WorldWideScience

Sample records for arterial spin labeling

  1. Improving arterial spin labeling data by temporal filtering

    Science.gov (United States)

    Petr, Jan; Ferre, Jean-Christophe; Gauvrit, Jean-Yves; Barillot, Christian

    2010-03-01

    Arterial spin labeling (ASL) is an MRI method for imaging brain perfusion by magnetically labeling blood in brain feeding arteries. The perfusion is obtained from the difference between images with and without prior labeling. Image noise is one of the main problems of ASL as the difference is around 0.5-2% of the image magnitude. Usually, 20-40 pairs of images need to be acquired and averaged to reach a satisfactory quality. The images are acquired shortly after the labeling to allow the labeled blood to reach the imaged slice. A sequence of images with multiple delays is more suitable for quantification of the cerebral blood flow as it gives more information about the blood arrival and relaxation. Although the quantification methods are sensitive to noise, no filtering or only Gaussian filtering is used to denoise the data in the temporal domain prior to quantification. In this article, we propose an efficient way to use the redundancy of information in the time sequence of each pixel to suppress noise. For this purpose, the vectorial NL-means method is adapted to work in the temporal domain. The proposed method is tested on simulated and real 3T MRI data. We demonstrate a clear improvement of the image quality as well as a better performance compared to Gaussian and normal spatial NL-means filtering.

  2. Applications of arterial spin labeled MRI in the brain.

    Science.gov (United States)

    Detre, John A; Rao, Hengyi; Wang, Danny J J; Chen, Yu Fen; Wang, Ze

    2012-05-01

    Perfusion provides oxygen and nutrients to tissues and is closely tied to tissue function while disorders of perfusion are major sources of medical morbidity and mortality. It has been almost two decades since the use of arterial spin labeling (ASL) for noninvasive perfusion imaging was first reported. While initial ASL magnetic resonance imaging (MRI) studies focused primarily on technological development and validation, a number of robust ASL implementations have emerged, and ASL MRI is now also available commercially on several platforms. As a result, basic science and clinical applications of ASL MRI have begun to proliferate. Although ASL MRI can be carried out in any organ, most studies to date have focused on the brain. This review covers selected research and clinical applications of ASL MRI in the brain to illustrate its potential in both neuroscience research and clinical care.

  3. Bolus-tracking arterial spin labelling: theoretical and experimental results

    Science.gov (United States)

    Kelly, M. E.; Blau, C. W.; Kerskens, C. M.

    2009-03-01

    Arterial spin labelling (ASL) is a magnetic resonance imaging (MRI) technique that can be used to provide a quantitative assessment of cerebral perfusion. Despite the development of a number of theoretical models to facilitate quantitative ASL, some key challenges still remain. The purpose of this study is to develop a novel quantitative ASL method based on a macroscopic model that reduces the number of variables required to describe the physiological processes involved. To this end, a novel Fokker-Planck equation consisting of stochastically varying macroscopic variables was derived from a general Langevin equation. ASL data from the rat brain was acquired using a bolus-tracking ASL protocol where a bolus of labelled spins flowing from an inversion plane in the neck into an imaging plane in the brain can be observed. Bolus durations of 1.5 s, 2.0 s and 3.0 s were used and the solution to the Fokker-Planck equation for the boundary conditions of bolus-tracking ASL was fitted to the experimental data using a least-squares fit. The mean transit time (MTT) and capillary transit time (CTT) were calculated from the first and second moments of the resultant curve respectively and the arterial transit time (ATT) was calculated by subtracting the CTT from the MTT. The average MTT, CTT and ATT values were 1.75 ± 0.22 s, 1.43 ± 0.12 s and 0.32 ± 0.04 s respectively. In conclusion, a new ASL protocol has been developed by combining the theoretical model with ASL experiments. The technique has the unique ability to provide solutions for varying bolus volumes and the generality of the new model is demonstrated by the derivation of additional solutions for the continuous and pulsed ASL (CASL and PASL) techniques.

  4. Arterial spin-labeling MR imaging of cerebral hemorrhages

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Tomoyuki [Department of Radiology, National Center for Global Health and Medicine, Tokyo (Japan); Saga University, Department of Radiology, Faculty of Medicine and Graduate School of Medicine, Saga (Japan); Nishihara, Masashi; Egashira, Yoshiaki; Azama, Shinya; Hirai, Tetsuyoshi; Kitano, Isao; Irie, Hiroyuki [Saga University, Department of Radiology, Faculty of Medicine and Graduate School of Medicine, Saga (Japan); Yakushiji, Yusuke [Saga University, Department of Neurology, Faculty of Medicine and Graduate School of Medicine, Saga (Japan); Kawashima, Masatou [Saga University, Department of Neurosurgery, Faculty of Medicine and Graduate School of Medicine, Saga (Japan)

    2015-11-15

    The purpose of this study is to identify the characteristics of brain perfusion measured by arterial spin-labeling magnetic resonance imaging (ASL-MRI) in cerebral hemorrhages. Brain blood flow values (CBF-ASL values) for cerebral and cerebellar hemispheres and segmented cerebral regions were measured by ASL-MRI in 19 putaminal hemorrhage patients and 20 thalamic hemorrhage patients in acute or subacute stages. We assessed the lateralities of CBF-ASL values and the relationships between CBF-ASL values and other imaging findings and clinical manifestations. Both the 19 putaminal hemorrhage patients and the 20 thalamic hemorrhage patients had significantly low CBF-ASL values of the contralateral cerebellum in subacute stage, suggesting that ASL-MRI might delineate crossed cerebellar diaschisis (CCD). Ipsilateral low CBF-ASL values were observed in frontal lobes and thalami with a putaminal hemorrhage and lentiform nuclei, temporal lobes, and parietal lobes with a thalamic hemorrhage, suggesting that ASL-MRI showed the ipsilateral cerebral diaschisis (ICD). In the putaminal hemorrhage patients, the hematoma volume negatively affected both the bilateral cerebellar and cerebral hemispheric CBF-ASL values. In the thalamic hemorrhage patients, a concomitant intraventricular hemorrhage caused low cerebral hemispheric CBF-ASL values. The use of ASL-MRI is sensitive to the perfusion abnormalities and could thus be helpful to estimate functional abnormalities in cerebral hemorrhage patients. (orig.)

  5. Insight into the labeling mechanism of acceleration selective arterial spin labeling

    DEFF Research Database (Denmark)

    Schmid, Sophie; Petersen, Esben T; Van Osch, Matthias J P

    2016-01-01

    OBJECTIVES: Acceleration selective arterial spin labeling (AccASL) is a spatially non-selective labeling technique, used in traditional ASL methods, which labels spins based on their flow acceleration rather than spatial localization. The exact origin of the AccASL signal within the vasculature...... of the control and label conditions in both the acceleration and velocity selective module. The cut-off acceleration (0.59 m/s(2)) or velocity (2 cm/s) was kept constant in one module, while it was varied over a large range in the other module. With the right subtractions this resulted in AccASL, VS......-ASL, combined AccASL and VS-ASL signal, and signal from one module with crushing from the other. RESULTS: The label created with AccASL has an overlap of approximately 50% in the vascular region with VS-ASL, but also originates from smaller vessels closer to the capillaries. CONCLUSION: AccASL is able to label...

  6. Clinical utility of arterial spin-labeling as a confirmatory test for suspected brain death.

    Science.gov (United States)

    Kang, K M; Yun, T J; Yoon, B-W; Jeon, B S; Choi, S H; Kim, J-H; Kim, J E; Sohn, C-H; Han, M H

    2015-05-01

    Diagnosis of brain death is made on the basis of 3 essential findings: coma, absence of brain stem reflexes, and apnea. Although confirmatory tests are not mandatory in most situations, additional testing may be necessary to declare brain death in patients in whom results of specific components of clinical testing cannot be reliably evaluated. Recently, arterial spin-labeling has been incorporated as part of MR imaging to evaluate cerebral perfusion. Advantages of arterial spin-labeling include being completely noninvasive and providing information about absolute CBF. We retrospectively reviewed arterial spin-labeling findings according to the following modified criteria based on previously established confirmatory tests to determine brain death: 1) extremely decreased perfusion in the whole brain, 2) bright vessel signal intensity around the entry of the carotid artery to the skull, 3) patent external carotid circulation, and 4) "hollow skull sign" in a series of 5 patients. Arterial spin-labeling findings satisfied the criteria for brain death in all patients. Arterial spin-labeling imaging has the potential to be a completely noninvasive confirmatory test to provide additional information to assist in the diagnosis of brain death.

  7. Unilateral fetal-type circle of Willis anatomy causes right-left asymmetry in cerebral blood flow with pseudo-continuous arterial spin labeling: A limitation of arterial spin labeling-based cerebral blood flow measurements?

    Science.gov (United States)

    Barkeij Wolf, Jurriaan Jh; Foster-Dingley, Jessica C; Moonen, Justine Ef; van Osch, Matthias Jp; de Craen, Anton Jm; de Ruijter, Wouter; van der Mast, Roos C; van der Grond, Jeroen

    2016-09-01

    The accuracy of cerebral blood flow measurements using pseudo-continuous arterial spin labeling can be affected by vascular factors other than cerebral blood flow, such as flow velocity and arterial transit time. We aimed to elucidate the effects of common variations in vascular anatomy of the circle of Willis on pseudo-continuous arterial spin labeling signal. In addition, we investigated whether possible differences in pseudo-continuous arterial spin labeling signal could be mediated by differences in flow velocities. Two hundred and three elderly participants underwent magnetic resonance angiography of the circle of Willis and pseudo-continuous arterial spin labeling scans. Mean pseudo-continuous arterial spin labeling-cerebral blood flow signal was calculated for the gray matter of the main cerebral flow territories. Mean cerebellar gray matter pseudo-continuous arterial spin labeling-cerebral blood flow was significantly lower in subjects having a posterior fetal circle of Willis variant with an absent P1 segment. The posterior fetal circle of Willis variants also showed a significantly higher pseudo-continuous arterial spin labeling-cerebral blood flow signal in the ipsilateral flow territory of the posterior cerebral artery. Flow velocity in the basilar artery was significantly lower in these posterior fetal circle of Willis variants. This study indicates that pseudo-continuous arterial spin labeling measurements underestimate cerebral blood flow in the posterior flow territories and cerebellum of subjects with a highly prevalent variation in circle of Willis morphology. Additionally, our data suggest that this effect is mediated by concomitant differences in flow velocity between the supplying arteries.

  8. Arterial spin labelling in imaging of renal diseases and renal allograft pathology; MRT-Perfusionsmessung mit Arterial Spin Labelling. Anwendung fuer die Niere und Transplantatniere

    Energy Technology Data Exchange (ETDEWEB)

    Hueper, Katja; Gutberlet, Marcel [Medizinische Hochschule Hannover (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Kuehn, Bernd [Siemens AG/Siemens Healthcare GmbH, Erlangen (Germany)

    2016-06-15

    Arterial Spin Labelling (ASL) is a technique for non-invasive and contrast-free assessment of perfusion with MRI. Renal ASL allows examination of renal pathophysiology, evaluation of the course of renal disease and therapy effects by longitudinal measurements as well as characterization of renal tumors. In this article, techniques of ASL will be explained and challenges of renal ASL will be emphasized. In addition, examples for clinical application of ASL for diagnosis of renal disease and renal allograft pathology will be given.

  9. Arterial and portal venous liver perfusion using selective spin labelling MRI

    Energy Technology Data Exchange (ETDEWEB)

    Schalkx, Hanke J.; Petersen, Esben T.; Veldhuis, Wouter B.; Leeuwen, Maarten S. van; Bosch, Maurice A.A.J. van den [University Medical Center Utrecht, Department of Radiology, HP E.01.132, Postbus 85500, Utrecht (Netherlands); Peters, Nicky H.G.M. [Atrium Medical Center Parkstad, Department of Radiology, Heerlen (Netherlands); Pluim, Josien P.W.; Stralen, Marijn van [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands)

    2015-06-01

    To investigate the feasibility of selective arterial and portal venous liver perfusion imaging with spin labelling (SL) MRI, allowing separate labelling of each blood supply. The portal venous perfusion was assessed with a pulsed EPISTAR technique and the arterial perfusion with a pseudo-continuous sequence. To explore precision and reproducibility, portal venous and arterial perfusion were separately quantified in 12 healthy volunteers pre- and postprandially (before and after meal intake). In a subgroup of 6 volunteers, the accuracy of the absolute portal perfusion and its relative postprandial change were compared with MRI flow measurements of the portal vein. The portal venous perfusion significantly increased from 63 ± 22 ml/100g/min preprandially to 132 ± 42 ml/100g/min postprandially. The arterial perfusion was lower with 35 ± 22 preprandially and 22 ± 30 ml/100g/min postprandially. The pre- and postprandial portal perfusion using SL correlated well with flow-based perfusion (r{sup 2} = 0.71). Moreover, postprandial perfusion change correlated well between SL- and flow-based quantification (r{sup 2} = 0.77). The SL results are in range with literature values. Selective spin labelling MRI of the portal venous and arterial blood supply successfully quantified liver perfusion. This non-invasive technique provides specific arterial and portal venous perfusion imaging and could benefit clinical settings where contrast agents are contraindicated. (orig.)

  10. A method for reducing the effects of motion contamination in arterial spin labeling magnetic resonance imaging.

    Science.gov (United States)

    Tanenbaum, Aaron B; Snyder, Abraham Z; Brier, Matthew R; Ances, Beau M

    2015-10-01

    Arterial spin labeling (ASL) is a noninvasive method to measure cerebral blood flow (CBF). Arterial spin labeling is susceptible to artifact generated by head motion; this artifact is propagated through the subtraction procedure required to calculate CBF. We introduce a novel strategy for mitigating this artifact based on weighting tag/control volumes according to a noise estimate. We evaluated this strategy (DVARS weighting) in application to both pulsed ASL (PASL) and pseudo-continuous ASL (pCASL) in a cohort of normal adults (N=57). Application of DVARS weighting significantly improved test-retest repeatability as assessed by the intra-class correlation coefficient. Before the application of DVARS weighting, mean gray matter intra-class correlation (ICC) between subsequent ASL runs was 0.48 and 0.51 in PASL and pCASL, respectively. With weighting, ICC was significantly improved to 0.63 and 0.58.

  11. Pseudo-asymmetry of cerebral blood flow in arterial spin labeling caused by unilateral fetal-type circle of Willis: Technical limitation or a way to better understanding physiological variations of cerebral perfusion and improving arterial spin labeling acquisition?

    Science.gov (United States)

    Law-Ye, B; Geerts, B; Galanaud, D; Dormont, D; Pyatigorskaya, N

    2016-09-01

    In the recently published article, "Unilateral fetal-type circle of Willis anatomy causes right-left asymmetry in cerebral blood flow with pseudo-continuous arterial spin labeling: A limitation of arterial spin labeling-based cerebral blood flow measurements?", it was shown by the method of arterial spin labeling (ASL) that unilateral fetal-type circle of Willis could induce variation of blood flow in cerebellar and posterior cerebral artery territory. We believe that the reported observation, rather than being a limitation, gives several interesting cues for understanding the ASL sequence. In this commentary, we formulate some suggestions regarding the use of ASL in clinical practice, discuss the potential causes of the above-mentioned pseudo-asymmetry and consider future improvements of the ASL technique.

  12. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier;

    2010-01-01

    Arterial Spin Labeling (ASL) is a method to measure perfusion using magnetically labeled blood water as an endogenous tracer. Being fully non-invasive, this technique is attractive for longitudinal studies of cerebral blood flow in healthy and diseased individuals, or as a surrogate marker of met...

  13. Measurement of vascular water transport in human subjects using time-resolved pulsed arterial spin labelling.

    Science.gov (United States)

    Bibic, Adnan; Knutsson, Linda; Schmidt, Anders; Henningsson, Erik; Månsson, Sven; Abul-Kasim, Kasim; Åkeson, Jonas; Gunther, Matthias; Ståhlberg, Freddy; Wirestam, Ronnie

    2015-08-01

    Most approaches to arterial spin labelling (ASL) data analysis aim to provide a quantitative measure of the cerebral blood flow (CBF). This study, however, focuses on the measurement of the transfer time of blood water through the capillaries to the parenchyma (referred to as the capillary transfer time, CTT) as an alternative parameter to characterise the haemodynamics of the system. The method employed is based on a non-compartmental model, and no measurements need to be added to a common time-resolved ASL experiment. Brownian motion of labelled spins in a potential was described by a one-dimensional general Langevin equation as the starting point, and as a Fokker-Planck differential equation for the averaged distribution of labelled spins at the end point, which takes into account the effects of flow and dispersion of labelled water by the pseudorandom nature of the microvasculature and the transcapillary permeability. Multi-inversion time (multi-TI) ASL data were acquired in 14 healthy subjects on two occasions in a test-retest design, using a pulsed ASL sequence and three-dimensional gradient and spin echo (3D-GRASE) readout. Based on an error analysis to predict the size of a region of interest (ROI) required to obtain reasonably precise parameter estimates, data were analysed in two relatively large ROIs, i.e. the occipital lobe (OC) and the insular cortex (IC). The average values of CTT in OC were 260 ± 60 ms in the first experiment and 270 ± 60 ms in the second experiment. The corresponding IC values were 460 ± 130 ms and 420 ± 139 ms, respectively. Information related to the water transfer time may be important for diagnostics and follow-up of cerebral conditions or diseases characterised by a disrupted blood-brain barrier or disturbed capillary blood flow.

  14. Reduction in cerebral perfusion after heroin administration: a resting state arterial spin labeling study.

    Directory of Open Access Journals (Sweden)

    Niklaus Denier

    Full Text Available Heroin dependence is a chronic relapsing brain disorder, characterized by the compulsion to seek and use heroin. Heroin itself has a strong potential to produce subjective experiences characterized by intense euphoria, relaxation and release from craving. The neurofunctional foundations of these perceived effects are not well known. In this study, we have used pharmacological magnetic resonance imaging (phMRI in 15 heroin-dependent patients from a stable heroin-assisted treatment program to observe the steady state effects of heroin (60 min after administration. Patients were scanned in a cross-over and placebo controlled design. They received an injection of their regular dose of heroin or saline (placebo before or after the scan. As phMRI method, we used a pulsed arterial spin labeling (ASL sequence based on a flow-sensitive alternating inversion recovery (FAIR spin labeling scheme combined with a single-shot 3D GRASE (gradient-spin echo readout on a 3 Tesla scanner. Analysis was performed with Statistical Parametric Mapping (SPM 8, using a general linear model for whole brain comparison between the heroin and placebo conditions. We found that compared to placebo, heroin was associated with reduced perfusion in the left anterior cingulate cortex (ACC, the left medial prefrontal cortex (mPFC and in the insula (both hemispheres. Analysis of extracted perfusion values indicate strong effect sizes and no gender related differences. Reduced perfusion in these brain areas may indicate self- and emotional regulation effects of heroin in maintenance treatment.

  15. Noninvasive measurements of regional cerebral perfusion in preterm and term neonates by magnetic resonance arterial spin labeling

    DEFF Research Database (Denmark)

    Miranda Gimenez-Ricco, Maria Jo; Olofsson, K; Sidaros, Karam

    2006-01-01

    Magnetic resonance arterial spin labeling (ASL) at 3 Tesla has been investigated as a quantitative technique for measuring regional cerebral perfusion (RCP) in newborn infants. RCP values were measured in 49 healthy neonates: 32 preterm infants born before 34 wk of gestation and 17 term-born neon......Magnetic resonance arterial spin labeling (ASL) at 3 Tesla has been investigated as a quantitative technique for measuring regional cerebral perfusion (RCP) in newborn infants. RCP values were measured in 49 healthy neonates: 32 preterm infants born before 34 wk of gestation and 17 term...

  16. Two analytical solutions for a model of pulsed arterial spin labeling with randomized blood arrival times

    Science.gov (United States)

    Hrabe, J.; Lewis, D. P.

    2004-03-01

    A fairly general theoretical model for pulsed arterial spin labeling perfusion methods has been available for some time but analytical solutions were derived for only a small number of arterial blood input functions. These mostly assumed a sudden and simultaneous arrival of the tagged blood into the imaged region. More general cases had to be handled numerically. We present analytical solutions for two more realistic arterial input functions. They both allow the arrival times of the molecules of tagged arterial blood to be statistically distributed. We consider cases of (1) a uniform distribution on a finite time interval and (2) a normal distribution characterized by its mean and standard deviation. These models are physiologically meaningful because the statistical nature of the arrival times reflects the distribution of velocities and path lengths that the blood water molecules undertake from the tagging region to the imaged region. The model parameters can be estimated from the measured dependency of the perfusion signal on the tag inversion time.

  17. Arterial spin labeling in patients with chic cerebral artery steno-occlusive disease - Correlation with {sup 15}O-PET

    Energy Technology Data Exchange (ETDEWEB)

    Kamano, Hironori; Yoshiura, Takashi; Hiwatashi, Akio; Abe, Koichiro; Yamashita, Koji; Honda, Hiroshi [Dept. of Clinical Radiology, Graduate School of Medical Sciences, Kyushu Univ., Fukuoka (Japan)], e-mail: tsu@radiol.med.kyushu-u.ac.jp; Togao, Osamu [Dept. of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu Univ., Fukuoka (Japan)

    2013-02-15

    Background: Heterogeneity of arterial transit time due to cerebral artery steno-occlusive lesions hampers accurate regional cerebral blood flow measurement by arterial spin labeling (ASL). Purpose: To assess the feasibility of regional cerebral blood flow measurement by ASL with multiple-delay time sampling in patients with steno-occlusive diseases by comparing with positron emission tomography (PET), and to determine whether regional arterial transit time measured by this ASL technique is correlated with regional mean transit time, a PET index of perfusion pressure. Material and Methods: Sixteen patients with steno-occlusive diseases received both ASL and {sup 15}O-PET. The mean regional cerebral blood flow measured by ASL and PET, regional arterial transit time by ASL, and regional mean transit time by PET were obtained by a region-of-interest analysis. Correlation between regional cerebral blood flow by ASL and that by PET, and correlation between regional arterial transit time by ASL and regional mean transit time by PET were tested using Pearson's correlation coefficient for both absolute and relative values. A multivariate regression analysis was performed to test whether regional arterial transit time by ASL was a significant contributor in modeling regional mean transit time by PET after controlling the effect of regional cerebral blood flow by ASL. Results: A significant positive correlation was found between regional cerebral blood flow by ASL and that by PET for both absolute (r = 0.520, P < 0.0001) and relative (r = 0.691, P < 0.0001) values. A significant positive correlation was found between regional arterial transit time by ASL and regional mean transit time by PET both for absolute (r = 0.369, P = 0.0002) and relative (r = 0.443, P < 0.0001) values. The regression analysis revealed that regional arterial transit time by ASL was a significant contributor in modeling regional mean transit time by PET after controlling regional cerebral blood flow by

  18. Rapid 3D dynamic arterial spin labeling with a sparse model-based image reconstruction.

    Science.gov (United States)

    Zhao, Li; Fielden, Samuel W; Feng, Xue; Wintermark, Max; Mugler, John P; Meyer, Craig H

    2015-11-01

    Dynamic arterial spin labeling (ASL) MRI measures the perfusion bolus at multiple observation times and yields accurate estimates of cerebral blood flow in the presence of variations in arterial transit time. ASL has intrinsically low signal-to-noise ratio (SNR) and is sensitive to motion, so that extensive signal averaging is typically required, leading to long scan times for dynamic ASL. The goal of this study was to develop an accelerated dynamic ASL method with improved SNR and robustness to motion using a model-based image reconstruction that exploits the inherent sparsity of dynamic ASL data. The first component of this method is a single-shot 3D turbo spin echo spiral pulse sequence accelerated using a combination of parallel imaging and compressed sensing. This pulse sequence was then incorporated into a dynamic pseudo continuous ASL acquisition acquired at multiple observation times, and the resulting images were jointly reconstructed enforcing a model of potential perfusion time courses. Performance of the technique was verified using a numerical phantom and it was validated on normal volunteers on a 3-Tesla scanner. In simulation, a spatial sparsity constraint improved SNR and reduced estimation errors. Combined with a model-based sparsity constraint, the proposed method further improved SNR, reduced estimation error and suppressed motion artifacts. Experimentally, the proposed method resulted in significant improvements, with scan times as short as 20s per time point. These results suggest that the model-based image reconstruction enables rapid dynamic ASL with improved accuracy and robustness.

  19. 3D Pseudocontinuous arterial spin labeling in routine clinical practice: A review of clinically significant artifacts.

    Science.gov (United States)

    Amukotuwa, Shalini A; Yu, Caroline; Zaharchuk, Gregory

    2016-01-01

    Arterial spin labeling (ASL) is a completely noninvasive magnetic resonance imaging (MRI) perfusion method for quantitatively measuring cerebral blood flow utilizing magnetically labeled arterial water. Advances in the technique have enabled the major MRI vendors to make the sequence available to the clinical neuroimaging community. Consequently, ASL is being increasingly incorporated into the routine neuroimaging protocol. Although a variety of ASL techniques are available, the ISMRM Perfusion Study Group and the European ASL in Dementia Consortium have released consensus guidelines recommending standardized implementation of 3D pseudocontinuous ASL with background suppression. The purpose of this review, aimed at the large number of neuroimaging clinicians who have either no or limited experience with this 3D pseudocontinuous ASL, is to discuss the common and clinically significant artifacts that may be encountered with this technique. While some of these artifacts hinder accurate interpretation of studies, either by degrading the images or mimicking pathology, there are other artifacts that are of clinical utility, because they increase the conspicuity of pathology. Cognizance of these artifacts will help the physician interpreting ASL to avoid potential diagnostic pitfalls, and increase their level of comfort with the technique.

  20. Sickle Cell Anemia: Reference Values of Cerebral Blood Flow Determined by Continuous Arterial Spin Labeling MRI

    Science.gov (United States)

    Arkuszewski, M.; Krejza, J.; Chen, R.; Melhem, E.R.

    2013-01-01

    Sickle cell anemia (SCA) is a chronic illness associated with progressive deterioration in patients' quality of life. The major complications of SCA are cerebrovascular accidents (CVA) such as asymptomatic cerebral infarct or overt stroke. The risk of CVA may be related to chronic disturbances in cerebral blood flow (CBF), but the thresholds of “normal” steady-state CBF are not well established. The reference tolerance limits of CBF can be useful to estimate the risk of CVA in asymptomatic children with SCA, who are negative for hyperemia or evidence of arterial narrowing. Continuous arterial spin labeling (CASL) MR perfusion allows for non-invasive quantification of global and regional CBF. To establish such reference tolerance limits we performed CASL MR examinations on a 3-Tesla MR scanner in a carefully selected cohort of 42 children with SCA (mean age, 8.1±3.3 years; range limits, 2.3–14.4 years; 24 females), who were not on chronic transfusion therapy, had no history of overt stroke or transient ischemic attack, were free of signs and symptoms of focal vascular territory ischemic brain injury, did not have intracranial arterial narrowing on MR angiography and were at low risk for stroke as determined by transcranial Doppler ultrasonography. PMID:23859242

  1. Sickle cell anemia: reference values of cerebral blood flow determined by continuous arterial spin labeling MRI.

    Science.gov (United States)

    Arkuszewski, M; Krejza, J; Chen, R; Melhem, E R

    2013-04-01

    Sickle cell anemia (SCA) is a chronic illness associated with progressive deterioration in patients' quality of life. The major complications of SCA are cerebrovascular accidents (CVA) such as asymptomatic cerebral infarct or overt stroke. The risk of CVA may be related to chronic disturbances in cerebral blood flow (CBF), but the thresholds of "normal" steady-state CBF are not well established. The reference tolerance limits of CBF can be useful to estimate the risk of CVA in asymptomatic children with SCA, who are negative for hyperemia or evidence of arterial narrowing. Continuous arterial spin labeling (CASL) MR perfusion allows for non-invasive quantification of global and regional CBF. To establish such reference tolerance limits we performed CASL MR examinations on a 3-Tesla MR scanner in a carefully selected cohort of 42 children with SCA (mean age, 8.1±3.3 years; range limits, 2.3-14.4 years; 24 females), who were not on chronic transfusion therapy, had no history of overt stroke or transient ischemic attack, were free of signs and symptoms of focal vascular territory ischemic brain injury, did not have intracranial arterial narrowing on MR angiography and were at low risk for stroke as determined by transcranial Doppler ultrasonography.

  2. Improving perfusion quantification in arterial spin labeling for delayed arrival times by using optimized acquisition schemes

    Energy Technology Data Exchange (ETDEWEB)

    Kramme, Johanna [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); Univ. Bremen (Germany). Faculty of Physics and Electronics; Gregori, Johannes [mediri GmbH, Heidelberg (Germany); Diehl, Volker [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); ZEMODI (Zentrum fuer morderne Diagnostik), Bremen (Germany); Madai, Vince I.; Sobesky, Jan [Charite-Universitaetsmedizin Berlin (Germany). Center for Stroke Research Berlin (CSB); Charite-Universitaetsmedizin Berlin (Germany). Dept. of Neurology; Samson-Himmelstjerna, Frederico C. von [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); Charite-Universitaetsmedizin Berlin (Germany). Center for Stroke Research Berlin (CSB); Charite-Universitaetsmedizin Berlin (Germany). Dept. of Neurology; Lentschig, Markus [ZEMODI (Zentrum fuer morderne Diagnostik), Bremen (Germany); Guenther, Matthias [Fraunhofer MEVIS-Institute for Medical Image Computing, Bremen (Germany); Univ. Bremen (Germany). Faculty of Physics and Electronics; mediri GmbH, Heidelberg (Germany)

    2015-07-01

    The improvement in Arterial Spin Labeling (ASL) perfusion quantification, especially for delayed bolus arrival times (BAT), with an acquisition redistribution scheme mitigating the T1 decay of the label in multi-TI ASL measurements is investigated. A multi inflow time (TI) 3D-GRASE sequence is presented which adapts the distribution of acquisitions accordingly, by keeping the scan time constant. The MR sequence increases the number of averages at long TIs and decreases their number at short TIs and thus compensating the T1 decay of the label. The improvement of perfusion quantification is evaluated in simulations as well as in-vivo in healthy volunteers and patients with prolonged BATs due to age or steno-occlusive disease. The improvement in perfusion quantification depends on BAT. At healthy BATs the differences are small, but become larger for longer BATs typically found in certain diseases. The relative error of perfusion is improved up to 30% at BATs > 1500 ms in comparison to the standard acquisition scheme. This adapted acquisition scheme improves the perfusion measurement in comparison to standard multi-TI ASL implementations. It provides relevant benefit in clinical conditions that cause prolonged BATs and is therefore of high clinical relevance for neuroimaging of steno-occlusive diseases.

  3. Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Lanzman, Rotem S.; Wittsack, Hans-Joerg; Bilk, Philip; Kroepil, Patric; Blondin, Dirk [University Hospital Duesseldorf, Department of Radiology, Duesseldorf (Germany); Martirosian, Petros; Schick, Fritz [University Hospital Tuebingen, Section for Experimental Radiology, Department of Diagnostic Radiology, Tuebingen (Germany); Zgoura, Panagiota; Voiculescu, Adina [University Hospital Duesseldorf, Department of Nephrology, Duesseldorf (Germany)

    2010-06-15

    To quantify renal allograft perfusion in recipients with stable allograft function and acute decrease in allograft function using nonenhanced flow-sensitive alternating inversion recovery (FAIR)-TrueFISP arterial spin labeling (ASL) MR imaging. Following approval of the local ethics committee, 20 renal allograft recipients were included in this study. ASL perfusion measurement and an anatomical T2-weighted single-shot fast spin-echo (HASTE) sequence were performed on a 1.5-T scanner (Magnetom Avanto, Siemens, Erlangen, Germany). T2-weighted MR urography was performed in patients with suspected ureteral obstruction. Patients were assigned to three groups: group a, 6 patients with stable allograft function over the previous 4 months; group b, 7 patients with good allograft function who underwent transplantation during the previous 3 weeks; group c, 7 allograft recipients with an acute deterioration of renal function. Mean cortical perfusion values were 304.8 {+-} 34.4, 296.5 {+-} 44.1, and 181.9 {+-} 53.4 mg/100 ml/min for groups a, b and c, respectively. Reduction in cortical perfusion in group c was statistically significant. Our results indicate that ASL is a promising technique for nonenhanced quantification of cortical perfusion of renal allografts. Further studies are required to determine the clinical value of ASL for monitoring renal allograft recipients. (orig.)

  4. Arterial spin-labeled MRI study of migraine attacks treated with rizatriptan.

    Science.gov (United States)

    Kato, Yuji; Araki, Nobuo; Matsuda, Hiroshi; Ito, Yasuo; Suzuki, Chihiro

    2010-06-01

    Spin-tag perfusion imaging is an MRI method that quantitatively measures cerebral blood flow. Compared with conventional perfusion techniques, advantages of this arterial spin-labeling (ASL) include repeatability and the avoidance of intravenous contrast administration. In the present study, we performed an analysis of 3T high-field MRI examinations utilizing ASL perfusion during migraine attacks. A 32-year-old male patient was studied in three situations: during migraine attack within 1 h post-onset, 30 min after oral administration of rizatriptan 10 mg, and attack-free period. Normalized ASL images acquired during migraine attack showed significant relative hypoperfusion in the bilateral median thalamic areas including hypothalamus and significant relative hyperperfusion in the frontal cortex compared to images acquired during the migraine-free state. When normalized ASL images acquired 30 min after treatment were compared with those acquired during the attack, relative improvement of perfusion in the bilateral median thalamic areas including hypothalamus was observed. Hypothalamus and its surrounding areas may participate in the pathogenesis in migraine attack.

  5. Early development of arterial spin labeling to measure regional brain blood flow by MRI.

    Science.gov (United States)

    Koretsky, Alan P

    2012-08-15

    Two major avenues of work converged in the late 1980's and early 1990's to give rise to brain perfusion MRI. The development of anatomical brain MRI quickly had as a major goal the generation of angiograms using tricks to label flowing blood in macroscopic vessels. These ideas were aimed at getting information about microcirculatory flow as well. Over the same time course the development of in vivo magnetic resonance spectroscopy had as its primary goal the assessment of tissue function and in particular, tissue energetics. For this the measurement of the delivery of water to tissue was critical for assessing tissue oxygenation and viability. The measurement of the washin/washout of "freely" diffusible tracers by spectroscopic based techniques pointed the way for quantitative approaches to measure regional blood flow by MRI. These two avenues came together in the development of arterial spin labeling (ASL) MRI techniques to measure regional cerebral blood flow. The early use of ASL to measure brain activation to help verify BOLD fMRI led to a rapid development of ASL based perfusion MRI. Today development and applications of regional brain blood flow measurements with ASL continues to be a major area of activity.

  6. A neuroradiologist's guide to arterial spin labeling MRI in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Grade, M. [Queen Square, UCL Institute of Neurology, London (United Kingdom); Stanford School of Medicine, Stanford, CA (United States); Hernandez Tamames, J.A. [Rey Juan Carlos University, Medical Image Analysis and Biometry Laboratory, Madrid (Spain); Erasmus MC - University Medical Centre Rotterdam, Department of Radiology, PO Box 2040, Rotterdam (Netherlands); Pizzini, F.B. [Queen Square, UCL Institute of Neurology, London (United Kingdom); Verona University Hospital, Neuroradiology, Department of Diagnostics and Pathology, Verona (Italy); Achten, E. [Ghent University Hospital, Neuroradiology, Department of Radiology, Ghent (Belgium); Golay, X. [Queen Square, UCL Institute of Neurology, London (United Kingdom); Smits, M. [Erasmus MC - University Medical Centre Rotterdam, Department of Radiology, PO Box 2040, Rotterdam (Netherlands)

    2015-12-15

    Arterial spin labeling (ASL) is a non-invasive MRI technique to measure cerebral blood flow (CBF). This review provides a practical guide and overview of the clinical applications of ASL of the brain, as well its potential pitfalls. The technical and physiological background is also addressed. At present, main areas of interest are cerebrovascular disease, dementia and neuro-oncology. In cerebrovascular disease, ASL is of particular interest owing to its quantitative nature and its capability to determine cerebral arterial territories. In acute stroke, the source of the collateral blood supply in the penumbra may be visualised. In chronic cerebrovascular disease, the extent and severity of compromised cerebral perfusion can be visualised, which may be used to guide therapeutic or preventative intervention. ASL has potential for the detection and follow-up of arteriovenous malformations. In the workup of dementia patients, ASL is proposed as a diagnostic alternative to PET. It can easily be added to the routinely performed structural MRI examination. In patients with established Alzheimer's disease and frontotemporal dementia, hypoperfusion patterns are seen that are similar to hypometabolism patterns seen with PET. Studies on ASL in brain tumour imaging indicate a high correlation between areas of increased CBF as measured with ASL and increased cerebral blood volume as measured with dynamic susceptibility contrast-enhanced perfusion imaging. Major advantages of ASL for brain tumour imaging are the fact that CBF measurements are not influenced by breakdown of the blood-brain barrier, as well as its quantitative nature, facilitating multicentre and longitudinal studies. (orig.)

  7. Mapping Long-Term Functional Changes in Cerebral Blood Flow by Arterial Spin Labeling

    Science.gov (United States)

    Ssali, Tracy; Anazodo, Udunna C.; Bureau, Yves; MacIntosh, Bradley J.; Günther, Matthias; St. Lawrence, Keith

    2016-01-01

    Although arterial spin labeling (ASL) is appealing for mapping long-term changes in functional activity, inter-sessional variations in basal blood flow, arterial transit times (ATTs), and alignment errors, can result in significant false activation when comparing images from separate sessions. By taking steps to reduce these sources of noise, this study assessed the ability of ASL to detect functional CBF changes between sessions. ASL data were collected in three sessions to image ATT, resting CBF and CBF changes associated with motor activation (7 participants). Activation maps were generated using rest and task images acquired in the same session and from sessions separated by up to a month. Good agreement was found when comparing between-session activation maps to within-session activation maps with only a 16% decrease in precision (within-session: 90 ± 7%) and a 13% decrease in the Dice similarity (within-session: 0.75 ± 0.07) coefficient after a month. In addition, voxel-wise reproducibility (within-session: 4.7 ± 4.5%) and reliability (within-session: 0.89 ± 0.20) of resting grey-matter CBF decreased by less than 18% for the between-session analysis relative to within-session values. ATT variability between sessions (5.0 ± 2.7%) was roughly half the between-subject variability, indicating that its effects on longitudinal CBF were minimal. These results demonstrate that conducting voxel-wise analysis on CBF images acquired on different days is feasible with only modest loss in precision, highlighting the potential of ASL for longitudinal studies. PMID:27706218

  8. Combined Diffusion Tensor Imaging and Arterial Spin Labeling as Markers of Early Parkinson’s disease

    Science.gov (United States)

    Wei, Xiaobo; Yan, Ronghua; Chen, Zhaoyu; Weng, Ruihui; Liu, Xu; Gao, Huimin; Xu, Xiaofeng; Kang, Zhuang; Liu, Zhexing; Guo, Yan; Liu, Zhenhua; Larsen, Jan Petter; Wang, Jin; Tang, Beisha; Hallett, Mark; Wang, Qing

    2016-01-01

    This study aimed to identify a PD-specific MRI pattern using combined diffusion tensor imaging (DTI) and arterial spin labeling (ASL) to discriminate patients with early PD from healthy subjects and evaluate disease status. Twenty-one early and 22 mid-late PD patients, and 22 healthy, age/gender-matched controls underwent 3-T MRI with apparent diffusion coefficient (ADC), fractional anisotropy (FA), fiber number (FN) and cerebral blood flow (CBF) measurements. We found that compared with healthy subjects, there was a profound reduction in FN passing through the SN in PD. FA in the SN and CBF in the caudate nucleus were inversely correlated with motor dysfunction. A negative correlation was observed between FA in the hippocampus (Hip) and the NMSS-Mood score, whereas CBF in the Hip and the prefrontal cortex(PFC) correlated with declined cognition. Stratified five-fold cross-validation identified FA in the SN(FA-SNAv), CBF in the PFC(CBF-PFCAv) and FA in the parietal white matter(FA-PWMAv), and the combination of these measurements offered relatively high accuracy (AUC 0.975, 90% sensitivity and 100% specificity) in distinguishing those with early PD from healthy subjects. We demonstrate that the decreased FNs through SN in combination with changes in FA-SNAv, CBF-PFCAv and FA-PWMAv values might serve as potential markers of early-stage PD. PMID:27646647

  9. Combined Diffusion Tensor Imaging and Arterial Spin Labeling as Markers of Early Parkinson's disease.

    Science.gov (United States)

    Wei, Xiaobo; Yan, Ronghua; Chen, Zhaoyu; Weng, Ruihui; Liu, Xu; Gao, Huimin; Xu, Xiaofeng; Kang, Zhuang; Liu, Zhexing; Guo, Yan; Liu, Zhenhua; Larsen, Jan Petter; Wang, Jin; Tang, Beisha; Hallett, Mark; Wang, Qing

    2016-09-20

    This study aimed to identify a PD-specific MRI pattern using combined diffusion tensor imaging (DTI) and arterial spin labeling (ASL) to discriminate patients with early PD from healthy subjects and evaluate disease status. Twenty-one early and 22 mid-late PD patients, and 22 healthy, age/gender-matched controls underwent 3-T MRI with apparent diffusion coefficient (ADC), fractional anisotropy (FA), fiber number (FN) and cerebral blood flow (CBF) measurements. We found that compared with healthy subjects, there was a profound reduction in FN passing through the SN in PD. FA in the SN and CBF in the caudate nucleus were inversely correlated with motor dysfunction. A negative correlation was observed between FA in the hippocampus (Hip) and the NMSS-Mood score, whereas CBF in the Hip and the prefrontal cortex(PFC) correlated with declined cognition. Stratified five-fold cross-validation identified FA in the SN(FA-SNAv), CBF in the PFC(CBF-PFCAv) and FA in the parietal white matter(FA-PWMAv), and the combination of these measurements offered relatively high accuracy (AUC 0.975, 90% sensitivity and 100% specificity) in distinguishing those with early PD from healthy subjects. We demonstrate that the decreased FNs through SN in combination with changes in FA-SNAv, CBF-PFCAv and FA-PWMAv values might serve as potential markers of early-stage PD.

  10. Quantifying Cerebellum Grey Matter and White Matter Perfusion Using Pulsed Arterial Spin Labeling

    Directory of Open Access Journals (Sweden)

    Xiufeng Li

    2014-01-01

    Full Text Available To facilitate quantification of cerebellum cerebral blood flow (CBF, studies were performed to systematically optimize arterial spin labeling (ASL parameters for measuring cerebellum perfusion, segment cerebellum to obtain separate CBF values for grey matter (GM and white matter (WM, and compare FAIR ASST to PICORE. Cerebellum GM and WM CBF were measured with optimized ASL parameters using FAIR ASST and PICORE in five subjects. Influence of volume averaging in voxels on cerebellar grey and white matter boundaries was minimized by high-probability threshold masks. Cerebellar CBF values determined by FAIR ASST were 43.8 ± 5.1 mL/100 g/min for GM and 27.6 ± 4.5 mL/100 g/min for WM. Quantitative perfusion studies indicated that CBF in cerebellum GM is 1.6 times greater than that in cerebellum WM. Compared to PICORE, FAIR ASST produced similar CBF estimations but less subtraction error and lower temporal, spatial, and intersubject variability. These are important advantages for detecting group and/or condition differences in CBF values.

  11. Human brain: reliability and reproducibility of pulsed arterial spin-labeling perfusion MR imaging.

    Science.gov (United States)

    Jahng, Geon-Ho; Song, Enmin; Zhu, Xiao-Ping; Matson, Gerald B; Weiner, Michael W; Schuff, Norbert

    2005-03-01

    The Committee of Human Research of the University of California San Francisco approved this study, and all volunteers provided written informed consent. The goal of this study was to prospectively determine the global and regional reliability and reproducibility of noninvasive brain perfusion measurements obtained with different pulsed arterial spin-labeling (ASL) magnetic resonance (MR) imaging methods and to determine the extent to which within-subject variability and random noise limit reliability and reproducibility. Thirteen healthy volunteers were examined twice within 2 hours. The pulsed ASL methods compared in this study differ mainly with regard to magnetization transfer and eddy current effects. There were two main results: (a) Pulsed ASL MR imaging consistently had high measurement reliability (intraclass correlation coefficients greater than 0.75) and reproducibility (coefficients of variation less than 8.5%), and (b) random noise rather than within-subject variability limited reliability and reproducibility. It was concluded that low signal-to-noise ratios substantially limit the reliability and reproducibility of perfusion measurements.

  12. Arterial spin-labelling perfusion MRI and outcome in neonates with hypoxic-ischemic encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Vis, Jill B. de; Hendrikse, Jeroen [University Medical Center Utrecht, Department of Radiology, HP E 01.132, P.O. Box 85500, Utrecht (Netherlands); Petersen, Esben T. [University Medical Center Utrecht, Department of Radiology, HP E 01.132, P.O. Box 85500, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiotherapy, Utrecht (Netherlands); Vries, Linda S. de; Bel, Frank van; Alderliesten, Thomas; Negro, Simona; Groenendaal, Floris; Benders, Manon J.N.L. [Wilhelmina Children' s Hospital/University Medical Center Utrecht, Department of Neonatology, Utrecht (Netherlands)

    2015-01-15

    Hyperperfusion may be related to outcome in neonates with hypoxic-ischemic encephalopathy (HIE). The purpose of this study was to evaluate whether arterial spin labelling (ASL) perfusion is associated with outcome in neonates with HIE and to compare the predictive value of ASL MRI to known MRI predictive markers. Twenty-eight neonates diagnosed with HIE and assessed with MR imaging (conventional MRI, diffusion-weighted MRI, MR spectroscopy [MRS], and ASL MRI) were included. Perfusion in the basal ganglia and thalami was measured. Outcome at 9 or 18 months of age was scored as either adverse (death or cerebral palsy) or favourable. The median (range) perfusion in the basal ganglia and thalami (BGT) was 63 (28-108) ml/100 g/min in the neonates with adverse outcome and 28 (12-51) ml/100 g/min in the infants with favourable outcome (p < 0.01). The area-under-the-curve was 0.92 for ASL MRI, 0.97 for MRI score, 0.96 for Lac/NAA and 0.92 for ADC in the BGT. The combination of Lac/NAA and ASL MRI results was the best predictor of outcome (r {sup 2} = 0.86, p < 0.001). Higher ASL perfusion values in neonates with HIE are associated with a worse neurodevelopmental outcome. A combination of the MRS and ASL MRI information is the best predictor of outcome. (orig.)

  13. Arterial Spin Labeling Perfusion Study in the Patients with Subacute Mild Traumatic Brain Injury.

    Directory of Open Access Journals (Sweden)

    Che-Ming Lin

    Full Text Available This study uses a MRI technique, three-dimension pulse continuous arterial spin labeling (3D-PCASL, to measure the patient's cerebral blood flow (CBF at the subacute stage of mild traumatic brain injury (MTBI in order to analyze the relationship between cerebral blood flow and neurocognitive deficits.To provide the relationship between cortical CBF and neuropsychological dysfunction for the subacute MTBI patients.After MTBI, perfusion MR imaging technique (3D-PCASL measures the CBF of MTBI patients (n = 23 within 1 month and that of normal controls (n = 22 to determine the quantity and location of perfusion defect. The correlation between CBF abnormalities and cognitive deficits was elucidated by combining the results of the neuropsychological tests of the patients.We observed a substantial reduction in CBF in the bilateral frontal and left occipital cortex as compared with the normal persons. In addition, there were correlation between post concussive symptoms (including dizziness and simulator sickness and CBF in the hypoperfused areas. The more severe symptom was correlated with higher CBF in bilateral frontal and left occipital lobes.First, this study determined that despite no significant abnormality detected on conventional CT and MRI studies, hypoperfusion was observed in MTBI group using 3D-PCASL technique in subacute stage, which suggested that this approach may increase sensitivity to MTBI. Second, the correlation between CBF and the severity of post concussive symptoms suggested that changes in cerebral hemodynamics may play a role in pathophysiology underlies the symptoms.

  14. Acute changes in liver tumour perfusion measured non-invasively with arterial spin labelling

    Science.gov (United States)

    Johnson, S Peter; Ramasawmy, Rajiv; Campbell-Washburn, Adrienne E; Wells, Jack A; Robson, Mathew; Rajkumar, Vineeth; Lythgoe, Mark F; Pedley, R Barbara; Walker-Samuel, Simon

    2016-01-01

    Background: Non-invasive measures of tumour vascular perfusion are desirable, in order to assess response to vascular targeting (or modifying) therapies. In this study, hepatic arterial spin labelling (ASL) magnetic resonance imaging (MRI) was investigated to measure acute changes in perfusion of colorectal cancer in the liver, in response to vascular disruption therapy with OXi4503. Methods: SW1222 and LS174T tumours were established in the liver of MF1 nu/nu mice via intrasplenic injection. Perfusion and R2* MRI measurements were acquired with an Agilent 9.4T horizontal bore scanner, before and at 90 min after 40 mg kg−1 OXi4503. Results: A significant decrease in SW1222 tumour perfusion was observed (−43±33%, Pchange in tumour perfusion and the proximity to large vessels, with pre-treatment blood flow predictive of subsequent response. Histological evaluation confirmed the onset of necrosis and evidence of heterogeneous response between tumour deposits. Conclusions: Hepatic ASL-MRI can detect acute response to targeted tumour vascular disruption entirely non-invasively. Hepatic ASL of liver tumours has potential for use in a clinical setting. PMID:27031853

  15. Assessment of vessel permeability by combining dynamic contrast-enhanced and arterial spin labeling MRI.

    Science.gov (United States)

    Liu, Ho-Ling; Chang, Ting-Ting; Yan, Feng-Xian; Li, Cheng-He; Lin, Yu-Shi; Wong, Alex M

    2015-06-01

    The forward volumetric transfer constant (K(trans)), a physiological parameter extracted from dynamic contrast-enhanced (DCE) MRI, is weighted by vessel permeability and tissue blood flow. The permeability × surface area product per unit mass of tissue (PS) in brain tumors was estimated in this study by combining the blood flow obtained through pseudo-continuous arterial spin labeling (PCASL) and K(trans) obtained through DCE MRI. An analytical analysis and a numerical simulation were conducted to understand how errors in the flow and K(trans) estimates would propagate to the resulting PS. Fourteen pediatric patients with brain tumors were scanned on a clinical 3-T MRI scanner. PCASL perfusion imaging was performed using a three-dimensional (3D) fast-spin-echo readout module to determine blood flow. DCE imaging was performed using a 3D spoiled gradient-echo sequence, and the K(trans) map was obtained with the extended Tofts model. The numerical analysis demonstrated that the uncertainty of PS was predominantly dependent on that of K(trans) and was relatively insensitive to the flow. The average PS values of the whole tumors ranged from 0.006 to 0.217 min(-1), with a mean of 0.050 min(-1) among the patients. The mean K(trans) value was 18% lower than the PS value, with a maximum discrepancy of 25%. When the parametric maps were compared on a voxel-by-voxel basis, the discrepancies between PS and K(trans) appeared to be heterogeneous within the tumors. The PS values could be more than two-fold higher than the K(trans) values for voxels with high K(trans) levels. This study proposes a method that is easy to implement in clinical practice and has the potential to improve the quantification of the microvascular properties of brain tumors.

  16. Propofol allows precise quantitative arterial spin labelling functional magnetic resonance imaging in the rat.

    Science.gov (United States)

    Griffin, Karen M; Blau, Christoph W; Kelly, Michael E; O'Herlihy, Colm; O'Connell, P R; Jones, James F X; Kerskens, Christian M

    2010-07-15

    Functional magnetic resonance imaging (fMRI) techniques highlight cerebral vascular responses which are coupled to changes in neural activation. However, two major difficulties arise when employing these techniques in animal studies. First is the disturbance of cerebral blood flow due to anaesthesia and second is the difficulty of precise reproducible quantitative measurements. These difficulties were surmounted in the current study by using propofol and quantitative arterial spin labelling (QASL) to measure relative cerebral blood volume of labelled water (rCBV(lw),) mean transit time (MTT) and capillary transit time (CTT). The ASL method was applied to measure the haemodynamic response in the primary somatosensory cortex following forepaw stimulation in the rat. Following stimulation an increase in signal intensity and rCBV(lw) was recorded, this was accompanied by a significant decrease in MTT (1.97+/-0.06s to 1.44+/-0.04s) and CTT (1.76+/-0.06s to 1.39+/-0.07s). Two animals were scanned repeatedly on two different experimental days. Stimulation in the first animal was applied to the same forepaw during the initial and repeat scan. In the second animal stimulation was applied to different forepaws on the first and second days. The control and activated ASL signal intensities, rCBVlw on both days were almost identical in both animals. The basal MTT and CTT during the second scan were also very similar to the values obtained during the first scan. The MTT recorded from the animal that underwent stimulation to the same paw during both scanning sessions was very similar on the first and second days. In conclusion, propofol induces little physiological disturbance and holds potential for longitudinal QASL fMRI studies.

  17. Multimodality evaluation of dural arteriovenous fistula with CT angiography, MR with arterial spin labeling, and digital subtraction angiography: case report.

    Science.gov (United States)

    Alexander, Matthew; McTaggart, Ryan; Santarelli, Justin; Fischbein, Nancy; Marks, Michael; Zaharchuk, Greg; Do, Huy

    2014-01-01

    Dural arteriovenous fistulae (DAVF) are cerebrovascular lesions with pathologic shunting into the venous system from arterial feeders. Digital subtraction angiography (DSA) has long been considered the gold standard for diagnosis, but advances in noninvasive imaging techniques now play a role in the diagnosis of these complex lesions. Herein, we describe the case of a patient with right-side pulsatile tinnitus and DAVF diagnosed using computed tomography angiography, magnetic resonance with arterial spin labeling, and DSA. Implications for imaging analysis of DAVFs and further research are discussed.

  18. High accuracy of arterial spin labeling perfusion imaging in differentiation of pilomyxoid from pilocytic astrocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Nabavizadeh, S.A.; Assadsangabi, R.; Hajmomenian, M.; Vossough, A. [Perelman School of Medicine of the University of Pennsylvania, Department of Radiology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Santi, M. [Perelman School of Medicine of the University of Pennsylvania, Department of Pathology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States)

    2015-05-01

    Pilomyxoid astrocytoma (PMA) is a relatively new tumor entity which has been added to the 2007 WHO Classification of tumors of the central nervous system. The goal of this study is to utilize arterial spin labeling (ASL) perfusion imaging to differentiate PMA from pilocytic astrocytoma (PA). Pulsed ASL and conventional MRI sequences of patients with PMA and PA in the past 5 years were retrospectively evaluated. Patients with history of radiation or treatment with anti-angiogenic drugs were excluded. A total of 24 patients (9 PMA, 15 PA) were included. There were statistically significant differences between PMA and PA in mean tumor/gray matter (GM) cerebral blood flow (CBF) ratios (1.3 vs 0.4, p < 0.001) and maximum tumor/GM CBF ratio (2.3 vs 1, p < 0.001). Area under the receiver operating characteristic (ROC) curves for differentiation of PMA from PA was 0.91 using mean tumor CBF, 0.95 using mean tumor/GM CBF ratios, and 0.89 using maximum tumor/GM CBF. Using a threshold value of 0.91, the mean tumor/GM CBF ratio was able to diagnose PMA with 77 % sensitivity, 100 % specificity, and a threshold value of 0.7, provided 88 % sensitivity and 86 % specificity. There was no statistically significant difference between the two tumors in enhancement pattern (p = 0.33), internal architecture (p = 0.15), or apparent diffusion coefficient (ADC) values (p = 0.07). ASL imaging has high accuracy in differentiating PMA from PA. The result of this study may have important applications in prognostication and treatment planning especially in patients with less accessible tumors such as hypothalamic-chiasmatic gliomas. (orig.)

  19. Comparison of arterial spin labeling and dynamic susceptibility contrast perfusion MRI in patients with acute stroke.

    Directory of Open Access Journals (Sweden)

    Yen-Chu Huang

    Full Text Available BACKGROUND: The aim of this study was to evaluate whether arterial spin labeling (ASL perfusion magnetic resonance imaging (MRI can reliably quantify perfusion deficit as compared to dynamic susceptibility contrast (DSC perfusion MRI. METHODS: Thirty-nine patients with acute ischemic stroke in the anterior circulation territory were recruited. All underwent ASL and DSC MRI perfusion scans within 30 hours after stroke onset and 31 patients underwent follow-up MRI scans. ASL cerebral blood flow (CBF and DSC time to maximum (T(max maps were used to calculate the perfusion defects. The ASL CBF lesion volume was compared to the DSC Tmax lesion volume by Pearson's correlation coefficient and likewise the ASL CBF and DSC T(max lesion volumes were compared to the final infarct sizes respectively. A repeated measures analysis of variance and least significant difference post hoc test was used to compare the mean lesion volumes among ASL CBF, DSC T(max >4-6 s and final infarct. RESULTS: Mean patient age was 72.6 years. The average time from stroke onset to MRI was 13.9 hours. The ASL lesion volume showed significant correlation with the DSC lesion volume for T(max >4, 5 and 6 s (r = 0.81, 0.82 and 0.80; p5 s (29.2 ml, p6 s (21.8 ml, p5 or 6 s were close to mean final infarct size. CONCLUSION: Quantitative measurement of ASL perfusion is well correlated with DSC perfusion. However, ASL perfusion may overestimate the perfusion defects and therefore further refinement of the true penumbra threshold and improved ASL technique are necessary before applying ASL in therapeutic trials.

  20. Stability of MR brain-perfusion measurement using arterial spin labeling

    Energy Technology Data Exchange (ETDEWEB)

    Petr, Jan; Hofheinz, Frank; Platzek, Ivan; Schramm, Georg; Van Den Hoff, Jorg [Helmholtz-Center Dresden-Rossendorf, PET Center, Institute of Radiopharmaceutical Cancer Research (Germany)

    2015-05-18

    Arterial spin labeling (ASL) is an MR technique for assessment of cerebral blood flow (CBF) that does not require use of contrast agents which makes it a less invasive alternative to the 15O-H2O-PET measurement. The repeatability of ASL has been studied extensively but mainly in young healthy volunteers. We have tested repeatability of ASL under realistic clinical conditions in elderly brain tumor patients acquired with a Philips Ingenuity TF PET/MR in the context of an ongoing 11C-Methionine PET/MR study. Twenty three patients (age 54.8±13.0 y) were scanned on two or more session. The patients underwent 6 weeks of concurrent radiochemotherapy with Temozolomide between the first session and second measurement. The mean relative difference of gray matter CBF was 18.6% between the first two session and 13.0% for the second session and further on. The mean gray matter CBF was 46.6±7.2 mL/min/100 g on the first sessions and there was a significant decrease of 9.8% between first and second session (p=0.027). In summary, the ASL presents measurement of CBF with reasonable repeatability also in elderly patients under clinical conditions when it is not possible to control for all sources of variation. Significant decrease of CBF in healthy tissue was observed after the radiochemotherapy. Prospectively, the ASL data together with the also acquired 11C-Methionine PET will be evaluated regarding their separate and combined ability to predict patient outcome and effectiveness of the performed radiochemotherapy.

  1. Whole-brain perfusion imaging with balanced steady-state free precession arterial spin labeling.

    Science.gov (United States)

    Han, Paul Kyu; Ye, Jong Chul; Kim, Eung Yeop; Choi, Seung Hong; Park, Sung-Hong

    2016-03-01

    Recently, balanced steady-state free precession (bSSFP) readout has been proposed for arterial spin labeling (ASL) perfusion imaging to reduce susceptibility artifacts at a relatively high spatial resolution and signal-to-noise ratio (SNR). However, the main limitation of bSSFP-ASL is the low spatial coverage. In this work, methods to increase the spatial coverage of bSSFP-ASL are proposed for distortion-free, high-resolution, whole-brain perfusion imaging. Three strategies of (i) segmentation, (ii) compressed sensing (CS) and (iii) a hybrid approach combining the two methods were tested to increase the spatial coverage of pseudo-continuous ASL (pCASL) with three-dimensional bSSFP readout. The spatial coverage was increased by factors of two, four and six using each of the three approaches, whilst maintaining the same total scan time (5.3 min). The number of segments and/or CS acceleration rate (R) correspondingly increased to maintain the same bSSFP readout time (1.2 s). The segmentation approach allowed whole-brain perfusion imaging for pCASL-bSSFP with no penalty in SNR and/or total scan time. The CS approach increased the spatial coverage of pCASL-bSSFP whilst maintaining the temporal resolution, with minimal impact on the image quality. The hybrid approach provided compromised effects between the two methods. Balanced SSFP-based ASL allows the acquisition of perfusion images with wide spatial coverage, high spatial resolution and SNR, and reduced susceptibility artifacts, and thus may become a good choice for clinical and neurological studies. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Prognostic value of blood flow measurements using arterial spin labeling in gliomas.

    Directory of Open Access Journals (Sweden)

    Julia Furtner

    Full Text Available The period of event-free survival (EFS within the same histopathological glioma grades may have high variability, mainly without a known cause. The purpose of this study was to reveal the prognostic value of quantified tumor blood flow (TBF values obtained by arterial spin labeling (ASL for EFS in patients with histopathologically proven astrocytomas independent of WHO (World Health Organization grade. Twenty-four patients with untreated gliomas underwent tumor perfusion quantification by means of pulsed ASL in 3T. The clinical history of the patients was retrospectively extracted from the local database. Six patients had to be excluded due to insufficent follow-up data for further evaluation or histopathologically verified oligodendroglioma tumor components. Receiver operating characteristic (ROC curves were used to define an optimal cut-off value of maximum TBF (mTBF values for subgrouping in low-perfused and high-perfused gliomas. Kaplan-Meier curves and Cox proportional hazard regression model were used to determine the prognostic value of mTBF for EFS. An optimal mTBF cut-off value of 182 ml/100 g/min (sensitivity  = 83%, specificity  = 100% was determined. Patients with low-perfused gliomas had significantly longer EFS compared to patients with high-perfused gliomas (p = 0.0012 independent of the WHO glioma grade. Quantified mTBF values obtained by ASL offer a new and totally non-invasive marker to prognosticate the EFS, independently on histopathological tumor grading, in patients with gliomas.

  3. Evaluation of tumor blood flow after feeder embolization in meningiomas by arterial spin-labeling perfusion magnetic resonance imaging.

    Science.gov (United States)

    Kawaji, Hiroshi; Koizumi, Shinichiro; Sakai, Naoto; Yamasaki, Tomohiro; Hiramatsu, Hisaya; Kanoko, Yusuke; Kamiya, Mika; Yamashita, Shuhei; Takehara, Yasuo; Sakahara, Harumi; Namba, Hiroki

    2013-10-01

    Preoperative embolization changes the amount of blood flow and pattern of flow distribution in meningioma. Tumor blood flow was investigated in eight meningioma patients before and after embolization using arterial spin-labeling (ASL) perfusion imaging. Although blood flow was significantly reduced in the whole tumor after embolization, changes in flow distribution patterns varied from one case to another. The findings suggest that evaluation of post-embolization tumor blood flow by ASL perfusion imaging would be useful in the surgical planning of meningioma.

  4. Comparison of cerebral blood flow measurement with [15O]-water positron emission tomography and arterial spin labeling magnetic resonance imaging: A systematic review.

    Science.gov (United States)

    Fan, Audrey P; Jahanian, Hesamoddin; Holdsworth, Samantha J; Zaharchuk, Greg

    2016-05-01

    Noninvasive imaging of cerebral blood flow provides critical information to understand normal brain physiology as well as to identify and manage patients with neurological disorders. To date, the reference standard for cerebral blood flow measurements is considered to be positron emission tomography using injection of the [(15)O]-water radiotracer. Although [(15)O]-water has been used to study brain perfusion under normal and pathological conditions, it is not widely used in clinical settings due to the need for an on-site cyclotron, the invasive nature of arterial blood sampling, and experimental complexity. As an alternative, arterial spin labeling is a promising magnetic resonance imaging technique that magnetically labels arterial blood as it flows into the brain to map cerebral blood flow. As arterial spin labeling becomes more widely adopted in research and clinical settings, efforts have sought to standardize the method and validate its cerebral blood flow values against positron emission tomography-based cerebral blood flow measurements. The purpose of this work is to critically review studies that performed both [(15)O]-water positron emission tomography and arterial spin labeling to measure brain perfusion, with the aim of better understanding the accuracy and reproducibility of arterial spin labeling relative to the positron emission tomography reference standard.

  5. Cerebral Blood Flow Measured by Arterial Spin Labeling MRI as a Preclinical Marker of Alzheimer’s Disease

    Science.gov (United States)

    Wierenga, Christina E.; Hays, Chelsea C.; Zlatar, Zvinka Z.

    2017-01-01

    There is growing recognition that cerebral hypoperfusion is related to the pathogenesis of Alzheimer’s disease (AD), implicating the measurement of cerebral blood flow (CBF) as a possible biomarker of AD. The ability to identify the earliest and most reliable markers of incipient cognitive decline and clinical symptoms is critical to develop effective preventive strategies and interventions for AD. Arterial spin labeling (ASL) magnetic resonance imaging (MRI) measures CBF by magnetically labeling arterial water and using it as an endogenous tracer. Studies using ASL MRI in humans indicate that CBF changes are present several years before the development of the clinical symptoms of AD. Moreover, ASL-measured CBF has been shown to distinguish between cognitively normal individuals, adults at risk for AD, and persons diagnosed with AD. Some studies indicate that CBF may even be sensitive for predicting cognitive decline and conversion to mild cognitive impairment and AD over time. Taken together, evidence suggests that the current staging models of AD biomarker pathology should incorporate early changes in CBF as a useful biomarker, possibly present even earlier than amyloid β accumulation. Though still a research tool, ASL imaging is a promising non-invasive and reliable method with the potential to serve as a future clinical tool for the measurement of CBF in preclinical AD. PMID:25159672

  6. The attention network changes in breast cancer patients receiving neoadjuvant chemotherapy: Evidence from an arterial spin labeling perfusion study

    Science.gov (United States)

    Chen, Xingui; He, Xiaoxuan; Tao, Longxiang; Cheng, Huaidong; Li, Jingjing; Zhang, Jingjie; Qiu, Bensheng; Yu, Yongqiang; Wang, Kai

    2017-01-01

    To investigate the neural mechanisms underlying attention deficits that are related to neoadjuvant chemotherapy in combination with cerebral perfusion. Thirty one patients with breast cancer who were scheduled to receive neoadjuvant chemotherapy and 34 healthy control subjects were included. The patients completed two assessments of the attention network tasks (ANT), neuropsychological background tests, and the arterial spin labeling scan, which were performed before neoadjuvant chemotherapy and after completing chemotherapy. After neoadjuvant chemotherapy, the patients exhibited reduced performance in the alerting and executive control attention networks but not the orienting network (p breast cancer. The results demonstrated that neoadjuvant chemotherapy influences hemodynamic activity in different brain areas through increasing cerebral perfusion, which reduces the attention abilities in breast cancer patients. PMID:28209975

  7. Early-stage differentiation between presenile Alzheimer's disease and frontotemporal dementia using arterial spin labeling MRI

    Energy Technology Data Exchange (ETDEWEB)

    Steketee, Rebecca M.E.; Meijboom, Rozanna; Lugt, Aad van der; Smits, Marion [Erasmus MC - University Medical Center, Department of Radiology, PO Box 2040, Rotterdam (Netherlands); Bron, Esther E.; Klein, Stefan [Erasmus MC - University Medical Center, Biomedical Imaging Group Rotterdam, Departments of Medical Informatics and Radiology, PO Box 2040, Rotterdam (Netherlands); Houston, Gavin C. [GE Healthcare, Hatfield (United Kingdom); Mutsaerts, Henri J.M.M. [Academic Medical Center, Department of Radiology, PO Box 22660, Amsterdam (Netherlands); Mendez Orellana, Carolina P. [Erasmus MC - University Medical Center, Department of Radiology, PO Box 2040, Rotterdam (Netherlands); Erasmus MC - University Medical Center, Department of Neurology, PO Box 2040, Rotterdam (Netherlands); Jong, Frank Jan de; Swieten, John C. van [Erasmus MC - University Medical Center, Department of Neurology, PO Box 2040, Rotterdam (Netherlands)

    2016-01-15

    To investigate arterial spin labeling (ASL)-MRI for the early diagnosis of and differentiation between the two most common types of presenile dementia: Alzheimer's disease (AD) and frontotemporal dementia (FTD), and for distinguishing age-related from pathological perfusion changes. Thirteen AD and 19 FTD patients, and 25 age-matched older and 22 younger controls underwent 3D pseudo-continuous ASL-MRI at 3 T. Gray matter (GM) volume and cerebral blood flow (CBF), corrected for partial volume effects, were quantified in the entire supratentorial cortex and in 10 GM regions. Sensitivity, specificity and diagnostic performance were evaluated in regions showing significant CBF differences between patient groups or between patients and older controls. AD compared with FTD patients had hypoperfusion in the posterior cingulate cortex, differentiating these with a diagnostic performance of 74 %. Compared to older controls, FTD patients showed hypoperfusion in the anterior cingulate cortex, whereas AD patients showed a more widespread regional hypoperfusion as well as atrophy. Regional atrophy was not different between AD and FTD. Diagnostic performance of ASL to differentiate AD or FTD from controls was good (78-85 %). Older controls showed global hypoperfusion compared to young controls. ASL-MRI contributes to early diagnosis of and differentiation between presenile AD and FTD. (orig.)

  8. The effect of black tea and caffeine on regional cerebral blood flow measured with arterial spin labeling

    Science.gov (United States)

    Vidyasagar, Rishma; Greyling, Arno; Draijer, Richard; Corfield, Douglas R; Parkes, Laura M

    2013-01-01

    Black tea consumption has been shown to improve peripheral vascular function. Its effect on brain vasculature is unknown, though tea contains small amounts of caffeine, a psychoactive substance known to influence cerebral blood flow (CBF). We investigated the effects on CBF due to the intake of tea components in 20 healthy men in a double-blinded, randomized, placebo-controlled study. On separate days, subjects received a single dose of 184 mg caffeine (equivalent to one strong espresso coffee), 2,820 mg black tea solids containing 184 mg caffeine (equivalent to 6 cups of tea), 2,820 mg decaffeinated black tea solids, or placebo. The CBF and cerebrovascular reactivity (CVR) to hypercapnia were measured with arterial spin labeled magnetic resonance imaging (MRI) before and 2 hours after administration. We found a significant global reduction with caffeine (20%) and tea (21%) in gray matter CBF, with no effect of decaffeinated tea, suggesting that only caffeine influences CBF acutely. Voxelwise analysis revealed the effect of caffeine to be regionally specific. None of the interventions had an effect on CVR. Additional research is required to conclude on the physiologic relevance of these findings and the chronic effects of caffeine and tea intake on CBF. PMID:23486295

  9. Clinical evaluation of an arterial-spin-labeling product sequence in steno-occlusive disease of the brain.

    Directory of Open Access Journals (Sweden)

    Matthias A Mutke

    Full Text Available INTRODUCTION: In brain perfusion imaging, arterial spin labeling (ASL is a noninvasive alternative to dynamic susceptibility contrast-magnetic resonance imaging (DSC-MRI. For clinical imaging, only product sequences can be used. We therefore analyzed the performance of a product sequence (PICORE-PASL included in an MRI software-package compared with DSC-MRI in patients with steno-occlusion of the MCA or ICA >70%. METHODS: Images were acquired on a 3T MRI system and qualitatively analyzed by 3 raters. For a quantitative analysis, cortical ROIs were placed in co-registered ASL and DSC images. Pooled data for ASL-cerebral blood flow (CBF and DSC-CBF were analyzed by Spearman's correlation and the Bland-Altman (BA-plot. RESULTS: In 28 patients, 11 ASL studies were uninterpretable due to patient motion. Of the remaining patients, 71% showed signs of delayed tracer arrival. A weak correlation for DSC-relCBF vs ASL-relCBF (r = 0.24 and a large spread of values in the BA-plot owing to unreliable CBF-measurement was found. CONCLUSION: The PICORE ASL product sequence is sensitive for estimation of delayed tracer arrival, but cannot be recommended to measure CBF in steno-occlusive disease. ASL-sequences that are less sensitive to patient motion and correcting for delayed blood flow should be available in the clinical setting.

  10. Voxel-Wise Functional Connectomics Using Arterial Spin Labeling Functional Magnetic Resonance Imaging: The Role of Denoising.

    Science.gov (United States)

    Liang, Xiaoyun; Connelly, Alan; Calamante, Fernando

    2015-11-01

    The objective of this study was to investigate voxel-wise functional connectomics using arterial spin labeling (ASL) functional magnetic resonance imaging (fMRI). Since ASL signal has an intrinsically low signal-to-noise ratio (SNR), the role of denoising is evaluated; in particular, a novel denoising method, dual-tree complex wavelet transform (DT-CWT) combined with the nonlocal means (NLM) algorithm is implemented and evaluated. Simulations were conducted to evaluate the performance of the proposed method in denoising images and in detecting functional networks from noisy data (including the accuracy and sensitivity of detection). In addition, denoising was applied to in vivo ASL datasets, followed by network analysis using graph theoretical approaches. Efficiencies cost was used to evaluate the performance of denoising in detecting functional networks from in vivo ASL fMRI data. Simulations showed that denoising is effective in detecting voxel-wise functional networks from low SNR data and/or from data with small total number of time points. The capability of denoised voxel-wise functional connectivity analysis was also demonstrated with in vivo data. We concluded that denoising is important for voxel-wise functional connectivity using ASL fMRI and that the proposed DT-CWT-NLM method should be a useful ASL preprocessing step.

  11. Perfusion imaging of parotid gland tumours: usefulness of arterial spin labeling for differentiating Warthin's tumours

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroki; Watanabe, Haruo [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Kanematsu, Masayuki [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Kajita, Kimihiro [Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Mizuta, Keisuke; Aoki, Mitsuhiro [Gifu University School of Medicine, Department of Otolaryngology, Gifu (Japan); Okuaki, Tomoyuki [Philips Healthcare, Tokyo (Japan)

    2015-11-15

    To assess prospectively the efficacy of arterial spin labelling (ASL) against conventional and diffusion-weighted (DW) MR imaging for differentiating parotid gland tumours. We included 10 pleomorphic adenomas, 12 Warthin's tumours, and nine malignant tumours of the parotid glands. Only tumours larger than 10 mm were included in this study. All parotid gland tumours underwent T1-weighted, T2-weighted, DW, and ASL imaging. Tumour-to-parotid gland signal intensity ratios (SIRs) and apparent diffusion coefficients (ADCs) of solid components were correlated with these pathologies. SIRs on T2-weighted images and ADCs were higher in pleomorphic adenomas than in Warthin's tumours (p <.01) and malignant tumours (p <.01). SIRs on ASL were higher in Warthin's tumours than in pleomorphic adenomas (p <.01) and malignant tumours (p <.05). Az value of SIRs on ASL for differentiating Warthin's tumours from the other pathologies was 0.982. The sensitivity, specificity, and accuracy of SIRs on ASL for the diagnosis of Warthin's tumours at an optimal SIR threshold of over 8.70 were 91.7 %, 94.7 %, and 93.5 %, respectively. ASL with SIR measurements could non-invasively evaluate tumour blood flow of parotid gland tumours and differentiate Warthin's tumours from pleomorphic adenomas and malignant tumours. (orig.)

  12. Arterial spin labeling MR imaging for characterisation of renal masses in patients with impaired renal function: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Pedrosa, Ivan [Beth Israel Deaconess Medical Center and Harvard Medical School, Department of Radiology, Boston, MA (United States); UT Southwestern Medical Center, Department of Radiology, Dallas, TX (United States); Rafatzand, Khashayar; Robson, Philip; Alsop, David C. [Beth Israel Deaconess Medical Center and Harvard Medical School, Department of Radiology, Boston, MA (United States); Wagner, Andrew A. [Beth Israel Deaconess Medical Center and Harvard Medical School, Surgery, Division of Urology, Boston, MA (United States); Atkins, Michael B. [Beth Israel Deaconess Medical Center and Harvard Medical School, Hematology/Oncology, Boston, MA (United States); Rofsky, Neil M. [University of Texas Southwestern Medical Center, Departments of Radiology, Dallas, TX (United States)

    2012-02-15

    To retrospectively evaluate the feasibility of arterial spin labeling (ASL) magnetic resonance imaging (MRI) for the assessment of vascularity of renal masses in patients with impaired renal function. Between May 2007 and November 2008, 11/67 consecutive patients referred for MRI evaluation of a renal mass underwent unenhanced ASL-MRI due to moderate-to-severe chronic or acute renal failure. Mean blood flow in vascularised and non-vascularised lesions and the relation between blood flow and final diagnosis of malignancy were correlated with a 2-sided homogeneous variance t-test and the Fisher Exact Test, respectively. A p value <0.05 was considered statistically significant. Seventeen renal lesions were evaluated in 11 patients (8 male; mean age = 70 years) (range 57-86). The median eGFR was 24 mL/min/1.73 m{sup 2} (range 7-39). The average blood flow of 11 renal masses interpreted as ASL-positive (134 +/- 85.7 mL/100 g/min) was higher than that of 6 renal masses interpreted as ASL-negative (20.5 +/- 8.1 mL/100 g/min)(p = 0.015). ASL-positivity correlated with malignancy (n = 3) or epithelial atypia (n = 1) at histopathology or progression at follow up (n = 7). ASL detection of vascularity in renal masses in patients with impaired renal function is feasible and seems to indicate neoplasia although the technique requires further evaluation. (orig.)

  13. Crossed cerebellar diaschisis after stroke identified noninvasively with cerebral blood flow-weighted arterial spin labeling MRI

    Science.gov (United States)

    Strother, Megan K.; Buckingham, Cari; Faraco, Carlos C.; Arteaga, Daniel; Lu, Pengcheng; Xu, Yaomin; Donahue, Manus J.

    2015-01-01

    Background and Purpose Crossed cerebellar diaschisis (CCD) is most commonly investigated using hemodynamic PET and SPECT imaging. However, noninvasive MRI offers advantages of improved spatial resolution, allowing hemodynamic changes to be compared directly with structural findings and without concerns related to ionizing radiation exposure. The aim of this study was to evaluate relationships between CCD identified from cerebral blood flow (CBF)-weighted arterial spin labeling (ASL) MRI with cerebrovascular reactivity (CVR)-weighted blood oxygenation level dependent (BOLD) MRI, Wallerian degeneration, clinical motor impairment, and corticospinal tract involvement. Methods Subjects (n=74) enrolled in an ongoing observational stroke trial underwent CBF-weighted ASL and hypercapnic CVR-weighted BOLD MRI. Hemispheric asymmetry indices for basal cerebellar CBF, cerebellar CVR, and cerebral peduncular area were compared between subjects with unilateral supratentorial infarcts (n=18) and control subjects without infarcts (n=16). CCD required (1) supratentorial infarct and (2) asymmetric cerebellar CBF (>95% confidence interval relative to controls). Results In CCD subjects (n=9), CVR (p=0.04) and cerebral peduncular area (p < 0.01) were significantly asymmetric compared to controls. Compared to infarct subjects not meeting CCD criteria (n=9), CCD subjects had no difference in corticospinal tract location for infarct (p=1.0) or motor impairment (p=0.08). Conclusions CCD correlated with cerebellar CVR asymmetry and Wallerian degeneration. These findings suggest that noninvasive MRI may be a useful alternative to PET or SPECT to study structural correlates and clinical consequences of CCD following supratentorial stroke. PMID:26724658

  14. The effect of black tea and caffeine on regional cerebral blood flow measured with arterial spin labeling.

    Science.gov (United States)

    Vidyasagar, Rishma; Greyling, Arno; Draijer, Richard; Corfield, Douglas R; Parkes, Laura M

    2013-06-01

    Black tea consumption has been shown to improve peripheral vascular function. Its effect on brain vasculature is unknown, though tea contains small amounts of caffeine, a psychoactive substance known to influence cerebral blood flow (CBF). We investigated the effects on CBF due to the intake of tea components in 20 healthy men in a double-blinded, randomized, placebo-controlled study. On separate days, subjects received a single dose of 184 mg caffeine (equivalent to one strong espresso coffee), 2,820 mg black tea solids containing 184 mg caffeine (equivalent to 6 cups of tea), 2,820 mg decaffeinated black tea solids, or placebo. The CBF and cerebrovascular reactivity (CVR) to hypercapnia were measured with arterial spin labeled magnetic resonance imaging (MRI) before and 2 hours after administration. We found a significant global reduction with caffeine (20%) and tea (21%) in gray matter CBF, with no effect of decaffeinated tea, suggesting that only caffeine influences CBF acutely. Voxelwise analysis revealed the effect of caffeine to be regionally specific. None of the interventions had an effect on CVR. Additional research is required to conclude on the physiologic relevance of these findings and the chronic effects of caffeine and tea intake on CBF.

  15. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier;

    2010-01-01

    Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated...

  16. Early response assessment in patients with multiple myeloma during anti-angiogenic therapy using arterial spin labelling: first clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Fenchel, Michael [Eberhard-Karls University, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Eberhard-Karls University, Department of Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Konaktchieva, Marina [Eberhard-Karls University, Department of Internal Medicine, Gastroenterology, Tuebingen (Germany); Weisel, Katja; Kraus, Sabina [Eberhard-Karls University, Department of Internal Medicine, Hematology, Tuebingen (Germany); Brodoefel, Harald; Claussen, Claus D.; Horger, Marius [Eberhard-Karls University, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2010-12-15

    To determine if arterial-spin-labelling (ASL) MRI can reliably detect early response to anti-angiogenic therapy in patients with multiple myeloma by comparison with clinical/haematological response. Nineteen consecutive patients (10 men; mean age 63.5 {+-} 9.1 years) were included in the present study. Inclusion criteria were diagnosis of stage III multiple myeloma and clinical indication for therapeutical administration of bortezomib or lenalidomide. We performed MRI on 3.0T MR in the baseline setting, 3 weeks after onset of therapy and after 8 weeks. Clinical responses were determined on the basis of international uniform response criteria in correlation with haematological parameters and medium-term patient outcome. MRI studies were performed after approval by the local institutional review board. Fifteen patients responded to anti-myeloma therapy; 4/19 patients were non-responders to therapy. Mean tumour perfusion assessed by ASL-MRI in a reference lesion was 220.7 {+-} 132.5 ml min{sup -1} 100 g{sup -1} at baseline, and decreased to 125.7 {+-} 86.3 (134.5 {+-} 150.9) ml min{sup -1} 100 g{sup -1} 3 (8) weeks after onset of therapy (P < 0.02). The mean decrease in paraproteinaemia at week 3 (8) was 52.3 {+-} 47.7% (58.2 {+-} 58.7%), whereas {beta}2-microglobulinaemia decreased by 20.3 {+-} 53.1% (23.3 {+-} 57.0%). Correlation of ASL perfusion with outcome was significant (P = 0.0037). ASL tumour perfusion measurements are a valuable surrogate parameter for early assessment of response to novel anti-angiogenic therapy. (orig.)

  17. Arterial spin labelling MRI for assessment of cerebral perfusion in children with moyamoya disease: comparison with dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Goetti, Robert [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland); University Hospital Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); O' Gorman, Ruth [University Children' s Hospital Zurich, Center for MR Research, Zurich (Switzerland); Khan, Nadia [University Children' s Hospital Zurich, Moyamoya Center, Division of Neurosurgery, Department of Surgery, Zurich (Switzerland); Kellenberger, Christian J.; Scheer, Ianina [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland)

    2013-05-15

    This study seeks to evaluate the diagnostic accuracy of cerebral perfusion imaging with arterial spin labelling (ASL) MR imaging in children with moyamoya disease compared to dynamic susceptibility contrast (DSC) imaging. Ten children (7 females; age, 9.2 {+-} 5.4 years) with moyamoya disease underwent cerebral perfusion imaging with ASL and DSC on a 3-T MRI scanner in the same session. Cerebral perfusion images were acquired with ASL (pulsed continuous 3D ASL sequence, 32 axial slices, TR = 5.5 s, TE = 25 ms, FOV = 24 cm, matrix = 128 x 128) and DSC (gradient echo EPI sequence, 35 volumes of 28 axial slices, TR = 2,000 ms, TE = 36 ms, FOV = 24 cm, matrix = 96 x 96, 0.2 ml/kg Gd-DOTA). Cerebral blood flow maps were generated. ASL and DSC images were qualitatively assessed regarding perfusion of left and right ACA, MCA, and PCA territories by two independent readers using a 3-point-Likert scale and quantitative relative cerebral blood flow (rCBF) was calculated. Correlation between ASL and DSC for qualitative and quantitative assessment and the accuracy of ASL for the detection of reduced perfusion per territory with DSC serving as the standard of reference were calculated. With a good interreader agreement ({kappa} = 0.62) qualitative perfusion assessment with ASL and DSC showed a strong and significant correlation ({rho} = 0.77; p < 0.001), as did quantitative rCBF (r = 0.79; p < 0.001). ASL showed a sensitivity, specificity and accuracy of 94 %, 93 %, and 93 % for the detection of reduced perfusion per territory. In children with moyamoya disease, unenhanced ASL enables the detection of reduced perfusion per vascular territory with a good accuracy compared to contrast-enhanced DSC. (orig.)

  18. Feasibility of Using Pseudo-Continuous Arterial Spin Labeling Perfusion in a Geriatric Population at 1.5 Tesla.

    Directory of Open Access Journals (Sweden)

    Sigurdur Sigurdsson

    Full Text Available To evaluate the feasibility of using pseudo-continuous arterial spin labeling (pCASL perfusion in a geriatric population at 1.5-Tesla.In 17 participants (mean age 78.8±1.63 years we assessed; 1 inter-session repeatability and reliability of resting state perfusion in 27 brain regions; 2 brain activation using finger-tapping as a means to evaluate the ability to detect flow differences; 3 reliability by comparing cerebral blood flow (CBF with pCASL to CBF with phase contrast (PC-MR.The CBF (mean±standard deviation (SD for the whole brain grey matter (GM was 40.6±8.4 and 41.4±8.7 ml/100g/min for the first and second scan respectively. The within-subject standard deviation (SDw, the repeatability index (RI and intra-class correlation coefficient (ICC across the 27 regions ranged from 1.1 to 7.9, 2.2 to 15.5 and 0.35 to 0.98 respectively. For whole brain GM the SDw, RI and ICC were 1.6, 3.2 and 0.96 respectively. The between-subject standard deviation (SDB was larger than the SDw for all regions. Comparison of CBF at rest and activation on a voxel level showed significantly higher perfusion during finger tapping in the motor- and somatosensory regions. The mean CBF for whole brain GM was 40.6±8.4 ml/100g/min at rest and 42.6±8.6 ml/100g/min during activation. Finally the reliability of pCASL against the reference standard of PC-MR was high (ICC = 0.80. The mean CBF for whole brain measured with PC-MRI was 54.3±10.1 ml/100g/min and 38.3±7.8 ml/100g/min with pCASL.The results demonstrate moderate to high levels of repeatability and reliability for most brain regions, comparable to what has been reported for younger populations. The performance of pCASL at 1.5-Tesla shows that region-specific perfusion measurements with this technique are feasible in studies of a geriatric population.

  19. [Abnormal cerebral blood flow distributions during the post-ictal phase of febrile status epilepticus in three pediatric patients measured by arterial spin labeling perfusion MRI].

    Science.gov (United States)

    Hirano, Keiko; Fukuda, Tokiko

    2016-05-01

    The ability to visualize brain perfusion is important for identifying epileptic foci. We present three pediatric cases showing asymmetrical cerebral blood flow (CBF) distributions during the post-ictal phase of febrile status epilepticus measured by arterial spin labeling (ASL) perfusion MRI. During the acute phase, regional CBF measurements in the areas considered including epileptic foci were higher than in the corresponding area of the contralateral hemisphere, though the exact quantitative value varied between cases. We could not identify the correct epileptogenic foci, because those ASL images were taken after the prolonged and extraordinary activation of neurons in the affected area. During the recovery phase, the differences reduced and the average regional CBF measurement was 54.6 ± 6.1 ml/100 g per minute, which was a little less than the number of previous ASL studies. ASL perfusion MRI imaging provides a method for evaluating regional CBF by using magnetically labeled arterial blood water as an endogenous tracer. With this technique, we can repeatedly evaluate both the brain structure and the level of perfusion at the same time. ASL is noninvasive and easily accessible, and therefore it could become a routine tool for assessment of perfusion in daily practice of pediatric neurology.

  20. Multi-delay arterial spin labeling perfusion MRI in moyamoya disease-comparison with CT perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Rui [Chinese Academy of Sciences, State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Beijing (China); University of Chinese Academy of Sciences, Graduate School, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Los Angeles, CA (United States); Yu, Songlin [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); University of California Los Angeles, Department of Neurology, Los Angeles (United States); Alger, Jeffry R.; Wang, Danny J.J. [University of California Los Angeles, Department of Neurology, Los Angeles (United States); UCLA-Beijing Joint Center for Advanced Brain Imaging, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Los Angeles, CA (United States); Zuo, Zhentao; Wang, Bo [Chinese Academy of Sciences, State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Beijing (China); Chen, Juan [Beijing Hospital, Department of Radiology, Beijing (China); Wang, Rong; Zhao, Jizong [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); An, Jing [Siemens Shenzhen Magnetic Resonance Ltd, Shenzhen (China); Xue, Rong [Chinese Academy of Sciences, State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Beijing (China); UCLA-Beijing Joint Center for Advanced Brain Imaging, Los Angeles, CA (United States)

    2014-05-15

    To present a multi-delay pseudo-continuous ASL (pCASL) protocol that offers simultaneous measurements of cerebral blood flow (CBF) and arterial transit time (ATT), and to study correlations between multi-delay pCASL and CT perfusion in moyamoya disease. A 4 post-labeling delay (PLD) pCASL protocol was applied on 17 patients with moyamoya disease who also underwent CT perfusion imaging. ATT was estimated using the multi-delay protocol and included in the calculation of CBF. ASL and CT perfusion images were rated for lesion severity/conspicuity. Pearson correlation coefficients were calculated across voxels between the two modalities in grey and white matter of each subject respectively and between normalized mean values of ASL and CT perfusion measures in major vascular territories. Significant associations between ASL and CT perfusion were detected using subjective ratings, voxel-wise analysis in grey and white matter and region of interest (ROI)-based analysis of normalized mean perfusion. The correlation between ASL CBF and CT perfusion was improved using the multi-delay pCASL protocol compared to CBF acquired at a single PLD of 2 s (P < 0.05). There is a correlation between perfusion data from ASL and CT perfusion imaging in patients with moyamoya disease. Multi-delay ASL can improve CBF quantification, which could be a prognostic imaging biomarker in patients with moyamoya disease. (orig.)

  1. Nichtinvasive Magnetresonanz- Perfusionsmessung des Gehirns mittels Magnetischer Blutbolusmarkierung (Spin-Labeling)

    OpenAIRE

    Warmuth, Carsten

    2003-01-01

    Arterial spin labeling methods allow to determine quantitative tissue blood flow values noninvasively. Arterial blood is labelled by an inversion pulse and the distribution of this intrinsic tracer is measured using magnetic resonance imaging. Experiments using an extra corporal in-vitro porcine kidney in a MR compatible set-up were carried out to determine the accuracy of blood flow values calculated from arterial spin labeling measurements. In a study of 36 brain tumor patients, spin labeli...

  2. Thyroid perfusion imaging as a diagnostic tool in Graves' disease. Arterial spin labeling magnetic resonance imaging vs. colour-coded Doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Muessig, K. [University Hospital of Duesseldorf (Germany). Dept. of Metabolic Diseases; Leibniz Center for Diabetes Research, Duesseldorf (Germany). Inst. for Clinical Diabetology; University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Schraml, C.; Schwenzer, N.F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology; Rietig, R.; Balletshofer, B. [University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Martirosian, P.; Haering, H.U.; Schick, F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; Claussen, C.D. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology

    2012-12-15

    Purpose: Though increased thyroid perfusion assessed by colour-coded Doppler ultrasound (CDUS) is characteristic of Graves' disease (GD), sometimes perfusion assessment by CDUS is not possible. In these cases, arterial spin labelling (ASL), a novel magnetic resonance imaging (MRI) technique allowing non-invasive thyroid perfusion quantification, may have additional diagnostic value. We aimed to evaluate the potential of ASL-MRI for assessment of increased blood perfusion in patients with GD compared to CDUS. Materials and Methods: Thyroid perfusion was measured by CDUS (volume flow rate calculated from pulsed wave Doppler signals and vessel diameter) and ASL-MRI at 1.5 T in 7 patients with GD and 10 healthy controls. Results: In patients with GD, average perfusion in both thyroid lobes was markedly increased compared to controls. Both techniques applied for volume related perfusion as well as absolute volume flow in thyroid feeding vessels provided similar results (all p = 0.0008). Using a cut-off value of 22 ml/min for the volume flow rate assessed by CDUS in the four feeding vessels allowed discrimination between patients with GD and controls in all cases. After adjusting thyroid perfusion for the differences in organ volume, both CDUS and ASL revealed also complete discrimination between health and disease. Conclusion: Thyroid perfusion measurement by ASL-MRI reliably discriminate GD from normal thyroid glands. In patients in whom thyroid arteries cannot be depicted by CDUS for technical or anatomical reasons, ASL-MRI may have additional diagnostic value. (orig.)

  3. A longitudinal study of cerebral blood flow under hypoxia at high altitude using 3D pseudo-continuous arterial spin labeling

    Science.gov (United States)

    Liu, Wenjia; Liu, Jie; Lou, Xin; Zheng, Dandan; Wu, Bing; Wang, Danny J. J.; Ma, Lin

    2017-01-01

    Changes in cerebral blood flow (CBF) may occur with acute exposure to high altitude; however, the CBF of the brain parenchyma has not been studied to date. In this study, identical magnetic resonance scans using arterial spin labeling (ASL) were performed to study the haemodynamic changes at both sea level and high altitude. We found that with acute exposure to high altitude, the CBF in acute mountain sickness (AMS) subjects was higher (P  0.05) compared with those at sea level. Moreover, magnetic resonance angiography in both AMS and non-AMS subjects showed a significant increase in the cross-sectional areas of the internal carotid, basilar, and middle cerebral arteries on the first day at high altitude. These findings support that AMS may be related to increased CBF rather than vasodilation; these results contradict most previous studies that reported no relationship between CBF changes and the occurrence of AMS. This discrepancy may be attributed to the use of ASL for CBF measurement at both sea level and high altitude in this study, which has substantial advantages over transcranial Doppler for the assessment of CBF. PMID:28240265

  4. Regional and voxel-wise comparisons of blood flow measurements between dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) and arterial spin labeling (ASL) in brain tumors.

    Science.gov (United States)

    White, Carissa M; Pope, Whitney B; Zaw, Taryar; Qiao, Joe; Naeini, Kourosh M; Lai, Albert; Nghiemphu, Phioanh L; Wang, J J; Cloughesy, Timothy F; Ellingson, Benjamin M

    2014-01-01

    The objective of the current study was to evaluate the regional and voxel-wise correlation between dynamic susceptibility contrast (DSC) and arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) measurement of cerebral blood flow (CBF) in patients with brain tumors. Thirty patients with histologically verified brain tumors were evaluated in the current study. DSC-MRI was performed by first using a preload dose of gadolinium contrast, then collecting a dynamic image acquisition during a bolus of contrast, followed by posthoc contrast agent leakage correction. Pseudocontinuous ASL was collected using 30 pairs of tag and control acquisition using a 3-dimensional gradient-echo spin-echo (GRASE) acquisition. All images were registered to a high-resolution anatomical atlas. Average CBF measurements within regions of contrast-enhancement and T2 hyperintensity were evaluated between the two modalities. Additionally, voxel-wise correlation between CBF measurements obtained with DSC and ASL were assessed. Results demonstrated a positive linear correlation between DSC and ASL measurements of CBF when regional average values were compared; however, a statistically significant voxel-wise correlation was only observed in around 30-40% of patients. These results suggest DSC and ASL may provide regionally similar, but spatially different measurements of CBF.

  5. Renal blood flow using arterial spin labelling MRI and calculated filtration fraction in healthy adult kidney donors pre-nephrectomy and post-nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Cutajar, Marica; Clark, Christopher A.; Gordon, Isky [University College London, Imaging and Biophysics Unit, Institute of Child Health, London (United Kingdom); Hilton, Rachel; Olsburgh, Jonathon [Renal Unit, Guy' s and St Thomas' NHS Foundation Trust, London (United Kingdom); Marks, Stephen D. [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Paediatric Nephrology, London (United Kingdom); Thomas, David L. [University College London, Department of Brain Repair and Rehabilitation, Institute of Neurology, London (United Kingdom); Banks, Tina [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Radiology, London (United Kingdom)

    2015-08-15

    Renal plasma flow (RPF) (derived from renal blood flow, RBF) and glomerular filtration rate (GFR) allow the determination of the filtration fraction (FF), which may have a role as a non-invasive renal biomarker. This is a hypothesis-generating pilot study assessing the effect of nephrectomy on renal function in healthy kidney donors. Eight living kidney donors underwent arterial spin labelling (ASL) magnetic resonance imaging (MRI) and GFR measurement prior to and 1 year after nephrectomy. Chromium-51 labelled ethylenediamine tetraacetic acid ({sup 51}Cr-EDTA) with multi-blood sampling was undertaken and GFR calculated. The RBF and GFR obtained were used to calculate FF. All donors showed an increase in single kidney GFR of 24 - 75 %, and all but two showed an increase in FF (-7 to +52 %) after nephrectomy. The increase in RBF, and hence RPF, post-nephrectomy was not as great as the increase in GFR in seven out of eight donors. As with any pilot study, the small number of donors and their relatively narrow age range are potential limiting factors. The ability to measure RBF, and hence RPF, non-invasively, coupled with GFR measurement, allows calculation of FF, a biomarker that might provide a sensitive indicator of loss of renal reserve in potential donors. (orig.)

  6. Pattern of cerebral hyperperfusion in Alzheimer's disease and amnestic mild cognitive impairment using voxel-based analysis of 3D arterial spin-labeling imaging: initial experience

    Directory of Open Access Journals (Sweden)

    Ding B

    2014-03-01

    Full Text Available Bei Ding,1 Hua-wei Ling,1 Yong Zhang,2 Juan Huang,1 Huan Zhang,1 Tao Wang,3 Fu Hua Yan11Department of Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, 2Applied Science Laboratory, GE Healthcare, 3Department of Gerontology, Shanghai Mental Health Center, Shanghai, People's Republic of ChinaPurpose: A three-dimensional (3D continuous pulse arterial spin labeling (ASL technique was used to investigate cerebral blood flow (CBF changes in patients with Alzheimer's disease (AD, amnestic mild cognitive impairment (aMCI, and age- and sex-matched healthy controls.Materials and methods: Three groups were recruited for comparison, 24 AD patients, 17 MCI patients, and 21 age- and sex-matched control subjects. Three-dimensional ASL scans covering the entire brain were acquired with a 3.0 T magnetic resonance scanner. Spatial processing was performed with statistical parametric mapping 8. A second-level one-way analysis of variance analysis (threshold at P<0.05 was performed on the preprocessed ASL data. An average whole-brain CBF for each subject was also included as group-level covariates for the perfusion data, to control for individual CBF variations.Results: Significantly increased CBF was detected in bilateral frontal lobes and right temporal subgyral regions in aMCI compared with controls. When comparing AD with aMCI, the major hyperperfusion regions were the right limbic lobe and basal ganglia regions, including the putamen, caudate, lentiform nucleus, and thalamus, and hypoperfusion was found in the left medial frontal lobe, parietal cortex, the right middle temporo-occipital lobe, and particularly, the left anterior cingulate gyrus. We also found decreased CBF in the bilateral temporo-parieto-occipital cortices and left limbic lobe in AD patients, relative to the control group. aMCI subjects showed decreased blood flow in the left occipital lobe, bilateral inferior temporal cortex, and right middle temporal cortex

  7. In vivo visualization of the PICA perfusion territory with super-selective pseudo-continuous arterial spin labeling MRI.

    Science.gov (United States)

    Hartkamp, Nolan S; De Cocker, Laurens J; Helle, Michael; van Osch, Matthias J P; Kappelle, L Jaap; Bokkers, Reinoud P H; Hendrikse, Jeroen

    2013-12-01

    In this work a method is described to discern the perfusion territories in the cerebellum that are exclusively supplied by either or both vertebral arteries. In normal vascular anatomy the posterior inferior cerebellar artery (PICA) is supplied exclusively by its ipsilateral vertebral artery. The perfusion territories of the vertebral arteries were determined in 14 healthy subjects by means of a super-selective pseudo-continuous ASL sequence on a 3T MRI scanner. Data is presented to show the feasibility of determining the PICA perfusion territory. In 10 subjects it was possible to accurately determine both PICA perfusion territories. In two subjects it was possible to determine the perfusion territory of one PICA. Examples in which it was not possible to accurately determine the PICA territory are also given. Additionally, the high variability of the extent of the PICA territory is illustrated using a statistical map. The posterior surface of the cerebellum is entirely supplied by the PICA in six subjects. The most posterior part of the superior surface is supplied by the PICA in eight subjects, and the inferior half of the anterior surface in six subjects. The inferior part of the vermis is supplied by the PICA in all subjects. Two subjects were found with interhemispheric blood flow to both tonsils from one PICA without contribution from the contralateral PICA. With the method as presented, clinicians may in the future accurately classify cerebellar infarcts according to affected perfusion territories, which might be helpful in the decision whether a stenosis should be considered symptomatic.

  8. Evaluation of the degree of arteriovenous shunting in intracranial arteriovenous malformations using pseudo-continuous arterial spin labeling magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sunwoo, Leonard; Park, Sun-Won [Seoul Metropolitan Government - Seoul National University Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Sohn, Chul-Ho; Yun, Tae Jin; Choi, Seung Hong; Cho, Young Dae; Kim, Ji-hoon; Han, Moon Hee [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Lee, Jong Young [Kangdong Sacred Heart Hospital, Department of Neurosurgery, Seoul (Korea, Republic of); Yi, Kyung Sik [Chungbuk National University Hospital, Department of Radiology, Cheongju (Korea, Republic of); Paek, Sun Ha; Kim, Yong Hwy; Kim, Jin Wook; Chung, Hyun-Tai; Kim, Dong Gyu [Seoul National University Hospital, Department of Neurosurgery, Seoul (Korea, Republic of)

    2015-08-15

    Intracranial arteriovenous malformations (AVMs) display venous signals on arterial spin labeling (ASL) magnetic resonance (MR) imaging due to the presence of arteriovenous shunting. Our aim was to quantitatively correlate AVM signal intensity on ASL with the degree of arteriovenous shunting estimated on digital subtraction angiography (DSA) in AVMs. MR imaging including pseudo-continuous ASL at 3 T and DSA were obtained on the same day in 40 patients with intracranial AVMs. Two reviewers assessed the nidus and venous signal intensities on ASL images to determine the presence of arteriovenous shunting. Interobserver agreement on ASL between the reviewers was determined. ASL signal intensity of the AVM lesion was correlated with AVM size and the time difference between normal and AVM venous transit times measured from the DSA images. Interobserver agreement between two reviewers for nidus and venous signal intensities was excellent (κ = 0.80 and 1.0, respectively). Interobserver agreement regarding the presence of arteriovenous shunting was perfect (κ = 1.0). AVM signal intensity showed a positive relationship with the time difference between normal and AVM venous transit times (r = 0.638, P < 0.001). AVM signal intensity also demonstrated a positive relationship with AVM size (r = 0.561, P < 0.001). AVM signal intensity on ASL in patients with AVM correlates well with the degree of early vein opacification on DSA, which corresponds to the degree of arteriovenous shunting. (orig.)

  9. Arterial spin labeling-fast imaging with steady-state free precession (ASL-FISP): a rapid and quantitative perfusion technique for high-field MRI.

    Science.gov (United States)

    Gao, Ying; Goodnough, Candida L; Erokwu, Bernadette O; Farr, George W; Darrah, Rebecca; Lu, Lan; Dell, Katherine M; Yu, Xin; Flask, Chris A

    2014-08-01

    Arterial spin labeling (ASL) is a valuable non-contrast perfusion MRI technique with numerous clinical applications. Many previous ASL MRI studies have utilized either echo-planar imaging (EPI) or true fast imaging with steady-state free precession (true FISP) readouts, which are prone to off-resonance artifacts on high-field MRI scanners. We have developed a rapid ASL-FISP MRI acquisition for high-field preclinical MRI scanners providing perfusion-weighted images with little or no artifacts in less than 2 s. In this initial implementation, a flow-sensitive alternating inversion recovery (FAIR) ASL preparation was combined with a rapid, centrically encoded FISP readout. Validation studies on healthy C57/BL6 mice provided consistent estimation of in vivo mouse brain perfusion at 7 and 9.4 T (249 ± 38 and 241 ± 17 mL/min/100 g, respectively). The utility of this method was further demonstrated in the detection of significant perfusion deficits in a C57/BL6 mouse model of ischemic stroke. Reasonable kidney perfusion estimates were also obtained for a healthy C57/BL6 mouse exhibiting differential perfusion in the renal cortex and medulla. Overall, the ASL-FISP technique provides a rapid and quantitative in vivo assessment of tissue perfusion for high-field MRI scanners with minimal image artifacts.

  10. Dopaminergic Therapy Modulates Cortical Perfusion in Parkinson Disease With and Without Dementia According to Arterial Spin Labeled Perfusion Magnetic Resonance Imaging.

    Science.gov (United States)

    Lin, Wei-Che; Chen, Pei-Chin; Huang, Yung-Cheng; Tsai, Nai-Wen; Chen, Hsiu-Ling; Wang, Hung-Chen; Lin, Tsu-Kung; Chou, Kun-Hsien; Chen, Meng-Hsiang; Chen, Yi-Wen; Lu, Cheng-Hsien

    2016-02-01

    Arterial spin labeling (ASL) magnetic resonance imaging analyses allow for the quantification of altered cerebral blood flow, and provide a novel means of examining the impact of dopaminergic treatments. The authors examined the cerebral perfusion differences among 17 Parkinson disease (PD) patients, 17 PD with dementia (PDD) patients, and 17 healthy controls and used ASL-MRI to assess the effects of dopaminergic therapies on perfusion in the patients. The authors demonstrated progressive widespread cortical hypoperfusion in PD and PDD and robust effects for the dopaminergic therapies. Specifically, dopaminergic medications further decreased frontal lobe and cerebellum perfusion in the PD and PDD groups, respectively. These patterns of hypoperfusion could be related to cognitive dysfunctions and disease severity. Furthermore, desensitization to dopaminergic therapies in terms of cortical perfusion was found as the disease progressed, supporting the concept that long-term therapies are associated with the therapeutic window narrowing. The highly sensitive pharmaceutical response of ASL allows clinicians and researchers to easily and effectively quantify the absolute perfusion status, which might prove helpful for therapeutic planning.

  11. Simultaneous PET/MR imaging of the brain: feasibility of cerebral blood flow measurements with FAIR-TrueFISP arterial spin labeling MRI

    Energy Technology Data Exchange (ETDEWEB)

    Stegger, Lars [Dept. of Radiology, Diagnostic and Interventional Radiology, Eberhard Karls Univ. Tuebingen, Tuebingen (Germany); Dept. of Nuclear Medicine and European Inst. for Molecular Imaging, Univ. of Munster, Munster (Germany)], E-mail: stegger@uni-muenster.de; Martirosian, Petros; Schick, Fritz [Dept. of Radiology, Section of Experimental Radiology, Eberhard Karls Univ. Tuebingen, Tuebingen (Germany); Schwenzer, Nina; Pfannenberg, Christina; Claussen, Claus D. [Dept. of Radiology, Diagnostic and Interventional Radiology, Eberhard Karls Univ. Tuebingen, Tuebingen (Germany); Bisdas, Sotirios [Dept. of Radiology, Diagnostic and Interventional Neuroradiology, Eberhard Karls Univ. Tuebingen, Tuebingen (Germany); Kolb, Armin; Pichler, Bernd [Dept. of Preclinical Imaging and Radiopharmacy, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Eberhard Karls Univ. Tuebingen, Tuebingen (Germany); Boss, Andreas [Dept. of Radiology, Diagnostic and Interventional Radiology, Eberhard Karls Univ. Tuebingen, Tuebingen (Germany); Inst. of Diagnostic and Interventional Radiology, Univ. Hospital Zurich, Zurich (Switzerland)

    2012-11-15

    Background Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) with simultaneous data acquisition promises a comprehensive evaluation of cerebral pathophysiology on a molecular, anatomical, and functional level. Considering the necessary changes to the MR scanner design the feasibility of arterial spin labeling (ASL) is unclear. Purpose To evaluate whether cerebral blood flow imaging with ASL is feasible using a prototype PET/MRI device. Material and Methods ASL imaging of the brain with Flow-sensitive Alternating Inversion Recovery (FAIR) spin preparation and true fast imaging in steady precession (TrueFISP) data readout was performed in eight healthy volunteers sequentially on a prototype PET/MRI and a stand-alone MR scanner with 128 x 128 and 192 x 192 matrix sizes. Cerebral blood flow values for gray matter, signal-to-noise and contrast-to-noise ratios, and relative signal change were compared. Additionally, the feasibility of ASL as part of a clinical hybrid PET/MRI protocol was demonstrated in five patients with intracerebral tumors. Results Blood flow maps showed good delineation of gray and white matter with no discernible artifacts. The mean blood flow values of the eight volunteers on the PET/MR system were 51 {+-} 9 and 51 {+-} 7 mL/100 g/min for the 128 x 128 and 192 x 192 matrices (stand-alone MR, 57 {+-} 2 and 55 {+-} 5, not significant). The value for signal-to-noise (SNR) was significantly higher for the PET/MRI system using the 192 x 192 matrix size (P < 0.01), the relative signal change (dS) was significantly lower for the 192 x 192 matrix size (P = 0.02). ASL imaging as part of a clinical hybrid PET/MRI protocol could successfully be accomplished in all patients in diagnostic image quality. Conclusion ASL brain imaging is feasible with a prototype hybrid PET/MRI scanner, thus adding to the value of this novel imaging technique.

  12. Simultaneous multi-slice Turbo-FLASH imaging with CAIPIRINHA for whole brain distortion-free pseudo-continuous arterial spin labeling at 3 and 7 T.

    Science.gov (United States)

    Wang, Yi; Moeller, Steen; Li, Xiufeng; Vu, An T; Krasileva, Kate; Ugurbil, Kamil; Yacoub, Essa; Wang, Danny J J

    2015-06-01

    Simultaneous multi-slice (SMS) or multiband (MB) imaging has recently been attempted for arterial spin labeled (ASL) perfusion MRI in conjunction with echo-planar imaging (EPI) readout. It was found that SMS-EPI can reduce the T1 relaxation effect of the label and improve image coverage and resolution with little penalty in signal-to-noise ratio (SNR). However, EPI still suffers from geometric distortion and signal dropout from field inhomogeneity effects especially at high and ultrahigh magnetic fields. Here we present a novel scheme for achieving high fidelity distortion-free quantitative perfusion imaging by combining pseudo-continuous ASL (pCASL) with SMS Turbo-FLASH (TFL) readout at both 3 and 7 T. Bloch equation simulation was performed to characterize and optimize the TFL-based pCASL perfusion signal. Two MB factors (3 and 5) were implemented in SMS-TFL pCASL and compared with standard 2D TFL and EPI pCASL sequences. The temporal SNR of SMS-TFL pCASL relative to that of standard TFL pCASL was 0.76 ± 0.10 and 0.74 ± 0.11 at 7 T and 0.70 ± 0.05 and 0.65 ± 0.05 at 3T for MB factor of 3 and 5, respectively. By implementing background suppression in conjunction with SMS-TFL at 3T, the relative temporal SNR improved to 0.84 ± 0.09 and 0.79 ± 0.10 for MB factor of 3 and 5, respectively. Compared to EPI pCASL, significantly increased temporal SNR (pbrain distortion-free quantitative mapping of cerebral blood flow at high and ultrahigh magnetic fields.

  13. Impact of neonate haematocrit variability on the longitudinal relaxation time of blood: Implications for arterial spin labelling MRI

    Directory of Open Access Journals (Sweden)

    J.B. De Vis

    2014-01-01

    Conclusion: We demonstrated a wide variability of the T1b in neonates and the implications it could have in methods relying on the actual T1b as for instance ASL. It was concluded that arterial-drawn Hct values obtained from a point-of-care device can be used to infer the T1b whereas our data did not support the use of capillary-drawn Hct for T1b correction.

  14. Arterial spin-labeling MR imaging in moyamoya disease compared with clinical assessments and other MR imaging finings

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Tomoyuki, E-mail: tnogucci@radiol.med.kyushu-u.ac.jp [Department of Radiology, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Kawashima, Masatou [Department of Neurosurgery, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Nishihara, Masashi; Hirai, Tetsuyoshi [Department of Radiology, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Matsushima, Toshio [Department of Neurosurgery, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Irie, Hiroyuki [Department of Radiology, Faculty of Medicine, Saga University, 5-1-1, Nabeshima, Saga 849-8501 (Japan)

    2013-12-01

    Purpose: Our purpose was to identify the causal factors for the perfusion distribution obtained with ASL-MRI by comparing ASL-MRI with clinical information and other MRI findings in moyamoya disease. Methods: Seventy-one patients with moyamoya disease underwent ASL-MRI and other MRI, including fluid-attenuated inversion recovery imaging (FLAIR) and three-dimensional time-of-flight magnetic resonance angiography (MRA) on 3.0-Tesla MRI system. Cerebral blood flow (CBF) values (ASL values) for the cerebral hemispheres (142 sides) were measured on CBF maps generated by ASL-MRI. Relationships between the ASL values and the following 9 factors were assessed: sex, family history, revascularization surgery, age at MR exam, age at onset, the steno-occlusive severity on MRA (MRA score), degree of basal collaterals, degree of leptomeningeal high signal intensity seen on FLAIR, and size of ischemic or hemorrhagic cerebrovascular accident lesion (CVA score). Results: Patients with a family history had significantly higher ASL values than those without such a history. There were significant negative correlations between ASL values and age at MR exam, MRA score, and CVA score. Conclusions: ASL-MRI may have cause-and-effect or mutual associations with family history, current patient age, size of CVA lesion, and intracranial arterial steno-occlusive severity in Moyamoya disease.

  15. Correlation between arterial spin labeling MRI and dynamic FDG on PET-MR in Alzheimer’s disease and non-Alzhiemer’s disease patients

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, David; Goubran, Maged; Wilson, Eugene; Xu, Guofan; Tripathi, Pragya; Holley, Dawn; Chao, Steven; Wintermark, Max; Quon, Andrew; Zeineh, Michael; Vasanawala, Minal; Zaharchuk, Greg [Stanford University, California (United States)

    2015-05-18

    Regional hypoperfusion on Arterial Spin Labeling (ASL) MRI and corresponding regions of hypometabolism on FDG PET have been reported in Alzheimer’s Disease (AD). To our knowledge these correlations have not been studied under simultaneous acquisition. The purpose of this study is to investigate the correlation of ASL with FDG PET under simultaneous acquisition on PET-MR and to explore this correlation as a possible biomarker for AD. Dynamic FDG and ASL imaging was performed using a simultaneous TOF-enabled PET-MR scanner in 7 subjects without AD and 3 subjects with AD. Average age was 68±5 years. Automated atlas-based segmentation was performed using T2 MRI using the Talairach atlas. Quantitative analysis of ASL and FDG (delayed 45-75 minute scan) was performed in five regions using the pons as a reference region for both perfusion and metabolism. Statistical analyses included Spearman’s correlation and student’s t-test. Significant correlation of relative perfusion and metabolism was found in two of the five brain regions including the putamen (p = 0.018) and the hippocampus (p = 0.031). In addition, there was significant difference between the relative perfusion and metabolism of the thalamus (p = 0.04). No difference was seen between the AD and non-AD groups. Simultaneous PET-MR demonstrates a positive correlation of perfusion of ASL with metabolism on FDG PET in the hippocampus and putamen. The putamen correlation has previously been reported in the literature on a non-simultaneous ASL and FDG imaging. The thalamus was noted to have a difference in the relative perfusion and metabolism representing a perfusion-metabolism mismatch. Future studies should explore the correlation in additional brain regions and the meaning of perfusion-metabolism mismatches as potential imaging biomarkers for patients with and without AD.

  16. Astrocytic tumour grading: a comparative study of three-dimensional pseudocontinuous arterial spin labelling, dynamic susceptibility contrast-enhanced perfusion-weighted imaging, and diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Hua-Feng [302 Hospital of Chinese People' s Liberation Army, Department of Radiology, Beijing (China); Chen, Zhi-Ye; Wang, Yu-Lin; Wang, Yan; Ma, Lin [People' s Liberation Army General Hospital, Department of Radiology, Beijing (China); Lou, Xin [People' s Liberation Army General Hospital, Department of Radiology, Beijing (China); University of California, Department of Neurology, Los Angeles, CA (United States); Gui, Qiu-Ping [People' s Liberation Army General Hospital, Department of Pathology, Beijing (China); Shi, Kai-Ning; Zhou, Zhen-Yu; Zheng, Dan-Dan [General Electric Healthcare (China) Co., Ltd., Beijing; Wang, Danny J.J. [University of California, Department of Neurology, Los Angeles, CA (United States)

    2015-12-15

    We hypothesized that three-dimensional pseudocontinuous arterial spin labelling (pCASL) may have similar efficacy in astrocytic tumour grading as dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI), and the grading accuracy may be further improved when combined with apparent diffusion coefficient (ADC) values. Forty-three patients with astrocytic tumours were studied using diffusion weighted imaging (DWI), pCASL, and DSC-PWI. Histograms of ADC and normalized tumour cerebral blood flow values (nCBF on pCASL and nrCBF on DSC-PWI) were measured and analyzed. The mean 10 % ADC value was the DWI parameter that provided the best differentiation between low-grade astrocytoma (LGA) and high-grade astrocytoma (HGA). The nCBF and nrCBF (1.810 ± 0.979 and 2.070 ± 1.048) in LGA were significantly lower than those (4.505 ± 2.270 and 5.922 ± 2.630) in HGA. For differentiation between LGA and HGA, the cutoff values of 0.764 x 10{sup -3} mm{sup 2}/s for mean 10 % ADC, 2.374 for nCBF, and 3.464 for nrCBF provided the optimal accuracy (74.4 %, 86.1 %, and 88.6 %, respectively). Combining the ADC values with nCBF or nrCBF could further improve the grading accuracy to 97.7 % or 95.3 %, respectively. pCASL is an alternative to DSC-PWI for astrocytic tumour grading. The combination of DWI and contrast-free pCASL offers a valuable choice in patients with risk factors. (orig.)

  17. Non-invasive assessment of intratumoral vascularity using arterial spin labeling: A comparison to susceptibility-weighted imaging for the differentiation of primary cerebral lymphoma and glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Furtner, J., E-mail: julia.furtner@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Schöpf, V., E-mail: veronika.schoepf@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Preusser, M., E-mail: matthias.preusser@meduniwien.ac.at [Department of Medicine I, Division of Oncology, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Asenbaum, U., E-mail: ulrika.asenbaum@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Woitek, R., E-mail: ramona.woitek@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Wöhrer, A., E-mail: adelheid.woehrer@meduniwien.ac.at [Institute of Neurology, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Hainfellner, J.A., E-mail: johannes.hainfellner@meduniwien.ac.at [Institute of Neurology, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Wolfsberger, S., E-mail: stefan.wolfsberger@meduniwien.ac.at [Department of Neurosurgery, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Prayer, D., E-mail: daniela.prayer@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria)

    2014-05-15

    Using conventional MRI methods, the differentiation of primary cerebral lymphomas (PCNSL) and other primary brain tumors, such as glioblastomas, is difficult due to overlapping imaging characteristics. This study was designed to discriminate tumor entities using normalized vascular intratumoral signal intensity values (nVITS) obtained from pulsed arterial spin labeling (PASL), combined with intratumoral susceptibility signals (ITSS) from susceptibility-weighted imaging (SWI). Thirty consecutive patients with glioblastoma (n = 22) and PCNSL (n = 8), histologically classified according to the WHO brain tumor classification, were included. MRIs were acquired on a 3 T scanner, and included PASL and SWI sequences. nVITS was defined by the signal intensity ratio between the tumor and the contralateral normal brain tissue, as obtained by PASL images. ITSS was determined as intratumoral low signal intensity structures detected on SWI sequences and were divided into four different grades. Potential differences in the nVITS and ITSS between glioblastomas and PCNSLs were revealed using statistical testing. To determine sensitivity, specificity, and diagnostic accuracy, as well as an optimum cut-off value for the differentiation of PCNSL and glioblastoma, a receiver operating characteristic analysis was used. We found that nVITS (p = 0.011) and ITSS (p = 0.001) values were significantly higher in glioblastoma than in PCNSL. The optimal cut-off value for nVITS was 1.41 and 1.5 for ITSS, with a sensitivity, specificity, and accuracy of more than 95%. These findings indicate that nVITS values have a comparable diagnostic accuracy to ITSS values in differentiating glioblastoma and PCNSL, offering a completely non-invasive and fast assessment of tumoral vascularity in a clinical setting.

  18. Changes in cerebral blood flow after transjugular intrahepatic portosystemic shunt can help predict the development of hepatic encephalopathy: An arterial spin labeling MR study

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Gang [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu 210016 (China); Zhang, Long Jiang [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); Wang, Ze [Department of Psychiatry, Perelman School of Medicine, University of Pennsylvania, 3900 Chestnut St., Philadelphia, PA 19104 (United States); Qi, Rong Feng; Shi, Donghong [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); Wang, Li [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu 210016 (China); Fan, Xinxin [Research Institute of General Surgery, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); Lu, Guang Ming, E-mail: kevinzhanglongjiang@yahoo.com.cn [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China)

    2012-12-15

    Background and purpose: Cerebral blood flow (CBF) changes after transjugular intrahepatic portosystemic shunt (TIPS) are still unclear. Our aim is to assess the TIPS-induced CBF changes and their potential clinical significance using the arterial spin labeling (ASL) perfusion magnetic resonance imaging. Materials and methods: Nine cirrhotic patients underwent ASL 1–8 days before and 4–7 days after TIPS. CBF was calculated at each voxel and mean CBF values were computed in the whole brain, gray matter and white matter. Changes of CBFs before and after TIPS were compared by paired t-test. Results: Voxel-wise results showed CBF diffusely increased in patients after TIPS, but no region with significant decrease in CBF was found, nor was any significant mean CBF difference detected in the whole brain, gray matter and white matter. Six patients out of nine showed a global CBF increase of 9–39%; one patient presented a global CBF decrease of 6%; another two showed a global CBF decrease of 16% and 31% respectively. Follow-up studies showed that the two patients with greatly decreased global CBF suffered from multiple episodes of overt hepatic encephalopathy (OHE) after TIPS and one died of OHE. Conclusions: CBF derived from noninvasive ASL MRI could be used as a useful biomarker to predict the development of OHE through consecutively tracking CBF changes in patients with inserted TIPS. Increased CBFs in many cortical regions could be common effects of the TIPS procedure, while decreased global CBF following TIPS might indicate the development of OHE.

  19. Cerebral blood flow measured by arterial-spin labeling MRI: A useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Gang [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu, 210016 (China); Zhang, Long Jiang, E-mail: kevinzhlj@163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Zhong, Jianhui [Department of Imaging Sciences, University of Rochester School of Medicine and Dentistry, Box648, 601 Elmwood Avenue, Rochester, NY 14642-8648 (United States); Wang, Ze [Department of Psychiatry, Perelman School of Medicine, University of Pennsylvania, 3900 Chestnut St., Philadelphia, PA 19104 (United States); Qi, Rongfeng; Shi, Donghong [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Lu, Guang Ming, E-mail: cjr.luguangming@vip.163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China)

    2013-11-01

    Purpose: To investigate the role of arterial-spin labeling (ASL) MRI to non-invasively characterize the patterns of cerebral blood flow (CBF) changes in cirrhotic patients and to assess the potential of ASL MRI to characterize minimal hepatic encephalopathy (MHE). Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Thirty six cirrhosis patients without overt hepatic encephalopathy (16 MHE patients and 20 non hepatic encephalopathy (non-HE) patients) and 25 controls underwent ASL MRI, and CBF was measured for each subject. One-way ANOCOVA test with age and gender as covariences was used to compare CBF difference among three groups, and post hoc analysis was performed between each two groups. Region-based correlation analysis was applied between Child–Pugh score, venous blood ammonia level, neuropsychological tests and CBF values in cirrhosis patients. Receiver operator characteristic (ROC) analysis was used for assessing CBF measurements in ASL MRI to differentiate MHE from non-HE patients. Results: The gray matter CBF of MHE patients (71.09 ± 11.88 mL min{sup −1} 100 g{sup −1}) was significantly higher than that of non-HE patients (55.28 ± 12.30 mL min{sup −1} 100 g{sup −1}, P < 0.01) and controls (52.09 ± 9.27 mL min{sup −1} 100 g{sup −1}, P < 0.001). Voxel-wise ANOCOVA results showed that CBFs were significantly different among three groups in multiple gray matter areas (P < 0.05, Bonferroni corrected). Post hoc comparisons showed that CBF of these brain regions was increased in MHE patients compared with controls and non-HE patients (P < 0.05, Bonferroni corrected). CBF of the right putamen was of the highest sensitivity (93.8%) and moderate specificity (75.0%) for characterization of MHE when using the cutoff value of 50.57 mL min{sup −1} 100 g{sup −1}. CBFs in the bilateral median cingulate gyri, left supramarginal gyrus, right angular gyrus, right

  20. Cross relaxation in nitroxide spin labels

    Science.gov (United States)

    Marsh, Derek

    2016-11-01

    Cross relaxation, and mI -dependence of the intrinsic electron spin-lattice relaxation rate We , are incorporated explicitly into the rate equations for the electron-spin population differences that govern the saturation behaviour of 14N- and 15N-nitroxide spin labels. Both prove important in spin-label EPR and ELDOR, particularly for saturation recovery studies. Neither for saturation recovery, nor for CW-saturation EPR and CW-ELDOR, can cross relaxation be described simply by increasing the value of We , the intrinsic spin-lattice relaxation rate. Independence of the saturation recovery rates from the hyperfine line pumped or observed follows directly from solution of the rate equations including cross relaxation, even when the intrinsic spin-lattice relaxation rate We is mI -dependent.

  1. [Role of rapid movement of spin labels in interpreting EPR spectra for spin-labelled macromolecules].

    Science.gov (United States)

    Nikol'skiĭ, D O; Timofeev, V P

    2003-01-01

    The method of spin labeling was used to monitor quick movements of side residues in protein monocrystals. The EPR spectra of monocrystals of spin-labeled lysozyme at different orientations of the tetrahonal crystal relative to the direction of the magnetic field were interpreted using the molecular dynamics method. A simple model was proposed, which enables one to calculate the trajectory of movements of the spin label by the molecular dynamic method over a relatively short period of time. The entire "frozen" protein molecule and a "defrozen" spin-labeled amino acid residue were considered in the framework of the model. To calculate the trajectories in vacuum, a model of spin-labeled lysozyme was constructed, and the parameters of force potentials for the atoms of the protein molecule and the spin label were specified. It follows from the calculations that the protein environment sterically hinders the range of eventual angular reorientations of the reporter NO-group of nitroxyl incorporated into the spin label, thereby affecting the shape of the EPR spectrum. However, the scatter in the positions of the reporter group in the angular space turned out to correspond to the Gauss distribution. Using the atomic coordinates of the spin label, obtained in a chosen time interval by the method of molecular dynamics, and taking into account the distribution of the states of the spin label in the ensemble of spin-labeled macromolecules in the crystal, we simulated the EPR spectra of monocrystals of spin-labeled lysozyme. The theoretical EPR spectra coincide well with the experimental.

  2. Cross relaxation in nitroxide spin labels

    DEFF Research Database (Denmark)

    Marsh, Derek

    2016-01-01

    -label EPR and ELDOR, particularly for saturation recovery studies. Neither for saturation recovery, nor for CW-saturation EPR and CW-ELDOR, can cross relaxation be described simply by increasing the value of We, the intrinsic spin-lattice relaxation rate. Independence of the saturation recovery rates from...

  3. Application of 3-dimensional Arterial Spin Labeling in Acute Mild Traumatic Brain Injury%3D ASL在急性轻度创伤性脑损伤中的应用

    Institute of Scientific and Technical Information of China (English)

    黄荣慧; 陈长青

    2013-01-01

    To investigate the diagnostic value of the 3-dimensional arterial spin labeling(3D ASL)technology in patients with acute traumatic brain injury,conventional MRI and 3D ASL technology were employed to make brain scan for 43 patients with acute mild traumatic brain injury and 20 healthy volunteers.The results indicated that the status of cerebral brain flow can be detected by 3D ASL rather than conventional MRI.The results from 3D ASL indicated that cerebral brain flow(CBF)value is not obviously different among anterior,middle and posterior cerebral artery area from healthy people(P > 0.05).CBF value of TBI patients without distinct low hypoperfusion area was significantly lower than healthy peoples(P < 0.O1).CBF value of cerebral partial low hypoperfusion area of TBI patients was significantly lower than that of symmetrical side(P < 0.01).Hence it is worth to introduce 3D ASL technology to clinical application because the technology shows significant clinical value in detecting the status of low hypoperfusion area of CBF from acute mild TBI patients.%为了探讨3D动脉自旋标记(arterial spin labeling,ASL)技术对急性创伤性脑损伤(traumatic brain injury,TBI)病人的诊断价值,将43例急性轻度TBI患者和20例健康志愿者进行了常规MRI(magnetic resonance imaging)和3D ASL扫描.结果表明,3D ASL能显示常规MRI所不能显示的脑内血流灌注情况.3D ASL结果发现,健康志愿者组双侧前、中、后动脉供血区的脑血流量(cerebral brain flow,CBF)值比较均无差异(P值均>0.05);TBI患者未出现明显低灌注区的脑实质CBF较志愿者脑实质CBF值明显降低(P值<0.01);TBI患者脑内局部低灌注区较对侧镜面区的CBF值明显减低(P值<0.01).3D ASL技术能检测出急性轻度TBI患者脑实质灌注减低情况,对于临床诊治有重要意义,值得在临床推崇.

  4. Using intravoxel incoherent motion MR imaging to study the renal pathophysiological process of contrast-induced acute kidney injury in rats: Comparison with conventional DWI and arterial spin labelling

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Long; Zhang, Bin [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Southern Medical University, Graduate College, Guangzhou (China); Chen, Wen-bo; Liang, Chang-hong; Zhang, Shui-xing [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Chan, Kannie W.Y.; Li, Yu-guo; Liu, Guan-shu [The Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of MR Research, Baltimore, MD (United States)

    2016-06-15

    To investigate the potential of intravoxel incoherent motion (IVIM) to assess the renal pathophysiological process in contrast-induced acute kidney injury (CIAKI). Twenty-seven rats were induced with CIAKI model, six rats were imaged longitudinally at 24 h prior to and 30 min, 12, 24, 48, 72 and 96 h after administration; three rats were randomly chosen from the rest for serum creatinine and histological studies. D, f, D* and ADC were calculated from IVIM, and renal blood flow (RBF) was obtained from arterial spin labelling (ASL). A progressive reduction in D and ADC was observed in cortex (CO) by 3.07 and 8.62 % at 30 min, and by 25.77 and 28.16 % at 48 h, respectively. A similar change in outer medulla (OM) and inner medulla (IM) was observed at a later time point (12-72 h). D values were strongly correlated with ADC (r = 0.885). As perfusion measurement, a significant decrease was shown for f in 12-48 h and an increase in 72-96 h. A slightly different trend was found for D*, which was decreased by 26.02, 21.78 and 10.19 % in CO, OM and IM, respectively, at 30 min. f and D* were strongly correlated with RBF in the cortex (r = 0.768, r = 0.67), but not in the medulla. IVIM is an effective imaging tool for monitoring progress in renal pathophysiology undergoing CIAKI. (orig.)

  5. Accuracy and precision of pseudo-continuous arterial spin labeling perfusion during baseline and hypercapnia: a head-to-head comparison with ¹⁵O H₂O positron emission tomography.

    Science.gov (United States)

    Heijtel, D F R; Mutsaerts, H J M M; Bakker, E; Schober, P; Stevens, M F; Petersen, E T; van Berckel, B N M; Majoie, C B L M; Booij, J; van Osch, M J P; Vanbavel, E; Boellaard, R; Lammertsma, A A; Nederveen, A J

    2014-05-15

    Measurements of the cerebral blood flow (CBF) and cerebrovascular reactivity (CVR) provide useful information about cerebrovascular condition and regional metabolism. Pseudo-continuous arterial spin labeling (pCASL) is a promising non-invasive MRI technique to quantitatively measure the CBF, whereas additional hypercapnic pCASL measurements are currently showing great promise to quantitatively assess the CVR. However, the introduction of pCASL at a larger scale awaits further evaluation of the exact accuracy and precision compared to the gold standard. (15)O H₂O positron emission tomography (PET) is currently regarded as the most accurate and precise method to quantitatively measure both CBF and CVR, though it is one of the more invasive methods as well. In this study we therefore assessed the accuracy and precision of quantitative pCASL-based CBF and CVR measurements by performing a head-to-head comparison with (15)O H₂O PET, based on quantitative CBF measurements during baseline and hypercapnia. We demonstrate that pCASL CBF imaging is accurate during both baseline and hypercapnia with respect to (15)O H₂O PET with a comparable precision. These results pave the way for quantitative usage of pCASL MRI in both clinical and research settings.

  6. Pseudocontact shifts from mobile spin labels

    CERN Document Server

    Suturina, E

    2016-01-01

    This paper presents a detailed analysis of the pseudocontact shift (PCS) field induced by a mobile spin label that is viewed as a probability density distribution with an associated magnetic susceptibility. It is demonstrated that anisotropy in this density can lead to significant deviations from the commonly used point dipole approximation for PCS. Analytical and numerical solutions are presented for the general partial differential equation that describes the non-point case. It is also demonstrated that it is possible to reconstruct paramagnetic centre probability distributions from experimental PCS data.

  7. EPR spin Hamiltonian parameters of encapsulated spin-labels: impact of the hydrogen bonding topology.

    Science.gov (United States)

    Frecus, Bogdan; Rinkevicius, Zilvinas; Murugan, N Arul; Vahtras, Olav; Kongsted, Jacob; Ågren, Hans

    2013-02-21

    Encapsulation of spin-labels into "host" compounds, like cucurbit[n]urils or cyclodextrins, in solutions has profound effects on the EPR spin Hamiltonian parameters of the spin-labels. In this work we study the microscopic origin of the EPR spin Hamiltonian parameters of spin-labels enclosed in hydrophobic cavities. We focus on the dependence of the EPR properties of encapsulated spin-labels on the hydrogen bonding topologies that occur upon encapsulation, and quantize various contributions to these parameters according to specific hydrogen bonding patterns. The obtained results provide refined insight into the role of the hydrogen bonding induced encapsulation shifts of EPR spin Hamiltonian parameters in solvated "spin-label@host compound" complexes.

  8. Application of Arterial Spin Labeling (ASL) Technique in the Pre Operative Evaluation of Brain Tumors%动脉自旋标记技术在脑肿瘤术前评估中的应用研究

    Institute of Scientific and Technical Information of China (English)

    朱记超; 娄明武; 张方璟; 赖文娟; 胡卫东; 范义; 陈燕萍

    2012-01-01

    目的 对比研究动态磁敏感对比增强(dynamic susceptibility contrast-enhanced,DSC) MRI及动脉自旋标记(aterial spin labeling,ASL)技术在脑肿瘤术前评估中的作用,探讨ASL技术在脑肿瘤术前评估中的应用价值. 方法 经病理证实的41例脑肿瘤患者,其中高级别胶质瘤8例,低级别胶质瘤16例,转移瘤7例,脑膜瘤10例.采用3.0TMR扫描仪行ASL流动敏感交互反转恢复(flow-sensitive alternating inversion recovery,FAIR)法及DSC灌注检查,将原始图像分析处理后分别获取肿瘤实性区域、瘤周1 cm及2 cm区域血流灌注指标平均最大相对脑血流量(rCBFmax)比值.所得数据经统计学处理,P<0.05为差异有统计学意义;对两种技术所得平均rCBFmax比值行线性回归分析,得出其相关系数,了解其相关性.结果 在肿瘤实性区域,两种技术所得rCBFmax低级别胶质瘤组与其他各组间差异均有统计学意义(P<0.05);在瘤旁1 cm区域,DSC技术所得rCBFmax高级别胶质瘤组与其他各组间差异均有统计学意义(P<0.05),而ASL技术rCBFmax在各组差异无统计学意义(P>0.05).两种技术所得rCBFmax在各组脑肿瘤瘤区实性区域与瘤旁1 cm及2 cm区域差异均有统计学意义(P<0.05).两种技术于肿瘤实性区域所得灌注指标显著正相关(r =0.907).结论 ASL技术是一种无需注射对比剂的MR灌注方法,可考虑作为常规检查方法评估脑肿瘤血流动力学情况,指导脑肿瘤术前级别评估.%Objective To explore the potential clinical application of arterial spin labeling (ASL) technique in the pre operative evaluation of brain tumors comparing with DSC MR imaging. Methods Forty one cases of brain tumors, including 8 high grade gliomas, 16 low grade gliomas, 7 metastases, and 10 meningiomas, performed flow-sensitive alternating inversion recovery(FAIR) and dynamic susceptibility contrast-enhanced (DSC) at a clinical 3.0 T MR imaging unit. All the cases were verified

  9. 动脉自旋标记灌注成像技术在脑胶质瘤术前评估中的应用%Application of arterial spin labeling for preoperative evaluation of gliomas

    Institute of Scientific and Technical Information of China (English)

    王敏; 王德杭; 洪汛宁; 张清波; 王建伟; 刘波

    2011-01-01

    目的 探讨动脉自旋标记(ASL)灌注成像技术在脑胶质瘤中的临床应用价值.方法 使用3.OT MR 成像系统对23例脑胶质瘤患者(术后病理证实高级别胶质瘤14例,低级别胶质瘤9例)术前行常规扫描外,加扫ASL灌注检查,分析不同级别胶质瘤MR灌注表现,测量肿瘤实质部分最大肿瘤血流量(TBFmax)以及对侧白质、灰质、半球的血流量(CBF).结果 在AsL灌注图像中,高级别胶质瘤呈明显的高血流灌注,低级别胶质瘤呈低血流灌注.高、低级胶质瘤TBFmax/对侧白质CBF的比值分别为6.32±2.79、3.00±1.66(P<0.01);TBFmax/对侧灰质CBF的比值分别为1.25±0.66、0.65±0.45(P<0.05);TBFmax/对侧半球CBF的比值分别为4.10±1.92、1.86±1.57(P<0.01).结论 ASL可用于评估脑胶质瘤的微血管灌注,有助于术前对脑胶质瘤进行分级评判.%Objective To investigate the clinical value of arterial spin labeling(ASL) technique for preoperatively evaluating microvascular perfusion of gliomas. Methods Twenty-three patients with gliomas(with histological diagnosis of high-grade gliomas in 14 cases and low-grade gliomas in 9 cases) were routimely examined by 3.0T MRI including ASL before operation. The maximal tumor blood flow (TBFmax) and the cerebral blood flow(CBF) of opposite white matter, grey matter and hemisphere were measured on maps. Results On the ASL maps, high grade glioma showed a higher microvascular perfusion and low grade glioma showed a lower microvascular perfusion. The ratios of TBFmax to CBF of opposite white matter were 6. 32± 2. 79 for high grade and 3. 00± 1.66 for low grade(P<0. 01) ,which of opposite grey matter were 1.25±0.66 and 0. 65±0. 45(P<0. 05) and of opposite hemisphere were 4.10±1.92 and 1.86±1.57(P<0.01), respectively. Conclusion ASL may be a suitable method for the evaluation of microvascular perfusion, and is helpful in grading gliomas.

  10. Cerebrovascular reactivity by using arterial spin-labeling magnetic resonance imaging in subcortical ischemic vascular disease%皮质下缺血性血管病脑血管反应性磁共振研究

    Institute of Scientific and Technical Information of China (English)

    舒敏; 章军建; 高永哲; 张洪; 吴光耀

    2014-01-01

    目的:通过观察皮质下缺血性血管病(SIVD)患者不同脑区局部脑血管反应性(CVR)的变化及认知功能的损害,探讨 SIVD 局部 CVR 的改变在认知功能损害中的作用。方法:采用动脉自旋标记(ASL)磁共振灌注技术定量测定 SIVD 患者与对照组吸入5% CO2前后额叶、颞叶、顶叶、枕叶皮质和白质局部血流量(rCBF),CVR 采用前后2次各兴趣区 rCBF 的增加率表示。结果:(1) SIVD 组额叶皮质及白质、颞叶白质、枕叶白质的 CVR 比对照组显著降低(P <0.05)。(2) SIVD 组有认知功能损害患者和无认知功能损害患者相比额叶皮质、额叶白质 CVR 下降明显(P <0.01)。结论:SIVD 患者存在广泛的脑血管自动调节功能受损,并且额叶皮质、白质的 CVR 下降与认知功能损害有关。%Objective To assess regional cerebrovascular reactivity (CVR) and cognition impairment of subcortical ischemic vascular disease (SIVD). To show whether CVR affects cognitive impairment of SIVD patients. Methods Arterial spin-labeling (ASL) by MR image was applied in measuring regional cerebral blood flow (rCBF) of frontal lobe, temporal lobe, parietal lobe, occipital lobes after 5% CO2 inhalation, and the CVR was demonstrated by increase rate of rCBF in all the subject areas. Results (1)The patients with SIVD had reduced CVR in cortex of frontal lobes, white matter of frontal lobes, temporal lobes and occipital lobes(P < 0.05). (2) CVR in the SIVD patients with cognitive impairment decreased in frontal cortex and white matter when compared with the patients without cognitive impairment(P < 0.01). Conclusion These results showed that CVR decreased significantly in cortical gray matter and white matter in elderly patients with SIVD. Also the reduction of CVR in the frontal cortex and white matter was associated with cognitive impairment.

  11. Application of ESR spin label oximetry in food science.

    Science.gov (United States)

    Zhou, Yu-Ting; Yin, Jun-Jie; Lo, Y Martin

    2011-12-01

    Lipid oxidation attributed to the presence of oxygen has long been a focal area for food science research due in early years mainly to its broad impact on the quality and shelf stability. The need to effectively strategize interventions to detect and eventually eliminate lipid oxidation in food remains as evidence on nutritional and health implications continue to accumulate. Electron spin resonance (ESR) spin label oximetry has been shown capable of detecting dissolved oxygen concentration in both liquid and gaseous phases based on the collision between oxygen and stable free radicals. This review aimed to summarize not just the principles and rationale of ESR spin label oximetry but also the wide spectrum of ESR spin label oximetry applications to date. The feasibility to identify in very early stage oxygen generation and consumption offers a promising tool for controlling lipid oxidation in food and biological systems.

  12. Spin-labelled vacuolar-ATPase inhibitors in lipid membranes.

    Science.gov (United States)

    Dixon, Neil; Páli, Tibor; Kee, Terence P; Marsh, Derek

    2004-10-11

    Two spin-labelled derivatives of the 5-(2-indolyl)-2,4-pentadienoyl class of inhibitors of the vacuolar ATPase have been synthesised and their EPR properties characterised in phospholipid membranes. One spin-labelled inhibitor is the amide derivative of pentadienic acid and 4-amino-TEMPO (INDOL6), and the other is the 3-hydroxymethyl-PROXYL ester (INDOL5). The response of the EPR spectra to the chain-melting transition of dimyristoyl phosphatidylcholine (DMPC) bilayers demonstrates that both derivatives incorporate in phospholipid membranes. The axially anisotropic EPR spectra of INDOL6 in fluid DMPC membranes indicate that the indolyl-pentadienoyl inhibitors intercalate between the lipid chains, in the membrane. INDOL5, designed to possess additional internal segmental mobility, exhibits more nearly isotropic motion of the spin-label moiety in fluid membranes than does INDOL6. The EPR characteristics of INDOL5 are therefore well suited to detecting specific ligand-protein interactions. Progressive saturation EPR experiments with polar and hydrophobic relaxation agents (aqueous Ni2+ and oxygen) show that the nitroxide group is buried in the membrane, with the indole moiety providing the anchor at the membrane polar-apolar interface. Rates of spin-label reduction by externally added ascorbate confirm this assignment. These two spin-labelled derivatives provide complementary EPR probes of the lipid environment (INDOL6), and of ligand-protein interactions (INDOL5), for this class of V-ATPase inhibitor.

  13. Nuclear spin-lattice relaxation in nitroxide spin-label EPR

    DEFF Research Database (Denmark)

    Marsh, Derek

    2016-01-01

    Nuclear relaxation is a sensitive monitor of rotational dynamics in spin-label EPR. It also contributes competing saturation transfer pathways in T1-exchange spectroscopy, and the determination of paramagnetic relaxation enhancement in site-directed spin labelling. A survey shows that the definit......Nuclear relaxation is a sensitive monitor of rotational dynamics in spin-label EPR. It also contributes competing saturation transfer pathways in T1-exchange spectroscopy, and the determination of paramagnetic relaxation enhancement in site-directed spin labelling. A survey shows...... that the definition of nitrogen nuclear relaxation rate Wn commonly used in the CW-EPR literature for 14N-nitroxyl spin labels is inconsistent with that currently adopted in time-resolved EPR measurements of saturation recovery. Redefinition of the normalised 14N spin-lattice relaxation rate, b = Wn/(2We), preserves...... the expressions used for CW-EPR, whilst rendering them consistent with expressions for saturation recovery rates in pulsed EPR. Furthermore, values routinely quoted for nuclear relaxation times that are deduced from EPR spectral diffusion rates in 14N-nitroxyl spin labels do not accord with conventional analysis...

  14. Technological advances in site-directed spin labeling of proteins.

    Science.gov (United States)

    Hubbell, Wayne L; López, Carlos J; Altenbach, Christian; Yang, Zhongyu

    2013-10-01

    Molecular flexibility over a wide time range is of central importance to the function of many proteins, both soluble and membrane. Revealing the modes of flexibility, their amplitudes, and time scales under physiological conditions is the challenge for spectroscopic methods, one of which is site-directed spin labeling EPR (SDSL-EPR). Here we provide an overview of some recent technological advances in SDSL-EPR related to investigation of structure, structural heterogeneity, and dynamics of proteins. These include new classes of spin labels, advances in measurement of long range distances and distance distributions, methods for identifying backbone and conformational fluctuations, and new strategies for determining the kinetics of protein motion.

  15. The role of the fast motion of the spin label in the interpretation of EPR spectra for spin-labeled macromolecules.

    Science.gov (United States)

    Timofeev, Vladimir P; Nikolsky, Dmitriy O

    2003-12-01

    The spin label method was used to observe the nature of the fast motions of side chains in protein monocrystals. The EPR spectra of spin-labeled lysozyme monocrystals (with different orientations of the tetragonal protein crystal in relation to the direction of the magnetic field) were interpreted using the method of molecular dynamics (MD). Within the proposed simple model, MD calculations of the spin label motion trajectories are performed in a reasonable real time. The model regards the protein molecule as frozen as a whole and the spin-labeled amino acid residue as unfrozen. To calculate the trajectories in vacuum, a model of spin-labeled lysozyme was assembled, and the parameters of the force fields were specified for atoms of the protein molecule, including the spin label. The calculations show that the protein environment sterically limits the area of the possible angular reorientations for the NO reporter group of the nitroxide (within the spin label), and this, in turn, affects the shape of the EPR spectrum. However, it turned out that the spread in the positions of the reporter group in the angle space strictly adheres to the Gaussian distribution. Using the coordinates of the spin label atoms obtained by the MD method within a selected time range and considering the distribution of the spin label states over the ensemble of spin-labeled macromolecules in a crystal, the EPR spectra of spin-labeled lysozyme monocrystals were simulated. The resultant theoretical EPR spectra appeared to be similar to experimental ones.

  16. Pulsed EPR in the method of spin labels and probes

    Energy Technology Data Exchange (ETDEWEB)

    Dzuba, Sergei A [Institute of Chemical Kinetics and Combustion, Siberian Branch of the Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2007-08-31

    Various pulsed EPR in the method of spin labels and probes based on electron spin echo spectroscopy (spin echo envelope modulation through electron-nuclear interactions, electron-electron double resonance, echo detected EPR, etc.) are considered. These methods provide information on the conformations of complex biomolecules, nanostructure of matter, depth of water penetration into biological membranes, supramolecular structure of multicomponent systems (membrane-peptide, etc.), co-operative orientational dynamics of molecules and dynamic low-temperature transitions in disordered molecular media and biosystems.

  17. Pulsed eldor measurement of nitrogen T1 in spin labels

    Science.gov (United States)

    Hyde, James S.; Froncisz, W.; Mottley, C.

    1984-10-01

    A 180° pulse is delivered to one hyperfine line of a nitroxide spin label, and the arrival and disappearance of saturation at another hyperfine line is monitored with a second microwave field. Electron and nitrogen nuclear relaxation times are found to be in poor agreement ,vith the electron-nuclear dipolar (END) mechanism.

  18. Nuclear spin-lattice relaxation in nitroxide spin-label EPR

    Science.gov (United States)

    Marsh, Derek

    2016-11-01

    Nuclear relaxation is a sensitive monitor of rotational dynamics in spin-label EPR. It also contributes competing saturation transfer pathways in T1-exchange spectroscopy, and the determination of paramagnetic relaxation enhancement in site-directed spin labelling. A survey shows that the definition of nitrogen nuclear relaxation rate Wn commonly used in the CW-EPR literature for 14N-nitroxyl spin labels is inconsistent with that currently adopted in time-resolved EPR measurements of saturation recovery. Redefinition of the normalised 14N spin-lattice relaxation rate, b = Wn/(2We), preserves the expressions used for CW-EPR, whilst rendering them consistent with expressions for saturation recovery rates in pulsed EPR. Furthermore, values routinely quoted for nuclear relaxation times that are deduced from EPR spectral diffusion rates in 14N-nitroxyl spin labels do not accord with conventional analysis of spin-lattice relaxation in this three-level system. Expressions for CW-saturation EPR with the revised definitions are summarised. Data on nitrogen nuclear spin-lattice relaxation times are compiled according to the three-level scheme for 14N-relaxation: T1n = 1/Wn. Results are compared and contrasted with those for the two-level 15N-nitroxide system.

  19. A spin label study of conformational changes in cytochrome c.

    Science.gov (United States)

    Postnikova, G B; Gorbunova, N P; Volkenstein, M V

    1983-04-01

    Spin-labeled pig heart cytochromes c singly modified at Met-65, Tyr-74 and at one of the lysine residues, Lys-72 or Lys-73, were investigated by the ESR method under conditions of different ligand and redox states of the heme and at various pH values. Replacement of Met-80 by the external ligand, cyanide, was shown to produce a sharp increase in the mobility of all the three bound labels while reduction of the spin-labeled ferricytochromes c did not cause any marked changes in their ESR spectra. In the pH range 6-13, two conformational transitions in ferricytochrome c were observed which preceded its alkaline denaturation: the first with pK 9.3 registered by the spin label at the Met-65 position, and the second with pK 11.1 registered by the labels bound to Tyr-74 and Lys-72(73). The conformational changes in the 'left-hand part' of ferricytochrome c are most probably induced in both cases by the exchange of internal protein ligands at the sixth coordination site of the heme.

  20. Spin-locking and cross-polarization under magic-angle spinning of uniformly labeled solids.

    Science.gov (United States)

    Hung, Ivan; Gan, Zhehong

    2015-07-01

    Spin-locking and cross-polarization under magic-angle spinning are investigated for uniformly (13)C and (15)N labeled solids. In particular, the interferences from chemical shift anisotropy, and (1)H heteronuclear and (13)C homonuclear dipolar couplings are identified. The physical origin of these interferences provides guidelines for selecting the best (13)C and (15)N polarization transfer rf fields. Optimal settings for both the zero- and double-quantum cross-polarization transfer mechanisms are recommended.

  1. Comparison of arterial spin labeling and dynamic susceptibility contrast-enhanced MR imaging for the preoperation evaluation of tumor grade in brain gliomas%3.0T MR动脉自旋标记与动态磁敏感对比增强灌注技术在脑胶质瘤术前分级中的对照研究

    Institute of Scientific and Technical Information of China (English)

    王敏; 王德杭; 洪汛宁; 王建伟

    2011-01-01

    Objective:To compare the arterial spin labeling and dynamic susceptibility contrast-enhanced MR imaging and explore the clinical application of arterial spin labeling (ASL) technique in the preoperation of tumor grade in brain gliomas. Methods: Twenty-three patients with gliomas ( all the cases were verified histologically, including 17 patients of highgrade gliomas, 6 patients of low-grade gliomas) were routinely examined by 3. 0 T MRI including ASL and DSC before operation. The maximal cerebral blood flow of solid regions of tumor (TBFmax) and the cerebral blood flow of opposite white matter, opposite grey matter and opposite hemisphere were measured on maps. Results: All of 23 cases demonstrated agreement between ASL and DSC MR imagings. The ratio of TBFmax/ opposite white matter CBF, TBFmax/opposite there was statistical difference between high-grade and low-grade gliomas. The threshold of TBFmax/opposite white matter CBF, TBFmax/opposite grey matter CBF, TBF max/opposite hemisphere CBF were 3. 06 , 0. 46 and 1. 31 respectively, the diagnosis sensibility were 100%, 88. 2% and lOO% respectively, and the specificity were 83. 3%, 83. 3% and 100 % respectively by ASL technique. Conclusion : The noninvasive and repcatable ASL technique was almost as sensitive as DSC MRI in detecting brain gliomas perfusing abnormaliries. It is helpful to give the grade of gliomas before operation.%目的:对照研究动脉自旋标记(arterial spin labeling,ASL)与动态磁敏感对比增强(dynamic susceptibility contrast-enhanced,DSC)灌注成像技术在脑胶质瘤中的灌注特点,探讨ASL在脑胶质瘤术前分级中的临床应用价值.方法:使用3.0T MR成像系统对23例脑胶质瘤患者(术后病理证实高级别胶质瘤17例,低级别胶质瘤6例)术前行常规扫描外,加扫ASL及DSC灌注检查,测量肿瘤实质部分最大肿瘤血流量(maximal tumor blood flow,TBFmax)以及对侧白质、对侧灰质、对侧半球的血流量(cerebral blood

  2. Low microwave-amplitude ESR spectroscopy: measuring spin-relaxation interactions of moderately immobilized spin labels in proteins.

    Science.gov (United States)

    Hedin, Eva M K; Hult, Karl; Mouritsen, Ole G; Høyrup, Pernille

    2004-08-31

    Electron spin resonance (ESR) spectroscopy in combination with site-directed spin labeling (SDSL) is a powerful tool for determining protein structure, dynamics and interactions. We report here a method for determining interactions between spin labels and paramagnetic relaxation agents, which is performed under subsaturating conditions. The low microwave-field amplitude employed (h(1)spin-spin-relaxation time, T(2e), is measured by this method, and compared to classical progressive power saturation performed on a free spin label, (1-oxyl-2,2,5,5-tetramethyl-Delta(3)-pyrroline-3-methyl)methanethiosulfonate (MTSL), and a spin-labeled protein (Thermomyces lanuginosa lipase, TLL-I252C), employing the water-soluble relaxation agent chromium(III) oxalate (Crox) in concentrations between 0-10 mM. The low-amplitude theory showed excellent agreement with that of classical power saturation in quantifying Crox-induced relaxation enhancement. Low-amplitude measurements were then performed using a standard resonator, with Crox, on 11 spin-labeled TLL mutants displaying rotational correlation times in the motional narrowing regime. All spin-labeled proteins exhibited significant changes in T(2e). We postulate that this novel method is especially suitable for studying moderately immobilized spin labels, such as those positioned at exposed sites in a protein. This method should prove useful for research groups with access to any ESR instrumentation.

  3. Peptide-membrane Interactions by Spin-labeling EPR

    Science.gov (United States)

    Smirnova, Tatyana I.; Smirnov, Alex I.

    2016-01-01

    Site-directed spin labeling (SDSL) in combination with Electron Paramagnetic Resonance (EPR) spectroscopy is a well-established method that has recently grown in popularity as an experimental technique, with multiple applications in protein and peptide science. The growth is driven by development of labeling strategies, as well as by considerable technical advances in the field, that are paralleled by an increased availability of EPR instrumentation. While the method requires an introduction of a paramagnetic probe at a well-defined position in a peptide sequence, it has been shown to be minimally destructive to the peptide structure and energetics of the peptide-membrane interactions. In this chapter, we describe basic approaches for using SDSL EPR spectroscopy to study interactions between small peptides and biological membranes or membrane mimetic systems. We focus on experimental approaches to quantify peptide-membrane binding, topology of bound peptides, and characterize peptide aggregation. Sample preparation protocols including spin-labeling methods and preparation of membrane mimetic systems are also described. PMID:26477253

  4. Larmor labeling of neutron spin using superconducting Wollaston prisms

    Science.gov (United States)

    Li, Fankang

    Neutron spin Larmor labeling using magnetic Wollaston prisms (WP) provides a way to overcome some of the limitations arising from the nature of neutron beams: low flux and divergence. Using superconducting films and tapes, a series of strong, well-defined shaped magnetic fields can be produced due to both the zero-resistance and Meissner effect in superconductors. Using finite element simulations, the criterion to build a superconducting magnetic Wollaston prism with high encoding efficiency and low Larmor phase aberrations are presented. To achieve a high magnetic field and simplify the maintenance, we optimize the design using careful thermal analysis. The measured neutron spin flipping efficiency is measured to be independent of both the neutron wavelength and energizing current, which is a significant improvement over other devices with similar functions. A highly linear variation of the Larmor phase is measured across the device, which ensures a highly uniform encoding of scattering angles into the neutron spin Larmor phase. Using two WPs, the correlation function for a colloidal silica sample was measured by spin echo modulated small angle neutron scattering (SEMSANS) and agrees well with other techniques. Using Monte Carlo code (McStas), we further investigated the SEMSANS setup and showed the requirements to improve its performance. We have proposed a new technique to implement neutron spin echo on a triple axis neutron spectrometer to achieve high resolution measurements of the lifetime of dispersive phonon excitations. The spin echo is tuned by appropriate choice of magnetic fields instead of physically tilting the coils used in traditional methods. This new approach allows a higher energy resolution and a larger effective tilting angle and hence larger group velocity to be measured.

  5. Analysis of anisotropic spin-label motion in saturation-transfer ESR spectra of spin-labeled cowpea chlorotic mottle virus

    Science.gov (United States)

    Hemminga, M. A.; Faber, A. J.

    A saturation-transfer ESR study is carried out on maleimide spin-labeled cowpea chlorotic mottle virus dissolved in various glycerol-water systems. The saturation-transfer ESR spectra were analyzed by comparing them with reference spectra of isotropically reorienting spin labels. The results are interpreted in terms of the overall motion of the virus particle, described by an isotropic rotational correlation time τR, and a local anisotropic spin-label motion with rotational correlation times τ| and τ⊥.

  6. Spin-labeled gramicidin a: channel formation and dissociation.

    Science.gov (United States)

    Dzikovski, Boris G; Borbat, Petr P; Freed, Jack H

    2004-11-01

    Gramicidin A was studied by continuous wave electron spin resonance (CW-ESR) and by double-quantum coherence electron spin resonance (DQC-ESR) in several lipid membranes (using samples that were macroscopically aligned by isopotential spin-dry ultracentrifugation) and vesicles. As a reporter group, the nitroxide spin-label was attached at the C-terminus yielding the spin-labeled product (GAsl). ESR spectra of aligned membranes containing GAsl show strong orientation dependence. In DPPC and DSPC membranes at room temperature the spectral shape is consistent with high ordering, which, in conjunction with the observed high polarity of the environment of the nitroxide, is interpreted in terms of the nitroxide moiety being close to the membrane surface. In contrast, spectra of GAsl in DMPC membranes indicate deeper embedding and tilt of the NO group. The GAsl spectrum in the DPPC membrane at 35 degrees C (the gel to Pbeta phase transition) exhibits sharp changes, and above this temperature becomes similar to that of DMPC. The dipolar spectrum from DQC-ESR clearly indicates the presence of pairs in DMPC membranes. This is not the case for DPPC, rapidly frozen from the gel phase; however, there are hints of aggregation. The interspin distance in the pairs is 30.9 A, in good agreement with estimates for the head-to-head GAsl dimer (the channel-forming conformation), which matches the hydrophobic thickness of the DMPC bilayer. Both DPPC and DSPC, apparently as a result of hydrophobic mismatch between the dimer length and bilayer thickness, do not favor the channel formation in the gel phase. In the Pbeta and Lalpha phases of DPPC (above 35 degrees C) the channel dimer forms, as evidenced by the DQC-ESR dipolar spectrum after rapid freezing. It is associated with a lateral expansion of lipid molecules and a concomitant decrease in bilayer thickness, which reduces the hydrophobic mismatch. A comparison with studies of dimer formation by other physical techniques indicates the

  7. Effects of Spin-Labels on Membrane Burial Depth of MARCKS-ED Residues.

    Science.gov (United States)

    Qi, Yifei; Klauda, Jeffery B; Im, Wonpil

    2016-10-18

    Site-directed spin-labeling electron paramagnetic resonance spectroscopy is a useful tool to obtain information about the environment of specific residues. One of its applications is to investigate membrane protein topology based on the accessibility of the spin label, with the assumption that the position of the spin label in the membrane is close to that of the native residue. This assumption is valid in proteins with well-ordered structures, but could be problematic in small peptides because the labeling may cause a perturbation that is large enough to change local interactions between the peptide and the membrane. To quantitatively characterize such effects, we have simulated the association of a 25-amino-acid peptide, MARCKS-ED, to membranes with and without spin labels. Our simulations show that the depths of spin labels are ∼6-17 Å deeper than the unlabeled charged and polar residues in the wild-type. When the hydrophobic residue Phe is labeled, however, the spin-label depth is close to that of the native residue as well as the experimental value. Our study suggests that one should be cautious in interpretation of spin label data when charged and polar residues in small peptides are labeled.

  8. RosettaEPR: rotamer library for spin label structure and dynamics.

    Directory of Open Access Journals (Sweden)

    Nathan S Alexander

    Full Text Available An increasingly used parameter in structural biology is the measurement of distances between spin labels bound to a protein. One limitation to these measurements is the unknown position of the spin label relative to the protein backbone. To overcome this drawback, we introduce a rotamer library of the methanethiosulfonate spin label (MTSSL into the protein modeling program Rosetta. Spin label rotamers were derived from conformations observed in crystal structures of spin labeled T4 lysozyme and previously published molecular dynamics simulations. Rosetta's ability to accurately recover spin label conformations and EPR measured distance distributions was evaluated against 19 experimentally determined MTSSL labeled structures of T4 lysozyme and the membrane protein LeuT and 73 distance distributions from T4 lysozyme and the membrane protein MsbA. For a site in the core of T4 lysozyme, the correct spin label conformation (Χ1 and Χ2 is recovered in 99.8% of trials. In surface positions 53% of the trajectories agree with crystallized conformations in Χ1 and Χ2. This level of recovery is on par with Rosetta performance for the 20 natural amino acids. In addition, Rosetta predicts the distance between two spin labels with a mean error of 4.4 Å. The width of the experimental distance distribution, which reflects the flexibility of the two spin labels, is predicted with a mean error of 1.3 Å. RosettaEPR makes full-atom spin label modeling available to a wide scientific community in conjunction with the powerful suite of modeling methods within Rosetta.

  9. 磁共振动脉自旋标记成像在阿尔茨海默病脑血流灌注的研究%Measurement of Cerebral Blood Flow Using Arterial Spin Labeling Magnetic Resonance Imaging in Patients with Alzheimer‘s Disease

    Institute of Scientific and Technical Information of China (English)

    张娜; 樊东升

    2013-01-01

    目的:应用全脑3D 伪连续动脉自旋标记(pcASL)磁共振成像技术对阿尔茨海默病(AD)患者的脑血流灌注特点进行初步研究.方法:16例AD患者(AD组)和16例年龄匹配的认知功能正常老年人(对照组)进行核磁共振形态学和ASL 灌注成像检查.利用SPM8 软件对获得的脑血流图像进行预处理并统计分析,比较2组的脑血流灌注差异,并探讨AD患者的脑血流特点.结果:与对照组相比,AD组内侧颞叶萎缩明显,双侧额颞顶枕血流灌注普遍减低(P<0.001),主要累及左侧额叶、右侧眶额下部、右侧海马旁回、双侧顶叶下部、右侧顶叶上部、右侧缘上回、右侧楔前叶、右侧中扣带回、左侧中央后回、右侧颞叶中部(P=0.000).经部分容积校正后,AD组双侧颞叶及顶枕交界区脑血流灌注明显减低(P<0.001).结论:3DpcASL通过测定脑血流可以监测AD 患者脑功能变化.%Objective: To investigate cerebral blood flow (CBF) characteristics in patients with Alzheimer' s disease by using a whole-brain 3D pseudocontinuous arterial spin-labeling technique. Methods: Sixteen AD patients and 16 age-matched cognitively normal control subjects were studied at 3.0T MR system. CBF maps were preprocessed by SPM8 software and compared by two-sample t test between the AD and control groups. Results: Patients with AD showed lower CBF values compared with that in control group throughout the brain (P<0.001), most prominently in the following regions: frontal lobe (L), inferior orbitofrontal (R), parahippocampal (R), inferior parietal (R and L), anterior parietal (R), supermarginal (R), precunei (R), middle cingulated (R), postcentral (R) and middle temporal (R) (P=0.000). Regarding partial volume effects, corrected CBF in patients with AD decreased obviously in bilateral temporal gyris and parieto-occipital border zones (P<0.001). Conlusion: 3D pseudo-continuous arterial spin labeling imaging technique can monitor brain function by

  10. Detection of atomic spin labels in a lipid bi-layer using a single-spin nanodiamond probe

    CERN Document Server

    Kaufmann, Stefan; Hall, Liam T; Perunicic, Viktor; Senn, Philipp; Steinert, Steffen; McGuinness, Liam P; Johnson, Brett C; Ohshima, Takeshi; Caruso, Frank; Wrachtrup, Joerg; Scholten, Robert E; Mulvaney, Paul; Hollenberg, Lloyd C L

    2013-01-01

    Magnetic field fluctuations arising from fundamental spins are ubiquitous in nanoscale biology, and are a rich source of information about the processes that generate them. However, the ability to detect the few spins involved without averaging over large ensembles has remained elusive. Here we demonstrate the detection of gadolinium spin labels in an artificial cell membrane under ambient conditions using a single-spin nanodiamond sensor. Changes in the spin relaxation time of the sensor located in the lipid bilayer were optically detected and found to be sensitive to near-individual proximal gadolinium atomic labels. The detection of such small numbers of spins in a model biological setting, with projected detection times of one second, opens a new pathway for in-situ nanoscale detection of dynamical processes in biology.

  11. Saturation-transfer ESR spectroscopy on maleimide spin-labeled cowpea chlorotic mottle virus

    Science.gov (United States)

    Vriend, G.; Schilthuis, J. G.; Verduin, B. J. M.; Hemminga, M. A.

    1984-07-01

    One of the two SH groups of the coat protein of Cowpea chlorotic mottle virus (CCMV) was spin-labeled with 3-maleimido-2,2,5,5-tetramethyl-l-pyrrolodinyloxyl. Both electron spin resonance and saturation-transfer electron spin resonance spectra were recorded of intact CCMV and CCMV in which the protein subunits are cross-linked with glutaraldehyde. From an analysis of these spectra it follows that the spin label performs a local anisotropic motion with respect to the protein to which it is attached. It is also concluded that no internal protein mobility is present on the ST-ESR timescale.

  12. Intra-and Inter-Scanner Test-Retest Reliability in Pseudo-continuous Arterial Spin-labeling MR Imaging of Auditory Cortex Perfusion in Healthy Adults%正常成人听皮层磁共振动脉自旋标记灌注成像的可重复性研究

    Institute of Scientific and Technical Information of China (English)

    娄昕; 吴冰; 吴新淮; 纵亮; 黄点点; 王秋菊; 马林

    2013-01-01

    Objective To assess intra-and inter-scanner test-retest reliability in 3D whole-brain pseudo-continu⁃ous arterial spin labeling (pCASL) of the auditory cortex in healthy adults. Methods Eight healthy subjects were scanned three times on two 3.0T MR scanners with 3D whole-brain pCASL technique. The 1st and 3rd tests were done on Scanner 1 and the 2nd test on Scanner 2. Intervals between tests were 10~15 days. Two sets of ASL data with post labeling delay time (PLD) at 1.5 or 2.5 seconds were acquired during each test. Volumetric T1-weighted images of the whole brain were also ac⁃quired for image registration. Cerebral blood flow (CBF) values of the auditory cortex were extracted for comparison. The in⁃tra-and inter-scanner test-retest reliability was evaluated with the intraclass correlation coefficient (ICC) and Bland-Alt⁃man plots. Results Overall, the auditory cortex CBF value was 51~61 ml/min/100g for PLD=1.5s and 43~54 ml/min/100g for PLD=2.5s. For PLD=1.5s, the ICC was 0.50 for comparison between the 1st and 2nd tests, 0.83 for comparison between the 2nd and 3rd tests, and 0.85 for comparison between the 1st and 3rd tests. For PLD=2.5s, the ICC was 0.76 for comparison be⁃tween the 1st and 2nd tests, 0.89 for comparison between the 2nd and 3rd tests and 0.88 for comparison between the 1st and 3rd tests. Bland-Altman plots indicated better reproducibility for PLD=2.5s than for PLD=1.5s. Conclusions The 3D whole-brain pCASL technique can be used for measuring CBF in the auditory cortex with high test-retest reliability, which indicates its value in MR research on blood flow of the auditory cortex across multiple centers.%  目的研究正常成人听皮层磁共振三维动脉自旋标记灌注成像(three dimensional arterial spin labeling,3D ASL)技术的可重复性.方法8例健康成年人在2台同一机型的3.0T磁共振扫描仪上进行了3次全脑3D ASL序列扫描,在1号扫描仪上进行第1次和第3次扫描,在2

  13. Arterial spin labeling perfusion MRI in cerebral ischaemia

    NARCIS (Netherlands)

    Bokkers, R.P.H.

    2011-01-01

    Cerebral perfusion is the basis for the delivery of oxygen and nutrients to the brain. Brain tissue can become damaged when there is a shortage in the blood supply. Basic physiological functions such as synaptic transmission, the membrane ion pump and energy metabolism are disrupted and within minut

  14. Imaging of cerebral hemodynamics with arterial spin labeling

    NARCIS (Netherlands)

    Hartkamp, N.S.

    2014-01-01

    A knowledge of the cerebral circulation is of great importance in the understanding cerebrovascular disease. The ability to visualize the brain vasculature has become key in the diagnosis and treatment of cerebrovascular disease. Modern imaging modalities, such as digital subtraction angiography, co

  15. Bipolar tetraether lipids: chain flexibility and membrane polarity gradients from spin-label electron spin resonance.

    Science.gov (United States)

    Bartucci, R; Gambacorta, A; Gliozzi, A; Marsh, D; Sportelli, L

    2005-11-15

    Membranes of thermophilic Archaea are composed of unique tetraether lipids in which C40, saturated, methyl-branched biphytanyl chains are linked at both ends to polar groups. In this paper, membranes composed of bipolar lipids P2 extracted from the acidothermophile archaeon Sulfolobus solfataricus are studied. The biophysical basis for the membrane formation and thermal stability is investigated by using electron spin resonance (ESR) of spin-labeled lipids. Spectral anisotropy and isotropic hyperfine couplings are used to determine the chain flexibility and polarity gradients, respectively. For comparison, similar measurements have been carried out on aqueous dispersions of diacyl reference lipid dipalmitoyl phosphatidylcholine and also of diphytanoyl phosphatidylcholine, which has methyl-branched chains. At a given temperature, the bolaform lipid chains are more ordered and less flexible than in normal bilayer membranes. Only at elevated temperatures (80 degrees C) does the flexibility of the chain environment in tetraether lipid assemblies approach that of fluid bilayer membranes. The height of the hydrophobic barrier formed by a monolayer of archaebacterial lipids is similar to that in conventional fluid bilayer membranes, and the permeability barrier width is comparable to that formed by a bilayer of C16 lipid chains. At a mole ratio of 1:2, the tetraether P2 lipids mix well with dipalmitoyl phosphatidylcholine lipids and stabilize conventional bilayer membranes. The biological as well as the biotechnological relevance of the results is discussed.

  16. Studying lipid-protein interactions with electron paramagnetic resonance spectroscopy of spin-labeled lipids.

    Science.gov (United States)

    Páli, Tibor; Kóta, Zoltán

    2013-01-01

    Spin label electron paramagnetic resonance (EPR) of lipid-protein interactions reveals crucial features of the structure and assembly of integral membrane proteins. Spin label EPR spectroscopy is the technique of choice to characterize the protein-solvating lipid shell in its highly dynamic nature, because the EPR spectra of lipids that are spin labeled close to the terminal methyl end of their acyl chains display two spectral components, those corresponding to lipids directly contacting the protein and those corresponding to lipids in the bulk fluid bilayer regions of the membrane. In this chapter, typical spin label EPR procedures are presented that allow determination of the stoichiometry of interaction of spin-labeled lipids with the intra-membranous region of membrane proteins or polypeptides, as well as the association constant of the spin-labeled lipid with respect to the host lipid. The lipids giving rise to the so-called immobile spectral component in the EPR spectrum of such samples are identified as the motionally restricted first-shell lipids solvating membrane proteins in biomembranes. Stoichiometry and selectivity are directly related to the structure of the intra-membranous sections of membrane-associated proteins or polypeptides and can be used to study the state of assembly of such proteins in the membrane. Since these characteristics of lipid-protein interactions are discussed in detail in the literature [see Marsh (Eur Biophys J 39:513-525, 2010) for a most recent review], here we focus more on how to spin label model and biomembranes and how to measure and analyze the two-component EPR spectra of spin-labeled lipids in phospholipid bilayers that contain proteins or polypeptides. After a description of how to prepare spin-labeled model and native biological membranes, we present the reader with computational procedures for determining the molar fraction of motionally restricted lipids when both, one, or none of the pure isolated-mobile or

  17. Orthogonal spin labeling using click chemistry for in vitro and in vivo applications

    Science.gov (United States)

    Kucher, Svetlana; Korneev, Sergei; Tyagi, Swati; Apfelbaum, Ronja; Grohmann, Dina; Lemke, Edward A.; Klare, Johann P.; Steinhoff, Heinz-Jürgen; Klose, Daniel

    2017-02-01

    Site-directed spin labeling for EPR- and NMR spectroscopy has mainly been achieved exploiting the specific reactivity of cysteines. For proteins with native cysteines or for in vivo applications, an alternative coupling strategy is required. In these cases click chemistry offers major benefits by providing a fast and highly selective, biocompatible reaction between azide and alkyne groups. Here, we establish click chemistry as a tool to target unnatural amino acids in vitro and in vivo using azide- and alkyne-functionalized spin labels. The approach is compatible with a variety of labels including reduction-sensitive nitroxides. Comparing spin labeling efficiencies from the copper-free with the strongly reducing copper(I)-catalyzed azide-alkyne click reaction, we find that the faster kinetics for the catalyzed reaction outrun reduction of the labile nitroxide spin labels and allow quantitative labeling yields within short reaction times. Inter-spin distance measurements demonstrate that the novel side chain is suitable for paramagnetic NMR- or EPR-based conformational studies of macromolecular complexes.

  18. A spin label study of the effects of asbestos, quartz, and titanium dioxide dusts on the bovine erythrocyte membrane.

    OpenAIRE

    Leyko, W; Gendek, E

    1985-01-01

    The effects of five UICC asbestos samples, titanium dioxide, and quartz on the bovine red cell membrane have been studied in erythrocyte ghosts by the spin labelling technique. Analysis of the electron paramagnetic resonance (EPR) spectra of two sulphydryl reactive spin labels and one fatty acid spin label in red cell ghosts showed modifications in membrane protein after asbestos treatment but no alterations in membrane lipids. In experiments with quartz no membrane changes were noted but tit...

  19. A spin label study of the effects of asbestos, quartz, and titanium dioxide dusts on the bovine erythrocyte membrane.

    Science.gov (United States)

    Leyko, W; Gendek, E

    1985-04-01

    The effects of five UICC asbestos samples, titanium dioxide, and quartz on the bovine red cell membrane have been studied in erythrocyte ghosts by the spin labelling technique. Analysis of the electron paramagnetic resonance (EPR) spectra of two sulphydryl reactive spin labels and one fatty acid spin label in red cell ghosts showed modifications in membrane protein after asbestos treatment but no alterations in membrane lipids. In experiments with quartz no membrane changes were noted but titanium dioxide altered the proteins bound with the protein reactive spin label used in the present study. The possible mechanism for these effects is discussed.

  20. 三维动脉自旋标记脑血流灌注加权成像在交叉性小脑神经机能联系不能的应用价值%Application of three-dimensional arterial spin labeling cerebral blood flow perfusion imaging in crossed cerebellar diaschisis

    Institute of Scientific and Technical Information of China (English)

    黄泽春; 汪文胜; 成丽娜; 谢甜甜; 李松涛; 欧阳兵; 颜刘清; 陈楷哲

    2015-01-01

    Objective To evaluate the use of three-dimensional arterial spin labeling perfusion weighted imaging (3D ASL) in the diagnosis of crossed cerebellar diaschisis (CCD) role by observing the whole brain perfusion of cerebral blood flow,. and to investigate the relationship between the primary brain lesions with CCD. Methods Tha data of 58 cases with supratentorial lesions associated with unilateral middle cerebral artery blood supply combined with contralateral cerebellar hemisphere hypoperfusion were collected..The cerebral blood flow of bilateral cerebellar hemisphere cerebellar was measured using 3D ASL and the asymmetry index (AI) was calculated. CCD was diagnosed if the AI was greater than 10%..The correlations between supratentorial lesion and CCD was analyzed..Results In 58 cases with unilateral supratentorial lesions supplied by middle cerebral artery resulted in contralateral hypoperfusion in infratentorial cerebellar hemisphere, especially in the lower part of cerebellar hemisphere. 55 of the unilateral supratentorial lesions were cerebral infarction, 3 were brain injury. All the supratentorial lesions involved the white matter along the cortex-pons-cerebellar tract..The lower CBF valued in the supratentorial brain tissue and the lower CBF valued in the contralateral cerebellar hemisphere,.which showed a positive correlation..There was no correlation between the occurrence of CCD and the size of low perfusion in supratentorial brain tissue..ASL was done twice in 4 patients and 3 times in 2 patients,.and there was no obvious changes of the CBF in the cerebellum CCD lesion hemisphere..CCD occurred during 1 day and 1 years 2 months after the disease..The occurrence of CCD was related to the location of supratentorial cerebral lesions and not related to the time of onset and duration..Conclusion As a new perfusion method,.3D ASL,.is capable of noninvasive evaluating the occurrence of CCD,.which has a good diagnostic value and can quantitatively assess the degree

  1. Introduction to Spin Label Electron Paramagnetic Resonance Spectroscopy of Proteins

    Science.gov (United States)

    Melanson, Michelle; Sood, Abha; Torok, Fanni; Torok, Marianna

    2013-01-01

    An undergraduate laboratory exercise is described to demonstrate the biochemical applications of electron paramagnetic resonance (EPR) spectroscopy. The beta93 cysteine residue of hemoglobin is labeled by the covalent binding of 3-maleimido-proxyl (5-MSL) and 2,2,5,5-tetramethyl-1-oxyl-3-methyl methanethiosulfonate (MTSL), respectively. The excess…

  2. Label-free Imaging of Arterial Cells and Extracellular Matrix Using a Multimodal CARS Microscope.

    Science.gov (United States)

    Wang, Han-Wei; Le, Thuc T; Cheng, Ji-Xin

    2008-04-01

    A multimodal nonlinear optical imaging system that integrates coherent anti-Stokes Raman scattering (CARS), sum-frequency generation (SFG), and two-photon excitation fluorescence (TPEF) on the same platform was developed and applied to visualize single cells and extracellular matrix in fresh carotid arteries. CARS signals arising from CH(2)-rich membranes allowed visualization of endothelial cells and smooth muscle cells of the arterial wall. Additionally, CARS microscopy allowed vibrational imaging of elastin and collagen fibrils which are also rich in CH(2) bonds. The extracellular matrix organization were further confirmed by TPEF signals arising from elastin's autofluorescence and SFG signals arising from collagen fibrils' non-centrosymmetric structure. Label-free imaging of significant components of arterial tissues suggests the potential application of multimodal nonlinear optical microscopy to monitor onset and progression of arterial diseases.

  3. Toward the fourth dimension of membrane protein structure: insight into dynamics from spin-labeling EPR spectroscopy.

    Science.gov (United States)

    McHaourab, Hassane S; Steed, P Ryan; Kazmier, Kelli

    2011-11-09

    Trapping membrane proteins in the confines of a crystal lattice obscures dynamic modes essential for interconversion between multiple conformations in the functional cycle. Moreover, lattice forces could conspire with detergent solubilization to stabilize a minor conformer in an ensemble thus confounding mechanistic interpretation. Spin labeling in conjunction with electron paramagnetic resonance (EPR) spectroscopy offers an exquisite window into membrane protein dynamics in the native-like environment of a lipid bilayer. Systematic application of spin labeling and EPR identifies sequence-specific secondary structures, defines their topology and their packing in the tertiary fold. Long range distance measurements (60 Å-80 Å) between pairs of spin labels enable quantitative analysis of equilibrium dynamics and triggered conformational changes. This review highlights the contribution of spin labeling to bridging structure and mechanism. Efforts to develop methods for determining structures from EPR restraints and to increase sensitivity and throughput promise to expand spin labeling applications in membrane protein structural biology.

  4. A Facile Synthesis of Spin Labeled 4'-Epi-N-Trifuoroactyldaunomycin Derivatives

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The spin labeled 4'-Epi-N-trifuoroacetyldaunomycin derivatives 6-7 were conveniently synthesized from daunomycin in middle yield. The key steps were the protection of compd. 5 at 9-position and nucleophilic displacement of 5 with R.COOH and DBU at room temperature.

  5. A bifunctional spin label reports the structural topology of phospholamban in magnetically-aligned bicelles.

    Science.gov (United States)

    McCaffrey, Jesse E; James, Zachary M; Svensson, Bengt; Binder, Benjamin P; Thomas, David D

    2016-01-01

    We have applied a bifunctional spin label and EPR spectroscopy to determine membrane protein structural topology in magnetically-aligned bicelles, using monomeric phospholamban (PLB) as a model system. Bicelles are a powerful tool for studying membrane proteins by NMR and EPR spectroscopies, where magnetic alignment yields topological constraints by resolving the anisotropic spectral properties of nuclear and electron spins. However, EPR bicelle studies are often hindered by the rotational mobility of monofunctional Cys-linked spin labels, which obscures their orientation relative to the protein backbone. The rigid and stereospecific TOAC label provides high orientational sensitivity but must be introduced via solid-phase peptide synthesis, precluding its use in large proteins. Here we show that a bifunctional methanethiosulfonate spin label attaches rigidly and stereospecifically to Cys residues at i and i+4 positions along PLB's transmembrane helix, thus providing orientational resolution similar to that of TOAC, while being applicable to larger membrane proteins for which synthesis is impractical. Computational modeling and comparison with NMR data shows that these EPR experiments provide accurate information about helix tilt relative to the membrane normal, thus establishing a robust method for determining structural topology in large membrane proteins with a substantial advantage in sensitivity over NMR.

  6. Membrane fluidity profiles as deduced by saturation-recovery EPR measurements of spin-lattice relaxation times of spin labels.

    Science.gov (United States)

    Mainali, Laxman; Feix, Jimmy B; Hyde, James S; Subczynski, Witold K

    2011-10-01

    There are no easily obtainable EPR spectral parameters for lipid spin labels that describe profiles of membrane fluidity. The order parameter, which is most often used as a measure of membrane fluidity, describes the amplitude of wobbling motion of alkyl chains relative to the membrane normal and does not contain explicitly time or velocity. Thus, this parameter can be considered as nondynamic. The spin-lattice relaxation rate (T(1)(-1)) obtained from saturation-recovery EPR measurements of lipid spin labels in deoxygenated samples depends primarily on the rotational correlation time of the nitroxide moiety within the lipid bilayer. Thus, T(1)(-1) can be used as a convenient quantitative measure of membrane fluidity that reflects local membrane dynamics. T(1)(-1) profiles obtained for 1-palmitoyl-2-(n-doxylstearoyl)phosphatidylcholine (n-PC) spin labels in dimyristoylphosphatidylcholine (DMPC) membranes with and without 50 mol% cholesterol are presented in parallel with profiles of the rotational diffusion coefficient, R(⊥), obtained from simulation of EPR spectra using Freed's model. These profiles are compared with profiles of the order parameter obtained directly from EPR spectra and with profiles of the order parameter obtained from simulation of EPR spectra. It is shown that T(1)(-1) and R(⊥) profiles reveal changes in membrane fluidity that depend on the motional properties of the lipid alkyl chain. We find that cholesterol has a rigidifying effect only to the depth occupied by the rigid steroid ring structure and a fluidizing effect at deeper locations. These effects cannot be differentiated by profiles of the order parameter. All profiles in this study were obtained at X-band (9.5 GHz).

  7. Solvent interactions and protein dynamics in spin-labeled T4 lysozyme.

    Science.gov (United States)

    Stoica, I

    2004-06-01

    Aspects of T4 lysozyme dynamics and solvent interaction are investigated using atomically detailed Molecular Dynamics (MD) simulations. Two spin-labeled mutants of T4 lysozyme are analyzed (T4L-N40C and T4L-K48C), which have been found from electronic paramagnetic resonance (EPR) experiments to exhibit different mobilities at the site of spin probe attachment (N- and C-terminus of helix B, respectively). Similarities and differences in solvent distribution and diffusion around the spin label, as well as around exposed and buried residues within the protein, are discussed. The purpose is to capture possible strong interactions between the spin label (ring) and solvent molecules, which may affect EPR lineshapes. The effect of backbone motions on the water density profiles is also investigated. The focus is on the domain closure associated with the T4 lysozyme hinge-bending motion, which is analyzed by Essential Dynamics (ED). The N-terminus of helix B is found to be a "hinge" residue, which explains the high degree of flexibility and motional freedom at this site.

  8. Synthesis of spin-labeled riboswitch RNAs using convertible nucleosides and DNA-catalyzed RNA ligation.

    Science.gov (United States)

    Büttner, Lea; Seikowski, Jan; Wawrzyniak, Katarzyna; Ochmann, Anne; Höbartner, Claudia

    2013-10-15

    Chemically stable nitroxide radicals that can be monitored by electron paramagnetic resonance (EPR) spectroscopy can provide information on structural and dynamic properties of functional RNA such as riboswitches. The convertible nucleoside approach is used to install 2,2,6,6-tetramethylpiperidin-1-oxyl (TEMPO) and 2,2,5,5-tetramethylpyrrolidin-1-oxyl (proxyl) labels at the exocyclic N(4)-amino group of cytidine and 2'-O-methylcytidine nucleotides in RNA. To obtain site-specifically labeled long riboswitch RNAs beyond the limit of solid-phase synthesis, we report the ligation of spin-labeled RNA using an in vitro selected deoxyribozyme as catalyst, and demonstrate the synthesis of TEMPO-labeled 53 nt SAM-III and 118 nt SAM-I riboswitch domains (SAM=S-adenosylmethionine).

  9. Alpha-synuclein association with phosphatidylglycerol probed by lipid spin labels.

    Science.gov (United States)

    Ramakrishnan, Muthu; Jensen, Poul H; Marsh, Derek

    2003-11-11

    Alpha-synuclein is a small presynaptic protein, which is linked to the development of Parkinson's disease. Alpha-synuclein partitions between cytosolic and vesicle-bound states, where membrane binding is accompanied by the formation of an amphipathic helix in the N-terminal section of the otherwise unstructured protein. The impact on alpha-synuclein of binding to vesicle-like liposomes has been studied extensively, but far less is known about the impact of alpha-synuclein on the membrane. The interactions of alpha-synuclein with phosphatidylglycerol membranes are studied here by using spin-labeled lipid species and electron spin resonance (ESR) spectroscopy to allow a detailed analysis of the effect on the membrane lipids. Membrane association of alpha-synuclein perturbs the ESR spectra of spin-labeled lipids in bilayers of phosphatidylglycerol but not of phosphatidylcholine. The interaction is inhibited at high ionic strength. The segmental motion is hindered at all positions of spin labeling in the phosphatidylglycerol sn-2 chain, while still preserving the chain flexibility gradient characteristic of fluid phospholipid membranes. Direct motional restriction of the lipid chains, resulting from penetration of the protein into the hydrophobic interior of the membrane, is not observed. Saturation occurs at a protein/lipid ratio corresponding to approximately 36 lipids/protein added. Alpha-synuclein exhibits a selectivity of interaction with different phospholipid spin labels when bound to phosphatidylglycerol membranes in the following order: stearic acid > cardiolipin > phosphatidylcholine > phosphatidylglycerol approximately phosphatidylethanolamine > phosphatidic acid approximately phosphatidylserine > N-acyl phosphatidylethanolamine > diglyceride. Accordingly, membrane-bound alpha-synuclein associates at the interfacial region of the bilayer where it may favor a local concentration of certain phospholipids.

  10. Simulation of spin label structure and its implication in molecular characterization

    Science.gov (United States)

    Fajer, Piotr; Fajer, Mikolai; Zawrotny, Michael; Yang, Wei

    2016-01-01

    Interpretation of EPR from spin labels in terms of structure and dynamics requires knowledge of label behavior. General strategies were developed for simulation of labels used in EPR of proteins. The criteria for those simulations are: (a) exhaustive sampling of rotamer space; (b) consensus of results independent of starting points; (c) inclusion of entropy. These criteria are satisfied only when the number of transitions in any dihedral angle exceeds 100 and the simulation maintains thermodynamic equilibrium. Methods such as conventional MD do not efficiently cross energetic barriers, Simulated Annealing, Monte Carlo or popular Rotamer Library methodologies are potential energy based and ignore entropy (in addition to their specific shortcomings: environment fluctuations, fixed environment or electrostatics). Simulated Scaling method, avoids above flaws by modulating the forcefields between 0 (allowing crossing energy barriers) and full potential (sampling minima). Spin label diffuses on this surface while remaining in thermodynamic equilibrium. Simulations show that: (a) single conformation is rare, often there are 2–4 populated rotamers; (b) position of the NO varies up to 16Å. These results illustrate necessity for caution when interpreting EPR signals in terms of molecular structure. For example the 10–16Å distance change in DEER should not be interpreted as a large conformational change, it can well be a flip about Cα -Cβ bond. Rigorous exploration of possible rotamer structures of a spin label is paramount in signal interpretation. We advocate use of bifunctional labels, which motion is restricted 10,000-fold and the NO position is restricted to 2–5Å. PMID:26478501

  11. Utility of susceptibility-weighted imaging and arterial spin perfusion imaging in pediatric brain arteriovenous shunting

    Energy Technology Data Exchange (ETDEWEB)

    Nabavizadeh, Seyed Ali; Edgar, J.C.; Vossough, Arastoo [University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2014-10-15

    The objectives of the study are to investigate the application of susceptibility-weighted imaging (SWI) and arterial spin labeling (ASL) imaging in the assessment of shunting and the draining veins in pediatric patients with arteriovenous shunting and compare the utility of SWI and ASL with conventional MR and digital subtraction angiography (DSA). This study is a retrospective study of 19 pediatric patients with arteriovenous shunting on brain MRI who were also evaluated with DSA. We assessed the ability of conventional MRI sequences, susceptibility magnitude images, phase-filtered SWI images, and pulsed ASL images in the detection of arteriovenous (AV) shunting, number of draining veins and drainage pathways in comparison to DSA. The mean number of detected draining veins on DSA (3.63) was significantly higher compared to SWI phase-filtered image (mean = 2.72), susceptibility magnitude image (mean = 2.92), ASL (mean = 1.76) and conventional MRI (2.47) (p < 0.05). Pairwise comparison of DSA difference scores (i.e., difference between MR modalities in the number of missed draining veins) revealed no difference between the MR modalities (p > 0.05). ASL was the only method that correctly identified superficial and deep venous drainage in all patients. Regarding detection of shunting, ASL, SWI phase-filtered, and magnitude images demonstrated shunting in 100, 83, and 84 % of patients, respectively. SWI depicts a higher number of draining vein compared to conventional MR pulse sequences. ASL is a sensitive approach in showing 100 % sensitivity in the detection of AV shunting and in the diagnosis of the pattern of venous drainage. The present findings suggest the added utility of both SWI and ASL in the assessment of AV shunting. (orig.)

  12. Ligand-induced changes in estrogen receptor conformation as measured by site-directed spin labeling.

    Science.gov (United States)

    Hurth, Kyle M; Nilges, Mark J; Carlson, Kathryn E; Tamrazi, Anobel; Belford, R Linn; Katzenellenbogen, John A

    2004-02-24

    Site-directed spin labeling (SDSL), the site-specific incorporation of nitroxide spin-labels into a protein, has allowed us to investigate ligand-induced conformational changes in the ligand-binding domain of human estrogen receptor alpha (hERalpha-LBD). EPR (electron paramagnetic resonance) spectroscopy of the nitroxide probe attached to ER produces different spectra depending upon the identity of the bound ligand; these differences are indicative of changes in the type and degree of motional character of the spin-label induced by different ligand-induced conformations of labeled ER. Visual inspection of EPR spectra, construction of B versus C cross-correlation plots, and cross-comparison of spectral pairs using a relative squared difference (RSD) calculation allowed receptor-ligand complexes to be profiled according to their conformational character. Plotting B and C parameters allowed us to evaluate the liganded receptor according to the motional characteristics of the attached spin-label, and they were particularly illustrative for the receptor labeled at position 530, which had motion between the fast and intermediate regimes. RSD analysis allowed us to directly compare the similarity or difference between two different spectra, and these comparisons produced groupings that paralleled those seen in B versus C cross-correlation plots, again relating meaningfully with the pharmacological nature of the bound ligand. RSD analysis was also particularly useful for qualifying differences seen with the receptor labeled at position 417, which had motion between the intermediate and slow motional regimes. This work demonstrates that B and C formulas from EPR line shape theory are useful for qualitative analysis of spectra with differences subtler than those that are often analyzed by EPR spectroscopists. This work also provides evidence that the ER can exist in a range of conformations, with specific conformations resulting from preferential stabilization of ER by the

  13. Site directed spin labelling and pulsed dipolar electron paramagnetic resonance (double electron-electron resonance) of force activation in muscle

    Energy Technology Data Exchange (ETDEWEB)

    Fajer, Piotr G [Institute of Molecular Biophysics, Department of Biological Science, National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL 32310 (United States)

    2005-05-11

    The recent development of site specific spin labelling and advances in pulsed electron paramagnetic resonance(EPR) have established spin labelling as a viable structural biology technique. Specific protein sites or whole domains can be selectively targeted for spin labelling by cysteine mutagenesis. The secondary structure of the proteins is determined from the trends in EPR signals of labels attached to consecutive residues. Solvent accessibility or label mobility display periodicities along the labelled polypeptide chain that are characteristic of {beta}-strands (periodicity of 2 residues) or {alpha}-helices (3.6 residues). Low-resolution 3D structure of proteins is determined from the distance restraints. Two spin labels placed within 60-70 A of each other create a local dipolar field experienced by the other spin labels. The strength of this field is related to the interspin distance, {proportional_to} r{sup -3}. The dipolar field can be measured by the broadening of the EPR lines for the short distances (8-20 A) or for the longer distances (17-70 A) by the pulsed EPR methods, double electron-electron resonance(DEER) and double quantum coherence (DQC). A brief review of the methodology and its applications to the multisubunit muscle protein troponin is presented below.

  14. Identifying structural features of fibrillar islet amyloid polypeptide using site-directed spin labeling.

    Science.gov (United States)

    Jayasinghe, Sajith A; Langen, Ralf

    2004-11-12

    Pancreatic amyloid deposits, composed primarily of the 37-residue islet amyloid polypeptide (IAPP), are a characteristic feature found in more than 90% of patients with type II diabetes. Although IAPP amyloid deposits are associated with areas of pancreatic islet beta-cell dysfunction and depletion and are thought to play a role in disease, their structure is unknown. We used electron paramagnetic resonance spectroscopy to analyze eight spin-labeled derivatives of IAPP in an effort to determine structural features of the peptide. In solution, all eight derivatives gave rise to electron paramagnetic resonance spectra with sharp lines indicative of rapid motion on the sub-nanosecond time scale. These spectra are consistent with a rapidly tumbling and highly dynamic peptide. In contrast, spectra for the fibrillar form exhibit reduced mobility and the presence of strong intermolecular spin-spin interactions. The latter implies that the peptide subunits are ordered and that the same residues from neighboring peptides are in close proximity to one another. Our data are consistent with a parallel arrangement of IAPP peptides within the amyloid fibril. Analysis of spin label mobility indicates a high degree of order throughout the peptide, although the N-terminal region is slightly less ordered. Possible similarities with respect to the domain organization and parallelism of Alzheimer's amyloid beta peptide fibrils are discussed.

  15. Arterial spin labelling reveals prolonged arterial arrival time in idiopathic Parkinson's disease

    Directory of Open Access Journals (Sweden)

    Sarah Al-Bachari

    2014-01-01

    A significant (p = 0.005 increase in whole brain averaged baseline AAT was observed in IPD participants (mean ± SD age 1532 ± 138 ms compared to controls (mean ± SD age 1335 ± 165 ms. Voxel-wise analysis revealed this to be widespread across the brain. However, there were no statistically significant differences in white matter lesion score, CBF, or CVR between patients and controls. Regional CBF, but not AAT, in the IPD group was found to correlate positively with Montreal cognitive assessment (MoCA scores. These findings provide further evidence of alterations in NVS in IPD.

  16. A triarylmethyl spin label for long-range distance measurement at physiological temperatures using T1 relaxation enhancement

    Science.gov (United States)

    Yang, Zhongyu; Bridges, Michael D.; López, Carlos J.; Rogozhnikova, Olga Yu.; Trukhin, Dmitry V.; Brooks, Evan K.; Tormyshev, Victor; Halpern, Howard J.; Hubbell, Wayne L.

    2016-08-01

    Site-directed spin labeling (SDSL) in combination with electron paramagnetic resonance (EPR) spectroscopy has become an important tool for measuring distances in proteins on the order of a few nm. For this purpose pairs of spin labels, most commonly nitroxides, are site-selectively introduced into the protein. Recent efforts to develop new spin labels are focused on tailoring the intrinsic properties of the label to either extend the upper limit of measurable distances at physiological temperature, or to provide a unique spectral lineshape so that selective pairwise distances can be measured in a protein or complex containing multiple spin label species. Triarylmethyl (TAM) radicals are the foundation for a new class of spin labels that promise to provide both capabilities. Here we report a new methanethiosulfonate derivative of a TAM radical that reacts rapidly and selectively with an engineered cysteine residue to generate a TAM containing side chain (TAM1) in high yield. With a TAM1 residue and Cu2+ bound to an engineered Cu2+ binding site, enhanced T1 relaxation of TAM should enable measurement of interspin distances up to 50 Å at physiological temperature. To achieve favorable TAM1-labeled protein concentrations without aggregation, proteins are tethered to a solid support either site-selectively using an unnatural amino acid or via native lysine residues. The methodology is general and readily extendable to complex systems, including membrane proteins.

  17. Selectively dispersed isotope labeling for protein structure determination by magic angle spinning NMR

    Energy Technology Data Exchange (ETDEWEB)

    Eddy, Matthew T. [Massachusetts Institute of Technology, Department of Chemistry (United States); Belenky, Marina [Brandeis University, Department of Chemistry (United States); Sivertsen, Astrid C. [Massachusetts Institute of Technology, Francis Bitter Magnet Laboratory (United States); Griffin, Robert G. [Massachusetts Institute of Technology, Department of Chemistry (United States); Herzfeld, Judith, E-mail: herzfeld@brandeis.edu [Brandeis University, Department of Chemistry (United States)

    2013-10-15

    The power of nuclear magnetic resonance spectroscopy derives from its site-specific access to chemical, structural and dynamic information. However, the corresponding multiplicity of interactions can be difficult to tease apart. Complimentary approaches involve spectral editing on the one hand and selective isotope substitution on the other. Here we present a new 'redox' approach to the latter: acetate is chosen as the sole carbon source for the extreme oxidation numbers of its two carbons. Consistent with conventional anabolic pathways for the amino acids, [1-{sup 13}C] acetate does not label {alpha} carbons, labels other aliphatic carbons and the aromatic carbons very selectively, and labels the carboxyl carbons heavily. The benefits of this labeling scheme are exemplified by magic angle spinning spectra of microcrystalline immunoglobulin binding protein G (GB1): the elimination of most J-couplings and one- and two-bond dipolar couplings provides narrow signals and long-range, intra- and inter-residue, recoupling essential for distance constraints. Inverse redox labeling, from [2-{sup 13}C] acetate, is also expected to be useful: although it retains one-bond couplings in the sidechains, the removal of CA-CO coupling in the backbone should improve the resolution of NCACX spectra.

  18. Effects of oxygen on EPR spectra of nitroxide spin-label probes of model membranes

    Science.gov (United States)

    Popp, Carol A.; Hyde, James S.

    The use of a methylpentene polymer, TPX, for construction of sample containers that allow easy equilibration of electron paramagnetic resonance samples with nitrogen is described. The effects of oxygen-dependent shortening of the electron spin relaxation times of nitroxide spin labels were studied in dispersions of dimyristoylphosphatidylcholine (DMPC) and dipalmitoylphosphatidylchohne (DPPC). First-harmonic, in-phase, absorption spectra of deoxygenated samples of 2-(14-carboxytetradecyl)-2-ethyl-4,4-dimethyl-3-oxazolidinyloxyl (16SASL) in DMPC display decreased linewidths and increased peak-to-peak heigths and resolution of 13C splittings. Continuous-wave (cw) saturation studies of 16SASL/DMPC and both lipid- and aqueous-phase components of 2,2,6,6-tetramethyl-piperidinooxyl (Tempo) partitioned into DPPC show that the rf field at which the signal intensity is maximized decreases when aerated samples are equilibrated with nitrogen. Second-harmonic, out-of-phase, absorption (saturation transfer) spectra of deoxygenated samples of 16SASUDMPC at -22°C and 2-(3-carboxypropyl)-4,4-dimethyl-2-tridecyl-3-oxazolidinyloxyl (5SASL) in DPPC at 35°C display increased signal intensity and lineshape changes. Electron-electron double resonance (ELDOR) spectra display much greater ELDOR reduction in signal intensity when a deoxygenated sample of 16SASL/DMPC is used. Our results indicate that the routine use of deoxygenated samples in biologically relevant studies using spin-label probes should be considered.

  19. A combined EPR and MD simulation study of a nitroxyl spin label with restricted internal mobility sensitive to protein dynamics

    Science.gov (United States)

    Oganesyan, Vasily S.; Chami, Fatima; White, Gaye F.; Thomson, Andrew J.

    2017-01-01

    EPR studies combined with fully atomistic Molecular Dynamics (MD) simulations and an MD-EPR simulation method provide evidence for intrinsic low rotameric mobility of a nitroxyl spin label, Rn, compared to the more widely employed label MTSL (R1). Both experimental and modelling results using two structurally different sites of attachment to Myoglobin show that the EPR spectra of Rn are more sensitive to the local protein environment than that of MTSL. This study reveals the potential of using the Rn spin label as a reporter of protein motions.

  20. Dynamic molecular structure of DPPC-DLPC-cholesterol ternary lipid system by spin-label electron spin resonance.

    Science.gov (United States)

    Chiang, Yun-Wei; Shimoyama, Yuhei; Feigenson, Gerald W; Freed, Jack H

    2004-10-01

    The hydrated ternary lamellar lipid mixture of dipalmitoyl-PC/dilauroyl-PC/cholesterol (DPPC/DLPC/Chol) has been studied by electron spin resonance (ESR) to reveal the dynamic structure on a molecular level of the different phases that exist and coexist over virtually the full range of composition. The spectra for more than 100 different compositions at room temperature were analyzed by nonlinear least-squares fitting to provide the rotational diffusion rates and order parameters of the end-chain labeled phospholipid 16-PC. The ESR spectra exhibit substantial variation as a function of composition, even though the respective phases generally differ rather modestly from each other. The Lalpha and Lbeta phases are clearly distinguished, with the former exhibiting substantially lower ordering and greater motional rates, whereas the well-defined Lo phase exhibits the greatest ordering and relatively fast motional rates. Typically, smaller variations occur within a given phase. The ESR spectral analysis also yields phase boundaries and coexistence regions which are found to be consistent with previous results from fluorescence methods, although new features are found. Phase coexistence regions were in some cases confirmed by observing the existence of isosbestic points in the absorption mode ESR spectra from the phases. The dynamic structural properties of the DPPC-rich Lbeta and DLPC-rich Lalpha phases, within their two-phase coexistence region do not change with composition along a tie-line, but the ratio of the two phases follows the lever rule in accordance with thermodynamic principles. The analysis shows that 16-PC spin-label partitions nearly equally between the Lalpha and Lbeta phases, making it a useful probe for studying such coexisting phases. Extensive study of two-phase coexistence regions requires the determination of tie-lines, which were approximated in this study. However, a method is suggested to accurately determine the tie-lines by ESR.

  1. Using polarized muons as ultrasensitive spin labels in free radical chemistry.

    Science.gov (United States)

    McKenzie, Iain; Roduner, Emil

    2009-08-01

    In a chemical sense, the positive muon is a light proton. It is obtained at the ports of accelerators in beams with a spin polarization of 100%, which makes it a highly sensitive probe of matter. The muonium atom is a light hydrogen isotope, nine times lighter than H, with a muon as its nucleus. It reacts the same way as H, and by addition to double bonds it is implemented in free radicals in which the muon serves as a fully polarized spin label. It is reviewed here how the muon can be used to obtain information about muonium and radical reaction rates, radical structure, dynamics, and local environments. It can even tell us what a fragrance molecule does in a shampoo.

  2. Site-Directed Spin-Labeling of Nucleic Acids by Click Chemistry. Detection of Abasic Sites in Duplex DNA by EPR Spectroscopy

    DEFF Research Database (Denmark)

    Sigurdsson, Snorri; Vogel, Stefan; Shelke, Sandip

    2010-01-01

    This paper describes a spin label that can detect and identify local structural deformations in duplex DNA, in particular abasic sites. The spin label was incorporated into DNA by a new postsynthetic approach using click-chemistry on a solid support, which simplified both the synthesis and purifi......This paper describes a spin label that can detect and identify local structural deformations in duplex DNA, in particular abasic sites. The spin label was incorporated into DNA by a new postsynthetic approach using click-chemistry on a solid support, which simplified both the synthesis...... with T was consistent with the spin label displacing the T from the duplex. Addition of mercury(II) to this mispair resulted in a substantial increase in the motion of the spin label, consistent with formation of a metallopair between the T and the spinlabeled base that results in movement of the spin...... label out of the duplex and toward the solution. Thus, reposition of the spin label, when acting as a mercury(II)-controlled mechanical lever, can be readily detected by EPR spectroscopy. The ease of incorporation and properties of the new spin label make it attractive for EPR studies of nucleic acids...

  3. Saturation recovery EPR and ELDOR at W-band for spin labels

    Science.gov (United States)

    Froncisz, Wojciech; Camenisch, Theodore G.; Ratke, Joseph J.; Anderson, James R.; Subczynski, Witold K.; Strangeway, Robert A.; Sidabras, Jason W.; Hyde, James S.

    2008-08-01

    A reference arm W-band (94 GHz) microwave bridge with two sample-irradiation arms for saturation recovery (SR) EPR and ELDOR experiments is described. Frequencies in each arm are derived from 2 GHz synthesizers that have a common time-base and are translated to 94 GHz in steps of 33 and 59 GHz. Intended applications are to nitroxide radical spin labels and spin probes in the liquid phase. An enabling technology is the use of a W-band loop-gap resonator (LGR) [J.W. Sidabras, R.R. Mett, W. Froncisz, T.G. Camenisch, J.R. Anderson, J.S. Hyde, Multipurpose EPR loop-gap resonator and cylindrical TE 011 cavity for aqueous samples at 94 GHz, Rev. Sci. Instrum. 78 (2007) 034701]. The high efficiency parameter (8.2 GW -1/2 with sample) permits the saturating pump pulse level to be just 5 mW or less. Applications of SR EPR and ELDOR to the hydrophilic spin labels 3-carbamoyl-2,2,5,5-tetra-methyl-3-pyrroline-1-yloxyl (CTPO) and 2,2,6,6,-tetramethyl-4-piperidone-1-oxyl (TEMPONE) are described in detail. In the SR ELDOR experiment, nitrogen nuclear relaxation as well as Heisenberg exchange transfer saturation from pumped to observed hyperfine transitions. SR ELDOR was found to be an essential method for measurements of saturation transfer rates for small molecules such as TEMPONE. Free induction decay (FID) signals for small nitroxides at W-band are also reported. Results are compared with multifrequency measurements of T1e previously reported for these molecules in the range of 2-35 GHz [J.S. Hyde, J.-J. Yin, W.K. Subczynski, T.G. Camenisch, J.J. Ratke, W. Froncisz, Spin label EPR T 1 values using saturation recovery from 2 to 35 GHz. J. Phys. Chem. B 108 (2004) 9524-9529]. The values of T1e decrease at 94 GHz relative to values at 35 GHz.

  4. mtsslSuite: In silico spin labelling, trilateration and distance-constrained rigid body docking in PyMOL

    Science.gov (United States)

    Hagelueken, Gregor; Abdullin, Dinar; Ward, Richard; Schiemann, Olav

    2013-10-01

    Nanometer distance measurements based on electron paramagnetic resonance methods in combination with site-directed spin labelling are powerful tools for the structural analysis of macromolecules. The software package mtsslSuite provides scientists with a set of tools for the translation of experimental distance distributions into structural information. The package is based on the previously published mtsslWizard software for in silico spin labelling. The mtsslSuite includes a new version of MtsslWizard that has improved performance and now includes additional types of spin labels. Moreover, it contains applications for the trilateration of paramagnetic centres in biomolecules and for rigid-body docking of subdomains of macromolecular complexes. The mtsslSuite is tested on a number of challenging test cases and its strengths and weaknesses are evaluated.

  5. EPR Distance Measurements in Native Proteins with Genetically Encoded Spin Labels.

    Science.gov (United States)

    Schmidt, Moritz J; Fedoseev, Artem; Bücker, Dennis; Borbas, Julia; Peter, Christine; Drescher, Malte; Summerer, Daniel

    2015-12-18

    The genetic encoding of nitroxide amino acids in combination with electron paramagnetic resonance (EPR) distance measurements enables precise structural studies of native proteins, i.e. without the need for mutations to create unique reactive sites for chemical labeling and thus with minimal structural perturbation. We here report on in vitro DEER measurements in native E. coli thioredoxin (TRX) that establish the nitroxide amino acid SLK-1 as a spectroscopic probe that reports distances and conformational flexibilities in the enzyme with nonmutated catalytic centers that are not accessible by the use of the traditional methanethiosulfonate spin label (MTSSL). We generated a rotamer library for SLK-1 that in combination with molecular dynamics (MD) simulation enables predictions of distance distributions between two SLK-1 labels incorporated into a target protein. Toward a routine use of SLK-1 for EPR distance measurements in proteins and the advancement of the approach to intracellular environments, we study the stability of SLK-1 in E. coli cultures and lysates and establish guidelines for protein expression and purification that offer maximal nitroxide stability. These advancements and insights provide new perspectives for facile structural studies of native, endogenous proteins by EPR distance measurements.

  6. Comparison of the active sites of atropinesterase and some serine proteases by spin-labeling.

    Science.gov (United States)

    van der Drift, A C; Moes, G W; van der Drift, E; Rousseeuw, B A

    1985-09-24

    going from label I to label II, the relative contribution of the latter state increases at the expense of that of the former. This is ascribed to an equilibrium between a relatively free state of the aromatic cores and a firmly bound position in the specificity pocket of these proteases. The apparently more rigid embedding of the spin-labels in the enzyme structure of AtrE suggests that the size of the nonpolar binding pocket in the active center region of this esterase allows a deeper penetration of the aromatic portions of the labels than is possible for the specificity pocket of Chymo or Sub.

  7. Genetic Incorporation of the Unnatural Amino Acid p-Acetyl Phenylalanine into Proteins for Site-Directed Spin Labeling

    Science.gov (United States)

    Evans, Eric G.B.; Millhauser, Glenn L.

    2016-01-01

    Site-directed spin labeling (SDSL) is a powerful tool for the characterization of protein structure and dynamics; however, its application in many systems is hampered by the reliance on unique and benign cysteine substitutions for the site-specific attachment of the spin label. An elegant solution to this problem involves the use of genetically encoded unnatural amino acids (UAAs) containing reactive functional groups that are chemically orthogonal to those of the 20 amino acids found naturally in proteins. These unique functional groups can then be selectively reacted with an appropriately functionalized spin probe. In this chapter, we detail the genetic incorporation of the ketone-bearing amino acid p-acetyl phenylalanine (pAcPhe) into recombinant proteins expressed in E. coli. Incorporation of pAcPhe is followed by chemoselective reaction of the ketone side chain with a hydroxylamine-functionalized nitroxide to afford the spin-labeled side chain “K1,” and we present two protocols for successful K1 labeling of proteins bearing site-specific pAcPhe. We outline the basic requirements for pAcPhe incorporation and labeling, with an emphasis on practical aspects that must be considered by the researcher if high yields of UAA incorporation and efficient labeling reactions are to be achieved. To this end, we highlight recent advances that have led to increased yields of pAcPhe incorporation, and discuss the use of aniline-based catalysts allowing for facile conjugation of the hydroxylamine spin label under mild reaction conditions. To illustrate the utility of K1 labeling in proteins where traditional cysteine-based SDSL methods are problematic, we site-specifically K1 label the cellular prion protein at two positions in the C-terminal domain and determine the interspin distance using double electron–electron resonance EPR. Recent advances in UAA incorporation and ketone-based bioconjugation, in combination with the commercial availability of all requisite

  8. Genetic Incorporation of the Unnatural Amino Acid p-Acetyl Phenylalanine into Proteins for Site-Directed Spin Labeling.

    Science.gov (United States)

    Evans, Eric G B; Millhauser, Glenn L

    2015-01-01

    Site-directed spin labeling (SDSL) is a powerful tool for the characterization of protein structure and dynamics; however, its application in many systems is hampered by the reliance on unique and benign cysteine substitutions for the site-specific attachment of the spin label. An elegant solution to this problem involves the use of genetically encoded unnatural amino acids (UAAs) containing reactive functional groups that are chemically orthogonal to those of the 20 amino acids found naturally in proteins. These unique functional groups can then be selectively reacted with an appropriately functionalized spin probe. In this chapter, we detail the genetic incorporation of the ketone-bearing amino acid p-acetyl phenylalanine (pAcPhe) into recombinant proteins expressed in E. coli. Incorporation of pAcPhe is followed by chemoselective reaction of the ketone side chain with a hydroxylamine-functionalized nitroxide to afford the spin-labeled side chain "K1," and we present two protocols for successful K1 labeling of proteins bearing site-specific pAcPhe. We outline the basic requirements for pAcPhe incorporation and labeling, with an emphasis on practical aspects that must be considered by the researcher if high yields of UAA incorporation and efficient labeling reactions are to be achieved. To this end, we highlight recent advances that have led to increased yields of pAcPhe incorporation, and discuss the use of aniline-based catalysts allowing for facile conjugation of the hydroxylamine spin label under mild reaction conditions. To illustrate the utility of K1 labeling in proteins where traditional cysteine-based SDSL methods are problematic, we site-specifically K1 label the cellular prion protein at two positions in the C-terminal domain and determine the interspin distance using double electron-electron resonance EPR. Recent advances in UAA incorporation and ketone-based bioconjugation, in combination with the commercial availability of all requisite reagents

  9. Site-specific insertion of nitroxide-spin labels into DNA probes by click chemistry for structural analyses by ELDOR spectroscopy.

    Science.gov (United States)

    Flaender, M; Sicoli, G; Fontecave, Th; Mathis, G; Saint-Pierre, C; Boulard, Y; Gambarelli, S; Gasparutto, D

    2008-01-01

    A new approach is described for the insertion of nitroxide spin-labels at specific positions within DNA oligomers. The latter bioconjugaison strategy is based on a click chemistry 1,3-dipolar cycloaddition between a spin-labeling reagent, namely the 4-azido-TEMPO, and alkyne modified uridine-containing oligonucleotides. This highly efficient labeling method was applied for site-specific incorporation of two TEMPO units within a set of double-stranded DNA constructs. Then the determination of the inter-nitroxide distances was achieved by using a four-pulses DEER technique that successfully validates the new site-directed spin labeling strategy.

  10. Robust Optimization-Based Coronary Artery Labeling From X-Ray Angiograms.

    Science.gov (United States)

    Liu, Xinglong; Hou, Fei; Qin, Hong; Hao, Aimin

    2016-11-01

    In this paper, we present an efficient robust labeling method for coronary arteries from X-ray angiograms based on energy optimization. The fundamental goal of this research is to facilitate the analysis and diagnosis of interventional surgery in the most efficient way, and such effort could also improve the performance during doctor training, and surgery simulation and planning. Compared to the prior state-of-the-art, our method is much more robust to resist noises and is tolerant to even incomplete data because of the "built-in" nature of global optimization. We start with a fully parallelized algorithm based on Hessian matrix to extract the tubular structure from the X-ray angiograms as vessel candidates. Then, instead of using the candidates directly, we use the grow cut (Vezhnevets and V. Konouchine, Growcut: Interactive multi-label N-D image segmentation by cellular automata, in Proc. of Graphicon, 2005, pp. 150-156.) method, which is similar to graph cut (Boykov et al. , Fast approximate energy minimization via graph cuts, IEEE Trans. Pattern Anal. Mach. Intell. , vol. 23, no. 11, pp. 1222-1239, Nov. 2001.)but with better performance to extract the precise vessel structure from the images. Next, we use the fast marching method with second derivatives and cross neighbors to extract the accurate skeleton segments. After that, we propose an efficient method based on iterative closest point (Z. Zhang, Iterative point matching for registration of free-form curves and surfaces, Int J. Comput. Vis., vol. 13, no. 2, pp. 119-152, 1994.) to organize the skeleton segments by treating the continuity and similarity as extra constraints. Finally, we formulate the vessel labeling problem as an energy optimization problem and solve it using belief propagation. We also demonstrate several typical applications including flow velocity estimation, heart beat estimation, and vessel diameter estimation to show its practical uses in clinical diagnosis and treatment. Our

  11. Association of spin-labeled lipids with beta-barrel proteins from the outer membrane of Escherichia coli.

    Science.gov (United States)

    Ramakrishnan, Muthu; Pocanschi, Cosmin L; Kleinschmidt, Jörg H; Marsh, Derek

    2004-09-21

    The interaction of spin-labeled lipids with beta-barrel transmembrane proteins has been studied by the electron spin resonance (ESR) methods developed for alpha-helical integral proteins. The outer membrane protein OmpA and the ferrichrome-iron receptor FhuA from the outer membrane of Escherichia coli were reconstituted in bilayers of dimyristoylphosphatidylglycerol. The ESR spectra from phosphatidylglycerol spin labeled on the 14-C atom of the sn-2 chain contain a second component from motionally restricted lipids contacting the intramembranous surface of the beta-barrel, in addition to that from the fluid bilayer lipids. The stoichiometry of motionally restricted lipids, 11 and 32 lipids/monomer for OmpA and FhuA, respectively, is constant irrespective of the total lipid/protein ratio. It is proportional to the number of transmembrane beta-strands, eight for OmpA and 22 for FhuA, and correlates reasonably well with the intramembranous perimeter of the protein. Spin-labeled lipids with different polar headgroups display a differential selectivity of interaction with the two proteins. The more pronounced pattern of lipid selectivity for FhuA than for OmpA correlates with the preponderance of positively charged residues facing the lipids in the extensions of the beta-sheet and shorter interconnecting loops on the extracellular side of FhuA.

  12. Phospholipid bilayer relaxation dynamics as revealed by the pulsed electron-electron double resonance of spin labels

    Science.gov (United States)

    Syryamina, V. N.; Dzuba, S. A.

    2012-10-01

    Electron paramagnetic resonance (EPR) spectroscopy in the form of pulsed electron-electron double resonance (ELDOR) was applied to 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) phospholipid bilayers containing lipids that were spin-labeled at different carbon positions along the lipid acyl chain. Pulsed ELDOR detects motionally induced spin flips of nitrogen nuclei in the nitroxide spin labels, which manifests itself as magnetization transfer (MT) in the nitroxide EPR spectrum. The MT effect was observed over a wide temperature range (100-225 K) on a microsecond time scale. In line with a previous study on molecular glasses [N. P. Isaev and S. A. Dzuba, J. Chem. Phys. 135, 094508 (2011), 10.1063/1.3633241], the motions that induce MT effect were suggested to have the same nature as those in dielectric secondary (β) Johari-Goldstein fast relaxation. The results were compared with literature dielectric relaxation data for POPC bilayers, revealing some common features. Molecular motions resulting in MT are faster for deeper spin labels in the membrane interior. The addition of cholesterol to the bilayer suppresses the lipid motions near the steroid nucleus and accelerates the lipid motions beyond the steroid nucleus, in the bilayer interior. This finding was attributed to the lipid acyl chains being more ordered near the steroid nucleus and less ordered in the bilayer interior. The motions are absent in dry lipids, indicating that the motions are determined by intermolecular interactions in the bilayer.

  13. Communication: Orientational self-ordering of spin-labeled cholesterol analogs in lipid bilayers in diluted conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kardash, Maria E.; Dzuba, Sergei A., E-mail: dzuba@kinetics.nsc.ru [Voevodsky Institute of Chemical Kinetics and Combustion, 630090 Novosibirsk, Russia, and Novosibirsk State University, 630090 Novosibirsk (Russian Federation)

    2014-12-07

    Lipid-cholesterol interactions are responsible for different properties of biological membranes including those determining formation in the membrane of spatial inhomogeneities (lipid rafts). To get new information on these interactions, electron spin echo (ESE) spectroscopy, which is a pulsed version of electron paramagnetic resonance (EPR), was applied to study 3β-doxyl-5α-cholestane (DCh), a spin-labeled analog of cholesterol, in phospholipid bilayer consisted of equimolecular mixture of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine and 1,2-dioleoyl-sn-glycero-3-phosphocholine. DCh concentration in the bilayer was between 0.1 mol.% and 4 mol.%. For comparison, a reference system containing a spin-labeled 5-doxyl-stearic acid (5-DSA) instead of DCh was studied as well. The effects of “instantaneous diffusion” in ESE decay and in echo-detected (ED) EPR spectra were explored for both systems. The reference system showed good agreement with the theoretical prediction for the model of spin labels of randomly distributed orientations, but the DCh system demonstrated remarkably smaller effects. The results were explained by assuming that neighboring DCh molecules are oriented in a correlative way. However, this correlation does not imply the formation of clusters of cholesterol molecules, because conventional continuous wave EPR spectra did not show the typical broadening due to aggregation of spin labels and the observed ESE decay was not faster than in the reference system. So the obtained data evidence that cholesterol molecules at low concentrations in biological membranes can interact via large distances of several nanometers which results in their orientational self-ordering.

  14. Spin labeling and Double Electron-Electron Resonance (DEER) to Deconstruct Conformational Ensembles of HIV Protease

    Science.gov (United States)

    Casey, Thomas M.; Fanucci, Gail E.

    2016-01-01

    An understanding of macromolecular conformational equilibrium in biological systems is oftentimes essential to understand function, dysfunction, and disease. For the past few years, our lab has been utilizing site-directed spin labeling (SDSL), coupled with electron paramagnetic resonance (EPR) spectroscopy, to characterize the conformational ensemble and ligand-induced conformational shifts of HIV-1 protease (HIV-1PR). The biomedical importance of characterizing the fractional occupancy of states within the conformational ensemble critically impacts our hypothesis of a conformational selection mechanism of drug-resistance evolution in HIV-1PR. The purpose of the following chapter is to give a timeline perspective of our SDSL EPR approach to characterizing conformational sampling of HIV-1PR. We provide detailed instructions for the procedure utilized in analyzing distance profiles for HIV-1PR obtained from pulsed electron–electron double resonance (PELDOR). Specifically, we employ a version of PELDOR known as double electron–electron resonance (DEER). Data are processed with the software package “DeerAnalysis” (http://www.epr.ethz.ch/software), which implements Tikhonov regularization (TKR), to generate a distance profile from electron spin-echo amplitude modulations. We assign meaning to resultant distance profiles based upon a conformational sampling model, which is described herein. The TKR distance profiles are reconstructed with a linear combination of Gaussian functions, which is then statistically analyzed. In general, DEER has proven powerful for observing structural ensembles in proteins and, more recently, nucleic acids. Our goal is to present our advances in order to aid readers in similar applications. PMID:26477251

  15. Site directed spin labeling studies of Escherichia coli dihydroorotate dehydrogenase N-terminal extension

    Energy Technology Data Exchange (ETDEWEB)

    Couto, Sheila G. [Instituto de Fisica de Sao Carlos, Universidade de Sao Paulo, Av. Trabalhador Sao-carlense 400, C.P. 369, 13560-970, Sao Carlos, SP (Brazil); Grupo de Biofisica e Fisica Aplicada a Medicina, Instituto de Fisica, Universidade Federal de Goias, Campus Samambaia, C.P. 131, 74001-970, Goiania, GO (Brazil); Cristina Nonato, M. [Laboratorio de Cristalografia de Proteinas, Faculdade de Ciencias Farmaceuticas de Ribeirao Preto, Universidade de Sao Paulo, Av. do Cafe S/N, 14040-903, Ribeirao Preto, SP (Brazil); Costa-Filho, Antonio J., E-mail: ajcosta@ffclrp.usp.br [Instituto de Fisica de Sao Carlos, Universidade de Sao Paulo, Av. Trabalhador Sao-carlense 400, C.P. 369, 13560-970, Sao Carlos, SP (Brazil); Departamento de Fisica, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Av. Bandeirantes 3900, 14040-901, Ribeirao Preto, SP (Brazil)

    2011-10-28

    Highlights: Black-Right-Pointing-Pointer EcDHODH is a membrane-associated enzyme and a promising target for drug design. Black-Right-Pointing-Pointer Enzyme's N-terminal extension is responsible for membrane association. Black-Right-Pointing-Pointer N-terminal works as a molecular lid regulating access to the protein interior. -- Abstract: Dihydroorotate dehydrogenases (DHODHs) are enzymes that catalyze the fourth step of the de novo synthesis of pyrimidine nucleotides. In this reaction, DHODH converts dihydroorotate to orotate, using a flavine mononucleotide as a cofactor. Since the synthesis of nucleotides has different pathways in mammals as compared to parasites, DHODH has gained much attention as a promising target for drug design. Escherichia coli DHODH (EcDHODH) is a family 2 DHODH that interacts with cell membranes in order to promote catalysis. The membrane association is supposedly made via an extension found in the enzyme's N-terminal. In the present work, we used site directed spin labeling (SDSL) to specifically place a magnetic probe at positions 2, 5, 19, and 21 within the N-terminal and thus monitor, by using Electron Spin Resonance (ESR), dynamics and structural changes in this region in the presence of a membrane model system. Overall, our ESR spectra show that the N-terminal indeed binds to membranes and that it experiences a somewhat high flexibility that could be related to the role of this region as a molecular lid controlling the entrance of the enzyme's active site and thus allowing the enzyme to give access to quinones that are dispersed in the membrane and that are necessary for the catalysis.

  16. Librational motion of spin-labeled lipids in high-cholesterol containing membranes from echo-detected EPR spectra.

    Science.gov (United States)

    Erilov, Denis A; Bartucci, Rosa; Guzzi, Rita; Marsh, Derek; Dzuba, Sergei A; Sportelli, Luigi

    2004-12-01

    Two-pulse, echo-detected (ED) electron paramagnetic resonance (EPR) spectroscopy was used to study the librational motions of spin-labeled lipids in membranes of dipalmitoylphosphatidylcholine + 50 mol % cholesterol. The temperature dependence, over the range 77-240 K, and the dependence on position of spin-labeling in the sn-2 chain (n=5, 7, 10, 12, and 14) of the phospholipid, were characterized in detail. The experimental ED-spectra were corrected for instantaneous spin diffusion arising from static spin-spin interactions, by using spectra recorded at 77 K, where motional contributions are negligible. Simulations according to a model of rapid, small-amplitude librations about an axis whose direction is randomly distributed are able to describe the experimental spectra. Calibrations, in terms of the amplitude-correlation time product, alpha2tauc, were constructed for diagnostic spectral line-height ratios at different echo delay times, and for relaxation spectra obtained from the ratio of ED-spectra recorded at two different echo delays. The librational amplitude, alpha2, was determined for a spin label at the 14-C position of the lipid chain from the partially motionally averaged hyperfine splitting in the conventional EPR spectra. The librational correlation time, tauc, which is deduced from combination of the conventional and ED-EPR results, lies in the subnanosecond regime and depends only weakly on temperature. The temperature dependence of the ED-EPR spectra arises mainly from an increase in librational amplitude with increasing temperature, and position down the lipid chain. A gradual transition takes place at higher temperatures, from a situation in which segmental torsional librations are cumulative, i.e., the contributions of the individual segments add up progressively upon going down the chain, to one of concerted motion only weakly dependent on chain position. Such librational motions are important for glass-like states and are generally relevant to

  17. Long-term MRI tracking of dual-labeled adipose-derived stem cells homing into mouse carotid artery injury

    Directory of Open Access Journals (Sweden)

    Qin JB

    2012-10-01

    Full Text Available Jin-Bao Qin,1,5,* Kang-An Li,2,* Xiang-Xiang Li,1,5 Qing-Song Xie,3 Jia-Ying Lin,4 Kai-Chuang Ye,1,5 Mi-Er Jiang,1,5 Gui-Xiang Zhang,2 Xin-Wu Lu1,51Department of Vascular Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University, School of Medicine, 2Department of Radiology, Shanghai First People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 3Department of Neurosurgery, Cixi Municipal People's Hospital, Zhejiang Province, China; 4Clinic for Gynecology, Charite-Universitatsmedizin Berlin, Berlin, Germany; 5Vascular Center, Shanghai Jiao Tong University, Shanghai, China*These two authors contributed equally to this workBackground: Stem cell therapy has shown great promise for regenerative repair of injured or diseased tissues. Adipose-derived stem cells (ADSCs have become increasingly attractive candidates for cellular therapy. Magnetic resonance imaging has been proven to be effective in tracking magnetic-labeled cells and evaluating their clinical relevance after cell transplantation. This study investigated the feasibility of imaging green fluorescent protein-expressing ADSCs (GFP-ADSCs labeled with superparamagnetic iron oxide particles, and tracked them in vivo with noninvasive magnetic resonance imaging after cell transplantation in a model of mouse carotid artery injury.Methods: GFP-ADSCs were isolated from the adipose tissues of GFP mice and labeled with superparamagnetic iron oxide particles. Intracellular stability, proliferation, and viability of the labeled cells were evaluated in vitro. Next, the cells were transplanted into a mouse carotid artery injury model. Clinical 3 T magnetic resonance imaging was performed immediately before and 1, 3, 7, 14, 21, and 30 days after cell transplantation. Prussian blue staining and histological analysis were performed 7 and 30 days after transplantation.Results: GFP-ADSCs were found to be efficiently labeled with superparamagnetic iron oxide

  18. Use of spin labels to evaluate effects of cold shock and osmolality on sperm

    Energy Technology Data Exchange (ETDEWEB)

    Hammerstedt, R.H.; Keith, A.D.; Snipes, W.; Amann, R.P.; Arruda, D.; Griel, L.C. Jr.

    1978-05-01

    Spin labels were used to evaluate the effects of butylated hydroxytoluene (BHT), rapid cooling to 0/sup 0/C and osmolality on the integrity of sperm membranes. In vitro incubation of rabbit sperm with 0.5 mM BHT prior to artificial insemination did not alter the fertilizing ability of the sperm. Sperm from 6 species were ranked in terms of susceptibility to membrane damage caused by rapid cooling to 0/sup 0/C. The integrity of bull and ram sperm membranes was destroyed by the rapid cooling; BHT protected membranes of these spermatozoa from cold-induced lysis. Boar sperm membranes were porous after rapid cooling and BHT did not prevent this membrane damage. Membranes of rabbit and rooster sperm were not damaged by rapid cooling to 0/sup 0/C. Stallion sperm could not be analyzed because their membranes were altered by addition of reagents necessary to use the technique. The responses of bull, ram and rabbit sperm membranes to hyper- and hypo-osmotic conditions were determined. Hypotonic treatment (less than 200 mOsm) resulted in a 50 percent expansion of the volume of the aqueous compartment of sperm while hypertonic (700 mOsm) conditions compressed the volume of the aqueous compartment to 25 to 30 percent of the volume measured at 300 mOsm. Bull sperm, but not rabbit or ram sperm, responded as ''perfect osmometers'' between 300 and 700 mOsm.

  19. Structure and dynamics of spin-labeled insulin entrapped in a silica matrix by the sol-gel method.

    Science.gov (United States)

    Vanea, E; Gruian, C; Rickert, C; Steinhoff, H-J; Simon, V

    2013-08-12

    The structure and conformational dynamics of insulin entrapped into a silica matrix was monitored during the sol to maturated-gel transition by electron paramagnetic resonance (EPR) spectroscopy. Insulin was successfully spin-labeled with iodoacetamide and the bifunctional nitroxide reagent HO-1944. Room temperature continuous wave (cw) EPR spectra of insulin were recorded to assess the mobility of the attached spin labels. Insulin conformation and its distribution within the silica matrix were studied using double electron-electron resonance (DEER) and low-temperature cw-EPR. A porous oxide matrix seems to form around insulin molecules with pore diameters in the order of a few nanometers. Secondary structure of the encapsulated insulin investigated by Fourier transform infrared spectroscopy proved a high structural integrity of insulin even in the dried silica matrix. The results show that silica encapsulation can be used as a powerful tool to effectively isolate and functionally preserve biomolecules during preparation, storage, and release.

  20. Comparing continuous wave progressive saturation EPR and time domain saturation recovery EPR over the entire motional range of nitroxide spin labels.

    Science.gov (United States)

    Nielsen, Robert D; Canaan, Stephane; Gladden, James A; Gelb, Michael H; Mailer, Colin; Robinson, Bruce H

    2004-07-01

    The measurement of spin-lattice relaxation rates from spin labels, such as nitroxides, in the presence and absence of spin relaxants provides information that is useful for determining biomolecular properties such as nucleic acid dynamics and the interaction of proteins with membranes. We compare X-band continuous wave (CW) and pulsed or time domain (TD) EPR methods for obtaining spin-lattice relaxation rates of spin labels across the entire range of rotational motion to which relaxation rates are sensitive. Model nitroxides and spin-labeled biological species are used to illustrate the potential complications that arise in extracting relaxation data under conditions typical to biological experiments. The effect of super hyperfine (SHF) structure is investigated for both CW and TD spectra. First and second harmonic absorption and dispersion CW spectra of the nitroxide spin label, TEMPOL, are all fit simultaneously to a model of SHF structure over a range of microwave amplitudes. The CW spectra are novel because all harmonics and microwave phases were acquired simultaneously using our homebuilt CW/TD spectrometer. The effect of the SHF structure on the pulsed free induction decay (FID) and pulsed saturation recovery spectrum is shown for both protonated and deuterated TEMPOL. We present novel pulsed saturation recovery measurements on biological molecules, including spin-lattice relaxation rates of spin-labeled proteins and spin-labeled double-stranded DNA. The impact of structure and dynamics on relaxation rates are discussed in the context of each of these examples. Collisional relaxation rates with oxygen and transition metal paramagnetic relaxants are extracted using both continuous wave and time domain methods. The extent of the errors inherent in the CW method and the advantages of pulsed methods for unambiguously measuring collisional relaxation rates are discussed. Spin-lattice relaxation rates, determined by both CW and pulsed methods, are used to determine

  1. Mobility of TOAC spin-labelled peptides binding to the Src SH3 domain studied by paramagnetic NMR

    Energy Technology Data Exchange (ETDEWEB)

    Lindfors, Hanna E. [Leiden University, Leiden Institute of Chemistry, Gorlaeus Laboratories (Netherlands); Koning, Peter E. de; Wouter Drijfhout, Jan [Leiden University Medical Centre, Department of Immunohematology and Blood Transfusion (Netherlands); Venezia, Brigida; Ubbink, Marcellus [Leiden University, Leiden Institute of Chemistry, Gorlaeus Laboratories (Netherlands)], E-mail: m.ubbink@chem.leidenuniv.nl

    2008-07-15

    Paramagnetic relaxation enhancement provides a tool for studying the dynamics as well as the structure of macromolecular complexes. The application of side-chain coupled spin-labels is limited by the mobility of the free radical. The cyclic, rigid amino acid spin-label TOAC (2,2,6,6-Tetramethylpiperidine-1-oxyl-4-amino-4-carboxylic acid), which can be incorporated straightforwardly by peptide synthesis, provides an attractive alternative. In this study, TOAC was incorporated into a peptide derived from focal adhesion kinase (FAK), and the interaction of the peptide with the Src homology 3 (SH3) domain of Src kinase was studied, using paramagnetic NMR. Placing TOAC within the binding motif of the peptide has a considerable effect on the peptide-protein binding, lowering the affinity substantially. When the TOAC is positioned just outside the binding motif, the binding constant remains nearly unaffected. Although the SH3 domain binds weakly and transiently to proline-rich peptides from FAK, the interaction is not very dynamic and the relative position of the spin-label to the protein is well-defined. It is concluded that TOAC can be used to generate reliable paramagnetic NMR restraints.

  2. Use of paramagnetic chelated metal derivatives of polysaccharides and spin-labeled polysaccharides as contrast agents in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bligh, S.W.; Harding, C.T.; Sadler, P.J.; Bulman, R.A.; Bydder, G.M.; Pennock, J.M.; Kelly, J.D.; Latham, I.A.; Marriott, J.A. (Department of Chemistry, Birkbeck College, London (England))

    1991-02-01

    Soluble and insoluble polysaccharides were derivatized with diethylenetriaminepentaacetic acid (DTPA) and/or spin-labeled with 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO). Polysaccharides derivatized with DTPA were prepared via cyanogen bromide activation, coupling to a diamine linker, and to DTPA anhydride. Spin-labeled polysaccharides were also prepared via cyanogen bromide activation. The extent of derivatization for dextran (18 kDa) was about 120 glucose units per DTPA, and for cellulose and starch about 15-30 units per DTPA. For spin-labeled polysaccharides, the average loading ranged from 1 nitroxide per 16 glucose units for starch to 181 for dextran (82 kDa). These derivatized paramagnetic polysaccharides were shown to be more effective relaxants than the small paramagnetic molecules alone. Both soluble and insoluble polysaccharide-linker-DTPA-Gd(3) complexes were effectively cleared from the body (rats) after oral administration. After intravenous administration, the biodistribution of dextran-linker-DTPA-Gd(3) complexes differed significantly from that of GdDTPA. Reduction of the nitroxide by ascorbic acid was retarded in the polysaccharide derivatives, particularly in starch derivatized with both nitroxide and linker-DTPA-Cu(2). These agents showed contrast enhancement in the gastrointestinal tract of rabbits.

  3. Application of rate equations to ELDOR and saturation recovery experiments on 14N: 15N spin-label pairs

    Science.gov (United States)

    Yin, Jun-Jie; Hyde, James S.

    Rate equations describing the time dependence of population differences of the five allowed transitions in an 14N 15N spin-label pair problem are set up. Included in the formulation are the three Heisenberg exchange rate constants and different nitrogen nuclear spin-lattice relaxation rates, electron spin-lattice relaxation rates, and populations for the 14N and 15N moieties. Using matrix algebra, stationary and time-dependent solutions are obtained in a unified theoretical framework. The calculations apply to stationary and pulse electron-electron double resonance and to saturation-recovery ESR. Particular emphasis is placed on short pulse initial excitation, where the transverse relaxation processes are sufficiently slow that only the population difference of the irradiated transition departs significantly from Boltzmann equilibrium during the excitation.

  4. Renal arterial spin labeling magnetic resonance imaging in normal adults:a study with a 3.0 T scanner%3.0T磁共振动脉自旋标记技术在正常成人肾脏检查中的应用

    Institute of Scientific and Technical Information of China (English)

    张帆; 张雪林; 杨立; 沈洁; 高伟

    2013-01-01

    目的分析单次激发快速自旋回波-流动敏感反转恢复序列(SSFSE-FAIR)与平面回波-流动敏感反转恢复序列(EPI-FAIR)所测量的健康肾脏的相对血流量值(rBFV),评价两种动脉自旋标记(ASL)序列在正常肾脏检查中的应用价值。方法前瞻性分析40例符合纳入标准的受试者的rBFV。采用3.0T磁共振扫描仪扫描。按3种方式采集图像:EPI-FAIR屏气法、SSFSE-FAIR屏气法及SSFSE-FAIR自由呼吸法。结果SSFSE-FAIR自由呼吸法可定量区分肾脏皮髓质。皮质rBFV:111.48±9.23;髓质rBFV:94.98±3.38;SSFSE-FAIR屏气法及EPI-FAIR不能定量区分肾脏皮髓质。EPI-FAIR皮髓平均rBFV为178.50±17.17,95%置信区间:167.59~189.41。结论 SSFSE-FAIR屏气法及EPI-FAIR空间分辨率低,无法区分肾脏皮髓质,可粗略评价肾脏灌注情况。SSFSE-FAIR图像空间分辨率较高,可区分肾脏皮髓质结构,可初步评判肾脏皮髓质的灌注状态。%Objective To analyze the renal relative blood flow value (rBFV) and image quality in normal adults using single-shot fast spin echo, flow sensitive invention recovery (SSFSE-FAIR) magnetic resonance (MR) sequence and echo planar imaging, and flow sensitive invention recovery (EPI-FAIR) MR sequence, and assess its value for clinical application in routine renal examination. Methods Forty volunteers (25 male and 15 female adults, aged 30 to 62 years) with normal renal function were included in this prospective study. All the subjects underwent 3.0 Tesla MR scanning using 3 MR scan modes, namely breath-holding EPI-FAIR, breath-holding SSFSE-FAIR and free breathing SSFSE-FAIR. Results SSFSE-FAIR without breath-holding was capable of differentiating the renal cortex and medulla with the corresponding rBFVs of 111.48 ± 9.23 and 94.98 ± 3.38, respectively. Breath-holding SSFSE-FAIR and EPI-FAIR failed to distinguish the borders of the renal cortex and medulla. The EPI-FAIR rBFV of mixed

  5. Solvent effect on librational dynamics of spin-labelled haemoglobin by ED- and CW-EPR.

    Science.gov (United States)

    Scarpelli, Francesco; Bartucci, Rosa; Sportelli, Luigi; Guzzi, Rita

    2011-03-01

    Two-pulse, echo-detected electron paramagnetic resonance (ED-EPR) spectra and continuous-wave EPR (CW-EPR) spectra were used to investigate the solvent effect on the librational motion of human haemoglobin spin-labelled on cysteine β93 with the nitroxide derivative of maleimide, 6-MSL. Protein samples fully hydrated in phosphate buffer solution (PBS), in a 60% v/v glycerol/water mixture and in the lyophilized form were measured at cryogenic temperature in the frozen state. The protein librational motion was characterized by the amplitude-correlation time product, τ(c), deduced from the ED-EPR spectra. The librational amplitude, τ(c), was determined independently, from the motionally averaged hyperfine splitting in the CW-EPR spectra, and the librational correlation time, τ(c), was derived from the combination of the pulsed and conventional EPR data. Rapid librational motion of small amplitude was detected in all samples. In each case, the librational dynamics was restricted up to 180 K, beyond which it increased steeply for the hydrated protein in PBS and in the presence of glycerol. In contrast, in the dehydrated protein, the librational dynamics was hindered and less dependent on temperature up to ~240 K. In all samples, deviated from small values only for T > 200 K, where a rapid increase of was evident for the hydrated samples, whereas limited temperature variation was shown in the lyophilized samples. The librational correlation time was in the sub-nanosecond regime and weakly dependent on temperature. The results evidence that solvent favours protein dynamics.

  6. Design, Synthesis, EPR-Studies and Conformational Bias of Novel Spin-Labeled DCC-Analogues for the Highly Regioselective Labeling of Aliphatic and Aromatic Carboxylic Acids.

    Science.gov (United States)

    Gölz, Jan Philipp; NejatyJahromy, Yaser; Bauer, Mirko; Muhammad, Ashraf; Schnakenburg, Gregor; Grimme, Stefan; Schiemann, Olav; Menche, Dirk

    2016-07-04

    Novel types of spin-labeled N,N'-dicyclohexylcarbodiimides (DCC) are reported that bear a 2,2,6,6-tetramethylpiperidinyloxyl (TEMPO) residue on one side and different aromatic and aliphatic cyclohexyl analogues on the other side of the diimide core. These readily available novel reagents add efficiently to aliphatic and aromatic carboxylic acids, forming two possible spin-labeled amide derivatives with different radical distances of the resulting amide. The addition of aromatic DCC analogues proceeds with excellent selectivity, giving amides where the carboxylic acid is exclusively connected to the aromatic residue, while little or no selectivity was observed for the aliphatic congeners. The usefulness of these adducts in structural studies was demonstrated by EPR (electron paramagnetic resonance) measurements of biradical adducts of biphenyl-4,4'-dicarboxylic acids. These analyses also reveal high degrees of conformational bias for aromatic DCC derivatives, which further underlines the powerfulness of these novel reagents. This observation was further corroborated by quantum chemical calculations, giving a detailed understanding of the structural dynamics, while detailed information on the solid state structure of all novel reagents was obtained by X-ray structure analyses.

  7. Contrast optimization in multiphase arterial spin labeling; Otimizacao do contraste em ASL multi-fase

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Fernando F.; Paschoal, Andre M., E-mail: paiva@ifsc.usp.br [Universidade de Sao Paulo (CIERMag/USP), Sao Carlos, SP (Brazil). Instituto de Fisica; Foerster, Bernd U. [Philips Medical Systems LatAm, Sao Paulo, SP (Brazil); Tovar-Moll, Fernanda; Moll, Jorge [Instituto D' Or de Pesquisa e Ensino, Rio de Janeiro, RJ (Brazil)

    2013-08-15

    Multiphase ASL is an effective way to overcome the regional variation of the transit time that difficult the estimation of perfusion values. However, with conventional multiple phases ASL techniques, the ASL contrast at later phases is impaired due to repeated application of excitation pulses and longitudinal relaxation making it difficult to evaluate the tissue perfusion in regions where the transit time is longer. In the present study, we show an improvement of the acquisition scheme by exploring a modulation on the flip angle of the MR acquisition to keep the ASL contrast constant over multiple phases. (author)

  8. Cerebral blood flow in presymptomatic MAPT and GRN mutation carriers: A longitudinal arterial spin labeling study

    Directory of Open Access Journals (Sweden)

    Elise G.P. Dopper, PhD

    2016-01-01

    Interpretation: We demonstrated longitudinal alterations in CBF in presymptomatic FTD independent of grey matter atrophy, with the strongest decrease in individuals that developed symptoms during follow-up. Therefore, ASL could have the potential to serve as a sensitive biomarker of disease progression in the presymptomatic stage of FTD in future clinical trials.

  9. RELATIONSHIP BETWEEN EFFICENCIES OF SEGMENTAL HEPATIC ARTERY CHEMOEMBOLIZATION AND PCNA LABELING INDEX IN HCC

    Institute of Scientific and Technical Information of China (English)

    李玉亮; 邵广瑞

    2004-01-01

    Objective: To evaluate the relationship between the efficiencies of subsegmental TAE and the expression of PCNA with ABC immunohistochemical staining in HCCs. Methods: Ultrasound-guided needle biopsies were performed in 43 patients (41 men, 2 women; age range: 32~75 years, mean, 55.6 years). PCNA were examined using ABC immunohistochemical staining. Tumor scores of PCNA were assessed by counting the positive nuclei per 1,000 cells. All the cases received subsegmental TAE with iodized oil and gelatin sponge. A correlation between the expression of PCNA and the efficiencies of subsegmental TAE was sought. Normality test, rank sum test and Chi-square test were used in statistical analyses with SAS package. Results: The mean PCNA labeling index was 58±29(range, 27-100%) in 43 patients. When compared with the macroscopic and pathologic parameters, PCNA labeling index was found to be significantly related to the presence and activity of cirrhosis. PCNA labeling index did not related to patients' age, sex, HbsAg status or serum α-fetoprotein level. The PCNA labeling index corresponded to the degree of histological differentiation (Edmenderson- Steiner grading). The survival rates after subsegmental TAE were respectively 86.05%, 65.12% and 51.16% in one-, two- and three-years, and were significantly higher in the low labeling index group than that in the high labeling index group. Conclusion: The PCNA labeling index was shown to be closely related to histological characteristics and survival of the patients.

  10. Exploring Structure, Dynamics, and Topology of Nitroxide Spin-Labeled Proteins Using Continuous-Wave Electron Paramagnetic Resonance Spectroscopy.

    Science.gov (United States)

    Altenbach, Christian; López, Carlos J; Hideg, Kálmán; Hubbell, Wayne L

    2015-01-01

    Structural and dynamical characterization of proteins is of central importance in understanding the mechanisms underlying their biological functions. Site-directed spin labeling (SDSL) combined with continuous-wave electron paramagnetic resonance (CW EPR) spectroscopy has shown the capability of providing this information with site-specific resolution under physiological conditions for proteins of any degree of complexity, including those associated with membranes. This chapter introduces methods commonly employed for SDSL and describes selected CW EPR-based methods that can be applied to (1) map secondary and tertiary protein structure, (2) determine membrane protein topology, (3) measure protein backbone flexibility, and (4) reveal the existence of conformational exchange at equilibrium.

  11. Arterial Transit Time Mapping Obtained by Pulsed Continuous 3D ASL Imaging with Multiple Post-Label Delay Acquisitions: Comparative Study with PET-CBF in Patients with Chronic Occlusive Cerebrovascular Disease.

    Science.gov (United States)

    Tsujikawa, Tetsuya; Kimura, Hirohiko; Matsuda, Tsuyoshi; Fujiwara, Yasuhiro; Isozaki, Makoto; Kikuta, Ken-Ichiro; Okazawa, Hidehiko

    2016-01-01

    Arterial transit time (ATT) is most crucial for measuring absolute cerebral blood flow (CBF) by arterial spin labeling (ASL), a noninvasive magnetic resonance (MR) perfusion assessment technique, in patients with chronic occlusive cerebrovascular disease. We validated ASL-CBF and ASL-ATT maps calculated by pulsed continuous ASL (pCASL) with multiple post-label delay acquisitions in patients with occlusive cerebrovascular disease. Fifteen patients underwent MR scans, including pCASL, and positron emission tomography (PET) scans with 15O-water to obtain PET-CBF. MR acquisitions with different post-label delays (1.0, 1.5, 2.0, 2.5 and 3.0 sec) were also obtained for ATT correction. The theoretical framework of 2-compartmental model (2CM) was also used for the delay compensation. ASL-CBF and ASL-ATT were calculated based on the proposed 2CM, and the effect on the CBF values and the ATT correction characteristics were discussed. Linear regression analyses were performed both on pixel-by-pixel and region-of-interest bases in the middle cerebral artery (MCA) territory. There were significant correlations between ASL-CBF and PET-CBF both for voxel values (r = 0.74 ± 0.08, slope: 0.87 ± 0.22, intercept: 6.1 ± 4.9) and for the MCA territorial comparison in both affected (R2 = 0.67, y = 0.83x + 6.3) and contralateral sides (R2 = 0.66, y = 0.74x + 6.3). ASL-ATTs in the affected side were significantly longer than those in the contralateral side (1.51 ± 0.41 sec and 1.12 ± 0.30 sec, respectively, p <0.0005). CBF measurement using pCASL with delay compensation was feasible and fairly accurate even in altered hemodynamic states.

  12. The influence of spin-labeled fluorene compounds on the assembly and toxicity of the aβ peptide.

    Directory of Open Access Journals (Sweden)

    Jitka Petrlova

    Full Text Available BACKGROUND: The deposition and oligomerization of amyloid β (Aβ peptide plays a key role in the pathogenesis of Alzheimer's disease (AD. Aβ peptide arises from cleavage of the membrane-associated domain of the amyloid precursor protein (APP by β and γ secretases. Several lines of evidence point to the soluble Aβ oligomer (AβO as the primary neurotoxic species in the etiology of AD. Recently, we have demonstrated that a class of fluorene molecules specifically disrupts the AβO species. METHODOLOGY/PRINCIPAL FINDINGS: To achieve a better understanding of the mechanism of action of this disruptive ability, we extend the application of electron paramagnetic resonance (EPR spectroscopy of site-directed spin labels in the Aβ peptide to investigate the binding and influence of fluorene compounds on AβO structure and dynamics. In addition, we have synthesized a spin-labeled fluorene (SLF containing a pyrroline nitroxide group that provides both increased cell protection against AβO toxicity and a route to directly observe the binding of the fluorene to the AβO assembly. We also evaluate the ability of fluorenes to target multiple pathological processes involved in the neurodegenerative cascade, such as their ability to block AβO toxicity, scavenge free radicals and diminish the formation of intracellular AβO species. CONCLUSIONS: Fluorene modified with pyrroline nitroxide may be especially useful in counteracting Aβ peptide toxicity, because they possess both antioxidant properties and the ability to disrupt AβO species.

  13. The subunit b dimer of the FOF1-ATP synthase: interaction with F1-ATPase as deduced by site-specific spin-labeling.

    Science.gov (United States)

    Motz, Christian; Hornung, Tassilo; Kersten, Michael; McLachlin, Derek T; Dunn, Stanley D; Wise, John G; Vogel, Pia D

    2004-11-19

    We have used site-specific spin-labeling of single cysteine mutations within a water-soluble mutant of subunit b of the ATP synthase and employed electron spin resonance (ESR) spectroscopy to obtain information about the binding interactions of the b dimer with F1-ATPase. Interaction of b2 with a delta-depleted F1 (F1-delta) was also studied. The cysteine mutations used for spin-labeling were distributed throughout the cytosolic domain of the b subunit. In addition, each position between residues 101 and 114 of b was individually mutated to cysteine. All mutants were modified with a cysteine-reactive spin label. The room temperature ESR spectra of spin-labeled b2 in the presence of F1 or F1-delta when compared with the spectra of free b2 indicate a tight binding interaction between b2 and F1. The data suggest that b2 packs tightly to F1 between residues 80 and the C terminus but that there are segments of b2 within that region where packing interactions are quite loose. Two-dimensional gel electrophoresis confirmed binding of the modified b mutants to F1-ATPase as well as to F1-delta. Subsequent addition of delta to F1-delta.b2 complex resulted in changes in the ESR spectra, indicating different binding interactions of b to F1 in the presence or absence of delta. The data also suggest that the reconstitution of the ATP synthase is not ordered with respect to these subunits. Additional spectral components observed in b preparations that were spin-labeled between amino acid position 101 and 114 are indicative of either two populations of b subunits with different packing interactions or to helical bending within this region.

  14. MtsslWizard: In Silico Spin-Labeling and Generation of Distance Distributions in PyMOL.

    Science.gov (United States)

    Hagelueken, Gregor; Ward, Richard; Naismith, James H; Schiemann, Olav

    2012-04-01

    MtsslWizard is a computer program, which operates as a plugin for the PyMOL molecular graphics system. MtsslWizard estimates distances between spin labels on proteins quickly with user-configurable options through a simple graphical interface. In default mode, the program searches for ensembles of possible MTSSL conformations that do not clash with a static model of the protein. Once conformations are assigned, distance distributions between two or more ensembles are calculated, displayed, and can be exported to other software. The program's use is evaluated in a number of challenging test cases and its strengths and weaknesses evaluated. The benefits of the program are its accuracy and simplicity. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00723-012-0314-0) contains supplementary material, which is available to authorized users.

  15. Electron paramagnetic resonance studies of magnetically aligned phospholipid bilayers utilizing a phospholipid spin label: the effect of cholesterol.

    Science.gov (United States)

    Dave, Paresh C; Nusair, Nisreen A; Inbaraj, Johnson J; Lorigan, Gary A

    2005-08-15

    X-band EPR spectroscopy has been employed to study the dynamic properties of magnetically aligned phospholipid bilayers (bicelles) utilizing a variety of phosphocholine spin labels (n-PCSL) as a function of cholesterol content. The utilization of both perpendicular and parallel aligned bicelles in EPR spectroscopy provides a more detailed structural and orientational picture of the phospholipid bilayers. The magnetically aligned EPR spectra of the bicelles and the hyperfine splitting values reveal that the addition of cholesterol increases the phase transition temperature and alignment temperature of the DMPC/DHPC bicelles. The corresponding molecular order parameter, Smol, of the DMPC/DHPC bicelles increased upon addition of cholesterol. Cholesterol also decreased the rotational motion and increased the degree of anisotropy in the interior region of the bicelles. This report reveals that the dynamic properties of DMPC/DHPC bicelles agree well with other model membrane systems and that the magnetically aligned bicelles are an excellent model membrane system.

  16. Structural characteristics of the hydrophobic patch of azurin and its interaction with p53: a site-directed spin labeling study

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Site-directed spin labeling (SDSL) is a powerful tool for monitoring protein structure, dynamics and conformational changes. In this study, the domain-specific properties of azurin and its interaction with p53 were studied using this technique. Mutations of six residues, that are located in the hydrophobic patch of azurin, were prepared and spin labeled. Spectra of the six azurin mutants in solution showed that spin labeled residues 45 and 63 are in a very restricted environment, residues 59 and 65 are in a spacious environment and have free movement, and residues 49 and 51 are located in a relatively closed pocket. Polarity experiments confirmed these results. The changes observed in the spectra of spin labeled azurin upon interaction with p53 indicate that the hydrophobic patch is involved in this interaction. Our results provide valuable insight into the topographic structure of the hydrophobic domain of azurin, as well as direct evidence of its interaction with p53 in solution via the hydrophobic patch. Cytotoxicity studies of azurin mutants showed that residues along the hydrophobic patch are important for its cytotoxicity.

  17. Do "good" food products make others look "bad"? Spin-off effects of labels for sustainable food production in the consumer perception

    NARCIS (Netherlands)

    Binnekamp, M.H.A.; Ingenbleek, P.T.M.

    2008-01-01

    Abstract Purpose ¿ The objective of this study is to examine whether sustainability labels like Fair Trade have a spin-off effect to mainstream products in the consumer perception: do consumers perceive mainstream products and brands more negatively in the presence of a product with a sustainability

  18. Imaging of injured and atherosclerotic arteries in mice using fluorescence-labeled glycoprotein VI-Fc

    Energy Technology Data Exchange (ETDEWEB)

    Bigalke, Boris, E-mail: boris.bigalke@med.uni-tuebingen.de [Medizinische Klinik III, Kardiologie und Kreislauferkrankungen, Eberhard-Karls-Universitaet Tuebingen (Germany); Division of Imaging Sciences, St Thomas' Hospital, King' s College London (United Kingdom); Pohlmeyer, Ilka; Schoenberger, Tanja [Medizinische Klinik III, Kardiologie und Kreislauferkrankungen, Eberhard-Karls-Universitaet Tuebingen (Germany); Griessinger, Christoph M. [Labor fuer Praeklinische Bildgebung und Bildgebungstechnologie der Werner-Siemens-Stiftung, Radiologische Klinik, Eberhard-Karls-Universitaet Tuebingen (Germany); Ungerer, Martin [Corimmun GmbH, Martinsried (Germany); Botnar, Rene M. [Division of Imaging Sciences, St Thomas' Hospital, King' s College London (United Kingdom); Pichler, Bernd J. [Labor fuer Praeklinische Bildgebung und Bildgebungstechnologie der Werner-Siemens-Stiftung, Radiologische Klinik, Eberhard-Karls-Universitaet Tuebingen (Germany); Gawaz, Meinrad [Medizinische Klinik III, Kardiologie und Kreislauferkrankungen, Eberhard-Karls-Universitaet Tuebingen (Germany)

    2011-08-15

    Purpose: To assess endothelial injury and repair using fluorescence-labeled glycoprotein VI (GPVI)-Fc in a murine model. Materials and methods: Three 4-week-old male ApoE-deficient (ApoE{sup -/-})-mice were fed with a 1.25% cholesterol diet over 16 weeks and compared to three wild type (WT) C57BL/6J-mice in a wire-induced vascular injury model. Another group of WT mice (n = 10) were mechanically injured by carotid ligation. Fluorescence-labeled GPVI-Fc (150 {mu}g/mouse) was administered and assessed by optical imaging 24 h after injury and compared to another group (n = 3) which was injected two days after injury and sacrificed another day later. Results: After denudation, all injured carotids of WT mice showed a higher mean fluorescence signal than the corresponding intact carotids of the same animals (48.4 {+-} 18.9 vs. 10.4 {+-} 1.0; P = 0.028). Injection of unlabeled GPVI-Fc 20 h and 3 h before injecting GPVI-Fc-FITC significantly reduced the fluorescence signal in injured carotids to 14.6 {+-} 4.6, while intact carotids showed a signal of 9.2 {+-} 1.1; P = 0.046. Ligation injury resulted with an increased GPVI-Fc-binding to injured carotids compared to intact carotids (31.53 {+-} 6.18 vs. 16.48 {+-} 5.15; P = 0.039). Three days after injury and 24 h after GPVI-Fc-FITC injection, differences between intact and injured carotids have vanished (12.51 {+-} 2.76 vs. 14.76 {+-} 1.59; P = 0.519). Conclusions: A GPVI-based plaque imaging system could help to identify vascular lesions and to take a precautionary measure as necessary.

  19. The free radical spin-trap alpha-PBN attenuates periinfarct depolarizations following permanent middle cerebral artery occlusion in rats without reducing infarct volume

    DEFF Research Database (Denmark)

    Christensen, Thomas; Bruhn, Torben; Diemer, Nils Henrik

    2003-01-01

    The effect of the free radical spin-trap alpha-phenyl-butyl-tert-nitrone (alpha-PBN) in permanent focal cerebral ischemia in rats was examined in two series of experiments. In the first, rats were subjected to permanent occlusion of the middle cerebral artery (MCAO) and treated 1 h after occlusion...

  20. The effects of general anesthetics on ESR spectra of spin labels in phosphatidylcholine vesicles containing purified Na,K-ATPase or microsomal protein

    Energy Technology Data Exchange (ETDEWEB)

    Shibuya, Makiko, E-mail: shibu@den.hokudai.ac.jp [Department of Dental Anesthesiology, Graduate School of Dental Medicine, Hokkaido University (Japan); Hiraoki, Toshifumi [Division of Applied Physics, Graduate School of Engineering, Hokkaido University (Japan); Kimura, Kunie; Fukushima, Kazuaki [Department of Dental Anesthesiology, Graduate School of Dental Medicine, Hokkaido University (Japan); Suzuki, Kuniaki [Department of Molecular Cell Pharmacology, Graduate School of Dental Medicine, Hokkaido University (Japan)

    2012-12-01

    Highlights: Black-Right-Pointing-Pointer We studied the effects of general anesthetics on liposome using ESR spectra. Black-Right-Pointing-Pointer Two spin labels, 5-DSA and 16-DSA, were located in different position in liposome. Black-Right-Pointing-Pointer Anesthetics did not change the environment around the spin labels in the liposome. Black-Right-Pointing-Pointer Anesthetics remained on the surface of the lipid bilayer of liposome. Black-Right-Pointing-Pointer Proteins in the liposome did not change the effects of anesthetics on liposome. - Abstract: We investigated the effects of general anesthetics on liposome containing spin labels, 5-doxyl stearic acid (5-DSA) and 16-doxyl stearic acid (16-DSA), and purified Na,K-ATPase or membrane protein of microsome using an electron spin resonance (ESR) spectroscopy. The spectra of 16-DSA in liposomes with both proteins showed three sharp signals compared with 5-DSA. The difference in the order parameter S value of 5-DSA and 16-DSA suggested that the nitroxide radical location of 5-DSA and 16-DSA were different in the membrane bilayer. The results were almost the same as those obtained in liposomes without proteins. The addition of sevoflurane, isoflurane, halothane, ether, ethanol and propofol increased the intensity of the signals, but the clinical concentrations of anesthetics did not significantly alter the S and {tau} values, which are indices of the fluidity of the membrane. These results suggest that anesthetics remain on the surface of the lipid bilayer and do not act on both the inside hydrophobic area and the relatively hydrophilic area near the surface. These results and others also suggest that the existence of Na,K-ATPase and microsomal proteins did not affect the environment around the spin labels in the liposome and the effects of anesthetics on liposome as a model membrane.

  1. Kinetics of rapid covalent bond formation of aniline with humic acid: ESR investigations with nitroxide spin labels

    Science.gov (United States)

    Glinka, Kevin; Matthies, Michael; Theiling, Marius; Hideg, Kalman; Steinhoff, Heinz-Jürgen

    2016-04-01

    Sulfonamide antibiotics used in livestock farming are distributed to farmland by application of slurry as fertilizer. Previous work suggests rapid covalent binding of the aniline moiety to humic acids found in soil. In the current work, kinetics of this binding were measured in X-band EPR spectroscopy by incubating Leonardite humic acid (LHA) with a paramagnetic aniline spin label (anilino-NO (2,5,5-Trimethyl-2-(3-aminophenyl)pyrrolidin-1-oxyl)). Binding was detected by a pronounced broadening of the spectral lines after incubation of LHA with anilino-NO. The time evolution of the amplitude of this feature was used for determining the reaction kinetics. Single- and double-exponential models were fitted to the data obtained for modelling one or two first-order reactions. Reaction rates of 0.16 min-1 and 0.012 min-1, were found respectively. Addition of laccase peroxidase did not change the kinetics but significantly enhanced the reacting fraction of anilino-NO. This EPR-based method provides a technically simple and effective method for following rapid binding processes of a xenobiotic substance to humic acids.

  2. QM/MD studies of the dynamics of the MTSL spin label in Aurora-A kinase protein activation loop

    CERN Document Server

    Concilio, Maria Grazia; Bayliss, Richard; Burgess, Selena

    2015-01-01

    Molecular dynamics(MD)simulations using a graphics processing unit (GPU) has been employed in order to determine the conformational space of the methane-thiosulfonate spin label (MTSL) attached to the activation loop of the Aurora-A kinase protein and compared with quantum mechanical (QM) methods rooted on density functional theory (DFT). MD provided a wealth of information about interactions between the MTSL and the residues of the protein and on the different motional contributions to the overall dynamics of the MTSL. Data obtained from MD were seen to be in good agreement with those obtained from QM but the dynamics of the system revealed more interactions than those observed from QM methods. A strong correlation between the tumbling of the protein and the transitions of the X4 and X5 dihedral angles of the MTSL, was observed with a consequent effect also the distribution of the nitroxide(NO)group in the space. Theoretical EPR spectra calculated from opportunely selected MD frames showing interactions betw...

  3. Protective spin-labeled fluorenes maintain amyloid beta peptide in small oligomers and limit transitions in secondary structure

    Energy Technology Data Exchange (ETDEWEB)

    Altman, Robin [Univ. of California, Davis, CA (United States). Dept. of Biochemistry and Molecular Medicine; Ly, Sonny [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Physical and Life Science Directorate; Hilt, Silvia [Univ. of California, Davis, CA (United States). Dept. of Biochemistry and Molecular Medicine; Petrlova, Jitka [Univ. of California, Davis, CA (United States). Dept. of Biochemistry and Molecular Medicine; Maezawa, Izumi [Univ. of California Davis, Sacramento, CA (United States). MIND Inst. and Dept. of Pathology and Laboratory Medicine; Kálai, Tamás [Univ. of Pecs (Hungary). Inst. of Organic and Medicinal Chemistry; Hideg, Kálmán [Univ. of Pecs (Hungary). Inst. of Organic and Medicinal Chemistry; Jin, Lee-Way [Univ. of California Davis, Sacramento, CA (United States). MIND Inst. and Dept. of Pathology and Laboratory Medicine; Laurence, Ted A. [Univ. of California, Davis, CA (United States). Dept. of Biochemistry and Molecular Medicine; Voss, John C. [Univ. of California, Davis, CA (United States). Dept. of Biochemistry and Molecular Medicine

    2015-12-01

    Alzheimer’s disease is characterized by the presence of extracellular plaques comprised of amyloid beta (Aβ) peptides. Soluble oligomers of the Aβ peptide underlie a cascade of neuronal loss and dysfunction associated with Alzheimer's disease. Single particle analyses of Aβ oligomers in solution by fluorescence correlation spectroscopy (FCS) were used to provide real-time descriptions of how spin-labeled fluorenes (SLFs; bi-functional small molecules that block the toxicity of Aβ) prevent and disrupt oligomeric assemblies of Aβ in solution. The FCS results, combined with electron paramagnetic resonance spectroscopy and circular dichroism spectroscopy, demonstrate SLFs can inhibit the growth of Aβ oligomers and disrupt existing oligomers while retaining Aβ in a largely disordered state. Furthermore, while the ability of SLF to block Aβ toxicity correlates with a reduction in oligomer size, our results suggest the conformation of Aβ within the oligomer determines the toxicity of the species. Attenuation of Aβ toxicity, which has been associated primarily with the soluble oligomeric form, can be achieved through redistribution of the peptides into smaller oligomers and arrest of the fractional increase in beta secondary structure.

  4. High-resolution myocardial perfusion mapping in small animals in vivo by spin-labeling gradient-echo imaging.

    Science.gov (United States)

    Kober, Frank; Iltis, Isabelle; Izquierdo, Marguerite; Desrois, Martine; Ibarrola, Danielle; Cozzone, Patrick J; Bernard, Monique

    2004-01-01

    An ECG and respiration-gated spin-labeling gradient-echo imaging technique is proposed for the quantitative and completely noninvasive measurement and mapping of myocardial perfusion in small animals in vivo. In contrast to snapshot FLASH imaging, the spatial resolution of the perfusion maps is not limited by the heart rate. A significant improvement in image quality is achieved by synchronizing the inversion pulse to the respiration movements of the animals, thereby allowing for spontaneous respiration. High-resolution myocardial perfusion maps (in-plane resolution=234 x 468 microm2) demonstrating the quality of the perfusion measurement were obtained at 4.7 T in a group of seven freely breathing Wistar-Kyoto rats under isoflurane anesthesia. The mean perfusion value (group average +/- SD) was 5.5 +/- 0.7 ml g(-1)min(-1). In four animals, myocardial perfusion was mapped and measured under cardiac dobutamine stress. Perfusion increased to 11.1 +/- 1.9 ml g(-1)min(-1). The proposed method is particularly useful for the study of small rodents at high fields.

  5. Evaluation of spin labels for in-cell EPR by analysis of nitroxide reduction in cell extract of Xenopus laevis oocytes

    Science.gov (United States)

    Azarkh, Mykhailo; Okle, Oliver; Eyring, Philipp; Dietrich, Daniel R.; Drescher, Malte

    2011-10-01

    Spin-label electron paramagnetic resonance (SL-EPR) spectroscopy has become a powerful and useful tool for studying structure and dynamics of biomacromolecules. However, utilizing these methods at physiological temperatures for in-cell studies is hampered by reduction of the nitroxide spin labels and thus short half-lives in the cellular environment. Consequently, reduction kinetics of two structurally different nitroxides was investigated in cell extracts of Xenopus laevis oocytes using rapid-scan cw-experiments at X-band. The five member heterocyclic ring nitroxide PCA (3-carboxy-2,2,5,5-tetramethylpyrrolidinyl-1-oxy) under investigation features much higher stability against intracellular reduction than the six member ring analog TOAC (2,2,6,6-tetramethylpiperidine-N-oxyl-4-amino-4-carboxilic acid) and is therefore a suitable spin label type for in-cell EPR. The kinetic data can be described according to the Michaelis-Menten model and thus suggest an enzymatic or enzyme-mediated reduction process.

  6. Study on dipole-dipole interaction in spin labelled hemoglobin molecule by means of ESR spectroscopy; Badanie oddzialywan dipol-dipolowych w znakowanej spinowo czasteczce hemoglobiny metoda impulsowej spektroskopii EPR

    Energy Technology Data Exchange (ETDEWEB)

    Kostrzewa, A.; Froncisz, W. [Inst. Biologii Molekularnej, Uniwersytet Jagiellonski, Cracow (Poland)

    1994-12-31

    Dipole-dipole interactions in spin labelled hemoglobin molecule have been investigated by means of ESR. The spectral differences at 77 K between oxy-hemoglobin and ferry hemoglobin have been discussed. 4 refs, 3 figs, 1 tab.

  7. Membrane docking geometry of GRP1 PH domain bound to a target lipid bilayer: an EPR site-directed spin-labeling and relaxation study.

    Directory of Open Access Journals (Sweden)

    Huai-Chun Chen

    Full Text Available The second messenger lipid PIP(3 (phosphatidylinositol-3,4,5-trisphosphate is generated by the lipid kinase PI3K (phosphoinositide-3-kinase in the inner leaflet of the plasma membrane, where it regulates a broad array of cell processes by recruiting multiple signaling proteins containing PIP(3-specific pleckstrin homology (PH domains to the membrane surface. Despite the broad importance of PIP(3-specific PH domains, the membrane docking geometry of a PH domain bound to its target PIP(3 lipid on a bilayer surface has not yet been experimentally determined. The present study employs EPR site-directed spin labeling and relaxation methods to elucidate the membrane docking geometry of GRP1 PH domain bound to bilayer-embedded PIP(3. The model target bilayer contains the neutral background lipid PC and both essential targeting lipids: (i PIP(3 target lipid that provides specificity and affinity, and (ii PS facilitator lipid that enhances the PIP(3 on-rate via an electrostatic search mechanism. The EPR approach measures membrane depth parameters for 18 function-retaining spin labels coupled to the PH domain, and for calibration spin labels coupled to phospholipids. The resulting depth parameters, together with the known high resolution structure of the co-complex between GRP1 PH domain and the PIP(3 headgroup, provide sufficient constraints to define an optimized, self-consistent membrane docking geometry. In this optimized geometry the PH domain engulfs the PIP(3 headgroup with minimal bilayer penetration, yielding the shallowest membrane position yet described for a lipid binding domain. This binding interaction displaces the PIP(3 headgroup from its lowest energy position and orientation in the bilayer, but the headgroup remains within its energetically accessible depth and angular ranges. Finally, the optimized docking geometry explains previous biophysical findings including mutations observed to disrupt membrane binding, and the rapid lateral

  8. Study of a DNA Duplex by Nuclear Magnetic Resonance and Molecular Dynamics Simulations. Validation of Pulsed Dipolar Electron Paramagnetic Resonance Distance Measurements Using Triarylmethyl-Based Spin Labels.

    Science.gov (United States)

    Lomzov, Alexander A; Sviridov, Eugeniy A; Shernuykov, Andrey V; Shevelev, Georgiy Yu; Pyshnyi, Dmitrii V; Bagryanskaya, Elena G

    2016-06-16

    Pulse dipole-dipole electron paramagnetic resonance (EPR) spectroscopy (double electron-electron resonance [DEER] or pulse electron-electron double resonance [PELDOR] and double quantum coherence [DQC]) allows for measurement of distances in biomolecules and can be used at low temperatures in a frozen solution. Recently, the possibility of distance measurement in a nucleic acid at a physiological temperature using pulse EPR was demonstrated. In these experiments, triarylmethyl (TAM) radicals with long memory time of the electron spin served as a spin label. In addition, the duplex was immobilized on modified silica gel particles (Nucleosil DMA); this approach enables measurement of interspin distances close to 4.5 nm. Nevertheless, the possible influence of TAM on the structure of a biopolymer under study and validity of the data obtained by DQC are debated. In this paper, a combination of molecular dynamics (MD) and nuclear magnetic resonance (NMR) methods was used for verification of interspin distances measured by the X-band DQC method. NMR is widely used for structural analysis of biomolecules under natural conditions (room temperature and an aqueous solution). The ultraviolet (UV) melting method and thermal series (1)H NMR in the range 5-95 °C revealed the presence of only the DNA duplex in solution at oligonucleotide concentrations 1 μM to 1.1 mM at temperatures below 40 °C. The duplex structures and conformation flexibility of native and TAM-labeled DNA complexes obtained by MD simulation were the same as the structure obtained by NMR refinement. Thus, we showed that distance measurements at physiological temperatures by the X-band DQC method allow researchers to obtain valid structural information on an unperturbed DNA duplex using terminal TAM spin labels.

  9. Interactions of /sup 14/N:/sup 15/N stearic acid spin-label pairs: effects of host lipid alkyl chain length and unsaturation

    Energy Technology Data Exchange (ETDEWEB)

    Feix, J.B.; Yin, J.J.; Hyde, J.S.

    1987-06-30

    Electron-electron double resonance (ELDOR) and saturation recovery electron paramagnetic resonance (EPR) spectroscopy have been employed to examine the interactions of /sup 14/N:/sup 15/N stearic acid spin-label pairs in fluid-phase model membrane bilayers composed of a variety of phospholipids. The (/sup 14/N)-16-doxylstearate:(/sup 15/N)-16-doxylstearate (16:16) pair was utilized to measure lateral diffusion of the spin-labels, while the (/sup 14/N)-16-doxylstearate:(/sup 15/N)-5-doxylstearate (16:5) pair provided information on vertical fluctuations of the 16-doxylstearate nitroxide moiety toward the membrane surface. Three saturated host lipids of varying alkyl chain length (dimyristoylphosphatidylcholine (DMPC), dipalmitoylphosphatidylcholine (DPPC), and distearoylphosphatidylcholine (DSPC)), an ..cap alpha..-saturated, ..beta..-unsaturated lipid (1-palmitoyl-2-oleoylphosphatidylcholine (POPC)), and phosphatidylcholine from a natural source (egg yolk phosphatidylcholine (egg PC)) were utilized as host lipids. Lateral diffusion of the stearic acid spin-labels was only slightly affected by alkyl chain length at a given reduced temperature (T/sub r/) in the saturated host lipids but was significantly decreased in POPC at the same T/sub r/. Lateral diffusion in DMPC, POPC, and egg PC was quite similar at 37/sup 0/C. A strong correlation was noted between lateral diffusion constants and rotational mobility of (/sup 14/N)-16-doxylstearate. Vertical fluctuations were likewise only slightly influenced by alklyl chain length but were strongly diminished in POPC and egg PC relative to the saturated systems. This diminution of the 16:5 interaction was observed even under conditions where no differences were discernible by conventional EPR.

  10. Electron transfer flavoprotein domain II orientation monitored using double electron-electron resonance between an enzymatically reduced, native FAD cofactor, and spin labels.

    Science.gov (United States)

    Swanson, Michael A; Kathirvelu, Velavan; Majtan, Tomas; Frerman, Frank E; Eaton, Gareth R; Eaton, Sandra S

    2011-03-01

    Human electron transfer flavoprotein (ETF) is a soluble mitochondrial heterodimeric flavoprotein that links fatty acid β-oxidation to the main respiratory chain. The crystal structure of human ETF bound to medium chain acyl-CoA dehydrogenase indicates that the flavin adenine dinucleotide (FAD) domain (αII) is mobile, which permits more rapid electron transfer with donors and acceptors by providing closer access to the flavin and allows ETF to accept electrons from at least 10 different flavoprotein dehydrogenases. Sequence homology is high and low-angle X-ray scattering is identical for Paracoccus denitrificans (P. denitrificans) and human ETF. To characterize the orientations of the αII domain of P. denitrificans ETF, distances between enzymatically reduced FAD and spin labels in the three structural domains were measured by double electron-electron resonance (DEER) at X- and Q-bands. An FAD to spin label distance of 2.8 ± 0.15 nm for the label in the FAD-containing αII domain (A210C) agreed with estimates from the crystal structure (3.0 nm), molecular dynamics simulations (2.7 nm), and rotamer library analysis (2.8 nm). Distances between the reduced FAD and labels in αI (A43C) were between 4.0 and 4.5 ± 0.35 nm and for βIII (A111C) the distance was 4.3 ± 0.15 nm. These values were intermediate between estimates from the crystal structure of P. denitrificans ETF and a homology model based on substrate-bound human ETF. These distances suggest that the αII domain adopts orientations in solution that are intermediate between those which are observed in the crystal structures of free ETF (closed) and ETF bound to a dehydrogenase (open).

  11. Blood tracer kinetics in the arterial tree.

    Directory of Open Access Journals (Sweden)

    Elias Kellner

    Full Text Available Evaluation of blood supply of different organs relies on labeling blood with a suitable tracer. The tracer kinetics is linear: Tracer concentration at an observation site is a linear response to an input somewhere upstream the arterial flow. The corresponding impulse response functions are currently treated empirically without incorporating the relation to the vascular morphology of an organ. In this work we address this relation for the first time. We demonstrate that the form of the response function in the entire arterial tree is reduced to that of individual vessel segments under approximation of good blood mixing at vessel bifurcations. The resulting expression simplifies significantly when the geometric scaling of the vascular tree is taken into account. This suggests a new way to access the vascular morphology in vivo using experimentally determined response functions. However, it is an ill-posed inverse problem as demonstrated by an example using measured arterial spin labeling in large brain arteries. We further analyze transport in individual vessel segments and demonstrate that experimentally accessible tracer concentration in vessel segments depends on the measurement principle. Explicit expressions for the response functions are obtained for the major middle part of the arterial tree in which the blood flow in individual vessel segments can be treated as laminar. When applied to the analysis of regional cerebral blood flow measurements for which the necessary arterial input is evaluated in the carotid arteries, present theory predicts about 20% underestimation, which is in agreement with recent experimental data.

  12. Blood tracer kinetics in the arterial tree.

    Science.gov (United States)

    Kellner, Elias; Gall, Peter; Günther, Matthias; Reisert, Marco; Mader, Irina; Fleysher, Roman; Kiselev, Valerij G

    2014-01-01

    Evaluation of blood supply of different organs relies on labeling blood with a suitable tracer. The tracer kinetics is linear: Tracer concentration at an observation site is a linear response to an input somewhere upstream the arterial flow. The corresponding impulse response functions are currently treated empirically without incorporating the relation to the vascular morphology of an organ. In this work we address this relation for the first time. We demonstrate that the form of the response function in the entire arterial tree is reduced to that of individual vessel segments under approximation of good blood mixing at vessel bifurcations. The resulting expression simplifies significantly when the geometric scaling of the vascular tree is taken into account. This suggests a new way to access the vascular morphology in vivo using experimentally determined response functions. However, it is an ill-posed inverse problem as demonstrated by an example using measured arterial spin labeling in large brain arteries. We further analyze transport in individual vessel segments and demonstrate that experimentally accessible tracer concentration in vessel segments depends on the measurement principle. Explicit expressions for the response functions are obtained for the major middle part of the arterial tree in which the blood flow in individual vessel segments can be treated as laminar. When applied to the analysis of regional cerebral blood flow measurements for which the necessary arterial input is evaluated in the carotid arteries, present theory predicts about 20% underestimation, which is in agreement with recent experimental data.

  13. High-field ELDOR-detected NMR study of a nitroxide radical in disordered solids: Towards characterization of heterogeneity of microenvironments in spin-labeled systems

    Science.gov (United States)

    Nalepa, Anna; Möbius, Klaus; Lubitz, Wolfgang; Savitsky, Anton

    2014-05-01

    The combination of high-field EPR with site-directed spin-labeling (SDSL) techniques employing nitroxide radicals has turned out to be particularly powerful in probing the polarity and proticity characteristics of protein/matrix systems. This information is concluded from the principal components of the nitroxide Zeeman (g), nitrogen hyperfine (A) and quadrupole (P) tensors of the spin labels attached to specific sites. Recent multi-frequency high-field EPR studies underlined the complexity of the problem to treat the nitroxide microenvironment in proteins adequately due to inherent heterogeneities which result in several principal x-components of the nitroxide g-tensor. Concomitant, but distinctly different nitrogen hyperfine components could, however, not be determined from high-field cw EPR experiments owing to the large intrinsic EPR linewidth in fully protonated guest/host systems. It is shown in this work that, using the W-band (95 GHz) ELDOR- (electron-electron double resonance) detected NMR (EDNMR) method, different principal nitrogen hyperfine, Azz, and quadrupole, Pzz, tensor values of a nitroxide radical in glassy 2-propanol matrix can be measured with high accuracy. They belong to nitroxides with different hydrogen-bond situations. The satisfactory resolution and superior sensitivity of EDNMR as compared to the standard ENDOR (electron-nuclear double resonance) method are demonstrated.

  14. Optimal Blood Suppression inversion time based on breathing rates and heart rates to improve renal artery visibility in spatial labeling with multiple inversion pulses: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Yi Gang; Li, Fang; Long, Xue Ying; Liu, Hui; Wang, Xiao Yi; Liu, Jin Kang; Li, Wen Zheng [Dept. of Radiology, Xiangya Hospital, Central South University, Changsha (China); Shen, Hao [GE Healthcare, Waukesha (United States)

    2016-02-15

    To determine whether an optimal blood suppression inversion time (BSP TI) can boost arterial visibility and whether the optimal BSP TI is related to breathing rate (BR) and heart rate (HR) for hypertension subjects in spatial labeling with multiple inversion pulses (SLEEK). This prospective study included 10 volunteers and 93 consecutive hypertension patients who had undergone SLEEK at 1.5T MRI system. Firstly, suitable BSP TIs for displaying clearly renal artery were determined in 10 volunteers. Secondly, non-contrast enhanced magnetic resonance angiography with the suitable BSP TIs were performed on those hypertension patients. Then, renal artery was evaluated and an optimal BSP TI to increase arterial visibility was determined for each patient. Patients' BRs and HRs were recorded and their relationships with the optimal BSP TI were analyzed. The optimal BSP TI was negatively correlated with BR (r1 = -0.536, P1 < 0.001; and r2 = -0.535, P2 < 0.001) and HR (r1 = -0.432, P1 = 0.001; and r2 = -0.419, P2 = 0.001) for 2 readers (κ = 0.93). For improving renal arterial visibility, BSP TI = 800 ms could be applied as the optimal BSP TI when the 95% confidence interval were 17-19/min (BR1) and 74-82 bpm (HR1) for reader#1 and 17-19/min (BR2) and 74-83 bpm (HR2) for reader#2; BSP TI = 1100 ms while 14-15/min (BR1, 2) and 71-76 bpm (HR1, 2) for both readers; and BSP TI = 1400 ms when 13-16/min (BR1) and 63-68 bpm (HR1) for reader#1 and 14-15/min (BR2) and 64-70 bpm (HR2) for reader#2. In SLEEK, BSP TI is affected by patients' BRs and HRs. Adopting the optimal BSP TI based on BR and HR can improve the renal arterial visibility and consequently the working efficiency.

  15. Two-Dimensional Field-Step ELDOR. A Method for Characterizing the Motion of Spin Probes and Spin Labels in Glassy Solids

    Science.gov (United States)

    Saalmueller, J. W.; Long, H. W.; Maresch, G. G.; Spiess, H. W.

    A practical route for obtaining two-dimensional electron double-resonance spectra of radicals in disordered solids is presented in detail. It involves narrow-band pulse excitation during a magnetic field step combined with echo detection after a mixing time. The equipment and experimental procedures are described, and factors affecting the performance of the field-jump coil, spectral resolution, and sensitivity are thoroughly discussed. Simulated spectra, which take into account distributions of correlation times, show the spectral features that can be observed with this technique. These simulations have been improved over previous work by taking into account g-tensor fluctuations, which is the dominant effect in determining the anisotropy of the electron spin-lattice relaxation. Data for nitroxide radicals in polycarbonate at 110 K are analyzed and an orientation averaged nuclear spin-lattice relaxation time of 82 ± 13 μs and an electron spin-lattice relaxation time for radicals oriented along the zdirection (slowest relaxation) of 23 ± 4 μs are measured. Simulations show that this relaxation is caused by highly restricted liberational motion with a distribution of correlation times having mean of 0.1 μs and a width of about 0.8 decades in combination with a very narrow mode having a correlation time of 10 ps.

  16. Calibrated MRI to evaluate cerebral hemodynamics in patients with an internal carotid artery occlusion

    NARCIS (Netherlands)

    De Vis, Jill B.; Petersen, Esben T.; Bhogal, Alex; Hartkamp, Nolan S.; Klijn, Catharina J. M.; Kappelle, L. J.; Hendrikse, J.

    2015-01-01

    The purpose of this study was to assess whether calibrated magnetic resonance imaging (MRI) can identify regional variances in cerebral hemodynamics caused by vascular disease. For this, arterial spin labeling (ASL)/blood oxygen level-dependent (BOLD) MRI was performed in 11 patients (65 +/- 7 years

  17. Planning-free cerebral blood flow territory mapping in patients with intracranial arterial stenosis.

    Science.gov (United States)

    Arteaga, Daniel F; Strother, Megan K; Davis, L Taylor; Fusco, Matthew R; Faraco, Carlos C; Roach, Brent A; Scott, Allison O; Donahue, Manus J

    2016-07-07

    A noninvasive method for quantifying cerebral blood flow and simultaneously visualizing cerebral blood flow territories is vessel-encoded pseudocontinuous arterial spin labeling MRI. However, obstacles to acquiring such information include limited access to the methodology in clinical centers and limited work on how clinically acquired vessel-encoded pseudocontinuous arterial spin labeling data correlate with gold-standard methods. The purpose of this work is to develop and validate a semiautomated pipeline for the online quantification of cerebral blood flow maps and cerebral blood flow territories from planning-free vessel-encoded pseudocontinuous arterial spin labeling MRI with gold-standard digital subtraction angiography. Healthy controls (n = 10) and intracranial atherosclerotic disease patients (n = 34) underwent 3.0 T MRI imaging including vascular (MR angiography) and hemodynamic (cerebral blood flow-weighted arterial spin labeling) MRI. Patients additionally underwent catheter and/or CT angiography. Variations in cross-territorial filling were grouped according to diameters of circle of Willis vessels in controls. In patients, Cohen's k-statistics were computed to quantify agreement in perfusion patterns between vessel-encoded pseudocontinuous arterial spin labeling and angiography. Cross-territorial filling patterns were consistent with circle of Willis anatomy. The intraobserver Cohen's k-statistics for cerebral blood flow territory and digital subtraction angiography perfusion agreement were 0.730 (95% CI = 0.593-0.867; reader one) and 0.708 (95% CI = 0.561-0.855; reader two). These results support the feasibility of a semiautomated pipeline for evaluating major neurovascular cerebral blood flow territories in patients with intracranial atherosclerotic disease.

  18. Functional localization in the human brain: Gradient-echo, spin-echo, and arterial spin-labeling fMRI compared with neuronavigated TMS.

    NARCIS (Netherlands)

    Diekhoff, S.; Uludag, K.; Sparing, R.; Tittgemeyer, M.; von Cramon, D.Y.; Grefkes, C.

    2010-01-01

    A spatial mismatch of up to 14 mm between optimal transcranial magnetic stimulation (TMS) site and functional magnetic resonance imaging (fMRI) signal has consistently been reported for the primary motor cortex. The underlying cause might be the effect of magnetic susceptibility around large drainin

  19. Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Juan; Sun, Gang; Yu, Bling Bing; Li, Min; Li, Guo Ying; Peng, Zhao Hui; Zhang, Xu Ping [Dept. of Medical Imaging, Jinan Military General Hospital, Jinan (China); Lu, Yang [Dept. of Radiology, University of Illinois College of Medicine, Illinois (United States)

    2012-11-15

    To explore the usefulness of 320-slice CT angiography (CTA) for evaluating the course of the anterior ethmoidal artery (AEA) and its relationship with adjacent structures by using three-dimensional (3D) spin digital subtraction angiography (DSA) as standard reference. From December 2008 to December 2010, 32 patients with cerebrovascular disease, who underwent both cranial 3D spin DSA and 320-slice CTA within a 30 day period from each other, were retrospectively reviewed. AEA course in ethmoid was analyzed in DSA and CTA. In addition, adjacent bony landmarks (bony notch in medial orbital wall, anterior ethmoidal canal, and anterior ethmoidal sulcus) were evaluated with CTA using the MPR technique oriented along the axial, coronal and oblique coronal planes in all patients. The dose length product (DLP) for CTA and the dose-area product (DAP) for 3D spin DSA were recorded. Effective dose (ED) was calculated. The entire course of the AEA was seen in all 32 cases (100%) with 3D spine DSA and in 29 of 32 cases (90.1%) with 320-slice CTA, with no significant difference (p = 0.24). In three cases where AEA was not visualized on 320-slice CTA, two were due to the dominant posterior ethmoidal artery, while the remaining case was due to diminutive AEA. On MPR images of 320-slice CT, a bony notch in the orbital medial walls was detected in all cases (100%, 64 of 64); anterior ethmoidal canal was seen in 28 of 64 cases (43.8%), and the anterior ethmoidal sulcus was seen in 63 of 64 cases (98.4%). The mean effective dose in CTA was 0.6 {+-} 0.25 mSv, which was significantly lower than for 3D spin DSA (1.3 {+-} 0.01 mSv) (p < 0.001). 320-slice CTA has a similar detection rate for AEA to that of 3D spin DSA; however, it is noninvasive, and may be preferentially used for the evaluation of AEA and its adjacent bony variations and pathologic changes in preoperative patients with paranasal sinus diseases.

  20. Structural and dynamic study of the tetramerization region of non-erythroid alpha-spectrin: a frayed helix revealed by site-directed spin labeling electron paramagnetic resonance.

    Science.gov (United States)

    Li, Qufei; Fung, L W-M

    2009-01-13

    The N-terminal region of alpha-spectrin is responsible for its association with beta-spectrin in a heterodimer, forming functional tetramers. Non-erythroid alpha-spectrin (alphaII-spectrin) has a significantly higher association affinity for beta-spectrin than the homologous erythroid alpha-spectrin (alphaI-spectrin). We have previously determined the solution structure of the N-terminal region of alphaI-spectrin by NMR methods, but currently no structural information is available for alphaII-spectrin. We have used cysteine scanning, spin labeling electron paramagnetic resonance (EPR), and isothermal titration calorimetry (ITC) methods to study the tetramerization region of alphaII-spectrin. EPR data clearly show that, in alphaII-spectrin, the first nine N-terminal residues were unstructured, followed by an irregular helix (helix C'), frayed at the N-terminal end, but rigid at the C-terminal end, which merges into the putative triple-helical structural domain. The region corresponding to the important unstructured junction region linking helix C' to the first structural domain in alphaI-spectrin was clearly structured. On the basis of the published model for aligning helices A', B', and C', important interactions among residues in helix C' of alphaI- and alphaII-spectrin and helices A' and B' of betaI- and betaII-spectrin are identified, suggesting similar coiled coil helical bundling for spectrin I and II in forming tetramers. The differences in affinity are likely due to the differences in the conformation of the junction regions. Equilibrium dissociation constants of spin-labeled alphaII and betaI complexes from ITC measurements indicate that residues 15, 19, 37, and 40 are functionally important residues in alphaII-spectrin. Interestingly, all four corresponding homologous residues in alphaI-spectrin (residues 24, 28, 46, and 49) have been reported to be clinically significant residues involved in hematological diseases.

  1. Advanced Developments of Electron Spin Labeling as High-Resolution Sensors of Protein Structure and Conformational Switching

    Science.gov (United States)

    2007-11-02

    Myoglobin (Myb) and Cellular Retinol Binding Protein (CRBP) were prepared, and the corresponding EPR spectra analyzed by simulation techniques. In...unprecedented level of sophistication in interpretation of the EPR spectra of labeled proteins, and establish the feasibility of separating structural and...protein as well as local structure, but to date the level of interpretation has been largely qualitative and it has not been possible to separate the

  2. Statistical design and analysis of label-free LC-MS proteomic experiments: a case study of coronary artery disease.

    Science.gov (United States)

    Clough, Timothy; Braun, Siegmund; Fokin, Vladimir; Ott, Ilka; Ragg, Susanne; Schadow, Gunther; Vitek, Olga

    2011-01-01

    This chapter presents a case study, which applies statistical design and analysis to an LC-MS-based -investigation of subjects with coronary artery disease. First, we discuss the principles of statistical -experimental design, and the specification of an Analysis of Variance (ANOVA) model that describes the major sources of variation in the data. Second, we discuss procedures for detecting differentially abundant proteins, estimating protein abundance in individual samples, testing predefined groups of proteins for enrichment in differential abundance, and calculating sample size for a future experiment. The discussion is accompanied by examples of computer code implemented in the open-source statistical software R, which can be followed for an independent implementation of a similar investigation.

  3. Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jinhee; Kim, Bom-yi; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin; Kim, Bum-soo [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, Seoul (Korea, Republic of); Schmitt, Peter [Siemens AG, Healthcare Sector, Erlangen (Germany); Kim, Inseong; Paek, Munyoung [Siemens AG, Healthcare, Seoul (Korea, Republic of)

    2014-04-15

    This study aimed to evaluate the feasibility of non-contrast-enhanced 4D magnetic resonance angiography (NCE 4D MRA) with signal targeting with alternative radiofrequency (STAR) spin labeling and variable flip angle (VFA) sampling in the assessment of dural arteriovenous fistula (DAVF) in the transverse sinus. Nine patients underwent NCE 4D MRA for the evaluation of DAVF in the transverse sinus at 3 T. One patient was examined twice, once before and once after the interventional treatment. All patients also underwent digital subtraction angiography (DSA) and/or contrast-enhanced magnetic resonance angiography (CEMRA). For the acquisition of NCE 4D MRA, a STAR spin tagging method was used, and a VFA sampling was applied in the data readout module instead of a constant flip angle. Two readers evaluated the NCE 4D MRA data for the diagnosis of DAVF and its type with consensus. The results were compared with those from DSA and/or CEMRA. All patients underwent NCE 4D MRA without any difficulty. Among seven patients with patent DAVFs, all cases showed an early visualization of the transverse sinus on NCE 4D MRA. Except for one case, the type of DAVF of NCE 4D MRA was agreed with that of reference standard study. Cortical venous reflux (CVR) was demonstrated in two cases out of three patients with CVR. NCE 4D MRA with STAR tagging and VFA sampling is technically and clinically feasible and represents a promising technique for assessment of DAVF in the transverse sinus. Further technical developments should aim at improvements of spatial and temporal coverage. (orig.)

  4. Probing Structural Dynamics and Topology of the KCNE1 Membrane Protein in Lipid Bilayers via Site-Directed Spin Labeling and Electron Paramagnetic Resonance Spectroscopy.

    Science.gov (United States)

    Sahu, Indra D; Craig, Andrew F; Dunagan, Megan M; Troxel, Kaylee R; Zhang, Rongfu; Meiberg, Andrew G; Harmon, Corrinne N; McCarrick, Robert M; Kroncke, Brett M; Sanders, Charles R; Lorigan, Gary A

    2015-10-20

    KCNE1 is a single transmembrane protein that modulates the function of voltage-gated potassium channels, including KCNQ1. Hereditary mutations in the genes encoding either protein can result in diseases such as congenital deafness, long QT syndrome, ventricular tachyarrhythmia, syncope, and sudden cardiac death. Despite the biological significance of KCNE1, the structure and dynamic properties of its physiologically relevant native membrane-bound state are not fully understood. In this study, the structural dynamics and topology of KCNE1 in bilayered lipid vesicles was investigated using site-directed spin labeling (SDSL) and electron paramagnetic resonance (EPR) spectroscopy. A 53-residue nitroxide EPR scan of the KCNE1 protein sequence including all 27 residues of the transmembrane domain (45-71) and 26 residues of the N- and C-termini of KCNE1 in lipid bilayered vesicles was analyzed in terms of nitroxide side-chain motion. Continuous wave-EPR spectral line shape analysis indicated the nitroxide spin label side-chains located in the KCNE1 TMD are less mobile when compared to the extracellular region of KCNE1. The EPR data also revealed that the C-terminus of KCNE1 is more mobile when compared to the N-terminus. EPR power saturation experiments were performed on 41 sites including 18 residues previously proposed to reside in the transmembrane domain (TMD) and 23 residues of the N- and C-termini to determine the topology of KCNE1 with respect to the 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC)/1-palmitoyl-2-oleoyl-sn-glycero-3-phospho-(1'-rac-glycerol) (POPG) lipid bilayers. The results indicated that the transmembrane domain is indeed buried within the membrane, spanning the width of the lipid bilayer. Power saturation data also revealed that the extracellular region of KCNE1 is solvent-exposed with some of the portions partially or weakly interacting with the membrane surface. These results are consistent with the previously published solution NMR

  5. Global structure of a three-way junction in a phi29 packaging RNA dimer determined using site-directed spin labeling.

    Science.gov (United States)

    Zhang, Xiaojun; Tung, Chang-Shung; Sowa, Glenna Z; Hatmal, Ma'mon M; Haworth, Ian S; Qin, Peter Z

    2012-02-08

    The condensation of bacteriophage phi29 genomic DNA into its preformed procapsid requires the DNA packaging motor, which is the strongest known biological motor. The packaging motor is an intricate ring-shaped protein/RNA complex, and its function requires an RNA component called packaging RNA (pRNA). Current structural information on pRNA is limited, which hinders studies of motor function. Here, we used site-directed spin labeling to map the conformation of a pRNA three-way junction that bridges binding sites for the motor ATPase and the procapsid. The studies were carried out on a pRNA dimer, which is the simplest ring-shaped pRNA complex and serves as a functional intermediate during motor assembly. Using a nucleotide-independent labeling scheme, stable nitroxide radicals were attached to eight specific pRNA sites without perturbing RNA folding and dimer formation, and a total of 17 internitroxide distances spanning the three-way junction were measured using Double Electron-Electron Resonance spectroscopy. The measured distances, together with steric chemical constraints, were used to select 3662 viable three-way junction models from a pool of 65 billion. The results reveal a similar conformation among the viable models, with two of the helices (H(T) and H(L)) adopting an acute bend. This is in contrast to a recently reported pRNA tetramer crystal structure, in which H(T) and H(L) stack onto each other linearly. The studies establish a new method for mapping global structures of complex RNA molecules, and provide information on pRNA conformation that aids investigations of phi29 packaging motor and developments of pRNA-based nanomedicine and nanomaterial.

  6. Global Structure of a Three-Way Junction in a Phi29 Packaging RNA Dimer Determined Using Site-Directed Spin Labeling

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiaojun; Tung, Chang-Shung; Sowa, Glenna; Hatmal, Ma' mon M.; Haworth, Ian S.; Qin, Peter Z.

    2012-02-08

    The condensation of bacteriophage phi29 genomic DNA into its preformed procapsid requires the DNA packaging motor, which is the strongest known biological motor. The packaging motor is an intricate ring-shaped protein/RNA complex, and its function requires an RNA component called packaging RNA (pRNA). Current structural information on pRNA is limited, which hinders studies of motor function. Here, we used site-directed spin labeling to map the conformation of a pRNA three-way junction that bridges binding sites for the motor ATPase and the procapsid. The studies were carried out on a pRNA dimer, which is the simplest ring-shaped pRNA complex and serves as a functional intermediate during motor assembly. Using a nucleotide-independent labeling scheme, stable nitroxide radicals were attached to eight specific pRNA sites without perturbing RNA folding and dimer formation, and a total of 17 internitroxide distances spanning the three-way junction were measured using Double Electron-Electron Resonance spectroscopy. The measured distances, together with steric chemical constraints, were used to select 3662 viable three-way junction models from a pool of 65 billion. The results reveal a similar conformation among the viable models, with two of the helices (HT and HL) adopting an acute bend. This is in contrast to a recently reported pRNA tetramer crystal structure, in which HT and HL stack onto each other linearly. The studies establish a new method for mapping global structures of complex RNA molecules, and provide information on pRNA conformation that aids investigations of phi29 packaging motor and developments of pRNA-based nanomedicine and nanomaterial.

  7. Detection of alpha-helical coiled-coil dimer formation by spin-labeled synthetic peptides: a model parallel coiled-coil peptide and the antiparallel coiled coil formed by a replica of the ProP C-terminus.

    Science.gov (United States)

    Hillar, Alexander; Tripet, Brian; Zoetewey, David; Wood, Janet M; Hodges, Robert S; Boggs, Joan M

    2003-12-30

    Electron paramagnetic resonance spectroscopy was used to determine relative peptide orientation within homodimeric, alpha-helical coiled-coil structures. Introduction of cysteine (Cys) residues into peptides/proteins for spin labeling allows detection of their oligomerization from exchange broadening or dipolar interactions between residues within 25 A of each other. Two synthetic peptides containing Cys substitutions were used: a 35-residue model peptide and the 30-residue ProP peptide. The model peptide is known to form a stable, parallel homodimeric coiled coil, which is partially destabilized by Cys substitutions at heptad a and d positions (peptides C30a and C33d). The ProP peptide, a 30-residue synthetic peptide, corresponds to residues 468-497 of osmoregulatory transporter ProP from Escherichia coli. It forms a relatively unstable, homodimeric coiled coil that is predicted to be antiparallel in orientation. Cys was introduced in heptad g positions of the ProP peptide, near the N-terminus (K473C, creating peptide C473g) or closer to the center of the sequence (E480C, creating peptide C480g). In contrast to the destabilizing effect of Cys substitution at the core heptad a or d positions of model peptides C30a and C33d, circular dichroism spectroscopy showed that Cys substitutions at the heptad g positions of the ProP peptide had little or no effect on coiled-coil stability. Thermal denaturation analysis showed that spin labeling increased the stability of the coiled coil for all peptides. Strong exchange broadening was detected for both C30a and C33d, in agreement with a parallel structure. EPR spectra of C480g had a large hyperfine splitting of about 90 G, indicative of strong dipole-dipole interactions and a distance between spin-labeled residues of less than 9 A. Spin-spin interactions were much weaker for C473g. These results supported the hypothesis that the ProP peptide primarily formed an antiparallel coiled coil, since formation of a parallel dimer

  8. Surface electrostatics of lipid bilayers by EPR of a pH-sensitive spin-labeled lipid.

    Science.gov (United States)

    Voinov, Maxim A; Rivera-Rivera, Izarys; Smirnov, Alex I

    2013-01-08

    Many biophysical processes such as insertion of proteins into membranes and membrane fusion are governed by bilayer electrostatic potential. At the time of this writing, the arsenal of biophysical methods for such measurements is limited to a few techniques. Here we describe a, to our knowledge, new spin-probe electron paramagnetic resonance (EPR) approach for assessing the electrostatic surface potential of lipid bilayers that is based on a recently synthesized EPR probe (IMTSL-PTE) containing a reversibly ionizable nitroxide tag attached to the lipids' polar headgroup. EPR spectra of the probe directly report on its ionization state and, therefore, on electrostatic potential through changes in nitroxide magnetic parameters and the degree of rotational averaging. Further, the lipid nature of the probe provides its full integration into lipid bilayers. Tethering the nitroxide moiety directly to the lipid polar headgroup defines the location of the measured potential with respect to the lipid bilayer interface. Electrostatic surface potentials measured by EPR of IMTSL-PTE show a remarkable (within ±2%) agreement with the Gouy-Chapman theory for anionic DMPG bilayers in fluid (48°C) phase at low electrolyte concentration (50 mM) and in gel (17°C) phase at 150-mM electrolyte concentration. This agreement begins to diminish for DMPG vesicles in gel phase (17°C) upon varying electrolyte concentration and fluid phase bilayers formed from DMPG/DMPC and POPG/POPC mixtures. Possible reasons for such deviations, as well as the proper choice of an electrostatically neutral reference interface, have been discussed. Described EPR method is expected to be fully applicable to more-complex models of cellular membranes.

  9. Site-directed spin-labeling of DNA by the azide-alkyne 'click' reaction: nanometer distance measurements on 7-deaza-2'-deoxyadenosine and 2'-deoxyuridine nitroxide conjugates spatially separated or linked to a 'dA-dT' base pair.

    Science.gov (United States)

    Ding, Ping; Wunnicke, Dorith; Steinhoff, Heinz-Jürgen; Seela, Frank

    2010-12-27

    Nucleobase-directed spin-labeling by the azide-alkyne 'click' (CuAAC) reaction has been performed for the first time with oligonucleotides. 7-Deaza-7-ethynyl-2'-deoxyadenosine (1) and 5-ethynyl-2'-deoxyuridine (2) were chosen to incorporate terminal triple bonds into DNA. Oligonucleotides containing 1 or 2 were synthesized on a solid phase and spin labeling with 4-azido-2,2,6,6-tetramethylpiperidine 1-oxyl (4-azido-TEMPO, 3) was performed by post-modification in solution. Two spin labels (3) were incorporated with high efficiency into the DNA duplex at spatially separated positions or into a 'dA-dT' base pair. Modification at the 5-position of the pyrimidine base or at the 7-position of the 7-deazapurine residue gave steric freedom to the spin label in the major groove of duplex DNA. By applying cw and pulse EPR spectroscopy, very accurate distances between spin labels, within the range of 1-2 nm, were measured. The spin-spin distance was 1.8±0.2 nm for DNA duplex 17(dA*(7,10))⋅11 containing two spin labels that are separated by two nucleotides within one individual strand. A distance of 1.4±0.2 nm was found for the spin-labeled 'dA-dT' base pair 15(dA*(7))⋅16(dT*(6)). The 'click' approach has the potential to be applied to all four constituents of DNA, which indicates the universal applicability of the method. New insights into the structural changes of canonical or modified DNA are expected to provide additional information on novel DNA structures, protein interaction, DNA architecture, and synthetic biology.

  10. Direct comparison of local cerebral blood flow rates measured by MRI arterial spin-tagging and quantitative autoradiography in a rat model of experimental cerebral ischemia.

    Science.gov (United States)

    Ewing, James R; Wei, Ling; Knight, Robert A; Pawa, Swati; Nagaraja, Tavarekere N; Brusca, Thomas; Divine, George W; Fenstermacher, Joseph D

    2003-02-01

    The present study determined cerebral blood flow (CBF) in the rat using two different magnetic resonance imaging (MRI) arterial spin-tagging (AST) methods and 14C-iodoantipyrine (IAP)-quantitative autoradiography (QAR), a standard but terminal technique used for imaging and quantitating CBF, and compared the resulting data sets to assess the precision and accuracy of the different techniques. Two hours after cerebral ischemia was produced in eight rats via permanent occlusion of one middle cerebral artery (MCA) with an intraluminal suture, MRI-CBF was measured over a 2.0-mm coronal slice using single-coil AST, and tissue magnetization was assessed by either a spin-echo (SE) or a variable tip-angle gradient-echo (VTA-GE) readout. Subsequently ( approximately 2.5 hours after MCA occlusion), CBF was assayed by QAR with the blood flow indicator 14C-IAP, which produced coronal images of local flow rates every 0.4 mm along the rostral-caudal axis. The IAP-QAR images that spanned the 2-mm MRI slice were selected, and regional flow rates (i.e., local CBF [lCBF]) were measured and averaged across this set of images by both the traditional approach, which involved reader interaction and avoidance of sectioning artifacts, and a whole film-scanning technique, which approximated total radioactivity in the entire MRI slice with minimal user bias. After alignment and coregistration, the concordance of the CBF rates generated by the two QAR approaches and the two AST methods was examined for nine regions of interest in each hemisphere. The QAR-lCBF rates were higher with the traditional method of assaying tissue radioactivity than with the MRI-analog approach; although the two sets of rates were highly correlated, the scatter was broad. The flow rates obtained with the whole film-scanning technique were chosen for subsequent comparisons to MRI-CBF results because of the similarity in tissue "sampling" among these three methods. As predicted by previous modeling, "true" flow rates

  11. 自旋标记查耳酮类化合物的合成及抗肿瘤活性%Synthesis and biological evaluation of spin-labelled derivatives of chalcones

    Institute of Scientific and Technical Information of China (English)

    金岩; 刘杰; 陈世武

    2013-01-01

    目的 发现高效自旋标记查耳酮类抗肿瘤药物.方法 通过乙酰苯与芳醛在碱性条件下缩合生成查耳酮,进一步与稳定氮氧自由基酸发生酰化反应合成了一系列自旋标记的查耳酮化合物,用MTT法对合成的化合物进行体外抗肿瘤活性研究(P3SS、A549、HT-29、MDA-MB-231、8GC-7901、BEL-7402).结果 化合物3a和3c在10 μg/mL时对所有测试瘤株的抑制率均大于60%.结论 自旋标记的查耳酮酰胺类化合物具有较高的体外抗肿瘤活性.%Objective To find new spin labelled chalcones as anti-tumor drugs with potent activities and low toxicities. Methods A series spin labelled chalcones were synthesized by condensation reaction of aromatic aldehyde and acetpophenone, following acetylation. The cytotoxic activities against six tumor cell lines (P388, A-549, HT-29, MDA-MB-231, SGC-7901, BEL-7402) in vitro of synthetic compounds were also evaluated by MTT method. Results Compounds 3a and 3c showed more than 60% proliferation inhibitions against all six tested tumor cell lines in vitro. Conclusion The amides of spin-labelled chalcones present better anti-tumor activities in vitro.

  12. Dynamic nuclear spin polarization

    Energy Technology Data Exchange (ETDEWEB)

    Stuhrmann, H.B. [GKSS-Forschungszentrum Geesthacht GmbH (Germany)

    1996-11-01

    Polarized neutron scattering from dynamic polarized targets has been applied to various hydrogenous materials at different laboratories. In situ structures of macromolecular components have been determined by nuclear spin contrast variation with an unprecedented precision. The experiments of selective nuclear spin depolarisation not only opened a new dimension to structural studies but also revealed phenomena related to propagation of nuclear spin polarization and the interplay of nuclear polarisation with the electronic spin system. The observation of electron spin label dependent nuclear spin polarisation domains by NMR and polarized neutron scattering opens a way to generalize the method of nuclear spin contrast variation and most importantly it avoids precontrasting by specific deuteration. It also likely might tell us more about the mechanism of dynamic nuclear spin polarisation. (author) 4 figs., refs.

  13. MRA与动脉质子自旋标记联合对短暂性脑缺血预后评估的应用%The application of magnetic resonance angiography in combination with arteiral spin labeling proton in evaluating the prognosis of transient ischemic attack

    Institute of Scientific and Technical Information of China (English)

    张丽雅; 周旭峰; 李华丽; 高志翔; 卢超; 白喜恩

    2011-01-01

    目的 评价磁共振血管造影(magnetic resonance angiography,MRA)及动脉质子自旋标记(arteiral spin labeling proton,ASL)联合对短暂性脑缺血发作(transient ischemic attack,TIA)预后评估价值.方法 90例颈动脉TIA患者根据DWI表现分为单纯型TIA 和暂时性症状合并梗死(transient symptoms associated with infarction,TSI型)2组.90例患者均分别行MRA及ASL检查,根据MRA及ASL表现分为4型:A型(MRA及ASL均异常)、B型(MRA及ASL均正常)、C型(MRA正常,ASL异常)、D型(MRA异常,ASL正常).结果 在A型表现里,单纯型TIA占20%,TSI型占80%;在B型的表现里,单纯型TIA占94.7%,TSI型占5.3%.A、B 2型在2组间进行比较,差异有统计学意义(P<0.01).结论 MRA及ASL联合检查可对TIA患者脑血管和脑灌注进行诊断,为临床对TIA患者预后评估提供影像学依据.%Objective To evaluate the value of magnetic resonance angiography( MRA) combined with arteiral spin labeling proton ( ASI )in evaluating the prognosis of transicnt ischemic attack( TIA). Methods 90 patients with internal carotid artery transient ischemic attack ( TIA) were devidcd into simplex type and transicnt symptoms associated with infarction(TSI) type based on the manifestations of DWI. All cases underwent MRA and ASL examination. TIA could be devided into 4 types according to the manifestations of MRA and ASL: type A (abnormal on both MRA and ASL) , type B (normal on both MRA and ASL) , type C ( normal MRA and abnormal ASL findings) , type D (abnormal MRA and normal ASL findings). Results Simplex type accounted for 20% and TSI type accountcd for 80% in type A; simplex type accounted for 94. 7% and TSI type accounted for 5. 3% in type B. type A and type B had statistically significant between each other (P<O. 01). Conclusion MRA in combination with ASL is a good method in diagnosis of TIA, and which is of great significance in estimating the diagnosis and prognosis of TIA .

  14. Combination of {sup 15}N reverse labeling and afterglow spectroscopy for assigning membrane protein spectra by magic-angle-spinning solid-state NMR: application to the multidrug resistance protein EmrE

    Energy Technology Data Exchange (ETDEWEB)

    Banigan, James R.; Gayen, Anindita; Traaseth, Nathaniel J., E-mail: traaseth@nyu.edu [New York University, Department of Chemistry (United States)

    2013-04-15

    Magic-angle-spinning (MAS) solid-state NMR spectroscopy has emerged as a viable method to characterize membrane protein structure and dynamics. Nevertheless, the spectral resolution for uniformly labeled samples is often compromised by redundancy of the primary sequence and the presence of helical secondary structure that results in substantial resonance overlap. The ability to simplify the spectrum in order to obtain unambiguous site-specific assignments is a major bottleneck for structure determination. To address this problem, we used a combination of {sup 15}N reverse labeling, afterglow spectroscopic techniques, and frequency-selective dephasing experiments that dramatically improved the ability to resolve peaks in crowded spectra. This was demonstrated using the polytopic membrane protein EmrE, an efflux pump involved in multidrug resistance. Residues preceding the {sup 15}N reverse labeled amino acid were imaged using a 3D NCOCX afterglow experiment and those following were recorded using a frequency-selective dephasing experiment. Our approach reduced the spectral congestion and provided a sensitive way to obtain chemical shift assignments for a membrane protein where no high-resolution structure is available. This MAS methodology is widely applicable to the study of other polytopic membrane proteins in functional lipid bilayer environments.

  15. Balanced Steady State Free Precession for Arterial Spin Labeling MRI: Initial Experience for Blood Flow Mapping in Human Brain, Retina, and Kidney

    Science.gov (United States)

    Park, Sung-Hong; Wang, Danny J.J.; Duong, Timothy Q.

    2013-01-01

    We implemented pseudo-continuous ASL (pCASL) with 2D and 3D balanced steady state free precession (bSSFP) readout for mapping blood flow in the human brain, retina, and kidney, free of distortion and signal dropout, which are typically observed in the most commonly used echo-planar imaging acquisition. High resolution functional brain imaging in the human visual cortex was feasible with 3D bSSFP pCASL. Blood flow of the human retina could be imaged with pCASL and bSSFP in conjunction with a phase cycling approach to suppress the banding artifacts associated with bSSFP. Furthermore, bSSFP based pCASL enabled us to map renal blood flow within a single breath hold. Control and test-retest experiments suggested that the measured blood flow values in retina and kidney were reliable. Because there is no specific imaging tool for mapping human retina blood flow and the standard contrast agent technique for mapping renal blood flow can cause problems for patients with kidney dysfunction, bSSFP based pCASL may provide a useful tool for the diagnosis of retinal and renal diseases and can complement existing imaging techniques. PMID:23664680

  16. Effect of open-label infusion of an apoA-I-containing particle (CER-001) on RCT and artery wall thickness in patients with FHA

    NARCIS (Netherlands)

    Kootte, Ruud S.; Smits, Loek P.; van der Valk, Fleur M.; Dasseux, Jean-Louis; Keyserling, Constance H.; Barbaras, Ronald; Paolini, John F.; Santos, Raul D.; van Dijk, Theo H.; Dallinga-van Thie, Geesje M.; Nederveen, Aart J.; Mulder, Willem J. M.; Hovingh, G. Kees; Kastelein, John J. P.; Groen, Albert K.; Stroes, Erik S.

    2015-01-01

    Reverse cholesterol transport (RCT) contributes to the anti-atherogenic effects of HDL. Patients with the orphan disease, familial hypoalphalipoproteinemia (FHA), are characterized by decreased tissue cholesterol removal and an increased atherogenic burden. We performed an open-label uncontrolled pr

  17. Clinical result of intra-arterial lymphocyte injection therapy for treatment of lymphedema and the evaluation of the efficacy of the therapy. Quantitative analysis by an injection of {sup 111}In-labeled lymphocytes and by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Masanori; Kitagawa, Tetsuya; Hori, Takaki; Katoh, Itsuo; Harada, Masashi; Matsumoto, Takahiro; Nishitani, Hiromu [Tokushima Univ. (Japan). School of Medicine

    1995-11-01

    We have employed the intra-arterial lymphocytes injection therapy for treatment of lymphedema of the limbs with various causes. In the present study, we observed the clinical outcome of our therapy in 38 patients with lymphedema of the limbs. Results showed that the therapy was effective in 26 of 38 patients (68% of the total). Moreover, a marked efficacy was obtained in 13 of 38 patients (34% of the total). In the latest 5 patients, to evaluate the efficacy of our therapy, we examined the distribution of the {sup 111}In-oxine labeled lymphocytes injected into the proximal artery of the affected limb. The radioactivities of the affected limbs were apparently higher than that of the healthy limbs in effective cases. Moreover, MR imaging showed that the reduction of STIR ratio and T{sub 2} ratio well correlate with the results of clinical course. Thus, the efficacy of the lymphocyte injection therapy is able to be evaluated by radiolabeled lymphocytes and MR imaging. (author).

  18. Clinical usefulness of {sup 123}I-labeled 15-iodophenyl 3-methyl pentadecanoic acid (BMIPP) myocardial SPECT in coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Kazuki [Kyoto Prefectural Univ. of Medicine (Japan)

    1998-01-01

    {sup 123}I-BMIPP (BMIPP) myocardial SPECT was carried out in 22 patients with acute myocardial infarction, in 20 patients with unstable angina pectoris, in 80 patients with effort angina pectoris and in 25 patients with vasospastic angina pectoris. In a study of patients with acute myocardial infarction, BMIPP uptake was less than thallium perfusion in areas of myocardial infarction. Such discordant BMIPP/thallium uptake was often observed in areas with recanalized arteries, and in those with abnormal wall motion. In the areas showing discordant BMIPP/thallium uptake, the wall motion abnormalities improved in the chronic phase after recanalization therapy. Therefore, the discordant BMIPP/thallium uptake might represent asynergic but viable regions, and might be valuable in predicting the improvement of wall motion abnormalities. In a study of patients with unstable angina pectoris, the severity of regional wall motion abnormality was significantly correlated with severity of BMIPP uptake. BMIPP imaging well visualized the culprit regions in patients with unstable angina pectoris. In a study of patients with effort angina pectoris, the abnormal BMIPP images were associated with severe coronary artery stenosis of more than 90% and with multivessel stenosis. BMIPP imaging could detect patients with functionally severe coronary artery disease and help to guide coronary angioplasty in patients with effort angina. In a study of patients with vasospastic angina pectoris, metabolic abnormality assessed by BMIPP was associated with left ventricular asynergy and spastic regions. Those abnormalities also correlated inversely with the period from the last attack, and improved after medical treatment. (K.H.)

  19. Effects of iloprost combined with low dose tadalafil in adult congenital heart disease patients with severe pulmonary arterial hypertension: a single-center,open-label controlled study

    Institute of Scientific and Technical Information of China (English)

    张曹进

    2014-01-01

    Objective To evaluate the therapy efficacy of iloprost combined with low dose tadalafil in adult congenital heart disease(CHD)patients with severe pulmonary arterial hypertension(PAH).Methods Adult CHD patients with severe PAH were included and divided into the sequential combination therapy group[iloprost:10μg/inhalation,6 times per day for 6 months,and then add oral tadalafil(5 mg/d)till 12 months,n=32]and upfront combination therapy group[iloprost:10μg/inhalation,6 times per day combined with oral tadalafil(5 mg)

  20. Food Labels

    Science.gov (United States)

    ... Loss Surgery? A Week of Healthy Breakfasts Shyness Food Labels KidsHealth > For Teens > Food Labels Print A ... have at least 95% organic ingredients. continue Making Food Labels Work for You The first step in ...

  1. Nano-Mole Scale Side-Chain Signal Assignment by 1H-Detected Protein Solid-State NMR by Ultra-Fast Magic-Angle Spinning and Stereo-Array Isotope Labeling

    KAUST Repository

    Wang, Songlin

    2015-04-09

    We present a general approach in 1H-detected 13C solid-state NMR (SSNMR) for side-chain signal assignments of 10-50 nmol quantities of proteins using a combination of a high magnetic field, ultra-fast magic-angle spinning (MAS) at ~80 kHz, and stereo-array-isotope-labeled (SAIL) proteins [Kainosho M. et al., Nature 440, 52–57, 2006]. First, we demonstrate that 1H indirect detection improves the sensitivity and resolution of 13C SSNMR of SAIL proteins for side-chain assignments in the ultra-fast MAS condition. 1H-detected SSNMR was performed for micro-crystalline ubiquitin (~55 nmol or ~0.5mg) that was SAIL-labeled at seven isoleucine (Ile) residues. Sensitivity was dramatically improved by 1H-detected 2D 1H/13C SSNMR by factors of 5.4-9.7 and 2.1-5.0, respectively, over 13C-detected 2D 1H/13C SSNMR and 1D 13C CPMAS, demonstrating that 2D 1H-detected SSNMR offers not only additional resolution but also sensitivity advantage over 1D 13C detection for the first time. High 1H resolution for the SAIL-labeled side-chain residues offered reasonable resolution even in the 2D data. A 1H-detected 3D 13C/13C/1H experiment on SAIL-ubiquitin provided nearly complete 1H and 13C assignments for seven Ile residues only within ~2.5 h. The results demonstrate the feasibility of side-chain signal assignment in this approach for as little as 10 nmol of a protein sample within ~3 days. The approach is likely applicable to a variety of proteins of biological interest without any requirements of highly efficient protein expression systems.

  2. Nano-mole scale side-chain signal assignment by 1H-detected protein solid-state NMR by ultra-fast magic-angle spinning and stereo-array isotope labeling.

    Directory of Open Access Journals (Sweden)

    Songlin Wang

    Full Text Available We present a general approach in 1H-detected 13C solid-state NMR (SSNMR for side-chain signal assignments of 10-50 nmol quantities of proteins using a combination of a high magnetic field, ultra-fast magic-angle spinning (MAS at ~80 kHz, and stereo-array-isotope-labeled (SAIL proteins [Kainosho M. et al., Nature 440, 52-57, 2006]. First, we demonstrate that 1H indirect detection improves the sensitivity and resolution of 13C SSNMR of SAIL proteins for side-chain assignments in the ultra-fast MAS condition. 1H-detected SSNMR was performed for micro-crystalline ubiquitin (~55 nmol or ~0.5mg that was SAIL-labeled at seven isoleucine (Ile residues. Sensitivity was dramatically improved by 1H-detected 2D 1H/13C SSNMR by factors of 5.4-9.7 and 2.1-5.0, respectively, over 13C-detected 2D 1H/13C SSNMR and 1D 13C CPMAS, demonstrating that 2D 1H-detected SSNMR offers not only additional resolution but also sensitivity advantage over 1D 13C detection for the first time. High 1H resolution for the SAIL-labeled side-chain residues offered reasonable resolution even in the 2D data. A 1H-detected 3D 13C/13C/1H experiment on SAIL-ubiquitin provided nearly complete 1H and 13C assignments for seven Ile residues only within ~2.5 h. The results demonstrate the feasibility of side-chain signal assignment in this approach for as little as 10 nmol of a protein sample within ~3 days. The approach is likely applicable to a variety of proteins of biological interest without any requirements of highly efficient protein expression systems.

  3. Hepatic artery injection of {sup 131}I-labelled metuximab combined with chemoembolization for intermediate hepatocellular carcinoma: a prospective nonrandomized study

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Lu; Yang, Ye-Fa; Ge, Nai-Jian; Shen, Shu-Qun; Liang, Jun [Second Military Medical University, The First Department of Interventional Radiology, Eastern Hepatobiliary Surgery Hospital, Shanghai (China); Wang, Yi [Second Military Medical University, The Second Department of Hepatic Surgery, Eastern Hepatobiliary Surgery Hospital, Shanghai (China); Zhou, Wei-Ping [Second Military Medical University, The Third Department of Hepatic Surgery, Eastern Hepatobiliary Surgery Hospital, Shanghai (China); Shen, Feng; Wu, Meng-Chao [Second Military Medical University, Eastern Hepatobiliary Surgery Hospital, Shanghai (China)

    2012-08-15

    Hepatocellular carcinoma (HCC) is the fifth and seventh most common cause of cancer in men and women, respectively. Transcatheter arterial chemoembolization (TACE) is the standardized therapy for the intermediate stage of HCC. However, the 3-year overall survival remains low (<30 %) in these patients. Thus, there is a critical need for the development of treatment modalities to improve the survival rate. This study aimed to evaluate whether the combination of {sup 131}I-metuximab with chemoembolization could improve treatment efficiency. Between January 2009 and January 2010, a prospective two-arm nonrandomized study was performed in patients with intermediate HCC. Of 138 patients, 68 (combination therapy group) received 132 courses of intraarterial {sup 131}I-metuximab injections combined with chemoembolization (mean 1.94 per patient, median 2, range 1-2), followed by 152 sessions of TACE (mean 2.24 per patient, median 2, range 0-4). The remaining 70 patients (monotherapy group) received 296 sessions of TACE (mean 4.23 per patient, median 4, range 1-7). The overall median survival times for the combination therapy group and the group treated only with TACE were 26.7 months (95 % CI 20.7-31.3 months) and 20.6 months (95 % CI 15.3-24.7 months), respectively. The combination therapy group had a significantly higher survival rate than the TACE-only group (P = 0.038). Age {>=}65 years, serum albumin {<=}35 g/l, and treatment category (combination therapy or TACE only) were independent prognostic factors for survival according to multivariate analysis. The combination of {sup 131}I-metuximab and chemoembolization extended survival in patients with intermediate HCC compared with TACE only, and was well tolerated by patients with Child-Pugh class A or B disease. This combination seems to be a promising treatment modality for patients with intermediate HCC. (orig.)

  4. Spin foams without spins

    Science.gov (United States)

    Hnybida, Jeff

    2016-10-01

    We formulate the spin foam representation of discrete SU(2) gauge theory as a product of vertex amplitudes each of which is the spin network generating function of the boundary graph dual to the vertex. In doing so the sums over spins have been carried out. The boundary data of each n-valent node is explicitly reduced with respect to the local gauge invariance and has a manifest geometrical interpretation as a framed polyhedron of fixed total area. Ultimately, sums over spins are traded for contour integrals over simple poles and recoupling theory is avoided using generating functions.

  5. A spin label study of perturbation effects of N-(1-methyldodecyl)-N, N, N-trimethylammonium bromide and N-(1-methyldodecyl)-N, N-dimethylamine oxide on model membranes prepared from Escherichia coli-isolated lipids.

    Science.gov (United States)

    Sersen, F; Leitmanová, A; Devínsky, F; Lacko, I; Balgavý, P

    1989-04-01

    Interaction of bactericidal surfactants N-(1-methyldodecyl)-N, N, N-trimethylammonium bromide (2-ATDBr) and N-(1-methyldodecyl)-N, N-dimethylamine oxide (2-ATDNO) with phospholipid membranes prepared from Escherichia coli -- isolated lipids was studied by ESR spectroscopy using m-doxyl stearic acid (m-DSA, m = 5, 12, 16) and N-cetyl-N, N-dimethyl-N-tempoylammonium bromide spin labels located in different membrane depths. 2-ATDBr was found to be a more potent membrane perturbant than 2-ATDNO both at equal membrane and sample concentrations; this is in compliance with the respective antimicrobial activities of these agents. Using the statistical model of hydrocarbon chains in lipid bilayers, the probabilities of the formation of gauche conformations and the effective energy differences between the trans and gauche conformations were calculated from m-DSA order parameters for two different bilayer regions. Based on these parameters, a molecular model of the location of surfactant molecules in bilayer has been formulated. It has been suggested that at low concentrations the surfactant molecules are located in structural defects between lipid clusters in the bilayer. After filling up these defects, the surfactant molecules penetrate into the clusters between lipid molecules, expand the bilayer laterally and increase the amount of gauche conformations in the hydrocarbon chains in the hydrophobic core of the bilayer.

  6. Operator Spin Foam Models

    CERN Document Server

    Bahr, Benjamin; Kamiński, Wojciech; Kisielowski, Marcin; Lewandowski, Jerzy

    2010-01-01

    The goal of this paper is to introduce a systematic approach to spin foams. We define operator spin foams, that is foams labelled by group representations and operators, as the main tool. An equivalence relation we impose in the set of the operator spin foams allows to split the faces and the edges of the foams. The consistency with that relation requires introduction of the (familiar for the BF theory) face amplitude. The operator spin foam models are defined quite generally. Imposing a maximal symmetry leads to a family we call natural operator spin foam models. This symmetry, combined with demanding consistency with splitting the edges, determines a complete characterization of a general natural model. It can be obtained by applying arbitrary (quantum) constraints on an arbitrary BF spin foam model. In particular, imposing suitable constraints on Spin(4) BF spin foam model is exactly the way we tend to view 4d quantum gravity, starting with the BC model and continuing with the EPRL or FK models. That makes...

  7. Hemoptysis and pulmonary artery agenesis: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Majano, V.; Sobti, P.

    1985-08-01

    The combination of a pulmonary scintigram using radioactively labeled albumin macroaggregates (MAA) and a study of the circulation in the bronchial artery was performed in one patient. This noninvasive methodology showed that there was increased circulation to the vascular territory of the lung in which the pulmonary artery was missing. This could have resulted from abnormal communications between the bronchial artery and the pulmonary vessels or an increased blood supply to the right lung from bronchial arteries arising from the aorta. The absence of pulmonary circulation in the right lung was proved by the absence of radioactivity in the right lung after an intravenous injection of labeled albumin MAA.

  8. Nutrition Labeling

    DEFF Research Database (Denmark)

    Grunert, Klaus G

    2013-01-01

    Nutrition labeling refers to the provision of information on a food product’s nutritional content on the package label. It can serve both public health and commercial purposes. From a public health perspective, the aim of nutrition labeling is to provide information that can enable consumers...... choices, but the nutritional content of food products may not always be clear to consumers, nutrition labeling can contribute to making the nutritional content more transparent, thus reducing the frequency of unhealthy choices. Nutrition labeling is sometimes also motivated by consumers’ right to know......, implying that the availability of information on the nutritional content on food products is of value in itself, no matter how this impacts consumer choices. Another argument for nutrition labeling is that making information about nutritional content transparent will lead to healthier products, partly...

  9. Spin Foams Without Spins

    CERN Document Server

    Hnybida, Jeff

    2015-01-01

    We formulate the spin foam representation of discrete SU(2) gauge theory as a product of vertex amplitudes each of which is the spin network generating function of the boundary graph dual to the vertex. Thus the sums over spins have been carried out. We focus on the character expansion of Yang-Mills theory which is an approximate heat kernel regularization of BF theory. The boundary data of each $n$-valent node is an element of the Grassmannian Gr(2,$n$) which carries a coherent representation of U($n$) and a geometrical interpretation as a framed polyhedron of fixed total area. Ultimately, sums over spins are traded for contour integrals over simple poles and recoupling theory is avoided using generating functions.

  10. Food Labels

    Science.gov (United States)

    ... because they don't raise cholesterol levels like saturated fats and trans fats do. Both saturated and trans ... at room temperature (picture them clogging your arteries). Saturated fats usually come from animal products like cheese, meats, ...

  11. Spin current

    CERN Document Server

    Valenzuela, Sergio O; Saitoh, Eiji; Kimura, Takashi

    2012-01-01

    In a new branch of physics and technology called spin-electronics or spintronics, the flow of electrical charge (usual current) as well as the flow of electron spin, the so-called 'spin current', are manipulated and controlled together. This book provides an introduction and guide to the new physics and application of spin current.

  12. Pulsed ELDOR in spin-labeled polypeptides

    Science.gov (United States)

    Milov, Alexander D.; Maryasov, Alexander G.; Tsvetkov, Yuri D.; Raap, Jan

    1999-04-01

    The pulsed electron-electron double-resonance (PELDOR) technique was applied to obtain information about the structure of the synthetic polypeptide-biradical in a frozen glassy solution. From the concentration dependence of the PELDOR signal, the effects of intermolecular and intramolecular interactions were separated. It was found that the intramolecular dipole-dipole interactions in the biradical peptide led to the modulation effects in the PELDOR signal decay. This may be attributed to the existence of a conformational population having a distance between the two unpaired electrons of ˜20 Å with a distribution of (˜2 Å). Its fraction is estimated as about 25%.

  13. Acute arterial occlusion - kidney

    Science.gov (United States)

    Acute renal arterial thrombosis; Renal artery embolism; Acute renal artery occlusion; Embolism - renal artery ... kidney can often result in permanent kidney failure. Acute arterial occlusion of the renal artery can occur after injury or trauma to ...

  14. Rotational-resonance distance measurements in multi-spin systems.

    Science.gov (United States)

    Verhoeven, Aswin; Williamson, Philip T F; Zimmermann, Herbert; Ernst, Matthias; Meier, Beat H

    2004-06-01

    It is demonstrated that internuclear distances can be evaluated from rotational-resonance (RR) experiments in uniformly (13)C-labelled compounds. The errors in the obtained distances are less than 10% without the need to know any parameters of the spin system except the isotropic chemical shifts of all spins. We describe the multi-spin system with a simple fictitious spin-1/2 model. The influence of the couplings to the passive spins (J and dipolar coupling) is described by an empirical constant offset from the rotational-resonance condition. Using simulated data for a three-spin system, we show that the two-spin model describes the rotational-resonance transfer curves well as long as none of the passive spins is close to a rotational-resonance condition with one of the active spins. The usability of the two-spin model is demonstrated experimentally using a sample of acetylcholine perchlorate with labelling schemes of various levels of complexity. Doubly-, triply-, and fully labelled compounds lead to strongly varying RR polarization-transfer curves but the evaluated distances using the two-spin model are identical within the expected error limits and coincide with the distance from the X-ray structure. Rotational-resonance distance measurements in fully labelled compounds allow, in particular, the measurement of weak couplings in the presence of strong couplings.

  15. Introduction to Pesticide Labels

    Science.gov (United States)

    Pesticide product labels provide critical information about how to safely and legally handle and use pesticide products. Unlike most other types of product labels, pesticide labels are legally enforceable. Learn about pesticide product labels.

  16. Reduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla.

    Science.gov (United States)

    Wang, Jiongjiong; Li, Lin; Roc, Anne C; Alsop, David C; Tang, Kathy; Butler, Norman S; Schnall, Mitchell D; Detre, John A

    2004-01-01

    Arterial spin labeling (ASL) perfusion contrast is not based on susceptibility effects and can therefore be used to study brain function in regions of high static inhomogeneity. As a proof of concept, single-shot spin-echo echo-planar imaging (EPI) acquisition was carried out with a multislice continuous ASL (CASL) method at 1.5T. A bilateral finger tapping paradigm was used in the presence of an exogenously induced susceptibility artifact over left motor cortex. The spin-echo CASL technique was compared with a regular gradient-echo EPI sequence with the same slice thickness, as well as other imaging methods using thin slices and spin-echo acquisitions. The results demonstrate improved functional sensitivity and efficiency of the spin-echo CASL approach as compared with gradient-echo EPI techniques, and a trend of improved sensitivity as compared with spin-echo EPI approach in the brain regions affected by the susceptibility artifact. ASL images, either with or without subtraction of the control, provide a robust alternative to blood oxygenation level dependant (BOLD) methods for activation imaging in regions of high static field inhomogeneity.

  17. On Online Labeling with Polynomially Many Labels

    DEFF Research Database (Denmark)

    Babka, Martin; Bulánek, Jan; Cunat, Vladimír

    2012-01-01

    In the online labeling problem with parameters n and m we are presented with a sequence of nkeys from a totally ordered universe U and must assign each arriving key a label from the label set {1,2,…,m} so that the order of labels (strictly) respects the ordering on U. As new keys arrive it may be...

  18. A multimodal imaging study on spatial pattern of cerebral perfusion change caused by symptomatic unilateral carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Jian-rui LI

    2015-03-01

    Full Text Available Objective To investigate the spatial pattern of cerebral perfusion decrease resulting from symptomatic unilateral carotid artery stenosis and to assess the relationship between degrees of stenosis and cerebral blood flow (CBF.  Methods CT angiography (CTA and arterial spin labeling (ASL MRI cerebral perfusion were performed in 22 patients with symptomatic unilateral carotid artery stenosis. Diagnosis of carotid artery stenosis and measurement of stenosis degrees was performed by using CTA; cerebral perfusion was determined by ASL. Voxel-based analysis (VBA were applied to observe perfusion changes in patients with mild stenosis and moderate to severe stenosis, and spatial pattern of cerebral perfusion changes caused by carotid artery stenosis. Analysis based on region of interest (ROI was used to explore the relationship between degrees of stenosis and CBF. Results Twenty-two patients with symptomatic unilateral carotid artery stenosis (13 in the left side and 9 in the right included 13 cases with mild stenosis and 9 cases with moderate to severe stenosis. Compared to those with mild stenosis, patients with moderate to severe stenosis showed reduced CBF in bilateral (especially in the affected side parietal lobes (t = - 2.382, P = 0.014, frontal lobes (t = - 2.354, P = 0.015 and centrum semiovale (t = - 2.283, P = 0.017, and was basically located in bilateral cerebral watershed area. Furthermore, perfusion in these areas was negatively correlated with the degree of stenosis (r = - 0.479, P = 0.024.  Conclusions Symptomatic unilateral carotid artery stenosis may result in cerebral perfusion decreases in bilateral (particularly in the affected side watershed area and cerebral blood flow is negatively correlated with the degree of stenosis. DOI: 10.3969/j.issn.1672-6731.2015.02.006

  19. Spin foams

    CERN Document Server

    Engle, Jonathan

    2013-01-01

    The spin foam framework provides a way to define the dynamics of canonical loop quantum gravity in a spacetime covariant way, by using a path integral over histories of quantum states which can be interpreted as `quantum space-times'. This chapter provides a basic introduction to spin foams aimed principally at beginning graduate students and, where possible, at broader audiences.

  20. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  1. Positron emission tomography/magnetic resonance hybrid scanner imaging of cerebral blood flow using 15O-water positron emission tomography and arterial spin labeling magnetic resonance imaging in newborn piglets

    DEFF Research Database (Denmark)

    Andersen, Julie B; Henning, William S; Lindberg, Ulrich;

    2015-01-01

    Abnormality in cerebral blood flow (CBF) distribution can lead to hypoxic-ischemic cerebral damage in newborn infants. The aim of the study was to investigate minimally invasive approaches to measure CBF by comparing simultaneous (15)O-water positron emission tomography (PET) and single TI pulsed...

  2. Application of interictal arterial spin labeling MR perfusion in intractable mesial temporal lobe epilepsy%动脉自旋标记在难治性颞叶内侧癫痫发作间期的应用

    Institute of Scientific and Technical Information of China (English)

    孙泓泓; 吕长磊; 白芝兰; 张晓娜; 师莉芳

    2012-01-01

    Objective To determine whether pulsed ASL(PASL) MR] using flow-sensitive alternating inversion recovery) FAIR) could be a useful clinical tool to detect intcrictal temporal hypopcrfusion in mesial temporal lobe cpilcpsy(TLEl) ,thcn on the base of changes of cerebral blood flow(CBF) to determine the seizure focus. Methods 15 normal controls and 15 patients were studied by using a FAIR pcrfusion mode to measure the CBF of mesial temporal lobe. According to the vidco-clcctrocnccphalography ( VEEG) findings, the origin sides of seizure were obtained in all patients. Results Pcrfusion in control participants was ( 167. 95 ± 15. 30) mL/( 100 g · min) on the right and (169.64 ± 13.24) mL/( 100 g · min) on the left. In patients, mesial temporal lobe pcrfusion was (158.42 ± 9.09) mL/(100 g- min) on the ipsilatcral (affected) side and (170. 11±7. 67) mL/(100 g · min) on the contralatcral (unaffected) side. The blood flow measurements were significantly different in ipsilatcral versus contralatcral sides in patients. In control participants, the mean absolute asymmetry index was 2. 49 ± 2. 09. For the patients, mean absolute asymmetry index was 7. 20 ± 4. 21. The difference was statistically significant P = 0. 001 ). The coefficient of agreement for detecting the asymmetry with FAIR and with vidco-EEG latcralization was 80%. Conclusion MR pcrfusion imaging based on the FAIR technique is capable of detecting intcrictal hypopcrfusion of mesial temporal lobe in patients with medically refractory temporal lobe epilepsy and provides complementary information to tests that assess structure.%目的 明确流动敏感交互反转恢复模式(FAIR)的脉冲式动脉自旋标记(PASL)能否检测出发作间期颞叶内侧的低灌注,根据脑血流灌注变化确定致痫灶位置.方法 15例经过视频脑电图(VEEG)确诊的颞叶癫痫(TLE)病人和15例正常对照者行FAIR测量感兴趣区脑血流量(CBF)并计算相关数值.结果 对照组左、右颞叶内侧灌注分别是(169.64±13.24) mL/(100 g·min)、(167.95±15.30) mL/(100 g·min).病例组致痫灶同侧与对侧颞叶内侧灌注分别是(158.42±9.09) mL/(100 g·min)、(170.11±7.67) mL/(100 g·min),两侧颞叶内侧血流量明显不同.对照组和病例组颞叶内侧灌注的不对称指数分别为2.49±2.09、7.20±4.21.虽然对照组颞叶内侧CBF也存在不对称性,病例组颞叶内侧CBF不对称指数(AI)明显大于对照组,AI差别存在统计学差异(P=0.001).FAIR和VEEG对致痫灶定侧一致率达80%.结论 FAIR 灌注成像可以检测出难治性TLE病人发作间期颞叶内侧CBF灌注减低,是对结构评估的有益补充.

  3. Coronary artery fistula

    Science.gov (United States)

    Congenital heart defect - coronary artery fistula; Birth defect heart - coronary artery fistula ... A coronary artery fistula is often congenital, meaning that it is present at birth. It generally occurs when one of the coronary arteries ...

  4. TOPICAL REVIEW: Spin current, spin accumulation and spin Hall effect

    Directory of Open Access Journals (Sweden)

    Saburo Takahashi and Sadamichi Maekawa

    2008-01-01

    Full Text Available Nonlocal spin transport in nanostructured devices with ferromagnetic injector (F1 and detector (F2 electrodes connected to a normal conductor (N is studied. We reveal how the spin transport depends on interface resistance, electrode resistance, spin polarization and spin diffusion length, and obtain the conditions for efficient spin injection, spin accumulation and spin current in the device. It is demonstrated that the spin Hall effect is caused by spin–orbit scattering in nonmagnetic conductors and gives rise to the conversion between spin and charge currents in a nonlocal device. A method of evaluating spin–orbit coupling in nonmagnetic metals is proposed.

  5. Spin electronics

    CERN Document Server

    Buhrman, Robert; Daughton, James; Molnár, Stephan; Roukes, Michael

    2004-01-01

    This report is a comparative review of spin electronics ("spintronics") research and development activities in the United States, Japan, and Western Europe conducted by a panel of leading U.S. experts in the field. It covers materials, fabrication and characterization of magnetic nanostructures, magnetism and spin control in magnetic nanostructures, magneto-optical properties of semiconductors, and magnetoelectronics and devices. The panel's conclusions are based on a literature review and a series of site visits to leading spin electronics research centers in Japan and Western Europe. The panel found that Japan is clearly the world leader in new material synthesis and characterization; it is also a leader in magneto-optical properties of semiconductor devices. Europe is strong in theory pertaining to spin electronics, including injection device structures such as tunneling devices, and band structure predictions of materials properties, and in development of magnetic semiconductors and semiconductor heterost...

  6. 13 C solid-state NMR study of the 13 C-labeled peptide, (E)8 GGLGGQGAG(A)6 GGAGQGGYGG as a model for the local structure of Nephila clavipes dragline silk (MaSp1) before and after spinning.

    Science.gov (United States)

    Yazawa, Koji; Yamaguchi, Erika; Knight, David; Asakura, Tetsuo

    2012-06-01

    We prepared the water soluble model peptide, (E)(8) GGLGGQGAG(A)(6) GGAGQGGYGG, to throw light on the local structure of spidroin 1 (MaSpl) protein in spider dragline silk of Nephila clavipes before and after spinning. Solution (13) C NMR showed that the conformation of the peptide in aqueous solution was essentially random coil. Solid-state NMR was used to follow conformation-dependent (13) C chemical shifts in (13) C selectively labeled versions of the peptide. The peptide lyophilized from an aqueous solution at neutral pH (hereafter referred to as "without acid treatment)"was used to mimic the state of the spidroin stored in the spider's silk gland while the peptide precipitated from the acidic solution ("with acid treatment") was used to simulate the role of acid treatment in inducing conformation change in the natural spinning process. In without acid treatment, the fraction of random coil conformation was lowest in the N-terminal region (residues 15-18) when compared with the C-terminus. The conformational change produced by the acid treatment occurred in the sequence, G(15) AG(A)(6) GGAG(27), interposed between pairs of Gly residues pairs, Gly(12,13), and Gly(29,30). The acid treated peptide showed a remarkable decrease in the fraction of random coil conformation from A(20) to A(23) in the poly-Ala region when compared with the peptide without acid treatment. These observations taken together suggest that the peptide can be used as a model for studying the localization of the conformation change in spider silk fibroin in the natural spinning and the role of acid treatment in this process.

  7. Imaging of early carotid artery atherosclerotic lesions with {sup 111}In-labeled polyclonalhuman IgG (HIG); Darstellung frueher atherosklerotischer Laesionen der A. carotis mit {sup 111}In-markiertem polyklonalen humanem IgG (HIG)

    Energy Technology Data Exchange (ETDEWEB)

    Kritz, H. [Wilhelm-Auerswald-Atherioskleroseforschungsgruppe (ASF), Wien (Austria); Rodrigues, M.; Sinzinger, H. [Universitaetsklinik fuer Nuklearmedizin, Wien (Austria)]|[Wilhelm-Auerswald-Atherioskleroseforschungsgruppe (ASF), Wien (Austria)

    1997-12-01

    To assess the value of scintigraphy with {sup 111}In-HIG for diagnosis and evaluation of the stage and the clinical extent of carotid artery disease in humans a prospective clinical comparative trial of scintigraphy vs. sonography was performed. 58 patients (38 male, 20 female; mean age 60{+-}7 years) with hyperlipidemia and ultrasonographically detectable carotid artery lesions were studied. After i.v. injection of 18.5 MBq {sup 111}In-HIG, anterior scintigraphic images of the neck were acquired. Real time two-dimensional B-mode ultrasonography of the left and the right carotid arteries was performed. {sup 111}In-HIG-scintigraphy as compared to the morphological gold standard (ultrasonography) had a sensitivity of 70-73%, specificity of 33-41% and a positive predictive value of 77-82% for detecting carotid atherosclerotic lesions. There was, however, no significant correlation between scintigraphy and ultrasonography. However, the data provide evidence that the two imaging techniques are visualizing different aspects of atherogenesis. On the one hand a functional one reflecting the activity of the disease ({sup 111}In-HIG) and on the other hand the morphological one resembling the extent of the disease (ultrasonography). (orig.) [Deutsch] Zur Erfassung morphologischer und funktioneller Veraenderungen bei fruehen atherosklerotischen Gefaessveraenderungen wurde in der vorliegenden prospektiven Vergleichsstudie die Wertigkeit der Szintigraphie mit {sup 111}In-markiertem humanem Immunglobulin G ({sup 111}In-HIG) im Vergleich zur hochaufloesenden Sonographie verglichen. 58 Patienten (38 Maenner, 20 Frauen; mittleres Alter 60{+-}7 Jahre) mit einer Dyslipoproteinaemie und sonographisch nachgewiesenen atherosklerotischen Laesionen der A. carotis wurden untersucht. Nach i.v. Applikation von 18,5 MBq {sup 111}In-HIG wurden a.p. Szintigramme der Halsregion angefertigt. Weiter wurde eine zweidimensionale Realtime-B-Mode-Sonographie der linken und rechten Arteria carotis

  8. Classical gravitational spin-spin interaction

    OpenAIRE

    Bonnor, W. B.

    2002-01-01

    I obtain an exact, axially symmetric, stationary solution of Einstein's equations for two massless spinning particles. The term representing the spin-spin interaction agrees with recently published approximate work. The spin-spin force appears to be proportional to the inverse fourth power of the coordinate distance between the particles.

  9. Spin-Orbit induced semiconductor spin guides

    OpenAIRE

    Valin-Rodriguez, Manuel; Puente, Antonio; Serra, Llorens

    2002-01-01

    The tunability of the Rashba spin-orbit coupling allows to build semiconductor heterostructures with space modulated coupling intensities. We show that a wire-shaped spin-orbit modulation in a quantum well can support propagating electronic states inside the wire only for a certain spin orientation and, therefore, it acts as an effective spin transmission guide for this particular spin orientation.

  10. Ivabradine: A Review of Labeled and Off-Label Uses.

    Science.gov (United States)

    Oliphant, Carrie S; Owens, Ryan E; Bolorunduro, Oluwaseyi B; Jha, Sunil K

    2016-10-01

    Ivabradine is a unique medication recently approved in the USA for the treatment of select heart failure patients. It was first approved for use in several countries around the world over a decade ago as an anti-anginal agent, with subsequent approval for use in heart failure patients. Since ivabradine has selective activity blocking the I f currents in the sinus node, it can reduce heart rate without appreciable effects on blood pressure. Given this heart-rate-specific effect, it has been investigated in many off-label indications as an alternative to traditional heart-rate-reducing medications such as beta blockers and calcium channel blockers. We conducted searches of PubMed and Google Scholar for ivabradine, heart failure, HFrEF, HFpEF, angina, coronary artery disease, inappropriate sinus tachycardia, postural orthostatic hypotension, coronary computed tomography angiography and atrial fibrillation. We reviewed and included studies, case reports, and case series published between 1980 and June 2016 if they provided information relevant to the practicing clinician. In many cases, larger clinical trials are needed to solidify the benefit of ivabradine, although studies indicate benefit in most therapeutic areas explored to date. The purpose of this paper is to review the current labeled and off-label uses of ivabradine, with a focus on clinical trial data.

  11. A spin cell for spin current.

    Science.gov (United States)

    Sun, Qing-feng; Guo, Hong; Wang, Jian

    2003-06-27

    We propose and investigate a spin-cell device which provides the necessary spin-motive force to drive a spin current for future spintronic circuits. Our spin cell has four basic characteristics: (i) it has two poles so that a spin current flows in from one pole and out from the other pole, and in this way a complete spin circuit can be established; (ii) it has a source of energy to drive the spin current; (iii) it maintains spin coherence so that a sizable spin current can be delivered; (iv) it drives a spin current without a charge current. The proposed spin cell for spin current should be realizable using technologies presently available.

  12. Spin squeezing in nonlinear spin coherent states

    OpenAIRE

    Wang, Xiaoguang

    2001-01-01

    We introduce the nonlinear spin coherent state via its ladder operator formalism and propose a type of nonlinear spin coherent state by the nonlinear time evolution of spin coherent states. By a new version of spectroscopic squeezing criteria we study the spin squeezing in both the spin coherent state and nonlinear spin coherent state. The results show that the spin coherent state is not squeezed in the x, y, and z directions, and the nonlinear spin coherent state may be squeezed in the x and...

  13. Electron spin resonance studies on reduction process of nitroxyl spin radicals used in molecular imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dhas, M. Kumara; Benial, A. Milton Franklin, E-mail: miltonfranklin@yahoo.com [Department of Physics, NMSSVN College, Nagamalai, Madurai-625019, Tamilnadu (India); Jawahar, A. [Department of Chemistry, NMSSVN College, Nagamalai, Madurai-625019, Tamilnadu (India)

    2014-04-24

    The Electron spin resonance studies on the reduction process of nitroxyl spin probes were carried out for 1mM {sup 14}N labeled nitroxyl radicals in pure water and 1 mM concentration of ascorbic acid as a function of time. The electron spin resonance parameters such as signal intensity ratio, line width, g-value, hyperfine coupling constant and rotational correlation time were determined. The half life time was estimated for 1mM {sup 14}N labeled nitroxyl radicals in 1 mM concentration of ascorbic acid. The ESR study reveals that the TEMPONE has narrowest line width and fast tumbling motion compared with TEMPO and TEMPOL. From the results, TEMPONE has long half life time and high stability compared with TEMPO and TEMPOL radical. Therefore, this study reveals that the TEMPONE radical can act as a good redox sensitive spin probe for molecular imaging.

  14. Cavity spin optodynamics

    CERN Document Server

    Brahms, N

    2010-01-01

    The dynamics of a large quantum spin coupled parametrically to an optical resonator is treated in analogy with the motion of a cantilever in cavity optomechanics. New spin optodynamic phenonmena are predicted, such as cavity-spin bistability, optodynamic spin-precession frequency shifts, coherent amplification and damping of spin, and the spin optodynamic squeezing of light.

  15. Peripheral arterial line (image)

    Science.gov (United States)

    A peripheral arterial line is a small, short plastic catheter placed through the skin into an artery of the arm or leg. The purpose of a peripheral arterial line is to allow continuous monitoring of ...

  16. MR imaging findings of renal infarction induced by renal artery

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun Woo; Kim, Suck; Kim, Yong Woo; Hu, Jin Sam; Choi, Sang Yoel; Moon, Tae Yong; Lee, Suck Hong; Kim, Byung Su; Lee, Chang Hun [Pusan National Univ., Pusan (Korea, Repulic of). Coll. of Medicine

    1998-02-01

    To assess the usefulness of diffusion-weighted imaging (DWI) in evaluating serial parenchymal changes in renal infarction induced by renal artery ligation, by comparing this with the conventional spin echo technique and correlating the results with the histopathological findings. In 22 rabbits, renal infarction was induced by ligation of the renal artery. Spin-echo T1-weighted imaging (T1WI), turbo spin-echo (TSE) T2-weighted imaging (T2WI), and DWI were performed, using a 1.5-T superconductive unit, at 30 minutes, 1 hour, 2,3,6, 12 and 24 hours, and 2, 3, 7 and 20 days after left renal artery ligation. Changes in signal intensity on T1WI, T2WI, and DWI were correlated with histopathologic findings. Diffusion-weighted imaging is useful for the detection of hyperacute renal infarction, and the apparent diffusion coefficient may provide additional information concerning its evolution. (author). 21 refs., 9 figs.

  17. Semiotic labelled deductive systems

    Energy Technology Data Exchange (ETDEWEB)

    Nossum, R.T. [Imperial College of Science, Technology and Medicine, London (United Kingdom)

    1996-12-31

    We review the class of Semiotic Models put forward by Pospelov, as well as the Labelled Deductive Systems developed by Gabbay, and construct an embedding of Semiotic Models into Labelled Deductive Systems.

  18. Mental Labels and Tattoos

    Science.gov (United States)

    Hyatt, I. Ralph

    1977-01-01

    Discusses the ease with which mental labels become imprinted in our system, six basic axioms for maintaining negative mental tattoos, and psychological processes for eliminating mental tattoos and labels. (RK)

  19. Pesticide Product Label System

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Pesticide Product Label System (PPLS) provides a collection of pesticide product labels (Adobe PDF format) that have been approved by EPA under Section 3 of the...

  20. Mean arterial pressure change associated with cerebral blood flow in healthy older adults.

    Science.gov (United States)

    Deverdun, Jeremy; Akbaraly, Tasnime N; Charroud, Celine; Abdennour, Meriem; Brickman, Adam M; Chemouny, Stephane; Steffener, Jason; Portet, Florence; Bonafe, Alain; Stern, Yaakov; Ritchie, Karen; Molino, François; Le Bars, Emmanuelle; Menjot de Champfleur, Nicolas

    2016-10-01

    We investigate over a 12-year period the association between regional cerebral blood flow (CBF) and cardiovascular risk factors in a prospective cohort of healthy older adults (81.96 ± 3.82 year-old) from the Cognitive REServe and Clinical ENDOphenotype (CRESCENDO) study. Cardiovascular risk factors were measured over 12 years, and gray matter CBF was measured at the end of the study from high-resolution magnetic resonance imaging using arterial spin labeling. The association between cardiovascular risk factors, their long-term change, and CBF was assessed using multivariate linear regression models. Women were observed to have higher CBF than men (p < 0.05). Increased mean arterial pressure (MAP) over the 12-year period was correlated with a low cerebral blood flow (p < 0.05, R(2) = 0.21), whereas no association was detected between CBF and MAP at the time of imaging. High levels of glycemia tended to be associated with low cerebral blood flow values (p < 0.05). Age, alcohol consumption, smoking status, body mass index, history of cardiovascular disease, and hypertension were not associated with CBF. Our main result suggests that change in MAP is the most significant predictor of future CBF in older adults.

  1. Labeling Schemes with Queries

    OpenAIRE

    2006-01-01

    We study the question of ``how robust are the known lower bounds of labeling schemes when one increases the number of consulted labels''. Let $f$ be a function on pairs of vertices. An $f$-labeling scheme for a family of graphs $\\cF$ labels the vertices of all graphs in $\\cF$ such that for every graph $G\\in\\cF$ and every two vertices $u,v\\in G$, the value $f(u,v)$ can be inferred by merely inspecting the labels of $u$ and $v$. This paper introduces a natural generalization: the notion of $f$-...

  2. Relativistic Spin Operators

    Institute of Scientific and Technical Information of China (English)

    ZHANG Peng-Fei; RUAN Tu-Nan

    2001-01-01

    A systematic theory on the appropriate spin operators for the relativistic states is developed. For a massive relativistic particle with arbitrary nonzero spin, the spin operator should be replaced with the relativistic one, which is called in this paper as moving spin. Further the concept of moving spin is discussed in the quantum field theory. A new is constructed. It is shown that, in virtue of the two operators, problems in quantum field concerned spin can be neatly settled.

  3. Succesful labelling schemes

    DEFF Research Database (Denmark)

    Juhl, Hans Jørn; Stacey, Julia

    2001-01-01

    It is usual practice to evaluate the success of a labelling scheme by looking at the awareness percentage, but in many cases this is not sufficient. The awareness percentage gives no indication of which of the consumer segments that are aware of and use labelling schemes and which do not. In the ......It is usual practice to evaluate the success of a labelling scheme by looking at the awareness percentage, but in many cases this is not sufficient. The awareness percentage gives no indication of which of the consumer segments that are aware of and use labelling schemes and which do not....... In the spring of 2001 MAPP carried out an extensive consumer study with special emphasis on the Nordic environmentally friendly label 'the swan'. The purpose was to find out how much consumers actually know and use various labelling schemes. 869 households were contacted and asked to fill in a questionnaire...... it into consideration when I go shopping. The respondent was asked to pick the most suitable answer, which described her use of each label. 29% - also called 'the labelling blind' - responded that they basically only knew the recycling label and the Government controlled organic label 'Ø-mærket'. Another segment of 6...

  4. Magnetic Nanostructures Spin Dynamics and Spin Transport

    CERN Document Server

    Farle, Michael

    2013-01-01

    Nanomagnetism and spintronics is a rapidly expanding and increasingly important field of research with many applications already on the market and many more to be expected in the near future. This field started in the mid-1980s with the discovery of the GMR effect, recently awarded with the Nobel prize to Albert Fert and Peter Grünberg. The present volume covers the most important and most timely aspects of magnetic heterostructures, including spin torque effects, spin injection, spin transport, spin fluctuations, proximity effects, and electrical control of spin valves. The chapters are written by internationally recognized experts in their respective fields and provide an overview of the latest status.

  5. Mesenteric artery ischemia

    Science.gov (United States)

    ... medlineplus.gov/ency/article/001156.htm Mesenteric artery ischemia To use the sharing features on this page, please enable JavaScript. Mesenteric artery ischemia occurs when there is a narrowing or blockage ...

  6. Decoherence dynamics of a single spin versus spin ensemble

    NARCIS (Netherlands)

    Dobrovitski, V.V.; Feiguin, A.E.; Awschalom, D.D.; Hanson, R.

    2008-01-01

    We study decoherence of central spins by a spin bath, focusing on the difference between measurement of a single central spin and measurement of a large number of central spins (as found in typical spin-resonance experiments). For a dilute spin bath, the single spin demonstrates Gaussian free-induct

  7. Upper limb arterial thromboembolism

    DEFF Research Database (Denmark)

    Andersen, L V; Lip, Gregory Y.H.; Lindholt, J S;

    2013-01-01

    The aim of this review is to focus on risk factors, risk-modifying drugs and prognosis for upper limb arterial thromboembolism, and the relationship between upper limb arterial thromboembolism and atrial fibrillation (AF).......The aim of this review is to focus on risk factors, risk-modifying drugs and prognosis for upper limb arterial thromboembolism, and the relationship between upper limb arterial thromboembolism and atrial fibrillation (AF)....

  8. Entangled spins and ghost-spins

    CERN Document Server

    Jatkar, Dileep P

    2016-01-01

    We study patterns of quantum entanglement in systems of spins and ghost-spins regarding them as simple quantum mechanical toy models for theories containing negative norm states. We define a single ghost-spin as in arXiv:1602.06505 [hep-th] as a 2-state spin variable with an indefinite inner product in the state space. We find that whenever the spin sector is disentangled from the ghost-spin sector (both of which could be entangled within themselves), the reduced density matrix obtained by tracing over all the ghost-spins gives rise to positive entanglement entropy for positive norm states, while negative norm states have an entanglement entropy with a negative real part and a constant imaginary part. However when the spins are entangled with the ghost-spins, there are new entanglement patterns in general. For systems where the number of ghost-spins is even, it is possible to find subsectors of the Hilbert space where positive norm states always lead to positive entanglement entropy after tracing over the gho...

  9. Magnons, Spin Current and Spin Seebeck Effect

    Science.gov (United States)

    Maekawa, Sadamichi

    2012-02-01

    When metals and semiconductors are placed in a temperature gradient, the electric voltage is generated. This mechanism to convert heat into electricity, the so-called Seebeck effect, has attracted much attention recently as the mechanism for utilizing wasted heat energy. [1]. Ferromagnetic insulators are good conductors of spin current, i.e., the flow of electron spins [2]. When they are placed in a temperature gradient, generated are magnons, spin current and the spin voltage [3], i.e., spin accumulation. Once the spin voltage is converted into the electric voltage by inverse spin Hall effect in attached metal films such as Pt, the electric voltage is obtained from heat energy [4-5]. This is called the spin Seebeck effect. Here, we present the linear-response theory of spin Seebeck effect based on the fluctuation-dissipation theorem [6-8] and discuss a variety of the devices. [4pt] [1] S. Maekawa et al, Physics of Transition Metal Oxides (Springer, 2004). [0pt] [2] S. Maekawa: Nature Materials 8, 777 (2009). [0pt] [3] Concept in Spin Electronics, eds. S. Maekawa (Oxford University Press, 2006). [0pt] [4] K. Uchida et al., Nature 455, 778 (2008). [0pt] [5] K. Uchida et al., Nature Materials 9, 894 (2010) [0pt] [6] H. Adachi et al., APL 97, 252506 (2010) and Phys. Rev. B 83, 094410 (2011). [0pt] [7] J. Ohe et al., Phys. Rev. B (2011) [0pt] [8] K. Uchida et al., Appl. Phys. Lett. 97, 104419 (2010).

  10. Spin-polarized spin excitation spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Loth, Sebastian; Lutz, Christopher P; Heinrich, Andreas J, E-mail: lothseb@us.ibm.com, E-mail: heinrich@almaden.ibm.com [IBM Research Division, Almaden Research Center, San Jose, CA 95120 (United States)

    2010-12-15

    We report on the spin dependence of elastic and inelastic electron tunneling through transition metal atoms. Mn, Fe and Cu atoms were deposited onto a monolayer of Cu{sub 2}N on Cu(100) and individually addressed with the probe tip of a scanning tunneling microscope. Electrons tunneling between the tip and the substrate exchange energy and spin angular momentum with the surface-bound magnetic atoms. The conservation of energy during the tunneling process results in a distinct onset threshold voltage above which the tunneling electrons create spin excitations in the Mn and Fe atoms. Here we show that the additional conservation of spin angular momentum leads to different cross-sections for spin excitations depending on the relative alignment of the surface spin and the spin of the tunneling electron. For this purpose, we developed a technique for measuring the same local spin with a spin-polarized and a non-spin-polarized tip by exchanging the last apex atom of the probe tip between different transition metal atoms. We derive a quantitative model describing the observed excitation cross-sections on the basis of an exchange scattering process.

  11. Purely geometric path integral for spin foams

    CERN Document Server

    Shirazi, Atousa Chaharsough

    2013-01-01

    Spin-foams are a proposal for defining the dynamics of loop quantum gravity via path integral. In order for a path integral to be at least formally equivalent to the corresponding canonical quantization, at each point in the space of histories it is important that the integrand have not only the correct phase -- a topic of recent focus in spin-foams -- but also the correct modulus, usually referred to as the measure factor. The correct measure factor descends from the Liouville measure on the reduced phase space, and its calculation is a task of canonical analysis. The covariant formulation of gravity from which spin-foams are derived is the Plebanski-Holst formulation, in which the basic variables are a Lorentz connection and a Lorentz-algebra valued two-form, called the Plebanski two-form. However, in the final spin-foam sum, one sums over only spins and intertwiners, which label eigenstates of the Plebanski two-form alone. The spin-foam sum is therefore a discretized version of a Plebanski-Holst path integ...

  12. [Upper extremity arterial diseases].

    Science.gov (United States)

    Becker, F

    2007-02-01

    Compared to lower limb arterial diseases, upper limb arterial diseases look rare, heterogeneous with various etiologies and a rather vague clinical picture, but with a negligible risk of amputation. Almost all types of arterial diseases can be present in the upper limb, but the anatomical and hemodynamic conditions particular to the upper limb often confuse the issue. Thus, atherosclerosis affects mainly the subclavian artery in its proximal segment where the potential of collateral pathway is high making the symptomatic forms not very frequent whereas the prevalence of subclavian artery stenosis or occlusion is relatively high. The clinical examination and the etiologies are discussed according to the clinical, anatomical and hemodynamic context.

  13. Quantum spin model fitting the Yule distribution of oligonucleotides in DNA

    CERN Document Server

    Minichini, C

    2004-01-01

    A quantum spin chain is identified by the labels of a vector state of a Kashiwara crystal basis. The intensity of the one-spin flip is assumed to depend from the variation of the labels. The rank ordered plot of the numerically computed, averaged in time, transition probabilities is nicely fitted by a Yule distribution, which is the observed distribution of the ranked short oligonucleotides frequency in DNA.

  14. Spin Rotation of Formalism for Spin Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Luccio,A.

    2008-02-01

    The problem of which coefficients are adequate to correctly represent the spin rotation in vector spin tracking for polarized proton and deuteron beams in synchrotrons is here re-examined in the light of recent discussions. The main aim of this note is to show where some previous erroneous results originated and how to code spin rotation in a tracking code. Some analysis of a recent experiment is presented that confirm the correctness of the assumptions.

  15. Transradial artery coronary angioplasty.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J; de Melker, E

    1995-01-01

    This study explored the feasibility and safety of percutaneous coronary balloon angioplasty (PTCA) with miniaturized PTCA equipment via the radial artery. Coronary angioplasty (PTCA) via the femoral or brachial arteries may be associated with rare vascular complications such as bleeding and damage to the artery and adjacent structures. It was postulated that PTCA via the radial artery with miniaturized angioplasty equipment is feasible and that no major puncture site-related complications occur because hemostasis is obtained easily and because no major structures are near the radial artery. With double blood supply to the hand, radial artery occlusion is well tolerated. In 100 patients with collateral blood supply to the right hand, PTCA was attempted with 6F guiding catheters and rapid-exchange balloon catheters for exertional angina (87 patients) or nonexertional angina (13 patients). Angioplasty was attempted in 122 lesions (type A n = 67 [55%], Type B n = 37 [30%], and type C n = 18 [15%]). Pre- and post-PTCA computerized quantitative coronary analysis was performed. Radial artery function and structure were assessed clinically and with Doppler and two-dimensional ultrasound on the day of discharge. Coronary catheterization via the radial artery was successful in 94 patients (94%). The 6 remaining patients had successful PTCA via the femoral artery (n = 5) or the brachial artery (n = 1). Procedural success (120 of 122 lesions) was achieved in 92 patients (98%) via the radial artery and in 98 patients of the total study population.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. From Label to Practice

    DEFF Research Database (Denmark)

    Byrkjeflot, Haldor; Strandgaard, Jesper; Svejenova, Silviya

    2013-01-01

    This article examines the process of creation of new Nordic cuisine (NNC) as a culinary innovation, focusing on the main stages, actors, and mechanisms that shaped the new label and its practices and facilitated its diffusion in the region and internationally. Fast-paced diffusion was possible...... because NNC was conceived as an identity movement, triggered by active involvement of entrepreneurial leaders from the culinary profession, high-profile political supporters, legitimating scientists, disseminating media, and interpreting audiences. It was facilitated by three mechanisms: First, the use...... actors and institutions to develop practices associated with the NNC label. Third, organized dissemination allowed the excitement and engagement with the new label to spread quickly....

  17. Acute occlusion of the left subclavian artery with artery dissection

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ Subclavian steal syndrome is cerebral or brain stem ischemia resulting from diversion of blood flow from the basilar artery to the subclavian artery, which is caused by occlusive disease of either the subclavian artery or the innominate artery before they branch off at the vertebral artery. In the patients with subclavian steal syndrome the subclavian artery is fed by retrograde flow from the vertebral artery via the carotids and the circle of Willis.

  18. Spin-Mechatronics

    Science.gov (United States)

    Matsuo, Mamoru; Saitoh, Eiji; Maekawa, Sadamichi

    2017-01-01

    We investigate the interconversion phenomena between spin and mechanical angular momentum in moving objects. In particular, the recent results on spin manipulation and spin-current generation by mechanical motion are examined. In accelerating systems, spin-dependent gauge fields emerge, which enable the conversion from mechanical angular momentum into spins. Such a spin-mechanical effect is predicted by quantum theory in a non-inertial frame. Experiments which confirm the effect, i.e., the resonance frequency shift in nuclear magnetic resonance, the stray field measurement of rotating metals, and electric voltage generation in liquid metals, are discussed.

  19. FDA Online Label Repository

    Data.gov (United States)

    U.S. Department of Health & Human Services — The drug labels and other drug-specific information on this Web site represent the most recent drug listing information companies have submitted to the Food and Drug...

  20. Behind the Label "Alcoholic."

    Science.gov (United States)

    Wright, Deborah M.

    1989-01-01

    Relates individual's personal story of her childhood influenced by her parent's alcoholism, her own alcoholism as a young adult, and her experiences with counseling. Asks others not to reject her because of the label "alcoholic." (ABL)

  1. Bilateral accessory thoracodorsal artery.

    Science.gov (United States)

    Natsis, Konstantinos; Totlis, Trifon; Tsikaras, Prokopios; Skandalakis, Panagiotis

    2006-09-01

    The subscapular artery arises from the third part of the axillary artery and gives off the circumflex scapular and the thoracodorsal arteries. Although anatomical variations of the axillary artery are very common, the existence of a unilateral accessory thoracodorsal artery has been described in the literature only once. There are no reports of bilateral accessory thoracodorsal artery, in the literature. In the present study, a bilateral accessory thoracodorsal artery, originating on either side of the third part of the axillary artery, is described in a 68-year-old female cadaver. All the other branches of the axillary artery had a typical origin, course, distribution and termination. This extremely rare anatomical variation apart from the anatomical importance also has clinical significance for surgeons in this area. Especially, during the dissection or mobilization of the latissimus dorsi that is partly used for coverage problems in many regions of the body and also in dynamic cardiomyoplasty, any iatrogenic injury of this accessory artery may result in ischemia and functional loss of the graft.

  2. Spin Transport by Collective Spin Excitations

    Science.gov (United States)

    Hammel, P. Chris

    We report studies of angular momentum transport in insulating materials. Our measurements reveal efficient spin pumping from high wavevector k spin waves in thin film Y3Fe5O12 (YIG): spin pumping is independent of wavevector up to k ~ 20 μm-1. Optical detection of YIG FMR by NV centers in diamond reveals a role for spin waves in this insulator-to-insulator spin transfer process. Spin transport is typically suppressed by insulating barriers, but we find that fluctuating antiferromagnetic correlations enable efficient spin transport at nm-scale thicknesses in insulating antiferromagnets, even in the absence of long-range order, and that the spin decay length increases with the strength of the antiferromagnetic correlations. This research is supported by the U.S. DOE through Grants DE-FG02-03ER46054 and DE-SC0001304, by the NSF MRSEC program through Grant No. 1420451 and by the Army Research Office through Grant W911NF0910147.

  3. Arbitrary Spin Galilean Oscillator

    CERN Document Server

    Hagen, C R

    2014-01-01

    The so-called Dirac oscillator was proposed as a modification of the free Dirac equation which reproduces many of the properties of the simple harmonic oscillator but accompanied by a strong spin-orbit coupling term. It has yet to be extended successfully to the arbitrary spin S case primarily because of the unwieldiness of general spin Lorentz invariant wave equations. It is shown here using the formalism of totally symmetric multispinors that the Dirac oscillator can, however, be made to accommodate spin by incorporating it into the framework of Galilean relativity. This is done explicitly for spin zero and spin one as special cases of the arbitrary spin result. For the general case it is shown that the coefficient of the spin-orbit term has a 1/S behavior by techniques which are virtually identical to those employed in the derivation of the g-factor carried out over four decades ago.

  4. Automatic classification of retinal vessels into arteries and veins

    Science.gov (United States)

    Niemeijer, Meindert; van Ginneken, Bram; Abràmoff, Michael D.

    2009-02-01

    Separating the retinal vascular tree into arteries and veins is important for quantifying vessel changes that preferentially affect either the veins or the arteries. For example the ratio of arterial to venous diameter, the retinal a/v ratio, is well established to be predictive of stroke and other cardiovascular events in adults, as well as the staging of retinopathy of prematurity in premature infants. This work presents a supervised, automatic method that can determine whether a vessel is an artery or a vein based on intensity and derivative information. After thinning of the vessel segmentation, vessel crossing and bifurcation points are removed leaving a set of vessel segments containing centerline pixels. A set of features is extracted from each centerline pixel and using these each is assigned a soft label indicating the likelihood that it is part of a vein. As all centerline pixels in a connected segment should be the same type we average the soft labels and assign this average label to each centerline pixel in the segment. We train and test the algorithm using the data (40 color fundus photographs) from the DRIVE database1 with an enhanced reference standard. In the enhanced reference standard a fellowship trained retinal specialist (MDA) labeled all vessels for which it was possible to visually determine whether it was a vein or an artery. After applying the proposed method to the 20 images of the DRIVE test set we obtained an area under the receiver operator characteristic (ROC) curve of 0.88 for correctly assigning centerline pixels to either the vein or artery classes.

  5. [Arterial hypertension among adolescents in Rio de Janeiro: prevalence and association with physical activity and obesity].

    Science.gov (United States)

    Corrêa-Neto, Victor Gonçalves; Sperandei, Sandro; Silva, Luis Aureliano Imbiriba; Maranhão-Neto, Geraldo de Albuquerque; Palma, Alexandre

    2014-06-01

    The scope of this study was to identify the prevalence of systemic arterial hypertension among adolescent students (aged 17-19 years) in the third and final year of high school in state schools in the municipality of Rio de Janeiro, and to investigate associations between systemic arterial hypertension and obesity and physical activity levels. Data on arterial pressure, body mass index and physical activity were gathered. The analysis included 854 individuals. Descriptive statistical analysis was applied to the sample, along with a Poisson regression model to determine the impact of the variables on the prevalence of systemic arterial hypertension. The prevalence of systemic arterial hypertension was 19.4%. Male sex, overweight and obesity presented significant positive associations with systemic arterial hypertension (p arterial hypertension (p > 0.05). The nature of these relationships should be interpreted in the light of reflection and not of passive labeling based on hegemonic concepts.

  6. Spinning Eggs and Ballerinas

    Science.gov (United States)

    Cross, Rod

    2013-01-01

    Measurements are presented on the rise of a spinning egg. It was found that the spin, the angular momentum and the kinetic energy all decrease as the egg rises, unlike the case of a ballerina who can increase her spin and kinetic energy by reducing her moment of inertia. The observed effects can be explained, in part, in terms of rolling friction…

  7. Celiac Artery Compression Syndrome

    Directory of Open Access Journals (Sweden)

    Mohammed Muqeetadnan

    2013-01-01

    Full Text Available Celiac artery compression syndrome is a rare disorder characterized by episodic abdominal pain and weight loss. It is the result of external compression of celiac artery by the median arcuate ligament. We present a case of celiac artery compression syndrome in a 57-year-old male with severe postprandial abdominal pain and 30-pound weight loss. The patient eventually responded well to surgical division of the median arcuate ligament by laparoscopy.

  8. Popliteal artery entrapment syndrome.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2010-01-01

    Popliteal artery entrapment syndrome is a rare abnormality of the anatomical relationship between the popliteal artery and adjacent muscles or fibrous bands in the popliteal fossa. The following is a case report of a 19 year old female, in whom popliteal artery entrapment syndrome was diagnosed, and successfully treated surgically. A review of literature is also presented and provides details on how PAES is classified, diagnosed both clinically and radiologically, and treated surgically.

  9. Arterial waveform analysis.

    Science.gov (United States)

    Esper, Stephen A; Pinsky, Michael R

    2014-12-01

    The bedside measurement of continuous arterial pressure values from waveform analysis has been routinely available via indwelling arterial catheterization for >50 years. Invasive blood pressure monitoring has been utilized in critically ill patients, in both the operating room and critical care units, to facilitate rapid diagnoses of cardiovascular insufficiency and monitor response to treatments aimed at correcting abnormalities before the consequences of either hypo- or hypertension are seen. Minimally invasive techniques to estimate cardiac output (CO) have gained increased appeal. This has led to the increased interest in arterial waveform analysis to provide this important information, as it is measured continuously in many operating rooms and intensive care units. Arterial waveform analysis also allows for the calculation of many so-called derived parameters intrinsically created by this pulse pressure profile. These include estimates of left ventricular stroke volume (SV), CO, vascular resistance, and during positive-pressure breathing, SV variation, and pulse pressure variation. This article focuses on the principles of arterial waveform analysis and their determinants, components of the arterial system, and arterial pulse contour. It will also address the advantage of measuring real-time CO by the arterial waveform and the benefits to measuring SV variation. Arterial waveform analysis has gained a large interest in the overall assessment and management of the critically ill and those at a risk of hemodynamic deterioration.

  10. European consumers and nutrition labelling

    DEFF Research Database (Denmark)

    Wills, Josephine M.; Grunert, Klaus G.; Celemín, Laura Fernández

    2009-01-01

    Nutrition labelling of food in Europe is not compulsory, unless a nutrition or health claim is made for the product. The European Commission is proposing mandatory nutrition labelling, even front of pack labelling with nutrition information. Yet, how widespread is nutrition labelling in the EU...

  11. Distance labeling schemes for trees

    DEFF Research Database (Denmark)

    Alstrup, Stephen; Gørtz, Inge Li; Bistrup Halvorsen, Esben;

    2016-01-01

    We consider distance labeling schemes for trees: given a tree with n nodes, label the nodes with binary strings such that, given the labels of any two nodes, one can determine, by looking only at the labels, the distance in the tree between the two nodes. A lower bound by Gavoille et al. [Gavoill...

  12. Hemorheological abnormalities in human arterial hypertension

    Science.gov (United States)

    Lo Presti, Rosalia; Hopps, Eugenia; Caimi, Gregorio

    2014-05-01

    Blood rheology is impaired in hypertensive patients. The alteration involves blood and plasma viscosity, and the erythrocyte behaviour is often abnormal. The hemorheological pattern appears to be related to some pathophysiological mechanisms of hypertension and to organ damage, in particular left ventricular hypertrophy and myocardial ischemia. Abnormalities have been observed in erythrocyte membrane fluidity, explored by fluorescence spectroscopy and electron spin resonance. This may be relevant for red cell flow in microvessels and oxygen delivery to tissues. Although blood viscosity is not a direct target of antihypertensive therapy, the rheological properties of blood play a role in the pathophysiology of arterial hypertension and its vascular complications.

  13. Anomalous origin of right coronary artery from pulmonary artery

    Directory of Open Access Journals (Sweden)

    Rajat Gupta

    2012-01-01

    Full Text Available Anomalous origin of coronary artery from the pulmonary artery is a rare anomaly that most frequently involves the left coronary artery and very rarely the right coronary artery. These lesions can be missed on echocardiography unless carefully looked for. We describe a case of isolated anomalous origin of right coronary artery from pulmonary artery diagnosed on echocardiography and confirmed by computed tomography (CT angiography.

  14. Inverse spin Hall effect by spin injection

    Science.gov (United States)

    Liu, S. Y.; Horing, Norman J. M.; Lei, X. L.

    2007-09-01

    Motivated by a recent experiment [S. O. Valenzuela and M. Tinkham, Nature (London) 442, 176 (2006)], the authors present a quantitative microscopic theory to investigate the inverse spin-Hall effect with spin injection into aluminum considering both intrinsic and extrinsic spin-orbit couplings using the orthogonalized-plane-wave method. Their theoretical results are in good agreement with the experimental data. It is also clear that the magnitude of the anomalous Hall resistivity is mainly due to contributions from extrinsic skew scattering.

  15. Spin supplementary conditions for spinning compact binaries

    CERN Document Server

    Mikóczi, Balázs

    2016-01-01

    We consider the different spin supplementary conditions (SSC) for a spinning compact binary with the leading-order spin-orbit (SO) interaction. The Lagrangian of the binary system can be constructed but it is acceleration-dependent in two cases of SSC. We rewrite the generalized Hamiltonian formalism proposed by Ostrogradsky and compute the conservative quantities and the dissipative part of relative motion during the gravitational radiation of each SSCs. We give the orbital elements and observed quantities of the SO dynamics, for instance the energy and the orbital angular momentum losses and waveforms and discuss their SSC dependence.

  16. Off label use of devices and drugs in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zvavanjanja, R.C., E-mail: Rodrick.Zvavanjanja@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool (United Kingdom); Odetoyinbo, T.O.; Rowlands, P.C.; Healey, A.; Abdelsalam, H.; Powell, S.; Evans, J.C.; Hughes, M.L.; Gould, D.A.; McWilliams, R.G. [Royal Liverpool University Hospital, Liverpool (United Kingdom)

    2012-03-15

    Aim: To establish how often off-label device and drug use occurs in interventional radiology (IR) in a UK tertiary referral hospital and consider the wider implications for the interventional radiologist. Materials and methods: Prospective data were collected during interventional procedures for 1 working week in a university hospital. Out-of-hours procedures and procedures outside the department were excluded. Operators were asked to record the drugs and devices used, the indication, and method of use. The instructions for use/summary of product characteristics were then studied for each device/drug used to assess if the use was on or off-label. Results: During the study period 52 cases were performed and data were available on 26 cases (50%). In 22 of the 26 cases (84%) there was evidence of off-label use of devices or drugs. Off-label use of drugs included treatment of venous malformations with Fibrovein{sup Copyright-Sign} (sodium tetradecyl sulphate), which is licensed for the treatment of varicose veins in the leg, and intra-arterial injection of heparin, which is licensed for intravenous and subcutaneous use. Off-label device use included placing vascular sheaths in the urinary tract, using angiographic catheters to guide wires in the urinary tract, using sheaths for thrombosuction, reshaping of the tip of most guidewires, and using angioplasty balloons to dislodge the arterial plug at fistula thrombectomy. Conclusion: Off-label device and drugs use is common in a UK tertiary hospital IR department and literature suggests this is common in the wider IR community. There are important clinical and legal implications for off-label use for patients and physicians.

  17. Kagome spin ice

    Science.gov (United States)

    Mellado, Paula

    Spin ice in magnetic pyrochlore oxides is a peculiar magnetic state. Like ordinary water ice, these materials are in apparent violation with the third law of thermodynamics, which dictates that the entropy of a system in thermal equilibrium vanishes as its temperature approaches absolute zero. In ice, a "zero-point" entropy is retained down to low temperatures thanks to a high number of low-energy positions of hydrogen ions associated with the Bernal-Fowler ice-rules. Spins in pyrochlore oxides Ho2Ti 2O7 and Dy2Ti2O7 exhibit a similar degeneracy of ground states and thus also have a sizable zero-point entropy. A recent discovery of excitations carrying magnetic charges in pyrochlore spin ice adds another interesting dimension to these magnets. This thesis is devoted to a theoretical study of a two-dimensional version of spin ice whose spins reside on kagome, a lattice of corner-sharing triangles. It covers two aspects of this frustrated classical spin system: the dynamics of artificial spin ice in a network of magnetic nanowires and the thermodynamics of crystalline spin ice. Magnetization dynamics in artificial spin ice is mediated by the emission, propagation and absorption of domain walls in magnetic nanowires. The dynamics shows signs of self-organized behavior such as avalanches. The theoretical model compares favorably to recent experiments. The thermodynamics of the microscopic version of spin ice on kagome is examined through analytical calculations and numerical simulations. The results show that, in addition to the high-temperature paramagnetic phase and the low-temperature phase with magnetic order, spin ice on kagome may have an intermediate phase with fluctuating spins and ordered magnetic charges. This work is concluded with a calculation of the entropy of kagome spin ice at zero temperature when one of the sublattices is pinned by an applied magnetic field and the system breaks up into independent spin chains, a case of dimensional reduction.

  18. Semantic Role Labeling

    CERN Document Server

    Palmer, Martha; Xue, Nianwen

    2011-01-01

    This book is aimed at providing an overview of several aspects of semantic role labeling. Chapter 1 begins with linguistic background on the definition of semantic roles and the controversies surrounding them. Chapter 2 describes how the theories have led to structured lexicons such as FrameNet, VerbNet and the PropBank Frame Files that in turn provide the basis for large scale semantic annotation of corpora. This data has facilitated the development of automatic semantic role labeling systems based on supervised machine learning techniques. Chapter 3 presents the general principles of applyin

  19. Labeling of Patient Specimens

    Science.gov (United States)

    2011-01-26

    noted during the event that the actu.al number of near miss incidmts reported monthly was low due to laboratory personnel performing rounds each...specimens never leaves label and if moved it is labeled), All orders in system and all near misses and errors reported to patient safety Purchase/Install...Meeting 14 Aug 09, 1400 in lab break room thru out Develop TICK sheet to track near misses .JDI Ms. Clark Clinics will provide toPS 1st working day of

  20. Indium-111-labeled platelet scintigraphy in carotid atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Minar, E.; Ehringer, H.; Dudczak, R.; Schoefl, R.J.; Jung, M.; Koppensteiner, R.; Ahmadi, R.; Kretschmer, G.

    1989-01-01

    We evaluated platelet accumulation in carotid arteries by means of a dual-radiotracer method, using indium-111-labeled platelets and technetium-99m-labeled human serum albumin, in 123 patients (92 men, 31 women; median age 60 years). Sixty patients had symptoms of transient ischemic carotid artery disease, and 63 patients with peripheral arterial occlusive disease served as controls. Antiplatelet treatment with acetylsalicylic acid was taken by 53 of the 123 patients. In 36 of the 60 symptomatic patients, platelet scintigraphy was repeated 3-4 days after carotid endarterectomy. Comparison of different scintigraphic parameters (platelet accumulation index and percent of the injected dose of labeled platelets at the carotid bifurcation) showed no significant differences between symptomatic and asymptomatic patients, and the severity of stenosis and the presence of plaque ulceration also had no influence on the parameters. There was no difference between patients with a short (less than 4 weeks) or long (greater than 4 weeks) interval from the last transient ischemic attack to scintigraphy and no difference between patients with or without antiplatelet treatment. Classifying the patients according to plaque morphology judged by high-resolution real-time ultrasonography also demonstrated no differences. No significant correlation was found between any scintigraphic parameter and other platelet function parameters such as platelet survival time, platelet turnover rate, and concentration of platelet-specific proteins. Quantification of platelet deposition after carotid endarterectomy in 36 patients demonstrated a significant increase of the median platelet accumulation index and the percent injected dose index.

  1. Spinning particles and higher spin field equations

    CERN Document Server

    Bastianelli, Fiorenzo; Corradini, Olindo; Latini, Emanuele

    2015-01-01

    Relativistic particles with higher spin can be described in first quantization using actions with local supersymmetry on the worldline. First, we present a brief review of these actions and their use in first quantization. In a Dirac quantization scheme the field equations emerge as Dirac constraints on the Hilbert space, and we outline how they lead to the description of higher spin fields in terms of the more standard Fronsdal-Labastida equations. Then, we describe how these actions can be extended so that the propagating particle is allowed to take different values of the spin, i.e. carry a reducible representation of the Poincar\\'e group. This way one may identify a four dimensional model that carries the same degrees of freedom of the minimal Vasiliev's interacting higher spin field theory. Extensions to massive particles and to propagation on (A)dS spaces are also briefly commented upon.

  2. Slow spin relaxation in dipolar spin ice.

    Science.gov (United States)

    Orendac, Martin; Sedlakova, Lucia; Orendacova, Alzbeta; Vrabel, Peter; Feher, Alexander; Pajerowski, Daniel M.; Cohen, Justin D.; Meisel, Mark W.; Shirai, Masae; Bramwell, Steven T.

    2009-03-01

    Spin relaxation in dipolar spin ice Dy2Ti2O7 and Ho2Ti2O7 was investigated using the magnetocaloric effect and susceptibility. The magnetocaloric behavior of Dy2Ti2O7 at temperatures where the orientation of spins is governed by ``ice rules`` (T Tice) revealed thermally activated relaxation; however, the resulting temperature dependence of the relaxation time is more complicated than anticipated by a mere extrapolation of the corresponding high temperature data [1]. A susceptibility study of Ho2Ti2O7 was performed at T > Tice and in high magnetic fields, and the results suggest a slow relaxation of spins analogous to the behavior reported in a highly polarized cooperative paramagnet [2]. [1] J. Snyder et al., Phys. Rev. Lett. 91 (2003) 107201. [2] B. G. Ueland et al., Phys. Rev. Lett. 96 (2006) 027216.

  3. Arterial hypoxaemia in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Hillingsø, Jens; Christensen, E

    1998-01-01

    BACKGROUND: Although low arterial oxygen tension (Po2) has been claimed to occur in one to two thirds of patients with cirrhosis, hypoxaemia appears to be rare in clinical practice. AIMS: To assess the frequency of arterial hypoxaemia in cirrhosis in relation to clinical and haemodynamic......%, 96%, 96%, and 93% (NS). So2 was below the lower limit of 92% in 0%, 9%, 7%, and 24% (p arterial carbon dioxide tension, a low systemic vascular...... resistance, and a low indocyanine green clearance (p arterial hypoxaemia in cirrhosis is about 22% in patients without encephalopathy, but it varies from 10-40% depending on the degree of hepatic dysfunction. Arterial hypoxaemia in patients with cirrhosis of differing...

  4. Artery by Neuropeptides

    Directory of Open Access Journals (Sweden)

    Esmeralda Sofia Costa Delgado

    2012-01-01

    Methods. Isolated rabbit eyes (n=12 were perfused in situ with tyrode through the external ophthalmic artery. Effects of intra-arterial injections of NPY 200 μg/ml (Group A; n=6 and VIP 200 μg/ml (Group B; n=6 on the recorded pressure were obtained. For statistical analysis, Student's paired t-test and Fast Fourier Transform were used. Results. Spontaneous oscillations were observed before any drug administration in the 12 rabbit models. NPY produced an increase in total vascular resistance and a higher frequency and amplitude of oscillations, while VIP evoked the opposite effects. Conclusions. This study provides evidence of vasomotion in basal conditions in rabbit external ophthalmic artery. Concerning drug effects, NPY increased arterial resistance and enhanced vasomotion while VIP produced opposite effects which demonstrates their profound influence in arterial vasomotion.

  5. [Transposition of Great Artery].

    Science.gov (United States)

    Konuma, Takeshi; Shimpo, Hideto

    2015-07-01

    Transposition of the great artery is one of common congenital cardiac disease resulting cyanosis. Death occurs easily in untreated patients with transposition and intact ventricular septal defect (VSD) in infancy at a few days of age when posterior descending coronary artery (PDA) closed. Since there are 2 parallel circulations, flow from pulmonary to systemic circulation is necessary for systemic oxygenation, and Balloon atrial septostomy or prostaglandin infusion should be performed especially if patient do not have VSD. Although the advent of fetal echocardiography, it is difficult to diagnose the transposition of the great arteries (TGA) as abnormality of great vessels is relatively undistinguishable. The diagnosis of transposition is in itself an indication for surgery, and arterial switch procedure is performed in the case the left ventricle pressure remains more than 2/3 of systemic pressure. Preoperative diagnosis is important as associated anomalies and coronary artery branching patterns are important to decide the operative indication and timing of surgery.

  6. Developmental origin of age-related coronary artery disease

    Science.gov (United States)

    Wei, Ke; Díaz-Trelles, Ramon; Liu, Qiaozhen; Diez-Cuñado, Marta; Scimia, Maria-Cecilia; Cai, Wenqing; Sawada, Junko; Komatsu, Masanobu; Boyle, Joseph J.; Zhou, Bin; Ruiz-Lozano, Pilar; Mercola, Mark

    2015-01-01

    Aim Age and injury cause structural and functional changes in coronary artery smooth muscle cells (caSMCs) that influence the pathogenesis of coronary artery disease. Although paracrine signalling is widely believed to drive phenotypic changes in caSMCs, here we show that developmental origin within the fetal epicardium can have a profound effect as well. Methods and results Fluorescent dye and transgene pulse-labelling techniques in mice revealed that the majority of caSMCs are derived from Wt1+, Gata5-Cre+ cells that migrate before E12.5, whereas a minority of cells are derived from a later-emigrating, Wt1+, Gata5-Cre− population. We functionally evaluated the influence of early emigrating cells on coronary artery development and disease by Gata5-Cre excision of Rbpj, which prevents their contribution to coronary artery smooth muscle cells. Ablation of the Gata5-Cre+ population resulted in coronary arteries consisting solely of Gata5-Cre− caSMCs. These coronary arteries appeared normal into early adulthood; however, by 5–8 months of age, they became progressively fibrotic, lost the adventitial outer elastin layer, were dysfunctional and leaky, and animals showed early mortality. Conclusion Taken together, these data reveal heterogeneity in the fetal epicardium that is linked to coronary artery integrity, and that distortion of the coronaries epicardial origin predisposes to adult onset disease. PMID:26054850

  7. Spin accumulation in the extrinsic spin Hall effect

    Science.gov (United States)

    Tse, Wang-Kong; Fabian, J.; Žutić, I.; Das Sarma, S.

    2005-12-01

    The drift-diffusion formalism for spin-polarized carrier transport in semiconductors is generalized to include spin-orbit coupling. The theory is applied to treat the extrinsic spin Hall effect using realistic boundary conditions. It is shown that carrier and spin-diffusion lengths are modified by the presence of spin-orbit coupling and that spin accumulation due to the extrinsic spin Hall effect is strongly and qualitatively influenced by boundary conditions. Analytical formulas for the spin-dependent carrier recombination rates and inhomogeneous spin densities and currents are presented.

  8. Figuring Out Food Labels

    Science.gov (United States)

    ... should get 30%-40% of calories from fat. Saturated Fat and Trans Fat The amount of saturated fat appears beneath total fat. The FDA also requires ... to list trans fats separately on the label. Saturated fats and trans fats are often called "bad fats" ...

  9. Labelled Execution Systems

    Science.gov (United States)

    2012-05-07

    This is most starkly evident in the classical example used to demonstrate that, in the case of infinitely branching systems, a transfinite number of... transfinite number of iterations to converge, what can be shown to fail by appropriately embedding the labelled transition systems of [46, prop. 10.5

  10. Multi-label

    Directory of Open Access Journals (Sweden)

    Neda Abdelhamid

    2015-01-01

    Full Text Available Generating multi-label rules in associative classification (AC from single label data sets is considered a challenging task making the number of existing algorithms for this task rare. Current AC algorithms produce only the largest frequency class connected with a rule in the training data set and discard all other classes even though these classes have data representation with the rule’s body. In this paper, we deal with the above problem by proposing an AC algorithm called Enhanced Multi-label Classifiers based Associative Classification (eMCAC. This algorithm discovers rules associated with a set of classes from single label data that other current AC algorithms are unable to induce. Furthermore, eMCAC minimises the number of extracted rules using a classifier building method. The proposed algorithm has been tested on a real world application data set related to website phishing and the results reveal that eMCAC’s accuracy is highly competitive if contrasted with other known AC and classic classification algorithms in data mining. Lastly, the experimental results show that our algorithm is able to derive new rules from the phishing data sets that end-users can exploit in decision making.

  11. Waisda?: video labeling game

    NARCIS (Netherlands)

    Hildebrand, M.; Brinkerink, M.; Gligorov, R.; Steenbergen, M. van; Huijkman, J.; Oomen, J.

    2013-01-01

    The Waisda? video labeling game is a crowsourcing tool to collect user-generated metadata for video clips. It follows the paradigm of games-with-a-purpose, where two or more users play against each other by entering tags that describe the content of the video. Players score points by entering the sa

  12. Long-Lived Heteronuclear Spin-Singlet States in Liquids at a Zero Magnetic field

    Science.gov (United States)

    Emondts, M.; Ledbetter, M. P.; Pustelny, S.; Theis, T.; Patton, B.; Blanchard, J. W.; Butler, M. C.; Budker, D.; Pines, A.

    2014-02-01

    We report an observation of long-lived spin-singlet states in a C-H113 spin pair in a zero magnetic field. In C13-labeled formic acid, we observe spin-singlet lifetimes as long as 37 s, about a factor of 3 longer than the T1 lifetime of dipole polarization in the triplet state. In contrast to common high-field experiments, the observed coherence is a singlet-triplet coherence with a lifetime T2 longer than the T1 lifetime of dipole polarization in the triplet manifold. Moreover, we demonstrate that heteronuclear singlet states formed between a H1 and a C13 nucleus can exhibit longer lifetimes than the respective triplet states even in the presence of additional spins that couple to the spin pair of interest. Although long-lived homonuclear spin-singlet states have been extensively studied, this is the first experimental observation of analogous singlet states in heteronuclear spin pairs.

  13. Higher spin gauge theories

    CERN Document Server

    Henneaux, Marc; Vasiliev, Mikhail A

    2017-01-01

    Symmetries play a fundamental role in physics. Non-Abelian gauge symmetries are the symmetries behind theories for massless spin-1 particles, while the reparametrization symmetry is behind Einstein's gravity theory for massless spin-2 particles. In supersymmetric theories these particles can be connected also to massless fermionic particles. Does Nature stop at spin-2 or can there also be massless higher spin theories. In the past strong indications have been given that such theories do not exist. However, in recent times ways to evade those constraints have been found and higher spin gauge theories have been constructed. With the advent of the AdS/CFT duality correspondence even stronger indications have been given that higher spin gauge theories play an important role in fundamental physics. All these issues were discussed at an international workshop in Singapore in November 2015 where the leading scientists in the field participated. This volume presents an up-to-date, detailed overview of the theories i...

  14. Taking a molecular motor for a spin: helicase mechanism studied by spin labeling and PELDOR

    Science.gov (United States)

    Constantinescu-Aruxandei, Diana; Petrovic-Stojanovska, Biljana; Schiemann, Olav; Naismith, James H.; White, Malcolm F.

    2016-01-01

    The complex molecular motions central to the functions of helicases have long attracted attention. Protein crystallography has provided transformative insights into these dynamic conformational changes, however important questions about the true nature of helicase configurations during the catalytic cycle remain. Using pulsed EPR (PELDOR or DEER) to measure interdomain distances in solution, we have examined two representative helicases: PcrA from superfamily 1 and XPD from superfamily 2. The data show that PcrA is a dynamic structure with domain movements that correlate with particular functional states, confirming and extending the information gleaned from crystal structures and other techniques. XPD in contrast is shown to be a rigid protein with almost no conformational changes resulting from nucleotide or DNA binding, which is well described by static crystal structures. Our results highlight the complimentary nature of PELDOR to crystallography and the power of its precision in understanding the conformational changes relevant to helicase function. PMID:26657627

  15. Quantum Spin Gyroscope

    Science.gov (United States)

    2015-07-15

    Progress Report (ONR Award No. N00014-14-1-0804) Quantum Spin Gyroscope August 2014-July 2015 Report Type: Annual Report Primary Contact E-mail... Quantum Spin Gyroscope Grant/Contract Number: N00014-14-1-0804 Principal Investigator Name: Paola Cappellaro Program Manager: Richard Tommy Willis...required large volumes. Our project aims at overcoming these drawbacks by developing a novel solid-state quantum spin gyro- scope associated with the

  16. Spin coating apparatus

    Science.gov (United States)

    Torczynski, John R.

    2000-01-01

    A spin coating apparatus requires less cleanroom air flow than prior spin coating apparatus to minimize cleanroom contamination. A shaped exhaust duct from the spin coater maintains process quality while requiring reduced cleanroom air flow. The exhaust duct can decrease in cross section as it extends from the wafer, minimizing eddy formation. The exhaust duct can conform to entrainment streamlines to minimize eddy formation and reduce interprocess contamination at minimal cleanroom air flow rates.

  17. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  18. Coronary Artery Bypass

    Directory of Open Access Journals (Sweden)

    Kadri Ceberut

    2011-01-01

    Full Text Available Ancient schwannoma is a rare variant of neural tumors though rarely seen in the thorax. The combination with coronary artery diseases is also rare. Here we describe a 66 year-old male who had undergone one-stage combined surgery for thoracic ancient schwannomas removal and coronary artery disease. The masses were, respectively, 13 cm in the middle mediastinum and 5 cm in diameter originating from the intercostal nerve. The tumors were successfully removed using sternotomy, and then a coronary artery bypass grafting was performed. Here we discuss this rare tumor in relation to the relevant literature.

  19. Picosecond Spin Seebeck Effect

    Science.gov (United States)

    Kimling, Johannes; Choi, Gyung-Min; Brangham, Jack T.; Matalla-Wagner, Tristan; Huebner, Torsten; Kuschel, Timo; Yang, Fengyuan; Cahill, David G.

    2017-02-01

    We report time-resolved magneto-optic Kerr effect measurements of the longitudinal spin Seebeck effect in normal metal /Y3Fe5 O12 bilayers driven by an interfacial temperature difference between electrons and magnons. The measured time evolution of spin accumulation induced by laser excitation indicates transfer of angular momentum across normal metal /Y3Fe5 O12 interfaces on a picosecond time scale, too short for contributions from a bulk temperature gradient in an yttrium iron garnet. The product of spin-mixing conductance and the interfacial spin Seebeck coefficient determined is of the order of 108 A m-2 K-1 .

  20. Picosecond spin Seebeck effect

    OpenAIRE

    Kimling, Johannes; Choi, Gyung-Min; Brangham, Jack T.; Matalla-Wagner, Tristan; Huebner, Torsten; Kuschel, Timo; Yang, Fengyuan; Cahill, David G.

    2016-01-01

    We report time-resolved magneto-optic Kerr effect measurements of the longitudinal spin Seebeck effect driven by an interfacial temperature difference between itinerant electrons and magnons. The measured time-evolution of spin accumulation induced by laser-excitation indicates transfer of angular momentum across Au/Y$_3$Fe$_5$O$_{12}$ and Cu/Y$_3$Fe$_5$O$_{12}$ interfaces on a picosecond time-scale. The product of spin-mixing conductance and interfacial spin Seebeck coefficient determined is...

  1. Decode the Sodium Label Lingo

    Science.gov (United States)

    ... For Preschooler For Gradeschooler For Teen Decode the Sodium Label Lingo Published January 24, 2013 Print Email Reading food labels can help you slash sodium. Here's how to decipher them. "Sodium free" or " ...

  2. A quantum spin-probe molecular microscope

    Science.gov (United States)

    Perunicic, V. S.; Hill, C. D.; Hall, L. T.; Hollenberg, L. C. L.

    2016-10-01

    Imaging the atomic structure of a single biomolecule is an important challenge in the physical biosciences. Whilst existing techniques all rely on averaging over large ensembles of molecules, the single-molecule realm remains unsolved. Here we present a protocol for 3D magnetic resonance imaging of a single molecule using a quantum spin probe acting simultaneously as the magnetic resonance sensor and source of magnetic field gradient. Signals corresponding to specific regions of the molecule's nuclear spin density are encoded on the quantum state of the probe, which is used to produce a 3D image of the molecular structure. Quantum simulations of the protocol applied to the rapamycin molecule (C51H79NO13) show that the hydrogen and carbon substructure can be imaged at the angstrom level using current spin-probe technology. With prospects for scaling to large molecules and/or fast dynamic conformation mapping using spin labels, this method provides a realistic pathway for single-molecule microscopy.

  3. A quantum spin-probe molecular microscope

    Science.gov (United States)

    Perunicic, V. S.; Hill, C. D.; Hall, L. T.; Hollenberg, L.C.L.

    2016-01-01

    Imaging the atomic structure of a single biomolecule is an important challenge in the physical biosciences. Whilst existing techniques all rely on averaging over large ensembles of molecules, the single-molecule realm remains unsolved. Here we present a protocol for 3D magnetic resonance imaging of a single molecule using a quantum spin probe acting simultaneously as the magnetic resonance sensor and source of magnetic field gradient. Signals corresponding to specific regions of the molecule's nuclear spin density are encoded on the quantum state of the probe, which is used to produce a 3D image of the molecular structure. Quantum simulations of the protocol applied to the rapamycin molecule (C51H79NO13) show that the hydrogen and carbon substructure can be imaged at the angstrom level using current spin-probe technology. With prospects for scaling to large molecules and/or fast dynamic conformation mapping using spin labels, this method provides a realistic pathway for single-molecule microscopy. PMID:27725630

  4. Two-Dimensional Electron-Spin Resonance

    Science.gov (United States)

    Freed, Jack H.

    2000-03-01

    The extension of the concepts of 2D-NMR to ESR posed significant technological challenges, especially for liquids. ESR relaxation times are very short, as low as 10-15 ns. for T_2's. Spectral bandwidths are 100-250 MHz for nitroxide spin labels. Adequate coverage is obtained with 3-5 ns. π/2 (9-17 GHz) microwave pulses into a small low Q resonator. Dead-times are currently 25-30 ns. Additional requirements are rapid phase shifting for phase cycling, nsec. data acquisition, and fast repetition rates (10-100 kHz). 2D-ELDOR (electron-electron double resonance), which is a 3-pulse 2D-exchange experiment, takes about 30 minutes with just 0.5 nanomole spin-probe in solution (SNR 200). 2D-ELDOR is very useful in studies of molecular dynamics and local structure in complex fluids. For such media, the slow rotational dynamics requires a theory based upon the stochastic Liouville equation which enables quantitative interpretation of 2D-ELDOR experiments. In studies of spin-probes in a liquid crystal new insights could be obtained on the dynamic structure in different phases. One obtains, in addition to ordering and reorientation rates of the probes, details of the local dynamic cage: its orienting potential and (slow) relaxation rate. 2D-ELDOR overcomes the loss of resolution resulting from microscopically ordered but macroscopically disordered complex fluids. This is illustrated by studies of the dynamic structure of lipid membrane vesicles, and the effects of adding a peptide. The short dead times enable the observation of both the bulk lipids and the more immobilized lipids that coat (or are trapped) by the (aggregates of) peptides. Also, new developments of multi-quantum (2D) FT-ESR from nitroxide spin labels interacting by dipolar interactions show considerable promise in measuring distances of ca. 15-70A in macromolecules.

  5. Renal arteries (image)

    Science.gov (United States)

    A renal angiogram is a test used to examine the blood vessels of the kidneys. The test is performed ... main vessel of the pelvis, up to the renal artery that leads into the kidney. Contrast medium ...

  6. Coronary Artery Bypass Surgery

    Science.gov (United States)

    ... t help, you may need coronary artery bypass surgery. The surgery creates a new path for blood to flow ... more than one bypass. The results of the surgery usually are excellent. Many people remain symptom-free ...

  7. Carotid Artery Disease

    Science.gov (United States)

    ... make them more vulnerable to damage. Tobacco use. Nicotine can irritate the inner lining of your arteries. ... your physical and mental capabilities such as strength, memory and speech. After that, your doctor may recommend: ...

  8. Pulmonary Arterial Hypertension

    Science.gov (United States)

    Pulmonary Arterial Hypertension What Is Pulmonary Hypertension? To understand pulmonary hypertension (PH) it helps to understand how blood ows throughout your body. While the heart is one organ, it ...

  9. Labelling GM-free Products

    DEFF Research Database (Denmark)

    Punt, Maarten; Venus, Thomas; Wesseler, Justus

    2016-01-01

    Food suppliers in the EU must comply with labelling regulations for genetically modified organisms (GMOs). However, excluded from mandatory labelling are food products derived from animals fed with GM feed (mainly GM soybean in the EU). Because of this labelling exemption, consumers are unable to...

  10. Scaffolding Visitors' Learning through Labels

    Science.gov (United States)

    Wang, Joyce; Yoon, Susan

    2013-01-01

    In museum literature, labels have been found to increase visitor learning and contribute to greater cognitive gains. In this study, we seek to understand how various labels support the visitors' learning experience, and specifically in regards to conceptual and cognitive learning. We investigated the increasing use of three types of labels (visual…

  11. Food Labels Tell the Story!

    Science.gov (United States)

    ... My World From the Label to the Table! Food Labels Tell the Story! What is in food? Food provides your body with all of the ... your food choices. Nutrition Facts—the Labels on Food Products Beginning in 1994, the US government began ...

  12. Heritability of cilioretinal arteries

    DEFF Research Database (Denmark)

    Taarnhøj, Nina Charlotte; Munch, Inger C; Kyvik, Kirsten O;

    2005-01-01

    PURPOSE: To determine whether the presence of one or more cilioretinal arteries, a distinct element of the pattern of fundus vessels, is genetically programmed, influenced by environmental factors, or the result of random mechanisms of vascular development. METHODS: The fundi of 112 pairs...... environmental factors. CONCLUSIONS: The presence or absence of one or more cilioretinal arteries in healthy persons is markedly influenced by genetic factors....

  13. Physics lab in spin

    CERN Multimedia

    Hawkes, N

    1999-01-01

    RAL is fostering commerical exploitation of its research and facilities in two main ways : spin-out companies exploit work done at the lab, spin-in companies work on site taking advantage of the facilities and the expertise available (1/2 page).

  14. Antiferromagnetic spin Seebeck effect.

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Stephen M.; Zhang, Wei; KC, Amit; Borisov, Pavel; Pearson, John E.; Jiang, J. Samuel; Lederman, David; Hoffmann, Axel; Bhattacharya, Anand

    2016-03-03

    We report on the observation of the spin Seebeck effect in antiferromagnetic MnF2. A device scale on-chip heater is deposited on a bilayer of MnF2 (110) (30nm)/Pt (4 nm) grown by molecular beam epitaxy on a MgF2(110) substrate. Using Pt as a spin detector layer, it is possible to measure the thermally generated spin current from MnF2 through the inverse spin Hall effect. The low temperature (2–80 K) and high magnetic field (up to 140 kOe) regime is explored. A clear spin-flop transition corresponding to the sudden rotation of antiferromagnetic spins out of the easy axis is observed in the spin Seebeck signal when large magnetic fields (>9T) are applied parallel to the easy axis of the MnF2 thin film. When the magnetic field is applied perpendicular to the easy axis, the spin-flop transition is absent, as expected.

  15. Antiferromagnetic Spin Seebeck Effect

    Science.gov (United States)

    Wu, Stephen M.; Zhang, Wei; KC, Amit; Borisov, Pavel; Pearson, John E.; Jiang, J. Samuel; Lederman, David; Hoffmann, Axel; Bhattacharya, Anand

    2016-03-01

    We report on the observation of the spin Seebeck effect in antiferromagnetic MnF2 . A device scale on-chip heater is deposited on a bilayer of MnF2 (110) (30 nm )/Pt (4 nm) grown by molecular beam epitaxy on a MgF2 (110) substrate. Using Pt as a spin detector layer, it is possible to measure the thermally generated spin current from MnF2 through the inverse spin Hall effect. The low temperature (2-80 K) and high magnetic field (up to 140 kOe) regime is explored. A clear spin-flop transition corresponding to the sudden rotation of antiferromagnetic spins out of the easy axis is observed in the spin Seebeck signal when large magnetic fields (>9 T ) are applied parallel to the easy axis of the MnF2 thin film. When the magnetic field is applied perpendicular to the easy axis, the spin-flop transition is absent, as expected.

  16. Single spin magnetic resonance

    Science.gov (United States)

    Wrachtrup, Jörg; Finkler, Amit

    2016-08-01

    Different approaches have improved the sensitivity of either electron or nuclear magnetic resonance to the single spin level. For optical detection it has essentially become routine to observe a single electron spin or nuclear spin. Typically, the systems in use are carefully designed to allow for single spin detection and manipulation, and of those systems, diamond spin defects rank very high, being so robust that they can be addressed, read out and coherently controlled even under ambient conditions and in a versatile set of nanostructures. This renders them as a new type of sensor, which has been shown to detect single electron and nuclear spins among other quantities like force, pressure and temperature. Adapting pulse sequences from classic NMR and EPR, and combined with high resolution optical microscopy, proximity to the target sample and nanoscale size, the diamond sensors have the potential to constitute a new class of magnetic resonance detectors with single spin sensitivity. As diamond sensors can be operated under ambient conditions, they offer potential application across a multitude of disciplines. Here we review the different existing techniques for magnetic resonance, with a focus on diamond defect spin sensors, showing their potential as versatile sensors for ultra-sensitive magnetic resonance with nanoscale spatial resolution.

  17. Spin Waves in Terbium

    DEFF Research Database (Denmark)

    Jensen, J.; Houmann, Jens Christian Gylden; Bjerrum Møller, Hans

    1975-01-01

    with increasing temperatures implies that the two-ion coupling is effectively isotropic above ∼ 150 K. We present arguments for concluding that, among the mechanisms which may introduce anisotropic two-ion couplings in the rare-earth metals, the modification of the indirect exchange interaction by the spin......The energies of spin waves propagating in the c direction of Tb have been studied by inelastic neutron scattering, as a function of a magnetic field applied along the easy and hard directions in the basal plane, and as a function of temperature. From a general spin Hamiltonian, consistent...... with the symmetry, we deduce the dispersion relation for the spin waves in a basal-plane ferromagnet. This phenomenological spin-wave theory accounts for the observed behavior of the magnon energies in Tb. The two q⃗-dependent Bogoliubov components of the magnon energies are derived from the experimental results...

  18. Antiferromagnetic spin Seebeck Effect

    OpenAIRE

    Wu, SM; W. Zhang; Kc, A; Borisov, P.; Pearson, JE; Jiang, JS; Lederman, D.; Hoffmann, A.; Bhattacharya, A

    2015-01-01

    We report on the observation of the spin Seebeck effect in antiferromagnetic MnF_{2}. A device scale on-chip heater is deposited on a bilayer of MnF_{2} (110) (30  nm)/Pt (4 nm) grown by molecular beam epitaxy on a MgF_{2} (110) substrate. Using Pt as a spin detector layer, it is possible to measure the thermally generated spin current from MnF_{2} through the inverse spin Hall effect. The low temperature (2-80 K) and high magnetic field (up to 140 kOe) regime is explored. A clear spin-flop t...

  19. Fractionalized spin-wave continuum in kagome spin liquids

    Science.gov (United States)

    Mei, Jia-Wei; Wen, Xiao-Gang

    Motivated by spin-wave continuum (SWC) observed in recent neutron scattering experiments in Herbertsmithite, we use Gutzwiller-projected wave functions to study dynamic spin structure factor S (q , ω) of spin liquid states on the kagome lattice. Spin-1 excited states in spin liquids are represented by Gutzwiller-projected two-spinon excited wave functions. We investigate three different spin liquid candidates, spinon Fermi-surface spin liquid (FSL), Dirac spin liquid (DSL) and random-flux spin liquid (RSL). FSL and RSL have low energy peaks in S (q , ω) at K points in the extended magnetic Brillouin zone, in contrast to experiments where low energy peaks are found at M points. There is no obviuos contradiction between DSL and neutron scattering measurements. Besides a fractionalized spin (i.e. spin-1/2), spinons in DSL carry a fractionalized crystal momentum which is potentially detectable in SWC in the neutron scattering measurements.

  20. Spin transport at interfaces with spin-orbit coupling: Formalism

    Science.gov (United States)

    Amin, V. P.; Stiles, M. D.

    2016-09-01

    We generalize magnetoelectronic circuit theory to account for spin transfer to and from the atomic lattice via interfacial spin-orbit coupling. This enables a proper treatment of spin transport at interfaces between a ferromagnet and a heavy-metal nonmagnet. This generalized approach describes spin transport in terms of drops in spin and charge accumulations across the interface (as in the standard approach), but additionally includes the responses from in-plane electric fields and offsets in spin accumulations. A key finding is that in-plane electric fields give rise to spin accumulations and spin currents that can be polarized in any direction, generalizing the Rashba-Edelstein and spin Hall effects. The spin accumulations exert torques on the magnetization at the interface when they are misaligned from the magnetization. The additional out-of-plane spin currents exert torques via the spin-transfer mechanism on the ferromagnetic layer. To account for these phenomena we also describe spin torques within the generalized circuit theory. The additional effects included in this generalized circuit theory suggest modifications in the interpretations of experiments involving spin-orbit torques, spin pumping, spin memory loss, the Rashba-Edelstein effect, and the spin Hall magnetoresistance.

  1. Spin Hall and spin Nernst effects in graphene with intrinsic and Rashba spin-orbit interactions

    Institute of Scientific and Technical Information of China (English)

    Zhu Guo-Bao

    2012-01-01

    The spin Hall and spin Nernst effects in graphene are studied based on Green's function formalism.We calculate intrinsic contributions to spin Hall and spin Nernst conductivities in the Kane-Mele model with various structures.When both intrinsic and Rashba spin-orbit interactions are present,their interplay leads to some characteristics of the dependence of spin Hall and spin Nernst conductivities on the Fermi level.When the Rashba spin-orbit interaction is smaller than intrinsic spin-orbit coupling,a weak kink in the conductance appears.The kink disappears and a divergence appears when the Rashba spin-orbit interaction enhances.When the Rashba spin-orbit interaction approaches and is stronger than intrinsic spin-orbit coupling,the divergence becomes more obvious.

  2. Coronary anomaly: the single coronary artery

    Institute of Scientific and Technical Information of China (English)

    QIN Xu-guang; XIONG Wei-guo; LU Chun-peng; GONG Cheng-jie; SHANG Li-hua

    2010-01-01

    @@ Single coronary artery (SCA), defined as an artery that arises from the arterial trunk and nourishes the entire myocardium, is rare. We report two cases of SCA, one is the right coronary artery (RCA) originating from the middle of left descending artery (LAD), and the other is the left main coronary artery (LMCA) arising from the proximal right coronary artery.

  3. Map labeling and its generalizations

    Energy Technology Data Exchange (ETDEWEB)

    Doddi, S. [New Mexico Univ., Albuquerque, NM (United States). Dept. of Computer Science]|[Los Alamos National Lab., NM (United States); Marathe, M.V. [Los Alamos National Lab., NM (United States); Mirzaian, A. [York Univ., Toronto, ON (Canada). Dept. of Computer Science; Moret, B.M.E. [New Mexico Univ., Albuquerque, NM (United States). Dept. of Computer Science; Zhu, B. [City Univ. of Hong Kong (Hong Kong). Dept. of Computer Science]|[Los Alamos National Lab., NM (United States)

    1997-01-01

    Map labeling is of fundamental importance in cartography and geographical information systems and is one of the areas targeted for research by the ACM Computational Geometry Impact Task Force. Previous work on map labeling has focused on the problem of placing maximal uniform, axis-aligned, disjoint rectangles on the plane so that each point feature to be labeled lies at the corner of one rectangle. Here, we consider a number of variants of the map labeling problem. We obtain three general types of results. First, we devise constant-factor polynomial-time-approximation algorithms for labeling point features by rectangular labels, where the feature may lie anywhere on the boundary of its label region and where labeling rectangles may be placed in any orientation. These results generalize to the case of elliptical labels. Secondly, we consider the problem of labeling a map consisting of disjoint rectilinear fine segments. We obtain constant-factor polynomial-time approximation algorithms for the general problem and an optimal algorithm for the special case where all segments are horizontal. Finally, we formulate a bicriteria version of the map-labeling problem and provide bicriteria polynomial- time approximation schemes for a number of such problems.

  4. Linerless label device and method

    KAUST Repository

    Binladen, Abdulkari

    2016-01-14

    This apparatus and method for applying a linerless label to an end user product includes a device with a printer for printing on a face surface of a linerless label, and a release coat applicator for applying a release coat to the face surface of the label; another device including an unwinder unit (103) to unwind a roll of printed linerless label; a belt (108); a glue applicator (102) for applying glue to the belt; a nip roller (106) for contacting and applying pressure to the face surface of the linerless label such that the glue on the belt transfers to the back surface of the linerless label; at least one slitting knife 105) positioned downstream the belt and a rewinder unit (104) positioned downstream the slitting knife; and a third device which die cuts and applies the linerless label to an end user object.

  5. Coronary Artery and Pulmonary Artery Fistula Originated from Significant Stenosis in the Left Anterior Descending Artery

    Directory of Open Access Journals (Sweden)

    Alper Sami Kunt

    2013-01-01

    Full Text Available Coronary artery fistula (CAF is defined as a rare anomalous connection between a coronary artery and a major vessel or a cardiac chamber. We report a case of a left anterior descending coronary (LAD stenosis and coronary artery fistula between the LAD coronary artery and the pulmonary artery (PA. CAF is often diagnosed by coronary angiogram. We describe our diagnostic approach and review the literature on the epidemiology, the pathophysiology, the diagnostic modalities, and the treatment options.

  6. To Spin or Not to Spin?

    Institute of Scientific and Technical Information of China (English)

    Tina Boikos

    2008-01-01

    @@ The alarm has just gone off. Do I really have to get up? I wonder. Originally, signing up for an early-morning spinning class seemed like a good idea; it jump-starts the day with some well-needed exercise.

  7. Explicit Spin Coordinates

    CERN Document Server

    Hunter, G; Hunter, Geoffrey; Schlifer, Ian

    2005-01-01

    The recently established existence of spherical harmonic functions, $Y_\\ell^{m}(\\theta,\\phi)$ for half-odd-integer values of $\\ell$ and $m$, allows for the introduction into quantum chemistry of explicit electron spin-coordinates; i.e. spherical polar angles $\\theta_s, \\phi_s$, that specify the orientation of the spin angular momentum vector in space. In this coordinate representation the spin angular momentum operators, $S^2, S_z$, are represented by the usual differential operators in spherical polar coordinates (commonly used for $L^2, L_z$), and their electron-spin eigenfunctions are $\\sqrt{\\sin\\theta_s} \\exp(\\pm\\phi_s/2)$. This eigenfunction representation has the pedagogical advantage over the abstract spin eigenfunctions, $\\alpha, \\beta,$ that ``integration over spin coordinates'' is a true integration (over the angles $\\theta_s, \\phi_s$). In addition they facilitate construction of many electron wavefunctions in which the electron spins are neither parallel nor antiparallel, but inclined at an interme...

  8. SPIN Tutorial: How to Become a SPIN Doctor

    NARCIS (Netherlands)

    Ruys, T.C.; Bosnacki, D.; Leue, S.

    2002-01-01

    SPIN is a model checker for the verification of software systems. SPIN uses a high level language called PROMELA to specify systems descriptions. The goal of this tutorial is to introduce novice users to both PROMELA and SPIN. The tutorial itself is divided into two parts. The BASIC SPIN part is tar

  9. Representation of Spin Group Spin(p, q)

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The representation (&)(p, q) of spin group Spin(p, q) in any dimensional space is given by induction, and the relation between two representations, which are obtained in two kinds of inductions from Spin(p, q) to Spin(p + 1, q + 1)are studied.

  10. Spin drift and spin diffusion currents in semiconductors

    Directory of Open Access Journals (Sweden)

    M Idrish Miah

    2008-01-01

    Full Text Available On the basis of a spin drift-diffusion model, we show how the spin current is composed and find that spin drift and spin diffusion contribute additively to the spin current, where the spin diffusion current decreases with electric field while the spin drift current increases, demonstrating that the extension of the spin diffusion length by a strong field does not result in a significant increase in spin current in semiconductors owing to the competing effect of the electric field on diffusion. We also find that there is a spin drift-diffusion crossover field for a process in which the drift and diffusion contribute equally to the spin current, which suggests a possible method of identifying whether the process for a given electric field is in the spin drift or spin diffusion regime. Spin drift-diffusion crossover fields for GaAs are calculated and are found to be quite small. We derive the relations between intrinsic spin diffusion length and the spin drift-diffusion crossover field of a semiconductor for different electron statistical regimes. The findings resulting from this investigation might be important for semiconductor spintronics.

  11. Radio labeling with pre-assigned frequencies

    NARCIS (Netherlands)

    Bodlaender, H.L.; Broersma, H.J.; Fomin, F.V.; Pyatkin, A.V.; Woeginer, G.J.

    2007-01-01

    A radio labeling of a graph G is an assignment of pairwise distinct, positive integer labels to the vertices of G such that labels of adjacent vertices differ by at least 2. The radio labeling problem (RL) consists in determining a radio labeling that minimizes the maximum label that is used (the so

  12. Towards Multi Label Text Classification through Label Propagation

    Directory of Open Access Journals (Sweden)

    Shweta C. Dharmadhikari

    2012-06-01

    Full Text Available Classifying text data has been an active area of research for a long time. Text document is multifaceted object and often inherently ambiguous by nature. Multi-label learning deals with such ambiguous object. Classification of such ambiguous text objects often makes task of classifier difficult while assigning relevant classes to input document. Traditional single label and multi class text classification paradigms cannot efficiently classify such multifaceted text corpus. Through our paper we are proposing a novel label propagation approach based on semi supervised learning for Multi Label Text Classification. Our proposed approach models the relationship between class labels and also effectively represents input text documents. We are using semi supervised learning technique for effective utilization of labeled and unlabeled data for classification. Our proposed approach promises better classification accuracy and handling of complexity and elaborated on the basis of standard datasets such as Enron, Slashdot and Bibtex.

  13. Spin transfer torque with spin diffusion in magnetic tunnel junctions

    KAUST Repository

    Manchon, Aurelien

    2012-08-09

    Spin transport in magnetic tunnel junctions in the presence of spin diffusion is considered theoretically. Combining ballistic tunneling across the barrier and diffusive transport in the electrodes, we solve the spin dynamics equation in the metallic layers. We show that spin diffusion mixes the transverse spin current components and dramatically modifies the bias dependence of the effective spin transfer torque. This leads to a significant linear bias dependence of the out-of-plane torque, as well as a nonconventional thickness dependence of both spin torque components.

  14. Spin transition in [Fe

    Science.gov (United States)

    Garcia, Y.; Ksenofontov, V.; Campbell, S. J.; Lord, J. S.; Boland, Y.; Gütlich, P.

    2004-12-01

    The reversible thermal spin transition which occurs in [Fe(phen)2(NCS)2] around T1/2 177 K has been investigated by muon spin relaxation (μSR) (10-280 K). The depolarisation curves are well described by two Lorentzian lines represent fast and slow components in the decay curves, with the initial asymmetry parameter of the fast component found to track the spin transition in [Fe(phen)2(NCS)2]. Comparison of zero-field and transverse field (20 Oe) μSR measurements shows that diamagnetic muonic species occur over the entire temperature range.

  15. Frustrated spin systems

    CERN Document Server

    2013-01-01

    This book covers all principal aspects of currently investigated frustrated systems, from exactly solved frustrated models to real experimental frustrated systems, going through renormalization group treatment, Monte Carlo investigation of frustrated classical Ising and vector spin models, low-dimensional systems, spin ice and quantum spin glass. The reader can - within a single book - obtain a global view of the current research development in the field of frustrated systems.This new edition is updated with recent theoretical, numerical and experimental developments in the field of frustrated

  16. Quantum Spin Hall Effect

    Energy Technology Data Exchange (ETDEWEB)

    Bernevig, B.Andrei; Zhang, Shou-Cheng; /Stanford U., Phys. Dept.

    2010-01-15

    The quantum Hall liquid is a novel state of matter with profound emergent properties such as fractional charge and statistics. Existence of the quantum Hall effect requires breaking of the time reversal symmetry caused by an external magnetic field. In this work, we predict a quantized spin Hall effect in the absence of any magnetic field, where the intrinsic spin Hall conductance is quantized in units of 2 e/4{pi}. The degenerate quantum Landau levels are created by the spin-orbit coupling in conventional semiconductors in the presence of a strain gradient. This new state of matter has many profound correlated properties described by a topological field theory.

  17. Correlation Functions and Spin

    CERN Document Server

    Tyc, T

    2000-01-01

    The k-electron correlation function of a free chaotic electron beam is derived with the spin degree of freedom taken into account. It is shown that it can be expressed with the help of correlation functions for a polarized electron beam of all orders up to k and the degree of spin polarization. The form of the correlation function suggests that if the electron beam is not highly polarized, observing multi-particle correlations should be difficult. The result can be applied also to chaotic photon beams, the degree of spin polarization being replaced by the degree of polarization.

  18. Spins in chemistry

    CERN Document Server

    McWeeny, Roy

    2004-01-01

    Originally delivered as a series of lectures, this volume systematically traces the evolution of the ""spin"" concept from its role in quantum mechanics to its assimilation into the field of chemistry. Author Roy McWeeny presents an in-depth illustration of the deductive methods of quantum theory and their application to spins in chemistry, following the path from the earliest concepts to the sophisticated physical methods employed in the investigation of molecular structure and properties. Starting with the origin and development of the spin concept, the text advances to an examination of sp

  19. Method for estimating spin-spin interactions from magnetization curves

    Science.gov (United States)

    Tamura, Ryo; Hukushima, Koji

    2017-02-01

    We develop a method to estimate the spin-spin interactions in the Hamiltonian from the observed magnetization curve by machine learning based on Bayesian inference. In our method, plausible spin-spin interactions are determined by maximizing the posterior distribution, which is the conditional probability of the spin-spin interactions in the Hamiltonian for a given magnetization curve with observation noise. The conditional probability is obtained with the Markov chain Monte Carlo simulations combined with an exchange Monte Carlo method. The efficiency of our method is tested using synthetic magnetization curve data, and the results show that spin-spin interactions are estimated with a high accuracy. In particular, the relevant terms of the spin-spin interactions are successfully selected from the redundant interaction candidates by the l1 regularization in the prior distribution.

  20. Screening asymptomatic patients with diabetes for unknown coronary artery disease: Does it reduce risk? An open-label randomized trial comparing a strategy based on exercise testing aimed at revascularization with management based on pharmacological/behavioural treatment of traditional risk factors. DADDY-D Trial (Does coronary Atherosclerosis Deserve to be Diagnosed and treated early in Diabetics?

    Directory of Open Access Journals (Sweden)

    Romano Stefania

    2009-12-01

    Full Text Available Abstract Background Coronary artery disease is the leading cause of morbidity and mortality in patients with type 2 diabetes. Screening for asymptomatic coronary artery disease with treatment by means of revascularization seems to be an appealing option for prevention. The utility of such a strategy has never been challenged in a randomized trial. Methods/Design In the present study a cohort of diabetic patients without any symptoms and without known coronary artery disease will be screened at two diabetes outpatients services. Those with intermediate or high risk (equal or greater than 10% according to the Italian risk chart will be asked to participate and enrolled. They will be seen and followed in order to provide the best adherence to medical therapy. Half of the patients will be randomized to undergo an exercise tolerance testing while the other group will continue to be regularly seen at diabetes outpatients services. Best medical/behavioral therapy will be offered to both groups. Those patients with a positive exercise tolerance testing will be studied by coronary angiography and treated according to the severity of coronary lesions by percutaneous stenting or surgery. The objective of the study is to evaluate the efficacy of the screening strategy aimed at revascularization. A cost-effectiveness analysis will be performed at the end of the follow up. Discussion The study will provide useful information about prevention and treatment of diabetic patients at high risk of coronary events. It will be made clearer if detection of silent coronary artery disease has to be recommended and followed by treatment. Given the simplicity of the study protocol, it will be easily transferable to the real world. Trial registration (ClinicalTrials.gov: NCT00547872

  1. Spin pumping and inverse spin Hall effects—Insights for future spin-orbitronics (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei, E-mail: zwei@anl.gov; Jungfleisch, Matthias B.; Jiang, Wanjun; Fradin, Frank Y.; Pearson, John E.; Hoffmann, Axel, E-mail: hoffmann@anl.gov [Materials Science Division, Argonne National Laboratory, Lemont, Illinois 60439 (United States); Sklenar, Joseph; Ketterson, John B. [Department of Physics and Astronomy, Northwestern University, Evanston, Illinois 60208 (United States)

    2015-05-07

    Quantification of spin-charge interconversion has become increasingly important in the fast-developing field of spin-orbitronics. Pure spin current generated by spin pumping acts as a sensitive probe for many bulk and interface spin-orbit effects, which has been indispensable for the discovery of many promising new spin-orbit materials. We apply spin pumping and inverse spin Hall effect experiments, as a useful metrology, and study spin-orbit effects in a variety of metals and metal interfaces. We quantify the spin Hall effects in Ir and W using the conventional bilayer structures and discuss the self-induced voltage in a single layer of ferromagnetic permalloy. Finally, we extend our discussions to multilayer structures and quantitatively reveal the spin current flow in two consecutive normal metal layers.

  2. Left Coronary Artery-Pulmonary Artery Fistula in Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Orhan Veli Doğan

    2012-08-01

    Full Text Available Coroner artery fistula which is rare and congenital or acquired arise from whole coroner artery drainage all of cardiac chamber and great artery. Although coroner artery fistula is uncommon, it can cause significant mortality and morbidity rates. The article is presented which coroner artery disease and coroner-pulmonary artery fistula was accomplishment committed. Sixty three year-old male patient admitted to the hospital with chest pain. Non-ST myocardial infarction was diagnosed in the examinations. After coroner angiography, it was found coronary artery disease in addition between LAD proximal portion and main pulmonary artery fistula. Fistula repair and coronary bypass were performed successfully under cardiopulmonary bypass. Without hemodynamic problem in intensive care and service follow-up, the patient was discharged from the hospital in the seventh postoperative day. We think that surgical treatment of coronary fistulas in patients with coronary artery lesion is done at the earliest time would enable improvement in mortality and morbidity rates.

  3. 78 FR 66826 - Prior Label Approval System: Generic Label Approval

    Science.gov (United States)

    2013-11-07

    ... submitted for evaluation and approval before use under the final rule are: (1) Labels for chicken produced..., such as ``no antibiotics administered'' or ``vegetarian fed''; (4) instructional or...

  4. Iodine-125 metaraminol: A new platelet specific labeling agent

    Energy Technology Data Exchange (ETDEWEB)

    Ohmomo, Y.; Yokoyama, A.; Kawaii, K.; Horiuchi, K.; Saji, H.; Torizuka, K.

    1984-01-01

    In the search for a platelet specific labeling agent, Metaraminol (MA), which is a sympatomimetic amine used for the treatment of hypotension, cardiogenic shock and well recognized as a drug actively incorporated and accumulated in platelet, attracted the authors' attention. Using the classical chloramine-T iodination method, a high labeling efficiency near 98%, reaching a specific activity up to about 1000 Ci/mmole was obtained. Upon the harvest of platelet, only as platelet rich plasma (PRP), the labeling with this radiopharmaceutical was easily performed by incubation at 37/sup 0/C for 10 min. Labeling efficiency as high as 63.0 +- 3.1% at 24 x 10/sup 8/ cells/ml was obtained. In in-vitro studies, the unaltered state of I-125 MA labeled platelet, with their cellular functions fully retained was demonstrated. Pharmacological study indicated a specific incorporation of I-125 MA by active transport system similar to that of 5-HT, along with passive diffusion. Then the in-vivo study carried out in rabbits with induced thrombi on the femoral artery, showed rather rapid disappearance of the I-125 MA labeled autologous platelet radioactivity, from circulating blood reaching as high thrombus-to-blood activity ratio as 19.8+-4.3 within 30 min post-administration. This new platelet labeling agent, I-125 MA, has many advantages over the use of IN-111 oxine and holds considerable promise for thrombus imaging with single photon emission CT upon the availability of I-123 MA.

  5. Arterial hypertension and cancer.

    Science.gov (United States)

    Milan, Alberto; Puglisi, Elisabetta; Ferrari, Laura; Bruno, Giulia; Losano, Isabel; Veglio, Franco

    2014-05-15

    Arterial hypertension and cancer are two of the most important causes of mortality in the world; correlations between these two clinical entities are complex and various. Cancer therapy using old (e.g., mitotic spindle poisons) as well as new (e.g., monoclonal antibody) drugs may cause arterial hypertension through different mechanisms; sometimes the increase of blood pressure levels may be responsible for chemotherapy withdrawal. Among newer cancer therapies, drugs interacting with the VEGF (vascular endothelial growth factors) pathways are the most frequently involved in hypertension development. However, many retrospective studies have suggested a relationship between antihypertensive treatment and risk of cancer, raising vast public concern. The purposes of this brief review have then been to analyse the role of chemotherapy in the pathogenesis of hypertension, to summarize the general rules of arterial hypertension management in this field and finally to evaluate the effects of antihypertensive therapy on cancer disease.

  6. ANALYSIS ON THE SPINNING FORCES IN FLEXIBLE SPINNING OF CONES

    Institute of Scientific and Technical Information of China (English)

    Xia Qinxiang; Susumu Shima

    2003-01-01

    Flexible spinning is a new type of spinning process where spin-forming is performed without using a mandrel. Combining shearing and rolling processes, the calculation formulas of thespinning forces in flexible spinning of cones is presented. The effects of the main processing parameters, such as gripping force G applied to the blank by the inner roller, the feed rate of rollersfand the roundness radius of outer roller ro, on the spinning forces are analyzed experimentally and theoretically.

  7. Combined arterial and venous whole-body MR angiography with cardiac MR imaging in patients with thromboembolic disease - initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, Florian M.; Hunold, Peter; Barkhausen, Joerg [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Herborn, Christoph U. [University Hospital Hamburg-Eppendorf, Medical Prevention Center Hamburg (MPCH) at University Hospital Hamburg-Eppendorf, Hamburg (Germany); Ruehm, Stefan G. [David Geffen School of Medicine at UCLA, Department of Radiology, Los Angeles, CA (United States); Kroger, Knut [University Hospital Essen, Department of Angiology, Essen (Germany)

    2008-05-15

    The objective was to assess the feasibility of a combined arterial and venous whole-body three-dimensional magnetic resonance (MR) angiography, together with a cardiac MR examination, in patients with arterial thromboembolism. Ten patients with arterial thromboembolism underwent a contrast-enhanced whole-body MR examination of the arterial and venous vessels, followed by a cardiac MR examination on a separate occasion within 24 h. All examinations were performed on a 1.5-T MR scanner. For both arterial and venous MR angiography only one injection of contrast agent was necessary. The cardiac imaging protocol included dark-blood-prepared half-Fourier acquisition single-shot turbo-spin-echo sequences, fast steady-state free precession cine sequences, T2-weighted turbo-spin-echo sequences and inversion recovery gradient-echo fast low-angle-shot sequences after injection of contrast agent. MR imaging revealed additional clinically unknown arterial thromboembolisms in four patients. The thoracic aorta was depicted as embolic source in four patients, while deep vein thrombosis (DVT) was found in one patient as the underlying disease. Unsuspected infarction of parenchymal organs was detected by MRI in two patients. An unknown additional DVT was found in one patient. Four patients were considered to have arterial emboli of cardiac origin. In conclusion, acquisition of arterial and venous MR angiograms of the entire vascular system combined with cardiac MR imaging is a most comprehensive and valuable strategy in patients with arterial thromboembolism. (orig.)

  8. International Spin Physics 2014 Summary

    CERN Document Server

    Milner, Richard G

    2015-01-01

    The Stern-Gerlach experiment and the origin of electron spin are described in historical context. SPIN 2014 occurs on the fortieth anniversary of the first International High Energy Spin Physics Symposium at Argonne in 1974. A brief history of the international spin conference series is presented.

  9. On Nonlinear Higher Spin Curvature

    OpenAIRE

    Manvelyan, Ruben(Yerevan Physics Institute, Alikhanian Br. St. 2, Yerevan, 0036, Armenia); Mkrtchyan, Karapet; Rühl, Werner; Tovmasyan, Murad

    2011-01-01

    We present the first nonlinear term of the higher spin curvature which is covariant with respect to deformed gauge transformations that are linear in the field. We consider in detail the case of spin 3 after presenting spin 2 as an example, and then construct the general spin s quadratic term of the deWit-Freedman curvature.

  10. On nonlinear higher spin curvature

    Energy Technology Data Exchange (ETDEWEB)

    Manvelyan, Ruben, E-mail: manvel@physik.uni-kl.d [Department of Physics, Erwin Schroedinger Strasse, Technical University of Kaiserslautern, Postfach 3049, 67653 Kaiserslautern (Germany); Yerevan Physics Institute, Alikhanian Br. Str. 2, 0036 Yerevan (Armenia); Mkrtchyan, Karapet, E-mail: karapet@yerphi.a [Department of Physics, Erwin Schroedinger Strasse, Technical University of Kaiserslautern, Postfach 3049, 67653 Kaiserslautern (Germany); Yerevan Physics Institute, Alikhanian Br. Str. 2, 0036 Yerevan (Armenia); Ruehl, Werner, E-mail: ruehl@physik.uni-kl.d [Department of Physics, Erwin Schroedinger Strasse, Technical University of Kaiserslautern, Postfach 3049, 67653 Kaiserslautern (Germany); Tovmasyan, Murad, E-mail: mtovmasyan@ysu.a [Yerevan Physics Institute, Alikhanian Br. Str. 2, 0036 Yerevan (Armenia)

    2011-05-09

    We present the first nonlinear term of the higher spin curvature which is covariant with respect to deformed gauge transformations that are linear in the field. We consider the case of spin 3 after presenting spin 2 as an example, and then construct the general spin s quadratic term of the de Wit-Freedman curvature.

  11. Parallel cluster labeling for large-scale Monte Carlo simulations

    CERN Document Server

    Flanigan, M; Flanigan, M; Tamayo, P

    1995-01-01

    We present an optimized version of a cluster labeling algorithm previously introduced by the authors. This algorithm is well suited for large-scale Monte Carlo simulations of spin models using cluster dynamics on parallel computers with large numbers of processors. The algorithm divides physical space into rectangular cells which are assigned to processors and combines a serial local labeling procedure with a relaxation process across nearest-neighbor processors. By controlling overhead and reducing inter-processor communication this method attains good computational speed-up and efficiency. Large systems of up to 65536 X 65536 spins have been simulated at updating speeds of 11 nanosecs/site (90.7 million spin updates/sec) using state-of-the-art supercomputers. In the second part of the article we use the cluster algorithm to study the relaxation of magnetization and energy on large Ising models using Swendsen-Wang dynamics. We found evidence that exponential and power law factors are present in the relaxatio...

  12. Microscopic studies of nonlocal spin dynamics and spin transport (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Adur, Rohan; Du, Chunhui; Cardellino, Jeremy; Scozzaro, Nicolas; Wolfe, Christopher S.; Wang, Hailong; Herman, Michael; Bhallamudi, Vidya P.; Pelekhov, Denis V.; Yang, Fengyuan; Hammel, P. Chris, E-mail: hammel@physics.osu.edu [Department of Physics, The Ohio State University, Columbus, Ohio 43210 (United States)

    2015-05-07

    Understanding the behavior of spins coupling across interfaces in the study of spin current generation and transport is a fundamental challenge that is important for spintronics applications. The transfer of spin angular momentum from a ferromagnet into an adjacent normal material as a consequence of the precession of the magnetization of the ferromagnet is a process known as spin pumping. We find that, in certain circumstances, the insertion of an intervening normal metal can enhance spin pumping between an excited ferromagnetic magnetization and a normal metal layer as a consequence of improved spin conductance matching. We have studied this using inverse spin Hall effect and enhanced damping measurements. Scanned probe magnetic resonance techniques are a complementary tool in this context offering high resolution magnetic resonance imaging, localized spin excitation, and direct measurement of spin lifetimes or damping. Localized magnetic resonance studies of size-dependent spin dynamics in the absence of lithographic confinement in both ferromagnets and paramagnets reveal the close relationship between spin transport and spin lifetime at microscopic length scales. Finally, detection of ferromagnetic resonance of a ferromagnetic film using the photoluminescence of nitrogen vacancy spins in neighboring nanodiamonds demonstrates long-range spin transport between insulating materials, indicating the complexity and generality of spin transport in diverse, spatially separated, material systems.

  13. Microscopic studies of nonlocal spin dynamics and spin transport (invited)

    Science.gov (United States)

    Adur, Rohan; Du, Chunhui; Cardellino, Jeremy; Scozzaro, Nicolas; Wolfe, Christopher S.; Wang, Hailong; Herman, Michael; Bhallamudi, Vidya P.; Pelekhov, Denis V.; Yang, Fengyuan; Hammel, P. Chris

    2015-05-01

    Understanding the behavior of spins coupling across interfaces in the study of spin current generation and transport is a fundamental challenge that is important for spintronics applications. The transfer of spin angular momentum from a ferromagnet into an adjacent normal material as a consequence of the precession of the magnetization of the ferromagnet is a process known as spin pumping. We find that, in certain circumstances, the insertion of an intervening normal metal can enhance spin pumping between an excited ferromagnetic magnetization and a normal metal layer as a consequence of improved spin conductance matching. We have studied this using inverse spin Hall effect and enhanced damping measurements. Scanned probe magnetic resonance techniques are a complementary tool in this context offering high resolution magnetic resonance imaging, localized spin excitation, and direct measurement of spin lifetimes or damping. Localized magnetic resonance studies of size-dependent spin dynamics in the absence of lithographic confinement in both ferromagnets and paramagnets reveal the close relationship between spin transport and spin lifetime at microscopic length scales. Finally, detection of ferromagnetic resonance of a ferromagnetic film using the photoluminescence of nitrogen vacancy spins in neighboring nanodiamonds demonstrates long-range spin transport between insulating materials, indicating the complexity and generality of spin transport in diverse, spatially separated, material systems.

  14. Idiopathic pulmonary artery aneurysm.

    Science.gov (United States)

    Kotwica, Tomasz; Szumarska, Joanna; Staniszewska-Marszalek, Edyta; Mazurek, Walentyna; Kosmala, Wojciech

    2009-05-01

    Pulmonary artery aneurysm (PAA) is an uncommon lesion, which may be associated with different etiologies including congenital cardiovascular diseases, systemic vasculitis, connective tissue diseases, infections, and trauma. Idiopathic PAA is sporadically diagnosed by exclusion of concomitant major pathology. We report a case of a 56-year-old female with an idiopathic pulmonary artery dilatation identified fortuitously by echocardiography and confirmed by contrast-enhanced computed tomography. Neither significant pulmonary valve dysfunction nor pulmonary hypertension and other cardiac abnormalities which might contribute to the PAA development were found. Here, we describe echocardiographic and computed tomography findings and review the literature on PAA management.

  15. Left Anterior Descending Artery-Pulmonary Artery Fistula

    Directory of Open Access Journals (Sweden)

    Turan Ege

    2011-12-01

    Full Text Available Despite the fact that coronary arteriovenous fistulas constitute approximately half (48% of coronary artery anomalies, they are rarely seen anomalies. In this report,we aim to present a coronary arteriovenous fistula case detected during a coronary angiography between left anterior descending artery and pulmonary artery.

  16. Pulmonary arterial hypertension in children after neonatal arterial switch operation

    NARCIS (Netherlands)

    Zijlstra, Willemijn Mh; Elmasry, Ola; Pepplinkhuizen, Shari; Ivy, D Dunbar; Bonnet, Damien; Lévy, Marilyne; Gavilan, Jose Luis; Torrent-Vernetta, Alba; Mendoza, Alberto; Del Cerro, Maria Jesus; Moledina, Shahin; Berger, Rolf M. F.

    2017-01-01

    OBJECTIVES: Paediatric pulmonary arterial hypertension (PAH) after neonatal arterial switch operation (ASO) for transposition of the great arteries (TGA) is a clinically recognised entity with an estimated incidence of 0.6%-1.0%. Nevertheless, a clinical characterisation is lacking. We present an in

  17. Coherent manipulation of single electron spins with Landau-Zener sweeps

    Science.gov (United States)

    Rančić, Marko J.; Stepanenko, Dimitrije

    2016-12-01

    We propose a method to manipulate the state of a single electron spin in a semiconductor quantum dot (QD). The manipulation is achieved by tunnel coupling a QD, labeled L , and occupied with an electron to an adjacent QD, labeled R , which is not occupied by an electron but having an energy linearly varying in time. We identify a parameter regime in which a complete population transfer between the spin eigenstates |L ↑> and |L ↓> is achieved without occupying the adjacent QD. This method is convenient due to the fact that manipulation can be done electrically, without precise knowledge of the spin resonance condition, and is robust against Zeeman level broadening caused by nuclear spins.

  18. GEO label: The General Framework for Labeling and Certification

    Science.gov (United States)

    Bye, B. L.; McCallum, I.; Maso, J.

    2012-04-01

    The Group on Earth Observations (GEO) is coordinating efforts to build a Global Earth Observation System of Systems, or GEOSS. As part of a strategy to increase the involvement of the science and technology community in GEOSS, both as users and developers of GEOSS itself, GEO decided to develop a GEO label concept related to the scientific relevance, quality, acceptance and societal needs for services and data sets of GEOSS. The development of a GEO label is included in the GEO work plan and several projects address the challenges of developing a GEO label concept. Within the different projects developing the GEO label, various perspectives and approaches are being applied. In order to arrive at a generally accepted GEO label concept, a common understanding and basic knowledge of labeling is necessary. Assessment of quality of internationally standardized Earth observation data products implies possible certification. A general understanding of the framework for international standards and certification will also contribute to a more coherent discussion and more efficient development of a GEO label. We will describe the general labeling and certification framework emphasizing the relation to the three elements of the GEO label: quality, user acceptance and relevance. Based on a survey of international labels done by the EGIDA project, we have analyzed the legal framework and organization of labels and certification. We will discuss the frameworks for certification, user ratings, registration and analysis of user requirements. Quality assessment is a particular focus of the analysis and is based on the work done by the GeoViQua project. A GEO label will function both as a data distribution strategy and as a general management system for data. Through a label users can compare different data sets and get access to more information about the relevant data, including quality. A label will provide traceability of data both in the interest of users as well as data

  19. Litter-Spinning Retarders

    Science.gov (United States)

    Wilson, John C.

    1995-01-01

    Aerodynamic plates stop litter from spinning during hoisting by helicopter. Features of proposed litter-spinning retarders include convenience of deployment and independence from ground restraint. Retarder plate(s) folded flat against bottom of litter during storage or while litter is loaded. Plate(s) held in storage position by latch that releases manually or automatically as litter is hoisted. Upon release, springs move plates into deployed position.

  20. Spin polarizability of hyperons

    Indian Academy of Sciences (India)

    K B Vijaya Kumar

    2014-11-01

    We review the recent progress of the theoretical understanding of spin polarizabilities of the hyperon in the framework of (3) heavy baryon chiral perturbation theory (HBChPT). We present the results of a systematic leading-order calculation of hyperon Compton scattering and extract the forward spin polarizability (0) of hyperons. The results obtained for $_0$ in the case of nucleons agree with the known results of (2) HBChPT when kaon loops are not considered.

  1. Cardiopulmonary fitness correlates with regional cerebral grey matter perfusion and density in men with coronary artery disease.

    Directory of Open Access Journals (Sweden)

    Bradley J MacIntosh

    Full Text Available PURPOSE: Physical activity is associated with positive effects on the brain but there is a paucity of clinical neuroimaging data in patients with coronary artery disease (CAD, a cardiovascular condition associated with grey matter loss. The purpose of this study was to determine which brain regions are impacted by cardiopulmonary fitness and with the change in fitness after 6 months of exercise-based cardiac rehabilitation. METHODS: CAD patients underwent magnetic resonance imaging at baseline, and peak volume of oxygen uptake during exercise testing (VO2Peak was measured at baseline and after 6 months of training. T1-weighted structural images were used to perform grey matter (GM voxel-based morphometry (VBM. Pseudo-continuous arterial spin labeling (pcASL was used to produce cerebral blood flow (CBF images. VBM and CBF data were tested voxel-wise using VO2Peak and age as explanatory variables. RESULTS: In 30 men with CAD (mean age 65±7 years, VBM and CBF identified 7 and 5 respective regions positively associated with baseline VO2Peak. These included the pre- and post-central, paracingulate, caudate, hippocampal regions and converging findings in the putamen. VO2Peak increased by 20% at follow-up in 29 patients (t = 9.6, df = 28, p<0.0001. Baseline CBF in the left post-central gyrus and baseline GM density in the right putamen predicted greater change in VO2Peak. CONCLUSION: Perfusion and GM density were associated with fitness at baseline and with greater fitness gains with exercise. This study identifies new neurobiological correlates of fitness and demonstrates the utility of multi-modal MRI to evaluate the effects of exercise in CAD patients.

  2. Spin transport in nanoscale spin valves and magnetic tunnel junctions

    Science.gov (United States)

    Patibandla, Sridhar

    Spintronics or electronics that utilizes the spin degree of freedom of a single charge carrier (or an ensemble of charge carriers) to store, process, sense or communicate data and information is a rapidly burgeoning field in electronics. In spintronic devices, information is encoded in the spin polarization of a single carrier (or multiple carriers) and the spin(s) of these carrier(s) are manipulated for device operation. This strategy could lead to devices with low power consumption. This dissertation investigates spin transport in one dimensional and two dimensional semiconductors, with a view to applications in spintronic devices. This dissertation is arranged as follows: Chapter 1 gives a detailed introduction and necessary background to understand aspects of spin injection into a semiconductor from a spin polarized source such as a ferromagnet, and spin polarized electron transport in the semiconductor. Chapter 2 discusses the nanoporous alumina technique that is employed to fabricate nanowires and nanowire spin valves for the investigation of spin transport in 1D semiconductors. Chapter 3 investigates the spin transport in quasi one-dimensional spin valves with germanium spacer layer. These spin valves with 50nm in diameter and 1 mum length were fabricated using the porous alumina technique. Spin transport in nanoscale germanium spin valves was demonstrated and the spin relaxation lengths and the spin relaxation times were calculated. Chapter 4 discusses spin transport studies conducted in bulk high purity germanium with a view to comparing spin relaxation mechanisms in low mobility nanowires and high mobility bulk structures. Lateral spin valve with tunnel injectors were employed in this study and the spin transport measurements were conducted at various temperatures. The spin relaxation rates were measured as a function of temperature which allowed us to distinguish between two different mechanisms---D'yakonov-Perel' and Elliott-Yafet---that dominate spin

  3. Pharmacological modulation of arterial stiffness.

    LENUS (Irish Health Repository)

    Boutouyrie, Pierre

    2011-09-10

    Arterial stiffness has emerged as an important marker of cardiovascular risk in various populations and reflects the cumulative effect of cardiovascular risk factors on large arteries, which in turn is modulated by genetic background. Arterial stiffness is determined by the composition of the arterial wall and the arrangement of these components, and can be studied in humans non-invasively. Age and distending pressure are two major factors influencing large artery stiffness. Change in arterial stiffness with drugs is an important endpoint in clinical trials, although evidence for arterial stiffness as a therapeutic target still needs to be confirmed. Drugs that independently affect arterial stiffness include antihypertensive drugs, mostly blockers of the renin-angiotensin-aldosterone system, hormone replacement therapy and some antidiabetic drugs such as glitazones. While the quest continues for \\'de-stiffening drugs\\

  4. Sustainability labels on food products

    DEFF Research Database (Denmark)

    Grunert, Klaus G; Hieke, Sophie; Wills, Josephine

    2014-01-01

    This study investigates the relationship between consumer motivation, understanding and use of sustainability labels on food products (both environmental and ethical labels), which are increasingly appearing on food products. Data was collected by means of an online survey implemented in the UK......, human values as measured by the Schwartz value domains, and country differences. The results imply that sustainability labels currently do not play a major role in consumers’ food choices, and future use of these labels will depend on the extent to which consumers’ general concern about sustainability...

  5. Pulmonary artery sling: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Gil Hyun; Lee, Sun Wha; Cha, Sung Ho [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    1993-09-15

    Aberrant left-sided pulmonary artery(pulmonary artery sling) is an uncommon anomaly,which may cause significant respiratory abnormality. We report a case of pulmonary artery sling which is combined with persistent left superior vena cava and dextrocardia. This case were identified by esophagogram and CT and confirmed by MRI and angiography. We consider that MRI is a valuable new method for the diagnosis of aberrant left-sided pulmonary artery.

  6. 76 FR 75809 - Prior Label Approval System: Generic Label Approval

    Science.gov (United States)

    2011-12-05

    ... Food Standards and Labeling Policy Book; does not bear any special claims, such as quality claims... addition, deletion, or amendment of recipe suggestions for the product; j. Any change in punctuation; k... Policy Book, and questions and answers on various topics, such as irradiation and the labeling...

  7. Cern News The Higgs or not the Higgs. Spin will tell. Part 2

    CERN Multimedia

    CERN Visual Media Office; Paola Catapano

    2012-01-01

    Second part of the videonews explaining why the newly found boson at the LHC cannot yet be labelled the Higgs boson and what is the spin of a particle. In this seconfd part, Higgs searches conveners Christopher Paus (CMS) and Aidan Randle (ATLAS) and theoretical physicist John Ellis provide the latest information on the spin of the presumed Higgs boson, on the already excluded values and the open questions.

  8. Spin Hall effect induced spin transfer through an insulator

    Science.gov (United States)

    Chen, Wei; Sigrist, Manfred; Manske, Dirk

    2016-09-01

    When charge current passes through a normal metal that exhibits the spin Hall effect, spin accumulates at the edge of the sample in the transverse direction. We predict that this spin accumulation, or spin voltage, enables quantum tunneling of spin through an insulator or vacuum to reach a ferromagnet without transferring charge. In a normal metal/insulator/ferromagnetic insulator trilayer (such as Pt/oxide/YIG), the quantum tunneling explains the spin-transfer torque and spin pumping that exponentially decay with the thickness of the insulator. In a normal metal/insulator/ferromagnetic metal trilayer (such as Pt/oxide/Co), the spin transfer in general does not decay monotonically with the thickness of the insulator. Combining with the spin Hall magnetoresistance, this tunneling mechanism points to the possibility of a tunneling spectroscopy that can probe the magnon density of states of a ferromagnetic insulator in an all-electrical and noninvasive manner.

  9. Spin photonics and spin-photonic devices with dielectric metasurfaces

    CERN Document Server

    Liu, Yachao; Ke, Yougang; Zhou, Xinxing; Luo, Hailu; Wen, Shuangchun

    2015-01-01

    Dielectric metasurfaces with spatially varying birefringence and high transmission efficiency can exhibit exceptional abilities for controlling the photonic spin states. We present here some of our works on spin photonics and spin-photonic devices with metasurfaces. We develop a hybrid-order Poincare sphere to describe the evolution of spin states of wave propagation in the metasurface. Both the Berry curvature and the Pancharatnam-Berry phase on the hybrid-order Poincare sphere are demonstrated to be proportional to the variation of total angular momentum. Based on the spin-dependent property of Pancharatnam-Berry phase, we find that the photonic spin Hall effect can be observed when breaking the rotational symmetry of metasurfaces. Moreover, we show that the dielectric metasurfaces can provide great flexibility in the design of novel spin-photonic devices such as spin filter and spin-dependent beam splitter.

  10. Intracranial artery dissection

    NARCIS (Netherlands)

    Sikkema, T.; Uyttenboogaart, Maarten; Eshghi, O.; De Keyser, J.; Brouns, R.; van Dijk, J.M.C.; Luijckx, G. J.

    2014-01-01

    The aim of this narrative review is to evaluate the pathogenesis, clinical features, diagnosis, treatment and prognosis of intracranial artery dissection (IAD). IAD is a rare and often unrecognized cause of stroke or subarachnoid haemorrhage (SAH), especially in young adults. Two types of IAD can be

  11. Popliteal artery entrapment syndrome

    DEFF Research Database (Denmark)

    Altintas, Ümit; Helgstrand, Ulf Johan Vilhelm; Hansen, Marc A;

    2013-01-01

    The purpose of this study was to report our experience with popliteal artery entrapment syndrome (PAES) with special emphasis on the applicability of duplex ultrasound scanning (DUS) when diagnosing PAES. In addition to examining the correlation between DUS and intraoperative findings...

  12. Arterial Emboli Complicating Cisplatin Therapy

    OpenAIRE

    Tait, Campbell D.; Rankin, Elaine M

    2012-01-01

    We report three cases of arterial emboli in patients with lung cancer treated with cisplatin chemotherapy. All three patients were managed without surgical intervention but subsequent oncological treatment was complicated by the sequelae of arterial emboli. We discuss the issues surrounding these patients and the importance of identifying patients at risk of arterial embolic phenomena with cisplatin treatment.

  13. Spin Torques in Systems with Spin Filtering and Spin Orbit Interaction

    KAUST Repository

    Ortiz Pauyac, Christian

    2016-06-19

    In the present thesis we introduce the reader to the field of spintronics and explore new phenomena, such as spin transfer torques, spin filtering, and three types of spin-orbit torques, Rashba, spin Hall, and spin swapping, which have emerged very recently and are promising candidates for a new generation of memory devices in computer technology. A general overview of these phenomena is presented in Chap. 1. In Chap. 2 we study spin transfer torques in tunnel junctions in the presence of spin filtering. In Chap. 3 we discuss the Rashba torque in ferromagnetic films, and in Chap. 4 we study spin Hall effect and spin swapping in ferromagnetic films, exploring the nature of spin-orbit torques based on these mechanisms. Conclusions and perspectives are summarized in Chap. 5.

  14. Quality Evaluation Model for Map Labeling

    Institute of Scientific and Technical Information of China (English)

    FAN Hong; ZHANG Zuxun; DU Daosheng

    2005-01-01

    This paper discusses and sums up the basic criterions of guaranteeing the labeling quality and abstracts the four basic factors including the conflict for a label with a label, overlay for label with the features, position's priority and the association for a label with its feature. By establishing the scoring system, a formalized four-factors quality evaluation model is constructed. Last, this paper introduces the experimental result of the quality evaluation model applied to the automatic map labeling system-MapLabel.

  15. Safety and effectiveness of a circumferential clip-based vascular closure device for hemostasis in off-label applications: Comparison with standard applications

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Chan; Kim, Chang Won [Dept. of Radiology, Pusan National University School of Medicine, Pusan National University Hospital, Busan (Korea, Republic of); Jeon, Ung Bae [Dept. of Radiology, Pusan National University School of Medicine, Yangsan Pusan National University Hospital, Yangsan (Korea, Republic of)

    2016-09-15

    We investigated the efficacy and safety of a circumferential nitinol clip based arterial closure device following arteriotomy, especially in off-label applications. Consecutive patients who underwent the procedure with arteriotomy from January 2011 to February 2014 were included in this study. We defined standard use as the use of StarClose for retrograde puncture of the common femoral artery (CFA) and off-label use as the use of StarClose for retrograde puncture of the superficial femoral artery (SFA), antegrade puncture of the CFA or SFA, puncture of the brachial artery or puncture of the vascular graft. The procedures performed included percutaneous transluminal angioplasty and thrombolysis. Technical success was defined as complete hemostasis achieved within 3 minute after the closure. Complications, and laboratory findings associated with coagulation function, were also investigated. There were 146 cases of standard applications and 111 cases of off-label applications. Technical success was achieved in all cases. The off-label group comprised the use of StarClose for retrograde puncture of the SFA (n = 19), antegrade puncture of the CFA or SFA (n = 74), brachial artery puncture (n = 5), larger sheath than 6 Fr (n = 7) and vascular graft puncture (n = 6). Minor complications were noted in both groups (standard group: 7.5%, off-label group: 2.7%). Off-label use of StarClose is safe and feasible.

  16. Cerebral Arterial Fenestrations

    Science.gov (United States)

    Cooke, Daniel L; Stout, Charles E; Kim, Warren T; Kansagra, Akash P; Yu, John Paul; Gu, Amy; Jewell, Nicholas P; Hetts, Steven W; Higashida, Randall T; Dowd, Christopher F; Halbach, Van V

    2014-01-01

    Summary Arterial fenestrations are an anatomic variant with indeterminate significance. Given the controversy surrounding fenestrations we sought their prevalence within our practice along with their association with other cerebrovascular anomalies. We retrospectively reviewed 10,927 patients undergoing digital subtraction angiography between 1992 and 2011. Dictated reports were searched for the terms “fenestration” or “fenestrated” with images reviewed for relevance, yielding 228 unique cases. A Medline database search from February 1964 to January 2013 generated 304 citations, 127 cases of which were selected for analysis. Cerebral arterial fenestrations were identified in 228 patients (2.1%). At least one aneurysm was noted in 60.5% of patients, with an aneurysm arising from the fenestration in 19.6% of patients. Aneurysmal subarachnoid hemorrhage or non-aneurysmal subarachnoid hemorrhage were present in 60.1% and 15.8%, respectively. For the subset of patients with an aneurysm arising directly from a fenestration relative to those patients with an aneurysm not immediately associated with a fenestration, the prevalence of aneurysmal subarachnoid hemorrhage was 66.7% vs. 58.6% (p = 0.58). Fenestrations were more often within the posterior circulation (73.2%) than the anterior circulation (24.6%), though there was no difference in the prevalence of aneurysms within these groups (61.1% vs. 60.7%, p = 1.0). Cerebral arterial fenestrations are an anatomic variant more often manifesting at the anterior communicating arterial complex and basilar artery and with no definite pathological relationship with aneurysms. PMID:24976087

  17. Magnetocaloric effect in quantum spin-s chains

    Directory of Open Access Journals (Sweden)

    A. Honecker

    2009-01-01

    Full Text Available We compute the entropy of antiferromagnetic quantum spin-s chains in an external magnetic field using exact diagonalization and Quantum Monte Carlo simulations. The magnetocaloric effect, i. e., temperature variations during adiabatic field changes, can be derived from the isentropes. First, we focus on the example of the spin-s=1 chain and show that one can cool by closing the Haldane gap with a magnetic field. We then move to quantum spin-s chains and demonstrate linear scaling with s close to the saturation field. In passing, we propose a new method to compute many low-lying excited states using the Lanczos recursion.

  18. Measuring blood oxygenation of pulsatile arteries using photoacoustic microscopy

    Science.gov (United States)

    Li, Qian; Yu, Tianhao; Li, Lin; Chai, Xinyu; Zhou, Chuanqing

    2016-10-01

    Heart pumps blood through the blood vessels to provide body with oxygen and nutrients. As the result, the blood flow, volume and oxygenation in arteries has a pulsatile nature. Measuring these pulsatile parameters enables more precise monitoring of oxygen metabolic rate and is thus valuable for researches and clinical applications. Photoacoustic microscopy (PAM) is a proven label-free method for in vivo measuring blood oxygenation at single blood vessel level. However, studies using PAM to observe the pulsatile nature of blood oxygenation in arteries were not reported. In this paper, we use optical-resolution PAM (OR-PAM) technology to study the blood oxygenation dynamics of pulsatile arteries. First, the ability of our OR-PAM system to accurately reflect the change of optical absorption in imaged objects is demonstrated in a phantom study. Then the system is used to image exposed cortical blood vessels of cat. The pulsatile nature of blood volume and oxygenation in arteries is clearly reflected in photoacoustic (PA) signals, whereas it's not observable in veins. By using a multi-wavelength laser, the dynamics of the blood oxygenation of pulsatile arteries in cardiac cycles can be measured, based on the spectroscopic method.

  19. Distance labeling schemes for trees

    DEFF Research Database (Denmark)

    Alstrup, Stephen; Gørtz, Inge Li; Bistrup Halvorsen, Esben;

    2016-01-01

    variants such as, for example, small distances in trees [Alstrup et al., SODA, 2003]. We improve the known upper and lower bounds of exact distance labeling by showing that 1/4 log2(n) bits are needed and that 1/2 log2(n) bits are sufficient. We also give (1 + ε)-stretch labeling schemes using Theta...

  20. Nutrition Marketing on Food Labels

    Science.gov (United States)

    Colby, Sarah E.; Johnson, LuAnn; Scheett, Angela; Hoverson, Bonita

    2010-01-01

    Objective: This research sought to determine how often nutrition marketing is used on labels of foods that are high in saturated fat, sodium, and/or sugar. Design and Setting: All items packaged with food labels (N = 56,900) in all 6 grocery stores in Grand Forks, ND were surveyed. Main Outcome Measure(s): Marketing strategy, nutrient label…

  1. A better carbon footprint label

    DEFF Research Database (Denmark)

    Thøgersen, John; Nielsen, Kristian S.

    2016-01-01

    Based on insights from behavioral economics, it is suggested to extend carbon footprint labeling with information about relative performance, using the well-known “traffic light” color scheme to communicate relative performance. To test this proposition, the impact of a carbon footprint label...... on Danish consumers’ choice of ground coffee was tested in a 3 price levels x 3 levels of carbon emission x 3 certifying organizations x 2 organic labeling conditions discrete choice experiment. Participants were randomly assigned to two slightly different variants of the experiment: In one condition......, participants saw the original Carbon Trust label and in the other condition they saw the same label, but with traffic light colors added to communicate the product’s relative performance in terms of carbon footprint. All included attributes were found to have a significant impact on consumer choices...

  2. Automated characterization of blood vessels as arteries and veins in retinal images.

    Science.gov (United States)

    Mirsharif, Qazaleh; Tajeripour, Farshad; Pourreza, Hamidreza

    2013-01-01

    In recent years researchers have found that alternations in arterial or venular tree of the retinal vasculature are associated with several public health problems such as diabetic retinopathy which is also the leading cause of blindness in the world. A prerequisite for automated assessment of subtle changes in arteries and veins, is to accurately separate those vessels from each other. This is a difficult task due to high similarity between arteries and veins in addition to variation of color and non-uniform illumination inter and intra retinal images. In this paper a novel structural and automated method is presented for artery/vein classification of blood vessels in retinal images. The proposed method consists of three main steps. In the first step, several image enhancement techniques are employed to improve the images. Then a specific feature extraction process is applied to separate major arteries from veins. Indeed, vessels are divided to smaller segments and feature extraction and vessel classification are applied to each small vessel segment instead of each vessel point. Finally, a post processing step is added to improve the results obtained from the previous step using structural characteristics of the retinal vascular network. In the last stage, vessel features at intersection and bifurcation points are processed for detection of arterial and venular sub trees. Ultimately vessel labels are revised by publishing the dominant label through each identified connected tree of arteries or veins. Evaluation of the proposed approach against two different datasets of retinal images including DRIVE database demonstrates the good performance and robustness of the method. The proposed method may be used for determination of arteriolar to venular diameter ratio in retinal images. Also the proposed method potentially allows for further investigation of labels of thinner arteries and veins which might be found by tracing them back to the major vessels.

  3. Sildenafil in pediatric pulmonary arterial hypertension.

    Science.gov (United States)

    Dhariwal, A K; Bavdekar, S B

    2015-01-01

    Pulmonary arterial hypertension (PAH) is a life-threatening disease of varied etiologies. Although PAH has no curative treatment, a greater understanding of pathophysiology, technological advances resulting in early diagnosis, and the availability of several newer drugs have improved the outlook for patients with PAH. Sildenafil is one of the therapeutic agents used extensively in the treatment of PAH in children, as an off-label drug. In 2012, the United States Food and Drug Administration (USFDA) issued a warning regarding the of use high-dose sildenafil in children with PAH. This has led to a peculiar situation where there is a paucity of approved therapies for the management of PAH in children and the use of the most extensively used drug being discouraged by the regulator. This article provides a review of the use of sildenafil in the treatment of PAH in children.

  4. Radionuclide evaluation of renal artery dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Born, M.L.; Gerlock, A.J. Jr.; Goncharenko, V.; Hollifield, J.W.; MacDonell, R.C. Jr.

    1981-01-01

    Radionuclide studies were used in three patients to evaluate renal perfusion and function within 24 hours following transluminal dilatation. In one patient, technetium-99 m pertechnetate showed good renal perfusion one and 12 hours after a post-dilatation arteriogram had shown a renal artery intimal defect. Improved clearance of iodine-131 ortho-iodohippurate from the blood demonstrated an increase in renal function 18 hours following dilatation of a stenosis at a renal allograft anastomosis in the second patient, while technetium-99 m-labeled DTPA showed an improved total glomerular filtration rate 24 hours after dilatation of a saphenous vein bypass graft in the third patient. It was concluded that renal radionuclide studies are of benefit in evaluating patients in the immediate post-dilatation period.

  5. Spin Hall and Spin Nernst effect from first principles

    Science.gov (United States)

    Mertig, Ingrid

    2013-03-01

    Spintronics without magnetic materials is an interesting alternative to the existing spintronics applications. The spin Hall effect creates spin currents in nonmagnetic materials and avoids the problem of spin injection. Future applications of the spin Hall effect require two properties of the materials, a large spin Hall angle and a long spin diffusion length. Ab intio calculations based on density functional theory are a powerful tool to design the desired materials and to get insight into the underlying microscopic processes. We investigated the spin Hall effect in dilute alloys, in particular the intrinsic effect based on the Berry curvature as well as side-jump and the skew-scattering contributions. The results demonstrate that a large extrinsic spin Hall effect is determined by the differences between host and impurity concerning the spin-orbit interaction. It can be caused by light p scatterers as C and N in Au. A comparable large effect is observed for heavy p scatterers as Bi in Cu. An alternative way is to deposit impurities in the adatom position. Furthermore, we predict a spin current perpendicular to a temperature gradient. The phenomenon is called spin Nernst effect. The predicted spin currents can be comparably large as in the case of the spin Hall effect.

  6. Fredkin Spin Chain

    CERN Document Server

    Salberger, Olof

    2016-01-01

    We introduce a new model of interacting spin 1/2. It describes interaction of three nearest neighbors. The Hamiltonian can be expressed in terms of Fredkin gates. The Fredkin gate (also known as the CSWAP gate) is a computational circuit suitable for reversible computing. Our construction generalizes the work of Ramis Movassagh and Peter Shor. Our model can be solved by means of Catalan combinatorics in the form of random walks on the upper half of a square lattice [Dyck walks]. Each Dyck path can be mapped to a wave function of the spins. The ground state is an equally weighted superposition of Dyck walks [instead of Motzkin walks]. We can also express it as a matrix product state. We further construct the model of interacting spins 3/2 and greater half-integer spins. The models with higher spins require coloring of Dyck walks. We construct SU(k) symmetric model [here k is the number of colors]. The leading term of the entanglement entropy is then proportional to the square root of the length of the lattice ...

  7. 21 CFR 201.71 - Magnesium labeling.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Magnesium labeling. 201.71 Section 201.71 Food and... LABELING Labeling Requirements for Over-the-Counter Drugs § 201.71 Magnesium labeling. (a) The labeling of over-the-counter (OTC) drug products intended for oral ingestion shall contain the magnesium...

  8. 16 CFR 460.12 - Labels.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Labels. 460.12 Section 460.12 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES LABELING AND ADVERTISING OF HOME INSULATION § 460.12 Labels. If you are a manufacturer, you must label all packages of your insulation. The labels...

  9. 21 CFR 610.60 - Container label.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Container label. 610.60 Section 610.60 Food and... GENERAL BIOLOGICAL PRODUCTS STANDARDS Labeling Standards § 610.60 Container label. (a) Full label. The following items shall appear on the label affixed to each container of a product capable of bearing a...

  10. Synthesis of aromatic (13)C/(2)H-α-ketoacid precursors to be used in selective phenylalanine and tyrosine protein labelling.

    Science.gov (United States)

    Lichtenecker, R J

    2014-10-14

    Recent progress in protein NMR spectroscopy revealed aromatic residues to be valuable information sources for performing structure and motion analysis of high molecular weight proteins. However, the applied NMR experiments require tailored isotope labelling patterns in order to regulate spin-relaxation pathways and optimize magnetization transfer. We introduced a methodology to use α-ketoacids as metabolic amino acid precursors in cell-based overexpression of phenylalanine and/or tyrosine labelled proteins in a recent publication, which we have now developed further by providing synthetic routes to access the corresponding side-chain labelled precursors. The target compounds allow for selective introduction of (13)C-(1)H spin systems in a highly deuterated chemical environment and feature alternating (12)C-(13)C-(12)C ring-patterns. The resulting isotope distribution is especially suited to render straightforward (13)C spin relaxation experiments possible, which provide insight into the dynamic properties of the corresponding labelled proteins.

  11. Synthesis Of Labeled Metabolites

    Science.gov (United States)

    Martinez, Rodolfo A.; Silks, III, Louis A.; Unkefer, Clifford J.; Atcher, Robert

    2004-03-23

    The present invention is directed to labeled compounds, for example, isotopically enriched mustard gas metabolites including: [1,1',2,2'-.sup.13 C.sub.4 ]ethane, 1,1'-sulfonylbis[2-(methylthio); [1,1',2,2'-.sup.13 C.sub.4 ]ethane, 1-[[2-(methylsulfinyl)ethyl]sulfonyl]-2-(methylthio); [1,1',2,2'-.sup.13 C.sub.4 ]ethane, 1,1'-sulfonylbis[2-(methylsulfinyl)]; and, 2,2'-sulfinylbis([1,2-.sup.13 C.sub.2 ]ethanol of the general formula ##STR1## where Q.sup.1 is selected from the group consisting of sulfide (--S--), sulfone (--S(O)--), sulfoxide (--S(O.sub.2)--) and oxide (--O--), at least one C* is .sup.13 C, X is selected from the group consisting of hydrogen and deuterium, and Z is selected from the group consisting of hydroxide (--OH), and --Q.sup.2 --R where Q.sup.2 is selected from the group consisting of sulfide (--S--), sulfone(--S(O)--), sulfoxide (--S(O.sub.2)--) and oxide (--O--), and R is selected from the group consisting of hydrogen, a C.sub.1 to C.sub.4 lower alkyl, and amino acid moieties, with the proviso that when Z is a hydroxide and Q.sup.1 is a sulfide, then at least one X is deuterium.

  12. Labeled Cocaine Analogs

    Science.gov (United States)

    Goodman, Mark M.; Shi, Bing Zhi; Keil, Robert N.

    1999-01-26

    Novel compounds having the structure: ##STR1## where X in .beta. configuration is phenyl, naphthyl; 2,3 or 4-iodophenyl; 2,3 or 4-(trimethylsilyl)phenyl; 3,4,5 or 6-iodonaphthyl; 3,4,5 or 6-(trimethylsilyl)naphthyl; 2,3 or 4-(trialkylstannyl)phenyl; or 3,4,5 or 6-(trialkylstannyl)naphthyl Y in .beta. configuration is Y.sub.1 or Y.sub.2, where Y.sub.1 is 2-fluoroethoxy, 3-fluoropropoxy, 4-fluorobutoxy, 2-fluorocyclopropoxy, 2 or 3-fluorocyclobutoxy, R,S 1'-fluoroisopropoxy, R 1'-fluoroisopropoxy, S 1'-fluoroisopropoxy, 1',3'-difluoroisopropoxy, R,S 1'-fluoroisobutoxy, R 1'-fluoroisobutoxy, S 1'-fluoroisobutoxy, R,S 4'-fluoroisobutoxy, R 4'-fluoroisobutoxy, S 4'-fluoroisobutoxy, or 1',1'-di(fluoromethyl)isobutoxy, and Y.sub.2 is 2-methanesulfonyloxy ethoxy, 3-methanesulfonyloxy propoxy, 4-methanesulfonyloxy butoxy, 2-methanesulfonyloxy cyclopropoxy, 2 or 3-methanesulfonyloxy cyclobutoxy, 1'methanesulfonyloxy isopropoxy, 1'-fluoro, 3'-methanesulfonyloxy isopropoxy, 1'-methanesulfonyloxy, 3'-fluoro isopropoxy, 1'-methanesulfonyloxy isobutoxy, or 4'-methanesulfonyloxy isobutoxy bind dopamine transporter protein and can be labeled with .sup.18 F or .sup.123 I for imaging.

  13. Spin-Orbit Twisted Spin Waves: Group Velocity Control

    Science.gov (United States)

    Perez, F.; Baboux, F.; Ullrich, C. A.; D'Amico, I.; Vignale, G.; Karczewski, G.; Wojtowicz, T.

    2016-09-01

    We present a theoretical and experimental study of the interplay between spin-orbit coupling (SOC), Coulomb interaction, and motion of conduction electrons in a magnetized two-dimensional electron gas. Via a transformation of the many-body Hamiltonian we introduce the concept of spin-orbit twisted spin waves, whose energy dispersions and damping rates are obtained by a simple wave-vector shift of the spin waves without SOC. These theoretical predictions are validated by Raman scattering measurements. With optical gating of the density, we vary the strength of the SOC to alter the group velocity of the spin wave. The findings presented here differ from that of spin systems subject to the Dzyaloshinskii-Moriya interaction. Our results pave the way for novel applications in spin-wave routing devices and for the realization of lenses for spin waves.

  14. Quantum spin transistor with a Heisenberg spin chain

    Science.gov (United States)

    Marchukov, O. V.; Volosniev, A. G.; Valiente, M.; Petrosyan, D.; Zinner, N. T.

    2016-10-01

    Spin chains are paradigmatic systems for the studies of quantum phases and phase transitions, and for quantum information applications, including quantum computation and short-distance quantum communication. Here we propose and analyse a scheme for conditional state transfer in a Heisenberg XXZ spin chain which realizes a quantum spin transistor. In our scheme, the absence or presence of a control spin excitation in the central gate part of the spin chain results in either perfect transfer of an arbitrary state of a target spin between the weakly coupled input and output ports, or its complete blockade at the input port. We also discuss a possible proof-of-concept realization of the corresponding spin chain with a one-dimensional ensemble of cold atoms with strong contact interactions. Our scheme is generally applicable to various implementations of tunable spin chains, and it paves the way for the realization of integrated quantum logic elements.

  15. Semiclassical spin transport in spin-orbit-coupled bands.

    Science.gov (United States)

    Culcer, Dimitrie; Sinova, Jairo; Sinitsyn, N A; Jungwirth, T; MacDonald, A H; Niu, Q

    2004-07-23

    Motivated by recent interest in novel spintronics effects, we develop a semiclassical theory of spin transport that is valid for spin-orbit coupled bands. Aside from the obvious convective term in which the average spin is transported at the wave packet group velocity, the spin current has additional contributions from the wave packet's spin and torque dipole moments. Electric field corrections to the group velocity and carrier spin contribute to the convective term. Summing all terms we obtain an expression for the intrinsic spin-Hall conductivity of a hole-doped semiconductor, which agrees with the Kubo formula prediction for the same quantity. We discuss the calculation of spin accumulation, which illustrates the importance of the torque dipole near the boundary of the system.

  16. Spin filter and spin valve in ferromagnetic graphene

    Science.gov (United States)

    Song, Yu; Dai, Gang

    2015-06-01

    We propose and demonstrate that a EuO-induced and top-gated graphene ferromagnetic junction can be simultaneously operated as a spin filter and a spin valve. We attribute such a remarkable result to a coexistence of a half-metal band and a common energy gap for opposite spins in ferromagnetic graphene. We show that both the spin filter and the spin valve can be effectively controlled by a back gate voltage, and they survive for practical metal contacts and finite temperature. Specifically, larger single spin currents and on-state currents can be reached with contacts with work functions similar to graphene, and the spin filter can operate at higher temperature than the spin valve.

  17. Spin rectification induced by spin Hall magnetoresistance at room temperature

    Science.gov (United States)

    Wang, P.; Jiang, S. W.; Luan, Z. Z.; Zhou, L. F.; Ding, H. F.; Zhou, Y.; Tao, X. D.; Wu, D.

    2016-09-01

    We have experimentally and theoretically investigated the dc voltage generation in the heterostructure of Pt and yttrium iron garnet under the ferromagnetic resonance. Besides a symmetric Lorenz line shape dc voltage, an antisymmetric Lorenz line shape dc voltage is observed in field scan, which can solely originate from the spin rectification effect due to the spin Hall magnetoresistance. The angular dependence of the dc voltage is theoretically analyzed by taking into account both the spin pumping and the spin rectification effects. We find that the experimental results are in excellent agreement with the theoretical model, further identifying the spin Hall magnetoresistance origin of the spin rectification effect. Moreover, the spin pumping and the spin rectification effects are quantitatively separated by their different angular dependence at particular experimental geometry.

  18. Quantum spin transistor with a Heisenberg spin chain

    Science.gov (United States)

    Marchukov, O. V.; Volosniev, A. G.; Valiente, M.; Petrosyan, D.; Zinner, N. T.

    2016-01-01

    Spin chains are paradigmatic systems for the studies of quantum phases and phase transitions, and for quantum information applications, including quantum computation and short-distance quantum communication. Here we propose and analyse a scheme for conditional state transfer in a Heisenberg XXZ spin chain which realizes a quantum spin transistor. In our scheme, the absence or presence of a control spin excitation in the central gate part of the spin chain results in either perfect transfer of an arbitrary state of a target spin between the weakly coupled input and output ports, or its complete blockade at the input port. We also discuss a possible proof-of-concept realization of the corresponding spin chain with a one-dimensional ensemble of cold atoms with strong contact interactions. Our scheme is generally applicable to various implementations of tunable spin chains, and it paves the way for the realization of integrated quantum logic elements. PMID:27721438

  19. Spinning fluids reactor

    Science.gov (United States)

    Miller, Jan D; Hupka, Jan; Aranowski, Robert

    2012-11-20

    A spinning fluids reactor, includes a reactor body (24) having a circular cross-section and a fluid contactor screen (26) within the reactor body (24). The fluid contactor screen (26) having a plurality of apertures and a circular cross-section concentric with the reactor body (24) for a length thus forming an inner volume (28) bound by the fluid contactor screen (26) and an outer volume (30) bound by the reactor body (24) and the fluid contactor screen (26). A primary inlet (20) can be operatively connected to the reactor body (24) and can be configured to produce flow-through first spinning flow of a first fluid within the inner volume (28). A secondary inlet (22) can similarly be operatively connected to the reactor body (24) and can be configured to produce a second flow of a second fluid within the outer volume (30) which is optionally spinning.

  20. Higher-spin correlators

    CERN Document Server

    Alday, Luis F

    2013-01-01

    We analyze the properly normalized three-point correlator of two protected scalar operators and one higher spin twist-two operator in N=4 super Yang-Mills, in the limit of large spin j. The relevant structure constant can be extracted from the OPE of the four-point correlator of protected scalar operators. We show that crossing symmetry of the four point correlator plus a judicious guess for the perturbative structure of the three-point correlator, allow to make a prediction for the structure constant at all loops in perturbation theory, up to terms that remain finite as the spin becomes large. Furthermore, the expression for the structure constant allows to propose an expression for the all loops four-point correlator G(u,v), in the limit u,v -> 0. Our predictions are in perfect agreement with the large j expansion of results available in the literature.

  1. SPIN-selling

    CERN Document Server

    Rackham, Neil

    1995-01-01

    True or false? In selling high-value products or services: "closing" increases your chance of success; it is essential to describe the benefits of your product or service to the customer; objection handling is an important skill; and open questions are more effective than closed questions. All false, says Neil Rackham. He and his team studied more than 35,000 sales calls made by 10,000 sales people in 23 countries over 12 years. Their findings revealed that many of the methods developed for selling low-value goods just don't work for major sales. Rackham went on to introduce his SPIN-selling method, where SPIN describes the whole selling process - Situation questions, Problem questions, Implication questions, Need-payoff questions. SPIN-selling provides you with a set of simple and practical techniques which have been tried in many of today's leading companies with dramatic improvements to their sales performance.

  2. Spin Waves in Terbium

    DEFF Research Database (Denmark)

    Jensen, J.; Houmann, Jens Christian Gylden

    1975-01-01

    The selection rules for the linear couplings between magnons and phonons propagating in the c direction of a simple basal-plane hcp ferromagnet are determined by general symmetry considerations. The acoustic-optical magnon-phonon interactions observed in the heavy-rare-earth metals have been...... explained by Liu as originating from the mixing of the spin states of the conduction electrons due to the spin-orbit coupling. We find that this coupling mechanism introduces interactions which violate the selection rules for a simple ferromagnet. The interactions between the magnons and phonons propagating...... in the c direction of Tb have been studied experimentally by means of inelastic neutron scattering. The magnons are coupled to both the acoustic- and optical-transverse phonons. By studying the behavior of the acoustic-optical coupling, we conclude that it is a spin-mixed-induced coupling as proposed...

  3. Paramagnetic Spin Seebeck Effect

    Science.gov (United States)

    Wu, Stephen M.; Pearson, John E.; Bhattacharya, Anand

    2015-05-01

    We report the observation of the longitudinal spin Seebeck effect in paramagnetic insulators. By using a microscale on-chip local heater, we generate a large thermal gradient confined to the chip surface without a large increase in the total sample temperature. Using this technique at low temperatures (<20 K ), we resolve the paramagnetic spin Seebeck effect in the insulating paramagnets Gd3Ga5O12 (gadolinium gallium garnet) and DyScO3 (DSO), using either W or Pt as the spin detector layer. By taking advantage of the strong magnetocrystalline anisotropy of DSO, we eliminate contributions from the Nernst effect in W or Pt, which produces a phenomenologically similar signal.

  4. Perspectives on spin glasses

    CERN Document Server

    Contucci, Pierluigi

    2013-01-01

    Presenting and developing the theory of spin glasses as a prototype for complex systems, this book is a rigorous and up-to-date introduction to their properties. The book combines a mathematical description with a physical insight of spin glass models. Topics covered include the physical origins of those models and their treatment with replica theory; mathematical properties like correlation inequalities and their use in the thermodynamic limit theory; main exact solutions of the mean field models and their probabilistic structures; and the theory of the structural properties of the spin glass phase such as stochastic stability and the overlap identities. Finally, a detailed account is given of the recent numerical simulation results and properties, including overlap equivalence, ultrametricity and decay of correlations. The book is ideal for mathematical physicists and probabilists working in disordered systems.

  5. Caliber-Persistent Artery

    Directory of Open Access Journals (Sweden)

    Sabrina Araújo Pinho Costa

    2015-01-01

    Full Text Available Caliber-persistent artery (CPLA of the lip is a common vascular anomaly in which a main arterial branch extends to the surface of the mucous tissue with no reduction in its diameter. It usually manifests as pulsatile papule, is easily misdiagnosed, and is observed more frequently among older people, suggesting that its development may involve a degenerative process associated with aging; CPLA is also characterized by the loss of tone of the adjacent supporting connective tissue. Although the diagnosis is clinical, high-resolution Doppler ultrasound is a useful noninvasive tool for evaluating the lesion. This report describes the case of a 58-year-old male patient who complained of a lesion of the lower lip with bleeding and recurrent ulceration. The patient was successfully treated in our hospital after a diagnosis of CPLA and is currently undergoing a clinical outpatient follow-up with no complaints.

  6. Zero-bias spin separation

    Science.gov (United States)

    Ganichev, Sergey D.; Bel'Kov, Vasily V.; Tarasenko, Sergey A.; Danilov, Sergey N.; Giglberger, Stephan; Hoffmann, Christoph; Ivchenko, Eougenious L.; Weiss, Dieter; Wegscheider, Werner; Gerl, Christian; Schuh, Dieter; Stahl, Joachim; de Boeck, Jo; Borghs, Gustaaf; Prettl, Wilhelm

    2006-09-01

    The generation, manipulation and detection of spin-polarized electrons in low-dimensional semiconductors are at the heart of spintronics. Pure spin currents, that is, fluxes of magnetization without charge current, are quite attractive in this respect. A paradigmatic example is the spin Hall effect, where an electrical current drives a transverse spin current and causes a non-equilibrium spin accumulation observed near the sample boundary. Here we provide evidence for an another effect causing spin currents which is fundamentally different from the spin Hall effect. In contrast to the spin Hall effect, it does not require an electric current to flow: without bias the spin separation is achieved by spin-dependent scattering of electrons in media with suitable symmetry. We show, by free-carrier absorption of terahertz (THz) radiation, that spin currents flow in a wide range of temperatures. Moreover, the experimental results provide evidence that simple electron gas heating by any means is already sufficient to yield spin separation due to spin-dependent energy-relaxation processes.

  7. Renal Artery Stent Outcomes

    Science.gov (United States)

    Murphy, Timothy P.; Cooper, Christopher J.; Matsumoto, Alan H.; Cutlip, Donald E.; Pencina, Karol M.; Jamerson, Kenneth; Tuttle, Katherine R.; Shapiro, Joseph I.; D’Agostino, Ralph; Massaro, Joseph; Henrich, William; Dworkin, Lance D.

    2016-01-01

    BACKGROUND Multiple randomized clinical trials comparing renal artery stent placement plus medical therapy with medical therapy alone have not shown any benefit of stent placement. However, debate continues whether patients with extreme pressure gradients, stenosis severity, or baseline blood pressure benefit from stent revascularization. OBJECTIVES The study sought to test the hypothesis that pressure gradients, stenosis severity, and/or baseline blood pressure affects outcomes after renal artery stent placement. METHODS Using data from 947 patients with a history of hypertension or chronic kidney disease from the largest randomized trial of renal artery stent placement, the CORAL (Cardiovascular Outcomes in Renal Atherosclerotic Lesions) study, we performed exploratory analyses to determine if subsets of patients experienced better outcomes after stent placement than the overall cohort. We examined baseline stenosis severity, systolic blood pressure, and translesion pressure gradient (peak systolic and mean) and performed interaction tests and Cox proportional hazards analyses for the occurrence of the primary endpoint through all follow-up, to examine the effect of these variables on outcomes by treatment group. RESULTS There were no statistically significant differences in outcomes based on the examined variables nor were there any consistent nonsignificant trends. CONCLUSIONS Based on data from the CORAL randomized trial, there is no evidence of a significant treatment effect of the renal artery stent procedure compared with medical therapy alone based on stenosis severity, level of systolic blood pressure elevation, or according to the magnitude of the transstenotic pressure gradient. (Benefits of Medical Therapy Plus Stenting for Renal Atherosclerotic Lesions [CORAL]; NCT00081731) PMID:26653621

  8. Spin echo in synchrotrons

    Science.gov (United States)

    Chao, Alexander W.; Courant, Ernest D.

    2007-01-01

    As a polarized beam is accelerated through a depolarization resonance, its polarization is reduced by a well-defined calculable reduction factor. When the beam subsequently crosses a second resonance, the final beam polarization is considered to be reduced by the product of the two reduction factors corresponding to the two crossings, each calculated independently of the other. This is a good approximation when the spread of spin precession frequency Δνspin of the beam (particularly due to its energy spread) is sufficiently large that the spin precession phases of individual particles smear out completely during the time τ between the two crossings. This approximate picture, however, ignores two spin dynamics effects: an interference-overlap effect and a spin echo effect. This paper is to address these two effects. The interference-overlap effect occurs when Δνspin is too small, or when τ is too short, to complete the smearing process. In this case, the two resonance crossings overlap each other, and the final polarization exhibits constructive or destructive interference patterns depending on the exact value of τ. Typically, the beam’s energy spread is large and this interference-overlap effect does not occur. To study this effect, therefore, it is necessary to reduce the beam energy spread and to consider two resonance crossings very close to each other. The other mechanism, also due to the interplay between two resonance crossings, is spin echo. It turns out that even when the precession phases appear to be completely smeared between the two crossings, there will still be a sudden and short-lived echo signal of beam polarization at a time τ after the second crossing; the magnitude of which can be as large as 57%. This echo signal exists even when the beam has a sizable energy spread and when τ is very large, and could be a sensitive (albeit challenging) way to experimentally test the intricate spin dynamics in a synchrotron. After giving an analysis

  9. Spin Echo in Synchrotrons

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Alexander W.; /SLAC; Courant, Ernest D.; /Brookhaven

    2006-12-01

    As a polarized beam is accelerated through a depolarization resonance, its polarization is reduced by a well-defined calculable reduction factor. When the beam subsequently crosses a second resonance, the final beam polarization is considered to be reduced by the product of the two reduction factors corresponding to the two crossings, each calculated independently of the other. This is a good approximation when the spread of spin precession frequency {Delta}{nu}{sub spin} of the beam (particularly due to its energy spread) is sufficiently large that the spin precession phases of individual particles smear out completely during the time {tau} between the two crossings. This approximate picture, however, ignores two spin dynamics effects: an interference effect and a spin echo effect. This paper is to address these two effects. The interference effect occurs when {Delta}{nu}{sub spin} is too small, or when {tau} is too short, to complete the smearing process. In this case, the two resonance crossings interfere with each other, and the final polarization exhibits constructive or destructive patterns depending on the exact value of {tau}. Typically, the beam's energy spread is large and this interference effect does not occur. To study this effect, therefore, it is necessary to reduce the beam energy spread and to consider two resonance crossings very close to each other. The other mechanism, also due to the interplay between two resonance crossings, is spin echo. It turns out that even when the precession phases appear to be completely smeared between the two crossings, there will still be a sudden and short-lived echo signal of beam polarization at a time {tau} after the second crossing; the magnitude of which can be as large as 57%. This echo signal exists even when the beam has a sizable energy spread and when {tau} is very large, and could be a sensitive (albeit challenging) way to experimentally test the intricate spin dynamics in a synchrotron. After giving

  10. Spin wave confinement

    CERN Document Server

    2008-01-01

    This book presents recent scientific achievements in the investigation of magnetization dynamics in confined magnetic systems. Introduced by Bloch as plane waves of magnetization in unconfined ferromagnets, spin waves currently play an important role in the description of very small magnetic systems ranging from microelements, which form the basis of magnetic sensors, to magnetic nano-contacts. The spin wave confinement effect was experimentally discovered in the 1990s in permalloy microstripes. The diversity of systems where this effect is observed has been steadily growing since then, and

  11. Spin, gravity, and inertia.

    Science.gov (United States)

    Obukhov, Y N

    2001-01-08

    The gravitational effects in the relativistic quantum mechanics are investigated. The exact Foldy-Wouthuysen transformation is constructed for the Dirac particle coupled to the static spacetime metric. As a direct application, we analyze the nonrelativistic limit of the theory. The new term describing the specific spin (gravitational moment) interaction effect is recovered in the Hamiltonian. The comparison of the true gravitational coupling with the purely inertial case demonstrates that the spin relativistic effects do not violate the equivalence principle for the Dirac fermions.

  12. The Transverse Spin

    CERN Document Server

    Artru, X

    2002-01-01

    Contents : 1. Pre-history 2. Transversity versus helicity 3. The massless limit. "Cardan" and "see-saw" transformations 4. Transversity distribution delta q(x). The diquark spectator model 5. Soffer inequality 6. Tensor charge sum rule 7. t-channel analysis 8. Selection rules for delta q(x) measurements 9. Evolution with Q squared 10. Quark polarimetry. The sheared-jet (Collins) effect 11. Single-spin asymmetries in inclusive experiments 12. Quark distribution dependent on both spin and transverse momentum 13. First evidence of quark transversity

  13. Coherent spin mixing dynamics in thermal $^{87}$Rb spin-1 and spin-2 gases

    CERN Document Server

    He, Xiaodong; Li, Xiaoke; Wang, Fudong; Xu, Zhifang; Wang, Dajun

    2015-01-01

    We study the non-equilibrium coherent spin mixing dynamics in ferromagnetic spin-1 and antiferromagnetic spin-2 thermal gases of ultracold $^{87}$Rb atoms. Long lasting spin population oscillations with magnetic field dependent resonances are observed in both cases. Our observations are well reproduced by Boltzmann equations of the Wigner distribution function. Compared to the equation of motion of spinor Bose-Einstein condensates, the only difference here is a factor of two increase in the spin-dependent interaction, which is confirmed directly in the spin-2 case by measuring the relation between the oscillation amplitude and the sample's density.

  14. Spin current swapping and spin hall effect in disordered metals

    Science.gov (United States)

    Saidaoui, Hamed; Pauyac, Christian; Manchon, Aurelien

    2015-03-01

    The conversion of charge currents into spin currents via the spin Hall effect has attracted intense experimental and theoretical efforts lately, providing an efficient means to generate electric signals and manipulate the magnetization of single layers. More recently, it was proposed that spin-dependent scattering induced by spin-orbit coupled impurities also produces a so-called spin swapping, i.e. an exchange between the spin angular momentum and linear momentum of itinerant electrons. In this work, we investigate the nature of spin swapping and its interplay with extrinsic spin Hall effect and spin relaxation in finite size normal metals. We use two complementary methods based on non-equilibrium Green's function technique. The first method consists in rigorously deriving the drift-diffusion equation of the spin accumulation in the presence of spin-orbit coupled impurities from quantum kinetics using Wigner expansion. The second method is the real-space tight binding modeling of a finite system in the presence of spin-orbit coupled disorder.

  15. Spin Caloritronic Phenomena Driven by Spin-orbit Coupling

    NARCIS (Netherlands)

    Chen, Y.-T.

    2014-01-01

    In this thesis, we report several effects in spintronics and spin caloritronics related to relativistic spin-orbit coupling. In Chapter 2, we discuss the relativistic spin caloritronicHall effects in terms of a semiclassical theory for anomalous thermoelectric effects in ferromagnetic metals due to

  16. Algorithms for Labeling Focus Regions.

    Science.gov (United States)

    Fink, M; Haunert, Jan-Henrik; Schulz, A; Spoerhase, J; Wolff, A

    2012-12-01

    In this paper, we investigate the problem of labeling point sites in focus regions of maps or diagrams. This problem occurs, for example, when the user of a mapping service wants to see the names of restaurants or other POIs in a crowded downtown area but keep the overview over a larger area. Our approach is to place the labels at the boundary of the focus region and connect each site with its label by a linear connection, which is called a leader. In this way, we move labels from the focus region to the less valuable context region surrounding it. In order to make the leader layout well readable, we present algorithms that rule out crossings between leaders and optimize other characteristics such as total leader length and distance between labels. This yields a new variant of the boundary labeling problem, which has been studied in the literature. Other than in traditional boundary labeling, where leaders are usually schematized polylines, we focus on leaders that are either straight-line segments or Bezier curves. Further, we present algorithms that, given the sites, find a position of the focus region that optimizes the above characteristics. We also consider a variant of the problem where we have more sites than space for labels. In this situation, we assume that the sites are prioritized by the user. Alternatively, we take a new facility-location perspective which yields a clustering of the sites. We label one representative of each cluster. If the user wishes, we apply our approach to the sites within a cluster, giving details on demand.

  17. How to Read a Nutrition Facts Label

    Medline Plus

    Full Text Available ... las etiquetas de datos nutricionales (video) Most packaged foods come with a Nutrition Facts label. These labels ... Watch this video for tips on figuring out food labels so you can make healthy choices. For ...

  18. Coherence Transfer in Dipolar-Coupled Homonuclear Spin Systems in Solids Rotating at the Magic Angle

    Science.gov (United States)

    Weintraub, O.; Vega, S.; Hoelger, C.; Limbach, H. H.

    Two routes for the exploitation of the t-SEDRA pulse scheme, which induces coherence transfer in dipolar-coupled homonuclear spin systems in rotating samples, are demonstrated and discussed. This sequence is utilized to deduce intramolecular connectivities by creating an initial coherence of one spin only, applying the t-SEDRA sequence, and monitoring the signal enhancement of the coupled spin. Probing the signal amplitude variations of the two spins and comparing them to simulations can also yield molecular distances. Using 2D spectroscopy, t-SEDRA can also be utilized to establish spin correlations. In this case, the t-SEDRA sequence is applied during the mixing time of a 2D dipolar-correlation experiment. These two approaches are demonstrated by performing 15N CPMAS NMR experiments on a 15N-doubly labeled sample of 3(5)-methyl-5(3)-phenylpyrazole.

  19. Case Report: Coronary arterial spasm in single right coronary artery

    Institute of Scientific and Technical Information of China (English)

    En-zhi JIA; Qi-jun SHAN; Zhi-jian YANG; Tie-bing ZHU; Lian-sheng WANG; Ke-jiang CAO; Wen-zhu MA

    2009-01-01

    We presented a case of anomalous single-coronary artery detected incidentally during routine coronary angiography. A 32-year-old male Chinese patient presented with recurrent pre-syncope and six episodes of syncope. Coronary angiography and coronary-computed tomography (CT)-angiography performed by a dual-source computed tomography (DSCT) revealed that the patient had a single large right coronary artery. A moderately large branch originated from the proximal part of the single right coronary artery and extended to the left, passing the anterior to the pulmonary artery, and divided into the anterior descending artery branch and circumflex branch at the base of the left auricular appendage. The episodes of the syncope were suspected to be caused by coronary arterial spasm, so this patient was on a regimen of 30 mg of diltiazem every 6 h and had no recurrence of syncope during follow-up.

  20. Labelling of benzocaine with tritium

    Energy Technology Data Exchange (ETDEWEB)

    Malik, Sohail (Washington Univ., Seattle, WA (United States))

    1994-10-01

    A convenient method is described to label a local anesthetic, benzocaine, with tritium. The bromoester of para-aminobenzoic acid (PABA) was prepared from para-nitrotoluene and was reduced with tritium. The generation of isotopic hydrogen and labelling of benzocaine was achieved in one-step. A mixture of sodium borohydride (NaB[sup 3]H[sub 4]) with cobalt (II) chloride was used to generate tritium gas. 5% Pd/C was used as a catalyst. This constitutes the first report of tritium labelled benzocaine. (author).

  1. New labels for radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, Susumu; Mukai, Minoru; Kato, Hirotoshi (National Inst. of Radiological Sciences, Chiba (Japan))

    1992-12-01

    In simulating radiotherapy, the bone and trachea identified by plain X-P and the other organs, such as the esophagus and bladder, outlined by contrast medium have so far been used as labels. However, irradiation with a high therapeutic ratio is required for an intracorporeal insertion of artificial labels that are identified by X-ray fluoroscopy. For this purpose, metal clips and seed dummies are available, although they cause artifacts in CT scans. Therefore, the authors are using an acupuncture needle and lipiodol for tracing as new artificial labels, since both are identified by X-ray fluoroscopy and CT scan and create few artifacts. (J.P.N.).

  2. A New Method to Correct Partial Volume Effect in ASL (Arterial Spin Labeling) Magnetic Resonance Images%一种改善动脉自旋标记磁共振图像中部分容积效应的新算法

    Institute of Scientific and Technical Information of China (English)

    黄伟; 陈光

    2015-01-01

    ASL is a novel non⁃invasive modality in functional Magnetic Resonance Imaging ( MRI) . ASL is capable of directly reflecting the Cerebral Blood Flow (CBF) of scanned patients, and is helpful to doing two things:(1) determining whether the scanned patient suffers from the dementia disease or not; ( 2 ) if the patient does suffer from the disease, determining the severity of the disease. However, since the spectral resolution of ASL is not high and problems of signal cross⁃contamination as well as voxel heterogeneity exist in this modality, the problem of Par⁃tial Volume Effect ( PVE) is commonly seen in ASL images. Moreover, PVE can easily deteriorate ASL signals, making the measured CBF of patients inaccurate and badly influencing their disease diagnosis thereafter. In this pa⁃per, a novel method solely based on single voxel information is introduced to correct PVE in ASL. Extensive experi⁃ments are conducted to suggest that this new method is not only capable of handling existing problems of blurring and brain detail loss which are commonly generated in conventional PVE correction methods but is also helpful to improving the precision of dementia disease diagnosis, from the statistical point of view.%动脉自旋标记磁共振图像是一种新颖的无侵入式的功能性磁共振图像。这类图像可以直观测量患者大脑血流量,对揭示患者是否患有老年痴呆症及判断相应的病症程度十分有效。然而,动脉自旋标记图像本身的分辨率不高,再加上扫描过程中不可避免的信号相叉污染和像素异质性等问题,使得部分容积效应在该类图像中普遍存在。部分容积效应会造成动脉自旋标记图像中信号还原失真,进而影响患者大脑血流量测量,对其病症判断带来不利影响。在文章中,一种基于单像素点信息的新颖算法被提出,改善动脉自旋标记磁共振图像中的部分容积效应。大量的统计比较实验表明,该算法不仅能解决国际上现行的改善算法中不可避免的改善结果过度模糊、丢失大脑细节信息问题,还能对准确判断患者老年痴呆病症程度能起到积极作用。

  3. General Compact Labeling Schemes for Dynamic Trees

    OpenAIRE

    2006-01-01

    Let $F$ be a function on pairs of vertices. An {\\em $F$- labeling scheme} is composed of a {\\em marker} algorithm for labeling the vertices of a graph with short labels, coupled with a {\\em decoder} algorithm allowing one to compute $F(u,v)$ of any two vertices $u$ and $v$ directly from their labels. As applications for labeling schemes concern mainly large and dynamically changing networks, it is of interest to study {\\em distributed dynamic} labeling schemes. This paper investigates labelin...

  4. Massive cerebral arterial air embolism following arterial catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.W. [Northwestem University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Yang, B.P. [Northwestern University Feinberg School of Medicine, Department of Neurological Surgery, Chicago, IL (United States)

    2005-12-01

    Microscopic cerebral arterial air embolism (CAAE) has been described in many patients undergoing cardiac surgery as well as other invasive diagnostic and therapeutic procedures. However, massive CAAE is rare. We report a 42-year-old woman who initially presented with thalamic and basal ganglia hemorrhages. Shortly after a radial arterial catheter was inserted, the patient suffered a generalized seizure and CT demonstrated intra-arterial air in bilateral cerebral hemispheres. (orig.)

  5. Perturbation of nuclear spin polarizations in solid state NMR of nitroxide-doped samples by magic-angle spinning without microwaves.

    Science.gov (United States)

    Thurber, Kent R; Tycko, Robert

    2014-05-14

    We report solid state (13)C and (1)H nuclear magnetic resonance (NMR) experiments with magic-angle spinning (MAS) on frozen solutions containing nitroxide-based paramagnetic dopants that indicate significant perturbations of nuclear spin polarizations without microwave irradiation. At temperatures near 25 K, (1)H and cross-polarized (13)C NMR signals from (15)N,(13)C-labeled L-alanine in trinitroxide-doped glycerol/water are reduced by factors as large as six compared to signals from samples without nitroxide doping. Without MAS or at temperatures near 100 K, differences between signals with and without nitroxide doping are much smaller. We attribute most of the reduction of NMR signals under MAS near 25 K to nuclear spin depolarization through the cross-effect dynamic nuclear polarization mechanism, in which three-spin flips drive nuclear polarizations toward equilibrium with spin polarization differences between electron pairs. When T1e is sufficiently long relative to the MAS rotation period, the distribution of electron spin polarization across the nitroxide electron paramagnetic resonance lineshape can be very different from the corresponding distribution in a static sample at thermal equilibrium, leading to the observed effects. We describe three-spin and 3000-spin calculations that qualitatively reproduce the experimental observations.

  6. Arterial stiffness as a risk factor for coronary artery disease.

    Science.gov (United States)

    Liao, Josh; Farmer, John

    2014-02-01

    Hypertension is a major modifiable risk factor, and clinical trials have demonstrated that successful reduction of elevated blood pressure to target levels translates into decreased risk for the development of coronary artery disease, stroke, heart failure, and renal failure. The arterial system had previously been regarded as a passive conduit for the transportation of arterial blood to peripheral tissues. The physiologic role the arterial system was greatly expanded by the recognition of the central role of the endothelial function in a variety of physiologic processes. The role of arterial function and structure in cardiovascular physiology was expanded with the development of a variety of parameters that evaluate arterial stiffness. Markers of arterial stiffness have been correlated with cardiovascular outcomes, and have been classified as an emerging risk factor that provides prognostic information beyond standard stratification strategies involving hypertension, diabetes, obesity, dyslipidemia and smoking. Multiple epidemiologic studies have correlated markers of arterial stiffness such as pulse-wave velocity, augmentation index and pulse pressure with risk for the development of fatal and nonfatal cardiovascular events. Additionally, measurements of arterial stiffness had clarified the results of clinical trials that demonstrated differing impacts on clinical outcomes, despite similar reductions in blood pressure, as measured by brachial and sphygmomanometry.

  7. Spin, mass, and symmetry

    CERN Document Server

    Peskin, Michael E

    1994-01-01

    This is a broad-brush introduction to the theory of spin in quantum field theory, presented at the 1993 SLAC Summer Institute. It may be useful for beginning students. (text only; complete paper with figures available by anonymous ftp from preprint.slac.stanford.edu, in the directory pub/preprints/hep-ph/9405)

  8. Supramolecular spin valves

    Science.gov (United States)

    Urdampilleta, M.; Klyatskaya, S.; Cleuziou, J.-P.; Ruben, M.; Wernsdorfer, W.

    2011-07-01

    Magnetic molecules are potential building blocks for the design of spintronic devices. Moreover, molecular materials enable the combination of bottom-up processing techniques, for example with conventional top-down nanofabrication. The development of solid-state spintronic devices based on the giant magnetoresistance, tunnel magnetoresistance and spin-valve effects has revolutionized magnetic memory applications. Recently, a significant improvement of the spin-relaxation time has been observed in organic semiconductor tunnel junctions, single non-magnetic molecules coupled to magnetic electrodes have shown giant magnetoresistance and hybrid devices exploiting the quantum tunnelling properties of single-molecule magnets have been proposed. Herein, we present an original spin-valve device in which a non-magnetic molecular quantum dot, made of a single-walled carbon nanotube contacted with non-magnetic electrodes, is laterally coupled through supramolecular interactions to TbPc2 single-molecule magnets (Pc=phthalocyanine). Their localized magnetic moments lead to a magnetic field dependence of the electrical transport through the single-walled carbon nanotube, resulting in magnetoresistance ratios up to 300% at temperatures less than 1 K. We thus demonstrate the functionality of a supramolecular spin valve without magnetic leads. Our results open up prospects of new spintronic devices with quantum properties.

  9. Layered kagome spin ice

    Science.gov (United States)

    Hamp, James; Dutton, Sian; Mourigal, Martin; Mukherjee, Paromita; Paddison, Joseph; Ong, Harapan; Castelnovo, Claudio

    Spin ice materials provide a rare instance of emergent gauge symmetry and fractionalisation in three dimensions: the effective degrees of freedom of the system are emergent magnetic monopoles, and the extensively many `ice rule' ground states are those devoid of monopole excitations. Two-dimensional (kagome) analogues of spin ice have also been shown to display a similarly rich behaviour. In kagome ice however the ground-state `ice rule' condition implies the presence everywhere of magnetic charges. As temperature is lowered, an Ising transition occurs to a charge-ordered state, which can be mapped to a dimer covering of the dual honeycomb lattice. A second transition, of Kosterlitz-Thouless or three-state Potts type, occurs to a spin-ordered state at yet lower temperatures, due to small residual energy differences between charge-ordered states. Inspired by recent experimental capabilities in growing spin ice samples with selective (layered) substitution of non-magnetic ions, in this work we investigate the fate of the two ordering transitions when individual kagome layers are brought together to form a three-dimensional pyrochlore structure coupled by long range dipolar interactions. We also consider the response to substitutional disorder and applied magnetic fields.

  10. TRANSVERSITY SINGLE SPIN ASYMMETRIES.

    Energy Technology Data Exchange (ETDEWEB)

    BOER,D.

    2001-04-27

    The theoretical aspects of two leading twist transversity single spin asymmetries, one arising from the Collins effect and one from the interference fragmentation functions, are reviewed. Issues of factorization, evolution and Sudakov factors for the relevant observables are discussed. These theoretical considerations pinpoint the most realistic scenarios towards measurements of transversity.

  11. Antiferromagnetic spin-orbitronics

    KAUST Repository

    Manchon, Aurelien

    2015-05-01

    Antiferromagnets have long remained an intriguing and exotic state of matter, whose application has been restricted to enabling interfacial exchange bias in metallic and tunneling spin-valves [1]. Their role in the expanding field of applied spintronics has been mostly passive and the in-depth investigation of their basic properties mostly considered from a fundamental perspective.

  12. Polyoxometalates as spin qubits

    Science.gov (United States)

    Gaita-Ariño, A.; Aldamen, M.; Clemente-Juan, J.-M.; Coronado, E.; Lehmann, J.; Loss, D.; Stamp, P.

    2008-03-01

    Polyoxometalates (POMs) are discrete fragments of metal oxides, clusters of regular MOn polyhedra. POMs show a remarkable flexibility in composition, structure and charge state, and thus can be designed according to specific electric and magnetic needs. The two localized spins with S = 1/2 on the V atoms in [PMo12O40(VO)2]^q- can be coupled through the delocalized electrons of the central core. This system was recently used for a theoretical scheme involving two-qubit gates and readout: the electrical manipulation of the molecular redox potential changes the charge of the core and thus the effective magnetic exchange between the qubits. Polyoxometalates can encapsulate magnetic ions, protecting them by a diamagnetic shell of controlled geometry. A great potential of POMs as spin qubits is that they can be constructed using only even elements, such as O, W, Mo and/or Si. Thus, there is a high abundance of polyoxometalate molecules without any nuclear spin, which could result in unusually low decoherence rates. There is currently an effort involving highly anisotropic, high magnetic moment, lanthanide@polyoxometalate molecules acting as spin qubits.

  13. Spin Injection in Indium Arsenide

    Directory of Open Access Journals (Sweden)

    Mark eJohnson

    2015-08-01

    Full Text Available In a two dimensional electron system (2DES, coherent spin precession of a ballistic spin polarized current, controlled by the Rashba spin orbit interaction, is a remarkable phenomenon that’s been observed only recently. Datta and Das predicted this precession would manifest as an oscillation in the source-drain conductance of the channel in a spin-injected field effect transistor (Spin FET. The indium arsenide single quantum well materials system has proven to be ideal for experimental confirmation. The 2DES carriers have high mobility, low sheet resistance, and high spin orbit interaction. Techniques for electrical injection and detection of spin polarized carriers were developed over the last two decades. Adapting the proposed Spin FET to the Johnson-Silsbee nonlocal geometry was a key to the first experimental demonstration of gate voltage controlled coherent spin precession. More recently, a new technique measured the oscillation as a function of channel length. This article gives an overview of the experimental phenomenology of the spin injection technique. We then review details of the application of the technique to InAs single quantum well (SQW devices. The effective magnetic field associated with Rashba spin-orbit coupling is described, and a heuristic model of coherent spin precession is presented. The two successful empirical demonstrations of the Datta Das conductance oscillation are then described and discussed.

  14. Spin Transport in Semiconductor heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Domnita Catalina Marinescu

    2011-02-22

    The focus of the research performed under this grant has been the investigation of spin transport in magnetic semiconductor heterostructures. The interest in these systems is motivated both by their intriguing physical properties, as the physical embodiment of a spin-polarized Fermi liquid, as well as by their potential applications as spintronics devices. In our work we have analyzed several different problems that affect the spin dynamics in single and bi-layer spin-polarized two-dimensional (2D) systems. The topics of interests ranged from the fundamental aspects of the electron-electron interactions, to collective spin and charge density excitations and spin transport in the presence of the spin-orbit coupling. The common denominator of these subjects is the impact at the macroscopic scale of the spin-dependent electron-electron interaction, which plays a much more subtle role than in unpolarized electron systems. Our calculations of several measurable parameters, such as the excitation frequencies of magneto-plasma modes, the spin mass, and the spin transresistivity, propose realistic theoretical estimates of the opposite-spin many-body effects, in particular opposite-spin correlations, that can be directly connected with experimental measurements.

  15. Mechanical generation of spin current

    Directory of Open Access Journals (Sweden)

    Mamoru eMatsuo

    2015-07-01

    Full Text Available We focus the recent results on spin-current generation from mechanical motion such as rigid rotation and elastic deformations. Spin transport theory in accelerating frames is constructed by using the low energy expansion of the generally covariant Dirac equation. Related issues on spin-manipulation by mechanical rotation are also discussed.

  16. Spin transport in graphene nanostructures

    NARCIS (Netherlands)

    Guimaraes, M. H. D.; van den Berg, J. J.; Vera-Marun, I. J.; Zomer, P. J.; van Wees, B. J.

    2014-01-01

    Graphene is an interesting material for spintronics, showing long spin relaxation lengths even at room temperature. For future spintronic devices it is important to understand the behavior of the spins and the limitations for spin transport in structures where the dimensions are smaller than the spi

  17. Spin-sensitive atom mirror via spin-orbit interaction

    Science.gov (United States)

    Zhou, Lu; Zheng, Ren-Fei; Zhang, Weiping

    2016-11-01

    Based on the spin-orbit coupling recently implemented in a neutral cold-atom gas, we propose a scheme to realize spin-dependent scattering of cold atoms. In particular we consider a matter wave packet of cold-atom gas impinging upon a step potential created by the optical light field, inside of which the atoms are subject to spin-orbit interaction. We show that the proposed system can act as a spin polarizer or spin-selective atom mirror for the incident atomic beam. The principle and the operating parameter regime of the system are carefully discussed.

  18. New Ideas on Labeling Schemes

    DEFF Research Database (Denmark)

    Rotbart, Noy Galil

    evaluation of fully dynamic labeling schemes. Due to a connection between adjacency labeling schemes and the graph theoretical study of induced universal graphs, we study these in depth and show novel results for bounded degree graphs and power-law graphs. We also survey and make progress on the related......With ever increasing size of graphs, many distributed graph systems emerged to store, preprocess and analyze them. While such systems ease up congestion on servers, they incur certain penalties compared to centralized data structure. First, the total storage required to store a graph...... in a distributed fashion increases. Second, attempting to answer queries on vertices of a graph stored in a distributed fashion can be significantly more complicated. In order to lay theoretical foundations to the first penalty mentioned a large body of work concentrated on labeling schemes. A labeling scheme...

  19. Off-Label Drug Use

    Science.gov (United States)

    ... it’s not legal for drug companies to market (advertise or promote) their drugs for off-label uses. ... Statistics Center Volunteer Learning Center Follow Us Twitter Facebook Instagram Cancer Information, Answers, and Hope. Available Every ...

  20. Arterial responses during migraine headache

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Olesen, J

    1990-01-01

    The superficial temporal artery has been thought to be the main focus of pain during migraine attacks, but its diameter has never been measured directly. The use of a new, high-resolution ultrasound machine to measure arterial size in 25 migraine patients with unilateral head pain showed...... that the lumen was wider on the painful than on the non-painful side during a migraine attack. The diameters of both radial arteries and the temporal artery on the non-painful side were smaller during than between attacks. The generalised vasoconstriction was not shared by the temporal artery on the affected...... side, which suggests a local vasodilatory response. The findings suggest that cephalic arteries may play a role in migraine pathogenesis....

  1. True aneurysm of brachial artery.

    Science.gov (United States)

    Hudorović, Narcis; Lovričević, Ivo; Franjić, Dario Bjorn; Brkić, Petar; Tomas, Davor

    2010-10-01

    True upper extremity peripheral artery aneurysms are a rarely encountered arterial disorder. Following computer-tomography angiographic (CT-a) imaging examination, true saccular aneurysm, originating from the left brachial artery was diagnosed in the 77-year-old female without history of trauma. The aneurysm was resected by surgical intervention, and primary repair of the brachial artery was performed by interposition of a part of great saphenous vein harvested from the left groin and creation of two end-to-end anastomoses between interposition graft and previously resected part of brachial artery. No complication was observed during the follow-up. Surgical intervention for upper extremity aneurysms should be initiated without delay. Factors combined with minimal morbidity associated with repair suggest that surgical repair should be performed routinely for true upper extremity arterial aneurysms.

  2. MRI and MR angiography of vertebral artery dissection

    Energy Technology Data Exchange (ETDEWEB)

    Mascalchi, M. [Cattedra di Radiologia, Universita di Pisa (Italy); Bianchi, M.C. [Servizio di Neuroradiologia, Ospedale S. Chiara, Pisa (Italy); Mangiafico, S. [Servizio di Neuroradiologia, Ospedale di Careggi, Firenze (Italy); Ferrito, G. [Servizio di Neuroradiologia, Ospedali Riuniti, Livorno (Italy); Puglioli, M. [Servizio di Neuroradiologia, Ospedale S. Chiara, Pisa (Italy); Marin, E. [Servizio di Radiologia, Ospedale S. M. Nuova, Firenze (Italy); Mugnai, S. [Clinica Neurologica, Universita di Firenze (Italy); Canapicchi, R. [Servizio di Neuroradiologia, Ospedale S. Chiara, Pisa (Italy); Quilici, N. [Servizio di Neuroradiologia, Ospedali Riuniti, Livorno (Italy); Inzitari, D. [Clinica Neurologica, Universita di Firenze (Italy)

    1997-05-01

    A review of 4,500 angiograms yielded 11 patients with dissection of the vertebral arteries who had MRI and (in 4 patients) MR angiography (MRA) in the acute phase of stroke. One patient with incidental discovery at arteriography of asymptomatic vertebral artery dissection and two patients with acute strokes with MRI and MRA findings consistent with vertebral artery dissection were included. Dissection occurred after neck trauma or chiropractic manipulation in 4 patients and was spontaneous in 10. Dissection involved the extracranial vertebral artery in 9 patients, the extra-intracranial junction in 1, and the intracranial artery in 4. MRI demonstrated infarcts in the brain stem, cerebellum, thalamus or temporo-occipital regions in 7 patients with extra- or extra-intracranial dissections and a solitary lateral medullary infarct in 4 patients (3 with intracranial and 1 with extra-intracranial dissection). In 2 patients no brain abnormality related to vertebral artery dissection was found and in one MRI did not show subarachnoid haemorrhage revealed by CT. Intramural dissecting haematoma appeared as crescentic or rounded high signal on T1-weighted images in 10 patients examined 3-20 days after the onset of symptoms. The abnormal vessel stood out in the low signal cerebrospinal fluid in intracranial dissections, whereas it was more difficult to detect in extracranial dissections because of the intermediate-to-high signal of the normal perivascular structures and slow flow proximal and distal to the dissection. In two patients examined within 36 h of the onset, mural thickening was of intermediate signal intensity on T1-weighted images and high signal on spin-density and T2-weighted images. MRA showed abrupt stenosis in 2 patients and disappearance of flow signal at and distal to the dissection in 5. Follow-up arteriography, MRI or MRA showed findings consistent with occlusion of the dissected vessel in 6 of 8 patients. (orig.). With 7 figs., 3 tabs.

  3. Reaching the quantum limit of sensitivity in electron spin resonance

    Science.gov (United States)

    Bienfait, A.; Pla, J. J.; Kubo, Y.; Stern, M.; Zhou, X.; Lo, C. C.; Weis, C. D.; Schenkel, T.; Thewalt, M. L. W.; Vion, D.; Esteve, D.; Julsgaard, B.; Mølmer, K.; Morton, J. J. L.; Bertet, P.

    2016-03-01

    The detection and characterization of paramagnetic species by electron spin resonance (ESR) spectroscopy is widely used throughout chemistry, biology and materials science, from in vivo imaging to distance measurements in spin-labelled proteins. ESR relies on the inductive detection of microwave signals emitted by the spins into a coupled microwave resonator during their Larmor precession. However, such signals can be very small, prohibiting the application of ESR at the nanoscale (for example, at the single-cell level or on individual nanoparticles). Here, using a Josephson parametric microwave amplifier combined with high-quality-factor superconducting microresonators cooled at millikelvin temperatures, we improve the state-of-the-art sensitivity of inductive ESR detection by nearly four orders of magnitude. We demonstrate the detection of 1,700 bismuth donor spins in silicon within a single Hahn echo with unit signal-to-noise ratio, reduced to 150 spins by averaging a single Carr-Purcell-Meiboom-Gill sequence. This unprecedented sensitivity reaches the limit set by quantum fluctuations of the electromagnetic field instead of thermal or technical noise, which constitutes a novel regime for magnetic resonance. The detection volume of our resonator is ˜0.02 nl, and our approach can be readily scaled down further to improve sensitivity, providing a new versatile toolbox for ESR at the nanoscale.

  4. Fiber optic label-free biophotonic diagnostic tool for cardiovascular disease

    Science.gov (United States)

    Rius, Cristina; Ackermann, Tobias N.; Dorado, Beatriz; Muñoz-Berbel, Xavier; Andrés, Vicente; Llobera, Andreu

    2015-06-01

    A label-free compact method for performing photonic characterization of "healthy" versus "diseased" arteries has been developed. It permits the detection of atherosclerotic lesion in living mouse arteries. Using this prototype, we observed that the spectral response (photonic fingerprint, PIN) obtained from aortas of wild-type mice differs from the response of ApoE-KO mice fed with high-fat diet (an atheroprone mouse model). Benchmark of the results against gold standard was performed by staining the aortas with Oil-Red-O to visualize atherosclerotic plaques.

  5. Inertial effect on spin-orbit coupling and spin transport

    Science.gov (United States)

    Basu, B.; Chowdhury, Debashree

    2013-08-01

    We theoretically study the renormalization of inertial effects on the spin dependent transport of conduction electrons in a semiconductor by taking into account the interband mixing on the basis of k→ṡp→ perturbation theory. In our analysis, for the generation of spin current we have used the extended Drude model where the spin-orbit coupling plays an important role. We predict enhancement of the spin current resulting from the renormalized spin-orbit coupling effective in our model in cubic and non-cubic crystals. Attention has been paid to clarify the importance of gauge fields in the spin transport of this inertial system. A theoretical proposition of a perfect spin filter has been done through the Aharonov-Casher like phase corresponding to this inertial system. For a time dependent acceleration, effect of k→ ṡp→ perturbation on the spin current and spin polarization has also been addressed. Furthermore, achievement of a tunable source of polarized spin current through the non uniformity of the inertial spin-orbit coupling strength has also been discussed.

  6. Thermal creation of a spin current by Seebeck spin tunneling

    Science.gov (United States)

    Jansen, R.; Le Breton, J. C.; Deac, A. M.; Saito, H.; Yuasa, S.

    2013-09-01

    The thermoelectric analog of spin-polarized tunneling, namely Seebeck spin tunneling, is a recently discovered phenomenon that arises from the spin-dependent Seebeck coefficient of a magnetic tunnel contact. In a tunnel junction with one ferromagnetic electrode and one non-magnetic electrode, a temperature difference between the two electrodes creates a spin current across the contact. Here, the basic principle and the observation of Seebeck spin tunneling are described. It is shown how it can be used to create a spin accumulation in silicon driven by a heat flow across a magnetic tunnel contact, without a charge tunnel current. The sign of the spin current depends on the direction of the heat flow, whereas its magnitude is anisotropic, i.e., dependent on the absolute orientation of the magnetization of the ferromagnet. The connection between Seebeck spin tunneling and the tunnel magneto-Seebeck effect, observed in metal magnetic tunnel junctions, is also clarified. Seebeck spin tunneling may be used to convert waste heat into useful thermal spin currents that aid or replace electrical spin current, and thereby improve the energy efficiency of spintronic devices and technologies.

  7. Spin anisotropy and slow dynamics in spin glasses.

    Science.gov (United States)

    Bert, F; Dupuis, V; Vincent, E; Hammann, J; Bouchaud, J-P

    2004-04-23

    We report on an extensive study of the influence of spin anisotropy on spin glass aging dynamics. New temperature cycle experiments allow us to compare quantitatively the memory effect in four Heisenberg spin glasses with various degrees of random anisotropy and one Ising spin glass. The sharpness of the memory effect appears to decrease continuously with the spin anisotropy. Besides, the spin glass coherence length is determined by magnetic field change experiments for the first time in the Ising sample. For three representative samples, from Heisenberg to Ising spin glasses, we can consistently account for both sets of experiments (temperature cycle and magnetic field change) using a single expression for the growth of the coherence length with time.

  8. Spin-transfer torque induced spin waves in antiferromagnetic insulators

    Science.gov (United States)

    Daniels, Matthew; Guo, Wei; Stocks, G. Malcolm; Xiao, Di; Xiao, Jiang

    2015-03-01

    We explore the possibility of exciting spin waves in insulating antiferromagnetic films by injecting spin current at the surface. We analyze both magnetically compensated and uncompensated interfaces. We find that the spin current induced spin-transfer torque can excite spin waves in insulating antiferromagnetic materials and that the chirality of the excited spin wave is determined by the polarization of the injected spin current. Furthermore, the presence of magnetic surface anisotropy can greatly increase the accessibility of these excitations. Supported by NSF EFRI-1433496 (M.W.D), U.S. DOE Office of Basic Energy Sciences, Materials Sciences and Engineering (D.X. & G.M.S.), Major State Basic Research Project of China and National Natural Science Foundation of China (W.G. and J.X.).

  9. Spin-optical metamaterial route to spin-controlled photonics.

    Science.gov (United States)

    Shitrit, Nir; Yulevich, Igor; Maguid, Elhanan; Ozeri, Dror; Veksler, Dekel; Kleiner, Vladimir; Hasman, Erez

    2013-05-10

    Spin optics provides a route to control light, whereby the photon helicity (spin angular momentum) degeneracy is removed due to a geometric gradient onto a metasurface. The alliance of spin optics and metamaterials offers the dispersion engineering of a structured matter in a polarization helicity-dependent manner. We show that polarization-controlled optical modes of metamaterials arise where the spatial inversion symmetry is violated. The emerged spin-split dispersion of spontaneous emission originates from the spin-orbit interaction of light, generating a selection rule based on symmetry restrictions in a spin-optical metamaterial. The inversion asymmetric metasurface is obtained via anisotropic optical antenna patterns. This type of metamaterial provides a route for spin-controlled nanophotonic applications based on the design of the metasurface symmetry properties.

  10. Spin-Currents and Spin-Pumping Forces for Spintronics

    Directory of Open Access Journals (Sweden)

    Henri-Jean Drouhin

    2011-01-01

    Full Text Available A general definition of the Spintronics concept of spin-pumping is proposed as generalized forces conjugated to the spin degrees of freedom in the framework of the theory of mesoscopic non-equilibrium thermodynamics. It is shown that at least three different kinds of spin-pumping forces and associated spin-currents can be defined in the most simple spintronics system: the Ferromagnetic/Non-Ferromagnetic metal interface. Furthermore, the generalized force associated with the ferromagnetic collective variable is also introduced on an equal footing to describe the coexistence of the spin of the conduction electrons (paramagnetic spins attached to s-band electrons and the ferromagnetic-order parameter. The dynamical coupling between these two kinds of magnetic degrees of freedom is presented and interpreted in terms of spin-transfer effects.

  11. Age, hypertension and arterial function.

    Science.gov (United States)

    McEniery, Carmel M; Wilkinson, Ian B; Avolio, Albert P

    2007-07-01

    1. Ageing exerts a marked effect on the cardiovascular system and, in particular, the large arteries. Using a variety of techniques to assess arterial stiffness, many cross-sectional studies have demonstrated a significant relationship between age and aortic stiffness, although the age-related changes observed in peripheral arteries appear to be less marked. 2. The relationship between arterial stiffness and hypertension is more complex. The distending, or mean arterial, pressure is an important confounder of measurements of arterial stiffness and, therefore, must be taken into consideration when assessing arterial stiffness in hypertensive subjects or investigating the effect of antihypertensive agents. Current methods for correcting for differences in distending pressure involve pharmacological manipulation, statistical correction or mathematical manipulation of stiffness indices. 3. Many studies have provided evidence that both peripheral (muscular) and central (elastic) arteries are stiffer in subjects with mixed (systolic/diastolic) hypertension compared with normotensive subjects. However, it is unclear to what extent differences in mean arterial pressure explain the observed differences in hypertensive subjects. In contrast, isolated systolic hypertension is associated with increased aortic, but not peripheral artery, stiffness, although the underlying mechanisms are somewhat unclear. 4. Traditional antihypertensive agents appear to reduce arterial stiffness, but mostly via an indirect effect of lowering mean pressure. Therefore, therapies that target the large arteries to reduce stiffness directly are urgently required. Agents such as nitric oxide donors and phosphodiesterase inhibitors may be useful in reducing stiffness via functional mechanisms. In addition, inhibitors or breakers of advanced glycation end-product cross-links between proteins, such as collagen and elastin, hold substantial promise.

  12. The right hepatic artery syndrome

    Institute of Scientific and Technical Information of China (English)

    Kazumi Miyashita; Katsuya Shiraki; Takeshi Ito; Hiroki Taoka; Takeshi Nakano

    2005-01-01

    Various benign and malignant conditions could cause biliary obstruction. Compression of extrahepatic bile duct (EBD) by right hepatic artery was reported as a right hepatic artery syndrome but all cases were compressed EBD from stomach side. Our case compressed from dorsum was not yet reported, so it was thought to be a very rare case. We present here the first case of bile duct obstruction due to the compression of EBD from dorsum by right hepatic artery.

  13. Spin-disordered superfluid state for spin-1 bosons with fractional spin and statistics

    OpenAIRE

    2002-01-01

    We study a strongly correlated spin-1 Bose gas in 2D space by using the projective construction. A spin-disordered superfluid state is constructed and proposed as a candidate competing with the conventional polar condensate when interaction is antiferromagnetic. This novel state has a non-trivial topological order whose low energy excitations carry fractional spin, charge, and statistics. The spin excitations become gapless only at the edge and are described by level-1 SU(2) Kac-Moody algebra...

  14. Countercurrent aortography via radial artery

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Hyung Kuk; Lee, Young Chun; Lee, Seung Chul; Jeon, Seok Chol; Joo, Kyung Bin; Lee, Seung Ro; Kim, Soon Yong [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1987-06-15

    Countercurrent aortography via radial artery was performed for detection of aortic arch anomalies in 4 infants with congenital heart disease. Author's cases of aortic arch anomalies were 3 cases of PDA, 1 case of coarctation of aorta, and 1 case of occlusion of anastomosis site on subclavian artery B-T shunt. And aberrant origin of the right SCA, interrupted aortic arch, hypoplastic aorta, anomalous origin of the right pulmonary artery from the ascending aorta can be demonstrated by this method. Countercurrent aortography affords an safe and simple method for detection of aortic arch anomalies without retrograde arterial catheterization, especially in small infants or premature babies.

  15. Arterial Abnormalities Leading to Tinnitus.

    Science.gov (United States)

    Miller, Timothy R; Serulle, Yafell; Gandhi, Dheeraj

    2016-05-01

    Tinnitus is a common symptom that usually originates in the middle ear. Vascular causes of pulsatile tinnitus are categorized by the location of the source of the noise within the cerebral-cervical vasculature: arterial, arteriovenous, and venous. Arterial stenosis secondary to atherosclerotic disease or dissection, arterial anatomic variants at the skull base, and vascular skull base tumors are some of the more common causes of arterial and arteriovenous pulsatile tinnitus. Noninvasive imaging is indicated to evaluate for possible causes of pulsatile tinnitus, and should be followed by catheter angiography if there is a strong clinical suspicion for a dural arteriovenous fistula.

  16. Pulmonary arterial hypertension in pregnancy.

    Science.gov (United States)

    Običan, Sarah G; Cleary, Kirsten L

    2014-08-01

    Pulmonary hypertension is a medical condition characterized by elevated pulmonary arterial pressure and secondary right heart failure. Pulmonary arterial hypertension is a subset of pulmonary hypertension, which is characterized by an underlying disorder of the pulmonary arterial vasculature. Pulmonary hypertension can also occur secondarily to structural cardiac disease, autoimmune disorders, and toxic exposures. Although pregnancies affected by pulmonary hypertension and pulmonary arterial hypertension are rare, the pathophysiology exacerbated by pregnancy confers both high maternal and fetal mortality and morbidity. In light of new treatment modalities and the use of a multidisciplinary approach to care, maternal outcomes may be improving.

  17. Electrical spin injection and detection of spin precession in room temperature bulk GaN lateral spin valves

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, Aniruddha; Baten, Md Zunaid; Bhattacharya, Pallab, E-mail: pkb@umich.edu [Center for Photonic and Multiscale Nanomaterials, Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2016-01-25

    We report the measurement of diffusive electronic spin transport characteristics in an epitaxial wurtzite GaN lateral spin valve at room temperature. Hanle spin precession and non-local spin accumulation measurements have been performed with the spin valves fabricated with FeCo/MgO spin contacts. Electron spin relaxation length and spin-flip lifetime of 176 nm and 37 ps, respectively, are derived from analysis of results obtained from four-terminal Hanle spin precession measurements at 300 K. The role of dislocations and defects in bulk GaN has also been examined in the context of electronic spin relaxation dynamics.

  18. Electrical spin injection and detection of spin precession in room temperature bulk GaN lateral spin valves

    Science.gov (United States)

    Bhattacharya, Aniruddha; Baten, Md Zunaid; Bhattacharya, Pallab

    2016-01-01

    We report the measurement of diffusive electronic spin transport characteristics in an epitaxial wurtzite GaN lateral spin valve at room temperature. Hanle spin precession and non-local spin accumulation measurements have been performed with the spin valves fabricated with FeCo/MgO spin contacts. Electron spin relaxation length and spin-flip lifetime of 176 nm and 37 ps, respectively, are derived from analysis of results obtained from four-terminal Hanle spin precession measurements at 300 K. The role of dislocations and defects in bulk GaN has also been examined in the context of electronic spin relaxation dynamics.

  19. Spin injection and spin accumulation in all-metal mesoscopic spin valves

    NARCIS (Netherlands)

    Jedema, FJ; Nijboer, MS; Filip, AT; van Wees, BJ

    2003-01-01

    We study the electrical injection and detection of spin accumulation in lateral ferromagnetic-metal-nonmagnetic-metal-ferromagnetic-metal (F/N/F) spin valve devices with transparent interfaces. Different ferromagnetic metals, Permalloy (Py), cobalt (Co), and nickel (Ni), are used as electrical spin

  20. Spin Structures in Magnetic Nanoparticles

    DEFF Research Database (Denmark)

    Mørup, Steen; Brok, Erik; Frandsen, Cathrine

    2013-01-01

    canting and hence a reduced magnetization. Moreover, relaxation between almost degenerate canted spin states can lead to anomalous temperature dependences of the magnetization at low temperatures. In ensembles of nanoparticles, interparticle exchange interactions can also result in spin reorientation......Spin structures in nanoparticles of ferrimagnetic materials may deviate locally in a nontrivial way from ideal collinear spin structures. For instance, magnetic frustration due to the reduced numbers of magnetic neighbors at the particle surface or around defects in the interior can lead to spin...

  1. Thermodynamic equivalence of spin systems

    Energy Technology Data Exchange (ETDEWEB)

    Beltman, J.M. (Katholieke Universiteit Nijmegen (Netherlands))

    1975-01-01

    The thermodynamic equilibrium properties of systems composed of classical spin /sup 1///sub 2/ particles (Ising spins) are studied. Given an interaction pattern between the Ising spins the main problem is to calculate the equilibrium state(s) of the system. The point put forward here is the existence of many thermodynamical equivalent spin coordinate systems. As a consequence of this phenomenon the interaction pattern of a system may be very intricate when described with respect to one spin coordinate system whereas it may become simple with respect to another one and vice versa. A systematic investigation of this phenomenon is made. (FR)

  2. [Measurement of arterial pressure].

    Science.gov (United States)

    Rorive, G

    1998-03-01

    The casual determination of blood pressure remains the basis of the diagnosis of arterial hypertension and the criteria for usefulness of drug therapy. The reference values usually in use concern determinations by the doctor in very well defined conditions, rest, size of the bladder, etc.... The poor reproductibility of the determinations made by the doctor in casual conditions has produced a large interest for new approaches: autodetermination by the patient at home, and ambulatory blood pressure determinations using automatic devices. These new approaches have their own reference values, specific indications and limitations.

  3. Quark spin-orbit correlations

    CERN Document Server

    Lorcé, Cédric

    2014-01-01

    The proton spin puzzle issue focused the attention on the parton spin and orbital angular momentum contributions to the proton spin. However, a complete characterization of the proton spin structure requires also the knowledge of the parton spin-orbit correlation. We showed that this quantity can be expressed in terms of moments of measurable parton distributions. Using the available phenomenological information about the valence quarks, we concluded that this correlation is negative, meaning that the valence quark spin and kinetic orbital angular momentum are, in average, opposite. The quark spin-orbit correlation can also be expressed more intuitively in terms of relativistic phase-space distributions, which can be seen as the mother distributions of the standard generalized and transverse-momentum dependent parton distributions. We present here for the first time some examples of the general multipole decomposition of these phase-space distributions.

  4. Efficient spin transport through polyaniline

    Science.gov (United States)

    Mendes, J. B. S.; Alves Santos, O.; Gomes, J. P.; Assis, H. S.; Felix, J. F.; Rodríguez-Suárez, R. L.; Rezende, S. M.; Azevedo, A.

    2017-01-01

    By using the spin pumping process, we show that it is possible to transport a pure spin current across layers of conducting polyaniline (PANI) with several hundred nanometers sandwiched between a film of the ferrimagnetic insulator yttrium iron garnet (YIG) and a thin layer of platinum. The spin current generated by microwave-driven ferromagnetic resonance of the YIG film, injected through the YIG/PANI interface, crosses the whole PANI layer and then is injected into the Pt layer. By means of the inverse spin Hall effect in the Pt, the spin current is converted into charge current and electrically detected as a dc voltage. We measured a spin diffusion length in PANI of 590 ± 40 nm, which is very large compared with normal metals, demonstrating that PANI can be used as an efficient spin current conductor and poor charge current conductor, opening the path towards spintronics applications based in this very attractive material.

  5. Reference values for local arterial stiffness. Part B : femoral artery

    NARCIS (Netherlands)

    Bossuyt, Jelle; Engelen, Lian; Ferreira, Isabel; Stehouwer, Coen D; Boutouyrie, Pierre; Laurent, Stéphane; Segers, Patrick; Reesink, Koen; Van Bortel, Luc M

    2015-01-01

    OBJECTIVE: Carotid-femoral pulse wave velocity (PWV) is considered the gold standard measure of arterial stiffness, representing mainly aortic stiffness. As compared with the elastic carotid and aorta, the more muscular femoral artery may be differently associated with cardiovascular risk factors (C

  6. Dual anterior descending coronary artery associated with coronary artery disease

    Directory of Open Access Journals (Sweden)

    Siqueira Luciane da L. V.

    2003-01-01

    Full Text Available The patient is a male with risk factors for coronary artery disease, who was referred for cardiac catheterization after acute myocardial infarction in the inferior wall. The patient underwent transluminal coronary angioplasty in the right coronary artery with successful stent implantation.

  7. Association between internal carotid artery dissection and arterial tortuosity

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Piga, Mario [Azienda Ospedaliero Universitaria (A.O.U.), Department of Radiology, Monserrato, Cagliari (Italy); Argiolas, Giovanni Maria; Siotto, Paolo [Azienda Ospedaliero Brotzu (A.O.B.), Department of Radiology, di Cagliari (Italy); Sumer, Suna; Wintermark, Max [Neuroradiology Division, Neuroradiology, UVA Department of Radiology, Charlottesville, VA (United States); Raz, Eytan [New York University School of Medicine, Department of Radiology, New York, NY (United States); Sapienza University of Rome, Department of Neurology and Psychiatry, Rome (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria (A.O.U.), Department of Vascular Surgery, di Cagliari (Italy)

    2014-10-18

    Carotid artery dissection is an important cause of ischemic stroke in all age groups, particularly in young patients. The purpose of this work was to assess whether there is an association between the presence of an internal carotid artery dissection (ICAD) and the arterial tortuosity. This study considered 124 patients (72 males and 52 females; median age 57 years) with CT/MR diagnosis of ICAD of the internal carotid artery were considered in this multi-centric retrospective study. The arterial tortuosity was evaluated and, when present, was categorized as elongation, kinking, or coiling. For each patient, both the right and left sides were considered for a total number of 248 arteries in order to have the same number of cases and controls. Fisher's exact test was applied to test the association between elongation, kinking, coiling, dissection, and the side affected by CAD. Fisher's exact test showed a statistically significant association between the ICAD and kinking (p = 0.0089) and coiling (p = 0.0251) whereas no statistically significant difference was found with arterial vessel elongation (p = 0.444). ICAD was more often seen on the left side compared to the right (p = 0.0001). These results were confirmed using both carotid arteries of the same patient as dependent parameter with p = 0.0012, 0.0129, and 0.3323 for kinking, coiling, and elongation, respectively. The presence of kinking and coiling is associated with ICAD. (orig.)

  8. Determination of the spin diffusion length in germanium by spin optical orientation and electrical spin injection

    Science.gov (United States)

    Rinaldi, C.; Bertoli, S.; Asa, M.; Baldrati, L.; Manzoni, C.; Marangoni, M.; Cerullo, G.; Bianchi, M.; Sordan, R.; Bertacco, R.; Cantoni, M.

    2016-10-01

    The measurement of the spin diffusion length and/or lifetime in semiconductors is a key issue for the realisation of spintronic devices, exploiting the spin degree of freedom of carriers for storing and manipulating information. In this paper, we address such parameters in germanium (0 0 1) at room temperature (RT) by three different measurement methods. Exploiting optical spin orientation in the semiconductor and spin filtering across an insulating MgO barrier, the dependence of the resistivity on the spin of photo-excited carriers in Fe/MgO/Ge spin photodiodes (spin-PDs) was electrically detected. A spin diffusion length of 0.9  ±  0.2 µm was obtained by fitting the photon energy dependence of the spin signal by a mathematical model. Electrical techniques, comprising non-local four-terminal and Hanle measurements performed on CoFeB/MgO/Ge lateral devices, led to spin diffusion lengths of 1.3  ±  0.2 µm and 1.3  ±  0.08 µm, respectively. Despite minor differences due to experimental details, the order of magnitude of the spin diffusion length is the same for the three techniques. Although standard electrical methods are the most employed in semiconductor spintronics for spin diffusion length measurements, here we demonstrate optical spin orientation as a viable alternative for the determination of the spin diffusion length in semiconductors allowing for optical spin orientation.

  9. Spin Funneling for Enhanced Spin Injection into Ferromagnets

    Science.gov (United States)

    Sayed, Shehrin; Diep, Vinh Q.; Camsari, Kerem Yunus; Datta, Supriyo

    2016-07-01

    It is well-established that high spin-orbit coupling (SOC) materials convert a charge current density into a spin current density which can be used to switch a magnet efficiently and there is increasing interest in identifying materials with large spin Hall angle for lower switching current. Using experimentally benchmarked models, we show that composite structures can be designed using existing spin Hall materials such that the effective spin Hall angle is larger by an order of magnitude. The basic idea is to funnel spins from a large area of spin Hall material into a small area of ferromagnet using a normal metal with large spin diffusion length and low resistivity like Cu or Al. We show that this approach is increasingly effective as magnets get smaller. We avoid unwanted charge current shunting by the low resistive NM layer utilizing the newly discovered phenomenon of pure spin conduction in ferromagnetic insulators via magnon diffusion. We provide a spin circuit model for magnon diffusion in FMI that is benchmarked against recent experiments and theory.

  10. Generating Functionals for Spin Foam Amplitudes

    CERN Document Server

    Hnybida, Jeff

    2014-01-01

    We construct a generating functional for the exact evalutation of a coherent representation of spin network amplitudes. This generating functional is defined for arbitrary graphs and depends only on a pair of spinors for each edge. The generating functional is a meromorphic polynomial in the spinor invariants which is determined by the cycle structure of the graph. The expansion of the spin network generating function is given in terms of a newly recognized basis of SU(2) intertwiners consisting of the monomials of the holomorphic spinor invariants. This basis is labelled by the degrees of the monomials and is thus discrete. It is also overcomplete, but contains the precise amount of data to specify points in the classical space of closed polyhedra, and is in this sense coherent. We call this new basis the discrete-coherent basis. We focus our study on the 4-valent basis, which is the first non-trivial dimension, and is also the case of interest for Quantum Gravity. We find simple relations between the new ba...

  11. How to Read a Nutrition Facts Label

    Medline Plus

    Full Text Available ... to 2-Year-Old How to Read a Nutrition Facts Label (Video) KidsHealth > For Parents > How to Read a Nutrition Facts Label (Video) Print A A A en ... nutricionales (video) Most packaged foods come with a Nutrition Facts label. These labels have a lot of ...

  12. 21 CFR 606.121 - Container label.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Container label. 606.121 Section 606.121 Food and... Container label. (a) The container label requirements are designed to facilitate the use of a uniform container label for blood and blood components (except Source Plasma) by all blood establishments. (b)...

  13. Genetics Home Reference: pulmonary arterial hypertension

    Science.gov (United States)

    ... Home Health Conditions pulmonary arterial hypertension pulmonary arterial hypertension Enable Javascript to view the expand/collapse boxes. ... PDF Open All Close All Description Pulmonary arterial hypertension is a progressive disorder characterized by abnormally high ...

  14. Accurate labeling of the light-actinide O4,5 ionization edges

    Energy Technology Data Exchange (ETDEWEB)

    Moore, K; der Laan, G v

    2006-08-23

    In this short article the accurate labeling of the O4,5 edges of the light actinides is addressed. The O4 and O5 edges are both contained in what is termed the ''giant resonance'' and the smaller ''pre-peak'' that is observed is a consequence of first-order perturbation by the 5d spin-orbit interaction. Thus, the small prepeak in the actinide 5d {yields} 5f transition should not be labeled the O5 peak, but rather the {Delta}S=1 peak.

  15. Higher Spins in Hyperspace

    CERN Document Server

    Florakis, Ioannis; Tsulaia, Mirian

    2014-01-01

    We consider the Sp(2n) invariant formulation of higher spin fields on flat and curved backgrounds of constant curvature.In this formulation an infinite number of higher spin fields are packed into single scalar and spinor master fields (hyperfields) propagating on extended spaces, to be called hyperspaces, parametrized by tensorial coordinates.We show that the free field equations on flat and AdS-like hyperspaces are related to each other by a generalized conformal transformation of the scalar and spinor master fields. We compute the four--point functions on a flat hyperspace for both scalar and spinor master fields, thus extending the two-- and three--point function results of arXiv:hep-th/0312244. Then using the generalized conformal transformation we derive two--, three-- and four--point functions on AdS--like hyperspace from the corresponding correlators on the flat hyperspace.

  16. Ground State Spin Logic

    CERN Document Server

    Whitfield, J D; Biamonte, J D

    2012-01-01

    Designing and optimizing cost functions and energy landscapes is a problem encountered in many fields of science and engineering. These landscapes and cost functions can be embedded and annealed in experimentally controllable spin Hamiltonians. Using an approach based on group theory and symmetries, we examine the embedding of Boolean logic gates into the ground state subspace of such spin systems. We describe parameterized families of diagonal Hamiltonians and symmetry operations which preserve the ground state subspace encoding the truth tables of Boolean formulas. The ground state embeddings of adder circuits are used to illustrate how gates are combined and simplified using symmetry. Our work is relevant for experimental demonstrations of ground state embeddings found in both classical optimization as well as adiabatic quantum optimization.

  17. Spin Physics at COMPASS

    CERN Document Server

    Friedrich, Jan Michael

    2006-01-01

    Results for the spin structure of the nucleon from the COMPASS data taking periods 2002 to 2004 are presented. The quark contribution to the nucleon spin, following from a QCD fit to the new data, turns out to be significantly larger than it was derived from the previous world data. The new data favour, on the other side, a comparatively small gluon polarisation in the range $x_{g} \\approx$ 0.1. In the data taken with the deuteron target polarised transversely, the related asymmetries are found to be small on the level of accuracy reached so far, indicating a cancellation of the proton and neutron contributions. This is in agreement, for both the Collins and the Sivers asymmetry, with recent theoretical calculations. Also, a step towards the understanding of angular momentum contributions with COMPASS is taken by the evaluation of asymmetries in exclusive vector meson production.

  18. Large Spin Perturbation Theory

    CERN Document Server

    Alday, Luis F

    2016-01-01

    We consider conformal field theories around points of large twist degeneracy. Examples of this are theories with weakly broken higher spin symmetry and perturbations around generalised free fields. At the degenerate point we introduce twist conformal blocks. These are eigenfunctions of certain quartic operators and encode the contribution, to a given four-point correlator, of the whole tower of intermediate operators with a given twist. As we perturb around the degenerate point, the twist degeneracy is lifted. In many situations this breaking is controlled by inverse powers of the spin. In such cases the twist conformal blocks can be decomposed into a sequence of functions which we systematically construct. Decomposing the four-point correlator in this basis turns crossing symmetry into an algebraic problem. Our method can be applied to a wide spectrum of conformal field theories in any number of dimensions and at any order in the breaking parameter. As an example, we compute the spectrum of various theories ...

  19. An Optimal Labeling Scheme for Ancestry Queries

    OpenAIRE

    2009-01-01

    An ancestry labeling scheme assigns labels (bit strings) to the nodes of rooted trees such that ancestry queries between any two nodes in a tree can be answered merely by looking at their corresponding labels. The quality of an ancestry labeling scheme is measured by its label size, that is the maximal number of bits in a label of a tree node. In addition to its theoretical appeal, the design of efficient ancestry labeling schemes is motivated by applications in web search engines. For this p...

  20. A brief history of cell labelling

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M. [Royal Sussex Country Hospital, Brighton (United Kingdom)

    2005-12-15

    The term cell labelling is usually used in the context of labelled leukocytes for imaging inflammation and labelled platelets for imaging thrombosis. Erythrocyte labelling for in vitro measurements of red cell life span, in vivo measurements of splenic red cell pooling, radionuclide ventriculography and imaging sites of bleeding has developed rather separately and has a different history. Labelled platelets and leukocytes were originally developed for cell kinetic studies. Since the current-day applications of labelled platelets and leukocytes depend on a clear understanding of cell kinetics, these classical studies are important and relevant to the history of cell labelling.