My Go4Life Get Free Stuff Be a Partner Nutrition Facts: Reading the Label Reading labels can help ... of information on their labels or packaging about nutrition and food safety. Product dates . You might see ...

  1. Noncommutativity due to spin

    CERN Document Server

    Gomes, M; da Silva, A J

    2010-01-01

    Using the Berezin-Marinov pseudoclassical formulation of spin particle we propose a classical model of spin noncommutativity. In the nonrelativistic case, the Poisson brackets between the coordinates are proportional to the spin angular momentum. The quantization of the model leads to the noncommutativity with mixed spacial and spin degrees of freedom. A modified Pauli equation, describing a spin half particle in an external e.m. field is obtained. We show that nonlocality caused by the spin noncommutativity depends on the spin of the particle; for spin zero, nonlocality does not appear, for spin half, $\\Delta x\\Delta y\\geq\\theta^{2}/2$, etc. In the relativistic case the noncommutative Dirac equation was derived. For that we introduce a new star product. The advantage of our model is that in spite of the presence of noncommutativity and nonlocality, it is Lorentz invariant. Also, in the quasiclassical approximation it gives noncommutativity with a nilpotent parameter.

  2. Noncommutativity due to spin

    Science.gov (United States)

    Gomes, M.; Kupriyanov, V. G.; da Silva, A. J.

    2010-04-01

    Using the Berezin-Marinov pseudoclassical formulation of the spin particle we propose a classical model of spin noncommutativity. In the nonrelativistic case, the Poisson brackets between the coordinates are proportional to the spin angular momentum. The quantization of the model leads to the noncommutativity with mixed spatial and spin degrees of freedom. A modified Pauli equation, describing a spin half particle in an external electromagnetic field is obtained. We show that nonlocality caused by the spin noncommutativity depends on the spin of the particle; for spin zero, nonlocality does not appear, for spin half, ΔxΔy≥θ2/2, etc. In the relativistic case the noncommutative Dirac equation was derived. For that we introduce a new star product. The advantage of our model is that in spite of the presence of noncommutativity and nonlocality, it is Lorentz invariant. Also, in the quasiclassical approximation it gives noncommutativity with a nilpotent parameter.

  3. Noncommutativity due to spin

    International Nuclear Information System (INIS)

    Using the Berezin-Marinov pseudoclassical formulation of the spin particle we propose a classical model of spin noncommutativity. In the nonrelativistic case, the Poisson brackets between the coordinates are proportional to the spin angular momentum. The quantization of the model leads to the noncommutativity with mixed spatial and spin degrees of freedom. A modified Pauli equation, describing a spin half particle in an external electromagnetic field is obtained. We show that nonlocality caused by the spin noncommutativity depends on the spin of the particle; for spin zero, nonlocality does not appear, for spin half, ΔxΔy≥θ2/2, etc. In the relativistic case the noncommutative Dirac equation was derived. For that we introduce a new star product. The advantage of our model is that in spite of the presence of noncommutativity and nonlocality, it is Lorentz invariant. Also, in the quasiclassical approximation it gives noncommutativity with a nilpotent parameter.

  4. Coronary Artery Bypass

    Directory of Open Access Journals (Sweden)

    Kadri Ceberut

    2011-01-01

    Full Text Available Ancient schwannoma is a rare variant of neural tumors though rarely seen in the thorax. The combination with coronary artery diseases is also rare. Here we describe a 66 year-old male who had undergone one-stage combined surgery for thoracic ancient schwannomas removal and coronary artery disease. The masses were, respectively, 13 cm in the middle mediastinum and 5 cm in diameter originating from the intercostal nerve. The tumors were successfully removed using sternotomy, and then a coronary artery bypass grafting was performed. Here we discuss this rare tumor in relation to the relevant literature.

  5. Radioactive labelled orgotein

    International Nuclear Information System (INIS)

    The preparation and use of radioactively labelled orgotein, i.e. water-soluble protein congeners in pure, injectable form, is described. This radiopharmaceutical is useful in scintigraphy, especially for visualization of the kidneys where the orgotein is rapidly concentrated. Details of the processes for labelling bovine orgotein with sup(99m)Tc, 60Co, 125I or 131I are specified. The pharmaceutical preparation of the labelled orgotein for intravenous and parenteral administration is also described. Examples using either sup(99m)TC or 125I-orgotein in scintiscanning dogs' kidneys are given. (UK)

  6. Spin conductivity in almost integrable spin chains

    OpenAIRE

    Jung, Peter; Rosch, Achim

    2007-01-01

    The spin conductivity in the integrable spin-1/2 XXZ-chain is known to be infinite at finite temperatures T for anisotropies -1 < Delta < 1. Perturbations which break integrability, e.g. a next-nearest neighbor coupling J', render the conductivity finite. We construct numerically a non-local conserved operator J_parallel which is responsible for the finite spin Drude weight of the integrable model and calculate its decay rate for small J'. This allows us to obtain a lower bound for the spin c...

  7. Clinical applications of cells labelling

    International Nuclear Information System (INIS)

    Blood cells labelled with radionuclides are reviewed and main applications are described. Red blood cell labelling by both random and specific principle. A table with most important clinical uses, 99mTc labelling of RBC are described pre tinning and in vivo reduction of Tc, in vitro labelling and administration of labelled RBC and in vivo modified technique. Labelled leucocytes with several 99mTc-complex radiopharmaceuticals by in vitro technique and specific monoclonal s for white cells(neutrofiles). Labelled platelets for clinical use and research by in vitro technique and in vivo labelling

  8. FDA Online Label Repository

    Data.gov (United States)

    U.S. Department of Health & Human Services — The drug labels and other drug-specific information on this Web site represent the most recent drug listing information companies have submitted to the Food and...

  9. Like your labels?

    Science.gov (United States)

    Field, Michele

    2010-01-01

    The descriptive “conventions” used on food labels are always evolving. Today, however, the changes are so complicated (partly driven by legislation requiring disclosures about environmental impacts, health issues, and geographical provenance) that these labels more often baffle buyers than enlighten them. In a light-handed manner, the article points to how sometimes reading label language can be like deciphering runes—and how if we are familiar with the technical terms, we can find a literal meaning, but still not see the implications. The article could be ten times longer because food labels vary according to cultures—but all food-exporting cultures now take advantage of our short attention-span when faced with these texts. The question is whether less is more—and if so, in this contest for our attention, what “contestant” is voted off. PMID:21539053

  10. Peripheral Arterial Disease

    Science.gov (United States)

    Peripheral arterial disease (PAD) happens when there is a narrowing of the blood vessels outside of your heart. The cause of ... smoking. Other risk factors include older age and diseases like diabetes, high blood cholesterol, high blood pressure, ...

  11. Coronary artery spasm

    Science.gov (United States)

    ... blocker or a long-acting nitrate long-term. Beta-blockers are another type of medicine that is used with other coronary artery problems. However, beta-blockers may make this problem worse. They should be ...

  12. Pulmonary Arterial Hypertension

    Science.gov (United States)

    Pulmonary Arterial Hypertension What Is Pulmonary Hypertension? To understand pulmonary hypertension (PH) it helps to understand how blood ows throughout your body. While the heart is one organ, it ...

  13. Carotid artery disease

    Science.gov (United States)

    ... you have had a stroke or TIA, a nervous system (neurological) exam will show other problems. You may also have the following tests: Blood cholesterol and triglycerides test Blood sugar (glucose) test Ultrasound of the carotid arteries ( carotid ...

  14. MR imaging of the arterial wall in normal volunteers and arteriosclerotic patients

    International Nuclear Information System (INIS)

    MR angiography is based on the signal characteristics of flowing blood, whereas the arterial wall is not delineated. Its visualization requires maximal spatial resolution and reliable compensation for moving spins. Presaturation and rephasing gradients were applied to spin-echo and fast low-angle shot (FLASH) sequences combined with a reduction of the field of view to approximately 10 cm. Three-dimensional FLASH sequences demonstrated spin saturation within the imaging volume without additional radio-frequency pulses and was sensitive to alterations in the arterial wall. CHESS techniques (fat sensitive) suppressed signal from the normal arterial wall. Small fatty or sclerotic deposits in the femoral, popliteal, and carotid walls were detected prior to marked stenosis

  15. Certified Rule Labeling

    OpenAIRE

    Nagele, Julian; Zankl, Harald

    2015-01-01

    The rule labeling heuristic aims to establish confluence of (left-)linear term rewrite systems via decreasing diagrams. We present a formalization of a confluence criterion based on the interplay of relative termination and the rule labeling in the theorem prover Isabelle. Moreover, we report on the integration of this result into the certifier CeTA, facilitating the checking of confluence certificates based on decreasing diagrams for the first time. The power of the method is illustrated by ...

  16. Labelling of Vincamine derivatives

    International Nuclear Information System (INIS)

    Tritium labelled Vincamine and ethyl apovincaminate (Cavinton) have been prepared on the bases of known stereospecific synthesis. High specific activity compounds were obtained by the catalytic tritiation of appropriate unsaturated starting compounds. When the structure of the unsaturated starting compounds was changed (even rather for from the reaction centre) instead of the catalytic addition of tritium a specific hydrogen-tritium exchange reaction was found to be the main labelling process

  17. Labelling of electricity

    International Nuclear Information System (INIS)

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) presents a possible course of action to be taken to provide a means of declaring the sources of electrical power, as is foreseen in the draft of new Swiss electricity market legislation. The report presents the basic ideas behind the idea and defines the terms used such as labelling, certificates and declarations. Also, the legal situation in the European Union and in Switzerland is examined and a quantitative overview of electricity production and consumption is presented. Suggestions for a labelling scheme are made and some of the problems to be expected are looked at. The report also presents a series of examples of labelling schemes already implemented in other countries, such as Austria, Great Britain, Sweden and Germany. Tradable certificates and tracking systems are discussed as are initial quality labels like the Swiss 'Naturemade' label for green power. A concrete recommendation for the declaration and labelling of electricity in Switzerland is presented and various factors to be considered such as import/export, pumped storage, distribution losses, small-scale producers as well as the time-scales for introduction are discussed

  18. Streaming Label Learning for Modeling Labels on the Fly

    OpenAIRE

    You, Shan; Xu, Chang; Wang, Yunhe; Xu, Chao; Tao, Dacheng

    2016-01-01

    It is challenging to handle a large volume of labels in multi-label learning. However, existing approaches explicitly or implicitly assume that all the labels in the learning process are given, which could be easily violated in changing environments. In this paper, we define and study streaming label learning (SLL), i.e., labels are arrived on the fly, to model newly arrived labels with the help of the knowledge learned from past labels. The core of SLL is to explore and exploit the relations...

  19. Off label use of devices and drugs in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zvavanjanja, R.C., E-mail: Rodrick.Zvavanjanja@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool (United Kingdom); Odetoyinbo, T.O.; Rowlands, P.C.; Healey, A.; Abdelsalam, H.; Powell, S.; Evans, J.C.; Hughes, M.L.; Gould, D.A.; McWilliams, R.G. [Royal Liverpool University Hospital, Liverpool (United Kingdom)

    2012-03-15

    Aim: To establish how often off-label device and drug use occurs in interventional radiology (IR) in a UK tertiary referral hospital and consider the wider implications for the interventional radiologist. Materials and methods: Prospective data were collected during interventional procedures for 1 working week in a university hospital. Out-of-hours procedures and procedures outside the department were excluded. Operators were asked to record the drugs and devices used, the indication, and method of use. The instructions for use/summary of product characteristics were then studied for each device/drug used to assess if the use was on or off-label. Results: During the study period 52 cases were performed and data were available on 26 cases (50%). In 22 of the 26 cases (84%) there was evidence of off-label use of devices or drugs. Off-label use of drugs included treatment of venous malformations with Fibrovein{sup Copyright-Sign} (sodium tetradecyl sulphate), which is licensed for the treatment of varicose veins in the leg, and intra-arterial injection of heparin, which is licensed for intravenous and subcutaneous use. Off-label device use included placing vascular sheaths in the urinary tract, using angiographic catheters to guide wires in the urinary tract, using sheaths for thrombosuction, reshaping of the tip of most guidewires, and using angioplasty balloons to dislodge the arterial plug at fistula thrombectomy. Conclusion: Off-label device and drugs use is common in a UK tertiary hospital IR department and literature suggests this is common in the wider IR community. There are important clinical and legal implications for off-label use for patients and physicians.

  20. Off label use of devices and drugs in interventional radiology

    International Nuclear Information System (INIS)

    Aim: To establish how often off-label device and drug use occurs in interventional radiology (IR) in a UK tertiary referral hospital and consider the wider implications for the interventional radiologist. Materials and methods: Prospective data were collected during interventional procedures for 1 working week in a university hospital. Out-of-hours procedures and procedures outside the department were excluded. Operators were asked to record the drugs and devices used, the indication, and method of use. The instructions for use/summary of product characteristics were then studied for each device/drug used to assess if the use was on or off-label. Results: During the study period 52 cases were performed and data were available on 26 cases (50%). In 22 of the 26 cases (84%) there was evidence of off-label use of devices or drugs. Off-label use of drugs included treatment of venous malformations with Fibrovein© (sodium tetradecyl sulphate), which is licensed for the treatment of varicose veins in the leg, and intra-arterial injection of heparin, which is licensed for intravenous and subcutaneous use. Off-label device use included placing vascular sheaths in the urinary tract, using angiographic catheters to guide wires in the urinary tract, using sheaths for thrombosuction, reshaping of the tip of most guidewires, and using angioplasty balloons to dislodge the arterial plug at fistula thrombectomy. Conclusion: Off-label device and drugs use is common in a UK tertiary hospital IR department and literature suggests this is common in the wider IR community. There are important clinical and legal implications for off-label use for patients and physicians.

  1. Arbitrary Spin Galilean Oscillator

    CERN Document Server

    Hagen, C R

    2014-01-01

    The so-called Dirac oscillator was proposed as a modification of the free Dirac equation which reproduces many of the properties of the simple harmonic oscillator but accompanied by a strong spin-orbit coupling term. It has yet to be extended successfully to the arbitrary spin S case primarily because of the unwieldiness of general spin Lorentz invariant wave equations. It is shown here using the formalism of totally symmetric multispinors that the Dirac oscillator can, however, be made to accommodate spin by incorporating it into the framework of Galilean relativity. This is done explicitly for spin zero and spin one as special cases of the arbitrary spin result. For the general case it is shown that the coefficient of the spin-orbit term has a 1/S behavior by techniques which are virtually identical to those employed in the derivation of the g-factor carried out over four decades ago.

  2. Diagnosis of labelled platelets scintigraphy in patients with cardiovascular diseases

    International Nuclear Information System (INIS)

    Scintigraphy with [111 In] oxine labelled platelets is a powerful tool to detect platelet deposits in heart and vessels. This quantitative and functional imaging method needs a labeling procedure which completely preserves the properties of the platelets and allows the concept of hematologically active clot. Four main groups of patients are able to profit by this method. 1) Patients with intra-cardiac thrombi detected by 2D-echography. Platelet scintigraphy specified the hematologically active pattern of the clot and allows the follow-up of pharmacological therapy. 2) Patients with lower limb ischemia, mainly in the case of blue toe syndrome. The aortic or iliac seat of the lesions, their unique or plurifocal patterns are better localized with platelet scintigraphy than other imaging methods. 3) Patients with transient cerebro-vascular accidents. A focal deposit of platelets on carotid arteries is a strong argument for surgery. As in the cases of intra-cardiac thrombi, the method allows the follow-up of pharmacological therapy. 4) Patients with arterial grafts. Platelet scintigraphy provides the mean to follow the thrombogenic behaviour of the material and the preventive effects of anti-thrombic drugs. Platelets labelled with 111 Indium provide the means for sensitive and specific detection of hematologically active clots in cardiac and arterial pathology

  3. Indium-111-labeled platelet scintigraphy in carotid atherosclerosis

    International Nuclear Information System (INIS)

    We evaluated platelet accumulation in carotid arteries by means of a dual-radiotracer method, using indium-111-labeled platelets and technetium-99m-labeled human serum albumin, in 123 patients (92 men, 31 women; median age 60 years). Sixty patients had symptoms of transient ischemic carotid artery disease, and 63 patients with peripheral arterial occlusive disease served as controls. Antiplatelet treatment with acetylsalicylic acid was taken by 53 of the 123 patients. In 36 of the 60 symptomatic patients, platelet scintigraphy was repeated 3-4 days after carotid endarterectomy. Comparison of different scintigraphic parameters (platelet accumulation index and percent of the injected dose of labeled platelets at the carotid bifurcation) showed no significant differences between symptomatic and asymptomatic patients, and the severity of stenosis and the presence of plaque ulceration also had no influence on the parameters. There was no difference between patients with a short (less than 4 weeks) or long (greater than 4 weeks) interval from the last transient ischemic attack to scintigraphy and no difference between patients with or without antiplatelet treatment. Classifying the patients according to plaque morphology judged by high-resolution real-time ultrasonography also demonstrated no differences. No significant correlation was found between any scintigraphic parameter and other platelet function parameters such as platelet survival time, platelet turnover rate, and concentration of platelet-specific proteins. Quantification of platelet deposition after carotid endarterectomy in 36 patients demonstrated a significant increase of the median platelet accumulation index and the percent injected dose index

  4. A Beautiful Spin

    International Nuclear Information System (INIS)

    Spin is a beautiful concept that plays an ever important role in modern physics. In this talk, I start with a discussion of the origin of spin, and then turn to three themes in which spin has been crucial in subatomic physics: a lab to explore physics beyond the standard model, a tool to measure physical observables that are hard to obtain otherwise, a probe to unravel nonperturbative QCD. I conclude with some remarks on a world without spin

  5. Spin Hall Effect

    OpenAIRE

    Schliemann, John

    2006-01-01

    It is proposed that when a charge current circulates in a paramagnetic metal a transverse spin imbalance will be generated, giving rise to a 'spin Hall voltage'. Similarly, that when a spin current circulates a transverse charge imbalance will be generated, hence a Hall voltage, in the absence of charge current and magnetic field. Based on these principles we propose an experiment to generate and detect a spin current in a paramagnetic metal.

  6. Eco-labelling, competition and environment: Endogenization of labelling criteria

    OpenAIRE

    Ben Youssef, Adel; Lahmandi-Ayed, Rim

    2008-01-01

    This paper suggests a modelling of the labelling procedure consistent with empirical observations, that allows the endogenous calculation of labelling criteria. The authority in charge of the labelling program chooses the level of labelling criteria so as to maximise the social surplus, anticipating competition between firms in environmental qualities and prices. While accounting simply for the informational role of labels, this model allows to understand observed behavior such as firms' igno...

  7. On online labeling with polynomially many labels

    Czech Academy of Sciences Publication Activity Database

    Babka, M.; Bulánek, Jan; Čunát, V.; Koucký, Michal; Saks, M.

    Berlin : Springer, 2012 - (Epstein, L.; Ferragina, P.), s. 121-132 ISBN 978-3-642-33089-6. - (Lecture Notes in Computer Science. 7501). [20th Annual European Symposium on Algorithms (ESA 2012). Ljubljana (SI), 10.09.2012-12.09.2012] R&D Projects: GA ČR GAP202/10/0854; GA AV ČR IAA100190902 Institutional support: RVO:67985840 Keywords : online labeling * file maintenance problem * lower bounds Subject RIV: BA - General Mathematics http://link.springer.com/chapter/10.1007/978-3-642-33090-2_12

  8. European consumers and nutrition labelling

    DEFF Research Database (Denmark)

    Wills, Josephine M.; Grunert, Klaus G.; Celemín, Laura Fernández;

    2009-01-01

    Nutrition labelling of food in Europe is not compulsory, unless a nutrition or health claim is made for the product. The European Commission is proposing mandatory nutrition labelling, even front of pack labelling with nutrition information. Yet, how widespread is nutrition labelling in the EU...

  9. Genetic algorithms for map labeling

    NARCIS (Netherlands)

    Dijk, Steven Ferdinand van

    2002-01-01

    Map labeling is the cartographic problem of placing the names of features (for example cities or rivers) on the map. A good labeling has no intersections between labels. Even basic versions of the problem are NP-hard. In addition, realistic map-labeling problems deal with many cartographic constr

  10. Off-Label Drug Use

    Science.gov (United States)

    ... Your Local Offices Close + - Text Size Off-label Drug Use What is off-label drug use? In the United States new drugs are ... unapproved use of a drug. Is off-label drug use legal? The off-label use of FDA- ...

  11. The Beauty of Spin

    OpenAIRE

    Meißner, Ulf-G.

    2010-01-01

    I review recent developments in theoretical spin physics. Topics include pion production in nucleon-nucleon collisions, the implications of heavy quark spin symmetry for heavy hadron molecules, the nucleon electric dipole form factors and ab initio calculations of the width of hadron resonances. A few spin physics high-lights from experiments at the COSY accelerator are also discussed.

  12. Nuclear spins of surfaces

    International Nuclear Information System (INIS)

    Nuclear spin polarized atomic probes (alkali atoms) can be used to investigate the microscopic properties of solid surfaces. NMR and relaxation studies are discussed for nuclear spin polarized alkali atoms chemisorbed on hot metal surfaces. The use of nuclear spin-polarized radioactive nuclei, which allows the extension of this method to cold surfaces, is mentioned briefly. (orig.)

  13. Spin-torque transistor

    NARCIS (Netherlands)

    Bauer, G.E.W.; Brataas, A.; Tserkovnyak, Y.; Van Wees, B.J.

    2003-01-01

    A magnetoelectronic thin-film transistor is proposed that can display negative differential resistance and gain. The working principle is the modulation of the soure–drain current in a spin valve by the magnetization of a third electrode, which is rotated by the spin-torque created by a control spin

  14. Spinning Eggs and Ballerinas

    Science.gov (United States)

    Cross, Rod

    2013-01-01

    Measurements are presented on the rise of a spinning egg. It was found that the spin, the angular momentum and the kinetic energy all decrease as the egg rises, unlike the case of a ballerina who can increase her spin and kinetic energy by reducing her moment of inertia. The observed effects can be explained, in part, in terms of rolling friction…

  15. Concepts in spin electronics

    CERN Document Server

    2006-01-01

    A new branch of physics and nanotechnology called spin electronics has emerged, which aims at simultaneously exploiting the charge and spin of electrons in the same device. The aim of this book is to present new directions in the development of spin electronics in both the basic physics and the future electronics.

  16. Radio labeling with preassigned frequencies.

    OpenAIRE

    2004-01-01

    A radio labeling of a graph G is an assignment of pairwise distinct, positive integer labels to the vertices of G such that labels of adjacent vertices differ by at least $2$. The radio labeling problem (RL) consists in determining a radio labeling that minimizes the maximum label that is used (the so-called span of the labeling). RL is a well-studied problem, mainly motivated by frequency assignment problems in which transmitters are not allowed to operate on the same frequency channel. We c...

  17. Radioactive labelling of peptidic hormones

    International Nuclear Information System (INIS)

    The labelling of peptidic hormones requires stability, specificity and sensitivity of the label. Introduction of a radioactive atome is one way to satisfy these criteria. Several processes have been described to prepare radioactive TRF: synthesis of the peptide with labelled aminoacids or introduction of the label into the hormone. In that approach, tritium can be substituted in the imidazole ring, via precursors activating the proper carbon. Monoiodo TRF leads essentially to tritium labelling of the 5 positions whereas monoazo TRF allows the preparation of 3H TRF labelled in the 2 positions. Di-substituted TRF leads to labelling into the 2 and 5 carbons. Labelled analogs of TRF can be prepared with labelled iodine; further developments of peptide labelling, will be presented. In particular, the homolytic scission of the C-iodine, bond by photochemical activation. The nascent carbon radical can be stabilized by a tritiated scavenger. This approach eliminates the use of heavy metal catalysts

  18. Folosirea spectrometrului RES ART-6 IFIN in studii cu markeri de spin

    International Nuclear Information System (INIS)

    Characteristics of the ESR spectrometer ART-6, made at the Institute of Phzsics and Nuclear Engineering (IFIN), Magurele-Bucharest (sensitivity 3x1011 spin/G, resolving power 100 mG, magnetic field stability 2x1q-5, frequency stability 2x10-6) are presented along with the instrumental parameters used in the study of spin labels, 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO) and 3-methylene-5-(piperinide-N-methyl)-4-oxo-2,2,6,6-tetramethylpiperidine-1oxyl. These spin labels were used for the investigation of some biological membranes. 40 ref. (authors)

  19. Fully automated segmentation of carotid and vertebral arteries from CTA

    OpenAIRE

    Cuisenaire, Olivier

    2009-01-01

    We propose a method for segmenting and labeling the main head and neck vessels (common, internal, external carotid and vertebral arteries) from a contrast enhanced computed tomography angiography (CTA) volume. First, an initial centerline of each vessel is extracted. Next, the vessels are segmented using 3D active objects initialized using the first step. Finally, the true centerline is identified by smoothly deforming it away from the segmented mask edges using a spline-snake. We focus parti...

  20. An artery-specific fluorescent dye for studying neurovascular coupling

    OpenAIRE

    Shen, Zhiming; Lu, Zhongyang; Chhatbar, Pratik Y.; O’Herron, Philip; Kara, Prakash

    2012-01-01

    We demonstrate that Alexa Fluor 633 hydrazide (Alexa Fluor 633) selectively labels neocortical arteries and arterioles by binding to elastin fibers. We measured sensory stimulus–evoked arteriole dilation dynamics in mouse, rat and cat visual cortex using Alexa Fluor 633 together with neuronal activity using calcium indicators or blood flow using fluorescein dextran. Arteriole dilation decreased fluorescence recorded from immediately underlying neurons, representing a potential artifact during...

  1. Coronary arterial fistulas

    Directory of Open Access Journals (Sweden)

    Qureshi Shakeel A

    2006-12-01

    Full Text Available Abstract A coronary arterial fistula is a connection between one or more of the coronary arteries and a cardiac chamber or great vessel. This is a rare defect and usually occurs in isolation. Its exact incidence is unknown. The majority of these fistulas are congenital in origin although they may occasionally be detected after cardiac surgery. They do not usually cause symptoms or complications in the first two decades, especially when small. After this age, the frequency of both symptoms and complications increases. Complications include 'steal' from the adjacent myocardium, thrombosis and embolism, cardiac failure, atrial fibrillation, rupture, endocarditis/endarteritis and arrhythmias. Thrombosis within the fistula is rare but may cause acute myocardial infarction, paroxysmal atrial fibrillation and ventricular arrhythmias. Spontaneous rupture of the aneurysmal fistula causing haemopericardium has also been reported. The main differential diagnosis is patent arterial duct, although other congenital arteriovenous shunts need to be excluded. Whilst two-dimensional echocardiography helps to differentiate between the different shunts, coronary angiography is the main diagnostic tool for the delineation of the anatomy. Surgery was the traditional method of treatment but nowadays catheter closure is recommended using a variety of closure devices, such as coils, or other devices. With the catheter technique, the results are excellent with infrequent complications. Disease name and synonyms Coronary arterial fistulas Coronary arterial fistulas or malformations

  2. Synthesis of labeled compounds

    International Nuclear Information System (INIS)

    Intermediate compounds labeled with 13C included methane, sodium cyanide, methanol, ethanol, and acetonitrile. A new method for synthesizing 15N-labeled 4-ethylsulfonyl-1-naphthalene-sulfonamide was developed. Studies were conducted on pathways to oleic-1-13C acid and a second pathway investigated was based on carbonation of 8-heptadecynylmagnesium bromide with CO2 to prepare sterolic acid. Biosynthetic preparations included glucose-13C from starch isolated from tobacco leaves following photosynthetic incubation with 13CO2 and galactose-13C from galactosylglycerol-13C from kelp. Research on growth of organisms emphasized photosynthetic growth of algae in which all cellular carbon is labeled. Preliminary experiments were performed to optimize the growth of Escherichia coli on sodium acetate-13C

  3. Fluorine-18 labelled compounds

    International Nuclear Information System (INIS)

    The work presented in this thesis deals with the problems involved in the adaption of reactor-produced fluorine-18 to the synthesis of 18F-labelled organic fluorine compounds. Several 18F-labelling reagents were prepared and successfully applied. The limitations to the synthetic possibilities of reactor-produced fluoride-18 become manifest in the last part of the thesis. An application to the synthesis of labelled aliphatic fluoro amino acids has appeared to be unsuccessful as yet, although some other synthetic approaches can be indicated. Seven journal articles (for which see the availability note) are used to compose the four chapters and three appendices. The connecting text gives a survey of known 18F-compounds and methods for preparing such compounds. (Auth.)

  4. Spin supplementary conditions for spinning compact binaries

    CERN Document Server

    Mikóczi, Balázs

    2016-01-01

    We consider the different spin supplementary conditions (SSC) for a spinning compact binary with the leading-order spin-orbit (SO) interaction. The Lagrangian of the binary system can be constructed but it is acceleration-dependent in two cases of SSC. We rewrite the generalized Hamiltonian formalism proposed by Ostrogradsky and compute the conservative quantities and the dissipative part of relative motion during the gravitational radiation of each SSCs. We give the orbital elements and observed quantities of the SO dynamics, for instance the energy and the orbital angular momentum losses and waveforms and discuss their SSC dependence.

  5. Inverse spin Hall effect by spin injection

    Science.gov (United States)

    Liu, S. Y.; Horing, Norman J. M.; Lei, X. L.

    2007-09-01

    Motivated by a recent experiment [S. O. Valenzuela and M. Tinkham, Nature (London) 442, 176 (2006)], the authors present a quantitative microscopic theory to investigate the inverse spin-Hall effect with spin injection into aluminum considering both intrinsic and extrinsic spin-orbit couplings using the orthogonalized-plane-wave method. Their theoretical results are in good agreement with the experimental data. It is also clear that the magnitude of the anomalous Hall resistivity is mainly due to contributions from extrinsic skew scattering.

  6. Norepinephrine release in arteries of spontaneously hypertensive rats

    International Nuclear Information System (INIS)

    The role of the sympathetic nervous system in arterial hypertension cannot be properly evaluated until it is known about the activity in the vessels themselves. In this study researchers investigated the effect of transmural stimulation on the tail artery - labelled in vitro with 3H-norepinephrine - of 7-9 week old spontaneously hypertensive rats (SHR) and Wistar Kyoto controls (WKR). Electrical stimulation using two frequencies (2 and 10 Hz) resulted in significantly more 3H overflow in vessels from SHR than from WKR. With 10 Hz stimulation the fractional release was also greater. Column chromatographic analysis of 3H overflow revealed that transmural stimulation in arteries of SHR enhanced mainly the release of norepinephrine and not of its metabolites. Significantly, an increased release of 3H-norepinephrine on stimulation was observed in SHR before the full development of hypertension suggesting that it might be a cause rather than a consequence of high blood pressure

  7. Anomalous right coronary artery arising from left anterior descending artery

    Directory of Open Access Journals (Sweden)

    M.L. Sreenivas Kumar

    2012-07-01

    Full Text Available A 54-year-old male patient presented with acute myocardial infarction involving left anterior descending and right coronary artery territories. Coronary angiogram showed a single coronary artery with right coronary artery arising from left anterior descending artery (LAD, which coursed anterior to right ventricular outflow tract and thrombotic lesion in mid left anterior descending artery before origin of right coronary artery. The patient was treated with thrombolytic therapy and glycoprotein IIb/IIIa inhibitors. Anomalous origin of right coronary artery as a branch of LAD is a very rare type of congenital coronary artery anomalies. It is important to recognize this anomaly as it can be associated with extensive myocardial ischemia and sudden cardiac death in young persons even without atherosclerosis.

  8. Proteoglycans in primate arteries. III. Characterization of the proteoglycans synthesized by arterial smooth muscle cells in culture

    OpenAIRE

    1983-01-01

    Near confluent monolayers of arterial smooth muscle cells derived from Macaca nemestrina were labeled with Na2[35S]O4 and the newly synthesized proteoglycans present in the culture medium and cell layer were extracted with either 4 M guanidine HCl (dissociative solvent) or 0.5 M guanidine HCl (associative solvent) in the presence of protease inhibitors. The proteoglycans in both compartments were further purified by cesium chloride density gradient ultracentrifugation. Two size classes of pro...

  9. Semantic Role Labeling

    CERN Document Server

    Palmer, Martha; Xue, Nianwen

    2011-01-01

    This book is aimed at providing an overview of several aspects of semantic role labeling. Chapter 1 begins with linguistic background on the definition of semantic roles and the controversies surrounding them. Chapter 2 describes how the theories have led to structured lexicons such as FrameNet, VerbNet and the PropBank Frame Files that in turn provide the basis for large scale semantic annotation of corpora. This data has facilitated the development of automatic semantic role labeling systems based on supervised machine learning techniques. Chapter 3 presents the general principles of applyin

  10. Left main coronary artery compression in pulmonary arterial hypertension

    DEFF Research Database (Denmark)

    Al-Badri, Kadhem Helo Abbas; Jensen, Jesper Møller; Christiansen, Evald H;

    2015-01-01

    In patients with pulmonary arterial hypertension (PAH), chest pain is most likely due to right ventricular demand ischemia. We report a patient with idiopathic PAH who developed severe angina due to extrinsic compression of the left main coronary artery (LMCA) from a dilated pulmonary artery trunk...

  11. Left Anterior Descending Artery-Pulmonary Artery Fistula

    Directory of Open Access Journals (Sweden)

    Turan Ege

    2011-12-01

    Full Text Available Despite the fact that coronary arteriovenous fistulas constitute approximately half (48% of coronary artery anomalies, they are rarely seen anomalies. In this report,we aim to present a coronary arteriovenous fistula case detected during a coronary angiography between left anterior descending artery and pulmonary artery.

  12. Carotid artery stenting

    International Nuclear Information System (INIS)

    An ipsilateral stenosis of the internal carotid artery is found in 10 - 15 % of all ischemic strokes and indicates an increased risk of a second stroke. Carotid artery stenting (CAS) is a therapy that is established for many years. CAS reveals complication rates and long-term efficacy comparable to carotid endarterectomy (TEA). Especially younger patients seem to benefit from CAS. Abilities and experiences of the therapist and the choice of the techniques used are critical for patient safety. The efficacy of CAS for treatment of asymptomatic carotid stenosis is probable but still unproven in prospective-randomized trial. (orig.)

  13. Carotid artery stenting; Karotisangioplastie

    Energy Technology Data Exchange (ETDEWEB)

    Fiehler, Jens [Universitaetsklinikum Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Neuroradiologische Diagnostik und Intervention, Diagnostikzentrum

    2009-09-15

    An ipsilateral stenosis of the internal carotid artery is found in 10 - 15 % of all ischemic strokes and indicates an increased risk of a second stroke. Carotid artery stenting (CAS) is a therapy that is established for many years. CAS reveals complication rates and long-term efficacy comparable to carotid endarterectomy (TEA). Especially younger patients seem to benefit from CAS. Abilities and experiences of the therapist and the choice of the techniques used are critical for patient safety. The efficacy of CAS for treatment of asymptomatic carotid stenosis is probable but still unproven in prospective-randomized trial. (orig.)

  14. Muon spin relaxation in random spin systems

    International Nuclear Information System (INIS)

    The longitudinal relaxation function Gsub(z)(t) of the positive muon can reflect dynamical characters of local field in a unique way even when the correlation time is longer than the Larmor period of local field. This method has been applied to studies of spin dynamics in spin glass systems, revealing sharp but continuous temperature dependence of the correlation time. Its principle and applications are reviewed. (author)

  15. About Peripheral Artery Disease (PAD)

    Science.gov (United States)

    ... Tools & Resources Stroke More About Peripheral Artery Disease (PAD) Updated:Mar 23,2016 Peripheral artery disease (PAD) ... critical regions of the body. Quick Facts about PAD View an illustration of PAD The most common ...

  16. Pharmacological modulation of arterial stiffness.

    LENUS (Irish Health Repository)

    Boutouyrie, Pierre

    2011-09-10

    Arterial stiffness has emerged as an important marker of cardiovascular risk in various populations and reflects the cumulative effect of cardiovascular risk factors on large arteries, which in turn is modulated by genetic background. Arterial stiffness is determined by the composition of the arterial wall and the arrangement of these components, and can be studied in humans non-invasively. Age and distending pressure are two major factors influencing large artery stiffness. Change in arterial stiffness with drugs is an important endpoint in clinical trials, although evidence for arterial stiffness as a therapeutic target still needs to be confirmed. Drugs that independently affect arterial stiffness include antihypertensive drugs, mostly blockers of the renin-angiotensin-aldosterone system, hormone replacement therapy and some antidiabetic drugs such as glitazones. While the quest continues for \\'de-stiffening drugs\\

  17. Combined arterial and venous whole-body MR angiography with cardiac MR imaging in patients with thromboembolic disease - initial experience

    International Nuclear Information System (INIS)

    The objective was to assess the feasibility of a combined arterial and venous whole-body three-dimensional magnetic resonance (MR) angiography, together with a cardiac MR examination, in patients with arterial thromboembolism. Ten patients with arterial thromboembolism underwent a contrast-enhanced whole-body MR examination of the arterial and venous vessels, followed by a cardiac MR examination on a separate occasion within 24 h. All examinations were performed on a 1.5-T MR scanner. For both arterial and venous MR angiography only one injection of contrast agent was necessary. The cardiac imaging protocol included dark-blood-prepared half-Fourier acquisition single-shot turbo-spin-echo sequences, fast steady-state free precession cine sequences, T2-weighted turbo-spin-echo sequences and inversion recovery gradient-echo fast low-angle-shot sequences after injection of contrast agent. MR imaging revealed additional clinically unknown arterial thromboembolisms in four patients. The thoracic aorta was depicted as embolic source in four patients, while deep vein thrombosis (DVT) was found in one patient as the underlying disease. Unsuspected infarction of parenchymal organs was detected by MRI in two patients. An unknown additional DVT was found in one patient. Four patients were considered to have arterial emboli of cardiac origin. In conclusion, acquisition of arterial and venous MR angiograms of the entire vascular system combined with cardiac MR imaging is a most comprehensive and valuable strategy in patients with arterial thromboembolism. (orig.)

  18. Combined arterial and venous whole-body MR angiography with cardiac MR imaging in patients with thromboembolic disease - initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, Florian M.; Hunold, Peter; Barkhausen, Joerg [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Herborn, Christoph U. [University Hospital Hamburg-Eppendorf, Medical Prevention Center Hamburg (MPCH) at University Hospital Hamburg-Eppendorf, Hamburg (Germany); Ruehm, Stefan G. [David Geffen School of Medicine at UCLA, Department of Radiology, Los Angeles, CA (United States); Kroger, Knut [University Hospital Essen, Department of Angiology, Essen (Germany)

    2008-05-15

    The objective was to assess the feasibility of a combined arterial and venous whole-body three-dimensional magnetic resonance (MR) angiography, together with a cardiac MR examination, in patients with arterial thromboembolism. Ten patients with arterial thromboembolism underwent a contrast-enhanced whole-body MR examination of the arterial and venous vessels, followed by a cardiac MR examination on a separate occasion within 24 h. All examinations were performed on a 1.5-T MR scanner. For both arterial and venous MR angiography only one injection of contrast agent was necessary. The cardiac imaging protocol included dark-blood-prepared half-Fourier acquisition single-shot turbo-spin-echo sequences, fast steady-state free precession cine sequences, T2-weighted turbo-spin-echo sequences and inversion recovery gradient-echo fast low-angle-shot sequences after injection of contrast agent. MR imaging revealed additional clinically unknown arterial thromboembolisms in four patients. The thoracic aorta was depicted as embolic source in four patients, while deep vein thrombosis (DVT) was found in one patient as the underlying disease. Unsuspected infarction of parenchymal organs was detected by MRI in two patients. An unknown additional DVT was found in one patient. Four patients were considered to have arterial emboli of cardiac origin. In conclusion, acquisition of arterial and venous MR angiograms of the entire vascular system combined with cardiac MR imaging is a most comprehensive and valuable strategy in patients with arterial thromboembolism. (orig.)

  19. Effect of cigarette smoke, nicotine, and carbon monoxide on the permeability of the arterial wall

    International Nuclear Information System (INIS)

    The association between cigarette smoking and the development of atherosclerosis is well established, but the mechanism that makes cigarettes such a potent risk factor is not understood. There is normally a constant insudation of plasma macromolecules into the arterial wall. Fibrinogen and lipids are two of the large molecules involved in atherosclerosis. Therefore, we studied the effect of cigarette smoke, nicotine, and carbon monoxide on the permeability of the canine arterial wall to 125I-labeled fibrinogen. The results show that inhaled cigarette smoke significantly and rapidly increases the permeability of the arterial wall to fibrinogen and that this effect can be produced with carbon monoxide alone but not with intravenous nicotine

  20. Combination of rare right arterial variation with anomalous origins of the vertebral artery, aberrant subclavian artery and persistent trigeminal artery. A case report.

    Science.gov (United States)

    Ishihara, H; San Millán Ruíz, D; Abdo, G; Asakura, F; Yilmaz, H; Lovblad, K O; Rüfenacht, D A

    2011-09-01

    A 32-year-old woman hospitalized for subarachnoid hemorrhage showed rare arterial variation on the right side with anomalous origins of the vertebral artery, aberrant subclavian artery and persistent trigeminal artery. Angiography showed the right vertebral artery to originate from the right common carotid artery, the right subclavian artery to arise separately from the descending aorta, and persistent trigeminal artery on the right side. The possible embryonic mechanism of this previously unreported variant combination is discussed. PMID:22005696

  1. Radioactively labelled porphyrin derivatives

    International Nuclear Information System (INIS)

    Radioactive labelling of guanidine bearing tetraphenylporphyrin and Dy-texaphyrin with 166Ho and 90Y is described. UV-VIS absorption spectrometry was used to describe porphyrin and texaphyrin, including their behaviour over a wide pH range. This technique also provided preliminary information about the complexation of holmium and yttrium with porphyrin and texaphyrin. The labelling yield of the macrocyclic molecules depends on the pH of the reaction mixture, metal-to-ligand ratio and time of incubation. The optimum reaction conditions for the formation of radioactive complexes of porphyrin and texaphyrin were determined by thin layer chromatography combined with beta activity measurement. The ability of porphyrin derivatives to bind anions was also examined. Our experiments were focused on perrhenate ion (ReO4-) because radiopharmaceuticals labeled with 186Re and 188Re play an important role in the therapy of many tumorous diseases. The possibility of using the ReO4- anion directly for labeling without reduction to a lower oxidation state can simplify considerably the preparation of the radiotherapeutic pharmaceuticals. Neither UV-Vis spectrometry nor TLC gave evidence of any incorporation of the ReO4- anion into the porphyrin ring

  2. Labeling of herbicide femesafen

    International Nuclear Information System (INIS)

    5-[2-chroo-4-(trifluoromethyl ) phenoxy]-N-(methyl sulphonyl )-2-niorobenzamide [femesafen] was labeled by six steps. Radio-chemical yield was 19.15%. TLC analysis of the final product showed that the radiochemical purity is not less than 99%. (authors)

  3. Waisda?: video labeling game

    NARCIS (Netherlands)

    Hildebrand, M.; Brinkerink, M.; Gligorov, R.; Steenbergen, M. van; Huijkman, J.; Oomen, J.

    2013-01-01

    The Waisda? video labeling game is a crowsourcing tool to collect user-generated metadata for video clips. It follows the paradigm of games-with-a-purpose, where two or more users play against each other by entering tags that describe the content of the video. Players score points by entering the sa

  4. Understanding Food Labels

    Science.gov (United States)

    ... girls Eating healthy at restaurants Special food issues Vegetarian eating Eating for strong bones Quiz: Food Facts Links to more information girlshealth glossary girlshealth.gov home http://www.girlshealth.gov/ Home Nutrition Healthy eating for girls Understanding food labels Understanding ...

  5. Stabilization of labelled compounds

    International Nuclear Information System (INIS)

    This invention concerns a composition including a labelled compound, and the vitamin B 12. This vitamin gives a red colour to the solution and stabilize it radiochemically, allowing to transport the solution at ambient temperature and a storage at 4 degrees celsius. (N.C.). 5 refs

  6. Liver cirrhosis and arterial hypertension

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik; Møller, Søren

    2006-01-01

    blood pressure. This review considers the alterations in systemic hemodynamics in patients with cirrhosis in relation to essential hypertension and arterial hypertension of the renal origin. Subjects with arterial hypertension (essential, secondary) may become normotensive during the development of...... cirrhosis, and arterial hypertension is rarely manifested in patients with cirrhosis, even in cases with renovascular disease and high circulating renin activity. There is much dispute as to the understanding of homoeostatic regulation in cirrhotic patients with manifest arterial hypertension. This most...

  7. Genetic algorithms for map labeling

    OpenAIRE

    Dijk, Steven Ferdinand van

    2002-01-01

    Map labeling is the cartographic problem of placing the names of features (for example cities or rivers) on the map. A good labeling has no intersections between labels. Even basic versions of the problem are NP-hard. In addition, realistic map-labeling problems deal with many cartographic constraints, which pose more demands on how the labels should be placed in relation to their surroundings. For example, a label is preferably placed above and to the right of a city. These two aspects (comb...

  8. Spin Hall effects

    Science.gov (United States)

    Sinova, Jairo; Valenzuela, Sergio O.; Wunderlich, J.; Back, C. H.; Jungwirth, T.

    2015-10-01

    Spin Hall effects are a collection of relativistic spin-orbit coupling phenomena in which electrical currents can generate transverse spin currents and vice versa. Despite being observed only a decade ago, these effects are already ubiquitous within spintronics, as standard spin-current generators and detectors. Here the theoretical and experimental results that have established this subfield of spintronics are reviewed. The focus is on the results that have converged to give us the current understanding of the phenomena, which has evolved from a qualitative to a more quantitative measurement of spin currents and their associated spin accumulation. Within the experimental framework, optical-, transport-, and magnetization-dynamics-based measurements are reviewed and linked to both phenomenological and microscopic theories of the effect. Within the theoretical framework, the basic mechanisms in both the extrinsic and intrinsic regimes are reviewed, which are linked to the mechanisms present in their closely related phenomenon in ferromagnets, the anomalous Hall effect. Also reviewed is the connection to the phenomenological treatment based on spin-diffusion equations applicable to certain regimes, as well as the spin-pumping theory of spin generation used in many measurements of the spin Hall angle. A further connection to the spin-current-generating spin Hall effect to the inverse spin galvanic effect is given, in which an electrical current induces a nonequilibrium spin polarization. This effect often accompanies the spin Hall effect since they share common microscopic origins. Both can exhibit the same symmetries when present in structures comprising ferromagnetic and nonmagnetic layers through their induced current-driven spin torques or induced voltages. Although a short chronological overview of the evolution of the spin Hall effect field and the resolution of some early controversies is given, the main body of this review is structured from a pedagogical

  9. Persistent Trigeminal Artery

    Directory of Open Access Journals (Sweden)

    Dijo T George

    2015-04-01

    Full Text Available Trigeminal artery is the commonest of the four primitive anastomoses between the carotid and vertebrobasilar system that may rarely persist in adults, with an angiographic incidence of 0.1 - 0.6%. We present the CT and MR angiograms of a patient who presented with a minor stroke and was detected to have this anomaly and briefly discuss the significance

  10. Spin caloritronics in graphene

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Angsula; Frota, H. O. [Department of Physics, Federal University of Amazonas, Av. Rodrigo Octavio 3000-Japiim, 69077-000 Manaus, AM (Brazil)

    2015-06-14

    Spin caloritronics, the combination of spintronics with thermoelectrics, exploiting both the intrinsic spin of the electron and its associated magnetic moment in addition to its fundamental electronic charge and temperature, is an emerging technology mainly in the development of low-power-consumption technology. In this work, we study the thermoelectric properties of a Rashba dot attached to two single layer/bilayer graphene sheets as leads. The temperature difference on the two graphene leads induces a spin current, which depends on the temperature and chemical potential. We demonstrate that the Rashba dot behaves as a spin filter for selected values of the chemical potential and is able to filter electrons by their spin orientation. The spin thermopower has also been studied where the effects of the chemical potential, temperature, and also the Rashba term have been observed.

  11. Basilar Artery Aneurysm at a Persistent Trigeminal Artery Junction

    Science.gov (United States)

    Aguiar, G.B.; Conti, M.L.M.; Veiga, J.C.E.; Jory, M.; Souza, R.B.

    2011-01-01

    Summary The trigeminal artery is an anastomosis between the embryonic precursors of the vertebrobasilar and carotid systems, and may persist into adult life. The association of the persistent primitive trigeminal artery (PTA) with cerebral aneurysm is well documented in the literature and, in general, aneurysms are located in the anterior circulation. We describe a patient who presented with a panencephalic Fisher III subarachnoid hemorrhage due to rupture of an intracranial aneurysm. Digital arteriography showed a saccular aneurysm in the middle third of the basilar artery, adjacent to the junction with a persistent trigeminal artery. She was submitted to endovascular treatment with embolization of the basilar artery aneurysm with coils. Aneurysms at the PTA junction with the basilar artery are rare. This paper describes a case of PTA associated with an aneurysm in the basilar artery at PTA junction and briefly reviews the literature. PMID:22005697

  12. Spin Transfer Torques

    OpenAIRE

    Ralph, D. C.; Stiles, M. D.

    2007-01-01

    This tutorial article introduces the physics of spin transfer torques in magnetic devices. We provide an elementary discussion of the mechanism of spin transfer torque, and review the theoretical and experimental progress in this field. Our intention is to be accessible to beginning graduate students. This is the introductory paper for a cluster of "Current Perspectives" articles on spin transfer torques published in volume 320 of the Journal of Magnetism and Magnetic Materials. This article ...

  13. Spin Hall effect transistor

    Czech Academy of Sciences Publication Activity Database

    Wunderlich, Joerg; Park, B.G.; Irvine, A.C.; Zarbo, Liviu; Rozkotová, E.; Němec, P.; Novák, Vít; Sinova, Jairo; Jungwirth, Tomáš

    2010-01-01

    Roč. 330, č. 6012 (2010), s. 1801-1804. ISSN 0036-8075 R&D Projects: GA AV ČR KAN400100652; GA MŠk LC510 Grant ostatní: EU FP7 SemiSpinNet(XE) 215368 Institutional research plan: CEZ:AV0Z10100521 Keywords : spin Hall effect * spintronics * spin transistor Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 31.364, year: 2010

  14. Anyons as spinning particles

    OpenAIRE

    Cortes, J. L.; Plyushchay, M. S.

    1995-01-01

    A model-independent formulation of anyons as spinning particles is presented. The general properties of the classical theory of (2+1)-dimensional relativistic fractional spin particles and some properties of their quantum theory are investigated. The relationship between all the known approaches to anyons as spinning particles is established. Some widespread misleading notions on the general properties of (2+1)-dimensional anyons are removed.

  15. Spin Hall noise

    OpenAIRE

    Kamra, A.; Witek, F.P.; Meyer, S.; Huebl, H.; Geprägs, S.; Gross, R.; Bauer, G. E. W.; Goennenwein, S. T. B.

    2014-01-01

    We measure the low-frequency thermal fluctuations of pure spin current in a Platinum film deposited on yttrium iron garnet via the inverse spin Hall effect (ISHE)-mediated voltage noise as a function of the angle $\\alpha$ between the magnetization and the transport direction. The results are consistent with the fluctuation dissipation theorem in terms of the recently discovered spin Hall magnetoresistance (SMR). We present a microscopic description of the $\\alpha$ dependence of the voltage no...

  16. Nuclear spin noise imaging

    OpenAIRE

    Müller, Norbert; Jerschow, Alexej

    2006-01-01

    NMR images were obtained from the proton spin noise signals of a water-containing phantom, which was placed in the highly tuned, low-noise resonant circuit of a cryogenically cooled NMR probe in the presence of systematically varied magnetic field gradients. The spatially resolved proton spin density was obtained from the raw signal by a modified projection–reconstruction protocol. Although spin noise imaging is inherently less sensitive than conventional magnetic resonance imaging, it afford...

  17. Nonequilibrium spin noise spectroscopy

    OpenAIRE

    Li, Fuxiang; Pershin, Yuriy V.; Slipko, Valeriy A.; Sinitsyn, Nikolai A.

    2013-01-01

    Spin Noise Spectroscopy (SNS) is an experimental approach to obtain correlators of mesoscopic spin fluctuations in time by purely optical means. We explore the information that this technique can provide when it is applied to a weakly non-equilibrium regime when an electric current is driven through a sample by an electric field. We find that the noise power spectrum of conducting electrons experiences a shift, which is proportional to the strength of the spin-orbit coupling for electrons mov...

  18. Spin Hall effect devices

    Czech Academy of Sciences Publication Activity Database

    Jungwirth, Tomáš; Wunderlich, Joerg; Olejník, Kamil

    2012-01-01

    Roč. 11, č. 5 (2012), s. 382-390. ISSN 1476-1122 EU Projects: European Commission(XE) 215368 - SemiSpinNet Grant ostatní: FP7 - ERC Advanced Grant 0MSPIN(XE) 268066; AVČR(CZ) Premium Academiae Institutional research plan: CEZ:AV0Z10100521 Keywords : spin Hall effect * spintronic s * spin transistor Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 35.749, year: 2012

  19. Use the Nutrition Facts Label

    Science.gov (United States)

    ... Features Spokespeople News Archive eNewsletters Calendar Use the Nutrition Facts Label You can help your family eat ... to some of their favorite foods. Use the Nutrition Facts label found on food packages to make ...

  20. Labeling lake water with tritium

    Science.gov (United States)

    Frederick, B.J.

    1963-01-01

    A method of packaging tritiated water in a manner that facilitates safe handling in environmental labeling operations, and procedures followed in labeling a large body of water with a small volume of tritiated water are described. ?? 1963.

  1. Spin Waves in Terbium

    DEFF Research Database (Denmark)

    Jensen, J.; Houmann, Jens Christian Gylden; Bjerrum Møller, Hans

    1975-01-01

    The energies of spin waves propagating in the c direction of Tb have been studied by inelastic neutron scattering, as a function of a magnetic field applied along the easy and hard directions in the basal plane, and as a function of temperature. From a general spin Hamiltonian, consistent...... with the symmetry, we deduce the dispersion relation for the spin waves in a basal-plane ferromagnet. This phenomenological spin-wave theory accounts for the observed behavior of the magnon energies in Tb. The two q⃗-dependent Bogoliubov components of the magnon energies are derived from the experimental results...

  2. Straintronic spin-neuron

    OpenAIRE

    Biswas, Ayan K.; Atulasimha, Jayasimha; Bandyopadhyay, Supriyo

    2015-01-01

    In artificial neural networks, neurons are usually implemented with highly dissipative CMOS-based operational amplifiers. A more energy-efficient implementation is a 'spin-neuron' realized with a magneto-tunneling junction (MTJ) that is switched with a spin-polarized current (representing weighted sum of input currents) that either delivers a spin transfer torque or induces domain wall motion in the soft layer of the MTJ. Here, we propose and analyze a different type of spin-neuron in which t...

  3. Cardiopulmonary fitness correlates with regional cerebral grey matter perfusion and density in men with coronary artery disease.

    Directory of Open Access Journals (Sweden)

    Bradley J MacIntosh

    Full Text Available PURPOSE: Physical activity is associated with positive effects on the brain but there is a paucity of clinical neuroimaging data in patients with coronary artery disease (CAD, a cardiovascular condition associated with grey matter loss. The purpose of this study was to determine which brain regions are impacted by cardiopulmonary fitness and with the change in fitness after 6 months of exercise-based cardiac rehabilitation. METHODS: CAD patients underwent magnetic resonance imaging at baseline, and peak volume of oxygen uptake during exercise testing (VO2Peak was measured at baseline and after 6 months of training. T1-weighted structural images were used to perform grey matter (GM voxel-based morphometry (VBM. Pseudo-continuous arterial spin labeling (pcASL was used to produce cerebral blood flow (CBF images. VBM and CBF data were tested voxel-wise using VO2Peak and age as explanatory variables. RESULTS: In 30 men with CAD (mean age 65±7 years, VBM and CBF identified 7 and 5 respective regions positively associated with baseline VO2Peak. These included the pre- and post-central, paracingulate, caudate, hippocampal regions and converging findings in the putamen. VO2Peak increased by 20% at follow-up in 29 patients (t = 9.6, df = 28, p<0.0001. Baseline CBF in the left post-central gyrus and baseline GM density in the right putamen predicted greater change in VO2Peak. CONCLUSION: Perfusion and GM density were associated with fitness at baseline and with greater fitness gains with exercise. This study identifies new neurobiological correlates of fitness and demonstrates the utility of multi-modal MRI to evaluate the effects of exercise in CAD patients.

  4. Cluster Algorithms for General-S Quantum Spin Systems

    International Nuclear Information System (INIS)

    We present a general strategy to extend quantum cluster algorithms for S=1/2 spin systems, such as the loop algorithm, to those with an arbitrary size of spins. The partition function of a high-S spin system is generally represented by the path integral of a S=1/2 model with special boundary conditions in the imaginary-time direction. We introduce additional graphs for the boundary part and give the labeling probability explicitly, which completes the algorithm together with an existing S=1/2 algorithm. As a demonstration, we simulate the integer-spin antiferromagnetic Heisenberg chains. The magnitude of the first excitation gap is estimated to be 0.41048(6), 0.08917(4), and 0.01002(3) for S=1 , 2, and 3, respectively

  5. Screening asymptomatic patients with diabetes for unknown coronary artery disease: Does it reduce risk? An open-label randomized trial comparing a strategy based on exercise testing aimed at revascularization with management based on pharmacological/behavioural treatment of traditional risk factors. DADDY-D Trial (Does coronary Atherosclerosis Deserve to be Diagnosed and treated early in Diabetics?

    Directory of Open Access Journals (Sweden)

    Romano Stefania

    2009-12-01

    Full Text Available Abstract Background Coronary artery disease is the leading cause of morbidity and mortality in patients with type 2 diabetes. Screening for asymptomatic coronary artery disease with treatment by means of revascularization seems to be an appealing option for prevention. The utility of such a strategy has never been challenged in a randomized trial. Methods/Design In the present study a cohort of diabetic patients without any symptoms and without known coronary artery disease will be screened at two diabetes outpatients services. Those with intermediate or high risk (equal or greater than 10% according to the Italian risk chart will be asked to participate and enrolled. They will be seen and followed in order to provide the best adherence to medical therapy. Half of the patients will be randomized to undergo an exercise tolerance testing while the other group will continue to be regularly seen at diabetes outpatients services. Best medical/behavioral therapy will be offered to both groups. Those patients with a positive exercise tolerance testing will be studied by coronary angiography and treated according to the severity of coronary lesions by percutaneous stenting or surgery. The objective of the study is to evaluate the efficacy of the screening strategy aimed at revascularization. A cost-effectiveness analysis will be performed at the end of the follow up. Discussion The study will provide useful information about prevention and treatment of diabetic patients at high risk of coronary events. It will be made clearer if detection of silent coronary artery disease has to be recommended and followed by treatment. Given the simplicity of the study protocol, it will be easily transferable to the real world. Trial registration (ClinicalTrials.gov: NCT00547872

  6. Food Labels Tell the Story!

    Science.gov (United States)

    ... My World From the Label to the Table! Food Labels Tell the Story! What is in food? Food provides your body with all of the ... your food choices. Nutrition Facts—the Labels on Food Products Beginning in 1994, the US government began ...

  7. Isotopically labelled benzodiazepines

    International Nuclear Information System (INIS)

    This paper reports on the benzodiazepines which are a class of therapeutic agents. Improvements in the analytical methodology in the areas of biochemistry and pharmacology were significant, particularly in the application of chromatographic and spectroscopic techniques. In addition, the discovery and subsequent development of tritium and carbon-14 as an analytical tool in the biological sciences were essentially post-world war II phenomena. Thus, as these new chemical entities were found to be biologically active, they could be prepared in labeled form for metabolic study, biological half-life determination (pharmacokinetics), tissue distribution study, etc. This use of tracer methodology has been liberally applied to the benzodiazepines and also more recently to the study of receptor-ligand interactions, in which tritium, carbon-11 or fluorine-18 isotopes have been used. The history of benzodiazepines as medicinal agents is indeed an interesting one; an integral part of that history is their use in just about every conceivable labeled form

  8. Nomenclature for labelled compounds

    International Nuclear Information System (INIS)

    This paper report on isotopically labelled compounds. The first indexing system for isotopically labelled organic compounds is generally credited to Boughton and named after him. An extension of his principles for designating compounds containing hydrogen isotopes has been part of the Chemical Abstracts Service index nomenclature system for many years. After close on five years labor the IUPAC sponsored Commission on Nomenclature of Organic Chemistry presented in 1979 their findings on Isotopically Modified Compounds. The system codified in their rules provides for recognition of various types of isotopic modification and is therefore of more general applicability. Concurrently the rules for the nomenclature of isotopically modified inorganic compounds are developed. These are to be seen as supplementing and extending the guidelines laid down in the IUPAC Inorganic Nomenclature Rules already published

  9. Labelling, Deviance and Media

    OpenAIRE

    Greer, C.

    2014-01-01

    Labelling theory is a perspective that emerged as a distinctive approach to criminology during the 1960s, and was a major seedbed of the radical and critical perspectives that became prominent in the 1970s. It represented the highpoint of an epistemological shift within the social sciences away from positivism – which had dominated criminological enquiry since the late-1800s – and toward an altogether more relativistic stance on the categories and concepts of crime and control. It inspired a ...

  10. Eco-labelling

    OpenAIRE

    Kuna-Marszałek, Anetta

    2016-01-01

    Considering environmental protection requirements in business operations may, in the long run, determine if a lasting comparative advantage can be achieved. That is why our textbook, rich in case studies, identifies not only the threats a business may pose to the environment but stresses the ways of reducing its negative impact. It discusses, among other things, the concept of corporate social responsibility, environmental management systems, methods and the importance of eco-labelling goods ...

  11. Probing spin-charge separation using spin transport

    OpenAIRE

    Si, Qimiao

    2000-01-01

    Pedagogical discussions are given on what constitutes a signature of spin-charge separation. A proposal is outlined to probe spin-charge separation in the normal state of the high $T_c$ cuprates using spin transport. Specifically, the proposal is to compare the temperature dependences of the spin resistivity and electrical resistivity: Spin-charge separation will be manifested in the different temperature dependences of these two resistivities. We also estimate the spin diffusion length and s...

  12. Quantum theory of spin waves in finite chiral spin chains

    OpenAIRE

    Roldán-Molina, A.; Santander, M. J.; Núñez, A.S.; Fernández Rossier, Joaquín

    2013-01-01

    We calculate the effect of spin waves on the properties of finite-size spin chains with a chiral spin ground state observed on biatomic Fe chains deposited on iridium(001). The system is described with a Heisenberg model supplemented with a Dzyaloshinskii-Moriya coupling and a uniaxial single ion anisotropy that presents a chiral spin ground state. Spin waves are studied using the Holstein-Primakoff boson representation of spin operators. Both the renormalized ground state and the elementary ...

  13. Sildenafil in pediatric pulmonary arterial hypertension

    Directory of Open Access Journals (Sweden)

    A K Dhariwal

    2015-01-01

    Full Text Available Pulmonary arterial hypertension (PAH is a life-threatening disease of varied etiologies. Although PAH has no curative treatment, a greater understanding of pathophysiology, technological advances resulting in early diagnosis, and the availability of several newer drugs have improved the outlook for patients with PAH. Sildenafil is one of the therapeutic agents used extensively in the treatment of PAH in children, as an off-label drug. In 2012, the United States Food and Drug Administration (USFDA issued a warning regarding the of use high-dose sildenafil in children with PAH. This has led to a peculiar situation where there is a paucity of approved therapies for the management of PAH in children and the use of the most extensively used drug being discouraged by the regulator. This article provides a review of the use of sildenafil in the treatment of PAH in children.

  14. Fluorescence labeling to study platelet and leucocyte deposition onto vascular grafts in vitro.

    Science.gov (United States)

    Toes, G J; van den Dungen, J J; Haan, J; Hermens, R A; van Oeveren, W

    1999-10-01

    Platelets and leucocytes are important participants in the response of the body to small diameter vascular grafts implanted into the arterial circulation. A sensitive and quick method for measuring platelet and leucocyte deposition contributes to material evaluation. With a newly developed fluorescence labeling method we examined the deposition of platelets and leucocytes onto vascular grafts in vitro. Human platelets and leucocytes were isolated and labeled with the fluorescence label Europium trichloride (EuCl3). After reconstitution of the labeled cells in plasma their functionality appeared intact and competitive with unlabeled cells. Eu-labeled platelets or leucocytes were then incubated with expanded polytetrafluoroethylene (ePTFE), Dacron and polyurethane (PU) vascular grafts in autologous plasma. Beta-thromboglobin and thromboxane release from platelets and beta-glucuronidase release from leucocytes during the incubation experiments were measured. Platelets and leucocytes deposited significantly less onto ePTFE compared to Dacron and polyurethane (P release. PMID:10514073

  15. Indium-111 labelled platelets: experimental and clinical studies

    International Nuclear Information System (INIS)

    The object of the present study became to develop a method of effective and gentle isolation and 111-In labelling of human platelets, as well as to employ these platelets in human clinical studies with the object of elucidating a number of physiological and pathophysiological mechanisms and processes in which platelets take part. 111-In-oxine presents obvious advantages over 51-Cr-sodium chromate; a high labelling efficiency, and more advantageous physical properties (a half life of 68 hours (against the half life of 28 days for 51-Cr) and considerably more effective gamma emission), making external registration by means of a gamma camera possible. Considering the role played by platelets in the development of atherosclerosis and its thromboembolic complications, in the early phases of deep venous thrombosis, and in graft rejection, it is natural that attempts have been made to use 111-In-labelled platelets for scintigraphic and kinetic evaluation of thromboembolic processes. Accumulation of 111-In-labelled platelets at sites of vessel wall injury, on pulmonary emboli (presumably on deep vein thrombi as well), and on catheter material has been demonstrated. Beyond this, the number of publications concerning the use of 111-In-labelled platelets for visualization of atherosclerosis, venous thromboembolism, arterial grafts, intracardiac thrombi, aortic aneurysms, renal allograft rejection, and other situations in which platelet thromboembolism takes place, provides evidence that a tool has finally been found for the study of their nature and response to therapeutic intervention. (eg)

  16. Antiferromagnetic spin Seebeck effect.

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Stephen M.; Zhang, Wei; KC, Amit; Borisov, Pavel; Pearson, John E.; Jiang, J. Samuel; Lederman, David; Hoffmann, Axel; Bhattacharya, Anand

    2016-03-03

    We report on the observation of the spin Seebeck effect in antiferromagnetic MnF2. A device scale on-chip heater is deposited on a bilayer of MnF2 (110) (30nm)/Pt (4 nm) grown by molecular beam epitaxy on a MgF2(110) substrate. Using Pt as a spin detector layer, it is possible to measure the thermally generated spin current from MnF2 through the inverse spin Hall effect. The low temperature (2–80 K) and high magnetic field (up to 140 kOe) regime is explored. A clear spin-flop transition corresponding to the sudden rotation of antiferromagnetic spins out of the easy axis is observed in the spin Seebeck signal when large magnetic fields (>9T) are applied parallel to the easy axis of the MnF2 thin film. When the magnetic field is applied perpendicular to the easy axis, the spin-flop transition is absent, as expected.

  17. Single-spin CCD

    Science.gov (United States)

    Baart, T. A.; Shafiei, M.; Fujita, T.; Reichl, C.; Wegscheider, W.; Vandersypen, L. M. K.

    2016-04-01

    Spin-based electronics or spintronics relies on the ability to store, transport and manipulate electron spin polarization with great precision. In its ultimate limit, information is stored in the spin state of a single electron, at which point quantum information processing also becomes a possibility. Here, we demonstrate the manipulation, transport and readout of individual electron spins in a linear array of three semiconductor quantum dots. First, we demonstrate single-shot readout of three spins with fidelities of 97% on average, using an approach analogous to the operation of a charge-coupled device (CCD). Next, we perform site-selective control of the three spins, thereby writing the content of each pixel of this ‘single-spin charge-coupled device’. Finally, we show that shuttling an electron back and forth in the array hundreds of times, covering a cumulative distance of 80 μm, has negligible influence on its spin projection. Extrapolating these results to the case of much larger arrays points at a diverse range of potential applications, from quantum information to imaging and sensing.

  18. Spin Waves in Terbium

    DEFF Research Database (Denmark)

    Jensen, J.; Houmann, Jens Christian Gylden; Bjerrum Møller, Hans

    1975-01-01

    The energies of spin waves propagating in the c direction of Tb have been studied by inelastic neutron scattering, as a function of a magnetic field applied along the easy and hard directions in the basal plane, and as a function of temperature. From a general spin Hamiltonian, consistent with th...

  19. Spin stripes in nanotubes

    OpenAIRE

    Kleiner, Alex

    2002-01-01

    It is shown here that electrons on the surface of a nanotube in a perpendicular magnetic field undergo spin-chirality separation along the circumference. Stripes of spin-polarization propagate along the tube, with a spatial pattern that can be modulated by the electron filling.

  20. Centralizers of spin subalgebras

    Science.gov (United States)

    Arizmendi, Gerardo; Herrera, Rafael

    2015-11-01

    We determine the centralizers of certain isomorphic copies of spin subalgebras spin(r) in so(dr m), where dr is the dimension of a real irreducible representation of Clr0, the even Clifford algebra determined by the positive definite inner product on Rr, where r, m ∈ N.

  1. Spin torque transistor revisited

    NARCIS (Netherlands)

    Chiba, T.; Bauer, G.E.W.; Takahashi, S.

    2013-01-01

    We theoretically study the operation of a 4-terminal device consisting of two lateral thin-film spin valves that are coupled by a magnetic insulator such as yttrium iron garnet via the spin transfer torque. By magnetoelectronic circuit theory we calculate the current voltage characteristics and find

  2. Spin Hall noise

    NARCIS (Netherlands)

    Kamra, A.; Witek, F.P.; Meyer, S.; Huebl, H.; Geprägs, S.; Gross, R.; Bauer, G.E.W.; Goennenwein, S.T.B.

    2014-01-01

    We measure the low-frequency thermal fluctuations of pure spin current in a platinum film deposited on yttrium iron garnet via the inverse spin Hall effect (ISHE)-mediated voltage noise as a function of the angle α between the magnetization and the transport direction. The results are consistent wit

  3. More spinoff from spin

    International Nuclear Information System (INIS)

    Despite playing a major role in today's Standard Model, spin - the intrinsic angular momentum carried by particles - is sometimes dismissed as an inessential complication. However several major spin questions with important implications for the Standard Model remain unanswered, and recent results and new technological developments made the 10th International Symposium on High Energy Spin Physics, held in Nagoya, Japan, in November, highly topical. The symposium covered a wide range of physics, reflecting the diversity of spin effects, however four main themes were - the spin content of the nucleon, tests of symmetries and physics beyond standard models, intermediate energy physics, and spin technologies. Opening the meeting, T. Kinoshita reviewed the status of measurements of the anomalous magnetic moment (g-2) of the electron and the muon. The forthcoming experiment at Brookhaven (September 1991, page 23) will probe beyond the energy ranges open to existing electronpositron colliders. For example muon substructure will be opened up to 5 TeV and Ws to 2 TeV. R.L. Jaffe classified quark-parton distributions in terms of their spin dependence, pointing out their leftright attributes, and emphasized the importance of measuring transverse spin distributions through lepton pair production

  4. Popliteal artery entrapment syndrome.

    Science.gov (United States)

    Klooster, N J; Kitslaar, P; Janevski, B K

    1988-06-01

    Two patients with unilateral popliteal artery entrapment syndrome (PAES) are reported. The importance of diligence in angiographic diagnosis and recognition of the so-called "functional" PAES group as a separate entity are stressed. It is inferred from our material that a surgical approach for PAES is to be advocated since surgical release of the entrapment can lead to complete resolution of symptoms regardless of aetiology. PMID:2837797

  5. Popliteal artery entrapment syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Klooster, N.J.J.; Janevski, B.K.; Kitslaar, P.

    1988-06-01

    Two patients with unilateral popliteal artery entrapment syndrome (PAES) are reported. The importance of diligence in angiographic diagnosis and recognition of the so-called 'functional' PAES group as a separate entity are stressed. It is inferred from our material that a surgical approach for PAES is to be advocated since surgical release of the entrapment can lead to complete resolution of symptoms regardless of aetiology.

  6. Popliteal artery entrapment syndrome

    International Nuclear Information System (INIS)

    Two patients with unilateral popliteal artery entrapment syndrome (PAES) are reported. The importance of diligence in angiographic diagnosis and recognition of the so-called 'functional' PAES group as a separate entity are stressed. It is inferred from our material that a surgical approach for PAES is to be advocated since surgical release of the entrapment can lead to complete resolution of symptoms regardless of aetiology. (orig.)

  7. Gestational pulmonary arterial hypertension

    OpenAIRE

    Moll, Matthew; Payne, Julie G.; Tukey, Melissa H.; Farber, Harrison W.

    2015-01-01

    Pulmonary arterial hypertension (PAH) is a progressive disease marked by the irreversible pulmonary vascular changes of vasoconstriction, thrombosis, and proliferation of smooth muscle and endothelial cells. The untreated clinical course is characterized by progressive dyspnea and a median survival of less than 3 years. Many of these patients are of child-bearing age; however, pregnancy leads to physiologic changes that are particularly poorly tolerated in PAH, conferring a 30%–56% mortality....

  8. Idiopathic pulmonary arterial hypertension

    OpenAIRE

    Firth, Amy L.; Mandel, Jess; Yuan, Jason X.-J.

    2010-01-01

    Despite improved understanding of the pathobiology of pulmonary arterial hypertension (PAH), it remains a severe and progressive disease, usually culminating in right heart failure, significant morbidity and early mortality. Over the last decade, some major advances have led to substantial improvements in the management of PAH. Much of this progress was pioneered by work in animal models. Although none of the current animal models of pulmonary hypertension (PH) completely recapitulate the hum...

  9. Pulmonary arterial hypertension.

    OpenAIRE

    Montani, David; Günther, Sven; Dorfmüller, Peter; Perros, Frédéric; Girerd, Barbara; Garcia, Gilles; Jaïs, Xavier; Savale, Laurent; Artaud-Macari, Elise; Price, Laura; Humbert, Marc; Simonneau, Gérald; Sitbon, Olivier

    2013-01-01

    Pulmonary arterial hypertension (PAH) is a chronic and progressive disease leading to right heart failure and ultimately death if untreated. The first classification of PH was proposed in 1973. In 2008, the fourth World Symposium on PH held in Dana Point (California, USA) revised previous classifications. Currently, PH is devided into five subgroups. Group 1 includes patients suffering from idiopathic or familial PAH with or without germline mutations. Patients with a diagnosis of PAH should ...

  10. Spin-Wave Diode

    Science.gov (United States)

    Lan, Jin; Yu, Weichao; Wu, Ruqian; Xiao, Jiang

    2015-10-01

    A diode, a device allowing unidirectional signal transmission, is a fundamental element of logic structures, and it lies at the heart of modern information systems. The spin wave or magnon, representing a collective quasiparticle excitation of the magnetic order in magnetic materials, is a promising candidate for an information carrier for the next-generation energy-saving technologies. Here, we propose a scalable and reprogrammable pure spin-wave logic hardware architecture using domain walls and surface anisotropy stripes as waveguides on a single magnetic wafer. We demonstrate theoretically the design principle of the simplest logic component, a spin-wave diode, utilizing the chiral bound states in a magnetic domain wall with a Dzyaloshinskii-Moriya interaction, and confirm its performance through micromagnetic simulations. Our findings open a new vista for realizing different types of pure spin-wave logic components and finally achieving an energy-efficient and hardware-reprogrammable spin-wave computer.

  11. Spin physics at BNL

    International Nuclear Information System (INIS)

    Spin Physics at the Alternating Gradient Synchrotron (AGS) of Brookhaven National Laboratory is the most recent of new capabilities being explored at this facility. During the summer of 1984 the AGS accelerated beams of polarized protons to 16.5 GeV/c at 40% polarization to two experiments (E782, E785). These experiments; single spin asymmetry in inclusive polarized pp interactions; and spin-spin effects in polarized pp elastic scattering, operated at the highest polarized proton energy ever achieved by any accelerator in the world. These experiments are reviewed after the complementary spin physics program with unpolarized protons, and the future possibilities with a booster injector for the AGS and the secondary benefits of a Relativisitic Heavy Ion Collider (RHIC), are placed within the context of the present physics program

  12. Linerless label device and method

    KAUST Repository

    Binladen, Abdulkari

    2016-01-14

    This apparatus and method for applying a linerless label to an end user product includes a device with a printer for printing on a face surface of a linerless label, and a release coat applicator for applying a release coat to the face surface of the label; another device including an unwinder unit (103) to unwind a roll of printed linerless label; a belt (108); a glue applicator (102) for applying glue to the belt; a nip roller (106) for contacting and applying pressure to the face surface of the linerless label such that the glue on the belt transfers to the back surface of the linerless label; at least one slitting knife 105) positioned downstream the belt and a rewinder unit (104) positioned downstream the slitting knife; and a third device which die cuts and applies the linerless label to an end user object.

  13. Robotic coronary artery bypass for aberrant right coronary artery stenosis.

    Science.gov (United States)

    Chen, Kuan-chin Jean; Teefy, Patrick; Kiaii, Bob; Vezina, William C; Chu, Michael Wa

    2010-10-01

    Anomalous coronary arteries that course between the aorta and pulmonary artery are subject to compressive forces and can manifest angina, myocardial infarction and sudden death. The current report presents a young, female patient who presented with a short duration of severe, rapidly progressive angina despite optimal medical therapy. Combined computed tomography and myocardial perfusion scanning identified an anomalous dominant right coronary artery that appeared kinked at its origin between the aorta and main pulmonary artery. A robot-assisted right internal thoracic artery to right coronary artery bypass was performed, which was confirmed to be widely patent (FitzGibbon grade A) on routine intraoperative angiography. The procedure completely resolved the patient's angina symptoms. PMID:20931103

  14. Label-Guided Graph Exploration with Adjustable Ratio of Labels

    CERN Document Server

    Zhang, Meng; Tang, Jijun

    2012-01-01

    The graph exploration problem is to visit all the nodes of a connected graph by a mobile entity, e.g., a robot. The robot has no a priori knowledge of the topology of the graph or of its size. Cohen et al. \\cite{Ilcinkas08} introduced label guided graph exploration which allows the system designer to add short labels to the graph nodes in a preprocessing stage; these labels can guide the robot in the exploration of the graph. In this paper, we address the problem of adjustable 1-bit label guided graph exploration. We focus on the labeling schemes that not only enable a robot to explore the graph but also allow the system designer to adjust the ratio of the number of different labels. This flexibility is necessary when maintaining different labels may have different costs or when the ratio is pre-specified. We present 1-bit labeling (two colors, namely black and white) schemes for this problem along with a labeling algorithm for generating the required labels. Given an $n$-node graph and a rational number $\\rh...

  15. Synchronization of spin-transfer torque oscillators by spin pumping, inverse spin Hall, and spin Hall effects

    International Nuclear Information System (INIS)

    We have proposed a method to synchronize multiple spin-transfer torque oscillators based on spin pumping, inverse spin Hall, and spin Hall effects. The proposed oscillator system consists of a series of nano-magnets in junction with a normal metal with high spin-orbit coupling, and an accumulative feedback loop. We conduct simulations to demonstrate the effect of modulated charge currents in the normal metal due to spin pumping from each nano-magnet. We show that the interplay between the spin Hall effect and inverse spin Hall effect results in synchronization of the nano-magnets

  16. Summary of spin session talks

    International Nuclear Information System (INIS)

    Measurements of spin observables in scattering experiments have been useful to explore a wide variety of medium and high energy phenomena. Important new results were presented in each of the spin, combined hadron/spin and combined electrons and muons/spin sessions at this conference. Talks concerning spin effects in other sessions and in one of the hadron/spin parallel sessions are summarized by other speakers. The spin talks summarized in this paper are divided into four topics: tests of symmetry principles, lepton scattering, hadron scattering experiments, and new developments in spin-related technologies. 5 figs

  17. Spin Hall and spin Nernst effects in graphene with intrinsic and Rashba spin-orbit interactions

    Institute of Scientific and Technical Information of China (English)

    Zhu Guo-Bao

    2012-01-01

    The spin Hall and spin Nernst effects in graphene are studied based on Green's function formalism.We calculate intrinsic contributions to spin Hall and spin Nernst conductivities in the Kane-Mele model with various structures.When both intrinsic and Rashba spin-orbit interactions are present,their interplay leads to some characteristics of the dependence of spin Hall and spin Nernst conductivities on the Fermi level.When the Rashba spin-orbit interaction is smaller than intrinsic spin-orbit coupling,a weak kink in the conductance appears.The kink disappears and a divergence appears when the Rashba spin-orbit interaction enhances.When the Rashba spin-orbit interaction approaches and is stronger than intrinsic spin-orbit coupling,the divergence becomes more obvious.

  18. To Spin or Not to Spin?

    Institute of Scientific and Technical Information of China (English)

    Tina Boikos

    2008-01-01

    @@ The alarm has just gone off. Do I really have to get up? I wonder. Originally, signing up for an early-morning spinning class seemed like a good idea; it jump-starts the day with some well-needed exercise.

  19. Gluon Spin Contribution to The Nucleon Spin

    Energy Technology Data Exchange (ETDEWEB)

    Arash, Firooz, E-mail: farash@cic.aut.ac.i [Physics Department, Tafresh University, Tafresh (Iran, Islamic Republic of); Shahveh, Abolfazl [Physics Department, Tafresh University, Tafresh (Iran, Islamic Republic of); Taghavi-Shahri, Fateme [School of Particles and Accelerators, Institute for Research in Fundamental Sciences (IPM) P.O. Box 19395-5531, Tehran (Iran, Islamic Republic of)

    2010-10-15

    We have calculated {delta}g/g in the nucleon at all measured kinematics. The smallness of {delta}g/g in the measured kinematics should not be interpreted as the the gluon contribution to the nucleon spin is small. In fact the first moment of gluon polarization in the nucleon, {Delta}g(Q{sup 2}) can be sizable.

  20. Gluon Spin Contribution to The Nucleon Spin

    Science.gov (United States)

    Arash, Firooz; Shahveh, Abolfazl; Taghavi-Shahri, Fateme

    2010-10-01

    We have calculated δg/ g in the nucleon at all measured kinematics. The smallness of δg/ g in the measured kinematics should not be interpreted as the the gluon contribution to the nucleon spin is small. In fact the first moment of gluon polarization in the nucleon, Δ g( Q2) can be sizable.

  1. Gluon Spin Contribution to The Nucleon Spin

    International Nuclear Information System (INIS)

    We have calculated δg/g in the nucleon at all measured kinematics. The smallness of δg/g in the measured kinematics should not be interpreted as the the gluon contribution to the nucleon spin is small. In fact the first moment of gluon polarization in the nucleon, Δg(Q2) can be sizable.

  2. Labelled compounds. (Pt. B)

    International Nuclear Information System (INIS)

    Since the end of World War II there has been a tremendous increase in the number of compounds that have been synthesized with radioactive or stable isotopes. They have found application in many diverse fields, so much so, that hardly a single area in pure and applied science has not benefited. Not surprisingly it has been reflected in appearance of related publications. The early proceedings of the Symposia on Advances in Trace Methodology were soon followed by various Euratom sponsored meetings in which methods of preparing and storing labelled compounds featured prominently. In due course a resurgence of interest in stable isotopes, brought about by their greater availability (also lower cost) and partly by development of new techniques such as gas chromatography - mass spectrometry (gc-ms), led to the publication of proceedings of several successful conferences. More recently conferences dealing with the synthesis and applications of isotopes and isotopically labelled compounds have been established on a regular basis. In addition to the proceedings of conferences and journal publications individuals left their mark by producing definitive texts, usually on specific nuclides. Only the classic two volume publication of Murray and Williams (Organic syntheses with isotopes, New York 1985), now over 30 years old and out of print, attempted to do justice to several nuclides. With the large amount of work that has been undertaken since then it seems unlikely that an updated edition could be produced. The alternative strategy was to ask scientists currently active to review specific areas and this is the approach adopted in the present series of monographs. In this way it is intended to cover the broad advances that have been made in the synthesis and applications of isotopes and isotopically labelled compounds in the physical and biomedical sciences. (author). refs.; figs.; tabs

  3. Assessment of the accumulation of technetium-99m labelled leukocytes in the treatment of the infections of vascular prosthesis

    International Nuclear Information System (INIS)

    The purpose of this is to evaluate the accumulation of technetium-99m-labelled leukocytes after change of vascular, dacron and infected prosthetic graft in arterial homo grafts harvested from multiorgan-procurement - with own computer program. In this paper 11 cases of aorto-ilio-femoral graft infection treated by the replacement of infected prosthesis with fresh, bifurcated, arterial homografts is presented. In all patients clinical investigations revealed vascular prosthesis infection with the rupture of vascular anastomoses between the prosthesis' branch and wall of artery that resulted with hemorrhage. The Duplex- Doppler ultrasound and the scintigraphy with use of technetium-labeled leucocytes were used in the diagnostic trial of infection and of the healing process of the arterial homografts.The area of the accumulation of 99mTc labelled leukocytes was evaluated with own computer programs. Positive clinical effect was obtained in all patients.The regression of infection after in situ replacement of the synthetic prosthesis with homograft was presented with the scintigraphic examination: in these patients the area of leukocytes accumulation decreased from 34±3 cm2 to 9±2cm2. The use of scintigraphy with 99mTc labelled leukocytes to evaluate the healing process of the arterial homografts in therapy of the prosthetic graft is a the accumulation of leucocytes is facilitation in the monitoring of regression of infection. (author)

  4. Waisda?: video labeling game

    OpenAIRE

    Hildebrand, Michiel; Brinkerink, M.; Gligorov, R.; Steenbergen, Van; Huijkman, J.; Oomen, J.

    2013-01-01

    The Waisda? video labeling game is a crowsourcing tool to collect user-generated metadata for video clips. It follows the paradigm of games-with-a-purpose, where two or more users play against each other by entering tags that describe the content of the video. Players score points by entering the same tags as one of the other players. As a result each video that is played in the game is annotated with tags that are anchored to a time point in the video. Waisda? has been deployed in two projec...

  5. From Label to Practice

    DEFF Research Database (Denmark)

    Byrkjeflot, Haldor; Strandgaard, Jesper; Svejenova, Silviya

    2013-01-01

    This article examines the process of creation of new Nordic cuisine (NNC) as a culinary innovation, focusing on the main stages, actors, and mechanisms that shaped the new label and its practices and facilitated its diffusion in the region and internationally. Fast-paced diffusion was possible...... because NNC was conceived as an identity movement, triggered by active involvement of entrepreneurial leaders from the culinary profession, high-profile political supporters, legitimating scientists, disseminating media, and interpreting audiences. It was facilitated by three mechanisms: First, the use of...

  6. Labeled bile acids

    International Nuclear Information System (INIS)

    A general short procedure for the introduction of 13C to the side chain of bile acids is described. Suitable (Z)-pregn-17(20)-enes are key intermediates, while the isotope is introduced by an ene reaction with [1,2,3-13C3]-methyl propiolate. For the labeling with tritium, the unlabeled product of the ene synthesis, a Δsup(5,16,22)-triene was saturated selectively at 16,17 and 22,23 with tritium gas. (author)

  7. A Food Labeling

    Science.gov (United States)

    ... " ﻗﺎﻧﻮن اﻟﺒﻄﺎﻗﺎت واﻟﺘﻮﻋﻴﺔ اﻟﻐﺬاﺋﻴﺔ " [ Nutrition Labeling and Education Act ... ﻟﻠﻌﺼﻴﺮ اﻟﻤﻜﻮن ﺑﺈﺿﺎﻓﺔ اﻟﻤﺎء إﻟﻰ ﺧﻼﺻﺔ ﻣﺮآﺰة : ﻳﺠﺮى اﻟﺤﺴﺎب ﻣﻦ ﺟﺪول Brix ﻓﻲ 21 CFR 101.30(h)(1) ...

  8. Towards Multi Label Text Classification through Label Propagation

    Directory of Open Access Journals (Sweden)

    Shweta C. Dharmadhikari

    2012-06-01

    Full Text Available Classifying text data has been an active area of research for a long time. Text document is multifaceted object and often inherently ambiguous by nature. Multi-label learning deals with such ambiguous object. Classification of such ambiguous text objects often makes task of classifier difficult while assigning relevant classes to input document. Traditional single label and multi class text classification paradigms cannot efficiently classify such multifaceted text corpus. Through our paper we are proposing a novel label propagation approach based on semi supervised learning for Multi Label Text Classification. Our proposed approach models the relationship between class labels and also effectively represents input text documents. We are using semi supervised learning technique for effective utilization of labeled and unlabeled data for classification. Our proposed approach promises better classification accuracy and handling of complexity and elaborated on the basis of standard datasets such as Enron, Slashdot and Bibtex.

  9. Arterial responses during migraine headache

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Olesen, J;

    1990-01-01

    The superficial temporal artery has been thought to be the main focus of pain during migraine attacks, but its diameter has never been measured directly. The use of a new, high-resolution ultrasound machine to measure arterial size in 25 migraine patients with unilateral head pain showed that the...... lumen was wider on the painful than on the non-painful side during a migraine attack. The diameters of both radial arteries and the temporal artery on the non-painful side were smaller during than between attacks. The generalised vasoconstriction was not shared by the temporal artery on the affected...... side, which suggests a local vasodilatory response. The findings suggest that cephalic arteries may play a role in migraine pathogenesis....

  10. True aneurysm of brachial artery.

    Science.gov (United States)

    Hudorović, Narcis; Lovričević, Ivo; Franjić, Dario Bjorn; Brkić, Petar; Tomas, Davor

    2010-10-01

    True upper extremity peripheral artery aneurysms are a rarely encountered arterial disorder. Following computer-tomography angiographic (CT-a) imaging examination, true saccular aneurysm, originating from the left brachial artery was diagnosed in the 77-year-old female without history of trauma. The aneurysm was resected by surgical intervention, and primary repair of the brachial artery was performed by interposition of a part of great saphenous vein harvested from the left groin and creation of two end-to-end anastomoses between interposition graft and previously resected part of brachial artery. No complication was observed during the follow-up. Surgical intervention for upper extremity aneurysms should be initiated without delay. Factors combined with minimal morbidity associated with repair suggest that surgical repair should be performed routinely for true upper extremity arterial aneurysms. PMID:20865459

  11. Resonant Tunneling Spin Pump

    Science.gov (United States)

    Ting, David Z.

    2007-01-01

    The resonant tunneling spin pump is a proposed semiconductor device that would generate spin-polarized electron currents. The resonant tunneling spin pump would be a purely electrical device in the sense that it would not contain any magnetic material and would not rely on an applied magnetic field. Also, unlike prior sources of spin-polarized electron currents, the proposed device would not depend on a source of circularly polarized light. The proposed semiconductor electron-spin filters would exploit the Rashba effect, which can induce energy splitting in what would otherwise be degenerate quantum states, caused by a spin-orbit interaction in conjunction with a structural-inversion asymmetry in the presence of interfacial electric fields in a semiconductor heterostructure. The magnitude of the energy split is proportional to the electron wave number. Theoretical studies have suggested the possibility of devices in which electron energy states would be split by the Rashba effect and spin-polarized currents would be extracted by resonant quantum-mechanical tunneling.

  12. CNN: Single-label to Multi-label

    OpenAIRE

    Wei, Yunchao; Xia, Wei; Huang, Junshi; Ni, Bingbing; Dong, Jian; Zhao, Yao; Yan, Shuicheng

    2014-01-01

    Convolutional Neural Network (CNN) has demonstrated promising performance in single-label image classification tasks. However, how CNN best copes with multi-label images still remains an open problem, mainly due to the complex underlying object layouts and insufficient multi-label training images. In this work, we propose a flexible deep CNN infrastructure, called Hypotheses-CNN-Pooling (HCP), where an arbitrary number of object segment hypotheses are taken as the inputs, then a shared CNN is...

  13. Triple spontaneous cervical artery dissection

    International Nuclear Information System (INIS)

    A 39-year-old healthy man had several transient ischaemic attacks suggesting left internal carotid artery (ICA) occlusion. There were no vascular risk factors and no preceding trauma. Colour-coded duplex sonography suggested a pseudo-occlusion of the left ICA, and cerebral angiography demonstrated dissection of the left ICA and both vertebral arteries. Angiography 6 months later was completely normal. This underlines the importance of four vessel angiography in young patients with dissections of cervical arteries. (orig.)

  14. The right hepatic artery syndrome

    Institute of Scientific and Technical Information of China (English)

    Kazumi Miyashita; Katsuya Shiraki; Takeshi Ito; Hiroki Taoka; Takeshi Nakano

    2005-01-01

    Various benign and malignant conditions could cause biliary obstruction. Compression of extrahepatic bile duct (EBD) by right hepatic artery was reported as a right hepatic artery syndrome but all cases were compressed EBD from stomach side. Our case compressed from dorsum was not yet reported, so it was thought to be a very rare case. We present here the first case of bile duct obstruction due to the compression of EBD from dorsum by right hepatic artery.

  15. Electron spin decoherence in nuclear spin baths and dynamical decoupling

    International Nuclear Information System (INIS)

    We introduce the quantum theory of the electron spin decoherence in a nuclear spin bath and the dynamical decoupling approach for protecting the electron spin coherence. These theories are applied to various solid-state systems, such as radical spins in molecular crystals and NV centers in diamond.

  16. Representation of Spin Group Spin(p, q)

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The representation (&)(p, q) of spin group Spin(p, q) in any dimensional space is given by induction, and the relation between two representations, which are obtained in two kinds of inductions from Spin(p, q) to Spin(p + 1, q + 1)are studied.

  17. SPIN Tutorial: How to Become a SPIN Doctor

    NARCIS (Netherlands)

    Ruys, T.C.; Bosnacki, D.; Leue, S.

    2002-01-01

    SPIN is a model checker for the verification of software systems. SPIN uses a high level language called PROMELA to specify systems descriptions. The goal of this tutorial is to introduce novice users to both PROMELA and SPIN. The tutorial itself is divided into two parts. The BASIC SPIN part is tar

  18. Quantifying Spin Hall Angles from Spin Pumping: Experiments and Theory

    NARCIS (Netherlands)

    Mosendz, O.; Pearson, J.E.; Fradin, F.Y.; Bauer, G.E.W.; Bader, S.D.; Hoffmann, A.

    2010-01-01

    Spin Hall effects intermix spin and charge currents even in nonmagnetic materials and, therefore, ultimately may allow the use of spin transport without the need for ferromagnets. We show how spin Hall effects can be quantified by integrating Ni80Fe20|normal metal (N) bilayers into a coplanar wavegu

  19. Spin drift and spin diffusion currents in semiconductors

    Directory of Open Access Journals (Sweden)

    M Idrish Miah

    2008-01-01

    Full Text Available On the basis of a spin drift-diffusion model, we show how the spin current is composed and find that spin drift and spin diffusion contribute additively to the spin current, where the spin diffusion current decreases with electric field while the spin drift current increases, demonstrating that the extension of the spin diffusion length by a strong field does not result in a significant increase in spin current in semiconductors owing to the competing effect of the electric field on diffusion. We also find that there is a spin drift-diffusion crossover field for a process in which the drift and diffusion contribute equally to the spin current, which suggests a possible method of identifying whether the process for a given electric field is in the spin drift or spin diffusion regime. Spin drift-diffusion crossover fields for GaAs are calculated and are found to be quite small. We derive the relations between intrinsic spin diffusion length and the spin drift-diffusion crossover field of a semiconductor for different electron statistical regimes. The findings resulting from this investigation might be important for semiconductor spintronics.

  20. Label and Label-Free Detection Techniques for Protein Microarrays

    Directory of Open Access Journals (Sweden)

    Amir Syahir

    2015-04-01

    Full Text Available Protein microarray technology has gone through numerous innovative developments in recent decades. In this review, we focus on the development of protein detection methods embedded in the technology. Early microarrays utilized useful chromophores and versatile biochemical techniques dominated by high-throughput illumination. Recently, the realization of label-free techniques has been greatly advanced by the combination of knowledge in material sciences, computational design and nanofabrication. These rapidly advancing techniques aim to provide data without the intervention of label molecules. Here, we present a brief overview of this remarkable innovation from the perspectives of label and label-free techniques in transducing nano‑biological events.

  1. Arterial mapping of lower limbs

    International Nuclear Information System (INIS)

    A bibliographic review is realized in the arterial mapping of lower limbs by ultrasonographic. The physical properties of the Doppler effect applied to diagnostic ultrasound are described. The anatomical characteristics of the general arterial system and specifically of the lower limbs arterial system are mentioned. Pathologies of the ischemic arterial disease of lower limbs are explained. The study characteristics of lower limbs arterial mapping are documented to determine its importance as appropriate method for the assessment of lower limb ischemia. An adequate arterial mapping of lower limbs is recognized in atherosclerotic ischemic disease as a reliable initial method alternative to arteriography. Arteriography is considered as reference pattern for therapeutic decision making in patients with critical ischemia of the lower limbs. Non-invasive methods to assess the arterial system of lower limbs has evidenced the advantages of the arterial mapping with Doppler, according to the consulted literature. The combination morphological and hemodynamic information has been possible and a map of the explored zone is made. The arterial mapping by ultrasonography has offered similar reliability to angiography

  2. SPINning parallel systems software

    International Nuclear Information System (INIS)

    We describe our experiences in using Spin to verify parts of the Multi Purpose Daemon (MPD) parallel process management system. MPD is a distributed collection of processes connected by Unix network sockets. MPD is dynamic processes and connections among them are created and destroyed as MPD is initialized, runs user processes, recovers from faults, and terminates. This dynamic nature is easily expressible in the Spin/Promela framework but poses performance and scalability challenges. We present here the results of expressing some of the parallel algorithms of MPD and executing both simulation and verification runs with Spin

  3. Higher spin cosmology

    Science.gov (United States)

    Krishnan, Chethan; Raju, Avinash; Roy, Shubho; Thakur, Somyadip

    2014-02-01

    We construct cosmological solutions of higher spin gravity in 2+1 dimensional de Sitter space. We show that a consistent thermodynamics can be obtained for their horizons by demanding appropriate holonomy conditions. This is equivalent to demanding the integrability of the Euclidean boundary conformal field theory partition function, and it reduces to Gibbons-Hawking thermodynamics in the spin-2 case. By using the prescription of Maldacena, we relate the thermodynamics of these solutions to those of higher spin black holes in AdS3.

  4. Spins in chemistry

    CERN Document Server

    McWeeny, Roy

    2004-01-01

    Originally delivered as a series of lectures, this volume systematically traces the evolution of the ""spin"" concept from its role in quantum mechanics to its assimilation into the field of chemistry. Author Roy McWeeny presents an in-depth illustration of the deductive methods of quantum theory and their application to spins in chemistry, following the path from the earliest concepts to the sophisticated physical methods employed in the investigation of molecular structure and properties. Starting with the origin and development of the spin concept, the text advances to an examination of sp

  5. Quantum Spin Hall Effect

    Energy Technology Data Exchange (ETDEWEB)

    Bernevig, B.Andrei; Zhang, Shou-Cheng; /Stanford U., Phys. Dept.

    2010-01-15

    The quantum Hall liquid is a novel state of matter with profound emergent properties such as fractional charge and statistics. Existence of the quantum Hall effect requires breaking of the time reversal symmetry caused by an external magnetic field. In this work, we predict a quantized spin Hall effect in the absence of any magnetic field, where the intrinsic spin Hall conductance is quantized in units of 2 e/4{pi}. The degenerate quantum Landau levels are created by the spin-orbit coupling in conventional semiconductors in the presence of a strain gradient. This new state of matter has many profound correlated properties described by a topological field theory.

  6. Spinning Q-Balls

    OpenAIRE

    Volkov, Mikhail S.; Woehnert, Erik

    2002-01-01

    We present numerical evidence for the existence of spinning generalizations for non-topological Q-ball solitons in the theory of a complex scalar field with a non-renormalizable self-interaction. To the best of our knowledge, this provides the first explicit example of spinning solitons in 3+1 dimensional Minkowski space. In addition, we find an infinite discrete family of radial excitations of non-rotating Q-balls, and construct also spinning Q-balls in 2+1 dimensions.

  7. Frustrated spin systems

    CERN Document Server

    2013-01-01

    This book covers all principal aspects of currently investigated frustrated systems, from exactly solved frustrated models to real experimental frustrated systems, going through renormalization group treatment, Monte Carlo investigation of frustrated classical Ising and vector spin models, low-dimensional systems, spin ice and quantum spin glass. The reader can - within a single book - obtain a global view of the current research development in the field of frustrated systems.This new edition is updated with recent theoretical, numerical and experimental developments in the field of frustrated

  8. Spin transport and spin dephasing in zinc oxide

    OpenAIRE

    Althammer, Matthias; Karrer-Müller, Eva-Maria; Goennenwein, Sebastian T. B.; Opel, Matthias; Gross, Rudolf

    2012-01-01

    The wide bandgap semiconductor ZnO is interesting for spintronic applications because of its small spin-orbit coupling implying a large spin coherence length. Utilizing vertical spin valve devices with ferromagnetic electrodes (TiN/Co/ZnO/Ni/Au), we study the spin-polarized transport across ZnO in all-electrical experiments. The measured magnetoresistance agrees well with the prediction of a two spin channel model with spin-dependent interface resistance. Fitting the data yields spin diffusio...

  9. Spin transfer torque with spin diffusion in magnetic tunnel junctions

    KAUST Repository

    Manchon, Aurelien

    2012-08-09

    Spin transport in magnetic tunnel junctions in the presence of spin diffusion is considered theoretically. Combining ballistic tunneling across the barrier and diffusive transport in the electrodes, we solve the spin dynamics equation in the metallic layers. We show that spin diffusion mixes the transverse spin current components and dramatically modifies the bias dependence of the effective spin transfer torque. This leads to a significant linear bias dependence of the out-of-plane torque, as well as a nonconventional thickness dependence of both spin torque components.

  10. MRI and MR angiography of vertebral artery dissection

    Energy Technology Data Exchange (ETDEWEB)

    Mascalchi, M. [Cattedra di Radiologia, Universita di Pisa (Italy); Bianchi, M.C. [Servizio di Neuroradiologia, Ospedale S. Chiara, Pisa (Italy); Mangiafico, S. [Servizio di Neuroradiologia, Ospedale di Careggi, Firenze (Italy); Ferrito, G. [Servizio di Neuroradiologia, Ospedali Riuniti, Livorno (Italy); Puglioli, M. [Servizio di Neuroradiologia, Ospedale S. Chiara, Pisa (Italy); Marin, E. [Servizio di Radiologia, Ospedale S. M. Nuova, Firenze (Italy); Mugnai, S. [Clinica Neurologica, Universita di Firenze (Italy); Canapicchi, R. [Servizio di Neuroradiologia, Ospedale S. Chiara, Pisa (Italy); Quilici, N. [Servizio di Neuroradiologia, Ospedali Riuniti, Livorno (Italy); Inzitari, D. [Clinica Neurologica, Universita di Firenze (Italy)

    1997-05-01

    A review of 4,500 angiograms yielded 11 patients with dissection of the vertebral arteries who had MRI and (in 4 patients) MR angiography (MRA) in the acute phase of stroke. One patient with incidental discovery at arteriography of asymptomatic vertebral artery dissection and two patients with acute strokes with MRI and MRA findings consistent with vertebral artery dissection were included. Dissection occurred after neck trauma or chiropractic manipulation in 4 patients and was spontaneous in 10. Dissection involved the extracranial vertebral artery in 9 patients, the extra-intracranial junction in 1, and the intracranial artery in 4. MRI demonstrated infarcts in the brain stem, cerebellum, thalamus or temporo-occipital regions in 7 patients with extra- or extra-intracranial dissections and a solitary lateral medullary infarct in 4 patients (3 with intracranial and 1 with extra-intracranial dissection). In 2 patients no brain abnormality related to vertebral artery dissection was found and in one MRI did not show subarachnoid haemorrhage revealed by CT. Intramural dissecting haematoma appeared as crescentic or rounded high signal on T1-weighted images in 10 patients examined 3-20 days after the onset of symptoms. The abnormal vessel stood out in the low signal cerebrospinal fluid in intracranial dissections, whereas it was more difficult to detect in extracranial dissections because of the intermediate-to-high signal of the normal perivascular structures and slow flow proximal and distal to the dissection. In two patients examined within 36 h of the onset, mural thickening was of intermediate signal intensity on T1-weighted images and high signal on spin-density and T2-weighted images. MRA showed abrupt stenosis in 2 patients and disappearance of flow signal at and distal to the dissection in 5. Follow-up arteriography, MRI or MRA showed findings consistent with occlusion of the dissected vessel in 6 of 8 patients. (orig.). With 7 figs., 3 tabs.

  11. MRI and MR angiography of vertebral artery dissection

    International Nuclear Information System (INIS)

    A review of 4,500 angiograms yielded 11 patients with dissection of the vertebral arteries who had MRI and (in 4 patients) MR angiography (MRA) in the acute phase of stroke. One patient with incidental discovery at arteriography of asymptomatic vertebral artery dissection and two patients with acute strokes with MRI and MRA findings consistent with vertebral artery dissection were included. Dissection occurred after neck trauma or chiropractic manipulation in 4 patients and was spontaneous in 10. Dissection involved the extracranial vertebral artery in 9 patients, the extra-intracranial junction in 1, and the intracranial artery in 4. MRI demonstrated infarcts in the brain stem, cerebellum, thalamus or temporo-occipital regions in 7 patients with extra- or extra-intracranial dissections and a solitary lateral medullary infarct in 4 patients (3 with intracranial and 1 with extra-intracranial dissection). In 2 patients no brain abnormality related to vertebral artery dissection was found and in one MRI did not show subarachnoid haemorrhage revealed by CT. Intramural dissecting haematoma appeared as crescentic or rounded high signal on T1-weighted images in 10 patients examined 3-20 days after the onset of symptoms. The abnormal vessel stood out in the low signal cerebrospinal fluid in intracranial dissections, whereas it was more difficult to detect in extracranial dissections because of the intermediate-to-high signal of the normal perivascular structures and slow flow proximal and distal to the dissection. In two patients examined within 36 h of the onset, mural thickening was of intermediate signal intensity on T1-weighted images and high signal on spin-density and T2-weighted images. MRA showed abrupt stenosis in 2 patients and disappearance of flow signal at and distal to the dissection in 5. Follow-up arteriography, MRI or MRA showed findings consistent with occlusion of the dissected vessel in 6 of 8 patients. (orig.). With 7 figs., 3 tabs

  12. Modeling the effects of labeling

    DEFF Research Database (Denmark)

    Juhl, Hans Jørn; Fjord, Thomas Ahle; Poulsen, Carsten Stig

    A new approach to evaluate the consequences of labeling is presented and applied to test the potential effect of a label on fresh fish. Labeling effects on quality perceptions and overall quality are studied. The empirical study is based on an experimental design and nearly 500 respondents partic...... participated in an in home test. The results indicate that catch time alone is not enough to work as an efficient predictor of actual perceived quality.......A new approach to evaluate the consequences of labeling is presented and applied to test the potential effect of a label on fresh fish. Labeling effects on quality perceptions and overall quality are studied. The empirical study is based on an experimental design and nearly 500 respondents...

  13. Edge colouring by total labellings

    DEFF Research Database (Denmark)

    Brandt, Stephan; Rautenbach, D.; Stiebitz, M.;

    2010-01-01

    We introduce the concept of an edge-colouring total k-labelling. This is a labelling of the vertices and the edges of a graph G with labels 1, 2, ..., k such that the weights of the edges define a proper edge colouring of G. Here the weight of an edge is the sum of its label and the labels of its...... two endvertices. We define χ (G) to be the smallest integer k for which G has an edge-colouring total k-labelling. This parameter has natural upper and lower bounds in terms of the maximum degree Δ of G : ⌈ (Δ + 1) / 2 ⌉ ≤ χ (G) ≤ Δ + 1. We improve the upper bound by 1 for every graph and prove χ (G...

  14. Intra-Arterial Radionuclide Therapies for Liver Tumors.

    Science.gov (United States)

    Bozkurt, Murat Fani; Salanci, Bilge Volkan; Uğur, Ömer

    2016-07-01

    Intra-arterial radionuclide therapies serve essentially as internal radiation treatment options for both primary and metastatic liver tumors, which imply delivering implantable radioactive microspheres into branches of hepatic arteries that feed liver tumors to provide a high dose of targeted radiation to tumor tissue, while sparing the healthy liver tissue from hazardous effects of radiation. The principle of this therapeutic option depends on the unique preferential arterial supply of malignant liver tumors in contrast with mostly portal venous supply of normal hepatocytes as well as excess amount of arterial neovascularization in the tumor bed. Therefore, intra-arterial radionuclide therapy can provide very high radiation exposure to tumor tissue, which is impossible to reach with external radiation therapy due to serious side effects and moreover, radiation can be targeted to tumor tissue selectively with less side effects. Yttrium-90 (Y-90), a high-energetic beta emitter is the most preferred radionuclide, which is used to label microspheres. Two types of Y-90 microspheres are commercially available that are made of resin and glass. Many studies in the literature have demonstrated that Y-90 microsphere therapy is an efficient and safe locoregional therapeutic option for unresectable primary and metastatic liver tumors such as hepatocellular carcinoma and liver metastases from colorectal cancer and breast cancer as well as neuroendocrine tumors. Furthermore, limited number of studies has reported its use in some relatively uncommon metastatic liver tumors from melanoma, pancreatic, renal, and lung cancer. Besides Y-90 microspheres, Iodine-131 lipiodol, Rhenium-188 lipiodol, Rhenium-188 microspheres, Holmium-166 chitosan, and Holmium-166 microspheres have been introduced as alternative radiopharmaceuticals for intra-arterial therapy for liver tumors. PMID:27237442

  15. ANALYSIS ON THE SPINNING FORCES IN FLEXIBLE SPINNING OF CONES

    Institute of Scientific and Technical Information of China (English)

    Xia Qinxiang; Susumu Shima

    2003-01-01

    Flexible spinning is a new type of spinning process where spin-forming is performed without using a mandrel. Combining shearing and rolling processes, the calculation formulas of thespinning forces in flexible spinning of cones is presented. The effects of the main processing parameters, such as gripping force G applied to the blank by the inner roller, the feed rate of rollersfand the roundness radius of outer roller ro, on the spinning forces are analyzed experimentally and theoretically.

  16. Proposal for a spin MOSFET based on spin gapless semiconductors

    OpenAIRE

    Graziosi, Patrizio

    2016-01-01

    We propose a spintronic metal oxide semiconductor field effect transistor (spin MOSFET) where a spin gapless semiconductor (SGS) constitutes the channel and the drain is a ferromagnetic metal. SGS exhibit a non-zero band gap in only one of the spin sub-bands and feature complete spin polarization at finite temperature. We present an analytical model of the device and comment the properties relevant for devices applications. Our results boost SGS as a new paradigm for the spin MOSFET concept.

  17. [The single coronary artery].

    Science.gov (United States)

    Godart, F; Berzin, B; Rihani, R; Pecheux, M; Dutoit, A

    1992-04-01

    Single coronary artery is a fairly rare entity which may nevertheless be found in 0.4 per cent of coronary arteriograms. The authors report 3 cases seen in 2 departments of cardiology. In each patient, despite the existence of definite cardiovascular risk factors, this distribution was a factor worsening coronary ischemia, leading to complete thrombosis in one case. Although most often a chance discovery, a review of the literature justifies the attribution to this anomaly of the onset of angina, infarction or even sudden death. PMID:1642437

  18. Patent arterial duct

    OpenAIRE

    Martin Robin P; Elmasry Ola A; Forsey Jonathan T

    2009-01-01

    Abstract Patent arterial duct (PAD) is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavi...

  19. Aggregating Labels in Crowdsourcing Data

    OpenAIRE

    Priisalu, Maria; Grey, Francois; Segal, Ben

    2015-01-01

    Project Specification Crowdsourcing is gaining popularity in academia with the launch of crowdsourcing platforms such as Crowdcrafting [Lombraña, 2015] and GeoTagX [UNOSAT, 2015]. There have been a number of proposed algorithms for the aggregation of true labels and a confusion matrix from crowdsourced labels for ordinal, nominal and binary labels. The work here consists of an implementation of the Dawid Skene [Dawid 1979] adaptation of the Expectation Maximization algorithm [D...

  20. Classification and Labelling for Biocides

    OpenAIRE

    Rubbiani, Maristella

    2015-01-01

    CLP and biocides The EU Regulation (EC) No 1272/2008 on Classification, Labelling and Packaging of Substances and Mixtures, the CLP-Regulation, entered into force on 20th January, 2009. Since 1st December, 2010 the classification, labelling and packaging of substances has to comply with this Regulation. For mixtures, the rules of this Regulation are mandatory from 1st June, 2015; this means that until this date classification, labelling and packaging could either be carried out according to D...

  1. Parent Artery Occlusion for Posterior Cerebral Artery Aneurysms

    OpenAIRE

    Hoya, K.; Nagaishi, M.; Yoshimoto, Y.; Morikawa, E.; H. Takahashi(NASA Goddard Space Flight Center, Greenbelt, USA)

    2006-01-01

    We review four cases of posterior cerebral artery (PCA) aneurysm, of which three showed intolerance of parent artery occlusion. In two, balloon test occlusion (BTO) indicated poor opaci- fication of the PCA branches from the anastomoses, and therefore, permanent occlusion was not attempted.

  2. Association between internal carotid artery dissection and arterial tortuosity

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Piga, Mario [Azienda Ospedaliero Universitaria (A.O.U.), Department of Radiology, Monserrato, Cagliari (Italy); Argiolas, Giovanni Maria; Siotto, Paolo [Azienda Ospedaliero Brotzu (A.O.B.), Department of Radiology, di Cagliari (Italy); Sumer, Suna; Wintermark, Max [Neuroradiology Division, Neuroradiology, UVA Department of Radiology, Charlottesville, VA (United States); Raz, Eytan [New York University School of Medicine, Department of Radiology, New York, NY (United States); Sapienza University of Rome, Department of Neurology and Psychiatry, Rome (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria (A.O.U.), Department of Vascular Surgery, di Cagliari (Italy)

    2014-10-18

    Carotid artery dissection is an important cause of ischemic stroke in all age groups, particularly in young patients. The purpose of this work was to assess whether there is an association between the presence of an internal carotid artery dissection (ICAD) and the arterial tortuosity. This study considered 124 patients (72 males and 52 females; median age 57 years) with CT/MR diagnosis of ICAD of the internal carotid artery were considered in this multi-centric retrospective study. The arterial tortuosity was evaluated and, when present, was categorized as elongation, kinking, or coiling. For each patient, both the right and left sides were considered for a total number of 248 arteries in order to have the same number of cases and controls. Fisher's exact test was applied to test the association between elongation, kinking, coiling, dissection, and the side affected by CAD. Fisher's exact test showed a statistically significant association between the ICAD and kinking (p = 0.0089) and coiling (p = 0.0251) whereas no statistically significant difference was found with arterial vessel elongation (p = 0.444). ICAD was more often seen on the left side compared to the right (p = 0.0001). These results were confirmed using both carotid arteries of the same patient as dependent parameter with p = 0.0012, 0.0129, and 0.3323 for kinking, coiling, and elongation, respectively. The presence of kinking and coiling is associated with ICAD. (orig.)

  3. Dual anterior descending coronary artery associated with coronary artery disease

    Directory of Open Access Journals (Sweden)

    Siqueira Luciane da L. V.

    2003-01-01

    Full Text Available The patient is a male with risk factors for coronary artery disease, who was referred for cardiac catheterization after acute myocardial infarction in the inferior wall. The patient underwent transluminal coronary angioplasty in the right coronary artery with successful stent implantation.

  4. Co-Labeling for Multi-View Weakly Labeled Learning.

    Science.gov (United States)

    Xu, Xinxing; Li, Wen; Xu, Dong; Tsang, Ivor W

    2016-06-01

    It is often expensive and time consuming to collect labeled training samples in many real-world applications. To reduce human effort on annotating training samples, many machine learning techniques (e.g., semi-supervised learning (SSL), multi-instance learning (MIL), etc.) have been studied to exploit weakly labeled training samples. Meanwhile, when the training data is represented with multiple types of features, many multi-view learning methods have shown that classifiers trained on different views can help each other to better utilize the unlabeled training samples for the SSL task. In this paper, we study a new learning problem called multi-view weakly labeled learning, in which we aim to develop a unified approach to learn robust classifiers by effectively utilizing different types of weakly labeled multi-view data from a broad range of tasks including SSL, MIL and relative outlier detection (ROD). We propose an effective approach called co-labeling to solve the multi-view weakly labeled learning problem. Specifically, we model the learning problem on each view as a weakly labeled learning problem, which aims to learn an optimal classifier from a set of pseudo-label vectors generated by using the classifiers trained from other views. Unlike traditional co-training approaches using a single pseudo-label vector for training each classifier, our co-labeling approach explores different strategies to utilize the predictions from different views, biases and iterations for generating the pseudo-label vectors, making our approach more robust for real-world applications. Moreover, to further improve the weakly labeled learning on each view, we also exploit the inherent group structure in the pseudo-label vectors generated from different strategies, which leads to a new multi-layer multiple kernel learning problem. Promising results for text-based image retrieval on the NUS-WIDE dataset as well as news classification and text categorization on several real-world multi

  5. A nucleotide-independent cyclic nitroxide label for monitoring segmental motions in nucleic acids

    International Nuclear Information System (INIS)

    Spin labels, which are chemically stable radicals attached at specific sites of a bio-molecule, enable investigations on structure and dynamics of proteins and nucleic acids using techniques such as site-directed spin labeling and paramagnetic NMR. Among spin labels developed, the class of rigid labels have limited or no independent motions between the radical bearing moiety and the target, and afford a number of advantages in measuring distances and monitoring local dynamics within the parent bio-molecule. However, a general method for attaching a rigid label to nucleic acids in a nucleotide-independent manner has not been reported. We developed an approach for installing a nearly rigid nitroxide spin label, designated as R5c, at a specific site of the nucleic acid backbone in a nucleotide-independent manner. The method uses a post-synthesis approach to covalently attach the nitroxide moiety in a cyclic fashion to phosphorothioate groups introduced at two consecutive nucleotides of the target strand. R5c-labeled nucleic acids are capable of pairing with their respective complementary strands, and the cyclic nature of R5c attachment significantly reduced independence motions of the label with respect to the parent duplex, although it may cause distortion of the local environment at the site of labeling. R5c yields enhanced sensitivity to the collective motions of the duplex, as demonstrated by its capability to reveal changes in collective motions of the substrate recognition duplex of the 120-kDa Tetrahymena group I ribozyme, which elude detection by a flexible label. The cyclic R5c nitroxide can be efficiently attached to a target nucleic acid site using a post-synthetic coupling approach conducted under mild biochemical conditions, and serves as a viable label for experimental investigation of segmental motions in nucleic acids, including large folded RNAs. The online version of this article (doi:10.1186/s13628-015-0019-5) contains supplementary material, which

  6. Sensitivity and specificity of pulsatility index umbilical artery and middle cerebral artery in detecting intra uterine growth restriction

    International Nuclear Information System (INIS)

    To determine the sensitivity and specificity of the pulsatile index in umbilical artery (PI-UA) and pulsatile index in middle cerebral artery (PI-MCA) in detecting IUGR by comparing it with the birth weight. Study Design: Validation Study. Place and Duration of Study: Study was conducted in Department of Radiology, Military Hospital and Combined Military Hospital Rawalpindi, which was equipped with the (Aloka SSD-5500) using 3.5 MHz transducer after seeking permission from hospital ethical committee from 1st January 2010 to 10th January 2010. Subjects and Methods: Two hundred and fifty pregnant women with IUGR in third trimester were included in the study. Ultrasound estimation of fetal weight (using fetal biometry) below 10th percentile for that gestational age was labeled as IUGR. PI-MCA value of less than 11 was labeled as abnormal. PI-UA value of more than 1.451 was labeled as abnormal. Birth weight was taken as gold standard. Results: Sensitivity of PI-UA were 94.8% and 79.8%, respectively. Specificity of PI-UA and PI-MCA were 36.8% and 90.7%, respectively. Conclusion: Raised PI value of UA is highly sensitive of IUGR; lower PI value of MCA is highly specific of IUGR and grave sign of fetal demise. (author)

  7. ^3He Spin Pump

    Science.gov (United States)

    Yamaguchi, A.; Ishimoto, H.; Kojima, H.

    2009-03-01

    The superfluid component of ^3He A1 phase is spin-polarized. The process of forcing the superfluid component through a spin filtering structure, in a manner of mechano-magnetic effect, can be used to increase the spin polarization beyond the equilibrium under a given applied magnetic field. We have constructed a test cell in which a glass capillary array acts as the spin (and entropy) filter and an electrostatically actuated diaphragm forces the superfluid flow through it. Preliminary results show that a maximum relative increase of polarization by 50 % could be achieved. The maximum increase in polarization appears to be limited by the critical superfluid flow through the channels in the glass capillary array. The dependence of the observed effects on temperature, pressure and magnetic field will be presented.

  8. Nucleon Spin Structure: Experiment

    Science.gov (United States)

    Miller, Andy

    2003-04-01

    The experimental study of nucleon spin structure is at a transitional stage. Deeply inelastic scattering of leptons has revealed much about quark helicity distributions, and is approaching the limits of what is possible with present experimental facilities. The latest results from semi-inclusive measurements at HERMES will be presented. Precise new complementary data are expected soon from W production at RHIC-Spin. The gluon polarization will also be measured soon at COMPASS and RHIC. Meanwhile, single-spin asymmetries that promise to provide access to the unknown transversity distribution have been observed, and will be discussed. Based on these signals, the first measurements of transversity are underway. Finally, single spin asymmetries have also been recently observed in hard exclusive processes such as deeply virtual Compton scattering. These signals have the potential to provide a new window on both orbital angular momentum of partons, and on correlations between their longitudinal momentum and transverse position.

  9. Spin-Electromagnetic Hydrodynamics

    CERN Document Server

    Koide, T

    2013-01-01

    The hydrodynamic model including the spin degree of freedom and the electromagnetic field was discussed. In this derivation, we applied electromagnetism for macroscopic medium proposed by Minkowski. For the equation of motion of spin, we assumed that the hydrodynamic equation of the Pauli equation is reproduced when the many-body effect is neglected. The fluid and spin stress tensors induced by the many-body effect were obtained by employing the algebraic positivity of the entropy production in the framework of linear irreversible thermodynamics. In our model, the effect of the spin-magnetic interaction is absorbed into the magnetic polarization so as to satisfy the momentum and angular momentum conservations. We further compared our result with other existing models.

  10. Microscopic studies of nonlocal spin dynamics and spin transport (invited)

    International Nuclear Information System (INIS)

    Understanding the behavior of spins coupling across interfaces in the study of spin current generation and transport is a fundamental challenge that is important for spintronics applications. The transfer of spin angular momentum from a ferromagnet into an adjacent normal material as a consequence of the precession of the magnetization of the ferromagnet is a process known as spin pumping. We find that, in certain circumstances, the insertion of an intervening normal metal can enhance spin pumping between an excited ferromagnetic magnetization and a normal metal layer as a consequence of improved spin conductance matching. We have studied this using inverse spin Hall effect and enhanced damping measurements. Scanned probe magnetic resonance techniques are a complementary tool in this context offering high resolution magnetic resonance imaging, localized spin excitation, and direct measurement of spin lifetimes or damping. Localized magnetic resonance studies of size-dependent spin dynamics in the absence of lithographic confinement in both ferromagnets and paramagnets reveal the close relationship between spin transport and spin lifetime at microscopic length scales. Finally, detection of ferromagnetic resonance of a ferromagnetic film using the photoluminescence of nitrogen vacancy spins in neighboring nanodiamonds demonstrates long-range spin transport between insulating materials, indicating the complexity and generality of spin transport in diverse, spatially separated, material systems

  11. Microscopic studies of nonlocal spin dynamics and spin transport (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Adur, Rohan; Du, Chunhui; Cardellino, Jeremy; Scozzaro, Nicolas; Wolfe, Christopher S.; Wang, Hailong; Herman, Michael; Bhallamudi, Vidya P.; Pelekhov, Denis V.; Yang, Fengyuan; Hammel, P. Chris, E-mail: hammel@physics.osu.edu [Department of Physics, The Ohio State University, Columbus, Ohio 43210 (United States)

    2015-05-07

    Understanding the behavior of spins coupling across interfaces in the study of spin current generation and transport is a fundamental challenge that is important for spintronics applications. The transfer of spin angular momentum from a ferromagnet into an adjacent normal material as a consequence of the precession of the magnetization of the ferromagnet is a process known as spin pumping. We find that, in certain circumstances, the insertion of an intervening normal metal can enhance spin pumping between an excited ferromagnetic magnetization and a normal metal layer as a consequence of improved spin conductance matching. We have studied this using inverse spin Hall effect and enhanced damping measurements. Scanned probe magnetic resonance techniques are a complementary tool in this context offering high resolution magnetic resonance imaging, localized spin excitation, and direct measurement of spin lifetimes or damping. Localized magnetic resonance studies of size-dependent spin dynamics in the absence of lithographic confinement in both ferromagnets and paramagnets reveal the close relationship between spin transport and spin lifetime at microscopic length scales. Finally, detection of ferromagnetic resonance of a ferromagnetic film using the photoluminescence of nitrogen vacancy spins in neighboring nanodiamonds demonstrates long-range spin transport between insulating materials, indicating the complexity and generality of spin transport in diverse, spatially separated, material systems.

  12. Labelled molecules, modern research implements

    International Nuclear Information System (INIS)

    Details of the synthesis of carbon 14- and tritium-labelled molecules are examined. Although the methods used are those of classical organic chemistry the preparation of carbon 14-labelled molecules differs in some respects, most noticeably in the use of 14CO2 which requires very special handling techniques. For the tritium labelling of organic molecules the methods are somewhat different, very often involving exchange reactions. The following are described in turn: the so-called Wilzbach exchange method; exchange by catalysis in solution; catalytic hydrogenation with tritium; reductions with borotritides. Some applications of labelled molecules in organic chemistry, biochemistry and pharmacology are listed

  13. The radioactive labeling of monocytes

    International Nuclear Information System (INIS)

    With the aim of studying a possible relationship between circulating monocytes and Sternberg-Reed cells investigations were started on the specific labeling of monocytes. In this thesis the literature on the pertinent data has been reviewed and a series of experiments on the monocyte labeling procedure has been described. The principles of cell labeling with radioactive compounds were discussed. 1. Total separation of the particular cell population to be labeled and subsequent labeling with a non-specific radiopharmaceutical. 2. Specific cell labeling in a mixture of cell types based on a well defined affinity of the cell under study for the radiopharmaceutical used. Next the radionuclides that can be used for cell labeling purposes were discussed with special attention for 111In and its chelates. The principles of radiodosimetry were also discussed shortly. This section was focussed on the radiation dose the labeled cells receive because of the intracellular localized radioactivity. The radiation burden is high in comparison to amounts of radiation known to affect cell viability. A newly developed method for labeling monocytes specifically by phagocytosis of 111In-Fe-colloid without apparent loss of cells was described in detail. (Auth.)

  14. Bilateral Internal Thoracic Artery Configuration for Coronary Artery Bypass Surgery

    Science.gov (United States)

    Boodhwani, Munir; Hanet, Claude; de Kerchove, Laurent; Navarra, Emiliano; Astarci, Parla; Noirhomme, Philippe; El Khoury, Gebrine

    2016-01-01

    Background— Bilateral internal thoracic arteries (BITA) have demonstrated superior patency and improved survival in patients undergoing coronary artery bypass grafting. However, the optimal configuration for BITA utilization and its effect on long-term outcome remains uncertain. Methods and Results— We randomly assigned 304 patients undergoing coronary artery bypass grafting using BITA to either in situ or Y grafting configurations. The primary end point was 3-year angiographic patency. Secondary end points included major adverse cardiac and cerebrovascular events (ie, death from any cause, stroke, myocardial infarction, or repeat revascularization) at 7 years. More coronary targets were able to be revascularized using internal thoracic arteries in patients randomized to Y grafting versus in situ group (3.2±0.8 versus 2.4±0.5 arteries/patient; PURL: http://www.clinicaltrials.gov. Unique identifier: NCT01666366. PMID:27406988

  15. Genetics Home Reference: pulmonary arterial hypertension

    Science.gov (United States)

    ... Home Health Conditions pulmonary arterial hypertension pulmonary arterial hypertension Enable Javascript to view the expand/collapse boxes. ... All Open All Close All Description Pulmonary arterial hypertension is a progressive disorder characterized by abnormally high ...

  16. Are superparamagnetic spins classical?

    OpenAIRE

    Garanin, D. A.

    2008-01-01

    Effective giant spins of magnetic nanoparticles are considered classically in the conventional theory of superparamagnetism based on the Landau-Lifshitz-Langevin equation. However, microscopic calculations for a large spin with uniaxial anisotropy, coupled to the lattice via the simplest generic mechanism, show that the results of the conventional theory are not reproduced in the limit S ->\\infty. In particular, the prefactor Gamma_0 in the Arrhenius escape rate over the barrier Gamma =Gamma_...

  17. Spin and holographic metals

    OpenAIRE

    Alexandrov, Victor; Coleman, Piers

    2012-01-01

    In this paper we discuss two-dimensional holographic metals from a condensed matter physics perspective. We examine the spin structure of the Green's function of the holographic metal, demonstrating that the excitations of the holographic metal are "chiral", lacking the inversion symmetry of a conventional Fermi surface, with only one spin orientation for each point on the Fermi surface, aligned parallel to the momentum. While the presence of a Kramer's degeneracy across the Fermi surface per...

  18. Litter-Spinning Retarders

    Science.gov (United States)

    Wilson, John C.

    1995-01-01

    Aerodynamic plates stop litter from spinning during hoisting by helicopter. Features of proposed litter-spinning retarders include convenience of deployment and independence from ground restraint. Retarder plate(s) folded flat against bottom of litter during storage or while litter is loaded. Plate(s) held in storage position by latch that releases manually or automatically as litter is hoisted. Upon release, springs move plates into deployed position.

  19. Spin polarizability of hyperons

    Indian Academy of Sciences (India)

    K B Vijaya Kumar

    2014-11-01

    We review the recent progress of the theoretical understanding of spin polarizabilities of the hyperon in the framework of (3) heavy baryon chiral perturbation theory (HBChPT). We present the results of a systematic leading-order calculation of hyperon Compton scattering and extract the forward spin polarizability (0) of hyperons. The results obtained for $_0$ in the case of nucleons agree with the known results of (2) HBChPT when kaon loops are not considered.

  20. Nuclear spin effect in metallic spin valve

    OpenAIRE

    Danon, J.; Nazarov, Yu.V.

    2006-01-01

    We study electronic transport through a ferromagnet normal-metal ferromagnet system and we investigate the effect of hyperfine interaction between electrons and nuclei in the normal-metal part. A switching of the magnetization directions of the ferromagnets causes nuclear spins to precess. We show that the effect of this precession on the current through the system is large enough to be observed in experiment.