WorldWideScience

Sample records for arterial input function

  1. Feasibility study of the non-invasive estimation of the β+ arterial input function for human PET imaging

    International Nuclear Information System (INIS)

    Hubert, X.

    2009-12-01

    This work deals with the estimation of the concentration of molecules in arterial blood which are labelled with positron-emitting radioelements. This concentration is called 'β + arterial input function'. This concentration has to be estimated for a large number of pharmacokinetic analyses. Nowadays it is measured through series of arterial sampling, which is an accurate method but requiring a stringent protocol. Complications might occur during arterial blood sampling because this method is invasive (hematomas, nosocomial infections). The objective of this work is to overcome this risk through a non-invasive estimation of β + input function with an external detector and a collimator. This allows the reconstruction of blood vessels and thus the discrimination of arterial signal from signals in other tissues. Collimators in medical imaging are not adapted to estimate β + input function because their sensitivity is very low. During this work, they are replaced by coded-aperture collimators, originally developed for astronomy. New methods where coded apertures are used with statistical reconstruction algorithms are presented. Techniques for analytical ray-tracing and for the acceleration of reconstructions are proposed. A new method which decomposes reconstructions on temporal sets and on spatial sets is also developed to efficiently estimate arterial input function from series of temporal acquisitions. This work demonstrates that the trade-off between sensitivity and spatial resolution in PET can be improved thanks to coded aperture collimators and statistical reconstruction algorithm; it also provides new tools to implement such improvements. (author)

  2. Estimation of an image derived input function with MR-defined carotid arteries in FDG-PET human studies using a novel partial volume correction method

    DEFF Research Database (Denmark)

    Sari, Hasan; Erlandsson, Kjell; Law, Ian

    2017-01-01

    Kinetic analysis of18F-fluorodeoxyglucose positron emission tomography data requires an accurate knowledge the arterial input function. The gold standard method to measure the arterial input function requires collection of arterial blood samples and is an invasive method. Measuring an image deriv...... input function (p > 0.12 for grey matter and white matter). Hence, the presented image derived input function extraction method can be a practical alternative to noninvasively analyze dynamic18F-fluorodeoxyglucose data without the need for blood sampling....

  3. The effect of blood inflow and B(1)-field inhomogeneity on measurement of the arterial input function in axial 3D spoiled gradient echo dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Roberts, Caleb; Little, Ross; Watson, Yvonne; Zhao, Sha; Buckley, David L; Parker, Geoff J M

    2011-01-01

    A major potential confound in axial 3D dynamic contrast-enhanced magnetic resonance imaging studies is the blood inflow effect; therefore, the choice of slice location for arterial input function measurement within the imaging volume must be considered carefully. The objective of this study was to use computer simulations, flow phantom, and in vivo studies to describe and understand the effect of blood inflow on the measurement of the arterial input function. All experiments were done at 1.5 T using a typical 3D dynamic contrast-enhanced magnetic resonance imaging sequence, and arterial input functions were extracted for each slice in the imaging volume. We simulated a set of arterial input functions based on the same imaging parameters and accounted for blood inflow and radiofrequency field inhomogeneities. Measured arterial input functions along the vessel length from both in vivo and the flow phantom agreed with simulated arterial input functions and show large overestimations in the arterial input function in the first 30 mm of the vessel, whereas arterial input functions measured more centrally achieve accurate contrast agent concentrations. Use of inflow-affected arterial input functions in tracer kinetic modeling shows potential errors of up to 80% in tissue microvascular parameters. These errors emphasize the importance of careful placement of the arterial input function definition location to avoid the effects of blood inflow. © 2010 Wiley-Liss, Inc.

  4. Dynamic Contrast-Enhanced Perfusion MRI of High Grade Brain Gliomas Obtained with Arterial or Venous Waveform Input Function.

    Science.gov (United States)

    Filice, Silvano; Crisi, Girolamo

    2016-01-01

    The aim of this study was to evaluate the differences in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) perfusion estimates of high-grade brain gliomas (HGG) due to the use of an input function (IF) obtained respectively from arterial (AIF) and venous (VIF) approaches by two different commercially available software applications. This prospective study includes 20 patients with pathologically confirmed diagnosis of high-grade gliomas. The data source was processed by using two DCE dedicated commercial packages, both based on the extended Toft model, but the first customized to obtain input function from arterial measurement and the second from sagittal sinus sampling. The quantitative parametric perfusion maps estimated from the two software packages were compared by means of a region of interest (ROI) analysis. The resulting input functions from venous and arterial data were also compared. No significant difference has been found between the perfusion parameters obtained with the two different software packages (P-value < .05). The comparison of the VIFs and AIFs obtained by the two packages showed no statistical differences. Direct comparison of DCE-MRI measurements with IF generated by means of arterial or venous waveform led to no statistical difference in quantitative metrics for evaluating HGG. However, additional research involving DCE-MRI acquisition protocols and post-processing would be beneficial to further substantiate the effectiveness of venous approach as the IF method compared with arterial-based IF measurement. Copyright © 2015 by the American Society of Neuroimaging.

  5. Semi-parametric arterial input functions for quantitative dynamic contrast enhanced magnetic resonance imaging in mice

    Czech Academy of Sciences Publication Activity Database

    Taxt, T.; Reed, R. K.; Pavlin, T.; Rygh, C. B.; Andersen, E.; Jiřík, Radovan

    2018-01-01

    Roč. 46, FEB (2018), s. 10-20 ISSN 0730-725X R&D Projects: GA ČR GA17-13830S; GA MŠk(CZ) LO1212 Institutional support: RVO:68081731 Keywords : DCE-MRI * blind deconvolution * arterial input function Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 2.225, year: 2016

  6. A curve-fitting approach to estimate the arterial plasma input function for the assessment of glucose metabolic rate and response to treatment.

    NARCIS (Netherlands)

    Vriens, D.; Geus-Oei, L.F. de; Oyen, W.J.G.; Visser, E.P.

    2009-01-01

    For the quantification of dynamic (18)F-FDG PET studies, the arterial plasma time-activity concentration curve (APTAC) needs to be available. This can be obtained using serial sampling of arterial blood or an image-derived input function (IDIF). Arterial sampling is invasive and often not feasible

  7. Recovery coefficients for the quantification of the arterial input function from dynamic pet measurements: experimental and theoretical determination

    International Nuclear Information System (INIS)

    Brix, G.; Bellemann, M.E.; Hauser, H.; Doll, J.

    2002-01-01

    Aim: For kinetic modelling of dynamic PET data, the arterial input function can be determined directly from the PET scans if a large artery is visualized on the images. It was the purpose of this study to experimentally and theoretically determine recovery coefficients for cylinders as a function of the diameter and level of background activity. Methods: The measurements were performed using a phantom with seven cylinder inserts (φ = 5-46 mm). The cylinders were filled with an aqueous 68 Ga solution while the main chamber was filled with a 18 F solution in order to obtain a varying concentration ratio between the cylinders and the background due to the different isotope half lives. After iterative image reconstruction, the activity concentrations were measured in the center of the cylinders and the recovery coefficients were calculated as a function of the diameter and the background activity. Based on the imaging properties of the PET system, we also developed a model for the quantitative assessment of recovery coefficients. Results: The functional dependence of the measured recovery data from the cylinder diameter and the concentration ratio is well described by our model. For dynamic PET measurements, the recovery correction must take into account the decreasing concentration ratio between the blood vessel and the surrounding tissue. Under the realized measurement and data analysis conditions, a recovery correction is required for vessels with a diameter of up to 25 mm. Conclusions: Based on the experimentally verified model, the activity concentration in large arteries can be calculated from the measured activity concentration in the blood vessel and the background activity. The presented approach offers the possibility to determine the arterial input function for pharmacokinetic PET studies non-invasively from large arteries (especially the aorta). (orig.) [de

  8. Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (I): Theory, method, and phantom experiments

    NARCIS (Netherlands)

    van Schie, Jeroen J. N.; Lavini, Cristina; van Vliet, Lucas J.; Vos, Frans M.

    2017-01-01

    The arterial input function (AIF) represents the time-dependent arterial contrast agent (CA) concentration that is used in pharmacokinetic modeling. To develop a novel method for estimating the AIF from dynamic contrast-enhanced (DCE-) MRI data, while compensating for flow enhancement. Signal

  9. Simplified quantification of small animal [{sup 18}F]FDG PET studies using a standard arterial input function

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Philipp T. [University Hospital Aachen, Department of Neurology, Aachen (Germany); Circiumaru, Valentina; Thomas, Daniel H. [University of Pennsylvania, Department of Radiology, Philadelphia (United States); Cardi, Christopher A.; Bal, Harshali; Acton, Paul D. [Thomas Jefferson University, Department of Radiology, Philadelphia (United States)

    2006-08-15

    Arterial input function (AIF) measurement for quantification of small animal PET studies is technically challenging and limited by the small blood volume of small laboratory animals. The present study investigated the use of a standard arterial input function (SAIF) to simplify the experimental procedure. Twelve [{sup 18}F]fluorodeoxyglucose ([{sup 18}F]FDG) PET studies accompanied by serial arterial blood sampling were acquired in seven male Sprague-Dawley rats under isoflurane anaesthesia without (every rat) and with additional (five rats) vibrissae stimulation. A leave-one-out procedure was employed to validate the use of a SAIF with individual scaling by one (1S) or two (2S) arterial blood samples. Automatic slow bolus infusion of [{sup 18}F]FDG resulted in highly similar AIF in all rats. The average differences of the area under the curve of the measured AIF and the individually scaled SAIF were 0.11{+-}4.26% and 0.04{+-}2.61% for the 1S (6-min sample) and the 2S (4-min/43-min samples) approach, respectively. The average differences between the cerebral metabolic rates of glucose (CMR{sub glc}) calculated using the measured AIF and the scaled SAIF were 1.31{+-}5.45% and 1.30{+-}3.84% for the 1S and the 2S approach, respectively. The use of a SAIF scaled by one or (preferably) two arterial blood samples can serve as a valid substitute for individual AIF measurements to quantify [{sup 18}F]FDG PET studies in rats. The SAIF approach minimises the loss of blood and should be ideally suited for longitudinal quantitative small animal [{sup 18}F]FDG PET studies. (orig.)

  10. Simultaneous acquisition of dynamic PET-MRI: arterial input function using DSC-MRI and [18F]-FET

    Energy Technology Data Exchange (ETDEWEB)

    Caldeira, Liliana; Yun, Seong Dae; Silva, Nuno da; Filss, Christian; Scheins, Juergen; Telmann, Lutz; Herzog, Hans; Shah, Jon [Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich GmbH (Germany)

    2015-05-18

    This work focuses on the study of simultaneous dynamic MR-PET acquisition in brain tumour patients. MR-based perfusion-weighted imaging (PWI) and PET [18F]-FET are dynamic methods, which allow to evaluate tumour metabolism in a quantitative way. In both methods, arterial input function (AIF) is necessary for quantification. However, the AIF estimation is a challenging task. In this work, we explore the possibilities to combine dynamic MR and PET AIF.

  11. Simultaneous acquisition of dynamic PET-MRI: arterial input function using DSC-MRI and [18F]-FET

    International Nuclear Information System (INIS)

    Caldeira, Liliana; Yun, Seong Dae; Silva, Nuno da; Filss, Christian; Scheins, Juergen; Telmann, Lutz; Herzog, Hans; Shah, Jon

    2015-01-01

    This work focuses on the study of simultaneous dynamic MR-PET acquisition in brain tumour patients. MR-based perfusion-weighted imaging (PWI) and PET [18F]-FET are dynamic methods, which allow to evaluate tumour metabolism in a quantitative way. In both methods, arterial input function (AIF) is necessary for quantification. However, the AIF estimation is a challenging task. In this work, we explore the possibilities to combine dynamic MR and PET AIF.

  12. Transcutaneous measurement of the arterial input function in positron emission tomography

    International Nuclear Information System (INIS)

    Litton, J.E.; Eriksson, L.

    1990-01-01

    Positron emission tomography (PET) provides a powerful tool in medical research. Biochemical function can be both precisely localized and quantitatively measured. To achieve reliable quantitation it is necessary to know the time course of activity concentration in the arterial blood during the measurement. In this study the arterial blood curve from the brachial artery is compared to the activity measured in the internal carotid artery with a new transcutaneous detector

  13. Simultaneous determination of arterial input function of the internal carotid and middle cerebral arteries for dynamic susceptibility contrast MRI

    International Nuclear Information System (INIS)

    Scholdei, R.; Wenz, F.; Fuss, M.; Essig, M.; Knopp, M.V.

    1999-01-01

    Purpose: The determination of the arterial input function (AIF) is necessary for absolute quantification of the regional cerebral blood volume and blood flow using dynamic susceptibility contrast MRI. The suitability of different vessels (ICA-internal carotid artery, MCA-middle cerebral artery) for AIF determination was compared in this study. Methods: A standard 1.5 T MR system and a simultaneous dual FLASH sequence (TR/TE1/TE2/α=32/15/25/10 ) were used to follow a bolus of contrast agent. Slice I was chosen to cut the ICA perpendicularly. Slice II included the MCA. Seventeen data sets from ten subjects were evaluated. Results: The number of AIF-relevant pixels, the area under the AIF and the maximum concentration were all lower when the AIF was determined from the MCA compared to the ICA. Additionally, the mean transit time (MTT) and the time to maximum concentration (TTM) were longer in the MCA, complicating the computerized identification of AIF-relevant pixels. Data from one subject, who was examined five times, demonstrated that the intraindividual variance of the measured parameters was markedly lower than the interpersonal variance. Conclusions: It appears to be advantageous to measure the AIF in the ICA rather than the MCA. (orig.) [de

  14. A curve-fitting approach to estimate the arterial plasma input function for the assessment of glucose metabolic rate and response to treatment.

    Science.gov (United States)

    Vriens, Dennis; de Geus-Oei, Lioe-Fee; Oyen, Wim J G; Visser, Eric P

    2009-12-01

    For the quantification of dynamic (18)F-FDG PET studies, the arterial plasma time-activity concentration curve (APTAC) needs to be available. This can be obtained using serial sampling of arterial blood or an image-derived input function (IDIF). Arterial sampling is invasive and often not feasible in practice; IDIFs are biased because of partial-volume effects and cannot be used when no large arterial blood pool is in the field of view. We propose a mathematic function, consisting of an initial linear rising activity concentration followed by a triexponential decay, to describe the APTAC. This function was fitted to 80 oncologic patients and verified for 40 different oncologic patients by area-under-the-curve (AUC) comparison, Patlak glucose metabolic rate (MR(glc)) estimation, and therapy response monitoring (Delta MR(glc)). The proposed function was compared with the gold standard (serial arterial sampling) and the IDIF. To determine the free parameters of the function, plasma time-activity curves based on arterial samples in 80 patients were fitted after normalization for administered activity (AA) and initial distribution volume (iDV) of (18)F-FDG. The medians of these free parameters were used for the model. In 40 other patients (20 baseline and 20 follow-up dynamic (18)F-FDG PET scans), this model was validated. The population-based curve, individually calibrated by AA and iDV (APTAC(AA/iDV)), by 1 late arterial sample (APTAC(1 sample)), and by the individual IDIF (APTAC(IDIF)), was compared with the gold standard of serial arterial sampling (APTAC(sampled)) using the AUC. Additionally, these 3 methods of APTAC determination were evaluated with Patlak MR(glc) estimation and with Delta MR(glc) for therapy effects using serial sampling as the gold standard. Excellent individual fits to the function were derived with significantly different decay constants (P AUC from APTAC(AA/iDV), APTAC(1 sample), and APTAC(IDIF) with the gold standard (APTAC(sampled)) were 0

  15. Determination of the arterial input function in mouse-models using clinical MRI

    International Nuclear Information System (INIS)

    Theis, D.; Fachhochschule Giessen-Friedberg; Keil, B.; Heverhagen, J.T.; Klose, K.J.; Behe, M.; Fiebich, M.

    2008-01-01

    Dynamic contrast enhanced magnetic resonance imaging is a promising method for quantitative analysis of tumor perfusion and is increasingly used in study of cancer in small animal models. In those studies the determination of the arterial input function (AIF) of the target tissue can be the first step. Series of short-axis images of the heart were acquired during administration of a bolus of Gd-DTPA using saturation-recovery gradient echo pulse sequences. The AIF was determined from the changes of the signal intensity in the left ventricle. The native T1 relaxation times and AIF were determined for 11 mice. An average value of (1.16 ± 0.09) s for the native T1 relaxation time was measured. However, the AIF showed significant inter animal variability, as previously observed by other authors. The inter-animal variability shows, that a direct measurement of the AIF is reasonable to avoid significant errors. The proposed method for determination of the AIF proved to be reliable. (orig.)

  16. Minimally invasive input function for 2-{sup 18}F-fluoro-A-85380 brain PET studies

    Energy Technology Data Exchange (ETDEWEB)

    Zanotti-Fregonara, Paolo [National Institute of Mental Health, NIH, Molecular Imaging Branch, Bethesda, MD (United States); Maroy, Renaud; Peyronneau, Marie-Anne; Trebossen, Regine [CEA, DSV, I2BM, Service Hospitalier Frederic Joliot, Orsay (France); Bottlaender, Michel [CEA, DSV, I2BM, NeuroSpin, Gif-sur-Yvette (France)

    2012-04-15

    Quantitative neuroreceptor positron emission tomography (PET) studies often require arterial cannulation to measure input function. While population-based input function (PBIF) would be a less invasive alternative, it has only rarely been used in conjunction with neuroreceptor PET tracers. The aims of this study were (1) to validate the use of PBIF for 2-{sup 18}F-fluoro-A-85380, a tracer for nicotinic receptors; (2) to compare the accuracy of measures obtained via PBIF to those obtained via blood-scaled image-derived input function (IDIF) from carotid arteries; and (3) to explore the possibility of using venous instead of arterial samples for both PBIF and IDIF. Ten healthy volunteers underwent a dynamic 2-{sup 18}F-fluoro-A-85380 brain PET scan with arterial and, in seven subjects, concurrent venous serial blood sampling. PBIF was obtained by averaging the normalized metabolite-corrected arterial input function and subsequently scaling each curve with individual blood samples. IDIF was obtained from the carotid arteries using a blood-scaling method. Estimated Logan distribution volume (V{sub T}) values were compared to the reference values obtained from arterial cannulation. For all subjects, PBIF curves scaled with arterial samples were similar in shape and magnitude to the reference arterial input function. The Logan V{sub T} ratio was 1.00 {+-} 0.05; all subjects had an estimation error <10%. IDIF gave slightly less accurate results (V{sub T} ratio 1.03 {+-} 0.07; eight of ten subjects had an error <10%). PBIF scaled with venous samples yielded inaccurate results (V{sub T} ratio 1.13 {+-} 0.13; only three of seven subjects had an error <10%). Due to arteriovenous differences at early time points, IDIF could not be calculated using venous samples. PBIF scaled with arterial samples accurately estimates Logan V{sub T} for 2-{sup 18}F-fluoro-A-85380. Results obtained with PBIF were slightly better than those obtained with IDIF. Due to arteriovenous concentration

  17. Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Tao; Tsui, Benjamin M. W.; Li, Xin; Vranesic, Melin; Lodge, Martin A.; Gulaldi, Nedim C. M.; Szabo, Zsolt, E-mail: zszabo@jhmi.edu [Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins School of Medicine, Baltimore, Maryland 21287 (United States)

    2015-11-15

    Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent

  18. Corrections of arterial input function for dynamic H215O PET to assess perfusion of pelvic tumours: arterial blood sampling versus image extraction

    International Nuclear Information System (INIS)

    Luedemann, L; Sreenivasa, G; Michel, R; Rosner, C; Plotkin, M; Felix, R; Wust, P; Amthauer, H

    2006-01-01

    Assessment of perfusion with 15 O-labelled water (H 2 15 O) requires measurement of the arterial input function (AIF). The arterial time activity curve (TAC) measured using the peripheral sampling scheme requires corrections for delay and dispersion. In this study, parametrizations with and without arterial spillover correction for fitting of the tissue curve are evaluated. Additionally, a completely noninvasive method for generation of the AIF from a dynamic positron emission tomography (PET) acquisition is applied to assess perfusion of pelvic tumours. This method uses a volume of interest (VOI) to extract the TAC from the femoral artery. The VOI TAC is corrected for spillover using a separate tissue TAC and for recovery by determining the recovery coefficient on a coregistered CT data set. The techniques were applied in five patients with pelvic tumours who underwent a total of 11 examinations. Delay and dispersion correction of the blood TAC without arterial spillover correction yielded in seven examinations solutions inconsistent with physiology. Correction of arterial spillover increased the fitting accuracy and yielded consistent results in all patients. Generation of an AIF from PET image data was investigated as an alternative to arterial blood sampling and was shown to have an intrinsic potential to determine the AIF noninvasively and reproducibly. The AIF extracted from a VOI in a dynamic PET scan was similar in shape to the blood AIF but yielded significantly higher tissue perfusion values (mean of 104.0 ± 52.0%) and lower partition coefficients (-31.6 ± 24.2%). The perfusion values and partition coefficients determined with the VOI technique have to be corrected in order to compare the results with those of studies using a blood AIF

  19. Partial volume effect (PVE) on the arterial input function (AIF) in T1-weighted perfusion imaging and limitations of the multiplicative rescaling approach

    DEFF Research Database (Denmark)

    Hansen, Adam Espe; Pedersen, Henrik; Rostrup, Egill

    2009-01-01

    The partial volume effect (PVE) on the arterial input function (AIF) remains a major obstacle to absolute quantification of cerebral blood flow (CBF) using MRI. This study evaluates the validity and performance of a commonly used multiplicative rescaling of the AIF to correct for the PVE. In a gr...

  20. Metabolic liver function measured in vivo by dynamic (18)F-FDGal PET/CT without arterial blood sampling.

    Science.gov (United States)

    Horsager, Jacob; Munk, Ole Lajord; Sørensen, Michael

    2015-01-01

    Metabolic liver function can be measured by dynamic PET/CT with the radio-labelled galactose-analogue 2-[(18)F]fluoro-2-deoxy-D-galactose ((18)F-FDGal) in terms of hepatic systemic clearance of (18)F-FDGal (K, ml blood/ml liver tissue/min). The method requires arterial blood sampling from a radial artery (arterial input function), and the aim of this study was to develop a method for extracting an image-derived, non-invasive input function from a volume of interest (VOI). Dynamic (18)F-FDGal PET/CT data from 16 subjects without liver disease (healthy subjects) and 16 patients with liver cirrhosis were included in the study. Five different input VOIs were tested: four in the abdominal aorta and one in the left ventricle of the heart. Arterial input function from manual blood sampling was available for all subjects. K*-values were calculated using time-activity curves (TACs) from each VOI as input and compared to the K-value calculated using arterial blood samples as input. Each input VOI was tested on PET data reconstructed with and without resolution modelling. All five image-derived input VOIs yielded K*-values that correlated significantly with K calculated using arterial blood samples. Furthermore, TACs from two different VOIs yielded K*-values that did not statistically deviate from K calculated using arterial blood samples. A semicircle drawn in the posterior part of the abdominal aorta was the only VOI that was successful for both healthy subjects and patients as well as for PET data reconstructed with and without resolution modelling. Metabolic liver function using (18)F-FDGal PET/CT can be measured without arterial blood samples by using input data from a semicircle VOI drawn in the posterior part of the abdominal aorta.

  1. Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (II): Applications in spine diagnostics and assessment of crohn's disease

    NARCIS (Netherlands)

    van Schie, Jeroen J. N.; Lavini, Cristina; van Vliet, Lucas J.; Kramer, Gem; Pieters-van den Bos, Indra; Marcus, J. T.; Stoker, Jaap; Vos, Frans M.

    2017-01-01

    Pharmacokinetic (PK) models can describe microvascular density and integrity. An essential component of PK models is the arterial input function (AIF) representing the time-dependent concentration of contrast agent (CA) in the blood plasma supplied to a tissue. To evaluate a novel method for

  2. The anterior cerebral artery is an appropriate arterial input function for perfusion-CT processing in patients with acute stroke

    International Nuclear Information System (INIS)

    Wintermark, Max; Lau, Benison C.; Chien, Jeffrey; Arora, Sandeep

    2008-01-01

    Dynamic perfusion-CT (PCT) with deconvolution requires an arterial input function (AIF) for postprocessing. In clinical settings, the anterior cerebral artery (ACA) is often chosen for simplicity. The goals of this study were to determine how the AIF selection influences PCT results in acute stroke patients and whether the ACA is an appropriate default AIF. We retrospectively identified consecutive patients suspected of hemispheric stroke of less than 48 h duration who were evaluated on admission by PCT. PCT datasets were postprocessed using multiple AIF, and cerebral blood volume (CBV) and flow (CBF), and mean transit time (MTT) values were measured in the corresponding territories. Results from corresponding territories in the same patients were compared using paired t-tests. The volumes of infarct core and tissue at risk obtained with different AIFs were compared to the final infarct volume. Of 113 patients who met the inclusion criteria, 55 with stroke were considered for analysis. The MTT values obtained with an ''ischemic'' AIF tended to be shorter (P=0.055) and the CBF values higher (P=0.108) than those obtained using a ''nonischemic'' AIF. CBV values were not influenced by the selection of the AIF. No statistically significant difference was observed between the size of the PCT infarct core (P=0.121) and tissue at risk (P=0.178), regardless of AIF selection. In acute stroke patients, the selection of the AIF has no statistically significant impact of the PCT results; standardization of the PCT postprocessing using the ACA as the default AIF is adequate. (orig.)

  3. Noninvasive quantification of cerebral metabolic rate for glucose in rats using 18F-FDG PET and standard input function

    Science.gov (United States)

    Hori, Yuki; Ihara, Naoki; Teramoto, Noboru; Kunimi, Masako; Honda, Manabu; Kato, Koichi; Hanakawa, Takashi

    2015-01-01

    Measurement of arterial input function (AIF) for quantitative positron emission tomography (PET) studies is technically challenging. The present study aimed to develop a method based on a standard arterial input function (SIF) to estimate input function without blood sampling. We performed 18F-fluolodeoxyglucose studies accompanied by continuous blood sampling for measurement of AIF in 11 rats. Standard arterial input function was calculated by averaging AIFs from eight anesthetized rats, after normalization with body mass (BM) and injected dose (ID). Then, the individual input function was estimated using two types of SIF: (1) SIF calibrated by the individual's BM and ID (estimated individual input function, EIFNS) and (2) SIF calibrated by a single blood sampling as proposed previously (EIF1S). No significant differences in area under the curve (AUC) or cerebral metabolic rate for glucose (CMRGlc) were found across the AIF-, EIFNS-, and EIF1S-based methods using repeated measures analysis of variance. In the correlation analysis, AUC or CMRGlc derived from EIFNS was highly correlated with those derived from AIF and EIF1S. Preliminary comparison between AIF and EIFNS in three awake rats supported an idea that the method might be applicable to behaving animals. The present study suggests that EIFNS method might serve as a noninvasive substitute for individual AIF measurement. PMID:25966947

  4. H∞ Control of Coronary Artery Input Time-Delay System via the Free-Matrix-Based Integral Inequality

    Directory of Open Access Journals (Sweden)

    Sha-sha Li

    2018-01-01

    Full Text Available The issue of H∞ control for the coronary artery input time-delay system with external disturbance is of concern. To further reduce conservation, we utilize the free-matrix-based integral inequality, Wirtinger-based integral inequality, and reciprocal convex combination approach to construct Lyapunov-Krasovskii function (LKF. Then a sufficient condition for controller design which can guarantee robust synchronization the coronary artery system is represented in terms of linear matrix inequality (LMI. Finally, a numerical example is exploited to show the effectiveness of the proposed methods.

  5. Relative sensitivities of DCE-MRI pharmacokinetic parameters to arterial input function (AIF) scaling.

    Science.gov (United States)

    Li, Xin; Cai, Yu; Moloney, Brendan; Chen, Yiyi; Huang, Wei; Woods, Mark; Coakley, Fergus V; Rooney, William D; Garzotto, Mark G; Springer, Charles S

    2016-08-01

    Dynamic-Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) has been used widely for clinical applications. Pharmacokinetic modeling of DCE-MRI data that extracts quantitative contrast reagent/tissue-specific model parameters is the most investigated method. One of the primary challenges in pharmacokinetic analysis of DCE-MRI data is accurate and reliable measurement of the arterial input function (AIF), which is the driving force behind all pharmacokinetics. Because of effects such as inflow and partial volume averaging, AIF measured from individual arteries sometimes require amplitude scaling for better representation of the blood contrast reagent (CR) concentration time-courses. Empirical approaches like blinded AIF estimation or reference tissue AIF derivation can be useful and practical, especially when there is no clearly visible blood vessel within the imaging field-of-view (FOV). Similarly, these approaches generally also require magnitude scaling of the derived AIF time-courses. Since the AIF varies among individuals even with the same CR injection protocol and the perfect scaling factor for reconstructing the ground truth AIF often remains unknown, variations in estimated pharmacokinetic parameters due to varying AIF scaling factors are of special interest. In this work, using simulated and real prostate cancer DCE-MRI data, we examined parameter variations associated with AIF scaling. Our results show that, for both the fast-exchange-limit (FXL) Tofts model and the water exchange sensitized fast-exchange-regime (FXR) model, the commonly fitted CR transfer constant (K(trans)) and the extravascular, extracellular volume fraction (ve) scale nearly proportionally with the AIF, whereas the FXR-specific unidirectional cellular water efflux rate constant, kio, and the CR intravasation rate constant, kep, are both AIF scaling insensitive. This indicates that, for DCE-MRI of prostate cancer and possibly other cancers, kio and kep may be more suitable imaging

  6. H ∞ synchronization of the coronary artery system with input time-varying delay

    International Nuclear Information System (INIS)

    Li Xiao-Meng; Zhao Zhan-Shan; Sun Lian-Kun; Zhang Jing

    2016-01-01

    This paper investigates the H ∞ synchronization of the coronary artery system with input delay and disturbance. We focus on reducing the conservatism of existing synchronization strategies. Base on the triple integral forms of the Lyapunov–Krasovskii functional (LKF), we utilize single and double integral forms of Wirtinger-based inequality to guarantee that the synchronization feedback controller has good performance against time-varying delay and external disturbance. The effectiveness of our strategy can be exhibited by simulations under the different time-varying delays and different disturbances. (paper)

  7. Comparison of K-means and fuzzy c-means algorithm performance for automated determination of the arterial input function.

    Science.gov (United States)

    Yin, Jiandong; Sun, Hongzan; Yang, Jiawen; Guo, Qiyong

    2014-01-01

    The arterial input function (AIF) plays a crucial role in the quantification of cerebral perfusion parameters. The traditional method for AIF detection is based on manual operation, which is time-consuming and subjective. Two automatic methods have been reported that are based on two frequently used clustering algorithms: fuzzy c-means (FCM) and K-means. However, it is still not clear which is better for AIF detection. Hence, we compared the performance of these two clustering methods using both simulated and clinical data. The results demonstrate that K-means analysis can yield more accurate and robust AIF results, although it takes longer to execute than the FCM method. We consider that this longer execution time is trivial relative to the total time required for image manipulation in a PACS setting, and is acceptable if an ideal AIF is obtained. Therefore, the K-means method is preferable to FCM in AIF detection.

  8. Improving the arterial input function in dynamic contrast enhanced MRI by fitting the signal in the complex plane.

    Science.gov (United States)

    Simonis, Frank F J; Sbrizzi, Alessandro; Beld, Ellis; Lagendijk, Jan J W; van den Berg, Cornelis A T

    2016-10-01

    Dynamic contrast enhanced (DCE) imaging is a widely used technique in oncologic imaging. An essential prerequisite for obtaining quantitative values from DCE-MRI is the determination of the arterial input function (AIF). However, it is very challenging to accurately estimate the AIF using MR. A comprehensive model, which uses complex data instead of either magnitude or phase, was developed to improve AIF estimation. The model was first applied to simulated data. Subsequently, the accuracy of the estimated contrast agent concentration was validated in a phantom. Finally the method was applied to existing DCE scans of 13 prostate cancer patients. The complex signal method combines the complementary strengths of the magnitude and phase method, increasing the precision and accuracy of concentration estimation in simulated and phantom data. The in vivo AIFs show a good agreement between arterial voxels (standard deviation in the peak and tail equal 0.4 mM and 0.12 mM, respectively). Furthermore, the dynamic behavior closely followed the AIF obtained with DCE-CT in the same patients (mean correlation coefficient: 0.92). By using the complex signal, the AIF estimation becomes more accurate and precise. This might enable patient specific AIFs, thereby improving the quantitative values obtained from DCE-MRI. Magn Reson Med 76:1236-1245, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  9. Estimation of the pulmonary input function in dynamic whole body PET

    International Nuclear Information System (INIS)

    Ho-Shon, K.; Buchen, P.; Meikle, S.R.; Fulham, M.J.; University of Sydney, Sydney, NSW

    1998-01-01

    Full text: Dynamic data acquisition in Whole Body PET (WB-PET) has the potential to measure the metabolic rate of glucose (MRGlc) in tissue in-vivo. Estimation of changes in tumoral MRGlc may be a valuable tool in cancer by providing an quantitative index of response to treatment. A necessary requirement is an input function (IF) that can be obtained from arterial, 'arterialised' venous or pulmonary arterial blood in the case of lung tumours. Our aim was to extract the pulmonary input function from dynamic WB-PET data using Principal Component Analysis (PCA), Factor Analysis (FA) and Maximum Entropy (ME) for the evaluation of patients undergoing induction chemotherapy for non-small cell lung cancer. PCA is first used as a method of dimension reduction to obtain a signal space, defined by an optimal metric and a set of vectors. FA is used together with a ME constraint to rotate these vectors to obtain 'physiological' factors. A form of entropy function that does not require normalised data was used. This enabled the introduction of a penalty function based on the blood concentration at the last time point which provides an additional constraint. Tissue functions from 10 planes through normal lung were simulated. The model was a linear combination of an IF and a tissue time activity curve (TAC). The proportion of the IF to TAC was varied over the planes to simulate the apical to basal gradient in vascularity of the lung and pseudo Poisson noise was added. The method accurately extracted the IF at noise levels spanning the expected range for dynamic ROI data acquired with the interplane septa extended. Our method is minimally invasive because it requires only 1 late venous blood sample and is applicable to a wide range of tracers since it does not assume a particular compartmental model. Pilot data from 2 patients have been collected enabling comparison of the estimated IF with direct blood sampling from the pulmonary artery

  10. Reconstruction of an input function from a dynamic PET water image using multiple tissue curves

    Science.gov (United States)

    Kudomi, Nobuyuki; Maeda, Yukito; Yamamoto, Yuka; Nishiyama, Yoshihiro

    2016-08-01

    Quantification of cerebral blood flow (CBF) is important for the understanding of normal and pathologic brain physiology. When CBF is assessed using PET with {{\\text{H}}2} 15O or C15O2, its calculation requires an arterial input function, which generally requires invasive arterial blood sampling. The aim of the present study was to develop a new technique to reconstruct an image derived input function (IDIF) from a dynamic {{\\text{H}}2} 15O PET image as a completely non-invasive approach. Our technique consisted of using a formula to express the input using tissue curve with rate constant parameter. For multiple tissue curves extracted from the dynamic image, the rate constants were estimated so as to minimize the sum of the differences of the reproduced inputs expressed by the extracted tissue curves. The estimated rates were used to express the inputs and the mean of the estimated inputs was used as an IDIF. The method was tested in human subjects (n  =  29) and was compared to the blood sampling method. Simulation studies were performed to examine the magnitude of potential biases in CBF and to optimize the number of multiple tissue curves used for the input reconstruction. In the PET study, the estimated IDIFs were well reproduced against the measured ones. The difference between the calculated CBF values obtained using the two methods was small as around  PET imaging. This suggests the possibility of using a completely non-invasive technique to assess CBF in patho-physiological studies.

  11. Development of Input Function Measurement System for Small Animal PET Study

    International Nuclear Information System (INIS)

    Kim, Jong Guk; Kim, Byung Su; Kim, Jin Su

    2010-01-01

    For quantitative measurement of radioactivity concentration in tissue and a validated tracer kinetic model, the high sensitive detection system has been required for blood sampling. With the accurate measurement of time activity curves (TACs) of labeled compounds in blood (plasma) enable to provide quantitative information on biological parameters of interest in local tissue. Especially, the development of new tracers for PET imaging requires knowledge of the kinetics of the tracer in the body and in arterial blood and plasma. Conventional approaches of obtaining an input function are to sample arterial blood sequentially by manual as a function of time. Several continuous blood sampling systems have been developed and used in nuclear medicine research field to overcome the limited temporal resolution in sampling by the conventional method. In this work, we developed the high sensitive and unique geometric design of GSO detector for small animal blood activity measurement

  12. Determination of arterial input function in dynamic susceptibility contrast MRI using group independent component analysis technique

    International Nuclear Information System (INIS)

    Chen, S.; Liu, H.-L.; Yang Yihong; Hsu, Y.-Y.; Chuang, K.-S.

    2006-01-01

    Quantification of cerebral blood flow (CBF) with dynamic susceptibility contrast (DSC) magnetic resonance imaging (MRI) requires the determination of the arterial input function (AIF). The segmentation of surrounding tissue by manual selection is error-prone due to the partial volume artifacts. Independent component analysis (ICA) has the advantage in automatically decomposing the signals into interpretable components. Recently group ICA technique has been applied to fMRI study and showed reduced variance caused by motion artifact and noise. In this work, we investigated the feasibility and efficacy of the use of group ICA technique to extract the AIF. Both simulated and in vivo data were analyzed in this study. The simulation data of eight phantoms were generated using randomized lesion locations and time activity curves. The clinical data were obtained from spin-echo EPI MR scans performed in seven normal subjects. Group ICA technique was applied to analyze data through concatenating across seven subjects. The AIFs were calculated from the weighted average of the signals in the region selected by ICA. Preliminary results of this study showed that group ICA technique could not extract accurate AIF information from regions around the vessel. The mismatched location of vessels within the group reduced the benefits of group study

  13. Fully automated calculation of image-derived input function in simultaneous PET/MRI in a sheep model

    International Nuclear Information System (INIS)

    Jochimsen, Thies H.; Zeisig, Vilia; Schulz, Jessica; Werner, Peter; Patt, Marianne; Patt, Jörg; Dreyer, Antje Y.; Boltze, Johannes; Barthel, Henryk; Sabri, Osama; Sattler, Bernhard

    2016-01-01

    Obtaining the arterial input function (AIF) from image data in dynamic positron emission tomography (PET) examinations is a non-invasive alternative to arterial blood sampling. In simultaneous PET/magnetic resonance imaging (PET/MRI), high-resolution MRI angiographies can be used to define major arteries for correction of partial-volume effects (PVE) and point spread function (PSF) response in the PET data. The present study describes a fully automated method to obtain the image-derived input function (IDIF) in PET/MRI. Results are compared to those obtained by arterial blood sampling. To segment the trunk of the major arteries in the neck, a high-resolution time-of-flight MRI angiography was postprocessed by a vessel-enhancement filter based on the inertia tensor. Together with the measured PSF of the PET subsystem, the arterial mask was used for geometrical deconvolution, yielding the time-resolved activity concentration averaged over a major artery. The method was compared to manual arterial blood sampling at the hind leg of 21 sheep (animal stroke model) during measurement of blood flow with O15-water. Absolute quantification of activity concentration was compared after bolus passage during steady state, i.e., between 2.5- and 5-min post injection. Cerebral blood flow (CBF) values from blood sampling and IDIF were also compared. The cross-calibration factor obtained by comparing activity concentrations in blood samples and IDIF during steady state is 0.98 ± 0.10. In all examinations, the IDIF provided a much earlier and sharper bolus peak than in the time course of activity concentration obtained by arterial blood sampling. CBF using the IDIF was 22 % higher than CBF obtained by using the AIF yielded by blood sampling. The small deviation between arterial blood sampling and IDIF during steady state indicates that correction of PVE and PSF is possible with the method presented. The differences in bolus dynamics and, hence, CBF values can be explained by the

  14. Fully automated calculation of image-derived input function in simultaneous PET/MRI in a sheep model

    Energy Technology Data Exchange (ETDEWEB)

    Jochimsen, Thies H.; Zeisig, Vilia [Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig (Germany); Schulz, Jessica [Max Planck Institute for Human Cognitive and Brain Sciences, Stephanstr. 1a, Leipzig, D-04103 (Germany); Werner, Peter; Patt, Marianne; Patt, Jörg [Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig (Germany); Dreyer, Antje Y. [Fraunhofer Institute of Cell Therapy and Immunology, Perlickstr. 1, Leipzig, D-04103 (Germany); Translational Centre for Regenerative Medicine, University Leipzig, Philipp-Rosenthal-Str. 55, Leipzig, D-04103 (Germany); Boltze, Johannes [Fraunhofer Institute of Cell Therapy and Immunology, Perlickstr. 1, Leipzig, D-04103 (Germany); Translational Centre for Regenerative Medicine, University Leipzig, Philipp-Rosenthal-Str. 55, Leipzig, D-04103 (Germany); Fraunhofer Research Institution of Marine Biotechnology and Institute for Medical and Marine Biotechnology, University of Lübeck, Lübeck (Germany); Barthel, Henryk; Sabri, Osama; Sattler, Bernhard [Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig (Germany)

    2016-02-13

    Obtaining the arterial input function (AIF) from image data in dynamic positron emission tomography (PET) examinations is a non-invasive alternative to arterial blood sampling. In simultaneous PET/magnetic resonance imaging (PET/MRI), high-resolution MRI angiographies can be used to define major arteries for correction of partial-volume effects (PVE) and point spread function (PSF) response in the PET data. The present study describes a fully automated method to obtain the image-derived input function (IDIF) in PET/MRI. Results are compared to those obtained by arterial blood sampling. To segment the trunk of the major arteries in the neck, a high-resolution time-of-flight MRI angiography was postprocessed by a vessel-enhancement filter based on the inertia tensor. Together with the measured PSF of the PET subsystem, the arterial mask was used for geometrical deconvolution, yielding the time-resolved activity concentration averaged over a major artery. The method was compared to manual arterial blood sampling at the hind leg of 21 sheep (animal stroke model) during measurement of blood flow with O15-water. Absolute quantification of activity concentration was compared after bolus passage during steady state, i.e., between 2.5- and 5-min post injection. Cerebral blood flow (CBF) values from blood sampling and IDIF were also compared. The cross-calibration factor obtained by comparing activity concentrations in blood samples and IDIF during steady state is 0.98 ± 0.10. In all examinations, the IDIF provided a much earlier and sharper bolus peak than in the time course of activity concentration obtained by arterial blood sampling. CBF using the IDIF was 22 % higher than CBF obtained by using the AIF yielded by blood sampling. The small deviation between arterial blood sampling and IDIF during steady state indicates that correction of PVE and PSF is possible with the method presented. The differences in bolus dynamics and, hence, CBF values can be explained by the

  15. An open tool for input function estimation and quantification of dynamic PET FDG brain scans.

    Science.gov (United States)

    Bertrán, Martín; Martínez, Natalia; Carbajal, Guillermo; Fernández, Alicia; Gómez, Álvaro

    2016-08-01

    Positron emission tomography (PET) analysis of clinical studies is mostly restricted to qualitative evaluation. Quantitative analysis of PET studies is highly desirable to be able to compute an objective measurement of the process of interest in order to evaluate treatment response and/or compare patient data. But implementation of quantitative analysis generally requires the determination of the input function: the arterial blood or plasma activity which indicates how much tracer is available for uptake in the brain. The purpose of our work was to share with the community an open software tool that can assist in the estimation of this input function, and the derivation of a quantitative map from the dynamic PET study. Arterial blood sampling during the PET study is the gold standard method to get the input function, but is uncomfortable and risky for the patient so it is rarely used in routine studies. To overcome the lack of a direct input function, different alternatives have been devised and are available in the literature. These alternatives derive the input function from the PET image itself (image-derived input function) or from data gathered from previous similar studies (population-based input function). In this article, we present ongoing work that includes the development of a software tool that integrates several methods with novel strategies for the segmentation of blood pools and parameter estimation. The tool is available as an extension to the 3D Slicer software. Tests on phantoms were conducted in order to validate the implemented methods. We evaluated the segmentation algorithms over a range of acquisition conditions and vasculature size. Input function estimation algorithms were evaluated against ground truth of the phantoms, as well as on their impact over the final quantification map. End-to-end use of the tool yields quantification maps with [Formula: see text] relative error in the estimated influx versus ground truth on phantoms. The main

  16. Evaluation of the use of a standard input function for compartment analysis of [123I]iomazenil data. Factors influencing the quantitative results

    International Nuclear Information System (INIS)

    Seike, Yujiro; Hashikawa, Kazuo; Oku, Naohiko

    2004-01-01

    Adoption of standard input function (SIF) has been proposed for kinetic analysis of receptor binding potential (BP), instead of invasive frequent arterial samplings. The purpose of this study was to assess the SIP method in quantitative analysis of [ 123 I]iomazenil (IMZ), a central benzodiazepine antagonist, for SPECT. SPECT studies were performed on 10 patients with cerebrovascular disease or Alzheimer disease. Intermittent dynamic SPECT scans were performed from 0 to 201 min after IMZ-injection. BPs calculated from SIFs obtained from normal volunteers (BP s ) were compared with those of individual arterial samplings (BP O ). Good correlations were shown between BP O s and BP S s in the 9 subjects, but maximum BP S s were four times larger than the corresponding BP O s in one case. There were no abnormal laboratory data in this patient, but the relative arterial input count in the late period was higher than the SIF. Simulation studies with modified input functions revealed that height in the late period can produce significant errors in estimated BPs. These results suggested that the simplified method with one-point arterial sampling and SIF can not be applied clinically. One additional arterial sampling in the late period may be useful. (author)

  17. Automatic detection of arterial input function in dynamic contrast enhanced MRI based on affinity propagation clustering.

    Science.gov (United States)

    Shi, Lin; Wang, Defeng; Liu, Wen; Fang, Kui; Wang, Yi-Xiang J; Huang, Wenhua; King, Ann D; Heng, Pheng Ann; Ahuja, Anil T

    2014-05-01

    To automatically and robustly detect the arterial input function (AIF) with high detection accuracy and low computational cost in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). In this study, we developed an automatic AIF detection method using an accelerated version (Fast-AP) of affinity propagation (AP) clustering. The validity of this Fast-AP-based method was proved on two DCE-MRI datasets, i.e., rat kidney and human head and neck. The detailed AIF detection performance of this proposed method was assessed in comparison with other clustering-based methods, namely original AP and K-means, as well as the manual AIF detection method. Both the automatic AP- and Fast-AP-based methods achieved satisfactory AIF detection accuracy, but the computational cost of Fast-AP could be reduced by 64.37-92.10% on rat dataset and 73.18-90.18% on human dataset compared with the cost of AP. The K-means yielded the lowest computational cost, but resulted in the lowest AIF detection accuracy. The experimental results demonstrated that both the AP- and Fast-AP-based methods were insensitive to the initialization of cluster centers, and had superior robustness compared with K-means method. The Fast-AP-based method enables automatic AIF detection with high accuracy and efficiency. Copyright © 2013 Wiley Periodicals, Inc.

  18. Semiautomatic determination of arterial input functions for quantitative dynamic contrast-enhanced magnetic resonance imaging in non-small cell lung cancer patients.

    Science.gov (United States)

    Chung, Julius; Kim, Jae-Hun; Lee, Eun Ju; Kim, Yoo Na; Yi, Chin A

    2015-03-01

    The aim of this study was to validate a semiautomatic detection method for the arterial input functions (AIFs) using Kendall coefficient of concordance (KCC) for quantitative analysis of dynamic contrast-enhanced magnetic resonance imaging in non-small cell lung cancer patients. We prospectively enrolled 28 patients (17 men, 11 women; mean age, 62 years) who had biopsy-proven non-small cell lung cancer. All enrolled patients underwent dynamic contrast-enhanced magnetic resonance imaging of the entire thorax. For the quantitative measurement of pharmacokinetic parameters, K and ve, of the lung cancers, AIFs were determined in 2 different ways: a manual method that involved 3 independent thoracic radiologists selecting a region of interest (ROI) within the aortic arch in the 2D coronal plane and a semiautomatic method that used in-house software to establish a KCC score, which provided a measure of similarity to typical AIF pattern. Three independent readers selected voxel clusters with high KCC scores calculated 3-dimensionally across planes in the data set. K and ve were correlated using intraclass correlation coefficients (ICCs), and Bland-Altman plots were used to examine agreement across methods and reproducibility within a method. Arterial input functions were determined using the data from ROI volumes that were significantly larger in the semiautomatic method (mean ± SD, 3360 ± 768 mm) than in the manual method (677 ± 380 mm) (P < 0.001). K showed very strong agreement (ICC, 0.927) and ve showed moderately strong agreement (ICC, 0.718) between the semiautomatic and manual methods. The reproducibility for K (ICCmanual, 0.813 and ICCsemiautomatic, 0.998; P < 0.001) and ve (ICCmanual, 0.455 and ICCsemiautomatic, 0.985, P < 0.001) was significantly better with the semiautomatic method than the manual method. We found semiautomated detection using KCC to be a robust method for determining the AIF. This method allows for larger ROIs specified in 3D across planes

  19. A simple method for measurement of cerebral blood flow using 123I-IMP SPECT with calibrated standard input function by one point blood sampling. Validation of calibration by one point venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Akaizawa, Takashi; Goto, Ryoui

    1994-01-01

    In a simplified method for measurement of cerebral blood flow using one 123 I-IMP SPECT scan and one point arterial blood sampling (Autoradiography method), input function is obtained by calibrating a standard input function by one point arterial blood sampling. A purpose of this study is validation of calibration by one point venous blood sampling as a substitute for one point arterial blood sampling. After intravenous infusion of 123 I-IMP, frequent arterial and venous blood sampling were simultaneously performed on 12 patients of CNS disease without any heart and lung disease and 5 normal volunteers. The radioactivity ratio of venous whole blood which obtained from cutaneous cubital vein to arterial whole blood were 0.76±0.08, 0.80±0.05, 0.81±0.06, 0.83±0.11 at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivities were always 20% lower than those of arterial blood radioactivity during 50 min. However, the ratio which obtained from cutaneous dorsal hand vein to artery were 0.93±0.02, 0.94±0.05, 0.98±0.04, 0.98±0.03, at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivity was consistent with artery. These indicate that arterio-venous difference of radioactivity in a peripheral cutaneous vein like a dorsal hand vein is minimal due to arteriovenous shunt in palm. Therefore, a substitution by blood sampling from cutaneous dorsal hand vein for artery will be possible. Optimized time for venous blood sampling evaluated by error analysis was 20 min after 123 I-IMP infusion, which is 10 min later than that of arterial blood sampling. (author)

  20. Cerebral blood flow with [15O]water PET studies using an image-derived input function and MR-defined carotid centerlines

    Science.gov (United States)

    Fung, Edward K.; Carson, Richard E.

    2013-03-01

    Full quantitative analysis of brain PET data requires knowledge of the arterial input function into the brain. Such data are normally acquired by arterial sampling with corrections for delay and dispersion to account for the distant sampling site. Several attempts have been made to extract an image-derived input function (IDIF) directly from the internal carotid arteries that supply the brain and are often visible in brain PET images. We have devised a method of delineating the internal carotids in co-registered magnetic resonance (MR) images using the level-set method and applying the segmentations to PET images using a novel centerline approach. Centerlines of the segmented carotids were modeled as cubic splines and re-registered in PET images summed over the early portion of the scan. Using information from the anatomical center of the vessel should minimize partial volume and spillover effects. Centerline time-activity curves were taken as the mean of the values for points along the centerline interpolated from neighboring voxels. A scale factor correction was derived from calculation of cerebral blood flow (CBF) using gold standard arterial blood measurements. We have applied the method to human subject data from multiple injections of [15O]water on the HRRT. The method was assessed by calculating the area under the curve (AUC) of the IDIF and the CBF, and comparing these to values computed using the gold standard arterial input curve. The average ratio of IDIF to arterial AUC (apparent recovery coefficient: aRC) across 9 subjects with multiple (n = 69) injections was 0.49 ± 0.09 at 0-30 s post tracer arrival, 0.45 ± 0.09 at 30-60 s, and 0.46 ± 0.09 at 60-90 s. Gray and white matter CBF values were 61.4 ± 11.0 and 15.6 ± 3.0 mL/min/100 g tissue using sampled blood data. Using IDIF centerlines scaled by the average aRC over each subjects’ injections, gray and white matter CBF values were 61.3 ± 13.5 and 15.5 ± 3.4 mL/min/100 g tissue. Using global

  1. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    Science.gov (United States)

    Winant, Celeste D.; Aparici, Carina Mari; Zelnik, Yuval R.; Reutter, Bryan W.; Sitek, Arkadiusz; Bacharach, Stephen L.; Gullberg, Grant T.

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94Tc-methoxyisobutylisonitrile (94Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99mTc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal maximum

  2. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    International Nuclear Information System (INIS)

    Winant, Celeste D; Aparici, Carina Mari; Bacharach, Stephen L; Gullberg, Grant T; Zelnik, Yuval R; Reutter, Bryan W; Sitek, Arkadiusz

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94 Tc-methoxyisobutylisonitrile ( 94 Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K 1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K 1 . For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94 Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99m Tc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal

  3. Automatic individual arterial input functions calculated from PCA outperform manual and population-averaged approaches for the pharmacokinetic modeling of DCE-MR images.

    Science.gov (United States)

    Sanz-Requena, Roberto; Prats-Montalbán, José Manuel; Martí-Bonmatí, Luis; Alberich-Bayarri, Ángel; García-Martí, Gracián; Pérez, Rosario; Ferrer, Alberto

    2015-08-01

    To introduce a segmentation method to calculate an automatic arterial input function (AIF) based on principal component analysis (PCA) of dynamic contrast enhanced MR (DCE-MR) imaging and compare it with individual manually selected and population-averaged AIFs using calculated pharmacokinetic parameters. The study included 65 individuals with prostate examinations (27 tumors and 38 controls). Manual AIFs were individually extracted and also averaged to obtain a population AIF. Automatic AIFs were individually obtained by applying PCA to volumetric DCE-MR imaging data and finding the highest correlation of the PCs with a reference AIF. Variability was assessed using coefficients of variation and repeated measures tests. The different AIFs were used as inputs to the pharmacokinetic model and correlation coefficients, Bland-Altman plots and analysis of variance tests were obtained to compare the results. Automatic PCA-based AIFs were successfully extracted in all cases. The manual and PCA-based AIFs showed good correlation (r between pharmacokinetic parameters ranging from 0.74 to 0.95), with differences below the manual individual variability (RMSCV up to 27.3%). The population-averaged AIF showed larger differences (r from 0.30 to 0.61). The automatic PCA-based approach minimizes the variability associated to obtaining individual volume-based AIFs in DCE-MR studies of the prostate. © 2014 Wiley Periodicals, Inc.

  4. Separation of input function for rapid measurement of quantitative CMRO2 and CBF in a single PET scan with a dual tracer administration method

    International Nuclear Information System (INIS)

    Kudomi, Nobuyuki; Watabe, Hiroshi; Hayashi, Takuya; Iida, Hidehiro

    2007-01-01

    Cerebral metabolic rate of oxygen (CMRO 2 ), oxygen extraction fraction (OEF) and cerebral blood flow (CBF) images can be quantified using positron emission tomography (PET) by administrating 15 O-labelled water (H 15 2 O) and oxygen ( 15 O 2 ). Conventionally, those images are measured with separate scans for three tracers C 15 O for CBV, H 15 2 O for CBF and 15 O 2 for CMRO 2 , and there are additional waiting times between the scans in order to minimize the influence of the radioactivity from the previous tracers, which results in a relatively long study period. We have proposed a dual tracer autoradiographic (DARG) approach (Kudomi et al 2005), which enabled us to measure CBF, OEF and CMRO 2 rapidly by sequentially administrating H 15 2 O and 15 O 2 within a short time. Because quantitative CBF and CMRO 2 values are sensitive to arterial input function, it is necessary to obtain accurate input function and a drawback of this approach is to require separation of the measured arterial blood time-activity curve (TAC) into pure water and oxygen input functions under the existence of residual radioactivity from the first injected tracer. For this separation, frequent manual sampling was required. The present paper describes two calculation methods: namely a linear and a model-based method, to separate the measured arterial TAC into its water and oxygen components. In order to validate these methods, we first generated a blood TAC for the DARG approach by combining the water and oxygen input functions obtained in a series of PET studies on normal human subjects. The combined data were then separated into water and oxygen components by the present methods. CBF and CMRO 2 were calculated using those separated input functions and tissue TAC. The quantitative accuracy in the CBF and CMRO 2 values by the DARG approach did not exceed the acceptable range, i.e., errors in those values were within 5%, when the area under the curve in the input function of the second tracer

  5. Comparison of arterial input functions measured from ultra-fast dynamic contrast enhanced MRI and dynamic contrast enhanced computed tomography in prostate cancer patients

    Science.gov (United States)

    Wang, Shiyang; Lu, Zhengfeng; Fan, Xiaobing; Medved, Milica; Jiang, Xia; Sammet, Steffen; Yousuf, Ambereen; Pineda, Federico; Oto, Aytekin; Karczmar, Gregory S.

    2018-02-01

    The purpose of this study was to evaluate the accuracy of arterial input functions (AIFs) measured from dynamic contrast enhanced (DCE) MRI following a low dose of contrast media injection. The AIFs measured from DCE computed tomography (CT) were used as ‘gold standard’. A total of twenty patients received CT and MRI scans on the same day. Patients received 120 ml Iohexol in DCE-CT and a low dose of (0.015 mM kg-1) of gadobenate dimeglumine in DCE-MRI. The AIFs were measured in the iliac artery and normalized to the CT and MRI contrast agent doses. To correct for different temporal resolution and sampling periods of CT and MRI, an empirical mathematical model (EMM) was used to fit the AIFs first. Then numerical AIFs (AIFCT and AIFMRI) were calculated based on fitting parameters. The AIFMRI was convolved with a ‘contrast agent injection’ function (AIFMRICON ) to correct for the difference between MRI and CT contrast agent injection times (~1.5 s versus 30 s). The results show that the EMMs accurately fitted AIFs measured from CT and MRI. There was no significant difference (p  >  0.05) between the maximum peak amplitude of AIFs from CT (22.1  ±  4.1 mM/dose) and MRI after convolution (22.3  ±  5.2 mM/dose). The shapes of the AIFCT and AIFMRICON were very similar. Our results demonstrated that AIFs can be accurately measured by MRI following low dose contrast agent injection.

  6. The quantitative regional cerebral blood flow measurement with autoradiography method using 123I-IMP SPECT. Evaluation of arterialized venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ohnishi, Takashi; Yano, Takao; Nakano, Shinichi; Jinnouchi, Seishi; Nagamachi, Shigeki; Flores, L. II; Nakahara, Hiroshi; Watanabe, Katsushi.

    1996-01-01

    The purpose of this study is validation of calibrating a standard input function in autoradiography (ARG) method by one point venous blood sampling as a substitute for that by one point arterial blood sampling. Ten and 20 minutes after intravenous constant infusion of 123 I-IMP, arterialized venous blood sampling from a dorsal vein were performed on 15 patients having ischemic cerebrovascular disease. And arterial blood sampling from radial artery was performed 10 min after 123 I-IMP infusion. The mean difference rates of integrated input function between calibrated standard input function by arterial blood sampling at 10 min and that by venous blood sampling were 4.1±3% and 9.3±5.4% at 10 and 20 min after 123 I-IMP infusion, respectively. The ratio of venous blood radioactivity to arterial blood radioactivity at 10 min after 123 I-IMP infusion was 0.96±0.02. There was an excellent correlation between ARG method CBF values obtained by arterial blood sampling at 10 min and those obtained by arterialized venous blood sampling at 10 min. In conclusion, a substitution by arterialized venous blood sampling from dorsal hand vein for artery can be possible. The optimized time for arterialized venous blood sampling was 10 min after 123 I-IMP infusion. (author)

  7. Estimation of the input function in dynamic positron emission tomography applied to fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Jouvie, Camille

    2013-01-01

    Positron Emission Tomography (PET) is a method of functional imaging, used in particular for drug development and tumor imaging. In PET, the estimation of the arterial plasmatic activity concentration of the non-metabolized compound (the 'input function') is necessary for the extraction of the pharmacokinetic parameters. These parameters enable the quantification of the compound dynamics in the tissues. This PhD thesis contributes to the study of the input function by the development of a minimally invasive method to estimate the input function. This method uses the PET image and a few blood samples. In this work, the example of the FDG tracer is chosen. The proposed method relies on compartmental modeling: it deconvoluates the three-compartment-model. The originality of the method consists in using a large number of regions of interest (ROIs), a large number of sets of three ROIs, and an iterative process. To validate the method, simulations of PET images of increasing complexity have been performed, from a simple image simulated with an analytic simulator to a complex image simulated with a Monte-Carlo simulator. After simulation of the acquisition, reconstruction and corrections, the images were segmented (through segmentation of an IRM image and registration between PET and IRM images) and corrected for partial volume effect by a variant of Rousset's method, to obtain the kinetics in the ROIs, which are the input data of the estimation method. The evaluation of the method on simulated and real data is presented, as well as a study of the method robustness to different error sources, for example in the segmentation, in the registration or in the activity of the used blood samples. (author) [fr

  8. Combining MRI with PET for partial volume correction improves image-derived input functions in mice

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Eleanor; Buonincontri, Guido [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Izquierdo, David [Athinoula A Martinos Centre, Harvard University, Cambridge, MA (United States); Methner, Carmen [Department of Medicine, University of Cambridge, Cambridge (United Kingdom); Hawkes, Rob C [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Ansorge, Richard E [Department of Physics, University of Cambridge, Cambridge (United Kingdom); Kreig, Thomas [Department of Medicine, University of Cambridge, Cambridge (United Kingdom); Carpenter, T Adrian [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Sawiak, Stephen J [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Behavioural and Clinical Neurosciences Institute, University of Cambridge, Cambridge (United Kingdom)

    2014-07-29

    Kinetic modelling in PET requires the arterial input function (AIF), defined as the time-activity curve (TAC) in plasma. This measure is challenging to obtain in mice due to low blood volumes, resulting in a reliance on image-based methods for AIF derivation. We present a comparison of PET- and MR-based region-of-interest (ROI) analysis to obtain image-derived AIFs from the left ventricle (LV) of a mouse model. ROI-based partial volume correction (PVC) was performed to improve quantification.

  9. Combining MRI with PET for partial volume correction improves image-derived input functions in mice

    International Nuclear Information System (INIS)

    Evans, Eleanor; Buonincontri, Guido; Izquierdo, David; Methner, Carmen; Hawkes, Rob C; Ansorge, Richard E; Kreig, Thomas; Carpenter, T Adrian; Sawiak, Stephen J

    2014-01-01

    Kinetic modelling in PET requires the arterial input function (AIF), defined as the time-activity curve (TAC) in plasma. This measure is challenging to obtain in mice due to low blood volumes, resulting in a reliance on image-based methods for AIF derivation. We present a comparison of PET- and MR-based region-of-interest (ROI) analysis to obtain image-derived AIFs from the left ventricle (LV) of a mouse model. ROI-based partial volume correction (PVC) was performed to improve quantification.

  10. Evidence for reduced arterial plasma input, prolonged lung retention and reduced lung monoamine oxidase in smokers

    International Nuclear Information System (INIS)

    Logan, Jean; Fowler, Joanna S.

    2005-01-01

    We have previously found that smokers have reduced brain monoamine oxidase (MAO) A and B using positron emission tomography (PET) and the irreversible mechanism-based radiotracers [ 11 C]-labeled clorgyline (CLG) and deprenyl (DEP) and their deuterated analogs (D CLG, D DEP). More recently, we have estimated MAO A and B activity in other organs using the deuterium isotope effect to determine binding specificity for MAO and a three-compartment model to estimate k 3 , the model term proportional to MAO A activity. Here, we have investigated the robustness of the model term k 3 for estimating lung MAO A and B in light of our unexpected finding that lung MAO activity (k 3 ) was reduced for smokers relative to nonsmokers, although radiotracer uptake in the lungs was similar at peak and plateau for the two groups. Methods: Time-activity data from lung and arterial plasma were used from seven nonsmokers and seven smokers scanned previously with CLG and D CLG, and five nonsmokers and nine smokers scanned previously with DEP and D DEP. The measured time-activity curves for lung and plasma and the integrals for the arterial plasma time-activity curves were compared at an early time point (2.5 min) and at the end of the study (55 min). A three-compartment irreversible model was used to estimate the differences between smokers and nonsmokers, and the stability of the parameter (k 3 ) while varying model assumptions for the relative fractions of lung tissue, blood and air in the PET voxel. Results: The peak in the arterial plasma input function and the integral of the arterial plasma time-activity curve over the first 2.5 min after radiotracer injection were significantly lower for smokers relative to nonsmokers for all four tracers. However, although the peak and plateau of the lung time-activity curves were similar for smokers and nonsmokers, the decline in radioactivity from peak to plateau was slower for smokers for all tracers. Using a three-compartment irreversible model

  11. Arterial endothelial function measurement method and apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Maltz, Jonathan S; Budinger, Thomas F

    2014-03-04

    A "relaxoscope" (100) detects the degree of arterial endothelial function. Impairment of arterial endothelial function is an early event in atherosclerosis and correlates with the major risk factors for cardiovascular disease. An artery (115), such as the brachial artery (BA) is measured for diameter before and after several minutes of either vasoconstriction or vasorelaxation. The change in arterial diameter is a measure of flow-mediated vasomodification (FMVM). The relaxoscope induces an artificial pulse (128) at a superficial radial artery (115) via a linear actuator (120). An ultrasonic Doppler stethoscope (130) detects this pulse 10-20 cm proximal to the point of pulse induction (125). The delay between pulse application and detection provides the pulse transit time (PTT). By measuring PTT before (160) and after arterial diameter change (170), FMVM may be measured based on the changes in PTT caused by changes in vessel caliber, smooth muscle tone and wall thickness.

  12. Liver kinetics of glucose analogs measured in pigs by PET: importance of dual-input blood sampling

    DEFF Research Database (Denmark)

    Munk, O L; Bass, L; Roelsgaard, K

    2001-01-01

    -input functions were very similar. CONCLUSION: Compartmental analysis of MG and FDG kinetics using dynamic PET data requires measurements of dual-input activity concentrations. Using the dual-input function, physiologically reasonable parameter estimates of K1, k2, and Vp were obtained, whereas the use......Metabolic processes studied by PET are quantified traditionally using compartmental models, which relate the time course of the tracer concentration in tissue to that in arterial blood. For liver studies, the use of arterial input may, however, cause systematic errors to the estimated kinetic...... parameters, because of ignorance of the dual blood supply from the hepatic artery and the portal vein to the liver. METHODS: Six pigs underwent PET after [15O]carbon monoxide inhalation, 3-O-[11C]methylglucose (MG) injection, and [18F]FDG injection. For the glucose scans, PET data were acquired for 90 min...

  13. Measurement of the arterial concentration of Gd-DTPA using MRI: a step toward quantitative perfusion imaging

    DEFF Research Database (Denmark)

    Fritz-Hansen, T; Rostrup, Egill; Larsson, H B

    1996-01-01

    A noninvasive method using an inversion recovery turbo-FLASH for dynamic measurement of the arterial input function represented by the bolus passage of Gd-DTPA in the descending aorta is presented, and the results are compared with the input function obtained by arterial blood samples. A good...... accordance between the two input functions was found, indicating that it is possible to measure the input function to the myocardium using MRI. A variation between the two concentration curves of 5% at upslope, 2.7% at peak point, and ... inversion time peak concentration....

  14. Arterial function of carotid and brachial arteries in postmenopausal vegetarians

    Directory of Open Access Journals (Sweden)

    Su T

    2011-08-01

    Full Text Available Ta-Chen Su1, Pao-Ling Torng2, Jiann-Shing Jeng3, Ming-Fong Chen1, Chiau-Suong Liau1,41Division of Cardiology, Department of Internal Medicine, 2Department of Obstetrics and Gynecology, 3Department of Neurology, National Taiwan University Hospital, National Taiwan University College of Medicine, 4Cardiovascular Center, Taipei Buddist Tzu-Chi Hospital, Hsin-Dian, Taipei, TaiwanBackground: Vegetarianism is associated with a lower risk of cardiovascular disease. However, studies of arterial function in vegetarians are limited.Methods: This study investigated arterial function in vegetarianism by comparing 49 healthy postmenopausal vegetarians with 41 age-matched omnivores. The arterial function of the common carotid artery was assessed by carotid duplex, while the pulse dynamics method was used to measure brachial artery distensibility (BAD, compliance (BAC, and resistance (BAR. Fasting blood levels of glucose, lipids, lipoprotein (a, high-sensitivity C-reactive protein, homocysteine, and vitamin B12 were also measured.Results: Vegetarians had significantly lower serum cholesterol, high-density and low-density lipoprotein, and glucose compared with omnivores. They also had lower vitamin B12 but higher homocysteine levels. Serum levels of lipoprotein (a and high-sensitivity C-reactive protein were no different between the two groups. There were no significant differences in carotid beta stiffness index, BAC, and BAD between the two groups even after adjustment for associated covariates. However, BAR was significantly lower in vegetarians than in omnivores. Multiple linear regression analysis revealed that age and pulse pressure were two important determinants of carotid beta stiffness index and BAD. Vegetarianism is not associated with better arterial elasticity.Conclusion: Apparently healthy postmenopausal vegetarians are not significantly better in terms of carotid beta stiffness index, BAC, and BAD, but have significantly decreased BAR than

  15. Preliminary evaluation of MRI-derived input function for quantitative measurement of glucose metabolism in an integrated PET-MRI

    International Nuclear Information System (INIS)

    Anazodo, Udunna; Kewin, Matthew; Finger, Elizabeth; Thiessen, Jonathan; Hadway, Jennifer; Butler, John; Pavlosky, William; Prato, Frank; Thompson, Terry; St Lawrence, Keith

    2015-01-01

    PET semi-quantitative methods such as relative uptake value can be robust but offer no biological information and do not account for intra-subject variability in tracer administration or clearance. Simultaneous multimodal measurements that combine PET and MRI not only permit crucial multiparametric measurements, it provides means of applying tracer kinetic modelling without the need for serial arterial blood sampling. In this study we adapted an image-derived input function (IDIF) method to improve characterization of glucose metabolism in an ongoing dementia study. Here we present preliminary results in a small group of frontotemporal dementia patients and controls. IDIF was obtained directly from dynamic PET data guided by regions of interest drawn on carotid vessels on high resolution T1-weighted MR Images. IDIF was corrected for contamination of non-arterial voxels. A validation of the method was performed in a porcine model in a PET-CT scanner comparing IDIF to direct arterial blood samples. Metabolic rate of glucose (CMRglc) was measured voxel-by-voxel in gray matter producing maps that were compared between groups. Net influx rate (Ki) and global mean CMRglc are reported. A good correlation (r = 0.9 p<0.0001) was found between corrected IDIF and input function measured from direct arterial blood sampling in the validation study. In 3 FTD and 3 controls, a trend towards hypometabolism was found in frontal, temporal and parietal lobes similar to significant differences previously reported by other groups. The global mean CMRglc and Ki observed in control subjects are in line with previous reports. In general, kinetic modelling of PET-FDG using an MR-IDIF can improve characterization of glucose metabolism in dementia. This method is feasible in multimodal studies that aim to combine PET molecular imaging with MRI as dynamic PET can be acquired along with multiple MRI measurements.

  16. Preliminary evaluation of MRI-derived input function for quantitative measurement of glucose metabolism in an integrated PET-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Anazodo, Udunna; Kewin, Matthew [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada); Finger, Elizabeth [Department of Clinical Neurological Sciences, Western University, London, Ontario (Canada); Thiessen, Jonathan; Hadway, Jennifer; Butler, John [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada); Pavlosky, William [Diagnostic Imaging, St Joseph' s Health Care, London, Ontario (Canada); Prato, Frank; Thompson, Terry; St Lawrence, Keith [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada)

    2015-05-18

    PET semi-quantitative methods such as relative uptake value can be robust but offer no biological information and do not account for intra-subject variability in tracer administration or clearance. Simultaneous multimodal measurements that combine PET and MRI not only permit crucial multiparametric measurements, it provides means of applying tracer kinetic modelling without the need for serial arterial blood sampling. In this study we adapted an image-derived input function (IDIF) method to improve characterization of glucose metabolism in an ongoing dementia study. Here we present preliminary results in a small group of frontotemporal dementia patients and controls. IDIF was obtained directly from dynamic PET data guided by regions of interest drawn on carotid vessels on high resolution T1-weighted MR Images. IDIF was corrected for contamination of non-arterial voxels. A validation of the method was performed in a porcine model in a PET-CT scanner comparing IDIF to direct arterial blood samples. Metabolic rate of glucose (CMRglc) was measured voxel-by-voxel in gray matter producing maps that were compared between groups. Net influx rate (Ki) and global mean CMRglc are reported. A good correlation (r = 0.9 p<0.0001) was found between corrected IDIF and input function measured from direct arterial blood sampling in the validation study. In 3 FTD and 3 controls, a trend towards hypometabolism was found in frontal, temporal and parietal lobes similar to significant differences previously reported by other groups. The global mean CMRglc and Ki observed in control subjects are in line with previous reports. In general, kinetic modelling of PET-FDG using an MR-IDIF can improve characterization of glucose metabolism in dementia. This method is feasible in multimodal studies that aim to combine PET molecular imaging with MRI as dynamic PET can be acquired along with multiple MRI measurements.

  17. Plasticity of the cis-regulatory input function of a gene.

    Directory of Open Access Journals (Sweden)

    Avraham E Mayo

    2006-04-01

    Full Text Available The transcription rate of a gene is often controlled by several regulators that bind specific sites in the gene's cis-regulatory region. The combined effect of these regulators is described by a cis-regulatory input function. What determines the form of an input function, and how variable is it with respect to mutations? To address this, we employ the well-characterized lac operon of Escherichia coli, which has an elaborate input function, intermediate between Boolean AND-gate and OR-gate logic. We mapped in detail the input function of 12 variants of the lac promoter, each with different point mutations in the regulator binding sites, by means of accurate expression measurements from living cells. We find that even a few mutations can significantly change the input function, resulting in functions that resemble Pure AND gates, OR gates, or single-input switches. Other types of gates were not found. The variant input functions can be described in a unified manner by a mathematical model. The model also lets us predict which functions cannot be reached by point mutations. The input function that we studied thus appears to be plastic, in the sense that many of the mutations do not ruin the regulation completely but rather result in new ways to integrate the inputs.

  18. Average arterial input function for quantitative dynamic contrast enhanced magnetic resonance imaging of neck nodal metastases

    International Nuclear Information System (INIS)

    Shukla-Dave, Amita; Lee, Nancy; Stambuk, Hilda; Wang, Ya; Huang, Wei; Thaler, Howard T; Patel, Snehal G; Shah, Jatin P; Koutcher, Jason A

    2009-01-01

    The present study determines the feasibility of generating an average arterial input function (Avg-AIF) from a limited population of patients with neck nodal metastases to be used for pharmacokinetic modeling of dynamic contrast-enhanced MRI (DCE-MRI) data in clinical trials of larger populations. Twenty patients (mean age 50 years [range 27–77 years]) with neck nodal metastases underwent pretreatment DCE-MRI studies with a temporal resolution of 3.75 to 7.5 sec on a 1.5T clinical MRI scanner. Eleven individual AIFs (Ind-AIFs) met the criteria of expected enhancement pattern and were used to generate Avg-AIF. Tofts model was used to calculate pharmacokinetic DCE-MRI parameters. Bland-Altman plots and paired Student t-tests were used to describe significant differences between the pharmacokinetic parameters obtained from individual and average AIFs. Ind-AIFs obtained from eleven patients were used to calculate the Avg-AIF. No overall significant difference (bias) was observed for the transfer constant (K trans ) measured with Ind-AIFs compared to Avg-AIF (p = 0.20 for region-of-interest (ROI) analysis and p = 0.18 for histogram median analysis). Similarly, no overall significant difference was observed for interstitial fluid space volume fraction (v e ) measured with Ind-AIFs compared to Avg-AIF (p = 0.48 for ROI analysis and p = 0.93 for histogram median analysis). However, the Bland-Altman plot suggests that as K trans increases, the Ind-AIF estimates tend to become proportionally higher than the Avg-AIF estimates. We found no statistically significant overall bias in K trans or v e estimates derived from Avg-AIF, generated from a limited population, as compared with Ind-AIFs. However, further study is needed to determine whether calibration is needed across the range of K trans . The Avg-AIF obtained from a limited population may be used for pharmacokinetic modeling of DCE-MRI data in larger population studies with neck nodal metastases. Further validation of

  19. Quantitative contrast-enhanced first-pass cardiac perfusion MRI at 3 tesla with accurate arterial input function and myocardial wall enhancement.

    Science.gov (United States)

    Breton, Elodie; Kim, Daniel; Chung, Sohae; Axel, Leon

    2011-09-01

    To develop, and validate in vivo, a robust quantitative first-pass perfusion cardiovascular MR (CMR) method with accurate arterial input function (AIF) and myocardial wall enhancement. A saturation-recovery (SR) pulse sequence was modified to sequentially acquire multiple slices after a single nonselective saturation pulse at 3 Tesla. In each heartbeat, an AIF image is acquired in the aortic root with a short time delay (TD) (50 ms), followed by the acquisition of myocardial images with longer TD values (∼150-400 ms). Longitudinal relaxation rates (R(1) = 1/T(1)) were calculated using an ideal saturation recovery equation based on the Bloch equation, and corresponding gadolinium contrast concentrations were calculated assuming fast water exchange condition. The proposed method was validated against a reference multi-point SR method by comparing their respective R(1) measurements in the blood and left ventricular myocardium, before and at multiple time-points following contrast injections, in 7 volunteers. R(1) measurements with the proposed method and reference multi-point method were strongly correlated (r > 0.88, P < 10(-5)) and in good agreement (mean difference ±1.96 standard deviation 0.131 ± 0.317/0.018 ± 0.140 s(-1) for blood/myocardium, respectively). The proposed quantitative first-pass perfusion CMR method measured accurate R(1) values for quantification of AIF and myocardial wall contrast agent concentrations in 3 cardiac short-axis slices, in a total acquisition time of 523 ms per heartbeat. Copyright © 2011 Wiley-Liss, Inc.

  20. Quantitative myocardial perfusion from static cardiac and dynamic arterial CT

    Science.gov (United States)

    Bindschadler, Michael; Branch, Kelley R.; Alessio, Adam M.

    2018-05-01

    Quantitative myocardial blood flow (MBF) estimation by dynamic contrast enhanced cardiac computed tomography (CT) requires multi-frame acquisition of contrast transit through the blood pool and myocardium to inform the arterial input and tissue response functions. Both the input and the tissue response functions for the entire myocardium are sampled with each acquisition. However, the long breath holds and frequent sampling can result in significant motion artifacts and relatively high radiation dose. To address these limitations, we propose and evaluate a new static cardiac and dynamic arterial (SCDA) quantitative MBF approach where (1) the input function is well sampled using either prediction from pre-scan timing bolus data or measured from dynamic thin slice ‘bolus tracking’ acquisitions, and (2) the whole-heart tissue response data is limited to one contrast enhanced CT acquisition. A perfusion model uses the dynamic arterial input function to generate a family of possible myocardial contrast enhancement curves corresponding to a range of MBF values. Combined with the timing of the single whole-heart acquisition, these curves generate a lookup table relating myocardial contrast enhancement to quantitative MBF. We tested the SCDA approach in 28 patients that underwent a full dynamic CT protocol both at rest and vasodilator stress conditions. Using measured input function plus single (enhanced CT only) or plus double (enhanced and contrast free baseline CT’s) myocardial acquisitions yielded MBF estimates with root mean square (RMS) error of 1.2 ml/min/g and 0.35 ml/min/g, and radiation dose reductions of 90% and 83%, respectively. The prediction of the input function based on timing bolus data and the static acquisition had an RMS error compared to the measured input function of 26.0% which led to MBF estimation errors greater than threefold higher than using the measured input function. SCDA presents a new, simplified approach for quantitative

  1. Analysis of Partial Volume Effects on Arterial Input Functions Using Gradient Echo: A Simulation Study

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Mikkelsen, Irene Klærke; Pedersen, Michael

    2009-01-01

    of an AIF voxel including the relaxation properties of blood and tissue. Artery orientations parallel and perpendicular to the main magnetic field were investigated and AIF voxels were modeled to either include or be situated close to a large artery. The impact of partial volume effects on quantitative...... perfusion metrics was investigated for the gradient echo pulse sequence at 1.5 T and 3.0 T. It is shown that the tissue contribution broadens and introduces fluctuations in the AIF. Furthermore, partial volume effects bias perfusion metrics in a nonlinear fashion, compromising quantitative perfusion...

  2. Ovarian function after uterine artery embolisation

    African Journals Online (AJOL)

    2009-08-05

    Aug 5, 2009 ... Objective. To evaluate ovarian function in 29 patients who underwent uterine artery embolisation ... of FSH levels, kidney function, blood count and clotting time. .... Funding: Departmental funds and routine services in hospital;.

  3. IMPROVED DERIVATION OF INPUT FUNCTION IN DYNAMIC MOUSE [18F]FDG PET USING BLADDER RADIOACTIVITY KINETICS

    Science.gov (United States)

    Wong, Koon-Pong; Zhang, Xiaoli; Huang, Sung-Cheng

    2013-01-01

    Purpose Accurate determination of the plasma input function (IF) is essential for absolute quantification of physiological parameters in positron emission tomography (PET). However, it requires an invasive and tedious procedure of arterial blood sampling that is challenging in mice because of the limited blood volume. In this study, a hybrid modeling approach is proposed to estimate the plasma IF of 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) in mice using accumulated radioactivity in urinary bladder together with a single late-time blood sample measurement. Methods Dynamic PET scans were performed on nine isoflurane-anesthetized male C57BL/6 mice after a bolus injection of [18F]FDG at the lateral caudal vein. During a 60- or 90-min scan, serial blood samples were taken from the femoral artery. Image data were reconstructed using filtered backprojection with CT-based attenuation correction. Total accumulated radioactivity in the urinary bladder was fitted to a renal compartmental model with the last blood sample and a 1-exponential function that described the [18F]FDG clearance in blood. Multiple late-time blood sample estimates were calculated by the blood [18F]FDG clearance equation. A sum of 4-exponentials was assumed for the plasma IF that served as a forcing function to all tissues. The estimated plasma IF was obtained by simultaneously fitting the [18F]FDG model to the time-activity curves (TACs) of liver and muscle and the forcing function to early (0–1 min) left-ventricle data (corrected for delay, dispersion, partial-volume effects and erythrocytes uptake) and the late-time blood estimates. Using only the blood sample acquired at the end of the study to estimate the IF and the use of liver TAC as an alternative IF were also investigated. Results The area under the plasma TACs calculated for all studies using the hybrid approach was not significantly different from that using all blood samples. [18F]FDG uptake constants in brain, myocardium, skeletal

  4. GPER Mediates Functional Endothelial Aging in Renal Arteries.

    Science.gov (United States)

    Meyer, Matthias R; Rosemann, Thomas; Barton, Matthias; Prossnitz, Eric R

    2017-01-01

    Aging is associated with impaired renal artery function, which is partly characterized by arterial stiffening and a reduced vasodilatory capacity due to excessive generation of reactive oxygen species by NADPH oxidases (Nox). The abundance and activity of Nox depends on basal activity of the heptahelical transmembrane receptor GPER; however, whether GPER contributes to age-dependent functional changes in renal arteries is unknown. This study investigated the effect of aging and Nox activity on renal artery tone in wild-type and GPER-deficient (Gper-/-) mice (4 and 24 months old). In wild-type mice, aging markedly impaired endothelium-dependent, nitric oxide (NO)-mediated relaxations to acetylcholine, which were largely preserved in renal arteries of aged Gper-/- mice. The Nox inhibitor gp91ds-tat abolished this difference by greatly enhancing relaxations in wild-type mice, while having no effect in Gper-/- mice. Contractions to angiotensin II and phenylephrine in wild-type mice were partly sensitive to gp91ds-tat but unaffected by aging. Again, deletion of GPER abolished effects of Nox inhibition on contractile responses. In conclusion, basal activity of GPER is required for the age-dependent impairment of endothelium-dependent, NO-mediated relaxation in the renal artery. Restoration of relaxation by a Nox inhibitor in aged wild-type but not Gper-/- mice strongly supports a role for Nox-derived reactive oxygen species as the underlying cause. Pharmacological blockers of GPER signaling may thus be suitable to inhibit functional endothelial aging of renal arteries by reducing Nox-derived oxidative stress and, possibly, the associated age-dependent deterioration of kidney function. © 2017 S. Karger AG, Basel.

  5. Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (I): Theory, method, and phantom experiments.

    Science.gov (United States)

    van Schie, Jeroen J N; Lavini, Cristina; van Vliet, Lucas J; Vos, Frans M

    2018-05-01

    The arterial input function (AIF) represents the time-dependent arterial contrast agent (CA) concentration that is used in pharmacokinetic modeling. To develop a novel method for estimating the AIF from dynamic contrast-enhanced (DCE-) MRI data, while compensating for flow enhancement. Signal simulation and phantom measurements. Time-intensity curves (TICs) were simulated for different numbers of excitation pulses modeling flow effects. A phantom experiment was performed in which a solution (without CA) was passed through a straight tube, at constant flow velocity. Dynamic fast spoiled gradient echo (FSPGRs) at 3T MRI, both in the simulations and in the phantom experiment. TICs were generated for a duration of 373 seconds and sampled at intervals of 1.247 seconds (300 timepoints). The proposed method first estimates the number of pulses that spins have received, and then uses this knowledge to accurately estimate the CA concentration. The difference between the median of the estimated number of pulses and the true value was determined, as well as the interquartile range (IQR) of the estimations. The estimated CA concentrations were evaluated in the same way. The estimated number of pulses was also used to calculate flow velocity. The difference between the median estimated and reference number of pulses varied from -0.005 to -1.371 (corresponding IQRs: 0.853 and 48.377) at true values of 10 and 180 pulses, respectively. The difference between the median estimated CA concentration and the reference value varied from -0.00015 to 0.00306 mmol/L (corresponding IQRs: 0.01989 and 1.51013 mmol/L) at true values of 0.5 and 8.0 mmol/l, respectively, at an intermediate value of 100 pulses. The estimated flow velocities in the phantom were within 10% of the reference value. The proposed method accurately corrects the MRI signal affected by the inflow effect. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1190-1196. © 2017 International Society for Magnetic

  6. Bronchial arteries: anatomy, function, hypertrophy, and anomalies.

    Science.gov (United States)

    Walker, Christopher M; Rosado-de-Christenson, Melissa L; Martínez-Jiménez, Santiago; Kunin, Jeffrey R; Wible, Brandt C

    2015-01-01

    The two main sources of blood supply to the lungs and their supporting structures are the pulmonary and bronchial arteries. The bronchial arteries account for 1% of the cardiac output but can be recruited to provide additional systemic circulation to the lungs in various acquired and congenital thoracic disorders. An understanding of bronchial artery anatomy and function is important in the identification of bronchial artery dilatation and anomalies and the formulation of an appropriate differential diagnosis. Visualization of dilated bronchial arteries at imaging should alert the radiologist to obstructive disorders that affect the pulmonary circulation and prompt the exclusion of diseases that produce or are associated with pulmonary artery obstruction, including chronic infectious and/or inflammatory processes, chronic thromboembolic disease, and congenital anomalies of the thorax (eg, proximal interruption of the pulmonary artery). Conotruncal abnormalities, such as pulmonary atresia with ventricular septal defect, are associated with systemic pulmonary supply provided by aortic branches known as major aortopulmonary collaterals, which originate in the region of the bronchial arteries. Bronchial artery malformation is a rare left-to-right or left-to-left shunt characterized by an anomalous connection between a bronchial artery and a pulmonary artery or a pulmonary vein, respectively. Bronchial artery interventions can be used successfully in the treatment of hemoptysis, with a low risk of adverse events. Multidetector computed tomography helps provide a vascular road map for the interventional radiologist before bronchial artery embolization. RSNA, 2015

  7. Dll4-Notch signaling determines the formation of native arterial collateral networks and arterial function in mouse ischemia models.

    Science.gov (United States)

    Cristofaro, Brunella; Shi, Yu; Faria, Marcella; Suchting, Steven; Leroyer, Aurelie S; Trindade, Alexandre; Duarte, Antonio; Zovein, Ann C; Iruela-Arispe, M Luisa; Nih, Lina R; Kubis, Nathalie; Henrion, Daniel; Loufrani, Laurent; Todiras, Mihail; Schleifenbaum, Johanna; Gollasch, Maik; Zhuang, Zhen W; Simons, Michael; Eichmann, Anne; le Noble, Ferdinand

    2013-04-01

    Arteriogenesis requires growth of pre-existing arteriolar collateral networks and determines clinical outcome in arterial occlusive diseases. Factors responsible for the development of arteriolar collateral networks are poorly understood. The Notch ligand Delta-like 4 (Dll4) promotes arterial differentiation and restricts vessel branching. We hypothesized that Dll4 may act as a genetic determinant of collateral arterial networks and functional recovery in stroke and hind limb ischemia models in mice. Genetic loss- and gain-of-function approaches in mice showed that Dll4-Notch signaling restricts pial collateral artery formation by modulating arterial branching morphogenesis during embryogenesis. Adult Dll4(+/-) mice showed increased pial collateral numbers, but stroke volume upon middle cerebral artery occlusion was not reduced compared with wild-type littermates. Likewise, Dll4(+/-) mice showed reduced blood flow conductance after femoral artery occlusion, and, despite markedly increased angiogenesis, tissue ischemia was more severe. In peripheral arteries, loss of Dll4 adversely affected excitation-contraction coupling in arterial smooth muscle in response to vasopressor agents and arterial vessel wall adaption in response to increases in blood flow, collectively contributing to reduced flow reserve. We conclude that Dll4-Notch signaling modulates native collateral formation by acting on vascular branching morphogenesis during embryogenesis. Dll4 furthermore affects tissue perfusion by acting on arterial function and structure. Loss of Dll4 stimulates collateral formation and angiogenesis, but in the context of ischemic diseases such beneficial effects are overruled by adverse functional changes, demonstrating that ischemic recovery is not solely determined by collateral number but rather by vessel functionality.

  8. Dll4-Notch signaling determines the formation of native arterial collateral networks and arterial function in mouse ischemia models

    Science.gov (United States)

    Cristofaro, Brunella; Shi, Yu; Faria, Marcella; Suchting, Steven; Leroyer, Aurelie S.; Trindade, Alexandre; Duarte, Antonio; Zovein, Ann C.; Iruela-Arispe, M. Luisa; Nih, Lina R.; Kubis, Nathalie; Henrion, Daniel; Loufrani, Laurent; Todiras, Mihail; Schleifenbaum, Johanna; Gollasch, Maik; Zhuang, Zhen W.; Simons, Michael; Eichmann, Anne; le Noble, Ferdinand

    2013-01-01

    Arteriogenesis requires growth of pre-existing arteriolar collateral networks and determines clinical outcome in arterial occlusive diseases. Factors responsible for the development of arteriolar collateral networks are poorly understood. The Notch ligand Delta-like 4 (Dll4) promotes arterial differentiation and restricts vessel branching. We hypothesized that Dll4 may act as a genetic determinant of collateral arterial networks and functional recovery in stroke and hind limb ischemia models in mice. Genetic loss- and gain-of-function approaches in mice showed that Dll4-Notch signaling restricts pial collateral artery formation by modulating arterial branching morphogenesis during embryogenesis. Adult Dll4+/- mice showed increased pial collateral numbers, but stroke volume upon middle cerebral artery occlusion was not reduced compared with wild-type littermates. Likewise, Dll4+/- mice showed reduced blood flow conductance after femoral artery occlusion, and, despite markedly increased angiogenesis, tissue ischemia was more severe. In peripheral arteries, loss of Dll4 adversely affected excitation-contraction coupling in arterial smooth muscle in response to vasopressor agents and arterial vessel wall adaption in response to increases in blood flow, collectively contributing to reduced flow reserve. We conclude that Dll4-Notch signaling modulates native collateral formation by acting on vascular branching morphogenesis during embryogenesis. Dll4 furthermore affects tissue perfusion by acting on arterial function and structure. Loss of Dll4 stimulates collateral formation and angiogenesis, but in the context of ischemic diseases such beneficial effects are overruled by adverse functional changes, demonstrating that ischemic recovery is not solely determined by collateral number but rather by vessel functionality. PMID:23533173

  9. Arterial stiffness and functional outcome in acute ischemic stroke.

    Science.gov (United States)

    Lee, Yeong-Bae; Park, Joo-Hwan; Kim, Eunja; Kang, Chang-Ki; Park, Hyeon-Mi

    2014-03-01

    Arterial stiffness is a common change associated with aging and can be evaluated by measuring pulse wave velocity (PWV) between sites in the arterial tree, with the stiffer artery having the higher PWV. Arterial stiffness is associated with the risk of stroke in the general population and of fatal stroke in hypertensive patients. This study is to clarify whether PWV value predicts functional outcome of acute ischemic stroke. ONE HUNDRED PATIENTS WERE ENROLLED WITH A DIAGNOSIS OF ACUTE ISCHEMIC STROKE AND CATEGORIZED INTO TWO GROUPS: large-artery atherosclerosis (LAAS) or small vessel disease (SVD) subtype of Trial of Org 10172 in Acute Stroke Treatment (TOAST) classification. Each group was divided into two sub-groups based on the functional outcome of acute ischemic stroke, indicated by modified Rankin Scale (mRS) at discharge. Poor functional outcome group was defined as a mRS ≥ 3 at discharge. Student's t-test or Mann-Whitney U-test were used to compare maximal brachial-ankle PWV (baPWV) values. Twenty-four patients whose state was inadequate to assess baPWV or mRS were excluded. There were 38 patients with good functional outcome (mRS vs. 1,789.80 ± 421.91, p = 0.022), while there was no significant difference of baPWV among patients with LAAS subtype (2,071.76 ± 618.42 vs. 1,878.00 ± 365.35, p = 0.579). Arterial stiffness indicated by baPWV is associated with the functional outcome of acute ischemic stroke. This finding suggests that measurement of baPWV predicts functional outcome in patients with stroke especially those whose TOAST classification was confirmed as SVD subtype.

  10. Cone pathway function in relation to asymmetric carotid artery stenosis

    DEFF Research Database (Denmark)

    Kofoed, Peter Kristian; Munch, Inger Christine; Holfort, Stig K

    2013-01-01

    Purpose:  To examine retinal function in relation to retinal perfusion pressure in patients with carotid artery stenosis. Methods:  Thirteen patients with carotid artery stenosis without clinical eye disease underwent assessment of ophthalmic artery systolic blood pressure (OSP) by ocular...... pneumoplethysmography, carotid artery obstructive disease by ultrasonography, intraocular pressure by applanation tonometry, retinal perfusion by fluorescein angiography and retinal function by multifocal electroretinography (mfERG). Data analysis compared the eye on the most stenotic side with the fellow eye...... pressure (p = 0.0028, 0.011, 0.041 for N1, P1, N2 implicit times, respectively, and p = 0.0086, 0.016, 0.040 for N1, P1, N2 for amplitudes, respectively, corrected for OSP). Conclusion:  Cone function deviation was observed in clinically healthy eyes on the side with highest degree of carotid artery...

  11. Global sensitivity analysis of computer models with functional inputs

    International Nuclear Information System (INIS)

    Iooss, Bertrand; Ribatet, Mathieu

    2009-01-01

    Global sensitivity analysis is used to quantify the influence of uncertain model inputs on the response variability of a numerical model. The common quantitative methods are appropriate with computer codes having scalar model inputs. This paper aims at illustrating different variance-based sensitivity analysis techniques, based on the so-called Sobol's indices, when some model inputs are functional, such as stochastic processes or random spatial fields. In this work, we focus on large cpu time computer codes which need a preliminary metamodeling step before performing the sensitivity analysis. We propose the use of the joint modeling approach, i.e., modeling simultaneously the mean and the dispersion of the code outputs using two interlinked generalized linear models (GLMs) or generalized additive models (GAMs). The 'mean model' allows to estimate the sensitivity indices of each scalar model inputs, while the 'dispersion model' allows to derive the total sensitivity index of the functional model inputs. The proposed approach is compared to some classical sensitivity analysis methodologies on an analytical function. Lastly, the new methodology is applied to an industrial computer code that simulates the nuclear fuel irradiation.

  12. Arterial Stiffness and Functional Outcome in Acute Ischemic Stroke

    OpenAIRE

    Lee, Yeong-Bae; Park, Joo-Hwan; Kim, Eunja; Kang, Chang-Ki; Park, Hyeon-Mi

    2014-01-01

    Objective Arterial stiffness is a common change associated with aging and can be evaluated by measuring pulse wave velocity (PWV) between sites in the arterial tree, with the stiffer artery having the higher PWV. Arterial stiffness is associated with the risk of stroke in the general population and of fatal stroke in hypertensive patients. This study is to clarify whether PWV value predicts functional outcome of acute ischemic stroke. Methods One hundred patients were enrolled with a diagnosi...

  13. Effect of parallel radiofrequency transmission on arterial input function selection in dynamic contrast-enhanced 3 Tesla pelvic MRI.

    Science.gov (United States)

    Chafi, Hatim; Elias, Saba N; Nguyen, Huyen T; Friel, Harry T; Knopp, Michael V; Guo, BeiBei; Heymsfield, Steven B; Jia, Guang

    2016-01-01

    To evaluate whether parallel radiofrequency transmission (mTX) can improve the symmetry of the left and right femoral arteries in dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) of prostate and bladder cancer. Eighteen prostate and 24 bladder cancer patients underwent 3.0 Tesla DCE-MRI scan with a single transmission channel coil. Subsequently, 21 prostate and 21 bladder cancer patients were scanned using the dual channel mTX upgrade. The precontrast signal ( S0) and the maximum enhancement ratio (MER) were measured in both the left and the right femoral arteries. Within the patient cohort, the ratio of S0 and MER in the left artery to that in the right artery ( S0_LR, MER_LR) was calculated with and without the use of mTX. Left to right asymmetry indices for S0 ( S0_LRasym) and MER ( MER_LRasym) were defined as the absolute values of the difference between S0_LR and 1, and the difference between MER_LR and 1, respectively. S0_LRasym, and MER_LRasym were 0.21 and 0.19 for prostate cancer patients with mTX, and 0.43 and 0.45 for the ones imaged without it (P enhancement. © 2015 Wiley Periodicals, Inc.

  14. Modelling of Multi Input Transfer Function for Rainfall Forecasting in Batu City

    OpenAIRE

    Priska Arindya Purnama

    2017-01-01

    The aim of this research is to model and forecast the rainfall in Batu City using multi input transfer function model based on air temperature, humidity, wind speed and cloud. Transfer function model is a multivariate time series model which consists of an output series (Yt) sequence expected to be effected by an input series (Xt) and other inputs in a group called a noise series (Nt). Multi input transfer function model obtained is (b1,s1,r1) (b2,s2,r2) (b3,s3,r3) (b4,s4,r4)(pn,qn) = (0,0,0)...

  15. Sequential designs for sensitivity analysis of functional inputs in computer experiments

    International Nuclear Information System (INIS)

    Fruth, J.; Roustant, O.; Kuhnt, S.

    2015-01-01

    Computer experiments are nowadays commonly used to analyze industrial processes aiming at achieving a wanted outcome. Sensitivity analysis plays an important role in exploring the actual impact of adjustable parameters on the response variable. In this work we focus on sensitivity analysis of a scalar-valued output of a time-consuming computer code depending on scalar and functional input parameters. We investigate a sequential methodology, based on piecewise constant functions and sequential bifurcation, which is both economical and fully interpretable. The new approach is applied to a sheet metal forming problem in three sequential steps, resulting in new insights into the behavior of the forming process over time. - Highlights: • Sensitivity analysis method for functional and scalar inputs is presented. • We focus on the discovery of most influential parts of the functional domain. • We investigate economical sequential methodology based on piecewise constant functions. • Normalized sensitivity indices are introduced and investigated theoretically. • Successful application to sheet metal forming on two functional inputs

  16. Modelling of Multi Input Transfer Function for Rainfall Forecasting in Batu City

    Directory of Open Access Journals (Sweden)

    Priska Arindya Purnama

    2017-11-01

    Full Text Available The aim of this research is to model and forecast the rainfall in Batu City using multi input transfer function model based on air temperature, humidity, wind speed and cloud. Transfer function model is a multivariate time series model which consists of an output series (Yt sequence expected to be effected by an input series (Xt and other inputs in a group called a noise series (Nt. Multi input transfer function model obtained is (b1,s1,r1 (b2,s2,r2 (b3,s3,r3 (b4,s4,r4(pn,qn = (0,0,0 (23,0,0 (1,2,0 (0,0,0 ([5,8],2 and shows that air temperature on t-day affects rainfall on t-day, rainfall on t-day is influenced by air humidity in the previous 23 days, rainfall on t-day is affected by wind speed in the previous day , and rainfall on day t is affected by clouds on day t. The results of rainfall forecasting in Batu City with multi input transfer function model can be said to be accurate, because it produces relatively small RMSE value. The value of RMSE data forecasting training is 7.7921 while forecasting data testing is 4.2184. Multi-input transfer function model is suitable for rainfall in Batu City.

  17. [Changes of brain function and cognitive function after carotid artery stenting].

    Science.gov (United States)

    Lu, Z X; Deng, G; Wei, H L; Zhao, G F; Wen, L Z; Chen, X

    2017-10-24

    Objective: To investigate the effect of carotid artery stenting(CAS) on cognitive function and brain function based on changes of a battery of neuropsychological tests and magnetic resonance imaging. Methods: Thirty-three patients were included with 17 in the stent-placement group and 16 in the control group (receiving medical treatment), among whom, the unilateral or bilateral severe internal carotid artery stenosis was confirmed by cerebral vascular angiography in the department of Interventional Radiology and Vascular Surgery of Zhongda Hospital Southeast University from June 2015 to September 2016.Neuropsychological tests and rest-state blood oxygenation level dependent fMRI were performed at the baseline and six months follow-up.The baseline characteristics and follow-up changes were compared in each group. Results: The overall cognitive function of the stent-placement group was statistically significantly improved ( P function, memory, attention and other aspects.The value of amplitude of low-frequency fluctuation(ALFF) showed statistically significant increase ( P left prefrontal cortex ( t =5.861 3, P left superior parietal lobe( t =5.601 2, P left retrosplenial cingulate cortex( t =-5.590 4, P left insular cortex ( t =-6.340 8, P right insular cortex ( t =-8.129 9, P left dorsal anterior cingulate cortex ( t =-5.584 8, P 0.05, Alphasim correction)between baseline and follow-up results in control group.Besides, the ALFF changes of the left insular cortex ( r =-0.591, P =0.033) and bilateral motor cortical area ( r =-0.659, P =0.014) were negatively correlated with auditory verb learning test (AVLT) score changes.The ALFF change of bilateral motor cortical area was negatively correlated with the AVLT-delay score change ( r =-0.588, P =0.034). And the ALFF change on right insular cortex and the frontal assessment battery (FAB) score change was positively correlated ( r =0.638, P =0.025). Conclusions: The overall cognitive function of patients with carotid

  18. Quantifying dynamic contrast-enhanced MRI of the knee in children with juvenile rheumatoid arthritis using an arterial input function (AIF) extracted from popliteal artery enhancement, and the effect of the choice of the AIF on the kinetic parameters.

    Science.gov (United States)

    Workie, Dagnachew W; Dardzinski, Bernard J

    2005-09-01

    Quantification of dynamic contrast-enhanced (DCE) MRI based on pharmacokinetic modeling requires specification of the arterial input function (AIF). A full representation of the plasma concentration data, including the initial rise and decay parts, considering the delay and dispersion of the bolus contrast is important. This work deals with modeling of DCE-MRI data from the knees of children with a history of juvenile rheumatoid arthritis (JRA) by using an AIF extracted from the signal enhancement data from the nearby popliteal artery. Three models for the AIFs were considered: a triexponential (AIF1), a gamma-variate plus a biexponential (AIF2), and a biexponential (AIF3). The pharmacokinetic parameters obtained from the model were Ktrans', kep, and V'p. The results from AIF1 and AIF2 showed no statistically significant difference. However, some statistically significant differences were seen with AIF3, particularly for parameters Ktrans' and V'p in the synovium (SNVM). These results suggest the importance of obtaining an appropriate AIF representation in pharmacokinetic modeling of JRA. Specifically, the initial rising part of the AIF should be incorporated for optimal pharmacokinetic modeling results. The pharmacokinetic parameters (mean+/-SD) derived from AIF1, using the average plasma concentration data, were as follows: SNVM Ktrans'(min-1)=0.52+/-0.34, kep(min-1)=0.71+/-0.39, and V'p=0.33+/-0.16, and for the distal femoral physis (DFP) Ktrans'(min-1)=1.83+/-1.78, kep(min-1)=2.65+/-1.80, and V'p=0.46+/-0.31. The pharmacokinetic parameters in the SNVM may be useful for investigating activity and therapeutic efficacy in studies of JRA. Longitudinal studies are necessary to find or demonstrate the parameter that is more sensitive to disease activity. Copyright (c) 2005 Wiley-Liss, Inc.

  19. Image-derived input function in dynamic human PET/CT: methodology and validation with 11C-acetate and 18F-fluorothioheptadecanoic acid in muscle and 18F-fluorodeoxyglucose in brain

    International Nuclear Information System (INIS)

    Croteau, Etienne; Lavallee, Eric; Hubert, Laurent; Rousseau, Jacques A.; Lecomte, Roger; Labbe, Sebastien M.; Carpentier, Andre C.; Pifferi, Fabien; Cunnane, Stephen C.; Benard, Francois

    2010-01-01

    Despite current advances in PET/CT systems, blood sampling still remains the standard method to obtain the radiotracer input function for tracer kinetic modelling. The purpose of this study was to validate the use of image-derived input functions (IDIF) of the carotid and femoral arteries to measure the arterial input function (AIF) in PET imaging. The data were obtained from two different research studies, one using 18 F-FDG for brain imaging and the other using 11 C-acetate and 18 F-fluoro-6-thioheptadecanoic acid ( 18 F-FTHA) in femoral muscles. The method was validated with two phantom systems. First, a static phantom consisting of syringes of different diameters containing radioactivity was used to determine the recovery coefficient (RC) and spill-in factors. Second, a dynamic phantom built to model bolus injection and clearance of tracers was used to establish the correlation between blood sampling, AIF and IDIF. The RC was then applied to the femoral artery data from PET imaging studies with 11 C-acetate and 18 F-FTHA and to carotid artery data from brain imaging with 18 F-FDG. These IDIF data were then compared to actual AIFs from patients. With 11 C-acetate, the perfusion index in the femoral muscle was 0.34±0.18 min -1 when estimated from the actual time-activity blood curve, 0.29±0.15 min -1 when estimated from the corrected IDIF, and 0.66±0.41 min -1 when the IDIF data were not corrected for RC. A one-way repeated measures (ANOVA) and Tukey's test showed a statistically significant difference for the IDIF not corrected for RC (p 18 F-FTHA there was a strong correlation between Patlak slopes, the plasma to tissue transfer rate calculated using the true plasma radioactivity content and the corrected IDIF for the femoral muscles (vastus lateralis r=0.86, p=0.027; biceps femoris r=0.90, p=0.017). On the other hand, there was no correlation between the values derived using the AIF and those derived using the uncorrected IDIF. Finally, in the brain imaging

  20. Peritumoral Artery Scoring System: a Novel Scoring System to Predict Renal Function Outcome after Laparoscopic Partial Nephrectomy.

    Science.gov (United States)

    Zhang, Ruiyun; Wu, Guangyu; Huang, Jiwei; Shi, Oumin; Kong, Wen; Chen, Yonghui; Xu, Jianrong; Xue, Wei; Zhang, Jin; Huang, Yiran

    2017-06-06

    The present study aimed to assess the impact of peritumoral artery characteristics on renal function outcome prediction using a novel Peritumoral Artery Scoring System based on computed tomography arteriography. Peritumoral artery characteristics and renal function were evaluated in 220 patients who underwent laparoscopic partial nephrectomy and then validate in 51 patients with split and total glomerular filtration rate (GFR). In particular, peritumoral artery classification and diameter were measured to assign arteries into low, moderate, and high Peritumoral Artery Scoring System risk categories. Univariable and multivariable logistic regression analyses were then used to determine risk factors for major renal functional decline. The Peritumoral Artery Scoring System and four other nephrometry systems were compared using receiver operating characteristic curve analysis. The Peritumoral Artery Scoring System was significantly superior to the other systems for predicting postoperative renal function decline (p system was a superior independent predictor of estimated glomerular filtration rate (eGFR) decline (area-under-the-curve = 0.865, p renal function outcome after laparoscopic partial nephrectomy.

  1. Arterial stiffness and wave reflection: sex differences and relationship with left ventricular diastolic function.

    Science.gov (United States)

    Russo, Cesare; Jin, Zhezhen; Palmieri, Vittorio; Homma, Shunichi; Rundek, Tatjana; Elkind, Mitchell S V; Sacco, Ralph L; Di Tullio, Marco R

    2012-08-01

    Increased arterial stiffness and wave reflection have been reported in heart failure with normal ejection fraction (HFNEF) and in asymptomatic left ventricular (LV) diastolic dysfunction, a precursor of HFNEF. It is unclear whether women, who have higher frequency of HFNEF, are more vulnerable than men to the deleterious effects of arterial stiffness on LV diastolic function. We investigated, in a large community-based cohort, whether sex differences exist in the relationship among arterial stiffness, wave reflection, and LV diastolic function. Arterial stiffness and wave reflection were assessed in 983 participants from the Cardiovascular Abnormalities and Brain Lesions study using applanation tonometry. The central pulse pressure/stroke volume index, total arterial compliance, pulse pressure amplification, and augmentation index were used as parameters of arterial stiffness and wave reflection. LV diastolic function was evaluated by 2-dimensional echocardiography and tissue-Doppler imaging. Arterial stiffness and wave reflection were greater in women compared with men, independent of body size and heart rate (all Pfunction in both sexes. Further adjustment for cardiovascular risk factors attenuated these relationships; however, a higher central pulse pressure/stroke volume index predicted LV diastolic dysfunction in women (odds ratio, 1.54; 95% confidence intervals, 1.03 to 2.30) and men (odds ratio, 2.09; 95% confidence interval, 1.30 to 3.39), independent of other risk factors. In conclusion, in our community-based cohort study, higher arterial stiffness was associated with worse LV diastolic function in men and women. Women's higher arterial stiffness, independent of body size, may contribute to their greater susceptibility to develop HFNEF.

  2. Variance gradients and uncertainty budgets for nonlinear measurement functions with independent inputs

    International Nuclear Information System (INIS)

    Campanelli, Mark; Kacker, Raghu; Kessel, Rüdiger

    2013-01-01

    A novel variance-based measure for global sensitivity analysis, termed a variance gradient (VG), is presented for constructing uncertainty budgets under the Guide to the Expression of Uncertainty in Measurement (GUM) framework for nonlinear measurement functions with independent inputs. The motivation behind VGs is the desire of metrologists to understand which inputs' variance reductions would most effectively reduce the variance of the measurand. VGs are particularly useful when the application of the first supplement to the GUM is indicated because of the inadequacy of measurement function linearization. However, VGs reduce to a commonly understood variance decomposition in the case of a linear(ized) measurement function with independent inputs for which the original GUM readily applies. The usefulness of VGs is illustrated by application to an example from the first supplement to the GUM, as well as to the benchmark Ishigami function. A comparison of VGs to other available sensitivity measures is made. (paper)

  3. Chronic hindlimb ischemia impairs functional vasodilation and vascular reactivity in mouse feed arteries

    Directory of Open Access Journals (Sweden)

    Trevor R Cardinal

    2011-12-01

    Full Text Available Vasodilation of lower leg arterioles is impaired in animal models of chronic peripheral ischemia. In addition to arterioles, feed arteries are a critical component of the vascular resistance network, accounting for as much as 50% of the pressure drop across the arterial circulation. Despite the critical importance of feed arteries in blood flow control, the impact of ischemia on feed artery vascular reactivity is unknown. At 14 days following unilateral resection of the femoral-saphenous artery-vein pair, functional vasodilation of the profunda femoris artery was severely impaired, 11 ± 9% versus 152 ± 22%. Although endothelial and smooth muscle-dependent vasodilation were both impaired in ischemic arteries compared to control arteries (Ach: 40 ± 14% vs 81 ± 11%, SNP: 43 ± 12% vs and 85 ± 11%, the responses to acetylcholine and sodium nitroprusside were similar, implicating impaired smooth muscle-dependent vasodilation. Conversely, vasoconstriction responses to norepinephrine were not different between ischemic and control arteries, -68 ± 3% versus -66 ± 3%, indicating that smooth muscle cells were functional following the ischemic insult. Finally, maximal dilation responses to acetylcholine, in vitro, were significantly impaired in the ischemic artery compared to control, 71 ± 9% versus 97 ± 2%, despite a similar generation of myogenic tone to the same intravascular pressure (80 mmHg. These data indicate that ischemia impairs feed artery vasodilation by impairing the vascular wall’s responsiveness to vasodilating stimuli. Future studies to examine the mechanistic basis for these observations or treatment strategies to improve feed artery vasodilation following ischemia could provide the foundation for an alternative therapeutic paradigm for peripheral arterial occlusive disease.

  4. Functional effects of renal artery stent placement on treated and contralateral kidneys.

    NARCIS (Netherlands)

    Leertouwer, T.C.; Derkx, F.H.M.; Pattynama, P.M.; Deinum, J.; Dijk, L.C. van; Schalekamp, M.A.D.H.

    2002-01-01

    BACKGROUND: This study examined the effects of stent placement for renal artery stenosis on the function of treated and contralateral kidneys. METHODS: Eighteen patients who underwent stent placement for unilateral renal artery stenosis presenting with hypertension and/or renal failure were studied

  5. Impact of arterial input function selection on the accuracy of dynamic contrast-enhanced MRI quantitative analysis for the diagnosis of clinically significant prostate cancer.

    Science.gov (United States)

    Azahaf, Mustapha; Haberley, Marc; Betrouni, Nacim; Ernst, Olivier; Behal, Hélène; Duhamel, Alain; Ouzzane, Adil; Puech, Philippe

    2016-03-01

    Using a limited temporal resolution dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) dataset to assess the impact of the arterial input function (AIF) choice on the transfer constant (K(trans) ) to distinguish prostate carcinoma (PCa) from benign tissue. Thirty-eight patients with clinically important peripheral PCa (≥0.5 cc) were retrospectively studied. These patients underwent 1.5T multiparametric prostate MR with PCa and benign regions of interest (ROIs) selected using a visual registration with morphometric reconstruction obtained from radical prostatectomy. Using three pharmacokinetic (PK) analysis software programs, the mean K(trans) of ROIs was computed using three AIFs: an individual AIF (Ind-AIF) and two literature population average AIFs of Weinmann (W-AIF) and of Fritz-Hansen (FH-AIF). A pairwise comparison of the area under the receiver operating characteristic curves (AUROCC) obtained with different AIFs was performed. AUROCCs obtained with W-AIF (ranging from 0.801 to 0.843) were significantly higher than FH-AIF (ranging from 0.698 to 0.780, 0.002 ≤ P ≤ 0.045) and similar to or higher than Ind-AIF (ranging from 0.591 to 0.839, 0.014 ≤ P ≤ 0.9). Ind-AIF and FH-AIF provided similar AUROCC (0.34 ≤ P ≤ 0.81). The pairwise correlation of K(trans) values was moderate to very strong when comparing W-AIF with FH-AIF (the Spearman's correlation coefficients [SCCs] ranged from 0.55 to 0.93) and very weak to moderate when comparing W-AIF with Ind-AIF (the SCCs ranged from 0.018 to 0.59) or FH-AIF with Ind-AIF (the SCCs ranged from 0.30 to 0.51). W-AIF yielded a higher performance than FH-AIF and a similar or higher performance than Ind-AIF in distinguishing PCa from benign tissue. © 2015 Wiley Periodicals, Inc.

  6. Morphology and function of dog arterial grafts preserved in UW-solution

    NARCIS (Netherlands)

    Vischjager, M.; van Gulik, T. M.; Pfaffendorf, M.; van Zwieten, P. A.; van Marle, J.; Kromhout, J. G.; Klopper, P. J.; Jacobs, M. J.

    1995-01-01

    To assess the function of arterial grafts after prolonged preservation in the University of Wisconsin solution (UW), in vitro and in vivo. Carotid arteries were harvested from dogs and stored for 1-21 days at 4 degrees C in UW (n = 10) or in PBS (0.9% NaCl, pH 7.4), (PBS) (n = 10). Slices were

  7. Effect of dark chocolate on arterial function in healthy individuals.

    Science.gov (United States)

    Vlachopoulos, Charalambos; Aznaouridis, Konstantinos; Alexopoulos, Nikolaos; Economou, Emmanuel; Andreadou, Ioanna; Stefanadis, Christodoulos

    2005-06-01

    Epidemiologic studies suggest that high flavonoid intake confers a benefit on cardiovascular outcome. Endothelial function, arterial stiffness, and wave reflections are important determinants of cardiovascular performance and are predictors of cardiovascular risk. The effect of flavonoid-rich dark chocolate (100 g) on endothelial function, aortic stiffness, wave reflections, and oxidant status were studied for 3 h in 17 young healthy volunteers according to a randomized, single-blind, sham procedure-controlled, cross-over protocol. Flow-mediated dilation (FMD) of the brachial artery, aortic augmentation index (AIx), and carotid-femoral pulse wave velocity (PWV) were used as measures of endothelial function, wave reflections, and aortic stiffness, respectively. Plasma oxidant status was evaluated with measurement of plasma malondialdehyde (MDA) and total antioxidant capacity (TAC). Chocolate led to a significant increase in resting and hyperemic brachial artery diameter throughout the study (maximum increase by 0.15 mm and 0.18 mm, respectively, P chocolate throughout the study (maximum absolute decrease 7.8%, P chocolate, indicating no alterations in plasma oxidant status. Our study shows for the first time that consumption of dark chocolate acutely decreases wave reflections, that it does not affect aortic stiffness, and that it may exert a beneficial effect on endothelial function in healthy adults. Chocolate consumption may exert a protective effect on the cardiovascular system; further studies are warranted to assess any long-term effects.

  8. Effect of dark chocolate on arterial function in healthy individuals: cocoa instead of ambrosia?

    Science.gov (United States)

    Vlachopoulos, Charalambos; Alexopoulos, Nikolaos; Stefanadis, Christodoulos

    2006-06-01

    Cocoa has been consumed for at least 2500 years, and for long time it has been regarded as a medicine. Arterial function is of paramount importance for the proper function and integrity of the cardiovascular system. Dark chocolate and flavonoid-rich cocoa have beneficial acute and short-term effects on endothelial function and wave reflections in normal individuals, in adults with cardiovascular risk factors, and in patients with coronary artery disease. Furthermore, dark chocolate and flavonoid-rich cocoa may have a blood pressure-lowering effect. These effects can be attributed to flavonoids and are mainly mediated through increased nitric oxide bioavailability. Further research is needed to demonstrate whether these effects of chocolate on arterial function are translated into clinical benefit.

  9. Functional assessment of sequential coronary artery fistula and coronary artery stenosis with fractional flow reserve and stress adenosine myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Kuan Leong Yew

    2015-10-01

    Full Text Available Coronary artery fistula is an abnormal connection between one coronary artery to another coronary artery or cardiac chambers. The coronary artery fistula may cause significant shunting of blood and cause “pseudo-stenosis” or “steal phenomenon”. This will also accentuate pre-existing mild-moderate de novo coronary lesions with resultant greater pressure gradient difference across the lesions. Thus, fractional flow reserve can be a useful tool to guide intervention decision on the coronary artery fistula. There are very few published reports regarding the use of FFR to assess coronary artery fistula. In fact, there is no outcome data regarding the deferment of coronary artery fistula intervention when the FFR is not physiologically significant. This case highlighted the use of FFR to evaluate the functional significance of coronary fistula in the setting of ischemia evaluation and it was proven to be safe to defer intervention with good 3 year clinical outcome. Stress adenosine myocardial perfusion imaging correlated with the FFR result.

  10. Assessment of input function distortions on kinetic model parameters in simulated dynamic 82Rb PET perfusion studies

    International Nuclear Information System (INIS)

    Meyer, Carsten; Peligrad, Dragos-Nicolae; Weibrecht, Martin

    2007-01-01

    Cardiac 82 rubidium dynamic PET studies allow quantifying absolute myocardial perfusion by using tracer kinetic modeling. Here, the accurate measurement of the input function, i.e. the tracer concentration in blood plasma, is a major challenge. This measurement is deteriorated by inappropriate temporal sampling, spillover, etc. Such effects may influence the measured input peak value and the measured blood pool clearance. The aim of our study is to evaluate the effect of input function distortions on the myocardial perfusion as estimated by the model. To this end, we simulate noise-free myocardium time activity curves (TACs) with a two-compartment kinetic model. The input function to the model is a generic analytical function. Distortions of this function have been introduced by varying its parameters. Using the distorted input function, the compartment model has been fitted to the simulated myocardium TAC. This analysis has been performed for various sets of model parameters covering a physiologically relevant range. The evaluation shows that ±10% error in the input peak value can easily lead to ±10-25% error in the model parameter K 1 , which relates to myocardial perfusion. Variations in the input function tail are generally less relevant. We conclude that an accurate estimation especially of the plasma input peak is crucial for a reliable kinetic analysis and blood flow estimation

  11. Evaluation of two population-based input functions for quantitative neurological FDG PET studies

    International Nuclear Information System (INIS)

    Eberl, S.; Anayat, A.R.; Fulton, R.R.; Hooper, P.K.; Fulham, M.J.

    1997-01-01

    The conventional measurement of the regional cerebral metabolic rate of glucose (rCMRGlc) with fluorodexoyglucose (FDG) and positron emission tomography (PET) requires arterial or arterialised-venous (a-v) blood sampling at frequent intervals to obtain the plasma input function (IF). We evaluated the accuracy of rCMRGlc measurements using population-based IFs that were calibrated with two a-v blood samples. Population-based IFs were derived from: (1) the average of a-v IFs from 26 patients (Standard IF) and (2) a published model of FDG plasma concentration (Feng IF). Values for rCMRGlc calculated from the population-based IFs were compared with values obtained with IFs derived from frequent a-v blood sampling in 20 non-diabetic and six diabetic patients. Values for rCMRGlc calculated with the different IFs were highly correlated for both patient groups (r≥0.992) and root mean square residuals about the regression line were less than 0.24 mg/min/100 g. The Feng IF tended to underestimate high rCMRGlc. Both population-based IFs simplify the measurement of rCMRGlc with minimal loss in accuracy and require only two a-v blood samples for calibration. The reduced blood sampling requirements markedly reduce radiation exposure to the blood sampler. (orig.)

  12. The cerebral blood flow measurement without absolute input function value for PET O-15 injection method

    International Nuclear Information System (INIS)

    Matsuda, Tadashige

    2004-01-01

    This paper shows the method of the measurement for the region of interest's (ROI's) cerebral blood flow (CBF) using PET data and the input function without the absolute density value of the radio activity. The value of the input function and the output function are fixed from the clinical data by regression analysis. The input function and the output function are transformed by the Fourier transform. The transfer function of the differential equation of the compartment model is got by these Fourier transforms. The CBF can be estimated by the transfer function regression analysis. Results are compared between the proposal and conventional methods. (author)

  13. Exercise training improves endothelial function in resistance arteries of young prehypertensives.

    Science.gov (United States)

    Beck, D T; Martin, J S; Casey, D P; Braith, R W

    2014-05-01

    Prehypertension is associated with reduced conduit artery endothelial function and perturbation of oxidant/antioxidant status. It is unknown whether endothelial dysfunction persists to resistance arteries and whether exercise training affects oxidant/antioxidant balance in young prehypertensives. We examined resistance artery function using venous occlusion plethysmography measurement of forearm (FBF) and calf blood flow (CBF) at rest and during reactive hyperaemia (RH), as well as lipid peroxidation (8-iso-PGF2α) and antioxidant capacity (Trolox-equivalent antioxidant capacity; TEAC) before and after exercise intervention or time control. Forty-three unmedicated prehypertensive and 15 matched normotensive time controls met screening requirements and participated in the study (age: 21.1±0.8 years). Prehypertensive subjects were randomly assigned to resistance exercise training (PHRT; n=15), endurance exercise training (PHET; n=13) or time-control groups (PHTC; n=15). Treatment groups exercised 3 days per week for 8 weeks. Peak and total FBF were lower in prehypertensives than normotensives (12.7±1.2 ml min(-1) per100 ml tissue and 89.1±7.7 ml min(-1) per 100 ml tissue vs 16.3±1.0 ml min(-1) per 100 ml tissue and 123.3±6.4 ml min(-1) per 100 ml tissue, respectively; Pendurance training are effective in improving resistance artery endothelial function and oxidant/antioxidant balance in young prehypertensives.

  14. Effect of tubing length on the dispersion correction of an arterially sampled input function for kinetic modeling in PET.

    Science.gov (United States)

    O'Doherty, Jim; Chilcott, Anna; Dunn, Joel

    2015-11-01

    Arterial sampling with dispersion correction is routinely performed for kinetic analysis of PET studies. Because of the the advent of PET-MRI systems, non-MR safe instrumentation will be required to be kept outside the scan room, which requires the length of the tubing between the patient and detector to increase, thus worsening the effects of dispersion. We examined the effects of dispersion in idealized radioactive blood studies using various lengths of tubing (1.5, 3, and 4.5 m) and applied a well-known transmission-dispersion model to attempt to correct the resulting traces. A simulation study was also carried out to examine noise characteristics of the model. The model was applied to patient traces using a 1.5 m acquisition tubing and extended to its use at 3 m. Satisfactory dispersion correction of the blood traces was achieved in the 1.5 m line. Predictions on the basis of experimental measurements, numerical simulations and noise analysis of resulting traces show that corrections of blood data can also be achieved using the 3 m tubing. The effects of dispersion could not be corrected for the 4.5 m line by the selected transmission-dispersion model. On the basis of our setup, correction of dispersion in arterial sampling tubing up to 3 m by the transmission-dispersion model can be performed. The model could not dispersion correct data acquired using a 4.5 m arterial tubing.

  15. Biomarkers of coagulation, fibrinolysis, endothelial function, and inflammation in arterialized venous blood

    DEFF Research Database (Denmark)

    Gram, Anne Sofie; Skov, Jane; Ploug, Thorkil

    2014-01-01

    Effects of venous blood arterialization on cardiovascular risk markers are still unknown. We evaluated biomarkers of inflammation, coagulation, fibrinolysis, and endothelial function in arterialized compared with regular venous blood. Cubital venipunctures were obtained from 10 healthy volunteers....... Arterialization was generated by 10 min heating of the contralateral hand. Concentrations of albumin, C-reactive protein (CRP), tissue-type plasminogen activator (t-PA), plasminogen activator inhibitor type 1 (PAI-1), and von Willebrand factor (vWF) were measured by validated assays. Concentrations of albumin......, CRP, and vWF were significantly lower in arterialized than in venous blood (albumin: 43.8 g/l and 44.8 g/l, P = 0.02). Differences in CRP and vWF became insignificant after adjusting for albumin. The endogenous thrombin potential (ETP) was significantly higher in arterialized than in venous blood...

  16. Strategies for the generation of parametric images of [11C]PIB with plasma input functions considering discriminations and reproducibility.

    Science.gov (United States)

    Edison, Paul; Brooks, David J; Turkheimer, Federico E; Archer, Hilary A; Hinz, Rainer

    2009-11-01

    Pittsburgh compound B or [11C]PIB is an amyloid imaging agent which shows a clear differentiation between subjects with Alzheimer's disease (AD) and controls. However the observed signal difference in other forms of dementia such as dementia with Lewy bodies (DLB) is smaller, and mild cognitively impaired (MCI) subjects and some healthy elderly normals may show intermediate levels of [11C]PIB binding. The cerebellum, a commonly used reference region for non-specific tracer uptake in [11C]PIB studies in AD may not be valid in Prion disorders or monogenic forms of AD. The aim of this work was to: 1-compare methods for generating parametric maps of [11C]PIB retention in tissue using a plasma input function in respect of their ability to discriminate between AD subjects and controls and 2-estimate the test-retest reproducibility in AD subjects. 12 AD subjects (5 of which underwent a repeat scan within 6 weeks) and 10 control subjects had 90 minute [11C]PIB dynamic PET scans, and arterial plasma input functions were measured. Parametric maps were generated with graphical analysis of reversible binding (Logan plot), irreversible binding (Patlak plot), and spectral analysis. Between group differentiation was calculated using Student's t-test and comparisons between different methods were made using p values. Reproducibility was assessed by intraclass correlation coefficients (ICC). We found that the 75 min value of the impulse response function showed the best group differentiation and had a higher ICC than volume of distribution maps generated from Logan and spectral analysis. Patlak analysis of [11C]PIB binding was the least reproducible.

  17. The study of the value of applying the special functions of DSA during uterine artery embolization

    International Nuclear Information System (INIS)

    Wang Ting; Zhao Zhenhua; Lv Weigong

    2007-01-01

    Objective: To study the value of applying the special functions of DSA during uterine artery embolization. Methods: 122 cases were performed uterine artery embolization, including 67 cases with traditional operation and 55 cases with applying the special functions of DSA: rotary DSA angiography, the best work position and road map technology. We recorded the correlative operative indices to compare and analyse the mean exposure time, the mean operative time, the mean dosage of contrast medium, the probability of vasospasm and injury of blood vessel during operation. Results: The mean exposure time, mean operative time and the mean dosage of contrast medium were reduced with the special functions of DSA during uterine artery embolization. There is significant difference between traditional operation and the operation applying the special functions of DSA (P<0.01). Conclusion: Applying the special functions of DSA during uterine artery embolization can reduce the operative time, operative risk and economic burden. (authors)

  18. Obesity and overweight associated with increased carotid diameter and decreased arterial function in young otherwise healthy men.

    Science.gov (United States)

    Kappus, Rebecca M; Fahs, Christopher A; Smith, Denise; Horn, Gavin P; Agiovlasitis, Stomatis; Rossow, Lindy; Jae, Sae Y; Heffernan, Kevin S; Fernhall, Bo

    2014-04-01

    Obesity is linked to cardiovascular disease, stroke, increased mortality and vascular remodeling. Although increased arterial diameter is associated with multiple cardiovascular risk factors and obesity, it is unknown whether lumen enlargement is accompanied by unfavorable vascular changes in young and otherwise healthy obese individuals. The purpose of this study was to compare carotid and brachial artery diameter, blood pressure, arterial stiffness, and endothelial function in young, apparently healthy, normal-weight, overweight, and obese male subjects. One hundred sixty-five male subjects (27.39±0.59 years) were divided into 3 groups (normal weight, overweight, and obese) according to body mass index. Subjects underwent cardiovascular measurements to determine arterial diameter, function, and stiffness. After adjusting for age, the obese group had significantly greater brachial, carotid, and aortic pressures, brachial pulse wave velocity, carotid intima media thickness, and carotid arterial diameter compared with both the overweight and normal-weight groups. Obesity is associated with a much worse arterial profile, as an increased carotid lumen size was accompanied by higher blood pressure, greater arterial stiffness, and greater carotid intima media thickness in obese compared with overweight or normal-weight individuals. These data suggest that although obesity may be a factor in arterial remodeling, such remodeling is also accompanied by other hemodynamic and arterial changes consistent with reduced arterial function and increased cardiovascular risk.

  19. EMP damage function of input port of DC solid state relay

    International Nuclear Information System (INIS)

    Sun Beiyun; Chen Xiangyue; Mao Congguang; Zhou Hui

    2009-01-01

    The principle of using pivotal quantity to estimate confidence interval for the cumulative distribution function at a specific value when the distribution is assumed to be normal is introduced. The damage function of input port of DC solide state relay is calculated by this method. This method can be used for vulnerability assessment. (authors)

  20. Cluster analysis in kinetic modelling of the brain: A noninvasive alternative to arterial sampling

    DEFF Research Database (Denmark)

    Liptrot, Matthew George; Adams, K.H.; Martiny, L.

    2004-01-01

    In emission tomography, quantification of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling. We propose a noninvasive alternative via the use of a blood vessel time-activity curve (TAC....... © 2003 Elsevier Inc. All rights reserved....

  1. Impaired renal allograft function is associated with increased arterial stiffness in renal transplant recipients

    DEFF Research Database (Denmark)

    Kneifel, M; Scholze, A; Burkert, A

    2006-01-01

    It is important whether impairment of renal allograft function may deteriorate arterial stiffness in renal transplant recipients. In a cross-sectional study, arterial vascular characteristics were non-invasively determined in 48 patients with renal allograft using applanation tonometry and digital...

  2. Determinants of Functional and Structural Properties of Large Arteries in Healthy Individuals

    Energy Technology Data Exchange (ETDEWEB)

    Tolezani, Elaine Cristina; Costa-Hong, Valéria, E-mail: hong.valeria@gmail.com; Correia, Gustavo; Mansur, Alfredo José; Drager, Luciano Ferreira; Bortolotto, Luiz Aparecido [Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil)

    2014-11-15

    Changes in the properties of large arteries correlate with higher cardiovascular risk. Recent guidelines have included the assessment of those properties to detect subclinical disease. Establishing reference values for the assessment methods as well as determinants of the arterial parameters and their correlations in healthy individuals is important to stratify patients. To assess, in healthy adults, the distribution of the values of pulse wave velocity, diameter, intima-media thickness and relative distensibility of the carotid artery, in addition to assessing the demographic and clinical determinants of those parameters and their correlations. This study evaluated 210 individuals (54% women; mean age, 44 ± 13 years) with no evidence of cardiovascular disease. The carotid-femoral pulse wave velocity was measured with a Complior{sup ®} device. The functional and structural properties of the carotid artery were assessed by using radiofrequency ultrasound. The means of the following parameters were: pulse wave velocity, 8.7 ± 1.5 m/s; diameter, 6,707.9 ± 861.6 μm; intima-media thickness, 601 ± 131 μm; relative distensibility, 5.3 ± 2.1%. No significant difference related to sex or ethnicity was observed. On multiple linear logistic regression, the factors independently related to the vascular parameters were: pulse wave velocity, to age (p < 0.01) and triglycerides (p = 0.02); intima-media thickness, to age (p < 0.01); diameter, to creatinine (p = 0.03) and age (p = 0.02); relative distensibility, to age (p < 0.01) and systolic and diastolic blood pressures (p = 0.02 and p = 0.01, respectively). Pulse wave velocity showed a positive correlation with intima media thickness (p < 0.01) and with relative distensibility (p < 0.01), while diameter showed a positive correlation with distensibility (p = 0.03). In healthy individuals, age was the major factor related to aortic stiffness, while age and diastolic blood pressure related to the carotid functional measure

  3. Determinants of Functional and Structural Properties of Large Arteries in Healthy Individuals

    International Nuclear Information System (INIS)

    Tolezani, Elaine Cristina; Costa-Hong, Valéria; Correia, Gustavo; Mansur, Alfredo José; Drager, Luciano Ferreira; Bortolotto, Luiz Aparecido

    2014-01-01

    Changes in the properties of large arteries correlate with higher cardiovascular risk. Recent guidelines have included the assessment of those properties to detect subclinical disease. Establishing reference values for the assessment methods as well as determinants of the arterial parameters and their correlations in healthy individuals is important to stratify patients. To assess, in healthy adults, the distribution of the values of pulse wave velocity, diameter, intima-media thickness and relative distensibility of the carotid artery, in addition to assessing the demographic and clinical determinants of those parameters and their correlations. This study evaluated 210 individuals (54% women; mean age, 44 ± 13 years) with no evidence of cardiovascular disease. The carotid-femoral pulse wave velocity was measured with a Complior ® device. The functional and structural properties of the carotid artery were assessed by using radiofrequency ultrasound. The means of the following parameters were: pulse wave velocity, 8.7 ± 1.5 m/s; diameter, 6,707.9 ± 861.6 μm; intima-media thickness, 601 ± 131 μm; relative distensibility, 5.3 ± 2.1%. No significant difference related to sex or ethnicity was observed. On multiple linear logistic regression, the factors independently related to the vascular parameters were: pulse wave velocity, to age (p < 0.01) and triglycerides (p = 0.02); intima-media thickness, to age (p < 0.01); diameter, to creatinine (p = 0.03) and age (p = 0.02); relative distensibility, to age (p < 0.01) and systolic and diastolic blood pressures (p = 0.02 and p = 0.01, respectively). Pulse wave velocity showed a positive correlation with intima media thickness (p < 0.01) and with relative distensibility (p < 0.01), while diameter showed a positive correlation with distensibility (p = 0.03). In healthy individuals, age was the major factor related to aortic stiffness, while age and diastolic blood pressure related to the carotid functional measure. The

  4. Determinants of Functional and Structural Properties of Large Arteries in Healthy Individuals

    Directory of Open Access Journals (Sweden)

    Elaine Cristina Tolezani

    2014-11-01

    Full Text Available Background: Changes in the properties of large arteries correlate with higher cardiovascular risk. Recent guidelines have included the assessment of those properties to detect subclinical disease. Establishing reference values for the assessment methods as well as determinants of the arterial parameters and their correlations in healthy individuals is important to stratify patients. Objective: To assess, in healthy adults, the distribution of the values of pulse wave velocity, diameter, intima-media thickness and relative distensibility of the carotid artery, in addition to assessing the demographic and clinical determinants of those parameters and their correlations. Methods: This study evaluated 210 individuals (54% women; mean age, 44 ± 13 years with no evidence of cardiovascular disease. The carotid-femoral pulse wave velocity was measured with a Complior® device. The functional and structural properties of the carotid artery were assessed by using radiofrequency ultrasound. Results: The means of the following parameters were: pulse wave velocity, 8.7 ± 1.5 m/s; diameter, 6,707.9 ± 861.6 μm; intima-media thickness, 601 ± 131 μm; relative distensibility, 5.3 ± 2.1%. No significant difference related to sex or ethnicity was observed. On multiple linear logistic regression, the factors independently related to the vascular parameters were: pulse wave velocity, to age (p < 0.01 and triglycerides (p = 0.02; intima-media thickness, to age (p < 0.01; diameter, to creatinine (p = 0.03 and age (p = 0.02; relative distensibility, to age (p < 0.01 and systolic and diastolic blood pressures (p = 0.02 and p = 0.01, respectively. Pulse wave velocity showed a positive correlation with intima media thickness (p < 0.01 and with relative distensibility (p < 0.01, while diameter showed a positive correlation with distensibility (p = 0.03. Conclusion: In healthy individuals, age was the major factor related to aortic stiffness, while age and diastolic

  5. Renal artery stenting in solitary functioning kidneys: Technical and clinical results

    International Nuclear Information System (INIS)

    Sahin, Sinan; Cimsit, Cagatay; Andac, Nurten; Baltacioglu, Feyyaz; Tuglular, Serhan; Akoglu, Emel

    2006-01-01

    Objective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions

  6. Renal artery stenting in solitary functioning kidneys: Technical and clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Sinan [Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Hospital, Department of Radiology, Istanbul (Turkey)]. E-mail: sinan.sahin@e-kolay.net; Cimsit, Cagatay [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Andac, Nurten [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Baltacioglu, Feyyaz [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Tuglular, Serhan [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey); Akoglu, Emel [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey)

    2006-01-15

    Objective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions.

  7. Favorable effects of concord grape juice on endothelial function and arterial stiffness in healthy smokers.

    Science.gov (United States)

    Siasos, Gerasimos; Tousoulis, Dimitris; Kokkou, Eleni; Oikonomou, Evangelos; Kollia, Maria-Eleni; Verveniotis, Aleksis; Gouliopoulos, Nikolaos; Zisimos, Konstantinos; Plastiras, Aris; Maniatis, Konstantinos; Stefanadis, Christodoulos

    2014-01-01

    Smoking is associated with impaired vascular function. Concord grape juice (CGJ), a rich source of flavonoids, can modify cardiovascular risk factors. Endothelial function and arterial stiffness are surrogate markers of arterial health. We examined the impact of CGJ on arterial wall properties in healthy smokers. We studied the effect of a 2-week oral treatment with CGJ in 26 healthy smokers on 3 occasions (day 0 (baseline), day 7, and day 14) in a randomized, placebo-controlled, double-blind, crossover study. Measurements were taken before (pSm), immediately after (Sm0), and 20 minutes after (Sm20) cigarette smoking. Endothelial function was evaluated by flow-mediated dilation (FMD) of the brachial artery. Carotid-femoral pulse wave velocity (PWV) was measured as an index of aortic stiffness. Compared with placebo, treatment with CGJ resulted in a significant improvement in pSm values of FMD (P = 0.02) and PWV (P = 0.04). At baseline, smoking decreased FMD in both the CGJ group (P FMD on day 7 (P = 0.02) and day 14 (P < 0.001). Moreover, at baseline, smoking induced a significant elevation in PWV in both the CGJ group (P = 0.02) and the placebo group (P = 0.04). Treatment with CGJ prevented the smoking-induced elevation in PWV on day 7 (P = 0.003) and day 14 (P < 0.001). CGJ consumption improved endothelial function and vascular elastic properties of the arterial tree in healthy smokers and attenuated acute smoking-induced impairment of arterial wall properties.

  8. Analysis of tracer transit in rat brain after carotid artery and femoral vein administrations using linear system theory.

    Science.gov (United States)

    Rudin, M; Beckmann, N; Sauter, A

    1997-01-01

    Determination of tissue perfusion rates by MRI bolus tracking methods relies on the central volume principle which states that tissue blood flow is given by the tissue blood volume divided by the mean tracer transit time (MTT). Accurate determination of the MTT requires knowledge of the arterial input function which in MRI experiments is usually not known, especially when using small animals. The problem of unknown arterial input can be circumvented in animal experiments by directly injecting the contrast agent into a feeding artery of the tissue of interest. In the present article the passage of magnetite nanoparticles through the rat cerebral cortex is analyzed after injection into the internal carotid artery. The results are discussed in the framework of linear system theory using a one-compartment model for brain tissue and by using the well characterized gamma-variate function to describe the tissue concentration profile of the contrast agent. The results obtained from the intra-arterial tracer administration experiments are then compared with the commonly used intra-venous injection of the contrast agent in order to estimate the contribution of the peripheral circulation to the MTT values in the latter case. The experiments were analyzed using a two-compartment model and the gamma-variate function. As an application perfusion rates in normal and ischemic cerebral cortex of hypertensive rats were estimated in a model of focal cerebral ischemia. The results indicate that peripheral circulation has a significant influence on the MTT values and thus on the perfusion rates, which cannot be neglected.

  9. Hyperuricemia in Destabilization of Endothelial Function in Adolescents with Arterial Hypertension

    Directory of Open Access Journals (Sweden)

    N.M. Korenev

    2013-08-01

    Full Text Available The objective of this work was to study the correlation of uric acid level in blood serum and parameters of endothelial function and non-specific inflammation in adolescents with arterial hypertension considering their body weight. In the most of patients with arterial hypertension endothelial dysfunction was detected; endothelium-dependent vasodilation was more altered in the patients with obesity and especially in those with hyperuricemia. An increase in C-reactive protein serum level was mainly associated with obesity; a decrease in systolic-diastolic ratio — with hyperuricemia.

  10. Distance-Ranked Fault Identification of Reconfigurable Hardware Bitstreams via Functional Input

    Directory of Open Access Journals (Sweden)

    Naveed Imran

    2014-01-01

    Full Text Available Distance-Ranked Fault Identification (DRFI is a dynamic reconfiguration technique which employs runtime inputs to conduct online functional testing of fielded FPGA logic and interconnect resources without test vectors. At design time, a diverse set of functionally identical bitstream configurations are created which utilize alternate hardware resources in the FPGA fabric. An ordering is imposed on the configuration pool as updated by the PageRank indexing precedence. The configurations which utilize permanently damaged resources and hence manifest discrepant outputs, receive lower rank are thus less preferred for instantiation on the FPGA. Results indicate accurate identification of fault-free configurations in a pool of pregenerated bitstreams with a low number of reconfigurations and input evaluations. For MCNC benchmark circuits, the observed reduction in input evaluations is up to 75% when comparing the DRFI technique to unguided evaluation. The DRFI diagnosis method is seen to isolate all 14 healthy configurations from a pool of 100 pregenerated configurations, and thereby offering a 100% isolation accuracy provided the fault-free configurations exist in the design pool. When a complete recovery is not feasible, graceful degradation may be realized which is demonstrated by the PSNR improvement of images processed in a video encoder case study.

  11. Multi detector input and function generator for polarized neutron experiments

    International Nuclear Information System (INIS)

    De Blois, J.; Beunes, A.J.H.; Ende, P. v.d.; Osterholt, E.A.; Rekveldt, M.T.; Schipper, M.N.; Velthuis, S.G.E. te

    1998-01-01

    In this paper a VME module is described for static or stroboscopic measurements with a neutron scattering instrument, consisting essentially of a series of up to 64 3 He neutron detectors around a sample environment. Each detector is provided with an amplifier and a discriminator to separate the neutrons from noise. To reduce the wiring, the discriminator outputs are connected to the module by coding boxes. Two 16-inputs to one-output coding boxes generate serial output codes on a fiber optic connection. This basically fast connection reduces the dead time introduced by the coding, and the influence of environmental noise. With stroboscopic measurements a periodic function is used to affect the sample surrounded by a field coil. Each detected neutron is labeled with a data label containing the detector number and the time of detection with respect to a time reference. The data time base can be programmed on a linear or a nonlinear scale. An external source or an attribute of the periodic function may generate the time reference pulse. A 12-bit DAC connected to the output of an 8 K, 16-bits memory, where the pattern of the current has been stored before, generates the function. The function memory is scanned by the programmable function time base. Attributes are set by the four remaining bits of the memory. One separate detector input connects a monitor detector in the neutron beam with a 32-bit counter/timer that provides measuring on a preset count, preset time or preset frame. (orig.)

  12. [System analytical approach of lung function and hemodynamics].

    Science.gov (United States)

    Naszlady, Attila; Kiss, Lajos

    2009-02-15

    The authors critically analyse the traditional views in physiology and complete them with new statements based on computer model simulations of lung function and of hemodynamics. Conclusions are derived for the clinical practice as follows: the four-dimensional function curves are similar in both systems; there is a "waterfall" zone in the pulmonary blood perfusion; the various time constants of pulmonary regions can modify the blood gas values; pulmonary capillary pressure is equal to pulmonary arterial diastole pressure; heart is not a pressure pump, but a flow source; ventricles are loaded by the input impedance of the arterial systems and not by the total vascular (ohmlike) resistance; optimum heart rate in rest depends on the length of the aorta; this law of heart rate, based on the principle of resonance is valid along the mammalian allometric line; tachycardia decreases the input impedance; using positive end expiratory pressure respirators the blood gas of pulmonary artery should be followed; coronary circulation should be assessed in beat per milliliter, the milliliter per minute may be false. These statements are compared to related references.

  13. How the type of input function affects the dynamic response of conducting polymer actuators

    Science.gov (United States)

    Xiang, Xingcan; Alici, Gursel; Mutlu, Rahim; Li, Weihua

    2014-10-01

    There has been a growing interest in smart actuators typified by conducting polymer actuators, especially in their (i) fabrication, modeling and control with minimum external data and (ii) applications in bio-inspired devices, robotics and mechatronics. Their control is a challenging research problem due to the complex and nonlinear properties of these actuators, which cannot be predicted accurately. Based on an input-shaping technique, we propose a new method to improve the conducting polymer actuators’ command-following ability, while minimizing their electric power consumption. We applied four input functions with smooth characteristics to a trilayer conducting polymer actuator to experimentally evaluate its command-following ability under an open-loop control strategy and a simulated feedback control strategy, and, more importantly, to quantify how the type of input function affects the dynamic response of this class of actuators. We have found that the four smooth inputs consume less electrical power than sharp inputs such as a step input with discontinuous higher-order derivatives. We also obtained an improved transient response performance from the smooth inputs, especially under the simulated feedback control strategy, which we have proposed previously [X Xiang, R Mutlu, G Alici, and W Li, 2014 “Control of conducting polymer actuators without physical feedback: simulated feedback control approach with particle swarm optimization’, Journal of Smart Materials and Structure, 23]. The idea of using a smooth input command, which results in lower power consumption and better control performance, can be extended to other smart actuators. Consuming less electrical energy or power will have a direct effect on enhancing the operational life of these actuators.

  14. How the type of input function affects the dynamic response of conducting polymer actuators

    International Nuclear Information System (INIS)

    Xiang, Xingcan; Alici, Gursel; Mutlu, Rahim; Li, Weihua

    2014-01-01

    There has been a growing interest in smart actuators typified by conducting polymer actuators, especially in their (i) fabrication, modeling and control with minimum external data and (ii) applications in bio-inspired devices, robotics and mechatronics. Their control is a challenging research problem due to the complex and nonlinear properties of these actuators, which cannot be predicted accurately. Based on an input-shaping technique, we propose a new method to improve the conducting polymer actuators’ command-following ability, while minimizing their electric power consumption. We applied four input functions with smooth characteristics to a trilayer conducting polymer actuator to experimentally evaluate its command-following ability under an open-loop control strategy and a simulated feedback control strategy, and, more importantly, to quantify how the type of input function affects the dynamic response of this class of actuators. We have found that the four smooth inputs consume less electrical power than sharp inputs such as a step input with discontinuous higher-order derivatives. We also obtained an improved transient response performance from the smooth inputs, especially under the simulated feedback control strategy, which we have proposed previously [X Xiang, R Mutlu, G Alici, and W Li, 2014 “Control of conducting polymer actuators without physical feedback: simulated feedback control approach with particle swarm optimization’, Journal of Smart Materials and Structure, 23]. The idea of using a smooth input command, which results in lower power consumption and better control performance, can be extended to other smart actuators. Consuming less electrical energy or power will have a direct effect on enhancing the operational life of these actuators. (paper)

  15. SU-G-IeP1-12: Size Selective Arterial Cerebral Blood Volume Mapping Using Multiple Inversion Time Arterial Spin Labeling

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Y; Johnston, M; Whitlow, C [Wake Forest School of Medicine, Winston-salem, NC (United States); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of a novel method for size specific arterial cerebral blood volume (aCBV) mapping using pseudo-continuous arterial spin labeling (PCASL), with multiple TI. Methods: Multiple PCASL images were obtained from a subject with TI of [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms. Each TI pair was averaged six times. Two scans were performed: one without a flow crusher gradient and the other with a crusher gradient (10cm/s in three directions) to remove signals from large arteries. Scan times were 5min. without a crusher gradient and 5.5 min with a crusher gradient. Non-linear fitting algorithm finds the minimum mean squared solution of per-voxel based aCBV, cerebral blood flow, and arterial transit time, and fits the data into a hemodynamic model that represents superposition of blood volume and flow components within a single voxel. Results: aCBV maps with a crusher gradient represent signals from medium and small sized arteries, while those without a crusher gradient represent signals from all sized arteries, indicating that flow crusher gradients can be effectively employed to achieve size-specific aCBV mapping. Regardless of flow crusher, the CBF and ATT maps are very similar in appearance. Conclusion: Quantitative size selective blood volume mapping controlled by a flow crusher is feasible without additional information because the ASL quantification process doesn’t require an arterial input function measured from a large artery. The size specific blood volume mapping is not interfered by sSignals from large arteries do not interfere with size specific aCBV mapping in the applications of interest in for applications in which only medium or small arteries are of interest.

  16. File list: InP.CDV.10.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.10.AllAg.Carotid_Arteries hg19 Input control Cardiovascular Carotid Arterie...s DRX021452,DRX021453,DRX021454 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.10.AllAg.Carotid_Arteries.bed ...

  17. File list: InP.CDV.50.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.50.AllAg.Carotid_Arteries hg19 Input control Cardiovascular Carotid Arterie...s DRX021452,DRX021453,DRX021454 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.50.AllAg.Carotid_Arteries.bed ...

  18. File list: InP.CDV.05.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.05.AllAg.Carotid_Arteries hg19 Input control Cardiovascular Carotid Arterie...s DRX021453,DRX021454,DRX021452 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.05.AllAg.Carotid_Arteries.bed ...

  19. File list: InP.CDV.20.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.20.AllAg.Carotid_Arteries hg19 Input control Cardiovascular Carotid Arterie...s DRX021452,DRX021453,DRX021454 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.20.AllAg.Carotid_Arteries.bed ...

  20. Design of a Code-Maker Translator Assistive Input Device with a Contest Fuzzy Recognition Algorithm for the Severely Disabled

    Directory of Open Access Journals (Sweden)

    Chung-Min Wu

    2015-01-01

    Full Text Available This study developed an assistive system for the severe physical disabilities, named “code-maker translator assistive input device” which utilizes a contest fuzzy recognition algorithm and Morse codes encoding to provide the keyboard and mouse functions for users to access a standard personal computer, smartphone, and tablet PC. This assistive input device has seven features that are small size, easy installing, modular design, simple maintenance, functionality, very flexible input interface selection, and scalability of system functions, when this device combined with the computer applications software or APP programs. The users with severe physical disabilities can use this device to operate the various functions of computer, smartphone, and tablet PCs, such as sending e-mail, Internet browsing, playing games, and controlling home appliances. A patient with a brain artery malformation participated in this study. The analysis result showed that the subject could make himself familiar with operating of the long/short tone of Morse code in one month. In the future, we hope this system can help more people in need.

  1. Quantification of brain perfusion SPECT with N-isopropyl-p-iodoamphetamine using noninvasive microsphere method. Estimation of arterial input by dynamic imaging

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Sugihara, Hideki; Taniguchi, Yoshimitsu; Aoki, Etsuo; Furuichi, Kenji; Miyazaki, Yoshiharu.

    1997-01-01

    We have developed a noninvasive method to quantify brain perfusion SPECT with 123 I-N-isopropyl-p-iodoamphetamine (IMP) using serial dynamic planar imaging of the initial transit phase. The method is based on the microsphere model, but does not require arterial sampling. Serial dynamic planar imaging was performed for 6 min after the bolus injection of IMP (167 MBq in 1.5 ml), followed by additional planar imaging at 20 min and SPECT scan thereafter. The total arterial input to the brain during the initial 5 min after injection was estimated by the injected dose, with the correction of the lung retention, divided by cardiac output (CO). CO was estimated from the initial transit of IMP in the right heart. Cardiac output index (COI), obtained from the integral of the first transit of IMP in the right heart divided by the injected dose, was calibrated by CO measured by Doppler ultrasonography. Regional cerebral blood flow (rCBF) obtained by this method in normal subjects was acceptable. However, the results may be influenced by the injection technique, and careful attention should be considered for clinical application of this method. (author)

  2. Genetic algorithm based input selection for a neural network function approximator with applications to SSME health monitoring

    Science.gov (United States)

    Peck, Charles C.; Dhawan, Atam P.; Meyer, Claudia M.

    1991-01-01

    A genetic algorithm is used to select the inputs to a neural network function approximator. In the application considered, modeling critical parameters of the space shuttle main engine (SSME), the functional relationship between measured parameters is unknown and complex. Furthermore, the number of possible input parameters is quite large. Many approaches have been used for input selection, but they are either subjective or do not consider the complex multivariate relationships between parameters. Due to the optimization and space searching capabilities of genetic algorithms they were employed to systematize the input selection process. The results suggest that the genetic algorithm can generate parameter lists of high quality without the explicit use of problem domain knowledge. Suggestions for improving the performance of the input selection process are also provided.

  3. Flow-mediated dilation and peripheral arterial tonometry are disturbed in preeclampsia and reflect different aspects of endothelial function.

    Science.gov (United States)

    Mannaerts, Dominique; Faes, Ellen; Goovaerts, Inge; Stoop, Tibor; Cornette, Jerome; Gyselaers, Wilfried; Spaanderman, Marc; Van Craenenbroeck, Emeline M; Jacquemyn, Yves

    2017-11-01

    Endothelial function and arterial stiffness are known to be altered in preeclamptic pregnancies. Previous studies have shown conflicting results regarding the best technique for assessing vascular function in pregnancy. In this study, we made a comprehensive evaluation of in vivo vascular function [including flow-mediated dilatation (FMD), peripheral arterial tonometry (PAT), and arterial stiffness] in preeclamptic patients and compared them with normal pregnancies. In addition, we assessed the relation between vascular function and systemic inflammation. Fourteen patients with preeclampsia (PE) and 14 healthy pregnant controls were included. Endothelial function was determined by FMD and PAT and arterial stiffness by carotid-femoral pulse-wave velocity and augmentation index. Systemic inflammation was assessed using mean platelet volume (MPV) and neutrophil-lymphocyte ratio (NLR). The reactive hyperemia index, assessed using PAT, is decreased at the third trimester compared with the first trimester in a normal, uncomplicated pregnancy ( P = 0.001). Arterial stiffness is significantly higher in PE versus normal pregnancy ( P function, obtained by FMD, is deteriorated in PE versus normal pregnancy ( P = 0.015), whereas endothelial function assessment by PAT is improved in PE versus normal pregnancy ( P = 0.001). Systemic inflammation (MPV and NLR) increases during normal pregnancy. FMD and PAT are disturbed in PE. Endothelial function, assessed by FMD and PAT, shows distinct results. This may indicate that measurements with FMD and PAT reflect different aspects of endothelial function and that PAT should not be used as a substitute for FMD as a measure of endothelial function in pregnancy. Copyright © 2017 the American Physiological Society.

  4. Effects of cranberry juice consumption on vascular function in patients with coronary artery disease.

    Science.gov (United States)

    Dohadwala, Mustali M; Holbrook, Monika; Hamburg, Naomi M; Shenouda, Sherene M; Chung, William B; Titas, Megan; Kluge, Matthew A; Wang, Na; Palmisano, Joseph; Milbury, Paul E; Blumberg, Jeffrey B; Vita, Joseph A

    2011-05-01

    Cranberry juice contains polyphenolic compounds that could improve endothelial function and reduce cardiovascular disease risk. The objective was to examine the effects of cranberry juice on vascular function in subjects with coronary artery disease. We completed an acute pilot study with no placebo (n = 15) and a chronic placebo-controlled crossover study (n = 44) that examined the effects of cranberry juice on vascular function in subjects with coronary artery disease. In the chronic crossover study, subjects with coronary heart disease consumed a research preparation of double-strength cranberry juice (54% juice, 835 mg total polyphenols, and 94 mg anthocyanins) or a matched placebo beverage (480 mL/d) for 4 wk each with a 2-wk rest period between beverages. Beverage order was randomly assigned, and participants refrained from consuming other flavonoid-containing beverages during the study. Vascular function was measured before and after each beverage, with follow-up testing ≥12 h after consumption of the last beverage. Mean (±SD) carotid-femoral pulse wave velocity, a measure of central aortic stiffness, decreased after cranberry juice (8.3 ± 2.3 to 7.8 ± 2.2 m/s) in contrast with an increase after placebo (8.0 ± 2.0 to 8.4 ± 2.8 m/s) (P = 0.003). Brachial artery flow-mediated dilation, digital pulse amplitude tonometry, blood pressure, and carotid-radial pulse wave velocity did not change. In the uncontrolled pilot study, we observed improved brachial artery flow-mediated dilation (7.7 ± 2.9% to 8.7 ± 3.1%, P = 0.01) and digital pulse amplitude tonometry ratio (0.10 ± 0.12 to 0.23 ± 0.16, P = 0.001) 4 h after consumption of a single 480-mL portion of cranberry juice. Chronic cranberry juice consumption reduced carotid femoral pulse wave velocity-a clinically relevant measure of arterial stiffness. The uncontrolled pilot study suggested an acute benefit; however, no chronic effect on measures of endothelial vasodilator function was found. This trial

  5. Obesity, arterial function and arterial structure – a systematic review and meta‐analysis

    Science.gov (United States)

    Ne, J. Y. A.; Cai, T. Y.; Celermajer, D. S.; Caterson, I. D.; Gill, T.; Lee, C. M. Y.

    2017-01-01

    Summary Objective Obesity is an established risk factor for cardiovascular disease. The mechanisms by which obesity affects cardiovascular risk have not been fully elucidated. This paper reports a comprehensive systematic review and meta‐analysis on obesity and two key aspects of vascular health using gold‐standard non‐invasive measures – arterial endothelial function (brachial flow‐mediated dilatation) and subclinical atherosclerosis (carotid intima‐media thickness). Methods Electronic searches for ‘Obesity and flow‐mediated dilatation’ and ‘Obesity and intima‐media thickness’ were performed using Ovid Medline and Embase databases. A meta‐analysis was undertaken for brachial flow‐mediated dilatation and carotid intima‐media thickness to obtain pooled estimates for adults with obesity and those with healthy weight. Results Of the 5,810 articles retrieved, 19 studies on flow‐mediated dilatation and 19 studies on intima‐media thickness were included. Meta‐analysis demonstrated that obesity was associated with lower flow‐mediated dilatation (−1.92 % [95% CI −2.92, −0.92], P = 0.0002) and greater carotid intima‐media thickness (0.07 mm [95% CI 0.05, 0.08], P Obesity is associated with poorer arterial endothelial function and increased subclinical atherosclerosis, consistent with these aspects of vascular health at least partially contributing to the increased risk of cardiovascular events in adults with obesity. These estimated effect sizes will enable vascular health benefits in response to weight loss treatment to be put in greater perspective, both in the research setting and potentially also clinical practice. PMID:28702212

  6. Evaluation of pulmonary arterial morphology and function in cyanotic congenital heart disease by MRI and cine MRI

    International Nuclear Information System (INIS)

    Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Ichida, Fukiko; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke; Nakajima, Kenshuu; Nakajima, Akio

    1993-01-01

    Pulmonary arterial anatomy was evaluated by magnetic resonance imaging (MRI), angiography and two-dimensional echocardiography in 20 patients with cyanotic heart disease associated with decreased pulmonary blood flow. Excellent correlation between MRI and angiographic estimates of pulmonary artery diameter was obtained (main pulmonary artery, r=0.87; right pulmonary artery, r=0.96; left pulmonary artery, r=0.95). However, echocardiography could not describe peripheral pulmonary arteries obviously, especially left pulmonary artery. In the assessment of peripheral pulmonary stenosis or obstruction, cine MRI was superior to echocardiography. We conclude that MRI and cine MRI will play an important role in the serial evaluation of pulmonary arterial morphology and function in patients with cyanotic congenital heart disease before and after surgical repair. (author)

  7. Evaluation of pulmonary arterial morphology and function in cyanotic congenital heart disease by MRI and cine MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Ichida, Fukiko; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke; Nakajima, Kenshuu; Nakajima, Akio [Toyama Medical and Pharmaceutical Univ. (Japan)

    1993-01-01

    Pulmonary arterial anatomy was evaluated by magnetic resonance imaging (MRI), angiography and two-dimensional echocardiography in 20 patients with cyanotic heart disease associated with decreased pulmonary blood flow. Excellent correlation between MRI and angiographic estimates of pulmonary artery diameter was obtained (main pulmonary artery, r=0.87; right pulmonary artery, r=0.96; left pulmonary artery, r=0.95). However, echocardiography could not describe peripheral pulmonary arteries obviously, especially left pulmonary artery. In the assessment of peripheral pulmonary stenosis or obstruction, cine MRI was superior to echocardiography. We conclude that MRI and cine MRI will play an important role in the serial evaluation of pulmonary arterial morphology and function in patients with cyanotic congenital heart disease before and after surgical repair. (author).

  8. Estimating the basilar-membrane input-output function in normal-hearing and hearing-impaired listeners

    DEFF Research Database (Denmark)

    Jepsen, Morten Løve; Dau, Torsten

    To partly characterize the function of cochlear processing in humans, the basilar membrane (BM) input-output function can be estimated. In recent studies, forward masking has been used to estimate BM compression. If an on-frequency masker is processed compressively, while an off-frequency masker...... is transformed more linearly, the ratio between the slopes of growth of masking (GOM) functions provides an estimate of BM compression at the signal frequency. In this study, this paradigm is extended to also estimate the knee-point of the I/O-function between linear rocessing at low levels and compressive...... processing at medium levels. If a signal can be masked by a low-level on-frequency masker such that signal and masker fall in the linear region of the I/O-function, then a steeper GOM function is expected. The knee-point can then be estimated in the input level region where the GOM changes significantly...

  9. Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (II): Applications in spine diagnostics and assessment of crohn's disease.

    Science.gov (United States)

    van Schie, Jeroen J N; Lavini, Cristina; van Vliet, Lucas J; Kramer, Gem; Pieters-van den Bos, Indra; Marcus, J T; Stoker, Jaap; Vos, Frans M

    2018-05-01

    Pharmacokinetic (PK) models can describe microvascular density and integrity. An essential component of PK models is the arterial input function (AIF) representing the time-dependent concentration of contrast agent (CA) in the blood plasma supplied to a tissue. To evaluate a novel method for subject-specific AIF estimation that takes inflow effects into account. Retrospective study. Thirteen clinical patients referred for spine-related complaints; 21 patients from a study into luminal Crohn's disease with known Crohn's Disease Endoscopic Index of Severity (CDEIS). Dynamic fast spoiled gradient echo (FSPGR) at 3T. A population-averaged AIF, AIFs derived from distally placed regions of interest (ROIs), and the new AIF method were applied. Tofts' PK model parameters (including v p and K trans ) obtained with the three AIFs were compared. In the Crohn's patients K trans was correlated to CDEIS. The median values of the PK model parameters from the three methods were compared using a Mann-Whitney U-test. The associated variances were statistically assessed by the Brown-Forsythe test. Spearman's rank correlation coefficient was computed to test the correlation of K trans to CDEIS. The median v p was significantly larger when using the distal ROI approach, compared to the two other methods (P < 0.05 for both comparisons, in both applications). Also, the variances in v p were significantly larger with the ROI approach (P < 0.05 for all comparisons). In the Crohn's disease study, the estimated K trans parameter correlated better with the CDEIS (r = 0.733, P < 0.001) when the proposed AIF was used, compared to AIFs from the distal ROI method (r = 0.429, P = 0.067) or the population-averaged AIF (r = 0.567, P = 0.011). The proposed method yielded realistic PK model parameters and improved the correlation of the K trans parameter with CDEIS, compared to existing approaches. 3 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2018;47:1197-1204. © 2017

  10. Acute arterial occlusion - kidney

    Science.gov (United States)

    ... main artery to the kidney is called the renal artery. Reduced blood flow through the renal artery can hurt kidney function. ... need include: Duplex Doppler ultrasound exam of the renal arteries to test blood flow MRI of the kidney arteries, which can show ...

  11. Relationship of carotid arterial functional and structural changes to left atrial volume in untreated hypertension.

    Science.gov (United States)

    Jaroch, Joanna; Rzyczkowska, Barbara; Bociąga, Zbigniew; Vriz, Olga; Driussi, Caterina; Loboz-Rudnicka, Maria; Dudek, Krzysztof; Łoboz-Grudzień, Krystyna

    2016-04-01

    The contribution of arterial functional and structural changes to left ventricular (LV) diastolic dysfunction has been the area of recent research. There are some studies on the relationship between arterial stiffness (a.s.) and left atrial (LA) remodelling as a marker of diastolic burden. Little is known about the association of arterial structural changes and LA remodelling in hypertension (H). The aim of this study was to examine the relationship between carotid a.s. and intima-media thickness (IMT) and LA volume in subjects with H. The study included 245 previously untreated hypertensives (166 women and 79 men, mean age 53.7 ± 11.8 years). Each patient was subjected to echocardiography with measurement of LA volume, evaluation of left ventricular hypertrophy (LVH) and LV systolic/diastolic function indices, integrated assessment of carotid IMT and echo-tracking of a.s. and wave reflection parameters. Univariate regression analysis revealed significant correlations between indexed LA volume and selected clinical characteristics, echocardiographic indices of LVH and LV diastolic/systolic function and a.s./wave reflection parameters. The following parameters were identified as independent determinants of indexed LA volume on multivariate regression analysis: diastolic blood pressure (beta = -0.229, P arterial stiffness but not intima-media thickness and LA volume in patients with untreated hypertension.

  12. Influence of carotid artery stenting on cognitive function

    Energy Technology Data Exchange (ETDEWEB)

    Quasar Grunwald, Iris [Saarland University Clinic, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Department of Neuroradiology, Homburg (Germany); Papanagiotou, Panagiotis; Backens, Martin; Politi, Maria; Vedder, Verena; Zercher, K. [Saarland University Clinic, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Reith, Wolfgang; Supprian, Tilman; Muscalla, B.; Haass, Anton; Krick, Christoph M. [Saarland University Clinic, Clinic for Neurology, Homburg (Germany); Saarland University Clinic, Clinic for Psychiatry and Psychotherapy, Homburg (Germany)

    2010-01-15

    There have only been a few studies on cognitive changes in patients with carotid occlusive disease, and the results of these show major discrepancies in the extent to which treatment affects neuropsychological function. We sought to clarify these discrepancies by evaluating the effects of carotid artery stenting (CAS) on the cognitive function. Forty-one asymptomatic CAS patients were administered a test battery of neuropsychological tests measuring cognitive speed and memory function before and 3 months after the procedure. A control group was also evaluated. To test for thromboembolic lesions, diffusion-weighted imaging was used. CAS led to a significant increase in cognitive speed (p < 0.001) but did not afford any change in memory function. This was regardless of the degree or side of stenosis or patient age or gender. CAS significantly improved functions that involve cognitive speed. Earlier studies did not differentiate between speed and memory tests and thus might have missed these changes. Further studies correlating changes in brain perfusion with increase in cognitive speed are needed. (orig.)

  13. Influence of carotid artery stenting on cognitive function

    International Nuclear Information System (INIS)

    Quasar Grunwald, Iris; Papanagiotou, Panagiotis; Backens, Martin; Politi, Maria; Vedder, Verena; Zercher, K.; Reith, Wolfgang; Supprian, Tilman; Muscalla, B.; Haass, Anton; Krick, Christoph M.

    2010-01-01

    There have only been a few studies on cognitive changes in patients with carotid occlusive disease, and the results of these show major discrepancies in the extent to which treatment affects neuropsychological function. We sought to clarify these discrepancies by evaluating the effects of carotid artery stenting (CAS) on the cognitive function. Forty-one asymptomatic CAS patients were administered a test battery of neuropsychological tests measuring cognitive speed and memory function before and 3 months after the procedure. A control group was also evaluated. To test for thromboembolic lesions, diffusion-weighted imaging was used. CAS led to a significant increase in cognitive speed (p < 0.001) but did not afford any change in memory function. This was regardless of the degree or side of stenosis or patient age or gender. CAS significantly improved functions that involve cognitive speed. Earlier studies did not differentiate between speed and memory tests and thus might have missed these changes. Further studies correlating changes in brain perfusion with increase in cognitive speed are needed. (orig.)

  14. Effect of age on left ventricular function during exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Hakki, A.H.; DePace, N.L.; Iskandrian, A.S.

    1983-01-01

    The purpose of this study was to assess the effect of age on left ventricular performance during exercise in 79 patients with coronary artery disease (greater than or equal to 50% narrowing of one or more major coronary arteries). Fifty patients under the age of 60 years (group I) and 29 patients 60 years or older (group II) were studied. Radionuclide angiograms were obtained at rest and during symptom-limited upright bicycle exercise. The history of hypertension, angina or Q wave myocardial infarction was similar in both groups. Multivessel coronary artery disease was present in 30 patients (60%) in group I and in 19 patients (66%) in group II (p . not significant). There were no significant differences between the two groups in the hemodynamic variables (at rest or during exercise) of left ventricular ejection fraction, end-diastolic volume, end-systolic volume and cardiac index. Exercise tolerance was higher in group I than in group II (7.8 +/- 0.4 versus 5.7 +/- 0.4 minutes, p . 0.009), although the exercise heart rate and rate-pressure product were not significantly different between the groups. There was poor correlation between age and ejection fraction, end-diastolic volume and end-systolic volume at rest and during exercise. Abnormal left ventricular function at rest or an abnormal response to exercise was noted in 42 patients (84%) in group I and in 25 patients (86%) in group II (p . not significant). Thus, in patients with coronary artery disease, age does not influence left ventricular function at rest or response to exercise. Older patients with coronary artery disease show changes in left ventricular function similar to those in younger patients with corresponding severity of coronary artery disease

  15. Effect of uterine arterial embolization on the ovarian function in puerpera with postpartum hemorrhage

    Directory of Open Access Journals (Sweden)

    Yan-Xian Deng

    2017-06-01

    Full Text Available Objective: To observe the hemostatic effect of uterine arterial embolization in the treatment of postpartum hemorrhage and the effect on menstruation, sex hormone level, ovarian function, and pelvic floor function. Methods: A total of 45 patients with postpartum hemorrhage who were admitted in the Department of Obstetrics of our hospital from January, 2014 to June, 2016 for uterine arterial embolization were included in the study and served as the treatment group. The postoperative menstruation recovery was recorded. The hormone levels, ovarian function, and pelvic floor function before and after treatment were recorded. A total of 42 normal puerpera were served as the control group. The menstrual status of the two groups after menstruation was compared. Results: Rapid and effective hemostasis could be obtained from patients in the treatment group after treatment with hemostasis success rate of 100%. The comparison of menstruation cycle and menstruation days after treatment between the two groups was not statistically significant. The levels of E2, P, FSH, LH and PRL, ovarian function index RI and PI, pelvic floor muscle fatigue and vaginal dynamic pressure before and after 3 and 6 months had no significant difference, and there was no significant difference between the 2 groups. Conclusions: Uterine arterial embolization in the treatment of postpartum hemorrhage is effective, and has no influence on the patient's menstrual conditions, sex hormone levels, ovarian and pelvic floor functions; therefore, it is worthy of clinical application.

  16. Cardiac structure and function, and ventricular-arterial interaction 11 years following a pregnancy with preeclampsia.

    Science.gov (United States)

    Al-Nashi, Maha; Eriksson, Maria J; Östlund, Eva; Bremme, Katarina; Kahan, Thomas

    2016-04-01

    Preeclampsia (PE) is associated with acute left ventricular dysfunction. Whether these changes eventually resolve remains unclear. This study assessed left and right ventricular structure and function, and ventricular-arterial interaction in 15 women 11 years after a pregnancy with PE and 16 matched control subjects with a normal pregnancy. We found normal left and right ventricular dimensions, systolic function, and global left ventricular strain, with no differences between the groups. In addition, indices of diastolic function, left and right atrial size, and amino-terminal pro-brain natriuretic peptide were normal and did not differ between the groups. Women with a previous PE had impaired night/day ratios for systolic and diastolic ambulatory blood pressure. However, indices of aortic stiffness or ventricular-arterial coupling did not differ between the groups. In conclusion, we could not demonstrate remaining alterations in systolic or diastolic left or right ventricular function, or in ventricular-arterial interaction in women 11 years after PE. Copyright © 2016 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  17. [Influence of Sympathetic Denervation of the Renal Artery on the Level of Arterial Blood Pressure, Cerebral Blood Flow and Cognitive Function In Patients With Resistant Arterial Hypertension].

    Science.gov (United States)

    Efimova, Y N; Lichikaki, A V; Lishmanov, B Y

    2017-07-01

    To study the effect of radiofrequency ablation of renal arteries on regional cerebral blood flow and cognitive function in patients with resistant arterial hypertension (AH). Transcatheter renal denervation (TRD) was performed in 17 patients with resistant AH. Examination before and after TRD included SPECT with mTc-HMPAO, 24-hours blood pressure (BP) monitoring, and comprehensive neuropsychological testing. Fifteen patients without angiographic signs of carotid atherosclerosis, coronary artery disease and AH, neurological and psychiatric disorders were investigated as control group. Compared with control group patients with AH had decreases of regional cerebral blood flow (rCBF) in right (by 13.5%, p=0.00002) and left (by 15.5%, p=0.0006) inferior frontal lobes, in right temporal brain region (by 11.5%, p=0.008); in right and left occipital lobes (by 8.2%, p=0.04). In 6 months after TRD we observed significant improvement of cognitive function, parameters of 24-hour BP monitoring, and rCBF. We also noted definite close interdependence between changes of rCBF, indices of 24-hours BP monitoring, and dynamics of cognitive function. Improvement of long-term verbal memory correlated with increases of rCBF in left superior frontal and right occipital regions while dynamics of mentation and attention correlated positively with augmentation of rCBF in right posterior parietal region. Changes of perfusion in inferior parts of left frontal lobe and in right occipital region correlated with dynamics of index of diurnal diastolic hypertension time (R2=0.64, p=0.001, and R2=0.60, p=0.03, respectively). Our results suggest, that in patients with resistant AH positive effect of TRD on levels of 24-hour mean BP as well as on indices of BP load leads to in augmentation of rCBF and improvement of cognitive function.

  18. Effect of acute moderate exercise on induced inflammation and arterial function in older adults.

    Science.gov (United States)

    Ranadive, Sushant Mohan; Kappus, Rebecca Marie; Cook, Marc D; Yan, Huimin; Lane, Abbi Danielle; Woods, Jeffrey A; Wilund, Kenneth R; Iwamoto, Gary; Vanar, Vishwas; Tandon, Rudhir; Fernhall, Bo

    2014-04-01

    Acute inflammation reduces flow-mediated vasodilatation and increases arterial stiffness in young healthy individuals. However, this response has not been studied in older adults. The aim of this study, therefore, was to evaluate the effect of acute induced systemic inflammation on endothelial function and wave reflection in older adults. Furthermore, an acute bout of moderate-intensity aerobic exercise can be anti-inflammatory. Taken together, we tested the hypothesis that acute moderate-intensity endurance exercise, immediately preceding induced inflammation, would be protective against the negative effects of acute systemic inflammation on vascular function. Fifty-nine healthy volunteers between 55 and 75 years of age were randomized to an exercise or a control group. Both groups received a vaccine (induced inflammation) and sham (saline) injection in a counterbalanced crossover design. Inflammatory markers, endothelial function (flow-mediated vasodilatation) and measures of wave reflection and arterial stiffness were evaluated at baseline and at 24 and 48 h after injections. There were no significant differences in endothelial function and arterial stiffness between the exercise and control group after induced inflammation. The groups were then analysed together, and we found significant differences in the inflammatory markers 24 and 48 h after induction of acute inflammation compared with sham injection. However, flow-mediated vasodilatation, augmentation index normalized for heart rate (AIx75) and β-stiffness did not change significantly. Our results suggest that acute inflammation induced by influenza vaccination did not affect endothelial function in older adults.

  19. [Echo-tracking technology for evaluating femoral artery endothelial function in patients with Grave's disease].

    Science.gov (United States)

    Wei, Wei; Wang, Jingyuan; Zhao, Qiaoling; Yang, Jinru

    2012-10-01

    To assess the value of echo-tracking technology in evaluating endothelial function of the femoral artery in patients with Grave's disease. Thirty-four patients with Grave's disease patients and 30 normal adults as controls were recruited in this study. The intima-media thickness (IMT), arterial stiffness (β), pressure strain elastic modulus (Ep), arterial compliance (AC), pulse wave conducting velocity (PWVβ) and augmentation index (AI) parameters were examined using echo-tracking technology for evaluating the right femoral arterial elasticity. Compared with the control subjects, the patients with Grave's disease showed significantly increased β, Ep, and PWVβ and significantly decreased AC (P0.05). In patients with Grave's disease, β and Ep were positively correlated with FT3, FT4, TT3, TT4, and PWVβ was positively correlated with FT3 and FT4. Echo-tracking technology can provide more accurate quantitative evidences for early diagnosis of femoral artery endothelial dysfunction in patients with Grave's disease, but the influence of procedural factors on the measurement accuracy should be considered in the evaluation.

  20. Estimating the input function non-invasively for FDG-PET quantification with multiple linear regression analysis: simulation and verification with in vivo data

    International Nuclear Information System (INIS)

    Fang, Yu-Hua; Kao, Tsair; Liu, Ren-Shyan; Wu, Liang-Chih

    2004-01-01

    A novel statistical method, namely Regression-Estimated Input Function (REIF), is proposed in this study for the purpose of non-invasive estimation of the input function for fluorine-18 2-fluoro-2-deoxy-d-glucose positron emission tomography (FDG-PET) quantitative analysis. We collected 44 patients who had undergone a blood sampling procedure during their FDG-PET scans. First, we generated tissue time-activity curves of the grey matter and the whole brain with a segmentation technique for every subject. Summations of different intervals of these two curves were used as a feature vector, which also included the net injection dose. Multiple linear regression analysis was then applied to find the correlation between the input function and the feature vector. After a simulation study with in vivo data, the data of 29 patients were applied to calculate the regression coefficients, which were then used to estimate the input functions of the other 15 subjects. Comparing the estimated input functions with the corresponding real input functions, the averaged error percentages of the area under the curve and the cerebral metabolic rate of glucose (CMRGlc) were 12.13±8.85 and 16.60±9.61, respectively. Regression analysis of the CMRGlc values derived from the real and estimated input functions revealed a high correlation (r=0.91). No significant difference was found between the real CMRGlc and that derived from our regression-estimated input function (Student's t test, P>0.05). The proposed REIF method demonstrated good abilities for input function and CMRGlc estimation, and represents a reliable replacement for the blood sampling procedures in FDG-PET quantification. (orig.)

  1. The predictive value of arterial stiffness on major adverse cardiovascular events in individuals with mildly impaired renal function

    Directory of Open Access Journals (Sweden)

    Han J

    2016-08-01

    Full Text Available Jie Han,* Xiaona Wang,* Ping Ye, Ruihua Cao, Xu Yang, Wenkai Xiao, Yun Zhang, Yongyi Bai, Hongmei Wu Department of Geriatric Cardiology, Chinese PLA General Hospital, Beijing, People’s Republic of China *These authors contributed equally to this work Objectives: Despite growing evidence that arterial stiffness has important predictive value for cardiovascular disease in patients with advanced stages of chronic kidney disease, the predictive significance of arterial stiffness in individuals with mildly impaired renal function has not been established. The aim of this study was to evaluate the predictive value of arterial stiffness on cardiovascular disease in this specific population. Materials and methods: We analyzed measurements of arterial stiffness (carotid–femoral pulse-wave velocity [cf-PWV] and the incidence of major adverse cardiovascular events (MACEs in 1,499 subjects from a 4.8-year longitudinal study. Results: A multivariate Cox proportional-hazard regression analysis showed that in individuals with normal renal function (estimated glomerular filtration rate [eGFR] ≥90 mL/min/1.73 m2, the baseline cf-PWV was not associated with occurrence of MACEs (hazard ratio 1.398, 95% confidence interval 0.748–2.613; P=0.293. In individuals with mildly impaired renal function (eGFR <90 mL/min/1.73 m2, a higher baseline cf-PWV level was associated with a higher risk of MACEs (hazard ratio 2.334, 95% confidence interval 1.082–5.036; P=0.031. Conclusion: Arterial stiffness is a moderate and independent predictive factor for MACEs in individuals with mildly impaired renal function (eGFR <90 mL/min/1.73 m2. Keywords: epidemiology, arterial stiffness, impaired renal function, predictive value, MACEs

  2. Gender Differences in the Association between Lipid Profile and Sexual Function among Patients with Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Shervin Assari

    2014-03-01

    Full Text Available Background: Although several studies have been conducted on the association between lipid profile and sexual function among men with coronary artery disease, there is a paucity of knowledge about this association among women with coronary artery disease. Objectives: Our study aimed to evaluate the link between lipid profile and sexual function in men and women with coronary artery disease. Methods: One hundred and twenty patients with documented coronary artery disease were consecutively sampled from an outpatient cardiovascular clinic. The patients were assessed for lipid profile and sexual relationship using the Relation and Sexuality Scale (RSS. In addition, the Hospital Anxiety and Depression Scale (HADS was used to measure the symptoms of anxiety and depression. The characteristics of chest pain were also measured using the Rose Angina Questionnaire. The data were analyzed through linear regression analysis. Results: This study was conducted on 91 males (75.8% and 29 females (24.2%. Multivariate analysis showed that low-density lipoprotein cholesterol was correlated with sexual function (B = 0.01, P = 0.010 and total sexual relationship (B = 0.01, P = 0.050. A correlation was also observed between the level of high-density lipoprotein and sexual frequency score (B = -0.02, P = 0.040. Gender moderated these correlations. Among males, serum cholesterol (r = 0.193, P = 0.047 and low-density lipoprotein (r = 0.224, P = 0.037 were correlated to sexual function. In females, however, low-density lipoprotein was correlated to the total sexual relationship (r = 0.426, P = 0.021 and high-density lipoprotein was correlated to sexual frequency (r = -0.334, P = 0.046. Conclusions: The findings of this study showed a relationship between lipid profile and sexual relationship among both male and female patients with coronary artery disease. The link between lipid profile and sexual function of the patients with coronary artery disease is thus beyond just

  3. Kidney transplantation improves arterial function measured by pulse wave analysis and endothelium-independent dilatation in uraemic patients despite deterioration of glucose metabolism

    DEFF Research Database (Denmark)

    Hornum, Mads; Clausen, Peter; Idorn, Thomas

    2011-01-01

    for kidney transplantation (uraemic control group, age 47 ± 11 years). Arterial function was estimated by the pulse wave velocity (PWV) of the carotid-femoral pulse wave, aortic augmentation index (AIX), flow-mediated (FMD) and nitroglycerin-induced vasodilatation (NID) of the brachial artery performed......BACKGROUND: The aim of this study is to investigate the effect of kidney transplantation on arterial function in relation to changes in glucose metabolism. METHODS: Included were 40 kidney recipients (Tx group, age 38 ± 13 years) and 40 patients without known diabetes remaining on the waiting list...... before transplantation and after 12 months. PWV recorded sequentially at the carotid and femoral artery is an estimate of arterial stiffness; AIX is an integrated index of vascular and ventricular function. FMD and NID are the dilatory capacities of the brachial artery after increased flow (endothelium...

  4. Functional and structural changes in internal pudendal arteries underlie erectile dysfunction induced by androgen deprivation

    Directory of Open Access Journals (Sweden)

    Rhéure Alves-Lopes

    2017-01-01

    Full Text Available Androgen deficiency is strongly associated with erectile dysfunction (ED. Inadequate penile arterial blood flow is one of the major causes of ED. The blood flow to the corpus cavernosum is mainly derived from the internal pudendal arteries (IPAs; however, no study has evaluated the effects of androgen deprivation on IPA′s function. We hypothesized that castration impairs IPAs reactivity and structure, contributing to ED. In our study, Wistar male rats, 8-week-old, were castrated and studied 30 days after orchiectomy. Functional and structural properties of rat IPAs were determined using wire and pressure myograph systems, respectively. Protein expression was determined by Western blot and immunohistochemistry. Plasma testosterone levels were determined using the IMMULITE 1000 Immunoassay System. Castrated rats exhibited impaired erectile function, represented by decreased intracavernosal pressure/mean arterial pressure ratio. IPAs from castrated rats exhibited decreased phenylephrine- and electrical field stimulation (EFS-induced contraction and decreased acetylcholine- and EFS-induced vasodilatation. IPAs from castrated rats exhibited decreased internal diameter, external diameter, thickness of the arterial wall, and cross-sectional area. Castration decreased nNOS and α-actin expression and increased collagen expression, p38 (Thr180/Tyr182 phosphorylation, as well as caspase 3 cleavage. In conclusion, androgen deficiency is associated with impairment of IPA reactivity and structure and increased apoptosis signaling markers. Our findings suggest that androgen deficiency-induced vascular dysfunction is an event involving hypotrophic vascular remodeling of IPAs.

  5. [Possible effect of E-selectine on structure and function of arterial vessels in patients with metabolic syndrome].

    Science.gov (United States)

    Voloshyna, O O; Lyzohub, V H; Romanenko, I M

    2007-01-01

    Endothelial dysfunction and endothelial cells activation as it was shown in patients with ischemic heart disease play important role in atherosclerosis progression and the development of cardiovascular events. Relationship between E-selectine and functional/ structural changes of the arterial vessels in patients with metabolic syndrome was not explored. We revealed that both activation of the endothelial cells and structural/functional changes of the arterial wall mostly depend on obesity and dislipedemia and in less extent on carbohydrates metabolism disorders.

  6. Effects of cranberry juice consumption on vascular function in patients with coronary artery disease123

    Science.gov (United States)

    Dohadwala, Mustali M; Holbrook, Monika; Hamburg, Naomi M; Shenouda, Sherene M; Chung, William B; Titas, Megan; Kluge, Matthew A; Wang, Na; Palmisano, Joseph; Milbury, Paul E; Blumberg, Jeffrey B; Vita, Joseph A

    2011-01-01

    Background: Cranberry juice contains polyphenolic compounds that could improve endothelial function and reduce cardiovascular disease risk. Objective: The objective was to examine the effects of cranberry juice on vascular function in subjects with coronary artery disease. Design: We completed an acute pilot study with no placebo (n = 15) and a chronic placebo-controlled crossover study (n = 44) that examined the effects of cranberry juice on vascular function in subjects with coronary artery disease. Results: In the chronic crossover study, subjects with coronary heart disease consumed a research preparation of double-strength cranberry juice (54% juice, 835 mg total polyphenols, and 94 mg anthocyanins) or a matched placebo beverage (480 mL/d) for 4 wk each with a 2-wk rest period between beverages. Beverage order was randomly assigned, and participants refrained from consuming other flavonoid-containing beverages during the study. Vascular function was measured before and after each beverage, with follow-up testing ≥12 h after consumption of the last beverage. Mean (±SD) carotid-femoral pulse wave velocity, a measure of central aortic stiffness, decreased after cranberry juice (8.3 ± 2.3 to 7.8 ± 2.2 m/s) in contrast with an increase after placebo (8.0 ± 2.0 to 8.4 ± 2.8 m/s) (P = 0.003). Brachial artery flow-mediated dilation, digital pulse amplitude tonometry, blood pressure, and carotid-radial pulse wave velocity did not change. In the uncontrolled pilot study, we observed improved brachial artery flow-mediated dilation (7.7 ± 2.9% to 8.7 ± 3.1%, P = 0.01) and digital pulse amplitude tonometry ratio (0.10 ± 0.12 to 0.23 ± 0.16, P = 0.001) 4 h after consumption of a single 480-mL portion of cranberry juice. Conclusions: Chronic cranberry juice consumption reduced carotid femoral pulse wave velocity—a clinically relevant measure of arterial stiffness. The uncontrolled pilot study suggested an acute benefit; however, no chronic effect on measures of

  7. A femoral arteriovenous shunt facilitates arterial whole blood sampling in animals

    International Nuclear Information System (INIS)

    Weber, Bruno; Burger, Cyrill; Buck, Alfred; Biro, Peter

    2002-01-01

    In this study we evaluated on-line continuous blood sampling in a femoral arteriovenous (a-v) shunt for use in quantitative tracer studies using gamma-emitting radionuclides in animals. The shunt consisted of 40 cm polyethylene tubing (PE-50) guided through a coincidence probe. Two three-way valves allowed blood pressure measurements and tracer injection. Blood flow in the shunt and the impulse response function (IRF) were assessed using heparinized human blood mixed with fluorine-18 fluorodeoxyglucose (FDG). In vivo experiments were performed in eight male rats (300-350 g) anaesthetized with halothane. In three rats, manual blood sampling was performed in parallel with on-line sampling. In another five animals, the arterial whole blood activity was recorded on-line for 40 min. For the experiments 150-180 MBq FDG was injected over 35 s. Blood flow in the shunt was 23.6, 29.2 and 42.8 ml/h at 100, 120 and 160 mmHg, respectively. The IRF was characterized by minimal dispersion (1-2 s FWHM). Deconvolution of the measured arterial input curves with the IRF changed the measured curve only minimally. Whole blood radioactivity concentration derived from manual and on-line sampling were in excellent agreement. The curves derived from on-line sampling were of high statistical quality. In conclusion, a femoral a-v shunt allows multiple manipulations such as measurement of the arterial whole blood activity, continuous blood pressure monitoring, injection of the tracer and collection of blood samples if necessary. It is not associated with blood loss if the collection of blood samples is not required. It is more convenient to use than manual sampling, the peak of the input curve is never missed and the input curves are of high statistical quality. (orig.)

  8. Pressure drop and arterial compliance - Two arterial parameters in one measurement.

    Science.gov (United States)

    Rotman, Oren M; Zaretsky, Uri; Shitzer, Avraham; Einav, Shmuel

    2017-01-04

    Coronary artery pressure-drop and distensibility (compliance) are two major, seemingly unrelated, parameters in the cardiovascular clinical setting, which are indicative of coronary arteries patency and atherosclerosis severity. While pressure drop is related to flow, and therefore serves as a functional indicator of a stenosis severity, the arterial distensibility is indicative of the arterial stiffness, and hence the arterial wall composition. In the present study, we hypothesized that local pressure drops are dependent on the arterial distensibility, and hence can provide information on both indices. The clinical significance is that a single measurement of pressure drop could potentially provide both functional and bio-mechanical metrics of lesions, and thus assist in real-time decision making prior to stenting. The goal of the current study was to set the basis for understanding this relationship, and define the accuracy and sensitivity required from the pressure measurement system. The investigation was performed using numerical fluid-structure interaction (FSI) simulations, validated experimentally using our high accuracy differential pressure measurement system. Simplified silicone mock coronary arteries with zero to intermediate size stenoses were used, and various combinations of arterial distensibility, diameter, and flow rate were simulated. Results of hyperemic flow cases were also compared to fractional flow reserve (FFR). The results indicate the potential clinical superiority of a high accuracy pressure drop-based parameter over FFR, by: (i) being more lesion-specific, (ii) the possibility to circumvent the FFR dependency on pharmacologically-induced hyperemia, and, (iii) by providing both functional and biomechanical lesion-specific information. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Image-derived input function obtained in a 3TMR-brainPET

    Energy Technology Data Exchange (ETDEWEB)

    Silva, N.A. da [Institute of Biophysics and Biomedical Engineering, University of Lisbon (Portugal); Institute of Neurosciences and Medicine - 4, Juelich (Germany); Herzog, H., E-mail: h.herzog@fz-juelich.de [Institute of Neurosciences and Medicine - 4, Juelich (Germany); Weirich, C.; Tellmann, L.; Rota Kops, E. [Institute of Neurosciences and Medicine - 4, Juelich (Germany); Hautzel, H. [Department of Nuclear Medicine (KME), University of Duesseldorf, Medical Faculty at Research Center Juelich, Juelich (Germany); Almeida, P. [Institute of Biophysics and Biomedical Engineering, University of Lisbon (Portugal)

    2013-02-21

    Aim: The combination of a high-resolution MR-compatible BrainPET insert operated within a 3 T MAGNETOM Trio MR scanner is an excellent tool for obtaining an image derived input function (IDIF), due to simultaneous imaging. In this work, we explore the possibility of obtaining an IDIF from volumes of interest (VOI) defined over the carotid arteries (CAs) using the MR data. Material and methods: FDG data from three patients without brain disorders were included. VOIs were drawn bilaterally over the CAs on a MPRAGE image using a 50% isocontour (MR50VOI). CA PET/MR co-registration was examined based on an individual and combined CA co-registration. After that, to estimate the IDIF, the MR50VOI average (IDIF-A), four hottest pixels per plane (IDIF-4H) and four hottest pixels in VOI (IDIF-4V) were considered. A model-based correction for residual partial volume effects involving venous blood samples was applied, from which partial volume (PV) and spillover (SP) coefficients were estimated. Additionally, a theoretical PV coefficient (PVt) was calculated based on MR50VOI. Results: The results show an excellent co-registration between the MR and PET, with an area under the curve ratio between both co-registration methods of 1.00±0.04. A good agreement between PV and PVt was found for IDIF-A, with PV of 0.39±0.06 and PVt 0.40±0.03, and for IDIF-4H, with PV of 0.47±0.05 and PVt 0.47±0.03. The SPs were 0.20±0.03 and 0.21±0.03 for IDIF-A and IDIF-4H, respectively. Conclusion: The integration of a high resolution BrainPET in an MR scanner allows to obtain an IDIF from an MR-based VOI. This must be corrected for a residual partial volume effect.

  10. Entrainment and phase-shifting by centrifugation abolished in mice lacking functional vestibular input

    Science.gov (United States)

    Fuller, Charles; Ringgold, Kristyn

    The circadian pacemaker can be phase shifted and entrained by appropriately timed locomotor activity, however the mechanism(s) involved remain poorly understood. Recent work in our lab has suggested the involvement of the vestibular otolith organs in activity-induced changes within the circadian timing system (CTS). For example, we have shown that changes in circa-dian period and phase in response to locomotion (wheel running) require functional macular gravity receptors. We believe the neurovestibular system is responsible for the transduction of gravitoinertial input associated with the types of locomotor activity that are known to af-fect the pacemaker. This study investigated the hypothesis that daily, timed gravitoinertial stimuli, as applied by centrifugation. would induce entrainment of circadian rhythms in only those animals with functional afferent vestibular input. To test this hypothesis, , chemically labyrinthectomized (Labx) mice, mice lacking macular vestibular input (head tilt or hets) and wildtype (WT) littermates were implanted i.p. with biotelemetry and individually housed in a 4-meter diameter centrifuge in constant darkness (DD). After 2 weeks in DD, the mice were exposed daily to 2G via centrifugation from 1000-1200 for 9 weeks. Only WT mice showed entrainment to the daily 2G pulse. The 2G pulse was then re-set to occur at 1200-1400 for 4 weeks. Only WT mice demonstrated a phase shift in response to the re-setting of the 2G pulse and subsequent re-entrainment to the new centrifugation schedule. These results provide further evidence that gravitoinertial stimuli require a functional vestibular system to both en-train and phase shift the CTS. Entrainment among only WT mice supports the role of macular gravity receptive cells in modulation of the CTS while also providing a functional mechanism by which gravitoinertial stimuli, including locomotor activity, may affect the pacemaker.

  11. Functional and cosmetic results of fingertip replantation: anastomosing only the digital artery.

    Science.gov (United States)

    Matsuzaki, Hironori; Yoshizu, Takae; Maki, Yutaka; Tsubokawa, Naoto

    2004-10-01

    In fingertip amputations, conventional stump plasty provides an almost acceptable functional result. However, replanting fingertips can preserve the nail and minimize loss of function. We investigated the functional and cosmetic results of fingertip replantation at the terminal branch of the digital artery. Outcomes were nailbed width and distal-segment length; sensory recovery; and range of motion (ROM) of thumb-interphalangeal (IP) or finger-distal interphalangeal (DIP) joints, and total active motion (TAM) of the replanted finger. Of 15 fingertips replanted after only arterial anastomosis, 13 were successful, and 12 were studied. After a median of 1.3 years, mean nailbed widths and distal-segment lengths were 95.4% and 93.0%, respectively, of the contralateral finger. Average TAM and ROM of the thumb-IP or finger-DIP joints were 92.0% and 83.0% of normal, respectively. Semmes-Weinstein results were blue (3.22 to 3.61) in 4 fingers and purple (3.84 to 4.31) in 8; the mean result from the 2-point discrimination test was 5.9 mm (range, 3 to 11 mm). Thus, amputated fingertips should be aggressively replanted.

  12. Restoration of Failed Renal Graft Function After Successful Angioplasty of Pressure-Resistant Renal Artery Stenosis Using a Cutting Balloon: A Case Report

    International Nuclear Information System (INIS)

    Peregrin, J. H.; Buergelova, M.

    2009-01-01

    This study is the report of a 37-year-old male with a transplanted kidney from a 3.5-year-old donor: the graft had two arteries transplanted with an aortic patch to an external iliac artery. Four months after transplantation, the graft function deteriorated, together with the development of hypertension. Stenosis of both graft arteries was detected and the patient was referred for angioplasty. The angiographic result was suboptimal, nevertheless, the graft function improved and was more or less stable (serum creatinine, 160-200 μmol/l) for 4 years, along with persistently difficult-to-control hypertension. Five years after transplantation, the graft function deteriorated again and severe graft artery restenosis was detected. The restenosis did not respond to dilatation, graft function failed, hypertension decompensated, and left ventricular failure developed. The patient required dialysis. A cutting balloon angioplasty opened the artery, and kidney function was restored after a few days: the serum creatinine level dropped to 140-160 μmol/l, and the glomerular filtration rate (creatinine clearance) to 0.65 ml/min/1.73 m 2 . The graft function has now been stable for more than 2 years, however, the hypertension is still difficult to control.

  13. Functional dilatation and medial remodeling of the renal artery in response to chronic increased blood flow.

    Science.gov (United States)

    Roan, Jun-Neng; Yeh, Chin-Yi; Chiu, Wen-Cheng; Lee, Chou-Hwei; Chang, Shih-Wei; Jiangshieh, Ya-Fen; Tsai, Yu-Chuan; Lam, Chen-Fuh

    2011-01-01

    Renal blood flow (RBF) is tightly regulated by several intrinsic pathways in maintaining optimal kidney blood supply. Using a rat model of aortocaval (AC) fistula, we investigated remodeling of the renal artery following prolonged increased blood flow. An AC fistula was created in the infrarenal aorta of anesthetized rats, and changes of blood flow in the renal artery were assessed using an ultrasonic flow probe. Morphological changes and expression of endothelial nitric oxide synthase and matrix metalloproteinase-2 in the remodeled renal artery were analyzed. Blood flow in the renal artery increased immediately after creation of AC fistula, but normal RBF was restored 8 weeks later. The renal artery dilated significantly 8 weeks after operation. Expression of endothelial nitric oxide synthase and matrix metalloproteinase-2 was upregulated shortly after blood flow increase, and returned to baseline levels after 3 weeks. Histological sections showed luminal dilatation with medial thickening and endothelial cell-to-smooth muscle cell attachments in the remodeled renal artery. Increased RBF was accommodated by functional dilatation and remodeling in the medial layer of the renal artery in order to restore normal blood flow. Our results provide important mechanistic insight into the intrinsic regulation of the renal artery in response to increased RBF. Copyright © 2011 S. Karger AG, Basel.

  14. Correlations Between the Gradient of Contrast Density, Evaluated by Cardio CT, and Functional Significance of Coronary Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Orzan Marius

    2016-06-01

    Full Text Available Background: Assessment of the hemodynamic significance of a coronary artery stenosis is a challenging task, being extremely important for the establishment of indication for revascularization in atherosclerotic coronary artery stenosis. The aim of this study was to evaluate the role of a new marker reflecting the functional significance of a coronary artery stenosis, represented by the attenuation degree of contrast density along the stenosis by Coronary CT.

  15. Growth hormone (GH) and atherosclerosis: changes in morphology and function of major arteries during GH treatment.

    Science.gov (United States)

    Pfeifer, M; Verhovec, R; Zizek, B

    1999-04-01

    Patients with hypopituitarism have increased carotid artery intima-media thickness and reduced arterial distensibility. The effect of 2 years of growth hormone (GH) replacement therapy on these parameters was studied in 11 GH-deficient men (age range, 24-49 years) with hypopituitarism and compared with 12 healthy, age-matched men with no evidence of pituitary or vascular disease. Before treatment the intima-media of the common carotid arteries and the carotid bifurcations were significantly thicker in patients (P < 0.001) than in the control group. Treatment with GH normalized the intima-media thickness of the common carotid artery within 6 months and of the carotid bifurcation within 3 months. The changes in intima-media thickness of the carotid artery were negatively correlated with changes in serum levels of insulin-like growth factor I during treatment. There was a significant improvement in flow-mediated, endothelium-dependent dilation of the brachial artery at 3 months, which was sustained at 6, 18 and 24 months of GH treatment (P < 0.05). Thus, GH replacement therapy in GH-deficient men reverses early morphological and functional atherosclerotic changes in major arteries, and may reduce rates of vascular morbidity and mortality.

  16. Intravascular ultrasound as a novel tool for the diagnosis and targeted treatment of functional popliteal artery entrapment syndrome

    Directory of Open Access Journals (Sweden)

    Anna E. Boniakowski, MD

    2017-06-01

    Full Text Available Functional popliteal artery entrapment syndrome can be difficult to diagnose, as the imaging modalities presently employed are designed to detect anatomic entrapment. We describe a novel imaging technique to aid in diagnosis in this cohort. A 22-year-old cyclist presented with exercise-limiting claudication. Magnetic resonance angiography with provocative maneuvers was nondiagnostic. Digital subtraction angiography revealed long-segment occlusion of the popliteal artery with plantar flexion; however, the specific site of compression remained unclear. Intravascular ultrasound allowed specific localization of compression and further confirmed the diagnosis. Thus, we report this as an adjunctive imaging modality to definitively diagnose functional popliteal artery entrapment syndrome and to assist in operative planning.

  17. Exercise training and artery function in humans: nonresponse and its relationship to cardiovascular risk factors.

    NARCIS (Netherlands)

    Green, D.J.; Eijsvogels, T.M.; Bouts, Y.M.; Maiorana, A.J.; Naylor, L.H.; Scholten, R.R.; Spaanderman, M.E.; Pugh, C.J.; Sprung, V.S.; Schreuder, T.H.; Jones, H.; Cable, T.; Hopman, M.T.E.; Thijssen, D.H.J.

    2014-01-01

    The objectives of our study were to examine 1) the proportion of responders and nonresponders to exercise training in terms of vascular function; 2) a priori factors related to exercise training-induced changes in conduit artery function, and 3) the contribution of traditional cardiovascular risk

  18. Early uneven ear input induces long-lasting differences in left-right motor function.

    Science.gov (United States)

    Antoine, Michelle W; Zhu, Xiaoxia; Dieterich, Marianne; Brandt, Thomas; Vijayakumar, Sarath; McKeehan, Nicholas; Arezzo, Joseph C; Zukin, R Suzanne; Borkholder, David A; Jones, Sherri M; Frisina, Robert D; Hébert, Jean M

    2018-03-01

    How asymmetries in motor behavior become established normally or atypically in mammals remains unclear. An established model for motor asymmetry that is conserved across mammals can be obtained by experimentally inducing asymmetric striatal dopamine activity. However, the factors that can cause motor asymmetries in the absence of experimental manipulations to the brain remain unknown. Here, we show that mice with inner ear dysfunction display a robust left or right rotational preference, and this motor preference reflects an atypical asymmetry in cortico-striatal neurotransmission. By unilaterally targeting striatal activity with an antagonist of extracellular signal-regulated kinase (ERK), a downstream integrator of striatal neurotransmitter signaling, we can reverse or exaggerate rotational preference in these mice. By surgically biasing vestibular failure to one ear, we can dictate the direction of motor preference, illustrating the influence of uneven vestibular failure in establishing the outward asymmetries in motor preference. The inner ear-induced striatal asymmetries identified here intersect with non-ear-induced asymmetries previously linked to lateralized motor behavior across species and suggest that aspects of left-right brain function in mammals can be ontogenetically influenced by inner ear input. Consistent with inner ear input contributing to motor asymmetry, we also show that, in humans with normal ear function, the motor-dominant hemisphere, measured as handedness, is ipsilateral to the ear with weaker vestibular input.

  19. Imaging of carotid artery disease: from luminology to function?

    Energy Technology Data Exchange (ETDEWEB)

    Gillard, J.H. [University Department of Radiology, Addenbrooke' s Hospital, Cambridge (United Kingdom)

    2003-10-01

    There have been tremendous advances in our ability to image atheromatous disease, particularly in the carotid artery, which is accessible and large enough to image. The repertoire of methodology available is growing, giving anatomical information on luminal narrowing which is approaching the level at which conventional carotid angiography will become very uncommon as CT and contrast-enhanced MR angiographic techniques become the norm. More exciting is the tentative ability to perform functional plaque imaging addressing enhancement patterns and macrophage activity using MR or positron-emission tomography techniques. These techniques, once rigorously evaluated, may, in addition to complex mathematical modelling of plaque, eventually allow us to assess true plaque risk. Time will best judge whether we will be able to move from the use of simple luminology to assessment of plaque function. (orig.)

  20. Imaging of carotid artery disease: from luminology to function?

    International Nuclear Information System (INIS)

    Gillard, J.H.

    2003-01-01

    There have been tremendous advances in our ability to image atheromatous disease, particularly in the carotid artery, which is accessible and large enough to image. The repertoire of methodology available is growing, giving anatomical information on luminal narrowing which is approaching the level at which conventional carotid angiography will become very uncommon as CT and contrast-enhanced MR angiographic techniques become the norm. More exciting is the tentative ability to perform functional plaque imaging addressing enhancement patterns and macrophage activity using MR or positron-emission tomography techniques. These techniques, once rigorously evaluated, may, in addition to complex mathematical modelling of plaque, eventually allow us to assess true plaque risk. Time will best judge whether we will be able to move from the use of simple luminology to assessment of plaque function. (orig.)

  1. MR velocity mapping measurement of renal artery blood flow in patients with impaired kidney function

    DEFF Research Database (Denmark)

    Cortsen, M; Petersen, L.J.; Stahlberg, F

    1996-01-01

    Renal blood flow (RBF) was measured in 9 patients with chronic impaired kidney function using MR velocity mapping and compared to PAH clearance and 99mTc-DTPA scintigraphy. An image plane suitable for flow measurement perpendicular to the renal arteries was chosen from 2-dimensional MR angiography....... MR velocity mapping was performed in both renal arteries using an ECG-triggered gradient echo pulse sequence previously validated in normal volunteers. Effective renal plasma flow was calculated from the clearance rate of PAH during constant infusion and the split of renal function was evaluated...... by 99mTc-DTPA scintigraphy. A reduction of RBF was found, and there was a significant correlation between PAH clearance multiplied by 1/(1-hematocrit) and RBF determined by MR velocity mapping. Furthermore, a significant correlation between the distribution of renal function and the percent distribution...

  2. Left ventricular diastolic function in patients with coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, P.T.

    1986-08-01

    In 302 patients with confirmed coronary disease we determined the left ventricular diastolic function with the Nuclear Stethoscope by the aid of the Peak Filling Rate (PFR) and the Time to Peak Filling Rate (TPFR). Moreover we investigated the ejection fraction (EF). 201 patients had already suffered a myocardial infarction, of these 99 an anterior wall and 102 an inferior wall infarction. The remaining 101 patients had a CAD without a history of myocardial infarction. The PFR was 2.19 +- 0.65 EDV/sec in the 99 patients after anterior wall infarction and 2.62 +- 0.85 EDV/sec in the 102 patients after inferior wall infarction and 2.79 +- 0.85 EDV/sec in 101 patients with coronary artery disease without a history of myocardial infarction. For the PFR there could be found a statistically significant difference between normal patients and patients after anterior wall infarction (p < 0.0001), normal patients and patients after inferior wall infarction (p < 0.0001) and normal patients and patients with coronary artery disease (p < 0.0001). The TPFR was 180 +- 37.5 msec after anterior - and 158 +- 50.7 msec after inferior wall infarction and 156 +- 45.2 msec in the patients with CAD without previous infarction. The left ventricular diastolic function (PFR and/or TPFR) was abnormal in 88% after anterior- and in 82% after inferior wall infarction and in 69% in coronary patients without previous myocardial infarction. In comparison with this the ejection fraction was reduced in 66% in anterior- and in 61% inferior wall infarction at rest. These results indicate that the diastolic function at rest appears to be more informative for evaluation of a left ventricular dysfunction than the systolic function at rest.

  3. Dissociation of endothelial function and arterial stiffness in nonobese women with polycystic ovary syndrome (PCOS).

    Science.gov (United States)

    Cussons, Andrea J; Watts, Gerald F; Stuckey, Bronwyn G A

    2009-12-01

    Polycystic ovary syndrome (PCOS) is associated with cardiovascular risk but it is not clear if this is independent of obesity and insulin resistance. This study therefore investigates endothelial function and arterial stiffness in nonobese, noninsulin resistant women with PCOS. This is cross-sectional case-control study. A total of 19 young women with PCOS, with body mass index (BMI) PCOS and control subjects when assessing the following clinical and biochemical variables: blood pressure, homeostasis model assessment insulin-resistance index, lipids and oestradiol. Women with PCOS had higher free androgen index scores (5.14 ± 3.47 vs. 3.25 ± 1.42, P = 0.036). The PCOS subjects had significantly lower FMD of the brachial artery compared with the controls (6.5 ± 2.9%vs. 10.5 ± 4.0%, P insulin resistance, have abnormal vascular function, but normal arterial stiffness, when compared with age and weight matched control subjects. Whether this leads to a greater risk of cardiovascular disease requires further investigation. © 2009 Blackwell Publishing Ltd.

  4. Beta-1-Selective Beta-Blockers and Cognitive Functions in Patients With Coronary Artery Disease: A Cross-Sectional Study.

    Science.gov (United States)

    Burkauskas, Julius; Noreikaite, Aurelija; Bunevicius, Adomas; Brozaitiene, Julija; Neverauskas, Julius; Mickuviene, Narseta; Bunevicius, Robertas

    2016-01-01

    The association between current beta-1-selective beta-blocker use and cognitive function was evaluated in 722 patients with coronary artery disease without dementia. Beta-1-selective beta-blocker use was associated with worse incidental learning independently of sociodemographic characteristics, clinical coronary artery disease severity, and depression/anxiety.

  5. Randomised Trial of CPAP and Vardenafil on Erectile and Arterial Function in Men with Obstructive Sleep Apnea and Erectile Dysfunction.

    Science.gov (United States)

    Melehan, Kerri L; Hoyos, Camilla M; Hamilton, Garun S; Wong, Keith K; Yee, Brendon J; McLachlan, Rob I; O'Meagher, Shamus; Celermajer, David; Ng, Martin K; Grunstein, Ronald R; Liu, Peter Y

    2018-02-01

    Erectile function is important for life satisfaction and is often impaired in men with obstructive sleep apnea (OSA). Uncontrolled studies show that treating OSA with continuous positive airway pressure (CPAP) improves erectile function. Phosphodiesterase type 5 inhibitors (e.g. vardenafil) are the first-line therapy for erectile dysfunction (ED), but may worsen OSA. To assess the effects of CPAP and vardenafil on ED. Sixty one men with moderate-to-severe OSA and ED were randomised to 12 weeks of CPAP or sham CPAP, and 10mg daily vardenafil or placebo, in a 2x2 factorial design. International Index of Erectile Function (primary endpoint), treatment and relationship satisfaction, sleep related erections, sexual function, endothelial function, arterial stiffness, quality of life, and sleep-disordered breathing. CPAP increased the frequency of sleep-related-erections, overall sexual satisfaction, and arterial stiffness but did not change erectile function or treatment satisfaction or relationship satisfaction. Vardenafil did not alter erectile function, endothelial function, arterial stiffness or sleep disordered breathing, but did improve overall self-esteem and relationship satisfaction, other aspects of sexual function and treatment satisfaction. Adherent CPAP improved erectile function, sexual desire, overall sexual, self-esteem and relationship, and treatment satisfaction, as well as sleepiness, and quality of life. Adherent vardenafil use did not consistently change nocturnal erection quality. CPAP improves overall sexual satisfaction, sleep related erections, and arterial stiffness. Low dose daily vardenafil improves certain aspects of sexual function, and did not worsen OSA. Adherent CPAP or vardenafil use further improves ED and quality of life. Copyright © 2018 Endocrine Society

  6. Surgical neuroangiography. Vol. 1: Functional anatomy of craniofacial arteries

    International Nuclear Information System (INIS)

    Lasjaunias, P.; Berenstein, A.

    1987-01-01

    The contents of this book are: Arterial Anatomy: Introduction. - The Internal Maxillary System. - The Pharyngo-occipital System. - The Upper Cervical Vertebral Column: The Cervical Arteries. - The Musculocutaneous Elements of the Head and Mouth. - Thyrolaryngeal Arteries. - The Transosseous Peripheral Nervous System Arterial Supply. - Dangerous Vessels. - Collateral Circulation. - The Pharyngoocipital Collateral Pattern. - The Internal Maxillary Collateral Pattern. - The Linguofacial Collateral Pattern. - Multiple Constraints and Chronology of the Collateral Response. - Angiographic Protocols. - Angiographic Protocol of the Parasellar Region. - Angiographic Protocol of the Posterior Base of the Skull. - Angiographic Protocol of the Carotid Region. - Angiographic Protocol of the Nasomaxillaary Region. - Angiographic Protocol of the Maxillomandibular Region. - Angiographic Protocol of the Temporofacial and Scalp Region. - Angiographic Protocol of the Thyrolaryngeal Region. - References. - Subject Index

  7. Determination of bilateral symmetry of carotid artery structure and function in children and adolescents

    Directory of Open Access Journals (Sweden)

    Uithoven KE

    2017-01-01

    Full Text Available Katelyn E Uithoven,1 Justin R Ryder,2 Roland Z Brown,3 Kyle D Rudser,3 Nicholas G Evanoff,1 Donald R Dengel,1,2 Aaron S Kelly2,4 1School of Kinesiology, University of Minnesota, 2Department of Pediatrics, University of Minnesota Medical School, 3Division of Biostatistics, School of Public Health, University of Minnesota, 4Department of Medicine, University of Minnesota Medical School, Minneapolis, MN, USA Abstract: The carotid artery represents an ideal location for noninvasive assessment of subclinical atherosclerosis in youth. Examination of arterial structure and function is generally conducted in the left common carotid. However, if the left common carotid is inaccessible or provides a poor acoustic window, it is unknown if the right common carotid can provide comparable values. The symmetry of carotid arteries in youth with high-resolution ultrasound was compared. Participants (N=230 [121 females], 13.8±2.9 years old were assessed for carotid intima media thickness (cIMT, carotid lumen diameter (cLD, carotid incremental elastic modulus (cIEM, carotid diameter compliance (cDC, carotid cross-sectional compliance (cCSC, carotid diameter distensibility (cDD, and carotid cross-sectional distensibility (cCSD. No significant differences (P>0.05 all were found for cIMT (0.49±0.09 vs 0.49±0.08 mm, cIEM (1095±382 vs 1116±346 mmHg, cDC (0.01±0.0 vs 0.01±0.0 mm/mmHg, cCSC (0.01±0.001/mmHg vs 0.01±0.001/mmHg, cDD (14.0%±3.16% vs 13.7%±3.18%, and cCSD (30.1%±7.37% vs 29.4%±7.36%. Significant differences were found for cLD (6.06±0.62 mm vs 6.33±0.64 mm, P<0.001. The majority of measures for arterial structure and function are comparable between the left and right common carotid arteries. There were differences present for cLD; however, these discrepancies are likely due to anatomical differences between the left and right common carotid arteries. Therefore, if the left common carotid is unable to be assessed properly, the right common

  8. Use of wave intensity analysis of carotid arteries in identifying and monitoring left ventricular systolic function dynamics in rabbits.

    Science.gov (United States)

    Zhang, Hui; Zheng, Rongqin; Qian, Xiaoxian; Zhang, Chengxi; Hao, Baoshun; Huang, Zeping; Wu, Tao

    2014-03-01

    Wave intensity analysis (WIA) of the carotid artery was conducted to determine the changes that occur in left ventricular systolic function after administration of doxorubicin in rabbits. Each randomly selected rabbit was subject to routine ultrasound, WIA of the carotid artery, cardiac catheterization and pathologic examination every week and was followed for 16 wk. The first positive peak (WI1) of the carotid artery revealed that left ventricular systolic dysfunction occurred earlier than conventional indexes of heart function. WI1 was highly, positively correlated with the maximum rate of rise in left ventricular pressure in cardiac catheterization (r = 0.94, p function, and the result is highly consistent with cardiac catheterization findings and the apoptosis index of myocardial cells. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. Modification of sympathetic neuronal function in the rat tail artery by dietary lipid treatment

    International Nuclear Information System (INIS)

    Panek, R.L.; Dixon, W.R.; Rutledge, C.O.

    1985-01-01

    The effect of dietary lipid treatment on sympathetic neuronal function was examined in isolated perfused tail arteries of adult rats. The hypothesis that dietary manipulations alter the lipid environment of receptor proteins which may result in the perturbation of specific membrane-associated processes that regulate peripheral adrenergic neurotransmission in the vasculature was the basis for this investigation. In the present study, rats were fed semisynthetic diets enriched in either 16% coconut oil (saturated fat) or 16% sunflower oil (unsaturated fat). The field stimulation-evoked release of endogenous norepinephrine and total 3 H was decreased significantly in rats receiving the coconut oil diet when compared to either sunflower oil- or standard lab chow-fed rats. Norepinephrine content in artery segments from coconut oil-treated rats was significantly higher compared to either sunflower oil- or standard lab chow-fed rats. Tail arteries from rats receiving the coconut oil diet displayed significantly lower perfusion pressure responses to nerve stimulation at all frequencies tested when compared to the sunflower oil- or standard lab chow-fed rats. Vasoconstrictor responses of perfused tail arteries exposed to exogenous norepinephrine resulted in an EC50 for norepinephrine that was not changed by the dietary treatment, but adult rats receiving the sunflower oil diet displayed a significantly greater maximum response to exogenous norepinephrine (10(-5) M) compared to arteries from either coconut oil- or standard lab chow-fed rats

  10. Interventional treatment of arterial complications in post renal transplantation

    International Nuclear Information System (INIS)

    Qian Xiaojun; Dai Dingke; Zhai Renyou

    2004-01-01

    Objective: To report our experience of interventional procedure for arterial complications in post renal transplantation and to evaluate its clinical value. Methods: In a retrospective analysis of renal transplantations in our center, 52 cases of renal allograft artery abnormalities had taken angiography. Interventional procedure included transluminal angioplasty of arterial stenoses, treatment of arterial occlusion, and embolization of pseudoaneurysm. Results: Renal allograft artery abnormalities included artery stenosis (n=21), artery thrombosis (n=13) and embolision (n=1), renal artery pseudoaneurysms (n=2), and decrease of renal artery flow (n=3). Of the 21 artery stenosis, 2 grafts with artery stenosis were lost because the stenosis could not be corrected, and 3 with mild stenosis received no treatment. Another 16 accepted renal artery angioplasty (balloon dilation, n=12, and stent implantation, n=4). 14 achieved long-term allograft function. 1 graft was lost because renal function failed to recover. Restenosis occurred in one stent implantation, and lost the allograft function after secondary dilation. 13 cases received thrombolytic therapy through artery catheter for thrombosis and 9 achieved long-term allograft function. Thrombolyses failed in 3 cases, and renal function failed to recover in 1 case. One pseudoaneurysm received stent implantation after embolization, and got a short-term allograft function. The other one received allograft excision. Conclusion: Intravascular interventional therapy will be the first-line therapy for any indications of complication in post renal transplantation, and it can surely save the kidney in a majority of instances. (authors)

  11. Ambulatory arterial stiffness index in chronic kidney disease stage 2-5. Reproducibility and relationship with pulse wave parameters and kidney function

    DEFF Research Database (Denmark)

    Boesby, Lene; Thijs, Lutgarde; Elung-Jensen, Thomas

    2012-01-01

    Arterial stiffness contributes to the increased cardiovascular risk in patients with chronic kidney disease (CKD). Reproducible and easily obtainable indices of arterial stiffness are needed in order to monitor therapeutic strategies. The ambulatory arterial stiffness index (AASI) has been propos...... as such a marker. The present study investigated the day-to-day reproducibility of AASI in CKD stage 2-5 and its relationship with other markers of arterial stiffness as well as with kidney function....

  12. Arterial And Ventricular Elastance And Ventriculo-arterial Coupling In Asthmatic Children

    International Nuclear Information System (INIS)

    Ozkan, E. A.; Gecit, A.; Beysel, P.

    2016-01-01

    Objective: To compare arterial and ventricular end-systolic elastance and ventriculo-arterial coupling between asthma and healthy children and correlate these all three parameters with pulmonary function tests in subjects with asthma. Study Design: Across-sectional analytical study. Place and Duration of Study: Department of Pediatrics, Bozok University Medical Faculty,Yozgat, Turkey, from January 2012 to November 2014. Methodology: Transthoracic and Doppler echocardiography and pulmonary function tests in patients with asthma aged 7 - 12 years and control subjects. Forty stable asthma patients on prophylactic inhaled corticosteroids and 97 healthy subjects were investigated. Both groups were matched for age, gender, blood pressure, heart rate, body surface area, echocardiographic parameters and pulmonary function tests. Results: There was no difference regarding left ventricular elastance at end-systole derived by single beat/body surface area (Ees(sb)/BSA) between asthmatic patients and healthy children (2.59 ±1.29 mmHg/ml/m2, 2.43 ±1.28 mmHg/ml/m2 respectively, p=0.504), arterial elastance/BSA(Ea/BSA) (2.10 ±0.97, 1.75 ±0.89 respectively, p=0.041), and ventriculoarterial coupling (VAC) (0.83 ±0.13, 0.74 ±0.13, respectively, p < 0.001) were higher in asthmatic group than controls. There was no correlation between Ea, Ees (sb), VAC and pulmonary function tests. Conclusion: Arterial elastance increase and stiffness decrease in asthmatic patients. This may be due to using prophylactic inhaled corticosteroids. Using inhaled corticosteroids have protective effects against atherosclerosis. As a result of this higher arterial elastance, asthmatic children had higher VAC resulting in less efficient cardiovascular function. (author)

  13. Could infarct location predict the long-term functional outcome in childhood arterial ischemic stroke?

    Directory of Open Access Journals (Sweden)

    Mauricio López-Espejo

    Full Text Available ABSTRACT Objective: To explore the influence of infarct location on long-term functional outcome following a first-ever arterial ischemic stroke (AIS in non-neonate children. Method: The MRIs of 39 children with AIS (median age 5.38 years; 36% girls; mean follow-up time 5.87 years were prospectively evaluated. Infarct location was classified as the absence or presence of subcortical involvement. Functional outcome was measured using the modified Rankin scale (mRS for children after the follow-up assessment. We utilized multivariate logistic regression models to estimate the odds ratios (ORs for the outcome while adjusting for age, sex, infarct size and middle cerebral artery territory involvement (significance < 0.05. Results: Both infarcts ≥ 4% of total brain volume (OR 9.92; CI 1.76 – 55.9; p 0.009 and the presence of subcortical involvement (OR 8.36; CI 1.76 – 53.6; p 0.025 independently increased the risk of marked functional impairment (mRS 3 to 5. Conclusion: Infarct extension and location can help predict the extent of disability after childhood AIS.

  14. Coronary Flow Reserve Predicts Cardiopulmonary Fitness in Patients with Coronary Artery Disease Independently of Systolic and Diastolic Function

    DEFF Research Database (Denmark)

    Snoer, Martin; Olsen, Rasmus Huan; Monk-Hansen, Tea

    2014-01-01

    Aims Despite revascularization and optimal medical treatment, patients with coronary artery disease (CAD) have reduced exercise capacity. In the absence of coronary artery stenosis, coronary flow reserve (CFR) is a measure of coronary microvascular function, and a marker of future poor outcome...... in CAD patients. The aim of this study was to examine the relationship among CFR, systolic and diastolic function, peripheral vascular function, and cardiopulmonary fitness in CAD patients. Methods and Results Forty patients with median left ventricular ejection fraction (LVEF) 49 (interquartile 46....... Conclusions Coronary flow reserve measured noninvasively predicts cardiopulmonary fitness independently of resting systolic and diastolic function in CAD patients, indicating that cardiac output during maximal exercise is dependent on the ability of the coronary circulation to adapt to the higher metabolic...

  15. Functional end-arterial circulation of the choroid assessed by using fat embolism and electric circuit simulation.

    Science.gov (United States)

    Lee, Ji Eun; Ahn, Ki Su; Park, Keun Heung; Pak, Kang Yeun; Kim, Hak Jin; Byon, Ik Soo; Park, Sung Who

    2017-05-30

    The discrepancy in the choroidal circulation between anatomy and function has remained unsolved for several decades. Postmortem cast studies revealed extensive anastomotic channels, but angiographic studies indicated end-arterial circulation. We carried out experimental fat embolism in cats and electric circuit simulation. Perfusion defects were observed in two categories. In the scatter perfusion defects suggesting an embolism at the terminal arterioles, fluorescein dye filled the non-perfused lobule slowly from the adjacent perfused lobule. In the segmental perfusion defects suggesting occlusion of the posterior ciliary arteries, the hypofluorescent segment became perfused by spontaneous resolution of the embolism without subsequent smaller infarction. The angiographic findings could be simulated with an electric circuit. Although electric currents flowed to the disconnected lobule, the level was very low compared with that of the connected ones. The choroid appeared to be composed of multiple sectors with no anastomosis to other sectors, but to have its own anastomotic arterioles in each sector. Blood flows through the continuous choriocapillaris bed in an end-arterial nature functionally to follow a pressure gradient due to the drainage through the collector venule.

  16. CARDIAC TRANSPLANT REJECTION AND NON-INVASIVE COMON CAROTID ARTERY WALL FUNCTIONAL INDICES

    Directory of Open Access Journals (Sweden)

    A. O. Shevchenko

    2015-01-01

    Full Text Available Allograft rejection would entail an increase in certain blood biomarkers and active substances derived from activated inflammatory cells which could influence entire vascular endothelial function and deteriorate arterial wall stiffness. We propose that carotid wall functional indices measured with non-invasive ultrasound could we valuable markers of the subclinical cardiac allograft rejection. Aim. Our goal was to analyze the clinical utility of functional common carotid wall (CCW variables measured with high-resolution Doppler ultrasound as a non-invasive screening tool for allograft rejection in cardiac transplant patients (pts. Methods. One hundred and seventy one pts included 93 cardiac recipients, 30 dilated cardiomyopathy waiting list pts, and 48 stable coronary artery disease (SCAD pts without decompensated heart failure were included. Along with resistive index (Ri, pulsative index (Pi, and CCW intima-media thickness (IMT, CCW rigidity index (iRIG was estimated using empirical equation. Non-invasive evaluation was performed in cardiac transplant recipients prior the endomyo- cardial biopsy. Results. Neither of Ri, Pi, or CCW IMT were different in studied subgroups. iRIG was signifi- cantly lower in SCAD pts when compared to the dilated cardiomyopathy subgroup. The later had similar values with cardiac transplant recipients without rejection. Antibody-mediated and cellular rejection were found in 22 (23.7% and 17 (18.3% cardiac recipients, respectively. Mean iRIG in pts without rejection was significantly lower in comparison to antibody-mediated rejection and cell-mediated (5514.7 ± 2404.0 vs 11856.1 ± 6643.5 and 16071.9 ± 10029.1 cm/sec2, respectively, p = 0.001. Area under ROC for iRIG was 0.90 ± 0.03 units2. Analysis showed that iRIG values above estimated treshold 7172 cm/sec2 suggested relative risk of any type of rejection 17.7 (95%CI = 6.3–49.9 sensitivity 80.5%, specificity – 81.1%, negative predictive value – 84

  17. [Analysis of variability of cardiac rhythm and sexual function in men with arterial hypertension during therapy with biosporolol and nebivolol].

    Science.gov (United States)

    Nurmamedova, G S; Mustafaev, I I

    2012-01-01

    The aim of the work was to study effect of bisoprolol and nebivolol therapy on the sexual function of men with AH. 20 men aged 35-55 (48 +/- 3.5) yr with grade I and II AH received either drug for 2 months. Cardiac rhythm variability (CRV) was estimated in the end of the 4-week placebo period and after 2-month monotherapy. Dopplerography of penile arteries and a questionnaire study (as described by Vasilchenko) were conducted. Both drugs significantly increased the tone of the parasympathetic component of the vegetative nervous system, improved systolic blood flow in cavernous and dorsal arteries. The questionnaire study failed to revel significant changes of the sexual function. It is concluded that biosporolol and nebivolol did not compromise the sexual function of men with AH; they improve spectral CRV characteristics and blood flow in cavernous arteries.

  18. Modeling DPOAE input/output function compression: comparisons with hearing thresholds.

    Science.gov (United States)

    Bhagat, Shaum P

    2014-09-01

    Basilar membrane input/output (I/O) functions in mammalian animal models are characterized by linear and compressed segments when measured near the location corresponding to the characteristic frequency. A method of studying basilar membrane compression indirectly in humans involves measuring distortion-product otoacoustic emission (DPOAE) I/O functions. Previous research has linked compression estimates from behavioral growth-of-masking functions to hearing thresholds. The aim of this study was to compare compression estimates from DPOAE I/O functions and hearing thresholds at 1 and 2 kHz. A prospective correlational research design was performed. The relationship between DPOAE I/O function compression estimates and hearing thresholds was evaluated with Pearson product-moment correlations. Normal-hearing adults (n = 16) aged 22-42 yr were recruited. DPOAE I/O functions (L₂ = 45-70 dB SPL) and two-interval forced-choice hearing thresholds were measured in normal-hearing adults. A three-segment linear regression model applied to DPOAE I/O functions supplied estimates of compression thresholds, defined as breakpoints between linear and compressed segments and the slopes of the compressed segments. Pearson product-moment correlations between DPOAE compression estimates and hearing thresholds were evaluated. A high correlation between DPOAE compression thresholds and hearing thresholds was observed at 2 kHz, but not at 1 kHz. Compression slopes also correlated highly with hearing thresholds only at 2 kHz. The derivation of cochlear compression estimates from DPOAE I/O functions provides a means to characterize basilar membrane mechanics in humans and elucidates the role of compression in tone detection in the 1-2 kHz frequency range. American Academy of Audiology.

  19. Angiographic predictors of 3-year patency of bypass grafts implanted on the right coronary artery system: a prospective randomized comparison of gastroepiploic artery, saphenous vein, and right internal thoracic artery grafts.

    Science.gov (United States)

    Glineur, David; D'hoore, William; de Kerchove, Laurent; Noirhomme, Philippe; Price, Joel; Hanet, Claude; El Khoury, Gebrine

    2011-11-01

    Saphenous vein, in situ right gastroepiploic artery, and right internal thoracic artery grafts are routinely used to revascularize the right coronary artery. Little is known about the predictive value of objective preoperative angiographic parameters on midterm graft patency. We prospectively enrolled 210 consecutive patients undergoing coronary revascularization. Revascularization of the right coronary artery was randomly performed with the saphenous vein grafts in 81 patients and the right gastroepiploic artery in 92 patients. During the same study period, 37 patients received right coronary artery revascularization with the right internal thoracic artery used in a Y-composite fashion. All patients underwent a protocol-driven coronary angiogram 3 years after surgery. Preoperative angiographic parameters included minimum lumen diameter percent stenosis measured by quantitative angiography. A graft was considered "not functional" with patency scores of 0 to 2 and "functional" with patency scores of 3 or 4. Angiographic follow-up was 100% complete. A significant difference in the distribution of flow patterns was observed in the 3 groups. In multivariate analysis, the use of a saphenous vein graft was associated with superior graft functionality compared with the other conduits (odds ratio, 6.1; 95% confidence interval, 2.4-15). Graft function was negatively influenced by the minimum lumen diameter (odds ratio, 0.11; confidence interval, 0.05-0.25). In the right gastroepiploic artery and right internal thoracic artery groups, the proportion of functional grafts was higher when the minimum lumen diameter was below a threshold value in the third minimum lumen diameter quartile (0.64-1.30 mm). Preoperative angiography predicts graft patency in the right gastroepiploic artery and right internal thoracic artery, whereas the flow pattern in saphenous vein grafts is significantly less influenced by quantitative angiographic parameters. Copyright © 2011 The American

  20. Comparing the effects of a cardiac rehabilitation program on functional capacity of obese and non-obese women with coronary artery disease

    Directory of Open Access Journals (Sweden)

    Masoumeh Sadeghi

    2012-06-01

    Full Text Available    BACKGROUND: Obesity and sedentary lifestyle are known as important risk factors of coronary artery disease. The prevalence of obesity has increased among both men and women in the world. Therefore, the present study tried to evaluate the effectiveness of a cardiac rehabilitation program on functional capacity and body mass index (BMI in obese and non-obese women with coronary artery disease.    METHODS: In an observational study during 2000-11, we evaluated a total of 205 women with coronary artery disease who referred to the cardiac rehabilitation unit of Isfahan Cardiovascular Research Institute, Isfahan, Iran. BMI and functional capacity of each patient were assessed before and after the program. The patients were categorized as obese or non-obese based on their BMI. All participants completed the full course of the program. Data was analyzed by independent t-test and paired t-test in SPSS15.    RESULTS: Our finding showed that an 8-week cardiac rehabilitation program had significant effects on functional capacity in obese and non-obese female patients (P < 0.01 for both. The program also resulted in BMI improvements in both groups (P < 0.01 for both. Comparing the changes in the two groups did not reveal any significant differences in functional capacity. However, the two groups were significantly different in terms of BMI changes.    CONCLUSION: Cardiac rehabilitation programs are a major step in restoration of functional capacity and improvement of BMI in obese and non-obese women with coronary artery disease.         Keywords: Cardiac Rehabilitation Program, Coronary Artery Disease, Obesity, Functional Capacity, Body Mass Index.

  1. Association of thyroid function with arterial pressure in normotensive and hypertensive euthyroid individuals: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Saltiki Katerina

    2008-09-01

    Full Text Available Abstract Background Overt hypothyroidism has been associated with arterial hypertension and increased arterial stiffness. Results in euthyroid individuals have been conflicting. We investigated associations of thyroid function with systolic (SAP and diastolic (DAP arterial pressure in euthyroid subjects. Methods 311 euthyroid individuals (185 women, mean age 43.9 ± 9 without a history of diabetes attending a preventive medicine program were examined. Subjects receiving thyroxine (10.6% were excluded; 19.3% had hypertension, 43% had a family history for hypertension. TSH, fT4, thyroid autoantibodies, insulin, glucose were measured. The "fT4.TSH product", which has been suggested as a T4 resistance-index, was calculated. Results TSH range was 0.1–8, median 1.4 mU/L, fT4 range was 11.5–25.2 pmol/L, median 17.4. TSH and the "fT4.TSH product" were positively associated with DAP (p 2 mU/L (35.3% vs 21.3%, p = 0.045. Conclusion In euthyroid individuals the association of thyroid function with diastolic arterial pressure remains significant even when a stricter "normal range" for TSH levels is considered. The "freeT4.TSH" product appears to be an even stronger predictor of DAP, independently of HOMA insulin resistance index and obesity.

  2. The atypical structure and function of newborn arterial endothelium is mediated by Rho/Rho kinase signaling.

    Science.gov (United States)

    Flavahan, Sheila; Flavahan, Nicholas A

    2014-08-15

    Endothelium of fetal or newborn arteries is atypical, displaying actin stress fibers and reduced nitric oxide (NO)-mediated dilatation. This study tested the hypothesis that Rho/Rho kinase signaling, which promotes endothelial stress fibers and inhibits endothelial dilatation, contributed to this phenotype. Carotid arteries were isolated from newborn [postnatal day 1 (P1)], P7, and P21 mice. Endothelial dilatation to acetylcholine (pressure myograph) was minimal at P1, increased at P7, and further increased at P21. Inhibition of Rho (C3 transferase) or Rho kinase (Y27632, fasudil) significantly increased dilatation to acetylcholine in P1 arteries but had no effect in P7 or P21 arteries. After inhibition of NO synthase (N(G)-nitro-l-arginine methyl ester), Rho kinase inhibition no longer increased acetylcholine responses in P1 arteries. Rho kinase inhibition did not affect dilatation to the NO donor DEA-NONOate. The endothelial actin cytoskeleton was labeled with phalloidin and visualized by laser-scanning microscopy. In P1 arteries, the endothelium had prominent transcytoplasmic stress fibers, whereas in P7 and P21 arteries, the actin fibers had a significantly reduced intensity and were restricted to cell borders. Phosphorylation of myosin light chains, a Rho kinase substrate, was highest in P1 endothelium and significantly reduced in P7 and P21 endothelium (laser-scanning microscopy). In P1 arteries, inhibition of Rho (C3 transferase) or Rho kinase (Y27632) significantly reduced the intensity of actin fibers, which were restricted to cell borders. Similarly, in P1 arteries, Rho inhibition significantly reduced endothelial levels of phosphorylated myosin light chains. These results indicate that the atypical function and morphology of newborn endothelium is mediated by Rho/Rho kinase signaling. Copyright © 2014 the American Physiological Society.

  3. Functional Analysis of a Novel Genome-Wide Association Study Signal in SMAD3 That Confers Protection From Coronary Artery Disease.

    Science.gov (United States)

    Turner, Adam W; Martinuk, Amy; Silva, Anada; Lau, Paulina; Nikpay, Majid; Eriksson, Per; Folkersen, Lasse; Perisic, Ljubica; Hedin, Ulf; Soubeyrand, Sebastien; McPherson, Ruth

    2016-05-01

    A recent genome-wide association study meta-analysis identified an intronic single nucleotide polymorphism in SMAD3, rs56062135C>T, the minor allele (T) which associates with protection from coronary artery disease. Relevant to atherosclerosis, SMAD3 is a key contributor to transforming growth factor-β pathway signaling. Here, we seek to identify ≥1 causal coronary artery disease-associated single nucleotide polymorphisms at the SMAD3 locus and characterize mechanisms whereby the risk allele(s) contribute to coronary artery disease risk. By genetic and epigenetic fine mapping, we identified a candidate causal single nucleotide polymorphism rs17293632C>T (D', 0.97; r(2), 0.94 with rs56062135) in intron 1 of SMAD3 with predicted functional effects. We show that the sequence encompassing rs17293632 acts as a strong enhancer in human arterial smooth muscle cells. The common allele (C) preserves an activator protein (AP)-1 site and enhancer function, whereas the protective (T) allele disrupts the AP-1 site and significantly reduces enhancer activity (Pto the (C) allele. We show that rs17293632 is an expression quantitative trait locus for SMAD3 in blood and atherosclerotic plaque with reduced expression of SMAD3 in carriers of the protective allele. Finally, siRNA knockdown of SMAD3 in human arterial smooth muscle cells increases cell viability, consistent with an antiproliferative role. The coronary artery disease-associated rs17293632C>T single nucleotide polymorphism represents a novel functional cis-acting element at the SMAD3 locus. The protective (T) allele of rs17293632 disrupts a consensus AP-1 binding site in a SMAD3 intron 1 enhancer, reduces enhancer activity and SMAD3 expression, altering human arterial smooth muscle cell proliferation. © 2016 American Heart Association, Inc.

  4. Cardiovascular Structure and Function in Children With Middle Aortic Syndrome and Renal Artery Stenosis.

    Science.gov (United States)

    Rumman, Rawan K; Slorach, Cameron; Hui, Wei; Matsuda-Abedini, Mina; Langlois, Valerie; Radhakrishnan, Seetha; Lorenzo, Armando J; Amaral, Joao; Mertens, Luc; Parekh, Rulan S

    2017-12-01

    Middle aortic syndrome (MAS) is a narrowing of the abdominal aorta, often in conjunction with renal artery stenosis (RAS). Structure and function of the cardiovascular system are not well understood. In a prospective cross-sectional study, 35 children with MAS or RAS or both (MAS/RAS) were compared with 140 age-, sex-, and body surface area-matched healthy children. Vascular assessment included carotid intima-media thickness and carotid distensibility using B-mode ultrasound and central and peripheral pulse wave velocities using applanation tonometry. Left ventricular structure and function were assessed by 2-dimensional and speckle-tracking echocardiography. Children with MAS or RAS were 12.5±3.0 years old at enrollment, and 50% were men. Carotid intima-media thickness (0.54±0.10 versus 0.44±0.05 mm; P function (lower E/a ratio and lower e' velocities). Systolic parameters, including ejection fraction, global longitudinal and circumferential strain, were similar to controls. Our findings demonstrate that children with MAS or RAS have evidence of carotid and left ventricular remodeling, without peripheral arterial involvement, which suggests a localized disease process. Left ventricular systolic function is preserved; however, subtle changes in diastolic function are observed. Carotid vessel changes are consistent with a 5- to 10-year aging, which underscores the importance of blood pressure control. © 2017 American Heart Association, Inc.

  5. Evaluation of ventricular function in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Rocco, T.P.; Dilsizian, V.; Fischman, A.J.; Strauss, H.W.

    1989-01-01

    The recent expansion of interventional cardiovascular technologies has stimulated a concomitant expansion of noninvasive cardiac studies, both to assist in diagnosis and to evaluate treatment outcomes. Radionuclide ventricular function studies provide a reliable, reproducible means to quantify global left ventricular systolic performance, a critical determinant of prognosis in patients with cardiovascular disease. In addition, the ability to evaluate regional left ventricular wall motion and to assess ventricular performance during exercise have secured a fundamental role for such studies in the screening and treatment of patients with coronary artery disease. Radionuclide techniques have been extended to the evaluation of left ventricular relaxation/filling events, left ventricular systolic/diastolic function in the ambulatory setting, and with appropriate technical modifications, to the assessment of right ventricular performance at rest and with exercise. As a complement to radionuclide perfusion studies, cardiac blood-pool imaging allows for thorough noninvasive description of cardiac physiology and function in both normal subjects and in patients with a broad range of cardiovascular diseases. 122 references

  6. Parametrically defined cerebral blood vessels as non-invasive blood input functions for brain PET studies

    International Nuclear Information System (INIS)

    Asselin, Marie-Claude; Cunningham, Vincent J; Amano, Shigeko; Gunn, Roger N; Nahmias, Claude

    2004-01-01

    A non-invasive alternative to arterial blood sampling for the generation of a blood input function for brain positron emission tomography (PET) studies is presented. The method aims to extract the dimensions of the blood vessel directly from PET images and to simultaneously correct the radioactivity concentration for partial volume and spillover. This involves simulation of the tomographic imaging process to generate images of different blood vessel and background geometries and selecting the one that best fits, in a least-squares sense, the acquired PET image. A phantom experiment was conducted to validate the method which was then applied to eight subjects injected with 6-[ 18 F]fluoro-L-DOPA and one subject injected with [ 11 C]CO-labelled red blood cells. In the phantom study, the diameter of syringes filled with an 11 C solution and inserted into a water-filled cylinder were estimated with an accuracy of half a pixel (1 mm). The radioactivity concentration was recovered to 100 ± 4% in the 8.7 mm diameter syringe, the one that most closely approximated the superior sagittal sinus. In the human studies, the method systematically overestimated the calibre of the superior sagittal sinus by 2-3 mm compared to measurements made in magnetic resonance venograms on the same subjects. Sources of discrepancies related to the anatomy of the blood vessel were found not to be fundamental limitations to the applicability of the method to human subjects. This method has the potential to provide accurate quantification of blood radioactivity concentration from PET images without the need for blood samples, corrections for delay and dispersion, co-registered anatomical images, or manually defined regions of interest

  7. Impact of arterial occlusion during partial nephrectomy on residual renal function. An evaluation with {sup 99m}technetium-dimercaptosuccinic acid scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Tsunenori; Nakazawa, Hayakazu; Ito, Fumio; Onitsuka, Shiro; Ryoji, Osamu; Yago, Rie; Hashimoto, Yasunobu; Toma, Hiroshi [Tokyo Women' s Medical Coll. (Japan)

    2002-08-01

    Partial nephrectomy (PNx) has been performed with temporary renal arterial occlusion and in situ renal hypothermia (conventional PNx). However, the impact of temporary renal arterial occlusion on residual renal function has not been well assessed. To address this question, we performed renal scintigraphy with {sup 99m}technetium-dimercaptosuccinic acid (DMSA) for the quantitative measurement of postoperative residual renal function after conventional PNx and partial nephrectomy without arterial occlusion (non-clamping PNx). Thirty-four patients underwent postoperative DMSA scintigraphy after PNx for renal cell carcinoma. No obvious difference in preoperative renal function between the diseased kidney and the contralateral kidney was found in any of the patients. Of these patients, 24 underwent conventional PNx, and 10 underwent non-clamping PNx. Residual renal function was evaluated using the relative DMSA uptake of the operated kidney. The relative DMSA uptake of the operated kidney was 39.9{+-}7.3% (25.1-58.8) after conventional PNx compared to 34.8{+-}8.9% (13.5-45.5) after non-clamping PNx. This difference was not statistically significant (P=0.15). Total ischemic time during conventional PNx had no adverse influence on the residual renal function. In the analysis of the other determinant factors influencing residual renal function, tumor size was the only significant factor that inversely correlated with the relative DMSA uptake. Our results showed that arterial clamping during PNx has no negative impact on the functional residual capacity as long as in situ renal hypothermia is adequately performed. (author)

  8. Comparing model-based and model-free analysis methods for QUASAR arterial spin labeling perfusion quantification.

    Science.gov (United States)

    Chappell, Michael A; Woolrich, Mark W; Petersen, Esben T; Golay, Xavier; Payne, Stephen J

    2013-05-01

    Amongst the various implementations of arterial spin labeling MRI methods for quantifying cerebral perfusion, the QUASAR method is unique. By using a combination of labeling with and without flow suppression gradients, the QUASAR method offers the separation of macrovascular and tissue signals. This permits local arterial input functions to be defined and "model-free" analysis, using numerical deconvolution, to be used. However, it remains unclear whether arterial spin labeling data are best treated using model-free or model-based analysis. This work provides a critical comparison of these two approaches for QUASAR arterial spin labeling in the healthy brain. An existing two-component (arterial and tissue) model was extended to the mixed flow suppression scheme of QUASAR to provide an optimal model-based analysis. The model-based analysis was extended to incorporate dispersion of the labeled bolus, generally regarded as the major source of discrepancy between the two analysis approaches. Model-free and model-based analyses were compared for perfusion quantification including absolute measurements, uncertainty estimation, and spatial variation in cerebral blood flow estimates. Major sources of discrepancies between model-free and model-based analysis were attributed to the effects of dispersion and the degree to which the two methods can separate macrovascular and tissue signal. Copyright © 2012 Wiley Periodicals, Inc.

  9. [Effect of monotherapy with nebivolol, bisoprolol, carvedilol on the state of vegetative nervous system and sexual function in men with arterial hypertension].

    Science.gov (United States)

    Mustafaev, I I; Nurmamedova, G S

    2013-01-01

    Aim of the study was to assess effect of monotherapy with nebivolol, bisoprolol, carvedilol for 2 months on sexual function in men with arterial hypertension (AH). Men with 1-2 degree of AH (n=75, age 35-55 years, mean age 48+/-3,5 years) received monotherapy with these drugs for 2 months. Registration of parameters of heart rate variability (HRV), Dopplerography of penile arteries, and the Vasilchenko questionnaire were implemented at the end of 4 months of placebo period and after 2 months of therapy with a study drug. Therapy with bisoprolol, carvedilol, and nebivolol was associated with significant elevation of parasympathetic part of vegetative nervous system tone, improvement of systolic blood flow in cavernous and dorsal arteries. Analysis of data obtained by Vasilchenko questionnaire demonstrated improvement of psychic and erectile components of sexual function. Thus bisoprolol, carvedilol, and nebivolol did not worsen sexual function of men with AH, improved spectral parameters of HRV and vascular blood flow in arteries of cavernous bodies.

  10. Characterizing the Input-Output Function of the Olfactory-Limbic Pathway in the Guinea Pig

    Directory of Open Access Journals (Sweden)

    Gian Luca Breschi

    2015-01-01

    Full Text Available Nowadays the neuroscientific community is taking more and more advantage of the continuous interaction between engineers and computational neuroscientists in order to develop neuroprostheses aimed at replacing damaged brain areas with artificial devices. To this end, a technological effort is required to develop neural network models which can be fed with the recorded electrophysiological patterns to yield the correct brain stimulation to recover the desired functions. In this paper we present a machine learning approach to derive the input-output function of the olfactory-limbic pathway in the in vitro whole brain of guinea pig, less complex and more controllable than an in vivo system. We first experimentally characterized the neuronal pathway by delivering different sets of electrical stimuli from the lateral olfactory tract (LOT and by recording the corresponding responses in the lateral entorhinal cortex (l-ERC. As a second step, we used information theory to evaluate how much information output features carry about the input. Finally we used the acquired data to learn the LOT-l-ERC “I/O function,” by means of the kernel regularized least squares method, able to predict l-ERC responses on the basis of LOT stimulation features. Our modeling approach can be further exploited for brain prostheses applications.

  11. Hybrid image and blood sampling input function for quantification of small animal dynamic PET data

    International Nuclear Information System (INIS)

    Shoghi, Kooresh I.; Welch, Michael J.

    2007-01-01

    We describe and validate a hybrid image and blood sampling (HIBS) method to derive the input function for quantification of microPET mice data. The HIBS algorithm derives the peak of the input function from the image, which is corrected for recovery, while the tail is derived from 5 to 6 optimally placed blood sampling points. A Bezier interpolation algorithm is used to link the rightmost image peak data point to the leftmost blood sampling point. To assess the performance of HIBS, 4 mice underwent 60-min microPET imaging sessions following a 0.40-0.50-mCi bolus administration of 18 FDG. In total, 21 blood samples (blood-sampled plasma time-activity curve, bsPTAC) were obtained throughout the imaging session to compare against the proposed HIBS method. MicroPET images were reconstructed using filtered back projection with a zoom of 2.75 on the heart. Volumetric regions of interest (ROIs) were composed by drawing circular ROIs 3 pixels in diameter on 3-4 transverse planes of the left ventricle. Performance was characterized by kinetic simulations in terms of bias in parameter estimates when bsPTAC and HIBS are used as input functions. The peak of the bsPTAC curve was distorted in comparison to the HIBS-derived curve due to temporal limitations and delay in blood sampling, which affected the rates of bidirectional exchange between plasma and tissue. The results highlight limitations in using bsPTAC. The HIBS method, however, yields consistent results, and thus, is a substitute for bsPTAC

  12. AN ACCURATE MODELING OF DELAY AND SLEW METRICS FOR ON-CHIP VLSI RC INTERCONNECTS FOR RAMP INPUTS USING BURR’S DISTRIBUTION FUNCTION

    Directory of Open Access Journals (Sweden)

    Rajib Kar

    2010-09-01

    Full Text Available This work presents an accurate and efficient model to compute the delay and slew metric of on-chip interconnect of high speed CMOS circuits foe ramp input. Our metric assumption is based on the Burr’s Distribution function. The Burr’s distribution is used to characterize the normalized homogeneous portion of the step response. We used the PERI (Probability distribution function Extension for Ramp Inputs technique that extends delay metrics and slew metric for step inputs to the more general and realistic non-step inputs. The accuracy of our models is justified with the results compared with that of SPICE simulations.

  13. Comparison of systemic right ventricular function in transposition of the great arteries after atrial switch and congenitally corrected transposition of the great arteries.

    Science.gov (United States)

    Morcos, Michael; Kilner, Philip J; Sahn, David J; Litt, Harold I; Valsangiacomo-Buechel, Emanuela R; Sheehan, Florence H

    2017-12-01

    In patients with transposition of the great arteries corrected by interatrial baffle (TGA) and those with congenitally corrected transposition of the great arteries (ccTGA) the right ventricle (RV) is subjected to systemic pressure and fails prematurely. Previous studies have demonstrated RV dysfunction may be more pronounced in patients with TGA. The present study sought to compare patients with TGA and ccTGA using three-dimensional (3D) techniques to comprehensively analyze the shape, volume, global and regional function in the systemic RV. We compared RV size, shape, and regional and global function in 25 patients with TGA, 17 patients with ccTGA, and 9 normal subjects. The RVs were reconstructed from cardiac Magnetic Resonance Images for 3D analyses. Compared to normal, the RV in TGA and ccTGA was dilated, rounded, and reduced in function. Compared to each other, TGA and ccTGA patients had similar RV size and shape. Global RV function was lower in TGA than ccTGA when assessed from ejection fraction (EF) (30 ± 7 vs. 35 ± 7, p = 0.02) and from normalized tricuspid annular systolic plane excursion (TAPSE) (0.10 ± 0.04 vs. 0.18 ± 0.04, p < 0.01). Basilar RV function was poorer in the TGA patients when compared to ccTGA. The systemic RVs in both TGA and ccTGA are dilated, spherical, and poorly functioning. Compared to ccTGA, TGA RVs have reduced TAPSE and worse basilar hypokinesis.

  14. Effect of periodontal therapy on arterial structure and function among aboriginal australians: a randomized, controlled trial.

    Science.gov (United States)

    Kapellas, Kostas; Maple-Brown, Louise J; Jamieson, Lisa M; Do, Loc G; O'Dea, Kerin; Brown, Alex; Cai, Tommy Y; Anstey, Nicholas M; Sullivan, David R; Wang, Hao; Celermajer, David S; Slade, Gary D; Skilton, Michael R

    2014-10-01

    Observational studies and nonrandomized trials support an association between periodontal disease and atherosclerotic vascular disease. Both diseases occur frequently in Aboriginal Australians. We hypothesized that nonsurgical periodontal therapy would improve measures of arterial function and structure that are subclinical indicators of atherosclerotic vascular disease. This parallel-group, randomized, open label clinical trial enrolled 273 Aboriginal Australians aged ≥18 years with periodontitis. Intervention participants received full-mouth periodontal scaling during a single visit, whereas controls received no treatment. Prespecified primary end points measured 12-month change in carotid intima-media thickness, an indicator of arterial structure, and 3- and 12-month change in pulse wave velocity, an indicator of arterial function. ANCOVA used complete case data to evaluate treatment group differences. End points could be calculated for 169 participants with follow-up data at 3 months and 168 participants at 12 months. Intima-media thickness decreased significantly after 12 months in the intervention group (mean reduction=-0.023 [95% confidence interval {CI}, -0.038 to -0.008] mm) but not in the control group (mean increase=0.002 [95% CI, -0.017 to 0.022] mm). The difference in intima-media thickness change between treatment groups was statistically significant (-0.026 [95% CI, -0.048 to -0.003] mm; P=0.03). In contrast, there were no significant differences between treatment groups in pulse wave velocity at 3 months (mean difference, 0.06 [95% CI, -0.17 to 0.29] m/s; P=0.594) or 12 months (mean difference, 0.21 [95% CI, -0.01 to 0.43] m/s; P=0.062). Periodontal therapy reduced subclinical arterial thickness but not function in Aboriginal Australians with periodontal disease, suggesting periodontal disease and atherosclerosis are significantly associated. © 2014 American Heart Association, Inc.

  15. Superselective intra-arterial chemoradiotherapy for advanced head and neck cancers. Evaluation of preservation of organ function

    International Nuclear Information System (INIS)

    Akisada, Takeshi; Harada, Tamotsu; Imai, Shigeki; Gyoten, Masayuki; Hiraoka, Takashi

    2008-01-01

    The objective of this study was to evaluate preservation of organ function in the treatment of superselective intra-arterial chemoradiotherapy for advanced head and neck cancers. Among 96 patients receiving concomitant radiation and intra-arterial docetaxel, systemic cisplatin and 5-fluorouracil (FU) chemotherapy, we identified laryngeal preservation rate, studied tracheostomy cases and gastrostomy cases, and evaluated videofluoroscopic examination and videoendoscopy. Laryngeal preservation rate of hypopharyngeal cancer is very high at 96.2%, and that of laryngeal cancer is high at 71.4%. Videofluoroscopic examination revealed improved swallowing function in 2 of 12, no change in 3, slightly worse in 5, and worse in 2 patients. Following treatment, the incidence of aspiration increased to 4 patients. Videoendoscopy revealed residual vallecula in a few cases. Only 7 patients (7.3%) required a tracheostomy and 4 patients (4.2%) required a gastrostomy. Most of the patients are able to swallow after chemoradiation. Our new chemoradiation protocol is as good as other treatment modalities for maintaining organ preservation and function. (author)

  16. The new technique of using the epigastric arteries in renal transplantation with multiple renal arteries

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Amirzargar

    2013-01-01

    Full Text Available The most common anatomic variant seen in the donor kidneys for renal transplantation is multiple renal arteries (MRA, which can cause an increased risk of complications. We describe the long-term outcomes of 16 years of experience in 76 kidney transplantations with MRAs. In a new reconstruction technique, we remove arterial clamps after anastomosing the donor to the recipient′s main renal vessels, which cause backflow from accessory arteries to prevent thrombosis. By this technique, we reduce the ischemic times as well as the operating times. Both in live or cadaver donor kidneys, lower polar arteries were anastomosed to the inferior epigastric artery and upper polar arteries were anastomosed to the superior epigastric arteries. Injection of Papaverine and ablation of sympathic nerves of these arteries dilate and prevent them from post-operative spasm. Follow-up DTPA renal scan in all patients showed good perfusion and function of the transplanted kidney, except two cases of polar arterial thrombosis. Mean creatinine levels during at least two years of follow-up remained acceptable. Patient and graft survival were excellent. No cases of ATN, hypertension, rejection and urologic complications were found. In conclusion, this technique can be safely and successfully utilized for renal transplantation with kidneys having MRAs, and may be associated with a lower complication rate and better graft function compared with the existing techniques.

  17. Evaluation of coronary artery disease by functional imaging from equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    He Zuoxiang

    1992-01-01

    Functional imagings were performed in 10 normals, 9 subjects with Non coronary Artery disease (NCAD), 33 CAD patients with documented MI (CAD-WMI) and 20 without MI (CAD-NMI). The sensitivity of LVGEF, LVREF and phase analysis at rest for detecting CAD-WMI was 66.7%, 78.8%, 93.9% respectively. LVGEF, LVREF during exercise for assessing CAD-NMI had the sensitivity of 90%, 80%, respectively, while specificity 90%. Early LVEF decrease, > 10% LVEF decrease and abnormal response at > 7 sectors during exercise were observed in 2 patients with 3 vessel. In conclusion, functional imaging were very useful for detecting CAD and evaluating its extent

  18. [Obesity as pathology of adipocytes: number of cells, volume of arterial bloodstream,local pools of circulation in vivo, natriuretic peptides and arterial hypertension].

    Science.gov (United States)

    Titov, V N; Dmitriev, V A

    2015-03-01

    The non-specific systemic biological reaction of arterial pressure from the level of organism. vasomotor center and proximal section of arterial bloodstream is appealed to compensate disorders of metabolism and microcirculation in distal section of arteries. This phenomenon occurs in several cases. The primarily local disorders of metabolism at autocrine level, physiological (aphysiological) death of cells, "littering" of intercellular medium become the cause of disorder of microcirculation in paracrin cenosises and deteriorate realization of biological functions of homeostasis, trophology, endoecology and adaptation. The local compensation of affected perfusion in paracrin cenosises at the expense of function of peripheral peristaltic pumps, redistribution of local bloodflow in biological reaction of endothelium-depended vaso-dilation has no possibility to eliminate disorders in realization of biological functions. The systemic increase of arterial pressure under absence of specific symptoms of symptomatic arterial hypertension is a test to detect disorder of biological functions of homeostasis, trophology, biological function of endoecology and adaptation. Allforms of arterial hypertension develop by common algorithm independently from causes of disorders of blood flow, microcirculation in distal section of arteries. The non-specific systemic compensation ofdisorders of metabolism from level of organism, in proximal section of arterial bloodstream always is the same one and results in aphysiological alterations in organs-targets. To comprehend etiological characteristics of common pathogenesis of arterial hypertension is possible in case of application of such technically complicated and still unclear in differential diagnostic of deranged functions modes of metabolomics.

  19. Effect of PPARγ Inhibition during Pregnancy on Posterior Cerebral Artery Function and Structure

    Directory of Open Access Journals (Sweden)

    Siu-Lung eChan

    2010-08-01

    Full Text Available Peroxisome proliferator-activated receptor-γ (PPARγ, a ligand-activated transcription factor, has protective roles in the cerebral circulation, and, is highly activated during pregnancy. Thus, we hypothesized that PPARγ is involved in the adaptation of cerebral vasculature to pregnancy. Nonpregnant (NP and late-pregnant (LP rats were treated with a specific PPARγ inhibitor GW9662 (10 mg/kg/day, in food or vehicle for 10 days and vascular function and structural remodeling were determined in isolated and pressurized posterior cerebral arteries (PCA. Expression of PPARγ and angiotensin type 1 receptor (AT1R in cerebral (pial vessels was determined by real-time RT-PCR. PPARγ inhibition decreased blood pressure and increased blood glucose in NP rats, but not in LP rats. PPARγ inhibition reduced dilation to acetylcholine and sodium nitroprusside in PCA from NP (p<0.05 vs. LP-GW, but not LP rats. PPARγ inhibition tended to increase basal tone and myogenic activity in PCA from NP rats, but not LP rats. Structurally, PPARγ inhibition increased wall-thickness in PCA from both NP and LP rats (p<0.05, but increased distensibility only in PCA from NP rats. Pregnancy decreased expression of PPARγ and AT1R (p<0.05 in cerebral arteries that was not affected by GW9662 treatment. These results suggest that PPARγ inhibition had significant effects on the function and structure of PCA in the NP state, but appeared to have less influence during pregnancy. Down-regulation of PPARγ and AT1R in cerebral arteries may be responsible for the lack of effect of PPARγ in cerebral vasculature and may be part of the vascular adaptation to pregnancy.

  20. Arterial function parameters in patients with metabolic syndrome and severe hypertriglyceridemia.

    Science.gov (United States)

    Rinkūnienė, Egidija; Butkutė, Eglė; Puronaitė, Roma; Petrulionienė, Žaneta; Dženkevičiūtė, Vilma; Kasiulevičius, Vytautas; Laucevičius, Aleksandras

    Hypertriglyceridemia (hTG) is 1 of the dyslipidemia manifestations in patients with metabolic syndrome (MetS). However, for several decades, the role of hTG in cardiovascular risk was not well established. The aim of this study was to assess the parameters of the vascular structure and function in patients with MetS and different degree of hTG. Patients (aged 40-65 years) with MetS were divided into 3 groups by triglyceride (TG) levels according to National Cholesterol Education Program Adult Treatment Panel III Guidelines: severe hTG (TG ≥ 500 mg/dL), moderate hTG (TG 200-499 mg/dL), and a control (TG severe TG was observed in 9.6% (n = 100) of patients. Overall TG concentration was 231.17 ± 184.23 mg/dL; in severe hTG group, TG concentration was 795.36 ± 368.45 mg/dL, in moderate hTG group 285.20 ± 70.86 mg/dL, and 112.48 ± 24.80 mg/dL in control group. AIxHR75 and IMT were the lowest in the severe hTG group (P severe hTG have lower IMT and AIxHR75 and higher PWV and mean arterial pressure. Many factors could affect arterial parameters, and more research are needed to investigate arterial parameters and hTG connection. Copyright © 2017 National Lipid Association. Published by Elsevier Inc. All rights reserved.

  1. Estimation of Input Function from Dynamic PET Brain Data Using Bayesian Blind Source Separation

    Czech Academy of Sciences Publication Activity Database

    Tichý, Ondřej; Šmídl, Václav

    2015-01-01

    Roč. 12, č. 4 (2015), s. 1273-1287 ISSN 1820-0214 R&D Projects: GA ČR GA13-29225S Institutional support: RVO:67985556 Keywords : blind source separation * Variational Bayes method * dynamic PET * input function * deconvolution Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.623, year: 2015 http://library.utia.cas.cz/separaty/2015/AS/tichy-0450509.pdf

  2. Passive heat therapy improves endothelial function, arterial stiffness and blood pressure in sedentary humans.

    Science.gov (United States)

    Brunt, Vienna E; Howard, Matthew J; Francisco, Michael A; Ely, Brett R; Minson, Christopher T

    2016-09-15

    A recent 30 year prospective study showed that lifelong sauna use reduces cardiovascular-related and all-cause mortality; however, the specific cardiovascular adaptations that cause this chronic protection are currently unknown. We investigated the effects of 8 weeks of repeated hot water immersion ('heat therapy') on various biomarkers of cardiovascular health in young, sedentary humans. We showed that, relative to a sham group which participated in thermoneutral water immersion, heat therapy increased flow-mediated dilatation, reduced arterial stiffness, reduced mean arterial and diastolic blood pressure, and reduced carotid intima media thickness, with changes all on par or greater than what is typically observed in sedentary subjects with exercise training. Our results show for the first time that heat therapy has widespread and robust effects on vascular function, and as such, could be a viable treatment option for improving cardiovascular health in a variety of patient populations, particularly those with limited exercise tolerance and/or capabilities. The majority of cardiovascular diseases are characterized by disorders of the arteries, predominantly caused by endothelial dysfunction and arterial stiffening. Intermittent hot water immersion ('heat therapy') results in elevations in core temperature and changes in cardiovascular haemodynamics, such as cardiac output and vascular shear stress, that are similar to exercise, and thus may provide an alternative means of improving health which could be utilized by patients with low exercise tolerance and/or capabilities. We sought to comprehensively assess the effects of 8 weeks of heat therapy on biomarkers of vascular function in young, sedentary subjects. Twenty young, sedentary subjects were assigned to participate in 8 weeks (4-5 times per week) of heat therapy (n = 10; immersion in a 40.5°C bath sufficient to maintain rectal temperature ≥ 38.5°C for 60 min per session) or thermoneutral water

  3. Measurement of regional cerebral blood flow using one-point arterial blood sampling and microsphere model with 123I-IMP. Correction of one-point arterial sampling count by whole brain count ratio

    International Nuclear Information System (INIS)

    Makino, Kenichi; Masuda, Yasuhiko; Gotoh, Satoshi

    1998-01-01

    The experimental subjects were 189 patients with cerebrovascular disorders. 123 I-IMP, 222 MBq, was administered by intravenous infusion. Continuous arterial blood sampling was carried out for 5 minutes, and arterial blood was also sampled once at 5 minutes after 123 I-IMP administration. Then the whole blood count of the one-point arterial sampling was compared with the octanol-extracted count of the continuous arterial sampling. A positive correlation was found between the two values. The ratio of the continuous sampling octanol-extracted count (OC) to the one-point sampling whole blood count (TC5) was compared with the whole brain count ratio (5:29 ratio, Cn) using 1-minute planar SPECT images, centering on 5 and 29 minutes after 123 I-IMP administration. Correlation was found between the two values. The following relationship was shown from the correlation equation. OC/TC5=0.390969 x Cn-0.08924. Based on this correlation equation, we calculated the theoretical continuous arterial sampling octanol-extracted count (COC). COC=TC5 x (0.390969 x Cn-0.08924). There was good correlation between the value calculated with this equation and the actually measured value. The coefficient improved to r=0.94 from the r=0.87 obtained before using the 5:29 ratio for correction. For 23 of these 189 cases, another one-point arterial sampling was carried out at 6, 7, 8, 9 and 10 minutes after the administration of 123 I-IMP. The correlation coefficient was also improved for these other point samplings when this correction method using the 5:29 ratio was applied. It was concluded that it is possible to obtain highly accurate input functions, i.e., calculated continuous arterial sampling octanol-extracted counts, using one-point arterial sampling whole blood counts by performing correction using the 5:29 ratio. (K.H.)

  4. Effects of diabetes and gender on mechanical properties of the arterial system in rats: aortic impedance analysis.

    Science.gov (United States)

    Chang, Kuo-Chu; Hsu, Kwan-Lih; Tseng, Yung-Zu

    2003-01-01

    We determined the effects of diabetes and gender on the physical properties of the vasculature in streptozotocin (STZ)-treated rats based on the aortic input impedance analysis. Rats given STZ 65 mg/kg i.v. were compared with untreated age-matched controls. Pulsatile aortic pressure and flow signals were measured and were then subjected to Fourier transformation for the analysis of aortic input impedance. Wave transit time was determined using the impulse response function of the filtered aortic input impedance spectra. Male but not female diabetic rats exhibited an increase in cardiac output in the absence of any significant changes in arterial blood pressure, resulting in a decline in total peripheral resistance. However, in each gender group, diabetes contributed to an increase in wave reflection factor, from 0.47 +/- 0.04 to 0.84 +/- 0.03 in males and from 0.46 +/- 0.03 to 0.81 +/- 0.03 in females. Diabetic rats had reduced wave transit time, at 18.82 +/- 0.60 vs 21.34 +/- 0.51 msec in males and at 19.63 +/- 0.37 vs 22.74 +/- 0.57 msec in females. Changes in wave transit time and reflection factor indicate that diabetes can modify the timing and magnitude of the wave reflection in the rat arterial system. Meanwhile, diabetes produced a fall in aortic characteristic impedance from 0.023 +/- 0.002 to 0.009 +/- 0.001 mmHg/min/kg/ml in males and from 0.028 +/- 0.002 to 0.014 +/- 0.001 mmHg/min/kg/ml in females. With unaltered aortic pressure, both the diminished aortic characteristic impedance and wave transit time suggest that the muscle inactivation in diabetes may occur in aortas and large arteries and may cause a detriment to the aortic distensibility in rats with either sex. We conclude that only rats with male gender diabetes produce a detriment to the physical properties of the resistance arterioles. In spite of male or female gender, diabetes decreases the aortic distensibility and impairs the wave reflection phenomenon in the rat arterial system.

  5. Influence of pleural drain insertion in lung function of patients undergoing coronary artery bypass grafting.

    Science.gov (United States)

    Ozelami Vieira, Irinea Beatriz Carvalho; Vieira, Fabiano F; Abrão, João; Gastaldi, Ada Clarice

    2012-01-01

    Longitudinal, prospective, randomized, blinded Trial to assess the influence of pleural drain (non-toxic PVC) site of insertion on lung function and postoperative pain of patients undergoing coronary artery bypass grafting in the first three days post-surgery and immediately after chest tube removal. Thirty six patients scheduled for elective myocardial revascularization with cardiopulmonary bypass (CPB) were randomly allocated into two groups: SX group (subxiphoid) and IC group (intercostal drain). Spirometry, arterial blood gases, and pain tests were recorded. Thirty one patients were selected, 16 in SX group and 15 in IC group. Postoperative (PO) spirometric values were higher in SX than in IC group (ppleural drain location on breathing. PaO(2) on the second PO increased significantly in SX group compared with IC group (pDrain with insertion in the subxiphoid region causes less change in lung function and discomfort, allowing better recovery of respiratory parameters. Copyright © 2012 Elsevier Editora Ltda. All rights reserved.

  6. Comparison of plasma input and reference tissue models for analysing [(11)C]flumazenil studies

    NARCIS (Netherlands)

    Klumpers, Ursula M. H.; Veltman, Dick J.; Boellaard, Ronald; Comans, Emile F.; Zuketto, Cassandra; Yaqub, Maqsood; Mourik, Jurgen E. M.; Lubberink, Mark; Hoogendijk, Witte J. G.; Lammertsma, Adriaan A.

    2008-01-01

    A single-tissue compartment model with plasma input is the established method for analysing [(11)C]flumazenil ([(11)C]FMZ) studies. However, arterial cannulation and measurement of metabolites are time-consuming. Therefore, a reference tissue approach is appealing, but this approach has not been

  7. Application of the Polytron 1000 VR for functional diagnosis and interventional examination of arteries of the lower extremity: First clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Kueffer, G.; Ziegler, L.; Hahn, D.

    1989-01-01

    The article reports the clinical experience gained with the POLYTRON-1000 VR system which has been used for all functional diagnostic tasks for detection of compression syndrome of the popliteal artery, and for diagnostic preparation and execution of atherectomy of pelvic and leg arteries with the Simpson catheter.

  8. Comparative in vivo analysis of the role of the adventitia and the endothelium on arterial mechanical function: relevance for aortic counterpulsation.

    Science.gov (United States)

    Bia, Daniel; Zócalo, Yanina; Wray, Sandra; Cabrera-Fischer, Edmundo I

    2017-06-09

    The comparative effect of the intimal and adventitial layers on arterial biomechanics control, in basal and altered conditions, remains to be elucidated. This study aimed (1) to characterize the arterial conduit (CF) and buffering (distensibility) function of the iliac arteries in in vivo animals, in which the intimal and adventitial layers were removed; (2) to determine the effects of intra-aortic ballon pumping (IABP) on simultaneously de-adventitialized (DA) and de-endothelialized (DE) iliac arteries before and after induced heart failure. Pressure and diameter signals were measured in the iliac arteries of sheep (n = 7) in which the adventitial and intima layer were removed. Intra-aortic balloon pump (IABP) assistance was used in a control state and after heart failure induction. Both DE and DA determined significant changes in arterial diameter, distensibility and CF. Changes were higher after DA than after DE in terms of distensibility and CF (p<0.05). DA followed by DE (DA + DE) showed significant increases in arterial diameter and CF, accompanied by a decrease in distensibility (p<0.05) with respect to intact arteries. Heart failure induction caused significant hemodynamic changes without modifying the already impaired local biomechanical parameters. Nonsignificant improvements in the biomechanical parameters of DA + DE iliac arteries were observed during IABP before and after heart failure induction. Biomechanical changes caused by DA of iliac arteries were more important than those observed after DE. The DA + DE arteries showed significant differences with respect to intact arteries and with DA or DE arteries. IABP-related effects on arterial mechanics were absent in DA + DE arteries.

  9. Reproducibility of rest and exercise stress contrast-enhanced calf perfusion magnetic resonance imaging in peripheral arterial disease

    Directory of Open Access Journals (Sweden)

    Jiji Ronny S

    2013-01-01

    Full Text Available Abstract Background The purpose was to determine the reproducibility and utility of rest, exercise, and perfusion reserve (PR measures by contrast-enhanced (CE calf perfusion magnetic resonance imaging (MRI of the calf in normal subjects (NL and patients with peripheral arterial disease (PAD. Methods Eleven PAD patients with claudication (ankle-brachial index 0.67 ±0.14 and 16 age-matched NL underwent symptom-limited CE-MRI using a pedal ergometer. Tissue perfusion and arterial input were measured at rest and peak exercise after injection of 0.1 mM/kg of gadolinium-diethylnetriamine pentaacetic acid (Gd-DTPA. Tissue function (TF and arterial input function (AIF measurements were made from the slope of time-intensity curves in muscle and artery, respectively, and normalized to proton density signal to correct for coil inhomogeneity. Perfusion index (PI = TF/AIF. Perfusion reserve (PR = exercise TF/ rest TF. Intraclass correlation coefficient (ICC was calculated from 11 NL and 10 PAD with repeated MRI on a different day. Results Resting TF was low in NL and PAD (mean ± SD 0.25 ± 0.18 vs 0.35 ± 0.71, p = 0.59 but reproducible (ICC 0.76. Exercise TF was higher in NL than PAD (5.5 ± 3.2 vs. 3.4 ± 1.6, p = 0.04. Perfusion reserve was similar between groups and highly variable (28.6 ± 19.8 vs. 42.6 ± 41.0, p = 0.26. Exercise TF and PI were reproducible measures (ICC 0.63 and 0.60, respectively. Conclusion Although rest measures are reproducible, they are quite low, do not distinguish NL from PAD, and lead to variability in perfusion reserve measures. Exercise TF and PI are the most reproducible MRI perfusion measures in PAD for use in clinical trials.

  10. Cardiac magnetic resonance imaging-derived pulmonary artery distensibility index correlates with pulmonary artery stiffness and predicts functional capacity in patients with pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Kang, Ki-Woon; Chang, Hyuk-Jae; Kim, Young-Jin; Choi, Byoung-Wook; Yang, Woo-In; Shim, Chi-Young; Ha, Jongwon; Chung, Namsik; Lee, Hye-Sun

    2011-01-01

    Increased stiffness of the pulmonary vascular bed is known to increase mortality in patients with pulmonary arterial hypertension (PAH); and pulmonary artery (PA) stiffness is also thought to be associated with exercise capacity. The purpose of the present study was to investigate whether cardiac magnetic resonance imaging (CMRI)-derived PA distensibility index correlates with PA stiffness estimated on right heart catheterization (RHC) and predicts functional capacity (FC) in patients with PAH. Thirty-five consecutive PAH patients (23% male, mean age, 44±13 years; 69% idiopathic) underwent CMRI, RHC, and 6-min walk test (6MWT). PA distensibility indices were derived from cross-sectional area change (%) in the transverse view, perpendicular to the axis of the main PA, on CMRI [(maximum area-minimum area)/minimum area during cardiac cycle]. Among the PA stiffness indices, pulmonary vascular resistance (PVR) and PA capacitance were calculated using hemodynamic dataset from RHC. CMRI-derived PA distensibility was inversely correlated with PVR (R 2 =0.34, P 2 =0.35, P 2 =0.61, P<0.001). Furthermore, PA distensibility <20% predicted poor FC (<400 m in 6MWT) with a sensitivity of 82% and a specificity of 94%. Non-invasive CMRI-derived PA distensibility index correlates with PA stiffness and can predict FC in patients with PAH. (author)

  11. Pulmonary artery wave propagation and reservoir function in conscious man: impact of pulmonary vascular disease, respiration and dynamic stress tests.

    Science.gov (United States)

    Su, Junjing; Manisty, Charlotte; Simonsen, Ulf; Howard, Luke S; Parker, Kim H; Hughes, Alun D

    2017-10-15

    Wave travel plays an important role in cardiovascular physiology. However, many aspects of pulmonary arterial wave behaviour remain unclear. Wave intensity and reservoir-excess pressure analyses were applied in the pulmonary artery in subjects with and without pulmonary hypertension during spontaneous respiration and dynamic stress tests. Arterial wave energy decreased during expiration and Valsalva manoeuvre due to decreased ventricular preload. Wave energy also decreased during handgrip exercise due to increased heart rate. In pulmonary hypertension patients, the asymptotic pressure at which the microvascular flow ceases, the reservoir pressure related to arterial compliance and the excess pressure caused by waves increased. The reservoir and excess pressures decreased during Valsalva manoeuvre but remained unchanged during handgrip exercise. This study provides insights into the influence of pulmonary vascular disease, spontaneous respiration and dynamic stress tests on pulmonary artery wave propagation and reservoir function. Detailed haemodynamic analysis may provide novel insights into the pulmonary circulation. Therefore, wave intensity and reservoir-excess pressure analyses were applied in the pulmonary artery to characterize changes in wave propagation and reservoir function during spontaneous respiration and dynamic stress tests. Right heart catheterization was performed using a pressure and Doppler flow sensor tipped guidewire to obtain simultaneous pressure and flow velocity measurements in the pulmonary artery in control subjects and patients with pulmonary arterial hypertension (PAH) at rest. In controls, recordings were also obtained during Valsalva manoeuvre and handgrip exercise. The asymptotic pressure at which the flow through the microcirculation ceases, the reservoir pressure related to arterial compliance and the excess pressure caused by arterial waves increased in PAH patients compared to controls. The systolic and diastolic rate constants

  12. Relationship between occupational exposure to lead and local arterial stiffness and left ventricular diastolic function in individuals with arterial hypertension

    International Nuclear Information System (INIS)

    Poreba, Rafal; Gac, Pawel; Poreba, Malgorzata; Antonowicz-Juchniewicz, Jolanta; Andrzejak, Ryszard

    2011-01-01

    Relationship between occupational exposure to lead and frequency of complications in persons with arterial hypertension has been poorly investigated. This study aimed at evaluation of the relationship between occupational exposure to lead and manifestation of an increased local arterial stiffness and left ventricular diastolic dysfunction. The studies included 105 men (mean age: 44.47 ± 9.12 years) with arterial hypertension, treated with hypotensive drugs: group I - men occupationally exposed to lead (n = 53), and group II - men not exposed to lead (n = 52). In echocardiographic examination, the left ventricular diastolic dysfunction was diagnosed significantly more frequently in group I than in group II. In eTracking examination mean values of stiffness parameter (β), augmentation index (AI) and one-point pulse wave velocity (PWV-β) were significantly higher and mean values of arterial compliance (AC) were significantly lower in group I than in group II. The logistic regression showed that in the group of persons with arterial hypertension occupationally exposed to lead a more advanced age, higher blood lead concentration and higher mean values of augmentation index represent independent risk factors of left ventricular diastolic dysfunction. The multifactorial regression showed that amongst persons with arterial hypertension occupationally exposed to lead higher blood zinc protoporphyrin concentration, a more advanced age and higher value of body mass index (BMI) represent independent risk factors of an increased local arterial stiffness. In summary, we should note that in the group of persons with arterial hypertension occupationally exposed to lead the study has demonstrated a significantly more frequent manifestation of left ventricular diastolic dysfunction and an increase in local arterial stiffness. - Highlights: → Amongst persons with AH exposed to Pb higher ZnPP represent independent risk factor of increased local arterial stiffness. → Higher Pb

  13. Central Arterial Function Measured by Non-invasive Pulse Wave Analysis is Abnormal in Patients with Duchenne Muscular Dystrophy.

    Science.gov (United States)

    Ryan, Thomas D; Parent, John J; Gao, Zhiqian; Khoury, Philip R; Dupont, Elizabeth; Smith, Jennifer N; Wong, Brenda; Urbina, Elaine M; Jefferies, John L

    2017-08-01

    Duchenne muscular dystrophy (DMD) is an X-linked recessive disorder caused by mutation of dystrophin. Cardiovascular involvement includes dilated cardiomyopathy. Non-invasive assessment of vascular function has not been evaluated in DMD. We hypothesize arterial wave reflection is abnormal in patients with DMD. Pulse wave analysis was performed on DMD patients with a SphygmoCor SCOR-PVx System to determine central blood pressure and augmentation index (AIx) as an assessment of arterial wave reflection. Results were compared to a control group. A total of 43 patients with DMD were enrolled, and compared to 43 normal controls. Central systolic blood pressure was lower, while both AIx-75 (7.8 ± 9.6% vs. 2.1 ± 10.4%, p 0.01, DMD vs. normal) and AIx-not corrected (16.8 ± 10.1% vs. -3.6 ± 10.9, p wave reflection when compared to normal controls, which may represent increased arterial stiffness. Overall there appears to be no effect on ventricular systolic function, however the long-term consequence in this group is unknown. Further study is required to determine the mechanism of these differences, which may be related to the effects of systemic steroids or the role of dystrophin in vascular function.

  14. A content analysis of peripheral arterial disease patient-reported outcome measures using the International Classification of Functioning, Disability and Health.

    Science.gov (United States)

    Osborne, Candice Lee; Kauvar, David Seth

    2017-10-17

    The purpose of this study was to link, classify and describe the content of peripheral arterial disease (PAD)-specific patient-reported outcome measures using the International Classification of Functioning. The results were then analyzed to determine if these assessments provide clinicians and researchers with a comprehensive understanding of the lived experience of patients with PAD. Each meaningful concept in identified PAD assessments was linked to the International Classification of Functioning, Disability and Health to determine included and excluded content areas. An overall perspective was assigned to each assessment item. Inter-rater reliability was established using a kappa statistic. The body functions component is most frequently addressed overall followed by the activities and participation component. International Classification of Functioning chapter and category distribution vary greatly between assessments and no assessment comprehensively examines community participation and relationships. The majority of the assessment items are of the health status-disability and quality of life perspectives. The results of this study suggest the need for the development of a comprehensive PAD assessment that includes a more even distribution of International Classification of Functioning topics and subtopics. A more comprehensive assessment would better capture the lived experience of this patient population. Implications for Rehabilitation A better understanding of the data collected using the current peripheral arterial disease-specific patient-reported outcome measures may contribute to the development of more comprehensive assessment tools that will ultimately lead to improved patient care. This study contributes to the preliminary foundation for the development of a peripheral arterial disease International Classification of Functioning, Disability and Health Core Set. Clinicians and researchers interested in using peripheral arterial disease

  15. Four-dimensional echocardiography area strain combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis.

    Science.gov (United States)

    Deng, Yan; Peng, Long; Liu, Yuan-Yuan; Yin, Li-Xue; Li, Chun-Mei; Wang, Yi; Rao, Li

    2017-09-01

    The aim of this prospective study was to assess the diagnosis value of four-dimensional echocardiography area strain (AS) combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis. Based on treadmill exercise load status, two-dimensional conventional echocardiography and four-dimensional echocardiography area strain were performed on patients suspected coronary artery disease before coronary angiogram. Thirty patients (case group) with mild left anterior descending coronary artery stenosis (stenosis Four-dimensional echocardiography area strain combined with exercise stress echocardiography could sensitively find left ventricular regional systolic function abnormality in patients with mild single vessel coronary artery stenosis, and locate stenosis coronary artery accordingly. © 2017, Wiley Periodicals, Inc.

  16. [Clinical, functional and biochemical characteristics of arterial hypertension in military men under chronic stress].

    Science.gov (United States)

    Shpagina, L A; Ermakova, M A; Volkova, E A; Iakovleva, S A

    2008-01-01

    Peculiarities of military occupational activities are repeated stress and high degree of psychoemotional strain. The article deals with results of momentary study covering a select from military men cohort, with thyroid tests, renal functional tests, diurnal monitoring of blood pressure and psychologic state assessment. Course of arterial hypertension in military men subjected to chronic stress presents prevailing systolic-diastolic and diastolic variants with excessive decrease of blood pressure at night, with high values of albuminuria. Psychologic state of the military men examined, whe were subjects to chronic stress, was mostly mixed reactivity type with general overstrain and somatization of inner conflict (psychosomatic variant of dysadaptation). The authors demonstrated close correlation between intrinsic emotional strain degree with arterial hypertension type according to "hyper-dipper" variant and free T3 level.

  17. The Renal Arterial Resistance Index Predicts Worsening Renal Function in Chronic Heart Failure Patients

    Science.gov (United States)

    Iacoviello, Massimo; Monitillo, Francesco; Leone, Marta; Citarelli, Gaetano; Doronzo, Annalisa; Antoncecchi, Valeria; Puzzovivo, Agata; Rizzo, Caterina; Lattarulo, Maria Silvia; Massari, Francesco; Caldarola, Pasquale; Ciccone, Marco Matteo

    2016-01-01

    Background/Aim The renal arterial resistance index (RRI) is a Doppler measure, which reflects abnormalities in the renal blood flow. The aim of this study was to verify the value of RRI as a predictor of worsening renal function (WRF) in a group of chronic heart failure (CHF) outpatients. Methods We enrolled 266 patients in stable clinical conditions and on conventional therapy. Peak systolic velocity and end diastolic velocity of a segmental renal artery were obtained by pulsed Doppler flow, and RRI was calculated. Creatinine serum levels were evaluated at baseline and at 1 year, and the changes were used to assess WRF occurrence. Results During follow-up, 34 (13%) patients showed WRF. RRI was associated with WRF at univariate (OR: 1.13; 95% CI: 1.07–1.20) as well as at a forward stepwise multivariate logistic regression analysis (OR: 1.09; 95% CI: 1.03–1.16; p = 0.005) including the other univariate predictors. Conclusions Quantification of arterial renal perfusion provides a new parameter that independently predicts the WRF in CHF outpatients. Its possible role in current clinical practice to better define the risk of cardiorenal syndrome progression is strengthened. PMID:27994601

  18. Inverse parameter identification for a branching 1 D arterial network

    CSIR Research Space (South Africa)

    Bogaers, Alfred EJ

    2012-07-01

    Full Text Available In this paper we investigate the invertability of a branching 1 D arterial blood flow network. We limit our investigation to a single bifurcating vessel, where the material properties, unloaded areas and variables characterizing the input and output...

  19. Subarachnoid hemorrhage enhances endothelin receptor expression and function in rat cerebral arteries

    DEFF Research Database (Denmark)

    Hansen-Schwartz, Jacob; Hoel, Natalie Løvland; Zhou, Mingfang

    2003-01-01

    OBJECTIVE: Inspired by organ culture-induced changes in the vascular endothelin (ET) receptor population, we investigated whether such changes occur in cerebral arteries in a rat subarachnoid hemorrhage (SAH) model. METHODS: SAH was induced with injection of 250 microl of blood into the prechiasm......OBJECTIVE: Inspired by organ culture-induced changes in the vascular endothelin (ET) receptor population, we investigated whether such changes occur in cerebral arteries in a rat subarachnoid hemorrhage (SAH) model. METHODS: SAH was induced with injection of 250 microl of blood...... into the prechiasmatic cistern. After 2 days, the middle cerebral artery, basilar artery, and posterior communicating artery were harvested. Pharmacological studies were performed in vitro, and levels of messenger ribonucleic acid (mRNA) were quantified in real-time reverse transcriptase-polymerase chain reaction assays....... RESULTS: In the middle cerebral artery and basilar artery from rats with induced SAH, enhanced biphasic responses to ET-1 were observed. The -log(50% effective concentration) value for the high-affinity phase was approximately 12, compared with approximately 8.5 for sham-operated animals...

  20. Mean pressure of pulmonary arteries in non-callous silicosis at states 1 to 2 as determined by radiology in comparison to parameters of pulmonary function

    Energy Technology Data Exchange (ETDEWEB)

    Jakob, M; Konrad, A; Adam, P; Scharf, R

    1984-11-19

    Fifty coal miners suffering from reticulonodular silicosis underwent catheterization of the right heart and showed latent or manifest pulmonary hypertension. It has been found that the statistical relationship between pulmonary arterial pressure and pulmonary function was only a loose one. Thirty percent of the studied subjects presented no alterations of the lung function but an increased pulmonary artery mean pressure at rest and under exercise, indicating that the Euler-Liljestrand-mechanism could hardly be responsible for these pressure changes. Subjects with silicosis who presented impaired lung function showed statistically significant higher pulmonary artery pressures than those without alteration of the lung function. It is likely that an additional pressure increase occurs secondary to Euler-Liljestrand-mechanism, when restrictive or obstructive impairments of ventilation emerge from the pneumoconiosis.

  1. Lessons learned using HAMMLAB experimenter systems: Input for HAMMLAB 2000 functional requirements

    International Nuclear Information System (INIS)

    Sebok, Angelia L.

    1998-02-01

    To design a usable HAMMLAB 2000, lessons learned from use of the existing HAMMLAB must be documented. User suggestions are important and must be taken into account. Different roles in HAMMLAB experimental sessions are identified, and major functions of each role were specified. A series of questionnaires were developed and administered to different users of HAMMLAB, each tailored to the individual job description. The results of those questionnaires are included in this report. Previous HAMMLAB modification recommendations were also reviewed, to provide input to this document. A trial experimental session was also conducted, to give an overview of the tasks in HAMMLAB. (author)

  2. Protective effects of simvastatin on coronary artery function in swine with acute infection

    DEFF Research Database (Denmark)

    Liuba, Petru; Pesonen, Erkki; Forslid, Anders

    2006-01-01

    cholesterol) between the groups (p>0.2). CONCLUSION:: Acute infection is associated with impairment of the muscarinic and kinin-related reactivity of coronary circulation. These functional abnormalities are in part prevented by simvastatin through mechanisms unrelated to lipid lowering......BACKGROUND:: The risk for coronary events may rise during acute infection. Perturbation in coronary endothelial function emerges as one important link. We investigated whether simvastatin could protect the coronary arterial function from the adverse effects of acute infection in swine. METHODS......:: Coronary endothelium-dependent and -independent vasomotor responses were assessed by Doppler velocimetry in 12 Chlamydia pneumoniae-infected and 6 sham-infected swine 2 weeks after intratracheal inoculation. Half of animals from the infection group were pre-treated with simvastatin (80mg daily), while...

  3. Quantitative determination of arterial wall mechanics with pulse oximetric finger plethysmography.

    Science.gov (United States)

    Kato, R; Sato, J; Iuchi, T; Higuchi, Y

    1999-10-30

    The plethysmographic wave of pulse oximetry reflects arterial pulsation at the fingertip. Since arterial pressure and the pulsatile component of the arterial cross section represent the input and output of the fingertip arterial system, respectively, arterial wall mechanics may be delineated from their relationship. We aimed to construct a mathematical model of the fingertip arterial wall from the relationship between the plethysmographic wave and arterial pressure. The pulse oximetric plethysmographic signal at the forefinger and pressure at the ipsilateral radial artery were measured. Employing the data, simple mathematical models with one to four mechanical elements were tested in terms of the goodness of fit and the physiological implications. The determined model was applied to the data obtained during administration of vasoactive agents in anesthetized patients. The mathematical model suited for describing arterial wall mechanics was a four-element, two-compartment model. The two compartments represent passive mechanical and active contractile properties, respectively. In the application of the model to the anesthetized patients, the vasoactive agents produced changes in the model parameters that implied mechanical alterations in the arterial wall. These findings suggest the benefit of the four-element, two-compartment model in analyzing peripheral vascular wall mechanics influenced by various stimuli in intensive care and anesthesia.

  4. Arterial Injury and Endothelial Repair: Rapid Recovery of Function after Mechanical Injury in Healthy Volunteers

    Directory of Open Access Journals (Sweden)

    Lindsey Tilling

    2014-01-01

    Full Text Available Objective. Previous studies suggest a protracted course of recovery after mechanical endothelial injury; confounders may include degree of injury and concomitant endothelial dysfunction. We sought to define the time course of endothelial function recovery using flow-mediated dilation (FMD, after ischaemia-reperfusion (IR and mechanical injury in patients and healthy volunteers. The contribution of circulating CD133+/CD34+/VEGFR2+ “endothelial progenitor” (EPC or repair cells to endothelial repair was also examined. Methods. 28 healthy volunteers aged 18–35 years underwent transient forearm ischaemia induced by cuff inflation around the proximal biceps and radial artery mechanical injury induced by inserting a wire through a cannula. A more severe mechanical injury was induced using an arterial sheath and catheter inserted into the radial artery of 18 patients undergoing angiography. Results. IR and mechanical injury produced immediate impairment of FMD (from 6.5 ± 1.2% to 2.9 ± 2.2% and from 7.4 ± 2.3% to 1.5 ± 1.6% for IR and injury, resp., each P<0.001 but recovered within 6 hours and 2 days, respectively. FMD took up to 4 months to recover in patients. Circulating EPC did not change significantly during the injury/recovery period in all subjects. Conclusions. Recovery of endothelial function after IR and mechanical injury is rapid and not associated with a change in circulating EPC.

  5. Impaired Arterial Smooth Muscle Cell Vasodilatory Function In Methamphetamine Users

    Directory of Open Access Journals (Sweden)

    Ghaemeh Nabaei

    2017-02-01

    Full Text Available Objectives: Methamphetamine use is a strong risk factor for stroke. This study was designed to evaluate arterial function and structure in methamphetamine users ultrasonographically. Methods: In a cross-sectional study, 20 methamphetamine users and 21 controls, aged between 20 and 40years, were enrolled. Common carotid artery intima-media thickness (CCA-IMT marker of early atherogenesis, flow-mediated dilatation (FMD determinants of endothelium-dependent vasodilation, and nitroglycerine-mediated dilatation (NMD independent marker of vasodilation were measured in two groups. Results: There were no significant differences between the two groups regarding demographic and metabolic characteristics. The mean (±SD CCA-IMT in methamphetamine users was 0.58±0.09mm, versus 0.59±0.07mm in the controls (p=0.84. Likewise, FMD% was not significantly different between the two groups [7.6±6.1% in methamphetamine users vs. 8.2±5.1% in the controls; p=0.72], nor were peak flow and shear rate after hyperemia. However, NMD% was considerably decreased in the methamphetamine users [8.5±7.8% in methamphetamine users vs. 13.4±6.2% in controls; p=0.03]. Conclusion: According to our results, NMD is reduced among otherwise healthy methamphetamine users, which represents smooth muscle dysfunction in this group. This may contribute to the high risk of stroke among methamphetamine users.

  6. A comparison of long-term functional outcome after 2 middle cerebral artery occlusion models in rats.

    Science.gov (United States)

    Roof, R L; Schielke, G P; Ren, X; Hall, E D

    2001-11-01

    Proven behavioral assessment strategies for testing potential therapeutic agents in rat stroke models are needed. Few studies include tasks that demand higher levels of sensorimotor and cognitive function. Because behavioral outcome and rate of recovery vary among ischemia models, there is a need to characterize and compare performance on specific tasks across models. To this end, sensorimotor and cognitive deficits were assessed during a 5-week period after either permanent proximal middle cerebral artery occlusion (pMCAO) or permanent distal middle cerebral artery occlusion combined with a 90-minute occlusion of both common carotid arteries (dMCAO/tCCAO) in Sprague-Dawley rats. The EBST, hindlimb and forelimb placing, and cylinder tests were given at regular intervals postinjury to assess sensorimotor function. Cognitive function was assessed with a multitrial water navigation task. pMCAO, which caused both striatal and cortical damage, produced persistent sensorimotor and cognitive deficits. Limb placing responses and postural reflexes were impaired throughout the month of testing. A persistent bias for using the ipsilateral forelimb for wall movements in the cylinder test was observed as well as a bias for landing on the opposite forelimb. pMCAO rats were also impaired in the water navigation task. dMCAO/tCCAO, which caused only cortical damage, produced similar sensorimotor deficits, but these were greatly diminished by 2 weeks after injury. No impairment was found for water tank navigation. Correlations between forelimb placing (both models), water navigation performance (pMCAO model), and sensorimotor asymmetry (dMCAOtCCAO model) and infarct volume were observed. Based on the range of functions affected and stability of observed deficits, the pMCAO model appears to be preferable to the dMCAO/tCCAO model for use in assessing therapeutic agents for stroke.

  7. Arterial stiffness

    Directory of Open Access Journals (Sweden)

    Ursula Quinn

    2012-09-01

    Full Text Available Measurements of biomechanical properties of arteries have become an important surrogate outcome used in epidemiological and interventional cardiovascular research. Structural and functional differences of vessels in the arterial tree result in a dampening of pulsatility and smoothing of blood flow as it progresses to capillary level. A loss of arterial elastic properties results a range of linked pathophysiological changes within the circulation including increased pulse pressure, left ventricular hypertrophy, subendocardial ischaemia, vessel endothelial dysfunction and cardiac fibrosis. With increased arterial stiffness, the microvasculature of brain and kidneys are exposed to wider pressure fluctuations and may lead to increased risk of stroke and renal failure. Stiffening of the aorta, as measured by the gold-standard technique of aortic Pulse Wave Velocity (aPWV, is independently associated with adverse cardiovascular outcomes across many different patient groups and in the general population. Therefore, use of aPWV has been proposed for early detection of vascular damage and individual cardiovascular risk evaluation and it seems certain that measurement of arterial stiffness will become increasingly important in future clinical care. In this review we will consider some of the pathophysiological processes that result from arterial stiffening, how it is measured and factors that may drive it as well as potential avenues for therapy. In the face of an ageing population where mortality from atheromatous cardiovascular disease is falling, pathology associated with arterial stiffening will assume ever greater importance. Therefore, understanding these concepts for all clinicians involved in care of patients with cardiovascular disease will become vital.

  8. Changes in endothelial function, arterial stiffness and blood pressure in pregnant women after consumption of high-flavanol and high-theobromine chocolate: a double blind randomized clinical trial.

    Science.gov (United States)

    Babar, Asma; Bujold, Emmanuel; Leblanc, Vicky; Lavoie-Lebel, Élise; Paquette, Joalee; Bazinet, Laurent; Lemieux, Simone; Marc, Isabelle; Abdous, Belkacem; Dodin, Sylvie

    2018-04-16

    The aim of this 2-group, parallel, double blind single-centre RCT was to evaluate the acute and chronic impacts of high flavanol high theobromine (HFHT) chocolate consumption on endothelial function, arterial stiffness and blood pressure (BP) in women at risk of preeclampsia. 131 pregnant women considered at risk of preeclampsia based on uterine artery Doppler ultrasound were divided into two groups (HFHT or low flavanol and theobromine chocolate (LFLT). Acute changes in plasma flavanol and theobromine, peripheral arterial tonometry and BP were evaluated at randomization (0, 60 and 120 min after a single 40-g dose of chocolate) and again 6 and 12 weeks after daily 30-g chocolate intake. The EndoPAT 2000 provided reactive hyperemia index (RHI) and adjusted augmentation index (AIx) as markers for endothelial function and arterial stiffness, respectively. Compared with LFLT, acute HFHT intake significantly increased plasma epicatechin and theobromine (p theobromine (p theobromine concentrations and decreased arterial stiffness, with no effect on endothelial function and a marginal increase in diastolic BP. Chronic HFHT intake increased plasma theobromine, though it did not have positive impacts on endothelial function, arterial stiffness or BP when compared to LFLT in pregnant women at risk of PE.

  9. Influence of orlistat therapy on serum insulin level and morphological and functional parameters of peripheral arterial circulation in obese patients

    Directory of Open Access Journals (Sweden)

    Hajduković Zoran

    2005-01-01

    Full Text Available Background/Aim. Insulin resistance is related to accelerated atherosclerosis, whereas weight loss is associated with the increasing insulin sensitivity, the improvement of functional and the morphological parameters of arterial circulation, and the reduction of cardiovascular morbidity and mortality. The aim of our study was to evaluate the influence of orlistat treatment on serum insulin level and functional and morphologic parameters of peripheral arterial circulation. Methods. We conducted a prospective, randomized, double − blind, placebo − controlled study. Thirty patients with body mass index over 30 kg/m2 normotensive, nonsmokers, without clinically manifested cardiovascular disease or diabetes were randomly assigned either orlistat (120 mg, 3 times daily; n = 20 or placebo (n = 10 in a double − blind manner. All of the patients were on individually calculated hypocaloric diet. The follow-up period was 24 weeks. Arterial pressure, fasting serum glucose and insulin level, triglycerides, total cholesterol and low density lipoprotein-cholesterol were determined at the beginning, following 3 and 6 months. Also, the intima − media thickness of right superficial femoral artery and the mean blood flow velocity were determined with ultrasonography. Results. Inside the period of 3 and 6 months, there were the greater reductions of body mass index, arterial pressure, fasting glucose and insulin level, total cholesterol, low density lipoproteins, as well as the greater reductions of mean velocity blood flow and peripheral pulse pressure in the orlistat group vs the placebo group (p < 0.01. Greater reductions in the waist circumference and intima − media thickness were registered following 6 months in the orlistat vs the placebo group (p < 0.01. Conclusion. In the group of obese patients orlistat therapy reduced risk factors, serum insulin level and improved early arterial functional changes as assessed with the reductions of the mean

  10. Relationship of cerebral arterial stenosis to cognitive and memory disorders

    Institute of Scientific and Technical Information of China (English)

    Jifeng Li; Zhou Wang; Shenggang Sun; Gaomei Cai; Kejin Gu; Yaoqun Li

    2006-01-01

    BACKGROUND: Cerebral arterial stenosis can cause cerebral hypoperfusion, and than result in the decline of cognitive function, whereas the cognitive dysfunction induced by different cerebral arterial stenosis have different manifestations and types.OBJECTIVE: To observe the differences of cognitive and memory dysfunctions in patients with cerebral arterial stenosis of different types.DESIGN: A comparative observation.SETTING: Affiliated Hospital of Jining Medical College.PARTICIPANTS: Forty-two outpatients or inpatients with cerebral arterial stenosis were selected from the Department of Neurology, Affiliated Hospital of Jining Medical College from February 2005 to January 2006,including 25 males and 17 females. There were 18 cases of internal carotid arterial stenosis, 14 cases of vertebrobasilar arterial stenosis and 10 cases of whole cerebral arterial stenosis. The diagnostic standards for cerebral arterial stenosis were identified according to North American Symptomatic Carotid Endarterectomy Trial (NAS CET). Meanwhile, 18 healthy physical examinees were enrolled as the control group, including 10males and 8 females, aged 58-80 years old. All the enrolled subjects were informed and agreed with the detection and evaluation.METHODS: ① The memory function was evaluated using revised Wechsler memory scale for adults, including long-term memory (experience, orientation and counting), short-term memory (visual recognition, picture memory, visual regeneration, association and thigmesthesia) and sensory memory (forward and backward recitation of numbers). The scale scores were turned to memory quotients. The higher the scores, the better the memory function. ② The cognitive function was evaluated using revised Wechsler adult intelligence scale:It consisted of eleven subtests, including six language scales (information, digit span, vocabulary, arithmetics,apprehension, similarity) and five operation scales (picture completion, picture arrangement, block design

  11. Evaluation of functional severity of coronary artery disease and fluid dynamics' influence on hemodynamic parameters: A review.

    Science.gov (United States)

    Govindaraju, Kalimuthu; Badruddin, Irfan Anjum; Viswanathan, Girish N; Ramesh, S V; Badarudin, A

    2013-05-01

    Coronary Artery Disease (CAD) is responsible for most of the deaths in patients with cardiovascular diseases. Diagnostic coronary angiography analysis offers an anatomical knowledge of the severity of the stenosis. The functional or physiological significance is more valuable than the anatomical significance of CAD. Clinicians assess the functional severity of the stenosis by resorting to an invasive measurement of the pressure drop and flow. Hemodynamic parameters, such as pressure wire assessment fractional flow reserve (FFR) or Doppler wire assessment coronary flow reserve (CFR) are well-proven techniques to evaluate the physiological significance of the coronary artery stenosis in the cardiac catheterization laboratory. Between the two techniques mentioned above, the FFR is seen as a very useful index. The presence of guide wire reduces the coronary flow which causes the underestimation of pressure drop across the stenosis which leads to dilemma for the clinicians in the assessment of moderate stenosis. In such condition, the fundamental fluid mechanics is useful in the development of new functional severity parameters such as pressure drop coefficient and lesion flow coefficient. Since the flow takes place in a narrowed artery, the blood behaves as a non-Newtonian fluid. Computational fluid dynamics (CFD) allows a complete coronary flow simulation to study the relationship between the pressure and flow. This paper aims at explaining (i) diagnostic modalities for the evaluation of the CAD and valuable insights regarding FFR in the evaluation of the functional severity of the CAD (ii) the role of fluid dynamics in measuring the severity of CAD. Copyright © 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. Late Posthemorrhagic Structural and Functional Changes in Pulmonary Circulation Arteries

    Directory of Open Access Journals (Sweden)

    S. A. Andreyeva

    2008-01-01

    Full Text Available Objective: to reveal the major regularities and mechanisms of morphological changes in the rat pulmonary circulation arteries in the late posthemorrhagic period and to compare them with age-related features of the vessels. Materials and methods: experiments to generate graduated hemorrhagic hypotension with the blood pressure being maintained at 40 mm Hg were carried out on young (5—6-month albino male Wistar rats. Throughout hypotension and 60 days after blood loss, the blood was tested to determine low and average molecular-weight substances by spectrophotometry and the pro- and antioxidative systems by chemiluminescence. Pulmonary circulation arteries were morphologically studied in young animals, rats in the late posthemorrhagic period and old (24—25-month rats. Results. Sixty-minute hemorrhagic hypotension leads to the development of endotoxemia and imbalance of the pro- and antioxidative systems, the signs of which are observed in the late periods (2 months after hypotension. At the same time, the posthemorrhagic period is marked by the significant pulmonary circulation arterial morphological changes comparable with their age-related alterations in old rat. This shows up mainly in the reorganization of a connective tissue component in the vascular wall: the elevated levels of individual collagen fibers, their structural changes, elastic medial membrane destruction and deformity. At the same time, there is a change in the morphometric parameters of vessels at all study stages while their lowered flow capacity is only characteristic for intraorgan arteries. Conclusion: The increased activity of free radical oxidation and endotoxemia may be believed to be one of the causes of morphological changes in pulmonary circulation arteries in the late posthemorrhagic period, which is similar to age-related vascular alterations. Key words: hemorrhagic hypotension, pulmonary circulation arteries, free radical oxidation, endotoxemia, remodeling, late

  13. Characterizing Resting-State Brain Function Using Arterial Spin Labeling

    Science.gov (United States)

    Jann, Kay; Wang, Danny J.J.

    2015-01-01

    Abstract Arterial spin labeling (ASL) is an increasingly established magnetic resonance imaging (MRI) technique that is finding broader applications in studying the healthy and diseased brain. This review addresses the use of ASL to assess brain function in the resting state. Following a brief technical description, we discuss the use of ASL in the following main categories: (1) resting-state functional connectivity (FC) measurement: the use of ASL-based cerebral blood flow (CBF) measurements as an alternative to the blood oxygen level-dependent (BOLD) technique to assess resting-state FC; (2) the link between network CBF and FC measurements: the use of network CBF as a surrogate of the metabolic activity within corresponding networks; and (3) the study of resting-state dynamic CBF-BOLD coupling and cerebral metabolism: the use of dynamic CBF information obtained using ASL to assess dynamic CBF-BOLD coupling and oxidative metabolism in the resting state. In addition, we summarize some future challenges and interesting research directions for ASL, including slice-accelerated (multiband) imaging as well as the effects of motion and other physiological confounds on perfusion-based FC measurement. In summary, this work reviews the state-of-the-art of ASL and establishes it as an increasingly viable MRI technique with high translational value in studying resting-state brain function. PMID:26106930

  14. Structural and Functional Coronary Artery Abnormalities in Patients With Vasospastic Angina Pectoris

    DEFF Research Database (Denmark)

    Ong, Peter; Aziz, Ahmed; Hansen, Henrik Steen

    2015-01-01

    Coronary spasm is involved in many clinical scenarios, such as stable angina, acute coronary syndrome, sudden cardiac death, non-ischemic cardiomyopathy, arrhythmia and syncope. In recent years, imaging tools such as computerized tomographic angiography, intravascular ultrasound or optical...... coherence tomography have been applied to study the coronary pathology in patients with vasospastic angina. Patients with vasospastic angina represent a heterogeneous cohort of patients with regard to the extent of concomitant coronary atherosclerosis. They share the common pathophysiological phenomenon...... of this article is to review structural and functional coronary artery abnormalities in patients with vasospastic angina....

  15. Impaired cerebrovascular function in coronary artery disease patients and recovery following cardiac rehabilitation.

    Directory of Open Access Journals (Sweden)

    Udunna C Anazodo

    2016-01-01

    Full Text Available Coronary artery disease (CAD poses a risk to the cerebrovascular function of older adults and has been linked to impaired cognitive abilities. Using magnetic resonance perfusion imaging, we investigated changes in resting cerebral blood flow (CBF and cerebrovascular reactivity (CVR to hypercapnia in 34 coronary artery disease (CAD patients and 21 age-matched controls. Gray matter volume images were acquired and used as a confounding variable to separate changes in structure from function. Compared to healthy controls, CAD patients demonstrated reduced CBF in the superior frontal, anterior cingulate, insular, pre- and post-central gyri, middle temporal and superior temporal regions. Subsequent analysis of these regions demonstrated decreased CVR in the anterior cingulate, insula, postcentral and superior frontal regions. Except in the superior frontal and precentral regions, regional reductions in CBF and CVR were identified in brain areas where no detectable reductions in gray matter volume were observed, demonstrating that these vascular changes were independent of brain atrophy. Because aerobic fitness training can improve brain function, potential changes in regional CBF were investigated in the CAD patients after completion of a 6-month exercise-based cardiac rehabilitation program. Increased CBF was observed in the bilateral anterior cingulate, as well as recovery of CBF in the dorsal aspect of the right anterior cingulate, where the magnitude of increased CBF was roughly equal to the reduction in CBF at baseline compared to controls. These exercise-related improvements in CBF in the anterior cingulate is intriguing given the role of this area in cognitive processing and regulation of cardiovascular autonomic control.

  16. [Ultrastructure of the intima of human pial arteries in arterial hypertension].

    Science.gov (United States)

    Chertok, V M; Kotsiuba, A E; Babich, E V

    2009-01-01

    Ultrastructure of the intima of human pial arteries obtained from 5 male cadavers of practically healthy individuals and from 8 cadavers of the patients with the intravitally diagnosed grade I arterial hypertension (AH) was studied by scanning and transmission electron microscopy. AH was found to be associated with the remodeling of the intimal structural elements in the pial arteries. In most arteries, the changes were detected in the microrelief of the luminal surface and in the permeability of the vascular endothelial lining and of the subendothelial layer. During this remodeling, some endothelial cells were found in the state of structural and functional adaptation to the elevated arterial pressure, while the others were undergoing the dystrophic changes. The latter include the cells containing lipid inclusions, as well as the endothelial cells presumably in the state of apoptosis. The destruction of the intercellular junctions, the disturbances in the endothelium permeability contributed to the development of subendothelial layer edema, resulting in its significant thickening. This layer became looser and contained abundant collagen fibrils.

  17. Functional assessment of the hepatic arterial blood flow by pharmacoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Stellamor, K; Hruby, W; Peschl, L

    1981-12-01

    By means of celiacography it was possible to demonstrate that parenteral medication with parathormone creates a selective dilatation of the liver vessels in man, provided that they are dilatable. This hemodynamic hormone effect could not be traced in the other mesenteric vessels. The increase of portal hypertension resulting from cirrhosis leads to a loss of the dilating ability of liver vessels. This regressive reaction is well demonstrated on the parathormone-celiacogram. Thus a functional assessment of the hepatic blood flow is possible. The extent of the dilatability of the liver artery seems to be of great importance for the prognosis and indication of the porto-systemic shunt-operation. Moreover we could show that an increase in the liver perfusion demonstrates pathologic liver processes in a better way.

  18. The Effect of Elective Percutaneous Coronary Intervention of the Right Coronary Artery on Right Ventricular Function

    Directory of Open Access Journals (Sweden)

    Farahnaz Nikdoust

    2014-12-01

    Full Text Available Background: Right Ventricular (RV dysfunction has been introduced as a predictor of mortality in acute myocardial infarction. Objectives: This study aimed to investigate the effect of right coronary revascularization on systolic and diastolic RV dysfunction. Patients and Methods: This study was conducted on unstable angina patients who were candidate for elective Percutaneous Revascularization Intervention (PCI on the right coronary artery. The participants were initially evaluated by transthoracic echocardiography and tissue Doppler imaging prior to PCI and the RV function parameters were assessed. Echocardiography was repeated two months after PCI and the results were compared with baseline. Paired t-test was used to compare the pre- and post-procedural measurements. Besides, Pearson’s correlation was used to find out the linear association between the RV function parameters and Left Ventricular Ejection Fraction (LVEF. P value < 0.05 was considered as statistically significant. Results: This study was conducted on 30 patients (mean age = 60.00 ± 8.44 years; 24 [80%] males. In the pre-procedural echocardiography, 15 patients (50% had normal RV function, 14 patients (46.7% had grade-1 RV dysfunction, and only 1 patient (3.3% had grade-2 RV dysfunction. Following PCI, however, all the patients had normal systolic and diastolic RV functions. Comparison of echocardiographic RV function parameters showed an improvement in both systolic and diastolic functional parameters of the RV. Nonetheless, no significant correlation was observed between these parameters and Left Ventricular (LV function. Conclusions:: A significant improvement was found in RV function, but not LV function, after right coronary PCI. Revascularization of the right coronary artery may be beneficial for the patients who suffer from RV failure due to ischemia

  19. The efficacy of hemodialysis in interventional therapy in coronary artery disease patients with chronic renal insufficiency.

    Science.gov (United States)

    Zhai, Hongxia; Li, Liang; Yin, Yaxin; Zhang, Jinjin; Chen, Haiwei; Liu, Runmei; Xia, Yun-feng

    2016-01-01

    The aim of this study was to explore the efficacy and safety of hemodialysis in interventional therapy for patients with coronary artery disease combined with chronic renal insufficiency. With the aging and social development, the number of coronary artery disease patients with chronic renal insufficiency gradually increased. Total 58 coronary heart disease patients with chronic renal dysfunction were selected. These patients were characterized with typical angina symptoms and typical electrocardiogram (ECG) changes of onset angina. Continuous oral administration of sodium bicarbonate tablets 1 g 3/day × 3 days and slow intravenous input sodium chloride 1000 ∼1500 mL 3-12 h before operation were given. By this way, all patients were treated by hydration and alkalization. After percutaneous coronary intervention (PCI) treatment, patients were immediately transferred to undergo 4 h of dialysis treatment without removing indwelling of femoral artery puncture sheath tube to protect renal function. Changes in renal function including serum creatinine, glomerular filtration rate, and urine were observed and recorded. All patients were successfully underwent PCI treatment. Within one month after PCI, there were no obvious complication and no stent thrombosis occurred. Among of 58 patients, 56 cases showed no significant increase in serum creatinine levels compared with those before operation. However, serum creatinine level of one patient increased to 251 umol/L and one patient still required permanent dialysis. Using hemodialysis in interventional therapy in coronary artery disease patients with chronic renal insufficiency could significantly improve the prognosis of the patients.

  20. Sensitivity of the 252Cf(sf neutron observables to the FREYA input yield functions Y(A, Z, TKE

    Directory of Open Access Journals (Sweden)

    Randrup Jørgen

    2017-01-01

    Full Text Available Within the framework of the fission event generator FREYA, we are studying the sensitivity of various neutron observables to the yield distribution Y (A,Z,TKE used as input to the code. Concentrating on spontaneous fission of 252Cf, we have sampled a large number of different input yield functions based on χ2 fits to the experimental data on Y (A and Y (TKE|A. For each of these input yield distributions, we then use FREYA to generate a large sample of complete fission events from which we extract a variety of neutron observables, including the multiplicity distribution, the associated correlation coefficients, and its factorial moments, the dependence of the mean neutron multiplicity on the total fragment kinetic energy TKE and on the fragment mass number A, the neutron energy spectrum, and the two-neutron angular correlation function. In this way, we can determine the variation of these observables resulting from the uncertainties in the experimental mesurements. The imposition of a constraint on the resulting mean neutron multiplicity reduces the variation of the calculated neutron observables and provides a means for shrinking the uncertainties associated with the measured data.

  1. Sensitivity of the 252Cf(sf) neutron observables to the FREYA input yield functions Y(A, Z, TKE)

    Science.gov (United States)

    Randrup, Jørgen; Talou, Patrick; Vogt, Ramona

    2017-09-01

    Within the framework of the fission event generator FREYA, we are studying the sensitivity of various neutron observables to the yield distribution Y (A,Z,TKE) used as input to the code. Concentrating on spontaneous fission of 252Cf, we have sampled a large number of different input yield functions based on χ2 fits to the experimental data on Y (A) and Y (TKE|A). For each of these input yield distributions, we then use FREYA to generate a large sample of complete fission events from which we extract a variety of neutron observables, including the multiplicity distribution, the associated correlation coefficients, and its factorial moments, the dependence of the mean neutron multiplicity on the total fragment kinetic energy TKE and on the fragment mass number A, the neutron energy spectrum, and the two-neutron angular correlation function. In this way, we can determine the variation of these observables resulting from the uncertainties in the experimental mesurements. The imposition of a constraint on the resulting mean neutron multiplicity reduces the variation of the calculated neutron observables and provides a means for shrinking the uncertainties associated with the measured data.

  2. Sympathetic Innervation Promotes Arterial Fate by Enhancing Endothelial ERK Activity.

    Science.gov (United States)

    Pardanaud, Luc; Pibouin-Fragner, Laurence; Dubrac, Alexandre; Mathivet, Thomas; English, Isabel; Brunet, Isabelle; Simons, Michael; Eichmann, Anne

    2016-08-19

    Arterial endothelial cells are morphologically, functionally, and molecularly distinct from those found in veins and lymphatic vessels. How arterial fate is acquired during development and maintained in adult vessels is incompletely understood. We set out to identify factors that promote arterial endothelial cell fate in vivo. We developed a functional assay, allowing us to monitor and manipulate arterial fate in vivo, using arteries isolated from quails that are grafted into the coelom of chick embryos. Endothelial cells migrate out from the grafted artery, and their colonization of host arteries and veins is quantified. Here we show that sympathetic innervation promotes arterial endothelial cell fate in vivo. Removal of sympathetic nerves decreases arterial fate and leads to colonization of veins, whereas exposure to sympathetic nerves or norepinephrine imposes arterial fate. Mechanistically, sympathetic nerves increase endothelial ERK (extracellular signal-regulated kinase) activity via adrenergic α1 and α2 receptors. These findings show that sympathetic innervation promotes arterial endothelial fate and may lead to novel approaches to improve arterialization in human disease. © 2016 American Heart Association, Inc.

  3. Spontaneous indices are inconsistent with arterial baroreflex gain.

    Science.gov (United States)

    Lipman, Ruth D; Salisbury, Julie K; Taylor, J Andrew

    2003-10-01

    Spontaneously occurring, parallel fluctuations in arterial pressure and heart period are frequently used as indices of baroreflex function. Despite the convenience of spontaneous indices, their relation to the arterial baroreflex remains unclear. Therefore, in 97 volunteers, we derived 5 proposed indices (sequence method, alpha-index, transfer function, low-frequency transfer function, and impulse response function), compared them with arterial baroreflex gain (by the modified Oxford pharmacologic technique), and examined their relation to carotid distensibility and respiratory sinus arrhythmia. The subjects comprised men and women (n=41) aged 25 to 86 years, 30% of whom had established coronary artery disease. Generally, the indices were correlated with each other (except alpha-index and low-frequency transfer function) and with baroreflex gain. However, the Bland-Altman method demonstrated that the spontaneous indices had limits of agreement as large as the baroreflex gain itself. Even in individuals within the lowest tertile of baroreflex gain for whom baroreflex gain appears to be the most clinically relevant, spontaneous indices failed to relate to baroreflex gain. In fact, for these individuals, there was no correlation between any index and baroreflex gain. Forward stepwise linear regression showed that all spontaneous indices and baroreflex gain were related to respiratory sinus arrhythmia, but only baroreflex gain was related to carotid distensibility. Therefore, these data suggest that spontaneous indices are inadequate estimates of gain and are inconsistent with arterial baroreflex function.

  4. A randomised trial comparing the effect of exercise training and weight loss on microvascular function in coronary artery disease

    DEFF Research Database (Denmark)

    Olsen, Rasmus Huan; Pedersen, Lene Rørholm; Jürs, Anders

    2015-01-01

    BACKGROUND: Coronary microvascular function is associated with outcome and is reduced in coronary artery disease (CAD) and obesity. We compared the effect of aerobic interval training (AIT) and weight loss on coronary flow reserve (CFR) and peripheral vascular function in revascularised obese CAD...... patients. METHODS AND RESULTS: Seventy non-diabetic patients (BMI 28-40 kg × m(-2), age 45-75 years) were randomised to 12 weeks' AIT (three weekly sessions lasting 38 min with ≈ 16 min at 85-90% of VO2peak) or low energy diet (LED, 800-1000 kcal/day). Per protocol adherence was defined by training......-attendance ≥ 60% and weight loss ≥ 5%, respectively. CFR was assessed by Doppler echocardiography of the LAD. Peripheral vascular function was assessed by arterial tonometry as reactive hyperaemia index (RHI) and augmentation index. Most participants had impaired CFR with a mean CFR of 2.38 (SD 0.59). Twenty...

  5. A simple method for regional cerebral blood flow measurement by one-point arterial blood sampling and 123I-IMP microsphere model (part 2). A study of time correction of one-point blood sample count

    International Nuclear Information System (INIS)

    Masuda, Yasuhiko; Makino, Kenichi; Gotoh, Satoshi

    1999-01-01

    In our previous paper regarding determination of the regional cerebral blood flow (rCBF) using the 123 I-IMP microsphere model, we reported that the accuracy of determination of the integrated value of the input function from one-point arterial blood sampling can be increased by performing correction using the 5 min: 29 min ratio for the whole-brain count. However, failure to carry out the arterial blood collection at exactly 5 minutes after 123 I-IMP injection causes errors with this method, and there is thus a time limitation. We have now revised out method so that the one-point arterial blood sampling can be performed at any time during the interval between 5 minutes and 20 minutes after 123 I-IMP injection, with addition of a correction step for the sampling time. This revised method permits more accurate estimation of the integral of the input functions. This method was then applied to 174 experimental subjects: one-point blood samples collected at random times between 5 and 20 minutes, and the estimated values for the continuous arterial octanol extraction count (COC) were determined. The mean error rate between the COC and the actual measured continuous arterial octanol extraction count (OC) was 3.6%, and the standard deviation was 12.7%. Accordingly, in 70% of the cases, the rCBF was able to be estimated within an error rate of 13%, while estimation was possible in 95% of the cases within an error rate of 25%. This improved method is a simple technique for determination of the rCBF by 123 I-IMP microsphere model and one-point arterial blood sampling which no longer shows a time limitation and does not require any octanol extraction step. (author)

  6. Quantification of regional cerebral blood flow (rCBF) measurement with one point sampling by sup 123 I-IMP SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Munaka, Masahiro [University of Occupational and Enviromental Health, Kitakyushu (Japan); Iida, Hidehiro; Murakami, Matsutaro

    1992-02-01

    A handy method of quantifying regional cerebral blood flow (rCBF) measurement by {sup 123}I-IMP SPECT was designed. A standard input function was made and the sampling time to calibrate this standard input function by one point sampling was optimized. An average standard input function was obtained from continuous arterial samplings of 12 healthy adults. The best sampling time was the minimum differential value between the integral calculus value of the standard input function calibrated by one point sampling and the input funciton by continuous arterial samplings. This time was 8 minutes after an intravenous injection of {sup 123}I-IMP and an error was estimated to be {+-}4.1%. The rCBF values by this method were evaluated by comparing them with the rCBF values of the input function with continuous arterial samplings in 2 healthy adults and a patient with cerebral infarction. A significant correlation (r=0.764, p<0.001) was obtained between both. (author).

  7. Effects of Clopidogrel Therapy on Oxidative Stress, Inflammation, Vascular Function and Progenitor Cells in Stable Coronary Artery Disease

    Science.gov (United States)

    Ramadan, Ronnie; Dhawan, Saurabh S.; Syed, Hamid; Pohlel, F. Khan; Binongo, Jose Nilo G.; Ghazzal, Ziyad B.; Quyyumi, Arshed A.

    2014-01-01

    Background Traditional cardiovascular risk factors lead to endothelial injury and activation of leucocytes and platelets that initiate and propagate atherosclerosis. We proposed that clopidogrel therapy in patients with stable CAD imparts a pleiotropic effect that extends beyond anti-platelet aggregation to other athero-protective processes. Methods Forty-one subjects were randomized in a double-blind, placebo-controlled crossover study to either clopidogrel 75 mg daily or placebo for 6-weeks, and then transitioned immediately to the other treatment for an additional 6 weeks. We assessed 1) endothelial function as flow-mediated dilation of the brachial artery, 2) arterial stiffness and central augmentation index using applanation tonometry, 3) vascular function as fingertip reactive hyperemia index, 4) inflammation by measuring plasma CD40 ligand and serum high-sensitivity c-reactive protein levels, 5) oxidative stress by measuring plasma aminothiols, and 6) circulating progenitor cells, at baseline and at the end of each 6-week treatment period. Results Clopidogrel therapy resulted in a significant reduction in soluble CD40 ligand (p=0.03), a pro-thrombotic and pro-inflammatory molecule derived mainly from activated platelets. However, clopidogrel therapy had no effect on endothelial function, arterial stiffness, inflammatory and oxidative stress markers, or progenitor cells. Conclusions Our findings suggest a solitary anti-platelet effect of clopidogrel therapy in patients with stable CAD, with no effect on other sub-clinical markers of cardiovascular disease risk. PMID:24336012

  8. The future of collateral artery research

    NARCIS (Netherlands)

    Hakimzadeh, Nazanin; Verberne, Hein J.; Siebes, Maria; Piek, Jan J.

    2014-01-01

    In the event of obstructive coronary artery disease, collateral arteries have been deemed an alternative blood source to preserve myocardial tissue perfusion and function. Monocytes play an important role in modulating this process, by local secretion of growth factors and extracellular matrix

  9. Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress

    NARCIS (Netherlands)

    Harms, M.P.M.; Wesseling, K.H.; Pott, F.; Jenstrup, M.; Goudoever, J. van; Secher, N.H.; Lieshout, J.J. van

    1999-01-01

    The relationship between aortic flow and pressure is described by a three-element model of the arterial input impedance, including continuous correction for variations in the diameter and the compliance of the aorta (Modelflow). We computed the aortic flow from arterial pressure by this model, and

  10. Cardiovascular risk factors and collateral artery formation.

    Science.gov (United States)

    de Groot, D; Pasterkamp, G; Hoefer, I E

    2009-12-01

    Arterial lumen narrowing and vascular occlusion is the actual cause of morbidity and mortality in atherosclerotic disease. Collateral artery formation (arteriogenesis) refers to an active remodelling of non-functional vascular anastomoses to functional collateral arteries, capable to bypass the site of obstruction and preserve the tissue that is jeopardized by ischaemia. Hemodynamic forces such as shear stress and wall stress play a pivotal role in collateral artery formation, accompanied by the expression of various cytokines and invasion of circulating leucocytes. Arteriogenesis hence represents an important compensatory mechanism for atherosclerotic vessel occlusion. As arteriogenesis mostly occurs when lumen narrowing by atherosclerotic plaques takes place, presence of cardiovascular risk factors (e.g. hypertension, hypercholesterolaemia and diabetes) is highly likely. Risk factors for atherosclerotic disease affect collateral artery growth directly and indirectly by altering hemodynamic forces or influencing cellular function and proliferation. Adequate collateralization varies significantly among atherosclerotic patients, some profit from the presence of extensive collateral networks, whereas others do not. Cardiovascular risk factors could increase the risk of adverse cardiovascular events in certain patients because of the reduced protection through an alternative vascular network. Likewise, drugs primarily thought to control cardiovascular risk factors might contribute or counteract collateral artery growth. This review summarizes current knowledge on the influence of cardiovascular risk factors and the effects of cardiovascular medication on the development of collateral vessels in experimental and clinical studies.

  11. Purple grape juice improves endothelial function and reduces the susceptibility of LDL cholesterol to oxidation in patients with coronary artery disease.

    Science.gov (United States)

    Stein, J H; Keevil, J G; Wiebe, D A; Aeschlimann, S; Folts, J D

    1999-09-07

    In vitro, the flavonoid components of red wine and purple grape juice are powerful antioxidants that induce endothelium-dependent vasodilation of vascular rings derived from rat aortas and human coronary arteries. Although improved endothelial function and inhibition of LDL oxidation may be potential mechanisms by which red wine and flavonoids reduce cardiovascular risk, the in vivo effects of grape products on endothelial function and LDL oxidation have not been investigated. This study assessed the effects of ingesting purple grape juice on endothelial function and LDL susceptibility to oxidation in patients with coronary artery disease (CAD). Fifteen adults with angiographically documented CAD ingested 7.7+/-1.2 mL. kg(-1). d(-1) of purple grape juice for 14 days. Flow-mediated vasodilation (FMD) was measured using high-resolution brachial artery ultrasonography. Susceptibility of LDL particles to oxidation was determined from the rate of conjugated diene formation after exposure to copper chloride. At baseline, FMD was impaired (2.2+/-2. 9%). After ingestion of grape juice, FMD increased to 6.4+/-4.7% (P=0.003). In a linear regression model that included age, artery diameter, lipid values, and use of lipid-lowering and antioxidant therapies, the effect of grape juice on FMD remained significant (mean change 4.2+/-4.4%, PFMD and reduces LDL susceptibility to oxidation in CAD patients. Improved endothelium-dependent vasodilation and prevention of LDL oxidation are potential mechanisms by which flavonoids in purple grape products may prevent cardiovascular events, independent of alcohol content.

  12. Renal Artery Stenosis (RAS) Case study

    International Nuclear Information System (INIS)

    Zaater, M.K.

    2012-01-01

    Renal Artery Stenosis (RAS), is one of the causes of secondary hypertension; there are many causes of renal artery stenosis, as atherosclerosis of the renal artery which account for 90% of cases of RAS; fibromuscular dysplasia accounts for 10% of RAS. Various causes of thrombophilia either due congenital causes or acquired causes and can lead to RAS. Our patient was presented by acute attack of epistaxis and hypertension. Angiography of the Renal Arteries,are showed no sign of renal artery stenosis. However, the right kidney showed upper pole infarction, and the left kidney showed evidence of functional lower pole renal artery stenosis, although there is no anatomical stenosis detected in angiography. Work up for the cause of thrombophilia did not help in the diagnosis, which may be due to an undiscovered cause of thrombophilia

  13. The Effect of Milrinone on the Right Ventriclular Function in Patients with Reduced Right Ventricular Function Undergoing Off-pump Coronary Artery Bypass Graft Surgery

    Science.gov (United States)

    Lee, Jong Hwa; Oh, Young Jun; Shim, Yon Hee; Hong, Yong Woo; Yi, Gijong

    2006-01-01

    This investigation evaluated the effect of continuous milrinone infusion on right ventriclular (RV) function during off-pump coronary artery bypass graft (OPCAB) surgery in patients with reduced RV function. Fifty patients scheduled for OPCAB, with thermodilution RV ejection fraction (RVEF) milrinone (0.5 µg/kg/min) or control (saline) group. Hemodynamic variables and RV volumetric data measured by thermodilution method were collected as follows: after anesthesia induction (T1); 10 min after heart displacement for obtuse marginal artery anastomosis (T2); after pericardial closure (T3). Cardiac index and heart rate increased and systemic vascular resistance significantly decreased in milrinone group at T2. Initially lower RVEF of milrinone group was eventually comparable to control group after milrinone infusion. RVEF did not significantly change at T2 and T3 in both groups. RV end-diastolic volume in milrinone group consistently decreased from the baseline at T2 and T3. Continuous infusion of milrinone without a bolus demonstrated potentially beneficial effect on cardiac output and RV afterload in patients with reduced RV function during OPCAB. However, aggressive augmentation of intravascular volume seems to be necessary to maximize the effect of the milrinone in these patients. PMID:17043419

  14. Arterial wave reflection and subclinical left ventricular systolic dysfunction.

    Science.gov (United States)

    Russo, Cesare; Jin, Zhezhen; Takei, Yasuyoshi; Hasegawa, Takuya; Koshaka, Shun; Palmieri, Vittorio; Elkind, Mitchell Sv; Homma, Shunichi; Sacco, Ralph L; Di Tullio, Marco R

    2011-03-01

    Increased arterial wave reflection is a predictor of cardiovascular events and has been hypothesized to be a cofactor in the pathophysiology of heart failure. Whether increased wave reflection is inversely associated with left-ventricular (LV) systolic function in individuals without heart failure is not clear. Arterial wave reflection and LV systolic function were assessed in 301 participants from the Cardiovascular Abnormalities and Brain Lesions (CABL) study using two-dimensional echocardiography and applanation tonometry of the radial artery to derive central arterial waveform by a validated transfer function. Aortic augmentation index (AIx) and wasted energy index (WEi) were used as indices of wave reflection. LV systolic function was measured by LV ejection fraction (LVEF) and tissue Doppler imaging (TDI). Mitral annulus peak systolic velocity (Sm), peak longitudinal strain and strain rate were measured. Participants with history of coronary artery disease, atrial fibrillation, LVEF less than 50% or wall motion abnormalities were excluded. Mean age of the study population was 68.3 ± 10.2 years (64.1% women, 65% hypertensive). LV systolic function by TDI was lower with increasing wave reflection, whereas LVEF was not. In multivariate analysis, TDI parameters of LV longitudinal systolic function were significantly and inversely correlated to AIx and WEi (P values from 0.05 to 0.002). In a community cohort without heart failure and with normal LVEF, an increased arterial wave reflection was associated with subclinical reduction in LV systolic function assessed by novel TDI techniques. Further studies are needed to investigate the prognostic implications of this relationship.

  15. Netrin-1 controls sympathetic arterial innervation.

    Science.gov (United States)

    Brunet, Isabelle; Gordon, Emma; Han, Jinah; Cristofaro, Brunella; Broqueres-You, Dong; Liu, Chun; Bouvrée, Karine; Zhang, Jiasheng; del Toro, Raquel; Mathivet, Thomas; Larrivée, Bruno; Jagu, Julia; Pibouin-Fragner, Laurence; Pardanaud, Luc; Machado, Maria J C; Kennedy, Timothy E; Zhuang, Zhen; Simons, Michael; Levy, Bernard I; Tessier-Lavigne, Marc; Grenz, Almut; Eltzschig, Holger; Eichmann, Anne

    2014-07-01

    Autonomic sympathetic nerves innervate peripheral resistance arteries, thereby regulating vascular tone and controlling blood supply to organs. Despite the fundamental importance of blood flow control, how sympathetic arterial innervation develops remains largely unknown. Here, we identified the axon guidance cue netrin-1 as an essential factor required for development of arterial innervation in mice. Netrin-1 was produced by arterial smooth muscle cells (SMCs) at the onset of innervation, and arterial innervation required the interaction of netrin-1 with its receptor, deleted in colorectal cancer (DCC), on sympathetic growth cones. Function-blocking approaches, including cell type-specific deletion of the genes encoding Ntn1 in SMCs and Dcc in sympathetic neurons, led to severe and selective reduction of sympathetic innervation and to defective vasoconstriction in resistance arteries. These findings indicate that netrin-1 and DCC are critical for the control of arterial innervation and blood flow regulation in peripheral organs.

  16. Implication of molecular vascular smooth muscle cell heterogeneity among arterial beds in arterial calcification.

    Directory of Open Access Journals (Sweden)

    Olivier Espitia

    Full Text Available Vascular calcification is a strong and independent predictive factor for cardiovascular complications and mortality. Our previous work identified important discrepancies in plaque composition and calcification types between carotid and femoral arteries. The objective of this study is to further characterize and understand the heterogeneity in vascular calcification among vascular beds, and to identify molecular mechanisms underlying this process. We established ECLAGEN biocollection that encompasses human atherosclerotic lesions and healthy arteries from different locations (abdominal, thoracic aorta, carotid, femoral, and infrapopliteal arteries for histological, cell isolation, and transcriptomic analysis. Our results show that lesion composition differs between these locations. Femoral arteries are the most calcified arteries overall. They develop denser calcifications (sheet-like, nodule, and are highly susceptible to osteoid metaplasia. These discrepancies may derive from intrinsic differences between SMCs originating from these locations, as microarray analysis showed specific transcriptomic profiles between primary SMCs isolated from each arterial bed. These molecular differences translated into functional disparities. SMC from femoral arteries showed the highest propensity to mineralize due to an increase in basal TGFβ signaling. Our results suggest that biological heterogeneity of resident vascular cells between arterial beds, reflected by our transcriptomic analysis, is critical in understanding plaque biology and calcification, and may have strong implications in vascular therapeutic approaches.

  17. Ultra-low input transcriptomics reveal the spore functional content and phylogenetic affiliations of poorly studied arbuscular mycorrhizal fungi.

    Science.gov (United States)

    Beaudet, Denis; Chen, Eric C H; Mathieu, Stephanie; Yildirir, Gokalp; Ndikumana, Steve; Dalpé, Yolande; Séguin, Sylvie; Farinelli, Laurent; Stajich, Jason E; Corradi, Nicolas

    2017-12-02

    Arbuscular mycorrhizal fungi (AMF) are a group of soil microorganisms that establish symbioses with the vast majority of land plants. To date, generation of AMF coding information has been limited to model genera that grow well axenically; Rhizoglomus and Gigaspora. Meanwhile, data on the functional gene repertoire of most AMF families is non-existent. Here, we provide primary large-scale transcriptome data from eight poorly studied AMF species (Acaulospora morrowiae, Diversispora versiforme, Scutellospora calospora, Racocetra castanea, Paraglomus brasilianum, Ambispora leptoticha, Claroideoglomus claroideum and Funneliformis mosseae) using ultra-low input ribonucleic acid (RNA)-seq approaches. Our analyses reveals that quiescent spores of many AMF species harbour a diverse functional diversity and solidify known evolutionary relationships within the group. Our findings demonstrate that RNA-seq data obtained from low-input RNA are reliable in comparison to conventional RNA-seq experiments. Thus, our methodology can potentially be used to deepen our understanding of fungal microbial function and phylogeny using minute amounts of RNA material. © The Author 2017. Published by Oxford University Press on behalf of Kazusa DNA Research Institute.

  18. Magnetic resonance imaging of athlete's heart: myocardial mass, left ventricular function, and cross-sectional area of the coronary arteries

    International Nuclear Information System (INIS)

    Zandrino, F.; Sardanelli, F.; Molinari, G.; Masperone, M.A.; Smeraldi, A.; Odaglia, G.

    2000-01-01

    To evaluate left ventricular myocardial mass and function as well as ostial coronary artery cross-sectional area in endurance athletes, an athlete group of 12 highly trained rowers and a control group of 12 sedentary healthy subjects underwent MR examination. An ECG-gated breath-hold cine gradient-echo sequence was used to calculate myocardial mass, end-diastolic and end-systolic volumes, stroke volume, and cardiac output, all related to body surface area, as well as ejection fraction. A 3D fat-saturated ECG- and respiratory-triggered navigator echo sequence was used to evaluate coronary arteries: left main (LM), left anterior descending (LAD), left circumflex (LCx), and right coronary artery (RCA). Cross-sectional area was calculated and divided for body surface area. Myocardial mass was found significantly larger in athlete group than in control group (p = 0.0078), the same being for end-diastolic volume (p = 0.0078), stroke volume (p = 0.0055), LM (p = 0.0066) and LAD (p = 0.0129). No significant difference was found for all the remaining parameters. Significant correlation with myocardial mass was found for LM (p < 0.001) and LAD (p = 0.0340), not for LCx and RCA. Magnetic resonance imaging is a useful tool in evaluating the myocardial hypertrophy and function of athlete's heart. Magnetic resonance angiography is a valuable noninvasive method to visualize the correlated cross-sectional area increase of the left coronary artery system. (orig.)

  19. Functional ET(A)-ET(B) Receptor Cross-talk in Basilar Artery In Situ From ET(B) Receptor Deficient Rats.

    Science.gov (United States)

    Yoon, SeongHun; Gariepy, Cheryl E; Yanagisawa, Masashi; Zuccarello, Mario; Rapoport, Robert M

    2016-03-01

    The role of endothelin (ET)(A)-ET(B) receptor cross-talk in limiting the ET(A) receptor antagonist inhibition of ET-1 constriction is revealed by the partial or complete dependency of the ET(A) receptor antagonist inhibition on functional removal of the ET(B) receptor. Although functional removal of the ET(B) receptor is generally accomplished with ET(B) receptor antagonist, a novel approach using rats containing a naturally occurring deletion mutation in the ET(B) receptor [rescued "spotting lethal" (sl) rats; ET(B)(sl/sl)] demonstrated increased ET(A) receptor antagonist inhibition of ET-1 constriction in vena cava. We investigated whether this deletion mutation was also sufficient to remove the ET(B) receptor dependency of the ET(A) receptor antagonist inhibition of ET-1 constriction in the basilar artery. Consistent with previous reports, ET-1 plasma levels were elevated in ET(B)(sl/sl) as compared with ET(B)(+/+) rats. ET(B) receptor antagonist failed to relax the ET-1 constricted basilar artery from ET(B)(+/+) and ET(B)(sl/sl) rats. Relaxation to combined ET(A) and ET(B) receptor antagonist was greater than relaxation to ET(A) receptor antagonist in the basilar artery from ET(B)(+/+) and, unexpectedly, ET(B)(sl/sl) rats. These findings confirm the presence of ET(A)-ET(B) receptor cross-talk in the basilar artery. We speculate that mutant ET(B) receptor expression produced by alternative splicing may be sufficient to allow cross-talk.

  20. Radioindication of hemodynamics and functional state of parenchyma of the kidneys in stenosis of renal arteries

    International Nuclear Information System (INIS)

    Efimov, O.N.; Gabuniya, R.I.; Kamynin, Yu.F.; Matveenko, E.G.; Buyuklyan, A.N.; Skoropad, L.S.; Syzgantseva, L.M.

    1978-01-01

    Hemodynamics and functional state of parenchyma of the kidney were studied in 39 patients with stenosis of the renal arteries by means of pertechnetate 99 Tc, hippuran 131 I and chlormerodrine 197 Hg. In patients with vasorenal hypertension the following changes in the stenosed kidney were revealed: a significant decrease in the renal blood flow, renal fraction, volume of maximal saturation, specific blood flow, systolic renal index; elevation of the intrarenal vascular resistance; and impairment of the functional state of the renal parenchyma. It was established that there was a direct dependence between the renal blood flow and the volume of maximal saturation and a reverse dependence between the renal blood flow and intrarenal vascular resistance. Hemodynamic changes in the stenosed kidney played an important role and led at first to a bias in renographic indices and then - to a decrease in accumulation of chlormerodrine 197 Hg in the kidneys. It was noted that changes in the functional state of the renal parenchyma tended to be dependent upon the level of the renal blood flow, and indices of the renal blood flow - upon the values of arterial pressure. From diagnostic point of view, methods of radioiangiography, as compared with renography and scintigraphy, were found to be the most informative

  1. The influence of anatomic variance in the coronary artery on cardiac function with PCI after acute inferior wall myocardial infarction

    International Nuclear Information System (INIS)

    Zheng Hongming; Feng Jue; Fang Fengning; Wu Heping; Wang Fengqin; Ma Huili

    2006-01-01

    Objective: To analyze the influence in anatomic variance of coronary artery on function of left and right ventricles after acute inferior myocardial infarction (AIMI) treated with percutaneous coronary intervention therapy (PCI). Methods: Forty-seven inferior AIMI patients were divided into 2 groups: 12 left dominant group [including equipollent case, i.e. inferior wall of left ventricle supplied by left circumflex coronary artery (LCX), right ventricle by right coronary artery (RCA)] and 35 right dominant group (both inferior wall and right ventricle were supplied by RCA). Equilibrium radionuclide angiocardiography (ERNA) and myocardial perfusion imaging (MPI) were used for comparing the influence between different coronary artery flow patterns on biventricular hemodynamics, blood supply and prognosis of PCI after 3 months. Results: Comparison of ventricular function in left and right dominant coronal artery type groups discharged 7- 10 d after PCI, there were differences in left ventricular ejection fraction (LVEF) [(63.03 ± 5.64)% vs (57.67 ± 7.35)%, P=0.012], peak ejection rate (PER) [(3.52 ± 0.66) end-diastolic volume (EDV)/s vs (2.93 ± 0.73) EDV/s, P =0.011], peak filling rate (PFR) [(2.71 ± 0.88) EDV/s vs (2.11 ± 0.45 ) EDV/s, P=0.004], left free-wall regional ejection fraction [(81.94 ± 20.75)% vs (67.25 ± 16.54)%, P = O.032], and right free-wall regional ejection fraction [(57.86 ± 11.77)% vs (67.83 ± 10.38)%, P=0.012], right ventricular ejection fraction (RVEF) [(37.89 ± 3.86)% vs (41.67 ± 4.81)%, P=0.09]. After 3 months,there was difference only in RVEF [(44.60 ± 5.29)% vs (48.00 ± 3.30)%, P=0.043], but no difference in myocardial perfusion of left ventricle (P=0.357). Conclusions: In acute stage of AIMI right dominant group, there was more severe injury of right ventricle, in convalescent stage most of the right ventricular function resumed. The sustained right ventricular function in part of the patients can be demonstrated by ERNA

  2. Pulmonary artery radiocardiography and rheography in the diagnosis of hemodynamic and contractile function impairments of the right ventricle in patients with obstructive bronchitis

    International Nuclear Information System (INIS)

    Paleev, N.P.; Cherejskaya, N.K.; Tsar'kova, L.N.; Baklykova, S.N.; Novoderezhkina, L.B.; Oblovatskaya, O.G.; Dubinina, E.B.

    1990-01-01

    Radiocardiography and rheography of the pulmonary artery were used to examine impairments in hemodynamics and contractile function of the right ventricle in 40 patients with chronic obstructive bronchitis complicated with persistent hypertension. Right ventricular hemodynamic and contractile impairments were shown to be not equivalent with similar clinical and functional signs of pulmonary hypertension. This fact indicates that the use of special techiques is of practical value in the determination of right ventricular hemodynamics and myocardial contractility in patients with chronic obstructive bronchitis. Radiocardiography and rheography of the pulmonary artery are sufficiently reliable noninvasive techniques for examining the hemodynamics and contractile function of the right ventricular myocardium

  3. “Transcollateral” Renal Angioplasty for a Completely Occluded Renal Artery

    International Nuclear Information System (INIS)

    Chandra, Subash; Chadha, Davinder S.; Swamy, Ajay

    2011-01-01

    Percutaneous transluminal renal angioplasty with stenting has been effective in the control of hypertension, renal function, and pulmonary edema caused by atherosclerotic renal artery stenosis. However, the role of the procedure has not been fully established in the context of chronic total occlusion of renal artery. We report the successful use of this procedure in 57-year-old male patient who reported for evaluation of a recent episode of accelerated hypertension. A renal angiogram in this patient showed ostial stenosis of the right renal artery, which was filling by way of the collateral artery. Renal angioplasty for chronic total occlusion of right renal artery was successfully performed in a retrograde fashion through a collateral artery, thereby leading to improvement of renal function and blood pressure control.

  4. Pulmonary artery wave propagation and reservoir function in conscious man: impact of pulmonary vascular disease, respiration and dynamic stress tests

    DEFF Research Database (Denmark)

    Su, Junjing; Manisty, Charlotte; Simonsen, Ulf

    2017-01-01

    Detailed haemodynamic analysis may provide novel insights into the pulmonary circulation. Therefore, wave intensity and reservoir-excess pressure analyses were applied in the pulmonary artery to characterize changes in wave propagation and reservoir function during spontaneous respiration......, recordings were also obtained during Valsalva manoeuvre and handgrip exercise. The asymptotic pressure at which the flow through the microcirculation ceases, the reservoir pressure related to arterial compliance and the excess pressure caused by arterial waves increased in PAH patients compared to controls....... The systolic and diastolic rate constants also increased, while the diastolic time constant decreased. The forward compression wave energy decreased by ∼8% in controls and ∼6% in PAH patients during expiration compared to inspiration, while the wave speed remained unchanged throughout the respiratory cycle...

  5. Targeted deletion of neurokinin-1 receptor expressing nucleus tractus solitarii neurons precludes somatosensory depression of arterial baroreceptor-heart rate reflex.

    Science.gov (United States)

    Potts, J T; Fong, A Y; Anguelov, P I; Lee, S; McGovern, D; Grias, I

    2007-03-30

    NTS. These findings indicate that immunolesioning of NK1-R expressing NTS neurons selectively abolishes the depressive effect of somatosensory input on arterial baroreceptor-heart rate reflex function.

  6. Estimation of Pulse Transit Time as a Function of Blood Pressure Using a Nonlinear Arterial Tube-Load Model.

    Science.gov (United States)

    Gao, Mingwu; Cheng, Hao-Min; Sung, Shih-Hsien; Chen, Chen-Huan; Olivier, Nicholas Bari; Mukkamala, Ramakrishna

    2017-07-01

    pulse transit time (PTT) varies with blood pressure (BP) throughout the cardiac cycle, yet, because of wave reflection, only one PTT value at the diastolic BP level is conventionally estimated from proximal and distal BP waveforms. The objective was to establish a technique to estimate multiple PTT values at different BP levels in the cardiac cycle. a technique was developed for estimating PTT as a function of BP (to indicate the PTT value for every BP level) from proximal and distal BP waveforms. First, a mathematical transformation from one waveform to the other is defined in terms of the parameters of a nonlinear arterial tube-load model accounting for BP-dependent arterial compliance and wave reflection. Then, the parameters are estimated by optimally fitting the waveforms to each other via the model-based transformation. Finally, PTT as a function of BP is specified by the parameters. The technique was assessed in animals and patients in several ways including the ability of its estimated PTT-BP function to serve as a subject-specific curve for calibrating PTT to BP. the calibration curve derived by the technique during a baseline period yielded bias and precision errors in mean BP of 5.1 ± 0.9 and 6.6 ± 1.0 mmHg, respectively, during hemodynamic interventions that varied mean BP widely. the new technique may permit, for the first time, estimation of PTT values throughout the cardiac cycle from proximal and distal waveforms. the technique could potentially be applied to improve arterial stiffness monitoring and help realize cuff-less BP monitoring.

  7. Nonischemic changes in right ventricular function on exercise. Do normal volunteers differ from patients with normal coronary arteries

    International Nuclear Information System (INIS)

    Caplin, J.L.; Maltz, M.B.; Flatman, W.D.; Dymond, D.S.

    1988-01-01

    Factors other than ischemia may alter right ventricular function both at rest and on exercise. Normal volunteers differ from cardiac patients with normal coronary arteries with regard to their left ventricular response to exercise. This study examined changes in right ventricular function on exercise in 21 normal volunteers and 13 patients with normal coronary arteries, using first-pass radionuclide angiography. There were large ranges of right ventricular ejection fraction in the two groups, both at rest and on exercise. Resting right ventricular ejection fraction was 40.2 +/- 10.6% (mean +/- SD) in the volunteers and 38.6 +/- 9.7% in the patients, p = not significant, and on exercise rose significantly in both groups to 46.1 +/- 9.9% and 45.8 +/- 9.7%, respectively. The difference between the groups was not significant. In both groups some subjects with high resting values showed large decreases in ejection fraction on exercise, and there were significant negative correlations between resting ejection fraction and the change on exercise, r = -0.59 (p less than 0.01) in volunteers, and r = -0.66 (p less than 0.05) in patients. Older volunteers tended to have lower rest and exercise ejection fractions, but there was no difference between normotensive and hypertensive patients in their rest or exercise values. In conclusion, changes in right ventricular function on exercise are similar in normal volunteers and in patients with normal coronary arteries. Some subjects show decreases in right ventricular ejection fraction on exercise which do not appear to be related to ischemia

  8. The genetic basis for altered blood vessel function in disease: large artery stiffening

    Directory of Open Access Journals (Sweden)

    Alex Agrotis

    2005-12-01

    Full Text Available Alex AgrotisThe Cell Biology Laboratory, Baker Heart Research Institute, Melbourne, Victoria, AustraliaAbstract: The progressive stiffening of the large arteries in humans that occurs during aging constitutes a potential risk factor for increased cardiovascular morbidity and mortality, and is accompanied by an elevation in systolic blood pressure and pulse pressure. While the underlying basis for these changes remains to be fully elucidated, factors that are able to influence the structure and composition of the extracellular matrix and the way it interacts with arterial smooth muscle cells could profoundly affect the properties of the large arteries. Thus, while age and sex represent important factors contributing to large artery stiffening, the variation in growth-stimulating factors and those that modulate extracellular production and homeostasis are also being increasingly recognized to play a key role in the process. Therefore, elucidating the contribution that genetic variation makes to large artery stiffening could ultimately provide the basis for clinical strategies designed to regulate the process for therapeutic benefit.Keywords: arterial stiffness, genes, polymorphism, extracellular matrix proteins

  9. Perfusion CT compared to H{sub 2}{sup 15}O/O{sup 15}O PET in patients with chronic cervical carotid artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Kamath, Amita; Chien, Jeffrey D.; Dillon, William P.; Wintermark, Max [University of California, San Francisco, Department of Radiology, Neuroradiology Section, San Francisco, CA (United States); Smith, Wade S. [University of California, Department of Neurology, San Francisco, CA (United States); Powers, William J. [University of North Carolina, Department of Neurology, Chapel Hill, NC (United States); Cianfoni, Alessandro [Catholic University of Sacred Heart, Department of Bioimages and Radiological Sciences, Rome (Italy); Videen, Tom [Washington University School of Medicine, Departments of Neurology and Radiology, St. Louis, MO (United States); Lawton, Michael T. [University of California, San Francisco, CA (United States). Department of Neurosurgery; Finley, Bruce [Northern California PET Imaging Center, Sacramento, CA (United States)

    2008-09-15

    The purpose of this study was to compare the results of perfusion computed tomography (PCT) with those of {sup 15}O{sub 2}/H{sub 2}{sup 15}O positron emission tomography (PET) in a subset of Carotid Occlusion Surgery Study (COSS) patients. Six patients enrolled in the COSS underwent a standard-of-care PCT in addition to the {sup 15}O{sub 2}/H{sub 2}{sup 15}O PET study used for selection for extracranial-intracranial bypass surgery. PCT and PET studies were coregistered and then processed separately by different radiologists. Relative measurement of cerebral blood flow (CBF) and oxygen extraction fraction (OEF) were calculated from PET. PCT datasets were processed using different arterial input functions (AIF). Relative PCT and PET CBF values from matching regions of interest were compared using linear regression model to determine the most appropriate arterial input function for PCT. Also, PCT measurements using the most accurate AIF were evaluated for linear regression with respect to relative PET OEF values. The most accurate PCT relative CBF maps with respect to the gold standard PET CBF were obtained when CBF values for each arterial territory are calculated using a dedicated AIF for each territory (R{sup 2}=0.796, p<0.001). PCT mean transit time (MTT) is the parameter that showed the best correlation with the count-based PET OEF ratios (R{sup 2}=0.590, p<0.001). PCT relative CBF compares favorably to PET relative CBF in patients with chronic carotid occlusion when processed using a dedicated AIF for each territory. The PCT MTT parameter correlated best with PET relative OEF. (orig.)

  10. Pressure Myography to Study the Function and Structure of isolated small arteries

    DEFF Research Database (Denmark)

    Schjørring, Olav; Carlsson, Rune; Simonsen, Ulf

    2015-01-01

    Small arteries play an important role in regulation of peripheral resistance and organ perfusion. Here we describe a series of the methods allowing measurements in pressurized segments of small arteries from the systemic and coronary circulation of mice as well as other species. The pressure...... myography techniques described include measurements of wall structure, wall stress, strain, and of myogenic tone. The pressurized perfused small arteries also allow evaluation of responses to increases in pressure, flow, and drugs, where the main readout is changes in vascular diameter....

  11. Anomalous left coronary artery from the pulmonary artery with a large patent ductus arteriosus: aversion of a catastrophe.

    Science.gov (United States)

    Aggarwal, Sanjeev; Delius, Ralph E; Pettersen, Michael D

    2013-01-01

    We present an infant who had an anomalous left coronary artery arising from the pulmonary artery (ALCAPA) and a large patent ductus arteriosus (PDA), who was diagnosed before a potentially catastrophic closure of PDA. In the presence of normal left ventricular function and the absence of coronary artery collaterals, it is difficult to diagnose ALCAPA. A disproportionate degree of left ventricular dilation and severity of mitral valve regurgitation relative to the degree of PDA shunt, and echogenic papillary muscles on an echocardiogram should raise a suspicion of coronary artery anomalies. The infant underwent surgical ligation of PDA with translocation of coronary arteries and had an uneventful recovery. © 2012 Wiley Periodicals, Inc.

  12. Colchicine Depolymerizes Microtubules, Increases Junctophilin-2, and Improves Right Ventricular Function in Experimental Pulmonary Arterial Hypertension.

    Science.gov (United States)

    Prins, Kurt W; Tian, Lian; Wu, Danchen; Thenappan, Thenappan; Metzger, Joseph M; Archer, Stephen L

    2017-05-31

    Pulmonary arterial hypertension (PAH) is a lethal disease characterized by obstructive pulmonary vascular remodeling and right ventricular (RV) dysfunction. Although RV function predicts outcomes in PAH, mechanisms of RV dysfunction are poorly understood, and RV-targeted therapies are lacking. We hypothesized that in PAH, abnormal microtubular structure in RV cardiomyocytes impairs RV function by reducing junctophilin-2 (JPH2) expression, resulting in t-tubule derangements. Conversely, we assessed whether colchicine, a microtubule-depolymerizing agent, could increase JPH2 expression and enhance RV function in monocrotaline-induced PAH. Immunoblots, confocal microscopy, echocardiography, cardiac catheterization, and treadmill testing were used to examine colchicine's (0.5 mg/kg 3 times/week) effects on pulmonary hemodynamics, RV function, and functional capacity. Rats were treated with saline (n=28) or colchicine (n=24) for 3 weeks, beginning 1 week after monocrotaline (60 mg/kg, subcutaneous). In the monocrotaline RV, but not the left ventricle, microtubule density is increased, and JPH2 expression is reduced, with loss of t-tubule localization and t-tubule disarray. Colchicine reduces microtubule density, increases JPH2 expression, and improves t-tubule morphology in RV cardiomyocytes. Colchicine therapy diminishes RV hypertrophy, improves RV function, and enhances RV-pulmonary artery coupling. Colchicine reduces small pulmonary arteriolar thickness and improves pulmonary hemodynamics. Finally, colchicine increases exercise capacity. Monocrotaline-induced PAH causes RV-specific derangement of microtubules marked by reduction in JPH2 and t-tubule disarray. Colchicine reduces microtubule density, increases JPH2 expression, and improves both t-tubule architecture and RV function. Colchicine also reduces adverse pulmonary vascular remodeling. These results provide biological plausibility for a clinical trial to repurpose colchicine as a RV-directed therapy for PAH

  13. The impact of the ketogenic diet on arterial morphology and endothelial function in children and young adults with epilepsy: a case-control study.

    Science.gov (United States)

    Coppola, Giangennaro; Natale, Francesco; Torino, Annarita; Capasso, Rosanna; D'Aniello, Alfredo; Pironti, Erica; Santoro, Elena; Calabrò, Raffaele; Verrotti, Alberto

    2014-04-01

    The present study aimed to assess the impact of the ketogenic diet on arterial morphology and endothelial function of the big vessels of the neck and on cardiac diastolic function, in a cohort of epileptic children and young adults treated with the ketogenic diet. Patients were recruited based on the following inclusion criteria: (1) patients who were or had been on the ketogenic diet for a time period of at least six months. Each patient underwent measurement of carotid intima media thickness, carotid artery stiffness, echocardiography, and diastolic function assessment. Patients with drug resistant epilepsy, matched for number, age and sex and never treated with ketogenic diet, were recruited as controls. The population study was composed by 43 epilepsy patients (23 males), aged between 19 months and 31 years (mean 11 years). Twenty-three patients were or had been treated with ketogenic diet, and 20 had never been on it (control group). Subjects treated with the ketogenic diet had higher arterial stiffness parameters, including AIx and β-index and higher serum levels of cholesterol or triglycerides compared to those who had never been on the diet (control group) (pketogenic diet, before the increase of the intima media thickness. This supports that arterial stiffness is an early marker of vascular damage. Copyright © 2013 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  14. Focused ultrasound-modulated glomerular ultrafiltration assessed by functional changes in renal arteries.

    Directory of Open Access Journals (Sweden)

    Feng-Yi Yang

    Full Text Available This study demonstrates the feasibility of using focused ultrasound (FUS to modulate glomerular ultrafiltration by renal artery sonication and determine if protein-creatinine ratios are estimated through vascular parameters. All animal experiments were approved by our Animal Care and Use Committee. The renal arteries of Sprague-Dawley rats were surgically exposed and sonicated at various acoustic power levels using a FUS transducer with a resonant frequency of 1 MHz. The mean peak systolic velocity (PSV of the blood flow was measured by Doppler ultrasound imaging. Urinary protein-creatinine ratios were calculated during the experiments. Histological examination of renal arteries and whole kidneys was performed. The PSV, pulsatility index, and resistance index of blood flow significantly increased in the arteries after FUS sonication without microbubbles (p<0.05. The change in normalized protein-creatinine ratios significantly increased with increasing acoustic power, but such was not observed when microbubbles were administered. Furthermore, no histological changes were observed in the hematoxylin- and eosin-stained sections. Glomerular ultrafiltration is regulated temporarily by renal artery sonication without microbubbles. Monitoring vascular parameters are useful in estimating the normalized change in protein-creatinine ratios.

  15. Origin and function of short-latency inputs to the neural substrates underlying the acoustic startle reflex

    Directory of Open Access Journals (Sweden)

    Ricardo eGómez-Nieto

    2014-07-01

    Full Text Available The acoustic startle reflex (ASR is a survival mechanism of alarm, which rapidly alerts the organism to a sudden loud auditory stimulus. In rats, the primary ASR circuit encompasses three serially connected structures: cochlear root neurons (CRNs, neurons in the caudal pontine reticular nucleus (PnC, and motoneurons in the medulla and spinal cord. It is well established that both CRNs and PnC neurons receive short-latency auditory inputs to mediate the ASR. Here, we investigated the anatomical origin and functional role of these inputs using a multidisciplinary approach that combines morphological, electrophysiological and behavioural techniques. Anterograde tracer injections into the cochlea suggest that CRNs somata and dendrites receive inputs depending, respectively, on their basal or apical cochlear origin. Confocal colocalization experiments demonstrated that these cochlear inputs are immunopositive for the vesicular glutamate transporter 1. Using extracellular recordings in vivo followed by subsequent tracer injections, we investigated the response of PnC neurons after contra-, ipsi-, and bilateral acoustic stimulation and identified the source of their auditory afferents. Our results showed that the binaural firing rate of PnC neurons was higher than the monaural, exhibiting higher spike discharges with contralateral than ipsilateral acoustic stimulations. Our histological analysis confirmed the CRNs as the principal source of short-latency acoustic inputs, and indicated that other areas of the cochlear nucleus complex are not likely to innervate PnC. Behaviourally, we observed a strong reduction of ASR amplitude in monaural earplugged rats that corresponds with the binaural summation process shown in our electrophysiological findings. Our study contributes to understand better the role of neuronal mechanisms in auditory alerting behaviours and provides strong evidence that the CRNs-PnC pathway mediates fast neurotransmission and binaural

  16. Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft.

    Science.gov (United States)

    Guizilini, Solange; Bolzan, Douglas W; Faresin, Sonia M; Ferraz, Raquel F; Tavolaro, Kelly; Cancio, Andrea A; Gomes, Walter J

    2012-01-25

    Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG). Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. The aim of this study was to compare the pulmonary function parameters, clinical outcomes, and pain score between patients undergoing pleurotomy with pleural drain placed in the subxyphoid position and patients with intact pleural cavity after off-pump CABG (OPCAB) using left internal thoracic artery (LITA). Seventy-one patients were allocated into two groups: I (n = 38 open left pleural cavity and pleural drain inserted in the subxyphoid position); II (n = 33 intact pleural cavity). Pulmonary function tests and clinical parameters were recorded preoperatively and on postoperative days (POD) 1, 3 and 5. Arterial blood gas analysis and shunt fraction were evaluated preoperatively and in POD1. Pain score was assessed on POD1. To monitor pleural effusion and atelectasis chest radiography was performed routinely 1 day before operation and until POD5. In both groups a significant impairment was found in lung function parameters until on POD5. However, no significant difference in forced vital capacity and forced expiratory volume in 1 second were seen between groups. A significant decrease in partial pressure of arterial oxygen and an increase in shunt fraction values were observed on POD1 in both groups, but no statistical difference was found when the groups were compared. Pleural effusion and atelectasis until on POD5 were similar in both groups. There were no statistical differences in pain score, duration of mechanical ventilation and postoperative hospital stay between groups. Subxyphoid insertion of pleural drain provides similar effects to

  17. Heart transplantation and arterial elasticity

    Directory of Open Access Journals (Sweden)

    Colvin-Adams M

    2013-12-01

    Full Text Available Monica Colvin-Adams,1 Nonyelum Harcourt,1 Robert LeDuc,2 Ganesh Raveendran,1 Yassir Sonbol,3 Robert Wilson,1 Daniel Duprez11Cardiovascular Division, University of Minnesota, Minneapolis, MN, USA; 2Division of Biostatistics University of Minnesota, Minneapolis, MN, USA; 3Cardiovascular Division, St Luke's Hospital System, Sugar Land, TX, USAObjective: Arterial elasticity is a functional biomarker that has predictive value for cardiovascular morbidity and mortality in nontransplant populations. There is little information regarding arterial elasticity in heart transplant recipients. This study aimed to characterize small (SAE and large (LAE artery elasticity in heart transplant recipients in comparison with an asymptomatic population free of overt cardiovascular disease. A second goal was to identify demographic and clinical factors associated with arterial elasticity in this unique population.Methods: Arterial pulse waveform was registered noninvasively at the radial artery in 71 heart transplant recipients between 2008 and 2010. SAEs and LAEs were derived from diastolic pulse contour analysis. Comparisons were made to a healthy cohort of 1,808 participants selected from our prevention clinic database. Multiple regression analyses were performed to evaluate associations between risk factors and SAE and LAE within the heart transplant recipients.Results: LAE and SAE were significantly lower in heart transplant recipients than in the normal cohort (P <0.01 and P < 0.0001, respectively. Female sex and history of ischemic cardiomyopathy were significantly associated with reduced LAE and SAE. Older age and the presence of moderate cardiac allograft vasculopathy were also significantly associated with reduced SAE. Transplant duration was associated with increased SAE.Conclusion: Heart transplants are associated with peripheral endothelial dysfunction and arterial stiffness, as demonstrated by a significant reduction in SAE and LAE when compared with a

  18. Hepatic artery aneurysm repair: a case report

    Directory of Open Access Journals (Sweden)

    Jaunoo SS

    2009-01-01

    Full Text Available Abstract Introduction Hepatic artery aneurysms remain a clinically significant entity. Their incidence continues to rise slowly and mortality from spontaneous rupture is high. Repair is recommended in those aneurysms greater than 2 cm in diameter. It is not surprising that vascular comorbidities, such as ischaemic heart disease, are common in surgical patients, particularly those with arterial aneurysms such as these. The decision of when to operate on patients who require urgent surgery despite having recently suffered an acute coronary syndrome remains somewhat of a grey and controversial area. We discuss the role of delayed surgery and postoperative followup of this vascular problem. Case presentation A 58-year-old man was admitted with a 5.5 cm hepatic artery aneurysm. The aneurysm was asymptomatic and was an incidental finding as a result of an abdominal computed tomography scan to investigate an episode of haemoptysis (Figure 1. Three weeks prior to admission, the patient had suffered a large inferior myocardial infarction and was treated by thrombolysis and primary coronary angioplasty. Angiographic assessment revealed a large aneurysm of the common hepatic artery involving the origins of the hepatic, gastroduodenal, left and right gastric arteries and the splenic artery (Figures 2 and 3. Endovascular treatment was not considered feasible and immediate surgery was too high-risk in the early post-infarction period. Therefore, surgery was delayed for 3 months when aneurysm repair with reconstruction of the hepatic artery was successfully performed. Graft patency was confirmed with the aid of an abdominal arterial duplex. Plasma levels of conventional liver function enzymes and of alpha-glutathione-S-transferase were within normal limits. This was used to assess the extent of any hepatocellular damage perioperatively. The patient made a good recovery and was well at his routine outpatient check-ups. Conclusion There is no significant

  19. Statistical identification of effective input variables

    International Nuclear Information System (INIS)

    Vaurio, J.K.

    1982-09-01

    A statistical sensitivity analysis procedure has been developed for ranking the input data of large computer codes in the order of sensitivity-importance. The method is economical for large codes with many input variables, since it uses a relatively small number of computer runs. No prior judgemental elimination of input variables is needed. The sceening method is based on stagewise correlation and extensive regression analysis of output values calculated with selected input value combinations. The regression process deals with multivariate nonlinear functions, and statistical tests are also available for identifying input variables that contribute to threshold effects, i.e., discontinuities in the output variables. A computer code SCREEN has been developed for implementing the screening techniques. The efficiency has been demonstrated by several examples and applied to a fast reactor safety analysis code (Venus-II). However, the methods and the coding are general and not limited to such applications

  20. The influence of contrast media on kidney function in patients with stable coronary artery disease

    DEFF Research Database (Denmark)

    Reuter, Simon Bertram; Harutyunyan, Marina; Mygind, Naja Dam

    2014-01-01

    AIMS: To investigate the incidence of contrast media-induced nephropathy (CIN) in patients with stable coronary artery disease (CAD) referred for elective coronary intervention following hydration routines. The reversibility of CIN was followed in a 6 month-period. METHODS AND RESULTS: A total...... coronary interventions. Kidney function and the amount of contrast media used was not a predictor of CIN development. The induced CIN was not completely normalized in a 6-month follow-up period....

  1. Smart mobility solution with multiple input Output interface.

    Science.gov (United States)

    Sethi, Aartika; Deb, Sujay; Ranjan, Prabhat; Sardar, Arghya

    2017-07-01

    Smart wheelchairs are commonly used to provide solution for mobility impairment. However their usage is limited primarily due to high cost owing from sensors required for giving input, lack of adaptability for different categories of input and limited functionality. In this paper we propose a smart mobility solution using smartphone with inbuilt sensors (accelerometer, camera and speaker) as an input interface. An Emotiv EPOC+ is also used for motor imagery based input control synced with facial expressions in cases of extreme disability. Apart from traction, additional functions like home security and automation are provided using Internet of Things (IoT) and web interfaces. Although preliminary, our results suggest that this system can be used as an integrated and efficient solution for people suffering from mobility impairment. The results also indicate a decent accuracy is obtained for the overall system.

  2. [Vascular aging, arterial hypertension and physical activity].

    Science.gov (United States)

    Schmidt-Trucksäss, A; Weisser, B

    2011-11-01

    The present review delineates the significance of intima-media-thickness, arterial stiffness and endothelial function for vascular aging. There is profound evidence for an increase in intima-media-thickness and vascular stiffness not only during healthy aging but induced also by cardiovascular risk factors. There is a central role of arterial hypertension for this progression in both structural factors. In addition, both parameters are strongly associated with cardiovascular risk. Endothelial function measured as postischemic flow-mediated vasodilatation is a functional parameter which is decreased both in healthy aging and by cardiovascular risk factors. Physical activity modifies the influence of aging and risk factors on endothelial function. A positive influence of endurance exercise on vascular stiffness and endothelial function has been demonstrated in numerous studies. In long-term studies, regular physical activity has been shown to reduce the progression of intima-media-thickness. Thus, arterial hypertension accelerates vascular aging, while physical activity has a positive influence on a variety of vascular parameters associated with vascular aging. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Short-Term Memory in Mathematics-Proficient and Mathematics-Disabled Students as a Function of Input-Modality/Output-Modality Pairings.

    Science.gov (United States)

    Webster, Raymond E.

    1980-01-01

    A significant two-way input modality by output modality interaction suggested that short term memory capacity among the groups differed as a function of the modality used to present the items in combination with the output response required. (Author/CL)

  4. Unraveling the relationship between arterial flow and intra-aneurysmal hemodynamics.

    Science.gov (United States)

    Morales, Hernán G; Bonnefous, Odile

    2015-02-26

    Arterial flow rate affects intra-aneurysmal hemodynamics but it is not clear how their relationship is. This uncertainty hinders the comparison among studies, including clinical evaluations, like a pre- and post-treatment status, since arterial flow rates may differ at each time acquisition. The purposes of this work are as follows: (1) To study how intra-aneurysmal hemodynamics changes within the full physiological range of arterial flow rates. (2) To provide characteristic curves of intra-aneurysmal velocity, wall shear stress (WSS) and pressure as functions of the arterial flow rate. Fifteen image-based aneurysm models were studied using computational fluid dynamics (CFD) simulations. The full range of physiological arterial flow rates reported in the literature was covered by 11 pulsatile simulations. For each aneurysm, the spatiotemporal-averaged blood flow velocity, WSS and pressure were calculated. Spatiotemporal-averaged velocity inside the aneurysm linearly increases as a function of the mean arterial flow (minimum R(2)>0.963). Spatiotemporal-averaged WSS and pressure at the aneurysm wall can be represented by quadratic functions of the arterial flow rate (minimum R(2)>0.996). Quantitative characterizations of spatiotemporal-averaged velocity, WSS and pressure inside cerebral aneurysms can be obtained with respect to the arterial flow rate. These characteristic curves provide more information of the relationship between arterial flow and aneurysm hemodynamics since the full range of arterial flow rates is considered. Having these curves, it is possible to compare experimental studies and clinical evaluations when different flow conditions are used. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Uterine arterial embolization to treat uterine leiomyoma

    International Nuclear Information System (INIS)

    Wang Huali; Han Lu; Wang Feng

    2002-01-01

    Objective: To assess the clinical effects of uterine arterial embolization on uterine leiomyoma. Methods: The authors treated 21 patients with uterine leiomyoma by Seldinger's uterine arterial embolization. The 4.0 F Cobra catheter was laced into the double uterine arteries with Polyvinyl Alcohol Foam (PVA) particles as the embolization. At 3 and 6 months postoperatively, the authors investigated the effects of the embolization. Results: After uterine arterial embolization, the volume of uterine leiomyoma decreased and menorrhagia was under controlled. The symptoms of anemia and oppression were relieved. The physiologic functions of ovary and uterus were preserved completely. Conclusions: Uterine arterial embolization is an effective and less invasive way to treat uterine leiomyoma

  6. Effects of dark chocolate and cocoa consumption on endothelial function and arterial stiffness in overweight adults.

    Science.gov (United States)

    West, Sheila G; McIntyre, Molly D; Piotrowski, Matthew J; Poupin, Nathalie; Miller, Debra L; Preston, Amy G; Wagner, Paul; Groves, Lisa F; Skulas-Ray, Ann C

    2014-02-01

    The consumption of cocoa and dark chocolate is associated with a lower risk of CVD, and improvements in endothelial function may mediate this relationship. Less is known about the effects of cocoa/chocolate on the augmentation index (AI), a measure of vascular stiffness and vascular tone in the peripheral arterioles. We enrolled thirty middle-aged, overweight adults in a randomised, placebo-controlled, 4-week, cross-over study. During the active treatment (cocoa) period, the participants consumed 37 g/d of dark chocolate and a sugar-free cocoa beverage (total cocoa = 22 g/d, total flavanols (TF) = 814 mg/d). Colour-matched controls included a low-flavanol chocolate bar and a cocoa-free beverage with no added sugar (TF = 3 mg/d). Treatments were matched for total fat, saturated fat, carbohydrates and protein. The cocoa treatment significantly increased the basal diameter and peak diameter of the brachial artery by 6% (+2 mm) and basal blood flow volume by 22%. Substantial decreases in the AI, a measure of arterial stiffness, were observed in only women. Flow-mediated dilation and the reactive hyperaemia index remained unchanged. The consumption of cocoa had no effect on fasting blood measures, while the control treatment increased fasting insulin concentration and insulin resistance (P= 0·01). Fasting blood pressure (BP) remained unchanged, although the acute consumption of cocoa increased resting BP by 4 mmHg. In summary, the high-flavanol cocoa and dark chocolate treatment was associated with enhanced vasodilation in both conduit and resistance arteries and was accompanied by significant reductions in arterial stiffness in women.

  7. TRPV1 channels in human skeletal muscle feed arteries: implications for vascular function.

    Science.gov (United States)

    Ives, Stephen J; Park, Song Young; Kwon, Oh Sung; Gifford, Jayson R; Andtbacka, Robert H I; Hyngstrom, John R; Richardson, Russell S

    2017-09-01

    What is the central question of this study? We sought to determine whether human skeletal muscle feed arteries (SFMAs) express TRPV 1 channels and what role they play in modulating vascular function. What is the main finding and its importance? Human SMFAs do express functional TRPV 1 channels that modulate vascular function, specifically opposing α-adrenergic receptor-mediated vasocontraction and potentiating vasorelaxation, in an endothelium-dependent manner, as evidenced by the α 1 -receptor-mediated responses. Thus, the vasodilatory role of TRPV 1 channels, and their ligand capsaicin, could be a potential therapeutic target for improving vascular function. Additionally, given the 'sympatholytic' effect of TRPV 1 activation and known endogenous activators (anandamide, reactive oxygen species, H + , etc.), TRPV 1 channels might contribute to functional sympatholysis during exercise. To examine the role of the transient receptor potential vanilloid type 1 (TRPV 1 ) ion channel in the vascular function of human skeletal muscle feed arteries (SMFAs) and whether activation of this heat-sensitive receptor could be involved in modulating vascular function, SMFAs from 16 humans (63 ± 5 years old, range 41-89 years) were studied using wire myography with capsaicin (TRPV 1 agonist) and without (control). Specifically, phenylephrine (α 1 -adrenergic receptor agonist), dexmedetomidine (α 2 -adrenergic receptor agonist), ACh and sodium nitroprusside concentration-response curves were established to assess the role of TRPV 1 channels in α-receptor-mediated vasocontraction as well as endothelium-dependent and -independent vasorelaxation, respectively. Compared with control conditions, capsaicin significantly attenuated maximal vasocontraction in response to phenylephrine [control, 52 ± 8% length-tension max (LT max ) and capsaicin, 21 ± 5%LT max ] and dexmedetomidine (control, 29 ± 12%LT max and capsaicin, 2 ± 3%LT max ), while robustly enhancing maximal

  8. Carotid Artery Intima-Media Thickness and Cutaneous Microvascular Function are Associated With Vitamin C Levels in Young Patients With Type 1 Diabetes

    DEFF Research Database (Denmark)

    Odermarsky, Michal; Lykkesfeldt, Jens; Liuba, Petru

    2008-01-01

    Background: Vascular endothelial dysfunction and accelerated thickening of arterial intima contribute to increased cardiovascular morbidity in type 1 diabetes. Although vitamin C has important antioxidant functions, and increased oxidative stress is a central mechanism of vascular abnormalities......, lower plasma levels of vitamin C appears to predispose to more pronounced adverse changes in both microcirculation and peripheral arteries. Further studies are needed to investigate whether dietary supplementation with vitamin C could retard the development of microvasculopathy and atherosclerosis...... in diabetes, the relationship between these two in young patients with this disease has not been yet investigated. Methods: Carotid artery intima-media thickness (cIMT) and cutaneous microvascular reactivity to endothelium-dependent (acetylcholine, ACH) and independent (sodium nitroprusside, SNP) were...

  9. Arterial Ventricular Uncoupling with Age and Disease and Recoupling with Exercise

    Science.gov (United States)

    Chantler, Paul D

    2017-01-01

    The deterioration in arterial and cardiac function with aging impairs arterial ventricular coupling, an important determinant of cardiovascular performance. However, exercise training improves arterial ventricular coupling especially during exercise during the age and disease process. This review examines the concept of arterial-ventricular coupling, and how age, and disease uncouples but exercise training recouples the heart and arterial system. PMID:28072585

  10. Dark chocolate and vascular function in patients with peripheral artery disease: a randomized, controlled cross-over trial.

    Science.gov (United States)

    Hammer, Alexandra; Koppensteiner, Renate; Steiner, Sabine; Niessner, Alexander; Goliasch, Georg; Gschwandtner, Michael; Hoke, Matthias

    2015-01-01

    Flavonoid-rich dark chocolate has positive effects on vascular function in healthy subjects and in patients at risk of atherosclerosis. The impact of dark chocolate on endothelial and microvascular function in patients with symptomatic peripheral artery disease (PAD) has not been investigated so far. In an investigator blinded, randomized, controlled, cross-over trial we assessed the effect of flavonoid-rich dark chocolate and cocoa-free control chocolate on flow-mediated dilatation (FMD) of the brachial artery and on microvascular function (assessed by Laser Doppler fluxmetry) in 21 patients with symptomatic (Fontaine stage II) PAD. Measurements were done in each patient on 2 single days, with an interval of 7 days, at baseline and at 2 hours after ingestion of 50 g dark chocolate or 50 g white chocolate, respectively. FMD remained unchanged after intake of dark chocolate (baseline and 2 hours after ingestion, %: 5.1 [IQR 4.4 to 7.3] and 5.5 [IQR 3.9 to 10.4]; p = 0.57, and after intake of white chocolate (baseline and 2 hours after ingestion, %: 6.4 [IQR 4.5 to 11.4] and 4.4 [IQR 2.6 to 8.7]; p = 0.14. Similarly, microcirculatory parameters were not significantly altered after intake of any chocolate compared with the respective baseline values. In conclusion, a single consumption of 50 g dark chocolate has no effect on endothelial and microvascular function in patients with symptomatic PAD.

  11. Relation between respiratory function and arterial stiffness assessed using brachial-ankle pulse wave velocity in healthy workers.

    Science.gov (United States)

    Inomoto, Atsushi; Fukuda, Rika; Deguchi, Junko; Toyonaga, Toshihiro

    2017-09-01

    [Purpose] Current studies report that patients with chronic obstructive pulmonary disease (COPD) may also have arteriosclerosis. This study aimed to investigate the relationship between respiratory function and arterial stiffness in healthy workers using the brachial-ankle pulse wave velocity (baPWV). [Subjects and Methods] This study included 104 male Japanese workers without COPD. We collected participant information and measured hemodynamics, body composition, and respiratory function. [Results] In the correlation analysis, baPWV showed a significant positive correlation with age, smoking index, systolic blood pressure, diastolic blood pressure, and heart rate, and a significant negative correlation with height, fat free mass, lower limb muscle mass, forced vital capacity (FVC), and forced expiratory volume in one second (FEV1). In multiple regression analysis using factors other than baPWV and respiratory function as adjustment variables, both FVC and FEV1 showed a significant negative relationship with baPWV (p=0.009 and p=0.027, respectively). FEV1/FVC was not significantly related to baPWV (p=0.704). [Conclusion] The results of this study indicated that FEV1/FVC and the proportion of FEV1 predicted, which are indicators of airflow limitation, are not predictors of baPWV in workers without airflow limitation. However, since baPWV showed a significant negative relationship with FVC and FEV 1, the reduction in respiratory function that does not cause airflow limitation, such as FVC or FEV1 decline, may be related to an increase in the risk of arterial stiffness.

  12. Respiratory muscle stretch gymnastics in patients with post coronary artery bypass grafting pain : Impact on respiratory muscle function, activity, mood and exercise capacity

    OpenAIRE

    會田, 信子; 渋谷, 優子; 吉野, 克樹; Komoda, Masaji; 井上, 智子

    2002-01-01

    A new rehabilitation (New-RH) program including respiratory muscle stretch gymnastics (RMSG) was developed to alleviate post-coronary artery bypass grafting pain (PCP). Effects on respiratory muscle function, pain, activities of daily living (ADL), mood and exercise capacity were investigated. Subjects were 16 consecutive patients undergoing median full sternotomy coronary artery bypass grafting (CABG), and were randomly divided into equal New-RH (S-group) and conventional therapy (C-group) g...

  13. Functional real-time optoacoustic imaging of middle cerebral artery occlusion in mice.

    Directory of Open Access Journals (Sweden)

    Moritz Kneipp

    Full Text Available BACKGROUND AND PURPOSE: Longitudinal functional imaging studies of stroke are key in identifying the disease progression and possible therapeutic interventions. Here we investigate the applicability of real-time functional optoacoustic imaging for monitoring of stroke progression in the whole brain of living animals. MATERIALS AND METHODS: The middle cerebral artery occlusion (MCAO was used to model stroke in mice, which were imaged preoperatively and the occlusion was kept in place for 60 minutes, after which optoacoustic scans were taken at several time points. RESULTS: Post ischemia an asymmetry of deoxygenated hemoglobin in the brain was observed as a region of hypoxia in the hemisphere affected by the ischemic event. Furthermore, we were able to visualize the penumbra in-vivo as a localized hemodynamically-compromised area adjacent to the region of stroke-induced perfusion deficit. CONCLUSION: The intrinsic sensitivity of the new imaging approach to functional blood parameters, in combination with real time operation and high spatial resolution in deep living tissues, may see it become a valuable and unique tool in the development and monitoring of treatments aimed at suspending the spread of an infarct area.

  14. Kinetic analysis of [11C]befloxatone in the human brain, a selective radioligand to image monoamine oxidase A.

    Science.gov (United States)

    Zanotti-Fregonara, Paolo; Leroy, Claire; Roumenov, Dimitri; Trichard, Christian; Martinot, Jean-Luc; Bottlaender, Michel

    2013-11-25

    [11C]Befloxatone measures the density of the enzyme monoamine oxidase A (MAO-A) in the brain. MAO-A is responsible for the degradation of different neurotransmitters and is implicated in several neurologic and psychiatric illnesses. This study sought to estimate the distribution volume (VT) values of [11C]befloxatone in humans using an arterial input function. Seven healthy volunteers were imaged with positron emission tomography (PET) after [11C]befloxatone injection. Kinetic analysis was performed using an arterial input function in association with compartmental modeling and with the Logan plot, multilinear analysis (MA1), and standard spectral analysis (SA) at both the regional and voxel level. Arterialized venous samples were drawn as an alternative and less invasive input function. An unconstrained two-compartment model reliably quantified VT values in large brain regions. A constrained model did not significantly improve VT identifiability. Similar VT results were obtained using SA; however, the Logan plot and MA1 slightly underestimated VT values (about -10%). At the voxel level, SA showed a very small bias (+2%) compared to compartmental modeling, Logan severely underestimated VT values, and voxel-wise images obtained with MA1 were too noisy to be reliably quantified. Arterialized venous blood samples did not provide a satisfactory alternative input function as the Logan-VT regional values were not comparable to those obtained with arterial sampling in all subjects. Binding of [11C]befloxatone to MAO-A can be quantified using an arterial input function and a two-compartment model or, in parametric images, with SA.

  15. On the Nature of the Input in Optimality Theory

    DEFF Research Database (Denmark)

    Heck, Fabian; Müller, Gereon; Vogel, Ralf

    2002-01-01

    The input has two main functions in optimality theory (Prince and Smolensky 1993). First, the input defines the candidate set, in other words it determines which output candidates compete for optimality, and which do not. Second, the input is referred to by faithfulness constraints that prohibit...... output candidates from deviating from specifications in the input. Whereas there is general agreement concerning the relevance of the input in phonology, the nature of the input in syntax is notoriously unclear. In this article, we show that the input should not be taken to define syntactic candidate...... and syntax is due to a basic, irreducible difference between these two components of grammar: Syntax is an information preserving system, phonology is not....

  16. Measuring Input Thresholds on an Existing Board

    Science.gov (United States)

    Kuperman, Igor; Gutrich, Daniel G.; Berkun, Andrew C.

    2011-01-01

    A critical PECL (positive emitter-coupled logic) interface to Xilinx interface needed to be changed on an existing flight board. The new Xilinx input interface used a CMOS (complementary metal-oxide semiconductor) type of input, and the driver could meet its thresholds typically, but not in worst-case, according to the data sheet. The previous interface had been based on comparison with an external reference, but the CMOS input is based on comparison with an internal divider from the power supply. A way to measure what the exact input threshold was for this device for 64 inputs on a flight board was needed. The measurement technique allowed an accurate measurement of the voltage required to switch a Xilinx input from high to low for each of the 64 lines, while only probing two of them. Directly driving an external voltage was considered too risky, and tests done on any other unit could not be used to qualify the flight board. The two lines directly probed gave an absolute voltage threshold calibration, while data collected on the remaining 62 lines without probing gave relative measurements that could be used to identify any outliers. The PECL interface was forced to a long-period square wave by driving a saturated square wave into the ADC (analog to digital converter). The active pull-down circuit was turned off, causing each line to rise rapidly and fall slowly according to the input s weak pull-down circuitry. The fall time shows up as a change in the pulse width of the signal ready by the Xilinx. This change in pulse width is a function of capacitance, pulldown current, and input threshold. Capacitance was known from the different trace lengths, plus a gate input capacitance, which is the same for all inputs. The pull-down current is the same for all inputs including the two that are probed directly. The data was combined, and the Excel solver tool was used to find input thresholds for the 62 lines. This was repeated over different supply voltages and

  17. The functional upregulation of piriform cortex is associated with cross-modal plasticity in loss of whisker tactile inputs.

    Directory of Open Access Journals (Sweden)

    Bing Ye

    Full Text Available Cross-modal plasticity is characterized as the hypersensitivity of remaining modalities after a sensory function is lost in rodents, which ensures their awareness to environmental changes. Cellular and molecular mechanisms underlying cross-modal sensory plasticity remain unclear. We aim to study the role of different types of neurons in cross-modal plasticity.In addition to behavioral tasks in mice, whole-cell recordings at the excitatory and inhibitory neurons, and their two-photon imaging, were conducted in piriform cortex. We produced a mouse model of cross-modal sensory plasticity that olfactory function was upregulated by trimming whiskers to deprive their sensory inputs. In the meantime of olfactory hypersensitivity, pyramidal neurons and excitatory synapses were functionally upregulated, as well as GABAergic cells and inhibitory synapses were downregulated in piriform cortex from the mice of cross-modal sensory plasticity, compared with controls. A crosswire connection between barrel cortex and piriform cortex was established in cross-modal plasticity.An upregulation of pyramidal neurons and a downregulation of GABAergic neurons strengthen the activities of neuronal networks in piriform cortex, which may be responsible for olfactory hypersensitivity after a loss of whisker tactile input. This finding provides the clues for developing therapeutic strategies to promote sensory recovery and substitution.

  18. Trigeminal, Visceral and Vestibular Inputs May Improve Cognitive Functions by Acting through the Locus Coeruleus and the Ascending Reticular Activating System: A New Hypothesis

    Directory of Open Access Journals (Sweden)

    Vincenzo De Cicco

    2018-01-01

    Full Text Available It is known that sensory signals sustain the background discharge of the ascending reticular activating system (ARAS which includes the noradrenergic locus coeruleus (LC neurons and controls the level of attention and alertness. Moreover, LC neurons influence brain metabolic activity, gene expression and brain inflammatory processes. As a consequence of the sensory control of ARAS/LC, stimulation of a sensory channel may potential influence neuronal activity and trophic state all over the brain, supporting cognitive functions and exerting a neuroprotective action. On the other hand, an imbalance of the same input on the two sides may lead to an asymmetric hemispheric excitability, leading to an impairment in cognitive functions. Among the inputs that may drive LC neurons and ARAS, those arising from the trigeminal region, from visceral organs and, possibly, from the vestibular system seem to be particularly relevant in regulating their activity. The trigeminal, visceral and vestibular control of ARAS/LC activity may explain why these input signals: (1 affect sensorimotor and cognitive functions which are not directly related to their specific informational content; and (2 are effective in relieving the symptoms of some brain pathologies, thus prompting peripheral activation of these input systems as a complementary approach for the treatment of cognitive impairments and neurodegenerative disorders.

  19. ESTIMATION OF COB-DOUGLAS AND TRANSLOG PRODUCTION FUNCTIONS WITH CAPITAL AND GENDER DISAGGREGATED LABOR INPUTS IN THE USA

    Directory of Open Access Journals (Sweden)

    Gertrude Sebunya Muwanga

    2018-01-01

    Full Text Available This is an empirical investigation of the homogeneity of gender disaggregated labor using the Douglas, single/multi-factor translog production functions; and labor productivity functions for the USA.   The results based on the single factor translog model, indicated that: an increase in the capita/female labor ratio increases aggregate output; male labor is more productive than female labor, which is more productive than capital; a simultaneous increase in quantity allocated and productivity of the leads to an increase in output; female labor productivity has grown slower than male labor productivity; it much easier to substitute male labor for capital compared to female labor; and the three inputs are neither perfect substitutes nor perfect complements. As a consequence, male and female labor are not homogenous inputs. Efforts to investigate the factors influencing gender disaggregated labor productivity; and designing policies to achieve gender parity in numbers/productivity in the labor force and increasing the ease of substitutability between male labor and female labor are required.

  20. Computer-assisted 3D reconstruction of the terminal branches of th cerebral arteries. Pt. 2. Middle cerebral artery

    International Nuclear Information System (INIS)

    Gloger, S.; Gloger, A.; Vogt, H.; Kretschmann, H.J.

    1994-01-01

    We present a three-dimensional anatomical computer model of the terminal branches of the middle cerebral artery, acquired from equidistant serial anatomical slices of three brains. The reconstructions provide a clear picture from all angles of the complicated course of the terminal branches of the cerebral arteries, which can help to identify them on conventional angiography and magnetic resonance angiography. The arteries can also be matched with CT, MR or PET images to indicate the areas of extension of individual branches, allowing neuromorphological and functional correlations. (orig.)

  1. Computer-assisted 3D reconstruction of the terminal branches of th cerebral arteries. Pt. 2. Middle cerebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Gloger, S. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Gloger, A. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Vogt, H. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Kretschmann, H.J. (Dept. of Neuroanatomy, Hannover Medical School (Germany))

    1994-04-01

    We present a three-dimensional anatomical computer model of the terminal branches of the middle cerebral artery, acquired from equidistant serial anatomical slices of three brains. The reconstructions provide a clear picture from all angles of the complicated course of the terminal branches of the cerebral arteries, which can help to identify them on conventional angiography and magnetic resonance angiography. The arteries can also be matched with CT, MR or PET images to indicate the areas of extension of individual branches, allowing neuromorphological and functional correlations. (orig.)

  2. Interventional therapy of atherosclerotic renal artery occlusion

    International Nuclear Information System (INIS)

    Li Jian; Xu Ke; Xiao Liang

    2009-01-01

    Objective: To investigate the effectiveness of interventional therapy for the atherosclerotic renal artery occlusion (ARAO). Methods: During the period of June 2001-Dec. 2007, 16 patients with ARAO (total of 16 occluded arteries) underwent interventional managements, including percutaneous endovascular renal artery revascularization, balloon dilatation angioplasty and stent placement. Follow-up survey was made at regular intervals. The patent condition of the renal artery was evaluated with ultrasonography and digital subtraction angiography. The blood pressure and the renal function were determined and the data were statistically analyzed in order to assess the intermediate and long-term effect of the interventional therapy. Results: Of 16 patients, technical success was achieved in 15 (93.8%) and failure occurred in one. During a follow-up period of 9 - 24 months, 3 patients died. According to the data obtained at each patient's last follow-up survey, the hypertension fell to normal in 3 (25.0%), was improved in 7 (58.3%) and showed no marked change in 2 patients (16.7%), with a clinical efficacy of 83.3% (10 / 12). The renal function was improved in 2 (16.7%), stabilized in 6 (50%) and deteriorated in 4 patients (33.3%), with an effective rate of 66.7% (8 / 12). Conclusion: For the treatment of atherosclerotic renal artery occlusion, the interventional therapy carries high successful rate and can effectively lower the blood pressure level, in addition, it can also protect the renal function in a certain degree. (authors)

  3. Left ventricular diastolic function in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Brugger, P.T.

    1986-01-01

    In 302 patients with confirmed coronary disease we determined the left ventricular diastolic function with the Nuclear Stethoscope by the aid of the Peak Filling Rate (PFR) and the Time to Peak Filling Rate (TPFR). Moreover we investigated the ejection fraction (EF). 201 patients had already suffered a myocardial infarction, of these 99 an anterior wall and 102 an inferior wall infarction. The remaining 101 patients had a CAD without a history of myocardial infarction. The PFR was 2.19 ± 0.65 EDV/sec in the 99 patients after anterior wall infarction and 2.62 ± 0.85 EDV/sec in the 102 patients after inferior wall infarction and 2.79 ± 0.85 EDV/sec in 101 patients with coronary artery disease without a history of myocardial infarction. For the PFR there could be found a statistically significant difference between normal patients and patients after anterior wall infarction (p [de

  4. Measurement of brachial artery endothelial function using a standard blood pressure cuff

    International Nuclear Information System (INIS)

    Maltz, Jonathan S; Budinger, Thomas F; Tison, Geoffrey H; Olgin, Jeffrey; Alley, Hugh F; Owens, Christopher D

    2015-01-01

    The integrity of endothelial function in major arteries (EFMA) is a powerful independent predictor of heart attack and stroke. Existing ultrasound-based non-invasive assessment methods are technically challenging and suitable only for laboratory settings. EFMA, like blood pressure (BP), is both acutely and chronically affected by factors such as lifestyle and medication. Consequently, laboratory-based measurements cannot fully gauge the effects of medical interventions on EFMA. EFMA and BP have, arguably, comparable (but complementary) value in the assessment of cardiovascular health. Widespread deployment of EFMA assessment is thus a desirable clinical goal. To this end, we propose a device based on modifying the measurement protocol of a standard electronic sphygmomanometer. The protocol involves inflating the cuff to sub-diastolic levels to enable recording of the pulse waveform before and after vasodilatory stimulus. The mechanical unloading of the arterial wall provided by the cuff amplifies the distension that occurs with each pulse, which is measured as a pressure variation in the cuff. We show that the height of the rising edge of each pulse is proportional to the change in lumen area between diastole and systole. This allows the effect of vasodilatory stimuli on the artery to be measured with high sensitivity. We compare the proposed cuff flow-mediated dilation (cFMD) method to ultrasound flow-mediated dilation (uFMD). We find significant correlation (r  =  0.55, p  =0.003, N  =  27) between cFMD- and uFMD-based metrics obtained when the release of a 5 min cuff occlusion is employed to induce endothelial stimulus via reactive hyperemia. cFMD is approximately proportional to the square of uFMD, representing a typical increase in sensitivity to vasodilation of 300–600%. This study illustrates the potential for an individual to conveniently measure his/her EFMA by using a low-cost reprogrammed home sphygmomanometer. (paper)

  5. Randomized controlled trial to evaluate the effect of canola oil on blood vessel function in peripheral arterial disease: rationale and design of the Canola-PAD Study

    Directory of Open Access Journals (Sweden)

    Enns JE

    2014-10-01

    Full Text Available Jennifer E Enns,1,2 Peter Zahradka,1–3 Randolph P Guzman,4,5 Alanna Baldwin,1 Brendon Foot,1 Carla G Taylor1–31Canadian Centre for Agri-Food Research in Health and Medicine, St Boniface Research Centre, Winnipeg, Canada; 2Department of Physiology, University of Manitoba, Winnipeg, Manitoba, Canada; 3Department of Human Nutritional Sciences, University of Manitoba, Winnipeg, Manitoba, Canada; 4IH Asper Clinical Research Institute, St Boniface Hospital, Winnipeg, Canada; 5Section of Vascular Surgery, Department of Surgery, St Boniface Hospital, Winnipeg, CanadaBackground: Individuals with peripheral arterial disease (PAD are at high risk for cardiac events due to atherosclerosis. Dietary fatty acid composition has been shown to modulate blood vessel properties, but whether a diet enriched in conventional canola oil can improve clinical endpoints in PAD is not known.Purpose: To describe the rationale and design of a clinical trial testing the effect of canola oil consumption on vascular function and cardiovascular risk factors in an 8-week dietary intervention in individuals with PAD.Methods: The Canola-PAD Study was a single center, prospective, double-blind, randomized controlled trial in 50 patients over 40 years old with PAD. Participants were randomized into two groups and consumed food items containing either conventional canola oil (25 g/day or an oil mixture representing the Western diet (25 g/day for 8 weeks as part of their usual diet. The primary outcome was vascular function (ankle-brachial index, arterial stiffness, endothelial dysfunction, walking capacity, and cognitive function. Secondary measurements included anthropometrics, serum lipid profile and fatty acid composition, markers of inflammation and glycemic control, and serum metabolite profile.Discussion: The Canola-PAD Study uses an innovative and noninvasive approach to evaluate the effect of canola oil on clinically relevant outcomes in individuals with PAD, including

  6. Flexible and re-configurable optical three-input XOR logic gate of phase-modulated signals with multicast functionality for potential application in optical physical-layer network coding.

    Science.gov (United States)

    Lu, Guo-Wei; Qin, Jun; Wang, Hongxiang; Ji, XuYuefeng; Sharif, Gazi Mohammad; Yamaguchi, Shigeru

    2016-02-08

    Optical logic gate, especially exclusive-or (XOR) gate, plays important role in accomplishing photonic computing and various network functionalities in future optical networks. On the other hand, optical multicast is another indispensable functionality to efficiently deliver information in optical networks. In this paper, for the first time, we propose and experimentally demonstrate a flexible optical three-input XOR gate scheme for multiple input phase-modulated signals with a 1-to-2 multicast functionality for each XOR operation using four-wave mixing (FWM) effect in single piece of highly-nonlinear fiber (HNLF). Through FWM in HNLF, all of the possible XOR operations among input signals could be simultaneously realized by sharing a single piece of HNLF. By selecting the obtained XOR components using a followed wavelength selective component, the number of XOR gates and the participant light in XOR operations could be flexibly configured. The re-configurability of the proposed XOR gate and the function integration of the optical logic gate and multicast in single device offer the flexibility in network design and improve the network efficiency. We experimentally demonstrate flexible 3-input XOR gate for four 10-Gbaud binary phase-shift keying signals with a multicast scale of 2. Error-free operations for the obtained XOR results are achieved. Potential application of the integrated XOR and multicast function in network coding is also discussed.

  7. Self-Structured Organizing Single-Input CMAC Control for Robot Manipulator

    Directory of Open Access Journals (Sweden)

    ThanhQuyen Ngo

    2011-09-01

    Full Text Available This paper represents a self-structured organizing single-input control system based on differentiable cerebellar model articulation controller (CMAC for an n-link robot manipulator to achieve the high-precision position tracking. In the proposed scheme, the single-input CMAC controller is solely used to control the plant, so the input space dimension of CMAC can be simplified and no conventional controller is needed. The structure of single-input CMAC will also be self-organized; that is, the layers of single-input CMAC will grow or prune systematically and their receptive functions can be automatically adjusted. The online tuning laws of single-input CMAC parameters are derived in gradient-descent learning method and the discrete-type Lyapunov function is applied to determine the learning rates of proposed control system so that the stability of the system can be guaranteed. The simulation results of robot manipulator are provided to verify the effectiveness of the proposed control methodology.

  8. Left ventricular diastolic function in type 2 diabetes mellitus and the association with coronary artery calcium score: a cardiac MRI study.

    Science.gov (United States)

    Graça, Bruno; Donato, Paulo; Ferreira, Maria João; Castelo-Branco, Miguel; Caseiro-Alves, Filipe

    2014-06-01

    The purpose of this study was to compare cardiac MRI-derived parameters of left ventricular (LV) diastolic function between uncomplicated type 2 diabetes mellitus (DM2) and normoglycemic control subjects and to evaluate whether these parameters of LV diastolic function are related to coronary atherosclerosis. We prospectively studied 41 subjects with DM2 and 21 normoglycemic control subjects (30 women and 32 men; mean age, 57.2 ± 7.1 [SD] years) with no evidence of overt cardiovascular disease. We used cardiac MRI to measure LV volumes, LV peak filling rate (PFR), and transmitral flow and CT to determine coronary artery calcium scores. Absolute values of the peak filling rate (PFR) were significantly lower in DM2 patients than in control subjects (mean ± SD, 293.2 ± 51.7 vs 375.7 ± 102.8 mL/s, respectively; p DM2 patients compared with control subjects. DM2 patients with coronary artery calcification showed a lower PFR normalized to stroke volume (SV) (mean ± SD, 4.4 ± 1.0 vs 5.3 ± 1.4, respectively; p = 0.038) and lower mitral peak E velocities (40.1 ± 11.3 vs 48.0 ± 7.3 cm/s; p = 0.024) than DM2 patients without coronary calcification. PFR normalized to SV was independently associated with the presence of coronary artery calcification (β = -1.5, p = 0.005). DM2 decreases cardiovascular MRI-derived parameters of LV diastolic function. Patients with DM2 and coronary atherosclerosis show a more impaired LV diastolic function than patients without coronary atherosclerosis.

  9. Mechanical design in arteries.

    Science.gov (United States)

    Shadwick, R E

    1999-12-01

    The most important mechanical property of the artery wall is its non-linear elasticity. Over the last century, this has been well-documented in vessels in many animals, from humans to lobsters. Arteries must be distensible to provide capacitance and pulse-smoothing in the circulation, but they must also be stable to inflation over a range of pressure. These mechanical requirements are met by strain-dependent increases in the elastic modulus of the vascular wall, manifest by a J-shaped stress-strain curve, as typically exhibited by other soft biological tissues. All vertebrates and invertebrates with closed circulatory systems have arteries with this non-linear behaviour, but specific tissue properties vary to give correct function for the physiological pressure range of each species. In all cases, the non-linear elasticity is a product of the parallel arrangement of rubbery and stiff connective tissue elements in the artery wall, and differences in composition and tissue architecture can account for the observed variations in mechanical properties. This phenomenon is most pronounced in large whales, in which very high compliance in the aortic arch and exceptionally low compliance in the descending aorta occur, and is correlated with specific modifications in the arterial structure.

  10. Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft

    Directory of Open Access Journals (Sweden)

    Guizilini Solange

    2012-01-01

    Full Text Available Abstract Background Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG. Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. The aim of this study was to compare the pulmonary function parameters, clinical outcomes, and pain score between patients undergoing pleurotomy with pleural drain placed in the subxyphoid position and patients with intact pleural cavity after off-pump CABG (OPCAB using left internal thoracic artery (LITA. Methods Seventy-one patients were allocated into two groups: I (n = 38 open left pleural cavity and pleural drain inserted in the subxyphoid position; II (n = 33 intact pleural cavity. Pulmonary function tests and clinical parameters were recorded preoperatively and on postoperative days (POD 1, 3 and 5. Arterial blood gas analysis and shunt fraction were evaluated preoperatively and in POD1. Pain score was assessed on POD1. To monitor pleural effusion and atelectasis chest radiography was performed routinely 1 day before operation and until POD5. Results In both groups a significant impairment was found in lung function parameters until on POD5. However, no significant difference in forced vital capacity and forced expiratory volume in 1 second were seen between groups. A significant decrease in partial pressure of arterial oxygen and an increase in shunt fraction values were observed on POD1 in both groups, but no statistical difference was found when the groups were compared. Pleural effusion and atelectasis until on POD5 were similar in both groups. There were no statistical differences in pain score, duration of mechanical ventilation and postoperative hospital stay between groups. Conclusion Subxyphoid

  11. Interesting images: Multiple coronary artery aneurysms.

    Science.gov (United States)

    Howard, Jonathon M; Viswanath, Omar; Armas, Alfredo; Santana, Orlando; Rosen, Gerald P

    2017-01-01

    We present the case of a 65-year-old male who presented with stable angina and dyspnea on exertion. His initial workup yielded a positive treadmill stress test for reversible apical ischemia, and transthoracic echocardiogram demonstrated impaired systolic function. Cardiac catheterization was then performed, revealing severe atherosclerotic disease including multiple coronary artery aneurysms. As a result, the patient was advised to and subsequently underwent a coronary artery bypass graft. This case highlights the presence of multiple coronary artery aneurysms and the ability to appreciate these pathologic findings on multiple imaging modalities, including coronary angiogram, transesophageal echocardiography, and direct visualization through the surgical field.

  12. Differential anti-ischaemic effects of muscarinic receptor blockade in patients with obstructive coronary artery disease; impaired vs normal left ventricular function.

    NARCIS (Netherlands)

    A.F. van den Heuvel; D.J. van Veldhuisen (Dirk); G.L. Bartels; M. van der Ent (Martin); W.J. Remme (Willem)

    1999-01-01

    textabstractAIMS: In patients with coronary artery disease acetylcholine (a muscarinic agonist) causes vasoconstriction. The effect of atropine (a muscarinic antagonist) on coronary vasotone in patients with normal or impaired left ventricular function is unknown.

  13. Pathophysiological Features of Endogenous Intoxication in Pregnant Women with Arterial Hypertension

    Directory of Open Access Journals (Sweden)

    N. V. Kabanova

    2008-01-01

    Full Text Available Objective: to determine the nature and specific features of development of endogenous intoxication in pregnant women with arterial hypertension. Subjects and materials. Humoral extracellular fluid volume regulation, partial renal functions, placental hormonal function, membranous lipid peroxidation activity, antiradical defense, the parameters of central hemodynamics, endogenous intoxication, and a biochemical coagulogram were studied and differential blood count with the leukocytic ratio indices was estimated in 172 pregnant females with arterial hypertension and 54 healthy pregnant ones in the third trimester. The statistical package «Stadia» was applied. Results. Arterial hypertension caused by pregnancy was ascertained to involve pathogenetically different types: low-, normal-, and high-renin ones. In pregnant women with arterial hypertension, the general pathogenetic homeostatic changes were placental hormonal imbalance, activated membranous lipid peroxidation, impaired lymph outflow, sodium and water retention, hepatic and renal failure, and endogenous intoxication. Conclusion. Placental ischemia appearing as placental hormonal imbalance (extrarenal pressor system was accompanied by a compensatory humoral response: arterial hypertension and metabolic disturbances. Changes in medium-weight molecule 280, leukocytic intoxication index, erythrocytic sorption capacity, and Paramecium test, by confirming the presence of endogenous intoxication in pregnant females with arterial hypertension, were caused by a type of arterial hypertension (by the hemodynamic profile and the type of impaired partial renal functions. Key words: pregnancy, arterial hypertension, endogenous intoxication.

  14. A new diagnostic approach to popliteal artery entrapment syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Charles; Kennedy, Dominic; Bastian-Jordan, Matthew; Hislop, Matthew; Cramp, Brendan; Dhupelia, Sanjay [Queensland X-Ray, Sunnybank, Queensland, 4109 (Australia)

    2015-09-15

    A new method of diagnosing and defining functional popliteal artery entrapment syndrome is described. By combining ultrasonography and magnetic resonance imaging techniques with dynamic plantarflexion of the ankle against resistance, functional entrapment can be demonstrated and the location of the arterial occlusion identified. This combination of imaging modalities will also define muscular anatomy for guiding intervention such as surgery or Botox injection.

  15. A new diagnostic approach to popliteal artery entrapment syndrome

    International Nuclear Information System (INIS)

    Williams, Charles; Kennedy, Dominic; Bastian-Jordan, Matthew; Hislop, Matthew; Cramp, Brendan; Dhupelia, Sanjay

    2015-01-01

    A new method of diagnosing and defining functional popliteal artery entrapment syndrome is described. By combining ultrasonography and magnetic resonance imaging techniques with dynamic plantarflexion of the ankle against resistance, functional entrapment can be demonstrated and the location of the arterial occlusion identified. This combination of imaging modalities will also define muscular anatomy for guiding intervention such as surgery or Botox injection

  16. The Effect of Endovascular Revascularization of Common Iliac Artery Occlusions on Erectile Function

    International Nuclear Information System (INIS)

    Gur, Serkan; Ozkan, Uğur; Onder, Hakan; Tekbas, Güven; Oguzkurt, Levent

    2013-01-01

    To determine the incidence of erectile dysfunction in patients with common iliac artery (CIA) occlusive disease and the effect of revascularization on erectile function using the sexual health inventory for males (SHIM) questionnaire. All patients (35 men; mean age 57 ± 5 years; range 42–67 years) were asked to recall their sexual function before and 1 month after iliac recanalization. Univariate and multivariate analyses were performed to determine variables effecting improvement of impotence. The incidence of impotence in patients with CIA occlusion was 74% (26 of 35) preoperatively. Overall 16 (46%) of 35 patients reported improved erectile function after iliac recanalization. The rate of improvement of impotence was 61.5% (16 of 26 impotent patients). Sixteen patients (46%), including seven with normal erectile function before the procedure, had no change. Three patients (8%) reported deterioration of their sexual function, two of whom (6%) had normal erectile function before the procedure. The median SHIM score increased from 14 (range 4–25) before the procedure to 20 (range 1–25) after the procedure (P = 0.005). The type of recanalization, the age of the patients, and the length of occlusion were related to erectile function improvement in univariate analysis. However, these factors were not independent factors for improvement of erectile dysfunction in multivariate analysis (P > 0.05). Endovascular recanalization of CIA occlusions clearly improves sexual function. More than half of the patients with erectile dysfunction who underwent endovascular recanalization of the CIA experienced improvement.

  17. The Effect of Endovascular Revascularization of Common Iliac Artery Occlusions on Erectile Function

    Energy Technology Data Exchange (ETDEWEB)

    Gur, Serkan, E-mail: mserkangur@yahoo.com [Sifa Hospital, Department of Radiology (Turkey); Ozkan, Ugur [Baskent University, Department of Radiology, Faculty of Medicine (Turkey); Onder, Hakan; Tekbas, Gueven [Dicle University, Department of Radiology, Faculty of Medicine (Turkey); Oguzkurt, Levent [Baskent University, Department of Radiology, Faculty of Medicine (Turkey)

    2013-02-15

    To determine the incidence of erectile dysfunction in patients with common iliac artery (CIA) occlusive disease and the effect of revascularization on erectile function using the sexual health inventory for males (SHIM) questionnaire. All patients (35 men; mean age 57 {+-} 5 years; range 42-67 years) were asked to recall their sexual function before and 1 month after iliac recanalization. Univariate and multivariate analyses were performed to determine variables effecting improvement of impotence. The incidence of impotence in patients with CIA occlusion was 74% (26 of 35) preoperatively. Overall 16 (46%) of 35 patients reported improved erectile function after iliac recanalization. The rate of improvement of impotence was 61.5% (16 of 26 impotent patients). Sixteen patients (46%), including seven with normal erectile function before the procedure, had no change. Three patients (8%) reported deterioration of their sexual function, two of whom (6%) had normal erectile function before the procedure. The median SHIM score increased from 14 (range 4-25) before the procedure to 20 (range 1-25) after the procedure (P = 0.005). The type of recanalization, the age of the patients, and the length of occlusion were related to erectile function improvement in univariate analysis. However, these factors were not independent factors for improvement of erectile dysfunction in multivariate analysis (P > 0.05). Endovascular recanalization of CIA occlusions clearly improves sexual function. More than half of the patients with erectile dysfunction who underwent endovascular recanalization of the CIA experienced improvement.

  18. Six axis force feedback input device

    Science.gov (United States)

    Ohm, Timothy (Inventor)

    1998-01-01

    The present invention is a low friction, low inertia, six-axis force feedback input device comprising an arm with double-jointed, tendon-driven revolute joints, a decoupled tendon-driven wrist, and a base with encoders and motors. The input device functions as a master robot manipulator of a microsurgical teleoperated robot system including a slave robot manipulator coupled to an amplifier chassis, which is coupled to a control chassis, which is coupled to a workstation with a graphical user interface. The amplifier chassis is coupled to the motors of the master robot manipulator and the control chassis is coupled to the encoders of the master robot manipulator. A force feedback can be applied to the input device and can be generated from the slave robot to enable a user to operate the slave robot via the input device without physically viewing the slave robot. Also, the force feedback can be generated from the workstation to represent fictitious forces to constrain the input device's control of the slave robot to be within imaginary predetermined boundaries.

  19. Computer-assisted 3D reconstruction of the terminal branches of the cerebral arteries. Pt. 1. Anterior cerebral artery

    International Nuclear Information System (INIS)

    Gloger, S.; Gloger, A.; Vogt, H.; Kretschmann, H.J.

    1994-01-01

    We present a three-dimensional anatomical computer model of the terminal branches of the anterior cerebral artery, acquired from equidistant serial anatomical slices of three brains. The reconstructions provide a clear picture from all angles of the complicated course of the terminal branches of the cerebral arteries, which can help to identify them on conventional and magnetic resonance angiography. Our rendition of the cerebral arteries can also be matched with CT, MR or PET images to indicate the areas of extension of individual branches, allowing neuromorphological and functional correlation. (orig.)

  20. Computer-assisted 3D reconstruction of the terminal branches of the cerebral arteries. Pt. 1. Anterior cerebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Gloger, S. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Gloger, A. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Vogt, H. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Kretschmann, H.J. (Dept. of Neuroanatomy, Hannover Medical School (Germany))

    1994-04-01

    We present a three-dimensional anatomical computer model of the terminal branches of the anterior cerebral artery, acquired from equidistant serial anatomical slices of three brains. The reconstructions provide a clear picture from all angles of the complicated course of the terminal branches of the cerebral arteries, which can help to identify them on conventional and magnetic resonance angiography. Our rendition of the cerebral arteries can also be matched with CT, MR or PET images to indicate the areas of extension of individual branches, allowing neuromorphological and functional correlation. (orig.)

  1. GARFEM input deck description

    Energy Technology Data Exchange (ETDEWEB)

    Zdunek, A.; Soederberg, M. (Aeronautical Research Inst. of Sweden, Bromma (Sweden))

    1989-01-01

    The input card deck for the finite element program GARFEM version 3.2 is described in this manual. The program includes, but is not limited to, capabilities to handle the following problems: * Linear bar and beam element structures, * Geometrically non-linear problems (bar and beam), both static and transient dynamic analysis, * Transient response dynamics from a catalog of time varying external forcing function types or input function tables, * Eigenvalue solution (modes and frequencies), * Multi point constraints (MPC) for the modelling of mechanisms and e.g. rigid links. The MPC definition is used only in the geometrically linearized sense, * Beams with disjunct shear axis and neutral axis, * Beams with rigid offset. An interface exist that connects GARFEM with the program GAROS. GAROS is a program for aeroelastic analysis of rotating structures. Since this interface was developed GARFEM now serves as a preprocessor program in place of NASTRAN which was formerly used. Documentation of the methods applied in GARFEM exists but is so far limited to the capacities in existence before the GAROS interface was developed.

  2. The Impact of Carotid Artery Stenting on Cerebral Perfusion, Functional Connectivity, and Cognition in Severe Asymptomatic Carotid Stenosis Patients

    Directory of Open Access Journals (Sweden)

    Tao Wang

    2017-08-01

    Full Text Available Background and purposeAsymptomatic carotid artery stenosis can lead to not only stroke but also cognition impairment. Although it has been proven that carotid artery stenting (CAS can reduce the risk of future strokes, the effect of CAS on cognition is conflicting. In recent years, pulsed arterial spin labeling (pASL MRI and resting-state functional MRI (R-fMRI have been employed in cognitive impairment studies. For the present study, cognition is evaluated in severe asymptomatic carotid artery stenosis patients undergoing CAS, and the mechanisms underlying the cognitive change are explored by pASL MRI and R-fMRI.Materials and methodsWe prospectively enrolled 24 asymptomatic, severe (≥70%, unilateral internal carotid artery stenosis patients, who were expecting the intervention of CAS. Cognition assessment (including the Montreal Cognitive Assessment Beijing Version, the Minimum Mental State Examination, the Digit Symbol Test, the Rey Auditory Verbal Learning Test, and the Verbal Memory Test and an integrated MRI program (pASL MRI, and R-fMRI were administered 7 days before and 3 months after CAS.Results16 subjects completed the follow-up study. After stenting, significant improvement in the scores of the MMSE, the Verbal Memory test, and the delayed recall was found. No significant difference was found in the scores of the Montreal Cognitive Assessment Beijing Version, the Digit Symbol Test, and the immediate recall. After CAS treatment, asymptomatic carotid artery stenosis patients showed increased perfusion in the left frontal gyrus, increased amplitude of low-frequency fluctuation (ALFF in the right precentral gyrus, and increased connectivity to the posterior cingulate cortex (PCC in the right supra frontal gyrus. However, no significant correlations were found between these imaging changes and cognition assessments.ConclusionSuccessful CAS can partly improve cognition in asymptomatic carotid artery stenosis patients. The cognition

  3. Spatial differences of cellular origins and in vivo hypoxia modify contractile properties of pulmonary artery smooth muscle cells: lessons for arterial tissue engineering.

    Science.gov (United States)

    Hall, S M; Soueid, A; Smith, T; Brown, R A; Haworth, S G; Mudera, V

    2007-01-01

    Tissue engineering of functional arteries is challenging. Within the pulmonary artery wall, smooth muscle cells (PASMCs) have site-specific developmental and functional phenotypes, reflecting differing contractile roles. The force generated by PASMCs isolated from the inner 25% and outer 50% of the media of intrapulmonary elastic arteries from five normal and eight chronically hypoxic (hypertensive) 14 day-old piglets was quantified in a three-dimensional (3D) collagen construct, using a culture force monitor. Outer medial PASMCs from normal piglets exerted more force (528 +/- 50 dynes) than those of hypoxic piglets (177 +/- 42 dynes; p engineering of major blood vessels.

  4. Activity and function recognition for moving and static objects in urban environments from wide-area persistent surveillance inputs

    Science.gov (United States)

    Levchuk, Georgiy; Bobick, Aaron; Jones, Eric

    2010-04-01

    In this paper, we describe results from experimental analysis of a model designed to recognize activities and functions of moving and static objects from low-resolution wide-area video inputs. Our model is based on representing the activities and functions using three variables: (i) time; (ii) space; and (iii) structures. The activity and function recognition is achieved by imposing lexical, syntactic, and semantic constraints on the lower-level event sequences. In the reported research, we have evaluated the utility and sensitivity of several algorithms derived from natural language processing and pattern recognition domains. We achieved high recognition accuracy for a wide range of activity and function types in the experiments using Electro-Optical (EO) imagery collected by Wide Area Airborne Surveillance (WAAS) platform.

  5. Measurement of regional cerebral blood flow using one-point venous blood sampling and causality model. Evaluation by comparing with conventional continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Mimura, Hiroaki; Sone, Teruki; Takahashi, Yoshitake

    2008-01-01

    Optimal setting of the input function is essential for the measurement of regional cerebral blood flow (rCBF) based on the microsphere model using N-isopropyl-4-[ 123 I]iodoamphetamine ( 123 I-IMP), and usually the arterial 123 I-IMP concentration (integral value) in the initial 5 min is used for this purpose. We have developed a new convenient method in which 123 I-IMP concentration in arterial blood sample is estimated from that in venous blood sample. Brain perfusion single photon emission computed tomography (SPECT) with 123 I-IMP was performed in 110 cases of central nervous system disorders. The causality was analyzed between the various parameters of SPECT data and the ratio of octanol-extracted arterial radioactivity concentration during the first 5 min (Caoct) to octanol-extracted venous radioactivity concentration at 27 min after intravenous injection of 123 I-IMP (Cvoct). A high correlation was observed between the measured and estimated values of Caoct/Cvoct (r=0.856) when the following five parameters were included in the regression formula: radioactivity concentration in venous blood sampled at 27 min (Cv), Cvoct, Cvoct/Cv, and total brain radioactivity counts that were measured by a four-head gamma camera 5 min and 28 min after 123 I-IMP injection. Furthermore, the rCBF values obtained using the input parameters estimated by this method were also highly correlated with the rCBF values measured using the continuous arterial blood sampling method (r=0.912). These results suggest that this method would serve as the new, convenient and less invasive method of rCBF measurement in clinical setting. (author)

  6. Arterial stiffness and cognitive impairment.

    Science.gov (United States)

    Li, Xiaoxuan; Lyu, Peiyuan; Ren, Yanyan; An, Jin; Dong, Yanhong

    2017-09-15

    Arterial stiffness is one of the earliest indicators of changes in vascular wall structure and function and may be assessed using various indicators, such as pulse-wave velocity (PWV), the cardio-ankle vascular index (CAVI), the ankle-brachial index (ABI), pulse pressure (PP), the augmentation index (AI), flow-mediated dilation (FMD), carotid intima media thickness (IMT) and arterial stiffness index-β. Arterial stiffness is generally considered an independent predictor of cardiovascular and cerebrovascular diseases. To date, a significant number of studies have focused on the relationship between arterial stiffness and cognitive impairment. To investigate the relationships between specific arterial stiffness parameters and cognitive impairment, elucidate the pathophysiological mechanisms underlying the relationship between arterial stiffness and cognitive impairment and determine how to interfere with arterial stiffness to prevent cognitive impairment, we searched PUBMED for studies regarding the relationship between arterial stiffness and cognitive impairment that were published from 2000 to 2017. We used the following key words in our search: "arterial stiffness and cognitive impairment" and "arterial stiffness and cognitive impairment mechanism". Studies involving human subjects older than 30years were included in the review, while irrelevant studies (i.e., studies involving subjects with comorbid kidney disease, diabetes and cardiac disease) were excluded from the review. We determined that arterial stiffness severity was positively correlated with cognitive impairment. Of the markers used to assess arterial stiffness, a higher PWV, CAVI, AI, IMT and index-β and a lower ABI and FMD were related to cognitive impairment. However, the relationship between PP and cognitive impairment remained controversial. The potential mechanisms linking arterial stiffness and cognitive impairment may be associated with arterial pulsatility, as greater arterial pulsatility

  7. Input Shaping to Reduce Solar Array Structural Vibrations

    Science.gov (United States)

    Doherty, Michael J.; Tolson, Robert J.

    1998-01-01

    Structural vibrations induced by actuators can be minimized using input shaping. Input shaping is a feedforward method in which actuator commands are convolved with shaping functions to yield a shaped set of commands. These commands are designed to perform the maneuver while minimizing the residual structural vibration. In this report, input shaping is extended to stepper motor actuators. As a demonstration, an input-shaping technique based on pole-zero cancellation was used to modify the Solar Array Drive Assembly (SADA) actuator commands for the Lewis satellite. A series of impulses were calculated as the ideal SADA output for vibration control. These impulses were then discretized for use by the SADA stepper motor actuator and simulated actuator outputs were used to calculate the structural response. The effectiveness of input shaping is limited by the accuracy of the knowledge of the modal frequencies. Assuming perfect knowledge resulted in significant vibration reduction. Errors of 10% in the modal frequencies caused notably higher levels of vibration. Controller robustness was improved by incorporating additional zeros in the shaping function. The additional zeros did not require increased performance from the actuator. Despite the identification errors, the resulting feedforward controller reduced residual vibrations to the level of the exactly modeled input shaper and well below the baseline cases. These results could be easily applied to many other vibration-sensitive applications involving stepper motor actuators.

  8. Cardiac MRI in pulmonary artery hypertension: correlations between morphological and functional parameters and invasive measurements

    Energy Technology Data Exchange (ETDEWEB)

    Alunni, Jean-Philippe; Otal, Philippe; Rousseau, Herve; Chabbert, Valerie [CHU Rangueil, Department of Radiology, Toulouse (France); Degano, Bruno; Tetu, Laurent; Didier, Alain [CHU Larrey, Department of Pneumology, Toulouse (France); Arnaud, Catherine [CHU Rangueil, Department of Methods in Clinical Research, Toulouse (France); Blot-Souletie, Nathalie [CHU Rangueil, Department of Cardiology, Toulouse (France)

    2010-05-15

    To compare cardiac MRI with right heart catheterisation in patients with pulmonary hypertension (PH) and to evaluate its ability to assess PH severity. Forty patients were included. MRI included cine and phase-contrast sequences, study of ventricular function, cardiac cavity areas and ratios, position of the interventricular septum (IVS) in systole and diastole, and flow measurements. We defined four groups according to the severity of PH and three groups according to IVS position: A, normal position; B, abnormal in diastole; C, abnormal in diastole and systole. IVS position was correlated with pulmonary artery pressures and PVR (pulmonary vascular resistance). Median pulmonary artery pressures and resistance were significantly higher in patients with an abnormal septal position compared with those with a normal position. Correlations were good between the right ventricular ejection fraction and PVR, right ventricular end-systolic volume and PAP, percentage of right ventricular area change and PVR, and diastolic and systolic ventricular area ratio and PVR. These parameters were significantly associated with PH severity. Cardiac MRI can help to assess the severity of PH. (orig.)

  9. Effect of coronary artery recanalization on right ventricular function in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Verani, M.S.; Tortoledo, F.E.; Batty, J.W.; Raizner, A.E.

    1985-01-01

    The effects of coronary artery recanalization by intracoronary administration of streptokinase on left ventricular function during acute myocardial infarction have received increasing attention in recent years. Although myocardial dysfunction is often more pronounced in the right ventricle than in the left ventricle in patients with acute inferior wall myocardial infarction, the effect of coronary artery recanalization on right ventricular dysfunction has not been previously addressed. Accordingly, in this investigation, 54 patients who participated in a prospective, controlled, randomized trial of recanalization during acute myocardial infarction were studied. Among 30 patients with inferior wall infarction, 19 had right ventricular dysfunction on admission; 11 of these 19 had positive uptake of technetium-99m pyrophosphate in the right ventricle, indicative of right ventricular infarction. Patients with successful recanalization exhibited improved right ventricular ejection fraction from admission to day 10. However, control patients and patients who did not undergo recanalization also exhibited improvement. These data indicate that the right ventricular dysfunction commonly associated with inferior wall infarction is often transient, and improvement is the rule, irrespective of early recanalization of the infarct vessel

  10. Parallel, but Dissociable, Processing in Discrete Corticostriatal Inputs Encodes Skill Learning.

    Science.gov (United States)

    Kupferschmidt, David A; Juczewski, Konrad; Cui, Guohong; Johnson, Kari A; Lovinger, David M

    2017-10-11

    Changes in cortical and striatal function underlie the transition from novel actions to refined motor skills. How discrete, anatomically defined corticostriatal projections function in vivo to encode skill learning remains unclear. Using novel fiber photometry approaches to assess real-time activity of associative inputs from medial prefrontal cortex to dorsomedial striatum and sensorimotor inputs from motor cortex to dorsolateral striatum, we show that associative and sensorimotor inputs co-engage early in action learning and disengage in a dissociable manner as actions are refined. Disengagement of associative, but not sensorimotor, inputs predicts individual differences in subsequent skill learning. Divergent somatic and presynaptic engagement in both projections during early action learning suggests potential learning-related in vivo modulation of presynaptic corticostriatal function. These findings reveal parallel processing within associative and sensorimotor circuits that challenges and refines existing views of corticostriatal function and expose neuronal projection- and compartment-specific activity dynamics that encode and predict action learning. Published by Elsevier Inc.

  11. Effects of metabolic syndrome on arterial function in different age groups: the Advanced Approach to Arterial Stiffness study.

    Science.gov (United States)

    Topouchian, Jirar; Labat, Carlos; Gautier, Sylvie; Bäck, Magnus; Achimastos, Apostolos; Blacher, Jacques; Cwynar, Marcin; de la Sierra, Alejandro; Pall, Denes; Fantin, Francesco; Farkas, Katalin; Garcia-Ortiz, Luis; Hakobyan, Zoya; Jankowski, Piotr; Jelakovic, Ana; Kobalava, Zhanna; Konradi, Alexandra; Kotovskaya, Yulia; Kotsani, Marina; Lazareva, Irina; Litvin, Alexander; Milyagin, Viktor; Mintale, Iveta; Persson, Oscar; Ramos, Rafael; Rogoza, Anatoly; Ryliskyte, Ligita; Scuteri, Angelo; Sirenko, Yuriy; Soulis, Georges; Tasic, Nebojsa; Udovychenko, Maryna; Urazalina, Saule; Wohlfahrt, Peter; Zelveian, Parounak; Benetos, Athanase; Asmar, Roland

    2018-04-01

    The aim of the Advanced Approach to Arterial Stiffness study was to compare arterial stiffness measured simultaneously with two different methods in different age groups of middle-aged and older adults with or without metabolic syndrome (MetS). The specific effects of the different MetS components on arterial stiffness were also studied. This prospective, multicentre, international study included 2224 patients aged 40 years and older, 1664 with and 560 without MetS. Patients were enrolled in 32 centres from 18 European countries affiliated to the International Society of Vascular Health & Aging. Arterial stiffness was evaluated using the cardio-ankle vascular index (CAVI) and the carotid-femoral pulse wave velocity (CF-PWV) in four prespecified age groups: 40-49, 50-59, 60-74, 75-90 years. In this report, we present the baseline data of this study. Both CF-PWV and CAVI increased with age, with a higher correlation coefficient for CAVI (comparison of coefficients P Age-adjusted and sex-adjusted values of CF-PWV and CAVI were weakly intercorrelated (r = 0.06, P Age-adjusted and sex-adjusted values for CF-PWV but not CAVI were higher in presence of MetS (CF-PWV: 9.57 ± 0.06 vs. 8.65 ± 0.10, P age on CAVI and CF-PWV and suggests that age may have a more pronounced effect on CAVI, whereas MetS increases CF-PWV but not CAVI. This important finding may be due to heterogeneous effects of MetS components on CAVI. The clinical significance of these original results will be assessed during the longitudinal phase of the study.

  12. [Baroreflexes originated in vertebral artery zones upon peripheral vein tonus, systemic arterial blood pressure, and external respiration].

    Science.gov (United States)

    Agadzhanian, N A; Kupriianov, S V

    2008-06-01

    The investigation was intended to study the role ofbaroreceptors ofhemodynamically isolated zone of vertebral arteries in regulation of peripheral veins tonus, arterial pressure and external respiration. Pressure decrease in this vascular reflexogenic zone led to reflex responses of increase in femoral vein tonus, elevation of blood pressure level and stimulation of external respiration. The opposite reflex responses of cardio-respiratory functional system to initial pressure activation of vertebral arteries baroreceptors are observed. Basing on generalization of our own findings and similar physiological and morphological researches of other authors, it is established that afferentation from the vertebral artery zone is a reflexogenic factor of somatic muscles' veins tonus regulation. These reflexes of capacity vessels tonic activity changes are part of cardio-respiratory responses of maintaining the tissue gaseous exchange.

  13. A time-resolved model of the mesospheric Na layer: constraints on the meteor input function

    Directory of Open Access Journals (Sweden)

    J. M. C. Plane

    2004-01-01

    Full Text Available A time-resolved model of the Na layer in the mesosphere/lower thermosphere region is described, where the continuity equations for the major sodium species Na, Na+ and NaHCO3 are solved explicity, and the other short-lived species are treated in steady-state. It is shown that the diurnal variation of the Na layer can only be modelled satisfactorily if sodium species are permanently removed below about 85 km, both through the dimerization of NaHCO3 and the uptake of sodium species on meteoric smoke particles that are assumed to have formed from the recondensation of vaporized meteoroids. When the sensitivity of the Na layer to the meteoroid input function is considered, an inconsistent picture emerges. The ratio of the column abundance of Na+ to Na is shown to increase strongly with the average meteoroid velocity, because the Na is injected at higher altitudes. Comparison with a limited set of Na+ measurements indicates that the average meteoroid velocity is probably less than about 25 km s-1, in agreement with velocity estimates from conventional meteor radars, and considerably slower than recent observations made by wide aperture incoherent scatter radars. The Na column abundance is shown to be very sensitive to the meteoroid mass input rate, and to the rate of vertical transport by eddy diffusion. Although the magnitude of the eddy diffusion coefficient in the 80–90 km region is uncertain, there is a consensus between recent models using parameterisations of gravity wave momentum deposition that the average value is less than 3×105 cm2 s-1. This requires that the global meteoric mass input rate is less than about 20 td-1, which is closest to estimates from incoherent scatter radar observations. Finally, the diurnal variation in the meteoroid input rate only slight perturbs the Na layer, because the residence time of Na in the layer is several days, and diurnal effects are effectively averaged out.

  14. Computer-assisted 3D reconstruction of the terminal branches of the cerebral arteries. Pt. 3. Posterior cerebral artery and circle of Willis

    International Nuclear Information System (INIS)

    Gloger, S.; Gloger, A.; Vogt, H.; Kretschmann, H.J.

    1994-01-01

    We present a three-dimensional anatomical computer model of the terminal branches of the posterior cerebral artery and circle of Willis, acquired from equidistant serial anatomical slices of three brains. The reconstructions provide a clear picture from all angles of the complicated course of the terminal branches of the cerebral arteries. This can help to identify the arteries in conventional and magnetic resonance angiography. Our rendition of the cerebral arteries can be matched with CT, MR and PET images to indicate the areas of extension of the individual branches, allowing neuromorphological and functional correlations. (orig.)

  15. Computer-assisted 3D reconstruction of the terminal branches of the cerebral arteries. Pt. 3. Posterior cerebral artery and circle of Willis

    Energy Technology Data Exchange (ETDEWEB)

    Gloger, S. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Gloger, A. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Vogt, H. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Kretschmann, H.J. (Dept. of Neuroanatomy, Hannover Medical School (Germany))

    1994-05-01

    We present a three-dimensional anatomical computer model of the terminal branches of the posterior cerebral artery and circle of Willis, acquired from equidistant serial anatomical slices of three brains. The reconstructions provide a clear picture from all angles of the complicated course of the terminal branches of the cerebral arteries. This can help to identify the arteries in conventional and magnetic resonance angiography. Our rendition of the cerebral arteries can be matched with CT, MR and PET images to indicate the areas of extension of the individual branches, allowing neuromorphological and functional correlations. (orig.)

  16. Latitudinal and seasonal variability of the micrometeor input function: A study using model predictions and observations from Arecibo and PFISR

    Science.gov (United States)

    Fentzke, J. T.; Janches, D.; Sparks, J. J.

    2009-05-01

    In this work, we use a semi-empirical model of the micrometeor input function (MIF) together with meteor head-echo observations obtained with two high power and large aperture (HPLA) radars, the 430 MHz Arecibo Observatory (AO) radar in Puerto Rico (18°N, 67°W) and the 450 MHz Poker flat incoherent scatter radar (PFISR) in Alaska (65°N, 147°W), to study the seasonal and geographical dependence of the meteoric flux in the upper atmosphere. The model, recently developed by Janches et al. [2006a. Modeling the global micrometeor input function in the upper atmosphere observed by high power and large aperture radars. Journal of Geophysical Research 111] and Fentzke and Janches [2008. A semi-empirical model of the contribution from sporadic meteoroid sources on the meteor input function observed at arecibo. Journal of Geophysical Research (Space Physics) 113 (A03304)], includes an initial mass flux that is provided by the six known meteor sources (i.e. orbital families of dust) as well as detailed modeling of meteoroid atmospheric entry and ablation physics. In addition, we use a simple ionization model to treat radar sensitivity issues by defining minimum electron volume density production thresholds required in the meteor head-echo plasma for detection. This simplified approach works well because we use observations from two radars with similar frequencies, but different sensitivities and locations. This methodology allows us to explore the initial input of particles and how it manifests in different parts of the MLT as observed by these instruments without the need to invoke more sophisticated plasma models, which are under current development. The comparisons between model predictions and radar observations show excellent agreement between diurnal, seasonal, and latitudinal variability of the detected meteor rate and radial velocity distributions, allowing us to understand how individual meteoroid populations contribute to the overall flux at a particular

  17. Arterial Stiffness in Children: Pediatric Measurement and Considerations

    Science.gov (United States)

    Savant, Jonathan D.; Furth, Susan L.; Meyers, Kevin E.C.

    2014-01-01

    Background Arterial stiffness is a natural consequence of aging, accelerated in certain chronic conditions, and predictive of cardiovascular events in adults. Emerging research suggests the importance of arterial stiffness in pediatric populations. Methods There are different indices of arterial stiffness. The present manuscript focuses on carotid-femoral pulse wave velocity and pulse wave analysis, although other methodologies are discussed. Also reviewed are specific measurement considerations for pediatric populations and the literature describing arterial stiffness in children with certain chronic conditions (primary hypertension, obesity, diabetes, chronic kidney disease, hypercholesterolemia, genetic syndromes involving vasculopathy, and solid organ transplant recipients). Conclusions The measurement of arterial stiffness in children is feasible and, under controlled conditions, can give accurate information about the underlying state of the arteries. This potentially adds valuable information about the functionality of the cardiovascular system in children with a variety of chronic diseases well beyond that of the brachial artery blood pressure. PMID:26587447

  18. Direct electrical stimulation as an input gate into brain functional networks: principles, advantages and limitations.

    Science.gov (United States)

    Mandonnet, Emmanuel; Winkler, Peter A; Duffau, Hugues

    2010-02-01

    While the fundamental and clinical contribution of direct electrical stimulation (DES) of the brain is now well acknowledged, its advantages and limitations have not been re-evaluated for a long time. Here, we critically review exactly what DES can tell us about cerebral function. First, we show that DES is highly sensitive for detecting the cortical and axonal eloquent structures. Moreover, DES also provides a unique opportunity to study brain connectivity, since each area responsive to stimulation is in fact an input gate into a large-scale network rather than an isolated discrete functional site. DES, however, also has a limitation: its specificity is suboptimal. Indeed, DES may lead to interpretations that a structure is crucial because of the induction of a transient functional response when stimulated, whereas (1) this effect is caused by the backward spreading of the electro-stimulation along the network to an essential area and/or (2) the stimulated region can be functionally compensated owing to long-term brain plasticity mechanisms. In brief, although DES is still the gold standard for brain mapping, its combination with new methods such as perioperative neurofunctional imaging and biomathematical modeling is now mandatory, in order to clearly differentiate those networks that are actually indispensable to function from those that can be compensated.

  19. Carotid artery stiffness, digital endothelial function, and coronary calcium in patients with essential thrombocytosis, free of overt atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Vrtovec Matjaz

    2017-05-01

    Full Text Available Patients with myeloproliferative neoplasms (MPNs are at increased risk for atherothrombotic events. Our aim was to determine if patients with essential thrombocytosis (ET, a subtype of MPNs, free of symptomatic atherosclerosis, have greater carotid artery stiffness, worse endothelial function, greater coronary calcium and carotid plaque burden than control subjects.

  20. Pseudo-BINPUT, a free formal input package for Fortran programmes

    International Nuclear Information System (INIS)

    Gubbins, M.E.

    1977-11-01

    Pseudo - BINPUT is an input package for reading free format data in codeword control in a FORTRAN programme. To a large degree it mimics in function the Winfrith Subroutine Library routine BINPUT. By using calls of the data input package DECIN to mimic the input routine BINPUT, Pseudo - BINPUT combines some of the advantages of both systems. (U.K.)

  1. Functional Relevance of Coronary Artery Disease by Cardiac Magnetic Resonance and Cardiac Computed Tomography: Myocardial Perfusion and Fractional Flow Reserve

    Directory of Open Access Journals (Sweden)

    Gianluca Pontone

    2015-01-01

    Full Text Available Coronary artery disease (CAD is one of the leading causes of morbidity and mortality and it is responsible for an increasing resource burden. The identification of patients at high risk for adverse events is crucial to select those who will receive the greatest benefit from revascularization. To this aim, several non-invasive functional imaging modalities are usually used as gatekeeper to invasive coronary angiography, but the diagnostic yield of elective invasive coronary angiography remains unfortunately low. Stress myocardial perfusion imaging by cardiac magnetic resonance (stress-CMR has emerged as an accurate technique for diagnosis and prognostic stratification of the patients with known or suspected CAD thanks to high spatial and temporal resolution, absence of ionizing radiation, and the multiparametric value including the assessment of cardiac anatomy, function, and viability. On the other side, cardiac computed tomography (CCT has emerged as unique technique providing coronary arteries anatomy and more recently, due to the introduction of stress-CCT and noninvasive fractional flow reserve (FFR-CT, functional relevance of CAD in a single shot scan. The current review evaluates the technical aspects and clinical experience of stress-CMR and CCT in the evaluation of functional relevance of CAD discussing the strength and weakness of each approach.

  2. Improvement of exercise ventricular function in patients of coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Kawasuji, Michio; Sawa, Shigeharu; Tedoriya, Takeo; Iwa, Takashi; Taki, Jun-ichi; Bunkou, Hisashi

    1989-01-01

    Thirty-five patients underwent exercise blood pool scintigraphy before and 4 weeks after coronary artery bypass graft (CABG). Left ventricular ejection fraction (EF), peak ejection rate (PER), peak filling rate (PFR), and one third peak filling rate (1/3 FR) were calculated. Exercise-induced EF was significantly higher after than before CABG (+2.4±6.1% vs -3.9±7.3%). Irrespective of exercise, preoperative PER was unchanged. Postoperative exercise significantly increased PER from 2.88±0.71 sec -1 to 3.85±0.85 sec -1 (p<0.01). Exercise also significantly increased PFR after GABG when compared with that before GABF. 1/3FR did not differ before and after CABG. Exercise blood pool scintigraphy was useful in evaluating ventricular function before and after CABG. (Namekawa, K)

  3. Whole-body vibration as a potential countermeasure for dynapenia and arterial stiffness

    Directory of Open Access Journals (Sweden)

    Arturo Figueroa

    2016-09-01

    Full Text Available Age-related decreases in muscle mass and strength are associated with decreased mobility, quality of life, and increased cardiovascular risk. Coupled with the prevalence of obesity, the risk of death becomes substantially greater. Resistance training (RT has a well-documented beneficial impact on muscle mass and strength in young and older adults, although the high-intensity needed to elicit these adaptations may have a detrimental or negligible impact on vascular function, specifically on arterial stiffness. Increased arterial stiffness is associated with systolic hypertension, left ventricular hypertrophy, and myocardial ischemia. Therefore, improvements of muscle strength and arterial function are important in older adults. Recently, whole-body vibration (WBV exercise, a novel modality of strength training, has shown to exhibit similar results on muscle strength as RT in a wide-variety of populations, with the greatest impact in elderly individuals with limited muscle function. Additionally, WBV training has been shown to have beneficial effects on vascular function by reducing arterial stiffness. This article reviews relevant publications reporting the effects of WBV on muscle strength and/or arterial stiffness. Findings from current studies suggest the use of WBV training as an alternative modality to traditional RT to countermeasure the age-related detriments in muscle strength and arterial stiffness in older adults.

  4. Whole-body vibration as a potential countermeasure for dynapenia and arterial stiffness.

    Science.gov (United States)

    Figueroa, Arturo; Jaime, Salvador J; Alvarez-Alvarado, Stacey

    2016-09-01

    Age-related decreases in muscle mass and strength are associated with decreased mobility, quality of life, and increased cardiovascular risk. Coupled with the prevalence of obesity, the risk of death becomes substantially greater. Resistance training (RT) has a well-documented beneficial impact on muscle mass and strength in young and older adults, although the high-intensity needed to elicit these adaptations may have a detrimental or negligible impact on vascular function, specifically on arterial stiffness. Increased arterial stiffness is associated with systolic hypertension, left ventricular hypertrophy, and myocardial ischemia. Therefore, improvements of muscle strength and arterial function are important in older adults. Recently, whole-body vibration (WBV) exercise, a novel modality of strength training, has shown to exhibit similar results on muscle strength as RT in a wide-variety of populations, with the greatest impact in elderly individuals with limited muscle function. Additionally, WBV training has been shown to have beneficial effects on vascular function by reducing arterial stiffness. This article reviews relevant publications reporting the effects of WBV on muscle strength and/or arterial stiffness. Findings from current studies suggest the use of WBV training as an alternative modality to traditional RT to countermeasure the age-related detriments in muscle strength and arterial stiffness in older adults.

  5. Characteristics of Carotid Artery Structure and Mechanical Function and Their Relationships with Aortopathy in Patients with Bicuspid Aortic Valves

    Directory of Open Access Journals (Sweden)

    Mihyun Kim

    2017-08-01

    Full Text Available Patients with a bicuspid aortic valve (BAV often have proximal aortic dilatation and systemic vascular dysfunction. We hypothesized that BAV patients would have different carotid artery structural and functional characteristics compared to tricuspid aortic valve (TAV patients. In 28 patients with surgically confirmed BAV and 27 patients with TAV, intima media thickness (IMT, number of plaques, fractional area change (FAC, global circumferential strain (GCS, and standard deviation of CS (SD-CS in both common carotid arteries were assessed using duplex ultrasound and velocity vector imaging (VVI. Patients with BAV were younger and had less co-morbidity, but showed a significantly larger ascending aorta (43.3 ± 7.5 vs. 37.0 ± 6.2 mm, p < 0.001 and a higher prevalence of aortopathy (61 vs. 30%, p = 0.021 than those with TAV. BAV patients showed a significantly lower IMT and fewer plaques. Although FAC and GCS were not significantly different between the two groups, they tended to be lower in the BAV group when each group was divided into three subgroups according to age. There was a significant age-dependent increase in IMT and decreases in FAC and GCS in the TAV group (p = 0.005, p = 0.001, p = 0.002, respectively, but this phenomenon was not evident in the BAV group (p = 0.074, p = 0.248, p = 0.394, respectively. BAV patients with aortopathy showed a higher SD-CS than those without aortopathy (p = 0.040, reflecting disordered mechanical function. In conclusion, BAV patients have different carotid artery structure and function compared with TAV patients, suggesting intrinsic vascular abnormalities that are less affected by established cardiovascular risk factors and more strongly related to the presence of aortopathy.

  6. Bypass grafting to the anterior tibial artery.

    Science.gov (United States)

    Armour, R H

    1976-01-01

    Four patients with severe ischaemia of a leg due to atherosclerotic occlusion of the tibial and peroneal arteries had reversed long saphenous vein grafts to the patent lower part of the anterior tibial artery. Two of these grafts continue to function 19 and 24 months after operation respectively. One graft failed on the fifth postoperative day and another occluded 4 months after operation. The literature on femorotibial grafting has been reviewed. The early failure rate of distal grafting is higher than in the case of femoropopliteal bypass, but a number of otherwise doomed limbs can be salvaged. Contrary to widely held views, grafting to the anterior tibial artery appears to give results comparable to those obtained when the lower anastomosis is made to the posterior tibial artery.

  7. Impact of acute caffeine ingestion on endothelial function in subjects with and without coronary artery disease.

    Science.gov (United States)

    Shechter, Michael; Shalmon, Guy; Scheinowitz, Mickey; Koren-Morag, Nira; Feinberg, Micha S; Harats, Dror; Sela, Ben Ami; Sharabi, Yehonatan; Chouraqui, Pierre

    2011-05-01

    Although coffee is a widely used, pharmacologically active beverage, its impact on the cardiovascular system is controversial. To explore the effect of acute caffeine ingestion on brachial artery flow-mediated dilation (FMD) in subjects without coronary artery disease (CAD; controls) and patients with CAD, we prospectively assessed brachial artery FMD in 40 controls and 40 age- and gender-matched patients with documented stable CAD on 2 separate mornings 1 week to 2 weeks apart. After overnight fasting, discontinuation of all medications for ≥12 hours, and absence of caffeine for >48 hours, participants received capsules with caffeine 200 mg or placebo. One hour after drug ingestion, participants underwent brachial artery FMD and nitroglycerin-mediated dilation (NTG) using high-resolution ultrasound. As expected, patients with CAD were more often diabetic, hypertensive, obese, dyslipidemic, and smoked more than controls (p <0.01 for all comparisons). Aspirin, Clopidogrel, angiotensin-converting enzyme inhibitors, β blockers, and statins were significantly more common in patients with CAD than in controls (p <0.01 for all comparisons). At baseline, FMD, but not NTG, was significantly lower in patients with CAD compared to controls. Acute caffeine ingestion significantly increased FMD (patients with CAD 5.6 ± 5.0% vs 14.6 ± 5.0%, controls 8.4 ± 2.9% vs 18.6 ± 6.8%, p <0.001 for all comparisons) but not NTG (patients with CAD 13.0 ± 5.2% vs 13.8 ± 6.1%, controls 12.9 ± 3.9% vs 13.9 ± 5.8%, p = NS for all comparisons) and significantly decreased high-sensitivity C-reactive protein (patients with CAD 2.6 ± 1.4 vs 1.4 ± 1.2 mg/L, controls 3.4 ± 3.0 vs 1.2 ± 1.0 mg/L, p <0.001 for all comparisons) in the 2 groups compared to placebo. In conclusion, acute caffeine ingestion significantly improved endothelial function assessed by brachial artery FMD in subjects with and without CAD and was associated with lower plasma markers of inflammation. Copyright

  8. ARTERIAL REVASCULARIZATION WITH THE RIGHT GASTROEPIPLOIC ARTERY AND INTERNAL MAMMARY ARTERIES IN 300 PATIENTS

    NARCIS (Netherlands)

    GRANDJEAN, JG; BOONSTRA, PW; DENHEYER, P; EBELS, T; KIRKLIN, JW

    From September 1989 to September 1992, the right gastroepiploic artery in combination with one or both internal mammary arteries was used as a graft in 300 patients who underwent coronary artery bypass grafting. The gastroepiploic artery was the primary choice in preference to the saphenous vein.

  9. Fibulin-4 is essential for maintaining arterial wall integrity in conduit but not muscular arteries.

    Science.gov (United States)

    Halabi, Carmen M; Broekelmann, Thomas J; Lin, Michelle; Lee, Vivian S; Chu, Mon-Li; Mecham, Robert P

    2017-05-01

    Homozygous or compound heterozygous mutations in fibulin-4 ( FBLN4 ) lead to autosomal recessive cutis laxa type 1B (ARCL1B), a multisystem disorder characterized by significant cardiovascular abnormalities, including abnormal elastin assembly, arterial tortuosity, and aortic aneurysms. We sought to determine the consequences of a human disease-causing mutation in FBLN4 (E57K) on the cardiovascular system and vascular elastic fibers in a mouse model of ARCL1B. Fbln4 E57K/E57K mice were hypertensive and developed arterial elongation, tortuosity, and ascending aortic aneurysms. Smooth muscle cell organization within the arterial wall of large conducting vessels was abnormal, and elastic fibers were fragmented and had a moth-eaten appearance. In contrast, vessel wall structure and elastic fiber integrity were normal in resistance/muscular arteries (renal, mesenteric, and saphenous). Elastin cross-linking and total elastin content were unchanged in large or small arteries, whereas elastic fiber architecture was abnormal in large vessels. While the E57K mutation did not affect Fbln4 mRNA levels, FBLN4 protein was lower in the ascending aorta of mutant animals compared to wild-type arteries but equivalent in mesenteric arteries. We found a differential role of FBLN4 in elastic fiber assembly, where it functions mainly in large conduit arteries. These results suggest that elastin assembly has different requirements depending on vessel type. Normal levels of elastin cross-links in mutant tissue call into question FBLN4's suggested role in mediating lysyl oxidase-elastin interactions. Future studies investigating tissue-specific elastic fiber assembly may lead to novel therapeutic interventions for ARCL1B and other disorders of elastic fiber assembly.

  10. Long-term excess fat and/or fructose ingestion causes changes in small artery K+ transporter expression and function with effects on blood pressure

    DEFF Research Database (Denmark)

    Olsen, A. K.; Salomonsson, M.; Sørensen, C. M.

    + channels, Na/K-ATPase, and voltage-gated Ca2+ channels are crucial determinants of resistance artery tone. Only scarce information is available on the role of K+ transporters in pathophysiological mechanisms induced by long-term feeding of laboratory rats with either high-fat, high-fructose or high-fat/high-fructose...... diet. HYPOTHESIS: A 28-week diet consisting of high-fat or high-fructose, or both, will lead to changes in K+ transporter expression and function, which will be linked with changes in blood pressure, arterial smooth muscle function, endothelial function and passive structural/mechanical properties....... METHODS: Male Sprague Dawley rats (4 weeks) were randomized into 4 diet groups receiving a diet with normal chow (CTR, N=19), high-fat chow (60% saturated fat, FAT, N=18), high-fructose (10% in drinking water; FRUC, N=15), or a combination of fat/fructose (FAT/FRUC, N=15) for 28 weeks. Systolic blood...

  11. Interventional treatment of emergent hepatic artery thrombosis after liver transplantation

    International Nuclear Information System (INIS)

    Liu Fengyong; Wang Maoqiang; Wang Zhijun; Wang Zhongpu; Shi Xianjie; Zhou Ningxin

    2006-01-01

    Objective: To evaluate the safety and efficacy of the endovascular interventional techniques for the management of emergent hepatic artery thrombosis (HAT) after orthotopic liver transplantation (OLT). Methods: Ten patients (8 men and 2 women with mean age of 47 years) diagnosed with HAT after OLT were treated with interventional procedures. All patients presented with elevation of liver enzymes and bilirubin levels. The diagnosis of the HAT was suggested by doppler ultrasonography and confirmed by angiography at 16 hours to 10 days (mean, 4.5 days) after OLT. Interventional techniques consisted of indwelling transcatheter hepatic arterial thrombolysis with a low dose of urokinase monitored under ultrasonography every 6-12 hours and stent placement in the stenotic segment of the hepatic artery was undertaken. Systemic intravenous low dose of heparin was given contemporaneously. Results: Complete occlusion of the proper HA was achieved in 10 patients. Hepatic arterial flow was re-established in 8 of the 10 patients (80%) at 12 hours to 9 days (mean, 4.8 days) after the intra-arterial thrombolysis, with significant improvement of liver function. Hepatic artery stenosis at the anastomosis was found in the 8 patients, and a stent placement in the stenotic segment was performed successfully in 7 patients with degree of stenosis over 90%.Intra-arterial thrombolysis was failed in 2 cases. Intraperitoneal hemorrhage from the anastomosis occurred in 1 patient at 12 hours after the treatment, and was emergently taken for the graft revision with reanastomosis. One patient with complete occlusion of the hepatic artery at 7 days after the treatment, but having collateral flow of the liver for maintaining liver function and thus sparing further intervention. 8 patients with successful hepatic arterial recanalization carried along a good clinical course with normal graft function at a median 12 months (range, 4 to 20 months), and patent hepatic arterial flow was identified by

  12. [Anatomy character of renal artery and treatment of living-donor renal transplantation].

    Science.gov (United States)

    Zhang, Lei; Fei, Ji-guang; Chen, Li-zhong; Wang, Chang-xi; Deng, Su-xiong; Qiu, Jiang; Li, Jun; Chen, Guo-dong; Huang, Gang

    2009-12-15

    To study the anatomy characters of renal artery and the treatment of multiple arteries in living donor renal grafts. Records of 142 living donors were analyzed in our center. We analyzed the anatomic structure of renal arteries by DSA and CTA pre-transplantation. Thirty-one kidneys with multiple arteries were transplanted after reconstruction. Then clinical effects were compared between multiple-renal-arteries group (n=31) and single-renal-artery group (n=111). The incidence of multiple renal artery was 30.99%, and there was no difference between both sides (left kidney 22.54%, right kidney 22.13%). If the multiple artery occurred in left or right kidney, the incidence of the multiple artery occurred in the other side was 56.25% and 60.00%, respectively. The diameter of left main renal artery was more magnanimous (P=0.001) and the first branch was more closed to abdominal aorta (P=0.004). Operation time and warm/cool ischemia time were longer in the multiple-renal-arteries group. However, estimated blood loss, delayed graft function, acute rejection and flow rate of arcuate artery were similar in both groups, the same as serum creatinine and serum creatinine clearance rate on day 7, 1 month and 3 month post-operation. It was shown by repeated measures ANOVA that graft with multiple arteries didn't affect the tendency of renal function at early time post-operation. Comprehending the character of renal artery and accurate treatment of multiple artery anastomosis are critical for the effect of the living kidney transplantation.

  13. Exercise promotes collateral artery growth mediated by monocytic nitric oxide.

    Science.gov (United States)

    Schirmer, Stephan H; Millenaar, Dominic N; Werner, Christian; Schuh, Lisa; Degen, Achim; Bettink, Stephanie I; Lipp, Peter; van Rooijen, Nico; Meyer, Tim; Böhm, Michael; Laufs, Ulrich

    2015-08-01

    Collateral artery growth (arteriogenesis) is an important adaptive response to hampered arterial perfusion. It is unknown whether preventive physical exercise before limb ischemia can improve arteriogenesis and modulate mononuclear cell function. This study aimed at investigating the effects of endurance exercise before arterial occlusion on MNC function and collateral artery growth. After 3 weeks of voluntary treadmill exercise, ligation of the right femoral artery was performed in mice. Hindlimb perfusion immediately after surgery did not differ from sedentary mice. However, previous exercise improved perfusion restoration ≤7 days after femoral artery ligation, also when exercise was stopped at ligation. This was accompanied by an accumulation of peri-collateral macrophages and increased expression of endothelial nitric oxide synthase and inducible nitric oxide synthase (iNOS) in hindlimb collateral and in MNC of blood and spleen. Systemic monocyte and macrophage depletion by liposomal clodronate but not splenectomy attenuated exercise-induced perfusion restoration, collateral artery growth, peri-collateral macrophage accumulation, and upregulation of iNOS. iNOS-deficient mice did not show exercise-induced perfusion restoration. Transplantation of bone marrow-derived MNC from iNOS-deficient mice into wild-type animals inhibited exercise-induced collateral artery growth. In contrast to sedentary controls, thrice weekly aerobic exercise training for 6 months in humans increased peripheral blood MNC iNOS expression. Circulating mononuclear cell-derived inducible nitric oxide is an important mediator of exercise-induced collateral artery growth. © 2015 American Heart Association, Inc.

  14. Occipital Artery Function during the Development of 2-Kidney, 1-Clip Hypertension in Rats

    OpenAIRE

    Stephen P. Chelko; Chad W. Schmiedt; Tristan H. Lewis; Tom P. Robertson; Stephen J. Lewis

    2014-01-01

    This study compared the contractile responses elicited by angiotensin II (AII), arginine vasopressin (AVP), and 5-hydroxytryptamine (5-HT) in isolated occipital arteries (OAs) from sham-operated (SHAM) and 2-kidney, 1-clip (2K-1C) hypertensive rats. OAs were isolated and bisected into proximal segments (closer to the common carotid artery) and distal segments (closer to the nodose ganglion) and mounted separately on myographs. On day 9, 2K-1C rats had higher mean arterial blood pressures, hea...

  15. Outcomes of anatomical versus functional testing for coronary artery disease.

    Science.gov (United States)

    Douglas, Pamela S; Hoffmann, Udo; Patel, Manesh R; Mark, Daniel B; Al-Khalidi, Hussein R; Cavanaugh, Brendan; Cole, Jason; Dolor, Rowena J; Fordyce, Christopher B; Huang, Megan; Khan, Muhammad Akram; Kosinski, Andrzej S; Krucoff, Mitchell W; Malhotra, Vinay; Picard, Michael H; Udelson, James E; Velazquez, Eric J; Yow, Eric; Cooper, Lawton S; Lee, Kerry L

    2015-04-02

    Many patients have symptoms suggestive of coronary artery disease (CAD) and are often evaluated with the use of diagnostic testing, although there are limited data from randomized trials to guide care. We randomly assigned 10,003 symptomatic patients to a strategy of initial anatomical testing with the use of coronary computed tomographic angiography (CTA) or to functional testing (exercise electrocardiography, nuclear stress testing, or stress echocardiography). The composite primary end point was death, myocardial infarction, hospitalization for unstable angina, or major procedural complication. Secondary end points included invasive cardiac catheterization that did not show obstructive CAD and radiation exposure. The mean age of the patients was 60.8±8.3 years, 52.7% were women, and 87.7% had chest pain or dyspnea on exertion. The mean pretest likelihood of obstructive CAD was 53.3±21.4%. Over a median follow-up period of 25 months, a primary end-point event occurred in 164 of 4996 patients in the CTA group (3.3%) and in 151 of 5007 (3.0%) in the functional-testing group (adjusted hazard ratio, 1.04; 95% confidence interval, 0.83 to 1.29; P=0.75). CTA was associated with fewer catheterizations showing no obstructive CAD than was functional testing (3.4% vs. 4.3%, P=0.02), although more patients in the CTA group underwent catheterization within 90 days after randomization (12.2% vs. 8.1%). The median cumulative radiation exposure per patient was lower in the CTA group than in the functional-testing group (10.0 mSv vs. 11.3 mSv), but 32.6% of the patients in the functional-testing group had no exposure, so the overall exposure was higher in the CTA group (mean, 12.0 mSv vs. 10.1 mSv; P<0.001). In symptomatic patients with suspected CAD who required noninvasive testing, a strategy of initial CTA, as compared with functional testing, did not improve clinical outcomes over a median follow-up of 2 years. (Funded by the National Heart, Lung, and Blood Institute

  16. Regional blood flow analysis and its relationship with arterial branch lengths and lumen volume in the coronary arterial tree

    International Nuclear Information System (INIS)

    Molloi, Sabee; Wong, Jerry T

    2007-01-01

    The limitations of visually assessing coronary artery disease are well known. These limitations are particularly important in intermediate coronary lesions (30-70% diameter stenosis) where it is difficult to determine whether a particular lesion is the cause of ischaemia. Therefore, a functional measure of stenosis severity is needed. The purpose of this study is to determine whether the expected maximum coronary blood flow in an arterial tree is predictable from its sum of arterial branch lengths or lumen volume. Using a computer model of a porcine coronary artery tree, an analysis of blood flow distribution was conducted through a network of millions of vessels that included the entire coronary artery tree down to the first capillary branch. The flow simulation results show that there is a linear relationship between coronary blood flow and the sum of its arterial branch lengths. This relationship holds over the entire arterial tree. The flow simulation results also indicate that there is a 3/4 er relation between coronary blood flow (Q) and the sum of its arterial lumen volume (V). Moreover, there is a linear relationship between normalized Q and normalized V raised to a power of 3/4 over the entire arterial tree. These results indicate that measured arterial branch lengths or lumen volumes can be used to predict the expected maximum blood flow in an arterial tree. This theoretical maximum blood flow, in conjunction with an angiographically measured blood flow, can potentially be used to calculate fractional flow reserve based entirely on angiographic data

  17. Pulmonary arterial hypertension secondary to chronic thromboemboli

    International Nuclear Information System (INIS)

    Crysikopoulos, H.; Forrest, J.V.; Olson, L.K.; Roberts, A.C.

    1989-01-01

    The authors report their experience in 150 patients with pulmonary arterial hypertension secondary to chronic pulmonary embolism (CPE). Plain film findings are variable, commonly nonspecific. Occasionally nonuniformity of pulmonary perfusion or truncation of central pulmonary arteries suggest CPE. Multiple, large, unmatched perfusion defects are the most common scintigraphic observations. CT can exclude conditions mimicking CPE, particularly fibrosing mediastinitis. Pulmonary arteriography depicts the location and distribution of emboli. CPE is becoming an increasingly important entity to recognize because of available surgical treatment. Thromboendarterectomy may improve functional status and survival. The diagnosis should be considered in any patient with pulmonary arterial hypertension

  18. [Ultrasonographic evaluation of selected parameters of the endothelial function in brachial arteries and IMT measurements in carotid arteries in children with diabetes type 1 using personal insulin pumps--preliminary report].

    Science.gov (United States)

    Tołwińska, Joanna; Głowińska-Olszewska, Barbara; Urban, Mirosława; Florys, Bozena; Peczyńska, Jadwiga

    2006-01-01

    endothelial function in type 1 diabetic children and seems to be a significant tool in delaying the atherosclerotic process. 2. We need more examinations to explain the role of treatment intensification in common carotid arteries wall morphology in type 1 diabetic children. 3. The ultrasonographic detection of atherosclerotic changes in arterial vessels can help in the evaluation of the changes due to different methods of diabetes treatment.

  19. Close to Transplant Renal Artery Stenosis and Percutaneous Transluminal Treatment

    Directory of Open Access Journals (Sweden)

    Leonardou Polytimi

    2011-01-01

    Full Text Available Purpose. To evaluate the efficacy of percutaneous transluminal angioplasty (PTA in the management of arterial stenosis located close to the allograft anastomosis (close-TRAS. Materials and Methods. 31 patients with renal transplants were admitted to our institution because of persistent hypertension and impairment of transplant renal function and underwent angiography for vascular investigation. 27 were diagnosed suffering from transplant renal artery stenosis (TRAS, whereas 4 had severe iliac artery stenosis proximal to the transplant anastomosis (Prox-TRAS. 3 cases of TRAS coexisted with segmental renal arterial stenosis, whereas 3 other cases of TRAS were caused by kinking and focal stenosis in the middle of the transplanted renal artery. Results. Angioplasty and stenting were successfully applied to all patients with iliac artery stenosis as well as to those with TRAS and segmental artery stenosis. Two of three patients with kinking were well treated with angioplasty and stenting, whereas one treated only with angioplasty necessitated surgery. No major procedure-related complications appeared, and the result was decrease of the serum creatinine level and of the blood pressure. Conclusions. PTA is the appropriate initial treatment of TRAS and close-TRAS, with low morbidity and mortality rates, achieving improvement of graft function and amelioration of hypertension.

  20. Serotonin 1B Receptors Regulate Prefrontal Function by Gating Callosal and Hippocampal Inputs

    DEFF Research Database (Denmark)

    Kjaerby, Celia; Athilingam, Jegath; Robinson, Sarah E

    2016-01-01

    Both medial prefrontal cortex (mPFC) and serotonin play key roles in anxiety; however, specific mechanisms through which serotonin might act on the mPFC to modulate anxiety-related behavior remain unknown. Here, we use a combination of optogenetics and synaptic physiology to show that serotonin...... acts presynaptically via 5-HT1B receptors to selectively suppress inputs from the contralateral mPFC and ventral hippocampus (vHPC), while sparing those from mediodorsal thalamus. To elucidate how these actions could potentially regulate prefrontal circuit function, we infused a 5-HT1B agonist...... into the mPFC of freely behaving mice. Consistent with previous studies that have optogenetically inhibited vHPC-mPFC projections, activating prefrontal 5-HT1B receptors suppressed theta-frequency mPFC activity (4-12 Hz), and reduced avoidance of anxiogenic regions in the elevated plus maze. These findings...

  1. The internal carotid artery stenosis or occlusion. The evaluation for the posterior communicating artery on DSA and MRA

    International Nuclear Information System (INIS)

    Zhao Yunhui; Gao Xinjiang; Ma Zhubin; Xu Yikai

    2003-01-01

    Objective: To study the changes of the posterior communicating artery in patients with internal carotid artery (ICA) severe stenosis or occlusion on digital subtract angiography (DSA) and magnetic resonance angiography (MRA). Methods: DSA or MRA findings were analyzed in 74 patients with ICA stenosis or occlusion and in 120 persons selected in the control group, who were unremarkable on cerebral DSA or MRA. Results: On DSA, the presence rate of ipsilateral posterior communicating artery (PCoA) between the study group and the control group had no significant difference; on MRA the rate in the study group was significantly higher than the control group (P 0.05). In the study group, the presence rate of PCoA on DSA was significantly higher than that on MRA (P 0.05). The presence rate of PCoA shown no significant difference between the cases with unilateral ICA involved and cases with bilateral ICA involved. Conclusion: The posterior communicating artery is very important to the patients with the internal carotid artery stenosis or occlusion. Its dilatation on DSA and MRA or appearance on MRA shows its compensation. DSA is valuable in the evaluation of the posterior communicating artery. MRA is a noninvasive and functional imaging method for evaluation the posterior communicating artery

  2. Evaluation of Cardiac and Valvular Function after Arterial Switch Operation: A Midterm Follow-Up

    Directory of Open Access Journals (Sweden)

    Hamid Amoozgar

    2013-09-01

    Full Text Available Objectives: Transposition of Great Arteries (TGA is a serious congenital heart disease and anatomic correction in the first few weeks of life has revealed good outcomes nowadays. In this study, we aimed to evaluate the myocardial and valvular function at midterm postoperative follow-up. Patients and Methods: In this study, thirty-three patients with TGA and Arterial Switch Operation (ASO were evaluated by 2-dimensional, M-mode, Doppler, and pulsed Tissue Doppler. These patients were compared with 33 healthy children of the same age and gender as the normal control group. Student’s t-test and Pearson correlation were used to analyze the data. Besides, P<0.05 was considered as statistically significant. Results: The mean follow up time was 40.9±5.6 months. Among the 33 patients with ASO, 6% had mild pulmonary stenosis, while 3% had mild pulmonary insufficiency. Aortic stenosis and aortic insufficiency of trivial to mild degree was seen in 12% and 12% of the patients, respectively. The patients’ systolic velocity of tricuspid (S, early diastolic velocity of tricuspid (Ea, and late velocity of tricuspid valve (Aa were significantly different from those of the controls (P<0.001. Also, pulmonary annulus diameter was significantly dilated in the patients compared to the controls (1.67±0.41 vs. 1.29±0.28, P≤0.001. Besides, aortic annulus diameter (1.56±0.42 vs. 1.24±0.21, P=0.001 and also aortic sinus diameter (2.06±0.41 vs. 1.44±0.34, P=0.002 were significantly dilated, while sinutuboar junction diameter (1.65±0.5 vs. 1.28±0.29, P=0.094 was not dilated. Left ventricular function was in the normal range. Conclusions: This study showed good left ventricular function, but some abnormalities in lateral tricuspid tissue Doppler velocities. Neoaortic and pulmonary diameters were significantly dilated, while aortic and pulmonary insufficiencies were clinically insignificant in most of the patients. Long-term follow-up is necessary in these

  3. Valutazione morfo-funzionale in pazienti ipertesi con stenosi dell'arteria renale; Correlazioni tra angiografia e scintigrafia dinamica. Morpho-functional evaluation in hypertensive patients with renal artery stenosis; Correlations between angiography and radionuclide renography

    Energy Technology Data Exchange (ETDEWEB)

    Cuocolo, A; Celentano, L; Nappi, A [Naples Univ. (Italy). Ist. di Scienze Radiologiche; Neumann, R D; Salvatore, M [Naples Univ. (Italy). Cattedra di Medicina Nucleare

    1991-01-01

    Renovascula hypertension is the most important and common cause of secondary hypertension. We studied 10 patients with arterial hypertension and different degrees of renal artery stenosis to assess the usefulness of dynamic radionuclide renography in evaluating renal perfusion and funcion, and to compare funcional radionuclide results to the morphological findings of renal angiography. Computer-assisted dynamic renal with {sup 00m}Tc diethylenetriaminepentaacetic acid (DTPA) and {sup 131}I orthoiodohippurate (OIH), and renal artheriography were also employed in all patients. In all patients, radionuclide results matched angiography findings in quality. In particular, 3 patients with hemodynamical insignificant renal artery stenosis exhibited normal perfusion and function at dynamic radionuclide renography. Seven patients had significant renal artery stenosis and associated functional changes at dynamic radionuclide renography. Quantitative comparison of all patients showed a significant correlation (r=0.866, p<0.001) between the degree of renal artery stenosis, quantified as the percentage of narrowing as compared to adjacent/contralateral normal vessel diameter, and the results of split renal function, as assessed during OIH studies and expressed per kidney as a percentage of the net total counts of both kidneys. In conclusion, our results demonstrated dynamic radionuclide renography to be a valuable secondary to renal artery stenosis in hypertensive patients, providing complementary results to arteriography.

  4. Comparably improved health-related quality of life after total arterial revascularization versus conventional coronary surgery--Copenhagen arterial revascularization randomized patency and outcome trial

    DEFF Research Database (Denmark)

    Damgaard, Sune; Lund, Jens T; Lilleør, Nikolaj B

    2011-01-01

    OBJECTIVE: We compared health-related quality of life up to 11 months after coronary artery bypass grafting using total arterial revascularization versus conventional coronary surgery. METHODS: In this randomized single-center trial, 161 patients underwent total arterial revascularization using.......01). For total arterial revascularization, there were also not statistically significant improvements for 'physical component summary' (P=0.09), 'bodily pain' (P=0.07) and 'vitality' (P=0.08). CONCLUSION: Health-related quality of life up to 1 year after total arterial revascularization is equal or slightly...... of the general Danish population. On all scales of the SF-36, there was statistically significant improvement at 3 and 11 months in both groups. For 'social functioning', the improvement following total arterial revascularization was significantly higher than following conventional revascularization (P=0...

  5. Calibrated image-derived input functions for the determination of the metabolic uptake rate of glucose with [18F]-FDG PET

    DEFF Research Database (Denmark)

    Christensen, Anders Nymark; Reichkendler, Michala H.; Larsen, Rasmus

    2014-01-01

    We investigated the use of a simple calibration method to remove bias in previously proposed approaches to image-derived input functions (IDIFs) when used to calculate the metabolic uptake rate of glucose (Km) from dynamic [18F]-FDG PET scans of the thigh. Our objective was to obtain nonbiased, low...

  6. Stabilization of (state, input)-disturbed CSTRs through the port-Hamiltonian systems approach

    OpenAIRE

    Lu, Yafei; Fang, Zhou; Gao, Chuanhou

    2017-01-01

    It is a universal phenomenon that the state and input of the continuous stirred tank reactor (CSTR) systems are both disturbed. This paper proposes a (state, input)-disturbed port-Hamiltonian framework that can be used to model and further designs a stochastic passivity based controller to asymptotically stabilize in probability the (state, input)-disturbed CSTR (sidCSTR) systems. The opposite entropy function and the availability function are selected as the Hamiltonian for the model and con...

  7. Computer Generated Inputs for NMIS Processor Verification

    International Nuclear Information System (INIS)

    J. A. Mullens; J. E. Breeding; J. A. McEvers; R. W. Wysor; L. G. Chiang; J. R. Lenarduzzi; J. T. Mihalczo; J. K. Mattingly

    2001-01-01

    Proper operation of the Nuclear Identification Materials System (NMIS) processor can be verified using computer-generated inputs [BIST (Built-In-Self-Test)] at the digital inputs. Preselected sequences of input pulses to all channels with known correlation functions are compared to the output of the processor. These types of verifications have been utilized in NMIS type correlation processors at the Oak Ridge National Laboratory since 1984. The use of this test confirmed a malfunction in a NMIS processor at the All-Russian Scientific Research Institute of Experimental Physics (VNIIEF) in 1998. The NMIS processor boards were returned to the U.S. for repair and subsequently used in NMIS passive and active measurements with Pu at VNIIEF in 1999

  8. Relations of Digital Vascular Function, Cardiovascular Risk Factors, and Arterial Stiffness: The Brazilian Longitudinal Study of Adult Health (ELSA‐Brasil) Cohort Study

    Science.gov (United States)

    Brant, Luisa C. C.; Hamburg, Naomi M.; Barreto, Sandhi M.; Benjamin, Emelia J.; Ribeiro, Antonio L. P.

    2014-01-01

    Background Vascular dysfunction is an early expression of atherosclerosis and predicts cardiovascular (CV) events. Peripheral arterial tonometry (PAT) evaluates basal pulse amplitude (BPA), endothelial function (PAT ratio), and wave reflection (PAT‐AIx) in the digital microvessels. In Brazilian adults, we investigated the correlations of PAT responses to CV risk factors and to carotid‐femoral pulse wave velocity (PWV), a measure of arterial stiffness. Methods and Results In a cross‐sectional study, 1535 participants of the ELSA‐Brasil cohort underwent PAT testing (52±9 years; 44% women). In multivariable analyses, more‐impaired BPA and PAT ratios were associated with male sex, higher body mass index (BMI), and total cholesterol/high‐density lipoprotein. Higher age and triglycerides were related to higher BPA, whereas lower systolic blood pressure, hypertension (HTN) treatment, and prevalent CV disease (CVD) were associated with lower PAT ratio. PAT‐AIx correlated positively with female sex, advancing age, systolic and diastolic blood pressures, and smoking and inversely to heart rate, height, BMI, and prevalent CVD. Black race was associated with lower BPA, higher PAT ratio, and PAT‐AIx. Microvessel vasodilator function was not associated with PWV. Higher PAT‐AIx was modestly correlated to higher PWV and PAT ratio and inversely correlated to BPA. Conclusion Metabolic risk factors are related to impaired microvessel vasodilator function in Brazil. However, in contrast to studies from the United States, black race was not associated with an impaired microvessel vasodilator response, implying that vascular function may vary by race across populations. PAT‐AIx relates to HTN, may be a valid measure of wave reflection, and provides distinct information from arterial stiffness. PMID:25510401

  9. Quantitative evaluation of the structure and function of the common carotid artery in hypertriglyceridemic subjects using ultrasound radiofrequency-data technology

    International Nuclear Information System (INIS)

    Dan, Hai-Jun; Wang, Yan; Sha, Hai-Jing; Wen, Shu-Bin

    2012-01-01

    Assessment of the properties of blood-vessel walls by ultrasound radiofrequency (RF)-data technology is an innovative technique. We quantitatively evaluated the intima-media thickness (IMT) and arterial elasticity of the common carotid artery (CCA) in asymptomatic subjects with hypertriglyceridemia (HTG) using RF-data technology. Thirty HTG subjects and 30 matched controls were enrolled in the study. The common carotid arterial systolic diameter, diastolic diameter, IMT, carotid distensibility (CD), local pulse wave velocity (PWVβ), and stiffness (β) were compared between the two groups, as was the correlation between triglyceride level and the parameters mentioned above. The HTG group had significantly higher values of CCA-IMT compared with the control group (p 0.05). The level of triglycerides had significant positive correlations with CCA-IMT (r = 0.493, p < 0.001), whereas significant correlations with CD, PWVβ, and β were not observed in the HTG group. Ultrasound RF-data technology can be used to non-invasively and quantitatively detect the change in the structure and function of the CCA in asymptomatic HTG subjects for evaluating preclinical atherosclerosis.

  10. The adventitia layer modulates the arterial wall elastic response to intra-aortic counterpulsation: in vivo studies.

    Science.gov (United States)

    Cabrera-Fischer, Edmundo I; Bia, Daniel; Zócalo, Yanina; Wray, Sandra; Armentano, Ricardo

    2013-12-01

    There is a relationship between the intra-aortic balloon pumping (IABP) benefits and the dynamic behavior of muscular arteries, which is associated with induced changes on the vessel walls through an endothelial-dependent mechanism. The arterial wall elastic behavior is influenced by adventitial function; however, no studies were performed in order to elucidate if this layer plays a role in the changes determined by IABP. Our aim was to quantify acute IABP effects on the mechanical properties of muscular arteries in induced acute heart failure (AHF), before and after adventitia removal. Pressure and diameter were recorded in the iliac arteries (IA) of sheep (n = 7), before and during 1:2 IABP: (i) in control state (CS) with intact IA, (ii) in CS after IA adventitia removal, and (iii) in de-adventitialized IA after AHF. Conduit function, compliance and arterial distensibility were calculated in each state. During CS, IABP resulted in intact IA dilatation and in an increase in conduit function, compliance and distensibility; adventitial removal determined an increase of arterial stiffness with respect to the CS, which decreased when IABP was used; the increase in arterial stiffness observed after adventitia removal was also detected in AHF state; IABP improves conduit function and arterial stiffness in de-adventitialized arteries, both before and during AHF. However, the improvement in these properties was lower than in intact arteries. Before and after AHF induction, the improvements of conduit function and arterial distensibility determined by IABP in intact IA were significantly reduced after adventitia removal. Adventitial layer integrity would be necessary to maximize IABP-related beneficial effects on arterial system properties. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  11. Bilateral Internal Carotid Artery Occlusion, External Carotid Artery Stenosis, and Vertebral Artery Kinking: May It Be Asymptomatic?

    Science.gov (United States)

    Fatic, Nikola; Jaffer, Usman; Ivana, Saicic; Gordana, Globarevic-Vukcevic; Markovic, Dragan; Kostic, Dusan; Davidovic, Lazar

    2017-10-01

    The clinical spectrum of internal carotid artery occlusion ranges from being a completely asymptomatic occlusion to a devastating stroke or death. The prevalence of asymptomatic internal carotid artery occlusion is unknown, particularly for bilateral occlusion. The distal branches of the external carotid artery anastomose with distal branches of the internal carotid artery provide important sources of collateral circulation to the brain. Stenosis of the external carotid artery with ipsilateral/bilateral internal occlusion may result in ischemic sequelae. Coiling or kinking of the vertebral artery is a rare morphological entity that is infrequently reported because it remains asymptomatic and has no clinical relevance. Currently, there is little evidence to support management strategies for this disease entity and no official recommendations for asymptomatic bilateral carotid artery occlusion. We present a case of a 62-year-old female with asymptomatic bilateral internal carotid artery occlusion, bilateral external carotid artery stenoses, and bilateral kinking of the vertebral artery at the V2 segment, who has been successfully managed conservatively for over 5 years. An individualized approach to management of patients with bilateral internal carotid artery occlusion, especially in combination with external carotid artery stenosis and elongation malformations of the vertebral artery is key to a successful strategy. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Superselective intra-arterial infusion via the superficial temporal artery and occipital artery for gingival carcinoma of the mandible. Simultaneous catheter placement to the maxillary artery and facial artery

    International Nuclear Information System (INIS)

    Iwai, Toshinori; Mitsudo, Kenji; Fukui, Takafumi

    2009-01-01

    Superselective intra-arterial infusion via the superficial temporal artery (STA) has become useful for oral cancer. Approaching via the occipital artery (OA) enables superselective intra-arterial infusion when catheter placement via the STA is impossible. Therefore, simultaneous catheter placement via the STA and OA is possible. We report a surgical method of simultaneous catheter placement via the STA and OA to achieve retrograde superselective intra-arterial infusion for gingival carcinoma of the mandible. Preoperatively, three-dimensional computed tomography angiography was performed to identify the route of the external carotid artery and branches such as the STA, OA, maxillary artery, and facial artery (FA). Thirteen patients with mandibular gingival cancer underwent catheter placement via the STA and OA under local anesthesia. Catheter placement via the STA and OA was superselectively successful in all the patients. The mean operating time was 150.8 min. Catheter placed to the FA via the OA was dislocated during the treatment in one patient, and so the catheter was replaced. This method is useful to enable superselective intra-arterial chemotherapy to the whole gingival carcinoma of the mandible from the start of treatment compared with approaching via the STA. (author)

  13. Lung volumes, ventricular function and pulmonary arterial flow in children operated on for left-sided congenital diaphragmatic hernia: long-term results

    International Nuclear Information System (INIS)

    Abolmaali, Nasreddin; Koch, Arne; Goetzelt, Knut; Vogelberg, Christian; Hahn, Gabriele; Fitze, Guido

    2010-01-01

    To compare MRI-based functional pulmonary and cardiac measurements in the long-term follow-up of children operated on for left-sided congenital diaphragmatic hernia (CDH) with age- and body size-matched healthy controls. Twelve children who received immediate postnatal surgery for closure of isolated left-sided CDH were included and received basic medical examinations, pulmonary function testing and echocardiography. MRI included measurement of lung volume, ventricular function assessment and velocity-encoded imaging of the pulmonary arteries and was compared with the data for 12 healthy children matched for age and body size. While patients' clinical test results were not suspicious, comparison between the MRI data for patients and those for healthy controls revealed significant differences. In patients, the volumes of the left lungs were increased and the tidal volume was larger on the right side. While the stroke volumes of both ventricles were reduced, heart rate and ejection fraction were increased. Flow, acceleration time and cross-sectional area of the left pulmonary artery were reduced. Functional MRI detected pulmonary and cardiac findings in the late follow-up of CDH children which may be missed by standard clinical methods and might be relevant for decisions regarding late outcome and treatment. (orig.)

  14. Lung volumes, ventricular function and pulmonary arterial flow in children operated on for left-sided congenital diaphragmatic hernia: long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Abolmaali, Nasreddin; Koch, Arne [Dresden University of Technology, OncoRay - Molecular and Biological Imaging, Medical Faculty Carl Gustav Carus, Dresden (Germany); Goetzelt, Knut; Vogelberg, Christian [University Clinics Carl Gustav Carus, Dresden University of Technology, Clinic and Policlinic for Pediatrics - Pediatric Pulmonology, Dresden (Germany); Hahn, Gabriele [University Clinics Carl Gustav Carus, Dresden University of Technology, Institute and Policlinic for Radiology - Pediatric Radiology, Dresden (Germany); Fitze, Guido [University Clinics Carl Gustav Carus, Dresden University of Technology, Clinic and Policlinic for Pediatric Surgery, Dresden (Germany)

    2010-07-15

    To compare MRI-based functional pulmonary and cardiac measurements in the long-term follow-up of children operated on for left-sided congenital diaphragmatic hernia (CDH) with age- and body size-matched healthy controls. Twelve children who received immediate postnatal surgery for closure of isolated left-sided CDH were included and received basic medical examinations, pulmonary function testing and echocardiography. MRI included measurement of lung volume, ventricular function assessment and velocity-encoded imaging of the pulmonary arteries and was compared with the data for 12 healthy children matched for age and body size. While patients' clinical test results were not suspicious, comparison between the MRI data for patients and those for healthy controls revealed significant differences. In patients, the volumes of the left lungs were increased and the tidal volume was larger on the right side. While the stroke volumes of both ventricles were reduced, heart rate and ejection fraction were increased. Flow, acceleration time and cross-sectional area of the left pulmonary artery were reduced. Functional MRI detected pulmonary and cardiac findings in the late follow-up of CDH children which may be missed by standard clinical methods and might be relevant for decisions regarding late outcome and treatment. (orig.)

  15. Lung volumes, ventricular function and pulmonary arterial flow in children operated on for left-sided congenital diaphragmatic hernia: long-term results.

    Science.gov (United States)

    Abolmaali, Nasreddin; Koch, Arne; Götzelt, Knut; Hahn, Gabriele; Fitze, Guido; Vogelberg, Christian

    2010-07-01

    To compare MRI-based functional pulmonary and cardiac measurements in the long-term follow-up of children operated on for left-sided congenital diaphragmatic hernia (CDH) with age- and body size-matched healthy controls. Twelve children who received immediate postnatal surgery for closure of isolated left-sided CDH were included and received basic medical examinations, pulmonary function testing and echocardiography. MRI included measurement of lung volume, ventricular function assessment and velocity-encoded imaging of the pulmonary arteries and was compared with the data for 12 healthy children matched for age and body size. While patients' clinical test results were not suspicious, comparison between the MRI data for patients and those for healthy controls revealed significant differences. In patients, the volumes of the left lungs were increased and the tidal volume was larger on the right side. While the stroke volumes of both ventricles were reduced, heart rate and ejection fraction were increased. Flow, acceleration time and cross-sectional area of the left pulmonary artery were reduced. Functional MRI detected pulmonary and cardiac findings in the late follow-up of CDH children which may be missed by standard clinical methods and might be relevant for decisions regarding late outcome and treatment.

  16. The human motor neuron pools receive a dominant slow‐varying common synaptic input

    Science.gov (United States)

    Negro, Francesco; Yavuz, Utku Şükrü

    2016-01-01

    Key points Motor neurons in a pool receive both common and independent synaptic inputs, although the proportion and role of their common synaptic input is debated.Classic correlation techniques between motor unit spike trains do not measure the absolute proportion of common input and have limitations as a result of the non‐linearity of motor neurons.We propose a method that for the first time allows an accurate quantification of the absolute proportion of low frequency common synaptic input (60%) of common input, irrespective of their different functional and control properties.These results increase our knowledge about the role of common and independent input to motor neurons in force control. Abstract Motor neurons receive both common and independent synaptic inputs. This observation is classically based on the presence of a significant correlation between pairs of motor unit spike trains. The functional significance of different relative proportions of common input across muscles, individuals and conditions is still debated. One of the limitations in our understanding of correlated input to motor neurons is that it has not been possible so far to quantify the absolute proportion of common input with respect to the total synaptic input received by the motor neurons. Indeed, correlation measures of pairs of output spike trains only allow for relative comparisons. In the present study, we report for the first time an approach for measuring the proportion of common input in the low frequency bandwidth (60%) proportion of common low frequency oscillations with respect to their total synaptic input. These results suggest that the central nervous system provides a large amount of common input to motor neuron pools, in a similar way to that for muscles with different functional and control properties. PMID:27151459

  17. Arterial wave intensity and ventricular-arterial coupling by vascular ultrasound: rationale and methods for the automated analysis of forwards and backwards running waves.

    Science.gov (United States)

    Rakebrandt, F; Palombo, C; Swampillai, J; Schön, F; Donald, A; Kozàkovà, M; Kato, K; Fraser, A G

    2009-02-01

    Wave intensity (WI) in the circulation is estimated noninvasively as the product of instantaneous changes in pressure and velocity. We recorded diameter as a surrogate for pressure, and velocity in the right common carotid artery using an Aloka SSD-5500 ultrasound scanner. We developed automated software, applying the water hammer equation to obtain local wave speed from the slope of a pressure/velocity loop during early systole to separate net WI into individual forwards and backwards-running waves. A quality index was developed to test for noisy data. The timing, duration, peak amplitude and net energy of separated WI components were measured in healthy subjects with a wide age range. Age and arterial stiffness were independent predictors of local wave speed, whereas backwards-travelling waves correlated more strongly with ventricular systolic function than with age-related changes in arterial stiffness. Separated WI offers detailed insight into ventricular-arterial interactions that may be useful for assessing the relative contributions of ventricular and vascular function to wave travel.

  18. Transcatheter Arterial Infusion of Autologous CD133+ Cells for Diabetic Peripheral Artery Disease

    Directory of Open Access Journals (Sweden)

    Xiaoping Zhang

    2016-01-01

    Full Text Available Microvascular lesion in diabetic peripheral arterial disease (PAD still cannot be resolved by current surgical and interventional technique. Endothelial cells have the therapeutic potential to cure microvascular lesion. To evaluate the efficacy and immune-regulatory impact of intra-arterial infusion of autologous CD133+ cells, we recruited 53 patients with diabetic PAD (27 of CD133+ group and 26 of control group. CD133+ cells enriched from patients’ PB-MNCs were reinfused intra-arterially. The ulcer healing followed up till 18 months was 100% (3/3 in CD133+ group and 60% (3/5 in control group. The amputation rate was 0 (0/27 in CD133+ group and 11.54% (3/26 in control group. Compared with the control group, TcPO2 and ABI showed obvious improvement at 18 months and significant increasing VEGF and decreasing IL-6 level in the CD133+ group within 4 weeks. A reducing trend of proangiogenesis and anti-inflammatory regulation function at 4 weeks after the cells infusion was also found. These results indicated that autologous CD133+ cell treatment can effectively improve the perfusion of morbid limb and exert proangiogenesis and anti-inflammatory immune-regulatory impacts by paracrine on tissue microenvironment. The CD133+ progenitor cell therapy may be repeated at a fixed interval according to cell life span and immune-regulatory function.

  19. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  20. [Cognitive disturbances in patients with arterial hypertension].

    Science.gov (United States)

    Starchina, Iu A; Parfenov, V A; Chazova, I E; Pustovitova, T S; Iakhno, N N

    2008-01-01

    Memory impairment, headaches and vertigo are considered as initial appearances of chronic cerebral vascular disorder in patients with arterial hypertension (AH). The complex analysis of complaints, cognitive functioning, emotional state and MRI data was conducted in 60 patients with AH, mean age 58,4+/-7,8 years, without a history of stroke and 30 controls matched for age, sex and education. Impairment of cognitive functioning was assessed by the Psychiatric Status Scale (a short version), the Clock Drawing Test, tests of auditory and verbal memory, attention concentration, speed of test performance, speech fluency and spatial orientation. The deterioration effect of systolic arterial pressure on cognitive functioning was found. The lesions of white matter (subcortical and/or periventricular leucoaraiosis) were observed in 76% of patients and single asymptomatic lacunar infarctions--in 20%. Cerebral vascular lesions were correlated with cognitive impairment. Anxiety and anxiety-depressive disorders which were not associated with the cerebral vascular lesion but related in large to the patient's complaints on headaches and vertigo were revealed in 62% of cases. The results of the study suggest that cognitive dysfunction proves to be the early and reliable predictor of chronic cerebral vascular disorder in patients with arterial hypertension.

  1. Evaluation of factor for one-point venous blood sampling method based on the causality model

    International Nuclear Information System (INIS)

    Matsutomo, Norikazu; Onishi, Hideo; Kobara, Kouichi; Sasaki, Fumie; Watanabe, Haruo; Nagaki, Akio; Mimura, Hiroaki

    2009-01-01

    One-point venous blood sampling method (Mimura, et al.) can evaluate the regional cerebral blood flow (rCBF) value with a high degree of accuracy. However, the method is accompanied by complexity of technique because it requires a venous blood Octanol value, and its accuracy is affected by factors of input function. Therefore, we evaluated the factors that are used for input function to determine the accuracy input function and simplify the technique. The input function which uses the time-dependent brain count of 5 minutes, 15 minutes, and 25 minutes from administration, and the input function in which an objective variable is used as the artery octanol value to exclude the venous blood octanol value are created. Therefore, a correlation between these functions and rCBF value by the microsphere (MS) method is evaluated. Creation of a high-accuracy input function and simplification of technique are possible. The rCBF value obtained by the input function, the factor of which is a time-dependent brain count of 5 minutes from administration, and the objective variable is artery octanol value, had a high correlation with the MS method (y=0.899x+4.653, r=0.842). (author)

  2. Systemic Arterial-to-Pulmonary Artery Shunt Utilization

    African Journals Online (AJOL)

    multiruka1

    In certain circumstances, such as cyanotic neonates with tetralogy of Fallot (4) or cyanotic patients with. Tetralogy of Fallot and hypoplastic pulmonary arteries. (5), better outcomes are obtained if definitive surgery. (total correction or palliation) is preceded by creation of a systemic arterial-to-pulmonary artery shunt (SAPAS).

  3. Stochastic weather inputs for improved urban water demand forecasting: application of nonlinear input variable selection and machine learning methods

    Science.gov (United States)

    Quilty, J.; Adamowski, J. F.

    2015-12-01

    Urban water supply systems are often stressed during seasonal outdoor water use as water demands related to the climate are variable in nature making it difficult to optimize the operation of the water supply system. Urban water demand forecasts (UWD) failing to include meteorological conditions as inputs to the forecast model may produce poor forecasts as they cannot account for the increase/decrease in demand related to meteorological conditions. Meteorological records stochastically simulated into the future can be used as inputs to data-driven UWD forecasts generally resulting in improved forecast accuracy. This study aims to produce data-driven UWD forecasts for two different Canadian water utilities (Montreal and Victoria) using machine learning methods by first selecting historical UWD and meteorological records derived from a stochastic weather generator using nonlinear input variable selection. The nonlinear input variable selection methods considered in this work are derived from the concept of conditional mutual information, a nonlinear dependency measure based on (multivariate) probability density functions and accounts for relevancy, conditional relevancy, and redundancy from a potential set of input variables. The results of our study indicate that stochastic weather inputs can improve UWD forecast accuracy for the two sites considered in this work. Nonlinear input variable selection is suggested as a means to identify which meteorological conditions should be utilized in the forecast.

  4. Carotid artery stiffness evaluated early by wave intensity in normal left ventricular function in post-radiotherapy patients with nasopharyngeal carcinoma.

    Science.gov (United States)

    Zhang, Zhuo; Luo, Runlan; Tan, Bijun; Qian, Jing; Duan, Yanfang; Wang, Nan; Li, Guangsen

    2018-04-01

    This study aims to assess carotid elasticity early in normal left ventricular function in post-radiotherapy patients with nasopharyngeal carcinoma (NPC) by wave intensity. Sixty-seven post-radiotherapy patients all with normal left ventricular function were classified into group NPC1 and group NPC2 based on their carotid intima-media thickness. Thirty age- and sex-matched NPC patients without any history of irradiation and chemotherapy were included as a control group. Carotid parameters, including stiffness constant (β), pressure-strain elastic modulus (Ep), arterial compliance (AC), stiffness constant pulse wave velocity (PWVβ), and wave intensity pulse wave velocity (PWVWI) were measured. There were no significant differences in conventional echocardiographic variables among the three groups. In comparison with the control group, β, Ep, PWVβ, and PWVWI were significantly increased, while AC was significantly decreased in the NPC1 and NPC2 groups, and there were differences between the NPC1 group and NPC2 group (all P < 0.05). This study suggested that carotid artery stiffness increased with reduced carotid compliance in post-RT with NPC.

  5. Dynamic PET of human liver inflammation: impact of kinetic modeling with optimization-derived dual-blood input function.

    Science.gov (United States)

    Wang, Guobao; Corwin, Michael T; Olson, Kristin A; Badawi, Ramsey D; Sarkar, Souvik

    2018-05-30

    The hallmark of nonalcoholic steatohepatitis is hepatocellular inflammation and injury in the setting of hepatic steatosis. Recent work has indicated that dynamic 18F-FDG PET with kinetic modeling has the potential to assess hepatic inflammation noninvasively, while static FDG-PET did not show a promise. Because the liver has dual blood supplies, kinetic modeling of dynamic liver PET data is challenging in human studies. The objective of this study is to evaluate and identify a dual-input kinetic modeling approach for dynamic FDG-PET of human liver inflammation. Fourteen human patients with nonalcoholic fatty liver disease were included in the study. Each patient underwent one-hour dynamic FDG-PET/CT scan and had liver biopsy within six weeks. Three models were tested for kinetic analysis: traditional two-tissue compartmental model with an image-derived single-blood input function (SBIF), model with population-based dual-blood input function (DBIF), and modified model with optimization-derived DBIF through a joint estimation framework. The three models were compared using Akaike information criterion (AIC), F test and histopathologic inflammation reference. The results showed that the optimization-derived DBIF model improved the fitting of liver time activity curves and achieved lower AIC values and higher F values than the SBIF and population-based DBIF models in all patients. The optimization-derived model significantly increased FDG K1 estimates by 101% and 27% as compared with traditional SBIF and population-based DBIF. K1 by the optimization-derived model was significantly associated with histopathologic grades of liver inflammation while the other two models did not provide a statistical significance. In conclusion, modeling of DBIF is critical for kinetic analysis of dynamic liver FDG-PET data in human studies. The optimization-derived DBIF model is more appropriate than SBIF and population-based DBIF for dynamic FDG-PET of liver inflammation. © 2018

  6. Relation of epicardial adipose tissue with arterial compliance and stiffness in patients with hypertension.

    Science.gov (United States)

    Korkmaz, Levent; Cirakoglu, Omer Faruk; Ağaç, Mustafa Tarik; Erkan, Hakan; Korkmaz, Ayca Ata; Acar, Zeydin; Kul, Selim; Hatem, Engin; Çelik, Şükrü

    2014-09-01

    The main aim of the present study was to investigate the association between epicardial adipose tissue (EAT) and arterial function in patients with asymptomatic hypertension. Patients with hypertension (n = 155) were enrolled consecutively. Patients with decreased arterial compliance (AC) and increased cardioankle vascular index (CAVI) had higher EAT values compared with those with normal AC and CAVI (6.23 ± 1.67 vs 4.91 ± 1.40, P arterial function in patients with asymptomatic hypertension. The link between EAT and arterial stiffness deserves further investigation. © The Author(s) 2013.

  7. Proximal Versus Distal Splenic Artery Embolisation for Blunt Splenic Trauma: What is the Impact on Splenic Immune Function?

    International Nuclear Information System (INIS)

    Foley, P. T.; Kavnoudias, H.; Cameron, P. U.; Czarnecki, C.; Paul, E.; Lyon, S. M.

    2015-01-01

    PurposeTo compare the impact of proximal or distal splenic artery embolisation versus that of splenectomy on splenic immune function as measured by IgM memory B cell levels.Materials and MethodsPatients with splenic trauma who were treated by splenic artery embolisation (SAE) were enrolled. After 6 months splenic volume was assessed by CT, and IgM memory B cells in peripheral blood were measured and compared to a local normal reference population and to a post-splenectomy population.ResultsOf the 71 patients who underwent embolisation, 38 underwent proximal embolisation, 11 underwent distal embolisation, 22 patients were excluded, 1 had both proximal and distal embolisation, 5 did not survive and 16 did not return for evaluation. There was a significant difference between splenectomy and proximal or distal embolisation and a trend towards greater preservation of IgM memory B cell number in those with distal embolisation—a difference that could not be attributed to differences in age, grade of injury or residual splenic volume.ConclusionIgM memory B cell levels are significantly higher in those treated with SAE compared to splenectomy. Our data provide evidence that splenic embolisation should reduce immunological complications of spleen trauma and suggest that distal embolisation may maintain better function

  8. Proximal Versus Distal Splenic Artery Embolisation for Blunt Splenic Trauma: What is the Impact on Splenic Immune Function?

    Energy Technology Data Exchange (ETDEWEB)

    Foley, P. T., E-mail: pfoley@doctors.org.uk [The Canberra Hospital, Department of Medical Imaging (Australia); Kavnoudias, H., E-mail: h.kavnoudias@alfred.org.au [The Alfred Hospital, Radiology Research Unit, Radiology Department (Australia); Cameron, P. U., E-mail: paul.cameron@unimelb.edu.au [The Alfred Hospital, Infectious Diseases Unit (Australia); Czarnecki, C., E-mail: caroline.czarnecki@gmail.com [Royal Melbourne Hospital, Radiology Department (Australia); Paul, E., E-mail: eldho.paul@monash.edu [Monash University, Department of Epidemiology & Preventive Medicine, School of Public Health and Preventive Medicine, Alfred Hospital (Australia); Lyon, S. M., E-mail: lyonsey@optusnet.com.au [Melbourne Endovascular (Australia)

    2015-10-15

    PurposeTo compare the impact of proximal or distal splenic artery embolisation versus that of splenectomy on splenic immune function as measured by IgM memory B cell levels.Materials and MethodsPatients with splenic trauma who were treated by splenic artery embolisation (SAE) were enrolled. After 6 months splenic volume was assessed by CT, and IgM memory B cells in peripheral blood were measured and compared to a local normal reference population and to a post-splenectomy population.ResultsOf the 71 patients who underwent embolisation, 38 underwent proximal embolisation, 11 underwent distal embolisation, 22 patients were excluded, 1 had both proximal and distal embolisation, 5 did not survive and 16 did not return for evaluation. There was a significant difference between splenectomy and proximal or distal embolisation and a trend towards greater preservation of IgM memory B cell number in those with distal embolisation—a difference that could not be attributed to differences in age, grade of injury or residual splenic volume.ConclusionIgM memory B cell levels are significantly higher in those treated with SAE compared to splenectomy. Our data provide evidence that splenic embolisation should reduce immunological complications of spleen trauma and suggest that distal embolisation may maintain better function.

  9. Proximal Versus Distal Splenic Artery Embolisation for Blunt Splenic Trauma: What is the Impact on Splenic Immune Function?

    Science.gov (United States)

    Foley, P T; Kavnoudias, H; Cameron, P U; Czarnecki, C; Paul, E; Lyon, S M

    2015-10-01

    To compare the impact of proximal or distal splenic artery embolisation versus that of splenectomy on splenic immune function as measured by IgM memory B cell levels. Patients with splenic trauma who were treated by splenic artery embolisation (SAE) were enrolled. After 6 months splenic volume was assessed by CT, and IgM memory B cells in peripheral blood were measured and compared to a local normal reference population and to a post-splenectomy population. Of the 71 patients who underwent embolisation, 38 underwent proximal embolisation, 11 underwent distal embolisation, 22 patients were excluded, 1 had both proximal and distal embolisation, 5 did not survive and 16 did not return for evaluation. There was a significant difference between splenectomy and proximal or distal embolisation and a trend towards greater preservation of IgM memory B cell number in those with distal embolisation-a difference that could not be attributed to differences in age, grade of injury or residual splenic volume. IgM memory B cell levels are significantly higher in those treated with SAE compared to splenectomy. Our data provide evidence that splenic embolisation should reduce immunological complications of spleen trauma and suggest that distal embolisation may maintain better function.

  10. Impact of hypertension severity on arterial stiffness, cerebral vasoreactivity, and cognitive performance

    Science.gov (United States)

    Muela, Henrique Cotchi Simbo; Costa-Hong, Valeria A.; Yassuda, Monica Sanches; Machado, Michel Ferreira; Nogueira, Ricardo de Carvalho; Moraes, Natalia C.; Memória, Claudia Maia; Macedo, Thiago A.; Bor-Seng-Shu, Edson; Massaro, Ayrton Roberto; Nitrini, Ricardo; Bortolotto, Luiz A.

    2017-01-01

    ABSTRACT. Aging, hypertension (HTN), and other cardiovascular risk factors contribute to structural and functional changes of the arterial wall. Objective: To evaluate whether arterial stiffness (AS) is related to cerebral blood flow changes and its association with cognitive function in patients with hypertension. Methods: 211 patients (69 normotensive and 142 hypertensive) were included. Patients with hypertension were divided into 2 stages: HTN stage-1 and HTN stage-2. The mini-mental state examination (MMSE), Montreal Cognitive Assessment (MoCA) and a battery of neuropsychological (NPE) tests were used to determine cognitive function. Pulse wave velocity was measured using the Complior®. Carotid properties were assessed by radiofrequency ultrasound. Central arterial pressure and augmentation index were obtained using applanation tonometry. Middle cerebral artery flow velocity was measured by transcranial Doppler ultrasonography. Results: Both arterial stiffness parameters and cerebral vasoreactivity worsened in line with HTN severity. There was a negative correlation between breath holding index (BHI) and arterial stiffness parameters. Cognitive performance worsened in line with HTN severity, with statistical difference occurring mainly between the HTN-2 and normotension groups on both the MMSE and MoCA. The same tendency was observed on the NPE tests. Conclusion: Hypertension severity was associated with higher AS, worse BHI, and lower cognitive performance. PMID:29354219

  11. Uterine artery chemoembolization: its application in treating cervical pregnancy

    International Nuclear Information System (INIS)

    Zhang Guofu; Shang Mingyi; Tian Xiaomei; Han Zhigang; Wang Xuezhen; Wang Dongyan; Huang Zirong; Xu Congjian

    2009-01-01

    Objective: To discuss the feasibility and safety of uterine artery chemoembolization in the treatment of cervical pregnancy. Methods: During the period of Sep. 2005-Dec. 2007, uterine artery chemoemboliztion was performed in 12 patients with cervical pregnancy in the authors' hospital. Via bilateral uterine arteries 100 mg MTX and 80,000 U Gentamycin were infused separately, after that the bilateral uterine arteries were embolized with gelfoam. Cleaning of the uterus and the cervix uteri was carried out in 24 -72 h after the procedure. Results: The technical success rate of bilateral uterine artery chemoembolization was 100%. The blood loss was 50-100 ml (mean 65 ml) during the procedure of cleaning the uterus and the cervix uteri. No serious complications occurred. Conclusion: Uterine artery chemoembolization is an effective and safe treatment for cervical pregnancy, which can greatly avoid unnecessary uterectomy and preserve fertility function. (authors)

  12. The Influence of Prosodic Input in the Second Language Classroom: Does It Stimulate Child Acquisition of Word Order and Function Words?

    Science.gov (United States)

    Campfield, Dorota E.; Murphy, Victoria A.

    2017-01-01

    This paper reports on an intervention study with young Polish beginners (mean age: 8 years, 3 months) learning English at school. It seeks to identify whether exposure to rhythmic input improves knowledge of word order and function words. The "prosodic bootstrapping hypothesis", relevant in developmental psycholinguistics, provided the…

  13. An unusual neonatal presentation of anomalous origin of the left coronary artery arising from the pulmonary artery.

    Science.gov (United States)

    Garty, Y; Guri, A; Shinwell, E S; Matitiau, A

    2008-01-01

    We describe a previously unreported neonatal presentation of an anomalous origin of the left coronary artery arising from the pulmonary artery. This is a full-term female infant after normal pregnancy and delivery. The baby was diagnosed at 2 days of age due to weak femoral pulses noted on the routine nursery discharge examination. The cardiac examination revealed weak pulses everywhere and mild tachypnea and tachycardia. An electrocardiogram showed clear signs of ischemia. Echocardiography demonstrated an anomalous origin of the left coronary artery arising from the pulmonary artery with bidirectional blood flow. There was a severely depressed left ventricular function and mild mitral valve regurgitation. At 4 days of age, the infant underwent complete successful surgical repair with reimplantation of the anomalous coronary artery to the aorta. She recovered slowly but well. Fifteen months later she is doing well with no cardiac residua. A neonatal presentation is very unusual due to protective high pulmonary resistance after birth, with gradual decline in pressure and gradual onset of heart failure. This case may be related to an unusually rapid drop in pulmonary vascular resistance causing very early cardiac ischemia. (c) 2007 S. Karger AG, Basel.

  14. Unusual Survival of Anomalous Left Coronary Artery From the Pulmonary Artery With Severe Rheumatic Mitral Stenosis in Septuagenarian Women: Foes Becoming Friends?

    Science.gov (United States)

    Sinha, Santosh Kumar; Khanra, Dibbendhu; Jha, Mukesh Jitendra; Singh, Karandeep; Razi, Mahamdulla; Goel, Amit; Mishra, Vikas; Asif, Mohammad; Sachan, Mohit; Afdaali, Nasar; Kumar, Ashutosh; Thakur, Ramesh; Krishna, Vinay; Pandey, Umeshwar; Varma, Chandra Mohan

    2016-10-01

    ALCAPA syndrome (anomalous origin of the left coronary artery from the pulmonary artery) is a rare disease but lethal with clinical expression from myocardial infarction, congestive heart failure to death during early infancy and unusual survival to adulthood. We report a 73-year-old woman with ALCAPA who presented with exertional dyspnea (NYHA functional class II) over past 2 years. Physical examination revealed soft S, long mid diastolic rumbling murmur and apical pan-systolic murmur. Electrocardiography displayed biatrial enlargement and poor R progression and normal sinus rhythm. Echocardiography established calcified severe mitral stenosis (MS), presence of continuous flow entering the pulmonary trunk, turbulent continuous flow in inter-ventricular septum with left to right shunt in contrast echocardiography and normal systolic function. Coronary angiogram showed absence of left coronary artery (LCA) originating from aorta, dilated and tortuous right coronary artery (RCA) and abundant Rentrop grade 3 intercoronary collateral communicating with LCA originating from pulmonary trunk which was also confirmed on coronary CT angiogram thus establishing diagnosis of ALCAPA. It is exceedingly rare to be associated with severe MS. However, such a long survival in our patient can be explained by the severe pulmonary arterial hypertension which may be contributing to lesser coronary steal.

  15. Maternal Arterial Murmur in Pregnancy

    DEFF Research Database (Denmark)

    Riknagel, Diana

    2017-01-01

    Alternative methods of assessing the placental function are called for in the attempt to clarify the pathophysiology behind adverse pregnancy outcome as fetal growth restriction. A new concept of using cardiovascular sounds emitted near the uterine arteries in pregnancy is investigated...

  16. TEVAR and covering the celiac artery. Is it safe or not?

    DEFF Research Database (Denmark)

    Falkenberg, Morten; Lönn, Lars Birger; Schroeder, Torben Veith

    2010-01-01

    artery. In the latter case, adequate collateral supply to the upper gastrointestinal tract is crucial. Collateral arteries joining the celiac and the superior mesenteric arteries are well characterized in patients with chronic celiac stenosis or occlusion. Are these collateral pathways sufficient also...... for sudden iatrogenic closure of the celiac artery? By performing a preoperative angiography of the superior mesenteric artery with temporary balloon occlusion of the celiac artery, collateral capacity between the two vessels can be tested in advance. Exact positioning of the distal end of a large thoracic...... together, in the large majority of patients, it appears that intentional celiac coverage can be done safely provided that sufficient collateral function have been demonstrated in advance....

  17. Left coronary arterial blood flow: Noninvasive detection by Doppler US

    International Nuclear Information System (INIS)

    Gramiak, R.; Holen, J.; Moss, A.J.; Gutierrez, O.H.; Picone, A.L.; Roe, S.A.

    1986-01-01

    Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left coronary artery can be distinguished by its blood flow toward the cardiac apex and by specific, functional flow features. Flow patterns vary among the left main, circumflex, and anterior descending arteries; patterns also vary with respiration cycles. In the present study, coronary arterial blood flow was detected in 58 of 70 patients (83%). Findings were validated by selectively injecting an agitated saline contrast medium into the left coronary artery and, in another study, by comparing human Doppler phasic flow waveforms with electromagnetic flowmeter recordings obtained in dogs

  18. Testicular artery arising from an aberrant right renal artery | Suluba ...

    African Journals Online (AJOL)

    This case report we discovered the rare variation of the origin of the right testicular artery arising from the right aberrant renal artery with double renal artery irrigating both left and right kidneys. These variations in the testicular arteries and renal arteries have implication to surgical procedures such as orchidopexy repair for ...

  19. Jointness through vessel capacity input in a multispecies fishery

    DEFF Research Database (Denmark)

    Hansen, Lars Gårn; Jensen, Carsten Lynge

    2014-01-01

    capacity. We develop a fixed but allocatable input model of purse seine fisheries capturing this particular type of jointness. We estimate the model for the Norwegian purse seine fishery and find that it is characterized by nonjointness, while estimations for this fishery using the standard models imply...... are typically modeled as either independent single species fisheries or using standard multispecies functional forms characterized by jointness in inputs. We argue that production of each species is essentially independent but that jointness may be caused by competition for fixed but allocable input of vessel...

  20. Inflammatory processes during arteriogenesis : the contribution of the innate immune system to collateral artery growth

    NARCIS (Netherlands)

    de Groot, D.

    2011-01-01

    The central theme of the work presented in the thesis is restoration of tissue perfusion by collateral artery growth. During collateral artery growth, or arteriogenesis, unused pre-existing vascular anastomoses remodel into functional arteries. These arteries are able to take over the perfusion of

  1. Long-term diet-induced hypertension in rats is associated with reduced expression and function of small artery SKCa, IKCa, and Kir2.1 channels

    DEFF Research Database (Denmark)

    Gradel, Anna Katrina Jógvansdóttir; Salomonsson, Max; Sørensen, Charlotte Mehlin

    2018-01-01

    in long-term diet-induced hypertension in rats. Hypothesis: A 28-week diet rich in fat, fructose, or both, will lead to changes in K+ transporter expression and function, which is associated with increased blood pressure and decreased arterial function. Methods and Results: Male Sprague Dawley rats......RNA expression of vascular K+ transporters, and vessel myography in small mesenteric arteries. BW was increased in the High Fat and High Fat/Fruc groups, and SBP was increased in the High Fat/Fruc group. mRNA expression of SKCa, IKCa, and Kir2.1 K+ channels were reduced in the High Fat/Fruc group. Reduced EDH......-type relaxation to acetylcholine was seen in the High Fat and High Fat/Fruc groups. Ba2+-sensitive dilatation to extracellular K+ was impaired in all experimental diet groups. Conclusions: Reduced expression and function of SKCa, IKCa and Kir2.1 channels is associated with elevated blood pressure in rats fed...

  2. Monocytic microRNA profile associated with coronary collateral artery function in chronic total occlusion patients.

    Science.gov (United States)

    Hakimzadeh, Nazanin; Elias, Joëlle; Wijntjens, Gilbert W M; Theunissen, Ruud; van Weert, Angela; Smulders, Martijn W; van den Akker, Nynke; Moerland, Perry D; Verberne, Hein J; Hoebers, Loes P; Henriques, Jose P S; van der Laan, Anja M; Ilhan, Mustafa; Post, Mark; Bekkers, Sebastiaan C A M; Piek, Jan J

    2017-05-08

    An expansive collateral artery network is correlated with improved survival in case of adverse cardiac episodes. We aimed to identify cellular microRNAs (miRNA; miR) important for collateral artery growth. Chronic total occlusion (CTO) patients (n = 26) were dichotomized using pressure-derived collateral flow index (CFI p ) measurements; high collateral capacity (CFI p  > 0.39; n = 14) and low collateral (CFI p  collateral capacity patients. Validation by real-time polymerase chain reaction demonstrated significantly decreased expression of miR339-5p in all stimulated monocyte phenotypes of low collateral capacity patients. MiR339-5p showed significant correlation with CFI p values in stimulated monocytes. Ingenuity pathway analysis of predicted gene targets of miR339-5p and differential gene expression data from high versus low CFI p patients (n = 20), revealed significant association with STAT3 pathway, and also suggested a possible regulatory role for this signaling pathway. These results identify a novel association between miR339-5p and coronary collateral function. Future work examining modulation of miR339-5p and downstream effects on the STAT3 pathway and subsequent collateral vessel growth are warranted.

  3. Pulmonary Arterial Hypertension and Neonatal Arterial Switch Surgery for Correction of Transposition of the Great Arteries.

    Science.gov (United States)

    Domínguez Manzano, Paula; Mendoza Soto, Alberto; Román Barba, Violeta; Moreno Galdó, Antonio; Galindo Izquierdo, Alberto

    2016-09-01

    There are few reports of the appearance of pulmonary arterial hypertension following arterial switch surgery in the neonatal period to correct transposition of the great arteries. We assessed the frequency and clinical pattern of this complication in our series of patients. Our database was reviewed to select patients with transposition of the great arteries corrected by neonatal arterial switch at our hospital and who developed pulmonary hypertension over time. We identified 2 (1.3%) patients with transposition of the great arteries successfully repaired in the first week of life who later experienced pulmonary arterial hypertension. The first patient was a 7-year-old girl diagnosed with severe pulmonary hypertension at age 8 months who did not respond to medical treatment and required lung transplantation. The anatomic pathology findings were consistent with severe pulmonary arterial hypertension. The second patient was a 24-month-old boy diagnosed with severe pulmonary hypertension at age 13 months who did not respond to medical therapy. Pulmonary hypertension is a rare but very severe complication that should be investigated in all patients with transposition of the great arteries who have undergone neonatal arterial switch, in order to start early aggressive therapy for affected patients, given the poor therapeutic response and poor prognosis involved. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  4. Competition and convergence between auditory and cross-modal visual inputs to primary auditory cortical areas

    Science.gov (United States)

    Mao, Yu-Ting; Hua, Tian-Miao

    2011-01-01

    Sensory neocortex is capable of considerable plasticity after sensory deprivation or damage to input pathways, especially early in development. Although plasticity can often be restorative, sometimes novel, ectopic inputs invade the affected cortical area. Invading inputs from other sensory modalities may compromise the original function or even take over, imposing a new function and preventing recovery. Using ferrets whose retinal axons were rerouted into auditory thalamus at birth, we were able to examine the effect of varying the degree of ectopic, cross-modal input on reorganization of developing auditory cortex. In particular, we assayed whether the invading visual inputs and the existing auditory inputs competed for or shared postsynaptic targets and whether the convergence of input modalities would induce multisensory processing. We demonstrate that although the cross-modal inputs create new visual neurons in auditory cortex, some auditory processing remains. The degree of damage to auditory input to the medial geniculate nucleus was directly related to the proportion of visual neurons in auditory cortex, suggesting that the visual and residual auditory inputs compete for cortical territory. Visual neurons were not segregated from auditory neurons but shared target space even on individual target cells, substantially increasing the proportion of multisensory neurons. Thus spatial convergence of visual and auditory input modalities may be sufficient to expand multisensory representations. Together these findings argue that early, patterned visual activity does not drive segregation of visual and auditory afferents and suggest that auditory function might be compromised by converging visual inputs. These results indicate possible ways in which multisensory cortical areas may form during development and evolution. They also suggest that rehabilitative strategies designed to promote recovery of function after sensory deprivation or damage need to take into

  5. Successful flow reduction surgery for a ruptured true posterior communicating artery aneurysm caused by the common carotid artery ligation for epistaxis.

    Science.gov (United States)

    Yamao, Yukihiro; Takahashi, Jun C; Satow, Tetsu; Iihara, Koji; Miyamoto, Susumu

    2014-01-01

    Carotid artery occlusion can lead to the development of rare true posterior communicating artery (PCoA) aneurysms because of hemodynamic stress on the PCoA. Surgical treatment of these lesions is challenging. The authors report a case of a true PCoA aneurysm that developed and ruptured 37 years after ligation of the ipsilateral common carotid artery for epistaxis. The lesion was successfully treated with clipping of the distal M1 segment of the middle cerebral artery (MCA) after the occipital artery-radial artery free graft-MCA bypass, which led to extreme reduction in collateral flow through the PCoA. A cortical branch, located just proximal to the obliteration site, functioned as a sufficient flow outlet. The aneurysm shrank, and the patient has been doing well without any symptoms for 5 years after surgery. M1 obliteration combined with high-flow extra-intracranial bypass might be a promising option for a true PCoA aneurysm, and therapeutic design that leaves a sufficient flow outlet on the M1 is mandatory to avoid unexpected occlusion of the M1 and its perforators.

  6. Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

    Directory of Open Access Journals (Sweden)

    Shahrbano Shahbazi

    2013-12-01

    Full Text Available Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG. Methods: In 146 patients scheduled for on-pump CABG, the liver function test was done preoperatively and on the first postoperative day. Some preoperative and intraoperative risk factors were checked and then the postoperative liver function tests were compared with the preoperative ones. Probable relationships between these changes and the preoperative and intraoperative risk factors were studied. Results: A medical history of diabetes had a significant relationship with the changes in direct bilirubin. Preoperative central venous pressure had a significant relationship with the changes in aspartate aminotransferase and alanine aminotransferase. Use of intra-aortic balloon pump and duration of aortic cross-clamp were significantly related to the changes in the liver function tests except for alanine aminotransferase and alkaline phosphatase. Conclusion: It seems that the techniques for the reduction of cardiopulmonary bypass and aortic cross-clamp duration may be useful to protect liver function. We recommend that a larger population of patients be studied to confirm these findings.

  7. Analysis of Arterial Mechanics During Head-down Tilt Bed Rest

    Science.gov (United States)

    Elliot, Morgan; Martin, David S.; Westby, Christian M.; Stenger, Michael B.; Platts, Steve

    2014-01-01

    Arterial health may be affected by microgravity or ground based analogs of spaceflight, as shown by an increase in thoracic aorta stiffness1. Head-down tilt bed rest (HDTBR) is often used as a ground-based simulation of spaceflight because it induces physiological changes similar to those that occur in space2, 3. This abstract details an analysis of arterial stiffness (a subclinical measure of atherosclerosis), the distensibility coefficient (DC), and the pressure-strain elastic modulus (PSE) of the arterial walls during HDTBR. This project may help determine how spaceflight differentially affects arterial function in the upper vs. lower body.

  8. Computer model analysis of the radial artery pressure waveform.

    Science.gov (United States)

    Schwid, H A; Taylor, L A; Smith, N T

    1987-10-01

    Simultaneous measurements of aortic and radial artery pressures are reviewed, and a model of the cardiovascular system is presented. The model is based on resonant networks for the aorta and axillo-brachial-radial arterial system. The model chosen is a simple one, in order to make interpretation of the observed relationships clear. Despite its simplicity, the model produces realistic aortic and radial artery pressure waveforms. It demonstrates that the resonant properties of the arterial wall significantly alter the pressure waveform as it is propagated from the aorta to the radial artery. Although the mean and end-diastolic radial pressures are usually accurate estimates of the corresponding aortic pressures, the systolic pressure at the radial artery is often much higher than that of the aorta due to overshoot caused by the resonant behavior of the radial artery. The radial artery dicrotic notch is predominantly dependent on the axillo-brachial-radial arterial wall properties, rather than on the aortic valve or peripheral resistance. Hence the use of the radial artery dicrotic notch as an estimate of end systole is unreliable. The rate of systolic upstroke, dP/dt, of the radial artery waveform is a function of many factors, making it difficult to interpret. The radial artery waveform usually provides accurate estimates for mean and diastolic aortic pressures; for all other measurements it is an inadequate substitute for the aortic pressure waveform. In the presence of low forearm peripheral resistance the mean radial artery pressure may significantly underestimate the mean aortic pressure, as explained by a voltage divider model.

  9. Evaluation of left ventricular myocardial function in patients with coronary artery disease and myocardial dysfunction before and after coronary artery bypass grafting by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Juergens, K.U.; Renger, B.; Reimer, P.; Tombach, B.; Heindel, W.; Wichter, T.; Bruns, H.J.; Vahlhaus, C.; Janssen, F.W.; Breithardt, G.

    2001-01-01

    Purpose: To evaluate left ventricular (LV) myocardial function in ten patients with coronary artery disease (CAD) preoperatively and 6 months after coronary bypass grafting (CABG) by cardiac MRI. Material and methods: Ten patients (mean 65.2±5.9 years) with angiographically proven CAD and an indication for elective CABG underwent prospective evaluation of global LV function and regional wall motion by Cine-MRI at rest using a multiphase FLASH-2D sequence following regions of interest (ROI)-defined diagnostics of regional myocardial wall motion by means of levocardiography. Within the ROIs a total of 613 LV myocardial segments were analyzed preceding and following surgical revascularization. Results were compared with the data of 10 healthy volunteers. Results: Preoperatively, patients showed reduced stroke volume and ejection fraction compared with volunteers (p [de

  10. Indirect Validation of Probe Speed Data on Arterial Corridors

    Energy Technology Data Exchange (ETDEWEB)

    Eshragh, Sepideh [Center for Advanced Transportation Technology, University of Maryland, College Park, 5000 College Avenue, Suite 2206, College Park, MD 20742; Young, Stanley E. [National Renewable Energy Laboratory, 15013 Denver West Parkway, Golden, CO 80401; Sharifi, Elham [Center for Advanced Transportation Technology, University of Maryland, College Park, 5000 College Avenue, Suite 2206, College Park, MD 20742; Hamedi, Masoud [Center for Advanced Transportation Technology, University of Maryland, College Park, 5000 College Avenue, Suite 2206, College Park, MD 20742; Sadabadi, Kaveh Farokhi [Center for Advanced Transportation Technology, University of Maryland, College Park, 5000 College Avenue, Suite 2206, College Park, MD 20742

    2017-01-01

    This study aimed to estimate the accuracy of probe speed data on arterial corridors on the basis of roadway geometric attributes and functional classification. It was assumed that functional class (medium and low) along with other road characteristics (such as weighted average of the annual average daily traffic, average signal density, average access point density, and average speed) were available as correlation factors to estimate the accuracy of probe traffic data. This study tested these factors as predictors of the fidelity of probe traffic data by using the results of an extensive validation exercise. This study showed strong correlations between these geometric attributes and the accuracy of probe data when they were assessed by using average absolute speed error. Linear models were regressed to existing data to estimate appropriate models for medium- and low-type arterial corridors. The proposed models for medium- and low-type arterials were validated further on the basis of the results of a slowdown analysis. These models can be used to predict the accuracy of probe data indirectly in medium and low types of arterial corridors.

  11. An investigation of an autonomic innervation of the vertebral artery using monoamine histofluorescence

    Directory of Open Access Journals (Sweden)

    JA Mitchell

    2009-06-01

    Full Text Available Blood flow to the hindbrain, via the paired vertebral arteries, must be uncompromised for adequate neurological functioning of its vital centres. Therefore, it would seem unlikely that the intracranial vertebral artery would need to vasoconstrict, thus reducing its blood flow. In order to investigate the existence and location of a noradrenaline-mediated constrictor mechanism in the wall of the intracranial vertebral artery, transverse sections of ten baboon and ten monkey vessels were stained with sucrose-potassium phosphate-glyoxylic acid (counterstained with malachite-green. This method allows the visualisation of catecholaminergic nerves when the sections are exposed to ultraviolet light. In this study of primate vascular tissue, however, none of the monkey or baboon vertebral artery sections showed the presence of noradrenergic nerves in the tunica media – tunica adventitia junction or penetrating the tunica media of the arteries. These findings indicate that the intracranial vertebral artery does not have a neurogenic vasomotor function in primates.

  12. Anomalous origin of the left coronary artery from the pulmonary artery with patent ductus arteriosus: a must to recognize entity.

    Science.gov (United States)

    Awasthy, Neeraj; Marwah, Ashutosh; Sharma, Rajesh; Dalvi, Bharat

    2010-09-01

    Anomalous left coronary artery from the pulmonary trunk (ALCAPA) presents in early infancy with a clinical picture of congestive heart failure with left ventricular (LV) dysfunction and mitral insufficiency. These manifestations of myocardial ischaemia may be masked in the presence of an associated patent ductus arteriosus (PDA) or ventricular septal defect (VSD) which prevents the fall of pulmonary artery pressures and allows perfusion of the anomalous coronary artery. We present a case of a patient with large PDA-associated ALCAPA and preserved LV function. The importance of such a finding lies in the fact that VSD closure or PDA ligation in such cases would unmask the ALCAPA.

  13. Brachial artery protected by wrapped latissimus dorsi muscle flap in high voltage electrical injury

    Science.gov (United States)

    Gencel, E.; Eser, C.; Kokacya, O.; Kesiktas, E.; Yavuz, M.

    2016-01-01

    Summary High voltage electrical injury can disrupt the vascular system and lead to extremity amputations. It is important to protect main vessels from progressive burn necrosis in order to salvage a limb. The brachial artery should be totally isolated from the burned area by a muscle flap to prevent vessel disruption. In this study, we report the use of a wrap-around latissimus dorsi muscle flap to protect a skeletonized brachial artery in a high voltage electrical injury in order to salvage the upper extremity and restore function. The flap wrapped around the exposed brachial artery segment and luminal status of the artery was assessed using magnetic resonance angiography. No vascular intervention was required. The flap survived completely with good elbow function. Extremity amputation was not encountered. This method using a latissimus dorsi flap allows the surgeon to protect the main upper extremity artery and reconstruct arm defects, which contributes to restoring arm function in high voltage electrical injury. PMID:28149236

  14. A multiscale active structural model of the arterial wall accounting for smooth muscle dynamics.

    Science.gov (United States)

    Coccarelli, Alberto; Edwards, David Hughes; Aggarwal, Ankush; Nithiarasu, Perumal; Parthimos, Dimitris

    2018-02-01

    Arterial wall dynamics arise from the synergy of passive mechano-elastic properties of the vascular tissue and the active contractile behaviour of smooth muscle cells (SMCs) that form the media layer of vessels. We have developed a computational framework that incorporates both these components to account for vascular responses to mechanical and pharmacological stimuli. To validate the proposed framework and demonstrate its potential for testing hypotheses on the pathogenesis of vascular disease, we have employed a number of pharmacological probes that modulate the arterial wall contractile machinery by selectively inhibiting a range of intracellular signalling pathways. Experimental probes used on ring segments from the rabbit central ear artery are: phenylephrine, a selective α 1-adrenergic receptor agonist that induces vasoconstriction; cyclopiazonic acid (CPA), a specific inhibitor of sarcoplasmic/endoplasmic reticulum Ca 2+ -ATPase; and ryanodine, a diterpenoid that modulates Ca 2+ release from the sarcoplasmic reticulum. These interventions were able to delineate the role of membrane versus intracellular signalling, previously identified as main factors in smooth muscle contraction and the generation of vessel tone. Each SMC was modelled by a system of nonlinear differential equations that account for intracellular ionic signalling, and in particular Ca 2+ dynamics. Cytosolic Ca 2+ concentrations formed the catalytic input to a cross-bridge kinetics model. Contractile output from these cellular components forms the input to the finite-element model of the arterial rings under isometric conditions that reproduces the experimental conditions. The model does not account for the role of the endothelium, as the nitric oxide production was suppressed by the action of L-NAME, and also due to the absence of shear stress on the arterial ring, as the experimental set-up did not involve flow. Simulations generated by the integrated model closely matched experimental

  15. Automated method for relating regional pulmonary structure and function: integration of dynamic multislice CT and thin-slice high-resolution CT

    Science.gov (United States)

    Tajik, Jehangir K.; Kugelmass, Steven D.; Hoffman, Eric A.

    1993-07-01

    We have developed a method utilizing x-ray CT for relating pulmonary perfusion to global and regional anatomy, allowing for detailed study of structure to function relationships. A thick slice, high temporal resolution mode is used to follow a bolus contrast agent for blood flow evaluation and is fused with a high spatial resolution, thin slice mode to obtain structure- function detail. To aid analysis of blood flow, we have developed a software module, for our image analysis package (VIDA), to produce the combined structure-function image. Color coded images representing blood flow, mean transit time, regional tissue content, regional blood volume, regional air content, etc. are generated and imbedded in the high resolution volume image. A text file containing these values along with a voxel's 3-D coordinates is also generated. User input can be minimized to identifying the location of the pulmonary artery from which the input function to a blood flow model is derived. Any flow model utilizing one input and one output function can be easily added to a user selectable list. We present examples from our physiologic based research findings to demonstrate the strengths of combining dynamic CT and HRCT relative to other scanning modalities to uniquely characterize pulmonary normal and pathophysiology.

  16. Common carotid artery thrombosis; Clinical and radiological evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Yasuhiro; Yasuda, Takeshi; Hakusui, Shigetaka; Yanagi, Tsutomu (Nagoya Daini Red Cross Hospital (Japan)); Ito, Eiichi

    1994-02-01

    Common carotid artery thrombosis (CCAT) is not common. We studied 4 patients with CCAT to clarify the clinical and radiological features of this disorder. Case 1 had only episodes of TIA. Case 2 was diagnosed by chance as having CCAT at the time of admission due to cerebellar infarction. On the contrary, Cases 3 and 4 were admitted because of disturbance of consciousness and hemiparesis. Case 4 died soon after his stroke because of complications. We evaluated cases 1, 2 and 3 using head CT, head MRI, neck MRI, MR angiography, SPECT and cerebral angiography. Case 4, who was evaluated with head CT and cerebral angiography, was autopsied to confirm the occlusion of the common carotid artery. The clinical severity of CCAT varies from asymptomatic to severe, because each case differs in the time taken for complete occlusion of the common carotid artery; the development of collateral circulation; and hemodynamics of the brain. As for the collaterals their contribution is variable; for example, the thyrocervical and other arteries function as the bypass. We can diagnose CCAT easily and noninvasively using MR angiography and neck MRI based on disappearance of the flow void in the common carotid artery or internal carotid artery. On physical examination, it is important to detect faded pulsation of the superficial temporal artery that is ipsilateral to the occluded common carotid artery. (author).

  17. Femoral Artery Atherosclerosis Is Associated With Physical Function Across the Spectrum of the Ankle-Brachial Index: The San Diego Population Study.

    Science.gov (United States)

    Wassel, Christina L; Ellis, Alicia M; Suder, Natalie C; Barinas-Mitchell, Emma; Rifkin, Dena E; Forbang, Nketi I; Denenberg, Julie O; Marasco, Antoinette M; McQuaide, Belinda J; Jenny, Nancy S; Allison, Matthew A; Ix, Joachim H; Criqui, Michael H

    2017-07-20

    The ankle-brachial index (ABI) is inadequate to detect early-stage atherosclerotic disease, when interventions to prevent functional decline may be the most effective. We determined associations of femoral artery atherosclerosis with physical functioning, across the spectrum of the ABI, and within the normal ABI range. In 2007-2011, 1103 multiethnic men and women participated in the San Diego Population Study, and completed all components of the summary performance score. Using Doppler ultrasound, superficial and common femoral intima media thickness and plaques were ascertained. Logistic regression was used to assess associations of femoral atherosclerosis with the summary performance score and its individual components. Models were adjusted for demographics, lifestyle factors, comorbidities, lipids, and kidney function. In adjusted models, among participants with a normal-range ABI (1.00-1.30), the highest tertile of superficial intima media thickness was associated with lower odds of a perfect summary performance score of 12 (odds ratio=0.56 [0.36, 0.87], P =0.009), and lower odds of a 4-m walk score of 4 (0.34 [0.16, 0.73], P =0.006) and chair rise score of 4 (0.56 [0.34, 0.94], P =0.03). Plaque presence (0.53 [0.29, 0.99], P =0.04) and greater total plaque burden (0.61 [0.43, 0.87], P =0.006) were associated with worse 4-m walk performance in the normal-range ABI group. Higher superficial intima media thickness was associated with lower summary performance score in all individuals ( P =0.02). Findings suggest that use of femoral artery atherosclerosis measures may be effective in individuals with a normal-range ABI, especially, for example, those with diabetes mellitus or a family history of peripheral artery disease, when detection can lead to earlier intervention to prevent functional declines and improve quality of life. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  18. Three-dimensional whole-brain perfusion quantification using pseudo-continuous arterial spin labeling MRI at multiple post-labeling delays: accounting for both arterial transit time and impulse response function.

    Science.gov (United States)

    Qin, Qin; Huang, Alan J; Hua, Jun; Desmond, John E; Stevens, Robert D; van Zijl, Peter C M

    2014-02-01

    Measurement of the cerebral blood flow (CBF) with whole-brain coverage is challenging in terms of both acquisition and quantitative analysis. In order to fit arterial spin labeling-based perfusion kinetic curves, an empirical three-parameter model which characterizes the effective impulse response function (IRF) is introduced, which allows the determination of CBF, the arterial transit time (ATT) and T(1,eff). The accuracy and precision of the proposed model were compared with those of more complicated models with four or five parameters through Monte Carlo simulations. Pseudo-continuous arterial spin labeling images were acquired on a clinical 3-T scanner in 10 normal volunteers using a three-dimensional multi-shot gradient and spin echo scheme at multiple post-labeling delays to sample the kinetic curves. Voxel-wise fitting was performed using the three-parameter model and other models that contain two, four or five unknown parameters. For the two-parameter model, T(1,eff) values close to tissue and blood were assumed separately. Standard statistical analysis was conducted to compare these fitting models in various brain regions. The fitted results indicated that: (i) the estimated CBF values using the two-parameter model show appreciable dependence on the assumed T(1,eff) values; (ii) the proposed three-parameter model achieves the optimal balance between the goodness of fit and model complexity when compared among the models with explicit IRF fitting; (iii) both the two-parameter model using fixed blood T1 values for T(1,eff) and the three-parameter model provide reasonable fitting results. Using the proposed three-parameter model, the estimated CBF (46 ± 14 mL/100 g/min) and ATT (1.4 ± 0.3 s) values averaged from different brain regions are close to the literature reports; the estimated T(1,eff) values (1.9 ± 0.4 s) are higher than the tissue T1 values, possibly reflecting a contribution from the microvascular arterial blood compartment

  19. The Critical Role of Pulmonary Arterial Compliance in Pulmonary Hypertension

    Science.gov (United States)

    Prins, Kurt W.; Pritzker, Marc R.; Scandurra, John; Volmers, Karl; Weir, E. Kenneth

    2016-01-01

    The normal pulmonary circulation is a low-pressure, high-compliance system. Pulmonary arterial compliance decreases in the presence of pulmonary hypertension because of increased extracellular matrix/collagen deposition in the pulmonary arteries. Loss of pulmonary arterial compliance has been consistently shown to be a predictor of increased mortality in patients with pulmonary hypertension, even more so than pulmonary vascular resistance in some studies. Decreased pulmonary arterial compliance causes premature reflection of waves from the distal pulmonary vasculature, leading to increased pulsatile right ventricular afterload and eventually right ventricular failure. Evidence suggests that decreased pulmonary arterial compliance is a cause rather than a consequence of distal small vessel proliferative vasculopathy. Pulmonary arterial compliance decreases early in the disease process even when pulmonary artery pressure and pulmonary vascular resistance are normal, potentially enabling early diagnosis of pulmonary vascular disease, especially in high-risk populations. With the recognition of the prognostic importance of pulmonary arterial compliance, its impact on right ventricular function, and its contributory role in the development and progression of distal small-vessel proliferative vasculopathy, pulmonary arterial compliance is an attractive target for the treatment of pulmonary hypertension. PMID:26848601

  20. Invasive assessment of renal artery atherosclerotic disease and resistant hypertension before renal sympathetic denervation.

    Science.gov (United States)

    Ribichini, Flavio; Pighi, Michele; Zivelonghi, Carlo; Gambaro, Alessia; Valvo, Enrico; Lupo, Antonio; Vassanelli, Corrado

    2013-01-01

    Renal sympathetic denervation (RSD) is emerging as a new therapeutic option for patients with severe hypertension refractory to medical therapy. The presence of a renal artery stenosis may be both a cause of secondary hypertension and a contraindication to RSD if a renal artery stent is implanted; therefore, the definition of the functional importance of a renal artery stenosis in a patient with refractory hypertension is crucial. We describe the imaging and functional intravascular assessment of an angiographically severe stenosis of the renal artery in a patient with severe refractory hypertension, by means of intravascular ultrasound (IVUS), and measurement of the translesional pressure gradient with a pressure wire. Pressure wire examination excluded any severity of the stenosis, and IVUS showed the presence of a dissected plaque that resolved spontaneously after 3 months of intensive medical therapy and high-dose statin. Subsequently the patient was treated with RSD, achieving a significant effect on blood pressure control. Intravascular imaging and functional assessment of renal artery anatomy in patients with atherosclerotic disease may prove particularly suited to patients with refractory hypertension and multilevel vascular disease who are considered for endovascular therapies, either renal artery stenting or RSD.

  1. Endovascular treatment of renal artery stenoses

    International Nuclear Information System (INIS)

    Lashari, M.N.

    2015-01-01

    To evaluate the procedure success and effect on hypertension after stenting of incidentally diagnosed atherosclerotic renal artery stenoses. Study Design: An experimental study. Place and Duration of Study: A multicentric study was conducted at the Plastic Surgery and General Hospital, National Medical Center and Ziauddin University Hospital, Karachi, Pakistan from January 2009 to March 2013. Methodology: Hypertension (systolic blood pressure > 160 and diastolic > 90 mmHg with two or more than two medications) with coronary artery disease were initially evaluated for coronary angiography, Renal artery angiography was also endovascular performed and stent was deployed for atherosclerotic renal artery stenosis when found. Blood pressure readings, reduction in need of antihypertensive medication and serum creatinine levels were taken as outcome measures. Patients having renal artery stenoses secondary to connective tissue disorders and fibromuscular dysplasia were excluded. Results: There were 25 patients, 14 (56%) male and 11 (44%) female, with mean age of 49 +- 6 years. Diabetes mellitus, dyslipidemia and smoking were seen in 11 (44%), 10 (40%) and 4 (16%) patients respectively. Renal insufficiency (serum creatinine > 1.5 mg/dl) was seen in one (04%) patient. Bilateral, and isolated right and left renal artery stenoses was seen in 5 (20%), 9 (36%) and 11(44%) patients respectively. Mean percentage of renal artery stenoses was 89%, ranged from 70% to 99% while ostial lesion was found in 20 (80%) patients. A significant decrease in systolic (168.20 +- 9.987 vs. 140.60 +- 5.649 mmHg, p < 0.001) and diastolic blood pressure (88.60 +- 5.50 vs. 77.20 +- 5.017 mmHg, p < 0.001) and reduction of medication (2.72 +- 0.458 vs. 1.5 +- 0.510, p < 0.01) were noted without a change in renal function (p= 0.061) after renal artery stenting. Conclusion: Endovascular stenting of renal artery stenoses in patients with poorly controlled hypertension is a safe and effective treatment

  2. Double profunda brachii artery

    Directory of Open Access Journals (Sweden)

    Gavishiddappa A Hadimani

    2016-01-01

    Full Text Available Brachial artery (BA is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii artery 2 arises distal to the profunda brachii artery 1. Both the arteries run inferolaterally in the spiral groove along with radial nerve. Variations of profunda brachii artery are important during harvesting of the lateral arm flaps and may lead to inadvertent injury during percutaneous arterial catheterization or injection of drugs.

  3. A data input controller for an alphanumeric and function keyboard with ports to the CAMAC-dataway or the serial plasma display controller

    International Nuclear Information System (INIS)

    Zahn, J.; Komor, Z.; Geldmeyer, H.J.

    1976-01-01

    A data input controller has been developed to allow the data transfer from an alphanumeric and function keyboard to the CAMAC-dataway or via the plasma display controller SIG-8AS/S and a serial transmission line to the TTY-/V.24-port of a computer. (orig.) [de

  4. Aberrant overian artery originating from the Ilolumbar artery: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Eun; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2016-05-15

    Here, we report a case of a 30-year-old woman who presented with primary postpartum hemorrhage due to uterine atony. She received uterine artery embolization (UAE). During left internal iliac arteriography, an aberrant left ovarian artery originating from the left iliolumbar artery was visualized. The aberrant left ovarian artery was connected to the left uterine artery via prominent collateral vessels. It supplied a significant amount of blood to the fundus of the uterus. Bilateral hypertrophied uterine arteries were embolized very carefully so that the embolic material did not reflux into the aberrant left ovarian artery. After the procedure, her vaginal bleeding was successfully controlled. Accurate understanding of anatomical variations of the ovarian artery is essential to avoid failure in controlling postpartum hemorrhage with UAE.

  5. Aberrant overian artery originating from the Ilolumbar artery: A case report

    International Nuclear Information System (INIS)

    Lee, Ji Eun; Lee, Jae Myeong

    2016-01-01

    Here, we report a case of a 30-year-old woman who presented with primary postpartum hemorrhage due to uterine atony. She received uterine artery embolization (UAE). During left internal iliac arteriography, an aberrant left ovarian artery originating from the left iliolumbar artery was visualized. The aberrant left ovarian artery was connected to the left uterine artery via prominent collateral vessels. It supplied a significant amount of blood to the fundus of the uterus. Bilateral hypertrophied uterine arteries were embolized very carefully so that the embolic material did not reflux into the aberrant left ovarian artery. After the procedure, her vaginal bleeding was successfully controlled. Accurate understanding of anatomical variations of the ovarian artery is essential to avoid failure in controlling postpartum hemorrhage with UAE

  6. Oxidation modifies the structure and function of the extracellular matrix generated by human coronary artery endothelial cells.

    Science.gov (United States)

    Chuang, Christine Y; Degendorfer, Georg; Hammer, Astrid; Whitelock, John M; Malle, Ernst; Davies, Michael J

    2014-04-15

    ECM (extracellular matrix) materials, such as laminin, perlecan, type IV collagen and fibronectin, play a key role in determining the structure of the arterial wall and the properties of cells that interact with the ECM. The aim of the present study was to investigate the effect of peroxynitrous acid, an oxidant generated by activated macrophages, on the structure and function of the ECM laid down by HCAECs (human coronary artery endothelial cells) in vitro and in vivo. We show that exposure of HCAEC-derived native matrix components to peroxynitrous acid (but not decomposed oxidant) at concentrations >1 μM results in a loss of antibody recognition of perlecan, collagen IV, and cell-binding sites on laminin and fibronectin. Loss of recognition was accompanied by decreased HCAEC adhesion. Real-time PCR showed up-regulation of inflammation-associated genes, including MMP7 (matrix metalloproteinase 7) and MMP13, as well as down-regulation of the laminin α2 chain, in HCAECs cultured on peroxynitrous acid-treated matrix compared with native matrix. Immunohistochemical studies provided evidence of co-localization of laminin with 3-nitrotyrosine, a biomarker of peroxynitrous acid damage, in type II-III/IV human atherosclerotic lesions, consistent with matrix damage occurring during disease development in vivo. The results of the present study suggest a mechanism through which peroxynitrous acid modifies endothelial cell-derived native ECM proteins of the arterial basement membrane in atherosclerotic lesions. These changes to ECM and particularly perlecan and laminin may be important in inducing cellular dysfunction and contribute to atherogenesis.

  7. Early results of coronary artery bypass grafting with coronary endarterectomy for severe coronary artery disease

    Directory of Open Access Journals (Sweden)

    Toischer Karl

    2009-09-01

    Full Text Available Abstract Background Despite the existence of controversial debates on the efficiency of coronary endarterectomy (CE, it is still used as an adjunct to coronary artery bypass grafting (CABG. This is particularly true in patients with endstage coronary artery disease. Given the improvements in cardiac surgery and postoperative care, as well as the rising number of elderly patient with numerous co-morbidities, re-evaluating the pros and cons of this technique is needed. Methods Patient demographic information, operative details and outcome data of 104 patients with diffuse calcified coronary artery disease were retrospectively analyzed with respect to functional capacity (NYHA, angina pectoris (CCS and mortality. Actuarial survival was reported using a Kaplan-Meyer analysis. Results Between August 2001 and March 2005, 104 patients underwent coronary artery bypass grafting (CABG with adjunctive coronary endarterectomy (CE in the Department of Thoracic-, Cardiac- and Vascular Surgery, University of Goettingen. Four patients were lost during follow-up. Data were gained from 88 male and 12 female patients; mean age was 65.5 ± 9 years. A total of 396 vessels were bypassed (4 ± 0.9 vessels per patient. In 98% left internal thoracic artery (LITA was used as arterial bypass graft and a total of 114 vessels were endarterectomized. CE was performed on right coronary artery (RCA (n = 55, on left anterior descending artery (LAD (n = 52 and circumflex artery (RCX (n = 7. Ninety-five patients suffered from 3-vessel-disease, 3 from 2-vessel- and 2 from 1-vessel-disease. Closed technique was used in 18%, open technique in 79% and in 3% a combination of both. The most frequent endarterectomized localization was right coronary artery (RCA = 55%. Despite the severity of endstage atherosclerosis, hospital mortality was only 5% (n = 5. During follow-up (24.5 ± 13.4 months, which is 96% complete (4 patients were lost caused by unknown address 8 patients died (cardiac

  8. A Novel Interpretation for Arterial Pulse Pressure Amplification in Health and Disease

    Directory of Open Access Journals (Sweden)

    Manuel R. Alfonso

    2018-01-01

    Full Text Available Arterial pressure waves have been described in one dimension using several approaches, such as lumped (Windkessel or distributed (using Navier-Stokes equations models. An alternative approach consists of modeling blood pressure waves using a Korteweg-de Vries (KdV equation and representing pressure waves as combinations of solitons. This model captures many key features of wave propagation in the systemic network and, in particular, pulse pressure amplification (PPA, which is a mechanical biomarker of cardiovascular risk. The main objective of this work is to compare the propagation dynamics described by a KdV equation in a human-like arterial tree using acquired pressure waves. Furthermore, we analyzed the ability of our model to reproduce induced elastic changes in PPA due to different pathological conditions. To this end, numerical simulations were performed using acquired central pressure signals from different subject groups (young, adults, and hypertensive as input and then comparing the output of the model with measured radial artery pressure waveforms. Pathological conditions were modeled as changes in arterial elasticity (E. Numerical results showed that the model was able to propagate acquired pressure waveforms and to reproduce PPA variations as a consequence of elastic changes. Calculated elasticity for each group was in accordance with the existing literature.

  9. PERMODELAN INDEKS HARGA KONSUMEN INDONESIA DENGAN MENGGUNAKAN MODEL INTERVENSI MULTI INPUT

    KAUST Repository

    Novianti, Putri Wikie; Suhartono, Suhartono

    2017-01-01

    -searches that have been done are only contain of an intervention with single input, ei-ther step or pulse function. Multi input intervention was used in Indonesia CPI case because there are some events which are expected effecting CPI. Based on the result, those

  10. Differential expression of pancreatitis-associated protein and thrombospondins in arterial versus venous tissues.

    Science.gov (United States)

    Szasz, Theodora; Eddy, Susan; Paulauskis, Joseph; Burnett, Robert; Ellekilde, Merete; Iovanna, Juan L; Watts, Stephanie W

    2009-01-01

    Arteries and veins modulate cardiovascular homeostasis and contribute to hypertension pathogenesis. Functional differences between arteries and veins are based upon differences in gene expression. To better characterize these expression patterns, and to identify candidate genes that could be manipulated selectively in the venous system, we performed whole genome expression profiling of arteries and veins. We used the CodeLink platform and the major artery (thoracic aorta) and vein (caudal vena cava) of the rat. The most prominent difference was pancreatitis-associated protein (PAP1), expressed 64-fold higher in vena cava versus aorta. Expression of mRNA for thrombospondins (TSP-1, TSP-4) was greater than 5-fold higher in veins versus arteries. Higher mRNA expression of TSP-1, TSP-2, TSP-4 and PAP1 in vena cava versus aorta was confirmed by PCR. Immunohistochemical analysis of tissue sections qualitatively confirmed a higher expression of these proteins in vena cava versus aorta. This is the first gene array study of adult rat arterial and venous tissues, and also the first study to report differences in inflammatory genes between arteries and veins. Data from these studies may provide novel insights into the genetic basis for functional differences between arteries and veins in health and disease. Copyright 2009 S. Karger AG, Basel.

  11. Differential expression of pancreatitis associated protein and thrombospondins in arterial vs venous tissues

    Science.gov (United States)

    Szasz, Theodora; Eddy, Susan; Paulauskis, Joseph; Burnett, Robert; Ellekilde, Merete; Iovanna, Juan L.; Watts, Stephanie W.

    2015-01-01

    BACKGROUND/AIMS Arteries and veins modulate cardiovascular homeostasis and contribute to hypertension pathogenesis. Functional differences between arteries and veins are based upon differences in gene expression. To better characterize these expression patterns, and to identify candidate genes that could be manipulated selectively in the venous system, we performed whole genome expression profiling of arteries and veins. METHODS We used the CodeLink platform and the major artery (thoracic aorta) and vein (caudal vena cava) of the rat. RESULTS The most prominent difference was pancreatitis associated protein (PAP1), expressed 64-fold higher in vena cava vs aorta. Expression of mRNA for thrombospondins (TSP-1, TSP-4) was greater than 5-fold higher in veins vs arteries. Higher mRNA expression of thrombospondins (TSP-1, 2, 4) and PAP1 in vena cava vs aorta was confirmed by PCR. Immunohistochemical analysis of tissue sections qualitatively confirmed a higher expression of these proteins in vena cava vs aorta. CONCLUSION This is the first gene array study of adult rat arterial and venous tissues, and also the first study to report differences in inflammatory genes between arteries and veins. Data from these studies may provide novel insights into the genetic basis for functional differences between arteries and veins in health and disease. PMID:19571575

  12. 3',4'-Dihydroxyflavonol reduces superoxide and improves nitric oxide function in diabetic rat mesenteric arteries.

    Directory of Open Access Journals (Sweden)

    Chen-Huei Leo

    Full Text Available 3',4'-Dihydroxyflavonol (DiOHF is an effective antioxidant that acutely preserves nitric oxide (NO activity in the presence of elevated reactive oxygen species (ROS. We hypothesized that DiOHF treatment (7 days, 1 mg/kg per day s.c. would improve relaxation in mesenteric arteries from diabetic rats where endothelial dysfunction is associated with elevated oxidant stress.In mesenteric arteries from diabetic rats there was an increase in ROS, measured by L-012 and 2',7'-dichlorodihydrofluorescein diacetate fluorescence. NADPH oxidase-derived superoxide levels, assayed by lucigenin chemiluminescence, were also significantly increased in diabetic mesenteric arteries (diabetes, 4892±946 counts/mg versus normal 2486±344 counts/mg, n = 7-10, p<0.01 associated with an increase in Nox2 expression but DiOHF (2094±300 counts/mg, n = 10, p<0.001 reversed that effect. Acetylcholine (ACh-induced relaxation of mesenteric arteries was assessed using wire myography (pEC(50 = 7.94±0.13 n = 12. Diabetes significantly reduced the sensitivity to ACh and treatment with DiOHF prevented endothelial dysfunction (pEC(50, diabetic 6.86±0.12 versus diabetic+DiOHF, 7.49±0.13, n = 11, p<0.01. The contribution of NO versus endothelium-derived hyperpolarizing factor (EDHF to ACh-induced relaxation was assessed by evaluating responses in the presence of TRAM-34+apamin+iberiotoxin or N-nitro-L-arginine+ODQ respectively. Diabetes impaired the contribution of both NO (maximum relaxation, R(max diabetic 24±7 versus normal, 68±10, n = 9-10, p<0.01 and EDHF (pEC(50, diabetic 6.63±0.15 versus normal, 7.14±0.12, n = 10-11, p<0.01 to endothelium-dependent relaxation. DiOHF treatment did not significantly affect the EDHF contribution but enhanced NO-mediated relaxation (R(max 69±6, n = 11, p<0.01. Western blotting demonstrated that diabetes also decreased expression and increased uncoupling of endothelial NO synthase (eNOS. Treatment of the

  13. Cerebellar arteries originating from the internal carotid artery: angiographic evaluation and embryologic explanations

    International Nuclear Information System (INIS)

    Lee, Jae Young; Han, Moon Hee; Yu, In Gyu; Chang, Ki Hyun; Kim, Eui Jong; Kim, Dae Ho

    1997-01-01

    To find and describe the cerebellar arteries arising from the internal carotid artery, explain them embryologically, and evaluate their clinical implication. To determine the point in the internal carotid artery from which the cereballar artery arose anomalously, consecutive angiographic studies performed in the last three years were reviewed. The distribution of such anomalous cerebellar arteries, the point in the internal carotid artery from which the anomalous vessels originated, and associated findings were analyzed. Five anomalous origins of cerebellar arteries arising arising directly from the internal carotid artery were found in five patients. Three anterior inferior cerebellar arteries (AICA) and one common trunk of an AICA and a posterior inferior cerebellar artery (PICA) were found to originate from the internal carotid artery at a point close to the origin of the primitive trigeminal artery. A PICA arose from an artery presenting a course similar to the proatlantal intersegmental artery. Intracranial aneurysms in two patients, Moyamoya disease in one, and facial arteriovenous malformation in one. In our series, AICAs supplied from the arteries considered to be persistent trigeminal artery variants were the most common type. A correlation between type of anomalous cerebellar artery and type of carotid-vertebrobasilar anastomosis may exist. Cerebellar arteries originating anomalously from the internal carotid artery seem to occur as a result of the persistence of carotid-vertebrobasilar anastomoses associated with incomplete fusion of the longitudinal neural arteries. An understanding of these anomalous cerebellar arteries may help prevent accidents during therapeutic embolization and surgical treatment, as well as misinterpretation

  14. A Case of Pulmonary Hypertension Due to Fistulas Between Multiple Systemic Arteries and the Right Pulmonary Artery in an Adult Discovered for Occulted Dyspnoea.

    Science.gov (United States)

    Li, Ji-Feng; Zhai, Zhen-Guo; Kuang, Tu-Guang; Liu, Min; Ma, Zhan-Hong; Li, Yi-Dan; Yang, Yuan-Hua

    2017-08-01

    Pulmonary hypertension (PH) can be caused by a fistula between the systemic and pulmonary arteries. Here, we report a case of PH due to multiple fistulas between systemic arteries and the right pulmonary artery where the ventilation/perfusion scan showed no perfusion in the right lung. A 32-year-old male patient was hospitalised for community-acquired pneumonia. After treatment with antibiotics, the pneumonia was alleviated but dyspnoea persisted. Pulmonary hypertension was diagnosed using right heart catheterisation, which detected the mean pulmonary artery pressure as 37mmHg. The anomalies were confirmed by contrast-enhanced CT scan (CT pulmonary angiography), systemic arterial angiography and pulmonary angiography. Following embolisation of the largest fistula, the haemodynamics and oxygen dynamics did not improve, and even worsened to some extent. After supportive therapy including diuretics and oxygen, the patient's dyspnoea, WHO function class and right heart function by transthoracic echocardiography all improved during follow-up. Pulmonary hypertension can be present even when the right lung perfusion is lost. Closure of fistulas by embolisation, when those fistulas act as the proliferating vessels, may be harmful. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  15. Monte Carlo simulations used to calculate the energy deposited in the coronary artery lumen as a function of iodine concentration and photon energy.

    Science.gov (United States)

    Hocine, Nora; Meignan, Michel; Masset, Hélène

    2018-04-01

    To better understand the risks of cumulative medical X-ray investigations and the possible causal role of contrast agent on the coronary artery wall, the correlation between iodinated contrast media and the increase of energy deposited in the coronary artery lumen as a function of iodine concentration and photon energy is investigated. The calculations of energy deposition have been performed using Monte Carlo (MC) simulation codes, namely PENetration and Energy LOss of Positrons and Electrons (PENELOPE) and Monte Carlo N-Particle eXtended (MCNPX). Exposure of a cylinder phantom, artery and a metal stent (AISI 316L) to several X-ray photon beams were simulated. For the energies used in cardiac imaging the energy deposited in the coronary artery lumen increases with the quantity of iodine. Monte Carlo calculations indicate a strong dependence of the energy enhancement factor (EEF) on photon energy and iodine concentration. The maximum value of EEF is equal to 25; this factor is showed for 83 keV and for 400 mg Iodine/mL. No significant impact of the stent is observed on the absorbed dose in the artery for incident X-ray beams with mean energies of 44, 48, 52 and 55 keV. A strong correlation was shown between the increase in the concentration of iodine and the energy deposited in the coronary artery lumen for the energies used in cardiac imaging and over the energy range between 44 and 55 keV. The data provided by this study could be useful for creating new medical imaging protocols to obtain better diagnostic information with a lower level of radiation exposure.

  16. Application and influence of preoperative intervention intra-arterial chemotherapy (NAC) of uterine artery for endometrial carcinoma

    International Nuclear Information System (INIS)

    Zhu Xueqiong; Yue Tianfu; Wang Dehua

    2001-01-01

    Objective: To analyse the effect of preoperative persistent infusion chemotherapy via uterine artery on endometrial carcinoma and followed by hysterectomy. Methods: According to the Seldinger's technique, polyethylene catheter was super selected into the uterine artery. The drugs were infused with cisplatin 100 mg and doxorubicin 50 mg in a consecutive low-dose method for five days. Radical surgery was performed about three or four weeks after NAC. The NAC group (n = 20) underwent surgery following intra-arterial chemotherapy, while the control group (n = 40) was randomly selected among the patients of endometrial carcinoma performed operations in the hospital. Results: One (5.0%) patient showed complete response in NAC group, the rates of complete response plus partial response were 60.0%. There were no significant differences in bleeding amounts, the operation time, the function recovery of bladder and bowel, the healing time of the incision between the two groups. Compared with the control group, infiltration larger than half of myometrium and lymph nodes involvement were statistically significant lower in NAC group (P < 0.05). Conclusions: Preparing intra-arterial chemotherapy may reduce tumor volume and possibly eradicate subclinical metastases without increasing the incidence of operative complications

  17. Expression of melatonin receptors in arteries involved in thermoregulation

    International Nuclear Information System (INIS)

    Viswanathan, M.; Laitinen, J.T.; Saavedra, J.M.

    1990-01-01

    Melatonin binding sites were localized and characterized in the vasculature of the rat by using the melatonin analogue 2-[125I]iodomelatonin (125I-melatonin) and quantitative in vitro autoradiography. The expression of these sites was restricted to the caudal artery and to the arteries that form the circle of Willis at the base of the brain. The arterial 125I-melatonin binding was stable, saturable, and reversible. Saturation studies revealed that the binding represented a single class of high-affinity binding sites with a dissociation constant (Kd) of 3.4 x 10(-11) M in the anterior cerebral artery and 1.05 x 10(-10) M in the caudal artery. The binding capacities (Bmax) in these arteries were 19 and 15 fmol/mg of protein, respectively. The relative order of potency of indoles for inhibition of 125I-melatonin binding at these sites was typical of a melatonin receptor: 2-iodomelatonin greater than melatonin greater than N-acetylserotonin much much greater than 5-hydroxytryptamine. Norepinephrine-induced contraction of the caudal artery in vitro was significantly prolonged and potentiated by melatonin in a concentration-dependent manner, suggesting that these arterial binding sites are functional melatonin receptors. Neither primary steps in smooth muscle contraction (inositol phospholipid hydrolysis) nor relaxation (adenylate cyclase activation) were affected by melatonin. Melatonin, through its action on the tone of these arteries, may cause circulatory adjustments in these arteries, which are believed to be involved in thermoregulation

  18. Aberrant ovarian artery arising from the common Iliac artery: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won Kyung [Dept. of Radiology, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Yang, Seung Boo; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University Gumi Hospital, Soonchunhyang University College of Medicine, Gumi (Korea, Republic of); Goo, Dong Erk; Kim, Yong Jae; Chang, Yun Woo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    2013-01-15

    A 46-year-old Vietnamese woman received embolization therapy in order to control postpartum hemorrhage. Angiography revealed an aberrant ovarian artery arising from the right common iliac artery. Superselective catheterization and subsequent embolization of the aberrant ovarian artery and bilateral uterine arteries were performed. Precise knowledge of the anatomic variations of the ovarian artery is important for successful embolization.

  19. Aberrant ovarian artery arising from the common Iliac artery: Case report

    International Nuclear Information System (INIS)

    Kim, Won Kyung; Yang, Seung Boo; Lee, Jae Myeong; Goo, Dong Erk; Kim, Yong Jae; Chang, Yun Woo

    2013-01-01

    A 46-year-old Vietnamese woman received embolization therapy in order to control postpartum hemorrhage. Angiography revealed an aberrant ovarian artery arising from the right common iliac artery. Superselective catheterization and subsequent embolization of the aberrant ovarian artery and bilateral uterine arteries were performed. Precise knowledge of the anatomic variations of the ovarian artery is important for successful embolization.

  20. Techniques for Non-Invasive Monitoring of Arterial Blood Pressure

    Directory of Open Access Journals (Sweden)

    Agnes S. Meidert

    2018-01-01

    Full Text Available Since both, hypotension and hypertension, can potentially impair the function of vital organs such as heart, brain, or kidneys, monitoring of arterial blood pressure (BP is a mainstay of hemodynamic monitoring in acutely or critically ill patients. Arterial BP can either be obtained invasively via an arterial catheter or non-invasively. Non-invasive BP measurement provides either intermittent or continuous readings. Most commonly, an occluding upper arm cuff is used for intermittent non-invasive monitoring. BP values are then obtained either manually (by auscultation of Korotkoff sounds or palpation or automatically (e.g., by oscillometry. For continuous non-invasive BP monitoring, the volume clamp method or arterial applanation tonometry can be used. Both techniques enable the arterial waveform and BP values to be obtained continuously. This article describes the different techniques for non-invasive BP measurement, their advantages and limitations, and their clinical applicability.

  1. Evaluation of changes in left ventricular structure and function in hypertensive patients with coronary artery disease after PCI using real-time three-dimensional echocardiography.

    Science.gov (United States)

    Meng, Yanhong; Zong, Ling; Zhang, Ziteng; Han, Youdong; Wang, Yanhui

    2018-02-01

    We aimed to evaluate the changes in left ventricular structure and function in hypertensive patients with coronary artery disease before and after percutaneous coronary intervention (PCI) using real-time three-dimensional echocardiography. Two hundred and eighty hypertensive patients with coronary artery disease undergoing PCI and 120 cases who did not receive PCI in our hospital were selected as the subjects of our study. All patients were administered with routine antiplatelet, anticoagulant, lipid-lowering, antihypertensive, dilating coronary artery and other medications. The left ventricular systolic function and systolic synchrony index changes before and after subjects were treated by PCI were analyzed using three-dimensional echocardiography. At 2 days before surgery, there were no significant differences in the left ventricular end-diastolic volume, left ventricular end-systolic volume (LVESV) and ejection fraction (EF) between the two patient groups (P>0.05). At 3 months and 9 months, the two key time points after PCI, the LVESV level in the PCI group was distinctly decreased, while EF was significantly increased (P0.05); however, the parameters of time from the corresponding segment of the myocardium to the minimal systolic volume in patients in the PCI group were significantly reduced at 3 and 9 months after surgery (PPCI accurately and in real-time, which may play a significant role.

  2. Differential impact of diabetes mellitus type II and arterial hypertension on collateral artery growth and concomitant macrophage accumulation.

    Science.gov (United States)

    Ito, Wulf D; Lund, Natalie; Sager, Hendrik; Becker, Wiebke; Wenzel, Ulrich

    2015-01-01

    Diabetes mellitus type II and arterial hypertension are major risk factors for peripheral arterial disease and have been considered to reduce collateral growth (arteriogenesis). Collateral growth proceeds through different stages. Vascular proliferation and macrophage accumulation are hallmarks of early collateral growth. We here compare the impact of arterial hypertension and diabetes mellitus type II on collateral proliferation (Brdu incorporation) and macrophage accumulation (ED 2 staining) as well as collateral vessel function (collateral conductance) in a rat model of peripheral vascular disease (femoral artery occlusion), diabetes mellitus type II (Zucker fatty diabetic rats and Zucker lean rat controls) and arterial hypertension (induced via clip placement around the right renal arteriy). We furthermore tested the impact of monocyte chemoattractant protein-1 (MCP‑1) on collateral proliferation and macrophage accumulation in these models Diabetic animals showed reduced vascular proliferation and macrophage accumulation, which however did not translate into a change of collateral conductance. Hypertensive animals on the contrary had reduced collateral conductances without altered macrophage accumulation and only a marginal reduction in collateral proliferation. Infusion of MCP‑1 only enhanced vascular proliferation in diabetic animals. These findings illustrate that impaired monocyte/macrophage recruitment is responsible for reduced collateral growth under diabetic conditions but not in arterial hypertension suggesting that diabetes mellitus in particular affects early stages of collateral growth whereas hypertension has its impact on later remodeling stages. Successful pro-arteriogenic treatment strategies in a patient population that presents with diabetes mellitus and arterial hypertension need to address different stages of collateral growth and thus different molecular and cellular targets simultaneously.

  3. Patent ductus arteriosus associated with congenital anomaly of coronary artery.

    Science.gov (United States)

    Maleki, Majid; Azizian, Nassrin; Esmaeilzadeh, Maryam; Moradi, Bahieh

    2013-11-01

    We reported a case of patent ductus arteriosus (PDA) with congenital anomaly of coronary arteries as abnormal origin of right coronary artery (RCA) and left coronary artery (LCA) from a single ostium of the right coronary sinus. A 21-year-old man referred to our institution for evaluation of cardiac murmur. He has suffered from palpitation and atypical chest pain for three months. On physical examination, a continuous murmur was heard in the second left parasternal space. Transthoracic echocardiography showed normal left and right ventricular size and systolic function (LVEF = 55%). Main pulmonary artery (PA) and left pulmonary artery (LPA) branch were considerably dilated. Considering normal coronary flow, lack of clinical evidence of myocardial ischemia and echocardiography findings, patient underwent surgical closure of PDA via left thoracotomy and after five days discharged uneventfully.

  4. [Surgical angioplasty of the left main coronary artery].

    Science.gov (United States)

    Vranes, Mile; Velinović, Milos; Kocica, Mladen; Mikić, Aleksandar; Velimirović, Dusan; Djukić, Petar

    2010-01-01

    The conventional treatment for isolated stenosis of the left main coronary artery is bypass surgery (myocardial revascularization). However, the process of atherosclerosis is not arrested by myocardial revascularization and it will lead to the occlusion of the left main coronary artery. Revascularization will establish retrograde perfusion for 50-70% of the myocardium of the left ventricle. Direct surgical angioplasty of the left main coronary artery enables normal physiological perfusion of the whole myocardium and better myocardial function. The aim of our study is to point out a new surgical approach of treating left main coronary artery stenosis. Between October 2002 and October 2003, direct surgical angioplasty of the main left coronary artery was performed on three patients with isolated stenosis of the left main coronary artery using the anterior approach and the pericardium as a patch. The procedure was performed under total endotracheal anaesthesia and standard cardiopulmonary circulation, moderate hypothermia, anterograde St. Tomas cardioplegia and local cooling. Patients were followed clinically, echocardiographically and by load-tests. All three patients were without complications. In postoperative follow-up (54-68 months) neither angina pectoris nor electrocardiographically registered ischaemic changes were found. Load-tests performed every six months on all three patients were negative. Surgical angioplasty of isolated stenosis of the left main coronary artery is a preferred method for treating this type of coronary disease. Contraindications for this type of treatment are stenosis of the left main coronary artery with bifurcation and advanced calcification of the left main coronary artery.

  5. Measurement of canine pancreatic perfusion using dynamic computed tomography: Influence of input-output vessels on deconvolution and maximum slope methods

    Energy Technology Data Exchange (ETDEWEB)

    Kishimoto, Miori, E-mail: miori@mx6.et.tiki.ne.jp [Department of Clinical Veterinary Science, Obihiro University of Agriculture and Veterinary Medicine, Nishi 2-11 Inada-cho, Obihiro 080-8555 (Japan); Tsuji, Yoshihisa, E-mail: y.tsuji@extra.ocn.ne.jp [Department of Gastroenterology and Hepatology, Kyoto University Graduate School of Medicine, Shogoinkawara-cho 54, Sakyo-ku 606-8507 (Japan); Katabami, Nana; Shimizu, Junichiro; Lee, Ki-Ja [Department of Clinical Veterinary Science, Obihiro University of Agriculture and Veterinary Medicine, Nishi 2-11 Inada-cho, Obihiro 080-8555 (Japan); Iwasaki, Toshiroh [Department of Veterinary Internal Medicine, Tokyo University of Agriculture and Technology, Saiwai-cho, 3-5-8, Fuchu 183-8509 (Japan); Miyake, Yoh-Ichi [Department of Clinical Veterinary Science, Obihiro University of Agriculture and Veterinary Medicine, Nishi 2-11 Inada-cho, Obihiro 080-8555 (Japan); Yazumi, Shujiro [Digestive Disease Center, Kitano Hospital, 2-4-20 Ougi-machi, Kita-ku, Osaka 530-8480 (Japan); Chiba, Tsutomu [Department of Gastroenterology and Hepatology, Kyoto University Graduate School of Medicine, Shogoinkawara-cho 54, Sakyo-ku 606-8507 (Japan); Yamada, Kazutaka, E-mail: kyamada@obihiro.ac.jp [Department of Clinical Veterinary Science, Obihiro University of Agriculture and Veterinary Medicine, Nishi 2-11 Inada-cho, Obihiro 080-8555 (Japan)

    2011-01-15

    Objective: We investigated whether the prerequisite of the maximum slope and deconvolution methods are satisfied in pancreatic perfusion CT and whether the measured parameters between these algorithms are correlated. Methods: We examined nine beagles injected with iohexol (200 mgI kg{sup -1}) at 5.0 ml s{sup -1}. The abdominal aorta and splenic and celiac arteries were selected as the input arteries and the splenic vein, the output veins. For the maximum slope method, we determined the arterial contrast volume of each artery by measuring the area under the curve (AUC) and compared the peak enhancement time in the pancreas with the contrast appearance time in the splenic vein. For the deconvolution method, the artery-to-vein collection rate of contrast medium was calculated. We calculated the pancreatic tissue blood flow (TBF), tissue blood volume (TBV), and mean transit time (MTT) using both algorithms and investigated their correlation based on vessel selection. Results: The artery AUC significantly decreased as it neared the pancreas (P < 0.01). In all cases, the peak time of the pancreas (11.5 {+-} 1.6) was shorter than the appearance time (14.1 {+-} 1.6) in the splenic vein. The splenic artery-vein combination exhibited the highest collection rate (91.1%) and was the only combination that was significantly correlated between TBF, TBV, and MTT in both algorithms. Conclusion: Selection of a vessel nearest to the pancreas is considered as a more appropriate prerequisite. Therefore, vessel selection is important in comparison of the semi-quantitative parameters obtained by different algorithms.

  6. Measurement of canine pancreatic perfusion using dynamic computed tomography: Influence of input-output vessels on deconvolution and maximum slope methods

    International Nuclear Information System (INIS)

    Kishimoto, Miori; Tsuji, Yoshihisa; Katabami, Nana; Shimizu, Junichiro; Lee, Ki-Ja; Iwasaki, Toshiroh; Miyake, Yoh-Ichi; Yazumi, Shujiro; Chiba, Tsutomu; Yamada, Kazutaka

    2011-01-01

    Objective: We investigated whether the prerequisite of the maximum slope and deconvolution methods are satisfied in pancreatic perfusion CT and whether the measured parameters between these algorithms are correlated. Methods: We examined nine beagles injected with iohexol (200 mgI kg -1 ) at 5.0 ml s -1 . The abdominal aorta and splenic and celiac arteries were selected as the input arteries and the splenic vein, the output veins. For the maximum slope method, we determined the arterial contrast volume of each artery by measuring the area under the curve (AUC) and compared the peak enhancement time in the pancreas with the contrast appearance time in the splenic vein. For the deconvolution method, the artery-to-vein collection rate of contrast medium was calculated. We calculated the pancreatic tissue blood flow (TBF), tissue blood volume (TBV), and mean transit time (MTT) using both algorithms and investigated their correlation based on vessel selection. Results: The artery AUC significantly decreased as it neared the pancreas (P < 0.01). In all cases, the peak time of the pancreas (11.5 ± 1.6) was shorter than the appearance time (14.1 ± 1.6) in the splenic vein. The splenic artery-vein combination exhibited the highest collection rate (91.1%) and was the only combination that was significantly correlated between TBF, TBV, and MTT in both algorithms. Conclusion: Selection of a vessel nearest to the pancreas is considered as a more appropriate prerequisite. Therefore, vessel selection is important in comparison of the semi-quantitative parameters obtained by different algorithms.

  7. [11C]Harmine Binding to Brain Monoamine Oxidase A: Test-Retest Properties and Noninvasive Quantification.

    Science.gov (United States)

    Zanderigo, Francesca; D'Agostino, Alexandra E; Joshi, Nandita; Schain, Martin; Kumar, Dileep; Parsey, Ramin V; DeLorenzo, Christine; Mann, J John

    2018-02-08

    Inhibition of the isoform A of monoamine oxidase (MAO-A), a mitochondrial enzyme catalyzing deamination of monoamine neurotransmitters, is useful in treatment of depression and anxiety disorders. [ 11 C]harmine, a MAO-A PET radioligand, has been used to study mood disorders and antidepressant treatment. However, [ 11 C]harmine binding test-retest characteristics have to date only been partially investigated. Furthermore, since MAO-A is ubiquitously expressed, no reference region is available, thus requiring arterial blood sampling during PET scanning. Here, we investigate [ 11 C]harmine binding measurements test-retest properties; assess effects of using a minimally invasive input function estimation on binding quantification and repeatability; and explore binding potentials estimation using a reference region-free approach. Quantification of [ 11 C]harmine distribution volume (V T ) via kinetic models and graphical analyses was compared based on absolute test-retest percent difference (TRPD), intraclass correlation coefficient (ICC), and identifiability. The optimal procedure was also used with a simultaneously estimated input function in place of the measured curve. Lastly, an approach for binding potentials quantification in absence of a reference region was evaluated. [ 11 C]harmine V T estimates quantified using arterial blood and kinetic modeling showed average absolute TRPD values of 7.7 to 15.6 %, and ICC values between 0.56 and 0.86, across brain regions. Using simultaneous estimation (SIME) of input function resulted in V T estimates close to those obtained using arterial input function (r = 0.951, slope = 1.073, intercept = - 1.037), with numerically but not statistically higher test-retest difference (range 16.6 to 22.0 %), but with overall poor ICC values, between 0.30 and 0.57. Prospective studies using [ 11 C]harmine are possible given its test-retest repeatability when binding is quantified using arterial blood. Results with SIME of

  8. Left Ventricular Function in Patients with Pulmonary Arterial Hypertension: The Role of Two-Dimensional Speckle Tracking Strain.

    Science.gov (United States)

    de Amorim Corrêa, Ricardo; de Oliveira, Fernanda Brito; Barbosa, Marcia M; Barbosa, Jose Augusto A; Carvalho, Taís Soares; Barreto, Michele Campos; Campos, Frederico Thadeu A F; Nunes, Maria Carmo Pereira

    2016-09-01

    Pulmonary arterial hypertension (PAH) is characterized by elevated mean pulmonary arterial pressure with abnormal right ventricular (RV) pressure overload that may alter left ventricular (LV) function. The aim of this study was to assess the impact of RV pressure overload on LV function in PAH patients using two-dimensional (2D) speckle tracking strain. The study enrolled 37 group 1 PAH patients and 38 age- and gender-matched healthy controls. LV longitudinal and radial 2D strains were measured with and without including the ventricular septum. Six-minute walk test (6MWT) and brain natriuretic peptide (BNP) levels were also obtained in patients with PAH. The mean age of patients was 46.4 ± 14.8 years, 76% women, and 16 patients (43%) had schistosomiasis. Sixteen patients (43%) were in WHO class III or IV under specific treatment for PAH. The overall 6MWT distance was 441 meters, and the BNP levels were 80 pg/mL. Patients with PAH more commonly presented with LV diastolic dysfunction and impairment of RV function when compared to controls. LV global longitudinal and radial strains were lower in patients than in controls (-17.9 ± 2.8 vs. -20.5 ± 1.9; P < 0.001 and 30.8 ± 10.5 vs. 49.8 ± 15.4; P < 0.001, respectively). After excluding septal values, LV longitudinal and radial strains remained lower in patients than in controls. The independent factors associated with global LV longitudinal strain were LV ejection fraction, RV fractional area change, and tricuspid annular systolic motion. This study showed impaired LV contractility in patients with PAH assessed by speckle tracking strain, irrespective of ventricular septal involvement. Global LV longitudinal strain was associated independently with RV fractional area change and tricuspid annular systolic motion, after adjustment for LV ejection fraction. © 2016, Wiley Periodicals, Inc.

  9. Access to the ophthalmic artery by retrograde approach through the posterior communicating artery for intra-arterial chemotherapy of retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Chi-Tuan; Blanc, Raphael; Pistocchi, Silvia; Bartolini, Bruno; Piotin, Michel [Fondation Rothschild Hospital, Department of Interventional Neuroradiology, Paris (France); Lumbroso-Le Rouic, Livia [Institut Curie, Department of Ocular Oncology, Paris (France)

    2012-08-15

    Intra-arterial infusion of chemotherapy into the ophthalmic artery for treatment of retinoblastoma has been realized after catheterization of the internal carotid and temporary balloon occlusion beyond the orifice of the ophthalmic artery, or more recently after superselective canulation of the ophthalmic artery by a microcatheter. The superselective catheterization of the ophthalmic artery could be cumbersome because of the implantation of the ostium on the carotid siphon or because of the tortuosity of the carotid siphon. We report our experience of using a retrograde approach through the posterior communicating artery that allows a more direct angle of access to the origin of the ophthalmic artery. (orig.)

  10. Canonical multi-valued input Reed-Muller trees and forms

    Science.gov (United States)

    Perkowski, M. A.; Johnson, P. D.

    1991-01-01

    There is recently an increased interest in logic synthesis using EXOR gates. The paper introduces the fundamental concept of Orthogonal Expansion, which generalizes the ring form of the Shannon expansion to the logic with multiple-valued (mv) inputs. Based on this concept we are able to define a family of canonical tree circuits. Such circuits can be considered for binary and multiple-valued input cases. They can be multi-level (trees and DAG's) or flattened to two-level AND-EXOR circuits. Input decoders similar to those used in Sum of Products (SOP) PLA's are used in realizations of multiple-valued input functions. In the case of the binary logic the family of flattened AND-EXOR circuits includes several forms discussed by Davio and Green. For the case of the logic with multiple-valued inputs, the family of the flattened mv AND-EXOR circuits includes three expansions known from literature and two new expansions.

  11. The Input-Output Relationship of the Cholinergic Basal Forebrain

    Directory of Open Access Journals (Sweden)

    Matthew R. Gielow

    2017-02-01

    Full Text Available Basal forebrain cholinergic neurons influence cortical state, plasticity, learning, and attention. They collectively innervate the entire cerebral cortex, differentially controlling acetylcholine efflux across different cortical areas and timescales. Such control might be achieved by differential inputs driving separable cholinergic outputs, although no input-output relationship on a brain-wide level has ever been demonstrated. Here, we identify input neurons to cholinergic cells projecting to specific cortical regions by infecting cholinergic axon terminals with a monosynaptically restricted viral tracer. This approach revealed several circuit motifs, such as central amygdala neurons synapsing onto basolateral amygdala-projecting cholinergic neurons or strong somatosensory cortical input to motor cortex-projecting cholinergic neurons. The presence of input cells in the parasympathetic midbrain nuclei contacting frontally projecting cholinergic neurons suggest that the network regulating the inner eye muscles are additionally regulating cortical state via acetylcholine efflux. This dataset enables future circuit-level experiments to identify drivers of known cortical cholinergic functions.

  12. S1P1 receptor modulation preserves vascular function in mesenteric and coronary arteries after CPB in the rat independent of depletion of lymphocytes.

    Directory of Open Access Journals (Sweden)

    Iryna V Samarska

    Full Text Available BACKGROUND: Cardiopulmonary bypass (CPB may induce systemic inflammation and vascular dysfunction. Sphingosine 1-phosphate (S1P modulates various vascular and immune responses. Here we explored whether agonists of the S1P receptors, FTY720 and SEW2871 improve vascular reactivity after CPB in the rat. METHODS: Experiments were done in male Wistar rats (total n = 127. Anesthesia was induced by isoflurane (2.5-3% and maintained by fentanyl and midazolam during CPB. After catheterization of the left femoral artery, carotid artery and the right atrium, normothermic extracorporeal circulation was instituted for 60 minutes. In the first part of the study animals were euthanized after either 1 hour, 1 day, 2 or 5 days of the recovery period. In second part of the study animals were euthanized after 1 day of postoperative period. We evaluated the contractile response to phenylephrine (mesenteric arteries or to serotonin (coronary artery and vasodilatory response to acethylcholine (both arteries. RESULTS: Contractile responses to phenylephrine were reduced at 1 day recovery after CPB and Sham as compared to healthy control animals (Emax, mN: 7.9 ± 1.9, 6.5 ± 1.5, and 11.3 ± 1.3, respectively. Mainly FTY720, but not SEW2871, caused lymphopenia in both Sham and CPB groups. In coronary and mesenteric arteries, both FTY720 and SEW2871 normalized serotonin and phenylephrine-mediated vascular reactivity after CPB (p<0.05 and FTY720 increased relaxation to acetylcholine as compared with untreated rats that underwent CPB. CONCLUSION: Pretreatment with FTY720 or SEW2871 preserves vascular function in mesenteric and coronary artery after CPB. Therefore, pharmacological activation of S1P1 receptors may provide a promising therapeutic intervention to prevent CPB-related vascular dysfunction in patients.

  13. Effect of upper body position on arterial stiffness: influence of hydrostatic pressure and autonomic function.

    Science.gov (United States)

    Schroeder, Elizabeth C; Rosenberg, Alexander J; Hilgenkamp, Thessa I M; White, Daniel W; Baynard, Tracy; Fernhall, Bo

    2017-12-01

    To evaluate changes in arterial stiffness with positional change and whether the stiffness changes are due to hydrostatic pressure alone or if physiological changes in vasoconstriction of the conduit arteries play a role in the modulation of arterial stiffness. Thirty participants' (male = 15, 24 ± 4 years) upper bodies were positioned at 0, 45, and 72° angles. Pulse wave velocity (PWV), cardio-ankle vascular index, carotid beta-stiffness index, carotid blood pressure (cBP), and carotid diameters were measured at each position. A gravitational height correction was determined using the vertical fluid column distance (mmHg) between the heart and carotid artery. Carotid beta-stiffness was calibrated using three methods: nonheight corrected cBP of each position, height corrected cBP of each position, and height corrected cBP of the supine position (theoretical model). Low frequency systolic blood pressure variability (LFSAP) was analyzed as a marker of sympathetic activity. PWV and cardio-ankle vascular index increased with position (P hydrostatic pressure. Arterial stiffness indices based on Method 2 were not different from Method 3 (P = 0.65). LFSAP increased in more upright positions (P pressure did not (P > 0.05). Arterial stiffness increases with a more upright body position. Carotid beta-stiffness needs to be calibrated accounting for hydrostatic effects of gravity if measured in a seated position. It is unclear why PWV increased as this increase was independent of blood pressure. No difference between Methods 2 and 3 presumably indicates that the beta-stiffness increases are only pressure dependent, despite the increase in vascular sympathetic modulation.

  14. Arterial scan versus radiographic angiography in detection of shallow arterial ulcers

    International Nuclear Information System (INIS)

    Pollak, E.W.; Webber, M.M.; Cragin, M.D.; Wolfman, E.F. Jr.

    1977-01-01

    A comparison of 99m-technetium albumin aggregated arterial scan and radiographic angiography for detection of shallow intimal carotid artery ulcerations was made in a series of 12 anesthetized dogs, having a total of 16 acute arterial ulcerations. Radiographic angiography showed positive findings related to presence of stenosis or mural thrombosis in 12 instances. Direct visualization of ulceration was only exceptionally encountered. Arterial scan detected 14 of 16 intimal ulcers. The radionuclide method was reliable even in absence of stenosis or when only minimal mural thrombosis was present. Moreover, autopsy scan of the isolated arterial segments detected all 16 intimal lesions. These results indicate that the arterial scan was a more reliable method for detection of shallow arterial ulcers in this experimental model than radiographic angiography, especially when arterial lumen stenosis or mural thrombosis was minimal or absent

  15. Coexistence of Single Coronary Artery Anomaly and Aortic Arch Anomaly

    Directory of Open Access Journals (Sweden)

    Yilmaz Omur Otlu

    2014-03-01

    Full Text Available A 74-year-old male patient was admitted to our hospital for evaluation of recent onset atypical chest pain. His medical history included hypertension, dislipidemia and smoking. Physical examination was unremarkable. The resting electrocardiogram was demonstrated biphasic T waves on lateral derivations. Transthoracic echocardiography showed normal left and right ventricular dimensions and functions. Coronary angiography was planned for the patient. First, right transradial approach tried; but guidewire could not be advanced to ascendig aorta. Coronary angiography was performed through the right femoral artery. Multiple attempts to cannulate the left coronary ostium were unsuccessful. The right coronary artery cannulated from its normal ostium in the right sinus of Valsalva. After a very short common main stem, the artery divided into a right coronary artery, and separate left anterior descending artery and circumflex artery (Figure A. The coronary arteries were normal without any significant stenosis and any extrinsic compression. An aortic root injection confirmed the absence of left coronary ostium. Also, a retroesophageal right subclavian artery originating from the left aortic arch (arteria lusoria was detected as the last branch of aortic arch on contrast enhanced computerized tomography (Figure B-C. The patient discharged with medical teraphy.

  16. Prediction of parent artery of anterior communicating artery aneurysm on CT angiography

    International Nuclear Information System (INIS)

    Chung, Jin Young; Han, Tae Il; Kim, Dae Hong; Han, Hyun Young; Kim, Hyun Jung; Song, Mun Kab

    1999-01-01

    To determine whether CT angiography can predict the parent artery of an anterior communicating aneurysm on the basis of characteristics of the aneurysm and precommunication anterior cerebral artery. Eighteen patients with anterior communication aneurysm were studied prospectively using CT angiography and conventional angiography. The parent artery of an aneurysm was predicted by evaluating aneurysm neck location, direction of aneurysm projection, and size of the precommunicating anterior cerebral artery, as seen on CT angiography. A somatom Plus-4 spiral CT scanner was used and shaded-surface display three-dimensional images were constructed. Aneurysm neck was located near the parent artery in 12 cases(66.7%), and aneurysm projection was against the parent artery in 11 cases(61.1%). The parent artery of the anterior cerebral artery was larger in 15 cases(83.3%), including ten cases of hypoplasia or agenesis of the contralateral anterior cerebral artery. In 17 of 18 aneurysms(94.4%) the parent artery seen on DSA was correctly predicted by CT angiography. The parent artery of an anterior communicating aneurysm can be predicted by evaluating aneurysm neck location, direction of aneurysm projection, and precommunicating anterior cerebral artery, as seen on CT angiography

  17. Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, Marcus; Hack, Nicolas; Hahn, Klaus; Tiling, Reinhold; Jakobs, Tobias; Nikolaou, Konstantin; Becker, Christoph; Reiser, Maximilian; Ziegler, Franz von; Knez, Andreas; Koenig, Andreas; Klauss, Volker

    2007-01-01

    The aim of this study was to evaluate spiral multidetector computed tomography (MDCT) angiography using 64-slice technique in the detection of functionally relevant coronary artery stenoses (CAS). Thirty-eight patients (62±11 years, 28 men) with stable angina (26 with suspected and 12 with known coronary artery disease) were investigated using 64-slice MDCT angiography and gated myocardial perfusion SPECT (gated SPECT); a subgroup of 30 patients had additional invasive coronary angiography (ICA). Stenoses with luminal narrowing of ≥50% were defined as ''significant'' in MDCT angiography and ICA. MDCT angiography was compared with gated SPECT and the combination of gated SPECT plus ICA with respect to the detection of functionally relevant CAS. The sensitivity, specificity and negative and positive predictive values of MDCT angiography in detecting reversible perfusion defects on gated SPECT were 63%, 80%, 94% and 32%, respectively, in vessel-based analysis and 71%, 62%, 72% and 60%, respectively, in patient-based analysis. If only reversible perfusion defects on gated SPECT with CAS ≥50% on ICA were considered, the sensitivity, specificity and negative and positive predictive values were, respectively, 85%, 79%, 98% and 33% for vessel-based analysis and 85%, 59%, 83% and 61% for patient-based analysis. Sixty-four slice MDCT angiography failed to predict the functional relevance of CAS, but had a high negative predictive value in the exclusion of functionally relevant CAS in symptomatic patients. (orig.)

  18. Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, Marcus; Hack, Nicolas; Hahn, Klaus; Tiling, Reinhold [Ludwig-Maximilians-University, Department of Nuclear Medicine, Munich (Germany); Jakobs, Tobias; Nikolaou, Konstantin; Becker, Christoph; Reiser, Maximilian [Ludwig-Maximilians-University, Department of Clinical Radiology, Munich (Germany); Ziegler, Franz von; Knez, Andreas [Ludwig-Maximilians-University, Department of Cardiology, Klinikum Grosshadern, Munich (Germany); Koenig, Andreas; Klauss, Volker [Ludwig-Maximilians-University, Department of Cardiology, Medizinische Poliklinik-Innenstadt, Munich (Germany)

    2007-01-15

    The aim of this study was to evaluate spiral multidetector computed tomography (MDCT) angiography using 64-slice technique in the detection of functionally relevant coronary artery stenoses (CAS). Thirty-eight patients (62{+-}11 years, 28 men) with stable angina (26 with suspected and 12 with known coronary artery disease) were investigated using 64-slice MDCT angiography and gated myocardial perfusion SPECT (gated SPECT); a subgroup of 30 patients had additional invasive coronary angiography (ICA). Stenoses with luminal narrowing of {>=}50% were defined as ''significant'' in MDCT angiography and ICA. MDCT angiography was compared with gated SPECT and the combination of gated SPECT plus ICA with respect to the detection of functionally relevant CAS. The sensitivity, specificity and negative and positive predictive values of MDCT angiography in detecting reversible perfusion defects on gated SPECT were 63%, 80%, 94% and 32%, respectively, in vessel-based analysis and 71%, 62%, 72% and 60%, respectively, in patient-based analysis. If only reversible perfusion defects on gated SPECT with CAS {>=}50% on ICA were considered, the sensitivity, specificity and negative and positive predictive values were, respectively, 85%, 79%, 98% and 33% for vessel-based analysis and 85%, 59%, 83% and 61% for patient-based analysis. Sixty-four slice MDCT angiography failed to predict the functional relevance of CAS, but had a high negative predictive value in the exclusion of functionally relevant CAS in symptomatic patients. (orig.)

  19. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension

    International Nuclear Information System (INIS)

    Eisenberg, B.M.; Linss, G.

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.) [de

  20. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Yoon [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Severance Hospital, Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Seoul (Korea, Republic of); Kim, Chan Kyo; Park, Byung Kwan [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Kim, EunJu [Philips Healthcare Korea, Seoul (Korea, Republic of)

    2014-09-13

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88 % of right and 92 % of left renal arteries, while it was 96 % in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82 % and 100 % for reader 1 and 82 % and 95 % for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. (orig.)

  1. Bronchial arteries: an arteriosclerosis-resistant circulation.

    Science.gov (United States)

    Kotoulas, Christophoros; Melachrinou, Maria; Konstantinou, George N; Alexopoulos, Dimitrios; Dougenis, Dimitrios

    2010-01-01

    Until now, it is unknown whether and to what extent arteriosclerotic disease affects the bronchial arteries. We conducted this pilot study to estimate the prevalence of arteriosclerosis of the bronchial arteries, to correlate it with certain clinicolaboratory arteriosclerotic parameters or any coexistent coronary artery disease (CAD) and to validate the clinical significance. Bronchial arteries 10-15 mm long were obtained from 40 patients with a mean age of 62.3 years who underwent major thoracic procedures. Their medical history and detailed clinical and laboratory arteriosclerotic risk factors were documented. The mean diameter of bronchial artery specimens was 0.97 mm. Histology revealed medial calcific sclerosis only in 1 patient (2.5%) without simultaneous, established atherosclerotic lesions or narrowing of the lumen. Furthermore, the vessel diameter was significantly correlated not only with the advanced stage of the disease (p = 0.031), but also with the proximal occlusion of the bronchial tree (p = 0.042). We noted a marginally not significant correlation between arteriosclerosis and metabolic syndrome (p = 0.075), independent from a history of CAD (p = 0.84). Bronchial arteries exhibit only medial calcific sclerosis. CAD and chronic obstructive pulmonary disease do not seem to affect them in terms of atherosclerotic alteration findings or vessel diameter changes. The bronchial resistance to arteriosclerosis might support the mediastinal status quo through their anastomoses, contributing to all its structures, and might be indirect evidence of a different physiological function of the bronchial endothelium, which needs to be further investigated. Copyright 2009 S. Karger AG, Basel.

  2. Double profunda brachii artery

    OpenAIRE

    Gavishiddappa A Hadimani; Jyoti V Hadimani; Ishwar B Bagoji; Shardha Bai Rathod; Balappa M Bannur

    2016-01-01

    Brachial artery (BA) is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii...

  3. Anomalous external carotid artery-internal carotid artery anastomosis in two patients with proximal internal carotid arterial remnants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hun [Dept. of Neurology, Stroke Center, Myongji Hospital, Goyang (Korea, Republic of); Cho, Young Dae; Kang, Hyun Seung; Kim, Jeong Eun; Han, Moon Hee [Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seung Chai [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Ahn, Jun Hyong [Dept. of Neurosurgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of)

    2015-08-15

    Two angiographic instances of anomalous external carotid artery (ECA) and internal carotid artery (ICA) anastomosis are described, each occurring at the C2-3 level and bearing remnants of proximal ICA. The ICA remnant of one patient (identifiable immediately upon bifurcation of the common carotid artery) was hypoplastic, and that of the other patient was an occluded arterial stump. These features are not typical of non-bifurcating ICA. The occipital artery originated from an anomalous connection in one instance and from the main trunk of the ECA (just past the ECA-ICA connection) in the other.

  4. Pulmonary artery and right ventricle assessment in pulmonary hypertension. Correlation between functional parameters of ECG-gated CT and right-side heart catheterization

    International Nuclear Information System (INIS)

    Abel, Elodie; Jankowski, Adrien; Pison, Christophe; Bosson, Jean Luc; Bouvaist, Helene; Ferretti, Gilbert R.

    2012-01-01

    Background: Right ventricular function predicts outcome in patients with pulmonary hypertension (PH). Therefore accurate assessment of right ventricular function is essential to graduate severity, assess follow-up, and response to therapy. Purpose: To evaluate whether PH severity could be assessed using electrocardiography-gated CT (ECG-gated CT) functional parameters. A further objective was to evaluate cardiac output (CO) using two ECG-gated CT methods: the reference Simpson technique and the fully automatic technique generated by commercially available cardiac software. Material and Methods: Our institutional review board approved this study; patient consent was not required. Twenty-seven patients who had undergone ECG-gated CT and right heart catheterization (RHC) were included. Two independent observers measured pulmonary artery (PA) diameter, PA distensibility, aorta diameter, right ventricular cardiac output (CT-RVCO) and right ventricular ejection fraction (CT-RVEF) with automatic and Simpson techniques on ECG-gated CT. RHC-CO and mean pulmonary arterial pressure (mPAP) were measured on RHC. Relationship between ECG-gated CT and RHC measurements was tested with linear regression analysis. Results: Inter-observer agreement was good for all measurements (r > 0.7) except for CT-RVCO calculated with Simpson's technique (r = 0.63). Pulmonary artery (PA) distensibility was significantly correlated to mPAP (r = -0.426, P = 0.027). CT-RVEF was correlated with mPAP only when issued from Simpson technique (r = -0.417, P = 0.034). CT-RVEF was not significantly correlated to RHC-CO (P > 0.2). CT-RVCO measured with Simpson technique (r = 0.487, P = 0.010) and automatic segmentation (r = 0.549, P 0.005) correlated equally with RHC-CO. Conclusion: CT-RVEF and CT-RVCO measured on ECG-gated CT are significantly correlated, respectively, to mPAP and RHC-CO in this population with severe reduction of the right ventricular ejection fraction and could be useful for evaluating

  5. The importance of the ligation of the inferior thyroid artery in parathyroid function after subtotal thyroidectomy

    Directory of Open Access Journals (Sweden)

    Araujo Filho Vergilius José Furtado de

    2000-01-01

    Full Text Available We prospectively studied the effects of the ligation of the inferior thyroid artery (ITA on postoperative hypoparathyroidism in 48 patients who underwent functional subtotal thyroidectomy. Patients were randomized into two groups: A, with bilateral ligation of the ITA and B, without ligation of the ITA. Parathyroid function was checked preoperatively and after surgery by clinical examination and measurement of total calcium, intact PTH, urinary calcium, and AMPc. RESULTS: A significant incidence of postoperative hypocalcemia occurred: 17% in group A and 13% in B on the 4th postoperative day. Six months later, the incidence was 5% in Group A and 0% in Group B. These differences were not statistically significant between the two groups, and neither were any of the other clinical and laboratory observations. CONCLUSION: The ligation of the ITA was not an important causal factor for the occurrence of postoperative hypocalcemia after subtotal thyroidectomy.

  6. Distal Embolic Protection for Renal Arterial Interventions

    International Nuclear Information System (INIS)

    Dubel, Gregory J.; Murphy, Timothy P.

    2008-01-01

    Distal or embolic protection has intuitive appeal for its potential to prevent embolization of materials generated during interventional procedures. Distal protection devices (DPDs) have been most widely used in the coronary and carotid vascular beds, where they have demonstrated the ability to trap embolic materials and, in some cases, to reduce complications. Given the frequency of chronic kidney disease in patients with renal artery stenosis undergoing stent placement, it is reasonable to propose that these devices may play an important role in limiting distal embolization in the renal vasculature. Careful review of the literature reveals that atheroembolization does occur during renal arterial interventions, although it often goes undetected. Early experience with DPDs in the renal arteries in patients with suitable anatomy suggests retrieval of embolic materials in approximately 71% of cases and renal functional improvement/stabilization in 98% of cases. The combination of platelet inhibition and a DPD may provide even greater benefit. Given the critical importance of renal functional preservation, it follows that everything that can be done to prevent atheroembolism should be undertaken including the use of DPDs when anatomically feasible. The data available at this time support a beneficial role for these devices

  7. Response sensitivity of barrel neuron subpopulations to simulated thalamic input.

    Science.gov (United States)

    Pesavento, Michael J; Rittenhouse, Cynthia D; Pinto, David J

    2010-06-01

    Our goal is to examine the relationship between neuron- and network-level processing in the context of a well-studied cortical function, the processing of thalamic input by whisker-barrel circuits in rodent neocortex. Here we focus on neuron-level processing and investigate the responses of excitatory and inhibitory barrel neurons to simulated thalamic inputs applied using the dynamic clamp method in brain slices. Simulated inputs are modeled after real thalamic inputs recorded in vivo in response to brief whisker deflections. Our results suggest that inhibitory neurons require more input to reach firing threshold, but then fire earlier, with less variability, and respond to a broader range of inputs than do excitatory neurons. Differences in the responses of barrel neuron subtypes depend on their intrinsic membrane properties. Neurons with a low input resistance require more input to reach threshold but then fire earlier than neurons with a higher input resistance, regardless of the neuron's classification. Our results also suggest that the response properties of excitatory versus inhibitory barrel neurons are consistent with the response sensitivities of the ensemble barrel network. The short response latency of inhibitory neurons may serve to suppress ensemble barrel responses to asynchronous thalamic input. Correspondingly, whereas neurons acting as part of the barrel circuit in vivo are highly selective for temporally correlated thalamic input, excitatory barrel neurons acting alone in vitro are less so. These data suggest that network-level processing of thalamic input in barrel cortex depends on neuron-level processing of the same input by excitatory and inhibitory barrel neurons.

  8. Effects of glucagon-like peptide-1 on endothelial function in type 2 diabetes patients with stable coronary artery disease

    DEFF Research Database (Denmark)

    Nyström, Thomas; Gutniak, Mark K; Zhang, Qimin

    2004-01-01

    GLP-1 stimulates insulin secretion, suppresses glucagon secretion, delays gastric emptying, and inhibits small bowel motility, all actions contributing to the anti-diabetogenic peptide effect. Endothelial dysfunction is strongly associated with insulin resistance and type 2 diabetes mellitus...... and may cause the angiopathy typifying this debilitating disease. Therefore, interventions affecting both endothelial dysfunction and insulin resistance may prove useful in improving survival in type 2 diabetes patients. We investigated GLP-1's effect on endothelial function and insulin sensitivity (S......(I)) in two groups: 1) 12 type 2 diabetes patients with stable coronary artery disease and 2) 10 healthy subjects with normal endothelial function and S(I). Subjects underwent infusion of recombinant GLP-1 or saline in a random crossover study. Endothelial function was measured by postischemic FMD of brachial...

  9. TART input manual

    International Nuclear Information System (INIS)

    Kimlinger, J.R.; Plechaty, E.F.

    1982-01-01

    The TART code is a Monte Carlo neutron/photon transport code that is only on the CRAY computer. All the input cards for the TART code are listed, and definitions for all input parameters are given. The execution and limitations of the code are described, and input for two sample problems are given

  10. Chest pain in patients with arterial hypertension, angiographically normal coronary arteries and stiff aorta: the aortic pain syndrome.

    Science.gov (United States)

    Stakos, Dimitrios A; Tziakas, Dimitrios N; Chalikias, George; Mitrousi, Konstantina; Tsigalou, Christina; Boudoulas, Harisios

    2013-01-01

    Arterial hypertension is often associated with a stiff aorta as a result of collagen accumulation in the aortic wall and may produce chest pain. In the present study, possible interrelationships between aortic function, collagen turnover and exercise-induced chest pain in patients with arterial hypertension and angiographically normal coronary arteries were investigated. Ninety-seven patients with arterial hypertension, angiographically normal coronary arteries and no evidence of myocardial ischemia on nuclear cardiac imaging during exercise test were studied. Of these, 43 developed chest pain during exercise (chest pain group) while 54 did not (no chest pain group). Carotid femoral pulse-wave velocity (PWVc-f) was used to assess the elastic properties of the aorta. Amino-terminal pro-peptides of pro-collagen type I, (PINP, reflecting collagen synthesis), serum telopeptides of collagen type I (CITP, reflecting collagen degradation), pro-metalloproteinase 1 (ProMMP-1), and tissue inhibitor of metalloproteinase 1 (TIMP-1, related to collagen turnover) were measured in plasma by immunoassay. The chest pain group had higher PWVc-f, higher and /CITP ratio, and lower proMMP-1/ TIMP-1 ratio compared to the no chest pain group. PWVc-f (t=2.53, p=0.02) and PINP (t=2.42, p=0.02) were independently associated with the presence of chest pain in multiple regression analysis. Patients with arterial hypertension, exercise-induced chest pain and angiographically normal coronary arteries, without evidence of exercise-induced myocardial ischemia, had a stiffer aorta compared to those without chest pain. Alterations in collagen type I turnover that favor collagen accumulation in the aortic wall may contribute to aortic stiffening and chest pain in these patients.

  11. Association between internal carotid artery dissection and arterial tortuosity

    International Nuclear Information System (INIS)

    Saba, Luca; Piga, Mario; Argiolas, Giovanni Maria; Siotto, Paolo; Sumer, Suna; Wintermark, Max; Raz, Eytan; Sanfilippo, Roberto; Montisci, Roberto

    2015-01-01

    Carotid artery dissection is an important cause of ischemic stroke in all age groups, particularly in young patients. The purpose of this work was to assess whether there is an association between the presence of an internal carotid artery dissection (ICAD) and the arterial tortuosity. This study considered 124 patients (72 males and 52 females; median age 57 years) with CT/MR diagnosis of ICAD of the internal carotid artery were considered in this multi-centric retrospective study. The arterial tortuosity was evaluated and, when present, was categorized as elongation, kinking, or coiling. For each patient, both the right and left sides were considered for a total number of 248 arteries in order to have the same number of cases and controls. Fisher's exact test was applied to test the association between elongation, kinking, coiling, dissection, and the side affected by CAD. Fisher's exact test showed a statistically significant association between the ICAD and kinking (p = 0.0089) and coiling (p = 0.0251) whereas no statistically significant difference was found with arterial vessel elongation (p = 0.444). ICAD was more often seen on the left side compared to the right (p = 0.0001). These results were confirmed using both carotid arteries of the same patient as dependent parameter with p = 0.0012, 0.0129, and 0.3323 for kinking, coiling, and elongation, respectively. The presence of kinking and coiling is associated with ICAD. (orig.)

  12. Association between internal carotid artery dissection and arterial tortuosity

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Piga, Mario [Azienda Ospedaliero Universitaria (A.O.U.), Department of Radiology, Monserrato, Cagliari (Italy); Argiolas, Giovanni Maria; Siotto, Paolo [Azienda Ospedaliero Brotzu (A.O.B.), Department of Radiology, di Cagliari (Italy); Sumer, Suna; Wintermark, Max [Neuroradiology Division, Neuroradiology, UVA Department of Radiology, Charlottesville, VA (United States); Raz, Eytan [New York University School of Medicine, Department of Radiology, New York, NY (United States); Sapienza University of Rome, Department of Neurology and Psychiatry, Rome (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria (A.O.U.), Department of Vascular Surgery, di Cagliari (Italy)

    2014-10-18

    Carotid artery dissection is an important cause of ischemic stroke in all age groups, particularly in young patients. The purpose of this work was to assess whether there is an association between the presence of an internal carotid artery dissection (ICAD) and the arterial tortuosity. This study considered 124 patients (72 males and 52 females; median age 57 years) with CT/MR diagnosis of ICAD of the internal carotid artery were considered in this multi-centric retrospective study. The arterial tortuosity was evaluated and, when present, was categorized as elongation, kinking, or coiling. For each patient, both the right and left sides were considered for a total number of 248 arteries in order to have the same number of cases and controls. Fisher's exact test was applied to test the association between elongation, kinking, coiling, dissection, and the side affected by CAD. Fisher's exact test showed a statistically significant association between the ICAD and kinking (p = 0.0089) and coiling (p = 0.0251) whereas no statistically significant difference was found with arterial vessel elongation (p = 0.444). ICAD was more often seen on the left side compared to the right (p = 0.0001). These results were confirmed using both carotid arteries of the same patient as dependent parameter with p = 0.0012, 0.0129, and 0.3323 for kinking, coiling, and elongation, respectively. The presence of kinking and coiling is associated with ICAD. (orig.)

  13. Normal variation of hepatic artery

    International Nuclear Information System (INIS)

    Kim, Inn; Nam, Myung Hyun; Rhim, Hyun Chul; Koh, Byung Hee; Seo, Heung Suk; Kim, Soon Yong

    1987-01-01

    This study was an analyses of blood supply of the liver in 125 patients who received hepatic arteriography and abdominal aortography from Jan. 1984 to Dec. 1986 at the Department of Radiology of Hanyang University Hospital. A. Variations in extrahepatic arteries: 1. The normal extrahepatic artery pattern occurred in 106 of 125 cases (84.8%) ; Right hepatic and left hepatic arteries arising from the hepatic artery proper and hepatic artery proper arising from the common hepatic artery. 2. The most common type of variation of extrahepatic artery was replaced right hepatic artery from superior mesenteric artery: 6 of 125 cases (4.8%). B. Variations in intrahepatic arteries: 1. The normal intrahepatic artery pattern occurred in 83 of 125 cases (66.4%). Right hepatic and left hepatic arteries arising from the hepatic artery proper and middle hepatic artery arising from lower portion of the umbilical point of left hepatic artery. 2. The most common variation of intrahepatic arteries was middle hepatic artery. 3. Among the variation of middle hepatic artery; Right, middle and left hepatic arteries arising from the same location at the hepatic artery proper was the most common type; 17 of 125 cases (13.6%)

  14. Blood flows in the maxillocarotid anastomoses and internal carotid artery of conscious dogs.

    Science.gov (United States)

    Lee, M C; Reid, I A; Ramsay, D J

    1986-06-01

    Although the external carotid artery is known to contribute to the cerebral blood flow in anesthetized dogs, quantitative information on the anastomoses and their role in conscious dogs is lacking. This study was carried out to determine blood flows in these anastomoses and the internal carotid artery, and also to examine the functional significance of the anastomoses in conscious dogs. Fifteen-micron radioactive microspheres were injected into common and external carotid arteries of four conscious dogs through chronically implanted catheters. Blood flows were determined by the reference sample method and by comparing microsphere distributions in the brain and the masseter muscle. Blood flows were estimated to be 140 +/- 32, 7.7 +/- 1.4, and 3.3 +/- 1.1 ml/minute (mean +/- SD) in the common carotid artery, internal carotid artery, and anastomoses on each side, respectively. Additional evidence indicated that the anastomotic flow so determined was primarily the flow in the anastomotic artery. Humoral responses to angiotensin II infusions were also studied in conscious dogs. External carotid angiotensin increased plasma 11-hydroxycorticosteroid concentration (used as an index of ACTH secretion) but did not increase plasma vasopressin concentration to the same extent as common carotid infusion. Therefore, the external carotid artery is functionally important in perfusing the brain in conscious dogs.

  15. Massive cerebral arterial air embolism following arterial catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.W. [Northwestem University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Yang, B.P. [Northwestern University Feinberg School of Medicine, Department of Neurological Surgery, Chicago, IL (United States)

    2005-12-01

    Microscopic cerebral arterial air embolism (CAAE) has been described in many patients undergoing cardiac surgery as well as other invasive diagnostic and therapeutic procedures. However, massive CAAE is rare. We report a 42-year-old woman who initially presented with thalamic and basal ganglia hemorrhages. Shortly after a radial arterial catheter was inserted, the patient suffered a generalized seizure and CT demonstrated intra-arterial air in bilateral cerebral hemispheres. (orig.)

  16. Reconstruction of Traumatic External Iliac Artery Dissection Due to Vascular Clamping.

    Science.gov (United States)

    Kırnap, Mahir; Özçelik, Ümit; Akdur, Aydıncan; Ayvazoğlu Soy, Ebru H; Işıklar, İclal; Yarbuğ Karakayalı, Feza; Moray, Gökhan; Haberal, Mehmet

    2017-10-31

    Traumatic external iliac artery dissection after renal transplant is a rare complication, but it should be urgently managed due to its devastating effects on graft and lower limb circulation. External iliac artery dissection is seen more in recipients with diabetes mellitus and comorbid disease. Recipients with external iliac artery dissection should be treated immediately by percutaneus angioplasty or surgical reconstruction. In this study, we reported the management of 2 kidney transplant cases with external iliac artery dissection due to vascular clamping of the artery. External iliac artery dissection was diagnosed by ultrasonography in both cases. After failed percutaneous interventional angioplasty, we reconstructed the external iliac artery dissection surgically and replaced the external iliac artery with polytetra-fluoroethylene grafts in both patients. Both patients were discharged with normal functioning grafts showing 0.9 and 0.8 mg/dL serum creatinine levels at month 3 posttransplant. Close monitoring of recipients after transplant is mandatory for early diagnosis and early management of external iliac artery dissection to prevent graft loss and preserve lower limb circulation. Routine Doppler ultrasonography is an inexpensive and useful tool for early diagnosis in cases of sudden cessation or decrease in urine. In cases of failed percutaneous interventional angioplasty, reconstruction with synthetic vascular grafts can be safely applied in external iliac artery dissection.

  17. Sound effects: Multimodal input helps infants find displaced objects.

    Science.gov (United States)

    Shinskey, Jeanne L

    2017-09-01

    sensitive to bimodal input as multisensory functions develop across the first year. © 2016 The British Psychological Society.

  18. Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    Science.gov (United States)

    Natsume, Takahiro; Ishida, Masaki; Kitagawa, Kakuya; Nagata, Motonori; Sakuma, Hajime; Ichihara, Takashi

    2015-11-01

    The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models requires faithful recording of contrast content in the blood and myocardium. Typically, the arterial input function (AIF) is obtained by setting a region of interest in the left ventricular cavity. However, there is a small delay between the AIF and the myocardial curves, and such time discrepancies can lead to errors in flow estimation using Patlak plot analysis. In this study, the time discrepancies between the arterial TSI curve and the myocardial tissue TSI curve were estimated based on the compartment model. In the early phase after the arrival of the contrast agent in the myocardium, the relationship between rate constant K1 and the concentrations of Gd-DTPA contrast agent in the myocardium and arterial blood (LV blood) can be described by the equation K1={dCmyo(tpeak)/dt}/Ca(tpeak), where Cmyo(t) and Ca(t) are the relative concentrations of Gd-DTPA contrast agent in the myocardium and in the LV blood, respectively, and tpeak is the time corresponding to the peak of Ca(t). In the ideal case, the time corresponding to the maximum upslope of Cmyo(t), tmax, is equal to tpeak. In practice, however, there is a small difference in the arrival times of the contrast agent into the LV and into the myocardium. This difference was estimated to correspond to the difference between tpeak and tmax. The magnitudes of such time discrepancies and the effectiveness of the correction for these time discrepancies were measured in 18 subjects who underwent myocardial perfusion MRI under rest and stress conditions. The effects of the time discrepancies could be corrected effectively in the myocardial perfusion estimates. Copyright © 2015 Elsevier Inc. All rights

  19. Left Ventricular Function after Arterial Switch Operation as Assessed by Two-Dimensional Speckle-Tracking Echocardiography in Patients with Simple Transposition of the Great Arteries.

    Science.gov (United States)

    Malakan Rad, Elaheh; Ghandi, Yazdan; Kocharian, Armen; Mirzaaghayan, Mohammadreza

    2016-07-06

    Background: The late postoperative course for children with transposition of the great arteries (TGA) with an intact ventricular septum (IVS) is very important because the coronary arteries may be at risk of damage during arterial switch operation (ASO). We sought to investigate left ventricular function in patients with TGA/IVS by echocardiography. Methods: From March 2011 to December 2012, totally 20 infants (12 males and 8 females) with TGA/IVS were evaluated via 2-dimensional speckle-tracking echocardiography (2D STE) more than 6 months after they underwent ASO. A control group of age-matched infants and children was also studied. Left ventricular longitudinal strain (S), strain rate (SR), time to peak systolic longitudinal strain (TPS), and time to peak systolic longitudinal strain rate (TPSR) were measured and compared between the 2 groups. Results: Mean ± SD of age at the time of study in the patients with TGA/IVS was 15 ± 5 months, and also age at the time of ASO was 12 ± 3 days. Weight was 3.13 ± 0.07 kg at birth and 8.83 ± 1.57 kg at the time of ASO. Global strain (S), Time to peak strain rate (TPSR), and Time to peak strain (TPS) were not significantly different between the 2 groups, whereas global strain rate (SR) was significantly different (p value < 0.001). In the 3-chamber view, the values of S in the lateral, septal, inferior, and anteroseptal walls were significantly different between the 2 groups (p value < 0.001), and SR in the posterior wall was significantly different between the 2 groups (p value < 0.001). There were no positive correlations between S and SR in terms of the variables of heart rate, total cardiopulmonary bypass time, and aortic cross-clamp time. There were no statistically significant differences between the 2 groups regarding S, SR, TPS, and TPSR in the anteroseptal and posterior walls in the 3-chamber view and in the lateral and septal walls in the 4-chamber view. Conclusion: We showed that between 6 and 18 months after

  20. Interventional treatment of renal artery stenosis: a mid-term evaluation of clinical efficacy

    International Nuclear Information System (INIS)

    Liu Jing; Zhang Xitong

    2009-01-01

    Objective: To assess the clinical efficacy of interventional management for the treatment of renal artery stenosis. Methods: Percutaneous transluminal balloon renal angioplasty and / or percutaneous transluminal renal artery stenting were performed in 47 patients with renal artery stenosis (55 stenosed arteries in total). A follow-up study on the blood pressure and renal function was conducted and the results were statistically analyzed. Results: Fifty-four stenosed renal arteries were successfully reopened, of which only percutaneous transluminal balloon angioplasty was adopted in 17 and percutaneous transluminal renal artery stenting in 37. One patient died during the procedure. A follow-up for a mean period of (2.5 ± 0.6) years was carried out. The blood pressure determined at one (n = 46), 6 (n = 46), 12 (n = 33) and 24 (n = 29) months after the treatment was significantly decreased when compared to that determined before the treatment (P < 0.01). The clinical effective rate was 89.13% (41 / 46), 72.73% (24 / 33) and 62.07% (18 / 29), respectively. After the therapy,the renal function was improved in 5, remained unchanged in 33 and became worse in 3 patients. The comparison of the post-operative renograms (obtained within 2 months) with the pre-operative ones showed that in eight patients there was an increase in renal blood flow with an improvement in renal function impairment, which took a turn from severe degree to mild or moderate degree. Nevertheless, severe impairment in renal blood flow remained in 3 patients. Conclusion: Percutaneous transluminal balloon renal angioplasty and percutaneous transluminal renal artery stenting are safe and effective treatments for the renal artery stenosis, which also has a beneficial effect on the related renal hypertension and renal insufficiency. (authors)

  1. Popliteal artery entrapment syndrome

    International Nuclear Information System (INIS)

    Klooster, N.J.J.; Janevski, B.K.; Kitslaar, P.

    1988-01-01

    Two patients with unilateral popliteal artery entrapment syndrome (PAES) are reported. The importance of diligence in angiographic diagnosis and recognition of the so-called 'functional' PAES group as a separate entity are stressed. It is inferred from our material that a surgical approach for PAES is to be advocated since surgical release of the entrapment can lead to complete resolution of symptoms regardless of aetiology. (orig.) [de

  2. Coronary artery calcification is increased in patients with COPD and associated with increased morbidity and mortality

    DEFF Research Database (Denmark)

    Williams, M. C.; Murchison, J. T.; Edwards, L. D.

    2014-01-01

    Background Coronary artery calcification is pathognomonic of coronary artery disease (CAD). Whether CAD in patients with COPD is linked to lung function, functional capacity and/or clinically relevant outcomes is unknown. The objective was to assess the association between CAD and disease severit...

  3. IFF, Full-Screen Input Menu Generator for FORTRAN Program

    International Nuclear Information System (INIS)

    Seidl, Albert

    1991-01-01

    1 - Description of program or function: The IFF-package contains input modules for use within FORTRAN programs. This package enables the programmer to easily include interactive menu-directed data input (module VTMEN1) and command-word processing (module INPCOM) into a FORTRAN program. 2 - Method of solution: No mathematical operations are performed. 3 - Restrictions on the complexity of the problem: Certain restrictions of use may arise from the dimensioning of arrays. Field lengths are defined via PARAMETER-statements

  4. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  5. MPC for LPV Systems Based on Parameter-Dependent Lyapunov Function with Perturbation on Control Input Strategy

    Directory of Open Access Journals (Sweden)

    Pornchai Bumroongsri

    2012-04-01

    Full Text Available In this paper, the model predictive control (MPC algorithm for linear parameter varying (LPV systems is proposed. The proposed algorithm consists of two steps. The first step is derived by using parameter-dependent Lyapunov function and the second step is derived by using the perturbation on control input strategy. In order to achieve good control performance, the bounds on the rate of variation of the parameters are taken into account in the controller synthesis. An overall algorithm is proved to guarantee robust stability. The controller design is illustrated with two case studies of continuous stirred-tank reactors. Comparisons with other MPC algorithms for LPV systems have been undertaken. The results show that the proposed algorithm can achieve better control performance.

  6. Phase-based vascular input function: Improved quantitative DCE-MRI of atherosclerotic plaques

    NARCIS (Netherlands)

    van Hoof, R. H. M.; Hermeling, E.; Truijman, M. T. B.; van Oostenbrugge, R. J.; Daemen, J. W. H.; van der Geest, R. J.; van Orshoven, N. P.; Schreuder, A. H.; Backes, W. H.; Daemen, M. J. A. P.; Wildberger, J. E.; Kooi, M. E.

    2015-01-01

    Purpose: Quantitative pharmacokinetic modeling of dynamic contrast-enhanced (DCE)-MRI can be used to assess atherosclerotic plaque microvasculature, which is an important marker of plaque vulnerability. Purpose of the present study was (1) to compare magnitude-versus phase-based vascular input

  7. Impact of regulation on English and Welsh water-only companies: an input-distance function approach.

    Science.gov (United States)

    Molinos-Senante, María; Porcher, Simon; Maziotis, Alexandros

    2017-07-01

    The assessment of productivity change over time and its drivers is of great significance for water companies and regulators when setting urban water tariffs. This issue is even more relevant in privatized water industries, such as those in England and Wales, where the price-cap regulation is adopted. In this paper, an input-distance function is used to estimate productivity change and its determinants for the English and Welsh water-only companies (WoCs) over the period of 1993-2009. The impacts of several exogenous variables on companies' efficiencies are also explored. From a policy perspective, this study describes how regulators can use this type of modeling and results to calculate illustrative X factors for the WoCs. The results indicate that the 1994 and 1999 price reviews stimulated technical change, and there were small efficiency gains. However, the 2004 price review did not accelerate efficiency change or improve technical change. The results also indicated that during the whole period of study, the excessive scale of the WoCs contributed negatively to productivity growth. On average, WoCs reported relatively high efficiency levels, which suggests that they had already been investing in technologies that reduce long-term input requirements with respect to exogenous and service-quality variables. Finally, an average WoC needs to improve its productivity toward that of the best company by 1.58%. The methodology and results of this study are of great interest to both regulators and water-company managers for evaluating the effectiveness of regulation and making informed decisions.

  8. The Features of Extrahepatic Collateral Arteries Related to Hepatic Artery Occlusion and Benefits in the Trans arterial Management of Liver Tumors

    International Nuclear Information System (INIS)

    Yang, L.; Zhang, X.M.; Ren, Y.J.; Miao, N.D.; Huang, X.H.; Dong, G.L.

    2013-01-01

    To investigate the extrahepatic collateral arteries related to hepatic artery occlusion (HAO) and to determine its benefits in the trans arterial management of liver tumors. Methods and Findings. Eleven patients (7 hepatocellular carcinomas, 3 liver metastases, and 1 with hemangioma) with HAO confirmed with digital subtraction angiography (DSA) were admitted to our hospital. Of the 11 patients, 7 were men and 4 were women, with an average age of 41.5 ± 15.5 years (range: 29 to 70 years). DSA was performed to evaluate the collateral routes to the liver. In the 11 patients with HAO, DSA showed complete occlusion of the common hepatic artery in 9 patients and the proper hepatic artery (PHA) in 2 patients. Extrahepatic collateral arteries supplying the liver were readily evident. The collateral arteries originated from the superior mesenteric artery (SMA) in 8 patients, from the gastroduodenal artery in 2 patients, and from the left gastric artery (LGA) in 1 patient. Transcatheter treatment was successfully performed via the collateral artery in all patients except the one who had hemangioma. Conclusions. DSA is an effective method for detecting collateral circulation related to HAO and may provide information to guide transcatheter management decisions.

  9. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function.

    Science.gov (United States)

    Park, Sung Yoon; Kim, Chan Kyo; Kim, EunJu; Park, Byung Kwan

    2015-02-01

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88% of right and 92% of left renal arteries, while it was 96% in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82% and 100% for reader 1 and 82% and 95% for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. • Accurate pre-treatment evaluation of renal artery anatomy helps clinical decision-making. • NC-MRA using RAVEL offers acceptable imaging quality for renal artery evaluation. • The 3 T RAVEL technique provides excellent diagnostic performance for renal artery evaluation. • The 3 T RAVEL technique may be an alternative to contrast-enhanced MRA.

  10. Machine Learning Techniques for Arterial Pressure Waveform Analysis

    Directory of Open Access Journals (Sweden)

    João Cardoso

    2013-05-01

    Full Text Available The Arterial Pressure Waveform (APW can provide essential information about arterial wall integrity and arterial stiffness. Most of APW analysis frameworks individually process each hemodynamic parameter and do not evaluate inter-dependencies in the overall pulse morphology. The key contribution of this work is the use of machine learning algorithms to deal with vectorized features extracted from APW. With this purpose, we follow a five-step evaluation methodology: (1 a custom-designed, non-invasive, electromechanical device was used in the data collection from 50 subjects; (2 the acquired position and amplitude of onset, Systolic Peak (SP, Point of Inflection (Pi and Dicrotic Wave (DW were used for the computation of some morphological attributes; (3 pre-processing work on the datasets was performed in order to reduce the number of input features and increase the model accuracy by selecting the most relevant ones; (4 classification of the dataset was carried out using four different machine learning algorithms: Random Forest, BayesNet (probabilistic, J48 (decision tree and RIPPER (rule-based induction; and (5 we evaluate the trained models, using the majority-voting system, comparatively to the respective calculated Augmentation Index (AIx. Classification algorithms have been proved to be efficient, in particular Random Forest has shown good accuracy (96.95% and high area under the curve (AUC of a Receiver Operating Characteristic (ROC curve (0.961. Finally, during validation tests, a correlation between high risk labels, retrieved from the multi-parametric approach, and positive AIx values was verified. This approach gives allowance for designing new hemodynamic morphology vectors and techniques for multiple APW analysis, thus improving the arterial pulse understanding, especially when compared to traditional single-parameter analysis, where the failure in one parameter measurement component, such as Pi, can jeopardize the whole evaluation.

  11. Framework for Modelling Multiple Input Complex Aggregations for Interactive Installations

    DEFF Research Database (Denmark)

    Padfield, Nicolas; Andreasen, Troels

    2012-01-01

    on fuzzy logic and provides a method for variably balancing interaction and user input with the intention of the artist or director. An experimental design is presented, demonstrating an intuitive interface for parametric modelling of a complex aggregation function. The aggregation function unifies...

  12. Penile artery shunt syndrome: a novel cause of erectile dysfunction after penile revascularization surgery.

    Science.gov (United States)

    Pavlinec, Jonathan G; Hakky, Tariq S; Yang, Christopher; Massis, Kamal; Munarriz, Ricardo; Carrion, Rafael E

    2014-09-01

    Penile revascularization is a surgical treatment option for erectile dysfunction (ED) in healthy individuals due to a focal arterial occlusion in the absence of generalized vascular disease. Most described failures have been attributed to graft stenosis or disruption of the anastomosis. We report a novel phenomenon called Penile Artery Shunt Syndrome that contributed to persistent ED in a patient after penile microvascular arterial bypass surgery. A 26-year-old man presented for evaluation of long-standing ED, which was attributed to trauma sustained 12 years earlier. He had difficulty obtaining and maintaining erections despite oral pharmacotherapy. Clinical data related to the case were studied, analyzed, and reviewed with urologic and radiologic specialists at multiple centers that collaborated in the care of this patient. Penile duplex ultrasound peak systolic velocities and five-item International Index for Erectile Function questionnaire scores were the main outcome measures. Initial diagnostic workup of the patient confirmed severe insufficiency of the left cavernosal artery, with no evidence of venous leak. The patient underwent penile microvascular arterial bypass surgery with anastomosis of the left inferior epigastric artery to the left dorsal penile artery. The patient had persistence of severe ED despite patent anastomosis by penile duplex ultrasound. Subsequent arteriography revealed an arterial shunt due to an aberrant obturator artery arising from the donor inferior epigastric artery. The patient underwent embolization of the aberrant obturator artery, with resolution of the shunt and marked improvement in erectile function. The presence of an aberrant obturator artery arising from the inferior epigastric artery may predispose to persistent ED after revascularization due to the creation of a shunt phenomenon. Pelvic arteriography may be useful in identifying anomalous anatomic considerations prior to penile revascularization and to evaluate patients

  13. Determination of the functional significance of coronary artery disease with digital subtraction angiography

    International Nuclear Information System (INIS)

    Mancini, G.B.J.; Hodgson, J.McB.; Le Grand, V.; Vogel, R.A.; Le Free, M.T.; Bates, E.R.; Aueron, F.M.

    1986-01-01

    Imaging of the chambers of the heart, pulmonary circulation and great vessels by intravenous contrast injection was clinically implemented in 1939, but intensive interest in this technique was not generated until relatively recent advances in digital electronics, image intensification, and television technology. Pioneering work from several centers initiated a widespread clinical evaluation of this imaging modality in cardiac diagnosis that was facilitated by commercially available digital angiography systems that provided rudimentary image manipulation techniques. Such image manipulation was also of considerable use in intraarterial applications. The quantitative information inherent in digital images of the heart chambers and coronary arteries sparked a keen interest in using this technology to extract both anatomical and physiological information about patients undergoing cardiac catheterization. This chapter outlines their approach to the use of both intravenous and intraarterial digital techniques in the evaluation of patients requiring cardiac catheterization with a particular emphasis on determination of the functional significance of coronary disease

  14. [Efferent innervation of the arteries of human leptomeninx in arterial hypertension].

    Science.gov (United States)

    Chertok, V M; Kotsiuba, A E; Babich, E V

    2009-01-01

    Structure of the efferent nerve plexuses (adrenergic, acetylcholinestherase- and cholinacetyltranspherase-positive, NO-dependent), was studied in the arteries of human leptomeninx with different diameters. Material was obtained from the corpses of the healthy people and of the patients with initial stages of arterial hypertension (AH). It was shown that the concentrations of cholinergic and adrenergic nerve fibers and varicosities in axon terminal part, innervating the arteries with the diameters ranging from 450 till 100 microm, were not significantly different. In these arteries, NO-ergic plexuses were also detected. In patients with AH, regardless the arterial diameters, the significant increase (up to 15-20%) of adrenergic nerve fiber and varicosity concentrations was found. The changes in cholinergic nerve fiber concentration were found to depend on the vessel diameter: the significant decrease of these parameter was observed only in arteries with the diameter of 100-200 microm. No significant changes in nerve plexus concentration was noticed in the arteries with greater or smaller diameter. In NO-ergic neural conductors, the enzyme activity decreased only in the large arteries, and remained almost unchanged in the small vascular branches. The changes in the vasomotor innervation described in AH, are interpreted as a vasomotor innervation dysfunction of the leptomeninx arteries that may result in the hemodynamic disturbances.

  15. Arterial and venous revascularization with bifurcation of a single central artery: a reliable strategy for Tamai Zone I replantation.

    Science.gov (United States)

    Hsu, Chung-Chen; Lin, Yu-Te; Moran, Steven L; Lin, Cheng-Hung; Wei, Fu-Chan; Lin, Chih-Hung

    2010-12-01

    Replantation of the distal phalanx and pulp can be performed to improve finger function and finger aesthetics; however, establishing adequate venous drainage is a challenge. Slattery et al. reported microsurgical reattachment of a partial distal phalanx with the use of a bifurcated terminal digital artery. The bifurcation was divided into two pedicles, one of which was used for venous drainage. In this article, the authors report their experience with a similar technique and propose a new algorithm for distal finger replantation. From January of 2008 to February of 2009, five replantations were performed using a single central artery. The replanted levels were pulp, avulsed fingertip of the thumb, and distal phalanges. There was no volar vein, dorsal vein, or second artery available in the amputated part for standard venous drainage. Venous drainage in all cases was established by creating an anastomosis from a branch of the solitary terminal artery to a recipient vein. All digits were replanted successfully without evidence of arterial insufficiency or venous congestion. Partial necrosis was not identified postoperatively in any of the five fingers. There were no cases of wound infection. A branch of the central solitary artery may be used successfully to reestablish venous outflow in cases of distal finger tip replantation. This technique allowed for the salvage of all fingers in this study without the use of leeches or other techniques used in cases of venous insufficiency.

  16. Aberrant Ovarian Collateral Originating from External Iliac Artery During Uterine Artery Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Joon Ho; Kim, Man Deuk, E-mail: mdkim@yuhs.ac; Lee, Kwang-hun; Lee, Myungsu; Lee, Mu Sook; Won, Jong Yun; Park, Sung Il; Lee, Do Yun [Yonsei University College of Medicine, Department of Radiology, Research Institute of Radiological Science, Severance Hospital (Korea, Republic of)

    2013-02-15

    We report a case of a 35-year-old woman who underwent uterine artery embolization (UAE) for symptomatic multiple uterine fibroids with collateral aberrant right ovarian artery that originated from the right external iliac artery. We believe that this is the first reported case in the literature of this collateral uterine flow by the right ovarian artery originated from the right external iliac artery. We briefly present the details of the case and review the literature on variations of ovarian artery origin that might be encountered during UAE.

  17. Aberrant Ovarian Collateral Originating from External Iliac Artery During Uterine Artery Embolization

    International Nuclear Information System (INIS)

    Kwon, Joon Ho; Kim, Man Deuk; Lee, Kwang-hun; Lee, Myungsu; Lee, Mu Sook; Won, Jong Yun; Park, Sung Il; Lee, Do Yun

    2013-01-01

    We report a case of a 35-year-old woman who underwent uterine artery embolization (UAE) for symptomatic multiple uterine fibroids with collateral aberrant right ovarian artery that originated from the right external iliac artery. We believe that this is the first reported case in the literature of this collateral uterine flow by the right ovarian artery originated from the right external iliac artery. We briefly present the details of the case and review the literature on variations of ovarian artery origin that might be encountered during UAE.

  18. Arterial compliance in patients with cirrhosis: stroke volume-pulse pressure ratio as simplified index

    DEFF Research Database (Denmark)

    Fuglsang, S; Bendtsen, F; Christensen, E

    2001-01-01

    Arterial function may be altered in patients with cirrhosis. We determined compliance of the arterial tree (C(1)) in relation to systemic and splanchnic hemodynamic derangement and clinical variables. C(1) and the stroke volume-pulse pressure index (SV/PP) were significantly higher (+62% and +40%...... predictors of SV/PP (P abnormalities in the arterial compliance of these patients....

  19. High-Voltage-Input Level Translator Using Standard CMOS

    Science.gov (United States)

    Yager, Jeremy A.; Mojarradi, Mohammad M.; Vo, Tuan A.; Blalock, Benjamin J.

    2011-01-01

    proposed integrated circuit would translate (1) a pair of input signals having a low differential potential and a possibly high common-mode potential into (2) a pair of output signals having the same low differential potential and a low common-mode potential. As used here, "low" and "high" refer to potentials that are, respectively, below or above the nominal supply potential (3.3 V) at which standard complementary metal oxide/semiconductor (CMOS) integrated circuits are designed to operate. The input common-mode potential could lie between 0 and 10 V; the output common-mode potential would be 2 V. This translation would make it possible to process the pair of signals by use of standard 3.3-V CMOS analog and/or mixed-signal (analog and digital) circuitry on the same integrated-circuit chip. A schematic of the circuit is shown in the figure. Standard 3.3-V CMOS circuitry cannot withstand input potentials greater than about 4 V. However, there are many applications that involve low-differential-potential, high-common-mode-potential input signal pairs and in which standard 3.3-V CMOS circuitry, which is relatively inexpensive, would be the most appropriate circuitry for performing other functions on the integrated-circuit chip that handles the high-potential input signals. Thus, there is a need to combine high-voltage input circuitry with standard low-voltage CMOS circuitry on the same integrated-circuit chip. The proposed circuit would satisfy this need. In the proposed circuit, the input signals would be coupled into both a level-shifting pair and a common-mode-sensing pair of CMOS transistors. The output of the level-shifting pair would be fed as input to a differential pair of transistors. The resulting differential current output would pass through six standoff transistors to be mirrored into an output branch by four heterojunction bipolar transistors. The mirrored differential current would be converted back to potential by a pair of diode-connected transistors

  20. [Brain Perfusion, Cognitive Functions, and Vascular Age in Middle Aged Patients With Essential Arterial Hypertension].

    Science.gov (United States)

    Parfenov, V A; Ostroumova, T M; Pеrepelova, E M; Perepelov, V A; Kochetkov, A I; Ostroumova, O D

    2018-05-01

    This study aimed to assess the cognitive functions and cerebral blood flow measured with arterial spin labeling (ASL) and their possible correlations with vascular age in untreated middle-aged patients with grade 1-2 essential arterial hypertension (EAH). We examined 73 subjects aged 40-59 years (33 with EAH and 40 healthy volunteers [controls]). Neuropsychological assessment included Montreal Cognitive Assessment (MoCA), Trail Making test (part A and part B), Stroop Color and Word Test, verbal fluency test (phonemic verbal fluency and semantic verbal fluency), 10‑item word list learning task. All subjects underwent brain MRI. MRI protocol included ASL. Vascular age was calculated by two techniques - using Framingham Heart Study risk tables and SCORE project scales. Patients with EAH had lower performance on phonemic verbal fluency test and lower mean MoCA score (29.2±1.4 vs. 28.1±1.7 points) compared to controls (13.4±3.2, р=0.002; 29.2±1.4, p=0.001, respectively). White matter hyperintensities (WMH) were present in 7.5 % controls and in 51.5 % EAH patients (р=0.0002). Cerebral blood flow (CBF) in EAH patients was lower in both right (39.1±5.6 vs. 45.8±3.2 ml / 100 g / min) and left frontal lobes of the brain (39.2±6.2 и 45.2±3.6 ml / 100 g / min, respectively) compared to controls (р.