WorldWideScience

Sample records for arterial pressure levels

  1. The effects of upper body exercise across different levels of blood flow restriction on arterial occlusion pressure and perceptual responses.

    Science.gov (United States)

    Mattocks, Kevin T; Jessee, Matthew B; Counts, Brittany R; Buckner, Samuel L; Grant Mouser, J; Dankel, Scott J; Laurentino, Gilberto C; Loenneke, Jeremy P

    2017-03-15

    Recent studies have investigated relative pressures that are applied during blood flow restriction exercise ranging from 40%-90% of resting arterial occlusion pressure; however, no studies have investigated relative pressures below 40% arterial occlusion pressure. The purpose of this study was to characterize the cardiovascular and perceptual responses to different levels of pressures. Twenty-six resistance trained participants performed four sets of unilateral elbow flexion exercise using 30% of their 1RM in combination with blood flow restriction inflated to one of six relative applied pressures (0%, 10%, 20%, 30%, 50%, 90% arterial occlusion pressure). Arterial occlusion pressure was measured before (pre) and immediately after the last set of exercise at the radial artery. RPE and discomfort were taken prior to (pre) and following each set of exercise. Data presented as mean (95% CI) except for perceptual responses represented as the median (25th, 75th percentile). Arterial occlusion pressure increased from pre to post (pexercise (pexercise. Applying higher relative pressures results in the greatest cardiovascular response, higher perceptual ratings, and greater decrease in exercise volume compared to lower restriction pressures. Therefore, the perceptual responses from lower relative pressures may be more appealing and provide a safer and more tolerable stimulus for individuals. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Investigation Of Arterial Blood Pressure Level And Metabolic Indices In Patients With Arterial Hypertension At Pharmacotherapy With Antihypertensive Medicines Of Various Chemical Structure

    Directory of Open Access Journals (Sweden)

    G.Kh. Glybochko

    2009-12-01

    Full Text Available The research goal is to carry on the comparative analysis of medicines of various chemical structure, Telmisar-tan and Bisoprolol, and to reveal their effect on the arterial blood pressure level and the indices of various metabolic processes in patients with arterial hypertension. 60 out-patients with arterial hypertension (stage II risk III both males and females aged 33-55 have been under study taking Telmisartan and Bisoprolol for 3 months. While treating the patients the arterial blood pressure level control and biochemical investigations for determination the indices of metabolic processes have been carried out. The investigated medications have provided the decrease of systolic and diastolic arterial pressure parameters, the increase of concentration of total and ionized calcium, chlorine ions, urea and total bilirubin in blood plasma. Therapy with Telmisartan has shown more significant increase of potassium level in erythro-cytes, decrease of levels of natrium, glucose, glycolized hemoglobin and triglycerides and increased contents of alani-naminotransferase and aspartataminotransferase. The course of therapy with Bisoprolol has restored the normal level of magnesium in blood plasma, has not have any influence on carbohydrate and lipid metabolism, increased the level of alaninaminotransferase and significantly increased the contents of total and ionized calcium, urea and creatinine. 3-months therapy with Telmisartan and Bisoprolol has proved the decrease of systolic and diastolic arterial pressure in patients with arterial hypertension. The medications under study have had active and variable effects on metabolic indices

  3. Multiple level arterial occlusions of the leg. Reliability of indirect thigh pressures in the assessment of proximal arterial obstruction

    DEFF Research Database (Denmark)

    Noer, Ivan; Tønnesen, K H; Lassen, N A

    1981-01-01

    19 patients with obstructive arterial disease both proximal and distal to the inguinal ligament were studied with segmental blood pressure recordings because reconstruction of the proximal lesion was considered. The common femoral pressure was measured intraarterially as well as with a 12 cm cuff...... placed as proximally as possible on the thigh. The proximal pressures measured by the two techniques were found to correlate well. Thus, the atraumatic cuff pressure technique is validated which can be of use in evaluating multilevel occlusions and the associated run off problem involved in partial...

  4. [Measurement of arterial pressure].

    Science.gov (United States)

    Rorive, G

    1998-03-01

    The casual determination of blood pressure remains the basis of the diagnosis of arterial hypertension and the criteria for usefulness of drug therapy. The reference values usually in use concern determinations by the doctor in very well defined conditions, rest, size of the bladder, etc.... The poor reproductibility of the determinations made by the doctor in casual conditions has produced a large interest for new approaches: autodetermination by the patient at home, and ambulatory blood pressure determinations using automatic devices. These new approaches have their own reference values, specific indications and limitations.

  5. Effect of continuous positive airway pressure treatment on serum adiponectin level and mean arterial pressure in male patients with obstructive sleep apnea syndrome

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xi-long; YIN Kai-sheng; LI Chong; JIA En-zhi; LI Yan-qun; GAO Zhao-fang

    2007-01-01

    Background Recent research suggested that obstructive sleep apnea syndrome (OSAS) might be independently associated with hypoadiponectinemia, which was linked to some complications of OSAS, such as hypertension, diabetes,etc. This study was conducted to investigate the effect of continuous positive airway pressure (CPAP) treatment on changes of both serum adiponectin levels and mean arterial pressure and their possible links in male OSAS patients.Methods Twenty-three adult male patients with moderate-to-severe OSAS but without obesity, coronary heart disease and diabetes were recruited. Their blood sampleswere collected and moming mean arterial pressure (MAP) was measured before CPAP treatment and on day 3, 7, 14 of CPAP treatment respectively. The serum adiponectin concentration was tested with radioimmunoassay.Results Compared with the serum adiponectin level before CPAP treatment, no significant change was found in OSAS patients on day 3 and day 7 of CPAP treatment (P>0.05). It was not until day 14 of CPAP treatment did a significant elevation in serum adiponectin level occur (P<0.01). Meanwhile, the MAP showed no statistically significant difference among its levels before CPAP, on day 3 and day 7 of CPAP treatment (P>0.05). However, on day 14 of CPAP treatment,a significantly lower MAP than that obtained before treatment was observed (P<0.05).Conclusions CPAP treatment can gradually reverse hypoadiponectinemia and reduce MAP in OSAS patients.Hypoadiponectinemia might be involved in the pathogenesis of OSAS-mediated hypertension.

  6. Exhaled and arterial levels of endothelin-1 are increased and correlate with pulmonary systolic pressure in COPD with pulmonary hypertension

    Directory of Open Access Journals (Sweden)

    Dragonieri Silvano

    2008-09-01

    Full Text Available Abstract Background Endothelin-1 (ET-1 and Nitric Oxide (NO are crucial mediators for establishing pulmonary artery hypertension (PAH. We tested the hypothesis that their imbalance might also occur in COPD patients with PAH. Methods The aims of the study were to measure exhaled breath condensate (EBC and circulating levels of ET-1, as well as exhaled NO (FENO levels by, respectively, a specific enzyme immunoassay kit, and by chemiluminescence analysis in 3 groups of subjects: COPD with PAH (12, COPD only (36, and healthy individuals (15. In order to evaluate pulmonary-artery systolic pressure (PaPs, all COPD patients underwent Echo-Doppler assessment. Results Significantly increased exhaled and circulating levels of ET-1 were found in COPD with PAH compared to both COPD (p 1%, (r = -0.59, p = 0.043, and PaPs negatively correlated to PaO2 (r = -0.618; p = 0.032. Significantly reduced levels of FENO were found in COPD associated with PAH, compared to COPD only (22.92 ± 11.38 vs.35.07 ± 17.53 ppb; p = 0.03. Thus, we observed an imbalanced output in the breath between ET-1 and NO, as expression of pulmonary endothelium and epithelium impairment, in COPD with PAH compared to COPD only. Whether this imbalance is an early cause or result of PAH due to COPD is still unknown and deserves further investigations.

  7. Arterial Pressure Monitoring in Mice

    Science.gov (United States)

    Zhao, Xin; Ho, David; Gao, Shumin; Hong, Chull; Vatner, Dorothy E.; Vatner, Stephen F.

    2011-01-01

    The use of mice for the evaluation and study of cardiovascular pathophysiology is growing rapidly, primarily due to the relative ease for developing genetically engineered mouse models. Arterial pressure monitoring is central to the evaluation of the phenotypic changes associated with cardiovascular pathology and interventions in these transgenic and knockout models. There are four major techniques for measuring arterial pressure in the mouse: tail cuff system, implanted fluid filled catheters, Millar catheters and implanted telemetry systems. Here we provide protocols for their use and discuss the advantages and limitations for each of these techniques . PMID:21686061

  8. Does the serum uric acid level have any relation to arterial stiffness or blood pressure in adults with congenital renal agenesis and/or hypoplasia?

    Science.gov (United States)

    Yazici, Raziye; Guney, İbrahim; Altintepe, Lutfullah; Yazici, Mehmet

    2017-01-01

    The relationship between serum uric acid and arterial stiffness or blood pressure is not clear. The serum uric acid level and its association with cardiovascular risk is not well known in patients with reduced renal mass. We aimed to investigate the relation between serum uric acid levels and arterial stiffness and also blood pressure in patients with congenital renal agenesis and/or hypoplasia. In this single center, cross-sectional study, a total of 55 patients (39 (% 70.9) with unilateral small kidney and 16 (%29.1) with renal agenesis) were included. The median age was 35 (21-50) years. The study population was divided into tertiles of serum uric acid (according to 2.40-3.96, 3.97-5.10, and 5.11-9.80 mg/dl cut-off values of serum uric acid levels). Official and 24-h ambulatory non-invasive blood pressures of all patients were measured. The arterial stiffness was assessed by pulse wave velocity (PWV). PWV values were increased from first to third tertile (5.5 ± 0.6, 5.7 ± 0.8, 6.1 ± 0.7, respectively), but this gradual increase between tertiles did not reach significance. Linear regression analyses showed a positive correlation between serum uric acid levels and PWV (β = 0.40, p = 0.010), but no correlation was found between uric acid and daytime systolic blood pressure (β = 0.24, p = 0.345). In congenital renal agenesis/hypoplasia, the serum uric acid level was positively correlated with arterial stiffness, but there was no correlation with blood pressure.

  9. Correlation of invasive central arterial pressure with peripheral arterial pressure and coronary sclerosis

    Institute of Scientific and Technical Information of China (English)

    吴琪

    2013-01-01

    Objective To study the consistency among non-invasive and invasive brachial artery pressure,radial artery pressure and invasive central arterial pressure,and to explore the correlation between the severe degree of coronary artery disease and invasive central aortic pressure.

  10. Reconstruction of brachial pressure from finger arterial pressure during orthostasis

    DEFF Research Database (Denmark)

    Bogert, Lysander W J; Harms, Mark P M; Pott, Frank

    2004-01-01

    In patients with recurrent syncope, monitoring of intra-arterial pressure during orthostatic stress testing is recommended because of the potentially sudden and rapid development of hypotension. Replacing brachial arterial pressure (BAP) by the non-invasively obtained finger arterial pressure (Fi...

  11. Reconstruction of brachial pressure from finger arterial pressure during orthostasis

    DEFF Research Database (Denmark)

    Bogert, Lysander W J; Harms, Mark P M; Pott, Frank;

    2004-01-01

    In patients with recurrent syncope, monitoring of intra-arterial pressure during orthostatic stress testing is recommended because of the potentially sudden and rapid development of hypotension. Replacing brachial arterial pressure (BAP) by the non-invasively obtained finger arterial pressure (Fin...

  12. Pulse Wave Velocity as Marker of Preclinical Arterial Disease: Reference Levels in a Uruguayan Population Considering Wave Detection Algorithms, Path Lengths, Aging, and Blood Pressure

    Directory of Open Access Journals (Sweden)

    Ignacio Farro

    2012-01-01

    Full Text Available Carotid-femoral pulse wave velocity (PWV has emerged as the gold standard for non-invasive evaluation of aortic stiffness; absence of standardized methodologies of study and lack of normal and reference values have limited a wider clinical implementation. This work was carried out in a Uruguayan (South American population in order to characterize normal, reference, and threshold levels of PWV considering normal age-related changes in PWV and the prevailing blood pressure level during the study. A conservative approach was used, and we excluded symptomatic subjects; subjects with history of cardiovascular (CV disease, diabetes mellitus or renal failure; subjects with traditional CV risk factors (other than age and gender; asymptomatic subjects with atherosclerotic plaques in carotid arteries; patients taking anti-hypertensives or lipid-lowering medications. The included subjects (n=429 were categorized according to the age decade and the blood pressure levels (at study time. All subjects represented the “reference population”; the group of subjects with optimal/normal blood pressures levels at study time represented the “normal population.” Results. Normal and reference PWV levels were obtained. Differences in PWV levels and aging-associated changes were obtained. The obtained data could be used to define vascular aging and abnormal or disease-related arterial changes.

  13. A longitudinal study of arterial blood pressure in chronic haemodialysis patients with different levels of plasma renin concentration.

    Science.gov (United States)

    Kornerup, H J; Fredsted, B; Pedersen, R S

    1978-01-01

    The purpose of the study was to examine the value of regular measurements of plasma renin concentration (PRC) in selecting those chronic haemodialysis patients suitable for bilateral nephrectomy to prevent development of uncontrollable hypertension. Regular measurements of arterial blood pressure (BP) and PRC were performed during one year in 31 patients undergoing regular haemodialysis because of end-stage renal disease. Among 18 patients with PRC greater than or equal to 100 micro Goldblatt units per ml plasma (microGU/ml) systolic and/or diastolic hypertension persisted or developed in 12. In contrast, among 13 patients with PRC greater than 100microGU/ml, BP became normal in all but one, who had a slightly increased systolic BP. However, hypertension was mild and easily controlled by conventional therapy in all except one, who probably had an overlying volume-dependent hypertension. Therefore, bilateral nephrectomy was not necessary in any case. The results indicate that hypertension in the majority of chronic haemodialysis patients with high PRC can be adequately controlled without surgical intervention and that regular measurements of PRC have no practical value in forecasting the development of uncontrollable hypertension in chronic haemodialysis patients.

  14. Morphine in ventilated neonates: Its effects on arterial blood pressure

    NARCIS (Netherlands)

    S.H. Simons (Sinno); D.W.E. Roofthooft (Daniella); M. van Dijk (Monique); R.A. Lingen (Richard); H.J. Duivenvoorden (Hugo); J.N. van den Anker (John); D. Tibboel (Dick)

    2006-01-01

    markdownabstractObjective: To study the effects of continuous morphine infusion on arterial blood pressure in ventilatedneonates. Design: Blinded randomised placebo controlled trial. Setting: Level III neonatal intensive care unit in two centres. Patients: A total of 144 ventilated

  15. Pressure Change in an Arterial Constriction

    Science.gov (United States)

    Mungan, Carl E.

    2015-01-01

    Consider the following ConcepTest. A platelet is drifting with the blood flowing through a horizontal artery. As the platelet enters a constriction, does the blood pressure increase, decrease, or stay the same?

  16. Low-level lead exposure increases systolic arterial pressure and endothelium-derived vasodilator factors in rat aortas.

    Directory of Open Access Journals (Sweden)

    Jonaina Fiorim

    Full Text Available Chronic lead exposure induces hypertension and alters endothelial function. However, treatment with low lead concentrations was not yet explored. We analyzed the effects of 7 day exposure to low lead concentrations on endothelium-dependent responses. Wistar rats were treated with lead (1st dose 4 µg/100 g, subsequent dose 0.05 µg/100 g, i.m. to cover daily loss or vehicle; blood levels attained at the end of treatment were 9.98 µg/dL. Lead treatment had the following effects: increase in systolic blood pressure (SBP; reduction of contractile response to phenylephrine (1 nM-100 µM of aortic rings; unaffected relaxation induced by acetylcholine (0.1 nM-300 µM or sodium nitroprusside (0.01 nM-0.3 µM. Endothelium removal, N(G-nitro-L-arginine methyl ester (100 µM and tetraethylammonium (2 mM increased the response to phenylephrine in treated rats more than in untreated rats. Aminoguanidine (50 µM increased but losartan (10 µM and enalapril (10 µM reduced the response to phenylephrine in treated rats. Lead treatment also increased aortic Na(+/K(+-ATPase functional activity, plasma angiotensin-converting enzyme (ACE activity, protein expression of the Na(+/K(+-ATPase alpha-1 subunit, phosphorylated endothelial nitric oxide synthase (p-eNOS, and inducible nitric oxide synthase (iNOS. Our results suggest that on initial stages of lead exposure, increased SBP is caused by the increase in plasma ACE activity. This effect is accompanied by increased p-eNOS, iNOS protein expression and Na(+/K(+-ATPase functional activity. These factors might be a compensatory mechanism to the increase in SBP.

  17. Low-Level Lead Exposure Increases Systolic Arterial Pressure and Endothelium-Derived Vasodilator Factors in Rat Aortas

    Science.gov (United States)

    Fiorim, Jonaina; Ribeiro Júnior, Rogério F.; Silveira, Edna A.; Padilha, Alessandra S.; Vescovi, Marcos Vinícius A.; de Jesus, Honério C.; Stefanon, Ivanita; Salaices, Mercedes; Vassallo, Dalton V.

    2011-01-01

    Chronic lead exposure induces hypertension and alters endothelial function. However, treatment with low lead concentrations was not yet explored. We analyzed the effects of 7 day exposure to low lead concentrations on endothelium-dependent responses. Wistar rats were treated with lead (1st dose 4 µg/100 g, subsequent dose 0.05 µg/100 g, i.m. to cover daily loss) or vehicle; blood levels attained at the end of treatment were 9.98 µg/dL. Lead treatment had the following effects: increase in systolic blood pressure (SBP); reduction of contractile response to phenylephrine (1 nM–100 µM) of aortic rings; unaffected relaxation induced by acetylcholine (0.1 nM–300 µM) or sodium nitroprusside (0.01 nM–0.3 µM). Endothelium removal, NG-nitro-L-arginine methyl ester (100 µM) and tetraethylammonium (2 mM) increased the response to phenylephrine in treated rats more than in untreated rats. Aminoguanidine (50 µM) increased but losartan (10 µM) and enalapril (10 µM) reduced the response to phenylephrine in treated rats. Lead treatment also increased aortic Na+/K+-ATPase functional activity, plasma angiotensin-converting enzyme (ACE) activity, protein expression of the Na+/K+-ATPase alpha-1 subunit, phosphorylated endothelial nitric oxide synthase (p-eNOS), and inducible nitric oxide synthase (iNOS). Our results suggest that on initial stages of lead exposure, increased SBP is caused by the increase in plasma ACE activity. This effect is accompanied by increased p-eNOS, iNOS protein expression and Na+/K+-ATPase functional activity. These factors might be a compensatory mechanism to the increase in SBP. PMID:21364929

  18. Feasibility of using finger arterial pressure in neonates

    OpenAIRE

    Drouin, E.; Gournay, V; Calamel, J.; Mouzard, A.; Roze, J

    1997-01-01

    The feasibility of using a Finapres device to reproduce the beat to beat signal of arterial blood pressure in eight neonates was assessed and compared with intra-arterial measurement of arterial blood pressure in the umbilical artery, using a catheter. The two methods gave similar results. Continuous recording of arterial blood pressure in neonates using Finapres is feasible and reliable.

 Keywords: blood pressure monitoring; Finapres; umbilical artery

  19. Control of arterial pressure in aquatic sea snakes.

    Science.gov (United States)

    Lillywhite, H B; Pough, F H

    1983-01-01

    Cardiovascular responses to head-up tilt, acutely graded hemorrhage, and pharmacologic stimulation by principal autonomic drugs were studied in four species of marine snakes, principally Aipysurus laevis (family Hydrophiidae). Arterial pressure varied inversely with tilt angle and blood volume deficit in conscious snakes outside of water, indicating that physiological regulation was poor or lacking. Calculated arterial pressures at head level typically diminished to zero in A. laevis tilted to angles greater than or equal to 30 degrees. Arterial pressure (corrected for external water pressure) did not change when these snakes were tilted in seawater. Changes of arterial pressure induced by tilt, blood loss, or autonomic drugs elicited reflex adjustments in heart activity, but the magnitude of these responses was less than that observed in terrestrial species of snake. It is concluded that baroreflexes are present but comparatively ineffective in sea snakes. Snakes tolerated large losses of blood volume, and extravascular fluids were absorbed into the circulation during hemorrhage; both hemorrhage and estimated hemodilution volumes exceeded 100% of the initial blood volume in Acalyptophis peronii. Thus, in marine snakes major fluid shifts between nonvascular and vascular compartments significantly compensate hypovolemia but, because of minor autonomic adjustments, do not result in a well-regulated arterial pressure.

  20. Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study

    National Research Council Canada - National Science Library

    Jacq, Gwenaëlle; Gritti, Karine; Carré, Cécile; Fleury, Nadège; Lang, Annie; Courau-Courtois, Josette; Bedos, Jean-Pierre; Legriel, Stephane

    2015-01-01

    Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position...

  1. Arterial pressure suffices to increase liver stiffness.

    Science.gov (United States)

    Piecha, Felix; Peccerella, Teresa; Bruckner, Tom; Seitz, Helmut-Karl; Rausch, Vanessa; Mueller, Sebastian

    2016-11-01

    Noninvasive measurement of liver stiffness (LS) has been established to screen for liver fibrosis. Since LS is also elevated in response to pressure-related conditions such as liver congestion, this study was undertaken to learn more about the role of arterial pressure on LS. LS was measured by transient elastography (μFibroscan platform, Echosens, Paris, France) during single intravenous injections of catecholamines in anesthetized rats with and without thioacetamide (TAA)-induced fibrosis. The effect of vasodilating glycerol trinitrate (GTN) on LS was also studied. Pressures in the abdominal aorta and caval and portal veins were measured in real time with the PowerLab device (AD Instruments, Dunedin, New Zealand). Baseline LS values in all rats (3.8 ± 0.5 kPa, n = 25) did not significantly differ from those in humans. Epinephrine and norepinephrine drastically increased mean arterial pressure (MAP) from 82 to 173 and 156 mmHg. Concomitantly, LS almost doubled from 4 to 8 kPa, while central venous pressure remained unchanged. Likewise, portal pressure only showed a slight and delayed increase. In the TAA-induced fibrosis model, LS increased from 9.5 ± 1.0 to 25.6 ± 14.7 kPa upon epinephrine injection and could efficiently be decreased by GTN. We finally show a direct association in humans in a physiological setting of elevated cardiac output and MAP. During continuous spinning at 200 W, MAP increased from 84 ± 8 to 99 ± 11 mmHg while LS significantly increased from 4.4 ± 1.8 to 6.7 ± 2.1 kPa. In conclusion, our data show that arterial pressure suffices to increase LS. Moreover, lowering MAP efficiently decreases LS in fibrotic livers that are predominantly supplied by arterial blood. Copyright © 2016 the American Physiological Society.

  2. Morphine in ventilated neonates: Its effects on arterial blood pressure

    NARCIS (Netherlands)

    S.H. Simons (Sinno); D.W.E. Roofthooft (Daniella); M. van Dijk (Monique); R.A. Lingen (Richard); H.J. Duivenvoorden (Hugo); J.N. van den Anker (John); D. Tibboel (Dick)

    2006-01-01

    markdownabstractObjective: To study the effects of continuous morphine infusion on arterial blood pressure in ventilatedneonates. Design: Blinded randomised placebo controlled trial. Setting: Level III neonatal intensive care unit in two centres. Patients: A total of 144 ventilated neonates. I

  3. Effects of different levels of positive airway pressure on breathing pattern and heart rate variability after coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    C.B.F. Pantoni

    2011-01-01

    Full Text Available The application of continuous positive airway pressure (CPAP produces important hemodynamic alterations, which can influence breathing pattern (BP and heart rate variability (HRV. The aim of this study was to evaluate the effects of different levels of CPAP on postoperative BP and HRV after coronary artery bypass grafting (CABG surgery and the impact of CABG surgery on these variables. Eighteen patients undergoing CABG were evaluated postoperatively during spontaneous breathing (SB and application of four levels of CPAP applied in random order: sham (3 cmH2O, 5 cmH2O, 8 cmH2O, and 12 cmH2O. HRV was analyzed in time and frequency domains and by nonlinear methods and BP was analyzed in different variables (breathing frequency, inspiratory tidal volume, inspiratory and expiratory time, total breath time, fractional inspiratory time, percent rib cage inspiratory contribution to tidal volume, phase relation during inspiration, phase relation during expiration. There was significant postoperative impairment in HRV and BP after CABG surgery compared to the preoperative period and improvement of DFAα1, DFAα2 and SD2 indexes, and ventilatory variables during postoperative CPAP application, with a greater effect when 8 and 12 cmH2O were applied. A positive correlation (P < 0.05 and r = 0.64; Spearman was found between DFAα1 and inspiratory time to the delta of 12 cmH2O and SB of HRV and respiratory values. Acute application of CPAP was able to alter cardiac autonomic nervous system control and BP of patients undergoing CABG surgery and 8 and 12 cmH2O of CPAP provided the best performance of pulmonary and cardiac autonomic functions.

  4. Clinical review: Interpretation of arterial pressure wave in shock states

    OpenAIRE

    Lamia, Bouchra; Chemla, Denis; Richard, Christian; Teboul, Jean-Louis

    2005-01-01

    In critically ill patients monitored with an arterial catheter, the arterial pressure signal provides two types of information that may help the clinician to interpret haemodynamic status better: the mean values of systolic, diastolic, mean and pulse pressures; and the magnitude of the respiratory variation in arterial pressure in patients undergoing mechanical ventilation. In this review we briefly discuss the physiological mechanisms responsible for arterial pressure generation, with specia...

  5. Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure.

    Science.gov (United States)

    Zheng, Dingchang; Murray, Alan

    2009-05-29

    Arterial wall function is associated with different physiological and clinical factors. Changes in arterial pressure cause major changes in the arterial wall. This study presents a simple non-invasive method to quantify arterial volume distensibility changes with different arterial pressures. The electrocardiogram, finger and ear photoplethysmogram were recorded from 15 subjects with the right arm at five different positions (90 degrees , 45 degrees , 0 degrees , -45 degrees and -90 degrees referred to the horizontal level). Arm pulse propagation time was determined by subtracting ear pulse transit time from finger pulse transit time, and was used to obtain arterial volume distensibility. The mean arterial blood pressure with the arm at the horizontal level was acquired, and changes with position were calculated using the hydrostatic principle that blood pressure in the arm is linearly related to its vertical distance from the horizontal level. The mean arm pulse propagation times for the five different positions were 88, 72, 57, 54 and 52ms, with the corresponding mean arterial volume distensibility of 0.234%, 0.158%, 0.099%, 0.088% and 0.083% per mmHg. For all consecutive changes in arm position, arm pulse propagation time and arterial volume distensibility, were significantly different (all probability Ppressure decreased significantly between each consecutive arm position from 90 degrees to -45 degrees (all Ppressure changes from 101 to 58mmHg. In conclusion, the inverse and non-linear relationship between arterial volume distensibility and arterial pressure has been quantified using a simple arm positioning procedure, with the greatest effect at low pressures. This work is an important step in developing a simple non-invasive technique for assessing peripheral arterial volume distensibility.

  6. Porcine radial artery decellularization by high hydrostatic pressure.

    Science.gov (United States)

    Negishi, Jun; Funamoto, Seiichi; Kimura, Tsuyoshi; Nam, Kwangoo; Higami, Tetsuya; Kishida, Akio

    2015-11-01

    Many types of decellularized tissues have been studied and some have been commercially used in clinics. In this study, small-diameter vascular grafts were made using HHP to decellularize porcine radial arteries. One decellularization method, high hydrostatic pressure (HHP), has been used to prepare the decellularized porcine tissues. Low-temperature treatment was effective in preserving collagen and collagen structures in decellularized porcine carotid arteries. The collagen and elastin structures and mechanical properties of HHP-decellularized radial arteries were similar to those of untreated radial arteries. Xenogeneic transplantation (into rats) was performed using HHP-decellularized radial arteries and an untreated porcine radial artery. Two weeks after transplantation into rat carotid arteries, the HHP-decellularized radial arteries were patent and without thrombosis. In addition, the luminal surface of each decellularized artery was covered by recipient endothelial cells and the arterial medium was fully infiltrated with recipient cells.

  7. Ambulatory pulmonary arterial pressure in primary pulmonary hypertension: variability, relation to systemic arterial pressure, and plasma catecholamines.

    OpenAIRE

    Richards, A. M.; Ikram, H; Crozier, I G; Nicholls,M.G.; Jans, S.

    1990-01-01

    The variability of pulmonary arterial pressure, the relation of pulmonary pressure to systemic pressure, pulmonary pressure responses to stimuli (exercise, hypoxia, smoking, free ambulation), and plasma catecholamine responses were assessed in five patients with primary pulmonary hypertension. Ambulatory monitoring techniques provided data for the computerised analysis of continuous, beat-to-beat, direct recordings of both pulmonary and systemic arterial pressures for 8 to 10 hours. The absol...

  8. Acute effects of traditional Thai massage on cortisol levels, arterial blood pressure and stress perception in academic stress condition: A single blind randomised controlled trial.

    Science.gov (United States)

    Bennett, Surussawadi; Bennett, Michael John; Chatchawan, Uraiwon; Jenjaiwit, Patcharaporn; Pantumethakul, Rungthip; Kunhasura, Soontorn; Eungpinichpong, Wichai

    2016-04-01

    Traditional Thai massage (TTM) has been applied widely to promote relaxation. However, there is little evidence to support its efficacy on academic stress. A randomised controlled trial was performed to examine the acute effects of TTM on cortisol level, blood pressure, heart rate and stress perception in academic stress. This prospective trial included 36 physiotherapy students with a self perceived stress score of between 3 and 5. They were randomly allocated into the TTM (18 people) group or the control group (18 people). Saliva cortisol level, blood pressure, heart rate and stress perception rating were measured before and after the intervention. Both groups showed a significant reduction in cortisol level and heart rate when compared with baseline (p stress of TTM.

  9. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...

  10. Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study.

    Science.gov (United States)

    Mignini, Mariano Alejandro; Piacentini, Enrique; Dubin, Arnaldo

    2006-01-01

    Invasive arterial blood pressure monitoring is a common practice in intensive care units (ICUs). Accuracy of invasive blood pressure monitoring is crucial in evaluating the cardiocirculatory system and adjusting drug therapy for hemodynamic support. However, the best site for catheter insertion is controversial. Lack of definitive information in critically ill patients makes it difficult to establish guidelines for daily practice in intensive care. We hypothesize that peripheral and central mean arterial blood pressures are interchangeable in critically ill patients. This is a prospective, observational study carried out in a surgical-medical ICU in a teaching hospital. Fifty-five critically ill patients with clinical indication of invasive arterial pressure monitoring were included in the study. No interventions were made. Simultaneous measurements were registered in central (femoral) and peripheral (radial) arteries. Bias and precision between both measurements were calculated with Bland-Altman analysis for the whole group. Bias and precision were compared between patients receiving high doses of vasoactive drugs (norepinephrine or epinephrine >0.1 microg/kg/minute or dopamine >10 microg/kg/minute) and those receiving low doses (norepinephrine or epinephrine arterial pressure was 3 +/- 4 mmHg higher than peripheral mean arterial pressure for the whole population and there were no differences between groups (3 +/- 4 mmHg for both groups). Measurement of mean arterial blood pressure in radial or femoral arteries is clinically interchangeable. It is not mandatory to cannulate the femoral artery, even in critically ill patients receiving high doses of vasoactive drugs.

  11. Noninvasive continuous arterial blood pressure monitoring with Nexfin®.

    Science.gov (United States)

    Martina, Jerson R; Westerhof, Berend E; van Goudoever, Jeroen; de Beaumont, Edouard M F H; Truijen, Jasper; Kim, Yu-Sok; Immink, Rogier V; Jöbsis, Dorothea A; Hollmann, Markus W; Lahpor, Jaap R; de Mol, Bas A J M; van Lieshout, Johannes J

    2012-05-01

    If invasive measurement of arterial blood pressure is not warranted, finger cuff technology can provide continuous and noninvasive monitoring. Finger and radial artery pressures differ; Nexfin® (BMEYE, Amsterdam, The Netherlands) measures finger arterial pressure and uses physiologic reconstruction methodologies to obtain values comparable to invasive pressures. Intra-arterial pressure (IAP) and noninvasive Nexfin arterial pressure (NAP) were measured in cardiothoracic surgery patients, because invasive pressures are available. NAP-IAP differences were analyzed during 30 min. Tracking was quantified by within-subject precision (SD of individual NAP-IAP differences) and correlation coefficients. The ranges of pressure change were quantified by within-subject variability (SD of individual averages of NAP and IAP). Accuracy and precision were expressed as group average ± SD of the differences and considered acceptable when smaller than 5 ± 8 mmHg, the Association for the Advancement of Medical Instrumentation criteria. NAP and IAP were obtained in 50 (34-83 yr, 40 men) patients. For systolic, diastolic, mean arterial, and pulse pressure, median (25-75 percentiles) correlation coefficients were 0.96 (0.91-0.98), 0.93 (0.87-0.96), 0.96 (0.90-0.97), and 0.94 (0.85-0.98), respectively. Within-subject precisions were 4 ± 2, 3 ± 1, 3 ± 2, and 3 ± 2 mmHg, and within-subject variations 13 ± 6, 6 ± 3, 9 ± 4, and 7 ± 4 mmHg, indicating precision over a wide range of pressures. Group average ± SD of the NAP-IAP differences were -1 ± 7, 3 ± 6, 2 ± 6, and -3 ± 4 mmHg, meeting criteria. Differences were not related to mean arterial pressure or heart rate. Arterial blood pressure can be measured noninvasively and continuously using physiologic pressure reconstruction. Changes in pressure can be followed and values are comparable to invasive monitoring.

  12. Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery.

    NARCIS (Netherlands)

    Hofhuizen, C.M.; Lemson, J.; Hemelaar, A.E.A.; Settels, J.J.; Schraa, O.; Singh, S.K.; Hoeven, J.G. van der; Scheffer, G.J.

    2010-01-01

    BACKGROUND: Continuous non-invasive measurement of finger arterial pressure (FAP) is a reliable technology in adults. FAP is measured with an inflatable cuff around the finger and simultaneously converted to a reconstructed brachial artery pressure waveform (reBAP) by the Nexfin device. We assessed

  13. Noninvasive Measurement of Central Vascular Pressures With Arterial Tonometry: Clinical Revival of the Pulse Pressure Waveform?

    Science.gov (United States)

    Nelson, Matthew R.; Stepanek, Jan; Cevette, Michael; Covalciuc, Michael; Hurst, R. Todd; Tajik, A. Jamil

    2010-01-01

    The arterial pulse has historically been an essential source of information in the clinical assessment of health. With current sphygmomanometric and oscillometric devices, only the peak and trough of the peripheral arterial pulse waveform are clinically used. Several limitations exist with peripheral blood pressure. First, central aortic pressure is a better predictor of cardiovascular outcome than peripheral pressure. Second, peripherally obtained blood pressure does not accurately reflect central pressure because of pressure amplification. Lastly, antihypertensive medications have differing effects on central pressures despite similar reductions in brachial blood pressure. Applanation tonometry can overcome the limitations of peripheral pressure by determining the shape of the aortic waveform from the radial artery. Waveform analysis not only indicates central systolic and diastolic pressure but also determines the influence of pulse wave reflection on the central pressure waveform. It can serve as a useful adjunct to brachial blood pressure measurements in initiating and monitoring hypertensive treatment, in observing the hemodynamic effects of atherosclerotic risk factors, and in predicting cardiovascular outcomes and events. Radial artery applanation tonometry is a noninvasive, reproducible, and affordable technology that can be used in conjunction with peripherally obtained blood pressure to guide patient management. Keywords for the PubMed search were applanation tonometry, radial artery, central pressure, cardiovascular risk, blood pressure, and arterial pulse. Articles published from January 1, 1995, to July 1, 2009, were included in the review if they measured central pressure using radial artery applanation tonometry. PMID:20435839

  14. Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery.

    Science.gov (United States)

    Hofhuizen, C M; Lemson, J; Hemelaar, A E A; Settels, J J; Schraa, O; Singh, S K; van der Hoeven, J G; Scheffer, G J

    2010-10-01

    Continuous non-invasive measurement of finger arterial pressure (FAP) is a reliable technology in adults. FAP is measured with an inflatable cuff around the finger and simultaneously converted to a reconstructed brachial artery pressure waveform (reBAP) by the Nexfin™ device. We assessed the adequacy of a prototype device (Nexfin-paediatric), designed for a paediatric population, for detecting rapid arterial pressure changes in children during cardiac surgery. Thirteen anaesthetized children with a median age of 11 months (2 months-7 yr) undergoing congenital cardiac surgery were included in the study. reBAP and intra-arterial pressure (IAP) were recorded simultaneously during the surgical procedure. To assess the accuracy of reBAP in tracking arterial pressure changes, the four largest IAP variations within a 5 min time interval were identified from each procedure. These variations were compared offline with reBAP during a 10 s control period before and a 10 s period after an arterial pressure change had occurred. In 10 out of 13 children, a non-invasive arterial pressure recording could be obtained. Therefore, recordings from these 10 children were eligible for further analysis, resulting in 40 data points. The correlation coefficient between reBAP and IAP in tracking mean arterial pressure (MAP) changes was 0.98. reBAP followed changes in IAP with a mean bias for systolic, diastolic arterial pressure, and MAP of 0.0 mm Hg (sd 5.8), 0.1 (sd 2.8), and 0.19 (sd 2.7), respectively. The prototype device closely follows arterial pressure changes in children. However, in a considerable number of attempts, obtaining a signal was time-consuming or unsuccessful. This technique seems promising but requires further technical development.

  15. [Features of arterial blood pressure in elderly persons of different ethnic groups in Yakutsk].

    Science.gov (United States)

    Nikitin, Iu P; Tatarinova, O V; Neustroeva, V N; Shcherbakova, L V; Sidorov, A S

    2013-01-01

    The differences in arterial blood pressure in the sample of population in the age of 60 and older of different ethnic groups in Yakutsk, as well as its connection with the other cardiovascular diseases risk factors have been analyzed. It was shown that the average values of systolic and diastolic blood pressure in subsample of the Yakuts appeared to be lower than in Caucasoid gerontic persons. The average values of systolic arterial blood pressure both in the Yakuts and in the Caucasoids were detected higher than normal values in all age-dependent subgroups. The average values of diastolic blood pressure in both ethnic groups were within the limits of high normal level. From 60 to 90 years and older the decrease in systolic and diastolic arterial blood pressure was detected; it was more marked in Caucasoid gerontic persons. The average values of pulse pressure in the Yakuts and in the Caucasoids appeared to be higher than the existing standard and didn't have any differences in ethnic groups. In both ethnical subsamples, pulse pressure values increase was observed in persons of 60-89 years old and its decrease after 90. Persons with overweight, obesity, central (abdominal) obesity, dyslypoproteidemias irrespective of belonging to ethnical group were characterized as having higher levels of arterial blood pressure. Statistically significant differences in the levels of arterial blood pressure in the Yakuts and in the Caucasoids depending on hyperglycemia, smoking, the presence of burdened anamnesis, educational level, marital status was not detected.

  16. Intermittent hypoxia and diet-induced obesity: effects on oxidative status, sympathetic tone, plasma glucose and insulin levels, and arterial pressure.

    Science.gov (United States)

    Olea, Elena; Agapito, Maria Teresa; Gallego-Martin, Teresa; Rocher, Asuncion; Gomez-Niño, Angela; Obeso, Ana; Gonzalez, Constancio; Yubero, Sara

    2014-10-01

    Obstructive sleep apnea (OSA) consists of sleep-related repetitive obstructions of upper airways that generate episodes of recurrent or intermittent hypoxia (IH). OSA commonly generates cardiovascular and metabolic pathologies defining the obstructive sleep apnea syndrome (OSAS). Literature usually links OSA-associated pathologies to IH episodes that would cause an oxidative status and a carotid body-mediated sympathetic hyperactivity. Because cardiovascular and metabolic pathologies in obese patients and those with OSAS are analogous, we used models (24-wk-old Wistar rats) of IH (applied from weeks 22 to 24) and diet-induced obesity (O; animals fed a high-fat diet from weeks 12 to 24) to define the effect of each individual maneuver and their combination on the oxidative status and sympathetic tone of animals, and to quantify cardiovascular and metabolic parameters and their deviation from normality. We found that IH and O cause an oxidative status (increased lipid peroxides and diminished activities of superoxide dismutases), an inflammatory status (augmented C-reactive protein and nuclear factor kappa-B activation), and sympathetic hyperactivity (augmented plasma and renal artery catecholamine levels and synthesis rate); combined treatments worsened those alterations. IH and O augmented liver lipid content and plasma cholesterol, triglycerides, leptin, glycemia, insulin levels, and HOMA index, and caused hypertension; most of these parameters were aggravated when IH and O were combined. IH diminished ventilatory response to hypoxia, and hypercapnia and O created a restrictive ventilatory pattern; a combination of treatments led to restrictive hypoventilation. Data demonstrate that IH and O cause comparable metabolic and cardiovascular pathologies via misregulation of the redox status and sympathetic hyperactivity.

  17. [Reproducibility of arterial pressure measured in the ELSA-Brasil with 24-hour pressure monitoring].

    Science.gov (United States)

    Nascimento, Larissa Rangel; Molina, Maria del Carmen Bisi; Faria, Carolina Perim; Cunha, Roberto de Sá; Mill, José Geraldo

    2013-06-01

    To determine the reproducibility of casual arterial pressure measurement and to confirm pressure diagnosis by monitoring of participants in the ELSA-Brasil (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health). Casual blood pressure was measured with an oscilometric device. A sub-sample of participants (N = 255) from Espírito Santo state (Southeastern Brazil) was reevaluated using the same methodology following one to ten weeks and, in addition, underwent arterial blood pressure monitoring. Diagnosis of hypertension used cut off points of 140/90 mmHg for casual pressure and 130/80 mmHg for arterial blood pressure monitoring. White coat hypertension was defined as the presence of hypertension in casual blood pressure and normal arterial blood pressure monitoring, and converse findings characterized masked hypertension. Data are from 230 participants that on the two occasions were free from antihypertensive medication (N1 = 153) or under the same antihypertensive regimen (N2 = 77). Normotension was confirmed by arterial blood pressure monitoring in 120 out of 134 participants of the N1 group. In N2, blood pressure control was confirmed by arterial blood pressure monitoring in 43 of 54 participants with controlled hypertension per casual blood pressure. Overall diagnostic concordance between casual blood pressure and arterial blood pressure monitoring was 78% (kappa = 0.44). In the N1 group, six subjects (4%) presented white coat hypertension, and 23 subjects (25%) presented with masked hypertension. Diagnostic concordance between casual blood pressure and arterial blood pressure monitoring was moderate. The rigorous standardization of casual blood pressure measurement adopted in the ELSA-Brasil study was able to reduce white coat hypertension. The high frequency of masked hypertension may suggest that pressure values obtained by arterial blood pressure monitoring indicate an elevated degree of stress at work.

  18. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P pressures......, but surprisingly normal arterial blood pressure during the nighttime, and the circadian variation in blood pressure and HR is diminished, probably because of an almost unaltered cardiac output during the 24 hours. These results may reflect a major defect in the ability of optimal regulation of blood pressure...

  19. Harmonics tracking of intracranial and arterial blood pressure waves.

    Science.gov (United States)

    Shahsavari, Sima; McKelvey, Tomas

    2008-01-01

    Considering cardiorespiratory interaction and heart rate variability, a new approach is proposed to decompose intracranial pressure and arterial blood pressure to their different harmonics. The method is based on tracking the amplitudes of the harmonics by a Kalman filter based tracking algorithm. The algorithm takes benefit of combined frequency estimation technique which uses both Fast Fourier Transform and RR-interval detection. The result would be of use in intracranial pressure and arterial blood pressure waveform analysis as well as other investigations which need to estimate contribution of specific harmonic in above mentioned signals such as Pressure-Volume Compensatory Reserve assessment.

  20. Blood Pressure Is the Determinant for the Increased Risk for Intracranial Arterial Stenosis in Subjects with Elevated Glycated Hemoglobin Levels: The Kangbuk Samsung Health Study.

    Science.gov (United States)

    Oh, Hyung-Geun; Rhee, Eun-Jung

    2016-11-01

    Ischemic stroke is known to be an important vascular complication of diabetes. Intracranial arterial stenosis (ICAS) is considered as an important cause of stroke in Asians. We aimed to analyze the risk for ICAS assessed by transcranial Doppler (TCD) ultrasonography in different groups of young Korean subjects divided by glycated hemoglobin (HbA1c) levels. This study included 10,437 participants without history of cardiovascular diseases (81.3% men, mean age 43 years) from a health screening program, in whom TCD ultrasonography was used to detect greater than 50% ICAS based on criteria modified from the SONIA (Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis) trial. The subjects were divided into 3 groups according to HbA1c levels: HbA1c < 5.7%, 5.7 ≤ HbA1c < 6.5%, and HbA1c ≥ 6.5% or under medication for diabetes. Among the participants, 3.0% of the subjects had ICAS. The subjects with ICAS tended to have higher mean HbA1c level compared with those without ICAS (5.8 ± .8 versus 5.7 ± .6, P = .063). The proportion of subjects with ICAS significantly increased as the HbA1c increased from the first to the third group (2.8%, 3.0%, 4.6%, P for linear trend = .022). In logistic regression analysis with ICAS as the dependent variable, the group with HbA1c ≥ 6.5% showed significantly increased odds ratio for ICAS with subjects with HbA1c < 5.7% as the reference after adjustment for confounding variables (1.575, 95% confidence interval 1.056-2.347). However, this significance disappeared with inclusion of presence of hypertension in the model. The risk for ICAS assessed by TCD was increased in young Korean subjects with HbA1c ≥ 6.5%. However, this significance was attenuated after adjustment for presence of hypertension, suggesting the importance of hypertension in ICAS. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. Characterization and calibration of the central arterial pressure waveform obtained from vibrocardiographic signal

    Science.gov (United States)

    Casacanditella, L.; Cosoli, G.; Casaccia, S.; Rohrbaugh, J. W.; Scalise, L.; Tomasini, E. P.

    2016-06-01

    Laser Doppler Vibrometry (LDV) has been demonstrated to be a non-contact technique with high sensitivity, able to measure the skin vibrations related to cardiac activity. The obtainable mechanical signal (i.e. a velocity signal), VibroCardioGram (VCG), is able to provide significant physiological parameters, such as Heart Rate (HR). In this work, the authors aim to present a non-contact measurement method to obtain the arterial blood pressure signal from the mechanical vibrations assessed by LDV, in a central district of the arterial tree, such as carotid artery. In fact, in this way it is possible to indirectly assess Central Arterial Blood Pressure (CABP), which indicates the hemodynamic load on the heart, so that it is considered an important index predicting the cardiac risk of a subject. The measurement setup involves the use of an oscillometric cuff, to measure peripheral blood pressure at the radial artery level. Diastolic and Mean Arterial Pressure (MAP) at radial level were used to calibrate the integrated LDV signal (i.e. a displacement signal). As regard calibration, an exponential mathematical model was adopted to derive the pressure waveform from the displacement of the vessel detected by LDV. Results show an average difference of around 20% between systolic pressure measured at brachial level (i.e. peripheral pressure value) and systolic pressure derived from VCG signal measured over the carotid artery (i.e. central pressure). This is a physiological difference, consistent with the literature about the physiological increase of Systolic Blood Pressure (SBP) and Pressure Pulse (PP) at increased distances from the heart. However, this non-contact technique is affected by movement artifacts and by reflection phenomena not related to the studied vessel and so it is necessary to account of such issues in the results.

  2. DAILY BLOOD PRESSURE MONITORING AND ARTERIAL RIGIDITY DATA IN OSTEOARTHRITIS PATIENTS WITH AND WITHOUT ARTERIAL HYPERTENSION

    Directory of Open Access Journals (Sweden)

    I.A. Kharitonova

    2009-03-01

    Full Text Available We have compared the daily blood pressure monitoring data with arterial wall rigidity parameters in patients with osteoarthritis with and without arterial hypertension. In 32% of patients with osteoarthritis without arterial hypertension we have determined “non-dipper” type and in 16% of patients - “night-peaker”. In case of arterial hypertension 42,8% of patients with osteoarthritis have “night-peaker” type and 22,8% of patients have “non-dipper” type. We have found the correlation between augmentation indices and daily blood pressure parameters.

  3. Drinking and arterial blood pressure responses to ANG II in young and old rats

    Science.gov (United States)

    Beltz, Terry G.; Johnson, Alan Kim

    2010-01-01

    We investigated water drinking and arterial blood pressure responses to intravenous infusions of ANG II in young (4 mo), middle-aged adult (12 mo), and old (29 mo) male Brown Norway rats. Infusions of ANG II began with arterial blood pressure either at control levels or at reduced levels following injection of the vasodilator minoxidil. Under control conditions, mean arterial pressure (MAP) in response to ANG II rose to the same level for all groups, and middle-aged and old rats drank as much or more water in response to ANG II compared with young rats, depending on whether intakes were analyzed using absolute or body weight-adjusted values. When arterial blood pressure first was reduced with minoxidil, MAP in response to ANG II stabilized at significantly lower levels compared with control conditions for all groups. Young rats drank significantly more water under reduced pressure conditions compared with control conditions, while middle-aged and old rats did not. Urine volume in response to ANG II was lower, while water balance was higher, under conditions of reduced pressure compared with control conditions. Baroreflex control of heart rate was substantially reduced in old rats compared with young and middle-aged animals. In summary, young rats appear to be more sensitive to the inhibitory effects of increased arterial blood pressure on water drinking than are older animals. PMID:20739604

  4. A new technique for assessing arterial pressure wave forms and central pressure with tissue Doppler

    Science.gov (United States)

    Haluska, Brian A; Jeffriess, Leanne; Mottram, Phillip M; Carlier, Stephane G; Marwick, Thomas H

    2007-01-01

    Background Non-invasive assessment of arterial pressure wave forms using applanation tonometry of the radial or carotid arteries can be technically challenging and has not found wide clinical application. 2D imaging of the common carotid arteries is routinely used and we sought to determine whether arterial waveform measurements could be derived from tissue Doppler imaging (TDI) of the carotid artery. Methods We studied 91 subjects (52 men, age 52 ± 14 years) with and without cardiovascular disease. Tonometry was performed on the carotid artery simultaneously with pulsed wave Doppler of the LVOT and acquired digitally. Longitudinal 2D images of the common carotid artery with and without TDI were also acquired digitally and both TDI and tonometry were calibrated using mean and diastolic cuff pressure and analysed off line. Results Correlation between central pressure by TDI and tonometry was excellent for maximum pressure (r = 0.97, p < 0.0001). The mean differences between central pressures derived by TDI and tonometry were minimal (systolic 5.36 ± 5.5 mmHg; diastolic 1.2 ± 1.2 mmHg). Conclusion Imaging of the common carotid artery motion with tissue Doppler may permit acquisition of a waveform analogous to that from tonometry. This method may simplify estimation of central arterial pressure and calculation of total arterial compliance. PMID:17266772

  5. Acute lead exposure increases arterial pressure: role of the renin-angiotensin system.

    Directory of Open Access Journals (Sweden)

    Maylla Ronacher Simões

    Full Text Available BACKGROUND: Chronic lead exposure causes hypertension and cardiovascular disease. Our purpose was to evaluate the effects of acute exposure to lead on arterial pressure and elucidate the early mechanisms involved in the development of lead-induced hypertension. METHODOLOGY/PRINCIPAL FINDINGS: Wistar rats were treated with lead acetate (i.v. bolus dose of 320 µg/Kg, and systolic arterial pressure, diastolic arterial pressure and heart rate were measured during 120 min. An increase in arterial pressure was found, and potential roles of the renin-angiotensin system, Na(+,K(+-ATPase and the autonomic reflexes in this change in the increase of arterial pressure found were evaluated. In anesthetized rats, lead exposure: 1 produced blood lead levels of 37±1.7 µg/dL, which is below the reference blood concentration (60 µg/dL; 2 increased systolic arterial pressure (Ct: 109±3 mmHg vs Pb: 120±4 mmHg; 3 increased ACE activity (27% compared to Ct and Na(+,K(+-ATPase activity (125% compared to Ct; and 4 did not change the protein expression of the α1-subunit of Na(+,K(+-ATPase, AT(1 and AT(2. Pre-treatment with an AT(1 receptor blocker (losartan, 10 mg/Kg or an ACE inhibitor (enalapril, 5 mg/Kg blocked the lead-induced increase of arterial pressure. However, a ganglionic blockade (hexamethonium, 20 mg/Kg did not prevent lead's hypertensive effect. CONCLUSION: Acute exposure to lead below the reference blood concentration increases systolic arterial pressure by increasing angiotensin II levels due to ACE activation. These findings offer further evidence that acute exposure to lead can trigger early mechanisms of hypertension development and might be an environmental risk factor for cardiovascular disease.

  6. Femoral artery pressure measurement to predict the outcome of arterial surgery in patients with multilevel disease

    DEFF Research Database (Denmark)

    Faris, I; Tønnesen, K H; Agerskov, K;

    1982-01-01

    Direct measurement of the femoral artery pressure before operation has been used to predict the postoperative change in ankle and toe pressure in 102 limbs (83 patients) that underwent aortoiliac surgery for the treatment of atherosclerotic occlusion or stenosis affecting both the aortoiliac...... and femoral artery segments. Rest pain or gangrene was present in 74 limbs. In 26 other limbs simultaneous aortoiliac and femoral artery reconstructions were performed. The changes in both toe and ankle pressures could be confidently predicted from the preoperative data. A predicted toe pressure of lower than...... 25 mm Hg was associated with a high probability that amputation would be required. The chances of an amputation were less than 3% if a toe pressure higher than 40 mm Hg was predicted. If the predicted ankle pressure index was lower than 0.56, there was a 90% chance that intermittent claudication...

  7. Efectos crónicos de un programa de alargamiento pasivo sobre los valores de la presión arterial sanguinea y el estrés en adultos con hipertensión arterial. Chronics effects of a passive stretching program on the blood pressures and stress levels of hypertensions adults.

    Directory of Open Access Journals (Sweden)

    Bezerra da Silva, Elirez

    2007-07-01

    Full Text Available ResumenEl objetivo de este estudio fue analizar los efectos crónicos de un programa de alargamiento pasivo sobre la presión arterial sanguínea y estrés en adultos con hipertensión arterial. Participaron de este estudio, 12 personas de ambos sexos, con edad media de 52,12±5,5 años, sedentarios y con diagnóstico médico de hipertensión arterial. Las variables recolectadas para la realización de la investigación fueron la presión arterial sanguínea y el estrés de dichas personas. El tratamiento estadístico fue realizado por análisis descriptivos y análisis de inferencia. Los tests estadísticos de naturaleza comparativa fueron realizado a través de los análisis de variancia (ANOVA one-way yuxtapuesto con el test de Post hoc de Tukey, para identificar las posibles diferencias entre los datos de la presión arterial sanguínea. El test de Kruskal-Wallis fue usado para comparar las respuestas del cuestionario de estrés. Fue admitido el valor de pAbstractPurpose of this study was verifier the chronics effects of passive stretching programs on the stress and blood pressure levels of adults with arterial hypertension. 12 subjects of both gender, age average of 52,12 52,12±5,52 year, sedentary and with screening of arterial hypertension, volunteered to participate this study. The variables identified to the conduction of the respective study were the blood pressure, physical activity level and stress of the subjects. Statistic treatment was compost for descriptive and inferential analysis across of the variance analysis test (ANOVA two-way, concomitant with Post hoc test of Tukey, to estimate the differences in the average of the variables during the diverse moments of test. Kuskal-Wallis test was realized to compare the replies of the stress questionnaire. A value of p

  8. Cytomegalovirus infection causes an increase of arterial blood pressure.

    Directory of Open Access Journals (Sweden)

    Jilin Cheng

    2009-05-01

    Full Text Available Cytomegalovirus (CMV infection is a common infection in adults (seropositive 60-99% globally, and is associated with cardiovascular diseases, in line with risk factors such as hypertension and atherosclerosis. Several viral infections are linked to hypertension, including human herpes virus 8 (HHV-8 and HIV-1. The mechanisms of how viral infection contributes to hypertension or increased blood pressure are not defined. In this report, the role of CMV infection as a cause of increased blood pressure and in forming aortic atherosclerotic plaques is examined. Using in vivo mouse model and in vitro molecular biology analyses, we find that CMV infection alone caused a significant increase in arterial blood pressure (ABp (p<0.01 approximately 0.05, measured by microtip catheter technique. This increase in blood pressure by mouse CMV (MCMV was independent of atherosclerotic plaque formation in the aorta, defined by histological analyses. MCMV DNA was detected in blood vessel samples of viral infected mice but not in the control mice by nested PCR assay. MCMV significantly increased expression of pro-inflammatory cytokines IL-6, TNF-alpha, and MCP-1 in mouse serum by enzyme-linked immunosorbent assay (ELISA. Using quantitative real time reverse transcriptase PCR (Q-RT-PCR and Western blot, we find that CMV stimulated expression of renin in mouse and human cells in an infectious dose-dependent manner. Co-staining and immunofluorescent microscopy analyses showed that MCMV infection stimulated renin expression at a single cell level. Further examination of angiotensin-II (Ang II in mouse serum and arterial tissues with ELISA showed an increased expression of Ang II by MCMV infection. Consistent with the findings of the mouse trial, human CMV (HCMV infection of blood vessel endothelial cells (EC induced renin expression in a non-lytic infection manner. Viral replication kinetics and plaque formation assay showed that an active, CMV persistent infection in

  9. A pitfall in the measurement of arterial blood pressure in the ischaemic limb during elevation

    DEFF Research Database (Denmark)

    Bülow, J; Jelnes, Rolf

    1987-01-01

    In order to evaluate if elevation of the ischaemic limb above heart level is an alternative to the conventionally applied method with external counterpressure for estimation of skin perfusion pressure, femoral and popliteal artery pressures were measured directly in eight patients with occlusion...... of the superficial femoral artery. The measurements were done in the horizontal position and during elevation of the calf above heart level. During elevation relative blood flow, measured by arterio-venous oxygen saturation differences, decreased compared with the horizontal position. In contrast the popliteal...... arterial pressure decreased only by 20% of the value expected from the degree of elevation of the calf above the level of the heart. Thus, it could be calculated that calf vascular resistance increased two- to three-fold on average during elevation. Four patients were reexamined with the venous pressure...

  10. [Chronobiology of blood pressure and chronopharmacotherapy of arterial hypertension].

    Science.gov (United States)

    Schmieder, R E; Bramlage, P; Schunkert, H

    2012-02-01

    Arterial blood pressure is subject to a circadian rhythm that results in a fall of blood pressure during the night. In patients with diabetes, renal insufficiency, left-ventricular hypertrophy, sleep apnea, hypertension of pregnancy, and different forms of secondary hypertension a nocturnal fall of blood pressure is even abandoned or reverted. Diagnosis is made using 24-h blood pressure measurement, which is however used not frequently enough for a clinical assessment or adjustment of therapy. An adaption of the selection or the time of administration of antihypertensive drugs with respect to the circadian rhythm is beneficial to control blood pressure and reduce cardiovascular morbidity. This is particularly true for patients with an a non- or inverted dipping blood pressure pattern, in which the bedtime dosing may result in a normalization of blood pressure and restoration of a normal circadian rhythm. The present manuscript reviews the chronopharmacotherapy of arterial hypertension and grant practical recommendations for their translation into clinical practice.

  11. Pressure-dependence of arterial stiffness: potential clinical implications.

    Science.gov (United States)

    Spronck, Bart; Heusinkveld, Maarten H G; Vanmolkot, Floris H; Roodt, Jos Op 't; Hermeling, Evelien; Delhaas, Tammo; Kroon, Abraham A; Reesink, Koen D

    2015-02-01

    Arterial stiffness measures such as pulse wave velocity (PWV) have a known dependence on actual blood pressure, requiring consideration in cardiovascular risk assessment and management. Given the impact of ageing on arterial wall structure, the pressure-dependence of PWV may vary with age. Using a noninvasive model-based approach, combining carotid artery echo-tracking and tonometry waveforms, we obtained pressure-area curves in 23 hypertensive patients at baseline and after 3 months of antihypertensive treatment. We predicted the follow-up PWV decrease using modelled baseline curves and follow-up pressures. In addition, on the basis of these curves, we estimated PWV values for two age groups (mean ages 41 and 64 years) at predefined hypertensive (160/90 mmHg) and normotensive (120/80 mmHg) pressure ranges. Follow-up measurements showed a near 1 m/s decrease in carotid PWV when compared with baseline, which fully agreed with our model-prediction given the roughly 10 mmHg decrease in diastolic pressure. The stiffness-blood pressure-age pattern was in close agreement with corresponding data from the 'Reference Values for Arterial Stiffness' study, linking the physical and empirical bases of our findings. Our study demonstrates that the innate pressure-dependence of arterial stiffness may have implications for the clinical use of arterial stiffness measurements, both in risk assessment and in treatment monitoring of individual patients. We propose a number of clinically feasible approaches to account for the blood pressure effect on PWV measurements.

  12. Heart and Artery Damage and High Blood Pressure

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More How High Blood Pressure Can Lead to a Heart Attack Updated:Dec ... sheet This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  13. Genome-wide association study identifies six new loci influencing pulse pressure and mean arterial pressure

    NARCIS (Netherlands)

    Wain, Louise V.; Verwoert, Germaine C.; O'Reilly, Paul F.; Shi, Gang; Johnson, Toby; Johnson, Andrew D.; Bochud, Murielle; Rice, Kenneth M.; Henneman, Peter; Smith, Albert V.; Ehret, Georg B.; Amin, Najaf; Larson, Martin G.; Mooser, Vincent; Hadley, David; Doerr, Marcus; Bis, Joshua C.; Aspelund, Thor; Esko, Tonu; Janssens, A. Cecile J. W.; Zhao, Jing Hua; Heath, Simon; Laan, Maris; Fu, Jingyuan; Pistis, Giorgio; Luan, Jian'an; Arora, Pankaj; Lucas, Gavin; Pirastu, Nicola; Pichler, Irene; Jackson, Anne U.; Webster, Rebecca J.; Zhang, Feng; Peden, John F.; Schmidt, Helena; Tanaka, Toshiko; Campbell, Harry; Igl, Wilmar; Milaneschi, Yuri; Hottenga, Jouke-Jan; Vitart, Veronique; Chasman, Daniel I.; Trompet, Stella; Bragg-Gresham, Jennifer L.; Alizadeh, Behrooz Z.; Chambers, John C.; Guo, Xiuqing; Lehtimaki, Terho; Kuehnel, Brigitte; Lopez, Lorna M.; Polasek, Ozren; Boban, Mladen; Nelson, Christopher P.; Morrison, Alanna C.; Pihur, Vasyl; Ganesh, Santhi K.; Hofman, Albert; Kundu, Suman; Mattace-Raso, Francesco U. S.; Rivadeneira, Fernando; Sijbrands, Eric J. G.; Uitterlinden, Andre G.; Hwang, Shih-Jen; Vasan, Ramachandran S.; Wang, Thomas J.; Bergmann, Sven; Vollenweider, Peter; Waeber, Gerard; Laitinen, Jaana; Pouta, Anneli; Zitting, Paavo; McArdle, Wendy L.; Kroemer, Heyo K.; Voelker, Uwe; Voelzke, Henry; Glazer, Nicole L.; Taylor, Kent D.; Harris, Tamara B.; Alavere, Helene; Haller, Toomas; Keis, Aime; Tammesoo, Mari-Liis; Aulchenko, Yurii; Barroso, Ines; Khaw, Kay-Tee; Galan, Pilar; Hercberg, Serge; Lathrop, Mark; Eyheramendy, Susana; Org, Elin; Sober, Siim; Lu, Xiaowen; Nolte, Ilja M.; Penninx, Brenda W.; Corre, Tanguy; Masciullo, Corrado; Sala, Cinzia; Groop, Leif; Voight, Benjamin F.; Melander, Olle; O'Donnell, Christopher J.; Salomaa, Veikko; d'Adamo, Adamo Pio; Fabretto, Antonella; Faletra, Flavio; Ulivi, Sheila; Del Greco, Fabiola M.; Facheris, Maurizio; Collins, Francis S.; Bergman, Richard N.; Beilby, John P.; Hung, Joseph; Musk, A. William; Mangino, Massimo; Shin, So-Youn; Soranzo, Nicole; Watkins, Hugh; Goel, Anuj; Hamsten, Anders; Gider, Pierre; Loitfelder, Marisa; Zeginigg, Marion; Hernandez, Dena; Najjar, Samer S.; Navarro, Pau; Wild, Sarah H.; Corsi, Anna Maria; Singleton, Andrew; de Geus, Eco J. C.; Willemsen, Gonneke; Parker, Alex N.; Rose, Lynda M.; Buckley, Brendan; Stott, David; Orru, Marco; Uda, Manuela; van der Klauw, Melanie M.; Zhang, Weihua; Li, Xinzhong; Scott, James; Chen, Yii-Der Ida; Burke, Gregory L.; Kahonen, Mika; Viikari, Jorma; Doering, Angela; Meitinger, Thomas; Davies, Gail; Starr, John M.; Emilsson, Valur; Plump, Andrew; Lindeman, Jan H.; 't Hoen, Peter A. C.; Koenig, Inke R.; Felix, Janine F.; Clarke, Robert; Hopewell, Jemma C.; Ongen, Halit; Breteler, Monique; Debette, Stephanie; DeStefano, Anita L.; Fornage, Myriam; Mitchell, Gary F.; Smith, Nicholas L.; Holm, Hilma; Stefansson, Kari; Thorleifsson, Gudmar; Thorsteinsdottir, Unnur; Samani, Nilesh J.; Preuss, Michael; Rudan, Igor; Hayward, Caroline; Deary, Ian J.; Wichmann, H-Erich; Raitakari, Olli T.; Palmas, Walter; Kooner, Jaspal S.; Stolk, Ronald P.; Jukema, J. Wouter; Wright, Alan F.; Boomsma, Dorret I.; Bandinelli, Stefania; Gyllensten, Ulf B.; Wilson, James F.; Ferrucci, Luigi; Schmidt, Reinhold; Farrall, Martin; Spector, Tim D.; Palmer, Lyle J.; Tuomilehto, Jaakko; Pfeufer, Arne; Gasparini, Paolo; Siscovick, David; Altshuler, David; Loos, Ruth J. F.; Toniolo, Daniela; Snieder, Harold; Gieger, Christian; Meneton, Pierre; Wareham, Nicholas J.; Oostra, Ben A.; Metspalu, Andres; Launer, Lenore; Rettig, Rainer; Strachan, David P.; Beckmann, Jacques S.; Witteman, Jacqueline C. M.; Erdmann, Jeanette; van Dijk, Ko Willems; Boerwinkle, Eric; Boehnke, Michael; Ridker, Paul M.; Jarvelin, Marjo-Riitta; Chakravarti, Aravinda; Abecasis, Goncalo R.; Gudnason, Vilmundur; Newton-Cheh, Christopher; Levy, Daniel; Munroe, Patricia B.; Psaty, Bruce M.; Caulfield, Mark J.; Rao, Dabeeru C.; Tobin, Martin D.; Elliott, Paul; van Duijn, Cornelia M.

    2011-01-01

    Numerous genetic loci have been associated with systolic blood pressure (SBP) and diastolic blood pressure (DBP) in Europeans(1-3). We now report genome-wide association studies of pulse pressure (PP) and mean arterial pressure (MAP). In discovery (N = 74,064) and follow-up studies (N = 48,607), we

  14. Genome-wide association study identifies six new loci influencing pulse pressure and mean arterial pressure

    NARCIS (Netherlands)

    L.V. Wain (Louise); G.C. Verwoert (Germaine); P.F. O'Reilly (Paul); G. Shi (Gang); T. Johnson (Toby); M. Bochud (Murielle); K. Rice (Kenneth); P. Henneman (Peter); A.V. Smith (Albert Vernon); G.B. Ehret (Georg); N. Amin (Najaf); M.G. Larson (Martin); V. Mooser (Vincent); D. Hadley (David); M. Dörr (Marcus); J.C. Bis (Joshua); T. Aspelund (Thor); T. Esko (Tõnu); A.C.J.W. Janssens (Cécile); J.H. Zhao; S.C. Heath (Simon); M. Laan (Maris); J. Fu (Jingyuan); G. Pistis (Giorgio); J. Luan; G. Lucas (Gavin); N. Pirastu (Nicola); I. Pichler (Irene); A.U. Jackson (Anne); R.J. Webster (Rebecca J.); F.F. Zhang; J. Peden (John); R. Schmidt (Reinhold); T. Tanaka (Toshiko); H. Campbell (Harry); W. Igl (Wilmar); Y. Milaneschi (Yuri); J.J. Hottenga (Jouke Jan); V. Vitart (Veronique); D.I. Chasman (Daniel); S. Trompet (Stella); J.L. Bragg-Gresham (Jennifer L.); B.Z. Alizadeh (Behrooz); J.C. Chambers (John); X. Guo (Xiuqing); T. Lehtimäki (Terho); B. Kuhnel (Brigitte); L.M. Lopez; O. Polasek (Ozren); M. Boban (Mladen); C.P. Nelson (Christopher P.); A.C. Morrison (Alanna); V. Pihur (Vasyl); S.K. Ganesh (Santhi); A. Hofman (Albert); S. Kundu (Suman); F.U.S. Mattace Raso (Francesco); F. Rivadeneira Ramirez (Fernando); E.J.G. Sijbrands (Eric); A.G. Uitterlinden (André); S.J. Hwang; R.S. Vasan (Ramachandran Srini); Y.A. Wang (Ying); S.M. Bergmann (Sven); P. Vollenweider (Peter); G. Waeber (Gérard); J. Laitinen (Jaana); A. Pouta (Anneli); P. Zitting (Paavo); W.L. McArdle (Wendy); H.K. Kroemer (Heyo); U. Völker (Uwe); H. Völzke (Henry); N.L. Glazer (Nicole); K.D. Taylor (Kent); T.B. Harris (Tamara); H. Alavere (Helene); T. Haller (Toomas); A. Keis (Aime); M.L. Tammesoo; Y.S. Aulchenko (Yurii); K-T. Khaw (Kay-Tee); P. Galan (Pilar); S. Hercberg (Serge); G.M. Lathrop (Mark); S. Eyheramendy (Susana); E. Org (Elin); S. Sõber (Siim); X. Lu (Xiaowen); I.M. Nolte (Ilja); B.W.J.H. Penninx (Brenda); T. Corre (Tanguy); C. Masciullo (Corrado); C. Sala (Cinzia); L. Groop (Leif); B.F. Voight (Benjamin); O. Melander (Olle); C.J. O'Donnell (Christopher); V. Salomaa (Veikko); P. d' Adamo (Pio); A. Fabretto (Antonella); F. Faletra (Flavio); S. Ulivi (Shelia); F. Del Greco M (Fabiola); M.F. Facheris (Maurizio); F.S. Collins (Francis); R.N. Bergman (Richard); J.P. Beilby (John); J. Hung (Judy); A.W. Musk (Arthur); M. Mangino (Massimo); S.Y. Shin (So Youn); N. Soranzo (Nicole); H. Watkins (Hugh); A. Goel (Anuj); A. Hamsten (Anders); P. Gider (Pierre); M. Loitfelder (Marisa); M. Zeginigg (Marion); D.G. Hernandez (Dena); S.S. Najjar (Samer); P. Navarro (Pau); S.H. Wild (Sarah); A.M. Corsi (Anna Maria); A. Singleton (Andrew); E.J.C. de Geus (Eco); G.A.H.M. Willemsen (Gonneke); A.N. Parker (Alex); L.M. Rose (Lynda); B.M. Buckley (Brendan M.); D.J. Stott (David. J.); M. Orrù (Marco); M. Uda (Manuela); M.M. van der Klauw (Melanie); X. Li (Xiaohui); J. Scott (James); Y.D.I. Chen (Yii-Der Ida); G.L. Burke (Greg); M. Kähönen (Mika); J. Viikari (Jorma); A. Döring (Angela); T. Meitinger (Thomas); G.S. Davis; J.M. Starr (John); V. Emilsson (Valur); A.S. Plump (Andrew); J.H. Lindeman (Jan H.); P.A.C. 't Hoen (Peter); I.R. König (Inke); J.F. Felix (Janine); R. Clarke; J. Hopewell; H. Ongen (Halit); M.M.B. Breteler (Monique); S. Debette (Stéphanie); A.L. DeStefano (Anita); M. Fornage (Myriam); G.F. Mitchell (Gary); H. Holm (Hilma); K. Stefansson (Kari); G. Thorleifsson (Gudmar); U. Thorsteinsdottir (Unnur); N.J. Samani (Nilesh); M. Preuss (Michael); I. Rudan (Igor); C. Hayward (Caroline); I.J. Deary (Ian); H.E. Wichmann (Heinz Erich); O. Raitakari (Olli); W. Palmas (Walter); J.S. Kooner (Jaspal); R.P. Stolk (Ronald); J.W. Jukema (Jan Wouter); A.F. Wright (Alan); D.I. Boomsma (Dorret); S. Bandinelli (Stefania); U. Gyllensten (Ulf); J.F. Wilson (James); L. Ferrucci (Luigi); M. Farrall (Martin); T.D. Spector (Timothy); L.J. Palmer; J. Tuomilehto (Jaakko); A. Pfeufer (Arne); P. Gasparini (Paolo); D.S. Siscovick (David); D. Altshuler (David); R.J.F. Loos (Ruth); D. Toniolo (Daniela); H. Snieder (Harold); C. Gieger (Christian); P. Meneton (Pierre); N.J. Wareham (Nick); B.A. Oostra (Ben); A. Metspalu (Andres); L.J. Launer (Lenore); R. Rettig (Rainer); D.P. Strachan (David); J.S. Beckmann (Jacques); J.C.M. Witteman (Jacqueline); J.A.P. Willems van Dijk (Ko); E.A. Boerwinkle (Eric); M. Boehnke (Michael); P.M. Ridker (Paul); M.R. Järvelin; A. Chakravarti (Aravinda); J. Erdmann (Jeanette); V. Gudnason (Vilmundur); C. Newton-Cheh (Christopher); D. Levy (Daniel); P. Arora (Pankaj)

    2011-01-01

    textabstractNumerous genetic loci have been associated with systolic blood pressure (SBP) and diastolic blood pressure (DBP) in Europeans. We now report genome-wide association studies of pulse pressure (PP) and mean arterial pressure (MAP). In discovery (N = 74,064) and follow-up studies (N =

  15. Genome-wide association study identifies six new loci influencing pulse pressure and mean arterial pressure

    NARCIS (Netherlands)

    Wain, Louise V; Verwoert, Germaine C; O'Reilly, Paul F; Shi, Gang; Johnson, Toby; Johnson, Andrew D; Bochud, Murielle; Rice, Kenneth M; Henneman, Peter; Smith, Albert V; Ehret, Georg B; Amin, Najaf; Larson, Martin G; Mooser, Vincent; Hadley, David; Dörr, Marcus; Bis, Joshua C; Aspelund, Thor; Esko, Tõnu; Janssens, A Cecile J W; Zhao, Jing Hua; Heath, Simon; Laan, Maris; Fu, Jingyuan; Pistis, Giorgio; Luan, Jian'an; Arora, Pankaj; Lucas, Gavin; Pirastu, Nicola; Pichler, Irene; Jackson, Anne U; Webster, Rebecca J; Zhang, Feng; Peden, John F; Schmidt, Helena; Tanaka, Toshiko; Campbell, Harry; Igl, Wilmar; Milaneschi, Yuri; Hottenga, Jouke-Jan; Vitart, Veronique; Chasman, Daniel I; Trompet, Stella; Bragg-Gresham, Jennifer L; Alizadeh, Behrooz Z; Chambers, John C; Guo, Xiuqing; Lehtimäki, Terho; Kühnel, Brigitte; Lopez, Lorna M; Polašek, Ozren; Boban, Mladen; Nelson, Christopher P; Morrison, Alanna C; Pihur, Vasyl; Ganesh, Santhi K; Hofman, Albert; Kundu, Suman; Mattace-Raso, Francesco U S; Rivadeneira, Fernando; Sijbrands, Eric J G; Uitterlinden, Andre G; Hwang, Shih-Jen; Vasan, Ramachandran S; Wang, Thomas J; Bergmann, Sven; Vollenweider, Peter; Waeber, Gérard; Laitinen, Jaana; Pouta, Anneli; Zitting, Paavo; McArdle, Wendy L; Kroemer, Heyo K; Völker, Uwe; Völzke, Henry; Glazer, Nicole L; Taylor, Kent D; Harris, Tamara B; Alavere, Helene; Haller, Toomas; Keis, Aime; Tammesoo, Mari-Liis; Aulchenko, Yurii; Barroso, Inês; Khaw, Kay-Tee; Galan, Pilar; Hercberg, Serge; Lathrop, Mark; Eyheramendy, Susana; Org, Elin; Sõber, Siim; Lu, Xiaowen; Nolte, Ilja M; Penninx, Brenda W; Corre, Tanguy; Masciullo, Corrado; Sala, Cinzia; Groop, Leif; Voight, Benjamin F; Melander, Olle; O'Donnell, Christopher J; Salomaa, Veikko; d'Adamo, Adamo Pio; Fabretto, Antonella; Faletra, Flavio; Ulivi, Sheila; Del Greco, Fabiola M; Facheris, Maurizio; Collins, Francis S; Bergman, Richard N; Beilby, John P; Hung, Joseph; Musk, A William; Mangino, Massimo; Shin, So-Youn; Soranzo, Nicole; Watkins, Hugh; Goel, Anuj; Hamsten, Anders; Gider, Pierre; Loitfelder, Marisa; Zeginigg, Marion; Hernandez, Dena; Najjar, Samer S; Navarro, Pau; Wild, Sarah H; Corsi, Anna Maria; Singleton, Andrew; de Geus, Eco J C; Willemsen, Gonneke; Parker, Alex N; Rose, Lynda M; Buckley, Brendan; Stott, David; Orru, Marco; Uda, Manuela; van der Klauw, Melanie M; Zhang, Weihua; Li, Xinzhong; Scott, James; Chen, Yii-Der Ida; Burke, Gregory L; Kähönen, Mika; Viikari, Jorma; Döring, Angela; Meitinger, Thomas; Davies, Gail; Starr, John M; Emilsson, Valur; Plump, Andrew; Lindeman, Jan H; Hoen, Peter A C 't; König, Inke R; Felix, Janine F; Clarke, Robert; Hopewell, Jemma C; Ongen, Halit; Breteler, Monique; Debette, Stéphanie; Destefano, Anita L; Fornage, Myriam; Mitchell, Gary F; Smith, Nicholas L; Holm, Hilma; Stefansson, Kari; Thorleifsson, Gudmar; Thorsteinsdottir, Unnur; Samani, Nilesh J; Preuss, Michael; Rudan, Igor; Hayward, Caroline; Deary, Ian J; Wichmann, H-Erich; Raitakari, Olli T; Palmas, Walter; Kooner, Jaspal S; Stolk, Ronald P; Jukema, J Wouter; Wright, Alan F; Boomsma, Dorret I; Bandinelli, Stefania; Gyllensten, Ulf B; Wilson, James F; Ferrucci, Luigi; Schmidt, Reinhold; Farrall, Martin; Spector, Tim D; Palmer, Lyle J; Tuomilehto, Jaakko; Pfeufer, Arne; Gasparini, Paolo; Siscovick, David; Altshuler, David; Loos, Ruth J F; Toniolo, Daniela; Snieder, Harold; Gieger, Christian; Meneton, Pierre; Wareham, Nicholas J; Oostra, Ben A; Metspalu, Andres; Launer, Lenore; Rettig, Rainer; Strachan, David P; Beckmann, Jacques S; Witteman, Jacqueline C M; Erdmann, Jeanette; van Dijk, Ko Willems; Boerwinkle, Eric; Boehnke, Michael; Ridker, Paul M; Jarvelin, Marjo-Riitta; Chakravarti, Aravinda; Abecasis, Goncalo R; Gudnason, Vilmundur; Newton-Cheh, Christopher; Levy, Daniel; Munroe, Patricia B; Psaty, Bruce M; Caulfield, Mark J; Rao, Dabeeru C; Tobin, Martin D; Elliott, Paul; van Duijn, Cornelia M

    2011-01-01

    Numerous genetic loci have been associated with systolic blood pressure (SBP) and diastolic blood pressure (DBP) in Europeans. We now report genome-wide association studies of pulse pressure (PP) and mean arterial pressure (MAP). In discovery (N = 74,064) and follow-up studies (N = 48,607), we ident

  16. Genome-wide association study identifies six new loci influencing pulse pressure and mean arterial pressure

    NARCIS (Netherlands)

    Wain, Louise V.; Verwoert, Germaine C.; O'Reilly, Paul F.; Shi, Gang; Johnson, Toby; Johnson, Andrew D.; Bochud, Murielle; Rice, Kenneth M.; Henneman, Peter; Smith, Albert V.; Ehret, Georg B.; Amin, Najaf; Larson, Martin G.; Mooser, Vincent; Hadley, David; Doerr, Marcus; Bis, Joshua C.; Aspelund, Thor; Esko, Tonu; Janssens, A. Cecile J. W.; Zhao, Jing Hua; Heath, Simon; Laan, Maris; Fu, Jingyuan; Pistis, Giorgio; Luan, Jian'an; Arora, Pankaj; Lucas, Gavin; Pirastu, Nicola; Pichler, Irene; Jackson, Anne U.; Webster, Rebecca J.; Zhang, Feng; Peden, John F.; Schmidt, Helena; Tanaka, Toshiko; Campbell, Harry; Igl, Wilmar; Milaneschi, Yuri; Hottenga, Jouke-Jan; Vitart, Veronique; Chasman, Daniel I.; Trompet, Stella; Bragg-Gresham, Jennifer L.; Alizadeh, Behrooz Z.; Chambers, John C.; Guo, Xiuqing; Lehtimaki, Terho; Kuehnel, Brigitte; Lopez, Lorna M.; Polasek, Ozren; Boban, Mladen; Nelson, Christopher P.; Morrison, Alanna C.; Pihur, Vasyl; Ganesh, Santhi K.; Hofman, Albert; Kundu, Suman; Mattace-Raso, Francesco U. S.; Rivadeneira, Fernando; Sijbrands, Eric J. G.; Uitterlinden, Andre G.; Hwang, Shih-Jen; Vasan, Ramachandran S.; Wang, Thomas J.; Bergmann, Sven; Vollenweider, Peter; Waeber, Gerard; Laitinen, Jaana; Pouta, Anneli; Zitting, Paavo; McArdle, Wendy L.; Kroemer, Heyo K.; Voelker, Uwe; Voelzke, Henry; Glazer, Nicole L.; Taylor, Kent D.; Harris, Tamara B.; Alavere, Helene; Haller, Toomas; Keis, Aime; Tammesoo, Mari-Liis; Aulchenko, Yurii; Barroso, Ines; Khaw, Kay-Tee; Galan, Pilar; Hercberg, Serge; Lathrop, Mark; Eyheramendy, Susana; Org, Elin; Sober, Siim; Lu, Xiaowen; Nolte, Ilja M.; Penninx, Brenda W.; Corre, Tanguy; Masciullo, Corrado; Sala, Cinzia; Groop, Leif; Voight, Benjamin F.; Melander, Olle; O'Donnell, Christopher J.; Salomaa, Veikko; d'Adamo, Adamo Pio; Fabretto, Antonella; Faletra, Flavio; Ulivi, Sheila; Del Greco, Fabiola M.; Facheris, Maurizio; Collins, Francis S.; Bergman, Richard N.; Beilby, John P.; Hung, Joseph; Musk, A. William; Mangino, Massimo; Shin, So-Youn; Soranzo, Nicole; Watkins, Hugh; Goel, Anuj; Hamsten, Anders; Gider, Pierre; Loitfelder, Marisa; Zeginigg, Marion; Hernandez, Dena; Najjar, Samer S.; Navarro, Pau; Wild, Sarah H.; Corsi, Anna Maria; Singleton, Andrew; de Geus, Eco J. C.; Willemsen, Gonneke; Parker, Alex N.; Rose, Lynda M.; Buckley, Brendan; Stott, David; Orru, Marco; Uda, Manuela; van der Klauw, Melanie M.; Zhang, Weihua; Li, Xinzhong; Scott, James; Chen, Yii-Der Ida; Burke, Gregory L.; Kahonen, Mika; Viikari, Jorma; Doering, Angela; Meitinger, Thomas; Davies, Gail; Starr, John M.; Emilsson, Valur; Plump, Andrew; Lindeman, Jan H.; 't Hoen, Peter A. C.; Koenig, Inke R.; Felix, Janine F.; Clarke, Robert; Hopewell, Jemma C.; Ongen, Halit; Breteler, Monique; Debette, Stephanie; DeStefano, Anita L.; Fornage, Myriam; Mitchell, Gary F.; Smith, Nicholas L.; Holm, Hilma; Stefansson, Kari; Thorleifsson, Gudmar; Thorsteinsdottir, Unnur; Samani, Nilesh J.; Preuss, Michael; Rudan, Igor; Hayward, Caroline; Deary, Ian J.; Wichmann, H-Erich; Raitakari, Olli T.; Palmas, Walter; Kooner, Jaspal S.; Stolk, Ronald P.; Jukema, J. Wouter; Wright, Alan F.; Boomsma, Dorret I.; Bandinelli, Stefania; Gyllensten, Ulf B.; Wilson, James F.; Ferrucci, Luigi; Schmidt, Reinhold; Farrall, Martin; Spector, Tim D.; Palmer, Lyle J.; Tuomilehto, Jaakko; Pfeufer, Arne; Gasparini, Paolo; Siscovick, David; Altshuler, David; Loos, Ruth J. F.; Toniolo, Daniela; Snieder, Harold; Gieger, Christian; Meneton, Pierre; Wareham, Nicholas J.; Oostra, Ben A.; Metspalu, Andres; Launer, Lenore; Rettig, Rainer; Strachan, David P.; Beckmann, Jacques S.; Witteman, Jacqueline C. M.; Erdmann, Jeanette; van Dijk, Ko Willems; Boerwinkle, Eric; Boehnke, Michael; Ridker, Paul M.; Jarvelin, Marjo-Riitta; Chakravarti, Aravinda; Abecasis, Goncalo R.; Gudnason, Vilmundur; Newton-Cheh, Christopher; Levy, Daniel; Munroe, Patricia B.; Psaty, Bruce M.; Caulfield, Mark J.; Rao, Dabeeru C.; Tobin, Martin D.; Elliott, Paul; van Duijn, Cornelia M.

    2011-01-01

    Numerous genetic loci have been associated with systolic blood pressure (SBP) and diastolic blood pressure (DBP) in Europeans(1-3). We now report genome-wide association studies of pulse pressure (PP) and mean arterial pressure (MAP). In discovery (N = 74,064) and follow-up studies (N = 48,607), we

  17. Genome-wide association study identifies six new loci influencing pulse pressure and mean arterial pressure

    NARCIS (Netherlands)

    L.V. Wain (Louise); G.C. Verwoert (Germaine); P.F. O'Reilly (Paul); G. Shi (Gang); T. Johnson (Toby); M. Bochud (Murielle); K. Rice (Kenneth); P. Henneman (Peter); A.V. Smith (Albert Vernon); G.B. Ehret (Georg); N. Amin (Najaf); M.G. Larson (Martin); V. Mooser (Vincent); D. Hadley (David); M. Dörr (Marcus); J.C. Bis (Joshua); T. Aspelund (Thor); T. Esko (Tõnu); A.C.J.W. Janssens (Cécile); J.H. Zhao; S.C. Heath (Simon); M. Laan (Maris); J. Fu (Jingyuan); G. Pistis (Giorgio); J. Luan; G. Lucas (Gavin); N. Pirastu (Nicola); I. Pichler (Irene); A.U. Jackson (Anne); R.J. Webster (Rebecca J.); F.F. Zhang; J. Peden (John); R. Schmidt (Reinhold); T. Tanaka (Toshiko); H. Campbell (Harry); W. Igl (Wilmar); Y. Milaneschi (Yuri); J.J. Hottenga (Jouke Jan); V. Vitart (Veronique); D.I. Chasman (Daniel); S. Trompet (Stella); J.L. Bragg-Gresham (Jennifer L.); B.Z. Alizadeh (Behrooz); J.C. Chambers (John); X. Guo (Xiuqing); T. Lehtimäki (Terho); B. Kuhnel (Brigitte); L.M. Lopez; O. Polasek (Ozren); M. Boban (Mladen); C.P. Nelson (Christopher P.); A.C. Morrison (Alanna); V. Pihur (Vasyl); S.K. Ganesh (Santhi); A. Hofman (Albert); S. Kundu (Suman); F.U.S. Mattace Raso (Francesco); F. Rivadeneira Ramirez (Fernando); E.J.G. Sijbrands (Eric); A.G. Uitterlinden (André); S.J. Hwang; R.S. Vasan (Ramachandran Srini); Y.A. Wang (Ying); S.M. Bergmann (Sven); P. Vollenweider (Peter); G. Waeber (Gérard); J. Laitinen (Jaana); A. Pouta (Anneli); P. Zitting (Paavo); W.L. McArdle (Wendy); H.K. Kroemer (Heyo); U. Völker (Uwe); H. Völzke (Henry); N.L. Glazer (Nicole); K.D. Taylor (Kent); T.B. Harris (Tamara); H. Alavere (Helene); T. Haller (Toomas); A. Keis (Aime); M.L. Tammesoo; Y.S. Aulchenko (Yurii); K-T. Khaw (Kay-Tee); P. Galan (Pilar); S. Hercberg (Serge); G.M. Lathrop (Mark); S. Eyheramendy (Susana); E. Org (Elin); S. Sõber (Siim); X. Lu (Xiaowen); I.M. Nolte (Ilja); B.W.J.H. Penninx (Brenda); T. Corre (Tanguy); C. Masciullo (Corrado); C. Sala (Cinzia); L. Groop (Leif); B.F. Voight (Benjamin); O. Melander (Olle); C.J. O'Donnell (Christopher); V. Salomaa (Veikko); P. d' Adamo (Pio); A. Fabretto (Antonella); F. Faletra (Flavio); S. Ulivi (Shelia); F. Del Greco M (Fabiola); M.F. Facheris (Maurizio); F.S. Collins (Francis); R.N. Bergman (Richard); J.P. Beilby (John); J. Hung (Judy); A.W. Musk (Arthur); M. Mangino (Massimo); S.Y. Shin (So Youn); N. Soranzo (Nicole); H. Watkins (Hugh); A. Goel (Anuj); A. Hamsten (Anders); P. Gider (Pierre); M. Loitfelder (Marisa); M. Zeginigg (Marion); D.G. Hernandez (Dena); S.S. Najjar (Samer); P. Navarro (Pau); S.H. Wild (Sarah); A.M. Corsi (Anna Maria); A. Singleton (Andrew); E.J.C. de Geus (Eco); G.A.H.M. Willemsen (Gonneke); A.N. Parker (Alex); L.M. Rose (Lynda); B.M. Buckley (Brendan M.); D.J. Stott (David. J.); M. Orrù (Marco); M. Uda (Manuela); M.M. van der Klauw (Melanie); X. Li (Xiaohui); J. Scott (James); Y.D.I. Chen (Yii-Der Ida); G.L. Burke (Greg); M. Kähönen (Mika); J. Viikari (Jorma); A. Döring (Angela); T. Meitinger (Thomas); G.S. Davis; J.M. Starr (John); V. Emilsson (Valur); A.S. Plump (Andrew); J.H. Lindeman (Jan H.); P.A.C. 't Hoen (Peter); I.R. König (Inke); J.F. Felix (Janine); R. Clarke; J. Hopewell; H. Ongen (Halit); M.M.B. Breteler (Monique); S. Debette (Stéphanie); A.L. DeStefano (Anita); M. Fornage (Myriam); G.F. Mitchell (Gary); H. Holm (Hilma); K. Stefansson (Kari); G. Thorleifsson (Gudmar); U. Thorsteinsdottir (Unnur); N.J. Samani (Nilesh); M. Preuss (Michael); I. Rudan (Igor); C. Hayward (Caroline); I.J. Deary (Ian); H.E. Wichmann (Heinz Erich); O. Raitakari (Olli); W. Palmas (Walter); J.S. Kooner (Jaspal); R.P. Stolk (Ronald); J.W. Jukema (Jan Wouter); A.F. Wright (Alan); D.I. Boomsma (Dorret); S. Bandinelli (Stefania); U. Gyllensten (Ulf); J.F. Wilson (James); L. Ferrucci (Luigi); M. Farrall (Martin); T.D. Spector (Timothy); L.J. Palmer; J. Tuomilehto (Jaakko); A. Pfeufer (Arne); P. Gasparini (Paolo); D.S. Siscovick (David); D. Altshuler (David); R.J.F. Loos (Ruth); D. Toniolo (Daniela); H. Snieder (Harold); C. Gieger (Christian); P. Meneton (Pierre); N.J. Wareham (Nick); B.A. Oostra (Ben); A. Metspalu (Andres); L.J. Launer (Lenore); R. Rettig (Rainer); D.P. Strachan (David); J.S. Beckmann (Jacques); J.C.M. Witteman (Jacqueline); J.A.P. Willems van Dijk (Ko); E.A. Boerwinkle (Eric); M. Boehnke (Michael); P.M. Ridker (Paul); M.R. Järvelin; A. Chakravarti (Aravinda); J. Erdmann (Jeanette); V. Gudnason (Vilmundur); C. Newton-Cheh (Christopher); D. Levy (Daniel); P. Arora (Pankaj); P. Munroe (Patricia); B.M. Psaty (Bruce); M. Caulfield (Mark); D.C. Rao (Dabeeru C.); P. Elliott (Paul); P. Tikka-Kleemola (Päivi); G.R. Abecasis (Gonçalo); I. Barroso (Inês)

    2011-01-01

    textabstractNumerous genetic loci have been associated with systolic blood pressure (SBP) and diastolic blood pressure (DBP) in Europeans. We now report genome-wide association studies of pulse pressure (PP) and mean arterial pressure (MAP). In discovery (N = 74,064) and follow-up studies (N = 48,60

  18. Broad band spectral analysis of 24 h continuous finger blood pressure: Comparison with intra-arterial recordings

    NARCIS (Netherlands)

    Castiglioni, P.; Parati, G.; Omboni, S.; Mancia, G.; Imholz, B.P.M.; Wesseling, K.H.; Rienzo, M. di

    1999-01-01

    The present study compares the spectral characteristics of 24-h blood pressure variability estimated invasively at the brachial artery level with those estimated by measurement of blood pressure at the finger artery using the non-invasive Portapres device. Broad-band spectra (from 3 x

  19. Accuracy of continuous noninvasive arterial pressure monitoring in living-liver donors during transplantation.

    Science.gov (United States)

    Araz, Coskun; Zeyneloglu, Pinar; Pirat, Arash; Veziroglu, Nukhet; Camkiran Firat, Aynur; Arslan, Gulnaz

    2015-04-01

    Hemodynamic monitoring is vital during liver transplant surgeries because distinct hemodynamic changes are expected. The continuous noninvasive arterial pressure (CNAP) monitor is a noninvasive device for continuous arterial pressure measurement by a tonometric method. This study compared continuous noninvasive arterial pressure monitoring with invasive direct arterial pressure monitoring in living-liver donors during transplant. There were 40 patients analyzed while undergoing hepatic lobectomy for liver transplant. Invasive pressure monitoring was established at the radial artery and continuous noninvasive arterial pressure monitoring using a finger sensor was recorded simultaneously from the contralateral arm. Systolic, diastolic, and mean arterial pressures from the 2 methods were compared. Correlation between the 2 methods was calculated. A total of 5433 simultaneous measurements were obtained. For systolic arterial blood pressure, 55% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.479, continuous noninvasive arterial pressure bias was -0.3 mm Hg, and limits of agreement were 32.0 mm Hg. For diastolic arterial blood pressure, 50% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.630, continuous noninvasive arterial pressure bias was -0.4 mm Hg, and limits of agreement were 21.1 mm Hg. For mean arterial blood pressure, 60% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.692, continuous noninvasive arterial pressure bias was +0.4 mm Hg, and limits of agreement were 20.8 mm Hg. The 2 monitoring techniques did not show acceptable agreement. Our results suggest that continuous noninvasive arterial pressure monitoring is not equivalent to invasive arterial pressure monitoring in donors during living-donor liver transplant.

  20. Central arterial pressure assessment with intensity POF sensor

    Science.gov (United States)

    Leitão, Cátia; Gonçalves, Steve; Antunes, Paulo; Bastos, José M.; Pinto, João. L.; André, Paulo

    2015-09-01

    The central pressure monitoring is considered a new key factor in hypertension assessment and cardiovascular prevention. In this work, it is presented the central arterial systolic pressure assessment with an intensity based POF sensor. The device was tested in four subjects, and stable pulse waves were obtained, allowing the calculation of the central pressure for all the subjects. The results shown that the sensor performs reliably, being a simple and low-cost solution to the intended application.

  1. Distal shift of arterial pressure wave reflection sites with aging.

    Science.gov (United States)

    Sugawara, Jun; Hayashi, Koichiro; Tanaka, Hirofumi

    2010-11-01

    An early return of reflected waves, the backward propagation of the arterial pressure wave from the periphery to the heart, is associated with the augmentation of central pulse pressure and cardiovascular risks. The locations of arterial pressure wave reflection, along with arterial stiffening, have a major influence on the timing of the reflected wave. To determine the influence of aging on the location of a major reflection site, arterial length (via 3D artery tracing of MRI) and central (carotid-femoral) and peripheral (femoral-ankle) pulse wave velocities were measured in 208 adults varying in age. The major reflection site was detected by carotid-femoral pulse wave velocity and the reflected wave transit time (via carotid arterial pressure wave analysis). The length from the aortic valve to the major reflection site (eg, effective reflecting length) significantly increased with aging. The effective reflecting length normalized by the arterial length demonstrated that the major reflection sites were located between the aortic bifurcation and femoral site in most of the subjects. The normalized effective reflecting length did not alter with aging until 65 years of age and increased remarkably thereafter in men and women. The effective reflecting length was significantly and positively associated with the difference between central and peripheral pulse wave velocities (r=0.76). This correlation remained significant even when the influence of aortic pulse wave velocity was partial out (r=0.35). These results suggest that the major reflection site shifts distally with aging partly because of the closer matching of impedance provided by central and peripheral arterial stiffness.

  2. Assembly of a Pulmonary Artery Pressure Sensor System

    Directory of Open Access Journals (Sweden)

    J. Müntjes

    2010-01-01

    Full Text Available This paper presents an implantable system for telemonitoring the intravascular pressure in the pulmonary artery. By implanting a catheter-bound pressure and temperature sensor into the pulmonary artery, it is possible to monitor the actual value and the time variations of the intravascular pressure with a frequency of 128 Hz. Thus hospitalization of patients suffering from heart insufficiency can be avoided by early changes in therapy.Preliminary in vivo experiments have been conducted to verify the fixation mechanism and the positioning of the sensor at the right place in the pulmonary artery. It was shown that the proposed fixation mechanism and the packaging of the sensor promise to be stable.

  3. Implantable blood pressure sensor for analyzing elasticity in arteries

    Science.gov (United States)

    Franco-Ayala, Marco; Martínez-Piñón, Fernando; Reyes-Barranca, Alfredo; Sánchez de la Peña, Salvador; Álvarez-Chavez, José A.

    2009-03-01

    MEMS technology could be an option for the development of a pressure sensor which allows the monitoring of several electronic signals in humans. In this work, a comparison is made between the typical elasticity curves of several arteries in the human body and the elasticity obtained for MEMS silicon microstructures such as membranes and cantilevers employing Finite Element analysis tools. The purpose is to identify which types of microstructures are mechanically compatible with human arteries. The goal is to integrate a blood pressure sensor which can be implanted in proximity with an artery. The expected benefits for this type of sensor are mainly to reduce the problems associated with the use of bulk devices through the day and during several days. Such a sensor could give precise blood pressure readings in a continuous or periodic form, i.e. information that is especially important for some critical cases of hypertension patients.

  4. Sex Differences in Peripheral Augmentation Index and Arterial Reservoir Pressure during Upper Limb Postural Shifts

    Directory of Open Access Journals (Sweden)

    Kevin S. Heffernan

    2014-01-01

    Full Text Available We examined the peripheral hemodynamic response to passive arm postural changes in young men and women. Radial artery pulse waveforms were captured using applanation tonometry in 20 men (age 27 ± 2 yrs, BMI 25 ± 1 kg/m2 and 20 women (age 27 ± 2 yrs, BMI 23±1 kg/m2. Arm position was maintained at either heart level or supported 14 cm above/below heart level in a randomized fashion. Systolic augmentation index (sAIx and diastolic augmentation index (dAIx were used as estimates of pressure from wave reflections arriving in systole and diastole, respectively. A novel reservoir-wave separation technique was used to obtain arterial reservoir pressure (pressure generated by arterial capacitance. Women showed a significant reduction in radial diastolic pressure-time integral (DPTI (P0.05 or dAIx (P>0.05 when moving the arm from below to above heart level. Conversely, men showed an attenuated change in radial DPTI (P>0.05 concomitant with significant increases in reservoir pressure (P<0.05, sAIx (P<0.05, and dAIx (P<0.05. Gravity-mediated changes in regional hemodynamics produced by passive arm postural shifts are sex specific. Men demonstrate less change in regional diastolic pressure concomitant with increased augmentation index and arterial reservoir pressure.

  5. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    were almost similar in the two groups (108 vs. 110; 65 vs. 67; 78 vs. 82 mm Hg, NS). Conversely, HR was significantly higher in the patients both in the daytime (86 vs. 72/min, P pressure and HR from daytime......Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P pressures...

  6. Modified lumbar artery perforator flaps for gluteal pressure sore reconstruction.

    Science.gov (United States)

    Yoon, Chi Sun; Yim, Ji Hong; Kim, Min Ho; Ha, Won; Kim, Kyu Nam

    2016-03-21

    Gluteal perforator flaps (GPFs) are the most useful for gluteal region pressure sore reconstruction. However, application is difficult if the surrounding area has scar tissue from previous operations or trauma, especially with recurrent sores. We describe the use of modified lumbar artery perforator flaps when GPFs cannot be used. Between May 2009 and April 2014, 51 patients underwent gluteal pressure sore reconstructions with gluteal (n = 39) or modified lumbar artery (n = 12) perforator flaps. Patients in the modified lumbar artery perforator group had scar tissue from trauma or previous surgery. In this retrospective review, we analyzed patient age and sex, defect size and location, operative time, follow-up duration, immediate postoperative issues, flap necrosis, dehiscence, re-operation, donor-site morbidity and recurrence. Complications and clinical outcomes were compared between groups. We found no significant differences in patient demographics, surgical complications or clinical outcomes. There were eight cases of temporary congestion (20.51%) and four of partial flap necrosis (10.25%) in the gluteal perforator group. In the modified lumbar artery perforator group, there were three cases of temporary congestion (25%) and one of partial flap necrosis (8.33%). No pressure sores recurred during follow-up in either group. GPFs are the gold standards for gluteal pressure sores, but modified lumbar artery perforator flaps are relatively easy and useful when GPFs cannot be used due to scar tissue. © 2016 Royal Australasian College of Surgeons.

  7. Medial circumflex femoral artery flap for ischial pressure sore

    Science.gov (United States)

    Palanivelu, S.

    2009-01-01

    A new axial pattern flap based on the terminal branches of the medial circumflex femoral artery is described for coverage of ischial pressure sore. Based on the terminal branches of the transverse branch of medial circumflex femoral artery, which exit through the gap between the quadratus femoris muscle above and the upper border of adductor magnus muscle below, this fascio cutaneous flap is much smaller than the posterior thigh flap but extremely useful to cover ischeal pressure sores. The skin redundancy below the gluteal fold allows a primary closure of the donor defect. It can also be used in combination with biceps femoris muscle flap. PMID:19881020

  8. Arterial pressure control for nursing military professionals

    Directory of Open Access Journals (Sweden)

    Jorge Luiz Lima da Silva

    2016-01-01

    Full Text Available Objetivo: Verificar quais os fatores de risco para a HAS que os profissionais militares da área de enfermagem identificam em seu estilo de vida; classificar os níveis pressóricos dos profissionais. Método: Quantitativo, embasado em pesquisa descritiva. Resultados: Participaram do estudo 40 profissionais militares da área de enfermagem. Foram identificados os seguintes fatores de risco para a HAS na população estudada: uso de contraceptivos hormonais (8,0%, tabagismo (7,0%, etilismo (2,0%, sedentarismo (21,0%, estresse (25,0%, consumo excessivo de sal (11,0%, obesidade (8,0% e dieta hipercalórica e hiperprotéica (18,0%.  A classificação da pressão arterial dos sujeitos revelou que 70,0% demonstraram valores pressóricos considerados normais ou ótimo, 12,5% valores considerados limítrofes e 17,5% comprovaram HAS. Conclusão: O estudo denota a necessidade de mudanças no estilo de vida dos profissionais, pois os fatores de risco associados aos níveis pressóricos podem contribuir para o aparecimento de HAS na população estudada. Descritores: Pressão arterial, hipertensão, enfermagem, enfermagem militar.

  9. Association Patterns of Endothelial Nitric Oxide Synthase Gene (NOS3) Variant Glu298Asp with Blood Pressure and Serum Lipid Levels in Subjects with Coronary Artery Disease from Pakistan.

    Science.gov (United States)

    Shahid, Saleem Ullah; Rehman, Abdul

    2017-07-01

    Nitric oxide is an important antiatherosclerotic agent. The main determinant of nitric oxide levels is enzyme nitric oxide synthase encoded by the NOS3 gene, the common variants in this gene may be responsible for variations in plasma enzyme levels. The association of NOS3 variants with coronary artery disease (CAD) varies in different ethnicities. The current study aimed to determine the association of NOS3 Glu298Asp (rs1799983) with CAD and blood lipid levels in Pakistani subjects. Six hundred thirty-six samples (412 cases, 224 controls) were genotyped by TaqMan allelic discrimination assay and serum total cholesterol, and High Density Lipoprotein cholesterol (HDL-C)/Low Density Lipoprotein cholesterol (LDL-C) and triglycerides were measured. The genotype frequency was Glu/Glu = 64.6%, Glu/Asp = 30.1%, and Asp/Asp = 5.3% in cases, and Glu/Glu = 68.8%, Glu/Asp = 26.7%, and Asp/Asp = 4.5% in controls. The Asp298 (T) frequency was not significantly higher in cases than controls (20.4% vs 17.9%, P = 0.28) and risk allele was not associated with CAD (OR 1.15 (0.86-1.54), P = 0.33) and the tested lipid traits but had a strong association with blood pressure (for systolic and diastolic P = 1.9×10(--56) and 4×10(--40) , respectively). In conclusion, although Glu298Asp did not show association with CAD and lipid profile in the studied cohort, it may exert its effect through blood pressure; however, the mechanism of this effect needs to be explored in the future. © 2017 John Wiley & Sons Ltd/University College London.

  10. Brachial Arterial Pressure Monitoring during Cardiac Surgery Rarely Causes Complications.

    Science.gov (United States)

    Singh, Asha; Bahadorani, Bobby; Wakefield, Brett J; Makarova, Natalya; Kumar, Priya A; Tong, Michael Zhen-Yu; Sessler, Daniel I; Duncan, Andra E

    2017-06-01

    Brachial arterial catheters better estimate aortic pressure than radial arterial catheters but are used infrequently because complications in a major artery without collateral flow are potentially serious. However, the extent to which brachial artery cannulation promotes complications remains unknown. The authors thus evaluated a large cohort of cardiac surgical patients to estimate the incidence of related serious complications. The institutional Society of Thoracic Surgeons Adult Cardiac Surgery Database and Perioperative Health Documentation System Registry of the Cleveland Clinic were used to identify patients who had brachial artery cannulation between 2007 and 2015. Complications within 6 months after surgery were identified by International Classification of Diseases, Ninth Revision diagnostic and procedural codes, Current Procedural Terminology procedure codes, and Society of Thoracic Surgeons variables. The authors reviewed electronic medical records to confirm that putative complications were related plausibly to brachial arterial catheterization. Complications were categorized as (1) vascular, (2) peripheral nerve injury, or (3) infection. The authors evaluated associations between brachial arterial complications and patient comorbidities and between complications and in-hospital mortality and duration of hospitalization. Among 21,597 qualifying patients, 777 had vascular or nerve injuries or local infections, but only 41 (incidence 0.19% [95% CI, 0.14 to 0.26%]) were potentially consequent to brachial arterial cannulation. Vascular complications occurred in 33 patients (0.15% [0.10 to 0.23%]). Definitely or possibly related infection occurred in 8 (0.04% [0.02 to 0.08%]) patients. There were no plausibly related neurologic complications. Peripheral arterial disease was associated with increased risk of complications. Brachial catheter complications were associated with prolonged hospitalization and in-hospital mortality. Brachial artery cannulation for

  11. 不同病因的肺动脉高压患者肺动脉压力水平研究%Comparison of Pulmonary Artery Pressure Levels in Patients with Pulmonary Hypertension of Different Causes

    Institute of Scientific and Technical Information of China (English)

    郭璐; 刘跃建; 解郑良; 周仲伟; 杨阳; 陈庆; 邹俊

    2013-01-01

    Objective To analyze and compare the levels of pulmonary artery pressure due to different causes in patients with pulmonary hypertension ( PH ) . Methods The data of 2 240 patients diagnosed with PH were retrospectively analyzed from outpatient department, emergency center and inpatient department of Sichuan provincial people's hospital from January 2006 to December 2010. The levels of pulmonary artery systolic pressure ( PASP ) were analyzed and compared for these patients with different causes. Results The proportion of mild, moderate and severe degree of PASP among the 2 240 patients was 43. 79% ( 981/2 240 ), 37. 41% ( 838/2 240 ) and 18. 80% ( 421/2 240 ) respectively. The level of mean PASP in patients with PH due to pulmonary arterial hypertension, left heart disease, chronic lung disease and/or hypoxia, chronic thromboembolic pulmonary hypertension and miscellaneous factors were respectively ( 60 ± 19 ) mm Hg, ( 52 ± 17 ) mm Hg, (50 ± 13 ) mm Hg, ( 61 ± 13 ) mm Hg and ( 56 ± 14 ) mm Hg, with a statistically significant difference by analysis of variance ( P < 0. 05 ) . The top 3 subtypes of PH which possessed the highest level of PASP were persistent pulmonary hypertension of the newborn being ( 97 ± 6 ) mm Hg, pulmonary hypertension due to congenital heart diseases being ( 72 ±28 ) mm Hg, and idiopathic pulmonary arterial hypertension being ( 67 ± 14 ) mm Hg respectively, with significant difference as compared with other subtypes ( P <0. 05 ) . And the subtypes with lowest level of PASP were PH due to portal hypertension and sleep - disordered breathing, being respectively ( 35 ± 15 ) mm Hg and ( 35 ± 16 ) mm Hg, with significant difference as compared with other subtypes ( P <0. 05 ). Conclusion The degree of pulmonary artery pressure is generally mild to moderate in patients with pulmonary hypertension. The highest -leveled subtypes of PH are persistent pulmonary hypertension of the newborn, pulmonary hypertension due to congenital heart

  12. Peripheral arterial blood pressure versus central crterial blood pressure monitoring in critically ill patients after Cardio-pulmonary Bypass.

    Science.gov (United States)

    Ahmad, Rana Altaf; Ahmad, Suhail; Naveed, Anjum; Baig, Mirza Ahmad Raza

    2017-01-01

    To determine the accuracy of peripheral (radial) arterial access as compared to central (femoral) arterial access for measurement of invasive blood pressure (IBP) in critically ill patients after cardiopulmonary bypass. Sixty patients (60) who required high inotropic/vasopressor support on weaning from cardio-pulmonary bypass and weaned off in 2(nd) attempt were included in this study. The duration of this study was from June 2015 to August 2016. Radial and femoral arterial access was achieved in all patients for simultaneous measurement of blood pressure. Arterial pressures were noted after 5, 15 and 30 minutes of weaning from cardiopulmonary bypass for both radial and femoral artery simultaneously. Mean age of study patients was 56.48±11.17 years. 85% patients were male. There was significant difference in systolic blood pressure, diastolic blood pressure and mean arterial pressures between the radial artery and femoral artery cannulation. Mean arterial pressures were significantly high in femoral artery as compared to the radial artery. The mean arterial pressures after five minutes of weaning using central access were 76.28±10.21 mmHg versus 64.15±6.76 mmHg in peripheral arterial access (p-value arterial pressures after 15 minutes of weaning from cardiopulmonary bypass 78.70±10.12 mmHg in central access versus 72.03±6.76 mmHg using peripheral arterial access (p-value arterial pressures were less marked as compared to the previous differences after 30 minutes of weaning from cardiopulmonary bypass as compared to the earlier readings (p-value 0.001). Peripheral arterial pressures are unreliable in critically ill patients after cardiopulmonary bypass receiving high dose of inotropic drugs. Central arterial access should be used in these patients to get accurate estimates of patients' blood pressure in early periods after cardiopulmonary bypass.

  13. Magnetic sensor for arterial distension and blood pressure monitoring.

    Science.gov (United States)

    Ruhhammer, Johannes; Herbstritt, Tamara; Ruh, Dominic; Foerster, Katharina; Heilmann, Claudia; Beyersdorf, Friedhelm; Goldschmidtboeing, Frank; Seifert, Andreas; Woias, Peter

    2014-12-01

    A novel sensor for measuring arterial distension, pulse and pressure waveform is developed and evaluated. The system consists of a magnetic sensor which is applied and fixed to arterial vessels without any blood vessel constriction, hence avoiding stenosis. The measurement principle could be validated by in vitro experiments on silicone tubes, and by in vivo experiments in an animal model, thereby indicating the non-linear viscoelastic characteristics of real blood vessels. The sensor is capable to provide absolute measurements of the dynamically varying arterial diameter. By calibrating the sensor, a long-term monitoring system for continuously measuring blood pressure and other cardiovascular parameters could be developed based on the method described. This will improve diagnostics for high risk patients and enable a better, specific treatment.

  14. The Relation Between Aortic Pulse Pressure and Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Ali Metin Esen

    2011-08-01

    Full Text Available Objective: Pulse pressure (PP is a significant marker of cardiovascular morbidity.We investigated the relation between aortic PP and the presence and extent of coronary artery disease (CAD in patients undergoing diagnostic coronary angiography (CAG.Patients and Method: The study group consisted of 550 patients (363 men, 187 women.We evaluated patients in two different groups, PP < 60 mmHg and ≥ 60 mmHg.Results: In univariate analysis gender and presence of hyperlipidemia showed no statistically significant differences between both groups. However, the ratio of patients having diabetes mellitus, hypertension or smoking were significantly higher in ≥ 60 mmHg PP group. The mean age was 55.2 ±11.9 in < 60 mmHg PP group and 61.3±9.3 in the other group (p<0.01. Although systolic blood pressure level was higher in ≥ 60 mmHg PP group (160.4±21.1 vs. 126.4±13.5, p< 0.001, diastolic blood pressure level showed no significant differences between both groups (78.3±13.5 vs. 80.3±10.2, p= 0.32. In the <60 mmHg PP group, the ratio of normal CAG was significantly higher, and also, the critically CAD rate was lower than the other group. In multivariate analysis, smoking [odds ratios (OR 2.344, 95% confidence intervals (CI, 1.416-3.879], male gender (OR 5.858, 95% CI, 3.425-10.019 and PP ≥60 mmHg (OR 25.788, 95% CI, 14.001-47.498 were evaluated as an independent indicators of CAD.Conclusions: In our study, we demonstrate that, aortic PP ≥60 mmHg is related to the risk of critically CAD as an independent factor.

  15. [Impact of periodontal disease on arterial pressure in diabetic mice].

    Science.gov (United States)

    Blasco-Baque, V; Kémoun, P; Loubieres, P; Roumieux, M; Heymes, C; Serino, M; Sixou, M; Burcelin, R

    2012-06-01

    Diabetes-driven cardiovascular diseases represent a high challenge for developed countries. Periodontal disease is strictly linked to the aforementioned diseases, due to its Gram negative-driven inflammation. Thus, we investigated the effects of periodontal disease on arterial pressure during the development of diabetes in mice. To this aim, C57BL/6 female mice were colonized with pathogens of periodontal tissue (Porphyromonas gingivalis, Prevotella intermedia and Fusobacterium nucleatum) for 1month, whereas another group of mice did not undergo the colonization. Subsequently, all mice were fed a high-fat carbohydrate-free diet for 3months. Then, arterial pressure was measured in vivo and a tomodensitometric analysis of mandibles was realized as well. Our results show increased mandibular bone-loss induced by colonization with periopathogens. In addition, periodontal infection augmented glucose-intolerance and systolic and diastolic arterial pressure, parameters already known to be affected by a fat-diet. In conclusion, we show here that periodontal disease amplifies metabolic troubles and deregulates arterial pressure, emerging as a new axis of metabolic investigation.

  16. [THE REMOTE MONITORING OF ARTERIAL PRESSURE AND RATE OF HEARTBEATS].

    Science.gov (United States)

    Shalkovskii, A G; Kuptsov, S M; Berseneva, E A

    2015-01-01

    The article considers issues of necessity of development and implementation of remote monitoring of arterial blood pressure and rate of heartbeats as a mean of enhancing quality of medical care of patients. The main characteristics of development of specialized automated system as an integral component of the project is considered too.

  17. Chronic antihypertensive treatment improves pulse pressure but not large artery mechanics in a mouse model of congenital vascular stiffness

    Science.gov (United States)

    Halabi, Carmen M.; Broekelmann, Thomas J.; Knutsen, Russell H.; Ye, Li; Mecham, Robert P.

    2015-01-01

    Increased arterial stiffness is a common characteristic of humans with Williams-Beuren syndrome and mouse models of elastin insufficiency. Arterial stiffness is associated with multiple negative cardiovascular outcomes, including myocardial infarction, stroke, and sudden death. Therefore, identifying therapeutic interventions that improve arterial stiffness in response to changes in elastin levels is of vital importance. The goal of this study was to determine the effect of chronic pharmacologic therapy with different classes of antihypertensive medications on arterial stiffness in elastin insufficiency. Elastin-insufficient mice 4–6 wk of age and wild-type littermates were subcutaneously implanted with osmotic micropumps delivering a continuous dose of one of the following: vehicle, losartan, nicardipine, or propranolol for 8 wk. At the end of treatment period, arterial blood pressure and large artery compliance and remodeling were assessed. Our results show that losartan and nicardipine treatment lowered blood pressure and pulse pressure in elastin-insufficient mice. Elastin and collagen content of abdominal aortas as well as ascending aorta and carotid artery biomechanics were not affected by any of the drug treatments in either genotype. By reducing pulse pressure and shifting the working pressure range of an artery to a more compliant region of the pressure-diameter curve, antihypertensive medications may mitigate the consequences of arterial stiffness, an effect that is drug class independent. These data emphasize the importance of early recognition and long-term management of hypertension in Williams-Beuren syndrome and elastin insufficiency. PMID:26232234

  18. Dynamic arterial elastance predicts mean arterial pressure decrease associated with decreasing norepinephrine dosage in septic shock.

    Science.gov (United States)

    Guinot, Pierre-Grégoire; Bernard, Eugénie; Levrard, Mélanie; Dupont, Hervé; Lorne, Emmanuel

    2015-01-19

    Gradual reduction of the dosage of norepinephrine (NE) in patients with septic shock is usually left to the physician's discretion. No hemodynamic indicator predictive of the possibility of decreasing the NE dosage is currently available at the bedside. The respiratory pulse pressure variation/respiratory stroke volume variation (dynamic arterial elastance (Eadyn)) ratio has been proposed as an indicator of vascular tone. The purpose of this study was to determine whether Eadyn can be used to predict the decrease in arterial pressure when decreasing the NE dosage in resuscitated sepsis patients. A prospective study was carried out in a university hospital intensive care unit. All consecutive patients with septic shock monitored by PICCO2 for whom the intensive care physician planned to decrease the NE dosage were enrolled. Measurements of hemodynamic and PICCO2 variables were obtained before/after decreasing the NE dosage. Responders were defined by a >15% decrease in mean arterial pressure (MAP). In total, 35 patients were included. MAP decreased by >15% after decreasing the NE dosage in 37% of patients (n = 13). Clinical characteristics appeared to be similar between responders and nonresponders. Eadyn was lower in responders than in nonresponders (0.75 (0.69 to 0.85) versus 1 (0. 83 to 1.22), P decrease in arterial pressure, with an area under the receiver-operating characteristic curve of 0.87 (95% confidence interval (95% CI): 0.72 to 0.96; P decrease in arterial pressure in response to NE dose reduction. Eadyn may constitute an easy-to-use functional approach to arterial-tone assessment, which may be helpful to identify patients likely to benefit from NE dose reduction.

  19. Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study

    OpenAIRE

    Mignini, Mariano Alejandro; Piacentini, Enrique; Dubin,Arnaldo

    2006-01-01

    Introduction Invasive arterial blood pressure monitoring is a common practice in intensive care units (ICUs). Accuracy of invasive blood pressure monitoring is crucial in evaluating the cardiocirculatory system and adjusting drug therapy for hemodynamic support. However, the best site for catheter insertion is controversial. Lack of definitive information in critically ill patients makes it difficult to establish guidelines for daily practice in intensive care. We hypothesize that peripheral ...

  20. [Arterial pressure curve and fluid status].

    Science.gov (United States)

    Pestel, G; Fukui, K

    2009-04-01

    Fluid optimization is a major contributor to improved outcome in patients. Unfortunately, anesthesiologists are often in doubt whether an additional fluid bolus will improve the hemodynamics of the patient or not as excess fluid may even jeopardize the condition. This article discusses physiological concepts of liberal versus restrictive fluid management followed by a discussion on the respective capabilities of various monitors to predict fluid responsiveness. The parameter difference in pulse pressure (dPP), derived from heart-lung interaction in mechanically ventilated patients is discussed in detail. The dPP cutoff value of 13% to predict fluid responsiveness is presented together with several assessment techniques of dPP. Finally, confounding variables on dPP measurements, such as ventilation parameters, pneumoperitoneum and use of norepinephrine are also mentioned.

  1. Resistance artery creatine kinase mRNA and blood pressure in humans.

    Science.gov (United States)

    Karamat, Fares A; Oudman, Inge; Ris-Stalpers, Carrie; Afink, Gijs B; Keijser, Remco; Clark, Joseph F; van Montfrans, Gert A; Brewster, Lizzy M

    2014-01-01

    Hypertension remains the main risk factor for cardiovascular death. Environmental and biological factors are known to contribute to the condition, and circulating creatine kinase was reported to be the main predictor of blood pressure in the general population. This was proposed to be because of high resistance artery creatine kinase-BB rapidly regenerating ATP for vascular contractility. Therefore, we assessed whether creatine kinase isoenzyme mRNA levels in human resistance arteries are associated with blood pressure. We isolated resistance-sized arteries from omental fat donated by consecutive women undergoing uterine fibroid surgery. Blood pressure was measured in the sitting position. Vessels of 13 women were included, 6 normotensive and 7 hypertensive, mean age 42.9 years (SE, 1.6) and mean systolic/diastolic blood pressure, 144.8 (8.0)/86.5 (4.3) mm Hg. Arteriolar creatine kinase isoenzyme mRNA was assessed using quantitative real-time polymerase chain reaction. Normalized creatine kinase B mRNA copy numbers, ranging from 5.2 to 24.4 (mean, 15.0; SE, 1.9), showed a near-perfect correlation with diastolic blood pressure (correlation coefficient, 0.9; 95% confidence interval, 0.6-1.0) and were well correlated with systolic blood pressure, with a 90% relative increase in resistance artery creatine kinase B mRNA in hypertensives compared with normotensives, normalized copy numbers were, respectively, 19.3 (SE, 2.0) versus 10.1 (SE, 2.1), P=0.0045. To our knowledge, this is the first direct evidence suggesting that resistance artery creatine kinase mRNA expression levels concur with blood pressure levels, almost doubling with hypertension. These findings add to the evidence that creatine kinase might be involved in the vasculature's pressor responses.

  2. Increasing arterial blood pressure with norepinephrine does not improve microcirculatory blood flow: a prospective study

    NARCIS (Netherlands)

    A. Dubin; M.O. Pozo; C.A. Casabella; F.,Jr Pálizas; G. Murias; M.C. Moseinco; V.S. Kanoore Edul; F. Pálizas; E. Estenssoro; C. Ince

    2009-01-01

    Introduction Our goal was to assess the effects of titration of a norepinephrine infusion to increasing levels of mean arterial pressure (MAP) on sublingual microcirculation. Methods Twenty septic shock patients were prospectively studied in two teaching intensive care units. The patients were mecha

  3. Mini invasive hemodynamic monitoring: from arterial pressure to cardiac output

    OpenAIRE

    Della Rocca, Giorgio; Cecconi, Maurizio; Costa, Maria Gabriella

    2008-01-01

    To evaluate the Cardiac Output (CO) the standard invasive pulmonary artery catheter (PAC) is considered today the gold standard. The major criticism to the PAC is that its level of invasiveness is not supported by an improvement in patient's outcome. The interest to lesser and lesser invasive techniques is high. Therefore, the alternative techniques have been recently developed.Cardiac Output can be monitored continuously by different devices that analyze the arterial waveform to track change...

  4. Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational study

    National Research Council Canada - National Science Library

    Romagnoli, Stefano; Ricci, Zaccaria; Quattrone, Diego; Tofani, Lorenzo; Tujjar, Omar; Villa, Gianluca; Romano, Salvatore M; De Gaudio, A Raffaele

    2014-01-01

    Critically ill patients and patients undergoing high-risk and major surgery, are instrumented with intra-arterial catheters and invasive blood pressure is considered the "gold standard" for arterial pressure monitoring...

  5. Systolic Pressure in Different Percents of Stenosis at Major Arteries

    CERN Document Server

    Mirzaee, Mohammad Reza; Firoozabadi, Bahar; Dandaneband, Meitham

    2016-01-01

    - Modeling Human cardiovascular system is always an important issue. One of the most effective methods is using lumped model to reach to a complete model of human cardiovascular system. Such modeling with advanced considerations is used in this paper. Some of these considerations are as follow: Exact simulating of ventricles as pressure suppliers, peristaltic motion of descending arteries as additional suppliers, and dividing each vessel into more than one compartment to reach more accurate answers. Finally a circuit with more than 150 RLC segments and different elements is made. Then the verification of our complex circuit is done and at the end, obstruction as an important abnormality is investigated. For this aim different percents of obstruction in vital arteries are considered and the results are brought as different graphs at the end. According to physiological texts the citation of our simulation and its results are obvious. To earn productive information about arteries characteristics a 36-vessels mod...

  6. [Value of dynamic arterial elastance in the predication of arterial pressure response to volume loading in shock patients].

    Science.gov (United States)

    Gong, Mao-lei; Liu, Da-wei; Wang, Xiao-ting; Chen, Xiu-kai

    2013-05-07

    To explore the value of dynamic arterial elastance (Eadyn) in the predication of arterial pressure response to volume loading in shock patients. A total of 32 patients with pulse indicator continuous cardiac output (PICCO) monitoring at our intensive care unit from January 2011 to December 2012 were retrospectively studied. The decision of fluid replacement was based upon the presence of shock (mean arterial pressure (MAP) ≤ 65 mm Hg, systolic arterial pressure arterial pressure response to volume loading. Significantly different between MAP responders and MAP nonresponders, baseline Eadyn was an effective predictor of MAP increase after volume loading. The area under the ROC curve was 0.95 for the prediction of volume loading on MAP for Eadyn at baseline (P 0.85 predicted a MAP increase after volume administration with a sensitivity of 89.5% and a specificity of 92.3%. Baseline Eadyn may predict accurately arterial pressure response in MAP to volume loading in shock patients.

  7. The giraffe kidney tolerates high arterial blood pressure by high renal interstitial pressure and low glomerular filtration rate

    DEFF Research Database (Denmark)

    Damkjær, Mads; Wang, T; Brøndum, E

    2015-01-01

    BACKGROUND: The tallest animal on earth, the giraffe (Giraffa camelopardalis) is endowed with a mean arterial blood pressure (MAP) twice that of other mammals. The kidneys reside at heart level and show no sign of hypertension-related damage. We hypothesized that a species-specific evolutionary...... on body mass. A strong renal capsule supports a RIHP, which is >10-fold that of other mammals effectively reducing the net filtration pressure and protecting against the high MAP....... renal plasma flow (ERPF). Renal interstitial hydrostatic pressure (RIHP) was assessed by inserting a needle into the medullary parenchyma. Doppler ultrasound measurements provided renal artery resistive index (RI). Hormone concentrations as well as biomechanical, structural and histological...

  8. Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: comparison with invasively assessed radial arterial pressure.

    Science.gov (United States)

    Meidert, A S; Huber, W; Müller, J N; Schöfthaler, M; Hapfelmeier, A; Langwieser, N; Wagner, J Y; Eyer, F; Schmid, R M; Saugel, B

    2014-03-01

    Radial artery applanation tonometry technology can be used for continuous non-invasive measurement of arterial pressure (AP). The purpose of this study was to evaluate this AP monitoring technology in intensive care unit (ICU) patients in comparison with invasive AP monitoring using a radial arterial catheter. In 24 ICU patients (German university hospital), AP values were simultaneously recorded on a beat-to-beat basis using radial artery applanation tonometry (T-Line system; Tensys Medical, San Diego, CA, USA) and a radial arterial catheter (contralateral arm). The primary endpoint of the study was to investigate the accuracy and precision of the non-invasively assessed AP measurements with the Bland-Altman method based on averaged 10 beat AP epochs (n=2993 10 beat epochs). For mean AP (MAP), systolic AP (SAP), and diastolic AP (DAP), we observed a bias (±standard deviation of the bias; 95% limits of agreement; percentage error) of +2 mm Hg (±6; -11 to +15 mm Hg; 15%), -3 mm Hg (±15; -33 to +27 mm Hg; 23%), and +5 mm Hg (±7; -9 to +19 mm Hg; 22%), respectively. In ICU patients, MAP and DAP measurements obtained using radial artery applanation tonometry show clinically acceptable agreement with invasive AP determination with a radial arterial catheter. While the radial artery applanation tonometry technology also allows SAP measurements with high accuracy, its precision for SAP measurements needs to be further improved.

  9. 高血压与颈动脉粥样硬化相关性的研究进展%Relationship between level of blood pressure and intima-media thickness of carotid artery

    Institute of Scientific and Technical Information of China (English)

    陈齐军; 刘彬; 杨潘杰; 曾文真

    2014-01-01

    The primary hypertension (PH) is a global multiple diseases, initially the main performance are blood pressure, then accompanied by multiple target organ damage and metabolic disorders of systemic disease. PH is an independent risk factor for atherosclerosis, which can lead atherosclerosis of aorta, carotid, cerebral artery, coronary, renal artery, superior mesenteric artery and limbs artery, causing cerebral vascular accident, coronary atherosclerotic heart disease, chronic renal failure and other serious diseases. Carotid artery is relatively superficial, the lesions appear earlier, and the examinations are noninvasive, convenient and accurate. The change of carotid intima-media thickness and atheromatous plaque, may well reflect the influence of PH on systemic atherosclerosis, as well as the relationship between different blood pressure and atherosclerosis. Therefore, early recognition and accurate assessment on carotid artery disease of patients with PH, would have great significance on early prevention, efficacy evaluation and prognosis of the disease.%原发性高血压是一种全球性多发性疾病,起初是以血压升高为主要表现,继而伴有多个靶器官功能损害和代谢紊乱的全身性疾病。原发性高血压是动脉粥样硬化的独立危险因素,可导致主动脉、颈动脉、脑动脉、冠状动脉、肾动脉、肠系膜动脉及四肢动脉等的粥样硬化,从而引发脑血管意外、冠状动脉粥样硬化性心脏病、慢性肾功能不全等严重疾病。颈动脉较为表浅,病变出现较早,颈动脉内膜-中膜厚度的改变及粥样斑块情况可较好地反映原发性高血压对全身动脉粥样硬化的影响,以及不同血压水平与动脉粥样硬化发生的关系。因此,对原发性高血压患者颈动脉病变的早期识别和准确评价,对疾病的早期防治和疗效评估及预后有重大意义。

  10. Carotid artery disease and low cerebral perfusion pressure

    DEFF Research Database (Denmark)

    Schroeder, T; Utzon, N P; Aabech, J

    1990-01-01

    Direct internal carotid artery blood pressure measurements in patients undergoing carotid endarterectomy identified 49 patients, among 239 consecutive cases (21%), who had a reduction in perfusion pressure of 20% or more. The clinical history, objective findings and angiographic data were compared...... with those of a control group of a further 49 patients selected from the remaining patients operated on over the same period. The two groups were compared for short- and long-term outcome of surgery. We were unable to delineate a symptomatic neurological profile that identified patients with low perfusion...... pressures. Surgery in patients with low perfusion pressures seemed to be associated with an increased complication rate (12% versus 4%), although this was not statistically significant. Definite postoperative improvements in persisting neurological deficits were observed only in one patient. Long...

  11. Hyperoxia increases arterial oxygen pressure during exercise in type 2 diabetes patients: a feasibility study.

    Science.gov (United States)

    Rozenberg, Robert; Mankowski, Robert T; van Loon, Luc J C; Langendonk, Janneke G; Sijbrands, Eric J G; van den Meiracker, Anton H; Stam, Henk J; Praet, Stephan F E

    2016-01-08

    The study investigated the feasibility and potential outcome measures during acute hyperoxia in type 2 diabetes patients (DM2). Eleven DM2 patients (7 men and 4 women) were included in the study. The patients cycled (30 min at 20% Wmax) whilst breathing three different supplemental oxygen flows (SOF, 5, 10, 15 L min(-1)). During hyperoxic exercise, arterial blood gases and intra-arterial blood pressure measurements were obtained. Arterial pO2 levels increased significantly (ANOVA, p Heart rate (HR) and pH increased significantly after terminating administration of hyperoxic air. An SOF of 15 L min(-1) appears to be more effective than 5 or 10 L min(-1). Moreover, HR, blood pressure, blood lactate and pH are not recommended as primary outcome measures.

  12. Integration of a capacitive pressure sensing system into the outer catheter wall for coronary artery FFR measurements

    Science.gov (United States)

    Stam, Frank; Kuisma, Heikki; Gao, Feng; Saarilahti, Jaakko; Gomes Martins, David; Kärkkäinen, Anu; Marrinan, Brendan; Pintal, Sebastian

    2017-05-01

    The deadliest disease in the world is coronary artery disease (CAD), which is related to a narrowing (stenosis) of blood vessels due to fatty deposits, plaque, on the arterial walls. The level of stenosis in the coronary arteries can be assessed by Fractional Flow Reserve (FFR) measurements. This involves determining the ratio between the maximum achievable blood flow in a diseased coronary artery and the theoretical maximum flow in a normal coronary artery. The blood flow is represented by a pressure drop, thus a pressure wire or pressure sensor integrated in a catheter can be used to calculate the ratio between the coronary pressure distal to the stenosis and the normal coronary pressure. A 2 Fr (0.67mm) outer diameter catheter was used, which required a high level of microelectronics miniaturisation to fit a pressure sensing system into the outer wall. The catheter has an eccentric guidewire lumen with a diameter of 0.43mm, which implies that the thickest catheter wall section provides less than 210 microns height for flex assembly integration consisting of two dies, a capacitive MEMS pressure sensor and an ASIC. In order to achieve this a very thin circuit flex was used, and the two chips were thinned down to 75 microns and flip chip mounted face down on the flex. Many challenges were involved in obtaining a flex layout that could wrap into a small tube without getting the dies damaged, while still maintaining enough flexibility for the catheter to navigate the arterial system.

  13. Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis.

    Science.gov (United States)

    Kim, Sang-Hyun; Lilot, Marc; Sidhu, Kulraj S; Rinehart, Joseph; Yu, Zhaoxia; Canales, Cecilia; Cannesson, Maxime

    2014-05-01

    Continuous noninvasive arterial pressure monitoring devices are available for bedside use, but the accuracy and precision of these devices have not been evaluated in a systematic review and meta-analysis. The authors performed a systematic review and meta-analysis of studies comparing continuous noninvasive arterial pressure monitoring with invasive arterial pressure monitoring. Random-effects pooled bias and SD of bias for systolic arterial pressure, diastolic arterial pressure, and mean arterial pressure were calculated. Continuous noninvasive arterial pressure monitoring was considered acceptable if pooled estimates of bias and SD were not greater than 5 and 8 mmHg, respectively, as recommended by the Association for the Advancement of Medical Instrumentation. Twenty-eight studies (919 patients) were included. The overall random-effect pooled bias and SD were -1.6 ± 12.2 mmHg (95% limits of agreement -25.5 to 22.2 mmHg) for systolic arterial pressure, 5.3 ± 8.3 mmHg (-11.0 to 21.6 mmHg) for diastolic arterial pressure, and 3.2 ± 8.4 mmHg (-13.4 to 19.7 mmHg) for mean arterial pressure. In 14 studies focusing on currently commercially available devices, bias and SD were -1.8 ± 12.4 mmHg (-26.2 to 22.5 mmHg) for systolic arterial pressure, 6.0 ± 8.6 mmHg (-10.9 to 22.9 mmHg) for diastolic arterial pressure, and 3.9 ± 8.7 mmHg (-13.1 to 21.0 mmHg) for mean arterial pressure. The results from this meta-analysis found that inaccuracy and imprecision of continuous noninvasive arterial pressure monitoring devices are larger than what was defined as acceptable. This may have implications for clinical situations where continuous noninvasive arterial pressure is being used for patient care decisions.

  14. Acute nitric oxide synthase inhibition and endothelin-1-dependent arterial pressure elevation

    Directory of Open Access Journals (Sweden)

    Robert eRapoport

    2014-04-01

    Full Text Available Key evidence that endogenous nitric oxide (NO inhibits the continuous, endothelin (ET-1-mediated drive to elevate arterial pressure includes demonstrations that ET-1 mediates a significant component of the pressure elevated by acute exposure to NO synthase (NOS inhibitors. This review examines the characteristics of this pressure elevation in order to elucidate potential mechanisms associated with the negative regulation of ET-1 by NO and, thereby, provide potential insight into the vascular pathophysiology underlying NO dysregulation. We surmise that the magnitude of the ET-1-dependent component of the NOS inhibitor-elevated pressure is 1 independent of underlying arterial pressure and other pressor pathways activated by the NOS inhibitors and 2 dependent on relatively higher NOS inhibitor dose, release of stored and de novo synthesized ET-1, and ETA receptor-mediated increased vascular resistance. Major implications of these conclusions include: 1 the marked variation of the ET-1-dependent component, i.e., from 0-100% of the pressure elevation, reflects the NO-ET-1 regulatory pathway. Thus, NOS inhibitor-mediated, ET-1-dependent pressure elevation in vascular pathophysiologies is an indicator of the level of compromised/enhanced function of this pathway; 2 NO is a more potent inhibitor of ET-1-mediated elevated arterial pressure than other pressor pathways, due in part to inhibition of intravascular pressure-independent release of ET-1. Thus, the ET-1-dependent component of pressure elevation in vascular pathophysiologies associated with NO dysregulation is of greater magnitude at higher levels of compromised NO.

  15. Blood pressure control in patients with arterial hypertension in Slovenia

    Directory of Open Access Journals (Sweden)

    Marija Petek-Šter

    2007-06-01

    Full Text Available Background: Blood pressure control is sub-optimal all over the world. The aim of the study was to find out about the quality of the blood pressure control in Slovenia.Patients and method: Randomly selected general practitioners fulfilled a questionnaire for each of the 20 conse cutive attenders with arterial hypertension. We collected data for 980 patients with arterial hypertension, who attended their general practitioners in September 2006. Data about blood pressure control was taken from the medical record; we took into account the last two blood pressure measurements in the office before the visit in which we selected the study sample.Results: In the sample of 980 patients there were 47.4 % male and 52.6 % female, who were from 20 to 97 years old (average 62.3 years, SD 11.9 years. The target blood pressure was reached in 388 (40.1 % patients with hypertension. 927 (94.6 % patients were given an advice on non-pharmacological measures. In 986 (98.8 % patients antihypertensive drugs were prescribed. 668 (68.2 % patients took a combined antihypertensive treatment. The most frequently prescribed drug classes were blockers of renin-angiotensine system in 843 (86.0 % patients, 225 (23.2 % patients took blockers of renin-angiotensine receptors. In 527 (53.8 % patients antihypertensive treatment was changed during the treatment. Physicians performed at least one measure to improve blood pressure control in 430 (74.3 % patients with uncontrolled hypertension; changes in drug treatment were made in 252 (43.5 % patients.Conclusions: More frequent advice on non-pharmacological measures, more intensive drug treatment and adaptation of treatment to patients lead to better blood pressure control.

  16. Relative contributions from the ventricle and arterial tree to arterial pressure and its amplification: an experimental study.

    Science.gov (United States)

    Gaddum, Nicholas; Alastruey, Jordi; Chowienczyk, Phil; Rutten, Marcel C M; Segers, Patrick; Schaeffter, Tobias

    2017-09-01

    Arterial pressure is an important diagnostic parameter for cardiovascular disease. However, relative contributions of individual ventricular and arterial parameters in generating and augmenting pressure are not understood. Using a novel experimental arterial model, our aim was to characterize individual parameter contributions to arterial pressure and its amplification. A piston-driven ventricle provided programmable stroke profiles into various silicone arterial trees and a bovine aorta. Inotropy was varied in the ventricle, and arterial parameters modulated included wall thickness, taper and diameter, the presence of bifurcation, and a native aorta (bovine) versus silicone. Wave reflection at bifurcations was measured and compared with theory, varying parent-to-child tube diameter ratios, and branch angles. Intravascular pressure-tip wires and ultrasonic flow probes measured pressure and flow. Increasing ventricular inotropy independently augmented pressure amplification from 17% to 61% between the lower and higher systolic gradient stroke profiles in the silicone arterial network and from 10% to 32% in the bovine aorta. Amplification increased with presence of a bifurcation, decreasing wall thickness and vessel taper. Pulse pressure increased with increasing wall thickness (stiffness) and taper angle and decreasing diameter. Theoretical predictions of wave transmission through bifurcations werre similar to measurements (correlation: 0.91, R(2) = 0.94) but underestimated wave reflection (correlation: 0.75, R(2) = 0.94), indicating energy losses during mechanical wave reflection. This study offers the first comprehensive investigation of contributors to hypertensive pressure and its propagation throughout the arterial tree. Importantly, ventricular inotropy plays a crucial role in the amplification of peripheral pressure wave, which offers opportunity for noninvasive assessment of ventricular health.NEW & NOTEWORTHY The present study distinguishes contributions

  17. Perinatal taurine exposure affects adult arterial pressure control

    Science.gov (United States)

    Roysommuti, Sanya; Wyss, J. Michael

    2012-01-01

    Taurine is an abundant free amino acid found in mammalian cells that contributes to many physiologic functions from that of a simple cell osmolyte to a programmer of adult health and disease. Taurine’s contribution extends from conception throughout life, but its most critical exposure period is during perinatal life. In adults, taurine supplementation prevents or alleviates cardiovascular disease and related complications. In contrast, low taurine consumption coincides with increased risk of cardiovascular disease, obesity and type II diabetes. This review focuses on the effects that altered perinatal taurine exposure has on long-term mechanisms that control adult arterial blood pressure and could thereby contribute to arterial hypertension through its ability to program these cardiovascular regulatory mechanisms very early in life. The modifications of these mechanisms can last a lifetime and transfer to the next generation, suggesting that epigenetic mechanisms underlie the changes. The ability of perinatal taurine exposure to influence arterial pressure control mechanisms and hypertension in adult life appears to involve the regulation of growth and development, the central and autonomic nervous system, the renin-angiotensin system, glucose-insulin interaction and changes to heart, blood vessels and kidney function. PMID:23070226

  18. Giant, Dissecting, High-Pressure Pulmonary Artery Aneurysm

    Science.gov (United States)

    Smalcelj, Anton; Brida, Vojtjeh; Samarzija, Miroslav; Matana, Ante; Margetic, Eduard; Drinkovic, Niksa

    2005-01-01

    We report the rare subchronic clinical course of a giant, dissecting pulmonary artery aneurysm in an oligosymptomatic middle-aged woman who had idiopathic pulmonary hypertension. Diagnosis was simple with the use of echocardiography and multislice computed tomography. Conversely, deciding on the treatment was difficult, because prominent surgeons declined to perform surgical repair of the aneurysm and recommended heart–lung transplantation. Therefore, we were forced to treat our patient medically. She survived for 1 year, including 8 months of treatment with sildenafil, and then died suddenly while awaiting transplantation. Our patient, who had a dissecting, high-pressure pulmonary artery aneurysm, had an unexpectedly stable and uneventful clinical course for 1 year, which, under more favorable circumstances, might have provided enough time for heart–lung transplantation to be performed. PMID:16429912

  19. Comparison of femoral and auricular arterial blood pressure monitoring in pigs.

    Science.gov (United States)

    Bass, Louise M E; Yu, Dao-Yi; Cullen, Len K

    2009-09-01

    To compare arterial blood pressure measurements obtained from the femoral and auricular arteries in anaesthetized pigs. Prospective experimental study. Fifteen female Large White pigs were used weighing 21.3 +/- 2.3 kg. The pigs were anaesthetized with tiletamine/zolazepam and xylazine administered intramuscularly, and anaesthesia maintained with isoflurane delivered in oxygen/nitrogen. Arterial oxygen partial pressures were maintained between 11.3 and 13.3 kPa and PaCO(2) between 4.6 and 6.0 kPa. Monitoring included electrocardiogram, capnography and invasive blood pressure. The auricular and femoral arteries were catheterized for continuous systolic (SAP), diastolic (DAP) and mean arterial pressure (MAP) measurements. Measurements were recorded every 15 minutes. Statistical analysis involved a Bland-Altman plot analysis. The mean difference +/- confidence intervals between the femoral and the auricular arterial diastolic, systolic and mean blood pressure measurements during hypotension were 2 +/- 7, 2 +/- 5 and 2 +/- 5 mmHg respectively. In conditions of normotension mean difference +/- confidence intervals, of femoral and auricular arterial blood pressure measurements of diastolic, systolic and mean blood pressure were 4 +/- 5, 3 +/- 7 and 4 +/- 4 mmHg respectively. In conditions of increased arterial blood pressure, mean difference +/- confidence intervals, of femoral and auricular arterial blood pressure measurements of diastolic, systolic and mean blood pressure were 4 +/- 5, 3 +/- 8 and 4 +/- 4 mmHg respectively. Auricular artery catheterization is easier and quicker to perform. Pressure measurements from the auricular artery compared well with the femoral artery. We found that auricular arterial blood pressures were similar to femoral arterial values under the conditions of this experiment. We did not test extremes of blood pressure or significant alterations in body temperature.

  20. A Neural Network for Estimation of Aortic Pressure from the Radial Artery Pressure Pulse

    Science.gov (United States)

    2001-10-25

    from periphery to artery: a model based study, American Journal of Physiology, 1998,274:43, pp H1386-92 [9] C. Chen, E. Nevo , B Fetics, P Pak, F, Yin, L...36. [10] B Fetics, E Nevo , C. Chen, D Kass, Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial

  1. Hemodynamics in arterial reconstructions of the lower limb. II. Blood pressure.

    Science.gov (United States)

    Dedichen, H

    1976-01-01

    In order to demonstrate common pressure gradients and peripheral arterial pressure in ileo-femoro-popliteal arteries before and after reconstruction for atherosclerosis, intra-operative pressure measurements were performed on 204 patients. Before reconstruction, the pressure differential was 44.3 mmHg in femoro-popliteal arteries and 29.0 mmHg in the iliac arteries. This was reduced to 8.4 and 4.1 mmHg by the reconstructions. In patients with femoro-popliteal disease, the pressure gradient was higher when gangrena or rest pain were present than when claudication was the principal symptom. When the iliac arteries were mainly involved, no such difference was seen. Postoperative gradients were slightly higher in arteries subjected to primary failure than in vessels remaining patent. The blood flow increase from intra-arterial papaverine injections accentuated existing pressure gradients and frequently disclosed gradients not manifest at basal flow rates.

  2. Relationship of daily arterial blood pressure monitoring readings and arterial stiffness profile in male patients with chronic obstructive pulmonary disease combined with arterial hypertension

    Directory of Open Access Journals (Sweden)

    Karoli N.A.

    2013-06-01

    Full Text Available The aim of the study was to determine correlation between arterial blood pressure daily rhythm and daily profile of arterial stiffness in male patients with chronic obstructive pulmonary disease (COPD and arterial hypertension. Materials et methods: Prospective investigation comprised 45 male patients with COPD and arterial hypertension. Individuals of 40 years younger and 80 years elder, patients with diabetes, stroke, angina pectoris, or heart infarction, vascular diseases, and exacerbation of chronic disease, bronchial and pulmonary diseases of other etiology were excluded from the analyses. Comparison group included 47 patients with essential arterial hypertension and without chronic respiratory diseases closely similar on general parameters with patients from main clinical series. Twenty-four-hour arterial blood pressure monitoring (ABPM and daily arterial stiffness monitoring were performed using BPLab® MnSDP-2 apparatus (Petr Telegin, Russian Federation. Results: Patients with COPD combined with arterial hypertension with raised arterial stiffness measures prevail over individuals in essential hypertension group. There is pathological alteration of the ABPM circadian rhythm and raised «Pressure load» values in raised arterial stiffness group. Conclusion: We found ABPM raised parameters in patients with COPD and arterial hypertension. It confirms necessity of ABPM in daily arterial stiffness assessment in patients with COPD.

  3. Redox signaling via oxidative inactivation of PTEN modulates pressure-dependent myogenic tone in rat middle cerebral arteries.

    Directory of Open Access Journals (Sweden)

    Debebe Gebremedhin

    Full Text Available The present study examined the level of generation of reactive oxygen species (ROS and roles of inactivation of the phosphatase PTEN and the PI3K/Akt signaling pathway in response to an increase in intramural pressure-induced myogenic cerebral arterial constriction. Step increases in intraluminal pressure of cannulated cerebral arteries induced myogenic constriction and concomitant formation of superoxide (O2 (.- and its dismutation product hydrogen peroxide (H2O2 as determined by fluorescent HPLC analysis, microscopic analysis of intensity of dihydroethidium fluorescence and attenuation of pressure-induced myogenic constriction by pretreatment with the ROS scavenger 4,hydroxyl-2,2,6,6-tetramethylpiperidine1-oxyl (tempol or Mito-tempol or MitoQ in the presence or absence of PEG-catalase. An increase in intraluminal pressure induced oxidation of PTEN and activation of Akt. Pharmacological inhibition of endogenous PTEN activity potentiated pressure-dependent myogenic constriction and caused a reduction in NPo of a 238 pS arterial KCa channel current and an increase in [Ca(2+]i level in freshly isolated cerebral arterial muscle cells (CAMCs, responses that were attenuated by Inhibition of the PI3K/Akt pathway. These findings demonstrate an increase in intraluminal pressure induced increase in ROS production triggered redox-sensitive signaling mechanism emanating from the cross-talk between oxidative inactivation of PTEN and activation of the PI3K/Akt signaling pathway that involves in the regulation of pressure-dependent myogenic cerebral arterial constriction.

  4. Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure.

    Science.gov (United States)

    Zheng, Dingchang; Murray, Alan

    2011-05-01

    A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume distensibility were determined. With a 40 mmHg reduction in transmural pressure, arm pulse propagation time increased from 61 to 83 ms, PWV decreased from 12 to 8 m s(-1) and arterial distensibility increased from 0.102% to 0.232% per mmHg (all P pressures, arterial distensibility was significantly related to resting mean arterial pressure (MAP), diastolic blood pressure (DBP) and age, and for systolic blood pressure at 30 and 40 mmHg (all P pressure, arterial distensibility fell by 54% for a MAP increase from 75 to 105 mmHg, 57% for a DBP increase from 60 to 90 mmHg and 47% for an age increase from 20 to 70 years. These changes were more than double than those without cuff pressure. Our technique showed that systemic volume distensibility of the peripheral arm artery reduced with age, with a greater effect at higher external and lower transmural pressures.

  5. Arterial blood pressure and heart rate regulation in shock state.

    Science.gov (United States)

    DellaVolpe, Jeffrey D; Moore, Jason E; Pinsky, Michael R

    2015-10-01

    Circulatory shock is a complicated problem that carries a high risk of complications and mortality for critically ill patients. The heart rate and blood pressure targets to which a patient in shock should be resuscitated remain a challenge to intensivists. While the ideal blood pressure and heart rate in circulatory shock are still not definitive, recent studies have begun to refine these targets. A recent trial comparing a mean arterial pressure target of 80-85 mmHg with a target of 65-70 mmHg showed no difference in mortality, with a decreased need for renal replacement therapy in patients with pre-existing hypertension based on subgroup analysis. Regulation of heart rate was defined by a trial demonstrating that heart rate control in patients with severe sepsis on high-dose norepinephrine with esmolol titration did not result in additional adverse events. The ideal target blood pressure in the resuscitation of circulatory shock is variable and likely depends on prior blood pressure. Heart rate regulation with β-blockade appears to be safe in selected patients when accompanied by adequate resuscitation and monitoring.

  6. Arterial ammonia levels in the management of fulminant liver failure

    Directory of Open Access Journals (Sweden)

    Curry S

    2011-06-01

    Full Text Available Previous studies have suggested that an arterial ammonia level greater than 150 mmol/L is highly sensitive for predicting subsequent development of cerebral edema in patients with fulminant liver failure. We performed a prospective cohort study to confirm this relationship. We enrolled 22 consecutive patients who presented to our transplant hepatology service with grade 3-4 encephalopathy associated with fulminant liver failure. All patients underwent placement of an intraparenchymal ICP monitor, and every 12 hourly arterial ammonia levels. The prevalence of intracranial hypertension (IHTN in our population was 95% (21/22 patients, with 82 discrete episodes recorded. The sensitivity of arterial ammonia levels to predict the onset of IHTN was 62% (95% CI: 40.8 to 79.3 at a cut point of 150 mmol/L. Arterial ammonia levels preceding the first intracranial hypertension event were less than 150 mmol/L in 8 of 21 patients (39%. Fifty nine of 82 episodes of IHTN (73% occurred when arterial ammonia levels were less than 150 mmol/L. We conclude that the arterial ammonia level is not useful in making decisions regarding management related to cerebral edema in patients with fulminant liver failure. In fact, since almost all our study patients with grade III or IV encephalopathy secondary to fulminant liver failure went on to develop intracranial hypertension, our study supports the contention that all such patients might benefit from ICP monitoring regardless of arterial ammonia levels.

  7. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers...... by direct cooling or intra-arterial noradrenaline infusion caused a marked drop in FSP in the exposed fingers, but not in the non-exposed fingers of the same hand. The fact that the non-exposed fingers retained the normal (arm systolic) pressure level is taken to indicate that palmar arch blood pressure...... also remained normal. In the high vascular tone state, a large transmural pressure difference must apparently be established before the digital arteries are forced open. The lowered opening pressure constitutes a manifestation of the closure phenomenon of the digital arteries described in patients...

  8. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers...... by direct cooling or intra-arterial noradrenaline infusion caused a marked drop in FSP in the exposed fingers, but not in the non-exposed fingers of the same hand. The fact that the non-exposed fingers retained the normal (arm systolic) pressure level is taken to indicate that palmar arch blood pressure...... also remained normal. In the high vascular tone state, a large transmural pressure difference must apparently be established before the digital arteries are forced open. The lowered opening pressure constitutes a manifestation of the closure phenomenon of the digital arteries described in patients...

  9. Exploring Arterial Smooth Muscle Kv7 Potassium Channel Function using Patch Clamp Electrophysiology and Pressure Myography

    Science.gov (United States)

    Brueggemann, Lioubov I.; Mani, Bharath K.; Haick, Jennifer; Byron, Kenneth L.

    2012-01-01

    Contraction or relaxation of smooth muscle cells within the walls of resistance arteries determines the artery diameter and thereby controls flow of blood through the vessel and contributes to systemic blood pressure. The contraction process is regulated primarily by cytosolic calcium concentration ([Ca2+]cyt), which is in turn controlled by a variety of ion transporters and channels. Ion channels are common intermediates in signal transduction pathways activated by vasoactive hormones to effect vasoconstriction or vasodilation. And ion channels are often targeted by therapeutic agents either intentionally (e.g. calcium channel blockers used to induce vasodilation and lower blood pressure) or unintentionally (e.g. to induce unwanted cardiovascular side effects). Kv7 (KCNQ) voltage-activated potassium channels have recently been implicated as important physiological and therapeutic targets for regulation of smooth muscle contraction. To elucidate the specific roles of Kv7 channels in both physiological signal transduction and in the actions of therapeutic agents, we need to study how their activity is modulated at the cellular level as well as evaluate their contribution in the context of the intact artery. The rat mesenteric arteries provide a useful model system. The arteries can be easily dissected, cleaned of connective tissue, and used to prepare isolated arterial myocytes for patch clamp electrophysiology, or cannulated and pressurized for measurements of vasoconstrictor/vasodilator responses under relatively physiological conditions. Here we describe the methods used for both types of measurements and provide some examples of how the experimental design can be integrated to provide a clearer understanding of the roles of these ion channels in the regulation of vascular tone. PMID:23007713

  10. A new noninvasive device for continuous arterial blood pressure monitoring in the superficial temporal artery.

    Science.gov (United States)

    Chin, K Y; Panerai, R B

    2013-04-01

    Continuous recording of arterial blood pressure (ABP) has many applications in cardiovascular physiology, but existing alternatives rely on measurements performed in the fingers or radial artery. Peripheral recordings have significant differences from central ABP regarding the pattern of the waveform and corresponding systolic and diastolic values. To address the need for noninvasive measurements closer to the ascending aorta, a new device was constructed to measure ABP in the superficial temporal artery (STA) using photoplethysmography and the arterial volume clamping technique. The optoelectronic circuitry to generate the photoplethysmogram is contained in a specially designed probe placed over the STA and kept in place with a head frame. The prototype (STAbp) also includes original designs for the pneumatic, electronic, signal processing, control and display sub-systems. A self-calibration feature regularly updates the photoplethysmogram operating point to improve accuracy. The performance of the STAbp was compared against the Finapres in 19 healthy subjects. At rest, the bias (SDd) was -23.1 (15.05), -10.8 (13.83) and -12.4 (12.93) mmHg for systolic, mean and diastolic pressures respectively, without significant differences in drift between the two devices. The 99% bandwidth (SD) for the spectral distribution of ABP waveforms was 5.3 (1.46) Hz for STAbp and 6.8 (0.73) Hz for the Finapres (p < 0.01). Handgrip manoeuvre showed a very similar response to the Finapres, including the rapid return to baseline on release. The new STAbp device has considerable potential as a new tool for clinical and research applications where continuous recording of more central ABP is advantageous compared to peripheral alternatives.

  11. Level selection in leg amputation for arterial occlusive disease

    DEFF Research Database (Denmark)

    Holstein, P

    1982-01-01

    In 102 leg amputations for arterial occlusion including 84 below-knee (BK), 16 above-knee (AD) and 2 through-knee (TK) amputations, the amputation level was determined by means of clinical criteria. The healing results and the selection of levels were then compared with sealed preoperative...... measurements of the skin perfusion pressure (SPP). Out of 62 BK amputations with an SPP above 30 mmHg wound healing failed in only 2 cases (3 per cent). Out of 13 BK amputations with an SPP between 20 and 30 mmHg 7 cases (54 per cent) failed and out of 9 BK amputations with an SPP below 20 mmHg no less than 8...... cases (89 per cent) failed to heal. The difference in failure rate is significant (P less than 0.0001). Out of the 15 failed BK amputations at low pressures (below 30 mmHg) only one case had local signs of ischaemia, which might have warned the surgeons. On the other hand, in 13 out of the 18 cases...

  12. Invasive intracranial arterial pressure monitoring during endovascular cerebral aneurysms embolization for cerebral perfusion evaluation.

    Science.gov (United States)

    Netlyukh, Andriy M; Shevaga, Volodymyr M; Yakovenko, Leonid M; Payenok, Angelika V; Salo, Victor M; Kobyletskiy, Oleg Ja

    2015-01-01

    The purpose of the study was to define a method of estimation of cerebral blood flow by a determination of parameters of the hemodynamics during neuroendovascular procedures. Materials and Methods. Extracranial and intracranial mean arterial pressure (MAP) was invasively monitored with the help of a transducing system during an endovascular coiling procedure in 19 patients. The measurements were performed at the tip of the guiding catheter and microcatheter placed into internal carotid artery (ICA) C1 segments and of the microcatheter placed into C4 ICA segments, at different stages of the aneurysm repair. Results. As measured, the diameter of the ICA in the C1 and C4 segments did not differ substantially. MAP in the ICA was determined to be 91.2 ± 9.6 mmHg in the skull cavity, and 102.4 ± 6.3 mmHg outside of the skull cavity, with an average difference of 9.2 ± 3.0 mmHg. Conclusion. The difference in MAP, as measured in the ICA outside and inside the skull cavity, was ascribed to the influence of intracranial pressure. Further investigation is required to check the accuracy of invasive intra-arterial pressure recording for an objective and direct measurement of the cerebral perfusion in reference to the intracranial pressure level.

  13. Genome-wide association study identifies six new loci influencing pulse pressure and mean arterial pressure (letter)

    NARCIS (Netherlands)

    Wain, L.V.; Verwoert, G.C.; O'Reilly, P.F.; Shi, G.; Johnson, T.; Johnson, A.D.; Bochud, M.; Rice, K.M.; Henneman, P.; Smith, A.V.; Ehret, G.B.; Amin, N.; Larson, M.G.; Mooser, V.; Hadley, D.; Dorr, M.; Bis, J.C.; Aspelund, T.; Esko, T.; Janssens, A.C.J.W.; Zhao, J.H.; Heath, S.; Laan, M.; Fu, J.Y.; Pistis, G.; Luan, J.A.; Arora, P.; Lucas, G.; Pirastu, N.; Pichler, I.; Jackson, A.U.; Webster, R.J.; Zhang, F.; Peden, J.F.; Schmidt, H.; Tanaka, T.; Campbell, H.; Igl, W.; Milaneschi, Y.; Hottenga, J.J.; Vitart, V.; Chasman, D.I.; Trompet, S.; Bragg-Gresham, J.L.; Alizadeh, B.Z.; Chambers, J.C.; Guo, X.Q.; Lehtimaki, T.; Kuhnel, B.; Lopez, L.M.; Polasek, O.; Boban, M.; Nelson, C.P.; Morrison, A.C.; Pihur, V.; Ganesh, S.K.; Hofman, A.; Kundu, S.; Mattace-Raso, F.U.S.; Rivadeneira, F.; Sijbrands, E.J.G.; Uitterlinden, A.G.; Hwang, S.J.; Vasan, R.S.; Wang, T.J.; Bergmann, S.; Vollenweider, P.; Waeber, G.; Laitinen, J.; Pouta, A.; Zitting, P.; McArdle, W.L.; Kroemer, H.K.; Volker, U.; Volzke, H.; Glazer, N.L.; Taylor, K.D.; Harris, T.B.; Alavere, H.; Haller, T.; Keis, A.; Tammesoo, M.L.; Aulchenko, Y.; Barroso, I.; Khaw, K.T.; Galan, P.; Hercberg, S.; Lathrop, M.; Eyheramendy, S.; Org, E.; Sober, S.; Lu, X.W.; Nolte, I.M.; Penninx, B.W.; Corre, T.; Masciullo, C.; Sala, C.; Groop, L.; Voight, B.F.; Melander, O.; O'Donnell, C.J.; Salomaa, V.; d'Adamo, A.P.; Fabretto, A.; Faletra, F.; Ulivi, S.; Del Greco, M.F.; Facheris, M.; Collins, F.S.; Bergman, R.N.; Beilby, J.P.; Hung, J.; Musk, A.W.; Mangino, M.; Shin, S.Y.; Soranzo, N.; Watkins, H.; Goel, A.; Hamsten, A.; Gider, P.; Loitfelder, M.; Zeginigg, M.; Hernandez, D.; Najjar, S.S.; Navarro, P.; Wild, S.H.; Corsi, A.M.; Singleton, A.; de Geus, E.J.C.; Willemsen, G.; Parker, A.N.; Rose, L.M.; Buckley, B.; Stott, D.; Orru, M.; Uda, M.; van der Klauw, M.M.; Zhang, W.H.; Li, X.Z.; Scott, J.; Chen, Y.D.I.; Burke, G.L.; Kahonen, M.; Viikari, J.; Doring, A.; Meitinger, T.; Davies, G.; Starr, J.M.; Emilsson, V.; Plump, A.; Lindeman, J.H.; 'T Hoen, P.A.C.; Konig, I.R.; Felix, J.F.; Clarke, R.; Hopewell, J.C.; Ongen, H.; Breteler, M.; Debette, S.; DeStefano, A.L.; Fornage, M.; Mitchell, G.F.; Smith, N.L.; Holm, H.; Stefansson, K.; Thorleifsson, G.; Thorsteinsdottir, U.; Samani, N.J.; Preuss, M.; Rudan, I.; Hayward, C.; Deary, I.J.; Wichmann, H.E.; Raitakari, O.T.; Palmas, W.; Kooner, J.S.; Stolk, R.P.; Jukema, J.W.; Wright, A.F.; Boomsma, D.I.; Bandinelli, S.; Gyllensten, U.B.; Wilson, J.F.; Ferrucci, L.; Schmidt, R.; Farrall, M.; Spector, T.D.; Palmer, L.J.; Tuomilehto, J.; Pfeufer, A.; Gasparini, P.; Siscovick, D.; Altshuler, D.; Loos, R.J.F.; Toniolo, D.; Snieder, H.; Gieger, C.; Meneton, P.; Wareham, N.J.; Oostra, B.A.; Metspalu, A.; Launer, L.; Rettig, R.; Strachan, D.P.; Beckmann, J.S.; Witteman, J.C.M.; Erdmann, J.; van Dijk, K.W.; Boerwinkle, E.; Boehnke, M.; Ridker, P.M.; Jarvelin, M.R.; Chakravarti, A.; Abecasis, G.R.; Gudnason, V.; Newton-Cheh, C.; Levy, D.; Munroe, P.B.; Psaty, B.M.; Caulfield, M.J.; Rao, D.C.; Tobin, M.D.; Elliott, P.; van Duijn, C.M.

    2011-01-01

    Numerous genetic loci have been associated with systolic blood pressure (SBP) and diastolic blood pressure (DBP) in Europeans(1-3). We now report genome-wide association studies of pulse pressure (PP) and mean arterial pressure (MAP). In discovery (N = 74,064) and follow-up studies (N = 48,607), we

  14. Effect of Algerian Varieties Dates on Glycemic, Arterial Blood Pressure and Satiety Responses

    Directory of Open Access Journals (Sweden)

    Gourchala Freha, Mihoub Fatma, Derradj Meriem,\tHenchiri Cherifa

    2016-04-01

    Full Text Available The purpose of our study is to determine the Glycemic Indexes (GIsof three Algerians varieties of dates in healthy subjects, evaluate the satiety and effect on arterial pressure after their consumption. We have first documented the chemical composition of the dates. 10 healthy subjects consumed the dates (carbohydrates content of 50 g in order to determine the GIs. The responses of glycaemia were monitored during two hours after the dates taking and compared to the reference glucose. In a randomized trial, 20 healthy adults consumed the dates after 12h of fast. We reported the level of satiety on a Visual Analog Scale for 2h further to the ingestion of the dates. Furthermore, 28 normotensive and 45 hypertensive individuals ingested the three varieties in randomized order during 21 days to assess their impact on the Pressure Arterial Systolic (PAS and Pressure Arterial Diastolic (PAD. We noted significant differences (p<0.05 for the different fractions of sugars, soluble fibers, polyphenols, K+, Mg2+. The low GIs are denoted among 44.31-52.35, deducting a moderate impact on blood glucose level. The dates reduced hunger and increased satiety. Our varieties studied following their ingestion induced a significant hypotensive activity (p<0.05on the PAS and, PAD from hypertensive subjects.

  15. Correlation between Low Serum 25-hydroxyvitamin D Level and High Arterial Blood Pressure%维生素D缺乏与老年高血压的相关性研究

    Institute of Scientific and Technical Information of China (English)

    余华; 朱再胜; 高志立; 邹瑜驰; 杜晓红

    2012-01-01

    目的 探讨维生素D缺乏与老年高血压的相关性.方法 选取2010-2011年在温州医学院附属第一医院门诊就诊或干部病房住院的老年患者316例为研究对象,年龄>60岁,测量并记录其血压水平,抽取静脉血标本,测定血浆25羟基维生素D3(25-OH-Vit D3)和甲状旁腺素(PTH)水平;根据25-OH-Vit D3水平分为维生素D缺乏组(<50 nmol/L)和维生素D不缺乏组(≥50 nmol/L),对比分析两组的收缩压(SBP)、舒张压(DBP)、PTH及血脂水平;并对维生素D缺乏组25-OH-Vit D3水平与SBP、DBP及PTH水平间的关系进行相关性分析及多元线性逐步回归分析.结果 维生素D缺乏组与维生素D不缺乏组患者的性别、年龄、体质指数(BMI)、空腹血糖、Ca2+、血浆清蛋白、肌酐清除率、总胆固醇(TC)、三酰甘油(TG)、低密度脂蛋白胆固醇(LDL-C)水平间差异均无统计学意义(P>0.05);维生素D缺乏组25-OH-Vit D3水平较维生素D不缺乏组降低,而SBP、DBP、PTH水平较维生素D不缺乏组均升高,差异有统计学意义(P<0.05).维生素D缺乏组的25-OH-Vit D3水平与SBP、DBP、PTH水平均呈负相关(r值分别为-0.710、-0.441和-0.581;P<0.05);进一步行多元线性逐步回归分析结果显示:维生素D缺乏组的SBP(β=-40.258)、DBP(β=19.568)、PTH(β=-12.564)与25-OH-Vit D3有相关性(P<0.05),回归方程为25-OH-Vit D3=35.263-0.126 SBP-12.048 PTH+0.094 DBP,方程F=8.605,P<0.05.结论 维生素D缺乏与老年高血压发病相关,适量补充维生素D有可能成为预防和治疗老年高血压的一种简单有效的手段.%Objective To explore the relationship between low serum vitamin D levels and high arterial blood pressure in elderly patients. Methods A total of 316 outpatients and inpatients aged over 60 years treated in our hospital from 2010 to 2011 were enrolled in this study. Blood pressure was measured and recorded and venous blood samples were obtained to determine serum 25

  16. Children and Adolescent Obesity Associates with Pressure-Dependent and Age-Related Increase in Carotid and Femoral Arteries' Stiffness and Not in Brachial Artery, Indicative of Nonintrinsic Arterial Wall Alteration

    Science.gov (United States)

    García-Espinosa, Victoria; Curcio, Santiago; Castro, Juan Manuel; Arana, Maite; Giachetto, Gustavo; Chiesa, Pedro; Zócalo, Yanina

    2016-01-01

    Aim. To analyze if childhood obesity associates with changes in elastic, transitional, and/or muscular arteries' stiffness. Methods. 221 subjects (4–15 years, 92 females) were assigned to normal weight (NW, n = 137) or obesity (OB, n = 84) groups, considering their body mass index z-score. Age groups were defined: 4–8; 8–12; 12–15 years old. Carotid, femoral, and brachial artery local stiffness was determined through systodiastolic pressure-diameter and stress-strain relationships. To this end, arterial diameter and peripheral and aortic blood pressure (BP) levels and waveforms were recorded. Carotid-femoral, femoropedal, and carotid-radial pulse wave velocities were determined to evaluate aortic, lower-limb, and upper-limb regional arterial stiffness, respectively. Correlation analysis between stiffness parameters and BP was done. Results. Compared to NW, OB subjects showed higher peripheral and central BP and carotid and femoral stiffness, reaching statistical significance in subjects aged 12 and older. Arterial stiffness differences disappeared when levels were normalized for BP. There were no differences in intrinsic arterial wall stiffness (elastic modulus), BP stiffness relationships, and regional stiffness parameters. Conclusion. OB associates with BP-dependent and age-related increase in carotid and femoral (but not brachial) stiffness. Stiffness changes would not be explained by intrinsic arterial wall alterations but could be associated with the higher BP levels observed in obese children. PMID:27066273

  17. Microalbuminuria associated with systolic blood pressure and arterial compliance in Chinese metabolic syndrome patients

    Institute of Scientific and Technical Information of China (English)

    LI Xin-li; XU Qiong; TONG Min; LU Xin-zheng; ZHANG Hai-feng; ZHOU Yan-li; CAO Ke-jiang; HUANG Jun

    2007-01-01

    Background There is significant evidence showing that microalbuminuria and arterial compliance are sensitive markers for early cardiovascular diseases. However, whether microalbuminuria is associated with reduced arterial compliance in Chinese metabolic syndrome (MS) patients remains unknown.Methods According to the definition of MS proposed by ATPⅢ in 2001, USA, subjects (n=362) were divided into three groups according to the number of risk factors: group 1 (control), group 2 (medium, < 3 risk factors) and group 3 (MS, ≥ 3 risk factors). Both large artery compliance (C1) and small artery compliance (C2) were measured with the CVProfilor DO-2020 Cardiovascular Profiling System, and microalbuminuria was evaluated with the ratio of albumin to urine creatinine.Results (1) As C1 and C2 levels elasticity decreased, albumin creatinine ratio (ACR) and the prevalence of microalbuminuria increased within those groups with MS risk factors. C1 and C2 were negatively correlated with the ranking of MS risk factors, ACR was positively correlated with the ranking of MS risk factors (all P<0.05). (2) Subjects were also categorized into a microalbuminuria group and a normal group, C1 and C2 in the microalbuminuria group were lower than in the normal group. (3) Multivariate regression analysis showed that increased systolic blood pressure (SBP) and reduced arterial compliance were the main risk factors for microalbuminuria in the MS group.Conclusions The risk of developing microalbuminuria was higher in the subjects with multiple metabolic abnormalities.Increased systolic blood pressure and reduced arterial compliance may be the main predictors for microalbuminuria in MS.

  18. Simulations of piezoelectric pressure sensor for radial artery pulse measurement

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Abhay B. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Kalange, Ashok E. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Tuljaram Chaturchand College, Baramati 413 102 (India); Bodas, Dhananjay, E-mail: dhananjay.bodas@gmail.co [Center for Nanobio Sciences, Agharkar Research Institute, Pune 411 004 (India); Gangal, S.A. [Department of Electronic Science, University of Pune, Pune 411 007 (India)

    2010-04-15

    A radial artery pulse is used to diagnose human body constitution (Prakruti) in Ayurveda. A system consisting of piezoelectric sensor (22 mm x 12 mm), data acquisition card and LabView software was used to record the pulse data. The pulse obtained from the sensor was noisy, even though signal processing was done. Moreover due to large sized senor accurate measurements were not possible. Hence, a need was felt to develop a sensor of the size of the order of finger tip with a resonant frequency of the order of 1 Hz. A micromachined pressure sensor based on piezoelectric sensing mechanism was designed and simulated using CoventorWare. Simulations were carried out by varying dimensions of the sensor to optimize the resonant frequency, stresses and voltage generated as a function of applied pressure. All simulations were done with pressure ranging of 1-30 kPa, which is the range used by Ayurvedic practitioners for diagnosis. Preliminary work on fabrication of such a sensor was carried out successfully.

  19. The giraffe kidney tolerates high arterial blood pressure by high renal interstitial pressure and low glomerular filtration rate.

    Science.gov (United States)

    Damkjaer, M; Wang, T; Brøndum, E; Østergaard, K H; Baandrup, U; Hørlyck, A; Hasenkam, J M; Smerup, M; Funder, J; Marcussen, N; Danielsen, C C; Bertelsen, M F; Grøndahl, C; Pedersen, M; Agger, P; Candy, G; Aalkjaer, C; Bie, P

    2015-08-01

    The tallest animal on earth, the giraffe (Giraffa camelopardalis) is endowed with a mean arterial blood pressure (MAP) twice that of other mammals. The kidneys reside at heart level and show no sign of hypertension-related damage. We hypothesized that a species-specific evolutionary adaption in the giraffe kidney allows normal for size renal haemodynamics and glomerular filtration rate (GFR) despite a MAP double that of other mammals. Fourteen anaesthetized giraffes were instrumented with vascular and bladder catheters to measure glomerular filtration rate (GFR) and effective renal plasma flow (ERPF). Renal interstitial hydrostatic pressure (RIHP) was assessed by inserting a needle into the medullary parenchyma. Doppler ultrasound measurements provided renal artery resistive index (RI). Hormone concentrations as well as biomechanical, structural and histological characteristics of vascular and renal tissues were determined. GFR averaged 342 ± 99 mL min(-1) and ERPF 1252 ± 305 mL min(-1) . RIHP varied between 45 and 140 mmHg. Renal pelvic pressure was 39 ± 2 mmHg and renal venous pressure 32 ± 4 mmHg. A valve-like structure at the junction of the renal and vena cava generated a pressure drop of 12 ± 2 mmHg. RI was 0.27. The renal capsule was durable with a calculated burst pressure of 600 mmHg. Plasma renin and AngII were 2.6 ± 0.5 mIU L(-1) and 9.1 ± 1.5 pg mL(-1) respectively. In giraffes, GFR, ERPF and RI appear much lower than expected based on body mass. A strong renal capsule supports a RIHP, which is >10-fold that of other mammals effectively reducing the net filtration pressure and protecting against the high MAP. © 2015 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  20. Skin perfusion pressure measured by isotope washout in legs with arterial occlusive disease. Evaluation of different tracers, comparison to segmental systolic pressure, angiography and transcutaneous oxygen tension and variations during changes in systemic blood pressure

    DEFF Research Database (Denmark)

    Holstein, P; Trap-Jensen, J; Bagger, H

    1983-01-01

    The skin perfusion pressure (SPP) measured as the isotope washout cessation external pressure is valuable in selection of major amputation level. Five methodological investigations important to clinical use were carried out: (1) In five normal legs and 10 legs with arterial occlusive disease (AOD...... in legs with arterial occlusions at two levels or more; (4) In 47 legs with AOD, the SPP on the calf or on the thigh was compared with transcutaneously measured pO2. The two different methods correlated statistically significant, but the scatter was great; (5) During induced variations in systemic blood...... pressure in seven patients (12 legs with AOD), the segmental SPP and the segmental systolic blood pressure were found on average to vary in proportion with intra-arterial mean and systolic pressure respectively; however, this proportional relationship was not valid for the individual leg. It is concluded...

  1. Plasminogen and fibrinogen plasma levels in coronary artery disease

    Science.gov (United States)

    Lima, Luciana Moreira; Carvalho, Maria das Graças; Sousa, Marinez de Oliveira

    2012-01-01

    Objective The formation of thrombi at the site of atherosclerotic lesions plays a central role in atherothrombosis. Impaired fibrinolysis may exacerbate pre-existing coronary artery disease and potentiate its evolution. While the fibrinogen plasma level has been strongly associated with the severity of coronary artery disease, its relevance in the evaluation of plasminogen in coronary artery disease patients remains unclear. This study evaluated fibrinogen and plasminogen levels in subjects with coronary artery disease as diagnosed by angiography. Methods This is a cross-sectional study. Blood samples obtained from 17 subjects with angiographically normal coronary arteries (controls), 12 with mild/moderate atheromatosis and 28 with severe atheromatosis were evaluated. Plasma plasminogen and fibrinogen levels were measured by chromogenic and coagulometric methods, respectively. Results Fibrinogen levels were significantly higher in the severe atheromatosis group compared to the other groups(p-value < 0.0001). A significant positive correlation was observed between the severity of coronary artery diseaseand increasing fibrinogen levels (r = 0.50; p-value < 0.0001) and between fibrinogen and plasminogen levels (r =0.46; p-value < 0.0001). There were no significant differences in the plasminogen levels between groups. Conclusion Plasma fibrinogen, but not plasminogen levels were higher in patients with coronary artery disease compared to angiographically normal subjects. The plasma fibrinogen levels also appear to be associated with the severity of the disease. The results of this study provide no evidence of a significant correlation between plasma plasminogen levels and the progress of coronary stenosis in the study population. PMID:23049444

  2. Intraspecific scaling of arterial blood pressure in the Burmese python.

    Science.gov (United States)

    Enok, Sanne; Slay, Christopher; Abe, Augusto S; Hicks, James W; Wang, Tobias

    2014-07-01

    Interspecific allometric analyses indicate that mean arterial blood pressure (MAP) increases with body mass of snakes and mammals. In snakes, MAP increases in proportion to the increased distance between the heart and the head, when the heart-head vertical distance is expressed as ρgh (where ρ is the density of blood, G: is acceleration due to gravity and h is the vertical distance above the heart), and the rise in MAP is associated with a larger heart to normalize wall stress in the ventricular wall. Based on measurements of MAP in Burmese pythons ranging from 0.9 to 3.7 m in length (0.20-27 kg), we demonstrate that although MAP increases with body mass, the rise in MAP is merely half of that predicted by heart-head distance. Scaling relationships within individual species, therefore, may not be accurately predicted by existing interspecific analyses.

  3. The blood pressure variability, arterial elasticity and humoral factors in subjects with family history of hypertension.

    Science.gov (United States)

    Rafidah, H M; Azizi, A; Suhaimi, H; Noriah, M N

    2008-03-01

    Normotensive subjects with family history of hypertension (FHT) have been reported to have increased left ventricular mass index and reduced ventricular compliance. Of interest is whether blood pressure variability (BPV), which has been associated with target organ damage, is then part of this complex inherited syndrome? The objectives of this study are to determine whether there are any significant differences in BPV, arterial compliance and humoral factors in subjects with FHT as compared to controls. Thirty-five subjects with self reported FHT and 35 matched controls underwent 24 hour BP monitoring (BR-102, Schiller Inc. Germany). Arterial compliance was measured using systolic pulse wave tonometry (HDI/Pulsewave Cardiovascular Profiling Instrument, Hypertension Diagnostic Inc. USA). None of the subjects were hypertensive or diabetic. Out of these numbers, 25 subjects with FHT and 26 controls had measurements of plasma catecholamines, plasma renin and serum aldosterone. Catecholamines were assayed with high performance liquid chromatography, while both renin and aldosterone measurements were by radioimmunoassay. Subjects with FHT have higher night time BPV. There was no significant difference in arterial compliances between both groups. There were increased level of norepinephrine (NE) in subjects with FHT but epinephrine (E), renin and aldosterone levels were similar in both groups. There were no correlations between NE and BPV but E was negatively associated with daytime and mean arterial systolic BPV. In conclusion subjects with FHT demonstrated a higher night time BPV and NE level as compared to controls.

  4. Accuracy and Precision of Continuous Noninvasive Arterial Pressure Monitoring Compared with Invasive Arterial Pressure: A Systematic Review and Meta-analysis

    National Research Council Canada - National Science Library

    Kim, Sang-Hyun; Lilot, Marc; Sidhu, Kulraj S; Rinehart, Joseph; Yu, Zhaoxia; Canales, Cecilia; Cannesson, Maxime

    2014-01-01

    BACKGROUND:Continuous noninvasive arterial pressure monitoring devices are available for bedside use, but the accuracy and precision of these devices have not been evaluated in a systematic review and meta-analysis...

  5. Failure of unilateral carotid artery ligation to affect pressure-induced interruption of rapid axonal transport in primate optic nerves.

    Science.gov (United States)

    Radius, R L; Schwartz, E L; Anderson, D R

    1980-02-01

    Previous experiments showed that optic nerve axonal transport can be blocked at the level of the lamina cribrosa by elevated intraocular pressure. In an effort to discover if this blockage might be secondary to pressure-induced ischemia, we studied the effect of unilateral common carotid artery ligation upont the pressure-induced interruption of axonal transport. In 13 owl monkeys (Aotus trivirgatus), the right common carotid artery was ligated within the anterior cervical triangle. Three days later, ophtalmodynomometry was performed on all experimental eyes. In nine of the 13 animals, this estimate of ophthalmic artery pressure was 10 to 20 mm Hg less in the right compared to the left eye. Optic nerve axonal transport was studied in right and left eyes during 5 hours of increased intraocular pressure (ocular pressure 35 mm Hg less than mean femoral artery blood pressure). No significant difference in the extent to which the transport mechanisms were interrupted could be demonstrated when comparing right and left eyes of the experimental animals. These observations fail to support a vascular mechanism for this pressure-induced interruption of axonal transport.

  6. Physical activity level in people with high blood pressure Nivel de actividad física en portadores de hipertensión arterial Nível de atividade física em portadores de hipertensão arterial

    Directory of Open Access Journals (Sweden)

    Larissa Castelo Guedes Martins

    2009-08-01

    Full Text Available This study aimed to analyze the level of physical activity for people with high blood pressure cared for in a health center. This cross-sectional study was conducted with 310 individuals between 18 and 69 years of age through the International Physical Activity Questionnaire (IPAQ. The majority (80% of participants presented low or moderate levels of physical activity. The analysis of association between sociodemographic variables and physical activity level revealed that older men from the interior of the state with higher educational levels have a greater chance of exhibiting lower levels of physical activity. The logistic regression model revealed that origin, schooling and diabetes are predictors of low physical activity level. The conclusion is that part of the sample does not match the desirable profile to practice regular physical activity.El objetivo de este estudio fue analizar el nivel de actividad física de personas portadoras de hipertensión arterial, acompañadas en un centro de atención ambulatorial. Se trata de un estudio transversal desarrollado con 310 individuos de 18 a 69 años. Se utilizó como base el International Physical Activity Questionnaire (IPAQ. La mayor parte del grupo (80% fue encuadrada en los niveles de baja y moderada actividad física. En el análisis de asociación entre las variables sociodemográficas y el nivel de actividad física, se verificó que personas del sexo masculino, procedentes del interior del Estado, con más edad y con mayor nivel de escolaridad son más propensas a desarrollar un nivel de actividad física bajo. En el modelo de regresión logística, la procedencia, tiempo de escolaridad y de diabetes fueron indicadores obtenidos como factores de predicción significativos para el nivel bajo de actividad física. Se concluye que parte de la muestra no posee un perfil deseable en relación a la práctica regular de actividad física.O objetivo desse estudo foi analisar o nível de

  7. Determining the Arterial Blood Pressure of People Living in Yesilyurt Local Healthcare Office

    Directory of Open Access Journals (Sweden)

    Feyza Dereli

    2009-02-01

    Full Text Available AIM: Whereas the prevalance of arterial blood pressure which was a chronical health problem was 20%-25% among 30 year-old people, them showing an increase in aging, the percentage went as high as 50% in 60’s and later ages. What was that worrisome was that despite the high prevalance, only half of these received treathment. This is study was descriptively and cross-sectionally planned to determine whether the people asking their tensions to be measured in and around the Yesilyurt local healthcare office region. METHODS: The environment of the research consisted of 1400 people over 35 age and registered Yesilyurt Local healthcare Office and the whole of the environment were included in this sample. The study was conducted over 340 voluntaries. The data was collected by a questionnaire of 14 questions containing socio-demografic features and by measuring the arterial blood pressure, height and weight of the individuals. In the evaluation of the data, chi-square test was used and the level of significantly was accepted as 0.05. RESULTS: In this study, the rate of high sistolic blood pressure was found to be 21.47% and the rate of high diastolic blood pressure to be 8.23%. It was determined that age and body mass index varrieties were effective on sistolic hipertension. It was also found that in their behaviors of the use of hypertensive medicine, of regular arterial pressure controls and of having the hypertesion diagnosis significant differnces varied statistically on both sistolic and diastolic blood pressure people having. CONCLUSION: In order to improve the health, informative information abouth hypertension was provided for the participants for too days consisting of 4 sessions. [TAF Prev Med Bull 2009; 8(1.000: 53-58

  8. [Acute Postoperative Negative Pressure Pulmonary Edema Caused by the Compression of Brachiocephalic Artery].

    Science.gov (United States)

    Tagawa, Miki; Iwai, Hidetaka; Fukatsu, Ken; Shimada, Mami; Hirabayashi, Yoshihiro

    2016-06-01

    We report a case of negative-pressure pulmonary edema occurring by tracheal obstruction caused by the brachiocephalic artery. The patient had deformed thorax with cerebral palsy, which deformed thorax placing the brachiocephalic artery high over the trachea, resulting in close and tight contact between the artery and trachea. Additional deformity of the thorax associated with myotonic attacks after general anesthesia might shorten the distance between the sternal notch and the vertebral body, resulting in the tracheal obstruction by the artery.

  9. Perfusion of veins at arterial pressure increases the expression of KLF5 and cell cycle genes in smooth muscle cells

    Energy Technology Data Exchange (ETDEWEB)

    Amirak, Emre [Section of Molecular Medicine, National Heart and Lung Institute, Imperial College London, Sir Alexander Fleming Building, South Kensington Campus, London SW7 2AZ (United Kingdom); Zakkar, Mustafa; Evans, Paul C. [Cardiovascular Sciences, Bywaters Center for Vascular Inflammation, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, London W12 ONN (United Kingdom); Kemp, Paul R., E-mail: p.kemp@imperial.ac.uk [Section of Molecular Medicine, National Heart and Lung Institute, Imperial College London, Sir Alexander Fleming Building, South Kensington Campus, London SW7 2AZ (United Kingdom)

    2010-01-01

    Vascular smooth muscle cell (VSMC) proliferation remains a major cause of veno-arterial graft failure. We hypothesised that exposure of venous SMCs to arterial pressure would increase KLF5 expression and that of cell cycle genes. Porcine jugular veins were perfused at arterial or venous pressure in the absence of growth factors. The KLF5, c-myc, cyclin-D and cyclin-E expression were elevated within 24 h of perfusion at arterial pressure but not at venous pressure. Arterial pressure also reduced the decline in SM-myosin heavy chain expression. These data suggest a role for KLF5 in initiating venous SMCs proliferation in response to arterial pressure.

  10. Fifteen years experience with finger arterial pressure monitoring : Assessment of the technology

    NARCIS (Netherlands)

    Imholz, B.P.M.; Wieling, W.; Montfrans, G.A. van; Wesseling, K.H.

    1998-01-01

    We review the Finapres technology, embodied in several TNO-prototypes and in the Ohmeda 2300 and 2300e Finapres NIBP. Finapres is an acronym for FINger Arterial PRESsure, the device delivers a continuous finger arterial pressure waveform. Many papers report on the accuracy of the device in compariso

  11. Fifteen years experience with finger arterial pressure monitoring : Assessment of the technology

    NARCIS (Netherlands)

    Imholz, B.P.M.; Wieling, W.; Montfrans, G.A. van; Wesseling, K.H.

    1998-01-01

    We review the Finapres technology, embodied in several TNO-prototypes and in the Ohmeda 2300 and 2300e Finapres NIBP. Finapres is an acronym for FINger Arterial PRESsure, the device delivers a continuous finger arterial pressure waveform. Many papers report on the accuracy of the device in

  12. Body height and arterial pressure in seated and supine young males during +2 G centrifugation

    DEFF Research Database (Denmark)

    Arvedsen, Sine K.; Eiken, Ola; Kölegård, Roger;

    2015-01-01

    by the use of a human centrifuge would increase mean arterial pressure (MAP) more in tall than in short males in the seated position. In short (162-171cm, n=8) and tall (194-203cm, n=10) healthy males (18-41yr), brachial arterial pressure, heart rate (HR) and cardiac output were measured during +2G...

  13. Phytoestrogen genistein decreases contractile response of aortic artery in vitro and arterial blood pressure in vivo

    Institute of Scientific and Technical Information of China (English)

    Hong-fang LI; Long-de WANG; Song-yi QU

    2004-01-01

    AIM: To determine the mechanisms of effects of phytoestrogen genistein on the contracted rabbit aortic arteries in vitro, and observe the effect of genistein and 17-β estradiol on mean arterial pressure (MAP) in ovariectomized (OVX) rats. METHODS: (1) Strips of rabbit aortic smooth muscle were suspended in organ baths containing Kreb's solution, and then isometric tension was measured. (2) Female mature Wistar rats underwent a bilateral ovariectomy (OVX). Sham-operated rats (SHAM) were used as controls. After administration of genistein (0.4(1) Similar to 17-β estradiol, genistein could dose-dependently relax 40 mmol/L KCl-precontracted arterial strips.Incubation with Nω-L-nitro-arginine (L-NNA), methylene blue (MB), indomethacin, propranolol or endothelium removal did not affect relaxation induced by genistein. In calcium-free solution containing 0.01mmol/L egtazic acid (EGTA), genistein inhibited not only the first phase contraction induced by noradrenaline (NA), but also the second contraction induced by CaCl2. In addition, genistein could reduce the contractile responses of NA, KCl and CaCl2,and shift their cumulative concentration-response curves rightward. (2) MAP in OVX rats was significantly higher compared with that of SHAM rats. However, after chronically treatment with genistein or 17-β estradiol for 21 d the baseline MAP in OVX rats was reduced significantly. CONCLUSIONS: (1) The vasodilator effect of genistein in vitro is endothelium independent and not related to the nitric oxide, its mechanisms being probably due to inhibition of Ca2+ influx through calcium channels in a noncompetitive manner and Ca2+ release from intracellular store induced by NA. (2) Administration of genistein or 17-β estradiol can chronically decrease MAP in OVX rats.

  14. [Large artery wall properties in dialyse and renal transplant patients with normal blood pressure].

    Science.gov (United States)

    Posadzy-Małaczyńska, Anna; Kosch, Marcus; Hausberg, Martin; Rahn, Karl H; Małaczyński, Paweł; Głuszek, Jerzy; Tykarski, Andrzej

    2004-01-01

    Structural and mechanical properties of the arterial wall are altered in patients with renal failure. Age and hypertension are known to affect the vessel wall structure. Aging process of arterial wall appears to be accelerated in patients with end-stage renal failure. The mechanisms responsible for reduced arterial compliance and distensibility in dialyse patients and renal transplant recipients without hypertension remain to be evaluated. 20 normotensive dialyse patients (D), 20 normotensive renal transplant recipients (T) and 20 healthy volunteers (N) matched for age, sex and blood pressure as controls were enrolled in to the study. Patients with cardiovascular risk factors and diabetes were excluded. The arterial blood pressure of all patients placed below 140/90 mmHg. The dialyse patients and renal transplant recipients were eligible for the study if the serum creatinine level was below 2 mg/dl. In all subjects, fasting concentrations of serum creatinine, total cholesterol, HDL-cholesterol, LDL-cholesterol, hemoglobin and glucose were determined at enrollment to the study. Long-term immunosuppression consisted of cyclosporine and prednisolone. Blood pressure was measured using an automatic sphygmomanometer (Criticon Dinamap model 1846 SX). Pulse wave velocity (PWV) was evaluated using non-invasive automatic Complior device. The vessel wall properties of the left common carotid artery were studied using multigate pulsed Doppler's system (Pie Medical Equipment BV Maastricht, The Netherlands). The frequency of transducer used was 7.5 MHz. With this non-invasive method, the end-diastolic diameter (d) and the systolic increase of vessel diameter (distension delta d) were measured using ECG trigger. From these data relative systolic increase of vessel diameter (delta d/d) and arterial wall distensibility coefficient (DC) were calculated. Simultaneously with the ultrasound measurements at the left common carotid artery carotid pulse waveforms are recorded using

  15. Vascular flow reserve as a link between long-term blood pressure level and physical performance capacity in mammals

    DEFF Research Database (Denmark)

    Poulsen, Christian B; Damkjær, Mads; Hald, Bjørn O;

    2016-01-01

    Mean arterial pressure (MAP) is surprisingly similar across different species of mammals, and it is, in general, not known which factors determine the arterial pressure level. Mammals often have a pronounced capacity for sustained physical performance. This capacity depends on the vasculature...

  16. Arterial blood pressure is closely related to ascites development in compensated HCV-related cirrhosis.

    Directory of Open Access Journals (Sweden)

    Eduardo Vilar Gomez

    Full Text Available BACKGROUND: Arterial blood pressure (BP is a reliable marker of circulatory dysfunction in cirrhotic patients. There are no prospective studies evaluating the association between different levels of arterial BP and ascites development in compensated cirrhotic patients. Therefore, we evaluated the relationship between arterial BP and ascites development in compensated cirrhotic patients. MATERIALS AND METHODS: A total of 402 patients with compensated HCV-related cirrhosis were prospectively followed during 6 years to identify ascites development. At baseline, patients underwent systolic, diastolic and mean arterial pressure (MAP measurements. Any history of arterial hypertension was also recorded. The occurrence of events such as bleeding, hepatocellular carcinoma, death and liver transplantation prior to ascites development were considered as competing risk events. RESULTS: Over a median of 156 weeks, ascites occurred in 54 patients (13%. At baseline, MAP was significantly lower in patients with ascites development (75.9 mm/Hg [95%CI, 70.3-84.3] than those without ascites (93.6 mm/Hg [95% CI: 86.6-102.3]. After adjusting for covariates, the 6-year cumulative incidence of ascites was 40% (95%CI, 34%-48% for patients with MAP<83.32 mm/Hg. In contrast, cumulative incidences of ascites were almost similar among patients with MAP values between 83.32 mm/Hg and 93.32 mm/Hg (7% [95% CI: 4%-12%], between 93.32 mm/Hg and 100.31 mm/Hg (5% [95% CI: 4%-11%] or higher than 100.31 mm/Hg (3% [95% CI: 1%-6%]. The MAP was an independent predictor of ascites development. CONCLUSIONS: The MAP is closely related to the development of ascites in compensated HCV-related cirrhosis. The risk of ascites development increases in 4.4 fold for subjects with MAP values <83.32 mm/Hg.

  17. Climate Prediction Center Darwin Sea Level Pressure

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This is one of the CPC?s Monthly Atmospheric and SST Indices. It contains Darwin sea level pressures and anomalies during 1951-present. The anomalies are departures...

  18. Pressure Myography to Study the Function and Structure of isolated small arteries

    DEFF Research Database (Denmark)

    Schjørring, Olav; Carlsson, Rune; Simonsen, Ulf

    2015-01-01

    Small arteries play an important role in regulation of peripheral resistance and organ perfusion. Here we describe a series of the methods allowing measurements in pressurized segments of small arteries from the systemic and coronary circulation of mice as well as other species. The pressure...... myography techniques described include measurements of wall structure, wall stress, strain, and of myogenic tone. The pressurized perfused small arteries also allow evaluation of responses to increases in pressure, flow, and drugs, where the main readout is changes in vascular diameter....

  19. Blood pressure and arterial stiffness in obese children and adolescents.

    Science.gov (United States)

    Hvidt, Kristian Nebelin

    2015-03-01

    Obesity, elevated blood pressure (BP) and arterial stiffness are risk factors for cardiovascular disease. A strong relationship exists between obesity and elevated BP in both children and adults. Obesity and elevated BP in childhood track into adult life increasing the risk of cardiovascular disease in adulthood. Ambulatory BP is the most precise measure to evaluate the BP burden, whereas carotid-femoral pulse wave velocity (cfPWV) is regarded as the gold standard for evaluating arterial (i.e. aortic) stiffness. These measures might contribute to a better understanding of obesity's adverse impact on the cardiovascular system, and ultimately a better prevention and treatment of childhood obesity. The overall aim of the present PhD thesis is to investigate arterial stiffness and 24-hour BP in obese children and adolescents, and evaluate whether these measures are influenced by weight reduction. The present PhD thesis is based on four scientific papers.  In a cross-sectional design, 104 severe obese children and adolescents with an age of 10-18 years were recruited when newly referred to the Children's Obesity Clinic, Holbæk University Hospital, and compared to 50 normal weighted age and gender matched control individuals. Ambulatory BP was measured, and cfPWV was investigated in two ways in respect to the distance measure of aorta; the previously recommended length - the so called subtracted distance, and the currently recommended length - the direct distance. In a longitudinal design, the obese patients were re-investigated after one-year of lifestyle intervention at the Children's Obesity Clinic in purpose of reducing the degree of obesity. In the cross-sectional design, the obese group had higher measures of obesity, while matched for age, gender and height, when compared to the control group. In the longitudinal design, 74% of the 72 followed up obese patients experienced a significant weight reduction. CfPWV was dependent on the method used to measure the

  20. Arterial pressure and deltoid muscle gas tensions during cardiopulmonary bypass in man.

    Science.gov (United States)

    Stanley, T H

    1978-07-01

    The results of this study demonstrate that standard techniques of conducting cardiopulmonary bypass produce low muscle oxygen and high muscle carbon dioxide tensions and, thus, little perfusion of skeletal muscle. Our findings also show that PmO2 and PmCO2 do not return to pre-bypass levels until the mean arterial blood pressure exceeds 12 kPa (90 torr) during bypass and that utilization of vasopressor drugs during bypass maintains the pressure; but at the expense of muscle blood flow. The data indicate that both high mean blood pressure and high flow are necessary during bypass to ensure skeletal muscle perfusion and suggest, when combined with preliminary animal findings, that this type of bypass perfusion may prove to be superior to standard techniques in hastening recovery after cardio-pulmonary bypass.

  1. Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement.

    Science.gov (United States)

    Harju, Jarkko; Vehkaoja, Antti; Kumpulainen, Pekka; Campadello, Stefano; Lindroos, Ville; Yli-Hankala, Arvi; Oksala, Niku

    2017-01-19

    Intermittent non-invasive blood pressure measurement with tourniquets is slow, can cause nerve and skin damage, and interferes with other measurements. Invasive measurement cannot be safely used in all conditions. Modified arterial tonometry may be an alternative for fast and continuous measurement. Our aim was to compare arterial tonometry sensor (BPro(®)) with invasive blood pressure measurement to clarify whether it could be utilized in the postoperative setting. 28 patients who underwent elective surgery requiring arterial cannulation were analyzed. Patients were monitored post-operatively for 2 h with standard invasive monitoring and with a study device comprising an arterial tonometry sensor (BPro(®)) added with a three-dimensional accelerometer to investigate the potential impact of movement. Recordings were collected electronically. The results revealed inaccurate readings in method comparison between the devices based on recommendations by Association for the Advancement of Medical Instrumentation (AAMI). On a Bland-Altman plot, the bias and precision between these two methods was 19.8 ± 16.7 (Limits of agreement - 20.1 to 59.6) mmHg, Spearman correlation coefficient r = 0.61. For diastolic pressure, the difference was 4.8 ± 7.7 (LoA - 14.1 to 23.6) mmHg (r = 0.72), and for mean arterial pressure it was 11.18 ± 11.1 (LoA - 12.1 to 34.2) mmHg (r = 0.642). Our study revealed inaccurate agreement (AAMI) between the two methods when measuring systolic and mean blood pressures during post-operative care. The readings for diastolic pressures were inside the limits recommended by AAMI. Movement increased the failure rate significantly (p arterial tonometry is not an appropriate replacement for invasive blood pressure measurement in these patients.

  2. Earliest effects of sudden occlusions on pressure profiles in selected locations of the human systemic arterial system

    Science.gov (United States)

    Majka, Marcin; Gadda, Giacomo; Taibi, Angelo; Gałązka, Mirosław; Zieliński, Piotr

    2017-03-01

    We have developed a numerical simulation method for predicting the time dependence (wave form) of pressure at any location in the systemic arterial system in humans. The method uses the matlab-Simulink environment. The input data include explicitly the geometry of the arterial tree, treated up to an arbitrary bifurcation level, and the elastic properties of arteries as well as rheological parameters of blood. Thus, the impact of anatomic details of an individual subject can be studied. The method is applied here to reveal the earliest stages of mechanical reaction of the pressure profiles to sudden local blockages (thromboses or embolisms) of selected arteries. The results obtained with a purely passive model provide reference data indispensable for studies of longer-term effects due to neural and humoral mechanisms. The reliability of the results has been checked by comparison of two available sets of anatomic, elastic, and rheological data involving (i) 55 and (ii) 138 arterial segments. The remaining arteries have been replaced with the appropriate resistive elements. Both models are efficient in predicting an overall shift of pressure, whereas the accuracy of the 55-segment model in reproducing the detailed wave forms and stabilization times turns out dependent on the location of the blockage and the observation point.

  3. [Effect of infrared laser irradiation on the arterial blood pressure in liquidators of the accident at the Chernobyl power plant].

    Science.gov (United States)

    Korkushko, O O

    2003-01-01

    Liquidators of Tchernobyl accident with discirculatory post-irradiation encephalopathy were treated with infra-red lazer irradiation together with a half doze of pharmacological agents usually used. Infra-red lazer irradiation has been shown to result in a significant reduce in the arterial pressure level, so it can be effective in correcting the disturbances in haemodynamics.

  4. Vascular flow reserve as a link between long-term blood pressure level and physical performance capacity in mammals

    DEFF Research Database (Denmark)

    Poulsen, Christian B; Damkjær, Mads; Hald, Bjørn O

    2016-01-01

    function producing a high precapillary resistance and thus a high vascular flow reserve is associated with an increase in network inlet pressure. Assuming that network properties are independent of body mass, and that inlet pressure of the microvascular network is a proxy for arterial pressure, the study......Mean arterial pressure (MAP) is surprisingly similar across different species of mammals, and it is, in general, not known which factors determine the arterial pressure level. Mammals often have a pronounced capacity for sustained physical performance. This capacity depends on the vasculature...... having a flow reserve that comes into play as tissue metabolism increases. We hypothesize that microvascular properties allowing for a large vascular flow reserve is linked to the level of the arterial pressure.To study the interaction between network properties and network inlet pressure, we developed...

  5. Long-term effects of intermittent Iloprost infusion on pulmonary arterial pressure in connective tissue disease.

    Science.gov (United States)

    Caravita, Sergio; Wu, Sheng Chin; Secchi, Maria Beatrice; Dadone, Viola; Bencini, Chiara; Pierini, Simona

    2011-10-01

    Intravenous periodic Iloprost is proven effective in the treatment of Raynaud phenomenon (RP) related to connective tissue disorder (CTD). It's well known that synthetic prostaglandins are effective drugs for the treatment of pulmonary arterial hypertension (PAH), and that PAH is frequently associated with CTD. The aim of the study is to evaluate in the chronic effect of cyclic intravenous Iloprost on pulmonary arterial pressure. We studied 17 consecutive patients with CTD (14 systemic sclerosis, 3 mixed CTD) and RP, at the entry and after at least 6months of treatment of RP with cyclic Iloprost. On both occasions, in all patients we performed transthoracic Doppler echocardiography and we determined NT-proBNP plasma levels, NYHA functional class, 6 Minute-Walk Distance (6MWD). At follow-up (8.2±1.9months; range 6-12) mean values of pulmonary arterial systolic pressure (PASP) significantly decreased (from 32.2±9.2 to 29.2±7.6mmHg, pIloprost may protect against the development or worsening of PAH in patients with CTD and RP. Copyright © 2011 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  6. RELATIONS BETWEEN DAIRY FOOD INTAKE AND ARTERIAL STIFFNESS: PULSE WAVE VELOCITY AND PULSE PRESSURE

    Science.gov (United States)

    Crichton, Georgina E.; Elias, Merrrill F.; Dore, Gregory A.; Abhayaratna, Walter P.; Robbins, Michael A.

    2012-01-01

    Modifiable risk factors, such as diet, are becomingly increasingly important in the management of cardiovascular disease, one of the greatest major causes of death and disease burden. Few studies have examined the role of diet as a possible means of reducing arterial stiffness, as measured by pulse wave velocity, an independent predictor of cardiovascular events and all-cause mortality. The aim of this study was to investigate whether dairy food intake is associated with measures of arterial stiffness including carotid-femoral pulse wave velocity and pulse pressure. A cross-sectional analysis of a subset of the Maine Syracuse Longitudinal Study sample was performed. A linear decrease in pulse wave velocity was observed across increasing intakes of dairy food consumption (ranging from never/rarely to daily dairy food intake). The negative linear relationship between pulse wave velocity and intake of dairy food was independent of demographic variables, other cardiovascular disease risk factors and nutrition variables. The pattern of results was very similar for pulse pressure, while no association between dairy food intake and lipid levels was found. Further intervention studies are needed to ascertain whether dairy food intake may be an appropriate dietary intervention for the attenuation of age-related arterial stiffening and reduction of cardiovascular disease risk. PMID:22431583

  7. Genome-wide association study identifies six new loci influencing pulse pressure and mean arterial pressure

    Science.gov (United States)

    Wain, Louise V; Verwoert, Germaine C; O’Reilly, Paul F; Shi, Gang; Johnson, Toby; Johnson, Andrew D; Bochud, Murielle; Rice, Kenneth M; Henneman, Peter; Smith, Albert V; Ehret, Georg B; Amin, Najaf; Larson, Martin G; Mooser, Vincent; Hadley, David; Dörr, Marcus; Bis, Joshua C; Aspelund, Thor; Esko, Tõnu; Janssens, A Cecile JW; Zhao, Jing Hua; Heath, Simon; Laan, Maris; Fu, Jingyuan; Pistis, Giorgio; Luan, Jian’an; Arora, Pankaj; Lucas, Gavin; Pirastu, Nicola; Pichler, Irene; Jackson, Anne U; Webster, Rebecca J; Zhang, Feng; Peden, John F; Schmidt, Helena; Tanaka, Toshiko; Campbell, Harry; Igl, Wilmar; Milaneschi, Yuri; Hotteng, Jouke-Jan; Vitart, Veronique; Chasman, Daniel I; Trompet, Stella; Bragg-Gresham, Jennifer L; Alizadeh, Behrooz Z; Chambers, John C; Guo, Xiuqing; Lehtimäki, Terho; Kühnel, Brigitte; Lopez, Lorna M; Polašek, Ozren; Boban, Mladen; Nelson, Christopher P; Morrison, Alanna C; Pihur, Vasyl; Ganesh, Santhi K; Hofman, Albert; Kundu, Suman; Mattace-Raso, Francesco US; Rivadeneira, Fernando; Sijbrands, Eric JG; Uitterlinden, Andre G; Hwang, Shih-Jen; Vasan, Ramachandran S; Wang, Thomas J; Bergmann, Sven; Vollenweider, Peter; Waeber, Gérard; Laitinen, Jaana; Pouta, Anneli; Zitting, Paavo; McArdle, Wendy L; Kroemer, Heyo K; Völker, Uwe; Völzke, Henry; Glazer, Nicole L; Taylor, Kent D; Harris, Tamara B; Alavere, Helene; Haller, Toomas; Keis, Aime; Tammesoo, Mari-Liis; Aulchenko, Yurii; Barroso, Inês; Khaw, Kay-Tee; Galan, Pilar; Hercberg, Serge; Lathrop, Mark; Eyheramendy, Susana; Org, Elin; Sõber, Siim; Lu, Xiaowen; Nolte, Ilja M; Penninx, Brenda W; Corre, Tanguy; Masciullo, Corrado; Sala, Cinzia; Groop, Leif; Voight, Benjamin F; Melander, Olle; O’Donnell, Christopher J; Salomaa, Veikko; d’Adamo, Adamo Pio; Fabretto, Antonella; Faletra, Flavio; Ulivi, Sheila; Del Greco, M Fabiola; Facheris, Maurizio; Collins, Francis S; Bergman, Richard N; Beilby, John P; Hung, Joseph; Musk, A William; Mangino, Massimo; Shin, So-Youn; Soranzo, Nicole; Watkins, Hugh; Goel, Anuj; Hamsten, Anders; Gider, Pierre; Loitfelder, Marisa; Zeginigg, Marion; Hernandez, Dena; Najjar, Samer S; Navarro, Pau; Wild, Sarah H; Corsi, Anna Maria; Singleton, Andrew; de Geus, Eco JC; Willemsen, Gonneke; Parker, Alex N; Rose, Lynda M; Buckley, Brendan; Stott, David; Orru, Marco; Uda, Manuela; van der Klauw, Melanie M; Zhang, Weihua; Li, Xinzhong; Scott, James; Chen, Yii-Der Ida; Burke, Gregory L; Kähönen, Mika; Viikari, Jorma; Döring, Angela; Meitinger, Thomas; Davies, Gail; Starr, John M; Emilsson, Valur; Plump, Andrew; Lindeman, Jan H; ’t Hoen, Peter AC; König, Inke R; Felix, Janine F; Clarke, Robert; Hopewell, Jemma C; Ongen, Halit; Breteler, Monique; Debette, Stéphanie; DeStefano, Anita L; Fornage, Myriam; Mitchell, Gary F; Smith, Nicholas L; Holm, Hilma; Stefansson, Kari; Thorleifsson, Gudmar; Thorsteinsdottir, Unnur; Samani, Nilesh J; Preuss, Michael; Rudan, Igor; Hayward, Caroline; Deary, Ian J; Wichmann, H-Erich; Raitakari, Olli T; Palmas, Walter; Kooner, Jaspal S; Stolk, Ronald P; Jukema, J Wouter; Wright, Alan F; Boomsma, Dorret I; Bandinelli, Stefania; Gyllensten, Ulf B; Wilson, James F; Ferrucci, Luigi; Schmidt, Reinhold; Farrall, Martin; Spector, Tim D; Palmer, Lyle J; Tuomilehto, Jaakko; Pfeufer, Arne; Gasparini, Paolo; Siscovick, David; Altshuler, David; Loos, Ruth JF; Toniolo, Daniela; Snieder, Harold; Gieger, Christian; Meneton, Pierre; Wareham, Nicholas J; Oostra, Ben A; Metspalu, Andres; Launer, Lenore; Rettig, Rainer; Strachan, David P; Beckmann, Jacques S; Witteman, Jacqueline CM; Erdmann, Jeanette; van Dijk, Ko Willems; Boerwinkle, Eric; Boehnke, Michael; Ridker, Paul M; Jarvelin, Marjo-Riitta; Chakravarti, Aravinda; Abecasis, Goncalo R; Gudnason, Vilmundur; Newton-Cheh, Christopher; Levy, Daniel; Munroe, Patricia B; Psaty, Bruce M; Caulfield, Mark J; Rao, Dabeeru C

    2012-01-01

    Numerous genetic loci influence systolic blood pressure (SBP) and diastolic blood pressure (DBP) in Europeans 1-3. We now report genome-wide association studies of pulse pressure (PP) and mean arterial pressure (MAP). In discovery (N=74,064) and follow-up studies (N=48,607), we identified at genome-wide significance (P= 2.7×10-8 to P=2.3×10-13) four novel PP loci (at 4q12 near CHIC2/PDGFRAI, 7q22.3 near PIK3CG, 8q24.12 in NOV, 11q24.3 near ADAMTS-8), two novel MAP loci (3p21.31 in MAP4, 10q25.3 near ADRB1) and one locus associated with both traits (2q24.3 near FIGN) which has recently been associated with SBP in east Asians. For three of the novel PP signals, the estimated effect for SBP was opposite to that for DBP, in contrast to the majority of common SBP- and DBP-associated variants which show concordant effects on both traits. These findings indicate novel genetic mechanisms underlying blood pressure variation, including pathways that may differentially influence SBP and DBP. PMID:21909110

  8. Mean arterial pressure following prolonged exercise in the heat

    DEFF Research Database (Denmark)

    Gagnon, D; Lynn, A G; Binder, K

    2012-01-01

    Prolonged exercise in the heat without fluid replacement represents a significant challenge to the regulation of mean arterial pressure (MAP). It is unknown, however, if MAP is equally challenged during the post-exercise period, and whether regular endurance exercise training can provide any...... benefit to its regulation. We examined MAP (Finometer) in eight trained (T) and eight untrained (UT) individuals prior to, and following, 120 min of cycling at 42 °C with (HYD) and without (DEHY) fluid replacement. Exercise during DEHY induced significant hyperthermia (T: 39.20 ± 0.52 °C vs UT: 38.70 ± 0.......36 °C, P = 0.941) and body weight losses (T: 3.4 ± 1.2% vs UT: 2.7 ± 0.9%, P = 0.332), which did not differ between groups. Although MAP was equally reduced 5 min into the post-exercise period of DEHY (T: -20 ± 11 mmHg vs UT: -22 ± 13 mmHg, P = 0.800), its subsequent recovery was significantly different...

  9. Exercise training improves mean arterial pressure in breast cancer survivors

    Directory of Open Access Journals (Sweden)

    Robert C. Mills

    2014-09-01

    Full Text Available Currently, many breast cancer survivors worldwide live with treatment-related side effects, including cardiovascular health problems. This study examined effects of a 5-month exercise intervention on non-invasive markers of cardiovascular health in breast cancer survivors. Relationships between these markers and commonly used markers of overall health were also explored. Fifty-two survivors completed the exercise training at a rehabilitation center at the University of North Carolina at Chapel Hill between 2008-2011. A combined aerobic and resistance exercise intervention (3 times/week for 1h at intensities progressing from low (40% to moderate (65-70% of VO2max for aerobic and 8-12 repetitions max for the resistance exercise were implemented. Significant reduction in mean arterial pressure (MAP was observed from baseline to final assessment. A significant correlation was found between MAP and Body Mass Index (BMI. In conclusion, 5-months combined aerobic and resistance exercise intervention positively improved MAP which was, in part, attributed to changes in BMI.

  10. Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit.

    Science.gov (United States)

    Langwieser, Nicolas; Prechtl, Luisa; Meidert, Agnes S; Hapfelmeier, Alexander; Bradaric, Christian; Ibrahim, Tareq; Laugwitz, Karl-Ludwig; Schmid, Roland M; Wagner, Julia Y; Saugel, Bernd

    2015-06-01

    Hemodynamic monitoring plays a pivotal role in the treatment of patients in the cardiac intensive care unit (CICU). The innovative radial artery applanation tonometry technology allows for continuous noninvasive arterial blood pressure (AP) measurement. By closing the gap between continuous invasive AP monitoring (arterial catheter) and intermittent noninvasive AP monitoring (oscillometry) this technology might improve CICU patient monitoring. We therefore aimed to evaluate the measurement performance of radial artery applanation tonometry in comparison with a radial arterial catheter in CICU patients. In this prospective method comparison study, we simultaneously recorded AP noninvasively with radial artery applanation tonometry (T-line 200 pro device; Tensys Medical Inc., San Diego, CA, USA) and invasively with an arterial catheter (criterion standard) in 30 patients treated in the CICU of a German university hospital. We statistically analyzed 7,304 averaged 10-beat epochs of measurements of mean AP, systolic AP, and diastolic AP by using Bland-Altman analysis for repeated measurements. Our study revealed a mean difference ± standard deviation (95% limits of agreement; percentage error) between radial artery applanation tonometry and the criterion standard method (radial arterial catheter) of +2 ± 6 mmHg (-10 to +14 mmHg; 17%) for mean AP, -6 ± 11 mmHg (-28 to +15 mmHg; 20%) for systolic AP, and +4 ± 7 mmHg (-9 to +17 mmHg; 23%) for diastolic AP. In CICU patients, continuous noninvasive measurement of AP using radial artery applanation tonometry is feasible. The technology showed reasonable accuracy and precision in comparison with radial arterial catheter-derived AP values.

  11. Effects of renal artery stenting on renal function and blood pressure in patients with atherosclerotic renovascular disease

    Institute of Scientific and Technical Information of China (English)

    张奇; 沈卫峰; 张瑞岩; 张建盛; 胡健; 张宪

    2003-01-01

    Objective To study the effects of percutaneous renal artery intervention on renal function and blood pressure in patients with renal artery stenosis. Methods Eighty-seven patients with severe uni- or bi-lateral renal artery stenosis (luminal diameter narrowing ≥70%) and clinical hypertension received renal artery stenting between January 2002 and December 2002. The changes in blood pressure and serum creatinine level and creatinine clearance (CCr) 48 hours after intervention and during 6 months of follow-up were assessed.Results Renal stenting was performed in 98 stenotic arteries of 87 patients, and the procedural success rate was 100%. Serum creatinine level was slightly elevated from (176±21) μmol/L to (179±11) μmol/L (P=0.15) 48 hours after the procedure, but significantly decreased to (149±15) μmol/L at 6 months (P<0.001). CCr was also greatly improved [(37±11) ml/min before versus (51±8) ml/min at 6 months, P<0.001]. During follow-up, 61% of the patients experienced a normal renal function. Despite conventional medical treatment, systolic and diastolic blood pressures were also significantly decreased after stenting [(163±23)/(96±13) mm Hg before versus (148±12)/(79±15) mm Hg at 6 months, all P<0.001], and hypertension was well controlled in 67% of the patients at 6 months ' follow-up.Conclusion Renal artery stenting has a high success rate and is effective in improving renal function and blood pressure for patients with severe renal artery stenosis.

  12. Dependency of cerebral blood flow upon mean arterial pressure in patients with acute bacterial meningitis

    DEFF Research Database (Denmark)

    Møller, Kirsten; Larsen, Fin Stolze; Qvist, Jesper;

    2000-01-01

    OBJECTIVE: Patients with acute bacterial meningitis are often treated with sympathomimetics to maintain an adequate mean arterial pressure (MAP). We studied the influence of such therapy on cerebral blood flow (CBF). DESIGN: Prospective physiologic trial. SETTING: The Department of Infectious...... Diseases, Copenhagen University Hospital, Denmark. PATIENTS: Sixteen adult patients with acute bacterial meningitis. INTERVENTION: Infusion of norepinephrine to increase MAP. MEASUREMENTS: During a rise in MAP induced by norepinephrine infusion, we measured relative changes in CBF by transcranial Doppler...... bacterial meningitis, CBF autoregulation is impaired. With recovery from meningitis, the cerebral vasculature regains the ability to maintain cerebral perfusion at a constant level despite variations in MAP....

  13. Evaluation of the radial artery applanation tonometry technology for continuous noninvasive blood pressure monitoring compared with central aortic blood pressure measurements in patients with multiple organ dysfunction syndrome.

    Science.gov (United States)

    Meidert, Agnes S; Huber, Wolfgang; Hapfelmeier, Alexander; Schöfthaler, Miriam; Müller, Johannes N; Langwieser, Nicolas; Wagner, Julia Y; Schmid, Roland M; Saugel, Bernd

    2013-12-01

    We compared blood pressure (BP) measurements obtained using radial artery applanation tonometry with invasive BP measurements using a catheter placed in the abdominal aorta through the femoral artery in patients with multiple organ dysfunction syndrome (MODS). In 23 intensive care unit patients with MODS, we simultaneously assessed BP values for 15 minutes per patient using radial artery applanation tonometry (T-Line TL-200 pro device; Tensys Medical Inc, San Diego, Calif) and the arterial catheter (standard-criterion technique). A total of 2879 averaged 10-beat epochs were compared using Bland-Altman plots. The mean difference ± SD (with corresponding 95% limits of agreement) between radial artery applanation tonometry-derived BP and invasively assessed BP was +1.0 ± 5.5 mm Hg (-9.9 to +11.8 mm Hg) for mean arterial pressure, -3.3 ± 11.2 mm Hg (-25.3 to +18.6 mm Hg) for systolic arterial pressure, and +4.9 ± 7.0 mm Hg (-8.8 to +18.6 mm Hg) for diastolic arterial pressure, respectively. In intensive care unit patients with MODS, mean arterial pressure and diastolic arterial pressure can be determined accurately and precisely using radial artery applanation tonometry compared with central aortic values obtained using a catheter placed in the abdominal aorta through the femoral artery. Although systolic arterial pressure could also be derived accurately, wider 95% limits of agreement suggest lower precision for determination of systolic arterial pressure. © 2013.

  14. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement.

    Science.gov (United States)

    Ilies, C; Bauer, M; Berg, P; Rosenberg, J; Hedderich, J; Bein, B; Hinz, J; Hanss, R

    2012-02-01

    Arterial pressure (AP) monitoring should be accurate, easy to use, free of risks, and ideally continuous. The continuous non-invasive arterial pressure (CNAP) device is non-invasive and provides continuous pressure readings. This study was performed to compare the agreement of CNAP and invasive AP monitoring. Ninety patients undergoing surgery under general anaesthesia were enrolled. Invasive pressure monitoring was established at the radial artery. CNAP monitoring using a finger sensor recording was begun before induction of anaesthesia. Statistical analysis was conducted with the Bland-Altman method for comparisons of repeated measures. We obtained 16 843 valid pressure readings from 85 patients. Mean (sd) bias during maintenance of anaesthesia was: systolic AP: 4.2 (16.5) mm Hg; mean AP (MAP): -4.3 (10.4) mm Hg; and diastolic AP: -5.8 (6) mm Hg. The results of a subgroup analysis of patients who had a mean intra-arterial pressure of pressure: -0.3 (9.7) mm Hg; mean pressure: -6.8 (7.6) mm Hg; and diastolic pressure: -7.9 (7.2) mm Hg. Bias and percentage error during the induction period were greater in both the main and subgroup analyses, probably due to recalibration being omitted after induction. The CNAP monitor showed an acceptable agreement and was interchangeable with invasive pressure monitoring for MAP during normotensive conditions. During induction of anaesthesia and when the AP was low, the agreement was less good and interchangeability was not achieved. These results suggest that CNAP is not statistically equivalent to invasive monitoring during all periods of anaesthesia but may be a useful additional AP monitor.

  15. Associations of blood pressure and arterial compliance with occupational noise exposure in female workers of textile mill

    Institute of Scientific and Technical Information of China (English)

    NI Chun-hui; ZHANG Yu-jun; CHEN Zhi-yong; ZHOU Yin; ZHOU Jian-wei; Pan Jing-jing; LIU Nian; WANG Jun; LIANG Chen-ke; ZHANG Zhi-zhong

    2007-01-01

    Background There are few studies on the arterial compliance of noise exposure. The purpose of this study was to understand the relationship between hearing loss, blood pressure and arterial compliance of female workers who exposed to occupational noise in a textile mill.Methods The noise levels in the workplace were measured with a HS6288 sound level meter. Cumulated noise exposure (CNE) was calculated according to the noise intensity and the exposure period. Hearing ability and arterial compliance were measured in 618 noise exposed workers. The database was set up with EpiData and the statistical analysis was performed with SAS software 9.1.3.Results The noise levels were 80.1dB(A) to 113.5dB(A), of which the levels at 92.5% of the noise monitoring sites were over the national standard. The incidence of high frequency hearing loss (HFHL) was 24.43% and language frequency hearing impairment (LFHI) was 0.81%. The incidence of hypertension was 7.93%. Both systolic blood pressure (SBP)and diastolic blood pressure (DBP) in the high frequency hearing loss group were significantly higher than those in the normal hearing group (P<0.05), while C1 (large artery compliance) and C2 (small artery compliance) were significantly lower (P<0.05). The high frequency hearing threshold (HFHT) of the hypertension group was significantly higher than in the normal blood pressure group (P<0.05), while C1 and C2 were significantly lower (P<0.05). C1 and C2 had a negative correlation with HFHT, SBP, DBP, mean of arterial pressure (MAP), pulse pressure (PP) and pulse rate (PR) (P<0.05).The multiple regression analyses showed that blood pressure and PR were the main influencing factors on C1 and C2.LFHT was an influence on C2 and HFHT on C1.Conclusions Textile mill noise pollution is very serious and has an obvious influence on worker's auditory function. The female workers with Iow artery compliance or with high blood pressure might be suffering from hearing loss; those with noise

  16. Arterial blood pressure oscillation after active standing up in kidney transplant recipients.

    Science.gov (United States)

    Gerhardt, U; Schäfer, M; Hohage, H

    2000-04-12

    Dynamic arterial blood pressure (FINAPRES) response to active standing up, normally consisting of initial rise, fall and recovery above the baseline (overshoot), was compared with the early steady-state arterial blood pressure level to measure sympathetic vasomotor function in healthy subjects [group 1: n=50, 10 female subjects, age 51+/-2.5 years; weight 78+/-2.3 kg; height 174+/-1.4 cm (mean+/-standard error of the mean)] and in kidney transplant recipients under basal (group 2a: n=50, age 51.7+/-1.7 years; weight 77+/-2.1 kg; height 174+/-1.5 cm) and under high (group 2b: same subjects as in group 2a) cyclosporine A whole blood levels. Furthermore, baroreflex sensitivity and the activity of the generating compounds of the sympathetic nervous systems (Mayer waves) were measured. Systolic and diastolic overshoot values did not differ statistically significant in the present study. In the control subjects, a systolic overshoot of 15.4+/-2.7 mmHg and a diastolic overshoot of 15.2+/-2 mmHg was detected. The systolic overshoot disappeared in 57% of group 2a (-7.1+/-2.7 mmHg; P<0.001) and in 50% of group 2b recipients (-8.0+/-2.7 mmHg; P<0.001). Systolic early steady-state level was not lower in kidney transplant recipients before cyclosporine (baseline+2 mmHg) intake, but after cyclosporine administration (baseline-3 mmHg; controls: baseline+3 mmHg; P<0.05). There was a strong association between the overshoot and steady-state levels (P for chi(2)<0.001, n=150). Overshoot of group 1 levels (r=0.428; P<0.01) and group 2 levels (r=0.714; P<0. 001) correlated to their respective steady-state blood pressure. Furthermore, recipients had reduced baroreceptor sensitivities estimated by sequence analysis as compared to controls (10+/-1 ms/mmHg vs. 7.5+/-1.4 ms/mmHg; P<0.05). Mayer waves amplitudes of the heart rate spectrum were elevated statistically significant in renal transplant recipients (44.4+/-0.2 vs. 43.8+/-2.2 A.U.). In conclusion, baroreceptor reflex

  17. Influence of geomagnetic activity and atmospheric pressure on human arterial pressure during the solar cycle 24

    Science.gov (United States)

    Azcárate, T.; Mendoza, B.; Levi, J. R.

    2016-11-01

    We performed a study of the systolic (SBP) and diastolic (DBP) arterial blood pressure behavior under natural variables such as the atmospheric pressure (AtmP) and the horizontal geomagnetic field component (H). We worked with a sample of 304 healthy normotense volunteers, 152 men and 152 women, with ages between 18 and 84 years in Mexico City during the period 2008-2014, corresponding to the minimum, ascending and maximum phases of the solar cycle 24. The data was divided by gender, age and day/night cycle. We studied the time series using three methods: Correlations, bivariate and superposed epochs (within a window of three days around the day of occurrence of a geomagnetic storm) analysis, between the SBP and DBP and the natural variables (AtmP and H). The correlation analysis indicated correlation between the SBP and DBP and AtmP and H, being the largest during the night. Furthermore, the correlation and bivariate analysis showed that the largest correlations are between the SBP and DBP and the AtmP. The superposed epoch analysis found that the largest number of significant SBP and DBP changes occurred for women. Finally, the blood pressure changes are larger during the solar minimum and ascending solar cycle phases than during the solar maximum; the storms of the minimum were more intense than those of the maximum and this could be the reason of behavior of the blood pressure changes along the solar cycle.

  18. Serum bilirubin levels, polymorphisms and risk for coronary artery disease

    OpenAIRE

    Lingenhel, Arno; Kollerits, Barbara; Johannes P. Schwaiger; Hunt, Steven C.; Gress, Richard; Hopkins, Paul N.; Schoenborn, Veit; Heid, Iris M; Kronenberg, Florian

    2008-01-01

    Serum bilirubin levels, UGT1A1 polymorphisms and risk for coronary artery disease correspondence: Corresponding author. Tel.: +43 512 9003 70560; fax: +43 512 9003 73560. (Kronenberg, Florian) (Kronenberg, Florian) Division of Genetic Epidemiology; Department of Medical Genetics, Molecular and Clinical Pharmacology; Innsbruck Medical University - AUSTRIA (Lingenhel, Arno) Division of Genetic Epidemiology; Depa...

  19. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  20. Level of arterial ligation in rectal cancer surgery: Low tie preferred over high tie. A review

    NARCIS (Netherlands)

    M.M. Lange (Marilyne); M. Buunen (Mark); C.J.H. van de Velde (Cornelis)

    2008-01-01

    textabstractConsensus does not exist on the level of arterial ligation in rectal cancer surgery. From oncologic considerations, many surgeons apply high tie arterial ligation (level of inferior mesenteric artery). Other strategies include ligation at the level of the superior rectal artery, just cau

  1. Effects of different blood pressure levels on the arterial blood gas of rabbit with uncontrolled hemorrhagic shock during restrictive resuscitation%不同限制性复苏血压水平对出血未控制性休克家兔动脉血气的影响

    Institute of Scientific and Technical Information of China (English)

    程峰; 王振杰; 李磊; 窦贺贺; 邱兆磊; 纪忠; 王子岩

    2012-01-01

    Objective: To observe effects of different blood pressure levels on the arterial blood gas of rabbit with uncontrolled hemorrhagic shock during restrictive resuscitation and explore the ideal blood pressure levels for uncontrolling hemorrhagic shock. Methods: Model with uncontrolled hemorrhagic shock was established according to modifed Wigger's describtion. Twenty-four rabbits in the model were randomly divided into 4 groups(6 in each group) ,noresuscitation(NR) group as control,N50,N60 and N70 groups with maintaining mean arterial pressure( MAP) at 50,60 and 70 mmHg respectively. The arterial blood gas analysis( ABGA) including lactic acid, base excess, arterial oxygen tension, arterial carbon dioxide tension and potential of hydrogen were detected before shock and at 0, 60,120,150,180 and 240 minutes after shock. Results:The data of ABGA of N60 group were better than those of other groups at all time-points. Conclusions: During restrictive resuscitation of the rabbits with unconrntrolled hemorrhagic shock, maintaining MAP at 60 mmHg has little effect on their ABGA. The results suggest that MAP at 60 mmHg is suitable level for the restrictive resuscitation.%目的:观察不同限制性复苏血压水平对出血未控制性休克家兔动脉血气的影响,探讨出血未控制性休克复苏时应维持的理想血压水平.方法:采用Wigger改良法制作出血未控制性休克模型,24只家兔随机分为4组(n=6).NR组:不复苏组;N50组:复苏维持平均动脉压(mean arterial pressure,MAP)在50 mmHg水平;N60组:复苏维持MAP在60 mmHg水平;N70组:复苏维持MAP在70 mmHg水平;在休克前、休克后0、60、120、150、180、240 min检测动脉血气分析,包括血乳酸、剩余碱、氧分压、二氧化碳分压、pH值等指标.结果:N60组氧分压、二氧化碳分压、乳酸、pH值在各个时间点均优于其他组(P<0.05).结论:失血性休克家兔在出血未控制前行限制性液体复苏时,维持MAP在60 mmHg对动脉

  2. Arterial compliance in patients with cirrhosis: stroke volume-pulse pressure ratio as simplified index

    DEFF Research Database (Denmark)

    Henriksen, J H; Fuglsang, Stefan; Bendtsen, Flemming;

    2001-01-01

    Arterial function may be altered in patients with cirrhosis. We determined compliance of the arterial tree (C(1)) in relation to systemic and splanchnic hemodynamic derangement and clinical variables. C(1) and the stroke volume-pulse pressure index (SV/PP) were significantly higher (+62% and +40...... predictors of SV/PP (P index seems to reflect abnormalities in the arterial compliance of these patients....

  3. Arterial compliance in patients with cirrhosis: stroke volume-pulse pressure ratio as simplified index

    DEFF Research Database (Denmark)

    Fuglsang, S; Bendtsen, F; Christensen, E

    2001-01-01

    Arterial function may be altered in patients with cirrhosis. We determined compliance of the arterial tree (C(1)) in relation to systemic and splanchnic hemodynamic derangement and clinical variables. C(1) and the stroke volume-pulse pressure index (SV/PP) were significantly higher (+62% and +40...... predictors of SV/PP (P compliance is elevated in cirrhosis. A simplified SV/PP index seems to reflect abnormalities in the arterial compliance of these patients....

  4. Validation of continuous noninvasive arterial blood pressure measurements during general anesthesia

    NARCIS (Netherlands)

    Kalmar, A.F.; Vos, Jaap Jan; Weening, M.; Mooyaart, E.A.; Poterman, Marieke; Struys, Michel; Scheeren, Thomas

    2012-01-01

    Background:  Continuous invasive arterial blood pressure (IBP) monitoring remains the accepted gold standard for blood pressure monitoring because of its high accuracy. Several disadvantages of this method motivate the use of noninvasive intermittent blood pressure (NIBP) in most anesthesia cases

  5. Validation of continuous noninvasive arterial blood pressure measurements during general anesthesia

    NARCIS (Netherlands)

    Kalmar, A.F.; Vos, Jaap Jan; Weening, M.; Mooyaart, E.A.; Poterman, Marieke; Struys, Michel; Scheeren, Thomas

    2012-01-01

    Background:  Continuous invasive arterial blood pressure (IBP) monitoring remains the accepted gold standard for blood pressure monitoring because of its high accuracy. Several disadvantages of this method motivate the use of noninvasive intermittent blood pressure (NIBP) in most anesthesia cases de

  6. Strength training reduces arterial blood pressure but not sympathetic neural activity in young normotensive subjects

    Science.gov (United States)

    Carter, Jason R.; Ray, Chester A.; Downs, Emily M.; Cooke, William H.

    2003-01-01

    The effects of resistance training on arterial blood pressure and muscle sympathetic nerve activity (MSNA) at rest have not been established. Although endurance training is commonly recommended to lower arterial blood pressure, it is not known whether similar adaptations occur with resistance training. Therefore, we tested the hypothesis that whole body resistance training reduces arterial blood pressure at rest, with concomitant reductions in MSNA. Twelve young [21 +/- 0.3 (SE) yr] subjects underwent a program of whole body resistance training 3 days/wk for 8 wk. Resting arterial blood pressure (n = 12; automated sphygmomanometer) and MSNA (n = 8; peroneal nerve microneurography) were measured during a 5-min period of supine rest before and after exercise training. Thirteen additional young (21 +/- 0.8 yr) subjects served as controls. Resistance training significantly increased one-repetition maximum values in all trained muscle groups (P training did not affect MSNA or heart rate. Arterial blood pressures and MSNA were unchanged, but heart rate increased after 8 wk of relative inactivity for subjects in the control group (61 +/- 2 to 67 +/- 3 beats/min; P = 0.01). These results indicate that whole body resistance exercise training might decrease the risk for development of cardiovascular disease by lowering arterial blood pressure but that reductions of pressure are not coupled to resistance exercise-induced decreases of sympathetic tone.

  7. Pressão arterial, excesso de peso e nível de atividade física em estudantes de universidade pública Blood pressure, excess weight and level of physical activity in students of a public university

    Directory of Open Access Journals (Sweden)

    Maria do Carmo de Carvalho e Martins

    2010-08-01

    Full Text Available FUNDAMENTO: A hipertensão arterial, o excesso de peso e o sedentarismo são importantes fatores de risco para doenças cardiovasculares e estão fortemente associados. OBJETIVO: Avaliar o estado nutricional, o nível de atividade física e os níveis de pressão arterial de estudantes da Universidade Federal do Piauí, em Teresina. MÉTODOS: Estudo transversal com amostra de 605 estudantes (46,1% do sexo masculino e 53,9% do feminino, com média de idade de 21,7 ± 3,7 anos. O estado nutricional global foi classificado pelo índice de massa corporal (IMC e a adiposidade central pela circunferência da cintura (CC. O nível de atividade física foi avaliado utilizando-se o Questionário Internacional de Atividade Física (IPAQ na versão curta. A pressão arterial aumentada foi definida como uma pressão sistólica > 140 mmHg e/ou diastólica > 90 mmHg. RESULTADOS: A prevalência de pressão arterial aumentada foi de 9,7%, sendo maior em homens. Excesso de peso (IMC > 25 kg/m² foi encontrado em 18,2% dos estudantes, sendo as proporções de sobrepeso e obesidade de 15,2% e 3%, respectivamente. Obesidade abdominal foi encontrada em 2,4% dos estudantes, independentemente do gênero, e o sedentarismo em 52%. A pressão arterial média aumentou com o incremento do IMC e da CC. Não houve associação entre os níveis de atividade física e pressão arterial. CONCLUSÃO: Houve associação entre aumento do peso corporal e da circunferência da cintura com maiores níveis de pressão arterial entre os pesquisados. É necessário estabelecer instrumentos de avaliação precoce do risco cardiovascular e promover orientação preventiva para esses jovens.BACKGROUND: High blood pressure, excess weight and sedentary lifestyle are important risk factors for cardiovascular diseases, and they are closely associated. OBJECTIVE: To evaluate the nutritional status, level of physical activity and blood pressure levels of students of Universidade Federal do Piau

  8. Pressão arterial e concentração plasmática do peptídeo atrial natriurético e do peptídeo natriurético tipo B, em gestações complicadas pela pré-eclâmpsia Influence of atrial natriuretic peptide and type B natriuretic peptide plasma levels on arterial pressure in pregnancies complicated by preeclampsia

    Directory of Open Access Journals (Sweden)

    Zilma Silveira Nogueira Reis

    2003-07-01

    Full Text Available OBJETIVO: o estudo busca determinar a existência de associação entre a elevação da pressão arterial e os níveis plasmáticos dos peptídeos natriuréticos ANP e BNP, na gestação complicada pela pré-eclâmpsia. MÉTODOS: em estudo transversal caso-controle, pareado por idade gestacional, 25 grávidas normotensas e 61 portadoras de pré-eclâmpsia foram avaliadas quanto ao nível da pressão arterial e às concentrações plasmáticas dos peptídeos natriuréticos ANP e BNP. Exames clínico e laboratoriais foram realizados para o diagnóstico de pré-eclâmpsia, sendo a pressão arterial medida de forma não invasiva. As dosagens hormonais foram obtidas por radioimunoensaio, após extração em colunas Sep-pak C18. Os valores médios das concentrações plasmáticas do ANP e BNP foram comparados entre grupos com pressão arterial progressivamente maiores. A correlação entre os valores da pressão arterial e os níveis plasmáticos do ANP e BNP no sangue materno foi também investigada pela de análise de regressão no grupo completo de gestantes e em grupos específicos excluindo-se a hipertensão anterior à gestação e, em seguida, excluindo-se aquelas sem hipertensão prévia. RESULTADOS: os valores plasmáticos de ANP foram 41.5±7.3, 78.4±13.1 e 89.2±13.4 pg/mL (pPURPOSE: to determine the existence of association between blood pressure rise and plasma ANP and BNP levels in pregnancies complicated by preeclampsia, considering the existence of a hypertensive state before pregnancy and supportive drug influence on these hormones. METHODS: in a case-control transversal study, 86 pregnant women were assessed regarding arterial pressure level and plasma ANP and BNP levels. Clinical and laboratory tests were carried out to diagnose preeclampsia and the use of hypotensive drugs and magnesium sulfate was considered. Hormone determinations were obtained through radioimmunoassay, after extraction in C18 Sep-pak columns. Correlation was

  9. Effects of ovarian stimulation on blood pressure and plasma catecholamine levels.

    Science.gov (United States)

    Tollan, A; Oian, P; Kjeldsen, S E; Holst, N; Eide, I

    1993-07-01

    Effects of ovarian stimulation for in vitro fertilization on blood pressure and plasma catecholamine levels were studied in 10 women. The examinations were carried out before hormonal treatment with human menopausal gonadotropin (day three of the menstrual cycle, mean serum oestradiol concentration 0.2 nmol l-1, and on the day after ovulation induction with human chorionic gonadotropin (cycle days 10-12, mean serum oestradiol concentration 7.4 nmol l-1). Systolic and diastolic blood pressures (mean +/- SD) decreased 6.7 +/- 8.6 mm Hg, p = 0.049, and 5.3 +/- 4.7 mm Hg, p = 0.009, respectively), and venous plasma noradrenaline increased (42 +/- 44 pg ml-1, p = 0.02) during ovarian stimulation. No significant change was observed in either arterial noradrenaline, arterial adrenaline or venous adrenaline. After stimulation a positive correlation was observed between systolic blood pressure and arterial adrenaline (r = 0.73, p = 0.027), and between systolic blood pressure and the arterial-venous difference for adrenaline (r = 0.81, p = 0.007). The increased venous noradrenaline levels may be a reflex-mediated activation of the sympathetic nervous tone due to a decrease in blood pressure, or may indicate reduced neuronal re-uptake of released noradrenaline. The mechanisms behind the strong correlation between adrenaline and blood pressure are unclear, but may be induced by the supraphysiological oestradiol levels. Thus, adrenaline seems to be more important for blood pressure control in this particular setting.

  10. Middle cerebral artery occlusion in presence of low perfusion pressure increases infarct size in rats

    DEFF Research Database (Denmark)

    Sillesen, H; Nedergaard, Majken; Schroeder, T;

    1988-01-01

    A model was set up in order to evaluate the importance of hemispheric perfusion pressure when the middle cerebral artery (MCA) is occluded in anaesthetized rats. In 6 animals the internal carotid artery (ICA) was occluded prior to ipsilateral MCA occlusion; in 17 animals the MCA only was occluded...

  11. Arterial pressure during cardiopulmonary bypass is not associated with acute kidney injury

    DEFF Research Database (Denmark)

    Kandler, K; Jensen, M E; Nilsson, J C

    2015-01-01

    underwent coronary artery bypass grafting with or without concomitant procedures was conducted. AKI was defined using the RIFLE criteria. Data on arterial pressure and use of norepinephrine during cardiopulmonary bypass were entered in a binary logistic regression model to control for possible perioperative...

  12. Gender-specific association of the plasminogen activator inhibitor-1 4G/5G polymorphism with central arterial blood pressure.

    Science.gov (United States)

    Björck, Hanna M; Eriksson, Per; Alehagen, Urban; De Basso, Rachel; Ljungberg, Liza U; Persson, Karin; Dahlström, Ulf; Länne, Toste

    2011-07-01

    The functional plasminogen activator inhibitor-1 (PAI-1) 4G/5G polymorphism has previously been associated with hypertension. In recent years, central blood pressure, rather than brachial has been argued a better measure of cardiovascular damage and clinical outcome. The aim of this study was to investigate the possible influence of the 4G/5G polymorphism on central arterial blood pressure in a cohort of elderly individuals. We studied 410 individuals, 216 men and 194 women, aged 70-88. Central pressures and pulse waveforms were calculated from the radial artery pressure waveform by the use of the SphygmoCor system and a generalized transfer function. Brachial pressure was recorded using oscillometric technique (Dinamap, Critikon, Tampa, FL). PAI-1 antigen was determined in plasma. The results showed that central pressures were higher in women carrying the PAI-1 4G/4G genotype compared to female carriers of the 5G/5G genotype, (P = 0.025, P = 0.002, and P = 0.002 for central systolic-, diastolic-, and mean arterial pressure, respectively). The association remained after adjustment for potentially confounding factors related to hypertension. No association of the PAI-1 genotype with blood pressure was found in men. Multiple regression analysis revealed an association between PAI-1 genotype and plasma PAI-1 levels (P = 0.048). Our findings show a gender-specific association of the PAI-1 4G/5G polymorphism with central arterial blood pressure. The genotype effect was independent of other risk factors related to hypertension, suggesting that impaired fibrinolytic potential may play an important role in the development of central hypertension in women.

  13. The value of arterial pressure waveform cardiac output measurements in the radial and femoral artery in major cardiac surgery patients

    NARCIS (Netherlands)

    van Drumpt, A.; J. van Bommel (Jasper); S.E. Hoeks (Sanne); F. Grüne (Frank); T. Wolvetang (Timothy); J.A. Bekkers (Jos); M. Horst, ter (Maarten)

    2017-01-01

    textabstractBackground: A relatively new uncalibrated arterial pressure waveform cardiac output (CO) measurement technique is the Pulsioflex-ProAQT® system. Aim of this study was to validate this system in cardiac surgery patients with a specific focus on the evaluation of a difference in the radial

  14. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry......, the oscillometry showed a positive predictive value of 47%. The presence of PAD was significantly correlated to exercise related leg pain, a diagnosis of hypertension and smoking, whereas no correlation could be found with a diagnosis of heart disease, stroke, or with the presence of diabetes. The prevalence...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  15. Arterial blood-pressure change and endogenous circulating substance P in man

    DEFF Research Database (Denmark)

    Henriksen, J H; Kastrup, J; Schaffalitzky De Muckadell, O B

    1985-01-01

    Substance P (SP) is a powerful vasodilator and this peptide is today considered to be a chemical messenger. The potential effects on circulating SP of acute changes in arterial blood-pressure was investigated in nine subjects. An increase in arterial mean blood-pressure (+33%, P less than 0.001, n...... within the reference interval: 3-16 pmol/l (n.s.). Plasma SP remained very constant in each subject during the changes in blood-pressure (mean variation in plasma concentration of SP was 0.97 (SD) pmol/l). The results show that acute changes in arterial blood-pressure do not result in any detectable...... change in plasma SP, this seems to indicate that endogenous circulating SP has no significant role in the vascular tonus controlled by the arterial baroreflex....

  16. An Inexpensive Arterial Pressure Wave Sensor and its application in different physiological condition

    CERN Document Server

    Sur, S; Sur, Shantanu

    2005-01-01

    Arterial Blood Pressure wave monitoring is considered to be important in assessment of cardiovascular system. We developed a novel pulse wave detection system using low frequency specific piezoelectric material as pressure wave sensor. The transducer detects the periodic change in the arterial wall diameter produced by pressure wave and the amplified signal after integration represents the pressure wave. The signal before integration is proportional to the rate of change of pressure wave and it not only reproduces the pressure waveform faithfully, but also its sharper nature helps to reliably detect the heart period variability (HPV). We have studied the position-specific (e.g. over carotid or radial artery) nature of change of this pulse wave signal (shape and amplitude) and also the changes at different physiological states.

  17. Relationship between Glycosylated Hemoglobin, Serum Nitric Oxide and Mean Arterial Blood Pressure.

    Science.gov (United States)

    Manju, M; Mishra, Sasmita; Toora, B D; Vijayakumar; Vinod, R

    2014-12-01

    Hypertension is about twice as frequent in individuals with diabetes as in those without diabetes. Formation of glycosylated conjugates like HbA1c is implicated to have many effects on the vascular endothelium which leads to the development of hypertension in diabetes. Nitric oxide (NO)-dependent vasodilatation has been shown to be an important factor in the maintenance and regulation of peripheral vascular tone. Studies correlating these parameters give conflicting results. Hence the present study was designed to correlate HbA1c, Serum NO & mean arterial blood pressure. To study the relationship between glycosylated hemoglobin, serum nitric oxide & mean arterial blood pressure. It is a case control study with 28 type 2 diabetic hypertensives, 32 type 2 diabetic normotensives and 51 controls (non diabetic normotensives). The study subjects included 28 type 2 diabetic hypertensives, 32 type 2 diabetic normotensives and 51 controls (non diabetic normotensives) [ADA 2010 and JNC7]. FBS, PPBS, PCV, Hb, HbA1c & serum NO estimation and BP recording was done in all the study subjects. Normalised mean arterial blood pressure (MAPn) and calculated glycosylated hemoglobin (cHbA1c) were calculated from mean arterial BP (MAP) and HbA1c respectively. was done using R commander software. The difference in the distribution of cHbA1c, MAPn & NO levels between all 3 groups was measured using ANOVA and Kruskal-Wallis test. Correlation between the parameters was measured by Correlation coefficient and logistic regression (Spearman linear regression) analysis (univariate and multivariate). There was a significant difference in the distribution of cHbA1c, MAPn & NO levels (p<0.001) between all 3 groups, whether measured by ANOVA or Kruskal-Wallis test. On univariate analysis, there was a positive correlation between cHbA1c & MAPn (ρ= +0.26), a negative correlation between NO & MAPn (ρ = -0.54) and cHbA1c & NO (ρ= -0.66) .On multivariate analysis, not only NO, but contrary to

  18. Fundamental relations between short-term RR interval and arterial pressure oscillations in humans

    Science.gov (United States)

    Taylor, J. A.; Eckberg, D. L.

    1996-01-01

    BACKGROUND: One of the principal explanations for respiratory sinus arrhythmia is that it reflects arterial baroreflex buffering of respiration-induced arterial pressure fluctuations. If this explanation is correct, then elimination of RR interval fluctuations should increase respiratory arterial pressure fluctuations. METHODS AND RESULTS: We measured RR interval and arterial pressure fluctuations during normal sinus rhythm and fixed-rate atrial pacing at 17.2+/-1.8 (SEM) beats per minute greater than the sinus rate in 16 healthy men and 4 healthy women, 20 to 34 years of age. Measurements were made during controlled-frequency breathing (15 breaths per minute or 0.25 Hz) with subjects in the supine and 40 degree head-up tilt positions. We characterized RR interval and arterial pressure variabilities in low-frequency (0.05 to 0.15 Hz) and respiratory-frequency (0.20 to 0.30 Hz) ranges with fast Fourier transform power spectra and used cross-spectral analysis to determine the phase relation between the two signals. As expected, cardiac pacing eliminated beat-to-beat RR interval variability. Against expectations, however, cardiac pacing in the supine position significantly reduced arterial pressure oscillations in the respiratory frequency (systolic, 6.8+/-1.8 to 2.9 +/-0.6 mm Hg2/Hz, P=.017). In contrast, cardiac pacing in the 40 degree tilt position increased arterial pressure variability (systolic, 8.0+/-1.8 to 10.8 +/-2.6, P=.027). Cross-spectral analysis showed that 40 degree tilt shifted the phase relation between systolic pressure and RR interval at the respiratory frequency from positive to negative (9 +/-7 degrees versus -17+/-11 degrees, P=.04); that is, in the supine position, RR interval changes appeared to lead arterial pressure changes, and in the upright position, RR interval changes appeared to follow arterial pressure changes. CONCLUSIONS: These results demonstrate that respiratory sinus arrhythmia can actually contribute to respiratory arterial

  19. Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testing.

    Science.gov (United States)

    Sipkens, Laura M; Treskes, Kaij; Ariese-Beldman, Karin; Veerman, Derk P; Boer, Christa

    2011-10-01

    Evaluation of autonomic function responses is increasingly important for risk prediction and hemodynamic evaluation in the ambulant and perioperative setting, but requires a noninvasive arterial blood pressure measurement device. This study describes whether a novel noninvasive beat-to-beat arterial blood pressure measurement device (Nexfin HD) is able to reproducibly reflect autonomic function responses in healthy volunteers. Noninvasive beat-to-beat arterial blood pressure measurements (Nexfin HD) were performed in 20 healthy men of 22 ± 3 years. Measurements were performed during supine steady state, controlled breathing (0.125 Hz), passive leg raising, a controlled Valsalva maneuver, and a quick stand test. Finally, relative changes in pulse pressure during autonomic function testing and the test-retest reproducibility were determined. Autonomic function tests induced beat-to-beat arterial blood pressure changes that were accurately monitored by the Nexfin device. The intraclass correlation coefficients for systolic and diastolic arterial blood pressure measurements during supine steady state were agreeable [0.91 (0.82-0.96) and 0.84 (0.69-0.93), respectively]. The reproducibility of blood pressure changes during controlled breathing, passive leg raising, and Valsalva maneuver averaged 0.92 (0.82-0.96), 0.76 (0.50-0.90), and 0.94 (0.89-0.97), respectively. The reproducibility of the pulse pressure variation (PPV) as calculated from controlled breathing-induced changes in the arterial blood pressure (13 ± 5%) was high [0.96 (0.93-0.98)]. This study shows that noninvasive beat-to-beat Nexfin HD arterial blood pressure measurements reproducibly reflect autonomic function responses in healthy volunteers.

  20. Arterial Pulse Pressure and Its Association With Reduced Stroke Volume During Progressive Central Hypovolemia

    Science.gov (United States)

    2006-09-01

    Measurement of Stroke Volume Stroke volume (SV) was measured noninvasively using thoracic electrical bioimpedance (TEB). TEB was measured using four...tients who did not die. For the current study, we measured mean arterial blood pressure (MAP), pulse pressure (PP), SV, and muscle sympathetic nerve...hemorrhagic shock. The vital sign monitors placed in emergency transport vehicles provide the medic with routine measures of arterial systolic, diastolic and

  1. Non-invasive assessment of pulmonary arterial pressure in healthy neonates.

    OpenAIRE

    Skinner, J. R.; Boys, R J; Hunter, S; Hey, E N

    1991-01-01

    Doppler echocardiograms were carried out on 51 healthy babies three times during the first 72 hours of life to estimate pulmonary arterial systolic pressure by measuring regurgitant tricuspid jet velocity and applying the Bernoulli equation. Tricuspid regurgitation was detected at some stage in all preterm babies and most of those born at full term. Pulmonary arterial pressure could be measured from peak regurgitant velocity in babies with pansystolic regurgitation. The incidence of pansystol...

  2. Association of sleep duration with arterial blood pressure profile of Gujarati Indian adolescents

    Directory of Open Access Journals (Sweden)

    Shaikh Wasim

    2010-01-01

    Full Text Available Background and Aim: Recently, National Health and Nutritional Examination Survey-1 data analysis found short sleep duration as a risk factor for hypertension in the U.S. population. However, since ethnic differences exist in the aetiopathogenesis of diseases, the current study was undertaken to study the effect of sleep duration on the blood pressure profile of Gujarati Indian adolescents. Materials and Methods: A cross-sectional study was conducted on 489 Gujarati Indian adolescents of age group 16-19 years studying in school and colleges in the local population. The participants were assessed for their sleep duration, physical activity status, body composition, blood pressure profile and cardiovascular reactivity. The sleep duration was reported by the subjects as the number of hours they slept on most of the nights in a week over the last one year. The observations of the study were then analyzed after grouping them into: 1 Adequate Sleep Duration at Night, ASDN (≥ 7 hrs and 2 Inadequate Sleep Duration at Night, ISDN (< 7 hrs groups. Student′s unpaired t-test was used to study if any significant difference (P< 0.05 existed between the groups. Results: No significant difference was found in Systolic blood pressure, Diastolic blood pressure, Pulse pressure and Mean arterial pressure between the ASDN group and the ISDN group. Physical activity status also did not differ between the two groups. However, adolescents of ISDN group showed a significantly higher level of adiposity and cardiovascular reactivity as compared to adolescents of ASDN group. Conclusion: Although short sleep duration is associated with a higher level of adiposity and cardiovascular reactivity in Gujarati Indian adolescents, it does not affect the resting blood pressure profile of these adolescents. However, longitudinal studies would be required to observe if the changes in adiposity and cardiovascular reactivity affect these adolescents in later life.

  3. Effects of hypoproteinemia on renal hemodynamics, arterial pressure, and fluid volume

    Energy Technology Data Exchange (ETDEWEB)

    Manning, R.D. Jr.

    1987-01-01

    The effects of long-term hypoproteinemia on renal hemodynamics, arterial pressure, and fluid volume were studied in eight conscious dogs over a 34-day period. Plasma protein concentration (PPC) was decreased by daily plasmapheresis, and the effects of decreasing and increasing sodium intake were measured. By the 12th day of plasmapheresis PPC had decreased to 2.5 g/dl from a control value of 7.2 g/dl, mean arterial pressure had decreased to 78% of control, glomerular filtration rate (GFR) was 75.2% of control, and urinary sodium excretion was decreased. By day 18 of plasmapheresis, estimated renal plasma flow (ERPF) was decreased to 60% of control due to the decreased arterial pressure and an increase in renal vascular resistance. GFR and ERPF were determined from the total clearance of (/sup 125/I)iothalamate and (/sup 131/I)iodohippurate. Also, plasma renin activity and plasma aldosterone concentration were both increased, and the relationship between mean arterial pressure and urinary sodium excretion was distinctly shifted to the left along the arterial pressure axis. In contradistinction to acute experiments, chronic hypoproteinemia results in decreases in GFR, ERPF, and urinary sodium excretion and has marked effects on both fluid volume and arterial pressure regulation.

  4. Distribuição de gordura corporal, pressão arterial e níveis de lipídios-lipoproteínas plasmáticas Body fat distribution, blood pressure and plasma lipids and lipoprotein levels

    Directory of Open Access Journals (Sweden)

    Dartagnan Pinto Guedes

    1998-02-01

    Full Text Available OBJETIVO: Investigar associações entre distribuição do tecido adiposo e níveis de pressão arterial e concentrações de lipídios-lipoproteínas plasmáticas, mediante controle de indicadores, quanto à quantidade de gordura corporal e à prática da atividade física. MÉTODOS: Estudo de 62 indivíduos com idades entre 20 e 45 anos. A distribuição do tecido adiposo foi determinada baseando-se na relação circunferência de cintura/quadril (CCQ, e como indicador da quantidade de gordura corporal recorreu-se às informações do índice de massa corporal (IMC, enquanto o nível de prática da atividade física foi estabelecido mediante estimativas do consumo máximo de oxigênio (VO2max. As associações entre CCQ e níveis de pressão arterial e de lipídios-lipoproteínas plasmáticas, com os efeitos do IMC e do VO2max controlados estatisticamente, foram estabelecidas pelo coeficiente de correlação parcial. RESULTADOS: Após correção pelo IMC verificou-se significativa correlação parcial entre a distribuição centrípeta do tecido adiposo e os níveis de pressão arterial, LDL-C e triglicerídios plasmáticos. Entretanto, controlando-se o VO2max, não foram constatadas associações significativas entre CCQ e qualquer variável sangüínea e pressão arterial.CONCLUSÃO: A distribuição centrípeta do tecido adiposo, independente da quantidade de gordura corporal, foi relacionada com concentrações de lipídios-lipoproteínas plasmáticas e níveis de pressão arterial em ambos os sexos. A prática da atividade física parece ser um importante modulador dessa associação, enfatizando seu papel no controle dos fatores de risco predisponentes às doenças cardiovasculares.PURPOSE: To study associations between FAT distribution and blood pressure levels and concentrations of lipids and lipoproteins, irrespective of body fat content and physical activity. METHODS: A sample of 62 subjects of both genders aging 20-45 years-old was

  5. Continuous Right Radial Arterial Pressure Monitoring as a Guide to Dissection of a Thoracic Inlet Neurofibroma.

    Science.gov (United States)

    Ravindra, Madhavi Nishtala

    2015-09-01

    Excision of tumors in the thoracic inlet entail a risk of injury to subclavian vessels due to their close proximity. A right radial artery line can sensitively and continuously monitor the occurrence of right subclavian artery compression and warn the surgeon of its proximity and prevent injury. We describe a case of thoracic inlet tumor in a 12-year-old child, wherein the use of radial artery pressure monitoring guided the surgeon to separate the subclavian artery from the tumor to which it was adherent. © The Author(s) 2015.

  6. Capsaicin, arterial hypertensive crisis and acute myocardial infarction associated with high levels of thyroid stimulating hormone.

    Science.gov (United States)

    Patanè, Salvatore; Marte, Filippo; Di Bella, Gianluca; Cerrito, Marco; Coglitore, Sebastiano

    2009-05-01

    Chili peppers are rich in capsaicin. The potent vasodilator calcitonin gene-related peptide (CGRP) is stored in a population of C-fiber afferents that are sensitive to capsaicin. CGRP and peptides released from cardiac C fibers have a beneficial effect in myocardial ischemia and reperfusion. It has been reported that capsaicin pretreatment deplete cardiac C-fiber peptide stores. Furthermore, it has also been reported that capsaicin-treated pigs significantly increase mean arterial blood pressure compared with controls and that the decrease in CGRP synthesis and release contributes to the elevated blood pressure. It has also been reported that sub-clinical hypothyroidism is associated with a significant risk of coronary heart disease (CHD). We present a case of arterial hypertensive crisis and acute myocardial infarction in a 59-year-old Italian man with high levels of thyroid stimulating hormone and with an abundant ingestion of peppers and of chili peppers which occurred the day before.

  7. Ambulatory blood pressure monitoring and structural changes in carotid arteries in normotensive workers occupationally exposed to lead.

    Science.gov (United States)

    Poreba, Rafał; Poreba, Małgorzata; Gać, Paweł; Andrzejak, Ryszard

    2011-09-01

    Occupational exposure to lead may cause an increase in blood pressure. The aim of the study was to estimate the effect of occupational exposure to lead on selected parameters of ambulatory blood pressure monitoring (ABPM) and structural changes in carotid arteries. The study included 33 normotensive men occupationally exposed to lead and 39 unexposed men employed in administration of the foundry. All of the men underwent 24-hour ambulatory blood pressure monitoring and high-resolution B-mode ultrasonography to determine intima-media thickness (IMT). The group of men occupationally exposed to lead manifested significantly higher mean systolic blood pressure (MSBP), mean diastolic blood pressure (MDBP), mean blood pressure (MBP), pulse pressure (PP), variability of diastolic blood pressure (VDBP), and IMT than the unexposed group. The studied groups did not differ in mean values of variability of systolic blood pressure (VSBP). As compared to the unexposed group, in men exposed to lead, atherosclerotic plaques were significantly more common. In the group of persons exposed to lead the Pearson's correlation coefficient analysis revealed significant linear positive correlations between MSBP and IMT, between lead level and the number of atherosclerotic plaques, and between lead level and PP. Multivariate stepwise regression analysis demonstrated that higher lead level in blood and higher triglyceride concentration in blood represent independent risk factors of an increased pulse pressure in the group of individuals occupationally exposed to lead. Occupational exposure to lead can be associated with increased blood pressure and accelerated progression of atherosclerosis.

  8. Classification of peripheral occlusive arterial diseases based on symptoms, signs and distal blood pressure measurements

    DEFF Research Database (Denmark)

    Tønnesen, K H; Noer, Ivan; Paaske, William

    1980-01-01

    Systolic blood pressures at toe and ankle were measured in 459 consecutive patients with occlusive arterial disease. Fifty-eight per cent had intermittent claudication with arterial disease of all degrees of severity. Seventeen per cent complained of rest pain having toe systolic pressures below 30...... mmHg, half had arterial lesions proximal to the groin. None had diabetes. Fourteen per cent non-diabetic patients had chronic ulcerations on the foot with arterial lesions similar to those in patients with rest pain. Eleven per cent diabetic patients with chronic ulcerations had less pronounced...... occlusive arterial disease which was located distally on the legs. A classification in three groups is suggested: (1) ischemia only during exercise; (2) ischemia at rest with or without ulcerations: and (3) diabetics with chronic ulcerations....

  9. Comparison of continuous non-invasive finger arterial pressure monitoring with conventional intermittent automated arm arterial pressure measurement in patients under general anaesthesia

    NARCIS (Netherlands)

    Vos, J. J.; Poterman, M.; Mooyaart, E. A. Q.; Weening, M.; Struys, M. M. R. F.; Scheeren, T. W. L.; Kalmar, A. F.

    Background: For a majority of patients undergoing anaesthesia for general surgery, mean arterial pressure (MAP) is only measured intermittently by arm cuff oscillometry (MAP(iNIAP)). In contrast, the Nexfin (R) device provides continuous non-invasive measurement of MAP (MAP(cNIAP)) using a finger

  10. Reduction of mean arterial pressure and proteinuria by the effect of ACEIs (Lisinopril) in Kurdish hypertensive patients in Hawler City.

    Science.gov (United States)

    Muslih, A I

    2012-06-30

    The angiotensin converting enzyme inhibitors (ACEIs) are a group of pharmaceuticals that are used primarily in treatment of hypertension and congestive heart failure, in some cases as the drugs of first choice. The renin-angiotensin system is activated in response to hypotension, decreased sodium concentration in the distal tubule, decreased blood volume and in renal sympathetic nerve stimulation. This study examines the effects of angiotensin converting enzyme inhibitor (Lisinopril) on blood pressure (BP) 131 ± 2.4 and proteinuria 0.198 ± 0.005 in Kurd hypertensive patients, mean arterial blood pressure and proteinuria excretion were measured weekly along the period of 12 weeks. Lisinopril significantly reduced mean arterial blood pressure, and attenuated proteinuria level in patients subjected to this study in lisinopril 10mg dose dependent manner (p<0.05, n=24). In conclusion, lisinopril is of beneficial of renoprotection and in lowering BP.

  11. Validation of the pulse decomposition analysis algorithm using central arterial blood pressure.

    Science.gov (United States)

    Baruch, Martin C; Kalantari, Kambiz; Gerdt, David W; Adkins, Charles M

    2014-07-08

    There is a significant need for continuous noninvasive blood pressure (cNIBP) monitoring, especially for anesthetized surgery and ICU recovery. cNIBP systems could lower costs and expand the use of continuous blood pressure monitoring, lowering risk and improving outcomes.The test system examined here is the CareTaker® and a pulse contour analysis algorithm, Pulse Decomposition Analysis (PDA). PDA's premise is that the peripheral arterial pressure pulse is a superposition of five individual component pressure pulses that are due to the left ventricular ejection and reflections and re-reflections from only two reflection sites within the central arteries.The hypothesis examined here is that the model's principal parameters P2P1 and T13 can be correlated with, respectively, systolic and pulse pressures. Central arterial blood pressures of patients (38 m/25 f, mean age: 62.7 y, SD: 11.5 y, mean height: 172.3 cm, SD: 9.7 cm, mean weight: 86.8 kg, SD: 20.1 kg) undergoing cardiac catheterization were monitored using central line catheters while the PDA parameters were extracted from the arterial pulse signal obtained non-invasively using CareTaker system. Qualitative validation of the model was achieved with the direct observation of the five component pressure pulses in the central arteries using central line catheters. Statistically significant correlations between P2P1 and systole and T13 and pulse pressure were established (systole: R square: 0.92 (p pressures obtained through the conversion of PDA parameters to blood pressures of non-invasively obtained pulse signatures with catheter-obtained blood pressures fell within the trend guidelines of the Association for the Advancement of Medical Instrumentation SP-10 standard (standard deviation: 8 mmHg(systole: 5.87 mmHg, diastole: 5.69 mmHg)). The results indicate that arterial blood pressure can be accurately measured and tracked noninvasively and continuously using the CareTaker system and the PDA algorithm. The

  12. [THE INFLUENCE OF CYTOFLAVIN AND CARDIOXIPIN ON THE PARAMETERS OF 24-HOUR ARTERIAL PRESSURE MONITORING IN PATIENTS WITH CHRONIC CEREBRAL CIRCULATION INSUFFICIENCY, ARTERIAL HYPERTENSION AND HYPERCHOLESTEROLEMIA].

    Science.gov (United States)

    Vodop'ianova, O A; Moiseeva, I Ia; Rodina, O P; Kustikova, I N; Antropova, N V

    2015-01-01

    This comparative study of the influence of cytoflavin and cardioxipin on the parameters of 24-hour arterial pressure monitoring in 56 patients with chronic cerebral circulation insufficiency, arterial hypertension and hypercholesterolemia included 32 women and 24 men aged 42-72 years divided into 3 groups matchedfor the stage of diseases, age, sex, severity of AH, total cholesterol level, and antihypertensive therapy. Patients of group 1 were treated without cytoflavin and cardioxipin. Those in group 2 received daily i/v droplet infusion of 10 mg/kg cardioxipin (20-30 droplets/min). Patients of group 3 were given daily i/v droplet infusion of 10 ml cytoflavin in 200 ml 0.9% sodium chloride solution for 10 days. 24-hour arterial pressure monitoring was used to estimate the influence of the two drugs on systolic and diastolic pressure, its daily rhythm, AP variability and frequency of elevation. The study showed that both therapeutic modalities improved daily AP rhythm as manifested in a significant increase of the number of patients with the dipper rhythm and a decrease in the number of systolic/diastolic non-dipper patients. Moreover cytoflavin significantly decreased the number of systolic over-dippers compared with control group.

  13. Effects of changing body position on oxygenation and arterial blood pressures in foals anesthetized with guaifenesin, ketamine, and xylazine.

    Science.gov (United States)

    Braun, Christina; Trim, Cynthia M; Eggleston, Randy B

    2009-01-01

    To investigate the impact of a change in body position on blood gases and arterial blood pressures in foals anesthetized with guaifenesin, ketamine, and xylazine. Prospective, randomized experimental study. Twelve Quarter Horse foals, age of 5.4 +/-0.9 months and weighing 222 +/- 48 kg. Foals were anesthetized with guaifenesin, ketamine, and xylazine for 40 minutes in lateral recumbency and then assigned to a change in lateral recumbency after hoisting (Group 1, n = 6), or no change (Group 2, n = 6). Oxygen 15 L minute(-1) was insufflated into the endotracheal tube throughout anesthesia. Arterial blood pressure, heart rate, respiratory rate (f(R)), inspired fraction of oxygen (FIO(2)), and end-tidal carbon dioxide (PE'CO(2)) were measured every 5 minutes. Arterial pH and blood gases [arterial partial pressure of oxygen (PaO(2)), arterial partial pressure of carbon dioxide (PaCO(2))] were measured at 10, 30, and 40 minutes after induction, and 5 minutes after hoisting. Alveolar dead space ventilation and PaO(2)/FIO(2) were calculated. Two repeated measures models were used. All hypothesis tests were two-sided and significance level was alpha = 0.05. All values are presented as least square means +/- SE. Values at time-matched points from the two groups were not significantly different so they were combined. Arterial partial pressure of oxygen decreased significantly from 149 +/- 14.4 mmHg before hoisting to 92 +/- 11.6 mmHg after hoisting (p = 0.0013). The PaO(2)/FIO(2) ratio decreased from 275 +/- 30 to 175 +/- 24 (p = 0.0055). End-tidal carbon dioxide decreased significantly from 48.7 +/- 1.6 to 44.5 +/- 1.2 mmHg (p = 0.021). Arterial partial pressure of carbon dioxide, blood pressures and heart rates measured 5 minutes after hoisting were not different from measurements obtained before hoisting. Hoisting decreased PaO(2) in anesthetized healthy foals. Administration of supplemental oxygen is recommended to counter the decrease in oxygenation and PaO(2

  14. Application of exercise transcutaneous oxygen pressure measurements for detection of proximal lower extremity arterial disease: a case report.

    Science.gov (United States)

    Mahe, Guillaume; Kalra, Manju; Abraham, Pierre; Liedl, David A; Wennberg, Paul W

    2015-06-01

    Proximal claudication is secondary to ischemia caused by peripheral artery disease (PAD), whereas proximal pseudo-claudication is secondary to other disease processes such as hip arthritis, spinal stenosis, neuropathy, and so forth. The differentiation between the two can be challenging. Exercise transcutaneous oxygen pressure measurement (exercise-TcPO2) allows noninvasive detection of flow-reducing lesions in the proximal arteries and tributaries of the lower extremity arterial tree. We present the first case report in the United States using an exercise-TcPO2 algorithm. A 71-year-old diabetic patient with proximal left-sided and right-calf claudication with indeterminate ankle-brachial indices underwent an exercise-TcPO2 study before and after endovascular intervention. Four TcPO2 probes were placed: one at chest level (reference probe), one on each buttock, and one on the symptomatic calf. The Delta from Resting Oxygen Pressure (DROP) index was calculated at each probe site using a previously validated protocol. Proximal left- and right-calf ischemia were confirmed by the initial exercise-TcPO2, and, after endovascular treatment of the left iliac artery lesion, improvements in proximal exercise-TcPO2 values were found. These data suggest that exercise-TcPO2 can be useful in PAD evaluation in patients with non-compressible arteries and/or proximal claudication.

  15. Basis of monitoring central blood pressure and hemodynamic parameters by peripheral arterial pulse waveform analyses.

    Science.gov (United States)

    Miyashita, Hiroshi; Katsuda, Shin-ichiro

    2013-01-01

    In hypertension clinics, central blood pressure (CBP) should be estimated, instead of directly measured, by the "signal processing" of a noninvasive peripheral pressure waveform. This paper deals with the data obtained in our three separate studies focusing on a major estimation method, i.e., radial artery late systolic shoulder pressure (rSBP2)-based CBP estimation. Study 1: Using a wave separation analysis of precise animal data of pressure wave transmission along the upper-limb arteries, we first demonstrate that pulse pressure amplification is largely attributable to local wave reflection alone. Study 2: A frequency component analysis of simultaneously recorded human central and radial artery pressure waveforms showed a predominance of lower (1st+2nd) harmonic components in determining the central augmentation peak amplitude. The features of a central pressure waveform, including its phase property, may contribute to the less-altered transmission of augmentation peak pressure to rSBP2. Study 3: Comparisons of noninvasive rSBP2 with direct or estimated central systolic blood pressure (cSBP) revealed broad agreement but also augmentation-dependent biases. Based on the features of the biases as well as the counterbalanced relationship between pulse pressure amplification and the transmission-induced alterations of augmentation peak amplitude observed in Study 2, we propose an improved cSBP estimate, SBPm, the simple arithmetic mean of rSBP2 and peripheral systolic blood pressure.

  16. Changes in Doppler waveforms can predict pressure reduction across internal carotid artery stenoses

    DEFF Research Database (Denmark)

    Sillesen, H; Schroeder, T

    1988-01-01

    perfusion pressure. Forty-nine patients were examined consecutively with ultrasound Doppler prior to carotid endarterectomy. Pulsatility index (PI), pulse rise-time (RT), and systolic width (SW) were related to angiographic degree of stenosis and the ratio of distal ICA blood pressure to common carotid...... artery (CCA) blood pressure (ICA/CCA pressure ratio). The latter was determined during surgery. All three waveform parameters were significantly correlated with the ICA/CCA pressure ratio when calculated from the mean frequency curve (p less than 0.001). A reduction in ICA pressure of 20% could...

  17. Fluid input control in burned patients with the aid of ultrasonic arterial blood pressure monitoring.

    Science.gov (United States)

    Banssillon, V; Latarjet, J

    1975-01-01

    Arterial blood pressure is nowadays easily and reliably measured with ultrasonic equipment. It correlates well with blood volume, and may therefore be used to guide fluid infusion in burned patients. Monitoring of blood pressure, instead of application of old-fashioned recipes, helps to avoid dangerous situations of hypovolemia or overload.

  18. Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study.

    Science.gov (United States)

    Jacq, Gwenaëlle; Gritti, Karine; Carré, Cécile; Fleury, Nadège; Lang, Annie; Courau-Courtois, Josette; Bedos, Jean-Pierre; Legriel, Stephane

    2015-09-01

    Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care unit in 2009 to 2011 and fulfilling our inclusion criteria. Four combinations (B-E) of transducer level, catheter access site, and patient position were compared with a reference combination (A) (A: patient supine with all catheters in the same plane and a single transducer level (M) for zero point reference (Z) aligned on the phlebostatic axis; B: 45° head-of-bed elevation with M and Z aligned on the phlebostatic axis; C: 45° head-of-bed elevation with M aligned on the catheter access site and Z on the phlebostatic axis; D: 45° head-of-bed elevation with M and Z aligned on the catheter access site; and E: 45° head-of-bed elevation with M aligned on the phlebostatic axis and Z on the catheter access site). We included 103 patients, 68 men and 35 women, with a median age of 69 years (interquartile range [IQR], 56-78); at inclusion, 91 (88.3%) received mechanical ventilation, 45 (43.7%) catecholamines, and 66 (64.1%) sedation. The IAPM access site was femoral in 49 (47.6%) and radial in 54 (52.4%) patients, with 62 of 103 (60.2%) catheters on the right side. Measured absolute mean arterial pressure values were significantly higher with 3 study combinations (C-E) than with the reference combination (A). After adjustment, the differences versus A (median, 83 [IQR, 74-92] mm Hg) remained significant for D (median, 91 [IQR, 85-100] mm Hg, P arterial pressure values. For patients in the 45° head-of-bed elevation position, aligning the Z on the phlebostatic axis provides values that are not significantly different from those obtained using the reference supine modality.

  19. Accuracy in Blood Pressure Monitoring: The Effect of Noninvasive Blood Pressure Cuff Inflation on Intra-arterial Blood Pressure Values.

    Science.gov (United States)

    Sheshadri, Veena; Tiwari, Akhilesh Kumar; Nagappa, Mahesh; Venkatraghavan, Lashmi

    2017-01-01

    Both invasive and noninvasive blood pressure (invasive arterial blood pressure [IABP] and noninvasive BP [NIBP]) monitors are used perioperatively; however, they often produce different values. The reason for this discrepancy is not clear, and it is possible that the act of cuff inflation itself might affect the IABP values, especially with the recurrent cycling of NIBP cuff. The aim of this study was to determine the effect of ipsilateral NIBP cuff inflation on the contralateral IABP values. Prospective, observational study. One hundred consecutive patients were studied. The NIBP device was set to cycle every 5 min for a total of 6 times. During each cuff inflation cycle, changes in IABP values from the arterial line in the contralateral arm were recorded. A total of 582 measurements were included for data analysis. Chi-square, paired t-test, analysis of variance. Mean (± standard deviation) changes in systolic BP (SBP), diastolic BP, and mean BP with cuff inflation were 6.7 ± 5.9, 2.6 ± 4.0, and 4.0 ± 3.9 mmHg, respectively. We observed an increase of 0-10 mmHg in SBP in majority (73.4%) of cuff inflations. The changes in IABP did not differ between the patients with or without hypertension or with the baseline SBP. This study showed that there is a transient reactive rise in IABP values with NIBP cuff inflation. This is important information in the perioperative and intensive care settings, where both these measurement techniques are routinely used. The exact mechanism for this effect is not known but may be attributed to the pain and discomfort from cuff inflation.

  20. A prospective study of glomerular filtration rate and arterial blood pressure in insulin-dependent diabetics with diabetic nephropathy

    DEFF Research Database (Denmark)

    Parving, H H; Smidt, U M; Friisberg, B

    1981-01-01

    nephropathy. Twelve of the 14 patients had normal serum creatinine levels. None of the patients received antihypertensive treatment. During the mean observation period of 26 months (range 23 to 33 months) GFR decreased from 107 to 87 ml/min/1.73 m2 (p less than 0.001), serum creatinine remained unchanged: 107...... in arterial blood pressure to a hypertensive level is an early feature of diabetic nephropathy in young insulin-dependent diabetics.......Glomerular filtration rate (GFR, single bolus 51Cr-EDTA technique), serum creatinine, proteinuria and arterial blood pressure have been measured prospectively in 14 young onset insulin-dependent diabetics selected by of persistent proteinuria (greater than 0.5 g/day) secondary to diabetic...

  1. Carotid arterial blood pressure waveform monitoring using a portable ultrasound system.

    Science.gov (United States)

    Joohyun Seo; Pietrangelo, Sabino J; Hae-Seung Lee; Sodini, Charles G

    2015-08-01

    This work presents a non-invasive arterial blood pressure (ABP) waveform monitoring technique using ultrasound. A portable ultrasound system to excite ultrasound transducers and acquire data is designed with off-the-shelf components. The insonation angles are identified using a vector Doppler technique based on the cosine dependency of the Doppler signals. The pulse pressure of an estimated waveform at the left common carotid artery is compared to the standard sphygmomanometer measurement in a clinical test. The estimated carotid ABP waveform shows excellent agreement to the finger ABP waveform with expected discrepancy of the systolic peak shape due to different measurement sites. The proposed method also tracks slow blood pressure fluctuations. This validation on human subjects shows potential for a noninvasive blood pressure waveform monitoring device at central arterial sites.

  2. Low-pressure pulmonary artery aneurysm presenting with pulmonary embolism: a case series

    Directory of Open Access Journals (Sweden)

    Papoulidis Pavlos

    2011-04-01

    Full Text Available Abstract Introduction Pulmonary artery aneurysm is an uncommon disorder with severe complications. The diagnosis is often difficult, since the clinical manifestations are non-specific and the treatment is controversial, as the natural history of the disease is not completely understood. Case presentation We describe the cases of two patients with pulmonary artery aneurysms. The first patient was a 68-year-old Caucasian man with an idiopathic low-pressure pulmonary artery aneurysm together with a pulmonary embolism. The patient preferred a conservative approach and was stable at the 10-month follow-up visit after being placed on anti-coagulant treatment. The second patient was a 66-year-old Caucasian woman with a low-pressure pulmonary artery aneurysm also presented together with a pulmonary embolism. The aneurysm was secondary to pulmonary valve stenosis. She received anti-coagulants and, after stabilization, underwent percutaneous balloon valvuloplasty. Conclusion Pulmonary embolism may be the initial presentation of a low-pressure pulmonary artery aneurysm. No underlying cause for pulmonary embolism was found in either of our patients, suggesting a causal association with low-pressure pulmonary artery aneurysm.

  3. Comparison of how well conscious cats tolerate blood pressure measurement from the radial and coccygeal arteries.

    Science.gov (United States)

    Cannon, Martha J; Brett, Jo

    2012-12-01

    Hypertension is a common condition of older cats and acquiring clinically relevant and repeatable blood pressure (BP) measurements in conscious cats is important in its diagnosis and management. The most common sites for indirect BP measurement in the cat are the radial artery (RA) and the coccygeal artery (CA) but, to date, there are no published data comparing how conscious cats tolerate BP measurements from these sites. A high-definition oscillometric BP monitor was used to measure BP in 30 cats admitted to a cat-only veterinary clinic for reasons other than hypertension. Systolic arterial pressure (SAP), mean arterial pressure (MAP) and diastolic arterial pressure (DAP) were measured using the RA and CA, alternating which site was used first. The number of failed attempts and total time to achieve six measurements was recorded. Measurement of BP using the CA was better tolerated than the RA, resulting in fewer failures and shorter total time required. SAP measurements were slightly higher from the CA compared with the RA, irrespective of which site was used first. There were no significant differences in MAP and DAP. The coccygeal artery appears to be the more appropriate site to use when measuring BP in conscious cats using this oscillometric machine. Further studies are required using alternative BP monitors, including Doppler machines, to establish whether this is a consistent finding. When measuring BP in cats the site used should be recorded and the same site used for all subsequent measurements from the same cat.

  4. Ambulatory arterial stiffness index derived from 24-hour ambulatory blood pressure monitoring.

    Science.gov (United States)

    Li, Yan; Wang, Ji-Guang; Dolan, Eamon; Gao, Ping-Jin; Guo, Hui-Feng; Nawrot, Tim; Stanton, Alice V; Zhu, Ding-Liang; O'Brien, Eoin; Staessen, Jan A

    2006-03-01

    We hypothesized that 1 minus the slope of diastolic on systolic pressure during 24-hour ambulatory monitoring (ambulatory arterial stiffness index [AASI]) might reflect arterial stiffness. We compared AASI with established measures of arterial stiffness and studied its distribution in Chinese and European populations. We used 90207 SpaceLabs monitors and the SphygmoCor device to measure AASI, central and peripheral pulse pressures, the central (CAIx) and peripheral (PAIx) systolic augmentation indexes, and aortic pulse wave velocity. In 166 volunteers, the correlation coefficient between AASI and pulse wave velocity was 0.51 (Ppressure (r=0.50). AASI increased with age and mean arterial pressure but decreased with body height. Both before and after adjustment for arterial wave reflections by considering height and heart rate as covariates, AASI correlated more (Ppressure. Among normotensive subjects, the 95th percentile of AASI was 0.55 in Chinese and 0.57 in 1617 Europeans enrolled in the International Database on Ambulatory Blood Pressure Monitoring. The upper boundary of the 95% prediction interval of AASI in relation to age ranged from 0.53 at 20 years to 0.72 at 80 years. In conclusion, AASI is a new index of arterial stiffness that can be easily measured under ambulatory conditions. Pending additional validation in outcome studies, normal values of AASI are probably <0.50 and 0.70 in young and older subjects, respectively.

  5. ASSESSMENT OF AWARENESS LEVEL OF OWN DISEASE IN PATIENTS WITH STABLE ARTERIAL HYPERTENSION

    Directory of Open Access Journals (Sweden)

    G. F. Andreeva

    2005-01-01

    Full Text Available Arterial hypertension (AH is the most frequent risk factor of cardiovascular diseases and related mortality in all developed countries. Altough therapy with antihypertensive drugs significantly reduces this risk, patients with stable mild hypertension have poor compliance with the treatment. The reasons and levels of inadequacy of antihypertensive therapy in this group of patients are well-known.Aim. To evaluate the awareness level of own disease, adequacy of therapy only in those patients with stable mild arterial hypertension, who are complied with recommendations of physicians concerning AH treatment and changing of mode of life. It was also planned to reveal possible grounds for inadequate secondary prevention of cardiovascular disease.Materials and methods. 76 patiens with stable mild arterial hypertension were included into study. They didn’t have any serious concomitant diseases and were complied with the recommendations of physicians concerning secondary prevention of cardiovascular disease. Questionnaire of State Research Center for Preventive Medicine “Assessment of awareness level of own disease in patients with stable arterial hypertension” was used in the study.Results. It was revealed, that the majority of patients, invoved in the study, were nonsmokers and regularly took antihypertensive drugs. 70% of questioned patients reached the target arterial blood pressure levels, while patients with arterial hypertension in general Russia population received regular and efficient treatment in less than 30-20%. Drugs treatment of questioned patients almost didn’t differ from that, which received patients in out-patient clinics of Moscow: in both cases ACE inhibitors were preferred. Only 29% of questioned patients knew their lipid levels in blood and none of the patients took drugs, reducing levels of lipids in blood. Half of the patients, that took part in our study, had increased level of body mass index.Conclusions. Inadequate

  6. A computational analysis of the long-term regulation of arterial pressure.

    Science.gov (United States)

    Beard, Daniel A; Pettersen, Klas H; Carlson, Brian E; Omholt, Stig W; Bugenhagen, Scott M

    2013-01-01

    The asserted dominant role of the kidneys in the chronic regulation of blood pressure and in the etiology of hypertension has been debated since the 1970s. At the center of the theory is the observation that the acute relationships between arterial pressure and urine production-the acute pressure-diuresis and pressure-natriuresis curves-physiologically adapt to perturbations in pressure and/or changes in the rate of salt and volume intake. These adaptations, modulated by various interacting neurohumoral mechanisms, result in chronic relationships between water and salt excretion and pressure that are much steeper than the acute relationships. While the view that renal function is the dominant controller of arterial pressure has been supported by computer models of the cardiovascular system known as the "Guyton-Coleman model", no unambiguous description of a computer model capturing chronic adaptation of acute renal function in blood pressure control has been presented. Here, such a model is developed with the goals of: 1. representing the relevant mechanisms in an identifiable mathematical model; 2. identifying model parameters using appropriate data; 3. validating model predictions in comparison to data; and 4. probing hypotheses regarding the long-term control of arterial pressure and the etiology of primary hypertension. The developed model reveals: long-term control of arterial blood pressure is primarily through the baroreflex arc and the renin-angiotensin system; and arterial stiffening provides a sufficient explanation for the etiology of primary hypertension associated with ageing. Furthermore, the model provides the first consistent explanation of the physiological response to chronic stimulation of the baroreflex.

  7. Effect of treatment temperature on collagen structures of the decellularized carotid artery using high hydrostatic pressure.

    Science.gov (United States)

    Negishi, Jun; Funamoto, Seiichi; Kimura, Tsuyoshi; Nam, Kwangoo; Higami, Tetsuya; Kishida, Akio

    2011-09-01

    Decellularized tissues have attracted a great deal of attention as regenerating transplantation materials. A decellularizing method based on high hydrostatic pressure (HHP) has been developed, and the preparation of many types of decellularized tissues has been investigated, including aorta, cornea, and dermis. The preparation of a small-diameter vascular graft was studied using a carotid artery from the viewpoint of collagen denaturation and leakage. After HHP, the carotid artery was washed at two washing temperatures (37 and 4°C). Histological evaluation, collagen content measurement and circular dichroism (CD) measurement indicated that the washing temperatures clearly affected the collagen structure of the decellularized carotid artery. The amount of collagen decreased in the carotid artery decellularized by HHP washed at 37°C (HHP/37°C). On the other hand, the amount and structure of collagen were preserved in the carotid artery washed at 4°C after HHP (HHP/4°C). In rat carotid artery syngeneic transplantation, the HHP/37°C decellularized carotid artery occluded after 2 weeks, but the HHP/4°C decellularized one did not. These results indicate that collagen denaturation and leakage of the decellularized carotid artery affect the in vivo performance of the carotid artery.

  8. Comparison of noninvasive blood pressure measurement techniques via the coccygeal artery in anesthetized cheetahs (Acinonyx jubatus).

    Science.gov (United States)

    Sadler, Ryan A; Hall, Natalie H; Kass, Philip H; Citino, Scott B

    2013-12-01

    Two indirect blood pressure measurement techniques, Doppler (DOP) sphygmomanometry and oscillometry, applied at the ventral coccygeal artery were compared with simultaneous direct blood pressure measurements at the dorsal pedal artery in 10 anesthetized, captive cheetahs (Acinonyx jubatus). The DOP method was moderately accurate, with relatively little bias (mean difference 3.8 mmHg) and 88.6% of the DOP systolic arterial pressure measurements being within 10 mmHg of the direct systolic arterial measurement. With the oscillometric (OM) method, 89.2% of the mean arterial pressure measurements were within 10 mmHg of the direct measurement and had the least bias (mean difference 2.3 mmHg), 80.7% of the systolic measurements were within 10 mmHg of the direct measurement and had the second least bias (mean difference 2.3 mmHg), and 59% of the diastolic measurements were within 10 mmHg of the direct measurement and had significant bias (mean difference 7.3 mmHg). However, DOP showed relatively poor precision (SD 11.2 mmHg) compared with OM systolic (SD 8.0 mmHg), diastolic (SD 8.6 mmHg), and mean (SD 5.7 mmHg). Both techniques showed a linear relationship with the direct technique measurements over a wide range of blood pressures. The DOP method tended to underestimate systolic measurements below 160 mmHg and overestimate systolic measurements above 160 mmHg. The OM method tended to underestimate mean pressures below 160 mm Hg, overestimate mean pressures above 160 mmHg, underestimate systolic pressures below 170 mmHg, overestimate systolic pressures above 170 mmHg, and underestimate diastolic pressures throughout the measured blood pressure range. Indirect blood pressure measurement using the ventral coccygeal artery, particularly when using an OM device for mean and systolic arterial pressure, may be useful in the clinical assessment of cheetahs when monitoring trends over time, but caution should be taken when interpreting individual values.

  9. A reusable perforator-preserving gluteal artery-based rotation fasciocutaneous flap for pressure sore reconstruction.

    Science.gov (United States)

    Lin, Pao-Yuan; Kuo, Yur-Ren; Tsai, Yun-Ta

    2012-03-01

    Perforator-based fasciocutaneous flaps for reconstructing pressure sores can achieve good functional results with acceptable donor site complications in the short-term. Recurrence is a difficult issue and a major concern in plastic surgery. In this study, we introduce a reusable perforator-preserving gluteal artery-based rotation flap for reconstruction of pressure sores, which can be also elevated from the same incision to accommodate pressure sore recurrence. The study included 23 men and 13 women with a mean age of 59.3 (range 24-89) years. There were 24 sacral ulcers, 11 ischial ulcers, and one trochanteric ulcer. The defects ranged in size from 4 × 3 to 12 × 10 cm(2) . Thirty-six consecutive pressure sore patients underwent gluteal artery-based rotation flap reconstruction. An inferior gluteal artery-based rotation fasciocutaneous flap was raised, and the superior gluteal artery perforator was preserved in sacral sores; alternatively, a superior gluteal artery-based rotation fasciocutaneous flap was elevated, and the inferior gluteal artery perforator was identified and dissected in ischial ulcers. The mean follow-up was 20.8 (range 0-30) months in this study. Complications included four cases of tip necrosis, three wound dehiscences, two recurrences reusing the same flap for pressure sore reconstruction, one seroma, and one patient who died on the fourth postoperative day. The complication rate was 20.8% for sacral ulcers, 54.5% for ischial wounds, and none for trochanteric ulcer. After secondary repair and reconstruction of the compromised wounds, all of the wounds healed uneventfully. The perforator-preserving gluteal artery-based rotation fasciocutaneous flap is a reliable, reusable flap that provides rich vascularity facilitating wound healing and accommodating the difficulties of pressure sore reconstruction. Copyright © 2011 Wiley Periodicals, Inc.

  10. Serum lipoprotein (a) levels in patients with arterial hypertension.

    Science.gov (United States)

    Serban, Corina; Nicola, T; Mateescu, Rodica; Noveanu, Lavinia; Susan, Lelia; Pacurari, Alina; Caraba, A; Romoşan, I; Cristescu, A

    2010-01-01

    Lp(a) is capable of deleteriously altering the balance between the procoagulant and anticoagulant, proinflammatory and anti-inflammatory, and vasorelaxing and vasoconstricting properties of the endothelium. The purpose of this study was to investigate the serum concentration of Lp(a) and the main parameters of lipid profile in three groups of subjects: a control group that included 16 healthy subjects, 20 patients with arterial hypertension and dyslipidemia and 20 patients with arterial hypertension without dyslipidemia. Using B-mode ultrasonography, we evaluated carotid intima-media thickness (IMT) and flow mediated vasodilation (FMD) on brachial artery. We found significant higher Lp(a) concentrations in hypertensive patients with dislipidemia (70 +/- 55.95 mg/dL, p dislipidemia (69 +/- 52.33 mg/dL, p dislipidemia we found a strong negative correlation between Lp(a) and carotid IMT (R2 = -0.75, p < 0.001) and a moderate negative correlation between Lp(a) and FMD (R2 = -0.38, p < 0.001). Lp(a) level wasn't correlated with the main parameters of lipid profile. These results indicated that serum Lp(a) values could play an important role in essential hypertension pathogenesis and could be considered as an individual risk factor in hypertensive patients.

  11. Changes in the retrobulbar arterial circulation after decrease of the elevated intraocular pressure in men and women with primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2013-01-01

    Full Text Available Introduction. An altered perfusion of the optic nerve head has been proposed as a pathogenic factor of glaucoma. Objective. The aim of this study was to evaluate the changes of the hemodynamic parameters in the retrobulbar arterial circulation after decrease of the elevated intraocular pressure (IOP in women and men with primary open angle glaucoma. Methods. The study included 60 patients (33 males and 27 females older than 50 years, with diagnosed and treated primary open angle glaucoma (77 eyes of 39 patients had increased IOP, >25 mm Hg. They were examined at the Clinic of Eye Diseases (complete ophthalmologic exam and Clinic of Neurology, Clinical Center of Serbia, Belgrade, from December 2009 to December 2010. Imaging of hemodynamic parameters of three retrobulbar arterial vessels: ophthalmic, central retinal and posterior ciliary arteries with color Doppler was performed. Results. Among women, hemodynamic arterial parameter of the peak-systolic velocity was increased in the central retinal artery and decreased in the ophthalmic artery and posterior ciliary arteries; end- diastolic velocity was increased in all three retrobulbar vascular levels; Pourcelot resistivity index was increased, but pulsatility index was decreased in all three vessels. Among men, peak-systolic velocity, end-diastolic velocity and pulsatility index were decreased in all three vessels; resistivity index was increased in the ophthalmic artery, but decreased in the central retinal artery and posterior ciliary arteries. There was a significant change of the ophthalmic artery pulsatility index in women, and the end-diastolic velocity of the ophthalmic artery in men. Conclusion. There was a difference of the retrobulbar arterial circulation between women and men with primary open angle glaucoma after decrease of the elevated intraocular pressure. The role of vascular factors in the supply of the optic disc neuroretinal rim is important.

  12. Obese children and adolescents have elevated nighttime blood pressure independent of insulin resistance and arterial stiffness

    DEFF Research Database (Denmark)

    Hvidt, Kristian N; Olsen, Michael H; Holm, Jens-Christian

    2014-01-01

    BACKGROUND: Insulin resistance has been related to elevated blood pressure (BP) in obese children and may adversely affect the vasculature by arterial stiffening. The objective was to investigate whether daytime and nighttime BP were elevated and related to insulin resistance and arterial stiffness...... in obese children and adolescents. METHODS: Ninety-two obese patients aged 10-18 years were compared with 49 healthy control individuals. Insulin resistance was measured as the homeostatic assessment model (HOMA), and arterial stiffness was measured as carotid-femoral pulse wave velocity (cfPWV). RESULTS...... analyses, the higher nighttime BP in the obese group was independent of logHOMA and cfPWV. CONCLUSIONS: Obese children had a higher nighttime BP when compared with the control group independently of insulin resistance and arterial stiffness. No relationship was found between insulin resistance and arterial...

  13. Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

    Directory of Open Access Journals (Sweden)

    Jong-Gu Choi

    2011-01-01

    Full Text Available To measure precise blood pressure (BP and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.

  14. Arterial dysfunction but maintained systemic blood pressure in cavin-1-deficient mice.

    Directory of Open Access Journals (Sweden)

    Karl Swärd

    Full Text Available Caveolae are omega-shaped plasma membrane micro-domains that are abundant in cells of the vascular system. Formation of caveolae depends on caveolin-1 and cavin-1 and lack of either protein leads to loss of caveolae. Mice with caveolin-1 deficiency have dysfunctional blood vessels, but whether absence of cavin-1 similarly leads to vascular dysfunction is not known. Here we addressed this hypothesis using small mesenteric arteries from cavin-1-deficient mice. Cavin-1-reporter staining was intense in mesenteric arteries, brain arterioles and elsewhere in the vascular system, with positive staining of both endothelial and smooth muscle cells. Arterial expression of cavin-1, -2 and -3 was reduced in knockout (KO arteries as was expression of caveolin-1, -2 and -3. Caveolae were absent in the endothelial and smooth muscle layers of small mesenteric arteries as determined by electron microscopy. Arginase, a negative regulator of nitric oxide production, was elevated in cavin-1 deficient arteries as was contraction in response to the α1-adrenergic agonist cirazoline. Detailed assessment of vascular dimensions revealed increased media thickness and reduced distensibility, arguing that enhanced contraction was due to increased muscle mass. Contrasting with increased α1-adrenergic contraction, myogenic tone was essentially absent and this appeared to be due in part to increased nitric oxide production. Vasomotion was less frequent in the knock-out vessels. In keeping with the opposing influences on arterial resistance of increased agonist-induced contractility and reduced myogenic tone, arterial blood pressure was unchanged in vivo. We conclude that deficiency of cavin-1 affects the function of small arteries, but that opposing influences on arterial resistance balance each other such that systemic blood pressure in unstressed mice is well maintained.

  15. Role of pressor mechanisms from the NTS and CVLM in control of arterial pressure.

    Science.gov (United States)

    Moreira, Thiago Santos; Sato, Monica Akemi; Takakura, Ana Carolina Thomaz; Menani, José Vanderlei; Colombari, Eduardo

    2005-11-01

    In the present study, we investigated the effects of inhibition of the caudal ventrolateral medulla (CVLM) with the GABA(A) agonist muscimol combined with the blockade of glutamatergic mechanism in the nucleus of the solitary tract (NTS) with kynurenic acid (kyn) on mean arterial pressure (MAP), heart rate (HR), and regional vascular resistances. In male Holtzman rats anesthetized intravenously with urethane/chloralose, bilateral injections of muscimol (120 pmol) into the CVLM or bilateral injections of kyn (2.7 nmol) into the NTS alone increased MAP to 186 +/- 11 and to 142 +/- 6 mmHg, respectively, vs. control: 105 +/- 4 mmHg; HR to 407 +/- 15 and to 412 +/- 18 beats per minute (bpm), respectively, vs. control: 352 +/- 12 bpm; and renal, mesenteric and hindquarter vascular resistances. However, in rats with the CVLM bilaterally blocked by muscimol, additional injections of kyn into the NTS reduced MAP to 88 +/- 5 mmHg and mesenteric and hindquarter vascular resistances below control baseline levels. Moreover, in rats with the glutamatergic mechanisms of the NTS blocked by bilateral injections of kyn, additional injections of muscimol into the CVLM also reduced MAP to 92 +/- 2 mmHg and mesenteric and hindquarter vascular resistances below control baseline levels. Simultaneous blockade of NTS and CVLM did not modify the increase in HR but also abolished the increase in renal vascular resistance produced by each treatment alone. The results suggest that important pressor mechanisms arise from the NTS and CVLM to control vascular resistance and arterial pressure under the conditions of the present study.

  16. Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational study.

    Science.gov (United States)

    Romagnoli, Stefano; Ricci, Zaccaria; Quattrone, Diego; Tofani, Lorenzo; Tujjar, Omar; Villa, Gianluca; Romano, Salvatore M; De Gaudio, A Raffaele

    2014-11-30

    Critically ill patients and patients undergoing high-risk and major surgery, are instrumented with intra-arterial catheters and invasive blood pressure is considered the "gold standard" for arterial pressure monitoring. Nonetheless, artifacts due to inappropriate dynamic response of the fluid-filled monitoring systems may lead to clinically relevant differences between actual and displayed pressure values. We sought to analyze the incidence and causes of resonance/underdamping phenomena in patients undergoing major vascular and cardiac surgery. Arterial pressures were measured invasively and, according to the fast-flush Gardner's test, each patient was attributed to one of two groups depending on the presence (R-group) or absence (NR-group) of resonance/underdamping. Invasive pressure values were then compared with the non-invasive ones. A total of 11,610 pulses and 1,200 non-invasive blood pressure measurements were analyzed in 300 patients. Ninety-two out of 300 (30.7%) underdamping/resonance arterial signals were found. In these cases (R-group) systolic invasive blood pressure (IBP) average overestimation of non-invasive blood pressure (NIBP) was 28.5 (15.9) mmHg (P pressure in the R-group was -2.2 (10.6) mmHg and, in the NR-group -1.1 (5.8) mmHg. The mean arterial pressure difference was 7.4 (11.2) mmHg in the R-group and 2.3 (6.4) mmHg in the NR-group. A multivariate logistic regression identified five parameters independently associated with underdamping/resonance: polydistrectual arteriopathy (P = 0.0023; OR = 2.82), history of arterial hypertension (P = 0.0214; OR = 2.09), chronic obstructive pulmonary disease (P = 0.198; OR = 2.61), arterial catheter diameter (20 vs. 18 gauge) (P pressure-time ratio, showed an optimum selected cut-off point of 1.67 mmHg/msec with a specificity of 97% (95% CI: 95.13 to 99.47%) and a sensitivity of 77% (95% CI: 67.25 to 85.28%) and an area under the ROC curve by extended trapezoidal rule of 0.88. Physicians should be aware

  17. Mean arterial pressure change associated with cerebral blood flow in healthy older adults.

    Science.gov (United States)

    Deverdun, Jeremy; Akbaraly, Tasnime N; Charroud, Celine; Abdennour, Meriem; Brickman, Adam M; Chemouny, Stephane; Steffener, Jason; Portet, Florence; Bonafe, Alain; Stern, Yaakov; Ritchie, Karen; Molino, François; Le Bars, Emmanuelle; Menjot de Champfleur, Nicolas

    2016-10-01

    We investigate over a 12-year period the association between regional cerebral blood flow (CBF) and cardiovascular risk factors in a prospective cohort of healthy older adults (81.96 ± 3.82 year-old) from the Cognitive REServe and Clinical ENDOphenotype (CRESCENDO) study. Cardiovascular risk factors were measured over 12 years, and gray matter CBF was measured at the end of the study from high-resolution magnetic resonance imaging using arterial spin labeling. The association between cardiovascular risk factors, their long-term change, and CBF was assessed using multivariate linear regression models. Women were observed to have higher CBF than men (p < 0.05). Increased mean arterial pressure (MAP) over the 12-year period was correlated with a low cerebral blood flow (p < 0.05, R(2) = 0.21), whereas no association was detected between CBF and MAP at the time of imaging. High levels of glycemia tended to be associated with low cerebral blood flow values (p < 0.05). Age, alcohol consumption, smoking status, body mass index, history of cardiovascular disease, and hypertension were not associated with CBF. Our main result suggests that change in MAP is the most significant predictor of future CBF in older adults.

  18. Results of ambulatory arterial blood pressure monitoring in children with obesity

    Directory of Open Access Journals (Sweden)

    Faruk Öktem

    2010-12-01

    Full Text Available Objectives: The relationship between obesity and essential hypertension is well known. In this study, we aimed to evaluate ambulatory arterial blood pressure monitoring of obese and non-obese children who had similar demographic characteristics.Materials and methods: Seventy one children and adolescents (n=39 obesity, n=32 controls were studied. Blood pressure of the children were measured by 24 hour ambulatory blood pressure monitoring device.Results: Obese children had significantly higher mean blood pressure values (systolic 121.9±11.7 mmHg, diastolic 70.2±5.3 mmHg than control subjects (systolic 109.3±6.7 mmHg, diastolic 65.1±4.6 mmHg, p0.05. Blood pressure load was found to be increased in obese children compared to the controls (%13.6±12.9 and %2.6±3.4, respectively; p<0.05. Serum total cholesterol and LDL-cholesterol levels of obese children (181.1±33.4 and 131.1±23.1mg/dl were significantly higher than those of the controls (134.3±11.1 and 103.3±14.2 mg/dl, p<0.05.Conclusions: Obesity in children and adolescents should not be regarded as variations of normality, but as abnormality with an extremely high risk for the development of hypertension and hyperlipidemia in adulthood.

  19. Circadian rhythm of arterial blood pressure and albuminuria in diabetic nephropathy

    DEFF Research Database (Denmark)

    1996-01-01

    was about the same in the three groups. Our study indicated an association between blood pressure and albuminuria, but the mechanisms involved in the reduction of albuminuria from day to night was not unraveled. A relative lack of sympathetic withdrawal during sleep seems to be an important feature......The aim of our study was to evaluate the diurnal relationship between arterial blood pressure and albuminuria, and some potential mechanisms responsible for impaired nocturnal blood pressure reduction (non-dippers, groups I and II) in diabetic nephropathy (DN). Twenty-four-hour ambulatory blood...... pressure, heart rate (HR) variation (autonomic nervous function) and extracellular fluid volume (ECV) were measured, and urine samples were collected three times during the corresponding day- and nighttimes in 47 insulin-dependent diabetic (IDDM) patients with DN. Mean arterial blood pressure (MABP) during...

  20. HISTOLOGICAL STUDY OF MEDIUM SIZED ARTERIES OF NECK IN RELATION WITH THEIR PULSE PRESSURE AND PULSATORY POWER

    Directory of Open Access Journals (Sweden)

    Prerana

    2014-11-01

    Full Text Available : INTRODUCTION: There are several studies on the microstructure of main arteries of the body but limited have been dealt with the neck arteries. It has been mentioned that the vascular pathologies like the thrombo-embolism, atherosclerosis and infarction are common in the branches of vertebral and internal carotid artery as compared to the branches of external carotid artery. OBJECTIVE: To study the histological structure of the 3 medium sized arteries of neck namely external carotid, internal carotid and vertebral artery, calculation of their mean pulse pressure and pulsatory power and to find any association between them if present. METHOD: Fresh samples of external carotid, internal carotid and vertebral artery each measuring 10mm in length were taken from five cadavers and prepared for histological examination under microscope using orcein and H&E stain. The mean pressure and pulsatory power of these arteries were calculated by taking the measurements such as wall thickness, lumen circumference, arterial wall area, and smooth muscle fibre density in tunica media in that arterial segment. RESULT: The pulsatory power of external carotid artery, internal carotid artery and vertebral artery is found to be 120, 273.3, 400 Joules /heart beat and the mean pressure is 17.1 mm Hg, 27.3 mm Hg and 33.3 mm Hg respectively. CONCLUSION: The thickness of tunica media of an artery is directly proportional to its pulsatory power. The mean pulse pressure, pulsatory power as well the number of smooth muscles fibres in tunica media are more in internal carotid artery and vertebral artery in comparison to external carotid artery. It may be a very important reason why vascular pathologies are less common in branches of external carotid as compare to internal carotid and vertebral artery.

  1. Circuit for detecting initial systole and dicrotic notch. [for monitoring arterial pressure

    Science.gov (United States)

    Gebben, V. D.; Webb, J. A., Jr. (Inventor)

    1974-01-01

    Circuitry is disclosed for processing an arterial pressure waveform to produce during any one cycle a pulse corresponding to the initial systole and a pulse corresponding to the dicrotic notch. In a first channel, an electrical analog of the arterial pressure waveform is filtered and then compared to the original waveform to produce an initial systole signal. In a second channel, the analog is differentiated, filtered, and fed through a gate controlled by pulses from the first channel to produce an electrical pulse corresponding to the dicrotic notch.

  2. Activity of the positive and negative reinforcement motivation systems and baseline arterial blood pressure in humans.

    Science.gov (United States)

    Aftanas, L I; Sidorova, P V; Pavlov, S V; Makhnev, V P; Korenek, V V; Reva, N V; Amstislavskaya, T G

    2008-10-01

    The aim of the present work was to identify possible associations between individual balances in the activity of the positive and negative reinforcement motivation systems using a method based on emotional modulation of the startle reaction (EMSR) by motivationally significant emotionally positive and negative contextual visual stimuli and measures of cardiovascular system activity. Studies were performed using healthy males (mean age 30.29 +/- 9.8 years) with normal and first-episode excessive increases in arterial blood pressure (systolic blood pressure to greater than 140 mmHg, diastolic to greater than 90 mmHg). Cluster analysis of EMSR data identified groups of individuals with different activity profiles for the positive and negative reinforcement systems. Groups of subjects with changes in the balance of activity towards a lower level of positive reinforcement system activity (smaller startle reflexes to positive contextual stimuli) or a higher level of negative reinforcement system activity (larger startle reactions to threatening contextual stimuli) showed significantly greater baseline SBP and DBP. The possible mechanisms of the modulatory influences of the balance of system activities on autonomic vascular regulatory processes are discussed.

  3. Comparison of noninvasive blood pressure monitoring with invasive arterial pressure monitoring in medical ICU patients with septic shock.

    Science.gov (United States)

    Riley, Leonard E; Chen, Guoqing John; Latham, Heath E

    2017-08-01

    In the critically ill, the insertion of peripheral arterial catheters to monitor hemodynamics is a low-risk procedure, but carries the potential for complications. This study was designed to compare invasive and noninvasive blood pressure measurements in patients with septic shock in a medical ICU. We carried out a prospective observational study of patients admitted with septic shock and a radially inserted peripheral arterial catheter in the medical ICU with 31 adult patients who underwent four pairs of simultaneous noninvasive and invasive blood pressure measurements (124 comparisons), with the invasive blood pressure taken as the gold standard. Agreements between invasive and noninvasive blood pressure methods were assessed using Bland-Altman analysis, and clinical significance was determined by the European Society of Hypertension criteria. In all patients, noninvasive systolic (P=0.0385), diastolic (Parterial pressures (Ppressure measurements did not correlate clinically according to the European Society of Hypertension criteria. In our patients admitted to the medical ICU with septic shock, noninvasive blood pressure monitoring did not clinically correlate with invasive blood pressure measurements.

  4. Association of thyroid function with arterial pressure in normotensive and hypertensive euthyroid individuals: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Saltiki Katerina

    2008-09-01

    Full Text Available Abstract Background Overt hypothyroidism has been associated with arterial hypertension and increased arterial stiffness. Results in euthyroid individuals have been conflicting. We investigated associations of thyroid function with systolic (SAP and diastolic (DAP arterial pressure in euthyroid subjects. Methods 311 euthyroid individuals (185 women, mean age 43.9 ± 9 without a history of diabetes attending a preventive medicine program were examined. Subjects receiving thyroxine (10.6% were excluded; 19.3% had hypertension, 43% had a family history for hypertension. TSH, fT4, thyroid autoantibodies, insulin, glucose were measured. The "fT4.TSH product", which has been suggested as a T4 resistance-index, was calculated. Results TSH range was 0.1–8, median 1.4 mU/L, fT4 range was 11.5–25.2 pmol/L, median 17.4. TSH and the "fT4.TSH product" were positively associated with DAP (p 2 mU/L (35.3% vs 21.3%, p = 0.045. Conclusion In euthyroid individuals the association of thyroid function with diastolic arterial pressure remains significant even when a stricter "normal range" for TSH levels is considered. The "freeT4.TSH" product appears to be an even stronger predictor of DAP, independently of HOMA insulin resistance index and obesity.

  5. Acute effects of supramaximal exercise on carotid artery compliance and pulse pressure in young men and women.

    Science.gov (United States)

    Rossow, Lindy; Fahs, Christopher A; Guerra, Myriam; Jae, Sae Young; Heffernan, Kevin S; Fernhall, Bo

    2010-11-01

    The purpose of this study was to determine the cumulative effects of repeated cycling sprints (Wingate tests) on carotid compliance and blood pressure (BP). Fourteen young, healthy men and women completed this study. Vascular and hemodynamic measurements were taken at rest, 5 min following a first Wingate test, 25 min following the first Wingate test, 5 min following a second Wingate test, and 25 min following the second Wingate test. At each time point, the measurements taken included brachial and carotid pulse pressure (PP), heart rate, carotid artery maximum and minimum diameters, and carotid compliance. Carotid BP was obtained with applanation tonometry. Carotid diameters were obtained using ultrasonography and compliance was calculated from carotid diameters and BP. Carotid and brachial PP increased significantly (P sprint, carotid arterial compliance decreased significantly more than 5 min following the first sprint (P sprint reduces carotid artery compliance immediately after exercise. Performance of a second identical cycling sprint further compounds this vascular change, reducing carotid artery compliance beyond levels seen following a single cycling sprint.

  6. Retrograde arterial leg blood flow during tilt-back from a head-up posture: importance of capacitive flows when arterial pressure changes.

    Science.gov (United States)

    Sheriff, Don D; Nådland, Inger Helene; Toska, Karin

    2010-03-01

    The windkessel function of the arterial system converts the intermittent action of the heart into more continuous microcirculatory blood flow during diastole via the return of elastic energy stored in the walls of the arteries during systole. Might the same phenomenon occur regionally within the arterial system during tilting owing to regional differences in local arterial pressure imposed by gravity? We sought to test the hypothesis that during tilt-back from a head-up posture, the return of stored elastic energy in leg arteries would work to slow, or perhaps transiently reverse, the flow of blood in the femoral artery. Femoral artery blood flow and arterial pressure were recorded during tilt back from a 30 degrees head-up posture to supine (approximately 0.5 G) in young, healthy subjects (n = 7 males and 3 females) before and during clonidine infusion. During control (no drug) conditions femoral artery blood flow ceased for an entire heart beat during tilt-back. During clonidine infusion femoral artery blood flow reversed for at least one entire heart beat during tilt-back, i.e., blood flow in the retrograde direction in the femoral artery from the leg into the abdomen. Thus substantial capacitive effects of tilting on leg blood flow occur in humans during mild changes in posture.

  7. Use of paravascular admittance waveforms to monitor relative change in arterial blood pressure

    Science.gov (United States)

    Zielinski, Todd M.; Hettrick, Doug; Cho, Yong

    2010-04-01

    Non-invasive methods to monitor ambulatory blood pressure often have limitations that can affect measurement accuracy and patient adherence [1]. Minimally invasive measurement of a relative blood pressure surrogate with an implantable device may provide a useful chronic diagnostic and monitoring tool. We assessed a technique that uses electrocardiogram and paravascular admittance waveform morphology analysis to one, measure a time duration (vascular tone index, VTI in milliseconds) change from the electrocardiogram R-wave to admittance waveform peak and two, measure the admittance waveform minimum, maximum and magnitude as indicators of change in arterial compliance/distensibility or pulse pressure secondary to change in afterload. Methods: Five anesthetized domestic pigs (32 ± 4.2 kg) were used to study the effects of phenylephrine (1-5 ug/kg/min) on femoral artery pressure and admittance waveform morphology measured with a quadrapolar electrode array catheter placed next to the femoral artery to assess the relative change in arterial compliance due to change in peripheral vascular tone. Results: Statistical difference was observed (p blood pressure may be suitable for implantable devices to detect progression of cardiovascular disease such as hypertension.

  8. Energy harvesting from arterial blood pressure for powering embedded brain sensors

    Science.gov (United States)

    Nanda, Aditya; Karami, M. Amin

    2016-04-01

    This paper investigates energy harvesting from arterial blood pressure via the piezoelectric effect by using a novel streaked cylinder geometry for the purpose of powering embedded micro-sensors in the brain. Initially, we look at the energy harvested by a piezoelectric cylinder placed inside an artery acted upon by blood pressure. Such an arrangement would be tantamount to constructing a stent out of piezoelectric materials. A stent is a cylinder placed in veins and arteries to prevent obstruction in blood flow. The governing equations of a conductor coated piezoelectric cylinder are obtained using Hamilton's principle. Pressure acting in arteries is radially directed and this is used to simplify the modal analysis and obtain the transfer function relating pressure to the induced voltage across the surface of the harvester. The power harvested by the cylindrical harvester is obtained for different shunt resistances. Radially directed pressure occurs elsewhere and we also look at harvesting energy from oil flow in pipelines. Although the energy harvested by the cylindrical energy harvester is significant at resonance, the natural frequency of the system is found to be very high. To decrease the natural frequency, we propose a novel streaked stent design by cutting it along the length, transforming it to a curved plate and decreasing the natural frequency. The governing equations corresponding to the new geometry are derived using Hamilton's principle and modal analysis is used to obtain the transfer function.

  9. Evaluation of restenosis, renal function and blood pressure after the renal artery stenting in patients with atherosclerosis renovascular disease

    Institute of Scientific and Technical Information of China (English)

    王焱

    2006-01-01

    Objective To evaluate the restenosis, renal function and blood pressure after renal artery stenting in patients with atherosclerosis renovascular disease. Methods Percutaneous renal artery stent (PTRAS) was performed in 135 patients with single or bilateral renal artery stenosis (≥70%). Clinical data of above patients were studied during follow-up period. Results A total of 147

  10. Strophanthus hispidus attenuates the Ischemia-Reperfusion induced myocardial Infarction and reduces mean arterial pressure in renal artery occlusion

    Directory of Open Access Journals (Sweden)

    Rohit Gundamaraju

    2014-01-01

    Full Text Available Background: The myocardium is generally injured in the case of reperfusion injury and arterial damage is caused by hypertension. In reference to these statements, the present study was focused. Cardiac glycosides were said to have protective effects against myocardial infarction and hypertension. Strophanthus hispidus was thus incorporated in the study. Objective: The prime objective of the study was to investigate the protective effects of Strophanthus hispidus against ischemia-reperfusion myocardial Infarction and renal artery occluded hypertension in rats. Materials and Methods: The animal model adopted was surgically-induced myocardial ischemia, performed by means of left anterior descending coronary artery occlusion (LAD for 30 min followed by reperfusion for another 4 h. Infarct size was assessed by using the staining agent TTC (2,3,5-triphenyl tetrazolium chloride. Hypertension was induced by clamping the renal artery with renal bulldog clamp for 4 h. Results: The study was fruitful by the effect of Strophanthus hispidus on infarction size, which got reduced to 27.2 ± 0.5and 20.0 ± 0.2 by 500 mg/Kg and 1000 mg/Kg ethanolic extracts which was remarkably significant when compared with that of the control group 52.8 ± 4.6. The plant extract did reduce heart rate at various time intervals. There was also a protective effect in the case of mean arterial blood pressure were the 500 mg/Kg and 1000 mg/Kg of the plant extract did reduce the hypertension after 60 minutes was 60.0 ± 4.80 and 50.50 ± 6.80. Conclusion: The results suggest that 500 mg/Kg and 100 mg/Kg ethanolic extract of Strophanthus hispidus was found to possess significant cardiac protective and anti-hypertensive activity.

  11. Relationship between pulmonary artery volumes at computed tomography and pulmonary artery pressures in patients with- and without pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Froelich, Jens J. [Department of Radiology, Philipps-University Hospital, Baldingerstrasse, 35043 Marburg (Germany)], E-mail: jens.froelich@klinikum-hef.de; Koenig, Helmut [Department of Radiology, Philipps-University Hospital, Baldingerstrasse, 35043 Marburg (Germany)], E-mail: helmut.koenig@siemens.com; Knaak, Lennard [Department of Medicine, Philipps-University Hospital, Baldingerstrasse, 35043 Marburg (Germany)], E-mail: froehlic@staff.uni-marburg.de; Krass, Stefan [MeVis Research, Universitaetsallee 29, 28359 Bremen (Germany)], E-mail: krass@mevis.de; Klose, Klaus J. [Department of Radiology, Philipps-University Hospital, Baldingerstrasse, 35043 Marburg (Germany)], E-mail: klose@med.uni-marburg.de

    2008-09-15

    Objectives: This study was designed to determine the relationship between pulmonary artery (PA) volumes at computed tomography (CT) and PA pressures at right-sided heart catheterization in patients with and without pulmonary hypertension (PAH) to develop a noninvasive CT method of PA pressure quantification. Materials and methods: Sixteen patients with chronic sleep apnea syndrome underwent contrast enhanced helical CT (slice thickness 3 mm; pitch 2; increment 2 mm) at inspiration. Eight patients had PAH while cardiopulmonary disease has been excluded in eight other patients. Vascular volumes were determined using a 3D technique (threshold seeded vascular tracing algorithm; thresholds -600 H [lower] and 3000 H [upper]). Right-sided heart catheterization measurements were available for linear regression analysis of PA volumes and pressures. Results: Correlation between PA pressures and volumes (normalized for BMI), was high in both groups (without PAH: r = .85; with PAH .90, Pearson). Compared to elevated PA pressures in patients with pulmonary hypertension (p < .005), PA volumes also were significantly increased (p < .05) among the groups. Conclusions: High correlation was found between PA volumes and mean PA pressures in patients with- and without PAH. Significant differences in PA volumes at CT-volumetry may admit non-invasive determination of pulmonary hypertension.

  12. Blood Pressure Level Amongst Lactovegetarian And Non-Vegetarian Males

    Directory of Open Access Journals (Sweden)

    Jain B K

    1999-01-01

    Full Text Available Research Question: Is the relative risk for the development of hypertension more among non vegetarians than lacto vegetarians? Objectives: To compare the arterial blood pressure between lacto vegetarian and non-vegetarian males of 30 years and above. Design: Cross sectional study. Setting: In two different areas of walled city of Delhi. Study Variables: Blood pressure. Statistical analysis: Quetelet Index, t-test, z-test, x2-test, Relative risk

  13. Circulating ghrelin was negatively correlated with pulmonary arterial pressure in atrial septal defect patients

    Institute of Scientific and Technical Information of China (English)

    LI Zhao-feng; ZHOU Da-xin; PAN Wen-zhi; ZHANG Lei; GE Jun-bo

    2013-01-01

    Background Ghrelin was found to attenuate the magnitude of pulmonary arterial hypertension and pulmonary vascular remodeling in rats.The objective of this study was to explore the fasting plasma ghrelin level and the relationships between ghrelin and pulmonary arterial pressure (PAP) in atrial septal defect (ASD) patients with pulmonary arterial hypertension (PAH).Methods Fasting plasma ghrelin,obestatin,and insulin levels were measured by enzyme linked immunosorbent assay (ELISA) method in ASD patients with or without PAH according to the manufacturer's instructions.Insulin resistance was calculated by the homeostasis model of assessment for insulin resistance (HOMA-IR) approach,calculated as fasting insulin (microunits/ml)× fasting blood glucose (mmol/L)/22.5.Comparisons between the parameters of patients with PAH and those of patients with normal PAP were performed with an unpaired Student's t test.The relationships between ghrelin and various clinical parameters were examined by bivariate correlations and multiple regression analysis.Results We found that the fasting plasma ghrelin level and the ratio of ghrelin to obestatin were significantly lower in the PAH group compared with the control group ((582.4±12.8) pg/ml vs.(1045.2±95.5) pg/ml,P <0.05 and 30.5±4.9 vs.70.0±9.7,P <0.01).The fasting plasma obestatin level was higher in the PAH group compared with the control group,but the difference between them was not significant ((23.2±3.1) pg/ml vs.(16.3±1.6) pg/ml,P >0.05).In a multiple regression model analysis,only mean PAP was an independent predictor of ghrelin and the ratio of ghrelin to obestatin (standardized coefficient=0.737,P <0.001 and standardized coefficient=-0.588,P=0.006,respectively).Conclusion Ghrelin is negatively correlated with mean PAP and this suggests that circulating ghrelin might predict the severity of pulmonary hypertension in ASD patients with PAH.

  14. Arterial pulse pressure amplification described by means of a nonlinear wave model: characterization of human aging

    Science.gov (United States)

    Alfonso, M.; Cymberknop, L.; Armentano, R.; Pessana, F.; Wray, S.; Legnani, W.

    2016-04-01

    The representation of blood pressure pulse as a combination of solitons captures many of the phenomena observed during its propagation along the systemic circulation. The aim of this work is to analyze the applicability of a compartmental model for propagation regarding the pressure pulse amplification associated with arterial aging. The model was applied to blood pressure waveforms that were synthesized using solitons, and then validated by waveforms obtained from individuals from differentiated age groups. Morphological changes were verified in the blood pressure waveform as a consequence of the aging process (i.e. due to the increase in arterial stiffness). These changes are the result of both a nonlinear interaction and the phenomena present in the propagation of nonlinear mechanic waves.

  15. Children and Adolescent Obesity Associates with Pressure-Dependent and Age-Related Increase in Carotid and Femoral Arteries’ Stiffness and Not in Brachial Artery, Indicative of Nonintrinsic Arterial Wall Alteration

    Directory of Open Access Journals (Sweden)

    Victoria García-Espinosa

    2016-01-01

    Full Text Available Aim. To analyze if childhood obesity associates with changes in elastic, transitional, and/or muscular arteries’ stiffness. Methods. 221 subjects (4–15 years, 92 females were assigned to normal weight (NW, n=137 or obesity (OB, n=84 groups, considering their body mass index z-score. Age groups were defined: 4–8; 8–12; 12–15 years old. Carotid, femoral, and brachial artery local stiffness was determined through systodiastolic pressure-diameter and stress-strain relationships. To this end, arterial diameter and peripheral and aortic blood pressure (BP levels and waveforms were recorded. Carotid-femoral, femoropedal, and carotid-radial pulse wave velocities were determined to evaluate aortic, lower-limb, and upper-limb regional arterial stiffness, respectively. Correlation analysis between stiffness parameters and BP was done. Results. Compared to NW, OB subjects showed higher peripheral and central BP and carotid and femoral stiffness, reaching statistical significance in subjects aged 12 and older. Arterial stiffness differences disappeared when levels were normalized for BP. There were no differences in intrinsic arterial wall stiffness (elastic modulus, BP stiffness relationships, and regional stiffness parameters. Conclusion. OB associates with BP-dependent and age-related increase in carotid and femoral (but not brachial stiffness. Stiffness changes would not be explained by intrinsic arterial wall alterations but could be associated with the higher BP levels observed in obese children.

  16. Low level termination of external carotid artery and its clinical significance: A case report

    Directory of Open Access Journals (Sweden)

    Surekha Devadasa Shetty

    2015-09-01

    Full Text Available The external carotid arterial system is a complex vascular system providing nourishment to the territorial areas of the head and neck. The branches of the external carotid artery are the key landmarks for adequate exposure and appropriate placement of cross-clamps on the carotid arteries during carotid endarterectomy. Knowledge of anatomical variation of the external carotid artery is important in head and neck surgeries. Variations in the branching pattern of the external carotid artery are well known and documented. We report a rare case of low-level termination of the external carotid artery. It terminated by dividing into maxillary and superficial temporal arteries deep into the posterior belly of the digastric muscle, one inch below the angle of the mandible. The occipital and posterior auricular arteries arose from a common trunk given off by the external carotid artery. [Arch Clin Exp Surg 2015; 4(3.000: 160-163

  17. The mechanical properties of the systemic and pulmonary arteries of Python regius correlate with blood pressures.

    Science.gov (United States)

    van Soldt, Benjamin J; Danielsen, Carl Christian; Wang, Tobias

    2015-12-01

    Pythons are unique amongst snakes in having different pressures in the aortas and pulmonary arteries because of intraventricular pressure separation. In this study, we investigate whether this correlates with different blood vessel strength in the ball python Python regius. We excised segments from the left, right, and dorsal aortas, and from the two pulmonary arteries. These were subjected to tensile testing. We show that the aortic vessel wall is significantly stronger than the pulmonary artery wall in P. regius. Gross morphological characteristics (vessel wall thickness and correlated absolute amount of collagen content) are likely the most influential factors. Collagen fiber thickness and orientation are likely to have an effect, though the effect of collagen fiber type and cross-links between fibers will need further study.

  18. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Cary, Theodore W.; Sultan, Laith R.; Sehgal, Chandra M., E-mail: sehgalc@uphs.upenn.edu [Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Reamer, Courtney B.; Mohler, Emile R. [Department of Medicine, Division of Cardiovascular Medicine, Section of Vascular Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2014-02-15

    Purpose: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Methods: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. Results: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. Conclusions: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.

  19. 冠心病合并高血压患者血压控制程度对动脉弹性功能的影响%The impact of blood pressure level on arterial elasticity in patients with coronary heart disease and hypertension

    Institute of Scientific and Technical Information of China (English)

    杨文; 王鸿懿; 孙宁玲

    2013-01-01

    目的 探讨冠心病合并高血压患者血压控制程度对动脉弹性功能的影响.方法 选择经过冠状动脉造影证实的冠心病合并高血压患者46例,全部患者均经过降压药物治疗.根据血压水平将患者分为2组,其中23例为血压控制不良组(收缩压≥140 mm Hg或舒张压≥90mmHg),另23例为血压控制良好组(收缩压< 140 mm Hg且舒张压<90 mm Hg)作为配对(1∶1).对2组患者血压、血管弹性功能[颈动脉-股动脉脉搏波速度(cfPWV),系统血管顺应性(SVC)、肱动脉扩张性(BAD)、系统血管阻力(SVR)]进行测定和分析.结果 (1)在血压控制良好组cfPWV(m/s)明显低于控制不良组(10.38±1.73比12.83±3.13,P<0.01).(2)血压控制良好组的SVC(ml/mm Hg)、BAD(%/mm Hg)与血压控制不良组相比增高(1.16±0.23比0.94±0.17,6.01±0.98比4.63±0.71,均为P<0.01).(3)cfPWV与年龄、收缩压、脉压正相关,相关系数r分别为0.374、0.416、0.507.多元线性逐步回归分析显示,cfPWV=4.796+0.099×脉压,即cfPWV与脉压成线性关系,提示收缩压及脉压增大加重患者的大动脉功能减退.结论 冠心病合并高血压患者存在血管弹性功能异常,并与血压控制不良直接相关.血压控制良好的患者SVC、BAD、cfPWV均有改善,冠心病合并高血压患者需要良好的血压控制.%Objective To explore the relationship of blood pressure level with the arterial elasticity in patients suffered from essential hypertension and coronary heart disease.Methods Fourty-six patients with essential hypertension and coronary heart disease were enrolled in.The coronary heart disease was diagnosed by coronary angiography.Patients were divided into two groups.One group was poor-controlled blood pressure group,whose SBP≥140 mm Hg and/or DBP≥90 mm Hg.The partnership group (1∶1)was well-controlled blood pressure group,which was defined as SBP < 140 mm Hg and DBP < 90 mm Hg.Arterial elasticity including [SVC (systemic

  20. External iliac artery injury secondary to indirect pressure wave effect from gunshot wound

    OpenAIRE

    Ng, Eugene; Choong, Andrew MTL

    2016-01-01

    In patients presenting with gunshot wounds, a high clinical suspicion of injury to vasculature and viscera remote from the projectile track is paramount. We present a case of a 17 year old male who sustained a gunshot wound to his abdomen and subsequently developed a right external iliac artery contusion requiring surgery as an indirect effect of the pressure wave from the bullet.

  1. Proprioceptive Neuromuscular Facilitation Flexibility Techniques: Acute Effects on Arterial Blood Pressure.

    Science.gov (United States)

    Cornelius, William L.; Craft-Hamm, Kelley

    1988-01-01

    The effects of stretching techniques on arterial blood pressure (ABP) were studied in three groups of 20 men each. Each group performed one of three proprioceptive neuromuscular facilitation (PNF) techniques. Results are presented. The study indicates that the benefits of stretching may outweigh the risk of elevated ABP. (JL)

  2. Small artery structure adapts to vasodilatation rather than to blood pressure during antihypertensive treatment

    DEFF Research Database (Denmark)

    2007-01-01

    OBJECTIVE: Correction of the abnormal structure of resistance arteries in essential hypertension may be an important treatment goal in addition to blood pressure (BP) reduction. We investigated how this may be achieved in a prospective clinical study. METHODS: Plethysmography was used to measure ...

  3. Pressure profile and morphology of the arteries along the giraffe limb

    DEFF Research Database (Denmark)

    Østergaard, Kristine Hovkjær; Bertelsen, Mads F.; Brøndum, Emil;

    2011-01-01

    Giraffes are the tallest animals on earth and the effects of gravity on their cardiovascular system have puzzled physiologists for centuries. The authors measured arterial and venous pressure in the foreleg of anesthetized giraffes, suspended in upright standing position, and determined the ratio...

  4. Fast and Accurate Pressure-Drop Prediction in Straightened Atherosclerotic Coronary Arteries

    NARCIS (Netherlands)

    J.T.C. Schrauwen (Jelle); D. Koeze (Dion); J.J. Wentzel (Jolanda); F.N. van de Vosse (Frans); A.F.W. van der Steen (Ton); F.J.H. Gijsen (Frank)

    2014-01-01

    textabstractAtherosclerotic disease progression in coronary arteries is influenced by wall shear stress. To compute patient-specific wall shear stress, computational fluid dynamics (CFD) is required. In this study we propose a method for computing the pressure-drop in regions proximal and distal to

  5. Geometry-based pressure drop prediction in mildly diseased human coronary arteries

    NARCIS (Netherlands)

    J.T.C. Schrauwen (Jelle); J.J. Wentzel (Jolanda); A.F.W. van der Steen (Ton); F.J.H. Gijsen (Frank)

    2014-01-01

    textabstractPressure drop (△. p) estimations in human coronary arteries have several important applications, including determination of appropriate boundary conditions for CFD and estimation of fractional flow reserve (FFR). In this study a △. p prediction was made based on geometrical features deri

  6. Phylloquinone (vitamin K₁) intake and pulse pressure as a measure of arterial stiffness in older adults.

    Science.gov (United States)

    Vaccaro, Joan A; Huffman, Fatma G

    2013-01-01

    This study examined the relationships among ethnicity/race, lifestyle factors, phylloquinone (vitamin K₁) intake, and arterial pulse pressure in a nationally representative sample of older adults from four ethnic/racial groups: non-Hispanic Whites, non-Hispanic Blacks, Mexican Americans, and other Hispanics. This was a cross-sectional study of U.S. representative sample with data from the National Health and Nutrition Examination Surveys, 2007-2008 and 2009-2010 of adults aged 50 years and older (N = 5296). Vitamin K intake was determined by 24-hour recall. Pulse pressure was calculated as the difference between the averages of systolic blood pressure and diastolic blood pressure. Compared to White non-Hispanics, the other ethnic/racial groups were more likely to have inadequate vitamin K₁ intake. Inadequate vitamin K₁ intake was an independent predictor of high arterial pulse pressure. This was the first study that compared vitamin K₁ inadequacy with arterial pulse pressure across ethnicities/races in U.S. older adults. These findings suggest that vitamin K screening may be a beneficial marker for the health of older adults.

  7. A comparison of pulmonary arterial occlusion algorithms for estimation of pulmonary capillary pressure.

    Science.gov (United States)

    Pellett, A A; Johnson, R W; Morrison, G G; Champagne, M S; deBoisblanc, B P; Levitzky, M G

    1999-07-01

    Using the arterial occlusion method, we compared five literature-based estimates of pulmonary capillary pressure (Ppc) with the corresponding double occlusion pressures (Pdo) in anesthetized dogs whose chests had been closed after sternotomy for instrumentation. Arterial occlusions were performed with a balloon-tipped pulmonary artery catheter that housed pressure transducers immediately proximal and distal to the balloon. Separation of the proximal and distal pressure waveforms during balloon inflation allowed us to precisely define the moment of occlusion. We fit a monoexponential curve to pressure data beginning 200 ms after the onset of occlusion and a biexponential curve to data beginning at the instant of occlusion, with data obtained over a range of vascular states (control, serotonin infusion, histamine infusion). In addition, we investigated the use of sampling of the raw data to estimate capillary pressure. Three of the five literature-based estimates of Ppc yielded values similar to Pdo. The optimal (least average difference from Pdo) interpolation/extrapolation time points of the curve fits varied, depending on the type of curve fitting and the state of the pulmonary vasculature. We also determined that a close approximation of Pdo may be derived from the raw data, as an alternative to exponential curve fitting.

  8. Noninvasive arterial blood pressure waveform monitoring using two- element ultrasound system.

    Science.gov (United States)

    Seo, Joohyun; Pietrangelo, Sabino J; Lee, Hae-Seung; Sodini, Charles G

    2015-04-01

    This work details noninvasive arterial blood pressure (ABP) waveform estimation based on an arterial vessel cross-sectional area measurement combined with an elasticity measurement of the vessel, represented by pulse wave velocity (PWV), using a two-element ultrasound system. The overall ABP waveform estimation is validated in a custom-designed experimental setup mimicking the heart and an arterial vessel segment with two single element transducers, assuming a constant hemodynamic system. The estimation of local PWV using the flow-area method produces unbiased elasticity estimation of the tube in a pressure waveform comparison. The measured PWV using 16 cardiac cycles of data is 8.47 + 0.63 m/s with an associated scaling error of -1.56 + 14.0% in a direct pressure waveform comparison, showing negligible bias error on average. The distension waveform obtained from a complex cross-correlation model estimator (C3M) reliably traces small pressure changes reflected by the diameter change. The excellent agreement of an estimated pressure waveform to the reference pressure waveform suggests the promising potential of a readily available, inexpensive, and portable ABP waveform monitoring device.

  9. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  10. Valores de pressão arterial e suas associações com fatores de risco cardiovasculares em servidores da Universidade de Brasília Blood pressure levels and their association with cardiovascular risk factors among employees of the University of Brasília, a Brazilian public university

    Directory of Open Access Journals (Sweden)

    Tatiana Valverde da Conceição

    2006-01-01

    Full Text Available OBJETIVO: Verificar e classificar, de acordo com o JNC 7, os níveis de pressão arterial dos servidores acima de quarenta anos da Universidade de Brasília, e estimar a prevalência de fatores de risco cardiovasculares presentes em tal população. MÉTODOS: Foi realizado um estudo transversal na Universidade de Brasília, onde os servidores acima de quarenta anos responderam a um questionário e tiveram pressão arterial, peso e altura medidos. Os níveis de pressão arterial foram classificados de acordo com o JNC 7 e os dados demográficos dos indivíduos de cada categoria foram analisados. A porcentagem dos fatores de risco foi calculada. A análise estatística foi feita através do teste ANOVA e do teste qui-quadrado, quando aplicável. RESULTADOS: Setecentos e quatro servidores participaram do estudo, incluindo 438 homens e 266 mulheres. A mediana de idade foi 47 anos. Segundo o JNC 7, 139 (19,8% pessoas foram classificadas como normotensas; 298 (42,3% como pré-hipertensas e 267 (37,9% como hipertensas. Os fatores de risco avaliados foram sobrepeso/obesidade (56,8%, tabagismo (19,5%, consumo de bebidas alcoólicas (53,6%, sedentarismo (48,4% e hipertensão (37,9%. CONCLUSÃO: A alta freqüência de níveis pressóricos elevados e fatores de risco cardiovasculares apontam para a necessidade de medidas preventivas e terapêuticas de doenças cardiovasculares direcionadas aos servidores da universidade.OBJECTIVE: To verify and classify, according to the JNC 7, the blood pressure levels (BPL of the employees of University of Brasilia, a public university in Brazil, who are older than 40 years of age, and to estimate the prevalence of cardiovascular risk factors in this population. METHODS: A cross-sectional study was conducted at the University of Brasilia, with employees over 40 years of age. They answered a questionnaire and had their blood pressure, weight and height measured. The BPLs were classified according to the JNC 7

  11. Long-term pressure monitoring with arterial applanation tonometry : a non-invasive alternative during clinical intervention?

    NARCIS (Netherlands)

    Matthys, Koen S; Kalmar, Alain F; Struys, Michel M R F; Mortier, Eric P; Avolio, Alberto P; Segers, Patrick; Verdonck, Pascal R

    2008-01-01

    Arterial tonometry is a non-invasive technique for continuous registration of arterial pressure waveforms. This study aims to assess tonometric blood pressure recording (TBP) as an alternative for invasive long-term bedside monitoring. A prospective study was set up where patients undergoing neurosu

  12. Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress

    NARCIS (Netherlands)

    Harms, M.P.M.; Wesseling, K.H.; Pott, F.; Jenstrup, M.; Goudoever, J. van; Secher, N.H.; Lieshout, J.J. van

    1999-01-01

    The relationship between aortic flow and pressure is described by a three-element model of the arterial input impedance, including continuous correction for variations in the diameter and the compliance of the aorta (Modelflow). We computed the aortic flow from arterial pressure by this model, and

  13. Estudo comparativo da pressão arterial e da prevalência de hipertensão arterial em duas coortes sucessivas (1975-1976 de estudantes de 16 a 25 anos, Botucatu, SP, Brasil Blood pressure levels and hipertension prevalence in 16 to 25 year-old students in Botucatu, S. Paulo, Brazil. A comparative study of two successive cohorts, 1975-1976

    Directory of Open Access Journals (Sweden)

    Dináh Borges de Almeida

    1978-12-01

    Full Text Available Com o objetivo de determinar os níveis de pressão arterial e a prevalência de hipertensão arterial em uma população jovem, foram realizados pesquisas em dois anos sucessivos em 1.288 e 736 estudantes de Botucatu, SP (Brasil tendo sido comparados os resultados obtidos. As médias das pressões sistólicas da população estudada e dos dois grupos etários desta população (16 a 20 anos e 21 a 25 anos foram idênticas em ambos os anos, tendo as médias das pressões diastólicas diferido de no máximo 2 mmHg; as médias, tanto sistólicas quanto diastólicas, dos dois sexos e da parcela branca da população estudada quanto à idade e sexo também diferiram de no máximo 2 mmHg. As médias da população estudada e sua parcela branca, em ambos os anos, foram superiores no sexo masculino e no grupo etário de 21 a 25 anos. Na população negra e amarela houve disparidade de resultados entre 1975 e 1976, indicando influência da exiguidade do tamanho dos contigentes negro e amarelo desta população. A prevalência de hipertensão arterial (pressão sistólica igual ou maior que 140 mmHg e diastólica igual ou maior que 90 mmHg foi de 5,04% em 1975 e 6,22% em 1976, tendo sido em ambos os anos maior no sexo masculino do que no feminino e no grupo de 21 a 25 do que no de 16 a 20 anos.To determine the prevalence of hypertension and blood pressure levels in a young population group, two groups, one of 1288 students and another of 736, all from Botucatu, were investigated during two consecutive years, and the results were then compared. The mean values for systolic readings of the whole population, as for the two age groups (16 to 20 and 21 to 25 years old, were identical for both years studied; the diastolic mean values differed by 2 mmHg at most. The mean systolic and diastolic reading for both sexes and among the whites also differed by 2 mmHg at most. The mean values for the whole population and among the white population were higher for males

  14. Measurement of pleural pressure swings with a fluid-filled esophageal catheter vs pulmonary artery occlusion pressure.

    Science.gov (United States)

    Verscheure, S; Massion, P B; Gottfried, S; Goldberg, P; Samy, L; Damas, P; Magder, S

    2017-02-01

    Pleural pressure measured with esophageal balloon catheters (Peso) can guide ventilator management and help with the interpretation of hemodynamic measurements, but these catheters are not readily available or easy to use. We tested the utility of an inexpensive, fluid-filled esophageal catheter (Peso) by comparing respiratory-induced changes in pulmonary artery occlusion (Ppao), central venous (CVP), and Peso pressures. We studied 30 patients undergoing elective cardiac surgery who had pulmonary artery and esophageal catheters in place. Proper placement was confirmed by chest compression with airway occlusion. Measurements were made during pressure-regulated volume control (VC) and pressure support (PS) ventilation. The fluid-filled esophageal catheter provided a high-quality signal. During VC and PS, change in Ppao (∆Ppao) was greater than ∆Peso (bias = -2 mm Hg) indicating an inspiratory increase in cardiac filling. During VC, ∆CVP bias was 0 indicating no change in right heart filling, but during PS, CVP fell less than Peso indicating an inspiratory increase in filling. Peso measurements detected activation of expiratory muscles, development of non-west zone 3 lung conditions during inspiration, and ventilator-triggered inspiratory efforts. A fluid-filled esophageal catheter provides a high-quality, easily accessible, and inexpensive measure of change in pleural pressure and provided insights into patient-ventilator interactions. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Cardiac output in idiopathic normal pressure hydrocephalus: association with arterial blood pressure and intracranial pressure wave amplitudes and outcome of shunt surgery

    Directory of Open Access Journals (Sweden)

    Eide Per K

    2011-02-01

    Full Text Available Abstract Background In patients with idiopathic normal pressure hydrocephalus (iNPH responding to shunt surgery, we have consistently found elevated intracranial pressure (ICP wave amplitudes during diagnostic ICP monitoring prior to surgery. It remains unknown why ICP wave amplitudes are increased in these patients. Since iNPH is accompanied by a high incidence of vascular co-morbidity, a possible explanation is that there is reduced vascular compliance accompanied by elevated arterial blood pressure (ABP wave amplitudes and even altered cardiac output (CO. To investigate this possibility, the present study was undertaken to continuously monitor CO to determine if it is correlated to ABP and ICP wave amplitudes and the outcome of shunting in iNPH patients. It was specifically addressed whether the increased ICP wave amplitudes seen in iNPH shunt responders were accompanied by elevated CO and/or ABP wave amplitude levels. Methods Prospective iNPH patients (29 were clinically graded using an NPH grading scale. Continuous overnight minimally-invasive monitoring of CO and ABP was done simultaneously with ICP monitoring; the CO, ABP, and ICP parameters were parsed into 6-second time windows. Patients were assessed for shunt surgery on clinical grade, Evan's index, and ICP wave amplitude. Follow-up clinical grading was performed 12 months after surgery. Results ICP wave amplitudes but not CO or ABP wave amplitude, showed good correlation with the response to shunt treatment. The patients with high ICP wave amplitude did not have accompanying high levels of CO or ABP wave amplitude. Correlation analysis between CO and ICP wave amplitudes in individual patients showed different profiles [significantly positive in 10 (35% and significantly negative in 16 (55% of 29 recordings]. This depended on whether there was also a correlation between ABP and ICP wave amplitudes and on the average level of ICP wave amplitude. Conclusions These results gave no

  16. Roles of Arterial Stiffness and Blood Pressure in Hypertension-Associated Cognitive Decline in Healthy Adults.

    Science.gov (United States)

    Hajjar, Ihab; Goldstein, Felicia C; Martin, Greg S; Quyyumi, Arshed A

    2016-01-01

    Although there is strong evidence that hypertension leads to cognitive decline, especially in the executive domain, the relationship between blood pressure and cognition has been conflicted. Hypertension is characterized by blood pressure elevation and increased arterial stiffness. We aimed at investigating whether arterial stiffness would be superior to blood pressure in predicting cognitive decline and explaining the hypertension-executive decline association. A randomly selected asymptomatic population (n=591, age=49.2 years, 70% women, 27% black, and education=18 years) underwent annual vascular and cognitive assessments. Cognition was assessed using computerized versions commonly used cognitive tests, and principal component analysis was used for deriving cognitive scores for executive function, memory, and working memory. Arterial stiffness was measured by carotid-femoral pulse wave velocity (PWV). Higher PWV, but not blood pressure, was associated with a steeper decline in executive (P=0.0002), memory (P=0.05), and working memory (P=0.02) scores after adjusting for demographics, education, and baseline cognitive performance. This remained true after adjusting for hypertension. Hypertension was associated with greater decline in executive score (P=0.0029) and those with combined hypertension and elevated PWV (>7 m/s) had the greatest decline in executive score (P value hypertension×PWV=0.02). PWV explained the association between hypertension and executive function (P value for hypertension=0.0029 versus 0.24 when adjusting for PWV). In healthy adults, increased arterial stiffness is superior to blood pressure in predicting cognitive decline in all domains and in explaining the hypertension-executive function association. Arterial stiffness, especially in hypertension, may be a target in the prevention of cognitive decline.

  17. Real-time Doppler-based arterial vascular impedance and peripheral pressure-flow loops: a pilot study.

    Science.gov (United States)

    Thiele, Robert H; Bartels, Karsten; Esper, Stephen; Ikeda, Keita; Gan, Tong-Joo

    2014-02-01

    Arterial pressure-flow loops and vascular impedance provide additional data that could be used to assess the hemodynamic effects of therapeutic interventions in anesthetized patients. To evaluate the utility of such an approach, the authors sought to design a device that combines flow waveforms from an esophageal Doppler probe and pressure waveforms from a peripheral artery to produce real-time pressure-flow loops and estimates of arterial vascular impedance. Prospective, cohort study. Single center, university-based teaching hospital. Patients undergoing surgery in whom the attending anesthesiologist had opted to place an esophageal Doppler probe and a peripheral arterial catheter for hemodynamic monitoring. This was a non-interventional study designed to record pressure-flow loops and arterial vascular impedance intraoperatively using a novel, noninvasive device. Pressure-flow loops and arterial vascular impedance were measured noninvasively using radial artery pressure and descending thoracic aorta flow waveforms in real time. Real-time arterial vascular impedance and peripheral pressure-volume loops can be determined using available monitoring devices. Technical feasibility of this technology in patients is a crucial first step to permit meaningful evaluation of the clinical value of this approach for accurate determination of complex hemodynamic indices and, eventually, improvement of outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. New Cardiovascular Indices Based on a Nonlinear Spectral Analysis of Arterial Blood Pressure Waveforms

    CERN Document Server

    Laleg, Taous-Meriem; Papelier, Yves; Crépeau, Emmanuelle; Sorine, Michel

    2007-01-01

    A new method for analyzing arterial blood pressure is presented in this report. The technique is based on the scattering transform and consists in solving the spectral problem associated to a one-dimensional Schr\\"odinger operator with a potential depending linearly upon the pressure. This potential is then expressed with the discrete spectrum which includes negative eigenvalues and corresponds to the interacting components of an N-soliton. The approach is similar to a nonlinear Fourier transform where the solitons play the role of sine and cosine components. The method provides new cardiovascular indices that seem to contain relevant physiological information. We first show how to use this approach to decompose the arterial blood pressure pulse into elementary waves and to reconstruct it or to separate its systolic and diastolic phases. Then we analyse the parameters computed from this technique in two physiological conditions, the head-up 60 degrees tilt test and the isometric handgrip test, widely used for...

  19. Arterial blood-pressure change and endogenous circulating substance P in man

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Kastrup, J; Schaffalitzky De Muckadell, O B

    1985-01-01

    Substance P (SP) is a powerful vasodilator and this peptide is today considered to be a chemical messenger. The potential effects on circulating SP of acute changes in arterial blood-pressure was investigated in nine subjects. An increase in arterial mean blood-pressure (+33%, P less than 0.001, n...... = 9) was obtained by infusion of angiotensin II and a decrease in pressure (-10%, P less than 0.005, n = 6) was obtained by ganglionic blockade. The concentration of SP in plasma, from supine subjects in the normotensive condition, ranged from 3 to 13 pmol/l (with a mean of 5.6 pmol/l). SP was thus...

  20. Energy harvesting from arterial blood pressure for powering embedded micro sensors in human brain

    Science.gov (United States)

    Nanda, Aditya; Karami, M. Amin

    2017-03-01

    This manuscript investigates energy harvesting from arterial blood pressure via the piezoelectric effect for the purpose of powering embedded micro-sensors in the human brain. One of the major hurdles in recording and measuring electrical data in the human nervous system is the lack of implantable and long term interfaces that record neural activity for extended periods of time. Recently, some authors have proposed micro sensors implanted deep in the brain that measure local electrical and physiological data which are then communicated to an external interrogator. This paper proposes a way of powering such interfaces. The geometry of the proposed harvester consists of a piezoelectric, circular, curved bimorph that fits into the blood vessel (specifically, the Carotid artery) and undergoes bending motion because of blood pressure variation. In addition, the harvester thickness is constrained such that it does not modify arterial wall dynamics. This transforms the problem into a known strain problem and the integral form of Gauss's law is used to obtain an equation relating arterial wall motion to the induced voltage. The theoretical model is validated by means of a Multiphysics 3D-FEA simulation comparing the harvested power at different load resistances. The peak harvested power achieved for the Carotid artery (proximal to Brain), with PZT-5H, was 11.7 μW. The peak power for the Aorta was 203.4 μW. Further, the variation of harvested power with variation in the harvester width and thickness, arterial contractility, and pulse rate is investigated. Moreover, potential application of the harvester as a chronic, implantable and real-time Blood pressure sensor is considered. Energy harvested via this mechanism will also have applications in long-term, implantable Brain Micro-stimulation.

  1. Systolic blood pressure, arterial rigidity, and risk of stroke. The Framingham study.

    Science.gov (United States)

    Kannel, W B; Wolf, P A; McGee, D L; Dawber, T R; McNamara, P; Castelli, W P

    1981-03-27

    Based on prospective data from the Framingham study relating systolic pressure, diastolic pressure, age, and pulse-wave configuration to future stroke incidence, it would appear that isolated systolic hypertension predisposes to stroke independent of arterial rigidity. The prevalence of isolated systolic hypertension increased with age and with the degree of blunting of the dicrotic notch in the pulse wave. Subjects with isolated systolic hypertension experienced two to four times as many strokes as did normotensive persons. While diastolic pressure is related to stroke incidence, in the subject with systolic hypertension, the diastolic component adds little to risk assessment and in men, in this subgroup, appears unrelated to stroke incidence.

  2. Atrial distension, arterial pulsation, and vasopressin release during negative pressure breathing in humans

    DEFF Research Database (Denmark)

    Pump, B; Damgaard, M; Gabrielsen, A

    2001-01-01

    in eight healthy males, we tested the hypothesis that with similar increases in LA diameter, suppression of AVP release is dependent on the degree of increase in PP. LA diameter increased similarly during the posture change and negative pressure breathing (-9 to -24 mmHg) from between 30 and 31 +/- 1 to 34......During an antiorthostatic posture change, left atrial (LA) diameter and arterial pulse pressure (PP) increase, and plasma arginine vasopressin (AVP) is suppressed. By comparing the effects of a 15-min posture change from seated to supine with those of 15-min seated negative pressure breathing...... +/- 1 mm (P breathing from 36 +/- 3 to 42 +/- 3 mmHg (P

  3. Sacral pressure sore reconstruction -- the pedicled superior gluteal artery perforator flap.

    Science.gov (United States)

    Hurbungs, A; Ramkalawan, H

    2012-02-14

    To report the use of the pedicled superior gluteal artery perforator (SGAP) fasciocutaneous flap as a reliable surgical option for sacral pressure sore reconstruction. A prospective study was conducted between September 2008 and September 2010 of 10 patients with stage 3 or 4 sacral pressure sores treated with a unilateral pedicled SGAP flap. All flaps survived completely with no complications in 9 patients. One patient had a haematoma below the flap that was easily drained. No recurrence of the bedsore occurred during follow-up. We suggest that the pedicled SGAP fasciocutaneous flap is a reliable surgical option for sacral pressure sore reconstruction.

  4. Atrial distension, arterial pulsation, and vasopressin release during negative pressure breathing in humans

    DEFF Research Database (Denmark)

    Pump, B; Damgaard, M; Gabrielsen, A;

    2001-01-01

    During an antiorthostatic posture change, left atrial (LA) diameter and arterial pulse pressure (PP) increase, and plasma arginine vasopressin (AVP) is suppressed. By comparing the effects of a 15-min posture change from seated to supine with those of 15-min seated negative pressure breathing...... in eight healthy males, we tested the hypothesis that with similar increases in LA diameter, suppression of AVP release is dependent on the degree of increase in PP. LA diameter increased similarly during the posture change and negative pressure breathing (-9 to -24 mmHg) from between 30 and 31 +/- 1 to 34...... +/- 1 mm (P breathing from 36 +/- 3 to 42 +/- 3 mmHg (P

  5. Skin perfusion pressure measured by isotope washout in legs with arterial occlusive disease. Evaluation of different tracers, comparison to segmental systolic pressure, angiography and transcutaneous oxygen tension and variations during changes in systemic blood pressure

    DEFF Research Database (Denmark)

    Holstein, P; Trap-Jensen, J; Bagger, H;

    1983-01-01

    digit (strain gauge technique). The two different methods correlated statistically significant at all four levels, but the systolic blood pressures were higher than the SPP in particular in diabetic legs; (3) Angiograms in 35 legs with AOD showed that the SPP on the ankle was only consistently decreased......The skin perfusion pressure (SPP) measured as the isotope washout cessation external pressure is valuable in selection of major amputation level. Five methodological investigations important to clinical use were carried out: (1) In five normal legs and 10 legs with arterial occlusive disease (AOD......Hg (range 18-98) (P less than 0.02). The average washout constant for the three different tracers were approximately equal and correlated statistically significant with the SPP; (2) In 59 legs with AOD, segmental SPP was compared to segmental systolic blood pressures on the thigh, calf, ankle and first...

  6. Impacto do tratamento de sobrepeso/obesidade sobre os níveis de pressão arterial na Atenção Primária à Saúde The impact of weight reduction therapy on blood pressure levels in Primary Care

    Directory of Open Access Journals (Sweden)

    Daniel Victor Arantes

    2010-11-01

    ção de 0,88 e 0,72 mmHg nas PAS e PAD, respectivamente. O tratamento da obesidade engloba mudanças de hábitos de vida que em conjunto com a redução ponderal promovem benefícios clínicos significativos já observáveis em reduções inferiores a 10% do peso inicial, em especial naqueles que apresentam comorbidades. O diagnóstico é simples e o acompanhamento de baixo custo, principalmente se for estruturado com atividades educativas em grupo e motivação para mudanças de hábitos de vida. A farmacoterapia pode ser útil e segura, desde que figure como coadjuvante no tratamento. Este estudo mostra como pode ser simples executar um programa estruturado, de baixo custo e efetivo, com replicabilidade dos benefícios descritos na literatura científica.In the last decades the incidence and prevalence of overweight and obesity are increasing drastically over the world. It is estimated that in Brazil 32% of adults are overweight and 8% obese, totalizing 40% of adults over the weight levels recommended for a healthy life. The situation is even more critical in the low-income population with poor educational level, where the problem is advancing even faster. Obesity figures among the most important risk factors for cardio-vascular diseases and there is strong scientific evidence that even modest weight reduction leads to significant clinical benefits. Thus, offering treatment for overweight and obesity in primary care can evidently improve the health and quality of life of the population and reduce the final public health expenditures. The purpose of this study is to evaluate the applicability and impact of a weight reduction program on the blood pressure levels of a group of patients assisted in a public primary care program called ‘Estratégia de Saúde da Família’ (Family Health Strategy and to propose ways for standardizing this program. A retrospective analytic study was conducted for comparing the clinical data of patients submitted to weight reduction therapy

  7. Blood Pressure Control in Smokers with Arterial Hypertension Who Switched to Electronic Cigarettes

    Directory of Open Access Journals (Sweden)

    Riccardo Polosa

    2016-11-01

    Full Text Available Electronic cigarettes (ECs are battery-operated devices designed to vaporise nicotine, which may help smokers with quitting or reducing their tobacco consumption. No data is available regarding the health effects of ECs use among smokers with arterial hypertension and whether regular use results in blood pressure (BP changes. We investigated long-term changes in resting BP and level of BP control in hypertensive smokers who quit or reduced substantially their tobacco consumption by switching to ECs. A medical records review of patients with hypertension was conducted to identify patients reporting regular daily use of ECs on at least two consecutive follow-up visits. Regularly smoking hypertensive patients were included as a reference group. A marked reduction in cigarette consumption was observed in ECs users (n = 43 though consumption remained unchanged in the control group (n = 46. Compared to baseline, at 12 months (follow-up visit 2 decline in cigarette consumption was associated with significant reductions in median (25th-, 75th-centile systolic BP (140 (134.5, 144 to 130 (123.5, 138.5 mmHg; p < 0.001 and diastolic BP (86 (78, 90 to 80 (74.5, 90 mmHg; p = 0.006. No significant changes were observed in the control group. As expected, decline in cigarette consumption in the ECs users was also associated with improved BP control. The study concludes that regular ECs use may aid smokers with arterial hypertension reduce or abstain from cigarette smoking, with only trivial post-cessation weight gain. This resulted in improvements in systolic and diastolic BP as well as better BP control.

  8. Blood Pressure Control in Smokers with Arterial Hypertension Who Switched to Electronic Cigarettes

    Science.gov (United States)

    Polosa, Riccardo; Morjaria, Jaymin B.; Caponnetto, Pasquale; Battaglia, Eliana; Russo, Cristina; Ciampi, Claudio; Adams, George; Bruno, Cosimo M.

    2016-01-01

    Electronic cigarettes (ECs) are battery-operated devices designed to vaporise nicotine, which may help smokers with quitting or reducing their tobacco consumption. No data is available regarding the health effects of ECs use among smokers with arterial hypertension and whether regular use results in blood pressure (BP) changes. We investigated long-term changes in resting BP and level of BP control in hypertensive smokers who quit or reduced substantially their tobacco consumption by switching to ECs. A medical records review of patients with hypertension was conducted to identify patients reporting regular daily use of ECs on at least two consecutive follow-up visits. Regularly smoking hypertensive patients were included as a reference group. A marked reduction in cigarette consumption was observed in ECs users (n = 43) though consumption remained unchanged in the control group (n = 46). Compared to baseline, at 12 months (follow-up visit 2) decline in cigarette consumption was associated with significant reductions in median (25th-, 75th-centile) systolic BP (140 (134.5, 144) to 130 (123.5, 138.5) mmHg; p < 0.001) and diastolic BP (86 (78, 90) to 80 (74.5, 90) mmHg; p = 0.006). No significant changes were observed in the control group. As expected, decline in cigarette consumption in the ECs users was also associated with improved BP control. The study concludes that regular ECs use may aid smokers with arterial hypertension reduce or abstain from cigarette smoking, with only trivial post-cessation weight gain. This resulted in improvements in systolic and diastolic BP as well as better BP control. PMID:27845734

  9. [Assessment of arterial wall stiffness by 24-hour blood pressure monitoring].

    Science.gov (United States)

    Korneva, V A; Kuznetsova, T Yu

    2016-01-01

    Arterial wall stiffness is an early marker of cardiovascular diseases. The gold standard for assessment of the stiffness of large vessels is presently pulse wave velocity (PWV). Work is in progress on the study of the reference values of PWV in people of different genders and ages. 24-hour blood pressure (BP) monitoring is not only a procedure that can estimate diurnal BP variability, but also monitor the indicators of vascular wall stiffness in a number of cases over a 24-hour period. The given review highlights the pathophysiology of arterial stiffness, methods for its assessment, and the aspects of use in therapeutic practice.

  10. Perfil dos níveis pressóricos e glicêmicos de funcionários de instituições públicas hospitalares de Fortaleza-Ceará: profile of the public hospitals' staff in the city of Fortaleza-CE Perfil de los niveles de glucosa e de tensión arterial de trabajadores de hospitales públicos de Fortaleza-CE Glucose and blood pressure level

    Directory of Open Access Journals (Sweden)

    Marta Maria Coelho Damasceno

    2006-08-01

    Full Text Available Objetivou-se identificar o perfil dos níveis pressóricos e glicêmicos de funcionários de dois hospitais públicos de Fortaleza-CE. Aferiram-se os valores em 506 sujeitos utilizando glicosímetro e esfigmomanômetro aneróide, de setembro de 2003 a abril de 2004. As idades variaram entre 18 e 71 anos; 79,6% eram mulheres; 49,3% pré-hipertensos; 19,5% hipertensos; 7,9% com glicemia > 140 mg/dl; 38,5% com alto risco para DM2. A PA foi mais elevada nos homens (pEl objetivo fué identificar el perfil de los niveles de glucosa y de tensión arterial de trabajadores de dos hospitales públicos de Fortaleza-CE. Se tomarón los valores en 506 personas con el Sistema de Medición de Glucosa en sangre y esfigmomanómetro aneroide, de septiembre de 2003 a abril de 2004. Las edades cambiaron entre 18 a 71 años; 79,6% mujeres; 49,3% tenian prehipertensión arterial; 19,5% hipertensión arterial; 7,9% con glucosa mas de 140 mg/dl; 38,5% con alto riesgo para DM2. La tensión arterial fue más elevada en hombres (pIt was objectified to identify the profile of the glucose and blood pressure in two public hospitals' staff in Fortaleza - CE . From September 2003 to April 2004, were checked 506 individuals with Blood Glucose Monitoring System and aneroid sphygmomanometer. The results showed that the individuals were between 18 and 71 years old; 79,6% were women; 49,3 were classified as prehypertensive; 19.5% as hypertensive; 7.9% had glucose level above 140mg/dl and 38.5% had high chances of developing DM2. High blood pressure was higher in men (p<0.001; the illiterates/literates ( p=0.031 and the married and widowed (p=0.029. This high blood pressure was associated with age (p<0.001; As to the glucose levels, a statistically meaningful association with age and high glucose (p=0.006 was verified. It follows that the studied population, especially the elderly and low educated, need educational actions which help to change their life habits and prevent illnesses

  11. Arterial pressure changes monitoring with a new precordial noninvasive sensor

    Directory of Open Access Journals (Sweden)

    Faita Francesco

    2008-08-01

    Full Text Available Abstract Background Recently, a cutaneous force-frequency relation recording system based on first heart sound amplitude vibrations has been validated. A further application is the assessment of Second Heart Sound (S2 amplitude variations at increasing heart rates. The aim of this study was to assess the relationship between second heart sound amplitude variations at increasing heart rates and hemodynamic changes. Methods The transcutaneous force sensor was positioned in the precordial region in 146 consecutive patients referred for exercise (n = 99, dipyridamole (n = 41, or pacing stress (n = 6. The curve of S2 peak amplitude variation as a function of heart rate was computed as the increment with respect to the resting value. Results A consistent S2 signal was obtained in all patients. Baseline S2 was 7.2 ± 3.3 mg, increasing to 12.7 ± 7.7 mg at peak stress. S2 percentage increase was + 133 ± 104% in the 99 exercise, + 2 ± 22% in the 41 dipyridamole, and + 31 ± 27% in the 6 pacing patients (p Conclusion S2 recording quantitatively documents systemic pressure changes.

  12. Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine.

    Science.gov (United States)

    Monnet, Xavier; Letierce, Alexia; Hamzaoui, Olfa; Chemla, Denis; Anguel, Nadia; Osman, David; Richard, Christian; Teboul, Jean-Louis

    2011-06-01

    To evaluate to which extent the systemic arterial pulse pressure could be used as a surrogate of cardiac output for assessing the effects of a fluid challenge and of norepinephrine. Observational study. Medical intensive care unit. Patients with an acute circulatory failure who received a fluid challenge (228 patients, group 1) or in whom norepinephrine was introduced or increased (145 patients, group 2). We measured the systolic, diastolic, and mean arterial pressure, pulse pressure, and the transpulmonary thermodilution cardiac output before and after the therapeutic interventions. In group 1, the fluid challenge significantly increased cardiac output by 24% ± 25%. It significantly increased cardiac output by ≥15% (+35% ± 27%) in 142 patients ("responders"). The fluid-induced changes in cardiac output were correlated with the changes in pulse pressure (r = .56, p arterial pressure (r = .55, p arterial pressure (r = .37, p arterial pressure (r = .52, p pressure were significantly related to changes in stroke volume (multiple r = .52) and to age (r = .12). A fluid-induced increase in pulse pressure of ≥17% allowed detecting a fluid-induced increase in cardiac output of ≥15% with a sensitivity of 65[56-72]% and a specificity of 85[76-92]%. The area under the receiver operating characteristic curves for the fluid-induced changes in mean arterial pressure and in diastolic arterial pressure was significantly lower than for pulse pressure. In group 2, the introduction/increase of norepinephrine significantly increased cardiac output by 14% ± 18%. The changes in cardiac output induced by the introduction/increase in the dose of norepinephrine were correlated with the changes in pulse pressure and systolic arterial pressure (r = .21 and .29, respectively, p = .001) but to a significantly lesser extent than in group 1. Pulse pressure and systolic arterial pressure could be used for detecting the fluid-induced changes in cardiac output, in spite of a significant

  13. Adiponectin Genotype, Blood Pressures, and Arterial Stiffness: The Cardiometabolic Risk in Chinese (CRC) Study.

    Science.gov (United States)

    Liang, Jun; Qiu, Qinqin; Gong, Ying; Liu, Xuekui; Dou, Lianjun; Zou, Caiyan; Wang, Yu; Qi, Lu

    2015-05-01

    The authors examined whether the adiponectin gene (ADIPOQ) variant was associated with blood pressure and arterial stiffness in Chinese adults. A genome-wide association study of the adiponectin variant rs864265 in the ADIPOQ gene was genotyped in a total of 2364 participants. After adjustment for sex, age, body mass index (BMI), fasting glucose, and lipids, participants carrying the T allele of rs864265 showed a greater increase in carotid-femoral pulse wave velocity (cfPWV) and systolic blood pressure (SBP). Further adjustment for blood pressure did not appreciably change the association with cfPWV. The authors found significant interactions between rs864265 and BMI, waist circumference, body fat percentage, and SBP in relation to cfPWV (P for interaction = .035, .001, .003, .013, respectively). The T allele of rs864265 was associated with high blood pressure and arterial stiffness. BMI, body fat percentage, waist circumference, and SBP might modify the effects of genetic polymorphism on arterial stiffness.

  14. [Left ventricular relaxation and ambulatory blood pressure in mild, untreated arterial hypertension].

    Science.gov (United States)

    Herpin, D; Raynier, P; Ciber, M; Amiel, A; Boutaud, P; Demange, J

    1989-03-01

    Twenty patients with mild, untreated arterial hypertension had ambulatory blood pressure recordings and a digitized echocardiographic study of the left ventricle with measurement of its mass (LVM) and of relaxation parameters. A significant correlation was found between LVM and ambulatory systolic pressure during daytime (r = 0.64; p less than 0.01; n = 20) and during 24 hours (r = 0.79; p less than 0.001; n = 16). One of the relaxation parameters studied, the time taken to reach maximal speed of left ventricular enlargement, was closely related to the diurnal diastolic blood pressure (r = 0.58; p less than 0.01; n = 20), whereas in this population with mild arterial blood pressure none of the parameters was related to the amount of increase of LVM. One may therefore consider the abnormalities of left ventricular relaxation as likely to appear at an early stage of arterial hypertension; their discovery may antedate that of LVM and confirm that the hypertensive disease is real. However, the methodological problems encountered with type of exploration ought to be stressed: left ventricular relaxation is a multifactorial phenomenon, and its echocardiographic approach is subject to many hazards.

  15. Healing of ulcers on the feet correlated with distal blood pressure measurements in occlusive arterial disease

    DEFF Research Database (Denmark)

    Holstein, P; Lassen, N A

    1980-01-01

    The frequency of healing in subchronic ulcers in 66 feet in 62 patients with arterial occlusive disease was correlated with the systolic digital blood pressure (SDBP) and the systolic ankle blood pressure (SABP), both measured with a strain gauge, and with the skin perfusion pressure on the heel...... of healing correlated significantly with the three distal blood pressure parameters investigated, the closest correlation being with the SDBP measured at the final examination, i.e. just after healing of the ulcer or just before an inevitable major amputation. Of the 22 cases with SDBP below 20 mmHg only two...... and peripheral neuropathy were frequent in the diabetic group. The data show that the systolic digital blood pressure is a particularly valuable prognostic parameter....

  16. Morning blood pressure surge and arterial stiffness in newly diagnosed hypertensive patients.

    Science.gov (United States)

    Kıvrak, Ali; Özbiçer, Süleyman; Kalkan, Gülhan Yüksel; Gür, Mustafa

    2017-06-01

    We aimed to investigate the relationship between the morning blood pressure (BP) surge and arterial stiffness in patients with newly diagnosed hypertension. Three hundred and twenty four (mean age 51.7 ± 11.4 years) patients who had newly diagnosed hypertension with 24 h ambulatory BP monitoring were enrolled. Parameters of arterial stiffness, pulse wave velocity and augmentation index (Aix) were measured by applanation tonometry and aortic distensibility was calculated by echocardiography. Compared with the other groups, pulse wave velocity, day-night systolic BP (SBP) difference (p arterial stiffness which is a surrogate endpoint for cardiovascular diseases. The inverse relationship between morning BP surge and aortic distensibility and direct relation found in our study is new to the literature.

  17. Theoretical study of dynamics of arterial wall remodeling in response to changes in blood pressure.

    Science.gov (United States)

    Rachev, A; Stergiopulos, N; Meister, J J

    1996-05-01

    The dynamics of arterial wall remodeling was studied on the basis of a phenomenological mathematical model. Sustained hypertension was simulated by a step increase in blood pressure. Remodeling rate equations were postulated for the evolution of the geometrical dimensions that characterize the zero stress state of the artery. The driving stimuli are the deviations of the extreme values of the circumferential stretch ratios and the average stress from their values at the normotensive state. Arterial wall was considered to be a thick-walled tube made of nonlinear elastic incompressible material. Results showed that thickness increases montonically with time whereas the opening angle exhibits a biphasic pattern. Geometric characteristics reach asymptotically a new homeostatic steady state, in which the stress and strain distribution is practically identical with the distribution under normotensive conditions. The model predictions are in good agreement with published experimental findings.

  18. Correlation between systemic blood pressure measured by oscillometry and age and serum sodium level in healthy dogsCorrelação entre a pressão arterial sistêmica aferida por método oscilométrico com a idade e o nível sérico de sódio em cães hígidos

    Directory of Open Access Journals (Sweden)

    Eduardo Garcia Fontoura

    2013-06-01

    Full Text Available Blood pressure has received attention in current veterinary clinic and can be measured in a non-invasive way by the oscillometric method, among others. Factors such as age have already been related to disorders on blood pressure. Sodium, vital element in cell physiology of animals, has been reported to increase blood pressure. Thus, this work correlates age, the values of blood pressure, both systolic and diastolic, with the serum levels of sodium in healthy adult dogs. We studied 23 adult healthy dogs of both sexes and varying age fed with commercial feed (standard. The arterial pressure, systolic (SBP and diastolic (DBP, and pulse were measured by digital human sphygmomanometer. The level of serum sodium was obtained by the method of enzyme reagent in kinetic mode, using a commercial kit. We performed Pearson correlation between variables. The values of SBP, DBP, pulse and serum sodium varied respectively from 96 – 184mmHg, 53 – 137mmHg, 64 – 135bpm and 120-157mEq/L. We observed a positive correlation between the variables age and SBP, age and DBP, SBP and sodium, and sodium and DBP, while the values of serum sodium and age showed a negative correlation. Regarding this study conditions, we conclude that there is little interference in the values of blood pressure, both systolic and diastolic, regarding age and serum sodium in healthy adult dogs. A pressão arterial vem recebendo destaque na clínica veterinária atual, podendo ser mensurada de forma não-invasiva, pelo método oscilométrico, entre outros. Fatores como a idade já foram relacionados com distúrbios na pressão arterial. O sódio, elemento vital na fisiologia celular de animais, já foi relacionado com o aumento da pressão arterial. Desta forma, este trabalho correlaciona a idade, os valores da pressão arterial sistêmica, sistólica e diastólica, com os níveis séricos de sódio em cães adultos hígidos. Foram estudados 23 cães adultos, hígidos, de ambos os sexos

  19. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Science.gov (United States)

    Kyriacou, P. A.; Shafqat, K.; Pal, S. K.

    2007-10-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  20. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Shafqat, K [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Pal, S K [St Andrew' s Centre for Plastic Surgery and Burns, Broomfield Hospital, Chelmsford, CM1 7ET (United Kingdom)

    2007-10-15

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO{sub 2}) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO{sub 2}) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO{sub 2} sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures

  1. Effects of pressure-dependent segmental arterial compliance and postural changes on pulse wave transmission in an arterial model of the human upper limb.

    Science.gov (United States)

    Xu, Ke; Butlin, Mark; Avolio, Alberto P

    2011-01-01

    With increasing interest in the effect of postural changes on arterial blood pressure and vascular properties, it is important to understand effects of pressure-dependent arterial compliance. This study investigates effects of pressure-dependent compliance on pulse wave velocity (PWVar), pressure wave shape, and transmission characteristics in an arterial model of the human arm from heart to radial artery from supine to standing. Estimated central pressure waveform was used as the input for the model, calculated using a validated transfer function (SphygmoCor, AtCor Medical) from recorded radial pulses in 10 healthy male subjects (53.8 ± 7.9 years) during 0, 30, 60 and 90 degree head-up tilt. A 5-segment linear model was optimized using estimated central and recorded radial arterial pulse; each segment represented by an equivalent inductance, resistance and capacitance (compliance (C)) Pressure-dependent compliance (C(P)=a · e(b · P) was added to develop a nonlinear model, and the radial pulse calculated. Comparison of the radial pulse calculated by the linear and nonlinear models showed no statistical difference in systolic, diastolic, mean, and pulse pressure in any position of tilt. However, waveform shape was increasingly divergent at higher angles of tilt (RMS error 2.3 ± 1.2 mmHg supine, 6.5 ± 3.0 mmHg standing) as was PWVar (0% increase from supine to standing in the linear model, 16.7% increase in nonlinear model). Fourier analysis demonstrated peak amplitude of transmission being at higher frequencies and phase delay being lower in the nonlinear model relative to the linear model. Pressure-dependent arterial compliance, whilst having no effect on peak values of pressure, has significant effects on waveform shape and transmission speed, especially with a more upright position.

  2. Effects of simulated microgravity on circadian rhythm of caudal arterial pressure and heart rate in rats and their underlying mechanism

    Directory of Open Access Journals (Sweden)

    Li CHEN

    2016-04-01

    Full Text Available Objective  To explore the effects of simulated microgravity on the circadian rhythm of rats' caudal arterial pressure and heart rate, and their underlying mechanism. Methods  Eighteen male SD rats (aged 8 weeks were randomly assigned to control (CON and tail suspension (SUS group (9 each. Rats with tail suspension for 28 days were adopted as the animal model to simulate microgravity. Caudal arterial pressure and heart rate of rats were measured every 3 hours. The circadian difference of abdominal aorta contraction was measured by aortic ring test. Western blotting was performed to determine and compare the protein expression level of clock genes such as Per2 (Period2, Bmal1 (Aryl hydrocarbon receptor nuclear translocatorlike and dbp (D element binding protein in suprachiasmatic nucleus (SCN and abdominal aorta of rats in CON and SUS group at different time points. Results  Compared with CON group, the caudal arterial pressure, both systolic and diastolic pressure, decreased significantly and the diurnal variability disappeared, meanwhile the heart rate increased obviously and also the diurnal variability disappeared in rats of SUS group. Compared with CON group, the contraction reactivity of abdominal aorta decreased with disappearence of the diurnal variability, and also the clock genes expression in SCN and abdominal aorta showed no diurnal variability in rats of SUS group. Conclusion  Simulated microgravity may lead to circadian rhythm disorders in rats' cardiovascular system, which may be associated with the changes of the clock genes expression. DOI: 10.11855/j.issn.0577-7402.2016.04.06

  3. Comparison of arterial pressure and plethysmographic waveform-based dynamic preload variables in assessing fluid responsiveness and dynamic arterial tone in patients undergoing major hepatic resection

    NARCIS (Netherlands)

    Vos, J. J.; Kalmar, A. F.; Struys, M. M. R. F.; Wietasch, J. K. G.; Hendriks, H. G. D.; Scheeren, T. W. L.

    2013-01-01

    Dynamic preload variables to predict fluid responsiveness are based either on the arterial pressure waveform (APW) or on the plethysmographic waveform (PW). We compared the ability of APW-based variations in stroke volume (SVV) and pulse pressure (PPV) and of PW-based plethysmographic variability in

  4. Comparison of arterial pressure and plethysmographic waveform-based dynamic preload variables in assessing fluid responsiveness and dynamic arterial tone in patients undergoing major hepatic resection

    NARCIS (Netherlands)

    Vos, J. J.; Kalmar, A. F.; Struys, M. M. R. F.; Wietasch, J. K. G.; Hendriks, H. G. D.; Scheeren, T. W. L.

    Dynamic preload variables to predict fluid responsiveness are based either on the arterial pressure waveform (APW) or on the plethysmographic waveform (PW). We compared the ability of APW-based variations in stroke volume (SVV) and pulse pressure (PPV) and of PW-based plethysmographic variability

  5. Comparison of arterial pressure and plethysmographic waveform-based dynamic preload variables in assessing fluid responsiveness and dynamic arterial tone in patients undergoing major hepatic resection

    NARCIS (Netherlands)

    Vos, J. J.; Kalmar, A. F.; Struys, M. M. R. F.; Wietasch, J. K. G.; Hendriks, H. G. D.; Scheeren, T. W. L.

    2013-01-01

    Dynamic preload variables to predict fluid responsiveness are based either on the arterial pressure waveform (APW) or on the plethysmographic waveform (PW). We compared the ability of APW-based variations in stroke volume (SVV) and pulse pressure (PPV) and of PW-based plethysmographic variability in

  6. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    Science.gov (United States)

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  7. A comparison of noninvasive blood pressure measurement on the wrist with invasive arterial blood pressure monitoring in patients undergoing bariatric surgery.

    Science.gov (United States)

    Hager, Helmut; Mandadi, Goutham; Pulley, Debra; Eagon, J Chris; Mascha, Edward; Nutter, Benjamin; Kurz, Andrea

    2009-06-01

    In morbidly obese patients, oscillometric blood pressure measurements with an upper-arm cuff are often difficult to perform. The alternative method, invasive blood pressure monitoring, can be difficult to place and is associated with risks. A wrist-mounted blood pressure-monitoring device, the Vasotrac, provides accurate blood pressure measurements in lean patients. Even in the obese, wrist morphology remains relatively unchanged. We thus assessed the degree to which blood pressure measurements with the Vasotrac on the wrist and cuff measurements agree with invasive arterial blood pressure monitoring. We evaluated 22 morbidly obese patients undergoing bariatric surgery lasting 3.8+/-1.1 h. Intraoperative blood pressure was simultaneously measured using the Vasotrac mounted on one wrist; an arterial catheter was inserted in the opposite radial artery, and an oscillometric cuff was positioned on the upper arm. Preoperative patient comfort was evaluated on a scale from 1 to 10, with 10 being most uncomfortable, just after the first oscillometric cuff inflation. Values from the Vasotrac and arterial catheter were recorded at 5-s intervals. Bias, precision, and clinically acceptable agreement were calculated between the two continuous monitoring devices and between the arterial catheter and the cuff measurements, with the arterial catheter providing the reference value. The patients' age was 44.3+/-9.5 years (mean+/-SD), body mass index was 66.7+/-13.8 kg/m2, and arm circumference was 48.6+/-7.5 cm. Patients found the Vasotrac more comfortable than the oscillometric device [1.7+/-1.8 vs 5.3+/-0.5 (P=0.009)]. A total of 40,411 pairs of values from the Vasotrac and arterial catheter were recorded. Lin's concordance correlation coefficient (95% CI) for mean arterial blood pressure measured between the arterial line and the Vasotrac was 0.74 (0.67, 0.82). The bias (mean error) was -0.25 mmHg; however, the Bland-Altman limits where 95% of individual pressure differences are

  8. Severe hypovitaminosis D in chronic kidney disease: association with blood pressure and coronary artery calcification.

    Science.gov (United States)

    Pillar, Roberta; G Lopes, Miriam Ghedini; Rocha, Lillian Andrade; Cuppari, Lilian; Carvalho, Aluízio B; Draibe, Sérgio A; Canziani, Maria Eugênia F

    2013-05-01

    Hypovitaminosis D occurs early in the course of chronic kidney disease (CKD), and its association with cardiovascular morbidity and mortality is well known. In this study, we aimed to evaluate whether the degree of hypovitaminosis D may differently affect blood pressure (BP) and coronary artery calcification (CAC) in nondialyzed CKD patients. This study included 80 CKD patients with a creatinine clearance between 15 and 60 ml/min/1.73 m(2) and serum 25 hydroxivitamin D [25(OH)D] level hypovitaminosis D, were defined according to the median 25(OH)D value. Patients with severe hypovitaminosis D [25(OH)D hypovitaminosis D [25(OH)D >17.2 ng/ml; M-group]. No differences were found between the S and M-group in terms of diastolic BP and the presence of coronary calcification. In the multiple linear regression analysis, severe hypovitaminosis D was a predictor of 24-h, daytime and nighttime BP after controlling for a number of confounders. The severity of hypovitaminosis D was associated with increased BP in nondialyzed CKD patients. The degree of hypovitaminosis D was not related to CAC, which was equally elevated in both the severe and mild hypovitaminosis D groups.

  9. Leave-one-out prediction error of systolic arterial pressure time series under paced breathing

    CERN Document Server

    Ancona, N; Marinazzo, D; Nitti, L; Pellicoro, M; Pinna, G D; Stramaglia, S

    2004-01-01

    In this paper we show that different physiological states and pathological conditions may be characterized in terms of predictability of time series signals from the underlying biological system. In particular we consider systolic arterial pressure time series from healthy subjects and Chronic Heart Failure patients, undergoing paced respiration. We model time series by the regularized least squares approach and quantify predictability by the leave-one-out error. We find that the entrainment mechanism connected to paced breath, that renders the arterial blood pressure signal more regular, thus more predictable, is less effective in patients, and this effect correlates with the seriousness of the heart failure. The leave-one-out error separates controls from patients and, when all orders of nonlinearity are taken into account, alive patients from patients for which cardiac death occurred.

  10. Predicting electrocardiogram and arterial blood pressure waveforms with different Echo State Network architectures.

    Science.gov (United States)

    Fong, Allan; Mittu, Ranjeev; Ratwani, Raj; Reggia, James

    2014-01-01

    Alarm fatigue caused by false alarms and alerts is an extremely important issue for the medical staff in Intensive Care Units. The ability to predict electrocardiogram and arterial blood pressure waveforms can potentially help the staff and hospital systems better classify a patient's waveforms and subsequent alarms. This paper explores the use of Echo State Networks, a specific type of neural network for mining, understanding, and predicting electrocardiogram and arterial blood pressure waveforms. Several network architectures are designed and evaluated. The results show the utility of these echo state networks, particularly ones with larger integrated reservoirs, for predicting electrocardiogram waveforms and the adaptability of such models across individuals. The work presented here offers a unique approach for understanding and predicting a patient's waveforms in order to potentially improve alarm generation. We conclude with a brief discussion of future extensions of this research.

  11. The relationship between rheumatoid factor levels and coronary artery lesion complexity and severity in patients with stable coronary artery disease

    Science.gov (United States)

    Avcı, Anıl; Açar, Göksel; Fidan, Serdar; Öcal, Lütfi; Bulut, Mustafa; Tellice, Muhammed; Akçakoyun, Mustafa; Pala, Selçuk; Esen, Ali Metin

    2015-01-01

    Introduction The relation between serum rheumatoid factor levels and the extent, severity, and complexity of coronary artery disease has not been adequately studied. Aim Therefore, we assessed the relationship between the severity of coronary artery disease assessed by SYNTAX score and serum rheumatoid factor levels in patients with stable coronary artery disease. Material and methods We enrolled 268 consecutive patients who underwent coronary angiography. Patients with acute coronary syndrome and chronic immune disorders were excluded. Baseline serum rheumatoid factor levels were measured and the SYNTAX score was calculated from the study population. Results Patients were divided into two groups. Group 1 was defined as low SYNTAX score 22. Serum rheumatoid factor levels were significantly higher in the intermediate and high-SYNTAX score group than in the low-SYNTAX score group (16.4 ±9 IU/mlvs. 11.36 ±5 IU/ml, p < 0.001). Also, there was a significant correlation between rheumatoid factor and CRP levels with the SYNTAX score r = 0.411; p < 0.001 and r = 0.275; p < 0.001, respectively. On multivariate linear regression analysis, rheumatoid factor (β = 0.101, p < 0.001) was an independent risk factor for intermediate and high SYNTAX score in patients with stable coronary artery disease. In receiver operator characteristic curve analysis, optimal cut-off value of rheumatoid factor to predict high SYNTAX score was found to be 10.5 IU/ml, with 69% sensitivity and 61% specificity. Conclusions The rheumatoid factor level was independently associated with the extent, complexity, and severity of coronary artery disease assessed by SYNTAX score in patients with stable coronary artery diseases. PMID:25848367

  12. Atlas vertebra realignment and achievement of arterial pressure goal in hypertensive patients: a pilot study.

    Science.gov (United States)

    Bakris, G; Dickholtz, M; Meyer, P M; Kravitz, G; Avery, E; Miller, M; Brown, J; Woodfield, C; Bell, B

    2007-05-01

    Anatomical abnormalities of the cervical spine at the level of the Atlas vertebra are associated with relative ischaemia of the brainstem circulation and increased blood pressure (BP). Manual correction of this mal-alignment has been associated with reduced arterial pressure. This pilot study tests the hypothesis that correcting mal-alignment of the Atlas vertebra reduces and maintains a lower BP. Using a double blind, placebo-controlled design at a single center, 50 drug naïve (n=26) or washed out (n=24) patients with Stage 1 hypertension were randomized to receive a National Upper Cervical Chiropractic (NUCCA) procedure or a sham procedure. Patients received no antihypertensive meds during the 8-week study duration. The primary end point was changed in systolic and diastolic BP comparing baseline and week 8, with a 90% power to detect an 8/5 mm Hg difference at week 8 over the placebo group. The study cohort had a mean age 52.7+/-9.6 years, consisted of 70% males. At week 8, there were differences in systolic BP (-17+/-9 mm Hg, NUCCA versus -3+/-11 mm Hg, placebo; P<0.0001) and diastolic BP (-10+/-11 mm Hg, NUCCA versus -2+/-7 mm Hg; P=0.002). Lateral displacement of Atlas vertebra (1.0, baseline versus 0.04 degrees week 8, NUCCA versus 0.6, baseline versus 0.5 degrees , placebo; P=0.002). Heart rate was not reduced in the NUCCA group (-0.3 beats per minute, NUCCA, versus 0.5 beats per minute, placebo). No adverse effects were recorded. We conclude that restoration of Atlas alignment is associated with marked and sustained reductions in BP similar to the use of two-drug combination therapy.

  13. Re-evaluation of Pre-pump Arterial Pressure to Avoid Inadequate Dialysis and Hemolysis: Importance of Prepump Arterial Pressure Monitoring in Hemodialysis Patients.

    Science.gov (United States)

    Shibata, Eriko; Nagai, Kojiro; Takeuchi, Risa; Noda, Yasuhiro; Makino, Tomomi; Chikata, Yusuke; Hann, Michael; Yoshimoto, Sakiya; Ono, Hiroyuki; Ueda, Sayo; Tamaki, Masanori; Murakami, Taichi; Matsuura, Motokazu; Abe, Hideharu; Doi, Toshio

    2015-07-01

    Prepump arterial pressure (PreAP) is monitored to avoid generating excessive negative pressure. The National Kidney Foundation K/DOQI clinical practice guidelines for vascular access recommend that PreAP should not fall below -250 mm Hg because excessive negative PreAP can lead to a decrease in the delivery of blood flow, inadequate dialysis, and hemolysis. Nonetheless, these recommendations are consistently disregarded in clinical practice and pressure sensors are often removed from the dialysis circuit. Thus far, delivered blood flow has been reported to decrease at values more negative than -150 mm Hg of PreAP. These values have been analyzed by an ultrasonic flowmeter and not directly measured. Furthermore, no known group has evaluated whether PreAP-induced hemolysis occurs at a particular threshold. Therefore, the aim of this study was to clarify the importance of PreAP in the prediction of inadequate dialysis and hemolysis. By using different diameter needles, human blood samples from healthy volunteers were circulated in a closed dialysis circuit. The relationship between PreAP and delivered blood flow or PreAP and hemolysis was investigated. We also investigated the optimal value for PreAP using several empirical monitoring methods, such as a pressure pillow. Our investigation indicated that PreAP is a critical factor in the determination of delivered blood flow and hemolysis, both of which occured at pressure values more negative than -150 mm Hg. With the exception of direct pressure monitoring, commonly used monitoring methods for PreAP were determined to be ineffective. We propose that the use of a vacuum monitor would permit regular measurement of PreAP. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  14. Relative value of pressures and volumes in assessing fluid responsiveness after valvular and coronary artery surgery.

    Science.gov (United States)

    Breukers, Rose-Marieke B G E; Trof, Ronald J; de Wilde, Rob B P; van den Berg, Paul C M; Twisk, Jos W R; Jansen, Jos R C; Groeneveld, Johan

    2009-01-01

    Cardiac function may differ after valvular (VS) and coronary artery (CAS) surgery and this may affect assessment of fluid responsiveness. The aim of the study was to compare VS and CAS in the value of cardiac filling pressures and volumes herein. There were eight consecutive patients after VS and eight after CAS, with femoral and pulmonary artery catheters in place. In each patient, five sequential fluid loading steps of 250 ml of colloid each were done. We measured central venous pressure (CVP), pulmonary artery occlusion pressure (PAOP) and, by transpulmonary thermodilution, cardiac index (CI) and global end-diastolic (GEDVI) and intrathoracic blood volume (ITBVI) indices. Fluid responsiveness was defined by a CI increase >5% or >10% per step. Global ejection fraction was lower and PAOP was higher after VS than CAS. In responding steps after VS (n=9-14) PAOP and volumes increased, while CVP and volumes increased in responding steps (n=12-19) after CAS. Baseline PAOP was lower in responding steps after VS only. Hence, baseline PAOP as well as changes in PAOP and volumes were of predictive value after VS and changes in CVP and volumes after CAS, in receiver operating characteristic curves. After VS, PAOP and volume changes equally correlated to CI changes. After CAS, only changes in CVP and volumes correlated to those in CI. While volumes are equally useful in monitoring fluid responsiveness, the predictive and monitoring value of PAOP is greater after VS than after CAS. In contrast, the CVP is of similar value as volume measurements in monitoring fluid responsiveness after CAS. The different value of pressures rather than of volumes between surgery types is likely caused by systolic left ventricular dysfunction in VS. The study suggests an effect of systolic cardiac function on optimal parameters of fluid responsiveness and superiority of the pulmonary artery catheter over transpulmonary dilution, for haemodynamic monitoring of VS patients.

  15. External iliac artery injury secondary to indirect pressure wave effect from gunshot wound

    Institute of Scientific and Technical Information of China (English)

    Eugene Ng; Andrew MTL.Choong

    2016-01-01

    In patients presenting with gunshot wounds,a high clinical suspicion of injury to vasculature and viscera remote from the projectile track is paramount.We present a case of a 17 year old male who sustained a gunshot wound to his abdomen and subsequently developed a right external iliac artery contusion requiring surgery as an indirect effect of the pressure wave from the bullet.

  16. Sex Comparisons in Muscle Sympathetic Nerve Activity and Arterial Pressure Oscillations During Progressive Central Hypovolemia

    Science.gov (United States)

    2015-01-01

    sympathetic activity in humans. Am. J. Physiol. 287:H1658–H1662. Convertino, V. A. 1996. Clinical aspects of the control of plasma volume at microgravity and...standards of measurement, physiological interpretation, and clinical use. Circulation 93:1043–1065. Ichinose, M., M. Saito, A. Kitano, K. Hayashi, N...G. Huang, S. A. Smith, R. Zhang, and K. J. Formes. 2003. Aging and arterial blood pressure variability during orthostatic challenge. Gerontology 49

  17. Effect of Algerian Varieties Dates on Glycemic, Arterial Blood Pressure and Satiety Responses

    OpenAIRE

    Gourchala Freha, Mihoub Fatma, Derradj Meriem, Henchiri Cherifa

    2016-01-01

    The purpose of our study is to determine the Glycemic Indexes (GIs)of three Algerians varieties of dates in healthy subjects, evaluate the satiety and effect on arterial pressure after their consumption. We have first documented the chemical composition of the dates. 10 healthy subjects consumed the dates (carbohydrates content of 50 g) in order to determine the GIs. The responses of glycaemia were monitored during two hours after the dates taking and compared to the reference glucose. In a r...

  18. The effects of epinine on arterial blood pressure and regional vascular resistances in anesthetized rats.

    Science.gov (United States)

    Martínez-Mir, I; Palop, V; Morales-Olivas, F J; Estañ, L; Rubio, E

    1998-07-01

    1. We carried out experiments in anesthetized rats to study the hemodynamic effects of intravenous injections of epinine. 2. Epinine (1-320 micrograms/kg) produced a biphasic effect on mean arterial blood pressure (n = 30). At doses lower than 40 micrograms/kg, arterial blood pressure decreased (by as much as 21.5 +/- 3.4%), though at higher doses it increased dose dependently (by as much as 73.2 +/- 14.5%). Epinine also produced bradicardia in a dose-dependent manner (by as much as 26.4 +/- 4.9%). Sulpiride (100 micrograms/kg) suppressed the hypotensive effect of epinine but did not change the hypertensive effect. In the presence of prazosin (1,000 micrograms/kg), arterial blood pressure remained significantly decreased at all doses of epinine. Neither sulpiride nor prazosin changed the bradycardic effect of epinine. 3. Prazosin produced a significant decrease in renal vascular resistance. Epinine (5 micrograms/kg) after prazosin reverted the effects of prazosin in renal vascular resistance, without any significant modification in the renal blood flows. However, 20 micrograms/kg epinine increased the renal vascular resistances and, moreover, produced a significant decrease in the blood flows of both kidneys. Neither prazosin nor epinine produced modifications in the intestinal vascular bed. 4. Although epinine possesses significant dopamine and alpha-adrenergic activities that are involved in the biphasic effect of the agent on mean arterial blood pressure in anesthetized rats, in the presence of prazosin, it is not possible to manifest dopaminergic activity involved in the increase in renal or mesenteric blood flow; this may be due to the low tone of the vascular wall induced by the alpha-adrenergic antagonist, though an alpha 2-activity cannot be discarded.

  19. Fourier Analysis of Peripheral Blood Pressure and Flow in Intraoperative Assessment of Infrainguinal Arterial Reconstructions

    Directory of Open Access Journals (Sweden)

    Cheshmedzhiev Mihail V.

    2014-08-01

    Full Text Available AIM: To assess infrainguinal arterial reconstructions by intraoperative flowmetry under the distal anastomosis using a fast Fourier transformation; calculate and compare the amplitude ratios of peripheral arterial blood pressure and volume flow before and after drug-induced vasodilation of occluded bypass grafts and bypass grafts that have been patent at least for 1 year. To find what magnitude of the change of these ratios indicate a long-term patency of the bypass grafting. PATIENTS AND METHODS: We compared the results of the intraoperative flowmetry tests of 97 patients with infrainguinal arterial reconstructions. The patients were divided into two groups based on the graft status: the grafts in 49 patients were patent for at least a year, and 48 patients had failed bypass. We used a fast Fourier transform (FFT of the pressure and blood flow waves and compared the ratios of their amplitudes before and after administration of a vasodilator drug into the graft. Comparing the ratios obtained before and those after administration of the drug we quantified their change in each group and analysed them. RESULTS: After a drug-induced vasodilation, the blood pressure and flow amplitude ratios for the group with compromised reconstructions were less than 1.9 times smaller than those before drug infusion, while for the group with bypass grafts that had been functional for at least 12 months the ratios declined by more than 1.9≈2 times. CONCLUSION: The magnitude of the change of amplitude ratios of the peripheral pressure and volume flow after drug-induced vasodilation can be used to make an assessment of the bypass graft and the distal arterial segment.

  20. Heart period and blood pressure characteristics in splanchnic arterial occlusion shock-induced collapse.

    Science.gov (United States)

    Aletti, Federico; Gambarotta, Nicolò; Penn, Alexander H; Ferrario, Manuela; Schmid-Schönbein, Geert W

    2017-02-01

    The nature of hemodynamic instability typical of circulatory shock is not well understood, but an improved interpretation of its dynamic features could help in the management of critically ill patients. The objective of this work was to introduce new metrics for the analysis of arterial blood pressure (ABP) in order to characterize the risk of catastrophic outcome in splanchnic arterial occlusion (SAO) shock. Continuous ABP (fs = 1 kHz) was measured in rats during experimental SAO shock, which induced a fatal pressure drop (FPD) in ABP. The FPD could either be slow (SFPD) or fast (FFPD), with the latter causing cardiovascular collapse. Time series of mean arterial pressure, systolic blood pressure and heart period were derived from ABP. The sample asymmetry-based algorithm Heart Rate Characteristics was adapted to compute the Heart Period Characteristics (HPC) and the Blood Pressure Characteristics (BPC). Baroreflex sensitivity (BRS) was assessed by means of a bivariate model. The approach to FPD of the animals who collapsed (FFPD) was characterized by higher BRS in the low frequency band versus SFPD animals (0.36 ± 0.15 vs. 0.19 ± 0.12 ms/mmHg, p value = 0.0196), bradycardia as indicated by the HPC (0.76 ± 0.57 vs. 1.94 ± 1.27, p value = 0.0179) and higher but unstable blood pressure as indicated by BPC (3.02 ± 2.87 vs. 1.47 ± 1.29, p value = 0.0773). The HPC and BPC indices demonstrated promise as potential clinical markers of hemodynamic instability and impending cardiovascular collapse, and this animal study suggests their test in data from intensive care patients.

  1. Heel ulcers - Pressure ulcers or symptoms of peripheral arterial disease? An exploratory matched case control study.

    Science.gov (United States)

    Twilley, Heidi; Jones, Sarahjane

    2016-05-01

    To investigate the relationship between pressure ulcers of the heel and peripheral arterial disease (PAD) and determine the feasibility of conducting a statistically powered matched case control study. Evidence indicates a relationship between chronic leg ulcers and vascular disease. The relationship between pressure ulcers of the heel and vascular disease is less well established. A matched case control study. Data were collected between March 2014 and January 2015. 15 patients identified as having a grade 2, 3 or 4 pressure ulcer of the heel were compared with 15 matched controls without pressure ulcers of the heel. The primary clinical outcome measure was the ankle brachial pressure index (ABPI), where an ABPI 1.3 was considered clinically indicative of PAD. The primary feasibility outcome measure was the rate of recruitment. Eighty seven patients were reported as having foot and heel ulcers; 36 of whom were identified as having pressure ulcers of the heel, 15 (42%) of whom were recruited to the study. Patients presenting with pressure ulcers of the heel were significantly more likely to simultaneously have previously undiagnosed PAD compared with age, gender and ethnicity matched controls without pressure ulcers of the heel (odds ratio: 11, 95% confidence interval 1.99-60.57). The formation of pressure ulcers of the heel could, in some patients, be related to the presence of PAD rather than a consequence of poor quality care. Healthcare professionals should assess the patient to exclude or confirm PAD. Copyright © 2016 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  2. Oxidative stress mediated arterial dysfunction in patients with obstructive sleep apnoea and the effect of continuous positive airway pressure treatment

    Directory of Open Access Journals (Sweden)

    Del Ben Maria

    2012-07-01

    Full Text Available Abstract Background Several studies suggest an increase of oxidative stress and a reduction of endothelial function in obstructive sleep apnoea syndrome (OSAS. We assessed the association between OSAS, endothelial dysfunction and oxidative stress. Further aim was to evaluate the effect of nasal continuous positive airway pressure (nCPAP on oxidative stress and arterial dysfunction. Methods We studied 138 consecutive patients with heavy snoring and possible OSAS. Patients underwent unattended overnight home polysomnography. Ten patients with severe OSAS were revaluated after 6 months of nCPAP therapy. To assess oxidative stress in vivo, we measured urinary 8-iso-PGF2α and serum levels of soluble NOX2-derived peptide (sNOX2-dp. Serum levels of nitrite/nitrate (NOx were also determined. Flow-mediated brachial artery dilation (FMD was measured to asses endothelial function. Results Patients with severe OSAS had higher urinary 8-iso-PGF2α (p Conclusions The results of our study indicate that patients with OSAS and cardiometabolic comorbidities have increased oxidative stress and arterial dysfunction that are partially reversed by nCPAP treatment.

  3. Effects of terlipressin on systolic pulmonary artery pressure of patients with liver cirrhosis:An echocardiographic assessment

    Institute of Scientific and Technical Information of China (English)

    Engin Altintas; Necdet Akkus; Ramazan Gen; M. Rami Helvaci; Orhan Sezgin; Dilek Oguz

    2004-01-01

    AIM: Portopulmonary hypertension is a serious complication of chronic liver disease. Our aim was to search into the effect of terlipressin on systolic pulmonary artery pressure among cirrhotic patients.METHODS: Twelve patients (6 males and 6 females) with liver cirrhosis were recruited in the study. Arterial blood gas samples were obtained in sitting position at rest. Contrast enhanced echocardiography and measurements of systolic pulmonary artery pressure were performed before and after the intravenous injection of 2 mg terlipressin.RESULTS: Of 12 patients studied, the contrast enhanced echocardiography was positive in 5, and the positive findings in contrast enhanced echocardiography were reversed to normal in two after terlipressin injection. The mean systolic pulmonary artery pressure was 25.5±3.6 mmHg before terlipressin injection, and was 22.5±2.5 mmHg after terlipressin (P=0.003). The systolic pulmonary artery pressure was above 25 mmHg in seven of these 12 patients.After the terlipressin injection, systolic pulmonary artery pressure was <25 mmHg in four of these cases (58.3% vs 25%, P=0.04).CONCLUSION: Terlipressin can decrease the systolic pulmonary artery pressure in patients with liver cirrhosis.

  4. Vasopressin contributes to maintenance of arterial blood pressure in dehydrated baboons.

    Science.gov (United States)

    Ryan, K L; Thornton, R M; Proppe, D W

    1989-02-01

    This study primarily sought to determine whether the role of vasopressin (VP) in maintenance of arterial blood pressure is enhanced in awake, chronically instrumented baboons after 68-72 h of dehydration. This question was approached by pharmacologically blocking vasopressin V1-receptors in euhydrated and dehydrated baboons with or without a normally functioning renin-angiotensin system (RAS). VP blockade during dehydration produced a rapidly occurring (within 5 min), statistically significant (P less than 0.05) decrease in mean arterial pressure (MAP) of 5 +/- 1 mmHg in the RAS-intact condition and an identical decline in MAP (5 +/- 1 mmHg) during blockade of the RAS by captopril, an angiotensin I-converting enzyme inhibitor. At 15 min after induction of VP blockade, heart rate was elevated by 9 +/- 2 beats/min in the RAS-intact condition and by 20 +/- 5 beats/min in the RAS-blocked condition. In addition, VP blockade in the dehydrated state produced small and equal increases in hindlimb vascular conductance in RAS-intact and RAS-blocked conditions. None of these cardiovascular changes were produced by VP blockade in the euhydrated state. RAS blockade produced modest declines in MAP in both hydration states, but the fall was larger by 7 +/- 4 mmHg in the dehydrated state. Thus both VP and the RAS contribute to the maintenance of arterial blood pressure during dehydration in the conscious baboon.

  5. Influence of a history of arterial hypertension and pretreatment blood pressure on the effect of angiotensin converting enzyme inhibition after acute myocardial infarction. Trandolapril Cardiac Evaluation Study

    DEFF Research Database (Denmark)

    Gustafsson, F; Køber, L; Torp-Pedersen, C

    1998-01-01

    inhibition after AMI complicated by left ventricular dysfunction may be of particular importance in patients with a history of arterial hypertension or a relatively high pretreatment blood pressure. However, further investigations are necessary to establish the clinical impact of these results.......OBJECTIVE: To evaluate the influence of a history of arterial hypertension and the level of pretreatment blood pressure on the efficacy of the angiotensin converting enzyme (ACE) inhibitor trandolapril on mortality and morbidity in patients with acute myocardial infarction (AMI) and left...... for a broad spectrum of potential confounders. Also, benefit from ACE inhibition increased with increasing blood pressure at the time of randomization. Significant interactions between benefit from ACE inhibition and hypertension history, and systolic and diastolic blood pressure were found. CONCLUSION: ACE...

  6. Serum free thyroxine levels are positively associated with arterial stiffness in the SardiNIA study.

    Science.gov (United States)

    Delitala, Alessandro P; Orrù, Marco; Filigheddu, Fabiana; Pilia, Maria Grazia; Delitala, Giuseppe; Ganau, Antonello; Saba, Pier Sergio; Decandia, Federica; Scuteri, Angelo; Marongiu, Michele; Lakatta, Edward G; Strait, James; Cucca, Francesco

    2015-04-01

    Thyroid dysfunction may accelerate atherosclerosis. Aortic pulse wave velocity (PWV) is an early index of arterial stiffness and an important risk factor for cardiovascular disease and might therefore be linked to changes in thyroid activity. We investigated the relationship between thyroid function and carotid-femoral PWV, as an index of arterial stiffness. Cross-sectional cohort study. Participants from the SardiNIA study. Those being treated for thyroid diseases were excluded, yielding a sample of 5875 aged 14-102. Clinical parameters, blood tests including serum TSH and serum FT4, and carotid-femoral PWV were measured. After adjusting for confounders, a direct and linear association between FT4 and PWV was shown (multiple regression analysis). The model containing age, mean blood pressure, body mass index, heart rate, FT4, hypertension, diabetes and dyslipidaemia accounted for 55% of the variation in PWV. Like several other known risk factors, serum FT4 levels are associated with carotid-femoral PWV, suggesting that high FT4 levels have a detrimental effect on aortic stiffness and may contribute to ageing process of the vascular system. This finding may help to understand the pathogenesis of cardiovascular disease and contribute to improve prevention therapy. © 2014 John Wiley & Sons Ltd.

  7. Healing of ulcers on the feet correlated with distal blood pressure measurements in occlusive arterial disease

    DEFF Research Database (Denmark)

    Holstein, P; Lassen, N A

    1980-01-01

    The frequency of healing in subchronic ulcers in 66 feet in 62 patients with arterial occlusive disease was correlated with the systolic digital blood pressure (SDBP) and the systolic ankle blood pressure (SABP), both measured with a strain gauge, and with the skin perfusion pressure on the heel...... of healing correlated significantly with the three distal blood pressure parameters investigated, the closest correlation being with the SDBP measured at the final examination, i.e. just after healing of the ulcer or just before an inevitable major amputation. Of the 22 cases with SDBP below 20 mmHg only two...... (SPPH) as measured with a photocell. Thirty-two patients (35 feet with ulcerations) had diabetes mellitus. The treatment was conservative. In 42 feet the ulcers healed after an average period of 5.8 months; in 24 feet major amputation became necessary after an average of 4.3 months. The frequency...

  8. High Central Aortic Rather than Brachial Blood Pressure is Associated with Carotid Wall Remodeling and Increased Arterial Stiffness in Childhood.

    Science.gov (United States)

    Peluso, Gonzalo; García-Espinosa, Victoria; Curcio, Santiago; Marota, Marco; Castro, Juan; Chiesa, Pedro; Giachetto, Gustavo; Bia, Daniel; Zócalo, Yanina

    2017-03-01

    In adults, central blood pressure (cBP) is reported to associate target organ damages (TODs) rather than peripheral blood pressure (pBP). However, data regarding the association of pre-clinical TODs with cBP and pBP in pediatric populations are scarce. To evaluate in children and adolescents the importance of cBP and pBP levels, in terms of their association with hemodynamic and vascular changes. 315 subjects [age (mean/range) 12/8-18 years] were included. pBP (oscillometry, Omron-HEM433INT and Mobil-O-Graph), cBP levels and waveforms (oscillometry, Mobil-O-Graph; applanation tonometry, SphygmoCor), aortic wave reflection-related parameters, carotid intima-media thickness (CIMT) and carotid (elastic modulus, stiffness-index) and aortic stiffness (carotid-femoral pulse wave velocity, PWV). Four groups were defined considering pBP and cBP percentiles (th): cBP ≥90th, cBP blood pressure (cBP or pBP). Subgroups were matched for anthropometric and cardiovascular risk factors (propensity matching-score). Subjects with high cBP showed a worse cardiovascular risk profile in addition to worse peripheral hemodynamic conditions. The CIMT, carotid and aortic stiffness levels were also higher in those subjects. CIMT and carotid stiffness remained statistically higher when subjects were matched for pBP and other cardiovascular risk factors. There were no differences in arterial properties when subjects were analyzed (compared) considering similar pBP levels, during normal and high cBP conditions. Compared with pBP, the cBP levels show a greater association with vascular alterations (high CIMT and arterial stiffness), in children and adolescents.

  9. Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery

    Institute of Scientific and Technical Information of China (English)

    LU Jia-kai; ZHU Chen; JING He; WANG Yi-jun; QING En-ming

    2012-01-01

    Background For patients undergoing off-pump coronary artery bypass grafting (OPCABG),it is important to establish a hemodynamic monitoring system to obtain powerful parameters for better intraoperative treatment.This study aimed to observe the clinical feasibility of artedal pressure-based cardiac output (APCO) for cardiac output (CO) monitoring and to evaluate the correlation between APCO and pulmonary artery catheter (PAC) for CO measurement for patients undergoing OPCABG intraoperatively.Methods Fifty patients of Amedcan Society of Anaesthesiologists (ASA) classification Ⅱ-Ⅲ,undergoing elective OPCABG at Beijing Anzhen Hospital were randomly enrolled into this study.All patients were assigned to CO monitoring by PAC and APCO simultaneously.Patients with pacemaker,severe valvular heart disease,left ventdcular ejection fraction (EF) <40%,cardiac arrhythmias,peripheral vascular disease,application of intra-aortic balloon pump (IABP) and emergent diversion to cardiac pulmonary bypass were excluded.The radial artery wavaform was analyzed to estimate the stroke volume (SV) and heart rate (HR) continuously.CO was calculated as SV x HR; other derived parameters were cardiac index (CI),stroke volume index (SVI),systemic vascular resistance (SVR),and systemic vascular resistance index (SVRI).PAC was placed via right internal jugular vein and the correct position was confirmed by PAC waveforms.Continuous cardiac output (CCO),CI and other hemodynamic parameters were monitored at following 5 time points:immediate after anesthesia induction (baseline value),anastomosis of left intemal mammary artery to left anterior descending artery (LAD),anastomosis of left circumflex (LCX),anastomosis of posterior descending artery (PDA) and immediate after sternal closure.Results In the 50 patients,preoperative echocardiography measured left ventricular EF was (52.8±11.5)%,and 35 patients (70%) showed regional wall motion abnormalities.The correlation coefficient of CO

  10. Morning rise of blood pressure and subcutaneous small resistance artery structure.

    Science.gov (United States)

    Rizzoni, Damiano; Porteri, Enzo; Platto, Caterina; Rizzardi, Nicola; De Ciuceis, Carolina; Boari, Gianluca E M; Muiesan, Maria Lorenza; Salvetti, Massimo; Zani, Francesca; Miclini, Marco; Paiardi, Silvia; Castellano, Maurizio; Rosei, Enrico Agabiti

    2007-08-01

    It has been previously demonstrated that the morning rise (MoR) of blood pressure (BP) may predict major cardiovascular events in hypertensive patients. Structural alterations of small resistance arteries, as evaluated by the tunica media to internal lumen ratio (M/L) of subcutaneous small resistance arteries, may also predict cardiovascular events. Because an increased M/L may amplify the effect of hypertensive stimuli, the present study aimed to evaluate the possible relationships between MoR and M/L in a population of hypertensive patients. Sixty-four patients with essential hypertension were included in the present study. All patients were submitted to a biopsy of subcutaneous fat. Small resistance arteries were dissected and mounted on an isometric myograph, and the M/L was measured. In addition, MoR was calculated from ambulatory blood pressure monitoring (ABPM) according to four previously published different methods (MoR1 to MoR4). A statistically significant correlation was observed between M/L and MoR1 (r = 0.52, P < 0.001), MoR2 (r = 0.32, P < 0.01), MoR3 (r = 0.25, P < 0.05) and MoR4 (r = 0.27, P < 0.05), as well as between internal diameter of subcutaneous small arteries and MoR1 (r = -0.45, P < 0.001) and MoR2 (r = -0.28, P < 0.05). Our results indicate that subcutaneous small artery structure is related to MoR, possibly because an altered vascular structure may amplify BP changes or, vice versa, because a greater MoR may further damage peripheral vasculature.

  11. Pulse-pressure variation predicts fluid responsiveness during heart displacement for off-pump coronary artery bypass surgery.

    Science.gov (United States)

    Lee, Jong-Hwan; Jeon, Yunseok; Bahk, Jae-Hyon; Gil, Nam-Su; Kim, Ki-Bong; Hong, Deok Man; Kim, Hyun Joo

    2011-12-01

    The aim of this study was to evaluate the ability of pulse-pressure variation to predict fluid responsiveness during heart displacement for off-pump coronary artery bypass surgery using receiver operating characteristic analysis. A prospective study. A clinical study in a single cardiac anesthesia institution. Thirty-five patients undergoing elective off-pump coronary artery bypass surgery. Central venous pressure, pulmonary arterial occlusion pressure, pulse-pressure variation, and cardiac index were measured 5 minutes after revascularization of the left anterior descending coronary artery and before heart displacement. Immediately after heart displacement for revascularization of the left circumflex artery, and 10 minutes after fluid loading with hydroxyethyl starch 6% (10 mL/kg) during heart displacement, the measurements were repeated. Patients whose cardiac indices increased by ≥15% from fluid loading were defined as responders. After heart displacement, only pulse-pressure variation showed significant difference between the responders and nonresponders (13.48 ± 6.42 v 7.33 ± 3.81, respectively; p fluid responsiveness (area under the curve = 0.839, p = 0.0001). Pulse-pressure variation >7.69% identified the responders, with a sensitivity of 86% and a specificity of 83%. Pulse-pressure variation successfully predicted fluid responsiveness and would be useful in guiding fluid management during heart displacement for off-pump coronary artery bypass surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Calculation and analysis of velocity and viscous drag in an artery with a periodic pressure gradient

    Science.gov (United States)

    Alizadeh, M.; Seyedpour, S. M.; Mozafari, V.; Babazadeh, Shayan S.

    2012-07-01

    Blood as a fluid that human and other living creatures are dependent on has been always considered by scientists and researchers. Any changes in blood pressure and its normal velocity can be a sign of a disease. Whatever significant in blood fluid's mechanics is Constitutive equations and finding some relations for analysis and description of drag, velocity and periodic blood pressure in vessels. In this paper, by considering available experimental quantities, for blood pressure and velocity in periodic time of a thigh artery of a living dog, at first it is written into Fourier series, then by solving Navier-Stokes equations, a relation for curve drawing of vessel blood pressure with rigid wall is obtained. Likewise in another part of this paper, vessel wall is taken in to consideration that vessel wall is elastic and its pressure and velocity are written into complex Fourier series. In this case, by solving Navier-Stokes equations, some relations for blood velocity, viscous drag on vessel wall and blood pressure are obtained. In this study by noting that vessel diameter is almost is large (3.7 mm), and blood is considered as a Newtonian fluid. Finally, available experimental quantities of pressure with obtained curve of solving Navier-Stokes equations are compared. In blood analysis in rigid vessel, existence of 48% variance in pressure curve systole peak caused vessel blood flow analysis with elastic wall, results in new relations for blood flow description. The Resultant curve is obtained from new relations holding 10% variance in systole peak.

  13. Treatment of Ischial Pressure Sores with Both Profunda Femoris Artery Perforator Flaps and Muscle Flaps

    Science.gov (United States)

    Kim, Chae Min; Yun, In Sik; Lee, Dong Won; Lew, Dae Hyun; Rah, Dong Kyun

    2014-01-01

    Background Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. Methods We retrospectively analyzed data from 14 patients (16 ischial sores) whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. Results All flaps survived the entire follow-up period. Seven patients (50%) had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years). The mean follow-up period was 27.9 months (range, 3-57 months). In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%), wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%), but resolved with conservative treatment. Among 16 cases, there was only one (6%) recurrence at 34 months. Conclusions The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores. PMID:25075362

  14. Treatment of Ischial Pressure Sores with Both Profunda Femoris Artery Perforator Flaps and Muscle Flaps

    Directory of Open Access Journals (Sweden)

    Chae Min Kim

    2014-07-01

    Full Text Available Background Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. Methods We retrospectively analyzed data from 14 patients (16 ischial sores whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. Results All flaps survived the entire follow-up period. Seven patients (50% had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years. The mean follow-up period was 27.9 months (range, 3-57 months. In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%, wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%, but resolved with conservative treatment. Among 16 cases, there was only one (6% recurrence at 34 months. Conclusions The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores.

  15. Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial.

    Science.gov (United States)

    McGee, William T; Horswell, Jeffrey L; Calderon, Joachim; Janvier, Gerard; Van Severen, Tom; Van den Berghe, Greet; Kozikowski, Lori

    2007-01-01

    The present study compared measurements of cardiac output by an arterial pressure-based cardiac output (APCO) analysis method with measurement by intermittent thermodilution cardiac output (ICO) via pulmonary artery catheter in a clinical setting. The multicenter, prospective clinical investigation enrolled patients with a clinical indication for cardiac output monitoring requiring pulmonary artery and radial artery catheters at two hospitals in the United States, one hospital in France, and one hospital in Belgium. In 84 patients (69 surgical patients), the cardiac output was measured by analysis of the arterial pulse using APCO and was measured via pulmonary artery catheter by ICO; to establish a reference comparison, the cardiac output was measured by continuous cardiac output (CCO). Data were collected continuously by the APCO and CCO technologies, and at least every 4 hours by ICO. No clinical interventions were made as part of the study. For APCO compared with ICO, the bias was 0.20 l/min, the precision was +/- 1.28 l/min, and the limits of agreement were -2.36 l/m to 2.75 l/m. For CCO compared with ICO, the bias was 0.66 l/min, the precision was +/- 1.05 l/min, and the limits of agreement were -1.43 l/m to 2.76 l/m. The ability of APCO and CCO to assess changes in cardiac output was compared with that of ICO. In 96% of comparisons, APCO tracked the change in cardiac output in the same direction as ICO. The magnitude of change was comparable 59% of the time. For CCO, 95% of comparisons were in the same direction, with 58% of those changes being of similar magnitude. In critically ill patients in the intensive care unit, continuous measurement of cardiac output using either APCO or CCO is comparable with ICO. Further study in more homogeneous populations may refine specific situations where APCO reliability is strongest.

  16. Blood pressure response to low level static contractions

    DEFF Research Database (Denmark)

    Fallentin, Nils; Jørgensen, Kurt

    1992-01-01

    The present study re-examines the 15% MVC concept, i.e. the existence of a circulatory steady-state in low intensity static contractions below 15% of maximal voluntary contraction (MVC). Mean arterial blood pressure was studied during static endurance contractions of the elbow flexor and extensor...... 0.7) min for elbow extension]. Mean arterial blood pressure exhibited a continuous and progressive increase during the 10% MVC contractions indicating that the 15% MVC concept would not appear to be valid. The terminal blood pressure value recorded at the point of exhaustion in the 10% MVC elbow...... extension experiment was identical to the peak pressure attained in the 40% MVC contraction. For the elbow flexors the terminal pressor response was slightly but significantly lower at 10% MVC [122.3 (SD 10.1) mmHg, 16.3 (SD 1.4) kPa] in comparison with 40% MVC [130.4 (SD 7.4) mmHg, 17.4 (SD 1.0) kPa]. When...

  17. Influence of orlistat therapy on serum insulin level and morphological and functional parameters of peripheral arterial circulation in obese patients

    Directory of Open Access Journals (Sweden)

    Hajduković Zoran

    2005-01-01

    Full Text Available Background/Aim. Insulin resistance is related to accelerated atherosclerosis, whereas weight loss is associated with the increasing insulin sensitivity, the improvement of functional and the morphological parameters of arterial circulation, and the reduction of cardiovascular morbidity and mortality. The aim of our study was to evaluate the influence of orlistat treatment on serum insulin level and functional and morphologic parameters of peripheral arterial circulation. Methods. We conducted a prospective, randomized, double − blind, placebo − controlled study. Thirty patients with body mass index over 30 kg/m2 normotensive, nonsmokers, without clinically manifested cardiovascular disease or diabetes were randomly assigned either orlistat (120 mg, 3 times daily; n = 20 or placebo (n = 10 in a double − blind manner. All of the patients were on individually calculated hypocaloric diet. The follow-up period was 24 weeks. Arterial pressure, fasting serum glucose and insulin level, triglycerides, total cholesterol and low density lipoprotein-cholesterol were determined at the beginning, following 3 and 6 months. Also, the intima − media thickness of right superficial femoral artery and the mean blood flow velocity were determined with ultrasonography. Results. Inside the period of 3 and 6 months, there were the greater reductions of body mass index, arterial pressure, fasting glucose and insulin level, total cholesterol, low density lipoproteins, as well as the greater reductions of mean velocity blood flow and peripheral pulse pressure in the orlistat group vs the placebo group (p < 0.01. Greater reductions in the waist circumference and intima − media thickness were registered following 6 months in the orlistat vs the placebo group (p < 0.01. Conclusion. In the group of obese patients orlistat therapy reduced risk factors, serum insulin level and improved early arterial functional changes as assessed with the reductions of the mean

  18. Relationship Between Within-Visit Blood Pressure Variability and Kidney Function in Patients with Arterial Hypertension

    Directory of Open Access Journals (Sweden)

    Andrey Y. Kravchenko

    2017-06-01

    Full Text Available The main purpose of this study was to investigate the features of within-visit blood pressure variability (BPV in patients with arterial hypertension (AH and to assess the relationship of those features to impaired renal filtration. Material and Methods: The study included 120 patients with AH Stages I and II (ESH/ESC, 2013: 58(48.3% men and 62(51.7% women aged from 22 to 73 years (mean age 58.7±15 years. Average duration of AH was 15.0±6.7 years. BP was measured three times during visit. BP was measured three times at 2-minute intervals during one visit. Within-visit BPV was evaluated by the presence of an absolute difference (AD between any two readings of three SBP measurements of more than 5mmHg. All patients underwent a comprehensive examination, which included blood and urine tests, kidney ultrasound, assessment of blood levels of creatinine and TnT, and calculation of GFR. Results: Depending on the response of BP to repeated measurements, three types of BPV were identified. A prognostically unfavorable type of BPV, which is characterized by SBP-AD >5mmHg between the third and first measurements, was identified. Patients of this group had the lowest eGFR value that indicates more pronounced renal damage, and, as a consequence, worse prognosis. Also in these patients, there was an increase in TnT level, which is a predictor of the development of adverse cardiovascular complications.

  19. Isobolographic analysis of the interaction between fenoldopam and levodopa on arterial blood pressure of the rat.

    Science.gov (United States)

    Quevedo, M; Prieto, J C; Miranda, H F; Pinardi, G

    2000-09-01

    Fenoldopam (FD) and levodopa (LD) injected intravenously in rats in a noncumulative schedule induced dose-dependent reductions in mean arterial blood pressure. The doses that induced a 50% reduction in the initial control mean arterial pressure (referred as ED50) were calculated by linear regression analysis of the corresponding parallel dose-response curves and were 0.88 and 0.068 mg/kg, respectively. The interaction between the effects of FD and LD on pressure reduction was evaluated by simultaneous administration of different fixed ratios of FD and LD (16:1) and obtaining a dose-response curve. An isobolographic analysis was then performed, which showed that the experimental point for the effect of the simultaneous administration of FD and LD was significantly different from the theoretically calculated additive point, denoting supradditivity. It was concluded that the effect of the combination of FD and LD on mean blood pressure reduction was synergic and was probably due to an activation of D1 vascular receptors by both drugs, in conjunction with an activation of beta2 adrenoceptors by LD and a blocking action of FD on postsynaptic alpha1-adrenoceptors.

  20. Increased serum urea to creatinine ratio and its negative correlation with arterial pressure in canine babesiosis.

    Science.gov (United States)

    Zygner, Wojciech; Gójska-Zygner, Olga

    2014-09-01

    The increase of the serum urea to creatinine ratio (UCR) was observed in dogs infected with Babesia canis. Previous studies have suggested that decrease of blood pressure can be one of the reasons for this phenomenon. In this work statistically significant increase of the UCR was observed in dogs with babesiosis. Comparison of the UCR between 23 azotaemic dogs and 25 non-azotaemic dogs infected with Babesia canis showed statistically significantly higher mean of the UCR in azotaemic dogs. Correlations between UCR and systolic, diastolic and mean arterial pressure (SAP, DAP and MAP) in 48 dogs infected with B. canis were negative (UCR and SAP: r = -0.3909; UCR and DAP: r = -0.3182; UCR and MAP: r = -0.3682) and statistically significant (p babesiosis. However, the correlations were not high, and there was no statistically significant correlation between UCR and arterial pressures in azotaemic dogs. Thus, it seems that decrease of blood pressure in dogs with babesiosis explains only partially the cause of increased UCR in infected dogs. The other authors suggested hyperureagenesis and myocardial injury as a potential reason for the increased UCR in canine babesiosis. Thus, further studies are needed to determine causes of increased UCR in dogs with babesiosis, especially on the connection between UCR changes and the concentrations of plasma cardiac troponins and ammonia, and the occurrence of occult blood on fecal examination.

  1. Influence of physical exercise and sodium intake on arterial pressure and cardiac hypertrophy in rats

    Directory of Open Access Journals (Sweden)

    Santos Bruno Mello Rodrigues dos

    1999-01-01

    Full Text Available Evidence shows that cardiac hypertrophy (CH is a risk factor for many cardiovascular diseases. Several stimuli may cause CH-like manifestations and promote volume or pressure overload. Exercise-induced cardiac hypertrophy is an expected adaptation to regular exercise training. Salt intake has been shown to be the most important determinant of blood pressure in different populations. The purpose of the present work was to verify the influence of physical exercise and sodium intake on the blood pressure and myocardium. The study was performed on 36 rats divided into six groups: Group I (diet without salt overload, Group II (diet without salt overload and swimming, Group III (diet with 2.5% NaCl solution and swimming, Group IV (diet with 5% NaCl solution and swimming, Group V (diet with 2.5% NaCl solution without exercise, Group VI (diet with 5% NaCl solution without exercise. The arterial pressure was significantly lower in Group I when compared with Group IV. The ratio of cardiac mass/body mass was increased in Groups III and IV. In conclusion, there was evidence that exercise training and NaCl intake promotes arterial hypertension and cardiac hypertrophy.

  2. The interplay of exercise heart rate and blood pressure as a predictor of coronary artery disease and arterial hypertension.

    Science.gov (United States)

    Michaelides, Andreas P; Liakos, Charalampos I; Vyssoulis, Gregory P; Chatzistamatiou, Evangelos I; Markou, Maria I; Tzamou, Vanessa; Stefanadis, Christodoulos I

    2013-03-01

    Delayed blood pressure (BP) and heart rate (HR) decline at recovery post-exercise are independent predictors of incident coronary artery disease (CAD). Delayed BP recovery and exaggerated BP response to exercise are independent predictors of future arterial hypertension (AH). This study sought to examine whether the combination of two exercise parameters provides additional prognostic value than each variable alone. A total of 830 non-CAD patients (374 normotensive) were followed for new-onset CAD and/or AH for 5 years after diagnostic exercise testing (ET). At the end of follow-up, patients without overt CAD underwent a second ET. Stress imaging modalities and coronary angiography, where appropriate, ruled out CAD. New-onset CAD was detected in 110 participants (13.3%) whereas AH was detected in 41 former normotensives (11.0%). The adjusted (for confounders) relative risk (RR) of CAD in abnormal BP and HR recovery patients was 1.95 (95% confidence interval [CI], 1.28-2.98; P=.011) compared with delayed BP and normal HR recovery patients and 1.71 (95% CI, 1.08-2.75; P=.014) compared with normal BP and delayed HR recovery patients. The adjusted RR of AH in normotensives with abnormal BP recovery and response was 2.18 (95% CI, 1.03-4.72; P=.047) compared with delayed BP recovery and normal BP response patients and 2.48 (95% CI, 1.14-4.97; P=.038) compared with normal BP recovery and exaggerated BP response individuals. In conclusion, the combination of two independent exercise predictors is an even stronger CAD/AH predictor than its components. © 2012 Wiley Periodicals, Inc.

  3. PREDICTION OF BLOOD PATTERN IN S-SHAPED MODEL OF ARTERY UNDER NORMAL BLOOD PRESSURE

    Directory of Open Access Journals (Sweden)

    Mohd Azrul Hisham Mohd Adib

    2013-06-01

    Full Text Available Athletes are susceptible to a wide variety of traumatic and non-traumatic vascular injuries to the lower limb. This paper aims to predict the three-dimensional flow pattern of blood through an S-shaped geometrical artery model. This model has created by using Fluid Structure Interaction (FSI software. The modeling of the geometrical S-shaped artery is suitable for understanding the pattern of blood flow under constant normal blood pressure. In this study, a numerical method is used that works on the assumption that the blood is incompressible and Newtonian; thus, a laminar type of flow can be considered. The authors have compared the results with a previous study with FSI validation simulation. The validation and verification of the simulation studies is performed by comparing the maximum velocity at t = 0.4 s, because at this time, the blood accelerates rapidly. In addition, the resulting blood flow at various times, under the same boundary conditions in the S-shaped geometrical artery model, is presented. The graph shows that velocity increases linearly with time. Thus, it can be concluded that the flow of blood increases with respect to the pressure inside the body.

  4. [Gluteal artery based perforator flaps for sacral pressure sore reconstruction in children].

    Science.gov (United States)

    Berenguer, B; Simal, I; Marín, M C; E de Tomás; Riquelme, O; García Martín, A; González, J L

    2014-10-01

    Children have much lower incidence of pressure sores (PS) than adults and furthermore, they are diagnosed in earlier stages. Therefore, the reported experience with surgical treatment of advanced pediatric PS is scarce. We present the surgical treatment of 2 chronic PS stage IV in children aged 11 and 14 years, by means of perforator flaps based on the gluteal arteries: in the first case we used a free-style flap based on a left medial gluteal perforator and in the second a large reusable rotation-advancement flap based on both right superior and inferior gluteal artery perforators. In both patients we achieved a rapid cure with 100% survival of the flaps and a stable cover over a 6 month and 1 year follow-up respectively. Gluteal artery perforator flaps can produce excellent and durable results in the reconstructive treatment of sacral pressure sores in children. These flaps carry lower morbidity than musculocutaneous flaps and are more reliable than traditional fasciocutaneous flaps. Furthermore they preserve more reconstructive options in case of recurrence during the children's lifetime.

  5. Effect of oral garlic on arterial oxygen pressure in children with hepatopulmonary syndrome

    Institute of Scientific and Technical Information of China (English)

    Mehri Najafi Sani; Hamid Reza Kianifar; Abdolrazagh Kianee; Gholamreza Khatami

    2006-01-01

    AIM: To study the effect of oral garlic on arterial oxygen pressure in children with hepatopulmonary syndrome.METHODS: Garlic powder in a capsule form was given to 15 children with hepatopulmonary syndrome (confirmed by contrast echocardiography) at the dosage of 1g/1.73 m2 per day. Patients were evaluated clinically and by arterial blood gas every four weeks.RESULTS: The garlic capsule was administered to 15patients with hepatopulmonary syndrome. There were 10 boys and 5 girls with a mean age of 9.4±3.9 years.The underlying problems were biliary tract atresia (4patients), autoimmune hepatitis (4 patients), cryptogenic cirrhosis (4 patients) and presinusoidal portal hypertension (3 patients). Eight patients (53.3%) showed an increase of 10 mmHg in their mean arterial oxygen pressure. The baseline PaO2 was 65.6±12.1 mmHg in the responder group and 47.1±11.2 mmHg in nonresponder group. At the end of treatment the mean PaO2 in responders and non-responders was 92.2±7.75mmHg and 47.5±11.87 mmHg, respectively (P<0.01).CONCLUSION: Garlic may increase oxygenation and improve dyspnea in children with hepatopulmonary syndrome.

  6. Anomalous pressure dependence of the torsional levels in solid nitromethane

    Science.gov (United States)

    Cavagnat, D.; Magerl, A.; Vettier, C.; Anderson, I. S.; Trevino, S. F.

    1985-01-01

    Inelastic neutron-scattering measurement of the torsional levels of CH3NO2 and CD3NO2 are presented as functions of pressure and temperature. In contrast to all previously observed pressure dependence of hindered rotors, the ground-state tunnel splitting increases and the energies of the bound torsional levels decrease with pressure. A potential which reproduces these anomalous effects is found and the source of the anomaly explained.

  7. Increased wall tension in response to vasoconstrictors in isolated mesenteric arterial rings from patients with high blood pressure.

    Science.gov (United States)

    Tahvanainen, Anna; Taurio, Jyrki; Mäki-Jouppi, Jenni; Kööbi, Peeter; Mustonen, Jukka; Kähönen, Mika; Sand, Juhani; Nordback, Isto; Pörsti, Ilkka

    2006-12-01

    Essential hypertension is associated with several alterations in arterial function. A wealth of information from animal models is available concerning hypertensive changes in the mesenteric circulation, while only few studies have examined human mesenteric arterial function. The tone of isolated mesenteric arterial segments (outer diameter 0.7-0.9 mm) was examined from individuals with high (n=17) or normal (n=22) blood pressure, grouped using the current definition of elevated blood pressure (140/90 mmHg). Since the majority of them were operated because of malignancies, we evaluated whether functional vascular properties provided information about patient prognosis. Wall tension development (mN/mm) in response to vasoconstrictors (noradrenaline, 5-hydroxy tryptamine, potassium chloride) was higher in mesenteric arterial rings from patients with high than normal blood pressure. There was no difference in vasoconstrictor sensitivity, or endothelium-dependent and endothelium-independent vasorelaxation. Arterial segment weight was higher in hypertensive subjects, suggesting vascular wall hypertrophy. The 10-year follow-up showed no differences in the control of arterial tone between the surviving (n=14) or deceased (n=25) patients. In conclusion, isolated mesenteric arterial segments from hypertensive patients showed increased wall tension in response to vasoconstrictors. Since the mesenteric circulation is an important regulator of peripheral arterial resistance, possible functional alterations in this vascular bed should be further investigated in hypertensive patients.

  8. Evaluation of continuous non-invasive arterial pressure monitoring during induction of general anaesthesia in patients undergoing cardiac surgery.

    Science.gov (United States)

    Kumar, G Anil; Jagadeesh, A M; Singh, Naveen G; Prasad, S R

    2015-01-01

    Continuous arterial pressure monitoring is essential in cardiac surgical patients during induction of general anaesthesia (GA). Continuous non-invasive arterial pressure (CNAP) monitoring is fast gaining importance due to complications associated with the invasive arterial monitoring. Recently, a new continuous non-invasive arterial pressure device (CNAP™) has been validated perioperatively in non-cardiac surgeries. The aim of our study is to compare and assess the performance of CNAP during GA with invasive arterial pressure (IAP) in patients undergoing cardiac surgeries. Sixty patients undergoing cardiac surgery were included. Systolic, diastolic, and mean arterial pressure (MAP) data were recorded every minute for 20 min simultaneously for both IAP and CNAP™. Statistical analysis was performed using mountain plot and Bland Altman plots for assessing limits of agreement and bias (accuracy) calculation. Totally 1200 pairs of data were analysed. The CNAP™ systolic, diastolic and MAP bias was 5.98 mm Hg, -3.72 mm Hg, and - 0.02 mm Hg respectively. Percentage within limits of agreement was 96.0%, 95.2% and 95.7% for systolic, diastolic and MAP. The mountain plot showed similar results as the Bland Altman plots. We conclude CNAP™ provides real-time estimates of arterial pressure comparable to IAP during induction of GA for cardiac surgery. We recommend CNAP can be used as an alternative to IAP in situations such as cardiac patients coming for non-cardiac surgeries, cardiac catheterization procedures, positive Allen's test, inability to cannulate radial artery and vascular diseases, where continuous blood pressure monitoring is required.

  9. Effects of 8 hemodynamic conditions on direct blood pressure values obtained simultaneously from the carotid, femoral and dorsal pedal arteries in dogs.

    Science.gov (United States)

    Monteiro, Eduardo R; Campagnol, Daniela; Bajotto, Gustavo C; Simões, Clarissa R; Rassele, Alice C

    2013-12-01

    This study aimed to evaluate the effect of 8 hemodynamic conditions on blood pressure measurements taken from the carotid, femoral and dorsal pedal arteries of dogs. Six healthy dogs. During isoflurane anesthesia, catheters were introduced into the carotid, femoral and dorsal pedal arteries of dogs to allow simultaneous monitoring of direct blood pressure in each artery. The dogs were submitted to 8 hemodynamic conditions induced by combining changes in heart rate (bradycardia, normocardia, tachycardia) with changes in blood pressure (hypotension, normotension, hypertension). Values obtained from each arterial catheter were compared and agreement between central (carotid) and peripheral (femoral and dorsal pedal) values were analyzed by the Bland-Altman method. During hypotensive conditions, systolic arterial pressure (SAP) was lower in the femoral and dorsal pedal arteries compared to the carotid artery whereas during normotensive and hypertensive conditions, SAP was higher in peripheral arteries. During hypotensive states, increases in heart rate resulted in greater bias between central and peripheral SAP whereas during normotensive states, the bias decreased as heart rate increased. Mean and diastolic arterial pressures were lower in the femoral and dorsal pedal arteries than in the carotid artery during most hemodynamic conditions. In healthy anesthetized dogs, invasive blood pressure measurements in peripheral arteries may differ significantly from measurements in a central artery. The greatest differences were observed in SAP and the magnitude of differences between central and peripheral blood pressure measurements varied according to the dog's hemodynamic condition. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Selective Heart Rate Reduction With Ivabradine Increases Central Blood Pressure in Stable Coronary Artery Disease.

    Science.gov (United States)

    Rimoldi, Stefano F; Messerli, Franz H; Cerny, David; Gloekler, Steffen; Traupe, Tobias; Laurent, Stéphane; Seiler, Christian

    2016-06-01

    Heart rate (HR) lowering by β-blockade was shown to be beneficial after myocardial infarction. In contrast, HR lowering with ivabradine was found to confer no benefits in 2 prospective randomized trials in patients with coronary artery disease. We hypothesized that this inefficacy could be in part related to ivabradine's effect on central (aortic) pressure. Our study included 46 patients with chronic stable coronary artery disease who were randomly allocated to placebo (n=23) or ivabradine (n=23) in a single-blinded fashion for 6 months. Concomitant baseline medication was continued unchanged throughout the study except for β-blockers, which were stopped during the study period. Central blood pressure and stroke volume were measured directly by left heart catheterization at baseline and after 6 months. For the determination of resting HR at baseline and at follow-up, 24-hour ECG monitoring was performed. Patients on ivabradine showed an increase of 11 mm Hg in central systolic pressure from 129±22 mm Hg to 140±26 mm Hg (P=0.02) and in stroke volume by 86±21.8 to 107.2±30.0 mL (P=0.002). In the placebo group, central systolic pressure and stroke volume remained unchanged. Estimates of myocardial oxygen consumption (HR×systolic pressure and time-tension index) remained unchanged with ivabradine.The decrease in HR from baseline to follow-up correlated with the concomitant increase in central systolic pressure (r=-0.41, P=0.009) and in stroke volume (r=-0.61, PHeart Association, Inc.

  11. Giant, dissecting, high-pressure pulmonary artery aneurysm: case report of a 1-year natural course.

    Science.gov (United States)

    Smalcelj, Anton; Brida, Vojtjeh; Samarzija, Miroslav; Matana, Ante; Margetic, Eduard; Drinkovic, Niksa

    2005-01-01

    We report the rare subchronic clinical course of a giant, dissecting pulmonary artery aneurysm in an oligosymptomatic middle-aged woman who had idiopathic pulmonary hypertension. Diagnosis was simple with the use of echocardiography and multislice computed tomography. Conversely, deciding on the treatment was difficult, because prominent surgeons declined to perform surgical repair of the aneurysm and recommended heart-lung transplantation. Therefore, we were forced to treat our patient medically. She survived for 1 year, including 8 months of treatment with sildenafil, and then died suddenly while awaiting transplantation. Our patient, who had a dissecting, high-pressure pulmonary artery aneurysm, had an unexpectedly stable and uneventful clinical course for 1 year, which, under more favorable circumstances, might have provided enough time for heart-lung transplantation to be performed.

  12. Longitudinal perspective on the conundrum of central arterial stiffness, blood pressure, and aging.

    Science.gov (United States)

    Scuteri, Angelo; Morrell, Christopher H; Orrù, Marco; Strait, James B; Tarasov, Kirill V; Ferreli, Liana Anna Pina; Loi, Francesco; Pilia, Maria Grazia; Delitala, Alessandro; Spurgeon, Harold; Najjar, Samer S; AlGhatrif, Majd; Lakatta, Edward G

    2014-12-01

    The age-associated increase in arterial stiffness has long been considered to parallel or to cause the age-associated increase in blood pressure (BP). Yet, the rates at which pulse wave velocity (PWV), a measure of arterial stiffness, and BP trajectories change over time within individuals who differ by age and sex have not been assessed and compared. This study determined the evolution of BP and aortic PWV trajectories during a 9.4-year follow-up in >4000 community-dwelling men and women of 20 to 100 years of age at entry into the SardiNIA Study. Linear mixed effects model analyses revealed that PWV accelerates with time during the observation period, at about the same rate over the entire age range in both men and women. In men, the longitudinal rate at which BP changed over time, however, did not generally parallel that of PWV acceleration: at ages>40 years the rates of change in systolic BP (SBP) and pulse pressure (PP) increase plateaued and then declined so that SBP, itself, also declined at older ages, whereas PP plateaued. In women, SBP, diastolic BP, and mean BP increased at constant rates across all ages, producing an increasing rate of increase in PP. Therefore, increased aortic stiffness is implicated in the age-associated increase in SBP and PP. These findings indicate that PWV is not a surrogate for BP and that arterial properties other than arterial wall stiffness that vary by age and sex also modulate the BP trajectories during aging and lead to the dissociation of PWV, PP, and SBP trajectories in men.

  13. Relationship between pulmonary arterial pressure and pulmonary thromboembolism associated with dead worms in canine heartworm disease.

    Science.gov (United States)

    Hirano, Y; Kitagawa, H; Sasaki, Y

    1992-10-01

    To examine effects of thromboemboli due to dead worms on pulmonary arterial pressure (PAP), 20 to 50 dead heartworms were inserted into the pulmonary arteries of 4 heartworm uninfected dogs (uninfected group) and 11 dogs infected with heartworms (infected group). In the uninfected group, the mean PAP rose 1 week after worm insertion (10.9 to 166. mmHg), but it recovered by the 4th week. Clinical signs, hemodynamics and blood gas findings also deteriorated at the 1st week, but recovered at the 4th week. Angiographic and pathological findings indicated that blood flow recovered through the spaces between thromboemboli and vessel walls at the 4th week. The infected dogs were divided into three groups. In the infected-I group (5 dogs), the intimal lesions of the pulmonary arteries were slight, and clinical and laboratory findings showed changes similar to those of the uninfected group. In the infected-II group (4 dogs), the pulmonary arterial lesions were severe and the mean PAP was higher (25.7 mmHg) than in the uninfected group before worm insertion. An increase in PAP (34.1 mmHg) and worsening of clinical and laboratory findings were noticed till the 4th week. Thromboemboli adhered extensively to the vessel walls. Two dogs in the infected-III group died of severe dyspnea on the 9th and 10th day, and the mean PAP rose remarkably at the 1st week (from 19.4 to 28.2 mmHg). Severe pulmonary parenchymal lesions with edema or perforation were observed. From the above results, it was clarified that effects of dead worms on PAP and clinical signs depended on the severity of pulmonary arterial lesions before worm insertion.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Elevated pulmonary artery pressure and brain natriuretic peptide in high altitude pulmonary edema susceptible non-mountaineers

    Science.gov (United States)

    Gupta, Rajinder K.; Himashree, G.; Singh, Krishan; Soree, Poonam; Desiraju, Koundinya; Agrawal, Anurag; Ghosh, Dishari; Dass, Deepak; Reddy, Prassana K.; Panjwani, Usha; Singh, Shashi Bala

    2016-01-01

    Exaggerated pulmonary pressor response to hypoxia is a pathgonomic feature observed in high altitude pulmonary edema (HAPE) susceptible mountaineers. It was investigated whether measurement of basal pulmonary artery pressure (Ppa) and brain natriuretic peptide (BNP) could improve identification of HAPE susceptible subjects in a non-mountaineer population. We studied BNP levels, baseline hemodynamics and the response to hypoxia (FIo2 = 0.12 for 30 min duration at sea level) in 11 HAPE resistant (no past history of HAPE, Control) and 11 HAPE susceptible (past history of HAPE, HAPE-S) subjects. Baseline Ppa (19.31 ± 3.63 vs 15.68 ± 2.79 mm Hg, p < 0.05) and plasma BNP levels (52.39 ± 32.9 vs 15.05 ± 9.6 pg/ml, p < 0.05) were high and stroke volume was less (p < 0.05) in HAPE-S subjects compared to control. Acute hypoxia produced an exaggerated increase in heart rate (p < 0.05), mean arterial pressure (p < 0.05) and Ppa (28.2 ± 5.8 vs 19.33 ± 3.74 mm Hg, p < 0.05) and fall in peripheral oxygen saturation (p < 0.05) in HAPE-S compared to control. Receiver operating characteristic (ROC) curves showed that Ppa response to acute hypoxia was the best variable to identify HAPE susceptibility (AUC 0.92) but BNP levels provided comparable information (AUC 0.85). BNP levels are easy to determine and may represent an important marker for the determination of HAPE susceptibility. PMID:26892302

  15. An innovative method to measure the peripheral arterial elasticity: spring constant modeling based on the arterial pressure wave with radial vibration.

    Science.gov (United States)

    Wei, Ching-Chuan

    2011-11-01

    In this study, we propose an innovative method for the direct measurement of the peripheral artery elasticity using a spring constant model, based on the arterial pressure wave equation, vibrating in a radial direction. By means of the boundary condition of the pressure wave equation at the maximum peak, we can derive the spring constant used for evaluating peripheral arterial elasticity. The calculated spring constants of six typical subjects show a coincidence with their proper arterial elasticities. Furthermore, the comparison between the spring constant method and pulse wave velocity (PWV) was investigated in 70 subjects (21-64 years, 47 normotensives and 23 hypertensives). The results reveal a significant negative correlation for the spring constant vs. PWV (correlation coefficient = -0.663, p constant method to assess the arterial elasticity is carefully verified, and it is shown to be effective as well as fast. This method should be useful for healthcare, not only in improving clinical diagnosis of arterial stiffness but also in screening subjects for early evidence of cardio-vascular diseases and in monitoring responses to therapy in the future.

  16. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Directory of Open Access Journals (Sweden)

    Amann Matthias

    2007-11-01

    Full Text Available Abstract Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC measurement by the pulmonary artery catheter (PAC. However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years, who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min. The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC and percentage changes in COAP (ΔCOAP for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p PAC and ΔCOAP was 0.46 (p Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03 failed to

  17. Monounsaturated fatty acid, carbohydrate intake, and diabetes status are associated with arterial pulse pressure

    Directory of Open Access Journals (Sweden)

    Vaccaro Joan A

    2011-11-01

    Full Text Available Abstract Background Diabetes is a global epidemic. Cardiovascular disease (CVD is one of the most prevalent consequences of diabetes. Nutrition is considered a modifiable risk factor for CVD, particularly for individuals with diabetes; albeit, there is little consensus on the role of carbohydrates, proteins and fats for arterial health for persons with or without diabetes. In this study, we examined the association of macronutrients with arterial pulse pressure (APP, a surrogate measure of arterial health by diabetes status and race. Methods Participants were 892 Mexican Americans (MA, 1059 Black, non-Hispanics (BNH and 2473 White, non-Hispanics (WNH with and without diabetes of a weighted sample from the National Nutrition and Health Examination Survey (NHANES 2007-2008. The cross-sectional analysis was performed with IBM-SPSS version 18 with the complex sample analysis module. The two-year sample weight for the sub-sample with laboratory values was applied to reduce bias and approximate a nationally, representative sample. Arterial stiffness was assessed by arterial pulse pressure (APP. Results APP was higher for MA [B = 0.063 (95% CI 0.015 to 0.111, p = 0.013] and BNH [B = 0.044 (95% CI 0.006 to 0.082, p = 0.018] than WNH, controlling for diabetes, age, gender, body mass index (BMI, fiber intake, energy intake (Kcal and smoking. A two-way interaction of diabetes by carbohydrate intake (grams was inversely associated with APP [B = -1.18 (95% CI -0.178 to -0.058, p = 0.001], controlling for race, age, gender, BMI, Kcal and smoking. BNH with diabetes who consumed more mono-unsaturated fatty acids (MUFA than WNH with diabetes had lower APP [B = -0.112 (95%CI-0.179 to -0.045, p = 0.003] adjusting for saturated fatty acids, Kcal, age, gender, BMI and smoking. Conclusion Higher MUFA and carbohydrate intake for persons with diabetes reflecting lower APP may be due to replacement of saturated fats with CHO and MUFA. The associations of APP with

  18. Nicorandil prevents right ventricular remodeling by inhibiting apoptosis and lowering pressure overload in rats with pulmonary arterial hypertension.

    Directory of Open Access Journals (Sweden)

    Xiang-Rong Zuo

    Full Text Available BACKGROUND: Most of the deaths among patients with severe pulmonary arterial hypertension (PAH are caused by progressive right ventricular (RV pathological remodeling, dysfunction, and failure. Nicorandil can inhibit the development of PAH by reducing pulmonary artery pressure and RV hypertrophy. However, whether nicorandil can inhibit apoptosis in RV cardiomyocytes and prevent RV remodeling has been unclear. METHODOLOGY/PRINCIPAL FINDINGS: RV remodeling was induced in rats by intraperitoneal injection of monocrotaline (MCT. RV systolic pressure (RVSP was measured at the end of each week after MCT injection. Blood samples were drawn for brain natriuretic peptide (BNP ELISA analysis. The hearts were excised for histopathological, ultrastructural, immunohistochemical, and Western blotting analyses. The MCT-injected rats exhibited greater mortality and less weight gain and showed significantly increased RVSP and RV hypertrophy during the second week. These worsened during the third week. MCT injection for three weeks caused pathological RV remodeling, characterized by hypertrophy, fibrosis, dysfunction, and RV mitochondrial impairment, as indicated by increased levels of apoptosis. Nicorandil improved survival, weight gain, and RV function, ameliorated RV pressure overload, and prevented maladaptive RV remodeling in PAH rats. Nicorandil also reduced the number of apoptotic cardiomyocytes, with a concomitant increase in Bcl-2/Bax ratio. 5-hydroxydecanoate (5-HD reversed these beneficial effects of nicorandil in MCT-injected rats. CONCLUSIONS/SIGNIFICANCE: Nicorandil inhibits PAH-induced RV remodeling in rats not only by reducing RV pressure overload but also by inhibiting apoptosis in cardiomyocytes through the activation of mitochondrial ATP-sensitive K(+ (mitoK(ATP channels. The use of a mitoK(ATP channel opener such as nicorandil for PAH-associated RV remodeling and dysfunction may represent a new therapeutic strategy for the amelioration of RV

  19. [Pulmonary artery wedge pressure and heart rate measurement during pharmacological stress induction for left cardial function diagnosis in horses with and without heart disease].

    Science.gov (United States)

    Gehlen, H; Groner, U; Rohn, K; Stadler, P

    2006-07-01

    In 18 horses, the pulmonary artery wedge pressure and the heart rate were measured during pharmacological stress load. 12 horses were healthy (4 trained, 8 untrained) and 6 horses had a heart disease (3 trained, 3 untrained). Pharmacological stress induction was carried out with the sympathomimetic drug dobutamine at a dosage rate of 7.5 microg/kg/min over 10 minutes of infusion. At the fourth minute, the parasympatholytic drug atropine was administered (5 microg/kg bw), and the heart rate and the pulmonary artery wedge pressure were continuously measured over 26 minutes. During sole dobutamine infusion, a significant decrease in heart rate and a significant increase in pulmonary artery wedge pressure were observed. After the application of atropine in the fourth minute, a significant increase in heart rate (from 35.7 +/- 6 up to 106 +/- 38/ min) and in pulmonary artery wedge pressure (from 15.7 +/- 3 up to 24 +/- 8.6 mmHg) were visible in the group of healthy horses. The horses with heart diseases had a significantly higher increase in both parameters (heart rate and pulmonary artery wedge pressure) with a significantly positive correlation (r = 0.7). The heart rate increased in the horses with heart diseases from 35.2 +/- 2,8 beats/min up to 132 +/- 45.7 beats/min and the pulmonary artery wedge pressure increased from 17.3 +/- 3,2 mmHg up to 32.7 +/- 13 mmHg. The cardiac status (healthy or heart disease) as well as the training level of the horses (untrained or trained) had a significant influence on the heart rate and the pulmonary artery wedge pressure. The untrained horses (healthy and heart disease) showed significantly higher values over a longer period of time than did the trained horses with the same cardiac status. Additionally the influence of pharmacological stress induction on echocardiographic parameters was investigated. The left atrial size (p = 0.015) and left ventricular diameter were significanly different in the systole (p = 0.008) and in the

  20. Vitamin D induces increased systolic arterial pressure via vascular reactivity and mechanical properties.

    Directory of Open Access Journals (Sweden)

    Priscila Portugal Dos Santos

    Full Text Available The aim of this study was to evaluate whether supplementation of high doses of cholecalciferol for two months in normotensive rats results in increased systolic arterial pressure and which are the mechanisms involved. Specifically, this study assesses the potential effect on cardiac output as well as the changes in aortic structure and functional properties.Male Wistar rats were divided into three groups: 1 Control group (C, n = 20, with no supplementation of vitamin D, 2 VD3 (n = 19, supplemented with 3,000 IU vitamin D/kg of chow; 3 VD10 (n = 21, supplemented with 10,000 IU vitamin D/kg of chow. After two months, echocardiographic analyses, measurements of systolic arterial pressure (SAP, vascular reactivity, reactive oxygen species (ROS generation, mechanical properties, histological analysis and metalloproteinase-2 and -9 activity were performed.SAP was higher in VD3 and VD10 than in C rats (p = 0.001. Echocardiographic variables were not different among groups. Responses to phenylephrine in endothelium-denuded aortas was higher in VD3 compared to the C group (p = 0.041. Vascular relaxation induced by acetylcholine (p = 0.023 and sodium nitroprusside (p = 0.005 was impaired in both supplemented groups compared to the C group and apocynin treatment reversed impaired vasodilation. Collagen volume fraction (<0.001 and MMP-2 activity (p = 0.025 was higher in VD10 group compared to the VD3 group. Elastin volume fraction was lower in VD10 than in C and yield point was lower in VD3 than in C.Our findings support the view that vitamin D supplementation increases arterial pressure in normotensive rats and this is associated with structural and functional vascular changes, modulated by NADPH oxidase, nitric oxide, and extracellular matrix components.

  1. Relations between a novel, reliable, and rapid index of arterial compliance (PP-HDI) and well-established inidices of arterial blood pressure (ABP) in a sample of hypertensive elderly subjects.

    Science.gov (United States)

    Bergamini, L; Finelli, M E; Bendini, C; Ferrari, E; Veschi, M; Neviani, F; Manni, B; Pelosi, A; Rioli, G; Neri, M

    2009-01-01

    Hypertension is a risk factor for a long-lasting arterial wall-remodelling leading to stiffness. The rapid method measuring the pulse pressure (PP) by means of the tool of Hypertension Diagnostic Instruments (HDI) called PP-HDI, overcomes some of the problems arising with more-time consuming methods, like ambulatory blood pressure monitoring (ABPM), and give information about the elasticity of the arterial walls. We studied the relationship between the PP-HDI, the large artery compliance (LA-C) and small artery compliance (SA-C) and few well-established indices of arterial blood pressure (ABP) in a sample of 75 hypertensive subjects, aged 65 years and over. Significant correlations between LA-C and heart rate (HR), PP-ABPM and PP-HDI were found. SA-C relates with HR and systolic blood pressure (SBP) measured in lying and standing positions. Applying a stepwise regression analysis, we found that LA-C variance stems from PP-HDI and HR, while SA-C variance stems from SBP in lying position. Receiver operator characteristic (ROC) curves for thresholds of PP showed that PP-HDI reached levels of sensitivity/specificity similar to PP-ABPM. In conclusion, surveillance of ABP through hemo-dynamic indices, in particular of SBP, is essential, nevertheless the advantage of this control is not known in an elderly population where the organ damage is already evident. PP needs necessarily an instrumental measurement. The PP-HDI result is similar in reliability with respect to PPABPM, but is more rapid and well applicable in an elderly population.

  2. Ventricular mass index correlates with pulmonary artery pressure and predicts survival in suspected systemic sclerosis-associated pulmonary arterial hypertension.

    Science.gov (United States)

    Hagger, Dan; Condliffe, Robin; Woodhouse, Neil; Elliot, Charlie A; Armstrong, Iain J; Davies, Christine; Hill, Catherine; Akil, Mohammed; Wild, Jim M; Kiely, David G

    2009-09-01

    The ventricular mass index (VMI) has been proposed as a diagnostic tool for the assessment of patients with suspected pulmonary hypertension (PH). We hypothesized that in patients with SSc it may predict the presence or absence of PH. Details of all consecutive SSc patients undergoing MRI and right heart catheterization were collected prospectively. Subsequently, the VMI for all patients was calculated, and further baseline data were collected. Data for 40 patients, 28 of whom were diagnosed with PH at rest (PH(REST)), were analysed. VMI correlated strongly with mean pulmonary artery pressure (mPAP; r = 0.79). Using a VMI threshold of 0.56, positive predictive value (PPV) for PH(REST) was 88% and negative predictive value (NPV) was 100%. Using a threshold of 0.7, PPV was found to be 100% and NPV 53%. Echocardiographically obtained tricuspid gradient (TG) also demonstrated a strong correlation with mPAP. Two-year survival in patients with VMI or =0.7 was 91 and 43%, respectively (P VMI correlates well with mPAP in patients with SSc and may have a role in non-invasively excluding clinically significant PH in breathless SSc patients in whom echocardiographic screening has failed. Further study in larger groups of patients is justified.

  3. Acute-Phase Blood Pressure Levels Correlate With a High Risk of Recurrent Strokes in Young-Onset Ischemic Stroke.

    Science.gov (United States)

    Mustanoja, Satu; Putaala, Jukka; Gordin, Daniel; Tulkki, Lauri; Aarnio, Karoliina; Pirinen, Jani; Surakka, Ida; Sinisalo, Juha; Lehto, Mika; Tatlisumak, Turgut

    2016-06-01

    High blood pressure (BP) in acute stroke has been associated with a poor outcome; however, this has not been evaluated in young adults. The relationship between BP and long-term outcome was assessed in 1004 consecutive young, first-ever ischemic stroke patients aged 15 to 49 years enrolled in the Helsinki Young Stroke Registry. BP parameters included systolic (SBP) and diastolic BP, pulse pressure, and mean arterial pressure at admission and 24 hours. The primary outcome measure was recurrent stroke in the long-term follow-up. Adjusted for demographics and preexisting comorbidities, Cox regression models were used to assess independent BP parameters associated with outcome. Of our patients (63% male), 393 patients (39%) had prestroke hypertension and 358 (36%) used antihypertensive treatment. The median follow-up period was 8.9 years (interquartile range 5.7-13.2). Patients with a recurrent stroke (n=142, 14%) had significantly higher admission SBP, diastolic BP, pulse pressure, and mean arterial pressure (Ppressure compared with patients without the recurrent stroke. Patients with SBP ≥160 mm Hg compared with those with SBP pressure, and mean arterial pressure were independently associated with the risk of recurrent stroke, while the 24-hour BP levels were not. In young ischemic stroke patients, high acute phase BP levels are independently associated with a high risk of recurrent strokes. © 2016 American Heart Association, Inc.

  4. Comparison of continuous non-invasive finger arterial pressure monitoring with conventional intermittent automated arm arterial pressure measurement in patients under general anaesthesia.

    Science.gov (United States)

    Vos, J J; Poterman, M; Mooyaart, E A Q; Weening, M; Struys, M M R F; Scheeren, T W L; Kalmar, A F

    2014-07-01

    For a majority of patients undergoing anaesthesia for general surgery, mean arterial pressure (MAP) is only measured intermittently by arm cuff oscillometry (MAPiNIAP). In contrast, the Nexfin(®) device provides continuous non-invasive measurement of MAP (MAPcNIAP) using a finger cuff. We explored the agreement of MAPcNIAP and MAPiNIAP with the gold standard: continuous invasive MAP measurement by placement of a radial artery catheter (MAPinvasive). In a total of 120 patients undergoing elective general surgery and clinically requiring MAPinvasive measurement, MAPiNIAP and MAPcNIAP were measured in a 30 min time period at an arbitrary moment during surgery with stable haemodynamics. MAPiNIAP was measured every 5 min. Data from 112 patients were analysed. Compared with MAPinvasive, modified Bland-Altman analysis revealed a bias (sd) of 2 (9) mm Hg for MAPcNIAP and -2 (12) mm Hg for MAPiNIAP. Percentage errors for MAPcNIAP and MAPiNIAP were 22% and 32%, respectively. In a haemodynamically stable phase in patients undergoing general anaesthesia, the agreement with invasive MAP of continuous non-invasive measurement using a finger cuff was not inferior to the agreement of intermittent arm cuff oscillometry. Continuous measurements using a finger cuff can interchangeably be used as an alternative for intermittent arm cuff oscillometry in haemodynamically stable patients, with the advantage of beat-to-beat haemodynamic monitoring. NCT 01362335 (clinicaltrials.gov). © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Effects of transmural pressure and muscular activity on pulse waves in arteries.

    Science.gov (United States)

    Rachev, A I

    1980-05-01

    Propagation of small amplitude harmonic waves through a viscous incompressible fluid contained in an initially stressed elastic cylindrical tube is considered as a model of the pulse wave propagation in arteries. The nonlinearity and orthotropy of the vascular material is taken into account. Muscular activity is introduced by means of an "active" tension in circumferential direction of the vessel. The frequency equation is obtained and it is solved numerically for the parameters of a human abdominal aorta. Conclusions concerning pressure-dependence, age-dependence, and muscular activation-dependence of the wave characteristics are drawn which are in accord with available experimental data.

  6. Association of circulating omentin-1 level with arterial stiffness and carotid plaque in type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Yoo Hye

    2011-11-01

    Full Text Available Abstract Background Adipokines contribute directly to the atherosclerotic process, connecting metabolic disorders such as obesity and diabetes to cardiovascular disease. Omentin-1 is a recently discovered novel adipokine, so data about the relationship of this adipokine to vascular health in type 2 diabetes is limited. Methods We enrolled 60 people with type 2 diabetes, with or without carotid plaque, and 30 participants with normal glucose tolerance. We measured serum omentin-1, high-sensitivity C-reactive protein (hsCRP levels, and the homeostasis model assessment of insulin resistance (HOMA-IR, as well as other cardiovascular risk factors. Vascular health was assessed by brachial ankle pulse wave velocity (baPWV and carotid intima-media thickness (IMT. Results Serum omentin-1 levels were significantly decreased in type 2 diabetes patients compared to normal glucose controls and was further reduced in type 2 diabetes patients with carotid plaque compared to those without carotid plaque. Multiple stepwise regression analysis showed that age, systolic blood pressure, history of use of statins, angiotensin receptor blockers or angiotensin-converting enzyme inhibitors, and serum omentin-1 level were independent factors determining baPWV in people with type 2 diabetes (r2 = 0.637. Furthermore, in multivariate logistic regression analysis, circulating omentin-1 level was an independent decisive factor for the presence of carotid plaque in type 2 diabetes patients, even after adjusting for age, gender, body mass index, systolic blood pressure, fasting blood glucose, low density lipoprotein cholesterol, and history of smoking and medication (odds ratio, 0.621; 95% confidence interval, 0.420-0.919; P = 0.017. Conclusions Circulating omentin-1 level was independently correlated with arterial stiffness and carotid plaque in type 2 diabetes, even after adjusting for other cardiovascular risk factors and detailed medication history.

  7. Relação da cintura abdominal com a condição nutricional, perfil lipídico e pressão arterial em pré-escolares de baixo estrato socioeconômico Relationship between waist circumference and nutritional status, lipid profile and blood pressure in low socioeconomic level pre-school children

    Directory of Open Access Journals (Sweden)

    Roseli Saccardo Sarni

    2006-08-01

    Full Text Available OBJETIVO: Avaliar o diagnóstico nutricional, o perfil lipídico, os níveis pressóricos e a medida de cintura em pré-escolares. Pretende-se ainda verificar se a medida de cintura está associada com índices antropométricos usuais no diagnóstico nutricional, perfil lipídico e pressão arterial em crianças obesas e eutróficas. MÉTODOS: Estudo transversal realizado com 65 pré-escolares de baixo estrato socioeconômico, em escola municipal de Santo André. As avaliações clínico-laboratoriais consistiram em: medida de PA (Task Force, 1996, peso (P e estatura (E expressos como escore z (OMS, 1995 e IMC (índice de massa corpórea; níveis séricos de triglicérides, colesterol total e frações (VLDL-c, HDL-c, LDL-c (Kwiterowich e AHA. Análise estatística: Teste exato de Fisher e correlação. RESULTADOS: Observamos alto porcentual de inadequação da PA e lipídios séricos, independentemente da condição nutricional. A medida de cintura mostrou correlação positiva e significante com IMC e ZPE (r = 0,87 e r = 0,83; p OBJECTIVE: To evaluate anthropometric data, blood lipid levels, blood pressure (BP and waist circumference (WC in preschool children. To relate WC with blood lipid levels and BP in obese and non-obese children. METHODS: In a transversal study we investigated 65 preschool children of low socioeconomic level in Santo André, São Paulo. The evaluation consisted of BP measurement (Task Force, 1996, weight (W, height (H expressed as z score (WHO,1995 and body mass index (BMI, triglycerides, total and fractions of cholesterol blood levels (Kwiterovich and AHA. Statistical analysis: Fisher test and correlations. RESULTS: We observed high BP and lipid levels unrelated to nutritional status. WC was significantly and positively correlated to BMI and ZWH (r = 0,87 and r = 0,83, respectively. Using as a cut-off 75 percentile of WC we found an accuracy of 89,1% with 87,2% specificity and 70,6% sensitivity and predictive value

  8. A rapid decrease in pulmonary arterial pressure by noninvasive positive pressure ventilation in a patient with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Dursunoglu Nese

    2007-01-01

    Full Text Available The natural history of chronic obstructive pulmonary disease (COPD is characterized by progressive decrements in expiratory airflow, increments in end-expired pulmonary volume, hypoxaemia, hypercapnia and the progression of pulmonary arterial hypertension (PAH. Noninvasive positive pressure ventilation (NPPV treatment is increasingly used for the treatment of acute and chronic respiratory failure in patients with COPD. NPPV can increase PaO2 and decrease PaCO2 by correcting the gas exchange in such patients. The acute effect of NPPV on decreasing PAP is seen in patients with respiratory failure, probably due to the effect on cardiac output. Here, a case with COPD whose respiratory acidosis and PAH rapidly improved by NPPV was presented and therefore we suggested to perform an echocardiographic assessment to reveal an improvement of PAH as well as respiratory acidosis, hypercapnia and hypoxemia with that treatment.

  9. Effect of beta-1-blocker, nebivolol, on central aortic pressure and arterial stiffness in patients with essential hypertension

    Directory of Open Access Journals (Sweden)

    Radhika Soanker

    2012-01-01

    Conclusion: Nebivolol 5 mg demonstrated antihypertensive efficacy in patients with essential hypertension by reducing not only peripheral brachial pressures, but also significantly reducing central aortic pressures, augmentation index, and carotid femoral pulse wave velocity, which is the marker of arterial stiffness.

  10. Validation of noninvasive pulse contour cardiac output using finger arterial pressure in cardiac surgery patients requiring fluid therapy

    NARCIS (Netherlands)

    Hofhuizen, C.M.; Lansdorp, B.; Hoeven, J.G. van der; Scheffer, G.J.; Lemson, J.

    2014-01-01

    INTRODUCTION: Nexfin (Edwards Lifesciences, Irvine, CA) allows for noninvasive continuous monitoring of blood pressure (ABPNI) and cardiac output (CONI) by measuring finger arterial pressure (FAP). To evaluate the accuracy of FAP in measuring ABPNI and CONI as well as the adequacy of detecting

  11. Validation of noninvasive pulse contour cardiac output using finger arterial pressure in cardiac surgery patients requiring fluid therapy

    NARCIS (Netherlands)

    Hofhuizen, Charlotte; Lansdorp, Benno; van der Hoeven, Johannes G.; Scheffer, Gert-Jan; Lemson, Joris

    2014-01-01

    Introduction Nexfin (Edwards Lifesciences, Irvine, CA) allows for noninvasive continuous monitoring of blood pressure (ABPNI) and cardiac output (CONI) by measuring finger arterial pressure (FAP). To evaluate the accuracy of FAP in measuring ABPNI and CONI as well as the adequacy of detecting

  12. Ex Vivo and in Silico Study of Human Common Carotid Arteries Pressure Response in Physiological and Inverted State

    Science.gov (United States)

    Piechna, A.; Cieślicki, K.; Lombarski, L.; Ciszek, B.

    2015-02-01

    Arterial walls are a multilayer structures with nonlinear material characteristics. Furthermore, residual stresses exist in unloaded state (zero-pressure condition) and they affect arterial behavior. To investigate these phenomena a number of theoretical and numerical studies were performed, however no experimental validation was proposed and realized yet. We cannot get rid of residual stresses without damaging the arterial segment. In this paper we propose a novel experiment to validate a numerical model of artery with residual stresses. The inspiration for our study originates from experiments made by Dobrin on dogs' arteries (1999). We applied the idea of turning the artery inside out. After such an operation the sequence of layer is reversed and the residual stresses are re-ordered. We performed several pressure-inflation tests on human Common Carotid Arteries (CCA) in normal and inverted configurations. The nonlinear responses of arterial behavior were obtained and compared to the numerical model. Computer simulations were carried out using the commercial software which applied the finite element method (FEM). Then, these results were discussed.

  13. Determination of optimum pressurizer level for kori unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Song, Dong Soo; Lee, Chang Sup; Lee Jae Yong; Kim, Yo Han; Lee, Dong Hyuk [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    To determine the optimum pressurizer water level during normal operation for Kori unit 1, performance and safety analysis are performed. The methodology is developed by evaluating {sup d}ecrease in secondary heat removal{sup e}vents such as Loss of Normal Feedwater accident. To demonstrate optimum pressurizer level setpoint, RETRAN-03 code is used for performance analysis. Analysis results of RETRAN following reactor trip are compared with the actual plant data to justify RETRAN code modelling. The results of performance and safety analyses show that the newly established level setpoints not only improve the performance of pressurizer during transient including reactor trip but also meet the design bases of the pressurizer volume and pressure. 6 refs., 5 figs. (Author)

  14. Creatine kinase inhibition lowers systemic arterial blood pressure in spontaneously hypertensive rats: a randomized controlled trial.

    Science.gov (United States)

    Karamat, Fares A; Oudman, Inge; Haan, Yentl C; van Kuilenburg, Andre B P; Leen, Rene; Danser, Jan A H; Leijten, Frank P J; Ris-Stalpers, Carrie; van Montfrans, Gert A; Clark, Joseph F; Brewster, Lizzy M

    2016-12-01

    Creatine kinase is reported to be a main predictor of blood pressure (BP) in the general population, with a strong correlation between resistance artery creatine kinase expression and clinical BP in humans. The enzyme rapidly regenerates ATP near cytoplasmic ATPases involved in pressor responses, including resistance artery contractility and renal sodium retention. Therefore, we assessed whether creatine kinase inhibition reduces BP. We implemented the 'Animal Research: Reporting of In Vivo Experiments' guideline. In a 4-week randomized controlled trial, male 16-week-old spontaneously hypertensive rats (N = 16) were randomly assigned to the specific competitive creatine kinase inhibitor beta-guanidinopropionic acid (3%)-supplemented chow vs. standard chow. BP measured by the tail-cuff method was the main outcome. Other outcomes included vasodilation in isolated arteries and renal renin expression. Creatine kinase inhibition reduced BP safely and reversibly. Mean baseline BP of, respectively, 191.5 (standard error 4.3) mmHg SBP and 143.1 (4.1) mmHg DBP was reduced by, respectively, 42.7 (5.5) mmHg SBP and 35.6 (5.0) mmHg DBP (P creatine kinase inhibition. Our data indicate that modulation of the creatine kinase system is a potential novel treatment target for hypertension.

  15. [Arterial pressure-based cardiac output monitoring: 1. FloTrac sensor and SVV].

    Science.gov (United States)

    Seo, Katsuhiro

    2009-07-01

    FloTrac is a recently introduced semi-invasive arterial pressure-based cardiac output (APCO) monitoring device. The accuracy of a new device is usually evaluated by Bland-Altman method, which shows graphically the mean value of differences between a new method and the reference method (bias), standard deviation of the differences (precision) and limits of agreement or 2 standard deviations. Critchley et al calculated the percentage errors which are two standard deviations divided by mean cardiac output, and proposed that percentage error should be less than 30% as a reliable new method. Cardiac output was measured by FloTrac (APCO) and pulmonary arterial catheter-based thermodilution method (ICO) during off-pump coronary artery bypass and resection of pheochromocytoma, procedures associated with hemodynamically unstable conditions. As algorithm is renewed in a new version of the device, the accuracy of the device is improved; bias, precision and limits of agreement decreased; correlation coefficient increased, and percentage error was assessed to be around 30%. On the other hand, there was a tendency for increased negative bias as cardiac output increased, implying APCO tends to underestimate ICO in high CO ranges. APCO is less invasive and could rapidly respond to fast changes of hemodynamic state. FloTrac is expected to become a reliable cardiac output monitoring device even under hemodynamically unstable conditions. Further improvement of the algorithm is anticipated.

  16. Validation of non-invasive arterial pressure monitoring during carotid endarterectomy.

    Science.gov (United States)

    Heusdens, J F; Lof, S; Pennekamp, C W A; Specken-Welleweerd, J C; de Borst, G J; van Klei, W A; van Wolfswinkel, L; Immink, R V

    2016-09-01

    Patients undergoing carotid endarterectomy require strict arterial blood pressure (BP) control to maintain adequate cerebral perfusion. In this study we tested whether non-invasive beat-to-beat Nexfin finger BP (BPfin) can replace invasive beat-to-beat radial artery BP (BPrad) in this setting. In 25 consecutive patients (median age 71 yr) scheduled for carotid endarterectomy and receiving general anaesthesia, BPfin and BPrad were monitored simultaneously and ipsilaterally during the 30-min period surrounding carotid artery cross-clamping. Validation was guided by the standard set by the Association for the Advancement of Medical Instrumentation (AAMI), which considers a BP monitor adequate when bias (precision) is <5 (8) mm Hg, respectively. BPfin vs BPrad bias (precision) was -3.3 (10.8), 6.1 (5.7) and 3.5 (5.2) mm Hg for systolic, diastolic, and mean BP, respectively. One subject was excluded due to a poor quality BP curve. In another subject, mean BPfin overestimated mean BPrad by 13.5 mm Hg. Mean BPfin could be considered as an alternative for mean BPrad during a carotid endarterectomy, based on the AAMI criteria. In 23 of 24 patients, the use of mean BPfin would not lead to decisions to adjust mean BPrad values outside the predefined BP threshold. NCT01451294. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Blood Pressure Deviations From Optimal Mean Arterial Pressure During Cardiac Surgery Measured With a Novel Monitor of Cerebral Blood Flow and Risk for Perioperative Delirium: A Pilot Study.

    Science.gov (United States)

    Hori, Daijiro; Max, Laura; Laflam, Andrew; Brown, Charles; Neufeld, Karin J; Adachi, Hideo; Sciortino, Christopher; Conte, John V; Cameron, Duke E; Hogue, Charles W; Mandal, Kaushik

    2016-06-01

    The aim of this study was to evaluate whether excursions of blood pressure from the optimal mean arterial pressure during and after cardiac surgery are associated with postoperative delirium identified using a structured examination. Prospective, observational study. University hospital. The study included 110 patients undergoing cardiac surgery. Patients were monitored using ultrasound-tagged near-infrared spectroscopy to assess optimal mean arterial pressure by cerebral blood flow autoregulation monitoring during cardiopulmonary bypass and the first 3 hours in the intensive care unit. The patients were tested preoperatively and on postoperative days 1 to 3 with the Confusion Assessment Method or Confusion Assessment Method for the Intensive Care Unit, the Delirium Rating Scale-Revised-98, and the Mini Mental State Examination. Summative presence of delirium on postoperative days 1 through 3, as defined by the consensus panel following Diagnostic and Statistical Manual of Mental Disorders-IV-TR criteria, was the primary outcome. Delirium occurred in 47 (42.7%) patients. There were no differences in blood pressure excursions above and below optimal mean arterial pressure between patients with and without summative presence of delirium. Secondary analysis showed blood pressure excursions above the optimal mean arterial pressure to be higher in patients with delirium (mean±SD, 33.2±26.51 mmHgxh v 23.4±16.13 mmHgxh; p = 0.031) and positively correlated with the Delirium Rating Scale score on postoperative day 2 (r = 0.27, p = 0.011). Summative presence of delirium was not associated with perioperative blood pressure excursions; but on secondary exploratory analysis, excursions above the optimal mean arterial pressure were associated with the incidence and severity of delirium on postoperative day 2. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. A comparison of differential oscillometric device with invasive mean arterial blood pressure monitoring in intensive care patients.

    Science.gov (United States)

    Jagomägi, Kersti; Talts, Jaak; Tähepõld, Peeter; Raamat, Rein

    2011-05-01

    Non-invasive beat-to-beat mean arterial pressure (MAP) in finger arteries recorded by the differential oscillometric device was compared with MAP recorded invasively from A. radialis in 22 patients after cardiac surgery. Based on all 132 paired measurements, the MAP values measured at the radial artery were 2.7 ± 4.9 mmHg higher than those measured on fingers. Among 22 patients there were 8 patients receiving inotropic support, their difference being 2.1 ± 5.6 mmHg. The present study revealed that the mean discrepancy between the invasive radial pressure and finger pressure was small; however, patient data sets showed marked variability in average pressure differences when examined individually. © 2010 The Authors. Clinical Physiology and Functional Imaging © 2010 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  19. Post-exercise muscle soreness after eccentric exercise: psychophysical effects and implications on mean arterial pressure.

    Science.gov (United States)

    Bajaj, P; Graven-Nielsen, T; Arendt-Nielsen, L

    2001-10-01

    The aim of the study was to examine the time course of changes in pressure pain threshold (PPT), visual analogue scale (VAS) pain and tenderness scores, McGill Pain Questionnaire (MPQ) descriptors, pain areas, skin temperature and mean arterial pressure (MAP) following intensive eccentric exercise. In 11 healthy male subjects, eccentric exercise of the first dorsal interosseous muscle (FDI) of the right hand with 114% maximum voluntary contraction weight (MVC) was used to induce post-exercise muscle soreness (PEMS) in the right hand, while the left hand served as a control. At 24 h to 48 h all the pain profiles indicated the presence of PEMS in the right hand when compared to before exercise (Prole of central mechanisms in the PEMS, thereby giving further insight into clinical aspects of muscle pain.

  20. Left Ventricular Mass index and Pulmonary Artery Pressure in Patients with the Obstructive Sleep Apnea Syndrome

    Directory of Open Access Journals (Sweden)

    Seyed Hashem Sezavar

    2016-07-01

    Full Text Available Background: Sleep apnea is accompanied by some cardiovascular complications. It has even been hypothesized that sleep apnea, itself, can induce some of these complications. Given such controversies, we assessed the left ventricular mass index (LVMI and systolic pulmonary artery pressure in patients with sleep apnea.Methods: Through convenience sampling, 56 patients with the obstructive sleep apnea syndrome (OSAS were included in the present descriptive cross-sectional study. Patients with any past history of hypertension and diabetes mellitus were excluded. The apnea severity was assessed via the polysomnography-derived apnea-hypopnea index (AHI. All the patients underwent transthoracic echocardiography. In this cross-sectional study - data regarding age, gender, smoking, systolic and diastolic blood pressures, polysomnographic parameters (AHI, severity of disease, mean heart rate, mean oxygen saturation [SaO2], lowest SaO2, and duration of SaO2 below 90% [d.SaO2 < 90%], and  echocardiographic parameters (systolic pulmonary artery pressure and LVMI were accumulated and processed.Results: Fifty-two men and 14 women at a mean age of 49.29 ± 11.79 years participated in this study. Systolic and was significantly high in the severe group compared with the mild group (128.21 ± 9.73 mmHg vs. 119.23 ± 12.5 mmHg; p value = 0.007. The LVMI was increased parallel to an increase in the severity of the OSAS, but that increase was not statistically significant (p value = 0.161. The d.SaO2 < 90% was positively correlated with the LVMI, and this relationship remained true after adjustment for the body mass index (r = 0.27; p value = 0.042.Conclusion: Severe OSAS was accompanied by a higher blood pressure. The LVMI did not differ significantly between the patients with the OSAS and those who did not suffer from other risk factors of cardiac diseases.

  1. Estimating Arterial Partial Pressure of Carbon Dioxide in Ventilated Patients: How Valid Are Surrogate Measures?

    Science.gov (United States)

    Nassar, Boulos S; Schmidt, Gregory A

    2017-06-01

    The arterial partial pressure of carbon dioxide (PaCO2) is an important parameter in critically ill, mechanically ventilated patients. To limit invasive procedures or for more continuous monitoring of PaCO2, clinicians often rely on venous blood gases, capnography, or transcutaneous monitoring. Each of these has advantages and limitations. Central venous Pco2 allows accurate estimation of PaCO2, differing from it by an amount described by the Fick principle. As long as cardiac output is relatively normal, central venous Pco2 exceeds the arterial value by approximately 4 mm Hg. In contrast, peripheral venous Pco2 is a poor predictor of PaCO2, and we do not recommend using peripheral venous Pco2 in this manner. Capnography offers measurement of the end-tidal Pco2 (PetCO2), a value that is close to PaCO2 when the lung is healthy. It has the advantage of being noninvasive and continuously available. In mechanically ventilated patients with lung disease, however, PetCO2 often differs from PaCO2, sometimes by a large degree, often seriously underestimating the arterial value. Dependence of PetCO2 on alveolar dead space and ventilator expiratory time limits its value to predict PaCO2. When lung function or ventilator settings change, PetCO2 and PaCO2 can vary in different directions, producing further uncertainty. Transcutaneous Pco2 measurement has become practical and reliable. It is promising for judging steady state values for PaCO2 unless there is overt vasoconstriction of the skin. Moreover, it can be useful in conditions where capnography fails (high-frequency ventilation) or where arterial blood gas analysis is burdensome (clinic or home management of mechanical ventilation).

  2. Sleep-disordered breathing is associated with blood pressure and carotid arterial stiffness in obese children.

    Science.gov (United States)

    Tagetti, Angela; Bonafini, Sara; Zaffanello, Marco; Benetti, Maria V; Vedove, Francesco Dalle; Gasperi, Emma; Cavarzere, Paolo; Gaudino, Rossella; Piacentini, Giorgio; Minuz, Pietro; Maffeis, Claudio; Antoniazzi, Franco; Fava, Cristiano

    2017-01-01

    Both sleep-disordered breathing (SDB) and high blood pressure (BP) occur more frequently among obese children than among normal weight children, and this may be due to endothelial dysfunction and worsened arterial stiffness. The aim of this study was to evaluate the possible association between SDB and BP, and the possible role of endothelial function and local and systemic arterial stiffness in a sample of obese children asymptomatic for sleep disturbances. Thirty-nine obese children were included in the study. Children underwent overnight limited channel polysomnography, and the vascular measurements included the following: office and 24-h ambulatory BP; brachial flow-mediated dilatation, carotid intima-media thickness and carotid distensibility measured using ultrasound; and systemic arterial stiffness index measured using digital volume pulse analysis. Significant correlations between different BP measurements (both office and ambulatory BP monitoring and estimated by Z score) and SDB were found, including correlations involving the respiratory disturbance index, the apnea-hypopnea index (AHI), the number of desaturations per hour and the mean peripheral saturation (r ranging between 0.330 and 0.474). Carotid distensibility was correlated with the AHI (r = -0.367; P = 0.030) and with the mean oxygen saturation (r = 0.401; P = 0.017). In contrast, there was no relationship among flow-mediated dilatation, stiffness index, carotid intima-media thickness and all the tested respiratory markers. In the multivariate analysis, the supine Z SBP remained independently associated with the number of desaturations per hour and the AHI, even after correction for carotid distensibility and BMI. Our data suggest that in obese children asymptomatic for sleep respiratory problems, SDB might worsen BP, in part, through an increase in arterial stiffness.

  3. Blood pressure monitoring during arrhythmia: agreement between automated brachial cuff and intra-arterial measurements.

    Science.gov (United States)

    Lakhal, K; Ehrmann, S; Martin, M; Faiz, S; Réminiac, F; Cinotti, R; Capdevila, X; Asehnoune, K; Blanloeil, Y; Rozec, B; Boulain, T

    2015-10-01

    Since arrhythmia induces irregular pulse waves, it is widely considered to cause flawed oscillometric brachial cuff measurements of blood pressure (BP). However, strong data are lacking. We assessed whether the agreement of oscillometric measurements with intra-arterial measurements is worse during arrhythmia than during regular rhythm. Among patients of three intensive care units (ICUs), a prospective comparison of three pairs of intra-arterial and oscillometric BP readings was performed among patients with arrhythmia and an arterial line already present. After each inclusion in the arrhythmia group, one patient with regular rhythm was included as a control. International Organization for Standardization (ISO) standard validation required a mean bias arterial measurements of systolic, diastolic and mean BP was similar to that observed in 136 patients with regular rhythm: for mean BP, similar mean bias [-0.1 (sd 5.2) and 1.9 (sd 5.9) mm Hg]. In both groups, the ISO standard was satisfied for mean and diastolic BP, but not for systolic BP (sd >10 mm Hg) in our ICU population. The ability of oscillometry to detect hypotension (systolic BP 10% increase in mean BP after cardiovascular intervention) and hypertension (systolic BP >140 mm Hg) was good and similar during arrhythmia and regular rhythm (respective areas under the receiver operating characteristic curves ranging from 0.89 to 0.96, arrhythmia vs regular rhythm between-group comparisons all associated with P>0.3). Contrary to widespread belief, arrhythmia did not cause flawed automated brachial cuff measurements. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Comparing the Planned Respiratory Cares and CPAP on Atelectasis and Arterial Blood Oxygen Levels of patients undergoing Coronary Artery Bypass Graft

    Directory of Open Access Journals (Sweden)

    Pouya Farokhnezhad Afshar

    2016-09-01

    Full Text Available This study aimed to investigate the effects of planned respiratory cares and Continuous Positive Airway Pressure (CPAP on atelectasis and arterial blood oxygen levels in Coronary Artery Bypass Graft (CABG patients. pulmonary complications and oxygenation impairment after Coronary Artery Bypass Surgery (CABS are prevalent and lead to increased hospitalization and treatment costs. Planned respiratory cares and the application of ventilation with CPAP mode are among the proceedings that are conducted in most of the health centers, but there are not sufficient scientific evidences to confirm the effectiveness of one of these proceedings after CABS. The preset study was a three-group clinical trial with the sample size of 120 patients (40 patients in each group candidate for CABG based on permuted-block randomization. This study was conducted at ShahidRajaei Hospital, Iran in 2015. Patients in experimental group (1 received planned respiratory cares; patient in experimental group (2 received noninvasive ventilation with CPAP mode and; patients in control group received conventional respiratory cares. Other treatments were similar for all three groups. The groups of interest were compared regarding the percentages of measured arterial oxygen saturation before surgery and days one, two, and three after surgery. Also, chest X-rays of patients both before and after surgery (day 3 were compared in terms of atelectasis. Data were analyzed by SPSS 16 using Chi-square tests, KruskalWallis, and Friedman. the results showed that there is not any significant difference between three groups in terms of demographic variables, disease background, and arterial oxygen saturation values before surgery. In day (1, before intervention in patients of group 3, the arterial oxygen saturation values were higher compared to other two groups (p=0.03 and (p=0.001. In the case of atelectasis incidence, patients in group 2 had lowest incidence rate compared to other groups

  5. Eastern Equatorial Pacific Sea Level Pressure (1949-present)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This is one of the CPC?s Monthly Atmospheric and SST Indices. It contains standardized sea level pressure anomalies over the equatorial eastern Pacific region...

  6. Climate Prediction Center Tahiti Sea Level Pressure (1951-present)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This is one of the CPC?s Monthly Atmospheric and SST Indices. It contains Tahiti sea level pressures and anomalies during 1951-present. The anomalies are departures...

  7. Climate Prediction Center Indonesia Sea Level Pressure (1949-present)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This is one of the CPC?s Monthly Atmospheric and SST Indices. It contains standardized sea level pressure anomalies over the equatorial Indonesia region...

  8. Effects of different mean arterial pressure levels on hemodynamics, tissue perfusion and oxygen metabolism in elderly patients with septic shock%不同动脉压水平对老年感染性休克患者血流动力学组织灌注和代谢的影响

    Institute of Scientific and Technical Information of China (English)

    李茂琴; 王惠敏; 许继元; 李家琼; 许艳军; 莫逊; 卢飞; 李琳; 张舟; 李松梅

    2008-01-01

    目的 观察应用去甲肾上腺素联合多巴酚丁胺(NE+Dobu)在小同平均动脉压(MAP)水平对老年感染件休克患者血流动力学、组织灌注和代谢的影响. 方法 感染性休克患者18例,充分液体复苏后为基础状态,应用NE+Dobu并随机调节剂量,使MAP分别维持在65、75、85mm Hg 3种水平状态,持续4 h,观察不同MAP水平的血流动力学、氧合指标、血乳酸、肾功能和胃黏膜二氧化碳分压变化. 结果 当MAP达75 mm Hg和85 mm Hg时,心脏指数(4.7±0.6和5.1±0.7)、体循环阻力指数(1162±278和1276±319)、氧输送[(697±53)ml·min-1·m-2和(711±68)ml·min-1·m-2]、氧摄取率[(0.28±0.02)%和(0.27±0.02)%],均较MAP为65 mm Hg时[4.0±0.6、1011±225、(634±70)ml·min-1·m-2、(0.25±0.02)%]明显增加(P. min Norepinephrine was titrated to maintain MAP at levels of 65 mm Hg, 75 mm Hg and 85 mmHg. Four hours later, the changes of hemodynamics, oxygenation index, blood lactate, renal function and gastric pCO at every MAP level were observed. Results There were no significant differences in heart rate (HR), pulmonary arterial wedge pressure (PAWP), volume of oxygen (VO), Blood lactate, pH value, △pCO and creatinine clearance rate (CCr) among the MAP levels of 65 mm Hg, 75 mm Hg and 85 mm Hg ( all P>0.05). Compared with MAP 65 mm Hg, cardiac index (CI), systemic vascular resistance index (SVRI), oxygen delivery over oxygen extraction ratio were obviously higher at MAP 75 mm Hg and 85 mm Hg [4.7±0.6, 5.1±0.7 vs. 4.0±0.6; 1162±278, 1276±319 vs. 1011±225; (697±53) ml. min. m,(711±68)ml. min. m vs. (634±70) ml · min · m; (0.28±0.02)%,(0.27±0.02)% vs. (0.25±0.02) %, respectively, all P<0.05). The urinary output at MAP levels of 65 mm Hg, 75 mm Hg and 85 mm Hg were (98±43)ml/h, (91±54) ml/h and(74±49)ml/h repectively, and only the differences between MAP 75 mm Hg and MAP 65 mm Hg had statistical significance (P<0.05). Conclusions After aggressive fluid resuscitation

  9. Noninvasively assessed pulsatility of ascending aortic pressure waveform is associated with the presence of coronary artery narrowing.

    Science.gov (United States)

    Wykretowicz, Andrzej; Metzler, Lidia; Milewska, Agata; Balinski, Marek; Rutkowska, Agnieszka; Adamska, Karolina; Krauze, Tomasz; Guzik, Przemysław; Dziarmaga, Mieczysław; Wysocki, Henryk

    2008-01-01

    Several hemodynamic indices, measured invasively in the ascending aorta during routine angiography, are related to the presence and severity of coronary atherosclerosis. Radial artery tonometry, when combined with a validated transfer function, offers the possibility of noninvasive assessment of central arterial pressure. We aim to evaluate the association between noninvasive indices of aortic or radial pressure waveforms and the presence of a significant coronary stenosis. Patients who underwent elective coronary angiography were studied (110 men, 91 women, mean age 53 +/- 0.9 years). Noninvasive measurement of their central hemodynamics was performed by analysis of the aortic pressure waveform derived from the radial artery. An increase in aortic fractional pulse pressure was associated with coronary artery narrowing or previous myocardial infarction. After multivariate adjustment, the odds ratio and confidence intervals (CI) of having a significant coronary aortic stenosis was 1.72 (95% CI, 1.1-2.7) and of previous myocardial infarction 1.6 (95% CI, 1.1-2.2). An increase in noninvasively assessed aortic fractional pulse pressure, but not of the peripheral index is significantly associated with the presence of coronary artery disease.

  10. A pressão arterial está sendo medida? Is the blood pressure being measured?

    Directory of Open Access Journals (Sweden)

    Débora C. Alavarce

    2000-03-01

    Full Text Available A medida da pressão arterial faz parte do exame físico e deve ser realizada em toda consulta médica. Para avaliar se a pressão arterial é medida nas consultas médicas, foram consultados 500 prontuários de pacientes de primeira consulta ambulatorial, sendo 335 (67% provenientes de clínicas médicas e cirúrgicas e 165 (33% das clínicas ginecológica e obstétrica. A pressão arterial foi anotada em 39% das consultas realizadas (135±32/85±19 mm Hg, sendo que em 11% destas anotações a pressão diastólica estava acima de 90 mm Hg. Em relação ao diagnóstico prévio de hipertensão arterial verificou-se que: a em 62% dos prontuários não havia esta informação; b 20% referiram ter hipertensão, e em 79% destes a pressão arterial foi anotada; e c 18% referiram não ter hipertensão e 46% destes tiveram registro da pressão arterial. Portanto, a maior parte dos pacientes não teve sua pressão arterial anotada.The blood pressure measure is part of the physical exam and it should be accomplished in every medical consultation. To verify the blood pressure measured in the accomplished medical consultations record of first they were consulted it consults 500 patient's ambulatorial being 335 (67% coming of medical and surgical clinics and 165 (33% of the gynecological and obstetric clinics. The blood pressure was written down in 39% of the accomplished consultations (135+32 mm Hg 85+19 mm Hg, and 11% of this annotations the pressure diastólica was above 90 mm Hg. In relation to the previous diagnosis of hypertension it was verified that: a in 62% of the records there was not this information; b 20% referred to have hypertension, and in 79% of these the arterial pressure was scored; and c 18% referred not to have hypertension and 46% of these had registration of the arterial pressure. Therefore, most of the patients didn't have its logged arterial pressure.

  11. Theoretical study on the effects of pressure-induced remodeling on geometry and mechanical non-homogeneity of conduit arteries.

    Science.gov (United States)

    Rachev, Alexander; Gleason, Rudolph L

    2011-02-01

    A structure-based mathematical model for the remodeling of arteries in response to sustained hypertension is proposed. The model is based on the concepts of volumetric growth and constitutive modeling of the arterial tissue within the framework of the constrained mixture theory. The major novel result of this study is that remodeling is associated with a local change in the mass fractions of the wall constituents that ultimately leads to mechanical non-homogeneity of the arterial wall. In the new homeostatic state that develops after a sustained increase in arterial pressure, the mass fraction of elastin decreases from the intimal side to the adventitial side of arteries, while the collagen fraction manifests an opposite trend. The results obtained are supported by some experimental observations reported in the literature.

  12. Effect of Chinese herbal medicine for calming Gan (肝) and suppressing hyperactive yang on arterial elasticity function and circadian rhythm of blood pressure in patients with essential hypertension.

    Science.gov (United States)

    Zhong, Guang-wei; Chen, Min-jing; Luo, Yan-hong; Xiang, Ling-li; Xie, Qi-ying; Li, Yun-hui; Zhang, Chen; Gao, Feng

    2011-06-01

    To observe the effect of Chinese herbal medicine for calming Gan (肝) and suppressing hyperactive yang (平肝潜阳, CGSHY) on arterial elasticity function and the circadian rhythm of blood pressure in patients with essential hypertension (EH). Adopting a parallel, randomized design, sixty-four patients with EH of stages I and II were randomly divided into two groups according to a random number table, with 32 in each group. The patients in the treatment group were treated with CGSHY and those in the control group were treated with Enalapril. All patients were given 24-h ambulatory blood pressure monitoring (ABPM) before and after a 12-week treatment. Trough/peak (T/P) ratios of systolic and diastolic blood pressure (SBP & DBP) of each group were calculated. The circadian rhythm of their blood pressure was observed at the same time. The changes in elasticity of the carotid artery in the patients, including stiffness parameter (β), pressure-strain elastic modulus (Ep), arterial compliance (AC), augmentation index (AI), and pulse wave velocity (PVWβ) were determined by the echo-tracking technique before and after a 12-week treatment. In the meantime, their levels of nitric oxide (NO) and endothelin-1 (ET-1) were measured respectively. After treatment, all parameters in the 24-h ABPM and the elasticity of the carotid artery (β, Ep, AC and PVWβ) were markedly improved, the level of NO was increased, and ET-1 was decreased in both groups as compared with values before treatment (Pmonitoring and the elasticity of the carotid artery, the recovery of blood pressure circadian rhythm, and the therapeutic effect of antihypertension in EH patients between the two groups (P>0.05). Chinese herbal medicine for CGSHY may lower the blood pressure smoothly and recover the circadian rhythm of blood pressure in EH patients. They may also improve the carotid elasticity of EH patients similar to that of Enalapril. The mechanism of action of Chinese herbs on EH might be related to

  13. Heat stress attenuates the increase in arterial blood pressure during the cold pressor test.

    Science.gov (United States)

    Cui, Jian; Shibasaki, Manabu; Low, David A; Keller, David M; Davis, Scott L; Crandall, Craig G

    2010-11-01

    The mechanisms by which heat stress impairs the control of blood pressure leading to compromised orthostatic tolerance are not thoroughly understood. A possible mechanism may be an attenuated blood pressure response to a given increase in sympathetic activity. This study tested the hypothesis that whole body heating attenuates the blood pressure response to a non-baroreflex-mediated sympathoexcitatory stimulus. Ten healthy subjects were instrumented for the measurement of integrated muscle sympathetic nerve activity (MSNA), mean arterial blood pressure (MAP), heart rate, sweat rate, and forearm skin blood flow. Subjects were exposed to a cold pressor test (CPT) by immersing a hand in an ice water slurry for 3 min while otherwise normothermic and while heat stressed (i.e., increase core temperature ~0.7°C via water-perfused suit). Mean responses from the final minute of the CPT were evaluated. In both thermal conditions CPT induced significant increases in MSNA and MAP without altering heart rate. Although the increase in MSNA to the CPT was similar between thermal conditions (normothermia: Δ14.0 ± 2.6; heat stress: Δ19.1 ± 2.6 bursts/min; P = 0.09), the accompanying increase in MAP was attenuated when subjects were heat stressed (normothermia: Δ25.6 ± 2.3, heat stress: Δ13.4 ± 3.0 mmHg; P < 0.001). The results demonstrate that heat stress can attenuate the pressor response to a sympathoexcitatory stimulus.

  14. Effects of vascular structures on the pressure drop in stenotic coronary arteries

    Science.gov (United States)

    Kim, Jaerim; Choi, Haecheon; Kweon, Jihoon; Kim, Young-Hak; Yang, Dong Hyun; Kim, Namkug

    2016-11-01

    A stenosis, which is a narrowing of a blood vessel, of the coronary arteries restricts the flow to the heart and it may lead to sudden cardiac death. Therefore, the accurate determination of the severity of a stenosis is a critical issue. Due to the convenience of visual assessments, geometric parameters such as the diameter stenosis and area stenosis have been used, but the decision based on them sometimes under- or overestimates the functional severity of a stenosis, i.e., pressure drop. In this study, patient-specific models that have similar area stenosis but different pressure drops are considered, and their geometries are reconstructed from the coronary computed tomography angiography (CCTA). Both steady and pulsatile inflows are considered for the simulations. Comparison between two models that have a bifurcation right after a stenosis shows that the parent to daughter vessel angle results in different secondary flow patterns and wall shear stress distributions which affect the pressure downstream. Thus, the structural features of the lower and upper parts of a stenosis significantly affect the pressure drop. Supported by 20152020105600.

  15. Influence of changes in the pulmonary artery pressure on ventilation requirements in patients undergoing mitral valve replacement.

    Directory of Open Access Journals (Sweden)

    Muralidhar K

    2004-01-01

    Full Text Available The study was designed to evaluate the influence of changes in pulmonary artery pressure on the ventilation requirements in patients undergoing mitral valve surgery. Thirty patients with mitral valve disease with significant pulmonary arterial hypertension undergoing mitral valve replacement under cardiopulmonary bypass were included in this prospective study. All patients had a pulmonary artery catheter placed after the anaesthetic induction. The minute ventilation was adjusted to achieve an arterial carbon dioxide tension (PaCO2 of 35-40 mm Hg. After a stabilisation period of 15 minutes, the pulmonary artery pressure and the minute volume needed for maintaining a PaCO2 of 35-40 mm Hg in the precardiopulmonary bypass, post-cardiopulmonary bypass and six hours postoperatively were measured after ensuring stable haemodynamics and normothermia. There was a significant decrease in the mean pulmonary artery pressure from pre-cardiopulmonary bypass value of 41.3+/-15 mm Hg to 29.3+/-8 mm Hg in the postcardiopulmonary bypass period and subsequently to 25.5+/-7 mm Hg in the intensive care unit. There was a corresponding increase in the minute volume requirements from a pre-cardiopulmonary bypass value of 6.8+/-1 L/min to 8.0+/-1 L/min in the post cardiopulmonary bypass period and then to 9.4+/-1.2 L/min in the postoperative period. We conclude that there is a significant decrease in the pulmonary blood volume and a subsequent decrease in the pulmonary artery pressure after a successful mitral valve replacement in patients with pulmonary arterial hypertension. This is associated with a significant increase in the requirement of minute ventilation to maintain normocarbia.

  16. Role of the Renin-Angiotensin-Aldosterone System beyond Blood Pressure Regulation: Molecular and Cellular Mechanisms Involved in End-Organ Damage during Arterial Hypertension.

    Science.gov (United States)

    Muñoz-Durango, Natalia; Fuentes, Cristóbal A; Castillo, Andrés E; González-Gómez, Luis Martín; Vecchiola, Andrea; Fardella, Carlos E; Kalergis, Alexis M

    2016-06-23

    Arterial hypertension is a common condition worldwide and an important predictor of several complicated diseases. Arterial hypertension can be triggered by many factors, including physiological, genetic, and lifestyle causes. Specifically, molecules of the renin-angiotensin-aldosterone system not only play important roles in the control of blood pressure, but they are also associated with the genesis of arterial hypertension, thus constituting a need for pharmacological interventions. Chronic high pressure generates mechanical damage along the vascular system, heart, and kidneys, which are the principal organs affected in this condition. In addition to mechanical stress, hypertension-induced oxidative stress, chronic inflammation, and the activation of reparative mechanisms lead to end-organ damage, mainly due to fibrosis. Clinical trials have demonstrated that renin-angiotensin-aldosterone system intervention in hypertensive patients lowers morbidity/mortality and inflammatory marker levels as compared to placebo patients, evidencing that this system controls more than blood pressure. This review emphasizes the detrimental effects that a renin-angiotensin-aldosterone system (RAAS) imbalance has on health considerations above and beyond high blood pressure, such as fibrotic end-organ damage.

  17. Role of the Renin-Angiotensin-Aldosterone System beyond Blood Pressure Regulation: Molecular and Cellular Mechanisms Involved in End-Organ Damage during Arterial Hypertension

    Science.gov (United States)

    Muñoz-Durango, Natalia; Fuentes, Cristóbal A.; Castillo, Andrés E.; González-Gómez, Luis Martín; Vecchiola, Andrea; Fardella, Carlos E.; Kalergis, Alexis M.

    2016-01-01

    Arterial hypertension is a common condition worldwide and an important predictor of several complicated diseases. Arterial hypertension can be triggered by many factors, including physiological, genetic, and lifestyle causes. Specifically, molecules of the renin-angiotensin-aldosterone system not only play important roles in the control of blood pressure, but they are also associated with the genesis of arterial hypertension, thus constituting a need for pharmacological interventions. Chronic high pressure generates mechanical damage along the vascular system, heart, and kidneys, which are the principal organs affected in this condition. In addition to mechanical stress, hypertension-induced oxidative stress, chronic inflammation, and the activation of reparative mechanisms lead to end-organ damage, mainly due to fibrosis. Clinical trials have demonstrated that renin-angiotensin-aldosterone system intervention in hypertensive patients lowers morbidity/mortality and inflammatory marker levels as compared to placebo patients, evidencing that this system controls more than blood pressure. This review emphasizes the detrimental effects that a renin-angiotensin-aldosterone system (RAAS) imbalance has on health considerations above and beyond high blood pressure, such as fibrotic end-organ damage. PMID:27347925

  18. Association of Serum Uric Acid Levels with Leg Ischemia in Patients with Peripheral Arterial Disease after Treatment.

    Science.gov (United States)

    Sotoda, Yoko; Hirooka, Shigeki; Orita, Hiroyuki; Wakabayashi, Ichiro

    2017-07-01

    We investigated the relationships of serum uric acid levels with the progression of atherosclerosis in patients with peripheral arterial disease (PAD) after treatment. Subjects were male patients diagnosed with PAD. Atherosclerosis at the common carotid artery was evaluated based on its intima-media thickness (IMT). Leg arterial flow was evaluated by measuring ankle-brachial index (ABI) and exercise-induced decrease in ABI. Among various risk factors including age, blood pressure, adiposity, estimated glomerular filtration rate, and blood lipid, blood glucose, uric acid, fibrinogen and C-reactive protein levels, only uric acid levels showed significant correlations with ABI [Pearson's correlation coefficient, -0.292 (p<0.01)] and leg exercise-induced decrease in ABI [Pearson's correlation coefficient, 0.236 (p< 0.05)]. However, there was no significant correlation between uric acid levels and maximum or mean IMT. Odds ratios of subjects with the 3rd tertile versus subjects with the 1st tertile for uric acid levels were significantly higher than the reference level of 1.00 for low ABI [4.44 (95% confidence interval, 1.45-13.65, p<0.01)] and for high % decrease in ABI after exercise [4.31 (95% confidence interval, 1.34-13.82, p<0.05)]. The associations of uric acid levels with the indicators of leg ischemia were also found after adjustment for age, history of revascularization therapy, diabetes, smoking, alcohol consumption, body mass index, triglyceride levels, and renal function. Uric acid levels are associated with the degree of leg ischemia in patients with PAD. Further interventional studies are needed to determine whether the correction of uric acid levels is effective in preventing the progression of PAD.

  19. Effect of stellate block on vasomotor factor, vascular endothelial nitricoxide synthase and pulmonary arterial pressure in rabbits with hypoxic pulmonary artery hypertension

    Institute of Scientific and Technical Information of China (English)

    Shunhou He; Qing Li; Sen Chen; Qingxiu Wang

    2007-01-01

    group,hypoxia group and hypoxia + stellate block group, with 6 in each group. Rabbits in the normal control group were perfused with saline through epidural catheter with 0.5 mL once for three times per day and 3 successive days in total; in addition, rabbits in the stellate block group were perfused with 2.5 g/L bupivacaine through epidural catheter with 0.5 mL once for three times per day and 3 successive days in total.Rabbits in the hypoxia group were used to establish hypoxic pulmonary artery hypertension models. That was to say, the experimental rabbits were put in hypoxic box (containing sodalime and calcium chloride to absorb CO2 and water) and given various flows of oxygen and nitrogen through the two lateral wells simultaneously. And then, oxygen was monitored with oxygen-concentration monitoring device to control the concentration in (10±2)% for 8 hours per day and 2 successive weeks in total. Rabbits in the hypoxia +stellate block group were used to establish hypoxia models as the same as those in the hypoxia group. Two weeks later, 2.5 g/L bupivacaine was pushed into epidural catheter with 0.5 mL once for three times per day and 3 successive days in total. Breast was directly opened to measure mean pulmonary artery pressure. ②6 mL blood was collected through pulmonary arterial duct to measure levels of plasma CGRP, prostacyclin,endothelin-1 and thromboxane with radio-immunity technique; meanwhile, immunohistochemical staining was used to observe the changes of BE-NOS content of the experimental rabbits in all groups.MAIN OUTCOME MEASURES: Changes of CGRP, prostacyclin, endothelin-1 and thromboxane and BE-NOS.RESULTS: A total of 24 experimental rabbits were involved in the final analysis. ① As compared with those in the normal control group, hypoxic pulmonary artery hypertension of the experimental rabbits was higher in the hypoxia group and hypoxia + stellate block group after hypoxia [(3.84±0.30), (3.16±0.45),(2.60±0.27) kPa, P < 0.05, 0.01]; CGRP

  20. Decreased plasma urotensin Ⅱ levels inversely correlate with extent and severity of coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Objective To determine the plasma urolensin Ⅱ(UⅡ) levels in various types of coronary heart disease and to clarify how the plasma UⅡ levels correlate with the clinical presentation, extent and severity of coronary artery atherosclerosis (CAD). Methods: One hundred and three aged patients undergoing elective diagnostic coronary angiography for proven or clinical suspected coronary heart disease were enrolled in this study. The extent and severity of coronary artery disease were evaluated by vessel score and Gensini score, respectively. Plasma UⅡ levels were measured by radioimmunoassay. Results: The plasma UⅡ levels in the patients with modest to severe coronary stenosis (3.03±0.34 pg/ml, 1.83±0.67 pg/ml) were significantly lower than that in subjects with normal coronary artery (4.80±1.11 pg/ml, P<0.001). The plasma UⅡ levels in patients with coronary heart disease were also significantly lower than that in patients with insignificant coronary stenosis (P < 0.001). Compared to patients with stable angina pectoris, plasma UⅡ levels in patients with acute coronary syndrome were significantly decreased (1.89±0.51 pg/ml vs 2.42±0.77 pg/ml, P< 0.001). Plasma UⅡ levels were found to be negatively correlated with the severity of coronary artery stenosis (r = -0.488, P<0.001), as well as the vessel score (r = -0.408, P<0.05) in the patients with CAD. Conclusion: Significant inverse correlations exist between the plasma UⅡ levels, and the extent and severity of coronary artery stenosis. These findings suggest that plasma UⅡ contribute to the development and progression of coronary artery stenosis, and may be a novel marker to predict clinical types, as well as the extent and severity of coronary artery disease in the patients.

  1. Continuous Non-Invasive Arterial Pressure Technique Improves Patient Monitoring during Interventional Endoscopy

    Directory of Open Access Journals (Sweden)

    Sylvia Siebig, Felix Rockmann, Karl Sabel, Ina Zuber-Jerger, Christine Dierkes, Tanja Brünnler, Christian E. Wrede

    2009-01-01

    Full Text Available Introduction: Close monitoring of arterial blood pressure (BP is a central part of cardiovascular surveillance of patients at risk for hypotension. Therefore, patients undergoing diagnostic and therapeutic procedures with the use of sedating agents are monitored by discontinuous non-invasive BP measurement (NIBP. Continuous non-invasive BP monitoring based on vascular unloading technique (CNAP®, CN Systems, Graz may improve patient safety in those settings. We investigated if this new technique improved monitoring of patients undergoing interventional endoscopy. Methods: 40 patients undergoing interventional endoscopy between April and December 2007 were prospectively studied with CNAP® in addition to standard monitoring (NIBP, ECG and oxygen saturation. All monitoring values were extracted from the surveillance network at one-second intervals, and clinical parameters were documented. The variance of CNAP® values were calculated for every interval between two NIBP measurements. Results: 2660 minutes of monitoring were recorded (mean 60.1±34.4 min/patient. All patients were analgosedated with midazolam and pethidine, and 24/40 had propofol infusion (mean 90.9±70.3 mg. The mean arterial pressure for CNAP® was 102.4±21.2 mmHg and 106.8±24.8 mmHg for NIBP. Based on the first NIBP value in an interval between two NIBP measurements, BP values determined by CNAP® showed a maximum increase of 30.8±21.7% and a maximum decrease of 22.4±28.3% (mean of all intervals. Discussion: Conventional intermittent blood pressure monitoring of patients receiving sedating agents failed to detect fast changes in BP. The new technique CNAP® improved the detection of rapid BP changes, and may contribute to a better patient safety for those undergoing interventional procedures.

  2. Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry.

    Science.gov (United States)

    Dueck, Ron; Goedje, Oliver; Clopton, Paul

    2012-04-01

    The Tensys TL-200(®) noninvasive beat-to-beat blood pressure (BP) monitor displays continuous radial artery waveform as well as systolic, mean and diastolic BP from a pressure sensor directly over the radial artery at the wrist. It locates the site of maximal radial pulse signal, determines mean BP from maximal pulse waveform amplitude at optimal artery compression and then derives systolic and diastolic BP. We performed a cross-sectional study of TL-200 BP comparisons with contralateral invasive radial artery (A-Line) BP values in 19 subjects during an average 2.5 h of general anesthesia for a wide range of surgical procedures. Two hundred and fifty random sample pairs/patient resulted in 4,747 systolic, mean and diastolic BP pairs for analysis. A-Line BP ranged from 29 mm Hg diastolic to 211 mm Hg systolic, and heart rate varied between 38 and 210 beats/min. Bland-Altman analysis showed an average 2.3 mm Hg TL-200 versus A-Line systolic BP bias and limits of agreement (1.96 SD) were ± 15.3 mm Hg. Mean BP showed a 2.3 mm Hg TL-200 bias and ± 11.7 mm Hg limits of agreement, while diastolic BP showed a 1.7 mm Hg bias and ± 12.3 mm Hg limits of agreement. Coefficients of determination for TL-200 and A-Line BP regression were r² = 0.86 for systolic, r² = 0.86 for mean, and r² = 80 for diastolic BP, respectively, with no apparent change in correlation at low or high BP. Bland-Altman analysis suggested satisfactory agreement between TL-200 noninvasive beat-to-beat BP and invasive A-Line BP. Paired TL-200/A-Line BP comparisons showed a high coefficient of determination.

  3. Transatrial access for left atrial pressure (LAP) monitoring line placement in arterial switch operation (ASO) in neonates.

    Science.gov (United States)

    Akhtar, Mohammad Irfan; Hamid, Mohammad; Amanullah, Muneer; Ahsan, Khalid

    2013-11-01

    Left Atrial pressure monitoring is a useful and accurate method to guide Left ventricle filling in the patients who undergo Arterial switch operation for transposition of great arteries. We have used a different technique in three TGA patients for LA pressure monitoring line placement. After cleaning and draping,right internal jugular vein (rt IJV) located through 22G venous cannula, guide wire was put in followed by sliding the 22G x 8cm vygon arterial catheter over the guide wire into the right atrium that was directed transatrially into LA by the operating surgeon during atrial septum repair. The catheter was secured by silk on the neck and dressed with transparent dressing and was kept for a period of 48-72 hrs. LA pressure monitoring is helpful in anticipating LV dysfunction in ASO.

  4. The Investigation of Serum Vaspin Level in Atherosclerotic Coronary Artery Disease

    OpenAIRE

    Kobat, Mehmet Ali; Celik,Ahmet; Balin, Mehmet; Altas, Yakup; Baydas, Adil; Bulut, Musa; Aydin, Suleyman; DAGLI, Necati; YAVUZKIR, Mustafa Ferzeyn; Ilhan, Selcuk

    2012-01-01

    Background It was speculated that fatty tissue originated adipocytokines may play role in pathogenesis of atherosclerosis. These adipocytokines may alter vascular homeostasis by effecting endothelial cells, arterial smooth muscle cells and macrophages. Vaspin is a newly described member of adipocytokines family. We aimed to investigate whether plasma vaspin level has any predictive value in coronary artery disease (CAD). Methods Forty patients who have at least single vessel ≥ 70 % stenosis d...

  5. Continuous blood pressure monitoring via non-invasive radial artery applanation tonometry and invasive arterial catheter demonstrates good agreement in patients undergoing colon carcinoma surgery.

    Science.gov (United States)

    Sun, Jing; Chen, Hanjian; Zheng, Jun; Mao, Bin; Zhu, Shengmei; Feng, Jingyi

    2016-12-20

    Radial artery applanation tonometry (RAAT) has been developed and utilized for continuous arterial pressure monitoring. However, evidence is lacking to clinically verify the RAAT technology and identify appropriate patient groups before routine clinical use. This study aims to evaluate the RAAT technology by comparing systolic blood pressure (SBP), mean blood pressure (MBP) and diastolic blood pressure (DBP) values in patients undergoing colon carcinoma surgery. Blood Pressure (BP) values obtained via RAAT (TL-300, Tensys Medical Inc., San Diego, CA, USA) and conventional arterial catheterization from 30 colon carcinoma surgical patients were collected and compared via Bland-Atman method, linear regression and 4-quadrant plot concordance analysis. For SBPs, MBPs and DBPs, means of the differences (±standard deviation; 95% limits of agreement) were -0.9 (±7.6; -15.7 to 13.9) mmHg, 3.1 (±6.5; -9.6 to 15.8) mmHg and 4.3 (±7.4; -10.3 to 18.8) mmHg, respectively. Linear regression coefficients of determination were 0.8706 for SBPs, 0.8353 for MBPs and 0.6858 for DBPs. Four-quadrant concordance correlation coefficients were 0.8740, 0.8522 and 0.7108 for SBPs, MBPs and DBPs, respectively. A highly selected patient collective undergoing colon carcinoma surgery was studied. BP measurements obtained via the TL-300 had clinically acceptable agreement with that acquired invasively using an arterial catheter. For use in clinical routine, it is necessary to take measures for improvement regarding movement artifacts and dilution of noise. A large sample size of patients under various conditions is also needed to further evaluate the RAAT technology before clinically routine use.

  6. Correlation between Serum Level of Adiponectin and Severity of Coronary Artery Atherosclerosis

    Institute of Scientific and Technical Information of China (English)

    Lei Juan; Zhou Shuxian; Xue Shengneng; Zhang Yuling; Fang Chang; Luo Niansang

    2007-01-01

    Objectives To investigate the correlation between serum level of adiponectin and severity of coronary artery atherosclerosis. Methods Coronary angiographies were performed and serum levels of adiponectin were measured in 88 patients with suspected coronary heart disease (CHD). Patients were divided into groups according to the coronary angiographies and Gensini's scores of coronary artery atherosclerosis. The serum levels of adiponectin were compared in different groups, and multiple regressions were used to analyze the correlation factors of adiponectin. Results ①Serum adiponectin concentration in CHD group [ 7.1 mg/L(2.4 ~21.1 mg/L) ] was decreased as compared with that in control group [ 11.6 mg/L(4.4 ~ 28.2 mg/L),P<0.01 ]; ②The serum levels of adiponectin fell while the Gensini' s scores of coronary artery atherosclerosis increased ( P<0.05, P<0.01 ); ③Serum level of adiponectin was positively correlated with the high-density lipoprotein cholesterol, while negatively correlated with the Gensini' s score of coronary artery atherosclerosis and triglyceride (P<0.01 ). Conclusions Serum adiponectin concentration was decreased in patients with CHD.Low serum levels of adiponectin reflected the severity of coronary artery atherosclerosis. Adiponectin was a protective factor of cardiovascular system.

  7. Plasma Tissue Factor Pathway Inhibitor Levels in Angiographically Defined Coronary Artery Disease Among Saudis

    Directory of Open Access Journals (Sweden)

    Syed Shahid Habib

    2013-05-01

    Full Text Available Objectives: This study was aimed to determine plasma levels of total (TFPI-T and free (TFPI-F tissue factor pathway inhibitor, plasminogen activator inhibitor-1 (PAI-1, and tissue plasminogen activator (t-PA in a cohort of Saudi patients with chronic stable angiographically defined coronary artery disease (CAD and to determine its correlation with its severity.Methods: This cross sectional study was conducted in the department of physiology and department of cardiology, College of Medicine, and King Khalid University Hospital and King Saud University, Riyadh. Sixty known cases of CAD who had undergone angiography (35 males and 25 females were selected. A control group included 39 (20 males and 19 females healthy subjects. Fasting venous blood samples were analyzed for total (TFPI-T and free (TFPI-F tissue factor pathway inhibitor, plasminogen activator inhibitor-1 (PAI-1, and tissue plasminogen activator (t-PA. Gensini scores and vessel scores were determined for assessing CAD severity.Results: There were non-significant differences between age, body mass index (BMI and Blood pressure between the controls and CAD subjects. A comparison of hemostatic markers between control and CAD patients showed significantly higher levels of Fibrinogen, PAI-1, TFPI-T and TFPI-F in CAD patients compared to control subjects. But there was no difference in plasma t-PA levels. TFPI-T had a significant positive correlation with severity of disease determined by Gensini Scores (r=0.344; p=0.006 and vessel scores (r=0.338; p=0.015.Conclusion: Plasma levels of total tissue factor pathway inhibitor are significantly related with the presence and severity of CAD. Elevated levels of TFPI-T may be considered as useful diagnostic and prognostic markers in patients with CAD.

  8. Comparison of the effects of antihypertensive agents on central blood pressure and arterial stiffness in isolated systolic hypertension.

    Science.gov (United States)

    Mackenzie, Isla S; McEniery, Carmel M; Dhakam, Zahid; Brown, Morris J; Cockcroft, John R; Wilkinson, Ian B

    2009-08-01

    Isolated systolic hypertension is an important risk factor for cardiovascular disease and results primarily from elastic artery stiffening. Although various drug therapies are used to lower peripheral blood pressure (BP) in patients with isolated systolic hypertension, the effects of the 4 major classes of antihypertensive agents on central BP, pulse pressure (PP) amplification, and arterial stiffness in this condition are not clear. Fifty-nine patients over the age of 60 years with untreated isolated systolic hypertension (systolic BP > or =140 mm Hg and diastolic BP hypertension, the choice of therapy may be influenced by these findings in the future.

  9. Dynamic Changes of Pulmonary Arterial Pressure and Ductus Arteriosus in Human Newborns From Birth to 72 Hours of Age

    OpenAIRE

    2016-01-01

    Abstract Normal pulmonary artery pressure and pulmonary hypertension assessment of newborns is rarely reported. The aim of the study is to explore dynamic changes of pulmonary arterial pressure and ductus arteriosus in human newborns from birth to 72 h of age with echocardiography. A total of 76 cases of normal newborns were prospectively detected by echocardiography after birth of 2 h, 6 h, 12 h, 24 h, 48 h, and 72 h, respectively. Ductus arteriosus diameter, blood shunt direction, blood flo...

  10. Successful treatment of combined vaginal and broad ligament hematoma using pelvic pressure pack and arterial embolization

    Institute of Scientific and Technical Information of China (English)

    Ma Runmei; Lao Terence T; Feng Yukun; Zhao Wei; Huang Jianqiang; Liang GuoHua; Li Hongyu; Chen Zhuo

    2005-01-01

    Objective:To assess using the pelvic pressure pack as temporizing treatment for combined vaginal and broad ligament hematoma before selective arterial embolization could be undertaken.Methods:A 29-year-old woman was transferred because of a 10cm right upper vaginal hematoma found shortly after the spontaneous delivery of a 3400g infant at term.Following evacuation of the clots,the patient's condition deteriorated with the appearance of a painful right pelvic mass,displacing the uterus.At laparotomy,the hematoma extended between the folds of the broad ligament into the pelvic sidewall.After evacuation of the clots,hemostasis failed despite subtotal hysterectomy.Eventually a pressure pack created from joined gauze rolls was used to fill up the pelvic cavity and achieved hemostasis before abdominal closure.When the vaginal pack was removed 30 hours later,vaginal bleeding recurred,and bilateral hypogastric embolization was performed with Gianturco coils.Results:The patient was successfully treated by this way and discharged uneventfully.Conclusion:In combined vaginal and broad ligament hematoma,pelvic pressure pack can be used to ensure maternal survival until definitive treatment with angiographic embolization.

  11. Association of vitamin D status with arterial blood pressure and hypertension risk

    DEFF Research Database (Denmark)

    Vimaleswaran, Karani S; Cavadino, Alana; Berry, Diane J

    2014-01-01

    BACKGROUND: Low plasma 25-hydroxyvitamin D (25[OH]D) concentration is associated with high arterial blood pressure and hypertension risk, but whether this association is causal is unknown. We used a mendelian randomisation approach to test whether 25(OH)D concentration is causally associated...... with blood pressure and hypertension risk. METHODS: In this mendelian randomisation study, we generated an allele score (25[OH]D synthesis score) based on variants of genes that affect 25(OH)D synthesis or substrate availability (CYP2R1 and DHCR7), which we used as a proxy for 25(OH)D concentration. We meta......, -0·12 mm Hg, 95% CI -0·20 to -0·04; p=0·003) and reduced odds of hypertension (odds ratio [OR] 0·98, 95% CI 0·97-0·99; p=0·0003), but not with decreased diastolic blood pressure (β per 10% increase, -0·02 mm Hg, -0·08 to 0·03; p=0·37). In meta-analyses in which we combined data from D...

  12. On the reliability of frequency components in systolic arterial pressure in patients with atrial fibrillation.

    Science.gov (United States)

    Corino, Valentina D A; Lombardi, Federico; Mainardi, Luca T

    2010-04-01

    Atrial fibrillation (AF) is characterized by desynchronization of atrial electrical activity causing a consequent irregular ventricular response. In AF, the beat-to-beat variation of blood pressure is increased because of variations in filling time and contractility. However, only a few studies have analyzed short-term blood pressure variations in AF, and we have recently observed a harmonic low-frequency (LF) component in systolic arterial pressure (SAP) during AF. Aim of the present study is to propose a method to verify the reliability of the spectral component found in SAP series, based on the position of the poles of the autoregressive spectral decomposition in the z-plane. In particular, 1,000 random permutations of the series allowed the definition of an area in the z-plane where poles from random process are likely to occur. Poles lying outside this area are considered as reliable oscillations. We tested the method on 53 recordings obtained at rest from patients with persistent AF. LF component was found in, respectively, 51 and 43 recordings in SAP and RR series. High-frequency (HF) component was found in all the recordings for both SAP and RR series. Using the proposed test, the percentage of reliable components in LF and HF bands was 80 and 38 in SAP series, and 20 and 18 in RR series. We concluded that, at variance with RR ones, SAP LF components are likely to represent true physiological oscillations.

  13. The Correlation between Systolic Blood Pressure Measured by Return to Flow Versus Systolic Blood Pressure Measured by Arterial Catheter in the Adult Anesthetized Patient.

    Science.gov (United States)

    1986-12-01

    a U-tube and mercury manometer for other research, he did not use it to measure arterial blood pressure (30). It was almost a century 34 N N 35 later...use of this mercury manometer decreased the size of the measuring apparatus more than 27 times (30). Carl Ludwig made an important contribution to...direct measurement of blood pressure in 1847 when he added a i graphic recording device to the mercury manometer . This eliminated observer error and

  14. Wall shear stress and pressure distribution on aneurysms and infundibulae in the posterior communicating artery bifurcation.

    Science.gov (United States)

    Baek, Hyoungsu; Jayaraman, Mahesh V; Karniadakis, George Em

    2009-12-01

    A growing number of cases of rupture at an infundibulum, progression of infundibulum to a frank aneurysm, and subarachnoid hemorrhage (SAH) in the posterior communicating artery (PCoA) have been reported. Using patient-specific geometric models of the supraclinoid internal carotid artery (ICA) with PCoA infundibulum or aneurysm, high-resolution computational fluid dynamics simulations were performed by solving the Navier-Stokes equations with a spectral/hp element method. Simulation results show that the flow impinges at the distal wall of infundibulum near the outside of the ICA bend and creates a region of higher pressure (4-5 mmHg) surrounded by a band of a high wall shear stress (WSS) (20-30 N/m(2) on average). At the proximal end of the infundibulum, another stagnation area is formed characterized by low WSS (shear index. This impingement region seems to coincide with the locations of the rupture of infundibulae or progression to aneurysms. In addition, the pulsatile flow becomes unstable due to the presence of aneurysms or aneurysm-like infundibulae, and this leads to WSS temporal fluctuations inside the aneurysm, which may accelerate the degenerative processes in the vessel walls.

  15. Ratio of exercise and recovery systolic blood pressure integrals in prediction of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Jure Mirat

    2009-02-01

    Full Text Available Aim This study was performed to determine whether the ratio (Q =A/B of area A under the curve of exercise systolic blood pressure(SBP increase and area B under curve of recovery SBP decreaseis predictive of angiographic coronary artery disease (CAD.Methods Patients who performed exercise testing and subsequentlyunderwent coronary angiography, within three months, wereanalyzed in this study. According to angiographic report, patientswere divided in three groups: without disease or with stenosis lessthan 50% (group 1, significant (group 2, and severe (group 3.Severe disease was defined as left main, three-vessel or two-vesseldisease with involvement of proximal left anterior descending artery.Results There were 137 patients included in this study (age 59 ±10, 70% male. Group 1 included 57%, group 2 included 30%,and group 3 included 13% of patients. Mean values of the Q ratiowere 2.72 ± 0.9, 1.74 ± 0.76, 1.01 ± 0.38 in groups 1, 2 and 3,respectively. By means of robust discrimination analysis, statisticallysignificant difference between groups 1, 2 and 3 in values ofthe ratio Q (p < 0.001 was found.Conclusion The ratio of exercise SBP increase and recovery SBPdecrease areas under the curve suggests severity of CAD.

  16. Signal quality quantification and waveform reconstruction of arterial blood pressure recordings.

    Science.gov (United States)

    Fanelli, A; Heldt, T

    2014-01-01

    Arterial blood pressure (ABP) is an important vital sign of the cardiovascular system. As with other physiological signals, its measurement can be corrupted by different sources of noise, interference, and artifact. Here, we present an algorithm for the quantification of signal quality and for the reconstruction of the ABP waveform in noise-corrupted segments of the measurement. The algorithm quantifies the quality of the ABP signal on a beat-by-beat basis by computing the normalized mean of successive differences of the ABP amplitude over each beat. In segments of poor signal quality, the ABP wavelets are then reconstructed on the basis of the expected cycle duration and envelope information derived from neighboring ABP wavelet segments. The algorithm was tested on two datasets of ABP waveform signals containing both invasive radial artery ABP and noninvasive ABP waveforms. Our results show that the approach is efficient in identifying the noisy segments (accuracy, sensitivity and specificity over 95%) and reliable in reconstructing beats that were artificially corrupted.

  17. Raynaud's phenomenon is correlated with elevated systolic pulmonary arterial pressure in patients with systemic lupus erythematosus.

    Science.gov (United States)

    Kasparian, A; Floros, A; Gialafos, E; Kanakis, M; Tassiopoulos, S; Kafasi, N; Vaiopoulos, G

    2007-01-01

    In patients with Systemic lupus erythematosus (SLE), Raynaud phenomenon (RP) is frequently present and associated with pulmonary hypertension (PHT). Elevated pulmonary artery systolic pressure (PASP) is an indicator of PHT and can be estimated noninvasively. We attempt to explore the significance of RP in SLE and to correlate it with clinical and serological parameters of the disease. The study population consisted of 34 patients (age, sex and disease duration matched) who fulfilled the revised SLE criteria of the American College of Rheumatology, and were categorized into two groups: Group 1 had patients having SLE and RP (2 males/15 females, mean age 45 +/- 18 years) and group 2 had patients with SLE but without RP (3 males/14 females, mean age 40 +/- 14 years. Detailed cardiac ultrasound was performed including measurement of PASP, while clinical and serological features of both groups were collected and correlated. Significant differences were shown in the presence of arterial hypertension (P < 0.05), arthralgias (P < 0.005), arthritis (P < 0.05), myalgias (P < 0.05), alopecia (P < 0.05) and PASP (P < 0.0001). No difference was observed among the cardiac ultrasound indices and the ejection fraction between the two groups. PASP was significantly correlated with RP, while no correlation was observed regarding the disease duration. In patients with SLE, the presence of RP was associated with elevation in PASP. Further investigation is needed to clarify the significance of this relation.

  18. Multichannel Blind Deconvolution of the Arterial Pressure using Ito Calculus Method

    Directory of Open Access Journals (Sweden)

    M. El-Sayed Waheed

    2015-11-01

    Full Text Available Multichannel Blind Deconvolution (MBD is a powerful tool particularly for the identification and estimation of dynamical systems in which a sensor, for measuring the input, is difficult to place. This paper presents Ito calculus method for the estimation of the unknown time-varying coefficient. The arterial network is modelled as a Finite Impulse Response (FIR filter with unknown coefficients. A new tool for estimation of both the central arterial pressure and the unknown channel dynamics has been developed. The convolution process is modelled as a Finite Impulse Response (FIR filter with unknown coefficients. The source signal is also unknown. Assuming that one of the FIR filter coefficients are time varying, we have been able to get accurate estimation results for the source signal, even though the filter order is unknown. The time varying filter coefficients have been estimated through the SC algorithm, and we have been able to deconvolve the measurements and obtain both the source signal and the convolution path. The positive results demonstrate that the SC approach is superior to conventional methods.

  19. Examining the response pressure along a fluid-filled elastic tube to comprehend Frank's arterial resonance model.

    Science.gov (United States)

    Lin Wang, Yuh-Ying; Sze, Wah-Keung; Lin, Chin-Chih; Chen, Jiang-Ming; Houng, Chin-Chi; Chang, Chi-Wei; Wang, Wei-Kung

    2015-04-13

    Frank first proposed the arterial resonance in 1899. Arteries are blood-filled elastic vessels, but resonance phenomena for a fluid-filled elastic tube has not drawn much attention yet. In this study, we measured the pressure along long elastic tubes in response to either a single impulsive water ejection or a periodic water input. The experimental results showed the low damped pressure oscillation initiated by a single impulsive water input; and the natural frequencies of the tube, identified by the peaks of the response in the frequency domain, were inversely proportional to the length of the tube. We found that the response to the periodic input reached a steady distributed oscillation with the same period of the input after a short transient time; and the optimal pressure response, or resonance, occurred when the pumping frequency was near the fundamental natural frequency of the system. We pointed out that the distributed forced oscillation could also be a suitable approach to analyze the arterial pressure wave. Unlike Frank's resonance model in which the whole arterial system was lumped together to a simple 0-D oscillator and got only one natural frequency, a tube has more than one natural frequency because the pressure P(z,t) is a 1-D oscillatory function of the axial position z and the time t. The benefit of having more than one natural frequency was then discussed.

  20. Favorable effect of aerobic exercise on arterial pressure and aortic pulse wave velocity during stress testing.

    Science.gov (United States)

    Milatz, Florian; Ketelhut, Sascha; Ketelhut, Sascha; Ketelhut, Reinhard G

    2015-07-01

    Increased central pulse wave velocity is a major risk factor for cardiovascular disease. The favorable influence of exercise on arterial stiffness (AS) and blood pressure (BP) has been reported exclusively at rest. The present study investigated the influence of a single bout of acute cycling on AS and BP during recovery and, moreover, during cold pressor stress testing. 32 healthy men (33.7 ± 8 years, BMI 24 ± 2.5 kg/m²) performed a 60 minute endurance exercise on a bicycle ergometer (45 % VO2max). Before and after exercise aortic pulse wave velocity (aPWV) as well as central and peripheral BP were measured non-invasively at rest and at the end of a 2 minute cold pressor test (CPT). Even after 60 minutes of recovery aPWV (- 0.22 ± 0.3 m / sec) was significantly reduced (p testing.

  1. Arterial pressure and cerebral blood flow variability: friend or foe? A review

    Directory of Open Access Journals (Sweden)

    Caroline Alice Rickards

    2014-04-01

    Full Text Available Variability in arterial pressure and cerebral blood flow has traditionally been interpreted as a marker of cardiovascular decompensation, and has been associated with negative clinical outcomes across varying time scales, from impending orthostatic syncope to an increased risk of stroke. Emerging evidence, however, suggests that increased hemodynamic variability may, in fact, be protective in the face of acute challenges to perfusion, including significant central hypovolemia and hypotension (including hemorrhage, and during cardiac bypass surgery. This review presents the dichotomous views on the role of hemodynamic variability on clinical outcome, including the physiological mechanisms underlying these patterns, and the potential impact of increased and decreased variability on cerebral perfusion and oxygenation. We suggest that reconciliation of these two apparently discrepant views may lie in the time scale of hemodynamic variability; short time scale variability appears to be cerebroprotective, while mid to longer term fluctuations are associated with primary and secondary end-organ dysfunction.

  2. A simple model of cerebral blood flow dependence on arterial blood pressure

    CERN Document Server

    Gersten, Alexander

    2011-01-01

    It is shown that the dependence of the cerebral blood flow (CBF) on mean arterial blood pressure (MABP) can be described with a simple model having the following assumptions. Below certain MABP (denoted as MABP1) there are no autoregulatory or feedback mechanisms influencing CBF. Between MABP1 and MABP2 (MABP at which breakthrough accurs) there is a linear (on MABP) dependent feedback with a sloap depending very much on the individual considered. The classical autoregulation model with a plateau in between MABP1 and MABP2 is a particular case of this model. The model describes well the experiments performed on dogs (Harper 1966), for which the individual feedback sloap parameter varied to great extent, indicating the importance of mesurments on individuals against averaged mesurments (or measurments on diffent individuals) which superficially support the classical autoregulation. New effect of decreased CBF, while increasing MABP, was observed.

  3. Effects of Weather and Heliophysical Conditions on Emergency Ambulance Calls for Elevated Arterial Blood Pressure

    Directory of Open Access Journals (Sweden)

    Jone Vencloviene

    2015-02-01

    Full Text Available We hypothesized that weather and space weather conditions were associated with the exacerbation of essential hypertension. The study was conducted during 2009–2010 in the city of Kaunas, Lithuania. We analyzed 13,475 cards from emergency ambulance calls (EACs, in which the conditions for the emergency calls were made coded I.10–I.15. The Kaunas Weather Station provided daily records of air temperature (T, wind speed (WS, relative humidity, and barometric pressure (BP. We evaluated the associations between daily weather variables and daily number of EACs by applying a multivariate Poisson regression. Unfavorable heliophysical conditions (two days after the active-stormy geomagnetic field or the days with solar WS > 600 km/s increased the daily number of elevated arterial blood pressure (EABP by 12% (RR = 1.12; 95% confidence interval (CI 1.04–1.21; and WS ≥ 3.5 knots during days of T < 1.5 °C and T ≥ 12.5 °C by 8% (RR = 1.08; CI 1.04–1.12. An increase of T by 10 °C and an elevation of BP two days after by 10 hPa were associated with a decrease in RR by 3%. An additional effect of T was detected during days of T ≥ 17.5 °C only in females. Women and patients with grade III arterial hypertension at the time of the ambulance call were more sensitive to weather conditions. These results may help in the understanding of the population’s sensitivity to different weather conditions.

  4. Autoregulation of cerebral blood flow to changes in arterial pressure in mild Alzheimer's disease.

    Science.gov (United States)

    Zazulia, Allyson R; Videen, Tom O; Morris, John C; Powers, William J

    2010-11-01

    Studies in transgenic mice overexpressing amyloid precursor protein (APP) demonstrate impaired autoregulation of cerebral blood flow (CBF) to changes in arterial pressure and suggest that cerebrovascular dysfunction may be critically important in the development of pathological Alzheimer's disease (AD). Given the relevance of such a finding for guiding hypertension treatment in the elderly, we assessed autoregulation in individuals with AD. Twenty persons aged 75±6 years with very mild or mild symptomatic AD (Clinical Dementia Rating 0.5 or 1.0) underwent (15)O-positron emission tomography (PET) CBF measurements before and after mean arterial pressure (MAP) was lowered from 107±13 to 92±9 mm Hg with intravenous nicardipine; (11)C-PIB-PET imaging and magnetic resonance imaging (MRI) were also obtained. There were no significant differences in mean CBF before and after MAP reduction in the bilateral hemispheres (-0.9±5.2 mL per 100 g per minute, P=0.4, 95% confidence interval (CI)=-3.4 to 1.5), cortical borderzones (-1.9±5.0 mL per 100 g per minute, P=0.10, 95% CI=-4.3 to 0.4), regions of T2W-MRI-defined leukoaraiosis (-0.3±4.4 mL per 100 g per minute, P=0.85, 95% CI=-3.3 to 3.9), or regions of peak (11)C-PIB uptake (-2.5±7.7 mL per 100 g per minute, P=0.30, 95% CI=-7.7 to 2.7). The absence of significant change in CBF with a 10 to 15 mm Hg reduction in MAP within the normal autoregulatory range demonstrates that there is neither a generalized nor local defect of autoregulation in AD.

  5. Treatment of hypertension and metabolic syndrome: lowering blood pressure is not enough for organ protection, new approach-arterial destiffening.

    Science.gov (United States)

    Zimlichman, Reuven

    2014-10-01

    Cardiovascular risk factors (CVRFs) have been shown to induce end organ damage. Until now, the main approach to reduce CVRF-induced end organ damage was by normalization of CVRFs; this approach was found effective to reduce damage and cardiovascular (CV) events. However, a residual risk always remained even when CVRFs were optimally balanced. An additional risk factor which has an immense effect on the progression of end organ damage is aging. Aging is accompanied by gradual stiffening of the arteries which finally leads to CV events. Until recently, the process of arterial aging was considered as unmodifiable, but this has changed. Arterial stiffening caused by the aging process is similar to the changes seen as a result of CVRF-induced arterial damage. Actually, the presence of CVRFs causes faster arterial stiffening, and the extent of damage is proportional to the severity of the CVRF, the length of its existence, the patient's genetic factors, etc. Conventional treatments of osteoporosis and of hormonal decline at menopause are potential additional approaches to positively affect progression of arterial stiffening. The new approach to further decrease progression of arteriosclerosis, thus preventing events, is the prevention of age-associated arterial structural changes. This approach should further decrease age-associated arterial stiffening. A totally new promising approach is to study the possibility of affecting collagen, elastin, and other components of connective tissue that participate in the process of arterial stiffening. Reduction of pulse pressure by intervention in arterial stiffening process by novel methods as breaking collagen cross-links or preventing their formation is an example of future directions in treatment. This field is of enormous potential that might be revolutionary in inducing further significant reduction of cardiovascular events.

  6. Neural set point for the control of arterial pressure: role of the nucleus tractus solitarius

    Directory of Open Access Journals (Sweden)

    Valentinuzzi Max E

    2010-01-01

    Full Text Available Abstract Background Physiological experiments have shown that the mean arterial blood pressure (MAP can not be regulated after chemo and cardiopulmonary receptor denervation. Neuro-physiological information suggests that the nucleus tractus solitarius (NTS is the only structure that receives information from its rostral neural nuclei and from the cardiovascular receptors and projects to nuclei that regulate the circulatory variables. Methods From a control theory perspective, to answer if the cardiovascular regulation has a set point, we should find out whether in the cardiovascular control there is something equivalent to a comparator evaluating the error signal (between the rostral projections to the NTS and the feedback inputs. The NTS would function as a comparator if: a its lesion suppresses cardiovascular regulation; b the negative feedback loop still responds normally to perturbations (such as mechanical or electrical after cutting the rostral afferent fibers to the NTS; c perturbation of rostral neural structures (RNS to the NTS modifies the set point without changing the dynamics of the elicited response; and d cardiovascular responses to perturbations on neural structures within the negative feedback loop compensate for much faster than perturbations on the NTS rostral structures. Results From the control theory framework, experimental evidence found currently in the literature plus experimental results from our group was put together showing that the above-mentioned conditions (to show that the NTS functions as a comparator are satisfied. Conclusions Physiological experiments suggest that long-term blood pressure is regulated by the nervous system. The NTS functions as a comparator (evaluating the error signal between its RNS and the cardiovascular receptor afferents and projects to nuclei that regulate the circulatory variables. The mean arterial pressure (MAP is regulated by the feedback of chemo and cardiopulmonary receptors and

  7. Sensing arterial CO(2) levels: a role for medullary P2X receptors.

    Science.gov (United States)

    Spyer, K M; Thomas, T

    2000-07-01

    ATP has been shown to act as an excitatory neurotransmitter in the central nervous system. In this review, evidence is presented to indicate that when ATP is micro-injected into the ventrolateral medulla (VLM) of the rat, changes in respiratory activity are elicited. These effects, and accompanying changes in heart rate and blood pressure are mediated by P2X purinoreceptors. Immunocytochemistry indicates a prevalence of P2X(2) and P2X(6) purinoreceptors in this region of the medulla. The P2 purinoceptor antagonists, suramin and PPADS blunt the respiratory responses to changes in arterial CO(2) levels when micro-injected into the VLM. This effect is shown electrophysiologically to be mediated by purinoreceptors located primarily on respiratory neurones of the VLM including the Bötzinger complex. As the effects of agonist activation of P2X(2) purinoceptors expressed in HEK293 cells and Xenopus oocytes are potentiated by lowering pH, these data imply that the central respiratory response to CO(2) depends in part on the pH sensitivity of purinoreceptors located on inspiratory neurones. The implications for respiratory activity and control are discussed.

  8. CLINICAL CO RELATION BETWEEN ARTERIAL VERSUS VENOUS AMMONIA LEVELS IN HEPATIC ENCEPHLOPATHY IN CIRRHOSIS OF LIVER

    Directory of Open Access Journals (Sweden)

    Manjunath

    2014-05-01

    Full Text Available : INTRODUCTION: Hepatic encephalopathy is a reversible neuropsychiatry state that complicates liver disease. Pathogenesis of Hepatic Encephalopathy in chronic liver is function is widely accepted to be due to failure of hepatic clearance of toxins products from gut exact toxin involved remains controversial but ammonia is thought to be an important factor. Ammonia levels help both in diagnosis and serve as a guide in treatment. Diagnosis of Hepatic Encephalopathy can be done based on clinical criteria and the severity of Hepatic Encephalopathy can be graded by West Haven Criteria. This criterion is the simplest grading of Hepatic Encephalopathy based on clinical findings. AIMS AND OBJECTIVES: To correlate between Ammonia levels and clinical severity of Hepatic Encephalopathy in Cirrhosis of liver and correlate between Arterial versus venous ammonia levels with severity of Hepatic Encephalopathy. RESULTS: Male patients had higher incidence than females. Severity of hepatic encephalopathy was graded by West Haven grading. Arterial total ammonia and venous ammonia was correlated with the clinical severity of HE. Of the 50 patients 3 had grade 1, 18 had grade 2, 22 had grade 3 and 7 had grade 4. Arterial and venous ammonia levels co related with severity of HE. The highest level of arterial ammonia was seen in grade 3 and grade 4.It was seen that other lab parameters also increased with severity of HE. But were not significant. Serum albumin was inversely co related with severity of HE. CONCLUSIONS: Arterial total ammonia correlated better with the severity of Hepatic Encephalopathy as compared to venous ammonia levels. Venous total ammonia did not correlate with severity of Hepatic Encephalopathy and with arterial ammonia levels.

  9. Prediction of Left Ventricular Filling Pressure by 3-Dimensional Speckle-Tracking Echocardiography in Patients With Coronary Artery Disease.

    Science.gov (United States)

    Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Zhang, Jin-Ping; Wu, Wei-Chun; Wang, Hao

    2015-10-01

    The purpose of this study was to investigate the diagnostic value of 3-dimensional (3D) speckle-tracking echocardiography for estimating left ventricular filling pressure in patients with coronary artery disease (CAD) and a preserved left ventricular ejection fraction. Altogether, 84 patients with CAD and 30 age- and sex-matched healthy control participants in sinus rhythm were recruited prospectively. All participants underwent conventional and 3D speckle-tracking echocardiography. Global strain values were automatically calculated by 3D speckle-tracking analysis. The left ventricular end-diastolic pressure (LVEDP) was determined invasively by left heart catheterization. Echocardiography and cardiac catheterization were performed within 24 hours. Compared with the controls, patients with CAD showed lower global longitudinal strain, global circumferential strain, global area strain, and global radial strain. Patients with CAD who had an elevated LVEDP had much lower levels of all 4 3D-speckle-tracking echocardiographic variables. Pearson correlation analysis revealed that the LVEDP correlated positively with the early transmitral flow velocity/early diastolic myocardial velocity (E/E') ratio, global longitudinal strain, global circumferential strain, and global area strain. It correlated negatively with global radial strain. Receiver operating characteristic curve analysis revealed that these 3D speckle-tracking echocardiographic indices could effectively predict elevated left ventricular filling pressure (LVEDP >15 mm Hg) in patients with CAD (areas under the curve: global longitudinal strain, 0.78; global radial strain, 0.77; global circumferential strain, 0.75; and global area strain, 0.74). These parameters, however, showed no advantages over the commonly used E/E' ratio (area under the curve, 0.84). Three-dimensional speckle-tracking echocardiography was a practical technique for predicting elevated left ventricular filling pressure, but it might not be

  10. Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study.

    Science.gov (United States)

    Dahl, Michael K; Vistisen, Simon T; Koefoed-Nielsen, Jacob; Larsson, Anders

    2009-01-01

    Fluid responsiveness prediction is difficult in spontaneously breathing patients. Because the swings in intrathoracic pressure are minor during spontaneous breathing, dynamic parameters like pulse pressure variation (PPV) and systolic pressure variation (SPV) are usually small. We hypothesized that during spontaneous breathing, inspiratory and/or expiratory resistors could induce high arterial pressure variations at hypovolemia and low variations at normovolemia and hypervolemia. Furthermore, we hypothesized that SPV and PPV could predict fluid responsiveness under these conditions. Eight prone, anesthetized and spontaneously breathing pigs (20 to 25 kg) were subjected to a sequence of 30% hypovolemia, normovolemia, and 20% and 40% hypervolemia. At each volemic level, the pigs breathed in a randomized order either through an inspiratory and/or an expiratory threshold resistor (7.5 cmH2O) or only through the tracheal tube without any resistor. Hemodynamic and respiratory variables were measured during the breathing modes. Fluid responsiveness was defined as a 15% increase in stroke volume (DeltaSV) following fluid loading. Stroke volume was significantly lower at hypovolemia compared with normovolemia, but no differences were found between normovolemia and 20% or 40% hypervolemia. Compared with breathing through no resistor, SPV was magnified by all resistors at hypovolemia whereas there were no changes at normovolemia and hypervolemia. PPV was magnified by the inspiratory resistor and the combined inspiratory and expiratory resistor. Regression analysis of SPV or PPV versus DeltaSV showed the highest R2 (0.83 for SPV and 0.52 for PPV) when the expiratory resistor was applied. The corresponding sensitivity and specificity for prediction of fluid responsiveness were 100% and 100%, respectively, for SPV and 100% and 81%, respectively, for PPV. Inspiratory and/or expiratory threshold resistors magnified SPV and PPV in spontaneously breathing pigs during hypovolemia

  11. Effect of kefir and low-dose aspirin on arterial blood pressure measurements and renal apoptosis in unhypertensive rats with 4 weeks salt diet.

    Science.gov (United States)

    Kanbak, Güngör; Uzuner, Kubilay; Kuşat Ol, Kevser; Oğlakçı, Ayşegül; Kartkaya, Kazım; Şentürk, Hakan

    2014-01-01

    Abstract We aim to study the effect of low-dose aspirin and kefir on arterial blood pressure measurements and renal apoptosis in unhypertensive rats with 4 weeks salt diet. Forty adult male Sprague-Dawley rats were divided into five groups: control, high-salt (HS) (8.0% NaCl), HS+aspirin (10 mg/kg), HS+kefir (10.0%w/v), HS+aspirin +kefir. We measured sistolic blood pressure (SBP), mean arterial pressure (MAP), diastolic pressure, pulse pressure in the rats. Cathepsin B, L, DNA fragmentation and caspase-3 activities were determined from rat kidney tissues and rats clearance of creatinine calculated. Although HS diet increased significantly SBP, MAP, diastolic pressure, pulse pressure parameters compared the control values. They were not as high as accepted hypertension levels. When compared to HS groups, kefir groups significantly decrease Cathepsin B and DNA fragmentation levels. Caspase levels were elevated slightly in other groups according to control group. While, we also found that creatinine clearance was higher in HS+kefir and HS+low-dose aspirin than HS group. Thus, using low-dose aspirin had been approximately decreased of renal function damage. Kefir decreased renal function damage playing as Angiotensin-converting enzyme inhibitor. But, low-dose aspirin together with kefir worsened rat renal function damage. Cathepsin B might play role both apoptosis and prorenin-processing enzyme. But not caspase pathway may be involved in the present HS diet induced apoptosis. In conclusion, kefir and low-dose aspirin used independently protect renal function and renal damage induced by HS diet in rats.

  12. Levels of Assertiveness and Peer Pressure of Nursing Students

    Directory of Open Access Journals (Sweden)

    Esin Arslan

    2013-01-01

    Full Text Available Background: The research was conducted in order to determine levels of assertiveness and peer pressure of the nursing students.Methodology: This descriptive research has been performed with 154 nursing students in Bozok University, The data were collected with Questionnaire Form, Rathus Assertiveness Inventory and Peer Pressure Scale. We used the data one way Anova, two samples t test, the relationship between several independent variables and scales were evaluated by Pearson correlation technique in order to evaluate the data with normal distribution.Results: It was seen that 69.5% of the students was assertive and mean scores for assertiveness of the male students (19.4±17.9 were higher than that of the female students (29.0±14.1. However, mean scores for peer pressure of the male students (56.6±12.4 were higher than that of the female students (44.0±8.8. It was found out that there was a positive direction middle level significant correlation between mean assertiveness scores and mean peer pressure scores of the studentsConclusion: Although we did not find any significant correlation between mean assertiveness scores and mean peer pressure scores, it was seen that male students were more assertive than female students and male students experienced peer pressure more than female students.

  13. Plasma levels of the arterial wall protein fibulin-1 are associated with carotid-femoral pulse wave velocity

    DEFF Research Database (Denmark)

    Laugesen, Esben; Høyem, Pernille; Christiansen, Jens Sandahl;

    2013-01-01

    -associated extracellular matrix protein, fibulin-1, was recently found in higher concentrations in the arterial wall and in plasma in patients with long duration type 2 diabetes. Furthermore, plasma fibulin-1 independently predicted total mortality and was associated with pulse pressure, an indirect measure of arterial...

  14. Differential impact of blood pressure-lowering drugs on central aortic pressure and clinical outcomes: principal results of the Conduit Artery Function Evaluation (CAFE) study.

    Science.gov (United States)

    Williams, Bryan; Lacy, Peter S; Thom, Simon M; Cruickshank, Kennedy; Stanton, Alice; Collier, David; Hughes, Alun D; Thurston, H; O'Rourke, Michael

    2006-03-07

    Different blood pressure (BP)-lowering drugs could have different effects on central aortic pressures and thus cardiovascular outcome despite similar effects on brachial BP. The Conduit Artery Function Evaluation (CAFE) study, a substudy of the Anglo-Scandinavian Cardiac Outcomes Trial (ASCOT), examined the impact of 2 different BP lowering-regimens (atenolol+/-thiazide-based versus amlodipine+/-perindopril-based therapy) on derived central aortic pressures and hemodynamics. The CAFE study recruited 2199 patients in 5 ASCOT centers. Radial artery applanation tonometry and pulse wave analysis were used to derive central aortic pressures and hemodynamic indexes on repeated visits for up to 4 years. Most patients received combination therapy throughout the study. Despite similar brachial systolic BPs between treatment groups (Delta0.7 mm Hg; 95% CI, -0.4 to 1.7; P=0.2), there were substantial reductions in central aortic pressures with the amlodipine regimen (central aortic systolic BP, Delta4.3 mm Hg; 95% CI, 3.3 to 5.4; PCAFE cohort (unadjusted, P<0.0001; adjusted for baseline variables, P<0.05). BP-lowering drugs can have substantially different effects on central aortic pressures and hemodynamics despite a similar impact on brachial BP. Moreover, central aortic pulse pressure may be a determinant of clinical outcomes, and differences in central aortic pressures may be a potential mechanism to explain the different clinical outcomes between the 2 BP treatment arms in ASCOT.

  15. Pressão arterial entre trabalhadores de curtume Blood pressure among tannery workers

    Directory of Open Access Journals (Sweden)

    Ricardo Cordeiro

    1998-10-01

    Full Text Available INTRODUÇÃO: O grupo das doenças cardiovasculares tem sido apontado como a principal causa de óbito no Brasil desde os anos 70, sendo a hipertensão arterial sistêmica (HAS o fator de risco mais importante para esse grupo. Entre os trabalhadores observa-se correlação negativa entre o status ocupacional e a pressão arterial. Tais fatos ressaltam a importância do conhecimento da distribuição da pressão arterial sistêmica entre os distintos grupos profissionais. Assim, foi realizado estudo para descrever o status pressórico de uma população homogênea e estável de trabalhadores do setor secundário da economia, pouco especializados e que ganham baixos salários, estabelecendo a prevalência da HAS nesse grupo específico, relacionando-a com algumas covariáveis biológicas e socioeconômicas, e comparando-a com a prevalência de HAS em outros grupos profissionais no Brasil. MÉTODO: Foram estudados 73 trabalhadores regularmente empregados em julho de 1993 em um curtume situado no Município de Botucatu, cidade de médio porte da região Centro-Oeste do Estado de São Paulo, os quais foram submetidos a exame antropométrico, aferição de pressão arterial, anamnese e exame clínico. Os resultados foram comparados com os obtidos em estudos semelhantes, controlando-se o confundimento da idade por intermédio de diferentes técnicas. RESULTADOS: A prevalência bruta da HAS encontrada foi de 56,1%, sendo 15,8% a prevalência de hipertensão sistólica isolada. Ambas se associaram ao etilismo e ao tabagismo na população estudada. DISCUSSÃO: A prevalência da hipertensão foi consideravelmente alta e significativamente maior do que a encontrada em outros grupos de trabalhadores estudados no Brasil. Tal achado ressalta a necessidade da continuidade da investigação, objetivando o isolamento dos fatores implicados na elevação pressórica do grupo estudado.INTRODUCTION: Cardiovascular diseases have been shown to be the leading cause of

  16. Ultrasonic level sensors for liquids under high pressure

    Science.gov (United States)

    Zuckerwar, A. J.; Mazel, D. S.; Hodges, D. Y.

    1986-01-01

    An ultrasonic level sensor of novel design continuously measures the level of a liquid subjected to a high pressure (up to about 40 MPa), as is sometimes required for the effective transfer of the liquid. The sensor operates as a composite resonator fabricated from a standard high-pressure plug. A flat-bottom hole is machined into the plug along its center line. An ultrasonic transducer is bonded rigidly to the interior surface of the bottom wall, while the exterior surface is in contact with the liquid. Although the bottom wall is designed to satisfy the pressure code, it is still sufficiently thin to permit ready excitation of the axisymmetric plate modes of vibration. The liquid level is measured by a conventional pulse-echo technique. A prototype sensor was tested successfully in a 2300-l water vessel at pressures up to about 37 MPa. A spectral analysis of the transmitted pulse reveals that the flexural, extensional, thickness-shear, and radial plate modes are excited into vibration, but none of these appears to be significantly affected by the pressurization of the liquid.

  17. Value of systolic pulmonary arterial pressure as a prognostic factor of death in the systemic sclerosis EUSTAR population

    DEFF Research Database (Denmark)

    Hachulla, Eric; Clerson, Pierre; Airò, Paolo

    2015-01-01

    OBJECTIVE: The aim of this study was to assess the prognostic value of systolic pulmonary artery pressure (sPAP) estimated by echocardiography in the multinational European League Against Rheumatism Scleroderma Trial and Research (EUSTAR) cohort. METHODS: Data for patients with echocardiography d...

  18. Finger arterial versus intrabrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects

    NARCIS (Netherlands)

    Jellema, W.T.; Imholz, B.P.M.; Goudoever, J. van; Wesseling, K.H.; Lieshout, J.J. van

    1996-01-01

    1. The aims of this study were to determine the clinical feasibility of continuous, non-invasive Finapres recordings as a replacement for intrabrachial pressure during a 30 min head-up tilt, and the reliability of continuous cardiac output computation by pulse contour analysis from the finger arteri

  19. Effects of sodium and potassium supplementation on blood pressure and arterial stiffness : a fully controlled dietary intervention study

    NARCIS (Netherlands)

    Gijsbers, L.; Dower, J. I.; Mensink, M.; Siebelink, E.; Bakker, S. J. L.; Geleijnse, J. M.

    2015-01-01

    We performed a randomised, placebo-controlled, crossover study to examine the effects of sodium and potassium supplementation on blood pressure (BP) and arterial stiffness in untreated (pre) hypertensive individuals. During the study, subjects were on a fully controlled diet that was relatively low

  20. [Anesthesia management of geriatric patients with arterial pressure-based cardiac output monitoring FloTrac sensor for emergency surgery].

    Science.gov (United States)

    Yamamoto, Shunsuke; Goto, Koji; Yasuda, Norihisa; Kusaka, Junya; Hidaka, Seigo; Miyakawa, Hiroshi; Noguchi, Takayuki

    2009-06-01

    In cases of emergency surgery for geriatric patients, immediate anesthesia induction and careful intraoperative management is necessary without sufficient preoperative information. We report anesthesia management of a 96-year and a 90-year old patients with FloTrac sensor which is an arterial pressure-based cardiac output monitoring device and is able to manage critical patients effectively and safely during anesthesia.

  1. Early detection and treatment of myocardial ischaemia after operation using continual ambulatory arterial pressure monitoring and ECG ST segment analysis.

    Science.gov (United States)

    Edwards, N D; Troy, G; Yeo, W; Jackson, P; Reilly, C S

    1995-10-01

    We report a case in which the use of continual ambulatory arterial pressure monitoring and ECG ST-segment analysis allowed early detection and treatment of myocardial ischaemia in the postoperative period. We believe that this case illustrates the potential value of ambulatory monitoring in the early postoperative period in high-risk patients.

  2. Ambulatory instrument for monitoring indirect beat-to-beat blood pressure in superficial temporal artery using volume-compensation method.

    Science.gov (United States)

    Tanaka, S; Yamakoshi, K

    1996-11-01

    A portable instrument, based on a volume-compensation technique, is designed for ambulatory monitoring of indirect beat-to-beat blood pressure (BP) in the superficial temporal artery. The instrument consists of a small disc-type cuff and a portable unit carried by the subject. Several components are integrated in the cuff for applying counter-pressure to the artery, i.e. a reflectance-type photo-plethysmographic sensor for arterial volume detection, a pressure sensor for cuff pressure Pc measurement and a nozzle flapper-type- electro-pneumatic convertor for controlling Pc. The portable unit includes volume servo control circuitry and a microprocessor-based signal-processing and recording unit. This automatically performs all the necessary measurement procedures and stores into a memory IC element the processed systolic, mean and diastolic blood pressure data, together with pulse intervals on a beat-to-beat basis from the servo-controlled Pc (indirectly measured BP waveform). With this instrument, momentary changes in BP during ambulatory situations such as bicycle ergometer exercise and daily activities including motorway driving are successfully recorded. From the results of simultaneous measurement of the subject's posture changes, the effect of posture change on blood pressure, e.g. baroreceptor-cardiac reflex, is also clearly demonstrated.

  3. Association of vitamin D status with arterial blood pressure and hypertension risk: a mendelian randomisation study

    Science.gov (United States)

    Vimaleswaran, Karani S; Cavadino, Alana; Berry, Diane J; Jorde, Rolf; Dieffenbach, Aida Karina; Lu, Chen; Alves, Alexessander Couto; Heerspink, Hiddo J Lambers; Tikkanen, Emmi; Eriksson, Joel; Wong, Andrew; Mangino, Massimo; Jablonski, Kathleen A; Nolte, Ilja M; Houston, Denise K; Ahluwalia, Tarunveer Singh; van der Most, Peter J; Pasko, Dorota; Zgaga, Lina; Thiering, Elisabeth; Vitart, Veronique; Fraser, Ross M; Huffman, Jennifer E; de Boer, Rudolf A; Schöttker, Ben; Saum, Kai-Uwe; McCarthy, Mark I; Dupuis, Josée; Herzig, Karl-Heinz; Sebert, Sylvain; Pouta, Anneli; Laitinen, Jaana; Kleber, Marcus E; Navis, Gerjan; Lorentzon, Mattias; Jameson, Karen; Arden, Nigel; Cooper, Jackie A; Acharya, Jayshree; Hardy, Rebecca; Raitakari, Olli; Ripatti, Samuli; Billings, Liana K; Lahti, Jari; Osmond, Clive; Penninx, Brenda W; Rejnmark, Lars; Lohman, Kurt K; Paternoster, Lavinia; Stolk, Ronald P; Hernandez, Dena G; Byberg, Liisa; Hagström, Emil; Melhus, Håkan; Ingelsson, Erik; Mellström, Dan; Ljunggren, Östen; Tzoulaki, Ioanna; McLachlan, Stela; Theodoratou, Evropi; Tiesler, Carla M T; Jula, Antti; Navarro, Pau; Wright, Alan F; Polasek, Ozren; Hayward, Caroline; Wilson, James F; Rudan, Igor; Salomaa, Veikko; Heinrich, Joachim; Campbell, Harry; Price, Jacqueline F; Karlsson, Magnus; Lind, Lars; Michaëlsson, Karl; Bandinelli, Stefania; Frayling, Timothy M; Hartman, Catharina A; Sørensen, Thorkild I A; Kritchevsky, Stephen B; Langdahl, Bente Lomholt; Eriksson, Johan G; Florez, Jose C; Spector, Tim D; Lehtimäki, Terho; Kuh, Diana; Humphries, Steve E; Cooper, Cyrus; Ohlsson, Claes; März, Winfried; de Borst, Martin H; Kumari, Meena; Kivimaki, Mika; Wang, Thomas J; Power, Chris; Brenner, Hermann; Grimnes, Guri; van der Harst, Pim; Snieder, Harold; Hingorani, Aroon D; Pilz, Stefan; Whittaker, John C; Järvelin, Marjo-Riitta; Hyppönen, Elina

    2015-01-01

    Summary Background Low plasma 25-hydroxyvitamin D (25[OH]D) concentration is associated with high arterial blood pressure and hypertension risk, but whether this association is causal is unknown. We used a mendelian randomisation approach to test whether 25(OH)D concentration is causally associated with blood pressure and hypertension risk. Methods In this mendelian randomisation study, we generated an allele score (25[OH]D synthesis score) based on variants of genes that affect 25(OH)D synthesis or substrate availability (CYP2R1 and DHCR7), which we used as a proxy for 25(OH)D concentration. We meta-analysed data for up to 108 173 individuals from 35 studies in the D-CarDia collaboration to investigate associations between the allele score and blood pressure measurements. We complemented these analyses with previously published summary statistics from the International Consortium on Blood Pressure (ICBP), the Cohorts for Heart and Aging Research in Genomic Epidemiology (CHARGE) consortium, and the Global Blood Pressure Genetics (Global BPGen) consortium. Findings In phenotypic analyses (up to n=49 363), increased 25(OH)D concentration was associated with decreased systolic blood pressure (β per 10% increase, −0·12 mm Hg, 95% CI −0·20 to −0·04; p=0·003) and reduced odds of hypertension (odds ratio [OR] 0·98, 95% CI 0·97−0·99; p=0·0003), but not with decreased diastolic blood pressure (β per 10% increase, −0·02 mm Hg, −0·08 to 0·03; p=0·37). In meta-analyses in which we combined data from D-CarDia and the ICBP (n=146 581, after exclusion of overlapping studies), each 25(OH)D-increasing allele of the synthesis score was associated with a change of −0·10 mm Hg in systolic blood pressure (−0·21 to −0·0001; p=0·0498) and a change of −0·08 mm Hg in diastolic blood pressure (−0·15 to −0·02; p=0·01). When D-CarDia and consortia data for hypertension were meta-analysed together (n=142 255), the synthesis score was associated

  4. Pulmonary Artery Wedge Pressure Relative to Exercise Work Rate in Older Men and Women.

    Science.gov (United States)

    Esfandiari, Sam; Wright, Stephen P; Goodman, Jack M; Sasson, Zion; Mak, Susanna

    2017-07-01

    An augmented pulmonary artery wedge pressure (PAWP) response may explain exercise intolerance in some humans. However, routine use of exercise hemodynamic testing is limited by a lack of data from normal older men and women. Our objective was to evaluate the exercise PAWP response and the potential for sexual dimorphism in healthy, nondyspneic older adults. Thirty-six healthy volunteers (18 men [54 ± 7 yr] and 18 women [58 ± 6 yr]) were studied at rest (control) and during two stages of semi-upright cycle ergometry, at heart rates of 100 bpm (light exercise) and 120 bpm (moderate exercise). Right heart catheterization was performed to measure pulmonary pressures. The PAWP response to exercise was assessed in context of exercise work rate and body size. At control, PAWP was similar between men and women. Work rates were significantly smaller in women at comparable HR (P relative to the increase in cardiac output did not exceed 2 mm Hg·L·min in any volunteer at moderate exercise. The similar rise in the PAWP response to submaximal exercise occurs despite lower work rate in healthy older women compared with men, even when adjusted for smaller body size. It is important to consider sex in the development of normal reference ranges for exercise hemodynamic testing.

  5. Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors

    Directory of Open Access Journals (Sweden)

    Deirdre M Mooney

    2015-10-01

    Full Text Available Heart failure (HF is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension.

  6. Cardiovascular system identification: Simulation study using arterial and central venous pressures.

    Science.gov (United States)

    Karamolegkos, Nikolaos; Vicario, Francesco; Chbat, Nicolas W

    2015-08-01

    The paper presents a study of the identifiability of a lumped model of the cardiovascular system. The significance of this work from the existing literature is in the potential advantage of using both arterial and central venous (CVP) pressures, two signals that are frequently monitored in the critical care unit. The analysis is done on the system's state-space representation via control theory and system identification techniques. Non-parametric state-space identification is preferred over other identification techniques as it optimally assesses the order of a model, which best describes the input-output data, without any prior knowledge about the system. In particular, a recent system identification algorithm, namely Observer Kalman Filter Identification with Deterministic Projection, is used to identify a simplified version of an existing cardiopulmonary model. The outcome of the study highlights the following two facts. In the deterministic (noiseless) case, the theoretical indicators report that the model is fully identifiable, whereas the stochastic case reveals the difficulty in determining the complete system's dynamics. This suggests that even with the use of CVP as an additional pressure signal, the identification of a more detailed (high order) model of the circulatory system remains a challenging task.

  7. Hematocrit and mean arterial blood pressure in pre- and postmenopause women

    Directory of Open Access Journals (Sweden)

    Beatriz Y Salazar Vázquez

    2009-05-01

    Full Text Available Beatriz Y Salazar Vázquez1,2, Miguel A Salazar Vázquez3,4, Marcos Intaglietta2, Ulf de Faire5, Bengt Fagrell6, Pedro Cabrales21Facultad de Medicina, 3Department of Physical Chemistry, Universidad Juárez del estado de Durango, Durango, México; 2Department of Bioengineering, University of California, San Diego, La Jolla, CA, USA; 4Department of Pediatrics, Instituto Mexicano del Seguro Social, Durango, México; 5Division of Cardiovascular Epidemiology, Institute of Environmental Medicine, Department of Cardiology, Karolinska Institutet, Solna, Stockholm, Sweden; 6Department of Medicine, Karolinska Institutet at Karolinska Hospital, Solna, Stockholm, SwedenAbstract: The relationship between mean arterial blood pressure (MAP and hematocrit (Hct was studied in pre- and postmenopause women in the city of Durango, Mexico. Premenopause women show a negative trend between parameters that is not statistically significant. MAP and Hct are directly related in postmenopause women (p < 0.01. It is proposed that that this MAP/Hct relationship is in part due to differences in endothelial function where menopause decreases the capacity of the endothelium to respond to increased blood viscosity and shears stress, leading to the increased production of vasodilator mediators to compensate for changes in blood viscosity due to changes in Hct. Comparison with a large group of postmenopause women in the city of Stockholm showed identical trends.Keywords: menopause, endothelial dysfunction, blood viscosity, blood pressure, hematocrit

  8. Arterial Catheterization

    Science.gov (United States)

    ... way of keeping the blood pressure up. The arterial catheter allows accurate, second-to-second measurement of the blood pressure; repeated meas- urement is called monitoring. ■ High blood pressure (hypertension)— In some sit- uations, ...

  9. Sleep Bruxism Is Associated with a Rise in Arterial Blood Pressure

    Science.gov (United States)

    Nashed, Angela; Lanfranchi, Paola; Rompré, Pierre; Carra, Maria Clotilde; Mayer, Pierre; Colombo, Roberto; Huynh, Nelly; Lavigne, Gilles

    2012-01-01

    Study Objectives: Sleep bruxism (SB) is a movement disorder identified by grinding of teeth and rhythmic masticatory muscle activity (RMMA). RMMA is associated with body movements and cortical arousals. Increases in autonomic sympathetic activities that characterize sleep cortical arousal precede RMMA/SB. Based on these findings, this study examined whether RMMA/SB episodes are also associated with significant changes in arterial blood pressure (BP). Design: Participants underwent 3 nights of full polysomnography that included noninvasive beat-to-beat BP recording. Single RMMA/SB episodes and arousal episodes were analyzed in stage 2 sleep and categorized as: (i) RMMA/SB + arousal; (ii) RMMA/SB + body movement; (iii) RMMA/SB + arousal + body movement; or (iv) arousal alone. Sleep and RMMA/SB data were compared to a Non SB group. RMMA/SB clusters (RMMA/SB episodes ≤ 30 sec apart) were also analyzed. Setting: Sleep Laboratory at l'Hôpital du Sacré-Coeur de Montréal. Participants: Ten young, healthy participants with SB (mean age = 26 ± 1.8 years) and 9 without SB (mean age = 29 ± 1.2 years). Interventions: N/A Measurements and Results: BP increased with all RMMA/SB and arousal episodes (P ≤ 0.05). The average maximum BP surges (systolic/diastolic ± SE mm Hg) were: 25.6 ± 3.3/12.6 ± 2.0 for RMMA/SB + arousal; 30.1 ± 1.7/19.1 ± 1.9 for RMMA/SB + body movement; 26.0 ± 2.8/15.1 ± 2.0 for RMMA/SB + arousal + body movement; 19.4 ± 2.3/8.9 ± 1.2 for arousal alone; and for RMMA/SB clusters: Episode: 1: 26.2 ± 8.7/16.4 ± 5.7; Episode 2: 21.1 ± 7.9/12.6 ± 6.4. Conclusion: Rhythmic masticatory muscle activity/sleep bruxism (RMMA/SB) is associated with blood pressure fluctuations during sleep. Arousals and body movements often occur with RMMA/SB and can impact the magnitude of this BP surge. Citation: Nashed A; Lanfranchi P; Rompré P; Carra MC; Mayer P; Colombo R; Huynh N; Lavigne G. Sleep bruxism is associated with a rise in arterial blood pressure. SLEEP

  10. Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device.

    Science.gov (United States)

    Saugel, B; Meidert, A S; Hapfelmeier, A; Eyer, F; Schmid, R M; Huber, W

    2013-08-01

    The T-Line TL-200pro (TL-200pro) device (Tensys Medical, Inc., San Diego, CA, USA), based on radial artery tonometry, provides an arterial pressure (AP) waveform and beat-to-beat values of systolic arterial pressure (SAP), mean arterial pressure (MAP), and diastolic arterial pressure (DAP). The aim of the study was to evaluate this non-invasive technique for continuous AP monitoring in medical intensive care unit (ICU) patients. Arterial pressure measurements obtained using the TL-200pro technology were compared using Bland-Altman analysis with values measured directly from a femoral arterial catheter in 34 ICU patients. Arterial pressure values were analysed and compared in 4502 averaged 10-beat epochs. A bias of +0.72 mm Hg (95% limits of agreement -9.37 to +10.82 mm Hg) was observed for MAP. For SAP and DAP, there was a mean difference of -1.39 mm Hg (95% limits of agreement -18.74 to +15.96 mm Hg) and +4.36 mm Hg (95% limits of agreement -8.66 to +17.38 mm Hg), respectively. The percentage error for MAP, SAP, and DAP was 12%, 14%, and 21%, respectively. Arterial pressure measurement based on radial artery tonometry using the TL-200pro technology is feasible in medical ICU patients. The TL-200pro system is capable of providing MAP values with high accuracy (low mean difference) and precision (narrow limits of agreement) compared with MAP measured invasively using a femoral arterial catheter. The TL-200pro technology is promising for the measurement of SAP and DAP but further development is necessary to improve accuracy and precision.

  11. Low blood pressure and antihypertensive treatment are independently associated with physical and mental health status in patients with arterial disease: the SMART study.

    Science.gov (United States)

    Muller, M; Jochemsen, H M; Visseren, F L J; Grool, A M; Launer, L J; van der Graaf, Y; Geerlings, M I

    2013-09-01

    To investigate the independent effects of antihypertensive treatment and blood pressure (BP) levels on physical and mental health status in patients with arterial disease. Cross-sectional analyses were conducted within the single-centre Secondary Manifestations of ARTerial disease (SMART) study, in a hospital care setting. A total of 5877 patients (mean age 57 years) with symptomatic and asymptomatic arterial disease underwent standardized vascular screening. The primary outcome was self-rated physical and mental health assessed using the 36-item short-form health survey. In the total population, antihypertensive drug use and increased intensity of antihypertensive treatment were associated with poorer health status independent of important confounders including BP levels; adjusted mean differences [95% confidence interval (CI)] in physical and mental health between n = 0 and n ≥ 3 antihypertensives were -1.2 (-2.1; -0.3) and -3.5 (-4.4; -2.6), respectively. Furthermore, both lower systolic and lower diastolic BP levels were related to poorer physical and mental health status independent of antihypertensive treatment. Mean differences (95% CI) in physical and mental health status per SD decrease in systolic BP were -0.56 (-0.84; -0.27) and -0.32 (-0.61; -0.03) and per SD decrease in diastolic BP were -0.50 (-0.78; -0.23) and -0.08 (-0.36; 0.20), respectively. The association between low BP and poor health status was particularly present in patients with coronary artery disease. In a population of patients with asymptomatic and symptomatic arterial disease, antihypertensive treatment and lower BP levels are independently associated with poorer self-rated physical and mental health. These findings suggest that different underlying mechanisms may explain these independent associations. © 2013 The Association for the Publication of the Journal of Internal Medicine.

  12. Elevated circulating leptin levels in arterial hypertension: relationship to arteriovenous overflow and extraction of leptin

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Holst, J J; Moller, S

    2000-01-01

    Leptin, a peptide hormone produced mainly in fat cells, appears to be important for the regulation of metabolism, insulin secretion/sensitivity and body weight. Recently, elevated plasma leptin levels have been reported in patients with arterial hypertension. Because a change in circulating leptin...... concentrations in such patients could be caused by altered rates of production or disposal, or both, the aim of the present study was to identify regions of leptin overflow into the bloodstream and of leptin extraction. Patients with arterial hypertension (n=12) and normotensive controls (n=20) were studied...... during catheterization with elective blood sampling from different vascular beds (artery, and renal, hepatic, iliac and cubital veins). Plasma leptin was determined by a radioimmunoassay. Patients with hypertension had significantly elevated levels of circulating leptin (12.8 ng/l, compared with 4.1 ng...

  13. Short-term effects of nitrate-rich green leafy vegetables on blood pressure and arterial stiffness in individuals with high-normal blood pressure.

    Science.gov (United States)

    Bondonno, Catherine P; Liu, Alex H; Croft, Kevin D; Ward, Natalie C; Yang, Xingbin; Considine, Michael J; Puddey, Ian B; Woodman, Richard J; Hodgson, Jonathan M

    2014-12-01

    Evidence for a beneficial effect of dietary nitrate, through the nitrate-nitrite-NO pathway, on measures of cardiovascular function in healthy individuals is accumulating. It is less clear whether increased dietary nitrate intake from green leafy vegetables would have similar beneficial vascular effects in those at increased risk of developing hypertension. Our aim was to assess the effects of short-term regular consumption of increased nitrate from green leafy vegetables on blood pressure and arterial stiffness in individuals with high-normal blood pressure. Thirty-eight men and women ages 30-70 years with systolic blood pressure 120 to 139 mm Hg were recruited to a randomized controlled crossover trial. The effects of a 7-day high-nitrate diet intervention (increased nitrate intake by at least 300 mg/day from green leafy vegetables) were compared to a 7-day low-nitrate diet intervention. Outcome measures included pre- and postintervention salivary and plasma nitrate and nitrite concentrations; ambulatory, home, and office blood pressure; augmentation index; and carotid-femoral pulse wave velocity. The high-nitrate diet intervention resulted in at least a fourfold increase in salivary and plasma nitrate and nitrite (Pblood pressure and arterial stiffness were not different between the high-nitrate diet and the low-nitrate diet. Increasing dietary nitrate intake in those with high-normal blood pressure and at increased risk of hypertension may not be an effective short-term strategy to lower blood pressure.

  14. Comparison of the role of endothelin, vasopressin and angiotensin in arterial pressure regulation during sevoflurane anaesthesia in dogs.

    Science.gov (United States)

    Picker, O; Schwarte, L A; Roth, H J; Greve, J; Scheeren, T W L

    2004-01-01

    In this study we aimed to clarify the role of endothelin in arterial pressure regulation during anaesthesia with increasing concentrations of sevoflurane (1-3 MAC) and compare it with those of vasopressin and angiotensin. After an awake control period, on different days, six dogs underwent each of the following four interventions: sevoflurane anaesthesia alone (1-3 MAC), sevoflurane after block of either endothelin receptors using tezosentan (3 mg kg(-1) followed by 3 mg kg(-1) h(-1)), vasopressin V(1a) receptors using [d(CH(2))(5)Tyr(Me(2))]AVP (40 micro g kg(--1)) or angiotensin receptors using losartan (6 mg kg(-1) h(-1)). Plasma concentrations of endothelin, big endothelin, vasopressin and renin were measured. Effects of sevoflurane in the presence and absence of the respective receptor block were analysed and compared using analysis of variance for repeated measures (ANOVA followed by Fisher's PLSD (protected least significant difference) (PMAC, this decrease was greatest during angiotensin receptor block (mean (SEM), -41 (3) mm Hg), intermediate during vasopressin and endothelin receptor block (-31 (4) and -30 (2) mm Hg respectively), and least during sevoflurane alone (-24 (3) mm Hg). The course of systemic vascular resistance mirrored the course of arterial pressure, while cardiac output did not differ between groups. Plasma concentrations of endothelin, big endothelin and renin did not change during any intervention, whereas vasopressin concentration increased from approximately 0.5 to 40 ng litre(-1) at 3 MAC as arterial pressure decreased in all groups. At 1 MAC, angiotensin attenuated the decrease in arterial pressure during sevoflurane anaesthesia more than endothelin and vasopressin. However, at higher MAC only vasopressin was specifically activated to partly compensate for the arterial pressure decrease.

  15. Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients.

    Science.gov (United States)

    Hohn, A; Defosse, J M; Becker, S; Steffen, C; Wappler, F; Sakka, S G

    2013-08-01

    In this study, we tested the reliability of a non-invasive finger-cuff-based continuous arterial blood pressure monitoring device (Nexfin, BMEYE, Amsterdam, NL) in critically ill surgical patients. Invasive intra-arterial and non-invasive arterial pressure measurements from 25 patients during a 4-h period were compared at five time points. Correlation and linear regression analysis were used and mean bias, precision [sd of bias] and limits of agreement (LOA) [bias (2.0 sd)] were calculated using the Bland-Altman method. Eight data pairs were excluded because of error message from the non-invasive technique, and thus a total of 117 data pairs were analysed. Overall, correlation between mean arterial pressure (MAP) was r(2)=0.50. Bias, precision, and LOA between invasive and non-invasive MAP were 6 (12) and -18 to +30 mm Hg. In patients requiring norepinephrine (83 data pairs), correlation was r(2)=0.28 and bias, precision, and LOA were 6 (13) and -20 to +32 mm Hg, whereas in patients not receiving norepinephrine (34 data pairs) r(2) was 0.80 and mean bias, precision, and LOA were 6 (11) and -16 to +28 mm Hg. In patients with peripheral oedema (49 data pairs), r(2) was 0.40 and mean bias, precision and LOA were 7 (15) and -23 to +37 mm Hg. In patients without oedema (64 data pairs), r(2) was 0.66 and mean bias, precision, and LOA were 5 (9) and -13 to +23 mm Hg. Non-invasive blood pressure monitoring with Nexfin does not seem to be sufficiently accurate to replace intra-arterial invasive blood pressure measurements in critically ill patients.

  16. Low arterial pressure on admission as a predictor of mortality in operated patients with type A aortic dissection

    Directory of Open Access Journals (Sweden)

    Pavlović Katica

    2011-01-01

    Full Text Available Background/Aim. Hypertension is a known predictor of proximal aortic dissection, but it is not commonly present in these patients on presentation. The associations between ascending aorta with left ventricular hypertrophy, cardiovascular risk factors and coronary atherosclerosis, and outcome of these patients are not fully elucidated. Methods. This retrospective study included 55 consecutive patients with acute type A aortic dissection treated surgically in our institution during the last 2 years. The diagnosis was based on imaging studies. Diameter of ascending aorta was measured with echocardiography. Results. The mean age of the patients was 55.4 ± 12.19 years, and 72.7% were men. A history of arterial hypertension was present in 76.4% of the patients. Maximal ascending aorta diameter was 4.09 ± 0.59 cm, while patients with frank aneurysm accounted for 5.5%. Systolic blood pressure on admission was < 150 mmHg in 58.2% of the patients. Diastolic blood pressure on admission was < 90 mmHg in 54.5% of the patients. Mean arterial pressure on admission was 104.9 ± 24.6 mmHg. No correlations were demonstrated between maximal ascending aorta diameter and diameter of the left ventricular wall, any obtained risk factor and with coronary artery atherosclerosis (p > 0.05. After six months 11 (20% patients died, while intrahospital mortality was 72%. According to logistic regression analysis which included traditional risk factors, echo parameters, coronary artery disease and logistic euro scor, mean arterial blood pressure was the independent predictor of a six-month mortality [RR 0.956; CI (0.918-0.994 ; p = 0.024]. Conclusion. In our population the acute type A aortic dissection occurred rarely in the setting of frank ascending aortic aneurysms > 5.0 cm. The majority of patients had a history of arterial hypertension. A history of arterial hypertension was not associated with maximal ascending aorta diameter. Mean arterial blood pressure was the

  17. Arterial blood pressure and renal sodium excretion in dopamine D3 receptor knockout mice.

    Science.gov (United States)

    Staudacher, Torsten; Pech, Bärbel; Tappe, Michael; Gross, Gerhard; Mühlbauer, Bernd; Luippold, Gerd

    2007-01-01

    Alterations in the dopaminergic system may contribute to the development of hypertension. Recently, it has been reported that pentobarbital-anesthetized mice with deficient dopamine D(3) receptors showed renin-dependent elevation in blood pressure. In a series of experiments, we evaluated the contribution of the dopamine D(3) receptor to the renal sodium excretion and arterial blood pressure behavior in conscious as well as anesthetized dopamine D(3) receptor knockout (-/-) mice. The blood pressure measuring study was designed as a cross-over trial to investigate the influence of different sodium loads. The animals were fed a normal salt diet (0.6% NaCl, NS) for 1 week and afterwards a low (0.2% NaCl, LS) or a high salt diet (4.6% NaCl, HS) for 2 weeks. After the third week, the animals were switched to the corresponding protocol. Systolic blood pressure in conscious (-/-) mice measured by tail-cuff plethysmography was not different from that of wild-type (+/+) animals, irrespective of the time course or the salt diet. In another experiment, challenge of an acute sodium loading per gavage in conscious D(3) receptor (-/-) and (+/+) animals on HS or NS diet did not show significant differences in renal sodium excretion between the two genotypes. Additionally, animals were fed an NS diet for 1 week and an HS diet for another week. As expected, sodium excretion significantly increased after the change from the NS to the HS diet. A slightly lower urinary sodium excretion was observed when comparing D(3) receptor (-/-) mice to their corresponding (+/+) mice, both on an HS diet. Clearance experiments with anesthetized D(3) receptor (-/-) and (+/+) mice were performed to investigate the renal sodium excretion capacity, when exposed to a moderate volume expansion (VE). Urinary sodium excretion increased in response to the VE; however, no difference were observed between the two genotypes. Taking these results together, we conclude that in the present animal model renal

  18. Long-term pressure monitoring with arterial applanation tonometry: a non-invasive alternative during clinical intervention?

    Science.gov (United States)

    Matthys, Koen S; Kalmar, Alain F; Struys, Michel M R F; Mortier, Eric P; Avolio, Alberto P; Segers, Patrick; Verdonck, Pascal R

    2008-01-01

    Arterial tonometry is a non-invasive technique for continuous registration of arterial pressure waveforms. This study aims to assess tonometric blood pressure recording (TBP) as an alternative for invasive long-term bedside monitoring. A prospective study was set up where patients undergoing neurosurgical intervention were subjected to both invasive (IBP) and non-invasive (TBP) blood pressure monitoring during the entire procedure. A single-element tonometric pressure transducer was used to better investigate different inherent error sources of TBP measurement. A total of 5.7 hours of combined IBP and TBP were recorded from three patients. Although TBP performed fairly well as an alternative for IBP in steady state scenarios and some short-term variations, it could not detect relevant long-term pressure variations at all times. These findings are discussed in comparison to existing work. Physiological alterations at the site of TBP measurement are highlighted as a potentially important source of artifacts. It is concluded that at this point arterial tonometry remains not enough understood for long-term use during a delicate operative procedure. Physiological changes at the TBP measurement site deserve further investigation before tonometry technology is to be considered as an non-invasive alternative for long-term clinical monitoring.

  19. Noninvasive assessment of cardiac output from arterial pressure profiles during exercise.

    Science.gov (United States)

    Antonutto, G; Girardis, M; Tuniz, D; di Prampero, P E

    1995-01-01

    The stroke volume of the left ventricle (SV) was assessed in nine young men (mean age 22.2, ranging from 20 to 25 years) during cycle ergometer upright exercise at exercise intensities from 60 to 150 W (about 20% to 80% of individual maximal aerobic power). The SV was calculated from noninvasive tracings of the arterial blood pressure, determined from photoplethysmograph records and compared to the SV determined simultaneously by pulsed Doppler echocardiography (PDE). Given the relationship SV = As.Z-1 in which A(s) is the area underneath the systolic pressure profile (in millimetres of mercury and second), and Z (in millimetres of mercury and second per millilitre) is the apparent hydraulic impedance of the circulatory system, a prerequisite for the assessment of SV from the photoplethysmograph tracings is a knowledge of Z. The experimental value of Z (hereafter defined Z*) was calculated by dividing A(s) (from the finger photoplethysmograph) by SV as obtained by PDE. When the whole group of subjects was considered, Z* was not greatly affected by the exercise intensity: it amounted to 0.089 (SD 0.028; n = 36). The Z was also estimated independently of any parameter other than heart rate (HR), mean (MAP) and pulse (PP) arterial blood pressure obtained from the photoplethysmograph. A computerized statistical method allowed us to interpolate the experimental values of Z*, HR, PP and MAP by the equation Zm = a.(b + c.HR + d.PP + e.MAP)-1, thus obtaining the coefficients a to e. The mean percentage error between Zm (calculated from the coefficients obtained and Z* was 21.8 (SD 14.3)%. However, it was observed that, in a given subject, Z* was significantly affected by the exercise intensity. Therefore, to improve the estimate of Z a second algorithm was developed to update the experimental value of Z determined initially at rest (Zin). This updated value (Zcor) of Z was calculated as Zcor = Zin. [(f/(i + g.(HR/HRin) + h.(PP/PPin) + 1.(MAP/MAPin)], where HRin, PPin

  20. System for water level measurement based on pressure transducer

    Science.gov (United States)

    <